WorldWideScience

Sample records for periodic quality control

  1. Periodic quality control of a linear accelerator using electronic portal imaging

    International Nuclear Information System (INIS)

    Planes Meseguer, D.; Dorado Rodriguez, M. P.; Esposito, R. D.

    2011-01-01

    In this paper we present our solution for the realization of the monthly periodic quality control (CP) geometry - mechanical and multi leaf collimator (MLC), using the electronic system for portal imaging (EPI). We have developed specific programs created with free software. The monitoring results are automatically stored on our web server, along with other information generated in our service.

  2. Quality control in radiotherapy

    International Nuclear Information System (INIS)

    Batalla, A.

    2009-01-01

    The authors discuss the modalities and periodicities of internal quality control on radiotherapy installations. They indicate the different concerned systems and the aspects and items to be controlled (patient and personnel security, apparatus mechanical characteristics, beam quality, image quality, isodose and irradiation duration calculation, data transfer). They present the measurement instruments and tools used for the mechanical controls, dose measurement, beam homogeneity and symmetry, anatomic data acquisition systems, and dose distribution and control imagery calculation

  3. On quality control procedures for solar radiation and meteorological measures, from subhourly to montly average time periods

    Science.gov (United States)

    Espinar, B.; Blanc, P.; Wald, L.; Hoyer-Klick, C.; Schroedter-Homscheidt, M.; Wanderer, T.

    2012-04-01

    Meteorological data measured by ground stations are often a key element in the development and validation of methods exploiting satellite images. These data are considered as a reference against which satellite-derived estimates are compared. Long-term radiation and meteorological measurements are available from a large number of measuring stations. However, close examination of the data often reveals a lack of quality, often for extended periods of time. This lack of quality has been the reason, in many cases, of the rejection of large amount of available data. The quality data must be checked before their use in order to guarantee the inputs for the methods used in modelling, monitoring, forecast, etc. To control their quality, data should be submitted to several conditions or tests. After this checking, data that are not flagged by any of the test is released as a plausible data. In this work, it has been performed a bibliographical research of quality control tests for the common meteorological variables (ambient temperature, relative humidity and wind speed) and for the usual solar radiometrical variables (horizontal global and diffuse components of the solar radiation and the beam normal component). The different tests have been grouped according to the variable and the average time period (sub-hourly, hourly, daily and monthly averages). The quality test may be classified as follows: • Range checks: test that verify values are within a specific range. There are two types of range checks, those based on extrema and those based on rare observations. • Step check: test aimed at detecting unrealistic jumps or stagnation in the time series. • Consistency checks: test that verify the relationship between two or more time series. The gathered quality tests are applicable for all latitudes as they have not been optimized regionally nor seasonably with the aim of being generic. They have been applied to ground measurements in several geographic locations, what

  4. [Effect of antecedent dry period on water quality of urban storm runoff pollution].

    Science.gov (United States)

    Bian, Bo

    2009-12-01

    Identified the main factor influencing urban rainfall-runoff pollution provides a scientific basis for urban rainfall-runoff pollution control and management. Therefore, starting in May 2006, a study was conducted to characterize water quality from representative land uses types in Zhenjiang to analyse the effect of antecedent dry period on stormwater runoff quality. The results show that the beginning of rainfall, with the increase of antecedent dry periods, the percentages of less than 40 microm is increased, the correlation of the water quality parameters (TN, TP, Zn, Pb, Cu, TSS and COD) and antecedent dry period shows a significant positive correlation, dissolved pollutants in the initial period surface runoff is increased. These findings show that facilitating the recognition of antecedent dry periods is the main factor influencing the change in concentration and partitioning of pollutants to provide the scientific basis for non-point source pollution control and management.

  5. Quality control of the activity meter

    International Nuclear Information System (INIS)

    Rodrigues, Marlon da Silva Brandão; Sá, Lídia Vasconcelos de

    2017-01-01

    Objective: To carry out a comparative analysis of national and international standards regarding the quality control of the activity meter used in Nuclear Medicine Services in Brazil. Material and methods: Quality control protocols from the International Atomic Energy Agency (IAEA), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC) were pointed out and compared with requirements from both regulatory Brazilian agencies, National Surveillance Agency (ANVISA) and National Nuclear Energy Commission (CNEN). Results: The daily routine tests recommended by the regulatory agencies do not have significant differences; in contrast the tests with higher periodicities like (accuracy, linearity and precision) have differences discrepant. Conclusion: In view of the comparative analysis carried out, it is suggested that the national recommendations for the quality control tests of the activity meter should be checked and evaluated, with emphasis on the semiannual and annual periodicity tests. (author)

  6. Quality control guarantees the safety of radiotherapy

    International Nuclear Information System (INIS)

    Aaltonen, P.

    1994-01-01

    While radiotherapy equipment has seen some decisive improvements in the last few decades, the technology has also become more complicated. The advanced equipment produces increasingly good treatment results, but the condition of the equipment must be controlled efficiently so as to eliminate any defects that might jeopardise patient safety. The quality assurance measures that are taken to show that certain equipment functions as required are known as quality control. The advanced equipment and stricter requirements set for the precision of radiotherapy have meant that more attention must be paid to quality control. The present radiation legislation stipulates that radiotherapy equipment must undergo regular quality control. The implementation of the quality control is supervised by the Finnish Centre for Radiation and Nuclear Safety (STUK). Hospitals carry out quality control in accordance with a programme approved by STUK, and STUK inspectors periodically visit hospitals to check the results of quality control. (orig.)

  7. Quality control of a virtual simulation installation. SFPM report nr 25, August 2009

    International Nuclear Information System (INIS)

    Foulquier, Jean-Noel; Allieres, Norbert; Batalla, Alain; Beaumont, Stephane; Di Bartolo, Cristelle; Khodri, Mustapha; Tauziede, Jean-Marc; Dedieu, Veronique; Bramoule, Celine; Caselles, Olivier; Lacaze, Brigitte; Mazurier, Jocelyne

    2009-08-01

    This report is a notably comprehensive guide for the different controls which can be performed on devices present in a Virtual Simulation installation. After a brief historical recall, the authors present the definition and organisation of a virtual simulation, the different components of a virtual simulation installation, and the different steps of virtual simulation process. Then, they address the quality control of the scanner-simulator (linearity and periodicity of controls, patient table or support, tolerance levels and periodicity of controls of this support). They address tracking systems (quality control of laser systems), the quality control of virtual simulation tools (iso-centre contouring and positioning, ballistic tools, tolerance levels, control periodicity), the quality control of data transfer or objects (elements to be analysed during an image transfer, tolerance levels and control periodicity), the imager quality control, and tests phantoms (the physical and digital phantoms)

  8. 40 CFR 97.272 - Out of control periods.

    Science.gov (United States)

    2010-07-01

    ... Out of control periods. (a) Whenever any monitoring system fails to meet the quality-assurance and.... (b) Audit decertification. Whenever both an audit of a monitoring system and a review of the initial... certification or recertification application submission and at the time of the audit, the Administrator will...

  9. 40 CFR 97.372 - Out of control periods.

    Science.gov (United States)

    2010-07-01

    ... Out of control periods. (a) Whenever any monitoring system fails to meet the quality-assurance and... appendix E to, part 75 of this chapter. (b) Audit decertification. Whenever both an audit of a monitoring... the time of the audit, the Administrator will issue a notice of disapproval of the certification...

  10. 40 CFR 97.172 - Out of control periods.

    Science.gov (United States)

    2010-07-01

    ... Out of control periods. (a) Whenever any monitoring system fails to meet the quality-assurance and... appendix E to, part 75 of this chapter. (b) Audit decertification. Whenever both an audit of a monitoring... the time of the audit, the Administrator will issue a notice of disapproval of the certification...

  11. Periodic quality control of a linear accelerator using electronic portal imaging; Controles de calidad periodicos de un acelerador lineal utilizando el sistema electronico de imagenes portales

    Energy Technology Data Exchange (ETDEWEB)

    Planes Meseguer, D.; Dorado Rodriguez, M. P.; Esposito, R. D.

    2011-07-01

    In this paper we present our solution for the realization of the monthly periodic quality control (CP) geometry - mechanical and multi leaf collimator (MLC), using the electronic system for portal imaging (EPI). We have developed specific programs created with free software. The monitoring results are automatically stored on our web server, along with other information generated in our service.

  12. Experiences in the application of quality control and quality assurance programmes in water reactor fuel fabrication

    International Nuclear Information System (INIS)

    Balaramamoorthy, K.; Vijayaraghavan, R.; Kulkarni, P.G.; Raghavan, S.V.; Bandyopadhyay, A.K.

    1984-01-01

    Nuclear fuel for Research Reactors and Pressurised Heavy Water Reactors (PHWRs) is being fabricated in India for a period of over two decades. The fuel is produced to conform to stringent quality control specifications. Generally, the performance of the fuel has been very good in the reactors. This is not only due to the high quality workmanship in the various stages of production but also to the meticulous care exercised in the planning and application of quality control and quality assurance procedures. For the nuclear fuel used in Water Reactors, extensive material specifications have been compiled and they are periodically reviewed and revised. The specifications cover various aspects such as metallurgical and mechanical properties, non-destructive testing, dimensional and visual standard requirements. Similarly, detailed manufacturing engineering instructions (MEIs) and quality control instructions (QCIs) have been drawn. For any deviations from the specified requirements, design concession committee considers all deviations and acceptance or rejection criteria are evolved. In this task, the design concession committee is supported by experimentation in various laboratories of the Department of Atomic Energy. The Quality Assurance procedures have been evolved over a long period of time. They generally conform to the latest code and recommended guides of IAEA regarding Quality Assurance in the manufacture of fuel. (orig.)

  13. Quality control of the activity meter; Controle de qualidade do ativímetro

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Marlon da Silva Brandão; Sá, Lídia Vasconcelos de, E-mail: nolramsbr@gmail.com [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Objective: To carry out a comparative analysis of national and international standards regarding the quality control of the activity meter used in Nuclear Medicine Services in Brazil. Material and methods: Quality control protocols from the International Atomic Energy Agency (IAEA), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC) were pointed out and compared with requirements from both regulatory Brazilian agencies, National Surveillance Agency (ANVISA) and National Nuclear Energy Commission (CNEN). Results: The daily routine tests recommended by the regulatory agencies do not have significant differences; in contrast the tests with higher periodicities like (accuracy, linearity and precision) have differences discrepant. Conclusion: In view of the comparative analysis carried out, it is suggested that the national recommendations for the quality control tests of the activity meter should be checked and evaluated, with emphasis on the semiannual and annual periodicity tests. (author)

  14. Quality control activities in the environmental radiology laboratory

    International Nuclear Information System (INIS)

    Llaurado, M.; Quesada, D.; Rauret, G.; Tent, J.; Zapata, D.

    2006-01-01

    During the last twenty years many analytical laboratories have implemented quality assurance systems. A quality system implementation requires documentation of all activities (technical and management), evaluation of these activities and its continual improvement. Implementation and adequate management of all the elements a quality system includes are not enough to guarantee quality of the analytical results generated at a time. That is the aim of a group of specific activities labelled as quality control activities. The Laboratori de Radiologia Ambiental (Environmental Radiology Laboratory; LRA) at the University of Barcelona was created in 1984 to carry out part of the quality control assays of the Environmental Radiology Monitoring Programs around some of the Spanish nuclear power plants, which are developed by the Servei Catala d'Activitats Energetiques (SCAR) and the Consejo de Seguridad Nuclear (CSN), organisations responsible for nuclear security and radiological protection. In these kind of laboratories, given the importance of the results they give, quality control activities become an essential aspect. In order to guarantee the quality of its analytical results, the LRA Direction decided to adopt the international standard UNE-EN ISO/IEC 17025 for its internal quality system and to accreditate some of the assays it carries out. In such as system, it is established, the laboratory shall monitor the validity of tests undertaken and data shall be recorded in such a way that trends are detectable. The present work shows the activities carried out in this way by the LRA, which are: Equipment control activities which in the special case of radiochemical techniques include measurement of backgrounds and blanks as well as periodical control of efficiency and resolution. Activities to assure the specifications settled by method validation, which are testing of reference materials and periodical analysis of control samples. Evaluation of the laboratory work quality

  15. Internal quality control indicators of cervical cytopathology exams performed in laboratories monitored by the External Quality Control Laboratory.

    Science.gov (United States)

    Ázara, Cinara Zago Silveira; Manrique, Edna Joana Cláudio; Tavares, Suelene Brito do Nascimento; de Souza, Nadja Lindany Alves; Amaral, Rita Goreti

    2014-09-01

    To evaluate the impact of continued education provided by an external quality control laboratory on the indicators of internal quality control of cytopathology exams. The internal quality assurance indicators for cytopathology exams from 12 laboratories monitored by the External Quality Control Laboratory were evaluated. Overall, 185,194 exams were included, 98,133 of which referred to the period preceding implementation of a continued education program, while 87,061 referred to the period following this intervention. Data were obtained from the Cervical Cancer Database of the Brazilian National Health Service. Following implementation of the continued education program, the positivity index (PI) remained within recommended limits in four laboratories. In another four laboratories, the PI progressed from below the limits to within the recommended standards. In one laboratory, the PI remained low, in two laboratories, it remained very low, and in one, it increased from very low to low. The percentage of exams compatible with a high-grade squamous intraepithelial lesion (HSIL) remained within the recommended limits in five laboratories, while in three laboratories it progressed from below the recommended levels to >0.4% of the total number of satisfactory exams, and in four laboratories it remained below the standard limit. Both the percentage of atypical squamous cells of undetermined significance (ASC-US) in relation to abnormal exams, and the ratio between ASC-US and intraepithelial lesions remained within recommended levels in all the laboratories investigated. An improvement was found in the indicators represented by the positivity index and the percentage of exams compatible with a high-grade squamous intraepithelial lesion, showing that the role played by the external quality control laboratory in providing continued education contributed towards improving laboratory staff skills in detecting cervical cancer precursor lesions.

  16. Quality control for exposure assessment in epidemiological studies

    DEFF Research Database (Denmark)

    Bornkessel, C; Blettner, M; Breckenkamp, J

    2010-01-01

    In the framework of an epidemiological study, dosemeters were used for the assessment of radio frequency electromagnetic field exposure. To check the correct dosemeter's performance in terms of consistency of recorded field values over the entire study period, a quality control strategy...... was developed. In this paper, the concept of quality control and its results is described. From the 20 dosemeters used, 19 were very stable and reproducible, with deviations of a maximum of +/-1 dB compared with their initial state. One device was found to be faulty and its measurement data had to be excluded...... from the analysis. As a result of continuous quality control procedures, the confidence in the measurements obtained during the field work was strengthened significantly....

  17. In-house quality audit and benefits of some quality control procedures in the quality assurance of TL dosimetry system at NRPB

    International Nuclear Information System (INIS)

    Dutt, J.C.

    1993-01-01

    A number of Quality Control (QC) procedures have been introduced into the running and operation of the NRPB personal monitoring services. Those described here apply to the whole-body TL dosimetry system. These QC procedures comprise Quality Assurance (QA) of incoming raw materials and equipment, reader stabilisation, daily, routine and periodic QA checks on all phases of the service. In-house quality audit, periodic internal and external 'blind QA checks' on the dosimetry system as a whole have assured the continuing high quality and reliability of the NRPB TL dosimetry service for assessing body and skin doses of radiation workers from external photon and beta radiations. (author)

  18. Association between product quality control and process quality control of bulk milk

    NARCIS (Netherlands)

    Velthuis, A.; Asseldonk, van M.A.P.M.

    2010-01-01

    Assessment of dairy-milk quality is based on product quality control (testing bulk-milk samples) and process quality control (auditing dairy farms). It is unknown whether process control improves product quality. To quantify possible association between product control and process control a

  19. Quality Control Applications

    CERN Document Server

    Chorafas, Dimitris N

    2013-01-01

    Quality control is a constant priority in electrical, mechanical, aeronautical, and nuclear engineering – as well as in the vast domain of electronics, from home appliances to computers and telecommunications. Quality Control Applications provides guidance and valuable insight into quality control policies; their methods, their implementation, constant observation and associated technical audits. What has previously been a mostly mathematical topic is translated here for engineers concerned with the practical implementation of quality control. Once the fundamentals of quality control are established, Quality Control Applications goes on to develop this knowledge and explain how to apply it in the most effective way. Techniques are described and supported using relevant, real-life, case studies to provide detail and clarity for those without a mathematical background. Among the many practical examples, two case studies dramatize the importance of quality assurance: A shot-by-shot analysis of the errors made ...

  20. Studies of quality control procedures for radiopharmaceuticals

    International Nuclear Information System (INIS)

    Zivanovic, M.; Trott, N.G.

    1983-01-01

    In this paper, a short description is given of a radiopharmaceutical preparation suite set up at the Royal Marsden Hospital and an account is presented of methods used for quality control of radiopharmaceuticals and of the results obtained over a period of about two and a half years

  1. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    OpenAIRE

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  2. From quality control to quality systems in x-ray radiology. Step by step approach

    International Nuclear Information System (INIS)

    Gendrutis Morkunas; Julius Ziliukas

    2007-01-01

    Complete test of publication follows. Quality systems in x-ray radiology as in any area of medical exposure is an important tool of optimization of radiation protection. Creation of these systems is related with a number of problems: limited resources, lack of knowledge and experience, negative attitude of hospitals staff and administration, lack of advice from outside. Problems related with transitionary period might be softened by the step by step approach. The following steps might be indicated: providing information on quality systems to hospital staff and administration, simple quality control procedures done by outside experts in hospitals, preparation of quality related procedures by hospital staff, practical implementation of quality control procedures done by hospital staff, preparation of quality manual by hospital staff, its integration into common quality system of hospital (if it is available) and constant development, measurements of performance indicators (e.g., patients' doses) and introduction of corrective measures if necessary, dissemination of experience by expert organizations and more advanced hospitals. These steps are to be discussed in the presentations based on Lithuanian experience since 1998.

  3. Implementing self sustained quality control procedures in a clinical laboratory.

    Science.gov (United States)

    Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N

    2013-01-01

    Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.

  4. Austrian Daily Climate Data Rescue and Quality Control

    Science.gov (United States)

    Jurkovic, A.; Lipa, W.; Adler, S.; Albenberger, J.; Lechner, W.; Swietli, R.; Vossberg, I.; Zehetner, S.

    2010-09-01

    Checked climate datasets are a "conditio sine qua non" for all projects that are relevant for environment and climate. In the framework of climate change studies and analysis it is essential to work with quality controlled and trustful data. Furthermore these datasets are used as input for various simulation models. In regard to investigations of extreme events, like strong precipitation periods, drought periods and similar ones we need climate data in high temporal resolution (at least in daily resolution). Because of the historical background - during Second World War the majority of our climate sheets were sent to Berlin, where the historical sheets were destroyed by a bomb attack and so important information got lost - only several climate sheets, mostly duplicates, before 1939 are available and stored in our climate data archive. In 1970 the Central Institute for Meteorology and Geodynamics in Vienna started a first attempt to digitize climate data by means of punch cards. With the introduction of a routinely climate data quality control in 1984 we can speak of high-class-checked daily data (finally checked data, quality flag 6). Our group is working on the processing of digitization and quality control of the historical data for the period 1872 to 1983 for 18 years. Since 2007 it was possible to intensify the work (processes) in the framework of an internal project, namely Austrian Climate Data Rescue and Quality Control. The aim of this initiative was - and still is - to supply daily data in an outstanding good and uniform quality. So this project is a kind of pre-project for all scientific projects which are working with daily data. In addition to routine quality checks (that are running since 1984) using the commercial Bull Software we are testing our data with additional open source software, namely ProClim.db. By the use of this spatial and statistical test procedure, the elements air temperature and precipitation - for several sites in Carinthia - could

  5. Principles and Practices for Quality Assurance and Quality Control

    Science.gov (United States)

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  6. Features of high-speed and strength qualities development in young biathlonists aged 14–15 in the preparatory period

    Directory of Open Access Journals (Sweden)

    Artem Burla

    2015-04-01

    Full Text Available Purpose: to substantiate a methodology of high-speed and strength qualities development of young biathlonists aged 14–15 during the preparatory period. Material and Methods: young biathlonists aged 14–15 from control and experimental groups took part in the research. There were 12 athletes in each group. Pedagogical methods and methods of mathematical statistics were used in the work. Pedagogical methods of researches were used for level definition of high-speed and strength qualities development of young biathlonists. Results: reliable increase of motive qualities and polydynamometry results testing of young biathlonists from the experimental group due to implementation of the experimental methodology in the preparatory period is established. Conclusions: application of the developed complexes in the preparatory period in the experimental group of young biathlonists aged 14–15 allows to raise indices of motive qualities and polydynamometry testing statistically significantly.

  7. Checking quality control?

    DEFF Research Database (Denmark)

    Brodersen, Lars

    2005-01-01

    How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?......How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?...

  8. Quality control and performance evaluation of microselectron HDR machine over 30 months

    International Nuclear Information System (INIS)

    Balasubramanian, N.; Annex, E.H.; Sunderam, N.; Patel, N.P.; Kaushal, V.

    2008-01-01

    To assess the performance evaluation of Microselectron HDR machine the standard quality control and quality assurance checks were carried out after each loading of new 192 Ir brachytherapy source In the machine. Total 9 loadings were done over a period of 30 months

  9. Microprocessor controlled digital period meter

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1980-01-01

    A microprocessor controlled digital period meter has been developed and tested operationally on a reactor at Argonne National Laboratory. The principle of operation is the mathematical relationship between asymptotic periods and pulse counting circuitry. This relationship is used to calculate and display the reactor periods over a range of /plus or minus/1 second to /plus or minus/999 seconds. The time interval required to update each measurement automatically varies from 8 seconds at the lowest counting rates to 2 seconds at higher counting rates. The paper will describe hardware and software design details and show the advantages of this type of Period Meter over the conventional circuits. 1 ref

  10. Quality control of intelligence research

    International Nuclear Information System (INIS)

    Lu Yan; Xin Pingping; Wu Jian

    2014-01-01

    Quality control of intelligence research is the core issue of intelligence management, is a problem in study of information science This paper focuses on the performance of intelligence to explain the significance of intelligence research quality control. In summing up the results of the study on the basis of the analysis, discusses quality control methods in intelligence research, introduces the experience of foreign intelligence research quality control, proposes some recommendations to improve quality control in intelligence research. (authors)

  11. Interaction between production control and quality control

    NARCIS (Netherlands)

    Bij, van der J.D.; Ekert, van J.H.W.

    1999-01-01

    Describes a qualitative study on interaction between systems for production control and quality control within industrial organisations. Production control and quality control interact in a sense. Good performance for one aspect often influences or frustrates the performance of the other. As far as

  12. Quality Model of Foodstuff in the Control of Refrigerated Display Cabinet

    DEFF Research Database (Denmark)

    Cai, Junping; Risum, Jørgen; Thybo, Claus

    2006-01-01

    Commercial refrigerating systems need to be defrosted regularly to maintain a satisfactory performance. When defrosting the evaporator coil, the air temperature inside the display cabinet will increase, and float outside the normal temperature range for a period of time, the question is what...... happens to the food inside during this period, when we look at the quality factor? This paper discusses quality model of foodstuff, different scenarios of defrost scheme are simulated, questions such as how the defrost temperature and duration influence the food temperature, thus the food quality, as well...... as what is the optimal defrost scheme from food quality point of view are answered. This will serve as a prerequisite of designing of optimal control scheme for the commercial refrigeration system, aiming at optimizing a weighed cost function of both food quality and overall energy consumption of system....

  13. Multi-periodic nanostructures for photon control

    DEFF Research Database (Denmark)

    Kluge, Christian; Adam, Jost; Barié, Nicole

    2014-01-01

    We propose multi-periodic nanostructures yielded by superposition of multiple binary gratings for wide control over photon emission in thin-film devices. We present wavelength- and angle-resolved photoluminescence measurements of multi-periodically nanostructured organic light-emitting layers...

  14. Development and implementation of an automated quantitative film digitizer quality control program

    Science.gov (United States)

    Fetterly, Kenneth A.; Avula, Ramesh T. V.; Hangiandreou, Nicholas J.

    1999-05-01

    A semi-automated, quantitative film digitizer quality control program that is based on the computer analysis of the image data from a single digitized test film was developed. This program includes measurements of the geometric accuracy, optical density performance, signal to noise ratio, and presampled modulation transfer function. The variability of the measurements was less than plus or minus 5%. Measurements were made on a group of two clinical and two laboratory laser film digitizers during a trial period of approximately four months. Quality control limits were established based on clinical necessity, vendor specifications and digitizer performance. During the trial period, one of the digitizers failed the performance requirements and was corrected by calibration.

  15. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The practice of nuclear diagnostic imaging requires an appropriate quality assurance program to attain high standards of efficiency and reliability. The International Atomic Energy Agency defines the term quality assurance as ''the closeness with which the outcome of a given procedure approaches some ideal, free from all errors and artifacts.'' The term quality control is used in reference to the specific measures taken to ensure that one particular aspect of the procedure is satisfactory. Therefore, quality assurance is a hospital-wide concept that should involve all aspects of clinical practice. Quality control is concerned with the submission of requests for procedures; the scheduling of patients; the preparation and dispensing of radiopharmaceuticals; the protection of patients, staff, and the general public against radiation hazards and accidents caused by radioactive materials or by faulty equipment; the setting up, use, and maintenance of electronic instruments; the methodology of the actual procedures; the analysis and interpretation of data; the reporting of results; and, finally, the keeping of records. The chapter discusses each of these areas

  16. Implementation of basic quality control tests for malaria medicines in Amazon Basin countries: results for the 2005-2010 period.

    Science.gov (United States)

    Pribluda, Victor S; Barojas, Adrian; Añez, Arletta; López, Cecilia G; Figueroa, Ruth; Herrera, Roxana; Nakao, Gladys; Nogueira, Fernando Ha; Pianetti, Gerson A; Povoa, Marinete M; Viana, Giselle Mr; Gomes, Margarete S Mendonça; Escobar, Jose P; Sierra, Olga L Muñoz; Norena, Susana P Rendon; Veloz, Raúl; Bravo, Marcy Silva; Aldás, Martha R; Hindssemple, Alison; Collins, Marilyn; Ceron, Nicolas; Krishnalall, Karanchand; Adhin, Malti; Bretas, Gustavo; Hernandez, Nelly; Mendoza, Marjorie; Smine, Abdelkrim; Chibwe, Kennedy; Lukulay, Patrick; Evans, Lawrence

    2012-06-15

    Ensuring the quality of malaria medicines is crucial in working toward malaria control and eventual elimination. Unlike other validated tests that can assess all critical quality attributes, which is the standard for determining the quality of medicines, basic tests are significantly less expensive, faster, and require less skilled labour; yet, these tests provide reproducible data and information on several critical quality attributes, such as identity, purity, content, and disintegration. Visual and physical inspection also provides valuable information about the manufacturing and the labelling of medicines, and in many cases this inspection is sufficient to detect counterfeit medicines. The Promoting the Quality of Medicines (PQM) programme has provided technical assistance to Amazon Malaria Initiative (AMI) countries to implement the use of basic tests as a key screening mechanism to assess the quality of malaria medicines available to patients in decentralized regions. Trained personnel from the National Malaria Control Programmes (NMCPs), often in collaboration with country's Official Medicine Control Laboratory (OMCL), developed country- specific protocols that encompassed sampling methods, sample analysis, and data reporting. Sampling sites were selected based on malaria burden, accessibility, and geographical location. Convenience sampling was performed and countries were recommended to store the sampled medicines under conditions that did not compromise their quality. Basic analytical tests, such as disintegration and thin layer chromatography (TLC), were performed utilizing a portable mini-laboratory. Results were originally presented at regional meetings in a non-standardized format that lacked relevant medicines information. However, since 2008 information has been submitted utilizing a template specifically developed by PQM for that purpose. From 2005 to 2010, the quality of 1,663 malaria medicines from seven AMI countries was evaluated, mostly

  17. [On-site quality control of acupuncture randomized controlled trial: design of content and checklist of quality control based on PICOST].

    Science.gov (United States)

    Li, Hong-Jiao; He, Li-Yun; Liu, Zhi-Shun; Sun, Ya-Nan; Yan, Shi-Yan; Liu, Jia; Zhao, Ye; Liu, Bao-Yan

    2014-02-01

    To effectively guarantee quality of randomized controlld trial (RCT) of acupuncture and develop reasonable content and checklist of on-site quality control, influencing factors on quality of acupuncture RCT are analyzed and scientificity of quality control content and feasibility of on-site manipulation are put into overall consideration. Based on content and checklist of on-site quality control in National 11th Five-Year Plan Project Optimization of Comprehensive Treatment Plan for TCM in Prevention and Treatment of Serious Disease and Clinical Assessment on Generic Technology and Quality Control Research, it is proposed that on-site quality control of acupuncture RCT should be conducted with PICOST (patient, intervention, comparison, out come, site and time) as core, especially on quality control of interveners' skills and outcome assessment of blinding, and checklist of on-site quality control is developed to provide references for undertaking groups of the project.

  18. Quality control in public participation assessments of water quality: the OPAL Water Survey.

    Science.gov (United States)

    Rose, N L; Turner, S D; Goldsmith, B; Gosling, L; Davidson, T A

    2016-07-22

    Public participation in scientific data collection is a rapidly expanding field. In water quality surveys, the involvement of the public, usually as trained volunteers, generally includes the identification of aquatic invertebrates to a broad taxonomic level. However, quality assurance is often not addressed and remains a key concern for the acceptance of publicly-generated water quality data. The Open Air Laboratories (OPAL) Water Survey, launched in May 2010, aimed to encourage interest and participation in water science by developing a 'low-barrier-to-entry' water quality survey. During 2010, over 3000 participant-selected lakes and ponds were surveyed making this the largest public participation lake and pond survey undertaken to date in the UK. But the OPAL approach of using untrained volunteers and largely anonymous data submission exacerbates quality control concerns. A number of approaches were used in order to address data quality issues including: sensitivity analysis to determine differences due to operator, sampling effort and duration; direct comparisons of identification between participants and experienced scientists; the use of a self-assessment identification quiz; the use of multiple participant surveys to assess data variability at single sites over short periods of time; comparison of survey techniques with other measurement variables and with other metrics generally considered more accurate. These quality control approaches were then used to screen the OPAL Water Survey data to generate a more robust dataset. The OPAL Water Survey results provide a regional and national assessment of water quality as well as a first national picture of water clarity (as suspended solids concentrations). Less than 10 % of lakes and ponds surveyed were 'poor' quality while 26.8 % were in the highest water quality band. It is likely that there will always be a question mark over untrained volunteer generated data simply because quality assurance is uncertain

  19. Chicken meat quality as a function of fasting period and water spray

    Directory of Open Access Journals (Sweden)

    CM Komiyama

    2008-09-01

    Full Text Available This study aimed at evaluating the effect of different fasting periods and water spray during lairage on the quality of chicken meat. A number of 300 male Ross broilers were reared up to 42 days of age, and submitted to four pre-slaughter fasting periods (4, 8, 12, and 16 hours and sprayed with water or not during lairage. Deboned breast meat was submitted to the following analysis: pH, color, drip loss, water retention capacity, cooking loss, and shear force. There was a significant effect (p < 0.05 of fasting period on meat luminosity was significantly different, with the highest value obtained for 4-hour fasting, whereas no difference was found among the other fasting periods. Meat pH values were different among fasting periods when birds received water spray, with birds fasted for 4, 8, and 12 hours of fasting presenting lower meat pH values (5.87, 5.87, and 6.04, respectively. The interaction between fasting period and water spray influenced meat drip loss and cooking loss, with birds fasted for 16h and not receiving water spray presenting higher drip loss (4.88 and higher cooking loss (28.24 as compared to the other birds. Fasting period affects meat quality, and very short periods (4h impair meat quality.

  20. Software product quality control

    CERN Document Server

    Wagner, Stefan

    2013-01-01

    Quality is not a fixed or universal property of software; it depends on the context and goals of its stakeholders. Hence, when you want to develop a high-quality software system, the first step must be a clear and precise specification of quality. Yet even if you get it right and complete, you can be sure that it will become invalid over time. So the only solution is continuous quality control: the steady and explicit evaluation of a product's properties with respect to its updated quality goals.This book guides you in setting up and running continuous quality control in your environment. Star

  1. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1986-01-01

    General preconditions and methods for QA work in the nuclear field are analysed. The application of general QA principles to actual situations is illustrated by examples in the fields of engineering and of the manufacturing of mechanical and electrical components. All QA measures must be fitted to the complexity and relevance of the work steps, which are under consideration. The key to good product quality is the control of working processes. The term 'controlled process' is discussed in detail and examples of feed back systems are given. The main QA measures for the operation of nuclear power plants include the establishment of a Quality Assurance Program, training and qualification of personnel, procurement control, inspection and tests, reviews and audits. These activities are discussed. (orig.)

  2. Quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Leme, P.R.

    1983-01-01

    The following topics are discussed: objectives of the quality control in nuclear medicine; the necessity of the quality control in nuclear medicine; guidelines and recommendations. An appendix is given concerning the guidelines for the quality control and instrumentation in nuclear medicine. (M.A.) [pt

  3. Speed Synchronization Control of Integrated Motor–Transmission Powertrain over CAN through Active Period-Scheduling Approach

    Directory of Open Access Journals (Sweden)

    Wanke Cao

    2017-11-01

    Full Text Available This paper deals with the speed synchronization control of integrated motor–transmission (IMT powertrain systems in pure electric vehicles (EVs over a controller area network (CAN subject to both network-induced delays and network congestion. A CAN has advantages over point-to-point communication; however, it imposes network-induced delays and network congestion into the control system, which can deteriorate the shifting quality and make system integration difficult. This paper presents a co-design scheme combining active period scheduling and discrete-time slip mode control (SMC to deal with both network-induced delays and network congestion of the CAN, which improves the speed synchronization control for high shifting quality and prevents network congestion for the system’s integration. The results of simulations and hardware-in-loop experiments show the effectiveness of the proposed scheme, which can ensure satisfactory speed synchronization performance while significantly reducing the network’s utilization.

  4. Chronic Low Quality Sleep Impairs Postural Control in Healthy Adults.

    Science.gov (United States)

    Furtado, Fabianne; Gonçalves, Bruno da Silva B; Abranches, Isabela Lopes Laguardia; Abrantes, Ana Flávia; Forner-Cordero, Arturo

    2016-01-01

    The lack of sleep, both in quality and quantity, is an increasing problem in modern society, often related to workload and stress. A number of studies have addressed the effects of acute (total) sleep deprivation on postural control. However, up to date, the effects of chronic sleep deficits, either in quantity or quality, have not been analyzed. Thirty healthy adults participated in the study that consisted of registering activity with a wrist actigraph for more than a week before performing a series of postural control tests. Sleep and circadian rhythm variables were correlated and the sum of activity of the least active 5-h period, L5, a rhythm variable, obtained the greater coefficient value with sleep quality variables (wake after sleep onset WASO and efficiency sleep). Cluster analysis was performed to classify subjects into two groups based on L5 (low and high). The balance tests scores used to asses postural control were measured using Biodex Balance System and were compared between the two groups with different sleep quality. The postural tests were divided into dynamic (platform tilt with eyes open, closed and cursor) and static (clinical test of sensory integration). The results showed that during the tests with eyes closed, the group with worse sleep quality had also worse postural control performance. Lack of vision impairs postural balance more deeply in subjects with chronic sleep inefficiency. Chronic poor sleep quality impairs postural control similarly to total sleep deprivation.

  5. Chronic Low Quality Sleep Impairs Postural Control in Healthy Adults.

    Directory of Open Access Journals (Sweden)

    Fabianne Furtado

    Full Text Available The lack of sleep, both in quality and quantity, is an increasing problem in modern society, often related to workload and stress. A number of studies have addressed the effects of acute (total sleep deprivation on postural control. However, up to date, the effects of chronic sleep deficits, either in quantity or quality, have not been analyzed. Thirty healthy adults participated in the study that consisted of registering activity with a wrist actigraph for more than a week before performing a series of postural control tests. Sleep and circadian rhythm variables were correlated and the sum of activity of the least active 5-h period, L5, a rhythm variable, obtained the greater coefficient value with sleep quality variables (wake after sleep onset WASO and efficiency sleep. Cluster analysis was performed to classify subjects into two groups based on L5 (low and high. The balance tests scores used to asses postural control were measured using Biodex Balance System and were compared between the two groups with different sleep quality. The postural tests were divided into dynamic (platform tilt with eyes open, closed and cursor and static (clinical test of sensory integration. The results showed that during the tests with eyes closed, the group with worse sleep quality had also worse postural control performance. Lack of vision impairs postural balance more deeply in subjects with chronic sleep inefficiency. Chronic poor sleep quality impairs postural control similarly to total sleep deprivation.

  6. Analytical quality control in studies of environmental exposure to mercury

    International Nuclear Information System (INIS)

    Byrne, A.R.; Prosenc, N.; Smerke, J.; Horvat, M.

    1995-01-01

    The work of the laboratory for quality control in this co-ordinated project for the period from November 1993 to June 1994 is presented. The major effort was devoted to assisting in establishing the homogeneity and total methylmercury levels in two new hair reference materials prepared as control materials for the project, numbered 085 (spiked) and 086 (natural level). Results for some hair materials from participants are also given. (author)

  7. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Science.gov (United States)

    2010-07-01

    ... quality assurance audit or any other audit, the system is out-of-control. The owner or operator shall... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  8. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Kristensen, K.

    1981-01-01

    Quality assurance was introduced in the pharmaceutical field long before it was used in many other areas, and the term quality control has been used in a much broader sense than merely analytical quality control. The term Good Manufacturing Practice (GMP) has been used to describe the system used for producing safe and effective drugs of a uniform quality. GMP has also been used for the industrial production of radiopharmaceuticals. For the preparation and control of radiopharmaceuticals in hospitals a similar system has been named Good Radiopharmacy Practice (GRP). It contains the same elements as GMP but takes into account the special nature of this group of drugs. Data on the assessment of the quality of radiopharmaceuticals in relation to present standards are reviewed. The general conclusion is that the quality of radiopharmaceuticals appears comparable to that of other drugs. It seems possible to establish the production of radiopharmaceuticals, generators and preparation kits in such a way that analytical control of the final product at the hospital may be limited provided the final preparation work is carried out in accordance with GRP principles. The elements of GRP are reviewed. (author)

  9. Commercial jet fuel quality control

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, K.H.

    1995-05-01

    The paper discusses the purpose of jet fuel quality control between the refinery and the aircraft. It describes fixed equipment, including various types of filters, and the usefulness and limitations of this equipment. Test equipment is reviewed as are various surveillance procedures. These include the Air Transport Association specification ATA 103, the FAA Advisory Circular 150/5230-4, the International Air Transport Association Guidance Material for Fuel Quality Control and Fuelling Service and the Guidelines for Quality Control at Jointly Operated Fuel Systems. Some past and current quality control problems are briefly mentioned.

  10. SPECT quality control tests

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.; Abe, R.

    1987-01-01

    Quality control tests of tomographic system composed by a rotatory chamber (CGR Gammatomome T-9000) and a microcomputer are presented. Traditional quality control tests for scintilation chambers and specific tests for tomographic systems are reported. (M.A.C.) [pt

  11. [Correlation between social support and quality of life in patients with breast cancer at different periods of treatment].

    Science.gov (United States)

    Yang, L; Song, W P; Chen, Z L; Wang, Y; Chen, Y Y; Hua, Y H; Chen, M; Zou, W B

    2017-03-23

    Objective: To analyze the differences between the social support for breast cancer patients and healthy female, and to explore the correlation between social support and quality of life (QOL) in the patients. Methods: From January 2013 to December 2014, 101 patients with operable breast cancer treated at Xinyu City People's Hospital were recruited as the experimental group. They completed questionnaires in the preoperative, postoperative chemoradiotherapy and rehabilitation periods, respectively.101 healthy female volunteers recruited from the community were included as control group, whose age and level of education were matched with those of the experimental group.The general questionnaire including basic information, disease conditions and other projects, perceived social support scale (PSSS), quality of life of breast cancer patients (FACT-B) were applied to evaluate the general situation, social support and QOL of the subjects. The differences in PSSS scores between the experimental and control groups were compared. The correlation between PSSS score and FACT-B score in the experimental group was analyzed. SPSS 18.0 software was used for statistical analysis. Results: The general situations of the experimental and control groups were comparable (all P >0.05). The rates of the total social support score ≥50 in the experimental and control groups were not significantly different (93.6% vs. 94.7%, P =0.067). Compared with that of the control group (23.2±4.8), the scores of family support in the experimental group in preoperative, postoperative chemoradiotherapy and rehabilitation periods were statistically higher (25.6±3.2, 24.2±4.2 and 24.0±3.4, respectively, P =0.034). The social support scores of patients with different demographic characteristics were different. Among the demographic characteristics, years of education and place of residence had the largest impact. The scores of social support in patients with longer education years and living in the

  12. [Strategies and development of quality assurance and control in the ELSA-Brasil].

    Science.gov (United States)

    Schmidt, Maria Inês; Griep, Rosane Härter; Passos, Valéria Maria; Luft, Vivian Cristine; Goulart, Alessandra Carvalho; Menezes, Greice Maria de Souza; Molina, Maria del Carmen Bisi; Vigo, Alvaro; Nunes, Maria Angélica

    2013-06-01

    The ELSA-Brasil (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health) is a cohort study composed of 15,105 adults followed up in order to assess the development of chronic diseases, especially diabetes and cardiovascular disease. Its size, multicenter nature and the diversity of measurements required effective and efficient mechanisms of quality assurance and control. The main quality assurance activities (those developed before data collection) were: careful selection of research instruments, centralized training and certification, pretesting and pilot studies, and preparation of operation manuals for the procedures. Quality control activities (developed during data collection and processing) were performed more intensively at the beginning, when routines had not been established yet. The main quality control activities were: periodic observation of technicians, test-retest studies, data monitoring, network of supervisors, and cross visits. Data that estimate the reliability of the obtained information attest that the quality goals have been achieved.

  13. Effect of a period of aquatic exercise therapy on the quality of life, anxiety and depression in patients with hemophilia

    Directory of Open Access Journals (Sweden)

    Mehdi Kargarfard

    2011-07-01

    Full Text Available Introduction: Muscle-Skeletal disorders are the most common problems in hemophilia patients that can affect the quality of life and psychological factors in these patients. The aim of this study was to evaluate the effect of a period of aquatic exercise therapy on the quality of life, depression and anxiety in hemophilia patients. Materials and Methods: In a semi-experimental study, 20 patients who referred to Isfahan Sayedo-Shohada hospital voluntarily were selected and then randomly in two experimental (n=10 and control (n=10 groups. Subjects of aquatic exercise therapy group started their activity in water for 8 weeks, 3 sessions per week about45 to 60 minutes, while the control group was only followed-up and during this period they did not experience any exercise. The quality of life, depression and anxiety variables of patients were measured by standard questionnaires in the beginning and end of eight week aquatic exercise therapy. Results: The results showed significant improvement in quality of life, depression and anxiety variables in aquatic exercise therapy group patients, compared with the control group after 8 week aquatic exercise therapy (p<0.05. Conclusion: Results of this study showed that aquatic exercise therapy can be used as an effective and helpful method to prevent and treat hemophilia patients because it leads to improve multi-dimensional variable quality of life, depression and anxiety in hemophilia patients .

  14. Quality assurance and quality control of nuclear engineering during construction phase

    International Nuclear Information System (INIS)

    Zhang Zhihua; Deng Yue; Liu Yaoguang; Xu Xianqi; Zhou Shan; Qian Dazhi; Zhang Yang

    2007-01-01

    The quality assurance (QA) and quality control (QC) is a very important work in the nuclear engineering. This paper starts with how to establish quality assurance system of nuclear engineering construction phase, then introduces several experiments and techniques such as the implementation of quality assurance program, the quality assurance and quality control of contractors, the quality surveillance and control of supervisory companies, quality assurance audit and surveillance of builders. (authors)

  15. Implementation of basic quality control tests for malaria medicines in Amazon Basin countries: results for the 2005–2010 period

    Directory of Open Access Journals (Sweden)

    Pribluda Victor S

    2012-06-01

    Full Text Available Abstract Background Ensuring the quality of malaria medicines is crucial in working toward malaria control and eventual elimination. Unlike other validated tests that can assess all critical quality attributes, which is the standard for determining the quality of medicines, basic tests are significantly less expensive, faster, and require less skilled labour; yet, these tests provide reproducible data and information on several critical quality attributes, such as identity, purity, content, and disintegration. Visual and physical inspection also provides valuable information about the manufacturing and the labelling of medicines, and in many cases this inspection is sufficient to detect counterfeit medicines. The Promoting the Quality of Medicines (PQM programme has provided technical assistance to Amazon Malaria Initiative (AMI countries to implement the use of basic tests as a key screening mechanism to assess the quality of malaria medicines available to patients in decentralized regions. Methods Trained personnel from the National Malaria Control Programmes (NMCPs, often in collaboration with country’s Official Medicine Control Laboratory (OMCL, developed country- specific protocols that encompassed sampling methods, sample analysis, and data reporting. Sampling sites were selected based on malaria burden, accessibility, and geographical location. Convenience sampling was performed and countries were recommended to store the sampled medicines under conditions that did not compromise their quality. Basic analytical tests, such as disintegration and thin layer chromatography (TLC, were performed utilizing a portable mini-laboratory. Results Results were originally presented at regional meetings in a non-standardized format that lacked relevant medicines information. However, since 2008 information has been submitted utilizing a template specifically developed by PQM for that purpose. From 2005 to 2010, the quality of 1,663 malaria medicines

  16. 40 CFR 51.359 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  17. Importance of implementing an analytical quality control system in a core laboratory.

