WorldWideScience

Sample records for periosteal circumference pc

  1. Periostitis ossificans.

    Science.gov (United States)

    VanDoorne, I; Soubry, R; Wackens, G; Goossens, A

    1995-09-01

    Mandibular periostitis ossificans was assessed in a 18-year-old black boy. This form of chronic osteomyelitis (Garré osteomyelitis) resulted from a periostitis on the 4.8 in association with an infected and ankylosed 4.7. Clinically a firm swelling of the right mandibular angle was noticeable. The diagnosis was confirmed by computed tomography and biopsy. After extraction of the causative teeth, in combination with an antibiotic treatment, a good evolution was obtained. The possible pathogenesis and the differential diagnosis are discussed.

  2. Periosteal osteoblastoma of the distal femur

    Energy Technology Data Exchange (ETDEWEB)

    Nakatani, Tetsuya; Yamamoto, Tetsuji; Akisue, Toshihiro; Marui, Takashi; Hitora, Toshiaki; Kawamoto, Teruya; Nagira, Keiko; Yoshiya, Shinichi; Kurosaka, Masahiro [Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe (Japan); Fujita, Ikuo; Matsumoto, Keiji [Department of Orthopaedic Surgery, Hyogo Medical Center for Adults, Akashi, Hyogo (Japan)

    2004-02-01

    Osteoblastomas located on the surface of the cortical bone, so-called periosteal osteoblastomas, are extremely rare. We report on a case of periosteal osteoblastoma arising from the posterior surface of the right distal femur in a 17-year-old man. Roentgenographic, computed tomographic, magnetic resonance imaging, and histologic features of the case are presented. Periosteal osteoblastoma should be radiologically and histologically differentiated from myositis ossificans, avulsive cortical irregularity syndrome, osteoid osteoma, parosteal osteosarcoma, periosteal osteosarcoma, and high-grade surface osteosarcoma. Although periosteal osteoblastoma is rare, this tumor should be included in the differential diagnosis of surface-type bone tumors. (orig.)

  3. Periosteal osteosarcoma: A case report

    Directory of Open Access Journals (Sweden)

    Errol U. Hutagalung

    2003-09-01

    Full Text Available Periosteal osteosarcoma is a rare type of malignant bone neoplasm, with predominantly cartilaginous component and arising on the bone surface. Reports of the case in the literature were rare. Last case was reported by Mayo Clinic in 1999. We report a case of periosteal osteosarcoma in a 17-year-old male, who was treated surgically with a limb salvage procedure, neoadjuvant and adjuvant chemotherapy were also given to the patient. There was no local recurrence and lung metastases up to 14 months after surgery. (Med J Indones 2003; 12: 166-70 Keywords: osteosarcoma, periosteal osteosarcoma, limb salvage

  4. Periosteal anomaly in osteosarcoma: the imaging findings and its pathological basis

    International Nuclear Information System (INIS)

    Chen Yingming; Meng Quanfei; Jiang Bo; Ma Ling; Lai Yingrong

    2008-01-01

    Objective: To summarize the types and imaging features of periosteal anomaly in osteosmcoma. Further to seek the feature of genesis and advancement of periosteal anomaly and its clinical significance. Methods: One hundred and twenty-eight patients with osteosarcoma were enrolled in this study, which consisted of 76 males and 52 females aging from 5 to 66 years old with an average of 19 years. Both x-ray plain film and MR images were obtained in all patients, and DWI were done in 23 patients. CT scanning was conducted in 48 patients, which included post-contrast scanning done in 36. The pathological gross specimen, macrosection and point-to-point microsection were obtained in each of 14 cases to correlate the imaging findings of periosteal anomaly to the pathological outcome. Results: The imaging and pathological finding: (1) Periosteodema, occurring in 96 patients. The sign was merely demonstratable on MR image and presented as loosened periosteal structure with no tumoral infiltration pathologically. (2) Periosteal lift and thickening, demonstratable on both CT and MR image, including 13 noted on CT and 42 on MR image. Pathologically, non-tumoral infiltration was noted in the thickened periosteum. (3) Periosteal destruction, occurring in 48 patients. Periosteal destruction was merely demonstratable on MR image and presented as localized or generalized tumoral infiltration of the periosteum. (4) Linear periosteal neo-bone formation, demonstrated in 42 cases on plain films, 13 cases on CT and 22 on MR images, respectively. The linear periosteal neo-bone formation was pathologically regularly arranged periosteal neo-bone. (5) Laminar periosteal neo-bone fomation, demonstrated in 21 cases on plain films, 6 cases on CT and 21 on MR images, respectively. Pathologically, it appeared as multi-layer arrangement. (6) Radiated and spiculate periosteal neo-bone formation, demonstrated in 13 cases on plain films, 7 cases on CT and 14 on MR images, respectively. On both plain

  5. Periosteal ganglion

    International Nuclear Information System (INIS)

    Kolar, J.; Zidkova, H.; Matejovsky, Z.

    1986-01-01

    Ganglionic cysts are a common myxomatous degenerative disorder in periarticular connective tissues particularly in the hand and foot as well as within the subchondral bone adjacent to osteoarthritic joints. Compared with them, periosteal ganglia are only rarely reported in the literature. Their radiologic features are quite typical as documented by the following observation. (orig.) [de

  6. Magnetic resonance imaging in the evaluation of periosteal reactions

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira-Barbosa, Marcello Henrique; Trad, Clovis Simao; Muglia, Valdair Francisco; Elias Junior, Jorge; Simao, Marcelo Novelino, E-mail: marcello@fmrp.usp.b [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Sa, Jose Luiz de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas; Oliveira, Rodrigo Cecilio Vieira de [Clinica de Diagnostico por Imagem Tomoson, Aracatuba, SP (Brazil); Engel, Edgard Eduard [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Dept. de Biomecanica, Medicina e Reabilitacao do Aparelho Locomotor

    2010-07-15

    The objective of the present essay was to encourage a careful evaluation of periosteal reactions on magnetic resonance images. The initial approach to bone lesions is made by conventional radiography and, based on the imaging findings, periosteal reactions are classified into classical subtypes. Although magnetic resonance imaging is considered as the gold standard for local staging of bone tumors, the utilization of such method in the study of periosteal reactions related to focal bone lesions has been poorly emphasized, with relatively few studies approaching this subject. The literature review revealed a study describing an experimental animal model of osteomyelitis suggesting that magnetic resonance imaging is superior to other imaging methods in the early identification of periosteal reactions. Another study has suggested a good correlation between conventional radiography and magnetic resonance imaging in the identification and classification of periosteal reactions in cases of osteosarcoma. The present essay illustrates cases of periosteal reactions observed at magnetic resonance imaging in correlation with findings of conventional radiography or other imaging methods. (author)

  7. Magnetic resonance imaging in the evaluation of periosteal reactions

    International Nuclear Information System (INIS)

    Nogueira-Barbosa, Marcello Henrique; Trad, Clovis Simao; Muglia, Valdair Francisco; Elias Junior, Jorge; Simao, Marcelo Novelino; Engel, Edgard Eduard

    2010-01-01

    The objective of the present essay was to encourage a careful evaluation of periosteal reactions on magnetic resonance images. The initial approach to bone lesions is made by conventional radiography and, based on the imaging findings, periosteal reactions are classified into classical subtypes. Although magnetic resonance imaging is considered as the gold standard for local staging of bone tumors, the utilization of such method in the study of periosteal reactions related to focal bone lesions has been poorly emphasized, with relatively few studies approaching this subject. The literature review revealed a study describing an experimental animal model of osteomyelitis suggesting that magnetic resonance imaging is superior to other imaging methods in the early identification of periosteal reactions. Another study has suggested a good correlation between conventional radiography and magnetic resonance imaging in the identification and classification of periosteal reactions in cases of osteosarcoma. The present essay illustrates cases of periosteal reactions observed at magnetic resonance imaging in correlation with findings of conventional radiography or other imaging methods. (author)

  8. Concurrent periosteal chondroma and enchondroma of the fibula mimicking chondrosarcoma

    International Nuclear Information System (INIS)

    Yamamoto, Yasuhiro; Washimi, Osuke; Yamada, Harumoto; Washimi, Yuki; Itoh, Masato; Kuroda, Makoto

    2006-01-01

    We present a rare concurrence of enchondroma and periosteal chondroma in the right distal fibula that mimicked chondrosarcoma in a 13-year-old boy. Radiographs and CT scans showed a periosteal lesion producing saucerization without periosteal reaction and calcification in the distal metaphysis of the right fibula. MRI showed an intramedullary lesion adjacent to the periosteal lesion, although it was invisible at CT. There was no cortical breach on imaging and gross examination. Because both lesions represented benign cartilaginous tumors on histology, concurrent periosteal chondroma and enchondroma of the fibula was diagnosed. This combination in the same bone in a patient without enchondromatosis is exceedingly rare. Such imaging features may be confused with those of chondrosarcoma. (orig.)

  9. Concurrent periosteal chondroma and enchondroma of the fibula mimicking chondrosarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Yasuhiro; Washimi, Osuke; Yamada, Harumoto; Washimi, Yuki; Itoh, Masato [Fujita Health University, Department of Orthopedic Surgery, Toyoake City, Aichi (Japan); Kuroda, Makoto [Fujita Health University, Department of Pathology, Toyoake City, Aichi (Japan)

    2006-05-15

    We present a rare concurrence of enchondroma and periosteal chondroma in the right distal fibula that mimicked chondrosarcoma in a 13-year-old boy. Radiographs and CT scans showed a periosteal lesion producing saucerization without periosteal reaction and calcification in the distal metaphysis of the right fibula. MRI showed an intramedullary lesion adjacent to the periosteal lesion, although it was invisible at CT. There was no cortical breach on imaging and gross examination. Because both lesions represented benign cartilaginous tumors on histology, concurrent periosteal chondroma and enchondroma of the fibula was diagnosed. This combination in the same bone in a patient without enchondromatosis is exceedingly rare. Such imaging features may be confused with those of chondrosarcoma. (orig.)

  10. Diagnostic imaging of tibial periosteal ganglion

    International Nuclear Information System (INIS)

    Valls, R.; Melloni, P.; Darnell, A.; Munoz, J.; Canalies, J.

    1997-01-01

    A case of a soft tissue tumor situated in the anterior surface of the proximal end of the tibia in an adult patient is demonstrated by conventional radiographs, CT, and MRI. The lesion was well defined with respect to the adjacent soft tissue. The CT exam showed a soft tissue mass with external cortical erosion and thick spicules by periosteal reaction. On T1-weighted images the mass was homogeneous and of low signal intensity, whereas on T2-weighted images it showed a high signal intensity, with some septa in the mass. The differential considerations include a periosteal chondroma, a lipoma, a subperiosteal hematoma, an inflammatory process, a giant cell tumor of tendon sheath, and a parosteal osteosarcoma. The CT and MR features of these entities are reviewed as an aid in differential diagnosis of the periosteal ganglion. (orig.). With 4 figs

  11. Radiological features of 24 periosteal chondrosarcomas

    International Nuclear Information System (INIS)

    Vanel, D.; De Paolis, M.; Mercuri, M.; Monti, C.; Picci, P.

    2001-01-01

    Objective. To report the imaging findings of 24 periosteal chondrosarcomas diagnosed, staged, treated and followed in a single institution, to analyze and define their pattern, and discuss their practical consequences.Design and patients. Plain films, 16 CT examinations and four MRI examinations were reviewed, and compared with the histological evaluation.Results. There were 20 men and four women, aged from 17 to 65 years. Twelve lesions involved the distal femoral metaphyses (8 posteriorly), five the proximal humerus, two the proximal metaphyses of the femur and two of the tibia, two the humeral shafts and one the iliac wing. Size varied from 4 to 11 cm. The cortex was always involved (thick, 15; thin, 13). Typical cartilaginous calcifications and cartilaginous lobules were very frequent. Radial thick periosteal bone formations (n=6) indicated calcifications between the lobules of cartilage. Medullary involvement was rare (n=2). All patients are alive and free of disease.Conclusions. Recognizing periosteal chondrosarcoma is of paramount importance because the prognosis is excellent after adequate local surgery alone. The patterns of other surface tumors of bone are usually different. (orig.)

  12. Reactive Periostitis from Inhalant Abuse.

    Science.gov (United States)

    Hock, Lauren E; Honkanen, Iiro; Fiordellisi, Wendy; Bettendorf, Brittany

    2018-04-16

    The patient, a 36-year-old woman, presented with a 6-week history of swollen hands and fingers and associated arthralgia. She had a history of polysubstance abuse. The arthralgia and swelling started one month after she began inhaling two cans of "Dust-Off" (1,1-difluoroethane) daily. Physical examination revealed tender proximal and middle phalanges of all fingers bilaterally with bulbous appearance (A). There was no clubbing. Radiography of the hands revealed diffuse reactive periostitis with discrete layering of periosteal bone formation without bony destruction (B). TSH was normal. Serum alkaline phosphatase was 854 U/L. Computed tomography of the chest, abdomen, and pelvis showed no evidence of malignancy or pulmonary disease This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. Isolated periostitis as a manifestation of systemic vasculitis in a child: imaging features

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Jung-Eun; Kim, In-One; Kim, Woo Sun; Yeon, Kyung Mo [Seoul National University College of Medicine and the Institute of Radiation Medicine, Department of Radiology, 101 Daehang-ro Jongro-gu, Seoul (Korea, Republic of)

    2010-12-15

    We report a case of isolated periostitis associated with Takayasu arteritis in a 10-year-old boy presenting with calf pain. Radiographs revealed a localized, thick periosteal reaction with irregular margin in the proximal left fibula. MRI revealed irregular thickening with enhancement of the periosteum in the proximal fibula and heterogeneous enhancement along vascular bundles in the calf. Isolated periostitis is a rare skeletal manifestation of systemic vasculitis that could be misdiagnosed as neoplastic or traumatic periosteal reaction. (orig.)

  14. Periosteal reaction in systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Glickstein, M.; Neustadter, L.; Dalinka, M.; Kricun, M.

    1986-01-01

    The authors report three patients with systemic lupus erythematosus and periosteal reaction. Two of the three cases had systemic vasculitis and the third had local ischemia with ischemic necrosis. (orig.)

  15. Bilateral metachronous periosteal tibial amyloid tumors

    International Nuclear Information System (INIS)

    Murata, H.; Kusuzaki, Katsuyuki; Hashiguchi, S.; Ueda, Hidetaka; Hirasawa, Yasusuke

    2000-01-01

    Localized primary periosteal amyloid tumors are extremely rare. A case of bilateral tibial amyloid tumor is presented. A 62-year-old woman initially presented with a painful mass in the anterior aspect of the right leg. There was no evidence of underlying systemic disease, including chronic infection or malignancy. Based on the results of resistance with Congo red staining to treatment with potassium permanganate and positivity for kappa light chain, we classified this particular case as AL-type amyloidosis. The patient noticed a swelling in the opposite leg 2 years later. The second tumor was also an AL-type amyloidoma. Amyloid tumors are generally solitary. This is the first case of bilateral periosteal amyloid tumors of the AL-type occurring in the tibiae. (orig.)

  16. [Magnetic resonance imaging of tibial periostitis].

    Science.gov (United States)

    Meyer, X; Boscagli, G; Tavernier, T; Aczel, F; Weber, F; Legros, R; Charlopain, P; Martin, J P

    1998-01-01

    Tibial periostitis frequently occurs in athletes. We present our experience with MRI in a series of 7 patients (11 legs) with this condition. The clinical presentation and scintigraphic scanning suggested the diagnosis. MRI exploration of 11 legs demonstrated a high band-like juxta-osseous signal enhancement of SE and IR T2 weighted sequences in 6 cases, a signal enhancement after i.v. contrast administration in 4. Tibial periostitis is a clinical diagnosis and MRI and scintigraphic findings can be used to assure the differential diagnosis in difficult cases with stress fracture. MRI can visualize juxta-osseous edematous and inflammatory reactions and an increased signal would appear to be characteristic when the band-like image is fixed to the periosteum.

  17. Spontaneous mutation of Dock7 results in lower trabecular bone mass and impaired periosteal expansion in aged female Misty mice.

    Science.gov (United States)

    Le, Phuong T; Bishop, Kathleen A; Maridas, David E; Motyl, Katherine J; Brooks, Daniel J; Nagano, Kenichi; Baron, Roland; Bouxsein, Mary L; Rosen, Clifford J

    2017-12-01

    Misty mice (m/m) have a loss of function mutation in Dock7 gene, a guanine nucleotide exchange factor, resulting in low bone mineral density, uncoupled bone remodeling and reduced bone formation. Dock7 has been identified as a modulator of osteoblast number and in vitro osteogenic differentiation in calvarial osteoblast culture. In addition, m/m exhibit reduced preformed brown adipose tissue innervation and temperature as well as compensatory increase in beige adipocyte markers. While the low bone mineral density phenotype is in part due to higher sympathetic nervous system (SNS) drive in young mice, it is unclear what effect aging would have in mice homozygous for the mutation in the Dock7 gene. We hypothesized that age-related trabecular bone loss and periosteal envelope expansion would be altered in m/m. To test this hypothesis, we comprehensively characterized the skeletal phenotype of m/m at 16, 32, 52, and 78wks of age. When compared to age-matched wild-type control mice (+/+), m/m had lower areal bone mineral density (aBMD) and areal bone mineral content (aBMC). Similarly, both femoral and vertebral BV/TV, Tb.N, and Conn.D were decreased in m/m while there was also an increase in Tb.Sp. As low bone mineral density and decreased trabecular bone were already present at 16wks of age in m/m and persisted throughout life, changes in age-related trabecular bone loss were not observed highlighting the role of Dock7 in controlling trabecular bone acquisition or bone loss prior to 16wks of age. Cortical thickness was also lower in the m/m across all ages. Periosteal and endosteal circumferences were higher in m/m compared to +/+ at 16wks. However, endosteal and periosteal expansion were attenuated in m/m, resulting in m/m having lower periosteal and endosteal circumferences by 78wks of age compared to +/+, highlighting the critical role of Dock7 in appositional bone expansion. Histomorphometry revealed that osteoblasts were nearly undetectable in m/m and marrow

  18. Periosteal Ewing's Sarcoma: Report of Two New Cases and Review of the Literature

    OpenAIRE

    Kollender, Yehuda; Shabat, Shay; Nirkin, Alexander; Issakov, Josephine; Flusser, Gideon; Merimsky, Ofer; Meller, Isaac

    1999-01-01

    Background. The origin of Ewing's sarcoma in a periosteal location is rare and not clearly documented. Other malignant bone tumors appear to have a somewhat better prognosis when confined between periosteum and bone. Is it the same for periosteal Ewing's sarcoma? Methods. We describe two new cases and comprehensively review the literature consisting of 18 documented cases since the condition was first described in 1986 (S.M. Bator.Cancer 58:1781– 4). Results. Periosteal Ewing's sarcoma differ...

  19. Periostal hypertrophic osteopathy of bones (long bones) in colitis ulcerosa in adolescents

    International Nuclear Information System (INIS)

    Bargon, G.; Arlart, I.

    1982-01-01

    The article reports on a 14-year old girl with periostal new formation of bones at the long bones of the lower arms, the femora and the lower legs the individual phalanges and metacarpalia after colitis ulcerosa which had lasted for several years and had progressed stagewise. After a clinically recorded new attack the periostal new formations of bone progressed. Some time after the last attack of colitis the periostal changes in the bones partially receded. The article discusses the hypothetic explanations aiming at interpreting the pathogenesis of hypertrophic osteoarthropathies and periostoses, as given in the literature. (orig.) [de

  20. Periostal hypertrophic osteopathy of bones (long bones) in colitis ulcerosa in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Bargon, G.; Arlart, I.

    1982-03-01

    The article reports on a 14-year old girl with periostal new formation of bones at the long bones of the lower arms, the femora and the lower legs the individual phalanges and metacarpalia after colitis ulcerosa which had lasted for several years and had progressed stagewise. After a clinically recorded new attack the periostal new formations of bone progressed. Some time after the last attack of colitis the periostal changes in the bones partially receded. The article discusses the hypothetic explanations aiming at interpreting the pathogenesis of hypertrophic osteoarthropathies and periostoses, as given in the literature.

  1. Periosteal Ewing's Sarcoma: Report of Two New Cases and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Yehuda Kollender

    1999-01-01

    Full Text Available Background. The origin of Ewing's sarcoma in a periosteal location is rare and not clearly documented. Other malignant bone tumors appear to have a somewhat better prognosis when confined between periosteum and bone. Is it the same for periosteal Ewing's sarcoma?

  2. Acute periostitis in early acquired syphilis simulating shin splints in a jogger.

    Science.gov (United States)

    Meier, J L; Mollet, E

    1986-01-01

    Acute periostitis affecting the long bones is a characteristic but uncommon manifestation of syphilis in the adult with an early acquired infection. This report describes the history of a jogger who developed acute localized periostitis of the shaft of both tibiae during the early stage of acquired syphilis. Symptomatology was initially attributed to the medial tibial stress syndrome.

  3. Periostitis secondary to interleukin-11 (Oprelvekin, Neumega). Treatment for thrombocytopenia in pediatric patients

    International Nuclear Information System (INIS)

    Milman, Edward; Berdon, Walter E.; Ruzal-Shapiro, Carrie; Garvin, James H.; Cairo, Mitchell S.; Bessmertny, Olga

    2003-01-01

    Interleukin-11 (Oprelvekin, Neumega) is a newly introduced thrombopoietic growth factor that stimulates production, differentiation, and maturation of megakaryocytes and platelets. Reversible periostitis has been reported as the side effect of the drug in primates and in the phase I/II trials. We report our experience with 5 cases of periostitis, occurring in thrombocytopenic children with three non-malignant and two malignant conditions, out of 24 pediatric patients treated with IL-11 at 75 μg/kg per day for a median of 17 days. The findings were noted in the clavicle or the proximal humerus. Two patients also had forearm and lower-extremity long-bone involvement. All patients had normal bones before IL-11 was given, changes occurred in both non-malignant and malignant diseases, and periostitis disappeared after use of the drug was discontinued. The distribution and appearance of the changes are similar to prostaglandin E1 and hypervitaminosis A. The changes are reversible after termination of treatment and are most noted in younger patients. The exact mechanism is not clear. The detection of periostitis makes it essential for the radiologists to enquire as to what medications patients are receiving. The pediatric doses (75 g/kg/d) are above those recommended for adult patients (50 g/kg/d) and this may account for the pediatric bone changes of periostitis. (orig.)

  4. Paralytic Ectropion Treatment with Lateral Periosteal Flap Canthoplasty and Introduction of the Ectropion Severity Score

    Directory of Open Access Journals (Sweden)

    Steven F. S. Korteweg, MD

    2014-05-01

    Conclusions: The ESS is a useful instrument to score the severity of paralytic ectropion. The periosteal flap canthoplasty is an effective procedure, with durable results in paralytic ectropion patients. The same periosteal flap can be used in a revision procedure.

  5. Case report 518: Periosteal chrondroma of scapula

    Energy Technology Data Exchange (ETDEWEB)

    Rubenstein, D.J.; Harkavy, L.; Glantz, L.

    1989-03-01

    The scapula is a unique location for periosteal chondroma. Despite the unusual location, recognition of the typical radiological features - scalloping and sclerosis of the adjacent cortex, cartilaginous matrix, soft tissue mass and normal bone scan - a correct diagnosis was made preoperatively with confidence. The appropriate treatment of en bloc resection was thus instituted. (orig./GDG).

  6. Does Periosteal Graft Combined With Platelet-Rich Plasma Enhance the Healing of Bone Defect?

    Science.gov (United States)

    Türkseven, Arzu; Özçelik, Derya; Çaliş, Mert; Celik, Hakan Hamdi; Yilmaz, Fahri; Önbaş, Ömer; Vatansever, Alper; Toplu, Gaye

    2018-02-12

    This study investigated the effect of periosteal graft + platelet-rich plasma (PRP) combination on facial bone defect healing. Five-millimeter critical sized defects in zygomatic arches of 12 adult New Zealand rabbits were created. Rabbits were randomly divided into 3 groups: First group (control group): bone defects of left zygomatic arches of 6 rabbits were wrapped with a silicone tube. Second group (periosteal graft group): bone defects of left zygomatic arches of 6 rabbits were wrapped with periosteal graft. Third group (experimental group): bone defects of right zygomatic arches of 12 rabbits were wrapped with periosteal graft-PRP combination. New bone formation was evaluated at 8th and 16th weeks. One rabbit was sacrificed at 8th week. Remaining 11 rabbits were imaged with 3-dimensional computed tomography (CT) at 16th week; then, zygomatic arches were removed for micro-CT and histologic examinations. Three-dimensional CT analysis at 16th week revealed no significant difference between groups regarding new bone formation (P = 0.232). Micro-CT analysis of new regenerated bone at 16th week displayed significant differences between groups 1 and 3 regarding mean bone volume (BV, mm) (P = 0.028) and mean bone mineral density (BMD, mm) (P = 0.001). There was no difference between groups 2 and 3 or between groups 1 and 2, regarding BV or BMD. Histological Bone Regeneration Scorings at 16th week displayed significant difference between groups (P = 0.015). Negative correlation between 3-dimensional CT and histologic results (r = 0.120); positive correlations between BV/BMD values in micro-CT and histologic results (r = 0.524 and r = 0.456) were found. By enhancing bone formation capacity of periosteal grafts, periosteal graft-PRP combination provided bone formation having more volume and density comparing with silicone tube application.

  7. Diagnostic performance of magnetic resonance imaging in the assessment of periosteal reactions in bone sarcomas using conventional radiography as the reference

    Science.gov (United States)

    de Sá Neto, José Luiz; Simão, Marcelo Novelino; Crema, Michel Daoud; Engel, Edgard Eduard; Nogueira-Barbosa, Marcello Henrique

    2017-01-01

    Objective: To evaluate the performance of magnetic resonance imaging (MRI) in detecting periosteal reactions and to compare MRI and conventional radiography (CR) in terms of the classification of periosteal reactions. Materials and Methods: Retrospective study of 42 consecutive patients (mean age, 22 years; 20 men) with a confirmed diagnosis of osteosarcoma or Ewing's sarcoma, MRI and CR images having been acquired pretreatment. Three blinded radiologists detected periosteal reactions and evaluated each periosteal reaction subtype in CR and MRI images: Codman's triangle; laminated; and spiculated. The CR was used as a benchmark to calculate the diagnostic performance. We used the kappa coefficient to assess interobserver reproducibility. A two-tailed Fisher's exact test was used in order to assess contingency between CR and MRI classifications. Results: In the detection of periosteal reactions, MRI showed high specificity, a high negative predictive value, and low-to-moderate sensitivity. For CR and for MRI, the interobserver agreement for periosteal reaction was almost perfect, whereas, for the classification of different subtypes of periosteal reaction, it was higher for the Codman's triangle subtype and lower for the spiculated subtype. There was no significant difference between MRI and CR in terms of the classifications (p < 0.05). Conclusion: We found no difference between MRI and CR in terms of their ability to classify periosteal reactions. MRI showed high specificity and almost perfect interobserver agreement for the detection of periosteal reactions. The interobserver agreement was variable for the different subtypes of periosteal reaction. PMID:28670029

  8. Diagnostic performance of magnetic resonance imaging in the assessment of periosteal reactions in bone sarcomas using conventional radiography as the reference

    Directory of Open Access Journals (Sweden)

    José Luiz de Sá Neto

    Full Text Available Abstract Objective: To evaluate the performance of magnetic resonance imaging (MRI in detecting periosteal reactions and to compare MRI and conventional radiography (CR in terms of the classification of periosteal reactions. Materials and Methods: Retrospective study of 42 consecutive patients (mean age, 22 years; 20 men with a confirmed diagnosis of osteosarcoma or Ewing's sarcoma, MRI and CR images having been acquired pretreatment. Three blinded radiologists detected periosteal reactions and evaluated each periosteal reaction subtype in CR and MRI images: Codman's triangle; laminated; and spiculated. The CR was used as a benchmark to calculate the diagnostic performance. We used the kappa coefficient to assess interobserver reproducibility. A two-tailed Fisher's exact test was used in order to assess contingency between CR and MRI classifications. Results: In the detection of periosteal reactions, MRI showed high specificity, a high negative predictive value, and low-to-moderate sensitivity. For CR and for MRI, the interobserver agreement for periosteal reaction was almost perfect, whereas, for the classification of different subtypes of periosteal reaction, it was higher for the Codman's triangle subtype and lower for the spiculated subtype. There was no significant difference between MRI and CR in terms of the classifications (p < 0.05. Conclusion: We found no difference between MRI and CR in terms of their ability to classify periosteal reactions. MRI showed high specificity and almost perfect interobserver agreement for the detection of periosteal reactions. The interobserver agreement was variable for the different subtypes of periosteal reaction.

  9. Tibial periosteal ganglion cyst: The ganglion in disguise

    Science.gov (United States)

    Reghunath, Anjuna; Mittal, Mahesh K; Khanna, Geetika; Anil, V

    2017-01-01

    Soft tissue ganglions are commonly encountered cystic lesions around the wrist presumed to arise from myxomatous degeneration of periarticular connective tissue. Lesions with similar pathology in subchondral location close to joints, and often simulating a geode, is the less common entity called intraosseous ganglion. Rarer still is a lesion produced by mucoid degeneration and cyst formation of the periostium of long bones, rightly called the periosteal ganglion. They are mostly found in the lower extremities at the region of pes anserinus, typically limited to the periosteum and outer cortex without any intramedullary component. We report the case of a 62 year-old male who presented with a tender swelling on the mid shaft of the left tibia, which radiologically suggested a juxtacortical lesion extending to the soft tissue or a soft tissue neoplasm eroding the bony cortex of tibia. It was later diagnosed definitively as a periosteal ganglion in an atypical location, on further radiologic work-up and histopathological correlation. PMID:28515597

  10. Failure of isolated rat tibial periosteal cells to 5 alpha reduce testosterone to 5 alpha-dihydrotestosterone

    International Nuclear Information System (INIS)

    Turner, R.T.; Bleiberg, B.; Colvard, D.S.; Keeting, P.E.; Evans, G.; Spelsberg, T.C.

    1990-01-01

    Periosteal cells were isolated from tibiae of adult male rats after collagenase treatment. Northern blot analysis of total cytoplasmic RNA extracted from the isolated periosteal cells was positive for expression of genes encoding the osteoblast marker proteins osteocalcin (BGP) and pre-pro-alpha 2(I) chain of type 1 precollagen. The isolated periosteal cells were incubated with 1 nM [3H]testosterone [( 3 H]T) for up to 240 minutes and the reaction products separated by high-performance liquid chromatography. [ 3 H]5 alpha-dihydrotestosterone [( 3 H]DHT) was not detected in extracts of periosteal cell incubations. In contrast, [ 3 H]DHT was produced in a time-dependent manner by cells from seminal vesicles. These results suggest that testosterone 5 alpha-reductase activity is not expressed by osteoblasts in rat tibial periosteum and that the anabolic effects of androgens in this tissue are not mediated by locally produced DHT

  11. Brachialis periosteal avulsion injury: case report with magnetic resonance imaging findings

    International Nuclear Information System (INIS)

    Lam, Justin Chak Yiu; Lee, Ka Lok Ryan; Griffith, James F.

    2016-01-01

    Brachialis periosteal avulsion injury is an uncommon injury occurring in young children. The injury may be misinterpreted or overlooked because of misleading or subtle radiological findings. A case of 7-year-old child with post-traumatic elbow pain and subtle findings on elbow radiography is presented. The injury was initially misinterpreted as an avulsion fracture of the medial epicondyle. Following radiological review, a diagnosis of brachialis periosteal avulsion injury was made. The radiographic and magnetic resonance imaging (MRI) findings of this injury are presented to stress the value of comparing the radiographic findings with previous imaging and to increase awareness of this uncommon injury. (orig.)

  12. Brachialis periosteal avulsion injury: case report with magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Lam, Justin Chak Yiu; Lee, Ka Lok Ryan; Griffith, James F. [Prince of Wales Hospital, Department of Imaging and Interventional Radiology, Shatin, N.T (China)

    2016-11-15

    Brachialis periosteal avulsion injury is an uncommon injury occurring in young children. The injury may be misinterpreted or overlooked because of misleading or subtle radiological findings. A case of 7-year-old child with post-traumatic elbow pain and subtle findings on elbow radiography is presented. The injury was initially misinterpreted as an avulsion fracture of the medial epicondyle. Following radiological review, a diagnosis of brachialis periosteal avulsion injury was made. The radiographic and magnetic resonance imaging (MRI) findings of this injury are presented to stress the value of comparing the radiographic findings with previous imaging and to increase awareness of this uncommon injury. (orig.)

  13. Failure of isolated rat tibial periosteal cells to 5 alpha reduce testosterone to 5 alpha-dihydrotestosterone

    Energy Technology Data Exchange (ETDEWEB)

    Turner, R.T.; Bleiberg, B.; Colvard, D.S.; Keeting, P.E.; Evans, G.; Spelsberg, T.C. (Mayo Clinic, Rochester, MN (USA))

    1990-07-01

    Periosteal cells were isolated from tibiae of adult male rats after collagenase treatment. Northern blot analysis of total cytoplasmic RNA extracted from the isolated periosteal cells was positive for expression of genes encoding the osteoblast marker proteins osteocalcin (BGP) and pre-pro-alpha 2(I) chain of type 1 precollagen. The isolated periosteal cells were incubated with 1 nM (3H)testosterone (({sup 3}H)T) for up to 240 minutes and the reaction products separated by high-performance liquid chromatography. ({sup 3}H)5 alpha-dihydrotestosterone (({sup 3}H)DHT) was not detected in extracts of periosteal cell incubations. In contrast, ({sup 3}H)DHT was produced in a time-dependent manner by cells from seminal vesicles. These results suggest that testosterone 5 alpha-reductase activity is not expressed by osteoblasts in rat tibial periosteum and that the anabolic effects of androgens in this tissue are not mediated by locally produced DHT.

  14. Primary periosteal lymphoma - rare and unusual

    Energy Technology Data Exchange (ETDEWEB)

    Abdelwahab, Ibrahim F. [Coney Island Hospital, Department of Radiology, New York, NY (United States); Hoch, Benjamin [Mount Sinai School of Medicine, CUNY, Department of Pathology, New York, NY (United States); Hermann, George [Mount Sinai School of Medicine, CUNY, Department of Radiology, New York, NY (United States); Bianchi, Stefano [Clinique et Fondation des Grangettes, Geneva (Switzerland); Klein, Michael J. [UAB School of Medicine, Department of Pathology, Birmingham, AL (United States); Springfield, Dempsey S. [Mount Sinai School of Medicine, CUNY, Department of Orthopedics, New York, NY (United States)

    2007-04-15

    We describe a primary periosteal lymphoma that involved only the periosteum without affecting the adjacent medulla or the regional lymph nodes. No other lymphomatous foci were found in either the distant lymph nodes or viscera. This unusual presentation simulates the imaging appearance of surface lesions of bone, namely benign and malignant tumors, and departs from the typical appearance of primary lymphoma of bone. Therefore, this rare type of lymphoma should be considered in the differential diagnosis of surface bone lesions. (orig.)

  15. Massive florid reactive periostitis

    International Nuclear Information System (INIS)

    Nance, K.V.; Renner, J.B.; Brashear, H.R.; Siegal, G.P.; North Carolina Univ., Chapel Hill, NC

    1990-01-01

    Florid reactive periostitis is a rare, benign process usually occurring in the small, tubular bones of the hands and feet. Typically the lesion occurs in an adolescent or young adult and presents as a small area of pain and erythema over the affected bone. Although the histologic features may suggest malignancy, there is usually little radiographic evidence to support such a diagnosis. In the following report an unusual example of this entity is described whose large size and relentless local progression led to initial diagnostic uncertainty and eventual aggressive management. This case suggests that a wide spectrum of radiologic and morphologic changes may be seen in this entity and that a seemingly unrelated genetic disease may alter the typical clinical course. (orig.)

  16. Primary periosteal lymphoma: an unusual presentation of non-Hodgkin's lymphoma with radiographic, MR imaging, and pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Scot E.; Beall, Douglas P.; Sanders, Timothy G. [Department of Radiology, Wilford Hall Medical Center, 759th MDTS/MTRD, 2200 Bergquist Drive, Suite 1, Lackland AFB, TX 78236-5300 (United States); Filzen, Timothy W.; Parsons, Theodore W. [Department of Orthopedic Surgery, Wilford Hall Medical Center, 59th MDW/MCSO, 2200 Bergquist Drive, Suite 1, Lackland AFB, TX 78236-5300 (United States); Bezzant, Shane M. [Department of Radiology, Brooke Army Medical Center, 3851 Roger Brooke Drive, Bldg 3600, Fort Sam Houston, TX 78234-6200 (United States); Burton, Mark P. [Department of Pathology, Wilford Hall Medical Center, 59th MDW/MTLP, 2200 Bergquist Drive, Suite 1, Lackland AFB, TX 78236-5300 (United States)

    2003-04-01

    This report describes a primary periosteal location of non-Hodgkin's lymphoma, without nodal disease, and without adjacent intramedullary disease at presentation. The clinical and imaging appearance of periosteal lymphoma simulates other neoplastic osseous surface tumors more than that of lymphoma in other locations. Consideration of this rare presentation of non-Hodgkin's lymphoma in the differential diagnosis of periosteal bone lesions can be helpful to ensure proper diagnosis and treatment. (orig.)

  17. Periostitis and osteomyelitis in chronic drug addicts

    International Nuclear Information System (INIS)

    Taylor, C.R.; Lawson, J.P.

    1986-01-01

    Periostitis and osteomyelitis can occur in drug addicts not only by hematogeneous dissemination of the infecting organisms, but as a result of introduction of bacteria by direct injection into periosteum or injection through infected skin and subcutaneous tissues. A spectrum of examples of osteomyelitis of the bones of the forearm in drug addicts is presented to illustrate this phenomenon. Neglect of these infections and the trauma of continued injections can lead to extensive tissue and bone loss. (orig.)

  18. Case report 480: Periosteal amyloid tumor

    International Nuclear Information System (INIS)

    Yoshida, S.O.; Karjoo, R.; Johnstone, M.R.

    1988-01-01

    In summary, a 66-year-old woman presented with an asymptomatic left pretibial tumor of 7 years duration. Serial radiographs over this period demonstrated a slowly enlarging periosteal tumor with focal and increasing calcifications/ossifications. No involvement of the underlying medullary bone, as demonstrated by computed tomography was noted. Following the diagnosis by biopsy of an amyloid tumor, serum and urine electrophoreses, complete blood count, SMAC panel, erythrocyte sedimentation rate, and serum rheumatoid factor level were found to be within reference ranges. A needle biopsy of the abdominal wall failed to reveal amyloid in the fat by Congo-red staining. (orig.)

  19. Periosteal chondrosarcoma in a 9-year-old girl with osteochondromatosis

    Energy Technology Data Exchange (ETDEWEB)

    Weinberg, Jacob [Schneider Children' s Hospital, Division of Pediatric Orthopaedic Surgery, New York (United States); New York University/Hospital for Joint Diseases, Division of Orthopaedic Oncology, New York, New York (United States); Miller, Theodore T. [North Shore University Hospital, Department of Radiology, Manhasset, New York (United States); Handelsman, John E.; Godfried, David H. [Schneider Children' s Hospital, Division of Pediatric Orthopaedic Surgery, New York (United States); Kahn, Leonard B. [Long Island Jewish Medical Center, Department of Pathology, New Hyde Park, New York (United States); Kenan, Samuel [Schneider Children' s Hospital, Division of Pediatric Orthopaedic Surgery, New York (United States); Children' s Hospital Boston, Department of Orthopaedic Surgery, Boston, Massachusetts (United States)

    2005-09-01

    A 9-year-old girl with multiple osteochondromatosis presented with a 1 year history of a gradually enlarging surface lesion originating from the midsection of the right humerus, distal to an osteochondroma. Radiographically and histologically this lesion proved to be a periosteal chondrosarcoma adjacent to an osteochondroma. (orig.)

  20. Periosteal chondrosarcoma: a histopathological and molecular analysis of a rare chondrosarcoma subtype.

    Science.gov (United States)

    Cleven, Arjen H G; Zwartkruis, Evita; Hogendoorn, Pancras C W; Kroon, Herman M; Briaire-de Bruijn, Inge; Bovée, Judith V M G

    2015-10-01

    Periosteal chondrosarcoma is a rare, malignant cartilage-forming neoplasm originating from the periosteal surface of bone. We collected 38 cases from the archives of the Netherlands Committee on Bone Tumours, with the aim of studying histological features and evaluating the involvement of isocitrate dehydrogenase 1 (IDH1), EXT, Wnt/β-catenin, the pRB pathway (CDK4 and p16), and the TP53 pathway (p53 and MDM2). Histology showed a moderately cellular matrix with mucoid-myxoid changes and, in 42% of cases, formation of a neocortex. Occasional intramedullary extension (26%) and subsequent host bone entrapment (40%) were seen. Histological grading revealed grade 1 (53%) and grade 2 (45%). The EXT1 protein was normally expressed, and mutations in IDH1 were observed in only 15% of cases. pRb signalling was deregulated by loss of p16 expression in 50% of cases, and Wnt signalling was lost in 89%. No alterations were found in CDK4, p53, or MDM2. We report the first large histological and molecular study on periosteal chondrosarcoma showing that histopathological examination and molecular aberrations do not predict prognosis. Although the mutation frequency of IDH1 was low, we confirm the supposed relationship with central chondrosarcoma. Moreover, we identify loss of canonical Wnt signalling and deregulation of pRb signalling as possible events contributing to its histogenesis. © 2015 John Wiley & Sons Ltd.

  1. The presentation, treatment and outcome of periosteal chondrosarcoma in the Netherlands

    NARCIS (Netherlands)

    Goedhart, L. M.; Ploegmakers, J. J. W.; Kroon, H. M.; Zwartkruis, E. C. H.; Jutte, P. C.

    In this case study, we describe the clinical presentation and treatment of 36 patients with periosteal chondrosarcoma collected over a 59-year period by the archive of the Netherlands Committee on Bone Tumours. The demographics, clinical presentation, radiological features, treatment and follow-up

  2. A Modified Rabbit Ulna Defect Model for Evaluating Periosteal Substitutes in Bone Engineering: A Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    El Backly, Rania M. [DIMES, University of Genova, Genova (Italy); IRCCS AOU San Martino–IST Istituto Nazionale per la Ricerca sul Cancro, Genova (Italy); Faculty of Dentistry, Alexandria University, Alexandria (Egypt); Chiapale, Danilo [IRCCS AOU San Martino–IST Istituto Nazionale per la Ricerca sul Cancro, Genova (Italy); Muraglia, Anita [Biorigen S.R.L., Genova (Italy); Tromba, Giuliana [Sincrotrone Trieste S.C.P.A., Trieste (Italy); Ottonello, Chiara [Biorigen S.R.L., Genova (Italy); Santolini, Federico [IRCCS AOU San Martino–IST Istituto Nazionale per la Ricerca sul Cancro, Genova (Italy); Cancedda, Ranieri; Mastrogiacomo, Maddalena, E-mail: maddalena.mastrogiacomo@unige.it [DIMES, University of Genova, Genova (Italy); IRCCS AOU San Martino–IST Istituto Nazionale per la Ricerca sul Cancro, Genova (Italy)

    2015-01-06

    The present work defines a modified critical size rabbit ulna defect model for bone regeneration in which a non-resorbable barrier membrane was used to separate the radius from the ulna to create a valid model for evaluation of tissue-engineered periosteal substitutes. Eight rabbits divided into two groups were used. Critical defects (15 mm) were made in the ulna completely eliminating periosteum. For group I, defects were filled with a nanohydroxyapatite poly(ester urethane) scaffold soaked in PBS and left as such (group Ia) or wrapped with a tissue-engineered periosteal substitute (group Ib). For group II, an expanded-polytetrafluoroethylene (e-PTFE) (GORE-TEX{sup ®}) membrane was inserted around the radius then the defects received either scaffold alone (group IIa) or scaffold wrapped with periosteal substitute (group IIb). Animals were euthanized after 12–16 weeks, and bone regeneration was evaluated by radiography, computed microtomography (μCT), and histology. In the first group, we observed formation of radio-ulnar synostosis irrespective of the treatment. This was completely eliminated upon placement of the e-PTFE (GORE-TEX{sup ®}) membrane in the second group of animals. In conclusion, modification of the model using a non-resorbable e-PTFE membrane to isolate the ulna from the radius was a valuable addition allowing for objective evaluation of the tissue-engineered periosteal substitute.

  3. A Modified Rabbit Ulna Defect Model for Evaluating Periosteal Substitutes in Bone Engineering: A Pilot Study

    International Nuclear Information System (INIS)

    El Backly, Rania M.; Chiapale, Danilo; Muraglia, Anita; Tromba, Giuliana; Ottonello, Chiara; Santolini, Federico; Cancedda, Ranieri; Mastrogiacomo, Maddalena

    2015-01-01

    The present work defines a modified critical size rabbit ulna defect model for bone regeneration in which a non-resorbable barrier membrane was used to separate the radius from the ulna to create a valid model for evaluation of tissue-engineered periosteal substitutes. Eight rabbits divided into two groups were used. Critical defects (15 mm) were made in the ulna completely eliminating periosteum. For group I, defects were filled with a nanohydroxyapatite poly(ester urethane) scaffold soaked in PBS and left as such (group Ia) or wrapped with a tissue-engineered periosteal substitute (group Ib). For group II, an expanded-polytetrafluoroethylene (e-PTFE) (GORE-TEX ® ) membrane was inserted around the radius then the defects received either scaffold alone (group IIa) or scaffold wrapped with periosteal substitute (group IIb). Animals were euthanized after 12–16 weeks, and bone regeneration was evaluated by radiography, computed microtomography (μCT), and histology. In the first group, we observed formation of radio-ulnar synostosis irrespective of the treatment. This was completely eliminated upon placement of the e-PTFE (GORE-TEX ® ) membrane in the second group of animals. In conclusion, modification of the model using a non-resorbable e-PTFE membrane to isolate the ulna from the radius was a valuable addition allowing for objective evaluation of the tissue-engineered periosteal substitute.

  4. Periosteal chondroma with spinal cord compression in the thoracic spinal canal: a case report

    International Nuclear Information System (INIS)

    Kang, Dong Hyeok; Kang, Byeong Seong; Kwon, Woon Jung; Sim, Hong Bo; Kim, Misung

    2016-01-01

    Periosteal chondroma is a very unusual cartilaginous neoplasm of the spinal canal. We herein report a case of periosteal chondroma in a 41-year-old male who presented with gait disturbance and paresthesia of both lower extremities. Magnetic resonance (MR) images showed an extradural mass which caused compression of the spinal cord at the T5/6 level. The mass showed iso-signal intensity on T1-weighted images, high signal intensity on T2-weighted images, and nodular and peripheral rim enhancement on post-contrast T1-weighted images. Computed tomography (CT) images showed a mass with punctate calcifications and extension into the left T5/6 neural foramen. MR and CT images showed extrinsic cortical bone erosion of the posterior inferior body of T5 and superior pedicle of T6, bone remodeling with overhanging margins, and sclerosis adjacent to the tumor. The patient underwent a complete excision of the mass by left T5/6 hemi-laminectomy and exhibited complete resolution of his symptoms. Histopathologic examination revealed periosteal chondroma. Tumor recurrence was not recorded during the 18-month follow-up period. (orig.)

  5. Periostitis and localised myositis in polyarteritis nodosa

    International Nuclear Information System (INIS)

    Macdonald, W.B.G.; Blake, M.P.

    2003-01-01

    Full text: A 20-year-old man with previously diagnosed polyarteritis nodosa was referred for a bone scan to investigate longstanding knee and lower leg pain. The patient's symptoms worsened with any reduction of steroid dose and his physician was concerned about avascular necrosis of the hips. Plain x-rays of the lower limbs were normal. The blood pool images showed bilaterally increased activity in the anterior muscle compartments of the lower legs, suggestive of localised myositis. Three-hour delayed images showed widespread, increased subperiosteal activity with no evidence of avascular necrosis. Subsequent MRI scanning showed patchy muscle enhancement in both lower legs, also typical of myositis. A muscle biopsy was performed which demonstrated features of both myositis and vasculitis. The patient remains dependent on high-dose steroids for symptom relief. Localised myositis has previously been reported in polyarteritis nodosa and is a recognised, albeit rare, complication of the disorder, the basis of which is not well understood. Diagnostic muscle biopsy should be directed at involved muscle groups, which are best detected with MRI. Lower limb periostitis is well described in polyarteritis nodosa and may result in gross deformity. Several cases have previously been reported in the literature based on radiographic abnormalities, which were not present in our patient. Bone scanning demonstrated the sub-periosteal activity well in our subject and is suggested as a useful investigation in patients with polyarteritis nodosa who complain of lower limb pain. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  6. Unilateral mid-femoral periosteal newbone of varying aetiology in children. Radiographic analysis of 25 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kozlowski, K.; Diard, F.; Padovani, J.; Sprague, P.; Pietron, K.

    1986-09-01

    Thigh pain is a serious condition in childhood and should be promptly and thoroughly investigated. Twenty-five cases of thigh pain lasting between 1 day and 7 months with mid-femoral periosteal thickening were analysed. There were 10 patients with Ewing's sarcoma, 7 with eosinophilic granuloma, 1 with osteoid osteoma, 1 with leukaemia, 3 with osteomyelitis, 1 with myositis and 2 with post-traumatic periosteal reaction. It was shown that patients with Ewing's sarcoma and eosinophilic granuloma have certain patterns of X-ray changes in high diagnostic value, which allow a proper diagnosis in most cases.

  7. Calvarial periosteal graft for second-stage cleft palate surgery: a preliminary report.

    Science.gov (United States)

    Neiva, Cecilia; Dakpe, Stephanie; Gbaguidi, Cica; Testelin, Sylvie; Devauchelle, Bernard

    2014-07-01

    The objectives of cleft palate surgery are to achieve optimal outcomes regarding speech development, hearing, maxillary arch development and facial skull growth. Early two-stage cleft palate repair has been the most recent protocol of choice to achieve good maxillary arch growth without compromising speech development. Hard palate closure occurs within one year of soft palate surgery. However, in some cases the residual hard palate cleft width is larger than 15 mm at the age of two. As previously reported, integrated speech development starts around that age and it is a challenge since we know that early mobilization of the mucoperiosteum interferes with normal facial growth on the long-term. In children with large residual hard palate clefts at the age 2, we report the use of calvarial periosteal grafts to close the cleft. With a retrospective 6-year study (2006-2012) we first analyzed the outcomes regarding impermeability of hard palate closure on 45 patients who at the age of two presented a residual cleft of the hard palate larger than 15 mm and benefited from a periosteal graft. We then studied the maxillary growth in these children. In order to compare long-term results, we included 14 patients (age range: 8-20) treated between 1994 & 2006. Two analyses were conducted, the first one on dental casts from birth to the age of 6 and the other one based on lateral cephalograms following Delaire's principles and TRIDIM software. After the systematic cephalometric analysis of 14 patients, we found no evidence of retrognathia or Class 3 dental malocclusion. In the population of 45 children who benefited from calvarial periosteal grafts the rate of palate fistula was 17% vs. 10% in the overall series. Despite major advances in understanding cleft defects, the issues of timing and choice of the surgical procedure remain widely debated. In second-stage surgery for hard palate closure, using a calvarial periosteal graft could be the solution for large residual clefts

  8. Insulin-like growth factor-1 receptor in mature osteoblasts is required for periosteal bone formation induced by reloading

    Science.gov (United States)

    Kubota, Takuo; Elalieh, Hashem Z.; Saless, Neema; Fong, Chak; Wang, Yongmei; Babey, Muriel; Cheng, Zhiqiang; Bikle, Daniel D.

    2013-11-01

    Skeletal loading and unloading has a pronounced impact on bone remodeling, a process also regulated by insulin-like growth factor-1 (IGF-1) signaling. Skeletal unloading leads to resistance to the anabolic effect of IGF-1, while reloading after unloading restores responsiveness to IGF-1. However, a direct study of the importance of IGF-1 signaling in the skeletal response to mechanical loading remains to be tested. In this study, we assessed the skeletal response of osteoblast-specific Igf-1 receptor deficient (Igf-1r-/-) mice to unloading and reloading. The mice were hindlimb unloaded for 14 days and then reloaded for 16 days. Igf-1r-/- mice displayed smaller cortical bone and diminished periosteal and endosteal bone formation at baseline. Periosteal and endosteal bone formation decreased with unloading in Igf-1r+/+ mice. However, the recovery of periosteal bone formation with reloading was completely inhibited in Igf-1r-/- mice, although reloading-induced endosteal bone formation was not hampered. These changes in bone formation resulted in the abolishment of the expected increase in total cross-sectional area with reloading in Igf-1r-/- mice compared to the control mice. These results suggest that the Igf-1r in mature osteoblasts has a critical role in periosteal bone formation in the skeletal response to mechanical loading.

  9. Platelet Lysate: The Better Choice for Jaw Periosteal Cell Mineralization

    Directory of Open Access Journals (Sweden)

    Yvonne Wanner

    2017-01-01

    Full Text Available Previously, we demonstrated a high quality of minerals formed by serum-free cultured jaw periosteal cells (JPCs by Raman spectroscopy but the mineralization extent was not satisfactory. In the present study, we analyzed the proliferation and mineralization potential of human platelet lysate- (hPL- cultured JPCs in comparison to that of FCS-cultured JPCs. By cell impedance measurements, we detected significantly higher population doubling times of PL-cultured JPCs in comparison to FCS-cultured JPCs. However, this result was not based on lower proliferation activities but on diminished cell sizes which JPCs develop under PL cultivation. The measurements of the metabolic activities clearly showed significantly higher cell proliferation rates under PL culturing. Equivalent levels of the mesenchymal cell markers CD29, CD45, CD73, CD90, and CD105 were detected, but there were significantly increased MSCA-1 levels under PL cultivation. While JPCs only occasionally mineralize under FCS culture conditions, the mineralization potential was significantly stronger under PL cultivation. Moreover, in 4 of 5 analyzed patient cells, the addition of dexamethasone was proved no longer necessary for strong mineralization of PL-cultured JPCs. We conclude that in vitro cultivation of JPCs with platelet lysate is a suitable alternative to FCS culture conditions and a powerful tool for the development of high-quality TE constructs using jaw periosteal cells.

  10. Platelet Lysate: The Better Choice for Jaw Periosteal Cell Mineralization.

    Science.gov (United States)

    Wanner, Yvonne; Umrath, Felix; Waidmann, Marc; Reinert, Siegmar; Alexander, Dorothea

    2017-01-01

    Previously, we demonstrated a high quality of minerals formed by serum-free cultured jaw periosteal cells (JPCs) by Raman spectroscopy but the mineralization extent was not satisfactory. In the present study, we analyzed the proliferation and mineralization potential of human platelet lysate- (hPL-) cultured JPCs in comparison to that of FCS-cultured JPCs. By cell impedance measurements, we detected significantly higher population doubling times of PL-cultured JPCs in comparison to FCS-cultured JPCs. However, this result was not based on lower proliferation activities but on diminished cell sizes which JPCs develop under PL cultivation. The measurements of the metabolic activities clearly showed significantly higher cell proliferation rates under PL culturing. Equivalent levels of the mesenchymal cell markers CD29, CD45, CD73, CD90, and CD105 were detected, but there were significantly increased MSCA-1 levels under PL cultivation. While JPCs only occasionally mineralize under FCS culture conditions, the mineralization potential was significantly stronger under PL cultivation. Moreover, in 4 of 5 analyzed patient cells, the addition of dexamethasone was proved no longer necessary for strong mineralization of PL-cultured JPCs. We conclude that in vitro cultivation of JPCs with platelet lysate is a suitable alternative to FCS culture conditions and a powerful tool for the development of high-quality TE constructs using jaw periosteal cells.

  11. Case report 834: Chronic sclerosing osteomyelitis of the mandible with long bone periostitis.

    Science.gov (United States)

    Stewart, A; Carneiro, R; Pollock, L; Shaw, D

    1994-04-01

    We present the case of a patient with primary chronic osteomyelitis of the mandible, the radiological appearance of which is compatible with a diagnosis of chronic sclerosing osteomyelitis. The accompanying femoral and tibial periosteal reactive new bone formation and the benign clinical course suggest that this presentation may represent a form of chronic multifocal osteomyelitis.

  12. Chondrosarcoma of the femur with histology-imaging correlation of tumor growth--preliminary observations concerning periosteal new bone formation and soft tissue extension.

    Science.gov (United States)

    Steiner, German C; Schweitzer, Mark E; Kenan, Samuel; Abdelwahab, Ibrahim F

    2011-01-01

    The objective of this study was, in chondrosarcoma (CHS) of the femur, to evaluate by radiologic-pathologic correlation, the degree of tumor growth, cortical destruction, periosteal reaction, and soft tissue extension present. Eight cases of histologically proven CHS of the femur were studied. All cases were resected, evaluated histologically with coronal slabs, and compared with radiographs and magnetic resonance imaging (MRI) scans. In two resected specimens, the tumors were studied in more detail; along with coronal slabs, axial sections of the remaining anterior and posterior halves of both tumors were taken, and the bone specimens were X-rayed and examined histologically. CHS initially involved the medullary cavity and subsequently destroyed the cortex; first, by endosteal scalloping and, second, by subsequent invasion and destruction of the cortex. During this process, there was periosteal new bone formation (PNBF), with increased cortical thickness, the degree of which often correlated with the degree of cortical destruction. In the areas of cortical thickening of three cases, a "grey line" was seen on MRI that separated the cortex from the periosteal new bone; the line, in reality,is a space between the two structures. The presence of this line suggests that the tumor does not extend beyond the cortex. PNBF occurred in all cases and varied in thickness. It frequently developed independent of direct periosteal tumor involvement. The periosteum of one case contained porotic bone with interposed marrow fat, which was easily misinterpreted as tumor extension on MRI. Expansion and remodeling of the femoral diaphysis in CHS, with widening of the medullary cavity, is usually due to extensive cortical destruction with PNBF. Soft tissue extension was present in five cases and apparently occurred by two different mechanisms: direct tumor destruction of the cortex and periosteum, with extension into the soft tissues; and subtle MRI occult tumor permeation through the

  13. Characteristics and outcome and the omphalocele circumference/abdominal circumference ratio in prenatally diagnosed fetal omphalocele

    NARCIS (Netherlands)

    Kleinrouweler, C. E.; Kuijper, C. F.; van Zalen-Sprock, M. M.; Mathijssen, I. B.; Bilardo, C. M.; Pajkrt, E.

    2011-01-01

    To evaluate the outcome of fetuses with prenatally diagnosed omphalocele and to investigate the predictive value of the omphalocele circumference/abdominal circumference (OC/AC) ratio - a measure for the relative size of the omphalocele. This study includes all fetuses prenatally diagnosed with

  14. Paralytic ectropion treatment with lateral periosteal flap canthoplasty and introduction of the ectropion severity score

    NARCIS (Netherlands)

    Korteweg, Steven F S; Stenekes, Martin W; van Zyl, Fiona E; Werker, Paul M N

    BACKGROUND: Paralytic ectropion patients suffer from impairment of function and appearance of the lower eyelid and are at high risk of developing an exposure keratitis. A canthoplasty procedure can reduce the horizontal eyelid laxity and elevate the lower eyelid. We used a periosteal flap from the

  15. Growth hormone mitigates loss of periosteal bone formation and muscle mass in disuse osteopenic rats.

    Science.gov (United States)

    Grubbe, M-C; Thomsen, J S; Nyengaard, J R; Duruox, M; Brüel, A

    2014-12-01

    Growth hormone (GH) is a potent anabolic agent capable of increasing both bone and muscle mass. The aim was to investigate whether GH could counteract disuse-induced loss of bone and muscle mass in a rat model. Paralysis was induced by injecting 4 IU Botox (BTX) into the muscles of the right hind limb. Sixty female Wistar rats, 14 weeks old, were divided into the following groups: baseline, controls, BTX, BTX+GH, and GH. GH was given at a dosage of 5 mg/kg/d for 4 weeks. Compared with controls, BTX resulted in lower periosteal bone formation rate (BFR/BS,-79%, Pbone mineral density (aBMD, -13%, Pbone volume (BV/TV, -26%, Pbone strength (-12%, Pbone strength was found. In addition, GH partly prevented loss of muscle mass (+29% vs. BTX, P<0.001), and tended to prevent loss of muscle CSA (+11%, P=0.064). In conclusion, GH mitigates disuse-induced loss of periosteal BFR/BS at the mid-femur and rectus femoris muscle mass.

  16. Magnetic resonance imaging findings of periosteal interposition in a distal tibial Salter-Harris type I fracture with surgical correlation: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Nara; Jung, Jee Young; Kang, Ki Ser [Chung-Ang University Hospital, Seoul (Korea, Republic of)

    2013-08-15

    The complication of growth disturbance after physeal fracture of the distal tibia has been well recognized. Although irreducible fractures of the physis due to trapped soft tissue, including periosteum, are not common, it could still cause growth disturbances. Therefore, the detection of periosteal interposition with physeal injury on imaging study is important. We present a case of a 10-year-old girl with surgically confirmed periosteal interposition in the distal tibial Salter-Harris type I fracture, through magnetic resonance imaging findings.

  17. Magnetic resonance imaging findings of periosteal interposition in a distal tibial Salter-Harris type I fracture with surgical correlation: A case report

    International Nuclear Information System (INIS)

    Kim, Nara; Jung, Jee Young; Kang, Ki Ser

    2013-01-01

    The complication of growth disturbance after physeal fracture of the distal tibia has been well recognized. Although irreducible fractures of the physis due to trapped soft tissue, including periosteum, are not common, it could still cause growth disturbances. Therefore, the detection of periosteal interposition with physeal injury on imaging study is important. We present a case of a 10-year-old girl with surgically confirmed periosteal interposition in the distal tibial Salter-Harris type I fracture, through magnetic resonance imaging findings.

  18. ORPLOT.PC: a graphic utility for ORMGEN.PC and ORVIRT.PC

    International Nuclear Information System (INIS)

    Inversini, C.; Bryson, J.W.

    1986-06-01

    ORPLOT.PC is an interactive graphic utility for ORMGEN.PC and ORVIRT.PC. It executes on an IBM PC/XT or PC/AT equipped with hard disk, graphic card, and 512K minimum memory. The program is capable of: (1) displaying finite-element meshes generated by ORMGEN.PC complete with node numbers, element numbers, and boundary conditions; and (2) generating deformed mesh plots, contour plots, line (X-Y) plots, and developed surface plots of ORVIRT.PC output. A zooming feature allows detailed inspection of any subregion. Because simplicity and ease of use were important objectives during program development, all commands are entered interactively using free format. The option of automatic or user-defined scaling for most plots is another convenience. Plot files may be created and written to hard disk for subsequent hardcopy to printer or plotter. 2 refs., 7 figs

  19. Axillary artery injury after an anterior shoulder fracture dislocation and “periosteal sleeve avulsion of the rotator cuff” (SARC. Case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Ash Chehata

    2017-04-01

    Full Text Available We present the rare complication of an axillary artery injury associated with an anterior dislocation of the humerus and what we believe to be the first reported periosteal sleeve avulsion of the entire rotator cuff (SARC. We review the literature and discuss the cause of this unusual injury pattern. Keywords: Axillary artery, Shoulder fracture dislocation, Periosteal sleeve avulsion, SARC

  20. Penile length and circumference: an Indian study.

    Science.gov (United States)

    Promodu, K; Shanmughadas, K V; Bhat, S; Nair, K R

    2007-01-01

    Apprehension about the normal size of penis is a major concern for men. Aim of the present investigation is to estimate the penile length and circumference of Indian males and to compare the results with the data from other countries. Results will help in counseling the patients worried about the penile size and seeking penis enlargement surgery. Penile length in flaccid and stretched conditions and circumference were measured in a group of 301 physically normal men. Erected length and circumference were measured for 93 subjects. Mean flaccid length was found to be 8.21 cm, mean stretched length 10.88 cm and circumference 9.14 cm. Mean erected length was found to be 13.01 cm and erected circumference was 11.46 cm. Penile dimensions are found to be correlated with anthropometric parameters. Insight into the normative data of penile size of Indian males obtained. There are significant differences in the mean penile length and circumference of Indian sample compared to the data reported from other countries. Study need to be continued with a large sample to establish a normative data applicable to the general population.

  1. Characterization of single cell derived cultures of periosteal progenitor cells to ensure the cell quality for clinical application.

    Directory of Open Access Journals (Sweden)

    Stefan Stich

    Full Text Available For clinical applications of cells and tissue engineering products it is of importance to characterize the quality of the used cells in detail. Progenitor cells from the periosteum are already routinely applied in the clinics for the regeneration of the maxillary bone. Periosteal cells have, in addition to their potential to differentiate into bone, the ability to develop into cartilage and fat. However, the question arises whether all cells isolated from periosteal biopsies are able to differentiate into all three tissue types, or whether there are subpopulations. For an efficient and approved application in bone or cartilage regeneration the clarification of this question is of interest. Therefore, 83 different clonal cultures of freshly isolated human periosteal cells derived from mastoid periosteum biopsies of 4 donors were generated and growth rates calculated. Differentiation capacities of 51 clonal cultures towards the osteogenic, the chondrogenic, and the adipogenic lineage were investigated. Histological and immunochemical stainings showed that 100% of the clonal cultures differentiated towards the osteogenic lineage, while 94.1% demonstrated chondrogenesis, and 52.9% could be stimulated to adipogenesis. For osteogenesis real-time polymerase chain reaction (PCR of BGLAP and RUNX2 and for adipogenesis of FABP4 and PPARG confirmed the results. Overall, 49% of the cells exhibited a tripotent potential, 45.1% showed a bipotent potential (without adipogenic differentiation, 3.9% bipotent (without chondrogenic differentiation, and 2% possessed a unipotent osteogenic potential. In FACS analyses, no differences in the marker profile of undifferentiated clonal cultures with bi- and tripotent differentiation capacity were found. Genome-wide microarray analysis revealed 52 differentially expressed genes for clonal subpopulations with or without chondrogenic differentiation capacity, among them DCN, NEDD9, TGFBR3, and TSLP. For clinical

  2. Periosteal Distraction Osteogenesis: An Effective Method for Bone Regeneration

    Directory of Open Access Journals (Sweden)

    Danyang Zhao

    2016-01-01

    Full Text Available The treatment of bone defects is challenging and controversial. As a new technology, periosteal distraction osteogenesis (PDO uses the osteogenicity of periosteum, which creates an artificial space between the bone surface and periosteum to generate new bone by gradually expanding the periosteum with no need for corticotomy. Using the newly formed bone of PDO to treat bone defects is effective, which can not only avoid the occurrence of immune-related complications, but also solve the problem of insufficient donor. This review elucidates the availability of PDO in the aspects of mechanisms, devices, strategies, and measures. Moreover, we also focus on the future prospects of PDO and hope that PDO will be applied to the clinical treatment of bone defects in the future.

  3. Participation of intracellular cysteine proteinases, in particular cathepsin B, in degradation of collagen in periosteal tissue explants

    NARCIS (Netherlands)

    Creemers, L. B.; Hoeben, K. A.; Jansen, D. C.; Buttle, D. J.; Beertsen, W.; Everts, V.

    1998-01-01

    The involvement of cysteine proteinases in the degradation of soft connective tissue collagen was studied in cultured periosteal explants. Using cysteine proteinase inhibitors that were active intracellularly or extracellularly (Ep453 and Ep475, respectively), it was shown that over-all collagen

  4. PC communication

    International Nuclear Information System (INIS)

    Oh, Jae Cheol

    1992-03-01

    This text book is comprised of five charters, which is about PC communication for beginners who need to learn manners and how to use Ketel and PC serve. So it introduces first, conception of PC and precautions on using PC communication, second, preparation for PC communication with Modem, its program, install, kinds of protocol and how to use protocol, third directions of emulator of PC communication and super session, fourth, instruction of Ketel with join and access, basic command of Ketel, list of Ketel's menu, Ketel editor, service guide, directions of News service, Stock and bond service business and economic figures, exchange rate and interest rate, tax culture and leisure, Ketel BBS service and posting. The last part has a instruction of PC-serve about join, basic command of PC-serve, service guide and practical guideline.

