WorldWideScience

Sample records for perfused rabbit lung

  1. Effect of Garlic on Perfusion Scintigraphy of Rabbit's Lungs ...

    African Journals Online (AJOL)

    Purpose: To study of the effect of garlic on rabbit's lungs, with the aid of perfusion scintigraphy, after experimentally-induced pulmonary embolism. Methods: Twelve adult rabbits were anesthetized. Prepared macroaggregated albumin- technetium 99m (99mTc-MAA) radiopharmaceutical was injected into the ear vein at a ...

  2. Propofol attenuates oxidant-induced acute lung injury in an isolated perfused rabbit-lung model.

    Science.gov (United States)

    Yumoto, Masato; Nishida, Osamu; Nakamura, Fujio; Katsuya, Hirotada

    2005-01-01

    Reactive oxygen species have been strongly implicated in the pathogenesis of acute lung injury (ALI). Some animal studies suggest that free radical scavengers inhibit the onset of oxidant-induced ALI. Propofol (2,6-diisopropylphenol) is chemically similar to phenol-based free radical scavengers such as the endogenous antioxidant vitamin E. Both in vivo and in vitro studies have suggested that propofol has antioxidant potential. We hypothesized that propofol may attenuate ALI by acting as a free-radical scavenger. We investigated the effects of propofol on oxidant-induced ALI induced by purine and xanthine oxidase (XO), in isolated perfused rabbit lung, in two series of experiments. In series 1, we examined the relationship between the severity of ALI and the presence of hydrogen peroxide (H2O2). In series 2, we evaluated the effects of propofol on attenuating ALI and the dose dependence of these effects. The lungs were perfused for 90 min, and we evaluated the effects on the severity of ALI by monitoring the pulmonary capillary filtration coefficient (Kfc), pulmonary arterial pressure (Ppa), and the pulmonary capillary hydrostatic pressure (Ppc). In series 1, treatment with catalase (an H2O2 scavenger) prior to the addition of purine and XO resulted in complete prevention of ALI, suggesting that H2O2 may be involved closely in the pathogenesis of ALI. In series 2, pretreatment with propofol at concentrations in excess of 0.5 mM significantly inhibited the increases in the Kfc values, and that in excess of 0.75 mM significantly inhibited the increase in the Ppa values. Propofol attenuates oxidant-induced ALI in an isolated perfused rabbit lung model, probably due to its antioxidant action.

  3. Effect of Garlic on Perfusion Scintigraphy of Rabbit's Lungs ...

    African Journals Online (AJOL)

    Animals. A total number of 12 mixed bred rabbits weighing. 3.5 ± 0.5 kg were selected. Then, the necessary blood and parasite analysis as well as clinical ..... 8. Flecknell PA, Ed. BSAVA manual of rabbit medicine and surgery. London: British Small Animal Veterinary. Association; 2000; pp 30-31, 106. 9. Ji Y, Gao H, Zhang ...

  4. The uptake and metabolism of cystamine and taurine by isolated, ventilated and perfused rat and rabbit lungs

    International Nuclear Information System (INIS)

    Sharma, R.; Kodavanti, U.P.; Smith, L.L.; Mehendale, H.M.

    1991-01-01

    Cystamine has been reported to be taken up by the lung slices and metabolized to taurine via hypotaurine through enzymatic processes. The objective of these studies was to determine whether intact isolated, ventilated and perfused rat and rabbit lungs also posses similar characteristics. The lungs were isolated from male New Zealand white rabbits and S-D rats and perfused with 20 μM [ 14 C] cystamine (Sp. Act., 16.4 mCi/mmol) for 60 min and 30 min, respectively. Cystamine and its metabolites in lung as well as in perfusate were separated by TLC and quantitated using scintillation spectrometry. Similar experiments were also conducted with 20 μM taurine to investigate its fate in perfused lungs. Significant pulmonary uptake of cystamine and taurine occurred during perfusion. Cystamine was metabolized to [ 14 C] hypotaurine and [ 14 C] taurine. No further metabolism of taurine was evident in rat or rabbit lungs. Inclusion of 1 nM GSH did not significantly alter the ability of lungs to sequester cystamine, but the metabolism of hypotaurine to taurine was decreased. It was evident that cystamine was metabolized to taurine by perfused lungs in the same way as in lung slices

  5. Removal of atrial natriuretic factor by perfused rabbit lungs in situ

    International Nuclear Information System (INIS)

    Turrin, M.; Maack, T.; Gillis, C.N.

    1986-01-01

    Because atrial natriuretic factor (ANF) can be released from the right atrium into pulmonary blood, the authors studied the possibility of uptake of the peptide by rabbit lung, perfused in situ, at 20 ml/min with Krebs-albumin medium. Single pass removal (multiple indicator dilution with 14 C-dextran as reference) of trace amounts (40 pmoles) of 125 I-ANF was 66 +/- 4% (n=12). This was reduced to 8 +/- 4% by co-injection of 10 μM ANF but was unchanged by co-injection of CPAP (340 nM), an inhibitor of angiotensin-converting enzyme (ACE). When 125 I-ANF was re-circulated through lung, uptake reached maximum at 14 min (64 +/- 5%; n=7). Efflux of 125 I-ANF from preloaded lungs was monoexponential with t/sub 1/2/ = 17.7 min. Recovery of 125 I-ANF uptake after block by unlabelled ANF was studied. For this purpose, lungs were loaded with 0.1 μM unlabelled ANF by recirculating for 20 minutes, after which medium was changed to Krebs-albumin and removal of bolus injections of 125 I-ANF was measured every 5 min. Removal of 125 I-ANF, initially 0%, returned to control levels after 20 min. Thus, 125 I-ANF is removed from the pulmonary circulation by a saturable and reversible process which probably does not involve binding to the ACE present on endothelial cells

  6. Removal of atrial natriuretic factor by perfused rabbit lungs in situ

    Energy Technology Data Exchange (ETDEWEB)

    Turrin, M.; Maack, T.; Gillis, C.N.

    1986-03-05

    Because atrial natriuretic factor (ANF) can be released from the right atrium into pulmonary blood, the authors studied the possibility of uptake of the peptide by rabbit lung, perfused in situ, at 20 ml/min with Krebs-albumin medium. Single pass removal (multiple indicator dilution with /sup 14/C-dextran as reference) of trace amounts (40 pmoles) of /sup 125/I-ANF was 66 +/- 4% (n=12). This was reduced to 8 +/- 4% by co-injection of 10 ..mu..M ANF but was unchanged by co-injection of CPAP (340 nM), an inhibitor of angiotensin-converting enzyme (ACE). When /sup 125/I-ANF was re-circulated through lung, uptake reached maximum at 14 min (64 +/- 5%; n=7). Efflux of /sup 125/I-ANF from preloaded lungs was monoexponential with t/sub 1/2/ = 17.7 min. Recovery of /sup 125/I-ANF uptake after block by unlabelled ANF was studied. For this purpose, lungs were loaded with 0.1 ..mu..M unlabelled ANF by recirculating for 20 minutes, after which medium was changed to Krebs-albumin and removal of bolus injections of /sup 125/I-ANF was measured every 5 min. Removal of /sup 125/I-ANF, initially 0%, returned to control levels after 20 min. Thus, /sup 125/I-ANF is removed from the pulmonary circulation by a saturable and reversible process which probably does not involve binding to the ACE present on endothelial cells.

  7. Activation of rho is involved in the mechanism of hydrogen-peroxide-induced lung edema in isolated perfused rabbit lung.

    Science.gov (United States)

    Chiba, Y; Ishii, Y; Kitamura, S; Sugiyama, Y

    2001-09-01

    Acute lung injury is attributed primarily to increased vascular permeability caused by reactive oxygen species derived from neutrophils, such as hydrogen peroxide (H2O2). Increased permeability is accompanied by the contraction and cytoskeleton reorganization of endothelial cells, resulting in intercellular gap formation. The Rho family of Ras-like GTPases is implicated in the regulation of the cytoskeleton and cell contraction. We examined the role of Rho in H2O2-induced pulmonary edema with the use of isolated perfused rabbit lungs. To our knowledge, this is the first study to examine the role of Rho in increased vascular permeability induced by H2O2 in perfused lungs. Vascular permeability was evaluated on the basis of the capillary filtration coefficient (Kfc, ml/min/cm H2O/100 g). We found that H2O2 (300 microM) increased lung weight, Kfc, and pulmonary capillary pressure. These effects of H2O2 were abolished by treatment with Y-27632 (50 microM), an inhibitor of the Rho effector p160 ROCK. In contrast, the muscular relaxant papaverine inhibited the H2O2-induced rise in pulmonary capillary pressure, but did not suppress the increases in lung weight and Kfc. These findings indicate that H2O2 causes pulmonary edema by elevating hydrostatic pressure and increasing vascular permeability. Y-27632 inhibited the formation of pulmonary edema by blocking both of these H2O2-induced effects. Our results suggest that Rho-related pathways have a part in the mechanism of H2O2-induced pulmonary edema. Copyright 2001 Academic Press.

  8. Lung perfusion scintigraphy by SPECT

    International Nuclear Information System (INIS)

    Hirayama, Takanobu

    1990-01-01

    The initial study reports the characteristic performance using lung segmental phantom filled in Tc-99m pertechnetate. To evaluate the segmental defect in lung perfusion scintigraphy, we applied Bull's-eye analysis in addition to planar image set. Bull's-eye analysis especially facilitated the interpretation in both middle and lower lobes. Subsequently, to evolute the clinical application of Bull's-eye analysis, pulmonary scintigraphy was performed on 10 normal subjects and 60 patients with several pulmonary diseases. Of interest, Bull's-eye analysis, however, encouraged the interpretation in both lower lobes. To calculate the extention and severity of perfusion defect, the present study describes Bull's-eye analysis. Quantitative scoring showed higher in patients with lung cancer than those with pulmonary tuberculosis. The present study focus that Bull's-eye analysis can be useful for evaluating perfusion in patients with a couple of pulmonary diseases. (author)

  9. Normal anatomy of lung perfusion SPECT scintigraphy

    International Nuclear Information System (INIS)

    Moskowitz, G.W.; Levy, L.M.

    1987-01-01

    Ten patients studies for possible pulmonary embolic disease had normal lung perfusion planar and SPECT scintigraphy. A computer program was developed to superimpose the CT scans on corresponding SPECT images. Superimposition of CT scans on corresponding SPECT transaxial cross-sectional images, when available, provides the needed definition and relationships of adjacent organs. SPECT transaxial sections provide clear anatomic definition of perfusion defects without foreground and background lung tissue superimposed. The location, shape, and size of the perfusion defects can be readily assessed by SPECT. An algorithm was developed for the differentiation of abnormal pulmonary perfusion patterns from normal structures on variation

  10. Quantitative lung perfusion evaluation using Fourier decomposition perfusion MRI.

    Science.gov (United States)

    Kjørstad, Åsmund; Corteville, Dominique M R; Fischer, Andre; Henzler, Thomas; Schmid-Bindert, Gerald; Zöllner, Frank G; Schad, Lothar R

    2014-08-01

    To quantitatively evaluate lung perfusion using Fourier decomposition perfusion MRI. The Fourier decomposition (FD) method is a noninvasive method for assessing ventilation- and perfusion-related information in the lungs, where the perfusion maps in particular have shown promise for clinical use. However, the perfusion maps are nonquantitative and dimensionless, making follow-ups and direct comparisons between patients difficult. We present an approach to obtain physically meaningful and quantifiable perfusion maps using the FD method. The standard FD perfusion images are quantified by comparing the partially blood-filled pixels in the lung parenchyma with the fully blood-filled pixels in the aorta. The percentage of blood in a pixel is then combined with the temporal information, yielding quantitative blood flow values. The values of 10 healthy volunteers are compared with SEEPAGE measurements which have shown high consistency with dynamic contrast enhanced-MRI. All pulmonary blood flow (PBF) values are within the expected range. The two methods are in good agreement (mean difference = 0.2 mL/min/100 mL, mean absolute difference = 11 mL/min/100 mL, mean PBF-FD = 150 mL/min/100 mL, mean PBF-SEEPAGE = 151 mL/min/100 mL). The Bland-Altman plot shows a good spread of values, indicating no systematic bias between the methods. Quantitative lung perfusion can be obtained using the Fourier Decomposition method combined with a small amount of postprocessing. Copyright © 2013 Wiley Periodicals, Inc.

  11. Study of lung perfusion in colagenosis

    International Nuclear Information System (INIS)

    Macedo de Carvalho, A.C.; Calegaro, J.U.M.

    1982-01-01

    The lung involvement in the various types of colagenosis has been widely described in the literature. However, the study of lung perfusion utilizing radionuclides has been only mentioned in a few papers. With the intention of ascertaining the importance of the lung perfusion scanning in colagenosis, ten cases were studied, seven of which were females and three males, with the following pathologies: 4 rheumatoid arthritis, 4 systemic lupus eritematosous, 1 scleroderma and 1 scleroderma plus dermatomyositis. The ages of the patients varied from 20 to 73 years, and the duration of the disease from 1 month to 39 years. The lung scanning showed perfusion defects in 100% of the cases, not related with the type of colagenosis, duration of the disease, sex or age. On the other hand, the X rays study showed alterations in only 2 patients (20% of the cases). The ventilatory and respiratory functions were tested on 7 patients showing alteration (mixed pattern with predominance of the restrictive factor) in only one (14.3%), while the other patients were normal (85.7%). The importance of the lung perfusion scanning study in all patients with collagen vascular diseases is emphasized. (author) [es

  12. Study of lung perfusion in colagenosis

    Energy Technology Data Exchange (ETDEWEB)

    Macedo de Carvalho, A C; Calegaro, J U.M. [Fundacao Hospitalar do Distrito Federal, Distrito Federal (Brazil). Unidade de Medicina Nuclear

    1982-07-01

    The lung involvement in the various types of colagenosis has been widely described in the literature. However, the study of lung perfusion utilizing radionuclides has been only mentioned in a few papers. With the intention of ascertaining the importance of the lung perfusion scanning in colagenosis, ten cases were studied, seven of which were females and three males, with the following pathologies: 4 rheumatoid arthritis, 4 systemic lupus eritematosous, 1 scleroderma and 1 scleroderma plus dermatomyositis. The ages of the patients varied from 20 to 73 years, and the duration of the disease from 1 month to 39 years. The lung scanning showed perfusion defects in 100% of the cases, not related with the type of colagenosis, duration of the disease, sex or age. On the other hand, the X rays study showed alterations in only 2 patients (20% of the cases). The ventilatory and respiratory functions were tested on 7 patients showing alteration (mixed pattern with predominance of the restrictive factor) in only one (14.3%), while the other patients were normal (85.7%). The importance of the lung perfusion scanning study in all patients with collagen vascular diseases is emphasized.

  13. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Y.; Hayashida, K.; Uehara, T.; Shimonagata, T.; Nishimura, T.; Osaka Univ., Suita

    1993-01-01

    15 cases of primary pulmonary hypertension were classified into two groups by patterns of perfusion lung scintigraphy. Perfusion scintigrams showed multiple, small, ill-defined defects (mottled + ve) pattern in eight cases, and the remaining seven cases had a normal (mottled - ve) pattern. The mean pulmonary arterial pressure in patients with a mottled pattern (54 ± 10 mmHg) was higher than in those with a normal pattern (42 ± 9 mmHg, p < 0.05). There were no significant differences between the two groups in right ventricular ejection fraction, partial pressures of oxygen in the arterial blood or alveolo-arterial oxygen difference. All the patients with a mottled pattern died within 2 years following the lung scintigraphy. There was a significant difference in the survival curves between the two groups. (author)

  14. Perfusion lung scintigraphy in primary pulmonary hypertension

    International Nuclear Information System (INIS)

    Ogawa, Yoji; Nishimura, Tsunehiko; Kumita, Shin-ichirou; Hayashida, Kohei; Uehara, Toshiisa; Shimonagata, Tsuyoshi; Ohno, Akira

    1991-01-01

    Fifteen cases with primary pulmonary hypertension (PPH) were classified into two groups by using the perfusion lung scan pattern. Eight cases had multiple, small, ill-defined defects (mottled pattern), and remaining seven cases had no mottled pattern. These two groups were compared with mean pulmonary arterial pressure (mean PAP), right ventricular ejection fraction (RVEF), blood gas at room air (PaO 2 ), and alveolar-arterial O 2 difference (A-aDo 2 ). The cases with mottled pattern showed a significant increase in mean PAP. There were no significant differences in RVEF, PaO 2 , and A-aDo 2 , between the groups. The survival rate of the patients with mottled pattern was significantly lower than that without mottled pattern (p<0.05). We concluded that perfusion lung scan is very useful for evaluation of the prognosis in primary pulmonary hypertension. (author)

  15. Relative permeability of the endothelium and epithelium of rabbit lungs

    International Nuclear Information System (INIS)

    Effros, R.M.; Mason, G.R.; Silverman, P.; Hukkanen, J.

    1986-01-01

    Electron micrographic studies of lungs suggest that the epithelial cells are more tightly joined than the underlying endothelium, and macromolecules penetrate the endothelium more readily than the epithelium. Comparisons of epithelial and endothelial permeability to small molecules have been based upon the relative rates at which solutes traverse the alveolar-capillary barrier in fluid filled lungs and those at which they equilibrate across the capillaries in air-filled lungs. Because the former process is much slower than the latter, it has been concluded that the epithelium is less permeable to small solutes than the endothelium. However this difference may be related to inadequate access of solutes to airway surfaces. In this study, solute losses from the vascular space were compared to those from the airspace in perfused, fluid-filled rabbit lungs. 36 Cl - and 125 I - were lost from air-spaces almost twice as rapidly as 22 Na + . In contrast, the endothelium is equally permeable to 22 Na + and these anions. Loss of 3 H-mannitol from the perfusate resembled that of 22 Na + for about 30 minutes, after which diffusion of 3 H-mannitol into the tissue nearly ceased. These observations suggest that the epithelium is more permselective than the endothelium. By resisting solute and water transport, the epithelium tends to prevent alveolar flooding and confines edema to the interstitium, where it is less likely to interfere with gas exchange

  16. Lung perfusion scintigraphy in congenital heart disease

    International Nuclear Information System (INIS)

    Sugimura, Hiroshi; Nagamachi, Shigeki; Hoshi, Hiroaki; Jinnouchi, Seishi; Oonishi, Takashi; Futami, Shigemi; Watanabe, Katsushi

    1990-01-01

    Lung perfusion scintigrams were reviewed retrospectively in 28 patients with congenital heart disease, whose ages ranged from the first year to 16 years with an average age of 5 years and 6 months. Seventy four MBq (2 mCi), 111 MBq (2 mCi), and 185 MBq (5 mCi) of Tc-99m macroaggregated albumin were iv injected in the age groups of 0-3, 4-11, and more than 11 years, respectively. Five minutes later, images were obtained in six projections. Abnormal findings on lung perfusion scintigrams were observed in 13 patients (46%). Of these patients, 8 (29%) had a partially decreased blood flow and 5 (17%) had a decreased blood flow in the unilateral lung. No significant difference in the occurrence of abnormal findings was observed among the age groups, although they tended to occur in younger patients. Sex, underlying conditions, and hemodynamics were also independent of scintigraphically abnormal findings. Even when classifying the patients as having either cyanotic or non-cyanotic heart disease, no significant difference in hemodynamics was observed between the group of abnormal findings and the group of normal findings. Pulmonary arteriography available in all patients failed to reveal abnormal findings, with the exception of pulmonary artery stenosis in 2 patients that corresponded to a decreased blood flow in the unilateral lung. Pulmonary artery stenosis seemed to be responsible for abnormal pulmonary blood flow, although other causes remained uncertain. (N.K.)

  17. Emergency perfusion lung scan of pulmonary embolism

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Kabuto, Hiroko; Rikimaru, Shigeho

    1984-01-01

    Pulmonary embolism (PE) has been reported to be quite rare in Japan, and there have been few clinical studies on the nuclear diagnosis of PE with the exception of several case reports. However, we have experienced 12 acute PE, and 2 chronic PE in 5 years 2 months. In 33 emergency cases who were highly suspected to have PE, we could diagnose 12 cases of PE, and 19 cases of non-PE. However, the remaining 2 cases were equivocal because of underlying chronic lung disease. Using Kr-81m ventilation lung scan, V/Q mismatch was found in all of 10 cases. Usefulness of emergency perfusion lung scan in Japan should be stressed. (author)

  18. Xeno- and auto-perfusion of rabbit kidney. Machine perfusion with blood at 37 degrees C

    DEFF Research Database (Denmark)

    Jørgensen, K A; Kemp, E; Barfort, P

    1985-01-01

    damage, exudation, and IgG deposits along the basement membrane of the glomerular capillaries were the discriminative features of the xenoperfusion. In these experiments, we were unable to demonstrate any major role of platelets in the process leading to decreased blood flow.......Five rabbit kidneys were perfused with human blood and another five with their own blood in a re-circulating oxygenated system at 37 degrees C. The flow decreased to 2 ml/min. within 30 min. in all xenoperfusions, while none of the autoperfused had decreased to this level by 60 min. Endothelial...

  19. Synergism between endotoxin priming and exotoxin challenge in provoking severe vascular leakage in rabbit lungs.

    Science.gov (United States)

    Schütte, H; Rosseau, S; Czymek, R; Ermert, L; Walmrath, D; Krämer, H J; Seeger, W; Grimminger, F

    1997-09-01

    Lipopolysaccharides (LPS) of gram-negative bacteria prime rabbit lungs for enhanced thromboxane-mediated vasoconstriction upon subsequent challenge with the exotoxin Escherichia coli hemolysin (HlyA) (Walmrath et al. J. Exp. Med. 1994;180:1437-1443). We investigated the impact of endotoxin priming and subsequent HlyA challenge on lung vascular permeability while maintaining constancy of capillary pressure. Rabbit lungs were perfused in a pressure-controlled mode in the presence of the thromboxane receptor antagonist BM 13.505, with continuous monitoring of flow. Perfusion for 180 min with 10 ng/ml LPS did not provoke vasoconstriction or alteration of capillary filtration coefficient (Kfc) values. HlyA (0.021 hemolytic units/ml) induced thromboxane release and a transient decrease in perfusion flow in the absence of significant changes in Kfc. Similar results were obtained when LPS and HlyA were coapplied simultaneously. However, when the HlyA challenge was undertaken after 180 min of LPS priming, a manifold increase in Kfc values was noted, with concomitant severe lung edema formation, although capillary pressure remained unchanged. Thus, endotoxin primes the lung vasculature to respond with a severe increase in vascular permeability to a subsequent low-dose application of HlyA. Such synergism between endotoxin priming and exotoxin challenge in provoking lung vascular leakage may contribute to the pathogenesis of respiratory failure in sepsis and severe lung infection.

  20. Perfusion lung scanning: differentiation of primary from thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Lisbona, R.; Kreisman, H.; Novales-Diaz, J.; Derbekyan, V.

    1985-01-01

    Of eight patients with pulmonary arterial hypertension, final diagnosis established by autopsy or angiography, four had primary hypertension and four hypertension from thromboembolism. The perfusion lung scan was distinctly different in the two groups. The lung scan in primary pulmonary hypertension was associated with nonsegmental, patchy defects of perfusion, while in thromboembolic hypertensives it was characterized by segmental and/or lobar defects of perfusion with or without subsegmental defects. The perfusion lung scan is a valuable, noninvasive study in the evaluation of the patient with pulmonary hypertension of undetermined cause and in the exclusion of occult large-vessel pulmonary thromboembolism

  1. Polarographic measurement of ascorbate washout in isolated perfused rabbit hearts

    International Nuclear Information System (INIS)

    Arts, T.; Kuikka, J.T.; Reneman, R.S.; Bassingthwaighte, J.B.

    1985-01-01

    To study the myocardial washout of ascorbate, the applicability of polarographic detection of ascorbate ions by a platinum electrode (sensitive area 0.03 mm2) was investigated, in both a calibration setup (sampling flow along the electrode: 100 microliter X s-1) and isolated, retrogradely perfused rabbit hearts. In the calibration setup at pH 7.4, the sensitivity of the electrode was 70 microA/mol. This sensitivity increased moderately with increasing pH (13%/unit pH) and increasing sampling flow rate (14% at an increase from 100 to 150 microliter X s-1). In the isolated hearts, ascorbate infused into the aorta was detected in a right ventricular drain by the electrode as well as by the use of 14 C-labeled ascorbate. Both recorded time courses were similar except for a scaling factor dependent on flow velocity. During continuous infusion the arteriovenous difference of ascorbate was 2 +/- 2% (SD), indicating a relatively low consumption of ascorbate by the isolated heart. The authors conclude that polarographic measurement of ascorbate in the coronary effluent of an isolated rabbit heart can be performed on-line and relatively easily

  2. Reversible ventilation and perfusion abnormalities in unilateral obstructed lung

    International Nuclear Information System (INIS)

    Ward, H.E.; Jones, R.L.; King, E.G.; Sproule, B.J.; Fortune, R.L.

    1982-01-01

    An intraluminal carcinoid tumor obstructing the left mainstem bronchus produced hypoxemia through alteration in ventilation/perfusion matching. Studies of regional lung function using 133-xenon (/sup 133/Xe) and a multiprobe computerized instrumentation system documented a reduction of perfusion to 22 percent and ventilation to 6 percent of the total. There was negligible washout of intravenously injected /sup 133/Xe from the left lung consistent with air trapping. Four days after left mainstem bronchial sleeve resection, perfusion, ventilation and washout of injected xenon had significantly improved and by four months postresection, all measurements were virtually normal, although complete restoration of perfusion in relation to ventilation was delayed. Regional lung function studied with a multiprobe system in this patient provided a clinical model for the study of ventilation and perfusion inter-relationships in large airway obstruction and demonstrated that a prolonged time may be required for return of perfusion to normal

  3. Tissue to plasma capillary permeability of 131I-albumin in the perfused rabbit ear

    DEFF Research Database (Denmark)

    Bent-Hansen, L; Svendsen, Jesper Hastrup

    1991-01-01

    The tissue to plasma transfer of 131I-albumin was recorded in perfused rabbit ears (n = 6) following equilibration for 24 hr. 125I-fibrinogen served as the plasma marker, and was introduced intravenously 15 min before clamping. The ears were rollerpump perfused with isotonic diluted plasma...

  4. Improved visualization of delayed perfusion in lung MRI

    International Nuclear Information System (INIS)

    Risse, Frank; Eichinger, Monika; Kauczor, Hans-Ulrich; Semmler, Wolfhard; Puderbach, Michael

    2011-01-01

    Introduction: The investigation of pulmonary perfusion by three-dimensional (3D) dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) was proposed recently. Subtraction images are generated for clinical evaluation, but temporal information is lost and perfusion defects might therefore be masked in this process. The aim of this study is to demonstrate a simple analysis strategy and classification for 3D-DCE-MRI perfusion datasets in the lung without omitting the temporal information. Materials and methods: Pulmonary perfusion measurements were performed in patients with different lung diseases using a 1.5 T MR-scanner with a time-resolved 3D-GRE pulse sequence. 25 3D-volumes were acquired after iv-injection of 0.1 mmol/kg KG Gadolinium-DTPA. Three parameters were determined for each pixel: (1) peak enhancement S n,max normalized to the arterial input function to detect regions of reduced perfusion; (2) time between arterial peak enhancement in the large pulmonary artery and tissue peak enhancement τ to visualize regions with delayed bolus onset; and (3) ratio R = S n,max /τ was calculated to visualize impaired perfusion, irrespectively of whether related to reduced or delayed perfusion. Results: A manual selection of peak perfusion images is not required. Five different types of perfusion can be found: (1) normal perfusion; (2) delayed non-reduced perfusion; (3) reduced non-delayed perfusion; (4) reduced and delayed perfusion; and (5) no perfusion. Types II and IV could not be seen in subtraction images since the temporal information is necessary for this purpose. Conclusions: The analysis strategy in this study allows for a simple and observer-independent visualization and classification of impaired perfusion in dynamic contrast-enhanced pulmonary perfusion MRI by using the temporal information of the datasets.

  5. Magnetic Resonance Imaging of Ventilation and Perfusion in the Lung

    Science.gov (United States)

    Prisk, Gordon Kim (Inventor); Hopkins, Susan Roberta (Inventor); Buxton, Richard Bruce (Inventor); Pereira De Sa, Rui Carlos (Inventor); Theilmann, Rebecca Jean (Inventor); Cronin, Matthew Vincent (Inventor)

    2017-01-01

    Methods, devices, and systems are disclosed for implementing a fully quantitative non-injectable contrast proton MRI technique to measure spatial ventilation-perfusion (VA/Q) matching and spatial distribution of ventilation and perfusion. In one aspect, a method using MRI to characterize ventilation and perfusion in a lung includes acquiring an MR image of the lung having MR data in a voxel and obtaining a breathing frequency parameter, determining a water density value, a specific ventilation value, and a perfusion value in at least one voxel of the MR image based on the MR data and using the water density value to determine an air content value, and determining a ventilation-perfusion ratio value that is the product of the specific ventilation value, the air content value, the inverse of the perfusion value, and the breathing frequency.

  6. Active Oxygen Metabolites and Thromboxane in Phorbol Myristate Acetate Toxicity to the Isolated, Perfused Rat Lung.

    Science.gov (United States)

    Carpenter, Laurie Jean

    When administered intravenously or intratracheally to rats, rabbits and sheep, phorbol myristate acetate (PMA) produces changes in lung morphology and function are similar to those seen in humans with the adult respiratory distress syndrome (ARDS). Therefore, it is thought that information about the mechanism of ARDS development can be gained from experiments using PMA-treated animals. Currently, the mechanisms by which PMA causes pneumotoxicity are unknown. Results from other studies in rabbits and in isolated, perfused rabbit lungs suggest that PMA-induced lung injury is mediated by active oxygen species from neutrophils (PMN), whereas studies in sheep and rats suggest that PMN are not required for the toxic response. The role of PMN, active oxygen metabolites and thromboxane (TxA_2) in PMA-induced injury to isolated, perfused rat lungs (IPLs) was examined in this thesis. To determine whether PMN were required for PMA to produce toxicity to the IPL, lungs were perfused for 30 min with buffer containing various concentrations of PMA (in the presence or absence of PMN). When concentrations >=q57 ng/ml were added to medium devoid of added PMN, perfusion pressure and lung weight increased. When a concentration of PMA (14-28 ng/ml) that did not by itself cause lungs to accumulate fluid was added to the perfusion medium containing PMN (1 x 10 ^8), perfusion pressure increased, and lungs accumulated fluid. These results indicate that high concentrations of PMA produce lung injury which is independent of PMN, whereas injury induced by lower concentrations is PMN-dependent. To examine whether active oxygen species were involved in mediating lung injury induced by PMA and PMN, lungs were coperfused with the oxygen radical scavengers SOD and/or catalase. Coperfusion with either or both of these enzymes totally protected lungs against injury caused by PMN and PMA. These results suggest that active oxygen species (the hydroxyl radical in particular), mediate lung injury in

  7. Serial perfusion in native lungs in patients with idiopathic pulmonary fibrosis and other interstitial lung diseases after single lung transplantation.

    Science.gov (United States)

    Sokai, Akihiko; Handa, Tomohiro; Chen, Fengshi; Tanizawa, Kiminobu; Aoyama, Akihiro; Kubo, Takeshi; Ikezoe, Kohei; Nakatsuka, Yoshinari; Oguma, Tsuyoshi; Hirai, Toyohiro; Nagai, Sonoko; Chin, Kazuo; Date, Hiroshi; Mishima, Michiaki

    2016-04-01

    Lung perfusions after single lung transplantation (SLT) have not been fully clarified in patients with interstitial lung disease (ILD). The present study aimed to investigate temporal changes in native lung perfusion and their associated clinical factors in patients with ILD who have undergone SLT. Eleven patients were enrolled. Perfusion scintigraphy was serially performed up to 12 months after SLT. Correlations between the post-operative perfusion ratio in the native lung and clinical parameters, including pre-operative perfusion ratio and computed tomography (CT) volumetric parameters, were evaluated. On average, the perfusion ratio of the native lung was maintained at approximately 30% until 12 months after SLT. However, the ratio declined more significantly in idiopathic pulmonary fibrosis (IPF) than in other ILDs (p = 0.014). The perfusion ratio before SLT was significantly correlated with that at three months after SLT (ρ = 0.64, p = 0.048). The temporal change of the perfusion ratio in the native lung did not correlate with those of the CT parameters. The pre-operative perfusion ratio may predict the post-operative perfusion ratio of the native lung shortly after SLT in ILD. Perfusion of the native lung may decline faster in IPF compared with other ILDs. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Ventilation-perfusion lung imaging in diaphragmatic paralysis

    International Nuclear Information System (INIS)

    Chopra, S.K.; Taplin, G.V.