    Science.gov (United States)

    Marques-Garcia, F; Garcia-Codesal, M F; Caro-Narros, M R; Contreras-SanFeliciano, T

    2015-01-01

    The aim of the clinical laboratory is to provide useful information for screening, diagnosis and monitoring of disease. The laboratory should ensure the quality of extra-analytical and analytical process, based on set criteria. To do this, it develops and implements a system of internal quality control, designed to detect errors, and compare its data with other laboratories, through external quality control. In this way it has a tool to detect the fulfillment of the objectives set, and in case of errors, allowing corrective actions to be made, and ensure the reliability of the results. This article sets out to describe the design and implementation of an internal quality control protocol, as well as its periodical assessment intervals (6 months) to determine compliance with pre-determined specifications (Stockholm Consensus(1)). A total of 40 biochemical and 15 immunochemical methods were evaluated using three different control materials. Next, a standard operation procedure was planned to develop a system of internal quality control that included calculating the error of the analytical process, setting quality specifications, and verifying compliance. The quality control data were then statistically depicted as means, standard deviations, and coefficients of variation, as well as systematic, random, and total errors. The quality specifications were then fixed and the operational rules to apply in the analytical process were calculated. Finally, our data were compared with those of other laboratories through an external quality assurance program. The development of an analytical quality control system is a highly structured process. This should be designed to detect errors that compromise the stability of the analytical process. The laboratory should review its quality indicators, systematic, random and total error at regular intervals, in order to ensure that they are meeting pre-determined specifications, and if not, apply the appropriate corrective actions

  18. Critical Period of Weed Control in Aerobic Rice

    Science.gov (United States)

    Anwar, M. P.; Juraimi, A. S.; Samedani, B.; Puteh, A.; Man, A.

    2012-01-01

    Critical period of weed control is the foundation of integrated weed management and, hence, can be considered the first step to design weed control strategy. To determine critical period of weed control of aerobic rice, field trials were conducted during 2010/2011 at Universiti Putra Malaysia. A quantitative series of treatments comprising two components, (a) increasing duration of weed interference and (b) increasing length of weed-free period, were imposed. Critical period was determined through Logistic and Gompertz equations. Critical period varied between seasons; in main season, it started earlier and lasted longer, as compared to off-season. The onset of the critical period was found relatively stable between seasons, while the end was more variable. Critical period was determined as 7–49 days after seeding in off-season and 7–53 days in main season to achieve 95% of weed-free yield, and 23–40 days in off-season and 21–43 days in main season to achieve 90% of weed-free yield. Since 5% yield loss level is not practical from economic view point, a 10% yield loss may be considered excellent from economic view point. Therefore, aerobic rice should be kept weed-free during 21–43 days for better yield and higher economic return. PMID:22778701

  19. Network-based production quality control

    Science.gov (United States)

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  20. Controller Synthesis for Periodically Forced Chaotic Systems

    Science.gov (United States)

    Basso, Michele; Genesio, Roberto; Giovanardi, Lorenzo

    Delayed feedback controllers are an appealing tool for stabilization of periodic orbits in chaotic systems. Despite their conceptual simplicity, specific and reliable design procedures are difficult to obtain, partly also because of their inherent infinite-dimensional structure. This chapter considers the use of finite dimensional linear time invariant controllers for stabilization of periodic solutions in a general class of sinusoidally forced nonlinear systems. For such controllers — which can be interpreted as rational approximations of the delayed ones — we provide a computationally attractive synthesis technique based on Linear Matrix Inequalities (LMIs), by mixing results concerning absolute stability of nonlinear systems and robustness of uncertain linear systems. The resulting controllers prove to be effective for chaos suppression in electronic circuits and systems, as shown by two different application examples.

  1. Quality control of MC and A system and integrated safeguards

    International Nuclear Information System (INIS)

    Osabe, Takeshi

    2000-01-01

    In the integrated safeguards regime, co-operation with SSAC is a vital element to achieve efficiency of safeguards implementation while maintaining the effectiveness. However, the degree of co-operation fully depends upon the credibility, technical capability and the transparency of SSAC. Since the credibility of SSAC (States' System of Accounting for and Control of Nuclear Materials) depends heavily on effectiveness of facility operator's Material Control and Accounting (MC and A) practice, some measures to provide continuous assurance of the function and effectiveness of the system such as quality assurance program including periodical system audit (diagnostic) function ought to be established. This paper discusses quality assurance program for facility level MC and A including audit (diagnostic) method to maintain continuous assurance of the effectiveness. (author)

  2. Radiopharmaceutical quality control-Pragmatic approach

    International Nuclear Information System (INIS)

    Barbier, Y.

    1994-01-01

    The quality control must be considered in a practical manner. The radiopharmaceuticals are drugs. They must satisfy the quality assurance control. These products are then conform to Pharmacopeia. But sometimes the user must control some data especially radiochemical purity and pH value. On all the administered solutions four controls are compulsory: radionuclide identity, administered radioactivity, organoleptic character and pH

  3. 7 CFR 981.42 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  4. Quality control of dosemeters

    International Nuclear Information System (INIS)

    Mendes, L.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are acomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintilation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (Author) [pt

  5. Control cards as a statistical quality control resource

    Directory of Open Access Journals (Sweden)

    Aleksandar Živan Drenovac

    2013-02-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 This paper proves that applying of statistical methods can significantly contribute increasing of products and services quality, as well as increasing of institutions rating. Determining of optimal, apropos anticipatory and limitary values, is based on sample`s statistical analyze. Control cards represent very confident instrument, which is simple for use and efficient for control of process, by which process is maintained in set borders. Thus, control cards can be applied in quality control of procesess of weapons and military equipment production, maintenance of technical systems, as well as for seting of standards and increasing of quality level for many other activities.

  6. 7 CFR 930.44 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  7. Quality control analysis at the hospital

    International Nuclear Information System (INIS)

    Kristensen, K.

    1979-01-01

    Quality control analysis is an integral part of quality assurance. In a system as with radiopharmaceuticals where part of the finishing of the product takes place at individual hospitals, the need for quality control analysis at the hospital can be discussed. Data are presented that stresses the importance of quality control by the manufacturer as a basis for limitation of such work at hospitals. A simplified programme is proposed

  8. 14 CFR 21.139 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which he...

  9. 33 CFR 385.21 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  10. Research on goal-setting method of rock drivage based on the balance among period, cost and quality

    Institute of Scientific and Technical Information of China (English)

    SHAN Ren-liang; CAI Wei-ling; WANG Yu-bao; LI Dong-gang; CHEN Xiang

    2012-01-01

    On the basis of the analysis on the disadvantages of the original goal-serting about rock drivage,this paper defined the "life cycle quality".With project management theory and the Cobb-Douglas finction,"quality-cost and quality-price curve model" and the "total cost-period prediction model" were built.Then the goal-setting method of the balance among quality,cost and period of rock drivage was constructed by finding "life cycle cost" through "life cycle quality" using "quality-cost andquality-price curve model" and ensuring period through "life cycle cost" using "total cost-period prediction model" (hereinafter referred to as the "three goals balance method")."Value contribution" which is the value of the contribution to a mine because of rock drivage,was found in the process of constructing the "quality-cost and quality-price curve model".An industrial test was done in coal mine A with the research results,staff footage efficiency improved by 24.24%,the period shortened by 14.3%,the "life cycle cost" dropped by 2.09%,the "life cycle quality price" improved by 3.29%,and value contribution increased by 25.3%.The result shows that the new goal method setting on the basis of coal mine profit maximization can ensure construction period.At the same time,it can realize cost and quality objectives and the optimization and balance of relationship among them; rewarding excavation teams by "value contribution" can combine organizational goal with personal goal,it significantly raise the employee's work efficiency.

  11. Related regulation of quality control of industrial products

    International Nuclear Information System (INIS)

    1983-04-01

    This book introduce related regulation of quality control of industrial products, which includes regulations of industrial products quality control, enforcement ordinance of industrial products quality control, enforcement regulation of quality control of industrial products, designated items with industrial production quality indication, industrial production quality test, and industrial production quality test organization and management tips of factory quality by grade.

  12. Longer rest periods for intensive rotational grazing limit diet quality ...

    African Journals Online (AJOL)

    Longer rest periods for intensive rotational grazing limit diet quality of sheep without enhancing environmental benefits. ... This experiment was established to compare three intensive rotational grazing strategies (fast rotation [FR], average 57-day rest; slow rotation [SR], average 114-day rest; and flexible grazing [FX], based ...

  13. Quality and reliability control on assemblies

    International Nuclear Information System (INIS)

    Mueller, H.

    1976-01-01

    Taking as an example electronic assemblies in printed circuit board engineering, quality control during manufacture is dealt with. After giving a survey of four phases of quality and reliability control, some specific methods of quality control are dealt with by means of a flowchart, and by some examples the necessity and the success of these measures are shown. (RW) [de

  14. Ambient air quality monitoring during the H1N1 influence period in Pune (India).

    Science.gov (United States)

    Pathak, M; Deshpande, A; Mirashe, P K; Sorte, R B; Ojha, A

    2010-10-01

    Ambient air quality in an urban area is directly linked with activity level in the city including transport, business and industrial activities. Maharashtra Pollution Control Board (MPCB) has established an ambient air quality network in the city including state-of-the-art continuous air quality monitoring stations which indicate short duration air quality variations for criteria and non-criteria pollutants. The influence of H1N1 outbreak in Pune hitting its worst pandemic condition, led the civic authorities to implement stringent isolation measures including closure of schools, colleges, business malls, cinema halls, etc. Additionally, the fear of such a pandemic brought the city to a stand still. It was therefore necessary to assess the impacts of such activity level on ambient air quality in the city. It has been observed that such events have positive impacts on air quality of the city. There was a decrease in PM concentration almost to the tune of 30 to 40% if the impacts of precipitation, i.e. seasonal variations, are taken into account. Similarly, the non criteria pollutants too showed a marked but unusual decrease in their concentrations in this ever growing city. The influence of these in turn led to lowered concentrations of secondary pollutants, i.e. O3. Overall, the ambient air quality of Pune was found to be improved during the study period.

  15. Quality Control in Mammography: Image Quality and Patient Doses

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Arandjic, D.; Boris Loncar, B.; Kosutic, D.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. The purpose of this paper is preliminary evaluation the mammography practice in Serbia, in terms of both quality control indicators, i.e. image quality and patient doses. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Correlation between image contrast and mean glandular doses was demonstrated. Systematic implementation of quality control protocol should provide satisfactory performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practicable. (author)

  16. VGI QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    C. C. Fonte

    2015-08-01

    Full Text Available This paper presents a framework for considering quality control of volunteered geographic information (VGI. Different issues need to be considered during the conception, acquisition and post-acquisition phases of VGI creation. This includes items such as collecting metadata on the volunteer, providing suitable training, giving corrective feedback during the mapping process and use of control data, among others. Two examples of VGI data collection are then considered with respect to this quality control framework, i.e. VGI data collection by National Mapping Agencies and by the most recent Geo-Wiki tool, a game called Cropland Capture. Although good practices are beginning to emerge, there is still the need for the development and sharing of best practice, especially if VGI is to be integrated with authoritative map products or used for calibration and/or validation of land cover in the future.

  17. 7 CFR 58.928 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...

  18. Expert database system for quality control

    Science.gov (United States)

    Wang, Anne J.; Li, Zhi-Cheng

    1993-09-01

    There are more competitors today. Markets are not homogeneous they are fragmented into increasingly focused niches requiring greater flexibility in the product mix shorter manufacturing production runs and above allhigher quality. In this paper the author identified a real-time expert system as a way to improve plantwide quality management. The quality control expert database system (QCEDS) by integrating knowledge of experts in operations quality management and computer systems use all information relevant to quality managementfacts as well as rulesto determine if a product meets quality standards. Keywords: expert system quality control data base

  19. Controllability of multi-agent systems with periodically switching topologies and switching leaders

    Science.gov (United States)

    Tian, Lingling; Zhao, Bin; Wang, Long

    2018-05-01

    This paper considers controllability of multi-agent systems with periodically switching topologies and switching leaders. The concept of m-periodic controllability is proposed, and a criterion for m-periodic controllability is established. The effect of the duration of subsystems on controllability is analysed by utilising a property of analytic functions. In addition, the influence of switching periods on controllability is investigated, and an algorithm is proposed to search for the fewest periods to ensure controllability. A necessary condition for m-periodic controllability is obtained from the perspective of eigenvectors of the subsystems' Laplacian matrices. For a system with switching leaders, it is proved that switching-leader controllability is equivalent to multiple-leader controllability. Furthermore, both the switching order and the tenure of agents being leaders have no effect on the controllability. Some examples are provided to illustrate the theoretical results.

  20. 7 CFR 58.335 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow...

  1. Groundwater-quality data in 12 GAMA study units: Results from the 2006–10 initial sampling period and the 2008–13 trend sampling period, California GAMA Priority Basin Project

    Science.gov (United States)

    Mathany, Timothy M.

    2017-03-09

    The Priority Basin Project (PBP) of the Groundwater Ambient Monitoring and Assessment (GAMA) program was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey in cooperation with the California State Water Resources Control Board. From 2004 through 2012, the GAMA-PBP collected samples and assessed the quality of groundwater resources that supply public drinking water in 35 study units across the State. Selected sites in each study unit were sampled again approximately 3 years after initial sampling as part of an assessment of temporal trends in water quality by the GAMA-PBP. Twelve of the study units, initially sampled during 2006–11 (initial sampling period) and sampled a second time during 2008–13 (trend sampling period) to assess temporal trends, are the subject of this report.The initial sampling was designed to provide a spatially unbiased assessment of the quality of untreated groundwater used for public water supplies in the 12 study units. In these study units, 550 sampling sites were selected by using a spatially distributed, randomized, grid-based method to provide spatially unbiased representation of the areas assessed (grid sites, also called “status sites”). After the initial sampling period, 76 of the previously sampled status sites (approximately 10 percent in each study unit) were randomly selected for trend sampling (“trend sites”). The 12 study units sampled both during the initial sampling and during the trend sampling period were distributed among 6 hydrogeologic provinces: Coastal (Northern and Southern), Transverse Ranges and Selected Peninsular Ranges, Klamath, Modoc Plateau and Cascades, and Sierra Nevada Hydrogeologic Provinces. For the purposes of this trend report, the six hydrogeologic provinces were grouped into two hydrogeologic regions based on location: Coastal and Mountain.The groundwater samples were analyzed for a number of synthetic organic

  2. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Verdera, E.S.

    1994-01-01

    The quality control of radiopharmaceuticals is based in physics, physics-chemical and biological controls. Between the different controls can be enumerated the following: visual aspect,side, number of particle beams,activity,purity,ph,isotonicity,sterility,radioinmunoessay,toxicity,stability and clinical essay

  3. Application of an EPID for fast daily dosimetric quality control of a fully computer-controlled treatment unit

    Energy Technology Data Exchange (ETDEWEB)

    Dirkx, M L.P.; Kroonwijk, M; De Boer, J C.J.; Heijmen, B J.M. [Nederlands Kanker Inst. ` Antoni van Leeuwenhoekhuis` , Amsterdam (Netherlands)

    1995-12-01

    The MM50 Racetrack Microtron, suited for sophisticated three-dimensional computer-controlled conformal radiotherapy techniques, is a complex treatment unit in various respects. Therefore, for a number of gantry angles, daily quality control of the absolute output and the profiles of the scanned photon beams in mandatory. A fast method for these daily checks, based on dosimetric measurements with the Philips SRI-100 Electronic Portal Imaging Device, has been developed and tested. Open beams are checked for four different gantry angles; for gantry angle 0, a wedged field is checked as well. The fields are set up one after another under full computer control. Performing and analyzing the measurements takes about ten minutes. The applied EPID has favourable characteristics for dosimetric quality control measurements: absolute measurements reproduce within 0.5% (1 SD) and the reproducibility of a relative (2-D) fluence profile is 0.2% (1 SD). The day-to-day sensitivity stability over a period of a month is 0.6% (1 SD). EPID-signals are within 0.2% linear with the applied dose. The 2-D fluence profile of the 25 MV photon beam of the MM50 is very stable in time: during a period of one year, a maximum fluctuation of 2.6% was observed. Once, a deviation in the cGy/MU-value of 6% was detected. Only because of the performed morning quality control checks with the EPID, erroneous dose delivery to patients could be avoided; there is no interlock in the MM50-system that would have prevented patient treatment. Based on our experiences and on clinical requirements regarding the acceptability of deviations of beam characteristics, a protocol has been developed including action levels for additional investigations. Studies on the application of the SRI-100 for in vivo dosimetry on the MM50 have been started.

  4. Application of an EPID for fast daily dosimetric quality control of a fully computer-controlled treatment unit

    International Nuclear Information System (INIS)

    Dirkx, M.L.P.; Kroonwijk, M.; De Boer, J.C.J.; Heijmen, B.J.M.

    1995-01-01

    The MM50 Racetrack Microtron, suited for sophisticated three-dimensional computer-controlled conformal radiotherapy techniques, is a complex treatment unit in various respects. Therefore, for a number of gantry angles, daily quality control of the absolute output and the profiles of the scanned photon beams in mandatory. A fast method for these daily checks, based on dosimetric measurements with the Philips SRI-100 Electronic Portal Imaging Device, has been developed and tested. Open beams are checked for four different gantry angles; for gantry angle 0, a wedged field is checked as well. The fields are set up one after another under full computer control. Performing and analyzing the measurements takes about ten minutes. The applied EPID has favourable characteristics for dosimetric quality control measurements: absolute measurements reproduce within 0.5% (1 SD) and the reproducibility of a relative (2-D) fluence profile is 0.2% (1 SD). The day-to-day sensitivity stability over a period of a month is 0.6% (1 SD). EPID-signals are within 0.2% linear with the applied dose. The 2-D fluence profile of the 25 MV photon beam of the MM50 is very stable in time: during a period of one year, a maximum fluctuation of 2.6% was observed. Once, a deviation in the cGy/MU-value of 6% was detected. Only because of the performed morning quality control checks with the EPID, erroneous dose delivery to patients could be avoided; there is no interlock in the MM50-system that would have prevented patient treatment. Based on our experiences and on clinical requirements regarding the acceptability of deviations of beam characteristics, a protocol has been developed including action levels for additional investigations. Studies on the application of the SRI-100 for in vivo dosimetry on the MM50 have been started

  5. 7 CFR 58.642 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.642 Section 58.642... Procedures § 58.642 Quality control tests. All mix ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow line samples as...

  6. Quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Mould, R.F.

    1983-09-01

    The proceedings of a conference held by the Hospital Physicists' Association in London 1983 on the quality control of nuclear medicine instrumentation are presented. Section I deals with the performance of the Anger gamma camera including assessment during manufacture, acceptance testing, routine testing and long-term assessment of results. Section II covers interfaces, computers, the quality control problems of emission tomography and the quality of software. Section III deals with radionuclide measurement and impurity assessment and Section IV the presentation of images and the control of image quality. (U.K.)

  7. Control by quality: proposition of a typology.

    Science.gov (United States)

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  8. INFORMATION SYSTEM QUALITY CONTROL KNOWLEDGE

    Directory of Open Access Journals (Sweden)

    Vladimir Nikolaevich Babeshko

    2017-02-01

    Full Text Available The development of the educational system is associated with the need to control the quality of educational services. Quality control knowledge is an important part of the scientific process. The penetration of computers into all areas of activities changing approaches and technologies that previously they were used.

  9. Combating dephasing decoherence by periodically performing tracking control and projective measurement

    International Nuclear Information System (INIS)

    Zhang Ming; Dai Hongyi; Xi Zairong; Xie Hongwei; Hu Dewen

    2007-01-01

    We propose a scheme to overcome phase damping decoherence by periodically performing open loop tracking control and projective measurement. Although it is impossible to stabilize a qubit subject to Markovian dynamics only by open loop coherent control, one can attain a 'softened' control goal with the help of periodical projective measurement. The 'softened' control objective in our scheme is to keep the state of the controlled qubit to stay near a reference pure state with a high probability for a sufficiently long time. Two suboptimal control problems are given in the sense of trace distance and fidelity, respectively, and they are eventually reduced to the design of a period T. In our scheme, one can choose the period T as long as possible if the 'softened' control goal is attained. This is in contrast to the observation that quantum Zeno effect takes place only if measurements are performed in a very frequent manner, i.e., the period T must be extremely small

  10. 40 CFR 60.4172 - Out of control periods.

    Science.gov (United States)

    2010-07-01

    ... monitoring system fails to meet the quality-assurance and quality-control requirements or data validation... in subpart D of part 75 of this chapter. (b) Audit decertification. Whenever both an audit of a... the time of the audit, the permitting authority will issue a notice of disapproval of the...

  11. 2. Product quality control and assurance system

    International Nuclear Information System (INIS)

    1990-01-01

    Product quality control and assurance are dealt with in relation to reliability in nuclear power engineering. The topics treated include product quality control in nuclear power engineering, product quality assurance of nuclear power plant equipment, quality assurance programs, classification of selected nuclear power equipment, and standards relating to quality control and assurance and to nuclear power engineering. Particular attention is paid to Czechoslovak and CMEA standards. (P.A.). 2 figs., 1 tab., 12 refs

  12. Effects of Packaging on Shelf Life and Postharvest Qualities of Radish Roots during Storage at Low Temperature for an Extended Period

    Directory of Open Access Journals (Sweden)

    Dulal Chandra

    2018-01-01

    Full Text Available To investigate the effects of packaging on the quality aspects of radish, Korean radish roots (Raphanus sativus L. var. Kwandong were stored at 0°C after different packaging treatments such as keeping in paper cartoon box (control, keeping in plastic crates (PC, packaging with micro perforated HDPE film in PC (HDPE + PC, curing followed by keeping in PC (Curing + PC, and curing followed by packaging with micro perforated HDPE film in PC (Curing + HDPE + PC. Weight losses of radish roots were remarkably lower (<3% in both HDPE film packaged samples compared to that of control (10% or without film (≈18%. L⁎ values, whiteness index, total soluble solids, and flesh and skin firmness were better maintained in Curing + HDPE + PC treatment compared to other treatments. Lower color difference values were also found in this treatment. Both film packaged samples had lower scores of black spot, surface shrinkage, and fungal infection incidence which revealed significantly longer marketable periods. HDPE film packaged samples exhibited longer shelf life more than one and two months compared to control and unpacked samples, respectively. Results suggest that HDPE film packaging can extend postharvest life of radish while curing might have little but beneficial effects in maintaining the quality characteristics. To our knowledge, this is the first report on quality evaluation of Korean radish during an extended storage period simulating the Korean industrial practices.

  13. Determination and evaluation of air quality control. Manual of ambient air quality control in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Lahmann, E.

    1997-07-01

    Measurement of air pollution emissions and ambient air quality are essential instruments for air quality control. By undertaking such measurements, pollutants are registered both at their place of origin and at the place where they may have an effect on people or the environment. Both types of measurement complement each other and are essential for the implementation of air quality legislation, particularly, in compliance with emission and ambient air quality limit values. Presented here are similar accounts of measurement principles and also contains as an Appendix a list of suitability-tested measuring devices which is based on information provided by the manufacturers. In addition, the guide of ambient air quality control contains further information on discontinuous measurement methods, on measurement planning and on the assessment of ambient air quality data. (orig./SR)

  14. Reporting quality of randomized controlled trial abstracts: survey of leading general dental journals.

    Science.gov (United States)

    Hua, Fang; Deng, Lijia; Kau, Chung How; Jiang, Han; He, Hong; Walsh, Tanya

    2015-09-01

    The authors conducted a study to assess the reporting quality of randomized controlled trial (RCT) abstracts published in leading general dental journals, investigate any improvement after the release of the Consolidated Standards of Reporting Trials (CONSORT) for Abstracts guidelines, and identify factors associated with better reporting quality. The authors searched PubMed for RCTs published in 10 leading general dental journals during the periods from 2005 to 2007 (pre-CONSORT period) and 2010 to 2012 (post-CONSORT period). The authors evaluated and scored the reporting quality of included abstracts by using the original 16-item CONSORT for Abstracts checklist. The authors used risk ratios and the t test to compare the adequate reporting rate of each item and the overall quality in the 2 periods. The authors used univariate and multivariate regressions to identify predictors of better reporting quality. The authors included and evaluated 276 RCT abstracts. Investigators reported significantly more checklist items during the post-CONSORT period (mean [standard deviation {SD}], 4.53 [1.69]) than during the pre-CONSORT period (mean [SD], 3.87 [1.10]; mean difference, -0.66 [95% confidence interval, -0.99 to -0.33]; P 80%). In contrast, the authors saw sufficient reporting of randomization, recruitment, outcome in the results section, and funding in none of the pre-CONSORT abstracts and less than 2% of the post-CONSORT abstracts. On the basis of the multivariate analysis, a higher impact factor (P general dental journals has improved significantly, but there is still room for improvement. Joint efforts by authors, reviewers, journal editors, and other stakeholders to improve the reporting of dental RCT abstracts are needed. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  15. 30 CFR 74.6 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6 Quality...

  16. Using a statistical process control chart during the quality assessment of cancer registry data.

    Science.gov (United States)

    Myles, Zachary M; German, Robert R; Wilson, Reda J; Wu, Manxia

    2011-01-01

    Statistical process control (SPC) charts may be used to detect acute variations in the data while simultaneously evaluating unforeseen aberrations that may warrant further investigation by the data user. Using cancer stage data captured by the Summary Stage 2000 (SS2000) variable, we sought to present a brief report highlighting the utility of the SPC chart during the quality assessment of cancer registry data. Using a county-level caseload for the diagnosis period of 2001-2004 (n=25,648), we found the overall variation of the SS2000 variable to be in control during diagnosis years of 2001 and 2002, exceeded the lower control limit (LCL) in 2003, and exceeded the upper control limit (UCL) in 2004; in situ/localized stages were in control throughout the diagnosis period, regional stage exceeded UCL in 2004, and distant stage exceeded the LCL in 2001 and the UCL in 2004. Our application of the SPC chart with cancer registry data illustrates that the SPC chart may serve as a readily available and timely tool for identifying areas of concern during the data collection and quality assessment of central cancer registry data.

  17. [Quality control in herbal supplements].

    Science.gov (United States)

    Oelker, Luisa

    2005-01-01

    Quality and safety of food and herbal supplements are the result of a whole of different elements as good manufacturing practice and process control. The process control must be active and able to individuate and correct all possible hazards. The main and most utilized instrument is the hazard analysis critical control point (HACCP) system the correct application of which can guarantee the safety of the product. Herbal supplements need, in addition to standard quality control, a set of checks to assure the harmlessness and safety of the plants used.

  18. Distributed sensor architecture for intelligent control that supports quality of control and quality of service.

    Science.gov (United States)

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-02-25

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  19. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    Directory of Open Access Journals (Sweden)

    Jose-Luis Poza-Lujan

    2015-02-01

    Full Text Available This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS parameters and the optimization of control using Quality of Control (QoC parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS communication standard as proposed by the Object Management Group (OMG. As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  20. Quality control education in the community college

    Science.gov (United States)

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  1. TRAINING SYSTEM OF FUTURE SPECIALISTS: QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Vladimir A. Romanov

    2015-01-01

    Full Text Available The aim of the investigation is development of innovative strategy of quality control training of engineers and skilled workers (hereinafter – future specialists in educational professional organizations on the principles of social partnership.Methods. Theoretic: theoretic and methodological analysis, polytheoretic synthesis, modeling. Empirical: research and generalization of the system, process and competence – based approaches experience, experiment, observation, surveys, expert evaluation, SWOT-analysis as a method of strategic planning which is to identify the internal and external factors (socio-cultural of the organization surrounding.Results. The strategy of the development of the process of quality control training in educational professional organizations and a predictive model of the system of quality control training for future engineers and workers have been created on the analysis and synthesis of a quantitative specification of the quality, the obtained experience and success in control training of future specialists in educational professional organizations in recent economic and educational conditions.Scientific novelty. There has been built a predicative model of quality control training of future specialists to meet modern standards and the principles of social partnership; the control algorithm of the learning process, developed in accordance with the standards (international of quality ISO in the implementation of the quality control systems of the process approach (matrix-based responsibility, competence and remit of those responsible for the education process in the educational organization, the «problem» terms and diagnostic tools for assessing the quality of professional training of future specialists. The perspective directions of innovation in the control of the quality of future professionals training have been determined; the parameters of a comprehensive analysis of the state of the system to ensure the

  2. Analysis of quality control protocol implementation of equipment in radiotherapy services

    International Nuclear Information System (INIS)

    Calcina, Carmen S. Guzman; Lima, Luciana P. de; Rubo, Rodrigo A.; Ferraz, Eduardo; Almeida, Adelaide de

    2000-01-01

    Considering the importance of the Quality Assurance in the radiotherapy services, there was an interest to make tests' evaluation for a Quality Control for the cobalt equipment, linear accelerator and simulator as a classification and comparison. The work proposed is a suggestion that can serve as tool for medical physicists that are starting to work in the radiotherapy area and for the most experts. The discussions were made by the gathering of local tests and official protocols, resulting in a minimum protocol as a suggestion for a routine work, emphasizing the periodicity and level of tolerance of each one of the tests. (author)

  3. 14 CFR 145.211 - Quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...

  4. 18 CFR 12.40 - Quality control programs.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program is...

  5. Developing methods of controlling quality costs

    Directory of Open Access Journals (Sweden)

    Gorbunova A. V.

    2017-01-01

    Full Text Available The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding evaluation criteria in the quality management system of enterprises is introduced. Authors also introduce the method of controlling quality costs and propose it for the practical application, which allows them to determine useful and unnecessary costs at the existing operating plant. Implementing the proposed recommendations in the system of cost management at an enterprise will allow to improve productivity of processes operating and reduce wasted expense on the quality of the process on the basis of determining values of useful and useless costs of quality according to criteria of processes functioning in the system of quality management.

  6. Computer controlled quality of analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.; Huff, G.A.

    1979-01-01

    A PDP 11/35 computer system is used in evaluating analytical chemistry measurements quality control data at the Barnwell Nuclear Fuel Plant. This computerized measurement quality control system has several features which are not available in manual systems, such as real-time measurement control, computer calculated bias corrections and standard deviation estimates, surveillance applications, evaluaton of measurement system variables, records storage, immediate analyst recertificaton, and the elimination of routine analysis of known bench standards. The effectiveness of the Barnwell computer system has been demonstrated in gathering and assimilating the measurements of over 1100 quality control samples obtained during a recent plant demonstration run. These data were used to determine equaitons for predicting measurement reliability estimates (bias and precision); to evaluate the measurement system; and to provide direction for modification of chemistry methods. The analytical chemistry measurement quality control activities represented 10% of the total analytical chemistry effort

  7. Quality assurance, quality control and quality audit in diagnostic radiology

    International Nuclear Information System (INIS)

    Vassileva, J.

    2009-01-01

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  8. Assessment of water quality of the Tisa River (Vojvodina, North Serbia for ten year period using Serbian water quality index (SWQI

    Directory of Open Access Journals (Sweden)

    Leščešen Igor

    2014-01-01

    Full Text Available The WQI method is most frequently used in expert and scientific research and basically it provides a mechanism for cumulative representation, numeric expression and defining a certain level of water quality. This paper aims to assess water quality of the Tisa River in Vojvodina (North Serbia for the 2003 - 2012 period. Serbian Water Quality Index (SWQI was used for assessment of the river water quality. WQI is expressed as a single value ranging from 0 to 100 (best quality derived from numerous physical, chemical, biological and microbiological parameters. The results of SWQI for the Tisa River were mainly rated as good. Also, in this study it is noticed a clear decrease in water quality during warmer period of the year. Also, this study shows that water quality along the Tisa River decreases slightly but steadily down- stream, from Martonoš to Titel station and all along the length of the river provides values that according to SWQI descriptive quality indicator has been defined as good (72-83. The main problem of SWQI used in this paper is that it does not involve parameters of heavy metals concentration.

  9. Employee quality, monitoring environment and internal control

    Directory of Open Access Journals (Sweden)

    Chunli Liu

    2017-03-01

    Full Text Available We investigate the effect of internal control employees (ICEs on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX, have higher institutional ownership or attach greater importance to internal control. Our findings suggest that ICEs play an important role in the design and implementation of internal control systems. Our study should be of interest to both top managers who wish to improve corporate internal control quality and regulators who wish to understand the mechanisms of internal control monitoring.

  10. Using a tandem ionization chamber for quality control of X-ray beams

    International Nuclear Information System (INIS)

    Yoshizumi, Maira T.; Caldas, Linda V.E.

    2011-01-01

    X-ray beam qualities are defined by both the mean energies and by the half-value layers (HVL). Many international protocols use the half-value layer and the beam voltage to characterize the X-ray beam quality. A quality control program for X-ray equipment includes the constancy check of beam qualities, i.e., the periodical verification of the half-value layer, which can be a time consumable procedure. A tandem ionization chamber, developed at Instituto de Pesquisas Energeticas e Nucleares, was used to determine the HVL and its constancy for five radiotherapy standard beam qualities. This ionization chamber is composed by two sensitive volumes with inner electrodes made of different materials: aluminum and graphite. The beam quality constancy check test was performed during two months and the maximum variation obtained was 1.24% for the radiation beam quality T-10. This result is very satisfactory according to national recommendations. (author)

  11. Problems of quality assurance and quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1986-01-01

    Topical problems of quality assurance and quality control in diagnostic radiology are discussed and possible solutions are shown. Complex units are differentiated with reference to physicians, technicians, organization of labour, methods of examination and indication. Quality control of radiologic imaging systems should involve three stages: (1) simple tests carried out by radiologic technicians, (2) measurements by service technicians, (3) testing of products by the manufacturer and independent governmental or health service test agencies. (author)

  12. Quality Control in construction.

    Science.gov (United States)

    1984-01-01

    behavioral scientists. In 1962, Dr. Kaoru Ishikawa gave shape to the form of training which featured intradepartmental groups of ten or so workers seated...and Japanese circles bears closer scrutiny. 4.3.1 Japanese Ingredients of Quality The founder of quality circles, Dr. Kaoru Ishikawa , gives six...around 51 a table; hence the name Quality Control Circle. 4 Dr. 0 Ishikawa was an engineering professor at Tokyo University, and the circles were

  13. Establishment for quality control of experimental animal

    International Nuclear Information System (INIS)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus

  14. Establishment for quality control of experimental animal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus.

  15. Quality control for dose calibrators

    International Nuclear Information System (INIS)

    Mendes, L.C.G.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are accomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintillation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (author)

  16. Robust sawtooth period control based on adaptive online optimization

    International Nuclear Information System (INIS)

    Bolder, J.J.; Witvoet, G.; De Baar, M.R.; Steinbuch, M.; Van de Wouw, N.; Haring, M.A.M.; Westerhof, E.; Doelman, N.J.

    2012-01-01

    The systematic design of a robust adaptive control strategy for the sawtooth period using electron cyclotron current drive (ECCD) is presented. Recent developments in extremum seeking control (ESC) are employed to derive an optimized controller structure and offer practical tuning guidelines for its parameters. In this technique a cost function in terms of the desired sawtooth period is optimized online by changing the ECCD deposition location based on online estimations of the gradient of the cost function. The controller design does not require a detailed model of the sawtooth instability. Therefore, the proposed ESC is widely applicable to any sawtoothing plasma or plasma simulation and is inherently robust against uncertainties or plasma variations. Moreover, it can handle a broad class of disturbances. This is demonstrated by time-domain simulations, which show successful tracking of time-varying sawtooth period references throughout the whole operating space, even in the presence of variations in plasma parameters, disturbances and slow launcher mirror dynamics. Due to its simplicity and robustness the proposed ESC is a valuable sawtooth control candidate for any experimental tokamak plasma, and may even be applicable to other fusion-related control problems. (paper)

  17. 40 CFR 96.272 - Out of control periods.

    Science.gov (United States)

    2010-07-01

    ... the quality-assurance and quality-control requirements or data validation requirements of part 75 of... appendix D to part 75 of this chapter. (b) Audit decertification. Whenever both an audit of a monitoring... the time of the audit, the permitting authority or, for a CAIR SO2 opt-in unit or a unit for which a...

  18. 42 CFR 84.256 - Quality control requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in paragraphs...

  19. Employee quality, monitoring environment and internal control

    OpenAIRE

    Chunli Liu; Bin Lin; Wei Shu

    2017-01-01

    We investigate the effect of internal control employees (ICEs) on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX), have higher institutional ow...

  20. Predictors of the quality of life of women in peri-menopausal period

    Directory of Open Access Journals (Sweden)

    Katarzyna Kanadys

    2016-09-01

    The quality of life of the peri-menopausal women examined was the highest with respect to depressive mood (DEP and anxiety/depressed mood (ANX, while it was the lowest with respect to the sense of attractiveness (ATT, and somatic symptoms (SOM. In addition, in the group of women in peri-menopausal period the quality of life was conditioned: level of depression, self-reported state of health, occurrence of menopausal symptoms, education level, and marital status.

  1. Quality control with R an ISO standards approach

    CERN Document Server

    Cano, Emilio L; Prieto Corcoba, Mariano

    2015-01-01

    Presenting a practitioner's guide to capabilities and best practices of quality control systems using the R programming language, this volume emphasizes accessibility and ease-of-use through detailed explanations of R code as well as standard statistical methodologies. In the interest of reaching the widest possible audience of quality-control professionals and statisticians, examples throughout are structured to simplify complex equations and data structures, and to demonstrate their applications to quality control processes, such as ISO standards. The volume balances its treatment of key aspects of quality control, statistics, and programming in R, making the text accessible to beginners and expert quality control professionals alike. Several appendices serve as useful references for ISO standards and common tasks performed while applying quality control with R.

  2. Quality control for the equipment of Nuclear medicine: experience of the H.U. de la Princesa

    International Nuclear Information System (INIS)

    Espana, M.L.; Gracia, A.; Prieto, C.; Lopez F, P.

    1998-01-01

    The quality control of the equipment used in a nuclear medicine service is a fundamental aspect in the Quality Assurance Program that in the present time is starting in our hospital. the objective of this work is to present the internal protocol used, its problematic associated with its starting, and the results obtained in the quality control as of the gamma camera as of the activimeter. In addition to the equipment own to the nuclear medicine service it has been used a Cs-137 source and puppets for several purposes. The results obtained demonstrated the stability of the controlled parameters which has led us to a restating of the established periodicities in our internal protocol, over all for some constancy tests. (Author)

  3. A Comparison of Power Quality Controllers

    Directory of Open Access Journals (Sweden)

    Petr Černek

    2012-01-01

    Full Text Available This paper focuses on certain types of FACTS (Flexibile AC Transmission System controllers, which can be used for improving the power quality at the point of connection with the power network. It focuses on types of controllers that are suitable for use in large buildings, rather than in transmission networks. The goal is to compare the features of the controllers in specific tasks, and to clarify which solution is best for a specific purpose. It is in some cases better and cheaper to use a combination of controllers than a single controller. The paper also presents the features of a shunt active harmonic compensator, which is a very modern power quality controller that can be used in many cases, or in combination with other controllers. The comparison was made using a matrix diagram that, resulted from mind mapsand other analysis tools. The paper should help engineers to choose the best solution for improving the power quality in a specific power network at distribution level.

  4. quality control

    International Nuclear Information System (INIS)

    Skujina, A.; Purina, S.; Riekstina, D.

    1999-01-01

    The optimal objects: soils, spruce needles and bracken ferns were found for the environmental monitoring in the regions of possible radioactive contamination - near SalaspiIs nuclear reactor and Ignalina nuclear power plant. The determination of Sr-90 was based on the radiochemical separation of Sr-90 (=Y-90) by HDEHP extraction and counting the Cerenkov radiation. The quality control of the results was carried out. (authors)

  5. Cost-benefit evaluation in a quality control programme for conventional radiodiagnosis

    International Nuclear Information System (INIS)

    Gallini, R.; Belletti, S.; Giugni, U.

    1985-01-01

    A comparison is being made between the cost of the staff and equipment in a quality control programme of conventional radiodiagnosis and the benefit obtained in the reduction of spoilt films and in the reduction of dose to patients and workers. For over two years the programme has followed a protocol verified on about 50 X-ray tubes, 25 radiological devices and four automatic processors. The present research, based on previous data, works on a limited but representative sample of radiological X-ray tubes and accessories. The control procedures are carried out periodically to improve and make constant the efficiency of the radiological devices. An evaluation of the cost of these procedures is made. In the meantime the dose to the patients undergoing radiodiagnostic examinations is evaluated by a transmission chamber. Comparison between the values obtained before and after the control enables the benefits to be evaluated. Rejection of radiographic films is evaluated before and after the control to obtain the cost reduction. During the one year control period, there were no variations in the technical characteristics of the personnel, in the operational procedures or in the work-load. (author)

  6. Demonstration of sawtooth period control with EC waves in KSTAR plasma

    Directory of Open Access Journals (Sweden)

    Jeong J. H.

    2015-01-01

    Full Text Available The sawtooth period control in tokamak is important issue in recent years because the sawtooth crash can trigger TM/NTM instabilities and drive plasmas unstable. The control of sawtooth period by the modification of local current profile near the q=1 surface using ECCD has been demonstrated in a number of tokamaks [1, 2] including KSTAR. As a result, developing techniques to control the sawtooth period as a way of controlling the onset of NTM has been an important area of research in recent years [3]. In 2012 KSTAR plasma campaign, the sawtooth period control is carried out by the different deposition position of EC waves across the q=1 surface. The sawtooth period is shortened by on-axis co-ECCD (destabilization, and the stabilization of the sawtooth is also observed by off-axis co-ECCD at outside q=1 surface. In 2013 KSTAR plasma campaign, the sawtooth locking experiment with periodic forcing of 170 GHz EC wave is carried out to control the sawtooth period. The optimal target position which lengthens the sawtooth period is investigated by performing a scan of EC beam deposition position nearby q=1 surface at the toroidal magnetic field of 2.9 T and plasma current of 0.7 MA. The sawtooth locking by the modulated EC beam is successfully demonstrated as in [3-5] with the scan of modulation-frequency and duty-ratio at the low beta (βN~0.5 plasma. In this paper, the sawteeth behavior by the location of EC beam and the preliminary result of the sawtooth locking experiments in KSTAR will be presented.

  7. Impact of rain gauge quality control and interpolation on streamflow simulation: an application to the Warwick catchment, Australia

    Science.gov (United States)

    Liu, Shulun; Li, Yuan; Pauwels, Valentijn R. N.; Walker, Jeffrey P.

    2017-12-01

    Rain gauges are widely used to obtain temporally continuous point rainfall records, which are then interpolated into spatially continuous data to force hydrological models. However, rainfall measurements and interpolation procedure are subject to various uncertainties, which can be reduced by applying quality control and selecting appropriate spatial interpolation approaches. Consequently, the integrated impact of rainfall quality control and interpolation on streamflow simulation has attracted increased attention but not been fully addressed. This study applies a quality control procedure to the hourly rainfall measurements obtained in the Warwick catchment in eastern Australia. The grid-based daily precipitation from the Australian Water Availability Project was used as a reference. The Pearson correlation coefficient between the daily accumulation of gauged rainfall and the reference data was used to eliminate gauges with significant quality issues. The unrealistic outliers were censored based on a comparison between gauged rainfall and the reference. Four interpolation methods, including the inverse distance weighting (IDW), nearest neighbors (NN), linear spline (LN), and ordinary Kriging (OK), were implemented. The four methods were firstly assessed through a cross-validation using the quality-controlled rainfall data. The impacts of the quality control and interpolation on streamflow simulation were then evaluated through a semi-distributed hydrological model. The results showed that the Nash–Sutcliffe model efficiency coefficient (NSE) and Bias of the streamflow simulations were significantly improved after quality control. In the cross-validation, the IDW and OK methods resulted in good interpolation rainfall, while the NN led to the worst result. In term of the impact on hydrological prediction, the IDW led to the most consistent streamflow predictions with the observations, according to the validation at five streamflow-gauged locations. The OK method

  8. Developing methods of controlling quality costs

    OpenAIRE

    Gorbunova A. V.; Maximova O. N.; Ekova V. A.

    2017-01-01

    The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding eva...

  9. The effect of a mixture of Lactobacillus strains on silage quality and nutritive value of grass harvested at four growth stages and ensiled for two periods

    Directory of Open Access Journals (Sweden)

    Johan De Boever

    2013-03-01

    Full Text Available   The effect of adding an inoculant containing Lactobacillus buchneri, L. plantarum and L. casei to wilted perennial ryegrass, harvested at four growth stages and ensiled for either 60 or 150 d on silage fermentation quality, chemical composition, rumen degradability of neutral detergent fibre (NDF and organic matter (OM and in vitro OM digestibility (OMd was studied. Compared to the control silage, more sugars were fermented to lactic and acetic acid with the inoculant, resulting in a lower pH, less dry matter losses and protein degradation and a better aerobic stability. The effects of the additive on fermentation quality were more pronounced after 150 than after 60 d of ensiling, because the quality of the control silage was worse after long ensiling period. The treatment lowered NDF content of grass harvested at the first two growth stages by degrading cell walls to complex sugars, but had no effect on NDF degradability of the silage. The inoculant had no effect on rumen OM degradability nor on OMd after the short ensiling period, but increased the rumen OM degradability for the first two growth stages and OMd for all growth stages after long ensiling period.

  10. Quality assurance and quality control for Hydro-Quebec's ambient air monitoring networks

    International Nuclear Information System (INIS)

    Lambert, M.; Varfalvy, L.

    1993-01-01

    Hydro Quebec has three ambient air monitoring networks to determine the contribution of some of its thermal plants to ambient air quality. They are located in Becancour (gas turbines), Iles-de-la-Madeleine (diesel), and Tracy (conventional oil-fired). To ensure good quality results and consistency between networks, a quality assurance/quality control program was set up. A description is presented of the ambient air quality monitoring network and the quality assurance/quality control program. A guide has been created for use by the network operators, discussing objectives of the individual network, a complete description of each network, field operation for each model of instrument in use, treatment of data for each data logger in use, global considerations regarding quality assurance and control, and reports. A brief overview is presented of the guide's purpose and contents, focusing on the field operation section and the sulfur dioxide and nitrogen oxide monitors. 6 figs., 1 tab

  11. Performance and quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Paras, P.

    1981-01-01

    The status and the recent developments of nuclear medicine instrumentation performance, with an emphasis on gamma-camera performance, are discussed as the basis for quality control. New phantoms and techniques for the measurement of gamma-camera performance parameters are introduced and their usefulness for quality control is discussed. Tests and procedures for dose calibrator quality control are included. Also, the principles of quality control, tests, equipment and procedures for each type of instrument are reviewed, and minimum requirements for an effective quality assurance programme for nuclear medicine instrumentation are suggested. (author)

  12. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2004-01-01

    This volume treats the four main categories of Statistical Quality Control: General SQC Methodology, On-line Control including Sampling Inspection and Statistical Process Control, Off-line Control with Data Analysis and Experimental Design, and, fields related to Reliability. Experts with international reputation present their newest contributions.

