WorldWideScience

Sample records for period specific electrical

  1. External control of the Drosophila melanogaster egg to imago development period by specific combinations of 3D low-frequency electric and magnetic fields.

    Science.gov (United States)

    Makarov, Vladimir I; Khmelinskii, Igor

    2016-01-01

    We report that the duration of the egg-to-imago development period of the Drosophila melanogaster, and the imago longevity, are both controllable by combinations of external 3-dimensional (3D) low-frequency electric and magnetic fields (LFEMFs). Both these periods may be reduced or increased by applying an appropriate configuration of external 3D LFEMFs. We report that the longevity of D. melanogaster imagoes correlates with the duration of the egg-to-imago development period of the respective eggs. We infer that metabolic processes in both eggs and imago are either accelerated (resulting in reduced time periods) or slowed down (resulting in increased time periods). We propose that external 3D LFEMFs induce electric currents in live systems as well as mechanical vibrations on sub-cell, whole-cell and cell-group levels. These external fields induce media polarization due to ionic motion and orientation of electric dipoles that could moderate the observed effects. We found that the longevity of D. melanogaster imagoes is affected by action of 3D LFEMFs on the respective eggs in the embryonic development period (EDP). We interpret this effect as resulting from changes in the regulation mechanism of metabolic processes in D. melanogaster eggs, inherited by the resulting imagoes. We also tested separate effects of either 3D electric or 3D magnetic fields, which were significantly weaker.

  2. Determining the specific electric resistance of rock

    Energy Technology Data Exchange (ETDEWEB)

    Persad' ko, V.Ia.

    1982-01-01

    Data are presented on perfecting the method of laboratory determination of the specific electric resistance of a rock formation. The average error in determining the specific electric resistance of the core at various locations is no more than two percent with low resistance values (2-5 ohms).

  3. A highly specific test for periodicity

    Energy Technology Data Exchange (ETDEWEB)

    Ansmann, Gerrit, E-mail: gansmann@uni-bonn.de [Department of Epileptology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Helmholtz Institute for Radiation and Nuclear Physics, University of Bonn, Nussallee 14–16, 53115 Bonn (Germany); Interdisciplinary Center for Complex Systems, University of Bonn, Brühler Straße 7, 53175 Bonn (Germany)

    2015-11-15

    We present a method that allows to distinguish between nearly periodic and strictly periodic time series. To this purpose, we employ a conservative criterion for periodicity, namely, that the time series can be interpolated by a periodic function whose local extrema are also present in the time series. Our method is intended for the analysis of time series generated by deterministic time-continuous dynamical systems, where it can help telling periodic dynamics from chaotic or transient ones. We empirically investigate our method's performance and compare it to an approach based on marker events (or Poincaré sections). We demonstrate that our method is capable of detecting small deviations from periodicity and outperforms the marker-event-based approach in typical situations. Our method requires no adjustment of parameters to the individual time series, yields the period length with a precision that exceeds the sampling rate, and its runtime grows asymptotically linear with the length of the time series.

  4. A highly specific test for periodicity

    International Nuclear Information System (INIS)

    Ansmann, Gerrit

    2015-01-01

    We present a method that allows to distinguish between nearly periodic and strictly periodic time series. To this purpose, we employ a conservative criterion for periodicity, namely, that the time series can be interpolated by a periodic function whose local extrema are also present in the time series. Our method is intended for the analysis of time series generated by deterministic time-continuous dynamical systems, where it can help telling periodic dynamics from chaotic or transient ones. We empirically investigate our method's performance and compare it to an approach based on marker events (or Poincaré sections). We demonstrate that our method is capable of detecting small deviations from periodicity and outperforms the marker-event-based approach in typical situations. Our method requires no adjustment of parameters to the individual time series, yields the period length with a precision that exceeds the sampling rate, and its runtime grows asymptotically linear with the length of the time series

  5. Electric fuses operation, a review: 2. Arcing period

    International Nuclear Information System (INIS)

    Bussière, W

    2012-01-01

    In the electric fuse operation the arcing period follows immediately the pre-arcing period depicted in Part 1 (Part 1. Pre-arcing period). The transition between these two operation steps is not fully understood at this time. To simplify the beginning of the arcing period can be identified with the electric arc ignition i.e. with the electrodes voltage drop. The consecutive plasma is of metallic type at the beginning of the arcing period and of metallic plus silica type with varying mixture up to the end of the arcing period. The energy brought by the fault current is withdrawn by means of the interaction between the electric arc and the arc quenching material (usually silica sand) whose morphometric properties influence the properties of the plasma column: composition, thermodynamic properties and transport coefficients of the plasma column depend on the porosity (and other morphometric properties) of the filler. The fuse element erosion also known as burn-back is responsible for the lengthening of the plasma column and the variations of the electric field. The whole of these processes is depicted by means of experimental results or modellings when possible.

  6. Electricity consumption and economic growth: Exploring panel-specific differences

    International Nuclear Information System (INIS)

    Karanfil, Fatih; Li, Yuanjing

    2015-01-01

    In this paper, we examine the long- and short-run dynamics between electricity consumption and economic activities, using panel data of per capita electricity consumption and per capita GDP of 160 countries for the period of 1980–2010, accounting for the degree of electricity dependence and the level of urbanization. Furthermore, in order to capture the differences in this relationship, the full sample is divided into various subsamples based on countries' income levels, regional locations and OECD memberships. This framework is argued and found to be appropriate since the causal links and inferences arising therefrom differ considerably among the subsamples, which led us to conclude that the electricity-growth nexus is highly sensitive to regional differences, countries' income levels, urbanization rates and supply risks. -- Highlights: •The causal relationship between electricity consumption and GDP is investigated. •Cointegration techniques are used for 160 countries and 13 subsamples. •Urbanization and electricity trade are accounted for as additional covariates. •Causal inferences are found to be associated with panel-specific differences. •Policy issues are discussed based on the study results

  7. Spin transport through electric field modulated graphene periodic ferromagnetic barriers

    International Nuclear Information System (INIS)

    Sattari, F.; Faizabadi, E.

    2014-01-01

    Using the transfer matrix method, the spin transmission coefficient and the spin conductivity are studied theoretically through the monolayer and bilayer graphene periodic ferromagnetic barriers modulated by a homogeneous electric field. The spin conductivity of the systems has an oscillatory behavior with respect to the external electric field which depends on the spin state of electron. In addition, the oscillation amplitude of the spin conductivity and spin polarization increase by increasing the number of barriers, but for a monolayer system with number of barriers greater than thirty, also for a bilayer system with the number of barriers greater than four, the oscillation amplitude does not change significantly. Our probes show that for bilayer system unlike monolayer structure the highest value of spin polarization achieved can be 1 or (−1). So, for designing spintronic devices, bilayer graphene is more efficient

  8. Periodic Seasonal Reg-ARFIMA-GARCH Models for Daily Electricity Spot Prices

    NARCIS (Netherlands)

    Ooms, M.; Koopman, S.J.; Carnero, A.M.

    2007-01-01

    Novel periodic extensions of dynamic long-memory regression models with autoregressive conditional heteroscedastic errors are considered for the analysis of daily electricity spot prices. The parameters of the model with mean and variance specifications are estimated simultaneously by the method of

  9. Comments on the Calculations of Specific Electricity and Fuel Consumption

    DEFF Research Database (Denmark)

    Jørgensen, Kaj

    1996-01-01

    Calculation of specific consumption of electricity and fuel for model electrical vehicles (passenger cars and vans). Both the present technological level and projected future technological developments. Used as background paper for a review of the scope for electrical vehicles in Denmark, carried...

  10. Prediction of electric energy consumption in Cuba for the period 2000-2015

    International Nuclear Information System (INIS)

    Garcia Rodirguez, B

    1999-01-01

    This paper consists on a prediction of the growth in electric energy consumption in Cuba, for the period 2000-2015 and with respect to 1990, it also considers the specific features of the National Electroenergetic System. Validated Guidelines in accordance with the Delphi method, which incorporates the basis characteristics considered by international programs for these predictions, were used for this purpose. From the analysis of the behaviour in power consumption of the different consumers and of the expected changes in them according to the expected scenarios, a prediction on the growth in the demand of electric energy is made

  11. Chapter A6. Section 6.3. Specific Electrical Conductance

    Science.gov (United States)

    Radtke, Dean B.; Davis, Jerri V.; Wilde, Franceska D.

    2005-01-01

    Electrical conductance is a measure of the capacity of a substance to conduct an electrical current. The specific electrical conductance (conductivity) of water is a function of the types and quantities of dissolved substances it contains, normalized to a unit length and unit cross section at a specified temperature. This section of the National Field Manual (NFM) describes U.S. Geological Survey (USGS) guidance and protocols for measurement of conductivity in ground and surface waters.

  12. Evaluation of environmental qualification period for Conax electrical penetration assemblies. Final report

    International Nuclear Information System (INIS)

    Doroshuk, B.; Hager, M.; Brown, R.

    1995-05-01

    This report evaluates the environmental qualification period of Conax electrical penetration assemblies (EPAs) for extension from forty (40) years to sixty (60) years. The evaluation was performed based on a review of Conax EPAs supplied to Baltimore Gas ampersand Electric's (BGE) Calvert Cliffs Nuclear Power Plant Units 1 and 2. The report has been prepared so that it may be of use to any utility involved in the extension of the environmental qualification period for Conax EPAs installed in their plant(s). The report includes a section on the strategy which was developed for the effort to extend the qualified lives of the Conax EPAs. A review of documentation and plant conditions specific to BGE is included in the report to demonstrate the methodology. The documentation included qualification testing performed by Conax of the materials of construction of the EPA models. The plant conditions reviewed included both normal and accident environments, both of which are specific to Calvert Cliffs Nuclear Power Plant Units 1 and 2. This report can be used as a guide in the evaluation of similar installations of Conax electrical penetration assemblies in other nuclear power plants by applying the methodologies used herein in conjunction with the plant specific test reports, materials, and conditions

  13. Periodic local MP2 method employing orbital specific virtuals

    International Nuclear Information System (INIS)

    Usvyat, Denis; Schütz, Martin; Maschio, Lorenzo

    2015-01-01

    We introduce orbital specific virtuals (OSVs) to represent the truncated pair-specific virtual space in periodic local Møller-Plesset perturbation theory of second order (LMP2). The OSVs are constructed by diagonalization of the LMP2 amplitude matrices which correspond to diagonal Wannier-function (WF) pairs. Only a subset of these OSVs is adopted for the subsequent OSV-LMP2 calculation, namely, those with largest contribution to the diagonal pair correlation energy and with the accumulated value of these contributions reaching a certain accuracy. The virtual space for a general (non diagonal) pair is spanned by the union of the two OSV sets related to the individual WFs of the pair. In the periodic LMP2 method, the diagonal LMP2 amplitude matrices needed for the construction of the OSVs are calculated in the basis of projected atomic orbitals (PAOs), employing very large PAO domains. It turns out that the OSVs are excellent to describe short range correlation, yet less appropriate for long range van der Waals correlation. In order to compensate for this bias towards short range correlation, we augment the virtual space spanned by the OSVs by the most diffuse PAOs of the corresponding minimal PAO domain. The Fock and overlap matrices in OSV basis are constructed in the reciprocal space. The 4-index electron repulsion integrals are calculated by local density fitting and, for distant pairs, via multipole approximation. New procedures for determining the fit-domains and the distant-pair lists, leading to higher efficiency in the 4-index integral evaluation, have been implemented. Generally, and in contrast to our previous PAO based periodic LMP2 method, the OSV-LMP2 method does not require anymore great care in the specification of the individual domains (to get a balanced description when calculating energy differences) and is in that sense a black box procedure. Discontinuities in potential energy surfaces, which may occur for PAO-based calculations if one is not

  14. Periodic local MP2 method employing orbital specific virtuals

    Energy Technology Data Exchange (ETDEWEB)

    Usvyat, Denis, E-mail: denis.usvyat@chemie.uni-regensburg.de; Schütz, Martin, E-mail: martin.schuetz@chemie.uni-regensburg.de [Institute for Physical and Theoretical Chemistry, Universität Regensburg, Universitätsstraße 31, D-93040 Regensburg (Germany); Maschio, Lorenzo, E-mail: lorenzo.maschio@unito.it [Dipartimento di Chimica, and Centre of Excellence NIS (Nanostructured Interfaces and Surfaces), Università di Torino, via Giuria 5, I-10125 Torino (Italy)

    2015-09-14

    We introduce orbital specific virtuals (OSVs) to represent the truncated pair-specific virtual space in periodic local Møller-Plesset perturbation theory of second order (LMP2). The OSVs are constructed by diagonalization of the LMP2 amplitude matrices which correspond to diagonal Wannier-function (WF) pairs. Only a subset of these OSVs is adopted for the subsequent OSV-LMP2 calculation, namely, those with largest contribution to the diagonal pair correlation energy and with the accumulated value of these contributions reaching a certain accuracy. The virtual space for a general (non diagonal) pair is spanned by the union of the two OSV sets related to the individual WFs of the pair. In the periodic LMP2 method, the diagonal LMP2 amplitude matrices needed for the construction of the OSVs are calculated in the basis of projected atomic orbitals (PAOs), employing very large PAO domains. It turns out that the OSVs are excellent to describe short range correlation, yet less appropriate for long range van der Waals correlation. In order to compensate for this bias towards short range correlation, we augment the virtual space spanned by the OSVs by the most diffuse PAOs of the corresponding minimal PAO domain. The Fock and overlap matrices in OSV basis are constructed in the reciprocal space. The 4-index electron repulsion integrals are calculated by local density fitting and, for distant pairs, via multipole approximation. New procedures for determining the fit-domains and the distant-pair lists, leading to higher efficiency in the 4-index integral evaluation, have been implemented. Generally, and in contrast to our previous PAO based periodic LMP2 method, the OSV-LMP2 method does not require anymore great care in the specification of the individual domains (to get a balanced description when calculating energy differences) and is in that sense a black box procedure. Discontinuities in potential energy surfaces, which may occur for PAO-based calculations if one is not

  15. Research on minimum sound specifications for hybrid and electric vehicles

    Science.gov (United States)

    2012-06-30

    This report documents research by the National Highway Traffic Safety Administration (NHTSA) to identify ways : to develop sound specifications for electric and hybrid vehicles. The research was conducted to support activities : related to the implem...

  16. 101 Modelling and Forecasting Periodic Electric Load for a ...

    African Journals Online (AJOL)

    User

    2012-01-24

    Jan 24, 2012 ... Electricity load consumption in Nigeria is of great concern and its government is ... This is because the energy needed for any system is based on ... is a tool for verifying the validity and reliability of a chosen model. It tells how ...

  17. Evaluation of electric power distribution systems: period 1984/89

    International Nuclear Information System (INIS)

    Britto Filho, W.A. de; Pinto, V.G.

    1992-01-01

    The historical evolution of electric power distribution systems in Brazil, during 1984 to 1989 is described, showing the consumer market with the physical expansion of Distribution Networks and the results of quality from the services made by the companies to their clients. (C.G.C.)

  18. Multi-period emissions trading in the electricity sector-winners and losers

    International Nuclear Information System (INIS)

    Bode, Sven

    2006-01-01

    In the context of controlling greenhouse gas emissions, the directive on a Europe-wide trading scheme may be perceived as one of the most important milestones in recent years. Prior to its start, however, a number of very specific design features have to be agreed upon. Regarding the allocation of allowances, a distribution (almost) free of charge seems to be the most likely choice. An aspect that has interestingly attracted little attention in the past is the question of how to allocate emission rights over time. The following paper analyses different allocation options in multi-period emissions trading that are currently discussed in the European context. The options are applied for the electricity sector which is simulated over two periods. The paper distinguishes between a market effect of emissions trading and compliance costs for meeting the emission reduction obligation. The market effect results from a price increase which is due to the fact that opportunity costs for using allowances must be considered. It turns out that the electricity sector as a whole gains from the introduction of the instrument due to the increase of the electricity price. With regard to the different allocation options, it is found that utilities have different preferences depending on the fuel used

  19. High-latitude long-period pulsations in the atmospheric electricity according to observations at Schpitzbergen

    International Nuclear Information System (INIS)

    Klejmenova, N.G.; Kozyreva, O.V.; Mikhnovski, S.; Shimanski, A.; Ermolenko, D.Yu.

    1992-01-01

    The spectrum of long-period oscillations in the electric and magnetic fields is investigated for the first time using the data on simultaneous digital recording in the high altitudes at Schpitzbergen. It is established that during both tranquil and perturbed period at any time of the day, spectrum variation in electric and magnetic fields feature a decline discrete nature

  20. Standard technical specifications for General Electric boiling water reactors

    International Nuclear Information System (INIS)

    1979-08-01

    This Standard Technical Specification (STS) has been structured for the broadest possible use on General Electric plants currently being reviewed for an Operating License. Optional specifications are provided for those features and systems which may be included in individual plant designs but are not generic in their scope of application. This revision of the GE-STS does not typically include requirements which may be added or revised as a result of the NRC staff's further review of the Three Mile Island incident

  1. Specific features of elite bodybuilders’ training process in competition period

    Directory of Open Access Journals (Sweden)

    A.A. Tihorsky

    2016-12-01

    Full Text Available Purpose: To substantiate methodic of training process construction for elite bodybuilders in competition period with usage of different training methods. Material: elite bodybuilders - members of combined team of Ukraine (n=16 participated in the research. Results: we presented comparative characteristic of the most often used bodybuilding training methodic. Besides, optimal training methodic in competition period was worked out and substantiated. Such methodic permits to improve body proportions at the account of fat layer reduction. By the data of Harvard step-test the sportsmen improved organism’s functional potentials by 6%. Conclusions: the offered methodic noticeably reduces probability of functional unfavorable states (over-training, overloading, traumas. The methodic permits to achieve the required sport form without over-tension adaptation-compensatory mechanisms and acquire maximal muscular relief; improve proportions with minimal losses of muscles’ volume.

  2. Local electric dipole moments for periodic systems via density functional theory embedding.

    Science.gov (United States)

    Luber, Sandra

    2014-12-21

    We describe a novel approach for the calculation of local electric dipole moments for periodic systems. Since the position operator is ill-defined in periodic systems, maximally localized Wannier functions based on the Berry-phase approach are usually employed for the evaluation of local contributions to the total electric dipole moment of the system. We propose an alternative approach: within a subsystem-density functional theory based embedding scheme, subset electric dipole moments are derived without any additional localization procedure, both for hybrid and non-hybrid exchange-correlation functionals. This opens the way to a computationally efficient evaluation of local electric dipole moments in (molecular) periodic systems as well as their rigorous splitting into atomic electric dipole moments. As examples, Infrared spectra of liquid ethylene carbonate and dimethyl carbonate are presented, which are commonly employed as solvents in Lithium ion batteries.

  3. Local electric dipole moments for periodic systems via density functional theory embedding

    Energy Technology Data Exchange (ETDEWEB)

    Luber, Sandra, E-mail: sandra.luber@chem.uzh.ch [Institut für Chemie, Universität Zürich, Winterthurerstrasse 190, 8057 Zürich (Switzerland)

    2014-12-21

    We describe a novel approach for the calculation of local electric dipole moments for periodic systems. Since the position operator is ill-defined in periodic systems, maximally localized Wannier functions based on the Berry-phase approach are usually employed for the evaluation of local contributions to the total electric dipole moment of the system. We propose an alternative approach: within a subsystem-density functional theory based embedding scheme, subset electric dipole moments are derived without any additional localization procedure, both for hybrid and non-hybrid exchange–correlation functionals. This opens the way to a computationally efficient evaluation of local electric dipole moments in (molecular) periodic systems as well as their rigorous splitting into atomic electric dipole moments. As examples, Infrared spectra of liquid ethylene carbonate and dimethyl carbonate are presented, which are commonly employed as solvents in Lithium ion batteries.

  4. A Model for Periodic Nonlinear Electric Field Structures in Space Plasmas

    International Nuclear Information System (INIS)

    Qureshi, M.N.S.; Shi Jiankui; Liu Zhenxing

    2009-01-01

    In this study, we present a physical model to explain the generation mechanism of nonlinear periodic waves with a large amplitude electric field structures propagating obliquely and exactly parallel to the magnetic field. The 'Sagdeev potential' from the MHD equations is derived and the nonlinear electric field waveforms are obtained when the Mach number, direction of propagation, and the initial electric field satisfy certain plasma conditions. For the parallel propagation, the amplitude of the electric field waves with ion-acoustic mode increases with the increase of initial electric field and Mach number but its frequency decreases with the increase of Mach number. The amplitude and frequency of the electric field waves with ion-cyclotron mode decrease with the increase of Mach number and become less spiky, and its amplitude increases with the increase of initial electric field. For the oblique propagation, only periodic electric field wave with an ion-cyclotron mode obtained, its amplitude and frequency increase with the increase of Mach number and become spiky. From our model the electric field structures show periodic, spiky, and saw-tooth behaviours corresponding to different plasma conditions.

  5. Application Protocol, Initial Graphics Exchange Specification (IGES), Layered Electrical Product

    Energy Technology Data Exchange (ETDEWEB)

    O`Connell, L.J. [ed.

    1994-12-01

    An application protocol is an information systems engineering view of a specific product The view represents an agreement on the generic activities needed to design and fabricate the product the agreement on the information needed to support those activities, and the specific constructs of a product data standard for use in transferring some or all of the information required. This application protocol describes the data for electrical and electronic products in terms of a product description standard called the Initial Graphics Exchange Specification (IGES). More specifically, the Layered Electrical Product IGES Application Protocol (AP) specifies the mechanisms for defining and exchanging computer-models and their associated data for those products which have been designed in two dimensional geometry so as to be produced as a series of layers in IGES format The AP defines the appropriateness of the data items for describing the geometry of the various parts of a product (shape and location), the connectivity, and the processing and material characteristics. Excluded is the behavioral requirements which the product was intended to satisfy, except as those requirements have been recorded as design rules or product testing requirements.

  6. Evaluation of Waterford Steam Electric Station Unit 3 technical specifications

    International Nuclear Information System (INIS)

    Baxter, D.E.; Bruske, S.J.

    1985-09-01

    This document was prepared for the Nuclear Regulatory Commission (NRC) to assist them in determining whether the Waterford Steam Electric Station Unit 3 Technical Specifications (T/S), which govern plant systems configurations and operations, are in conformance with the requirements of the Final Safety Analysis Report (FSAR) as amended, and the requirements of the Safety Evaluation Report (SER) as supplemented. A comparative audit of the FSAR as amended, and the SER as supplemented was performed with the Waterford T/S. Several discrepancies were identified and subsequently resolved by the cognizant NRC reviewer. Pending completion of the resolutions noted in Part 3 of this report, the Waterford Steam Electric Station Unit 3 T/S, to the extent reviewed, are in conformance with the FSAR and SER

  7. Standard Technical Specifications, General Electric plants, BWR/4

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for General Electric Plants, BWR/4, and documents the positions of the Nuclear Regulatory Commission based on the BWR Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power specifications. This report contains three volumes. This document, Volume 2, contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS

  8. Standard Technical Specifications for General Electric Boiling Water Reactors (BWR/5)

    International Nuclear Information System (INIS)

    Bottimore, R.R.

    1980-12-01

    The Standard Technical Specifications for General Electric Boiling Water Reactors (GE-STS) is a generic document prepared by the US NRC for use in the licensing process of current General Electric Boiling Water Reactors. The GE-STS sets forth the limits, operating conditions, and other requirements applicable to nuclear reactor facility operation as set forth by Section 50.36 of 10 CFR Part 50 for the protection of the health and safety of the public. The document is revised periodically to reflect current licensing requirements

  9. Standard Technical Specifications, General Electric plants, BWR/4

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for General Electric Plants, BWR/6, and documents the positions of the Nuclear Regulatory Commission based on the B ampersand W Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. This document Volume 3, contains the Bases for Sections 3.4--3.10 of the improved STS

  10. Standard Technical Specifications, General Electric Plants, BWR/6

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for General Electric Plants, BWR/6, and documents the positions of the Nuclear Regulatory Commission based on the B ampersand W Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. This document Volume 1, contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. Volume 3 contains the Bases for Sections 3.4--3.10 of the improved STS

  11. Standard Technical Specifications, General Electric plants, BWR/4

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for General Electric Plants, BWR/6, and documents the positions of the Nuclear Regulatory Commission based on the BWR Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. This document Volume 1 contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. Volume 3 contains the Bases for Sections 3.4--3.10 of the improved STS

  12. Standard Technical Specifications, General Electric Plants, BWR/6

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for General Electric Plants, BWR/4, and documents the positions of the Nuclear Regulatory Commission based on the BWR Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. Volume 3, contains the Bases for Sections 3.4--3.10 of the improved STS

  13. Standard Technical Specifications, General Electric plants, BWR/6

    International Nuclear Information System (INIS)

    1992-09-01

    This NUREG contains improved Standard Technical Specifications (STS) for General Electric Plants, BWR/6, and documents the positions of the Nuclear Regulatory Commission based on the B ampersand W Owners Group's proposed STS. This document is the result of extensive technical meetings and discussions among the NRC staff, the Nuclear Steam Supply System (NSSS) Owners Groups, the NSSS vendors, and the Nuclear Management and Resources Council (NUMARC). The improved STS were developed based on the criteria in the interim Commission Policy Statement on Technical Specification Improvements for Nuclear Power Reactors, dated February 6, 1987. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the Specifications for all chapters and sections of the improved STS. This document Volume 2, contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. Volume 3 contains the Bases for Sections 3.4--3.10 of the improved STS

  14. Analysis of the electricity supply-demand balance for the winter period 2009-2010

    International Nuclear Information System (INIS)

    2009-10-01

    Every year, RTE conducts a prospective study of the balance between supply and demand for electricity for the coming winter period, covering the whole of mainland France. This period of the year is looked at closely, primarily due to the high levels of electricity demand seen during cold snaps. The study by RTE is used to identify periods where the supply-demand balance comes under strain; it explores the measures that can be taken by electricity market players and RTE to avoid any interruption in supply during peak demand periods in France. RTE is responsible for managing the balance between supply and demand for electricity in mainland France, in real time. To do this, it anticipates potential risks that may supply may come under strain - well in advance - and informs market players. If periods are identified where the supply-demand balance comes under strain, RTE works with the electricity generators to look at possible ways of altering the schedules for shutting down generating units, and takes account of the possibilities for demand response (load reduction) reported by suppliers. As a last resort, if these preemptive measures prove insufficient and the situation becomes critical, RTE alerts the government of the risk that supply will be interrupted, and takes action in real time to limit the impact on the power system. For temperatures close to seasonal norms, the forecast outlook for the electricity supply-demand balance appears significantly less favourable than last winter until the end of January. Imports could be required between mid-November 2009 and the end of January 2010, to cover electricity demand in France and satisfy the technical security margin stipulated by RTE. To do this, suppliers would have to look to the European markets, in addition to activating demand response (load reduction) possibilities with their customer portfolios. In the event of an intense and sustained spell of cold weather, the technical limit for imports into the French

  15. Specification of merger gains in the Norwegian electricity distribution industry

    International Nuclear Information System (INIS)

    Saastamoinen, Antti; Bjørndal, Endre; Bjørndal, Mette

    2017-01-01

    Electricity distribution often exhibits economies of scale. In Norway, a number of smaller distribution system operators exist and thus there is potential to restructure the industry, possibly through mergers. However, the revenue cap regulatory model in Norway does not incentivize firms to merge as merging leads to a stricter revenue cap for the merged company. Thus the regulator compensates the firms in order to create such incentives. The amount of compensation is based on the potential gains of the merger estimated using a data envelopment analysis (DEA) based frontier approach introduced by Bogetoft and Wang (2005). DEA is however only one of many possible frontier estimators that can be used in estimation. Furthermore, the returns to scale assumption, the operating environment of firms and the presence of stochastic noise and outlier observations are all known to affect to the estimation of production technology. In this paper we explore how varying assumptions under two alternative frontier estimators shape the distribution of merger gains within the Norwegian distribution industry. Our results reveal that the restructuring policies of the industry may be significantly altered depending how potential gains from the mergers are estimated. - Highlights: • The merger gains of Norwegian electricity distribution firm are investigated. • Different estimators and model specifications are applied. • Results show that the gains are significantly affected by the model choice. • Incentives to merge may be shaped through the estimation of gains.

  16. Randomly modulated periodic signals in Alberta's electricity market

    Energy Technology Data Exchange (ETDEWEB)

    Hinich, M. [Texas Univ., Austin, TX (United States); Serletis, A. [Calgary Univ., AB (Canada)

    2005-04-01

    The physical laws that determine the delivery of power across a transmission grid require a synchronized energy balance between the injection of power at generating points and offtake at demand points. Grid operators must continuously monitor the demand process and respond quickly to fluctuations in demand. This paper presented a parametric statistical model called Randomly Modulated Periodicity (RMP) which examined Alberta's spot wholesale power market, defined on hourly intervals. The concern was to test for periodic signals that can be perfectly predicted far into the future. A univariate approach was taken, although it was acknowledged that from an economic perspective, the interest in the price of electricity is in its relationship with the electricity load as well as with the prices of other primary fuel commodities. Sections 2 and 3 of the paper discussed the RMP model for the study of periodic signals. In section 4, randomly modulated periodicity was tested in hourly electricity prices and MWh demand for Alberta, over the deregulated period after 1996. It was concluded that electricity prices have low coherence with daily and weekly cycles. The mean value at each half hour of the daily demand and the weekend demand yielded good forecasts after the end of the data series. It was suggested that a statistical forecasting based on historical demand and co-factors such as the average hourly temperature per day and patterns of industrial usage should yield better short term forecasts. The development of a statistical technology for forecasting electricity demand is a challenging area of research. 6 refs., 4 figs.

  17. Standard technical specifications: General Electric plants, BWR/4. Volume 1, Revision 1: Specifications

    International Nuclear Information System (INIS)

    1995-04-01

    This report documents the results of the combined effort of the NRC and the industry to produce improved Standard Technical Specifications (STS), Revision 1 for General Electric BWR/4 Plants. The changes reflected in Revision 1 resulted from the experience gained from license amendment applications to convert to these improved STS or to adopt partial improvements to existing technical specifications. This NUREG is the result of extensive public technical meetings and discussions between the Nuclear Regulatory Commission (NRC) staff and various nuclear power plant licensees, Nuclear Steam Supply System (NSSS) Owners Groups, NSSS vendors, and the Nuclear Energy Institute (NEI). The improved STS were developed based on the criteria in the Final Commission Policy Statement on Technical Specifications Improvements for Nuclear Power Reactors, dated July 22, 1993. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. Volume 3 contains the Bases for Sections 3.4--3.10 of the improved STS

  18. Stability of horizontal viscous fluid layers in a vertical arbitrary time periodic electric field

    Science.gov (United States)

    Bandopadhyay, Aditya; Hardt, Steffen

    2017-12-01

    The stability of a horizontal interface between two viscous fluids, one of which is conducting and the other is dielectric, acted upon by a vertical time-periodic electric field is considered theoretically. The two fluids are bounded by electrodes separated by a finite distance. For an applied ac electric field, the unstable interface deforms in a time periodic manner, owing to the time dependent Maxwell stress, and is characterized by the oscillation frequency which may or may not be the same as the frequency of the ac electric field. The stability curve, which relates the critical voltage, manifested through the Mason number—the ratio of normal electric stress and viscous stress, and the instability wavenumber at the onset of the instability, is obtained by means of the Floquet theory for a general arbitrary time periodic electric field. The limit of vanishing viscosities is shown to be in excellent agreement with the marginal stability curves predicted by means of a Mathieu equation. The influence of finite viscosity and electrode separation is discussed in relation to the ideal case of inviscid fluids. The methodology to obtain the marginal stability curves developed here is applicable to any arbitrary but time periodic signal, as demonstrated for the case of a signal with two different frequencies, and four different frequencies with a dc offset. The mode coupling in the interfacial normal stress leads to appearance of harmonic and subharmonic modes, characterized by the frequency of the oscillating interface at an integral or half-integral multiple of the applied frequency, respectively. This is in contrast to the application of a voltage with a single frequency which always leads to a harmonic mode oscillation of the interface. Whether a harmonic or subharmonic mode is the most unstable one depends on details of the excitation signal.

  19. Selection of strategy for electric power engineering development in Russia for period up to 2015

    International Nuclear Information System (INIS)

    Khainson, Ya.I.; Mirkovskaya, R.E.; Artem'eva, N.Yu.

    1993-01-01

    The result of studies, in which an attempt to select a number of real versions for development of electric power engineering for the period up to 2015, as well as to evaluate, compare and select essentially stable trends is made, are discussed. It is shown that these trends remain actual even under market economics conditions. The necessity is emphasized for creation and introduction of new generation of units and electric power plants ecologically clean, reliable and operating in wide unit capacity range. Special attention should be paid to creation of new types of NPPs, underground NPPs as well as low-and intermediate-capacity NPPs necessary for many regions of the country

  20. Energy integration on multi-periods and multi-usages for hybrid electric and thermal powertrains

    International Nuclear Information System (INIS)

    Dimitrova, Zlatina; Maréchal, François

    2015-01-01

    The improvement of the efficiency of vehicle energy systems promotes an active search to find innovative solutions during the design process. This requires more accurate modeling of complex systems, which offers new ways to improve the design efficiency of energy systems. The vehicle is a highly dynamic system. The size and the efficiency of the convertors are dependent on the dynamic driving profile. In order to increase the energy efficiency, using energy integration techniques, an adapted methodology is required to choose the best points for the integrated system design. The idea is to clusterize the dynamic profile on typical multi-periods of the vehicle use. The energy system design is then optimized for these typical multi-periods. In this article a new methodology is applied on hybrid electric vehicles, in order to define the energy integrated powertrain configuration of the vehicle. The energy recovery potential of a single stage Organic Rankine Cycle for a thermal engine in combination with a hybrid electric powertrain is assessed for different drive cycles profiles and comfort situations. After the energy integration, a multi-objective optimization is applied to define the optimal design of a hybrid electric vehicle with a waste heat recovery system. - Highlights: • K-means algorithm transforms the dynamic driving profile on static multi-periods. • The clusters represent the typical powertrain use and size the heat recovery utility. • The maximal heat recovery potential on thermal powertrains is 11% for urban driving. • The maximal heat recovery potential on hybrid electric powertrains is 5%. • Engine downsizing increases heat recovery potential on hybrid electric powertrains

  1. Nonlinear analysis of field distribution in electric motor with periodicity conditions

    Energy Technology Data Exchange (ETDEWEB)

    Stabrowski, M M; Sikora, J

    1981-01-01

    Numerical analysis of electromagnetic field distribution in linear motion tubular electric motor has been performed with the aid of finite element method. Two Fortran programmes for the solution of DBBF and BF large linear symmetric equation systems have been developed for purposes of this analysis. A new iterative algorithm, taking into account iron nonlinearity and periodicity conditions, has been introduced. Final results of the analysis in the form of induction diagrammes and motor driving force are directly useful for motor designers.

  2. Enhanced transmission of transverse electric waves through periodic arrays of structured subwavelength apertures

    DEFF Research Database (Denmark)

    Xiao, Sanshui; Peng, Liang; Mortensen, Asger

    2010-01-01

    Transmission through sub-wavelength apertures in perfect metals is expected to be strongly suppressed. However, by structural engineering of the apertures, we numerically demonstrate that the transmission of transverse electric waves through periodic arrays of subwavelength apertures in a thin...... metallic film can be significantly enhanced. Based on equivalent circuit theory analysis, periodic arrays of square structured subwavelength apertures are obtained with a 1900-fold transmission enhancement factor when the side length a of the apertures is 10 times smaller than the wavelength (a/λ =0...

  3. Hybrid Electric Energy Storages: Their Specific Features and Application (Review)

    Science.gov (United States)

    Popel', O. S.; Tarasenko, A. B.

    2018-05-01

    The article presents a review of various aspects related to development and practical use of hybrid electric energy storages (i.e., those uniting different energy storage technologies and devices in an integrated system) in transport and conventional and renewable power engineering applications. Such devices, which were initially developed for transport power installations, are increasingly being used by other consumers characterized by pronounced nonuniformities of their load schedule. A range of tasks solved using such energy storages is considered. It is shown that, owing to the advent of new types of energy storages and the extended spectrum of their performance characteristics, new possibilities for combining different types of energy storages and for developing hybrid systems have become available. This, in turn, opens up the possibility of making energy storages with better mass and dimension characteristics and achieving essentially lower operational costs. The possibility to secure more comfortable (base) operating modes of primary sources of energy (heat engines and renewable energy source based power installations) and to achieve a higher capacity utilization factor are unquestionable merits of hybrid energy storages. Development of optimal process circuit solutions, as well as energy conversion and control devices facilitating the fullest utilization of the properties of each individual energy storage included in the hybrid system, is among the important lines of research carried out in this field in Russia and abroad. Our review of existing developments has shown that there are no universal technical solutions in this field (the specific features of a consumer have an essential effect on the process circuit solutions and on the composition of a hybrid energy storage), a circumstance that dictates the need to extend the scope of investigations in this promising field.

  4. Periodic variations of atmospheric electric field on fair weather conditions at YBJ, Tibet

    Science.gov (United States)

    Xu, Bin; Zou, Dan; Chen, Ben Yuan; Zhang, Jin Ye; Xu, Guo Wang

    2013-05-01

    Observations of atmospheric electric field on fair weather conditions from the plateau station, YBJ, Tibet (90°31‧50″ E, 30°06‧38″ N), over the period from 2006 to 2011, are presented in this work. Its periodic modulations are analyzed in frequency-domain by Lomb-Scargle Periodogram method and in time-domain by folding method. The results show that the fair weather atmospheric electric field intensity is modulated weakly by annual cycle, solar diurnal cycle and its several harmonic components. The modulating amplitude of annual cycle is bigger than that of solar diurnal cycle. The annual minimum/maximum nearly coincides with spring/autumn equinox. The detailed spectrum analysis show that the secondary peaks (i.e. sidereal diurnal cycle and semi-sidereal diurnal cycle) nearly disappear along with their primary peaks when the primary signals are subtracted from electric field data sequence. The average daily variation curve exhibits dual-fluctuations, and has obviously seasonal dependence. The mean value is bigger in summer and autumn, but smaller in spring and winter. The daytime fluctuation is affected by the sunrise and sunset effect, the occurring time of which have a little shift with seasons. However, the nightly one has a great dependence on season conditions.

  5. Transition from steady to periodic liquid-metal magnetohydrodynamic flow in a sliding electrical contact

    Science.gov (United States)

    Talmage, Gita; Walker, John S.; Brown, Samuel H.; Sondergaard, Neal A.

    1993-09-01

    In homopolar motors and generators, large dc electric currents pass through the sliding electrical contacts between rotating copper disks (rotors) and static copper surfaces shrouding the rotor tips (stators). A liquid metal in the small radial gap between the rotor tip and concentric stator surface can provide a low-resistance, low-drag electrical contact. Since there is a strong magnetic field in the region of the electrical contacts, there are large electromagnetic body forces on the liquid metal. The primary, azimuthal motion consists of simple Couette flow, plus an electromagnetically driven flow with large extremes of the azimuthal velocity near the rotor corners. The secondary flow involves the radial and axial velocity components, is driven by the centrifugal force associated with the primary flow, and is opposed by the electromagnetic body force, so that the circulation varies inversely as the square of the magnetic-field strength. Three flow regimes are identified as the angular velocity Ω of the rotor is increased. For small Ω, the primary flow is decoupled from the secondary flow. As Ω increases, the secondary flow begins to convect the azimuthal-velocity peaks radially outward, which in turn changes the centrifugal force driving the secondary flow. At some critical value of Ω, the flow becomes periodic through the coupling of the primary and secondary flows. The azimuthal-velocity peaks begin to move radially in and out with an accompanying oscillation in the secondary-flow strength.

  6. Social demand for electricity from forest biomass in Spain: Does payment periodicity affect the willingness to pay?

    International Nuclear Information System (INIS)

    Solino, Mario; Vazquez, Maria X.; Prada, Albino

    2009-01-01

    In this article, we analyze social preferences for a partial substitution programme of electricity generated by conventional energy sources, for energy generated from a local renewable energy source, such as forest biomass. This analysis sets arguments in favour of accelerating the introduction of this renewable technology in the Spanish Electricity System. Simultaneously, two methodological goals concerning the contingent valuation method are discussed. In the first one, we analyze if there are statistical differences in the willingness to pay (WTP) when a single- or a double-bounded format is employed to ask the valuation question. Results show that WTP estimates from single- and double-bounded significantly differ. In the second one, we analyze the effect of the periodicity of the payment vehicle on the estimates of welfare change. The timeframe specification of the payment vehicle has been scarcely studied, and this fact constitutes the main contribution of this paper to the specialized literature. Results show that periodicity influences upon the probability to favour the proposed change. The periodicity does not affect to the mean WTP obtained in the single-bounded format, but there are statistical differences in the double-bounded format. These results might be explained by the presence of yea saying and payment scale bias

  7. Tailoring of the electrical and thermal properties using ultra-short period non-symmetric superlattices

    Directory of Open Access Journals (Sweden)

    Paulina Komar

    2016-10-01

    Full Text Available Thermoelectric modules based on half-Heusler compounds offer a cheap and clean way to create eco-friendly electrical energy from waste heat. Here we study the impact of the period composition on the electrical and thermal properties in non-symmetric superlattices, where the ratio of components varies according to (TiNiSnn:(HfNiSn6−n, and 0 ⩽ n ⩽ 6 unit cells. The thermal conductivity (κ showed a strong dependence on the material content achieving a minimum value for n = 3, whereas the highest value of the figure of merit ZT was achieved for n = 4. The measured κ can be well modeled using non-symmetric strain relaxation applied to the model of the series of thermal resistances.

  8. Electrical conductivity testing of corn seeds as influenced by temperature and period of storage

    OpenAIRE

    Fessel,Simone Aparecida; Vieira,Roberval Daiton; Cruz,Mara Cristina Pessoa da; Paula,Rinaldo Cesar de; Panobianco,Maristela

    2006-01-01

    The objective of this work was to evaluate the effects of temperature (10, 20, 30, 20/10 and 30/10ºC) and period of storage on electrical conductivity (EC) in four seed lots of corn (Zea mays L.), as well as the mineral composition of the soaking solution. EC test determines indirectly the integrity of seed membrane systems, and is used for the assessment of seed vigor, because this test detects the seed deterioration process since its early phase. The research comprised determinations o...

  9. REDUCTION IN ELECTRICITY SUPPLIES DURING 'LIMITED POWER' PERIODS IN WINTER 1999-2000

    CERN Multimedia

    Mario Batz/TCR

    1999-01-01

    As in previous years, CERN signed contracts with EDF (Electricité de France) and with EOS (Energie Ouest Suisse), by which it undertakes, in return for special prices, to reduce its electricity consumption when the grids are at peak demand during the tariff period 'Effacement Jour de Pointe' (EJP).The contractual period for compulsory load shedding begins 1st November and ends 31st March. During these five months CERN will have to reduce its power consumption from210 MW to 40 MW during twenty-two 18-hour periods, each beginning at 7 a.m. and ending at 1 a.m. the following day. Notice will be given by EDF to the Technical Control Room (TCR) at 5 p.m. the previous day. The notice period may be reduced to two hours for days following weekends and public holidays, or omitted entirely for technical reasons.For the month of March 2000, the limit of power consumption will be increased from 40 MW to 50 MW to guarantee an easier start-up of the accelerators.During these periods, the PS complex, the SPS and ...

  10. Lessons Learned "Establishing an Electrically Safe Work Condition" Specifically related to Racking Electrical Breakers

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Tommy Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Philbert Roland [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Garcia, Samuel Anthony [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-09

    During low voltage electrical equipment maintenance, a bad breaker was identified. The breaker was racked out from the substation cubicle without following the hazardous energy control process identified in the Integrated Work Document (IWD). The IWD required the substation to be in an electrically safe work condition prior to racking the breaker. Per NFPA 70E requirements, electrical equipment shall be put into an electrically safe work condition before an employee performs work on or interacts with equipment in a manner that increases the likelihood of creating an arc flash. Racking in or out a breaker on an energized bus may increase the likelihood of creating an arc flash dependent on equipment conditions. A thorough risk assessment must be performed prior to performing such a task. The risk assessment determines the risk control measures to be put in place prior to performing the work. Electrical Safety Officers (ESO) can assist in performing risk assessments and incorporating risk control measures.

  11. Reduction of electricity comsumption during 'high cost' periods in winter 2005 - 2006

    CERN Multimedia

    Mario Batz

    2005-01-01

    In previous years CERN was able to limit its electricity consumption during the winter months sufficiently to be supplied from the Swiss grid. In order to make enough power available for the LHC machine and experiments at the lowest possible cost during the coming winter 2005 / 2006 CERN is supplied from the French grid by EDF (Electricité de France). As a consequence, when the grids are at peak demand during the tariff period 'Effacement Jour de Pointe' (EJP) in France, the energy price is at least four times as high as for the usual winter period. From 1st November until 31st March these increased prices are applicable during twenty-two 18-hour periods, each beginning at 7 a.m. and ending at 1 a.m. the following day. Notice will be given by EDF to the Technical Infrastructure Control Room (TI) at 5 p.m. the previous day. The notice period may be reduced to two hours for days following weekends and public holidays, or omitted entirely for technical reasons. During these days of EJP CERN has a strong fina...

  12. Reduction of electricity comsumption during 'high cost' periods in winter 2005 - 2006

    CERN Document Server

    Mario Batz

    2005-01-01

    In previous years CERN was able to sufficiently limit its electricity consumption during the winter months to be supplied from the Swiss grid. In order to make enough power available for the LHC machine and experiments at the lowest possible cost during the coming winter 2005 / 2006, CERN will be supplied from the French grid by EDF (Electricité de France). As a consequence, when the grids are at peak demand during the tariff period 'Effacement Jour de Pointe' (EJP) in France, the energy price is at least four times higher than for the usual winter period. From 1st November until 31st March these increased prices are applicable during twenty-two 18-hour periods, each beginning at 7 a.m. and ending at 1 a.m. the following day. Notice will be given by EDF to the Technical Infrastructure Control Room (TI) at 5 p.m. the previous day. The notice period may be reduced to two hours for days following weekends and public holidays, or omitted entirely for technical reasons. During these days of EJP CERN has a stro...

  13. Signal specific electric potential sensors for operation in noisy environments

    International Nuclear Information System (INIS)

    Beardsmore-Rust, S T; Prance, R J; Aydin, A; Prance, H; Harl, C J; Stiffell, P B

    2009-01-01

    Limitations on the performance of electric potential sensors are due to saturation caused by environmental electromagnetic noise. The work described involves tailoring the response of the sensors to reject the main components of the noise, thereby enhancing both the effective dynamic range and signal to noise. We show that by using real-time analogue signal processing it is possible to detect a human heartbeat at a distance of 40 cm from the front of a subject in an unshielded laboratory. This result has significant implications both for security sensing and biometric measurements in addition to the more obvious safety related applications.

  14. Signal specific electric potential sensors for operation in noisy environments

    Energy Technology Data Exchange (ETDEWEB)

    Beardsmore-Rust, S T; Prance, R J; Aydin, A; Prance, H; Harl, C J; Stiffell, P B, E-mail: r.j.prance@sussex.ac.u [Centre for Physical Electronics and Quantum Technology, Department of Engineering and Design, University of Sussex, Falmer, Brighton, BN1 9QT (United Kingdom)

    2009-07-01

    Limitations on the performance of electric potential sensors are due to saturation caused by environmental electromagnetic noise. The work described involves tailoring the response of the sensors to reject the main components of the noise, thereby enhancing both the effective dynamic range and signal to noise. We show that by using real-time analogue signal processing it is possible to detect a human heartbeat at a distance of 40 cm from the front of a subject in an unshielded laboratory. This result has significant implications both for security sensing and biometric measurements in addition to the more obvious safety related applications.

  15. Projection of electrical demand in Argentina for the period from 1993 through 2010 mark of economic reform

    International Nuclear Information System (INIS)

    Goni, Margarita R.; Gonzalez, Enrique

    1996-01-01

    A projection of electrical demand for two different scenarios has been presented . The period 1993-2010 is analysed and 1993 has been taken as base year. In this study MAED program was used as well as all available information from INDEC (National Statistical Body), CAMMESA (Electrical Market Company) and Ministry of Economy. The results in the base year achieved an accuracy higher than 98%. The scenarios described different rates of growth and electrical energy uses

  16. Electrical properties of phosphorene systems doped with fourth-period elements

    Science.gov (United States)

    Wang, Ke; Wang, Hai; Zhang, Min; Liu, Yan; Zhao, Wei

    2018-05-01

    In this work, we use a first-principles calculation to investigate the structure, binding energies, and electrical properties of monolayer phosphorene systems doped with fourth-period main group elements at a doping concentration of 6.25%. The calculation results reveal that, although large deformations exist, all doped systems are stable and non-spin polarized. In addition, the Ca, Se, and Br atoms are electron acceptors in the doped systems, whereas the Ga, Ge and As atoms are donors. Thus, there is an ionic bonding character between the dopants and neighboring phosphorus atoms in the Ca-, Ga-, Ge-, As-, Se-, and Br-doped systems. From band structures, we find that the K-, Ga-, As-, and Br-doped systems present semiconducting states with indirect gaps, whereas the Ca-, Ge-, and Se-doped systems have metallic states. We conclude that the metallicity of a phosphorene system doped with main-group elements depends on the number of valence electrons of the dopant. This investigation provides directions for manipulating the electrical properties of phosphorene by substitutional doping, which would broaden its possible applications in optoelectronics.

  17. VDE-specification for electrical equipment and apparatus in atmospheres endangered by explosive material

    International Nuclear Information System (INIS)

    1976-02-01

    These specifications are valid for the setting-up, changing, putting into operation and developing of electrical equipment, as well as for the application of electrical apparatus in such systems and in regions endangered by explosive materials. (orig./LH) [de

  18. Multi-Period Optimization Model for Electricity Generation Planning Considering Plug-in Hybrid Electric Vehicle Penetration

    Directory of Open Access Journals (Sweden)

    Lena Ahmadi

    2015-05-01

    Full Text Available One of the main challenges for widespread penetration of plug-in hybrid electric vehicles (PHEVs is their impact on the electricity grid. The energy sector must anticipate and prepare for this extra demand and implement long-term planning for electricity production. In this paper, the additional electricity demand on the Ontario electricity grid from charging PHEVs is incorporated into an electricity production planning model. A case study pertaining to Ontario energy planning is considered to optimize the value of the cost of the electricity over sixteen years (2014–2030. The objective function consists of the fuel costs, fixed and variable operating and maintenance costs, capital costs for new power plants, and the retrofit costs of existing power plants. Five different case studies are performed with different PHEVs penetration rates, types of new power plants, and CO2 emission constraints. Among all the cases studied, the one requiring the most new capacity, (~8748 MW, is assuming the base case with 6% reduction in CO2 in year 2018 and high PHEV penetration. The next highest one is the base case, plus considering doubled NG prices, PHEV medium penetration rate and no CO2 emissions reduction target with an increase of 34.78% in the total installed capacity in 2030. Furthermore, optimization results indicate that by not utilizing coal power stations the CO2 emissions are the lowest: ~500 tonnes compared to ~900 tonnes when coal is permitted.

  19. Design of application specific long period waveguide grating filters using adaptive particle swarm optimization algorithms

    International Nuclear Information System (INIS)

    Semwal, Girish; Rastogi, Vipul

    2014-01-01

    We present design optimization of wavelength filters based on long period waveguide gratings (LPWGs) using the adaptive particle swarm optimization (APSO) technique. We demonstrate optimization of the LPWG parameters for single-band, wide-band and dual-band rejection filters for testing the convergence of APSO algorithms. After convergence tests on the algorithms, the optimization technique has been implemented to design more complicated application specific filters such as erbium doped fiber amplifier (EDFA) amplified spontaneous emission (ASE) flattening, erbium doped waveguide amplifier (EDWA) gain flattening and pre-defined broadband rejection filters. The technique is useful for designing and optimizing the parameters of LPWGs to achieve complicated application specific spectra. (paper)

  20. Prediction of electric energy consumption in Cuba for the period 2000-2015; Pronostico del consumo de electricidad en Cuba durante el periodo 2000-2015

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Rodirguez, B [Centro Nacional de Seguridad Nuclear, La Habana (Cuba)

    1999-06-01

    This paper consists on a prediction of the growth in electric energy consumption in Cuba, for the period 2000-2015 and with respect to 1990, it also considers the specific features of the National Electroenergetic System. Validated Guidelines in accordance with the Delphi method, which incorporates the basis characteristics considered by international programs for these predictions, were used for this purpose. From the analysis of the behaviour in power consumption of the different consumers and of the expected changes in them according to the expected scenarios, a prediction on the growth in the demand of electric energy is made.

  1. Incorporating residual temperature and specific humidity in predicting weather-dependent warm-season electricity consumption

    Science.gov (United States)

    Guan, Huade; Beecham, Simon; Xu, Hanqiu; Ingleton, Greg

    2017-02-01

    Climate warming and increasing variability challenges the electricity supply in warm seasons. A good quantitative representation of the relationship between warm-season electricity consumption and weather condition provides necessary information for long-term electricity planning and short-term electricity management. In this study, an extended version of cooling degree days (ECDD) is proposed for better characterisation of this relationship. The ECDD includes temperature, residual temperature and specific humidity effects. The residual temperature is introduced for the first time to reflect the building thermal inertia effect on electricity consumption. The study is based on the electricity consumption data of four multiple-street city blocks and three office buildings. It is found that the residual temperature effect is about 20% of the current-day temperature effect at the block scale, and increases with a large variation at the building scale. Investigation of this residual temperature effect provides insight to the influence of building designs and structures on electricity consumption. The specific humidity effect appears to be more important at the building scale than at the block scale. A building with high energy performance does not necessarily have low specific humidity dependence. The new ECDD better reflects the weather dependence of electricity consumption than the conventional CDD method.

  2. Multi-period multi-objective electricity generation expansion planning problem with Monte-Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Tekiner, Hatice [Industrial Engineering, College of Engineering and Natural Sciences, Istanbul Sehir University, 2 Ahmet Bayman Rd, Istanbul (Turkey); Coit, David W. [Department of Industrial and Systems Engineering, Rutgers University, 96 Frelinghuysen Rd., Piscataway, NJ (United States); Felder, Frank A. [Edward J. Bloustein School of Planning and Public Policy, Rutgers University, Piscataway, NJ (United States)

    2010-12-15

    A new approach to the electricity generation expansion problem is proposed to minimize simultaneously multiple objectives, such as cost and air emissions, including CO{sub 2} and NO{sub x}, over a long term planning horizon. In this problem, system expansion decisions are made to select the type of power generation, such as coal, nuclear, wind, etc., where the new generation asset should be located, and at which time period expansion should take place. We are able to find a Pareto front for the multi-objective generation expansion planning problem that explicitly considers availability of the system components over the planning horizon and operational dispatching decisions. Monte-Carlo simulation is used to generate numerous scenarios based on the component availabilities and anticipated demand for energy. The problem is then formulated as a mixed integer linear program, and optimal solutions are found based on the simulated scenarios with a combined objective function considering the multiple problem objectives. The different objectives are combined using dimensionless weights and a Pareto front can be determined by varying these weights. The mathematical model is demonstrated on an example problem with interesting results indicating how expansion decisions vary depending on whether minimizing cost or minimizing greenhouse gas emissions or pollutants is given higher priority. (author)

  3. Determining Specific Window Period for Common Scab Disease Infection in Potato Tubers

    Directory of Open Access Journals (Sweden)

    Bhim Bahadur Khatri

    2017-05-01

    Full Text Available A series of experiments was conducted under glasshouse and hydroponic conditions to determine the specific window period for common scab disease infection in potato tubers. The study was performed in a glasshouse system where separate tubers from the root zone were inoculated at different intervals during plant growth along with a novel hydroponic system to inoculate individual tubers at specific times of development growth allowing non-destructive observations of common scab symptoms developing. The window of tuber susceptibility to common scab disease infection was shown to vary with the season or conditions under which the plants were grown. Different internodes on tubers were found susceptible to infection at different times during tuber development. Basal internodes, which are the first sections of the tuber to expand, were susceptible to infection in the beginning of tuber development, whereas apical internodes only became susceptible later in tuber growth when the basal internodes were no longer susceptible.

  4. Northeast regional assessment study for solar electric options in the period 1980-2000

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-04-01

    Opportunities for demonstration and large scale deployment of solar electric facilities are identified and assessed. Technical, economic, and institutional factors that can contribute to an accelerated use of solar energy for electric power generation are defined. The following topics are covered: a description of the Northeast Region and its solar resources, central station applications, a dispersed user analysis, user viewpoints and institutional factors, and market potential for dispersed solar electric systems. (MHR)

  5. Electrical spects of rainout. A preliminary survey, for period January 15, 1976--January 14, 1976

    International Nuclear Information System (INIS)

    1976-01-01

    Electrical parameters that influence the attachment of radioactive aerosol particles to cloud droplets are examined. These include the expected ambient ionization, the distribution and lifetimes of particle charge, the distribution of charge on the collecting droplets, and the magnitude of electric fields that might be present. The order of magnitude estimates obtained are used to amplify the upper bounds obtained earlier by Williams for the high electric field limit. Areas needing further study are indicated

  6. Projected costs of generating electricity from power stations for commissioning in the period 1995-2000

    International Nuclear Information System (INIS)

    1989-01-01

    The study reviews the projected electricity generation costs for the base load power generation options expected to be available in the medium term, using an agreed common economic methodology. Cost projections were obtained for nuclear and fossil fuelled plants that could in principle be commissioned in the mid-1990s, or shortly thereafter, although not all countries plan to commission plants at that time. The major changes in expectations compared with earlier studies, apart from those associated with changed perceptions of fossil fuel prices, include significantly lower nuclear investment costs for the United States, associated with an improved design and the expectation of achieving shorter construction periods than projected in the 1985 study, and generally lower nuclear fuel costs. Some countries project higher operation and maintenance costs for either coal-fired or nuclear plant or both. In the case of coal-fired plants these may be associated with the extra costs of operating desulphurisation equipment. The most marked change in nuclear operating and maintenance costs has taken place in the United States, where these costs are now expected to be twice as large as the projected nuclear fuel costs. There remain major differences in investment cost expectations between countries. The reasons for these differences have been examined in previous studies. They arise from differences in factor costs, regulatory approach, design and siting, and exchange rates which do not adequately reflect the differences in the capital investment costs between countries. In brief, most OECD countries continue to expect nuclear power to have a lower levelised generating cost than coal-fired generation when using their own technical and economic assumptions

  7. Enantiomer-specific ketorolac pharmacokinetics in young women, including pregnancy and postpartum period

    Directory of Open Access Journals (Sweden)

    Aida Kulo

    2017-02-01

    Full Text Available Racemic ketorolac clearance (CL is significantly higher at delivery, but S-ketorolac disposition determines the analgesic effects. The aim of this study was to investigate the effect of pregnancy and postpartum period on enantiomer-specific (S and R intravenous (IV ketorolac pharmacokinetics (PKs. Data in women shortly following cesarean delivery (n=39 were pooled with data in a subgroup of these women that was reevaluated in the later postpartum period (postpartum group, n=8/39 and with eight healthy female volunteers. All women received single IV bolus of 30 mg ketorolac tromethamine. Five plasma samples were collected at 1, 2, 4, 6, and 8 hours and plasma concentrations were determined using high performance liquid chromatography. Enantiomer-specific PKs were calculated using PKSolver. Unpaired analysis showed that distribution volume at steady state (Vss, L/kg for S- and R-ketorolac was significantly higher in women shortly following cesarean delivery (n=31 compared to postpartum group (n=8 or to healthy female volunteers (n=8. CL, CL to body weight, and CL to body surface area (CL/BSA for S- and R-ketorolac were also significantly higher in women following delivery. In addition, S/R-ketorolac CL/BSA ratio was significantly higher at delivery. Paired PK analysis in eight women shortly following delivery and in postpartum group showed the same pattern. Finally, the simultaneous increase in CL and Vss resulted in similar estimates for elimination half-life in both unpaired and paired analysis. In conclusion, pregnancy affects S-, R-, and S/R-ketorolac disposition. This is of clinical relevance since S-ketorolac (analgesia CL is even more increased compared to R-ketorolac CL, and S/R-ketorolac CL ratio is higher following delivery compared to postpartum period or to healthy female volunteers.

  8. Application-specific electrical characterization of high power batteries with lithium titanate anodes for electric vehicles

    International Nuclear Information System (INIS)

    Farmann, Alexander; Waag, Wladislaw; Sauer, Dirk Uwe

    2016-01-01

    This study shows results of extensive experimental measurements performed on high power lithium titanate based batteries. Characterization tests are performed over a wide temperature range (−20 °C – +40 °C) by employing electrochemical impedance spectroscopy and modified hybrid pulse power characterization tests. Furthermore, the behavior of battery impedance parameters over the battery lifetime with regard to temperature, State-of-Charge and their influence on available battery power in an example of electric vehicles is discussed. Based on extracted parameters, a reduced order equivalent circuit model considering the nonlinearity of the charge transfer resistance is parametrized. The obtained results indicate that ohmic resistance increases with decreasing State-of-Charge while the shape of the curve remains almost constant over the battery lifetime. The total impedance determined at 1 mHz shows almost no dependence on State-of-Charge and remains constant over the whole State-of-Charge range. The necessity of considering the impact of the current dependence of the direct current resistance at least at low temperatures (i.e., below 0 °C) is confirmed. Moreover, by investigating the Butler-Volmer equation the behavior of exchange current density and symmetry factor is analyzed for various temperatures and State-of-Charges over the battery lifetime. - Highlights: • Impedance characteristic over the battery lifetime is investigated. • Batteries at different aging states using lithium titanate anodes are investigated. • The influence of temperature on impedance characteristic is investigated. • Butler-Volmer behavior is comprehensively investigated under various conditions.