    1977-01-01

    Clinical, radiological, physiological, and lung imaging findings from a patient with paralysis of the diaphragm are described. Dyspnea, hypoxemia and hypercapnia increased when the patient changed from the upright to the supine positions. Ventilation (V) and perfusion (P) images of the right lung appeared to be relatively normal and remained nearly the same in the upright and supine positions. In contrast, V/P images of the left lung were smaller than those of the right lung in the upright position and decreased further in the supine position. In addition, the size of the ventilation image was much smaller than that of the perfusion

  9. Hot spots on Tc-99m MAA perfusion lung scan

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Sohn, Myung Hee

    2001-01-01

    A 61 year-old woman underwent perfusion and inhalation lung scan for the evaluation of pulmonary thromboembolism. Tc-99m MAA perfusion lung scan showed multiple round hot spots in both lung fields. Tc-99m DTPA aerosol inhalation lung scan and chest radiography taken at the same time showed normal findings. A repeated perfusion lung scan taken 24 hours later demonstrated no abnormalities. Hot spots on perfusion lung scan can be caused by microsphere clumping due to faulty injection technique by radioactive embolization from upper extremity thrombophlebitis after injection. Focal hot spots can signify zones of atelectasis, where the hot spots probably represent a failure of hypoxic vasoconstriction. Artifactual hot spots due to microsphere clumping usually appear to be round and in peripheral location, and the lesions due to a loss of hypoxic vasoconstriction usually appear to be hot uptakes having linear borders. Although these artifactual hot spots have been well-known, we rarely encounter them. This report presents a case with artifactual hot spots due to microsphere clumping on Tc-99m MAA perfusion lung scan

  10. The relationship between ventilatory lung motion and pulmonary perfusion shown by ventilatory lung motion imaging

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Nakatsuka, Tatsuya; Yoshimura, Kazuhiko; Hirose, Yoshiki; Hirayama, Jiro; Kobayashi, Toshio; Handa, Kenjiro

    1991-01-01

    Using ventilatory lung motion imaging, which was obtained from two perfusion lung scintigrams with 99m Tc-macroaggregated albumin taken in maximal inspiration and maximal expiration, the lung motion (E-I/I) of the each unilateral lung was studied in various cardiopulmonary diseases. The sum of (E-I)/I(+) of the unilateral lung was decreased in the diseased lung for localized pleuropulmonary diseases, including primary lung cancer and pleural thickening, and in both lungs for heart diseases, and diffuse pulmonary diseases including diffuse interstitial pneumonia and diffuse panbronchiolitis. The sum of (E-I)/I(+) of the both lungs, which correlated with vital capacity and PaO 2 , was decreased in diffuse interstitial pneumonia, pulmonary emphysema, diffuse panbronchiolitis, primary lung cancer, pleural diseases and so on. (E-I)/I(+), correlated with pulmonary perfusion (n=49, r=0.51, p 81m Kr or 133 Xe (n=49, r=0.61, p<0.001) than pulmonary perfusion. The ventilatory lung motion imaging, which demonstrates the motion of the intra-pulmonary areas and lung edges, appears useful for estimating pulmonary ventilation of the perfused area as well as pulmonary perfusion. (author)

  11. Regional assessment of treatment in lung cancer using lung perfusion and ventilation images

    International Nuclear Information System (INIS)

    Horikoshi, Masaki; Teshima, Takeo; Yanagimachi, Tomohiro; Ogata, Yuuko; Nukiwa, Toshihiro

    2000-01-01

    In 30 patients with lung cancer undergoing non-surgical treatment, we performed perfusion lung imaging using 99m Tc-MAA and inhalation lung studies using Technegas before and after treatment and evaluated regional perfusion and ventilation status in the lung regions where bronchogenic carcinoma was located. Regional ventilation status was preserved rather than perfusion counterpart (V>P) in 18 patients (18/30=60.0%) before treatment, while the former was better than the latter in 27 patients (27/30=90.0%) after treatment, indicating that regional ventilation status improved more significantly than regional perfusion counterpart after treatment (P=0.005). We also classified the therapeutic effect for regional perfusion and ventilation status as improved, unchanged, or worsened, respectively; improvement in regional perfusion status was observed in 17 patients (56.7%) and that in regional ventilation status in 24 patients (80.0%). There was a statistically significant correlation between improved regional perfusion and ventilation status (P=0.0018) when therapeutic effect was recognized. The patients who showed improvement in regional perfusion status after treatment always showed improved regional ventilation status, but 7 patients showed either unchanged or worsened regional perfusion status after treatment, although regional ventilation status was improved. In conclusion the pulmonary vascular beds seem more vulnerable to bronchogenic carcinoma and improvement in regional perfusion status was revealed to be more difficult than that in regional ventilation status after treatment. (author)

  12. A Short Period of Ventilation without Perfusion Seems to Reduce Atelectasis without Harming the Lungs during Ex Vivo Lung Perfusion

    Directory of Open Access Journals (Sweden)

    Sandra Lindstedt

    2013-01-01

    Full Text Available To evaluate the lung function of donors after circulatory deaths (DCDs, ex vivo lung perfusion (EVLP has been shown to be a valuable method. We present modified EVLP where lung atelectasis is removed, while the lung perfusion is temporarily shut down. Twelve pigs were randomized into two groups: modified EVLP and conventional EVLP. When the lungs had reached 37°C in the EVLP circuit, lung perfusion was temporarily shut down in the modified EVLP group, and positive end-expiratory pressure (PEEP was increased to 10 cm H2O for 10 minutes. In the conventional EVLP group, PEEP was increased to 10 cm H2O for 10 minutes with unchanged lung perfusion. In the modified EVLP group, the arterial oxygen partial pressure (PaO2 was 18.5 ± 7.0 kPa before and 64.5 ± 6.0 kPa after the maneuver (P<0.001. In the conventional EVLP group, the PaO2 was 16.8 ± 3.1 kPa and 46.8 ± 2.7 kPa after the maneuver (P<0.01; P<0.01. In the modified EVLP group, the pulmonary graft weight was unchanged, while in the conventional EVLP group, the pulmonary graft weight was significantly increased. Modified EVLP with normoventilation of the lungs without ongoing lung perfusion for 10 minutes may eliminate atelectasis almost completely without harming the lungs.

  13. Lung perfusion and ventilation scintigraphy in pre- and postoperative diagnostics

    International Nuclear Information System (INIS)

    Sandrock, D.; Munz, D.L.

    1998-01-01

    Lung perfusion (Tc-99m labeled albumin particles) and ventilation (Xe-133 gas) are used prior to thoracic surgery in order to evaluate changes in perfusion and ventilation due to the underlying diseases. Furthermore, perfusion scintigraphy allows combined with spirometry the prediction of the postinterventional vital capacity and the forced expiratory volume in 1 s. The correlation coefficient for this procedure compared with values measured postoperatively are in the range of 0.8. The method allows the assessment of operability in terms of postinterventional function. (orig.) [de

  14. Comparison of lung preservation solutions in human lungs using an ex vivo lung perfusion experimental model

    Directory of Open Access Journals (Sweden)

    Israel L. Medeiros

    2012-09-01

    Full Text Available OBJECTIVE: Experimental studies on lung preservation have always been performed using animal models. We present ex vivo lung perfusion as a new model for the study of lung preservation. Using human lungs instead of animal models may bring the results of experimental studies closer to what could be expected in clinical practice. METHOD: Brain-dead donors whose lungs had been declined by transplantation teams were used. The cases were randomized into two groups. In Group 1, Perfadex®was used for pulmonary preservation, and in Group 2, LPDnac, a solution manufactured in Brazil, was used. An ex vivo lung perfusion system was used, and the lungs were ventilated and perfused after 10 hours of cold ischemia. The extent of ischemic-reperfusion injury was measured using functional and histological parameters. RESULTS: After reperfusion, the mean oxygenation capacity was 405.3 mmHg in Group 1 and 406.0 mmHg in Group 2 (p = 0.98. The mean pulmonary vascular resistance values were 697.6 and 378.3 dyn·s·cm-5, respectively (p =0.035. The mean pulmonary compliance was 46.8 cm H20 in Group 1 and 49.3 ml/cm H20 in Group 2 (p =0.816. The mean wet/dry weight ratios were 2.06 and 2.02, respectively (p=0.87. The mean Lung Injury Scores for the biopsy performed after reperfusion were 4.37 and 4.37 in Groups 1 and 2, respectively (p = 1.0, and the apoptotic cell counts were 118.75/mm² and 137.50/mm², respectively (p=0.71. CONCLUSION: The locally produced preservation solution proved to be as good as Perfadex®. The clinical use of LPDnac may reduce costs in our centers. Therefore, it is important to develop new models to study lung preservation.

  15. Preparation and evaluation of (131I)AgI particles: potential lungs perfusion imaging agent

    International Nuclear Information System (INIS)

    Chattopadhyay, Sankha; Das, Sujata Saha; Sinha, Samarendu; Sarkar, Bharat Ranjan; Ganguly, Shantanu; Chandra, Susmita; De, Kakali; Mishra, Mridula

    2010-01-01

    Since the discovery of iodine-131 (t 1/2 : 8 d) by Livingood and Seaborg (1938), this, and other radioisotopes of iodine, have found widespread use in nuclear medicine. The purpose of the present work was to formulate Ag 131 I particles and bio-evaluate the same. The Ag 131 I particles were prepared in acidic condition having 100% R.C. Purity. The biological evaluation of Ag 131 1 particles was made by injecting about 111-185 MBq of Ag 131 I particles preparations in female albino rabbits (2-2.5 kg weight) intravenously by femoral vein under urethane anesthesia. Imaging studies were performed under Gamma Camera. The entire amount of the Ag 131 I particles were found to deposit in the lungs and remained there almost unchanged for a certain period of time after the intervenous administration. The images showed excellent, uniform lung uptake with no interference from liver and spleen to the lower regions of right and left lobes. It showed a high accumulation in the rabbits lungs (>99%) and remained constant for at least for 20 min. It is also worthy to study with 123 I/ 124 I labelled AgI for lung imaging study. In conclusion, the synthetic radiopharmaceutical ( 131 I)-Silver iodide colloid can be prepared with a large particle size, in a simple and practical manner, and it has good potential for use as a perfusion imaging agent in lung scans

  16. Uptake, incorporation and metabolism of (3H)triolein in the isolated perfused rabbit heart

    International Nuclear Information System (INIS)

    Weis, M.T.; Palazzo, A.J.; Williams, J.L. Jr.; Malik, K.U.

    1990-01-01

    The purpose of these experiments was to study the uptake and metabolism of exogenous triglyceride in the isolated perfused rabbit heart. When infused into the rabbit heart, [9,10-3H(N)]triolein was retained and incorporated into a lipid fraction that had the chromatographic mobility of authentic triolein. Incorporation of labeled triolein was not likely to be the result of a lipoprotein lipase-mediated lipolysis/resynthesis cycle, since: (i) The distribution of radioactivity following administration of [3H]oleic acid was markedly different from the distribution of radioactivity following the administration of [3H]triolein; (ii) heparin was administered to the rabbits at the time of sacrifice; and (iii) the hearts were perfused with a protein-free buffer for 20 min prior to the labelling period. When isoproterenol was administered to hearts labelled with [3H]triolein, there was an increased output of total radioactivity, composed of labelled free fatty acids, diacylglycerol and monoacylglycerol. In these same hearts, there was an increased output of glycerol in response to isoproterenol. However, following the administration of bradykinin or angiotensin II, neither the radioactivity nor the glycerol content of the perfusate was changed. These data suggest that [3H]triolein is selectively incorporated into the triglyceride pool of the isolated perfused rabbit heart. Furthermore, this [3H]triolein is available to hormonally-activated lipolytic enzymes

  17. Chest wall restriction limits high airway pressure-induced lung injury in young rabbits.

    Science.gov (United States)

    Hernandez, L A; Peevy, K J; Moise, A A; Parker, J C

    1989-05-01

    High peak inspiratory pressures (PIP) during mechanical ventilation can induce lung injury. In the present study we compare the respective roles of high tidal volume with high PIP in intact immature rabbits to determine whether the increase in capillary permeability is the result of overdistension of the lung or direct pressure effects. New Zealand White rabbits were assigned to one of three protocols, which produced different degrees of inspiratory volume limitation: intact closed-chest animals (CC), closed-chest animals with a full-body plaster cast (C), and isolated excised lungs (IL). The intact animals were ventilated at 15, 30, or 45 cmH2O PIP for 1 h, and the lungs of the CC and C groups were placed in an isolated lung perfusion system. Microvascular permeability was evaluated using the capillary filtration coefficient (Kfc). Base-line Kfc for isolated lungs before ventilation was 0.33 +/- 0.31 ml.min-1.cmH2O-1.100g-1 and was not different from the Kfc in the CC group ventilated with 15 cmH2O PIP. Kfc increased by 850% after ventilation with only 15 cmH2O PIP in the unrestricted IL group, and in the CC group Kfc increased by 31% after 30 cmH2O PIP and 430% after 45 cmH2O PIP. Inspiratory volume limitation by the plaster cast in the C group prevented any significant increase in Kfc at the PIP values used. These data indicate that volume distension of the lung rather than high PIP per se produces microvascular damage in the immature rabbit lung.

  18. Hypercapnic acidosis modulates inflammation, lung mechanics, and edema in the isolated perfused lung.

    Science.gov (United States)

    De Smet, Hilde R; Bersten, Andrew D; Barr, Heather A; Doyle, Ian R

    2007-12-01

    Low tidal volume (V(T)) ventilation strategies may be associated with permissive hypercapnia, which has been shown by ex vivo and in vivo studies to have protective effects. We hypothesized that hypercapnic acidosis may be synergistic with low V(T) ventilation; therefore, we studied the effects of hypercapnia and V(T) on unstimulated and lipopolysaccharide-stimulated isolated perfused lungs. Isolated perfused rat lungs were ventilated for 2 hours with low (7 mL/kg) or moderately high (20 mL/kg) V(T) and 5% or 20% CO(2), with lipopolysaccharide or saline added to the perfusate. Hypercapnia resulted in reduced pulmonary edema, lung stiffness, tumor necrosis factor alpha (TNF-alpha) and interleukin 6 (IL-6) in the lavage and perfusate. The moderately high V(T) did not cause lung injury but increased lavage IL-6 and perfusate IL-6 as well as TNF-alpha. Pulmonary edema and respiratory mechanics improved, possibly as a result of a stretch-induced increase in surfactant turnover. Lipopolysaccharide did not induce significant lung injury. We conclude that hypercapnia exerts a protective effect by modulating inflammation, lung mechanics, and edema. The moderately high V(T) used in this study stimulated inflammation but paradoxically improved edema and lung mechanics with an associated increase in surfactant release.

  19. Titanium Dioxide Exposure Induces Acute Eosinophilic Lung Inflammation in Rabbits

    Science.gov (United States)

    CHOI, Gil Soon; OAK, Chulho; CHUN, Bong-Kwon; WILSON, Donald; JANG, Tae Won; KIM, Hee-Kyoo; JUNG, Mannhong; TUTKUN, Engin; PARK, Eun-Kee

    2014-01-01

    Titanium dioxide (TiO2) is increasingly widely used in industrial, commercial and home products. TiO2 aggravates respiratory symptoms by induction of pulmonary inflammation although the mechanisms have not been well investigated. We aimed to investigate lung inflammation in rabbits after intratracheal instillation of P25 TiO2. One ml of 10, 50 and 250 µg of P25 TiO2 was instilled into one of the lungs of rabbits, chest computed-tomography was performed, and bronchoalveolar lavage (BAL) fluid was collected before, at 1 and 24 h after P25 TiO2 exposure. Changes in inflammatory cells in the BAL fluids were measured. Lung pathological assay was also carried out at 24 h after P25 TiO2 exposure. Ground glass opacities were noted in both lungs 1 h after P25 TiO2 and saline (control) instillation. Although the control lung showed complete resolution at 24 h, the lung exposed to P25 TiO2 showed persistent ground glass opacities at 24 h. The eosinophil counts in BAL fluid were significantly increased after P25 TiO2 exposure. P25 TiO2 induced a dose dependent increase of eosinophils in BAL fluid but no significant differences in neutrophil and lymphocyte cell counts were detected. The present findings suggest that P25 TiO2 induces lung inflammation in rabbits which is associated with eosinophilic inflammation. PMID:24705802

  20. Utilization of the organ care system as ex-vivo lung perfusion after cold storage transportation.

    Science.gov (United States)

    Mohite, P N; Maunz, O; Popov, A-F; Zych, B; Patil, N P; Simon, A R

    2015-11-01

    The Organ Care System (OCS) allows perfusion and ventilation of the donor lungs under physiological conditions. Ongoing trials to compare preservation with OCS Lung with standard cold storage do not include donor lungs with suboptimal gas exchange and donor lungs treated with OCS following cold storage transportation. We present a case of a 48-yr-old man who received such lungs after cold storage transportation treated with ex-vivo lung perfusion utilizing OCS. © The Author(s) 2015.

  1. Concentration of (+/-)-propranolol in isolated, perfused lungs of rat.

    Science.gov (United States)

    Dollery, C T; Junod, A F

    1976-01-01

    1 The metabolism and the accumulation of (+/-)-propranolol have been studied in isolated lungs of the rat, perfused with an artificial medium. 2 Little or no metabolism took place during the perfusion periods (up to 10 minutes). 3 Accumulation was observed with high tissue/medium ratios for substrate concentrations of 0.2 muM to 1 mM; there was evidence for saturability, but no real plateau could be seen. The presence of two binding sites with different affinities was established. 4 Cold greatly inhibited the accumulation process at low substrate concentrations, but had no effect at 1 mM propranolol. 5 Inhibition of accumulation was measured in the presence of imipramine, desmethylimipramine, nortryptiline, chlorpromazine and of Na+-free medium. Cocaine, 5-hydroxytryptamine and noradrenaline had no effect. Lidocaine enhanced the accumulation process. Release of previously bound propranolol was accelerated in the presence of propranolol and imipramine, unaffected by a Na+-free medium and decreased by cold and by lidocaine. 6 Experiments on lung tissue slices yielded qualitatively similar results to those obtained with perfused lungs. Ouabain and KCN had no or little effect on propranolol accumulation. PMID:1276542

  2. Simultaneous measurement of pO2 and perfusion in the rabbit kidney in vivo.

    Science.gov (United States)

    O'Connor, Paul M; Anderson, Warwick P; Kett, Michelle M; Evans, Roger G

    2007-01-01

    Recently, a combined probe has been developed capable of simultaneous measurement of local tissue pO2 (fluorescence oximetry) and microvascular perfusion (laser Doppler flux) within the same local region. The aim of the current study was to test the utility of these combined probes to measure pO2 and perfusion in the kidney. Studies were performed in anesthetized, artificially ventilated rabbits (n=7). Baseline measurements of renal medullary perfusion and pO2 obtained using combined probes (537 +/- 110 units & 28.7 +/- 6.l mmHg, respectively) were indistinguishable from those obtained using independent probes (435 +/- 102 units & 26.9 +/- 6.4 mmHg). Baseline measurements of renal cortical pO2 were also similar between combined (9.7 +/- 1.6 mmHg) and independent probes (9.5 +/- 2.3 mmHg). Baseline levels of cortical perfusion however, were significantly greater when measured using independent probes (1130 +/- 114 units) compared to combined probes (622 +/- 59 units; P pO2 resulting from graded stimulation of the renal nerves were not significantly different when measured using combined probes to those obtained using independent probes. We conclude that combined probes are equally suitable to independent probes for tissue pO2 and microvascular perfusion measurement in the kidney. Our results raise some concerns regarding the accuracy of these OxyLite fluorescence probes for pO2 measurement in the kidney, particularly within the renal cortex.

  3. Detection of reactive oxygen species in isolated, perfused lungs by electron spin resonance spectroscopy

    Directory of Open Access Journals (Sweden)

    Schudt Christian

    2005-07-01

    Full Text Available Abstract Background The sources and measurement of reactive oxygen species (ROS in intact organs are largely unresolved. This may be related to methodological problems associated with the techniques currently employed for ROS detection. Electron spin resonance (ESR with spin trapping is a specific method for ROS detection, and may address some these technical problems. Methods We have established a protocol for the measurement of intravascular ROS release from isolated buffer-perfused and ventilated rabbit and mouse lungs, combining lung perfusion with the spin probe l-hydroxy-3-carboxy-2,2,5,5-tetramethylpyrrolidine (CPH and ESR spectroscopy. We then employed this technique to characterize hypoxia-dependent ROS release, with specific attention paid to NADPH oxidase-dependent superoxide formation as a possible vasoconstrictor pathway. Results While perfusing lungs with CPH over a range of inspired oxygen concentrations (1–21 %, the rate of CP• formation exhibited an oxygen-dependence, with a minimum at 2.5 % O2. Addition of superoxide dismutase (SOD to the buffer fluid illustrated that a minor proportion of this intravascular ROS leak was attributable to superoxide. Stimulation of the lungs by injection of phorbol-12-myristate-13-acetate (PMA into the pulmonary artery caused a rapid increase in CP• formation, concomitant with pulmonary vasoconstriction. Both the PMA-induced CPH oxidation and the vasoconstrictor response were largely suppressed by SOD. When the PMA challenge was performed at different oxygen concentrations, maximum superoxide liberation and pulmonary vasoconstriction occurred at 5 % O2. Using a NADPH oxidase inhibitor and NADPH-oxidase deficient mice, we illustrated that the PMA-induced superoxide release was attributable to the stimulation of NADPH oxidases. Conclusion The perfusion of isolated lungs with CPH is suitable for detection of intravascular ROS release by ESR spectroscopy. We employed this technique to

  4. Relations between CT perfusion parameters and degree of hepatic ischemia reperfusion injury in a rabbit model

    International Nuclear Information System (INIS)

    Guo Chengwei; Shen Sandi; Yi Xianlin; Zhang Zhonglin; Liu Zaiyi; Liang Changhong

    2011-01-01

    Objective: To observe the changes of hepatic CT perfusion parameters and their correlation with serum aspartate transaminase (AST), alanine transaminase (ALT) and alkaline phosphatase (ALP) in a rabbit hepatic ischemia reperfusion injury (IRI) model. Methods: Hepatic IRI was produced in rabbits by inducing left liver lobe ischemia (60 min) followed by 6 h, 12 h and 24 h reperfusion (6 rabbits were used for each reperfusion interval). Additional 6 rabbits were served as sham-operated controls. All the rabbits were scanned with a dynamic iCT protocol. Blood samples were taken from the superior mesenteric vein to measure the levels of serum amylase (ALT, AST, and ALP) in various groups, and liver samples were taken for histological examinations after scanning. One-way analysis of variance (ANOVA) was used to determine differences between groups. The correlations of CT perfusion parameters with serum levels were analyzed using Pearson correlation coefficient. Results: Heterogeneity of CT perfusion patterns appeared in the 6 h groups, which presented as low enhanced area [(25.1±9.3) ml · min -1 · 100 mg -1 ]. In reduced perfusion regions of IRI group, HAP of 12 h IRI group [(19.5± 13.6) ml · min -1 · 100 mg -1 ], 24 h IRI group (8.0±2.7) ml · min -1 · 100 mg -1 ], HPP of 6 h IRI group [(10.8±5.5) ml · min -1 · 100 mg -1 ], 12 h IRI group [(14.4±5.2) ml · min -1 · 100 mg -1 ] , 24 h IRI group [(7.8±3.3) ml · min -1 · 100 mg -1 ] and TLP of 6 h IRI group [(35.9±14.0) ml · min -1 · 100 mg -1 ], 12 h IRI group [(33.9±16.1) ml · min -1 · 100 mg -1 ], 24 h IRI group [(16.0± 5.5) ml · min -1 · 100 mg -1 ] were lower than those of sham group [HAP (21.2±10.5) ml · min -1 · 100 mg -1 , HPP (63.5±24.0) ml · min -1 · 100 mg -1 , TLP (81.4±24.8) ml · min -1 · 100 mg -1 ] (F=8.376, 25.950, 16.925, P<0.01). However, HPI of 6 h IRI group [(65.9±3.9)%], 12 h IRI group [(54.2±16.7)%], and 24 h IRI group [(48.9±10.0)%] were higher compared to sham

  5. Counting the mismatches - lung ventilation/perfusion subtraction index

    International Nuclear Information System (INIS)

    Anderson, T.C.; Evans, S.G.; Larcos, G.; Farlow, D.C.

    1998-01-01

    Full text: There is potential for interobserver variability in interpretation of ventilation/perfusion (V/Q) scans. Objective quantification of V/Q mismatch could be useful. Thus, the aim of this study is to determine the validity of image subtraction in a group of 27 patients (11 men, 8 women; mean age 59.4 years [range 21-81 years])investigated by V/Q scans for suspected pulmonary emboli. A standard 6 view V/Q scan was obtained with two cobalt markers used on the anterior and posterior surfaces for image alignment. Ventilation images were normalised to the perfusion using an area of normal ventilation and perfusion. With the use of automated, and if required, manual alignment, perfusion images were subtracted from ventilation, with a median filter applied. A summed index of mismatch for each lung scan was calculated from the difference. This index was then retrospectively compared to the result reported by one of four experienced physicians. Two patients with chronic obstructive airways disease were excluded from analysis. We conclude that high probability V/Q scans can be differentiated from low probability studies using this index; further prospective investigation in a larger cohort is warranted

  6. Quantitative study on lung volume and lung perfusion using SPECT and CT in thoracal tumors

    International Nuclear Information System (INIS)

    Beyer-Enke, S.A.; Goerich, J.; Strauss, L.G.

    1988-01-01

    22 patients with space occupying lesions in the thoracal region were investigated by computer tomography and by perfusion scintigraphy using SPECT. In order to evaluate the CT images quantitatively, the lung volume was determined using approximation method and compared with the perfusion in the SPECT study. For this, anatomically equivalent transaxial SPECT slices had been coordinated to the CT slices. Between the determined lung volumes and the activity in the ocrresponding layers, a statistically significant correlation was found. It could be shown that the stronger perfusion, frequently observed at the right side of the healthy lung, may be explained by an higher volume of the right pulmonary lobe. Whereas in benign displacing processes the relation activity to volume was similar to the one of the healthy lung, a strongly reduced perfusion together with inconspicuous lung volumes became apparent with malignant tumors. In addition to the great morphological evidence of CT and SPECT studies, additional informations regarding the dignity of displacing processes may be derived from the quantitative evaluation of both methods. (orig.) [de

  7. First Danish experience with ex vivo lung perfusion of donor lungs before transplantation

    DEFF Research Database (Denmark)

    Henriksen, Ian Sune Iversen; Møller-Sørensen, Hasse; Møller, Christian Holdfold

    2014-01-01

    INTRODUCTION: The number of lung transplantations is limited by a general lack of donor organs. Ex vivo lung perfusion (EVLP) is a novel method to optimise and evaluate marginal donor lungs prior to transplantation. We describe our experiences with EVLP in Denmark during the first year after its...... introduction. MATERIAL AND METHODS: The study was conducted by prospective registration of donor offers and lung transplantations in Denmark from 1 May 2012 to 30 April 2013. Donor lungs without any contraindications were transplanted in the traditional manner. Taken for EVLP were donor lungs that were...... otherwise considered transplantable, but failed to meet the usual criteria due to possible contusions or because they were from donors with sepsis or unable to pass the oxygenation test. RESULTS: In the study period, seven of 33 Danish lung transplantations were made possible due to EVLP. One patient died...

  8. Measurement of lung volume by lung perfusion scanning using SPECT and prediction of postoperative respiratory function

    International Nuclear Information System (INIS)

    Andou, Akio; Shimizu, Nobuyosi; Maruyama, Shuichiro

    1992-01-01

    Measurement of lung volume by lung perfusion scanning using single photon emission computed tomography (SPECT) and its usefulness for the prediction of respiratory function after lung resection were investigated. The lung volumes calculated in 5 patients by SPECT (threshold level 20%) using 99m Tc-macroaggregated albumin (MAA), related very closely to the actually measured lung volumes. This results prompted us to calculate the total lung volume and the volume of the lobe to be resected in 18 patients with lung cancer by SPECT. Based on the data obtained, postoperative respiratory function was predicted. The predicted values of forced vital capacity (FVC), forced expiratory volume (FEV 1.0 ), and maximum vital volume (MVV) showed closer correlations with the actually measured postoperative values (FVC, FEV 1.0 , MVV : r=0.944, r=0.917, r=0.795 respectively), than the values predicted by the ordinary lung perfusion scanning. This method facilitates more detailed evaluation of local lung function on a lobe-by-lobe basis, and can be applied clinically to predict postoperative respiratory function. (author)

  9. Comparison of lung protective ventilation strategies in a rabbit model of acute lung injury.

    Science.gov (United States)

    Rotta, A T; Gunnarsson, B; Fuhrman, B P; Hernan, L J; Steinhorn, D M

    2001-11-01

    To determine the impact of different protective and nonprotective mechanical ventilation strategies on the degree of pulmonary inflammation, oxidative damage, and hemodynamic stability in a saline lavage model of acute lung injury. A prospective, randomized, controlled, in vivo animal laboratory study. Animal research facility of a health sciences university. Forty-six New Zealand White rabbits. Mature rabbits were instrumented with a tracheostomy and vascular catheters. Lavage-injured rabbits were randomized to receive conventional ventilation with either a) low peak end-expiratory pressure (PEEP; tidal volume of 10 mL/kg, PEEP of 2 cm H2O); b) high PEEP (tidal volume of 10 mL/kg, PEEP of 10 cm H2O); c) low tidal volume with PEEP above Pflex (open lung strategy, tidal volume of 6 mL/kg, PEEP set 2 cm H2O > Pflex); or d) high-frequency oscillatory ventilation. Animals were ventilated for 4 hrs. Lung lavage fluid and tissue samples were obtained immediately after animals were killed. Lung lavage fluid was assayed for measurements of total protein, elastase activity, tumor necrosis factor-alpha, and malondialdehyde. Lung tissue homogenates were assayed for measurements of myeloperoxidase activity and malondialdehyde. The need for inotropic support was recorded. Animals that received a lung protective strategy (open lung or high-frequency oscillatory ventilation) exhibited more favorable oxygenation and lung mechanics compared with the low PEEP and high PEEP groups. Animals ventilated by a lung protective strategy also showed attenuation of inflammation (reduced tracheal fluid protein, tracheal fluid elastase, tracheal fluid tumor necrosis factor-alpha, and pulmonary leukostasis). Animals treated with high-frequency oscillatory ventilation had attenuated oxidative injury to the lung and greater hemodynamic stability compared with the other experimental groups. Both lung protective strategies were associated with improved oxygenation, attenuated inflammation, and

  10. Isoflurane administration before ischemia and during reperfusion attenuates ischemia/reperfusion-induced injury of isolated rabbit lungs.