  5. PC communication

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jae Cheol

    1992-03-15

    This text book is comprised of five charters, which is about PC communication for beginners who need to learn manners and how to use Ketel and PC serve. So it introduces first, conception of PC and precautions on using PC communication, second, preparation for PC communication with Modem, its program, install, kinds of protocol and how to use protocol, third directions of emulator of PC communication and super session, fourth, instruction of Ketel with join and access, basic command of Ketel, list of Ketel's menu, Ketel editor, service guide, directions of News service, Stock and bond service business and economic figures, exchange rate and interest rate, tax culture and leisure, Ketel BBS service and posting. The last part has a instruction of PC-serve about join, basic command of PC-serve, service guide and practical guideline.

  6. Anatomy and histophysiology of the periosteum: quantification of the periosteal blood supply to the adjacent bone with 85Sr and gamma spectrometry.

    Science.gov (United States)

    Chanavaz, M

    1995-01-01

    The periosteum or periosteal membrane is a continuous composite fibroelastic covering membrane of the bone to which it is intimately linked. Although the bone cortex is the main beneficiary of the principal anatomical and physiological functions of the periosteal membrane, the behavior of the entire bone remains closely influenced by periosteal activity. These principal functions are related to the cortical blood supply, osteogenesis, and muscle and ligament attachments. Through its elastic and contractile nature, it participates in the maintenance of bone shape, and plays an important role in metabolic ionic exchange and physiologic distribution of electro-chemical potential differences across its membranous structure. It has also been suggested that the periosteum may have its own specific proprioceptive property. This paper presents a study of the anatomy and histophysiology of the periosteum, and discusses in detail its main functions of cortical blood supply and osteogenesis. It also presents the third intermediary report on a current study of the quantification of cortical vascularization of femoral bone via the periosteum, using an isotonic salt solution containing 85 Strontium. The afferent-efferent (arterio-venous) flows of this solution in the thigh vascular system of guinea pigs were measured by gamma spectrometry after a series of selective macro- and micro-injections of radioactive salt into the femoral arterial system was carried out. Each vascular territory was meticulously selected and the injections were made according to size, starting with the larger vessels, with or without ligatures of neighboring vessels, going progressively to smaller and smaller vessels with diameters not exceeding 100 microns. The principal technical difficulty at this stage of experimentation was related to the identifying and acquiring of appropriate microcatheters. The study also includes a series of measurements after blockage of the transmuscular blood flow and the

  7. Neck Circumference May Be a Better Alternative to Standard Anthropometric Measures

    Directory of Open Access Journals (Sweden)

    Kaumudi Joshipura

    2016-01-01

    Full Text Available This paper evaluates neck circumference as a metabolic risk marker. Overweight/obese, nondiabetic Hispanics, 40–65 years old, who are free of major cardiovascular diseases, were recruited for the San Juan Overweight Adults Longitudinal Study (SOALS. Baseline exams were completed by 1,206 participants. Partial correlation coefficients (r and logistic models adjusted for age, gender, smoking status, and physical activity were computed. Neck circumference was significantly correlated with waist circumference (r=0.64, BMI (r=0.66, and body fat % (r=0.45. Neck circumference, highest (compared to lowest tertile, had higher association with prediabetes: multivariable OR = 2.30 (95% CI: 1.71–3.06 compared to waist circumference OR = 1.97 (95% CI: 1.48–2.66 and other anthropometric measures. Neck circumference showed higher associations with HOMA, low HDL-C, and triglycerides, multivariable OR = 8.42 (95% CI: 5.43–13.06, 2.41 (95% CI: 1.80–3.21, and 1.52 (95% CI: 1.14–2.03, but weaker associations with hs-CRP and hypertension, OR = 3.61 (95% CI: 2.66–4.90 and OR = 2.58 (95% CI: 1.90–3.49, compared to waist circumference. AIC for model fit was generally similar for neck or waist circumference. Neck circumference showed similar or better associations with metabolic factors and is more practicable than waist circumference. Hence, neck circumference may be a better alternative to waist circumference.

  8. Evaluation of periosteal fixation of lateral rectus and partial VRT for cases of exotropic Duane retraction syndrome

    Directory of Open Access Journals (Sweden)

    Pradeep Sharma

    2014-01-01

    Full Text Available Purpose: The purpose of this study is to evaluate the lateral rectus periosteal fixation and partial vertical rectus transpositioning (VRT as treatment modalities to correct exotropic Duane retraction syndrome (Exo-DRS. Materials and Methods: Prospective interventional case study of cases of Exo-DRS with limitation of adduction. A total of 13 patients were subdivided into two groups. Six patients underwent only lateral rectus periosteal fixation (group A and seven patients also underwent partial VRT (group B. Assessment involved prism bar cover test, abduction and adduction range, extent of binocular single visual field and exophthalmometry. These tests were repeated at 1 week, 1 month and 3 months post-operatively and data analyzed. Results: The pre-operative mean values and ranges were 26.2 Δ (22-35 exotropia for group A and −21.3 Δ (14-30 exotropia for group B. The post-operative mean and range was +0.6 Δ esotropia (+20 to −8 for group A and 8 Δ (−2 to −20 exotropia for group B. Mean grade of limitation of abduction changed from −3.8 to −3.6 versus −3.6 to −2.8 and mean grade of limitation of adduction changed from −1.9 to −0.7 versus −1.5 to −0.5 in the groups A and B respectively. Mean binocular single visual field changed from 14.7° to 23.3° in group A and 11.8° to 26.4° in the group B respectively. Conclusion: Lateral rectus periosteal fixation is an effective surgery to correct the exodeviation, anomalous head posture and improving adduction in Exo-DRS and partial VRT in addition is effective in improving abduction and binocular single visual fields.

  9. [The periosteum: the "umbilical cord" of bone. Quantification of the blood supply of cortical bone of periosteal origin].

    Science.gov (United States)

    Chanavaz, M

    1995-01-01

    The Periosteum or periosteal membrane is a continuous composite fibroelastic covering membrane of the bone to which it is intimately linked. It consists of multipotent mesodermal cells (11, 15). Although the bone cortex is the main beneficiary of the principal anatomical and physiological functions of the periosteal membrane, the behaviour of the entire bone remains closely influenced by the periosteal activity. These principal functions are related to the cortical blood supply, osteogenesis, muscle and ligament attachments. Through its elastic and contractile nature, it participates in the maintenance of bone shape, and plays an important role in metabolic ionic exchange and physiological distribution of electro-chemical potential difference across its membranous structure. It has also been suggested that the periosteum may have its own specific proprioceptive property. This presentation will study the histo-anatomy and physiology of the periosteum and will discuss in detail its main functions of cortical blood supply and osteogenesis (fig. 1 and 2). It will also present the third intermediary report on a current study of the quantification of cortical vascularisation of femoral bone via the periosteum, using an isotonic salt solution of 85Strontium. The afferent-efferent (arterio-venous) flows of this solution in the thigh vascular system of guinea pigs were measured by gamma spectrometry after a series of selective macro and micro injections of radioactive salt into the femoral arterial system were carried out. Each vascular territory was meticulously selected and the injections were made according to size, starting with the larger vessels, with or without ligatures of neighbouring vessels, going progressively to smaller and smaller vessels not exceeding 100m in diameter.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Are age references for waist circumference, hip circumference and waist-hip ratio in Dutch children useful in clinical practice?

    NARCIS (Netherlands)

    Fredriks, A.M.; Buuren, S. van; Fekkes, M.; Verloove-Vanhorick, S.P.; Wit, J.M.

    2005-01-01

    The aim of this study was to present age references for waist circumference (WC), hip circumference (HC), and waist/hip ratio (WHR) in Dutch children. Cross-sectional data were obtained from 14,500 children of Dutch origin in the age range 0-21 years. National references were constructed with the

  11. HEAD CIRCUMFERENCE REFERENCES FOR SCHOOL AGE CHILDREN IN WESTERN ROMANIA.

    Science.gov (United States)

    Chirita-Emandi, Adela; Doros, Gabriela; Simina, Iulia Jurca; Gafencu, Mihai; Puiu, Maria

    2015-01-01

    To provide head circumference references for school-aged children in western Romania, and compare them with references from other European countries. A total of 2742 children, aged 6-19 years, from Timis county, were examined by medical students, between February 2010-June 2011. Head circumference references were constructed by Cole's LMS method with LMSChartMaker software. The Romanian 3rd, 50th and 97th percentiles for head circumference were compared with recent references from Belgium and Germany. Generally, boys show significantly larger head circumference compared to girls at any age. The head circumference increments between 6 and 19 years are Romania to those from Germany and Belgium, we found lower median head circumference in Romanian boys and girls, that could be explained by a taller stature of boys and girls in Germany and Belgium compared to Romania.

  12. Secondary chondrocyte-derived Ihh stimulates proliferation of periosteal cells during chick development.

    Science.gov (United States)

    Buxton, Paul G; Hall, Brian; Archer, Charles W; Francis-West, Philippa

    2003-10-01

    The development of the skull is characterised by its dependence upon epigenetic influences. One of the most important of these is secondary chondrogenesis, which occurs following ossification within certain membrane bone periostea, as a result of biomechanical articulation. We have studied the genesis, character and function of the secondary chondrocytes of the quadratojugal of the chick between embryonic days 11 and 14. Analysis of gene expression revealed that secondary chondrocytes formed coincident with Sox9 upregulation from a precursor population expressing Cbfa1/Runx2: a reversal of the normal sequence. Such secondary chondrocytes rapidly acquired a phenotype that is a compound of prehypertrophic and hypertrophic chondrocytes, exited from the cell cycle and upregulated Ihh. Pulse and pulse/chase experiments with BrdU confirmed the germinal region as the highly proliferative source of the secondary chondrocytes, which formed by division of chondrocyte-committed precursors. By blocking Hh signalling in explant cultures we show that the enhanced proliferation of the germinal region surrounding the secondary chondrocytes derives from this Ihh source. Additionally, in vitro studies on membrane bone periosteal cells (non-germinal region) demonstrated that these cells can also respond to Ihh, and do so both by enhanced proliferation and precocious osteogenesis. Despite the pro-osteogenic effects of Ihh on periosteal cell differentiation, mechanical articulation of the quadratojugal/quadrate joint in explant culture revealed a negative role for articulation in the regulation of osteocalcin by germinal region descendants. Thus, the mechanical stimulus that is the spur to secondary chondrocyte formation appears able to override the osteogenic influence of Ihh on the periosteum, but does not interfere with the cell cycle-promoting component of Hh signalling.

  13. Mid-upper-arm-circumference and mid-upper-arm circumference z-score

    DEFF Research Database (Denmark)

    Rasmussen, J; Andersen, A; Fisker, A B

    2012-01-01

    Mid-upper-arm circumference (MUAC) is a simple method of assessing nutritional status in children above 6 months of age. In 2007 World Health Organization (WHO) introduced a MUAC z-score for children above 3 months of age. We evaluated whether MUAC or MUAC z-score had the best ability to identify...

  14. Tratamiento de la periostitis tibial en corredores: revisión sistemática

    OpenAIRE

    Díaz Idígoras, Anko

    2014-01-01

    RESUMEN: Objetivo: el propósito de este trabajo es realizar una revisión sistemática de la literatura actual sobre las técnicas de tratamiento de la periostitis tibial y valorar así su efectividad y calidad. Material y métodos: Para la elaboración de esta revisión se ha efectuado una búsqueda exhaustiva de las principales bases de datos de ciencias de la salud (PubMed, PEDro, ScienceDirect, Cochrane y LILACS) además de búsquedas manuales y de literatura gris. Los parámetros de búsqueda fueron...

  15. Management of iatrogenically exposed maxillary sinus with a broken periosteal elevator trapped inside

    Directory of Open Access Journals (Sweden)

    Nureldeen Elhammali

    2017-01-01

    Full Text Available Foreign bodies may be ingested after being inserted into an oral cavity or deposited in the body by traumatic or iatrogenic injury. Accidentally left out foreign materials are common complications of dental procedures including apical deposition of endodontic materials, sub-mucosal amalgam pieces, graphite tattoos and traumatically introduced dental materials and instruments. Once a foreign material is left behind within a soft and/or hard tissue, it promotes local inflammation and infection that may cause pain and/or destruction within the surrounding tissues. This article presents a case of retrieval of iatrogenically broken periosteal elevator trapped in the maxillary sinus.

  16. Sonographic large fetal head circumference and risk of cesarean delivery.

    Science.gov (United States)

    Lipschuetz, Michal; Cohen, Sarah M; Israel, Ariel; Baron, Joel; Porat, Shay; Valsky, Dan V; Yagel, Oren; Amsalem, Hagai; Kabiri, Doron; Gilboa, Yinon; Sivan, Eyal; Unger, Ron; Schiff, Eyal; Hershkovitz, Reli; Yagel, Simcha

    2018-03-01

    Persistently high rates of cesarean deliveries are cause for concern for physicians, patients, and health systems. Prelabor assessment might be refined by identifying factors that help predict an individual patient's risk of cesarean delivery. Such factors may contribute to patient safety and satisfaction as well as health system planning and resource allocation. In an earlier study, neonatal head circumference was shown to be more strongly associated with delivery mode and other outcome measures than neonatal birthweight. In the present study we aimed to evaluate the association of sonographically measured fetal head circumference measured within 1 week of delivery with delivery mode. This was a multicenter electronic medical record-based study of birth outcomes of primiparous women with term (37-42 weeks) singleton fetuses presenting for ultrasound with fetal biometry within 1 week of delivery. Fetal head circumference and estimated fetal weight were correlated with maternal background, obstetric, and neonatal outcome parameters. Elective cesarean deliveries were excluded. Multinomial regression analysis provided adjusted odds ratios for instrumental delivery and unplanned cesarean delivery when the fetal head circumference was ≥35 cm or estimated fetal weight ≥3900 g, while controlling for possible confounders. In all, 11,500 cases were collected; 906 elective cesarean deliveries were excluded. A fetal head circumference ≥35 cm increased the risk for unplanned cesarean delivery: 174 fetuses with fetal head circumference ≥35 cm (32%) were delivered by cesarean, vs 1712 (17%) when fetal head circumference cesarean delivery by an adjusted odds ratio of 1.75 (95% confidence interval, 1.4-2.18) controlling for gestational age, fetal gender, and epidural anesthesia. The rate of prolonged second stage of labor was significantly increased when either the fetal head circumference was ≥35 cm or the estimated fetal weight ≥3900 g, from 22.7% in the total

  17. Concerted actions of insulin-like growth factor 1, testosterone, and estradiol on peripubertal bone growth: a 7-year longitudinal study.

    Science.gov (United States)

    Xu, Leiting; Wang, Qin; Wang, Qingju; Lyytikäinen, Arja; Mikkola, Tuija; Völgyi, Eszter; Cheng, Shumei; Wiklund, Petri; Munukka, Eveliina; Nicholson, Patrick; Alén, Markku; Cheng, Sulin

    2011-09-01

    A better understanding of how bone growth is regulated during peripuberty is important for optimizing the attainment of peak bone mass and for the prevention of osteoporosis in later life. In this report we used hierarchical models to evaluate the associations of insulin-like growth factor 1 (IGF-1), estradiol (E(2) ), and testosterone (T) with peripubertal bone growth in a 7-year longitudinal study. Two-hundred and fifty-eight healthy girls were assessed at baseline (mean age 11.2 years) and at 1, 2, 3.5, and 7 years. Serum concentrations of IGF-1, E(2) , and T were determined. Musculoskeletal properties in the left lower leg were measured using peripheral quantitative computed tomography (pQCT). Serum levels of IGF-1, E(2) , and T increased dramatically before menarche, whereas they decreased, plateaued, or increased at a lower rate, respectively, after menarche. IGF-1 level was positively associated with periosteal circumference (PC) and total bone mineral content (tBMC) throughout peripuberty but not after adjustment for muscle cross-sectional area (mCSA). On the other hand, IGF-1 was associated with tibial length (TL) independently of mCSA before menarche. T was positively associated with TL, PC, tBMC, and cortical volumetric bone mineral density, independent of mCSA, before menarche but not after. E(2) was associated with TL positively before menarche but negatively after menarche. These findings suggest that during puberty, circulating IGF-1 promotes bone periosteal apposition and mass accrual indirectly, probably through stimulating muscle growth, whereas the effects of sex steroids on bone growth differ before and after menarche, presenting a biphasic pattern. Hence the concerted actions of these hormones are essential for optimal bone development in peripuberty. Copyright © 2011 American Society for Bone and Mineral Research.

  18. Large Parosteal Lipoma without Periosteal Changes

    Directory of Open Access Journals (Sweden)

    Shimpo Aoki, MD, PhD

    2015-01-01

    Full Text Available Summary: Parosteal lipoma is a rare tumor, accounting for approximately 0.3% of all lipomas. Bony lesions are often found in patients with this tumor (59.2%, making the differential diagnosis of malignant tumors important. Our case was a 64-year-old male patient who complained of a 25 × 15-cm mass on his right thigh that had grown rapidly over a 2-month period. On magnetic resonance imaging, a high-intensity lesion was observed on the surface of the femur beneath the vastus medialis muscle on T1 and T2 images, with low intensity on a T1 fat suppression image. No significant bony changes were detected. During total tumor resection, the tumor was found on the femur with tight continuity, with tiny areas of spiculation palpable on the bone surface. The exact tumor size was 18 × 13 × 6 cm. The pathological diagnosis was lipoma, the same result as in the former open biopsy. This case was the largest parosteal lipoma of the femur reported without periosteal changes. In cases of deep parosteal lipomas, the detection of rapidly progressive and growing pseudotumors with ossification or chondromatous changes implies malignancy. A preoperative biopsy is mandatory and must be followed by careful planning and preparation for handling in malignant cases. Plastic surgeons should therefore keep the diagnosis of parosteal lipoma in mind to provide appropriate (not too much or too little surgical treatment.

  19. Orgasm and women's waist circumference.

    Science.gov (United States)

    Costa, Rui Miguel; Brody, Stuart

    2014-11-01

    Given that adiposity is related to poorer female sexual function, among many other health problems, the present study aimed at testing the hypothesis that larger waist circumference, an index of subcutaneous and abdominal fat mass, is associated with lack of specifically vaginal orgasm. Study design One hundred and twenty Portuguese women of reproductive age had their waist measured and reported their past month frequency of penile-vaginal intercourse (PVI), vaginal orgasm, orgasm from clitoral masturbation during PVI, non-coital partnered sex (in the absence of same-day PVI), non-coital partnered sex orgasm (regardless of same-day PVI), masturbation, and masturbation orgasm. In both simple and partial correlations (controlling for age, social desirability responding, relationship status, and cohabitation status), larger waist circumference was associated with lack of any vaginal orgasm and with having masturbated in the past month. In a multiple regression, larger waist circumference was independently predicted by lesser frequency of vaginal orgasm, greater frequency of masturbation, and older age. Abdominal fat mass appears to be adversely associated with lesser capacity for vaginal orgasm, but not for orgasms from other sexual activities. Results are discussed in the context of vaginal orgasm being relatively more contingent on situations of increased fitness in both partners. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Is neck circumference measurement an indicator for abdominal ...

    African Journals Online (AJOL)

    Background: Neck circumference (NC) measurement is one of the simple screening measurements which can be used as an index of upper body fat distribution to identify obesity. Objectives: The aim of this study was to determine the relationship between neck circumferences and obesity. Methods:A total 411 volunteer ...

  1. Hyperinsulinemia and waist circumference in childhood metabolic syndrome

    International Nuclear Information System (INIS)

    Lone, S.W.; Ibrahim, M.N.; Leghari, T.M.; Khan, Y.N.; Raza, J.

    2011-01-01

    To determine the characteristics of obese children presenting at a tertiary care hospital and the frequency of metabolic syndrome (MS) in them using two paediatric definitions. A total of 262 obese children aged 4-16 years, with BMI greater than 95 percentile were included. Children having obesity due to syndromes, medications causing weight gain, chronic illness and developmental disability were excluded. Blood pressure, waist circumference, fasting triglycerides, HDL, insulin and glucose levels were obtained. Obesity was defined as BMI > 95 percentile for age and gender according to the UK growth reference charts. The prevalence of metabolic syndrome was estimated using to the De Ferrantis and Lambert definitions. The frequency of MS varied between 16% and 52% depending on whether insulin levels were included in the definition. There was a significant positive correlation(r) when the metabolic parameters were correlated with waist circumference and insulin levels, except HDL which was negatively correlated. All the metabolic parameters like waist circumference, triglycerides, high density lipoprotein cholesterol and systolic blood pressure increased considerably across the insulin quartile (p < 0.05). The most noteworthy anthropometric and metabolic abnormality were the waist circumference (46.5%) and insulin levels (58%) respectively. There was a marked difference in the frequency of metabolic syndrome according to the definition used. The waist circumference and hyperinsulinemia are significant correlates of MS in obese children. There is a need for establishing normal insulin ranges according to age, gender and pubertal status. The clinical examination and investigations ought to include waist circumference and insulin levels together as a part of the definition of MS, for early detection and intervention of childhood obesity. (author)

  2. 76 FR 5467 - Airworthiness Directives; Pilatus Aircraft Ltd. Models PC-6, PC-6-H1, PC-6-H2, PC-6/350, PC-6/350...

    Science.gov (United States)

    2011-02-01

    ...;Prices of new books are listed in the first FEDERAL REGISTER issue of each #0;week. #0; #0; #0; #0;#0..., Fairchild Heli Porter PC-6 airplanes, or Fairchild-Hiller Corporation PC-6 airplanes. Discussion Section... [[Page 5469

  3. Thigh circumference and risk of heart disease and premature death

    DEFF Research Database (Denmark)

    Heitmann, Berit L; Frederiksen, Peder

    2009-01-01

    of follow-up for total death. RESULTS: A small thigh circumference was associated with an increased risk of cardiovascular and coronary heart diseases and total mortality in both men and women. A threshold effect for thigh circumference was evident, with greatly increased risk of premature death below...... circumference seems to be associated with an increased risk of developing heart disease or premature death. The adverse effects of small thighs might be related to too little muscle mass in the region. The measure of thigh circumference might be a relevant anthropometric measure to help general practitioners...... in early identification of individuals at an increased risk of premature morbidity and mortality....

  4. Aspectos radiográficos de periostite ossificante em metatarso de vaca Holandesa Radiografic aspects of ossifying periostitis in metatarsus of Holstein cow

    Directory of Open Access Journals (Sweden)

    Rodrigo Melo Meneses

    2010-05-01

    Full Text Available Periostite ossificante é uma neoformação óssea inflamatória extensa, frequentemente oriunda de infecção de tecidos moles adjacentes ao osso afetado, sendo mais proeminente nos bovinos, especialmente em animais jovens. Neste trabalho, é descrito um caso de periostite ossificante no osso metatársico III direito de uma vaca Holandesa após trauma. O diagnóstico foi realizado com base nos achados clínicos e radiográficos e confirmado cirurgicamente.Ossifying periostitis is an extensive inflamatory new bone formation frequently extensive from soft tissue infection next to these bones. It is more observed in young bovines. A case of pos traumatic ossifying periostitis in the right metatarsus of a Holstein cow is described. The diagnosis was made based on clinical and radiographic findings and confirmed cirurgically.

  5. Dietary predictors of 5-year changes in waist circumference

    DEFF Research Database (Denmark)

    Halkjaer, Jytte; Tjønneland, Anne; Overvad, Kim

    2009-01-01

    the association between intake from 21 food and beverage groups and the subsequent 5-year difference in waist circumference. METHODS: The study population consisted of 22,570 women and 20,126 men, aged 50 to 64 years at baseline, with complete data on baseline and follow-up waist circumference, baseline diet (192...... items food frequency questionnaire), body mass index, and selected potential confounders (eg, smoking status, sport activities, and intake of alcoholic beverages). Multiple linear regression analyses were performed. RESULTS: For women, 5-year difference in waist circumference was inversely related...... intake was positively associated. Sex differences occurred for vegetables, high-fat dairy products, and processed meat. CONCLUSIONS: The results suggest that a diet low in fruits and red meat and high in snack foods was associated with larger waist circumference gains in both sexes. Furthermore, in women...

  6. The value of hip circumference/heightx ratio for identifying childhood hypertension

    OpenAIRE

    Lu, Na; Wang, Rui; Ji, Meijing; Liu, Xiaoli; Qiang, Lu; Ma, Chunming; Yin, Fuzai

    2018-01-01

    To investigate the value of hip circumference related indexes for identifying childhood hypertension. In 2011, 1,352 Han children aged 7–12 years were recruited in our study. Hypertension was defined as systolic blood pressure or diastolic blood pressure ≥95th percentile for all three screenings. We set the power value of the hip circumference/heightx ratio (x = 0, 0.8, 1 and 1.5) and studied the association with blood pressure. Hip circumference, hip circumference/height0.8, hip circumferenc...

  7. Evaluation of Internet-Based Interventions on Waist Circumference Reduction: A Meta-Analysis.

    Science.gov (United States)

    Seo, Dong-Chul; Niu, Jingjing

    2015-07-21

    Internet-based interventions are more cost-effective than conventional interventions and can provide immediate, easy-to-access, and individually tailored support for behavior change. Waist circumference is a strong predictor of an increased risk for a host of diseases, such as hypertension, diabetes, and dyslipidemia, independent of body mass index. To date, no study has examined the effect of Internet-based lifestyle interventions on waist circumference change. This study aimed to systematically review the effect of Internet-based interventions on waist circumference change among adults. This meta-analysis reviewed randomized controlled trials (N=31 trials and 8442 participants) that used the Internet as a main intervention approach and reported changes in waist circumference. Internet-based interventions showed a significant reduction in waist circumference (mean change -2.99 cm, 95% CI -3.68 to -2.30, I(2)=93.3%) and significantly better effects on waist circumference loss (mean loss 2.38 cm, 95% CI 1.61-3.25, I(2)=97.2%) than minimal interventions such as information-only groups. Meta-regression results showed that baseline waist circumference, gender, and the presence of social support in the intervention were significantly associated with waist circumference reduction. Internet-based interventions have a significant and promising effect on waist circumference change. Incorporating social support into an Internet-based intervention appears to be useful in reducing waist circumference. Considerable heterogeneity exists among the effects of Internet-based interventions. The design of an intervention may have a significant impact on the effectiveness of the intervention.

  8. Growth hormone mitigates loss of periosteal bone formation and muscle mass in disuse osteopenic rats

    DEFF Research Database (Denmark)

    Grubbe, M-C; Thomsen, Jesper Skovhus; Nyengaard, J R

    2014-01-01

    Growth hormone (GH) is a potent anabolic agent capable of increasing both bone and muscle mass. The aim was to investigate whether GH could counteract disuse-induced loss of bone and muscle mass in a rat model. Paralysis was induced by injecting 4 IU Botox (BTX) into the muscles of the right hind...... of periosteal BFR/BS (2-fold increase vs. BTX, Pmuscle mass (+29% vs. BTX, Pmuscle CSA (+11%, P=0.064). In conclusion, GH mitigates disuse......BMD, -13%, Pmuscle mass (-69%, Pmuscle cell cross sectional area (CSA) (-73%, P

  9. Massive periosteal reaction a presenting feature of acute megakaryocytic leukemia.

    Science.gov (United States)

    Ueda, Takahiro; Ito, Yasuhiko; Maeda, Miho; Fukunaga, Yoshitaka

    2007-12-01

    Acute megakaryoblastic leukemia (AML M7) is a biologically heterogeneous form of acute myeloid leukemia accounting for 14.6% of cases. In many instances in the past, AML M7 has been classified as undifferentiated leukemia, myelodysplasia, myelofibrosis or some other disease because of its complex clinical presentation or the difficulty of obtaining and interpreting bone marrow samples. However, with currently available morphological, cytochemical, cytogenetic and immunophenotypic methods, AML M7 can now be reliably diagnosed. Although the radiographic spectrum of bony changes in leukemia have been well characterized, skeletal X-ray abnormalities in the setting of AML M7 in pediatric patients have been described in few reports that were associated with bone marrow fibrosis. Here we report on a 14-month-old girl who presented with a massive periosteal reaction of the extremities and clavicles associated with myelofibrosis, a presenting feature of AML M7. The bone changes were very unusual in this case.

  10. Glycosaminoglycan composition of PC12 pheochromocytoma cells: a comparison with PC12D cells, a new subline of PC12 cells

    Energy Technology Data Exchange (ETDEWEB)

    Katoh-Semba, R.; Oohira, A.; Sano, M.; Watanabe, K.; Kitajima, S.; Kashiwamata, S.

    1989-03-01

    PC12D cells, a new subline of conventional PC12 cells, respond not only to nerve growth factor but also to cyclic AMP by extending their neurites. These cells are flat in shape and are similar in appearance to PC12 cells that have been treated with nerve growth factor for a few days. In both cell lines, we have characterized the glycosaminoglycans, the polysaccharide moieties of proteoglycans, which are believed to play an important role in cell adhesion and in cell morphology. Under the present culture conditions, only chondroitin sulfate was detected in the media from PC12 and PC12D cells, whereas both chondroitin sulfate and heparan sulfate were found in the cell layers. The levels of cell-associated heparan sulfate and chondroitin sulfate were about twofold and fourfold higher in PC12D cells than in PC12 cells, respectively. Compared to PC12 cells, the amounts of (/sup 35/S)sulfate incorporated for 48 h into chondroitin sulfate were twofold lower but those into heparan sulfate were 35% higher in PC12D cells. The amount of chondroitin sulfate released by PC12D cells into the medium was about a half of that released by PC12 cells. The ratio of (/sup 35/S)sulfate-labeled heparan sulfate to chondroitin sulfate was 6.2 in PC12D cells and 2.2 in PC12 cells. These results suggest that there may be some correlation between the increase in content of glycosaminoglycans and the change in cell morphology, which is followed by neurite outgrowth.

  11. Titanium and polyether ether ketone (PEEK) patient-specific sub-periosteal implants: two novel approaches for rehabilitation of the severely atrophic anterior maxillary ridge.

    Science.gov (United States)

    Mounir, M; Atef, M; Abou-Elfetouh, A; Hakam, M M

    2018-05-01

    The aim of this study was to assess two new protocols for single-stage rehabilitation of the severely atrophic maxillary ridge using customized porous titanium or polyether ether ketone (PEEK) sub-periosteal implants. Ten patients with a severely atrophic anterior maxillary alveolar ridge were divided randomly into two groups (five patients in each) to receive customized sub-periosteal implants fabricated via CAD/CAM technology: group 1, porous titanium implants; group 2, PEEK implants. Prosthetic loading with fixed acrylic bridges was performed 1 month postoperative. The implants were followed-up for 12 months and evaluated for the presence of any sign of radiographic bone resorption, mobility, infection, prosthetic fracture, or implant exposure. The immediate postoperative period was uneventful except for one case complicated by wound dehiscence in group 1. At 12 months, all implants were functionally stable and the patients were comfortable with the prostheses. No signs of radiographic bone resorption, mobility, infection, or prosthetic fracture were observed. Within the limitations of this study, the application of customized porous titanium and PEEK sub-periosteal implants produced through CAD/CAM technology appears to be an acceptable method for single-stage prosthetic rehabilitation of the severely atrophic edentulous anterior maxilla. This study was awarded the best case study at the academy of osseintegration annual meeting 2017, Orlando, Florida. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. VIDEO-PC, SVGA Routines for FORTRAN on PC

    International Nuclear Information System (INIS)

    1994-01-01

    1 - Description of program or function: These primitives are the lowest level routines needed to perform super VGA graphics on a PC. A sample main program is included that exercises the primitives. Both Lahey and Microsoft FORTRAN's have graphics libraries. However, the libraries do not support 256 color graphics at resolutions greater than 320x200. The primitives bypass these libraries while still conforming to standard usage of BIOS. The supported graphics modes depend upon the PC graphics card and its memory. Super VGA resolutions of 640x480 and 800x600 have been tested on an ATI VGA Wonder card with 512 K memory and on several 80486 PC's (unknown manufacturers) at retail stores. 2 - Method of solution: Both Lahey and Microsoft primitives depend upon sending the correct parameters to the PC BIOS (basic input output system) as discussed in the references. 3 - Restrictions on the complexity of the problem: The primitives were developed for 256 color VGA applications. It is known, for instance, that some CGA and 16 color VGA video modes will not operate correctly using these primitives. Potential users should try the test program on their PC/video card combination to determine applicability

  13. Biomimicry 1: PC.

    Science.gov (United States)

    Cumberland, D C; Gunn, J; Malik, N; Holt, C M

    1998-01-01

    The surface properties of stents can be modified by coating them, for example with a polymer. Phosphorylcoline (PC) is the major component of the outer layer of the cell membrane. The haemo- and biocompatibility of a PC-containing polymer is thus based on biomimicry, and has been confirmed by several experiments showing much reduced thrombogenicity of PC-coated surfaces, and porcine coronary artery implants showing no sign of adverse effect. Clinical experience with the PC-coated BiodivYsio appears favourable. The PC coating can be tailored for take up and controlled elution of various drugs for stent-based local delivery, a property which is being actively explored.

  14. Change in neck circumference after shoulder arthroscopy: An observational study

    Directory of Open Access Journals (Sweden)

    Shrividya Chellam

    2015-01-01

    Full Text Available Background and Aims: Shoulder arthroscopy requires fluid irrigation, which causes soft-tissue oedema around chest, neck, and arm intraoperatively, leading to postoperative airway complications. We decided to study the incidence of increase in the neck circumference in shoulder arthroscopy and its effects on the airway. Methods: We studied 32 cases of shoulder arthroscopies over a period of 1-year, performed under general anaesthesia with interscalene block. The neck circumference of patients before and after the procedure was measured along with other parameters. The endotracheal tube cuff was deflated at the end of surgery to determine air leak around the tube. The negative leak test suggested airway oedema. Results: Thirty out of 32 patients showed positive air leak test. The average change in neck circumference was 1.17 ± 1.16 cm and all could be extubated uneventfully. Two showed negative leak test with an increase in neck circumference by 4.5 and 6.4 cm and were not extubated. Multiple regression analysis for risk factors showed intraoperative hypertension as a single predictor for an increase in neck circumference. Conclusion: Change in the neck circumference beyond 4 cm may suggest airway compromise and below 4 cm, airway compromise is unlikely even in the presence of extensive soft-tissue oedema around the shoulder, upper arm and chest.

  15. Raman Spectroscopic Analyses of Jaw Periosteal Cell Mineralization

    Directory of Open Access Journals (Sweden)

    Eva Brauchle

    2017-01-01

    Full Text Available To achieve safer patient treatments, serum-free cell culture conditions have to be established for cell therapies. In previous studies, we demonstrated that serum-free culture favored the proliferation of MSCA-1+ osteoprogenitors derived from the jaw periosteum. In this study, the in vitro formation of bone-specific matrix by MSCA-1+ jaw periosteal cells (JPCs, 3 donors was assessed and compared under serum-free and serum-containing media conditions using the marker-free Raman spectroscopy. Based on a standard fluorescence assay, JPCs from one patient were not able to mineralize under serum-containing culture conditions, whereas the other cells showed similar mineralization levels under both conditions. Raman spectra from mineralizing MSCA-1+ JPCs revealed higher levels of hydroxyapatite formation and higher mineral to matrix ratios under serum-free culture conditions. Higher carbonate to phosphate ratios and higher crystallinity in JPCs cultured under serum-containing conditions indicated immature bone formation. Due to reduced collagen production under serum-free conditions, we obtained significant differences in collagen maturity and proline to hydroxyproline ratios compared to serum-free conditions. We conclude that Raman spectroscopy is a useful tool for the assessment and noninvasive monitoring of in vitro mineralization of osteoprogenitor cells. Further studies should extend this knowledge and improve JPC mineralization by optimizing culture conditions.

  16. Thigh circumference and risk of heart disease and premature death

    DEFF Research Database (Denmark)

    Heitmann, Berit L; Frederiksen, Peder

    2009-01-01

    OBJECTIVE: To examine associations between thigh circumference and incident cardiovascular disease and coronary heart disease and total mortality. DESIGN: Prospective observational cohort study with Cox proportional hazards model and restricted cubic splines. SETTING: Random subset of adults...... in Denmark. PARTICIPANTS: 1436 men and 1380 women participating in the Danish MONICA project, examined in 1987-8 for height, weight, and thigh, hip, and waist circumference, and body composition by impedance. MAIN OUTCOME MEASURES: 10 year incidence of cardiovascular and coronary heart disease and 12.5 years...... of follow-up for total death. RESULTS: A small thigh circumference was associated with an increased risk of cardiovascular and coronary heart diseases and total mortality in both men and women. A threshold effect for thigh circumference was evident, with greatly increased risk of premature death below...

  17. Arm circumference: its importance for dialysis patients in the obesity era.

    Science.gov (United States)

    Akpolat, Tekin; Kaya, Coşkun; Utaş, Cengiz; Arinsoy, Turgay; Taşkapan, Hülya; Erdem, Emre; Yilmaz, M Emin; Ataman, Rezzan; Bozfakioğlu, Semra; Özener, Çetin; Karayaylali, Ibrahim; Kazancioğlu, Rümeyza; Çamsari, Taner; Yavuz, Mahmut; Ersoy, Fevzi; Duman, Soner; Ateş, Kenan

    2013-08-01

    The purposes of this study were to investigate the association between arm circumference and body mass index (BMI) and to discuss problems, mainly arm circumference and cuff size mismatch, that could affect the reliability of home blood pressure monitoring (HBPM) among peritoneal dialysis (PD) and hemodialysis (HD) patients. 525 PD and 502 HD patients from 16 centers were included in the study. A two-part questionnaire was used to gather information from the participants. Arm circumferences were categorized into four groups according to the British Hypertension Society cuff size recommendations. Mean BMI and arm circumference of all participants were 25.0 kg/m(2) and 27.6 cm, respectively. There was a significant correlation between BMI and arm circumference. The mean BMI and arm circumference values were higher in PD patients than in HD patients. Requirement of a large-sized adult cuff was more common among PD patients compared to HD patients (14 % vs 8 %, p = 0.002). Since HBPM is a useful tool for clinicians to improve BP control, nephrologists should be aware of the problems related to HBPM in dialysis patients and take an active role to increase the reliability of HBPM.

  18. Stressful life events in pregnancy and head circumference at birth

    DEFF Research Database (Denmark)

    Obel, Carsten; Hedegaard, Morten; Henriksen, Tine Brink

    2003-01-01

    A strong association between stress in pregnancy and small head circumference in infants at birth was reported in 1994. This important finding has never been replicated. In a follow-up study of 4211 participants with singleton pregnancies, information on life events was collected twice during...... pregnancy and head circumference measured shortly after birth following standard procedures. No association was found between experienced or perceived stress as a result of life events during pregnancy and head circumference in the infants. In conclusion, stress in pregnancy may influence foetal brain...

  19. Accuracy of self-reported height, weight and waist circumference in a Japanese sample.

    Science.gov (United States)

    Okamoto, N; Hosono, A; Shibata, K; Tsujimura, S; Oka, K; Fujita, H; Kamiya, M; Kondo, F; Wakabayashi, R; Yamada, T; Suzuki, S

    2017-12-01

    Inconsistent results have been found in prior studies investigating the accuracy of self-reported waist circumference, and no study has investigated the validity of self-reported waist circumference among Japanese individuals. This study used the diagnostic standard of metabolic syndrome to assess the accuracy of individual's self-reported height, weight and waist circumference in a Japanese sample. Study participants included 7,443 Japanese men and women aged 35-79 years. They participated in a cohort study's baseline survey between 2007 and 2011. Participants' height, weight and waist circumference were measured, and their body mass index was calculated. Self-reported values were collected through a questionnaire before the examination. Strong correlations between measured and self-reported values for height, weight and body mass index were detected. The correlation was lowest for waist circumference (men, 0.87; women, 0.73). Men significantly overestimated their waist circumference (mean difference, 0.8 cm), whereas women significantly underestimated theirs (mean difference, 5.1 cm). The sensitivity of self-reported waist circumference using the cut-off value of metabolic syndrome was 0.83 for men and 0.57 for women. Due to systematic and random errors, the accuracy of self-reported waist circumference was low. Therefore, waist circumference should be measured without relying on self-reported values, particularly in the case of women.

  20. Learning circumference concepts from the didactical situations theory perspective

    Directory of Open Access Journals (Sweden)

    Valdir de Sousa Cavalcanti

    2013-08-01

    Full Text Available The circumference study, as its importance, it is one of the most relevant contents in the Analytical Geometry curriculum. However, the complexity of related concepts to this theme linked to the content fragmentation, it difficulties the students thinking of transforming geometrical problems into equations solution, systems or inequations. Within, in this article we present a partial report of a master research work, of qualitative mode, which aimed to develop and to evaluate an alternative methodology by using musical parody composition to the teaching of Mathematics in trying to contribute to the circumference concepts learning process. For that, we carried out a case study with 36 third year high school students of a public school from the city of Campina Grande, Paraíba. The research work was based and discussed on Brousseau Didactical Situation Theory. It was chosen triangulation technique for the data analyses, collected from interviews, questionnaires and a list of mathematical exercises. We concluded that the parody composition resource allowed the students better understand the concepts of center, ratio, cord and the definition of the general circumference equation, as they were capable to identify the relative positions which a circumference assumes in relation to an equation of a straight line and between two circumferences in the various concepts that differentiated them. Thus, we can state that the musical parody composition as a didactical resource can contribute to the learning of mathematical contents.

  1. Relationship between neck circumference, insulin resistance and arterial stiffness in overweight and obese subjects.

    Science.gov (United States)

    Fantin, Francesco; Comellato, Gabriele; Rossi, Andrea P; Grison, Elisa; Zoico, Elena; Mazzali, Gloria; Zamboni, Mauro

    2017-09-01

    Background Only a few studies have investigated the relationship between neck circumference and cardiometabolic risk. The aim of this study was to assess the relationships between neck circumference, waist circumference, metabolic variables and arterial stiffness in a group of overweight and obese subjects evaluating a possible independent role of neck circumference in determining arterial stiffness. Methods and results We studied 95 subjects (53 women) with an age range of 20-77 years and body mass index range from 25.69 to 47.04 kg/m 2 . In each subject we evaluated body mass index, waist, hip and neck circumference, systolic and diastolic blood pressure, insulin, fasting glucose, cholesterol, low-density lipoprotein and high-density lipoprotein cholesterol and triglycerides. Arterial stiffness was assessed by carotid-femoral pulse wave velocity (PWVcf) and carotid-radial pulse wave velocity (PWVcr). Both PWVcf and PWVcr were higher in subjects with high values of neck circumference compared with subjects with normal values of neck circumference. Subjects with high values of neck circumference and abdominal obesity presented higher values of mean arterial pressure, PWVcr and homeostasis model assessment (HOMA) index and lower values of high-density lipoprotein than subjects with only abdominal obesity. Two models of stepwise multiple regression were performed in order to evaluate the combined effect of independent variables on arterial stiffness. In the first model PWVcf was considered a dependent variable, and age, gender, systolic blood pressure, triglycerides, high-density lipoprotein cholesterol, waist circumference, neck circumference, HOMA index and the use of anti-hypertensive medications were considered independent variables. Age, systolic blood pressure, triglycerides and waist circumference were significant predictors of PWVcf, explaining 65% of its variance. In the second model, in which PWVcr was considered a dependent variable, neck circumference

  2. Waist circumference as an indicator of high blood pressure in preschool obese children.

    Science.gov (United States)

    Chen, Bin; Li, Hai-fei

    2011-01-01

    To investigate the relationship between waist circumference and blood pressure (BP) to determine if waist circumference was an indicator of BP in preschool children. Body weight, height, waist circumference (WC), hip circumference, and blood pressure of 939 3-6-year-old preschool children were collected. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) in obese children were significantly higher than that in normal weight children in both sexes (phigh blood pressure in children of both sexes. Multiple linear stepwise regression analysis using SBP as the dependent variable showed that BMI and WC were significant independent factors that influence high blood pressure adjusted for age, WtHr and waist-to-hip circumference ratio (WHr) in boys. When using DBP as the dependent variable, BMI was the only significant independent factor that influenced high blood pressure adjusted for age, WtHr and WHr, in both sex-es. Waist circumference was independently associated with high blood pressure in boys aged 3-6 years. In addition to BMI, increased waist circumference was found to be an indicator of high blood pressure in the preschool children, especially in boys.

  3. CALF CIRCUMFERENCE AT BIRTH: A SCREENING METHOD FOR DETECTION OF LOW BIRTH WEIGHT

    Directory of Open Access Journals (Sweden)

    Sandip Kumar

    2012-12-01

    Full Text Available Background: Low Birth Weight (LBW babies run a higher risk of morbidity and mortality in the perinatal period. However, in our country where almost 70-80% births take place at home and peripheral hospitals, taking accurate weight is a problem due to unavailability of weighing scale and trained personnel. Hence there is a constant search for newer methods to detect LBW babies so that early interventions can be instituted. Various authors have used different surrogate anthropometric measurements from different parts of our country. In the present study, an attempt was made to validate the feasibility of using calf circumference as a predictor of LBW babies that can be used by a trained or untrained person. Objectives: To study various anthropometric measurements including calf circumference in newborns and to correlate various measurements with birth weight. Methods: The present study was conducted in the department of Social & Preventive Medicine, MLB Medical College, Jhansi (UP for a period of one year. The study included 1100 consecutively delivered neonates in the maternity ward of MLB Medical College Hospital, Jhansi (UP. The birth weight (Wt, crown heel length (CHL, crown rump length (CRL, head circumference (HC, chest circumference (CC, mid arm circumference (MAC, thigh circumference (TC and calf circumference (CC by standard techniques. All the measurements were taken by a single person throughout the study period with in 24 hours of delivery. Standard statistical methods were adopted for determination of critical limit, sensitivity, specificity and correlation coefficient of different anthropometric measurements in relation to birth weight. Results: Analysis of data indicates that out of 1100 newborns, 55.64% were low birth weight. The percentage of newborns > 2500gm was 44.36. Overall average birth weight was 2348 ± 505gm. Out of 1100 newborns, 608 (55.27% were males and 492 (44.73% were females. Average birth weight for males was 2412

  4. Developing learning trajectory on the circumference of a cycle with realistic mathematics education (RME)

    Science.gov (United States)

    Indriani, Novi; Julie, Hongki

    2017-08-01

    According Nuranisa, the students' difficulties on a lesson about the circumference of a circle were to understand the concept of what was the circumference of a circle and solve problems associated with the circumference of a circle [8]. According Nuranisa, this is because the teacher only gives a formula to find the circumference of a circle without helping students to construct the formula [8]. The purposes of this study were (1) to develop the hypothetical learning trajectory (HLT) for the cycle circumference material, (2) to describe the student results from the HLT implementation. The type of research used in this research was the design research developed by Gravemeijer and Cobb (2006). According Gravemeijer and Cobb, the design research was divided into three stages: (1) preparing for the experiment, (2) design experiments, and (3) retrospective analysis [6]. In this study, researchers developed the student learning trajectories which were help students to construct their knowledge about the understanding and how to calculate the circumference of a circle. The context used on the students' learning trajectory was sports and arts event. The learning trajectory has been tried out for 15 grade five students on the Budya Wacana elementary school in Yogyakarta. In this paper, researchers would describe how the learning trajectory traversed students to construct their knowledge about the understanding and how to calculate the circumference of the circle and the student thinking process on the understanding and how to calculate the circumference of a circle. The results showed that students could construct about the understanding of the circumference of a circle and how to calculate the circumference of a circle through the student learning trajectory.

  5. Neck circumference as a potential marker of metabolic syndrome among college students

    OpenAIRE

    Pereira, Dayse Christina Rodrigues; Araújo, Márcio Flávio Moura de; Freitas, Roberto Wagner Júnior Freire de; Teixeira, Carla Regina de Souza; Zanetti, Maria Lúcia; Damasceno, Marta Maria Coelho

    2014-01-01

    OBJECTIVE: to relate neck circumference with metabolic syndrome and its criteria among college students.METHOD: cross-sectional study conducted with 702 college students in Fortaleza, CE, Brazil from September 2010 to June 2011. Socio-demographic data, waist circumference and neck circumference were collected together with blood pressure, fasting blood sugar, triglyceride levels, and HDL-C.RESULTS: 1.7% of the studied sample presented metabolic syndrome. Of these, 58.3% presented altered neck...

  6. Measuring waist circumference in disabled adults

    NARCIS (Netherlands)

    Waninge, Aly; Ligthart, K A M; Kramer, J; Hoeve, S; van der Schans, Cees; Haisma, Hinke

    2010-01-01

    To date, it is unknown whether waist circumference can be measured validly and reliably when a subject is in a supine position. This issue is relevant when international standards for healthy participants are applied to persons with severe intellectual, sensory, and motor disabilities. Thus, the

  7. Combined influence of leisure time physical activity and hip circumference on all-cause mortality

    DEFF Research Database (Denmark)

    Østergaard, Jane Nautrup; Grønbæk, Morten; Ängquist, Lars Henrik

    2013-01-01

    Hip circumference has been shown to be inversely associated with mortality. Muscle atrophy in the gluteofemoral region may be a possible explanation and thus physical activity is likely to play an important role. We aimed to estimate the combined effects of hip circumference and physical activity...... followed to 2009 in the Danish Civil Registration System, with 1.3% loss to follow-up and 2513 deaths. Hazard ratios (HR) were estimated for combinations of physical activity and hip circumference. Hip circumference was inversely associated with mortality irrespective of being physically active or not....... However, being physically active seemed to counterbalance some of the adverse health effects of a small hip circumference; when comparing inactive to active, the excess mortality at the 25(th) percentile of hip circumference is 40% in men (HR= 1.40, 95% CI: 1.14-1.72) and 33% in women (HR= 1.33, CI: 1...

  8. Relationship Between Neck Circumference and Epicardial Fat Thickness in a Healthy Male Population

    Directory of Open Access Journals (Sweden)

    Uğur Küçük

    2016-01-01

    Full Text Available Abstract Background: Epicardial fat is an upper body visceral fat depot that may play a significant role in the development of adverse metabolic and cardiovascular risk profiles. There is a significant direct relationship between the amount of epicardial fat and general body adiposity (body mass index, BMI, but data regarding subcutaneous adiposity is limited. Objective: We conducted a study to determine the association between neck circumference and epicardial fat thickness in healthy young male individuals, and assess their individual correlations with general body adiposity and cardiometabolic risk factors. Methods: One hundred consecutive male patients aged 18 years or older with no known major medical conditions were included in the study. All participants underwent detailed physical examination including measurement of blood pressure, weight, height, waist/hip ratio, and neck circumference. Blood was collected to determine fasting glucose and lipid parameters. A standard echocardiographic examination was performed with additional epicardial fat thickness determination. Results: Among 100 study participants, neck circumference correlated significantly with weight, waist circumference, BMI, blood glucose, serum total cholesterol, low-density (LDL-cholesterol, and triglycerides levels. No significant correlation was found between neck circumference and high-density lipoprotein (HDL-cholesterol levels. Neck circumference correlated moderately and positively with echocardiographic epicardial fat thickness. Conclusion: Among patients with low cardiometabolic risk, increased neck circumference was associated with increased epicardial fat thickness.

  9. Three-dimensional US assessment of hepatic volume, head circumference, and abdominal circumference in healthy and growth-restricted fetuses

    NARCIS (Netherlands)

    S.M. Boito; J.A.M. Laudij (Jacqueline); P.C. Struijk (Pieter); Th. Stijnen (Theo); J.W. Wladimiroff (Juriy)

    2002-01-01

    textabstractPURPOSE: To establish reproducibility and normal values for fetal hepatic volume and its significance in identification of fetal growth restriction relative to head and upper abdominal circumferences according to a cross-sectional study design. MATERIALS AND METHODS:

  10. Waist circumference does not predict circulating adiponectin levels in sub-Saharan women

    Directory of Open Access Journals (Sweden)

    Gautier Jean-François

    2007-10-01

    Full Text Available Abstract Background Because of previously reported ethnic differences in determinants and markers of obesity and related metabolic disorders, we sought to investigate circulating levels of adiponectin and their correlates in a sub-Saharan African (sSA population. Subjects and Methods We studied 70 non-diabetic volunteers (33M/37F living in Yaoundé, Cameroon, aged 24–69 yr, with BMI 20–42 kg/m2. In all participants we measured waist circumference and total body fat by bioimpedance, and obtained a fasting venous blood sample for measurement of plasma glucose, serum insulin and adiponectin concentrations. We performed a euglycaemic hyperinsulinaemic clamp in 1/4 subjects, and HOMAIR was used as surrogate of fasting insulin sensitivity index since it best correlates to clamp measurements. Results Males had lower adiponectin levels than females (8.8 ± 4.3 vs. 11.8 ± 5.5 μg/L. There was no significant correlation between adiponectin and total body fat (rs = -0.03; NS, whereas adiponectin was inversely correlated with waist circumference (rs = -0.39; p = 0.001. Adiponectin correlated negatively with insulin resistance (rs = -0.35; p = 0.01. In a regression analysis using fasting adiponectin concentration as the dependent variable, and age, HOMAIR, waist circumference, and fat mass as predictors, waist circumference (β = -3.30; p = 0.002, fat mass (β = -2.68; p = 0.01, and insulin resistance (β = -2.38; p = 0.02 but not age (β = 1.11; p = 0.27 were independent predictors of adiponectin. When considering gender, these relations persisted with the exception of waist circumference in females. Conclusion Adiponectin correlates in this study population are comparable to those observed in Caucasians with the exception of waist circumference in women. The metabolic significance of waist circumference is therefore questioned in sSA women.

  11. ELIPGRID-PC: Upgraded version

    International Nuclear Information System (INIS)

    Davidson, J.R.

    1995-12-01

    Evaluating the need for and the effectiveness of remedial cleanup at waste sites often includes finding average contaminant concentrations and identifying pockets of contamination called hot spots. The standard tool for calculating the probability of detecting pockets of contamination called hot spots has been the ELIPGRID code of singer and Wickman. The ELIPGRID-PC program has recently made this algorithm available for an IBM reg-sign personal computer (PC) or compatible. A new version of ELIPGRID-PC, incorporating Monte Carlo test results and simple graphics, is herein described. Various examples of how to use the program for both single and multiple hot spot cases are given. The code for an American National Standards Institute C version of the ELIPGRID algorithm is provided, and limitations and further work are noted. This version of ELIPGRID-PC reliably meets the goal of moving Singer's ELIPGRID algorithm to the PC

  12. BMI and waist circumference as indicators of health among Samoan women.

    Science.gov (United States)

    Novotny, Rachel; Nabokov, Vanessa; Derauf, Christopher; Grove, John; Vijayadeva, Vinutha

    2007-08-01

    High rates of obesity and chronic disease make establishment of effective indicators of risk for chronic disease important. The objective was to examine adequacy of anthropometric cut-off points as indicators of risk for chronic disease among Samoan women in Hawaii. A cross-sectional survey of 55 Samoan women 18 to 28 years of age that included blood lipids, cholesterol, and glucose (including after a 2-hour oral glucose test); anthropometry (weight, height, waist circumference); and DXA of body composition. Using the Centers for Disease Control and Prevention (CDC)/World Health Organization (WHO) cut-off points for BMI, 22% of women were overweight and 58% were obese. Cholesterol, lipid, and glucose values were all linearly related to DXA body fat, BMI, and waist circumference. BMI and waist circumference at WHO/NIH cut-off points predicted levels of blood lipids and glucose that indicate elevated risk for disease. WHO/NIH cut-off points for BMI and waist circumference reflect risk indicators of chronic disease among young Samoan women in Hawaii.

  13. PcInterlock: Implementation and Operational Experience with the Optics Interlock

    CERN Document Server

    Schaumann, Michaela; Fuchsberger, Kajetan; Wenninger, Jorg

    2018-01-01

    In 2016 the luminosity reach of the LHC was increased by reducing the β-function in the main collision points below the design value to β∗ = 40 cm. This was possible due to a review of the margins in the collimation hierarchy followed by the implementation of additional measures to ensure the phase advance in defined ranges around the circumference. The risk of damaging the triplet or the tertiary collimators (TCTs) close to the interaction points in the event of an asynchronous beam dump is minimized by including margins in the collimation hierarchy, which define the β∗-reach. By guaranteeing the phase advance within an acceptable tolerance between the beam dump kicker and the TCTs, those margins can be reduced and operation at lower β∗ becomes possible. A new interlock system on the quadrupole magnet currents was put in place to safeguard the stability of the phase advance. This note describes the technical implementation of this power-converter interlock (PcInterlock) and the strategies used to...

  14. Association between blood Pressure, waist circumference ...

    African Journals Online (AJOL)

    Objective: Blood pressure (BP) is one of the main cardiovascular risk indicators, but studies on its relationship with waist circumference, triglycerides and cholesterol are rare in low and middle income countries and even non-existent in some areas like the north of Cameroon. The aim of our study was to determine the ...

  15. Muscle function-dependent sarcopenia and cut-off values of possible predictors in community-dwelling Turkish elderly: calf circumference, midarm muscle circumference and walking speed.

    Science.gov (United States)

    Akın, S; Mucuk, S; Öztürk, A; Mazıcıoğlu, M; Göçer, Ş; Arguvanlı, S; Şafak, E D

    2015-10-01

    The aim of this study was to determine the prevalence of muscle strength-based sarcopenia and to determine possible predictors. This is a cross-sectional population-based study in the community-dwelling Turkish elderly. Anthropometric measurements, namely body height, weight, triceps skin fold (TSF), mid upper arm circumference (MUAC), waist circumference (WC) and calf circumference (CC), were noted. The midarm muscle circumference (MAMC) was calculated by using MUAC and TSF measurement. Sarcopenia was assessed, adjusted for body mass index (BMI) and gender, according to muscle strength. Physical performance was determined by 4 m walking speed (WS; m/s). The receiver operating curve analysis was performed to determine cut-offs of CC, MAMC and 4 m WS. A total of 879 elderly subjects, 50.1% of whom were female, were recruited. The mean handgrip strength (HGS) and s.d. was 24.2 (8.8) kg [17.9 (4.8) female, 30.6 (7.1) male]. The muscle function-dependent sarcopenia was 63.4% (female 73.5%, male 53.2%). The muscle mass-dependent sarcopenia for CC (sarcopenia. An adequate muscle mass may not mean a reliable muscle function. Muscle function may describe sarcopenia better compared with muscle mass. The CC, MAMC and 4 m WS cut-offs may be used to assess sarcopenia in certain age groups.

  16. PC-BLAS, PC Linear Algebra Subroutines

    International Nuclear Information System (INIS)

    Hanson, R.J.

    1989-01-01

    1 - Description of program or function: PC-BLAS is a highly optimized version of the Basic Linear Algebra Subprograms (BLAS), a standardized set of 38 routines that perform low-level operations on vectors of numbers in single- and double-precision real and complex arithmetic. Routines are included to find the index of the largest component of a vector, apply a Givens or modified Givens rotation, multiply a vector by a constant, determine the Euclidean length, perform a dot product, swap and copy vectors, and find the norm of a vector. 2 - Restrictions on the complexity of the problem: The number of components in any vector and the spacing or stride between their entries must not exceed 32,767 (2 15 -1). PC-BLAS will not work with an 80286 CPU operating in 'protected' mode

  17. Peak Pc Prediction in Conjunction Analysis: Conjunction Assessment Risk Analysis. Pc Behavior Prediction Models

    Science.gov (United States)

    Vallejo, J.J.; Hejduk, M.D.; Stamey, J. D.

    2015-01-01

    Satellite conjunction risk typically evaluated through the probability of collision (Pc). Considers both conjunction geometry and uncertainties in both state estimates. Conjunction events initially discovered through Joint Space Operations Center (JSpOC) screenings, usually seven days before Time of Closest Approach (TCA). However, JSpOC continues to track objects and issue conjunction updates. Changes in state estimate and reduced propagation time cause Pc to change as event develops. These changes a combination of potentially predictable development and unpredictable changes in state estimate covariance. Operationally useful datum: the peak Pc. If it can reasonably be inferred that the peak Pc value has passed, then risk assessment can be conducted against this peak value. If this value is below remediation level, then event intensity can be relaxed. Can the peak Pc location be reasonably predicted?

  18. Mid-upper arm circumference in pregnant women and its relation to birth weight

    Directory of Open Access Journals (Sweden)

    Ricalde Anamaría E.

    1998-01-01

    Full Text Available OBJECTIVE: In order to determine the relationship between some maternal anthropometric indicators and birth weight, crown-heel length and newborn's head circumference, 92 pregnant women were followed through at the prenatal service of hospital in S. Paulo, Brazil. MATERIAL AND METHOD: The following variables were established for the mother: weight, height, mid-upper arm circumference, pre-pregnancy weight, gestational weight gain and Quetelet's index. For the newborn the following variables were recorded: birth weight, crown-heel length, head circumference and gestational age by Dubowitz's method. RESULTS: Significant associations were noted between gestational age and newborn variables. In addition, maternal mid-arm circumference (MUAC and pre-pregnancy weight were found to be positively correlated to birth weight (r=0.399; r=0.378, respectively. The multivariate linear regression shows that gestational age, mother's arm circumference and pre-pregnancy weight continue to be significant predictors of birth weight. On the other hand, only gestational age and mother's age was associated with crown-heel length. Similarly MUAC was significantly associated with crown-heel length (r= 0.306; P=0.0030. CONCLUSION: Maternal mid-upper arm circumference is a potential indicator of maternal nutritional status. It could be used in association with other anthropometric measurements, instead of pre-pregnancy weight, as an alternative indicator to assess women at risk of poor pregnancy outcome.

  19. Mid-upper arm circumference in pregnant women and its relation to birth weight

    Directory of Open Access Journals (Sweden)

    Anamaría E. Ricalde

    1998-04-01

    Full Text Available OBJECTIVE: In order to determine the relationship between some maternal anthropometric indicators and birth weight, crown-heel length and newborn's head circumference, 92 pregnant women were followed through at the prenatal service of hospital in S. Paulo, Brazil. MATERIAL AND METHOD: The following variables were established for the mother: weight, height, mid-upper arm circumference, pre-pregnancy weight, gestational weight gain and Quetelet's index. For the newborn the following variables were recorded: birth weight, crown-heel length, head circumference and gestational age by Dubowitz's method. RESULTS: Significant associations were noted between gestational age and newborn variables. In addition, maternal mid-arm circumference (MUAC and pre-pregnancy weight were found to be positively correlated to birth weight (r=0.399; r=0.378, respectively. The multivariate linear regression shows that gestational age, mother's arm circumference and pre-pregnancy weight continue to be significant predictors of birth weight. On the other hand, only gestational age and mother's age was associated with crown-heel length. Similarly MUAC was significantly associated with crown-heel length (r= 0.306; P=0.0030. CONCLUSION: Maternal mid-upper arm circumference is a potential indicator of maternal nutritional status. It could be used in association with other anthropometric measurements, instead of pre-pregnancy weight, as an alternative indicator to assess women at risk of poor pregnancy outcome.

  20. Waist and hip circumferences and all-cause mortality: usefulness of the waist-to-hip ratio?

    DEFF Research Database (Denmark)

    Bigaard, J.; Frederiksen, K.; Tjønneland, A.

    2004-01-01

    inverse for both men and women, but only after adjustment for waist circumference, or BMI, or both. The mortality rate ratios of mutually adjusted waist and hip circumferences were 0.63 (95% CI: 0.56, 0.71), and 0.70 (95% CI: 0.63, 0.79) times higher per 10% larger hip circumference in men and women......, respectively, and 1.45 (95% CI: 1.34, 1.57) and 1.22 (95% CI: 1.14, 1.31) times higher per 10% larger waist circumference. The adequacy of the waist-to-hip ratio as a substitute for separate measurements of waist and hip circumferences depended on which other variables the analysis was adjusted for, indicating...... that the waist-to-hip ratio should be used with precaution. CONCLUSION: When mutually adjusted, waist and hip circumferences show opposite associations with all-cause mortality, probably due to different effects of adipose tissue in the abdominal and gluteofemoral regions. The waist-to-hip ratio cannot always...

  1. Thigh circumference and risk of heart disease and premature death: prospective cohort study

    DEFF Research Database (Denmark)

    Heitmann, Berit; Frederiksen, Peder

    2009-01-01

    OBJECTIVE: To examine associations between thigh circumference and incident cardiovascular disease and coronary heart disease and total mortality. DESIGN: Prospective observational cohort study with Cox proportional hazards model and restricted cubic splines. SETTING: Random subset of adults...... in Denmark. PARTICIPANTS: 1436 men and 1380 women participating in the Danish MONICA project, examined in 1987-8 for height, weight, and thigh, hip, and waist circumference, and body composition by impedance. MAIN OUTCOME MEASURES: 10 year incidence of cardiovascular and coronary heart disease and 12.5 years...... of follow-up for total death. RESULTS: A small thigh circumference was associated with an increased risk of cardiovascular and coronary heart diseases and total mortality in both men and women. A threshold effect for thigh circumference was evident, with greatly increased risk of premature death below...

  2. Repairing and Upgrading Your PC

    CERN Document Server

    Thompson, Robert

    2009-01-01

    Repairing and Upgrading Your PC delivers start-to-finish instructions, simple enough for even the most inexperienced PC owner, for troubleshooting, repairing, and upgrading your computer. Written by hardware experts Robert Bruce Thompson and Barbara Fritchman Thompson, this book covers it all: how to troubleshoot a troublesome PC, how to identify which components make sense for an upgrade, and how to tear it all down and put it back together. This book shows how to repair and upgrade all of your PC's essential components.

  3. The PC graphics handbook

    CERN Document Server

    Sanchez, Julio

    2003-01-01

    Part I - Graphics Fundamentals PC GRAPHICS OVERVIEW History and Evolution Short History of PC Video PS/2 Video Systems SuperVGA Graphics Coprocessors and Accelerators Graphics Applications State-of-the-Art in PC Graphics 3D Application Programming Interfaces POLYGONAL MODELING Vector and Raster Data Coordinate Systems Modeling with Polygons IMAGE TRANSFORMATIONS Matrix-based Representations Matrix Arithmetic 3D Transformations PROGRAMMING MATRIX TRANSFORMATIONS Numeric Data in Matrix Form Array Processing PROJECTIONS AND RENDERING Perspective The Rendering Pipeline LIGHTING AND SHADING Lightin

  4. PcToll2 positively regulates the expression of antimicrobial peptides by promoting PcATF4 translocation into the nucleus.

    Science.gov (United States)

    Lan, Jiang-Feng; Zhao, Li-Juan; Wei, Shun; Wang, Yuan; Lin, Li; Li, Xin-Cang

    2016-11-01

    Drosophila Toll and mammalian Toll-like receptors (TLRs) are a family of evolutionarily conserved immune receptors that play a crucial role in the first-line defense against intruded pathogens. Activating transcription factor 4 (ATF4), a member of the ATF/CREB transcription factor family, is an important factor that participates in TLR signaling and other physiological processes. However, in crustaceans, whether ATF4 homologs were involved in TLR signaling remains unclear. In the current study, we identified a Toll homolog PcToll2 and a novel ATF4 homolog PcATF4 from Procambarus clarkii, and analyzed the likely regulatory activity of PcATF4 in PcToll2 signaling. The complete cDNA sequence of PcToll2 was 4175 bp long containing an open reading frame of 2820 bp encoding a 939-amino acid protein, and the cDNA sequence of PcATF4 was 2027 bp long with an open reading frame of 1296 bp encoding a 431-amino acid protein. PcToll2 and human TLR4 shared the high identity and they were grouped into a cluster. Furthermore, PcToll2 had a close relationship with other shrimp TLRs that possessed potential antibacterial activity. PcToll2 was highly expressed in the hemocytes, heart and gills, while PcATF4 mainly distributed in gills. Upon challenge with Vibrio parahemolyticus, PcToll2 and PcATF4 together with the antimicrobial peptides of ALF1 and ALF2 were significantly up-regulated in the hemocytes, and the PcATF4 was translocated into the nucleus. After PcToll2 silencing and challenge with Vibrio, the translocation of PcATF4 into the nucleus was inhibited and the expression of ALF1 and ALF2 was reduced, but the expression of PcDorsal and PcSTAT was not affected. Furthermore, after PcATF4 knockdown and challenge with or without Vibrio, the expression of ALF1 and ALF2 was also decreased while the expression of PcToll2 was upregulated. These results suggested that PcToll2 might regulate the expression of ALF1 and ALF2 by promoting the import of PcATF4, instead of the routine

  5. Gender differences in waist circumference in Nigerian children ...

    African Journals Online (AJOL)

    Gender differences in waist circumference in Nigerian children. ... African Journal for Physical Activity and Health Sciences ... anthropometric tape according to the protocol of the International Society for the Advancement of Kinanthropometry ...