  9. Specification and Design of Electrical Flight System Architectures with SysML

    Science.gov (United States)

    McKelvin, Mark L., Jr.; Jimenez, Alejandro

    2012-01-01

    Modern space flight systems are required to perform more complex functions than previous generations to support space missions. This demand is driving the trend to deploy more electronics to realize system functionality. The traditional approach for the specification, design, and deployment of electrical system architectures in space flight systems includes the use of informal definitions and descriptions that are often embedded within loosely coupled but highly interdependent design documents. Traditional methods become inefficient to cope with increasing system complexity, evolving requirements, and the ability to meet project budget and time constraints. Thus, there is a need for more rigorous methods to capture the relevant information about the electrical system architecture as the design evolves. In this work, we propose a model-centric approach to support the specification and design of electrical flight system architectures using the System Modeling Language (SysML). In our approach, we develop a domain specific language for specifying electrical system architectures, and we propose a design flow for the specification and design of electrical interfaces. Our approach is applied to a practical flight system.

  10. A species-specific nucleosomal signature defines a periodic distribution of amino acids in proteins.

    Science.gov (United States)

    Quintales, Luis; Soriano, Ignacio; Vázquez, Enrique; Segurado, Mónica; Antequera, Francisco

    2015-04-01

    Nucleosomes are the basic structural units of chromatin. Most of the yeast genome is organized in a pattern of positioned nucleosomes that is stably maintained under a wide range of physiological conditions. In this work, we have searched for sequence determinants associated with positioned nucleosomes in four species of fission and budding yeasts. We show that mononucleosomal DNA follows a highly structured base composition pattern, which differs among species despite the high degree of histone conservation. These nucleosomal signatures are present in transcribed and non-transcribed regions across the genome. In the case of open reading frames, they correctly predict the relative distribution of codons on mononucleosomal DNA, and they also determine a periodicity in the average distribution of amino acids along the proteins. These results establish a direct and species-specific connection between the position of each codon around the histone octamer and protein composition.

  11. Age-specific mortality trends in France and Italy since 1900: period and cohort effects.

    Science.gov (United States)

    Caselli, G; Vallin, J; Vaupel, J W; Yashin, A

    1987-11-01

    The age/sex-specific mortality trends of France and Italy were studied over the 1899-1979 period in as much detail as possible in an effort to distinguish between cohort effects and those related to period changes. Complete series of mortality data by individual years of age and calendar years were available from 1869 to 1979 for Italy and from 1899 to 1982 for France. For both countries, these data include the military and civil deaths not registered in vital statistics during the war periods. They cover each national territory as defined by its present boundaries. The graphical representation method of mortality surfaces, elaborated by Vaupel, Gambill, and Yashin (1985), was adopted. The age/sex-specific mortality patterns of France and Italy have not followed the same trends, and the differences observed today are not those of 100 years ago. The mean death probabilities for the 1975-79 period were used to illustrate the age-specific patterns of mortality. Although infant mortality was higher in Italy than in France, the death probabilities at ages 1-15 for both sexes were roughly the same for both countries. At ages 15-23, they were much higher in France than in Italy, and they remained considerably higher in France up to age 55. From then on, the sexes differ: for males, the 2 countries showed similar patterns, whereas for females the probabilities were noticeably higher for France. The situation was very different for both countries at the beginning of the century. For both sexes, higher mortality was observed in Italy not only during infancy but throughout childhood and the adolescent years up to age 15. The 2 countries showed similar patterns from 15-25. Above age 25, the 2 countries had similar patterns for females, whereas male mortality was higher in France right up to the old age groups. Such differences in the age-specific mortality trends depend in part on a different development of health and social conditions but also may be due to factors concerning

  12. Region-specific study of the electric utility industry: problem identification, analysis, and recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Pochan, M.J.

    1985-07-01

    A number of problems were identified that could stand in the way of maintaining an adequate, reliable and economic supply of electric power for the United States in the future. The problems were analyzed by studying a specific region, VACAR (Virginia-Carolinas), in some detail. It was concluded that the future power supply is in jeopardy, but that drastic changes in the present system of investor-owned utilities, specifically, deregulation or government ownership, were not justified. It was recommended that the present electric system be modified and strengthened to meet future needs. 2 refs., 8 figs., 15 tabs.

  13. Region-specific study of the electric utility industry: problem identification, analysis, and recommendations

    International Nuclear Information System (INIS)

    Pochan, M.J.

    1985-07-01

    A number of problems were identified that could stand in the way of maintaining an adequate, reliable and economic supply of electric power for the United States in the future. The problems were analyzed by studying a specific region, VACAR (Virginia-Carolinas), in some detail. It was concluded that the future power supply is in jeopardy, but that drastic changes in the present system of investor-owned utilities, specifically, deregulation or government ownership, were not justified. It was recommended that the present electric system be modified and strengthened to meet future needs. 2 refs., 8 figs., 15 tabs

  14. The Myotonic Plot Thickens: Electrical Myotonia in Antimuscle-Specific Kinase Myasthenia Gravis

    Directory of Open Access Journals (Sweden)

    Marcus Magnussen

    2015-01-01

    Full Text Available Electrical myotonia is known to occur in a number of inherited and acquired disorders including myotonic dystrophies, channelopathies, and metabolic, toxic, and inflammatory myopathies. Yet, electrical myotonia in myasthenia gravis associated with antibodies against muscle-specific tyrosine kinase (MuSK has not been previously reported. We describe two such patients, both of whom had a typical presentation of proximal muscle weakness with respiratory failure in the context of a significant electrodecrement in repetitive nerve stimulation. In both cases, concentric needle examination revealed electrical myotonia combined with myopathic motor unit morphology and early recruitment. These findings suggest that MuSK myasthenia should be included within the differential diagnosis of disorders with electrical myotonia.

  15. Guidelines for price cap regulation in the Dutch electricity sector for the period 2000-2003

    International Nuclear Information System (INIS)

    Burns, P.; Newbery, D.; Tjin, T.; Verdonkschot, I.; Buitelaar, T.; Van Gent, C.

    2000-02-01

    July 1999 The Netherlands Electricity Regulatory Service (DtE) published an Information and Consultation Document on the title subject. By means of price cap regulation tariffs are determined such that businesses are stimulated continuously to organize their total processes and operation as efficient as possible. In the consultation document a large number of questions with respect to the future organization and planning of the system of economic regulation of the electricity sector in the Netherlands can be found. Many reactions and answers were received, compiled and analyzed. The results are presented in this report, which forms the framework for the DtE to shape the economic regulation of the Dutch electricity sector

  16. Managing electrical demand through difficult periods: California's experience with demand response

    International Nuclear Information System (INIS)

    Wikler, G.; Ghosh, D.Ph.D.

    2010-01-01

    This paper provides a brief overview of California's electricity situation and the relevance of Demand Response (DR) in addressing some of the challenges faced by the State's electricity system. It then discusses California's experience with DR, market rules that influence what role DR plays and attempts to integrate wholesale-retail level program offerings in the State, and some of the key drivers that are likely to enhance the role of DR. Lastly, the paper identifies some of the key challenges facing implementers of DR programs and discusses how many of those challenges could potentially be overcome. (authors)

  17. Energy, electricity and nuclear power estimates for the period up to 2020. Jul 1998 ed.

    International Nuclear Information System (INIS)

    1998-01-01

    Reference Data Series No. 1 is an annual publication - currently in its eighteenth edition - containing estimates of energy, electricity and nuclear power trends up to the year 2020. The time horizon covered in the previous editions was up to 2015. (author)

  18. HIGHLY RESOLVED MEASUREMENTS OF PERIODIC RADIAL ELECTRIC FIELD AND ASSOCIATED RELAXATIONS IN EDGE BIASING EXPERIMENTS

    Czech Academy of Sciences Publication Activity Database

    Peleman, P.; Xu, Y.; Spolaore, M.; Brotánková, Jana; Devynck, P.; Stöckel, Jan; Van Oost, G.; Boucher, C.

    363-365, č. 17 (2007), s. 638-642 ISSN 0022-3115. [ Plasma Surface Interactions in Controlled Fusion Devices/17th./. Hefei, 22.05.2007-26.05.2007] Institutional research plan: CEZ:AV0Z20430508 Keywords : Relaxations * Edge transport * Plasma flow * Radial electric fields Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.643, year: 2007

  19. Energy, electricity and nuclear power estimates for the period up to 2020. July 2002 ed

    International Nuclear Information System (INIS)

    2002-01-01

    Reference Data Series No. 1 is an annual publication - currently in its twenty-second edition - containing estimates of energy, electricity and nuclear power trends up to the year 2020. Nuclear data presented in Table 1 are based on actual statistical data collected by the IAEA's Power Reactor Information System (PRIS). Energy and electricity data for 2001, however, are estimated, since the latest available information from the Department of Economic and Social Affairs of the United Nations is for 1999. Population data originate from the 'World Population Prospects' (2001 Revision), published by the Population Division of the UN Department of Economic and Social Affairs, and the 2001 values are estimates. The future growth of energy, electricity and nuclear power up to the year 2020 is presented as low and high estimates in order to encompass the uncertainties associated with the future. These estimates should be viewed as very general growth trends whose validity must constantly be subjected to critical review. The nuclear generating capacity estimates presented in Table 3 are derived from a country by country bottom-up approach. They are established by a group of experts participating each year in the IAEA's consultancy on Nuclear Capacity Projections and based upon a review of nuclear power projects and programmes in Member States. The total energy consumption has been calculated by summing the primary energy consumption and the net secondary energy import. The values shown in Table 9 refer to primary energy consumed for the generation of electricity. Owing to differences in conversion efficiencies, the percentage values are different from the shares of electricity generation presented in Tables 1 and 5

  20. Weak interactions in Graphane/BN systems under static electric fields—A periodic ab-initio study.

    Science.gov (United States)

    Steinkasserer, Lukas Eugen Marsoner; Gaston, Nicola; Paulus, Beate

    2015-04-21

    Ab-initio calculations via periodic Hartree-Fock (HF) and local second-order Møller-Plesset perturbation theory (LMP2) are used to investigate the adsorption properties of combined Graphane/boron nitride systems and their response to static electric fields. It is shown how the latter can be used to alter both structural as well as electronic properties of these systems.

  1. Energy, electricity and nuclear power estimates for the period up to 2030. 2007 ed

    International Nuclear Information System (INIS)

    2007-01-01

    Reference Data Series No. 1 is an annual publication - currently in its twenty-seventh edition - containing estimates of energy, electricity and nuclear power trends up to the year 2030. Nuclear data presented are based on actual statistical data collected by the IAEA's Power Reactor Information System (PRIS). Energy and electricity data for 2006, however, are estimated, since the latest available information from the Department of Economic and Social Affairs of the United Nations is for 2004. Population data originate from the World Population Prospects (2003 Revision), published by the Population Division of the UN Department of Economic and Social Affairs, and the 2005 values are estimates. The future growth of energy, electricity and nuclear power up to the year 2030 is presented as low and high estimates in order to encompass the uncertainties associated with the future. These estimates should be viewed as very general growth trends whose validity must constantly be subjected to critical review. The energy forecasts carried out in increasing numbers over the last years by international, national and private organizations are based on a multiplicity of different assumptions and different aggregating procedures, which make their comparison and synthesis very difficult. The basic differences refer to such fundamental input data as: - World and regional scenarios of economic development; - Correlation of economic growth and energy consumption; - Assumptions on physical, economic and political constraints applying to energy production and consumption; - Future prices of different energy sources. The projections presented in this booklet are based on a compromise among: - National projections supplied by each country for a recent OECD/NEA study; - Indicators of development published by the World Bank in its World Development Indicators; - Estimates of energy, electricity and nuclear power growth continuously carried out by the IAEA in the wake of recent global and

  2. Bloch electrons in 2D periodic electric and magnetic fields; Bloch-Elektronen in 2D periodischen elektrischen und magnetischen Feldern

    Energy Technology Data Exchange (ETDEWEB)

    Naundorf, B.

    2001-06-01

    The following topics were dealt with: electrons in periodic potentials, Bloch states, Landau states, wave packets, Harper equation, uncoupled Landau band states, matrix elements and matrix equations, periodic electric and magnetic fields (WL)

  3. Magnetic and electric stimulation to elicit the masseteric exteroceptive suppression period

    DEFF Research Database (Denmark)

    Komiyama, Osamu; Wang, Kelun; Svensson, Peter

    2010-01-01

    : In contrast to electrical stimulation, both ES1 and ES2 appeared and saturated with painless magnetic stimuli. SIGNIFICANCE: The present results indicate that both ES1 and ES2 have a non-nociceptive origin. Painless magnetic stimuli will be an advantage in ES reflex examinations for various orofacial pain......OBJECTIVES: The present study compared the perception of electric and magnetic stimuli for reflex appearance threshold (RT) and reflex saturation threshold (RS) of the exteroceptive suppression reflex (ES) in the masseter muscle. METHODS: Twelve healthy males and 12 females (age: 24.2+/-3.2 years......) participated. The surface EMG was recorded from the left masseter muscle. The stimulus intensities were set as multiple values of the sensory threshold (ST), and were applied to the skin above the left mental nerve. Subjects reported the perceived intensity of the stimulus on a numeric rating scale (NRS) at RT...

  4. Energy, Electricity and Nuclear Power Estimates for the Period up to 2050. 2012 Ed

    International Nuclear Information System (INIS)

    2012-01-01

    Reference Data Series No. 1 (RDS-1) is an annual publication - currently in its thirty-second edition - containing estimates of energy, electricity and nuclear power trends up to the year 2050. RDS-1 starts with a summary of the situation of nuclear power in IAEA Member States as of the end of 2011. The data on nuclear power presented in Tables 1 and 2 are based on actual statistical data collected by the IAEA's power Reactor Information System (pRIS). however, energy and electricity data for 2011 are estimated, as the latest information available from the united Nations Department of Economic and Social Affairs is for 2009 only. population data originate from the world population prospects (2010 revision), published by the population Division of the united Nations Department of Economic and Social Affairs. The 2011 values again are estimates. As in previous editions, projections of future energy and electricity demand and the role of nuclear power are presented as low and high estimates encompassing the inherent uncertainties involved in projecting trends. The RDS-1 estimates should be viewed as very general growth trends whose validity must be constantly subjected to critical review. Many international, national and private organizations routinely engage in energy demand and supply projections, including nuclear power. These projections are based on a multitude of different assumptions and aggregating procedures, which make a straightforward comparison and synthesis very difficult. The basic differences refer to such fundamental input assumptions as: - Economic growth; - Correlation of economic growth and energy use; -Technology performance and costs; - Energy resource availability and future fuel prices; - Energy policy and physical, environmental and economic constraints. The projections presented in this publication are based on a compromise between: - National projections supplied by each country for a recent OECD/NEA study; - Indicators of development

  5. Technical efficiency of Spanish electrical sector: analysis of 1998-2001 period

    International Nuclear Information System (INIS)

    Gutierrez Moya, E.; Arevalo Quijada, M. T.

    2007-01-01

    The aim of this article is to analyse the technical efficiency of the energy Spanish sector in the course of the stage of liberalization (1998-2001). The study uses the non parametric approach of DEA (Data Envelopment Analysis) to derive Malaquist productivity indexes. In the study there is revealed the improvement of productivity of the mentioned companies, as well as the major differentiation between electrical considered companies. (Author) 23 refs

  6. Energy, electricity and nuclear power estimates for the period up to 2030. 2008 ed

    International Nuclear Information System (INIS)

    2008-01-01

    Reference Data Series No. 1 is an annual publication containing estimates of energy, electricity and nuclear power trends up to the year 2030. The future growth of energy, electricity and nuclear power up to the year 2030 is presented as low and high estimates in order to encompass the uncertainties associated with the future. These estimates should be viewed as very general growth trends whose validity must constantly be subjected to critical review. The energy forecasts carried out in increasing numbers over the last years by international, national and private organizations are based on a multiplicity of different assumptions and different aggregating procedures, which make their comparison and synthesis very difficult.The basic differences refer to such fundamental input data as: World and regional scenarios of economic development; Correlation of economic growth and energy consumption; Assumptions on physical, economic and political constraints applying to energy production and consumption; Future prices of different energy sources. The projections presented in this booklet are based on a compromise among: National projections supplied by each country for a recent OECD/NEA study; Indicators of development published by the World Bank in its World Development Indicators; Estimates of energy, electricity and nuclear power growth continuously carried out by the IAEA in the wake of recent global and regional projections made by other international organizations

  7. Energy, electricity and nuclear power estimates for the period up to 2030. July 2003 ed

    International Nuclear Information System (INIS)

    2003-01-01

    Reference Data Series No. 1 is an annual publication - currently in its twenty-second edition - containing estimates of energy, electricity and nuclear power trends up to the year 2020. Nuclear data presented in Table 1 are based on actual statistical data collected by the IAEA's Power Reactor Information System (PRIS). Energy and electricity data for 2001, however, are estimated, since the latest available information from the Department of Economic and Social Affairs of the United Nations is for 1999. Population data originate from the 'World Population Prospects' (2001 Revision), published by the Population Division of the UN Department of Economic and Social Affairs, and the 2001 values are estimates. The future growth of energy, electricity and nuclear power up to the year 2020 is presented as low and high estimates in order to encompass the uncertainties associated with the future. These estimates should be viewed as very general growth trends whose validity must constantly be subjected to critical review. The nuclear generating capacity estimates presented in Table are derived from a country by country bottom-up approach. They are established by a group of experts participating each year in the IAEA's consultancy on Nuclear Capacity Projections and based upon a review of nuclear power projects and programmes in Member States. The total energy consumption has been calculated by summing the primary energy consumption and the net secondary energy import

  8. Energy, Electricity and Nuclear Power Estimates for the Period up to 2030. 2009 Ed

    International Nuclear Information System (INIS)

    2009-01-01

    Reference Data Series No. 1 is an annual publication - currently in its twenty-ninth edition - containing estimates of energy, electricity and nuclear power trends up to the year 2030. The future growth of energy, electricity and nuclear power up to the year 2030 is presented as low and high estimates in order to encompass the uncertainties associated with the future. These estimates should be viewed as very general growth trends whose validity must constantly be subjected to critical review. The energy forecasts carried out in increasing numbers over the last years by international, national and private organizations are based on a multiplicity of different assumptions and different aggregating procedures, which make their comparison and synthesis very difficult. The basic differences refer to such fundamental input data as: - World and regional scenarios of economic development; - Correlation of economic growth and energy consumption; - Assumptions on physical, economic and political constraints applying to energy production and consumption; - Future prices of different energy sources. The projections presented in this booklet are based on a compromise among: - National projections supplied by each country for a recent OECD/NEA study; - Indicators of development published by the World Bank in its World Development Indicators; - Estimates of energy, electricity and nuclear power growth continuously carried out by the IAEA in the wake of recent global and regional projections made by other international organizations

  9. Energy, Electricity and Nuclear Power Estimates for the Period up to 2050. 2017 Ed

    International Nuclear Information System (INIS)

    2017-01-01

    Reference Data Series No. 1 (RDS-1) is an annual publication — currently in its thirty-seventh edition — containing estimates of energy, electricity and nuclear power trends up to the year 2050. RDS-1 starts with a summary of the status of nuclear power in IAEA Member States as of the end of 2016 based on statistical data collected by the IAEA’s Power Reactor Information System (PRIS). It then presents estimates of energy and electricity up to 2050 derived from various international studies, including the International Energy Agency’s World Energy Outlook 2016 and the United States Energy Information Administration’s International Energy Outlook 2016. The energy and electricity data for 2016 are estimated, as the latest information available from the United Nations Department of Economic and Social Affairs is for 2014. Population data originate from World Population Prospects (2015 revision), published by the Population Division of the United Nations Department of Economic and Social Affairs. The 2016 values again are estimates. As in previous editions of RDS-1, projections of nuclear power are presented as low and high estimates encompassing the uncertainties inherent in projecting trends. The projections are based on a critical review of (i) the global and regional energy, electricity and nuclear power projections made by other international organizations, (ii) national projections supplied by individual countries for a recent OECD Nuclear Energy Agency study and (iii) the estimates of the expert group participating in the IAEA’s yearly consultancy on nuclear capacity projections. The low and high estimates reflect contrasting, but not extreme, underlying assumptions on the different driving factors that have an impact on nuclear power deployment. These factors, and the ways they might evolve, vary from country to country. The estimates presented provide a plausible range of nuclear capacity growth by region and worldwide. They are not intended to be

  10. Muscle fiber type specific induction of slow myosin heavy chain 2 gene expression by electrical stimulation

    International Nuclear Information System (INIS)

    Crew, Jennifer R.; Falzari, Kanakeshwari; DiMario, Joseph X.

    2010-01-01

    Vertebrate skeletal muscle fiber types are defined by a broad array of differentially expressed contractile and metabolic protein genes. The mechanisms that establish and maintain these different fiber types vary throughout development and with changing functional demand. Chicken skeletal muscle fibers can be generally categorized as fast and fast/slow based on expression of the slow myosin heavy chain 2 (MyHC2) gene in fast/slow muscle fibers. To investigate the cellular and molecular mechanisms that control fiber type formation in secondary or fetal muscle fibers, myoblasts from the fast pectoralis major (PM) and fast/slow medial adductor (MA) muscles were isolated, allowed to differentiate in vitro, and electrically stimulated. MA muscle fibers were induced to express the slow MyHC2 gene by electrical stimulation, whereas PM muscle fibers did not express the slow MyHC2 gene under identical stimulation conditions. However, PM muscle fibers did express the slow MyHC2 gene when electrical stimulation was combined with inhibition of inositol triphosphate receptor (IP3R) activity. Electrical stimulation was sufficient to increase nuclear localization of expressed nuclear-factor-of-activated-T-cells (NFAT), NFAT-mediated transcription, and slow MyHC2 promoter activity in MA muscle fibers. In contrast, both electrical stimulation and inhibitors of IP3R activity were required for these effects in PM muscle fibers. Electrical stimulation also increased levels of peroxisome-proliferator-activated receptor-γ co-activator-1 (PGC-1α) protein in PM and MA muscle fibers. These results indicate that MA muscle fibers can be induced by electrical stimulation to express the slow MyHC2 gene and that fast PM muscle fibers are refractory to stimulation-induced slow MyHC2 gene expression due to fast PM muscle fiber specific cellular mechanisms involving IP3R activity.

  11. Specific features in the behavior of electrical resistivity of the pine biocarbon preform/copper composite

    Science.gov (United States)

    Burkov, A. T.; Orlova, T. S.; Smirnov, B. I.; Smirnov, I. A.; Misiorek, H.; Jezowski, A.

    2010-11-01

    The electrical resistivity ρ( T) of the novel type of composites prepared by infiltrating melted copper in vacuum in empty sap channels of white pine high-porosity biocarbon preforms has been measured in the temperature range 5-300 K. Biocarbon preforms have been prepared by pyrolysis of tree wood in an argon flow at two carbonization temperatures, 1000 and 2400°C. The electrical resistivity of the composites has been found to vary relatively weakly with temperature and to pass through a characteristic minimum near 40-50 K, which can be ascribed to iron and manganese impurities penetrating into copper from the carbon preform when liquid copper is infiltrated into it. It has been shown that the electrical resistivity ρ( T) of the composites is governed primarily by the specific microstructure of the preform, which is made up of parallel channels with an average diameter of about 50 μm interrupted by systems of thin capillaries. The small cross section of the copper-filled capillaries accounts for these regions providing the major contribution to the electrical resistivity of the composites. An increase in the wood carbonization temperature brings about a noticeable increase in the effective capillary cross section and a decrease in the electrical resistivity ρ( T) of the composite.

  12. Energy, electricity and nuclear power estimates for the period up to 2020. July 2001 ed

    International Nuclear Information System (INIS)

    2001-01-01

    Reference Data Series No. 1 is an annual publication, currently in its twenty-first edition, containing estimates of energy, electricity and nuclear power trends up to the year 2020. Nuclear data presented are based on actual statistical data collected by the IAEA Power Reactor Information System (PRIS). Energy and electricity data for 2000, however, are estimated, since the latest available information from the Department of Economic and Social Affairs of the United Nations is for 1998. Population data originate from the 'World Population Prospects' (1999 Revision), published by the Population Division of the UN Department of Economic and Social Affairs, and the 2000 values are estimates. The future growth of energy, electricity and nuclear power up to the year 2020 is presented as low and high estimates in order to encompass the uncertainties associated with the future. These estimates should be viewed as very general growth trends whose validity must constantly be subjected to critical review. The energy forecasts carried out in increasing numbers over the last years by international, national and private organizations are based on a multiplicity of different assumptions and different aggregating procedures, which make their comparison and synthesis very difficult. The basic differences refer to such fundamental input data as: World and regional scenarios of economic development; Correlation of economic growth and energy consumption; Assumptions on physical, economic and political constraints applying to energy production and consumption; Future prices of different energy sources. The projections presented in this booklet are based on a compromise among: National projections supplied by each country for a recent OECD NEA study; Indicators of development published by the World Bank in its World Development Indicators; Estimates of energy, electricity and nuclear power growth continuously carried out by the IAEA in the wake of recent global and regional

  13. Results of evaluation of periodic safety review for No. 1 plant in Mihama Power Station, Kansai Electric Power Co., Inc

    International Nuclear Information System (INIS)

    1994-01-01

    No. 1 plant in Mihama Power Station started the commercial power generation in November, 1970, and has continued the operation for more than 23 years. During this period, the counter measures to troubles, periodic inspections and the maintenance by the electric power company have been carried out. These states of No. 1 plant in Mihama Power Station for more than 23 years are to be recollected from the view-points of the comprehensive evaluation of operation experiences and the reflection of latest technological knowledge, and the safety and reliability are to be further improved in the periodic safety review. Agency of Natural Resources and Energy evaluated the report of the periodic safety review for No. 1 plant in Mihama Power Station made by Kansai Electric Power Co., and summarized the results. The course of the evaluation of the report is shown. The facility utilization factor is 43.3% on the average of about 23 years, but in the last 10 years, it was improved to 69.4%. In the last five years, the rate of occurrence of unexpected shutoff was 0.6 times/year. These are the results of preventive maintenance and the improvement of the facilities and operation management. Operation management, maintenance management, fuel management, radiation control, and radioactive waste management have been carried out properly. The work plan for preventing disasters was established, and the experience of troubles and the latest technological knowledge were well reflected to improve the safety. (K.I.)

  14. Energy, Electricity and Nuclear Power Estimates for the Period up to 2050. 2013 Ed

    International Nuclear Information System (INIS)

    2013-01-01

    Reference Data Series No. 1 (RDS-1) is an annual publication - currently in its thirty-third edition - containing estimates of energy, electricity and nuclear power trends up to the year 2050. RDS-1 starts with a summary of the situation of nuclear power in IAEA Member States as of the end of 2012. The data on nuclear power presented are based on actual statistical data collected by the IAEA's power Reactor Information System (PRIS). However, energy and electricity data for 2012 are estimated, as the latest information available from the united Nations Department of Economic and Social Affairs is for 2010 only. Population data originate from the world population prospects (2010 revision), published by the population Division of the united Nations Department of Economic and Social Affairs. The 2012 values again are estimates. As in previous editions, projections of future energy and electricity demand and the role of nuclear power are presented as low and high estimates encompassing the inherent uncertainties involved in projecting trends. The RDS-1 estimates should be viewed as very general growth trends whose validity must be constantly subjected to critical review. Many international, national and private organizations routinely engage in energy demand and supply projections, including nuclear power. These projections are based on a multitude of different assumptions and aggregating procedures, which make a straightforward comparison and synthesis very difficult. The basic differences refer to such fundamental input assumptions as: - Economic growth; - Correlation of economic growth and energy use; - Technology performance and costs; - Energy resource availability and future fuel prices; - Energy policy and physical, environmental and economic constraints

  15. Energy, Electricity and Nuclear Power Estimates for the Period up to 2050. 2016 Ed

    International Nuclear Information System (INIS)

    2016-01-01

    Reference Data Series No. 1 (RDS-1) is an annual publication — currently in its thirty-sixth edition — containing estimates of energy, electricity and nuclear power trends up to the year 2050. RDS-1 starts with a summary of the situation of nuclear power in IAEA Member States as of the end of 2015. The data on nuclear power presented in Tables 1 and 2 are based on actual statistical data collected by the IAEA’s Power Reactor Information System (PRIS). However, energy and electricity data for 2015 are estimated, as the latest information available from the United Nations Department of Economic and Social Affairs is for 2013. Population data originate from the World Population Prospects (2012 revision), published by the Population Division of the United Nations Department of Economic and Social Affairs. The 2015 values again are estimates. As in previous editions, projections of future energy and electricity demand and the role of nuclear power are presented as low and high estimates encompassing the inherent uncertainties involved in projecting trends. The RDS-1 estimates should be viewed as very general growth trends whose validity must be constantly subjected to critical review. Many international, national and private organizations routinely engage in energy demand and supply projections, including projections for nuclear power. These projections are based on a multitude of different assumptions and aggregating procedures, making a straightforward comparison and synthesis very difficult. The basic differences relate to such fundamental input assumptions as: • Economic growth; • Correlation of economic growth and energy use; • Technology performance and costs; • Energy resource availability and future fuel prices; •• Energy policy and physical, environmental and economic constraints

  16. Energy, Electricity and Nuclear Power Estimates for the Period up to 2050. 2014 Ed

    International Nuclear Information System (INIS)

    2014-01-01

    Reference Data Series No. 1 (RDS-1) is an annual publication — currently in its thirty-fourth edition — containing estimates of energy, electricity and nuclear power trends up to the year 2050. RDS-1 starts with a summary of the situation of nuclear power in IAEA Member States as of the end of 2013. The data on nuclear power presented in Tables 1 and 2 are based on actual statistical data collected by the IAEA’s Power Reactor Information System (PRIS). However, energy and electricity data for 2013 are estimated, as the latest information available from the United Nations Department of Economic and Social Affairs is for 2011. Population data originate from the World Population Prospects (2010 revision), published by the Population Division of the United Nations Department of Economic and Social Affairs. The 2013 values again are estimates. As in previous editions, projections of future energy and electricity demand and the role of nuclear power are presented as low and high estimates encompassing the inherent uncertainties involved in projecting trends. The RDS-1 estimates should be viewed as very general growth trends whose validity must be constantly subjected to critical review. Many international, national and private organizations routinely engage in energy demand and supply projections, including nuclear power. These projections are based on a multitude of different assumptions and aggregating procedures, making a straightforward comparison and synthesis very difficult. The basic differences relate to such fundamental input assumptions as: • Economic growth; • Correlation of economic growth and energy use; • Technology performance and costs; • Energy resource availability and future fuel prices; • Energy policy and physical, environmental and economic constraints

  17. Energy, Electricity and Nuclear Power Estimates for the Period up to 2050. 2010 Ed

    International Nuclear Information System (INIS)

    2010-01-01

    Reference Data Series No. 1 (RDS-1) is an annual publication - currently in its thirtieth edition - containing estimates of energy, electricity and nuclear power trends up to the year 2050. RDS-1 starts with a summary of the situation of nuclear power in IAEA Member States as of the end of 2009. The data on nuclear power are based on actual statistical data collected by the IAEA's Power Reactor Information System (PRIS). Energy and electricity data for 2009, however, are estimated, since the latest available information from the United Nations Department of Economic and Social Affairs is for 2007. Population data originate from the World Population Prospects (2008 revision), published by the Population Division of the United Nations Department of Economic and Social Affairs, and the 2009 values again are estimates. As in the past, projections of future needs of energy, electricity and nuclear power are presented as low and high estimates encompassing the inherent uncertainties involved in projecting trends. The RDS-1 estimates should be viewed as very general growth trends whose validity must be constantly subjected to critical review. Beginning with the 30th edition of this publication, however, the end-point of the estimates is extended up to the year 2050 (instead of 2030). Looking beyond 2030 is prompted by the interest expressed by numerous Member States currently without nuclear power in adding nuclear energy to their future national energy supply mixes. Given the lead times in planning and implementing nuclear power programmes, a fair share of these are likely to result in actual plant commissioning and grid connection after 2030. Many international, national and private organizations routinely engage in energy demand and supply projections, including nuclear power. These projections are based on a multitude of different assumptions and aggregating procedures, which make a straightforward comparison and synthesis very difficult. The basic differences refer

  18. Technical Specifications, Comanche Peak Steam Electric Station, Unit 1 (Docket No. 50-445)

    International Nuclear Information System (INIS)

    1990-04-01

    The Technical Specifications for Comanche Peak Steam Electric Station, Unit 1 were prepared by the US Nuclear Regulatory Commission. They set forth the limits, operating conditions, and other requirements applicable to a nuclear reactor facility, as set forth in Section 50.36 of Title 10 of the Code of Federal Regulations Part 50, for the protection of the health and safety of the public

  19. Energy, electricity and nuclear power estimates for the period up to 2030. July 2005 ed

    International Nuclear Information System (INIS)

    2005-01-01

    Reference Data Series No. 1 is an annual publication - currently in its twenty-fifth edition - containing estimates of energy, electricity and nuclear power trends up to the year 2030. Nuclear data presented in Table 1 are based on actual statistical data collected by the IAEA's Power Reactor Information System (PRIS). Energy and electricity data for 2004, however, are estimated, since the latest available information from the Department of Economic and Social Affairs of the United Nations is for 2002. Population data originate from the 'World Population Prospects' (2003 Revision), published by the Population Division of the UN Department of Economic and Social Affairs, and the 2004 values are estimates. The future growth of energy, electricity and nuclear power up to the year 2030 is presented as low and high estimates in order to encompass the uncertainties associated with the future. These estimates should be viewed as very general growth trends whose validity must constantly be subjected to critical review. The energy forecasts carried out in increasing numbers over the last years by international, national and private organizations are based on a multiplicity of different assumptions and different aggregating procedures, which make their comparison and synthesis very difficult. The basic differences refer to such fundamental input data as: - World and regional scenarios of economic development; - Correlation of economic growth and energy consumption; - Assumptions on physical, economic and political constraints applying to energy production and consumption; - Future prices of different energy sources. The projections presented in this booklet are based on a compromise among: - National projections supplied by each country for a recent OECD/NEA study; - Indicators of development published by the World Bank in its World Development Indicators; - Estimates of energy, electricity and nuclear power growth continuously carried out by the IAEA in the wake of recent

  20. A glucose concentration and temperature sensor based on long period fiber gratings induced by electric-arc discharge

    Science.gov (United States)

    Du, Chao; Wang, Qi

    2017-10-01

    As one of the key parameters in biological and chemical reactions, glucose concentration objectively reflects the characteristics of reactions, so the real-time monitoring of glucose concentration is important in the field of biochemical. Meanwhile, the influence from temperature should be considered. The fiber sensors have been studied extensively for decades due to the advantages of small size, immunity to electromagnetic interference and high sensitivity, which are suitable for the application of biochemical sensing. A long period fiber grating (LPFG) sensor induced by electric-arc discharge has been fabricated and demonstrated for simultaneous measurement of glucose concentration and temperature. The proposed sensor was fabricated by inscribing a sing mode fiber (SMF) with periodic electric-arc discharge technology. During the fabrication process, the electric-arc discharge technology was produced by a commercial fusion splicer, and the period of inscribed LPFG was determined by the movement of translation stages. A serials of periodic geometrical deformations would be formed in SMF after the fabrication, and the discharge intensity and discharge time can be adjusted though the fusion splicer settings screen. The core mode can be coupled into the cladding modes at certain wavelength when they satisfy the phase-matching conditions, and there will be several resonance dips in the transmission spectrum in LPFG. The resonance dips formed by the coupling between cladding modes and core mode have different sensitivity responses, so the simultaneous measurement for multi-parameter can be realized by monitoring the wavelength shifts of the resonance dips. Compared with the LPFG based on conventional SMF, the glucose concentration sensitivity has been obviously enhanced by etching the cladding with hydrofluoric acid solution. Based on the independent measured results, a dual-parameter measurement matrix has been built for signal demodulation. Because of the easy

  1. Effect of electric field on the performance of soil electro-bioremediation with a periodic polarity reversal strategy.

    Science.gov (United States)

    Mena, E; Villaseñor, J; Cañizares, P; Rodrigo, M A

    2016-03-01

    In this work, it is studied the effect of the electric fields (within the range 0.0-1.5 V cm(-1)) on the performance of electrobioremediation with polarity reversal, using a bench scale plant with diesel-spiked kaolinite with 14-d long tests. Results obtained show that the periodic changes in the polarity of the electric field results in a more efficient treatment as compared with the single electro-bioremediation process, and it does not require the addition of a buffer to keep the pH within a suitable range. The soil heating was not very important and it did not cause a change in the temperature of the soil up to values incompatible with the life of microorganisms. Low values of water transported by the electro-osmosis process were attained with this strategy. After only 14 d of treatment, by using the highest electric field studied in this work (1.5 V cm(-1)), up to 35.40% of the diesel added at the beginning of the test was removed, value much higher than the 10.5% obtained by the single bioremediation technology in the same period. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Electric response of an electrolytic cell to a periodic excitation in the dc limit

    International Nuclear Information System (INIS)

    Alexe-Ionescu, A.L.; Barbero, G.; Duarte, A.R.; Saracco, G.

    2014-01-01

    We evaluate the electrical impedance of an electrolytic cell submitted to a low frequency external voltage. We show that in the limit where the circular frequency of the applied voltage, ω, is small with respect to Debye relaxation circular frequency, ω D , the response of the cell can be evaluated by means of a perturbational calculation, where the expansion parameter is x=ω/ω D . Simple expressions for the reactance and resistance in the dc limit of the electrolytic cell are obtained in the case where the electrodes are blocking and the diffusion coefficients of the negative and positive ions are equal. The case where the diffusion coefficients are different is also considered. In this framework, our analysis indicates that in the considered frequency range the effective diffusion coefficient coincides with the ambipolar diffusion coefficient. A possible extension of our approach to the case where the electrodes are not blocking is discussed too.

  3. Energy, Electricity and Nuclear Power Estimates for the Period up to 2050. 2011 Edition

    International Nuclear Information System (INIS)

    2011-01-01

    Reference Data Series No. 1 (RDS-1) is an annual publication - currently in its thirty first edition - containing estimates of energy, electricity and nuclear power trends up to the year 2050. RDS-1 starts with a summary of the situation of nuclear power in IAEA Member States as of the end of 2010. The data on nuclear power presented in Tables 1 and 2 are based on actual statistical data collected by the IAEA's power Reactor Information System (pRIS). However, energy and electricity data for 2010 are estimated, as the latest information available from the united Nations Department of Economic and Social Affairs is for 2008 only. population data originate from the world population prospects (2010 revision), published by the population Division of the united Nations Department of Economic and Social Affairs. The 2010 values again are estimates. As in previous editions, projections of future energy and electricity demand and the role of nuclear power are presented as low and high estimates encompassing the inherent uncertainties involved in projecting trends. The RDS-1 estimates should be viewed as very general growth trends whose validity must be constantly subjected to critical review. Beginning with the 30th edition of this publication, however, the end-point of the estimates was extended up to the year 2050 (instead of 2030). Looking beyond 2030 has been prompted by the interest expressed by numerous Member States currently without nuclear power in adding nuclear energy to their future national energy supply mixes. Given the extensive lead times in planning and implementing nuclear power programmes, a fair share of these are likely to result in actual plant commissioning and grid connection after 2030. Many international, national and private organizations routinely engage in energy demand and supply projections, including nuclear power. These projections are based on a multitude of different assumptions and aggregating procedures, which make a straightforward

  4. Market surveillance panel monitoring report on the IMO-administered electricity markets for the period from September 2002 - January 2003

    International Nuclear Information System (INIS)

    2003-01-01

    In comparison to previous years, the demand for electricity in Ontario continued to increase. Depleted hydroelectric resources, coupled with planned generator outages reduced the supply in the fall of 2002. An unseasonably hot September and higher than expected demand occurred simultaneously with the planned outages, resulting in relatively high on-peak prices in comparison to neighbouring markets. The prices compared favorably with the prices in the neighbouring American markets for the remainder of the period. Plans to fix the commodity price of electricity for a wide segment of consumers were announced by the Ontario government. This document was divided into four chapters. In the first chapter, market outcomes September 1, 2002 to January 31, 2003 were examined. An assessment of market behaviour was presented in chapter 2, while in chapter 3, a status report on the market performance concerns raised in the October Market Surveillance Panel (MSP) report was provided. The conclusions were discussed in chapter 4. 27 tabs., 23 figs

  5. Magneto-Induced ac Electrical Permittivity of Metal-Dielectric Composites with a Two Characteristic Length Scales Periodic Microstructure

    International Nuclear Information System (INIS)

    Strelniker, Y.M.; Bergman, D.J.

    1998-01-01

    A new effect was recently predicted in conducting composites that have a periodic microstructure: an induced strongly anisotropic dc magneto-resistance. This phenomenon is already verified on high mobility n-GaAs films. Here we discuss the possibility of observing analogous behavior in the ac electric permittivity of a metal-dielectric composite with a periodic microstructure in the presence of a strong magnetic field. We developed new analytical and numerical methods to treat the low-frequency magneto-optical properties in composite media with both disordered and periodic conducting micro-structures. Those methods allow us to study composites with inclusions of arbitrary shape (and arbitrary volume fraction) at arbitrarily strong magnetic field. This is exploited in order to calculate an effective dielectric tensor for this system as a function of applied magnetic field and ac frequency. We show that in a non-dilute metal-dielectric composite medium the magneto-plasma resonance and the cyclotron resonance depend upon both the applied magnetic field as well as on the geometric shape of the inclusion. Near such a resonance, it is possible to achieve large values for the ratio of the off-diagonal-to-diagonal electric permittivity tensor components, ε xy /ε xx , (since ε xx →0, while ε xy ≠0), which is analogous to similar ratio of the resistivity tensor components, ρ xy /ρ xx , in the case of dc magneto-transport problem. Motivated by this observation and by results of previous studies of dc magneto-transport in composite conductors, we then performed a numerical study of the ac magneto-electric properties of a particular metal-dielectric composite film with a periodic columnar microstructure which has a two characteristic length scales. The unit cell of such composite is prepared as follows: We placed the conducting square (in cross section) rods (first characteristic length scale) along the perimeter of the unit cell in order to create a dielectric host

  6. Age-specific infectious period shapes dynamics of pneumonia in bighorn sheep.

    Science.gov (United States)

    Plowright, Raina K; Manlove, Kezia R; Besser, Thomas E; Páez, David J; Andrews, Kimberly R; Matthews, Patrick E; Waits, Lisette P; Hudson, Peter J; Cassirer, E Frances

    2017-10-01

    Superspreading, the phenomenon where a small proportion of individuals contribute disproportionately to new infections, has profound effects on disease dynamics. Superspreading can arise through variation in contacts, infectiousness or infectious periods. The latter has received little attention, yet it drives the dynamics of many diseases of critical public health, livestock health and conservation concern. Here, we present rare evidence of variation in infectious periods underlying a superspreading phenomenon in a free-ranging wildlife system. We detected persistent infections of Mycoplasma ovipneumoniae, the primary causative agent of pneumonia in bighorn sheep (Ovis canadensis), in a small number of older individuals that were homozygous at an immunologically relevant genetic locus. Interactions among age-structure, genetic composition and infectious periods may drive feedbacks in disease dynamics that determine the magnitude of population response to infection. Accordingly, variation in initial conditions may explain divergent population responses to infection that range from recovery to catastrophic decline and extirpation. © 2017 John Wiley & Sons Ltd/CNRS.

  7. Layered Electrical Product Application Protocol (AP). Draft: Initial Graphics Exchange Specification (IGES)

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    An application protocol is an information systems engineering view of a specific product. The view represents an agreement on the generic activities needed to design and fabricate the product, the agreement on the information needed to support those activities, and the specific constructs of a product data standard for use in transfering some or all of the information required. This applications protocol describes the data for electrical and electronic products in terms of a product description standard called the Initial Graphics Exchange Specification (IGES). More specifically, the Layered Electrical Product IGES Application Protocol (AP) specifies the mechanisms for defining and exchanging computer-models and their associated data for those products which have been designed in two dimensional geometry so as to be produced as a series of layers in IGES format. The AP defines the appropriateness of the data items for describing the geometry of the various parts of a product (shape and location), the connectivity, and the processing and material characteristics. Excluded is the behavioral requirements which the product was intended to satisfy, except as those requirements have been recorded as design rules or product testing requirements.

  8. Design, Specification, and Synthesis of Aircraft Electric Power Systems Control Logic

    Science.gov (United States)

    Xu, Huan

    Cyber-physical systems integrate computation, networking, and physical processes. Substantial research challenges exist in the design and verification of such large-scale, distributed sensing, actuation, and control systems. Rapidly improving technology and recent advances in control theory, networked systems, and computer science give us the opportunity to drastically improve our approach to integrated flow of information and cooperative behavior. Current systems rely on text-based specifications and manual design. Using new technology advances, we can create easier, more efficient, and cheaper ways of developing these control systems. This thesis will focus on design considerations for system topologies, ways to formally and automatically specify requirements, and methods to synthesize reactive control protocols, all within the context of an aircraft electric power system as a representative application area. This thesis consists of three complementary parts: synthesis, specification, and design. The first section focuses on the synthesis of central and distributed reactive controllers for an aircraft elec- tric power system. This approach incorporates methodologies from computer science and control. The resulting controllers are correct by construction with respect to system requirements, which are formulated using the specification language of linear temporal logic (LTL). The second section addresses how to formally specify requirements and introduces a domain-specific language for electric power systems. A software tool automatically converts high-level requirements into LTL and synthesizes a controller. The final sections focus on design space exploration. A design methodology is proposed that uses mixed-integer linear programming to obtain candidate topologies, which are then used to synthesize controllers. The discrete-time control logic is then verified in real-time by two methods: hardware and simulation. Finally, the problem of partial observability and

  9. Multi-period equilibrium/near-equilibrium in electricity markets based on locational marginal prices

    Science.gov (United States)

    Garcia Bertrand, Raquel

    In this dissertation we propose an equilibrium procedure that coordinates the point of view of every market agent resulting in an equilibrium that simultaneously maximizes the independent objective of every market agent and satisfies network constraints. Therefore, the activities of the generating companies, consumers and an independent system operator are modeled: (1) The generating companies seek to maximize profits by specifying hourly step functions of productions and minimum selling prices, and bounds on productions. (2) The goals of the consumers are to maximize their economic utilities by specifying hourly step functions of demands and maximum buying prices, and bounds on demands. (3) The independent system operator then clears the market taking into account consistency conditions as well as capacity and line losses so as to achieve maximum social welfare. Then, we approach this equilibrium problem using complementarity theory in order to have the capability of imposing constraints on dual variables, i.e., on prices, such as minimum profit conditions for the generating units or maximum cost conditions for the consumers. In this way, given the form of the individual optimization problems, the Karush-Kuhn-Tucker conditions for the generating companies, the consumers and the independent system operator are both necessary and sufficient. The simultaneous solution to all these conditions constitutes a mixed linear complementarity problem. We include minimum profit constraints imposed by the units in the market equilibrium model. These constraints are added as additional constraints to the equivalent quadratic programming problem of the mixed linear complementarity problem previously described. For the sake of clarity, the proposed equilibrium or near-equilibrium is first developed for the particular case considering only one time period. Afterwards, we consider an equilibrium or near-equilibrium applied to a multi-period framework. This model embodies binary

  10. Mortality in the cohort of nuclear workers of the French electricity company: 1968-2003 period

    International Nuclear Information System (INIS)

    Rogel, A.; Joly, K.; Metz-Flamant, C.; Laurier, D.; Tirmarche, M.; Hubert, D.; Garcier, Y.

    2008-01-01

    Full text: Background: We conducted a mortality study on a cohort of French nuclear workers employed at Electricite de France (EDF). A first mortality analysis relied on the period 1968-1994. Present results consider an updated mortality analysis including 9 additional years of follow-up and rely on the period 1968-2003. Methods: The cohort includes 22,393 workers, 96% of them are males. Employment data were updated using Personnel EDF file. Vital status was ascertained using the French National Registry of individual identification, and further completed using EDF personnel and pension files. Causes of death were obtained through the National file of causes of death. The observed mortality was compared with national rates by indirect standardisation and expressed by Standardised Mortality Ratios (SMR). All causes, all cancers and external causes SMRs were detailed according to sex, age and calendar year. Variations according to date of entry into cohort, duration of employment and socio-economic status (SES) were studied. Comparison with the earlier follow-up is presented. Results: At the present study end point (31/12/2003), 74% of workers are still in active service. Only 0.3% of workers are lost to follow up. The total number of person-years is nearly 450,000. Causes were ascertained for 96 % of deaths. The total number of deaths is 874: 307 are cancer deaths, including 16 leukaemia. SMRs for all causes of death and all cancers show a significant deficit compared to the French national mortality. Significant variations of all causes and all cancers SMRs according to SES were observed. No significant excess compared to French national mortality was observed for any of the 30 different cancer sites studied. Borderline significant excess were observed however for pancreatic, pleural, kidney and brain cancer. SMR for leukaemia is equal to unity. Conclusion: There is a clear evidence for an effect of selection of healthy individuals into the workforce. Although 9

  11. Standard technical specifications General Electric plants, BWR/6. Volume 1, Revision 1

    International Nuclear Information System (INIS)

    1995-04-01

    This report documents the results of the combined effort of the NRC and the industry to produce improved Standard Technical Specifications (STS), Revision 1 for General Electric BWR/6 Plants. The changes reflected in Revision 1 resulted from the experience gained from license amendment applications to convert to these improved STS or to adopt partial improvements to existing technical specifications. This NUREG is the result of extensive public technical meetings and discussions between the Nuclear Regulatory Commission (NRC) staff and various nuclear power plant licensees, Nuclear Steam Supply System (NSSS) Owners Groups, NSSS vendors, and the Nuclear Energy Institute (NEI). The improved STS were developed based on the criteria in the Final Commission Policy Statement on Technical Specifications Improvements for Nuclear Power Reactors, dated July 22, 1993. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the Specifications for all chapters and sections of the improved STS. Volume 2 contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1--3.3 of the improved STS. Volume 3 contains the Bases for Sections 3.4--3.10 of the improved STS

  12. Becoming a teacher educator: experiences with a specific induction period for beginning teacher educators.

    NARCIS (Netherlands)

    dr Rita Schildwacht; MEd Marly Gootzen; dr.ir. Quinta Kools; MEd Marije Veraa

    2012-01-01

    Introduction and theoretical background In the past few years, there has been a growing interest in the specific position of beginning teacher educators. In the book 'Becoming a teacher Educator' (Swennen & Van der Klink, 2009) several chapters deal with this subject. In conclusion, teacher

  13. Effect of maternal dry period length on colostrum immunoglobulin content and natural and specific antibody titers in calves

    NARCIS (Netherlands)

    Mayasari, N.; Vries Reilingh, de G.; Nieuwland, M.G.B.; Remmelink, G.J.; Parmentier, H.K.; Kemp, B.; Knegsel, van A.T.M.

    2015-01-01

    The objective was to study the effect of dry period length in dairy cows on immunoglobulin content and natural antibodies (NAb) titers in colostrum, growth, and plasma natural and specific antibody titers in plasma of calves. Holstein-Friesian dairy cows (n = 167) were randomly assigned to 3 dry

  14. Nuclear electronic equipment for control and monitoring boards. Specifications and test methods of direct current period meters

    International Nuclear Information System (INIS)

    Roquefort, Henri; Chapelot; Ramard; Tardif; Tournier; Vaux

    1973-11-01

    After a few words of introduction, mention of the main notations used and the definition of certain terms, the field of application of the document is outlined and a list of references given. The main specifications of electronic 'direct current period meter' subassemblies for the monitoring, control and safety of nuclear reactors are then defined and the corresponding test methods described. The apparatus measures on a logarithmic scale the neutron fluence rate of a reactor by means of an ionisation chamber and supplies 'period' data relative to the fluence rate variation in time. The specifications and test methods are given for the different components: logarithmic amplifier, time derivative unit, threshold releases, high tension supply for ionisation chamber, auxiliary circuits and finally the complete period meter. (author) [fr

  15. Applying Nitrogen Site-Specifically Using Soil Electrical Conductivity Maps and Precision Agriculture Technology

    Directory of Open Access Journals (Sweden)

    E.D. Lund

    2001-01-01

    Full Text Available Soil texture varies significantly within many agricultural fields. The physical properties of soil, such as soil texture, have a direct effect on water holding capacity, cation exchange capacity, crop yield, production capability, and nitrogen (N loss variations within a field. In short, mobile nutrients are used, lost, and stored differently as soil textures vary. A uniform application of N to varying soils results in a wide range of N availability to the crop. N applied in excess of crop usage results in a waste of the grower’s input expense, a potential negative effect on the environment, and in some crops a reduction of crop quality, yield, and harvestability. Inadequate N levels represent a lost opportunity for crop yield and profit. The global positioning system (GPS-referenced mapping of bulk soil electrical conductivity (EC has been shown to serve as an effective proxy for soil texture and other soil properties. Soils with a high clay content conduct more electricity than coarser textured soils, which results in higher EC values. This paper will describe the EC mapping process and provide case studies of site-specific N applications based on EC maps. Results of these case studies suggest that N can be managed site-specifically using a variety of management practices, including soil sampling, variable yield goals, and cropping history.

  16. The Specific Features of an Early Period after Minimally Invasive Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    V. A. Shmyrev

    2014-01-01

    Full Text Available Objective: to comparatively evaluate the perioperative clinical period in patients operated on via miniinvasive access and median sternotomy.Subjects and methods. A retrospective analysis included all patients who had undergone correction of mitral valve defect with or without tricuspid valve correction and atrial ablation. 121 and 112 patients were operated on through miniinvasive access (a study group and median sternothomy (a control group, respectively.Results. The duration (median [25; 75 percentiles] of aortic occlusion in the study group (89 [71; 120] min was significantly longer than that in the control group (65 [52; 84] min; р<0.01. Acute heart failure complicated the clinical course in 28 (23.1% and 15 (13.4% cases in the study and control groups, respectively; р=0.06. In the miniinvasiveaccess group, two deaths were caused by intraoperative aortic dissection. There was no significant difference in the length of stay in the intensive care unit and in that of hospitalization between the groups.Conclusion. The findings are generally correlated with the world data obtained while implementing the procedure. The frequency and pattern of complications due to miniinvasive correction of mitral valve defect require additional financial expenditures and human resources. It is necessary to analyze the longterm results of treatment for the reasonable evaluation of the efficiency and expediency of using this procedure.

  17. Data-based method for creating electricity use load profiles using large amount of customer-specific hourly measured electricity use data

    International Nuclear Information System (INIS)

    Raesaenen, Teemu; Voukantsis, Dimitrios; Niska, Harri; Karatzas, Kostas; Kolehmainen, Mikko

    2010-01-01

    The recent technological developments monitoring the electricity use of small customers provides with a whole new view to develop electricity distribution systems, customer-specific services and to increase energy efficiency. The analysis of customer load profile and load estimation is an important and popular area of electricity distribution technology and management. In this paper, we present an efficient methodology, based on self-organizing maps (SOM) and clustering methods (K-means and hierarchical clustering), capable of handling large amounts of time-series data in the context of electricity load management research. The proposed methodology was applied on a dataset consisting of hourly measured electricity use data, for 3989 small customers located in Northern-Savo, Finland. Information for the hourly electricity use, for a large numbers of small customers, has been made available only recently. Therefore, this paper presents the first results of making use of these data. The individual customers were classified into user groups based on their electricity use profile. On this basis, new, data-based load curves were calculated for each of these user groups. The new user groups as well as the new-estimated load curves were compared with the existing ones, which were calculated by the electricity company, on the basis of a customer classification scheme and their annual demand for electricity. The index of agreement statistics were used to quantify the agreement between the estimated and observed electricity use. The results indicate that there is a clear improvement when using data-based estimations, while the new-estimated load curves can be utilized directly by existing electricity power systems for more accurate load estimates.

  18. Data-based method for creating electricity use load profiles using large amount of customer-specific hourly measured electricity use data

    Energy Technology Data Exchange (ETDEWEB)

    Raesaenen, Teemu; Niska, Harri; Kolehmainen, Mikko [Department of Environmental Sciences, University of Eastern Finland P.O. Box 1627, FIN-70211 Kuopio (Finland); Voukantsis, Dimitrios; Karatzas, Kostas [Department of Mechanical Engineering, Aristotle University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2010-11-15

    The recent technological developments monitoring the electricity use of small customers provides with a whole new view to develop electricity distribution systems, customer-specific services and to increase energy efficiency. The analysis of customer load profile and load estimation is an important and popular area of electricity distribution technology and management. In this paper, we present an efficient methodology, based on self-organizing maps (SOM) and clustering methods (K-means and hierarchical clustering), capable of handling large amounts of time-series data in the context of electricity load management research. The proposed methodology was applied on a dataset consisting of hourly measured electricity use data, for 3989 small customers located in Northern-Savo, Finland. Information for the hourly electricity use, for a large numbers of small customers, has been made available only recently. Therefore, this paper presents the first results of making use of these data. The individual customers were classified into user groups based on their electricity use profile. On this basis, new, data-based load curves were calculated for each of these user groups. The new user groups as well as the new-estimated load curves were compared with the existing ones, which were calculated by the electricity company, on the basis of a customer classification scheme and their annual demand for electricity. The index of agreement statistics were used to quantify the agreement between the estimated and observed electricity use. The results indicate that there is a clear improvement when using data-based estimations, while the new-estimated load curves can be utilized directly by existing electricity power systems for more accurate load estimates. (author)

  19. Acute lethality data for Ontario's electric power generation sector effluents covering the period from December 1990 to May 1991

    International Nuclear Information System (INIS)

    Poirier, D.G.; Lee, J.T.; Mueller, M.C.; Westlake, G.F.

    1995-01-01

    Regulations require that electric power generation facilities monitor their liquid effluents. Acute lethality tests are simple, rapid standard methods for measuring potential impacts on aquatic ecosystems. These toxicity tests will detect harmful concentrations of chemicals and mixtures of compounds in effluents, but compliance with end of pipe limits for acute toxicity will not necessarily control all adverse environmental effects. In these tests, aquatic organisms were exposed to undiluted effluent, as well as a series of effluent dilutions for a fixed period of time. This report is a compilation of six months of test results. Typically the most toxic samples were taken from the waste treatment plant (WTP) neutral sumps. This was true for fossil fueled as well as for nuclear generating stations. tabs., figs

  20. Age-specific reference values for serum FSH and estradiol levels throughout the reproductive period.

    Science.gov (United States)

    Grisendi, Valentina; Spada, Elena; Argento, Cindy; Plebani, Maddalena; Milani, Silvano; Seracchioli, Renato; Volpe, Annibale; La Marca, Antonio

    2014-06-01

    High serum day 3 FSH levels are associated with poor ovarian reserve and reduced fertility, but the interpretation of FSH values according to age is still not univocal. The purpose of this study was to determine age-dependent reference values in women with regular menstrual cycles and FSH as a guide for specialists. The study was performed at the Department of Mother-Infant of a University-based tertiary care centre. One-hundred ninety-two healthy normal menstruating women were recruited for the study. All patients attended the department on menstrual cycle day 3 for a blood sample for FSH and estradiol determination. A linear relationship between FSH or estradiol serum levels and age was observed. The FSH level increased by 0.11 IU for every year of age (1 IU for every 9 years of age). The values of FSH and estradiol corresponding to the 5th, 25th, 50th, 75th, 95th centiles for any specific age have been calculated. Serum FSH levels need to be interpreted according to age-dependent reference values. Serum FSH levels on 95th centile for any age may represent a warning sign for reduced ovarian reserve.

  1. Impact of Spanish electricity mix, over the period 2008–2030, on the Life Cycle energy consumption and GHG emissions of Electric, Hybrid Diesel-Electric, Fuel Cell Hybrid and Diesel Bus of the Madrid Transportation System

    International Nuclear Information System (INIS)

    García Sánchez, Juan Antonio; López Martínez, José María; Lumbreras Martín, Julio; Flores Holgado, María Nuria; Aguilar Morales, Hansel

    2013-01-01

    Highlights: • We assess the performance of 4 buses that run on different alternative fuel types and technologies. • The buses assessed are Fuel Cell-Hybrid Bus, Hybrid Diesel-Electric Bus, Battery Electric Bus, and a Diesel Bus. • We examine the environmental impact caused by the Life Cycle of each vehicle technology, fossil fuel and energy carrier. • Life Cycle of Battery Electric Bus shows that it has a big potential of improvement in terms of environmental impact. - Abstract: In spite of the advanced research in automotive technology, and the improvement of fuels, the road transport sector continues to be an environmental concern, since the increase in transport demand is offsetting the effects of these technological improvements. Therefore, this poses the following question: what combination of technology and fuel is more efficient in terms of energy consumption and green house gas (GHG) emissions? To fully address this question it is necessary to carry out a Life Cycle Assessment (LCA). This paper presents a global LCA of 4 buses that run on the following fuel types and technologies: (1) Fuel Cell- Hybrid Bus, (2) Hybrid Diesel-Electric Bus (series configuration), (3) Battery Electric Bus and (4) Combustion Ignition Engine Bus. The impact categories assessed are: primary energy consumption, fossil energy and GHG emissions. Among the principal results, we can conclude that the Global LCA of buses (3) and (1) (which are the more sensitive pathways to the electricity mix variation) have for the 2008–2030 period a room for improvement of 25.62% and 28.16% in terms of efficiency of fossil energy consumption and a potential GHG emission reduction of 28.70% and 30.88% respectively

  2. Changes and specificities in health behaviors among healthcare students over an 8-year period

    Science.gov (United States)

    Delay, J.; Grigioni, S.; Déchelotte, P.; Ladner, J.