    Science.gov (United States)

    Liu, R; Ishibe, Y; Ueda, M; Hang, Y

    1999-09-01

    To investigate the effects of isoflurane on ischemia/ reperfusion (IR)-induced lung injury, we administered isoflurane before ischemia or during reperfusion. Isolated rabbit lungs were divided into the following groups: control (n = 6), perfused and ventilated for 120 min without ischemia; ISO-control (n = 6), 1 minimum alveolar anesthetic concentration (MAC) isoflurane was administered for 30 min before 120 min continuous perfusion; IR (n = 6), ischemia for 60 min, followed by 60 min reperfusion; IR-ISO1 and IR-ISO2, ischemia followed by reperfusion and 1 MAC (n = 6) or 2 MAC (n = 6) isoflurane for 60 min; ISO-IR (n = 6), 1 MAC isoflurane was administered for 30 min before ischemia, followed by IR. During these maneuvers, we measured total pulmonary vascular resistance (Rt), coefficient of filtration (Kfc), and lung wet to dry ratio (W/D). The results indicated that administration of isoflurane during reperfusion inhibited an IR-induced increase in Kfc and W/D ratio. Furthermore, isoflurane at 2 MAC, but not 1 MAC, significantly inhibited an IR-induced increase in Rt. The administration of isoflurane before ischemia significantly attenuated the increase in IR-induced Kfc, W/D, and Rt. Our results suggest that the administration of isoflurane before ischemia and during reperfusion protects against ischemia-reperfusion-induced injury in isolated rabbit lungs.

  11. The effect of irradiation on lung function and perfusion in patients with lung cancer

    International Nuclear Information System (INIS)

    Abratt, Raymond P.; Willcox, Paul A.

    1995-01-01

    Purpose: To prospectively study the changes in lung function in patients with lung carcinoma treated with relatively high doses of irradiation. Methods and Materials: Lung function was assessed prior to and at 6 and 12 months following radiation therapy by a clinical dyspnea score, formal pulmonary function tests (lung volume spirometry and diffusion capacity) as well as an ipsilateral hemithorax lung perfusion scan. Changes in dyspnea score were evaluated by the chi-square and the Fishers exact test. Changes in formal lung function tests were compared with the t-test for dependent data and correlations with the t-test for independent data. Fifty-one patients were entered into the study. There were 42 evaluable patients at 6 months after irradiation and 22 evaluable patients at 12 months after irradiation. Results: A worsening of dyspnea score from 1 to 2, which is clinically acceptable, occurred in 50% or more of patients. However, a dyspnea score of 3, which is a serious complication, developed in only 5% of patients. The diffusion capacity (DLCO) decreased by 14% at 6 months and 12% at 12 months) (p < 0.0001). The forced vital capacity and total lung capacity decreased between 6% and 8% at 6 month and 12 months, which was statistically significant. The forced expiratory volume in 1 s decreased between 2 and 3% at 6 month and 12 months, which was not statistically significant. The ipsilateral hemithorax perfusion decreased by 17 and 20% at 6 and 12 months (p < 0.0001). There was no correlation between the initial hemithorax perfusion, or its decrease at follow up and the decrease in DLCO. Conclusion: Lung irradiation results in some loss of lung function in patients with lung cancer with a projected survival of 6 months or more. The pretreatment DLCO assessment should be useful in predicting clinical tolerance to irradiation

  12. Ethamsylate and lung permeability in ventilated immature newborn rabbits.

    Science.gov (United States)

    Amato, M; Sun, B; Robertson, B

    1994-01-01

    The leakage of proteins in the immature neonatal lung can reduce the effect of exogenous surfactant. The effect of ethamsylate, a more specific prostaglandin inhibitor than indomethacin and aspirin-like drugs, on alveolar albumin leak was studied in a group of 27 immature newborn rabbits (gestational age 27 days). A pilot study was carried out using 4 animals and low-dose ethamsylate (10 mg/kg). A second group of animals (n = 12) received at birth, by intravenous injection, ethamsylate (50 mg/kg) and 10% human albumin (7 ml/kg). Animals not receiving ethamsylate (n = 11) served as control group. After 30 min of artificial ventilation with standard tidal volume (10 ml/kg) the lungs were lavaged and the amount of human albumin in lung lavage fluid was determined by immunodiffusion. No statistically significant differences were found in lung-thorax compliance and vascular to alveolar albumin leak between ethamsylate-treated animals and controls (p > 0.5). However, there was a statistically significant negative correlation between protein leak and lung compliance (r = -0.41; p ethamsylate administration on neonatal lung permeability in the immature neonate confirming that lung permeability is inversely related to compliance.

  13. Study of regional lung ventilation and perfusion by xenon 133

    International Nuclear Information System (INIS)

    Lombard, Yves.

    1976-01-01

    The present work consists of a regional lung exploration after injection of xenon 133, dissolved in physiological serum, followed a few minutes later by that of 99m Tc-labelled serumalbumin microspheres. The aim is three fold: first of all to study perfusion and ventilation by xenon 133, next to compare the results obtained after xenon 133 and 99 m Tc-labelled microsphere injection, lastly to establish the value of the technique and its routine application. This examination has not solved all problems of lung exploration by xenon 133. For example we deliberately kept to intraveinous injection of the gas dissolved in physiological serum, leaving aside the breathing test. Xenon 133 scintigraphy in our opinion will not tend to replace 99m Tc-labelled microsphere scintigraphy, which has irreplaceable morphological qualities, but will serve as an excellent complement. The basic advantage of xenon 133 is the regional ventilation estimate it provides allowing any anomaly of the lung parenchyma to be located immediately or conversely the functional value of the healthy lung to be established with a view to a surgical removal of a diseased zone [fr

  14. Application of CT perfusion imaging in radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Xia Guangrong; Liu Guimei; He Wen; Jin Guohua; Xie Ruming; Xu Yongxiang; Li Xiaobo; Li Xuebing

    2011-01-01

    Objective: To investigate the value of CT perfusion imaging in evaluation of therapeutic effect and prognosis in radiotherapy for lung cancer. Methods: Fifty-one cases of lung cancer who were unable or refused to be operated on, 36 males and 15 females, aged 37-80, underwent CT perfusion imaging, 29 of which only before radiotherapy and 22 before and after radiotherapy twice. The images were collected by cine dynamic scanning (5 mm/4 slices) and input into the GE AW4.0 workstation for data processing. The slice positions of CT imaging were determined according to the largest tumor size in CT scan. Regions of interest of tumor were drawn at the region corresponding to the original images of CT perfusion. Radiotherapy was performed after CT perfusion imaging. Relevant parameters, including blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface (PS) were calculated. The treatment response after radiotherapy was evaluated by RECIST. At 2 -4 weeks after the treatment, CT examination was conducted once more. Results: The tests of the 51 patients showed that the BV was 13.6 ml·100 g -1 , the BF was 129.5 ml·min -1 ·100 g -1 , the MTT was 9.1 s, and the PS was 10.0 ml· min -1 · 100 g -1 before radiotherapy. The tests of the 22 of the 51 patients showed that the values of BV and BF after radiotherapy were 7.6 ml· 100 g -1 and 97.8 ml·min -1 · 100 g -1 , respectively, both lower than those before radiotherapy (11.2 and 108.7 ml·min -1 ·100 g -1 , respectively), however, both not significantly (t=1.28, 0.40, P>0.05); and the values of MTT and PS after radiotherapy were 8.9 s and 7.8 ml·min -1 · 100 g -1 , respectively, both not significantly higher than those before radiotherapy (7.2 s and 6.8 ml· min -1 · 100 g -1 , respectively, t=-1.15, -0.57, P>0.05). The mean area of tumor after radiotherapy was 1189.6 mm 2 , significantly less than that before radiotherapy (1920.3 mm 2 , t=3.98, P<0.05). The MTT of the SCLC patients was 12

  15. Ex vivo lung perfusion in clinical lung transplantation--state of the art.

    Science.gov (United States)

    Andreasson, Anders S I; Dark, John H; Fisher, Andrew J

    2014-11-01

    Ex vivo lung perfusion (EVLP) has emerged as a new technique for assessing and potentially reconditioning human donor lungs previously unacceptable for clinical transplantation with the potential to dramatically push the limits of organ acceptability. With the recent introduction of portable EVLP, a new era in lung preservation may be upon us with the opportunity to also limit organ ischaemic times and potentially improve the outcome of donor lungs already deemed acceptable for transplantation. It took over half a century for the technique to evolve from basic theory to semi-automated circuits fit for clinical use that are now rapidly being adopted in transplant centres across the globe. With this field in constant evolution and many unanswered questions remaining, our review serves as an update on the state of the art of EVLP in clinical lung transplantation. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  16. First Danish experience with ex vivo lung perfusion of donor lungs before transplantation

    DEFF Research Database (Denmark)

    Henriksen, Ian Sune Iversen; Møller-Sørensen, Hasse; Møller, Christian Holdfold

    2014-01-01

    INTRODUCTION: The number of lung transplantations is limited by a general lack of donor organs. Ex vivo lung perfusion (EVLP) is a novel method to optimise and evaluate marginal donor lungs prior to transplantation. We describe our experiences with EVLP in Denmark during the first year after its...... otherwise considered transplantable, but failed to meet the usual criteria due to possible contusions or because they were from donors with sepsis or unable to pass the oxygenation test. RESULTS: In the study period, seven of 33 Danish lung transplantations were made possible due to EVLP. One patient died......% improved oxygenation. The median time to extubation, time in intensive care unit and the admission period were 1, 7 and 39 days, respectively. CONCLUSION: In the first year after the introduction of EVLP in Denmark, seven pairs of donor lungs that previously would have been rejected have been transplanted...

  17. Decreased Lung Perfusion After Breast/Chest Wall Irradiation: Quantitative Results From a Prospective Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Liss, Adam L., E-mail: adamliss68@gmail.com [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Marsh, Robin B. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Kapadia, Nirav S. [Department of Radiation Oncology, Dartmouth Hitchcock Medical Center, Lebanon, New Hampshire (United States); McShan, Daniel L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Rogers, Virginia E. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M.; Moran, Jean M.; Brock, Kristy K.; Schipper, Matt J.; Jagsi, Reshma [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Griffith, Kent A. [Biostatistics Unit, University of Michigan, Ann Arbor, Michigan (United States); Flaherty, Kevin R. [Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan (United States); Frey, Kirk A. [Division of Nuclear Medicine, Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Pierce, Lori J. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2017-02-01

    Purpose: To quantify lung perfusion changes after breast/chest wall radiation therapy (RT) using pre- and post-RT single photon emission computed tomography/computed tomography (SPECT/CT) attenuation-corrected perfusion scans; and correlate decreased perfusion with adjuvant RT dose for breast cancer in a prospective clinical trial. Methods and Materials: As part of an institutional review board–approved trial studying the impact of RT technique on lung function in node-positive breast cancer, patients received breast/chest wall and regional nodal irradiation including superior internal mammary node RT to 50 to 52.2 Gy with a boost to the tumor bed/mastectomy scar. All patients underwent quantitative SPECT/CT lung perfusion scanning before RT and 1 year after RT. The SPECT/CT scans were co-registered, and the ratio of decreased perfusion after RT relative to the pre-RT perfusion scan was calculated to allow for direct comparison of SPECT/CT perfusion changes with delivered RT dose. The average ratio of decreased perfusion was calculated in 10-Gy dose increments from 0 to 60 Gy. Results: Fifty patients had complete lung SPECT/CT perfusion data available. No patient developed symptoms consistent with pulmonary toxicity. Nearly all patients demonstrated decreased perfusion in the left lung according to voxel-based analyses. The average ratio of lung perfusion deficits increased for each 10-Gy increment in radiation dose to the lung, with the largest changes in regions of lung that received 50 to 60 Gy (ratio 0.72 [95% confidence interval 0.64-0.79], P<.001) compared with the 0- to 10-Gy region. For each increase in 10 Gy to the left lung, the lung perfusion ratio decreased by 0.06 (P<.001). Conclusions: In the assessment of 50 patients with node-positive breast cancer treated with RT in a prospective clinical trial, decreased lung perfusion by SPECT/CT was demonstrated. Our study allowed for quantification of lung perfusion defects in a prospective cohort of

  18. Arterio-venous anastomoses in isolated, perfused rat lungs.

    Science.gov (United States)

    Conhaim, Robert L; Segal, Gilad S; Watson, Kal E

    2016-11-01

    Several studies have suggested that large-diameter (>25 μm) arterio-venous shunt pathways exist in the lungs of rats, dogs, and humans. We investigated the nature of these pathways by infusing specific-diameter fluorescent latex particles (4, 7, 15, 30, or 50 μm) into isolated, ventilated rat lungs perfused at constant pressure. All lungs received the same mass of latex (5 mg), which resulted in infused particle numbers that ranged from 1.7 × 10 7 4 μm particles to 7.5 × 10 4 50 μm particles. Particles were infused over 2 min. We used a flow cytometer to count particle appearances in venous effluent samples collected every 0.5 min for 12 min from the start of particle infusion. Cumulative percentages of infused particles that appeared in the samples averaged 3.17 ± 2.46% for 4 μm diameter particles, but ranged from 0.01% to 0.17% for larger particles. Appearances of 4 μm particles followed a rapid upslope beginning at 30 sec followed by a more gradual downslope that lasted for up to 12 min. All other particle diameters also began to appear at 30 sec, but followed highly irregular time courses. Infusion of 7 and 15 μm particles caused transient but significant perfusate flow reductions, while infusion of all other diameters caused insignificant reductions in flow. We conclude that small numbers of bypass vessels exist that can accommodate particle diameters of 7-to-50 μm. We further conclude that our 4 μm particle data are consistent with a well-developed network of serial and parallel perfusion pathways at the acinar level. Published 2016. This article is a U.S. Government work and is in the public domain in the USA. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  19. Common-path Fourier domain optical coherence tomography of irradiated human skin and ventilated isolated rabbit lungs

    Science.gov (United States)

    Popp, A.; Wendel, M.; Knels, L.; Knuschke, P.; Mehner, M.; Koch, T.; Boller, D.; Koch, P.; Koch, E.

    2005-08-01

    A compact common path Fourier domain optical coherence tomography (FD-OCT) system based on a broadband superluminescence diode is used for biomedical imaging. The epidermal thickening of human skin after exposure to ultraviolet radiation is measured to proof the feasibility of FD-OCT for future substitution of invasive biopsies in a long term study on natural UV skin protection. The FD-OCT system is also used for imaging lung parenchyma. FD-OCT images of a formalin fixated lung show the same alveolar structure as scanning electron microscopy images. In the ventilated and blood-free perfused isolated rabbit lung FD-OCT is used for real-time cross-sectional image capture of alveolar mechanics throughout tidal ventilation. The alveolar mechanics changing from alternating recruitment-derecruitment at zero positive end-expiratory pressure (PEEP) to persistent recruitment after applying a PEEP of 5 cm H2O is observed in the OCT images.

  20. Uptake of exogenous spermidine by rat lungs perfused in situ

    International Nuclear Information System (INIS)

    Rannels, D.E.; Addison, J.L.

    1987-01-01

    Uptake of the polyamine spermidine (SPD) from the pulmonary circulation was characterized by using ventilated rat lungs perfused in situ with Krebs-Henseleit-bicarbonate buffer containing 4.5% bovine serum albumin, 5.6 mM glucose, and 20 amino acids at plasma levels. [ 14 C]SPD was accumulated by the lungs in a time- and concentration-dependent manner. The pathway of SPD uptake exhibited saturation kinetics with an apparent K/sub m/ in the range of 1 μM and a V/sub max/ of 450-540 pmol/g lung min. SPD uptake was inhibited by the naturally occurring polyamines putrescine and spermine (SPM) and by the inhibitor of polyamine synthesis, methyglyoxal bis(guanylhydrazone) (MGBG). Inhibition of SPD uptake by SPM followed competitive kinetics; although MGBG was also a competitive inhibitor of SPD uptake, MGBG was less effective than SPM. These observations indicate that SPD is taken up from the pulmonary circulation by a carrier-mediated pathway that is inhibited by other natural polyamines and by MGBG and exhibits by other natural polyamines and by MGBG and exhibits substrate affinity in the range of plasma SPD concentrations

  1. Uptake of exogenous spermidine by rat lungs perfused in situ

    Energy Technology Data Exchange (ETDEWEB)

    Rannels, D.E.; Addison, J.L.

    1987-01-01

    Uptake of the polyamine spermidine (SPD) from the pulmonary circulation was characterized by using ventilated rat lungs perfused in situ with Krebs-Henseleit-bicarbonate buffer containing 4.5% bovine serum albumin, 5.6 mM glucose, and 20 amino acids at plasma levels. (/sup 14/C)SPD was accumulated by the lungs in a time- and concentration-dependent manner. The pathway of SPD uptake exhibited saturation kinetics with an apparent K/sub m/ in the range of 1 ..mu..M and a V/sub max/ of 450-540 pmol/g lung min. SPD uptake was inhibited by the naturally occurring polyamines putrescine and spermine (SPM) and by the inhibitor of polyamine synthesis, methyglyoxal bis(guanylhydrazone) (MGBG). Inhibition of SPD uptake by SPM followed competitive kinetics; although MGBG was also a competitive inhibitor of SPD uptake, MGBG was less effective than SPM. These observations indicate that SPD is taken up from the pulmonary circulation by a carrier-mediated pathway that is inhibited by other natural polyamines and by MGBG and exhibits by other natural polyamines and by MGBG and exhibits substrate affinity in the range of plasma SPD concentrations.

  2. Effect of re-expansion after short-period lung collapse on pulmonary capillary permeability and pro-inflammatory cytokine gene expression in isolated rabbit lungs.

    Science.gov (United States)

    Funakoshi, T; Ishibe, Y; Okazaki, N; Miura, K; Liu, R; Nagai, S; Minami, Y

    2004-04-01

    Re-expansion pulmonary oedema is a rare complication caused by rapid re-expansion of a chronically collapsed lung. Several cases of pulmonary oedema associated with one-lung ventilation (OLV) have been reported recently. Elevated levels of pro-inflammatory cytokines in pulmonary oedema fluid are suggested to play important roles in its development. Activation of cytokines after re-expansion of collapsed lung during OLV has not been thoroughly investigated. Here we investigated the effects of re-expansion of the collapsed lung on pulmonary oedema formation and pro-inflammatory cytokine expression. Lungs isolated from female white Japanese rabbits were perfused and divided into a basal (BAS) group (n=7, baseline measurement alone), a control (CONT) group (n=9, ventilated without lung collapse for 120 min) and an atelectasis (ATEL) group (n=9, lung collapsed for 55 min followed by re-expansion and ventilation for 65 min). Pulmonary vascular resistance (PVR) and the coefficient of filtration (Kfc) were measured at baseline and 60 and 120 min. At the end of perfusion, bronchoalveolar lavage fluid/plasma protein ratio (B/P), wet/dry lung weight ratio (W/D) and mRNA expressions of tumour necrosis factor (TNF)-alpha, interleukin (IL)-1beta and myeloperoxidase (MPO) were determined. TNF-alpha and IL-1beta mRNA were significantly up-regulated in lungs of the ATEL group compared with BAS and CONT, though no significant differences were noted in PVR, Kfc, B/P and W/D within and between groups. MPO increased at 120 min in CONT and ATEL groups. Pro-inflammatory cytokines were up-regulated upon re-expansion and ventilation after short-period lung collapse, though no changes were noted in pulmonary capillary permeability.

  3. Quantitative dual energy CT measurements in rabbit VX2 liver tumors: Comparison to perfusion CT measurements and histopathological findings

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wu, Shengyong; Wang, Mei; Lu, Li; Chen, Bo; Jin, Lixin; Wang, Jiandong; Larson, Andrew C.; Lu, Guang Ming

    2012-01-01

    Purpose: To evaluate the correlation between quantitative dual energy CT and perfusion CT measurements in rabbit VX2 liver tumors. Materials and methods: This study was approved by the institutional animal care and use committee at our institution. Nine rabbits with VX2 liver tumors underwent contrast-enhanced dual energy CT and perfusion CT. CT attenuation for the tumors and normal liver parenchyma and tumor-to-liver ratio were obtained at the 140 kVp, 80 kVp, average weighted images and dual energy CT iodine maps. Quantitative parameters for the viable tumor and adjacent liver were measured with perfusion CT. The correlation between the enhancement values of the tumor in iodine maps and perfusion CT parameters of each tumor was analyzed. Radiation dose from dual energy CT and perfusion CT was measured. Results: Enhancement values for the tumor were higher than that for normal liver parenchyma at the hepatic arterial phase (P < 0.05). The highest tumor-to-liver ratio was obtained in hepatic arterial phase iodine map. Hepatic blood flow of the tumor was higher than that for adjacent liver (P < 0.05). Enhancement values of hepatic tumors in the iodine maps positively correlated with permeability of capillary vessel surface (r = 0.913, P < 0.001), hepatic blood flow (r = 0.512, P = 0.010), and hepatic blood volume (r = 0.464, P = 0.022) at the hepatic arterial phases. The effective radiation dose from perfusion CT was higher than that from DECT (P < 0.001). Conclusions: The enhancement values for viable tumor tissues measured in iodine maps were well correlated to perfusion CT measurements in rabbit VX2 liver tumors. Compared with perfusion CT, dual energy CT of the liver required a lower radiation dose.

  4. Comparing CT perfusion with oxygen partial pressure in a rabbit VX2 soft-tissue tumor model.

    Science.gov (United States)

    Sun, Chang-Jin; Li, Chao; Lv, Hai-Bo; Zhao, Cong; Yu, Jin-Ming; Wang, Guang-Hui; Luo, Yun-Xiu; Li, Yan; Xiao, Mingyong; Yin, Jun; Lang, Jin-Yi

    2014-01-01

    The aim of this study was to evaluate the oxygen partial pressure of the rabbit model of the VX2 tumor using a 64-slice perfusion CT and to compare the results with that obtained using the oxygen microelectrode method. Perfusion CT was performed for 45 successfully constructed rabbit models of a VX2 brain tumor. The perfusion values of the brain tumor region of interest, the blood volume (BV), the time to peak (TTP) and the peak enhancement intensity (PEI) were measured. The results were compared with the partial pressure of oxygen (PO2) of that region of interest obtained using the oxygen microelectrode method. The perfusion values of the brain tumor region of interest in 45 successfully constructed rabbit models of a VX2 brain tumor ranged from 1.3-127.0 (average, 21.1 ± 26.7 ml/min/ml); BV ranged from 1.2-53.5 ml/100g (average, 22.2 ± 13.7 ml/100g); PEI ranged from 8.7-124.6 HU (average, 43.5 ± 28.7 HU); and TTP ranged from 8.2-62.3 s (average, 38.8 ± 14.8 s). The PO2 in the corresponding region ranged from 0.14-47 mmHg (average, 16 ± 14.8 mmHg). The perfusion CT positively correlated with the tumor PO2, which can be used for evaluating the tumor hypoxia in clinical practice.

  5. Scintigraphic and MR perfusion imaging in preoperative evaluation for lung volume reduction surgery. Pilot study results

    International Nuclear Information System (INIS)

    Johkoh, Takeshi; Mueller, N.L.; Kavanagh, P.V

    2000-01-01

    To compare MR perfusion imaging with perfusion scintigraphy in the evaluation of patients with pulmonary emphysema being considered for lung volume reduction surgery. Six patients with pulmonary emphysema and two normal individuals were evaluated by MR perfusion imaging, perfusion scintigraphy, and selective bilateral pulmonary angiography. MR images were obtained with an enhanced fast gradient recalled echo with three-dimensional Fourier transformation technique (efgre 3D) (6.3/1.3; flip angle, 30 deg C; field of view, 45-48 cm; matrix, 256 x 160). The presence or absence of perfusion defects in each segment was evaluated by two independent observers. Using angiography as the gold standard, the sensitivity, specificity, and accuracy of MR perfusion imaging in detecting focal perfusion abnormalities were 90%, 87%, and 89%, respectively, while those of perfusion scintigraphy were 71%, 76%, and 71%, respectively. The diagnostic accuracy of MR perfusion imaging was significantly higher than that of scintigraphy (p<0.001, McNemar test). There was good agreement between two observers for MR perfusion imaging (kappa statistic, 0.66) and only moderate agreement for perfusion scintigraphy (kappa statistic, 0.51). MR perfusion imaging is superior to perfusion scintigraphy in the evaluation of pulmonary parenchymal perfusion in patients with pulmonary emphysema. (author)

  6. Effects of Constant Flow vs. Constant Pressure Perfusion on Fluid Filtration in Severe Hypothermic Isolated Blood-Perfused Rat Lungs.

    Science.gov (United States)

    Halsøy, Kathrine; Kondratiev, Timofey; Tveita, Torkjel; Bjertnaes, Lars J

    2016-01-01

    Victims of severe accidental hypothermia are prone to fluid extravasation but rarely develop lung edema. We hypothesize that combined hypothermia-induced increase in pulmonary vascular resistance (PVR) and a concomitant fall in cardiac output protect the lungs against edema development. Our aim was to explore in hypothermic-isolated blood-perfused rat lungs whether perfusion at constant pressure influences fluid filtration differently from perfusion at constant flow. Isolated blood-perfused rat lungs were hanging freely in a weight transducer for measuring weight changes (ΔW). Fluid filtration coefficient (Kfc), was determined by transiently elevating left atrial pressure (Pla) by 5.8 mmHg two times each during normothermia (37°C) and during hypothermia (15°C). The lung preparations were randomized to two groups. One group was perfused with constant flow (Constant flow group) and the other group with constant pulmonary artery pressure (Constant PPA group). Microvascular pressure (Pmv) was determined before and during elevation of Pla (ΔPmv) by means of the double occlusion technique. Kfc was calculated with the formula Kfc = ΔW/ΔPmv/min. All Kfc values were normalized to predicted lung weight (P LW ), which was based on body weight (BW) according to the formula: P LW  = 0.0053 BW - 0.48 and presented as Kfc PLW in mg/min/mmHg/g. At cessation, bronchoalveolar lavage (BAL) fluid/perfusate protein concentration (B/P) ratio was determined photometrically. Data were analyzed with parametric or non-parametric tests as appropriate. p  Kfc PLW and B/P ratio increased significantly by more than 10-fold during hypothermia concerted by visible signs of edema in the trachea. Hemoglobin and hematocrit increased within the Constant flow group and between the groups at cessation of the experiments. In hypothermic rat lungs perfused at constant flow, fluid filtration coefficient per gram P LW and B/P ratio increased more than 10-fold concerted by increased

  7. The Rabbit as a Model for Studying Lung Disease and Stem Cell Therapy

    OpenAIRE

    Kamaruzaman, Nurfatin Asyikhin; Kardia, Egi; Kamaldin, Nurulain ‘Atikah; Latahir, Ahmad Zaeri; Yahaya, Badrul Hisham

    2013-01-01

    No single animal model can reproduce all of the human features of both acute and chronic lung diseases. However, the rabbit is a reliable model and clinically relevant facsimile of human disease. The similarities between rabbits and humans in terms of airway anatomy and responses to inflammatory mediators highlight the value of this species in the investigation of lung disease pathophysiology and in the development of therapeutic agents. The inflammatory responses shown by the rabbit model, e...

  8. Dynamic volume perfusion CT in patients with lung cancer: Baseline perfusion characteristics of different histological subtypes

    International Nuclear Information System (INIS)

    Shi, Jingyun; Schmid-Bindert, Gerald; Fink, Christian; Sudarski, Sonja; Apfaltrer, Paul; Pilz, Lothar R.; Liu, Bo; Haberland, Ulrike; Klotz, Ernst

    2013-01-01

    Objective: To evaluate dynamic volume perfusion CT (dVPCT) tumor baseline characteristics of three different subtypes of lung cancer in untreated patients. Materials and methods: 173 consecutive patients (131 men, 42 women; mean age 61 ± 10 years) with newly diagnosed lung cancer underwent dVPCT prior to biopsy. Tumor permeability, blood flow (BF), blood volume (BV) and mean transit time (MTT) were quantitatively assessed as well as tumor diameter and volume. Tumor subtypes were histologically determined and compared concerning their dVPCT results. dVPCT results were correlated to tumor diameter and volume. Results: Histology revealed adenocarcinoma in 88, squamous cell carcinoma in 54 and small cell lung cancer (SCLC) in 31 patients. Tumor permeability was significantly differing between adenocarcinoma, squamous cell carcinoma and SCLC (all p < 0.05). Tumor BF and BV were higher in adenocarcinomathan in SCLC (p = 0.001 and p = 0.0002 respectively). BV was also higher in squamous cell carcinoma compared to SCLC (p = 0.01). MTT was not differing between tumor subtypes. Regarding all tumors, tumor diameter did not correlate with any of the dVPCT parameters, whereas tumor volume was negatively associated with permeability, BF and BV (r = −0.22, −0.24, −0.24, all p < 0.05). In squamous cell carcinoma, tumor diameter und volume correlated with BV (r = 0.53 and r = −0.40, all p < 0.05). In SCLC, tumor diameter und volume correlated with MTT (r = 0.46 and r = 0.39, all p < 0.05). In adenocarcinoma, no association between morphological and functional tumor characteristics was observed. Conclusions: dVPCT parameters are only partially related to tumor diameter and volume and are significantly differing between lung cancer subtypes

  9. Lung perfusion SPECT in predicting postoperative pulmonary function in lung cancer

    International Nuclear Information System (INIS)

    Hirose, Yoshiaki; Imaeda, Takeyoshi; Doi, Hidetaka; Kokubo, Mitsuharu; Sakai, Satoshi; Hirose, Hajime

    1993-01-01

    The aim of this prospective study is to evaluate the availability of preoperative perfusion SPECT in predicting postoperative pulmonary function following resection. Twenty-three patients with lung cancer who were candidates for lobectomy were investigated preoperatively with spirometry, x-ray computed tomography and 99m Tc-macroaggregated albumin SPECT. Their postoperative pulmonary functions were predicted with these examinations. The forced vital capacity and the forced expiratory volume in one second were selected as parameters for overall pulmonary function. The postoperative pulmonary function was predicted by the following formula: Predicted postoperative value=observed preoperative value x precent perfusion of the lung not to be resected. The patients were reinvestigated with spirometry at 3 months and 6 months after lobectomy, and the values obtained were statistically compared with the predicted values. Close relationships were found between predicted and observed forced vital capacity (r=0.87, p<0.001), and predicted and observed forced expiratory volume in one second (r=0.90, p<0.001). The accurate prediction of pulmonary function after lobectomy could be achieved by means of lung perfusion SPECT. (author)

  10. Estimation of pulmonary hypertension in lung and valvular heart diseases by perfusion lung scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige [Shinshu Univ., Matsumoto, Nagano (Japan). School of Allied Medical Sciences; Tanaka, Masao; Yazaki, Yoshikazu; Kitabayashi, Hirosi; Koizumi, Tomonori; Kubo, Keisi; Sekiguchi, Morie; Yano, Kesato

    1999-06-01

    To estimate pulmonary hypertension, we measured postural differences in pulmonary blood flow for the lateral decubitus positions on perfusion lung scintigrams with Tc-99 m macro-aggregated albumin, applying the method devised by Tanaka et al (Eur J Nucl Med 17: 320-326, 1990). Utilizing a scintillation camera coupled to a minicomputer system, changes in the distribution of pulmonary blood flow caused by gravitational effects, namely, changes in the total count ratios for the right lung versus the left lung in the right and left lateral decubitus positions (R/L), were obtained for 44 patients with lung disease, 95 patients with valvular heart disease, and 23 normal subjects. Mean standard deviation in the R/L ratios was 3.09{+-}1.28 for the normal subjects, 1.97{+-}0.89 for the patients with lung disease, and 1.59{+-}0.59 for the patients with valvular heart disease. The R/L ratios correlated with mean pulmonary arterial pressure and cardio-thoracic ratios in the lung disease and valvular heart disease groups, with pulmonary arteriolar resistance in the former, and with pulmonary capillary wedge pressure in the latter. Defining pulmonary hypertension (>20 mmHg) as an R/L ratio of less than 1.81, which is the mean-1 standard deviation for normal subjects, the sensitivity and the specificity of the R/L ratio for the diagnosis of pulmonary hypertension were 62.9% and 76.2%, respectively, for the lung disease patients, and 80.3% and 61.8%, respectively, for the valvular heart disease patients. This method seems to be useful for the pathophysiologic evaluation of pulmonary perfusion in cases of lung disease and valvular heart disease. (author)

  11. Organotypic lung culture: A new model for studying ischemia and ex vivo perfusion in lung transplantation.

    Science.gov (United States)

    Baste, Jean-Marc; Gay, Arnaud; Smail, Hassiba; Noël, Romain; Bubenheim, Michael; Begueret, Hugues; Morin, Jean-Paul; Litzler, Pierre-Yves

    2015-01-01

    Donors after cardiac death (DCD) in lung transplantation is considered as a solution for organ shortage. However, it is characterized by warm ischemic period, which could be involved in severe Ischemia-Reperfusion lesion (IR) with early graft dysfunction. We describe a new hybrid model combining in vivo ischemia followed by in vitro reoxygenation using organ-specific culture. A hybrid model using in vivo ischemic period followed by in vitro lung slice reoxygenation was set up in rat to mimic DCD in lung transplantation with in vitro perfusion. Different markers (bioenergetics, oxidant stress assays, and histology) were measured to evaluate the viability of lung tissue after different ischemic times (I-0, I-1, I-2, I-4, I-15 hours) and reoxygenation times (R-0, R-1, R-4, R-24 hours). No differences were found in cell viability, ATP concentrations, extracellular LDH assays or histology, demonstrating extensive viability of up to 4 hours in lung tissue warm ischemia. We found oxidative stress mainly during the ischemic period with no burst at reoxygenation. Cytosolic anti-oxidant system was involved first (I-0,I-1,I-2) followed by mitochondrial anti-oxidant system for extensive ischemia (I-4). Histological features showed differences in this model of ischemia-reoxygenation between bronchial epithelium and lung parenchymal cells, with epithelium regeneration after 2 hours of warm ischemia and 24 hours of perfusion. The results of our hybrid model experiment suggest extensive lung viability of up to 4 hours ischemia. Our model could be an interesting tool to evaluate ex vivo reconditioning techniques after different in vivo lung insults.