  13. Proteomics Quality Control: Quality Control Software for MaxQuant Results.

    Science.gov (United States)

    Bielow, Chris; Mastrobuoni, Guido; Kempa, Stefan

    2016-03-04

    Mass spectrometry-based proteomics coupled to liquid chromatography has matured into an automatized, high-throughput technology, producing data on the scale of multiple gigabytes per instrument per day. Consequently, an automated quality control (QC) and quality analysis (QA) capable of detecting measurement bias, verifying consistency, and avoiding propagation of error is paramount for instrument operators and scientists in charge of downstream analysis. We have developed an R-based QC pipeline called Proteomics Quality Control (PTXQC) for bottom-up LC-MS data generated by the MaxQuant software pipeline. PTXQC creates a QC report containing a comprehensive and powerful set of QC metrics, augmented with automated scoring functions. The automated scores are collated to create an overview heatmap at the beginning of the report, giving valuable guidance also to nonspecialists. Our software supports a wide range of experimental designs, including stable isotope labeling by amino acids in cell culture (SILAC), tandem mass tags (TMT), and label-free data. Furthermore, we introduce new metrics to score MaxQuant's Match-between-runs (MBR) functionality by which peptide identifications can be transferred across Raw files based on accurate retention time and m/z. Last but not least, PTXQC is easy to install and use and represents the first QC software capable of processing MaxQuant result tables. PTXQC is freely available at https://github.com/cbielow/PTXQC .

  14. Analytical quality control service programme, intercomparison runs, certified reference materials, reference materials 1987-88

    International Nuclear Information System (INIS)

    1986-12-01

    The purpose of the Analytical Quality Control Services (AQCS) programme provided by the IAEA, is to assist laboratories engaged in the analysis of nuclear, environmental, biological, and materials of marine origin for radionuclide, major, minor and trace elements, as well as stable isotopes using atomic and nuclear analytical techniques, to check the quality of their work. The tables give details of the intercomparison samples and reference materials distributed by the IAEA in the period 1987 to 1988. 2 tabs

  15. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

    International Nuclear Information System (INIS)

    Létourneau, Daniel; McNiven, Andrea; Keller, Harald; Wang, An; Amin, Md Nurul; Pearce, Jim; Norrlinger, Bernhard; Jaffray, David A.

    2014-01-01

    Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods: The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves

  16. Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    Science.gov (United States)

    Létourneau, Daniel; Wang, An; Amin, Md Nurul; Pearce, Jim; McNiven, Andrea; Keller, Harald; Norrlinger, Bernhard; Jaffray, David A

    2014-12-01

    High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3-4 times/week over a period of 10-11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ± 0.5 and ± 1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. The precision of the MLC performance monitoring QC test and the MLC itself was within ± 0.22 mm for most MLC leaves and the majority of the

  17. Evaluation of 'period-generated' control laws for the time-optimal control of reactor power

    International Nuclear Information System (INIS)

    Bernard, J.A.

    1988-01-01

    Time-Optimal control of neutronic power has recently been achieved by developing control laws that determine the actuator mechanism velocity necessary to produce a specified reactor period. These laws are designated as the 'MIT-SNL Period-Generated Minimum Time Control Laws'. Relative to time-optimal response, they function by altering the rate of change of reactivity so that the instantaneous period is stepped from infinity to its minimum allowed value, held at that value until the desired power level is attained, and then stepped back to infinity. The results of a systematic evaluation of these laws are presented. The behavior of each term in the control laws is shown and the capability of these laws to control properly the reactor power is demonstrated. Factors affecting the implementation of these laws, such as the prompt neutron lifetime and the differential reactivity worth of the actuators, are discussed. Finally, the results of an experimental study in which these laws were used to adjust the power of the 5 MWt MIT Research Reactor are shown. The information presented should be of interest to those designing high performance control systems for test, spacecraft, or, in certain instances, commercial reactors

  18. Specialized software for optimization of the quality control of the mammography units

    International Nuclear Information System (INIS)

    Stoeva, M.; Vassileva, J.

    2004-01-01

    Quality control is essential to ensure the equipment used is reliable and consistent in order to maintain radiation does as low as reasonably achievable whilst optimizing image quality and performance in mammography. The effectiveness of mammographic screening is highly dependent on the consistent production of high quality diagnostic images. Mammography is highly dependent on the equipment status, which requires an effective Quality Control (QC) program to provide tools for continuous assessment of the equipment performance and also data storage and analysis of the protocols' data. The objective of this paper is to present the specialized software for Quality Control of the Mammography Units, as tool providing additional functionality for optimizations of the Mammography QC data storage and management. The PC program was developed according to the requirements stated in the European protocol for Quality Control of the Mammography Screening and the data collected as a result of its application in several Bulgarian hospitals. The Structured Analysis method was used in order to perform a case, which resulted in the development of the specialized software with a database module, providing the following functionality: Data Storage, Preliminary Data Processing and Post-Processing, Manual Data Entry, Data Import from XLS format, Data Export to XLS format, Printing, Data Filters, Automated Calculation, Automated Graphical Representation, Archiving The development of specialized QC software with a database for mammography units facilitates the process of QC data storage and handling and minimizes the errors. The electronic format for data storage is especially useful in case of long-term storage and periodical data analysis/access. The integrated data processing functionality and the automated import/export features based on standard platform increase the compatibility of the data. (authors)

  19. Effect of polyethylene glycol 6000 and storage period on seed quality of cocoa (Theobroma cacao L.

    Directory of Open Access Journals (Sweden)

    Astiti Rahayu

    2014-05-01

    Full Text Available Increased productivity of cocoa needs high quality of cocoa seeds which are generally provided by certified seed gardens located far from smallholders farm, where seed delivery takes long time and may reduce physiological quality of seeds. One effort to maintain the seed quality is by treatment the seeds with polyethylene glycol6000 (PEG 6000. This study was aimed to study the interaction of PEG 6000 concentration and storage period on cocoa seed quality, and to determine the best concentration of PEG 6000 and storage period to maintain cocoa seed quality. The research was conducted in seed storage room, seed laboratory and green houseof PPPPTK, Cianjur. The experimental design used was a factorial completely randomized design and each combination treatment repeated three times. The first factor was concentration of PEG 6000 of 0%, 20%, 40%, and 60%, and the second factor was the storage period of 3 weeks, 6 weeks, 9 weeks, and 12 weeks. The results showed that concentration of PEG 60% with three weeks storage period was able to minimize the number of moldy seeds. The concentration of PEG 20%, 40%, and 60% were able to prevent seed germination in storage until six weeks. Concentration of PEG 6000 20% was able to maintain moisture content, seed germination, and germination rate.Key words:cocoa seed, storage, recalcitrant, PEG

  20. Base for a remote quality control system for magnetic resonance images machines

    International Nuclear Information System (INIS)

    Gonzalez Dalmau, Evelio R; Cabal Mirabal, Carlos; Noda Guerra, Manuel

    2014-01-01

    The medical images systems convert characteristic of the tissues in gray levels or color, using a physical method and a specific mathematical transformation. In Magnetic Resonance Images (MRI) these levels have a multi-parametric dependence, this a reason of their strong presence in the daily clinical practice. This technological complexity, the high costs and the importance that have these study for the patient's life, confer to the Quality Control (QC) human, technological, economic and juridical implications. Several international groups dedicated to the QC in MRI and diversity of approaches to carry out the tests of acceptance and periodic control of the quality exist. The characterization is habitually carried out, with global methods that don't allow a detailed quantitative parametric study. A novel system of quantitative control was developed based on quantitative describers by slices and temporal. This system is formed for: 1) standard methodology of acquisition of the experimental data, 2) subsystem of functions and programs developed in MatLab, 3) subsystem of graphics and reports, and 4) the expert. It is used successfully in the characterization and the periodic control of MRI machines of several magnetic fields in Cuba and in Venezuela. They were defined and established quantitative descriptors for MRI machines. The software flexibility allows carry out the QC to any machine facilitating the standardization and its use in multi-center studies. The retrospective and predictive value of the system was demonstrated. They feel the bases for the remote realization of the test

  1. Quality control of image-intensifier television chains in Finland

    International Nuclear Information System (INIS)

    Pirinen, M.

    1989-01-01

    There are some 500 image-intensifier television (TV) chains connected to fluoroscopic units in Finland, most installed in the 1970s, although the oldest still in use date back to the late 1960s. To establish performance levels of the chains, 300 of them were assessed in 1982 by the Finnish Centre for Radiation and Nuclear Safety (STUK). Results showed great diversity in the condition of the chains. The main reason was lack of periodical quality assurance of the chains. Recommendations for limits were established from results of assessing three parameters describing the condition of the chains: spatial resolution, automatically controlled dose-rate and contrast sensitivity. Recommendations also advise hospitals on how to arrange alternative quality assurance measurements and observations, either by hospital's maintenance staff, the manufacturer, or the supervising authority (STUK). Results following adoption of the recommendations by hospitals are presented. (author)

  2. 7 CFR 58.733 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good quality...

  3. Descriptive study of the quality control in mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2005-01-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  4. Quality-control design for surface-water sampling in the National Water-Quality Network

    Science.gov (United States)

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  5. Quality control in dental diagnostic radiology : anomalous in the use of radiological equipment

    International Nuclear Information System (INIS)

    Alcaraz, M.; Martinez-Beneyto, Y.; Jodar, S.; Velasco, E.; Garcia-Vera, M. C.

    2004-01-01

    7,176 official quality control reports on dental diagnostic radiology were studied, relating to dental clinics located in 37 Spanish provinces covering 16 different autonomous Regions. The reports were issued as a result of the entry into force of Royal Decree 2071/1995 on quality control in General Diagnostic Radiology facilities, this Royal Decree was replaced by R. D. 1976/1999. The reports were writen by the UTPR (Technical Unit of Radiological Protection) Agsigma S. A. L., a company approved by the Nuclear Safety Council, and they correspond with the official reports issued during 1996-2001. This meants that a 5-year period has been monitored in order to observe the impacts of the establlishment of this legislation on quality control in intraoral dental diagnostic radiology facilities. The results show that 72.79% of the reports checked in 2001 would comply with the European Union's official recommendation (70 kVp, 8 mA> 1.5 mm of Al and 20 cm collimator length). Significant alterations have detected in a third (30.59%) of the radiological equipment. (Author) 36 refs

  6. Role of water quality assessments in hospital infection control: Experience from a new oncology center in eastern India

    Directory of Open Access Journals (Sweden)

    Ramkrishna Bhalchandra

    2014-01-01

    Full Text Available Water quality assessment and timely intervention are essential for health. Microbiology, total dissolved solids (TDS and free residual chlorine were measured for water quality maintenance in an oncology center in India. Impact of these interventions over a period of 22 months has been demonstrated with four cardinal events. Pseudomonas in hospital water was controlled by adequate chlorination, whereas high TDS in the central sterile supply department water was corrected by the installation of electro-deionization plant. Contaminated bottled water was replaced using quality controlled hospital supply. Timely detection and correction of water-related issues, including reverse osmosis plant was possible through multi-faceted approach to water quality.

  7. Concrete and steel construction quality control and assurance

    CERN Document Server

    El-Reedy, Mohamed A

    2014-01-01

    Starting with the receipt of materials and continuing all the way through to the final completion of the construction phase, Concrete and Steel Construction: Quality Control and Assurance examines all the quality control and assurance methods involving reinforced concrete and steel structures. This book explores the proper ways to achieve high-quality construction projects, and also provides a strong theoretical and practical background. It introduces information on quality techniques and quality management, and covers the principles of quality control. The book presents all of the quality control and assurance protocols and non-destructive test methods necessary for concrete and steel construction projects, including steel materials, welding and mixing, and testing. It covers welding terminology and procedures, and discusses welding standards and procedures during the fabrication process, as well as the welding codes. It also considers the total quality management system based on ISO 9001, and utilizes numer...

  8. COLLABORATIVE TRIAL AND QUALITY CONTROL IN CHEMICAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    Narsito Narsito

    2010-06-01

    Full Text Available Abstract                                                             This paper deals with some practical problems related to the quality of analytical chemical data usually met in practice. Special attention is given to the topic of quality control in analytical chemistry, since analytical data is one of the primary information from which some important scientifically based decision are to be made. The present paper starts with brief description on some fundamental aspects associated with quality of analytical data, such as sources of variation of analytical data, criteria for quality of analytical method, quality assurance in chemical analysis. The assessment of quality parameter for analytical method like the use of standard materials as well as standard methods is given. Concerning with the quality control of analytical data, the use of several techniques, such as control samples and control charts, in monitoring analytical data in quality control program are described qualitatively.  In the final part of this paper, some important remarks for the preparation of collaborative trials, including the evaluation of accuracy and reproducibility of analytical method are also given Keywords: collaborative trials, quality control, analytical data Abstract                                                             This paper deals with some practical problems related to the quality of analytical chemical data usually met in practice. Special attention is given to the topic of quality control in analytical chemistry, since analytical data is one of the primary information from which some important scientifically based decision are to be made. The present paper starts with brief description on some fundamental aspects associated with quality of analytical data, such as sources of variation of analytical data, criteria for quality of

  9. 42 CFR 84.40 - Quality control plans; filing requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; filing requirements. 84.40... Control § 84.40 Quality control plans; filing requirements. As a part of each application for approval or... proposed quality control plan which shall be designed to assure the quality of respiratory protection...

  10. 30 CFR 28.30 - Quality control plans; filing requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; filing requirements. 28... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed to...

  11. Quantum Control and Entanglement using Periodic Driving Fields

    International Nuclear Information System (INIS)

    Creffield, C. E.

    2007-01-01

    We propose a scheme for producing directed motion in a lattice system by applying a periodic driving potential. By controlling the dynamics by means of the effect known as coherent destruction of tunneling, we demonstrate a novel ratchetlike effect that enables particles to be coherently manipulated and steered without requiring local control. Entanglement between particles can also be controllably generated, which points to the attractive possibility of using this technique for quantum information processing

  12. External Periodic Force Control of a Single-Degree-of-Freedom Vibroimpact System

    Directory of Open Access Journals (Sweden)

    Jingyue Wang

    2013-01-01

    Full Text Available A single-degree-of-freedom mechanical model of vibro-impact system is established. Bifurcation and chaos in the system are revealed with the time history diagram, phase trajectory map, and Poincaré map. According to the bifurcation and chaos of the actual vibro-impact system, the paper puts forward external periodic force control strategy. The method of controlling chaos by external periodic force feedback controller is developed to guide chaotic motions towards regular motions. The stability of the control system is also analyzed especially by theory. By selecting appropriate feedback coefficients, the unstable periodic orbits of the original chaotic orbit can be stabilized to the stable periodic orbits. The effectiveness of this control method is verified by numerical simulation.

  13. Protein quality control in the nucleus

    DEFF Research Database (Denmark)

    Nielsen, Sofie V.; Poulsen, Esben Guldahl; Rebula, Caio A.

    2014-01-01

    to aggregate, cells have evolved several elaborate quality control systems to deal with these potentially toxic proteins. First, various molecular chaperones will seize the misfolded protein and either attempt to refold the protein or target it for degradation via the ubiquitin-proteasome system...... to be particularly active in protein quality control. Thus, specific ubiquitin-protein ligases located in the nucleus, target not only misfolded nuclear proteins, but also various misfolded cytosolic proteins which are transported to the nucleus prior to their degradation. In comparison, much less is known about...... these mechanisms in mammalian cells. Here we highlight recent advances in our understanding of nuclear protein quality control, in particular regarding substrate recognition and proteasomal degradation....

  14. 21 CFR 211.22 - Responsibilities of quality control unit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or rejecting...

  15. Assessment of long-term and large-scale even-odd license plate controlled plan effects on urban air quality and its implication

    Science.gov (United States)

    Zhao, Suping; Yu, Ye; Qin, Dahe; Yin, Daiying; He, Jianjun

    2017-12-01

    To solve traffic congestion and to improve urban air quality, long-lasting and large-scale even-odd license plate controlled plan was implemented by local government during 20 November to 26 December 2016 in urban Lanzhou, a semi-arid valley city of northwest China. The traffic control measures provided an invaluable opportunity to evaluate its effects on urban air quality in less developed cities of northwest China. Based on measured simultaneously air pollutants and meteorological parameters, the abatement of traffic-related pollutants induced by the implemented control measures such as CO, PM2.5 and PM10 (the particulate matter with diameter less than 2.5 μm and 10 μm) concentrations were firstly quantified by comparing the air quality data in urban areas with those in rural areas (uncontrolled zones). The concentrations of CO, NO2 from motor vehicles and fine particulate matter (PM2.5) were shown to have significant decreases of 15%-23% during traffic control period from those measured before control period with hourly maximum CO, PM2.5, and NO2/SO2 reduction of 43%, 35% and 141.4%, respectively. The influence of the control measures on AQI (air quality index) and ozone was less as compared to its effect on other air pollutants. Therefore, to alleviate serious winter haze pollution in China and to protect human health, the stringent long-term and large-scale even-odd license plate controlled plan should be implemented aperiodically in urban areas, especially for the periods with poor diffusion conditions.

  16. 40 CFR 81.112 - Charleston Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.112 Charleston Intrastate Air Quality Control Region. The Charleston Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... Quality Control Region: Region 1. 81.107Greenwood Intrastate Air Quality Control Region: Region 2. 81...

  17. Chicken meat quality as a function of fasting period and water spray

    OpenAIRE

    Komiyama, CM; Mendes, AA; Takahashi, SE; Moreira, J; Garcia, RG; Sanfelice, C; Borba, HS; Leonel, FR; Almeida Paz, ICL; Balog, A

    2008-01-01

    This study aimed at evaluating the effect of different fasting periods and water spray during lairage on the quality of chicken meat. A number of 300 male Ross broilers were reared up to 42 days of age, and submitted to four pre-slaughter fasting periods (4, 8, 12, and 16 hours) and sprayed with water or not during lairage. Deboned breast meat was submitted to the following analysis: pH, color, drip loss, water retention capacity, cooking loss, and shear force. There was a significant effect ...

  18. 40 CFR 81.88 - Billings Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.88 Billings Intrastate Air Quality Control Region. The Metropolitan Billings Intrastate Air Quality Control Region (Montana) has been renamed the Billings Intrastate Air Quality Control... to by Montana authorities as follows: Sec. 481.168Great Falls Intrastate Air Quality Control Region...

  19. Intra- and Intercellular Quality Control Mechanisms of Mitochondria

    Directory of Open Access Journals (Sweden)

    Yoshimitsu Kiriyama

    2017-12-01

    Full Text Available Mitochondria function to generate ATP and also play important roles in cellular homeostasis, signaling, apoptosis, autophagy, and metabolism. The loss of mitochondrial function results in cell death and various types of diseases. Therefore, quality control of mitochondria via intra- and intercellular pathways is crucial. Intracellular quality control consists of biogenesis, fusion and fission, and degradation of mitochondria in the cell, whereas intercellular quality control involves tunneling nanotubes and extracellular vesicles. In this review, we outline the current knowledge on the intra- and intercellular quality control mechanisms of mitochondria.

  20. Mechanism design of reverse auction on concession period and generalized quality for PPP projects

    Institute of Scientific and Technical Information of China (English)

    Xianjia WANG; Shiwei WU

    2017-01-01

    Reverse auctions of PPP projects usually require the bid to specify several characteristics of quality and the concession period to be fulfilled.This paper sets up a summary function of generalized quality,which contributes to reducing the dimensions of information.Thus,the multidimensional reverse auction model of a PPP project can be replaced by a two-dimensional direct mechanism based on the concession period and the generalized quality.Based on the theory of the revelation principle,the feasibility conditions,equilibrium solution and generalized quality requirements of such a mechanism,considering the influence of a variable investment structure are described.Moreover,two feasible multidimensional reverse auctions for implementing such a direct mechanism:Adjusting the scoring function and establishing a special reverse auction rule are built.The analysis shows that in these types of reverse auctions,optimal allocation can be achieved,the social benefit under the incomplete information will be maximized,and the private sector with the highest integrated management level wins the bid.In such a direct mechanism,the investment and financial pressure of the public sector can be reduced.

  1. Fuel cycle and quality control

    International Nuclear Information System (INIS)

    Stoll, W.

    1979-01-01

    The volume of the fuel cycle is described in its economic importance and its through put, as it is envisaged for the Federal Republic of Germany. Definitions are given for quality continuing usefulness of an object and translated into quality criteria. Requirements on performance of fuel elements are defined. The way in which experimental results are translated into mass production of fuel rods, is described. The economic potential for further quality effort is derived. Future ways of development for quality control organisation and structure are outlined. (Auth.)

  2. Optimal sampling period of the digital control system for the nuclear power plant steam generator water level control

    International Nuclear Information System (INIS)

    Hur, Woo Sung; Seong, Poong Hyun

    1995-01-01

    A great effort has been made to improve the nuclear plant control system by use of digital technologies and a long term schedule for the control system upgrade has been prepared with an aim to implementation in the next generation nuclear plants. In case of digital control system, it is important to decide the sampling period for analysis and design of the system, because the performance and the stability of a digital control system depend on the value of the sampling period of the digital control system. There is, however, currently no systematic method used universally for determining the sampling period of the digital control system. Generally, a traditional way to select the sampling frequency is to use 20 to 30 times the bandwidth of the analog control system which has the same system configuration and parameters as the digital one. In this paper, a new method to select the sampling period is suggested which takes into account of the performance as well as the stability of the digital control system. By use of the Irving's model steam generator, the optimal sampling period of an assumptive digital control system for steam generator level control is estimated and is actually verified in the digital control simulation system for Kori-2 nuclear power plant steam generator level control. Consequently, we conclude the optimal sampling period of the digital control system for Kori-2 nuclear power plant steam generator level control is 1 second for all power ranges. 7 figs., 3 tabs., 8 refs. (Author)

  3. Guidebook on quality control of water reactor fuel

    International Nuclear Information System (INIS)

    1983-01-01

    As a result of the increasing contribution of nuclear power to the world's supply of electrical energy, growing emphasis is being placed on the reliability of nuclear fuel performance. The need to produce a reliable product is based not only on economic reasons but also on safety considerations. Fuel assemblies must withstand the operational requirements placed on them while in the reactor; also, in some cases, they have to be stored for long periods in water-filled basins until they are either reprocessed or ultimately subjected to disposal. One of the keys to consistent and reliable fuel production is an adequate Quality Control (QC) programme, operating under a Quality Assurance (QA) system. In connection with various activities sponsored by the International Atomic Energy Agency it has been suggested for some time that a guidebook should be published, highlighting the role that QC plays in the manufacture of nuclear fuel and stressing the relationship that exists between the QC and QA functions. The aim of this book is to give a summary of the present state of practical experience in the areas of: quality-relevant design requirements; quality control of products and processes. Specific QA requirements are referred to where they are important for an understanding of the co-operation required between the various activities involved in nuclear fuel technology. Examples are also given to illustrate specific needs or specific types of experience in this area. In order to distinguish clearly between the generally required criteria and rules and the details of particular practical experience, the book is divided into two main parts. Part A focuses on the philosophy and principles; Part B supplements Part A with technically detailed descriptions and examples

  4. Asset quality in a crisis period: An empirical examination of Ghanaian banks

    Directory of Open Access Journals (Sweden)

    Abdul Latif Alhassan

    2014-01-01

    Full Text Available This paper examines the factors that account for the deterioration in the asset quality of Ghanaian banks during a period of financial crises using a unique dataset on 25 banks from 2005 to 2010. Based on system Generalized Method of Moments estimations, we find that the persistence of non-performing loans in addition to loan growth, bank market structure, bank size, inflation, real exchange rate and GDP growth are the significant determinants of banks asset quality in Ghana. The findings have implications for both bank management and regulators in emerging economies.

  5. 7 CFR 58.141 - Alternate quality control program.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by the...

  6. Quality Control Procedure Based on Partitioning of NMR Time Series

    Directory of Open Access Journals (Sweden)

    Michał Staniszewski

    2018-03-01

    Full Text Available The quality of the magnetic resonance spectroscopy (MRS depends on the stability of magnetic resonance (MR system performance and optimal hardware functioning, which ensure adequate levels of signal-to-noise ratios (SNR as well as good spectral resolution and minimal artifacts in the spectral data. MRS quality control (QC protocols and methodologies are based on phantom measurements that are repeated regularly. In this work, a signal partitioning algorithm based on a dynamic programming (DP method for QC assessment of the spectral data is described. The proposed algorithm allows detection of the change points—the abrupt variations in the time series data. The proposed QC method was tested using the simulated and real phantom data. Simulated data were randomly generated time series distorted by white noise. The real data were taken from the phantom quality control studies of the MRS scanner collected for four and a half years and analyzed by LCModel software. Along with the proposed algorithm, performance of various literature methods was evaluated for the predefined number of change points based on the error values calculated by subtracting the mean values calculated for the periods between the change-points from the original data points. The time series were checked using external software, a set of external methods and the proposed tool, and the obtained results were comparable. The application of dynamic programming in the analysis of the phantom MRS data is a novel approach to QC. The obtained results confirm that the presented change-point-detection tool can be used either for independent analysis of MRS time series (or any other or as a part of quality control.

  7. Quality control of 11C-carfentanil

    International Nuclear Information System (INIS)

    Zhang Xiaojun; Zhang Jinming; Tian Jiahe; Xiang Xiaohui

    2013-01-01

    To study the quality control of 11 C-Carfentanil injection, physical, chemical and biological identification were used. The chemical and radiochemical purity of 11 C-Carfentanil Injection were detected by HPLC and Flower Count system; measured the quantity of product by LC-MS, specific activity was calculated later; The PTS was used to detect endotoxin, and other quality control methods were put up to guarantee the security of its clinical application. The produce appeared colorless and transparent, the radiochemical purity was more than 98%, content of the endotoxin was less than 5 EU/mL. The result showed that 11 C-Carfentanil injection had fulfilled pharmaceutical quality control request and could be applied safely to animal experiment and clinical diagnosis. (authors)

  8. Hygienic quality control of chicken (thighs) by means of ionizing radiations

    International Nuclear Information System (INIS)

    Lescano, G.; Kairiyama, E.; Narvaiz, P.; Kaupert, N.L.

    1990-01-01

    High quality chicken thighs, packed in polystyrene trays covered with PVC films, were treated with ionizing energy provided by a semiindustrial 60 Co facility, with a dose of 2.5 kGy, at the temperature of melting ice. Control and irradiated samples were stored at 2 deg C ± 2 deg C and RH: 89 % ± 6 %. Microbiological, chemical and sensory evaluations were performed. This treatment improved significantly the hygienic quality of the product, and reduced in two log cycles the initial number of aerobic bacteria, which led to a 2.5 times extension of the commercialization period. A diminished water content was observed after irradiation. Decreasing values were also found in every sample as storage time went by; the irradiated sample, on day 23, had values 9 % lower than that of the control sample on day 2. Rancidity, measured as peroxide number, increased their values after irradiation, but in such extent that was not noticed organoleptically. It was never higher than 10 meg/kg of fat (specification of the Argentine Alimentary Codex for oils). The commercial quality of the irradiated samples was acceptable until day 22. (Author) [es

  9. As the thermoluminescent dosimetry can help in the quality control in radiotherapy

    International Nuclear Information System (INIS)

    Araujo, Anna Maria Campos de; Marin, Alfredo Viamonte; Viegas, Claudio C.B.; Souza, Roberto Salomon de; Alves, Victor Gabriel Leandro

    2011-01-01

    According to the international (International Atomic Energy Agency) and national (Agencia Nacional de Vigilancia Sanitaria- ANVISA) rules, the irradiators of any radiotherapy department should be periodical/y checked through a quality control external audit. In Brazil, where we have about 300 radiotherapy equipment, is very difficult to perform these audits on site with a acceptable frequency. For this reason, the Quality Service on Ionizing Radiations from the National Cancer Institute-INCA/Rio de Janeiro, developed and implemented postal systems to evaluate the main parameters of the radiotherapeutic equipment (Co-60, linear accelerators and high dose rate brachytherapy). All the postal systems developed are based on thermoluminescent dosimeters. The aim of this paper is to share the INCA experience in the use of TLD for dose evaluation and quality control measurements. Following the same philosophy, INCA developed also a postal system to evaluate the doses in mammography, since Brazil has 4000 equipment and performs about 8 millions of mammograms per year. A new experience is studying the OSL dosimeters to be used also for dose evaluation, including for in vivo dosimetry. (author)

  10. Water quality control system and water quality control method

    International Nuclear Information System (INIS)

    Itsumi, Sachio; Ichikawa, Nagayoshi; Uruma, Hiroshi; Yamada, Kazuya; Seki, Shuji

    1998-01-01

    In the water quality control system of the present invention, portions in contact with water comprise a metal material having a controlled content of iron or chromium, and the chromium content on the surface is increased than that of mother material in a state where compression stresses remain on the surface by mechanical polishing to form an uniform corrosion resistant coating film. In addition, equipments and/or pipelines to which a material controlling corrosion potential stably is applied on the surface are used. There are disposed a cleaning device made of a material less forming impurities, and detecting intrusion of impurities and removing them selectively depending on chemical species and/or a cleaning device for recovering drain from various kinds of equipment to feedwater, connecting a feedwater pipeline and a condensate pipeline and removing impurities and corrosion products. Then, water can be kept to neutral purified water, and the concentrations of oxygen and hydrogen in water are controlled within an optimum range to suppress occurrence of corrosion products. (N.H.)

  11. Stability of Closed Loop Controlled Repetitive Periodic System applied to control of CD-Player

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Stoustrup, Jakob; Andersen, Palle

    2005-01-01

    In this paper a criterion for stability of specific control scheme for handling linear dynamic control systems with repetitive periodic sensor faults is derived. The given system and control scheme are described and defined. By combining these with the lifting technique a necessary and sufficient...

  12. Report on the analysis of the quality assurance and quality control data for the petroleum refining sector

    International Nuclear Information System (INIS)

    Thorton, N.; Michajluk, S.; Powell, T.; Lee, G.

    1992-07-01

    The Ontario Municipal-Industrial Strategy for Abatement (MISA) program has the ultimate goal of virtual elimination of persistent toxic contaminants from all discharges to provincial waterways. MISA effluent monitoring regulations, first promulgated for the petroleum refining sector, require direct dischargers to monitor their effluents for a specified number of contaminants and a specified frequency over a one-year period. The refineries were also required to carry out a quality control program on all process effluent streams and for specified analytical test groups. Two types of quality assurance/quality control (QA/QC) data were required: field QA/QC, which would indicate problems with field contamination or sampling, and laboratory QA/QC, which would indicate problems with the laboratory. The objectives of QA/QC analysis are to identify the significance of biases, chronic contamination, data variability, and false results, to assess data validity, and to allow data comparability among companies and laboratories. Of the 149 parameters monitored in the petroleum refining sector, 34 qualified as candidates for setting effluent limits. The QA/QC evaluation of monitoring data for the 34 parameters confirmed the presence of 18 parameters at such levels that they could be used to set statistically valid quantitative limits. 50 tabs

  13. Internal quality control of PCR-based genotyping methods

    DEFF Research Database (Denmark)

    Bladbjerg, Else-Marie; Gram, Jørgen; Jespersen, Jørgen

    2002-01-01

    Internal quality control programmes for genetic analyses are needed. We have focused on quality control aspects of selected polymorphism analyses used in thrombosis research. DNA was isolated from EDTA-blood (n = 500) and analysed for 18 polymorphisms by polymerase chain reaction (PCR), i...... because of positive reagent blanks (controls (Control of data handling revealed 0.1% reading mistakes and 0.5% entry mistakes. Based on our experiences, we propose an internal quality control programme......, electrophoresis (analytical factors), result reading and entry into a database (post-analytical factors). Furthermore, we evaluated a procedure for result confirmation. Isolated DNA was of good quality (42 micrograms/ml blood, A260/A280 ratio > 1.75, negative DNAsis tests). Occasionally, results were reanalysed...

  14. 40 CFR 81.36 - Maricopa Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.36 Maricopa Intrastate Air Quality Control Region. The Phoenix-Tucson Intrastate Air Quality Control Region has been renamed the Maricopa Intrastate Air Quality Control Region... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Maricopa Intrastate Air Quality...

  15. Quality control and quality assurance in individual monitoring of ionising radiations

    International Nuclear Information System (INIS)

    Dutt, J.C.; Lindborg, L.

    1994-01-01

    This paper describes the programmes and approaches that are to be considered in developing and introducing quality assurance and quality control procedures in individual monitoring services. Quality assurance and quality control in individual monitoring services are essential to maintain quality and are of increasing importance in order to meet the requirements of national regulations and international standards and guidelines. It is recommended here that all organisations offering individual monitoring services should run their services based on the principles of Quality System as given in the European Standard EN45001 and maintain a property resources QA/QC programme as an integral part of their operations. All aspects of QA/QC in individual monitoring services starting from the initial selection, installation, calibration, and operation to the final products including dose reporting, dose record keeping, dealing with customers' complaints and product liability issues have been discussed. (Author)

  16. Experimental investigation of thermal comfort and air quality in an automobile cabin during the cooling period

    Energy Technology Data Exchange (ETDEWEB)

    Kilic, M.; Akyol, S.M. [Uludag University, Department of Mechanical Engineering, Faculty of Engineering and Architecture, Bursa (Turkey)

    2012-08-15

    The air quality and thermal comfort strongly influenced by the heat and mass transfer take place together in an automobile cabin. In this study, it is aimed to investigate and assess the effects of air intake settings (recirculation and fresh air) on the thermal comfort, air quality satisfaction and energy usage during the cooling period of an automobile cabin. For this purpose, measurements (temperature, air velocity, CO{sub 2}) were performed at various locations inside the cabin. Furthermore, whole body and local responses of the human subjects were noted while skin temperatures were measured. A mathematical model was arranged in order to estimate CO{sub 2} concentration and energy usage inside the vehicle cabin and verified with experimental data. It is shown that CO{sub 2} level inside of the cabin can be greater than the threshold value recommended for the driving safety if two and more occupants exist in the car. It is also shown that an advanced climate control system may satisfy the requirements for the air quality and thermal comfort as well as to reduce the energy usage for the cooling of a vehicle cabin. (orig.)

  17. Experimental investigation of thermal comfort and air quality in an automobile cabin during the cooling period

    Science.gov (United States)

    Kilic, M.; Akyol, S. M.

    2012-08-01

    The air quality and thermal comfort strongly influenced by the heat and mass transfer take place together in an automobile cabin. In this study, it is aimed to investigate and assess the effects of air intake settings (recirculation and fresh air) on the thermal comfort, air quality satisfaction and energy usage during the cooling period of an automobile cabin. For this purpose, measurements (temperature, air velocity, CO2) were performed at various locations inside the cabin. Furthermore, whole body and local responses of the human subjects were noted while skin temperatures were measured. A mathematical model was arranged in order to estimate CO2 concentration and energy usage inside the vehicle cabin and verified with experimental data. It is shown that CO2 level inside of the cabin can be greater than the threshold value recommended for the driving safety if two and more occupants exist in the car. It is also shown that an advanced climate control system may satisfy the requirements for the air quality and thermal comfort as well as to reduce the energy usage for the cooling of a vehicle cabin.

  18. Importance of cutaneous silent period in fibromyalgia and its relationship with disease characteristics, psychological disorders and quality of life of patients.

    Science.gov (United States)

    Umay, Ebru; Ulas, Umit; Unlu, Ece; Akgun, Hakan; Cakci, Aytul; Odabasi, Zeki

    2013-01-01

    Cutaneous silent period (CSP) is an inhibitory spinal protective reflex and its afferents consist of A-delta nerve fibers. We aimed to evaluate patients with fibromyalgia (FM) and healthy controls to determine any differences between the groups in terms of CSP duration and latency, and if present, to determine whether there is any relationship with disease characteristics, psychological disorders and quality of life. Thirty-two patients with FM and 32 healthy volunteers were included in the study. The patient and control groups were compared in terms of CSP latency and duration in both upper and lower extremities. Disease characteristics, psychological disorders and quality of life of patients were assessed using the Fibromyalgia Impact Questionnaire (FIQ) and Short Form-36 (SF-36). Patients with CSP measurements equal to or lower than those of the control group were compared with those with higher values than controls in terms of disease characteristics, psychological status and quality of life. Significantly prolonged CSP latencies in both upper and lower extremities were determined in patients compared to controls. We found that prolongation of CSP latency in the lower extremity is associated with disease severity and functional disability. CSP latencies in both upper and lower extremities in patients with FM are longer than in healthy volunteers. Moreover, prolongation of CSP latency in the lower extremity is associated with disease severity and physical functional disability.

  19. Quality Control - Nike.Inc

    OpenAIRE

    Walter G. Bishop

    2017-01-01

    The purpose of this paper is to present the illustration of quality control approach, which has been adopted by several organizations, in order to manage and improve their production processes. The approach is referred as total quality management (TQM). This study will discuss the implementation of TQ, within the working environment of Nike Inc. One of the major objectives behind the implementation of TQ is to reduce or completely eliminate potential errors and flaws, within the manufacturing...

  20. How to set up and manage quality control and quality assurance

    NARCIS (Netherlands)

    Visschedijk, M.; Hendriks, R.; Nuyts, K.

    2005-01-01

    This document provides a general introduction to clarify the differences between quality control (QC) and quality assurance (QA). In addition it serves as a starting point for implementing a quality system approach within an organization. The paper offers practical guidance to the implementation of

  1. 40 CFR 81.77 - Puerto Rico Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Puerto Rico Air Quality Control Region... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.77 Puerto Rico Air Quality Control Region. The Puerto Rico Air Quality Control Region...

  2. Control of stochastic resonance in bistable systems by using periodic signals

    International Nuclear Information System (INIS)

    Min, Lin; Li-Min, Fang; Yong-Jun, Zheng

    2009-01-01

    According to the characteristic structure of double wells in bistable systems, this paper analyses stochastic fluctuations in the single potential well and probability transitions between the two potential wells and proposes a method of controlling stochastic resonance by using a periodic signal. Results of theoretical analysis and numerical simulation show that the phenomenon of stochastic resonance happens when the time scales of the periodic signal and the noise-induced probability transitions between the two potential wells achieve stochastic synchronization. By adding a bistable system with a controllable periodic signal, fluctuations in the single potential well can be effectively controlled, thus affecting the probability transitions between the two potential wells. In this way, an effective control can be achieved which allows one to either enhance or realize stochastic resonance

  3. A novel Python program for implementation of quality control in the ELISA.

    Science.gov (United States)

    Wetzel, Hanna N; Cohen, Cinder; Norman, Andrew B; Webster, Rose P

    2017-09-01

    The use of semi-quantitative assays such as the enzyme-linked immunosorbent assay (ELISA) requires stringent quality control of the data. However, such quality control is often lacking in academic settings due to unavailability of software and knowledge. Therefore, our aim was to develop methods to easily implement Levey-Jennings quality control methods. For this purpose, we created a program written in Python (a programming language with an open-source license) and tested it using a training set of ELISA standard curves quantifying the Fab fragment of an anti-cocaine monoclonal antibody in mouse blood. A colorimetric ELISA was developed using a goat anti-human anti-Fab capture method. Mouse blood samples spiked with the Fab fragment were tested against a standard curve of known concentrations of Fab fragment in buffer over a period of 133days stored at 4°C to assess stability of the Fab fragment and to generate a test dataset to assess the program. All standard curves were analyzed using our program to batch process the data and to generate Levey-Jennings control charts and statistics regarding the datasets. The program was able to identify values outside of two standard deviations, and this identification of outliers was consistent with the results of a two-way ANOVA. This program is freely available, which will help laboratories implement quality control methods, thus improving reproducibility within and between labs. We report here successful testing of the program with our training set and development of a method for quantification of the Fab fragment in mouse blood. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. 21 CFR 111.105 - What must quality control personnel do?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What must quality control personnel do? 111.105..., LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must...

  5. The Study on quality control of nuclear power installation project

    International Nuclear Information System (INIS)

    Wu Jie

    2008-01-01

    The quality planning, quality assurance and quality control are discussed by applying the quality control (QC) theory and combining the real situation of the Qinshan II project. This paper is practical and plays an active role in instruction of project quality control by applying the above QC theory and control techniques. (authors)

  6. Internal control reporting and accounting quality : Insight "comply-or-explain" internal control regime

    OpenAIRE

    Cao Thi Thanh, Huyen; Cheung, Tina

    2010-01-01

    Nowadays, there exist two reporting regimes, rules-based and principle-based (comply-or-explain). In the rules-based environment, researchers have studied the relationship between internal control quality and accounting quality. Prior studies have suggested that reports on internal control are an effective way for investors to evaluate the quality of the firm‟s internal control. By having a sound system of internal control, it creates reliance upon the firm‟s financial reporting. Therefore, t...

  7. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    With the introduction of a breast screening programme in the UK, quality assurance in mammography is of paramount importance in assuring optimum imaging performance with low dose. Quality control checks are an essential part of the quality-assurance system. A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-contrast resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  8. A Total Quality-Control Plan with Right-Sized Statistical Quality-Control.

    Science.gov (United States)

    Westgard, James O

    2017-03-01

    A new Clinical Laboratory Improvement Amendments option for risk-based quality-control (QC) plans became effective in January, 2016. Called an Individualized QC Plan, this option requires the laboratory to perform a risk assessment, develop a QC plan, and implement a QC program to monitor ongoing performance of the QC plan. Difficulties in performing a risk assessment may limit validity of an Individualized QC Plan. A better alternative is to develop a Total QC Plan including a right-sized statistical QC procedure to detect medically important errors. Westgard Sigma Rules provides a simple way to select the right control rules and the right number of control measurements. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Application of environmetric methods to investigate control factors on water quality

    Directory of Open Access Journals (Sweden)

    Boyacioglu Hülya

    2017-09-01

    Full Text Available In the study, environmetric methods were successfully performed a to explore natural and anthropogenic controls on reservoir water quality, b to investigate spatial and temporal differences in quality, and c to determine quality variables discriminating three reservoirs in Izmir, Turkey. Results showed that overall water quality was mainly governed by “natural factors” in the whole region. A parameter that was the most important in contributing to water quality variation for one reservoir was not important for another. Between summer and winter periods, difference in arsenic concentrations were statistically significant in the Tahtalı, Ürkmez and iron concentrations were in the Balçova reservoirs. Observation of high/low levels in two seasons was explained by different processes as for instance, dilution from runoff at times of high flow seeped through soil and entered the river along with the rainwater run-off and adsorption. Three variables “boron, arsenic and sulphate” discriminated quality among Balçova & Tahtalı, Balçova & Ürkmez and two variables “zinc and arsenic” among the Tahtalı & Ürkmez reservoirs. The results illustrated the usefulness of multivariate statistical techniques to fingerprint pollution sources and investigate temporal/spatial variations in water quality.

  10. Quality Control of Wind Data from 50-MHz Doppler Radar Wind Profiler

    Science.gov (United States)

    Vacek, Austin

    2016-01-01

    Upper-level wind profiles obtained from a 50-MHz Doppler Radar Wind Profiler (DRWP) instrument at Kennedy Space Center are incorporated in space launch vehicle design and day-of-launch operations to assess wind effects on the vehicle during ascent. Automated and manual quality control (QC) techniques are implemented to remove spurious data in the upper-level wind profiles caused from atmospheric and non-atmospheric artifacts over the 2010-2012 period of record (POR). By adding the new quality controlled profiles with older profiles from 1997-2009, a robust database will be constructed of upper-level wind characteristics. Statistical analysis will determine the maximum, minimum, and 95th percentile of the wind components from the DRWP profiles over recent POR and compare against the older database. Additionally, this study identifies specific QC flags triggered during the QC process to understand how much data is retained and removed from the profiles.

  11. Control of quality in mammography

    International Nuclear Information System (INIS)

    2006-10-01

    The present protocol of quality control/quality assurance in mammography is the result of the work of two regional projects realised in Latin America within the frame of ARCAL with the support of the IAEA. The first is ARCAL LV (RLA/6/043) project on quality assurance/quality control in mammography studies which analysed the present situation of the mammography in the member countries of the project which include: Bolivia, Colombia, Costa Rica, Cuba, El Salvador, Guatemala, Nicaragua, Panama, Paraguay, Peru, Dominican Republic and Republic of Venezuela and the second is ARCAL XLIX (RLA/9/035) project, whose members were Brazil, Colombia, Cuba, Chile, Mexico, and Peru, worked the application of Basic Safety Standards for the protection against ionising radiation with the aim to improve radiation protection in X-ray diagnosis medical practices through the implementation of the Basic Safety Standards (BSS) related to x-ray diagnosis in selected hospitals located in each country involved in the project. The work of both projects had been consolidated and harmonized in the present publication

  12. The study on quality control of bedside CR examination

    International Nuclear Information System (INIS)

    Yang Xufeng; Luo Xiaomei; Xu Qiaolan; Wu Tengfang; Wen Xingwei

    2007-01-01

    Objective: To study the quality controll of bedside CR examination and improves the imaging quality. Methods: X-ray examination with CR system were performed on 3,300 patients. All CR cassettes were encoded. The imaging plate and cassettes were cleaned regularly. Results: With and without quality control, the percentage of first-rate film was 58.2% and 51%, the second-rate film was 40% and 45.5%, the third-rate film was 1.3% and 2%, respectively. Corxespondingly, the ratio of re-examination decreased from 1.5% to 0.5% after quality control, and imaging quality was stable. Conclusion: The quality control of bedside CR examination can improve the image quality as well as lighten the labor of radiographers. (authors)

  13. Quality assurance/quality control, reliability and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Kueffer, K.

    1981-01-01

    In a first part this lectures will present a survey on nuclear power production and plant performance in the Western World and discuss key parameters such as load factors and non-availability. Some main reasons for reliable performance of nuclear power plants are given. The second part of this lecture deals with the question how quality assurance and quality control measures do directly influence plant reliability, availability and, thus, economy. Derived from worldwide experience gained from operating nuclear power plants, it may be concluded that the implementation of an overall quality assurance programme does not only satisfy safety requirements set forth by the nuclear regulatory bodies, but has also a considerable impact on plant reliability and availability. A positive effect on these figures will be achieved if the established quality assurance programme provides for a coordinated approach to all activities affecting quality. It is discussed how the quality of a product should be controlled and what kind of quality assurance measures by performed examples are given to demonstrate that the expenditure for maintenance work on components will decrease if planned and systematic quality assurance actions have been implemented during all procurement stages. (orig./RW)

  14. 40 CFR 81.51 - Portland Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.51 Portland Interstate Air Quality Control Region. The Portland Interstate Air Quality Control Region (Oregon-Washington) has been revised to consist of the territorial area... Portland Interstate Air Quality Control Region (Oregon-Washington) will be referred to by Washington...