    2018-01-01

    Background Healthcare students are future health care providers and serve as role models and coaches to enhance behaviors for healthy lifestyles. However healthcare students face multiple stressors that could lead to adopting risk behaviors. Objectives To assess the changes in health risk factors among healthcare students between 2007 and 2015, and to identify specific health behaviors based on the curriculum in a population of healthcare students: Methods Two cross sectionnal studies were conducted in 2007 and 2015 among nursing, medical, pharmacy, and physiotherapy students (Rouen, France). During compulsory courses and examination sessions students filled self-administered questionnaires on socio-demographic characteristics and behavior as: tobacco smoking, alcohol consumption, cannabis consumption, eating disorders, regular practice of sport, perceived health, stress and use of psychotropic drugs. Results 2,605 healthcare students were included (1,326 in 2007 and 1,279 in 2015), comprising 1,225 medical students (47.0%), 738 nursing students (28.3%), 362 pharmacy students (13.9%), and 280 physiotherapy students (10.8%). Between 2007 and 2015, occasional binge drinking and regular practice of sport increased significantly among healthcare students, respectively AOR = 1.48 CI95% (1.20–1.83) and AOR = 1.33 CI95% (1.11–1.60), regular cannabis consumption decreased significantly, AOR = 0.32 CI95% (0.19–0.54). There was no change in smoking or overweight/obese. There was a higher risk of frequent binge drinking and a lower risk of tobacco smoking in all curricula than in nursing students. Medical students practiced sport on a more regular basis, were less overweight/obese, had fewer eating disorders than nursing students. Conclusion Our findings demonstrate a stable frequency of classic behaviors as smoking but a worsening of emerging behaviors as binge drinking among healthcare students between 2007 and 2015. Health behaviors differed according to healthcare

  3. The integration of the periodic production in the liberalized electric power markets: from the technic expenditures to the economic taxes imposed by the operating rules of the markets

    International Nuclear Information System (INIS)

    Menanteau, Ph.; Finon, D.; Lamy, M.L.

    2003-03-01

    In the framework of the climatic change and the energy supply safety, the european directive aims to promote the renewable energy production in Europe. Some of the renewable energy sources, as the wind power or the micro-hydroelectric power, are naturally periodic. Their introduction in the electric networks will create problems because of this periodic nature, problems which are new for the electric network producers and managers. These problems generate technical expenditures, which may be compensate by the economic penalties of the electric power market operating. In this context the document details the expenditures associated to the periodicity, the economic penalties by an analysis of the british market and analyses the possibilities to limit these economic penalties in order to reduce the conflicts between the electric market liberalization and the promotion of the renewable energies development. (A.L.B.)

  4. Electricity mix and ecological assessments. Consequences of the choice of specific electricity mixes in analyses of the environmental performance of products and services

    International Nuclear Information System (INIS)

    Menard, M.; Dones, R.; Gantner, U.

    1998-12-01

    The study aims at analysing the methodological issues associated with the definition of electricity mixes and discussing the consequences of the choice of specific electricity mixes in analyses of the environmental performance of products and services, based on Life Cycle Assessment (LCA). This report has been designed as a guideline to support LCA practitioners in the systematic identification of the most appropriate electricity mixes for LCA applications. A detailed checklist has been developed for this purpose. It includes the following items: type of electricity supply (from the net, self production, direct contracts); voltage level; country/place of utilisation; year of utilisation; season/daytime of utilisation; import/export model; and, marginal vs. average approach. A few examples, utilising published LCA studies, illustrate the impacts of the insights gained in the present work. Although primarily aimed at applications in Switzerland, the main concepts, the modelling and parts of the information provided can also be applied to other European countries. In addition to the three models proposed earlier for the assessment of the Swiss yearly average electricity mix, a new model (M4) has been developed in the frame of the present task in order to take into account the conditions characteristic for Switzerland as a transit land for electricity trades between its neighbour countries. All existing electricity mix models as well as selected environmental inventories are described and compared in the report. As an example of results, the CO 2 emissions calculated for the Swiss yearly electricity supply mix are relatively small (48 g/kWh with model M4, as compared with 497 g/kWh for the average UCPTE mix). Key information on the structure of electricity generation and trade in Europe is provided. The modelling of the electricity supply for most of the European countries is less sensitive to the choice of an electricity model than for Switzerland. Considering that

  5. Nuclear Electric Propulsion mission engineering study covering the period April 1971 to January 1973. Volume I. Executive summary. Final report

    International Nuclear Information System (INIS)

    1973-03-01

    The results of a mission engineering analysis of nuclear-thermionic electric propulsion spacecraft for unmanned interplanetary and geocentric missions are presented. Critical technologies assessed are associated with the development of Nuclear Electric Propulsion (NEP), and the impact of its availability on future space programs. Specific areas of investigation include outer planet and comet rendezvous mission analysis, NEP Stage design for geocentric and interplanetary missions, NEP system development cost and unit costs, and technology requirements for NEP Stage development. A multimission NEP Stage can be developed to perform both multiple geocentric and interplanetary missions. Development program costs for a 1983 launch would be of the order of $275 M, including hardware and reactor development, flight system hardware, and mission support. Recurring unit costs for flight NEP systems would be of the order of $25 M for a 120 kWe NEP Stage. Identified pacing NEP technology requirements are the development of 20,000 full power hour ion thrusters and thermionic reactor, and the development of related power conditioning. The resulting NEP Stage design provides both inherent reliability and high payload mass capability. High payload mass capability can be translated into both low payload cost and high payload reliability. NEP Stage and payload integration is compatible with the Space Shuttle

  6. Nuclear Electric Propulsion mission engineering study covering the period April 1971 to January 1973. Volume II. Final report

    International Nuclear Information System (INIS)

    1973-03-01

    The results of a mission engineering analysis of nuclear-thermionic electric propulsion spacecraft for unmanned interplanetary and geocentric missions are summarized. Critical technologies assessed are associated with the development of Nuclear Electric Propulsion (NEP), and the impact of its availability on future space programs. Specific areas of investigation include outer planet and comet rendezvous mission analysis, NEP Stage design for geocentric and interplanetary missions NEP system development cost and unit costs, and technology requirements for NEP Stage development. A multi-mission NEP Stage can be developed to perform both multiple geocentric and interplanetary missions. Development program costs for a 1983 launch would be of the order of $275 M, including hardware and reactor development, flight system hardware, and mission support. Recurring unit costs for flight NEP systems would be of the order of $25 M for a 120kWe NEP Stage. Identified pacing NEP technology requirements are the development of 20,000 full power hour ion thrusters and thermionic reactor, and the development of related power conditioning. The resulting NEP Stage design provides both inherent reliability and high payload mass capability. High payload mass capability can be translated into both low payload cost and high payload reliability. NEP Stage and payload integration is compatible with the Space Shuttle

  7. Development of specific materials for the high power electronic components in electric vehicles

    Directory of Open Access Journals (Sweden)

    Kaabi Abderrahmen

    2013-11-01

    Full Text Available The powerchain in electric vehicles sets new demands on semi conductors and their packaging. The latter will be specifically addressed. The power density per cm2 in DC/DC or DC/AC converters requires a mastering of thermomecahnical aspects. The temperature cyling, the environment under the hood of the vehicles and the “hybrid” technology impose severe constraints on the assemblies which may be met by architectured substrates, new options for assemblies and efficient cooling systems. An optimised semi conductor substrate associating copper and invar in a will be developed, relying on roll bonding to produce the 3D architecture. Roll bonding may also be used to associate aluminium and iron to produce light laminates with a CEM performance.

  8. Electrically rechargeable zinc/air battery: a high specific energy system

    Energy Technology Data Exchange (ETDEWEB)

    Holzer, F; Sauter, J -C; Masanz, G; Mueller, S [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    This contribution describes our research and development efforts towards the demonstration of a light-weight, low-cost 12 V/20 Ah electrically rechargeable Zn/air battery. We successfully developed electrodes having active areas of up to 200 cm{sup 2}. Deep discharge cycles at different currents as well as current-voltage curves are reported for a 10 cell Zn/air battery (serial connection) with a rated capacity of 20 Ah. Based on the discharge cycle at a power of 19 W, and the weight of the battery, a specific energy of more than 90 Wh/kg could be evaluated for the whole system. (author) 4 figs., 1 tab., 5 refs.

  9. Region-specific study of the electric utility industry: financial history and future power requirements for the VACAR region

    International Nuclear Information System (INIS)

    Pochan, M.J.

    1985-07-01

    Financial data for the period 1966 to 1981 are presented for the four investor-owned electric utilities in the VACAR (Virginia-Carolinas) region. This region was selected as representative for the purpose of assessing the availability, reliability, and cost of electric power for the future in the United States. The estimated demand for power and planned additions to generating capacity for the region through the year 2000 are also given

  10. Electricity

    CERN Document Server

    Basford, Leslie

    2013-01-01

    Electricity Made Simple covers the fundamental principles underlying every aspect of electricity. The book discusses current; resistance including its measurement, Kirchhoff's laws, and resistors; electroheat, electromagnetics and electrochemistry; and the motor and generator effects of electromagnetic forces. The text also describes alternating current, circuits and inductors, alternating current circuits, and a.c. generators and motors. Other methods of generating electromagnetic forces are also considered. The book is useful for electrical engineering students.

  11. Characterization of the household electricity consumption in the EU, potential energy savings and specific policy recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Paula; Almeida, Anibal de (ISR-Univ. of Coimbra, Dep. Electrical Engineering (Portugal)). e-mail: pfonseca@isr.uc.pt; Feilberg, Nicolai (SINTEF Energiforskning AS (Norway)); Markogiannakis, George (Centre for Renewable Energy Sources - CRES (Greece)); Kofod, Casper (Energy piano (Denmark))

    2009-07-01

    Although significant improvements in energy efficiency have been achieved in home appliances and lighting, the electricity consumption in the average EU-27 household has been increasing by about 2% per year during the past 10 years. Some reasons for such increase are associated with an increased degree of basic comfort and level of amenities (particularly in the new EU member countries) and also with the widespread utilization of relatively new types of loads whose penetration and use has experienced a very significant growth in recent years. With the objective of contributing to an increased understanding of the energy consumption in the EU-27 households for the different types of equipment including the consumers' behaviour and comfort levels, and to identify demand trends, a large energy monitoring campaign, co-funded by the IEE programme, was carried out in 12 countries, accompanied by a lifestyle consumer survey. From the measurements carried out it can be concluded that IT and entertainment loads, including standby, are a key contributor to the power demand. In basically all types of loads there is wide range of performance levels, including new emerging technologies, in the models available in the market. Available technology, associated with responsible consumer behaviour, can reduce wasteful consumption. The potential electricity savings that exist in the residential sector in Europe, and that can already be implemented by existing means, like the use of BAT (best available technology) efficient appliances or the elimination/mitigation of standby consumption, can reach up to 48% savings. Specific policy recommendations to promote market transformation and behavioural changes in the equipment selection and operation have been identified.

  12. Effect of iron ions and electric field on nitrification process in the periodic reversal bio-electrocoagulation system.

    Science.gov (United States)

    Qian, Guangsheng; Hu, Xiaomin; Li, Liang; Ye, Linlin; Lv, Weijian

    2017-11-01

    This study explored the nitrification mechanism of a periodic reversal bio-electrocoagulation system with Fe-C electrodes. The ammonia nitrogen removal was compared in four identical cylindrical sequencing bath reactors. Two of them were reactors with Fe-C electrodes (S1) and C-C electrodes (S2), respectively. The other two were a reactor with iron ions (S3) and a traditional SBR (S4), respectively. The results demonstrated that the effect on enhancing nitrification in S1 was the best among all four SBRs, followed by S3, S2 and S4. Iron ions increased the biomass, and electric field improved the proton transfer and enzyme activity. The dominant bacterial genera in the four SBRs were Hyphomicrobium, Thauera, Nitrobacter, Nitrosomonas, Paracoccus and Hydrogenophaga. The iron ions may increase the levels of Nitrosomonas and Nitrobacter, both of which were the main microbes of the nitrification process. This study provided a significant and meaningful understanding of nitrification in a bio-electrocoagulation system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Specificity of the tomography implementation in electric arc domain - Validity in medical imaging

    International Nuclear Information System (INIS)

    Benech, Julie

    2008-01-01

    The aim of these works was to implement a new experimental method to characterize 3D thermal plasmas by emission spectroscopy. The method used is based on tomographic technique which is widely used in medical imaging nowadays. However, tomography that we have developed and applied to electric arc is specific as the number of accessible projections angles is strongly limited: 4 projections our case against basically 64 in medical imaging. The particularity of our experimental tomographic system is that measurements are resolved both spectrally and spatially. The spectral resolution is necessary to determine the temperature values from method based on atomic line intensity. The spatial resolution is needed to simultaneously acquire the whole width of the plasma and so to reconstruct a whole cross-section in only one acquisition. One of the principal objective was to realize the experimental system of four-view tomography for thermal plasmas. Thanks to this device, we showed that the characterization of non-axisymmetric plasma is possible and that it enables to reconstruct 3D temperature maps. Finally, our tomographic method is applied with medical imaging data acquired in SPECT (Single Photon Emission Computed Tomography). These tests allowed validating the use of our tomographic reconstruction technique in SPECT, particularly the used iterative algebraic algorithm and the limited-view configuration. (author) [fr

  14. Certain laws governing the influence of high molecular polymer additives on specific electrical conductivity and viscosity of zincate alkaline solution

    Energy Technology Data Exchange (ETDEWEB)

    Dmitrenko, V.Ye.; Toropetsera, T.N.; Zubov, M.S.

    1983-01-01

    A study was made of the influence of polymer additives of different nature: polyelectrolyte, copolymer of ethylene with maleic anhydride, polymethacrylic acid and nonpolyectrolyte copolymer of vinyl alcohol with vinyleneglycol and polyvinyleneglycol on specific electrical conductance and viscosity of the zincate alkaline solution. It is indicated that with an increase in the content of additives, the specific conductance of the solution diminishes according to a linear law, while the viscosity rises. The additives of polyelectrolyte nature reduce more strongly the specific conductance and increase the viscosity than the nonpolyelectrolyte additives. From a comparison of the data on specific conductance and viscosity the following conclusion is drawn: the more the polymer ''structures'' the zincate alkaline solution, the more strongly it reduces its specific electrical conductance.

  15. SPECIFIC FEATURES OF POWER CONSUMPTION OF LED DEVICES AND ACCOUNTING THEM IN CALCULATION OF ELECTRICAL NETWORKS

    Directory of Open Access Journals (Sweden)

    V. N. Radkevich

    2016-01-01

    Full Text Available The indicators of power consumption of lighting devices based on LEDs are studied depending on the supplied voltage. For the lamp and floodlight with LEDs active and reactive power, current and power factor as a function of voltage (which value changed in the range 200–245 V were experimentally determined. The analysis of experimental data demonstrated that due to the drivers in the specified voltage range the active power consumed by light devices remains practically unchanged. The reactive power of LED devices depends on the supplied voltage and is capacitive in its nature. In contrast with gas-discharge light sources the LED devices under study do not consume reactive power, but generate it. With the change of the supplied voltage from 200 to 245 V the value of the generated reactive power increases to 60 % for the floodlight and 50 % for the lamp. The LED floodlight has a low coefficient of active power. The current consumed by the floodlight has increased by 22 %, and by the lamp – by 13 %. The formulas for determining the maximum value of the length of the calculated section of single-phase group lines were developed, taking into account specific source data. LED light sources tend to feed by electric power by single-phase group lines. The number of lamps connected to single-phase lines is regulated by normative documents. Bearing this in mind as well as the small power of LED sources single-phase group lines are usually performed with conductors of the smallest possible cross section. The limit values of the length of the calculated section that correspond to a predetermined loss of voltage in line with ambient temperature from 15 to 60 °С were determined for them. The calculations demonstrated that for group lines that feed the LEDs, the choice of conductor cross-sections in accordance with permissible voltage loss is not critical. The determinant factor for the choice of the cross-section of the conductors of group electrical

  16. Outlook for Global Nuclear Power: Energy, Electricity and Nuclear Power Estimates for the Period up to 2050

    International Nuclear Information System (INIS)

    Gritsevskyi, A.

    2016-01-01

    Nuclear power's global expansion is projected to continue in the coming decades - albeit at a slowing pace - amid challenges including low fossil fuel prices, a sluggish world economy and the legacy of Japan's Fukushima Daiichi accident. Each year, the IAEA publishes projections of the world's nuclear power generating capacity in Energy, Electricity and Nuclear Power Estimates for the Period up to 2050, now in its 35th edition.The latest projections point to slower growth in nuclear power, in keeping with the trend since the 2011 Fukushima Daiichi accident. The world's nuclear power generating capacity is projected to expand by 2.4 percent by 2030, according to the low projections, compared with 7.7 percent estimated in 2014. In the high case, generating capacity is estimated to grow by 68 percent by 2030, versus 88 percent forecast last year. Uncertainty related to energy policy, license renewals, shutdowns and future constructions accounts for the wide range.The estimates also factor in the likely future retirement of many of the world's 438 nuclear reactors currently in operation, more than half of which are over 30 years old. Despite the need to replace scores of retiring reactors, nuclear power is still set to maintain - and possibly increase - its role in the world's low-carbon energy mix. It's important to understand that these projections, while carefully derived, are not predictions.The estimates should be viewed as very general growth trends, whose validity must be constantly subjected to critical review.(author).

  17. INVESTIGATION OF HEAT CONDUCTION AND SPECIFIC ELECTRIC IMPEDANCE OF POROUS MATERIALS

    Directory of Open Access Journals (Sweden)

    E. S. Golubtsova

    2004-01-01

    Full Text Available In this article there was investigated the influence of porosity and temperature change on heat condition and electrical resistance of porous iron (PZh4M nickel and steel 14X17H2. There are received the adequate equations of regression, establishing connection between heat conduction and electrical resistance of the investigated materials with their porosity and temperature.

  18. The role of specific features of the electronic structure in electrical resistivity of band ferromagnets Co2Fe Z ( Z = Al, Si, Ga, Ge, In, Sn, Sb)

    Science.gov (United States)

    Kourov, N. I.; Marchenkov, V. V.; Perevozchikova, Yu. A.; Weber, H. W.

    2017-05-01

    The electrical resistivity ρ( T) of the band ferromagnets Co2FeZ (where Z = Al, Si, Ga, Ge, In, Sn, and Sb are s- and p-elements of Mendeleev's Periodic Table) has been investigated in the temperature range 4.2 K < T < 1100 K. It has been shown that the dependences ρ( T) of these alloys in a magnetically ordered state at temperatures T < T C are predominantly determined by the specific features of the electronic spectrum in the vicinity of the Fermi level. The processes of charge carrier scattering affect the behavior of the electrical resistivity ρ( T) only in the vicinity of the Curie temperature T C and above, as well as in the low-temperature range (at T ≪ T C).

  19. VDE-specification for electrical equipment and apparatus in atmospheres endangered by explosive material. Draft. VDE-Bestimmung fuer elektrische Anlagen und deren Betriebsmittel in explosivgefaehrdeten Bereichen. Entwurf

    Energy Technology Data Exchange (ETDEWEB)

    1976-02-01

    These specifications are valid for the setting-up, changing, putting into operation and developing of electrical equipment, as well as for the application of electrical apparatus in such systems and in regions endangered by explosive materials.

  20. Region-specific study of the electric utility industry. Phase I, final report

    International Nuclear Information System (INIS)

    Wacaster, A.J.

    1985-07-01

    This report describes the financial background of the electric utility industry in VACAR, reports on the present condition of the industry and then assesses the future of this industry. The Virginia-Carolinas subregion (VACAR) of the Southeastern Electric Reliability Council (SERC) was selected for this regional study because of its cooperativeness and its representative mix of powerplants, for example coal, hydro, nuclear, oil. It was found that the supply of future economic electricity is in jeopardy because of the regulatory process, the increasing risk associated with large scale generating stations and the weakening of the nuclear option. A number of options for the future were considered, including deregulation, government ownership and retaining the present system with modifications. The option selected to improve the present condition of the electricity industry was to make the present system work. The present system is sound, and with modifications, problems could be solved within the existing framework. 8 figs., 4 tabs

  1. Large-Scale Battery System Development and User-Specific Driving Behavior Analysis for Emerging Electric-Drive Vehicles

    Directory of Open Access Journals (Sweden)

    Yihe Sun

    2011-04-01

    Full Text Available Emerging green-energy transportation, such as hybrid electric vehicles (HEVs and plug-in HEVs (PHEVs, has a great potential for reduction of fuel consumption and greenhouse emissions. The lithium-ion battery system used in these vehicles, however, is bulky, expensive and unreliable, and has been the primary roadblock for transportation electrification. Meanwhile, few studies have considered user-specific driving behavior and its significant impact on (PHEV fuel efficiency, battery system lifetime, and the environment. This paper presents a detailed investigation of battery system modeling and real-world user-specific driving behavior analysis for emerging electric-drive vehicles. The proposed model is fast to compute and accurate for analyzing battery system run-time and long-term cycle life with a focus on temperature dependent battery system capacity fading and variation. The proposed solution is validated against physical measurement using real-world user driving studies, and has been adopted to facilitate battery system design and optimization. Using the collected real-world hybrid vehicle and run-time driving data, we have also conducted detailed analytical studies of users’ specific driving patterns and their impacts on hybrid vehicle electric energy and fuel efficiency. This work provides a solid foundation for future energy control with emerging electric-drive applications.

  2. High voltage-derived enhancement of electric conduction in nanogap devices for detection of prostate-specific antigen

    Science.gov (United States)

    Park, Hyung Ju; Chi, Young Shik; Choi, Insung S.; Yun, Wan Soo

    2010-07-01

    We report a simple method of enhancing electric conductance in nanogap devices without any additional treatments, such as silver-enhancing process. The low electric conductance after selective immobilization of biofunctionalized gold nanoparticles in the gap region was greatly enhanced by repeated I-V scans at relatively high voltage ranges of -5 to 5 V, which was attributed to the formation of a new conduction pathway across the gap. The higher conduction state of the nanogap device showed a very stable I-V curve, which was used as an excellent measure of the existence of prostate-specific antigen.

  3. Specific heat and electric conductivity of zirconium alloy with 2,5 mass% niobium in the range of phase transitions

    International Nuclear Information System (INIS)

    Roshchupkin, V.V.; Pokrasin, M.A.; Chernov, A.I.; Semashko, N.A.

    1996-01-01

    Experimental investigation of specific heat and electric resistance of zirconium alloy with 2.5 mass% niobium in the range of phase transitions was conducted, using adiabatic calorimeter of original design, characterized by high sensitivity, efficiency and high accuracy. It was revealed that temperature dependence of specific heat was characterized by anomalous growth at 590 deg C, related with (α+β Nb )→(α+β Zr )-transition, and at 810 deg -related with (α+β Zr )→β Zr - transition. Temperature dependence of electric resistance was specific in the region of α+β Zr →β Zr phase transition. It was established that revealed anomalies were connected with high oxygen absorption at high temperatures. 11 refs., 1 fig., 1 tab

  4. Electricity

    International Nuclear Information System (INIS)

    Tombs, F.

    1983-01-01

    The subject is discussed, with particular reference to the electricity industry in the United Kingdom, under the headings; importance and scope of the industry's work; future fuel supplies (estimated indigenous fossil fuels reserves); outlook for UK energy supplies; problems of future generating capacity and fuel mix (energy policy; construction programme; economics and pricing; contribution of nuclear power - thermal and fast reactors; problems of conversion of oil-burning to coal-burning plant). (U.K.)

  5. Site-specific Pt deposition and etching on electrically and thermally isolated SiO2 micro-disk surfaces

    International Nuclear Information System (INIS)

    Saraf, Laxmikant V

    2010-01-01

    Electrically and thermally isolated surfaces are crucial for improving the detection sensitivity of microelectronic sensors. The site-specific in situ growth of Pt nano-rods on thermally and electrically isolated SiO 2 micro-disks using wet chemical etching and a focused ion/electron dual beam (FIB-SEM) is demonstrated. Fabrication of an array of micro-cavities on top of a micro-disk is also demonstrated. The FIB source is utilized to fabricate through-holes in the micro-disks. Due to the amorphous nature of SiO 2 micro-disks, the Ga implantation possibly modifies through-hole sidewall surface chemistry rather than affecting its transport properties. Some sensor design concepts based on micro-fabrication of SiO 2 micro-disks utilizing thermally and electrically isolated surfaces are discussed from the viewpoint of applications in photonics and bio-sensing.

  6. Hybrid component specification optimization for a medium-duty hybrid electric truck

    NARCIS (Netherlands)

    Hofman, T.; Steinbuch, M.; Druten, van R.M.; Serrarens, A.F.A.

    2008-01-01

    This paper presents a modelling and simulation approach for determining the optimal degree-of-hybridisation for the drive train (engine, electric machine size) and the energy storage system (battery, ultra capacitor) for a medium-duty truck. The results show that the degree-of-hybridisation of known

  7. Computer modeling and laboratory experiments of a specific borehole to surface electrical monitoring technique (BSEMT)

    NARCIS (Netherlands)

    Meekes, J.A.C.; Zhang, X.; Abdul Fattah, R.

    2011-01-01

    Geophysical monitoring of the dynamical behavior of subsurface reservoirs (oil, gas, CO2) remains an important issue in geophysical research. A new idea for reservoir monitoring based on electrical resistivity tomography was developed at TNO. The essential element of the so-called BSEMT (Borehole to

  8. Segmentation of electric energy customers by specific niches; Segmentacao de clientes de energia eletrica por nichos especiais

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Ana Lucia Rodrigues da; Jannuzzi, Gilberto de Martino [Universidade Estadual de Campinas (UNICAMP), SP (Brazil)], E-mail: jannuzzi@fen.unicamp.br

    2009-04-15

    The article presents the classic segmentation used in electric energy industry for large customers. The paper argues the limitations of this classification, as well as, the potentialities to classify customers for specific niches, the example of that already occurs in other competitive sectors of the economy. Twelve potential forms for classifying large customers in electricity industry are presented: geographic localization; value of the invoice; sector of productive activity; types of share holding composition and enterprise management; forms and characteristics of the use of the electric energy in the final units; degree of technological sophistication; client relation cost benefit; common factors in energy process of purchase; brand associated with the customer; extraordinary factors, such as, urgency, application and volume of energy; personal characteristics of the purchaser in charge of the operation; former-customers who moved from the captive market to the free market and vice versa. The article concludes proposing a new methodology to identify the specific niches of customers in the electric sector, as well as the inductive and restrictive factors of this methodology. (author)

  9. Theoretical Foundation for Electric-Dipole-Allowed Chiral-Specific Fluorescence Optical Rotary Dispersion (F-ORD) from Interfacial Assemblies.

    Science.gov (United States)

    Deng, Fengyuan; Ulcickas, James R W; Simpson, Garth J

    2016-11-03

    Fluorescence optical rotary dispersion (F-ORD) is proposed as a novel chiral-specific and interface-specific spectroscopic method. F-ORD measurements of uniaxial assemblies are predicted to be fully electric-dipole-allowed, with corresponding increases in sensitivity to chirality relative to chiral-specific measurements in isotropic assemblies that are commonly interpreted through coupling between electric and magnetic dynamic dipoles. Observations of strong chiral sensitivity in prior single-molecule fluorescence measurements of chiral interfacial molecules are in excellent qualitative agreement with the predictions of the F-ORD mechanism and challenging to otherwise explain. F-ORD may provide methods to suppress background fluorescence in studies of biological interfaces, as the detected signal requires both polar local order and interfacial chirality. In addition, the molecular-level descriptions of the mechanisms underpinning F-ORD may also potentially apply to aid in interpreting chiral-specific Raman and surface-enhanced Raman spectroscopy measurements of uniaxially oriented assemblies, opening up opportunities for chiral-specific and interface-specific vibrational spectroscopy.

  10. Descriptive Study of Occupational Accidents and their Causes among Electricity Distribution Company Workers at an Eight-year Period in Iran

    Science.gov (United States)

    Rahmani, Abdolrasoul; Khadem, Monireh; Madreseh, Elham; Aghaei, Habib-Allah; Raei, Mehdi; Karchani, Mohsen

    2013-01-01

    Background Occupational accidents are unplanned events that cause damage. The socio-economic impacts and human costs of accidents are tremendous around the world. Many fatalities happen every year in workplaces such as electricity distribution companies. Some electrical injuries are electrocution, electric shock, and burns. This study was conducted in an electricity distribution company (with rotational 12-hour shift work) in Iran during an 8-year period to survey descriptive factors of injuries. Methods Variables collected included accident time, age of injured worker, employment type, work experience, injury cause, educational background, and other information about accidents. Results Results indicated that most of the accidents occurred in summer, and 51.3% were during shift work. Worker negligence (malpractice) was the cause of 75% of deaths. Type of employment had a significant relationship with type of injuries (p safety was related to job experiences. Temporary workers have no chance to work all year like permanent workers, therefore impressive experiences may be less in them. Because the lack of protective equipment and negligence are main causes of accidents, periodical inspections in workshops are necessary. PMID:24106647

  11. Specific features of well logging of boreholes drilled on electrical nonconducting solutions

    International Nuclear Information System (INIS)

    Ruchkin, A.F.; Fomenko, V.G.

    1978-01-01

    Methods for identification of permeable strata and determination of their porosity and oil-gas saturation using standard combination of geophysical investigations in the boreholes drilled with nonaqueous and inert drilling fluids are considered. Geophysical combination consists of the methods indications of which are independent on electrical conductivity of drilling fluids. They are all modifications of radioactivity logging (gamma logging, neutron logging, neutron-gamma logging, gamma-gamma logging, pulsed neutron logging, nuclear-magnetic logging), acoustic logging and thermal logging

  12. Specific features of electrical properties of porous biocarbons prepared from beech wood and wood artificial fiberboards

    Science.gov (United States)

    Popov, V. V.; Orlova, T. S.; Magarino, E. Enrique; Bautista, M. A.; Martínez-Fernández, J.

    2011-02-01

    This paper reports on comparative investigations of the structural and electrical properties of biomorphic carbons prepared from natural beech wood, as well as medium-density and high-density fiberboards, by means of carbonization at different temperatures T carb in the range 650-1000°C. It has been demonstrated using X-ray diffraction analysis that biocarbons prepared from medium-density and high-density fiberboards at all temperatures T carb contain a nanocrystalline graphite component, namely, three-dimensional crystallites 11-14 Å in size. An increase in the carbonization temperature T carb to 1000°C leads to the appearance of a noticeable fraction of two-dimensional graphene particles with the same sizes. The temperature dependences of the electrical resistivity ρ of the biomorphic carbons have been measured and analyzed in the temperature range 1.8-300 K. For all types of carbons under investigation, an increase in the carbonization temperature T carb from 600 to 900°C leads to a change in the electrical resistivity at T = 300 K by five or six orders of magnitude. The dependences ρ( T) for these materials are adequately described by the Mott law for the variable-range hopping conduction. It has been revealed that the temperature dependence of the electrical resistivity exhibits a hysteresis, which has been attributed to thermomechanical stresses in an inhomogeneous structure of the biocarbon prepared at a low carbonization temperature T carb. The crossover to the conductivity characteristic of disordered metal systems is observed at T carb ≳ 1000°C.

  13. High Fat Diet Administration during Specific Periods of Pregnancy Alters Maternal Fatty Acid Profiles in the Near-Term Rat

    Directory of Open Access Journals (Sweden)

    Marlon E. Cerf

    2016-01-01

    Full Text Available Excessive fat intake is a global health concern as women of childbearing age increasingly ingest high fat diets (HFDs. We therefore determined the maternal fatty acid (FA profiles in metabolic organs after HFD administration during specific periods of gestation. Rats were fed a HFD for the first (HF1, second (HF2, or third (HF3 week, or for all three weeks (HFG of gestation. Total maternal plasma non-esterified fatty acid (NEFA concentrations were monitored throughout pregnancy. At day 20 of gestation, maternal plasma, liver, adipose tissue, and placenta FA profiles were determined. In HF3 mothers, plasma myristic and stearic acid concentrations were elevated, whereas docosahexaenoic acid (DHA was reduced in both HF3 and HFG mothers. In HF3 and HFG mothers, hepatic stearic and oleic acid proportions were elevated; conversely, DHA and linoleic acid (LA proportions were reduced. In adipose tissue, myristic acid was elevated, whereas DHA and LA proportions were reduced in all mothers. Further, adipose tissue stearic acid proportions were elevated in HF2, HF3, and HFG mothers; with oleic acid increased in HF1 and HFG mothers. In HF3 and HFG mothers, placental neutral myristic acid proportions were elevated, whereas DHA was reduced. Further, placental phospholipid DHA proportions were reduced in HF3 and HFG mothers. Maintenance on a diet, high in saturated fat, but low in DHA and LA proportions, during late or throughout gestation, perpetuated reduced DHA across metabolic organs that adapt during pregnancy. Therefore a diet, with normal DHA proportions during gestation, may be important for balancing maternal FA status.

  14. Experimental Evaluation of Simple Thermal Storage Control Strategies in Low-Energy Solar Houses to Reduce Electricity Consumption during Grid On-Peak Periods

    Directory of Open Access Journals (Sweden)

    Kyoung-Ho Lee

    2015-08-01

    Full Text Available There is growing interest in zero-energy and low-energy buildings, which have a net energy consumption (on an annual basis of almost zero. Because they can generate both electricity and thermal energy through the use of solar photovoltaic (PV and solar thermal collectors, and with the help of reduced building thermal demand, low-energy buildings can not only make a significant contribution to energy conservation on an annual basis, but also reduce energy consumption and peak demand. This study focused on electricity consumption during the on-peak period in a low-energy residential solar building and considers the use of a building’s thermal mass and thermal storage to reduce electricity consumption in summer and winter by modulation of temperature setpoints for heat pump and indoor thermostats in summer and additional use of a solar heating loop in winter. Experiments were performed at a low-energy solar demonstration house that has solar collectors, hot water storage, a ground-coupled heat pump, and a thermal storage tank. It was assumed that the on-peak periods were from 2 pm to 5 pm on hot summer days and from 5 pm to 8 pm on cold winter days. To evaluate the potential for utilizing the building’s thermal storage capacity in space cooling and heating, the use of simple control strategies on three test days in summer and two test days in the early spring were compared in terms of net electricity consumption and peak demand, which also considered the electricity generation from solar PV modules on the roof of the house.

  15. Patient-specific electric field simulations and acceleration measurements for objective analysis of intraoperative stimulation tests in the thalamus

    Directory of Open Access Journals (Sweden)

    Simone Hemm-Ode

    2016-11-01

    Full Text Available Despite an increasing use of deep brain stimulation (DBS the fundamental mechanisms of action remain largely unknown. Simulation of electric entities has previously been proposed for chronic DBS combined with subjective symptom evaluations, but not for intraoperative stimulation tests. The present paper introduces a method for an objective exploitation of intraoperative stimulation test data to identify the optimal implant position of the chronic DBS lead by relating the electric field simulations to the patient-specific anatomy and the clinical effects quantified by accelerometry. To illustrate the feasibility of this approach, it was applied to five patients with essential tremor bilaterally implanted in the ventral intermediate nucleus (VIM. The VIM and its neighborhood structures were preoperatively outlined in 3D on white matter attenuated inversion recovery MR images. Quantitative intraoperative clinical assessments were performed using accelerometry. Electric field simulations (n = 272 for intraoperative stimulation test data performed along two trajectories per side were set-up using the finite element method for 143 stimulation test positions. The resulting electric field isosurface of 0.2V/mm was superimposed to the outlined anatomical structures. The percentage of volume of each structure's overlap was calculated and related to the corresponding clinical improvement. The proposed concept has been successfully applied to the five patients. For higher clinical improvements, not only the VIM but as well other neighboring structures were covered by the electric field isosurfaces. The percentage of the volumes of the VIM, of the nucleus intermediate lateral of the thalamus and the prelemniscal radiations within the prerubral field of Forel increased for clinical improvements higher than 50% compared to improvements lower than 50%. The presented new concept allows a detailed and objective analysis of a high amount of intraoperative data to

  16. Distribution of the solute in the lithium niobate crystal grown by the Stepanov method in a periodically changing external electric field

    International Nuclear Information System (INIS)

    Zhdanov, A.; Nikolayeva, L.; Red'kin, B.

    2000-01-01

    The Iithium niobate crystals with the periodic domain structure are characterised by the capacity for the light frequency adoption of the laser light. Consequently, they are promising for the development of compact light sources. There are several methods of producing periodic ferroelectric domain structures of the lithium niobate crystals in the growth process. It is evident that the main method of production of the periodic structures in the lithium niobate is the Stepanov method. The development of the mathematical model of the variation of the concentration of the alloying solute with the periodic variation of the conditions of growth of the crystal in the growth of the crystal by the Stepanov methods in the conditions of periodic changes of the drawing rate of the crystal V and the temperature of the thermal junction T have been investigated elsewhere. The formation of the domain structure is also possible in the case of the periodic variation of the electric field, during the supply of the alternating voltage between the shaper and the seed. In this work, we proposed mathematical model discounting the process of formation of the domain structure in the alternating electric field during the growth of the lithium niobate crystal by the Stepanov method. In the mathematical modelling we obtain the numerical solutions of the unidimensional nonstationary problem of the Stepanov type, the diffusion equation for concentration, and the Laplace capillary equation. The proposed mathematical model is at the present and the most complete and accurate description of the variation of the concentration of the solute in the growing crystal. The semi-discrete Galerkin method was used for the equations

  17. Specific features of a neonatal period in infants following intrauterine intravascular blood transfusion for fetal hemolytic disease

    Directory of Open Access Journals (Sweden)

    A. V. Ivanova

    2015-01-01

    Full Text Available The paper gives data on the characteristics of a neonatal period in infants following intrauterine blood transfusion for Rh-induced fetal hemolytic disease. It is shown that the early diagnosis and detection of the signs of fetal hemolytic disease, and intrauterine intravascular blood transfusion may prolong pregnancy, ensure the birth of a baby with normal anthropometric indicators, optimize his/her neonatal period and prognosis of severe hemolytic disease in the fetus and newborn.

  18. A chemical biology approach reveals period shortening of the mammalian circadian clock by specific inhibition of GSK-3beta.

    Science.gov (United States)

    Hirota, Tsuyoshi; Lewis, Warren G; Liu, Andrew C; Lee, Jae Wook; Schultz, Peter G; Kay, Steve A

    2008-12-30

    The circadian clock controls daily oscillations of gene expression at the cellular level. We report the development of a high-throughput circadian functional assay system that consists of luminescent reporter cells, screening automation, and a data analysis pipeline. We applied this system to further dissect the molecular mechanisms underlying the mammalian circadian clock using a chemical biology approach. We analyzed the effect of 1,280 pharmacologically active compounds with diverse structures on the circadian period length that is indicative of the core clock mechanism. Our screening paradigm identified many compounds previously known to change the circadian period or phase, demonstrating the validity of the assay system. Furthermore, we found that small molecule inhibitors of glycogen synthase kinase 3 (GSK-3) consistently caused a strong short period phenotype in contrast to the well-known period lengthening by lithium, another presumed GSK-3 inhibitor. siRNA-mediated knockdown of GSK-3beta also caused a short period, confirming the phenotype obtained with the small molecule inhibitors. These results clarify the role of GSK-3beta in the period regulation of the mammalian clockworks and highlight the effectiveness of chemical biology in exploring unidentified mechanisms of the circadian clock.

  19. Electricity and heat system development scenarios integrated in the energy system sustainable development in Romania in the period 2005 - 2025

    International Nuclear Information System (INIS)

    Marin, Otilia; Leca, Aureliu

    2004-01-01

    After 50 years of centralized economy, since 1989, Romania faces many challenges related to the internal conditions and to the new trends in energy markets over the world as: the existing low efficiency and availability, fast structural changes; the decentralization and privatization of the energy sector with new structures and entities; integration in EU and NATO structures. At present, with transition from the national vertical integrated monopolies to an open market, the determination of the global optimum development scenario of the power and heat sector becomes more important in order to find the policy which can lead the own strategies of different companies involved on market to a sustainable development of the society. The paper presents four long term development scenarios of the electricity and heat sector quantified from different points of view: technical, economical, environmental, social criteria, security of supply, risk diminishing etc and it continues by determining the long term global optimum development scenario integrated in the sustainable energy system. (authors)

  20. Electrical brain responses in language-impaired children reveal grammar-specific deficits.

    Directory of Open Access Journals (Sweden)

    Elisabeth Fonteneau

    2008-03-01

    Full Text Available Scientific and public fascination with human language have included intensive scrutiny of language disorders as a new window onto the biological foundations of language and its evolutionary origins. Specific language impairment (SLI, which affects over 7% of children, is one such disorder. SLI has received robust scientific attention, in part because of its recent linkage to a specific gene and loci on chromosomes and in part because of the prevailing question regarding the scope of its language impairment: Does the disorder impact the general ability to segment and process language or a specific ability to compute grammar? Here we provide novel electrophysiological data showing a domain-specific deficit within the grammar of language that has been hitherto undetectable through behavioural data alone.We presented participants with Grammatical(G-SLI, age-matched controls, and younger child and adult controls, with questions containing syntactic violations and sentences containing semantic violations. Electrophysiological brain responses revealed a selective impairment to only neural circuitry that is specific to grammatical processing in G-SLI. Furthermore, the participants with G-SLI appeared to be partially compensating for their syntactic deficit by using neural circuitry associated with semantic processing and all non-grammar-specific and low-level auditory neural responses were normal.The findings indicate that grammatical neural circuitry underlying language is a developmentally unique system in the functional architecture of the brain, and this complex higher cognitive system can be selectively impaired. The findings advance fundamental understanding about how cognitive systems develop and all human language is represented and processed in the brain.

  1. Standard Technical Specifications General Electric plants, BWR/4:Bases (Sections 3.4-3.10). Volume 3, Revision 1

    International Nuclear Information System (INIS)

    1995-04-01

    This report documents the results of the combined effort of the NRC and the industry to produce improved Standard Technical Specifications (STS), Revision 1 for General Electric BWR/4 Plants. The changes reflected in Revision 1 resulted from the experience gained from license amendment applications to convert to these improved STS or to adopt partial improvements to existing technical specifications. This NUREG is the result of extensive public technical meetings and discussions between the Nuclear Regulatory Commission (NRC) staff and various nuclear power plant licensees, Nuclear Steam Supply System (NSSS) Owners Groups, NSSS vendors, and the Nuclear Energy Institute (NEI). The improved STS were developed based on the criteria in the Final Commission Policy Statement on Technical Specifications Improvements for Nuclear Power Reactors, dated July 22, 1993. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume 1 contains the specifications for all chapters and sections of the improved STS. Volume 2 contains he Bases for Chapters 2.0 and 3.0, and Sections 3.1-3.3 of the improved STS. This document, Volume 3, contains the Bases for Sections 3.4-3.10 of the improved STS

  2. Standard Technical Specifications General Electric plants, BWR/4: Bases (Sections 2.0-3.3). Volume 2, Revision 1

    International Nuclear Information System (INIS)

    1995-04-01

    This report documents the results of the combined effort of the NRC and the industry produce improved Standard Technical Specifications (STS), Revision 1 for General Electric BWR/4 Plants. The changes reflected in Revision 1 resulted from the experience gained from license amendment applications to convert to these improved ST or to adopt partial improvements to existing technical specifications. This NUREG is the result of extensive public technical meetings and discussions between the Nuclear Regulatory Commission (NRC) staff and various nuclear power plant licensees, Nuclear Steam Supply System (NSSS) Owners Groups, NSSS vendors, and the Nuclear Energy Institute (NEI). The improved STS were developed based on the criteria in the Final Commission Policy Statement on Technical Specifications Improvements for Nuclear Power Reactors, dated July 22, 1993. The improved STS will be used as the basis for individual nuclear power plant licensees to develop improved plant-specific technical specifications. This report contains three volumes. Volume I contains the Specifications for all chapters and sections of the improved STS. This document, Volume 2, contains the Bases for Chapters 2.0 and 3.0, and Sections 3.1-3.3 of the improved STS. Volume 3 contains the Bases for Sections 3.4-3.10 of the improved STS

  3. Estimates of the relative specific yield of aquifers from geo-electrical ...

    African Journals Online (AJOL)

    This paper discusses a method of estimating aquifer specific yield based on surface resistivity sounding measurements supplemented with data on water conductivity. The practical aim of the method is to suggest a parallel low cost method of estimating aquifer properties. The starting point is the Archie's law, which relates ...

  4. Characterization of conditionally expressed mutants affecting age-specific Drosophila melanogaster : Lethal conditions and temperature-sensitive periods

    NARCIS (Netherlands)

    Vermeulen, CJ; Bijlsma, R

    The specific genetic basis of inbreeding depression is poorly understood. To address this question, two conditionally expressed lethal effects that were found to cause line-specific life span reductions in two separate inbred lines of Drosophila melanogaster. were characterized phenotypically and

  5. Specific absorption rate and electric field measurements in the near field of six mobile phone base station antennas.

    Science.gov (United States)

    Toivonen, Tommi; Toivo, Tim; Puranen, Lauri; Jokela, Kari

    2009-05-01

    In this article, the exposure to radio frequency electromagnetic fields was studied in close proximity (distances of 10, 100, 300, and 600 mm) to six base station antennas. The specific absorption rate (SAR) in 800 mm x 500 mm x 200 mm box phantom as well as unperturbed electric field (E) in air was measured. The results were used to determine whether the measurement of local maximum of unperturbed electric field can be used as a compliance check for local exposure. Also, the conservativeness of this assessment method compared to the ICNIRP basic restriction was studied. Moreover, the assessment of whole-body exposure was discussed and the distance ranges presented in which the ICNIRP limit for local exposure could be exceeded before the limit for whole-body SAR. These results show that the electric field measurement alone can be used for easy compliance check for the local exposure at all distances and for all antenna types studied. However, in some cases when the local peak value of E was compared directly to the ICNIRP reference level for unperturbed E, the exposure was overestimated only very slightly (by factor 1.1) compared to the basic restriction for localized SAR in a human, and hence these results can not be generalized to all antenna types. Moreover, it was shown that the limit for localized exposure could be exceeded before the limit for the whole-body average SAR, if the distance to the antenna was less than 240 mm. Copyright 2009 Wiley-Liss, Inc.

  6. Specification errors in estimating cost functions: the case of the nuclear-electric-generating industry

    International Nuclear Information System (INIS)

    Jorgensen, E.J.

    1987-01-01

    This study is an application of production-cost duality theory. Duality theory is reviewed for the competitive and rate-of-return regulated firm. The cost function is developed for the nuclear electric-power-generating industry of the United States using capital, fuel, and labor factor inputs. A comparison is made between the Generalized Box-Cox (GBC) and Fourier Flexible (FF) functional forms. The GBC functional form nests the Generalized Leontief, Generalized Square Root Quadratic and Translog functional forms, and is based upon a second-order Taylor-series expansion. The FF form follows from a Fourier-series expansion in sine and cosine terms using the Sobolev norm as the goodness-of-fit measure. The Sobolev norm takes into account first and second derivatives. The cost function and two factor shares are estimated as a system of equations using maximum-likelihood techniques, with Additive Standard Normal and Logistic Normal error distributions. In summary, none of the special cases of the GBC function form are accepted. Homotheticity of the underlying production technology can be rejected for both GBC and FF forms, leaving only the unrestricted versions supported by the data. Residual analysis indicates a slight improvement in skewness and kurtosis for univariate and multivariate cases when the Logistic Normal distribution is used

  7. Specific features of the electrical properties in partially graphitized porous biocarbons of beech wood

    Science.gov (United States)

    Popov, V. V.; Orlova, T. S.; Gutierrez-Pardo, A.; Ramirez-Rico, J.

    2015-09-01

    The electrical and galvanomagnetic properties of partially graphitized highly porous bioC(Ni) biocarbon matrices produced by pyrolysis (carbonization) of beech wood at temperatures T carb = 850-1600°C in the presence of a Ni-containing catalyst have been studied in comparison with their microstructural features. The temperature dependences of the resistivity, the magnetoresistance, and the Hall coefficient have been measured in the temperature range of 4.2-300 K in magnetic fields to 28 kOe. It has been shown that an additional graphite phase introduction into samples with T carb ≥ 1000°C results in an increase in the carrier mobility by a factor of 2-3, whereas the carrier (hole) concentration remains within ~1020 cm-3, as in biocarbons obtained without catalyst. An analysis of experimental data has demonstrated that the features of the conductivity and magnetoresistance of these samples are described by quantum corrections related to their structural features, i.e., the formation of a globular graphite phase of nano- and submicrometer sizes in the amorphous matrix. The quantum corrections to the conductivity decrease with increasing carbonization temperature, which indicates an increase in the degree of structure ordering and is in good agreement with microstructural data.

  8. Decision support for the definition of wind turbine systems adequacy to site specificities and weak electrical networks

    International Nuclear Information System (INIS)

    Arbaoui, A.

    2006-10-01

    A decision support system for the definition of wind turbine systems is developed by taking into account the wind and site characteristics, the wind turbine components and the electrical network properties close to the site. The approach is based on functional analysis, on the investigation of the functional fluxes and on the definition of a model suitable for supporting decision at the preliminary stages of wind turbine design. The complete set of solutions derived from the model is determined using a Constraint Satisfaction Problem solver. The intrinsic capability of the model to support decision is derived from the investigation of the model parsimony, precision, exactness and specialization. The model takes into account performance criteria resulting from knowledge of manufacturers, distributors and investors. These criteria are used to discriminate design alternatives. Design alternatives correspond to choices of site (wind, electric network) and wind turbine architectures (related to 7 design variables). Performance criteria are the cost of electric kWh, the amount of energy being produced and the discounted total cost of the project. Electric network connection to wind turbines is taken into account through slow variations of the voltage and Flickers phenomenon. First, the maximal rate of penetration of the wind turbine energy production is determined. Next, two design alternatives have been investigated to improve wind turbine system integration in electric distribution networks. These alternatives are a reactive power control system and an inertial energy storage system. Inertial storage systems seem to be more expensive than reactive power control systems for this type of application. The influence of site specificities on decision making process has been established through three different sites (a Mediterranean site and two sites located in northern Europe). Profits relative to the cost of kWh appear to be high for Mediterranean sites. Most of the

  9. A problem of optimization for the specific cost of installed electric power in nuclear plants

    Energy Technology Data Exchange (ETDEWEB)

    Sultan, M A; Khattab, M S [Reactors Dept. nuclear research centre, atomic energy authority, Cairo, (Egypt)

    1995-10-01

    The optimization problem analyzed in this paper is related to the thermal cycle parameters in nuclear power stations having steam generators. The optimization the specific cost of installed power with respect to the average operating saturation temperature in the station thermal cycle. The analysis considers the maximum fuel cladding temperature as a limiting factor in the optimization process as it is related to the safe operation of the reactor. 4 figs.

  10. Prebiotics enhance survival and prolong the retention period of specific probiotic inocula in an in vivo murine model.

    Science.gov (United States)

    Su, P; Henriksson, A; Mitchell, H

    2007-12-01

    To identify novel prebiotics that could be used to maintain persistence of three representative probiotic strains in vivo. Test mice were treated with prebiotics soybean oligosaccharide (SOS), fructooligosaccharide (FOS) or inulin, followed by probiotics Lactobacillus acidophilus LAFTI L10 (L10), Bifidobacterium lactis LAFTI B94 (B94) or Lactobacillus casei L26 LAFTI (L26). Faecal samples were then collected and analysed using selective medium and PCR analysis to determine the presence of the probiotic strains. In contrast to the control groups, in mice fed prebiotics, the survival and retention time of the test probiotics was increased extensively. SOS and FOS prolonged the retention period of L10 from 24 to 30 h. Of the three prebiotics, FOS gave the best result with B94, prolonging the retention period from 3 to > or =10 days. Of the three prebiotics, inulin gave the best result for L26, prolonging the retention period from 2 to > or =6 days. The prebiotics SOS, FOS and inulin significantly enhance survival and prolong the retention period of L10, B94 and L26 in vivo. Our results demonstrate the potential use of FOS, inulin and SOS as prebiotics in conjunction with the probiotic strains L10, B94 and L26 for new synbiotic products.

  11. Dose-specific effects of transcutaneous electrical nerve stimulation (TENS) on experimental pain: a systematic review.

    Science.gov (United States)

    Claydon, Leica S; Chesterton, Linda S; Barlas, Panos; Sim, Julius

    2011-09-01

    To determine the hypoalgesic effects of transcutaneous electrical nerve stimulation (TENS) parameter combinations on experimental models in healthy humans. Searches were performed using the electronic databases Ovid MEDLINE, CINAHL, AMED, and Web of Science (from inception to December 2009). Manual searches of journals and reference lists of retrieved trials were also performed. Randomized controlled trials (RCTs) were included in the review if they compared the hypoalgesic effect of TENS relative with placebo and control, using an experimental pain model in healthy human participants. Two reviewers independently selected the trials, assessed their methodologic quality and extracted data. Forty-three RCTs were eligible for inclusion. A best evidence synthesis revealed: Overall "conflicting" (inconsistent findings in multiple RCTs) evidence of TENS efficacy on experimental pain irrespective of TENS parameters used. Overall intense TENS has "moderate" evidence of efficacy (1 high-quality and 2 low-quality trials). Conventional TENS has overall conflicting evidence of efficacy, this is derived from "strong" evidence of efficacy (generally consistent findings in multiple high-quality RCTs) on pressure pain but strong evidence of inefficacy on other pain models. "Limited" evidence (positive findings from 1 RCT) of hypoalgesia exists for some novel parameters. Low-intensity, low-frequency, local TENS has strong evidence of inefficacy. Inappropriate TENS (using "barely perceptible" intensities) has moderate evidence of inefficacy. The level of hypoalgesic efficacy of TENS is clearly dependent on TENS parameter combination selection (defined in terms of intensity, frequency, and stimulation site) and experimental pain model. Future clinical RCTs may consider these TENS dose responses.

  12. Specifics of energy-saving technologies in electrical power supply systems of operating industrial enterprises

    OpenAIRE

    Кирисов, Игорь Геннадиевич; Овчаренко, Татьяна Ивановна

    2014-01-01

    В статье рассмотрены особенности разных энергосберегающих технологий, которые можно применить в системах электроснабжения промышленных предприятий. Проведены расчеты, подтверждающие целесообразность замены недозагруженных асинхронных двигателей на двигатели меньшей мощности. The paper deals with the speci cs of different energy-saving technologies that can be applied in electrical power supply systems of industrial enterprises. The paper presents calculations that corroborate ...

  13. Survey on Different Samsung with Nokia Smart Mobile Phones in the Specific Absorption Rate Electrical Field of Head.

    Science.gov (United States)

    Fakhri, Yadolah; Alinejad, Azim; Keramati, Hassan; Bay, Abotaleb; Avazpour, Moayed; Zandsalimi, Yahya; Moradi, Bigard; Rasouli Amirhajeloo, Leila; Mirzaei, Maryam

    2016-09-01

    The use of smart phones is increasing in the world. This excessive use, especially in the last two decades, has created too much concern on the effects of emitted electromagnetic fields and specific absorption rate on human health. In this descriptive-analytical study of the electric field resulting from smart phones of Samsung and Nokia by portable measuring device, electromagnetic field, Model HI-3603-VDT/VLF, were measured. Then, head absorption rate was calculated in these two mobiles by ICNIRP equation. Finally, the comparison of specific absorption rate, especially between Samsung and Nokia smart phones, was conducted by T-Test statistics analysis. The mean of electric field for Samsung and Nokia smart mobile phones was obtained 1.8 ±0.19 v/m  and 2.23±0.39 v/m , respectively, while the range of the electric field was obtained as 1.56-2.21 v/m and 1.69-2.89 v/m for them, respectively. The mean of specific absorption rate in Samsung and Nokia was obtained 0.002 ± 0.0005 W/Kg and 0.0041±0.0013 W/Kg at the frequency of 900 MHz and 0.004±0.001 W/Kg and 0.0062±0.0002 W/Kg at the frequency of 1800 MHz respectively. The ratio of mean electronic field to guidance in the Samsung mobile phone at the frequency of 900 MHz and 1800 MHz was 4.36% and 3.34%, while was 5.62% and 4.31% in the Nokia mobile phone, respectively. The ratio of mean head specific absorption rate in smart mobile phones of Samsung and Nokia in the guidance level at the frequency of 900 was 0.15% and 0.25%, respectively, while was 0.23 %and 0.38% at the frequency of 1800 MHz, respectively. The rate of specific absorption of Nokia smart  mobile phones at the frequencies of 900 and 1800 MHz  was significantly higher than Samsung (p value Samsung smart mobile phone.

  14. Order-Specific Fertility Rates for Germany
    Estimates from Perinatal Statistics for the Period 2001-2008

    OpenAIRE

    Michaela Kreyenfeld; Rembrandt Scholz; Frederik Peters; Ines Wlosnewski

    2011-01-01

    Until 2008, Germany’s vital statistics did not include information on the biological order of each birth. This resulted in a dearth of important demographic indicators, such as the mean age at first birth and the level of childlessness. Researchers have tried to fill this gap by generating order-specific birth rates from survey data, and by combining survey data with vital statistics. This paper takes a different approach by using Perinatal Statistics to generate birth order-specific fertilit...

  15. Comparative study of long-period gratings written in a boron co-doped fiber by an electric arc and UV irradiation

    International Nuclear Information System (INIS)

    Smietana, M; Bock, W J; Mikulic, P

    2010-01-01

    The paper presents for the first time a comparative study of long-period gratings (LPGs) written by point-by-point UV irradiation and by electrical arc discharges. These gratings were inscribed in a highly photosensitive boron co-doped fiber that can be considered as a suitable platform for LPG writing using either technology. The experimental transmission data for the manufactured LPG devices fit well when compared to the simulations we carried out in parallel. As a result of each of these writing processes, we were able to obtain a remarkably good quality of grating. Two reasons could explain the observed small differences between the spectra: a slight mismatch of the period of the gratings and an unintentional tapering of the fiber during the arc-based processes. We also found that the UV irradiation at λ = 248 nm can cause clearly visible damage to the fiber's surface. As a result of the UV writing, a coupling to the asymmetrical cladding modes can take place. Moreover, the gratings written using the two technologies show a very similar refractive index and temperature-sensing properties. The only differences between them can come from a physical deformation of the fiber induced by the electric arc discharges

  16. Results of evaluation of periodic safety review for No. 1 plant in Fukushima No. 1 Nuclear Power Station, Tokyo Electric Power Co., Inc

    International Nuclear Information System (INIS)

    1994-01-01

    No. 1 plant in Fukushima No. 1 Nuclear Power Station started the commercial power generation in March, 1971, and has continued the operation for more than 23 years. During this period, the countermeasures to troubles, periodic inspections, and the maintenance by the electric power company have been carried out. These states are to be recollected from the viewpoints of the comprehensive evaluation of the operation experiences and the reflection of the latest technological knowledge, and the safety and reliability are to be further improved in the periodic safety review. Agency of Natural Resources and Energy evaluated the report of the periodic safety review for No. 1 plant in Fukushima No. 1 Nuclear Power Station, and summarized the results. The course of the evaluation of the report is shown. The facility utilization factor was 50.1% on the average of about 23 years, but in the last 10 years, it was improved to 59.7%. In the last five years, the rate of occurrence of unexpected shutdown was 0.4 times/year. These are the results of preventive maintenance and the improvement of the facilities and operation management. Operation management, maintenance management, fuel management, radiation control, radioactive waste management and the reflection of the experience of troubles and the latest technological knowledge to the improvement of safety have been carried out properly. The work plan for disaster prevention was established. (K.I.)

  17. Technical specifications, Vogtle Electric Generating Plant, Unit No. 1 (Docket No. 50-424): Appendix ''A'' to license No. NPF-61

    International Nuclear Information System (INIS)

    1987-01-01

    This technical specifications report presents information concerning the Vogtle Electric Generating Plant in the following areas: safety limits and limiting safety system settings; limiting conditions for operation and surveillance requirements; design features; and administrative controls

  18. Neuron class-specific requirements for Fragile X Mental Retardation Protein in critical period development of calcium signaling in learning and memory circuitry.

    Science.gov (United States)

    Doll, Caleb A; Broadie, Kendal

    2016-05-01

    Neural circuit optimization occurs through sensory activity-dependent mechanisms that refine synaptic connectivity and information processing during early-use developmental critical periods. Fragile X Mental Retardation Protein (FMRP), the gene product lost in Fragile X syndrome (FXS), acts as an activity sensor during critical period development, both as an RNA-binding translation regulator and channel-binding excitability regulator. Here, we employ a Drosophila FXS disease model to assay calcium signaling dynamics with a targeted transgenic GCaMP reporter during critical period development of the mushroom body (MB) learning/memory circuit. We find FMRP regulates depolarization-induced calcium signaling in a neuron-specific manner within this circuit, suppressing activity-dependent calcium transients in excitatory cholinergic MB input projection neurons and enhancing calcium signals in inhibitory GABAergic MB output neurons. Both changes are restricted to the developmental critical period and rectified at maturity. Importantly, conditional genetic (dfmr1) rescue of null mutants during the critical period corrects calcium signaling defects in both neuron classes, indicating a temporally restricted FMRP requirement. Likewise, conditional dfmr1 knockdown (RNAi) during the critical period replicates constitutive null mutant defects in both neuron classes, confirming cell-autonomous requirements for FMRP in developmental regulation of calcium signaling dynamics. Optogenetic stimulation during the critical period enhances depolarization-induced calcium signaling in both neuron classes, but this developmental change is eliminated in dfmr1 null mutants, indicating the activity-dependent regulation requires FMRP. These results show FMRP shapes neuron class-specific calcium signaling in excitatory vs. inhibitory neurons in developing learning/memory circuitry, and that FMRP mediates activity-dependent regulation of calcium signaling specifically during the early

  19. A High-Performance Application Specific Integrated Circuit for Electrical and Neurochemical Traumatic Brain Injury Monitoring.