  6. Neck circumference might predict gestational diabetes mellitus in Han Chinese women: A nested case-control study.

    Science.gov (United States)

    He, Fang; He, Hua; Liu, Wenqi; Lin, Junyu; Chen, Bingjun; Lin, Yucong; Zhao, Yitao; Tao, Wen; Xia, Xuefeng

    2017-03-01

    A large neck circumference might be an indicator of metabolic syndrome and its components, and for certain patients is more practical as an index than waist circumference. The demarcation value for neck circumference that suggests metabolic syndrome appears to vary by ethnic group. Gestational diabetes mellitus is considered a component of metabolic syndrome in pregnant women. We investigated whether neck circumference in Han Chinese women is associated with gestational diabetes mellitus in early pregnancy, and determined a predictive demarcation value. A nested case-control study was carried out with 255 women aged 18-35 years. Gestational diabetes mellitus was diagnosed according to the criteria of the American Diabetes Association through a 2-h, 75-g oral glucose tolerance test. Of the total population, 41 (16%) women developed gestational diabetes mellitus by 24-28 weeks of gestation. Neck circumference at gestational week 16 positively correlated with pre-pregnancy waist circumference, bodyweight and body mass index, and maternal age (P = 0.029) and hemoglobin A1c at gestational week 24 (P ≤ 0.001). By binary logistic regression, neck circumference was an independent predictor of gestational diabetes mellitus (odds ratio 1.840, 95% confidence interval 1.040-3.254; P = 0.036). According to the receiver operating characteristic curve, for predicting gestational diabetes mellitus the optimal demarcation for neck circumference at gestational week 16 was 35.15 cm. Neck circumference is a viable tool to screen for gestational diabetes mellitus. In this population of pregnant Han Chinese women, a neck circumference of ≥35.15 cm was a predictor of gestational diabetes mellitus. © 2016 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  7. Height-adjusted percentiles evaluated central obesity in children and adolescents more effectively than just waist circumference.

    Science.gov (United States)

    Hosseini, Mostafa; Kelishadi, Roya; Yousefifard, Mahmoud; Qorbani, Mostafa; Bazargani, Behnaz; Heshmat, Ramin; Motlagh, Mohammad Esmail; Mirminachi, Babak; Ataei, Neamatollah

    2017-01-01

    We compared the prevalence of obesity based on both waist circumference for height and body mass index (BMI) in Iranian children and adolescents. Data on 13 120 children with a mean age of 12.45 ± 3.36 years (50.8% male) from the fourth Childhood and Adolescence Surveillance and Prevention of Adult Non-communicable Disease study were included. Measured waist circumference values were modelled according to age, gender and height percentiles. The prevalence of obesity was estimated using the 90th percentiles for both unadjusted and height-adjusted waist circumferences and compared with the World Health Organization BMI cut-offs. They were analysed further for short, average and tall children. Waist circumference values increased steadily with age. For short and average height children, the prevalence of obesity was higher when height-adjusted waist circumference was used. For taller children, the prevalence of obesity using height-adjusted waist circumference and BMI was similar, but lower than the prevalence based on measurements unadjusted for height. Height-adjusted waist circumference and BMI identified different children as having obesity, with overlaps of 69.47% for boys and 68.42% for girls. Just using waist circumference underestimated obesity in some Iranian children and measurements should be adjusted for height. ©2016 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  8. CoPc and CoPcF16 on gold: Site-specific charge-transfer processes

    Directory of Open Access Journals (Sweden)

    Fotini Petraki

    2014-04-01

    Full Text Available Interface properties of cobalt(II phthalocyanine (CoPc and cobalt(II hexadecafluoro-phthalocyanine (CoPcF16 to gold are investigated by photo-excited electron spectroscopies (X-ray photoemission spectroscopy (XPS, ultraviolet photoemission spectroscopy (UPS and X-ray excited Auger electron spectroscopy (XAES. It is shown that a bidirectional charge transfer determines the interface energetics for CoPc and CoPcF16 on Au. Combined XPS and XAES measurements allow for the separation of chemical shifts based on different local charges at the considered atom caused by polarization effects. This facilitates a detailed discussion of energetic shifts of core level spectra. The data allow the discussion of site-specific charge-transfer processes.

  9. Relationship between Waist Circumference and Elevation of Carotid Intima-media Thickness in Newly-diagnosed Diabetic Patients

    Institute of Scientific and Technical Information of China (English)

    ZHANG Lei; JIA Wei Ping; SHEN Yun; ZHOU Jian; PAN Jie Min; YU Hao Yong; CHEN Hai Bing; LI Qing; LI Ming; BAO Yu Qian

    2014-01-01

    Objective Waist circumference, as a brief indicator of visceral obesity, is associated with multi-metabolic disorders and cardiovascular diseases. The present study was aimed to find out the relationship between waist circumference and carotid intima media thickness (C-IMT), as well as the best waist circumference cutoff for identifying C-IMT elevation in Chinese male patients with newly-diagnosed diabetes. Methods Five hundred and seventy-eight patients from Department of Endocrinology and Metabolism in Shanghai Sixth People’s Hospital affiliated to Shanghai Jiao Tong University were enrolled. Both physical examination (for measurement of waist circumference) and carotid ultrasonography (for measurement of C-IMT) were performed. Results After grouping according to the quartiles of C-IMT, the waist circumference increased across all its quartiles. The waist circumference in 3rd and 4th quartiles (90.7±9.8 cm and 90.8±9.6 cm) was significant higher than in 1st and 2nd quartiles (P Conclusion Among newly-diagnosed diabetic male patients, waist circumference over 90 cm not only reflects sub-clinical atherosclerosis in early stage, but also predicts the progression of atherosclerosis.

  10. Hip circumference is associated with high density lipoprotein cholesterol response following statin therapy in hypertensive subjects.

    Science.gov (United States)

    Pio-Magalhães, J A; Ferreira-Sae, M C; Souza, F A; Grespan-Magossi, A M; Schreiber, R; Velloso, L A; Geloneze, B; Franchini, K G; Nadruz, W

    2011-10-01

    This report investigated the relationship between anthropometric measurements of body fat distribution and lipid response to statins in hypercholesterolemic hypertensive patients. We prospectively examined 129 subjects who used either simvastatin 20 mg/day (no.=83) or atorvastatin 10 mg/day (no.=46) for 3 months. Anthropometry included evaluation of body mass index, waist and hip circumferences, and waist-to-hip-ratio. Significant decreases in LDL (pcorrelation between waist circumference and HDLcholesterol levels was detected (r=-0.18; p=0.04). Conversely, a direct relationship between hip circumference and HDLcholesterol response to statins was found in the whole sample (r=0.24; p=0.006), while no other anthropometric measurement displayed significant correlation with lipid changes. The association between HDL-cholesterol response and hip circumference was further confirmed by stepwise regression analysis adjusted for baseline HDL-cholesterol levels, metabolic syndrome, body mass index, and waist circumference. Hip circumference, a surrogate marker of peripheral adiposity, is associated with HDL-cholesterol changes following statin therapy in hypertensive patients.

  11. Relationship between waist circumference, visceral fat and ...

    African Journals Online (AJOL)

    Results: The prevalence was higher in women for enlarged waist circumference according to the pathological IDF or NCEP / ATP III threshold (p < 0.0001) contrasting with lower rates for pathological accumulation of visceral fat in men (p = 0.0001). The highest values for sensitivity and specificity were obtained for a ...

  12. PC/104 Embedded IOCs at Jefferson Lab

    International Nuclear Information System (INIS)

    Yan, Jianxun; Allison, Trent; Witherspoon, Sue; Cuffe, Anthony

    2009-01-01

    Jefferson Lab has developed embedded IOCs based on PC/104 single board computers (SBC) for low level control systems. The PC/104 IOCs run EPICS on top of the RTEMS operating system. Two types of control system configurations are used in different applications, PC/104 SBC with commercial PC/104 I/O cards and PC/104 SBC with custom designed FPGA-based boards. RTEMS was built with CEXP shell to run on the PC/104 SBC. CEXP shell provides the function of dynamic object loading, which is similar to the widely used VxWorks operating system. Standard software configurations were setup for PC/104 IOC application development to provide a familiar format for new projects as well as ease the conversion of applications from VME based IOCs to PC/104 IOCs. Many new projects at Jefferson Lab are going to employ PC/104 SBCs as IOCs and some applications have already been running them for accelerator operations. The PC/104 - RTEMS IOC provides a free open source Real-Time Operating System (RTOS), low cost/maintenance, easily installed/ configured, flexible, and reliable solution for accelerator control and 12GeV Upgrade projects.

  13. Functional Analysis of Mouse G6pc1 Mutations Using a Novel In Situ Assay for Glucose-6-Phosphatase Activity and the Effect of Mutations in Conserved Human G6PC1/G6PC2 Amino Acids on G6PC2 Protein Expression.

    Directory of Open Access Journals (Sweden)

    Kayla A Boortz

    Full Text Available Elevated fasting blood glucose (FBG has been associated with increased risk for development of type 2 diabetes. Single nucleotide polymorphisms (SNPs in G6PC2 are the most important common determinants of variations in FBG in humans. Studies using G6pc2 knockout mice suggest that G6pc2 regulates the glucose sensitivity of insulin secretion. G6PC2 and the related G6PC1 and G6PC3 genes encode glucose-6-phosphatase catalytic subunits. This study describes a functional analysis of 22 non-synonymous G6PC2 SNPs, that alter amino acids that are conserved in human G6PC1, mouse G6pc1 and mouse G6pc2, with the goal of identifying variants that potentially affect G6PC2 activity/expression. Published data suggest strong conservation of catalytically important amino acids between all four proteins and the related G6PC3 isoform. Because human G6PC2 has very low glucose-6-phosphatase activity we used an indirect approach, examining the effect of these SNPs on mouse G6pc1 activity. Using a novel in situ functional assay for glucose-6-phosphatase activity we demonstrate that the amino acid changes associated with the human G6PC2 rs144254880 (Arg79Gln, rs149663725 (Gly114Arg and rs2232326 (Ser324Pro SNPs reduce mouse G6pc1 enzyme activity without affecting protein expression. The Arg79Gln variant alters an amino acid mutation of which, in G6PC1, has previously been shown to cause glycogen storage disease type 1a. We also demonstrate that the rs368382511 (Gly8Glu, rs138726309 (His177Tyr, rs2232323 (Tyr207Ser rs374055555 (Arg293Trp, rs2232326 (Ser324Pro, rs137857125 (Pro313Leu and rs2232327 (Pro340Leu SNPs confer decreased G6PC2 protein expression. In summary, these studies identify multiple G6PC2 variants that have the potential to be associated with altered FBG in humans.

  14. Upper arm circumference measurement for detecting overweight and obesity in children aged 6-7 years

    Directory of Open Access Journals (Sweden)

    Dewi Rosariah Ayu

    2017-02-01

    Full Text Available Background Obesity is a worldwide problem and is associated with increased risk of metabolic syndrome. Nutritional status in children has traditionally been determined by body mass index (BMI scores, but with limitations. Upper arm circumference measurement may be a better predictor of energy, protein, and fat storage, as well as a simpler method for screening overweight and obesity in children. Objective To determine the diagnostic value of upper arm circumference compared to BMI for detecting overweight and obesity in children aged 6-7 years. Methods This diagnostic study with a cross-sectional design was performed from September to October 2015 at 16 primary schools in Palembang, Indonesia. We measured the heights, weights, and upper arm circumferences, and calculated BMIs of 2,258 children. Receiver-operator characteristic (ROC curve analysis was used to find an optimal upper arm circumference cut-off point to detect overweight and obesity. Diagnostic value was calculated by using a 2x2 table analysis. Results The prevalences of overweight and obesity were 5.8% and 11.7%, respectively. The optimal upper arm circumference cut-off points for detecting overweight in children aged 6-7 years was 185 mm (sensitivity 88.1% and specificity 78.3%, and for obesity was 195 mm (sensitivity 90.15% and specificity 86.65%. Upper arm circumference had a strong correlation with BMI. Conclusion Upper arm circumference measurement is an accurate method fordistinguishing between normoweight, overweight, and obesity in children aged 6-7 years.

  15. PC'eren på arbejde. 3. udgave

    DEFF Research Database (Denmark)

    Andersen, Povl Erik Rostgård

    En generel og ikke-programspecifik introduktion til edb-området med speciel fokus på pc'er og pc-programmel.......En generel og ikke-programspecifik introduktion til edb-området med speciel fokus på pc'er og pc-programmel....

  16. IBM PC/IX operating system evaluation plan

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Granier, Martin; Hall, Philip P.; Triantafyllopoulos, Spiros

    1984-01-01

    An evaluation plan for the IBM PC/IX Operating System designed for IBM PC/XT computers is discussed. The evaluation plan covers the areas of performance measurement and evaluation, software facilities available, man-machine interface considerations, networking, and the suitability of PC/IX as a development environment within the University of Southwestern Louisiana NASA PC Research and Development project. In order to compare and evaluate the PC/IX system, comparisons with other available UNIX-based systems are also included.

  17. Heavier smoking may lead to a relative increase in waist circumference

    DEFF Research Database (Denmark)

    Morris, Richard W; Taylor, Amy E; Fluharty, Meg E

    2015-01-01

    in the CHRNA5-CHRNA3-CHRNB4 gene region) as a proxy for smoking heaviness, of the associations of smoking heaviness with a range of adiposity phenotypes. PARTICIPANTS: 148,731 current, former and never-smokers of European ancestry aged ≥ 16 years from 29 studies in the consortium for Causal Analysis Research...... in Tobacco and Alcohol (CARTA). PRIMARY OUTCOME MEASURES: Waist and hip circumferences, and waist-hip ratio. RESULTS: The data included up to 66,809 never-smokers, 43,009 former smokers and 38,913 current daily cigarette smokers. Among current smokers, for each extra minor allele, the geometric mean...... was lower for waist circumference by -0.40% (95% CI -0.57% to -0.22%), with effects on hip circumference, waist-hip ratio and body mass index (BMI) being -0.31% (95% CI -0.42% to -0.19), -0.08% (-0.19% to 0.03%) and -0.74% (-0.96% to -0.51%), respectively. In contrast, among never-smokers, these effects...

  18. biostatistical analysis of birth weight and head circumference

    African Journals Online (AJOL)

    URCHMAN

    hypothesis that birth weight is independent of head circumference; birth weight is ... small head size called Microcephaly or very slow growth rate may indicate that .... Decision is to reject H0 if the F distribution with K degrees of freedom in the ...

  19. BODY MASS INDEX AND WAIST CIRCUMFERENCE IN GREEK ADULTS

    Directory of Open Access Journals (Sweden)

    Mavrovounioti, Chr.

    2009-03-01

    Full Text Available The aim of the present study was to investigate overweight and obesity, in Greek adults. In the presentstudy, 110 men and women, 19- to 60 years old, took part. Measurements of subject’s height, body weight, andwaist circumference (WC were performed. BMI was used for the evaluation of the degree of overweight andobesity and WC for the evaluation of the degree of central obesity, according to the values for adults set byWorld Health Organisation (WHO. For the statistical analysis the statistic packet SPSS/PC version 12.0 forwindows was used. From data statistical analysis, it was found out that men had BMI 24.94+3.22 kg/m2 and WC90.78+13.24cm, while women had BMI 22.99+4.75 kg/m2 and WC 80.64+11.19cm. T-tests showed that theobserved differences between men and women in both BMI and WC were significant (t=2.51, p<0.05 andt=4.34, p<0.001, respectively. Additionally, it was found out that more than half of the men were overweightand/or obese (51.9%, while approximately the 1/5th of women were overweight and/or obese (21.5%. Chisquaretest showed that sex affects significantly the degree of overweight and obesity (x2=18.14, p<0.001.Moreover, men presented central obesity to a percentage of 11.1%, while women presented central obesity to a smaller percentage (3.60%. Consequently, in the present study, there were observed high percentages of overweight and obesity, as well as of central obesity, especially on men. Thus, a combination of an exercise program with a balanced diet is suggested in order to lead to a normal body weight and normal abdominal fat quantity for an enhanced quality of life without health disorders due to obesity.

  20. Junior PC-Kørekort

    DEFF Research Database (Denmark)

    Hansbøl, Mikala; Mathiasen, Helle

    udviklingsprojekt med forsøg med DANSK IT's Junior PC-kørekort® som metode og redskab til at evaluere og dokumentere elevernes IT-kompetencer. Projektet blev gennemført i perioden fra 2002-2003 og afsluttet i foråret 2003. Rapporten er baseret på kvalitative case studier af elever og læreres arbejde med Junior PC......-kørekort® prøverne. DANSK IT's Junior PC-kørekort® kan betragtes som et forsøg på at etablere en bestemt fælleskulturel tilgang til elevernes IT-kompetencer i folkeskolen. Ud fra et situeret læringsperspektiv problematiserer rapporten anvendelsen af de standardiserede prøver som metode til at dokumentere og evaluere...... elevernes IT-kompetencer. Rapporten (2MB) fylder 80 sider ekskl. bilag. Bemærk, at forskningsrapporten handler om Dansk IT's Junior PC-kørekort - ikke at forveksle med det IT-bevis for folkeskolens elever, som Undevisningsministeriet har udviklet. Dette IT-bevis koncept skiftede navn i januar 2004, hvor...

  1. Phosphatidylcholine (PC) biosynthesis in pancreatic islets of Langerhans

    International Nuclear Information System (INIS)

    Hoffman, J.M.; Laychock, S.G.

    1986-01-01

    Islets of Langerhans isolated from rat pancreata were incubated with [ 14 C]choline to determine the biosynthesis of PC by the CDP choline to determine the biosynthesis of PC by the CDPcholine pathway. Recovery of [ 14 C]PC in islet membranes was time-related, and stimulated by glucose (17mM) during 60 min. The rate of PC synthesis was constant during 60 min with glucose stimulation. In contrast, the sulfonylurea tolbutamide (2 mM) reduced the recovery of [ 14 C]choline in PC, and 8-bromo-cyclic AMP (5 mM) did not significantly affect [ 14 C]PC recovery. Incubation of islets in Ca 2+ -free medium enhanced glucose-stimulated recovery of [ 14 C]choline-labeled PC due to the inhibition of phospholipase and phospholipid hydrolysis. Inhibition of CTP:phosphocholine cytidylyltransferase with 5-deoxy-5'-isobutylthioadenosine (SIBA) reduced [ 14 C]PC levels and insulin release in a concentration dependent manner. Treatment with SIBA also reduced Mg 2+ -dependent Ca 2+ -ATPase activity in islet microsomes. Quantitation of membrane PC showed that glucose stimulation did not alter islet P levels. Thus, islet PC biosynthesis is linked to glucose stimulation and contributes to the maintenance of PC levels in membranes undergoing exocytosis and phospholipid hydrolysis. Adequate PC levels support Ca 2+ pump activity and secretory mechanisms

  2. THE EFFECT OF WAIST CIRCUMFERENCES MORE THAN NORMAL ON THE INCIDENT OF CORONARY HEART DISEASE

    Directory of Open Access Journals (Sweden)

    Pria Wahyu

    2017-07-01

    Full Text Available Introduction: Coronary heart disease is known as the most common disease that causes mortality in the world, one of the examination to identify the risks of coronary heart disease is measuring waist circumference. The purpose of this study was to identify correlation between large waist circumferences and the incident of coroner heart disease. Method: Design used in this study was analytic observational (retrospective with cross sectional approach. There were 63 respondents which sampling by simple random sampling. The independent variable was waist circumferences and the dependent variable was coronary heart disease. Data were collected by direct observation then analyzed by spearman correlation statistic test with significance level α≤0.05. Result: The result showed that waist circumferences more than normal had significant correlation with the incident of coronary heart disease (p=0.02. Analysis: It can be concluded that there was correlation between waist circumferences more than normal and the incident of coronary heart disease to the clients with coroner cardiac disease. Discussion: Earlier screening and detection is needed to prevent coronary heart disease.

  3. Strength and cardiometabolic risk in young adults: The mediator role of aerobic fitness and waist circumference.

    Science.gov (United States)

    Díez-Fernández, A; Martínez-Vizcaíno, V; Torres-Costoso, A; Cañete García-Prieto, J; Franquelo-Morales, P; Sánchez-López, M

    2018-02-22

    The aim of this study was to analyze the mediation role of cardiorespiratory fitness and waist circumference in the association between muscular strength and cardiometabolic risk. A cross-sectional study involved first-year college students (n = 370) from a Spanish public university was performed. We measured weight, height, waist circumference, blood pressure, biochemical variables, maximum handgrip strength assessment, and cardiorespiratory fitness. We calculated handgrip dynamometry/weight and a previously validated cardiometabolic risk index. Analysis of covariance models was conducted to test differences in cardiometabolic risk values across muscular strength, cardiorespiratory fitness, and waist circumference categories, controlling for confounders. Hayes' PROCESS macro was used for the multiple mediation analysis. The relationship between muscular strength and cardiometabolic risk did not remain significant (c' = 1.76 [1.4]; P > .05) in a multiple serial bootstrapped mediation model including cardiorespiratory fitness and waist circumference as mediators when controlling for age and sex. According to the indirect effect, the significant paths in the model mediating this relationship between muscular strength and cardiometabolic risk index were as follows: muscular strength → waist circumference → cardiometabolic risk index (-4.899; 95% CI: -6.690; -3.450) and muscular strength → cardiorespiratory fitness → waist circumference → cardiometabolic risk index (-0.720; 95% CI: -1.316; -0.360). Both cardiorespiratory fitness and waist circumference mediate the association between muscular strength and cardiometabolic risk in young adults. Thus, our results place cardiorespiratory fitness and waist circumference as the main targets of physical activity programmes aimed at preventing cardiometabolic diseases. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Waist circumference as a predictor for blood glucose levels in adults

    Directory of Open Access Journals (Sweden)

    Shinta L Hardiman

    2016-02-01

    Full Text Available Anthropometric indexes such as body mass index (BMI, waist circumference (WC, hip ciucumference (HC, and waist–hip ratio (WHR, are all useful anthropometric measurements to provide important information on blood glucose concentrations. The aim of this study was to determine different anthropometric measurements, in particular BMI, waist circumference, hip circumference and waist-to-hip ratio, in their ability to predict the blood glucose levels in men and women 40 to 60. A cross-sectional study was conducted on a sample of 44 men and 127 women aged 40 to 50 who lived in Cipete Selatan subdistrict, South Jakarta. Blood glucose levels was assessed and anthropometric measurements comprising BMI, WC, HC, WHR were collected. Multiple linear regression analysis was used to determine the best predictor for blood glucose levels. The study showed that the prevalence of DM type 2 was 25.7% and the prevalence was higher in men (40.9% compared to women (23.5%. The significant predictive variables in the simple regression analysis were age and waist circumference. Multiple linear regression showed that after adjustment for age, WC was positively associated with blood glucose levels. Standardized a value was 0.172 (p=0.026. WC predict blood glucose levels, beyond that explained by traditional diabetic risk factors and BMI. These findings provide support for the recommendation that WC be a routine measure for identification of diabetes mellitus type 2 in men and women aged 40 to 60 years.

  5. Circumference reduction and cellulite treatment with a TriPollar radiofrequency device: a pilot study.

    Science.gov (United States)

    Manuskiatti, W; Wachirakaphan, C; Lektrakul, N; Varothai, S

    2009-07-01

    A wide variety of treatments for circumference reduction and cellulite are available, but most procedures offer suboptimal clinical effect and/or delayed therapeutic outcome. Objective To determine the safety and efficacy of the TriPollar radiofrequency device for cellulite treatment and circumference reduction. Thirty-nine females with cellulite received eight weekly TriPollar treatments. Treatment areas included the abdomen, thighs, buttocks and arms. Subjects were evaluated using standardized photographs and measurements of body weight, circumference, subcutaneous thickness, and skin elasticity of the treatment sites at baseline, immediately after and 4 weeks after the final treatment. Physicians' evaluation of clinical improvement scores using a quartile grading scale was recorded. Thirty-seven patients (95%) completed the treatment protocol. There was significant circumference reduction of 3.5 and 1.7 cm at the abdomen (P = 0.002) and thigh (P = 0.002) regions, respectively. At 4 weeks after the last treatment, the average circumferential reductions of the abdomen and thighs were sustained. No significant circumferential reductions of the buttocks and arms at the last treatment visit compared to baseline were demonstrated (P = 0.138 and 0.152, respectively). Quartile grading scores correlating to approximately 50% improvement in cellulite appearance were noted. Tripollar radiofrequency provided beneficial effects on the reduction of abdomen and thigh circumference and cellulite appearance.

  6. Head Circumference in Autism, Asperger Syndrome and ADHD

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2002-06-01

    Full Text Available Occipitofrontal circumference (OFC, measured at birth and after 16 months of age, was compared in 50 consecutive patients with Asperger syndrome, 50 diagnosed with autistic disorder, and 50 with ADHD and followed at the Department of Child and Adolescent Psychiatry, Goteborg University, Sweden.

  7. Comparison of an increased waist circumference with a positive hydrogen breath test as a clinical predictor of lactose intolerance.

    Science.gov (United States)

    Zapata-Castilleja, Carlos A; Montes-Tapia, Fernando F; Treviño-Garza, Consuelo; Martínez-Cobos, María C; García-Cantú, Jesús; Arenas-Fabbri, Vincenzo; de la O-Escamilla, Norma; de la O-Cavazos, Manuel

    2017-04-01

    Lactose intolerance is a common disease in pediatrics, and its wrong diagnosis will lead to morbidity. The primary objective of this study was to assess the usefulness of an increased waist circumference during the hydrogen breath test as a predictor of lactose intolerance. The secondary objective was to analyze the impact of body mass index, waist circumference measurement, and age on the abdominal distension of patients with lactose intolerance. A total of 138 subjects aged 3 to 15 years were included. They underwent serial measurements of the waist circumference and hydrogen levels in the breath every 30 minutes over 3 hours during the hydrogen breath test. Out of the entire sample, 35 (25.4%) patients had lactose intolerance. An increase of 0.85 cm in waist circumference compared to the baseline waist circumference results in a sensitivity of 88% and a specificity of 85% to predict lactose intolerance (odds ratio: 42.14, 95% confidence interval: 13.08-135.75, p ≤ 0.001). The body mass index and waist circumference measurement did not affect abdominal distension (p= not significant); however, age modified the time of distension. A 0.85 cm increase in waist circumference compared to the baseline waist circumference during the hydrogen breath test is a useful parameter for the diagnosis of lactose intolerance in pediatrics. Variations in relation to body mass index and waist circumference did not affect the usefulness of an increased waist circumference, unlike age.

  8. Maternal waist circumference as a prediction of children's stunted ...

    African Journals Online (AJOL)

    2014-05-08

    May 8, 2014 ... Stunted Child and Overweight Mother (SCOM) pairs in a South African setting. After a ... this study measured waist circumference, while the Mexican group ... predictor of the mothers' children's metabolic syndrome status, but.

  9. Quality assessment of platelet concentrates prepared by platelet rich plasma-platelet concentrate, buffy coat poor-platelet concentrate (BC-PC and apheresis-PC methods

    Directory of Open Access Journals (Sweden)

    Singh Ravindra

    2009-01-01

    Full Text Available Background: Platelet rich plasma-platelet concentrate (PRP-PC, buffy coat poor-platelet concentrate (BC-PC, and apheresis-PC were prepared and their quality parameters were assessed. Study Design: In this study, the following platelet products were prepared: from random donor platelets (i platelet rich plasma - platelet concentrate (PRP-PC, and (ii buffy coat poor- platelet concentrate (BC-PC and (iii single donor platelets (apheresis-PC by different methods. Their quality was assessed using the following parameters: swirling, volume of the platelet concentrate, platelet count, WBC count and pH. Results: A total of 146 platelet concentrates (64 of PRP-PC, 62 of BC-PC and 20 of apheresis-PC were enrolled in this study. The mean volume of PRP-PC, BC-PC and apheresis-PC was 62.30±22.68 ml, 68.81±22.95 ml and 214.05±9.91 ml and ranged from 22-135 ml, 32-133 ml and 200-251 ml respectively. The mean platelet count of PRP-PC, BC-PC and apheresis-PC was 7.6±2.97 x 1010/unit, 7.3±2.98 x 1010/unit and 4.13±1.32 x 1011/unit and ranged from 3.2-16.2 x 1010/unit, 0.6-16.4 x 1010/unit and 1.22-8.9 x 1011/unit respectively. The mean WBC count in PRP-PC (n = 10, BC-PC (n = 10 and apheresis-PC (n = 6 units was 4.05±0.48 x 107/unit, 2.08±0.39 x 107/unit and 4.8±0.8 x 106/unit and ranged from 3.4 -4.77 x 107/unit, 1.6-2.7 x 107/unit and 3.2 - 5.2 x 106/unit respectively. A total of 26 units were analyzed for pH changes. Out of these units, 10 each were PRP-PC and BC-PC and 6 units were apheresis-PC. Their mean pH was 6.7±0.26 (mean±SD and ranged from 6.5 - 7.0 and no difference was observed among all three types of platelet concentrate. Conclusion: PRP-PC and BC-PC units were comparable in terms of swirling, platelet count per unit and pH. As expected, we found WBC contamination to be less in BC-PC than PRP-PC units. Variation in volume was more in BC-PC than PRP-PC units and this suggests that further standardization is required for preparation of BC-PC

  10. Neck Circumference Positively Related with Central Obesity and Overweight in Turkish University Students: A Preliminary Study.

    Science.gov (United States)

    Özkaya, İsmail; Tunçkale, Aydın

    2016-06-01

    According to the World Health Organization, central obesity is increasing alarmingly worldwide. Neck circumference is a relatively new method of differentiating between normal and abnormal fat distribution. The aim of this study is to determine the association between neck circumference and central obesity in young Turkish male and female university students. A community of university students based cross-sectional study was conducted on 319 males and 838 females and investigated the association between neck circumference and other anthropometric variables by gender. In male subjects, the neck circumference revealed a positive correlation with the body mass index (r=0.684, pobesity, is also applicable to university students. Copyright© by the National Institute of Public Health, Prague 2015.

  11. Head circumference, education and risk of dementia: findings from the Nun Study.

    Science.gov (United States)

    Mortimer, James A; Snowdon, David A; Markesbery, William R

    2003-08-01

    To examine the prevalence of dementia associated with having a smaller brain, lower education or both of these characteristics, 294 Catholic sisters were assessed annually for dementia. Sixty participants died and their brains were evaluated to determine fulfillment of neuropathological criteria for Alzheimer's disease (AD). Lower educational attainment and the interaction of smaller head circumference with lower education were associated with the presence of dementia, controlling for age and the presence of one or more apolipoprotein E-epsilon 4 alleles. By contrast, neither low educational attainment nor head circumference was significantly associated with fulfillment of neuropathological criteria for AD. Individuals having both low education and small head circumference were four times as likely to be demented as the rest of the sample. The findings suggest that higher education and larger head size, alone or in combination, may reduce the risk of expressing dementia in late life.

  12. PC clusters at CERN's PC farm

    CERN Multimedia

    Patrice Loïez

    2001-01-01

    These Linux-based PC clusters are mainly used for batch and interactive data processing. When the LHC starts operation in 2008, it will produce enough data every year to fill a stack of CDS 20 km tall, so high quality processing is required. To further facilitate this the LHC Computing Grid (LCG) has been set up to share processing power between facilities around the world.

  13. Waist circumference and body composition in relation to all-cause mortality in middle-aged men and women

    DEFF Research Database (Denmark)

    Bigaard, J.; Frederiksen, K.; Tjønneland, A.

    2005-01-01

    of waist circumference and body composition (body fat and fat-free mass), mutually adjusted, to all-cause mortality. DESIGN: A Danish prospective cohort study with a median follow-up period of 5.8 y. SUBJECTS: In all, 27 178 men and 29 875 women, born in Denmark, aged 50-64 y, and without diagnosis...... of cancer at the time of invitation. MEASUREMENTS: Waist circumference and body composition estimated from impedance measurements. Cox's regression models were used to estimate the mortality rate ratios (RR). RESULTS: Waist circumference was strongly associated with all-cause mortality after adjustment...... for body composition; the mortality RR was 1.36 (95% confidence intervals (CI): 1.22-1.52) times higher per 10% larger waist circumference among men and 1.30 (95% CI: 1.17-1.44) times higher among women. Adjustment for waist circumference eliminated the association between high values of the body fat mass...

  14. PC Mobile Warrior with a built-in cellular phone; Keitai denwa naizogata PC 'Mobile warrior

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    A PC Mobile Warrior with a built-in cellular phone has been developed from PC Libretto through cooperation with the NTT DoCoMo. The new personal computer incorporates into itself some distinguished mobile PC features such as Wake On Radio and Wake On Ring which are defined by MCPC (Mobile Computing Promotion Consortium). Wake On Radio is a function that activates the PC upon entry into the zone from outside, and Wake On Ring is another function that does the same upon arrival of a phone call. Installed on these lower order functions are an application program for automatic transmission of stored e-mails making use of the former function and another for automatic reception of FAX messages making use of the latter function. (translated by NEDO)

  15. Validation of the Microlife WatchBP Home blood pressure device in pregnancy for medium and large arm circumferences.

    Science.gov (United States)

    Clark, Katherine; Snowball, Olivia; Nzelu, Diane; Kay, Polly; Kametas, Nikos A

    2018-06-01

    The Microlife WatchBP Home automated blood pressure device was assessed for accuracy in pregnant women of medium (arm circumference. The British Hypertension Society validation protocol was modified for the purpose of this study to include women with arm circumference of less than 32 cm (N=51) and greater than or equal to 32 cm (N=46) as two separate arms. The device achieved an overall A/A grade for medium arm circumference and B/A grade for large arm circumference. The mean±SD device-observer difference was 1.7±6.2 and -0.4±4.4 for systolic and diastolic blood pressure, respectively, for medium arm circumference and 3.0±8.5 and 1.5±5.1, respectively, for large arm circumference. When all women with pre-eclampsia from both groups were pooled (N=23), the device achieved an overall grade of A/A with mean differences of 2.1±7.2 for systolic blood pressure and 1.0±5.6 for diastolic blood pressure. The Microlife WatchBP Home automated blood pressure device can be recommended for use in pregnant women of all gestations, including those with pre-eclampsia. However, caution is needed for women with large arm circumferences.

  16. PC Pricer

    Data.gov (United States)

    U.S. Department of Health & Human Services — The PC Pricer is a tool used to estimate Medicare PPS payments. The final payment may not be precise to how payments are determined in the Medicare claims processing...

  17. ELIPGRID-PC: A PC program for calculating hot spot probabilities

    International Nuclear Information System (INIS)

    Davidson, J.R.

    1994-10-01

    ELIPGRID-PC, a new personal computer program has been developed to provide easy access to Singer's 1972 ELIPGRID algorithm for hot-spot detection probabilities. Three features of the program are the ability to determine: (1) the grid size required for specified conditions, (2) the smallest hot spot that can be sampled with a given probability, and (3) the approximate grid size resulting from specified conditions and sampling cost. ELIPGRID-PC also provides probability of hit versus cost data for graphing with spread-sheets or graphics software. The program has been successfully tested using Singer's published ELIPGRID results. An apparent error in the original ELIPGRID code has been uncovered and an appropriate modification incorporated into the new program

  18. Relationship of total body fat mass to weight-bearing bone volumetric density, geometry, and strength in young girls.

    Science.gov (United States)

    Farr, Joshua N; Chen, Zhao; Lisse, Jeffrey R; Lohman, Timothy G; Going, Scott B

    2010-04-01

    Understanding the influence of total body fat mass (TBFM) on bone during the peri-pubertal years is critical for the development of future interventions aimed at improving bone strength and reducing fracture risk. Thus, we evaluated the relationship of TBFM to volumetric bone mineral density (vBMD), geometry, and strength at metaphyseal and diaphyseal sites of the femur and tibia of young girls. Data from 396 girls aged 8-13 years from the "Jump-In: Building Better Bones" study were analyzed. Bone parameters were assessed using peripheral quantitative computed tomography (pQCT) at the 4% and 20% distal femur and 4% and 66% distal tibia of the non-dominant leg. Bone parameters at the 4% sites included trabecular vBMD, periosteal circumference, and bone strength index (BSI), while at the 20% femur and 66% tibia, parameters included cortical vBMD, periosteal circumference, and strength-strain index (SSI). Multiple linear regression analyses were used to assess associations between bone parameters and TBFM, controlling for muscle cross-sectional area (MCSA). Regression analyses were then repeated with maturity, bone length, physical activity, and ethnicity as additional covariates. Analysis of covariance (ANCOVA) was used to compare bone parameters among tertiles of TBFM. In regression models with TBFM and MCSA, associations between TBFM and bone parameters at all sites were not significant. TBFM explained very little variance in all bone parameters (0.2-2.3%). In contrast, MCSA was strongly related (p<0.001) to all bone parameters, except cortical vBMD. The addition of maturity, bone length, physical activity, and ethnicity did not alter the relationship between TBFM and bone parameters. With bone parameters expressed relative to total body mass, ANCOVA showed that all outcomes were significantly (p<0.001) greater in the lowest compared to the middle and highest tertiles of TBFM. Although TBFM is correlated with femur and tibia vBMD, periosteal circumference, and

  19. PrPC from stem cells to cancer

    Directory of Open Access Journals (Sweden)

    Séverine eMartin-Lannerée

    2014-09-01

    Full Text Available The cellular prion protein PrPC was initially discovered as the normal counterpart of the pathological scrapie prion protein PrPSc, the main component of the infectious agent of Transmissible Spongiform Encephalopathies. While clues as to the physiological function of this ubiquitous protein were greatly anticipated from the development of knock-out animals, PrP-null mice turned out to be viable and to develop without major phenotypic abnormalities. Notwithstanding, the discovery that hematopoietic stem cells from PrP-null mice have impaired long-term repopulating potential has set the stage for investigating into the role of PrPC in stem cell biology. A wealth of data have now exemplified that PrPC is expressed in distinct types of stem cells and regulates their self-renewal as well as their differentiation potential. A role for PrPC in the fate restriction of embryonic stem cells has further been proposed. Paralleling these observations, an overexpression of PrPC has been documented in various types of tumours. In line with the contribution of PrPC to stemness and to the proliferation of cancer cells, PrPC was recently found to be enriched in subpopulations of tumour-initiating cells. In the present review, we summarize the current knowledge of the role played by PrPC in stem cell biology and discuss how the subversion of its function may contribute to cancer progression.

  20. The readout performance evaluation of PowerPC

    International Nuclear Information System (INIS)

    Chu Yuanping; Zhang Hongyu; Zhao Jingwei; Ye Mei; Tao Ning; Zhu Kejun; Tang Suqiu; Guo Yanan

    2003-01-01

    PowerPC, as a powerful low-cost embedded computer, is one of the very important research objects in recent years in the project of BESIII data acquisition system. The researches on the embedded system and embedded computer have achieved many important results in the field of High Energy Physics especially in the data acquisition system. The one of the key points to design an acquisition system using PowerPC is to evaluate the readout ability of PowerPC correctly. The paper introduce some tests for the PowerPC readout performance. (authors)

  1. [Calf circumference and its association with gait speed in elderly participants at Peruvian Naval Medical Center].

    Science.gov (United States)

    Díaz Villegas, Gregory Mishell; Runzer Colmenares, Fernando

    2015-01-01

    To evaluate the association between calf circumference and gait speed in elderly patients 65 years or older at Geriatric day clinic at Peruvian Centro Médico Naval. Cross-sectional, retrospective study. We assessed 139 participants, 65 years or older at Peruvian Centro Médico Naval including calf circumference, gait speed and Short Physical Performance Battery. With bivariate analyses and logistic regression model we search for association between variables. The age mean was 79.37 years old (SD: 8.71). 59.71% were male, the 30.97% had a slow walking speed and the mean calf circumference was 33.42cm (SD: 5.61). After a bivariate analysis, we found a calf circumference mean of 30.35cm (SD: 3.74) in the slow speed group and, in normal gait group, a mean of 33.51cm (SD: 3.26) with significantly differences. We used logistic regression to analyze association with slow gait speed, founding statistically significant results adjusting model by disability and age. Low calf circumference is associated with slow speed walk in population over 65 years old. Copyright © 2014. Published by Elsevier Espana.

  2. Implementasi Penggunaan Smartphone Android untuk Control PC (Personal Computer

    Directory of Open Access Journals (Sweden)

    Imam Solikin

    2018-05-01

    Full Text Available The purpose of this research is to simplify the control of personal computer (PC such as control pointer, keyboard control and make it easier to do the presentation by controlling the slide remotely using smartphone through wifi connections facility. The smartphone is a multimedia phone that combines PC functionality with microprocessor, memory, and built-in modem to produce smart smartphone gadgets. Problems that occur when performing a presentation such as PC control, control pointer and keyboard control for input should be close to the PC so it is less than optimal in explaining the material. The model used in implementing the use of Android Smartphone for PC control is a conceptual model consisting of several stages: potential and problems, data collection, system testing, test results, and system implementation or implementation. From the results of PC control research can be done by connecting the Smartphone with a PC via wifi network so that PC can be controlled remotely. PC control application is an application that can control PC remotely connected via wifi network connection. Benefits derived from this research make it easy to mengedalikan PC remotely such as facilitate in the percentage and control pointer and control Keyboard for input process.

  3. Installation and implementation of PC COSYMA; PC COSYMAn kaeyttoeoenotto ja soveltaminen

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, J [VTT Energy, Espoo (Finland). Nuclear Energy

    1995-12-01

    COSYMA is a probabilistic reactor accident consequence assessment model developed in the 1980`s by the research institutes of the EC countries, primarily by NRPB and KfK. In 1993 a simplified version of the program was released to be implemented on a PC. In the study the PC COSYMA program was applied to calculate as the end points nuclide concentrations, doses received, numbers of health effects, areas affected by countermeasures and other results related to countermeasure strategies. Some results are compared with the results obtained by the ARANO program developed by VTT Energy (Technical Research Centre of Finland) to quarantee proper interpretation of the application. (15 refs.).

  4. PC application in DIII-D neutral beam operation

    International Nuclear Information System (INIS)

    Gladd, A.S.

    1986-01-01

    An IBM PC/AT has been implemented to improve operation of the DIII-D neutral beams. The PC system provides centralization of all beam data with reasonable access for online shot-to-shot control and analysis. The PC hardware was configured to interface all four neutral beam host mini-computers, support multi-tasking, and provide storage for approximately one month's accumulation of beam data. The PC software is composed of commercial packages used for performance and statistical analysis (i.e. LOTUS 123, PC PLOT, etc.) host communications software (i.e. PCLINK, KERMIT, etc.) and applications developed software utilizing FORTRAN and BASIC. The objectives of this paper are to describe the implementation of the PC system, the methods of integrating the various software packages, and the scenario for online control and analysis

  5. Lattice design for an ILC damping ring with 3 km circumference

    International Nuclear Information System (INIS)

    Wolski, Andrzej

    2004-01-01

    We describe a simple lattice that meets the specifications for the damping times and horizontal and longitudinal emittances for the International Linear Collider (ILC) damping rings. The circumference of a little over 3 km leads to a bunch spacing of around 3 ns, which will require advances in kicker technology for injection and extraction. We present the lattice design, and initial results of studies of the acceptance and collective effects. With the high bunch charge and close spacing, the ion and electron cloud effects are expected to be severe; however, the simple structure of the lattice allows for easy variation of the circumference and bunch spacing, which may make it useful for future investigations

  6. The prediction of in-hospital mortality by mid-upper arm circumference

    DEFF Research Database (Denmark)

    Opio, Martin Otyek; Namujwiga, Teopista; Nakitende, Imaculate

    2018-01-01

    There are few reports of the association of nutritional status with in-hospital mortality of acutely ill medical patients in sub-Saharan Africa. This is a prospective observational study comparing the predictive value of mid-upper arm circumference (MUAC) of 899 acutely ill medical patients...... patients in a resource-poor hospital in sub-Saharan Africa....... admitted to a resource-poor sub-Saharan hospital with mental alertness, mobility and vital signs. Mid-upper arm circumference ranged from 15 cm to 42 cm, and 12 (24%) of the 50 patients with a MUAC less than 20 cm died (OR 4.84, 95% CI 2.23-10.37). Of the 237 patients with a MUAC more than 28 cm only six...

  7. Central odontogenic fibroma (simple type) in a four year old boy: Atypical cone-beam computed tomographic appearance with periosteal reaction

    Energy Technology Data Exchange (ETDEWEB)

    Anbiaee, Najme; Ebrahimnejad, Hamed; Sanaei, Alireza [Dept. of , Oral and Maxillofacial Radiology, Maxillofacial Diseases Research Center, School of Dentistry, Mashhad University of Medical Sciences, Mashhad (Iran, Islamic Republic of)

    2015-06-15

    Central odontogenic fibroma (COF) is a rare benign tumor that accounts for 0.1% of all odontogenic tumors. A case of COF (simple type) of the mandible in a four-year-old boy is described in this report. The patient showed asymptomatic swelling in the right inferior border of the lower jaw for one week. A panoramic radiograph showed a poorly-defined destructive unilocular radiolucent area. Cone-beam computed tomography showed expansion and perforation of the adjacent cortical bone plates. A periosteal reaction with the Codman triangle pattern was clearly visible in the buccal cortex. Since the tumor had destroyed a considerable amount of bone, surgical resection was performed. No recurrence was noted.

  8. Substrate analysis of the Pneumocystis carinii protein kinases PcCbk1 and PcSte20 using yeast proteome microarrays provides a novel method for Pneumocystis signalling biology.

    Science.gov (United States)

    Kottom, Theodore J; Limper, Andrew H

    2011-10-01

    Pneumocystis carinii (Pc) undergoes morphological transitions between cysts and trophic forms. We have previously described two Pc serine/threonine kinases, termed PcCbk1 and PcSte20, with PcSte20 belonging to a family of kinases involved in yeast mating, while PcCbk1 is a member of a group of protein kinases involved in regulation of cell cycle, shape, and proliferation. As Pc remains genetically intractable, knowledge on specific substrates phosphorylated by these kinases remains limited. Utilizing the phylogenetic relatedness of Pc to Saccharomyces cerevisiae, we interrogated a yeast proteome microarray containing >4000 purified protein based peptides, leading to the identification of 18 potential PcCbk1 and 15 PcSte20 substrates (Z-score > 3.0). A number of these potential protein substrates are involved in bud site selection, polarized growth, and response to mating α factor and pseudohyphal and invasive growth. Full-length open reading frames suggested by the PcCbk1 and PcSte20 protoarrays were amplified and expressed. These five proteins were used as substrates for PcCbk1 or PcSte20, with each being highly phosphorylated by the respective kinase. Finally, to demonstrate the utility of this method to identify novel PcCbk1 and PcSte20 substrates, we analysed DNA sequence data from the partially complete Pc genome database and detected partial sequence information of potential PcCbk1 kinase substrates PcPxl1 and PcInt1. We additionally identified the potential PcSte20 kinase substrate PcBdf2. Full-length Pc substrates were cloned and expressed in yeast, and shown to be phosphorylated by the respective Pc kinases. In conclusion, the yeast protein microarray represents a novel crossover technique for identifying unique potential Pc kinase substrates. Copyright © 2011 John Wiley & Sons, Ltd.

  9. The comparison of CAP88-PC version 2.0 versus CAP88-PC version 1.0

    International Nuclear Information System (INIS)

    Yakubovich, B.A.; Klee, K.O.; Palmer, C.R.; Spotts, P.B.

    1997-12-01

    40 CFR Part 61 (Subpart H of the NESHAP) requires DOE facilities to use approved sampling procedures, computer models, or other approved procedures when calculating Effective Dose Equivalent (EDE) values to members of the public. Currently version 1.0 of the approved computer model CAP88-PC is used to calculate EDE values. The DOE has upgraded the CAP88-PC software to version 2.0. This version provides simplified data entry, better printing characteristics, the use of a mouse, and other features. The DOE has developed and released version 2.0 for testing and comment. This new software is a WINDOWS based application that offers a new graphical user interface with new utilities for preparing and managing population and weather data, and several new decay chains. The program also allows the user to view results before printing. This document describes a test that confirmed CAP88-PC version 2.0 generates results comparable to the original version of the CAP88-PC program

  10. Feature of extradosed PC bridge and its design; Daihenshin keburu PC kyo no tokucho to sono sekkei

    Energy Technology Data Exchange (ETDEWEB)

    Komiya, M. [Japan Bridge and Structure Institute Inc., Tokyo (Japan)

    1997-03-31

    A PC bridge with the eccentricity of the external cable increased by protruding the deviated member to the outside of the beam for more effective use of the external cable is called a `PC bridge with tendons of large eccentricity.` The extradosed bridge of main beam/cable joint type is a PC bridge with the external cable arranged via a tower-shaped eccentric member provided at the intermediate support, and resembles morphologically a cable stayed bridge having a very low tower. There are two types of extradosed bridges, i.e. a type with concrete coated external cable (cable stayed slab bridge) and the other with non-coated external cable (external cable stayed bridge). Features, structural planning and designing of the general external cable stayed bridge are shown. The features are the possession of intermediate characteristics of those of the PC beam bridge and the PC cable stayed bridge from the viewpoints of structural property, workability, economic efficiency, and scenic property. Outline of the plan, selection of structural data, design of the external cable, and structural characteristics in the ultimate state are discussed. 19 refs., 18 figs., 15 tabs.

  11. Waist circumference, BMI, and lung function in 8-year-old children : The PIAMA birth cohort study

    NARCIS (Netherlands)

    Bekkers, Marga B. M.; Wijga, Alet H.; de Jongste, Johan C.; Kerkhof, Marjan; Postma, Dirkje; Gehring, Ulrike; Smit, Henriette A.; Brunekreef, Bert

    Background Body mass index (BMI) and waist circumference (WC) may be associated with lung function in children, as observed in adults. Methods Height, weight, waist circumference, and lung function (FVC and FEV1) were measured during a medical examination in 1,058 eight-year-old children

  12. Building the perfect PC

    CERN Document Server

    Thompson, Robert Bruce

    2006-01-01

    This popular Build-It-Yourself (BIY) PC book covers everything you want to know about building your own system: Planning and picking out the right components, step-by-step instructions for assembling your perfect PC, and an insightful discussion of why you'd want to do it in the first place. Most big brand computers from HP, Dell and others use lower-quality components so they can meet their aggressive pricing targets. But component manufacturers also make high-quality parts that you can either purchase directly, or obtain through distributors and resellers. Consumers and corporations

  13. Residential proximity to urban centres, local-area walkability and change in waist circumference among Australian adults.

    Science.gov (United States)

    Sugiyama, Takemi; Niyonsenga, Theo; Howard, Natasha J; Coffee, Neil T; Paquet, Catherine; Taylor, Anne W; Daniel, Mark

    2016-12-01

    Consistent associations have been observed between macro-level urban sprawl and overweight/obesity, but whether residential proximity to urban centres predicts adiposity change over time has not been established. Further, studies of local-area walkability and overweight/obesity have generated mixed results. This study examined 4-year change in adults' waist circumference in relation to proximity to city centre, proximity to closest suburban centre, and local-area walkability. Data were from adult participants (n=2080) of a cohort study on chronic conditions and health risk factors in Adelaide, Australia. Baseline data were collected in 2000-03 with a follow-up in 2005-06. Multilevel regression models examined in 2015 the independent and joint associations of the three environmental measures with change in waist circumference, accounting for socio-demographic covariates. On average, waist circumference rose by 1.8cm over approximately 4years. Greater distance to city centre was associated with a greater increase in waist circumference. Participants living in distal areas (20km or further from city centre) had a greater increase in waist circumference (mean increase: 2.4cm) compared to those in proximal areas (9km or less, mean increase: 1.2cm). Counterintuitively, living in the vicinity of a suburban centre was associated with a greater increase in adiposity. Local-area walkability was not significantly associated with the outcome. Residential proximity to city centre appears to be protective against excessive increases in waist circumference. Controlled development and targeted interventions in the urban fringe may be needed to tackle obesity. Additional research needs to assess behaviours that mediate relationships between sprawl and obesity. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Organic photovoltaic effects depending on CuPc layer thickness

    International Nuclear Information System (INIS)

    Hur, Sung Woo; Kim, Tae Wan; Chung, Dong Hoe; Oh, Hyun Seok; Kim, Chung Hyeok; Lee, Joon Ung; Park, Jong Wook

    2004-01-01

    Organic photovoltaic effects were studied in device structures of ITO/CuPc/Al and ITO/CuPc/C 60 /BCP/Al by varying the CuPc layer thickness. Since the exciton diffusion length is relatively short in organic semiconductors, a study on the thickness-dependent photovoltaic effects is important. The thickness of the CuPc layer was varied from 10 nm to 50 nm. We found that the optimum CuPc layer thickness was around 40 nm from the analysis of the current density-voltage characteristics in an ITO/CuPc/Al photovoltaic cell. The efficiency of the device shows that the multi-layered heterojunction structure is more appropriate for photovoltaic cells.

  15. Comparative evaluation of the relative efficacy of the free mucosal graft and periosteal fenestration for increasing the vestibular depth - A clinical study

    Directory of Open Access Journals (Sweden)

    Nisha Yadav

    2014-01-01

    Full Text Available Purpose: The aim of the present study was to compare the periosteal fenestration (PF and free mucosal graft (FMG techniques in mandibular anterior region to increase the vestibular depth. Methodology: A total of 20 systemically healthy cases (10 patients in each group with shallow vestibular depth and reduced width of attached gingiva in lower anterior region were included in the present study. Clinical parameters recorded included Gingival index (GI, Plaque index (PI, Oral hygiene index simplified (OHI S, Vestibular depth (VD, width of attached gingiva and post operative discomfort. Findings: The results at the end of 3 months showed that the mean GI, PI, OHI S decreased significantly and remained low throughout the study period. The mean gain in percentage of vestibular depth at the end of 3 months for group 1(PF was 48.4% with relapse of 7.2% from the baseline. For group 2 (FMG, the mean gain in percentage of vestibular depth at the end of 3 months for was 50% with relapse of 6.2% from the baseline. The mean gain in percentage of attached gingiva at 3 months for group 1 and 2 was 65.9% and 74%, respectively. In comparison of group 1 and 2, group 2 showed better results in terms of increasing the vestibular depth and attached gingiva than group 1 although the intergroup comparison was not statistically significant. Conclusion: When aim of the clinician is to treat a patient with shallow vestibule together with reduced width of attached gingiva, the use of periosteal fenestration yields similar results to that of FMG.

  16. Leo II PC

    Data.gov (United States)

    Kansas Data Access and Support Center — LEO II is a second-generation software system developed for use on the PC, which is designed to convert location references accurately between legal descriptions and...

  17. Association of head circumference and shoulder dystocia in macrosomic neonates.

    Science.gov (United States)

    Larson, Austin; Mandelbaum, David E

    2013-04-01

    To determine whether asymmetric macrosomia (disproportionately large body size in comparison to head circumference) could be demonstrated in a population of infants suffering shoulder dystocia during delivery relative to those that did not suffer from shoulder dystocia. A case-control study was conducted as a retrospective chart review over 3 years at a large maternity hospital in an urban setting. Among infants over 4,000 g, those that suffered from shoulder dystocia during delivery had a smaller mean head circumference than infants of a similar size that did not suffer from shoulder dystocia. A statistically significant difference was also present when cases of documented gestational diabetes were excluded. Asymmetric macrosomia is more likely to be present in a population of infants who suffered shoulder dystocia during delivery. This knowledge could be used in designing tools to predict which pregnancies are at highest risk for shoulder dystocia during delivery.

  18. Surface-type nonvolatile electric memory elements based on organic-on-organic CuPc-H2Pc heterojunction

    International Nuclear Information System (INIS)

    Karimov, Khasan S.; Muqeet Rehman, M.; Zameer Abbas, S.; Ahmad, Zubair; Touati, Farid; Mahroof-Tahir, M.

    2015-01-01

    A novel surface-type nonvolatile electric memory elements based on organic semiconductors CuPc and H 2 Pc are fabricated by vacuum deposition of the CuPc and H 2 Pc films on preliminary deposited metallic (Ag and Cu) electrodes. The gap between Ag and Cu electrodes is 30–40 μm. For the current–voltage (I–V) characteristics the memory effect, switching effect, and negative differential resistance regions are observed. The switching mechanism is attributed to the electric-field-induced charge transfer. As a result the device switches from a low to a high-conductivity state and then back to a low conductivity state if the opposite polarity voltage is applied. The ratio of resistance at the high resistance state to that at the low resistance state is equal to 120–150. Under the switching condition, the electric current increases ∼ 80–100 times. A comparison between the forward and reverse I–V characteristics shows the presence of rectifying behavior. (paper)

  19. Predicting absolute risk of type 2 diabetes using age and waist circumference values in an aboriginal Australian community.

    Directory of Open Access Journals (Sweden)

    Odewumi Adegbija

    Full Text Available To predict in an Australian Aboriginal community, the 10-year absolute risk of type 2 diabetes associated with waist circumference and age on baseline examination.A sample of 803 diabetes-free adults (82.3% of the age-eligible population from baseline data of participants collected from 1992 to 1998 were followed-up for up to 20 years till 2012. The Cox-proportional hazard model was used to estimate the effects of waist circumference and other risk factors, including age, smoking and alcohol consumption status, of males and females on prediction of type 2 diabetes, identified through subsequent hospitalisation data during the follow-up period. The Weibull regression model was used to calculate the absolute risk estimates of type 2 diabetes with waist circumference and age as predictors.Of 803 participants, 110 were recorded as having developed type 2 diabetes, in subsequent hospitalizations over a follow-up of 12633.4 person-years. Waist circumference was strongly associated with subsequent diagnosis of type 2 diabetes with P<0.0001 for both genders and remained statistically significant after adjusting for confounding factors. Hazard ratios of type 2 diabetes associated with 1 standard deviation increase in waist circumference were 1.7 (95%CI 1.3 to 2.2 for males and 2.1 (95%CI 1.7 to 2.6 for females. At 45 years of age with baseline waist circumference of 100 cm, a male had an absolute diabetic risk of 10.9%, while a female had a 14.3% risk of the disease.The constructed model predicts the 10-year absolute diabetes risk in an Aboriginal Australian community. It is simple and easily understood and will help identify individuals at risk of diabetes in relation to waist circumference values. Our findings on the relationship between waist circumference and diabetes on gender will be useful for clinical consultation, public health education and establishing WC cut-off points for Aboriginal Australians.

  20. Electronic transitions and band offsets in C60:SubPc and C60:MgPc on MoO3 studied by modulated surface photovoltage spectroscopy

    International Nuclear Information System (INIS)

    Fengler, S.; Dittrich, Th.; Rusu, M.

    2015-01-01

    Electronic transitions at interfaces between MoO 3 layers and organic layers of C 60 , SubPc, MgPc, and nano-composite layers of SubPc:C 60 and MgPc:C 60 have been studied by modulated surface photovoltage (SPV) spectroscopy. For all systems, time dependent and modulated SPV signals pointed to dissociation of excitons at the MoO 3 /organic layer interfaces with a separation of holes towards MoO 3 . The highest occupied molecular orbital (HOMO)-lowest unoccupied molecular orbital (LUMO) gaps (E HL ) of C 60 , SubPc, and MgPc and the effective E HL of SubPc:C 60 and MgPc:C 60 were measured. The offsets between the LUMO (ΔE L ) or HOMO (ΔE H ) bands were obtained with high precision and amounted to 0.33 or 0.73 eV for SubPc:C 60 , respectively, and to −0.33 or 0.67 eV for MgPc:C 60 , respectively. Exponential tails below E HL and most pronounced sub-bandgap transitions were characterized and ascribed to disorder and transitions from HOMO bands to unoccupied defect states

  1. Measurement of scrotal circumference in beef bulls in Rio Grande do Sul

    Directory of Open Access Journals (Sweden)

    S.R.O Menegassi

    2011-02-01

    Full Text Available The variability of scrotal circumference and the effects of age and breed as well as the relationship between testicular weight (TW, scrotal circumference (SC, and live weight (BW were investigated in bulls. Devon, Polled Hereford, and Red Angus breeds showed higher SC values than the other British, Continental, Synthetic, and Zebu studied breeds. The percentage of culled bulls because of low SC ranged from 7.01 to 24.25%. The increase of SC was proportional to the increase in TW and they were highly correlated (r²= 0.90. The results suggest that SC in young bulls is the best way to predict TW and, therefore, a useful tool for their selection

  2. Experience using EPICS on PC platforms

    International Nuclear Information System (INIS)

    Hill, J.O.; Kasemire, K.U.

    1997-03-01

    The Experimental Physics and Industrial Control System (EPICS) has been widely adopted in the accelerator community. Although EPICS is available on many platforms, the majority of implementations have used UNIX workstations as clients, and VME- or VXI-based processors for distributed input output controllers. Recently, a significant portion of EPICS has been ported to personal computer (PC) hardware platforms running Microsoft's operating systems, and also Wind River System's real time vxWorks operating system. This development should significantly reduce the cost of deploying EPICS systems, and the prospect of using EPICS together with the many high quality commercial components available for PC platforms is also encouraging. A hybrid system using both PC and traditional platforms is currently being implemented at LANL for LEDA, the low energy demonstration accelerator under construction as part of the Accelerator Production of Tritium (APT) project. To illustrate these developments the authors compare their recent experience deploying a PC-based EPICS system with experience deploying similar systems based on traditional (UNIX-hosted) EPICS hardware and software platforms

  3. Ion and solvent diffusion and ion conduction of PC-DEC and PC-DME binary solvent electrolytes of LiN(SO2CF3)2

    International Nuclear Information System (INIS)

    Hayamizu, Kikuko; Aihara, Yuichi

    2004-01-01

    Two binary mixed solvent systems typically used for lithium batteries were studied by measuring the self-diffusion coefficients of the solvent, lithium ion and anion, independently by using the multi-nuclear pulsed field-gradient spin-echo (PGSE) 1 H, 7 Li and 19 F NMR method. One system was propylene carbonate (PC) and diethyl carbonate (DEC) system and the other binary system was PC and 1,2-dimethoxyethane (DME), and the lithium salt used was LiN(SO 2 CF 3 ) 2 (LiTFSI). The relative ratio of the PC was changed from zero (pure DME and DEC) to 100% (pure PC) in the DME-PC and the DEC-PC systems, respectively. The self-diffusion coefficients of the solvents were measured with and without the lithium salt, and the two solvents had almost the same diffusion coefficient in the DEC-PC system, while DME diffused faster than PC in the DME-PC system. In the electrolytes the solvents diffused the fastest, followed by the anion with the lithium ion diffusing the slowest. The degree of ion dissociation was estimated for each electrolyte by comparing the ionic conductivities estimated from the ion diffusion and those measured directly by the electrochemical method

  4. Salinomycin Exerts Anticancer Effects on PC-3 Cells and PC-3-Derived Cancer Stem Cells In Vitro and In Vivo

    Directory of Open Access Journals (Sweden)

    Yunsheng Zhang

    2017-01-01

    Full Text Available Salinomycin is an antibiotic isolated from Streptomyces albus that selectively kills cancer stem cells (CSCs. However, the antitumor mechanism of salinomycin is unclear. This study investigated the chemotherapeutic efficacy of salinomycin in human prostate cancer PC-3 cells. We found that cytotoxicity of salinomycin to PC-3 cells was stronger than to nonmalignant prostate cell RWPE-1, and exposure to salinomycin induced G2/M phage arrest and apoptosis of PC-3 cells. A mechanistic study found salinomycin suppressed Wnt/β-catenin pathway to induce apoptosis of PC-3 cells. An in vivo experiment confirmed that salinomycin suppressed tumorigenesis in a NOD/SCID mice xenograft model generated from implanted PC-3 cells by inhibiting the Wnt/β-catenin pathway, since the total β-catenin protein level was reduced and the downstream target c-Myc level was significantly downregulated. We also showed that salinomycin, but not paclitaxel, triggered more apoptosis in aldehyde dehydrogenase- (ALDH- positive PC-3 cells, which were considered as the prostate cancer stem cells, suggesting that salinomycin may be a promising chemotherapeutic to target CSCs. In conclusion, this study suggests that salinomycin reduces resistance and relapse of prostate tumor by killing cancer cells as well as CSCs.

  5. PC based 8-parameter data acquisition system

    International Nuclear Information System (INIS)

    Gupta, J.D.; Naik, K.V.; Jain, S.K.; Pathak, R.V.; Suman, B.

    1989-01-01

    Multiparameter data acquisition (MPA) systems which analyse nuclear events with respect to more than one property of the event are essential tools for the study of some complex nuclear phenomena requiring analysis of time coincident spectra. For better throughput and accuracy each parameter is digitized by its own ADC. A stand alone low cost IBM PC based 8-parameter data acquisition system developed by the authors makes use of Address Recording technique for acquiring data from eight 12 bit ADC's in the PC Memory. Two memory buffers in the PC memory are used in ping-pong fashion so that data acquisition in one bank and dumping of data onto PC disk from the other bank can proceed simultaneously. Data is acquired in the PC memory through DMA mode for realising high throughput and hardware interrupt is used for switching banks for data acquisition. A comprehensive software package developed in Turbo-Pascal offers a set of menu-driven interactive commands to the user for setting-up system parameters and control of the system. The system is to be used with pelletron accelerator. (author). 5 figs

  6. Monte Carlo tests of the ELIPGRID-PC algorithm

    International Nuclear Information System (INIS)

    Davidson, J.R.

    1995-04-01

    The standard tool for calculating the probability of detecting pockets of contamination called hot spots has been the ELIPGRID computer code of Singer and Wickman. The ELIPGRID-PC program has recently made this algorithm available for an IBM reg-sign PC. However, no known independent validation of the ELIPGRID algorithm exists. This document describes a Monte Carlo simulation-based validation of a modified version of the ELIPGRID-PC code. The modified ELIPGRID-PC code is shown to match Monte Carlo-calculated hot-spot detection probabilities to within ±0.5% for 319 out of 320 test cases. The one exception, a very thin elliptical hot spot located within a rectangular sampling grid, differed from the Monte Carlo-calculated probability by about 1%. These results provide confidence in the ability of the modified ELIPGRID-PC code to accurately predict hot-spot detection probabilities within an acceptable range of error

  7. The link between BMI and waist circumference in northern Iranian ...

    African Journals Online (AJOL)

    Background and Objectives: Waist circumference and not body mass index explains a greater variance in obesity-related health risk. The present study assesses the link between BMI and WC in Iranian adults. Methods: In a population based cross- sectional study on 3600 adults, northern Iran, we investigated the link ...

  8. Association of Milk and Dairy Products Consumption During Pregnancy with Fetal and Neonatal Head Circumferences: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Razieh Karimbeiki

    2016-11-01

    Full Text Available Context Milk and dairy products consumed by mothers seem to be effective for fetal and neonatal anthropometric measurements, because they contain various nutrients. Objectives The aim of this study was to systematically review the influence of milk and dairy products consumption by mothers on fetal and neonatal head circumferences. Data Sources Systematic searches were conducted in electronic databases including PubMed/MEDLINE, Scopus, ISI, Ovid, Embase, Medlib, Google Scholar, clinical trials and Cochrane central register of clinical trials. Study Selection All studies that assessed the relationship between milk and dairy products consumption in healthy females during pregnancy and fetal and neonatal head circumferences were included in our systematic review. Finally, seven studies were relevant that included five cohort studies, one cross-sectional study and one randomized clinical trial. Data Extraction This systematic review was performed based on the preferred reporting item for systematic reviews and meta-analysis (PRISMA statement recommendation, and for quality assessment, the Newcastle-Ottawa scale (NOS for cohort studies, the adapted NOS for a cross-sectional study and the Jadad quality assessment score for a randomized clinical trial, were used. Results Seven studies that comprised of more than 50000 pregnant females were included in this review. One cohort study, one cross-sectional study and one randomized controlled trial study showed that milk or dairy products consumption by pregnant mothers was not associated with neonatal birth head circumference, while three cohort studies reported that maternal milk or dairy products intake had a positive effect on neonatal birth head circumference. Two cohort studies showed that there was no relationship between maternal milk or dairy products consumption and fetal head circumference while a cross-sectional study reported that there was a positive relationship between milk or dairy products

  9. Hip circumference and cardiovascular morbidity and mortality in men and women

    DEFF Research Database (Denmark)

    Heitmann, Berit L; Frederiksen, Peder; Lissner, Lauren

    2004-01-01

    to 1988) participated in the Danish MONICA (MONItoring trends and determinants of CArdiovascular disease) project, with measurements of height, weight, and hip and waist circumference taken. Through personal identification numbers, incidence of coronary heart disease (CHD) and cardiovascular disease (CVD...

  10. Poster session ELIPGRID-PC

    International Nuclear Information System (INIS)

    Davidson, J.R.