  12. Estimation of pulmonary hypertension in lung and valvular heart diseases by perfusion lung scintigraphy

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Yazaki, Yoshikazu; Kitabayashi, Hirosi; Koizumi, Tomonori; Kubo, Keisi; Sekiguchi, Morie; Yano, Kesato

    1999-01-01

    To estimate pulmonary hypertension, we measured postural differences in pulmonary blood flow for the lateral decubitus positions on perfusion lung scintigrams with Tc-99 m macro-aggregated albumin, applying the method devised by Tanaka et al (Eur J Nucl Med 17: 320-326, 1990). Utilizing a scintillation camera coupled to a minicomputer system, changes in the distribution of pulmonary blood flow caused by gravitational effects, namely, changes in the total count ratios for the right lung versus the left lung in the right and left lateral decubitus positions (R/L), were obtained for 44 patients with lung disease, 95 patients with valvular heart disease, and 23 normal subjects. Mean standard deviation in the R/L ratios was 3.09±1.28 for the normal subjects, 1.97±0.89 for the patients with lung disease, and 1.59±0.59 for the patients with valvular heart disease. The R/L ratios correlated with mean pulmonary arterial pressure and cardio-thoracic ratios in the lung disease and valvular heart disease groups, with pulmonary arteriolar resistance in the former, and with pulmonary capillary wedge pressure in the latter. Defining pulmonary hypertension (>20 mmHg) as an R/L ratio of less than 1.81, which is the mean-1 standard deviation for normal subjects, the sensitivity and the specificity of the R/L ratio for the diagnosis of pulmonary hypertension were 62.9% and 76.2%, respectively, for the lung disease patients, and 80.3% and 61.8%, respectively, for the valvular heart disease patients. This method seems to be useful for the pathophysiologic evaluation of pulmonary perfusion in cases of lung disease and valvular heart disease. (author)

  13. Evaluation of 99mTc(CO)5I as a potential lung perfusion agent

    International Nuclear Information System (INIS)

    Miroslavov, Alexander E.; Gorshkov, Nikolay I.; Lumpov, Alexander L.; Yalfimov, Anatoly N.; Suglobov, Dmitrii N.; Ellis, Beverley L.; Braddock, Rattana; Smith, Anne-Marie; Prescott, Mary C.; Lawson, Richard S.; Sharma, Harbans L.

    2009-01-01

    Introduction: The use of 99m Tc-macroggregated albumin for lung perfusion imaging is well established in nuclear medicine. However, there have been safety concerns over the use of blood-derived products because of potential contamination by infective agents, for example, Variant Creutzfeldt Jakob Disease. Preliminary work has indicated that Tc(CO) 5 I is primarily taken up in the lungs following intravenous administration. The aim of this study was to evaluate the biodistribution and pharmacokinetics of 99m Tc(CO) 5 I and its potential as a lung perfusion agent. Methods: 99m Tc(CO) 5 I was synthesized by carbonylation of 99m TcO 4- at 160 atm of CO at 170 deg. C in the presence of HI for 40 min. Radiochemical purity was determined by HPLC using 99 Tc(CO) 5 I as a reference. 99m Tc(CO) 5 I was administered by ear-vein injection to three chinchilla rabbits, and dynamic images were acquired using a gamma camera (Siemens E-cam) over 20 min. Imaging studies were also performed with 99m Tc-labeled macroaggregated albumin ( 99m Tc-MAA) and 99m TcO 4- for comparison. 99m Tc(CO) 5 I was administered intravenously to Sprague-Dawley rats, and tissue distribution studies were obtained at 15 min and 1 h postinjection. Comparative studies were performed using 99m Tc-MAA. Results: Radiochemical purity, assessed by HPLC, was 98%. The retention time was similar to that of 99 Tc(CO) 5 I. The dynamic images showed that 70% of 99m Tc(CO) 5 I appeared promptly in the lungs and remained constant for at least 20 min. In contrast, 99m TcO 4- rapidly washed out of the lungs after administration. As expected 99m Tc-MAA showed 90% lung accumulation. The percentage of injected dose per gram of organ ±S.D. at 1 h for 99m Tc(CO) 5 I was as follows: blood, 0.22±0.02; lung, 12.8±2.87; liver, 0.8±0.15; heart, 0.15±0.01; kidney, 0.47±0.08. The percentage of injected dose per organ ±S.D. at 1 h was as follows: lung, 22.47±2.31; liver, 10.53±1.8; heart, 0.18±0.01; kidney, 1.2±0.17. Tissue

  14. Kinetics of reversible-sequestration of leukocytes by the isolated perfused rat lung

    Energy Technology Data Exchange (ETDEWEB)

    Goliaei, B.

    1980-08-01

    The kinetics and morphology of sequestration and margination of rat leukocytes were studied using an isolated perfused and ventilated rat lung preparation. Whole rat blood, bone marrow suspension, or leukocyte suspensions, were used to perfuse the isolated rat lung. The lung was also perfused with latex particle suspensions and the passage of particles through the lung capillaries was studied. When a leukocyte suspension was perfused through the lung in the single-pass mode, the rate of sequestration decreased as more cells were perfused. In contrast, latex particles of a size comparable to that of leukocytes were totally stopped by the lung. When the leukocyte suspension was recirculated through the lung, cells were rapidly removed from circulation until a steady state was reached, after which no net removal of cells by the lung occurred. These results indicate that leukocytes are reversibly sequestered from circulation. The sequestered cells marginated and attached to the luminal surface of the endothelium of post-capillary venules and veins. A mathematical model was developed based on the assumption that the attachment and detachment of leukocytes to blood vessel walls follows first-order kinetics. The model correctly predicts the following characteristics of the system: (a) the kinetics of the sequestration of leukocytes by the lung; (b) the existence of a steady state when a suspension of leukocytes is recirculated through the lung; and (c) the independence of the fraction of cells remaining in circulation from the starting concentration for all values of starting concentration. (ERB)

  15. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F.; Becker, Christoph R. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Hacker, Marcus [Department of Nuclear Medicine, Ludwig-Maximilians-University of Munich (Germany); Nikolaou, Konstantin; Reiser, Maximilian F. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Johnson, Thorsten R.C. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany)], E-mail: thorsten.johnson@med.uni-muenchen.de

    2008-12-15

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam.

  16. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    International Nuclear Information System (INIS)

    Thieme, Sven F.; Becker, Christoph R.; Hacker, Marcus; Nikolaou, Konstantin; Reiser, Maximilian F.; Johnson, Thorsten R.C.

    2008-01-01

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam

  17. Perfusion lung scintigraphy in primary broncho-pulmonary cancer

    International Nuclear Information System (INIS)

    Lapergue, Paul.

    1976-01-01

    Research on primary broncho-pulmonary cancer has called extensively on scintigraphy and it seemed interesting to weigh up the pros and cons of the technique in this particular case. Our intention is to sum up objectively from recent documents the applications of scintigraphy in the study of primary broncho-pulmonary cancers and to attempt, on the basis of the results compiled, to show what benefits have been gained from this technique and to find out whether it has any pre-surgical value and of what kind. The technique was invariable; the tracer consists of human albumin macro-aggregates labelled with technetium 99m which by its short half-life and slight penetration enables four exposures to be taken during the same examination (front, back, right and left profiles), thus reducing the risks of mistaken diagnoses due to the use of a single incidence. Similarly the detection method was always the scintillation camera which explores the whole organ at once, considerably shortening the examination time. Lung scintigraphy by perfusion of labelled human albumin macro-aggregates offers the great advantage of being simple to use and harmless. It is easy to understand the important place it has taken in the range of methods available for lung circulation exploration [fr

  18. Water permeability of acinar cell membranes in the isolated perfused rabbit mandibular salivary gland.

    Science.gov (United States)

    Steward, M C; Seo, Y; Rawlings, J M; Case, R M

    1990-01-01

    1. The diffusive water permeability of epithelial cell membranes in the perfused rabbit mandibular salivary gland was measured at 37 degrees C by a 1H nuclear magnetic resonance relaxation method using an extracellular relaxation reagent, gadolinium diethylenetriaminepentaacetic acid (Gd(DTPA)). 2. In glands perfused with a HEPES-buffered solution containing 10 mmol l-1 Gd(DTPA), the spin-lattice (T1) relaxation of the water protons showed two exponential components. The water compartment responsible for the slower component corresponded in magnitude to 71 +/- 5% of the wet weight of the gland, and was attributed to the exchangeable intracellular water of the acinar cells. 3. The rate constant for water efflux from the cells was estimated to be 4.1 +/- 0.1 s-1 which would be consistent with a diffusive membrane permeability (Pd) of approximately 3 x 10(-3) cm s-1. Stimulation with acetylcholine (10(-6) mol l-1) did not cause any detectable change in membrane water permeability. 4. Since the basolateral membrane probably provides the main pathway for water efflux, the osmotic water permeability of this barrier (expressed per gland) was estimated to be less than 6.2 cm3 s-1. This would be insufficient to account for the generation of a near-isosmotic fluid at the flow rates observed during secretion, and suggests that a substantial fraction of the flow of water occurs via a paracellular route. PMID:1966053

  19. Paraquat-poisoning in the rabbit lungs: high resolution computed tomographic findings and pathologic correlation

    International Nuclear Information System (INIS)

    Lee, Kyung Soo; Kim, Eui Han; Lee, Byoung Ho; Kim, Kun Sang

    1992-01-01

    The authors evaluated high resolution computed tomographic (HRCT) findings of the isolated rabbit lungs with paraquat poisoning, and the findings were correlated with pathologic specimens. The purposes of this study are 1) to obtain the HRCT findings of the normal rabbit lung. 2) to find out if pulmonary pathology can be induced in rabbits by paraquat, and 3) to correlate the HRCT findings to those of pathology. Thirty rabbits were divided into three groups: group I included four control rabbits; group II included 16 rabbits given paraquat intraperitoneally (IP group); and group III included 10 rabbits given paraquat intravenously (IV group). The rabbits were sacrificed seven, 10, and 14 days after injection of various amount of paraquat, and then the lungs were isolated for HRCT and pathologic studies. Gross and microscopic findings of the three groups of control and paraquat-injected rabbit lungs were correlated with HRCT findings. Pulmonary congestion, mild thickening of alveolar walls and septae, and multifocal micro-atelectasis were the man pathologic findings of the lungs in both groups of the rabbits. Pulmonary hemorrhage was noted in five (31%) of 16 rabbits of IP group and three (30%) of 10 IV group. Pulmonary edema was seen in one rabbits (6%) of IP and four (40%) of IV group. Typical pulmonary fibrosis was seen in one rabbit of IP (6%) and IV (10%) group, respectively. There was no correlation between the amount of paraquat and frequency of the pulmonary pathology. Pulmonary fibrosis was seen at least one week after the paraquat injection. On HRCT, pulmonary hemorrhage and edema appeared as diffuse air-space consolidation and pulmonary fibrosis as linear or band-like opacities. However, minimal changes such as mild congestion

  20. Prediction of residual lung function after lung surgery, and examination of blood perfusion in the pre- and postoperative lung using three-dimensional SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Shimatani, Shinji [Toho Univ., Tokyo (Japan). School of Medicine

    2001-01-01

    In order to predict postoperative pulmonary function after lung surgery, preoperative {sup 99m}Tc-macroaggregated albumin (MAA) lung perfusion scans with single-photon emission computed tomography (SPECT) were performed. Spirometry was also performed before and 4-6 months after surgery in 40 patients. In addition, changes in blood perfusion in the pre- and postoperative lung were examined by postoperative lung perfusion scans in 18 of the 40 patients. We measured the three-dimensional (3-D) imaging volume of the operative and contralateral lungs using the volumes rendering method at blood perfusion thresholds of 20, 50 and 75%, utilizing {sup 99m}Tc-MAA lung perfusion, and predicted pulmonary function by means of the measured volumes. We examined the correlation between predicted and the measured values of postoperative pulmonary function, forced vital capacity (FVC) and forced expiratory volume in one second (FEV{sub 1.0}). The correlation between FEV{sub 1.0} predicted by SPECT (threshold 50%) and measured postoperative lung function resembled that between lung function predicted by the standard planar method and measured FEV{sub 1.0} in the lobectomy group. We then examined the ratios of both pre- and postoperative blood perfusion volumes obtained using 3-D imaging at lung perfusion threshold ranges of 10% each (PV20-29, PV30-39) to pre- and postoperative total perfusion (PV20-100). In the lobectomy group, the postoperative PV20-29/PV20-100 value was significantly higher for the operative side lung than the preoperative PV20-29/PV20-100 value, and the postoperative PV50-59, 60-69, 70-79, 80-89 and 90-100/PV20-100 values were significantly lower than the respective preoperative values. However, in the contralateral lung, the respective pre- and postoperative PV/PV20-100 values were almost identical. These findings suggest that the rate of low blood perfusion increased while the rate of middle to high perfusion decreased in the lobectomy group in the operative

  1. Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis - initial results

    International Nuclear Information System (INIS)

    Eichinger, Monika; Puderbach, Michael; Zuna, Ivan; Kauczor, Hans-Ulrich; Fink, Christian; Gahr, Julie; Mueller, Frank-Michael; Ley, Sebastian; Plathow, Christian; Tuengerthal, Siegfried

    2006-01-01

    This paper is a feasibility study of magnetic resonance imaging (MRI) of lung perfusion in children with cystic fibrosis (CF) using contrast-enhanced 3D MRI. Correlation assessment of perfusion changes with structural abnormalities. Eleven CF patients (9 f, 2 m; median age 16 years) were examined at 1.5 T. Morphology: HASTE coronal, transversal (TR/TE/α/ST: 600 ms/28 ms/180 /6 mm), breath-hold 18 s. Perfusion: Time-resolved 3D GRE pulse sequence (FLASH, TE/TR/α: 0.8/1.9 ms/40 ), parallel imaging (GRAPPA, PAT 2). Twenty-five data sets were acquired after intravenous injection of 0.1 mmol/kg body weight of gadodiamide, 3-5 ml/s. A total of 198 lung segments were analyzed by two radiologists in consensus and scored for morphological and perfusion changes. Statistical analysis was performed by Mantel-Haenszel chi-square test. Results showed that perfusion defects were observed in all patients and present in 80% of upper, and 39% of lower lobes. Normal lung parenchyma showed homogeneous perfusion (86%, P<0.0001). Severe morphological changes led to perfusion defects (97%, P<0.0001). Segments with moderate morphological changes showed normal (53%) or impaired perfusion (47%). In conclusion, pulmonary perfusion is easy to judge in segments with normal parenchyma or severe changes. In moderately damaged segments, MRI of lung perfusion may help to better assess actual functional impairment. Contrast-enhanced 3D MRI of lung perfusion has the potential for early vascular functional assessment and therapy control in CF patients. (orig.)

  2. Histogram based analysis of lung perfusion of children after congenital diaphragmatic hernia repair.

    Science.gov (United States)

    Kassner, Nora; Weis, Meike; Zahn, Katrin; Schaible, Thomas; Schoenberg, Stefan O; Schad, Lothar R; Zöllner, Frank G

    2018-05-01

    To investigate a histogram based approach to characterize the distribution of perfusion in the whole left and right lung by descriptive statistics and to show how histograms could be used to visually explore perfusion defects in two year old children after Congenital Diaphragmatic Hernia (CDH) repair. 28 children (age of 24.2±1.7months; all left sided hernia; 9 after extracorporeal membrane oxygenation therapy) underwent quantitative DCE-MRI of the lung. Segmentations of left and right lung were manually drawn to mask the calculated pulmonary blood flow maps and then to derive histograms for each lung side. Individual and group wise analysis of histograms of left and right lung was performed. Ipsilateral and contralateral lung show significant difference in shape and descriptive statistics derived from the histogram (Wilcoxon signed-rank test, phistogram derived parameters. Histogram analysis can be a valuable tool to characterize and visualize whole lung perfusion of children after CDH repair. It allows for several possibilities to analyze the data, either describing the perfusion differences between the right and left lung but also to explore and visualize localized perfusion patterns in the 3D lung volume. Subgroup analysis will be possible given sufficient sample sizes. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. First Danish experience with ex vivo lung perfusion of donor lungs before transplantation.

    Science.gov (United States)

    Henriksen, Ian Sune Iversen; Møller-Sørensen, Hasse; Møller, Christian Holdfold; Zemtsovski, Mikhail; Nilsson, Jens Christian; Seidelin, Casper Tobias; Perch, Michael; Iversen, Martin; Steinbrüchel, Daniel

    2014-03-01

    The number of lung transplantations is limited by a general lack of donor organs. Ex vivo lung perfusion (EVLP) is a novel method to optimise and evaluate marginal donor lungs prior to transplantation. We describe our experiences with EVLP in Denmark during the first year after its introduction. The study was conducted by prospective registration of donor offers and lung transplantations in Denmark from 1 May 2012 to 30 April 2013. Donor lungs without any contraindications were transplanted in the traditional manner. Taken for EVLP were donor lungs that were otherwise considered transplantable, but failed to meet the usual criteria due to possible contusions or because they were from donors with sepsis or unable to pass the oxygenation test. In the study period, seven of 33 Danish lung transplantations were made possible due to EVLP. One patient died of non-EVLP-related causes, but all other recipients were alive with normal graft function at the end of our registration period. All lungs showed an improved PaO2/FiO2 ratio from a median 23.1 kPa (8.8-38.9) within the donor to 58.8 kPa (34.9-76.5) (FiO2 = 1.0) after EVLP, which corresponds to a 155% improved oxygenation. The median time to extubation, time in intensive care unit and the admission period were 1, 7 and 39 days, respectively. In the first year after the introduction of EVLP in Denmark, seven pairs of donor lungs that previously would have been rejected have been transplanted as a result of their improved function. EVLP seems to be a safe way to increase the use of marginal donor lungs. no funding was granted for the present paper. not relevant.

  4. Graft downsizing during ex vivo lung perfusion: case report and technical notes.

    Science.gov (United States)

    Nosotti, M; Rosso, L; Mendogni, P; Tosi, D; Palleschi, A; Righi, I; Froio, S; Valenza, F; Santambrogio, L

    2014-09-01

    Among patients with respiratory insufficiency awaiting lung transplantation, small adult patients have a lower opportunity of receiving size-matched pulmonary grafts, because of the shortage of donors, particularly those of small size. Reducing the size of an oversized graft is one of the methods to increase the donor pool; similarly, ex vivo lung perfusion is an emerging technique aimed toward the same purpose. We describe how we combined the 2 techniques (lobar transplantation plus contralateral nonanatomic graft reduction during ex vivo lung perfusion) to overcome graft shortage in a clinical case. For the 1st time, this case report demonstrates that surgical manipulation during ex vivo lung perfusion does not affect the functional improvement in a lung previously judged to be not suitable for transplantation. The 6-month follow-up results are similar to those of standard bilateral lung transplantation. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Ventilation and Perfusion Lung Scintigraphy of Allergen-Induced Airway Responses in Atopic Asthmatic Subjects

    Directory of Open Access Journals (Sweden)

    Krishnan Parameswaran

    2007-01-01

    Full Text Available BACKGROUND: Both ventilation (V and perfusion (Q of the lungs are altered in asthma, but their relationships with allergen-induced airway responses and gas exchange are not well described.

  6. Effects of smoking on lung uptake of 201Tl during exercise myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Ouyang Wei; He Guorong; Liu Jinhua

    2004-01-01

    Objective: To investigate the influence of smoking on lung uptake of 201 Tl during myocardial perfusion imaging. Methods: Ninety-two healthy subjects, with normal 201 Tl myocardial perfusion imaging findings but no evidence of left ventricular hypertrophy and pulmonary disease, were divided into three groups, smoker, nonsmoker and quitted smoker groups. Exercise/delay 201 Tl myocardial perfusion imaging was performed on all subjects included. Lung/heart ratio was defined on the anterior planar image obtained during exercise tomography. Results: Both the lung/heart ratios during exercise in smoker (0.40 ± 0.07, F=10.635, P 201 Tl lung/heart ratios in smokers are higher than in nonsmokers and this must be kept in mind when 201 Tl lung/heart ratios are used clinically, even in quitted smokers

  7. Comparing CT perfusion with oxygen partial pressure in a rabbit VX2 soft-tissue tumor model

    International Nuclear Information System (INIS)

    Sun Changjin; Li Chao; Lv Haibo

    2014-01-01

    The aim of this study was to evaluate the oxygen partial pressure of the rabbit model of the VX2 tumor using a 64-slice perfusion CT and to compare the results with that obtained using the oxygen microelectrode method. Perfusion CT was performed for 45 successfully constructed rabbit models of a VX2 brain tumor. The perfusion values of the brain tumor region of interest, the blood volume (BV), the time to peak (TTP) and the peak enhancement intensity (PEI) were measured. The results were compared with the partial pressure of oxygen (PO2) of that region of interest obtained using the oxygen microelectrode method. The perfusion values of the brain tumor region of interest in 45 successfully constructed rabbit models of a VX2 brain tumor ranged from 1.3–127.0 (average, 21.1 ± 26.7 ml/min/ml); BV ranged from 1.2–53.5 ml/100g (average, 22.2 ± 13.7 ml/100g); PEI ranged from 8.7–124.6 HU (average, 43.5 ± 28.7 HU); and TTP ranged from 8.2–62.3 s (average, 38.8 ± 14.8 s). The PO2 in the corresponding region ranged from 0.14–47 mmHg (average, 16 ± 14.8 mmHg). The perfusion CT positively correlated with the tumor PO2, which can be used for evaluating the tumor hypoxia in clinical practice. (author)

  8. Time and dose-related changes in lung perfusion after definitive radiotherapy for NSCLC

    DEFF Research Database (Denmark)

    Farr, Katherina P; Khalil, Azza A; Møller, Ditte S

    2018-01-01

    BACKGROUND AND PURPOSE: To examine radiation-induced changes in regional lung perfusion per dose level in 58 non-small-cell lung cancer (NSCLC) patients treated with intensity-modulated radiotherapy (IMRT). MATERIAL AND METHODS: NSCLC patients receiving chemo-radiotherapy (RT) of minimum 60 Gy we...

  9. Role of radio-aerosol and perfusion lung imaging in early detection of chronic obstructive lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Garg, A; Pande, J N; Guleria, J S; Gopinath, P G

    1983-04-01

    The efficacy of radio-aerosol and perfusion lung imaging in the early detection of chronic obstructive lung disease was evaluated in 38 subjects. The subjects included 5 non-smokers, 21 smokers with minimal or no respiratory symptoms and 12 patients with chronic obstructive lung disease. Each subject consented to a respiratory questionaire, detailed physical examination, chest X-ray examinations, detailed pulmonary function tests and sup(99m)Tc-radioaerosol-inhalation lung imaging. Perfusion lung imaging with sup(99m)Tc-labelled macroaggregated albumin was performed in 22 subjects. A significant correlation (P<0.001) was observed between the degree of abnormalities on radio-aerosol imaging and pulmonary function tests (PFTs) including forced expiratory volume in 1 s, maximum midexpiratory flow rate and mean transit time analysis. Abnormal radio-aerosol patterns and deranged PFTs were observed in 21 subjects each. Of 21 subjects with abnormal radioaerosol pattern 8 had normal PFTs. Of 21 subjects with abnormal PFTs 8 had normal aerosol images. Aerosol lung images and PFTs were abnormal more frequently than perfusion lung images. The results suggest that radio-aerosol lung imaging is as sensitive an indicator as PFTs for early detection of chronic obstructive lung disease and can be usefully combined with PFTs for early detection of alteration in pulmonary physiology in smokers.

  10. Regional distribution of perfusion and ventilation in hamartoangiomyomatosis of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Tominaga, Shigeru; Ohsaka, Tomohisa; Nanbu, Masashi; Toyoda, Keiko; Mori, Yutaka; Kawakami, Kenji; Inatomi, Keiko; Kira, Shiro

    1989-01-01

    We investigated regional distribution of perfusion and ventilation in three cases of hamartoangiomyomatosis (HAM) by /sup 133/Xe gas and /sup 99m/Tc-MAA. In two cases, /sup 133/Xe washout were dominantly delayed in middle lung field and in the third case, it was delayed in upper lung field. This distribution was different from the result in the other chronic obstructive pulmonary disease (COPD). In most cases of COPD, /sup 133/Xe washout was prominently delayed in the lower lung field. Distribution of pulmonary perfusion in HAM were consistent with that of ventilation as in COPD.

  11. Effect of adenosine1-receptor blockade on renin release from rabbit isolated perfused juxtaglomerular apparatus

    DEFF Research Database (Denmark)

    Weihprecht, H; Lorenz, J N; Schnermann, J

    1990-01-01

    Adenosine has been proposed to act within the juxtaglomerular apparatus (JGA) as a mediator of the inhibition of renin secretion produced by a high NaCl concentration at the macula densa. To test this hypothesis, we studied the effects of the adenosine1 (A1)-receptor blocker 8-cyclopentyl-1......,3-dipropylxanthine (CPX) on renin release from single isolated rabbit JGAs with macula densa perfused. The A1-receptor agonist, N6-cyclohexyladenosine (CHA), applied in the bathing solution at 10(-7) M, was found to inhibit renin secretion, an effect that was completely blocked by adding CPX (10(-5) M) to the bath....... Applied to the lumen, 10(-5) M CPX produced a modest stimulation of renin secretion rates suppressed by a high NaCl concentration at the macula densa (P less than 0.05). The effect of changing luminal NaCl concentration on renin secretion rate was examined in the presence of CPX (10(-7) and 10(-5) M...

  12. The evaluation of the degree of impairment of pulmonary perfusion in lung cancer patients treated by radiotherapy by the quantification of nonuniform distribution of lung perfusion scintigraphy SPECT

    International Nuclear Information System (INIS)

    Mitomo, Osamu; Tsunoda, Takashi; Kuwabara, Hidemasa

    2004-01-01

    By means of quantifying the nonuniform distribution of pulmonary perfusion in Lung Perfusion Scintigraphy SPECT (single photon emission tomography), which is called ''SPECT'' for short, we evaluated the degree of functional impairment of pulmonary perfusion in non-operated lung cancer patients treated by the radiotherapy. Sixty-eight patients with non-operated lung cancer treated with radiotherapy, and who either received or did not receive chemotherapy, from February, 1996 to August, 2002, were examined using SPECT within 6 weeks prior to, or within 2 weeks following radiotherapy. This group was called ''irradiated lung cancer patients''. Twenty-six patients, who were called ''follow-up irradiated lung cancer patients'', were reexamined within four weeks after radiotherapy. On the other hand, 323 patients without lung cancer, who were subdivided into four groups; pulmonary, cardiac, cardio-pulmonary, and non-cardiopulmonary. The SPECT was examined in the supine position after infusing Tc-99m-MAA, 185 MBq in a bolus, mainly into an antecubital vein with the patient's arm elevated. From reconstructed SPECT images, the volume of lung as a whole calculated at 10% of thresholds was assumed to be the ''Baseline Lung Perfusion Volume'' (BPV), and the functional volume rates were calculated in 10% threshold widths from 10% to 100% of the threshold. Assuming the total absolute differences in functional volume rate between each subject and the control to be the distribution index of the lung as a whole (D index), we quantified the degree of nonuniform distribution of the lung as a whole in each subject. In the same way, the distribution index of the left or right lung respectively was calculated as D l or D r index assuming the volume of left or right lung were calculated at 10% of the threshold as left or right BPV and calculating the functional volume rates of each lung in 10% threshold widths from 10% to 100% of the threshold. The D index of irradiated lung cancer

  13. Structural and perfusion magnetic resonance imaging of the lung in cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Amaxopoulou, Christina; Gnannt, Ralph; Kellenberger, Christian J. [University Children' s Hospital Zuerich, Department of Diagnostic Imaging, Zuerich, CH (Switzerland); University Children' s Hospital Zuerich, Children' s Research Center, Zuerich (Switzerland); Higashigaito, Kai [University Hospital Zuerich, Institute of Diagnostic and Interventional Radiology, Zuerich (Switzerland); Jung, Andreas [University Children' s Hospital Zuerich, Children' s Research Center, Zuerich (Switzerland); University Children' s Hospital Zuerich, Division of Pneumology, Zuerich (Switzerland)

    2018-02-15

    Because of its absence of ionising radiation and possibility for obtaining functional information, MRI is promising for assessing lung disease in children who require repetitive imaging for long-term follow-up. To describe MRI findings in children with cystic fibrosis and evaluate semi-quantitative dynamic contrast-enhanced lung perfusion. We retrospectively compared lung MRI in 25 children and young adults with cystic fibrosis (median age 3.7 years) to 12 children (median age 2 years) imaged for other pathologies. MRI at 1.5 T included respiratory-gated sequences and contrast-enhanced lung perfusion imaging. We described and graded any morphologic change. Signal enhancement and time to peak values of perfusion abnormalities were compared to those of normally enhancing lung parenchyma. Frequent findings in patients with cystic fibrosis were bronchial wall thickening (24/25, 96%), areas of consolidation (22/25, 88%), enlarged lymph nodes (20/25, 80%), bronchiectasis (5/25, 20%) and mucus plugging (3/25, 12%). Compared to normally enhancing lung, perfusion defects (21/25, 84%), characterised by decreased enhancement, showed prolonged time to peak. Areas of consolidation showed increased enhancement. While time to peak of procedure-related atelectasis was not significantly different from that of normal lung, disease-related consolidation showed prolonged time to peak (P=0.01). Lung MRI demonstrates structural and perfusion abnormalities in children and young people with cystic fibrosis. Semi-quantitative assessment of dynamic contrast-enhanced perfusion imaging might allow differentiation between procedure-related atelectasis and disease-related consolidation. (orig.)