  15. Use of statistic control of the process as part of a quality assurance plan

    International Nuclear Information System (INIS)

    Acosta, S.; Lewis, C.

    2013-01-01

    One of the technical requirements of the standard IRAM ISO 17025 for the accreditation of testing laboratories, is the assurance of the quality of the results through the control and monitoring of the factors influencing the reliability of them. The grade the factors contribute to the total measurement uncertainty, determines which of them should be considered when developing a quality assurance plan. The laboratory of environmental measurements of strontium-90 in the accreditation process, performs most of its determinations in samples with values close to the detection limit. For this reason the correct characterization of the white, is a critical parameter and is verified through a letter for statistical process control. The scope of the present work is concerned the control of whites and so it was collected a statistically significant amount of data, for a period of time that is covered of different conditions. This allowed consider significant variables in the process, such as temperature and humidity, and build a graph of white control, which forms the basis of a statistical process control. The data obtained were lower and upper limits for the preparation of the charter white control. In this way the process of characterization of white was considered to operate under statistical control and concludes that it can be used as part of a plan of insurance of the quality

  16. Enhancing the Frequency Adaptability of Periodic Current Controllers with a Fixed Sampling Rate for Grid-Connected Power Converters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2016-01-01

    Grid-connected power converters should employ advanced current controllers, e.g., Proportional Resonant (PR) and Repetitive Controllers (RC), in order to produce high-quality feed-in currents that are required to be synchronized with the grid. The synchronization is actually to detect...... of the resonant controllers and by approximating the fractional delay using a Lagrange interpolating polynomial for the RC, respectively, the frequency-variation-immunity of these periodic current controllers with a fixed sampling rate is improved. Experiments on a single-phase grid-connected system are presented...... the instantaneous grid information (e.g., frequency and phase of the grid voltage) for the current control, which is commonly performed by a Phase-Locked-Loop (PLL) system. Hence, harmonics and deviations in the estimated frequency by the PLL could lead to current tracking performance degradation, especially...

  17. Quality assurance in education: The role of ICT and quality control ...

    African Journals Online (AJOL)

    Quality assurance in education is perceived in this paper to be a product of the impact of information and communication technologies as well as the statutory control measures especially in tertiary institutions in Nigeria. The paper reviews the concept of quality and quality assurance and their general application to ...

  18. Quality control of scintillation cameras (planar and SPECT)

    International Nuclear Information System (INIS)

    Shaekhoon, E.S.

    2008-01-01

    Regular quality control is one of the corner stones of nuclear medicine and a prerequisite for adequate diagnostic imaging. Many papers have been published on quality control of planar and SPECT imaging system up to now, however only minor attenuation has been given to the assessment of the performance of imaging systems. In this research we are going to discuss a comprehensive set of test procedures including regular quality control. Our purpose is to go through analysis of the methods and results then to test our hypothesis which state that there is strong relationship between regular and proper evaluation of quality control and the continuity of better medical services in nuclear medicine department. The selection of the tests is discussed and the tests are described, then results are presented. In addition action thresholds are proposed. The quality control tests can be applied to systems with either a moving detector or a moving image table, and to both detector with a large field of view and detectors with a small field of view. The tests presented on this research do not required special phantoms or sources other than those used for quality control of stationary gamma camera and SPECT. They can be applied for acceptance testing and for performance testing in a regular quality assurance program. The data has been evaluated based on me diso software in comparing with IAEA expert software and system specification within the reference values. Our final results confirm our hypothesis, there are some comments about the characteristics and performance of this system that being observed and solved, then a departmental protocol for routine quality control (Q.C) has being established.(Author)

  19. PACS quality control and automatic problem notifier

    Science.gov (United States)

    Honeyman-Buck, Janice C.; Jones, Douglas; Frost, Meryll M.; Staab, Edward V.

    1997-05-01

    One side effect of installing a clinical PACS Is that users become dependent upon the technology and in some cases it can be very difficult to revert back to a film based system if components fail. The nature of system failures range from slow deterioration of function as seen in the loss of monitor luminance through sudden catastrophic loss of the entire PACS networks. This paper describes the quality control procedures in place at the University of Florida and the automatic notification system that alerts PACS personnel when a failure has happened or is anticipated. The goal is to recover from a failure with a minimum of downtime and no data loss. Routine quality control is practiced on all aspects of PACS, from acquisition, through network routing, through display, and including archiving. Whenever possible, the system components perform self and between platform checks for active processes, file system status, errors in log files, and system uptime. When an error is detected or a exception occurs, an automatic page is sent to a pager with a diagnostic code. Documentation on each code, trouble shooting procedures, and repairs are kept on an intranet server accessible only to people involved in maintaining the PACS. In addition to the automatic paging system for error conditions, acquisition is assured by an automatic fax report sent on a daily basis to all technologists acquiring PACS images to be used as a cross check that all studies are archived prior to being removed from the acquisition systems. Daily quality control is preformed to assure that studies can be moved from each acquisition and contrast adjustment. The results of selected quality control reports will be presented. The intranet documentation server will be described with the automatic pager system. Monitor quality control reports will be described and the cost of quality control will be quantified. As PACS is accepted as a clinical tool, the same standards of quality control must be established

  20. Daily quality controls analysis of a CT scanner simulator

    International Nuclear Information System (INIS)

    Vasques, Maira Milanelo; Santos, Gabriela R.; Furnari, Laura

    2016-01-01

    With the increasing technological developments, radiotherapy practices, which allow for better involvement of the tumor with the required therapeutic dose and minimize the complications of normal tissues, have become reality in several Radiotherapy services. The use of these resources in turn, was only possible due to the progress made in planning based on digital volumetric images of good quality, such as computed tomography (CT), which allow the correct delimitation of the tumor volume and critical structures. Specific tests for quality control in a CT scanner used in radiotherapy, named CT simulator, should be applied as part of the institutional Quality Assurance Program. This study presents the methodology used in the Instituto de Radiologia do Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo (HCFMUSP) for daily testing of the CT scanner simulator and the results obtained throughout more than two years. The experience gained in the period conducted showed that the tests are easy to perform and can be done in a few minutes by a trained professional. Data analysis showed good reproducibility, which allowed the tests could be performed less frequently, after 16 months of data collection. (author)

  1. Quality assurance and statistical control

    DEFF Research Database (Denmark)

    Heydorn, K.

    1991-01-01

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves...... to detect analytical errors by comparing the a priori precision of the analytical results with the actual variability observed among replicates or duplicates. The method relies on the chi-square distribution to detect excess variability and is quite sensitive even for 5-10 results. Interference control...... serves to detect analytical bias by comparing results obtained by two different analytical methods, each relying on a different detection principle and therefore exhibiting different influence from matrix elements; only 5-10 sets of results are required to establish whether a regression line passes...

  2. Dynamics modeling and periodic control of horizontal-axis wind turbines

    Science.gov (United States)

    Stol, Karl Alexander

    2001-07-01

    The development of large multi-megawatt wind turbines has increased the need for active feedback control to meet multiple performance objectives. Power regulation is still of prime concern but there is an increasing interest in mitigating loads for these very large, dynamically soft and highly integrated power systems. This work explores the opportunities for utilizing state space modeling, modal analysis, and multi-objective controllers in advanced horizontal-axis wind turbines. A linear state-space representation of a generic, multiple degree-of-freedom wind turbine is developed to test various control methods and paradigms. The structural model, SymDyn, provides for limited flexibility in the tower, drive train and blades assuming a rigid component architecture with joint springs and dampers. Equations of motion are derived symbolically, verified by numerical simulation, and implemented in the Matlab with Simulink computational environment. AeroDyn, an industry-standard aerodynamics package for wind turbines, provides the aerodynamic load data through interfaced subroutines. Linearization of the structural model produces state equations with periodic coefficients due to the interaction of rotating and non-rotating components. Floquet theory is used to extract the necessary modal properties and several parametric studies identify the damping levels and dominant dynamic coupling influences. Two separate issues of control design are investigated: full-state feedback and state estimation. Periodic gains are developed using time-varying LQR techniques and many different time-invariant control designs are constructed, including a classical PID controller. Disturbance accommodating control (DAC) allows the estimation of wind speed for minimization of the disturbance effects on the system. Controllers are tested in simulation for multiple objectives using measurement of rotor position and rotor speed only and actuation of independent blade pitch. It is found that

  3. Quality by control: Towards model predictive control of mammalian cell culture bioprocesses.

    Science.gov (United States)

    Sommeregger, Wolfgang; Sissolak, Bernhard; Kandra, Kulwant; von Stosch, Moritz; Mayer, Martin; Striedner, Gerald

    2017-07-01

    The industrial production of complex biopharmaceuticals using recombinant mammalian cell lines is still mainly built on a quality by testing approach, which is represented by fixed process conditions and extensive testing of the end-product. In 2004 the FDA launched the process analytical technology initiative, aiming to guide the industry towards advanced process monitoring and better understanding of how critical process parameters affect the critical quality attributes. Implementation of process analytical technology into the bio-production process enables moving from the quality by testing to a more flexible quality by design approach. The application of advanced sensor systems in combination with mathematical modelling techniques offers enhanced process understanding, allows on-line prediction of critical quality attributes and subsequently real-time product quality control. In this review opportunities and unsolved issues on the road to a successful quality by design and dynamic control implementation are discussed. A major focus is directed on the preconditions for the application of model predictive control for mammalian cell culture bioprocesses. Design of experiments providing information about the process dynamics upon parameter change, dynamic process models, on-line process state predictions and powerful software environments seem to be a prerequisite for quality by control realization. © 2017 The Authors. Biotechnology Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. A generation proposal of management signals from the distribution technical service quality control; Una propuesta de generacion de senales de gestion a partir del control de calidad del servicio tecnico de distribucion

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, Pedro [Energia San Juan S.A. (Argentina). E-mail: pfpvidal@hotmail.com; Andreoni, Alberto M. [ASINELSA S.A., San Juan (Argentina). E-mail: info@asinelsa.com.ar

    1998-07-01

    A set of management signals are presented which help to make the best decision of Operation and Maintenance actions (O and M) and/or investments within the period of technical service quality control so that, at the end of it, the total cost, included compensations to customers related to energy received with bad quality technical service, can be minimized. First, the normative in force is put forward for the measurement and quality control of the technical service according to the Concession Agreement of the distribution service of electric system of San Juan Province - Argentina managed by Energia San Juan S.A. and later, a calculation methodology for some of the signals used during the management period are introduced. These signals are the result of the analysis of interruptions and relations between indicators of the same utility resulting from the first three management periods of the electric distribution system of the province. (author)

  5. Proposed quality control protocol of a dual energy bone densitometer from Spanish protocol for quality control of radiology

    International Nuclear Information System (INIS)

    Saez, F.; Benito, M. A.; Collado, P.; Saez, M.

    2011-01-01

    In this paper we propose additional testing to complete the tests by the Spanish Protocol for Quality Control of Diagnostic Radiology, taking into account the particular characteristics of these units, and including these tests in the estimation of patient dose dose assessment area. There is also the possibility to independently verify the quality control tests that are done automatically.

  6. Diffraction-Induced Bidimensional Talbot Self-Imaging with Full Independent Period Control

    Science.gov (United States)

    Guillet de Chatellus, Hugues; Romero Cortés, Luis; Deville, Antonin; Seghilani, Mohamed; Azaña, José

    2017-03-01

    We predict, formulate, and observe experimentally a generalized version of the Talbot effect that allows one to create diffraction-induced self-images of a periodic two-dimensional (2D) waveform with arbitrary control of the image spatial periods. Through the proposed scheme, the periods of the output self-image are multiples of the input ones by any desired integer or fractional factor, and they can be controlled independently across each of the two wave dimensions. The concept involves conditioning the phase profile of the input periodic wave before free-space diffraction. The wave energy is fundamentally preserved through the self-imaging process, enabling, for instance, the possibility of the passive amplification of the periodic patterns in the wave by a purely diffractive effect, without the use of any active gain.

  7. Analytical approaches to quality assurance and quality control in rangeland monitoring data

    Science.gov (United States)

    Producing quality data to support land management decisions is the goal of every rangeland monitoring program. However, the results of quality assurance (QA) and quality control (QC) efforts to improve data quality are rarely reported. The purpose of QA and QC is to prevent and describe non-sampling...

  8. AUTOMATION OF THE SYSTEM OF INTERNAL LABORATORY QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    V. Z. Stetsyuk

    2015-05-01

    Full Text Available Quality control system base d on the principles of standardi zation of all phases of laboratory testing and analysis of internal laboratory quality control and external quality assessment. For the detection accuracy of the results of laboratory tests, carried out internally between the laboratory and laboratory quality control. Under internal laboratory quality control we understand measurement results of each analysis in each anal ytical series rendered directly in the lab every day. The purpose of internal laboratory control - identifying and eliminating unacceptable deviations from standard perfor mance test in the laboratory, i.e. identifying and eliminating harmful analytical errors. The solutions to these problems by implementing automated systems - software that allows you to optimize analytical laboratory research stage of the procedure by automatically creating process control charts was shown.

  9. 14 CFR 21.147 - Changes in quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality control...

  10. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations...

  11. Metrology and quality control handbook

    International Nuclear Information System (INIS)

    Hofmann, D.

    1983-01-01

    This book tries to present the fundamentals of metrology and quality control in brief surveys. Compromises had to be made in order to reduce the material available to a sensible volume for the sake of clarity. This becomes evident by the following two restrictions which had to made: First, in dealing with the theoretical principles of metrology and quality control, mere reference had to be made in many cases to the great variety of special literature without discussing it to explain further details. Second, in dealing with the application of metrology and quality control techniques in practice, only the basic qantities of the International System of Units (SI) could be taken into account as a rule. Some readers will note that many special measuring methods and equipment known to them are not included in this book. I do hope, however, that this short-coming will show to have a positive effect, too. This book will show the reader how to find the basic quantities and units from the derived quantities and units, and the steps that are necessary to solve any kind of measuring task. (orig./RW) [de

  12. MRI quality control: six imagers studied using eleven unified image quality parameters

    International Nuclear Information System (INIS)

    Ihalainen, T.; Sipilae, O.; Savolainen, S.

    2004-01-01

    Quality control of the magnetic resonance imagers of different vendors in the clinical environment is non-harmonised, and comparing the performance is difficult. The purpose of this study was to develop and apply a harmonised long-term quality control protocol for the six imagers in our organisation in order to assure that they fulfil the same basic image quality requirements. The same Eurospin phantom set and identical imaging parameters were used with each imager. Values of 11 comparable parameters describing the image quality were measured. Automatic image analysis software was developed to objectively analyse the images. The results proved that the imagers were operating at a performance level adequate for clinical imaging. Some deficiencies were detected in image uniformity and geometry. The automated analysis of the Eurospin phantom images was successful. The measurements were successfully repeated after 2 weeks on one imager and after half a year on all imagers. As an objective way of examining the image quality, this kind of comparable and objective quality control of different imagers is considered as an essential step towards harmonisation of the clinical MRI studies through a large hospital organisation. (orig.)

  13. European quality assurance and quality control for cut-off walls and caps

    International Nuclear Information System (INIS)

    Jefferis, S.A.

    1997-01-01

    Cut-off walls and caps both may be seriously compromised by small areas of substandard materials or work. Quality assurance/quality control is therefore of crucial importance and the paper sets out the issues that need to be addressed when designing a quality plan for a containment. Consideration is given to the purpose of the containment, the parameters to be controlled, specifications and standards and tests on raw and manufactured materials and on the in-situ containment. It is not the purpose of the paper to give detailed test procedures but rather to identify the questions that must be answered to develop a quality plan

  14. Computer-supported quality control in X-ray diagnosis

    International Nuclear Information System (INIS)

    Maier, W.; Klotz, E.

    1989-01-01

    Quality control of X-ray facilities in radiological departments of large hospitals is possible only if the instrumentation used for measurements is interfaced to a computer. The central computer helps to organize the measurements as well as analyse and record the results. It can also be connected to a densitometer and camera for evaluating radiographs of test devices. Other quality control tests are supported by a mobile station with equipment for non-invasive dosimetry measurements. Experience with a computer-supported system in quality control of film and film processing is described and the evaluation methods of ANSI and the German industrial standard DIN are compared. The disadvantage of these methods is the exclusion of film quality parameters, which can make processing control almost worthless. (author)

  15. Quality control of radiation therapy in clinical trials

    International Nuclear Information System (INIS)

    Kramer, S.; Lustig, R.; Grundy, G.

    1983-01-01

    The RTOG is a group of participating institutions which has a major interest in furthering clinical radiation oncology. They have formulated protocols for clinical investigation in which radiation therapy is the major modality of treatment. In addition, other modalities, such as chemotherapy, radiation sensitizers, and hyperthermia, are used in combined approach to cancer. Quality control in all aspects of patient management is necessary to insure quality data. These areas include evaluation of pathology, physics, and dosimetry, and clinical patient data. Quality control is both time consuming and expensive. However, by dividing these tasks into various levels and time frames, by using computerized data-control mechanisms, and by employing appropriate levels of ancillary personnel expertise, quality control can improve compliance and decrease the cost of investigational trials

  16. Secondary Control for Voltage Quality Enhancement in Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos

    2012-01-01

    In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each of these con......In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each...

  17. Influence of growing altitude, shade and harvest period on quality and biochemical composition of Ethiopian specialty coffee.

    Science.gov (United States)

    Tolessa, Kassaye; D'heer, Jolien; Duchateau, Luc; Boeckx, Pascal

    2017-07-01

    Coffee quality is a key characteristic for the international market, comprising cup quality and chemical bean constituents. In Ethiopia, using total specialty cup scores, coffees are grouped into Q1 (specialty 1) ≥ 85 and Q2 (80-84.75). This classification results in market segmentation and higher prices. Although different studies have evaluated the effects of altitude and shade on bean quality, optimum shade levels along different altitudinal ranges are not clearly indicated. Information on effects of harvest periods on coffee quality is also scanty. The present study examined the influences of these factors and their interactions on Ethiopian coffee quality RESULTS: Coffee from high altitude with open or medium shade and early to middle harvest periods had a superior bean quality. These growing conditions also favoured the production of beans with lower caffeine. An increasing altitude, from mid to high, at approximately 400 m, decreased caffeine content by 10%. At high altitude, dense shade decreased Q1 coffee by 50%. Compared to late harvesting, early harvesting increased the percentage from 27% to 73%. At mid altitude, > 80% is Q2 coffee. Changes of quality scores driven by altitude, shade and harvest period are small, although they may induce dramatic switches in the fraction Q1 versus Q2 coffee. The latter affects both farmers' profits and competitiveness in international markets. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  18. [Quality control at the Istituto di Anatomia e Istologia patologica at the Università di Bologna].

    Science.gov (United States)

    Alampi, G; Baroni, R; Berti, E; Ceccarelli, C; Dina, R; Eusebi, V; Giangaspero, F; Grigioni, F W; Lecce, S; Losi, L

    1994-04-01

    The growing importance in medical practice of a standardized diagnosis in cyto- and histopathology and the recent recommendations for the adoption of standardized schemes for quality control in anatomic pathology by International Committees stimulated the medical staff of the Institute of Anatomic Pathology of the University of Bologna to adopt a pertinent method. The method used by the Department of Pathology of the Yale University (New Haven, Connecticut, USA) was chosen. A Committee for the quality control was appointed and two kinds of controls were set up: an External Quality Assessment (review of the difficult cases by external experts, slide seminars) and an Internal Quality Assessment performed by the members of the Committee on the diagnostic and laboratory routine of the Institute. Such a survey is periodically monitored during the monthly meetings of the Committee and described in the monthly reports. The present paper illustrates the method adopted and the preliminary results obtained in order to stimulate the discussion of such a critical theme in contemporary Anatomic Pathology at a national level.

  19. Shipping/Receiving and Quality Control

    Data.gov (United States)

    Federal Laboratory Consortium — Shipping receiving, quality control, large and precise inspection and CMM machines. Coordinate Measuring Machines, including "scanning" probes, optical comparators,...

  20. High Quality Model Predictive Control for Single Phase Grid Connected Photovoltaic Inverters

    DEFF Research Database (Denmark)

    Zangeneh Bighash, Esmaeil; Sadeghzadeh, Seyed Mohammad; Ebrahimzadeh, Esmaeil

    2018-01-01

    Single phase grid-connected inverters with LCL filter are widely used to connect the photovoltaic systems to the utility grid. Among the presented control schemes, predictive control methods are faster and more accurate but are more complex to implement. Recently, the model-predictive control...... algorithm for single-phase inverter has been presented, where the algorithm implementation is straightforward. In the proposed approach, all switching states are tested in each switching period to achieve the control objectives. However, since the number of the switching states in single-phase inverter...... is low, the inverter output current has a high total harmonic distortions. In order to reduce the total harmonic distortions of the injected current, this paper presents a high-quality model-predictive control for one of the newest structure of the grid connected photovoltaic inverter, i.e., HERIC...

  1. Quality assurance programme and quality control

    International Nuclear Information System (INIS)

    Alvarez de Buergo, L.

    1979-01-01

    The paper analyses the requirements for the quality assurance and control in nuclear power plant projects which are needed to achieve safe, reliable and economic plants. The author describes the structure for the establishment of a nuclear programme at the national level and the participation of the different bodies involved in a nuclear power plant project. The paper ends with the study of a specific case in Spain. (NEA) [fr

  2. Quality control of imaging devices

    International Nuclear Information System (INIS)

    Soni, P.S.

    1992-01-01

    Quality assurance in nuclear medicine refers collectively to all aspects of a nuclear medicine service. It would include patient scheduling, radiopharmaceutical preparation and dispensing, radiation protection of patients, staff and general public, preventive maintenance and the care of instruments, methodology, data interpretation and records keeping, and many other small things which contribute directly or indirectly to the overall quality of a nuclear medicine service in a hospital. Quality Control, on the other hand, refers to a signal component of the system and is usually applied in relation to a specific instrument and its performance

  3. A comparative study of quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Kharita, M. H.; Khedr, M.S.; Wannus, K.M.

    2008-01-01

    The main objective of this comparative study was to evaluate the national quality assurance program for X-ray diagnostic radiology in Syrian governmental hospitals. Two periods were covered in this study, the first period was from 1986 to 1998 (52 hospitals and 149 X-ray machines were considered) and the second period from 1999 to 2005 (41 hospitals and 95 X-ray machines were considered). Most of the X-ray machines studied were within the acceptable performance, but few machines needed recalibration for some parameters. Considerable improvement of about 50% was reported in the second period. This improvement could be attributed to the establishment of an effective National Regulatory Authority in Syria in 1998 that introduced and gradually enforced the quality assurance requirement for X-ray equipment as part of the licensing process and to the relatively newer X-ray machines covered in the second period. The Author 2008. Published by Oxford Univ. Press. All rights reserved. (authors)

  4. 7 CFR 58.523 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  5. 21 CFR 640.56 - Quality control test for potency.

    Science.gov (United States)

    2010-04-01

    ... quality control test for potency may be performed by a clinical laboratory which meets the standards of... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control...

  6. Web quality control for lectures: Supercourse and Amazon.com.

    Science.gov (United States)

    Linkov, Faina; LaPorte, Ronald; Lovalekar, Mita; Dodani, Sunita

    2005-12-01

    Peer review has been at the corner stone of quality control of the biomedical journals in the past 300 years. With the emergency of the Internet, new models of quality control and peer review are emerging. However, such models are poorly investigated. We would argue that the popular system of quality control used in Amazon.com offers a way to ensure continuous quality improvement in the area of research communications on the Internet. Such system is providing an interesting alternative to the traditional peer review approaches used in the biomedical journals and challenges the traditional paradigms of scientific publishing. This idea is being explored in the context of Supercourse, a library of 2,350 prevention lectures, shared for free by faculty members from over 150 countries. Supercourse is successfully utilizing quality control approaches that are similar to Amazon.com model. Clearly, the existing approaches and emerging alternatives for quality control in scientific communications needs to be assessed scientifically. Rapid explosion of internet technologies could be leveraged to produce better, more cost effective systems for quality control in the biomedical publications and across all sciences.

  7. 40 CFR 81.111 - Georgetown Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.111 Georgetown Intrastate Air Quality Control Region. The Georgetown Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Georgetown Intrastate Air Quality...

  8. 40 CFR 81.107 - Greenwood Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.107 Greenwood Intrastate Air Quality Control Region. The Greenwood Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Greenwood Intrastate Air Quality...

  9. 40 CFR 81.108 - Columbia Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.108 Columbia Intrastate Air Quality Control Region. The Columbia Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Columbia Intrastate Air Quality...

  10. 40 CFR 81.109 - Florence Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.109 Florence Intrastate Air Quality Control Region. The Florence Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Florence Intrastate Air Quality...

  11. 40 CFR 81.35 - Louisville Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.35 Louisville Interstate Air Quality Control Region. The Louisville Interstate Air Quality Control Region (Kentucky-Indiana) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Louisville Interstate Air Quality...

  12. Impact of Soil Conservation Measures on Erosion Control and Soil Quality

    International Nuclear Information System (INIS)

    2011-10-01

    This publication summarises the lessons learnt from a FAO/IAEA coordinated research project on the impact of soil conservation measures on erosion control and soil quality over a five-year period across a wide geographic area and range of environments. It demonstrates the new trends in the use of fallout radionuclide-based techniques as powerful tools to assess the effectiveness of soil conservation measures. As a comprehensive reference material it will support IAEA Member States in the use of these techniques to identify practices that can enhance sustainable agriculture and minimize land degradation.

  13. [Pharmaceutical product quality control and good manufacturing practices].

    Science.gov (United States)

    Hiyama, Yukio

    2010-01-01

    This report describes the roles of Good Manufacturing Practices (GMP) in pharmaceutical product quality control. There are three keys to pharmaceutical product quality control. They are specifications, thorough product characterization during development, and adherence to GMP as the ICH Q6A guideline on specifications provides the most important principles in its background section. Impacts of the revised Pharmaceutical Affairs Law (rPAL) which became effective in 2005 on product quality control are discussed. Progress of ICH discussion for Pharmaceutical Development (Q8), Quality Risk Management (Q9) and Pharmaceutical Quality System (Q10) are reviewed. In order to reconstruct GMP guidelines and GMP inspection system in the regulatory agencies under the new paradigm by rPAL and the ICH, a series of Health Science studies were conducted. For GMP guidelines, product GMP guideline, technology transfer guideline, laboratory control guideline and change control system guideline were written. For the GMP inspection system, inspection check list, inspection memo and inspection scenario were proposed also by the Health Science study groups. Because pharmaceutical products and their raw materials are manufactured and distributed internationally, collaborations with other national authorities are highly desired. In order to enhance the international collaborations, consistent establishment of GMP inspection quality system throughout Japan will be essential.

  14. Family Control and Earnings Quality

    Directory of Open Access Journals (Sweden)

    Carolina Bona Sánchez

    2007-06-01

    Full Text Available El trabajo analiza la relación entre el control familiar y la calidad de la información contable en un contexto en el que el tradicional conflicto de agencia entre directivos y accionistas se desplaza a la divergencia de intereses entre accionistas controladores y minoritarios. Los resultados alcanzados muestran que, en comparación con las no familiares, las empresas de naturaleza familiar divulgan unos resultados de mayor calidad, tanto en términos de menores ajustes por devengo discrecionales como de mayor capacidad de los componentes actuales del resultado para predecir los cash flows futuros. Además, el aumento en los derechos de voto en manos de la familia controladora incrementa la calidad de los resultados contables. La evidencia obtenida se muestra consistente con la presencia de un efecto reputación/vinculación a largo plazo asociado a la empresa familiar. Adicionalmente, el trabajo refleja que a medida que disminuye la divergencia entre los derechos de voto y de cash flow en manos de la familia controladora, aumenta la calidad de la información contable.PALABRAS CLAVE: derechos de voto, divergencia, empresa familiar, calidad delresultado, reputación, beneficios privados.This work examines the relationship between family control and earnings quality in a context where the salient agency problem shifts away from the classical divergence between managers and shareholders to conflicts between the controlling owner and minority shareholders. The results reveal that, compared to non-family firms, family firms reveal higher earnings quality in terms of both lower discretionary accruals and greater predictability of future cash flows. They also show a positive relationship between the level of voting rights held by the controlling family and earnings quality. The evidence is consistent with the presence of a reputation/long-term involvement effect associated with the family firm. Moreover, the work reflects that, as the divergence

  15. 40 CFR 81.42 - Chattanooga Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.42 Chattanooga Interstate Air Quality Control Region. The Chattanooga Interstate Air Quality Control Region (Georgia-Tennessee) has been revised to consist of the territorial area... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Chattanooga Interstate Air Quality...

  16. Quality control and analysis of radiotracer compounds

    International Nuclear Information System (INIS)

    Sheppard, G.; Thomson, R.

    1977-01-01

    Special emphasis was on the problems and errors possible in quality control and analysis. The principles underlying quality control were outlined, and analytical techniques applicable to radiotracers were described. Chapter concluded with a selection of examples showing the effects of impurities on the use of radiotracers. The subject of quality control and analysis was treated from the viewpoint of the user and those research workers who need to synthesize and analyze their own radiochemicals. The quality characteristics for radiotracers are of two kinds, valuable or attributive. These were discussed in the chapter. For counting low radioactive concentration, scintillation techniques are in general use, whereas ionization techniques are now used mainly for the measurement of high radioactive concentrations or large quantities of radioactivity, for scanning chromatograms, and a number of very specific purposes. Determination of radionuclidic purity was discussed. Use of radiotracers in pharmaceuticals were presented. 4 figures, 6 tables

  17. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2001-01-01

    The book is a collection of papers presented at the 5th International Workshop on Intelligent Statistical Quality Control in Würzburg, Germany. Contributions deal with methodology and successful industrial applications. They can be grouped in four catagories: Sampling Inspection, Statistical Process Control, Data Analysis and Process Capability Studies and Experimental Design.

  18. A cluster-randomised quality improvement study to improve two inpatient stroke quality indicators.

    Science.gov (United States)

    Williams, Linda; Daggett, Virginia; Slaven, James E; Yu, Zhangsheng; Sager, Danielle; Myers, Jennifer; Plue, Laurie; Woodward-Hagg, Heather; Damush, Teresa M

    2016-04-01

    Quality indicator collection and feedback improves stroke care. We sought to determine whether quality improvement training plus indicator feedback was more effective than indicator feedback alone in improving inpatient stroke indicators. We conducted a cluster-randomised quality improvement trial, randomising hospitals to quality improvement training plus indicator feedback versus indicator feedback alone to improve deep vein thrombosis (DVT) prophylaxis and dysphagia screening. Intervention sites received collaborative-based quality improvement training, external facilitation and indicator feedback. Control sites received only indicator feedback. We compared indicators pre-implementation (pre-I) to active implementation (active-I) and post-implementation (post-I) periods. We constructed mixed-effect logistic models of the two indicators with a random intercept for hospital effect, adjusting for patient, time, intervention and hospital variables. Patients at intervention sites (1147 admissions), had similar race, gender and National Institutes of Health Stroke Scale scores to control sites (1017 admissions). DVT prophylaxis improved more in intervention sites during active-I period (ratio of ORs 4.90, pimproved similarly in both groups during active-I, but control sites improved more in post-I period (ratio of ORs 0.67, p=0.04). In logistic models, the intervention was independently positively associated with DVT performance during active-I period, and negatively associated with dysphagia performance post-I period. Quality improvement training was associated with early DVT improvement, but the effect was not sustained over time and was not seen with dysphagia screening. External quality improvement programmes may quickly boost performance but their effect may vary by indicator and may not sustain over time. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Quality control procedures in positron tomography

    International Nuclear Information System (INIS)

    Spinks, T.; Jones, T.; Heather, J.; Gilardi, M.

    1989-01-01

    The derivation of physiological parameters in positron tomography relies on accurate calibration of the tomograph. Normally, the calibration relates image pixel count density to the count rate from an external blood counter per unit activity concentration in each device. The quality control of the latter is simple and relies on detector stability assessed by measurement of a standard source of similar geometry to a blood sample. The quality control of the tomographic data depends on (i) detector stability, (ii) uniformity of calibration and normalisation sources and (iii) reproducibility of the attenuation correction procedure. A quality control procedure has been developed for an 8 detector ring (15 transaxial plane) tomograph in which detector response is assessed by acquiring data from retractable transmission ring sources. These are scanned daily and a print out of detector efficiencies is produced as well as changes from a given data. This provides the raw data from which decisions on recalibration or renormalisation are made. (orig.)

  20. 21 CFR 862.1660 - Quality control material (assayed and unassayed).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality control material (assayed and unassayed... Test Systems § 862.1660 Quality control material (assayed and unassayed). (a) Identification. A quality... that may arise from reagent or analytical instrument variation. A quality control material (assayed and...

  1. Controlling Subclinical Mastitis by Antibiotic Application during Dry Period of Dairy Cow

    Directory of Open Access Journals (Sweden)

    Imas Sri Nurhayati

    2015-06-01

    Full Text Available Prevention of mastitis is essential, as one of the efforts to control disease in dairy cow. Dry period has implications to understand the mastitis and its control strategies. The udder is very susceptible to be infected both at the beginning and towards the end of dry period. This is linked to physiological changes in udder. Treatment with antibiotics during the dry period can reduce new infection about 82% and has several advantages. The success rate of subclinical mastitis treatment is much higher (80-90% compared to the treatment during lactation (30-40%; the doses of antibiotic can be higher and safer, due to its retention time in udder becomes longer; the risk of antibiotic contamination in milk can be avoided because the udder is not milked. Antibiotic application during dry period is the best way to treat subclinical and chronic mastitis. Treatment during dry period is a specific mastitis control for intramammary infection to avoid economic losses.

  2. Cost and quality effectiveness of objective-based and statistically-based quality control for volatile organic compounds analyses of gases

    International Nuclear Information System (INIS)

    Bennett, J.T.; Crowder, C.A.; Connolly, M.J.

    1994-01-01

    Gas samples from drums of radioactive waste at the Department of Energy (DOE) Idaho National Engineering Laboratory are being characterized for 29 volatile organic compounds to determine the feasibility of storing the waste in DOE's Waste Isolation Pilot Plant (WIPP) in Carlsbad, New Mexico. Quality requirements for the gas chromatography (GC) and GC/mass spectrometry chemical methods used to analyze the waste are specified in the Quality Assurance Program Plan for the WIPP Experimental Waste Characterization Program. Quality requirements consist of both objective criteria (data quality objectives, DQOs) and statistical criteria (process control). The DQOs apply to routine sample analyses, while the statistical criteria serve to determine and monitor precision and accuracy (P ampersand A) of the analysis methods and are also used to assign upper confidence limits to measurement results close to action levels. After over two years and more than 1000 sample analyses there are two general conclusions concerning the two approaches to quality control: (1) Objective criteria (e.g., ± 25% precision, ± 30% accuracy) based on customer needs and the usually prescribed criteria for similar EPA- approved methods are consistently attained during routine analyses. (2) Statistical criteria based on short term method performance are almost an order of magnitude more stringent than objective criteria and are difficult to satisfy following the same routine laboratory procedures which satisfy the objective criteria. A more cost effective and representative approach to establishing statistical method performances criteria would be either to utilize a moving average of P ampersand A from control samples over a several month time period or to determine within a sample variation by one-way analysis of variance of several months replicate sample analysis results or both. Confidence intervals for results near action levels could also be determined by replicate analysis of the sample in

  3. Aflatoxin biosynthesis control produced by Aspergillus flavus in layer hens feed during storage period of six months.

    Science.gov (United States)

    Hassan, S M; Sultana, B; Iqbal, M

    2017-06-01

    Aflatoxins (AFTs) are a group of closely related toxins that are produced by different fungus species. Food and feed contamination with AFT is a worldwide health-related problem. As a result of fungal attack, the food and feed resulted in a principal socioeconomic loss and toxins produced in feed and food items harm the humans and animals in different ways. The anti-aflatoxigenic effect Psidium guajava, Ficus benghalensis, Gardenia radicans, Punica granatum and Ziziphus jujuba leaves were evaluated against aflatoxins (AFTs), produced by Aspergillus flavus in layer feed during storage. Among the investigated medicinal plant leaves, P. granatum showed highly promising anti-aflatoxigenic activity and completely inhibited the AFTs (B1 and B2) production over storage period without compromising the nutritive quality of feed (ash, protein, fat, fiber, Fe, Ca, P and K contents). Leaves of F. benghalensis and Z. jujuba were also effective however, higher concentration (15%) inhibited the AFTs production up to 99% and also maintained nutritive quality of feed. G. radicans was found least effective in controlling the AFTs production. Results revealed that all plant leaves were effective in controlling AFTs production in layer feed over the storage period of six months and these plants are potential candidate to replace the fungicides used to protect feed and other agricultural commodities from AFTs production during storage. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. Quality control in the radioactive waste management

    International Nuclear Information System (INIS)

    Rzyski, B.M.

    1989-01-01

    Radioactive waste management as in industrial activities must mantain in all steps a quality control programme. This control extended from materials acquisition, for waste treatment, to the package deposition is one of the most important activities because it aims to observe the waste acceptance criteria in repositories and allows to guarantee the security of the nuclear facilities. In this work basic knowledges about quality control in waste management and some examples of adopted procedures in other countries are given. (author) [pt

  5. Selection of chemical markers for the quality control of medicinal plants of the genus Cecropia.

    Science.gov (United States)

    Rivera-Mondragón, Andrés; Ortíz, Orlando O; Bijttebier, Sebastiaan; Vlietinck, Arnold; Apers, Sandra; Pieters, Luc; Caballero-George, Catherina

    2017-12-01

    Several Cecropia (Cecropiaceae) species are traditionally used in Latin America for the treatment of a variety of diseases including diabetes, arterial hypertension, asthma, bronchitis, anxiety, and inflammation. At present, a number of commercial products based on these plants have been introduced into the market with very little information on methods for guaranteeing their quality and safety. This work proposes potential chemical markers for the quality control of the raw materials of Cecropia obtusifolia Bertol., Cecropia peltata L., Cecropia glaziovii Snethl., Cecropia pachystachya Trécul, and Cecropia hololeuca Miq. The Herbal Chemical Marker Ranking System (Herb MaRS) developed by the National Institute of Complementary Medicine (NICM) at the University of Western Sydney was used for selecting chemical markers for the quality control of selected medicinal species of Cecropia. This review covers the period from 1982 to 2016. Chlorogenic acid, flavonoidal glycosides (orientin, isoorientin, vitexin, isovitexin, and rutin), catechin, epicatechin, procyanidins (B2, B5, and C1), steroids (β-sitosterol), and triterpenoids (α-amyrin, pomolic, tormentic and ursolic acids) were selected as chemical markers for the quality control of the leaves. It is necessary to establish comprehensive standards for guaranteeing quality, safety and efficacy of herbal drugs. The selection of adequate chemical markers for quality control purposes requires a good knowledge about the chemical composition of medicinal plants and their associated biological properties. To the best of our knowledge this review article is the first to address the identification and quantitative determination of the chemical markers for the genus Cecropia.

  6. PROBLEM OF OPTIMAL CONTROL OF EPIDEMIC IN VIEW OF LATENT PERIOD

    Directory of Open Access Journals (Sweden)

    2017-01-01

    Full Text Available The problem of optimal control of epidemic through vaccination and isolation, taking into account latent period is considered. The target function is minimized - functionality summarizing costs on epidemic prevention and treatment and also considering expenses on infected people left at the end of control T who may be a new source of epidemic. On the left endpoint of the integration segment initial data is given - quantity of infected and confirmed people at the moment t, the right endpoint is free. The dynamic constraints are written by way of a system of simple differential equations describing the speed of changes of number of subjected to infection and number of already infected. Besides the inhomogeneous communi- ty is considered, consisting of four age groups (babies, preschool children, school children and adults. The speed of vaccina- tion (number of vaccinated per a time unit and isolation speed are used as the control functions. There are some restrictions on control above and below. The latent period is described by the constant h and is part of the equation describing the con- tamination speed of people as a retarding in argument t, i.e. a person being in a latent period infects others not being aware of his disease. For problem solving Pontryagin maximum principle is used where it can be seen that the control is piecewise constant. The result of numerical implementation of discrete problem of optimal control is given. The conclusions are made that the latent period significantly influence the incidence rate and as consequence the costs on epidemic suppression. The programme based on the programming language Delphi gives an opportunity to estimate the scale of epidemic at different initial data and restrictions on control as well as to find an optimal control minimizing costs on epimedic suppression.

  7. Quality control in Department of Nuclear Medicine, Clinical Center Banja Luka, RS, Bosnia and Herzegovina

    International Nuclear Information System (INIS)

    Goran Vuleta

    2007-01-01

    Complete test of publication follows. The aim of this work is to give a review of situations in the Department of Nuclear Medicine in Banja Luka related to quality control. We must perform daily, weekly and monthly control of equipment in the Department of Nuclear Medicine, and we must keep records. In our Department we have equipment from different producers and different year of production: 3 gamma cameras (1973, 1989, 2000); 2 auto gamma counters (2000, 2006); 2 dose calibrators (1973, 2000); 1 thyroid uptake system (2000). Normally procedures for quality control are also different. The situation, according to results of quality control is good. All equipment is working normally and with good performance (except one gamma camera - a problem with hard drive), but we don't have a routine daily control and periodical control for others tests. Keeping a records is another problem. Why? 1. In Bosnia and Herzegovina we don't have Regulatory authority. That means that we don't have legislation, rules, inspection or any other regulatory instruments. 2. There is only school for nurses, we have no special school for medical technician. So, we need an education in that field. 3. Very small number of physicist in hospital, no education for medical and nuclear medicine physicist. Conclusion. Situation in Department of Nuclear Medicine in Banja Luka related to quality control is on the medium level. We are trying to put that on the higher level, but to accomplish that we need additional education for nurses (technicians) and physicist.

  8. [Post-marketing reevaluation for potential quality risk and quality control in clinical application of traditional Chinese medicines].

    Science.gov (United States)

    Li, Hong-jiao; He, Li-yun; Liu, Bao-yan

    2015-06-01

    The effective quality control in clinical practices is an effective guarantee for the authenticity and scientificity of the findings. The post-marketing reevaluation for traditional Chinese medicines (TCM) focuses on the efficacy, adverse reaction, combined medication and effective dose of drugs in the market by expanded clinical trials, and requires a larger sample size and a wider range of patients. Therefore, this increases the difficulty of quality control in clinical practices. With the experience in quality control in clinical practices for the post-marketing reevaluation for Kangbingdu oral for cold, researchers in this study reviewed the study purpose, project, scheme design and clinical practice process from an overall point of view, analyzed the study characteristics of the post-marketing reevaluation for TCMs and the quality control risks, designed the quality control contents with quality impacting factors, defined key review contents and summarized the precautions in clinical practices, with the aim to improve the efficiency of quality control of clinical practices. This study can provide reference to clinical units and quality control-related personnel in the post-marketing reevaluation for TCMs.

  9. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-control resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  10. 40 CFR 81.104 - Central Pennsylvania Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.104 Section 81.104 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.104 Central Pennsylvania Intrastate Air Quality Control Region. The Central Pennsylvania Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  11. 40 CFR 81.43 - Metropolitan Toledo Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.43 Section 81.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.43 Metropolitan Toledo Interstate Air Quality Control Region. The Metropolitan Toledo Interstate Air Quality Control Region (Ohio-Michigan) consists of the territorial area...

  12. 40 CFR 81.31 - Metropolitan Providence Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.31 Section 81.31 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.31 Metropolitan Providence Interstate Air Quality Control Region. The Metropolitan Providence Interstate Air Quality Control Region (Rhode Island-Massachusetts) consists of the...

  13. 40 CFR 81.90 - Androscoggin Valley Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.90 Section 81.90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.90 Androscoggin Valley Interstate Air Quality Control Region. The Androscoggin Valley Interstate Air Quality Control Region (Maine-New Hampshire) consists of the territorial...

  14. 40 CFR 81.78 - Metropolitan Portland Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.78 Section 81.78 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.78 Metropolitan Portland Intrastate Air Quality Control Region. The Metropolitan Portland Intrastate Air Quality Control Region (Maine) consists of the territorial area...

  15. 40 CFR 81.30 - Southeastern Wisconsin Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.30 Section 81.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.30 Southeastern Wisconsin Intrastate Air Quality Control Region. The Metropolitan Milwaukee Intrastate Air Quality Control Region (Wisconsin) has been renamed the Southeastern...

  16. 40 CFR 81.16 - Metropolitan Denver Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.16 Section 81.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.16 Metropolitan Denver Intrastate Air Quality Control Region. The Metropolitan Denver Intrastate Air Quality Control Region (Colorado) consists of the territorial area...