    Science.gov (United States)

    Pagkalos, Ilias; Rogers, Michelle L; Boutelle, Martyn G; Drakakis, Emmanuel M

    2018-05-22

    This paper presents the first application specific integrated chip (ASIC) for the monitoring of patients who have suffered a Traumatic Brain Injury (TBI). By monitoring the neurophysiological (ECoG) and neurochemical (glucose, lactate and potassium) signals of the injured human brain tissue, it is possible to detect spreading depolarisations, which have been shown to be associated with poor TBI patient outcome. This paper describes the testing of a new 7.5 mm 2 ASIC fabricated in the commercially available AMS 0.35 μm CMOS technology. The ASIC has been designed to meet the demands of processing the injured brain tissue's ECoG signals, recorded by means of depth or brain surface electrodes, and neurochemical signals, recorded using microdialysis coupled to microfluidics-based electrochemical biosensors. The potentiostats use switchedcapacitor charge integration to record currents with 100 fA resolution, and allow automatic gain changing to track the falling sensitivity of a biosensor. This work supports the idea of a "behind the ear" wireless microplatform modality, which could enable the monitoring of currently non-monitored mobile TBI patients for the onset of secondary brain injury. ©2018 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  20. Energy policy strategies of the Baltic Sea Region for the post-Kyoto period - focusing on electricity and district heating generation

    Energy Technology Data Exchange (ETDEWEB)

    2012-05-15

    This study presents a comprehensive analysis of energy policy strategies for the Baltic Sea Region for the post-Kyoto period. To this aim, the study provides scenarios for the region in order to develop a both secure and climate-compatible energy system for the year 2020 and beyond. The long-term development of the energy systems in the Baltic Sea Region is analysed, i.e. in Denmark, Estonia, Finland, Germany, Latvia, Lithuania, Norway, Poland, Sweden, and the north western part of Russia. The study focuses on the electricity and district heating sectors. The Baltic Sea Region is comprised of countries with very different economies and characteristics. Hydropower is an important source of electricity generation in Norway, Sweden, Finland and Latvia. Biomass resources are significant throughout the region, deriving from both agricultural residues and large forested areas. Wind power already contributes considerably to electricity generation in countries such as Denmark and Germany, and is likely to play a much greater role in the region in the years to come, both onshore and offshore. In the longer term (2030 and beyond), solar power and geothermal energy could also provide notable contributions to the overall energy supply. The study shows that it is technically possible to reduce greenhouse gas emissions in the electricity and district heating sectors of the Baltic Sea Region by close to 100% using mainly renewable energy sources. The results indicate that this is a challenging, but manageable task. The associated costs are moderate and can be further decreased through regional cooperation. Once the various production technologies have the possibility to interact with district heating and flexible electricity consumption, and transmission connections are optimally utilised, it becomes realistic to integrate e.g. large volumes of wind power into the energy system as a whole. Furthermore, the hydro power reservoirs, particularly in Norway, play a key role in

  1. Non-conventional rule of making a periodically varying different-pole magnetic field in low-power alternating current electrical machines with using ring coils in multiphase armature winding

    Science.gov (United States)

    Plastun, A. T.; Tikhonova, O. V.; Malygin, I. V.

    2018-02-01

    The paper presents methods of making a periodically varying different-pole magnetic field in low-power electrical machines. Authors consider classical designs of electrical machines and machines with ring windings in armature, structural features and calculated parameters of magnetic circuit for these machines.

  2. Sex-specific mouse liver gene expression: genome-wide analysis of developmental changes from pre-pubertal period to young adulthood

    Directory of Open Access Journals (Sweden)

    Conforto Tara L

    2012-04-01

    Full Text Available Abstract Background Early liver development and the transcriptional transitions during hepatogenesis are well characterized. However, gene expression changes during the late postnatal/pre-pubertal to young adulthood period are less well understood, especially with regards to sex-specific gene expression. Methods Microarray analysis of male and female mouse liver was carried out at 3, 4, and 8 wk of age to elucidate developmental changes in gene expression from the late postnatal/pre-pubertal period to young adulthood. Results A large number of sex-biased and sex-independent genes showed significant changes during this developmental period. Notably, sex-independent genes involved in cell cycle, chromosome condensation, and DNA replication were down regulated from 3 wk to 8 wk, while genes associated with metal ion binding, ion transport and kinase activity were up regulated. A majority of genes showing sex differential expression in adult liver did not display sex differences prior to puberty, at which time extensive changes in sex-specific gene expression were seen, primarily in males. Thus, in male liver, 76% of male-specific genes were up regulated and 47% of female-specific genes were down regulated from 3 to 8 wk of age, whereas in female liver 67% of sex-specific genes showed no significant change in expression. In both sexes, genes up regulated from 3 to 8 wk were significantly enriched (p p Ihh; female-specific Cdx4, Cux2, Tox, and Trim24 and may contribute to the developmental changes that lead to global acquisition of liver sex-specificity by 8 wk of age. Conclusions Overall, the observed changes in gene expression during postnatal liver development reflect the deceleration of liver growth and the induction of specialized liver functions, with widespread changes in sex-specific gene expression primarily occurring in male liver.

  3. Attributing impacts to emissions traced to major fossil energy and cement producers over specific historical time periods

    Science.gov (United States)

    Ekwurzel, B.; Frumhoff, P. C.; Allen, M. R.; Boneham, J.; Heede, R.; Dalton, M. W.; Licker, R.

    2017-12-01

    Given the progress in climate change attribution research over the last decade, attribution studies can inform policymakers guided by the UNFCCC principle of "common but differentiated responsibilities." Historically this has primarily focused on nations, yet requests for information on the relative role of the fossil energy sector are growing. We present an approach that relies on annual CH4 and CO2 emissions from production through to the sale of products from the largest industrial fossil fuel and cement production company records from the mid-nineteenth century to present (Heede 2014). Analysis of the global trends with all the natural and human drivers compared with a scenario without the emissions traced to major carbon producers over full historical versus select periods of recent history can be policy relevant. This approach can be applied with simple climate models and earth system models depending on the type of climate impacts being investigated. For example, results from a simple climate model, using best estimate parameters and emissions traced to 90 largest carbon producers, illustrate the relative difference in global mean surface temperature increase over 1880-2010 after removing these emissions from 1980-2010 (29-35%) compared with removing these emissions over 1880-2010 (42-50%). The changing relative contributions from the largest climate drivers can be important to help assess the changing risks for stakeholders adapting to and reducing exposure and vulnerability to regional climate change impacts.

  4. Electrical stimulation with periodic alternating intervals stimulates neuronal cells to produce neurotrophins and cytokines through activation of mitogen-activated protein kinase pathways.

    Science.gov (United States)

    Yamamoto, Kenta; Yamamoto, Toshiro; Honjo, Kenichi; Ichioka, Hiroaki; Oseko, Fumishige; Kishida, Tsunao; Mazda, Osam; Kanamura, Narisato

    2015-12-01

    Peripheral neuropathy is a representative complication of dental surgery. Electrical therapy, based on electrical stimulation with periodic alternating intervals (ES-PAI), may promote nerve regeneration after peripheral nerve injury in a non-invasive manner, potentially providing an effective therapy for neuropathy. This study aimed to analyze the molecular mechanisms underlying the nerve recovery stimulated by ES-PAI. In brief, ES-PAI was applied to a neuronal cell line, Neuro2A, at various intensities using the pulse generator apparatus, FREUDE. Cell viability, neurotrophin mRNA expression, and cytokine production were examined using a tetrazolium-based assay, real-time RT-PCR, and ELISA, respectively. Mitogen-activated protein kinase (MAPK) signaling was assessed using flow cytometry. It was found that ES-PAI increased the viability of cells and elevated expression of nerve growth factor (NGF) and neurotrophin-3 (NT-3); ESPAI also augmented vascular endothelial growth factor (VEGF) and platelet-derived growth factor (PDGF) expression, which was restored by addition of p38 inhibitors. Phosphorylation of p38 and extracellular signal-regulated kinase 1/2 (ERK-1/2) was augmented by ES-PAI. Hence, ES-PAI may ameliorate peripheral neuropathy by promoting neuronal cell proliferation and production of neurogenic factors by activating p38 and ERK-1/2 pathways. © 2015 Eur J Oral Sci.

  5. Improving a Complement-fixation Test for Equine Herpesvirus Type-1 by Pretreating Sera with Potassium Periodate to Reduce Non-specific Hemolysis

    Science.gov (United States)

    BANNAI, Hiroshi; NEMOTO, Manabu; TSUJIMURA, Koji; YAMANAKA, Takashi; KONDO, Takashi; MATSUMURA, Tomio

    2013-01-01

    Non-specific hemolysis has often been observed during complement-fixation (CF) tests for equine herpesvirus type-1 (EHV-1), even when the sera have virus-specific CF antibodies. This phenomenon has also been reported in CF tests for various infectious diseases of swine. We found that the sera from 22 of 85 field horses (25.9%) showed non-specific hemolysis during conventional CF testing for EHV-1. Because pretreatment of swine sera with potassium periodate (KIO4) improves the CF test for swine influenza, we applied this method to horse sera. As we expected, horse sera treated with KIO4 did not show non-specific hemolysis in the EHV-1 CF test, and precise determination of titers was achieved. PMID:24834005

  6. Specific Intensity Direct Current (DC) Electric Field Improves Neural Stem Cell Migration and Enhances Differentiation towards βIII-Tubulin+ Neurons

    Science.gov (United States)

    Zhao, Huiping; Steiger, Amanda; Nohner, Mitch; Ye, Hui

    2015-01-01

    Control of stem cell migration and differentiation is vital for efficient stem cell therapy. Literature reporting electric field–guided migration and differentiation is emerging. However, it is unknown if a field that causes cell migration is also capable of guiding cell differentiation—and the mechanisms for these processes remain unclear. Here, we report that a 115 V/m direct current (DC) electric field can induce directional migration of neural precursor cells (NPCs). Whole cell patching revealed that the cell membrane depolarized in the electric field, and buffering of extracellular calcium via EGTA prevented cell migration under these conditions. Immunocytochemical staining indicated that the same electric intensity could also be used to enhance differentiation and increase the percentage of cell differentiation into neurons, but not astrocytes and oligodendrocytes. The results indicate that DC electric field of this specific intensity is capable of promoting cell directional migration and orchestrating functional differentiation, suggestively mediated by calcium influx during DC field exposure. PMID:26068466

  7. The linear and nonlinear response of infinite periodic systems to static and/or dynamic electric fields. Implementation in CRYSTAL code

    Energy Technology Data Exchange (ETDEWEB)

    Kirtman, Bernard [Department of Chemistry and Biochemistry, University of California, Santa Barbara, California 93106 (United States); Springborg, Michael [Physical and Theoretical Chemistry, University of Saarland, 66123 Saarbrücken (Germany); Rérat, Michel [Equipe de Chimie Physique, IPREM UMR5254, Université de Pau et des Pays de l' Adour, 64000 Pau (France); Ferrero, Mauro; Lacivita, Valentina; Dovesi, Roberto [Departimeno di Chimica, IFM, Università di Torino and NIS - Nanostructure Interfaces and Surfaces - Centre of Excellence, Via P. Giuria 7, 10125 Torino (Italy); Orlando, Roberto [Departimento di Scienze e Tecnologie Avanzati, Università del Piemonte Orientale, Viale T. Michel 11, 15121 Alessandria (Italy)

    2015-01-22

    An implementation of the vector potential approach (VPA) for treating the response of infinite periodic systems to static and dynamic electric fields has been initiated within the CRYSTAL code. The VPA method is based on the solution of a time-dependent Hartree-Fock or Kohn-Sham equation for the crystal orbitals wherein the usual scalar potential, that describes interaction with the field, is replaced by the vector potential. This equation may be solved either by perturbation theory or by finite field methods. With some modification all the computational procedures of molecular ab initio quantum chemistry can be adapted for periodic systems. Accessible properties include the linear and nonlinear responses of both the nuclei and the electrons. The programming of static field pure electronic (hyper)polarizabilities has been successfully tested. Dynamic electronic (hyper)polarizabilities, as well as infrared and Raman intensities, are in progress while the addition of finite fields for calculation of vibrational (hyper)polarizabilities, through nuclear relaxation procedures, will begin shortly.

  8. Evaluating the approach to reduce the overrun cost of grid connected PV systems for the Spanish electricity sector: Performance analysis of the period 2010–2012

    International Nuclear Information System (INIS)

    Hoz, Jordi de la; Martín, Helena; Ballart, Jordi; Monjo, Lluis

    2014-01-01

    Highlights: • The cost of the Spanish PV promotion policy from 1998 to 2008 is formulated. • The range of scenarios for the cost evolution is determined. • The PV legal measures addressed to reduce the cost are formulated. • The savings range for the Spanish electricity sector has been determined. • The profitability loss of the facilities due to cost containment measures is assessed. - Abstract: A methodology for calculating the overrun cost to the Spanish electricity system caused by the large overshoot of the PV power targets under the RD 661/2007 is here presented. The elements influencing the cost have been identified, which has allowed proposing different scenarios for its possible evolution. Applying the same methodology, the range of savings achievable by the new energy policy developed in 2010–2012 to reduce this cost has been quantified. Inverting the point of view, the profitability reduction that these energy measures might have caused on the PV facilities has been also assessed. The conclusions obtained from the case of four specific facilities may give some insight about the general economic effects on the installations of the 2010–2012 new energy policy, and the consequences for the investors when the inadequacies of the regulatory schemes are tried to be corrected ex-post

  9. Assessment of the prevalence of occupational accidents and their influential actors in an electricity distribution company during a five-year period.

    Science.gov (United States)

    Sadeghain, Marzieh; Farid, Ramin Ataei; Dormohammadi, Ali; Aghaei, Habib Allah; Rahmani, Abdolrasoul; Farhadi, Rozita; Eskandari, Rasoul; Karchani, Mohsen

    2013-01-01

    Occupational accidents have been considered as one of the most important crippling factors contributing to disabilities and life-threatening situations in many countries. This study was conducted to survey the prevalence of occupational accidents and the factors of that lead to injuries in an Electricity Distribution Company during a five-year period. In this descriptive study, the accident report form included items asking about the season of the year when the accident occurred, the ages and the average age of those injured, the type of employment, work experience, nature of the injuries that occurred, parts of the body affected, treatments that were applied, average number of days lost per accident, the levels of education of those involved, and their marital status. Data was analyzed using SPSS. A total of 66 Electricity Distribution Company workers were determined to be suffering from injuries due to accidents. The accidents mostly occurred in the summer (33%). Most of the injured workers (16.7%) belonged to the age groups of 25 to 29 and 40 to 44; there were no accidents reported for workers who were less than 20. About 48% of the accident victims had to be hospitalized. Furthermore, 35% of the accident victims were treated in outpatient clinics, and 7.4% of the accident victims died. We demonstrated that there were significant relationships between: 1) marital status and accidental injuries (P0.05) or work experience and the distribution of the accidents (P>0.05). This study indicated that most of the injuries in these accidents were related to the nature of employment, marital status, and level of education. The results showed the necessity for providing appropriate safety training for the workers.

  10. Assessment of the prevalence of occupational accidents and their influential actors in an electricity distribution company during a five-year period

    Science.gov (United States)

    Sadeghain, Marzieh; Farid, Ramin Ataei; Dormohammadi, Ali; Aghaei, Habib Allah; Rahmani, Abdolrasoul; Farhadi, Rozita; Eskandari, Rasoul; Karchani, Mohsen

    2013-01-01

    Background: Occupational accidents have been considered as one of the most important crippling factors contributing to disabilities and life-threatening situations in many countries. This study was conducted to survey the prevalence of occupational accidents and the factors of that lead to injuries in an Electricity Distribution Company during a five-year period. Methods: In this descriptive study, the accident report form included items asking about the season of the year when the accident occurred, the ages and the average age of those injured, the type of employment, work experience, nature of the injuries that occurred, parts of the body affected, treatments that were applied, average number of days lost per accident, the levels of education of those involved, and their marital status. Data was analyzed using SPSS. Results: A total of 66 Electricity Distribution Company workers were determined to be suffering from injuries due to accidents. The accidents mostly occurred in the summer (33%). Most of the injured workers (16.7%) belonged to the age groups of 25 to 29 and 40 to 44; there were no accidents reported for workers who were less than 20. About 48% of the accident victims had to be hospitalized. Furthermore, 35% of the accident victims were treated in outpatient clinics, and 7.4% of the accident victims died. We demonstrated that there were significant relationships between: 1) marital status and accidental injuries (P0.05) or work experience and the distribution of the accidents (P>0.05). Conclusion: This study indicated that most of the injuries in these accidents were related to the nature of employment, marital status, and level of education. The results showed the necessity for providing appropriate safety training for the workers. PMID:26120397

  11. Electricity mix and ecological assessments. Consequences of the choice of specific electricity mixes in analyses of the environmental performance of products and services; Strommix in Oekobilanzen. Auswirkungen der Strommodellwahl fuer Produkt- und Betriebs-Oekobilanzen

    Energy Technology Data Exchange (ETDEWEB)

    Menard, M.; Dones, R.; Gantner, U

    1998-12-01

    The study aims at analysing the methodological issues associated with the definition of electricity mixes and discussing the consequences of the choice of specific electricity mixes in analyses of the environmental performance of products and services, based on Life Cycle Assessment (LCA). This report has been designed as a guideline to support LCA practitioners in the systematic identification of the most appropriate electricity mixes for LCA applications. A detailed checklist has been developed for this purpose. It includes the following items: type of electricity supply (from the net, self production, direct contracts); voltage level; country/place of utilisation; year of utilisation; season/daytime of utilisation; import/export model; and, marginal vs. average approach. A few examples, utilising published LCA studies, illustrate the impacts of the insights gained in the present work. Although primarily aimed at applications in Switzerland, the main concepts, the modelling and parts of the information provided can also be applied to other European countries. In addition to the three models proposed earlier for the assessment of the Swiss yearly average electricity mix, a new model (M4) has been developed in the frame of the present task in order to take into account the conditions characteristic for Switzerland as a transit land for electricity trades between its neighbour countries. All existing electricity mix models as well as selected environmental inventories are described and compared in the report. As an example of results, the CO{sub 2} emissions calculated for the Swiss yearly electricity supply mix are relatively small (48 g/kWh with model M4, as compared with 497 g/kWh for the average UCPTE mix). Key information on the structure of electricity generation and trade in Europe is provided. The modelling of the electricity supply for most of the European countries is less sensitive to the choice of an electricity model than for Switzerland. Considering

  12. A pilot study on using acupuncture and transcutaneous electrical nerve stimulation to treat chronic non-specific low back pain.

    Science.gov (United States)

    Itoh, Kazunori; Itoh, Satoko; Katsumi, Yasukazu; Kitakoji, Hiroshi

    2009-02-01

    The present study tests whether a combined treatment of acupuncture and transcutaneous electrical nerve stimulation (TENS) is more effective than acupuncture or TENS alone for treating chronic low back pain (LBP). Thirty-two patients with chronic LBP were randomly allocated to four groups. The acupuncture group (ACP) received only acupuncture treatment at selected acupoints for low back pain; the TENS group (TENS) received only TENS treatment at pain areas; the acupuncture and TENS group (A&T) received both acupuncture and TENS treatments; the control group (CT) received topical poultice (only when necessary). Each group received specific weekly treatment five times during the study. Outcome measures were pain intensity in terms of visual analogue scale (VAS) and QOL of low back in terms of Roland-Morris Disability Questionnaire (RDQ). The ACP, TENS and A&T groups all reported lower VAS and RDQ scores. Significant reduction in pain intensity (PTENS treatment is effective in pain relief and QOL of low back improvement for the sampled patients suffering from chronic LBP.

  13. Electrical stimulation for chronic non-specific low back pain in a working-age population: a 12-week double blinded randomized controlled trial.

    Science.gov (United States)

    Thiese, Matthew S; Hughes, Matthew; Biggs, Jeremy

    2013-03-28

    Non-invasive electrotherapy is commonly used for treatment of chronic low back pain. Evidence for efficacy of most electrotherapy modalities is weak or lacking. This study aims to execute a high-quality, double-blinded randomized controlled clinical trial comparing 1) H-Wave(®) Device stimulation plus usual care with 2) transcutaneous electrical nerve stimulation (TENS) plus usual care, and 3) Sham electrotherapy plus usual care to determine comparative efficacy for treatment of chronic non-specific low back pain patients. Chronic non-specific low back pain patients between ages of 18-65 years, with pain of at least 3 months duration and minimal current 5/10 VAS pain. Patients will have no significant signs or symptoms of lumbosacral nerve impingement, malignancy, spinal stenosis, or mood disorders. Double blind RCT with 3 arms and 38 subjects per arm. Randomization by permuted blocks of random length, stratified by Workers Compensation claim (yes vs. no), and use of opioids. The null hypothesis of this study is that there are no statistically significant differences in functional improvement between treatment types during and at the end of a 12-week week treatment period. Subjective data will be collected using Filemaker Pro™ database management collection tools. Objective data will be obtained through functional assessments. Data will be collected at enrollment and at 1, 4, 8, and 12 weeks for each participant by a blinded assessor. H-Wave(®) device stimulation (Intervention A) plus usual care, transcutaneous electrical nerve stimulation (TENS) (Intervention B) plus usual care, and sham electrotherapy plus usual care (control). Each treatment arm will have identical numbers of visits (4) and researcher contact time (approximately 15 hours). Oswestry Disability Index. Secondary measures include: Rowland Morris Instrument, VAS pain score, functional evaluation including strength when pushing and pulling, pain free range of motion in flexion and extension

  14. [Specific features of the functional state of the cardiorespiratory system in athletes differing in the types of muscular activity during the preparatory period of the training cycle].

    Science.gov (United States)

    Ivanova, N B

    2011-01-01

    The present study of the functional state of the cadiorespiratory system included athletes engaged in cyclic team sports. The state of the cardiorespiratory system was estimated from the measurement of central hemodynamics and cardiac rhythm variability, results of electrocardiography, spirography, and pneumotachography performed during the preparatory period for the training cycle. It was shown that the cardiovascular and respiratory systems as well as vegetative regulation of the cardiac rhythm of the athletes under examination underwent differently directed structural modification depending on the specific patterns of muscular activity.

  15. Technical specifications: Susquehanna Steam Electric Station, Unit No. 2 (Docket No. 50-388). Appendix A to License No. NPF-22

    International Nuclear Information System (INIS)

    1984-03-01

    Susquehanna Steam Electric Station, Unit 2 Technical Specifications were prepared by the US Nuclear Regulatory Commission to set forth the limits, operating conditions, and other requirements applicable to a nuclear reactor facility as set forth in Section 50.36 of 10 CFR Part 50 for the protection of the health and safety of the public

  16. Comparing equivalent thermal, high pressure and pulsed electric field processes for mild pasteurization of orange juice: Part II: Impact on specific chemical and biochemical quality parameters

    NARCIS (Netherlands)

    Vervoort, L.; Plancken, van der I.; Grauwet, T.; Timmermans, R.A.H.; Mastwijk, H.C.; Matser, A.M.; Hendrickx, M.E.; Loey, van A.

    2011-01-01

    The impact of thermal, high pressure (HP) and pulsed electric field (PEF) processing for mild pasteurization of orange juice was compared on a fair basis, using processing conditions leading to an equivalent degree of microbial inactivation. Examining the effect on specific chemical and biochemical

  17. Long-period amplification in deep alluvial basins and consequences for site-specific probabilistic seismic-hazard: the case of Castelleone in the Po Plain (Northern Italy)

    Science.gov (United States)

    Barani, S.; Mascandola, C.; Massa, M.; Spallarossa, D.

    2017-12-01

    The recent Emilia seismic sequence (Northern Italy) occurred at the end of the first half of 2012 with main shock of Mw6.1 highlighted the importance of studying site effects in the Po Plain, the larger and deeper sedimentary basin in Italy. As has long been known, long-period amplification related to deep sedimentary basins can significantly affect the characteristics of the ground-motion induced by strong earthquakes. It follows that the effects of deep sedimentary deposits on ground shaking require special attention during the definition of the design seismic action. The work presented here analyzes the impact of deep-soil discontinuities on ground-motion amplification, with particular focus on long-period probabilistic seismic-hazard assessment. The study focuses on the site of Castelleone, where a seismic station of the Italian National Seismic Network has been recording since 2009. Our study includes both experimental and numerical site response analyses. Specifically, extensive active and passive geophysical measurements were carried out in order to define a detailed shear-wave velocity (VS) model to be used in the numerical analyses. These latter are needed to assess the site-specific ground-motion hazard. Besides classical seismic refraction profiles and multichannel analysis of surface waves, we analyzed ambient vibration measurements in both single and array configurations. The VS profile was determined via joint inversion of the experimental phase-velocity dispersion curve with the ellipticity curve derived from horizontal-to-vertical spectral ratios. The profile shows two main discontinuities at depths of around 160 and 1350 m, respectively. The probabilistic site-specific hazard was assessed in terms of both spectral acceleration and displacement. A partially non-ergodic approach was adopted. We have found that the spectral acceleration hazard is barely sensitive to long-period (up to 10 s) amplification related to the deeper discontinuity whereas the

  18. Daily maternal separations during stress hyporesponsive period decrease the thresholds of panic-like behaviors to electrical stimulation of the dorsal periaqueductal gray of the adult rat.

    Science.gov (United States)

    Borges-Aguiar, Ana Cristina; Schauffer, Luana Zanoni; de Kloet, Edo Ronald; Schenberg, Luiz Carlos

    2018-05-15

    The present study examined whether early life maternal separation (MS), a model of childhood separation anxiety, predisposes to panic at adulthood. For this purpose, male pups were submitted to 3-h daily maternal separations along postnatal (PN) days of either the 'stress hyporesponsive period' (SHRP) from PN4 to PN14 (MS11) or throughout lactation from PN2 to PN21 (MS20). Pups were further reunited to conscious (CM) or anesthetized (AM) mothers to assess the effect of mother-pup interaction upon reunion. Controls were subjected to brief handling (15 s) once a day throughout lactation (BH20). As adults (PN60), rats were tested for the thresholds to evoke panic-like behaviors upon electrical stimulation of dorsal periaqueductal gray matter and exposed to an elevated plus-maze, an open-field, a forced swim and a sucrose preference test. A factor analysis was also performed to gain insight into the meaning of behavioral tests. MS11-CM rather than MS20-CM rats showed enhanced panic responses and reductions in both swimming and sucrose preference. Panic facilitations were less intense in mother-neglected rats. Although MS did not affect anxiety, MS11-AM showed robust reductions of defecation in an open-field. Factor analysis singled out anxiety, hedonia, exploration, coping and gut activity. Although sucrose preference and coping loaded on separate factors, appetite (adult weight) correlated with active coping in both forced swim and open-field (central area exploration). Concluding, whereas 3h-daily maternal separations during SHRP increased rat's susceptibility to experimental panic attacks, separations throughout lactation had no effects on panic and enhanced active coping. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Improving arm function in chronic stroke: a pilot study of sensory amplitude electrical stimulation via glove electrode during task-specific training.

    Science.gov (United States)

    Sullivan, Jane; Girardi, Madeline; Hensley, Melissa; Rohaus, Jordan; Schewe, Clay; Whittey, Colby; Hansen, Piper; Muir, Kimberly

    2015-06-01

    To investigate the effects of sensory amplitude electrical stimulation (SES) delivered by glove electrode during task-specific exercise on arm movement, function, and sensation in chronic stroke. The design was an intervention pilot study, pre-test, post-test, follow-up design. The settings used were a university research laboratory and home-based intervention. Participants comprised of 11 individuals with chronic stroke (7.2 ± 4.1 years post onset) and moderate arm paresis, 10.82/20 ± 2.27 on the Stroke Rehabilitation Assessment of Movement (STREAM) - Arm Subscale. Participants were seven males and four females (mean age: 59 years). Participants were recruited from university-based database. Intervention- Participants engaged in task-specific training at home for 30 min, twice daily, for 5 weeks, while receiving SES via glove electrode. Participants received supervised task practice at least twice during intervention period for 1 hour. Main outcome measures- Jebsen-Taylor Hand Function Test (JTHFT), STREAM - Arm Subscale, Motor Activity Log-14 (MAL-14) - Amount and Quality Subscales, and Nottingham Stereognosis Assessment (NSA). Significant changes were found in group mean pre- and post-test comparisons on the NSA (P = 0.042), MAL amount subscale (P = 0.047), and JTHFT (with writing item 29 excluded) (P = 0.003) and in pre-test to follow-up comparisons on NSA (P = 0.027) and JTHFT (writing item excluded) (P = 0.009). There was no significant change on the STREAM (P = 1.0). Individuals with a greater baseline motor capacity determined by STREAM scores (P = 0.048) and more recent stroke (P = 0.014) had significantly greater improvements. Combining task-specific training with glove-based SES in chronic stroke resulted in changes in arm sensation and function that were maintained at 3-month follow-up.

  20. Plant growth stage-specific injury and economic injury level for verde plant bug, Creontiades signatus (Hemiptera: Miridae), on cotton: effect of bloom period of infestation.

    Science.gov (United States)

    Brewer, Michael J; Anderson, Darwin J; Armstrong, J Scott

    2013-10-01

    Verde plant bugs, Creontiades signatus Distant (Hemiptera: Miridae), were released onto caged cotton, Cossypium hirsutum L., for a 1-wk period to characterize the effects of insect density and bloom period of infestation on cotton injury and yield in 2011 and 2012, Corpus Christi, TX. When plants were infested during early bloom (10-11 nodes above first white flower), a linear decline in fruit retention and boll load and a linear increase in boll injury were detected as verde plant bug infestation levels increased from an average of 0.5 to 4 bugs per plant. Lint and seed yield per plant showed a corresponding decline. Fruit retention, boll load, and yield were not affected on plants infested 1 wk later at peak bloom (8-9 nodes above first white flower), even though boll injury increased as infestation levels increased. Second-year testing verified boll injury but not yield loss, when infestations occurred at peak bloom. Incidence of cotton boll rot, known to be associated with verde plant bug feeding, was low to modest (verde plant bug were important contributors to yield decline, damage potential was greatest during the early bloom period of infestation, and a simple linear response best described the yield response-insect density relationship at early bloom. Confirmation that cotton after peak bloom was less prone to verde plant bug injury and an early bloom-specific economic injury level were key findings that can improve integrated pest management decision-making for dryland cotton, at least under low-rainfall growing conditions.

  1. Codes in the codons: construction of a codon/amino acid periodic table and a study of the nature of specific nucleic acid-protein interactions.

    Science.gov (United States)

    Benyo, B; Biro, J C; Benyo, Z

    2004-01-01

    The theory of "codon-amino acid coevolution" was first proposed by Woese in 1967. It suggests that there is a stereochemical matching - that is, affinity - between amino acids and certain of the base triplet sequences that code for those amino acids. We have constructed a common periodic table of codons and amino acids, where the nucleic acid table showed perfect axial symmetry for codons and the corresponding amino acid table also displayed periodicity regarding the biochemical properties (charge and hydrophobicity) of the 20 amino acids and the position of the stop signals. The table indicates that the middle (2/sup nd/) amino acid in the codon has a prominent role in determining some of the structural features of the amino acids. The possibility that physical contact between codons and amino acids might exist was tested on restriction enzymes. Many recognition site-like sequences were found in the coding sequences of these enzymes and as many as 73 examples of codon-amino acid co-location were observed in the 7 known 3D structures (December 2003) of endonuclease-nucleic acid complexes. These results indicate that the smallest possible units of specific nucleic acid-protein interaction are indeed the stereochemically compatible codons and amino acids.

  2. Influence of social networks on latent choice of electric cars : a mixed logit specification using experimental design data

    NARCIS (Netherlands)

    Rasouli, S.; Timmermans, H.J.P.

    2016-01-01

    Electric cars can potentially make a substantial contribution to the reduction of pollution and noise. The size of this contribution depends on the acceptance of this new technology in the market. This paper reports on the design and results of an elaborate stated choice experiment to investigate

  3. Specific properties of the electrical equipment in the nuclear steam supply system; Specificnosti elektricne opreme u primarnom djelu nuklearne elektrane

    Energy Technology Data Exchange (ETDEWEB)

    Smiljanic, D [Rade Koncar Institut, Zagreb (Yugoslavia)

    1979-07-01

    The paper presents description of reactor coolant pump motor in the primary coolant loop. The motor is treated as a representative of all electrical equipment in the nuclear steam supply system that has to meet all the requirements concerning reliability, minimum maintenance, radiation, seismic etc. (author)

  4. Evaluation of passive avoidance learning and spatial memory in rats exposed to low levels of lead during specific periods of early brain development.

    Science.gov (United States)

    Rao Barkur, Rajashekar; Bairy, Laxminarayana K

    2015-01-01

    Widespread use of heavy metal lead (Pb) for various commercial purposes has resulted in the environmental contamination caused by this metal. The studies have shown a definite relationship between low level lead exposure during early brain development and deficit in children's cognitive functions. This study investigated the passive avoidance learning and spatial learning in male rat pups exposed to lead through their mothers during specific periods of early brain development. Experimental male rats were divided into 5 groups: i) the normal control group (NC) (N = 12) consisted of rat offspring born to mothers who were given normal drinking water throughout gestation and lactation, ii) the pre-gestation lead exposed group (PG) (N = 12) consisted of rat offspring, mothers of these rats had been exposed to 0.2% lead acetate in the drinking water for 1 month before conception, iii) the gestation lead exposed group (G) (N = 12) contained rat offspring born to mothers who had been exposed to 0.2% lead acetate in the drinking water throughout gestation, iv) the lactation lead exposed group (L) (N = 12) had rat offspring, mothers of these rats exposed to 0.2% lead acetate in the drinking water throughout lactation and v) the gestation and lactation lead exposed group (GL) (N = 12) contained rat offspring, mothers of these rats were exposed to 0.2% lead acetate throughout gestation and lactation. The study found deficit in passive avoidance learning in the G, L and GL groups of rats. Impairment in spatial learning was found in the PG, G, L and GL groups of rats. Interestingly, the study found that gestation period only and lactation period only lead exposure was sufficient to cause deficit in learning and memory in rats. The extent of memory impairment in the L group of rats was comparable with the GL group of rats. So it can be said that postnatal period of brain development is more sensitive to neurotoxicity compared to prenatal exposure. This work is available in Open

  5. CRISP. Functional Specifications of electric Networks with high degrees of distributed generation. Deliverable D1.1

    International Nuclear Information System (INIS)

    Fontela, M.; Bacha, S.; Hadsjaid, N.; Andrieu, C.

    2007-09-01

    The deliverable D 1.1 is the first step in the project. This D 1.1 deliverable treats the different components: networks, generation sources and also the actors present in the energy market. The French system is usually commented but comments about the other countries uses are also mentioned. Special attention has been paid to the Dutch system, and a comparison is made between the French and the Dutch system. The main goal of this work is to describe the electric system and its components. Also a benchmarking model is proposed in order to start the studies of the different work package. This benchmarking model implies: the transmission, sub-transmission and distribution electric sub-systems. From this model, different scenarios of perturbations are studied. These scenarios correspond to different framework times (transient and steady states) and they could become fatal for the system operation

  6. Analysis of in situ electric field and specific absorption rate in human models for wireless power transfer system with induction coupling

    International Nuclear Information System (INIS)

    Sunohara, Tetsu; Hirata, Akimasa; Laakso, Ilkka; Onishi, Teruo

    2014-01-01

    This study investigates the specific absorption rate (SAR) and the in situ electric field in anatomically based human models for the magnetic field from an inductive wireless power transfer system developed on the basis of the specifications of the wireless power consortium. The transfer system consists of two induction coils covered by magnetic sheets. Both the waiting and charging conditions are considered. The transfer frequency considered in this study is 140 kHz, which is within the range where the magneto-quasi-static approximation is valid. The SAR and in situ electric field in the chest and arm of the models are calculated by numerically solving the scalar potential finite difference equation. The electromagnetic modelling of the coils in the wireless power transfer system is verified by comparing the computed and measured magnetic field distributions. The results indicate that the peak value of the SAR averaged over a 10 g of tissue and that of the in situ electric field are 72 nW kg −1  and 91 mV m −1  for a transmitted power of 1 W, Consequently, the maximum allowable transmitted powers satisfying the exposure limits of the SAR (2 W kg −1 ) and the in situ electric field (18.9 V m −1 ) are found to be 28 MW and 43 kW. The computational results show that the in situ electric field in the chest is the most restrictive factor when compliance with the wireless power transfer system is evaluated according to international guidelines. (paper)

  7. Analysis of in situ electric field and specific absorption rate in human models for wireless power transfer system with induction coupling.

    Science.gov (United States)

    Sunohara, Tetsu; Hirata, Akimasa; Laakso, Ilkka; Onishi, Teruo

    2014-07-21

    This study investigates the specific absorption rate (SAR) and the in situ electric field in anatomically based human models for the magnetic field from an inductive wireless power transfer system developed on the basis of the specifications of the wireless power consortium. The transfer system consists of two induction coils covered by magnetic sheets. Both the waiting and charging conditions are considered. The transfer frequency considered in this study is 140 kHz, which is within the range where the magneto-quasi-static approximation is valid. The SAR and in situ electric field in the chest and arm of the models are calculated by numerically solving the scalar potential finite difference equation. The electromagnetic modelling of the coils in the wireless power transfer system is verified by comparing the computed and measured magnetic field distributions. The results indicate that the peak value of the SAR averaged over a 10 g of tissue and that of the in situ electric field are 72 nW kg(-1) and 91 mV m(-1) for a transmitted power of 1 W, Consequently, the maximum allowable transmitted powers satisfying the exposure limits of the SAR (2 W kg(-1)) and the in situ electric field (18.9 V m(-1)) are found to be 28 MW and 43 kW. The computational results show that the in situ electric field in the chest is the most restrictive factor when compliance with the wireless power transfer system is evaluated according to international guidelines.

  8. Working group 1: Economic aspects. Main financial and economic problems required by the development of electricity district area during the period 1976-1985

    International Nuclear Information System (INIS)

    Maldague, R.; Frerotte, M.

    1976-01-01

    From three different G.N.P. growth rates models for the country the consumption of primary energy and electricity in 1985 and afterwards is evaluated following four models. The compared MWh cost of nuclear and classical power stations for electricity production evaluated for 1985 are analysed. The assumed power is 1300 MW for the nuclear and 600 MW for the classical power station. The power stations to install afterwards 1985 are presented and their impact on the financial investments, the employment and trade balance is considered. (A.F.)

  9. Network, system, and status software enhancements for the autonomously managed electrical power system breadboard. Volume 3: Commands specification

    Science.gov (United States)

    Mckee, James W.

    1990-01-01

    This volume (3 of 4) contains the specification for the command language for the AMPS system. The volume contains a requirements specification for the operating system and commands and a design specification for the operating system and command. The operating system and commands sits on top of the protocol. The commands are an extension of the present set of AMPS commands in that the commands are more compact, allow multiple sub-commands to be bundled into one command, and have provisions for identifying the sender and the intended receiver. The commands make no change to the actual software that implement the commands.

  10. Determination of Specific Losses in the Limbs of an Epstein Frame Using a Three Epstein Frame Methodology Applied to Grain Oriented Electrical Steels.

    Science.gov (United States)

    Parent, Guillaume; Penin, Rémi; Lecointe, Jean-Philippe; Brudny, Jean-François; Belgrand, Thierry

    2016-06-04

    An experimental method to characterize the magnetic properties of Grain Oriented Electrical Steel in the rolling direction is proposed in this paper. It relies on the use of three 25 cm Epstein frames combined to generate three test-frames of different lengths. This enables the identification of the effective specific losses of the electrical steel when magnetization is applied along the rolling direction. As a consequence, it evidences the deviation of the loss figures obtained using the standardised Epstein test. The difference in losses is explained by the fact that the described method gives "only" the losses attached to the straight parts. The concept of the magnetic path length as defined by the standard is discussed.

  11. Determination of Specific Losses in the Limbs of an Epstein Frame Using a Three Epstein Frame Methodology Applied to Grain Oriented Electrical Steels

    Directory of Open Access Journals (Sweden)

    Guillaume Parent

    2016-06-01

    Full Text Available An experimental method to characterize the magnetic properties of Grain Oriented Electrical Steel in the rolling direction is proposed in this paper. It relies on the use of three 25 cm Epstein frames combined to generate three test-frames of different lengths. This enables the identification of the effective specific losses of the electrical steel when magnetization is applied along the rolling direction. As a consequence, it evidences the deviation of the loss figures obtained using the standardised Epstein test. The difference in losses is explained by the fact that the described method gives “only” the losses attached to the straight parts. The concept of the magnetic path length as defined by the standard is discussed.

  12. Wearable sensors for patient-specific boundary shape estimation to improve the forward model for electrical impedance tomography (EIT) of neonatal lung function.

    Science.gov (United States)

    Khor, Joo Moy; Tizzard, Andrew; Demosthenous, Andreas; Bayford, Richard

    2014-06-01

    Electrical impedance tomography (EIT) could be significantly advantageous to continuous monitoring of lung development in newborn and, in particular, preterm infants as it is non-invasive and safe to use within the intensive care unit. It has been demonstrated that accurate boundary form of the forward model is important to minimize artefacts in reconstructed electrical impedance images. This paper presents the outcomes of initial investigations for acquiring patient-specific thorax boundary information using a network of flexible sensors that imposes no restrictions on the patient's normal breathing and movements. The investigations include: (1) description of the basis of the reconstruction algorithms, (2) tests to determine a minimum number of bend sensors, (3) validation of two approaches to reconstruction and (4) an example of a commercially available bend sensor and its performance. Simulation results using ideal sensors show that, in the worst case, a total shape error of less than 6% with respect to its total perimeter can be achieved.

  13. Exposure to altered gravity during specific developmental periods differentially affects growth, development, the cerebellum and motor functions in male and female rats

    Science.gov (United States)

    Nguon, K.; Ladd, B.; Sajdel-Sulkowska, E. M.

    2006-01-01

    We previously reported that perinatal exposure to hypergravity affects cerebellar structure and motor coordination in rat neonates. In the present study, we explored the hypothesis that neonatal cerebellar structure and motor coordination may be particularly vulnerable to the effects of hypergravity during specific developmental stages. To test this hypothesis, we compared neurodevelopment, motor behavior and cerebellar structure in rat neonates exposed to 1.65 G on a 24-ft centrifuge during discrete periods of time: the 2nd week of pregnancy [gestational day (G) 8 through G15; group A], the 3rd week of pregnancy (G15 through birth on G22/G23; group B), the 1st week of nursing [birth through postnatal day (P) 6; group C], the 2nd and 3rd weeks of nursing (P6 through P21; group D), the combined 2nd and 3rd weeks of pregnancy and nursing (G8 through P21; group E) and stationary control (SC) neonates (group F). Prenatal exposure to hypergravity resulted in intrauterine growth retardation as reflected by a decrease in the number of pups in a litter and lower average mass at birth. Exposure to hypergravity immediately after birth impaired the righting response on P3, while the startle response in both males and females was most affected by exposure during the 2nd and 3rd weeks after birth. Hypergravity exposure also impaired motor functions, as evidenced by poorer performance on a rotarod; while both males and females exposed to hypergravity during the 2nd and 3rd weeks after birth performed poorly on P21, male neonates were most dramatically affected by exposure to hypergravity during the second week of gestation, when the duration of their recorded stay on the rotarod was one half that of SC males. Cerebellar mass was most reduced by later postnatal exposure. Thus, for the developing rat cerebellum, the postnatal period that overlaps the brain growth spurt is the most vulnerable to hypergravity. However, male motor behavior is also affected by midpregnancy exposure to

  14. Uneconomical tops of renewable electricity options. Advice with regard to the determination of the MEP subsidies for the period July up to and including December 2006 and 2007

    International Nuclear Information System (INIS)

    Van Sambeek, E.J.W.; De Vries, H.; Cleijne, J.W.; Pfeiffer, E.A.

    2004-11-01

    On assignment of the Dutch Ministry of Economic Affairs ECN and KEMA investigated the financial gaps of renewable electricity production technologies. These form the basis for determining the level of the MEP-subsidies (subsidy for the environmental quality of power generation) for different renewable electricity sources and technologies by the Ministry. This report contains an advice on the financial gaps that are to be used for determining the subsidy levels. The calculation of the financial gaps is based on an earlier report on the inputs for the calculations and on the subsequent stakeholder consultation with respect to these inputs. A detailed description is given of the assumptions, calculations and stakeholder inputs underlying the financial gaps for the establishment of the MEP-subsidies for new projects starting from July 2006 till December 2007 [nl

  15. Dynamics of Ring Current and Electric Fields in the Inner Magnetosphere During Disturbed Periods: CRCM-BATS-R-US Coupled Model

    Science.gov (United States)

    Buzulukova, N.; Fok, M.-C.; Pulkkinen, A.; Kuznetsova, M.; Moore, T. E.; Glocer, A.; Brandt, P. C.; Toth, G.; Rastaetter, L.

    2010-01-01

    We present simulation results from a one-way coupled global MHD model (Block-Adaptive-Tree Solar-Wind Roe-Type Upwind Scheme, BATS-R-US) and kinetic ring current models (Comprehensive Ring Current Model, CRCM, and Fok Ring Current, FokRC). The BATS-R-US provides the CRCM/FokRC with magnetic field information and plasma density/temperature at the polar CRCM/FokRC boundary. The CRCM uses an electric potential from the BATS-R-US ionospheric solver at the polar CRCM boundary in order to calculate the electric field pattern consistent with the CRCM pressure distribution. The FokRC electric field potential is taken from BATS-R-US ionospheric solver everywhere in the modeled region, and the effect of Region II currents is neglected. We show that for an idealized case with southward-northward-southward Bz IMF turning, CRCM-BATS-R-US reproduces well known features of inner magnetosphere electrodynamics: strong/weak convection under the southward/northward Bz; electric field shielding/overshielding/penetration effects; an injection during the substorm development; Subauroral Ion Drift or Polarization Jet (SAID/PJ) signature in the dusk sector. Furthermore, we find for the idealized case that SAID/PJ forms during the substorm growth phase, and that substorm injection has its own structure of field-aligned currents which resembles a substorm current wedge. For an actual event (12 August 2000 storm), we calculate ENA emissions and compare with Imager for Magnetopause-to-Aurora Global Exploration/High Energy Neutral Atom data. The CRCM-BATS-R-US reproduces both the global morphology of ring current and the fine structure of ring current injection. The FokRC-BATS-R-US shows the effect of a realistic description of Region II currents in ring current-MHD coupled models.

  16. A specific and correlative study of natural atmospheric radioactivity, condensation nuclei and some electrical parameters in marine or urban sites

    International Nuclear Information System (INIS)

    Le Gac, Jacqueline.

    1980-02-01

    In order to determine the correlations between the following atmospheric parameters: radon and condensation nuclei concentrations, total conductivity and space charge, we analysed their behavior over a long period, in connection with meteorological data. We simulaneously studied the equilibrium state between 222 Rn and its short-lived daughters pointing out a radioactive desequilibrium as a function of the meteorological conditions. Simultaneously, we established average experimental curves of cumulated particle size distributions of natural radioactivity in the air, differentiating urban and marine influences. Finally, a comparison between the various parameters showed that the total conductivity greatly depends on condensation nuclei and radon concentrations in the air [fr

  17. Risk perception and strategic decision making :general insights, a framework, and specific application to electricity generation using nuclear energy

    International Nuclear Information System (INIS)

    Brewer, Jeffrey D.

    2005-01-01

    The objective of this report is to promote increased understanding of decision making processes and hopefully to enable improved decision making regarding high-consequence, highly sophisticated technological systems. This report brings together insights regarding risk perception and decision making across domains ranging from nuclear power technology safety, cognitive psychology, economics, science education, public policy, and neural science (to name a few). It forms them into a unique, coherent, concise framework, and list of strategies to aid in decision making. It is suggested that all decision makers, whether ordinary citizens, academics, or political leaders, ought to cultivate their abilities to separate the wheat from the chaff in these types of decision making instances. The wheat includes proper data sources and helpful human decision making heuristics; these should be sought. The chaff includes ''unhelpful biases'' that hinder proper interpretation of available data and lead people unwittingly toward inappropriate decision making ''strategies''; obviously, these should be avoided. It is further proposed that successfully accomplishing the wheat vs. chaff separation is very difficult, yet tenable. This report hopes to expose and facilitate navigation away from decision-making traps which often ensnare the unwary. Furthermore, it is emphasized that one's personal decision making biases can be examined, and tools can be provided allowing better means to generate, evaluate, and select among decision options. Many examples in this report are tailored to the energy domain (esp. nuclear power for electricity generation). The decision making framework and approach presented here are applicable to any high-consequence, highly sophisticated technological system

  18. In-place measurement of specific electric resistance during precipitation of γ'-precipitating Ni base alloys

    International Nuclear Information System (INIS)

    Silomon, M.

    1991-01-01

    During precipitation and coarsening of a second phase, the electric resistance of an alloy changes. Continuous resistance measurement is possible during heat treatment and can be conducted with limited experimental effort; any metallographic determination of the temperature and time dependencies of structural changes, however, requires very high effort. For this reason, an instrument was set up which permits continuous measurement of the resistance at precipitation temperature and during heating or cooling, while providing sufficient resolution for minor changes. Both measuring methods are conducted on technologically relevant alloys such as Nimonic PE 16 and those based on Ni-20 At.% Cr with deliberately varied additions of Al and Ti (accompanying investigations: TEM, SANS, and calorimetry). Their usefulness for alloy development is discussed within the scope of current concepts of demixing kinetics and resistance of alloys. Essential results concern the matrix/γ'-phase mismatch, the Ni 2 Cr short range order, and determination of the γ'-solvus temperature. (orig.) With 53 figs., 4 tabs [de

  19. Ice storage facilities may use excess contingents of electricity. Reduction of the payback period by smart grids; Eisspeicher koennen ueberschuessige Stromkontingente nutzen. Amortisationszeit durch Smart Grid verkuerzen

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Klaus [Fafco S.A., Biel (Switzerland); Schmid, Wolfgang

    2013-03-11

    In Germany, energy storage device attain a great importance in the energy supply. However, up to now economical technologies are missing in order to store fluctuating offers of electricity from renewable energy sources directly in a storage medium. Within the modern refrigeration and air conditioning, ice storage facilities proved over decades could take up this position and could be one component of the energy policy turnaround. New tariff offers as well as the construction of virtual power plants let expect that ice storage facilities may amortize within few years.

  20. Periodically pulsed wet annealing approach for low-temperature processable amorphous InGaZnO thin film transistors with high electrical performance and ultrathin thickness

    OpenAIRE

    Kim, Ye Kyun; Ahn, Cheol Hyoun; Yun, Myeong Gu; Cho, Sung Woon; Kang, Won Jun; Cho, Hyung Koun

    2016-01-01

    In this paper, a simple and controllable ?wet pulse annealing? technique for the fabrication of flexible amorphous InGaZnO thin film transistors (a-IGZO TFTs) processed at low temperature (150??C) by using scalable vacuum deposition is proposed. This method entailed the quick injection of water vapor for 0.1?s and purge treatment in dry ambient in one cycle; the supply content of water vapor was simply controlled by the number of pulse repetitions. The electrical transport characteristics rev...

  1. Risk perception & strategic decision making :general insights, a framework, and specific application to electricity generation using nuclear energy.

    Energy Technology Data Exchange (ETDEWEB)

    Brewer, Jeffrey D.

    2005-11-01

    The objective of this report is to promote increased understanding of decision making processes and hopefully to enable improved decision making regarding high-consequence, highly sophisticated technological systems. This report brings together insights regarding risk perception and decision making across domains ranging from nuclear power technology safety, cognitive psychology, economics, science education, public policy, and neural science (to name a few). It forms them into a unique, coherent, concise framework, and list of strategies to aid in decision making. It is suggested that all decision makers, whether ordinary citizens, academics, or political leaders, ought to cultivate their abilities to separate the wheat from the chaff in these types of decision making instances. The wheat includes proper data sources and helpful human decision making heuristics; these should be sought. The chaff includes ''unhelpful biases'' that hinder proper interpretation of available data and lead people unwittingly toward inappropriate decision making ''strategies''; obviously, these should be avoided. It is further proposed that successfully accomplishing the wheat vs. chaff separation is very difficult, yet tenable. This report hopes to expose and facilitate navigation away from decision-making traps which often ensnare the unwary. Furthermore, it is emphasized that one's personal decision making biases can be examined, and tools can be provided allowing better means to generate, evaluate, and select among decision options. Many examples in this report are tailored to the energy domain (esp. nuclear power for electricity generation). The decision making framework and approach presented here are applicable to any high-consequence, highly sophisticated technological system.

  2. Periodically pulsed wet annealing approach for low-temperature processable amorphous InGaZnO thin film transistors with high electrical performance and ultrathin thickness.

    Science.gov (United States)

    Kim, Ye Kyun; Ahn, Cheol Hyoun; Yun, Myeong Gu; Cho, Sung Woon; Kang, Won Jun; Cho, Hyung Koun

    2016-05-20

    In this paper, a simple and controllable "wet pulse annealing" technique for the fabrication of flexible amorphous InGaZnO thin film transistors (a-IGZO TFTs) processed at low temperature (150 °C) by using scalable vacuum deposition is proposed. This method entailed the quick injection of water vapor for 0.1 s and purge treatment in dry ambient in one cycle; the supply content of water vapor was simply controlled by the number of pulse repetitions. The electrical transport characteristics revealed a remarkable performance of the a-IGZO TFTs prepared at the maximum process temperature of 150 °C (field-effect mobility of 13.3 cm(2) V(-1) s(-1); Ion/Ioff ratio ≈ 10(8); reduced I-V hysteresis), comparable to that of a-IGZO TFTs annealed at 350 °C in dry ambient. Upon analysis of the angle-resolved x-ray photoelectron spectroscopy, the good performance was attributed to the effective suppression of the formation of hydroxide and oxygen-related defects. Finally, by using the wet pulse annealing process, we fabricated, on a plastic substrate, an ultrathin flexible a-IGZO TFT with good electrical and bending performances.

  3. Periodically pulsed wet annealing approach for low-temperature processable amorphous InGaZnO thin film transistors with high electrical performance and ultrathin thickness

    Science.gov (United States)

    Kim, Ye Kyun; Ahn, Cheol Hyoun; Yun, Myeong Gu; Cho, Sung Woon; Kang, Won Jun; Cho, Hyung Koun

    2016-01-01

    In this paper, a simple and controllable “wet pulse annealing” technique for the fabrication of flexible amorphous InGaZnO thin film transistors (a-IGZO TFTs) processed at low temperature (150 °C) by using scalable vacuum deposition is proposed. This method entailed the quick injection of water vapor for 0.1 s and purge treatment in dry ambient in one cycle; the supply content of water vapor was simply controlled by the number of pulse repetitions. The electrical transport characteristics revealed a remarkable performance of the a-IGZO TFTs prepared at the maximum process temperature of 150 °C (field-effect mobility of 13.3 cm2 V−1 s−1; Ion/Ioff ratio ≈ 108; reduced I-V hysteresis), comparable to that of a-IGZO TFTs annealed at 350 °C in dry ambient. Upon analysis of the angle-resolved x-ray photoelectron spectroscopy, the good performance was attributed to the effective suppression of the formation of hydroxide and oxygen-related defects. Finally, by using the wet pulse annealing process, we fabricated, on a plastic substrate, an ultrathin flexible a-IGZO TFT with good electrical and bending performances. PMID:27198067

  4. Estimating State-Specific Contributions to PM2.5- and O3-Related Health Burden from Residential Combustion and Electricity Generating Unit Emissions in the United States.

    Science.gov (United States)

    Penn, Stefani L; Arunachalam, Saravanan; Woody, Matthew; Heiger-Bernays, Wendy; Tripodis, Yorghos; Levy, Jonathan I

    2017-03-01

    Residential combustion (RC) and electricity generating unit (EGU) emissions adversely impact air quality and human health by increasing ambient concentrations of fine particulate matter (PM 2.5 ) and ozone (O 3 ). Studies to date have not isolated contributing emissions by state of origin (source-state), which is necessary for policy makers to determine efficient strategies to decrease health impacts. In this study, we aimed to estimate health impacts (premature mortalities) attributable to PM 2.5 and O 3 from RC and EGU emissions by precursor species, source sector, and source-state in the continental United States for 2005. We used the Community Multiscale Air Quality model employing the decoupled direct method to quantify changes in air quality and epidemiological evidence to determine concentration-response functions to calculate associated health impacts. We estimated 21,000 premature mortalities per year from EGU emissions, driven by sulfur dioxide emissions forming PM 2.5 . More than half of EGU health impacts are attributable to emissions from eight states with significant coal combustion and large downwind populations. We estimate 10,000 premature mortalities per year from RC emissions, driven by primary PM 2.5 emissions. States with large populations and significant residential wood combustion dominate RC health impacts. Annual mortality risk per thousand tons of precursor emissions (health damage functions) varied significantly across source-states for both source sectors and all precursor pollutants. Our findings reinforce the importance of pollutant-specific, location-specific, and source-specific models of health impacts in design of health-risk minimizing emissions control policies. Citation: Penn SL, Arunachalam S, Woody M, Heiger-Bernays W, Tripodis Y, Levy JI. 2017. Estimating state-specific contributions to PM 2.5 - and O 3 -related health burden from residential combustion and electricity generating unit emissions in the United States. Environ

  5. Proposal planning of expansion of electric power generating facilities of Rio Grande do Sul in 2008-2030 period; Proposta de planejamento de expansao do parque gerador de energia eletrica do Rio Grande do Sul no periodo 2008-2030

    Energy Technology Data Exchange (ETDEWEB)

    Magayevski, Juliano; Santos, Joao Carlos Vernetti dos [Universidade Luterana do Brasil (PPGEAM/ULBRA), Gravatai, RS (Brazil). Programa de Pos-Graduacao em Engenharia, Energia, Ambiente e Materiais

    2010-07-01

    This work examines the indicators of wealth and its relations with the electricity demand for the State of Rio Grande do Sul, with a trend scenario and alternative scenarios for the electricity demand for the period 2008-2030. A capacity model was developed in order to estimate the increase of the installed capacity necessary to supply the foreseen demand. This model considers new additions of the power plants in implantation, planned and in study, from a base of information and data of the Ministry of Energy. Based on the comparison of the scenarios established with the developed model, are identified strangulations of power supply in the considered time for two of them, the participation of the primary sources capable to prevent them is explored and the total investment for realization of developed model and one established scenario that show strangulation, through hydroelectric plants, thermoelectric based on mineral coal and thermoelectric based on natural gas. (author)

  6. Network, system, and status software enhancements for the autonomously managed electrical power system breadboard. Volume 2: Protocol specification

    Science.gov (United States)

    Mckee, James W.

    1990-01-01

    This volume (2 of 4) contains the specification, structured flow charts, and code listing for the protocol. The purpose of an autonomous power system on a spacecraft is to relieve humans from having to continuously monitor and control the generation, storage, and distribution of power in the craft. This implies that algorithms will have been developed to monitor and control the power system. The power system will contain computers on which the algorithms run. There should be one control computer system that makes the high level decisions and sends commands to and receive data from the other distributed computers. This will require a communications network and an efficient protocol by which the computers will communicate. One of the major requirements on the protocol is that it be real time because of the need to control the power elements.

  7. Wire Probe Antenna (WPT) and Electric Field Detector (EFD) of Plasma Wave Experiment (PWE) aboard the Arase satellite: specifications and initial evaluation results

    Science.gov (United States)

    Kasaba, Yasumasa; Ishisaka, Keigo; Kasahara, Yoshiya; Imachi, Tomohiko; Yagitani, Satoshi; Kojima, Hirotsugu; Matsuda, Shoya; Shoji, Masafumi; Kurita, Satoshi; Hori, Tomoaki; Shinbori, Atsuki; Teramoto, Mariko; Miyoshi, Yoshizumi; Nakagawa, Tomoko; Takahashi, Naoko; Nishimura, Yukitoshi; Matsuoka, Ayako; Kumamoto, Atsushi; Tsuchiya, Fuminori; Nomura, Reiko

    2017-12-01

    This paper summarizes the specifications and initial evaluation results of Wire Probe Antenna (WPT) and Electric Field Detector (EFD), the key components for the electric field measurement of the Plasma Wave Experiment (PWE) aboard the Arase (ERG) satellite. WPT consists of two pairs of dipole antennas with 31-m tip-to-tip length. Each antenna element has a spherical probe (60 mm diameter) at each end of the wire (15 m length). They are extended orthogonally in the spin plane of the spacecraft, which is roughly perpendicular to the Sun and enables to measure the electric field in the frequency range of DC to 10 MHz. This system is almost identical to the WPT of Plasma Wave Investigation aboard the BepiColombo Mercury Magnetospheric Orbiter, except for the material of the spherical probe (ERG: Al alloy, MMO: Ti alloy). EFD is a part of the EWO (EFD/WFC/OFA) receiver and measures the 2-ch electric field at a sampling rate of 512 Hz (dynamic range: ± 200 mV/m) and the 4-ch spacecraft potential at a sampling rate of 128 Hz (dynamic range: ± 100 V and ± 3 V/m), with the bias control capability of WPT. The electric field waveform provides (1) fundamental information about the plasma dynamics and accelerations and (2) the characteristics of MHD and ion waves in various magnetospheric statuses with the magnetic field measured by MGF and PWE-MSC. The spacecraft potential provides information on thermal electron plasma variations and structure combined with the electron density obtained from the upper hybrid resonance frequency provided by PWE-HFA. EFD has two data modes. The continuous (medium-mode) data are provided as (1) 2-ch waveforms at 64 Hz (in apoapsis mode, L > 4) or 256 Hz (in periapsis mode, L < 4), (2) 1-ch spectrum within 1-232 Hz with 1-s resolution, and (3) 4-ch spacecraft potential at 8 Hz. The burst (high-mode) data are intermittently obtained as (4) 2-ch waveforms at 512 Hz and (5) 4-ch spacecraft potential at 128 Hz and downloaded with the WFC

  8. Wire Probe Antenna (WPT) and Electric Field Detector (EFD0 of Plasma Wave Experiment (PWE) aboard ARASE: Specifications and Evaluation results

    Science.gov (United States)

    Matsuda, S.; Kasaba, Y.; Ishisaka, K.; Kasahara, Y.; Imachi, T.; Yagitani, S.; Kojima, H.; Kurita, S.; Shoji, M.; Hori, T.; Shinbori, A.; Teramoto, M.; Miyoshi, Y.; Nakagawa, T.; Takahashi, N.; Nishimura, Y.; Matsuoka, A.; Tsuchiya, F.; Kumamoto, A.; Nomura, R.