  14. Structural and perfusion magnetic resonance imaging of the lung in cystic fibrosis

    International Nuclear Information System (INIS)

    Amaxopoulou, Christina; Gnannt, Ralph; Kellenberger, Christian J.; Higashigaito, Kai; Jung, Andreas

    2018-01-01

    Because of its absence of ionising radiation and possibility for obtaining functional information, MRI is promising for assessing lung disease in children who require repetitive imaging for long-term follow-up. To describe MRI findings in children with cystic fibrosis and evaluate semi-quantitative dynamic contrast-enhanced lung perfusion. We retrospectively compared lung MRI in 25 children and young adults with cystic fibrosis (median age 3.7 years) to 12 children (median age 2 years) imaged for other pathologies. MRI at 1.5 T included respiratory-gated sequences and contrast-enhanced lung perfusion imaging. We described and graded any morphologic change. Signal enhancement and time to peak values of perfusion abnormalities were compared to those of normally enhancing lung parenchyma. Frequent findings in patients with cystic fibrosis were bronchial wall thickening (24/25, 96%), areas of consolidation (22/25, 88%), enlarged lymph nodes (20/25, 80%), bronchiectasis (5/25, 20%) and mucus plugging (3/25, 12%). Compared to normally enhancing lung, perfusion defects (21/25, 84%), characterised by decreased enhancement, showed prolonged time to peak. Areas of consolidation showed increased enhancement. While time to peak of procedure-related atelectasis was not significantly different from that of normal lung, disease-related consolidation showed prolonged time to peak (P=0.01). Lung MRI demonstrates structural and perfusion abnormalities in children and young people with cystic fibrosis. Semi-quantitative assessment of dynamic contrast-enhanced perfusion imaging might allow differentiation between procedure-related atelectasis and disease-related consolidation. (orig.)

  15. The Rabbit as a Model for Studying Lung Disease and Stem Cell Therapy

    Directory of Open Access Journals (Sweden)

    Nurfatin Asyikhin Kamaruzaman

    2013-01-01

    Full Text Available No single animal model can reproduce all of the human features of both acute and chronic lung diseases. However, the rabbit is a reliable model and clinically relevant facsimile of human disease. The similarities between rabbits and humans in terms of airway anatomy and responses to inflammatory mediators highlight the value of this species in the investigation of lung disease pathophysiology and in the development of therapeutic agents. The inflammatory responses shown by the rabbit model, especially in the case of asthma, are comparable with those that occur in humans. The allergic rabbit model has been used extensively in drug screening tests, and this model and humans appear to be sensitive to similar drugs. In addition, recent studies have shown that the rabbit serves as a good platform for cell delivery for the purpose of stem-cell-based therapy.

  16. Manipulations of core temperatures in ischemia-reperfusion lung injury in rabbits.

    Science.gov (United States)

    Chang, Hung; Huang, Kun-Lun; Li, Min-Hui; Hsu, Ching-Wang; Tsai, Shih-Hung; Chu, Shi-Jye

    2008-01-01

    The present study was designed to determine the effect of various core temperatures on acute lung injury induced by ischemia-reperfusion (I/R) in our isolated rabbit lung model. Typical acute lung injury was successfully induced by 30 min of ischemia followed by 90 min of reperfusion observation. The I/R elicited a significant increase in pulmonary arterial pressure, microvascular permeability (measured by using the capillary filtration coefficient, Kfc), Delta Kfc ratio, lung weight gain and the protein concentration of the bronchoalveolar lavage fluid. Mild hypothermia significantly attenuated acute lung injury induced by I/R, all parameters having decreased significantly (p<0.05); conversely, mild hyperthermia did not further exacerbate acute lung injury. These experimental data suggest that mild hypothermia significantly ameliorated acute lung injury induced by ischemia-reperfusion in rabbits.

  17. Clinical evaluation of lung rest/stress perfusion scintigraphy in patients with severe emphysema

    International Nuclear Information System (INIS)

    Hadjikostova, Hr.

    1998-01-01

    Volume lung reduction surgery (LVRS) improves lung function and physical tolerance for selected patients with severe pulmonary emphysema by making conditions for developing of the vital parenchyma so far compressed by the emphysema blisters. The aim of this study was to establish the comparative functional information obtained from REST/STRESS lung perfusion tomoscintigraphies for identification of non functional lung tissue. Eleven patients (8 males and 3 females at age 41-60) were examined by two lung perfusions SPECT scintigraphies after intravenous application of 222 MBq 99m Tc-MAA: 1. after 30 min. lying rest and 2. 48 hours later after 6 min. walk test. Comparing the two scintigraphies the following changes in perfusion performance have been established at STRESS examination: increased at six patients (significant at three and slight also at three) and decreased at two. There was no difference between REST and STRESS examinations at 3 patients. Comparative REST/STRESS lung perfusion scintigraphy is important method for screening severe pulmonary patients for LVRS. (author)

  18. Evaluation of Tl-201 lung uptake and impairment of pulmonary perfusion on scintigraphies in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Tanaka, Masao; Koizumi, Tomonori; Kubo, Keishi

    2000-01-01

    Tl-201 lung uptake in 74 patients (85 lesions) and pulmonary perfusion in 105 patients were studied to evaluate clinical usefulness of Tl-201 lung uptake and perfusion lung scintigraphy in pulmonary tuberculosis, using a scintillation camera with a mini-computer system. As indices of Tl-201 lung uptake, lung (lesion) to upper mediastinum uptake ratio (L/M) and visual grading were used. L/M in pulmonary tuberculosis was 1.96±0.66, which was significantly larger than 1.04±0.24 in healthy controls and lower than that in heart diseases with left heart failure and idiopathic interstitial pneumonia, and showed no significant differences with that in acute pneumonia, pyothorax, primary lung cancer and malignant mediastinal tumor. L/M in pulmonary tuberculosis did not correlate with CRP, erythrocyte sedimentation rate, Gaffky number of sputum and body temperature. It correlated with the type of pulmonary tuberculosis according to the Gakken Classification reflecting the disease activity. It was larger in the exudative type, caseo-infiltrative one, disseminated one, one with cavity in infiltrative lesion than the fibro-caseous one. On perfusion lung scintigram, impairment of pulmonary perfusion larger than area of the entire unilateral lung was observed in 68 cases (64.8%). Area of hypoperfused lung field, which correlated with % vital capacity (r=0.60, p=0.0002) and PaO 2 (r=0.39,p=0.0024), was significantly larger in patients with silicosis and those with bilateral pleural involvements such as pleural callosity than in those with type III according to the Gakkai Classification. Most of the patients showed decreased pulmonary perfusion and Tl-201 accumulation of which grade reflects the disease activity in active tuberculous lesion. Patients with miliary tuberculosis and those with silicotuberculosis showed diffuse Tl-201 accumulation in the both lungs. Tl-201 lung scintigraphy seems to be useful for visualizing active tuberculous lesions, particularly the ones that

  19. Distribution of endotracheally instilled surfactant protein SP-C in lung-lavaged rabbits.

    NARCIS (Netherlands)

    Bambang Oetomo, Sidarto; de Leij, Louis; Curstedt, T; ter Haar, J G; Schoots, Coenraad; Wildevuur, Charles; Okken, Albert

    In lung-lavaged surfactant-deficient rabbits (n = 6) requiring artificial ventilation, porcine surfactant was instilled endotracheally. This resulted in improvement of lung function so that the animals could be weaned off artificial ventilation. The animals were killed 4 1/2 h after surfactant

  20. Barotrauma and microvascular injury in lungs of nonadult rabbits: effect of ventilation pattern.

    Science.gov (United States)

    Peevy, K J; Hernandez, L A; Moise, A A; Parker, J C

    1990-06-01

    To study the pulmonary microvascular injury produced by ventilation barotrauma, the isolated perfused lungs of 4 to 6-wk-old New Zealand white rabbits were ventilated by one of the following methods: peak inspiratory pressure (PIP) 23 cm H2O, gas flow rate 1.1 L/min (group 1); PIP 27 cm H2O, gas flow rate 6.9 L/min (group 2); PIP 50 cm H2O, gas flow rate 1.9 L/min (group 3); or PIP 53 cm H2O, gas flow rate 8.3 L/min (group 4). Microvascular permeability was assessed using the capillary filtration coefficient (Kfc) before and 5, 30, and 60 min after a 15-min period of ventilation. Baseline Kfc was not significantly different between groups. A significant increase over the baseline Kfc was noted at 60 min in group 2 and in all postventilation Kfc values in groups 3 and 4 (p less than .05). Group 1 Kfc values did not change significantly after ventilation. At all post-ventilation times, values for Kfc were significantly greater in groups 3 and 4 than in group 1 (p less than .05). Group 4 Kfc values were significantly greater than those in group 2 at 5 and 30 min postventilation. These data indicate that high PIP, and to a lesser extent, high gas flow rates cause microvascular injury in the compliant nonadult lung and suggest that the combination of high PIP and high gas flow rates are the most threatening to microvascular integrity.

  1. Abolished ventilation and perfusion of lung caused by blood clot in the left main bronchus

    DEFF Research Database (Denmark)

    Afzelius, P; Bergmann, A; Henriksen, J H

    2015-01-01

    /Q) scintigraphy with single-photon emission CT (SPECT)/CT. V/Q SPECT/CT demonstrated abolished ventilation due to obstruction of the left main bronchus and markedly reduced perfusion of the entire left lung, a condition that was completely reversed after removal of a blood clot. We present the first pictorially......It is generally assumed that the lungs possess arterial autoregulation associated with bronchial obstruction. A patient with pneumonia and congestive heart failure unexpectedly developed frequent haemoptysis. High-resolution CT and diagnostic CT were performed as well as ventilation/perfusion (V...

  2. Estimation of pulmonary hypertension of congenital heart diseases in children by lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Zheng Jinghao; Zhang Shantong; Zeng Jiye; Jia Hongli; Ji Zhiying; Chen Siyi

    1993-01-01

    The authors report that changes in the distribution of pulmonary perfusion caused by gravitation effect, namely, changes in the total count ratios of the right against the left lung between right and left lateral decubitus positions (rt/lt) could estimate pulmonary hypertension using lung perfusion scintigraphy with 99m Tc-labelled macroaggregated albumin. The results showed: rt/lt was inversely related to mean pulmonary arterial pressure. It is concluded that the method is simple, safe, reproducible, unaffected by cardiac structural abnormality and valuable as a noninvasive approach for the estimation of pulmonary hypertension

  3. Studies on pulmonary ventilation-perfusion scintigraphy with Xe-133 in primary lung cancer, 1

    International Nuclear Information System (INIS)

    Oshibuchi, Masao

    1984-01-01

    Regional lung ventilation-perfusion scintigraphy by xenon gas was performed on 14 normal cases (normal group) and 86 cases of primary lung cancer (lung cancer group). The patients were measured in a sitting position using a scintillation camera. In normal group, the value of V, Q was higher in the lower lung field than in the upper lung field, the value of MTT was rather delayed in the upper lung field than in the lower lung field, proving to that lung clearance was better in the lower lung field than in the upper lung field. In lung cancer group, VQ match (pattern I, II) was 61 cases (71%) and VQ mismatch (pattern III, IV) was 25 cases (29%). The pattern II (VQ matched defect) accounted for 63% in lung cancer group. In this pattern, the region of disorder of V and Q was corresponded respectively, but disorder grade was not always accorded. The pattern III (normal V and disordered Q) was mainly seen in AH group (hilar type) and D group (lymph node swelling type). The V/Q in lung cancer group was widely distributed to the range of 0 to 5.8. The value of MTT was rather delayed in all cases of lung cancer group than in the normal group, because delayed MTT in focal lesion was markedly affected to whole lung. (author)

  4. Accuracy and feasibility of dynamic contrast-enhanced 3D MR imaging in the assessment of lung perfusion: comparison with Tc-99 MAA perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yilmaz, E.; Akkoclu, A.; Degirmenci, B.; Cooper, R.A.; Sengun, B.; Gulcu, A.; Osma, E.; Ucan, E.S.

    2005-01-01

    AIM: The aim of this study was to correlate findings of perfusion magnetic resonance imaging (MRI) and perfusion scintigraphy in cases where there was a suspicion of abnormal pulmonary vasculature, and to evaluate the usefulness of MRI in the detection of perfusion deficits of the lung. METHODS: In all, 17 patients with suspected abnormality of the pulmonary vasculature underwent dynamic contrast-enhanced MRI. T1-weighted 3D fast-field echo pulse sequences were obtained (TR/TE 3.3/1.58 ms; flip angle 30 deg ; slice thickness 12 to 15 mm). The dynamic study was acquired in the coronal plane following administration of 0.1 mmol/kg gadopentetate dimeglumine. A total of 8 to 10 sections repeated 20 to 25 times at intervals of 1 s were performed. Perfusion lung scintigraphy was carried out a maximum of 48 h before the MR examination in all cases. Two radiologists, who were blinded to the clinical data and results of other imaging methods, reviewed all coronal sections. MR perfusion images were independently assessed in terms of segmental or lobar perfusion defects in the 85 lobes of the 17 individuals, and the findings were compared with the results of scintigraphy. RESULTS: Of the 17 patients, 8 were found to have pulmonary emboli, 2 chronic obstructive pulmonary disease with emphysema, 2 bullous emphysema, 2 Takayasu arteritis and 1 had a hypoplastic pulmonary artery. Pulmonary perfusion was completely normal in 2 cases. In 35 lobes, perfusion defects were detected using both methods, in 4 with MR alone and in 9 only with scintigraphy. There was good agreement between MRI and scintigraphy findings (kappa=0.695). CONCLUSION: Pulmonary perfusion MRI is a new alternative to scintigraphy in the evaluation of pulmonary perfusion for various lung disorders. In addition, this technique allows measurement and quantification of pulmonary perfusion abnormalities

  5. Unilateral absence of lung perfusion resulting from endarteritis of the pulmonary artery

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Turini, T.L.

    This case shows endarteritis of left pulmonary artery in the angiographic study with absent perfusion of the left lung in the MAA 131 I scintigraphy. Considerations are made conderning the presumable diagnosis of infection by 'toxocara canis' larval form. The literature review don't point out a similar case. (author) [pt

  6. Framework for radiation pneumonitis risk stratification based on anatomic and perfused lung dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Dhami, Gurleen; Zeng, Jing; Patel, Shilpen A.; Rengan, Ramesh [University of Washington School of Medicine, Department of Radiation Oncology, Seattle, WA (United States); Vesselle, Hubert J.; Kinahan, Paul E.; Miyaoka, Robert S. [University of Washington School of Medicine, Department of Radiology, Seattle, WA (United States); Bowen, Stephen R. [University of Washington School of Medicine, Department of Radiation Oncology, Seattle, WA (United States); University of Washington School of Medicine, Department of Radiology, Seattle, WA (United States)

    2017-05-15

    To design and apply a framework for predicting symptomatic radiation pneumonitis in patients undergoing thoracic radiation, using both pretreatment anatomic and perfused lung dose-volume parameters. Radiation treatment planning CT scans were coregistered with pretreatment [{sup 99m}Tc]MAA perfusion SPECT/CT scans of 20 patients who underwent definitive thoracic radiation. Clinical radiation pneumonitis was defined as grade ≥ 2 (CTCAE v4 grading system). Anatomic lung dose-volume parameters were collected from the treatment planning scans. Perfusion dose-volume parameters were calculated from pretreatment SPECT/CT scans. Equivalent doses in 2 Gy per fraction were calculated in the lung to account for differences in treatment regimens and spatial variations in lung dose (EQD2{sub lung}). Anatomic lung dosimetric parameters (MLD) and functional lung dosimetric parameters (pMLD{sub 70%}) were identified as candidate predictors of grade ≥ 2 radiation pneumonitis (AUC > 0.93, p < 0.01). Pairing of an anatomic and functional dosimetric parameter (e.g., MLD and pMLD{sub 70%}) may further improve prediction accuracy. Not all individuals with high anatomic lung dose (MLD > 13.6 GyEQD2{sub lung}, 19.3 Gy for patients receiving 60 Gy in 30 fractions) developed radiation pneumonitis, but all individuals who also had high mean dose to perfused lung (pMLD{sub 70%} > 13.3 GyEQD2) developed radiation pneumonitis. The preliminary application of this framework revealed differences between anatomic and perfused lung dosimetry in this limited patient cohort. The addition of perfused lung parameters may help risk stratify patients for radiation pneumonitis, especially in treatment plans with high anatomic mean lung dose. Further investigations are warranted. (orig.) [German] Erstellung und Anwendung eines Rahmenwerks zur Vorhersage symptomatischer Strahlenpneumonitis bei Patienten mit einer Thorax-Bestrahlung anhand anatomischer und perfundierter Lungendosis-Volumen-Parameter in der

  7. Ex vivo lung perfusion to improve donor lung function and increase the number of organs available for transplantation.

    Science.gov (United States)

    Valenza, Franco; Rosso, Lorenzo; Coppola, Silvia; Froio, Sara; Palleschi, Alessandro; Tosi, Davide; Mendogni, Paolo; Salice, Valentina; Ruggeri, Giulia M; Fumagalli, Jacopo; Villa, Alessandro; Nosotti, Mario; Santambrogio, Luigi; Gattinoni, Luciano

    2014-06-01

    This paper describes the initial clinical experience of ex vivo lung perfusion (EVLP) at the Fondazione Ca' Granda in Milan between January 2011 and May 2013. EVLP was considered if donor PaO2 /FiO2 was below 300 mmHg or if lung function was doubtful. Donors with massive lung contusion, aspiration, purulent secretions, pneumonia, or sepsis were excluded. EVLP was run with a low-flow, open atrium and low hematocrit technique. Thirty-five lung transplants from brain death donors were performed, seven of which after EVLP. EVLP donors were older (54 ± 9 years vs. 40 ± 15 years, EVLP versus Standard, P donor organs and resulted in successful transplants with lungs that would have otherwise been rejected (ClinicalTrials.gov number: NCT01967953). © 2014 The Authors. Transplant International published by John Wiley & Sons Ltd on behalf of Steunstichting ESOT.

  8. Respiratory lung motion analysis using a nonlinear motion correction technique for respiratory-gated lung perfusion SPECT images

    International Nuclear Information System (INIS)

    Ue, Hidenori; Haneishi, Hideaki; Iwanaga, Hideyuki; Suga, Kazuyoshi

    2007-01-01

    This study evaluated the respiratory motion of lungs using a nonlinear motion correction technique for respiratory-gated single photon emission computed tomography (SPECT) images. The motion correction technique corrects the respiratory motion of the lungs nonlinearly between two-phase images obtained by respiratory-gated SPECT. The displacement vectors resulting from respiration can be computed at every location of the lungs. Respiratory lung motion analysis is carried out by calculating the mean value of the body axis component of the displacement vector in each of the 12 small regions into which the lungs were divided. In order to enable inter-patient comparison, the 12 mean values were normalized by the length of the lung region along the direction of the body axis. This method was applied to 25 Technetium (Tc)-99m-macroaggregated albumin (MAA) perfusion SPECT images, and motion analysis results were compared with the diagnostic results. It was confirmed that the respiratory lung motion reflects the ventilation function. A statistically significant difference in the amount of the respiratory lung motion was observed between the obstructive pulmonary diseases and other conditions, based on an unpaired Student's t test (P<0.0001). A difference in the motion between normal lungs and lungs with a ventilation obstruction was detected by the proposed method. This method is effective for evaluating obstructive pulmonary diseases such as pulmonary emphysema and diffuse panbronchiolitis. (author)

  9. Comparative study of rabbit VX2 hepatic implantation tumor and normal liver tissue on magnetic resonance perfusion weighted imaging

    International Nuclear Information System (INIS)

    Jiao Zimei; Wang Xizhen; Wang Bin; Liu Feng; Li Haiqing; Sun Yequan; Dong Peng

    2012-01-01

    Objective: To investigate the value of magnetic resonance (MR) perfusion weighted imaging (PWI) in evaluating the blood perfusion of tumor by analyzing the features and indexes of PWI on rabbit VX2 hepatic implantation tumor and normal liver tissue. Methods: Twenty-four New Zealand White rabbits with VX2 carcinoma were established under direct surgical vision embedding tumor tissue. MR examination was performed at 21 days after the tumor implantation. The signal intensity -time curve of hepatic tumor and normal liver tissue were obtained. Mean time to enhance (MTE), negative enhancement integral (NEI), time to minimum (TM), maximum slope of decrease (MSD) and maximum slope of increase (MSI) were measured. Results: MTE, NEI, TM, MSD, and MSI of the normal liver tissue were 208.341±2.226 ms, 78.334±8.152, 24.059±1.927 ms, 38.221±2.443, and 15.389±2.526, respectively. MTE, NEI, TM, MSD, and MSI of the tumor tissue were 175.437±4.182 ms, 123.203±19.455, 17.061±1.834 ms, 125.740±4.842, and 67.832±2.882, respectively. The MTE and TM of tumor were shorter than those of normal hepatic tissue (P<0.05). NEI, MSD, and MSI of tumor were higher than those of normal hepatic tissue (P<0.05). Conclusion: PWI can distinguish the normal liver tissue from the tumor tissue, which is helpful in evaluating blood perfusion of different hepatic tissues. (authors)

  10. Lung morphometry, collagen and elastin content: changes after hyperoxic exposure in preterm rabbits

    Directory of Open Access Journals (Sweden)

    Renata Suman Mascaretti

    2009-11-01

    Full Text Available INTRODUCTION: Elastic and collagen fiber deposition increases throughout normal lung development, and this fiber network significantly changes when development of the lung is disturbed. In preterm rats and lambs, prolonged hyperoxic exposure is associated with impaired alveolization and causes significant changes in the deposition and structure of elastic fibers. OBJECTIVES: To evaluate the effects of hyperoxic exposure on elastic and collagen fiber deposition in the lung interstitial matrix and in alveolarization in preterm rabbits. METHODS: After c-section, 28-day preterm New-Zealand-White rabbits were randomized into 2 study groups, according to the oxygen exposure, namely: Room air (oxygen = 21% or Oxygen (oxygen > 95%. The animals were killed on day 11 and their lungs were analyzed for the alveolar size (Lm, the internal surface area (ISA, the alveoli number, and the density and distribution of collagen and elastic fibers. RESULTS: An increase in the Lm and a decrease in the alveoli number were observed among rabbits that were exposed to hyperoxia with no differences regarding the ISA. No difference in the density of elastic fibers was observed after oxygen exposure, however there were fewer collagen fibers and an evident disorganization of fiber deposition. DISCUSSION: This model reproduces anatomo-pathological injuries representing the arrest of normal alveolar development and lung architecture disorganization by just a prolonged exposition to oxygen. CONCLUSIONS: In the preterm rabbit, prolonged oxygen exposure impaired alveolization and also lowered the proportion of collagen fibers, with an evident fiber network disorganization.

  11. Acute cigarette smoke exposure causes lung injury in rabbits treated with ibuprofen

    Energy Technology Data Exchange (ETDEWEB)

    Witten, M.L.; Lemen, R.J.; Quan, S.F.; Sobonya, R.E.; Magarelli, J.L.; Bruck, D.C.

    1987-01-01

    We studied lung clearance of aerosolized technetium-labeled diethylenetriamine pentaacetic acid (/sup 99m/TcDTPA), plasma concentrations of 6-keto-PGF1 alpha and thromboxane B2, and pulmonary edema as indices of lung injury in rabbits exposed to cigarette smoke (CSE). Forty-six rabbits were randomly assigned to 4 groups: control sham smoke exposure (SS, N = 9), sham smoke exposure ibuprofen-pretreated (SS-I, N = 10), CSE (N = 9), sham smoke exposure ibuprofen-pretreated (SS-I, N = 10), CSE (N = 9), and CSE ibuprofen-pretreated (CSE-I, N = 19). Ibuprofen (cyclooxygenase eicosanoid inhibitor) was administered as a single daily intramuscular injection (25 mg/kg) for 7 days before the experiment. Cigarette or sham smoke was delivered by syringe in a series of 5, 10, 20, and 30 tidal volume breaths with a 15-min counting period between each subset of breaths to determine /sup 99m/TcDTPA biological half-life (T1/2). In the ibuprofen pretreated group, CSE caused significant decreases in /sup 99m/TcDTPA T1/2 and dynamic lung compliance. Furthermore, these changes in lung function were accompanied by severe injury to type I alveolar cell epithelium, pulmonary edema, and frequently death of the rabbits. These findings suggest that inhibition of the cyclooxygenase pathway before CSE exacerbates lung injury in rabbits.

  12. Acute cigarette smoke exposure causes lung injury in rabbits treated with ibuprofen

    International Nuclear Information System (INIS)

    Witten, M.L.; Lemen, R.J.; Quan, S.F.; Sobonya, R.E.; Magarelli, J.L.; Bruck, D.C.

    1987-01-01

    We studied lung clearance of aerosolized technetium-labeled diethylenetriamine pentaacetic acid (/sup 99m/TcDTPA), plasma concentrations of 6-keto-PGF1 alpha and thromboxane B2, and pulmonary edema as indices of lung injury in rabbits exposed to cigarette smoke (CSE). Forty-six rabbits were randomly assigned to 4 groups: control sham smoke exposure (SS, N = 9), sham smoke exposure ibuprofen-pretreated (SS-I, N = 10), CSE (N = 9), sham smoke exposure ibuprofen-pretreated (SS-I, N = 10), CSE (N = 9), and CSE ibuprofen-pretreated (CSE-I, N = 19). Ibuprofen (cyclooxygenase eicosanoid inhibitor) was administered as a single daily intramuscular injection (25 mg/kg) for 7 days before the experiment. Cigarette or sham smoke was delivered by syringe in a series of 5, 10, 20, and 30 tidal volume breaths with a 15-min counting period between each subset of breaths to determine /sup 99m/TcDTPA biological half-life (T1/2). In the ibuprofen pretreated group, CSE caused significant decreases in /sup 99m/TcDTPA T1/2 and dynamic lung compliance. Furthermore, these changes in lung function were accompanied by severe injury to type I alveolar cell epithelium, pulmonary edema, and frequently death of the rabbits. These findings suggest that inhibition of the cyclooxygenase pathway before CSE exacerbates lung injury in rabbits

  13. Absolute concentration determination of phosphorus metabolites in the Langendorff-perfused rabbit heart by phosphorus-31 nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Gard, J.K.

    1984-01-01

    The concentrations of mobile high energy phosphorus metabolites and intracellular pH of Langendorff-perfused rabbit heart have been determined under control and reduced flow conditions. Absolute concentration determination was accomplished by Lorentzian lineshape analysis after development of hexachlorocyclotriphosphazene as an external intensity standard. Hearts were demonstrated to be biochemically and physiologically competent during control perfusion periods and compromised during reduced flow conditions by independent hemodynamic and metabolic measurements coincident with the NMR experiment. Reduction in perfusate flow from 20 mL/min to 5.0 mL/min (25% flow) or 2.5 mL/min (12.5% flow) demonstrated a fall in phosphocreatine and adenosine triphosphate concentrations, a rise in cytosolic inorganic phosphate concentrations, and drops in pH. Subsequent recovery upon reflow was observed. The derived values for the free concentration of ADP were very close to the reported values of the Michaelis constant for respiratory stimulation, implicating a regulatory role for this molecule in cellular respiration. Strong evidence that the creating kinase reaction was in equilibrium in the 25% flow study was seen. The NMR observable correlated closely with myocardial performance and biochemical indices of metabolic function, and supported the use of phosphocreatine as an indicator of current metabolic integrity

  14. Evaluation of {sup 99m}Tc(CO){sub 5}I as a potential lung perfusion agent

    Energy Technology Data Exchange (ETDEWEB)

    Miroslavov, Alexander E.; Gorshkov, Nikolay I.; Lumpov, Alexander L. [Division of Radiochemical Research, Khlopin Radium Institute, 2nd Murinskii pr. 28, 194021, St Petersburg (Russian Federation); Yalfimov, Anatoly N. [Nuclear Medicine Department, Central Research Institute of Roentgenology and Radiology, Leningradskaya str. 70/4, 197000, St Petersburg (Russian Federation); Suglobov, Dmitrii N. [Division of Radiochemical Research, Khlopin Radium Institute, 2nd Murinskii pr. 28, 194021, St Petersburg (Russian Federation); Ellis, Beverley L. [Department of Nuclear Medicine, Manchester Royal Infirmary, M13 9WL Manchester (United Kingdom)], E-mail: bev.ellis@manchester.ac.uk; Braddock, Rattana; Smith, Anne-Marie [Imaging Science and Biomedical Engineering, School of Cancer and Imaging Science, Stopford Building, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom); Prescott, Mary C.; Lawson, Richard S. [Department of Nuclear Medicine, Manchester Royal Infirmary, M13 9WL Manchester (United Kingdom); Sharma, Harbans L. [Imaging Science and Biomedical Engineering, School of Cancer and Imaging Science, Stopford Building, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom)

    2009-01-15

    Introduction: The use of {sup 99m}Tc-macroggregated albumin for lung perfusion imaging is well established in nuclear medicine. However, there have been safety concerns over the use of blood-derived products because of potential contamination by infective agents, for example, Variant Creutzfeldt Jakob Disease. Preliminary work has indicated that Tc(CO){sub 5}I is primarily taken up in the lungs following intravenous administration. The aim of this study was to evaluate the biodistribution and pharmacokinetics of {sup 99m}Tc(CO){sub 5}I and its potential as a lung perfusion agent. Methods: {sup 99m}Tc(CO){sub 5}I was synthesized by carbonylation of {sup 99m}TcO{sub 4-} at 160 atm of CO at 170 deg. C in the presence of HI for 40 min. Radiochemical purity was determined by HPLC using {sup 99}Tc(CO){sub 5}I as a reference. {sup 99m}Tc(CO){sub 5}I was administered by ear-vein injection to three chinchilla rabbits, and dynamic images were acquired using a gamma camera (Siemens E-cam) over 20 min. Imaging studies were also performed with {sup 99m}Tc-labeled macroaggregated albumin ({sup 99m}Tc-MAA) and {sup 99m}TcO{sub 4-} for comparison. {sup 99m}Tc(CO){sub 5}I was administered intravenously to Sprague-Dawley rats, and tissue distribution studies were obtained at 15 min and 1 h postinjection. Comparative studies were performed using {sup 99m}Tc-MAA. Results: Radiochemical purity, assessed by HPLC, was 98%. The retention time was similar to that of {sup 99}Tc(CO){sub 5}I. The dynamic images showed that 70% of {sup 99m}Tc(CO){sub 5}I appeared promptly in the lungs and remained constant for at least 20 min. In contrast, {sup 99m}TcO{sub 4-} rapidly washed out of the lungs after administration. As expected {sup 99m}Tc-MAA showed 90% lung accumulation. The percentage of injected dose per gram of organ {+-}S.D. at 1 h for {sup 99m}Tc(CO){sub 5}I was as follows: blood, 0.22{+-}0.02; lung, 12.8{+-}2.87; liver, 0.8{+-}0.15; heart, 0.15{+-}0.01; kidney, 0.47{+-}0.08. The

  15. Radiographic and radionuclide lung perfusion imaging in healthy calves and calves naturally infected with bovine respiratory syncytial virus

    International Nuclear Information System (INIS)

    Verhoeff, J.; Brom, W.E. van den; Ingh, T.S.G.A.M. van den

    1992-01-01

    Nine calves between three and 18 weeks old with serologically confirmed natural bovine respiratory syncytial virus infection were examined clinically, radiographically and by radionuclide lung perfusion imaging. The results were compared with those from seven healthy calves. The diseased calves were euthanased and examined pathologically, virologically and bacteriologically. The clinical signs indicated that the disease was in an acute stage. Radiography of the diseased animals revealed cysts, corresponding morphologically with bullous emphysema, and infiltrations roughly corresponding in distribution with atelectatic and, or, pneumonic areas. Radionuclide lung perfusion imaging revealed no perfusion shifts between the left and right lungs and a normal perfusion pattern in five of the nine diseased calves. The abnormalities in the perfusion patterns of three calves were probably caused by anatomical disorders such as cysts and pleural adhesions, but no cause of the abnormality could be found in one calf. These findings suggest that in calves infected with bovine respiratory syncytial virus, the normal perfusion pattern is maintained until anatomical disorders occur. The pathological examination and radiography revealed that the cranioventral lung fields were particularly poorly ventilated. This finding and the normal perfusion pattern indicate that these parts of the lungs are probably the sites where shuntings and perfusion-ventilation mismatchings occur

  16. Ex vivo lung perfusion with adenosine A2A receptor agonist allows prolonged cold preservation of lungs donated after cardiac death.