  17. 40 CFR 81.47 - Central Oklahoma Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.47 Section 81.47 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.47 Central Oklahoma Intrastate Air Quality Control Region. The Metropolitan Oklahoma Intrastate Air Quality Control Region has been renamed the Central Oklahoma Intrastate...

  18. 40 CFR 81.29 - Metropolitan Indianapolis Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Air Quality Control Region. 81.29 Section 81.29 Protection of Environment ENVIRONMENTAL PROTECTION... Designation of Air Quality Control Regions § 81.29 Metropolitan Indianapolis Intrastate Air Quality Control Region. The Metropolitan Indianapolis Intrastate Air Quality Control Region consists of the territorial...

  19. 40 CFR 81.101 - Metropolitan Dubuque Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.101 Section 81.101 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.101 Metropolitan Dubuque Interstate Air Quality Control Region. The Metropolitan Dubuque Interstate Air Quality Control Region (Illinois-Iowa-Wisconsin) consists of the...

  20. 40 CFR 81.79 - Northeastern Oklahoma Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.79 Section 81.79 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.79 Northeastern Oklahoma Intrastate Air Quality Control Region. The Metropolitan Tulsa Intrastate Air Quality Control Region has been renamed the Northeastern Oklahoma Intrastate...

  1. 40 CFR 81.24 - Niagara Frontier Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.24 Section 81.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.24 Niagara Frontier Intrastate Air Quality Control Region. The Niagara Frontier Intrastate Air Quality Control Region (New York) consists of the territorial area...

  2. 40 CFR 81.106 - Greenville-Spartanburg Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.106 Section 81.106 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.106 Greenville-Spartanburg Intrastate Air Quality Control Region. The Greenville-Spartanburg Intrastate Air Quality Control Region (South Carolina) consists of the territorial...

  3. 40 CFR 81.44 - Metropolitan Memphis Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.44 Section 81.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.44 Metropolitan Memphis Interstate Air Quality Control Region. The Metropolitan Memphis Interstate Air Quality Control Region (Arkansas-Mississippi-Tennessee) consists of the...

  4. 40 CFR 81.19 - Metropolitan Boston Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.19 Section 81.19 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.19 Metropolitan Boston Intrastate Air Quality Control Region. The Metropolitan Boston Intrastate Air Quality Control Region (Massachusetts) consists of the territorial area...

  5. 40 CFR 81.28 - Metropolitan Baltimore Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.28 Section 81.28 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.28 Metropolitan Baltimore Intrastate Air Quality Control Region. The Metropolitan Baltimore Intrastate Air Quality Control Region (Maryland) consists of the territorial area...

  6. 40 CFR 81.119 - Western Tennessee Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.119 Section 81.119 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.119 Western Tennessee Intrastate Air Quality Control Region. The Western Tennessee Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  7. 40 CFR 81.89 - Metropolitan Cheyenne Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.89 Section 81.89 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.89 Metropolitan Cheyenne Intrastate Air Quality Control Region. The Metropolitan Cheyenne Intrastate Air Quality Control Region (Wyoming) consists of the territorial area...

  8. 40 CFR 81.87 - Metropolitan Boise Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.87 Section 81.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.87 Metropolitan Boise Intrastate Air Quality Control Region. The Metropolitan Boise Intrastate Air Quality Control Region (Idaho) consists of the territorial area encompassed...

  9. 40 CFR 81.23 - Southwest Pennsylvania Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.23 Section 81.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.23 Southwest Pennsylvania Intrastate Air Quality Control Region. The Southwest Pennsylvania Intrastate Air Quality Control Region is redesignated to consist of the territorial...

  10. 40 CFR 81.75 - Metropolitan Charlotte Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.75 Section 81.75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.75 Metropolitan Charlotte Interstate Air Quality Control Region. The Metropolitan Charlotte Interstate Air Quality Control Region (North Carolina-South Carolina) has been revised...

  11. 40 CFR 81.120 - Middle Tennessee Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.120 Section 81.120 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.120 Middle Tennessee Intrastate Air Quality Control Region. The Middle Tennessee Intrastate Air Quality Control Region consists of the territorial area encompassed by...

  12. HPLC for quality control of polyimides

    Science.gov (United States)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  13. Solution standards for quality control of nuclear-material analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.

    1981-01-01

    Analytical chemistry measurement control depends upon reliable solution standards. At the Savannah River Plant Control Laboratory over a thousand analytical measurements are made daily for process control, product specification, accountability, and nuclear safety. Large quantities of solution standards are required for a measurement quality control program covering the many different analytical chemistry methods. Savannah River Plant produced uranium, plutonium, neptunium, and americium metals or oxides are dissolved to prepare stock solutions for working or Quality Control Standards (QCS). Because extensive analytical effort is required to characterize or confirm these solutions, they are prepared in large quantities. These stock solutions are diluted and blended with different chemicals and/or each other to synthesize QCS that match the matrices of different process streams. The target uncertainty of a standard's reference value is 10% of the limit of error of the methods used for routine measurements. Standard Reference Materials from NBS are used according to special procedures to calibrate the methods used in measuring the uranium and plutonium standards so traceability can be established. Special precautions are required to minimize the effects of temperature, radiolysis, and evaporation. Standard reference values are periodically corrected to eliminate systematic errors caused by evaporation or decay products. Measurement control is achieved by requiring analysts to analyze a blind QCS each shift a measurement system is used on plant samples. Computer evaluation determines whether or not a measurement is within the +- 3 sigma control limits. Monthly evaluations of the QCS measurements are made to determine current bias correction factors for accountability measurements and detect significant changes in the bias and precision statistics. The evaluations are also used to plan activities for improving the reliability of the analytical chemistry measurements

  14. 40 CFR 81.117 - Southeast Missouri Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.117 Section 81.117 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.117 Southeast Missouri Intrastate Air Quality Control Region. The Southeast Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  15. 40 CFR 81.45 - Metropolitan Atlanta Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.45 Section 81.45 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.45 Metropolitan Atlanta Intrastate Air Quality Control Region. The Metropolitan Atlanta Intrastate Air Quality Control Region (Georgia) has been revised to consist of the...

  16. 40 CFR 81.123 - Southeastern Oklahoma Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.123 Section 81.123 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.123 Southeastern Oklahoma Intrastate Air Quality Control Region. The Southeastern Oklahoma Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  17. 40 CFR 81.98 - Burlington-Keokuk Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.98 Section 81.98 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.98 Burlington-Keokuk Interstate Air Quality Control Region. The Burlington-Keokuk Interstate Air Quality Control Region (Illinois-Iowa) is revised to consist of the...

  18. 40 CFR 81.49 - Southeast Florida Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.49 Section 81.49 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.49 Southeast Florida Intrastate Air Quality Control Region. The Southeast Florida Intrastate Air Quality Control Region is redesignated to consist of the territorial area...

  19. 40 CFR 81.59 - Cumberland-Keyser Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.59 Section 81.59 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.59 Cumberland-Keyser Interstate Air Quality Control Region. The Cumberland-Keyser Interstate Air Quality Control Region (Maryland-West Virginia) has been revised to consist...

  20. 40 CFR 81.20 - Metropolitan Cincinnati Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.20 Section 81.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.20 Metropolitan Cincinnati Interstate Air Quality Control Region. The Metropolitan Cincinnati Interstate Air Quality Control Region (Ohio-Kentucky-Indiana) is revised to consist of...

  1. 40 CFR 81.97 - Southwest Florida Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.97 Section 81.97 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.97 Southwest Florida Intrastate Air Quality Control Region. The Southwest Florida Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  2. 40 CFR 81.116 - Northern Missouri Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.116 Section 81.116 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.116 Northern Missouri Intrastate Air Quality Control Region. The Northern Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  3. 40 CFR 81.67 - Lake Michigan Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.67 Lake Michigan Intrastate Air Quality Control Region. The Menominee-Escanaba (Michigan)-Marinette (Wisconsin) Interstate Air Quality Control Region has been renamed the Lake Michigan Intrastate Air Quality Control Region (Wisconsin) and revised to consist of the territorial area...

  4. 40 CFR 81.34 - Metropolitan Dayton Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.34 Section 81.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.34 Metropolitan Dayton Intrastate Air Quality Control Region. The Metropolitan Dayton Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  5. 40 CFR 81.115 - Northwest Nevada Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.115 Section 81.115 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.115 Northwest Nevada Intrastate Air Quality Control Region. The Northwest Nevada Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  6. 40 CFR 81.41 - Metropolitan Birmingham Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.41 Section 81.41 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.41 Metropolitan Birmingham Intrastate Air Quality Control Region. The Metropolitan Birmingham Intrastate Air Quality Control Region (Alabama) has been revised to consist of the...

  7. 40 CFR 81.14 - Metropolitan Chicago Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.14 Section 81.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.14 Metropolitan Chicago Interstate Air Quality Control Region. The Metropolitan Chicago Interstate Air Quality Control Region (Illinois-Indiana) is revised to consist of the...

  8. 40 CFR 81.118 - Southwest Missouri Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.118 Section 81.118 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.118 Southwest Missouri Intrastate Air Quality Control Region. The Southwest Missouri Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  9. 40 CFR 81.122 - Mississippi Delta Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.122 Section 81.122 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.122 Mississippi Delta Intrastate Air Quality Control Region. The Mississippi Delta Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  10. CONCRETE STRUCTURES' QUALITY CONTROL IN PRACTICE

    OpenAIRE

    Dolaček-Alduk, Zlata; Blanda, Miroslav

    2011-01-01

    The Croatian civil engineering is characterized by a lack of systematic approach to planning, control and quality assurance in all phases of project realization. The results obtained in establishing the quality management system in some segments of civil engineering production represent initial trends in solving this problem. Benefits are of two types: the achievement of quality for the contractor and obtaining that quaity is being achieved for clients. Execution of concrete structures is a c...

  11. National phantoms bank for the service of nuclear medicine in Cuba. Utility for the quality control of the instrumentation

    International Nuclear Information System (INIS)

    Varela C, C.; Diaz B, M.; Lopez B, G.M.

    2006-01-01

    Although, most of the applications in Nuclear Medicine have diagnostic ends, its going enlarging considerably the therapeutic applications. So that the diagnostic accuracy or the therapy effectiveness have not been affected, it becomes indispensable the quality control of the instrumentation, independently of its technological complexity and/or its exploitation period. Before the real lack of phantoms in the institutions, it was created a bank that puts to disposition of all the institutions, the existent phantoms in the country, and those that are going acquired, centralized by the State Control of Medical Equipment Center (CCEEM) and with Web access in its place www.eqmed.sld.cu. Having like base the elaboration of the National Protocol for the Quality Control of the Instrumentation in Nuclear Medicine that keeps in mind the international normative and the own existent conditions, were dictated and established two national regulations and its are being carried out the first audits to the instrumentation quality. These have evidenced the partial realization of the established quality controls in the services, the necessity to make aware as for the fulfillment of the criteria and quality concepts for the instrumentation, as well as the necessity to increase the phantoms number to the bank to guarantee the fulfillment of the Quality Control Programs. (Author)

  12. Technical quality control - constancy controls for digital mammography systems

    International Nuclear Information System (INIS)

    Pedersen, K.; Landmark, I.D.; Bredholt, K.; Hauge, I.H.R.

    2009-04-01

    To ensure the quality of mammographic images, so-called constancy control tests are performed frequently. The report contains a programme for constancy control of digital mammography systems, encompassing the mammography unit, computed radiography (CR) systems, viewing conditions and displays, printers, and procedures for data collection for patient dose calculations. (Author)

  13. 78 FR 16474 - Extension of the Period for Comments on the Enhancement of Quality of Software-Related Patents

    Science.gov (United States)

    2013-03-15

    ...] Extension of the Period for Comments on the Enhancement of Quality of Software-Related Patents AGENCY... announcing the formation of a partnership with the software community to enhance the quality of software... quality of software-related patents and the preparation of software-related patent applications including...

  14. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  15. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    International Nuclear Information System (INIS)

    Fishler, B.

    2011-01-01

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  16. 40 CFR 81.48 - Champlain Valley Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.48 Section 81.48 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.48 Champlain Valley Interstate Air Quality Control Region. The Champlain Valley Interstate Air Quality Control Region (Vermont-New York) has been revised to consist of the...

  17. Concept and realization of quality control in FRG

    International Nuclear Information System (INIS)

    Odoj, R.; Martens, B.R.; Warnecke, E.

    1987-01-01

    Radioactive waste packages to be disposed of in FRG must meet the waste acceptance requirement of the repository. Compliance with the waste acceptance requirements must be checked by a quality control. Fourteen relevant properties are necessary to be assayed. The quality control group supports the observance of the waste acceptance requirements by the following measures: -checking of the documentation of the waste producers; -random tests at conditioned radioactive wastes; -qualification of conditioning processes; -control of the qualified processes by inspections. The relevant properties of disposal are termed and their checking by non-destructive and if necessary destructive test methods will be explained as well as quality control by process control, i.e. qualification of conditioning processes by instrumentation and documentation. The mobile and stationary testing facilities will be outlined

  18. Frontiers in statistical quality control 11

    CERN Document Server

    Schmid, Wolfgang

    2015-01-01

    The main focus of this edited volume is on three major areas of statistical quality control: statistical process control (SPC), acceptance sampling and design of experiments. The majority of the papers deal with statistical process control, while acceptance sampling and design of experiments are also treated to a lesser extent. The book is organized into four thematic parts, with Part I addressing statistical process control. Part II is devoted to acceptance sampling. Part III covers the design of experiments, while Part IV discusses related fields. The twenty-three papers in this volume stem from The 11th International Workshop on Intelligent Statistical Quality Control, which was held in Sydney, Australia from August 20 to August 23, 2013. The event was hosted by Professor Ross Sparks, CSIRO Mathematics, Informatics and Statistics, North Ryde, Australia and was jointly organized by Professors S. Knoth, W. Schmid and Ross Sparks. The papers presented here were carefully selected and reviewed by the scientifi...

  19. Quality control and standardization of forearm X-ray osteodensitometry

    International Nuclear Information System (INIS)

    Boyanov, M.

    2000-01-01

    Quality control (QC) has an essential practical bearing on the proper function of the equipment used for bone density measurement. Special attention is likewise focused on the issue of standardization of the results afforded by different osteodensitometry instruments. It is the purpose of the study to assay QC of a single-energy x-ray forearm osteodensitometry unit DTX-100 covering a 3 year period, and compare the data on bone mineral density (BMD) produced by three different devices. Long-term BMD reproducibility in vitro, expressed as coefficient of variation, amounts to 0.55 per cent. Except for a two week period, no deviation from the normal function of the instrument is documented. Failing to comply with the manufacturer's instructions may discredit QC efficacy. On comparative assessment of the results produced by different osteodensitometers, differences in vivo may reach up to 1.2 standard deviation. Definite regions of special interest, feasible for comparison, are recommended. In conclusion special emphasis is laid on the necessity of performing through QC, measurement results standardization and accreditation of a reference osteodensitometry center

  20. Electronic quality control on dental x-rays equipment

    International Nuclear Information System (INIS)

    Pomares C, Martin

    1996-09-01

    A brief description of dental x-ray equipment is done. The non-invasive quality control is treated as than the responsibilities from the dentists to the patient and the equipment. A propose for quality control for dental x-ray equipment, film and developer is include

  1. APPLICATION OF HIDDEN MARKOV CHAINS IN QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Hanife DEMIRALP

    2013-01-01

    Full Text Available The ever growing technological innovations and sophistication in industrial processes require adequate checks on quality. Thus, there is an increasing demand for simple and efficient quality control methods. In this regard the control charts stand out in simplicity and efficiency. In this paper, we propose a method of controlling quality based on the theory of hidden Markov chains. Based on samples drawn at different times from the production process, the method obtains the state of the process probabilistically. The main advantage of the method is that it requires no assumption on the normality of the process output.

  2. Periodic H-2 Synthesis for Spacecraft Attitude Control with Magnetometers

    DEFF Research Database (Denmark)

    Wisniewski, Rafal; Stoustrup, Jakob

    2004-01-01

    between the Earth´s magnetic field and an artificial magnetic field generated by the coils produces a control torque. The magnetic attitude control is intrinsically periodic due to cyclic variation of the geomagnetic field in orbit. The control performance is specified by the generalized H2 operator norm....... A linear matrix inequality-based algorithm is proposed for attitude control synthesis. Simulation results are provided, showing the prospect of the concept for onboard implementation....

  3. Automating PACS Quality Control with the Vanderbilt Image Processing Enterprise Resource.

    Science.gov (United States)

    Esparza, Michael L; Welch, E Brian; Landman, Bennett A

    2012-02-12

    Precise image acquisition is an integral part of modern patient care and medical imaging research. Periodic quality control using standardized protocols and phantoms ensures that scanners are operating according to specifications, yet such procedures do not ensure that individual datasets are free from corruption-for example due to patient motion, transient interference, or physiological variability. If unacceptable artifacts are noticed during scanning, a technologist can repeat a procedure. Yet, substantial delays may be incurred if a problematic scan is not noticed until a radiologist reads the scans or an automated algorithm fails. Given scores of slices in typical three-dimensional scans and wide-variety of potential use cases, a technologist cannot practically be expected inspect all images. In large-scale research, automated pipeline systems have had great success in achieving high throughput. However, clinical and institutional workflows are largely based on DICOM and PACS technologies; these systems are not readily compatible with research systems due to security and privacy restrictions. Hence, quantitative quality control has been relegated to individual investigators and too often neglected. Herein, we propose a scalable system, the Vanderbilt Image Processing Enterprise Resource-VIPER, to integrate modular quality control and image analysis routines with a standard PACS configuration. This server unifies image processing routines across an institutional level and provides a simple interface so that investigators can collaborate to deploy new analysis technologies. VIPER integrates with high performance computing environments has successfully analyzed all standard scans from our institutional research center over the course of the last 18 months.

  4. 22 CFR 96.39 - Information disclosure and quality control practices.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Information disclosure and quality control... for Convention Accreditation and Approval Information Disclosure, Fee Practices, and Quality Control Policies and Practices § 96.39 Information disclosure and quality control practices. (a) The agency or...

  5. SALE, Quality Control of Analytical Chemical Measurements

    International Nuclear Information System (INIS)

    Bush, W.J.; Gentillon, C.D.

    1985-01-01

    1 - Description of problem or function: The Safeguards Analytical Laboratory Evaluation (SALE) program is a statistical analysis program written to analyze the data received from laboratories participating in the SALE quality control and evaluation program. The system is aimed at identifying and reducing analytical chemical measurement errors. Samples of well-characterized materials are distributed to laboratory participants at periodic intervals for determination of uranium or plutonium concentration and isotopic distributions. The results of these determinations are statistically evaluated and participants are informed of the accuracy and precision of their results. 2 - Method of solution: Various statistical techniques produce the SALE output. Assuming an unbalanced nested design, an analysis of variance is performed, resulting in a test of significance for time and analyst effects. A trend test is performed. Both within- laboratory and between-laboratory standard deviations are calculated. 3 - Restrictions on the complexity of the problem: Up to 1500 pieces of data for each nuclear material sampled by a maximum of 75 laboratories may be analyzed

  6. Ocean Data Quality Control

    Science.gov (United States)

    2011-11-18

    the aero- sol at the coincident time and location of the satellite SST retrievals. This informa- tion is available in the daytime for the anti-solar...are of the same form, such as probabilities or standard normal deviates. A quality control decision-making algorithm in use at the U.S. Navy oceano

  7. Some observations about quality control tests of Spect

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.

    1987-01-01

    Some observations about quality control tests done in the tomographic system of Heart Institute are described. Among the tests, the traditional test of quality control with scintillation camera and the specific test for tomography systems are induced. The traditional tests are essential, but not sufficient for evaluating the Spect equipment and the specific tests have been effectuated in controlled conditions. (C.G.C.) [pt

  8. Quality Controlling CMIP datasets at GFDL

    Science.gov (United States)

    Horowitz, L. W.; Radhakrishnan, A.; Balaji, V.; Adcroft, A.; Krasting, J. P.; Nikonov, S.; Mason, E. E.; Schweitzer, R.; Nadeau, D.

    2017-12-01

    As GFDL makes the switch from model development to production in light of the Climate Model Intercomparison Project (CMIP), GFDL's efforts are shifted to testing and more importantly establishing guidelines and protocols for Quality Controlling and semi-automated data publishing. Every CMIP cycle introduces key challenges and the upcoming CMIP6 is no exception. The new CMIP experimental design comprises of multiple MIPs facilitating research in different focus areas. This paradigm has implications not only for the groups that develop the models and conduct the runs, but also for the groups that monitor, analyze and quality control the datasets before data publishing, before their knowledge makes its way into reports like the IPCC (Intergovernmental Panel on Climate Change) Assessment Reports. In this talk, we discuss some of the paths taken at GFDL to quality control the CMIP-ready datasets including: Jupyter notebooks, PrePARE, LAMP (Linux, Apache, MySQL, PHP/Python/Perl): technology-driven tracker system to monitor the status of experiments qualitatively and quantitatively, provide additional metadata and analysis services along with some in-built controlled-vocabulary validations in the workflow. In addition to this, we also discuss the integration of community-based model evaluation software (ESMValTool, PCMDI Metrics Package, and ILAMB) as part of our CMIP6 workflow.

  9. Production process and quality control for the HTTR fuel

    International Nuclear Information System (INIS)

    Yoshimuta, S.; Suzuki, N.; Kaneko, M.; Fukuda, K.

    1991-01-01

    Development of the production and inspection technology for High Temperature Engineering Test Reactor (HTTR) fuel has been carried out by cooperative work between Japan Atomic Energy Research Institute (JAERI) and Nuclear Fuel Industries, Ltd (NFI). The performance and the quality level of the developed fuel are well established to meet the design requirements of the HTTR. For the commercial scale production of the fuel, statistical quality control and quality assurance must be carefully considered in order to assure the safety of the HTTR. It is also important to produce the fuel under well controlled process condition. To meet these requirements in the production of the HTTR fuel, a new production process and quality control system is to be introduced in the new facilities. The main feature of the system is a computer integrated control system. Process control data at each production stage of products and semi-products are all gathered by terminal computers and processed by a host computer. The processed information is effectively used for the production, quality and accountancy control. With the aid of this system, all the products will be easily traceable from starting materials to final stages and the statistical evaluation of the quality of products becomes more reliable. (author). 8 figs

  10. 40 CFR 81.76 - State of Hawaii Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false State of Hawaii Air Quality Control... PROGRAMS (CONTINUED) DESIGNATION OF AREAS FOR AIR QUALITY PLANNING PURPOSES Designation of Air Quality Control Regions § 81.76 State of Hawaii Air Quality Control Region. The State of Hawaii Air Quality...

  11. Demographic and quality control parameters of Anastrepha Fraterculus (Diptera: Tephritidae) maintained under artificial rearing

    International Nuclear Information System (INIS)

    Vera, T.; Abraham, S.; Oviedo, A.; Willink, E.

    2007-01-01

    The integration of the sterile insect technique (SIT) in the management of the South American fruit fly Anastrepha fraterculus (Wiedemann) (Diptera: Tephritidae) is a promising alternative to chemically-based control in those areas where it is sympatric with Ceratitis capitata (Wiedemann) (Diptera: Tephritidae) or other tephritid species for which the SIT is being used. Implementation of the SIT requires the development of a cost effective mass-rearing protocol. In this work, we present demographic and quality control parameters for the A. fraterculus strain reared at the Estacion Experimental Agroindustrial Obispo Colombres, Tucuman, Argentina. Considering the rearing cage as the reproduction unit, we observed that fecundity is optimal during the first 3 weeks after the onset of oviposition. Fertility was constant during this period. During 2003 and 2004, some improvements were made to the existing rearing protocol, which resulted in increased larval viability, pupal weight, and adult emergence. Current weekly egg production is 1 million per week. These eggs are used to maintain the colony and to assess quality parameters. Finally, research needs leading to improved yields and fly quality are discussed. (author) [es

  12. Technology requirement for Halal quality control | Husny | Journal of ...

    African Journals Online (AJOL)

    Technology requirement for Halal quality control. ... Findings show that each industry segments have different technology characteristics preference. ... Keywords: halal industry, quality control; technology assistance; food and beverage; ...

  13. Internal cost control on the ecological quality of products

    Directory of Open Access Journals (Sweden)

    N.P. Syroid

    2018-04-01

    Full Text Available To improve the environmental quality of products due attention should be paid to control the processes related to environmental quality input of the product. The results of the study help to state the purpose and objectives of the control, also to define objects for internal control of operations cost of environmental quality. So, we believe that the main purpose of internal cost control on the ecological quality of products is the establishment of the correctness and legality of business operations, prevention of violations and abuses in the expenditure of natural, labour, material and financial resources to ensure the minimization of negative impact on the health of consumers and the environment. The basic objectives of internal control of expenditure are brought forward, but it should be noted that they can vary and depend on the size, structure, spheres and types of economic activity of the enterprise, the requirements of management personnel. In the process of identifying the objects of control of environmental quality it should be noted that this list is not exhaustive, but it is most relevant to highlight objects such as genetically modified organisms and waste production. Also the subjects of cost control to environmental quality, their functions and the information base for monitoring are determined. Proper organization of the process of internal cost control on the ecological quality of products would benefit from a clear documentation of transactions, timely and complete registration of accounting data in the registers, the true reflection of information in managerial financial reporting and ensure reduction of the negative impact on the health of consumers and the environment.

  14. Internal quality control: planning and implementation strategies.

    Science.gov (United States)

    Westgard, James O

    2003-11-01

    The first essential in setting up internal quality control (IQC) of a test procedure in the clinical laboratory is to select the proper IQC procedure to implement, i.e. choosing the statistical criteria or control rules, and the number of control measurements, according to the quality required for the test and the observed performance of the method. Then the right IQC procedure must be properly implemented. This review focuses on strategies for planning and implementing IQC procedures in order to improve the quality of the IQC. A quantitative planning process is described that can be implemented with graphical tools such as power function or critical-error graphs and charts of operating specifications. Finally, a total QC strategy is formulated to minimize cost and maximize quality. A general strategy for IQC implementation is recommended that employs a three-stage design in which the first stage provides high error detection, the second stage low false rejection and the third stage prescribes the length of the analytical run, making use of an algorithm involving the average of normal patients' data.

  15. Development and implementation of quality control strategies for CMS silicon strip tracker modules

    CERN Document Server

    Dirkes, Guido

    The LHC will explore physics at the energy frontier and will address many open questions in particle physics, like the search for the Higgs boson or Supersymmetry. For both high resolution track and vertex reconstruction is vital. The CMS silicon tracker consists of 15232 detector modules. Production and assembly of these will span two and a half years period, during which the quality control chain has to ensure functionality and reliability of the modules produced. The CMS group in Karlsruhe will produce and qualify 1600 modules. Therefore automatic test systems are developed and test strategies are worked out. Already during the RnD phase, first prototype tests were performed and some weak points of the design were uncovered. Two test stations are built. One focuses on a fast functionality test, including an active thermal cycle. The other focuses on debugging and repair requirements, including additional test options with lasers, radioactive sources, probes and infrared LEDs. For quality control measuremen...

  16. Quality control in diagnostic radiology - patient dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Prlic, I; Radalj, Z; Brumen, V; Cerovac, H [Institute for Medical Research and Occupational Health, Laboratory for Radiation Protection and Dosimetry, Zagreb (Croatia); Gladic, J [Institute for Physics, Laboratory for Solid State Physics, Zagreb (Croatia); Tercek, V [Clinical Hospital Sisters of Mercy, Health Physics Department, Zagreb (Croatia)

    1997-12-31

    In order to establish the Quality Criteria for diagnostic radiographic images in the radiology departments in Republic of Croatia we have started the several Quality Control projects on the field. The measurements are performed according to some methodology recommendations in our law but the methodology, measurement principles, measurement equipment, phantoms, measurable parameters for the good use by radiographers, statistical and numerical evaluation, dosimetric philosophy etc. where first recognized as a private/or group hazard of each person involved in the procedure of evaluation of diagnostic radiology images/diagnosis. The important quality elements of the imaging process are: the diagnostic quality of the radiographic image, the radiation dose to the patient and the choice of the radiographic technique. This depends on the x-ray unit (tube) radiation quality, image processing quality and final image evaluation quality. In this paper we will show how the Quality Control measurements can be easily connected to the dose delivered to the patient for the known diagnostic procedure and how this can be used by radiographers in their daily work. The reproducibility of the x-ray generator was checked before the service calibration and after the service calibration. The table of kV dependence and output dose per mAs was calculated and the ESD (entrance surface dose) was measured/calculated for the specific diagnostic procedure. After the phantom calculation were made and the dose prediction for the given procedure was done, measurements were done on the patients (digital dosemeters, TLD and film dosemeter combinations). We are claiming that there is no need to measure each patient if the proper Quality Control measurements are done and the proper table of ESD for each particular x-ray tube in diagnostic departments is calculated for the radiographers daily use. (author). 1 example, 1 fig., 13 refs.

  17. The regulatory maze of quality control

    International Nuclear Information System (INIS)

    Stone, T.I.

    1987-01-01

    The appropriateness of specific procedures within a quality control program becomes difficult to assess when an attempt is made to collate all of the available information. This task is discussed from the perspective of the Joint Commission (JCAH Accreditation Manual), HHS(quality assurance program recommendations), equipment manufacturers maintenance schedules, and radiology administrative cost concerns

  18. Advanced methods of quality control in nuclear fuel fabrication

    International Nuclear Information System (INIS)

    Onoufriev, Vladimir

    2004-01-01

    Under pressure of current economic and electricity market situation utilities implement more demanding fuel utilization schemes including higher burn ups and thermal rates, longer fuel cycles and usage of Mo fuel. Therefore, fuel vendors have recently initiated new R and D programmes aimed at improving fuel quality, design and materials to produce robust and reliable fuel. In the beginning of commercial fuel fabrication, emphasis was given to advancements in Quality Control/Quality Assurance related mainly to product itself. During recent years, emphasis was transferred to improvements in process control and to implementation of overall Total Quality Management (TQM) programmes. In the area of fuel quality control, statistical control methods are now widely implemented replacing 100% inspection. This evolution, some practical examples and IAEA activities are described in the paper. The paper presents major findings of the latest IAEA Technical Meetings (TMs) and training courses in the area with emphasis on information received at the TM and training course held in 1999 and other latest publications to provide an overview of new developments in process/quality control, their implementation and results obtained including new approaches to QC

  19. Quality control of PET/CT

    International Nuclear Information System (INIS)

    Angelova, J.; Zajcharov, M.

    2013-01-01

    Full text: Introduction: The aim of this work is to undertake a review of the methods for checking and adjusting the computer and positron emission tomography in the Hospital 'Alexandrovska' by the attached to the equipment phantoms according to the manufacturer prescription in order to fulfill its requirements for the entry of the main parameters image within certain limits. Materials and Methods: At the start of work a check of the lasers setting for patient positioning and 'heat' of the X-ray tube scanner to better image quality were made. Daily verification procedures on the image quality of CT through the water phantom and weekly - 'air' calibration were carried out. In positron part, daily control involves setting the resolution and sensitivity of the scanner through built Ga68 phantom. When commissioning, after repair and at least once a year, it is necessary to verify the accuracy of registration of the pulses from the crystal with a water phantom of known volume and the coincidence between CT and PET image. Results: The process of quality control is interactive. The results are displayed in tables and graphically, with the goal the individual values to fall within the determined by manufacturers range and to meet the standards for image quality. If necessary, the procedure repeats several times until it is fulfilled. Conclusion: Ensuring the quality of the image in positron emission tomography combined with computed tomography, is inextricably linked to accurate and precise diagnosis of tumor processes in the human body

  20. Information-Quality based LV-Grid-Monitoring Framework and its Application to Power-Quality Control

    DEFF Research Database (Denmark)

    Findrik, Mislav; Kristensen, Thomas le Fevre; Hinterhofer, Thomas

    2015-01-01

    The integration of unpredictable renewable energy sources into the low voltage (LV) power grid results in new challenges when it comes to ensuring power quality in the electrical grid. Addressing this problem requires control of not only the secondary substation but also control of flexible assets...... inside the LV grid. In this paper we investigate how the flexibility information of such assets can be accessed by the controller using heterogeneous off-the-shelf communication networks. To achieve this we develop an adaptive monitoring framework, through which the controller can subscribe to the assets......' flexibility information through an API. We define an information quality metric making the monitoring framework able to adapt information access strategies to ensure the information is made available to the controller with the highest possible information quality. To evaluate the monitoring framework...

  1. Reward acts as a signal to control delay-period activity in delayed-response tasks.

    Science.gov (United States)

    Ichihara-Takeda, Satoe; Takeda, Kazuyoshi; Funahashi, Shintaro

    2010-03-31

    Prefrontal delay-period activity represents a neural mechanism for the active maintenance of information and needs to be controlled by some signal to appropriately operate working memory. To examine whether reward-delivery acts as this signal, the effects of delay-period activity in response to unexpected reward-delivery were examined by analyzing single-neuron activity recorded in the primate dorsolateral prefrontal cortex. Among neurons that showed delay-period activity, 34% showed inhibition of this activity in response to unexpected reward-delivery. The delay-period activity of these neurons was affected by the expectation of reward-delivery. The strength of the reward signal in controlling the delay-period activity is related to the strength of the effect of reward information on the delay-period activity. These results indicate that reward-delivery acts as a signal to control delay-period activity.

  2. Quality control protocols for radiodiagnosis agents and radiopharmaceuticals

    International Nuclear Information System (INIS)

    Robles, A.; Condor, M.; Caballero, J.; Morote, M.; Garcia, C.; Benites, M.

    1997-01-01

    Based on the compilation of pharmacopoeia methods, literature, manuals and other information developed in our laboratory, protocols have been prepared to carry out quality controls for radiodiagnosis agents (RDA), better known as kits and RDA labelled with Tc99m. Quality control protocols cover physicochemical and biological controls. Physicochemical controls described for RDA include physical characteristics, particle size and number, pH, chemical identification, humidity, tin II; whereas biological controls include sterility, acute toxicity and bacterial endotoxin determination (LAL). Physicochemical controls described for radiopharmaceuticals labelled with Tc99m are pH and radiochemical purity; while biological distribution is described as a biological control

  3. COMP report: CPQR technical quality control guidelines for low-dose-rate permanent seed brachytherapy.

    Science.gov (United States)

    Beaulieu, Luc; Radford, Dee-Ann; Eduardo Villarreal-Barajas, J

    2018-03-14

    The Canadian Organization of Medical Physicists (COMP), in close partnership with the Canadian Partnership for Quality Radiotherapy (CPQR) has developed a series of Technical Quality Control (TQC) guidelines for radiation treatment equipment. These guidelines outline the performance objectives that equipment should meet in order to ensure an acceptable level of radiation treatment quality. The TQC guidelines have been rigorously reviewed and field tested in a variety of Canadian radiation treatment facilities. The development process enables rapid review and update to keep the guidelines current with changes in technology. This article contains detailed performance objectives and safety criteria for low-dose-rate (LDR) permanent seed brachytherapy. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  4. Quality control of conventional radiographic facilities in Kinshasa

    International Nuclear Information System (INIS)

    Woto, M.L.; Lukanda, M.V.; Mulumba, L.C.P.; Palangu

    2009-01-01

    The continuous development of medical applications of ionizing radiation, due to the benefit derived by diagnostic or therapeutic patients, their diversity, ease of implementation, explains the importance of medical exposure. The latter is currently the leading cause of human exposure to artificial origin. The purpose of this study is to contribute to the optimization of radiographic facilities in the city of Kinshasa. This study has revealed that city of Kinshasa has an average of 122 medical training with conventional radiology facilities distributed in six districts of health. Of the 122 facilities, only 30 (or 24.59%) are controlled from the point of view of quality assurance. Some generators and X-ray tubes are respectively controlled adjustment and de centered, and other devices are cannibalized. So, nationally and particularly in Kinshasa, quality control equipment and diagnostic facilities is at a generally delayed compared with international recommendations of X W. Major efforts must be made at government level to raise awareness and establish a quality assurance program in diagnostic radiology. An awareness of the entire medical profession and the competent administrative authorities of medical devices could be beneficial to the quality of care delivered to patients, limiting radiation exposure and improving image quality and only the financial balance of the health sector. The delivery of quality care passes through the justification of acts, the development and dissemination of good practice references and the establishment of quality control radiological installations.

  5. Measurement of urinary porphyrins and porphyrin precursors in Dutch hospital laboratories: a review of quality control over 5 years.

    NARCIS (Netherlands)

    Zuijderhoudt, F.M.; Weykamp, C.W.; Willems, J.L.

    2003-01-01

    BACKGROUND: We evaluated a quality control scheme for the measurement of urinary uroporphyrin, coproporphyrin, total urinary porphyrins and precursors of urinary porphyrins, delta-aminolevulinic acid and porphobilinogen that was performed in The Netherlands during a period of 5 years. METHODS: Six

  6. Quality control of radiodiagnostics

    International Nuclear Information System (INIS)

    Alonso Diaz, M.; Castaneda Arronte, M.J.; Matorras Galan, P.; Diaz-Caneja Rodriguez, N.; Gutierrez Diaz Velarde, I.

    1993-01-01

    Since May 1990, a program of quality control of diagnostic X-ray equipment is underway in the University Hospital Marques de Valdecilla. This includes the design and application of measuring specifications and procedures corresponding to the different parameters of the equipment. The specified values are presented, as are those obtained for geometric and exposition parameters using the equipment. The specifications for the geometric parameters are fulfilled in an large proportion (between 52 and 86%) of the units, and the rest can easily be adjusted. However, 85% of the units can be made to operate with a field larger than that of the screen of the image monitor and approximately half of them can operate at a shorter focus-to-patient distance than that specified. With respect to the exposition parameters, in general, these units do not fulfill the specifications and their behavior is not uniform. The results obtained indicate that the equipment studied could be made to comply with the proposed specifications if a Maintenance Program were initiated in coordination with that of Quality Control. (Author)

  7. Management Model for efficient quality control in new buildings

    Directory of Open Access Journals (Sweden)

    C. E. Rodríguez-Jiménez

    2017-09-01

    Full Text Available The management of the quality control of each building process is usually set up in Spain from different levels of demand. This work tries to obtain a model of reference, to compare the quality control of the building process of a specific product (building, and to be able to evaluate its warranty level. In the quest of this purpose, we take credit of specialized sources and 153 real cases of Quality Control were carefully revised using a multi-judgment method. Applying different techniques to get a specific valuation (impartial of the input parameters through Delphi’s method (17 experts query, whose matrix treatment with the Fuzzy-QFD tool condenses numerical references through a weighted distribution of the selected functions and their corresponding conditioning factors. The model thus obtained (M153 is useful in order to have a quality control reference to meet the expectations of the quality.

  8. Exposure parameters in fluoroscopy equipment. Quality control

    International Nuclear Information System (INIS)

    Alonso, M.; Castaneda, M.J.; Matorras, P.; Diaz-Caneja, N.; Gutierrez, I.

    1992-01-01

    Within the quality control program in Diagnostic Radiology currently being undertaken at the 'Marques de Valdecilla' University Hospital, the corresponding specification and procedure prototypes for the control of conventional radioscopy equipment have been elaborated and applied. This paper presents the values proposed in the specifications and those obtained for the following radioscopy equipment parameters: reference kerma, and its reproducibility, kerma linearity, maximum kerma at the skin, and total filtration. The results obtained indicate that the equipment studied could comply with specified requirements if a Maintenance Program were to be implemented in coordination with the Quality Control Program. (author)

  9. SAQC: SNP Array Quality Control

    Directory of Open Access Journals (Sweden)

    Li Ling-Hui

    2011-04-01

    Full Text Available Abstract Background Genome-wide single-nucleotide polymorphism (SNP arrays containing hundreds of thousands of SNPs from the human genome have proven useful for studying important human genome questions. Data quality of SNP arrays plays a key role in the accuracy and precision of downstream data analyses. However, good indices for assessing data quality of SNP arrays have not yet been developed. Results We developed new quality indices to measure the quality of SNP arrays and/or DNA samples and investigated their statistical properties. The indices quantify a departure of estimated individual-level allele frequencies (AFs from expected frequencies via standardized distances. The proposed quality indices followed lognormal distributions in several large genomic studies that we empirically evaluated. AF reference data and quality index reference data for different SNP array platforms were established based on samples from various reference populations. Furthermore, a confidence interval method based on the underlying empirical distributions of quality indices was developed to identify poor-quality SNP arrays and/or DNA samples. Analyses of authentic biological data and simulated data show that this new method is sensitive and specific for the detection of poor-quality SNP arrays and/or DNA samples. Conclusions This study introduces new quality indices, establishes references for AFs and quality indices, and develops a detection method for poor-quality SNP arrays and/or DNA samples. We have developed a new computer program that utilizes these methods called SNP Array Quality Control (SAQC. SAQC software is written in R and R-GUI and was developed as a user-friendly tool for the visualization and evaluation of data quality of genome-wide SNP arrays. The program is available online (http://www.stat.sinica.edu.tw/hsinchou/genetics/quality/SAQC.htm.

  10. HANDBOOK: QUALITY ASSURANCE/QUALITY CONTROL (QA/QC) PROCEDURES FOR HAZARDOUS WASTE INCINERATION

    Science.gov (United States)

    Resource Conservation and Recovery Act regulations for hazardous waste incineration require trial burns by permit applicants. uality Assurance Project Plan (QAPjP) must accompany a trial burn plan with appropriate quality assurance/quality control procedures. uidance on the prepa...

  11. Quality control system response to stochastic growth of amyloid fibrils

    DEFF Research Database (Denmark)

    Pigolotti, S.; Lizana, L.; Sneppen, K.

    2013-01-01

    We introduce a stochastic model describing aggregation of misfolded proteins and degradation by the protein quality control system in a single cell. Aggregate growth is contrasted by the cell quality control system, that attacks them at different stages of the growth process, with an efficiency...... that decreases with their size. Model parameters are estimated from experimental data. Two qualitatively different behaviors emerge: a homeostatic state, where the quality control system is stable and aggregates of large sizes are not formed, and an oscillatory state, where the quality control system...

  12. Quality control in haemostasis.

    Science.gov (United States)

    Capel, P; Chatelain, B; Leclerq, R; Lust, A; Masure, R; Arnout, J

    1992-01-01

    Laboratory investigation of the haemostatic system deserves particular procedures in the quality control of analytical variables as well as preanalytical variables. This paper reviews the precautions that have to be taken in the blood prelevement, the transport of the tubes and the performance of the laboratory tests aimed to investigate the haemostatic system in order to obtain reliable results.

  13. USE OF INTELLECTUAL TECHNOLOGIES FOR QUALITY CONTROL OF CURD

    Directory of Open Access Journals (Sweden)

    M. M. Blagoveshchenskaya

    2015-01-01

    Full Text Available In this article, we consider additional method of quality control of curds by organoleptic properties. Method consists in construction of neural network model to estimate quality of curds by input and output parameters. Quality control of curds by organoleptic properties is not necessary according to state standard specification, therefore we use exemplary 5-score scale for organoleptic estimation. Author gives an example of fundamental operation which is necessary for neural networks projection and gives recommendation for integrated hardware/software solution design. This method makes easier quality control of final product because operator can react on digression in the technological process in proper time (use data recommended by neural network, predict quality of final product in case when technological parameters deviate from the norm.

  14. Quality control of labelled compounds

    International Nuclear Information System (INIS)

    Matucha, M.

    1979-01-01

    Some advantages and disadvantages of methods used for quality control of organic labelled compounds (1 31 I, 14 C) are shortly discussed. The methods used are electrophoresis, ultraviolet and infrared spectrometry, radiogas and thin-layer chromatography. (author)

  15. Quality control of mammography

    International Nuclear Information System (INIS)

    Hering, K.G.

    1986-01-01

    Random checks of mammograms allow to clearly assess quality controls concerning correct application and operation of the radiographic system indicated by rich contrast in breast tissue images, complete imaging of the mammary parenchyma, freedom from blurs due to motion, efficient breast compression, correct film labelling and perfect maintenance of the film screen system. In addition to these subjective assessments, the following points should be considered when using objective measurement procedures and phantoms: Testing the correct function of X-ray and radiographic equipment by means of test specimens to measure KV standard (KV=Association of German Panel Doctors), mAS and automatic exposure timer; comparing dose and density to initial values and checking film processing by using a sensitometer. Quality assurance handling varies from one KV to the next. That is why the users need to obtain the guidelines of the respective KV relative to radiological quality assurance and to proceed according to these. (orig.) [de

  16. 40 CFR 81.17 - Metropolitan Los Angeles Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.17 Metropolitan Los Angeles Air Quality Control Region. The Metropolitan Los Angeles Air Quality Control Region consists of the following territorial area (including the territorial... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Metropolitan Los Angeles Air Quality...

  17. 40 CFR 81.32 - Puget Sound Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.32 Puget Sound Intrastate Air Quality Control Region. The Puget Sound Intrastate Air Quality Control Region (Washington) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Puget Sound Intrastate Air Quality...

  18. 7 CFR 58.442 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  19. Quality control of CANDU6 fuel element in fabrication process

    International Nuclear Information System (INIS)

    Li Yinxie; Zhang Jie

    2012-01-01

    To enhance the fine control over all aspects of the production process, improve product quality, fuel element fabrication process for CANDU6 quality process control activities carried out by professional technical and management technology combined mode, the quality of the fuel elements formed around CANDU6 weak links - - end plug , and brazing processes and procedures associated with this aspect of strict control, in improving staff quality consciousness, strengthening equipment maintenance, improved tooling, fixtures, optimization process test, strengthen supervision, fine inspection operations, timely delivery carry out aspects of the quality of information and concerns the production environment, etc., to find the problem from the improvement of product quality and factors affecting the source, and resolved to form the active control, comprehensive and systematic analysis of the problem of the quality management concepts, effectively reducing the end plug weld microstructure after the failure times and number of defects zirconium alloys brazed, improved product quality, and created economic benefits expressly provided, while staff quality consciousness and attention to detail, collaboration department, communication has been greatly improved and achieved very good management effectiveness. (authors)

  20. Quality control in paediatric nuclear medicine

    International Nuclear Information System (INIS)

    Fischer, S.; Hahn, K.