    2017-12-01

    This paper summarizes the specifications and the evaluation results of Wire Probe Antenna (WPT) and Electric Field Detector (EFD), which are the key parts of Plasma Wave Experiment (PWE) aboard the Arase satellite, in their initial operations and the beginning phase of the full observations. WPT consists of the two dipole antennas as electric field sensors with 32m tip-to-tip length, with a sphere probe (6 cm diameter) attached at each end of wires (length: 15-m). They are extended orthogonally in the spin plane which is roughly perpendicular to the Sun. It enables the PWE to measure the E-field from DC to 10 MHz. This system is almost compatible to the WPT of the Plasma Wave Investigation (PWI) aboard BepiColombo Mercury Magnetospheric Orbiter, except the material of the spherical probe (ERG: Aluminium alloy, MMO: Titanium-alloy). This paper shows the extended length evaluated by the Lorentz force (spacecraft velocity x B-field) and the antenna impedance as the basic information of the E-field measurement capability of the PWE E-field receivers, with the evaluation for the possible degradation of the probe surface coated by TiAlN as BepiColombo. EFD is the 2-channel low frequency electric receiver as a part of EWO (EFD/WFC/OFA), for the measurement of 2ch electric field in the spin-plane with the sampling rate of 512 Hz (dynamic range: +-200 mV/m, +-3 V/m) and the 4ch spacecraft potential with the sampling rate of 128 Hz (dynamic range: +-100 V), respectively, with the bias control capability fed to the WPT probes. The electric field in DC - 232Hz provides the capability to detect (1) the fundamental information of the plasma dynamics and accelerations and (2) the characteristics of MHD and ion waves with their Poynting vectors with the data measured by MGF and PWE/WFC-B connected to PWE/SCM. The spacecraft potential provides the electron density information with UHR frequency. This paper also introduces the data sets and their calibration status.

  9. Mortality in nuclear workers of the French electricity company: period 1968-2003; Cohorte des travailleurs du nucleaire a Electricite de France: mortalite des agents statutaires sur la periode 1968-2003

    Energy Technology Data Exchange (ETDEWEB)

    Rogel, A.; Joly, K.; Metz-Flamant, C.; Laurent, O.; Tirmarche, M.; Laurier, D. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Lab. d' Epidemiologie, DRPH/SRBE/LEPID, 92 - Fontenay-aux-roses (France); Hubert, D.; Garcier, Y. [Electricite de France (EDF), 93 - Saint-Denis (France)

    2009-08-15

    Background We conducted a mortality study on a cohort of French nuclear workers employed at Electricite de France (EDF). A first cancer mortality analysis had covered the period 1968-1994. This paper presents results from a mortality analysis including nine additional years of follow-up to cover workers employed from 1968 to 2003. Methods The cohort includes 22 393 workers, 97% of whom are males. Employment data were updated using the EDF personnel file. Vital status was ascertained using the French National Registry of Population, and further completed using EDF personnel and pension files. Causes of death were obtained from the National registry of causes of death. Standardised Mortality Ratios (S.M.R.) were computed using national rates as references. Variations of all causes and all cancers S.M.R.s were studied according to demographic and occupational characteristics. Results At the study end point (31/12/2003), 74% of workers are still in active employment. Only 0.3% of workers are lost to follow-up. The median duration of follow-up is 20 years. Causes are ascertained for 96% of deaths. The total number of deaths is 874, 307 of which are cancer deaths. S.M.R.s for all causes and cancers show a significant deficit compared to the French national mortality. No significant excess was observed for any of the cancer sites studied. Non-significant excesses are observed for pancreatic, pleural, kidney and brain cancer. Significant variations of all causes S.M.R.s according to age at study entry and attained age are observed. Significant variations of all causes and all cancers S.M.R.s according to diploma at employment are observed, with a reduced S.M.R. for a higher level of diploma. Conclusion There is a significant deficit of mortality compared to the general population, reflecting a strong Healthy Worker Effect. Although nine years of follow-up were added, this cohort is made up of young workers, most of whom are still in active service. Regular updating of the

  10. Procedural Issues regarding the Audit of the Management and Control of EU Funds, in Terms of Specific Key Requirements of the New Funding Period 2014 - 2020

    Directory of Open Access Journals (Sweden)

    Stelian Selișteanu

    2016-11-01

    Full Text Available In practice, planning the audit of management and control for each operational program and for the whole programming period, will perform during substantiation audit strategy, based on analysis and risk assessment, made at the entities involved in implementing the operational program. In what follows, we propose an assessment guidelines for the 2014- 2020 programming period, especially in terms of explanation addressed key requirements that must be used, explaining the evaluation criteria for each key requirement, providing guidance for drawing conclusions for each key requirement by each authority and finally making recommendations for establishing general conclusions regarding the management and control.

  11. Thermal degradation characteristics and products obtained after pyrolysis of specific polymers found in Waste Electrical and Electronic Equipment

    Institute of Scientific and Technical Information of China (English)

    Evangelia C.Vouvoudi; Aristea T.Rousi; Dimitris S.Achilias

    2017-01-01

    Modern societies strongly support the recycling practices over simple waste accumulation due to environmental harm caused.In the framework of sustainable recycling of plastics from WEEE,pyrolysis is proposed here as a means of obtaining secondary value-added products.The aim of this study was to investigate the thermal degradation and the products obtained after pyrolysis of specific polymers found in the plastic part of WEEE,using thermogravimetric analysis and a pyrolizer equipped with a GC/MS.Polymers studied include ABS,HIPS,PC and a blend having a composition similar to that appearing in WEEE.It was found that,PC shows greater heat endurance compared to the other polymers,whereas ABS depolymerizes in three-steps.The existence of several polymers in the blend results in synergistic effects which decrease the onset and final temperature of degradation.Moreover,the fragmentation occurred in the pyrolyzer,at certain temperatures,resulted in a great variety of compounds,depending on the polymer type,such as monomers,aromatic products,phenolic compounds and hydrocarbons.The main conclusion from this investigation is that pyrolysis could be an effective method for the sustainable recycling of the plastic part of WEEE resulting in a mixture of chemicals with varying composition but being excellent to be used as fuel retrieved from secondary recycling sources.

  12. Reduced electric-octupole transition probabilities, B(E3;O1+ → 31-), for even-even nuclides throughout the periodic table

    International Nuclear Information System (INIS)

    Spear, R.H.

    1988-11-01

    Adopted values for the excitation energy, E x( 3 1 - ), of the first 3 - state of the even-even nuclei are tabulated. Values of the reduced electric-octupole transition probability, B(E3;O 1 + → 3 1 - ), from the ground state to this state, as determined from Coulomb excitation, lifetime measurements, inelastic electron scattering, deformation parameters β 3 obtained from angular distributions of inelastically scattered nucleons and light ions, and other miscellaneous procedures are listed in separate Tables. Adopted values for B(E3; O 1 + → 3 1 - ) are presented in Table VII, together with the E3 transition strengths, in Weisskopf units, and the product E x( 3 1 - ) x B(E3; O 1 + → 3 1 - - ) expressed as a percentage of the energy-weighted E3 sum-rule strength. An evaluation is made of the reliability of B(E3; O 1 + → 3 1 - ) values deduced from deformation parameters β 3 . The literature has been covered to March 1988

  13. Analysis of specific absorption rate and internal electric field in human biological tissues surrounding an air-core coil-type transcutaneous energy transmission transformer.

    Science.gov (United States)

    Shiba, Kenji; Zulkifli, Nur Elina Binti; Ishioka, Yuji

    2017-06-01

    In this study, we analyzed the internal electric field E and specific absorption rate (SAR) of human biological tissues surrounding an air-core coil transcutaneous energy transmission transformer. Using an electromagnetic simulator, we created a model of human biological tissues consisting of a dry skin, wet skin, fat, muscle, and cortical bone. A primary coil was placed on the surface of the skin, and a secondary coil was located subcutaneously inside the body. The E and SAR values for the model representing a 34-year-old male subject were analyzed using electrical frequencies of 0.3-1.5 MHz. The transmitting power was 15 W, and the load resistance was 38.4 Ω. The results showed that the E values were below the International Commission on Non-ionizing Radiation Protection (ICNIRP) limit for the general public exposure between the frequencies of 0.9 and 1.5 MHz, and SAR values were well below the limit prescribed by the ICNIRP for the general public exposure between the frequencies of 0.3 and 1.2 MHz.

  14. Electricity Storage. Technology Brief

    Energy Technology Data Exchange (ETDEWEB)

    Simbolotti, G. [Italian National Agency for New Technologies, Energy and Sustainable Economic Development ENEA, Rome (Italy); Kempener, R. [International Renewable Energy Agency IRENA, Bonn (Germany)

    2012-04-15

    Electricity storage is a key technology for electricity systems with a high share of renewables as it allows electricity to be generated when renewable sources (i.e. wind, sunlight) are available and to be consumed on demand. It is expected that the increasing price of fossil fuels and peak-load electricity and the growing share of renewables will result in electricity storage to grow rapidly and become more cost effective. However, electricity storage is technically challenging because electricity can only be stored after conversion into other forms of energy, and this involves expensive equipment and energy losses. At present, the only commercial storage option is pumped hydro power where surplus electricity (e.g. electricity produced overnight by base-load coal or nuclear power) is used to pump water from a lower to an upper reservoir. The stored energy is then used to produce hydropower during daily high-demand periods. Pumped hydro plants are large-scale storage systems with a typical efficiency between 70% and 80%, which means that a quarter of the energy is lost in the process. Other storage technologies with different characteristics (i.e. storage process and capacity, conversion back to electricity and response to power demand, energy losses and costs) are currently in demonstration or pre-commercial stages and discussed in this brief report: Compressed air energy storage (CAES) systems, Flywheels; Electrical batteries; Supercapacitors; Superconducting magnetic storage; and Thermal energy storage. No single electricity storage technology scores high in all dimensions. The technology of choice often depends on the size of the system, the specific service, the electricity sources and the marginal cost of peak electricity. Pumped hydro currently accounts for 95% of the global storage capacity and still offers a considerable expansion potential but does not suit residential or small-size applications. CAES expansion is limited due to the lack of suitable

  15. The low temperature specific heat and electrical transport, magnetic properties of Pr{sub 0.65}Ca{sub 0.35}MnO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Han, Zhiyong, E-mail: zyhan@cauc.edu.cn

    2017-02-01

    The magnetic properties, electrical transport properties, and low temperature specific heat of polycrystalline perovskite manganese oxide Pr{sub 0.65}Ca{sub 0.35}MnO{sub 3} have been investigated experimentally. It is found that there exists cluster glass state in the sample at low temperature besides the antiferromagnetic insulating state. With the increase of magnetic field, antiferromagnetic insulating state converts to ferromagnetic metal state and the Debye temperature decreases gradually. In addition, the low temperature electron specific heat in zero magnetic field is obviously larger than that of ordinary rare-earth manganites oxide and this phenomenon is related to the itinerant electrons in ferromagnetic cluster state and the disorder in Pr{sub 0.65}Ca{sub 0.35}MnO{sub 3}. - Highlights: • There exists cluster glass state in the sample at low temperature besides the antiferromagnetic insulating state. • With the increase of magnetic field, antiferromagnetic insulating state converts to ferromagnetic metal state. • Low temperature electron specific heat in zero magnetic field is larger than that of ordinary rare-earth manganites oxide.

  16. 42 CFR 412.73 - Determination of the hospital-specific rate based on a Federal fiscal year 1982 base period.

    Science.gov (United States)

    2010-10-01

    ... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM PROSPECTIVE PAYMENT SYSTEMS FOR... System for Inpatient Operating Costs § 412.73 Determination of the hospital-specific rate based on a... under the Social Security Act as in effect on April 19, 1983. (e) DRG adjustment. The applicable...

  17. Emergence of periodic order in electric-field-driven planar nematic liquid crystals: An exclusive ac effect absent in static fields

    Science.gov (United States)

    Krishnamurthy, K. S.; Kumar, Pramoda

    2007-11-01

    We report, for a nematic liquid crystal with a low conductivity anisotropy, an ac field generated transition from a uniformly planar to a periodically modulated director configuration with the wave vector parallel to the initial director. Significantly, with unblocked electrodes, this instability is not excited by dc fields. Additionally, in very low frequency square wave fields, it occurs transiently after each polarity reversal, vanishing completely during field constancy. The time of occurrence of maximum distortion after polarity reversal decreases exponentially with voltage. The time dependence of optical phase change during transient distortion is nearly Gaussian. The pattern threshold Vc is linear in f , f denoting the frequency; the critical wave number qc of the modulation scales nearly linearly as f to a peak at ˜50Hz before falling slightly thereafter. The observed Vc(f) and qc(f) characteristics differ from the predictions of the standard model (SM). The instability may be interpreted as a special case of the Carr-Helfrich distortion suppressed in static fields due to weak charge focusing and strong charge injection. Its transient nature in the low frequency regime is suggestive of the possible role of gradient flexoelectric effect in its occurrence. The study includes measurement of certain elastic and viscosity parameters relevant to the application of the SM.

  18. Sensitivity and specificity of a hand-held milk electrical conductivity meter compared to the California mastitis test for mastitis in dairy cattle.

    Science.gov (United States)

    Fosgate, G T; Petzer, I M; Karzis, J

    2013-04-01

    Screening tests for mastitis can play an important role in proactive mastitis control programs. The primary objective of this study was to compare the sensitivity and specificity of milk electrical conductivity (EC) to the California mastitis test (CMT) in commercial dairy cattle in South Africa using Bayesian methods without a perfect reference test. A total of 1848 quarter milk specimens were collected from 173 cows sampled during six sequential farm visits. Of these samples, 25.8% yielded pathogenic bacterial isolates. The most frequently isolated species were coagulase negative Staphylococci (n=346), Streptococcus agalactiae (n=54), and Staphylococcus aureus (n=42). The overall cow-level prevalence of mastitis was 54% based on the Bayesian latent class (BLC) analysis. The CMT was more accurate than EC for classification of cows having somatic cell counts >200,000/mL and for isolation of a bacterial pathogen. BLC analysis also suggested an overall benefit of CMT over EC but the statistical evidence was not strong (P=0.257). The Bayesian model estimated the sensitivity and specificity of EC (measured via resistance) at a cut-point of >25 mΩ/cm to be 89.9% and 86.8%, respectively. The CMT had a sensitivity and specificity of 94.5% and 77.7%, respectively, when evaluated at the weak positive cut-point. EC was useful for identifying milk specimens harbouring pathogens but was not able to differentiate among evaluated bacterial isolates. Screening tests can be used to improve udder health as part of a proactive management plan. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Specific activity of 137CS in food on the territory of the Republic of Serbia in the period 1986-2000

    International Nuclear Information System (INIS)

    Javorina, Lj.; Pantelic, G.; Tanaskovic, I.; Savkovic, M. Eremic; Vuletic, V.

    2002-01-01

    The population exposure to radiation results from both natural and man-produced radionuclides. Some of the elements are transported into the human organism via the food chain. Monitoring of radioactivity in the living environment includes vertical analysis system: air-precipitations-soil-water-plants-animals-man. Systematic examination of these samples is performed in specific points on the territory of the Republic of Serbia (without Kosovo and Metohija): Subotica, Novi Sad, Beograd, Uzice, Zajecar and Nis, and in specific time intervals (every day, every ten days, once a month, once in three months, every six months) using legally regulated methods. Contamination of human food is examined in the food products characteristic of the diet of the population (vegetables, fruit, meat, cereals, milk products and milk). The samples are collected twice a year (spring and fall). Milk samples are controlled each month in a composite sample of 10 L (0.3 L of milk is obtained every day) in Belgrade, Novi Sad, Nis and Zajecar. Activity of the long half-life radionuclide of artificial origin 1 37C s is determined in the samples, since it has particular significance in food cycle from the point of view of radiation hygiene, due to its longe half-life and radioactivity. 1 37C s activity is determined using gamma-spectrometric method. The method enables qualitative and quantitative analysis of radionuclides in different samples, and the advantage of the method lies in the fact that the samples may be measured only after minimal preparation based on their homogenization. The measurements were performed with a pure germanium detector with 25% efficiency and resolution of 1.85 keV (at 1.331 MeV)

  20. Influence of advections of particulate matter from biomass combustion on specific-cause mortality in Madrid in the period 2004-2009.

    Science.gov (United States)

    Linares, C; Carmona, R; Tobías, A; Mirón, I J; Díaz, J

    2015-05-01

    Approximately, 20 % of particulate and aerosol emissions into the urban atmosphere are of natural origin (including wildfires and Saharan dust). During these natural episodes, PM10 and PM2.5 levels usually exceed World Health Organisation (WHO) health protection thresholds. This study sought to evaluate the possible effect of advections of particulate matter from biomass fuel combustion on daily specific-cause mortality among the general population and the segment aged ≥ 75 years in Madrid. Ecological time-series study in the city of Madrid from January 01, 2004 to December 31, 2009. The dependent variable analysed was daily mortality due to natural (ICD-10:A00-R99), circulatory (ICD-10:I00-I99), and respiratory (ICD-10:J00-J99) causes in the population, both general and aged ≥ 75 years. The following independent and control variables were considered: a) daily mean PM2.5 and PM10 concentrations; b) maximum daily temperature; c) daily mean O3 and NO2 concentrations; d) advection of particulate matter from biomass combustion ( http://www.calima.ws/ ), using a dichotomous variable and e) linear trend and seasonalities. We conducted a descriptive analysis, performed a test of means and, to ascertain relative risk, fitted a model using autoregressive Poisson regression and stratifying by days with and without biomass advection, in both populations. Of the 2192 days analysed, biomass advection occurred on 56, with mean PM2.5 and PM10 values registering a significant increase during these days. PM10 had a greater impact on organic mortality with advection (RRall ages = 1.035 [1.011-1.060]; RR  ≥  75 years = 1.066 [1.031-1.103]) than did PM2.5 without advection (RRall ages = 1.017 [1.009-1.025]; RR  ≥  75 years = 1.012 [1.003-1.022]). Among specific causes, respiratory-though not circulatory-causes were associated with PM10 on days with advection in ≥ 75 year age group. PM10, rather than PM2.5, were associated with an increase in natural

  1. Electricity Generation Baseline Report

    Energy Technology Data Exchange (ETDEWEB)

    Logan, Jeffrey [National Renewable Energy Lab. (NREL), Golden, CO (United States); Marcy, Cara [National Renewable Energy Lab. (NREL), Golden, CO (United States); McCall, James [National Renewable Energy Lab. (NREL), Golden, CO (United States); Flores-Espino, Francisco [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bloom, Aaron [National Renewable Energy Lab. (NREL), Golden, CO (United States); Aabakken, Jorn [National Renewable Energy Lab. (NREL), Golden, CO (United States); Cole, Wesley [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jenkin, Thomas [National Renewable Energy Lab. (NREL), Golden, CO (United States); Porro, Gian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Liu, Chang [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ganda, Francesco [Argonne National Lab. (ANL), Argonne, IL (United States); Boardman, Richard [Idaho National Lab. (INL), Idaho Falls, ID (United States); Tarka, Thomas [National Energy Technology Lab. (NETL), Albany, OR (United States); Brewer, John [National Energy Technology Lab. (NETL), Albany, OR (United States); Schultz, Travis [National Energy Technology Lab. (NETL), Albany, OR (United States)

    2017-01-01

    This report was developed by a team of national laboratory analysts over the period October 2015 to May 2016 and is part of a series of studies that provide background material to inform development of the second installment of the Quadrennial Energy Review (QER 1.2). The report focuses specifically on U.S. power sector generation. The report limits itself to the generation sector and does not address in detail parallel issues in electricity end use, transmission and distribution, markets and policy design, and other important segments. The report lists 15 key findings about energy system needs of the future.

  2. Cut Electric Bills by Controlling Demand

    Science.gov (United States)

    Grumman, David L.

    1974-01-01

    Electric bills can be reduced by lowering electric consumption and by controlling demand -- the amount of electricity used at a certain point in time. Gives tips to help reduce electric demand at peak power periods. (Author/DN)

  3. Electricity pricing

    International Nuclear Information System (INIS)

    Wijayatunga, P.D.C.

    1994-01-01

    Electricity pricing in most countries, especially in the developing world, has been determined by traditional accounting criteria where it raises revenue requirements to cover the operating costs and a return on past and future capital investments in possible power systems. The use of economic principles to improve the total economic efficiency in the electricity industry is discussed. Basic marginal cost theory, long run marginal costing (LRMC) cost categories and rating periods, marginal capacity costs, marginal energy costs, consumer costs, short run marginal costing (SRMC), marginal cost of fuel, marginal cost of network losses, market clearing price, value of unserved energy and network quality of supply cost are discussed

  4. The integration of the periodic production in the liberalized electric power markets: from the technic expenditures to the economic taxes imposed by the operating rules of the markets; L'integration de la production intermittente dans les marches electriques liberalises: des surcouts techniques aux penalites economiques imposees par les regles de fonctionnement des marches

    Energy Technology Data Exchange (ETDEWEB)

    Menanteau, Ph.; Finon, D.; Lamy, M.L

    2003-03-01

    In the framework of the climatic change and the energy supply safety, the european directive aims to promote the renewable energy production in Europe. Some of the renewable energy sources, as the wind power or the micro-hydroelectric power, are naturally periodic. Their introduction in the electric networks will create problems because of this periodic nature, problems which are new for the electric network producers and managers. These problems generate technical expenditures, which may be compensate by the economic penalties of the electric power market operating. In this context the document details the expenditures associated to the periodicity, the economic penalties by an analysis of the british market and analyses the possibilities to limit these economic penalties in order to reduce the conflicts between the electric market liberalization and the promotion of the renewable energies development. (A.L.B.)

  5. Problem Periods

    Science.gov (United States)

    ... ovary syndrome. Read our information on PCOS for teens , and see your doctor if you think you may have PCOS. Major weight loss. Girls who have anorexia will often stop having periods. When to see ...

  6. Electricity and energy policy: french specificities and challenges in the european framework; Electricite et politique energetique: specificites francaises et enjeux dans le cadre europeen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-11-15

    In the today context of the electric power european market deregulation and the increase of the energy prices, the energy policy must change. The increase of the energy prices makes wonder the question of the competitiveness of the french economy: what type of supplies and which technological orientations will allow to reduce the constraints. After a presentation of the today electric power french market and the recently modifications bond to the deregulation, this note aims to describe the evolutions, since the first petroleum crisis, of the place given to the electric power in the energy policy, as the technological choices explaining the today structure he electricity production, characterized by the major part of the nuclear. Then the energy policy in matter of the electric power is discussed in the european context, to present the choices impacts facing the european objectives of energy security, environment and market liberalization. (A.L.B.)

  7. Optimizing the space-time-yield and the specific energy consumption of molten salt electrolysis processes for the electrowinning of metals in subgroups 4 and 5 of the periodic table of elements

    International Nuclear Information System (INIS)

    Koeck, W.

    1988-04-01

    Disadvantages of molten salt electrolysis are its low space-time-yield (kg/m 3 h) combined with its high specific energy consumption (kWh/kg). These factors essentially determine how electrolysis is applied on an industrial scale. The electrolysis of tantalum was selected as an example representative for other electrolytic processes; this series of tests allow statements also on the winning of the other elements from subgroups 4 and 5 of the periodic table, and on electrolytic aluminium extraction. Optimal operating conditions for direct current electrolysis were determined in the laboratory by varying the current density and the electrolysis temperature. In order to improve the space-time-yield from an existing electrolytic cell with a given electrolyte composition beyond the optimal range of direct current electrolysis, the process of periodic current reversal is applied. In this process, the polarity is reversed for a short time at constant periodic intervals. If the forward time period and the backward time period are chosen in a suitable way, both the current efficiency and the space-time-yield can be improved without increasing the energy consumption. 59 refs., 48 figs., 8 tabs. (Author)

  8. Congener-specific analysis of polychlorinated naphthalenes (PCNs) in the major Chinese technical PCB formulation from a stored Chinese electrical capacitor.

    Science.gov (United States)

    Huang, Jun; Yu, Gang; Yamauchi, Makoto; Matsumura, Toru; Yamazaki, Norimasa; Weber, Roland

    2015-10-01

    Impurity of polychlorinated naphthalenes (PCNs) in commercial polychlorinated biphenyl (PCB) formulations has been recognized as a relevant source of PCNs in the environment. Congener-specific analysis of most main PCB formulations has been accomplished previously, excluding the Chinese product. The insulating oil in a stored Chinese electric capacitor containing the major Chinese technical formulation "PCB3" was sampled and tested by isotope dilution technology using high-resolution gas chromatography coupled to high-resolution mass spectrometry (HRGC/HRMS). The detected concentration of PCNs in the Chinese PCB oil sample was 1,307.5 μg/g and therefore significantly higher than that reported in PCB formulations from other countries, as well as that in the transformer oil (ASKAREL Nr 1740) additionally tested in the present study for comparison. Based on the measurement, the total amount of PCNs in Chinese PCB3 oil is estimated to be 7.8 t, which would mean only 0.005 % of global production of PCNs of 150,000 t. The homolog profile is similar to those of PCN in Aroclor 1262 and Clophen A40, where the contributions from hexa-CNs and hepta-CNs are predominant and accounted for similar proportions. The Toxic Equivalent Quantity (TEQ) concentration of dioxin-like PCN congeners is 0.47 μg TEQ/g, with the dominant contributors of CN-73 and CN-66/67. This TEQ content from PCN is higher than that in most other PCB formulations with the exemption of the Russian Sovol formulation. The total TEQ in the historic 6,000 t of the Chinese PCB3 formulation is estimated to be 2.8 kg TEQ.

  9. Technical Specifications: Vogtle Electric Generating Plant, Unit Nos. 1 and 2 (Docket Nos. 50-424 and 50-425): Appendix ''A'' to License Nos. NPF-68 and NPF-79

    International Nuclear Information System (INIS)

    1989-02-01

    The Vogtle Electric Generating Plant, Unit Nos. 1 and 2, Technical Specifications were prepared by the US Nuclear Regulatory Commission to set forth the limits, operating conditions, and other requirements applicable to a nuclear facility as set forth in Section 50.36 of 10 CFR 50 for the protection of the health and safety of the public

  10. Technical Specifications, Vogtle Electric Generating Plant, Unit Nos. 1 and 2 (Docket Nos. 50-424 and 50-425): Appendix ''A'' to License Nos. NPF-68 and NPF-81

    International Nuclear Information System (INIS)

    1989-03-01

    The Vogtle Electric Generating Plant, Unit Nos. 1 and 2, Technical Specifications were prepared by the US Nuclear Regulatory Commission to set forth the limits, operating conditions, and other requirements applicable to a nuclear facility as set forth in Section 50.36 of 10 CFR 50 for the protection of the health and safety of the public

  11. A methodology for Electric Power Load Forecasting

    Directory of Open Access Journals (Sweden)

    Eisa Almeshaiei

    2011-06-01

    Full Text Available Electricity demand forecasting is a central and integral process for planning periodical operations and facility expansion in the electricity sector. Demand pattern is almost very complex due to the deregulation of energy markets. Therefore, finding an appropriate forecasting model for a specific electricity network is not an easy task. Although many forecasting methods were developed, none can be generalized for all demand patterns. Therefore, this paper presents a pragmatic methodology that can be used as a guide to construct Electric Power Load Forecasting models. This methodology is mainly based on decomposition and segmentation of the load time series. Several statistical analyses are involved to study the load features and forecasting precision such as moving average and probability plots of load noise. Real daily load data from Kuwaiti electric network are used as a case study. Some results are reported to guide forecasting future needs of this network.

  12. Volumes of radionuclide into the basins of water while the accident at the Chernobyl nuclear power station and a specifics of radiation situation development in the post-accidents periods

    International Nuclear Information System (INIS)

    Standritchuk, O.Z.; Maksin, V.I.; Goncharuk, V.V.

    1996-01-01

    There was stated total content of radionuclide pollution, rejected to the environment in consequence of the accident at the Chernobyl nuclear power station, specifics of qualitative and quantitative change which supposes the division of post-accident period into five conventional post-accident periods. There were given the data about the levels of main fragmentation radionuclide activity in river water, atmospheric precipitation and sewage of the objects of sanitary treatment in May 1986. According to these data there were estimated the volumes of radioactive pollution rejection to the Kiev basins of water (1.56 centre dot 10 10 Ku, that is equal to 144,57 kg of radionuclides or 3,67 % of their mass in reactor) and their going into the Dnieper river. There was shown an interconnection of all season state of water basins which are near to Chernobyl nuclear power station, with specific development of radiation situation in them after the accident. There was proposed a probated variant of improvement of the traditional technology of drinking water preparation from the open water source within 1-2 post-accident periods

  13. The language used in describing autobiographical memories prompted by life period visually presented verbal cues, event-specific visually presented verbal cues and short musical clips of popular music.

    Science.gov (United States)

    Zator, Krysten; Katz, Albert N

    2017-07-01

    Here, we examined linguistic differences in the reports of memories produced by three cueing methods. Two groups of young adults were cued visually either by words representing events or popular cultural phenomena that took place when they were 5, 10, or 16 years of age, or by words referencing a general lifetime period word cue directing them to that period in their life. A third group heard 30-second long musical clips of songs popular during the same three time periods. In each condition, participants typed a specific event memory evoked by the cue and these typed memories were subjected to analysis by the Linguistic Inquiry and Word Count (LIWC) program. Differences in the reports produced indicated that listening to music evoked memories embodied in motor-perceptual systems more so than memories evoked by our word-cueing conditions. Additionally, relative to music cues, lifetime period word cues produced memories with reliably more uses of personal pronouns, past tense terms, and negative emotions. The findings provide evidence for the embodiment of autobiographical memories, and how those differ when the cues emphasise different aspects of the encoded events.

  14. Testing and development of electric vehicle batteries for EPRI Electric Transportation Program

    Science.gov (United States)

    1985-11-01

    Argonne National Laboratory conducted an electric-vehicle battery testing and development program for the Electric Power Research Institute. As part of this program, eighteen battery modules previously developed by Johnson Controls, Inc. were tested. This type of battery (EV-2300 - an improved state-of-the-art lead-acid battery) was designed specifically for improved performance, range, and life in electric vehicles. In order to obtain necessary performance data, the batteries were tested under various duty cycles typical of normal service. This program, supported by the Electric Power Research Institute, consisted of three tasks: determination of the effect of cycle life vs peak power and rest period, determination of the impact of charge method on cycle life, and evaluation of the EV-2300 battery system. Two supporting studies were also carried out: one on thermal management of electric-vehicle batteries and one on enhanced utilization of active material in lead-acid batteries.

  15. Realistic generation cost of solar photovoltaic electricity

    International Nuclear Information System (INIS)

    Singh, Parm Pal; Singh, Sukhmeet

    2010-01-01

    Solar photovoltaic (SPV) power plants have long working life with zero fuel cost and negligible maintenance cost but requires huge initial investment. The generation cost of the solar electricity is mainly the cost of financing the initial investment. Therefore, the generation cost of solar electricity in different years depends on the method of returning the loan. Currently levelized cost based on equated payment loan is being used. The static levelized generation cost of solar electricity is compared with the current value of variable generation cost of grid electricity. This improper cost comparison is inhibiting the growth of SPV electricity by creating wrong perception that solar electricity is very expensive. In this paper a new method of loan repayment has been developed resulting in generation cost of SPV electricity that increases with time like that of grid electricity. A generalized capital recovery factor has been developed for graduated payment loan in which capital and interest payment in each installment are calculated by treating each loan installment as an independent loan for the relevant years. Generalized results have been calculated which can be used to determine the cost of SPV electricity for a given system at different places. Results show that for SPV system with specific initial investment of 5.00 cents /kWh/year, loan period of 30 years and loan interest rate of 4% the levelized generation cost of SPV electricity with equated payment loan turns out to be 28.92 cents /kWh, while the corresponding generation cost with graduated payment loan with escalation in annual installment of 8% varies from 9.51 cents /kWh in base year to 88.63 cents /kWh in 30th year. So, in this case, the realistic current generation cost of SPV electricity is 9.51 cents /kWh and not 28.92 cents /kWh. Further, with graduated payment loan, extension in loan period results in sharp decline in cost of SPV electricity in base year. Hence, a policy change is required

  16. The electricity prices in the European Union. The role of renewable energies and regulatory electric market reforms

    International Nuclear Information System (INIS)

    Moreno, Blanca; López, Ana J.; García-Álvarez, María Teresa

    2012-01-01

    The European Union electricity market has been gradually liberalized since 1990s. Theoretically, competitive markets should lead to efficiency gains in the economy thus reducing electricity prices. However, there is a controversial debate about the real effects of the electricity liberalization on electricity prices. Moreover, the increased generation of electricity from renewable energies RES-E (Electricity from Renewable Energy Sources) is also integrated in wholesale market reducing wholesale prices, but the final effect over household prices is not clear. In order to contribute to this debate, this paper provides an empirical investigation into the electricity prices determinants. In fact we develop econometric panel models to explore the relationship between the household electricity prices and variables related to the renewable energy sources and the competition in generation electricity market. More specifically we use a panel data set provided by Eurostat and covering 27 European Union countries during the period 1998–2009. Our results suggest that electricity prices increase with the deployment of RES-E and with the expansion of greenhouse gas emissions produced by energy industries- as a European Union CO 2 emission trading scheme exists. Results also reveal that country's characteristics can affect household electricity prices. -- Highlights: ► Electricity liberalized markets should lead to reduce electricity prices. ► The use of renewable energies (RES) reduce wholesale electricity prices. ► However, household electricity prices are increasing in European Union. ► Panel data models are developed to investigate the effect of RES and electricity competition on household electricity prices. ► We find that the deployment of RES increases prices paid by consumers in a liberalized market.

  17. Electricity and energy policy: French specificities and stakes in the European framework; Electricite et politique energetique: specificites francaises et enjeux dans le cadre europeen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-15

    The present day context of liberalization of European power markets and increase of energy prices raises the question of the competitiveness of the French economy: what type of supply and what technological trend would allow to relax this constrain? It is therefore the overall main trends of the French energy policy that should be reexamined in the broader framework of Europe. This is the aim of this document. It presents, first, the present day organization of the French power market and the recent changes that have followed its opening to competition. Then, it describes the evolutions since the first petroleum shock and the share given to electricity in the French energy mix, the technological choices that have led to the present day domination of nuclear energy in the power generation means. Finally, this policy and its perspectives is compared to the main European trends in the domain of energy security, environment protection and market liberalization. It appears, in particular, that the choices made by France in the domain of electricity (demand mastery efforts, large share given to electricity, preponderance of nuclear power, development of renewable energy sources, in particular hydroelectric power) have limited its energy bill and enhanced its energy independence. Also, all energy sources considered, they have led to a low level of CO{sub 2} emissions with respect to other developed countries. (J.S.)

  18. Propulsion element requirements using electrical power system unscheduled power

    Science.gov (United States)

    Zimmermann, Frank; Hodge, Kathy

    1989-01-01

    The suitability of using the electrical energy from the Space Station's Electrical Power System (EPS) during the periods of peak solar insolation which is currently not specifically allocated (unscheduled power) to produce propulsion propellants, gaseous hydrogen, and oxygen by electrolyzing water is investigated. Reboost propellant requirements are emphasized, but the results are more generally relevant because the balance of recurring propellant requirements are an order of magnitude smaller and the nonrecurring requirements are not significant on an average basis.

  19. Patient-Specific Human Induced Pluripotent Stem Cell Model Assessed with Electrical Pacing Validates S107 as a Potential Therapeutic Agent for Catecholaminergic Polymorphic Ventricular Tachycardia.

    Directory of Open Access Journals (Sweden)

    Kenichi Sasaki

    Full Text Available Human induced pluripotent stem cells (hiPSCs offer a unique opportunity for disease modeling. However, it is not invariably successful to recapitulate the disease phenotype because of the immaturity of hiPSC-derived cardiomyocytes (hiPSC-CMs. The purpose of this study was to establish and analyze iPSC-based model of catecholaminergic polymorphic ventricular tachycardia (CPVT, which is characterized by adrenergically mediated lethal arrhythmias, more precisely using electrical pacing that could promote the development of new pharmacotherapies.We generated hiPSCs from a 37-year-old CPVT patient and differentiated them into cardiomyocytes. Under spontaneous beating conditions, no significant difference was found in the timing irregularity of spontaneous Ca2+ transients between control- and CPVT-hiPSC-CMs. Using Ca2+ imaging at 1 Hz electrical field stimulation, isoproterenol induced an abnormal diastolic Ca2+ increase more frequently in CPVT- than in control-hiPSC-CMs (control 12% vs. CPVT 43%, p<0.05. Action potential recordings of spontaneous beating hiPSC-CMs revealed no significant difference in the frequency of delayed afterdepolarizations (DADs between control and CPVT cells. After isoproterenol application with pacing at 1 Hz, 87.5% of CPVT-hiPSC-CMs developed DADs, compared to 30% of control-hiPSC-CMs (p<0.05. Pre-incubation with 10 μM S107, which stabilizes the closed state of the ryanodine receptor 2, significantly decreased the percentage of CPVT-hiPSC-CMs presenting DADs to 25% (p<0.05.We recapitulated the electrophysiological features of CPVT-derived hiPSC-CMs using electrical pacing. The development of DADs in the presence of isoproterenol was significantly suppressed by S107. Our model provides a promising platform to study disease mechanisms and screen drugs.

  20. An evaluation of the effect of age and the peri-parturient period on bone metabolism in dairy cows as measured by serum bone-specific alkaline phosphatase activity and urinary deoxypyridinoline concentration.

    Science.gov (United States)

    Sato, Reiichiro; Onda, Ken; Kato, Hajime; Ochiai, Hideharu; Kawai, Kazuhiro; Iriki, Tsunenori; Kaneko, Kazuyuki; Yamazaki, Yukio; Wada, Yasunori

    2013-08-01

    Various biochemical markers help to evaluate the state of bone turnover in humans and could be used during the peri-parturient period in dairy cows when calcium (Ca) metabolism changes dramatically. To investigate this, the peri-partum characteristics of serum bone-specific alkaline phosphatase (BAP) and urinary deoxypyridinoline (DPD) were investigated. Both serum BAP activity and urinary DPD concentrations were increased and demonstrated wide variability in younger animals, and these findings were consistent with other bone turnover markers. Around the time of parturition, serum Ca concentration and serum BAP activity in multiparous cows were significantly lower than in primiparous cows, but urinary DPD concentration was unchanged. The use of BAP as a bone formation marker appears to be valuable for evaluating bone remodelling status in cows, but the specificity of the test needs to be confirmed. The DPD/BAP ratio around parturition demonstrated a clear difference in bone turnover status between the two parity groups with multiparous cows demonstrating increased signs of bone resorption compared with primiparous cows, corresponding to the Ca requirement for milk production. In future studies, the applicability of the ratio of bone resorption marker to bone formation marker should be evaluated for bone turnover assessment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Delineation of site-specific management units in a saline region at the Venice Lagoon margin, Italy, using soil reflectance and apparent electrical conductivity

    Science.gov (United States)

    Site-specific crop management utilizes site-specific management units (SSMUs) to apply inputs when, where, and in the amount needed to increase food productivity, optimize resource utilization, increase profitability, and reduce detrimental environmental impacts. It is the objective of this study to...

  2. Electrical deregulation

    International Nuclear Information System (INIS)

    Simpson, R.

    2001-01-01

    Deregulation in the electricity sector took effect on January 1, 2001 in Alberta. Business consumers discovered that their electricity rates had almost doubled in a one-month period. The government argued that it was the case of short term pain for long term gain. The intent of the deregulation is the lowering of prices through competition. This principle applies when the supply meets the demand, but when the demand exceeds the supply, prices increase. When initial plans were made for the deregulation of the sector, utilities did not invest huge amounts of capital to build new generation plants, as it was not known how they would fare in the deregulated environment. This situation was compounded by the fact that there was an economic boom around the same time in Alberta, adding to the demands made on the existing generation infrastructure (approximately 4 per cent per year over the past decade). At the moment, some resource developers such as Syncrude, Amoco, and Daishowa produce their own electricity and export their excess capacity to the provincial grid for general use. The rules of the deregulated market have been clarified and a number of utilities are planning new generation plants and facilities. TransAlta, EPCOR, and Enmax Corp. have announced plans to expand or build new coal-fired plants. Alberta has an estimated 35 billion tonnes of recoverable coal, and 25 million tonnes of coal were used in 1999 to produce 75 per cent of the electricity required in Alberta. Over the next ten years, 4,000 megawatts of new capacity is planned, representing a 50 per cent increase over current levels. AES Corporation, a Virginia power giant, has also announced plans to build a generator in Alberta

  3. Influence of nonmagnetic disorder on specific heat and electrical resistivity in Kondo lattice system CePd{sub 1−x}Ge{sub x}In

    Energy Technology Data Exchange (ETDEWEB)

    Gnida, D., E-mail: d.gnida@int.pan.wroc.pl [Institute of Low Temperature and Structure Research, Polish Academy of Sciences, 50-950 Wrocław (Poland); Dominyuk, N.; Zaremba, V. [Inorganic Chemistry Department, Ivan Franko Lviv National University, Kyryla and Mephodiya Str. 6, 79005 Lviv (Ukraine); Kaczorowski, D. [Institute of Low Temperature and Structure Research, Polish Academy of Sciences, 50-950 Wrocław (Poland)

    2015-02-15

    Highlights: • Interplay of Kondo and RKKY interactions in the presence of nonmagnetic disorder. • Suppression of the coherent Kondo state by nonmagnetic impurities. • Observation of quantum interference phenomena in Ce-based Kondo system. • Coexistence of incoherent Kondo effect and Altshuler-Aronov quantum correction. - Abstract: The alloy system CePd{sub 1−x}Ge{sub x}In with 0.1⩽x⩽0.4 was investigated by means of heat capacity and electrical resistivity measurements. Its low-temperature behavior has been found to be governed by the interplay of Kondo effect and Ruderman-Kittel-Kasuya-Yosida (RKKY) interactions in the presence of atomic disorder in nonmagnetic atoms sublattice. The coherent Kondo state, observed for CePdIn, gradually vanishes with increasing the Ge-content. The incoherent Kondo state, which characterizes Ge-rich alloys, appears very sensitive to applied magnetic field. The observed systematic changes in the temperature- and field-dependent electrical transport in CePd{sub 1−x}Ge{sub x}In manifest the important role of quantum correction due to electron-electron interactions in weakly localized regime.

  4. Electrical conductivity testing of corn seeds as influenced by temperature and period of storage Teste de condutividade elétrica em sementes de milho armazenadas sob diferentes temperaturas e períodos

    Directory of Open Access Journals (Sweden)

    Simone Aparecida Fessel

    2006-10-01

    Full Text Available The objective of this work was to evaluate the effects of temperature (10, 20, 30, 20/10 and 30/10ºC and period of storage on electrical conductivity (EC in four seed lots of corn (Zea mays L., as well as the mineral composition of the soaking solution. EC test determines indirectly the integrity of seed membrane systems, and is used for the assessment of seed vigor, because this test detects the seed deterioration process since its early phase. The research comprised determinations of water content, germination, accelerated aging (AA, cold (CT and EC vigor tests, and determinations of Ca2+, Mg2+ and K+ release to the solution, after seed soaking of four corn seed lots. The evaluations were performed each four months during a period of 16 months. For statistical analysis, a completely randomized split plot design was used with eight replications. Except for seed lots stored at 10ºC, all vigor evaluations revealed a decline in vigor, but AA and CT showed more sensitiveness to declines of seed physiological quality than EC. Potassium was the main leached ion regardless of the storage temperature.O objetivo deste estudo foi verificar o efeito da temperatura (10, 20, 30, 20/10 e 30/10ºC e do período de armazenamento, sobre os resultados do teste de condutividade elétrica e, também, sobre a composição mineral da solução de embebição de quatro lotes de sementes de milho. O teste de condutividade elétrica baseia-se na integridade do sistema de membranas celulares, e é usado para a determinação do vigor de sementes, pois permite detectar as primeiras manifestações do processo de deterioração. Foram determinados: o teor de água das sementes, a germinação, vigor (testes de envelhecimento acelerado, de frio e de condutividade elétrica e os conteúdos de Ca2+, Mg2+ e K+ na solução de embebição das sementes, usada para determinar a condutividade elétrica. Para a análise estatística foi usado o delineamento inteiramente

  5. Electricity economics. Production functions with electricity

    International Nuclear Information System (INIS)

    Hu, Zhaoguang; Hu, Zheng

    2013-01-01

    The first book studies on the economics of electricity consumption. Compares the sector production functions with electricity and the commercial production functions with electricity. Introduces the global E-GDP function, the European E-GDP function and 12 national E-GDP functions. Presents the gene characters of EAI production functions and E-GDP functions for USA to see why USA's economy is entering an up-industrialization period. Discusses China's economic growth by production functions with electricity. Electricity Economics: Production Functions with Electricity studies the production output from analyzing patterns of electricity consumption. Since electricity data can be used to measure scenarios of economic performance due to its accuracy and reliability, it could therefore also be used to help scholars explore new research frontiers that directly and indirectly benefits human society. Our research initially explores a similar pattern to substitute the Cobb-Douglas function with the production function with electricity to track and forecast economic activities. The book systematically introduces the theoretical frameworks and mathematical models of economics from the perspective of electricity consumption. The E-GDP functions are presented for case studies of more than 20 developed and developing countries. These functions also demonstrate substantial similarities between human DNA and production functions with electricity in terms of four major characteristics, namely replication, mutation, uniqueness, and evolution. Furthermore, the book includes extensive data and case studies on the U.S., China, Japan, etc. It is intended for scientists, engineers, financial professionals, policy makers, consultants, and anyone else with a desire to study electricity economics as well as related applications.

  6. Electricity economics. Production functions with electricity

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Zhaoguang [State Grid Energy Research Institute, Beijing (China); Hu, Zheng [Delaware Univ., Newark, DE (United States)

    2013-07-01

    The first book studies on the economics of electricity consumption. Compares the sector production functions with electricity and the commercial production functions with electricity. Introduces the global E-GDP function, the European E-GDP function and 12 national E-GDP functions. Presents the gene characters of EAI production functions and E-GDP functions for USA to see why USA's economy is entering an up-industrialization period. Discusses China's economic growth by production functions with electricity. Electricity Economics: Production Functions with Electricity studies the production output from analyzing patterns of electricity consumption. Since electricity data can be used to measure scenarios of economic performance due to its accuracy and reliability, it could therefore also be used to help scholars explore new research frontiers that directly and indirectly benefits human society. Our research initially explores a similar pattern to substitute the Cobb-Douglas function with the production function with electricity to track and forecast economic activities. The book systematically introduces the theoretical frameworks and mathematical models of economics from the perspective of electricity consumption. The E-GDP functions are presented for case studies of more than 20 developed and developing countries. These functions also demonstrate substantial similarities between human DNA and production functions with electricity in terms of four major characteristics, namely replication, mutation, uniqueness, and evolution. Furthermore, the book includes extensive data and case studies on the U.S., China, Japan, etc. It is intended for scientists, engineers, financial professionals, policy makers, consultants, and anyone else with a desire to study electricity economics as well as related applications.

  7. Electrical cardioversion

    Science.gov (United States)

    Sucu, Murat; Davutoglu, Vedat; Ozer, Orhan

    2009-01-01

    External electrical cardioversion was first performed in the 1950s. Urgent or elective cardioversions have specific advantages, such as termination of atrial and ventricular tachycardia and recovery of sinus rhythm. Electrical cardioversion is life-saving when applied in urgent circumstances. The succcess rate is increased by accurate tachycardia diagnosis, careful patient selection, adequate electrode (paddles) application, determination of the optimal energy and anesthesia levels, prevention of embolic events and arrythmia recurrence and airway conservation while minimizing possible complications. Potential complications include ventricular fibrillation due to general anesthesia or lack of synchronization between the direct current (DC) shock and the QRS complex, thromboembolus due to insufficient anticoagulant therapy, non-sustained VT, atrial arrhythmia, heart block, bradycardia, transient left bundle branch block, myocardial necrosis, myocardial dysfunction, transient hypotension, pulmonary edema and skin burn. Electrical cardioversion performed in patients with a pacemaker or an incompatible cardioverter defibrillator may lead to dysfunction, namely acute or chronic changes in the pacing or sensitivity threshold. Although this procedure appears fairly simple, serious consequences might occur if inappropriately performed. PMID:19448376

  8. Electricity demand in Tunisia

    International Nuclear Information System (INIS)

    Gam, Imen; Ben Rejeb, Jaleleddine

    2012-01-01

    This paper examines the global electricity demand in Tunisia as a function of gross domestic product in constant price, the degree of urbanization, the average annual temperature, and the real electricity price per Kwh. This demand will be examined employing annual data over a period spanning almost thirty one years from 1976 to 2006. A long run relationship between the variables under consideration is determined using the Vector Autoregressive Regression. The empirical results suggest that the electricity demand in Tunisia is sensitive to its past value, any changes in gross domestic product and electricity price. The electricity price effects have a negative impact on long-run electricity consumption. However, the gross domestic product and the past value of electricity consumption have a positive effect. Moreover, the causality test reveals a unidirectional relationship between price and electricity consumption. Our empirical findings are effective to policy makers to maintain the electricity consumption in Tunisia by using the appropriate strategy. - Highlights: ► This paper examined the electricity demand in Tunisia in the long-run. ► The empirical analysis revealed that in the long-run the electricity demand is affected by changes in its past value, GDP in constant price and real electricity price. ► There is a unidirectional relationship between price and electricity consumption, that is to say, that the electricity price causes the consumption. ► Those results suggest that a pricing policy can be an effective instrument to rationalize the electricity consumption in Tunisia in the long-run.

  9. On the electricity shortage, price and electricity theft nexus

    International Nuclear Information System (INIS)

    Jamil, Faisal

    2013-01-01

    Pakistan is facing severe electricity shortfall of its history since 2006. Several measures have been implemented in order to mitigate electricity shortage. The focus has been on raising the installed capacity of electricity generation and transmission. The present policy results in expensive thermal electricity generation mostly using expensive and environmentally hazardous furnace oil and inability of utilities to recover their cost of supply although there is unprecedented rise in electricity tariffs. This study concentrates on the electricity demand and traces the relationship between electricity shortfalls, tariff rate and electricity theft in the background of recent electricity crisis using the data for the period 1985–2010. We employed the Granger causality test through error correction model and out-of-sample causality through variance decomposition method. Empirical evidence shows that electricity theft greatly influences electricity shortfalls through lowering investment and inefficient use of electricity. The study concludes that electricity crisis cannot be handled without combating rampant electricity theft in the country. - Highlights: ► The study investigates relationship among electricity outages, price and electricity theft. ► It employed Johansen approach, ECM and variance decomposition analysis. ► Empirical evidence shows that electricity theft causes outages and rising tariff rates. ► Variance decomposition analysis results are slightly different from ECM

  10. [Status-specific differences in the occurrence of overweight and obesity in the transitional period from childhood to adolescence - results from the cross-sectional German KiGGS study].

    Science.gov (United States)

    Krause, L; Lampert, T

    2014-06-01

    Individual studies point out that health inequalities decrease in the transitional period from childhood to adolescence. However, there is evidence that this effect can vary depending on the health aspect that is used. The present study analyses this effect for overweight and obesity. Representative data was obtained from a subsample (3-17 years, n=14,836) of the German Health Interview and Examination Survey for Children and Adolescents (KiGGS) which was conducted by the Robert Koch Institute from May 2003 to May 2006. Body height and weight were measured and body mass index (BMI) was calculated. Overweight and obesity are defined based on gender- and age-specific percentiles of BMI of the German reference system developed by Kromeyer-Hauschild and her colleagues. Socio-economic status (SES) was taken from information about parents' income, occupational status and education. Boys and girls with low SES show the highest prevalence of overweight and obesity in all age groups, those with high SES the lowest. While the results indicate a constant impact of SES on the risk for overweight and obesity in boys, the status differences increase over the age groups in girls. Regarding the whole age range, boys with low SES possess a 2.0-fold increased risk for overweight, and a 2.2-fold increased risk for obesity compared to boys with high SES. Girls from low status group even have a 2.8-fold risk to become overweight, and a 4.4-fold risk to become obese in comparison to the reference group. The findings reveal that SES has a significant impact on the occurrence of overweight and obesity in childhood and in particular adolescence. Therefore, the results underline the relevance of early childhood prevention in specific target groups and promotion of a healthy life style. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Sustainable Use of Electricity

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    1998-01-01

    An overview is presented of the need for keeping electricity consumption low, including a suggested definition of sustainable development. Specific attention is devoted to present and future electricity production´s contribution to the environmental problems. Prognoses are shown from before any...

  12. Decision support for the definition of wind turbine systems adequacy to site specificities and weak electrical networks; Aide a la decision pour la definition d'un systeme eolien, adequation au site et a un reseau faible

    Energy Technology Data Exchange (ETDEWEB)

    Arbaoui, A

    2006-10-15

    A decision support system for the definition of wind turbine systems is developed by taking into account the wind and site characteristics, the wind turbine components and the electrical network properties close to the site. The approach is based on functional analysis, on the investigation of the functional fluxes and on the definition of a model suitable for supporting decision at the preliminary stages of wind turbine design. The complete set of solutions derived from the model is determined using a Constraint Satisfaction Problem solver. The intrinsic capability of the model to support decision is derived from the investigation of the model parsimony, precision, exactness and specialization. The model takes into account performance criteria resulting from knowledge of manufacturers, distributors and investors. These criteria are used to discriminate design alternatives. Design alternatives correspond to choices of site (wind, electric network) and wind turbine architectures (related to 7 design variables). Performance criteria are the cost of electric kWh, the amount of energy being produced and the discounted total cost of the project. Electric network connection to wind turbines is taken into account through slow variations of the voltage and Flickers phenomenon. First, the maximal rate of penetration of the wind turbine energy production is determined. Next, two design alternatives have been investigated to improve wind turbine system integration in electric distribution networks. These alternatives are a reactive power control system and an inertial energy storage system. Inertial storage systems seem to be more expensive than reactive power control systems for this type of application. The influence of site specificities on decision making process has been established through three different sites (a Mediterranean site and two sites located in northern Europe). Profits relative to the cost of kWh appear to be high for Mediterranean sites. Most of the

  13. Decision support for the definition of wind turbine systems adequacy to site specificities and weak electrical networks; Aide a la decision pour la definition d'un systeme eolien, adequation au site et a un reseau faible

    Energy Technology Data Exchange (ETDEWEB)

    Arbaoui, A

    2006-10-15

    A decision support system for the definition of wind turbine systems is developed by taking into account the wind and site characteristics, the wind turbine components and the electrical network properties close to the site. The approach is based on functional analysis, on the investigation of the functional fluxes and on the definition of a model suitable for supporting decision at the preliminary stages of wind turbine design. The complete set of solutions derived from the model is determined using a Constraint Satisfaction Problem solver. The intrinsic capability of the model to support decision is derived from the investigation of the model parsimony, precision, exactness and specialization. The model takes into account performance criteria resulting from knowledge of manufacturers, distributors and investors. These criteria are used to discriminate design alternatives. Design alternatives correspond to choices of site (wind, electric network) and wind turbine architectures (related to 7 design variables). Performance criteria are the cost of electric kWh, the amount of energy being produced and the discounted total cost of the project. Electric network connection to wind turbines is taken into account through slow variations of the voltage and Flickers phenomenon. First, the maximal rate of penetration of the wind turbine energy production is determined. Next, two design alternatives have been investigated to improve wind turbine system integration in electric distribution networks. These alternatives are a reactive power control system and an inertial energy storage system. Inertial storage systems seem to be more expensive than reactive power control systems for this type of application. The influence of site specificities on decision making process has been established through three different sites (a Mediterranean site and two sites located in northern Europe). Profits relative to the cost of kWh appear to be high for Mediterranean sites. Most of the

  14. [Electrical storm].

    Science.gov (United States)

    Barnay, C; Taieb, J; Morice, R

    2007-11-01

    Electrical storm is defined as repeated occurrence of severe ventricular arrhythmias requiring multiple cardioversions, two or more or three or more following different studies. The clinical aspect can sometimes be made of multiple, self aggravating, life threatening accesses. There are three main clinical circumstances of occurrence: in patients equipped with intracardiac defibrillators, during the acute phase of myocardial infarction and in Brugada syndrome. 10 to 15% of patients with cardiac defibrillators are subject to electrical storms in a period of two years. The causative arrhythmia is most often ventricular tachycardia than ventricular fibrillation, especially in secondary prevention and if the initial arrhythmias justifying the device was a ventricular tachycardia. Precipitaing factors are present in one third of cases, mainly acute heart failure, ionic disorders and arrhythmogenic drugs. Predictive factors are age, left ventricular ejection fractionelectrical shock in 50% of cases, antitachycardi stimulation in 30% and in 20% by association of the two. Treatment, after elimination of inappropriate shocks, is mainly based on beta-blockers and amiodarone, class I antiarrhythmics, lidocaïne or bretylium in some cases, and sedation pushed to general anesthesia in some cases. Radio-frequency ablation and even heart transplantation have been proposed in extreme cases. Quinidine has been proved efficient in cases of Brugada syndrome.

  15. Electricity market models and RES integration: The Greek case

    International Nuclear Information System (INIS)

    Simoglou, Christos K.; Biskas, Pandelis N.; Vagropoulos, Stylianos I.; Bakirtzis, Anastasios G.

    2014-01-01

    This paper presents an extensive analysis of the Greek electricity market for the next 7-year period (2014–2020) based on an hour-by-hour simulation considering five different RES technologies, namely wind, PV, small hydro, biomass and CHP with emphasis on PV integration. The impact of RES penetration on the electricity market operation is evaluated under two different models regarding the organization of the Greek wholesale day-ahead electricity market: a mandatory power pool for year 2014 (current market design) and a power exchange for the period 2015–2020 (Target Model). An integrated software tool is used for the simulation of the current and the future day-ahead market clearing algorithm of the Greek wholesale electricity market. Simulation results indicate the impact of the anticipated large-scale RES integration, in conjunction with each market model, on specific indicators of the Greek electricity market in the long-term. - Highlights: • Analysis of the Greek electricity market for the next 7-year period (2014–2020) based on hour-by-hour simulation. • Five different RES technologies are considered with emphasis on PV integration. • A power pool (for 2014) and a power exchange (for 2015–2020) are considered. • Various market indicators are used for the analysis of the impact of the RES integration on the Greek electricity market. • Two alternative tariff schemes for the compensation of the new ground-mounted PV units from 2015 onwards are investigated

  16. Electricity Theory

    International Nuclear Information System (INIS)

    Gong, Ha Soung

    2006-12-01

    The text book composed of five parts, which are summary of this book, arrangement of electricity theory including electricity nad magnetism, a direct current, and alternating current. It has two dictionary electricity terms for a synonym. The last is an appendix. It is for preparing for test of officer, electricity engineer and fire fighting engineer.

  17. Optical Frequency Mixing in Periodically-Patterned and in Quasi-Periodically-Patterned Nonlinear media

    International Nuclear Information System (INIS)

    Arie, A.

    1999-01-01

    Nonlinear frequency mixing processes, e.g. second harmonic generation, sum and difference frequency generation, etc., require matching of the phases of the interacting waves. The traditional method to achieve it is by selecting a specific angle of propagation in a birefringent nonlinear crystal. The main limitation of the birefringent phase matching method stems from the fact that for many interesting interactions, the phase matching condition cannot be satisfied in a specific crystal. This obstacle can be removed by the technique of quasi-phase-matching (QPM), where the nonlinear coefficient of the material is modulated at a fixed spatial frequency that equals the wave-vector phase mismatch between the interacting waves. An important development in recent years is the ability to periodically reverse the sign of the nonlinear coefficient in ferroelectric crystals by applying a high electric field through a periodic electrode. Some recent QPM interactions in periodically-poled KTP that were recently achieved at Tel-Aviv University include continuous-wave optical parametric oscillations, as well as generation of tunable mid-infrared radiation by difference frequency generation. Periodic patterning of the nonlinear coefficient enables to phase match only a single interaction. It would be advantageous to further extend the applications of this technique in order to simultaneously satisfy several interactions on a single crystal. This cannot be usually achieved in a periodic pattern, however more sophisticated quasi-periodic structures can be designed in this case. An interesting analogy can be drawn between artificially-made quasi-periodically-patterned nonlinear crystals and quasi-crystals found in nature, in rapidly-cooled metallic alloys

  18. Solar PV electricity and market characteristics: two Canadian case-studies

    International Nuclear Information System (INIS)

    Rowlands, I.H.