    1995-01-01

    ELIPGRID-PC, a new personal computer program, has been developed to provide easy access to Singer's ELIPGRID algorithm for hot-spot detection probabilities. Three features of the program are the ability to determine: (1) the grid size required for specified conditions, (2) the smallest hot spot that can be sampled with a given probability, and (3) the approximate grid size resulting from specified conditions and sampling cost. ELIPGRID-PC also provides probability of detection versus cost data for graphing with spreadsheets or graphics software. The program has been successfully tested using Singer's published ELIPGRID results. An apparent error in the published ELIPGRID code has been uncovered and an appropriate modification incorporated into the new program

  11. [Determination of arm circumference for correct measurement of blood pressure. Results of an intervention study].

    Science.gov (United States)

    Oliveras Puig, A; Dalfó-Pibernat, A; Jdid Rosàs, N; Mayor Isaac, E; Pérez-Romero, L; Gibert Llorach, E; Dalfó-Baqué, A

    2015-01-01

    To assess the effectiveness of an intervention to promote standardized arm circumference measurement as way to choose appropriate cuff size to measure blood pressure. A before-after intervention study was performed in a basic health care area in Barcelona. Doctors, nurses and pharmacy staff participated by filling out an anonymous self-administered questionnaire pre- and post-intervention (3m). Variables included: demographics, type of professional, years since they finished their studies, availability of different cuff sizes, if arm circumference measurement were obtained or not, knowledge about the cutoff values for each cuff size and type of blood pressure monitor. The written results were given to the participants and presented in sessions. Pre- and post-intervention: 74.3 and 67.3% answered the questionnaires (P=ns), respectively. Determination of arm circumference varied from 1.3 to 19.1% (P=.009). A total of 37.3% and 44.1% declared that they had 2 or more available cuff sizes (P=ns). Knowledge about the correct measurement of the cuffs was 2.7 to 33.8% regarding the standard cuff size (P=.0198) and 0 to 23.5% for obese subjects (P<.05). When more than one cuff was available, reasons for the choice went from: «making a rough guess» or «when velcro stops sticking» before and after the intervention. All blood pressure devices in our primary health care center were electronic and automatic as were those of the 9 pharmacies. The intervention increased the determination of arm circumference prior to the reading of the blood pressure and the knowledge about the cutoff interval for standard and obese cuff size after intervention. There was greater availability of different sized cuffs. Despite this, the choice of the appropriate cuff size was not made based on arm circumference. Copyright © 2014 SEHLELHA. Published by Elsevier Espana. All rights reserved.

  12. Erect penile length and circumference dimensions of 1,661 sexually active men in the United States.

    Science.gov (United States)

    Herbenick, Debby; Reece, Michael; Schick, Vanessa; Sanders, Stephanie A

    2014-01-01

    Penile size continues to receive popular and empirical attention. Little is known about the process of self-measurement and whether the behaviors a man engages in to become erect for self-measurement are associated with his erect penile dimensions. The article aims to assess men's erect penile dimensions in a study in which the men would presumably be motivated to report accurate information about their penis size; and to explore associations between men's erect penile dimensions, their method of measurement, and their demographics. Data are from an Internet-based baseline phase of a large prospective daily diary study that compared men's use of a standard-sized condom to men's use of a condom sized to fit their erect penis. The main outcomes are participant characteristics, activities engaged in during self-measurement process, and self-reported erect penile length and circumference. For this sample of 1,661 men, the mean erect penile length was 14.15 cm (SD = 2.66; range = 4 to 26 cm), and the mean erect penile circumference was 12.23 cm (SD = 2.23; range = 3 to 19). Participant characteristics were not associated with measured length or circumference. Most men measured their penis while alone, using hand stimulation to become erect. In this sample of men who measured their erect penile length and circumference for the purposes of receiving a condom sized to fit their erect penis, we found a mean erect penile length of 14.15 cm and a mean erect penile circumference of 12.23 cm. The self-reported erect penile dimensions in this study are consistent with other penile dimension research. Also, findings suggest that mode of getting an erection may influence erect penile dimensions. Additionally, how a man becomes erect for self-measurement may be associated with his erect penile length and/or circumference. © 2013 International Society for Sexual Medicine.

  13. PC-Reactor-core transient simulation code

    International Nuclear Information System (INIS)

    Nakata, H.

    1989-10-01

    PC-REATOR, a reactor core transient simulation code has been developed for the real-time operator training on a IBM-PC microcomputer. The program presents capabilities for on-line exchange of the operating parameters during the transient simulation, by friendly keyboard instructions. The model is based on the point-kinetics approximation, with 2 delayed neutron percursors and up to 11 decay power generating groups. (author) [pt

  14. Neck Circumference as a Predictor of Adiposity among Healthy and Obese Children

    Directory of Open Access Journals (Sweden)

    Nayera E. Hassan

    2015-11-01

    Full Text Available BACKGROUND: Obesity, particularly in the upper part of body, is a major health problem. Because body mass index (BMI does not adequately describe regional adiposity, other indices of body fatness are being explored. OBJECTIVES: To determine if neck circumference is a valid measure of adiposity (fat distribution among group of Egyptian children. SUBJECTS AND METHODS: This is a cross sectional study, included 50 obese subjects, aged 7 - 12 years recruited from Endocrine, obesity and Metabolism Pediatric Unit at Children Hospital, Cairo University and 50 healthy children, age and sex matched. All children were subjected to blood pressure assessment (systolic SBP and diastolic DBP, and anthropometric assessment (body weight, height, neck circumference (NC, waist (WC and hip (HC circumferences, and skin fold thicknesses at three sites: biceps, triceps and sub scapular. BMI [weight (kg/height (m2] was calculated. RESULTS: In healthy females, significant associations were detected between NC and SBP, DBP and all anthropometric measurements. However, in healthy males NC was not significantly associated with BMI, SBP and DBP. In the obese group; both sexes; insignificant association was found between NC and SBP, DBP, BMI and skinfold thickness. CONCLUSION: NC is related to fat distribution among normal healthy female children. However, this relation disappears with increasing adiposity. The results do not support the use of NC as a useful screening tool for childhood obesity.

  15. IBM-PC-based reactor neutronics analysis package

    International Nuclear Information System (INIS)

    Nigg, D.W.; Wessol, D.E.; Grimesey, R.A.; Parsons, D.K.; Wheeler, F.J.; Yoon, W.Y.; Lake, J.A.

    1985-01-01

    Technical advances over the past few years have led to a situation where a wide range of complex scientific computations can now be done on properly configured microcomputers such as the IBM-PC (personal computer). For a number of reasons, including security, economy, and user convenience, the development of a comprehensive system of reactor neutronics codes suitable for operation on the IBM-PC has been undertaken at the Idaho National Engineering Laboratory (INEL). It is anticipated that a PC-based code system could also have wide applicability in the nuclear engineering education community since conversion of software generated by national laboratories and others to college and university mainframe hardware has historically been a time-consuming process that has sometimes met with only limited success. This paper discusses the philosophy behind the INEL reactor neutronics PC code system and describes those parts of the system that are currently complete, those that are now under development, and those that are still in the planning stage

  16. Comparison of Marginal Circumference of Two Different Pre-Crimped Stainless Steel Crowns for Primary Molars After Re-Crimping.

    Science.gov (United States)

    Afshar, Hossein; Ghandehari, Mehdi; Soleimani, Banafsheh

    2015-12-01

    It is not clear what type of pre-crimped crown is more successful in achieving greater marginal adaptation following re-crimping. This study aimed to assess the changes in the circumference of 3M ESPE and MIB pre-crimped stainless steel crowns (SSCs) for the primary maxillary and mandibular first and second molars following re-crimping. This was an in-vitro, experimental study. Initial photographs were obtained from the margins of 3M and MIB SSCs for the upper and lower primary molars using a digital camera. Crown margins were crimped by applying 0.2N force using 114 and 137 pliers. Post-crimping photographs were also obtained and the changes in crown circumference after crimping were calculated using AutoCad software. The percentage of reduction in the circumference of crowns for each tooth was statistically analyzed based on the type of crown using student t-test. The effect of crown design and the associated teeth on the decreased circumference percentage was statistically analyzed by two-sided ANOVA. The percentage of reduction in lower E SSC circumference was 3.71±0.39% in MIB and 6.29±0.62% in 3M crowns. These values were 3.55±0.55% and 7.15±1.13% for the lower Ds, and 3.95±0.43 and 6.24±0.85% for the upper Ds, respectively. For the upper Es, these values were found to be 3.12±0.65% and 5.14±0.94%, respectively. For each tooth, a significant difference was found between MIB and 3M SSCs in terms of the percentage of reduction in crown circumference following crimping. The magnitude of this reduction was smaller in MIB compared to 3M SSCs (P<0.001). Considering the significant reduction in the marginal circumference of precrimped SSCs following re-crimping, it appears that this manipulation must be necessarily performed for MIB and 3M pre-crimped SSCs. By using 3M SSCs, higher marginal adaptation can be achieved following crimping.

  17. Evaluation of a Chest Circumference-Adapted Protocol for Low-Dose 128-Slice Coronary CT Angiography with Prospective Electrocardiogram Triggering

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Chenying; Wang, Zufei; Ji, Jiansong; Wang, Hailin; Hu, Xianghua; Chen, Chunmiao [Department of Radiology, Lishui Central Hospital, The Fifth Affiliated Hospital of Wenzhou Medical College, Lishui, Zhejiang 323000 (China)

    2015-11-01

    To assess the effect of chest circumference-adapted scanning protocol on radiation exposure and image quality in patients undergoing prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). One hundred-eighty-five consecutive patients, who had undergone prospective ECG triggering CCTA with a 128-slice CT, were included in the present study. Nipple-level chest circumference, body weight and height were measured before CT examinations. Patients were divided into four groups based on kV/ref·mAs = 100/200, 100/250, 120/200, and 120/250, when patient's chest circumference was ≤ 85.0 (n = 56), 85.0-90.0 (n = 53), 90.0-95.0 (n = 44), and > 95.0 (n = 32), respectively. Image quality per-segment was independently assessed by two experienced observers. Image noise and attenuation were also measured. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The effective radiation dose was calculated using CT dose volume index and the dose-length product. A significant correlation was observed between patients' chest circumference and body mass index (r = 0.762, p < 0.001). Chest circumference ranged from 74 to 105 cm, and the mean effective radiation dose was 1.9-3.8 mSv. Diagnostic image quality was obtained in 98.5% (2440/2478) of all evaluated coronary segments without any significant differences among the four groups (p = 0.650). No significant difference in image noise was observed among the four groups (p = 0.439), thus supporting the validity of the chest circumference-adapted scanning protocol. However, vessel attenuation, SNR and CNR were significantly higher in the 100 kV groups than in the 120 kV groups (p < 0.05). A measure of chest circumference can be used to adapt tube voltage and current for individualized radiation dose control, with resultant similar image noise and sustained diagnostic image quality.

  18. Association of Neck Circumference with Obesity in Female College Students.

    Science.gov (United States)

    Papandreou, Dimitrios; Noor, Zujaja Tul; Rashed, Maitha; Jaberi, Hadeel Al

    2015-12-15

    Obesity levels have been dramatically increased in the United Arab Emirates over the last few years. High levels of body Mass Index, waist circumference, and percent of total body fat as a measure of obesity have found to be related to cardiovascular risk factors and other diseases. Neck circumference is a new tool that has been linked to obesity. However, no studies in UAE have been conducted yet. The purpose of this study was to measure the obesity levels in a college population and to correlate them with NC and other anthropometrical indexes. Two hundred forty three (243) female students aged 18-25 were conveniently selected to participate in the study. Anthropometrical indexes were obtained from all subjects e after fasting. The prevalence of overweight and obesity together was found to be 28.4 % (n = 69). Pearson correlation showed that WC, NC and BF (%) were significantly positively related to obesity, (r = 0.790; r = 0.758; r = 0.767, p obesity. NC was found to be independently associated with obesity levels in Emirati college students.

  19. Effect of standard cuff on blood pressure readings in patients with obese arms. How frequent are arms of a 'large circumference'?

    Science.gov (United States)

    Fonseca-Reyes, Salvador; de Alba-García, Javier García; Parra-Carrillo, José Z; Paczka-Zapata, José Antonio

    2003-06-01

    To measure the effect on blood pressure readings when a standard cuff is used on patients with arms of a large circumference, and to determine the frequency of arms of a large circumference. Blood pressures were taken in 120 subjects with an arm circumference greater than 33 cm. Also, the arm circumference was determined in 244 patients from a family health unit, and in 216 patients from a hypertension clinic. A mercury sphygmomanometer and two different cuff sizes were used in a random sequence; therefore, 60 patients' blood pressure were first measured with a large cuff, followed by a standard cuff; the opposite sequence was then applied for another 60 patients. With the obtained values and using a regression analysis, the difference in blood pressure overestimation was calculated. Arm circumference measurement percentages were used to determine the frequency of arms of a large circumference. Both systolic and diastolic blood pressures were significantly greater when the standard cuff was used. For every 5 cm increase in arm circumference, starting at 35 cm, a 2-5 mmHg increase in systolic blood pressure, and a 1-3 mmHg increase in diastolic blood pressure was observed. The prevalence of arms with a large circumference in the family medicine unit and hypertension clinic was 42% and 41.8%, respectively. There is an overestimation of blood pressure when a standard cuff is used in obese subjects. The high prevalence of these individuals in our environment, both in the hypertensive and normotensive population, makes it necessary to have on hand different sizes of cuffs for taking blood pressure in order to avoid incorrect decisions.

  20. Circumference estimation using 3D-whole body scanners and shadow scanner

    NARCIS (Netherlands)

    Daanen, H.A.M.

    1998-01-01

    Clothing designers and manufacturers use traditional body dimensions as their basis. When 3D-whole body scanners are introduced to determine the body dimensions, a conversion has to be made, since scan determined circumference measures are slightly larger than the traditional values. This pilot

  1. Relationship Between Neck Circumference and Epicardial Fat Thickness in a Healthy Male Population.

    Science.gov (United States)

    Küçük, Uğur; Küçük, Hilal Olgun; Cüce, Ferhat; Balta, Sevket

    2016-09-01

    Epicardial fat is an upper body visceral fat depot that may play a significant role in the development of adverse metabolic and cardiovascular risk profiles. There is a significant direct relationship between the amount of epicardial fat and general body adiposity (body mass index, BMI), but data regarding subcutaneous adiposity is limited. We conducted a study to determine the association between neck circumference and epicardial fat thickness in healthy young male individuals, and assess their individual correlations with general body adiposity and cardiometabolic risk factors. One hundred consecutive male patients aged 18 years or older with no known major medical conditions were included in the study. All participants underwent detailed physical examination including measurement of blood pressure, weight, height, waist/hip ratio, and neck circumference. Blood was collected to determine fasting glucose and lipid parameters. A standard echocardiographic examination was performed with additional epicardial fat thickness determination. Among 100 study participants, neck circumference correlated significantly with weight, waist circumference, BMI, blood glucose, serum total cholesterol, low-density (LDL)-cholesterol, and triglycerides levels. No significant correlation was found between neck circumference and high-density lipoprotein (HDL)-cholesterol levels. Neck circumference correlated moderately and positively with echocardiographic epicardial fat thickness. Among patients with low cardiometabolic risk, increased neck circumference was associated with increased epicardial fat thickness. A gordura epicárdica é um depósito de gordura visceral na parte superior do organismo que pode desempenhar um papel importante no desenvolvimento de perfis cardiovasculares e metabólicos adversos. Há uma relação direta significativa entre a quantidade de gordura epicárdica e a adiposidade corporal geral (índice de massa corporal, IMC), mas dados sobre a adiposidade

  2. Dietary energy density in relation to subsequent changes of weight and waist circumference in European men and women.

    Directory of Open Access Journals (Sweden)

    Huaidong Du

    Full Text Available BACKGROUND: Experimental studies show that a reduction in dietary energy density (ED is associated with reduced energy intake and body weight. However, few observational studies have investigated the role of ED on long-term weight and waist circumference change. METHODS AND PRINCIPAL FINDINGS: This population-based prospective cohort study included 89,432 participants from five European countries with mean age 53 years (range: 20-78 years at baseline and were followed for an average of 6.5 years (range: 1.9-12.5 years. Participants were free of cancer, cardiovascular diseases and diabetes at baseline. ED was calculated as the energy intake (kcal from foods divided by the weight (g of foods. Multiple linear regression analyses were performed to investigate the associations of ED with annual weight and waist circumference change. Mean ED was 1.7 kcal/g and differed across study centers. After adjusting for baseline anthropometrics, demographic and lifestyle factors, follow-up duration and energy from beverages, ED was not associated with weight change, but significantly associated with waist circumference change overall. For 1 kcal/g ED, the annual weight change was -42 g/year [95% confidence interval (CI: -112, 28] and annual waist circumference change was 0.09 cm/year [95% CI: 0.01, 0.18]. In participants with baseline BMI<25 kg/m(2, 1 kcal/g ED was associated with a waist circumference change of 0.17 cm/year [95% CI: 0.09, 0.25]. CONCLUSION: Our results suggest that lower ED diets do not prevent weight gain but have a weak yet potentially beneficial effect on the prevention of abdominal obesity as measured by waist circumference.

  3. Prostate carcinoma (PC) - an organ-related specific pathological neoplasm; Prostatakarzinom (PC) - eine organspezifische Neoplasie aus der Sicht der Pathologie

    Energy Technology Data Exchange (ETDEWEB)

    Massmann, J.; Funk, A. [Gemeinschaftspraxis Pathologie Massmann-Funk-Dettmar, Muenchen (Germany); Altwein, J. [Krankenhaus der Barmherzigen Brueder, Muenchen (Germany); Praetorius, M.

    2003-06-01

    The organ- and tumour-related specific characteristics of prostate carcinoma (PC) are presented in an overview under various aspects. It is the key for understanding pathological changes, including PC, to consider the subdivision of the prostate into anatomically and functionally distinguishable zones, especially the transitional zone (TZ) and the peripheral zone (PZ). The pseudoneoplastic hyperplasia of the TZ, combined with inflammatory consequences and age-related changes, forms a differential diagnostic challenge to both clinico-radiological diagnosis and macroscopic and microscopic examination. High-degree prostatic intra-epithelial neoplasia (PIN III) and atypical adenomatous hyperplasia (AAH) are presented as precursor lesions of PC with varying significance and assessment. Moreover, there are discussed the following characteristic features of PC: localisation types, focality, volume, progression, double-graduation according to Gleason, tumour stage, and prognosis. The most important prognosis factors of PC (category I) include the categories of the TNM system, such as stage, surgical marginal situation, degree and also the preoperative PSA level as a (poor) substitute for the tumour volume. Potential prognosis parameters (category II) show the tumour volume and the DNS ploidy, while there continues to exist a large number of non-established parameters (category III). The prognostic validity of the pathological examinations depends, on the one hand, on the tissue extent (needle biopsy, transurethral resection (TURP), so-called simple prostatectomy, radical prostatectomy (RPE)) and the prostate zones covered. On the other hand, the prognostic certainty also depends on the tumour-adequate macroscopic and microscopic assessment of an RPE that can only be a partial or complete handling in transversal large-area sections. (orig.) [German] Die organ- und tumorspezifischen Besonderheiten des Prostatakarzinoms (PC) werden in einer Uebersicht unter verschiedenen

  4. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study

    Science.gov (United States)

    West, Jane; Manchester, Ben; Wright, John; Lawlor, Debbie A; Waiblinger, Dagmar

    2011-01-01

    Summary West J, Manchester B, Wright J, Lawlor DA, Waiblinger D. Reliability of routine clinical measurements of neonatal circumferences and research measurements of neonatal skinfold thicknesses: findings from the Born in Bradford study. Paediatric and Perinatal Epidemiology 2011. Assessing neonatal size reliably is important for research and clinical practice. The aim of this study was to examine the reliability of routine clinical measurements of neonatal circumferences and of skinfold thicknesses assessed for research purposes. All measurements were undertaken on the same population of neonates born in a large maternity unit in Bradford, UK. Technical error of measurement (TEM), relative TEM and the coefficient of reliability are reported. Intra-observer TEMs for routine circumference measurements were all below 0.4 cm and were generally within ±2-times the mean. Inter-observer TEM ranged from 0.20 to 0.36 cm for head circumference, 0.19 to 0.39 cm for mid upper arm circumference and from 0.39 to 0.77 cm for abdominal circumference. Intra and inter-observer TEM for triceps skinfold thickness ranged from 0.22 to 0.35 mm and 0.15 to 0.54 mm, respectively. Subscapular skinfold thickness TEM values were 0.14 to 0.25 mm for intra-observer measurements and 0.17 to 0.63 mm for inter-observer measurements. Relative TEM values for routine circumferences were all below 4.00% but varied between 2.88% and 14.23% for research skinfold measurements. Reliability was mostly between 80% and 99% for routine circumference measurements and ≥70% for most research skinfold measurements. Routine clinical measurements of neonatal circumferences are reliably assessed in Bradford. Assessing skinfolds in neonates has variable reliability, but on the whole is good. The greater intra-observer, compared with inter-observer, reliability for both sets of measurements highlights the importance of having a minimal number of assessors whenever possible. PMID:21281329

  5. Investigasi Serangan Malware Njrat Pada PC

    Directory of Open Access Journals (Sweden)

    Devi Rizky Septiani

    2016-12-01

    Full Text Available Malware merupakan salah satu bentuk dari kejahatan komputer yang terjadi pada sebuah sistem jaringan komputer, malware Njrat termasuk jenis Trojan horse. Trojan adalah salah satu jenis malware yang ikut berkembang di dalamnya, yang memungkinkan attacker masuk ke dalam sistem tanpa diketahui oleh pemilik. Penggunaan trojan saat ini lebih ke arah kejahatan dunia maya (cyber crime, salah satu dari malware yang sangat berbahaya karena besarnya dampak kerugian yang ditimbulkan, mulai dari pencurian data penting sampai mengubah hak akses pada PC korban. Sasaran terbanyak penybaran trojan adalah pengguna sistem operasi windows. Penyebaran trojan ini dilakukan dengan metode social engineering, yaitu teknik yang menggunakan kelemahan manusia, sehingga user tanpa curiga langsung mengeksekusi sebuah program yang tidak dikenal.  Aktivitas malware berkaitan erat dengan  performa PC dan juga aktifitas network pada system computer. Penelitian ini bertujuan untuk mengetahui cara kerja malware Njrat dan melakukan investigasi terhadap performa pada system computer. Metodologi yang digunakan dynamic analysis dengan melakukan analisa malware pada suatu sistem dan melihat aktivitas atau proses yang diaktifkan oleh malware tersebut. Dampak perubahan yang terjadi pada PC Target terlihat pada performa masing-masing PC yang telah disisipkan malware. Kata kunci            Malware, Njrat, System computer

  6. Multi-satellite study of the excitation of Pc3 and Pc4-5 ULF waves and their penetration across the plasmapause during the 2003 Halloween superstorm

    Science.gov (United States)

    Balasis, G.; Daglis, I. A.; Mann, I. R.; Papadimitriou, C.; Zesta, E.; Georgiou, M.; Haagmans, R.; Tsinganos, K.

    2015-10-01

    We use multi-satellite and ground-based magnetic data to investigate the concurrent characteristics of Pc3 (22-100 mHz) and Pc4-5 (1-22 mHz) ultra-low-frequency (ULF) waves on the 31 October 2003 during the Halloween magnetic superstorm. ULF waves are seen in the Earth's magnetosphere, topside ionosphere, and Earth's surface, enabling an examination of their propagation characteristics. We employ a time-frequency analysis technique and examine data from when the Cluster and CHAMP spacecraft were in good local time (LT) conjunction near the dayside noon-midnight meridian. We find clear evidence of the excitation of both Pc3 and Pc4-5 waves, but more significantly we find a clear separation in the L shell of occurrence of the Pc4-5 and Pc3 waves in the equatorial inner magnetosphere, separated by the density gradients at the plasmapause boundary layer. A key finding of the wavelet spectral analysis of data collected from the Geotail, Cluster, and CHAMP spacecraft and the CARISMA and GIMA magnetometer networks was a remarkably clear transition of the waves' frequency into dominance in a higher-frequency regime within the Pc3 range. Analysis of the local field line resonance frequency suggests that the separation of the Pc4-5 and Pc3 emissions across the plasmapause is consistent with the structure of the inhomogeneous field line resonance Alfvén continuum. The Pc4-5 waves are consistent with direct excitation by the solar wind in the plasma trough, as well as Pc3 wave absorption in the plasmasphere following excitation by upstream waves originating at the bow shock in the local noon sector. However, despite good solar wind coverage, our study was not able to unambiguously identify a clear explanation for the sharp universal time (UT) onset of the discrete frequency and large-amplitude Pc3 wave power.

  7. Neck Circumference as a Predictive Indicator of CKD for High Cardiovascular Risk Patients

    Directory of Open Access Journals (Sweden)

    Ya-Fang Liu

    2015-01-01

    Full Text Available Background. Neck circumference (NC is an anthropometric measure of obesity for upper subcutaneous adipose tissue distribution which is associated with cardiometabolic risk. This study investigated whether NC is associated with indicators of chronic kidney disease (CKD for high cardiometabolic risk patients. Methods. A total of 177 consecutive patients who underwent the outpatient departments of cardiology were prospectively enrolled in the study. The patients were aged >20 years with normal renal function or with stages 1–4 CKD. A linear regression was performed using the Enter method to present an unadjusted R2, standardized coefficients, and standard error, and the Durbin-Watson test was used to assess residual independence. Results. Most anthropometric measurements from patients aged ≧65 were lower than those from patients aged <65, except for women’s waist circumference (WC and waist hip ratio. Female NC obtained the highest R2 values for 24 hr CCR, uric acid, microalbuminuria, hsCRP, triglycerides, and HDL compared to BMI, WC, and hip circumference. The significances of female NC with 24 hr CCR and uric acid were improved after adjusted age and serum creatinine. Conclusions. NC is associated with indicators of CKD for high cardiometabolic risk patients and can be routinely measured as easy as WC in the future.

  8. Port virtual addressing for PC

    International Nuclear Information System (INIS)

    Bolanos, L.; Arista, E.; Osorio Deliz, J.F.

    1997-01-01

    Instruments for nuclear signal measurements based on add-on card for a personal computer (PC) are designed often. Then one faces the problem of the addressing of data input/output devices which show an integration level or intelligence that makes the use of several port address indispensable, and these are limited in the PC. The virtual addressing offers the advantage of the occupation of few addresses to accede to many of these devices. The principles of this technique and the appliances of a solution in radiometric in a radiometric card based on programmed logic are discussed in this paper

  9. PC based 8K multichannel analyser for nuclear spectroscopy

    International Nuclear Information System (INIS)

    Jain, S.K.; Gupta, J.D.; Suman Kumari, B.

    1989-01-01

    An IBM-PC based 8K multichannel analyser(MCA) has been developed which incorporates all the features of an advanced system like very high throughput for data acquisition in PHA as well as MCS modes, fast real-time display, extensive display manipulation facilities, various present controls and concurrent data processing. The compact system hardware consists of a 2 bit wide NIM module and a PC add-on card. Because of external acquisition hardware, the system after initial programming by PC can acquire data independently allowing the PC to be switched off. To attain very high throughput, the most desirable feature of an MCA, a dual-port memory architecture has been used. The asymmetric dual-port RAM, housed in the NIM module offers 24 bit parallel access to the ADC and 8 bit wide access to PC which results in fast real-time histogramic display on the monitor. PC emulation software is menu driven and user friendly. It integrates a comprehensive set of commonly required application routines for concurrent data processing. After the transfer of know-how to the Electronic Corporation of India Ltd. (ECIL), this system is bein g produced at ECIL. (author). 5 refs., 4 figs

  10. Early childhood television viewing predicts explosive leg strength and waist circumference by middle childhood.

    Science.gov (United States)

    Fitzpatrick, Caroline; Pagani, Linda S; Barnett, Tracie A

    2012-07-16

    The relationship between early childhood television viewing and physical fitness in school age children has not been extensively studied using objective outcome measures. Using a sample of 1314 children from the Québec Longitudinal Study of Child Development, we examine the association between parental reports of weekly hours of television viewing, assessed at 29 and 53 months of age, and direct measures of second grade muscular fitness using performances on the standing long jump test (SLJ) and fourth grade waist circumference. Controlling for many potentially confounding child and family variables, each hour per week of television watched at 29 months corresponded to a .361 cm decrease in SLJ, 95% CI between -.576 and -.145. A one hour increase in average weekly television exposure from 29 to 53 months was associated with a further .285 cm reduction in SLJ test performance, 95% CI between -.436 and -.134 cm and corresponded to a .047 cm increase in waistline circumference, 95% CI between .001 and .094 cm. Watching television excessively in early childhood, may eventually compromise muscular fitness and waist circumference in children as they approach pubertal age.

  11. Early childhood television viewing predicts explosive leg strength and waist circumference by middle childhood

    Directory of Open Access Journals (Sweden)

    Fitzpatrick Caroline

    2012-07-01

    Full Text Available Abstract Background The relationship between early childhood television viewing and physical fitness in school age children has not been extensively studied using objective outcome measures. Methods Using a sample of 1314 children from the Québec Longitudinal Study of Child Development, we examine the association between parental reports of weekly hours of television viewing, assessed at 29 and 53 months of age, and direct measures of second grade muscular fitness using performances on the standing long jump test (SLJ and fourth grade waist circumference. Results Controlling for many potentially confounding child and family variables, each hour per week of television watched at 29 months corresponded to a .361 cm decrease in SLJ, 95% CI between -.576 and -.145. A one hour increase in average weekly television exposure from 29 to 53 months was associated with a further .285 cm reduction in SLJ test performance, 95% CI between -.436 and -.134 cm and corresponded to a .047 cm increase in waistline circumference, 95% CI between .001 and .094 cm. Interpretation Watching television excessively in early childhood, may eventually compromise muscular fitness and waist circumference in children as they approach pubertal age.

  12. Assessing factors related to waist circumference and obesity: application of a latent variable model.

    Science.gov (United States)

    Dalvand, Sahar; Koohpayehzadeh, Jalil; Karimlou, Masoud; Asgari, Fereshteh; Rafei, Ali; Seifi, Behjat; Niksima, Seyed Hassan; Bakhshi, Enayatollah

    2015-01-01

    Because the use of BMI (Body Mass Index) alone as a measure of adiposity has been criticized, in the present study our aim was to fit a latent variable model to simultaneously examine the factors that affect waist circumference (continuous outcome) and obesity (binary outcome) among Iranian adults. Data included 18,990 Iranian individuals aged 20-65 years that are derived from the third National Survey of Noncommunicable Diseases Risk Factors in Iran. Using latent variable model, we estimated the relation of two correlated responses (waist circumference and obesity) with independent variables including age, gender, PR (Place of Residence), PA (physical activity), smoking status, SBP (Systolic Blood Pressure), DBP (Diastolic Blood Pressure), CHOL (cholesterol), FBG (Fasting Blood Glucose), diabetes, and FHD (family history of diabetes). All variables were related to both obesity and waist circumference (WC). Older age, female sex, being an urban resident, physical inactivity, nonsmoking, hypertension, hypercholesterolemia, hyperglycemia, diabetes, and having family history of diabetes were significant risk factors that increased WC and obesity. Findings from this study of Iranian adult settings offer more insights into factors associated with high WC and high prevalence of obesity in this population.

  13. Assessing Factors Related to Waist Circumference and Obesity: Application of a Latent Variable Model

    Directory of Open Access Journals (Sweden)

    Sahar Dalvand

    2015-01-01

    Full Text Available Background. Because the use of BMI (Body Mass Index alone as a measure of adiposity has been criticized, in the present study our aim was to fit a latent variable model to simultaneously examine the factors that affect waist circumference (continuous outcome and obesity (binary outcome among Iranian adults. Methods. Data included 18,990 Iranian individuals aged 20–65 years that are derived from the third National Survey of Noncommunicable Diseases Risk Factors in Iran. Using latent variable model, we estimated the relation of two correlated responses (waist circumference and obesity with independent variables including age, gender, PR (Place of Residence, PA (physical activity, smoking status, SBP (Systolic Blood Pressure, DBP (Diastolic Blood Pressure, CHOL (cholesterol, FBG (Fasting Blood Glucose, diabetes, and FHD (family history of diabetes. Results. All variables were related to both obesity and waist circumference (WC. Older age, female sex, being an urban resident, physical inactivity, nonsmoking, hypertension, hypercholesterolemia, hyperglycemia, diabetes, and having family history of diabetes were significant risk factors that increased WC and obesity. Conclusions. Findings from this study of Iranian adult settings offer more insights into factors associated with high WC and high prevalence of obesity in this population.

  14. Relationships between neonatal weight, limb lengths, skinfold thicknesses, body breadths and circumferences in an Australian cohort.

    Directory of Open Access Journals (Sweden)

    Emma Pomeroy

    Full Text Available Low birth weight has been consistently associated with adult chronic disease risk. The thrifty phenotype hypothesis assumes that reduced fetal growth impacts some organs more than others. However, it remains unclear how birth weight relates to different body components, such as circumferences, adiposity, body segment lengths and limb proportions. We hypothesized that these components vary in their relationship to birth weight.We analysed the relationship between birth weight and detailed anthropometry in 1270 singleton live-born neonates (668 male from the Mater-University of Queensland Study of Pregnancy (Brisbane, Australia. We tested adjusted anthropometry for correlations with birth weight. We then performed stepwise multiple regression on birth weight of: body lengths, breadths and circumferences; relative limb to neck-rump proportions; or skinfold thicknesses. All analyses were adjusted for sex and gestational age, and used logged data.Circumferences, especially chest, were most strongly related to birth weight, while segment lengths (neck-rump, thigh, upper arm, and especially lower arm and lower leg were relatively weakly related to birth weight, and limb lengths relative to neck-rump length showed no relationship. Skinfolds accounted for 36% of birth weight variance, but adjusting for size (neck-rump, thigh and upper arm lengths, and head circumference, this decreased to 10%. There was no evidence that heavier babies had proportionally thicker skinfolds.Neonatal body measurements vary in their association with birth weight: head and chest circumferences showed the strongest associations while limb segment lengths did not relate strongly to birth weight. After adjusting for body size, subcutaneous fatness accounted for a smaller proportion of birth weight variance than previously reported. While heavier babies had absolutely thicker skinfolds, this was proportional to their size. Relative limb to trunk length was unrelated to birth

  15. Physical and Mechanical Characteristics of Kevlar Fiber-Reinforced PC/ABS Composites

    Directory of Open Access Journals (Sweden)

    Kuljira Sujirote

    2012-01-01

    Full Text Available In this research, the composites between polycarbonate (PC and acrylonitrile-butadiene-styrene (ABS alloy and Kevlar fiber were prepared. The flexural and tensile properties of PC/ABS alloy and its composites were determined using a universal testing machine. The synergistic behavior of flexural modulus was observed for all regions of PC contents, while the synergism of flexural strength and tensile strength were found in some PC contents. It was found that the optimum weight ratio of PC:ABS was 60:40. In the Kevlar Fiber-reinforced PC/ABS composite system at PC:ABS of 60:40, both flexural modulus and strength were increased with matrix contents. Additionally, the flexural strength drastically increased with the matrix content and then reached the maximum value of 167 MPa at the matrix content of 33.4 wt%. The results from peel test, water contact measurement, and scanning electron microscopy (SEM reveal that the interfacial adhesion between the Kevlar fiber and the polymer matrix could be improved by increasing the PC content in the matrix.

  16. Neck circumference as a new anthropometric indicator for prediction of insulin resistance and components of metabolic syndrome in adolescents: Brazilian Metabolic Syndrome Study

    Directory of Open Access Journals (Sweden)

    Cleliani de Cassia da Silva

    2014-06-01

    Full Text Available OBJECTIVE: To evaluate the correlation between neck circumference and insulin resistance and components of metabolic syndrome in adolescents with different adiposity levels and pubertal stages, as well as to determine the usefulness of neck circumference to predict insulin resistance in adolescents.METHODS:Cross-sectional study with 388 adolescents of both genders from ten to 19 years old. The adolescents underwent anthropometric and body composition assessment, including neck and waist circumferences, and biochemical evaluation. The pubertal stage was obtained by self-assessment, and the blood pressure, by auscultation. Insulin resistance was evaluated by the Homeostasis Model Assessment-Insulin Resistance. The correlation between two variables was evaluated by partial correlation coefficient adjusted for the percentage of body fat and pubertal stage. The performance of neck circumference to identify insulin resistance was tested by Receiver Operating Characteristic Curve.RESULTS: After the adjustment for percentage body fat and pubertal stage, neck circumference correlated with waist circumference, blood pressure, triglycerides and markers of insulin resistance in both genders.CONCLUSIONS: The results showed that the neck circumference is a useful tool for the detection of insulin resistance and changes in the indicators of metabolic syndrome in adolescents. The easiness of application and low cost of this measure may allow its use in Public Health services.

  17. Design of multichannel counting system for IBM PC and compatibles

    International Nuclear Information System (INIS)

    Majeed, B.; Ahmad, Z.; Osman, A.; Ysain, M.M.

    1995-07-01

    A Multichannel Counting System (MCCS), based on IBM-PC and compatible computer systems have been designed. The MCCS consists of a Multichannel Counting System plug-in interface card (MCCS-PC) for IBM PC and compatibles and a NIM-BIN module (MCCS-NB). The MCCS-PC provides simultaneous monitoring of upto seven independent SCA type inputs. An on board programmable timer provides elapsed time measurement. A menu-driven program for data acquisition and timer control has also been developed. (author) 8 figs

  18. Multi-satellite study of the excitation of Pc3 and Pc4-5 ULF waves and their penetration across the plasmapause during the 2003 Halloween superstorm

    Directory of Open Access Journals (Sweden)

    G. Balasis

    2015-10-01

    Full Text Available We use multi-satellite and ground-based magnetic data to investigate the concurrent characteristics of Pc3 (22–100 mHz and Pc4-5 (1–22 mHz ultra-low-frequency (ULF waves on the 31 October 2003 during the Halloween magnetic superstorm. ULF waves are seen in the Earth's magnetosphere, topside ionosphere, and Earth's surface, enabling an examination of their propagation characteristics. We employ a time–frequency analysis technique and examine data from when the Cluster and CHAMP spacecraft were in good local time (LT conjunction near the dayside noon–midnight meridian. We find clear evidence of the excitation of both Pc3 and Pc4-5 waves, but more significantly we find a clear separation in the L shell of occurrence of the Pc4-5 and Pc3 waves in the equatorial inner magnetosphere, separated by the density gradients at the plasmapause boundary layer. A key finding of the wavelet spectral analysis of data collected from the Geotail, Cluster, and CHAMP spacecraft and the CARISMA and GIMA magnetometer networks was a remarkably clear transition of the waves' frequency into dominance in a higher-frequency regime within the Pc3 range. Analysis of the local field line resonance frequency suggests that the separation of the Pc4-5 and Pc3 emissions across the plasmapause is consistent with the structure of the inhomogeneous field line resonance Alfvén continuum. The Pc4-5 waves are consistent with direct excitation by the solar wind in the plasma trough, as well as Pc3 wave absorption in the plasmasphere following excitation by upstream waves originating at the bow shock in the local noon sector. However, despite good solar wind coverage, our study was not able to unambiguously identify a clear explanation for the sharp universal time (UT onset of the discrete frequency and large-amplitude Pc3 wave power.

  19. Comparison of Marginal Circumference of Two Different Pre-crimped Stainless Steel Crowns for Primary Molars After Re-crimping

    Directory of Open Access Journals (Sweden)

    Hossein Afshar

    2016-08-01

    Full Text Available Objectives: It is not clear what type of pre-crimped crown is more successful in achieving greater marginal adaptation following re-crimping. This study aimed to assess the changes in the circumference of 3M ESPE and MIB pre-crimped stainless steel crowns (SSCs for the primary maxillary and mandibular first and second molars following re-crimping.Materials and Methods: This was an in-vitro, experimental study. Initial photographs were obtained from the margins of 3M and MIB SSCs for the upper and lower primary molars using a digital camera. Crown margins were crimped by applying 0.2N force using 114 and 137 pliers. Post-crimping photographs were also obtained and the changes in crown circumference after crimping were calculated using AutoCad software. The percentage of reduction in the circumference of crowns for each tooth was statistically analyzed based on the type of crown using student t-test. The effect of crown design and the associated teeth on the decreased circumference percentage was statistically analyzed by two-sided ANOVA.Results: The percentage of reduction in lower E SSC circumference was 3.71±0.39% in MIB and 6.29±0.62% in 3M crowns. These values were 3.55±0.55% and 7.15±1.13% for the lower Ds, and 3.95±0.43 and 6.24±0.85% for the upper Ds, respectively. For the upper Es, these values were found to be 3.12±0.65% and 5.14±0.94%, respectively. For each tooth, a significant difference was found between MIB and 3M SSCs in terms of the percentage of reduction in crown circumference following crimping. The magnitude of this reduction was smaller in MIB compared to 3M SSCs (P<0.001.Conclusion: Considering the significant reduction in the marginal circumference of pre-crimped SSCs following re-crimping, it appears that this manipulation must be necessarily performed for MIB and 3M pre-crimped SSCs. By using 3M SSCs, higher marginal adaptation can be achieved following crimping.

  20. Chest circumference and birth weight are good predictors of lung function in preschool children from an e-waste recycling area.

    Science.gov (United States)

    Zeng, Xiang; Xu, Xijin; Zhang, Yuling; Li, Weiqiu; Huo, Xia

    2017-10-01

    The purpose of this study was to investigate the associations between birth weight, chest circumference, and lung function in preschool children from e-waste exposure area. A total of 206 preschool children from Guiyu (an e-waste recycling area) and Haojiang and Xiashan (the reference areas) in China were recruited and required to undergo physical examination, blood tests, and lung function tests during the study period. Birth outcome such as birth weight and birth height were obtained by questionnaire. Children living in the e-waste-exposed area have a lower birth weight, chest circumference, height, and lung function when compare to their peers from the reference areas (all p value <0.05). Both Spearman and partial correlation analyses showed that birth weight and chest circumference were positively correlated with lung function levels including forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV 1 ). After adjustment for the potential confounders in further linear regression analyses, birth weight, and chest circumference were positively associated with lung function levels, respectively. Taken together, birth weight and chest circumference may be good predictors for lung function levels in preschool children.

  1. El blindaje de una PC

    Directory of Open Access Journals (Sweden)

    Revista Chasqui

    2015-01-01

    Full Text Available La navegación en Internet y la consiguiente conexión a una red expone a una computadora a un sinfín de riesgos y peligros. Una PC que no sea utilizada para navegar en Internet o que no esté conectada a una red puede,incluso, ser también afectada por virus, por la utilización de disquetes contaminados que la contaminen con un virus. Para enfrentar esos problemas, la industria informática ha previsto una serie de protecciones y recaudos, de cuyo uso y utilización deben estar plenamente informados los usuarios de una PC.

  2. Predicting waist circumference from body mass index.

    Science.gov (United States)

    Bozeman, Samuel R; Hoaglin, David C; Burton, Tanya M; Pashos, Chris L; Ben-Joseph, Rami H; Hollenbeak, Christopher S

    2012-08-03

    Being overweight or obese increases risk for cardiometabolic disorders. Although both body mass index (BMI) and waist circumference (WC) measure the level of overweight and obesity, WC may be more important because of its closer relationship to total body fat. Because WC is typically not assessed in clinical practice, this study sought to develop and verify a model to predict WC from BMI and demographic data, and to use the predicted WC to assess cardiometabolic risk. Data were obtained from the Third National Health and Nutrition Examination Survey (NHANES) and the Atherosclerosis Risk in Communities Study (ARIC). We developed linear regression models for men and women using NHANES data, fitting waist circumference as a function of BMI. For validation, those regressions were applied to ARIC data, assigning a predicted WC to each individual. We used the predicted WC to assess abdominal obesity and cardiometabolic risk. The model correctly classified 88.4% of NHANES subjects with respect to abdominal obesity. Median differences between actual and predicted WC were -0.07 cm for men and 0.11 cm for women. In ARIC, the model closely estimated the observed WC (median difference: -0.34 cm for men, +3.94 cm for women), correctly classifying 86.1% of ARIC subjects with respect to abdominal obesity and 91.5% to 99.5% as to cardiometabolic risk.The model is generalizable to Caucasian and African-American adult populations because it was constructed from data on a large, population-based sample of men and women in the United States, and then validated in a population with a larger representation of African-Americans. The model accurately estimates WC and identifies cardiometabolic risk. It should be useful for health care practitioners and public health officials who wish to identify individuals and populations at risk for cardiometabolic disease when WC data are unavailable.

  3. Thigh and knee circumference, knee-extension strength, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten Tange; Husted, Henrik

    2011-01-01

    OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective, descrip......OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective......, descriptive, hypothesis-generating study. SETTING: A special unit for fast-track hip and knee arthroplasty operations at a university hospital. PARTICIPANTS: Twenty-four patients (20 women and 4 men; ages 69 ± 6.1 years) scheduled for primary unilateral THA. METHODS: All patients were evaluated before surgery......, except for hip pain. The average loss in knee-extension strength after surgery (32%, P = .01) did not correlate with increased thigh circumference (6%, P

  4. Application of simplified PC-SAFT to glycol ethers

    DEFF Research Database (Denmark)

    Avlund, Ane Søgaard; Kontogeorgis, Georgios; Michelsen, Michael Locht

    2012-01-01

    The simplified PC-SAFT (sPC-SAFT) equation of state is applied for binary glycol ether-containing mixtures, and it is investigated how the results are influenced by inclusion of intramolecular association in the association theory. Three different glycol ethers are examined: 2-methoxyethanol, 2...

  5. PC Farms for Offline Event Reconstruction at Fermilab

    International Nuclear Information System (INIS)

    Beretvas, A.

    1997-03-01

    Fermilab is investigating the use of PC's for HEP computing. As a first step we have built a full offline environment under Linux on a set of Pentium (P5) and Pentium Pro (P6) machines (the ''PC Farm''). The Pythia simulation has been ported to run serially and in parallel (using CPS) on the PC Farm. Fermilab software products and CDF offline packages have also been ported to Linux. Run 1 CDF data has been analyzed on both Linux and SGI (Irix) with essentially identical results. The performance of the system is compared to results with commercial UNIX systems

  6. Test of radiation hardness of pcCVD detectors

    Energy Technology Data Exchange (ETDEWEB)

    Schlemme, Steffen [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Technische Universitaet Darmstadt (Germany); Enders, Joachim [Technische Universitaet Darmstadt (Germany); Figuera, P.; Salamone, S. [LNS-INFN Catania (Italy); Fruehauf, J.; Kis, Mladen; Kratz, A.; Kurz, N.; Loechner, S.; Nociforo, Chiara; Schirru, Fabio; Szczepanczyk, B.; Traeger, M.; Visinka, R. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Musumarra, A. [LNS-INFN Catania (Italy); University of Catania (Italy)

    2016-07-01

    The new in-flight separator Super-FRS is under construction at the Facility for Antiproton and Ion Research (FAIR, Darmstadt). Ion rates up to 3 x 10{sup 11} {sup 238}U/spill demand an adaption of detectors to a high radiation environment. A test experiment to investigate the radiation hardness of polycrystalline diamond detectors (pcCVD) was performed at the LNS-INFN in Catania using a {sup 12}C beam at 62 MeV/u and intensities of up to 1.5 pnA. The setup consisted of pcCVD strip detectors to measure the beam profile, a single crystal diamond detector to calibrate the ionisation chamber working in current mode as a beam intensity monitor and a pcCVD sample to be irradiated. The IC used was designed for FAIR and showed a stable counting rate allowing us to calibrate and perform beam intensity measurements with it. The total measured counts on the sample were 8.25 x 10{sup 11} counts/mm{sup 2} over a period of 60 hours. Digital waveforms of the pcCVD signals were taken with an oscilloscope and analysed. The results showed no change of the pcCVD signal properties during the entire irradiation.

  7. Preoperative measurement of maternal abdominal circumference relates the initial sensory block level of spinal anesthesia for cesarean section: An observational study

    Directory of Open Access Journals (Sweden)

    Chi-Hang Kuok

    2016-12-01

    Conclusion: Parturients with greater abdominal circumference value have a higher level of sensory blockade at 5 minutes after spinal anesthesia. Abdominal circumference cannot predict the maximum sensory blockade level and the incidence of hypotension.

  8. Neck circumference as a screening measure of overweight/obesity among Indian adults

    Directory of Open Access Journals (Sweden)

    Mondal Nitish

    2016-09-01

    Full Text Available Neck circumference (NC is an anthropometric measurement of differentiating body fat distributions and a marker of upper subcutaneous adiposity. The present study highlights the association and importance of NC as a suitable proxy screening measure of overweight/obesity as compared to the conventional anthropometric variables used among Indian adults. The present community based cross-sectional study was undertaken among 1169 Karbi adults (males: 625; females: 544 residing in Karbi Anglong district of Assam, Northeast India, who were selected through a multistage stratified random sampling method. Height, weight, waist circumference (WC, hip circumference (HC and NC were recorded using standard procedures. The body mass index (BMI was calculated and prevalence of overweight/obesity was assessed using standard cut-offs. The prevalence of obesity using BMI (≥25.00 kg m-2 was 15.52% and 15.26% among males and females, respectively (p≥0.05.The prevalence of obesity using NC was observed to be significantly higher among males (48.80% than females (19.12% (p<0.01. The binary logistic regression analysis showed that NC predicted obesity over the conventional anthropometric variables with reasonable accuracy (p<0.01. The ROC-AUC analysis showed a relatively greater significant association between BMI, WC and HC and NC for obesity (p<0.01. Thus, NC appears to be a potentially simple, easyto- use screening measure for predicting obesity among adults. Further studies are required to validate its use for screening of obesity among other ethnic populations in India.

  9. Nutritional profile of the elderly - Relationship obesity and waist circumference sixty years after

    Directory of Open Access Journals (Sweden)

    Ramara Kadija Fonseca Santos

    2014-05-01

    Full Text Available In the aging process the metabolic changes can cause changes in health, including nutritional status, making the absorption of nutrients or promoting the accumulation of adipose tissue. Given this, this study aimed to assess the nutritional status of the participants in an open design for the elderly, through documentary analysis of values of Body Mass Index (BMI and Waist Circumference (WC. The analyzed results show a relationship between aging and the accumulation of visceral fat, since individuals considered eutrophic demonstrated a strong CC, as the data below, in which 11.53% of the data showed that subjects with low birth weight, 42,32 % normal weight, overweight and 46.5%, comparing with 80.76% of the values with large waist circumference, increasing the risk of developing some type of metabolic disease.

  10. NUTRITIONAL PROFILE OF THE ELDERLY - RELATIONSHIP OBESITY AND WAIST CIRCUMFERENCE SIXTY YEARS AFTER

    Directory of Open Access Journals (Sweden)

    Ramara Kadija Fonseca Santos

    2014-08-01

    Full Text Available In the aging process the metabolic changes can cause changes in health, including nutritional status, making the absorption of nutrients or promoting the accumulation of adipose tissue. Given this, this study aimed to assess the nutritional status of the participants in an open design for the elderly, through documentary analysis of values of Body Mass Index (BMI and Waist Circumference (WC. The analyzed results show a relationship between aging and the accumulation of visceral fat, since individuals considered eutrophic demonstrated a strong CC, as the data below, in which 11.53% of the data showed that subjects with low birth weight, 42,32 % normal weight, overweight and 46.5%, comparing with 80.76% of the values with large waist circumference, increasing the risk of developing some type of metabolic disease.

  11. PC data station for Hitachi F-2000 spectrofluorimeter

    International Nuclear Information System (INIS)

    Yakub Ali, Mohd; Dhoble, A.R.; Jadhav, R.T.; Godbole, S.V.

    2004-01-01

    The paper describes the PC based data station for stand-alone HIT ACHI F-2000 Spectrofluorimeter, for data acquisition, storage and analysis. The hardware link between the instrument and PC is made through RS232 serial port. The state of art software for control and data management is designed, developed and implemented in Visual Basic (Version 6). The software features on-screen editing of all operation parameters of the instrument and the operational control is achieved by Visual Basic command words communicated through serial port. Using this system, in addition to acquiring and storage of spectral data, it was possible to obtain the normalized absorption spectra of the samples. PC adapted Hitachi F-2000 Spectrofluorimeter can be successfully used for various operations such as photometric detection of UO22+ ions, recording of emission and excitation spectra and time evolution of fluorescence intensity on continuous UV irradiation. The data storage achieved through PC adaptation has also enabled recording of absorption spectra. (author)

  12. Significance of periacinar cleftings as supporting criteria in diagnosis of prostatic adenocarcinoma Gleason score-a 7 (3+4 and Gleason score-a 7 (4+3 and their relationship with parameters of predictive value

    Directory of Open Access Journals (Sweden)

    Mijović Milica

    2014-01-01

    Full Text Available Diagnosis of different pathohystological diseases of prostate in the most cases is based on common benignant and malignant characteristics. The presence of periacinar cleftings (PC is an additional criterion favouring prostatic adenocarcinoma. According to the presence and extent of PC, analysed on high power field (400x, glands were classified into 3 groups: group 1-glands without PC or with PC affecting ≤50% of gland circumference; group 2-glands with PC affecting >50% gland circumference in 50% gland circumference in ≥50% examined glands. The aim of our study was to determine the importance of presence of PC in prostatic adenocarcinoma (ADCP of Gleason score 7(3+4 and 7(4+3 and establish the existence of differences in their appearance at ADCP with first and second dominant histological grade 3 and 4 in each different relationship based on correlation analysis of PC and parameters of the predictive value (preoperative value of serum prostate specific antigen, tumor volume, clinical stage and degree of focal neuroendocrine differentiation. The study included 33 ADCP of Gleason score 7, 26 (78.79% ADCP 7(3+4 and 7 (21.21% ADCP 7(4+3. In ADCP Gleason 7(3+4 periacinar cleftings are more common in tumors that are smaller, better differentiated (produce more PSA, which is diagnosed in less advanced clinical stages and showing a less degree of focal neuroendocrine differentiation. In ADCP Gleason 7(4+3 periacinar cleftings are more common in tumors which produce less value of serum PSA (poorly differentiated and in tumors that are diagnosed in advanced clinical stages. Periacinar cleftings are common findings in prostatic adenocarcinoma Gleason score 7(4+3 which are considerd as tumors with worse prognosis. Because of all we can rank PC among the important additional criteria for the diagnosis of adenocarcinoma of the prostate.

  13. The effect of height, weight and head circumference on gross motor development in achondroplasia.

    Science.gov (United States)

    Ireland, Penelope Jane; Ware, Robert S; Donaghey, Samantha; McGill, James; Zankl, Andreas; Pacey, Verity; Ault, Jenny; Savarirayan, Ravi; Sillence, David; Thompson, Elizabeth; Townshend, Sharron; Johnston, Leanne M

    2013-02-01

    This study aimed to investigate whether height, weight, head circumference and/or relationships between these factors are associated with gross motor milestone acquisition in children with achondroplasia. Population-based data regarding timing of major gross motor milestones up to 5 years were correlated with height, weight and head circumference at birth and 12 months in 48 children with achondroplasia born in Australia and New Zealand between 2000 and 2009. Although as a group children with achondroplasia showed delayed gross motor skill acquisition, within group differences in height, weight or head circumference did not appear to influence timing of gross motor skills before 5 years. The exception was lie to sit transitioning, which appears likely to occur earlier if the child is taller and heavier at 12 months, and later if the child has significant head-to-body disproportion. This is the first study to investigate the relationship between common musculoskeletal impairments associated with achondroplasia and timing of gross motor achievement. Identification of the musculoskeletal factors that exacerbate delays in transitioning from lying to sitting will assist clinicians to provide more proactive assessment, advice and intervention regarding motor skill acquisition for this population. © 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  14. Intracranial artery velocity measurement using 4D PC MRI at 3 T: comparison with transcranial ultrasound techniques and 2D PC MRI

    International Nuclear Information System (INIS)

    Meckel, Stephan; Leitner, Lorenz; Schubert, Tilman; Bonati, Leo H.; Lyrer, Philippe; Santini, Francesco; Stalder, Aurelien F.; Markl, Michael; Wetzel, Stephan G.

    2013-01-01

    4D phase contrast MR imaging (4D PC MRI) has been introduced for spatiotemporal evaluation of intracranial hemodynamics in various cerebrovascular diseases. However, it still lacks validation with standards of reference. Our goal was to compare blood flow quantification derived from 4D PC MRI with transcranial ultrasound and 2D PC MRI. Velocity measurements within large intracranial arteries [internal carotid artery (ICA), basilar artery (BA), and middle cerebral artery (MCA)] were obtained in 20 young healthy volunteers with 4D and 2D PC MRI, transcranial Doppler sonography (TCD), and transcranial color-coded duplex sonography (TCCD). Maximum velocities at peak systole (PSV) and end diastole (EDV) were compared using regression analysis and Bland-Altman plots. Correlation of 4D PC MRI measured velocities was higher in comparison with TCD (r = 0.49-0.66) than with TCCD (0.35-0.44) and 2D PC MRI (0.52-0.60). In mid-BA and ICA C7 segment, a significant correlation was found with TCD (0.68-0.81 and 0.65-0.71, respectively). No significant correlation was found in carotid siphon. On average over all volunteers, PSVs and EDVs in MCA were minimally underestimated compared with TCD/TCCD. Minimal overestimation of velocities was found compared to TCD in mid-BA and ICA C7 segment. 4D PC MRI appears as valid alternative for intracranial velocity measurement consistent with previous reference standards, foremost with TCD. Spatiotemporal averaging effects might contribute to vessel size-dependent mild underestimation of velocities in smaller (MCA), and overestimation in larger-sized (BA and ICA) arteries, respectively. Complete spatiotemporal flow analysis may be advantageous in anatomically complex regions (e.g. carotid siphon) relative to restrictions of ultrasound techniques. (orig.)

  15. Correlation study on waist circumference-triglyceride (WT) index and coronary artery scores in patients with coronary heart disease.

    Science.gov (United States)

    Yang, R-F; Liu, X-Y; Lin, Z; Zhang, G

    2015-01-01

    Coronary disease is analyzed through common lipid profiles, but these analyses fail to account for residual risk due to abdominal weight and elevated TG levels. We aimed to investigate the relationship between the waist circumference × triglyceride index (WT index) and the Coronary Artery Score (CAS) in patients with coronary heart disease. 346 patients in our Cardiology Department were recruited from September 2007 to August 2011 and divided into two groups according to whether the patients presented with metabolic syndrome. We performed coronary angiography using the standard Judkins method. The severity of coronary artery stenosis and the CAS were calculated and analyzed with a computerized quantitative analysis system. The signs index, which includes the body mass index (BMI), waist circumference, hip circumference, waist-hip-ratio, and waist-height-ratio, the blood glucose and blood lipid index of all the patients were collected and used to calculate the WT index (waist circumference x triglyceride index. We performed a correlative analysis with age, gender, body mass index, blood glucose and blood lipid, blood pressure and other risk indicators of all patients as the dependent variables and the CAS as the independent variable. We show that the CAS is positively correlated to the WT index. Several lipid profiles and waist circumference were significantly associated with the CAS. The WT index is correlated to the CAS and is a good predictor for the development of coronary artery disease; it can be applied in the clinic for early intervention in populations at risk for coronary heart disease.

  16. Sub-ns triplet state formation by non-geminate recombination in PSBTBT:PC 70 BM and PCPDTBT:PC 60 BM organic solar cells

    KAUST Repository

    Etzold, Fabian; Howard, Ian A.; Forler, Nina; Melnyk, Anton; Andrienko, Denis; Hansen, Michael Ryan; Laquai, Fré dé ric

    2015-01-01

    The solid-state morphology and photo-generated charge carrier dynamics in low-bandgap polymer:fullerene bulk heterojunction photovoltaic blends using the donor–acceptor type copolymers PCPDTBT or its silicon-substituted analogue PSBTBT as donors are compared by two-dimensional (2D) solid-state nuclear magnetic resonance (NMR) and femto-to microsecond broadband Vis-NIR transient absorption (TA) pump–probe spectroscopy. The 2D solid-state NMR experiments demonstrate that the film morphology of PCPDTBT:PC60BM blends processed with additives such as octanedithiol (ODT) are similar to those of PSBTBT:PC60BM blends in terms of crystallinity, phase segregation, and interfacial contacts. The TA experiments and analysis of the TA data by multivariate curve resolution (MCR) reveal that after exciton dissociation and free charge formation, fast sub-nanosecond non-geminate recombination occurs which leads to a substantial population of the polymer's triplet state. The extent to which triplet states are formed depends on the initial concentration of free charges, which itself is controlled by the microstructure of the blend, especially in case of PCPDTBT:PC60BM. Interestingly, PSBTBT:PC70BM blends show a higher charge generation efficiency, but less triplet state formation at similar free charge carrier concentrations. This indicates that the solid-state morphology and interfacial structures of PSBTBT:PC70BM blends reduces non-geminate recombination, leading to superior device performance compared to optimized PCPDTBT:PC60BM blends.

  17. Sub-ns triplet state formation by non-geminate recombination in PSBTBT:PC 70 BM and PCPDTBT:PC 60 BM organic solar cells

    KAUST Repository

    Etzold, Fabian

    2015-03-02

    The solid-state morphology and photo-generated charge carrier dynamics in low-bandgap polymer:fullerene bulk heterojunction photovoltaic blends using the donor–acceptor type copolymers PCPDTBT or its silicon-substituted analogue PSBTBT as donors are compared by two-dimensional (2D) solid-state nuclear magnetic resonance (NMR) and femto-to microsecond broadband Vis-NIR transient absorption (TA) pump–probe spectroscopy. The 2D solid-state NMR experiments demonstrate that the film morphology of PCPDTBT:PC60BM blends processed with additives such as octanedithiol (ODT) are similar to those of PSBTBT:PC60BM blends in terms of crystallinity, phase segregation, and interfacial contacts. The TA experiments and analysis of the TA data by multivariate curve resolution (MCR) reveal that after exciton dissociation and free charge formation, fast sub-nanosecond non-geminate recombination occurs which leads to a substantial population of the polymer\\'s triplet state. The extent to which triplet states are formed depends on the initial concentration of free charges, which itself is controlled by the microstructure of the blend, especially in case of PCPDTBT:PC60BM. Interestingly, PSBTBT:PC70BM blends show a higher charge generation efficiency, but less triplet state formation at similar free charge carrier concentrations. This indicates that the solid-state morphology and interfacial structures of PSBTBT:PC70BM blends reduces non-geminate recombination, leading to superior device performance compared to optimized PCPDTBT:PC60BM blends.

  18. Dietary energy density in relation to subsequent changes of weight and waist circumference in European men and women

    DEFF Research Database (Denmark)

    Du, Huaidong; van der A, Daphne L; Ginder, Vanessa

    2009-01-01

    BACKGROUND: Experimental studies show that a reduction in dietary energy density (ED) is associated with reduced energy intake and body weight. However, few observational studies have investigated the role of ED on long-term weight and waist circumference change. METHODS AND PRINCIPAL FINDINGS: T...... not prevent weight gain but have a weak yet potentially beneficial effect on the prevention of abdominal obesity as measured by waist circumference....

  19. A relação cintura quadril e o perímetro da cintura associados ao índice de massa corporal em estudo com escolares Waist-hip ratio and waist circumference associated with body mass index in a study with schoolchildren

    Directory of Open Access Journals (Sweden)

    Claudia Soar

    2004-12-01

    Full Text Available O objetivo deste estudo foi determinar os valores percentis de índice de massa corporal (IMC, relação cintura quadril (RCQ e perímetro da cintura (PC e verificar as possíveis correlações existentes entre esses índices em escolares matriculados no Instituto Estadual de Educação, Florianópolis, Santa Catarina, Brasil. Foram investigadas 419 crianças entre sete e nove anos de idade, sendo 215 (51,3% do sexo masculino e 204 (48,7% do sexo feminino. O sexo masculino apresentou maiores valores de IMC, RCQ e PC em relação ao sexo feminino; entretanto, com diferença estatística somente para RCQ e PC. Encontrou-se prevalência de 17,9% de sobrepeso e 6,7% de obesidade. Os índices antropométricos que apresentam maior correlação foram o IMC e o PC (r = 0,87 e p The objectives of this study were to determine the percentile levels of the anthropometric indices body mass index (BMI, waist-hip ratio (WHR, and waist circumference (WC and to verify possible correlations among theses indices in schoolchildren registered at the State Institute of Education, Florianópolis, Santa Catarina State, Brazil. A total of 419 children ages 7 to 9 years were investigated: 215 (51.3% boys and 204 (48.7% girls. BMI, WHR, and WC were higher for boys than for girls. However, the differences were only statistically significant for WHR and WC. Prevalence rates were 17.9% for overweight and 6.7% for obesity. The anthropometric indices with the highest correlation were BMI and WC (r = 0.87 and p < 0.01. For overweight, BMI and WC also presented the strongest correlation (r = 0.74. For obesity, WHR and WC showed the best correlation (r = 0.54.

  20. PC 11: Symbiotic star or planetary nebulae?

    International Nuclear Information System (INIS)

    Gutierrez-Moreno, A.; Moreno, H.; Cortes, G.

    1987-01-01

    PC 11 is an object listed in Perek and Kohoutek (1967) Catalogue of Galactic Planetary Nebulae as PK 331 -5 0 1. Some authors suggest that it is not a planetary nebula, but that it has some characteristics (though not all) of symbiotic stars. We have made photographic, spectrophotometric and spectroscopic observations of PC 11. The analysis of the results suggests that it is a young planetary nebula. (Author)

  1. Social relationships and longitudinal changes in body mass index and waist circumference: the coronary artery risk development in young adults study.

    Science.gov (United States)

    Kershaw, Kiarri N; Hankinson, Arlene L; Liu, Kiang; Reis, Jared P; Lewis, Cora E; Loria, Catherine M; Carnethon, Mercedes R

    2014-03-01

    Few studies have examined longitudinal associations between close social relationships and weight change. Using data from 3,074 participants in the Coronary Artery Risk Development in Young Adults Study who were examined in 2000, 2005, and 2010 (at ages 33-45 years in 2000), we estimated separate logistic regression random-effects models to assess whether patterns of exposure to supportive and negative relationships were associated with 10% or greater increases in body mass index (BMI) (weight (kg)/height (m)(2)) and waist circumference. Linear regression random-effects modeling was used to examine associations of social relationships with mean changes in BMI and waist circumference. Participants with persistently high supportive relationships were significantly less likely to increase their BMI values and waist circumference by 10% or greater compared with those with persistently low supportive relationships after adjustment for sociodemographic characteristics, baseline BMI/waist circumference, depressive symptoms, and health behaviors. Persistently high negative relationships were associated with higher likelihood of 10% or greater increases in waist circumference (odds ratio = 1.62, 95% confidence interval: 1.15, 2.29) and marginally higher BMI increases (odds ratio = 1.50, 95% confidence interval: 1.00, 2.24) compared with participants with persistently low negative relationships. Increasingly negative relationships were associated with increases in waist circumference only. These findings suggest that supportive relationships may minimize weight gain, and that adverse relationships may contribute to weight gain, particularly via central fat accumulation.

  2. A Pc-interface module has been developed that provides an easy way to interface PC

    International Nuclear Information System (INIS)

    Rifai, Ahmad; Gunawan, Usep Setia

    2003-01-01

    A pc-interface module has been developed that provides an easy way to interface PC with I/O devices. This MSC51 micro controller based module accepts series of commands from a personal computer through a serial port. The commands are defined to easily control 24 I/O lines available on the module. These lines can be individually used as either input or output that make the module very verstile. A command is received by the module on ASCII string basis. Each character sent to the module will give an interrupt. The firmware's interrupt handler will store the character in a buffer until end of command character arrives. The firmware then parses and interpreters the command and responses accordingly

  3. Changes in waist circumference and mortality in middle-aged men and women

    DEFF Research Database (Denmark)

    Berentzen, Tina Landsvig; Jakobsen, Marianne Uhre; Halkjaer, Jytte

    2010-01-01

    Waist circumference (WC) adjusted for body mass index (BMI) is positively associated with mortality, but the association with changes in WC is less clear. We investigated the association between changes in WC and mortality in middle-aged men and women, and evaluated the influence from concurrent...

  4. The USL NASA PC R and D development environment standards

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Moreau, Dennis R.

    1984-01-01

    The development environment standards which have been established in order to control usage of the IBM PC/XT development systems and to prevent interference between projects being currently developed on the PC's are discussed. The standards address the following areas: scheduling PC resources; login/logout procedures; training; file naming conventions; hard disk organization; diskette care; backup procedures; and copying policies.