    Science.gov (United States)

    Wagner, Cynthia E; Pope, Nicolas H; Charles, Eric J; Huerter, Mary E; Sharma, Ashish K; Salmon, Morgan D; Carter, Benjamin T; Stoler, Mark H; Lau, Christine L; Laubach, Victor E; Kron, Irving L

    2016-02-01

    Ex vivo lung perfusion has been successful in the assessment of marginal donor lungs, including donation after cardiac death (DCD) donor lungs. Ex vivo lung perfusion also represents a unique platform for targeted drug delivery. We sought to determine whether ischemia-reperfusion injury would be decreased after transplantation of DCD donor lungs subjected to prolonged cold preservation and treated with an adenosine A2A receptor agonist during ex vivo lung perfusion. Porcine DCD donor lungs were preserved at 4°C for 12 hours and underwent ex vivo lung perfusion for 4 hours. Left lungs were then transplanted and reperfused for 4 hours. Three groups (n = 4/group) were randomized according to treatment with the adenosine A2A receptor agonist ATL-1223 or the dimethyl sulfoxide vehicle: Infusion of dimethyl sulfoxide during ex vivo lung perfusion and reperfusion (DMSO), infusion of ATL-1223 during ex vivo lung perfusion and dimethyl sulfoxide during reperfusion (ATL-E), and infusion of ATL-1223 during ex vivo lung perfusion and reperfusion (ATL-E/R). Final Pao2/Fio2 ratios (arterial oxygen partial pressure/fraction of inspired oxygen) were determined from samples obtained from the left superior and inferior pulmonary veins. Final Pao2/Fio2 ratios in the ATL-E/R group (430.1 ± 26.4 mm Hg) were similar to final Pao2/Fio2 ratios in the ATL-E group (413.6 ± 18.8 mm Hg), but both treated groups had significantly higher final Pao2/Fio2 ratios compared with the dimethyl sulfoxide group (84.8 ± 17.7 mm Hg). Low oxygenation gradients during ex vivo lung perfusion did not preclude superior oxygenation capacity during reperfusion. After prolonged cold preservation, treatment of DCD donor lungs with an adenosine A2A receptor agonist during ex vivo lung perfusion enabled Pao2/Fio2 ratios greater than 400 mm Hg after transplantation in a preclinical porcine model. Pulmonary function during ex vivo lung perfusion was not predictive of outcomes after transplantation. Copyright

  17. Lung perfusion scintigraphy in the diagnosis of peripheral pulmonary stenosis in patients after repair of Fallot tetralogy

    International Nuclear Information System (INIS)

    Sabiniewicz, R.; Chojnicki, M.; Alszewicz-Baranowska, J.; Erecinski, J.; Romanowicz, G.; Lass, P.; Bandurski, T.

    2002-01-01

    The frequency of peripheral pulmonary artery stenosis in patients after surgical repair of tetralogy of Fallot (TOF) ranges from 20 to 40%. This can be either primary or secondary to the surgical intervention. The influence of resulting lung perfusion alterations on the life quality of patients is difficult to predict. The aim of this study was to compare the utility of the diagnostic procedures in this group of patients, with particular focus on lung perfusion scintigraphy. This study comprised 104 patients who underwent repair of TOF at ages from 5 months to 25 years. The patients have been followed up for from 4.2 to 25 years. On the basis of chest X-ray peripheral pulmonary artery stenosis was suspected in 11 patients, in 12 on the basis of echocardiography examination. Lung perfusion scintigraphy has been performed on 87 patients. The disturbances in lung perfusion (mostly in the left lung) were show by means of lung perfusion scintigraphy in 43 (49%) of patients. In 27 of them heart catheterisation has been performed. Angiography revealed stenosis of the lung artery branch in 15/43 (34.9%) patients with abnormal perfusion lung scan and in 4/44 (9%) in patients with normal perfusion lung scan. Intervention procedures were carried out on 10 patients. Lung perfusion scintigraphy may prove a valuable, non-invasive screening tool in the assessment of patients after TOF repair, although both false-negative and false positive results may happen. Therefore, it should play an auxiliary role together with other diagnostic modalities. (author)

  18. Lung perfusion and emphysema distribution affect the outcome of endobronchial valve therapy

    Directory of Open Access Journals (Sweden)

    Thomsen C

    2016-06-01

    Full Text Available Christian Thomsen,1 Dorothea Theilig,2 Dominik Herzog,1 Alexander Poellinger,2 Felix Doellinger,2 Nils Schreiter,3 Vera Schreiter,2 Dirk Schürmann,1 Bettina Temmesfeld-Wollbrueck,1 Stefan Hippenstiel,1 Norbert Suttorp,1 Ralf-Harto Hubner1 1Department of Internal Medicine/Infectious Diseases and Respiratory Medicine, 2Institute of Radiology, 3Institute of Nuclear Medicine, Charité – Universitätsmedizin Berlin, Berlin, Germany Abstract: The exclusion of collateral ventilation (CV and other factors affect the clinical success of endoscopic lung volume reduction (ELVR. However, despite its benefits, the outcome of ELVR remains difficult to predict. We investigated whether clinical success could be predicted by emphysema distribution assessed by computed tomography scan and baseline perfusion assessed by perfusion scintigraphy. Data from 57 patients with no CV in the target lobe (TL were retrospectively analyzed after ELVR with valves. Pulmonary function tests (PFT, St George’s Respiratory Questionnaire (SGRQ, and 6-minute walk tests (6MWT were performed on patients at baseline. The sample was grouped into high and low levels at the median of TL perfusion, ipsilateral nontarget lobe (INL perfusion, and heterogeneity index (HI. These groups were analyzed for association with changes in outcome parameters from baseline to 3 months follow-up. Compared to baseline, patients showed significant improvements in PFT, SGRQ, and 6MWT (all P≤0.001. TL perfusion was not associated with changes in the outcome. High INL perfusion was significantly associated with increases in 6MWT (P=0.014, and high HI was associated with increases in forced expiratory volume in 1 second (FEV1, (P=0.012. Likewise, there were significant correlations for INL perfusion and improvement of 6MWT (r=0.35, P=0.03 and for HI and improvement in FEV1 (r=0.45, P=0.001. This study reveals new attributes that associate with positive outcomes for patient selection prior to ELVR

  19. Role of perfusion SPECT in prediction and measurement of pulmonary complications after radiotherapy for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Farr, Katherina P.; Khalil, Azza A.; Grau, Cai [Aarhus University Hospital, Department of Oncology, Aarhus C (Denmark); Kramer, Stine; Morsing, Anni [Aarhus University Hospital, Department of Nuclear Medicine and PET Centre, Aarhus C (Denmark)

    2015-07-15

    The purpose of the study was to evaluate the ability of baseline perfusion defect score (DS) on SPECT to predict the development of severe symptomatic radiation pneumonitis (RP) and to evaluate changes in perfusion on SPECT as a method of lung perfusion function assessment after curative radiotherapy (RT) for non-small-cell lung cancer (NSCLC). Patients with NSCLC undergoing curative RT were included prospectively. Perfusion SPECT/CT and global pulmonary function tests (PFT) were performed before RT and four times during follow-up. Functional activity on SPECT was measured using a semiquantitative perfusion DS. Pulmonary morbidity was graded by the National Cancer Institute's Common Terminology Criteria for Adverse Events version 4 for pneumonitis. Patients were divided into two groups according to the severity of RP. A total of 71 consecutive patients were included in the study. Baseline DS was associated with chronic obstructive pulmonary disease. A significant inverse correlation was found between baseline DS and forced expiratory volume in 1 s and diffusing capacity of the lung for carbon monoxide. Patients with severe RP had significantly higher baseline total lung DS (mean 5.43) than those with no or mild symptoms (mean DS 3.96, p < 0.01). PFT results were not different between these two groups. The odds ratio for total lung DS was 7.8 (95 % CI 1.9 - 31) demonstrating the ability of this parameter to predict severe RP. Adjustment for other potential confounders known to be associated with increased risk of RP was performed and did not change the odds ratio. The median follow-up time after RT was 8.4 months. The largest DS increase of 13.3 % was associated with severe RP at 3 months of follow-up (p < 0.01). The development of severe RP during follow-up was not associated with changes in PFT results. Perfusion SPECT is a valuable method for predicting severe RP and for assessing changes in regional functional perfusion after curative RT comparable with

  20. Demonstration of pulmonary perfusion heterogeneity induced by gravity and lung inflation using arterial spin labeling

    Energy Technology Data Exchange (ETDEWEB)

    Fan Li [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: fanli0930@163.com; Liu Shiyuan [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: fanli7938@chinaren.com; Xiao Xiangsheng [Department of Radiology, ChangZheng Hospital, Second Military Medical University, Shanghai 200003 (China)], E-mail: lizhaobin79@163.com; Sun Fei [GE Healthcare (China)], E-mail: Fei.sun@med.ge.com

    2010-02-15

    Objective: To evaluate the effect of gravity and lung inflation on pulmonary perfusion heterogeneity in human lung using an arterial spin labeling (ASL) sequence called flow sensitive alternating inversion recovery (FAIR). Materials and methods: Magnetic resonance imaging of lung perfusion using arterial spin labeling sequence was performed in supine position in ten healthy volunteers on a 1.5 T whole body scanner (GE Healthcare). Five coronal slices at an interval of 3 cm from dorsal to ventral (labeled as P3, P6, P9, P12, P15, sequently) were obtained when the volunteers performed breath holding on end expiration and the relative pulmonary blood flow (rPBF) was measured. Then, another coronal perfusion-weighted image of P3 slice was obtained on end inspiration. Tagging efficiency of pulmonary parenchyma with IR ({delta}SI), rPBF and area of the P3 slice were analyzed. Results: (1) Along the direction of gravity, a gradient was visually perceived as a vertical increase in rPBF. There were significant statistic differences in rPBF between any two coronal planes except that between P12 and P15. In supine position, regression coefficients of right and left lung were -4.98 and -5.16, respectively. This means that rPBF decreased 4.98 (right) and 5.16 (left) for each centimeter above the dorsal. No statistical difference was seen between ROIs placed along iso-gravitational plane. (2) For a same slice, there were significant statistic differences in {delta}SI, rPBF and area at different respiratory phases (P < 0.05). Greater {delta}SI and more perfusion were observed on end expiration than on end inspiration. The area was larger on end inspiration than on end expiration. Conclusion: Both gravity and respiratory phase are important determinants of pulmonary perfusion heterogeneity. FAIR is sensitive to demonstrate gravity- and respiratory phase-dependent differences in lung perfusion. Positioning the patient so that the area of interest is down-gravity and asking patient

  1. [Lung perfusion studies after percutaneous closure of patent ductus arteriosus using the Amplatzer Duct Occluder in children].

    Science.gov (United States)

    Parra-Bravo, José Rafael; Apolonio-Martínez, Adriana; Estrada-Loza, María de Jesús; Beirana-Palencia, Luisa Gracia; Ramírez-Portillo, César Iván

    2015-01-01

    The closure of patent ductus arteriosus with multiple devices has been associated with a reduction in lung perfusion. We evaluated the pulmonary perfusion after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder device using perfusion lung scan. Thirty patients underwent successful percutaneous patent ductus arteriosus occlusions using the Amplatzer Duct Occluder device were included in this study. Lung perfusion scans were preformed 6 months after the procedure. Peak flow velocities and protrusion of the device were analyzed by Doppler echocardiography. A left lung perfusionductus arteriosus and the minimum and maximum diameter/length of the ductus arteriosus ratio were statistically significant in patients with abnormalities of lung perfusion. It was observed protrusion the device in 6 patients with a higher maximum flow rate in the left pulmonary artery. The left lung perfusion may be compromised after percutaneous closure of patent ductus arteriosus with the Amplatzer Duct Occluder. The increased flow velocity in the origin of the left pulmonary artery can be a poor indicator of reduction in pulmonary perfusion and can occur in the absence of protrusion of the device. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  2. 86Rb Distribution in the Lung of the Rabbit with Pneumothorax

    International Nuclear Information System (INIS)

    Huh, Kap To

    1972-01-01

    86 Rb uptake of some organs and tissues, eg. both lungs, both renal cortices. small intestine, liver and skeletal muscle were studied in the control and the rabbit subjected to pneumothorax. 86 Rb in the form of chloride mixed with physiological saline was intravenously injected. The doses were 100 μc for a rabbit. The rabbits were sacrificed at intervals of 10, 20, 40, and 60 seconds after the injection of 86 Rb, by the injection of saturated KCI solution. After scarification, the organ and tissue sample were quickly removed. 86 Rb uptake in gm of the organs and tissues were measured. On the basis of uptake value, administered doses and body weight, % dose/gm tissues per 200 gm body weight was calculated. Followings were the results: 1. Pneumothorax resulted in a marked elevation in 86 Rb uptake value of collapsed lung and returned to normal level lately. 2. Contralateral lung of pneumothorax also showed marked elevation in 86 Rb uptake value and recovered to normal level. 3. Initial 86 Rb uptake value of liver, small intestine of the rabbit with pneumothorax showed some elevation as compared to control, but that of late stage were similar with control. 4. Local blood flow determination by means of 86 Rb uptake were inadequate in the collapsed lung of pneumothorax. 5. It was suggested that the mechanism for the initial elevation of 86 Rb uptake value in each organs and tissue were different from each other.

  3. Thyroid hormone stimulation of phosphatidylcholine synthesis in cultured fetal rabbit lung.

    OpenAIRE

    Ballard, P L; Hovey, M L; Gonzales, L K

    1984-01-01

    To investigate the mechanism of thyroid hormone action on pulmonary surfactant synthesis, we characterized the effect of triiodothyronine on phosphatidylcholine synthesis in cultured fetal rabbit lung. Since glucocorticoids stimulate surfactant synthesis and reduce the incidence of Respiratory Distress Syndrome in premature infants, we also examined the interaction of triiodothyronine and dexamethasone. The rate of choline incorporation into phosphatidylcholine was determined in organ culture...

  4. Extent of Spine Deformity Predicts Lung Growth and Function in Rabbit Model of Early Onset Scoliosis.

    Directory of Open Access Journals (Sweden)

    J Casey Olson

    Full Text Available Early onset deformity of the spine and chest wall (initiated <8 years of age is associated with increased morbidity at adulthood relative to adolescent onset deformity of comparable severity. Presumably, inhibition of thoracic growth during late stage alveolarization leads to an irreversible loss of pulmonary growth and thoracic function; however the natural history of this disease from onset to adulthood has not been well characterized. In this study we establish a rabbit model of early onset scoliosis to establish the extent that thoracic deformity affects structural and functional respiratory development. Using a surgical right unilateral rib-tethering procedure, rib fusion with early onset scoliosis was induced in 10 young New Zealand white rabbits (3 weeks old. Progression of spine deformity, functional residual capacity, total lung capacity, and lung mass was tracked through longitudinal breath-hold computed tomography imaging up to skeletal maturity (28 weeks old. Additionally at maturity forced vital capacity and regional specific volume were calculated as functional measurements and histo-morphometry performed with the radial alveolar count as a measure of acinar complexity. Data from tethered rib rabbits were compared to age matched healthy control rabbits (N = 8. Results show unilateral rib-tethering created a progressive spinal deformity ranging from 30° to 120° curvature, the severity of which was strongly associated with pulmonary growth and functional outcomes. At maturity rabbits with deformity greater than the median (55° had decreased body weight (89%, right (59% and left (86% lung mass, right (74% and left (69% radial alveolar count, right lung volume at total lung capacity (60%, and forced vital capacity (75%. Early treatment of spinal deformity in children may prevent pulmonary complications in adulthood and these results provide a basis for the prediction of pulmonary development from thoracic structure. This model may

  5. Ventilation/Perfusion Positron Emission Tomography—Based Assessment of Radiation Injury to Lung

    Energy Technology Data Exchange (ETDEWEB)

    Siva, Shankar, E-mail: shankar.siva@petermac.org [Department of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Sir Peter MacCallum Department of Oncology, University of Melbourne, Parkville (Australia); Hardcastle, Nicholas [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne (Australia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong (Australia); Kron, Tomas [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne (Australia); Bressel, Mathias [Department of Biostatistics and Clinical Trials, Peter MacCallum Cancer Centre, East Melbourne (Australia); Callahan, Jason [Centre for Molecular Imaging, Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia); MacManus, Michael P.; Shaw, Mark; Plumridge, Nikki [Department of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Hicks, Rodney J. [Centre for Molecular Imaging, Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia); Department of Medicine, University of Melbourne, Parkville (Australia); Steinfort, Daniel [Department of Medicine, University of Melbourne, Parkville (Australia); Department of Cancer Medicine, Peter MacCallum Cancer Centre, East Melbourne (Australia); Ball, David L. [Department of Radiation Oncology, Peter MacCallum Cancer Centre, East Melbourne (Australia); Hofman, Michael S. [Centre for Molecular Imaging, Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia); Department of Medicine, University of Melbourne, Parkville (Australia)

    2015-10-01

    Purpose: To investigate {sup 68}Ga-ventilation/perfusion (V/Q) positron emission tomography (PET)/computed tomography (CT) as a novel imaging modality for assessment of perfusion, ventilation, and lung density changes in the context of radiation therapy (RT). Methods and Materials: In a prospective clinical trial, 20 patients underwent 4-dimensional (4D)-V/Q PET/CT before, midway through, and 3 months after definitive lung RT. Eligible patients were prescribed 60 Gy in 30 fractions with or without concurrent chemotherapy. Functional images were registered to the RT planning 4D-CT, and isodose volumes were averaged into 10-Gy bins. Within each dose bin, relative loss in standardized uptake value (SUV) was recorded for ventilation and perfusion, and loss in air-filled fraction was recorded to assess RT-induced lung fibrosis. A dose-effect relationship was described using both linear and 2-parameter logistic fit models, and goodness of fit was assessed with Akaike Information Criterion (AIC). Results: A total of 179 imaging datasets were available for analysis (1 scan was unrecoverable). An almost perfectly linear negative dose-response relationship was observed for perfusion and air-filled fraction (r{sup 2}=0.99, P<.01), with ventilation strongly negatively linear (r{sup 2}=0.95, P<.01). Logistic models did not provide a better fit as evaluated by AIC. Perfusion, ventilation, and the air-filled fraction decreased 0.75 ± 0.03%, 0.71 ± 0.06%, and 0.49 ± 0.02%/Gy, respectively. Within high-dose regions, higher baseline perfusion SUV was associated with greater rate of loss. At 50 Gy and 60 Gy, the rate of loss was 1.35% (P=.07) and 1.73% (P=.05) per SUV, respectively. Of 8/20 patients with peritumoral reperfusion/reventilation during treatment, 7/8 did not sustain this effect after treatment. Conclusions: Radiation-induced regional lung functional deficits occur in a dose-dependent manner and can be estimated by simple linear models with 4D-V/Q PET

  6. Ventilation/Perfusion Positron Emission Tomography—Based Assessment of Radiation Injury to Lung

    International Nuclear Information System (INIS)

    Siva, Shankar; Hardcastle, Nicholas; Kron, Tomas; Bressel, Mathias; Callahan, Jason; MacManus, Michael P.; Shaw, Mark; Plumridge, Nikki; Hicks, Rodney J.; Steinfort, Daniel; Ball, David L.; Hofman, Michael S.

    2015-01-01

    Purpose: To investigate 68 Ga-ventilation/perfusion (V/Q) positron emission tomography (PET)/computed tomography (CT) as a novel imaging modality for assessment of perfusion, ventilation, and lung density changes in the context of radiation therapy (RT). Methods and Materials: In a prospective clinical trial, 20 patients underwent 4-dimensional (4D)-V/Q PET/CT before, midway through, and 3 months after definitive lung RT. Eligible patients were prescribed 60 Gy in 30 fractions with or without concurrent chemotherapy. Functional images were registered to the RT planning 4D-CT, and isodose volumes were averaged into 10-Gy bins. Within each dose bin, relative loss in standardized uptake value (SUV) was recorded for ventilation and perfusion, and loss in air-filled fraction was recorded to assess RT-induced lung fibrosis. A dose-effect relationship was described using both linear and 2-parameter logistic fit models, and goodness of fit was assessed with Akaike Information Criterion (AIC). Results: A total of 179 imaging datasets were available for analysis (1 scan was unrecoverable). An almost perfectly linear negative dose-response relationship was observed for perfusion and air-filled fraction (r 2 =0.99, P<.01), with ventilation strongly negatively linear (r 2 =0.95, P<.01). Logistic models did not provide a better fit as evaluated by AIC. Perfusion, ventilation, and the air-filled fraction decreased 0.75 ± 0.03%, 0.71 ± 0.06%, and 0.49 ± 0.02%/Gy, respectively. Within high-dose regions, higher baseline perfusion SUV was associated with greater rate of loss. At 50 Gy and 60 Gy, the rate of loss was 1.35% (P=.07) and 1.73% (P=.05) per SUV, respectively. Of 8/20 patients with peritumoral reperfusion/reventilation during treatment, 7/8 did not sustain this effect after treatment. Conclusions: Radiation-induced regional lung functional deficits occur in a dose-dependent manner and can be estimated by simple linear models with 4D-V/Q PET/CT imaging. These

  7. Cyclooxygenase-2-dependent bronchoconstriction in perfused rat lungs exposed to endotoxin.

    OpenAIRE

    Uhlig, S.; Nüsing, R.; von Bethmann, A.; Featherstone, R. L.; Klein, T.; Brasch, F.; Müller, K. M.; Ullrich, V.; Wendel, A.

    1996-01-01

    BACKGROUND: Lipopolysaccharides (LPS), widely used to study the mechanisms of gram-negative sepsis, increase airway resistance by constriction of terminal bronchioles. The role of the cyclooxygenase (COX) isoenzymes and their prostanoid metabolites in this process was studied. MATERIALS AND METHODS: Pulmonary resistance, the release of thromboxane (TX) and the expression of COX-2 mRNA were measured in isolated blood-free perfused rat lungs exposed to LPS. RESULTS: LPS induced the release of T...

  8. The histopathologic reaction of rabbit lungs after intrabronchial application of contrast agents

    International Nuclear Information System (INIS)

    Lim, Hyo Soon; Kim, Jae Kyu; Shen, Yu Lan; Oh, Jeong Won; Chang, Nam Kyu; Shin, Sang Soo; Park, Jin Gyoon; Kang, Heoung Keun

    2006-01-01

    The aim of this study was to determine a safe gastrointestinal contrast agent that could be used in various clinical situations where there is a risk of aspiration using a rabbit model. 30 healthy white rabbits were used. The rabbits were divided into 5 groups containing six animals each, one control group (anesthesia only) and 4 groups receiving various contrast agents [Solotop (Barium sulphate suspension), Gastrografin (sodium and meglumine amidotrizoate), and Telebrix (Meglumine ioxitalamate), Visipaque (Iodixanol)]. The contrast agents were injected selectively into a main bronchus via a catheter inserted under fluoroscopy guidance. The rabbits were sacrificed either 1 day or 7 days after injecting the contrast agents, and the tissue reaction of the bronchi and lungs were examined both macro-and microscopically. The level of alveolar septal thickening, peribronchiolar lymphocytic infiltration, pulmonary congestion and edema, inflammatory exudate in the alveoli or bronchiolar lumina, microabscess formation, necrosis, pigmentation of materials injected, and fibropurulent pleurisy were evaluated and graded according to the severity as follows: no change, mild, moderate, marked in degree. The common microscopic findings were alveolar septal thickening and peribronchiolar lymphocytic infiltration. Pulmonary congestion and edema, inflammatory exudate in the alveoli of bronchiolar lumina were observed in 21 out of 24 rabbits receiving the contrast agents. Pigmentation of the materials injected was observed only in the group receiving Solotop. An inflammatory exudate in the alveoli and bronchiolar/bronchial lumina, microabscess formation, and necrosis were noted in most groups, but was more frequent and severe in the group receiving Gastrografin. The histopathological reactions of the rabbit lungs after the intrabronchial application of a contrast agent showed variable degrees of inflammatory reaction. Gastrografin produced most severe and extensive reaction, Solotop

  9. A new application of Bull's eye analysis to lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yasui, Kotaro; Kohno, Yoshihiro; Akaki, Shiro; Hasegawa, Mari; Nakagawa, Tomio; Simizu, Mitsuharu; Takeda, Yoshihiro; Hiraki, Yoshio; Nagaya, Isao.

    1990-01-01

    Technetium-99m macroaggregated albumin lung perfusion scintigraphy was performed and evaluated semiquantitatively by Bull's eye analysis in 24, including 7 with central pulmonary carcinoma, 3 with hypersensitivity pneumonitis (HP), 3 with diffuse panbronchiolitis (DPB) and 11 normal subjects. First, whole lung field was divided into three regions by three concentric circles. And then radial axes were projected from the center to define 36 sectors, 10 degree each. The counts of each sector was calculated and Bull's eye image and circumferential profile curve were displayed. The patient's map was compared with the lower limit of normal (mean-2 SD), and the extent score (ES) and the severity score (SS) were calculated. The ES was 0.25±0.12 in pulmonary carcinoma (n=7), 0.08±0.07 in HP (n=3), 0.06±0.04 in DPB (n=3). The SS was 26.39±15.17 in pulmonary carcinoma, 4.75±5.57 in HP, 4.29±3.67 in DPB. In one case of central pulmonary carcinoma, segmental perfusion defect was evaluated semiquantitatively by Bull's eye image and circumferential profile curve. And in one case of HP, the change of regional pulmonary blood flow could be followed easily using extent and severity map. This new application of Bull's eye analysis to lung perfusion scintigraphy might be useful to evaluate regional pulmonary blood flow. (author)

  10. Assessing tumor treatment response and prognosis in non-small cell lung cancer with perfusion CT

    International Nuclear Information System (INIS)

    Wang Jianwei; Wu Ning; Song Ying

    2010-01-01

    Objective: To prospectively investigate whether any of the perfusion parameters would predict early tumor response to chemotherapy and/or radiotherapy and prognosis in non-small cell lung cancer (NSCLC). Methods: In a prospective series, Perfusion CT were performed in 152 patients suspected lung cancer with 16-slice or 8-slice multislice CT. Contrast medium (50 ml) was injected at a rate of 4 ml/s with a power injector. The scanning delay was 10 seconds and the scanning time was 50 seconds. Among 152 patients, 123 patients were proved lung cancer by pathology. With the perfusion 3.0 software, the parameters including blood flow (BF), blood volume (BV), mean transit time (MTT) and capillary permeability surface area product (PS) were calculated. The perfusion image quality was evaluated on a 4-1eveal scale. The treatment response after chemotherapy and (or) radiotherapy was assessed with Response Evaluation Criteria in Solid Tumors (RECIST), and then the relationship between perfusion parameters with early tumor response to chemotherapy and (or) radiotherapy was evaluated. Student t test and Kaplan-Meier estimates were used for data analysis. Results: In 84 patients (68.3%), the perfusion image quality was staged level 2 (moderate) and level 3 (good). Among them, 35 patients with NSCLC were assessed with RECIST after chemotherapy and (or) radiotherapy. In these 35 patients, The BF of responders and nonresponders was (81.0 ± 33.6)and (56.3 ± 23.1) ml · min -1 ·100 g -1 , respectively, which was significantly different(t=2.393, P=0.023). The median PFS of low-BF group (BF ≤ 80 ml · min -1 · 100 g -1 ) and high-BF group (BF>80 ml · min -1 · 100 g -1 ) was 11.8 and 8.0 months respectively (P>0.05), and the median PFS of low-BV group (BF ≤ 6 ml/100 g -1 ) and high-BV group (BF>6 ml/100 g -1 ) was 9.2 and 8.0 months respectively(P>0.05), both of them were not significantly different. Conclusion: NSCLC in high perfusion are relatively sensitive to chemotherapy

  11. Radiation-Induced Reductions in Regional Lung Perfusion: 0.1-12 Year Data From a Prospective Clinical Study

    International Nuclear Information System (INIS)

    Zhang Junan; Ma Jinli; Zhou Sumin; Hubbs, Jessica L.; Wong, Terence Z.; Folz, Rodney J.; Evans, Elizabeth S.; Jaszczak, Ronald J.; Clough, Robert; Marks, Lawrence B.

    2010-01-01

    Purpose: To assess the time and regional dependence of radiation therapy (RT)-induced reductions in regional lung perfusion 0.1-12 years post-RT, as measured by single photon emission computed tomography (SPECT) lung perfusion. Materials/Methods: Between 1991 and 2005, 123 evaluable patients receiving RT for tumors in/around the thorax underwent SPECT lung perfusion scans before and serially post-RT (0.1-12 years). Registration of pre- and post-RT SPECT images with the treatment planning computed tomography, and hence the three-dimensional RT dose distribution, allowed changes in regional SPECT-defined perfusion to be related to regional RT dose. Post-RT follow-up scans were evaluated at multiple time points to determine the time course of RT-induced regional perfusion changes. Population dose response curves (DRC) for all patients at different time points, different regions, and subvolumes (e.g., whole lungs, cranial/caudal, ipsilateral/contralateral) were generated by combining data from multiple patients at similar follow-up times. Each DRC was fit to a linear model, and differences statistically analyzed. Results: In the overall groups, dose-dependent reductions in perfusion were seen at each time post-RT. The slope of the DRC increased over time up to 18 months post-RT, and plateaued thereafter. Regional differences in DRCs were only observed between the ipsilateral and contralateral lungs, and appeared due to tumor-associated changes in regional perfusion. Conclusions: Thoracic RT causes dose-dependent reductions in regional lung perfusion that progress up to ∼18 months post-RT and persists thereafter. Tumor shrinkage appears to confound the observed dose-response relations. There appears to be similar dose response for healthy parts of the lungs at different locations.