    2005-01-01

    To determine whether solar electricity (that is, electricity generated by photovoltaics) is, on an average, more valuable - in market terms - than the electricity generated in power systems as a whole, this article investigates the extent to which solar resource availability in two Canadian locations is associated with peak electricity market demand and peak electricity market price. More specifically, solar radiation and electricity market data for the period 1 May 2002 to 30 April 2004 are examined for Calgary, Alta. and Guelph, Ont. A variety of visual and statistical investigations reveal that solar radiation values coincide closely with peak electricity market demand and, though to a somewhat lesser extent, peak electricity market prices during the summertime in each location. While more detailed investigation is needed in order to determine the specific impact of different levels of PV penetration upon provincial electricity markets, the article provides ample encouragement for further research. The article also shows how different techniques can be used-in any location-to investigate the relationship among solar electricity potential, system-wide demand and market prices. With electricity industries being restructured around the world, it continues to be important for solar energy proponents to participate in discussions regarding economic costs and benefits. Techniques used in this article can help them advance the solar electricity case more effectively and thus catalyse the deployment of photovoltaics in markets around the world. (author)

  19. Geothermal electricity generation

    International Nuclear Information System (INIS)

    Eliasson, E.T.

    1991-01-01

    Geothermal conversion, as discussed here, is the conversion of the heat bound within the topmost three kilometres of the upper crust of the earth into useful energy, principally electricity. The characteristics of a geothermal reservoir and its individual technical features are highly site-specific. Applications therefore must be designed to match the specific geothermal reservoir. An estimate of the electric energy potential world-wide made by the Electric Power Research Institute (United States) in 1978 and based on sustaining a continuous 30-year operation is given in the box at the right for comparison purposes only. 8 refs, 5 figs

  20. Specific features of design and electric circuit of the pulse modulator of the amplification channel of second-section linear accelerator for a meson factory

    International Nuclear Information System (INIS)

    Dyukov, L.V.; Fedorov, A.F.; Terekhov, V.F.

    1977-01-01

    The circuit and design of a modulator at pulse power of 15 MW and average power of 300 kW, intended for supplying a klystron generator, are described. The modulator is designed for operating in a lengthy mode. The capacitance storage-former is made in the form of three parallel sections of artificial shaping lines in order to lower the specific loads on the elements of the shaping line and thyristors. The thyristor spark gaps are made in the form of a unified water-cooled assembly composed of 12 series TD-320 thyristors. An assessment of the modulator reliability has shown that the average time-to-fault is 800 hr. Modulator tests confirm that the choice of the circuit solution is correct. The modulator total efficiency equals to approximately 0.9

  1. Electric field mapping and auroral Birkeland currents

    International Nuclear Information System (INIS)

    Kaufmann, R.L.; Larson, D.J.

    1989-01-01

    Magnetic field lines, electric fields and equipotentials have been mapped throughout the magnetosphere in the vicinity of strong Birkeland currents. It was found that a uniform electric field at either the ionospheric or the equatorial end of a field line can map to a highly structured field at the other end if strong Birkeland currents are located nearby. The initiation of sheet currents of the region 1 - region 2 scale size and intensity resulted in magnetic field line displacements of about 1/2 hour in local time between equatorial and ionospheric end points. As a result, a uniform dawn to dusk electric field at the equator mapped to an ionospheric electric field with strong inward pointing components in the dusk hemisphere. Similar distortions were produced by Birkeland currents associated with narrow east-west-aligned auroral arcs. A specific model for the auroral current system, based on ionospheric measurements during a large substorm, was used to study effects seen during disturbed periods. An iterative procedure was developed to generate a self-consistent current system even in the presence of highly twisted field lines. The measured ionospheric electric field was projected tot he equatorial plane in the presence of the model Birkeland current system. Several physical processes were seen to influence ionospheric and equatorial electric fields, and the associated plasma convection, during a substorm

  2. American Indian tribes and electric industry restructuring: Issues and opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Howarth, D. [Morse, Richard, and Weisenmiller, and Associates Inc., Oakland, CA (United States); Busch, J. [Lawrence Berkeley National Lab., CA (United States); Starrs, T. [Kelso, Starrs, and Associates LLC, Vashon, WA (United States)

    1997-07-01

    The US electric utility industry is undergoing a period of fundamental change that has significant implications for Native American tribes. Although many details remain to be determined, the future electric power industry will be very different from that of the present. It is anticipated that the new competitive electric industry will be more efficient, which some believe will benefit all participants by lowering electricity costs. Recent developments in the industry, however, indicate that the restructuring process will likely benefit some parties at the expense of others. Given the historical experience and current situation of Native American tribes in the US, there is good reason to pay attention to electric industry changes to ensure that the situation of tribes is improved and not worsened as a result of electric restructuring. This paper provides a review of electricity restructuring in the US and identifies ways in which tribes may be affected and how tribes may seek to protect and serve their interests. Chapter 2 describes the current status of energy production and service on reservations. Chapter 3 provides an overview of the evolution of the electric industry to its present form and introduces the regulatory and structural changes presently taking place. Chapter 4 provides a more detailed discussion of changes in the US electric industry with a specific focus on the implications of these changes for tribes. Chapter 5 presents a summary of the conclusions reached in this paper.

  3. Essays on electricity theft

    Science.gov (United States)

    Steadman, Keva Ullanda

    Electricity theft is a relatively unknown crime with high economic costs. In this dissertation, I try to identify the factors that motivate persons to steal electricity. First, I use a panel dataset of 97 countries spanning the five year period 2003--2007 to estimate a model that describes the effect of the unemployment rate, GDP per capita, male population and urbanization on theft, robbery and homicide rates. The results are consistent with previous empirical work on crime and economic opportunity. The second and main contribution of this paper is to estimate the same model using distribution loss as a proxy for electricity theft. The results show that the unemployment rate, a key explanatory economic factor for crime, cannot explain variation in electricity theft, although there is some evidence, albeit weak, supporting correlation in rich countries. Therefore, policies that target the reduction of property crime through a reduction in unemployment will have no effect on electricity theft. The third contribution relates to the role that political institutions play in the incentives to steal electricity. After control for socioeconomic factors, I find that there is no relationship between political governance indicators and electricity theft. In the second and third chapters, I compare the United States, a high income, low electricity theft country with Jamaica, a middle income, high electricity theft country. The effect of unemployment on electricity theft mirrors the results found in the first chapter. In the United States, electricity theft is affected by changes in economic conditions but in Jamaica, it is not. These results suggest that the state of institutions plays a role in how social norms are determined. Poor countries will be more likely than rich countries to have weak institutions with social norms that encourage electricity theft.

  4. Study of the reservoirs of Jurassic and Cretaceous periods in the south-cast slope of Central Kara-Kum vault using combination of acoustic logging, neutron-gamma logging, gamma logging, and electrical logging

    International Nuclear Information System (INIS)

    Meredov, T.M.; Baranov, M.I.

    1978-01-01

    Considered is the possibility of application of the combination of neutron-gamma logging, gamma logging al partitioncoustic logging and electrical logging to lithologica of sections, discovery reservoir layers in carbonate and terrigeneous sections as well as quantitative estimation of the porosity coefficients values at prospecting areas in the south-east slope of Central Kara-Kum vault. Neutron-gamma logging mostly makes it possible to partition carbonate rocks into limestones, dolomites and their interstitial variaties and to indicate sand stone layers with different degree of carbonate content

  5. An Economic Evaluation of Binary Cycle Geothermal Electricity Production

    National Research Council Canada - National Science Library

    Fitzgerald, Crissie

    2003-01-01

    .... Variables such as well flow rate, geothermal gradient and electricity prices were varied to study their influence on the economic payback period for binary cycle geothermal electricity production...

  6. Thyrotoxic periodic paralysis

    International Nuclear Information System (INIS)

    Ferreiro, J.E.; Arguelles, D.J.; Rams, H. Jr.

    1986-01-01

    A case of thyrotoxic periodic paralysis is reported in a Hispanic man with an unusual recurrence six weeks after radioactive iodine treatment. Thyrotoxic periodic paralysis has now been well characterized in the literature: it occurs primarily in Orientals with an overwhelming male preponderance and a higher association of specific HLA antigens. Clinical manifestations include onset after high carbohydrate ingestion or heavy exertion, with progressive symmetric weakness leading to flaccid paralysis of the extremities and other muscle groups, lasting several hours. If hypokalemia is present, potassium administration may help abort the attack. Although propranolol can be efficacious in preventing further episodes, the only definitive treatment is establishing a euthyroid state. The pathophysiology is still controversial, but reflects altered potassium and calcium dynamics as well as certain morphologic characteristics within the muscle unit itself

  7. Vertical integration of oil groups in gas downstream activities after the deregulation of gas and electricity industries: Determining factors and means of implementation of this strategy. Research report period: October 2000 - September 2003

    International Nuclear Information System (INIS)

    Benadjaoud, Nawel

    2003-12-01

    After a presentation of some characteristics of gas and electric power industries, and an overview of the process and consequences of the general trend of deregulation in these sectors, the author of this research proposes a contribution to the economic analysis of movements of vertical integration of large oil companies and groups in which downstream gas activities and power activities represent a small fraction of their activities. The objectives of this research were then to understand why oil companies are practising vertical integration on the gas sector, and how these oil companies proceed in terms of organisational means to perform this successful movement of vertical integration. The author addresses theoretical concepts as they are analysed in some theories of the firm. The studied questions are then addressed in the case of some major European oil companies through a detailed examination of all their operations related to the gas downstream activities and to electricity activities, and by examining the most used organisational modes for the implementation of such vertical integrations

  8. Electric emissions from electrical appliances

    International Nuclear Information System (INIS)

    Leitgeb, N.; Cech, R.; Schroettner, J.

    2008-01-01

    Electric emissions from electric appliances are frequently considered negligible, and standards consider electric appliances to comply without testing. By investigating 122 household devices of 63 different categories, it could be shown that emitted electric field levels do not justify general disregard. Electric reference values can be exceeded up to 11-fold. By numerical dosimetry with homogeneous human models, induced intra-corporal electric current densities were determined and factors calculated to elevate reference levels to accounting for reduced induction efficiency of inhomogeneous fields. These factors were found not high enough to allow generally concluding on compliance with basic restrictions without testing. Electric appliances usually simultaneously emit both electric and magnetic fields exposing almost the same body region. Since the sum of induced current densities is limited, one field component reduces the available margin for the other. Therefore, superposition of electric current densities induced by either field would merit consideration. (authors)

  9. Analysis and evaluation of the main factors that influence the growing of the electrical power consumption in the national electrical sector, period 2000-2005; Analisis y evaluacion de los principales factores que influyen en el crecimiento del consumo de energia electrica en el sector electrico nacional, periodo 2000-2005

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar Luna, Luis Miguel

    2008-06-15

    With the purpose of avoiding the installation of new transmission lines, some researches have proposed the installation of SIFLETCA devices. Therefore in this thesis, different models in steady state of diverse SIFLETCA devices are described, such as: compensator variable series (VSC), static compensator of VArs (SCV), transformer phase shifter (TPS), transformer with changer under load (TWCL) and the universal controller of power flows (UCPF). In addition, it is developed in this thesis the equations used in the Jacobean of the method Newton-Raphson, to solve power flows including SIFLETCA devices. The different applications that are obtained when installing a device, such as prevention of flows in ring, electronic barrier, increment in the transmission capacity and specification of the power flow in transmission lines. On the other hand in the thesis, an analysis of sensitivities of a power system in steady state is developed. Also the control parameters are proposed in the thesis for which the sensitivities are calculated. Also, a performance index is used to measure the degree of congestion of an electrical system. In calculating the sensitivities the obtained results of the power flows are utilized. Four electrical networks are used to find where each SIFLETCA device must be located to reduce the congestion in the system. Also, the method developed in the thesis is compared with a method of sensitivities that uses DC flows, for validation and to show the advantages of using the Newton method in power flows. [Spanish] Con el fin de evitar instalar nuevas lineas de transmision, algunos investigadores han propuesto la instalacion de los dispositivos SIFLETCA. Por lo tanto en esta tesis, se describe diferentes modelos en estado estacionario de diversos dispositivos SIFLETCA, siendo: compensador serie variable (CSV), compensador estatico de VArs (CEV), transformador desfasador (TD), transformador con cambiador bajo carga (TTC) y el controlador universal de flujos

  10. Electricity Customers

    Science.gov (United States)

    Residential, commercial, and industrial customers each account for roughly one-third of the nation’s electricity use. The transportation sector also accounts for a small fraction of electricity, although it could increase.

  11. Energy resource alternatives competition. Progress report for the period February 1, 1975--December 31, 1975. [Space heating and cooling, hot water, and electricity for homes, farms, and light industry

    Energy Technology Data Exchange (ETDEWEB)

    Matzke, D.J.; Osowski, D.M.; Radtke, M.L.

    1976-01-01

    This progress report describes the objectives and results of the intercollegiate Energy Resource Alternatives competition. The one-year program concluded in August 1975, with a final testing program of forty student-built alternative energy projects at the Sandia Laboratories in Albuquerque, New Mexico. The goal of the competition was to design and build prototype hardware which could provide space heating and cooling, hot water, and electricity at a level appropriate to the needs of homes, farms, and light industry. The hardware projects were powered by such nonconventional energy sources as solar energy, wind, biologically produced gas, coal, and ocean waves. The competition rules emphasized design innovation, economic feasibility, practicality, and marketability. (auth)

  12. Analysis of licensee event reports related to nuclear generating station onsite electrical system malfunctions, 1976-1978

    International Nuclear Information System (INIS)

    Bickel, J.H.; Abbott, E.C.

    1981-07-01

    This report summarizes the evaluation requested by the ACRS of 1177 LERS, submitted over a three year period, which related to onsite electrical system malfunctions. The evaluation was carried out for the purposes of identifying specific failure modes and consequences, evaluating the assumptions used in WASH-1400 on the reliability of electrical equipment, and identifying specific sequences which are significant to plant safety. The analysis performed provides a more specific identification of onsite electrical system failure modes, sequences, and consequences than was established in WASH-1400

  13. Electric drives

    CERN Document Server

    Boldea, Ion

    2005-01-01

    ENERGY CONVERSION IN ELECTRIC DRIVESElectric Drives: A DefinitionApplication Range of Electric DrivesEnergy Savings Pay Off RapidlyGlobal Energy Savings Through PEC DrivesMotor/Mechanical Load MatchMotion/Time Profile MatchLoad Dynamics and StabilityMultiquadrant OperationPerformance IndexesProblemsELECTRIC MOTORS FOR DRIVESElectric Drives: A Typical ConfigurationElectric Motors for DrivesDC Brush MotorsConventional AC MotorsPower Electronic Converter Dependent MotorsEnergy Conversion in Electric Motors/GeneratorsPOWER ELECTRONIC CONVERTERS (PECs) FOR DRIVESPower Electronic Switches (PESs)The

  14. Electrical contracting

    CERN Document Server

    Neidle, Michael

    2013-01-01

    Electrical Contracting, Second Edition is a nine-chapter text guide for the greater efficiency in planning and completing installations for the design, installation and control of electrical contracts. This book starts with a general overview of the efficient cabling and techniques that must be employed for safe wiring design, as well as the cost estimation of the complete electrical contract. The subsequent chapters are devoted to other electrical contracting requirements, including electronic motor control, lighting, and electricity tariffs. A chapter focuses on the IEE Wiring Regulations an

  15. Materials and electricity

    International Nuclear Information System (INIS)

    Jaffee, R.I.

    1986-01-01

    Despite an increase in the intensity of electricity usage, electricity has been reversing its historical trend of reduced cost since 1970 to the point where costs are increasing faster than inflation. Designers and operators on both sides of the meter and the developers of materials from which the electric system is constructed must contribute to the lowering of costs and an increase in reliability for the generation, transmission and distribution, and utilization of electricity. Four specific cases illustrate the role of materials/process improvements to this end. The examples highlight the use of forged or welded integral rotors, improvements in the heat rate of coal-fired plants through higher steam conditions and reduced heat losses, reduced losses through amorphous steel cores for transformers, and reduced ac electric motor losses through silicon variable speed drives. 37 references, 27 figures, 9 tables

  16. Electricity Bill [second reading

    International Nuclear Information System (INIS)

    Hooper, G.; Williams, C.C.P.; Ezra, D.

    1989-01-01

    The Parliamentary Under-Secretary at the Department of Energy introduced the second reading of the Electricity Bill which provides for the restructuring and privatisation of the electricity supply industry throughout Great Britain. Three features at the heart of the Government's proposals are mentioned - first that the proposals will promote competition in electricity generation and supply of electricity so there will be a downward pressure on costs and prices, second is a new deal for customers and third is the security of electricity supply which will be ensured by the diversity of suppliers. The benefits of the scheme are outlined and then specific details of the Bill are considered. The debate which followed lasted six hours and is reported verbatim. The issues raised included environmental effects, efficiency, energy conservation, research and development and investment. (UK)

  17. Trend analysis and modelling of gender-specific age, period and birth cohort effects on alcohol abstention and consumption level for drinkers in Great Britain using the General Lifestyle Survey 1984-2009.

    Science.gov (United States)

    Meng, Yang; Holmes, John; Hill-McManus, Daniel; Brennan, Alan; Meier, Petra Sylvia

    2014-02-01

    British alcohol consumption and abstinence rates have increased substantially in the last 3 decades. This study aims to disentangle age, period and birth cohort effects to improve our understanding of these trends and suggest groups for targeted interventions to reduce resultant harms. Age, period, cohort analysis of repeated cross-sectional surveys using separate logistic and negative binomial models for each gender. Great Britain 1984-2009. Annual nationally representative samples of approximately 20 000 adults (16+) within 13 000 households. Age (eight groups: 16-17 to 75+ years), period (six groups: 1980-84 to 2005-09) and birth cohorts (19 groups: 1900-04 to 1990-94). Outcome measures were abstinence and average weekly alcohol consumption. Controls were income, education, ethnicity and country. After accounting for period and cohort trends, 18-24-year-olds have the highest consumption levels (incident rate ratio = 1.18-1.15) and lower abstention rates (odds ratio = 0.67-0.87). Consumption generally decreases and abstention rates increase in later life. Until recently, successive birth cohorts' consumption levels were also increasing. However, for those born post-1985, abstention rates are increasing and male consumption is falling relative to preceding cohorts. In contrast, female drinking behaviours have polarized over the study period, with increasing abstention rates accompanying increases in drinkers' consumption levels. Rising female consumption of alcohol and progression of higher-consuming birth cohorts through the life course are key drivers of increased per capita alcohol consumption in the United Kingdom. Recent declines in alcohol consumption appear to be attributable to reduced consumption and increased abstinence rates among the most recent birth cohorts, especially males, and general increased rates of abstention across the study period. © 2013 Society for the Study of Addiction.

  18. Electric vehicles

    Science.gov (United States)

    1990-03-01

    Quiet, clean, and efficient, electric vehicles (EVs) may someday become a practical mode of transportation for the general public. Electric vehicles can provide many advantages for the nation's environment and energy supply because they run on electricity, which can be produced from many sources of energy such as coal, natural gas, uranium, and hydropower. These vehicles offer fuel versatility to the transportation sector, which depends almost solely on oil for its energy needs. Electric vehicles are any mode of transportation operated by a motor that receives electricity from a battery or fuel cell. EVs come in all shapes and sizes and may be used for different tasks. Some EVs are small and simple, such as golf carts and electric wheel chairs. Others are larger and more complex, such as automobile and vans. Some EVs, such as fork lifts, are used in industries. In this fact sheet, we will discuss mostly automobiles and vans. There are also variations on electric vehicles, such as hybrid vehicles and solar-powered vehicles. Hybrid vehicles use electricity as their primary source of energy, however, they also use a backup source of energy, such as gasoline, methanol or ethanol. Solar-powered vehicles are electric vehicles that use photovoltaic cells (cells that convert solar energy to electricity) rather than utility-supplied electricity to recharge the batteries. These concepts are discussed.

  19. Positive impact of electric vehicle and ngv on environment

    International Nuclear Information System (INIS)

    Shahidul I Khan; Kannan, K.S.; Md Shah Majid

    1999-01-01

    Electric Vehicle uses electricity from batteries as fuel and is environment friendly with zero emission. The occurrence of haze in 1997 in Malaysia and neighbouring countries has called for new studies about motor vehicle emission as it aggravates the problem. In big cities like Kuala Lumpur, Penang and Johor Bahru where it is estimated that over 300,000 vehicles enter the city everyday, smoke pollution from vehicles is identified as the major contributor to air quality. One of the solutions to air pollution problem could be the use of Electric Vehicles (EV) and Natural Gas for Vehicle (NGV). The NGV uses compressed natural gas mainly methane, is lead free and clean burning with low emission. The electric vehicles use batteries as power source. These batteries are charged off-peak hour, specifically after mid-night when the electric load curve has its least demand period. The number of electric vehicles and NGV in future years is calculated considering the penetration level. The reduction in pollution is estimated considering the number of automobiles replaced by electric vehicles and NGV. Finally, it is concluded that EV and NGV could be the ultimate solution for pollution control and could improve the environment specifically that of congested cities of Malaysia. (Author)

  20. Evolution of periodicity in periodical cicadas.

    Science.gov (United States)

    Ito, Hiromu; Kakishima, Satoshi; Uehara, Takashi; Morita, Satoru; Koyama, Takuya; Sota, Teiji; Cooley, John R; Yoshimura, Jin

    2015-09-14

    Periodical cicadas (Magicicada spp.) in the USA are famous for their unique prime-numbered life cycles of 13 and 17 years and their nearly perfectly synchronized mass emergences. Because almost all known species of cicada are non-periodical, periodicity is assumed to be a derived state. A leading hypothesis for the evolution of periodicity in Magicicada implicates the decline in average temperature during glacial periods. During the evolution of periodicity, the determinant of maturation in ancestral cicadas is hypothesized to have switched from size dependence to time (period) dependence. The selection for the prime-numbered cycles should have taken place only after the fixation of periodicity. Here, we build an individual-based model of cicadas under conditions of climatic cooling to explore the fixation of periodicity. In our model, under cold environments, extremely long juvenile stages lead to extremely low adult densities, limiting mating opportunities and favouring the evolution of synchronized emergence. Our results indicate that these changes, which were triggered by glacial cooling, could have led to the fixation of periodicity in the non-periodical ancestors.

  1. Diagnosis of electric equipment at the Dalat Nuclear Research Reactor

    International Nuclear Information System (INIS)

    Nguyen Truong Sinh

    1999-01-01

    The Dalat Nuclear Research Reactor (DNRR) is a pool type of its kind in the world: Soviet-designed core and control system harmoniously integrated into the left-over infrastructure of the former American-made TRIGA MARK II reactor, which includes the reactor tank and shielding, graphite reflector, beam tubes and thermal column. The reactor is mainly used for radioisotope and radiopharmaceutical production, elemental analysis using neutron activation techniques, neutron beam exploitation, silicon doping, and reactor physics experimentation. For safe operation of the reactor maintenance work has been carried out for the reactor control and instrumentation, reactor cooling, ventilation, radiomonitoring, mechanical, normal electric supply systems as well as emergency electric diesel generators and the water treatment station. Technical management of the reactor includes periodical maintenance as required by technical specifications, training, re-training and control of knowledge for reactor staff. During recent years, periodic preventive maintenance (PPM) has been carried out for the electric machines of the technological systems. (author)

  2. Electric shock and electrical fire specialty

    International Nuclear Information System (INIS)

    2011-02-01

    This book deals with electric shock and electrical fire, which is made up seven chapters. It describes of special measurement for electric shock and electrical fire. It mentions concretely about electrical fire analysis and precautionary measurement, electrical shock analysis cases, occurrence of static electricity and measurement, gas accident, analysis of equipment accident and precautionary measurement. The book is published to educate the measurement on electric shock and electrical fire by electrical safety technology education center in Korea Electrical Safety Corporation.

  3. Predicting the Response of Electricity Load to Climate Change

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, Patrick [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Colman, Jesse [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kalendra, Eric [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-07-28

    Our purpose is to develop a methodology to quantify the impact of climate change on electric loads in the United States. We perform simple linear regression, assisted by geospatial smoothing, on paired temperature and load time-series to estimate the heating- and coolinginduced sensitivity to temperature across 300 transmission zones and 16 seasonal and diurnal time periods. The estimated load sensitivities can be coupled with climate scenarios to quantify the potential impact of climate change on load, with a primary application being long-term electricity scenarios. The method allows regional and seasonal differences in climate and load response to be reflected in the electricity scenarios. While the immediate product of this analysis was designed to mesh with the spatial and temporal resolution of a specific electricity model to enable climate change scenarios and analysis with that model, we also propose that the process could be applied for other models and purposes.

  4. Water-Constrained Electric Sector Capacity Expansion Modeling Under Climate Change Scenarios

    Science.gov (United States)

    Cohen, S. M.; Macknick, J.; Miara, A.; Vorosmarty, C. J.; Averyt, K.; Meldrum, J.; Corsi, F.; Prousevitch, A.; Rangwala, I.

    2015-12-01

    Over 80% of U.S. electricity generation uses a thermoelectric process, which requires significant quantities of water for power plant cooling. This water requirement exposes the electric sector to vulnerabilities related to shifts in water availability driven by climate change as well as reductions in power plant efficiencies. Electricity demand is also sensitive to climate change, which in most of the United States leads to warming temperatures that increase total cooling-degree days. The resulting demand increase is typically greater for peak demand periods. This work examines the sensitivity of the development and operations of the U.S. electric sector to the impacts of climate change using an electric sector capacity expansion model that endogenously represents seasonal and local water resource availability as well as climate impacts on water availability, electricity demand, and electricity system performance. Capacity expansion portfolios and water resource implications from 2010 to 2050 are shown at high spatial resolution under a series of climate scenarios. Results demonstrate the importance of water availability for future electric sector capacity planning and operations, especially under more extreme hotter and drier climate scenarios. In addition, region-specific changes in electricity demand and water resources require region-specific responses that depend on local renewable resource availability and electricity market conditions. Climate change and the associated impacts on water availability and temperature can affect the types of power plants that are built, their location, and their impact on regional water resources.

  5. Electric Substations

    Data.gov (United States)

    Department of Homeland Security — Substations. Substations are facilities and equipment that switch, transform, or regulate electric voltage. The Substations feature class includes taps, a location...

  6. Atmospheric electricity

    CERN Document Server

    Chalmers, J Alan

    1957-01-01

    Atmospheric Electricity brings together numerous studies on various aspects of atmospheric electricity. This book is composed of 13 chapters that cover the main problems in the field, including the maintenance of the negative charge on the earth and the origin of the charges in thunderstorms. After a brief overview of the historical developments of atmospheric electricity, this book goes on dealing with the general principles, results, methods, and the MKS system of the field. The succeeding chapters are devoted to some aspects of electricity in the atmosphere, such as the occurrence and d

  7. A COMPARATIVE ANALYSIS OF ENERGY MANAGEMENT STRATEGIES FOR ELECTRIC VEHICLES

    OpenAIRE

    ÇAKAR, Fahri; YILMAZ, Musa; ASKER, Mehmet Emin

    2016-01-01

    In next two decade duration the electric car will participate a significant role in auto marketing. The electrical car use electric that is supported by current electrical network. Indeed the current electrical network cannot support the hole system in specific time in the case of loading electric car to it that will increase the demand in that specific time duration. To support the electric car energy requirement you have to manage both energy generation and energy consumption. The solution ...

  8. The Newnes guide to home electrics

    CERN Document Server

    Burdett, Geoffrey

    2013-01-01

    Home Electrics, Second Edition provides a do-it-yourself (DIY) guide to residential electric systems. The book is comprised of 15 chapters that cover the different aspects of home electrics. The topics covered in the text include electrical installation, rewiring, power circuits, electrical hardware, electrical repairs, tools, and safety. The book also discusses a specific area or function of home electronics, such as lighting system, lamps, electric cookers, and outdoor electrical extension. The book will be of great use to individuals interested in learning how to conduct proper home electri

  9. Electric machine

    Science.gov (United States)

    El-Refaie, Ayman Mohamed Fawzi [Niskayuna, NY; Reddy, Patel Bhageerath [Madison, WI

    2012-07-17

    An interior permanent magnet electric machine is disclosed. The interior permanent magnet electric machine comprises a rotor comprising a plurality of radially placed magnets each having a proximal end and a distal end, wherein each magnet comprises a plurality of magnetic segments and at least one magnetic segment towards the distal end comprises a high resistivity magnetic material.

  10. Teaching Electricity.

    Science.gov (United States)

    Iona, Mario

    1982-01-01

    To clarify the meaning of electrical terms, a chart is used to compare electrical concepts and relationships with a more easily visualized system in which water flows from a hilltop reservoir through a pipe to drive a mill at the bottom of the hill. A diagram accompanies the chart. (Author/SK)

  11. Ontario electricity bill review

    International Nuclear Information System (INIS)

    O'Neill, G.

    2003-01-01

    Findings of an independent review of charges to electricity bills and recommendations to assist in the development of a standard, province-wide residential electricity bill for Ontario are discussed. The review was requested by the province's Minister of Energy in an effort to dispel growing confusion about the variations in customer billing practices used by the province's 90+ local distribution companies. Key recommendations and findings were as follows: (1)Consumer bill formats issued by local distribution companies should be more consumer-friendly, adhere to minimum design standards, adapt uniform terminology and common line charges; (2) charges on customer bills should be grouped into four standard line items, with full details available to customers: the four line items should be a basic service charge, a charge for delivering electricity to the customer, a charge for the electricity itself, and a separate charge for retiring the outstanding debt of the former Ontario Hydro; (3) bills should take advantage of opportunities for promoting province-wide energy conservation, such as encouraging the long-term use of interval meters, presenting historical consumption data on residential bills on a period-to-period basis, and education and communications initiatives. Details of the recommendations, including the calculation of the fixed and variable components of usage charges, an explanation of the concept of electricity system loss adjustments, a method for phasing in the recommendations, and the anticipated benefits to consumers are provided

  12. The Relationship between Residential Electricity Consumption and Income: A Piecewise Linear Model with Panel Data

    Directory of Open Access Journals (Sweden)

    Yanan Liu

    2016-10-01

    Full Text Available There are many uncertainties and risks in residential electricity consumption associated with economic development. Knowledge of the relationship between residential electricity consumption and its key determinant—income—is important to the sustainable development of the electric power industry. Using panel data from 30 provinces for the 1995–2012 period, this study investigates how residential electricity consumption changes as incomes increase in China. Previous studies typically used linear or quadratic double-logarithmic models imposing ex ante restrictions on the indistinct relationship between residential electricity consumption and income. Contrary to those models, we employed a reduced piecewise linear model that is self-adaptive and highly flexible and circumvents the problem of “prior restrictions”. Robust tests of different segment specifications and regression methods are performed to ensure the validity of the research. The results provide strong evidence that the income elasticity was approximately one, and it remained stable throughout the estimation period. The income threshold at which residential electricity consumption automatically remains stable or slows has not been reached. To ensure the sustainable development of the electric power industry, introducing higher energy efficiency standards for electrical appliances and improving income levels are vital. Government should also emphasize electricity conservation in the industrial sector rather than in residential sector.

  13. The potential of at-home prediction of the formation of urolithiasis by simple multi-frequency electrical conductivity of the urine and the comparison of its performance with urine ion-related indices, color and specific gravity.

    Science.gov (United States)

    Silverio, Angelito A; Chung, Wen-Yaw; Cheng, Cheanyeh; Wang, Hai-Lung; Kung, Chien-Min; Chen, Jun; Tsai, Vincent F S

    2016-04-01

    It is important to control daily diet, water intake and life style as well as monitor the quality of urine for urolithiasis prevention. For decades, many ion-related indices have been developed for predicting the formation of urinary stones or urolithiasis, such as EQUILs, relative supersaturation (RSS), Tiselius indices (TI), Robertson risk factor algorithms (RRFA) and more recently, the Bonn risk index. However, they mostly demand robust laboratory analysis, are work-intensive, and even require complex computational programs to get the concentration patterns of several urine analytes. A simple and fast platform for measuring multi-frequency electrical conductivity (MFEC) of morning spot urine (random urine) to predict the onset of urolithiasis was implemented in this study. The performance thereof was compared to ion-related indices, urine color and specific gravity. The concentrations of relevant ions, color, specific gravity (SG) and MFEC (MFEC tested at 1, 10, 100, 5001 KHz and 1 MHz) of 80 random urine samples were examined after collection. Then, the urine samples were stored at 4 °C for 24 h to determine whether sedimentation would occur or not. Ion-activity product index of calcium oxalate (AP(CaOx) EQ2) was calculated. The correlation between AP(CaOx) EQ2, urine color, SG and MFEC were analyzed. AP(CaOx) EQ2, urine color and MFEC (at 5 frequencies) all demonstrated good prediction (p = 0.01, 0.01, 0.01, respectively) for stone formation. The positive correlation between AP(CaOx) EQ2 and MFEC is also significant (p = 0.01). MFEC provides a good metric for predicting the onset of urolithiasis, which is comparable to conventional ion-related indices and urine color. This technology can be implemented with much ease for objectively monitoring the quality of urine at points-of-care or at home.

  14. Overview Of Planning Direction Of Nuclear Power Development In Vietnam In The Period Up To 2030

    International Nuclear Information System (INIS)

    Ta Van Huong; Tran Hong Nguyen

    2011-01-01

    Research for peaceful application of nuclear energy, in general, and in particular, for construction of nuclear power plants (NPP) in Vietnam is urgent for social-economic development and for meeting the increasing national electrical demand in future. The expected plan for developing NPPs in Vietnam is defined in the Planning Direction of Nuclear Power Development in Vietnam in the period up to 2030. In according to which, NPPs have been planned in selected sites by the period depends on the detailed conditions of each site, as well as on specification of the national electrical grid. The present report reviews the highlights of this Planning Direction of Nuclear Power Development in Vietnam in the period up to 2030. (author)

  15. Political determinants of electricity provision in small island developing states

    International Nuclear Information System (INIS)

    Boräng, Frida; Jagers, Sverker C.; Povitkina, Marina

    2016-01-01

    This paper approaches provision of affordable and reliable electricity in Small Island Developing States (SIDS) as a case of public good provision. It aims to contribute to our understanding of how regime type and the quality of implementing institutions within political systems affect the prerequisites for successful electrification in SIDS. More specifically, we analyse the independent and interdependent effects of level of democracy and control of corruption on per capita household electricity consumption in SIDS, using data from 34 SIDS over the period 1996–2009. The results show that although the independent effects of level of democracy and control of corruption are sensitive to model specification, these two factors do have an interdependent impact on per capita household electricity consumption: democratization has positive effects on provision of electricity to the general population only when there is a certain level of corruption control in place. The results imply a) that it is important for policy actors to acknowledge the interaction between regime type and the quality of implementing institutions, and b) when planning electrification projects in SIDS, it is necessary to have information about the social and political context in order to design the most effective projects. - Highlights: • Effects of political institutions on household electricity consumption in SIDS. • Electrification is seen as an example of public good provision. • Democracy has a positive impact on electricity consumption when corruption is low. • Electrification projects can gain from being sensitive to institutional context.

  16. Change in Nuclear Electric

    International Nuclear Information System (INIS)

    Smart, D.

    1996-01-01

    Activities of Nuclear Electric company (Great Britain) in 1990-1995, aimed at privatization of certain NPPs and services, are considered. The company introduced commercial principles of work and control in all areas of expenditures. Great attention was paid to the work with personnel according to the program Investments in Personnel. All these initiatives resulted in increase in the total electricity production by 39% during the period of time under consideration in the 100% increase in the output per man/hour. This made it possible for the government to introduce its proposal on privatization of greater part of companies

  17. Apollo Lunar Module Electrical Power System Overview

    Science.gov (United States)

    Interbartolo, Michael

    2009-01-01

    Objectives include: a) Describe LM Electrical System original specifications; b) Describe the decision to change from fuel cells to batteries and other changes; c) Describe the Electrical system; and d) Describe the Apollo 13 failure from the LM perspective.

  18. Electric drives

    Energy Technology Data Exchange (ETDEWEB)

    1986-10-01

    Several electric vehicles have been tested in long-term tests, i.e. an electric passenger car (maximum speed 115 km/h) and several busses for use in pedestrians' zones, spas, airports, natural reserves, and urban transportation (DUO busses). The ICE high-speed train is discussed in some detail, i.e. its aeroacoustic and aerodynamic design, running gear, computer-controlled drives and brakes, diagnostic systems, and electrical equipment. The Berlin Maglev system is mentioned as well as current inverters in rail vehicles. (HWJ).

  19. Electricity regulation and economic growth

    OpenAIRE

    Costa, M. Teresa (Maria Teresa), 1951-; Garcia-Quevedo, Jose; Trujillo-Baute, Elisa

    2018-01-01

    The main objective of this paper is to analyse the effect of electricity regulation on economic growth. Although the relationship between electricity consumption and economic growth has been extensively analysed in the empirical literature, this framework has not been used to estimate the effect of electricity regulation on economic growth. Understanding this effect is essential for the assessment of regulatory policy. Specifically, we assess the effects of two major areas of regulation, rene...

  20. Electric utilities in Illinois

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-01

    Although the conference dealt specifically with concerns of the electric utilities in Illinois, the issues were dealt with in the national context as well. A separate abstract was prepared for each of the 5 sections of this proceeding. A total of 25 papers were presented. Section titles are: Forecasting, Planning and Siting, Reliability, Rates and Financing, and Future Developments.

  1. The financial and accounting implications of the privatization of the regional electricity companies in the UK

    International Nuclear Information System (INIS)

    Thomson, L.

    1993-01-01

    This paper reviews some of the financial and accounting implications of the privatization of the electricity distribution and supply sector in England and Wales, specifically the transformation of the Electricity Area Boards into the 12 Regional Electricity Companies (RECs). It considers the factors influencing the setting of post-privatization price control factors; the capital restructuring of the RECs; the valuation placed by the Secretary of State for Energy on each company at flotation, and market reaction to this as shown in subsequent changes in share price; and changes in the information provided in the RECs' accounts over the privatization period. (Author)

  2. Electricity derivatives

    CERN Document Server

    Aïd, René

    2015-01-01

    Offering a concise but complete survey of the common features of the microstructure of electricity markets, this book describes the state of the art in the different proposed electricity price models for pricing derivatives and in the numerical methods used to price and hedge the most prominent derivatives in electricity markets, namely power plants and swings. The mathematical content of the book has intentionally been made light in order to concentrate on the main subject matter, avoiding fastidious computations. Wherever possible, the models are illustrated by diagrams. The book should allow prospective researchers in the field of electricity derivatives to focus on the actual difficulties associated with the subject. It should also offer a brief but exhaustive overview of the latest techniques used by financial engineers in energy utilities and energy trading desks.

  3. Electric empire

    International Nuclear Information System (INIS)

    McKay, Paul

    1983-01-01

    The author discusses the economic and political aspects of Ontario Hydro, a provincial crown corporation. He also deals with nuclear safety of the CANDU reactors and the ecological effects of electric power supply. Alternate sources of energy are also mentioned

  4. Electrical Conductivity.

    Science.gov (United States)

    Hershey, David R.; Sand, Susan

    1993-01-01

    Explains how electrical conductivity (EC) can be used to measure ion concentration in solutions. Describes instrumentation for the measurement, temperature dependence and EC, and the EC of common substances. (PR)

  5. Electric theory

    International Nuclear Information System (INIS)

    Gong, Ha Seong

    2006-02-01

    This book explains electric theory which is divided into four chapters. The first chapter includes electricity and material, electric field, capacitance, magnetic field and electromagnetic force, inductance. The second chapter mentions electronic circuit analysis, electric resistance,heating and power, chemical activity on current and battery with electrolysis. The third chapter deals with an alternating current circuit about the basics of an AC circuit, operating of resistance, inductance and capacitance, series circuit and parallel circuit of PLC, an alternating current circuit, Three-phase Alternating current, two terminal pair network and voltage and current of non-linearity circuit. The last explains transient phenomena of RC series circuit, RL series circuit, transient phenomena of an alternating current circuit and transient phenomena of RLC series circuit.

  6. Electrical injury

    Science.gov (United States)

    ... RS, Gausche-Hill M, eds. Rosen's Emergency Medicine: Concepts and Clinical Practice. 9th ed. Philadelphia, PA: Elsevier; 2018:chap 134. Price LA, Loiacono LA. Electrical and lightning injury. In: Cameron JL, Cameron AM, eds. Current Surgical ...

  7. Periodicity, the Canon and Sport

    Directory of Open Access Journals (Sweden)

    Thomas F. Scanlon

    2015-10-01

    Full Text Available The topic according to this title is admittedly a broad one, embracing two very general concepts of time and of the cultural valuation of artistic products. Both phenomena are, in the present view, largely constructed by their contemporary cultures, and given authority to a great extent from the prestige of the past. The antiquity of tradition brings with it a certain cachet. Even though there may be peripheral debates in any given society which question the specifics of periodization or canonicity, individuals generally accept the consensus designation of a sequence of historical periods and they accept a list of highly valued artistic works as canonical or authoritative. We will first examine some of the processes of periodization and of canon-formation, after which we will discuss some specific examples of how these processes have worked in the sport of two ancient cultures, namely Greece and Mesoamerica.

  8. Electricity and the Canadian economy

    International Nuclear Information System (INIS)

    Melvin, J.G.

    1981-10-01

    Electricity consumption in Canada bore a fixed relationship to real Gross National Product (GNP) throughout the period 1961 to 1979, with an annual growth rate equal to 1.275 times GNP growth rate. Data for the Province of Ontario reveal a similar correlation, but suggest an accelerated demand relative to Gross Provincial Product since 1973, perhaps due to cost-induced substitution of electricity for oil. Electricity demand growth and economic expansion are seen to be mutually reinforcing. High and low values are estimated for future growth rates of population and per-capita GNP. Combined with appropriate rates of oil substitution, these yield projections of electricity demand growth to the end of the century. Electricity demand is likely to grow at close to the traditional rate of 7% per annum unless economic stagnation continues, population growth is minimal, and electricity fails to substitute for oil on a significant scale

  9. Rural Electricity and Isolated Systems

    International Nuclear Information System (INIS)

    Ruiz, Otto; Solorzano, Benjamin

    2000-01-01

    The paper describes the impact of the cost of investment, operation and trading of rural electricity and discuss cost-benefit analysis. This evaluation covers a three different periods: before 1990, the period 1990-1996 and 1997-1999. Also the trends of demand and supply of energy are presented

  10. Privatising British electricity

    International Nuclear Information System (INIS)

    Holmes, A.

    1992-01-01

    The privatisation of the British electricity industry was intended to be the most radical change made to a European power system in the post-war period. It was of an experimental nature, imposing on electricity a way of operating which has no equivalent anywhere in the world. This report shows, however, that in the long run-up to privatisation, a number of factors combined to pull the plan far from its original aims and to produce a hybrid system which has caused many new difficulties without establishing a fully commercial market. The original ideas behind the new system - most notably the establishment of a fully competitive commercial system - have not been fulfilled. Many of them were wholly impractical. The problems of establishing a competitive market in electricity were never properly addressed until the planning for the new system was well under way. (author)

  11. Electric cars as mobile power storage systems

    International Nuclear Information System (INIS)

    Herzog, B.

    2010-01-01

    This article discusses the use of electric cars as a means of optimising the use of renewable energy sources. Charging the cars' batteries during periods when cheap electricity prices prevail and then using excess capacity to supply the mains with electricity during periods of peak demand is discussed. The possible use of wind for power generation is discussed and a system proposed by a leading supplier of electrical apparatus and systems is examined. Two examples of electric cars and associated power chains are looked at and tests in everyday practice are described

  12. Deploying Electric Vehicles and Electric Vehicle Supply Equipment: Tiger Teams Offer Project Assistance for Federal Fleets

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-01-02

    To assist federal agencies with the transition to plug-in electric vehicles (PEVs), including battery electric vehicles (BEVs) and plug-in hybrid electric vehicles (PHEVs), FEMP offers technical guidance on electric vehicle supply equipment (EVSE) installations and site-specific planning through partnerships with the National Renewable Energy Laboratory’s EVSE Tiger Teams.

  13. Electricity Use in the Pacific Northwest: Utility Historical Sales by Sector, 1989 and Preceding Years.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1990-06-01

    This report officially releases the compilation of regional 1989 retail customer sector sales data by the Bonneville Power Administration. This report is intended to enable detailed examination of annual regional electricity consumption. It gives statistics covering the time period 1970--1989, and also provides observations based on statistics covering the 1983--1989 time period. The electricity use report is the only information source that provides data obtained from each utility in the region based on the amount of electricity they sell to consumers annually. Data is provided on each retail customer sector: residential, commercial, industrial, direct-service industrial, and irrigation. The data specifically supports forecasting activities, rate development, conservation and market assessments, and conservation and market program development and delivery. All of these activities require a detailed look at electricity use. 25 figs., 34 tabs.

  14. The electric motor handbook

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, R.W.; Feltham, P. (eds.)

    2004-05-01

    This handbook outlines the important role that electric motors play in modern society. It covers the field of motor applications from various motor types to their use and repair. It also presents practical applications of electric motors and methods on motor efficiency. More than half of all electricity generated, and 75 per cent of all industrial electricity consumption is consumed by electric motors. Electrical personnel must be aware of all factors involved in electric motors in order to choose and apply the appropriate size of electric motor. These factors include efficiency, sizing and proper application. The efficient use and maximum life expectancy of electric motors depends on proper motor protection, control and maintenance. This handbook includes articles from leading experts on electric motors in modern electrical systems. The content includes: design considerations; proper electric motor sizing techniques; optimal electric motor application; electric motor protection technology; electric motor control principles; electric motor maintenance and troubleshooting; induction electric motors; electric motor bearing currents; electric motor bearing lubrication; electromagnetism; electric motor enclosures; electric motor testing; electric motor repair; DC electric motor; electric motor starters; electric motor brushes; industrial electric motors; electric motor diagrams; AC electric motors; electric motor wiring; electric motor service; electric motor rewinding; electric motor winding; diagram of electric motor wiring; electric motor kit; and, troubleshooting electric motors. A directory of motor manufacturers and suppliers was also included. refs., tabs., figs.

  15. Electrical-Generation Scenarios for China

    Energy Technology Data Exchange (ETDEWEB)

    Kypreos, S.; Krakowski, R.A.

    2002-03-01

    The China Energy Technology Program (CETP) used both optimizing and simulation energy- economic-environmental (E3) models to assess tradeoffs in the electricity-generation sector for a range of fuel, transport, generation, and distribution options. The CETP is composed of a range of technical tasks or activities, including Energy Economics Modeling (EEM, optimizations), Electric Sector Simulation (ESS, simulations), Life Cycle Analyses (LCA, externalization) of energy systems, and Multi-Criteria Decision Analyses (MCDA, integration). The scope of CETP is limited to one province (Shandong), to one economic sector (electricity), and to one energy sector (electricity). This document describes the methods, approaches, limitations, sample results, and future/needed work for the EEM ( optimization-based modeling) task that supports the overall goal of CETP. An important tool used by the EEM task is based on a Linear Programming (LP) optimization model that considers 17 electricity-generation technologies utilizing 14 fuel forms (type, composition, source) in a 7-region transportation model of China's electricity demand and supply system over the period 2000-2030; Shandong is one of the seven regions modeled. The China Regional Electricity Trade Model (CRETM) is used to examine a set of energy-environment-economy E3-driven scenarios to quantify related policy implications. The development of electricity production mixes that are optimized under realistically E3 constraints is determined through regional demands for electricity that respond to exogenous assumptions on income (GDP) and electricity prices through respective time-dependent elasticities. Constraints are applied to fuel prices, transportation limits, resource availability, introduction (penetration) rates of specific technology, and (where applicable) to local, regional, and countrywide emission rates of CO{sub 2}, SO{sub 2} and NO{sub x}. Importantly, future inter- regional energy flows are optimized with

  16. RENEWABLE ENERGY SOURCES IN ELECTRIC-POWER IN-DUSTRY OF BELARUS

    Directory of Open Access Journals (Sweden)

    M. M. Oleshkevich

    2014-01-01

    Full Text Available The paper investigates technical and economic indices (specific capital inputs, construction period, pay-off period, possible economically substantiated generation of electric power of electric power plants using renewable energy sources under climatic conditions ofBelarus. The indices have been compared with the data of nuclear power engineering. The most efficient directions are wind and biomass power engineering. In accordance with its technical and economic and ecological indices the biomass power engineering is more profitable than nuclear, hydro- and solar power engineering.

  17. Swiss electricity statistics 2008

    International Nuclear Information System (INIS)

    2009-06-01

    This comprehensive report made by the Swiss Federal Office of Energy (SFOE) presents the statistics for 2008 on electricity production and usage in Switzerland for the year 2008. First of all, an overview of Switzerland's electricity supply in 2008 is presented. Details are noted of the proportions generated by different sources including nuclear, hydro-power, storage schemes and thermal power stations as well as energy transfer with neighbouring countries. A second chapter takes a look at the balance of imports and exports with illustrative flow diagrams along with tables for total figures from 1950 through to 2008. For the summer and winter periods, figures from 1995 to 2008 are presented. The third chapter examines the production of electricity in the various types of power stations and the developments over the years 1950 to 2008, whereby, for example, statistics on regional generation and power station type are looked at. The fourth chapter looks at electricity consumption in various sectors from 1984 to 2008 and compares the figures with international data. The fifth chapter looks at generation, consumption and loading on particular days and chapter six considers energy exchange with Switzerland's neighbours. Chapter seven takes a look at possibilities for extending generation facilities in the period up to 2015

  18. Swiss electricity statistics 2005

    International Nuclear Information System (INIS)

    2006-01-01

    This comprehensive report made by the Swiss Federal Office of Energy (SFOE) presents the statistics for 2005 on electricity production and usage in Switzerland for the year 2005. First of all, an overview of Switzerland's electricity supply in 2005 is presented. Details are noted of the proportions generated by different sources including nuclear, hydro-power, storage schemes and thermal power stations as well as energy transfer with neighbouring countries. A second chapter takes a look at the balance of imports and exports with illustrative flow diagrams along with tables for total figures from 1950 through to 2005. For the summer and winter periods, figures from 1995 to 2005 are presented. The third chapter examines the production of electricity in the various types of power stations and the developments over the years 1950 to 2005, whereby, for example, statistics on regional generation and power station type are looked at. The fourth chapter looks at electricity consumption in various sectors from 1983 to 2005 and compares the figures with international data. The fifth chapter looks at generation, consumption and loading on particular days and chapter six considers energy exchange with Switzerland's neighbours. Chapter seven takes a look at possibilities for extending generation facilities in the period up to 2012

  19. Swiss electricity statistics 2006

    International Nuclear Information System (INIS)

    2007-01-01

    This comprehensive report made by the Swiss Federal Office of Energy (SFOE) presents the statistics on electricity production and usage in Switzerland for the year 2006. First of all, an overview of Switzerland's electricity supply in 2006 is presented. Details are noted of the amounts generated by different sources including nuclear, hydro-power, storage schemes and thermal power stations as well as energy transfer with neighbouring countries. A second chapter takes a look at the balance of imports and exports with illustrative flow diagrams along with tables for total figures from 1950 through to 2006. For the summer and winter periods, figures from 1995 to 2006 are presented. The third chapter examines the production of electricity in the various types of power stations and the developments over the years 1950 to 2006, whereby, for example, statistics on regional generation and power station type are looked at. The fourth chapter looks at electricity consumption in various sectors from 1983 to 2006 and compares the figures with international data. The fifth chapter looks at generation, consumption and loading on particular, selected days and chapter six considers energy exchange with Switzerland's neighbours. Chapter seven takes a look at possibilities for extending generation facilities in the period up to 2013

  20. Solar energy thermally powered electrical generating system

    Science.gov (United States)

    Owens, William R. (Inventor)

    1989-01-01

    A thermally powered electrical generating system for use in a space vehicle is disclosed. The rate of storage in a thermal energy storage medium is controlled by varying the rate of generation and dissipation of electrical energy in a thermally powered electrical generating system which is powered from heat stored in the thermal energy storage medium without exceeding a maximum quantity of heat. A control system (10) varies the rate at which electrical energy is generated by the electrical generating system and the rate at which electrical energy is consumed by a variable parasitic electrical load to cause storage of an amount of thermal energy in the thermal energy storage system at the end of a period of insolation which is sufficient to satisfy the scheduled demand for electrical power to be generated during the next period of eclipse. The control system is based upon Kalman filter theory.

  1. Flinders University Electric Vehicle Project

    Science.gov (United States)

    Atkinson, D. A.

    1973-01-01

    Outlines the specifications and principles involved in the operation of an electric car developed by the Institute of Solar and Electochemical Energy Conversion at Flinders University in South Australia. (JR)

  2. Electric motor handbook

    CERN Document Server

    Chalmers, B J

    2013-01-01

    Electric Motor Handbook aims to give practical knowledge in a wide range of capacities such as plant design, equipment specification, commissioning, operation and maintenance. The book covers topics such as the modeling of steady-state motor performance; polyphase induction, synchronous, and a.c. commutator motors; ambient conditions, enclosures, cooling and loss dissipation; and electrical supply systems and motor drives. Also covered are topics such as variable-speed drives and motor control; materials and motor components; insulation types, systems, and techniques; and the installation, sit

  3. 10 CFR 603.1295 - Periodic audit.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Periodic audit. 603.1295 Section 603.1295 Energy... Used in this Part § 603.1295 Periodic audit. An audit of a participant, performed at an agreed-upon... an audit may cover. A periodic audit of a participant differs from an award-specific audit of an...

  4. The Periodic Pyramid

    Science.gov (United States)

    Hennigan, Jennifer N.; Grubbs, W. Tandy

    2013-01-01

    The chemical elements present in the modern periodic table are arranged in terms of atomic numbers and chemical periodicity. Periodicity arises from quantum mechanical limitations on how many electrons can occupy various shells and subshells of an atom. The shell model of the atom predicts that a maximum of 2, 8, 18, and 32 electrons can occupy…

  5. Book Reviews in Periodicals.

    Science.gov (United States)

    Ettelt, Harold J.

    All recent issues of periodicals found which contain indexed book reviews are listed in this compilation from Drake Memorial Library at the New York State University at Brockport. The periodicals are listed by 29 subject headings in this informal guide designed to be used at Drake Library. The number of reviews in the periodical in a recent year…

  6. Greengrid Electric

    International Nuclear Information System (INIS)

    Argue, D.

    1998-01-01

    This presentation focused on what customers want from a competitive electricity market and what motivates customers to choose a renewable energy product and service. Greengrid Electric, a subsidiary of Enershare Technology Corp., intends to provide the green electricity that they believe customers have wanted for some time. Enershare and Greengrid have been active participants in the electricity restructuring process in Ontario, and have provided input to the Market Design Committee. Once licensed as a retailer, Greengrid intends to be the major provider of green electricity in Ontario. The company will supply a 100 per cent renewable energy product to their wholesale and retail customers. The company is confident that there is a significant niche market in Ontario for selling a green product that has a blend of wind, small hydro (run-of-river or existing dam), solar, and for energy produced from capturing methane gas from municipal landfill sites. Company officials are confident that customers will be willing to pay a premium price for energy if their purchases will lead to environmental improvement

  7. The electricity market 2002

    International Nuclear Information System (INIS)

    2002-01-01

    taxes. The price of electricity dropped between 1997 and 2000, but began rising again to all electricity customers during 2000 and 2001. During the same period, the network charges remained largely unchanged, while the tax on electricity increased substantially. This led to an increase in the total cost to domestic customers, whereas the cost to industrial customers, who are exempt from taxes, is lower. The reform has enabled customers to choose freely the supplier from whom they want to buy their electricity. An opinion poll shows that most customers know that they can choose their supplier, and 37 % have acted on this by changing to a different supplier or negotiating their electricity price. The market concentration has increased in recent years since the dominating companies in Nordic countries have bought shares in competing companies on the Nordic market. The power companies and electricity trading companies are being developed towards bigger and more integrated energy companies, with operations in several countries. In recent years, the former surplus generation capacity in Sweden has been reduced. The oil-fired condensing power stations that were previously used in Sweden as reserve capacity have been decommissioned, and the first reactor in Barsebaeck was shut down. Svenska Kraftnaet, the Swedish grid utility, purchased a power reserve before the winter of 2000/2001 in order to strengthen the power balance during consumption peaks. During the autumn of 2001, the Government also entrusted Svenska Kraftnaet with the task of safe-guarding electricity generation capacity during very cold weather. This was to be done by purchasing reserve power capacity. The assignment resulted in additional power generation capacity consisting of previously decommissioned power generation plants and companies that were prepared to reduce their power consumption voluntarily. The procurement of reserve capacity is a temporary transitional measure. In the Government assignment

  8. Change in consumer sensitivity to electricity prices in response to retail deregulation: A panel empirical analysis of the residential demand for electricity in the United States

    International Nuclear Information System (INIS)

    Nakajima, Tadahiro; Hamori, Shigeyuki

    2010-01-01

    About ten years have passed since the deregulation of the U.S. retail electricity market, and it is now generally accepted that the available data is adequate to quantitatively assess and compare conditions before and after deregulation. This study, therefore, estimates the changes in price elasticity in the residential electricity market to examine the changes, if any, in household sensitivity (as a result of retail electricity market deregulation policies) to residential electricity rates. Specifically, six types of panel data are prepared, based on three cross-sections-all states (except for Alaska and Hawaii) and the District of Columbia, deregulated states, and non-deregulated states-and two time series-the period before deregulation and the period after deregulation. The panel empirical analysis techniques are used to determine whether or not the variables are stationary, and to estimate price elasticity. We find that there is no substantial difference in the price elasticity between deregulated and non-deregulated states for both periods-before deregulation and after deregulation. Thus, it can be said that the deregulation of the retail electricity market has not made consumers more sensitive to electricity rates and that retail deregulation policies are not the cause of price elasticity differences between deregulated and non-deregulated states.

  9. Change in consumer sensitivity to electricity prices in response to retail deregulation. A panel empirical analysis of the residential demand for electricity in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Tadahiro [The Kansai Electric Power Company, Incorporated, 6-16, Nakanoshima 3-chome, Kita-Ku, Osaka 530-8270 (Japan); Hamori, Shigeyuki [Faculty of Economics, Kobe University 2-1, Rokkodai, Nada-Ku, Kobe 657-8501 (Japan)

    2010-05-15

    About ten years have passed since the deregulation of the U.S. retail electricity market, and it is now generally accepted that the available data is adequate to quantitatively assess and compare conditions before and after deregulation. This study, therefore, estimates the changes in price elasticity in the residential electricity market to examine the changes, if any, in household sensitivity (as a result of retail electricity market deregulation policies) to residential electricity rates. Specifically, six types of panel data are prepared, based on three cross-sections - all states (except for Alaska and Hawaii) and the District of Columbia, deregulated states, and non-deregulated states - and two time series - the period before deregulation and the period after deregulation. The panel empirical analysis techniques are used to determine whether or not the variables are stationary, and to estimate price elasticity. We find that there is no substantial difference in the price elasticity between deregulated and non-deregulated states for both periods - before deregulation and after deregulation. Thus, it can be said that the deregulation of the retail electricity market has not made consumers more sensitive to electricity rates and that retail deregulation policies are not the cause of price elasticity differences between deregulated and non-deregulated states. (author)

  10. Detection of Periodic Beacon Loads in Electrical Distribution Substation Data

    Energy Technology Data Exchange (ETDEWEB)

    Hammerstrom, Donald J.; Guttromson, Ross T.; Lu, Ning; Boyd, Paul A.; Trudnowski, Daniel; Chassin, David P.; Bonebrake, Christopher A.; Shaw, James M.

    2006-05-31

    This research explores methods for identifying a whether a load is sending a signal to the utility SCADA system. Such a system can identify whether various loads are signialing using existing SCADA infrastructure, that is, without added, high cost communications infrastructure.

  11. electric vehicle

    Directory of Open Access Journals (Sweden)

    W. R. Lee

    1999-01-01

    Full Text Available A major problem facing battery-powered electric vehicles is in their batteries: weight and charge capacity. Thus, a battery-powered electric vehicle only has a short driving range. To travel for a longer distance, the batteries are required to be recharged frequently. In this paper, we construct a model for a battery-powered electric vehicle, in which driving strategy is to be obtained such that the total travelling time between two locations is minimized. The problem is formulated as an optimization problem with switching times and speed as decision variables. This is an unconventional optimization problem. However, by using the control parametrization enhancing technique (CPET, it is shown that this unconventional optimization is equivalent to a conventional optimal parameter selection problem. Numerical examples are solved using the proposed method.