  5. Astronomical Instruments with Two Scales Drawn on Their Common Circumference of Rings in the Joseon Dynasty

    Directory of Open Access Journals (Sweden)

    Byeong-Hee Mihn

    2017-03-01

    Full Text Available This study examines the scale unique instruments used for astronomical observation during the Joseon dynasty. The Small Simplified Armillary Sphere (小簡儀, So-ganui and the Sun-and-Stars Time-Determining Instrument (日星定時儀, Ilseong-jeongsi-ui are minimized astronomical instruments, which can be characterized, respectively, as an observational instrument and a clock, and were influenced by the Simplified Armilla (簡儀, Jianyi of the Yuan dynasty. These two instruments were equipped with several rings, and the rings of one were similar both in size and in scale to those of the other. Using the classic method of drawing the scale on the circumference of a ring, we analyze the scales of the Small Simplified Armillary Sphere and the Sun-and-Stars Time-Determining Instrument. Like the scale feature of the Simplified Armilla, we find that these two instruments selected the specific circumference which can be drawn by two kinds of scales. If Joseon’s astronomical instruments is applied by the dual scale drawing on one circumference, we suggest that 3.14 was used as the ratio of the circumference of circle, not 3 like China, when the ring’s size was calculated in that time. From the size of Hundred-interval disk of the extant Simplified Sundial in Korea, we make a conclusion that the three rings’ diameter of the Sun-and-Stars Time-Determining Instrument described in the Sejiong Sillok (世宗實錄, Veritable Records of the King Sejong refers to that of the middle circle of every ring, not the outer circle. As analyzing the degree of 28 lunar lodges (lunar mansions in the equator written by Chiljeongsan-naepyeon (七政算內篇, the Inner Volume of Calculation of the Motions of the Seven Celestial Determinants, we also obtain the result that the scale of the Celestial-circumference-degree in the Small Simplified Armillary Sphere was made with a scale error about 0.1 du in root mean square (RMS.

  6. Astronomical Instruments with Two Scales Drawn on Their Common Circumference of Rings in the Joseon Dynasty

    Science.gov (United States)

    Mihn, Byeong-Hee; Choi, Goeun; Lee, Yong Sam

    2017-03-01

    This study examines the scale unique instruments used for astronomical observation during the Joseon dynasty. The Small Simplified Armillary Sphere (小簡儀, So-ganui) and the Sun-and-Stars Time-Determining Instrument (日星定時儀, Ilseong-jeongsi-ui) are minimized astronomical instruments, which can be characterized, respectively, as an observational instrument and a clock, and were influenced by the Simplified Armilla (簡儀, Jianyi) of the Yuan dynasty. These two instruments were equipped with several rings, and the rings of one were similar both in size and in scale to those of the other. Using the classic method of drawing the scale on the circumference of a ring, we analyze the scales of the Small Simplified Armillary Sphere and the Sun-and-Stars Time-Determining Instrument. Like the scale feature of the Simplified Armilla, we find that these two instruments selected the specific circumference which can be drawn by two kinds of scales. If Joseon`s astronomical instruments is applied by the dual scale drawing on one circumference, we suggest that 3.14 was used as the ratio of the circumference of circle, not 3 like China, when the ring`s size was calculated in that time. From the size of Hundred-interval disk of the extant Simplified Sundial in Korea, we make a conclusion that the three rings` diameter of the Sun-and-Stars Time-Determining Instrument described in the Sejiong Sillok (世宗實錄, Veritable Records of the King Sejong) refers to that of the middle circle of every ring, not the outer circle. As analyzing the degree of 28 lunar lodges (lunar mansions) in the equator written by Chiljeongsan-naepyeon (七政算內篇, the Inner Volume of Calculation of the Motions of the Seven Celestial Determinants), we also obtain the result that the scale of the Celestial-circumference-degree in the Small Simplified Armillary Sphere was made with a scale error about 0.1 du in root mean square (RMS).

  7. Pc-based car license plate reading

    Science.gov (United States)

    Tanabe, Katsuyoshi; Marubayashi, Eisaku; Kawashima, Harumi; Nakanishi, Tadashi; Shio, Akio

    1994-03-01

    A PC-based car license plate recognition system has been developed. The system recognizes Chinese characters and Japanese phonetic hiragana characters as well as six digits on Japanese license plates. The system consists of a CCD camera, vehicle sensors, a strobe unit, a monitoring center, and an i486-based PC. The PC includes in its extension slots: a vehicle detector board, a strobe emitter board, and an image grabber board. When a passing vehicle is detected by the vehicle sensors, the strobe emits a pulse of light. The light pulse is synchronized with the time the vehicle image is frozen on an image grabber board. The recognition process is composed of three steps: image thresholding, character region extraction, and matching-based character recognition. The recognition software can handle obscured characters. Experimental results for hundreds of outdoor images showed high recognition performance within relatively short performance times. The results confirmed that the system is applicable to a wide variety of applications such as automatic vehicle identification and travel time measurement.

  8. Reengineering a PC-based System into the Mobile Device Product Line

    DEFF Research Database (Denmark)

    Zhang, Weishan; Jarzabek, Stanislaw; Loughran, Neil

    2003-01-01

    There is a growing demand to port existing PC-based software systems to mobile device platforms. Systems running on mobile devices share basic characteristics with their PC-based counterparts, but differ from them in details of user interfaces, application models, etc. Systems running on mobile...... devices must also perform well using less memory than PC-based systems. Mobile devices themselves are different from each other in many ways, too. We describe how we made an existing PC-based City Guide System available on a wide range of mobile devices, in a cost-effective way. We applied "reengineering...... into a product line architecture" approach to achieve the goal. Our product line architecture facilitates reuse via generation. We generate specific City Guide Systems for target platforms including PC, Pocket PC and other mobile devices, from generic meta-components that form the City Guide System product line...

  9. Population dose assessment: characteristics of PC CREAM

    International Nuclear Information System (INIS)

    Alonso, Maria T.; Curti, Adriana R.

    2000-01-01

    This paper presents the main features of the PC CREAM, a program for performing radiological impact assessments due to radioactive discharges into the environment during the operation of radioactive and nuclear facilities. PC CREAM is a suite of six programs that can be used to estimate individual and collective radiation doses. The methodology of PC CREAM is based on updated environmental and dosimetric models, including ICRP 60 recommendations. The models include several exposure pathways and the input files are easy to access. The ergonomics of the program improves the user interaction and makes easier the input of local data. This program is useful for performing sensitivity analysis, siting studies and validation of model comparing the activity concentration output data with environmental monitoring data. The methodology of each module is described as well as the output data. (author)

  10. Eldecalcitol improves mechanical strength of cortical bones by stimulating the periosteal bone formation in the senescence-accelerated SAM/P6 mice - a comparison with alfacalcidol.

    Science.gov (United States)

    Shiraishi, Ayako; Sakai, Sadaoki; Saito, Hitoshi; Takahashi, Fumiaki

    2014-10-01

    Eldecalcitol (ELD), a 2β-hydroxypropyloxy derivative of 1α,25(OH)2D3, is a potent inhibitor of bone resorption that has demonstrated a greater effect at reducing the risk of fracture in osteoporotic patients than alfacalcidol (ALF). In the present study, we used the senescence-accelerated mouse strain P6 (SAM/P6), which has low bone mass caused by osteoblast dysfunction, to evaluate the effect of ELD on cortical bone in comparison with ALF. Four-month-old SAM/P6 mice were given either ELD (0.025 or 0.05μg/kg) or ALF (0.2 or 0.4μg/kg) by oral gavage 5 times/week for 6 weeks. Both ELD and ALF increased serum calcium (Ca) in a dose-dependent manner. Serum Ca levels in the ELD 0.05μg/kg group were comparable to those of the ALF 0.2μg/kg group. ELD 0.05μg/kg significantly improved the bone biomechanical properties of the femur compared with the vehicle control group (pBone histomorphometry revealed that in the femoral endocortical surface, the suppression of bone resorption parameters (N.Oc/BS) and bone formation parameters (MS/BS) by ELD (0.05μg/kg) was greater than that by ALF (0.2μg/kg). In contrast, in the femoral periosteal surface, ELD 0.05μg/kg significantly increased bone formation parameters (BFR/BS, MS/BS) compared with the vehicle control group (pbone not only by inhibiting endocortical bone resorption but also by stimulating the periosteal bone formation in SAM/P6 mice. This article is part of a Special Issue entitled '16th Vitamin D Workshop'. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Pc Card Sony Ericsson: Semiotik Dan Iklan

    OpenAIRE

    Mutmainnah, Yulia

    2014-01-01

    Through advertisement, producers send messages for their product strength to consumers. Those messages are conveyed through various kinds of signs either in the form of language, picture, caption, icon, index, or symbol. There is communicative exchange on GC79 PC Card Sony Ericsson advertisement between sender and receiver. Sender (advertisement maker) of this advertisement makes good use of reward polluter style, which is, persuading comsumers to use PC Card Sony Ericsson product.

  12. PC based uranium enrichment analyser

    International Nuclear Information System (INIS)

    Madan, V.K.; Gopalakrishana, K.R.; Bairi, B.R.

    1991-01-01

    It is important to measure enrichment of unirradiated nuclear fuel elements during production as a quality control measure. An IBM PC based system has recently been tested for enrichment measurements for Nuclear Fuel Complex (NFC), Hyderabad. As required by NFC, the system has ease of calibration. It is easy to switch the system from measuring enrichment of fuel elements to pellets and also automatically store the data and the results. The system uses an IBM PC plug in card to acquire data. The card incorporates programmable interval timers (8253-5). The counter/timer devices are executed by I/O mapped I/O's. A novel algorithm has been incorporated to make the system more reliable. The application software has been written in BASIC. (author). 9 refs., 1 fig

  13. PC imaging system for reactor NDE

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    PC-based systems have been given recent attention by EPRI to organize and manage inspection data (RP-2405-15, TestPro system); integrate with larger, mainframe computers to maintain dialogue for on-site and remote applications; and, in this project, to aid the operator in providing guidance to render decisions on the data. The PC system configuration for this project consisted of a central processing unit (CPU), a hard disk and a floppy disk, 640K bytes of system memory, a high-resolution graphics card and compatible color monitor, and a mouse for operator interaction with software. The software package was written in FORTRAN under the PC Disk Operating System (PC-DOS) and utilized a graphics package for image display. Application of this package to crack-counterbore discrimination in piping welds was investigated. Present automatic techniques utilize signal features from single, A-scan data to render a decision on whether the reflector is benign (i.e., counterbore, weld root) or a crack. However, experienced manual operators in the field make reliable decisions based on the integrated response from the reflector as the transducer is scanned past the suspicious region. Since this software package could display and manipulate ensemble A-scans, spatial features - similar to those used by experts - were developed as discriminants. Ultrasonic responses from intergranular stress corrosion cracks (IGSCCs) were discovered to vary both in time-of-flight and in their amplitude, whereas counterbore responses were more consistent. The software package contains methods for viewing and quantifying these spatial features

  14. METHANE de-NOX for Utility PC Boilers

    Energy Technology Data Exchange (ETDEWEB)

    Bruce Bryan; Serguei Nester; Joseph Rabovitser; Stan Wohadlo

    2005-09-30

    The overall project objective is the development and validation of an innovative combustion system, based on a novel coal preheating concept prior to combustion, that can reduce NO{sub x} emissions to 0.15 lb/million Btu or less on utility pulverized coal (PC) boilers. This NO{sub x} reduction should be achieved without loss of boiler efficiency or operating stability, and at more than 25% lower levelized cost than state-of-the-art SCR technology. A further objective is to ready technology for full-scale commercial deployment to meet the market demand for NO{sub x} reduction technologies. Over half of the electric power generated in the U.S. is produced by coal combustion, and more than 80% of these units utilize PC combustion technology. Conventional measures for NOx reduction in PC combustion processes rely on combustion and post-combustion modifications. A variety of combustion-based NO{sub x} reduction technologies are in use today, including low-NO{sub x} burners (LNBs), flue gas recirculation (FGR), air staging, and natural gas or other fuel reburning. Selective non-catalytic reduction (SNCR) and selective catalytic reduction (SCR) are post-combustion techniques. NO{sub x} reduction effectiveness from these technologies ranges from 30 to 60% and up to 90-93% for SCR. Typically, older wall-fired PC burner units produce NO{sub x} emissions in the range of 0.8-1.6 lb/million Btu. Low-NO{sub x} burner systems, using combinations of fuel staging within the burner and air staging by introduction of overfire air in the boiler, can reduce NO{sub x} emissions by 50-60%. This approach alone is not sufficient to meet the desired 0.15 lb/million Btu NO{sub x} standard with a range of coals and boiler loads. Furthermore, the heavy reliance on overfire air can lead to increased slagging and corrosion in furnaces, particularly with higher-sulfur coals, when LNBs are operated at sub-stoichiometric conditions to reduce fuel-derived NOx in the flame. Therefore, it is desirable

  15. Overexpression of 15-lipoxygenase-1 in PC-3 human prostate cancer cells increases tumorigenesis.

    Science.gov (United States)

    Kelavkar, U P; Nixon, J B; Cohen, C; Dillehay, D; Eling, T E; Badr, K F

    2001-11-01

    The effect of overexpression of 15-lipoxygenase-1 (15-LO-1) was studied in the human prostate cancer cell line, PC-3. Stable PC-3 cell lines were generated by transfection with 15-LO-1-sense (15-LOS), 15-LO-1-antisense (15-LOAS) or vector (Zeo) and selection with Zeocin. After characterization by RT-PCR, western and HPLC, a PC3-15LOS clone was selected that possessed 10-fold 15-LO-1 enzyme activity compared with parental PC-3 cells. The PC3-15LOAS clone displayed little or no 15-LO-1 activity. These PC-3 cell lines were characterized for properties of tumorigenesis. The proliferation rates of the cell lines were as follows: PC3-15LOS > PC-3 = PC3-Zeo > PC3-15LOAS. Addition of a specific 15-LO-1 inhibitor, PD146176, caused a dose-dependent inhibition of proliferation in vitro. Overexpression of 15-LO-1 also caused [(3)H]thymidine incorporation to increase by 4.0-fold (P < 0.01). Compared with parental and PC-3-Zeo cells, PC3-15LOS enhanced whereas PC3-15LOAS reduced the ability of PC-3 cells to grow in an anchorage-independent manner, as assessed by colony formation in soft agar. These data suggested a pro-tumorigenic role for 15-LO-1 in PC-3 cells in vitro. Therefore, to clarify the role of 15-LO-1 in vivo, the effect of 15-LO-1 expression on the growth of tumors in nude mice was investigated. The PC-3 cell lines were inoculated subcutaneously into athymic nude mice. The frequency of tumor formation was increased and the sizes of the tumors formed were much larger in the PC3-15LOS compared with PC3-15LOAS, parental PC-3 and PC-3-Zeo cells. Immunohistochemistry for 15-LO-1 confirmed expression throughout the duration of the experiment. The expression of factor VIII, an angiogenesis marker, in tumor sections was increased in tumors derived from PC3-15LOS cells and decreased in those from PC3-15LOAS cells compared with tumors from parental or Zeo cells. These data further supported the evaluation by ELISA of vascular endothelial growth factor (VEGF) secretion by PC-3

  16. Troubleshooting and Maintaining Your PC All-in-One Desk Reference For Dummies

    CERN Document Server

    Gookin, Dan

    2009-01-01

    Maintaining a PC is important, and troubleshooting a PC can be a challenge. Dan Gookin is great at explaining how to handle common PC problems, and he's provided a complete, plain-English manual in Troubleshooting & Maintaining Your PC All-in-One For Dummies. Liberally laced with Dan's famous humor and clear instructions, Troubleshooting & Maintaining Your PC All-in-One For Dummies is divided into six minibooks covering hardware, software, laptops, Internet, networking, and maintenance. Each one gives you some background on what causes common problems, to help you understand what's wrong as we

  17. A photometric map of interstellar reddening within 100 PC

    Science.gov (United States)

    Perry, C. L.; Johnston, L.; Crawford, D. L.

    1982-12-01

    Color excesses and distances are calculated for 300 bright, northern, late F stars using uvby beta photometric indices. The data allow an extension of the earlier maps by Perry and Johnston of the spatial distribution of interstellar reddening into the local (r less than 100 pc) solar neighborhood. Some definite conclusions are made regarding the distribution of interstellar dust in the northern hemisphere and within 300 pc of the sun by merging these results and the polarimetric observations by Tinbergen (1982) for 180 stars within 35 pc of the sun.

  18. Weight training, aerobic physical activities, and long-term waist circumference change in men

    DEFF Research Database (Denmark)

    Mekary, Rania A; Grøntved, Anders; Despres, Jean-Pierre

    2015-01-01

    OBJECTIVE: Findings on weight training and waist circumference (WC) change are controversial. This study examined prospectively whether weight training, moderate to vigorous aerobic activity (MVAA), and replacement of one activity for another were associated with favorable changes in WC and body ...

  19. Validation of the Omron MIT Elite blood pressure device in a pregnant population with large arm circumference.

    Science.gov (United States)

    James, Lauren; Nzelu, Diane; Hay, Anna; Shennan, Andrew; Kametas, Nikos A

    2017-04-01

    The aim of this study was to evaluate the accuracy of the Omron MIT Elite automated device in pregnant women with an arm circumference of or above 32 cm, using the British Hypertension Society validation protocol. Blood pressure was measured sequentially in 46 women of any gestation requiring the use of a large cuff (arm circumference ≥32 cm) alternating between the mercury sphygmomanometer and the Omron MIT Elite device. The Omron MIT Elite achieved an overall D/D grade with a mean of the device-observer difference being 7.17±6.67 and 9.31±6.59 for systolic and diastolic blood pressure respectively. Interobserver accuracy was 94.6% for systolic and 95% for diastolic readings within 5 mmHg. The Omron MIT Elite overestimates blood pressure and has failed the British Hypertension Society protocol requirements. Therefore, it cannot be recommended for use in pregnant women with an arm circumference of or above 32 cm.

  20. Appropriate neck circumference cut-off points for metabolic syndrome in Turkish patients with type 2 diabetes.

    Science.gov (United States)

    Ozkaya, Ismail; Yardimci, Bulent; Tunckale, Aydin

    2017-12-01

    To investigate the association between neck circumference (NC), overweight, and metabolic syndrome (MS) in Turkish patients with type 2 diabetes. A total of 264 diabetic patients (mean age: 52.9±8.1 years) were recruited from two centers in Istanbul to perform anthropometric measurements, including waist and hip circumference, NC, and body mass index. Blood pressure, fasting glucose, and lipid profile (total cholesterol, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, and triglyceride levels) were determined. NC correlated with waist circumference, systolic blood pressure, and triglycerides in men, whereas NC only correlated with waist circumference in women. Additionally, NC was shown to negatively correlate with high-density lipoprotein cholesterol in both men and women. Receiver operating characteristic analysis showed that the area under the curve for NC and overweight was 0.95 for both men and women (P<0.001). Moreover, a NC of 38cm for men and 37cm for women was the best cut-off point for determining overweight. The area under the curve for NC and MS was 0.87 for men and 0.83 for women (P<0.001). A NC of 39cm for men and 37cm for women was the best cut-off point to determine participants with MS. Our findings suggest a positive correlation of NC with MetS in Turkish patients with type 2 diabetes, and could be a useful and accurate tool to identify MS. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Aspartame-induced apoptosis in PC12 cells.

    Science.gov (United States)

    Horio, Yukari; Sun, Yongkun; Liu, Chuang; Saito, Takeshi; Kurasaki, Masaaki

    2014-01-01

    Aspartame is an artificial sweetner added to many low-calorie foods. The safety of aspartame remains controversial even though there are many studies on its risks. In this study, to understand the physiological effects of trace amounts of artificial sweetners on cells, the effects of aspartame on apoptosis were investigated using a PC12 cell system. In addition, the mechanism of apoptosis induced by aspartame in PC12 cells and effects on apoptotic factors such as cytochrome c, apoptosis-inducing factor, and caspase family proteins were studied by Western blotting and RT-PCR. Aspartame-induced apoptosis in PC12 cells in a dose-dependent manner. In addition, aspartame exposure increased the expressions of caspases 8 and 9, and cytochrome c. These results indicate that aspartame induces apoptosis mainly via mitochondrial pathway involved in apoptosis due to oxigen toxicity. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Predicting waist circumference from body mass index

    Directory of Open Access Journals (Sweden)

    Bozeman Samuel R

    2012-08-01

    Full Text Available Abstract Background Being overweight or obese increases risk for cardiometabolic disorders. Although both body mass index (BMI and waist circumference (WC measure the level of overweight and obesity, WC may be more important because of its closer relationship to total body fat. Because WC is typically not assessed in clinical practice, this study sought to develop and verify a model to predict WC from BMI and demographic data, and to use the predicted WC to assess cardiometabolic risk. Methods Data were obtained from the Third National Health and Nutrition Examination Survey (NHANES and the Atherosclerosis Risk in Communities Study (ARIC. We developed linear regression models for men and women using NHANES data, fitting waist circumference as a function of BMI. For validation, those regressions were applied to ARIC data, assigning a predicted WC to each individual. We used the predicted WC to assess abdominal obesity and cardiometabolic risk. Results The model correctly classified 88.4% of NHANES subjects with respect to abdominal obesity. Median differences between actual and predicted WC were − 0.07 cm for men and 0.11 cm for women. In ARIC, the model closely estimated the observed WC (median difference: − 0.34 cm for men, +3.94 cm for women, correctly classifying 86.1% of ARIC subjects with respect to abdominal obesity and 91.5% to 99.5% as to cardiometabolic risk. The model is generalizable to Caucasian and African-American adult populations because it was constructed from data on a large, population-based sample of men and women in the United States, and then validated in a population with a larger representation of African-Americans. Conclusions The model accurately estimates WC and identifies cardiometabolic risk. It should be useful for health care practitioners and public health officials who wish to identify individuals and populations at risk for cardiometabolic disease when WC data are unavailable.

  3. Phase Behavior, Thermal Stability and Rheological Properties of PPEK/PC Blends

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Phase behavior, thermal stability and rheological properties of the blends of poly(phthalazinone ether ketone) (PPEK)with bisphenol-A polycarbonate (PC) prepared by solution coprecipitation were studied using differential scanning calorimetry (DSC), Frourier-Transform IR spectroscopy (FT-IR), thermogravimetric analysis (TGA) and capillary rheometer. The DSC results indicated that PPEK/PC blends are almost immiscible in full compositions. FT-IR investigation showed that there were no apparent specific interactions between the constituent polymers. The blends keep excellent thermal stability and the addition of PC degrades the thermal stability of blends to some degree. The thermal degradation processes of the blends are much similar to that of PC. The studies on rheological properties of blends show that blending PPEK with PC is beneficial to reducing the melt viscosity and improving the appearance of PPEK.

  4. Aspartame-induced apoptosis in PC12 cells

    OpenAIRE

    Horio, Yukari; Sun, Yongkun; Liu, Chuang; Saito, Takeshi; Kurasaki, Masaaki

    2014-01-01

    Aspartame is an artificial sweetner added to many low-calorie foods. The safety of aspartame remains controversial even though there are many studies on its risks. In this study, to understand the physiological effects of trace amounts of artificial sweetners on cells, the effects of aspartame on apoptosis were investigated using a PC12 cell system. In addition, the mechanism of apoptosis induced by aspartame in PC12 cells and effects on apoptotic factors such as cytochrome c, apoptosis-induc...

  5. Comportamiento térmico y mecánico de mezclas de PC/PET con altos contenidos de PC

    OpenAIRE

    Cornement, Frédéric

    2006-01-01

    Las mezclas de polímeros tienen un interés científico e industrial considerable. Mezclar es una manera muy eficaz para adaptar las propiedades de los polímeros a diferentes circunstancias. El Poli(Etilén Tereftalato) (PET) y el PoliCarbonato (PC) son dos termoplásticos muy importantes. PC tiene una elevada resistencia al impacto y su resistencia a los solventes se mejora cuando se mezcla con PET. Los dos son poliésteres y pueden reaccionar mediante transesterificación en el fundido p...

  6. PC Tutor. Bericht uber ein PC-gestutzes Tutorensystem = PC Tutor. Report on a Tutoring System with Personal Computer. ZIFF Papiere 75.

    Science.gov (United States)

    Fritsch, Helmut

    A project was conducted to increase as well as to professionalize communication between tutors and learners in a West German university's distance education program by the use of personal computers. Two tutors worked on the systematic development of a PC-based correcting system. The goal, apart from developing general language skills in English,…

  7. Treatment of abdominal cellulite and circumference reduction with radiofrequency and dynamic muscle activation.

    Science.gov (United States)

    Wanitphakdeedecha, Rungsima; Iamphonrat, Thanawan; Thanomkitti, Kanchalit; Lektrakul, Nittaya; Manuskiatti, Woraphong

    2015-01-01

    Cellulite is a frequent skin condition for which treatment remains a challenge. A wide variety of treatments are available but most procedures offer suboptimal clinical effect and/or delayed therapeutic outcome. Only few therapeutic options have proven efficacy in the treatment of cellulite. To determine the efficacy and the safety profiles of radiofrequency and dynamic muscle activation technology in treatment of abdominal cellulite and circumference reduction. Twenty-five females with abdominal cellulite received 6 weekly radiofrequency and dynamic muscle activation treatments. Treatment areas included the abdomen and both sides of flanks. Subjects were evaluated using standardized photographs, and measurements of body weight and abdominal circumference at baseline, before every treatment visit, and 1 week and four weeks after the final treatment. Subcutaneous tissue thickness was recorded by ultrasound at baseline and 4 weeks after completion of treatment protocol. Physicians' evaluation and patient's satisfaction of clinical improvement were also measured. All subjects completed the treatment protocol and attended every follow-up visits. There was significant abdominal circumference reduction of 2.96 and 2.52 cm at 1-, and 4-week follow-up visits (p last treatment, the average circumferential reduction was sustained. Most of the patients were rated to have 25-49% improvement at 5th treatment, and 1- and 4-week follow-up visits. Ninety-two percent of the patients were satisfied with the treatment outcome. Radiofrequency provided beneficial effects on the reduction of abdomen and cellulite appearance. The benefit of muscle activation is yet to be determined.

  8. Serial fetal abdominal circumference measurements in predicting normal birth weight in gestational diabetes mellitus.

    LENUS (Irish Health Repository)

    Neff, Karl J

    2013-06-24

    To construct a clinical management matrix using serial fetal abdominal circumference measurements (ACMs) that will predict normal birth weight in pregnancies complicated by gestational diabetes (GDM) and reduce unnecessary ultrasound examination in women with GDM.

  9. PHAST- a spectrum stabilising PC-MCA

    International Nuclear Information System (INIS)

    Mukhopadhyay, P.K.; Satish, P.; Shrivastava, V.D.

    2001-01-01

    Model PHAST, a PC-card with programmable features, incorporates a 100 MHz Wilkinson ADC with conversion gain of 8K. It also provides SCA mode MCS operation. The card caters to the needs of precision nuclear spectroscopy at low to moderate count rates. Spectrum drift may be eliminated by spectrum stabilisation. Proper dead time correction is achieved by Gedcke-Hale or pulse generator based schemes. Multiple cards may be operated together in a single PC in independent operating modes. These cards have onboard histogram memory and updating mechanism. Hence they will usually continue to acquire data in the event of a system crash. (author)

  10. Installation and implementation of PC COSYMA

    International Nuclear Information System (INIS)

    Rossi, J.

    1995-12-01

    COSYMA is a probabilistic reactor accident consequence assessment model developed in the 1980's by the research institutes of the EC countries, primarily by NRPB and KfK. In 1993 a simplified version of the program was released to be implemented on a PC. In the study the PC COSYMA program was applied to calculate as the end points nuclide concentrations, doses received, numbers of health effects, areas affected by countermeasures and other results related to countermeasure strategies. Some results are compared with the results obtained by the ARANO program developed by VTT Energy (Technical Research Centre of Finland) to quarantee proper interpretation of the application. (15 refs.)

  11. Empirically modelled Pc3 activity based on solar wind parameters

    Directory of Open Access Journals (Sweden)

    B. Heilig

    2010-09-01

    Full Text Available It is known that under certain solar wind (SW/interplanetary magnetic field (IMF conditions (e.g. high SW speed, low cone angle the occurrence of ground-level Pc3–4 pulsations is more likely. In this paper we demonstrate that in the event of anomalously low SW particle density, Pc3 activity is extremely low regardless of otherwise favourable SW speed and cone angle. We re-investigate the SW control of Pc3 pulsation activity through a statistical analysis and two empirical models with emphasis on the influence of SW density on Pc3 activity. We utilise SW and IMF measurements from the OMNI project and ground-based magnetometer measurements from the MM100 array to relate SW and IMF measurements to the occurrence of Pc3 activity. Multiple linear regression and artificial neural network models are used in iterative processes in order to identify sets of SW-based input parameters, which optimally reproduce a set of Pc3 activity data. The inclusion of SW density in the parameter set significantly improves the models. Not only the density itself, but other density related parameters, such as the dynamic pressure of the SW, or the standoff distance of the magnetopause work equally well in the model. The disappearance of Pc3s during low-density events can have at least four reasons according to the existing upstream wave theory: 1. Pausing the ion-cyclotron resonance that generates the upstream ultra low frequency waves in the absence of protons, 2. Weakening of the bow shock that implies less efficient reflection, 3. The SW becomes sub-Alfvénic and hence it is not able to sweep back the waves propagating upstream with the Alfvén-speed, and 4. The increase of the standoff distance of the magnetopause (and of the bow shock. Although the models cannot account for the lack of Pc3s during intervals when the SW density is extremely low, the resulting sets of optimal model inputs support the generation of mid latitude Pc3 activity predominantly through

  12. Equipment Qualification and Environment Establishment for COTS Dedication of Safety Grade PC

    International Nuclear Information System (INIS)

    Ahn, Kwang Chul; Bin, Chang Sun; Kwon, Yoon Kwang; Kang, Shin Woo; Koh, Sung Won; Shon, Eui Chan; Jang, Hyun Doo; Song, Il Sup; Lee, Hyun Noh

    2010-08-01

    Safety grade PCs are required for protection systems of SKN 3 and 4 nuclear power plant and subsequent plants. Commercial grade item (CGI) dedication should be carried out to utilize a commercial PC as a safety grade PC of nuclear power plants. This project is aimed to perform the equipment qualification of the commercial PC, and review and improve the quality system of the PC supplier. As a result of the EQ for the CGI dedication, selected military PCs have passed the environment test, the seismic test, and the EMI test required for the digital controllers of nuclear plants. In addition, a walk-through of the quality system of the PC supplier, ISO 9001, was carried out and the quality system was improved. History data for the PC was gathered. As the analysis of the history data showed that operating experience time of the PC is longer than the plant life time, the history data could be used as an evidence of acceptance. After dedicated according to the CGI dedication process, military rugged PCs could be used for safety grade PCs

  13. Reuse of the compact nuclear simulator software under PC with Linux

    International Nuclear Information System (INIS)

    Cha, K. H.; Park, J. C.; Kwon, K. C.; Lee, G. Y.

    2000-01-01

    This study was approached to reuse source programs for a nuclear simulator under PC with Open Source Software(OSS) and to extend its applicability. Source programs in the Compact Nuclear Simulator(CNS), which has been operated for institutional research and training in KAERI, were reused and implemented for Linux-PC environment with the aim of supporting the study. PC with 500 MHz processor and Linux 2.2.5-22 kernel were utilized for the reuse implementation and it was investigated for some applications, through the functional testing for its main functions as interfaced with compact control panels in the current CNS. Development and upgrade of small-scale simulators, establishment of process simulation for PC, and development of prototype predictive simulation, can effectively be enabled with the experience though the reuse implementation was limited to port only CNS programs for PC with Linux

  14. Collagenolytic serine protease PC and trypsin PC from king crab Paralithodes camtschaticus: cDNA cloning and primary structure of the enzymes

    Directory of Open Access Journals (Sweden)

    Rebrikov Denis V

    2004-01-01

    Full Text Available Abstract Background In this paper, we describe cDNA cloning of a new anionic trypsin and a collagenolytic serine protease from king crab Paralithodes camtschaticus and the elucidation of their primary structures. Constructing the phylogenetic tree of these enzymes was undertaken in order to prove the evolutionary relationship between them. Results The mature trypsin PC and collagenolytic protease PC contain 237 (Mcalc 24.8 kDa and 226 amino acid residues (Mcalc 23.5 kDa, respectively. Alignments of their amino acid sequences revealed a high degree of the trypsin PC identity to the trypsin from Penaeus vannamei (approximately 70% and of the collagenolytic protease PC identity to the collagenase from fiddler crab Uca pugilator (76%. The phylogenetic tree of these enzymes was constructed. Conclusions Primary structures of the two mature enzymes from P. camtschaticus were obtained and compared with those of other proteolytic proteins, including some enzymes from brachyurans. A phylogenetic analysis was also carried out. These comparisons revealed that brachyurins are closely related to their vertebrate and bacterial congeners, occupy an intermediate position between them, and their study significantly contributes to the understanding of the evolution and function of serine proteases.

  15. Waist circumference is related to low-grade inflammation in youth

    DEFF Research Database (Denmark)

    Steene-Johannessen, Jostein; Kolle, Elin; Resaland, GK

    2010-01-01

    , insulin, triglycerides and high density lipoprotein cholesterol. Results. HW participants had elevated levels of CRP (mean difference 1.50 mg/l; 95% confidence interval [CI] 0.33 to 2.66), PAI-1 (mean difference 13.3 ng/ml; 95% CI 4.1 to 22.5) and HGF (mean difference 0.29 ng/ml; 95% CI 0.07 to 0...... circumference. CRP, HGF and PAI-1 may be related to the adverse overall metabolic risk profile observed in these children and adolescents....

  16. Approach to Improve Speed of Sound Calculation within PC-SAFT Framework

    DEFF Research Database (Denmark)

    Liang, Xiaodong; Maribo-Mogensen, Bjørn; Thomsen, Kaj

    2012-01-01

    An extensive comparison of SRK, CPA and PC-SAFT for speed of sound in normal alkanes has been performed. The results reveal that PC-SAFT captures the curvature of speed of sound better than cubic EoS but the accuracy is not satisfactory. Two approaches have been proposed to improve PC-SAFT’s accu...... keeping acceptable accuracy for the primary properties, i.e. vapor pressure (2.1%) and liquid density (1.5%). The two approaches have also been applied to methanol, and both give very good results.......An extensive comparison of SRK, CPA and PC-SAFT for speed of sound in normal alkanes has been performed. The results reveal that PC-SAFT captures the curvature of speed of sound better than cubic EoS but the accuracy is not satisfactory. Two approaches have been proposed to improve PC......-SAFT’s accuracy for speed of sound: (i) putting speed of sound data into parameter estimation; (ii) putting speed of sound data into both universal constants regression and parameter estimation. The results have shown that the second approach can significantly improve the speed of sound (3.2%) prediction while...

  17. Recruitment of RNA polymerase II cofactor PC4 to DNA damage sites

    Science.gov (United States)

    Mortusewicz, Oliver; Roth, Wera; Li, Na; Cardoso, M. Cristina; Meisterernst, Michael; Leonhardt, Heinrich

    2008-01-01

    The multifunctional nuclear protein positive cofactor 4 (PC4) is involved in various cellular processes including transcription, replication, and chromatin organization. Recently, PC4 has been identified as a suppressor of oxidative mutagenesis in Escherichia coli and Saccharomyces cerevisiae. To investigate a potential role of PC4 in mammalian DNA repair, we used a combination of live cell microscopy, microirradiation, and fluorescence recovery after photobleaching analysis. We found a clear accumulation of endogenous PC4 at DNA damage sites introduced by either chemical agents or laser microirradiation. Using fluorescent fusion proteins and specific mutants, we demonstrated that the rapid recruitment of PC4 to laser-induced DNA damage sites is independent of poly(ADP-ribosyl)ation and γH2AX but depends on its single strand binding capacity. Furthermore, PC4 showed a high turnover at DNA damages sites compared with the repair factors replication protein A and proliferating cell nuclear antigen. We propose that PC4 plays a role in the early response to DNA damage by recognizing single-stranded DNA and may thus initiate or facilitate the subsequent steps of DNA repair. PMID:19047459

  18. PC12 polarity on biopolymer nanogratings

    International Nuclear Information System (INIS)

    Cecchini, M; Ferrari, A; Beltram, F

    2008-01-01

    Cell differentiation properties are strongly entangled with the morphology and physical properties of the extracellular environment. A complete understanding of this interaction needs artificial scaffolds with controlled nano-/micro-topography. We induced specific topographies by nanoimprint lithography (NIL) on tissue culture polystyrene (TCPS) dishes substrates and, using light microscopy and high-magnification scanning-electron-microscopy, quantitatively compared the changes in PC12 differentiation phenotype induced by the periodicity of the nanopatterns. This analysis revealed that nanogratings reduce the number of neurites produced by PC12 cells upon treatment with NGF and that neuronal bipolarity correlated with an increased stretching of the cell body and a reduced length of the cell neuronal protrusions

  19. IBM PC enhances the world's future

    Science.gov (United States)

    Cox, Jozelle

    1988-01-01

    Although the purpose of this research is to illustrate the importance of computers to the public, particularly the IBM PC, present examinations will include computers developed before the IBM PC was brought into use. IBM, as well as other computing facilities, began serving the public years ago, and is continuing to find ways to enhance the existence of man. With new developments in supercomputers like the Cray-2, and the recent advances in artificial intelligence programming, the human race is gaining knowledge at a rapid pace. All have benefited from the development of computers in the world; not only have they brought new assets to life, but have made life more and more of a challenge everyday.

  20. JEF-PC 2.0. A PC program for viewing evaluated and experimental data

    International Nuclear Information System (INIS)

    Konieczny, M.

    1997-01-01

    In an attempt to make nuclear data more easily accessible to a wider user community, as well as providing a useful tool for experienced users, the NEA has supported the development of PC software for accessing and displaying nuclear data in a user-friendly and intuitive manner. The data contained in JEF-PC version 2.0 is predominantly taken from the Joint Evaluated File (JEF-2.2). The JEF-2.2 library comprises sets of evaluated nuclear data, mainly for fission reactor applications; it contains a number of different types of data, including neutron interaction data, radioactive decay data and fission yield data. The package consists of a central 'driver' program displaying an electronic representation of the Chart of the Nuclides, from which a target nuclide is selected. Through this interface a number of peripheral database modules, containing different categories of basic nuclear data, can be accessed. Cross section data, radioactive decay data, and fission yield data are available in separate modules named CROSS, DECAY and FISSION respectively. (K.A.)

  1. CARES/PC - CERAMICS ANALYSIS AND RELIABILITY EVALUATION OF STRUCTURES

    Science.gov (United States)

    Szatmary, S. A.

    1994-01-01

    The beneficial properties of structural ceramics include their high-temperature strength, light weight, hardness, and corrosion and oxidation resistance. For advanced heat engines, ceramics have demonstrated functional abilities at temperatures well beyond the operational limits of metals. This is offset by the fact that ceramic materials tend to be brittle. When a load is applied, their lack of significant plastic deformation causes the material to crack at microscopic flaws, destroying the component. CARES/PC performs statistical analysis of data obtained from the fracture of simple, uniaxial tensile or flexural specimens and estimates the Weibull and Batdorf material parameters from this data. CARES/PC is a subset of the program CARES (COSMIC program number LEW-15168) which calculates the fast-fracture reliability or failure probability of ceramic components utilizing the Batdorf and Weibull models to describe the effects of multi-axial stress states on material strength. CARES additionally requires that the ceramic structure be modeled by a finite element program such as MSC/NASTRAN or ANSYS. The more limited CARES/PC does not perform fast-fracture reliability estimation of components. CARES/PC estimates ceramic material properties from uniaxial tensile or from three- and four-point bend bar data. In general, the parameters are obtained from the fracture stresses of many specimens (30 or more are recommended) whose geometry and loading configurations are held constant. Parameter estimation can be performed for single or multiple failure modes by using the least-squares analysis or the maximum likelihood method. Kolmogorov-Smirnov and Anderson-Darling goodness-of-fit tests measure the accuracy of the hypothesis that the fracture data comes from a population with a distribution specified by the estimated Weibull parameters. Ninety-percent confidence intervals on the Weibull parameters and the unbiased value of the shape parameter for complete samples are provided

  2. Transforming PC Power Supplies into Smart Car Battery Conditioners

    Science.gov (United States)

    Rodriguez-Ascariz, J. M.; Boquete-Vazquez, L.

    2011-01-01

    This paper describes a laboratory project consisting of a PC power supply modification into an intelligent car-battery conditioner with both wireless and wired networking capabilities. Adding a microcontroller to an average PC power supply transforms it into a flexible, intelligent device that can be configured and that is suitable to keep car…

  3. Efficient Server-Aided 2PC for Mobile Phones

    Directory of Open Access Journals (Sweden)

    Mohassel Payman

    2016-04-01

    Full Text Available Secure Two-Party Computation (2PC protocols allow two parties to compute a function of their private inputs without revealing any information besides the output of the computation. There exist low cost general-purpose protocols for semi-honest parties that can be efficiently executed even on smartphones. However, for the case of malicious parties, current 2PC protocols are significantly less efficient, limiting their use to more resourceful devices. In this work we present an efficient 2PC protocol that is secure against malicious parties and is light enough to be used on mobile phones. The protocol is an adaptation of the protocol of Nielsen et al. (Crypto, 2012 to the Server-Aided setting, a natural relaxation of the plain model for secure computation that allows the parties to interact with a server (e.g., a cloud who is assumed not to collude with any of the parties. Our protocol has two stages: In an offline stage - where no party knows which function is to be computed, nor who else is participating - each party interacts with the server and downloads a file. Later, in the online stage, when two parties decide to execute a 2PC together, they can use the files they have downloaded earlier to execute the computation with cost that is lower than the currently best semi-honest 2PC protocols. We show an implementation of our protocol for Android mobile phones, discuss several optimizations and report on its evaluation for various circuits. For example, the online stage for evaluating a single AES circuit requires only 2.5 seconds and can be further reduced to 1 second (amortized time with multiple executions.

  4. Adiponectin and waist circumference as predictors of insulin-resistance in women.

    Science.gov (United States)

    Bonneau, Graciela A; Pedrozo, Williams R; Berg, Gabriela

    2014-01-01

    The initial disturbance of insulin resistance seems to focus on adipose tissue is a dynamic organ involved in many physiological and metabolic processes. Expresses and secretes a variety of active peptides, adipocytokines. To evaluate the prevalence of insulin-resistance in an healthy urban middle age population and to explore the role of adiponectin, inflammatory biomarkers (hs-CRP) and traditional cardiovascular risk factors as predictors of the insulin-resistance state. We studied of 176 participants (117 women and 59 men, 25-74 years), individuals with diabetes, hypothyroidism or hyperthyroidism, infectious disease, renal, or hepatic neoplasms and pregnant women were excluded. We evaluated glucose, insulin, adiponectin and hs-CRP. We found that 17.2% of individuals presented insulin-resistance. Correlation was found between waist circumference, body mass index, blood pressure and HOMA index (pinsulin-resistance (pinsulin-resistance in men. Besides, postmenopausal women presented higher adiponectin levels than premenopausal 7.63 (4.46-9.58) vs 5.50 (3.83-7.40) μg/ml, p=0.01. Adiponectin and waist circumference are important predictors of insulin-resistance even in healthy non-diabetic women, they may open a new opportunity to improve current risk estimation. Copyright © 2013 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  5. Interaction between genetic predisposition to obesity and dietary calcium in relation to subsequent change in body weight and waist circumference

    DEFF Research Database (Denmark)

    Larsen, Sofus C; Angquist, Lars; Ahluwalia, Tarun Veer Singh

    2014-01-01

    Studies indicate an effect of dietary calcium on change in body weight (BW) and waist circumference (WC), but the results are inconsistent. Furthermore, a relation could depend on genetic predisposition to obesity.......Studies indicate an effect of dietary calcium on change in body weight (BW) and waist circumference (WC), but the results are inconsistent. Furthermore, a relation could depend on genetic predisposition to obesity....

  6. Albuminuria and neck circumference are determinate factors of successful accurate estimation of glomerular filtration rate in high cardiovascular risk patients.

    Directory of Open Access Journals (Sweden)

    Po-Jen Hsiao

    Full Text Available Estimated glomerular filtration rate (eGFR is used for diagnosis of chronic kidney disease (CKD. The eGFR models based on serum creatinine or cystatin C are used more in clinical practice. Albuminuria and neck circumference are associated with CKD and may have correlations with eGFR.We explored the correlations and modelling formulates among various indicators such as serum creatinine, cystatin C, albuminuria, and neck circumference for eGFR.Cross-sectional study.We reviewed the records of patients with high cardiovascular risk from 2010 to 2011 in Taiwan. 24-hour urine creatinine clearance was used as the standard. We utilized a decision tree to select for variables and adopted a stepwise regression method to generate five models. Model 1 was based on only serum creatinine and was adjusted for age and gender. Model 2 added serum cystatin C, models 3 and 4 added albuminuria and neck circumference, respectively. Model 5 simultaneously added both albuminuria and neck circumference.Total 177 patients were recruited in this study. In model 1, the bias was 2.01 and its precision was 14.04. In model 2, the bias was reduced to 1.86 with a precision of 13.48. The bias of model 3 was 1.49 with a precision of 12.89, and the bias for model 4 was 1.74 with a precision of 12.97. In model 5, the bias could be lower to 1.40 with a precision of 12.53.In this study, the predicting ability of eGFR was improved after the addition of serum cystatin C compared to serum creatinine alone. The bias was more significantly reduced by the calculation of albuminuria. Furthermore, the model generated by combined albuminuria and neck circumference could provide the best eGFR predictions among these five eGFR models. Neck circumference can be investigated potentially in the further studies.

  7. Multi drop bus controller for IBM PC/AT

    International Nuclear Information System (INIS)

    Bardik, Yu.I.; Kalistratov, E.N.; Matyushin, A.A.; Obukhov, G.A.; Trofimov, N.N.

    1993-01-01

    The module PC-AT-PBC gives a possibility to create a working place based on the computer IBM PC/AT for testing of hardware which is compatible with the multi drop bus. The KP1830BE31 micro program change turns the module into timing generator for power supply controllers of the UNK correction system. The structure of the module, functional parts, library functions and two application programs have been described. 4 refs., 9 figs

  8. Pengaruh bahan pengisi serat kaca terhadap sifat fisik dan kristalinitas polipaduan PC/ABS

    Directory of Open Access Journals (Sweden)

    Dwi Wahini Nurhajati

    2017-06-01

    Full Text Available This research aimed to determine the effects of the addition of glass fibers on the physical and crystallinity properties of PC/ABS polyblends. The ratio of PC/ABS used in this research was 75/25, while the addition of glass fibers ranged from 0; 5; 10; to 15 phr (based on the weight of PC/ABS. Polyblends of PC/ABS/glass fibers were prepared in a twin screw extruder. The test results showed that density and tensile strength of PC/ABS polyblends increased with an increase in the glass fiber content. The presence of glass fibers decreased MFI and impact strength of these PC/ABS polyblends. The functional groups were determined by the fourier transform infrared (FTIR spectrophotometer while crystallinity was examined using X-ray diffractometer (XRD.

  9. Application of PC-CREAM in the Netherlands. Dose impact due to atmospheric releases

    International Nuclear Information System (INIS)

    Eleveld, H.; Twenhoefel, C.J.W.; Pruppers, M.J.M.

    1999-01-01

    A methodology to assess the radiological impact of routine releases, CREAM, was developed at the National Radiological Protection Board (UK). The software implementation of that methodology to the PC platform, PC-CREAM, has been compared to the Dutch regulation guidelines. The results of the PC-CREAM software and previous RIVM studies are compared for two specific reference situations and eleven naturally occurring radionuclides. The methodology in the submodels in PC-CREAM is also studied and compared to the Dutch regulation guidelines. The assessment of the radiological impact for atmospheric releases using PC-CREAM showed good agreement with the results obtained in previous RIVM studies. Some changes and additions in the methodology are proposed to be able to calculate the radiological impact using PC-CREAM in other relevant reference situations

  10. Ordered array of CoPc-vacancies filled with single-molecule rotors

    Science.gov (United States)

    Xie, Zheng-Bo; Wang, Ya-Li; Tao, Min-Long; Sun, Kai; Tu, Yu-Bing; Yuan, Hong-Kuan; Wang, Jun-Zhong

    2018-05-01

    We report the highly ordered array of CoPc-vacancies and the single-molecule rotors inside the vacancies. When CoPc molecules are deposited on Cd(0001) at low-temperature, three types of molecular vacancies appeared randomly in the CoPc monolayer. Annealing the sample to higher temperature leads to the spontaneous phase separation and self-organized arrangement of the vacancies. Highly ordered arrays of two-molecule vacancies and single-molecule vacancies have been obtained. In particular, there is a rotating CoPc molecule inside each single-molecule vacancy, which constitutes the array of single-molecule rotors. These results provide a new routine to fabricate the nano-machines on a large scale.

  11. APC-PC Combined Scheme in Gilbert Two State Model: Proposal and Study

    Science.gov (United States)

    Bulo, Yaka; Saring, Yang; Bhunia, Chandan Tilak

    2017-04-01

    In an automatic repeat request (ARQ) scheme, a packet is retransmitted if it gets corrupted due to transmission errors caused by the channel. However, an erroneous packet may contain both erroneous bits and correct bits and hence it may still contain useful information. The receiver may be able to combine this information from multiple erroneous copies to recover the correct packet. Packet combining (PC) is a simple and elegant scheme of error correction in transmitted packet, in which two received copies are XORed to obtain the bit location of erroneous bits. Thereafter, the packet is corrected by bit inversion of bit located as erroneous. Aggressive packet combining (APC) is a logic extension of PC primarily designed for wireless communication with objective of correcting error with low latency. PC offers higher throughput than APC, but PC does not correct double bit errors if occur in same bit location of erroneous copies of the packet. A hybrid technique is proposed to utilize the advantages of both APC and PC while attempting to remove the limitation of both. In the proposed technique, applications of APC-PC on Gilbert two state model has been studied. The simulation results show that the proposed technique offers better throughput than the conventional APC and lesser packet error rate than PC scheme.

  12. Thin film pc-Si by aluminium induced crystallization on metallic substrate

    Directory of Open Access Journals (Sweden)

    Cayron C.

    2013-04-01

    Full Text Available Thin film polycrystalline silicon (pc-Si on flexible metallic substrates is promising for low cost production of photovoltaic solar cells. One of the attractive methods to produce pc-Si solar cells consists in thickening a large-grained seed layer by epitaxy. In this work, the deposited seed layer is made by aluminium induced crystallization (AIC of an amorphous silicon (a-Si thin film on metallic substrates (Ni/Fe alloy initially coated with a tantalum nitride (TaN conductive diffusion barrier layer. Effect of the thermal budget on the AIC grown pc-Si seed layer was investigated in order to optimize the process (i.e. the quality of the pc-Si thin film. Structural and optical characterizations were carried out using optical microscopy, μ-Raman and Electron Backscatter Diffraction (EBSD. At optimal thermal annealing conditions, the continuous AIC grown pc-Si thin film showed an average grain size around 15 μm. The grains were preferably (001 oriented which is favorable for its epitaxial thickening. This work proves the feasibility of the AIC method to grow large grains pc-Si seed layer on TaN coated metal substrates. These results are, in terms of grains size, the finest obtained by AIC on metallic substrates.

  13. Tablet PC Support of Students' Learning Styles

    Directory of Open Access Journals (Sweden)

    Shreya Kothaneth

    2012-12-01

    Full Text Available In the context of rapid technology development, it comes as no surprise that technology continues to impact the educational domain, challenging traditional teaching and learning styles. This study focuses on how students with different learning styles use instructional technology, and in particular, the tablet PC, to enhance their learning experience. The VARK model was chosen as our theoretical framework as we analyzed responses of an online survey, both from a quantitative and qualitative standpoint. Results indicate that if used correctly, the tablet PC can be used across different learning styles to enrich the educational experience.

  14. Tour de tailleaugmenté et facteurs de risque cardiovasculaire [Increased waist circumference and cardiovascular risk factors

    Directory of Open Access Journals (Sweden)

    Salima TALEB

    2015-12-01

    Full Text Available Introduction. Obesity evaluated by body mass index (BMI is a recognized cardiovascular risk factor. Studies have shown that adipose tissue deposition in visceral level, reflected by increased waist circumference itself was a cardiometabolic risk factor. Objective. The relationship was studied between a high waist circumference and a cardiovascular risk. Material and Methods. A descriptive and analytical cross-sectional survey was conducted among 200 subjects in 2014 in Tebessa. The questionnaire allowed us to gather the following information: anthropometric measurements, dietary habits, physical activity, smoking, personal and family history ... Blood sample was realized to determine some biochemical parameters. Results. In this study, 60.5% of the subjects had a pathological waist, women were more affected than men (72.86% vs 31.67%, p <0.0001. This prevalence peaked between 47-66 years (p <0.0001. Pathological waist circumference was a predictor of cardiovascular disease (CVD, (RR = 1.71, P = 0.028. This study revealed that 16.53% of subjects with a pathologicalwaistlines had diabetes, 55.5% were hypertensive, 49% had hypertriglyceridemia, 46% low HDL, and 18 % high LDL. In normal weight subjects, 22% had pathological waistline. Conclusion. The prevalence of abdominal obesity is higher among patients consulting in private practice in Tébessa, this requires screening and awareness of people with pathological waistline.

  15. PcG and trxG in plants - friends or foes.

    Science.gov (United States)

    Pu, Li; Sung, Zinmay Renee

    2015-05-01

    The highly-conserved Polycomb group (PcG) and trithorax group (trxG) proteins play major roles in regulating gene expression and maintaining developmental states in many organisms. However, neither the recruitment of Polycomb repressive complexes (PRC) nor the mechanisms of PcG and trxG-mediated gene silencing and activation are well understood. Recent progress in Arabidopsis research challenges the dominant model of PRC2-dependent recruitment of PRC1 to target genes. Moreover, evidence indicates that diverse forms of PRC1, with shared components, are a common theme in plants and mammals. Although trxG is known to antagonize PcG, emerging data reveal that trxG can also repress gene expression, acting cooperatively with PcG. We discuss these recent findings and highlight the employment of diverse epigenetic mechanisms during development in plants and animals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Impact of ambient environment on the electronic structure of CuPc/Au sample

    Science.gov (United States)

    Sinha, Sumona; Mukherjee, M.

    2018-02-01

    The performances of organic devices are crucially connected with their stability in the ambient environment. The impact of 24 h. Ambient environment exposure to the electronic structures of about 12 nm thick CuPc thin film on clean Au substrate have been studied employing UV photoemission spectroscopy technique. X-ray photoemission spectroscopy (XPS) was used to find out the origin of the change of the electronic structures in the sample with the exposure. The XPS study suggests that the oxidation occurs at the CuPc thin film. Due to the adsorption of oxygen in the CuPc film from the ambient air, charge carriers are formed within the CuPc film. Moreover, the XPS results imply that the CuPc film is sufficiently thinner for diffusing oxygen molecules through it and gets physically absorbed on Au substrate during the ambient exposure. Consequently, the hole injection barrier height of pristine CuPc film, grown on Au substrate, is reduced by about 0.50 eV and work-function of the pristine CuPc sample is enhanced by around 0.25 eV in the exposure. The findings will help to understand the mechanism that governs the degradation of performance of CuPc based devices in ambient environment.

  17. PC-based Multiple Information System Interface (PC/MISI) detailed design and implementation plan

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Hall, Philip P.

    1985-01-01

    The design plan for the personal computer multiple information system interface (PC/MISI) project is discussed. The document is intended to be used as a blueprint for the implementation of the system. Each component is described in the detail necessary to allow programmers to implement the system. A description of the system data flow and system file structures is given.

  18. The USL NASA PC R and D project: General specifications of objectives

    Science.gov (United States)

    Dominick, Wayne D. (Editor)

    1984-01-01

    Given here are the general specifications of the objectives of the University of Southwestern Louisiana Data Base Management System (USL/DBMS) NASA PC R and D Project, a project initiated to address future R and D issues related to PC-based processing environments acquired pursuant to the NASA contract work; namely, the IBM PC/XT systems.

  19. Synthesis and characterization of NiPcTSTNa(L) thin films

    Indian Academy of Sciences (India)

    Optical absorption studies of NiPcTSTNa(L) films were performed in the ... the HOMO–LUMO gap of NiPc as 2·41 eV and suggested that the orbitals next to the ..... magnitude of the electrical conductivities and feasibility of preparing these ...

  20. Intake of ruminant trans fatty acids and changes in body weight and waist circumference

    DEFF Research Database (Denmark)

    Hansen, Carsten Palnæs; Berentzen, T L; Halkjær, Jytte

    2012-01-01

    Follow-up studies have suggested that total intake of trans fatty acids (TFA) is a risk factor for gain in body weight and waist circumference (WC). However, in a cross-sectional study individual TFA isomers in adipose tissue had divergent associations with anthropometry. Our objective...

  1. A compact HV supply for field/PC based nuclear instrumentation

    International Nuclear Information System (INIS)

    Manna, A.; Nikhare, D.M.; Madhavi, V.; Bayala, A.K.; Mukhopadhyay, P.K.; Kataria, S.K.

    2001-01-01

    In the recent years, most of the nuclear instruments that were earlier based on NIM Bin standards, are becoming available as PC Add-on cards. This trend is due to the decreasing prices of desktop personal computers and the necessity for automation in radioactivity measurements. This paper describes the design and development of a HV supply module and its PC Add-on card version for field portable/ PC based nuclear instrumentation. The HV supply though being very compact in size meets all the stringent specifications required for detector biasing applications and it has been tested for use with NaI, BF 3 . (author)

  2. Estimation of Polar Cap Potential and the Role of PC Index

    Directory of Open Access Journals (Sweden)

    Ga-Hee Moon

    2012-09-01

    Full Text Available Polar cap potential has long been considered as an indicator for the amount of energy flowing in the magnetosphere-ionosphere system. Thus, the estimation of polar cap potential is important to understand the physical process of the magnetosphere. To estimate the polar cap potential in the Northern Hemisphere, merging electric field by Kan & Lee (1979 is adopted. Relationships between the PC index and calculated merging electric field (E* are examined during full-time and storm-time periods separately. For this purpose Dst, AL, and PC indices and solar wind data are utilized during the period from 1996-2003. From this linear relationship, polar cap potential (Φ* is estimated using the formula by Doyle & Burke (1983. The values are represented as 58.1 ± 26.9 kV for the full-time period and 123.7 ± 84.1 kV for a storm-time period separately. Considering that the average value of polar cap potential of Doyle & Burke (1983 is about 47 kV during moderately quiet intervals with the S3-2 measurements, these results are similar to such. The monthly averaged variation of Dst, AL, and PC indices are then compared. The Dst and AL indices show distinct characteristics with peaks during equinoctial season whereas the average PC index according to the month shows higher values in autumn than in spring. The monthly variations of the linear correlation coefficients between solar wind parameters and geomagnetic indices are also examined. The PC-AL linear correlation coefficient is highest, being 0.82 with peaks during the equinoctial season. As with the AL index, the PC index may also prove useful for predicting the intensity of an auroral substorm. Generally, the linear correlation coefficients are shown low in summer due to conductance differences and other factors. To assess the role of the PC index during the recovery phase of a storm, the relation between the cumulative PC index and the duration is examined. Although the correlation coefficient lowers

  3. Body mass index, waist circumference, body adiposity index, and risk for type 2 diabetes in two populations in Brazil: general and Amerindian.

    Directory of Open Access Journals (Sweden)

    Rafael de Oliveira Alvim

    Full Text Available The use of the anthropometric indices of adiposity, especially body mass index and waist circumference in the prediction of diabetes mellitus has been widely explored. Recently, a new body composition index, the body adiposity index was proposed. The aim of this study was to compare the effectiveness of body mass index, waist circumference, and body adiposity index in the risk assessment for type 2 diabetes mellitus.A total of 1,572 individuals from the general population of Vitoria City, Brazil and 620 Amerindians from the Aracruz Indian Reserve, Brazil were randomly selected. BMI, waist circumference, and BAI were determined according to a standard protocol. Type 2 diabetes mellitus was diagnosed by the presence of fasting glucose ≥126 mg/dL or by the use of antidiabetic drugs.The area under the curve was similar for all anthropometric indices tested in the Amerindian population, but with very different sensitivities or specificities. In women from the general population, the area under the curve of waist circumference was significantly higher than that of the body adiposity index. Regarding risk assessment for type 2 diabetes mellitus, the body adiposity index was a better risk predictor than body mass index and waist circumference in the Amerindian population and was the index with highest odds ratio for type 2 diabetes mellitus in men from the general population, while in women from the general population waist circumference was the best risk predictor.Body adiposity index was the best risk predictor for type 2 diabetes mellitus in the Amerindian population and men from the general population. Our data suggest that the body adiposity index is a useful tool for the risk assessment of type 2 diabetes mellitus in admixture populations.

  4. PC Assisted Anatomical Measurements in 3D Using CT Data

    DEFF Research Database (Denmark)

    Hvidtfeldt, Mogens; Pedersen, Steen

    1999-01-01

    To assess facilities and applications of a programme for a PC based CT measurements in 3D of anatomical angelse in the skeleton.......To assess facilities and applications of a programme for a PC based CT measurements in 3D of anatomical angelse in the skeleton....

  5. Electronic States of IC60BA and PC71BM

    International Nuclear Information System (INIS)

    Sheng Chun-Qi; Wang Peng; Shen Ying; Li Wen-Jie; Li Hong-Nian; Zhang Wen-Hua; Zhu Jun-Fa; Lai Guo-Qiao

    2013-01-01

    We investigate the electronic states of IC 60 BA and PC 71 BM using first-principles calculations and photoelectron spectroscopy (PES) measurements. The energy level structures for all possible isomers are reported and compared with those of C 60 , C 70 and PC 61 BM. The attachment of the side chains can raise the LUMO energies and decrease the HOMO-LUMO gaps, and thus helps to increase the power-conversion efficiency of bulk heterojunction solar cells. In the PES studies, we prepared IC 60 BA and PC 71 BM films on Si:H(111) substrates to construct adsorbate/substrate interfaces describable with the integer charge-transfer (ICT) model. Successful measurements then revealed that one of the most important material properties for an electron acceptor, the energy of the negative integer charge-transfer state (E ICT− ), is 4.31 eV below the vacuum level for PC 71 BM. The E ICT− of IC 60 BA is smaller than 4.14 eV

  6. Kondrashov Gammas. PC database for gamma-rays from radionuclides. Summary documentation

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1996-01-01

    A PC database by V. Kondrashov containing energies and yields of gamma-rays from radionuclides is described. The PC diskette is available from the IAEA Nuclear Data Section, cost free upon request. (author)

  7. BMI, waist circumference at 8 and 12 years of age and FVC and FEV

    NARCIS (Netherlands)

    M.B.M. Bekkers (Marga); A.H. Wijga (Alet); U. Gehring (Ulrike); G.H. Koppelman (Gerard); J.C. de Jongste (Johan); H.A. Smit (Henriëtte); B. Brunekreef (Bert)

    2015-01-01

    textabstractBackground: In adults, overweight is associated with reduced lung function, in children evidence on this association is conflicting. We examined the association of body mass index (BMI) and waist circumference (WC) at age 12, and of persistently (at ages 8 and 12 years) high BMI and

  8. Sonographic correlation of foetal neck circumference and area with gestational age among pregnant women in Port Harcourt, Nigeria.

    Science.gov (United States)

    Abonyi, Obinna Everistus; Eze, Charles Ugwoke; Onwuzu, Sobechukwu W I

    2017-11-01

    The purpose of this study was to create a reference range nomogram of foetal neck circumference (FNC) and foetal neck area (FNA) in a Nigerian population using polynomial regression models. This cross-sectional study involved 723 pregnant women between 14 and 40 weeks of gestation. Axial measurements of the FNC and FNA were obtained in three measurements and the mean taken as the final value and the 5th, 50th and 95th percentiles for each foetal gestational age (FGA) were calculated. FNC and FNA correlated strongly with FGA, biparietal diameter, abdominal circumference, head circumference, and femoral length. Cubic models fitted the FNC vs FGA, and FNA vs. FGA values, and the mathematical relationships are given as: [Formula: see text] [Formula: see text] [Formula: see text]. Nomograms of FNC and FNA are thus generated. Impact statement The foetal neck circumference (FNC) and foetal neck area (FNA) can serve as predictors of foetal gestational age (FGA) since they correlate strongly and positively with FGA and known biometric parameters. The measurements obtained vary with the population studied. This study provides a nomogram of the FNA and FNC for an African population. The values correlate with that of the Caucasian population up to 32 weeks FGA. Interestingly, FNA and FNC measurements demonstrate high correlation but poor agreement in measurements between sonographers. Even though FNA and FNC could be used as predictors of foetal gestational age, the measurements vary significantly between sonographers. This is attributable to the difficulty in obtaining a satisfactory axial view of foetal neck, which is dependent on foetal presentation.

  9. Prostate carcinoma (PC) - an organ-related specific pathological neoplasm

    International Nuclear Information System (INIS)

    Massmann, J.; Funk, A.; Altwein, J.; Praetorius, M.

    2003-01-01

    The organ- and tumour-related specific characteristics of prostate carcinoma (PC) are presented in an overview under various aspects. It is the key for understanding pathological changes, including PC, to consider the subdivision of the prostate into anatomically and functionally distinguishable zones, especially the transitional zone (TZ) and the peripheral zone (PZ). The pseudoneoplastic hyperplasia of the TZ, combined with inflammatory consequences and age-related changes, forms a differential diagnostic challenge to both clinico-radiological diagnosis and macroscopic and microscopic examination. High-degree prostatic intra-epithelial neoplasia (PIN III) and atypical adenomatous hyperplasia (AAH) are presented as precursor lesions of PC with varying significance and assessment. Moreover, there are discussed the following characteristic features of PC: localisation types, focality, volume, progression, double-graduation according to Gleason, tumour stage, and prognosis. The most important prognosis factors of PC (category I) include the categories of the TNM system, such as stage, surgical marginal situation, degree and also the preoperative PSA level as a (poor) substitute for the tumour volume. Potential prognosis parameters (category II) show the tumour volume and the DNS ploidy, while there continues to exist a large number of non-established parameters (category III). The prognostic validity of the pathological examinations depends, on the one hand, on the tissue extent (needle biopsy, transurethral resection (TURP), so-called simple prostatectomy, radical prostatectomy (RPE)) and the prostate zones covered. On the other hand, the prognostic certainty also depends on the tumour-adequate macroscopic and microscopic assessment of an RPE that can only be a partial or complete handling in transversal large-area sections. (orig.) [de

  10. PC Scene Generation

    Science.gov (United States)

    Buford, James A., Jr.; Cosby, David; Bunfield, Dennis H.; Mayhall, Anthony J.; Trimble, Darian E.

    2007-04-01

    AMRDEC has successfully tested hardware and software for Real-Time Scene Generation for IR and SAL Sensors on COTS PC based hardware and video cards. AMRDEC personnel worked with nVidia and Concurrent Computer Corporation to develop a Scene Generation system capable of frame rates of at least 120Hz while frame locked to an external source (such as a missile seeker) with no dropped frames. Latency measurements and image validation were performed using COTS and in-house developed hardware and software. Software for the Scene Generation system was developed using OpenSceneGraph.

  11. Nasal associated lymphoid tissue of the Syrian golden hamster expresses high levels of PrPC.

    Directory of Open Access Journals (Sweden)

    Melissa D Clouse

    Full Text Available The key event in the pathogenesis of the transmissible spongiform encephalopathies is a template-dependent misfolding event where an infectious isoform of the prion protein (PrPSc comes into contact with native prion protein (PrPC and changes its conformation to PrPSc. In many extraneurally inoculated models of prion disease this PrPC misfolding event occurs in lymphoid tissues prior to neuroinvasion. The primary objective of this study was to compare levels of total PrPC in hamster lymphoid tissues involved in the early pathogenesis of prion disease. Lymphoid tissues were collected from golden Syrian hamsters and Western blot analysis was performed to quantify PrPC levels. PrPC immunohistochemistry (IHC of paraffin embedded tissue sections was performed to identify PrPC distribution in tissues of the lymphoreticular system. Nasal associated lymphoid tissue contained the highest amount of total PrPC followed by Peyer's patches, mesenteric and submandibular lymph nodes, and spleen. The relative levels of PrPC expression in IHC processed tissue correlated strongly with the Western blot data, with high levels of PrPC corresponding with a higher percentage of PrPC positive B cell follicles. High levels of PrPC in lymphoid tissues closely associated with the nasal cavity could contribute to the relative increased efficiency of the nasal route of entry of prions, compared to other routes of infection.