  12. Assessment of the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level in patients with emphysema

    International Nuclear Information System (INIS)

    Ley-Zaporozhan, Julia; Ley, Sebastian; Eberhardt, Ralf; Weinheimer, Oliver; Fink, Christian; Puderbach, Michael; Eichinger, Monika; Herth, Felix; Kauczor, Hans-Ulrich

    2007-01-01

    Purpose: To assess the relationship between lung parenchymal destruction and impaired pulmonary perfusion on a lobar level using CT and MRI in patients with emphysema. Material and methods: Forty-five patients with severe emphysema (GOLD III and IV) underwent inspiratory 3D-HRCT and contrast-enhanced MR-perfusion (1.5T; 3.5 mm x 1.9 mm x 4 mm). 3D-HRCT data was analyzed using a software for detection and visualization of emphysema. Emphysema was categorized in four clusters with different volumes and presented as overlay on the CT. CT and lung perfusion were visually analyzed for three lobes on each side using a four-point-score to grade the abnormalities on CT (1: predominantly small emphysema-clusters to 4: >75% large emphysema-clusters) and MRI (1: normal perfusion to 4: no perfusion). Results: A total of 270 lobes were evaluated. At CT, the score was 1 for 9 lobes, 2 for 43, 3 for 77, and 4 for 141 lobes. At MRI, the score was 1 for 13 lobes, 2 for 45, 3 for 92, and 4 for 120 lobes. Matching of lung parenchymal destruction and reduced perfusion was found in 213 lobes (weighted kappa = 0.8). The score was higher on CT in 44, and higher on MRI in 13 lobes. Conclusion: 3D-HRCT and 3D MR-perfusion show a high lobar agreement between parenchymal destruction and reduction of perfusion in patients with severe emphysema

  13. Analysis of decrease in lung perfusion blood volume with occlusive and non-occlusive pulmonary embolisms

    International Nuclear Information System (INIS)

    Ikeda, Yohei; Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Ishikawa, Hiroyuki; Yamazaki, Motohiko; Noto, Yoshiyuki; Aoyama, Hidefumi

    2014-01-01

    Highlights: • The proportion of preserved PE lesions in the non-occlusive group was 76.7% (33/43). • HUs of the iodine map were significantly higher in the non-occlusive group than in the occlusive group. • There was no significant difference in HUs between the non-occlusive and corresponding normal group. - Abstract: Purpose: The aim of this study was to determine if lung perfusion blood volume (lung PBV) with non-occlusive pulmonary embolism (PE) differs quantitatively and visually from that with occlusive PE and to investigate if lung PBV with non-occlusive PE remains the same as that without PE. Materials and methods: Totally, 108 patients suspected of having acute PE underwent pulmonary dual-energy computed tomography angiography (DECTA) between April 2011 and January 2012. Presence of PE on DECTA was evaluated by one radiologist. Two radiologists visually evaluated the PE distribution (segmental or subsegmental) and its nature (occlusive or non-occlusive) on DECTA and classified perfusion in lung PBV as “decreased,” “slightly decreased,” and “preserved”. Two radiologists used a lung PBV application to set a region of interest (ROI) in the center of the lesion and measured HU values of an iodine map. In the same slice as the ROI of the lesion and close to the lesion, another ROI was set in the normal perfusion area without PE, and HUs were measured. The proportion of lesions was compared between the occlusive and non-occlusive groups. HUs were compared among the occlusive, non-occlusive, and corresponding normal groups. Results: Twenty-five patients had 80 segmental or subsegmental lesions. There were 37 and 43 lesions in the occlusive and non-occlusive groups, respectively. The proportion of decreased lesions was 73.0% (27/37) in the occlusive group, while that of preserved lesions in the non-occlusive group was 76.7% (33/43). There was a significant difference in the proportion of lesions (P < 0.001) between the two groups. HUs of the

  14. A novel method for right one-lung ventilation modeling in rabbits.

    Science.gov (United States)

    Xu, Ze-Ping; Gu, Lian-Bing; Bian, Qing-Ming; Li, Peng-Yi; Wang, Li-Jun; Chen, Xiao-Xiang; Zhang, Jing-Yuan

    2016-08-01

    There is no standard method by which to establish a right one-lung ventilation (OLV) model in rabbits. In the present study, a novel method is proposed to compare with two other methods. After 0.5 h of baseline two-lung ventilation (TLV), 40 rabbits were randomly divided into sham group (TLV for 3 h as a contrast) and three right-OLV groups (right OLV for 3 h with different methods): Deep intubation group, clamp group and blocker group (deeply intubate the self-made bronchial blocker into the left main bronchus, the novel method). These three methods were compared using a number of variables: Circulation by heart rate (HR), mean arterial pressure (MAP); oxygenation by arterial blood gas analysis; airway pressure; lung injury by histopathology; and time, blood loss, success rate of modeling. Following OLV, compared with the sham group, arterial partial pressure of oxygen and arterial hemoglobin oxygen saturation decreased, peak pressure increased and lung injury scores were higher in three OLV groups at 3 h of OLV. All these indexes showed no differences between the three OLV groups. During right-OLV modeling, less time was spent in the blocker group (6±2 min), compared with the other two OLV groups (13±4 min in deep intubation group, Pright-OLV model in rabbits.

  15. Transcriptome Analysis of the Preterm Rabbit Lung after Seven Days of Hyperoxic Exposure.

    Directory of Open Access Journals (Sweden)

    Thomas Salaets

    Full Text Available The neonatal management of preterm born infants often results in damage to the developing lung and subsequent morbidity, referred to as bronchopulmonary dysplasia (BPD. Animal models may help in understanding the molecular processes involved in this condition and define therapeutic targets. Our goal was to identify molecular pathways using the earlier described preterm rabbit model of hyperoxia induced lung-injury. Transcriptome analysis by mRNA-sequencing was performed on lungs from preterm rabbit pups born at day 28 of gestation (term: 31 days and kept in hyperoxia (95% O2 for 7 days. Controls were preterm pups kept in normoxia. Transcriptomic data were analyzed using Array Studio and Ingenuity Pathway Analysis (IPA, in order to identify the central molecules responsible for the observed transcriptional changes. We detected 2217 significantly dysregulated transcripts following hyperoxia, of which 90% could be identified. Major pathophysiological dysregulations were found in inflammation, lung development, vascular development and reactive oxygen species (ROS metabolism. To conclude, amongst the many dysregulated transcripts, major changes were found in the inflammatory, oxidative stress and lung developmental pathways. This information may be used for the generation of new treatment hypotheses for hyperoxia-induced lung injury and BPD.

  16. Acute lung injury and persistent small airway disease in a rabbit model of chlorine inhalation

    Energy Technology Data Exchange (ETDEWEB)

    Musah, Sadiatu; Schlueter, Connie F.; Humphrey, David M. [Department of Environmental and Occupational Health Sciences, School of Public Health and Information Sciences, University of Louisville, Louisville, KY (United States); Powell, Karen S. [Research Resource Facilities, University of Louisville, Louisville, KY (United States); Roberts, Andrew M. [Department of Physiology, University of Louisville, Louisville, KY (United States); Hoyle, Gary W., E-mail: Gary.Hoyle@louisville.edu [Department of Environmental and Occupational Health Sciences, School of Public Health and Information Sciences, University of Louisville, Louisville, KY (United States)

    2017-01-15

    Chlorine is a pulmonary toxicant to which humans can be exposed through accidents or intentional releases. Acute effects of chlorine inhalation in humans and animal models have been well characterized, but less is known about persistent effects of acute, high-level chlorine exposures. In particular, animal models that reproduce the long-term effects suggested to occur in humans are lacking. Here, we report the development of a rabbit model in which both acute and persistent effects of chlorine inhalation can be assessed. Male New Zealand White rabbits were exposed to chlorine while the lungs were mechanically ventilated. After chlorine exposure, the rabbits were extubated and were allowed to survive for up to 24 h after exposure to 800 ppm chlorine for 4 min to study acute effects or up to 7 days after exposure to 400 ppm for 8 min to study longer term effects. Acute effects observed 6 or 24 h after inhalation of 800 ppm chlorine for 4 min included hypoxemia, pulmonary edema, airway epithelial injury, inflammation, altered baseline lung mechanics, and airway hyperreactivity to inhaled methacholine. Seven days after recovery from inhalation of 400 ppm chlorine for 8 min, rabbits exhibited mild hypoxemia, increased area of pressure–volume loops, and airway hyperreactivity. Lung histology 7 days after chlorine exposure revealed abnormalities in the small airways, including inflammation and sporadic bronchiolitis obliterans lesions. Immunostaining showed a paucity of club and ciliated cells in the epithelium at these sites. These results suggest that small airway disease may be an important component of persistent respiratory abnormalities that occur following acute chlorine exposure. This non-rodent chlorine exposure model should prove useful for studying persistent effects of acute chlorine exposure and for assessing efficacy of countermeasures for chlorine-induced lung injury. - Highlights: • A novel rabbit model of chlorine-induced lung disease was developed.

  17. Saline-enhanced radiofrequency thermal ablation of the lung: a feasibility study in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Kim, Sang Won; Li, Chun Ai; Youk, Ji Hyun; Kim, Young Kon; Jin, Zhewu; Chung, Myoung Ja [Chonbuk National University Medical School, Jeonju (Korea, Republic of); Lee, Mi Suk [Yangi Hospital, Seoul (Korea, Republic of)

    2002-12-01

    To assess the feasibility and safety of CT-guided percutaneous transthoracic radiofrequency ablation (RFA) with saline infusion of pulmonary tissue in rabbits. Twenty-eight New Zealand White rabbits were divided into two groups: an RFA group (n=10) and a saline-enhanced RFA (SRFA) group (n=18). In the RFA group, percutaneous RFA of the lung was performed under CT guidance and using a 17-gauge internally cooled electrode. In the SRFA group, 1.5 ml of 0.9% saline was infused slowly through a 21-gauge, polyteflon-coated Chiba needle prior to and during RFA. Lesion size and the healing process were studied in rabbits sacrificed at times from the day following treatment to three weeks after, and any complications were noted. In the SRFA group, the mean diameter (12.5{+-}1.6 mm) of acute RF lesions was greater than that of RFA lesions (8.5{+-}1.4 mm) (p < .05). The complications arising in 12 cases were pneumothorax (n=8), thermal injury to the chest wall (n=2), hemothorax (n=1), and lung abscess (n=1). Although procedure-related complications tended to occur more frequently in the SRFA group (55.6%) than in the RFA group (20%), the difference was not statistically significant (p .11). Saline-enhanced RFA of pulmonary tissue in rabbits produces more extensive coagulation necrosis than conventional RFA procedures, without adding substantial risk of serious complications.

  18. Bacterial and Pneumocystis Infections in the Lungs of Gene-Knockout Rabbits with Severe Combined Immunodeficiency

    Directory of Open Access Journals (Sweden)

    Jun Song

    2018-03-01

    Full Text Available Using the CRISPR/Cas9 gene-editing technology, we recently produced a number of rabbits with mutations in immune function genes, including FOXN1, PRKDC, RAG1, RAG2, and IL2RG. Seven founder knockout rabbits (F0 and three male IL2RG null (−/y F1 animals demonstrated severe combined immunodeficiency (SCID, characterized by absence or pronounced hypoplasia of the thymus and splenic white pulp, and absence of immature and mature T and B-lymphocytes in peripheral blood. Complete blood count analysis showed severe leukopenia and lymphocytopenia accompanied by severe neutrophilia. Without prophylactic antibiotics, the SCID rabbits universally succumbed to lung infections following weaning. Pathology examination revealed severe heterophilic bronchopneumonia caused by Bordetella bronchiseptica in several animals, but a consistent feature of lung lesions in all animals was a severe interstitial pneumonia caused by Pneumocystis oryctolagi, as confirmed by histological examination and PCR analysis of Pneumocystis genes. The results of this study suggest that these SCID rabbits could serve as a useful model for human SCID to investigate the disease pathogenesis and the development of gene and drug therapies.

  19. Bacterial and Pneumocystis Infections in the Lungs of Gene-Knockout Rabbits with Severe Combined Immunodeficiency

    Science.gov (United States)

    Song, Jun; Wang, Guoshun; Hoenerhoff, Mark J.; Ruan, Jinxue; Yang, Dongshan; Zhang, Jifeng; Yang, Jibing; Lester, Patrick A.; Sigler, Robert; Bradley, Michael; Eckley, Samantha; Cornelius, Kelsey; Chen, Kong; Kolls, Jay K.; Peng, Li; Ma, Liang; Chen, Yuqing Eugene; Sun, Fei; Xu, Jie

    2018-01-01

    Using the CRISPR/Cas9 gene-editing technology, we recently produced a number of rabbits with mutations in immune function genes, including FOXN1, PRKDC, RAG1, RAG2, and IL2RG. Seven founder knockout rabbits (F0) and three male IL2RG null (−/y) F1 animals demonstrated severe combined immunodeficiency (SCID), characterized by absence or pronounced hypoplasia of the thymus and splenic white pulp, and absence of immature and mature T and B-lymphocytes in peripheral blood. Complete blood count analysis showed severe leukopenia and lymphocytopenia accompanied by severe neutrophilia. Without prophylactic antibiotics, the SCID rabbits universally succumbed to lung infections following weaning. Pathology examination revealed severe heterophilic bronchopneumonia caused by Bordetella bronchiseptica in several animals, but a consistent feature of lung lesions in all animals was a severe interstitial pneumonia caused by Pneumocystis oryctolagi, as confirmed by histological examination and PCR analysis of Pneumocystis genes. The results of this study suggest that these SCID rabbits could serve as a useful model for human SCID to investigate the disease pathogenesis and the development of gene and drug therapies. PMID:29593714

  20. Evaluation of pN factors in patients with primary lung cancer by using perfusion, inhalation and ventilation studies

    International Nuclear Information System (INIS)

    Tamai, Toyosato; Tanabe, Masatada; Satoh, Katashi

    1987-01-01

    The interpretation of scintigraphic patterns and the role of pathophysiological mechanisms in patients with primary lung cancer were investigated. To determine the relative roles of perfusion, inhalation and ventilation scintigraphy, the relationship between the count ratio of the affected side to the healthy side and the post-surgical histological lymph nodes factors were observed in this study. These scintigraphic count ratio's in patients with primary lung cancer did not reflect the pN factors except in the perfusion study in patients with hilar primary lung cancer. (author)

  1. Studies on the correlation between pre-and post-operative perfusion scintigraphy and differential spirometry in operated lungs

    International Nuclear Information System (INIS)

    Kaseda, Shizuka; Ikeda, Takaaki; Sakai, Tadaaki; Tomaru, Hiroko; Ishihara, Tsuneo; Kikuchi, Keiichi.

    1982-01-01

    For the purpose of clarifying the relationship between the percentage of perfusion and that of vital capacity or oxygen uptake on the affected lung, perfusion scintigraphy using sup(99m)Tc-MAA and differential spirometry were performed in twenty patients including sixteen patients with lung cancer. Both examinations were performed before and after the operation. The results are as follows: (1) There is a significant correlation between the percentage of perfusion and that of vital capacity or oxygen uptake of the affected lung before and after the operation. (2) The estimation of the percentage of vital capacity or oxygen uptake of the affected lung is possible by combining the spirometry and sup(99m)Tc-MAA pulmonary scintigraphy. (author)

  2. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo; Park, Sang Hyub [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2017-11-15

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy. (orig.)

  3. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Park, Sang Hyub

    2017-01-01

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy. (orig.)

  4. Diagnosis of thromboembolic disease: combined ventilation perfusion lung scan and compression ultrasonography

    International Nuclear Information System (INIS)

    Dadparvar, S.; Woods, K.; Magno, R.M.; Sabatino, J. C.; Patil, S.; Dou, Y.

    2002-01-01

    The clinical management of pulmonary embolism and deep venous thrombosis of the legs are similar and require prolonged anticoagulation therapy. The standard diagnostic approach in patients suspected of pulmonary embolism is ventilation-perfusion (V/Q) lung scan and compression ultrasonography to detect deep venous thrombosis. This retrospective study analyzed the role of V Q lung scan and compression ultrasonography in detection of thromboembolic disease. One hundred-twenty consecutive patients (65 female, 55 male) age range 18-95 (mean age 60.7) suspected for pulmonary embolism underwent concomitant V/Q lung scan and compression ultrasonography of the lower extremities. The clinical and radiographic correlation was performed. Of patients with non-diagnostic (low or intermediate probability ) lung scans, 15.4 % (14/91) received anticoagulation therapy for pulmonary embolism. This patients had either high pre-clinical suspicion for PE or underwent pulmonary arterio gram. However, there was an additional 7 % (7/91) increase in the number of patients who received anticoagulation therapy based on the results of ultrasound with confidence interval (3 %-16 %). We conclude that V/Q lung scan is a more sensitive examination for thromboembolic disease, and has a high negative predictive value. Ultrasonography of lower extremities demonstrated higher specificity and positive value. Among patients with non-diagnostic lung scan, the detection rate of thromboembolic disease is improved with addition of ultrasound

  5. Development and use of a new perfusion technique to study glucose metabolism of the aortic wall in normal and alloxan-diabetic rabbits

    International Nuclear Information System (INIS)

    Brown, B.J.M.

    1985-01-01

    This study investigated (1) possible alterations in glucose uptake and utilization in the perfused, normal, and diabetic vascular wall of rabbits and (2) the effects thereon of insulin and exogenous glucose concentration. Part I involved development and characterization of an in vitro perfusion technique that closely reproduced predetermined in vivo conditions of aortic blood flow, arterial blood pressure, heart rate and pulse pressure. The responsiveness of the preparation to vasoactive agents was assessed with concentrations of norepinephrine (NE) from 10 -9 to 10 -4 M. In Part II, the effects of NE-induced tension development on glucose metabolism were determined by perfusion with oxygenated physiological salt solution (PSS) containing 7 mM glucose and tracer amounts of uniformly labeled 14 C-glucose. Aortas from 8 week-diabetic rabbits were perfused under similar conditions employing a NE infusion in the presence or absence of insulin (150 uU/ml) and variable levels of glucose. Effects of NE-induced tension development include an apparent increase (39%) in glucose uptake and a twofold increase in 14 CO 2 and lactate production. Aortas from diabetic rabbits perfused with PSS containing 7 mM glucose demonstrated marked decreases in glucose uptake (74%), 14 CO 2 (68%), lactate (30%), total tissue glycogen (75%) and labeled tissue phospholipids (70%). Insulin or elevation of exogenous glucose to 25 mM (diabetic levels) normalized glucose uptake, but had differential effects on the pattern of substrate utilization. The marked alterations of glucose metabolism in the diabetic state may contribute to the functional changes observed in diabetic blood vessels

  6. Correlation of iodine uptake and perfusion parameters between dual-energy CT imaging and first-pass dual-input perfusion CT in lung cancer.

    Science.gov (United States)

    Chen, Xiaoliang; Xu, Yanyan; Duan, Jianghui; Li, Chuandong; Sun, Hongliang; Wang, Wu

    2017-07-01

    To investigate the potential relationship between perfusion parameters from first-pass dual-input perfusion computed tomography (DI-PCT) and iodine uptake levels estimated from dual-energy CT (DE-CT).The pre-experimental part of this study included a dynamic DE-CT protocol in 15 patients to evaluate peak arterial enhancement of lung cancer based on time-attenuation curves, and the scan time of DE-CT was determined. In the prospective part of the study, 28 lung cancer patients underwent whole-volume perfusion CT and single-source DE-CT using 320-row CT. Pulmonary flow (PF, mL/min/100 mL), aortic flow (AF, mL/min/100 mL), and a perfusion index (PI = PF/[PF + AF]) were automatically generated by in-house commercial software using the dual-input maximum slope method for DI-PCT. For the dual-energy CT data, iodine uptake was estimated by the difference (λ) and the slope (λHU). λ was defined as the difference of CT values between 40 and 70 KeV monochromatic images in lung lesions. λHU was calculated by the following equation: λHU = |λ/(70 - 40)|. The DI-PCT and DE-CT parameters were analyzed by Pearson/Spearman correlation analysis, respectively.All subjects were pathologically proved as lung cancer patients (including 16 squamous cell carcinoma, 8 adenocarcinoma, and 4 small cell lung cancer) by surgery or CT-guided biopsy. Interobserver reproducibility in DI-PCT (PF, AF, PI) and DE-CT (λ, λHU) were relatively good to excellent (intraclass correlation coefficient [ICC]Inter = 0.8726-0.9255, ICCInter = 0.8179-0.8842; ICCInter = 0.8881-0.9177, ICCInter = 0.9820-0.9970, ICCInter = 0.9780-0.9971, respectively). Correlation coefficient between λ and AF, and PF were as follows: 0.589 (P input CT perfusion analysis method can be applied to assess blood supply of lung cancer patients. Preliminary results demonstrated that the iodine uptake relevant parameters derived from DE-CT significantly correlated with perfusion

  7. Reproducibility of Lobar Perfusion and Ventilation Quantification Using SPECT/CT Segmentation Software in Lung Cancer Patients.

    Science.gov (United States)

    Provost, Karine; Leblond, Antoine; Gauthier-Lemire, Annie; Filion, Édith; Bahig, Houda; Lord, Martin

    2017-09-01

    Planar perfusion scintigraphy with 99m Tc-labeled macroaggregated albumin is often used for pretherapy quantification of regional lung perfusion in lung cancer patients, particularly those with poor respiratory function. However, subdividing lung parenchyma into rectangular regions of interest, as done on planar images, is a poor reflection of true lobar anatomy. New tridimensional methods using SPECT and SPECT/CT have been introduced, including semiautomatic lung segmentation software. The present study evaluated inter- and intraobserver agreement on quantification using SPECT/CT software and compared the results for regional lung contribution obtained with SPECT/CT and planar scintigraphy. Methods: Thirty lung cancer patients underwent ventilation-perfusion scintigraphy with 99m Tc-macroaggregated albumin and 99m Tc-Technegas. The regional lung contribution to perfusion and ventilation was measured on both planar scintigraphy and SPECT/CT using semiautomatic lung segmentation software by 2 observers. Interobserver and intraobserver agreement for the SPECT/CT software was assessed using the intraclass correlation coefficient, Bland-Altman plots, and absolute differences in measurements. Measurements from planar and tridimensional methods were compared using the paired-sample t test and mean absolute differences. Results: Intraclass correlation coefficients were in the excellent range (above 0.9) for both interobserver and intraobserver agreement using the SPECT/CT software. Bland-Altman analyses showed very narrow limits of agreement. Absolute differences were below 2.0% in 96% of both interobserver and intraobserver measurements. There was a statistically significant difference between planar and SPECT/CT methods ( P software is highly reproducible. This tridimensional method yields statistically significant differences in measurements for right lung lobes when compared with planar scintigraphy. We recommend that SPECT/CT-based quantification be used for all lung

  8. Effective avoidance of a functional spect-perfused lung using intensity modulated radiotherapy (IMRT) for non-small cell lung cancer (NSCLC): An update of a planning study

    International Nuclear Information System (INIS)

    Lavrenkov, Konstantin; Singh, Shalini; Christian, Judith A.; Partridge, Mike; Nioutsikou, Elena; Cook, Gary; Bedford, James L.; Brada, Michael

    2009-01-01

    IMRT and 3-dimensional conformal radiotherapy (3-DCRT) plans of 25 patients with non-small cell lung (NSCLC) were compared in terms of planning target volume (PTV) coverage and sparing of functional lung (FL) defined by a SPECT perfusion scan. IMRT resulted in significant reduction of functional V 20 and mean lung dose in stage III patients with inhomogeneous hypoperfusion. If the dose to FL is shown to be the determinant of lung toxicity, IMRT would allow for effective dose escalation by specific avoidance of functional lung.

  9. Local and systemic effects of fibrin and cyanoacrylate adhesives on lung lesions in rabbits

    Directory of Open Access Journals (Sweden)

    Marcus V.H. Carvalho

    Full Text Available OBJECTIVES: Tissue adhesives can be used to prevent pulmonary air leaks, which frequently occur after lung interventions. The objective of this study is to evaluate local and systemic effects of fibrin and cyanoacrylate tissue adhesives on lung lesions in rabbits. METHODS: Eighteen rabbits were submitted to videothoracoscopy + lung incision alone (control or videothoracoscopy + lung incision + local application of fibrin or cyanoacrylate adhesive. Blood samples were collected and assessed for leukocyte, neutrophil and lymphocyte counts and interleukin-8 levels preoperatively and at 48 hours and 28 days post-operatively. After 28 days, the animals were euthanized for gross examination of the lung surface, and lung fragments were excised for histopathological analysis. RESULTS: Fibrin and cyanoacrylate produced similar adhesion scores of the lung to the parietal pleura. Microscopic analysis revealed uniform low-cellular tissue infiltration in the fibrin group and an intense tissue reaction characterized by dense inflammatory infiltration of granulocytes, giant cells and necrosis in the cyanoacrylate group. No changes were detected in the leukocyte, neutrophil or lymphocyte count at any time-point, while the interleukin-8 levels were increased in the fibrin and cyanoacrylate groups after 48 hours compared with the pre-operative control levels (p<0.01. CONCLUSION: Both adhesive agents promoted normal tissue healing, with a more pronounced local inflammatory reaction observed for cyanoacrylate. Among the serum markers of inflammation, only the interleukin-8 levels changed post-operatively, increasing after 48 hours and decreasing after 28 days to levels similar to those of the control group in both the fibrin and cyanoacrylate groups.

  10. Preserving Functional Lung Using Perfusion Imaging and Intensity-Modulated Radiation Therapy for Advanced-Stage Non-Small Cell Lung Cancer

    International Nuclear Information System (INIS)

    Shioyama, Yoshiyuki; Jang, Si Young; Liu, H. Helen; Guerrero, Thomas; Wang, Xuanmin; Gayed, Isis W.; Erwin, William D.; Liao, Zhongxing; Chang, Joe Y.; Jeter, Melenda; Yaremko, Brian P.; Borghero, Yerko O.; Cox, James D.; Komaki, Ritsuko; Mohan, Radhe

    2007-01-01

    Purpose: To assess quantitatively the impact of incorporating functional lung imaging into intensity-modulated radiation therapy planning for locally advanced non-small cell lung cancer (NSCLC). Methods and Materials: Sixteen patients with advanced-stage NSCLC who underwent radiotherapy were included in this study. Before radiotherapy, each patient underwent lung perfusion imaging with single-photon-emission computed tomography and X-ray computed tomography (SPECT-CT). The SPECT-CT was registered with simulation CT and was used to segment the 50- and 90-percentile hyperperfusion lung (F50 lung and F90 lung). Two IMRT plans were designed and compared in each patient: an anatomic plan using simulation CT alone and a functional plan using SPECT-CT in addition to the simulation CT. Dosimetric parameters of the two types of plans were compared in terms of tumor coverage and avoidance of normal tissues. Results: In incorporating perfusion information in IMRT planning, the median reductions in the mean doses to the F50 and F90 lung in the functional plan were 2.2 and 4.2 Gy, respectively, compared with those in the anatomic plans. The median reductions in the percentage of volume irradiated with >5 Gy, >10 Gy, and >20 Gy in the functional plans were 7.1%, 6.0%, and 5.1%, respectively, for F50 lung, and 11.7%, 12.0%, and 6.8%, respectively, for F90 lung. A greater degree of sparing of the functional lung was achieved for patients with large perfusion defects compared with those with relatively uniform perfusion distribution. Conclusion: Function-guided IMRT planning appears to be effective in preserving functional lung in locally advanced-stage NSCLC patients

  11. Xenon ventilation-perfusion lung scans. The early diagnosis of inhalation injury

    International Nuclear Information System (INIS)

    Schall, G.L.; McDonald, H.D.; Carr, L.B.; Capozzi, A.

    1978-01-01

    The use of xenon Xe-133 ventilation-perfusion lung scans for the early diagnosis of inhalation injury was evaluated in 67 patients with acute thermal burns. Study results were interpreted as normal if there was complete pulmonary clearance of the radioactive gas by 150 seconds. Thirty-two scans were normal, 32 abnormal, and three technically inadequate. There were three true false-positive study results and one false-negative study result. Good correlation was found between the scan results and various historical, physical, and laboratory values currently used to evaluate inhalation injury. The scans appeared to be the most sensitive method for the detection of early involvement, often being abnormal several days before the chest roentgenogram. Xenon lung scanning is a safe, easy, accurate, and sensitive method for the early diagnosis of inhalation injury and has important therapeutic and prognostic implications as well

  12. Effects of isoproterenol on distribution of perfusion in embolized dog lungs

    International Nuclear Information System (INIS)

    Shepard, J.W. Jr.; Hauer, D.; Sgroi, V.; Moser, K.M.

    1979-01-01

    In 19 mechanically ventilated, anesthetized dogs, autologous venous thrombi were formed in the inferior vena cava and subsequently released. Serial perfusion lung scintigrams revealed the postembolic distribution of pulmonary blood flow before, during, and after the infusion of isoproterenol at 2.2 μg/min. Isoproterenol failed to restore perfusion to embolically occluded regions. When reperfusion occurred it was attributable to clot resolution. Gas exchange and hemodynamic measurements obtained in seven thromboembolized animals showed no scan evidence of reperfusion during the isoproterenol infusion. After embolization, cardiac output increased from 1.7 to 2.6 liter/min (p 2 from 38.0 to 45.3 mm Hg (p 2 to 50.7 mm Hg, along with a decrease in pulmonary vascular resistance from the postembolic mean of 448 to 246 dynes.sec.cm -5 (p < 0.05). Perfusion defects following acute pulmonary thromboembolization are not altered by the infusion of the potent pulmonary vasodilator, isoproterenol. Infusion of this drug following thromboembolization may have potential therapeutic benefit by reducing pulmonary vascular resistance, increasing cardiac output, and elevating the mixed-venous oxygen tension

  13. Measurement of ventilation- and perfusion-mediated cooling during laser ablation in ex vivo human lung tumors

    Energy Technology Data Exchange (ETDEWEB)

    Vietze, Andrea, E-mail: anvie@gmx.de [Department of Diagnostic Radiology and Neuroradiology, Ernst-Moritz-Arndt-Universitaet Greifswald, Sauerbruchstrasse, 17487 Greifswald (Germany); Koch, Franziska, E-mail: franzi_koch@hotmail.com [Department of Diagnostic Radiology and Neuroradiology, Ernst-Moritz-Arndt-Universitaet Greifswald, Sauerbruchstrasse, 17487 Greifswald (Germany); Laskowski, Ulrich, E-mail: ulrich.laskowski@klinikum-luedenscheid.de [Department of Vascular and Thoracic Surgery, Klinikum Luedenscheid, Paulmannshoeher Strasse 14, 58515 Luedenscheid (Germany); Linder, Albert, E-mail: albert.linder@klinikum-bremen-ost.de [Department of Thoracic Surgery, Klinikum Bremen-Ost, Zuericher Strasse 40, 28325 Bremen (Germany); Hosten, Norbert, E-mail: hosten@uni-greifswald.de [Department of Diagnostic Radiology and Neuroradiology, Ernst-Moritz-Arndt-Universitaet Greifswald, Sauerbruchstrasse, 17487 Greifswald (Germany)

    2011-11-15

    Purpose: Perfusion-mediated tissue cooling has often been described in the literature for thermal ablation therapies of liver tumors. The objective of this study was to investigate the cooling effects of both perfusion and ventilation during laser ablation of lung malignancies. Materials and methods: An ex vivo lung model was used to maintain near physiological conditions for the specimens. Fourteen human lung lobes containing only primary lung tumors (non-small cell lung cancer) were used. Laser ablation was carried out using a Nd:YAG laser with a wavelength of 1064 nm and laser fibers with 30 mm diffusing tips. Continuous invasive temperature measurement in 10 mm distance from the laser fiber was performed. Laser power was increased at 2 W increments starting at 10 W up to a maximum power of 12-20 W until a temperature plateau around 60 deg. C was reached at one sensor. Ventilation and perfusion were discontinued for 6 min each to assess their effects on temperature development. Results: The experiments lead to 25 usable temperature profiles. A significant temperature increase was observed for both discontinued ventilation and perfusion. In 6 min without perfusion, the temperature rose about 5.5 deg. C (mean value, P < 0.05); without ventilation it increased about 7.0 deg. C (mean value, P < 0.05). Conclusion: Ventilation- and perfusion-mediated tissue cooling are significant influencing factors on temperature development during thermal ablation. They should be taken into account during the planning and preparation of minimally invasive lung tumor treatment in order to achieve complete ablation.

  14. Lung ventilation-perfusion imbalance in pulmonary emphysema. Assessment with automated V/Q quotient SPECT

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Koike, Hiroaki; Iwanaga, Hideyuki; Tokuda, Osamu; Okada, Munemasa; Matsunaga, Naofumi

    2010-01-01

    Tc-99m-Technegas-macro-aggregated albumin (MAA) single photon emission computed tomography (SPECT)-derived ventilation (V)/perfusion (Q) quotient SPECT was used to assess lung V-Q imbalance in patients with pulmonary emphysema. V/Q quotient SPECT and V/Q profile were automatically built in 38 patients with pulmonary emphysema and 12 controls, and V/Q distribution and V/Q profile parameters were compared. V/Q distribution on V/Q quotient SPECT was correlated with low attenuation areas (LAA) on density-mask computed tomography (CT). Parameters of V/Q profile such as the median, standard deviation (SD), kurtosis and skewness were proposed to objectively evaluate the severity of lung V-Q imbalance. In contrast to uniform V/Q distribution on V/Q quotient SPECT and a sharp peak with symmetrical V/Q distribution on V/Q profile in controls, lung areas showing heterogeneously high or low V/Q and flattened peaks with broadened V/Q distribution were frequently seen in patients with emphysema, including lung areas with only slight LAA. V/Q distribution was also often asymmetric regardless of symmetric LAA. All the proposed parameters of V/Q profile in entire lungs of patients with emphysema showed large variations compared with controls; SD and kurtosis were significantly different from controls (P<0.0001 and P<0.001, respectively), and a significant correlation was found between SD and A-aDO2 (P<0.0001). V/Q quotient SPECT appears to be more sensitive to detect emphysematous lungs compared with morphologic CT in patients with emphysema. SD and kurtosis of V/Q profile can be adequate parameters to assess the severity of lung V-Q imbalance causing gas-exchange impairment in patients with emphysema. (author)

  15. Computer program for regional assessment of lung perfusion defect. Part II - verification of the algorithm

    International Nuclear Information System (INIS)

    Stefaniak, B.