    1997-01-01

    Nuclear medicine examinations in children require a maximum in quality. This is true for the preparation of the child and parents, the imaging procedure, processing and documentation. It is necessary that quality control through all steps is performed regularly. The aim must be that the children receive a minimum radiation dose, while there needs to be a high quality in imaging and clinical information from the study. Furthermore the child should not be too much psychologically affected by the nuclear medicine examination. (orig.) [de

  1. Quality assurance and quality control in fabrication of heat exchanger tubes

    International Nuclear Information System (INIS)

    Duennewald, A.

    1980-01-01

    Object of this report is the manufacture of heat exchanger tubes. A comprehensive manufacturing and test program has to be established to assure and prove and equal tube quality. This requires a functionally operating quality assurance system combined with a production exactly planned in advance. A specific continuous production line for heat exchanger tubes has been erected at the Hellenthal plant of the Mannesmannroehren-Werke. All production steps and heat treatments are generally controlled by a quality control department. Non-destructive testing of each tube produced in standard length is performed on several agregates in line using ultrasonic and/or eddy current technique. All tests are generally performed in the presence of quality inspectors or surveyors. For a lot of heat exchangers the straight tubes have to be hairpin bended. To avoid the risk of stress corrosion cracking, it is recommended to procreate defined compression stresses in the outside tube surface. Prior to releasing the tubes to shipment, the completeness of the documentation as to the manufacturing steps and inspection agreed upon is thoroughly checked. (RW)

  2. Radiation measurements and quality control

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1977-01-01

    Accurate measurements are essential to research leading to a successful radiation process and to the commissioning of the process and the facility. On the other hand, once the process is in production, the importance to quality control of measuring radiation quantities (i.e., absorbed dose, dose rate, dose distribution) rather than various other parameters of the process (i.e. conveyor speed, dwell time, radiation field characteristics, product dimensions) is not clearly established. When the safety of the product is determined by the magnitude of the administered dose, as in radiation sterilization, waste control, or food preservation, accuracy and precision of the measurement of the effective dose are vital. Since physical dose measurements are usually simpler, more reliable and reproducible than biological testing of the product, there is a trend toward using standardized dosimetry for quality control of some processes. In many industrial products, however, such as vulcanized rubber, textiles, plastics, coatings, films, wire and cable, the effective dose can be controlled satisfactorily by controlling process variables or by product testing itself. In the measurement of radiation dose profiles by dosimetry, it is necessary to have suitable dose meter calibrations, to account for sources of error and imprecision, and to use correct statistical procedures in specifying dwell times or conveyor speeds and source and product parameters to achieve minimum and maximum doses within specifications. (author)

  3. Periodic reference tracking control approach for smart material actuators with complex hysteretic characteristics

    Science.gov (United States)

    Sun, Zhiyong; Hao, Lina; Song, Bo; Yang, Ruiguo; Cao, Ruimin; Cheng, Yu

    2016-10-01

    Micro/nano positioning technologies have been attractive for decades for their various applications in both industrial and scientific fields. The actuators employed in these technologies are typically smart material actuators, which possess inherent hysteresis that may cause systems behave unexpectedly. Periodic reference tracking capability is fundamental for apparatuses such as scanning probe microscope, which employs smart material actuators to generate periodic scanning motion. However, traditional controller such as PID method cannot guarantee accurate fast periodic scanning motion. To tackle this problem and to conduct practical implementation in digital devices, this paper proposes a novel control method named discrete extended unparallel Prandtl-Ishlinskii model based internal model (d-EUPI-IM) control approach. To tackle modeling uncertainties, the robust d-EUPI-IM control approach is investigated, and the associated sufficient stabilizing conditions are derived. The advantages of the proposed controller are: it is designed and represented in discrete form, thus practical for digital devices implementation; the extended unparallel Prandtl-Ishlinskii model can precisely represent forward/inverse complex hysteretic characteristics, thus can reduce modeling uncertainties and benefits controllers design; in addition, the internal model principle based control module can be utilized as a natural oscillator for tackling periodic references tracking problem. The proposed controller was verified through comparative experiments on a piezoelectric actuator platform, and convincing results have been achieved.

  4. Descriptive study of the quality control in mammography; Estudio descriptivo del control de calidad en mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M. [UAM, Xochimilco 14000 Mexico D.F. (Mexico)

    2005-07-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  5. 40 CFR 81.110 - Camden-Sumter Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.110 Camden-Sumter Intrastate Air Quality Control Region. The Camden-Sumter Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Camden-Sumter Intrastate Air Quality...

  6. 40 CFR 81.52 - Wasatch Front Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.52 Wasatch Front Intrastate Air Quality Control Region. The Wasatch Front Intrastate Air Quality Control Region (Utah) consists of the territorial area encompassed by the boundaries... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Wasatch Front Intrastate Air Quality...

  7. 40 CFR 81.54 - Cook Inlet Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.54 Cook Inlet Intrastate Air Quality Control Region. The Cook Inlet Intrastate Air Quality Control Region (Alaska) consists of the territorial area encompassed by the boundaries... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Cook Inlet Intrastate Air Quality...

  8. 40 CFR 81.95 - Central Florida Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.95 Central Florida Intrastate Air Quality Control Region. The Central Florida Intrastate Air Quality Control Region consists of the territorial area encompassed by the boundaries of the... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Central Florida Intrastate Air Quality...

  9. Quality control for the equipment of Nuclear medicine: experience of the H.U. de la Princesa; Control de calidad del equipamiento en Medicina Nuclear. Experiencia enel H.U. de la Princesa

    Energy Technology Data Exchange (ETDEWEB)

    Espana, M.L.; Gracia, A.; Prieto, C.; Lopez F, P. [Servicio de ProteccionRadiologica. Hospital Universitario de la Princesa C/ Diego de Leon 62, 28006Madrid (Spain)

    1998-12-31

    The quality control of the equipment used in a nuclear medicine service is a fundamental aspect in the Quality Assurance Program that in the present time is starting in our hospital. the objective of this work is to present the internal protocol used, its problematic associated with its starting, and the results obtained in the quality control as of the gamma camera as of the activimeter. In addition to the equipment own to the nuclear medicine service it has been used a Cs-137 source and puppets for several purposes. The results obtained demonstrated the stability of the controlled parameters which has led us to a restating of the established periodicities in our internal protocol, over all for some constancy tests. (Author)

  10. Quality control and quality assurance philosophy introduced in national personnel dosimetry service

    International Nuclear Information System (INIS)

    Trousil, J.; Zelenka, Z.; Kvasnicka, O.

    2008-01-01

    There in National Personnel Dosimetry Service (NPDS) the implementation of the control system to guarantee the credibility of the measured personal dose equivalents results was given on the basis of the international recommendations published by the European Commission and the IAEA and in particular of the decree of the SUJB No. 132/2008 Coll. The quality control and the quality assurance are carried out in all three personal dosimetry services introduced in NPDS: in the film badge, thermoluminescent (TL) and neutron dosimetry. (authors)

  11. Quality control of gamma radiation measuring systems

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The problem of quality control and assurance of gamma radiation measuring systems has been described in detail. The factors deciding of high quality of radiometric measurements as well as statistical testing and calibration of measuring systems have been presented and discussed

  12. Effect of controlled atmosphere on postharvest quality of 'Douradão' peaches

    Directory of Open Access Journals (Sweden)

    Ligia Regina Radomille de Santana

    2011-03-01

    Full Text Available This study was carried out with one of the most important cultivar grown in the State of Sao Paulo, Brazil, which has gained the preference of consumers, due to its sweet taste, intense skin color and large size; however, these fruits are susceptible to chilling injury when cold stored for long periods. The use of controlled atmosphere (CA with elevated CO2 and reduced O2 concentrations prevent the onset of the chilling symptom. Thus, the effect of three different conditions of controlled atmosphere (CA1, CA2, CA3 and Control was evaluated in order to extend the storage life of 'Douradão' peaches. After 14, 21 and 28 days, samples were withdrawn from CA and kept in fresh air at 25 ± 1 °C and 90 ± 5% RH to complete ripening. On the day of removal and after 4 days, were the peaches quality characteristics were evaluated. The results showed that the use of CA during cold storage reduced weight loss and prevented postharvest decay. CA2 and CA3 treatments were effective in keeping good quality of 'Douradão' peaches during 28 days of cold storage, the ripe fruits showed reduced incidence of woolliness, adequate juiciness and flesh firmness. CA1 and Control treatments did not present marketable conditions after 14 days of cold storage.

  13. 40 CFR 81.80 - Las Vegas Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.80 Las Vegas Intrastate Air Quality Control Region. The Las Vegas Intrastate Air Quality Control Region (Nevada) has been revised to consist of the territorial area encompassed by... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Las Vegas Intrastate Air Quality...

  14. Quality assurance and quality control in mammography: A review

    International Nuclear Information System (INIS)

    BenComo, Jose A.

    2000-01-01

    A mammogram is among the most technically demanding radiographic procedures. The early detection of breast cancer relies on the radiologist's ability to perceive subtle changes in the image that are only perceptible with high-quality imaging. Early detection of breast cancer is only as reliable as the mammogram with which a diagnosis is made, and a mammogram is only as accurate as the system that produces it. A quality assurance (QA) program maximizes the likelihood that the mammographic images will provide adequate diagnostic information for the least possible radiation exposure and cost to the patient. The QA program monitors each phase of operation of the imaging facility beginning with the request for an examination and ending with the interpretation of the referring physician and ensures that the imaging equipment used for the examination will yield the information desired. Because image quality is the most important technical aspect of mammography, this review summarizes the most important QA and quality control issues

  15. Internal quality control in serological tests for syphilis.

    OpenAIRE

    Wasley, G D

    1985-01-01

    The importance of syphilis serological tests demands that laboratory reports are reliable. Internal quality control applied to the organisation of a syphilis serology service improves laboratory bench performance and reporting. Described here are internal quality control procedures of a department that serves a genitourinary medicine clinic and conducts 70 000 tests a year to investigate for syphilis.

  16. Introduction to Quality Control in a Compounding Pharmacy.

    Science.gov (United States)

    Allen, Loyd V

    2016-01-01

    A quality-based program is vital in every compounding pharmacy to ensure that each preparation is compounded properly and is stable for its expected duration of use. This article discusses quality control, quality assurance, continuous quality improvement, and also describes the components of an in-house (in-pharmacy) quality program, as well as the role of outside laboratories. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  17. Statistical analysis of quality control of automatic processor

    International Nuclear Information System (INIS)

    Niu Yantao; Zhao Lei; Zhang Wei; Yan Shulin

    2002-01-01

    Objective: To strengthen the scientific management of automatic processor and promote QC, based on analyzing QC management chart for automatic processor by statistical method, evaluating and interpreting the data and trend of the chart. Method: Speed, contrast, minimum density of step wedge of film strip were measured everyday and recorded on the QC chart. Mean (x-bar), standard deviation (s) and range (R) were calculated. The data and the working trend were evaluated and interpreted for management decisions. Results: Using relative frequency distribution curve constructed by measured data, the authors can judge whether it is a symmetric bell-shaped curve or not. If not, it indicates a few extremes overstepping control limits possibly are pulling the curve to the left or right. If it is a normal distribution, standard deviation (s) is observed. When x-bar +- 2s lies in upper and lower control limits of relative performance indexes, it indicates the processor works in stable status in this period. Conclusion: Guided by statistical method, QC work becomes more scientific and quantified. The authors can deepen understanding and application of the trend chart, and improve the quality management to a new step

  18. Quality Assurance and Quality Control in TLD Measurement

    International Nuclear Information System (INIS)

    Bhuiyan, S.I.; Qronfla, M.M.; Abulfaraj, W.H.; Kinsara, A.A.; Taha, T.M.; Molla, N.I.; Elmohr, S.M.

    2008-01-01

    TLD technique characterized by high precision and reproducibility of dose measurement is presented by addressing pre-readout annealing, group sorting, dose evaluation, blind tests, internal dose quality audit and external quality control audits. Two hundred and forty TLD chips were annealed for 1 hour at 4000 degree C followed by 2 h at 1000 degree C. After exposure of 1 mGy from 90 Sr irradiator TLDs were subjected to pre-readout annealing at 1000 degree C, then readout, sorted into groups each with nearly equal sensitivity. Upon repeating the procedures, TLDs having response >3.5% from group mean were dropped to assuring group stability. Effect of pre-readout annealing has been studied. Series of repeated measurements were conducted to stabilize calibration procedures and DCF generation using SSDL level 137 Cs calibrator, dose master, ionization chambers. Performed internal dose quality audits, blind tests and validated by external QC tests with King Abdulaziz City of Science and Technology

  19. Cumulative sum quality control for calibrated breast density measurements

    International Nuclear Information System (INIS)

    Heine, John J.; Cao Ke; Beam, Craig

    2009-01-01

    Purpose: Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach calibrates for interpatient acquisition technique differences. The calibration produces a normalized breast density pixel value scale. The method relies on first generating a baseline (BL) calibration dataset, which required extensive phantom imaging. Standardizing prospective mammograms with calibration data generated in the past could introduce unanticipated error in the standardized output if the calibration dataset is no longer valid. Methods: Sample points from the BL calibration dataset were imaged approximately biweekly over an extended timeframe. These serial samples were used to evaluate the BL dataset reproducibility and quantify the serial calibration accuracy. The cumulative sum (Cusum) quality control method was used to evaluate the serial sampling. Results: There is considerable drift in the serial sample points from the BL calibration dataset that is x-ray beam dependent. Systematic deviation from the BL dataset caused significant calibration errors. This system drift was not captured with routine system quality control measures. Cusum analysis indicated that the drift is a sign of system wear and eventual x-ray tube failure. Conclusions: The BL calibration dataset must be monitored and periodically updated, when necessary, to account for sustained system variations to maintain the calibration accuracy.

  20. Cumulative sum quality control for calibrated breast density measurements

    Energy Technology Data Exchange (ETDEWEB)

    Heine, John J.; Cao Ke; Beam, Craig [Cancer Prevention and Control Division, Moffitt Cancer Center, 12902 Magnolia Drive, Tampa, Florida 33612 (United States); Division of Epidemiology and Biostatistics, School of Public Health, University of Illinois at Chicago, 1603 W. Taylor St., Chicago, Illinois 60612 (United States)

    2009-12-15

    Purpose: Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach calibrates for interpatient acquisition technique differences. The calibration produces a normalized breast density pixel value scale. The method relies on first generating a baseline (BL) calibration dataset, which required extensive phantom imaging. Standardizing prospective mammograms with calibration data generated in the past could introduce unanticipated error in the standardized output if the calibration dataset is no longer valid. Methods: Sample points from the BL calibration dataset were imaged approximately biweekly over an extended timeframe. These serial samples were used to evaluate the BL dataset reproducibility and quantify the serial calibration accuracy. The cumulative sum (Cusum) quality control method was used to evaluate the serial sampling. Results: There is considerable drift in the serial sample points from the BL calibration dataset that is x-ray beam dependent. Systematic deviation from the BL dataset caused significant calibration errors. This system drift was not captured with routine system quality control measures. Cusum analysis indicated that the drift is a sign of system wear and eventual x-ray tube failure. Conclusions: The BL calibration dataset must be monitored and periodically updated, when necessary, to account for sustained system variations to maintain the calibration accuracy.

  1. Quality specification and status of internal quality control of cardiac biomarkers in China from 2011 to 2016.

    Science.gov (United States)

    Li, Tingting; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Yuan, Shuai; Wang, Zhiguo

    2017-09-07

    This study aimed to investigate the status of internal quality control (IQC) for cardiac biomarkers from 2011 to 2016 so that we can have overall knowledge of the precision level of measurements in China and set appropriate precision specifications. Internal quality control data of cardiac biomarkers, including creatinine kinase MB (CK-MB) (μg/L), CK-MB(U/L), myoglobin (Mb), cardiac troponin I (cTnI), cardiac troponin T (cTnT), and homocysteines (HCY), were collected by a web-based external quality assessment (EQA) system. Percentages of laboratories meeting five precision quality specifications for current coefficient of variations (CVs) were calculated. Then, appropriate precision specifications were chosen for these six analytes. Finally, the CVs and IQC practice were further analyzed with different grouping methods. The current CVs remained nearly constant for 6 years. cTnT had the highest pass rates every year against five specifications, whereas HCY had the lowest pass rates. Overall, most analytes had a satisfactory performance (pass rates >80%), except for HCY, if one-third TEa or the minimum specification were employed. When the optimal specification was applied, the performance of most analytes was frustrating (pass rates < 60%) except for cTnT. The appropriate precision specifications of Mb, cTnI, cTnT and HCY were set as current CVs less than 9.20%, 9.90%, 7.50%, 10.54%, 7.63%, and 6.67%, respectively. The data of IQC practices indicated wide variation and substantial progress. The precision performance of cTnT was already satisfying, while the other five analytes, especially HCY, were still frustrating; thus, ongoing investigation and continuous improvement for IQC are still needed. © 2017 Wiley Periodicals, Inc.

  2. Image guided radiotherapy. Quality control of X ray equipment. S.F.P.M. report nr 29

    International Nuclear Information System (INIS)

    Delpon, Gregory; Aubignac, Leone; Bramoulle, Celine; Boutry, Christine; Guerin, Lucie; Lafay, Frederic; Benoit, David; Garcia, Robin; Jaegle, Enric; Vieillevigne, Laure; Dedieu, Veronique; Ferrrer, Ludovic; Guillhem, Marie-Therese; Lacaze, Brigitte; Mazurier, Jocelyne; Simon, Luc

    2014-01-01

    This report presents different X ray imagery systems used for positioning support in external radiation therapy, and installed in treatment rooms. If portal imagery systems and rail-mounted tomodensitometry systems are not addressed in this document, the authors distinguish and describe various embedded systems in which devices are directly mounted on the treatment apparatus (X-Ray Volume Imaging by Elekta, On Board Imager by Varian), peripheral systems which are independent from the machine (Cyberknife by Accuray and Exatrac by BrainLab), MVCT or Mega Voltage Computed Tomography systems (Tomotherapy by Accuray), and MVCBCT or Megavoltage Cone Beam Computed Tomography systems (Artiste by Siemens). After a brief presentation of these systems, the author present various aspects of quality controls (list, periodicity, test tolerance, tested objects), and then more precisely describe the above-mentioned systems. For each of them, the following aspects are addressed: generator, geometry, image quality, dose, environment and safety, gating module, quality controls

  3. Development of the gaharu oil quality control

    International Nuclear Information System (INIS)

    Chong Saw Peng; Mohd Fajri Osman; Shyful Azizi Abdul Rahman; Khairuddin Abdul Rahim; Mat Rasol Awang

    2010-01-01

    Gaharu (Agar wood) is a secondary metabolite produces by the Aquilaria spp. and accumulates in the plant cell in oleoresin form. The essential oil known as gaharu oil can be extracted from this oleoresin gaharu via varies extraction method such as the water distillation, solvent extraction, pressurize extraction and etc. The gaharu oil extracted through different methods will give different fragrances. Besides, different source of materials will also give different in chemical profiles. In gaharu oil trading market, most of the buyers request quality assurance from the gaharu oil manufacturer to assure the gaharu oil purchased meets their standard requirement. Since there is a demand on gaharu oil quality assurance then it become a need to develop the gaharu oil quality control method in order to have a standard quality control of gaharu oil presented in a certificate of analysis and verified by laboratory. (author)

  4. Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Noel S. Ha

    2017-11-01

    Full Text Available Radiopharmaceuticals labeled with short-lived positron-emitting or gamma-emitting isotopes are injected into patients just prior to performing positron emission tomography (PET or single photon emission tomography (SPECT scans, respectively. These imaging modalities are widely used in clinical care, as well as in the development and evaluation of new therapies in clinical research. Prior to injection, these radiopharmaceuticals (tracers must undergo quality control (QC testing to ensure product purity, identity, and safety for human use. Quality tests can be broadly categorized as (i pharmaceutical tests, needed to ensure molecular identity, physiological compatibility and that no microbiological, pyrogenic, chemical, or particulate contamination is present in the final preparation; and (ii radioactive tests, needed to ensure proper dosing and that there are no radiochemical and radionuclidic impurities that could interfere with the biodistribution or imaging. Performing the required QC tests is cumbersome and time-consuming, and requires an array of expensive analytical chemistry equipment and significant dedicated lab space. Calibrations, day of use tests, and documentation create an additional burden. Furthermore, in contrast to ordinary pharmaceuticals, each batch of short-lived radiopharmaceuticals must be manufactured and tested within a short period of time to avoid significant losses due to radioactive decay. To meet these challenges, several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests. More recently, microfluidic quality control systems have been gaining increasing attention due to vastly reduced sample and reagent consumption, shorter analysis times, higher detection sensitivity, increased multiplexing, and reduced instrumentation size. In this review, we describe each of the required QC tests and conventional testing methods, followed by a

  5. Program of TLD audits for quality control in radiotherapy

    International Nuclear Information System (INIS)

    Alvarez, P.; Feld, D.; Gomez, C.; Kessler, C.; Montano, R.G.; Lindner, C.; Peretti, M.; Saravi, M.; Miguez, V.; Paidon, S.; Raslawski, E.

    1998-01-01

    Full text: It is known that a high precision in radiotherapy is essential to ensure a successful radiation treatment. To reach this goal it is necessary to detect and minimise many errors, which can be done through a periodic program of quality control, not only internal checks but also participating in external audits that attempt to control the absorbed dose delivered and detect any source of error, coming from the machine itself or from human mistakes. Under the frame of the International Quality Assurance Network for Dosimetry in Radiotherapy proposed by the International Atomic Energy Agency, a National External Audit Group (EAG) has been created in our country, composed by the Secondary Standard Dosimetry Laboratory (SSDL), 2 Medical Physics and 1 Medical Radiotherapist. The SSDL and one of the Medical Physics belong to the National Atomic Energy Agency, meanwhile the rest of the group belong to the National Pediatric Hospital P rof. J.P.Garrahan . This EAG performs external audits to Radiation Therapy Centres with a thermoluminescence system, which is checked periodically by the IAEA. The audits are performed to the 60 Co γ-ray and high energy X-ray beams that are being used for medical application in the whole country. The SSDL is the responsible of the thermoluminescence measurements; deviation of the absorbed dose determined by the TLD system from the one informed by the Responsible of the Center within the interval ± 5% are considered acceptable while deviations out of this interval require the intervention of the Medical Physic Group and the Radiotherapist in order to determine the cause of the discrepancies. In 1997, 4 audits performed in reference conditions were carried out 68 60 Co units participated in the audits, 61 of them with deviation within the acceptable interval in their first participation, meanwhile 1 got this deviation in repeated audits, after the follow up performed by the Medical Physic Group. Regarding high energy X-ray beams

  6. 40 CFR 75.59 - Certification, quality assurance, and quality control record provisions.

    Science.gov (United States)

    2010-07-01

    ... specified in Equation A-9 in appendix A to this part; (D) Statistical “t” value used in calculations; (E... monitoring systems, the coefficient or “K” factor or other mathematical algorithm used to adjust the... application, or periodically if a different method is used for annual quality assurance testing). (2) For each...

  7. Grape juice quality control by means of {sup 1}H NMR spectroscopy and chemometric analyses

    Energy Technology Data Exchange (ETDEWEB)

    Grandizoli, Caroline Werner Pereira da Silva; Campos, Francinete Ramos; Simonelli, Fabio; Barison, Andersson [Universidade Federal do Paraná (UFPR), Curitiba (Brazil). Departamento de Química

    2014-07-01

    This work shows the application of {sup 1}H NMR spectroscopy and chemometrics for quality control of grape juice. A wide range of quality assurance parameters were assessed by single {sup 1}H NMR experiments acquired directly from juice. The investigation revealed that conditions and time of storage should be revised and indicated on all labels. The sterilization process of homemade grape juices was efficient, making it possible to store them for long periods without additives. Furthermore, chemometric analysis classified the best commercial grape juices to be similar to homemade grape juices, indicating that this approach can be used to determine the authenticity after adulteration. (author)

  8. Quality competition in local hospital markets: some econometric evidence from the period 1982-1988.

    Science.gov (United States)

    Chirikos, T N

    1992-05-01

    This study examines whether American hospitals continued to engage in non-price or quality competition over the recent past as health care markets underwent fundamental structural changes and the economic incentives facing hospital managers were correspondingly altered. It also investigates the degree to which such rivalrous behavior contributes to losses in economic welfare. An econometric model of quality competition is specified that tests, among other things, for the effect of spending by the hospital to enhance the quality of output on annual changes in its share of the local (inpatient) market as well as the effects of competitive conditions in the local market on the annual sum spent on quality enhancement. The model is estimated with panel data on 195 acute care hospitals in the State of Florida for the years 1982-1988. The results suggest that quality competitive behavior continued unabated over this period and that it was stimulated as much by the growth in physician supply and alternative delivery mechanisms as it was by other competing hospitals in the local market. Furthermore, the results show that quality competition yields some inefficiency or waste, but much of it also meets the test of the market.

  9. Quality Control and Quality Assurance of Radiation Oncology

    International Nuclear Information System (INIS)

    Abaza, A.

    2016-01-01

    Radiotherapy (RT) has played important roles in cancer treatment for more than one century. The development of RT techniques allows high-dose irradiation to tumors while reducing the radiation doses delivered to surrounding normal tissues. However, RT is a complex process and involves understanding of the principles of medical physics, radiobiology, radiation safety, dosimetry, radiation treatment planning, simulation and interaction of radiation with other treatment modalities. Each step in the integrated process of RT needs quality control and quality assurance (QA) to prevent errors and to ensure that patients will receive the prescribed treatment correctly. The aim of this study is to help the radio therapists in identifying a system for QA that balances patient safety and quality with available resources. Recent advances in RT focus on the need for a systematic RT QA program that balances patient safety and quality with available resources. It is necessary to develop more formal error mitigation and process analysis methods, such as failure mode and effect analysis (FMEA), to focus available QA resources optimally on the process components. External audit programs are also effective. Additionally, Clinical trial QA has a significant role in enhancing the quality of care. The International Atomic Energy Agency (IAEA) has operated both an on-site and off-site postal dosimetry audit to improve practice and to assure the dose from RT equipment. Both postal dosimetry audit and clinical trial RTQA, especially for advanced technologies, in collaboration with global networks, will serve to enhance patient safety and quality of care

  10. QUALITY IMPROVEMENT USING STATISTICAL PROCESS CONTROL TOOLS IN GLASS BOTTLES MANUFACTURING COMPANY

    Directory of Open Access Journals (Sweden)

    Yonatan Mengesha Awaj

    2013-03-01

    Full Text Available In order to survive in a competitive market, improving quality and productivity of product or process is a must for any company. This study is about to apply the statistical process control (SPC tools in the production processing line and on final product in order to reduce defects by identifying where the highest waste is occur at and to give suggestion for improvement. The approach used in this study is direct observation, thorough examination of production process lines, brain storming session, fishbone diagram, and information has been collected from potential customers and company's workers through interview and questionnaire, Pareto chart/analysis and control chart (p-chart was constructed. It has been found that the company has many problems; specifically there is high rejection or waste in the production processing line. The highest waste occurs in melting process line which causes loss due to trickle and in the forming process line which causes loss due to defective product rejection. The vital few problems were identified, it was found that the blisters, double seam, stone, pressure failure and overweight are the vital few problems. The principal aim of the study is to create awareness to quality team how to use SPC tools in the problem analysis, especially to train quality team on how to held an effective brainstorming session, and exploit these data in cause-and-effect diagram construction, Pareto analysis and control chart construction. The major causes of non-conformities and root causes of the quality problems were specified, and possible remedies were proposed. Although the company has many constraints to implement all suggestion for improvement within short period of time, the company recognized that the suggestion will provide significant productivity improvement in the long run.

  11. Quality control of nuclear medicine instruments, 1991

    International Nuclear Information System (INIS)

    1996-12-01

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of 'Quality Control of Nuclear Medicine Instruments', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems

  12. A quality control program for radiation sources

    International Nuclear Information System (INIS)

    Almeida, C.E. de; Sibata, C.H.; Cecatti, E.R.; Kawakami, N.S.; Alexandre, A.C.; Chiavegatti Junior, M.

    1982-01-01

    An extensive quality control program was established covering the following areas: physical parameters of the therapeutical machines, dosimetric standards, preventive maintenance of radiation sources and measuring instruments. A critical evaluation of this program was done after two years (1977-1979) of routine application and the results will be presented. The fluctuation on physical parameters strongly supports the efforts and cost of a quality control program. This program has certainly improved the accuracy required on the delivery of the prescribed dose for radiotherapy treatment. (Author) [pt

  13. Quality control of nuclear medicine instruments 1991

    International Nuclear Information System (INIS)

    1991-05-01

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of ''Quality Control of Nuclear Medicine Instruments'', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems. Figs and tabs

  14. CASE STUDY ON WATER QUALITY CONTROL IN AN AQUAPONIC SYSTEM

    Directory of Open Access Journals (Sweden)

    Radu Mihai Filep

    2016-07-01

    Full Text Available Aquaponic systems are integrated systems that combine fish farming and different types of plants. It involves a dynamic interaction between fish plants and bacteria. Fish and plants are dependent the equilibrium of dissolved nutrients and water quality. Only by striking a balance between dissolved nutrients and water quality we can achieve a large production of plants and healthy fish. Thus, control of water quality in an aquaponic system is essential in order to obtain performance in raising fish and plants. The experiment was conducted in the laboratory of Fisheries and Aquaculture of the Faculty of Animal Science of the University of Agronomic Sciences and Veterinary Medicine of Bucharest within a period of 30 days. The system used for the experiment was designed and developed in the laboratory mentioned above. The plant used for water treatment in the system was basil (Ocimum basilicum. Fish species grown in the system was culture carp (Cyprinus carpio. Indicators measured to assess water quality in the system were: temperature, pH, dissolved oxygen, total ammonia, nitrites, nitrates and phosphates. The values determined pH 7.4-7.6, dissolved oxygen 8-10 mg / l, NH4 0.05-05 mg/ l, NO2 0.1-3.2 mg / l, NO3 0-80 mg / l, 0.02-0.3 mg, PO4 0.02-0.3 mg/l were not too high. In conclusion it was demonstrated that water quality in the aquaponic system studied is propitious to the growth and welfare of fish the registered values are not to be harmful.

  15. Physical aspects of quality assurance in radiotherapy: A protocol for quality control

    International Nuclear Information System (INIS)

    Aguirre, J.F.; Alfonso-Laguardia, R.; Andreo, P.; Brunetto, M.; Marenco-Zuniga, H.; Gutt, F.; Torres-Calderon, A.

    2000-06-01

    In consistency with the increasing requests from Member States for establishing radiotherapy programmes, an IAEA Technical Co-operation project was initiated in Latin America aimed at improving the physical aspects (as a complement to the clinical issues) of quality assurance in radiotherapy; this ARCAL XXX project (RLA/6/032) was classified as a Model Project of the IAEA. Among the important outcomes of the project were (i) the training of a considerable number of medical physicists in hospitals of the region, (ii) the development of a protocol for quality control procedures, and (iii) the organization of quality audit site visits (to the participant countries) where the implementation in hospitals of the developed quality control procedures is verified. The present publication is the protocol for quality control of the physical aspects of radiotherapy. It contains detailed procedures on what should be measured by a medical physicist in a radiotherapy treatment unit and related equipment, and how this should be made. The latter is made through several appendices, which make the document rather unique. The protocol was developed by medical physicists of the region for the professionals of the region, and it is the first document of this kind ever written in Spanish. A training course was organized in November 1998 (Havana, Cuba) where its practical implementation was taught. There are plans to have this document translated into different languages for the various regions having similar TC projects. (author)

  16. Air Quality and Control Measures Evaluation during the 2014 Youth Olympic Games in Nanjing and its Surrounding Cities

    Directory of Open Access Journals (Sweden)

    Hui Zhao

    2017-06-01

    Full Text Available Air pollution had become a vital concern for the 2014 Youth Olympic Games in Nanjing. In order to control air pollutant emissions and ensure better air quality during the Games, the Nanjing municipal government took a series of aggressive control measures to reduce pollutant emissions in Nanjing and its surrounding cities during the Youth Olympic Games. The Air Quality Index (AQI is an index of air quality which is used to inform the public about levels of air pollution and associated health risks. In this study, we use the AQI and air pollutant concentrations data to evaluate the effectiveness of the implementation of control measures. The results suggest that the emission reduction measures significantly improved air quality in Nanjing. In August 2014, the mean concentrations of PM2.5, PM10, SO2, NO2, CO and O3 were 42.44 μg·m−3, 59.01 μg·m−3, 11.12 μg·m−3, 31.09 μg·m−3, 0.76 mg·m−3 and 38.39 μg·m−3, respectively, and fell by 35.92%, 36.75%, 20.40%, 15.05%, 8.54% and 47.15%, respectively, compared to the prophase mean before the emission reduction. After the emission reduction, the mean concentrations of PM2.5, PM10, SO2, NO2, and O3 increased by 20.81%, 41.84%, 22.84%, 21.16% and 60.93%, respectively, which is due to the cancellation of temporary atmospheric pollution control measures. The air pollutants diurnal variation curve during the emission reduction was lower than the other two periods, except for CO. In addition, the AQI of Nanjing and its surrounding cities showed a downward trend, compared with July 2014. The most of effective method to control air pollution is to implement the measures of regional cooperation and joint defense and control, and reduce local emissions during the polluted period, such as airborne dust, coal-burning, vehicle emissions, mobile sources and industrial production.

  17. Real-Time Scintigraphic Assessment of Intravenous Radium-223 Administration for Quality Control

    Directory of Open Access Journals (Sweden)

    Chadwick L. Wright

    2015-01-01

    Full Text Available Radium-223 (223Ra dichloride is an approved intravenous radiotherapy for patients with osseous metastases from castration-resistant prostate cancer (CRPC. In addition to the therapeutic alpha radiation, there is additional 223Ra radiation generated which produces photons that can be imaged with conventional gamma cameras. No studies have evaluated real-time and quality imaging during intravenous 223Ra administration to verify systemic circulation and exclude 223Ra extravasation at the injection site. A retrospective review was performed for fifteen 223Ra administrations for CRPC patients which were imaged using a large field of view portable gamma camera (LFOVPGC for the purposes of quality control and patient safety. Dynamic imaging of the chest was performed before, during, and after the 223Ra administration to verify systemic circulation, per institutional clinical protocol. Before and after 223Ra administration, a static image was obtained of the intravenous access site. Dynamic imaging of the chest confirmed systemic administration early during the 1-minute injection period for all patients. There were no cases of focal 223Ra extravasation at the site of intravenous access. These results verify that systemic 223Ra administrations can be quantified with real-time imaging using an LFOVPGC. This simple approach can confirm and quantify systemic circulation of 223Ra early during injection and exclude focal extravasation for the purposes of quality control.

  18. Quality control of Ling'ao nuclear power station civil construction

    International Nuclear Information System (INIS)

    Lu Buliang; Ye Changyuan

    2001-01-01

    Based on the quality control model adopted during Ling'ao Nuclear Power Station construction, the author briefly introduces quality control process of some main civil construction activities (reinforced concrete, steel liner, steel works and prestressing force) of nuclear power station, and makes some descriptions on non-conformance control of civil works. These quality control processes described come from the concrete practice during civil construction of Ling'ao Nuclear Power Station, and are based on Daya Bay Nuclear Power Station construction experience

  19. Current quality assurance concepts and considerations for quality control of in-clinic biochemistry testing.

    Science.gov (United States)

    Lester, Sally; Harr, K E; Rishniw, Mark; Pion, Paul

    2013-01-15

    Quality assurance is an implied concept inherent in every consumer's purchase of a product or service. In laboratory testing, quality assurance encompasses preanalytic (sampling, transport, and handling prior to testing), analytic (measurement), and postanalytic (reporting and interpretation) factors. Quality-assurance programs require that procedures are in place to detect errors in all 3 components and that the procedures are characterized by both documentation and correction of errors. There are regulatory bodies that provide mandatory standards for and regulation of human medical laboratories. No such regulations exist for veterinary laboratory testing. The American Society for Veterinary Clinical Pathology (ASVCP) Quality Assurance and Laboratory Standards Committee was formed in 1996 in response to concerns of ASVCP members about quality assurance and quality control in laboratories performing veterinary testing. Guidelines for veterinary laboratory testing have been developed by the ASVCP. The purpose of this report was to provide an overview of selected quality-assurance concepts and to provide recommendations for quality control for in-clinic biochemistry testing in general veterinary practice.

  20. Housing tenancy,data management and quality control

    NARCIS (Netherlands)

    Smeets, J.J.A.M.; Timmermans, H.J.P.

    1993-01-01

    This paper deal s with housing tenancy, data management and quality control. The proposed method is focused on quality characteristics of housing estates in view of rentability risks. It entails a cycle of registration, analysis and implementation of measures. The starting point is the behaviour of

  1. Quality Assurance and Quality Control in Point-of-Care Testing.

    Science.gov (United States)

    Newman, Ashleigh W; Behling-Kelly, Erica

    2016-03-01

    With advancements in the standard of care in veterinary medicine and instrument technology, performing in-house laboratory work on a variety of point-of-care instruments, ranging from glucometers to benchtop chemistry analyzers, has become increasingly commonplace. However, the ability of an instrument to perform a test does not guarantee that those results are accurate. Ensuring that your in-clinic laboratory is providing reliable data requires a comprehensive plan that encompasses both common sense practices aimed at preventing errors at each stage of the testing process, as well as standard operating procedures to validate and monitor analyzer performance. These 2 arms of the plan are known as quality assurance and quality control. Although these concepts are typically out of the comfort zone for veterinarians, just as the thought of business management may deter some veterinarians from practice ownership, it is not beyond the capabilities of veterinarians to learn, understand, and incorporate them into their practice. The objectives of this article are to convey the importance of quality assurance and quality control, walk you through the American Society for Veterinary Clinical Pathology guidelines on this topic, and provide direction to additional resources for further education on this topic, all with the focus on point-of-care testing in the in-clinic laboratory. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Physical and Flavor Quality of Some Potential Varieties of Arabica Coffee in Several Interval Storage Periods

    Directory of Open Access Journals (Sweden)

    Yusianto .

    2006-12-01

    Full Text Available Coffee storage was an active process, where the quality and flavor was depend on the origin, humidity, temperature, period, and ware house condition. The objective of this research was to know quality and flavor of some Arabica coffee varieties in interval of storage periods. The examined coffee varieties were BP 416 A, BP 430 A, BP 432 A, BP 509 A, BP 542 A, P 88, AS 1, S 795, and USDA-762. The treatments were recent harvest, one and two years stored green coffee. The green coffee were wet processed, sun dried, packed in polyethylene bags, one kg/pack and placed in some covered plastic boxes. The boxes were stored in ware house covered with wavy asbes roof and flat asbes ceiling. The green coffee was examined for its moisture content, color, and bulk density. The green coffee was roasted at medium level, and then examined for its the bulk density, yield, volume of swelling, and color of the roasted and powdered. The flavors examination was blind test method. The research showed that storage period significantly influenced the moisture content, color, and bulk density of green coffee, yield, volume of swelling, color of roasted coffee, color, and flavor profile of coffee powder. Those varieties tested showed significantly different on the moisture content, green coffee color, roasted coffee color, coffee powder color, and the profile flavor. The storage period influenced the green coffee color from greenish-gray to yellowish-red. The bulk density of green coffee decreased. The varieties that showed a little color changeduring storage, were BP 430 A,BP 416 A, AS 1, and S 795. One year of storage periode, the green coffee was still had the original color, but after two years, the original color had changed totally. The powder of recent harvest coffee was darker than that of one and two years storage. One year stored coffee had higher quality of aroma, intensity of aroma, quality of flavor, intensity of flavor, acidity, quality of after taste

  3. A system identification approach for developing model predictive controllers of antibody quality attributes in cell culture processes.

    Science.gov (United States)

    Downey, Brandon; Schmitt, John; Beller, Justin; Russell, Brian; Quach, Anthony; Hermann, Elizabeth; Lyon, David; Breit, Jeffrey

    2017-11-01

    As the biopharmaceutical industry evolves to include more diverse protein formats and processes, more robust control of Critical Quality Attributes (CQAs) is needed to maintain processing flexibility without compromising quality. Active control of CQAs has been demonstrated using model predictive control techniques, which allow development of processes which are robust against disturbances associated with raw material variability and other potentially flexible operating conditions. Wide adoption of model predictive control in biopharmaceutical cell culture processes has been hampered, however, in part due to the large amount of data and expertise required to make a predictive model of controlled CQAs, a requirement for model predictive control. Here we developed a highly automated, perfusion apparatus to systematically and efficiently generate predictive models using application of system identification approaches. We successfully created a predictive model of %galactosylation using data obtained by manipulating galactose concentration in the perfusion apparatus in serialized step change experiments. We then demonstrated the use of the model in a model predictive controller in a simulated control scenario to successfully achieve a %galactosylation set point in a simulated fed-batch culture. The automated model identification approach demonstrated here can potentially be generalized to many CQAs, and could be a more efficient, faster, and highly automated alternative to batch experiments for developing predictive models in cell culture processes, and allow the wider adoption of model predictive control in biopharmaceutical processes. © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers Biotechnol. Prog., 33:1647-1661, 2017. © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers.

  4. Controlling chaos in low and high dimensional systems with periodic parametric perturbations

    International Nuclear Information System (INIS)

    Mirus, K.A.; Sprott, J.C.

    1998-06-01

    The effect of applying a periodic perturbation to an accessible parameter of various chaotic systems is examined. Numerical results indicate that perturbation frequencies near the natural frequencies of the unstable periodic orbits of the chaotic systems can result in limit cycles for relatively small perturbations. Such perturbations can also control or significantly reduce the dimension of high-dimensional systems. Initial application to the control of fluctuations in a prototypical magnetic fusion plasma device will be reviewed

  5. MECHANISMS CONTROLLING SURFACE WATER QUALITY IN THE COBRAS RIVER SUB-BASIN, NORTHEASTERN BRAZIL

    Directory of Open Access Journals (Sweden)

    ALEXANDRE DE OLIVEIRA LIMA

    2017-01-01

    Full Text Available Stream water quality is dependent on many factors, including the source and quantity of the streamflow and the types of geology and soil along the path of the stream. This study aims to evaluate the origin and the mechanisms controlling the input of ions that effect surface water quality in the sub-basin of the Rio das Cobras, Rio Grande do Norte state, Northeastern Brazil. Thirteen ponds were identified for study: three in the main river and ten in the tributaries between, thus covering the whole area and lithology of the sub-basin. The samples were collected at two different times (late dry and rainy periods in the hydrological years 2009 and 2010, equating to total of four collection times. We analyzed the spatial and seasonal behavior of water quality in the sub-basin, using Piper diagrams, and analyzed the source of the ions using Guibbs diagram and molar ratios. With respect to ions, we found that water predominate in 82% sodium and 76% bicarbonate water (cations and anions, respectively. The main salinity control mechanism was related to the interaction of the colloidal particles (minerals and organic sediment with the ions dissolved in water. Based on the analysis of nitrates and nitrites there was no evidence of contamination from anthropogenic sources.

  6. Title IV Quality Control Project, Stage II. Management Option II: Delivery System Quality Improvements.

    Science.gov (United States)

    Advanced Technology, Inc., Reston, VA.

    Stage Two of the Title IV Quality Control Project is an integrated study of quality in five related Federal financial aid programs for postsecondary students. Section 1 of the paper establishes a framework for defining quality improvements, in order to identify the types of changes that would tend to improve quality across all facets of the…

  7. 40 CFR 62.7856 - Albuquerque/Bernalillo County Air Quality Control Board.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Board. 62.7856 Section 62.7856 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Albuquerque/Bernalillo County Air Quality Control Board. (a) Identification of Plan. Albuquerque-Bernalillo... County Air Quality Control Board on November 9, 2005. (b) Identification of Sources. The plan applies to...

  8. 40 CFR 81.62 - Northeast Mississippi Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Mississippi Intrastate Air... Air Quality Control Regions § 81.62 Northeast Mississippi Intrastate Air Quality Control Region. The Alabama-Mississippi-Tennessee Interstate Air Quality Control Region has been renamed the Northeast...

  9. 40 CFR 81.216 - Northeast Indiana Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Indiana Intrastate Air... Air Quality Control Regions § 81.216 Northeast Indiana Intrastate Air Quality Control Region. The Northeast Indiana Intrastate Air Quality Control Region (Indiana) consists of the territorial area...

  10. 40 CFR 81.162 - Northeast Plateau Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Plateau Intrastate Air... Air Quality Control Regions § 81.162 Northeast Plateau Intrastate Air Quality Control Region. The Northeast Plateau Intrastate Air Quality Control Region (California) consists of the territorial area...

  11. Initiating a national program in Brazil for the implementation of quality control procedures for radionuclide ''Dose Calibrators and Scintillation Cameras in Nuclear Medicine''. Final report for the period 1987 -1988

    International Nuclear Information System (INIS)

    Mendes, L.

    1988-01-01

    In 1984 the Nuclear Energy Commission of Brazil and the IAEA established a research programme on Nuclear Medicine Quality Control. The programme will be carried out using educational, technical and clinical means to ensure the quality control of the dose calibrators and scintillation cameras

  12. The process of managerial control in quality improvement initiatives.

    Science.gov (United States)

    Slovensky, D J; Fottler, M D

    1994-11-01

    The fundamental intent of strategic management is to position an organization with in its market to exploit organizational competencies and strengths to gain competitive advantage. Competitive advantage may be achieved through such strategies as low cost, high quality, or unique services or products. For health care organizations accredited by the Joint Commission on Accreditation of Healthcare Organizations, continually improving both processes and outcomes of organizational performance--quality improvement--in all operational areas of the organization is a mandated strategy. Defining and measuring quality and controlling the quality improvement strategy remain problematic. The article discusses the nature and processes of managerial control, some potential measures of quality, and related information needs.

  13. standards used for quality control of nuclear fuels

    International Nuclear Information System (INIS)

    Guereli, L; Can, S.