  12. Nasal associated lymphoid tissue of the Syrian golden hamster expresses high levels of PrPC.

    Science.gov (United States)

    Clouse, Melissa D; Shikiya, Ronald A; Bartz, Jason C; Kincaid, Anthony E

    2015-01-01

    The key event in the pathogenesis of the transmissible spongiform encephalopathies is a template-dependent misfolding event where an infectious isoform of the prion protein (PrPSc) comes into contact with native prion protein (PrPC) and changes its conformation to PrPSc. In many extraneurally inoculated models of prion disease this PrPC misfolding event occurs in lymphoid tissues prior to neuroinvasion. The primary objective of this study was to compare levels of total PrPC in hamster lymphoid tissues involved in the early pathogenesis of prion disease. Lymphoid tissues were collected from golden Syrian hamsters and Western blot analysis was performed to quantify PrPC levels. PrPC immunohistochemistry (IHC) of paraffin embedded tissue sections was performed to identify PrPC distribution in tissues of the lymphoreticular system. Nasal associated lymphoid tissue contained the highest amount of total PrPC followed by Peyer's patches, mesenteric and submandibular lymph nodes, and spleen. The relative levels of PrPC expression in IHC processed tissue correlated strongly with the Western blot data, with high levels of PrPC corresponding with a higher percentage of PrPC positive B cell follicles. High levels of PrPC in lymphoid tissues closely associated with the nasal cavity could contribute to the relative increased efficiency of the nasal route of entry of prions, compared to other routes of infection.

  13. State of the art of parallel scientific visualization applications on PC clusters; Etat de l'art des applications de visualisation scientifique paralleles sur grappes de PC

    Energy Technology Data Exchange (ETDEWEB)

    Juliachs, M

    2004-07-01

    In this state of the art on parallel scientific visualization applications on PC clusters, we deal with both surface and volume rendering approaches. We first analyze available PC cluster configurations and existing parallel rendering software components for parallel graphics rendering. CEA/DIF has been studying cluster visualization since 2001. This report is part of a study to set up a new visualization research platform. This platform consisting of an eight-node PC cluster under Linux and a tiled display was installed in collaboration with Versailles-Saint-Quentin University in August 2003. (author)

  14. PrPC has nucleic acid chaperoning properties similar to the nucleocapsid protein of HIV-1.

    Science.gov (United States)

    Derrington, Edmund; Gabus, Caroline; Leblanc, Pascal; Chnaidermann, Jonas; Grave, Linda; Dormont, Dominique; Swietnicki, Wieslaw; Morillas, Manuel; Marck, Daniel; Nandi, Pradip; Darlix, Jean-Luc

    2002-01-01

    The function of the cellular prion protein (PrPC) remains obscure. Studies suggest that PrPC functions in several processes including signal transduction and Cu2+ metabolism. PrPC has also been established to bind nucleic acids. Therefore we investigated the properties of PrPC as a putative nucleic acid chaperone. Surprisingly, PrPC possesses all the nucleic acid chaperoning properties previously specific to retroviral nucleocapsid proteins. PrPC appears to be a molecular mimic of NCP7, the nucleocapsid protein of HIV-1. Thus PrPC, like NCP7, chaperones the annealing of tRNA(Lys) to the HIV-1 primer binding site, the initial step of retrovirus replication. PrPC also chaperones the two DNA strand transfers required for production of a complete proviral DNA with LTRs. Concerning the functions of NCP7 during budding, PrPC also mimices NCP7 by dimerizing the HIV-1 genomic RNA. These data are unprecedented because, although many cellular proteins have been identified as nucleic acid chaperones, none have the properties of retroviral nucleocapsid proteins.

  15. Leg length, skull circumference, and the prevalence of dementia in low and middle income countries; a 10/66 population-based cross sectional survey

    Science.gov (United States)

    Prince, Martin; Acosta, Daisy; Dangour, Alan D; Uauy, Ricardo; Guerra, Mariella; Huang, Yueqin; Jacob, KS; Llibre Rodriguez, Juan J.; Salas, Aquiles; Sosa, Ana Luisa; Williams, Joseph D.; Acosta, Isaac; Albanese, Emiliano; Dewey, Michael E.; Ferri, Cleusa P.; Stewart, Robert; Gaona, Ciro; Jotheeswaran, AT.; Senthil Kumar, P; Li, Shuran; Llibre Guerra, Juan C.; Rodriguez, Diana; Rodriguez, Guillermina

    2017-01-01

    Background Adult leg length is influenced by nutrition in the first few years of life. Adult head circumference is an indicator of brain growth. There is a limited literature linking short legs and small skulls to an increased risk for cognitive impairment and dementia in late life. Methods One phase cross-sectional surveys of all over 65 year old residents (n=14,960) in 11 catchment areas in China, India, Cuba, Dominican Republic, Venezuela, Mexico and Peru. The cross-culturally validated 10/66 dementia diagnosis, and a sociodemographic and risk factor questionnaire were administered to all participants, and anthropometric measures taken. Poisson regression was used to calculate prevalence ratios for the effect of leg length and skull circumference upon 10/66 Dementia, controlling for age, gender, education and family history of dementia. Results The pooled meta-analysed fixed effect for leg length (highest vs. lowest quarter) was 0.82 (95% CI, 0.68-0.98) and for skull circumference 0.75 (95% CI, 0.63-0.89). While point estimates varied between sites, the proportion of the variability attributable to heterogeneity between studies as opposed to sampling error (I2) was 0% for leg length and 22% for skull circumference. The effects were independent and not mediated by family history of dementia. The effect of skull circumference was not modified by educational level or gender, and the effect of leg length was not modified by gender. Conclusions Since leg length and skull circumference are said to remain stable throughout adulthood into old age, reverse causality is an unlikely explanation for the findings. Early life nutritional programming, as well as neurodevelopment may protect against neurodegeneration. PMID:20701817

  16. Leg length, skull circumference, and the prevalence of dementia in low and middle income countries: a 10/66 population-based cross sectional survey.

    Science.gov (United States)

    Prince, Martin; Acosta, Daisy; Dangour, Alan D; Uauy, Ricardo; Guerra, Mariella; Huang, Yueqin; Jacob, K S; Rodriguez, Juan J Llibre; Salas, Aquiles; Sosa, Ana Luisa; Williams, Joseph D; Acosta, Isaac; Albanese, Emiliano; Dewey, Michael E; Ferri, Cleusa P; Stewart, Robert; Gaona, Ciro; Jotheeswaran, A T; Kumar, P Senthil; Li, Shuran; Guerra, Juan C Llibre; Rodriguez, Diana; Rodriguez, Guillermina

    2011-03-01

    Adult leg length is influenced by nutrition in the first few years of life. Adult head circumference is an indicator of brain growth. There is a limited literature linking short legs and small skulls to an increased risk for cognitive impairment and dementia in late life. One phase cross-sectional surveys were carried out of all residents aged over 65 years in 11 catchment areas in China, India, Cuba, Dominican Republic, Venezuela, Mexico and Peru (n = 14,960). The cross-culturally validated 10/66 dementia diagnosis, and a sociodemographic and risk factor questionnaire were administered to all participants, and anthropometric measures taken. Poisson regression was used to calculate prevalence ratios for the effect of leg length and skull circumference upon 10/66 dementia, controlling for age, gender, education and family history of dementia. The pooled meta-analyzed fixed effect for leg length (highest vs. lowest quarter) was 0.82 (95% CI, 0.68-0.98) and for skull circumference 0.75 (95% CI, 0.63-0.89). While point estimates varied between sites, the proportion of the variability attributable to heterogeneity between studies as opposed to sampling error (I2) was 0% for leg length and 22% for skull circumference. The effects were independent and not mediated by family history of dementia. The effect of skull circumference was not modified by educational level or gender, and the effect of leg length was not modified by gender. Since leg length and skull circumference are said to remain stable throughout adulthood into old age, reverse causality is an unlikely explanation for the findings. Early life nutritional programming, as well as neurodevelopment may protect against neurodegeneration.

  17. Wind-induced cable vibrations and countermeasures of cables of PC cable-stayed bridge. PC syachokyo keburu no kaze ni yoru shindo to sono taisaku

    Energy Technology Data Exchange (ETDEWEB)

    Yoneda, M. (Kawada Industries Inc., Tokyo (Japan))

    1994-05-01

    In recent years, long span of cable-stayed bridges is remarkable. The wind-induced cable vibration called as line vibration and wake galloping was given as an important problem not only in the steel cable-stayed bridges but also in the PC cable-stayed bridges. The technical engineers in design of the cable-stayed bridges have many times to confront the problems on the vibration control of cables, it is considered that sufficient understand of the wind-induced vibration and countermeasures for cables of the PC cable-stayed bridges is necessary. Many reports on the countermeasure examples and trend of vibration control centred on cables of the cable-stayed bridges have been published. In this paper, the wind-induced vibration of cables in the cable-stayed bridges was reviewed, the examples of countermeasures of vibration control on cables in the PC cable-stayed bridges was mainly introduced. The remaining tasks and future prospects on vibration control of the PC cable-stayed bridges were described. 14 refs., 13 figs., 4 tabs.

  18. Is there a link between proprotein convertase PC7 activity and human lipid homeostasis?

    Directory of Open Access Journals (Sweden)

    Johann Guillemot

    2014-01-01

    Full Text Available A genome-wide association study suggested that a R504H mutation in the proprotein convertase PC7 is associated with increased circulating levels of HDL and reduced triglycerides in black Africans. Our present results show that PC7 and PC7-R504H exhibit similar processing of transferrin receptor-1, proSortilin, and apolipoprotein-F. Plasma analyses revealed no change in the lipid profiles, insulin or glucose of wild type and PC7 KO mice. Thus, the R504H mutation does not modify the proteolytic activity of PC7. The mechanisms behind the implication of PC7 in the regulation of human HDL, triglycerides and in modifying the levels of atherogenic small dense LDL remain to be elucidated.

  19. Brugervejledning til pc-programmet STLRAMME

    DEFF Research Database (Denmark)

    Buhelt, M.

    Pc-programmet STLRAMME supplerer SBI-anvisning 187, 'Simple stålrammebygninger. Dimensionering og udførelse'. Programmet kan anvendes til dimensionering af stålrammebygninger med andre mål end dem, der er medtaget i anvisningens tabeller; men det erstatter kun stålramme- og åsetabellerne, ikke an...

  20. Dielectric and Energy Storage Properties of the Heterogeneous P(VDF-HFP)/PC Composite Films

    Science.gov (United States)

    Zhao, Xiaojia; Peng, Guirong; Zhan, Zaiji

    2017-12-01

    Polymer-based materials with a high discharge energy and low energy loss have attracted considerable attention for energy storage applications. A new class of polymer-based composite films composed of amorphous polycarbonate (PC) and poly(vinylidene fluoride-hexafluoropropylene) [P(VDF-HFP)] has been fabricated by simply solution blending followed by thermal treatment under vacuum. The results show that the diameter of the spherical phase for PC and the melting temperature of P(VDF-HFP) increase, and the crystallinity and crystallization temperature of P(VDF-HFP) decrease with increasing PC content. The phase transition from the polar β phase to weak polarity γ phase is induced by PC addition. Moreover, the Curie temperature of the P(VDF-HFP)/PC composite films shifts to a lower temperature. With the addition of PC, the permittivity, polarization and discharge energy of the P(VDF-HFP)/PC composite films slightly decrease. However, the energy loss is significantly reduced.

  1. BMI, waist circumference at 8 and 12 years of age and FVC and FEV

    NARCIS (Netherlands)

    Bekkers, Marga B.; Wijga, Alet H.; Gehring, Ulrike; Koppelman, Gerard H.; de Jongste, Johan C.; Smit, Henriette A.; Brunekreef, Bert

    2015-01-01

    Background: In adults, overweight is associated with reduced lung function, in children evidence on this association is conflicting. We examined the association of body mass index (BMI) and waist circumference (WC) at age 12, and of persistently (at ages 8 and 12 years) high BMI and large WC, with

  2. Accelerated 3D-OSEM image reconstruction using a Beowulf PC cluster for pinhole SPECT

    International Nuclear Information System (INIS)

    Zeniya, Tsutomu; Watabe, Hiroshi; Sohlberg, Antti; Iida, Hidehiro

    2007-01-01

    A conventional pinhole single-photon emission computed tomography (SPECT) with a single circular orbit has limitations associated with non-uniform spatial resolution or axial blurring. Recently, we demonstrated that three-dimensional (3D) images with uniform spatial resolution and no blurring can be obtained by complete data acquired using two-circular orbit, combined with the 3D ordered subsets expectation maximization (OSEM) reconstruction method. However, a long computation time is required to obtain the reconstruction image, because of the fact that 3D-OSEM is an iterative method and two-orbit acquisition doubles the size of the projection data. To reduce the long reconstruction time, we parallelized the two-orbit pinhole 3D-OSEM reconstruction process by using a Beowulf personal computer (PC) cluster. The Beowulf PC cluster consists of seven PCs connected to Gbit Ethernet switches. Message passing interface protocol was utilized for parallelizing the reconstruction process. The projection data in a subset are distributed to each PC. The partial image forward-and back-projected in each PC is transferred to all PCs. The current image estimate on each PC is updated after summing the partial images. The performance of parallelization on the PC cluster was evaluated using two independent projection data sets acquired by a pinhole SPECT system with two different circular orbits. Parallelization using the PC cluster improved the reconstruction time with increasing number of PCs. The reconstruction time of 54 min by the single PC was decreased to 10 min when six or seven PCs were used. The speed-up factor was 5.4. The reconstruction image by the PC cluster was virtually identical with that by the single PC. Parallelization of 3D-OSEM reconstruction for pinhole SPECT using the PC cluster can significantly reduce the computation time, whereas its implementation is simple and inexpensive. (author)

  3. Reduction of seismic response long-span PC cable-stayed bridge by passive dampers; Damper ni yoru saidai PC shachokyo no jishinji oto no teigen

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, T.; Yamanobe, S.; Niihara, Y. [Kajima Corp., Tokyo (Japan)

    1994-10-31

    It is important in designing a PC cable-stayed bridge to properly estimate the seismic response of the bridge for reduction of the response. In this paper, an improvement of the seismic resistance of PC cable-stayed bridges when dampers are installed between the deck and piers and lateral vibration of the deck is restricted is investigated using a time history response model. PC cable-stayed bridges with a span length of 400 m, particularly two types of bridges of harp and semi-harp are investigated and the following is found by analyzing the case where there are installed hysteresis type dampers (with 1 cm yield displacement and secondary rigidity assumed to be 1/10 times that of initial rigidity, the initial rigidity being parametrically changed.) or viscous type dampers (a damping factor is changed.) The result shows that the dampers can reduce the seismic response of a PC cable-stayed bridge and that a semi-harp configuration of stay cables where stay cable members are substantially vertically arranged is more effective than a harp configuration for the seismic performance of PC cable-stayed bridges. The damper partly bear inertial force of the bridge upon earthquake whereby tension of the stay cable members is reduced and bending moment of the deck is reduced. There is existing an optimum characteristic value of the damper concerning the bending moment of the piers. 5 refs., 7 figs., 2 tabs.

  4. The short circumference damping ring design for the ILC

    CERN Document Server

    Korostelev, Maxim S; Kuriki, Masao; Kuroda, Shigeru; Naito, Takashi; Ross, Marc; Urakawa, Junji; Zimmermann, Frank

    2005-01-01

    The ILC damping ring tentative design is driven by the operational scenario of the main linac, the beam-dynamics demand of producing a stable and high-quality beam, the injection/extraction scheme and the kicker performance. In this paper, a short circumference damping ring design based on TME cells is described. The ring accommodates injection kickers which provide a flat top of 280 nsec and a 60 nsec rise and fall time and very fast strip-line kickers for beam extraction with a 2 nsec rise and fall time for 3-MHz operation. The potential impact of collective effects and the possible degradation of the dynamic aperture by nonlinear-wiggler fields are estimated.

  5. A NICE approach to managing large numbers of desktop PC's

    International Nuclear Information System (INIS)

    Foster, David

    1996-01-01

    The problems of managing desktop systems are far from resolved. As we deploy increasing numbers of systems, PC's Mackintoshes and UN*X Workstations. This paper will concentrate on the solution adopted at CERN for the management of the rapidly increasing numbers of desktop PC's in use in all parts of the laboratory. (author)

  6. Bone geometry in young male and female football players: a peripheral quantitative computed tomography (pQCT) study.

    Science.gov (United States)

    Lozano-Berges, Gabriel; Matute-Llorente, Ángel; Gómez-Bruton, Alejandro; González-Agüero, Alex; Vicente-Rodríguez, Germán; Casajús, José A

    2018-05-08

    The present study shows that football practice during growth may improve bone geometry in male and female football players. However, only females had better bone strength in comparison with controls. The aim of this study was to compare bone geometry in adolescent football players and controls. A total of 107 football players (71 males/36 females; mean age 12.7 ± 0.6/12.7 ± 0.6 years) and 42 controls (20 males/22 females; mean age 13.1 ± 1.4/12.7 ± 1.3 years) participated in this study. Total and trabecular volumetric bone mineral content (Tt.BMC/Tb.BMC), cross-sectional area (Tt.Ar/Tb.Ar), and bone strength index (BSI) were measured at 4% site of the non-dominant tibia by peripheral quantitative computed tomography (pQCT). Moreover, Tt.BMC, cortical BMC (Ct.BMC), Tt.Ar, cortical Ar (Ct.Ar), cortical thickness (Ct.Th), periosteal circumference (PC), endosteal circumference (EC), fracture load in X-axis, and polar strength strain index (SSIp) were measured at 38% site of the tibia. Multivariate analyses of covariance were used to compare bone pQCT variables between football players and controls using the tibia length and maturity offset as covariates. Female football players demonstrated 13.8-16.4% higher BSI, Ct.Th, fracture load in X-axis, and SSIp than controls (p  .0036). In relation to bone mineral content and area, male football players showed 8.8% higher Tt.Ar and Tb.Ar at the 4% site of the tibia when compared to controls; whereas 13.8-15.8% higher Tt.BMC, Ct.BMC, and Ct.Ar at the 38% site of the tibia were found in female football players than controls (p female adolescent football players presented better bone geometry and strength values than controls. In contrast, only bone geometry was higher in male football players than controls.

  7. The Weathering Study of PC/ASA Alloy For Automotive Exterior Applications

    Directory of Open Access Journals (Sweden)

    Sinan Öztürk

    2017-10-01

    Full Text Available Polycarbonates (PC are used in automotive industry due to high physical and mechanical properties like high impact resistance and ductility. Polycarbonates are blended with ABS (Acrylonitrile-Butadiene-Styrene and ASA (Acrylonitrile-Styrene-Acrylate terpolymers for interior and exterior applications of automotive components to achieve good physical and mechanical properties. Other reason for choosing such alloys for interior applications is the IZOD impact resistance requirement higher than 40kJ/m2. Recently, grades of PC/ASA with UV stabilized are developed for non-painted exterior applications. The aim of our study is to investigate whether new developed PC/ASA could be chosen for exterior applications of automotive industry. In this study, the samples are prepared from injection molding and the weathering performance of PC/ASA was tested by a weather-o-meter for 1500h at a total of 1890 kJ/m2 at 340nm with a cut-off filter at λ<290nm. The results are evaluated by FT-IR, DSC, TGA and SEM. It has been observed that UV degradation of PC/ASA leads to several major changes in its IR spectrum like broad bands occurred in the hydroxyl region around 3300 cm-1, and carbonyl stretching region increased around 1728 cm-1. The main degradations were based on photo-oxidation and photo-Fries rearrangement of PC. In our study, the photo-oxidation was followed by the color shift to yellowing of the polymer.

  8. Performance Evaluation of a Multipurpose Bare PC Gateway

    DEFF Research Database (Denmark)

    Tsetse, Anthony; Appiah-Kubi, Patrick; Loukili, Alae

    2015-01-01

    . Different solutions (6to4 tunneling, IVI translation, NAT64, DNS64 etc.), have being proposed but these are all standalone systems. In this paper we discuss the design,implementation and performance evaluation of a multipurpose Bare PC Gateway which incorporates Network Address translation (NAT), 6to4...... results indicate a relatively better performance (18%-45%) of the Bare PC gateway compared to a Linux gateway (running the functionalities as standalone systems). We believe the proposed solution could easily scale to wide area networks and also provide a cost efficient solution...

  9. On petroleum fluid characterization with the PC-SAFT equation of state

    DEFF Research Database (Denmark)

    Liang, Xiaodong; Yan, Wei; Thomsen, Kaj

    2014-01-01

    The perturbed-chain statistical associating fluid theory (PC-SAFT) equation of state has shown promising results for describing complex phase behaviors and high pressure properties of various systems. It has been proposed as an alternative to the classical cubic equations of state in the petroleum...... industry. It is, however, far from a simple task to develop a sophisticated oil characterization method for the PC-SAFT EOS. In this work, in order to answer some fundamental questions of developing new characterization methods for PC-SAFT, six methods are proposed to estimate the model parameters...

  10. Practical Pocket PC Application w/Biometric Security

    Science.gov (United States)

    Logan, Julian

    2004-01-01

    I work in the Flight Software Engineering Branch, where we provide design and development of embedded real-time software applications for flight and supporting ground systems to support the NASA Aeronautics and Space Programs. In addition, this branch evaluates, develops and implements new technologies for embedded real-time systems, and maintains a laboratory for applications of embedded technology. The majority of microchips that are used in modern society have been programmed using embedded technology. These small chips can be found in microwaves, calculators, home security systems, cell phones and more. My assignment this summer entails working with an iPAQ HP 5500 Pocket PC. This top-of-the-line hand-held device is one of the first mobile PC's to introduce biometric security capabilities. Biometric security, in this case a fingerprint authentication system, is on the edge of technology as far as securing information. The benefits of fingerprint authentication are enormous. The most significant of them are that it is extremely difficult to reproduce someone else's fingerprint, and it is equally difficult to lose or forget your own fingerprint as opposed to a password or pin number. One of my goals for this summer is to integrate this technology with another Pocket PC application. The second task for the summer is to develop a simple application that provides an Astronaut EVA (Extravehicular Activity) Log Book capability. The Astronaut EVA Log Book is what an astronaut would use to report the status of field missions, crew physical health, successes, future plans, etc. My goal is to develop a user interface into which these data fields can be entered and stored. The applications that I am developing are created using eMbedded Visual C++ 4.0 with the Pocket PC 2003 Software Development Kit provided by Microsoft.

  11. File list: InP.Prs.50.AllAg.PC-3 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Prs.50.AllAg.PC-3 hg19 Input control Prostate PC-3 SRX539667,SRX084520,SRX43319...9,SRX433195,SRX1021636,SRX1021637,SRX181768,SRX540851 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.Prs.50.AllAg.PC-3.bed ...

  12. Demonstration of a PC 25 Fuel Cell in Russia

    Energy Technology Data Exchange (ETDEWEB)

    John C. Trocciola; Thomas N. Pompa; Linda S. Boyd

    2004-09-01

    This project involved the installation of a 200kW PC25C{trademark} phosphoric-acid fuel cell power plant at Orgenergogaz, a Gazprom industrial site in Russia. In April 1997, a PC25C{trademark} was sold by ONSI Corporation to Orgenergogaz, a subsidiary of the Russian company ''Gazprom''. Due to instabilities in the Russian financial markets, at that time, the unit was never installed and started by Orgenergogaz. In October of 2001 International Fuel Cells (IFC), now known as UTC Fuel Cells (UTCFC), received a financial assistance award from the United States Department of Energy (DOE) entitled ''Demonstration of PC 25 Fuel Cell in Russia''. Three major tasks were part of this award: the inspection of the proposed site and system, start-up assistance, and installation and operation of the powerplant.

  13. Umbilical Cord Serum 25-Hydroxyvitamin D Concentrations and Relation to Birthweight, Head Circumference and Infant Length at Age 14 Days

    DEFF Research Database (Denmark)

    Dalgård, Christine; Petersen, Maria Skaalum; Steuerwald, Ulrike

    2016-01-01

    infants. In the third trimester, the pregnant women completed questionnaires, and clinical examination included birthweight, head circumference, and infant length at age 14 days. RESULTS: Fifty-three percent of the newborn population had UC 25(OH)D ... linear regression models with adjustment for pre-pregnancy BMI, sex, parity, gestational age, or infant age at examination, season of birth, smoking, gestational diabetes, examiner, and cohort identity, we found no relationship between birthweight or head circumference and UC 25(OH)D. However, infants...

  14. Physical and mechanical properties of mortars containing PET and PC waste aggregates.

    Science.gov (United States)

    Hannawi, Kinda; Kamali-Bernard, Siham; Prince, William

    2010-11-01

    Non-biodegradable plastic aggregates made of polycarbonate (PC) and polyethylene terephthalate (PET) waste are used as partial replacement of natural aggregates in mortar. Various volume fractions of sand 3%, 10%, 20% and 50% are replaced by the same volume of plastic. This paper investigates the physical and mechanical properties of the obtained composites. The main results of this study show the feasibility of the reuse of PC and PET waste aggregates materials as partial volume substitutes for natural aggregates in cementitious materials. Despite of some drawbacks like a decrease in compressive strength, the use of PC and PET waste aggregates presents various advantages. A reduction of the specific weight of the cementitious materials and a significant improvement of their post-peak flexural behaviour are observed. The calculated flexural toughness factors increase significantly with increasing volume fraction of PET and PC-aggregates. Thus, addition of PC and PET plastic aggregates in cementitious materials seems to give good energy absorbing materials which is very interesting for several civil engineering applications like structures subjected to dynamic or impact efforts. The present study has shown quite encouraging results and opened new way for the recycling of PC waste aggregate in cement and concrete composites. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Transfer and development of the PC version of ABAQUS program

    International Nuclear Information System (INIS)

    Li Xiaofeng; Zhu Yuqiao

    1998-01-01

    The transfer and development of the PC version of ABAQUS,a large nonlinear mechanical finite element analysis program, are carried out. Some special problem such as difference of the floating data format in different computers and the computer's unusual dead halt during the data transfer is solved and the visualized I/O capability is added in the redevelopment. Thus, by utilizing the visual capability, the intensity of analysis works is reduced, and the correctness of analysis is ensured. The PC ABAQUS are tested by the standard examples from VAX version of ABAQUS and the calculation results are correct. The results of calculation of stress and deformation for CEFR shell structure with PC ABAQUS and ADINA codes agree very well

  16. State of the art of parallel scientific visualization applications on PC clusters; Etat de l'art des applications de visualisation scientifique paralleles sur grappes de PC

    Energy Technology Data Exchange (ETDEWEB)

    Juliachs, M

    2004-07-01

    In this state of the art on parallel scientific visualization applications on PC clusters, we deal with both surface and volume rendering approaches. We first analyze available PC cluster configurations and existing parallel rendering software components for parallel graphics rendering. CEA/DIF has been studying cluster visualization since 2001. This report is part of a study to set up a new visualization research platform. This platform consisting of an eight-node PC cluster under Linux and a tiled display was installed in collaboration with Versailles-Saint-Quentin University in August 2003. (author)

  17. Arnebia euchroma ointment can reduce abdominal fat thickness and abdominal circumference of overweight women: A randomized controlled study.

    Science.gov (United States)

    Siavash, Mansour; Naseri, Mohsen; Rahimi, Mojgan

    2016-01-01

    Obesity is a worldwide health problem which is associated with a lot of complications. One of these comorbidities is the metabolic syndrome that is in correlation with abdominal fat thickness and waist circumference. Various methods were used to reduce abdominal fat thickness such as liposuction. A noninvasive method is the topical agent. In this study, we investigated the effectiveness of Arnebia euchroma (AE) ointment on the abdominal fat thickness. This study was a double-blind clinical trial which was done at the endocrinology clinic in Khorshid Hospital, Isfahan, Iran, in 2014. After explaining the procedure and obtaining informed consent, the candidates were randomly divided into the case and control groups. The participants of the case and control groups applied AE ointment or placebo for 6 weeks on their abdominal area. Body mass index, waist and buttock circumference, and abdominal fat thickness were measured in both case and control groups at their first visit and then at the next 2, 4, and 6 weeks. We used t -test for comparing parametric variables between groups, paired t -test for changes from baseline to final, and repeated measure ANOVA for changes at different steps. Sixty female candidates participated in this study (thirty in each group). Ten patients left the study and fifty participants finished the trial. At the end of the study, participants had a significant weight loss (2.96 ± 1.6 kg, P Abdominal circumference also decreased significantly in the participants (11.3 ± 6.7 cm, P abdominal fat thickness decreased significantly in the participants (2.3 ± 1.1 cm, P abdominal fat thickness as well as the waist circumference without causing any side effect.

  18. Feasibility study of BES data processing and physics analysis on a PC/Linux platform

    International Nuclear Information System (INIS)

    Rong Gang; He Kanglin; Zhao Jiawei; Heng Yuekun; Zhang Chun

    1999-01-01

    The authors report a feasibility study of off-line BES data processing (data reconstruction and Detector simulation) on a PC/Linux platform and an application of the PC/Linux system in D/Ds physics analysis. The authors compared the results obtained from the PC/Linux with that from HP workstation. It shows that PC/Linux platform can do BES data offline analysis as good as UNIX workstation do, but it is much powerful and economical

  19. Waist circumference adjusted for body mass index and intra-abdominal fat mass

    DEFF Research Database (Denmark)

    Berentzen, Tina Landsvig; Ängquist, Lars; Kotronen, Anna

    2012-01-01

    The association between waist circumference (WC) and mortality is particularly strong and direct when adjusted for body mass index (BMI). One conceivable explanation for this association is that WC adjusted for BMI is a better predictor of the presumably most harmful intra-abdominal fat mass (IAFM......) than WC alone. We studied the prediction of abdominal subcutaneous fat mass (ASFM) and IAFM by WC alone and by addition of BMI as an explanatory factor....

  20. Development a computer codes to couple PWR-GALE output and PC-CREAM input

    Science.gov (United States)

    Kuntjoro, S.; Budi Setiawan, M.; Nursinta Adi, W.; Deswandri; Sunaryo, G. R.

    2018-02-01

    Radionuclide dispersion analysis is part of an important reactor safety analysis. From the analysis it can be obtained the amount of doses received by radiation workers and communities around nuclear reactor. The radionuclide dispersion analysis under normal operating conditions is carried out using the PC-CREAM code, and it requires input data such as source term and population distribution. Input data is derived from the output of another program that is PWR-GALE and written Population Distribution data in certain format. Compiling inputs for PC-CREAM programs manually requires high accuracy, as it involves large amounts of data in certain formats and often errors in compiling inputs manually. To minimize errors in input generation, than it is make coupling program for PWR-GALE and PC-CREAM programs and a program for writing population distribution according to the PC-CREAM input format. This work was conducted to create the coupling programming between PWR-GALE output and PC-CREAM input and programming to written population data in the required formats. Programming is done by using Python programming language which has advantages of multiplatform, object-oriented and interactive. The result of this work is software for coupling data of source term and written population distribution data. So that input to PC-CREAM program can be done easily and avoid formatting errors. Programming sourceterm coupling program PWR-GALE and PC-CREAM is completed, so that the creation of PC-CREAM inputs in souceterm and distribution data can be done easily and according to the desired format.

  1. Electrochemistry and spectroelectrochemistry of tert-butylcalix[4]arene bridged bis double-decker lutetium(III) phthalocyanine, Lu2Pc4 and dimeric lutetium(III) phthalocyanine, Lu2Pc2(OAc)2

    International Nuclear Information System (INIS)

    Koca, Atif; Ceyhan, Tanju; Erbil, Mehmet K.; Ozkaya, Ali Riza; Bekaroglu, Ozer

    2007-01-01

    In this study, electrochemical, electrochromic and spectroelectrochemical properties of a tert-butylcalix[4]arene bridged bis double-decker lutetium(III) phthalocyanine (Lu 2 Pc 4 2) were investigated explicitly as compared with a tert-butylcalix[4]arene bridged dimeric lutetium(III) phthalocyanine [Lu 2 Pc 2 (OAc) 2 1]. Distinctive differences between electrochemical and electrochromic properties of 1 and 2 were detected. Moreover, the properties of 1 and 2 were compared with previously reported S 4 (CH 2 ) 4 bridged Lu 2 Pc 2 (OAc) 2 and Lu 2 Pc 4 . The calixarene bridged phthalocyanine (Pc) compounds, 1 and 2 showed well-defined electrochromic behaviour with green-blue and blue-purple colour transitions. The enhanced electrochromic properties of 2, as compared to 1, were attributed to its double-decker structure, probably allowing the formation of suitable ion channels for the counter ion movement in the solid film

  2. An Introduction To PC-TRIM.

    Science.gov (United States)

    John R. Mills

    1989-01-01

    The timber resource inventory model (TRIM) has been adapted to run on person al computers. The personal computer version of TRIM (PC-TRIM) is more widely used than its mainframe parent. Errors that existed in previous versions of TRIM have been corrected. Information is presented to help users with program input and output management in the DOS environment, to...

  3. Relationship between PC index and magnetospheric field-aligned currents measured by Swarm satellites

    DEFF Research Database (Denmark)

    Troshichev, О.; Sormakov, D.; Behlke, R.

    2018-01-01

    Abstract The relationship between the magnetospheric field-aligned currents (FAC) monitored by the Swarm satellites and the magnetic activity PC index (which is a proxy of the solar wind energy incoming into the magnetosphere) is examined. It is shown that current intensities measured in the R1...... between the PC index and the intensity of field-aligned currents in the R1 dawn and dusk layers: increase of FAC intensity in the course of substorm development is accompanied by increasing the PC index values. Correlation between PC and FAC intensities in the R2 dawn and dusk layers is also observed...

  4. Colombian reference growth curves for height, weight, body mass index and head circumference.

    Science.gov (United States)

    Durán, Paola; Merker, Andrea; Briceño, Germán; Colón, Eugenia; Line, Dionne; Abad, Verónica; Del Toro, Kenny; Chahín, Silvia; Matallana, Audrey Mary; Lema, Adriana; Llano, Mauricio; Céspedes, Jaime; Hagenäs, Lars

    2016-03-01

    Published Growth studies from Latin America are limited to growth references from Argentina and Venezuela. The aim of this study was to construct reference growth curves for height, weight, body mass index (BMI) and head circumference of Colombian children in a format that is useful for following the growth of the individual child and as a tool for public health. Prospective measurements from 27 209 Colombian children from middle and upper socio-economic level families were processed using the generalised additive models for location, scale and shape (GAMLSS). Descriptive statistics for length and height, weight, BMI and head circumference for age are given as raw and smoothed values. Final height was 172.3 cm for boys and 159.4 cm for girls. Weight at 18 years of age was 64.0 kg for boys and 54 kg for girls. Growth curves are presented in a ± 3 SD format using logarithmic axes. The constructed reference growth curves are a start for following secular trends in Colombia and are also in the presented layout an optimal clinical tool for health care. ©2015 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  5. Comparison of Relative Waist Circumference between Asian Indian and US Adults

    Directory of Open Access Journals (Sweden)

    Harpreet S. Bajaj

    2014-01-01

    Full Text Available Background. Relative to Europeans, Asian Indians have higher rates of type 2 diabetes and cardiovascular disease. Whether differences in body composition may underlie these population differences remains unclear. Methods. We compared directly measured anthropometric data from the Chennai Urban Rural Epidemiology Study (CURES survey of southern Indians (I with those from three US ethnic groups (C: Caucasians, A: African Americans, and M: Mexican Americans from NHANES III (Third National Health and Nutrition Examination Survey. A total of 15,733 subjects from CURES and 5,975 from NHANES III met inclusion criteria (age 20–39, no known diabetes. Results. Asian Indian men and women had substantially lower body mass index, waist circumference, hip circumference, waist-to-hip ratio, and body surface area relative to US groups (P values <0.0001. In contrast, the mean (±se waist-weight ratio was significantly higher (P<0.001 in I (men 1.35 ± 0.002 and women 1.45 ± 0.002 than in all the US groups (1.09, 1.21, and 1.14 in A, M, and C men; 1.23, 1.33, and 1.26 in A, M, and C women (se ranged from 0.005 to 0.006. Conclusions. Compared to the US, the waist-weight ratio is significantly higher in men and women from Chennai, India. These results support the hypothesis that Southeast Asian Indians are particularly predisposed toward central adiposity.

  6. Mutations in the G6PC3 gene cause Dursun syndrome.

    Science.gov (United States)

    Banka, Siddharth; Newman, William G; Ozgül, R Koksal; Dursun, Ali

    2010-10-01

    Dursun syndrome is a triad of familial primary pulmonary hypertension, leucopenia, and atrial septal defect. Here we demonstrate that mutations in G6PC3 cause Dursun syndrome. Mutations in G6PC3 are known to also cause severe congenital neutropenia type 4. Identification of the genetic basis of Dursun syndrome expands the pre-existing knowledge about the phenotypic effects of mutations in G6PC3. We propose that Dursun syndrome should now be considered as a subset of severe congenital neutropenia type 4 with pulmonary hypertension as an important clinical feature. Copyright © 2010 Wiley-Liss, Inc.

  7. An Automation Interface for Kappa PC

    DEFF Research Database (Denmark)

    Hartvig, Susanne C

    1999-01-01

    The reports documents an automation interface for Kappa PC. The automation interface can be used to embed Kappa applications in 32-bit Windowsapplications.The interface includes functions for initialising Kappa, for loading an application, for settingvalues, for getting values, and for stopping...

  8. ISO-PC Version 1.98: User`s guide

    Energy Technology Data Exchange (ETDEWEB)

    Rittmann, P.D.

    1995-05-02

    This document describes how to use Version 1.98 of the shielding program named ISO-PC. Version 1.98 corrects all known errors in ISOSHLD-II. In addition, a few numeric problems have been eliminated. There are three new namelist variables, 25 additional shielding materials, and 5 more energy groups. The two major differences with the original ISOSHLD-II are the removal of RIBD(radioisotope buildup and decay) source generator, and the removal of the non-uniform source distribution parameter, SSV1. This version of ISO-PC works with photon energies from 10 KeV to 10 MeV using 30 energy groups.

  9. The relationship of violence and traumatic stress to changes in weight and waist circumference: longitudinal analyses from the study of women's health across the nation.

    Science.gov (United States)

    Garcia, Lorena; Qi, Lihong; Rasor, Marianne; Clark, Cari Jo; Bromberger, Joyce; Gold, Ellen B

    2014-05-01

    This article investigates the associations of violence and traumatic stress with changes in weight and waist circumference, hypothesizing that violence in midlife would be associated with increases or decreases in weight and waist circumference. The longitudinal cohort of the Study of Women's Health Across the Nation comprised the study sample, which included an ethnically/racially and socially diverse group of 2,870 women between the ages of 42 and 52 years at baseline. Women were followed annually for 10 years, and assessments included weight and waist circumference measures and data on violence, health outcomes, and confounders. At baseline, 8.6% Caucasian, 10.8% African American, 9.2% Chinese, and 5.0% Japanese women reported violence and traumatic stress. Reporting violence and traumatic stress during follow-up was significantly associated with weight gain (odds ratio [OR] = 2.39, 95% confidence interval [CI] = [1.28-4.47]), weight loss (OR = 3.54, 95% CI = [1.73-7.22]), and gain (OR = 2.44, 95% CI = [1.37-4.37]) or loss (OR = 2.66, 95% CI = [1.23-5.77]) in waist circumference, adjusting for age, race/ethnicity, education, marital status, and smoking. Violence and traumatic stress against midlife women were associated with gains or losses in weight and waist circumference.

  10. Efficient Techniques for Formal Verification of PowerPC 750 Executables, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We will develop an efficient tool for formal verification of PowerPC 750 executables. The PowerPC 750 architecture is used in the radiation-hardened RAD750...

  11. Changes in waist circumference and the incidence of diabetes in middle-aged men and women

    DEFF Research Database (Denmark)

    Berentzen, Tina Landsvig; Jakobsen, Marianne Uhre; Halkjaer, Jytte

    2011-01-01

    Waist circumference (WC) is positively associated with diabetes, but the association with changes in WC (DWC) is less clear. We investigated the association between DWC and the subsequent risk of diabetes in middle-aged men and women, and evaluated the influence from concurrent changes in body mass...

  12. Determination of critical epitope of PcMab-47 against human podocalyxin

    Directory of Open Access Journals (Sweden)

    Shunsuke Itai

    2018-07-01

    Full Text Available Podocalyxin (PODXL is a type I transmembrane protein, which is highly glycosylated. PODXL is expressed in some types of human cancer tissues including oral, breast, and lung cancer tissues and may promote tumor growth, invasion, and metastasis. We previously produced PcMab-47, a novel anti-PODXL monoclonal antibody (mAb which reacts with endogenous PODXL-expressing cancer cell lines and normal cells independently of glycosylation in Western blot, flow cytometry, and immunohistochemical analysis. In this study, we used enzyme-linked immunosorbent assay (ELISA, flow cytometry, and immunohistochemical analysis to determine the epitope of PcMab-47. The minimum epitope of PcMab-47 was found to be Asp207, His208, Leu209, and Met210. A blocking peptide containing this minimum epitope completely neutralized PcMab-47 reaction against oral cancer cells by flow cytometry and immunohistochemical analysis. These findings could lead to the production of more functional anti-PODXL mAbs, which are advantageous for antitumor activities.

  13. Determination of critical epitope of PcMab-47 against human podocalyxin.

    Science.gov (United States)

    Itai, Shunsuke; Yamada, Shinji; Kaneko, Mika K; Kato, Yukinari

    2018-07-01

    Podocalyxin (PODXL) is a type I transmembrane protein, which is highly glycosylated. PODXL is expressed in some types of human cancer tissues including oral, breast, and lung cancer tissues and may promote tumor growth, invasion, and metastasis. We previously produced PcMab-47, a novel anti-PODXL monoclonal antibody (mAb) which reacts with endogenous PODXL-expressing cancer cell lines and normal cells independently of glycosylation in Western blot, flow cytometry, and immunohistochemical analysis. In this study, we used enzyme-linked immunosorbent assay (ELISA), flow cytometry, and immunohistochemical analysis to determine the epitope of PcMab-47. The minimum epitope of PcMab-47 was found to be Asp207, His208, Leu209, and Met210. A blocking peptide containing this minimum epitope completely neutralized PcMab-47 reaction against oral cancer cells by flow cytometry and immunohistochemical analysis. These findings could lead to the production of more functional anti-PODXL mAbs, which are advantageous for antitumor activities.

  14. PC communication world and Yiyagi 5.3

    International Nuclear Information System (INIS)

    1992-11-01

    This book is comprised of four parts about Yiyagi 5.3. It describes how to use Yiyagi 5.3 : the way to save 5.3 into floppy disk and Hard disk, to store modem, how to communicate with Hitel and PC-serve in the first part, how to use the various function : function key, control key, alt key, text editor of Yiyagi 5.3 and mouse in the second part, to be good at using communication : Modem, screen control, RS-232C and Null Modem, script and Multitasking in the third part. It has an appendix about compression and decompression of file, BBS list, PC application such as VGA graphic, UNIX/ XENIX and DOS, RS-232C and Modem and GR.exe.

  15. Glycated hemoglobin HbA1c, waist circumference, and waist-to-height ratio in overweight and obese adolescents

    Directory of Open Access Journals (Sweden)

    Elysa Nur Safrida

    2017-04-01

    Full Text Available Background Central obesity has been associated with a high risk of insulin resistance. Waist circumference and waist-to-height ratio are anthropometric indices for determining central obesity and have been associated with increased blood pressure, cholesterol, and insulin levels. In adults, fat distribution around the waist is a valid predictor of glycated hemoglobin (HbA1clevels, and is currently recommended by experts as a diagnostic tool for diabetes. Central obesity measurement has advantages over fasting blood glucose and oral glucose tolerance tests, as it is simple and inexpensive to perform. Objective To assess for correlations between HbA1c level and waist circumference as well as waist-to-height ratio and to assess factors potentially associated with HbA1c levels in overweight and obese adolescents. Methods This cross-sectional study was done in four junior high schools in Yogyakarta, which were obtained by cluster sampling. Overweight and obese students who were generally healthy were included in the study. Subjects underwent waist circumference and waist-to-height ratio measurements, as well as blood tests for HbA1clevels. Results Sixty-seven children participated in the study, with 48 girls (71.6% and 19 boys (28.4%. Waist circumference and HbA1c levels were not significantly associated (r=0.178; P=0.15. However, waist-to-height ratio and HbA1c levels had a weak positive correlation (r=0.21; P=0.04. Linear regression analysis revealed that waist-to-height ratio had a significant association with HbA1c level (P=0.02, but age, sex, and nutritional status did not. Conclusion Waist-to-height ratio is correlated with HbA1c levels in overweight and obese adolescents.

  16. Secular and race/ethnic trends in glycemic outcomes by BMI in US adults: The role of waist circumference.

    Science.gov (United States)

    Albrecht, Sandra S; Mayer-Davis, Elizabeth; Popkin, Barry M

    2017-07-01

    For the same body mass index (BMI) level, waist circumference (WC) is higher in more recent years. How this impacts diabetes and prediabetes prevalence in the United States and for different race/ethnic groups is unknown. We examined prevalence differences in diabetes and prediabetes by BMI over time, investigated whether estimates were attenuated after adjusting for waist circumference, and evaluated implications of these patterns on race/ethnic disparities in glycemic outcomes. Data came from 12 614 participants aged 20 to 74 years from the National Health and Nutrition Examination Surveys (1988-1994 and 2007-2012). We estimated prevalence differences in diabetes and prediabetes by BMI over time in multivariable models. Relevant interactions evaluated race/ethnic differences. Among normal, overweight, and class I obese individuals, there were no significant differences in diabetes prevalence over time. However, among individuals with class II/III obesity, diabetes prevalence rose 7.6 percentage points in 2007-2012 vs 1988-1994. This estimate was partly attenuated after adjustment for mean waist circumference but not mean BMI. For prediabetes, prevalence was 10 to 13 percentage points higher over time at lower BMI values, with minimal attenuation after adjustment for WC. All patterns held within race/ethnic groups. Diabetes disparities among blacks and Mexican Americans relative to whites remained in both periods, regardless of BMI, and persisted after adjustment for WC. Diabetes prevalence rose over time among individuals with class II/III obesity and may be partly due to increasing waist circumference. Anthropometric measures did not appear to account for temporal increases in prediabetes, nor did they attenuate race/ethnic disparities in diabetes. Reasons underlying these trends require further investigation. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Weight-adjusted lean body mass and calf circumference are protective against obesity-associated insulin resistance and metabolic abnormalities.

    Science.gov (United States)

    Takamura, Toshinari; Kita, Yuki; Nakagen, Masatoshi; Sakurai, Masaru; Isobe, Yuki; Takeshita, Yumie; Kawai, Kohzo; Urabe, Takeshi; Kaneko, Shuichi

    2017-07-01

    To test the hypothesis that preserved muscle mass is protective against obesity-associated insulin resistance and metabolic abnormalities, we analyzed the relationship of lean body mass and computed tomography-assessed sectional areas of specific skeletal muscles with insulin resistance and metabolic abnormalities in a healthy cohort. A total of 195 subjects without diabetes who had completed a medical examination were included in this study. Various anthropometric indices such as circumferences of the arm, waist, hip, thigh, and calf were measured. Body composition (fat and lean body mass) was determined by bioelectrical impedance analysis. Sectional areas of specific skeletal muscles (iliopsoas, erector spinae, gluteus, femoris, and rectus abdominis muscles) were measured using computed tomography. Fat and lean body mass were significantly correlated with metabolic abnormalities and insulin resistance indices. When adjusted by weight, relationships of fat and lean body mass with metabolic parameters were mirror images of each other. The weight-adjusted lean body mass negatively correlated with systolic and diastolic blood pressures; fasting plasma glucose, HbA1c, alanine aminotransferase, and triglyceride, and insulin levels; and hepatic insulin resistance indices, and positively correlated with HDL-cholesterol levels and muscle insulin sensitivity indices. Compared with weight-adjusted lean body mass, weight-adjusted sectional areas of specific skeletal muscles showed similar, but not as strong, correlations with metabolic parameters. Among anthropometric measures, the calf circumference best reflected lean body mass, and weight-adjusted calf circumference negatively correlated with metabolic abnormalities and insulin resistance indices. Weight-adjusted lean body mass and skeletal muscle area are protective against weight-associated insulin resistance and metabolic abnormalities. The calf circumference reflects lean body mass and may be useful as a protective

  18. Limb-bud and Heart Overexpression Inhibits the Proliferation and Migration of PC3M Cells.

    Science.gov (United States)

    Liu, Qicai; Li, Ermao; Huang, Long; Cheng, Minsheng; Li, Li

    2018-01-01

    Background: The limb-bud and heart gene ( LBH ) was discovered in the early 21st century and is specifically expressed in the mouse embryonic limb and heart development. Increasing evidences have indicated that LBH not only plays an important role in embryo development, it is also closely correlated with the occurance and progression of many tumors. However, its function in prostate cancer (PCa) is still not well understood. Here, we explored the effects of LBH on the proliferation and migration of the PCa cell line PC3M. Methods: LBH expression in tissues and cell lines of PCa was detected by immunohistochemistry and Western blotting. Lentivirus was used to transduct the LBH gene into the PC3M cells. Stable LBH-overexpressing PC3M-LBH cells and PC3M-NC control cells were obtained via puromycin screening. Cell proliferation was examined using the 3-(4,5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide (MTT) assay. Cell cycle distribution and apoptosis rate were investigated using flow cytometry. Cell migration was studied using the Transwell assay. Results: LBH expression level was down-regulated in 3 different PCa cell lines, especially in PC3M cells, compared with the normal prostate epithelial cells(RWPE-1). Cell lines of LBH-upregulated PC3M-LBH and PC3M-NC control were successfully constructed. Significantly increased LBH expression level and decreased cyclin D1 and cyclin E2 expression level was found in PC3M-LBH cells as compared to the PC3M-NC cells. The overexpression of LBH significantly inhibited PC3M cell proliferation in vitro and tumor growth in nude mice. LBH overexpression in PC3M cell, also induced cell cycle G0/G1 phase arrest and decreased the migration of PC3M cells. Conclusions : Our results reveal that LBH expression is down-regulated in the tissue and cell lines of PCa. LBH overexpression inhibits PC3M cell proliferation and tumor growth by inducing cell cycle arrest through down-regulating cyclin D1and cyclin E2 expression. LBH might

  19. Isoform 1 of TPD52 (PC-1) promotes neuroendocrine transdifferentiation in prostate cancer cells

    KAUST Repository

    Moritz, Tom

    2016-02-05

    The tumour protein D52 isoform 1 (PC-1), a member of the tumour protein D52 (TPD52) protein family, is androgen-regulated and prostate-specific expressed. Previous studies confirmed that PC-1 contributes to malignant progression in prostate cancer with an important role in castration-resistant stage. In the present work, we identified its impact in mechanisms leading to neuroendocrine (NE) transdifferentiation. We established for long-term PC-1 overexpression an inducible expression system derived from the prostate carcinoma cell line LNCaP. We observed that PC-1 overexpression itself initiates characteristics of neuroendocrine cells, but the effect was much more pronounced in the presence of the cytokine interleukin-6 (IL-6). Moreover, to our knowledge, this is the first report that treatment with IL-6 leads to a significant upregulation of PC-1 in LNCaP cells. Other TPD52 isoforms were not affected. Proceeding from this result, we conclude that PC-1 overexpression enhances the IL-6-mediated differentiation of LNCaP cells into a NE-like phenotype, noticeable by morphological changes and increased expression of typical NE markers, like chromogranin A, synaptophysin or beta-3 tubulin. Immunofluorescent staining of IL-6-treated PC-1-overexpressing LNCaP cells indicates a considerable PC-1 accumulation at the end of the long-branched neuron-like cell processes, which are typically formed by NE cells. Additionally, the experimentally initiated NE transdifferentiation correlates with the androgen receptor status, which was upregulated additively. In summary, our data provide evidence for an involvement of PC-1 in NE transdifferentiation, frequently associated with castration resistance, which is a major therapeutic challenge in the treatment of advanced prostate cancer.

  20. PC based alpha, beta and gamma counting system

    International Nuclear Information System (INIS)

    Bhattacharya, S.; Gopalakrishnan, K.R.; Bairi, B.R.

    1992-01-01

    In the field of radiation protection and safety a large number of samples have to be assayed for estimation of their radioactivity at various stages in nuclear fuel. A PC based alpha, beta and gamma counting system has been designed for the above application. The system is fully automatic and requires minimum of operator intervention. The main units in the system are detector and pulse processing electronics, sample changer and assembly and IBM PC interface and supporting software. The main function of interface is to control the sample changer which is basically loading and unloading of sample, data acquisition and further processing by software. The pulses from detector are analysed in a pulse shape discriminator. A pulse identified as an alpha, beta or gamma event is converted to digital pulse. These digital pulses are accumulated in the three channels on PC interface each corresponding to alpha, beta and gamma. The sample movements are controlled by interface depending upon sample position. The software has been developed so as to maintain user friendliness and convenience of the operator. Various selection modes for parameters and operation of system provide lot of flexibility in operation of the system. (author). 1 fig

  1. Tablet PC interaction with digital micromirror device (DMD)

    Science.gov (United States)

    Refai, Hakki H.; Dahshan, Mostafa H.; Sluss, James J., Jr.

    2007-02-01

    Digital light processing (DLP) is an innovative display technology that uses an optical switch array, known as a digital micromirror device (DMD), which allows digital control of light. To date, DMDs have been used primarily as high-speed spatial light modulators for projector applications. A tablet PC is a notebook or slate-shaped mobile PC. Its touch screen or digitizing tablet technology allows the user to operate the notebook with a stylus or digital pen instead of using a keyboard or mouse. In this paper, we describe an interface solution that translates any sketch on the tablet PC screen to an identical mirror-copy over the cross-section of the DMD micromirrors such that the image of the sketch can be projected onto a special screen. An algorithm has been created to control each single micromirror of the hundreds of thousands of micromirrors that cover the DMD surface. We demonstrate the successful application of a DMD to a high-speed two-dimensional (2D) scanning environment, acquiring the data from the tablet screen and launching its contents to the projection screen; with very high accuracy up to 13.68 μm x 13.68 μm of mirror pitch.

  2. A PC based 8K multichannel analyzer [Paper No.: I2

    International Nuclear Information System (INIS)

    Bahere, A.R.; Vaidya, P.P.; Tabib, J.D.; Jha, Kuldip

    1993-01-01

    This paper describes a PC add on MCA card for nuclear spectroscopy applications. It consists of a 8K nuclear ADC, control logic and 8K * 24 bit dual ported histogram memory. The integral card assembly plugs into a single I/O expansion slot of the IBM-PC XT/AT or any compatible PC. This together with the data acquisition and processing software package, developed in Turbo C transforms the PC into a powerful Multichannel Analyzer. In the design of the MCA card, the PC interface, sequencers and control logic is implemented using programmable logic devices in order to achieve compact, efficient and reliable design. The dual ported 8K * 24 bit histogram memory is implemented using conventional static memory with external arbitration logic. Built-in ADC is designed around commercially available monolithic successive approximation type ADC chip. The low differential nonlinearity is achieved using an innovative interpolation technique along with Gatti sliding technique. The data acquisition and processing package developed in Turbo C, includes interrupt driven spectrum display driver and a pull down menu based user interface. Data processing features include spectrum smoothing, auto peak search and energy calibration. Separate memory buffers are used for data acquisition and data processing. Thus it is possible to acquire data in the background while analyzing an earlier acquired data. (author). 2 refs., 4 figs

  3. No evidence that polymorphisms of brain regulator genes Microcephalin and ASPM are associated with general mental ability, head circumference or altruism.

    Science.gov (United States)

    Rushton, J Philippe; Vernon, Philip A; Bons, Trudy Ann

    2007-04-22

    We test the hypothesis that polymorphisms of the brain regulator genes MCPH1 and ASPM contribute to variations in human brain size and its correlates. We measured general mental ability, head circumference and social intelligence in 644 Canadian adults (496 Caucasians, 36 Orientals, 84 Mixed Race/Other and 28 Blacks; 257 men and 387 women). The gene polymorphisms were assessed from buccal DNA; mental ability by Wonderlic Personnel Test and Multidimensional Aptitude Battery; head circumference by stretchless tape; and social intelligence by prosocial attitude questionnaires. Although all measures were construct valid and the allele frequencies showed expected population differences, no relationship was found between the genes and any of the criteria. Among Caucasian 18-25 year olds, for example, the two mental ability tests correlated with each other (r=0.78, N=476, p<0.001), with head circumference (r=0.17, N=182, p<0.05) and with prosocial attitudes (r=0.23, N=182, p<0.001).

  4. Data Communication PC/NaI-borehole probe (Hardware & Software)

    DEFF Research Database (Denmark)

    Madsen, Peter Buch

    Development of new hard- & software to a NaI borehole probe on a PC. Save data from the probe each 10'th sec, handle the data from the probe and make calculations every 10'th sec and show the results on the monitor.......Development of new hard- & software to a NaI borehole probe on a PC. Save data from the probe each 10'th sec, handle the data from the probe and make calculations every 10'th sec and show the results on the monitor....

  5. PC-based digital feedback control for scanning force microscope

    International Nuclear Information System (INIS)

    Mohd Ashhar Khalid

    2002-01-01

    In the past, most digital feedback implementation for scanned-probe microscope were based on a digital signal processor (DSP). At present DSP plug-in card with the input-output interface module is still expensive compared to a fast pentium PC motherboard. For a magnetic force microscope (MFM) digital feedback has an advantage where the magnetic signal can be easily separated from the topographic signal. In this paper, a simple low-cost PC-based digital feedback and imaging system for Scanning Force Microscope (SFM) is presented. (Author)

  6. PC add on card for processing of LSC signals

    International Nuclear Information System (INIS)

    Jadhav, S.R.; Nikhare, D.M.; Gurna, R.K.; Paulson, Molly; Kulkarni, C.P.; Vaidya, P.P.

    2001-01-01

    This paper describes PC- add on card developed at Electronics Division for processing of LSC signals. This card uses highly integrated digital and analog circuits, for entire processing of signals available from preamplifiers to get complete beta energy spectrum corresponding to coincident events in Liquid Scintillation Counting. LSC card along with High Voltage PC-add on card gives complete electronics required for LSC system. This card is also used in automatic LSC system along with interface circuits, which are used to control mechanical movements. (author)

  7. CC-3 CAMAC crate controller for IBM PC

    International Nuclear Information System (INIS)

    Khare, A.N.; Ghodgaonkar, M.D.; Bairi, B.R.

    1991-01-01

    The specifications and implementation details of CAMAC Crate Controller CC-3 for IBM-PC compatible as a host computer, having capability to transfer high speed data with direct memory access (DMA) scheme and logic to execute CAMAC cycles directly from the crate controller, to implement the block algorithms specified in ANSI/IEEE Std. 683-1976 (Reaff-1981) are described. The maximum data transfer rate measured with 8 bit interface of PC-AT is 240K byte per second. This work is carried out under Seventh Five Year Plan Project on Modernisation of reactor Control Instrumentation and Development of CAMAC and Fastbus Instrumentation. (author). 9 refs., 5 figs., 4 appendixes

  8. State of the art of parallel scientific visualization applications on PC clusters

    International Nuclear Information System (INIS)

    Juliachs, M.

    2004-01-01

    In this state of the art on parallel scientific visualization applications on PC clusters, we deal with both surface and volume rendering approaches. We first analyze available PC cluster configurations and existing parallel rendering software components for parallel graphics rendering. CEA/DIF has been studying cluster visualization since 2001. This report is part of a study to set up a new visualization research platform. This platform consisting of an eight-node PC cluster under Linux and a tiled display was installed in collaboration with Versailles-Saint-Quentin University in August 2003. (author)

  9. Validity of mid arm circumference to detect protein energy malnutrition among 8-11 months old infants in a rural medical college of West Bengal.

    Science.gov (United States)

    Sadhukhan, Sanjoy Kr; Chatterjee, Chitra; Shrivastava, Prabha; Sardar, Jadav Chandra; Joardar, Gautam Kr; Lahiri, Saibendu

    2010-09-01

    This institution-based cross-sectional observational validation study was conducted in the immunisation clinic of North Bengal Medical College and Hospital, Sushrutanagar. The objective was to identify the validity characteristics of mid arm circumference to detect protein energy malnutrition among 8-11 months infants and to find out a suitable cut-off value if any. Study variables were age, sex, body weight and mid arm circumference. Mid arm circumference was validated against weight for age criteria (gold standard) of malnutrition. The mean mid arm circumference of the infants was found to be almost constant with only about 2.22% change over 4 months, signifying that single cut-off point can be used to detect protein energy malnutrition. Mid arm circumference values from 13.0 to 12.5 cm were found to have the highest accuracy to detect protein energy malnutrition (about 86%). The cut-off values of 12.5 and 12.6 cm were noted to have a sensitivity and specificity of about 52% and 96% respectively, a false negativity of 48% but a false positivity of only 4%. Receiver operating characteristics curve detected 12.5(12.6) cm as the best diagnostic cut-off point which can detect more than 50% of the malnourished babies with very little false positivity/misdiagnosis (only 4%). A simple measuring tape with some reorientation of the health workers can detect the beginning of childhood malnutrition.

  10. [Synthesis of a supermolecular nanoparticle γ-hy-PC/Ada-Dox and its antitumor activity].

    Science.gov (United States)

    Li, Yong-bin; Wang, Kai; Hu, Tian-nan; Wang, Qi-wen; Hu, Qi-da; Zhou, Jun; Hu, Xiu-rong; Tang, Gu-ping

    2012-11-01

    To synthesize a (2-Hydroxypropyl)-γ-cyclodextrin-polyethylenimine/adamantane-conjugated doxorubicin (γ-hy-PC/Ada-Dox) based supramolecular nanoparticle with host-guest interaction and to identify its physicochemical characterizations and antitumor effect. A novel non-viral gene delivery vector γ-hy-PC/Ada-Dox was synthesized based on host-guest interaction. 1H-NMR, NOESY, UV-Vis, XRD and TGA were used to confirm the structure of the vector. The DNA condensing ability of complexes was investigated by particle size, zeta potential and gel retardation assay. Cytotoxicity of complexes was determined by MTT assay in BEL-7402 and SMMC-7721 cells. Cell wound healing assay was performed in HEK293 and BEL-7404 cells. The transfection efficiency was investigated in HEK293 cells. H/E staining and cell uptake assay was performed in BEL-7402 cells. The structure of γ-hy-PC/Ada-Dox was characterized by 1H-NMR, NOESY, UV-Vis, XRD, TGA. The drug loading was 0.5% and 5.5%. Gel retardation assay showed that γ-hy-PC was able to completely condense DNA at N/P ratio of 2; 0.5% and 5.5% γ-hy-PC/Ada-Dox was able to completely condense DNA at N/P ratio of 3 and 4,respectively. The cytotoxicity of polymers was lower than that of PEI25KDa. The transfection efficiency of γ-hy-PC was higher than that of γ-hy-PC/Ada-Dox at N/P ratio of 30 in HEK293 cells; and the transfection efficiency was decreasing when Ada-Dox loading was increasing. Cell uptake assay showed that γ-hy-PC/Ada-Dox was able to carry drug and FAM-siRNA into cells. The novel vector γ-hy-PC/Ada-Dox has been developed successfully, which has certain transfection efficiency and antitumor activity.

  11. Does change in hip circumference predict cardiovascular disease and overall mortality in Danish and Swedish women?

    DEFF Research Database (Denmark)

    Lanfer, Anne; Mehlig, Kirsten; Heitmann, Berit L

    2014-01-01

    Accumulating evidence consistently shows that small hip circumference (HC) is related to increased risk of cardiovascular disease (CVD), coronary heart disease, diabetes, and premature death in women. This study aims to clarify whether this inverse association can be found in both normal...

  12. Morphological, structural and optical properties of MEH-PPV: PC70BM nanocomposite film

    Science.gov (United States)

    Mhamdi, Asya; Sweii, Fatma ben Slama; Saidi, Hamza; Saidi, Faouzi; Bouazizi, Abdelaziz

    2018-05-01

    In this report, the influence of annealing temperature and spin coating speed on the structural and morphological properties of a blend of poly (2-methoxy-5-(2-ethyl-oxy)-p-phenylene-vinylene) (MEH-PPV) and [6-6]-phenyl-C71-butyric acid methyl ester (PC70BM) layer has been investigated. The photoactive layer (MEH-PPV: PC70BM) was deposited on ZnO film deposited on top of indium tin oxide (ITO) substrate by spin-coating. The effect of spin coating speed via atomic force microscope (AFM) leads to conclude that high speed is favorable for a good homogeneity of the film surface and good aggregates dispersion. The optimized structure was studied by varying the annealing temperatures using X-ray diffraction (XRD). The XRD analysis indicates that annealing treatment promoted the ordered aggregation and crystallization of MEH-PPV: PC70BM films. Indeed, the blend ratio effect on the optical properties of MEH-PPV: PC70BM thin film was investigated. While, the effect of incorporation of PC70BM on the optical properties was studied using UV-Vis and photoluminescence (PL) measurement. We conclude that MEH-PPV: PC70BM (1:3) film leads to high charge transfer rate.

  13. Compartment-Specific Biosensors Reveal a Complementary Subcellular Distribution of Bioactive Furin and PC7

    Directory of Open Access Journals (Sweden)

    Pierpaolo Ginefra

    2018-02-01

    Full Text Available Furin trafficking, and that of related proprotein convertases (PCs, may regulate which substrates are accessible for endoproteolysis, but tools to directly test this hypothesis have been lacking. Here, we develop targeted biosensors that indicate Furin activity in endosomes is 10-fold less inhibited by decanoyl-RVKR-chloromethylketone and enriched >3-fold in endosomes compared to the trans-Golgi network (TGN. Endogenous PC7, which resists this inhibitor, was active in distinct vesicles. Only overexpressed PC7 activity reached the cell surface, endosomes, and the TGN. A PLC motif in the cytosolic tail of PC7 was dispensable for endosomal activity, but it was specifically required for TGN recycling and to rescue proActivin-A cleavage in Furin-depleted B16F1 melanoma cells. In sharp contrast, PC7 complemented Furin in cleaving Notch1 independently of PLC-mediated TGN access. Our study provides a proof in principle that compartment-specific biosensors can be used to gain insight into the regulation of PC trafficking and to map the tropism of PC-specific inhibitors.

  14. Construction and identification of eukaryotic expression vector of pcDNA3-UHRF1

    International Nuclear Information System (INIS)

    Li Xinli; Zhu Ran; Zhu Wei; Fan Saijun; Meng Qinghui

    2011-01-01

    Objective: To generate eukaryotic expression vector of pcDNA3-UHRF1(ubiquitin-like, containing PHD and RING finger domains 1, UHRF1) and testify its expression in breast cancer cells MDA-MB-231. Methods: A 2.3 kb cDNA fragment was amplified from the total RNA of the human breast cancer cells MCF-7 by the RT-PCR method and was cloned into the plasmid pcDNA3. The vector was identified by the double digestion with restriction enzymes Kpn I and Xho I and was sequenced. The cDNA of UHRF1 was transfected into human breast cancer cells MDA-MB-231 by Lipofactamin2000. The positive clones were selected by G418. The expression of the UHRF1 was detected by RT-PCR and Western blot analysis. Results: The recombinant eukaryotic expression vector pcDNA3-UHRF1 was digested with Kpn I and BamH I, and the electrophoresis of the digested products showed two fragments; 2.3kb fragment of UHRF1 and 5.4 kb fragment of pcDNA3, and the sequence inserted was identical to the published sequence. The MDA-MB-231 cells transfected with the pcDNA3-UHRF1 plasmid expressed a high level of the UHRF1 mRNA and protein. Conclusion: The recombinant eukaryotic cell expression vector of pcDNA3-UHRF1 is constructed successfully. The recombinant plasmid pcDNA3-UHRF1 can provide a very useful tool and lay an important foundation for the research on the function of UHRF1. (authors)

  15. PC_Eyewitness and the sequential superiority effect: computer-based lineup administration.

    Science.gov (United States)

    MacLin, Otto H; Zimmerman, Laura A; Malpass, Roy S

    2005-06-01

    Computer technology has become an increasingly important tool for conducting eyewitness identifications. In the area of lineup identifications, computerized administration offers several advantages for researchers and law enforcement. PC_Eyewitness is designed specifically to administer lineups. To assess this new lineup technology, two studies were conducted in order to replicate the results of previous studies comparing simultaneous and sequential lineups. One hundred twenty university students participated in each experiment. Experiment 1 used traditional paper-and-pencil lineup administration methods to compare simultaneous to sequential lineups. Experiment 2 used PC_Eyewitness to administer simultaneous and sequential lineups. The results of these studies were compared to the meta-analytic results reported by N. Steblay, J. Dysart, S. Fulero, and R. C. L. Lindsay (2001). No differences were found between paper-and-pencil and PC_Eyewitness lineup administration methods. The core findings of the N. Steblay et al. (2001) meta-analysis were replicated by both administration procedures. These results show that computerized lineup administration using PC_Eyewitness is an effective means for gathering eyewitness identification data.