  12. Peculiarities of electricity acquisition management

    Directory of Open Access Journals (Sweden)

    G. S. Armashova-Telnik

    2018-01-01

    Full Text Available In the current conditions for the implementation of economic guidelines for the development of the electric power industry, minimizing production costs is one of the key areas for enhancing the competitive advantages of energy enterprises. When determining a specific model for the purchase of electricity in the retail market, it is necessary to take into account the conditions of the electricity consumption regime, the marketing surcharges of the generating suppliers, the activity of the regional energy sales organizations, the price range and the scale of retail generation, the real cost of the product's withdrawal to the wholesale market. A number of provisions regarding the specifics of electricity purchase management, regulated by the Government of the Russian Federation, provide optimization of energy management processes in terms of reducing production costs, taking into account the factors of the constituent elements of the price for electricity and services of infrastructure organizations, which increases the economic efficiency of economic activities of the enterprise

  13. The electricity market 2002

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-10-01

    charges and taxes. The price of electricity dropped between 1997 and 2000, but began rising again to all electricity customers during 2000 and 2001. During the same period, the network charges remained largely unchanged, while the tax on electricity increased substantially. This led to an increase in the total cost to domestic customers, whereas the cost to industrial customers, who are exempt from taxes, is lower. The reform has enabled customers to choose freely the supplier from whom they want to buy their electricity. An opinion poll shows that most customers know that they can choose their supplier, and 37 % have acted on this by changing to a different supplier or negotiating their electricity price. The market concentration has increased in recent years since the dominating companies in Nordic countries have bought shares in competing companies on the Nordic market. The power companies and electricity trading companies are being developed towards bigger and more integrated energy companies, with operations in several countries. In recent years, the former surplus generation capacity in Sweden has been reduced. The oil-fired condensing power stations that were previously used in Sweden as reserve capacity have been decommissioned, and the first reactor in Barsebaeck was shut down. Svenska Kraftnaet, the Swedish grid utility, purchased a power reserve before the winter of 2000/2001 in order to strengthen the power balance during consumption peaks. During the autumn of 2001, the Government also entrusted Svenska Kraftnaet with the task of safe-guarding electricity generation capacity during very cold weather. This was to be done by purchasing reserve power capacity. The assignment resulted in additional power generation capacity consisting of previously decommissioned power generation plants and companies that were prepared to reduce their power consumption voluntarily. The procurement of reserve capacity is a temporary transitional measure. In the Government

  14. Reducing Electricity Demand Peaks by Scheduling Home Appliances Usage

    DEFF Research Database (Denmark)

    Rossello Busquet, Ana; Kardaras, Georgios; Iversen, Villy Bæk

    2011-01-01

    Nowadays there is a tendency to consume electricity during the same period of the day leading to demand peaks. Regular energy consumption habits lead to demand peaks at specific temporal intervals, because users consume power at the same time. In order to avoid demand peaks, users’ appliances...... should consume electricity in a more temporarily distributed way. A new methodology to schedule the usage of home appliances is proposed and analyzed in this paper. The main concept behind this approach is the aggregation of home appliances into priority classes and the definition of a maximum power...... consumption limit, which is not allowed to be exceeded during peak hours. The scenario simulated describes a modern household, where the electrical devices are classified in low and high priority groups. The high priority devices are always granted power in order to operate without temporal restrictions...

  15. Secured electrical supply at least cost: Coal, gas, nuclear, hydro

    Energy Technology Data Exchange (ETDEWEB)

    Gavor, J. [ENA Ltd., Prague (Czechoslovakia); Stary, O.; Vasicek, J. [Czech Technical Univ., Prague (Czechoslovakia)

    1995-12-01

    Electric power sector in East Central European countries finds in a difficult period. In the situation of demand stagnation, enormous investments must be realized in a very short time. Today`s decisions in the development strategy will influence the long term future of the industry. The optimal structure of the sources is one of the most important problem to be solved. Paper describes the current structure of the sources in electric power sector in the Czech Republic. The importance of coal, oil and gas, nuclear and hydro in electric power generation is compared. Taking into account the different position in the load coverage, economy of individual sources is evaluated and basic results of discounted cash flow calculations are presented. Information on specific investment programs and projects are included and further trends are estimated.

  16. Electric utility report '80

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    A collection of brief atricles describes the trends and developments in Canada's electric utilities for the 1980's. Generating stations planned or under construction are listed. The trends in technology discused at a recent Canadian Electrical Association meeting are summarized in such areas as turbine stability control, power line vibration control, system reliability, substations and transformer specifications. Developments in nuclear generation are discussed and compared on the world scale where Japan, for example, has the world's largest nuclear program. Progress on fusion is discussed. In Canada the electric utilities are receiving the support of the comprehensive nuclear R and D program of Atomic Energy of Canada Ltd. New innovations in utility technology such as street lighting contactors, superconductive fault limiters and demand profile analyzers are discussed. (T.I.)

  17. FY 2000 Development of technologies for reducing power consumption during the stand-by period. Report on the research and development results of rationally reducing power consumption by home electric appliances; 2000 nendo taikiji shohi denryoku sakugen gijutsu kaihatsu seika hokokusho. Kaden seihin no taikiji shohi denryoku no goriteki sakugen ni kansuru kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The research and development project is implemented for development of the system which automatically switches off the power source for a standing-by appliance by analyzing life pattern in each home, in order to reduce consumed power during the stand-by period. The actual service conditions of appliances in each home are surveyed through the questionnaires and recording in the diary. The analysis results indicate that as high as 70% of those who are inquired take interest in energy saving, especially high among full-time housewives. The home electric appliances considered by many to wastefully consume power are functional-keeping types, e.g., (jar pots) and (toilet seats equipped with a washing function with warm water), and heating appliances, e.g., (hot carpets). The power consumption trends at each time in each home are measured and grasped by the aid of a tool with built-in personal computer, and the algorithm for predicting use of the appliances in each home is developed for each home, based on the analysis results. The prototype energy-saving adapter and centralized controller are developed, and subjected to various tests to develop the learning/controlling algorithms. The demonstration tests of the energy-saving adapter developed confirm that power consumption during the stand-by period can be reduced at least by 10%. (NEDO)

  18. Analysis of electricity price in Danish competitive electricity market

    DEFF Research Database (Denmark)

    Hu, Weihao; Chen, Zhe; Bak-Jensen, Birgitte

    2012-01-01

    electricity markets in some ways, is chosen as the studied power system. 10 year actual data from the Danish competitive electricity market are collected and analyzed. The relationship among the electricity price (both the spot price and the regulation price), the consumption and the wind power generation...... in an electricity market is investigated in this paper. The spot price and the regulation price generally decrease when the wind power penetration in the power system increases or the consumption of the power system decreases. The statistical characteristics of the spot price and the regulation price for different...... consumption periods and wind power penetration are analyzed. Simulation results show that the findings of this paper are useful for wind power generation companies to make the optimal bidding strategy so that the imbalance cost of trading wind power on the electricity market could be reduced....

  19. Modeling of Monthly Residential and Commercial Electricity Consumption Using Nonlinear Seasonal Models—The Case of Hong Kong

    Directory of Open Access Journals (Sweden)

    Wai-Ming To

    2017-06-01

    Full Text Available Accurate modeling and forecasting monthly electricity consumption are the keys to optimizing energy management and planning. This paper examines the seasonal characteristics of electricity consumption in Hong Kong—a subtropical city with 7 million people. Using the data from January 1970 to December 2014, two novel nonlinear seasonal models for electricity consumption in the residential and commercial sectors were obtained. The models show that the city’s monthly residential and commercial electricity consumption patterns have different seasonal variations. Specifically, monthly residential electricity consumption (mainly for appliances and cooling in summer has a quadratic relationship with monthly mean air temperature, while monthly commercial electricity consumption has a linear relationship with monthly mean air temperature. The nonlinear seasonal models were used to predict residential and commercial electricity consumption for the period January 2015–December 2016. The correlations between the predicted and actual values were 0.976 for residential electricity consumption and 0.962 for commercial electricity consumption, respectively. The root mean square percentage errors for the predicted monthly residential and commercial electricity consumption were 7.0% and 6.5%, respectively. The new nonlinear seasonal models can be applied to other subtropical urban areas, and recommendations on the reduction of commercial electricity consumption are given.

  20. Electrical Rectification

    Indian Academy of Sciences (India)

    user

    bio-mimetic systems. O w ing to the saturation of the e± ciency of sil- icon devices in electronics industry, m olecular electronics has gained trem endous im petus in re- cent tim es. T heoretical predictions and experi- m ental realizations of such system s have given birth to a ... their electrical conductance property and pos-.

  1. Power losses in electrical networks depending on weather conditions

    International Nuclear Information System (INIS)

    Zhelezko, Yu. S.; Kostyushko, V. A.; Krylov, S. V.; Nikiforov, E. P.; Savchenko, O. V.; Timashova, L. V.; Solomonik, E. A.

    2005-01-01

    Specific power losses to corona and to leakage currents over overhead insulators are presented for 110 - 750-kV transmission lines with different phase design and pole types for different weather conditions. Consumption of electric energy for ice melting on conductors of various cross sections is evaluated. Meteorological data of 1372 weather stations in Russia are processed for a period of 10 years. The territory of the country is divided into 7 regions with approximately homogeneous weather conditions. Specific power losses to corona and leakage currents over overhead insulators are presented for every region

  2. Optimal control strategy design for extending all-electric driving capability of plug-in hybrid electric vehicles (PHEVs)

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, S.S [Concordia Univ., Montreal, PQ (Canada). Dept. of Electrical and Computer Engineering, P.D Ziogas Power Electronics Laboratory

    2007-07-01

    The high voltage energy storage system in plug-in hybrid electric vehicles (PHEVs) is usually a rechargeable type that service a dual purpose, notably to supplement the power delivered by the internal combustion engine, and to provide partial propulsion energy from an off-board source of electricity. The energy storage devices in electric vehicles typically improve vehicle efficiency through engine downsizing and by recapturing braking energy. However, since PHEVs have the ability to recharge their energy storage systems directly from the power grid, the periods of all-electric operation can be extended, thereby reducing the dependence on the internal combustion engine. This is particularly useful in city driving conditions. Developers of PHEV technology are faced with the challenge of choosing the appropriate energy storage battery in order to improve the all-electric drive range. In this study, control strategies were modeled for specific driving load conditions using the Advanced Vehicle Simulator (ADVISOR) software. This paper presented specific control algorithms for PHEV operation for various city driving loads. The optimal design strategy considered the improvement of critical energy storage parameters, overall drive train efficiency, and vehicle performance characteristics. Future trends in the design and development of PHEV drive trains were also presented. 13 figs.

  3. Atmospheric Electricity

    Science.gov (United States)

    Aplin, Karen; Fischer, Georg

    2018-02-01

    Electricity occurs in atmospheres across the Solar System planets and beyond, spanning spectacular lightning displays in clouds of water or dust, to more subtle effects of charge and electric fields. On Earth, lightning is likely to have existed for a long time, based on evidence from fossilized lightning strikes in ancient rocks, but observations of planetary lightning are necessarily much more recent. The generation and observations of lightning and other atmospheric electrical processes, both from within-atmosphere measurements, and spacecraft remote sensing, can be readily studied using a comparative planetology approach, with Earth as a model. All atmospheres contain charged molecules, electrons, and/or molecular clusters created by ionization from cosmic rays and other processes, which may affect an atmosphere's energy balance both through aerosol and cloud formation, and direct absorption of radiation. Several planets are anticipated to host a "global electric circuit" by analogy with the circuit occurring on Earth, where thunderstorms drive current of ions or electrons through weakly conductive parts of the atmosphere. This current flow may further modulate an atmosphere's radiative properties through cloud and aerosol effects. Lightning could potentially have implications for life through its effects on atmospheric chemistry and particle transport. It has been observed on many of the Solar System planets (Earth, Jupiter, Saturn, Uranus, and Neptune) and it may also be present on Venus and Mars. On Earth, Jupiter, and Saturn, lightning is thought to be generated in deep water and ice clouds, but discharges can be generated in dust, as for terrestrial volcanic lightning, and on Mars. Other, less well-understood mechanisms causing discharges in non-water clouds also seem likely. The discovery of thousands of exoplanets has recently led to a range of further exotic possibilities for atmospheric electricity, though lightning detection beyond our Solar System

  4. Painful menstrual periods

    Science.gov (United States)

    Menstruation - painful; Dysmenorrhea; Periods - painful; Cramps - menstrual; Menstrual cramps ... into two groups, depending on the cause: Primary dysmenorrhea Secondary dysmenorrhea Primary dysmenorrhea is menstrual pain that ...

  5. Middle Helladic Period

    DEFF Research Database (Denmark)

    Sarri, Kalliopi

    1999-01-01

    and their quality was improved considerably toward the end of this period. The profound cultural innovations of the Middle Helladic period were initially interpreted as a result of violent population movement and troubles provoked by the coming of the first Indo-European races. However, this matter does no more...... Helladic period is considered as a period of economic and social decline it was the time during which the mainland features merged with the insular influence, that is all the Aegean elements which led to the creation of the Mycenaean civilization were mixed in a creative way....

  6. Electric fields and electrical insulation

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson

    2002-01-01

    The adoption of a field-theoretical approach to problems arising in the framework of electrical insulation is discussed with reference to six main topics, which have been addressed over the last 30 years. These include uniform field electrodes, Green's differential equation, electrode surface...... roughness, induced charge, electrostatic probes, and partial discharge transients, together with several follow-on aspects. Each topic is introduced and thereafter the progress achieved through the use of a field-theoretical approach is reviewed. Because the topics cover a wide spectrum of conditions......, it is amply demonstrated that such an approach can lead to significant progress in many areas of electrical insulation....

  7. Chemical Detection using Electrically Open Circuits having no Electrical Connections

    Science.gov (United States)

    Woodward, Stanley E.; Olgesby, Donald M.; Taylor, Bryant D.; Shams, Qamar A.

    2008-01-01

    This paper presents investigations to date on chemical detection using a recently developed method for designing, powering and interrogating sensors as electrically open circuits having no electrical connections. In lieu of having each sensor from a closed circuit with multiple electrically connected components, an electrically conductive geometric pattern that is powered using oscillating magnetic fields and capable of storing an electric field and a magnetic field without the need of a closed circuit or electrical connections is used. When electrically active, the patterns respond with their own magnetic field whose frequency, amplitude and bandwidth can be correlated with the magnitude of the physical quantities being measured. Preliminary experimental results of using two different detection approaches will be presented. In one method, a thin film of a reactant is deposited on the surface of the open-circuit sensor. Exposure to a specific targeted reactant shifts the resonant frequency of the sensor. In the second method, a coating of conductive material is placed on a thin non-conductive plastic sheet that is placed over the surface of the sensor. There is no physical contact between the sensor and the electrically conductive material. When the conductive material is exposed to a targeted reactant, a chemical reaction occurs that renders the material non-conductive. The change in the material s electrical resistance within the magnetic field of the sensor alters the sensor s response bandwidth and amplitude, allowing detection of the reaction without having the reactants in physical contact with the sensor.

  8. On some periodicity effects

    DEFF Research Database (Denmark)

    Sorokin, Sergey V.

    2015-01-01

    The talk is concerned with the modelling of wave propagation in and vibration of periodic elastic structures. Although analysis of wave-guide properties of infinite periodic structures is a well establish research subject, some issues have not yet been fully addressed in the literature. The aim o...

  9. The Living Periodic Table

    Science.gov (United States)

    Nahlik, Mary Schrodt

    2005-01-01

    To help make the abstract world of chemistry more concrete eighth-grade students, the author has them create a living periodic table that can be displayed in the classroom or hallway. This display includes information about the elements arranged in the traditional periodic table format, but also includes visual real-world representations of the…

  10. Periods and Nori motives

    CERN Document Server

    Huber, Annette

    2017-01-01

    This book casts the theory of periods of algebraic varieties in the natural setting of Madhav Nori’s abelian category of mixed motives. It develops Nori’s approach to mixed motives from scratch, thereby filling an important gap in the literature, and then explains the connection of mixed motives to periods, including a detailed account of the theory of period numbers in the sense of Kontsevich-Zagier and their structural properties. Period numbers are central to number theory and algebraic geometry, and also play an important role in other fields such as mathematical physics. There are long-standing conjectures about their transcendence properties, best understood in the language of cohomology of algebraic varieties or, more generally, motives. Readers of this book will discover that Nori’s unconditional construction of an abelian category of motives (over fields embeddable into the complex numbers) is particularly well suited for this purpose. Notably, Kontsevich's formal period algebra represents a to...

  11. Project 2nd Periodic Report - Section 2

    DEFF Research Database (Denmark)

    Healy, Mark; Knowles, Emma; Johnstone, Cameron

    The work described in this publication has received support from the European Community - Research Infrastructure Action under the FP7 “Capacities” Specific Programme through grant agreement number 262552, MaRINET. Project Periodic Report. 2nd Period: October 2012 – March 2014 inclusive.......The work described in this publication has received support from the European Community - Research Infrastructure Action under the FP7 “Capacities” Specific Programme through grant agreement number 262552, MaRINET. Project Periodic Report. 2nd Period: October 2012 – March 2014 inclusive....

  12. Electricity Bill

    International Nuclear Information System (INIS)

    Blair, A.; Beith, A.J.; Hardy, P.

    1989-01-01

    The first part of the debate, which lasted a total of about 7 hours, a verbatim report of the first five of which are included here, was about energy conservation. Several new clauses and amendments were discussed. One would place a duty on the new Director of the Energy Supply industry to promote the efficiency and conservation of energy, another would appoint a Deputy Director with responsibility for energy conservation, and the third would require targets of energy efficiency and pollution reduction to be achieved. This allowed discussion on energy saving by domestic thermal insulation, improved efficiency of heating and refrigeration units and on renewable energy sources especially world energy. The second part of the debate was about access to information regarding health and safety resulting from any activities of the electricity supply industry. The remainder of the debate concerned regional representation and the economics of the electricity supply industry. (UK)

  13. Electricity unplugged

    Science.gov (United States)

    Karalis, Aristeidis

    2009-02-01

    The judge was driving back late one cold winter night. Entering the garage, the battery-charging indicator in his wirelessly powered electric car came on. "Home at last," crossed his mind. He swiped his personal smartcard on the front-door detector to be let in. He heard a "charging" beep from his mobile phone. The blinking cursor on the half-finished e-mail on the laptop had been waiting all day on the side table. He picked the computer up and walked towards his desk. "Good evening, your honour. Your wirelessly heated robe," said the butler-robot as it approached from the kitchen. Putting on the electric garment, he sat on the medical desk chair. His artificial heart was now beating faster.

  14. Electricity supply

    International Nuclear Information System (INIS)

    Rezendes, V.S.

    1991-10-01

    This report focuses on the Securities and Exchange Commission's (SEC) administration of the Public Utility Holding Company Act of 1935, intended to protect the public, investors, and consumers from abuses associated with the control of electric and gas utility companies through the holding company structure. These abuses include subjecting subsidiary utilities to excessive charges for services, construction work, and materials; frustrating effective state regulation through the holding company structure; and overloading subsidiary utilities with debt to prevent voluntary rate reductions. GAO discusses industry changes during the past decade involving electric utility holding companies; SEC's regulatory response to such changes; and the relationship between SEC, the Federal Energy Regulatory Commission, and states in protecting consumer and investor interests in light of these changes

  15. Electrical generator

    International Nuclear Information System (INIS)

    Purdy, D.L.

    1976-01-01

    A nuclear heart pacer having a heat-to-electricity converter including a solid-state thermoelectric unit embedded in rubber which is compressed to impress hydrostatic precompression on the unit is described. The converter and the radioactive heat source are enclosed in a container which includes the electrical circuit components for producing and controlling the pulses; the converter and components being embedded in rubber. The portions of the rubber in the converter and in the container through which heat flows between the radioactive primary source and the hot junction and between the cold junction and the wall of the container are of thermally conducting silicone rubber. The 238 Pu primary radioactive source material is encapsuled in a refractory casing of WC-222 (T-222) which in turn is encapsuled in a corrosion-resistant casing of platinum rhodium, a diffusion barrier separating the WC-222 and the Pt--Rh casings. The Pt--Rh casing is in a closed basket of tantalum. The tantalum protects the Pt--Rh from reacting with other materials during cremation of the host, if any. The casings and basket suppress the transmission of hard x rays generated by the alpha particles from the 238 Pu. The outside casing of the pacer is typically of titanium but its surface is covered by an electrically insulating coating, typically epoxy resin, except over a relatively limited area for effective electrical grounding to the body of the host. It is contemplated that the pacer will be inserted in the host with the exposed titanium engaging a non-muscular region of the body

  16. Electric Car

    Science.gov (United States)

    1977-01-01

    NASA's Lewis Research Center undertook research toward a practical, economical battery with higher energy density. Borrowing from space satellite battery technology, Lewis came up with a nickel-zinc battery that promises longer life and twice the range of the lead-acid counterpart. Lewis researchers fabricated a prototype battery and installed it in an Otis P-500 electric utility van, using only the battery space already available and allowing battery weight equal to that of the va's conventional lead-acid battery

  17. Electrical model of Olkiluoto

    Energy Technology Data Exchange (ETDEWEB)

    Paananen, M.; Lehtonen, T.; Korhonen, K. (Geological Survey of Finland, Espoo (FI))

    2007-05-15

    The goal of this work is to construct a composite electrical model of Olkiluoto, focussing on integration of four separate geophysical methods: mise-a-la-masse (MAM), SAMPO EM soundings, Slingram (HLEM) and single-hole electrical soundings. The electrical structure of Olkiluoto is rather complex, dominated by mineral electrical conductors such as sulphide minerals and graphite. The basic idea of this work is the fact that the sulphide-rich zones and fracturing appear to coincide frequently. Accordingly, knowing the geometry of the major electric conductors would facilitate the interpretation of brittle deformation zones. The work consists of three separate phases: method-specific interpretation, integration and block modelling. In the single-hole interpretation, locations of electric conductors (resistivity < 1000 ohmm), based on long normal survey have been determined in 42 drillholes. Since MAM survey does not cover all the conductive sections and drillholes and SAMPO EM has its own limitations in sensitivity and resolution, a proportion of the conductive sections have been combined between the drillholes using only the single-hole data and the geological idea of features dipping gently to SE - S. The MAM survey has been done in numerous drillholes in order to find galvanic connections between the drillholes. Based on MAM, geometry of numerous electric conductors has been determined. Generally the results indicate continuous, gently dipping semiplanar features intersected by several drillholes. The Slingram survey and interpretation have been done on the ground surface to map electric conductors located at shallow depths (some tens of meters at maximum). A number of conductive zones have been delineated, trending mainly from ENE to WSW. The conductors have also been classified according to their in-phase/quadrature-ratio, and in some cases, also numerical modelling has been done. The SAMPO EM soundings and interpretations have been done to map subsurface electric

  18. Electrical model of Olkiluoto

    International Nuclear Information System (INIS)

    Paananen, M.; Lehtonen, T.; Korhonen, K.

    2007-05-01

    The goal of this work is to construct a composite electrical model of Olkiluoto, focussing on integration of four separate geophysical methods: mise-a-la-masse (MAM), SAMPO EM soundings, Slingram (HLEM) and single-hole electrical soundings. The electrical structure of Olkiluoto is rather complex, dominated by mineral electrical conductors such as sulphide minerals and graphite. The basic idea of this work is the fact that the sulphide-rich zones and fracturing appear to coincide frequently. Accordingly, knowing the geometry of the major electric conductors would facilitate the interpretation of brittle deformation zones. The work consists of three separate phases: method-specific interpretation, integration and block modelling. In the single-hole interpretation, locations of electric conductors (resistivity < 1000 ohmm), based on long normal survey have been determined in 42 drillholes. Since MAM survey does not cover all the conductive sections and drillholes and SAMPO EM has its own limitations in sensitivity and resolution, a proportion of the conductive sections have been combined between the drillholes using only the single-hole data and the geological idea of features dipping gently to SE - S. The MAM survey has been done in numerous drillholes in order to find galvanic connections between the drillholes. Based on MAM, geometry of numerous electric conductors has been determined. Generally the results indicate continuous, gently dipping semiplanar features intersected by several drillholes. The Slingram survey and interpretation have been done on the ground surface to map electric conductors located at shallow depths (some tens of meters at maximum). A number of conductive zones have been delineated, trending mainly from ENE to WSW. The conductors have also been classified according to their in-phase/quadrature-ratio, and in some cases, also numerical modelling has been done. The SAMPO EM soundings and interpretations have been done to map subsurface electric

  19. Cutting force measurement of electrical jigsaw by strain gauges

    International Nuclear Information System (INIS)

    Kazup, L; Varadine Szarka, A

    2016-01-01

    This paper describes a measuring method based on strain gauges for accurate specification of electric jigsaw's cutting force. The goal of the measurement is to provide an overall perspective about generated forces in a jigsaw's gearbox during a cutting period. The lifetime of the tool is affected by these forces primarily. This analysis is part of the research and development project aiming to develop a special linear magnetic brake for realizing automatic lifetime tests of electric jigsaws or similar handheld tools. The accurate specification of cutting force facilitates to define realistic test cycles during the automatic lifetime test. The accuracy and precision resulted by the well described cutting force characteristic and the possibility of automation provide new dimension for lifetime testing of the handheld tools with alternating movement. (paper)

  20. Specification of a system for planning and analysis of independent generator connection impact on the electric distribution system; Especificacao de um sistema de planeamento e analise do impacto da conexao de geradores independentes no sistema electrico da distribuicao

    Energy Technology Data Exchange (ETDEWEB)

    Proenca, Luis Miguel; Matos, Manuel Antonio [Instituto de Engenharia de Sistemas e Computadores (INESC), Porto (Portugal); Campos, Manuel Luis Borges [Centro para a Excelencia na Distribuicao (CED), Sao Paulo, SP (Brazil)

    1999-07-01

    This paper describes a system for planning and analysis of the independent generator connection impact on the electric distribution system. This system is being developed under a contract signed between the Center for Excellency in the Distribution (CED), state of Sao Paulo - Brazil and the INESC, Porto - Portugal - energy unit.

  1. South Africa's electricity consumption: A sectoral decomposition analysis

    International Nuclear Information System (INIS)

    Inglesi-Lotz, Roula; Blignaut, James N.

    2011-01-01

    Highlights: → We conduct a decomposition exercise of the South African electricity consumption. → The increase in electricity consumption was due to output and structural changes. → The increasing at a low rate electricity intensity was a decreasing factor to consumption. → Increases in production were proven to be part of the rising trend for all sectors. → Only 5 sectors' consumption were negatively affected by efficiency improvements. -- Abstract: South Africa's electricity consumption has shown a sharp increase since the early 1990s. Here we conduct a sectoral decomposition analysis of the electricity consumption for the period 1993-2006 to determine the main drivers responsible for this increase. The results show that the increase was mainly due to output or production related factors, with structural changes playing a secondary role. While there is some evidence of efficiency improvements, indicated here as a slowdown in the rate of increase of electricity intensity, it was not nearly sufficient to offset the combined production and structural effects that propelled electricity consumption forward. This general economy-wide statement, however, can be misleading since the results, in essence, are very sector specific and the inter-sectoral differences are substantial. Increases in production were proven to be part of the rising trend for all sectors. However, only five out of fourteen sectors were affected by efficiency improvements, while the structural changes affected the sectors' electricity consumption in different ways. These differences concerning the production, structural and efficiency effects on the sectors indicate the need for a sectoral approach in the energy policy-making of the country rather than a blanket or unilateral economy-wide approach.

  2. Mean-periodic functions

    Directory of Open Access Journals (Sweden)

    Carlos A. Berenstein

    1980-01-01

    Full Text Available We show that any mean-periodic function f can be represented in terms of exponential-polynomial solutions of the same convolution equation f satisfies, i.e., u∗f=0(μ∈E′(ℝn. This extends to n-variables the work of L. Schwartz on mean-periodicity and also extends L. Ehrenpreis' work on partial differential equations with constant coefficients to arbitrary convolutors. We also answer a number of open questions about mean-periodic functions of one variable. The basic ingredient is our work on interpolation by entire functions in one and several complex variables.

  3. Financing electricity expansion

    International Nuclear Information System (INIS)

    Hyman, L.S.

    1994-01-01

    Expansion of electricity supply is associated with economic development. The installation and enlargement of power systems in developing countries entails a huge financial burden, however. Energy consumers in such countries must pay not only for supplies but for the cost of raising the capital for expansion on the international markets. Estimates are presented for the capital expenditure for electricity supply over the period 1990 to 2020 for the major world regions, using approximations for the cost of plant and capital and for the returns earned. These data lead to the conclusion that the five regions with the lowest per capita incomes are those which will need the major part of the capital expenditure and the highest percentage of external finance. (6 tables) (UK)

  4. The relationship between electricity consumption, electricity prices and GDP in Pakistan

    International Nuclear Information System (INIS)

    Jamil, Faisal; Ahmad, Eatzaz

    2010-01-01

    This study analyzes the relationship among electricity consumption, its price and real GDP at the aggregate and sectoral level in Pakistan. Using annual data for the period 1960-2008, the study finds the presence of unidirectional causality from real economic activity to electricity consumption. In particular, growth in output in commercial, manufacturing and agricultural sectors tend to increase electricity consumption, while in residential sector, growth in private expenditures is the cause of rising electricity consumption. The study concludes that electricity production and management needs to be better integrated with overall economic planning exercises. This is essential to avoid electricity shortfalls and unplanned load shedding.

  5. Evaluation of Electrical Characteristics of Protective Equipment - a Prerequisite for Ensuring Safety and Health of Workers at Work

    Science.gov (United States)

    Buică, G.; Beiu, C.; Antonov, A.; Dobra, R.; Păsculescu, D.

    2017-06-01

    The protecting electrical equipment in use are subject to various factors generated by the use, maintenance, storage and working environment, which may change the characteristics of protection against electric shock. The study presents the results of research on the behaviour over time of protective characteristics of insulating covers of material of work equipment in use, in order to determine the type and periodicity of safety tests. There were tested and evaluated safety equipment with plastic and insulating rubber covers used in operations of verifying functionality, safety and maintenance of machinery used in manufacturing industries and specific services from electric, energy and food sector.

  6. evaluation of electricity consumer's behaviour towards electricity ...

    African Journals Online (AJOL)

    Energy efficiency and sustainability: evaluation of electricity consumer's behaviour towards electricity usage and energy conservation. ... Remember me ... particularly about electricity consumer's attitudes, behaviour and practices with respect ...

  7. Painful periods (dysmenorrhea) (image)

    Science.gov (United States)

    Primary dysmenorrhea is a normal cramping of the lower abdomen caused by hormone-induced uterine contractions before the period. Secondary dysmenorrhea may be caused by abnormal conditions such as ...

  8. Vaginal bleeding between periods

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003156.htm Vaginal bleeding between periods To use the sharing features ... this page, please enable JavaScript. This article discusses vaginal bleeding that occurs between a woman's monthly menstrual ...

  9. Super periodic potential

    Science.gov (United States)

    Hasan, Mohammd; Mandal, Bhabani Prasad

    2018-04-01

    In this paper we introduce the concept of super periodic potential (SPP) of arbitrary order n, n ∈I+, in one dimension. General theory of wave propagation through SPP of order n is presented and the reflection and transmission coefficients are derived in their closed analytical form by transfer matrix formulation. We present scattering features of super periodic rectangular potential and super periodic delta potential as special cases of SPP. It is found that the symmetric self-similarity is the special case of super periodicity. Thus by identifying a symmetric fractal potential as special cases of SPP, one can obtain the tunnelling amplitude for a particle from such fractal potential. By using the formalism of SPP we obtain the close form expression of tunnelling amplitude of a particle for general Cantor and Smith-Volterra-Cantor potentials.

  10. Establishing contract periods

    International Nuclear Information System (INIS)

    Huffman, F.C.

    1978-01-01

    The lead time for executing the Adjustable Fixed-Commitment (AFC) contract and exceptions which may be considered are discussed. The initial delivery period is also discussed. Delays, deferrals, and schedule adjustment charges are finally considered

  11. The Periodic Table CD.

    Science.gov (United States)

    Banks, Alton J.; Holmes, Jon L.

    1995-01-01

    Describes the characteristics of the digitized version of The Periodic Table Videodisc. Provides details about the organization of information and access to the data via Macintosh and Windows computers. (DDR)

  12. Setting the Periodic Table.

    Science.gov (United States)

    Saturnelli, Annette

    1985-01-01

    Examines problems resulting from different forms of the periodic table, indicating that New York State schools use a form reflecting the International Union of Pure and Applied Chemistry's 1984 recommendations. Other formats used and reasons for standardization are discussed. (DH)

  13. Supersymmetrically transformed periodic potentials

    OpenAIRE

    C, David J. Fernandez

    2003-01-01

    The higher order supersymmetric partners of a stationary periodic potential are studied. The transformation functions associated to the band edges do not change the spectral structure. However, when the transformation is implemented for factorization energies inside of the forbidden bands, the final potential will have again the initial band structure but it can have bound states encrusted into the gaps, giving place to localized periodicity defects.

  14. Thyrotoxic periodic paralysis

    OpenAIRE

    Rojith Karandode Balakrishnan; Suresh Rama Chandran; Geetha Thirumalnesan; Nedumaran Doraisamy

    2011-01-01

    This article aims at highlighting the importance of suspecting thyrotoxicosis in cases of recurrent periodic flaccid paralysis; especially in Asian men to facilitate early diagnosis of the former condition. A case report of a 28 year old male patient with recurrent periodic flaccid paralysis has been presented. Hypokalemia secondary to thyrotoxicosis was diagnosed as the cause of the paralysis. The patient was given oral potassium intervention over 24 hours. The patient showed complete recove...

  15. Electricity demand forecasting using regression, scenarios and pattern analysis

    CSIR Research Space (South Africa)

    Khuluse, S

    2009-02-01

    Full Text Available The objective of the study is to forecast national electricity demand patterns for a period of twenty years: total annual consumption and understanding seasonal effects. No constraint on the supply of electricity was assumed...

  16. Report of the electric Equipment Service - Annex E

    International Nuclear Information System (INIS)

    Sanovic, V.

    1990-01-01

    This report describes organisational structure of the Service dealing with control and maintenance of electrical supply system and equipment. It includes detailed data about electric power consumption, power cuts and failures during the past period [sr

  17. Report of the electric Equipment Service - Annex E

    International Nuclear Information System (INIS)

    Sanovic, V.

    1987-01-01

    This report describes organisational structure of the Service dealing with control and maintenance of electrical supply system and equipment. It includes detailed data about electric power consumption, power cuts and failures during the past period [sr

  18. Report of the electric Equipment Service - Annex E

    International Nuclear Information System (INIS)

    Sanovic, V.

    1988-01-01

    This report describes organisational structure of the Service dealing with control and maintenance of electrical supply system and equipment. It includes detailed data about electric power consumption, power cuts and failures during the past period [sr

  19. Report of the electric Equipment Service - Annex E

    International Nuclear Information System (INIS)

    Tanaskovic, M.

    1995-01-01

    This report describes organisational structure of the Service dealing with control and maintenance of electrical supply system and equipment. It includes detailed data about electric power consumption, power cuts and failures during the past period [sr

  20. Electric utilities in 2007

    Energy Technology Data Exchange (ETDEWEB)

    Hyman, L.S. [Smith Barney Inc., New York, NY (United States)

    1998-10-01

    A century ago--in the year J.J. Thomson discovered the electron--electricity, gas and traction companies battled for markets, and corrupt city councils demanded their fair share of the take. One tycoon became so disgusted with the confusion and dishonesty that he decided to bribe the legislature to set up an honest, state-run regulatory agency that would bring order to chaos. But he was found out. The scandal set back the cause of regulation until 1907, the year in which the electric washing machine and the vacuum cleaner were invented. By then, electricity sales had septupled from 1897 levels, and three states had established utility regulation. In the coming decade, 1997 to 2007, the utility business could undergo similar dramatic change, but it will move toward less regulation and more competition during a period of slow growth. Management will have to work harder to achieve success, however, because much of the profits will have to come not from a growing market but from the pockets of competitors. By 2007, electricity will constitute a component of a larger energy and utility services industry that sells electricity, natural gas and possibly water, propane and telecommunications. Customized service will meet the needs of consumers of all sizes. The dominant firm in the industry, the virtual utility, may look more like a financial organization or a mass marketer than the traditional converter of raw material to energy. Emphasis on market-based pricing should lead to more efficient use of resources. If the process works right, the consumer wins.

  1. Electrical requirements for unshielded glove boxes

    International Nuclear Information System (INIS)

    1978-02-01

    The specification relates to the general design and installation of electrical services required in unshielded glove boxes in which atmospheres of air, argon or nitrogen etc. may exist either temporarily or permanently. The specification does not apply to electrical services for glove boxes with flammable explosive atmospheres. (author)

  2. Natural-gas-powered thermoelectricity as a reliability factor in the Brazilian electric sector

    International Nuclear Information System (INIS)

    Fernandes, E.; Oliveira, J.C.S. de; de Oliveira, P.R.; Alonso, P.S.R.

    2008-01-01

    The introduction of natural-gas-powered thermoelectricity into the Brazilian generation sector can be considered as a very complex energy, economic, regulatory and institutional revision. Brazil is a country with very specific characteristics in electricity generation, as approximately 80% of the generating capacity is based on hydroelectricity, showing strong dependency on rain and management of water reservoirs. A low rate of investment in the Brazilian Electricity Industry in the period of 1995-2000, associated with periods of low rainfall, led to a dramatic lowering of the water stocks in the reservoirs. With this scenario and the growing supply of natural gas, both from within Brazil and imported, natural gas thermal electric plants became a good option to diversify the electrical supply system. In spite of the Brazilian Government's efforts to install such plants, the country was faced with severe electricity rationing in 2001. The objective of this work is to show the need to continue with the implementation of natural gas thermal electricity projects, in a manner that allows flexibility and guarantees greater working reliability for the entire Brazilian electricity sector. Taking into account the world trend towards renewable energy, the perspectives of usage of biofuels in the Brazilian Energy Matrix and in electrical energy generation are also analyzed. The very issue of electrical power efficiency in Brazil and its challenges and strategic proposals from the standpoint of Government Programs and results provided so far are presented. The technological constraints in order to put on stream the thermal electric plants are also analyzed. The article concludes with a positive perspective of the usage of natural gas as to be the third pillar in the Brazilian Energy Matrix for the years to come

  3. Periodical inspection in nuclear power stations

    International Nuclear Information System (INIS)

    1986-01-01

    Periodical inspection is presently being made of eight nuclear power plants in nuclear power stations. Up to the present time, in three of them, failures as follows have been observed. (1) Unit 3 (PWR) of the Mihama Power Station in The Kansai Electric Power Co., Inc. Nineteen heat-transfer tubes of the steam generators were plugged up due to failure. A fuel assembly with a failed spring fixture and in another the control-rod cluster with a failed control rod fixture were replaced. (2) Unit 2 (PWR) of the Oi Power Station in The Kansai Electric Power Co., Inc. Eight heat-transfer tubes of the heat exchangers were plugged up due to failure. (3) Unit 6 (BWR) of the Fukushima Nuclear Power Station I in The Tokyo Electric Power Co., Inc. A fuel assembly with leakage was replaced. (Mori, K.)

  4. Synaptic Effects of Electric Fields

    Science.gov (United States)

    Rahman, Asif

    Learning and sensory processing in the brain relies on the effective transmission of information across synapses. The strength and efficacy of synaptic transmission is modifiable through training and can be modulated with noninvasive electrical brain stimulation. Transcranial electrical stimulation (TES), specifically, induces weak intensity and spatially diffuse electric fields in the brain. Despite being weak, electric fields modulate spiking probability and the efficacy of synaptic transmission. These effects critically depend on the direction of the electric field relative to the orientation of the neuron and on the level of endogenous synaptic activity. TES has been used to modulate a wide range of neuropsychiatric indications, for various rehabilitation applications, and cognitive performance in diverse tasks. How can a weak and diffuse electric field, which simultaneously polarizes neurons across the brain, have precise changes in brain function? Designing therapies to maximize desired outcomes and minimize undesired effects presents a challenging problem. A series of experiments and computational models are used to define the anatomical and functional factors leading to specificity of TES. Anatomical specificity derives from guiding current to targeted brain structures and taking advantage of the direction-sensitivity of neurons with respect to the electric field. Functional specificity originates from preferential modulation of neuronal networks that are already active. Diffuse electric fields may recruit connected brain networks involved in a training task and promote plasticity along active synaptic pathways. In vitro, electric fields boost endogenous synaptic plasticity and raise the ceiling for synaptic learning with repeated stimulation sessions. Synapses undergoing strong plasticity are preferentially modulated over weak synapses. Therefore, active circuits that are involved in a task could be more susceptible to stimulation than inactive circuits

  5. Electrical aspects of rainout

    International Nuclear Information System (INIS)

    Rosenkilde, C.E.

    1981-01-01

    Rainout commonly denotes the aggregate of phenomena associated with precipitation scavenging of radioactivity from a cloud of nuclear debris that is within a natural rain cloud. (In contrast, the term, washout, is applicable when the nuclear cloud is below the rain cloud and the term, fallout, commonly denotes the direct gravitational settling of contaminated solid material from a nuclear cloud.) Nuclear debris aerosols may be scavenged within natural clouds by a variety of different physical processes which may involve diffusion, convection, impaction, nucleation, phoresis, turbulence, and/or electricity among others. Processes which involve electrical aspects are scrutinized for their susceptibility to the intimate presence of the radioactive-cloud environment. This particular choice of electrical processes is not accidental. Nearly all of the listed processes were examined earlier by Williams. His rough estimates suggested that electrical effects, and to a lesser extent turbulence, could enhance the scavenging of those submicron aerosols which reside in the size-range that bridges the minimum in the scavenging rate coefficient which is commonly called the Greenfield gap. This minimum in the scavenging-rate coefficient is created by the simultaneous reduction of scavenging via diffusion and the reduction of scavenging via inertial impaction. However, Williams omitted the specific influence of a radioactive environment. This report aims to remedy this omission

  6. Electrical transmission

    Energy Technology Data Exchange (ETDEWEB)

    Sayers, D P

    1960-05-01

    After briefly tracing the history of electricity transmission, trends in high voltage transmission and experiments being conducted on 650 kV are discussed. 5000 miles of the U.K. grid are operated at 132 kV and 1000 at 275 kV, ultimately to provide a super grid at 380 kV. Problems are insulation, radio interference and the cost of underground lines (16 times that of overhead lines). Also considered are the economics of the grid as a means of transporting energy and as a means of spreading the peak load over the power stations in the most efficient manner. Finally, the question of amenities is discussed.

  7. Electric rivers

    International Nuclear Information System (INIS)

    McCutcheon, S.

    1992-04-01

    James Bay II, the projected Canadian hydroelectric power plant of gigantic dimensions, is to deliver its electricity to Europe: in the USA, opposition to power imports from James Bay is growing. Its realization means the flooding of an area as big as the Federal Republic of Germany; the native territory and hunting grounds of the Cree indians would be inundated. The interests of the European power industry in the James Bay project and the consequences for Europe are described in an appendix (EQHHPP project, project management Hydro-Quebec and Ludwig Boelkow Foundation, hydrogen production through electrolysis, methods for transporting hydrogen to Hamburg). (orig./HP) [de

  8. Dielectric materials for electrical engineering

    CERN Document Server

    Martinez-Vega, Juan

    2013-01-01

    Part 1 is particularly concerned with physical properties, electrical ageing and modeling with topics such as the physics of charged dielectric materials, conduction mechanisms, dielectric relaxation, space charge, electric ageing and life end models and dielectric experimental characterization. Part 2 concerns some applications specific to dielectric materials: insulating oils for transformers, electrorheological fluids, electrolytic capacitors, ionic membranes, photovoltaic conversion, dielectric thermal control coatings for geostationary satellites, plastics recycling and piezoelectric poly

  9. Consumer knowledge and electricity consumption

    Energy Technology Data Exchange (ETDEWEB)

    Crawshaw, A J.E.; Williams, D I; Crawshaw, C M

    1985-12-01

    Householders in all-electric homes were asked to rank their electrical appliances in terms of annual running cost. By comparing this with an individually calculated correct order, an assessment of their knowledge was made. On this measure overall knowledge was good, but half the sample underestimated the running costs of key high-energy using appliances (space heating, hot-water, cooking). This specific lack of knowledge is critical, and was found to be correlated with higher bills. 16 references.

  10. Electrical Resistivity Measurements: a Review

    Science.gov (United States)

    Singh, Yadunath

    World-wide interest on the use of ceramic materials for aerospace and other advanced engineering applications, has led to the need for inspection techniques capable of detecting unusually electrical and thermal anomalies in these compounds. Modern ceramic materials offer many attractive physical, electrical and mechanical properties for a wide and rapidly growing range of industrial applications; moreover specific use may be made of their electrical resistance, chemical resistance, and thermal barrier properties. In this review, we report the development and various techniques for the resistivity measurement of solid kind of samples.

  11. Ex Vivo Assay of Electrical Stimulation to Rat Sciatic Nerves: Cell Behaviors and Growth Factor Expression.

    Science.gov (United States)

    Du, Zhiyong; Bondarenko, Olexandr; Wang, Dingkun; Rouabhia, Mahmoud; Zhang, Ze

    2016-06-01

    Neurite outgrowth and axon regeneration are known to benefit from electrical stimulation. However, how neuritis and their surroundings react to electrical field is difficult to replicate by monolayer cell culture. In this work freshly harvested rat sciatic nerves were cultured and exposed to two types of electrical field, after which time the nerve tissues were immunohistologically stained and the expression of neurotrophic factors and cytokines were evaluated. ELISA assay was used to confirm the production of specific proteins. All cell populations survived the 48 h culture with little necrosis. Electrical stimulation was found to accelerate Wallerian degeneration and help Schwann cells to switch into migratory phenotype. Inductive electrical stimulation was shown to upregulate the secretion of multiple neurotrophic factors. Cellular distribution in nerve tissue was altered upon the application of an electrical field. This work thus presents an ex vivo model to study denervated axon in well controlled electrical field, bridging monolayer cell culture and animal experiment. It also demonstrated the critical role of electrical field distribution in regulating cellular activities. © 2015 Wiley Periodicals, Inc.

  12. Strategy for development of the Polish electricity sector

    Energy Technology Data Exchange (ETDEWEB)

    Dybowski, J. [Polish Power Grid Co., Warsaw (Poland)

    1995-12-01

    This paper represents the strategy for development of the Polish Electricity Sector dealing with specific problems which are common for all of East Central Europe. In 1990 Poland adopted a restructuring program for the entire energy sector. Very ambitious plans were changed several times but still the main direction of change was preserved. The most difficult period of transformation is featured by several contradictions which have to be balanced. Electricity prices should increase in order to cover the modernization and development program but the society is not able to take this burden in such a short time. Furthermore the new environment protection standards force the growth of capital investment program which sooner or later has to be transferred through the electricity prices. New economic mechanisms have to be introduced to the electricity sector to replace the old ones noneffective, centrally planned. This process has to follow slow management changes. Also, introduction of new electricity market is limited by those constraints. However, this process of change would not be possible without parallel governmental initiation like preparation of new energy law and regulatory frames.

  13. Electric crossover

    International Nuclear Information System (INIS)

    Schuster, R.M.; Luria, N.G.

    1977-01-01

    This invention concerns an electric crossover that makes a steam and pressure-tight seal for a conductor crossing two separate walls of a nuclear reactor vessel that seismic tremors or thermal expansion of the walls and conductor subject to relative displacements. The conductors, that have to cross the vessels, are fixed to the walls of the vessel in crossover systems fitted in crossover channels made in the walls of the vessel on their initial manufacture. The separate walls of the vessel move independently when they undergo an earth tremor or a temperature change between the walls or between the conductor. This shift can damage the conductor or the crossover system and this could give rise to cause steam or other materials to leak in the reactor should leaks occur in the primary system. Furthermore, in the case of medium or high power conductors, which are relatively rigid, the non-alignment of the crossover channels can bring about awkward stresses in the conductors or their protective sheathing. The aims of this invention are fulfilled by designing an electric crossover to pass at least one conductor through the two separate walls of a vessels, that includes an initial sub-assembly crossover, secured in a leak-tight manner to the first wall and a second sub-sessembly crossover in sliding or rolling contact with the second wall, whilst forming a leak-tight seal with it [fr

  14. Resonances in a periodically driven bosonic system

    NARCIS (Netherlands)

    Quelle, Anton; de Morais Smith, Cristiane

    2017-01-01

    Periodically driven systems are a common topic in modern physics. In optical lattices specifically, driving is at the origin of many interesting phenomena. However, energy is not conserved in driven systems, and under periodic driving, heating of a system is a real concern. In an effort to better

  15. Periodic table of elements

    International Nuclear Information System (INIS)

    Fluck, E.; Heumann, K.G.

    1985-01-01

    Following a recommendation by the International Union for Pure and Applied Chemistry (IUPAC), the groups of the periodic table shall be numbered from 1 to 18, instead of I to VIII as before. The recommendations has been approved of by the Committee on Nomenclature of the American Chemical Society. The new system abandons the distinction between main groups (a) and auxiliary groups (b), which in the past frequently has been the reason for misunderstandings between European and American chemists, due to different handling. The publishing house VCH Verlagsgesellschaft recently produced a new periodic table that shows the old and the new numbering system together at a glance, so that chemists will have time to get familiar with the new system. In addition the new periodic table represents an extensive data compilation arranged by elements. The front page lists the chemical properties of elements, the back page their physical properties. (orig./EF) [de

  16. Thyrotoxic periodic paralysis

    Directory of Open Access Journals (Sweden)

    Rojith Karandode Balakrishnan

    2011-01-01

    Full Text Available This article aims at highlighting the importance of suspecting thyrotoxicosis in cases of recurrent periodic flaccid paralysis; especially in Asian men to facilitate early diagnosis of the former condition. A case report of a 28 year old male patient with recurrent periodic flaccid paralysis has been presented. Hypokalemia secondary to thyrotoxicosis was diagnosed as the cause of the paralysis. The patient was given oral potassium intervention over 24 hours. The patient showed complete recovery after the medical intervention and was discharged after 24 hours with no residual paralysis. Thyrotoxic periodic paralysis (TPP is a complication of thyrotoxicosis, more common amongst males in Asia. It presents as acute flaccid paralysis in a case of hyperthyroidism with associated hypokalemia. The features of thyrotoxicosis may be subtle or absent. Thus, in cases of recurrent or acute flaccid muscle paralysis, it is important to consider thyrotoxicosis as one of the possible causes, and take measures accordingly.

  17. Content analysis of 150 years of British periodicals.

    Science.gov (United States)

    Lansdall-Welfare, Thomas; Sudhahar, Saatviga; Thompson, James; Lewis, Justin; Cristianini, Nello

    2017-01-24

    Previous studies have shown that it is possible to detect macroscopic patterns of cultural change over periods of centuries by analyzing large textual time series, specifically digitized books. This method promises to empower scholars with a quantitative and data-driven tool to study culture and society, but its power has been limited by the use of data from books and simple analytics based essentially on word counts. This study addresses these problems by assembling a vast corpus of regional newspapers from the United Kingdom, incorporating very fine-grained geographical and temporal information that is not available for books. The corpus spans 150 years and is formed by millions of articles, representing 14% of all British regional outlets of the period. Simple content analysis of this corpus allowed us to detect specific events, like wars, epidemics, coronations, or conclaves, with high accuracy, whereas the use of more refined techniques from artificial intelligence enabled us to move beyond counting words by detecting references to named entities. These techniques allowed us to observe both a systematic underrepresentation and a steady increase of women in the news during the 20th century and the change of geographic focus for various concepts. We also estimate the dates when electricity overtook steam and trains overtook horses as a means of transportation, both around the year 1900, along with observing other cultural transitions. We believe that these data-driven approaches can complement the traditional method of close reading in detecting trends of continuity and change in historical corpora.

  18. New conducted electrical weapons: Electrical safety relative to relevant standards.

    Science.gov (United States)

    Panescu, Dorin; Nerheim, Max; Kroll, Mark W; Brave, Michael A

    2017-07-01

    We have previously published about TASER ® conducted electrical weapons (CEW) compliance with international standards. CEWs deliver electrical pulses that can inhibit a person's neuromuscular control or temporarily incapacitate. An eXperimental Rotating-Field (XRF) waveform CEW and the X2 CEW are new 2-shot electrical weapon models designed to target a precise amount of delivered charge per pulse. They both can deploy 1 or 2 dart pairs, delivered by 2 separate cartridges. Additionally, the XRF controls delivery of incapacitating pulses over 4 field vectors, in a rotating sequence. As in our previous study, we were motivated by the need to understand the cardiac safety profile of these new CEWs. The goal of this paper is to analyze the nominal electrical outputs of TASER XRF and X2 CEWs in reference to provisions of all relevant international standards that specify safety requirements for electrical medical devices and electrical fences. Although these standards do not specifically mention CEWs, they are the closest electrical safety standards and hence give very relevant guidance. The outputs of several TASER XRF and X2 CEWs were measured under normal operating conditions. The measurements were compared against manufacturer specifications. CEWs electrical output parameters were reviewed against relevant safety requirements of UL 69, IEC 60335-2-76 Ed 2.1, IEC 60479-1, IEC 60479-2, AS/NZS 60479.1, AS/NZS 60479.2, IEC 60601-1 and BS EN 60601-1. Our study confirmed that the nominal electrical outputs of TASER XRF and X2 CEWs lie within safety bounds specified by relevant standards.

  19. Electric-Drive Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Septon, Kendall K [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-11

    Electric-drive vehicles use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. These vehicles can be divided into three categories: Hybrid electric vehicles (HEVs), Plug-in hybrid electric vehicles (PHEVs), All-electric vehicles (EVs). Together, PHEVs and EVs can also be referred to as plug-in electric vehicles (PEVs).

  20. Electric-Drive Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-09-01

    Electric-drive vehicles use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. These vehicles can be divided into three categories: Hybrid electric vehicles (HEVs), Plug-in hybrid electric vehicles (PHEVs), All-electric vehicles (EVs). Together, PHEVs and EVs can also be referred to as plug-in electric vehicles (PEVs).

  1. Design of grid connected PV systems considering electrical, economical and environmental aspects: A practical case

    International Nuclear Information System (INIS)

    Fernandez-Infantes, Alberto; Contreras, Javier; Bernal-Agustin, Jose L.

    2006-01-01

    This paper presents the complete design of a photovoltaic installation that may be either used for internal electric consumption or for sale using the premium subsidy awarded by the Spanish Government. Electric optimization strategies are detailed in the project, as well as the sizing of the photovoltaic installation and economic and financial issues related to it. The project optimizes the electricity demand, improving reactive power and studying the convenience of hourly discrimination fees in addition to the design of the photovoltaic installation. A specific computer application for the automated calculation of all relevant parameters of the installation-physical, electrical, economical as well as ecological-has been developed to make the process of calculating photovoltaic installations easier and to reduce the design development time. Moreover, the budget of the photovoltaic installation is included, as well as its corresponding financial ratios and payback periods. Finally, the conclusions reached in the technical and economic design of the installation are shown. (author)

  2. On the stability of preferences and attitudes before and after experiencing an electric vehicle

    DEFF Research Database (Denmark)

    Jensen, Anders Fjendbo; Cherchi, Elisabetta; Mabit, Stefan Lindhard

    2013-01-01

    -wave stated preference experiment where data was collected before and after the respondents experienced an electric vehicle for three months. We estimate a hybrid choice model using jointly the stated choices before and after the test period. The results show that individual preferences change significantly......In this study, we investigate the extent to which experience affects individual preferences for specific electric vehicle characteristics, individual attitudes toward the environment, and the impact of the attitudes on the choice between an electric and a conventional vehicle. We use a two...... after a real experience with an electric vehicle in the household. In particular, there are major changes in the preference for driving range, top speed, fuel cost, battery life and charging in city centres and train stations. In line with other studies, we find that environmental concern has a positive...

  3. Export of electric power through industrial products

    International Nuclear Information System (INIS)

    Azevedo, J.B.L. de; David, J.M.S.; Campos, J.M.; Perecmanis, J.; Carneiro, N.S.

    1990-01-01

    We forecast the electrical energy incorporated to the exports of products of the industrial sectors of steel, aluminium, ferro-alloys, chlorine and caustic soda, pulp and paper and petrochemistry, accordingly to scenarios for these sectors consistent with a macro economic reference scenario, for the period 1990/2000. We also compare the electrical energy exported through those industrial products with the forecasted industrial and total markets of electrical energy. (author)

  4. Shaping the future of electric utilities

    International Nuclear Information System (INIS)

    Byus, L.C.

    1993-01-01

    On December 14, 1992, Cincinnati Gas ampersand Electric Company (CG ampersand E) and PSI Resources, Inc. announced an agreement to merge the two companies into a newly formed company, CINergy Corp. In announcing the proposed merger, James E. Rogers Jr., chairman, president, and chief executive officer of PSI said, Our companies have chosen to shape our future and our industry. This is an ideal partnership, since our strengths complement each other and our vision of the future is the same. Will this merger be the first of many that will shape the future of the electric utility in the United States? What is the vision of the future for the industry? About five years ago, a well-known Wall Street utility analyst traveled around the country talking about the anticipated consolidation of electric utility companies in the US His motto was Fifty in Five, meaning widespread consolidation that would reduce the number of independent investor-owned utilities from more than 100 to 50 within a five-year period. He even developed a map showing the mergers/consolidations he looked for and actually named names. More than five years have passed, and only a handful of utility mergers have taken place. But, looking forward from 1992, restructuring of the utility industry is very much a vision of the future. What is the driving force? The National Energy Policy Act of 1992 provides the legislative framework for the electric utility industry in the US in future years. While the specific rules that will govern the industry are yet to be promulgated, the intent to allow (even promote) competition is evident in the Act itself. But it appears the vision of the future is market driven

  5. Periodically poled silicon

    Science.gov (United States)

    Hon, Nick K.; Tsia, Kevin K.; Solli, Daniel R.; Khurgin, Jacob B.; Jalali, Bahram

    2010-02-01

    Bulk centrosymmetric silicon lacks second-order optical nonlinearity χ(2) - a foundational component of nonlinear optics. Here, we propose a new class of photonic device which enables χ(2) as well as quasi-phase matching based on periodic stress fields in silicon - periodically-poled silicon (PePSi). This concept adds the periodic poling capability to silicon photonics, and allows the excellent crystal quality and advanced manufacturing capabilities of silicon to be harnessed for devices based on χ(2)) effects. The concept can also be simply achieved by having periodic arrangement of stressed thin films along a silicon waveguide. As an example of the utility, we present simulations showing that mid-wave infrared radiation can be efficiently generated through difference frequency generation from near-infrared with a conversion efficiency of 50% based on χ(2) values measurements for strained silicon reported in the literature [Jacobson et al. Nature 441, 199 (2006)]. The use of PePSi for frequency conversion can also be extended to terahertz generation. With integrated piezoelectric material, dynamically control of χ(2)nonlinearity in PePSi waveguide may also be achieved. The successful realization of PePSi based devices depends on the strength of the stress induced χ(2) in silicon. Presently, there exists a significant discrepancy in the literature between the theoretical and experimentally measured values. We present a simple theoretical model that produces result consistent with prior theoretical works and use this model to identify possible reasons for this discrepancy.

  6. Hereditary periodic fever syndromes

    NARCIS (Netherlands)

    McDermott, MF; Frenkel, J

    Hereditary periodic fever syndromes are defined by recurrent attacks of generalised inflammation for which no infectious or auto-immune cause can be identified. For most of these disorders, the molecular basis has recently been elucidated. This has opened the prospect of novel therapeutic

  7. Almost periodic Schroedinger operators

    International Nuclear Information System (INIS)

    Bellissard, J.; Lima, R.

    1984-01-01

    These lectures are devoted to recent developments in the theory of almost-periodic Schroedinger Operators. We specially describe the algebraic point of view, with applications to gap-labelling theorems. Particular models are also presented which exhibit various spectral properties. (orig.)

  8. Astrophysical implications of periodicity

    International Nuclear Information System (INIS)

    Muller, R.A.

    1988-01-01

    Two remarkable discoveries of the last decade have profound implications for astrophysics and for geophysics. These are the discovery by Alvarez et al., that certain mass extinctions are caused by the impact on the earth of a large asteroid or comet, and the discovery by Raup and Sepkoski that such extinctions are periodic, with a cycle time of 26 to 30 million years. The validity of both of these discoveries is assumed and the implications are examined. Most of the phenomena described depend not on periodicity, but just on the weaker assumption that the impacts on the earth take place primarily in showers. Proposed explanations for the periodicity include galactic oscillations, the Planet X model, and the possibility of Nemesis, a solar companion star. These hypotheses are critically examined. Results of the search for the solar companion are reported. The Deccan flood basalts of India have been proposed as the impact site for the Cretaceous impact, but this hypotheisis is in contradiction with the conclusion of Courtillot et al., that the magma flow began during a period of normal magnetic field. A possible resolution of this contradiction is proposed

  9. Periodic Table of Students.

    Science.gov (United States)

    Johnson, Mike

    1998-01-01

    Presents an exercise in which an eighth-grade science teacher decorated the classroom with a periodic table of students. Student photographs were arranged according to similarities into vertical columns. Students were each assigned an atomic number according to their placement in the table. The table is then used to teach students about…

  10. A Modern Periodic Table.

    Science.gov (United States)

    Herrenden-Harker, B. D.

    1997-01-01

    Presents a modern Periodic Table based on the electron distribution in the outermost shell and the order of filling of the sublevels within the shells. Enables a student to read off directly the electronic configuration of the element and the order in which filling occurs. (JRH)

  11. ELECTRICAL PROPERTIES OF COW AND SHEEP'S BONES

    OpenAIRE

    Sawsan Ahmed Elhouri Ahmed; Mubarak Dirar Abdallah2

    2017-01-01

    In this work five samples of (cow and sheep's bones) were prepared to powders in a period of crashing (10 up to 50 sec); weight = 56.73mg To find values of: Refractive index Energy gap And Electrical Conductivity

  12. A periodic table for cancer.

    Science.gov (United States)

    Epstein, Richard J

    2015-01-01

    Cancers exhibit differences in metastatic behavior and drug sensitivity that correlate with certain tumor-specific variables such as differentiation grade, growth rate/extent and molecular regulatory aberrations. In practice, patient management is based on the past results of clinical trials adjusted for these biomarkers. Here, it is proposed that treatment strategies could be fine-tuned upfront simply by quantifying tumorigenic spatial (cell growth) and temporal (genetic stability) control losses, as predicted by genetic defects of cell-cycle-regulatory gatekeeper and genome-stabilizing caretaker tumor suppressor genes, respectively. These differential quantifications of tumor dysfunction may in turn be used to create a tumor-specific 'periodic table' that guides rational formulation of survival-enhancing anticancer treatment strategies.