    1997-01-01

    Nuclear fuels and fuel materials are subject to stringent restrictions as to their quality. The standards and regulations that apply vary according to reactor type and country and the standards are stated in the quality assurance documents. The concept of quality assurance has altered the conventional quality control tests and procedures, defining which control tests are to be applied and how. Although most of the tests and measurements allow the determination of tolerances to be decided according to the agreement between the buyer and the seller, exacting procedures apply to which instruments and equipment are used for these tests and measurements, how these instruments are standardized.Detailed explanations of test methods and their documentation is a requirement in all standards. The purpose of this work is to study which standards, tests and measurements apply to the nuclear fuel production. Only the standards that apply to various stages of the nuclear fuel production (powder preparation, pellet production, fuel element and fuel assembly fabrication) are reviewed. Process and documentation control, design and licensing requirements and the frequency of inspections are quality assurance subjects. Some ASTM standards are given as examples

  14. Statistical quality control a loss minimization approach

    CERN Document Server

    Trietsch, Dan

    1999-01-01

    While many books on quality espouse the Taguchi loss function, they do not examine its impact on statistical quality control (SQC). But using the Taguchi loss function sheds new light on questions relating to SQC and calls for some changes. This book covers SQC in a way that conforms with the need to minimize loss. Subjects often not covered elsewhere include: (i) measurements, (ii) determining how many points to sample to obtain reliable control charts (for which purpose a new graphic tool, diffidence charts, is introduced), (iii) the connection between process capability and tolerances, (iv)

  15. Net analyte signal based statistical quality control

    NARCIS (Netherlands)

    Skibsted, E.T.S.; Boelens, H.F.M.; Westerhuis, J.A.; Smilde, A.K.; Broad, N.W.; Rees, D.R.; Witte, D.T.

    2005-01-01

    Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is

  16. Safety of timber : An analysis of quality control options

    NARCIS (Netherlands)

    Kovryga, A.; Stapel, P.; Van de Kuilen, J.W.G.

    2014-01-01

    The quality assurance of timber properties is important for the safety of timber structures. In the current study, the quality control options of timber are analysed under the prism of the different growth regions. Therefore, these options - machine and output control - are simulated in accordance

  17. Control system of digital x-ray systems by quality parameters

    International Nuclear Information System (INIS)

    Balashov, S.V.; Kovalenko, Yu.N.

    2013-01-01

    The paper proposed a control system of X-ray digital equipment on quality indicators. Two basic parameters were determined: image quality and patients' radiation load. A method for monitoring these indicators is proposed. The criterion of equipment suitability is to obtain control digital X-ray images of diagnostically acceptable quality at a fixed low entrance dose in the plane of the digital detector. It is shown that the control system of X-ray digital equipment based on indicators of quality is the most appropriate in situations of deficit of financial resources, since minimizing the costs for the purchase and running of control systems, does not require highly skilled technical personnel, and reduces the duration of the equipment inspection. (authors)

  18. 40 CFR 81.256 - Northeast Iowa Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Iowa Intrastate Air Quality Control Region. 81.256 Section 81.256 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Quality Control Regions § 81.256 Northeast Iowa Intrastate Air Quality Control Region. The Northeast Iowa...

  19. 40 CFR 81.237 - Northeast Georgia Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Georgia Intrastate Air... Air Quality Control Regions § 81.237 Northeast Georgia Intrastate Air Quality Control Region. The Northeast Georgia Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  20. 40 CFR 81.139 - Northeast Arkansas Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Arkansas Intrastate Air... Air Quality Control Regions § 81.139 Northeast Arkansas Intrastate Air Quality Control Region. The Northeast Arkansas Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  1. 40 CFR 81.251 - Northeast Kansas Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Northeast Kansas Intrastate Air... Air Quality Control Regions § 81.251 Northeast Kansas Intrastate Air Quality Control Region. The Northeast Kansas Intrastate Air Quality Control Region consists of the territorial area encompassed by the...

  2. 40 CFR 81.134 - Austin-Waco Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Austin-Waco Intrastate Air Quality Control Region. 81.134 Section 81.134 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Quality Control Regions § 81.134 Austin-Waco Intrastate Air Quality Control Region. The Austin-Waco...

  3. 40 CFR 81.121 - Four Corners Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Four Corners Interstate Air Quality Control Region. 81.121 Section 81.121 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Quality Control Regions § 81.121 Four Corners Interstate Air Quality Control Region. The Four Corners...

  4. 40 CFR 81.93 - Hampton Roads Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Hampton Roads Intrastate Air Quality Control Region. 81.93 Section 81.93 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Quality Control Regions § 81.93 Hampton Roads Intrastate Air Quality Control Region. The Metropolitan...

  5. The Astro-WISE approach to quality control for astronomical data

    NARCIS (Netherlands)

    Mc Farland, John; Helmich, Ewout M.; Valentijn, Edwin A.

    We present a novel approach to quality control during the processing of astronomical data. Quality control in the Astro-WISE Information System is integral to all aspects of data handing and provides transparent access to quality estimators for all stages of data reduction from the raw image to the

  6. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    1997-01-01

    Like the preceding volumes, and met with a lively response, the present volume is collecting contributions stressed on methodology or successful industrial applications. The papers are classified under four main headings: sampling inspection, process quality control, data analysis and process capability studies and finally experimental design.

  7. Periodic boundary conditions and the error-controlled fast multipole method

    Energy Technology Data Exchange (ETDEWEB)

    Kabadshow, Ivo

    2012-08-22

    The simulation of pairwise interactions in huge particle ensembles is a vital issue in scientific research. Especially the calculation of long-range interactions poses limitations to the system size, since these interactions scale quadratically with the number of particles. Fast summation techniques like the Fast Multipole Method (FMM) can help to reduce the complexity to O(N). This work extends the possible range of applications of the FMM to periodic systems in one, two and three dimensions with one unique approach. Together with a tight error control, this contribution enables the simulation of periodic particle systems for different applications without the need to know and tune the FMM specific parameters. The implemented error control scheme automatically optimizes the parameters to obtain an approximation for the minimal runtime for a given energy error bound.

  8. Process-based quality for thermal spray via feedback control

    Science.gov (United States)

    Dykhuizen, R. C.; Neiser, R. A.

    2006-09-01

    Quality control of a thermal spray system manufacturing process is difficult due to the many input variables that need to be controlled. Great care must be taken to ensure that the process remains constant to obtain a consistent quality of the parts. Control is greatly complicated by the fact that measurement of particle velocities and temperatures is a noisy stochastic process. This article illustrates the application of quality control concepts to a wire flame spray process. A central feature of the real-time control system is an automatic feedback control scheme that provides fine adjustments to ensure that uncontrolled variations are accommodated. It is shown how the control vectors can be constructed from simple process maps to independently control particle velocity and temperature. This control scheme is shown to perform well in a real production environment. We also demonstrate that slight variations in the feed wire curvature can greatly influence the process. Finally, the geometry of the spray system and sensor must remain constant for the best reproducibility.

  9. Stabilizing periodic orbits of chaotic systems using fuzzy adaptive sliding mode control

    Energy Technology Data Exchange (ETDEWEB)

    Layeghi, Hamed [Department of Mechanical Engineering, Sharif University of Technology, Center of Excellence in Design, Robotics and Automation, Azadi Avenue, Postal Code 11365-9567 Tehran (Iran, Islamic Republic of)], E-mail: layeghi@mech.sharif.edu; Arjmand, Mehdi Tabe [Department of Mechanical Engineering, Sharif University of Technology, Center of Excellence in Design, Robotics and Automation, Azadi Avenue, Postal Code 11365-9567 Tehran (Iran, Islamic Republic of)], E-mail: arjmand@mech.sharif.edu; Salarieh, Hassan [Department of Mechanical Engineering, Sharif University of Technology, Center of Excellence in Design, Robotics and Automation, Azadi Avenue, Postal Code 11365-9567 Tehran (Iran, Islamic Republic of)], E-mail: salarieh@mech.sharif.edu; Alasty, Aria [Department of Mechanical Engineering, Sharif University of Technology, Center of Excellence in Design, Robotics and Automation, Azadi Avenue, Postal Code 11365-9567 Tehran (Iran, Islamic Republic of)], E-mail: aalasti@sharif.edu

    2008-08-15

    In this paper by using a combination of fuzzy identification and the sliding mode control a fuzzy adaptive sliding mode scheme is designed to stabilize the unstable periodic orbits of chaotic systems. The chaotic system is assumed to have an affine form x{sup (n)} = f(X) + g(X)u where f and g are unknown functions. Using only the input-output data obtained from the underlying dynamical system, two fuzzy systems are constructed for identification of f and g. Two distinct methods are utilized for fuzzy modeling, the least squares and the gradient descent techniques. Based on the estimated fuzzy models, an adaptive controller, which works through the sliding mode control, is designed to make the system track the desired unstable periodic orbits. The stability analysis of the overall closed loop system is presented in the paper and the effectiveness of the proposed adaptive scheme is numerically investigated. As a case of study, modified Duffing system is selected for applying the proposed method to stabilize its 2{pi} and 4{pi} periodic orbits. Simulation results show the high performance of the method for stabilizing the unstable periodic orbits of unknown chaotic systems.

  10. CT dosimetry and quality control of its operation

    International Nuclear Information System (INIS)

    Mechi, Saida

    2011-01-01

    This thesis focuses on the dosimetry of a scanner, quality control of its operations and the development of a protocol. It allowed us the mastery of the art scanner and participation in all quality controls with appropriate ghosts. CT is a radiographic examination sophisticated and accurate, widely used to screen for various diseases, among other cancer. We worked on the dosimetry of a scanner and we have made simulations with a program called Impact that calculates the CT CTDI and the PDL and compared with values displayed on the console. Similarly, the software calculates the absorbed dose and compared with that calculated by Caldose X. This work is complemented by the development of a protocol with the quality control procedures of the image and dosimetry in chronological order.

  11. Periodic synchronization control of discontinuous delayed networks by using extended Filippov-framework.

    Science.gov (United States)

    Cai, Zuowei; Huang, Lihong; Guo, Zhenyuan; Zhang, Lingling; Wan, Xuting

    2015-08-01

    This paper is concerned with the periodic synchronization problem for a general class of delayed neural networks (DNNs) with discontinuous neuron activation. One of the purposes is to analyze the problem of periodic orbits. To do so, we introduce new tools including inequality techniques and Kakutani's fixed point theorem of set-valued maps to derive the existence of periodic solution. Another purpose is to design a switching state-feedback control for realizing global exponential synchronization of the drive-response network system with periodic coefficients. Unlike the previous works on periodic synchronization of neural network, both the neuron activations and controllers in this paper are allowed to be discontinuous. Moreover, owing to the occurrence of delays in neuron signal, the neural network model is described by the functional differential equation. So we introduce extended Filippov-framework to deal with the basic issues of solutions for discontinuous DNNs. Finally, two examples and simulation experiments are given to illustrate the proposed method and main results which have an important instructional significance in the design of periodic synchronized DNNs circuits involving discontinuous or switching factors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Effect of different periods of pre-slaughter stress on the quality of the Nile tilapia meat

    Directory of Open Access Journals (Sweden)

    Pedro Luiz de CASTRO

    2016-01-01

    Full Text Available Abstract The study was carried out with the objective of evaluating the influence of pre-slaughter stress on meat quality of Nile tilapia (O. niloticus for 10 days of storage in ice. 75 whole fish were used eviscerated, with average weight and length of 825.75 ± 101.59 g and 28.25 ± 0.81 cm, respectively. The treatments consisted of time in which the animals underwent pre-slaughter hypoxia, being 0, 3 and 6 minutes. Rigor mortis and muscle pH were assessed besides the application of the Quality Index Method and analysis of total protein and blood glucose. Rigor mortis did not differ among treatments during the storage period, and after three hours all animals were in rigor stage. The muscle pH values varied widely during the study period, observing higher values on the third day of storage. Sensory analysis showed that after 10 days the tilapia from the different treatments did not differ in the evaluated quality parameters similarly, there was no difference regarding the evaluated blood biochemical parameters Thus, hypoxia of 6 minutes pre-slaughter does not influence the rigor mortis, muscle pH, qualitative perception of the meat quality, total protein and blood glucose of Nile tilapia.

  13. Effect of different periods of pre-slaughter stress on the quality of the Nile tilapia meat

    Directory of Open Access Journals (Sweden)

    Pedro Luiz de CASTRO

    Full Text Available Abstract The study was carried out with the objective of evaluating the influence of pre-slaughter stress on meat quality of Nile tilapia (O. niloticus for 10 days of storage in ice. 75 whole fish were used eviscerated, with average weight and length of 825.75 ± 101.59 g and 28.25 ± 0.81 cm, respectively. The treatments consisted of time in which the animals underwent pre-slaughter hypoxia, being 0, 3 and 6 minutes. Rigor mortis and muscle pH were assessed besides the application of the Quality Index Method and analysis of total protein and blood glucose. Rigor mortis did not differ among treatments during the storage period, and after three hours all animals were in rigor stage. The muscle pH values varied widely during the study period, observing higher values on the third day of storage. Sensory analysis showed that after 10 days the tilapia from the different treatments did not differ in the evaluated quality parameters similarly, there was no difference regarding the evaluated blood biochemical parameters Thus, hypoxia of 6 minutes pre-slaughter does not influence the rigor mortis, muscle pH, qualitative perception of the meat quality, total protein and blood glucose of Nile tilapia.

  14. Genetic quality control in mass-reared melon flies

    International Nuclear Information System (INIS)

    Miyatake, T.

    2002-01-01

    Quality control in mass-reared melon flies, Bactrocera cucurbitae, after eradication is discussed, based on the results of artificial selection experiments. First, a brief history of quality control in mass-rearing of insects is described. In practical mass- rearing of melon fly, many traits have already been differentiated between mass-reared and wild flies. These differing traits are reviewed and the factors which caused these differences are considered. It was considered that the differences between wild and mass-reared melon flies depended on the selection pressures from the mass-rearing method. Next, the results of several artificial selection experiments using the melon fly are reviewed. Finally, consideration is given to some correlated responses to artificial selection in mass-rearing. Longevity that is correlated to early fecundity was successfully controlled by artificial selection for reproduction in the mass-rearing system. On the basis of these results, an improved method for quality control in mass-reared melon fly with considerations for quantitative genetics is discussed

  15. 40 CFR 81.176 - San Luis Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false San Luis Intrastate Air Quality Control Region. 81.176 Section 81.176 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Quality Control Regions § 81.176 San Luis Intrastate Air Quality Control Region. The San Luis Intrastate...

  16. 20. Quality assurance and quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Vavrejn, B.

    1989-01-01

    Quality control principles to be applied when taking over and using nuclear medicine instrumentation are given. Such instrumentation includes activity meters, gamma detectors for in vitro measurements (manual or automated instruments), gamma detectors for in vivo measurements (with one or several probes), 'movable' scintigraphs and 'steady' scintigraphs (gamma cameras). (Z.S.)

  17. Direct product quality control for energy efficient climate controlled transport of agro-material

    NARCIS (Netherlands)

    Verdijck, G.J.C.; Preisig, H.A.; Straten, van G.

    2005-01-01

    A (model-based) Product Quality Controller is presented for climate controlled operations involving agro-material, such as storage and transport. This controller belongs to the class of Model Predictive Controllers and fits in a previously developed hierarchical control structure. The new Product

  18. Severe postpartum haemorrhage after vaginal delivery: a statistical process control chart to report seven years of continuous quality improvement.

    Science.gov (United States)

    Dupont, Corinne; Occelli, Pauline; Deneux-Tharaux, Catherine; Touzet, Sandrine; Duclos, Antoine; Bouvier-Colle, Marie-Hélène; Rudigoz, René-Charles; Huissoud, Cyril

    2014-07-01

    Severe postpartum haemorrhage after vaginal delivery: a statistical process control chart to report seven years of continuous quality improvement To use statistical process control charts to describe trends in the prevalence of severe postpartum haemorrhage after vaginal delivery. This assessment was performed 7 years after we initiated a continuous quality improvement programme that began with regular criteria-based audits Observational descriptive study, in a French maternity unit in the Rhône-Alpes region. Quarterly clinical audit meetings to analyse all cases of severe postpartum haemorrhage after vaginal delivery and provide feedback on quality of care with statistical process control tools. The primary outcomes were the prevalence of severe PPH after vaginal delivery and its quarterly monitoring with a control chart. The secondary outcomes included the global quality of care for women with severe postpartum haemorrhage, including the performance rate of each recommended procedure. Differences in these variables between 2005 and 2012 were tested. From 2005 to 2012, the prevalence of severe postpartum haemorrhage declined significantly, from 1.2% to 0.6% of vaginal deliveries (pcontrol limits, that is, been out of statistical control. The proportion of cases that were managed consistently with the guidelines increased for all of their main components. Implementation of continuous quality improvement efforts began seven years ago and used, among other tools, statistical process control charts. During this period, the prevalence of severe postpartum haemorrhage after vaginal delivery has been reduced by 50%. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Food and Nutrition Services Quality Control Management Program.

    Science.gov (United States)

    Wimsatt-Fraim, Teresa S.

    A program was conducted to improve the quality of food service through the training of 44 food and nutrition service employees in a 200-bed hospital. A 12-week quality control program was implemented to address four key areas: food temperatures, food accuracy, food quality, and dietary personnel. Learning strategies, emphasizing critical thinking…

  20. Real time control of the sawtooth period using EC launchers

    International Nuclear Information System (INIS)

    Paley, J I; Felici, F; Coda, S; Goodman, T P; Piras, F

    2009-01-01

    Tokamak plasmas operating at high performance are limited by several MHD instabilities. The sawtooth instability limits the core plasma pressure and can drive the neoclassical tearing mode unstable, but also prevents accumulation of impurities in the core. Electron cyclotron heating and current drive systems can be used to modify the local current profile and therefore tailor the sawtooth period. This paper reports on demonstrations of continuous real time feedback control of the sawtooth period by varying the EC injection angle.

  1. The Periodic Measurement of the Airborne Radioactivity In Controlled Area of KOMAC

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong-Min; Park, Sung-Kyun; Min, Yi-Sub; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Korea Multipurpose Accelerator Complex (KOMAC) to start the performance operation in the second half of 2013, is currently operated in each beamline 20-MeV and 100-MeV. The accelerator operation period is simply divided by three operation cycles which are the maintenance checks period for accelerator device, the performance test period before driving accelerator and the operation period. During this operation period, beam is irradiated to target. At this time, the proton beams collide with the target material and a high dose of radiations such as gamma ray and neutron occurred. Radiation controlled area at the accelerator facility is divided into accelerator tunnel and beam utilization zone. As a result of measuring the airborne radioactivity in the controlled area in accordance with the operating cycle of the proton accelerator KOMAC, It was confirmed that the value of the airborne radioactivity does not significantly differ according to each accelerator operating cycles. And alpha and beta values measured inside the area that workers primarily work is very low indoor radon level than the value of the recommendations in multiple facilities.

  2. Modal Vibration Control in Periodic Time-Varying Structures with Focus on Rotor Blade Systems

    DEFF Research Database (Denmark)

    Christensen, Rene Hardam; Santos, Ilmar

    2004-01-01

    of active modal controllers. The main aim is to reduce vibrations in periodic time-varying structures. Special emphasis is given to vibration control of coupled bladed rotor systems. A state feedback modal control law is developed based on modal analysis in periodic time-varying structures. The first step...... in the procedure is a transformation of the model into a time-invariant modal form by applying the modal matrices, which are also periodic time-variant. Due to coupled rotor and blade motions complex vibration modes occur in the modal transformed state space model. This implies that the modal transformed model...

  3. Quality control of nuclear fuels - technical and economic aspects

    International Nuclear Information System (INIS)

    Strasser, A.A.

    1982-01-01

    The qualification and resolution of questions relating to the cost benefit of quality control are based on the interaction of a broad range of technologies and economics. This paper discusses examples of current areas of interest in quality control, and their relationship to the fuel cycle costs. (orig.)

  4. Neural Network-Based Resistance Spot Welding Control and Quality Prediction

    Energy Technology Data Exchange (ETDEWEB)

    Allen, J.D., Jr.; Ivezic, N.D.; Zacharia, T.

    1999-07-10

    This paper describes the development and evaluation of neural network-based systems for industrial resistance spot welding process control and weld quality assessment. The developed systems utilize recurrent neural networks for process control and both recurrent networks and static networks for quality prediction. The first section describes a system capable of both welding process control and real-time weld quality assessment, The second describes the development and evaluation of a static neural network-based weld quality assessment system that relied on experimental design to limit the influence of environmental variability. Relevant data analysis methods are also discussed. The weld classifier resulting from the analysis successfldly balances predictive power and simplicity of interpretation. The results presented for both systems demonstrate clearly that neural networks can be employed to address two significant problems common to the resistance spot welding industry, control of the process itself, and non-destructive determination of resulting weld quality.

  5. Quality Assurance and Quality Control Practices for Rehabilitation of Sewer and Water Mains

    Science.gov (United States)

    As part of the US Environmental Protection Agency (EPA)’s Aging Water Infrastructure Research Program, several areas of research are being pursued, including a review of quality assurance and quality control (QA/QC) practices and acceptance testing during the installation of reha...

  6. Quality in the fabrication process

    International Nuclear Information System (INIS)

    Romano, A.; Aguirre, F.

    2010-01-01

    Enusa commitment to quality in the manufacture process materializes in the application of the most advanced product quality control technologies such as not-destructive inspection techniques, like artificial vision, X-ray or UT inspection, or process parameter statistical control systems. Quality inspectors are trained and certified by the main National Quality Organizations and receive periodic training under a formal company training program that constantly updates their qualification. Fabrication quality control reliability is based on a strategy that prioritizes redundancy of critical inspection equipment's and inspection personnel knowledge polyvalence. Furthermore, improvement in fabrication quality is obtained by a systematic application of the six sigma methodology where added value is created in projects integrating crosscutting company knowledge, reinforcing the global company vision that the fuel business is based on quality. (Author)

  7. Nutritional intake and overall diet quality of female soccer players before the competition period

    Directory of Open Access Journals (Sweden)

    Daniel dos SANTOS

    Full Text Available ABSTRACT Objective: To assess the dietary intake and overall diet quality of female soccer players before the competitive games. Methods: This descriptive and cross-sectional study included 21 women aged 20.8±4.5 years from a professional soccer team. Their nutritional status and dietary adequacy during the training period, before competition season, were assessed. Dietary intake was assessed by three 24-hour recalls, one food frequency questionnaire, and the Healthy Eating Index, an overall diet quality index based on food group intake. Results: The athletes have shown proper nutritional status, but a diet deficient in energy due largely to low carbohydrate intake. On the other hand, the intakes of protein, fatty acids, and sodium were above the recommended intakes, even for athletes. Diet quality assessment by the Healthy Eating Index - 2010 resulted in a mean score of 54.6 points of a maximum of 100, indicating a need of improving the overall diet quality. Conclusion: The study found that the dietary patterns of female football players were both quantitatively and qualitatively inappropriate. A nutritional intervention is indicated to improve diet quality, with the inclusion of various foods, such as whole grains, fruits, vegetables, dairy products, and better protein quality, along with a reduction in saturated fats, sodium, and added sugar.

  8. Quality control of the 113Sn-113mIn generator

    International Nuclear Information System (INIS)

    Morin Zorilla, J.; Olive, E.; Isaac, M.; Cruz, J.

    1989-01-01

    Methods for quality control of 113 Sn- 113m In generators are compared and recommended the most convenient to applicate in hospitals and in more specialized quality control laboratories. The quality of 113 Sn- 113m In generator produced by POLATOM (Poland) is also evaluated. The product met the requirements of the International Pharmacopeia

  9. Quality control of geological voxel models using experts' gaze

    NARCIS (Netherlands)

    Maanen, P.P. van; Busschers, F.S.; Brouwer, A.M.; Meulen, M.J. van der; Erp, J.B.F. van

    2015-01-01

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12

  10. Quality Control of Geological Voxel Models using Experts' Gaze

    NARCIS (Netherlands)

    van Maanen, Peter-Paul; Busschers, Freek S.; Brouwer, Anne-Marie; van der Meulendijk, Michiel J.; van Erp, Johannes Bernardus Fransiscus

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12

  11. Quality control programme for radiotherapy

    International Nuclear Information System (INIS)

    Campos de Araujo, A.M.; Viegas, C.C.B.; Viamonte, A.M.

    2002-01-01

    A 3 years pilot programme started in January 2000 with 33 philanthropic cancer institutions that provides medical services to 60% of the patients from the national social security system. Brazil has today 161 radiotherapy services (144 operating with megavoltage equipment). These 33 institutions are distributed over 19 Brazilian states. The aim of this programme is: To create conditions to allow the participants to apply the radiotherapy with quality and efficacy; To promote up dating courses for the physicians, physicists and technicians of these 33 Institutions. With the following objectives: To recommend dosimetric and radiological protection procedures in order to guarantee the tumor prescribed dose and safe working conditions; To help in establishing and implementing these procedures. The main activities are: local quality control evaluations, postal TLD audits in reference conditions, postal TLD audits in off axis conditions and training. The local quality control program has already evaluated 22 institutions with 43 machines (25 Co-60 and 18 linear accelerators). In these visits we perform dosimetric, electrical, mechanical and safety tests. As foreseen, we found more problems among the old Co-60 machines i.e., field flatness, size, symmetry and relative output factors; lasers positioning system alignment; optical distance indicator; radiation and light field coincidence; optical and mechanical distance indicators agreement, than among the linear accelerators i.e., field flatness and size; lasers positioning system alignment; tray interlocking and wedge filter factors

  12. Suggestion for improvement of PET quality control tests in Brazil

    International Nuclear Information System (INIS)

    Ferreira, Fernanda C.L.; Magalhaes, Cinthia M.S.; Souza, Divanizia N.

    2009-01-01

    Nowadays nuclear medicine has a considerable importance among the other medical specialties. This medical specialty utilizes high-tech equipment for imaging in the diagnosis, obtaining information on the clinical functionality of organs and systems of the human body through the use of radioisotopes . In view of the importance of guaranteeing the image quality in SPECT and PET systems, enabling patients not repeat exams due to lack of quality control of equipment used in nuclear medicine, this paper aims to present a possible suggestion to update the quality control tests needed for quality assurance of nuclear medicine services. They were considered the requirements of the National Commission of Nuclear Energy (CNEN) and the National Health Surveillance Agency (ANVISA) in Brazil. The minimum requirements to be defined for inclusion of quality control tests on PET in the standard CNEN are extremely important because they will guide the evaluation of PET systems, determining the quality control tests to be performed. And those tests for PET will be a regulatory requirement by the CNEN and ANVISA. As the National Health Surveillance Agency has already publication of RDC 38 with recommendations for services of nuclear medicine. This study will continue with evaluation of PET systems and presenting the tests of quality control with additional objects and simulators to ensure safety in PET systems have not standardized in nuclear medicine services in Brazil. (author)

  13. A quality control manual for oral radiology

    International Nuclear Information System (INIS)

    Peixoto, J.E.; Ferreira, R.S.; Bessa, S.O.; Domingues, C.; Gomes, C.A.; Oliveira, S.L.G.; Ortiz, J.A.P.

    1988-01-01

    A quality control manual for oral radiology is showed. The X-ray equipment used for this activity is described, such as the X-ray tube, collimator. The high tension in X-ray tube, the spectra, the quality and the quantity of radiation and the X-ray intensity are also analysed. (C.G.C.) [pt

  14. A database for the storage of quality control parameters

    International Nuclear Information System (INIS)

    Alves, J.G.; Abrantes, J.N.; Rangel, S.; Santos, L.

    2005-01-01

    Full text: The Individual Monitoring Service at ITN-DPRSN is based on a TLD dosimetry system, that consists of two 6600 Harshaw TLD readers and an the Harshaw 8814 TL card and holder containing two LiF:Mg,Ti (TLD-100) detectors for the evaluation of H p (10) and H p (0.07). A database for the storage of quality control parameters was created using MS Access and is presented in this work. At the moment, the database has a passive role and is used for storage of data and for the retrospective statistical evaluation of important parameters and their evolution with time. lt is regularly fed with the files generated by the NETREMS and/or WINREMS software from Harshaw (presently Thermo Electron Corporation), and allows a quick and user friendly visualization of the data. At present, the information stored therein is: The individual efficiency correction coefficients (ecc) for the card population determined for every TLD card prior to a first use, and their identification as quality control, zero, field and bad cards; The results of the start up daily tests, automatically performed before readouts, e.g. average and relative standard deviation of ten measurements of the temperature, high voltage, ±15 V, D/A reference, ground, internal reference light (RL) source intensity and the photomultiplier tube (PMT) noise; The daily list of readings of the pre-irradiated and unirradiated cards, inter-spaced with field cards at regular intervals, as well as the readings of the PMT noise and the RL intensity, performed at regular intervals during readouts. The average daily readings and their respective standard deviation are also stored; the reader calibration factors (RCF) determined every month at the beginning of a monitoring period; the calibration factor for the 90 Sr-- 90 Y internal irradiator, determined on a monthly basis; the linearity parameters derived from the linear regression curves, performed every month. The insertion of data is determined by each parameter

  15. Internal quality control of RIA with Tonks error calculation method

    International Nuclear Information System (INIS)

    Chen Xiaodong

    1996-01-01

    According to the methodology feature of RIA, an internal quality control chart with Tonks error calculation method which is suitable for RIA is designed. The quality control chart defines the value of the allowance error with normal reference range. The method has the simplicity of its performance and directly perceived through the senses. Taking the example of determining T 3 and T 4 , the calculation of allowance error, drawing of quality control chart and the analysis of result are introduced

  16. Development of Process Control Methodology for Tracking the Quality and Safety of Pain, Agitation, and Sedation Management in Critical Care Units.

    Science.gov (United States)

    Walsh, Timothy S; Kydonaki, Kalliopi; Lee, Robert J; Everingham, Kirsty; Antonelli, Jean; Harkness, Ronald T; Cole, Stephen; Quasim, Tara; Ruddy, James; McDougall, Marcia; Davidson, Alan; Rutherford, John; Richards, Jonathan; Weir, Christopher J

    2016-03-01

    To develop sedation, pain, and agitation quality measures using process control methodology and evaluate their properties in clinical practice. A Sedation Quality Assessment Tool was developed and validated to capture data for 12-hour periods of nursing care. Domains included pain/discomfort and sedation-agitation behaviors; sedative, analgesic, and neuromuscular blocking drug administration; ventilation status; and conditions potentially justifying deep sedation. Predefined sedation-related adverse events were recorded daily. Using an iterative process, algorithms were developed to describe the proportion of care periods with poor limb relaxation, poor ventilator synchronization, unnecessary deep sedation, agitation, and an overall optimum sedation metric. Proportion charts described processes over time (2 monthly intervals) for each ICU. The numbers of patients treated between sedation-related adverse events were described with G charts. Automated algorithms generated charts for 12 months of sequential data. Mean values for each process were calculated, and variation within and between ICUs explored qualitatively. Eight Scottish ICUs over a 12-month period. Mechanically ventilated patients. None. The Sedation Quality Assessment Tool agitation-sedation domains correlated with the Richmond Sedation Agitation Scale score (Spearman ρ = 0.75) and were reliable in clinician-clinician (weighted kappa; κ = 0.66) and clinician-researcher (κ = 0.82) comparisons. The limb movement domain had fair correlation with Behavioral Pain Scale (ρ = 0.24) and was reliable in clinician-clinician (κ = 0.58) and clinician-researcher (κ = 0.45) comparisons. Ventilator synchronization correlated with Behavioral Pain Scale (ρ = 0.54), and reliability in clinician-clinician (κ = 0.29) and clinician-researcher (κ = 0.42) comparisons was fair-moderate. Eight hundred twenty-five patients were enrolled (range, 59-235 across ICUs), providing 12,385 care periods for evaluation (range 655

  17. 32. The scheme of quality control of technical purity aluminum in electrolysis shop of Tajik aluminium Plant in accordance with the requirements of State Standards

    International Nuclear Information System (INIS)

    Ivanov, A.V.

    1993-01-01

    The scheme of quality control of technical purity aluminum in electrolysis shop of Tajik aluminium Plant in accordance with the requirements of State Standards was discussed. The place of sampling or control was defined. The periodicity of sampling or control was defined as well. The characteristics of probe were studied.

  18. 33. The scheme of quality control of silumin in electrolysis shop of Tajik aluminium Plant in accordance with the requirements of State Standard 1521-76

    International Nuclear Information System (INIS)

    Ivanov, A.V.

    1993-01-01

    The scheme of quality control of silumin in electrolysis shop of Tajik aluminium Plant in accordance with the requirements of State Standard 1521-76 was discussed. The place of sampling or control was defined. The periodicity of sampling or control was defined as well. The characteristics of probe were studied.

  19. Quality control of the documentation process in electronic economic activities

    Directory of Open Access Journals (Sweden)

    Krutova A.S.

    2017-06-01

    Full Text Available It is proved that the main tool that will provide adequate information resources e economic activities of social and economic relations are documenting quality control processes as the basis of global information space. Directions problems as formation evaluation information resources in the process of documentation, namely development tools assess the efficiency of the system components – qualitative assessment; development of mathematical modeling tools – quantitative evaluation. A qualitative assessment of electronic documentation of economic activity through exercise performance, efficiency of communication; document management efficiency; effectiveness of flow control operations; relationship management effectiveness. The concept of quality control process documents electronically economic activity to components which include: the level of workflow; forms adequacy of information; consumer quality documents; quality attributes; type of income data; condition monitoring systems; organizational level process documentation; attributes of quality, performance quality consumer; type of management system; type of income data; condition monitoring systems. Grounded components of the control system electronic document subjects of economic activity. Detected components IT-audit management system economic activity: compliance audit; audit of internal control; detailed multilevel analysis; corporate risk assessment methodology. The stages and methods of processing electronic transactions economic activity during condition monitoring of electronic economic activity.

  20. Storing quantum information in XXZ spin rings with periodically time-controlled interactions

    International Nuclear Information System (INIS)

    Giampaolo, S M; Illuminati, F; Mazzarella, G

    2005-01-01

    We introduce a general scheme to realize massive quantum memories in simple systems of interacting qubits. Such systems are described by spin rings with XXZ intersite couplings of suitably time-periodically controlled amplitudes. We show that initially localized excitations undergo perfect periodic revivals, allowing for the simultaneous storage of arbitrary sets of different local states. This novel approach to the problem of storing quantum information hints at a new way to control and suppress the effect of decoherence on a quantum computer realized in a system with nonvanishing interactions between the constituent qubits

  1. Storing quantum information in XXZ spin rings with periodically time-controlled interactions

    Energy Technology Data Exchange (ETDEWEB)

    Giampaolo, S M; Illuminati, F; Mazzarella, G [Dipartimento di Fisica ' E. R. Caianiello' , Universita di Salerno, INFM UdR di Salerno, INFN Sezione di Napoli, Gruppo Collegato di Salerno, Via S. Allende, 84081 Baronissi, SA (Italy)

    2005-10-01

    We introduce a general scheme to realize massive quantum memories in simple systems of interacting qubits. Such systems are described by spin rings with XXZ intersite couplings of suitably time-periodically controlled amplitudes. We show that initially localized excitations undergo perfect periodic revivals, allowing for the simultaneous storage of arbitrary sets of different local states. This novel approach to the problem of storing quantum information hints at a new way to control and suppress the effect of decoherence on a quantum computer realized in a system with nonvanishing interactions between the constituent qubits.

  2. Quality control in 99m technetium radiopharmaceuticals

    International Nuclear Information System (INIS)

    Leon Cabana, Alba

    1994-01-01

    This work means about the quality control in Tc radiopharmaceuticals preparation at hospitalary levels. Several steps must be used in a Nuclear Medicine Laboratory, such as proceeding,radiopharmaceuticals kits preparation, and dispensation materials,glasses,stopper,physical aspects,identification,ph control,storage,and reactif kits

  3. 21 CFR 111.65 - What are the requirements for quality control operations?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What are the requirements for quality control... Process Control System § 111.65 What are the requirements for quality control operations? You must implement quality control operations in your manufacturing, packaging, labeling, and holding operations for...

  4. Association of adherence to epilepsy quality standards with seizure control.

    Science.gov (United States)

    Moura, Lidia M V R; Mendez, Diego Yacaman; Jesus, Jonathan De; Andrade, Rogger A; Weissman, Joel S; Vickrey, Barbara G; Hoch, Daniel B

    2015-11-01

    We assessed the relationship between adherence to epilepsy quality measures (EQM) and seizure control over 2-3 years in a retrospective cohort study. 6150 patients were identified at two large academic medical centers with a primary or secondary diagnosis of epilepsy, were 18-85 years old and seen in outpatient general neurology or epilepsy units between June 2011 and May 2014. Patients were included if: their initial visit was between June 2011 and June 2012, treatment was with ≥1 anti-seizure drug, there was ≥1 visit per year during the timeframe, and seizure frequency was documented at initial and final visits, yielding 162 patients/1055 visits from which socio-demographic, clinical and care quality data were abstracted. Quality care was assessed as (1) percent adherence to up to 8 eligible EQM, and (2) defect-free care (DFC: adherence to all eligible EQM). Seizure control (SC) was defined as ≥50% reduction in average seizures/month between initial and final visits. Chi-square and t-test compared care quality with seizure control. Logistic regression was used to assess the relationships between SC, quality of care and subspecialist involvement. Care quality, reflected by documentation of seizure frequency, addressing therapeutic interventions, and referral to a comprehensive epilepsy center, all exceeded 80% adherence. Care quality as reflected by documentation of seizure type, etiology or syndrome; assessment of side effects, counseling about epilepsy safety and women's issues, and screening for psychiatric disorders ranged from 40 to 57%. Mean EQM adherence across all applicable measures was associated with greater seizure control (p=0.0098). DFC was low (=8%) and did not covary with seizure control (p=0.55). The SC and non-SC groups only differed on epilepsy etiology (p=0.04). Exploratory analysis showed that mean quality scores are associated with seizure control (OR=4.9 [1.3-18.5], p=0.017) while controlling for the effect of subspecialty involvement

  5. Possible approaches to fast quality control of IFE targets

    International Nuclear Information System (INIS)

    Koresheva, E.R.; Nikitenko, A.I.; Aleksandrova, I.V.; Bazdenkov, S.V.; Belolipetskiy, A.A.; Chtcherbakov, V.I.; Osipov, I.E.

    2006-01-01

    In recent years, research into the development of reliable methods and techniques for characterization and quality control of ICF/IFE targets has been carried out very actively. This is motivated by the need to provide the means for precise and accurate knowledge of cryogenic target parameters. On the other hand, particular emphasis should be paid to the fact that fuelling of a commercial power plant requires ∼6 targets each second. This indicates that the development of fast quality control techniques is of critical importance as well. Therefore, in this report we discuss the issues underlying the construction of different algorithms for characterization and quality control of ICF/IFE targets. Among them are: (a) algorithm banks and their structure, (b) algorithm testing, (c) target reconstruction experiments. The algorithm bank incorporates the algorithms for two stages of target production: the stage of fuel layering technique development (motionless target) and the stage of cryogenic target delivery (injected target). In the first case an inverse algorithm for individual target characterization (3D target reconstruction) and two threshold algorithms for fast control of target quality are presented. They are based on tomographic information processing methods. Experimentally, tomographic data acquisition is carried out by a hundred projections microtomograph. The spatial resolution of the optical system of the microtomograph is 1 μm for 490 nm wavelength, the accuracy of target angular positioning is ±1.5-2.5 min. In the second case we describe the algorithm based on Fourier transform holography for ultra fast target characterization during its injection. The performed computer experiments have demonstrated much promise of this approach in the following directions: recognition of the target imperfections in both low- and high- harmonics; quality control of both a single target and a target batch; simultaneous control of both an injected target quality and

  6. 21 CFR 866.2480 - Quality control kit for culture media.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality control kit for culture media. 866.2480... control kit for culture media. (a) Identification. A quality control kit for culture media is a device...-dried, viable microorganism, intended for medical purposes to determine if a given culture medium is...

  7. Informatization of items quality control for NI in nuclear power plant

    International Nuclear Information System (INIS)

    Zhang Jiankui; Zang Baiqi

    2010-01-01

    Design ideas, implementation methods and some key techniques for item quality control of NI in nuclear power plant are illustrated in this article according to item quality management mode. The item quality control method can improve the quality of NI, ensure the safety and lower the construction and operation cost of nuclear power plant. (authors)

  8. Ways to control quality of electric equipment in the coal industry

    Energy Technology Data Exchange (ETDEWEB)

    Shipilov, A.D.; Nabokov, E.P.

    1982-01-01

    A structure is proposed for organization in the coal industry of a permanent service for controlling quality of electrical engineering equipment. A form was developed for introduction of recommendations to improve quality. Methods are suggested for evaluating the quality level as applied to specific tasks of controlling quality of the electrical equipment used in mining.

  9. Quality Risk Management: Putting GMP Controls First.

    Science.gov (United States)

    O'Donnell, Kevin; Greene, Anne; Zwitkovits, Michael; Calnan, Nuala

    2012-01-01

    This paper presents a practical way in which current approaches to quality risk management (QRM) may be improved, such that they better support qualification, validation programs, and change control proposals at manufacturing sites. The paper is focused on the treatment of good manufacturing practice (GMP) controls during QRM exercises. It specifically addresses why it is important to evaluate and classify such controls in terms of how they affect the severity, probability of occurrence, and detection ratings that may be assigned to potential failure modes or negative events. It also presents a QRM process that is designed to directly link the outputs of risk assessments and risk control activities with qualification and validation protocols in the GMP environment. This paper concerns the need for improvement in the use of risk-based principles and tools when working to ensure that the manufacturing processes used to produce medicines, and their related equipment, are appropriate. Manufacturing processes need to be validated (or proven) to demonstrate that they can produce a medicine of the required quality. The items of equipment used in such processes need to be qualified, in order to prove that they are fit for their intended use. Quality risk management (QRM) tools can be used to support such qualification and validation activities, but their use should be science-based and subject to as little subjectivity and uncertainty as possible. When changes are proposed to manufacturing processes, equipment, or related activities, they also need careful evaluation to ensure that any risks present are managed effectively. This paper presents a practical approach to how QRM may be improved so that it better supports qualification, validation programs, and change control proposals in a more scientific way. This improved approach is based on the treatment of what are called good manufacturing process (GMP) controls during those QRM exercises. A GMP control can be considered

  10. Minimal requirements for quality controls in radiotherapy with external beams

    International Nuclear Information System (INIS)

    1999-01-01

    Physical dosimetric guidelines have been developed by the Italian National Institute of Health study group on quality assurance in radiotherapy to define protocols for quality controls in external beam radiotherapy. While the document does not determine strict rules or firm recommendations, it suggests minimal requirements for quality controls necessary to guarantee an adequate degree of accuracy in external beam radiotherapy [it

  11. Improving Code Quality of the Compact Muon Solenoid Electromagnetic Calorimeter Control Software to Increase System Maintainability

    CERN Multimedia

    Holme, Oliver; Dissertori, Günther; Djambazov, Lubomir; Lustermann, Werner; Zelepoukine, Serguei

    2013-01-01

    The Detector Control System (DCS) software of the Electromagnetic Calorimeter (ECAL) of the Compact Muon Solenoid (CMS) experiment at CERN is designed primarily to enable safe and efficient operation of the detector during Large Hadron Collider (LHC) data-taking periods. Through a manual analysis of the code and the adoption of ConQAT [1], a software quality assessment toolkit, the CMS ECAL DCS team has made significant progress in reducing complexity and improving code quality, with observable results in terms of a reduction in the effort dedicated to software maintenance. This paper explains the methodology followed, including the motivation to adopt ConQAT, the specific details of how this toolkit was used and the outcomes that have been achieved. [1] ConQAT, Continuous Quality Assessment Toolkit; https://www.conqat.org/

  12. Quality control and quality standards for the production of bone allografts in China

    International Nuclear Information System (INIS)

    Sun Shiquan; Li Youchen

    1999-01-01

    There is a rapid progress of tissue banking especially Bone Banking in China, In order to strengthen the control on medical devices, Ministry of Public Health (MPH) issued the 'Regulation on Supervision of Critical Medical Devices, MPH Decree No. 54' in 1997. The SPTB was requested to submit new application for the approval of production and providing of tissue allografts. The needed documents are clinical reports, package insert, quality standards of product, Quality System Regulation (QSR) and audit report. Quality System Regulation document adopted the GMP standard for medical devices of FDA, US (21 CFR 620-1997). SPTB will amend the existed Quality Manual to suit the requirement of QSR. Referring to the AATB Standards, SPTB established 'Technical Standards' for Tissue Banking and was approved by the local government, which will be the supplement of the submitted QSR document. Considering the need of market control, MPH requested to submit a 'Quality Standard of Product' and the method of inspection. SPTB has completed such standards for final inspection of bone products, which includes the test for residual water, microbiology, bone species, colour and structure. In addition, the Tissue Bank has completed standards for in process inspection, which includes residual blood, radiation sterilization, initial bioburden, package leakage and biomechanics. In-process inspection is important for the control of non-conforming final products to assure the safety and efficacy of bone grafts. Methods of in process inspection and final inspection are described and discussed in this paper

  13. Dicyclopentadiene Hydrogenation in Trickle Bed Reactor under Forced Periodic Control

    Czech Academy of Sciences Publication Activity Database

    Skála, D.; Hanika, Jiří

    2008-01-01

    Roč. 62, č. 2 (2008), s. 215-218 ISSN 1336-7242 R&D Projects: GA MPO(CZ) FT-TA/039 Institutional research plan: CEZ:AV0Z40720504 Keywords : periodic control * trickle -bed reactor * dicyclopentadiene Subject RIV: CI - Industrial Chemistry, Chemical Engineering

  14. Status and future trends of Analytical Quality Control Services

    International Nuclear Information System (INIS)

    LaBrecque, J.J.; Schelenz, R.; Hardy, E.P.