  16. User`s guide and documentation manual for ``PC-Gel`` simulator

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Ming-Ming; Gao, Hong W.

    1993-10-01

    PC-GEL is a three-dimensional, three-phase (oil, water, and gas) permeability modification simulator developed by incorporating an in-situ gelation model into a black oil simulator (BOAST) for personal computer application. The features included in the simulator are: transport of each chemical species of the polymer/crosslinker system in porous media, gelation reaction kinetics of the polymer with crosslinking agents, rheology of the polymer and gel, inaccessible pore volume to macromolecules, adsorption of chemical species on rock surfaces, retention of gel on the rock matrix, and permeability reduction caused by the adsorption of polymer and gel. The in-situ gelation model and simulator were validated against data reported in the literature. The simulator PC-GEL is useful for simulating and optimizing any combination of primary production, waterflooding, polymer flooding, and permeability modification treatments. A general background of permeability modification using crosslinked polymer gels is given in Section I and the governing equations, mechanisms, and numerical solutions of PC-GEL are given in Section II. Steps for preparing an input data file with reservoir and gel-chemical transport data, and recurrent data are described in Sections III and IV, respectively. Example data inputs are enclosed after explanations of each input line to help the user prepare data files. Major items of the output files are reviewed in Section V. Finally, three sample problems for running PC-GEL are described in Section VI, and input files and part of the output files of these problems are listed in the appendices. For the user`s reference a copy of the source code of PC-GEL computer program is attached in Appendix A.

  17. Induction of cytoprotective autophagy in PC-12 cells by cadmium

    International Nuclear Information System (INIS)

    Wang, Qiwen; Zhu, Jiaqiao; Zhang, Kangbao; Jiang, Chenyang; Wang, Yi; Yuan, Yan; Bian, Jianchun; Liu, Xuezhong; Gu, Jianhong; Liu, Zongping

    2013-01-01

    Highlights: •Cadmium can promote early upregulation of autophagy in PC-12 cells. •Autophagy precedes apoptosis in cadmium-treated PC-12 cells. •Cadmium-induced autophagy is cytoprotective in PC-12 cells. •Class III PI3K/beclin-1/Bcl-2 signaling pathway plays a positive role in cadmium-triggered autophagy. -- Abstract: Laboratory data have demonstrated that cadmium (Cd) may induce neuronal apoptosis. However, little is known about the role of autophagy in neurons. In this study, cell viability decreased in a dose- and time-dependent manner after treatment with Cd in PC-12 cells. As cells were exposed to Cd, the levels of LC3-II proteins became elevated, specific punctate distribution of endogenous LC3-II increased, and numerous autophagosomes appeared, which suggest that Cd induced a high level of autophagy. In the late stages of autophagy, an increase in the apoptosis ratio was observed. Likewise, pre-treatment with chloroquine (an autophagic inhibitor) and rapamycin (an autophagic inducer) resulted in an increased and decreased percentage of apoptosis in contrast to other Cd-treated groups, respectively. The results indicate that autophagy delayed apoptosis in Cd-treated PC-12 cells. Furthermore, co-treatment of cells with chloroquine reduced autophagy and cell activity. However, rapamycin had an opposite effect on autophagy and cell activity. Moreover, class III PI3 K/beclin-1/Bcl-2 signaling pathways served a function in Cd-induced autophagy. The findings suggest that Cd can induce cytoprotective autophagy by activating class III PI3 K/beclin-1/Bcl-2 signaling pathways. In sum, this study strongly suggests that autophagy may serve a positive function in the reduction of Cd-induced cytotoxicity

  18. Static and Dynamic Energetic Disorders in the C 60 , PC 61 BM, C 70 , and PC 71 BM Fullerenes

    KAUST Repository

    Tummala, Naga Rajesh

    2015-09-17

    We use a combination of molecular dynamics simulations and density functional theory calculations to investigate the energetic disorder in fullerene systems. We show that the energetic disorder evaluated from an ensemble average contains contributions of both static origin (time-independent, due to loose packing) and dynamic origin (time-dependent, due to electron-vibration interactions). In order to differentiate between these two contributions, we compare the results obtained from an ensemble average approach with those derived from a time average approach. It is found that in both amorphous C60 and C70 bulk systems, the degrees of static and dynamic disorder are comparable, while in the amorphous PC61BM and PC71BM systems, static disorder is about twice as large as dynamic disorder. © 2015 American Chemical Society.

  19. PC-based input/output controllers from a VME perspective

    International Nuclear Information System (INIS)

    Hill, J.O.

    1999-01-01

    The Experimental Physics and Industrial Control System (EPICS) has been widely adopted in the accelerator community. Although EPICS is available on many platforms, the majority of sites have deployed VME- or VXI-based input output controllers running the vxWorks real time operating system. Recently, a hybrid approach using vxWorks on both PC and traditional platforms is being implemented at LANL. To illustrate these developments the author compares his recent experience deploying PC-based EPICS input output controllers with experience deploying similar systems based on traditional EPICS platforms

  20. Effect of γ-radiation on glass transition temperature of Poly(Bisphenol A carbonate) (PC)

    International Nuclear Information System (INIS)

    Kalkar, A.K.; Kundagol, S.

    1988-01-01

    Thin films of pure Poly(Bisphenol A carbonate) (PC) were γ-irradiated at room temperature from Co 60 source for varied doses, for the systematic study of γ-radiation on glass transition temperature (Tsub(g)) of PC. It was found that Tsub(g) of PC decreases with increasing doses. Irradiation of γ-rays on PC results in evolution of CO, CO 2 and H 2 from carbonate linkage and methyl group and which results in lowering of average mol.wt. of bul k polymer. Hence, overall increase in free volume increases chain mobility and thus reduces the Tsub(g). (author)

  1. The design of PC/MISI, a PC-based common user interface to remote information storage and retrieval systems. Presentation visuals. M.S. Thesis Final Report, 1 Jul. 1985 - 31 Dec. 1987

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Hall, Philip P.

    1985-01-01

    This Working Paper Series entry represents a collection of presentation visuals associated with the companion report entitled, The Design of PC/MISI, a PC-Based Common User Interface to Remote Information Storage and Retrieval Systems, USL/DBMS NASA/RECON Working Paper Series report number DBMS.NASA/RECON-15. The paper discusses the following: problem definition; the PC solution; the goals of system design; the design description; future considerations, the research environment; conclusions.

  2. Head circumference in Iranian infants

    Directory of Open Access Journals (Sweden)

    Mohammad Esmaeili

    2015-03-01

    Full Text Available Introduction: Head circumference (HC measurement is one of the important parameter for diagnosis of neurological, developmental disorders and dysmorphic syndromes. Recognition of different disorders requires an understanding of normal variation for HC size, in particular, in infancy period with most rapid growth of the brain. Because of international and interracial standard chart differences about anthropometric indices, some differences from local to local, generation to generation and changes in ethnic mix of population and socioeconomic factors, periodic revolution of HC size is suggested. The aims of our study were presenting local HC standard for an Iranian infant population and comparison with the American national center of health statistics (NCHS charts accepted by WHO. Methods: 1003 subjects aged from birth to 24 months apparently healthy normal children enrolled randomly in this cross sectional study. HC size were measured and recorded. Tables and graphs were depicted by Excel Microsoft Office 2007. We use two tailed t-student test for statistical analysis. Results: The mean of HC size in boys was larger than girls. The curves were followed a similar pattern to NCHS based on a visual comparison. Overall our subjects in both sexes at birth time had smaller HC size than NCHS. In other ages our children had larger HC size than those of NCHS. Conclusion: Because of international and interracial difference of HC size. We recommend in each area of the world, local anthropometric indices are constructed and used clinically. In addition more extensive and longitudinally design comprehensive studies is suggested.

  3. Ala54Thr fatty acid-binding protein 2 (FABP2 polymorphism in recurrent depression: associations with fatty acid concentrations and waist circumference.

    Directory of Open Access Journals (Sweden)

    Roel J T Mocking

    Full Text Available BACKGROUND: Fatty acid (FA-alterations may mediate the mutual association between Major Depressive Disorder (MDD and cardiovascular disease (CVD. However, etiology of observed FA-alterations in MDD and CVD remains largely unclear. An interesting candidate may be a mutation in the fatty acid-binding protein 2 (FABP2-gene, because it regulates dietary FA-uptake. Therefore, we aimed to test the hypotheses that in MDD-patients the FABP2 Ala54Thr-polymorphism would be (I more prevalent than in sex- and age-matched controls, (II associated with observed alterations in FA-metabolism, and (III associated with CVD-risk factor waist circumference. METHODS: We measured concentrations of 29 different erythrocyte FAs, FABP2-genotype, and waist circumference in recurrent MDD-patients and matched never-depressed controls. RESULTS: FABP2-genotype distribution did not significantly differ between the 137 MDD-patients and 73 matched controls. However, patients with the Ala54Thr-polymorphism had (I higher concentrations of especially eicosadienoic acid (C20:2ω6; P=.009 and other 20-carbon FAs, and associated (II lower waist circumference (P=.019. In addition, FABP2-genotype effects on waist circumference in patients seemed (I mediated by its effect on C20:2ω6, and (II different from controls. CONCLUSIONS: Although Ala54Thr-polymorphism distribution was not associated with recurrent MDD, our results indicate that FABP2 may play a role in the explanation of observed FA-alterations in MDD. For Ala54Thr-polymorphism patients, potentially adaptive conversion of increased bioavailable dietary precursors into eicosadienoic acid instead of arachidonic acid might be related to a low waist circumference. Because this is the first investigation of these associations, replication is warranted, preferably by nutrigenetic studies applying lipidomics and detailed dietary assessment.

  4. ERES--a PC software for nuclear data compilation in EXFOR format

    International Nuclear Information System (INIS)

    Li Shubing; Liang Qichang; Liu Tingjin

    1993-01-01

    The major functions and implementation of the software ERES (EXFOR Edit System) are introduced. The ERES is developed for nuclear data compilation in EXFOR (EXchange FORmat) format, running on IBM-PC/XT or IBM-PC/AT. EXFOR is the format for the exchange of experimental neutron data accepted by four neutron data centers in the world

  5. Common variants at 12q15 and 12q24 are associated with infant head circumference

    NARCIS (Netherlands)

    H.R. Taal (Rob); B. St Pourcain (Beate); E. Thiering (Eelisabeth); S. Das (Shikta); D.O. Mook-Kanamori (Dennis); N.M. Warrington (Nicole); M. Kaakinen (Marika); E. Kreiner-Møller (Eskil); J.P. Bradfield (Jonathan); R.M. Freathy (Rachel); F. Geller (Frank); M. Guxens Junyent (Mònica); D.L. Cousminer (Diana); M. Kerkhof (Marjan); N.J. Timpson (Nicholas); M.A. Ikram (Arfan); L.J. Beilin (Lawrence); K. Bønnelykke (Klaus); J.L. Buxton (Jessica); P. Charoen (Pimphen); B.L.K. Chawes (Bo Lund Krogsgaard); J.G. Eriksson (Johan); D.M. Evans (David); A. Hofman (Albert); J.P. Kemp (John); C.E. Kim (Cecilia); N. Klopp (Norman); J. Lahti (Jari); S.J. Lye (Stephen); G. Mcmahon (George); F.D. Mentch (Frank); M. Müller-Nurasyid (Martina); P.F. O'Reilly (Paul); I. Prokopenko (Inga); F. Rivadeneira Ramirez (Fernando); E.A.P. Steegers (Eric); J. Sunyer (Jordi); C. Tiesler (Carla); H. Yaghootkar (Hanieh); M.M.B. Breteler (Monique); S. Debette (Stéphanie); M. Fornage (Myriam); V. Gudnason (Vilmunder); L.J. Launer (Lenore); A. van der Lugt (Aad); T.H. Mosley (Thomas); S. Seshadri (Sudha); A.V. Smith (Albert V.); M.W. Vernooij (Meike); A.I.F. Blakemore (Alexandra); R.M. Chiavacci (Rosetta); B. Feenstra (Bjarke); J. Fernandez-Banet (Julio); S.F.A. Grant (Struan); A.-L. Hartikainen (Anna-Liisa); A.J. van der Heijden (Albert); C. Iniguez (Carmen); M. Lathrop (Mark); W.L. McArdle (Wendy); A. Mølgaard (Anne); J.P. Newnham (John); L.J. Palmer (Lyle); A. Palotie (Aarno); A. Pouta (Anneli); S.M. Ring (Susan); U. Sovio (Ulla); M. Standl (Marie); A.G. Uitterlinden (André); E.H. Wichmann (Erich); N.H. Vissing (Nadja); C. DeCarli (Charles); C.M. van Duijn (Cornelia); M.I. McCarthy (M.); G.H. Koppelman (Gerard); X. Estivill (Xavier); A.T. Hattersley (Andrew); M. Melbye (Mads); H. Bisgaard (Hans); C.E. Pennell (Craig); E. Widen (Elisabeth); H. Hakonarson (Hakon); G. Davey-Smith (George); J. Heinrich (Joachim); M.-R. Jarvelin (Marjo-Riitta); V.W.V. Jaddoe (Vincent)

    2012-01-01

    textabstractTo identify genetic variants associated with head circumference in infancy, we performed a meta-analysis of seven genome-wide association studies (GWAS) (N = 10,768 individuals of European ancestry enrolled in pregnancy and/or birth cohorts) and followed up three lead signals in six

  6. Electrical transport properties of thermally evaporated phthalocyanine (H 2Pc) thin films

    Science.gov (United States)

    El-Nahass, M. M.; Farid, A. M.; Attia, A. A.; Ali, H. A. M.

    2006-08-01

    Thin films of H 2Pc of various thicknesses have been deposited onto glass substrates using thermal evaporation technique at room temperature. The dark electrical resistivity measurements were carried out at different temperatures in the range 298-473 K. An estimation of mean free path ( lo) of charge carriers in H 2Pc thin films was attempted. Measurements of thermoelectric power confirm that H 2Pc thin films behave as a p-type semiconductor. The current density-voltage characteristics of Au/H 2Pc/Au at room temperature showed ohmic conduction mechanism at low voltages. At higher voltages the space-charge-limited conduction (SCLC) accompanied by an exponential trap distribution was dominant. The temperature dependence of current density allows the determination of some essential parameters such as the hole mobility ( μh), the total trap concentration ( Nt), the characteristic temperature ( Tt) and the trap density P( E).

  7. Association of lipid profile and waist circumference as cardiovascular risk factors for overweight and obesity among school children in Qatar

    Directory of Open Access Journals (Sweden)

    Rizk NM

    2012-12-01

    Full Text Available Nasser M Rizk, Mervat YousefHealth Sciences Department, College of Arts and Sciences, Qatar University, Doha, QatarBackground: Childhood obesity is a national as well as worldwide problem. The aim of this study was to evaluate the association of overweight and obesity among Qatari children with lipid profile and waist circumference as adverse cardiovascular risk factors in children aged 6–11 years. International Obesity Task Force reference values were used to screen for overweight and obesity.Methods: A cross-sectional study in a randomly selected sample was conducted in 315 Qatari primary school students aged 6–11 years. Anthropometric measurements, including body weight, height, waist circumference, and body mass index were calculated for 151 girls and 164 boys. Weight categories were based on International Obesity Task Force reference values. Fasting blood glucose, total cholesterol, high-density lipoprotein cholesterol (HDL-C, low-density lipoprotein cholesterol (LDL-C, and triglycerides were measured, and atherogenic index was calculated.Results: In total, 31.71% of boys and 32.78% of girls were overweight or obese. Overweight and obese children screened against International Obesity Task Force reference values had a significantly increased risk of high waist circumference (P < 0.0001, hypertriglyceridemia (P = 0.002, low HDL-C (P = 0.017, and atherogenic index (P = 0.021 compared with children who were not overweight or obese. The partial correlation coefficient for the cardiovascular risk marker of waist circumference indicated a positive significant association with total cholesterol (r = 0.465, P = 0.003, triglycerides (r = 0.563, P < 0.001, and LDL-C (r = 0.267, P = 0.003, and a significant negative association with HDL-C (r = −0.361, P = 0.004. Overweight and obesity significantly increase the odds ratios (ORs and 95% confidence interval (CIs of cardiovascular risk factors as follows: hypertriglyceridemia (OR 6.34, CI 2.49–13

  8. Organic light-emitting diodes with F16CuPC as an efficient hole-injection layer

    International Nuclear Information System (INIS)

    Lee, H. K.; Shin, Y. C.; Kwon, D. S.; Lee, C. H.

    2006-01-01

    We report a new hole-injection material, copper hexadecafluorophthalocyanine (F 16 CuPC) for organic light-emitting diodes (OLEDs) consisting of N,N'-di(1-naphthyl)-N,N'-diphenylbenzidine (α-NPD) as a hole-transport layer and 8-tris-hydroxyquinoline aluminum (Alq 3 ) as a light-emitting and electron-transport layer. The insertion of the F 16 CuPC between indium-tin oxide (ITO) and α-NPD reduces the operating voltage significantly and thereby increases the luminous efficiency. By measuring the device characteristics for various F 16 CuPC thicknesses, we find that an optimum F 16 CuPC thickness is about 15 nm. At a luminance of 1000 cd/m 2 , the device with 15-nm-thick F 16 CuPC shows a luminous efficiency of 1.5 lm/W and a device operating voltage of 7.2 V while the device without the F 16 CuPC layer shows 1.1 lm/W and 10.4 V. The significant decrease in a driving voltage and increase in the luminous efficiency can be attributed to the high hole-injection efficiency when F 16 CuPC is inserted between ITO and α-NPD.

  9. Scale Marking Method on the Circumference of Circle Elements for Astronomical Instruments in the Early Joseon Dynasty

    Science.gov (United States)

    Mihn, Byeong-Hee; Lee, Ki-Won; Ahn, Young Sook; Lee, Yong Sam

    2015-03-01

    During the reign of King Sejong (世宗, 1418-1450) in the Joseon Dynasty, there were lots of astronomical instruments, including miniaturized ones. Those instruments utilized the technical know-how acquired through building contemporary astronomical instruments previously developed in the Song(宋), Jin(金), and Yuan(元) dynasties of China. In those days, many astronomical instruments had circles, rings, and spheres carved with a scale of 365.25, 100, and 24 parts, respectively, on their circumference. These were called the celestial-circumference degree, hundred-interval (Baekgak), and 24 direction, respectively. These scales are marked by the angular distance, not by the angle. Therefore, these circles, rings, and spheres had to be optimized in size to accomodate proper scales. Assuming that the scale system is composed of integer multiples of unit length, we studied the sizes of circles by referring to old articles and investigating existing artifacts. We discovered that the star chart of Cheonsang yeolcha bunyajido was drawn with a royal standard ruler (周尺) based on the unit length of 207 mm. Interestingly, its circumference was marked by the unit scale of 3 puns per 1 du (or degree) like Honsang (a celestial globe). We also found that Hyeonju ilgu (a equatorial sundial) has a Baekgak disk on a scale of 1 pun per 1 gak (that is an interval of time similar to a quarter). This study contributes to the analysis of specifications of numerous circular elements from old Korean astronomical instruments.

  10. The association of dementia with upper arm and waist circumference in seven low- and middle-income countries: the 10/66 cross-sectional surveys.

    Science.gov (United States)

    Taylor, Clare L; Albanese, Emiliano; Stewart, Robert

    2012-08-01

    Weight loss in dementia contributes to morbidity and mortality but the distribution of anthropometric change and its consistency between populations are less clear. Our aim was to investigate and compare the associations of dementia with waist and upper arm circumference in elders from seven low- and middle-income nations. Cross-sectional surveys were conducted of 15,022 residents aged 65 years and older in Cuba, Mexico, Venezuela, Peru, Dominican Republic, China, and India. Dementia was assessed using a cross-culturally validated algorithm, and anthropometric measurements were taken. Associations with dementia and dementia severity (clinical dementia rating scale) were investigated in linear regression models, with fixed-effects meta-analyses used to investigate between-country heterogeneity. Dementia and increased dementia severity were both associated with smaller arm and waist circumferences with little evidence of confounding by sociodemographic and health status. Associations between dementia/clinical dementia rating and arm circumference were homogeneous between countries (Higgins I(2) 0% and 7%, respectively), whereas those with waist circumference were more heterogeneous (Higgins I(2) 67% and 62%, respectively). Although cross-sectional, our findings are consistent with prospective observations of weight loss in dementia and suggest loss of both muscle and fat-the former being consistent across different settings and the latter being more context dependent.

  11. Epigenetic regulation of HIV-1 latency: focus on polycomb group (PcG) proteins.

    Science.gov (United States)

    Khan, Sheraz; Iqbal, Mazhar; Tariq, Muhammad; Baig, Shahid M; Abbas, Wasim

    2018-01-01

    HIV-1 latency allows the virus to persist until reactivation, in a transcriptionally silent form in its cellular reservoirs despite the presence of effective cART. Such viral persistence represents a major barrier to HIV eradication since treatment interruption leads to rebound plasma viremia. Polycomb group (PcG) proteins have recently got a considerable attention in regulating HIV-1 post-integration latency as they are involved in the repression of proviral gene expression through the methylation of histones. This epigenetic regulation plays an important role in the establishment and maintenance of HIV-1 latency. In fact, PcG proteins act in complexes and modulate the epigenetic signatures of integrated HIV-1 promoter. Key role played by PcG proteins in the molecular control of HIV-1 latency has led to hypothesize that PcG proteins may represent a valuable target for future HIV-1 therapy in purging HIV-1 reservoirs. In this regard, various small molecules have been synthesized or explored to specifically block the epigenetic activity of PcG. In this review, we will highlight the possible therapeutic approaches to achieve either a functional or sterilizing cure of HIV-1 infection with special focus on histone methylation by PcG proteins together with current and novel pharmacological approaches to reactivate HIV-1 from latency that could ultimately lead towards a better clearance of viral latent reservoirs.

  12. Yogurt consumption is associated with longitudinal changes of body weight and waist circumference: the framingham study

    Science.gov (United States)

    Yogurt, as a low-fat, nutrient-dense dairy product, may be beneficial in preventing weight gain. We aimed to examine the longitudinal association between yogurt consumption and annualized change in weight and waist circumference (WC) among adults. We included 3,285 adults (11,169 observations) parti...

  13. Seismic Adequacy Review of PC012 SCEs that are Potential Seismic Hazards with PC3 SCEs - CVD Facility

    International Nuclear Information System (INIS)

    OCOMA, E.C.

    1999-01-01

    This document provides seismic adequacy review of PCO12 Systems, Components L Equipment anchorage that are potential seismic interaction hazards with PC3 SCEs during a Design Basis Earthquake. The PCO12 items are identified in the Safety Equipment List as 3/1 SCEs

  14. The aPC treatment improves microcirculation in severe sepsis/septic shock syndrome

    NARCIS (Netherlands)

    Donati, Abele; Damiani, Elisa; Botticelli, Laura; Adrario, Erica; Lombrano, Maria Rita; Domizi, Roberta; Marini, Benedetto; van Teeffelen, Jurgen W. G. E.; Carletti, Paola; Girardis, Massimo; Pelaia, Paolo; Ince, Can

    2013-01-01

    The role of recombinant activated protein C (aPC) during sepsis is still controversial. It showed anti-inflammatory effect and improved the microvascular perfusion in experimental models of septic shock. The present study was aimed at testing the hypothesis that recombinant aPC therapy improves the

  15. USL/DBMS NASA/PC R and D project C programming standards

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Moreau, Dennis R.

    1984-01-01

    A set of programming standards intended to promote reliability, readability, and portability of C programs written for PC research and development projects is established. These standards must be adhered to except where reasons for deviation are clearly identified and approved by the PC team. Any approved deviation from these standards must also be clearly documented in the pertinent source code.

  16. Integrating a Single Tablet PC in Chemistry, Engineering, and Physics Courses

    Science.gov (United States)

    Rogers, James W.; Cox, James R.

    2008-01-01

    A tablet PC is a versatile computer that combines the computing power of a notebook with the pen functionality of a PDA (Cox and Rogers 2005b). The authors adopted tablet PC technology in order to improve the process and product of the lecture format in their chemistry, engineering, and physics courses. In this high-tech model, a single tablet PC…

  17. [Massive increase of foetal abdominal circumference due to hereditary polycystic kidney disease].

    Science.gov (United States)

    Dukic, L; Schaffelder, R; Schaible, T; Sütterlin, M; Siemer, J

    2010-06-01

    Autosomal recessive polycystic kidney disease (ARPKD) is a rare condition with a poor prognosis. We report on a 30-year-old primagravid woman in the 34th) week of gestation who was admitted to our hospital. ARPKD of the foetus had been sonographically suspected since the 26th week of gestation. Ultrasound examination showed big polycystic kidneys on both sides. The non-consanguineous parents wanted a maximum therapy for the infant. Foetal digitalisation because of heart insufficiency and prophylactic lung maturation was started. In the further course, Doppler sonographic values worsened and a Caesarean section was performed in the 34th week of gestation at the demand of the parents and due to the expected problems in case of a vaginal delivery. The weight of the newborn was 3,780 g and the abdominal circumference was 50 cm. The newborn was intubated immediately after birth and artificial ventilation was performed. Extracorporeal membrane oxygenation was not possible due to the bad cardial condition. The boy died 16 h after delivery. The parents refused genetic examination and autopsy of the newborn. ARPKD is a severe disease that may have obstetric relevance, due to the massively increased abdominal circumference. Therefore, termination of pregnancy or preterm induction of labor should be considered in order to avoid Caesarean section. Additionally, early prenatal diagnosis with genetic analysis of PRKD1 in cases of suspected ARPKD can be helpful. Georg Thieme Verlag KG Stuttgart, New York.

  18. PC based vibration monitoring system

    International Nuclear Information System (INIS)

    Jain, Sanjay K.; Roy, D.A.; Pithawa, C.K.; Patil, R.K.

    2004-01-01

    Health of large rotating machinery gets reflected in the vibration signature of the rotor and supporting structures and proper recording of these signals and their analysis can give a clear picture of the health of the machine. Using these data and their trending, it is possible to predict an impending trouble in the machine so that preventive action can be taken in time and catastrophic failure can be avoided. Continuous monitoring and analysis can give quick warning and enable operator to take preventive measures. Reactor Control Division, BARC is developing a PC based Vibration monitoring system for turbo generator machinery. The System can acquire 20 vibration signals at a rate of 5000 samples per second and also 15 process signals at a rate of 100 samples/ sec. The software for vibration monitoring system includes acquisition modules, analysis modules and Graphical User Interface module. The acquisition module involves initialization, setting of required parameters and acquiring the data from PC-based data acquisition cards. The acquired raw vibration data is then stored for analysis using various software packages. The display and analysis of acquired data is done in LabVIEW 7.0 where the data is displayed in time as well as frequency domain along with the RMS value of the signal. (author)

  19. PC driven integrated vacuum system

    International Nuclear Information System (INIS)

    Curuia, Marian; Culcer, Mihai; Brandea, Iulian; Anghel, Mihai

    2001-01-01

    The monitoring of industrial plants by virtual instrumentation represents the most modern trend in the domain of electronic equipment. The integrated vacuum system presented here has several facilities, including the automated data storing of measurement results on hard disk and providing warning messages for operators when the measured parameters are lower or higher upper than the fixed values. The system can also work stand-alone, receiving the commands from the keyboards placed on his front panel but, when it is included in a automation complex system, a remote control from PC is necessary . Both parts of the system, power supply unit for turbo-molecular pump and the vacuum gage, are controlled by an 80C31 microcontroller. Because this microcontroller has a built-in circuitry for a serial communication, we established a serial communication between the PC and the power supply unit for turbo-molecular pump and the vacuum gage, according to the RS-232 hardware standard. As software, after careful evaluation of several options, we chose to develop a hybrid software packing using two different software development tools: LabVIEW, and assembly language. We chose LabVIEW because it is dedicated to data acquisition and communications, containing libraries for data collection, analysis, display and storage. (authors)

  20. Bifenthrin inhibits neurite outgrowth in differentiating PC12 cells.

    Science.gov (United States)

    Tran, Van; Hoffman, Natalie; Mofunanaya, Adaobi; Pryor, Stephen C; Ojugbele, Olutosin; McLaughlin, Ashlea; Gibson, Lydia; Bonventre, Josephine A; Flynn, Katherine; Weeks, Benjamin S

    2006-02-01

    Bifenthrin is a third generation member of the synthetic pyrethroid family of insecticides. As a new pesticide within a relatively new class of pesticides, bifenthrin is considered relatively safe. Here, we used the PC12 neuronal cell line to examine the effect of bifenthrin on the formation of neurites and the potential developmental neurotoxicity of this pesticide. PC12 cells were exposed to varying concentrations of technical grade bifenthrin or Ortho Home Defense. Cell viability was determined using the AlmarBlue Toxicity Assay. Nontoxic concentrations of these chemicals were concomitantly with nerve growth factor and neurite outgrowth was assessed. Ortho Home Defense preparation reduced PC12 cell viability by approximately 50% and 70% at dilutions that correlate to bifenthrin concentrations of 10(-5) M and 10(-4) M, respectively. In contrast, technical grade bifenthrin, was not toxic to PC12 cells at 10(-3) M, which was the highest concentration tested that was soluble. At "nontoxic" concentrations of 10(-7) M and 10(-6) M, the Ortho Home Defense inhibited nerve growth factor-mediated neurite outgrowth by 30% and 55% respectively. Furthermore the nontoxic concentrations of technical grade bifenthrin of 10(-6) M and 10(-3) M inhibited neurite outgrowth by approximately 35% and 75% respectively. These data suggest that the toxicity of the Ortho Home Defense preparation was due to the "inert" additives in the preparation and not the bifenthrin itself. Further, these data suggest that, even in the absence of overt toxicity, bifenthrin may have deleterious effects to developing nervous system.

  1. PC Software for Artificial Intelligence Applications.

    Science.gov (United States)

    Epp, H; Kalin, M; Miller, D

    1988-05-06

    Our review has emphasized that AI tools are programming languages inspired by some problem-solving paradigm. We want to underscore their status as programming languages; even if an AI tool seems to fit a problem perfectly, its proficient use still requires the training and practice associated with any programming language. The programming manuals for PC-Plus, Smalltalk/ V, and Nexpert Object are all tutorial in nature, and the corresponding software packages come with sample applications. We find the manuals to be uniformly good introductions that try to anticipate the problems of a user who is new to the technology. All three vendors offer free technical support by telephone to licensed users. AI tools are sometimes oversold as a way to make programming easy or to avoid it altogether. The truth is that AI tools demand programming-but programming that allows you to concentrate on the essentials of the problem. If we had to implement a diagnostic system, we would look first to a product such as PC-Plus rather than BASIC or C, because PC-Plus is designed specifically for such a problem, whereas these conventional languages are not. If we had to implement a system that required graphical interfaces and could benefit from inheritance, we would look first to an object-oriented system such as Smalltalk/V that provides built-in mechanisms for both. If we had to implement an expert system that called for some mix of AI and conventional techniques, we would look first to a product such as Nexpert Object that integrates various problem-solving technologies. Finally, we might use FORTRAN if we were concerned primarily with programming a well-defined numerical algorithm. AI tools are a valuable complement to traditional languages.

  2. AceDoPC, a structured phospholipid to target the brain with docosahexaenoic acid

    Directory of Open Access Journals (Sweden)

    Lagarde Michel

    2016-01-01

    Full Text Available AceDoPC® is a structured phospholipid or acetyl-LysoPC-DHA made to prevent docosahexaenoic acyl migrating from the sn-2 to sn-1 position of the phospholipid, however keeping the main physical-chemical properties of LysoPC-DHA. As previously shown for LysoPC-DHA, AceDoPC® allows DHA crossing a re-constituted blood-brain barrier with higher efficiency than non-esterified DHA or PC-DHA. When injected to blood of rats, AceDoPC® is processed within the brain to deliver DHA to phosphatidyl-choline and -ethanolamine. When injected to rats following the induction of an ischemic stroke, AceDoPC® prevents the extension of brain lesions more efficiently than DHA. Overall, these properties make AceDoPC® a promising phospholipid carrier of DHA to the brain.

  3. Versatile PC-logger for radioisotope measurements

    International Nuclear Information System (INIS)

    Furman, L.; Petryka, L.; Przewlocki, K.; Stegowski, Z.; Wierzbicki, A.

    1998-01-01

    The logger, a personal computer and software is all to set up a radioisotope measuring system. It may find numerous applications in a wide range of disciplines: kinetics description of flow process in industry, slip velocity measurements in hydrotransport, flow rates evaluation in waste water treatment plants, nucleonic gauges in industry, ect. Readings from up to 4 scintillation detectors, the user has set to log, are stored in regular intervals. The user can set the logger to start and stop logging manually, with keyboard or from a program running on a connected PC. Stored data can be transferred to any computer with RS232 serial interface. The logger works equally well together with conventional PC's and 'lap-tops' for field work. Its internal program is stored in nonvolatile RAM. This makes it possible to upgrade or change the code by just down loading a new one. The logger is internal rechargeable batteries for measuring off-line; they remain as a back-up in case the external supply is disconnected or fails. (author)

  4. [Inhibition effects of black rice pericarp extracts on cell proliferation of PC-3 cells].

    Science.gov (United States)

    Jiang, Weiwei; Yu, Xudong; Ren, Guofeng

    2013-05-01

    To observe the inhibitive effects of black rice pericarp extracts on cell proliferation of human prostate cancer cell PC-3 and to explore its effecting mechanism. The black rice pericarp extract was used to treat the PC-3 cells. The inhibitory effect of black rice pericarp extract on cells proliferation of PC-3 was tested by MTT method. Cell apoptosis rates and cell cycle were measured by flow cytometric assay (FCM). Western blot was used to study the protein expression levels of p38, p-p38, JNK, p-JNK. A dose-dependent and time-dependent proliferation inhibition of black rice pericarp extract was demonstrated in PC-3. The most prominent experiment condition was inhibitory concentration with 300microg/ml and treated for 72 h. The experiment result of flow cytometry analysis demonstrates that the apoptosis rate of PC-3 cells increased along with the increasing of black rice pericarp extract concentration, and a G1-S cell cycle arrest was induced in a dose-dependent manner. After PC-3 cell was treated with black rice pericarp extract for 72 h, the expressions of p-p38, p-JNK protein increased. Black rice pericarp extract could inhibit proliferation, change the cell cycle distributions and induce apoptosis in human prostatic cancer cell PC-3. Its inhibitory effect may be through promoting activation of the JNK, p38 signaling pathway. These results suggest that black rice pericarp extract maybe has an inhibitory effect on prostatic cancer.

  5. The Relationship of Violence and Traumatic Stress to Changes in Weight and Waist Circumference: Longitudinal Analyses from the Study of Women’s Health Across the Nation (SWAN)

    Science.gov (United States)

    Garcia, Lorena; Qi, Lihong; Rasor, Marianne; Gold, Ellen B; Clark, Cari; Bromberger, Joyce

    2013-01-01

    Objective To investigate the associations of violence and traumatic stress with changes in weight and waist circumference, hypothesizing that violence in midlife would be associated with increases or decreases in weight and waist circumference. Methods The longitudinal cohort of the Study of Women’s Health Across the Nation (SWAN) comprised the study sample, which included an ethnically/racially and socially diverse group of 2870 women between the ages of 42 and 52 years at baseline. Women were followed annually for 10 years and assessments included weight and waist circumference measures and data on violence, health outcomes and confounders. Results At baseline, 8.6% Caucasian, 10.8% African American, 9.2% Chinese and 5.0% Japanese women reported violence and traumatic stress. Reporting violence and traumatic stress during follow-up was significantly associated with weight gain (OR=2.39, 95% CI= 1.28, 4.47), weight loss (OR=3.54, 95% CI=1.73, 7.22), and gain (OR=2.44, 95% CI =1.37, 4.37) or loss (OR=2.66, 95% CI=1.23, 5.77) in waist circumference, adjusting for age, race/ethnicity, education, marital status, and smoking. Conclusion Violence and traumatic stress against midlife women was associated with gains or losses in weight and waist circumference. PMID:24212978

  6. IBM PC based real time photon correlator [Paper No.:D2

    International Nuclear Information System (INIS)

    Kumaravadivelu, C.; Nageswaran, A.; Weling, S. A.

    1993-01-01

    The design aspects and development of IBM PC based real time photon correlator is presented. This system computes 64 auto-correlation functions in real time. Sample data is 4-bit wide. Correlation functions are computed in hard wired logic using discrete components. A combination of parallel and pipelined architecture is adopted to compute the correlation in realtime. A high speed controller generates the required control signals for the computing hardware and also provides handshake signals to IBM PC to access the computed results. IBM PC bus is extended and interfaced to correlation computing hardware. IBM PC collects the experimental parameters through user friendly menu and initiates the correlation hardware and continues to collect the correlation build ups and displays them on the screen. Extensive test and maintenance features are incorporated into the system. This system is developed for Material Science Division in Indira Gandhi Centre for Atomic Research (IGCAR) to study static and dynamic properties of macro molecules and colloidal particles in dispersion using light scattering technique. It can also be used to study the flow characteristics of sodium in nuclear reactors. It can be used in dynamic neutron scattering experiments. (author). 3 figs., 2 tabs

  7. Evaluation of thermodynamic properties of fluid mixtures by PC-SAFT model

    International Nuclear Information System (INIS)

    Almasi, Mohammad

    2014-01-01

    Experimental and calculated partial molar volumes (V ¯ m,1 ) of MIK with (♦) 2-PrOH, (♢) 2-BuOH, (●) 2-PenOH at T = 298.15 K. (—) PC-SAFT model. - Highlights: • Densities and viscosities of the mixtures (MIK + 2-alkanols) were measured. • PC-SAFT model was applied to correlate the volumetric properties of binary mixtures. • Agreement between experimental data and calculated values by PC-SAFT model is good. - Abstract: Densities and viscosities of binary mixtures of methyl isobutyl ketone (MIK) with polar solvents namely, 2-propanol, 2-butanol and 2-pentanol, were measured at 7 temperatures (293.15–323.15 K) over the entire range of composition. Using the experimental data, excess molar volumes V m E , isobaric thermal expansivity α p , partial molar volumes V ¯ m,i and viscosity deviations Δη, have been calculated due to their importance in the study of specific molecular interactions. The observed negative and positive values of deviation/excess parameters were explained on the basis of the intermolecular interactions occur in these mixtures. The Perturbed Chain Statistical Association Fluid Theory (PC-SAFT) has been used to correlate the volumetric behavior of the mixtures

  8. Effect of season on scrotal circumference, semen characteristics, seminal plasma composition and spermatozoa motility during liquid storage in INRA180 rams.

    Science.gov (United States)

    Benmoula, Anass; Badi, Abdelmoughit; El Fadili, Moussa; El Khalil, Kaoutar; Allai, Larbi; El Hilali, Abderaouf; El Amiri, Bouchra

    2017-05-01

    The present study was undertaken to assess the effect of seasons on scrotal circumference, semen characteristics, seminal plasma composition, and sperm motility during liquid storage of INRA180 rams. The semen was collected from five mature INRA180 rams (2-3 years of age) during one year (from April 2014 to March 2015). Scrotal circumferences, semen characteristics, some biochemical parameters of seminal plasma were evaluated. Immediately after collection and evaluation, the semen was pooled and extended in skim milk (SM) at 15°C to reach 0.8×109 spermatozoa/ml. Thereafter, samples were evaluated at different storage times (0, 8, and 24h). The results showed that scrotal circumference, semen quality and the concentration of total protein in seminal plasma were relatively constant during the year (P>0.05). However, total lipid and cholesterol concentrations increased significantly (P0.05). To conclude, the INRA180 rams have the ability to produce semen with high quality all over the year. The only parameters showing seasonal variations are cholesterol, total lipid, and progressive motility. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Use of laser-induced breakdown spectroscopy for the determination of polycarbonate (PC) and acrylonitrile-butadiene-styrene (ABS) concentrations in PC/ABS plastics from e-waste.

    Science.gov (United States)

    Costa, Vinicius Câmara; Aquino, Francisco Wendel Batista; Paranhos, Caio Marcio; Pereira-Filho, Edenir Rodrigues

    2017-12-01

    Due to the continual increase in waste generated from electronic devices, the management of plastics, which represents between 10 and 30% by weight of waste electrical and electronic equipment (WEEE or e-waste), becomes indispensable in terms of environmental and economic impacts. Considering the importance of acrylonitrile-butadiene-styrene (ABS), polycarbonate (PC), and their blends in the electronics and other industries, this study presents a new application of laser-induced breakdown spectroscopy (LIBS) for the fast and direct determination of PC and ABS concentrations in blends of these plastics obtained from samples of e-waste. From the LIBS spectra acquired for the PC/ABS blend, multivariate calibration models were built using partial least squares (PLS) regression. In general, it was possible to infer that the relative errors between the theoretical or reference and predicted values for the spiked samples were lower than 10%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Physical activity, diet and gene-environment interactions in relation to body mass index and waist circumference

    DEFF Research Database (Denmark)

    Karnehed, Nina; Tynelius, Per; Heitmann, Berit L

    2006-01-01

    OBJECTIVE: The aim of the present study was to examine the relationships between genetic susceptibility to obesity, physical activity (PA), dietary fibre, sugar and fat intakes and 4-year changes in body mass index (BMI) and attained waist circumference (WC) in a cohort of 287 monozygotic and 189...

  11. Quasi-Chemical PC-SAFT: An Extended Perturbed Chain-Statistical Associating Fluid Theory for Lattice-Fluid Mixtures.

    Science.gov (United States)

    Parvaneh, Khalil; Shariati, Alireza

    2017-09-07

    In this study, a new modification of the perturbed chain-statistical associating fluid theory (PC-SAFT) has been proposed by incorporating the lattice fluid theory of Guggenheim as an additional term to the original PC-SAFT terms. As the proposed model has one more term than the PC-SAFT, a new mixing rule has been developed especially for the new additional term, while for the conventional terms of the PC-SAFT, the one-fluid mixing rule is used. In order to evaluate the proposed model, the vapor-liquid equilibria were estimated for binary CO 2 mixtures with 16 different ionic liquids (ILs) of the 1-alkyl-3-methylimidazolium family with various anions consisting of bis(trifluoromethylsulfonyl) imide, hexafluorophosphate, tetrafluoroborate, and trifluoromethanesulfonate. For a comprehensive comparison, three different modes (different adjustable parameters) of the proposed model were compared with the conventional PC-SAFT. Results indicate that the proposed modification of the PC-SAFT EoS is generally more reliable with respect to the conventional PC-SAFT in all the three proposed modes of vapor-liquid equilibria, giving good agreement with literature data.

  12. Effect of spermidine in PC12 cells on the cell apoptosis induced by enriched uranium

    International Nuclear Information System (INIS)

    Gu Guixiong; Zhu Shoupeng; Wang Liuyi; Yang Shuqin; Zhu Lingli

    2003-01-01

    This is a study on injurious effects of cellular spermidine to PC12 cells irradiated by enriched uranium. PC12 cells were cultured in DMEM/F12 medium with enriched uranium, and the exposure doses were calculated. The contents of free spermidine PC12 cells were examined with Dansyl-chloride reaction and thin-layer chromatography. Viability of the cells treated with enriched uranium reduced rapidly and DNA strand break increased significantly with increasing time of the irradiation. Autoradiographic tracks showed that the radionuclide located in the nucleus predominantly. The content of free spermidine in PC12 cells could markedly decrease as the irradiation time increased. The results suggested that PC12 cells exposured to enriched uranium were apoptotic and the free spermidine in cells might play some role in this process

  13. A Comparison of the Apple Macintosh and IBM PC in Laboratory Applications.

    Science.gov (United States)

    Williams, Ron

    1986-01-01

    Compares Apple Macintosh and IBM PC microcomputers in terms of their usefulness in the laboratory. No attempt is made to equalize the two computer systems since they represent opposite ends of the computer spectrum. Indicates that the IBM PC is the most useful general-purpose personal computer for laboratory applications. (JN)

  14. The white dwarfs within 25 pc of the Sun: Kinematics and spectroscopic subtypes

    Energy Technology Data Exchange (ETDEWEB)

    Sion, Edward M.; McCook, George P.; Wasatonic, Richard; Myszka, Janine [Department of Astronomy and Astrophysics, Villanova University, Villanova, PA 19085 (United States); Holberg, J. B. [Lunar and Planetary Laboratory, University of Arizona, Tucson, AZ 75201 (United States); Oswalt, Terry D., E-mail: edward.sion@villanova.edu, E-mail: george.mccook@villanova.edu, E-mail: richard.wasatonic@villanova.edu, E-mail: janine.myszka@villanova.edu, E-mail: holberg@vega.lpl.arizona.edu, E-mail: toswalt@fit.edu [Department of Physics and Space Sciences, Florida Institute of Technology, Melbourne, FL 19085 (United States)

    2014-06-01

    We present the fractional distribution of spectroscopic subtypes, range and distribution of surface temperatures, and kinematical properties of the white dwarfs (WDs) within 25 pc of the Sun. There is no convincing evidence of halo WDs in the total 25 pc sample of 224 WDs. There is also little to suggest the presence of genuine thick disk subcomponent members within 25 pc. It appears that the entire 25 pc sample likely belongs to the thin disk. We also find no significant kinematic differences with respect to spectroscopic subtypes. The total DA to non-DA ratio of the 25 pc sample is 1.8, a manifestation of deepening envelope convection, which transforms DA stars with sufficiently thin H surface layers into non-DAs. We compare this ratio with the results of other studies. We find that at least 11% of the WDs within 25 pc of the Sun (the DAZ and DZ stars) have photospheric metals that likely originate from accretion of circumstellar material (debris disks) around them. If this interpretation is correct, then it suggests the possibility that a similar percentage have planets, asteroid-like bodies, or debris disks orbiting them. Our volume-limited sample reveals a pileup of DC WDs at the well-known cutoff in DQ WDs at T {sub eff} ∼ 6000 K. Mindful of small number statistics, we speculate on its possible evolutionary significance. We find that the incidence of magnetic WDs in the 25 pc sample is at least 8% in our volume-limited sample, dominated by cool WDs. We derive approximate formation rates of DB and DQ degenerates and present a preliminary test of the evolutionary scenario that all cooling DB stars become DQ WDs via helium convective dredge-up with the diffusion tail of carbon extending upward from their cores.

  15. Using the AUDIT-PC to predict alcohol withdrawal in hospitalized patients.

    Science.gov (United States)

    Pecoraro, Anna; Ewen, Edward; Horton, Terry; Mooney, Ruth; Kolm, Paul; McGraw, Patty; Woody, George

    2014-01-01

    Alcohol withdrawal syndrome (AWS) occurs when alcohol-dependent individuals abruptly reduce or stop drinking. Hospitalized alcohol-dependent patients are at risk. Hospitals need a validated screening tool to assess withdrawal risk, but no validated tools are currently available. To examine the admission Alcohol Use Disorders Identification Test-(Piccinelli) Consumption (AUDIT-PC) ability to predict the subsequent development of AWS among hospitalized medical-surgical patients admitted to a non-intensive care setting. Retrospective case–control study of patients discharged from the hospital with a diagnosis of AWS. All patients with AWS were classified as presenting with AWS or developing AWS later during admission. Patients admitted to an intensive care setting and those missing AUDIT-PC scores were excluded from analysis. A hierarchical (by hospital unit) logistic regression was performed and receiver-operating characteristics were examined on those developing AWS after admission and randomly selected controls. Because those diagnosing AWS were not blinded to the AUDIT-PC scores, a sensitivity analysis was performed. The study cohort included all patients age ≥18 years admitted to any medical or surgical units in a single health care system from 6 October 2009 to 7 October 2010. After exclusions, 414 patients were identified with AWS. The 223 (53.9 %) who developed AWS after admission were compared to 466 randomly selected controls without AWS. An AUDIT-PC score ≥4 at admission provides 91.0 % sensitivity and 89.7 % specificity (AUC=0.95; 95 % CI, 0.94–0.97) for AWS, and maximizes the correct classification while resulting in 17 false positives for every true positive identified. Performance remained excellent on sensitivity analysis (AUC=0.92; 95 % CI, 0.90–0.93). Increasing AUDIT-PC scores were associated with an increased risk of AWS (OR=1.68, 95 % CI 1.55–1.82, pAUDIT-PC score is an excellent discriminator of AWS and could be an important component

  16. PC-Link historical data base system MODCOMP/IBM at link for neutral particle beam operation

    International Nuclear Information System (INIS)

    Thurgood, P.

    1989-01-01

    PC-Link is a combination of hardware and software that connects an IBM PC/AT to a MODCOMP minicomputer. It is designed as an aid to the Neutral Beam operations coordinator during injection into the DIII-D tokamak project. An IBM PC/AT is linked to 4 MODCOMP realtime acquisition systems, each of which controls 2 neutral particle beam sources. At various points in the shot sequence, data is sent to the IBM PC/AT. This data can then be integrated with the data from the other sources into tables or graphics displays for use by the Beam Coordinator. In this way, the coordinator gets realtime feedback on the relative settings and performance of the sources and can observe trends within a particular source at one location. The PC-Link is used for observing relative timing information and for post shot historical archiving. The concept of the PC-Link was originally proposed several years ago. In April 1988, in-house implementation of the link software was begun. The PC-Link receives approximately 2 Kbytes of data per source per shot. This data is converted from MODCOMP format to IBM PC format and archived to disk. The last 280 shots per source are stored to disk to observe trends. The data can be displayed in a number of formats depending upon the situation. For example, prior to a shot, the beam MODCOMPs are sent timing information from the DIII-D tokamak control system. This data is echoed on the PC in a graphical representation displaying all 8 sources. At the end of the shot, the actual running times are displayed along with the requested settings. Any subset of the Historical data may be displayed either graphically or in tables for realtime comparisons between sources. 4 figs

  17. Toward the optimization of PC-based training

    Science.gov (United States)

    Cho, Kohei; Murai, Shunji

    Since 1992, the National Space Development Agency of Japan (NASDA) and the Economic and Social Commission for Asia and the Pacific (ESCAP) have been co-organising the Regional Remote Sensing Seminar on Tropical Ecosystem Management (Program Chairman: Prof. Shunji Murai) every year in some country in Asia. In these seminars, the members of the ISPRS Working Group VI/2 'Computer Assisted Teaching' have been performing a PC-based hands-on-training on remote sensing and GIS for beginners. The main objective of the training was to transfer not only knowledge but also the technology of remote sensing and GIS to the beginners. The software and CD-ROM data set provided at the training were well designed not only for training but also for practical data analysis. This paper presents an outline of the training and discusses the optimisation of PC-based training for remote sensing and GIS.

  18. Height, waist circumference, body mass index, and body somatotype across the life course and risk of glioma.

    Science.gov (United States)

    Cote, David J; Downer, Mary K; Smith, Timothy R; Smith-Warner, Stephanie A; Egan, Kathleen M; Stampfer, Meir J

    2018-06-26

    Recent studies have suggested height as a risk factor for glioma, but less is known regarding body mass index (BMI) or other anthropomorphic measures. We evaluated the association between body habitus and risk of glioma. We evaluated the association of measures of height, BMI, waist circumference, and somatotypes with risk of glioma in two prospective cohorts, the Nurses' Health Study and the Health Professionals Follow-Up Study. We documented 508 incident cases of glioma (321 glioblastoma [GBM]). In both cohorts, we found no significant association between adult BMI or waist circumference and risk of glioma, with pooled HR for BMI of 1.08 (95% CI 0.85-1.38 comparing ≥ 30 to < 25 kg/m 2 ) and for waist circumference of 1.05 (95% CI 0.80-1.37 highest vs. lowest quintile). Higher young adult BMI (at age 18 in NHS and 21 in HPFS) was associated with modestly increased risk of glioma in the pooled cohorts (pooled HR 1.35, 95% CI 1.06-1.72 comparing ≥ 25 kg/m 2 vs. less; HR 1.34 for women and 1.37 for men). Analysis of body somatotypes suggested reduced risk of glioma among women with heavier body types at all ages this measure was assessed (HRs ranging from 0.52 to 0.65 comparing highest tertile to lowest tertile), but no significant association among men. Height was associated with increased risk of glioma among women (HR 1.09, 95% CI 1.04-1.14 per inch), but not significantly among men. Within the 8 years prior to diagnosis, cases had no material weight loss compared to non-cases. All results were similar when limited to GBM. Adult BMI and waist circumference were not associated with glioma. Higher BMI at age 21 for men and at age 18 for women was modestly associated with risk in the pooled cohort. Based on body somatotypes, however, women with heavier body types during childhood and young adulthood may be at lower risk of glioma, although this association was not observed later in life with measurements of BMI. Greater height was associated with

  19. EZVIDEO, DISSPLA Graphics Software Simulation on IBM PC

    International Nuclear Information System (INIS)

    1991-01-01

    1 - Description of program or function: EZVIDEO simulates a subset of the DISSPLA plotting package to make plots on the IBM PC screen. Screen dumps can also be made to an attached LaserJet or Epson printer to make hard copy without using terminal emulators. The forerunner of EZVIDEO was called EZPLOT. 2 - Method of solution: The subroutines in the EZVIDEO system are based on the Hewlett Packard HP 9000 simulation of DISSPLA. These routines manipulate the pen movements on the screen and are also capable of capturing these same movements so that a hardcopy can be made to dot matrix or laser printer. 3 - Restrictions on the complexity of the problem: For plotting on the IBM PC, the plotting emulator PCPLOT is needed

  20. Organic Photovoltaic Cells Based on PbPc Nanocolumns Prepared by Glancing Angle Deposition

    Directory of Open Access Journals (Sweden)

    Yang Liu

    2013-01-01

    Full Text Available Organic small material lead phthalocyanine (PbPc nanocolumns were prepared via glancing angle deposition (GLAD on indium tin oxide (ITO coated glass substrates. Organic electron acceptor materials fullerene (C60 was evaporated onto the nanocolumn PbPc thin films to prepare heterojunction structure ITO/PbPc/C60/Bphen/Al organic photovoltaic cells (OPVs. It is worthwhile to mention that C60 molecules firstly fill the voids between PbPc nanocolumns and then form impact C60 layer. The interpenetrating electron donor/acceptor structure effectively enhances interface between electron donor and electron acceptor, which is beneficial to exciton dissociation. The short circuit current density (Jsc of organic photovoltaic devices (OPVs based on PbPc nanocolumn was increased from 1.19 mA/cm2 to 1.74 mA/cm2, which should be attributed to the increase of interface between donor and acceptor. The effect of illumination intensity on the performance of OPVs was investigated by controlling the distance between light source and sample, and the Jsc of two kind of OPVs was increased along with the increase of illumination intensity.

  1. Waist circumference as a measurement of obesity in the Netherlands Antilles; associations with hypertension and diabetes mellitus

    NARCIS (Netherlands)

    Grievink, L.; Alberts, J.F.; O'Neil, J.; Gerstenbluth, I.

    Objectives: To evaluate waist circumference ( WC) as a screening tool for obesity in a Caribbean population. To identify risk groups with a high prevalence of ( central) obesity in a Caribbean population, and to evaluate associations between ( central) obesity and self-reported hypertension and

  2. Macronutrients Association with Change in Waist and Hip Circumference Over 9 Years.

    Science.gov (United States)

    Lofley, Amy C; Root, Martin M

    2017-01-01

    The calorie distribution of macronutrients affects individuals' health. Quantity and source of macronutrients may play major roles in waist circumference (WC) and hip circumference (HC). This study's purpose is to investigate the association between the quantity and source of macronutrients and the change in WC and HC over 9 years. Participants (N = 11,343) were from the Atherosclerosis Risk in Community Study. Those diagnosed with cancer or a decrease in WC or HC of 15 cm or more over 9 years were excluded. Change scores were created for anthropometrics between clinic visits over 9 years. Macronutrient intakes were assessed by a food frequency questionnaire at visit 1 and presented as a percentage of energy intake. Linear regressions were performed with quartiles of dietary components on change scores for WC and HC with controlling cofactors. Gender subgroup analysis was performed. A larger increase in WC was associated with higher intakes of total carbohydrates, dietary fiber, and fructose (p for trend Macronutrient source and quantity play a significant role in individuals' adiposity and effects on WC and HC. Overall, an increase in WC and HC was seen over the 11 years. The source and quantity of the macronutrients play a significant role in WC and HC. Further research needs to be conducted to see the exact effect that macronutrients play on WC and HC.

  3. Code for plant identification (KKS) key in PC version. KKS-Schluessel-Programm in PC-Version

    Energy Technology Data Exchange (ETDEWEB)

    Pannenbaecker, K. (GABO Gesellschaft fuer Ablauforganisation und Informationsverarbeitung mbH, Erlangen (Germany) GABO Gesellschaft fuer Ablauforganisation und Informationsverarbeitung mbH, Muenchen (Germany))

    1991-11-01

    The plant identification system (KKS) as a common development of german plant operators, erection firms and also power plant oriented organisations have decisively influenced the technical-organizing activities of planning and erections as operations and maintenance of all kind of power plants. Fundamentals are three key parts, operation, armatures and function keys. Their management and application is executed by a plantidentification-key code in a PC version, which is briefly described in this report. (orig.).

  4. Proteomic analysis of PC12 cell differentiation induced by ionizing radiation

    International Nuclear Information System (INIS)

    Zhang Junquan; Gao Ronglian; Chen Xiaohua; Wang Zhidong; Dong Bo; Rao Yalan; Hou Lili; Zhang Hao; Mao Bingzhi

    2005-01-01

    Objective: To explore the molecular mechanism of PC12 cell differentiation induced by ionizing radiation and screen the molecular target of nervous system injured by irradiation. Methods: PC12 cells were irradiated with 16 Gy 60 Co γ ray. Total proteins of normal and irradiated cells were prepared 48 hours after irradiation and separated with two dimensional gel electrophoresis. Some differential expressed proteins were characterized with mass spectrometry. Results: 876 differential expressed proteins were observed. Up-regulated expression of ubiquitin carboxyl-terminal hydratase L1 was found. Down-regulated expression of new protein similar to HP1α was found. Conclusion: The characterization of some differential expressed proteins through proteomic analysis would benefit the research of molecular mechanism of PC12 cell differentiation induced by ionizing radiation. (authors)

  5. Ballooning-mirror instability and internally driven Pc 4--5 wave events

    International Nuclear Information System (INIS)

    Cheng, C.Z.; Qian, Q.; Takahashi, K.; Lui, A.T.Y.

    1994-03-01

    A kinetic-MHD field-aligned eigenmode stability analysis of low frequency ballooning-mirror instabilities has been performed for anisotropic pressure plasma sin the magnetosphere. The ballooning mode is mainly a transverse wave driven unstable by pressure gradient in the bad curvature region. The mirror mode with a dominant compressional magnetic field perturbation is excited when the product of plasma beta and pressure anisotropy (P perpendicular /P parallel > 1) is large. From the AMPTE/CCE particle and magnetic field data observed during Pc 4--5 wave events the authors compute the ballooning-mirror instability parameters and perform a correlation study with the theoretical instability threshold. They find that compressional Pc 5 waves approximately satisfy the ballooning-mirror instability condition, and transverse Pc 4--5 waves are probably related to resonant ballooning instabilities with small pressure anisotropy

  6. Low-Temperature Electrical Characteristics of Si-Based Device with New Tetrakis NiPc-SNS Active Layer

    Science.gov (United States)

    Yavuz, Arzu Büyükyağci; Carbas, Buket Bezgın; Sönmezoğlu, Savaş; Soylu, Murat

    2016-01-01

    A new tetrakis 4-(2,5-di-2-thiophen-2-yl-pyrrol-1-yl)-substituted nickel phthalocyanine (NiPc-SNS) has been synthesized. This synthesized NiPc-SNS thin film was deposited on p-type Si substrate using the spin coating method (SCM) to fabricate a NiPc-SNS/ p-Si heterojunction diode. The temperature-dependent electrical characteristics of the NiPc-SNS/ p-Si heterojunction with good rectifying behavior were investigated by current-voltage ( I- V) measurements between 50 K and 300 K. The results indicate that the ideality factor decreases while the barrier height increases with increasing temperature. The barrier inhomogeneity across the NiPc-SNS/ p-Si heterojunction reveals a Gaussian distribution at low temperatures. These results provide further evidence of the more complicated mechanisms occurring in this heterojunction. Based on these findings, NiPc-SNS/ p-Si junction diodes are feasible for use in low-temperature applications.

  7. Higher household income and the availability of electronic devices and transport at home are associated with higher waist circumference in Colombian children: the ACFIES study.

    Science.gov (United States)

    Gómez-Arbeláez, Diego; Camacho, Paul A; Cohen, Daniel D; Rincón-Romero, Katherine; Alvarado-Jurado, Laura; Pinzón, Sandra; Duperly, John; López-Jaramillo, Patricio

    2014-02-07

    The current "epidemic" of childhood obesity is described as being driven by modern lifestyles with associated socioeconomic and environmental changes that modify dietary habits, discourage physical activity and encourage sedentary behaviors. To evaluate the association between household income and the availability of electronic devices and transport at home, and the values of waist circumference (WC), as an indicator of abdominal obesity, in children and adolescents from Bucaramanga, Colombia. Cross-sectional study of public elementary and high school population, of low-middle socioeconomic status. A total of 668 schoolchildren were recruited. After adjusting for potential confounders, significant positive associations between waist circumference and higher household income (p = 0.011), and waist circumference and the availability of electronic devices and transport at home (p = 0.026) were found. In low-middle socioeconomic status schoolchildren in a developing country, those from relatively more affluent families had greater waist circumference, an association that is opposite to that observed in developed countries. This finding could be related to higher income family's ability to purchase electronic devices and motorized transport which discourage physical activity and for their children to buy desirable and more costly western fast food.

  8. Off-Center Rotation of CuPc Molecular Rotor on a Bi(111) Surface and the Chiral Feature.

    Science.gov (United States)

    Sun, Kai; Tao, Min-Long; Tu, Yu-Bing; Wang, Jun-Zhong

    2017-05-04

    Molecular rotors with an off-center axis and the chiral feature of achiral CuPc molecules on a semi-metallic Bi(111) surface have been investigated by means of a scanning tunneling microscopy (STM) at liquid nitrogen (LN₂) temperature. The rotation axis of each CuPc molecular rotor is located at the end of a phthalocyanine group. As molecular coverage increases, the CuPc molecules are self-assembled into various nanoclusters and finally into two-dimensional (2D) domains, in which each CuPc molecule exhibits an apparent chiral feature. Such chiral features of the CuPc molecules can be attributed to the combined effect of asymmetric charge transfer between the CuPc and Bi(111) substrate, and the intermolecular van der Waals interactions.

  9. Scale Marking Method on the Circumference of Circle Elements for Astronomical Instruments in the Early Joseon Dynasty

    Directory of Open Access Journals (Sweden)

    Byeong-Hee Mihn

    2015-03-01

    Full Text Available During the reign of King Sejong (世宗, 1418-1450 in the Joseon Dynasty, there were lots of astronomical instruments, including miniaturized ones. Those instruments utilized the technical know-how acquired through building contemporary astronomical instruments previously developed in the Song(宋, Jin(金, and Yuan(元 dynasties of China. In those days, many astronomical instruments had circles, rings, and spheres carved with a scale of 365.25, 100, and 24 parts, respectively, on their circumference. These were called the celestial-circumference degree, hundred-interval (Baekgak, and 24 direction, respectively. These scales are marked by the angular distance, not by the angle. Therefore, these circles, rings, and spheres had to be optimized in size to accomodate proper scales. Assuming that the scale system is composed of integer multiples of unit length, we studied the sizes of circles by referring to old articles and investigating existing artifacts. We discovered that the star chart of Cheonsang yeolcha bunyajido was drawn with a royal standard ruler (周尺 based on the unit length of 207 mm. Interestingly, its circumference was marked by the unit scale of 3 puns per 1 du (or degree like Honsang (a celestial globe. We also found that Hyeonju ilgu (a equatorial sundial has a Baekgak disk on a scale of 1 pun per 1 gak (that is an interval of time similar to a quarter. This study contributes to the analysis of specifications of numerous circular elements from old Korean astronomical instruments.

  10. Application of miniature heat pipe for notebook PC cooling

    Energy Technology Data Exchange (ETDEWEB)

    Moon, S.H.; Hwang, G.; Choy, T.G. [Electronics and Telecommunications research Institute, Taejeon (Korea)

    2001-06-01

    Miniature heat pipe(MHP) with woven-wired wick was used to cool the CPU of a notebook PC. The pipe with circular cross-section was pressed and bent for packaging the MHP into a notebook PC with very limited compact packaging space. A cross-sectional area of the pipe is reduced about 30% as the MHP with 4 mm diameter is pressed to 2 mm thickness. In the present study a performance test has been performed in order to review varying of operating performance according to pressed thickness variation and heat dissipation capacity of MHP cooling module that is packaged on a notebook PC. New wick type was considered for overcoming low heat transfer limit when MHP is pressed to thin-plate. The limiting thickness of pressing is shown to be within the range of 2 mm {approx} 2.5 mm through the performance test with varying the pressing thickness. When the wall thickness of 0.4 mm is reduced to 0.25 mm for minimizing conductive thermal resistance through the wall of heat pipe, heat transfer limit and thermal resistance of MHP were improved about 10%. In the meantime, it is shown that the thermal resistance and heat transfer limit for the MHP with central wick type are higher than those of MHP with existing wick types. The results of performance test for MHP cooling modules with woven-wired wick to cool notebook PC shows the stability as cooling system since T{sub j}(Temperature of Processor Junction) satisfy a demand condition of 0 {approx} 100 deg.C under 11.5 W of CPU heat. (author). 6 refs., 7 figs.

  11. Opposite Roles of Furin and PC5A in N-Cadherin Processing

    Directory of Open Access Journals (Sweden)

    Deborah Maret

    2012-10-01

    Full Text Available We recently demonstrated that lack of Furin-processing of the N-cadherin precursor (proNCAD in highly invasive melanoma and brain tumor cells results in the cell-surface expression of a nonadhesive protein favoring cell migration and invasion in vitro. Quantitative polymerase chain reaction analysis of malignant human brain tumor cells revealed that of all proprotein convertases (PCs only the levels of Furin and PC5A are modulated, being inversely (Furin or directly (PC5A correlated with brain tumor invasive capacity. Intriguingly, the N-terminal sequence following the Furin-activated NCAD site (RQKR↓DW161, mouse nomenclature reveals a second putative PC-processing site (RIRSDR↓DK189 located in the first extracellular domain. Cleavage at this site would abolish the adhesive functions of NCAD because of the loss of the critical Trp161. This was confirmed upon analysis of the fate of the endogenous prosegment of proNCAD in human malignant glioma cells expressing high levels of Furin and low levels of PC5A (U343 or high levels of PC5A and negligible Furin levels (U251. Cellular analyses revealed that Furin is the best activating convertase releasing an ∼17-kDa prosegment, whereas PC5A is the major inactivating enzyme resulting in the secretion of an ∼20-kDa product. Like expression of proNCAD at the cell surface, cleavage of the NCAD molecule at RIRSDR↓DK189 renders the U251 cancer cells less adhesive to one another and more migratory. Our work modifies the present view on posttranslational processing and surface expression of classic cadherins and clarifies how NCAD possesses a range of adhesive potentials and plays a critical role in tumor progression.

  12. The UV (IUE) spectrum of the planetary nebula PC 11 (HD 149427)

    NARCIS (Netherlands)

    Parthasarathy, M; Garcia-Lario, P; Pottasch, [No Value; de Martino, D; Surendiranath, R

    The UV spectrum of PC 11 is found to show variations in the strength of the O III] 1666 Angstrom, N III] 1750 Angstrom and C III] 1909 Angstrom emission lines. The detection of continuum emission in the wavelength interval 2650 Angstrom to 3200 Angstrom indicates that the central star of PC 11 has

  13. The single-strand DNA binding activity of human PC4 preventsmutagenesis and killing by oxidative DNA damage

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jen-Yeu; Sarker, Altaf Hossain; Cooper, Priscilla K.; Volkert, Michael R.