  13. Electricity privatisation

    International Nuclear Information System (INIS)

    Dobson, Frank; Skinner, Dennis; Marshall, John

    1990-01-01

    In this amendment debate about the privatisation of the electricity supply, the opposition develops a number of themes detracting from the government's policy in this matter. It is felt that the industry is being sold off much too cheaply, at about one third of its value based on previous audits. Measures to prevent environmental damage are not likely to be implemented as they would reduce profits. Fuel reserves are in danger of depletion, especially natural gas. Coal imports will increase with accompanying threats to the balance of payments. Lastly, it is argued that very large sums of money are being paid unnecessarily to City Analysts and that big business and M.P.s are acting immorally in extracting money from what should be a publicly owned utility. The amendment was defeated by 298 to 186. (author)

  14. Common issues concerning electric power and gas

    International Nuclear Information System (INIS)

    1996-01-01

    EDF and GDF, the French government owned electric power and gas utilities have jointly decided to improve their employment and employee situation with the hiring of 11000 to 15000 young people for a 3-year period and the reduction of the working hours. A european disagreement is to be judged concerning electric power and gas import and export monopolies in several european countries

  15. Atmospheric Electricity and Tethered Aerostats, Volume 1

    Science.gov (United States)

    1976-05-11

    CATALOG NUMBER AFETR -TR-76-07 __ 4. TITLE (and Subtitle) -. TYPE OF REPORT & PERIOD COVERED ATMOSPHERIC ELECTRICITY AND TETHERED AEROSTATS, FINAL. 1...Electricity Faraday Capes Balloons Lightning Effects , Protection, Warning Systems Conducting and Non-Conducting ’Tethers Potential Geadient Anomalies...and identifying feasible protective systems. After a brief introductory section math models of effects of tethered balloons on surrounding

  16. Search for a neutron electric dipole moment

    Energy Technology Data Exchange (ETDEWEB)

    Morse, J [Rutherford Appleton Laboratory, Chilton (U.K.)

    1984-03-01

    To search for evidence of a breakdown of symmetry under the time reversal transformation, a magnetic resonance measurement is made to detect an electric dipole moment (EDM) of ultracold neutrons stored for periods approximately= 60s in the presence of a strong electric field. The measured neutron EDM is (0.3 +- 4.8) x 10/sup -25/ ecm.

  17. Electricity supply and demand analysis in electric system of Uruguay 2000-2007 period

    International Nuclear Information System (INIS)

    2008-01-01

    This article is about the following topics: energy analysis, production and use, supply and demand, energy consumption evolution, energy sources, energy demand by economic sector between years 2000-2007, energy range, energy growing rate, demanding maximum power, growing maximum rate, exported and imported energy.

  18. Carbon pricing, nuclear power and electricity markets

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, R.; Keppler, J. H. [OECD Nuclear Energy Agency, 12, boulevard des Iles, 92130 Issy-les-Moulineaux (France)

    2012-07-01

    In 2010, the NEA in conjunction with the International Energy Agency produced an analysis of the Projected Costs of Electricity for almost 200 power plants, covering nuclear, fossil fuel and renewable electricity generation. That analysis used lifetime costs to consider the merits of each technology. However, the lifetime cost analysis is less applicable in liberalised markets and does not look specifically at the viewpoint of the private investor. A follow-up NEA assessment of the competitiveness of nuclear energy against coal- and gas-fired generation under carbon pricing has considered just this question. The economic competition in electricity markets is today between nuclear energy and gas-fired power generation, with coal-fired power generation not being competitive as soon as even modest carbon pricing is introduced. Whether nuclear energy or natural gas comes out ahead in their competition depends on a number of assumptions, which, while all entirely reasonable, yield very different outcomes. The analysis in this study has been developed on the basis of daily data from European power markets over the last five-year period. Three different methodologies, a Profit Analysis looking at historic returns over the past five years, an Investment Analysis projecting the conditions of the past five years over the lifetime of plants and a Carbon Tax Analysis (differentiating the Investment Analysis for different carbon prices) look at the issue of competitiveness from different angles. They show that the competitiveness of nuclear energy depends on a number of variables which in different configurations determine whether electricity produced from nuclear power or from CCGTs generates higher profits for its investors. These are overnight costs, financing costs, gas prices, carbon prices, profit margins (or mark-ups), the amount of coal with carbon capture and electricity prices. This paper will present the outcomes of the analysis in the context of a liberalised

  19. Carbon pricing, nuclear power and electricity markets

    International Nuclear Information System (INIS)

    Cameron, R.; Keppler, J. H.

    2012-01-01

    In 2010, the NEA in conjunction with the International Energy Agency produced an analysis of the Projected Costs of Electricity for almost 200 power plants, covering nuclear, fossil fuel and renewable electricity generation. That analysis used lifetime costs to consider the merits of each technology. However, the lifetime cost analysis is less applicable in liberalised markets and does not look specifically at the viewpoint of the private investor. A follow-up NEA assessment of the competitiveness of nuclear energy against coal- and gas-fired generation under carbon pricing has considered just this question. The economic competition in electricity markets is today between nuclear energy and gas-fired power generation, with coal-fired power generation not being competitive as soon as even modest carbon pricing is introduced. Whether nuclear energy or natural gas comes out ahead in their competition depends on a number of assumptions, which, while all entirely reasonable, yield very different outcomes. The analysis in this study has been developed on the basis of daily data from European power markets over the last five-year period. Three different methodologies, a Profit Analysis looking at historic returns over the past five years, an Investment Analysis projecting the conditions of the past five years over the lifetime of plants and a Carbon Tax Analysis (differentiating the Investment Analysis for different carbon prices) look at the issue of competitiveness from different angles. They show that the competitiveness of nuclear energy depends on a number of variables which in different configurations determine whether electricity produced from nuclear power or from CCGTs generates higher profits for its investors. These are overnight costs, financing costs, gas prices, carbon prices, profit margins (or mark-ups), the amount of coal with carbon capture and electricity prices. This paper will present the outcomes of the analysis in the context of a liberalised

  20. A smooth transition logit model of the effects of deregulation in the electricity market

    DEFF Research Database (Denmark)

    Hurn, A. Stan; Silvennoinen, Annastiina; Teräsvirta, Timo

    2016-01-01

    of the model are derived along with their asymptotic properties, together with a Lagrange multiplier test of the null hypothesis of linearity in the underlying latent index. The development of the STL model is motivated by the desire to assess the impact of deregulation in the Queensland electricity market...... and ascertain whether increased competition has resulted in significant changes in the behaviour of the spot price of electricity, specifically with respect to the occurrence of periodic abnormally high prices. The model allows the timing of any change to be endogenously determined and also market participants...

  1. TEP Power Partners Project [Tucson Electric Power

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2014-02-06

    The Arizona Governor’s Office of Energy Policy, in partnership with Tucson Electric Power (TEP), Tendril, and Next Phase Energy (NPE), formed the TEP Power Partners pilot project to demonstrate how residential customers could access their energy usage data and third party applications using data obtained from an Automatic Meter Reading (AMR) network. The project applied for and was awarded a Smart Grid Data Access grant through the U.S. Department of Energy. The project participants’ goal for Phase I is to actively engage 1,700 residential customers to demonstrate sustained participation, reduction in energy usage (kWh) and cost ($), and measure related aspects of customer satisfaction. This Demonstration report presents a summary of the findings, effectiveness, and customer satisfaction with the 15-month TEP Power Partners pilot project. The objective of the program is to provide residential customers with energy consumption data from AMR metering and empower these participants to better manage their electricity use. The pilot recruitment goals included migrating 700 existing customers from the completed Power Partners Demand Response Load Control Project (DRLC), and enrolling 1,000 new participants. Upon conclusion of the project on November 19, 2013; 1,390 Home Area Networks (HANs) were registered; 797 new participants installed a HAN; Survey respondents’ are satisfied with the program and found value with a variety of specific program components; Survey respondents report feeling greater control over their energy usage and report taking energy savings actions in their homes after participating in the program; On average, 43 % of the participants returned to the web portal monthly and 15% returned weekly; and An impact evaluation was completed by Opinion Dynamics and found average participant savings for the treatment period1 to be 2.3% of their household use during this period.2 In total, the program saved 163 MWh in the treatment period of 2013.

  2. Current status of and problems in ice heat storage systems contribution to improving load rate. Contracts on Eco-Ice reached 240 cases by October 1997, an increase of 1.5 times over the same period of the previous year (Chubu Electric Power Co. Inc.); Fukaritsu kaizen ni kokensuru kori chikunetsu system no genjo to kadai. 1997 nendo 10 gatsu made no ekoaisu seiyaku wa 240 ken de tai zennen dokihi 1.5bai (Chubu Denryoku)

    Energy Technology Data Exchange (ETDEWEB)

    Urata, M. [Chubu Electric Power Co. Inc., Nagoya (Japan)

    1998-02-01

    This paper introduces activities performed by Chubu Electric Power Co., Inc. on ice heat storage air conditioning systems. Chubu Electric Power has worked with concerted efforts particularly on proliferation of an ice heat storage type air conditioning system, called `Eco-Ice`. A `heat storage air conditioner group` has been established in the sales department of the head office, and `market development groups` in branch offices to advance the recommendation activities. The Eco-Ice has been publicized on TV commercials, and the `97 Electric Power Heat Storage Air Conditioning Fair was held. Individual discrete type models were added to the product line-up in fiscal 1995. In addition, because of the system economy having been improved as a result of the improvements in the governmental subsidy system, power charge system, and support system, the number of Eco-Ice contracts is increasing rapidly. Two-hundred and forty Eco-Ice systems were contracted from April to October 1997, which means that peak shift capacity reached 7887 kW. Compared with the same period of fiscal 1996, the number of contract increased by 74 cases or 45% , and the peak shift capacity increased by 3148 kW or 66%. 4 figs.

  3. Electricity sector reform in Greece

    International Nuclear Information System (INIS)

    Iliadou, Ekaterini N.

    2009-01-01

    This paper provides an outlook of the electricity market reform in Greece which started in 2001 and is still developing slowly. This is related to the persisting dominance of the incumbent company and the specificities of the electricity sector of Greece which is heavily dependent on indigenous lignite firing generation, while being located in the periphery of the EU internal electricity and gas markets. Competition through enhancing electricity trade in the region is limited to date, as the establishment of an internal market in South East Europe also progresses slowly. Development of competition through gas-firing generation by new entrants has been the priority adopted by State and Regulator's policies. However, the gas supply market in Greece and in the region still lags behind. (author)

  4. Profiling a Periodicals Collection

    Science.gov (United States)

    Bolgiano, Christina E.; King, Mary Kathryn

    1978-01-01

    Libraries need solid information upon which to base collection development decisions. Specific evaluative methods for determining scope, access, and usefullness are described. Approaches used for data collection include analysis of interlibrary loan requests, comparison with major bibliographies, and analysis of accessibility through available…

  5. Overview of hybrid electric vehicle trend

    Science.gov (United States)

    Wang, Haomiao; Yang, Weidong; Chen, Yingshu; Wang, Yun

    2018-04-01

    With the increase of per capita energy consumption, environmental pollution is worsening. Using new alternative sources of energy, reducing the use of conventional fuel-powered engines is imperative. Due to the short period, pure electric vehicles cannot be mass-produced and there are many problems such as imperfect charging facilities. Therefore, the development of hybrid electric vehicles is particularly important in a certain period. In this paper, the classification of hybrid vehicle, research status of hybrid vehicle and future development trends of hybrid vehicles is introduced. It is conducive to the public understanding of hybrid electric vehicles, which has a certain theoretical significance.

  6. Polysheroidal periodic functions

    International Nuclear Information System (INIS)

    Truskova, N.F.

    1985-01-01

    Separation of variables in the Helmholtz N-dimensional (N≥4) equation in polyspheroidal coordinate systems leads to the necessity of solving equations going over into equations for polyspheroidal periodic functions used for solving the two-centre problem in quantum mechanics, the three-body problem with Coulomb interaction, etc. For these functions the expansions are derived in terms of the Jacobi polynomials and Bessel functions. Their basic properties, asymptotics are considered. The algorithm of their computer calculations is developed. The results of numerical calculations are given

  7. Deciphering Periodic Methanol Masers

    Science.gov (United States)

    Stecklum, Bringfried; Caratti o Garatti, Alessio; Henning, Thomas; Hodapp, Klaus; Hopp, Ulrich; Kraus, Alex; Linz, Hendrik; Sanna, Alberto; Sobolev, Andrej; Wolf, Verena

    2018-05-01

    Impressive progress has been made in recent years on massive star formation, yet the involved high optical depths even at submm/mm wavelengths make it difficult to reveal its details. Recently, accretion bursts of massive YSOs have been identified to cause flares of Class II methanol masers (methanol masers for short) due to enhanced mid-IR pumping. This opens a new window to protostellar accretion variability, and implies that periodic methanol masers hint at cyclic accretion. Pinning down the cause of the periodicity requires joint IR and radio monitoring. We derived the first IR light curve of a periodic maser host from NEOWISE data. The source, G107.298+5.639, is an intermediate-mass YSO hosting methanol and water masers which flare every 34.5 days. Our recent joint K-band and radio observations yielded first but marginal evidence for a phase lag between the rise of IR and maser emission, respectively, and revealed that both NEOWISE and K-band light curves are strongly affected by the light echo from the ambient dust. Both the superior resolution of IRAC over NEOWISE and the longer wavelengths compared to our ground-based imaging are required to inhibit the distractive contamination by the light echo. Thus, we ask for IRAC monitoring of G107 to cover one flare cycle, in tandem with 100-m Effelsberg and 2-m Wendelstein radio and NIR observations to obtain the first high-quality synoptic measurements of this kind of sources. The IR-maser phase lag, the intrinsic shape of the IR light curves and their possible color variation during the cycle allow us to constrain models for the periodic maser excitation. Since methanol masers are signposts of intermediate-mass and massive YSOs, deciphering their variability offers a clue to the dynamics of the accretion-mediated growth of massive stars and their feedback onto the immediate natal environment. The Spitzer light curve of such a maser-hosting YSO would be a legacy science product of the mission.

  8. Digital control of electric drives

    CERN Document Server

    Koziol, R; Szklarski, L

    1992-01-01

    The electromechanical systems employed in different branches of industry are utilized most often as drives of working machines which must be fed with electric energy in a continuous, periodic or even discrete way. Some of these machines operate at constant speed, others require wide and varying energy control. In many designs the synchronous cooperation of several electric drives is required in addition to the desired dynamic properties. For these reasons the control of the cooperation and dynamics of electromechanical systems requires the use of computers.This book adopts an unusual approach

  9. Electrical equipment design library

    International Nuclear Information System (INIS)

    1994-01-01

    This book guides the design supervision, construction order for electrical equipment. The contents of this library are let's use electricity like this, leading-in-pole and casual power, electric pole install below 300KVA, electric pole install below 301∼1000KVA, electric pole install exceed 1000KVA, rooftop install exceed 1000KVA, CUBICLE type, 154KV services. It adds an appendix.

  10. Pricing of electricity in Indonesia

    International Nuclear Information System (INIS)

    Amarullah, M.

    1983-01-01

    The objectives of this study are 1) to establish a sound theoretical basis for the determinants of electricity demand in Indonesia, 2) to measure the welfare losses of existing electricity pricing, and 3) to suggest a method of reducing these welfare losses. An econometric model for electricity demand is estimated using pooled time-series of fifteen regions in Indonesia covering the period 1970-1979. The short run price elasticities for both residential and industrial/business sectors are found to be inelastic, while the long run price elasticities for these sectors are found to be quite elastic with a value of -.61 for the residential sector and of -1.1 for the industrial/business sector. Income elasticity is .8 in the short run and around 1.00 for the long run. The exposure variable that captures the accessibility of electricity, has long run elasticity of 1.00 for the residential sector and less than 1.00 for the industrial/business sector. Due to distributional considerations, the 1980's electricity rate was set below its efficient level, and has created a welfare loss of Rp.8273.23 million per month. This accounts for 36.03% of the monthly electricity revenue. A rebate mechanism is recommended in this study, which provides a way to mitigate conflicting aspects of efficiency and equity

  11. New options for purchasing electricity

    International Nuclear Information System (INIS)

    2003-10-01

    This guide is intended for small to medium commercial customers in Alberta and explains new options for purchasing electricity. Small to medium customers include corner stores, community centres, schools, small office buildings, and light industrial businesses. In the 1990s, private power producers in Alberta built 3,000 megawatts of new generation, adding 30 per cent more supply to the power grid in the province. Prices in the deregulated electricity market have fluctuated with natural gas prices, changing weather and changing power demands. The competitive electricity market was opened on January 1, 2001 in Alberta, offering consumers purchasing choices such as green power, multi-year contracts, or electricity rates under the Regulated Rate Option (RRO). The RRO was a transition mechanism that will end by December 31, 2003 at which time, small to medium commercial customers will have the option to shop around for competitive electricity contracts that provide a fixed price of power over time, or they can opt to stay with their current supplier and receive a regulated flow-through of market prices. Under the flow-through option, risk of future deferral charges is reduced, but electricity prices will probably change between billing periods. 1 fig

  12. Reference costs of the electric power production

    International Nuclear Information System (INIS)

    2003-06-01

    This study periodically realized by the DGEMP aims to compare the competitiveness of the different channels of electric power production, for different utilization conditions. The first part ''reference costs of the 2003 electric power production'' examines the prices of the electric power produced by different channels in particular in the framework of the industrial implementing in 2015. The nuclear and thermal power plants are concerned. The second part is devoted to the decentralized production channels (wind energy, photovoltaic, cogeneration heat-electricity) is under construction and will be presented next year. (A.L.B.)

  13. Exploring utility organization electricity generation, residential electricity consumption, and energy efficiency: A climatic approach

    International Nuclear Information System (INIS)

    Craig, Christopher A.; Feng, Song

    2017-01-01

    Highlights: • Study examined impact of electricity fuel sources and consumption on emissions. • 97.2% of variability in emissions explained by coal and residential electricity use. • Increasing cooling degree days significantly related to increased electricity use. • Effectiveness of state-level energy efficiency programs showed mixed results. - Abstract: This study examined the impact of electricity generation by fuel source type and electricity consumption on carbon emissions to assess the role of climatic variability and energy efficiency (EE) in the United States. Despite high levels of greenhouse gas emissions, residential electricity consumption continues to increase in the United States and fossil fuels are the primary fuel source of electricity generation. 97.2% of the variability in carbon emissions in the electricity industry was explained by electricity generation from coal and residential electricity consumption. The relationships between residential electricity consumption, short-term climatic variability, long-term climatic trends, short-term reduction in electricity from EE programs, and long-term trends in EE programs was examined. This is the first study of its nature to examine these relationships across the 48 contiguous United States. Inter-year and long-term trends in cooling degree days, or days above a baseline temperature, were the primary climatic drivers of residential electricity consumption. Cooling degree days increased across the majority of the United States during the study period, and shared a positive relationship with residential electricity consumption when findings were significant. The majority of electricity reduction from EE programs was negatively related to residential electricity consumption where findings were significant. However, the trend across the majority of states was a decrease in electricity reduction from EE while residential electricity consumption increased. States that successfully reduced consumption

  14. Effects of electric stimulation of the hunger center in the lateral hypothalamus on slow electric activity and spike activity of fundal and antral stomach muscles in rabbits under conditions of hunger and satiation.

    Science.gov (United States)

    Kromin, A A; Zenina, O Yu

    2013-09-01

    In chronic experiments on rabbits, the effect of electric stimulation of the hunger center in the lateral hypothalamus on myoelectric activity of the fundal and antral parts of the stomach was studied under conditions of hunger and satiation in the absence of food. Stimulation of the lateral hypothalamus in rabbits subjected to 24-h food deprivation and in previously fed rabbits produced incessant seeking behavior, which was followed by reorganization of the structure of temporal organization of slow wave electric activity of muscles of the stomach body and antrum specific for hungry and satiated animals. Increased hunger motivation during electric stimulation of the lateral hypothalamus manifested in the structure of temporal organization of slow wave electric activity of the stomach body and antrum muscles in rabbits subjected to 24-h food deprivation in the replacement of bimodal distribution of slow wave periods to a trimodal type typical of 2-day deprivation, while transition from satiation to hunger caused by electric stimulation of the lateral hypothalamus was associated with a shift from monomodal distributions of slow wave periods to a bimodal type typical of 24-h deprivation. Reorganization of the structure of temporal organization of slow wave electric activity of the stomach body and antrum muscles during electric stimulation of the lateral hypothalamus was determined by descending inhibitory influences of food motivational excitation on activity of the myogenic pacemaker of the lesser curvature of the stomach.

  15. Exploring the relationship between agricultural electricity consumption and output: New evidence from Turkish regional data

    International Nuclear Information System (INIS)

    Dogan, Eyup; Sebri, Maamar; Turkekul, Berna

    2016-01-01

    This study investigates the relationship between agricultural electricity consumption and agricultural output for a panel of 12 regions of Turkey for the period 1995–2013. In order to reveal the possible heterogeneity between regions, empirical analyses are conducted for the whole panel data and two sub-groups within the panel data; namely, coastal regions and non-coastal regions. The results from several panel unit root tests indicate that electricity consumption and output are stationary process at their levels for overall panel and the two specific groups. By using the OLS with regional fixed effects, this study finds that coefficient estimate of electricity consumption on output is statistically significant and positive for overall regions, coastal regions and non-coastal regions. In addition, the results from the Dumitrescu-Hurlin Granger causality test show that there is unidirectional causality running from agricultural output to electricity consumption for non-coastal regions, and there is bidirectional causality between agricultural electricity consumption and output for overall panel and coastal regions. Findings and policy implications are further discussed. - Highlights: •This study uses the recently developed Dumitrescu-Hurlin Granger causality test. •There is unidirectional causality running from agricultural output to electricity consumption for non-coastal regions. •Bidirectional causality runs between the analyzed variables for coastal regions. •Electricity consumption increases agricultural output.

  16. What happened to efficiency in electricity industries after reforms?

    International Nuclear Information System (INIS)

    Erdogdu, Erkan

    2011-01-01

    The last two decades have witnessed widespread power market reforms in both developed and developing countries that have cost billions of dollars. Among the key aims (and assumptions) of these reforms, there has always been realization of improvements in power sector efficiency. This paper questions the validity of this hypothesis. Using panel data from 92 countries covering the period 1982-2008, empirical models are developed and analyzed. The research findings suggest that the impact of the reforms on electricity industry performance is statistically significant but also limited. The results imply that, after controlling for country-specific variables, application of liberal market models in electricity industries slightly increases efficiency in power sector. Besides, we detect a positive relationship between reform process and the percentage share of network (transmission and distribution) losses in total electricity supplied, meaning that as countries take more reform steps the network losses as a fraction of power generated tend to increase. Moreover, the study puts forward that income level and other country specific features are more important determinants of industry efficiency than the reform process. Overall, contrary to expectations of substantial increases in sector efficiency, the paper concludes that introducing a decentralized market model with competition in the electricity sector has a limited increasing effect on power industry performance. - Highlights: → The paper questions whether the reforms increase efficiency in the power sector. → Panel data from 92 countries covering the period 1982-2008 are employed. → Models are developed by fixed/random effect panel data estimation methods. → The paper concludes the reforms have a limited effect on the industry performance. → We also find that as countries take more reform steps the network losses increase.

  17. Electricity fuel contracting

    International Nuclear Information System (INIS)

    Palmer, Karen; Simpson, David; Toman, Michael; Fox-Penner, Peter

    1993-01-01

    The growth of competition in the electricity generation industry, along with changes in natural gas and coal regulation have led to renewed interest in the nature of efficient transactional arrangements for procuring coal and gas. This study examines the evolution of major influences on the incentives for choosing among different transactional forms. We find that the asset specificity hypothesis continues to be an important explanation for transactional arrangements in fuel acquisition. The degree of asset specificity in a fuel supply arrangement is a function of technological factors, of inherent market characteristics and of regulatory rules. The expanding role of more flexible fuel supply arrangements in gas and, to a lesser extent, coal markets is a natural response to current regulatory and technological trends

  18. The Electric Car Challenge.

    Science.gov (United States)

    Diehl, Brian E.

    1997-01-01

    Describes the Electric Car Challenge during which students applied methods of construction to build lightweight, strong vehicles that were powered by electricity. The activity required problem solving, sheet metal work, electricity, design, and construction skills. (JOW)

  19. Electrical Methods: Resistivity Methods

    Science.gov (United States)

    Surface electrical resistivity surveying is based on the principle that the distribution of electrical potential in the ground around a current-carrying electrode depends on the electrical resistivities and distribution of the surrounding soils and rocks.

  20. Controlling Electrical Hazards

    National Research Council Canada - National Science Library

    1997-01-01

    ...). In general, OSHA's electrical standards are based on the National Fire Protection Associations Standard NFPA 70E, Electrical Safety Requirements for Employee Workplaces, and in turn, from the National Electrical Code (NEC...

  1. Agricultural Electricity. Electric Motors. Student Manual.

    Science.gov (United States)

    Benson, Robert T.

    Addressed to the student, this manual, which includes supplementary diagrams, discusses the following topics and principles: Electromagnetic fields, electromagnets, parts of an electric motor, determining speed of an electric motor, types of electric motors in common use (split-phase, capacitor, repulsion-induction, three-phase), the electric…

  2. Prices on electricity and transmission of electricity

    International Nuclear Information System (INIS)

    2003-01-01

    This publication contains data on prices of electric energy and transmission of electricity valid from 1 January 2003. The purpose is to illustrate the price changes on the electricity market in terms of prices for different customer categories. All companies holding network concessions for areas and all companies trading in electricity are included in this report, which is produced on an annual basis.The prices for transmission services 1 January 2003 were on the whole unchanged compared to the preceding year. For households the mean annual cost was SEK 882 for flats, SEK 4 335 for one- or two-family houses with electric heating and SEK 1 925 for those without electric heating. Electricity prices rose considerably on 1 January 2003 compared to the year before. The mean price per kWh for households with standard agreements was SEK 0.519 for deliveries to flats, SEK 0.447 for one- or two-family houses with electric heating and SEK 0.471 without electric heating. As a result, the mean annual cost increased by SEK 326 for flats, SEK 3 012 for one- or two-family houses with electric heating, and by SEK 774 for those houses without electric heating. The high costs of electricity may be explained in part by the development on the Nordic Power Exchange (Nord Pool), where the spot price increased by about 290 per cent during 2002 (1 USD is about 8 SEK)

  3. Periodically modulated dark states

    Science.gov (United States)

    Han, Yingying; Zhang, Jun; Zhang, Wenxian

    2018-04-01

    Phenomena of electromagnetically induced transparency (PEIT) may be interpreted by the Autler-Townes Splitting (ATS), where the coupled states are split by the coupling laser field, or by the quantum destructive interference (QDI), where the atomic phases caused by the coupling laser and the probe laser field cancel. We propose modulated experiments to explore the PEIT in an alternative way by periodically modulating the coupling and the probe fields in a Λ-type three-level system initially in a dark state. Our analytical and numerical results rule out the ATS interpretation and show that the QDI interpretation is more appropriate for the modulated experiments. Interestingly, dark state persists in the double-modulation situation where control and probe fields never occur simultaneously, which is significant difference from the traditional dark state condition. The proposed experiments are readily implemented in atomic gases, artificial atoms in superconducting quantum devices, or three-level meta-atoms in meta-materials.

  4. Plug-in electric vehicles integrating fluctuating renewable electricity

    Energy Technology Data Exchange (ETDEWEB)

    Dallinger, David

    2013-11-01

    This paper examines a method to model plug-in electric vehicles as part of the power system and presents results for the contribution of plug-in electric vehicles to balance the fluctuating electricity generation of renewable energy sources. The scientific contribution includes: - A novel approach to characterizing fluctuating generation. This allows the detailed comparison of results from energy analysis and is the basis to describe the effect of electricity from renewable energy sources and plug-in electric vehicles on the power system. - The characterization of mobile storage, which includes the description of mobility behavior using probabilities and battery discharging costs. - The introduction of an agent-based simulation approach, coupling energy markets and distributed grids using a price-based mechanism design. - The description of an agent with specific driving behavior, battery discharging costs and optimization algorithm suitable for real plug-in vehicles and simulation models. - A case study for a 2030 scenario describing the contribution of plug-in electric vehicles to balance generation from renewable energy sources in California and Germany.

  5. Feasibility of Colliding-beam fast-fission reactor via 238U80++238 U80+ --> 4 FF + 5n + 430 MeV beam with suppressed plutonium and direct conversion of fission fragment (FF) energy into electricity and/or Rocket propellant with high specific impulse

    Science.gov (United States)

    Maglich, Bogdan; Hester, Tim; Calsec Collaboration

    2015-10-01

    Uranium-uranium colliding beam experiment1, used fully ionized 238U92+ at energy 100GeV --> accelerated through 3 MV accelerator, will collide beam 240 MeV --> 4 FF + 5n + 430 MeV. Using a simple model1 fission σf ~ 100 b. Suppression of Pu by a factor of 106 will be achieved because NO thermal neutron fission can take place; only fast, 1-3 MeV, where σabs is negligible. Direct conversion of 95% of 430 MeV produced is carried by electrically charged FFs which are magnetically funneled for direct conversion of energy of FFs via electrostatic decelerators4,11. 90% of 930 MeV is electrically recoverable. Depending on the assumptions, we project electric _ power density production of 20 to 200 MWe m-3, equivalent to Thermal 1.3 - 13 GWthm-3. If one-half of unburned U is used for propulsion while rest powers system, heavy FF ion mass provides specific impulse Isp = 106 sec., 103 times higher than current rocket engines.

  6. Electrical engineer's reference book

    CERN Document Server

    Laughton, M A

    1985-01-01

    Electrical Engineer's Reference Book, Fourteenth Edition focuses on electrical engineering. The book first discusses units, mathematics, and physical quantities, including the international unit system, physical properties, and electricity. The text also looks at network and control systems analysis. The book examines materials used in electrical engineering. Topics include conducting materials, superconductors, silicon, insulating materials, electrical steels, and soft irons and relay steels. The text underscores electrical metrology and instrumentation, steam-generating plants, turbines

  7. DOE handbook electrical safety

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    Electrical Safety Handbook presents the Department of Energy (DOE) safety standards for DOE field offices or facilities involved in the use of electrical energy. It has been prepared to provide a uniform set of electrical safety guidance and information for DOE installations to effect a reduction or elimination of risks associated with the use of electrical energy. The objectives of this handbook are to enhance electrical safety awareness and mitigate electrical hazards to employees, the public, and the environment.

  8. Electrical safety guidelines

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The Electrical Safety Guidelines prescribes the DOE safety standards for DOE field offices or facilities involved in the use of electrical energy. It has been prepared to provide a uniform set of electrical safety standards and guidance for DOE installations in order to affect a reduction or elimination of risks associated with the use of electrical energy. The objectives of these guidelines are to enhance electrical safety awareness and mitigate electrical hazards to employees, the public, and the environment.

  9. Aversive olfactory associative memory loses odor specificity over time.

    Science.gov (United States)

    König, Christian; Antwi-Adjei, Emmanuel; Ganesan, Mathangi; Kilonzo, Kasyoka; Viswanathan, Vignesh; Durairaja, Archana; Voigt, Anne; Yarali, Ayse

    2017-05-01

    Avoiding associatively learned predictors of danger is crucial for survival. Aversive memories can, however, become counter-adaptive when they are overly generalized to harmless cues and contexts. In a fruit fly odor-electric shock associative memory paradigm, we found that learned avoidance lost its specificity for the trained odor and became general to novel odors within a day of training. We discuss the possible neural circuit mechanisms of this effect and highlight the parallelism to over-generalization of learned fear behavior after an incubation period in rodents and humans, with due relevance for post-traumatic stress disorder. © 2017. Published by The Company of Biologists Ltd.

  10. Comparative assessment of electricity generation options in the Philippines

    International Nuclear Information System (INIS)

    Leonin, T.V.; Mundo, M.Q.; Venida, L.L.; Arriola, H.; Madrio, E.

    2001-01-01

    The development of a country specific data base on energy sources, facilities and technologies is presented in this paper. It also identified feasible national electricity generating options and electric power system expansion alternatives for the period 2000-2020, and conducted comparative assessments of these options based on economic and environmental considerations. The possible role of nuclear power in the country's future electric energy was also studied. The comparison of three electricity generating options were considered: coal-fired thermal power plant without flue gas desulfurization (FGD), coal-fired thermal power plant with FGD and combined cycle power plant with 300 MW generating capacity each. Based on the analysis of three alternatives, the use of coal-fired power plants equipped with flue gas desulfurization (FGD) should be seriously considered. The government is expected to pursue the full development of local energy sources such as hydropower, geothermal, coal, natural gas and other new and renewable energy sources. However, there will still be a major need for imported oil and coal fuel which will likely supply unidentified energy sources beyond 2010. In the case of nuclear power, the government has not firmed up definite plans for any construction of nuclear power plants after 2010. However, the long term energy development plan still includes the operation of at least two nuclear power plants by the 2020 and this long term range program has not been revised in the recent published updates. (Author)

  11. Topics on electricity trade

    International Nuclear Information System (INIS)

    Skytte, K.

    2001-01-01

    The first chapter in this thesis is a survey of studies on electricity trade, which has been included in order to show how subjects in this thesis fit into this aspect of energy research. Transitions from centralised monopolies to liberalised electricity markets have been inaugurated in the northern European countries during the last decade. The backgrounds and speed of transitions differ within the countries. Where Norway liberalised its electricity market in order to stabilise the prices, EU urged a liberalisation in order to make the electricity supply industry more effective. Together with national liberalisation, the opening of the cross border trade between the countries is also urged. The first paper in this thesis describes those different liberalisation processes within northern Europe and discusses problems that may arise in a transition period for integrating the countries into a common electricity market with efficient cross-border competition. Before the liberalisation process started, the electricity generation was determined by a central load dispatch at known prices. The introduction of competition has necessitated the creation of new competitive markets, power exchanges and financial markets where generation and prices are determined by demand and supply on the markets. One implication of this is that investments in new plants shall be made under levels of uncertainty about future prices. The second paper in this thesis analyses the importance of introducing uncertainty in energy-economic modelling of the electricity supply sector. Another implication, which arises on introducing a new market structure and power exchanges, is that the design of the power exchanges influences the price setting on the markets. The third paper of this thesis analyses the price setting on the regulating power market on the Nordic power exchange Nord Pool. More precisely, the paper reveals the pattern of the prices on the regulating power market by analysing the cost of

  12. Topics on electricity trade

    Energy Technology Data Exchange (ETDEWEB)

    Skytte, K.

    2001-07-01

    The first chapter in this thesis is a survey of studies on electricity trade, which has been included in order to show how subjects in this thesis fit into this aspect of energy research. Transitions from centralised monopolies to liberalised electricity markets have been inaugurated in the northern European countries during the last decade. The backgrounds and speed of transitions differ within the countries. Where Norway liberalised its electricity market in order to stabilise the prices, EU urged a liberalisation in order to make the electricity supply industry more effective. Together with national liberalisation, the opening of the cross border trade between the countries is also urged. The first paper in this thesis describes those different liberalisation processes within northern Europe and discusses problems that may arise in a transition period for integrating the countries into a common electricity market with efficient cross-border competition. Before the liberalisation process started, the electricity generation was determined by a central load dispatch at known prices. The introduction of competition has necessitated the creation of new competitive markets, power exchanges and financial markets where generation and prices are determined by demand and supply on the markets. One implication of this is that investments in new plants shall be made under levels of uncertainty about future prices. The second paper in this thesis analyses the importance of introducing uncertainty in energy-economic modelling of the electricity supply sector. Another implication, which arises on introducing a new market structure and power exchanges, is that the design of the power exchanges influences the price setting on the markets. The third paper of this thesis analyses the price setting on the regulating power market on the Nordic power exchange Nord Pool. More precisely, the paper reveals the pattern of the prices on the regulating power market by analysing the cost of

  13. Electrical storm: clinical manifestations and management.

    Science.gov (United States)

    Littmann, L; Rennyson, S L

    2007-10-01

    Electrical storm is the clustering of hemodynamically destabilizing ventricular tachycardia or ventricular fibrillation that typically requires multiple electrical cardioversions or defibrillations within a 24-hour period. Electrical storm is frequently seen in the acute phase of myocardial infarction, in patients with the genetic arrhythmia syndromes, and in patients with implanted cardioverters-defibrillators. The evaluation and management should focus on the immediate suppression of the arrhythmia, a search for possible reversible causes, and attempts to prevent recurrences. In this review we present the most common conditions associated with electrical storm, therapeutic options for suppression of electrical storm, and new investigational techniques emerging for the treatment of electrical storm in refractory cases. The management of this life threatening arrhythmia typically requires the coordinated efforts of emergency medicine, critical care, cardiology, cardiac electrophysiology, and pacemaker experts.

  14. Forecasting residential electricity demand in provincial China.

    Science.gov (United States)

    Liao, Hua; Liu, Yanan; Gao, Yixuan; Hao, Yu; Ma, Xiao-Wei; Wang, Kan

    2017-03-01

    In China, more than 80% electricity comes from coal which dominates the CO2 emissions. Residential electricity demand forecasting plays a significant role in electricity infrastructure planning and energy policy designing, but it is challenging to make an accurate forecast for developing countries. This paper forecasts the provincial residential electricity consumption of China in the 13th Five-Year-Plan (2016-2020) period using panel data. To overcome the limitations of widely used predication models with unreliably prior knowledge on function forms, a robust piecewise linear model in reduced form is utilized to capture the non-deterministic relationship between income and residential electricity consumption. The forecast results suggest that the growth rates of developed provinces will slow down, while the less developed will be still in fast growing. The national residential electricity demand will increase at 6.6% annually during 2016-2020, and populous provinces such as Guangdong will be the main contributors to the increments.

  15. Electricity spot price dynamics: Beyond financial models

    International Nuclear Information System (INIS)

    Guthrie, Graeme; Videbeck, Steen

    2007-01-01

    We reveal properties of electricity spot prices that cannot be captured by the statistical models, commonly used to model financial asset prices, that are increasingly used to model electricity prices. Using more than eight years of half-hourly spot price data from the New Zealand Electricity Market, we find that the half-hourly trading periods fall naturally into five groups corresponding to the overnight off-peak, the morning peak, daytime off-peak, evening peak, and evening off-peak. The prices in different trading periods within each group are highly correlated with each other, yet the correlations between prices in different groups are lower. Models, adopted from the modeling of security prices, that are currently applied to electricity spot prices are incapable of capturing this behavior. We use a periodic autoregression to model prices instead, showing that shocks in the peak periods are larger and less persistent than those in off-peak periods, and that they often reappear in the following peak period. In contrast, shocks in the off-peak periods are smaller, more persistent, and die out (perhaps temporarily) during the peak periods. Current approaches to modeling spot prices cannot capture this behavior either. (author)

  16. Electric charger for an accumulator or battery

    NARCIS (Netherlands)

    Robers, E.W.J.; Molenaar, B.A.M.; Smit, W.; Bech, L.P.; Bouman, C.

    2009-01-01

    The invention relates to an electric charger for an accumulator or a battery or the like, which is adapted for rapid charging during an on-period and comprises for this purpose control means for starting and ending the on-period. The charger is provided with a circuit for converting a supply voltage

  17. Nigeria electricity crisis: Power generation capacity expansion and environmental ramifications

    International Nuclear Information System (INIS)

    Aliyu, Abubakar Sadiq; Ramli, Ahmad Termizi; Saleh, Muneer Aziz

    2013-01-01

    Access to clean and stable electricity is essential in actualizing Nigeria's quest for joining the league of twenty most industrious nations by the year 2020 (vision 20:2020). No country can develop and sustain it development without having a minimum access to electricity for it larger percentage of its population. At present, Nigeria depends petroleum reserves and its aged hydro plant instalments for electricity generation to feed the 40% of its total population that are connected to the national grid. This paper summarizes literature on the current energy issues in Nigeria and introduces the difficulty of the issues involved. The paper also analyses the current (2010) electricity generation as well as the future expansion plans of the Government in 20 years period. The plan includes the introduction of new electrify generation technologies that have not been in used in the base year (2010). The electricity generation system of (including the future expansion plan) was simulated using the LEAP System (Long-range Energy Alternative and Planning). We also investigated the potential environmental impact of siting a nuclear power plant in one of the potential sites based on the site's specific micro-meteorology (land use) and meteorology using the US EPA (Environmental Protection Agency) models; AERMOD 12345. - Highlights: • This paper scrutinizes literature on Nigeria's energy crisis and presents the policies of the clean technology as solutions. • Only 40% of Nigeria's population is connected to the grid; and this population faces power problems 60% of the time. • Simulation of Nigeria electricity generation system was done. • Air dispersion modellingmodelling for radiological health risk from NPP was done

  18. Swiss electricity production into the future

    International Nuclear Information System (INIS)

    Steinmann, Walter

    2008-01-01

    also involves the un-bundling of the network and energy provision, the cost of network usage and actual electricity consumption will in future have to appear separately on bills. That way customers will know just how much they are paying for the network, how much in charges and how much the electricity itself costs. And along with the Electricity Supply Act, the revised Energy Act was also adopted. It stipulates that energy production from renewable must be increased to at least 5400 gigawatt hours by 2030. The Act envisages targeted measures to promote renewable energies and greater efficiency. The most important instrument is the cost-covering feed-in price for power from renewable energy sources from solar power, biomass, small-scale hydropower and wind. It will ensure a major boost in power from renewable energies from 2009. The Federal Council set further important markers to promote the use of renewable energies and improve energy efficiency in its decision of 20 February 2008. The goals are clear: By 2020 the share of renewable energies in overall energy consumption should be raised by at least 50% from 16.2% today to 24%. The consumption of fossil fuels should be reduced by 20% between 2010 and 2020 and electricity consumption should increase by a maximum of 5% over the same period. The measures that lead to these goals are primarily strengthened instruments such as regulations, standards and bans in the area of appliances, buildings and vehicles. These measures go hand in hand with a strong push in the area of research and in training. In view of the forecasted trends and expected events, regarding electricity demand, the security-related shutdown of the first nuclear power plants in Switzerland around the year 2020 and the concurrent expiry of the long-term delivery contracts for electricity with France, the Federal Council argued for the extension and construction of large-scale power stations (pillar three). Subsequently, the Federal Council evaluated two

  19. Electric engineering introduction

    International Nuclear Information System (INIS)

    An, Byeong Won; Eom, Sang Ho

    1999-03-01

    It is divided into nine chapters, which includes electricity theory such as structure of material and current, nature of electricity, static, magnetic force and magnetic attraction, attraction of current and a storage battery, electric circuit on a direct current circuit, single phase circuit and 3-phase current circuit electricity machine like DC generator, DC motor, alternator, electric transformer, single-phase induction motor, 3-phase induction motor, synchronous motor, synchro electric machine, semiconductor such as diode, transistor, FET, UJT, silicon symmetrical switch, electronic circuit like smoothing circuit and Bistable MV. circuit, automatic control, measurement of electricity, electric application and safety.

  20. Solar/electric heating systems for the future energy system

    DEFF Research Database (Denmark)

    Furbo, Simon; Dannemand, Mark; Perers, Bengt

    elements/heat pump, advanced heat storage tanks and advanced control systems. Heat is produced by solar collectors in sunny periods and by electrical heating elements/heat pump. The electrical heating elements/heat pump will be in operation in periods where the heat demand cannot be covered by solar energy....... The aim is to use the auxiliary heating units when the electricity price is low, e.g. due to large electricity production by wind turbines. The unit is equipped with an advanced control system where the control of the auxiliary heating is based on forecasts of the electricity price, the heat demand...

  1. The EDF catalogue of technical specifications (reference HN), standardization center; Catalogue des specifications techniques EDF (reference HN) centre de normalisation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    A list of EDF technical specifications, valid at the 01/01/1996 date, is presented. Specifications domains such as electrical installations, equipment and materials, uninsulated and insulated conductors, measurement, control and command, electric power generating or transforming equipment, electrical appliances, telecommunications, electronic and computer systems, are covered

  2. [Childhood periodic syndromes].

    Science.gov (United States)

    Cuvellier, J-C; Lépine, A

    2010-01-01

    This review focuses on the so-called "periodic syndromes of childhood that are precursors to migraine", as included in the Second Edition of the International Classification of Headache Disorders. Three periodic syndromes of childhood are included in the Second Edition of the International Classification of Headache Disorders: abdominal migraine, cyclic vomiting syndrome and benign paroxysmal vertigo, and a fourth, benign paroxysmal torticollis is presented in the Appendix. The key clinical features of this group of disorders are the episodic pattern and intervals of complete health. Episodes of benign paroxysmal torticollis begin between 2 and 8 months of age. Attacks are characterized by an abnormal inclination and/or rotation of the head to one side, due to cervical dystonia. They usually resolve by 5 years. Benign paroxysmal vertigo presents as sudden attacks of vertigo, accompanied by inability to stand without support, and lasting seconds to minutes. Age at onset is between 2 and 4 years, and the symptoms disappear by the age of 5. Cyclic vomiting syndrome is characterized in young infants and children by repeated stereotyped episodes of pernicious vomiting, at times to the point of dehydration, and impacting quality of life. Mean age of onset is 5 years. Abdominal migraine remains a controversial issue and presents in childhood with repeated stereotyped episodes of unexplained abdominal pain, nausea and vomiting occurring in the absence of headache. Mean age of onset is 7 years. Both cyclic vomiting syndrome and abdominal migraine are noted for the absence of pathognomonic clinical features but also for the large number of other conditions to be considered in their differential diagnoses. Diagnostic criteria, such as those of the Second Edition of the International Classification of Headache Disorders and the North American Society for Pediatric Gastroenterology, Hepatology and Nutrition, have made diagnostic approach and management easier. Their diagnosis

  3. Nonparametric Inference for Periodic Sequences

    KAUST Repository

    Sun, Ying; Hart, Jeffrey D.; Genton, Marc G.

    2012-01-01

    the periodogram, a widely used tool for period estimation. The CV method is computationally simple and implicitly penalizes multiples of the smallest period, leading to a "virtually" consistent estimator of integer periods. This estimator is investigated both

  4. The Future of Electricity Resource Planning

    Energy Technology Data Exchange (ETDEWEB)

    Kahrl, Fredrich [Energy and Environmental Economics, Inc., San Francisco, CA (United States); Mills, Andrew [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lavin, Luke [Energy and Environmental Economics, Inc., San Francisco, CA (United States); Ryan, Nancy [Energy and Environmental Economics, Inc., San Francisco, CA (United States); Olsen, Arne [Energy and Environmental Economics, Inc., San Francisco, CA (United States); Schwartz, Lisa [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-09-14

    Electricity resource planning is the process of identifying longer-term investments to meet electricity reliability requirements and public policy goals at a reasonable cost. Resource planning processes provide a forum for regulators, electric utilities, and electricity industry stakeholders to evaluate the economic, environmental, and social benefits and costs of different investment options. By facilitating a discussion on future goals, challenges and strategies, resource planning processes often play an important role in shaping utility business decisions. Resource planning emerged more than three decades ago in an era of transition, where declining electricity demand and rising costs spurred fundamental changes in electricity industry regulation and structure. Despite significant changes in the industry, resource planning continues to play an important role in supporting investment decision making. Over the next two decades, the electricity industry will again undergo a period of transition, driven by technological change, shifting customer preferences and public policy goals. This transition will bring about a gradual paradigm shift in resource planning, requiring changes in scope, approaches and methods. Even as it changes, resource planning will continue to be a central feature of the electricity industry. Its functions — ensuring the reliability of high voltage (“bulk”) power systems, enabling oversight of regulated utilities and facilitating low-cost compliance with public policy goals — are likely to grow in importance as the electricity industry enters a new period of technological, economic and regulatory change. This report examines the future of electricity resource planning in the context of a changing electricity industry. The report examines emerging issues and evolving practices in five key areas that will shape the future of resource planning: (1) central-scale generation, (2) distributed generation, (3) demand-side resources, (4

  5. Specifying Specification.

    Science.gov (United States)

    Paulo, Norbert

    2016-03-01

    This paper tackles the accusation that applied ethics is no serious academic enterprise because it lacks theoretical bracing. It does so in two steps. In the first step I introduce and discuss a highly acclaimed method to guarantee stability in ethical theories: Henry Richardson's specification. The discussion shows how seriously ethicists take the stability of the connection between the foundational parts of their theories and their further development as well as their "application" to particular problems or cases. A detailed scrutiny of specification leads to the second step, where I use insights from legal theory to inform the debate around stability from that point of view. This view reveals some of specification's limitations. I suggest that, once specification is sufficiently specified, it appears astonishingly similar to deduction as used in legal theory. Legal theory also provides valuable insight into the functional range of deduction and its relation to other forms of reasoning. This leads to a richer understanding of stability in normative theories and to a smart division of labor between deduction and other forms of reasoning. The comparison to legal theory thereby provides a framework for how different methods such as specification, deduction, balancing, and analogy relate to one another.

  6. Reflections of hunger and satiation in the structure of temporal organization of slow electrical and spike activities of fundal and antral stomach muscles in rabbits.

    Science.gov (United States)

    Kromin, A A; Zenina, O Yu

    2012-11-01

    Manifestations of hunger and satiation in myoelectric activity patterns in different portions of the stomach were studied in chronic experiments. The state of hunger manifested in the structure of temporal organization of slow electric activity of muscles in the stomach body and antrum in the form of bimodal distributions of slow electric wave periods, while satiation as unimodal distribution. In hunger-specific bimodal distribution of slow electric wave periods generated by muscles of the stomach body and antrum, the position of the first maximum carries the information about oncoming food reinforcement, since this particular range of slow wave fluctuations determines temporal parameters of slow electric activity of muscles in all stomach regions in the course of subsequent successive food-procuring behavior. Under conditions of hunger, the pacemaker features of muscles in the lesser curvature are realized incompletely. Complete realization is achieved in the course of food intake and at the state of satiation.

  7. Electricity rationing and public response

    International Nuclear Information System (INIS)

    Souza, Leonardo Rocha; Soares, Lacir Jorge

    2007-01-01

    This paper studies the electricity load demand behavior during the 2001 rationing period, which was implemented because of the Brazilian energy crisis. The hourly data refers to a utility situated in the southeast of the country. We use the model proposed by Soares and Souza [Soares, L.J. and Souza, L.R. (2006), 'Forecasting electricity demand using generalized long memory', International Journal of Forecasting, 22, 17-28.], making use of generalized long memory to model the seasonal behavior of the load. The rationing period is shown to have imposed a structural break in the series, decreasing the load at about 20%. Even so, the forecast accuracy is decreased only marginally, and the forecasts rapidly readapt to the new situation. The structural break, as well as the forecast errors from this model, also permits verifying the public response to pieces of information released regarding the crisis. (Author)

  8. Long-Period Variability in o Ceti

    Science.gov (United States)

    Templeton, Matthew R.; Karovska, Margarita

    2009-02-01

    We carried out a new and sensitive search for long-period variability in the prototype of the Mira class of long-period pulsating variables, o Ceti (Mira A), the closest and brightest Mira variable. We conducted this search using an unbroken light curve from 1902 to the present, assembled from the visual data archives of five major variable star observing organizations from around the world. We applied several time-series analysis techniques to search for two specific kinds of variability: long secondary periods (LSPs) longer than the dominant pulsation period of ~333 days, and long-term period variation in the dominant pulsation period itself. The data quality is sufficient to detect coherent periodic variations with photometric amplitudes of 0.05 mag or less. We do not find evidence for coherent LSPs in o Ceti to a limit of 0.1 mag, where the amplitude limit is set by intrinsic, stochastic, low-frequency variability of approximately 0.1 mag. We marginally detect a slight modulation of the pulsation period similar in timescale to that observed in the Miras with meandering periods, but with a much lower period amplitude of ±2 days. However, we do find clear evidence of a low-frequency power-law component in the Fourier spectrum of o Ceti's long-term light curve. The amplitude of this stochastic variability is approximately 0.1 mag at a period of 1000 days, and it exhibits a turnover for periods longer than this. This spectrum is similar to the red noise spectra observed in red supergiants.

  9. Probe specificity

    International Nuclear Information System (INIS)

    Laget, J.M.

    1986-11-01

    Specificity and complementarity of hadron and electron probes must be systematically developed to answer three questions currently asked in intermediate energy nuclear physics: what is nucleus structure at short distances, what is nature of short range correlations, what is three body force nature [fr

  10. Reactors for nuclear electric propulsion

    Energy Technology Data Exchange (ETDEWEB)

    Buden, D.; Angelo, J.A. Jr.

    1981-01-01

    Propulsion is the key to space exploitation and power is the key to propulsion. This paper examines the role of nuclear fission reactors as the primary power source for high specific impulse electric propulsion systems for space missions of the 1980s and 1990s. Particular mission applications include transfer to and a reusable orbital transfer vehicle from low-Earth orbit to geosynchronous orbit, outer planet exploration and reconnaissance missions, and as a versatile space tug supporting lunar resource development. Nuclear electric propulsion is examined as an indispensable component in space activities of the next two decades.

  11. Reactors for nuclear electric propulsion

    International Nuclear Information System (INIS)

    Buden, D.; Angelo, J.A. Jr.

    1981-01-01

    Propulsion is the key to space exploitation and power is the key to propulsion. This paper examines the role of nuclear fission reactors as the primary power source for high specific impulse electric propulsion systems for space missions of the 1980s and 1990s. Particular mission applications include transfer to and a reusable orbital transfer vehicle from low-Earth orbit to geosynchronous orbit, outer planet exploration and reconnaissance missions, and as a versatile space tug supporting lunar resource development. Nuclear electric propulsion is examined as an indispensable component in space activities of the next two decades

  12. Modeling Residential Electricity Consumption Function in Malaysia: Time Series Approach

    OpenAIRE

    L. L. Ivy-Yap; H. A. Bekhet

    2014-01-01

    As the Malaysian residential electricity consumption continued to increase rapidly, effective energy policies, which address factors affecting residential electricity consumption, is urgently needed. This study attempts to investigate the relationship between residential electricity consumption (EC), real disposable income (Y), price of electricity (Pe) and population (Po) in Malaysia for 1978-2011 period. Unlike previous studies on Malaysia, the current study focuses on the residential secto...

  13. BLUE GOLD: HYDRO-ELECTRIC RENT IN CANADA

    OpenAIRE

    Glenn Jenkins; RICHARD ZUKER

    1984-01-01

    In this study, an attempt is made to develop estimates of the value of economic rent from production of hydro-electricity. These estimates are made for the year 1979, which is the latest period for which a comprehensive set of data was available at the time this work was undertaken. The estimates are developed for the hydro-electricity generated (or used) by electric utilities in four provinces: Quebec (including Churchill Falls), Ontario, Manitoba and British Columbia. These electric systems...

  14. Electricity consumption and economic growth: evidence from Korea

    International Nuclear Information System (INIS)

    Yoo, Seung-Hoon

    2005-01-01

    This paper investigates the short- and long-run causality issues between electricity consumption and economic growth in Korea by using the co-integration and error-correction models. It employs annual data covering the period 1970-2002. The overall results show that there exists bi-directional causality between electricity consumption and economic growth. This means that an increase in electricity consumption directly affects economic growth and that economic growth also stimulates further electricity consumption

  15. Swiss electricity statistics 1996

    International Nuclear Information System (INIS)

    1997-01-01

    This detailed article discusses the following subjects: Survey of electricity supply in Switzerland in 1996; The Swiss electricity balance; Electric power generation; Electric power consumption; Generation, consumption and loads on selected days; Energy trade with other countries; Expansion capacities until 2003; Financial situation and appendix. (orig./RHM) [de

  16. Trojan technical specification verification project

    International Nuclear Information System (INIS)

    Bates, L.; Rickenback, M.

    1991-01-01

    The Trojan Technical Specification Verification (TTSV) project at the Trojan plant of Portland General Electric Company was motivated by the recognition that many numbers in the Trojan technical specifications (TTS) potentially lacked the consideration of instrument- and/or process-related errors. The plant setpoints were known to consider such errors, but many of the values associated with the limiting conditions for operation (LCO) did not. In addition, the existing plant instrument error analyses were based on industry values that do not reflect the Trojan plant-specific experience. The purpose of this project is to ensure that the Trojan plant setpoint and LCO values include plant-specific instrument error

  17. Prognosis following cancer surgery during holiday periods.

    Science.gov (United States)

    Lagergren, Jesper; Mattsson, Fredrik; Lagergren, Pernilla

    2017-11-15

    Surgery is the mainstay curative treatment in most cancer. We aimed to test the new hypothesis that cancer surgery performed during holiday periods is associated with worse long-term prognosis than for non-holiday periods. This nationwide Swedish population-based cohort study included 228,927 patients during 1997-2014 who underwent elective resectional surgery for a cancer where the annual number of resections was over 100. The 16 eligible cancer sites were grouped into 10 cancer groups. The exposure, holiday periods, was classified as wide (14-weeks) or narrow (7-weeks). Surgery conducted inside versus outside holiday periods was compared regarding overall disease-specific (main outcome) and overall all-cause (secondary outcome) mortality. Cox regression provided hazard ratios (HR) with 95% confidence intervals (CI) adjusted for age, sex, comorbidity, hospital volume, calendar period and tumor stage. Surgery conducted during wide and narrow holiday periods were associated with increased HRs of disease-specific mortality for cancer of the breast (HR 1.08, 95% CI 1.03-1.13 and HR 1.06, 95% CI 1.01-1.12) and possibly of cancer of the liver-pancreas-bile ducts (HR 1.09, 95% CI 0.99-1.20 and HR 1.12, 95% CI 0.99-1.26). Sub-groups with cancer of the colon-rectum, head-and-neck, prostate, kidney-urine bladder and thyroid also experienced statistically significantly worse prognosis following surgery conducted during holiday periods. No influence of surgery during holiday was detected for cancer of the esophagus-stomach, lung or ovary-uterus. All-cause HRs were similar to the disease-specific HRs. The prognosis following cancer surgery might not be fully maintained during holiday periods for all cancer sites. © 2017 UICC.

  18. The electricity certificate system, 2008

    Energy Technology Data Exchange (ETDEWEB)

    2008-07-01

    The electricity certificate system is now in its sixth year. Since the start, both the system and the market have developed, and have undergone a number of changes. In January 2007, the Swedish Energy Agency published a report on the system, 'The electricity certificate system, 2006', to provide easily accessible information on the development of the system and to improve general understanding of it. With the passing of another year, it is now time for the third edition, 'The electricity certificate system, 2008', describing the market status of the electricity certificate system, with statistics from 2003 to 2007. This year's special theme chapter describes current support systems for renewable electricity production throughout the EU. The report also contains expanded information and statistics on biofuels, together with a new chapter that describes planned expansion of renewable electricity production up to 2012. The chapter on consumers' contribution to renewable electricity production has also been updated. A new feature this year is provided in the form of a number of tables at the end of the report, complementing the text. Through annual publication of the report, we hope to create a means of continuously developing the statistical material and analyses, in order to assist those involved in the market, and all other interested persons, to follow achievement of the objectives set out in the Government's Bill No. 205/06:154, 'Renewable electricity with green certificates'. We welcome views on the content and presentation of the report in order further to improve it. The target for the certificate system is to increase, by 2016, the annual production of electricity from renewable sources by 17 TWh relative to its production in 2002. So far, the actual production of renewable electricity is less than the indicative stage target for 2007. Nevertheless, progress is regarded as good, as there are many planned projects

  19. The influence of the reactive energy in the electric power sector planning and the need of consolidation of the hourly period for evaluation of the power factor of the loads; A influencia da energia eletrica reativa no planejamento do setor eletrico e a necessidade de consolidacao do periodo horario para avaliacao do fator de potencia das cargas

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Moacyr Trindade de Oliveira

    1993-07-01

    Among expectations of optimization of electric power systems and the national electric rating laws, there is the important factors of consumption and transmission of reactive energy which concerns the objectives of electric sector. Related to it, the DNAEE, ELETROBRAS and the concessionaires have been developing studies in order to optimize the electric system performance, and consequently the investments of concessionaires and consumers, reducing costs imposed to society due to the form of consumption and/or compensation of reactive loads. This work shows the evolution and consolidation of tariff studies and electric performance of the system, indicating the ways which attend the expectations os all segments of the society through a small adaptation of present regulations an rules related to reactive energy, making possible the system growing in supply by the minimum cost. The main objective of this work is to reinforce the real necessity of to remain intact all the new regulation of power factor, that has been consolidated by the DNAEE's document number 085/92 and your revaluation document number 613/93, including the interval of hourly integration for reactive energy at the determinate date and show the damages for the society caused by the postponement of this condition, that has been considerate in the document number 613/93, from April 1994 until April 1996, however keeping in 1994 the introduction of the new power factor reference of 0.92. (author)

  20. The influence of the reactive energy in the electric power sector planning and the need of consolidation of the hourly period for evaluation of the power factor of the loads; A influencia da energia eletrica reativa no planejamento do setor eletrico e a necessidade de consolidacao do periodo horario para avaliacao do fator de potencia das cargas

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Moacyr Trindade de Oliveira

    1993-07-01

    Among expectations of optimization of electric power systems and the national electric rating laws, there is the important factors of consumption and transmission of reactive energy which concerns the objectives of electric sector. Related to it, the DNAEE, ELETROBRAS and the concessionaires have been developing studies in order to optimize the electric system performance, and consequently the investments of concessionaires and consumers, reducing costs imposed to society due to the form of consumption and/or compensation of reactive loads. This work shows the evolution and consolidation of tariff studies and electric performance of the system, indicating the ways which attend the expectations os all segments of the society through a small adaptation of present regulations an rules related to reactive energy, making possible the system growing in supply by the minimum cost. The main objective of this work is to reinforce the real necessity of to remain intact all the new regulation of power factor, that has been consolidated by the DNAEE's document number 085/92 and your revaluation document number 613/93, including the interval of hourly integration for reactive energy at the determinate date and show the damages for the society caused by the postponement of this condition, that has been considerate in the document number 613/93, from April 1994 until April 1996, however keeping in 1994 the introduction of the new power factor reference of 0.92. (author)