    1987-07-01

    This report reviews the present Analytical Quality Control Services (AQCS) programme components in the light of the needs of IAEA Member States for analytical reference materials and intercomparisons, provides guidelines for the direction which the programme should take in the future and identifies the type of Analytical Quality Control Services most urgently required by the Member States

  15. Periodic feedback stabilization for linear periodic evolution equations

    CERN Document Server

    Wang, Gengsheng

    2016-01-01

    This book introduces a number of recent advances regarding periodic feedback stabilization for linear and time periodic evolution equations. First, it presents selected connections between linear quadratic optimal control theory and feedback stabilization theory for linear periodic evolution equations. Secondly, it identifies several criteria for the periodic feedback stabilization from the perspective of geometry, algebra and analyses respectively. Next, it describes several ways to design periodic feedback laws. Lastly, the book introduces readers to key methods for designing the control machines. Given its coverage and scope, it offers a helpful guide for graduate students and researchers in the areas of control theory and applied mathematics.

  16. Six Sigma Quality Management System and Design of Risk-based Statistical Quality Control.

    Science.gov (United States)

    Westgard, James O; Westgard, Sten A

    2017-03-01

    Six sigma concepts provide a quality management system (QMS) with many useful tools for managing quality in medical laboratories. This Six Sigma QMS is driven by the quality required for the intended use of a test. The most useful form for this quality requirement is the allowable total error. Calculation of a sigma-metric provides the best predictor of risk for an analytical examination process, as well as a design parameter for selecting the statistical quality control (SQC) procedure necessary to detect medically important errors. Simple point estimates of sigma at medical decision concentrations are sufficient for laboratory applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. The application of statistical process control in linac quality assurance

    International Nuclear Information System (INIS)

    Li Dingyu; Dai Jianrong

    2009-01-01

    Objective: To improving linac quality assurance (QA) program with statistical process control (SPC) method. Methods: SPC is applied to set the control limit of QA data, draw charts and differentiate the random and systematic errors. A SPC quality assurance software named QA M ANAGER has been developed by VB programming for clinical use. Two clinical cases are analyzed with SPC to study daily output QA of a 6MV photon beam. Results: In the clinical case, the SPC is able to identify the systematic errors. Conclusion: The SPC application may be assistant to detect systematic errors in linac quality assurance thus it alarms the abnormal trend to eliminate the systematic errors and improves quality control. (authors)

  18. New approach for quality control in manufacturing process

    Science.gov (United States)

    Hanzah, Muhammad Radhi bin; Rahim, Wan Mohd Faizal Wan Abd; Khor, C. Y.; Ishak, Muhammad Ikman; Rosli, M. U.; Jamalludin, Mohd Riduan; Zakaria, M. S.; Nawi, M. A. M.

    2017-09-01

    This study was regulated exclusively in view of theoretical aspect and further research should be done to demonstrate it in the genuine circumstance. The structure of this investigation including two industrial visits, i.e. interviews and meeting with approved staff from each organization agents. This review is cut up into two sections. Aside from the perception, little gatherings with the staffs from both organizations are held. With the subtle elements, the review is begun up. The aim of the study is characterized as to enhance the assessment strategy at quality control station to minimize defect outflow to the following client. This is to investigate the underlying factor in ebb and flow quality control framework so that another strategy to enhance quality control framework can implemented. Quality is a basic characteristic to be instated so that the end goal to fulfill clients' need is achieved. After a long hypothetical review is made, the best answer for be actualized at QG station to beat defects outflow to the following customer is by photoelectric sensor. It is reasonable, simple to keep up and has a high affectability to identify the defective items at the QG station.

  19. Quality and Control of Water Vapor Winds

    Science.gov (United States)

    Jedlovec, Gary J.; Atkinson, Robert J.

    1996-01-01

    Water vapor imagery from the geostationary satellites such as GOES, Meteosat, and GMS provides synoptic views of dynamical events on a continual basis. Because the imagery represents a non-linear combination of mid- and upper-tropospheric thermodynamic parameters (three-dimensional variations in temperature and humidity), video loops of these image products provide enlightening views of regional flow fields, the movement of tropical and extratropical storm systems, the transfer of moisture between hemispheres and from the tropics to the mid- latitudes, and the dominance of high pressure systems over particular regions of the Earth. Despite the obvious larger scale features, the water vapor imagery contains significant image variability down to the single 8 km GOES pixel. These features can be quantitatively identified and tracked from one time to the next using various image processing techniques. Merrill et al. (1991), Hayden and Schmidt (1992), and Laurent (1993) have documented the operational procedures and capabilities of NOAA and ESOC to produce cloud and water vapor winds. These techniques employ standard correlation and template matching approaches to wind tracking and use qualitative and quantitative procedures to eliminate bad wind vectors from the wind data set. Techniques have also been developed to improve the quality of the operational winds though robust editing procedures (Hayden and Veldon 1991). These quality and control approaches have limitations, are often subjective, and constrain wind variability to be consistent with model derived wind fields. This paper describes research focused on the refinement of objective quality and control parameters for water vapor wind vector data sets. New quality and control measures are developed and employed to provide a more robust wind data set for climate analysis, data assimilation studies, as well as operational weather forecasting. The parameters are applicable to cloud-tracked winds as well with minor

  20. ChronQC: a quality control monitoring system for clinical next generation sequencing.

    Science.gov (United States)

    Tawari, Nilesh R; Seow, Justine Jia Wen; Perumal, Dharuman; Ow, Jack L; Ang, Shimin; Devasia, Arun George; Ng, Pauline C

    2018-05-15

    ChronQC is a quality control (QC) tracking system for clinical implementation of next-generation sequencing (NGS). ChronQC generates time series plots for various QC metrics to allow comparison of current runs to historical runs. ChronQC has multiple features for tracking QC data including Westgard rules for clinical validity, laboratory-defined thresholds and historical observations within a specified time period. Users can record their notes and corrective actions directly onto the plots for long-term recordkeeping. ChronQC facilitates regular monitoring of clinical NGS to enable adherence to high quality clinical standards. ChronQC is freely available on GitHub (https://github.com/nilesh-tawari/ChronQC), Docker (https://hub.docker.com/r/nileshtawari/chronqc/) and the Python Package Index. ChronQC is implemented in Python and runs on all common operating systems (Windows, Linux and Mac OS X). tawari.nilesh@gmail.com or pauline.c.ng@gmail.com. Supplementary data are available at Bioinformatics online.

  1. Pharmaceutical quality by design: product and process development, understanding, and control.

    Science.gov (United States)

    Yu, Lawrence X

    2008-04-01

    The purpose of this paper is to discuss the pharmaceutical Quality by Design (QbD) and describe how it can be used to ensure pharmaceutical quality. The QbD was described and some of its elements identified. Process parameters and quality attributes were identified for each unit operation during manufacture of solid oral dosage forms. The use of QbD was contrasted with the evaluation of product quality by testing alone. The QbD is a systemic approach to pharmaceutical development. It means designing and developing formulations and manufacturing processes to ensure predefined product quality. Some of the QbD elements include: Defining target product quality profile; Designing product and manufacturing processes; Identifying critical quality attributes, process parameters, and sources of variability; Controlling manufacturing processes to produce consistent quality over time. Using QbD, pharmaceutical quality is assured by understanding and controlling formulation and manufacturing variables. Product testing confirms the product quality. Implementation of QbD will enable transformation of the chemistry, manufacturing, and controls (CMC) review of abbreviated new drug applications (ANDAs) into a science-based pharmaceutical quality assessment.

  2. Periodic limb movements during sleep are associated with a lower quality of life in children with monosymptomatic nocturnal enuresis.

    Science.gov (United States)

    Van Herzeele, Charlotte; Dhondt, Karlien; Roels, Sanne Patrick; Raes, Ann; Groen, Luitzen-Albert; Hoebeke, Piet; Vande Walle, Johan

    2015-07-01

    The study investigates whether cortical arousals and periodic limb movements during sleep are related to daytime psychological functioning in children with monosymptomatic nocturnal enuresis with associated nocturnal polyuria. Psychological functioning is evaluated on five domains: attention deficit hyperactivity disorder-inattentive problems, quality of life, internalizing problems, externalizing problems, and executive functioning. This multi-informant (parents, teachers, and children) and multi-method study included overnight video-polysomnography, questionnaires, and neuropsychological testing. Thirty children (7 girls) 6 to 16 years (mean 10.43 years, SD 3.08) were selected in a tertiary enuresis center. A high index of periodic limb movements during sleep was associated with a lower quality of life, according to the child. No significant correlations were found with attention deficit hyperactivity disorder-inattentive problems, internalizing problems, externalizing problems, and executive functioning. This study clarifies the relationship between sleep parameters and psychological functioning of the children with monosymptomatic nocturnal enuresis and associated nocturnal polyuria according to the child, the parents, and the teachers. Periodic limb movements during sleep are associated with a lower quality of life of the child.

  3. Spatial Domain Adaptive Control of Nonlinear Rotary Systems Subject to Spatially Periodic Disturbances

    Directory of Open Access Journals (Sweden)

    Yen-Hsiu Yang

    2012-01-01

    Full Text Available We propose a generic spatial domain control scheme for a class of nonlinear rotary systems of variable speeds and subject to spatially periodic disturbances. The nonlinear model of the rotary system in time domain is transformed into one in spatial domain employing a coordinate transformation with respect to angular displacement. Under the circumstances that measurement of the system states is not available, a nonlinear state observer is established for providing the estimated states. A two-degree-of-freedom spatial domain control configuration is then proposed to stabilize the system and improve the tracking performance. The first control module applies adaptive backstepping with projected parametric update and concentrates on robust stabilization of the closed-loop system. The second control module introduces an internal model of the periodic disturbances cascaded with a loop-shaping filter, which not only further reduces the tracking error but also improves parametric adaptation. The overall spatial domain output feedback adaptive control system is robust to model uncertainties and state estimated error and capable of rejecting spatially periodic disturbances under varying system speeds. Stability proof of the overall system is given. A design example with simulation demonstrates the applicability of the proposed design.

  4. Quality control of injection moulded micro mechanical parts

    DEFF Research Database (Denmark)

    Gasparin, Stefania; Tosello, Guido; Hansen, Hans Nørgaard

    2009-01-01

    Quality control of micro components is an increasing challenge. Smaller mechanical parts are characterized by smaller tolerance to be verified. This paper focuses on the dimensional verification of micro injection moulded components selected from an industrial application. These parts are measured...... using an Optical Coordinate Measuring Machine (OCMM), which guarantees fast surface scans suitable for in line quality control. The uncertainty assessment of the measurements is calculated following the substitution method. To investigate the influence parameters in optical coordinate metrology two...

  5. H-infinity Control of Linear Systems with Almost Periodic Inputs

    DEFF Research Database (Denmark)

    Larsen, Mikael

    1996-01-01

    In this paper we consider the class of linear, infinitedimensional systems with bounded input and output operators. Wederive and QTR H-infinity type result, formulated for thecase where the input signals are almost periodic in a generalizedsense. Control probelms, for which this result is relevant...

  6. Frequency Adaptive Control Technique for Periodic Runout and Wobble Cancellation in Optical Disk Drives

    Directory of Open Access Journals (Sweden)

    Yee-Pien Yang

    2006-10-01

    Full Text Available Periodic disturbance occurs in various applications on the control of the rotational mechanical systems. For optical disk drives, the spirally shaped tracks are usually not perfectly circular and the assembly of the disk and spindle motor is unavoidably eccentric. The resulting periodic disturbance is, therefore, synchronous with the disk rotation, and becomes particularly noticeable for the track following and focusing servo system. This paper applies a novel adaptive controller, namely Frequency Adaptive Control Technique (FACT, for rejecting the periodic runout and wobble effects in the optical disk drive with dual actuators. The control objective is to attenuate adaptively the specific frequency contents of periodic disturbances without amplifying its rest harmonics. FACT is implemented in a plug-in manner and provides a suitable framework for periodic disturbance rejection in the cases where the fundamental frequencies of the disturbance are alterable. It is shown that the convergence property of parameters in the proposed adaptive algorithm is exponentially stable. It is applicable to both the spindle modes of constant linear velocity (CLV and constant angular velocity (CAV for various operation speeds. The experiments showed that the proposed FACT has successful improvement on the tracking and focusing performance of the CD-ROM, and is extended to various compact disk drives.

  7. [Quality process control system of Chinese medicine preparation based on "holistic view"].

    Science.gov (United States)

    Wang, Ya-Qi; Jiao, Jiao-Jiao; Wu, Zhen-Feng; Zheng, Qin; Yang, Ming

    2018-01-01

    "High quality, safety and effectiveness" are the primary principles for the pharmaceutical research and development process in China. The quality of products relies not only on the inspection method, but also on the design and development, process control and standardized management. The quality depends on the process control level. In this paper, the history and current development of quality control of traditional Chinese medicine (TCM) preparations are reviewed systematically. Based on the development model of international drug quality control and the misunderstanding of quality control of TCM preparations, the reasons for impacting the homogeneity of TCM preparations are analyzed and summarized. According to TCM characteristics, efforts were made to control the diversity of TCM, make "unstable" TCM into "stable" Chinese patent medicines, put forward the concepts of "holistic view" and "QbD (quality by design)", so as to create the "holistic, modular, data, standardized" model as the core of TCM preparation quality process control model. Scientific studies shall conform to the actual production of TCM preparations, and be conducive to supporting advanced equipment and technology upgrade, thoroughly applying the scientific research achievements in Chinese patent medicines, and promoting the cluster application and transformation application of TCM pharmaceutical technology, so as to improve the quality and effectiveness of the TCM industry and realize the green development. Copyright© by the Chinese Pharmaceutical Association.

  8. 40 CFR 81.38 - Metropolitan Houston-Galveston Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Metropolitan Houston-Galveston... Designation of Air Quality Control Regions § 81.38 Metropolitan Houston-Galveston Intrastate Air Quality Control Region. The Metropolitan Houston-Galveston Intrastate Air Quality Control Region (Texas) has been...

  9. Managing Air Quality - Multi-Pollutant Planning and Control

    Science.gov (United States)

    Describes how planning controls for multiple pollutants at the same time can save money and time and achieve significant benefits, and how control strategies can address both climate change and air quality.

  10. Randomised controlled trial of the effectiveness of using foot reflexology to improve quality of sleep amongst Taiwanese postpartum women.

    Science.gov (United States)

    Li, Chia-Yen; Chen, Su-Chiu; Li, Chung-Yi; Gau, Meei-Ling; Huang, Chiu-Mieh

    2011-04-01

    to examine the effectiveness of using foot reflexology to improve sleep quality in postpartum women. randomised controlled trial, conducted at two postpartum centres in northern Taiwan. 65 postpartum women reporting poor quality of sleep were recruited from July 2007 to December 2007. participants were assigned randomly to either an intervention or a control group. Participants in both groups received the same care except for reflexology therapy. The intervention group received a single 30-minute foot reflexology session at the same time each evening for five consecutive days. Sessions were administered by a certified nurse reflexologist. MEASURES AND FINDINGS: the outcome measure was the Pittsburgh sleep quality index (PSQI), and this was performed at baseline and post test. Mean PQSI scores for both groups declined over time between baseline and post test. Using a generalised estimation equation to control several confounding variables, the changes in mean PSQI were found to be significantly lower in the intervention group (β=-2.24, standard error=0.38, pfoot reflexology in the postnatal period significantly improved the quality of sleep. midwives should evaluate maternal sleep quality and design early intervention programmes to improve quality of sleep in order to increase maternal biopsychosocial well-being. Midwives interested in complementary therapies should be encouraged to obtain training in reflexology and to apply it in clinical settings if it is allowed. Copyright © 2009 Elsevier Ltd. All rights reserved.

  11. Application of improved quality control technology to pressure vessels

    International Nuclear Information System (INIS)

    Kriedt, F.

    1985-01-01

    Within the last decade, ASME Boiler and Pressure Vessel Code Section VIII-1 instituted requirements for a formal written quality control system. The results, good and bad, of this requirement are discussed. The effects are far reaching from a national economic standpoint. Quality control technology has improved. These improvements are discussed and compared to existing requirements of the CODE. Recommended improvements are suggested

  12. Perioperative Care and the Importance of Continuous Quality Improvement—A Controlled Intervention Study in Three Tanzanian Hospitals

    Science.gov (United States)

    Mtatifikolo, Ferdinand; Ngoli, Baltazar; Neuner, Bruno; Wernecke, Klaus–Dieter; Spies, Claudia

    2015-01-01

    Introduction Surgical services are increasingly seen to reduce death and disability in Sub-Saharan Africa, where hospital-based mortality remains alarmingly high. This study explores two implementation approaches to improve the quality of perioperative care in a Tanzanian hospital. Effects were compared to a control group of two other hospitals in the region without intervention. Methods All hospitals conducted quality assessments with a Hospital Performance Assessment Tool. Changes in immediate outcome indicators after one and two years were compared to final outcome indicators such as Anaesthetic Complication Rate and Surgical Case Fatality Rate. Results Immediate outcome indicators for Preoperative Care in the intervention hospital improved (52.5% in 2009; 84.2% in 2011, pimproved to then decline again (63.3% in 2009; 70% in 2010; 58.6% in 2011). In the control group, preoperative care declined from 50.8% (2009) to 32.8% (2011, p improved, while at the same time final outcome declined (Surgical Case Fatality, Anaesthetic Complication Rate). Compared to the control group, final outcome improved more in the intervention hospital, although the effect was not significant over the whole study period. Documentation of final outcome indicators seemed inconsistent. Immediate outcome indicators seem more helpful to steer the Continuous Quality Improvement program. Conclusion Specific interventions as part of Continuous Quality Improvement might lead to sustainable improvement of the quality of care, if embedded in a multi-faceted approach. PMID:26327392

  13. Analytical quality control concept in the Euratom on-site laboratories

    International Nuclear Information System (INIS)

    Mayer, K.; Duinslaeger, L.; Cromboom, O.; Ottmar, H.; Wojnowski, D.; Vegt, H. van der

    2001-01-01

    Full text: Two on-site laboratories have been developed, installed, commissioned and put into routine operation by the Euratom safeguards office (ESO), jointly with the Institute for Transuranium Elements (ITU). These laboratories are operated by ITU staff and provide verification measurement results on samples taken by Euratom inspectors. The analysts work in weekly changing shift teams, manage the laboratories and operate the various analytical techniques. Operating such a laboratory at a remote location, without a senior scientist immediately available in case of problems, The existing boundary conditions challenge the robustness of the entire laboratory, i.e. comprising staff and instrumentation. In order to continuously ensure a high degree of reliability of the measurement results, a stringent quality control system was implemented. The quality control concept for the two on-site laboratories was developed at a very early stage and implemented in the pre-OSL training facility at ITU. This enabled to thoroughly test and develop further the concept. At the same time the analysts get acquainted with the quality control procedures in place and they are instilled with the principles. The quality control concept makes use of a fully computerized data management and data acquisition system. All measurement devices, including balances, density meters, mass spectrometers, passive neutron counter, hybrid K-edge instrument, gamma spectrometers and alpha spectrometers are networked and data exchange is performed on electronic basis. A specifically developed laboratory information management system collects individual measurement data, calculates intermediate and final result and shares the information with a quality control module. In order to ensure the reliability of the results, which are reported to the ESO inspectorate, five levels of quality control were implemented. The present paper describes in detail the different levels of quality control, which check the

  14. Quality control of CT units - methodology of performance I

    International Nuclear Information System (INIS)

    Prlic, I.; Radalj, Z.

    1996-01-01

    Increasing use of x-ray computed tomography systems (CT scanners) in the diagnostic requires an efficient means of evaluating the performance of them. Therefore, this paper presents the way to measure (Quality Control procedure-Q/C) and define the CT scanner performance through a special phantom which is based on the recommendation of the American association of Physicists in Medicine (AAPM). The performance parameters measurable with the phantom represent the capability, so periodical evaluation of the parameters enable the users to recognize the stability of the CT scanner no matter on the manufacturer, model or software option of the scanner. There are five important performance parameters which are to be measured: Noise, Contrast scale, Nominal tomographic section thickness, High and Low contrast resolution (MTF). The sixth parameter is, of course the dose per scan and slice which gives the patient dose for the certain diagnostic procedure. The last but not the least parameter is the final image quality which is given through the image processing device connected to the scanner. This is the final medical information needed for the good medical practice according to the Quality Assurance (Q/A) procedures in diagnostic radiology. We have to assure the results of the performance evaluation without environmental influences (the measurements are to be made under the certain conditions according Q/A). This paper will give no detailed methodology recipe but will show on the one example; the system noise measurements and linearity; the need and relevant results of the measurements.1 The rest of the methodology is to be published. (author)

  15. Validation of analytical methods for the quality control of Naproxen suppositories

    International Nuclear Information System (INIS)

    Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania; Garcia Pulpeiro, Oscar; Hernandez Contreras, Orestes Yuniel

    2011-01-01

    The analysis methods that will be used for the quality control of the future Cuban-made Naproxen suppositories for adults and children were developed for the first time in this paper. One method based on direct ultraviolet spectrophotometry was put forward, which proved to be specific, linear, accurate and precise for the quality control of Naproxen suppositories, taking into account the presence of chromophore groups in their structure. Likewise, the direct semi-aqueous acid-base volumetry method aimed at the quality control of the Naproxen raw material was changed and adapted to the quality control of suppositories. On the basis of the validation process, there was demonstrated the adequate specificity of this method with respect to the formulation components, as well as its linearity, accuracy and precision in 1-3 mg/ml range. The final results were compared and no significant statistical differences among the replicas per each dose were found in both methods; therefore, both may be used in the quality control of Naproxen suppositories

  16. Perceived Sleep Quality, Mood States, and Their Relationship With Performance Among Brazilian Elite Athletes During a Competitive Period.

    Science.gov (United States)

    Brandt, Ricardo; Bevilacqua, Guilherme G; Andrade, Alexandro

    2017-04-01

    Brandt, R, Bevilacqua, GG, and Andrade, A. Perceived sleep quality, mood states, and their relationship with performance among Brazilian elite athletes during a competitive period. J Strength Cond Res 31(4): 1033-1039, 2017-We described the perceived sleep quality and mood states of elite athletes during a competitive period, and clarified their relationship to athletes' sport performance. Participants were 576 Brazilian elite athletes (404 men and 172 women) of individual and team sports. Mood states were evaluated using the Brunel Mood Scale, whereas perceived sleep quality was evaluated using a single question ("How would you evaluate the quality of your sleep in the last few days?"). Evaluations of mood state and sleep quality were performed up to 60 minutes before national and international sports competitions began. Descriptive and inferential statistics (including logistic regression) were used to evaluate the relationship of sleep quality and mood states with performance (i.e., winning or losing). Athletes typically had good sleep quality and mood states similar to the Iceberg profile (i.e., high vigor and low tension, depression, anger, fatigue, and mental confusion). The Wald test revealed that sleep, anger, tension, and vigor predicted athletes' performance. Specifically, poor sleep quality and low vigor and anger decreased the odds of winning, whereas higher tension increased these odds. The Hosmer-Lemeshow test indicated that the results were sufficiently generalizable. Overall, we observed a significant relationship between sleep and mood states, which in turn both significantly influenced athletes' sports performance. Thus, coaching staff and athletes should monitor athletes' sleep quality before competitions to ensure athletes are in the optimal condition for performance.

  17. A modelling and control structure for product quality control in climate-controlled processing of agro-material

    NARCIS (Netherlands)

    Verdijck, G.J.C.; Straten, van G.

    2002-01-01

    In this paper a modelling and control structure for product quality control is presented for a class of operations that processes agro-material. This class can be characterised as climate-controlled operations, such as storage, transport and drying. The basic model consists of three parts. These are

  18. Organizing quality control programmes

    International Nuclear Information System (INIS)

    Hjardemaal, O.

    1989-01-01

    When procuring new equipment, performance and safety should be specified, if possible by reference to international standards. Some of the characteristics of the International Electrotechnical Commission (IEC) standard for X-ray generators, in particular the accuracy of the operating data, are described. The quality control tests to be performed after installation comprise acceptance test, status test and constancy test. The first two involve absolute measurements and will be the responsibility of physicists or engineers. Apparently limiting values stipulated by users are a factor of two lower than the limits of the IEC standard. By means of an example it is shown that modern X-ray generators can meet the lower limits of the users without problems. In order to obtain optimum initial quality when procuring new equipment operating data, limiting values must be specified and must be verified by acceptance testing, etc. However, in many countries physicists and engineers are not available for this job. A relatively uncomplicated test object can be used by radiographers for checks on fluoroscopic systems. The findings from such tests in Denmark are compared with other published findings and good agreement is found. Therefore it is proposed that such uncomplicated tests could form the basis for quality evaluation. (author)

  19. Quality control of test iodine in urine by spectrophotometry UV-Vis

    Science.gov (United States)

    Huda, Thorikul; Nafisah, Durotun; Kumorowulan, Suryati; Lestari, Sri

    2017-12-01

    A quality control of iodine test in with UV-Vis spectrophotometry has been done. The purpose of this research is to find out whether the test results of samples conducted by Clinical Office of Research and Development Of GAKI (BP2GAKI) laboratory are still controlled, feasible and reliable, and still consistent over time, as indicated by the control chart. Quality control parameters are linearity, precision, accuracy, limit of detection, and limit of quantification. Based on the quality control that has been done, obtained linearity (r)= -0.9974, the detection limit and the limit of quantitation are respectively 2.26 µg/L and 7.54 µg/L, while the accuracy is calculated by %recovery and precision with value % RSD are 97.4161% and 1.7136% respectively. The quality control of iodine test in urine using the control chart shows excellent or stable results for 30 days and no variation of the results is very different for each day.

  20. Quality control in diagnostic radiology: experience and challenges

    International Nuclear Information System (INIS)

    Abd Aziz Mhd Ramli; Mohd Ramli Arshad; Mohd Khalid Matori; Muhammad Jamal Md Isa; Husaini Salleh; Abdullah Tahir Aliyasak; Zainal Jamaluddin; Hasrul Hisham Hussain

    2005-01-01

    Malaysian Institute for Nuclear Technology Research through its Medical Physics Group has been providing Quality Control (QC) services for medical x-ray apparatus used in diagnostic radiology to private clinics and hospitals since the year 1997. The quality control (QC) in diagnostic radiology is considered as part of quality assurance program which provide accurate diagnostic information at the lowest cost and the least exposure of the patients to radiation. Many experience and obstacles were faced by Medical Physics Group. This paper will discuss on some of the experiences and challenges that could be shared together with MINT staff especially in the safety aspect related to electrical and mechanical, radiation protection, performance and standard. The challenging in administrative aspect also will discuss. (Author)

  1. Internal quality control of neutron activation analysis laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. H.; Mun, J. H.; BaeK, S. Y.; Jung, Y. S.; Kim, Y. J. [KAERI, Taejon (Korea, Republic of)

    2004-07-01

    The importance for quality assurance and control in analytical laboratories has been emphasized, day by day. Internal quality control using certified reference materials(CRMs) can be one of effective methods for this purpose. In this study, 10 kinds of CRMs consisting of soil, sediment and biological matrix were analyzed. To evaluate the confidence of analytical results and the validation of testing method and procedure, the accuracy and the precision of the measured elements were treated statistically and the reproducibility was compared with those values produced before 2003.

  2. Implementation to spanish protocol of quality control of accelerators to daily control of electron beams

    International Nuclear Information System (INIS)

    Adaimi Hernandez, P.; Ramirez Ros, J. C.; Casa de Julian, M. A. de la; Clemente Gutierrez, F.; Cabello Murillo, E.; Diaz Fuente, R.; Ferrando Sanchez, A.

    2011-01-01

    A revised procedure for daily control of the electron beams to make measurements more meaningful physically, having a better reproducibility and more in line with the recommendations of the Spanish Protocol for Quality Control in Electron Linear Accelerators Clinical Use. The daily quality control beams of high energy electrons that had been done so far was the finding that the record of a series of measures (symmetry, uniformity, stability, energy, beam central dose) were within tolerance values established. The amendment is to check the beam quality by directly measuring changes in absorption depth at which the dose is reduced to half its maximum value, R50.

  3. 40 CFR 81.63 - Metropolitan Fort Smith Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Metropolitan Fort Smith Interstate Air... Air Quality Control Regions § 81.63 Metropolitan Fort Smith Interstate Air Quality Control Region. The Metropolitan Fort Smith Interstate Air Quality Control Region (Arkansas-Oklahoma) has been revised to consist...

  4. Practical experience in the application of quality control in water-reactor fuel fabrication

    International Nuclear Information System (INIS)

    Vollath, D.

    1984-07-01

    Highly industrialized countries have gained vast experience in manufacturing water reactor fuel. Manufacturing is followed by a stringent system of quality assurance and quality control. The Seminar on Practical Experience in the Application of Quality Control in Water-Reactor Fuel Fabrication provided a forum for an exchange of information on methods and systems of quality assurance and quality control for reactor fuel. In addition, many developing countries which have started or intend to set up a nuclear fuel industry are interested in the application of quality assurance and quality control. This meeting has been preceded by two different series of conferences: the IAEA meetings 1976 in Oslo, 1978 in Prague and 1979 in Buenos Aires, and the Karlsruhe meetings on Characterization and Quality Control of Nuclear Fuel held in 1978 and 1981. Quality control and quality assurance has many different facets. Unlike the purely technical aspects, covered by the Karlsruhe conference series, the IAEA meetings always relate to a wider field of topics. They include governmental regulations and codes for practical quality assurance. This volume contains the papers presented at the seminar and a record of the discussions. (orig.)

  5. Mindcontrol: A web application for brain segmentation quality control.

    Science.gov (United States)

    Keshavan, Anisha; Datta, Esha; M McDonough, Ian; Madan, Christopher R; Jordan, Kesshi; Henry, Roland G

    2018-04-15

    Tissue classification plays a crucial role in the investigation of normal neural development, brain-behavior relationships, and the disease mechanisms of many psychiatric and neurological illnesses. Ensuring the accuracy of tissue classification is important for quality research and, in particular, the translation of imaging biomarkers to clinical practice. Assessment with the human eye is vital to correct various errors inherent to all currently available segmentation algorithms. Manual quality assurance becomes methodologically difficult at a large scale - a problem of increasing importance as the number of data sets is on the rise. To make this process more efficient, we have developed Mindcontrol, an open-source web application for the collaborative quality control of neuroimaging processing outputs. The Mindcontrol platform consists of a dashboard to organize data, descriptive visualizations to explore the data, an imaging viewer, and an in-browser annotation and editing toolbox for data curation and quality control. Mindcontrol is flexible and can be configured for the outputs of any software package in any data organization structure. Example configurations for three large, open-source datasets are presented: the 1000 Functional Connectomes Project (FCP), the Consortium for Reliability and Reproducibility (CoRR), and the Autism Brain Imaging Data Exchange (ABIDE) Collection. These demo applications link descriptive quality control metrics, regional brain volumes, and thickness scalars to a 3D imaging viewer and editing module, resulting in an easy-to-implement quality control protocol that can be scaled for any size and complexity of study. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Quality control of analogue to digital conversion circuitry for artefact-free SPECT imaging

    International Nuclear Information System (INIS)

    Gillen, G.J.; Elliott, A.T.

    1992-01-01

    A simple method for the objective, quantitative assessment of analogue to digital conversion (ADC) differential linearity has been developed for SPECT imaging. The analytical approach uses the fact that a differential non-linearity in the ADC will produce a non-uniformity in the digitized image which has a well defined periodicity. This can be most clearly demonstrated in the frequency space domain by determining the Fourier transform of a thick profile which is taken through the centre of a flood field image. The accuracy of the method permits deteriorations in the performance of ADCs to be detected well before significant reductions in SPECT image quality are produced. The availability of a quantitative measure of ADC performance, which can be tested objectively using a simple data acquisition method, is of value in the specification, acceptance testing and general quality control of gamma camera SPECT systems. (author)

  7. 21 CFR 111.130 - What quality control operations are required for returned dietary supplements?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for... and Process Control System: Requirements for Quality Control § 111.130 What quality control operations are required for returned dietary supplements? Quality control operations for returned dietary...

  8. Quality Assurance/Quality Control Jobs

    Science.gov (United States)

    Fanslau, Melody; Young, Janelle

    The production of a quality and safe food product is essential to the success of any food manufacturing facility. Because of this great importance, a career in quality can be extremely rewarding. Without happy customers willing to buy a product, a company would not be able to survive. Quality issues such as foreign objects, spoiled or mislabeled product, failure to meet net weight requirements, or a recall can all turn customers away from buying a product. The food industry is a customer-driven market in which some consumers are brand loyal based on a history of high quality or in which a single bad experience with a product will turn them away for a lifetime. With this said, the main role of a quality department is to help ensure that quality issues such as these are eliminated or kept to a minimum to maintain or increase the number of customers purchasing their product.

  9. Closed Loop Sawtooth Period Control Using Variable Eccd Injection Angles on Tore Supra

    International Nuclear Information System (INIS)

    Lennholm, M.; Eriksson, L.G.; Turco, F.; Bouquey, F.; Darbos, C.; Dumont, R.; Giruzzi, G.; Jung, M.; Lambert, R.; Magne, R.; Molina, D.; Moreau, P.; Rimini, F.; Segui, J.L.; Song, S.; Traisnel, E.

    2009-01-01

    Closed loop control of the period of fast ion stabilized sawtooth has been demonstrated for the first time on Tore Supra by varying the electron cyclotron current drive (ECCD) injection angles in real time. Fast ions generated by up to 4 MW of central ion cyclotron resonance heating (ICRH) increased the sawtooth period from the ohmic value of 25 ms to 60 to 100 ms. This sawtooth period was reduced to 30 ms by the addition of only 300 kW of ECCD. In ICRH heated shots where the normalized minor radius of the ECCD absorption location was swept from 0.4 to 0.05 in 4 s, the sawtooth period showed an abrupt change from 70 to 30 ms when the ECCD deposition normalized minor radius reached ∼ 0.2. This short period was then maintained until the absorption location moved well inside the sawtooth inversion radius at which point it abruptly returned to 70 ins. A closed loop controller was implemented that allowed the sawtooth period to be switched in real time between short and long sawteeth with a response time of the order of 1 s. (authors)

  10. Production And Quality Control Of Radiopharmaceutical 18F-FDG

    International Nuclear Information System (INIS)

    Dinh Thi Bich Lieu; Nguyen Van Si; Vu Van Tien

    2011-01-01

    18 F-FDG is a radiopharmaceutical for imaging diagnosis with PET/CT in Nuclear Medicine. Criteria of injection pharmaceuticals are the highest standards. So, quality assurance and quality control must be followed very strictly. The selection of the procedure for 18 F-FDG has based on several criteria: high chemical efficiency, short synthesis time, toxic component free and etc. The quality control of 18 F-FDG consist many fields such as: nuclear physic (nuclear purity), radiochemistry (radionuclear purity, radiochemical purity), chemistry (chemical purity), radiation measurement (half life), microbiology (pyrogen, endotoxin), etc. which is following USP, BP or EP. (author)

  11. Quality control of static irradiation processing products

    International Nuclear Information System (INIS)

    Bao Jianzhong; Chen Xiulan; Cao Hong; Zhai Jianqing

    2002-01-01

    Based on the irradiation processing practice of the nuclear technique application laboratory of Yangzhou Institute of Agricultural Science, the quality control of irradiation processing products is discussed

  12. [Development of whole process quality control and management system of traditional Chinese medicine decoction pieces based on traditional Chinese medicine quality tree].

    Science.gov (United States)

    Yu, Wen-Kang; Dong, Ling; Pei, Wen-Xuan; Sun, Zhi-Rong; Dai, Jun-Dong; Wang, Yun

    2017-12-01

    The whole process quality control and management of traditional Chinese medicine (TCM) decoction pieces is a system engineering, involving the base environment, seeds and seedlings, harvesting, processing and other multiple steps, so the accurate identification of factors in TCM production process that may induce the quality risk, as well as reasonable quality control measures are very important. At present, the concept of quality risk is mainly concentrated in the aspects of management and regulations, etc. There is no comprehensive analysis on possible risks in the quality control process of TCM decoction pieces, or analysis summary of effective quality control schemes. A whole process quality control and management system for TCM decoction pieces based on TCM quality tree was proposed in this study. This system effectively combined the process analysis method of TCM quality tree with the quality risk management, and can help managers to make real-time decisions while realizing the whole process quality control of TCM. By providing personalized web interface, this system can realize user-oriented information feedback, and was convenient for users to predict, evaluate and control the quality of TCM. In the application process, the whole process quality control and management system of the TCM decoction pieces can identify the related quality factors such as base environment, cultivation and pieces processing, extend and modify the existing scientific workflow according to their own production conditions, and provide different enterprises with their own quality systems, to achieve the personalized service. As a new quality management model, this paper can provide reference for improving the quality of Chinese medicine production and quality standardization. Copyright© by the Chinese Pharmaceutical Association.

  13. Quality Assurance/Quality Control Issues for Intraoperative Planning and Adaptive Repeat Planning of Image-Guided Prostate Implants

    International Nuclear Information System (INIS)

    Zaider, Marco; Cohen, Gilad; Meli, Jerome; Rosenfeld, Anatoly B.

    2008-01-01

    The quality assurance/quality control purpose is this. We design a treatment plan, and we wish to be as certain as reasonably possible that the treatment is delivered as planned. In the case of conventionally planned prostate brachytherapy, implementing to the letter the implantation plan is rarely attainable and therefore can require adaptive replanning (a quality control issue). The reasons for this state of affairs include changes in the prostate shape and volume during implantation and treatment delivery (e.g., edema resolution) and unavoidable inaccuracy in the placement of the seeds in the prostate. As a result, quality-control activities (e.g., the need to monitor-ideally, on the fly-the target and urethral and rectal dosage) must be also addressed

  14. Product quality control, irradiation and shipping procedures for mass-reared tephritid fruit flies for sterile insect release programmes

    International Nuclear Information System (INIS)

    1999-05-01

    This document represents the recommendations, reached by consensus of an international group of quality control experts, on the standard procedures for product quality control (QC) for mass reared tephritid flies that are to be used in Sterile Insect Technique (SIT) programs. In addition, the manual describes recommended methods of handling and packaging pupae during irradiation and shipment. Most of the procedures were designed specifically for use with Mediterranean fruit flies, Ceratitis capitata (Wied.), but they are applicable, with minor modification in some cases, for other tephritid species such as Caribbean fruit fly Anastrepha suspense, Mexican fruit fly A. ludens, and various Bactrocera species. The manual is evolving and subject to periodic updates. The future additions will include other fruit flies as the need is identified. If followed, procedures described in this manual will help ensure that the quality of mass-produced flies is measured accurately in a standardised fashion, allowing comparisons of quality over time and across rearing facilities and field programmes. Problems in rearing, irradiation and handling procedures, and strain quality can be identified and hopefully corrected before control programmes are affected. Tests and procedures described in this document are only part of a total quality control programme for tephritid fly production. The product QC evaluations included in this manual are, unless otherwise noted, required to be conducted during SIT programmes by the Field programme staff not the production staff. Additional product QC tests have been developed and their use is optional (see ancillary test section). Production and process QC evaluations (e.g., analysis of diet components, monitoring the rearing environment, yield of larvae, development rate, etc.) are not within the scope of this document. Quality specifications are included for minimum and mean acceptability of conventional strains of C. capitata, A. ludens, and A

  15. Quality Assurance and Control in Laboratory using Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. S.; Moon, J. H.; Sun, G. M.; Kim, S. H.; Baek, S. Y.; Lim, J. M.; Kim, H. R

    2007-01-15

    In accordance with the increment of international trade associated with the worldwide globalization, the importance of quality assurance and control for the commodity produced from one's own country has been stressed. ISO (International Organization for Standards) defines quality control as 'the operational techniques and activities that are used to fulfill the requirements for quality'. Since 1996, the HANARO research reactor in the Korea Atomic Energy Research Institute has been operated thereafter initial critical operation on April 1995. Neutron activation analysis system and applied techniques which is one of a nuclear analytical technologies using reactor neutrons has been developed for user's supporting and the establishment of the quality system for a measurement and analysis, testing and inspection was implemented successfully. On the basis of the qualified NAA system, the test and measurement of more than 1500 samples which is requested from 30 organizations including industrial companies, universities and institutes carried out in NAA laboratory annually. Moreover, as the goal of mutual recognition agreement (MRA) which can be removed a technical barrier in international trade, the objectivity and the confidence of analytical quality in NAA laboratory became established through the installation of international accreditation system by implementing analytical quality system in accordance with international standards in 2001. The aim of the report was to summarize the technical management of introduction, methods and the results for a quality control and assurance which should be performed in NAA technique using the HANARO research reactor. The report will help building up effective quality control strategy in the future.

  16. Quality Assurance and Control in Laboratory using Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Chung, Y. S.; Moon, J. H.; Sun, G. M.; Kim, S. H.; Baek, S. Y.; Lim, J. M.; Kim, H. R.

    2007-01-01

    In accordance with the increment of international trade associated with the worldwide globalization, the importance of quality assurance and control for the commodity produced from one's own country has been stressed. ISO (International Organization for Standards) defines quality control as 'the operational techniques and activities that are used to fulfill the requirements for quality'. Since 1996, the HANARO research reactor in the Korea Atomic Energy Research Institute has been operated thereafter initial critical operation on April 1995. Neutron activation analysis system and applied techniques which is one of a nuclear analytical technologies using reactor neutrons has been developed for user's supporting and the establishment of the quality system for a measurement and analysis, testing and inspection was implemented successfully. On the basis of the qualified NAA system, the test and measurement of more than 1500 samples which is requested from 30 organizations including industrial companies, universities and institutes carried out in NAA laboratory annually. Moreover, as the goal of mutual recognition agreement (MRA) which can be removed a technical barrier in international trade, the objectivity and the confidence of analytical quality in NAA laboratory became established through the installation of international accreditation system by implementing analytical quality system in accordance with international standards in 2001. The aim of the report was to summarize the technical management of introduction, methods and the results for a quality control and assurance which should be performed in NAA technique using the HANARO research reactor. The report will help building up effective quality control strategy in the future

  17. Seven Basic Tools of Quality Control: An Appropriate Tools for Solving Quality Problems in the Organizations

    OpenAIRE

    Neyestani, Behnam

    2017-01-01

    Dr. Kaoru Ishikawa was first total quality management guru, who has been associated with the development and advocacy of using the seven quality control (QC) tools in the organizations for problem solving and process improvements. Seven old quality control tools are a set of the QC tools that can be used for improving the performance of the production processes, from the first step of producing a product or service to the last stage of production. So, the general purpose of this paper was to...

  18. Incorporating Quality Control Information in the Sensor Web

    Science.gov (United States)

    Devaraju, Anusuriya; Kunkel, Ralf; Bogena, Heye

    2013-04-01

    The rapid development of sensing technologies had led to the creation of large amounts of heterogeneous environmental observations. The Sensor Web provides a wider access to sensors and observations via common protocols and specifications. Observations typically go through several levels of quality control, and aggregation before they are made available to end-users. Raw data are usually inspected, and related quality flags are assigned. Data are gap-filled, and errors are removed. New data series may also be derived from one or more corrected data sets. Until now, it is unclear how these kinds of information can be captured in the Sensor Web Enablement (SWE) framework. Apart from the quality measures (e.g., accuracy, precision, tolerance, or confidence), the levels of observational series, the changes applied, and the methods involved must be specified. It is important that this kind of quality control information is well described and communicated to end-users to allow for a better usage and interpretation of data products. In this paper, we describe how quality control information can be incorporated into the SWE framework. Concerning this, first, we introduce the TERENO (TERrestrial ENvironmental Observatories), an initiative funded by the large research infrastructure program of the Helmholtz Association in Germany. The main goal of the initiative is to facilitate the study of long-term effects of climate and land use changes. The TERENO Online Data RepOsitORry (TEODOOR) is a software infrastructure that supports acquisition, provision, and management of observations within TERENO via SWE specifications and several other OGC web services. Next, we specify changes made to the existing observational data model to incorporate quality control information. Here, we describe the underlying TERENO data policy in terms of provision and maintenance issues. We present data levels, and their implementation within TEODOOR. The data levels are adapted from those used by

  19. The Influence of Aging Period, Freezing Temperature and Packaging Material on Frozen Beef Chemical Quality

    Directory of Open Access Journals (Sweden)

    Aris Sri Widati

    2012-04-01

    Full Text Available The objective of the study was to evaluate the influences of aging period, freezing temperature and packaging material on the frozen beef chemical quality. The material of the study was 2-3 years old Ongole grade beef of the Longissimus dorsi part,  and was then classified into 3 treat­ments, namely A (aging periode; 0, 12 and 24 hours, B (freezing temperature; -10°C and -20°C and C (packaging material; aluminum foil (Al, polyprophylene (PP, poly­ethylene (PE and without packaging material. The ob­served variables were water content, crude protein, fat, ash content. The data were analyzed by the Completely Randomized Design (CRD in the Factorial (3x2x4 pattern. The results indicated that the aging periode de­creased the water content, and ash content significantly (P<0.05, and decreased the crude protein but increased the fat content insignificantly. The lower freezing temperature prevented the decreases of the water content, and ash content significantly (P<0.05, but prevented the decrease of crude protein, fat content insignificantly. The packaging material could prevent the decreases of water content, ash content sig­nificantly (P<0.05, but prevent the decreases of protein, and fat content insignificantly. A significant interaction (P<0.05 occured between the freezing temperature and packaging material factors on ash content of the frozen beef. The conclusion was the frozen beef without aging has a high of water content, protein, and ash, but has a low fat content.Temperature at -200C and using aluminium foil packaging can prevent decreasing quality of frozen beef. Keywords : Aging period, freezing temperature,  packaging material

  20. Quality Control Barriers in Adapting "Metro-Centric" Education to Regional Needs

    Science.gov (United States)

    Nagy, Judy; Robinson, Susan R.

    2013-01-01

    The massification and globalization of higher education, combined with the widespread adoption of processes underpinning accreditation and quality control of university programs, have tended to result in learning contexts that are increasingly narrowly conceived and tightly controlled. Underlying many quality control measures is a "one size…