    2004-02-01

    Human positive cofactor 4 (PC4) is a transcriptional coactivator with a highly conserved single-strand DNA (ssDNA) binding domain of unknown function. We identified PC4 as a suppressor of the oxidative mutator phenotype of the Escherichia coli fpg mutY mutant and demonstrate that this suppression requires its ssDNA binding activity. Yeast mutants lacking their PC4 ortholog Sub1 are sensitive to hydrogen peroxide and exhibit spontaneous and peroxide induced hypermutability. PC4 expression suppresses the peroxide sensitivity of the yeast sub l{Delta} mutant, suggesting that the human protein has a similar function. A role for yeast and human proteins in DNA repair is suggested by the demonstration that Sub1 acts in a peroxide-resistance pathway involving Rad2 and by the physical interaction of PC4 with the human Rad2 homolog XPG. We show XPG recruits PC4 to a bubble-containing DNA substrate with resulting displacement of XPG and formation of a PC4-DNA complex. We discuss the possible requirement for PC4 in either global or transcription-coupled repair of oxidative DNA damage to mediate the release of XPG bound to its substrate.

  14. Operational Implementation of a Pc Uncertainty Construct for Conjunction Assessment Risk Analysis

    Science.gov (United States)

    Newman, Lauri K.; Hejduk, Matthew D.; Johnson, Lauren C.

    2016-01-01

    Earlier this year the NASA Conjunction Assessment and Risk Analysis (CARA) project presented the theoretical and algorithmic aspects of a method to include the uncertainties in the calculation inputs when computing the probability of collision (Pc) between two space objects, principally uncertainties in the covariances and the hard-body radius. The output of this calculation approach is to produce rather than a single Pc value an entire probability density function that will represent the range of possible Pc values given the uncertainties in the inputs and bring CA risk analysis methodologies more in line with modern risk management theory. The present study provides results from the exercise of this method against an extended dataset of satellite conjunctions in order to determine the effect of its use on the evaluation of conjunction assessment (CA) event risk posture. The effects are found to be considerable: a good number of events are downgraded from or upgraded to a serious risk designation on the basis of consideration of the Pc uncertainty. The findings counsel the integration of the developed methods into NASA CA operations.

  15. Structure of the polycystic kidney disease TRP channel Polycystin-2 (PC2).

    Science.gov (United States)

    Grieben, Mariana; Pike, Ashley C W; Shintre, Chitra A; Venturi, Elisa; El-Ajouz, Sam; Tessitore, Annamaria; Shrestha, Leela; Mukhopadhyay, Shubhashish; Mahajan, Pravin; Chalk, Rod; Burgess-Brown, Nicola A; Sitsapesan, Rebecca; Huiskonen, Juha T; Carpenter, Elisabeth P

    2017-02-01

    Mutations in either polycystin-1 (PC1 or PKD1) or polycystin-2 (PC2, PKD2 or TRPP1) cause autosomal-dominant polycystic kidney disease (ADPKD) through unknown mechanisms. Here we present the structure of human PC2 in a closed conformation, solved by electron cryomicroscopy at 4.2-Å resolution. The structure reveals a novel polycystin-specific 'tetragonal opening for polycystins' (TOP) domain tightly bound to the top of a classic transient receptor potential (TRP) channel structure. The TOP domain is formed from two extensions to the voltage-sensor-like domain (VSLD); it covers the channel's endoplasmic reticulum lumen or extracellular surface and encloses an upper vestibule, above the pore filter, without blocking the ion-conduction pathway. The TOP-domain fold is conserved among the polycystins, including the homologous channel-like region of PC1, and is the site of a cluster of ADPKD-associated missense variants. Extensive contacts among the TOP-domain subunits, the pore and the VSLD provide ample scope for regulation through physical and chemical stimuli.

  16. Pregestational body mass index is related to neonatal abdominal circumference at birth--a Danish population-based study

    DEFF Research Database (Denmark)

    Tanvig, M; Wehberg, S; Vinter, C A

    2013-01-01

    OBJECTIVES: To examine the impact of maternal pregestational body mass index (BMI) and smoking on neonatal abdominal circumference (AC) and weight at birth. To define reference curves for birth AC and weight in offspring of healthy, nonsmoking, normal weight women. DESIGN: Population-based study....

  17. Antagonism in the extraction of uranium(VI) by the binary mixture of PC88A and benzimidazole

    International Nuclear Information System (INIS)

    Mukherjee, A.; Kamila, S.; Chakravortty, V.

    1999-01-01

    Extraction studies of uranium(VI) by the binary mixture of PC88A and benzimidazole show an antagonistic behavior in the concentration range 10 -5 -10 -6 M of PC88A and 0.005M of benzimidazole. Antagonism is observed due to the deprotonation of PC88A by benzimidazole forming an adduct resulting in the virtual removal of PC88A from the system. (author)

  18. Bursts of Pc 1-2 related to flux transfer events

    International Nuclear Information System (INIS)

    Arnoldy, R.L.; Cahill, L.J. Jr.; Engebretson, M.J.

    1987-01-01

    Instances of sporadic reconnection of geomagnetic and interplanetary magnetic field lines have been measured by space-craft passing through the dayside magnetopause region (Russell and Elphic 1979; Rijnbeek et al. 1984). The ionospheric signature of the reconnection events (flux transfer events) is a topic of current interest in that if one is evident then ground magnetic field data can be used to monitor the rate of dayside reconnection and conditions under which it occurs in a manner not possible with rapidly moving spacecraft. The proposed ground magnetic signature of a flux transfer event (FTE) is a large amplitude one-cycle Pc 5 (150-600 second period) pulse produced by a large vortex of ionospheric Hall current generated by the field-aligned current in the helical flux tube that has reconnected (Lee 1986). The intent of this article is to provide further data on the possible ground magnetic signatures of FTE (Lanzerotti el al. 1986) as measured by the induction antennas that the University of New Hampshire and the University of Minnesota have operated at high latitudes in the Antarctic and Greenland. With a high-frequency cut-off of 5 hertz, the induction magnetometers can measure Pc 1-2 waves (0.1-5.0 hertz) which cannot be seen by fluxgate instruments. Indeed, Pc 1-2 waves are frequently observed on the ground coincident with the Pc 5 FTE signature which provides some interesting new perspectives on these events

  19. Evaluation of thermodynamic properties of fluid mixtures by PC-SAFT model

    Energy Technology Data Exchange (ETDEWEB)

    Almasi, Mohammad, E-mail: m.almasi@khouzestan.srbiau.ac.ir

    2014-09-10

    Experimental and calculated partial molar volumes (V{sup ¯}{sub m,1}) of MIK with (♦) 2-PrOH, (♢) 2-BuOH, (●) 2-PenOH at T = 298.15 K. (—) PC-SAFT model. - Highlights: • Densities and viscosities of the mixtures (MIK + 2-alkanols) were measured. • PC-SAFT model was applied to correlate the volumetric properties of binary mixtures. • Agreement between experimental data and calculated values by PC-SAFT model is good. - Abstract: Densities and viscosities of binary mixtures of methyl isobutyl ketone (MIK) with polar solvents namely, 2-propanol, 2-butanol and 2-pentanol, were measured at 7 temperatures (293.15–323.15 K) over the entire range of composition. Using the experimental data, excess molar volumes V{sub m}{sup E}, isobaric thermal expansivity α{sub p}, partial molar volumes V{sup ¯}{sub m,i} and viscosity deviations Δη, have been calculated due to their importance in the study of specific molecular interactions. The observed negative and positive values of deviation/excess parameters were explained on the basis of the intermolecular interactions occur in these mixtures. The Perturbed Chain Statistical Association Fluid Theory (PC-SAFT) has been used to correlate the volumetric behavior of the mixtures.

  20. Pocket PC-based portable gamma-ray spectrometer

    Directory of Open Access Journals (Sweden)

    Kamontip Ploykrachang

    2011-04-01

    Full Text Available A portable gamma-ray spectrometer based on a Pocket PC has been developed. A 12-bit pipeline analog-to-digitalconverter (ADC associated with an implemented pulse height histogram function on field programmable gate array (FPGAoperating at 15 MHz is employed for pulse height analysis from built-in pulse amplifier. The system, which interfaces withthe Pocket PC via an enhanced RS-232 serial port under the microcontroller facilitation, is utilized for spectrum acquisition,display and analysis. The pulse height analysis capability of the system was tested and it was found that the ADC integralnonlinearity of ±0.45% was obtained with the throughput rate at 160 kcps. The overall system performance was tested usinga PIN photodiode-CsI(Tl crystal coupled scintillation detector and gamma standard radioactive sources of Cs-137 andCo-60. Low cost and the compact system size as a result of the implemented logical function are also discussed.

  1. On the robustness of EC-PC spike detection method for online neural recording.

    Science.gov (United States)

    Zhou, Yin; Wu, Tong; Rastegarnia, Amir; Guan, Cuntai; Keefer, Edward; Yang, Zhi

    2014-09-30

    Online spike detection is an important step to compress neural data and perform real-time neural information decoding. An unsupervised, automatic, yet robust signal processing is strongly desired, thus it can support a wide range of applications. We have developed a novel spike detection algorithm called "exponential component-polynomial component" (EC-PC) spike detection. We firstly evaluate the robustness of the EC-PC spike detector under different firing rates and SNRs. Secondly, we show that the detection Precision can be quantitatively derived without requiring additional user input parameters. We have realized the algorithm (including training) into a 0.13 μm CMOS chip, where an unsupervised, nonparametric operation has been demonstrated. Both simulated data and real data are used to evaluate the method under different firing rates (FRs), SNRs. The results show that the EC-PC spike detector is the most robust in comparison with some popular detectors. Moreover, the EC-PC detector can track changes in the background noise due to the ability to re-estimate the neural data distribution. Both real and synthesized data have been used for testing the proposed algorithm in comparison with other methods, including the absolute thresholding detector (AT), median absolute deviation detector (MAD), nonlinear energy operator detector (NEO), and continuous wavelet detector (CWD). Comparative testing results reveals that the EP-PC detection algorithm performs better than the other algorithms regardless of recording conditions. The EC-PC spike detector can be considered as an unsupervised and robust online spike detection. It is also suitable for hardware implementation. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Waist circumference, body mass index, and employment outcomes.

    Science.gov (United States)

    Kinge, Jonas Minet

    2017-07-01

    Body mass index (BMI) is an imperfect measure of body fat. Recent studies provide evidence in favor of replacing BMI with waist circumference (WC). Hence, I investigated whether or not the association between fat mass and employment status vary by anthropometric measures. I used 15 rounds of the Health Survey for England (1998-2013), which has measures of employment status in addition to measured height, weight, and WC. WC and BMI were entered as continuous variables and obesity as binary variables defined using both WC and BMI. I used multivariate models controlling for a set of covariates. The association of WC with employment was of greater magnitude than the association between BMI and employment. I reran the analysis using conventional instrumental variables methods. The IV models showed significant impacts of obesity on employment; however, they were not more pronounced when WC was used to measure obesity, compared to BMI. This means that, in the IV models, the impact of fat mass on employment did not depend on the measure of fat mass.

  3. Development of a PC code package for the analysis of research and power reactors

    International Nuclear Information System (INIS)

    Urli, N.

    1992-06-01

    Computer codes available for performing reactor physics calculations for nuclear research reactors and power reactors are normally suited for running on mainframe computers. With the fast development in speed and memory of the PCs and affordable prices it became feasible to develop PC versions of commonly used codes. The present work performed under an IAEA sponsored research contract has successfully developed a code package for running on a PC. This package includes a cross-section generating code PSU-LEOPARD and 2D and 1D spatial diffusion codes, MCRAC and MCYC 1D. For adapting PSU-LEOPARD for a PC, the binary library has been reorganized to decimal form, upgraded to FORTRAN-77 standard and arrays and subroutines reorganized to conform to PC compiler. Similarly PC version of MCRAC for FORTRAN-77 and 1D code MCYC 1D have been developed. Tests, verification and bench mark results show excellent agreement with the results obtained from mainframe calculations. The execution speeds are also very satisfactory. 12 refs, 4 figs, 3 tabs

  4. LysoPC and PAF Trigger Arachidonic Acid Release by Divergent Signaling Mechanisms in Monocytes

    Directory of Open Access Journals (Sweden)

    Janne Oestvang

    2011-01-01

    Full Text Available Oxidized low-density lipoproteins (LDLs play an important role during the development of atherosclerosis characterized by intimal inflammation and macrophage accumulation. A key component of LDL is lysophosphatidylcholine (lysoPC. LysoPC is a strong proinflammatory mediator, and its mechanism is uncertain, but it has been suggested to be mediated via the platelet activating factor (PAF receptor. Here, we report that PAF triggers a pertussis toxin- (PTX- sensitive intracellular signaling pathway leading to sequential activation of sPLA2, PLD, cPLA2, and AA release in human-derived monocytes. In contrast, lysoPC initiates two signaling pathways, one sequentially activating PLD and cPLA2, and a second parallel PTX-sensitive pathway activating cPLA2 with concomitant activation of sPLA2, all leading to AA release. In conclusion, lysoPC and PAF stimulate AA release by divergent pathways suggesting involvement of independent receptors. Elucidation of monocyte lysoPC-specific signaling mechanisms will aid in the development of novel strategies for atherosclerosis prevention, diagnosis, and therapy.

  5. Clinical utility of calf front hoof circumference and maternal intrapelvic area in predicting dystocia in 103 late gestation Holstein-Friesian heifers and cows.

    Science.gov (United States)

    Hiew, Mark W H; Megahed, Ameer A; Townsend, Jonathan R; Singleton, Wayne L; Constable, Peter D

    2016-02-01

    The objective of this study was to determine the clinical utility of measuring calf front hoof circumference, maternal intrapelvic area, and selected morphometric values in predicting dystocia in dairy cattle. An observational study using a convenience sample of 103 late-gestation Holstein-Friesian heifers and cows was performed. Intrapelvic height and width of the dam were measured using a pelvimeter, and the intrapelvic area was calculated. Calf front hoof circumference and birth weight were also measured. Data were analyzed using Spearman's correlation coefficient (rs), Mann-Whitney U test, and binary or ordered logistic regression; P dystocia (calving difficulty score = 4 or 5), with sensitivity = 0.50 and specificity = 0.93 at the optimal cutpoint for the ratio (>0.068 cm/cm(2)). Determining the ratio of calf front hoof circumference to maternal intrapelvic area has clinical utility in predicting the calving difficulty score in Holstein-Friesian cattle. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Design of multichannel counting system-2 for IBM PC and compatibles

    International Nuclear Information System (INIS)

    Ahmad, Z.; Qamer, R.; Mushtaq, N.

    2001-04-01

    A multichannel, Counting System 2 (MCCS-2) data acquisition plug-in card for the IBM ISA, MCA and EISA bus architecture has been designed and developed for acquisition of pulsed signal. The card features large dynamic range is achieved with the help of 16-bit pulse counters, fast signal acquisition and a self-testing capability in a single slot card. The MCCS-2 (designed by R and D group, CD) is an upgraded version of MCCS-1 [6]. The MCCS-2 consists of a plug-in interface card (MCCS-PC) for IBM PC and compatibles and a BNC terminal module (MCCS-BNC). The MCCS-PC is address selectable and can simultaneous monitoring ten independent SCA inputs. An on board programmable timer provides elapsed time measurement. A menu-driven software program is developed for data acquisition and timer control. (author)

  7. Trending in Pc Measurements via a Bayesian Zero-Inflated Mixed Model

    Science.gov (United States)

    Vallejo, Jonathon; Hejduk, Matthew; Stamey, James

    2015-01-01

    Two satellites predicted to come within close proximity of one another, usually a high-value satellite and a piece of space debris moving the active satellite is a means of reducing collision risk but reduces satellite lifetime, perturbs satellite mission, and introduces its own risks. So important to get a good statement of the risk of collision in order to determine whether a maneuver is truly necessary. Two aspects of this Calculation of the Probability of Collision (Pc) based on the most recent set of position velocity and uncertainty data for both satellites. Examination of the changes in the Pc value as the event develops. Events should follow a canonical development (Pc vs time to closest approach (TCA)). Helpful to be able to guess where the present data point fits in the canonical development in order to guide operational response.

  8. A embedded Linux system based on PowerPC

    International Nuclear Information System (INIS)

    Ye Mei; Zhao Jingwei; Chu Yuanping

    2006-01-01

    The authors will introduce a Embedded Linux System based on PowerPC as well as the base method on how to establish the system. The goal of the system is to build a test system of VMEbus device. It also can be used to setup the small data acquisition and control system. Two types of compiler are provided by the developer system according to the features of the system and the Power PC. At the top of the article some typical embedded Operation system will be introduced and the features of different system will be provided. And then the method on how to build a embedded Linux system as well as the key technique will be discussed in detail. Finally a successful read-write example will be given based on the test system. (authors)

  9. Bone scintigraphy in evaluating the viability of composite bone grafts revascularized by microvascular anastomoses, conventional autogenous bone grafts, and free non-revascularized periosteal grafts

    International Nuclear Information System (INIS)

    Berggren, A.; Weiland, A.J.; Ostrup, L.T.

    1982-01-01

    Researchers studied the value of bone scintigraphy in the assessment of anastomotic patency and bone-cell viability in free bone grafts revascularized by microvascular anastomoses in twenty-seven dogs. The dogs were divided into three different groups, and scintigraphy was carried out using technetium-labeled methylene diphosphonate in composite bone grafts revascularized by microvascular anastomoses, conventional autogenous bone grafts, and periosteal grafts placed in different recipient beds. The viability of the grafts were evaluated by histological examination and fluorescence microscopy after triple labeling with oxytetracycline on the first postoperative day, alizarin complexone on the fourth postoperative day, and DCAF on the eleventh postoperative day. A positive scintiscan within the first week following surgery indicated patent microvascular anastomoses, and histological study and fluorescence microscopy confirmed that bone throughout the graft was viable. A positive scintiscan one week after surgery or later does not necessarily indicate microvascular patency or bone-cell survival, because new bone formed by creeping substitution on the surface of a dead bone graft can result in this finding

  10. NGF-mediated transcriptional targets of p53 in PC12 neuronal differentiation

    Directory of Open Access Journals (Sweden)

    Labhart Paul

    2007-05-01

    Full Text Available Abstract Background p53 is recognized as a critical regulator of the cell cycle and apoptosis. Mounting evidence also suggests a role for p53 in differentiation of cells including neuronal precursors. We studied the transcriptional role of p53 during nerve growth factor-induced differentiation of the PC12 line into neuron-like cells. We hypothesized that p53 contributed to PC12 differentiation through the regulation of gene targets distinct from its known transcriptional targets for apoptosis or DNA repair. Results Using a genome-wide chromatin immunoprecipitation cloning technique, we identified and validated 14 novel p53-regulated genes following NGF treatment. The data show p53 protein was transcriptionally activated and contributed to NGF-mediated neurite outgrowth during differentiation of PC12 cells. Furthermore, we describe stimulus-specific regulation of a subset of these target genes by p53. The most salient differentiation-relevant target genes included wnt7b involved in dendritic extension and the tfcp2l4/grhl3 grainyhead homolog implicated in ectodermal development. Additional targets included brk, sdk2, sesn3, txnl2, dusp5, pon3, lect1, pkcbpb15 and other genes. Conclusion Within the PC12 neuronal context, putative p53-occupied genomic loci spanned the entire Rattus norvegicus genome upon NGF treatment. We conclude that receptor-mediated p53 transcriptional activity is involved in PC12 differentiation and may suggest a contributory role for p53 in neuronal development.

  11. Software Reviews. PC Software for Artificial Intelligence Applications.

    Science.gov (United States)

    Epp, Helmut; And Others

    1988-01-01

    Contrasts artificial intelligence and conventional programming languages. Reviews Personal Consultant Plus, Smalltalk/V, and Nexpert Object, which are PC-based products inspired by problem-solving paradigms. Provides information on background and operation of each. (RT)

  12. 2010 ME70 Workshop (PC1003, EK60)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The third leg of the 2010 SEAMAP Reeffish Survey, PC 1003, was originally scheduled as an experimental multibeam sonar workshop. However, on July 12, 2010, FSV...

  13. (PC) tablet penetration among undergraduate students of University ...

    African Journals Online (AJOL)

    Random sampling technique was adopted to select 200 students from ... The findings of the study revealed that PC tablet is a learning tool as students easily view ... computer, information and communication technology, mobile technologies ...

  14. Amniotic Fluid Arginine from Gestational Weeks 13 to 15 Is a Predictor of Birth Weight, Length, and Head Circumference

    Directory of Open Access Journals (Sweden)

    Astrid Bjørke-Jenssen

    2017-12-01

    Full Text Available Arginine is a constituent of proteins and a precursor for polyamines and nitric oxide, and is essential for placentation, angiogenesis, and growth. Maternal plasma arginine concentrations are found to be lower in pregnancies complicated by fetal growth restriction, and arginine supplementation in later pregnancy is reported to increase birth weight. We measured arginine and the metabolites asymmetric dimethylarginine (ADMA and symmetric dimethylarginine (SDMA in the amniotic fluid obtained in pregnancy weeks 13 to 15 from 363 pregnancies with a documented normal outcome and related the concentrations to birth weight, length, and head circumference. Arginine was higher in the amniotic fluid from female (mean 40.8 (SD 10.6 µmol/L compared to male fetuses (37.4 (SD 11.2 µmol/L, p = 0.003. Despite the gender difference, arginine in the amniotic fluid from gestational weeks 13–15 was the strongest predictor for birth weight, length, and head circumference. ADMA was a strong predictor for birth weight and length, SDMA for birth weight, while Arg/ADMA and Arg/SDMA only predicted head circumference in multiple linear regression models. Due to increased arginine demands, pregnancy is considered a state of relative arginine deficiency. Our findings reflect the importance of a good maternal arginine status in early pregnancy, an observation that should be evaluated in an intervention study.

  15. Short children with a low midupper arm circumference respond to food supplementation

    DEFF Research Database (Denmark)

    Fabiansen, Christian; Phelan, Kevin P Q; Cichon, Bernardette

    2016-01-01

    BACKGROUND: The management of children with moderate acute malnutrition (MAM) is based on food supplementation in outpatient programs. When midupper arm circumference (MUAC) is used as the sole admission criterion, it is common practice to exclude children with lengths .... The WHO calls for research to determine the treatment effect among children with MAM included by MUAC and aged ≥6 mo with lengths children given supplementary feeding based on an MUAC of 115-124 mm as the sole criterion, there would be no difference in growth...... rate between children Children aged 6-23 mo were included...

  16. No meaningful association of neighborhood food store availability with dietary intake, body mass index, or waist circumference in young Japanese women.

    Science.gov (United States)

    Murakami, Kentaro; Sasaki, Satoshi; Takahashi, Yoshiko; Uenishi, Kazuhiro

    2010-08-01

    The affordability of food is considered as an important factor influencing people's diet and hence health status. The objective of this cross-sectional study was to test the hypothesis that neighborhood food store availability is associated with some aspects of dietary intake and thus possibly with body mass index (BMI) and waist circumference in young Japanese women. Subjects were 989 female Japanese dietetic students 18 to 22 years of age. Neighborhood food store availability was defined as the number of food stores within a 0.5-mile (0.8-km) radius of residence (meat stores, fish stores, fruit and vegetable stores, confectionery stores/bakeries, rice stores, convenience stores, and supermarkets/grocery stores). Dietary intake was estimated using a validated, comprehensive self-administered diet history questionnaire. No association was seen between any measure of neighborhood food store availability and dietary intake, except for a positive association between confectionery and bread availability (based on confectionery stores/bakeries, convenience stores, and supermarkets/grocery stores) and intake of these items (P for trend = .02). Further, no association was seen for BMI or waist circumference, except for an inverse relationship between availability of convenience stores and BMI and a positive relationship between store availability for meat (meat stores and supermarkets/grocery stores) and fish (fish stores and supermarkets/grocery stores) and waist circumference. In conclusion, this study of young Japanese women found no meaningful association between neighborhood food store availability and dietary intake, BMI, or waist circumference, with the exception of a positive relationship between availability and intake for confectionery and bread. Copyright © 2010 Elsevier Inc. All rights reserved.

  17. PC-ECONPACK Version 3.0 Users Manual.

    Science.gov (United States)

    1991-11-01

    for inclusi on in cost sensitivity analysis UPDer Limit of the Change (%). PC-ECONPACK varies all the stipulated expense items both in an upward...Assumptions as stated in the Assumptions text information block. This section is used to discuss why certain alternatives were selected for inclusi ,n in the

  18. Desktop Publishing in a PC-Based Environment.

    Science.gov (United States)

    Sims, Harold A.

    1987-01-01

    Identifies, considers, and interrelates the functionality of hardware, firmware, and software types; discusses the relationship of input and output devices in the PC-based desktop publishing environment; and reports some of what has been experienced in three years of working intensively in/with desktop publishing devices and solutions. (MES)

  19. A PC based thin film dosimeter system

    DEFF Research Database (Denmark)

    Miller, A.; Hargittai, P.; Kovacs, A.

    2000-01-01

    A dosimeter system based on the Riso B3 dosimeter film, an office scanner for use with PC and the associated software is presented. The scanned image is analyzed either with standard software (Paint Shop Pro 5 or Excel) functions or with the computer code "Scanalizer" that allows presentation...

  20. Application of PC-SAFT to glycol containing systems - PC-SAFT towards a predictive approach

    DEFF Research Database (Denmark)

    Grenner, Andreas; Kontogeorgis, Georgios; von Solms, Nicolas

    2007-01-01

    for estimating pure compound parameters from low molecular weight data and extrapolate to complex compounds. For associating compounds this is not trivial since the two parameters for association (association energy and association volume) need to be fixed for a group. In this work, which focuses on glycols, new...... general pure compound parameters were obtained for PC-SAFT which are able to perform well for both vapor-liquid equilibria (VLE) and liquid-liquid equilibria (LLE). Linear trends of non-association parameters were obtained with respect to the molar mass. However, identical values for the association...

  1. PC-Link historical data base system MODCOMP/IBM at link for neutral particle beam operation

    International Nuclear Information System (INIS)

    Thurgood, P.

    1989-12-01

    ''PC-Link'' is a combination of hardware and software that connects an IBM PC/AT to a MODCOMP minicomputer. It is designed as an aid to the Neutral Beam operations coordinator during injection into the DIII-D tokamak project. An IBM PC/AT is linked to 4 MODCOMP ''realtime'' acquisition systems, each of which controls 2 neutral particle beam sources. At various points in the shot sequence, data is sent to the IBM PC/AT. This data can then be integrated with the data from the other sources into tables or graphics displays for use by the Beam Coordinator. In this way, the coordinator gets realtime feedback on the relative settings and performance of the sources and can observe trends within a particular source at one location. The PC- Link is used for observing relative timing information and for post shot historical archiving. The concept of the PC-Link was originally proposed several years ago. In April 1988, in-house implementation of the link software was begun. The PC-Link receives approximately 2 Kbytes of data per source per shot. This data is converted from MODCOMP format to IBM PC format and archived to disk. The last 280 shots per source are stored to disk to observe trends. The data can be displayed in a number of formats depending upon the situation. For example, prior to a shot, the beam MODCOMPs are sent timing information from the DIII-D tokamak control system. This data is echoed on the PC in a graphical representation displaying all 8 sources. At the end of the shot, the actual running times are displayed along with the requested settings. Any subset of the Historical data may be displayed either graphically or in tables for realtime comparisons between sources. This system is designed for realtime use, not for complete archiving purposes. This same data is also sent to a VAX computer for full integration into the archive database. This system is easily upgradable and extremely versatile. 4 figs

  2. Effect of cuprous halide interlayers on the device performance of ZnPc/C60 organic solar cells

    International Nuclear Information System (INIS)

    Lee, Jinho; Park, Dasom; Heo, Ilsu; Yim, Sanggyu

    2014-01-01

    Highlights: • Effect of CuX interlayers on subsequently deposited films and devices was studied. • CuI is the most effective for the performance of ZnPc/C 60 -based solar cells. • Results were related to the molecular geometry of ZnPc and HOMO level of interlayers. - Abstract: The effect of various cuprous halide (CuX) interlayers introduced between a poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) layer and zinc phthalocyanine (ZnPc) layer on the physical properties of the ZnPc thin films and device performances of ZnPc/C 60 -based small-molecule organic solar cells was studied. Strong substrate–molecule interaction between the CuX and ZnPc partly converted surface-perpendicular stacking geometry of ZnPc molecules into surface-parallel one. This flat-lying geometry led to an enhancement in electronic absorption and charge transport within the ZnPc films. As a result, the overall power conversion efficiency of the cell with CuI interlayer increased by ∼37%. In the case of the cells with CuBr and CuCl interlayer, however, the enhancement in device performances was limited because of the reduced conversion of the molecular geometry and increased energy barrier for hole extraction due to the low highest occupied molecular orbital level of the interlayer

  3. Plasma Cell Alloantigen 1 and IL-10 Secretion Define Two Distinct Peritoneal B1a B Cell Subsets With Opposite Functions, PC1high Cells Being Protective and PC1low Cells Harmful for the Growing Fetus

    Directory of Open Access Journals (Sweden)

    Anne Schumacher

    2018-05-01

    Full Text Available B cells possess various immuno regulatory functions. However, research about their participation in tolerance induction toward the fetus is just emerging. Accumulating evidence supports the idea that B cells can play seemingly conflicting roles during pregnancy, either protecting or harming the fetus. Previous findings indicated the presence of two different peritoneal B cell subsets, defined by the expression of the plasma cell alloantigen 1 (PC1 and with distinct immune modulatory functions. Here, we aimed to study the participation of these two B cell subsets, on pregnancy outcome in a murine model of disturbed fetal tolerance. The frequencies and cell numbers of peritoneal and splenic CD19+IL-10+ and CD19+CD5+IL-10+PC1+ cells were assessed in virgin as well as normal pregnant (NP and abortion-prone (AP females during the course of gestation. Peritoneal PC1low or PC1high B1a B cells were sorted, analyzed for their ability to secrete IL-10 and adoptively transferred into NP or AP females. On gestation day (gd 12, the abortion rate as well as the frequencies and cell numbers of regulatory T cells, TH1 and TH17 cells were determined in spleens and decidua. In addition, mRNA expression of IL-10, TGF-β, IFN-γ, and TNF-α was analyzed in decidual tissue. Peritoneal CD19+IL-10+ and CD19+CD5+IL-10+PC1+ frequencies fluctuated during the progression of normal pregnancies while no significant changes were observed in spleen. AP females showed significantly reduced frequencies of both B cell populations and exhibited an altered peritoneal PC1high/PC1low ratio at gd10. Adoptive transfers of PC1low B1a B cells into NP females increased the abortion rate in association with a reduced splenic regulatory T/TH17 ratio. By contrast, the transfer of PC1high B1a B cells into AP females significantly diminished the fetal rejection rate and significantly reduced the numbers of splenic TH17 cells. Our results suggest that the peritoneum harbors two distinct B1a B

  4. Weight-adjusted lean body mass and calf circumference are protective against obesity-associated insulin resistance and metabolic abnormalities

    Directory of Open Access Journals (Sweden)

    Toshinari Takamura

    2017-07-01

    Interpretation: Weight-adjusted lean body mass and skeletal muscle area are protective against weight-associated insulin resistance and metabolic abnormalities. The calf circumference reflects lean body mass and may be useful as a protective marker against obesity-associated metabolic abnormalities.

  5. Site-dependent charge transfer at the Pt(111)-ZnPc interface and the effect of iodine

    International Nuclear Information System (INIS)

    Ahmadi, Sareh; Wojek, Bastian M.; Noël, Quentin; Göthelid, Mats; Agnarsson, Björn; Bidermane, Ieva; Sun, Chenghua

    2014-01-01

    The electronic structure of ZnPc, from sub-monolayers to thick films, on bare and iodated Pt(111) is studied by means of X-ray photoelectron spectroscopy, X-ray absorption spectroscopy, and scanning tunneling microscopy. Our results suggest that at low coverage ZnPc lies almost parallel to the Pt(111) substrate, in a non-planar configuration induced by Zn-Pt attraction, leading to an inhomogeneous charge distribution within the molecule and an inhomogeneous charge transfer to the molecule. ZnPc does not form a complete monolayer on the Pt surface, due to a surface-mediated intermolecular repulsion. At higher coverage ZnPc adopts a tilted geometry, due to a reduced molecule-substrate interaction. Our photoemission results illustrate that ZnPc is practically decoupled from Pt, already from the second layer. Pre-deposition of iodine on Pt hinders the Zn-Pt attraction, leading to a non-distorted first layer ZnPc in contact with Pt(111)-I(√3×√3) or Pt(111)-I(√7×√7), and a more homogeneous charge distribution and charge transfer at the interface. On increased ZnPc thickness iodine is dissolved in the organic film where it acts as an electron acceptor dopant

  6. PrPC expression and prion seeding activity in the alimentary tract and lymphoid tissue of deer.

    Science.gov (United States)

    Davenport, Kristen A; Hoover, Clare E; Bian, Jifeng; Telling, Glenn C; Mathiason, Candace K; Hoover, Edward A

    2017-01-01

    The agent responsible for prion diseases is a misfolded form of a normal protein (PrPC). The prion hypothesis stipulates that PrPC must be present for the disease to manifest. Cervid populations across the world are infected with chronic wasting disease, a horizontally-transmissible prion disease that is likely spread via oral exposure to infectious prions (PrPCWD). Though PrPCWD has been identified in many tissues, there has been little effort to characterize the overall PrPC expression in cervids and its relationship to PrPCWD accumulation. We used immunohistochemistry (IHC), western blot and enzyme-linked immunosorbent assay to describe PrPC expression in naïve white-tailed deer. We used real-time, quaking-induced conversion (RT-QuIC) to detect prion seeding activity in CWD-infected deer. We assessed tissues comprising the alimentary tract, alimentary-associated lymphoid tissue and systemic lymphoid tissue from 5 naïve deer. PrPC was expressed in all tissues, though expression was often very low compared to the level in the CNS. IHC identified specific cell types wherein PrPC expression is very high. To compare the distribution of PrPC to PrPCWD, we examined 5 deer with advanced CWD infection. Using RT-QuIC, we detected prion seeding activity in all 21 tissues. In 3 subclinical deer sacrificed 4 months post-inoculation, we detected PrPCWD consistently in alimentary-associated lymphoid tissue, irregularly in alimentary tract tissues, and not at all in the brain. Contrary to our hypothesis that PrPC levels dictate prion accumulation, PrPC expression was higher in the lower gastrointestinal tissues than in the alimentary-associated lymphoid system and was higher in salivary glands than in the oropharyngeal lymphoid tissue. These data suggest that PrPC expression is not the sole driver of prion accumulation and that alimentary tract tissues accumulate prions before centrifugal spread from the brain occurs.

  7. An overview of the evaluation plan for PC/MISI: PC-based Multiple Information System Interface

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Lim, Bee Lee; Hall, Philip P.

    1985-01-01

    An initial evaluation plan for the personal computer multiple information system interface (PC/MISI) project is discussed. The document is intend to be used as a blueprint for the evaluation of this system. Each objective of the design project is discussed along with the evaluation parameters and methodology to be used in the evaluation of the implementation's achievement of those objectives. The potential of the system for research activities related to more general aspects of information retrieval is also discussed.

  8. Prognostic significance of the PC10 index for patients with stage II and III oesophageal cancer treated with radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sugahara, Shinji; Irie, Toshiyuki; Nozawa, Kumiko; Nakajima, Kotaro [Hitachi General Hospital, Ibaraki (Japan). Dept. of Radiology; Ohara, Kiyoshi; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Dept. of Radiology; Takahashi, Atsushi [Hitachi General Hospital, Ibaraki (Japan). Dept. of Pathology; Watanabe, Teruo [Tsukuba Univ., Ibaraki (Japan). Dept. of Pathology; Tanaka, Naomi [Tsukuba Univ., Ibaraki (Japan). Dept. of Internal Medicine

    1999-07-01

    The monoclonal antibody PC10 is used for immunohistochemical staining of the proliferating cell nuclear antigen (PCNA). The percentage of PC10-positive cancer cells is defined as the PC10 index. We evaluated the relationship between the PC10 index in pretreatment endoscopic biopsies and the prognoses of 47 patients with Stage II-III oesophageal squamous cell carcinoma treated with radiotherapy. The patients with a PC10 index >40% had significantly poorer prognoses than the other patients (p=0.0007). Proportional hazards model analysis indicated that only the PC10 index was a prognostic factor (p=0.0009). The patient group of complete responders showed significantly lower PC10 indices compared to patients with a partial response or no change (p=0.049). The PC10 index can be a good predictive indicator of the prognosis in patients with Stage II-III oesophageal cancer treated with radiotherapy. (orig.)

  9. INDXENDF: A PC code for indexing nuclear data files in ENDF-6 format

    International Nuclear Information System (INIS)

    Silva, O.O. de; Corcuera, R.P.; Ferreira, P.A.; Moraes Cunha, M. de.

    1992-01-01

    The PC code INDXENDF which creates visual or printed indexes of nuclear data files in ENDF-6 format, is available from the IAEA Nuclear Data Section on a PC diskette, free of charge upon request. The present document describes the features of this code. (author). 11 refs, 9 figs

  10. Human prostatic cancer cells, PC3, elaborate mitogenic activity which selectively stimulates human bone cells

    International Nuclear Information System (INIS)

    Perkel, V.S.; Mohan, S.; Herring, S.J.; Baylink, D.J.; Linkhart, T.A.

    1990-01-01

    Prostatic cancer typically produces osteoblastic metastases which are not attended by marrow fibrosis. In the present study we sought to test the hypothesis that prostatic cancer cells produce factor(s) which act selectively on human osteoblasts. Such a paracrine mechanism would explain the observed increase in osteoblasts, unaccompanied by an increase in marrow fibroblasts. To test this hypothesis we investigated the mitogenic activity released by the human prostatic tumor cell line, PC3. PC3 cells have been reported previously to produce mitogenic activity for cells that was relatively specific for rat osteoblasts compared to rat fibroblasts. However, the effects of this activity on human cells has not been examined previously. PC3-conditioned medium (CM) (5-50 micrograms CM protein/ml) stimulated human osteoblast proliferation by 200-950% yet did not stimulate human fibroblast proliferation ([3H]thymidine incorporation). PC3 CM also increased cell numbers in human osteoblast but not fibroblast cell cultures. To determine whether the osteoblast-specific mitogenic activity could be attributed to known bone growth factors, specific assays for these growth factors were performed. PC3 CM contained 10 pg insulin-like growth factor (IGF) I, less than 2 pg IGF II, 54 pg basic fibroblast growth factor, and 16 pg transforming growth factor beta/microgram CM protein. None of these growth factors alone or in combination could account for the observed osteoblast-specific PC3 cell-derived mitogenic activity. Furthermore, when 5 micrograms/ml PC3 CM was tested in combination with maximally effective concentrations of either basic fibroblast growth factor, IGF I, IGF II, or transforming growth factor beta, it produced an additive effect suggesting that PC3 CM stimulates osteoblast proliferation by a mechanism independent of these bone mitogens

  11. Optimal cut-off levels to define obesity: body mass index and waist circumference, and their relationship to cardiovascular disease, dyslipidaemia, hypertension and diabetes in Malaysia.

    Science.gov (United States)

    Zaher, Zaki Morad Mohd; Zambari, Robayaah; Pheng, Chan Siew; Muruga, Vadivale; Ng, Bernard; Appannah, Geeta; Onn, Lim Teck

    2009-01-01

    Many studies in Asia have demonstrated that Asian populations may require lower cut-off levels for body mass index (BMI) and waist circumference to define obesity and abdominal obesity respectively, compared to western populations. Optimal cut-off levels for body mass index and waist circumference were determined to assess the relationship between the two anthropometric- and cardiovascular indices. Receiver operating characteristics analysis was used to determine the optimal cut-off levels. The study sample included 1833 subjects (mean age of 44+/-14 years) from 93 primary care clinics in Malaysia. Eight hundred and seventy two of the subjects were men and 960 were women. The optimal body mass index cut-off values predicting dyslipidaemia, hypertension, diabetes mellitus, or at least one cardiovascular risk factor varied from 23.5 to 25.5 kg/m2 in men and 24.9 to 27.4 kg/m2 in women. As for waist circumference, the optimal cut-off values varied from 83 to 92 cm in men and from 83 to 88 cm in women. The optimal cut-off values from our study showed that body mass index of 23.5 kg/m2 in men and 24.9 kg/m2 in women and waist circumference of 83 cm in men and women may be more suitable for defining the criteria for overweight or obesity among adults in Malaysia. Waist circumference may be a better indicator for the prediction of obesity-related cardiovascular risk factors in men and women compared to BMI. Further investigation using a bigger sample size in Asia needs to be done to confirm our findings.

  12. Higher Household Income and the Availability of Electronic Devices and Transport at Home Are Associated with Higher Waist Circumference in Colombian Children: The ACFIES Study

    Directory of Open Access Journals (Sweden)

    Diego Gómez-Arbeláez

    2014-02-01

    Full Text Available Background: The current “epidemic” of childhood obesity is described as being driven by modern lifestyles with associated socioeconomic and environmental changes that modify dietary habits, discourage physical activity and encourage sedentary behaviors. Objective: To evaluate the association between household income and the availability of electronic devices and transport at home, and the values of waist circumference (WC, as an indicator of abdominal obesity, in children and adolescents from Bucaramanga, Colombia. Methods: Cross-sectional study of public elementary and high school population, of low-middle socioeconomic status. Results: A total of 668 schoolchildren were recruited. After adjusting for potential confounders, significant positive associations between waist circumference and higher household income (p = 0.011, and waist circumference and the availability of electronic devices and transport at home (p = 0.026 were found. Conclusions: In low-middle socioeconomic status schoolchildren in a developing country, those from relatively more affluent families had greater waist circumference, an association that is opposite to that observed in developed countries. This finding could be related to higher income family’s ability to purchase electronic devices and motorized transport which discourage physical activity and for their children to buy desirable and more costly western fast food.

  13. The reactor physics computer programs in PC's era

    International Nuclear Information System (INIS)

    Nainer, O.; Serghiuta, D.

    1995-01-01

    The main objective of reactor physics analysis is the evaluation of flux and power distribution over the reactor core. For CANDU reactors sophisticated computer programs, such as FMDP and RFSP, were developed 20 years ago for mainframe computers. These programs were adapted to work on workstations with UNIX or DOS, but they lack a feature that could improve their use and that is 'user friendly'. For using these programs the users need to deal with a great amount of information contained in sophisticated files. To modify a model is a great challenge. First of all, it is necessary to bear in mind all the geometrical dimensions and accordingly, to modify the core model to match the new requirements. All this must be done in a line input file. For a DOS platform, using an average performance PC system, could it be possible: to represent and modify all the geometrical and physical parameters in a meaningful way, on screen, using an intuitive graphic user interface; to reduce the real time elapsed in order to perform complex fuel-management analysis 'at home'; to avoid the rewrite of the mainframe version of the program? The author's answer is a fuel-management computer package operating on PC, 3 time faster than on a CDC-Cyber 830 mainframe one (486DX/33MHz/8MbRAM) or 20 time faster (Pentium-PC), respectively. (author). 5 refs., 1 tab., 5 figs

  14. Electrochemistry and spectroelectrochemistry of tert-butylcalix[4]arene bridged bis double-decker lutetium(III) phthalocyanine, Lu{sub 2}Pc{sub 4} and dimeric lutetium(III) phthalocyanine, Lu{sub 2}Pc{sub 2}(OAc){sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Koca, Atif [Chemical Engineering Department, Engineering Faculty, Marmara University, TR34722 Goeztepe, Istanbul (Turkey); Ceyhan, Tanju; Erbil, Mehmet K. [Department of Biochemistry, Division of Organic Chemistry, Guelhane Medical Academy (GATA), Ankara (Turkey); Ozkaya, Ali Riza [Department of Chemistry, Marmara University, TR34722 Goeztepe, Istanbul (Turkey)], E-mail: aliozkaya@marmara.edu.tr; Bekaroglu, Ozer [Department of Chemistry, Technical University of Istanbul, TR34469 Maslak, Istanbul (Turkey)], E-mail: obek@itu.edu.tr

    2007-11-09

    In this study, electrochemical, electrochromic and spectroelectrochemical properties of a tert-butylcalix[4]arene bridged bis double-decker lutetium(III) phthalocyanine (Lu{sub 2}Pc{sub 4}2) were investigated explicitly as compared with a tert-butylcalix[4]arene bridged dimeric lutetium(III) phthalocyanine [Lu{sub 2}Pc{sub 2}(OAc){sub 2}1]. Distinctive differences between electrochemical and electrochromic properties of 1 and 2 were detected. Moreover, the properties of 1 and 2 were compared with previously reported S{sub 4}(CH{sub 2}){sub 4} bridged Lu{sub 2}Pc{sub 2}(OAc){sub 2} and Lu{sub 2}Pc{sub 4}. The calixarene bridged phthalocyanine (Pc) compounds, 1 and 2 showed well-defined electrochromic behaviour with green-blue and blue-purple colour transitions. The enhanced electrochromic properties of 2, as compared to 1, were attributed to its double-decker structure, probably allowing the formation of suitable ion channels for the counter ion movement in the solid film.

  15. High-latitude Pc 1 bursts arising in the dayside boundary layer region

    International Nuclear Information System (INIS)

    Hansen, H.J.; Fraser, B.J.; Menk, F.W.; Hu, Y.D.; Newell, P.T.; Meng, C.I.; Morris, R.J.

    1992-01-01

    Dayside Pc 1 geomagnetic pulsation bursts have been studied using a three-station array of induction magnetometers located at high latitudes. Associated magnetic variations in the form of solitary pulses often lead the Pc 1 bursts by 1 to 2 min. These pulses are typically associated with riometer absorption events and consequently the precipitation of fluxes of keV electrons. The Pc 1 bursts are interpreted as resulting from ion cyclotron waves which have propagated to the ionosphere from the equatorial boundary layer region. The associated boundary layer ions, identified by the low-altitude DMSP F7 satellite, range between 1 and 5 keV in energy. These particles are considered to be the most likely free energy source for the ion cyclotron waves. It is considered that such resonant ions enter the magnetosphere via the cleft and cusp because this enables a prenoon time of occurrence of most of the observations to be explained. Measured time delays of 40 to 120 s between the associated riometer absorption and Pc 2 bursts are consistent with an ion cyclotron wave generations region located in the equatorial magnetosphere

  16. Waist circumference threshold values for type 2 diabetes risk.

    Science.gov (United States)

    Friedl, Karl E

    2009-07-01

    Adult gains in body weight, excess adiposity, and intra-abdominal fat have each been associated with risk for type 2 diabetes mellitus (T2DM), forming the basis for preventive medicine guidelines and actuarial predictions using practical indices of weight (e.g., body mass index [BMI]) and waist circumference (WC). As obesity-related disease spreads beyond affluent western countries, application of WC thresholds to other populations has highlighted issues of their generalizability. For example, U.S. national health goals based on BMI technology has provided many great insights into disease, including modern imaging technologies that have differentiated fat depots that have the greatest influence on T2DM, but ultimately, an inexpensive measuring tape provides the most useful and cost-effective preventive measure for T2DM today. At some point in the future, a Star Trek-like abdominal body fat "tricorder" noninvasive assessment of tissue composition may provide an advantage over abdominal girth. Copyright 2009 Diabetes Technology Society.

  17. Assessing Factors Related to Waist Circumference and Obesity: Application of a Latent Variable Model

    OpenAIRE

    Dalvand, Sahar; Koohpayehzadeh, Jalil; Karimlou, Masoud; Asgari, Fereshteh; Rafei, Ali; Seifi, Behjat; Niksima, Seyed Hassan; Bakhshi, Enayatollah

    2015-01-01

    Background. Because the use of BMI (Body Mass Index) alone as a measure of adiposity has been criticized, in the present study our aim was to fit a latent variable model to simultaneously examine the factors that affect waist circumference (continuous outcome) and obesity (binary outcome) among Iranian adults. Methods. Data included 18,990 Iranian individuals aged 20–65 years that are derived from the third National Survey of Noncommunicable Diseases Risk Factors in Iran. Using latent variabl...

  18. Radioimmunoassay data processing program for IBM PC computers

    International Nuclear Information System (INIS)

    1989-06-01

    The Medical Applications Section of the International Atomic Energy Agency (IAEA) has previously developed several programs for use on the Hewlett-Packard HP-41C programmable calculator to facilitate better quality control in radioimmunoassay through improved data processing. The program described in this document is designed for off-line analysis using an IBM PC (or compatible) for counting data from standards and unknown specimens (i.e. for analysis of counting data previously recorded by a counter), together with internal quality control (IQC) data both within and between batch. The greater computing power of the IBM PC has enabled the imprecision profile and IQC control curves which were unavailable on the HP-41C version. It is intended that the program would make available good data processing capability to laboratories having limited financial resources and serious problems of quality control. 3 refs

  19. Dietary Energy Density in Relation to Subsequent Changes of Weight and Waist Circumference in European Men and Women

    NARCIS (Netherlands)

    Du, H.; Ginder, V.; Jebb, S.A.; Forouchi, N.G.; Wareham, N.; Halkjaer, J.; Tjonneland, A.; Overvad, K.; Jakobsen, M.U.; Buijsse, B.; Steffen, A.; Palli, D.; Masala, G.; Saris, W.H.; Sorensen, T.; Feskens, E.J.M.

    2009-01-01

    Background - Experimental studies show that a reduction in dietary energy density (ED) is associated with reduced energy intake and body weight. However, few observational studies have investigated the role of ED on long-term weight and waist circumference change. Methods and Principal Findings -

  20. General specifications for the development of a USL/DBMS NASA/PC R and D distributed workstation

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Chum, Frank Y.

    1984-01-01

    The general specifications for the development of a PC-based distributed workstation (PCDWS) for an information storage and retrieval systems environment are defined. This research proposes the development of a PCDWS prototype as part of the University of Southwestern Louisiana Data Base Management System (USL/DBMS) NASA/PC R and D project in the PC-based workstation environment.

  1. Consideration on extradosed prestressed concrete road bridge; Dorokyo ni okeru daihenshin PC keburu kyo

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, A.; Honma, A. [Japan Highway Public Corp., Tokyo (Japan)

    1997-03-31

    The details of the investigation on the Odawara Blue Way Bridge for which extradosed type is employed are provided, and a report is made about the situation of the study on the future construction of the 2nd Tomei-Meishin Expressway. The extradosed PC bridge is considered to have intermediate structural characteristics of those of the conventional beam bridge and PC cable stayed bridge, and is expected to be applied to bridges having approximately from 100 to 200m span. The features of the extradosed PC bridge is outlined. Approximately 1/35 beam height on the intermediate support and 1/10 main tower height against the center span are considered to be proper. PC steel products can be used efficiently because stress fluctuation of diagonals and the load sharing rate of the diagonal member are less than those of the PC cable stayed bridge and safety factor similar to that of general internal cable can be adopted. Construction works for the main tower and the diagonal member are easy due to low height of the main tower, and the bridge is advantageous also in the maintenance control because no beam is required. 5 refs., 8 figs., 2 tabs.

  2. A study of mid-arm and chest circumferences as predictors of low birthweight.

    Science.gov (United States)

    Rogo, K; Nyagudi, O; Ferguson, A

    1991-02-01

    Nine hundred ninety-nine newborns were examined in order to determine the relationship between birthweight and mid-arm and chest circumstances. An early neonatal mortality rate of 51/1000 was recorded, being much higher for preterm (301/1000) than term babies (2.5/1000). Both mid-arm and chest circumference showed highly significant correlations with birthweight (r = 0.872, P less than 0.0001 and r = 0.918, P less than 0.0001, respectively). The correlation between weight and chest circumstances was upheld even for very small babies.

  3. Changes in Waist Circumference and the Incidence of Acute Myocardial Infarction in Middle-Aged Men and Women

    DEFF Research Database (Denmark)

    Berentzen, Tina Landsvig; Jakobsen, Marianne Uhre; Stegger, Jakob Gerhard

    2011-01-01

    Waist circumference (WC) measured at one point in time is positively associated with the risk of acute myocardial infarction (MI), but the association with changes in WC (DWC) is not clear. We investigated the association between DWC and the risk of MI in middle-aged men and women, and evaluated...

  4. Electrical characterization of the ITO/NiPc/PEDOT : PSS junction diode

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Mutabar; Sayyad, M H; Karimov, Kh S; Wahab, Fazal, E-mail: mutabar_shah@hotmail.co, E-mail: mutabarshah@gmail.co [Ghulam Ishaq Khan Institute of Engineering Sciences and Technology, Topi, District Swabi, Khyber Pakhtunkhwa 23640 (Pakistan)

    2010-10-13

    This paper reports on the fabrication and characterization of an ITO/NiPc/PEDOT : PSS junction diode. A thin film of nickel phthalocyanine (NiPc) was deposited by the thermal vacuum deposition method on indium tin oxide (ITO) used as a substrate. The current-voltage characteristics of the diode were measured at room temperature under dark condition and showed rectifying behaviour. The values of several electrical parameters such as ideality factor, barrier height, conductivity, and series and shunt resistances were calculated.

  5. Can body mass index, waist circumference, waist-hip ratio and waist-height ratio predict the presence of multiple metabolic risk factors in Chinese subjects?

    Directory of Open Access Journals (Sweden)

    Lu Liping

    2011-01-01

    Full Text Available Abstract Background Obesity is associated with metabolic risk factors. Body mass index (BMI, waist circumference, waist-hip ratio (WHR and waist-height ratio (WHtR are used to predict the risk of obesity related diseases. However, it has not been examined whether these four indicators can detect the clustering of metabolic risk factors in Chinese subjects. Methods There are 772 Chinese subjects in the present study. Metabolic risk factors including high blood pressure, dyslipidemia, and glucose intolerance were identified according to the criteria from WHO. All statistical analyses were performed separately according to sex by using the SPSS 12.0. Results BMI, waist circumference and WHtR values were all significantly associated with blood pressure, glucose, triglyceride and also with the number of metabolic risk factors in both male and female subjects (all of P Conclusion The BMI, waist circumference and WHtR values can similarly predict the presence of multiple metabolic risk factors in Chinese subjects.

  6. Isoform 1 of TPD52 (PC-1) promotes neuroendocrine transdifferentiation in prostate cancer cells

    KAUST Repository

    Moritz, Tom; Venz, Simone; Junker, Heike; Kreuz, Sarah; Walther, Reinhard; Zimmermann, Uwe

    2016-01-01

    The tumour protein D52 isoform 1 (PC-1), a member of the tumour protein D52 (TPD52) protein family, is androgen-regulated and prostate-specific expressed. Previous studies confirmed that PC-1 contributes to malignant progression in prostate cancer

  7. IDGAM. A PC code and database to help nuclide identification in activation analysis

    International Nuclear Information System (INIS)

    Paviotti Corcuera, R.; Moraes Cunha, M. de; Jayanthi, K.A.

    1994-01-01

    The document describes a PC diskette containing a code and database which helps researchers to identify the nuclides in a radioactive sample. Data can be retrieved by gamma-ray energy, nuclide or element. The PC diskette is available, costfree, from the IAEA Nuclear Data Section, upon request. (author). 6 refs, 5 figs

  8. Got a call from "Microsoft"? The social way infecting your PC

    CERN Multimedia

    Computer Security Team

    2012-01-01

    Have you recently been called by “Microsoft Security”? At home!? Then beware: these are fake calls trying to make you install malicious software on your (home) PC!   This scam is currently prevalent throughout the Geneva area, targeting many different international organizations and companies. If you receive such a call, just ignore it and hang up. If you have fallen for this scam and followed their pleas, please contact us at Computer.Security@cern.ch. This kind of scam is called “Social Engineering”. Some “Microsoft” call-centre agent informs you that your PC is infected and will try to convince you to download some software from the web. If you do – BANG – your PC is compromized and your local data is at stake. In other Social Engineering scams, the attackers try to convince you to give them your password or sensitive documents. Thus, recall that the real Microsoft will never call you – and definite...

  9. A water-cooling solution for PC-racks of the LHC experiments

    CERN Document Server

    Vannerem, P

    2004-01-01

    With ever increasing power consumption and heat dissipation of todays CPUs, cooling of rack-mounted PCs is an issue for the future online farms of the LHC experiments. In order to investigate the viability of a water-cooling solution, a prototype PC-farm rack has been equipped with a commercially available retrofitted heat exchanger. The project has been carried out as a collaboration of the four LHC experiments and the PH-ESS group . This note reports on the results of a series of cooling and power measurements of the prototype rack with configurations of 30 to 48 PCs. The cooling performance of the rack-cooler is found to be adequate; it extracts the heat dissipated by the CPUs efficiently into the cooling water. Hence, the closed PC rack transfers almost no heat into the room. The measurements and the failure tests show that the rack-cooler concept is a viable solution for the future PC farms of the LHC experiments.

  10. COMBINE/PC - a portable neutron spectrum and cross-section generation program

    International Nuclear Information System (INIS)

    Nigg, D.W.; Grimesey, R.A.; Curtis, R.L.

    1990-01-01

    Use of personal computers and engineering workstations for complex scientific computations has expanded rapidly in the past few years. This trend is expected to continue in the future with the introduction of increasingly sophisticated microprocessors and microcomputer systems. In response to this, an integrated system of neutronics and radiation transport software suitable for operation in an IBM personal computer (PC)-class environment has been under development at the Idaho National Engineering Laboratory (INEL) for the past 3 years. A key component of this system will be module to produce application-specific multigroup cross-section libraries that can be used in various neutron transport and diffusion theory code modules. This software module, referred to as COMBINE/PC, was recently completed at INEL and is the subject of this paper. COMBINE/PC was developed to provide an ENDF/B-based neutron cross-section generation capability of sufficient sophistication to handle a wide variety of practical fission and fusion-related applications while maintaining a compact machine-independent structure

  11. CERN Physics Screen Saver: Help LHC tracking studies on your PC

    CERN Multimedia

    2004-01-01

    Many PC users are familiar with screensavers such as SETI@home and FightAIDS@home. These screensavers take advantage of times when your PC is idle to do useful computing on a particular scientific problem. SETI@home, which analyses radio-astronomy data for signs of extraterrestrial intelligence, has been downloaded by over 5 million people. Similar programs are now sold commercially, and installed in major corporations to provide extra computing power at low cost. CERN 's IT Department is interested in evaluating this sort of technology for the future. Most of the scientific computing challenges that the LHC experiments are facing will require access to large amounts of storage, and cannot be run on individual PCs. However, there are exceptions. A program called SixTrack, which simulates particles traveling around the LHC to study the stability of their orbits, can fit on a single PC and requires relatively little input or output. SixTrack, which was developed by Frank Schmidt of the AB Department, produces r...

  12. Independent and opposite associations of waist and hip circumferences with diabetes, hypertension and dyslipidemia : the AusDiab Study

    NARCIS (Netherlands)

    Snijder, M B; Zimmet, Paul Z; Visser, M; Dekker, J M; Seidell, J C; Shaw, Jonathan E

    OBJECTIVE: Fat distribution as measured by waist-to-hip ratio has been shown to be an important independent predictor of glucose intolerance. Few studies, however, have considered the contributions of the waist and hip circumferences independently. The aim of this study was to investigate the

  13. Independent and opposite associations of waist and hip circumferences with diabetes, hypertension and dyslipidemia : the AusDiab Study

    NARCIS (Netherlands)

    Snijder, M.B.; Zimmet, P.Z.; Visser, M.; Dekker, J.M.; Seidell, J.C.; Shaw, J.E.

    2004-01-01

    OBJECTIVE: Fat distribution as measured by waist-to-hip ratio has been shown to be an important independent predictor of glucose intolerance. Few studies, however, have considered the contributions of the waist and hip circumferences independently. The aim of this study was to investigate the

  14. Reliability of knee joint range of motion and circumference measurements after total knee arthroplasty: does tester experience matter?

    DEFF Research Database (Denmark)

    Jakobsen, Thomas Linding; Christensen, Malene; Christensen, Stine Sommer

    2010-01-01

    : The design was an intra-tester, inter-tester and intra-day reliability study. Nineteen outpatients (10 females) having received a TKA were examined by an inexperienced and an experienced physiotherapist. Following a standardized protocol, active and passive knee joint ROM and circumference measurements were...

  15. Data acquisition techniques using PC

    CERN Document Server

    Austerlitz, Howard

    1991-01-01

    Data Acquisition Techniques Using Personal Computers contains all the information required by a technical professional (engineer, scientist, technician) to implement a PC-based acquisition system. Including both basic tutorial information as well as some advanced topics, this work is suitable as a reference book for engineers or as a supplemental text for engineering students. It gives the reader enough understanding of the topics to implement a data acquisition system based on commercial products. A reader can alternatively learn how to custom build hardware or write his or her own software.

  16. Constraining lowermost mantle structure with PcP/P amplitude ratios from large aperture arrays

    Science.gov (United States)

    Ventosa, S.; Romanowicz, B. A.

    2015-12-01

    Observations of weak short-period teleseismic body waves help to resolve lowermost mantle structure at short wavelengths, which is essential for understanding mantle dynamics and the interactions between the mantle and core. Their limited amount and uneven distribution are however major obstacles to solve for volumetric structure of the D" region, topography of the core-mantle boundary (CMB) and D" discontinuity, and the trade-offs among them. While PcP-P differential travel times provide important information, there are trade-offs between velocity structure and core-mantle boundary topography, which PcP/P amplitude ratios can help resolve, as long as lateral variations in attenuation and biases due to focusing are small or can be corrected for. Dense broadband seismic networks help to improve signal-to-noise ratio (SNR) of the target phases and signal-to-interference ratio (SIR) of other mantle phases when the slowness difference is large enough. To improve SIR and SNR of teleseismic PcP data, we have introduced the slant-stacklet transform to define coherent-guided filters able to separate and enhance signals according to their slowness, time of arrival and frequency content. We thus obtain optimal PcP/P amplitude ratios in the least-square sense using two short sliding windows to match the P signal with a candidate PcP signal. This method allows us to dramatically increase the amount of high-quality observations of short-period PcP/P amplitude ratios by allowing for smaller events and wider epicentral distance and depth ranges.We present the results of measurement of PcP/P amplitude ratios, sampling regions around the Pacific using dense arrays in North America and Japan. We observe that short-period P waves traveling through slabs are strongly affected by focusing, in agreement with the bias we have observed and corrected for due to mantle heterogeneities on PcP-P travel time differences. In Central America, this bias is by far the stronger anomaly we observe

  17. Cytoprotective effects of fisetin against hypoxia-induced cell death in PC12 cells.

    Science.gov (United States)

    Chen, Pei-Yi; Ho, Yi-Ru; Wu, Ming-Jiuan; Huang, Shun-Ping; Chen, Po-Kong; Tai, Mi-Hsueh; Ho, Chi-Tang; Yen, Jui-Hung

    2015-01-01

    Fisetin (3,7,3',4'-tetrahydroxyflavone), a flavonol compound of flavonoids, exhibits a broad spectrum of biological activities including anti-oxidant, anti-inflammatory, anti-cancer and neuroprotective effects. The aim of this study is to investigate the cytoprotective effect of fisetin and the underlying molecular mechanism against hypoxia-induced cell death in PC12 cells. The results of this study showed that fisetin significantly restored the cell viability of PC12 cells under both cobalt chloride (CoCl₂)- and low oxygen-induced hypoxic conditions. Treatment with fisetin successfully reduced the CoCl₂-mediated reactive oxygen species (ROS) production, which was accompanied by an increase in the cell viability of PC12 cells. Furthermore, we found that treatment of PC12 cells with fisetin markedly upregulated hypoxia-inducible factor 1α (HIF-1α), its nuclear accumulation and the hypoxia-response element (HRE)-driven transcriptional activation. The fisetin-mediated cytoprotection during CoCl₂ exposure was significantly attenuated through the administration of HIF-1α siRNA. Moreover, we demonstrated that MAPK/ERK kinase 1/2 (MEK1/2), p38 MAPK and phosphatidylinositol 3-kinase (PI3 K) inhibitors significantly blocked the increase in cell survival that was induced by fisetin treatment under hypoxic conditions. Consistently, increased phosphorylation of ERK, p38 and Akt proteins was observed in PC12 cells treated with fisetin. However, the fisetin-induced HRE-driven transcription was not affected by inhibition of these kinase signaling pathways. Current results reveal for the first time that fisetin promotes cell survival and protects against hypoxia-induced cell death through ROS scavenging and the activation of HIF1α-, MAPK/ERK-, p38 MAPK- and PI3 K/Akt-dependent signaling pathways in PC12 cells.

  18. Estimating the relative contributions of maternal genetic, paternal genetic and intrauterine factors to offspring birth weight and head circumference.

    Science.gov (United States)

    Rice, Frances; Thapar, Anita

    2010-07-01

    Genetic factors and the prenatal environment contribute to birth weight. However, very few types of study design can disentangle their relative contribution. To examine maternal genetic and intrauterine contributions to offspring birth weight and head circumference. To compare the contribution of maternal and paternal genetic effects. Mothers and fathers were either genetically related or unrelated to their offspring who had been conceived by in vitro fertilization. 423 singleton full term offspring, of whom 262 were conceived via homologous IVF (both parents related), 66 via sperm donation (mother only related) and 95 via egg donation (father only related). Maternal weight at antenatal booking, current weight and maternal height. Paternal current weight and height were all predictors. Infant birth weight and head circumference were outcomes. Genetic relatedness was the main contributing factor between measures of parental weight and offspring birth weight as correlations were only significant when the parent was related to the child. However, there was a contribution of the intrauterine environment to the association between maternal height and both infant birth weight and infant head circumference as these were significant even when mothers were unrelated to their child. Both maternal and paternal genes made contributions to infant birth weight. Maternal height appeared to index a contribution of the intrauterine environment to infant growth and gestational age. Results suggested a possible biological interaction between the intrauterine environment and maternal inherited characteristics which suppresses the influence of paternal genes. 2010 Elsevier Ltd. All rights reserved.

  19. PC index as a proxy of the solar wind energy that entered into the magnetosphere: Development of magnetic substorms

    Science.gov (United States)

    Troshichev, O. A.; Podorozhkina, N. A.; Sormakov, D. A.; Janzhura, A. S.

    2014-08-01

    The Polar Cap (PC) index has been approved by the International Association of Geomagnetism and Aeronomy (IAGA XXII Assembly, Merida, Mexico, 2013) as a new index of magnetic activity. The PC index can be considered to be a proxy of the solar wind energy that enters the magnetosphere. This distinguishes PC from AL and Dst indices that are more related to the dissipation of energy through auroral currents or storage of energy in the ring current during magnetic substorms or storms. The association of the PC index with the direct coupling of the solar wind energy into the magnetosphere is based upon analysis of the relationship of PC with parameters in the solar wind, on the one hand, and correlation between the time series of PC and the AL index (substorm development), on the other hand. This paper (the first of a series) provides the results of statistical investigations that demonstrate a strong correlation between the behavior of PC and the development of magnetic substorms. Substorms are classified as isolated and expanded. We found that (1) substorms are preceded by growth in the RS index, (2) sudden substorm expansion onsets are related to "leap" or "reverse" signatures in the PC index which are indicative of a sharp increase in the PC growth rate, (3) substorms start to develop when PC exceeds a threshold level 1.5 ± 0.5 mV/m irrespective of the length of the substorm growth phase, and (4) there is a linear relation between the intensity of substorms and PC for all substorm events.

  20. Theoretical modeling of the electronic structure and exchange interactions in Cu(II)Pc

    Science.gov (United States)

    Wu, Wei; Fisher, A. J.; Harrison, N. M.; Wang, Hai; Wu, Zhenlin; Gardener, Jules; Heutz, Sandrine; Jones, Tim; Aeppli, Gabriel

    2012-12-01

    We calculate the electronic structure and exchange interactions in a copper(II)phthalocyanine (Cu(II)Pc) crystal as a one-dimensional molecular chain using hybrid exchange density functional theory (DFT). In addition, the intermolecular exchange interactions are also calculated in a molecular dimer using Green's function perturbation theory (GFPT) to illustrate the underlying physics. We find that the exchange interactions depend strongly on the stacking angle, but weakly on the sliding angle (defined in the text). The hybrid DFT calculations also provide an insight into the electronic structure of the Cu(II)Pc molecular chain and demonstrate that on-site electron correlations have a significant effect on the nature of the ground state, the band gap and magnetic excitations. The exchange interactions predicted by our DFT calculations and GFPT calculations agree qualitatively with the recent experimental results on newly found η-Cu(II)Pc and the previous results for the α- and β-phases. This work provides a reliable theoretical basis for the further application of Cu(II)Pc to molecular spintronics and organic-based quantum information processing.