    2002-01-01

    As described earlier, a dedicated computer program was developed for quantitative evaluation of regional lung perfusion defects, visualized by pulmonary scintigraphy. The correctness of the basic assumptions accepted to construct the algorithms and of the all program functions needed to be checked, before application of the program into the clinical routine. The aim of this study was to verified the program using various software instruments and physical models. Evaluation of the proposed method was performed using software procedures, physical lung phantom, and selected lung image.The reproducibility of lung regions, defined by the program was found excellent. No significant distortion of registered data was observed after ROI transformation into the circle and retransformation into the original shape. The obtained results comprised parametric presentation of activity defects as well as a set of numerical indices which defined extent and intensity of decreased counts density. Among these indices PD2 and DM* were proved the most suitable for the above purposes. The obtained results indicate that the algorithms used for the program construction were correct and suitable for the aim of the study. The above algorithms enable function under study to be presented graphically with true imaging of activity distribution, as well as numerical indices, defining extent and intensity of activity defects to calculated. (author)

  16. Lung perfusion in hemorrhagic shock of rats. The effects of resuscitation with whole blood, saline or hes 6%

    Energy Technology Data Exchange (ETDEWEB)

    Turhanoglu, S.; Kaya, S.; Kararmaz, A.; Turhanoglu, A.D. [Dicle Univ., Diyarbakir (Turkey). Medical School

    2001-12-01

    This study was undertaken to determine the effects of various resuscitation regimens on lung perfusion following resuscitation from hemorrhagic shock. Fourty male Sprague-Dawley rats (250-300 g) were used. The rats were divided randomly into four groups (n=10 for each) and were sedated with intramuscular ketamine (100 mg/kg). We measured blood pressure, rectal temperature and lung perfusion using radioscintigraphy with a technetium colloid indicator. The systolic blood pressure was decreased 75% by removing blood via v. jugularis in the first three groups and group 4 was accepted as the control group, and blood volume was not diminished. Then the first three groups were resuscitated with autologous blood containing 125 units heparine/ml in group 1, saline in group 2, and hydroxyethyl starch (HES) 6% in group 3. After the correction of hypovolemia, all animals were injected 100 Bg (0.1 cc) technetium 99m macroaggregated albumin ({sup 99m}Tc MAA) via penil vein. After injection of {sup 99m}Tc MAA, 3 minutes fixed images were detected by a {gamma} camera in posterior position at 15 minutes and 5 hours. {sup 99m}Tc MMA ''wash out'' rate in lung was determined quantitatively at 5 hours. Compared to a control group, lung perfusion was decreased significantly in groups resuscitated with saline, and HES 6% while perfusion was restored with autologous blood. We conclude that heparinized autologous blood saved lung capillary circulation in hemorrhagic shock in rats. (author)

  17. Lung perfusion in hemorrhagic shock of rats. The effects of resuscitation with whole blood, saline or hes 6%

    International Nuclear Information System (INIS)

    Turhanoglu, S.; Kaya, S.; Kararmaz, A.; Turhanoglu, A.D.

    2001-01-01

    This study was undertaken to determine the effects of various resuscitation regimens on lung perfusion following resuscitation from hemorrhagic shock. Fourty male Sprague-Dawley rats (250-300 g) were used. The rats were divided randomly into four groups (n=10 for each) and were sedated with intramuscular ketamine (100 mg/kg). We measured blood pressure, rectal temperature and lung perfusion using radioscintigraphy with a technetium colloid indicator. The systolic blood pressure was decreased 75% by removing blood via v. jugularis in the first three groups and group 4 was accepted as the control group, and blood volume was not diminished. Then the first three groups were resuscitated with autologous blood containing 125 units heparine/ml in group 1, saline in group 2, and hydroxyethyl starch (HES) 6% in group 3. After the correction of hypovolemia, all animals were injected 100 Bg (0.1 cc) technetium 99m macroaggregated albumin ( 99m Tc MAA) via penil vein. After injection of 99m Tc MAA, 3 minutes fixed images were detected by a γ camera in posterior position at 15 minutes and 5 hours. 99m Tc MMA ''wash out'' rate in lung was determined quantitatively at 5 hours. Compared to a control group, lung perfusion was decreased significantly in groups resuscitated with saline, and HES 6% while perfusion was restored with autologous blood. We conclude that heparinized autologous blood saved lung capillary circulation in hemorrhagic shock in rats. (author)

  18. Lung ventilation-perfusion imbalance in pulmonary emphysema: assessment with automated V/Q quotient SPECT.

    Science.gov (United States)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Koike, Hiroaki; Iwanaga, Hideyuki; Tokuda, Osamu; Okada, Munemasa; Matsunaga, Naofumi

    2010-05-01

    Tc-99m-Technegas-MAA single photon emission computed tomography (SPECT)-derived ventilation (V)/perfusion (Q) quotient SPECT was used to assess lung V-Q imbalance in patients with pulmonary emphysema. V/Q quotient SPECT and V/Q profile were automatically built in 38 patients with pulmonary emphysema and 12 controls, and V/Q distribution and V/Q profile parameters were compared. V/Q distribution on V/Q quotient SPECT was correlated with low attenuation areas (LAA) on density-mask computed tomography (CT). Parameters of V/Q profile such as the median, standard deviation (SD), kurtosis and skewness were proposed to objectively evaluate the severity of lung V-Q imbalance. In contrast to uniform V/Q distribution on V/Q quotient SPECT and a sharp peak with symmetrical V/Q distribution on V/Q profile in controls, lung areas showing heterogeneously high or low V/Q and flattened peaks with broadened V/Q distribution were frequently seen in patients with emphysema, including lung areas with only slight LAA. V/Q distribution was also often asymmetric regardless of symmetric LAA. All the proposed parameters of V/Q profile in entire lungs of patients with emphysema showed large variations compared with controls; SD and kurtosis were significantly different from controls (P emphysema. SD and kurtosis of V/Q profile can be adequate parameters to assess the severity of lung V-Q imbalance causing gas-exchange impairment in patients with emphysema.

  19. Endothelin receptors and activity differ in human, dog, and rabbit lung.

    Science.gov (United States)

    McKay, K O; Armour, C L; Black, J L

    1996-01-01

    In this study, we have examined dog and rabbit airways as potential models for human airways in regard to the activity of endothelin. The receptors involved in the response to endothelin-1 (ET-1) in airway tissue from human, rabbit, and dog lung were investigated, as was the mechanism responsible for the contraction to ET-1 in tissue from the three species. By using specific endothelin receptor agonists and antagonists, we have demonstrated that ETB receptors predominate in rabbit and human airways and ETA receptors in dog airways. The contraction to ET-1 is not dependent on cyclooxygenase products of arachidonic acid, as indomethacin had no effect on the response to ET-1. Extracellular calcium influx via voltage-dependent channels is necessary for contraction to ET-1 in rabbit and dog airways. These results are in contrast to our previously reported results in human airways, in which neither removal of extracellular calcium nor verapamil affected the ET-1 response. The sustained phase of the contraction to ET-1 in all three species may be mediated in part by activation of protein kinase C (PKC), as the inhibitor staurosporine significantly altered the time course of the response to endothelin. We therefore conclude that in rabbit airways ET-1 activates ETB receptors, triggers the influx of extracellular calcium through voltage-dependent channels, and induces a contractile response that is, in part, dependent upon stimulation of PKC. The same mechanism is triggered in dog bronchus; however, the receptors involved in this species are of the ETA type. Finally, in human airways, the contractile response to ET-1, while independent of extracellular calcium influx, is dependent upon PKC activation after binding of the peptide to ETB receptors.

  20. Pulmonary NO and C18O2 uptake during pressure-induced lung expansion in rabbits.

    Science.gov (United States)

    Heller, Hartmut; Schuster, Klaus-Dieter

    2007-01-01

    In artificially ventilated animals we investigated the dependence of the pulmonary diffusing capacities of nitric oxide (NO) and doubly 18O-labeled carbon dioxide (DLNO, DLC18O2) on lung expansion with respect to ventilator-driven increases in intrapulmonary pressure. For this purpose we applied computerized single-breath experiments to 11 anesthetized paralyzed rabbits (weight 2.8-3.8 kg) at various alveolar volumes (45-72 ml) by studying the almost entire inspiratory limb of the respective pressure/volume curves (intrapulmonary pressure: 6-27 cmH2O). The animals were ventilated with room air, employing a computerized ventilatory servo-system that we designed to maintain mechanical ventilation and to execute the particular lung function tests automatically. Each single-breath maneuver was started from residual volume (13.5+/-2 ml, mean+/-SD) by inflating the rabbit lungs with 35-55 ml indicator gas mixture containing 0.05% NO in N2 or 0.9% C18O2 in N2. Alveolar partial pressures of NO and C18O2 were measured by respiratory mass spectrometry. Values of DLNO and DLC18O2 ranged between 1.55 and 2.49 ml/(mmHg min) and 11.7 and 16.6 ml/(mmHg min), respectively. Linear regression analyses yielded a significant increase in DLNO with simultaneous increase in alveolar volume (Pvolume on DLC18O2 values.

  1. Experimental study of lung perfusion scintigraphy with sup(99m)Tc-MAA to radiation damaged lung

    International Nuclear Information System (INIS)

    Harada, Tateki

    1976-01-01

    The histological changes including blood flow damage due to the irradiation were studied on the rabbits which received the fractionated irradiation of 60 Co from the standpoint of the correlationship with the nuclide concentration of the lesion. 1) The histological changes, such as edema, and the congestion in the alveolar wall, initiated right after the 4,000 R of 60 Co irradiation, and they become worse with the increase of irradiation dose and with passage of time. In the group of rabbits which was given 10,000 R of irradiation, the remarkable hyperplasia of the alveolar wall, and emphysema manifested, and the fibrosis of the stroma advanced remarkably. 2) X-ray examination revealed the abnormal shadow in the lung only in the group of 10,000 R irradiation right after the end of irradiation. 3) Digital scintigram revealed that in the groups of less than 8,000 R of irradiation blood flow damage recovered, on the other hand, in the group of 10,000 R irradiation, remarkable damage continued for 3 months. These results were assumed to correspond to the degree of abnormality of the histological findings, such as the hyperplasia of the alveolar wall and the blood vessels, emphysem, and fibrosis. 4) Digital scintigram which was processed with computer provided the clearer image of the degree and extent of blood flow damage than those of the original scintigram. (Mukohata, S.)

  2. Experimental study of lung perfusion scintigraphy with sup(99m)Tc-MAA in radiation damaged lung

    Energy Technology Data Exchange (ETDEWEB)

    Harada, T [Kurume Univ., Fukuoka (Japan). School of Medicine

    1976-11-01

    The histological changes including blood flow damage due to the irradiation were studied on the rabbits which received the fractionated irradiation of /sup 60/Co from the standpoint of the correlationship with the nuclide concentration of the lesion. 1) The histological changes, such as edema, and the congestion in the alveolar wall, initiated right after the 4,000 R of /sup 60/Co irradiation, and they become worse with the increase of irradiation dose and with passage of time. In the group of rabbits which was given 10,000 R of irradiation, the remarkable hyperplasia of the alveolar wall, and emphysemaa manifested, and the fibrosis of the stroma advanced remarkably. 2) X-ray examination revealed the abnormal shadow in the lung only in the group of 10,000 R irradiation right after the end of irradiation. 3) Digital scintigram revealed that in the groups of less than 8,000 R of irradiation blood flow damage recovered, on the other hand, in the group of 10,000 R irradiation, remarkable damage continued for 3 months. These results were assumed to correspond to the degree of abnormality of the histological findings, such as the hyperplasia of the alveolar wall and the blood vessels, emphysem, and fibrosis. 4) Digital scintigram which was processed with computer provided the clearer image of the degree and extent of blood flow damage than those of the original scintigram.

  3. Low pulmonary artery flush perfusion pressure combined with high positive end-expiratory pressure reduces oedema formation in isolated porcine lungs

    International Nuclear Information System (INIS)

    Schumann, Stefan; Schließmann, Stephan J; Wagner, Giskard; Goebel, Ulrich; Priebe, Hans-Joachim; Guttmann, Josef; Kirschbaum, Andreas

    2010-01-01

    Flush perfusion of the pulmonary artery with organ protection solution is a standard procedure before lung explantation. However, rapid flush perfusion may cause pulmonary oedema which is deleterious in the lung transplantation setting. In this study we tested the hypotheses that high pulmonary perfusion pressure contributes to the development of pulmonary oedema and positive end-expiratory pressure (PEEP) counteracts oedema formation. We expected oedema formation to increase weight and decrease compliance of the lungs on the basis of a decrease in alveolar volume as fluid replaces alveolar air spaces. The pulmonary artery of 28 isolated porcine lungs was perfused with a low-potassium dextrane solution at low (mean 27 mmHg) or high (mean 40 mmHg) pulmonary artery pressure (PAP) during mechanical ventilation at low (4 cmH 2 O) or high (8 cmH 2 O) PEEP, respectively. Following perfusion and storage, relative increases in lung weight were smaller (p < 0.05) during perfusion at low PAP (62 ± 32% and 42 ± 26%, respectively) compared to perfusion at high PAP (133 ± 54% and 87 ± 30%, respectively). Compared to all other PAP–PEEP combinations, increases in lung weight were smallest (44 ± 9% and 27 ± 12%, respectively), nonlinear intratidal lung compliance was largest (46% and 17% respectively, both p < 0.05) and lung histology showed least infiltration of mononuclear cells in the alveolar septa, and least alveolar destruction during the combination of low perfusion pressure and high PEEP. The findings suggest that oedema formation during pulmonary artery flush perfusion in isolated and ventilated lungs can be reduced by choosing low perfusion pressure and high PEEP. PAP–PEEP titration to minimize pulmonary oedema should be based on lung mechanics and PAP monitoring

  4. Prediction of postoperative pulmonary function using 99mTc-MAA perfusion lung SPECT

    International Nuclear Information System (INIS)

    Hosokawa, Nobuyuki; Tanabe, Masatada; Satoh, Katashi; Takashima, Hitoshi; Ohkawa, Motoomi; Maeda, Masazumi; Tamai, Toyosato; Kojima, Kanji.

    1995-01-01

    In order to predict postoperative pulmonary function, 99m Tc-MAA perfusion lung SPECT and spirometry were performed preoperatively in 52 patients with resectable primary lung cancer; 44 underwent lobectomy, eight pneumonectomy. Local pulmonary function (called local effective volume) was evaluated according to the degree of radionuclide distribution of each voxel in the SPECT images. The total effective volume was defined as the sum of the local effective volume, and the residual effective volume was the total effective volume excluding loss after operation. Predicted pulmonary function (VC and FEV 1.0) was calculated by the following formula: Predicted value=preoperative value x percent of the residual effective volume. Postoperative pulmonary function was predicted in the same patients by means of 99m Tc-MAA perfusion lung planar scintigraphy and X-ray CT. The patients were reinvestigated with spirometry at one and four months after surgery, and the values were compared with the predicted values. The correlations between the predicted values using SPECT and measured postoperative pulmonary function were highly significant (VC: r=0.867, FEV1.0: r=0.864 one month after operation; VC: r=0.860, FEV1.0: r=0.907 4 months after operation). The predicted values calculated using SPECT were accurate compared with the predicted values calculated using planar scintigraphy or X-ray CT. The patients with predicted FEV1.0 of less than 0.8 liter required home oxygen therapy. This method is valuable for the prediction of postoperative pulmonary function before the surgical procedure. (author)

  5. Intracellular calcium and the mechanism of anodal supernormal excitability in langendorff perfused rabbit ventricles.

    Science.gov (United States)

    Joung, Boyoung; Park, Hyung-Wook; Maruyama, Mitsunori; Tang, Liang; Song, Juan; Han, Seongwook; Piccirillo, Gianfranco; Weiss, James N; Lin, Shien-Fong; Chen, Peng-Sheng

    2011-01-01

    Anodal stimulation hyperpolarizes the cell membrane and increases the intracellular Ca(2+) (Ca(i)) transient. This study tested the hypothesis that the maximum slope of the Ca(i) decline (-(dCa(i)/dt)(max)) corresponds to the timing of anodal dip on the strength-interval curve and the initiation of repetitive responses and ventricular fibrillation (VF) after a premature stimulus (S(2)). We simultaneously mapped the membrane potential (V(m)) and Ca(i) in 23 rabbit ventricles. A dip in the anodal strength-interval curve was observed. During the anodal dip, ventricles were captured by anodal break excitation directly under the S(2) electrode. The Ca(i) following anodal stimuli is larger than that following cathodal stimuli. The S(1)-S(2) intervals of the anodal dip (203±10 ms) coincided with the -(dCa(i)/dt)(max) (199±10 ms, P=NS). BAPTA-AM (n=3), inhibition of the electrogenic Na(+)-Ca(2+) exchanger current (I(NCX)) by low extracellular Na(+) (n=3), and combined ryanodine and thapsigargin infusion (n=2) eliminated the anodal supernormality. Strong S(2) during the relative refractory period (n=5) induced 29 repetitive responses and 10 VF episodes. The interval between S(2) and the first non-driven beat was coincidental with the time of -(dCa(i)/dt)(max). Larger Ca(i) transient and I(NCX) activation induced by anodal stimulation produces anodal supernormality. The time of maximum I(NCX) activation is coincidental to the induction of non-driven beats from the Ca(i) sinkhole after a strong premature stimulation. All rights are reserved to the Japanese Circulation Society.

  6. Evaluation of femoral perfusion in a rabbit model of steroid-induced osteonecrosis by dynamic contrast-enhanced MRI with a high magnetic field MRI system.

    Science.gov (United States)

    Hayashi, Shigeki; Fujioka, Mikihiro; Ikoma, Kazuya; Saito, Masazumi; Ueshima, Keiichiro; Ishida, Masashi; Kuribayashi, Masaaki; Ikegami, Akira; Mazda, Osam; Kubo, Toshikazu

    2015-04-01

    To evaluate perfusion during the early phase after steroid administration in vivo using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) with a high magnetic field MRI system. The main pathogenesis of steroid-induced osteonecrosis is considered to be ischemia. A single dose of methylprednisolone (MPSL) was injected into nine rabbits. DCE-MRI was performed for these rabbits before MPSL administration and 1, 5, 10, and 14 days after administration. Time-signal intensity curves were created for each femur based on the signal intensity to evaluate perfusion. Enhancement ratio (ER), initial slope (IS), and area under the curve (AUC) were calculated and the value before MPSL administration and the minimal value after administration were compared statistically. ER, IS, and AUC values after MPSL administration significantly decreased (P < 0.05, P < 0.01, and P < 0.01, respectively). All of them decreased by the 5th day in 56% of the femora and by the 14th day in 83%, and some femora even showed a decrease from the 1st day. In this study, decreased perfusion in the femora after steroid administration was proven. Additionally, we could show that it occurred from the early days after steroid administration. © 2014 Wiley Periodicals, Inc.

  7. Automatic delineation of functional lung volumes with 68Ga-ventilation/perfusion PET/CT.

    Science.gov (United States)

    Le Roux, Pierre-Yves; Siva, Shankar; Callahan, Jason; Claudic, Yannis; Bourhis, David; Steinfort, Daniel P; Hicks, Rodney J; Hofman, Michael S

    2017-10-10

    Functional volumes computed from 68 Ga-ventilation/perfusion (V/Q) PET/CT, which we have shown to correlate with pulmonary function test parameters (PFTs), have potential diagnostic utility in a variety of clinical applications, including radiotherapy planning. An automatic segmentation method would facilitate delineation of such volumes. The aim of this study was to develop an automated threshold-based approach to delineate functional volumes that best correlates with manual delineation. Thirty lung cancer patients undergoing both V/Q PET/CT and PFTs were analyzed. Images were acquired following inhalation of Galligas and, subsequently, intravenous administration of 68 Ga-macroaggreted-albumin (MAA). Using visually defined manual contours as the reference standard, various cutoff values, expressed as a percentage of the maximal pixel value, were applied. The average volume difference and Dice similarity coefficient (DSC) were calculated, measuring the similarity of the automatic segmentation and the reference standard. Pearson's correlation was also calculated to compare automated volumes with manual volumes, and automated volumes optimized to PFT indices. For ventilation volumes, mean volume difference was lowest (- 0.4%) using a 15%max threshold with Pearson's coefficient of 0.71. Applying this cutoff, median DSC was 0.93 (0.87-0.95). Nevertheless, limits of agreement in volume differences were large (- 31.0 and 30.2%) with differences ranging from - 40.4 to + 33.0%. For perfusion volumes, mean volume difference was lowest and Pearson's coefficient was highest using a 15%max threshold (3.3% and 0.81, respectively). Applying this cutoff, median DSC was 0.93 (0.88-0.93). Nevertheless, limits of agreement were again large (- 21.1 and 27.8%) with volume differences ranging from - 18.6 to + 35.5%. Using the 15%max threshold, moderate correlation was demonstrated with FEV1/FVC (r = 0.48 and r = 0.46 for ventilation and perfusion images, respectively

  8. Comparative analysis of radionuclide inhalation and perfusion lung imaging with X ray pulmonary angiography for the diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Zhang Yanyan; Chen Man; Shao Maogang; Zhang Songlin; Mao Jieming; Guo Jingxuan

    1993-01-01

    The result of radionuclide lung imaging was compared in 18 patients of pulmonary embolism (PE) and 2 normal persons. The discovered perfusion defects correlated well with the location of angiographic obstruction. The positive angiographic and radionuclide finding was in 141 and 104 emboli arteries respectively. The sensitivity of total emboli pulmonary segments of lung imaging was 73.8%, the specificity was 82.7 and the accuracy was 79%. The techniques correlated quite well (r = 0.83, P<0.001)

  9. A porcine ex vivo lung perfusion model with maximal argon exposure to attenuate ischemia-reperfusion injury

    Directory of Open Access Journals (Sweden)

    An Martens

    2017-01-01

    Full Text Available Argon (Ar is a noble gas with known organoprotective effects in rodents and in vitro models. In a previous study we failed to find a postconditioning effect of Ar during ex vivo lung perfusion (EVLP on warm-ischemic injury in a porcine model. In this study, we further investigated a prolonged exposure to Ar to decrease cold ischemia-reperfusion injury after lung transplantation in a porcine model with EVLP assessment. Domestic pigs (n = 6/group were pre-conditioned for 6 hours with 21% O 2 and 79% N 2 (CONTR or 79% Ar (ARG. Subsequently, lungs were cold flushed and stored inflated on ice for 18 hours inflated with the same gas mixtures. Next, lungs were perfused for 4 hours on EVLP (acellular while ventilated with 12% O 2 and 88% N 2 (CONTR group or 88% Ar (ARG group. The perfusate was saturated with the same gas mixture but with the addition of CO 2 to an end-tidal CO 2 of 35-45 mmHg. The saturated perfusate was drained and lungs were perfused with whole blood for an additional 2 hours on EVLP. Evaluation at the end of EVLP did not show significant effects on physiologic parameters by prolonged exposure to Ar. Also wet-to-dry weight ratio did not improve in the ARG group. Although in other organ systems protective effects of Ar have been shown, we did not detect beneficial effects of a high concentration of Ar on cold pulmonary ischemia-reperfusion injury in a porcine lung model after prolonged exposure to Ar in this porcine model with EVLP assessment.

  10. The matching of ventilation and perfusion in the lung of the Tegu lizard, Tupinambis nigropunctatus.

    Science.gov (United States)

    Hlastala, M P; Standaert, T A; Pierson, D J; Luchtel, D L

    1985-06-01

    Ventilation-perfusion (VA/Q) distribution was evaluated in the Tegu lizard, Tupinambis nigropunctatus, using the multiple inert gas elimination technique (MIGET) in order to define the limitations to gas exchange in the large chambered unicameral lung. The lizards (0.52-1.1 kg) were anesthetized with halothane and ventilated. Body temperature was maintained at 35 degrees C. Arterial and sinus venosus PO2 averaged 79.4 +/- 5.9 and 47.3 +/- 6.4 torr while breathing air and 232.1 +/- 31 and 64.8 +/- 11.5 torr while breathing oxygen. VA/Q distributions were broad and right-to-left shunt averaged 21% while breathing air and 27% while breathing oxygen. Gas exchange was significantly impaired due to the presence of both shunt and VA/Q heterogeneity. The walls of the lung enclose a large axial air chamber. Microscopic examination revealed approximately three generations of septa which subdivided the wall into tubular-shaped gas-exchange chambers. Wall thickness averages 2.8 mm at the anterior end of the lung, 2.1 mm in the middle portion of the lung and 1.4 mm at the posterior end. The thickness of the blood-air barrier (epithelial-basal lamina-endothelial cell layer) ranged from 0.35 to 0.90 micron. Although this barrier is slightly thicker than in the mammalian lung (0.1-0.5 micron), it is unlikely to be a source of diffusion limitation in gas exchange at rest.

  11. Isolated lung perfusion with gemcitabine for the treatment of pulmonary metastases : Experimental study in a rat model

    NARCIS (Netherlands)

    Putte, B.P. van

    2003-01-01

    Isolated lung perfusion is an experimental surgical technique for the treatment of pulmonary metastases in order to improve the current 5-year survival of approximately 40 % after surgical resection of manually palpable metastases. Several drugs have been tested in animals models and five phase I

  12. Neutrophil elastase inhibitor, ONO-5046, modulates acid-induced lung and systemic injury in rabbits.

    Science.gov (United States)

    Kaneko, K; Kudoh, I; Hattori, S; Yamada, H; Ohara, M; Wiener-Kronish, J; Okumura, F

    1997-09-01

    Acid instillation leads to direct lung and to secondary systemic organ injury, probably via activated macrophages and neutrophils. This study investigated the effects of neutrophil elastase on organ injury after unilateral lung acid instillation by administrating a specific neutrophil elastase inhibitor, ONO-5046, before acid instillation. Three groups of anesthetized rabbits (n = 12 in each group) underwent tracheostomies, and instillations were made into their right lower lobe airspaces with either phosphate buffered saline (pH, 7.4; volume, 1.2 ml/kg; n = 12) or HCl (pH, 1.25; volume, 1.2 ml/kg; n = 24). In half of the acid-instilled rabbits, ONO-5046, 10 mg/kg, was given intravenously 15 min before the HCl instillation, and then 10 mg x kg(-1) x h(-1) of the drug was continuously infused throughout the experiment. The other groups of animals received the vehicle intravenously. Anesthesia and mechanical ventilation was continued for 8 h, whereas arterial blood gases were sampled intermittently. Eight hours after saline or acid instillation, the animals were killed, and their lungs, heart, kidneys, liver, and small intestines were harvested. Wet-to-dry weight ratios (W/ D) and myeloperoxidase (MPO) assays of these organs were done, and elastase assays on the bronchoalveolar lavage fluids (BALF) obtained from each lung also were performed. Pretreatment with ONO-5046 attenuated the physiologic changes seen in the vehicle-treated animals. Significant decreases in W/D of the noninstilled lungs and of the small intestine and normalization of the oxygenation of the experimental animals occurred. The ONO-5046 pretreatment did not affect the neutrophil sequestration in the lungs or in the other organs as determined by neutrophil counts in BALF and by the MPO assays. A neutrophil elastase inhibitor, ONO-5046, administered immediately before acid instillation attenuated the physiologic changes seen in the vehicle-treated animals. The drug blocked neutrophil elastase but

  13. Cyclooxygenase-2-dependent bronchoconstriction in perfused rat lungs exposed to endotoxin.

    Science.gov (United States)

    Uhlig, S; Nüsing, R; von Bethmann, A; Featherstone, R L; Klein, T; Brasch, F; Müller, K M; Ullrich, V; Wendel, A

    1996-05-01

    Lipopolysaccharides (LPS), widely used to study the mechanisms of gram-negative sepsis, increase airway resistance by constriction of terminal bronchioles. The role of the cyclooxygenase (COX) isoenzymes and their prostanoid metabolites in this process was studied. Pulmonary resistance, the release of thromboxane (TX) and the expression of COX-2 mRNA were measured in isolated blood-free perfused rat lungs exposed to LPS. LPS induced the release of TX and caused increased airway resistance after about 30 min. Both TX formation and LPS-induced bronchoconstriction were prevented by treatment with the unspecific COX inhibitor acetyl salicylic acid, the specific COX-2 inhibitor CGP-28238, dexamethasone, actinomycin D, or cycloheximide. LPS-induced bronchoconstriction was also inhibited by the TX receptor antagonist BM-13177. The TX-mimetic compound, U-46619, increased airway resistance predominantly by constricting terminal bronchioles. COX-2-specific mRNA in lung tissue was elevated after LPS exposure, and this increase was attenuated by addition of dexamethasone or of actinomycin D. In contrast to LPS, platelet-activating factor (PAF) induced immediate TX release and bronchoconstriction that was prevented by acetyl salicylic acid, but not by CGP-28238. LPS elicits the following biochemical and functional changes in rat lungs: (i) induction of COX-2; (ii) formation of prostaglandins and TX; (iii) activation of the TX receptor on airway smooth muscle cells; (iv) constriction of terminal bronchioles; and (v) increased airway resistance. In contrast to LPS, the PAF-induced TX release is likely to depend on COX-1.

  14. Relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism: assessment with breath-hold SPECT-CT pulmonary angiography fusion images.

    Science.gov (United States)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Tokuda, Osamu; Matsunaga, Naofumi

    2008-09-01

    The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.

  15. Quantitative Xe-133 perfusion and exhalation scintigraphy of lungs in children with asthma

    International Nuclear Information System (INIS)

    Lederer, A.G.; Sternthal, H.M.; Nicoletti, R.; Fuger, G.F.

    1990-01-01

    In children with asthma, the authors quantified the extent of the obstructive lung disease by calculating a time to peak (TTP) and mean transit time (MTT) image. In this paper compare the results to common pulmonary function tests. The authors studied 17 children twice: first, after the initial intravenous therapy after an asthmatic attach and, second, before discharge from the hospital. After intravenous injection of 185-370 MBq of Xe-133, a dynamic computer acquisition was performed, and a TTP and MTT image were calculated. The authors were able to estimate the extent, intensity (qualified by the MTT), and location of the ventilation disorder as well as the changes of perfusion (expressed by the TTP) in sever disease

  16. Sildenafil improves blood perfusion in steroid-induced avascular necrosis of femoral head in rabbits via a protein kinase G-dependent mechanism.

    Science.gov (United States)

    Song, Qichun; Ni, Jianlong; Jiang, Hongyuan; Shi, Zhibin

    2017-10-01

    The aim of the study were to evaluate the effect of sildenafil against avascular necrosis of femoral head (ANFH) in a rabbit model, and to study the role of protein kinase G (PKG) pathway and vascular endothelial growth factor (VEGF) in ANFH. Three weeks after inducing ANFH with methylprednisolone injection, 45 female adult New Zealand white rabbits were divided into three groups and treated as follows: group SI received daily intraperitoneal sildenafil with a dose of 10 mg/kg per day; group SD received daily sildenafil identically to group SI plus auricular vein injection DT3 (a specific PKG inhibitor); group NS received only normal saline. The blood perfusion function in the femoral head was measured by perfusion MRI and ink artery infusion. Bilateral femora heads were examined histopathologically for the presence of osteonecrosis; VEGF of tissue was examined by Western blot analysis; cGMP level and PKG activity were also measured. The incidence of ANFH in SI group was significantly lower than that observed in NS and SD groups (p < 0.05). VEGF in SI group was increased compared to NS group. cGMP level and PKG activity were also significantly different between NS and SI group (p < 0.05). However, these effects of sildenafil in SD group were all markedly inhibited by the administration of DT3 compared to SI group. Sildenafil appear to increase the perfusion of femoral head by up-regulating VEGF through PKG pathway. The increased perfusion of femoral head could prevent ANFH. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  17. Pulmonary vascular volume ratio measured by cardiac computed tomography in children and young adults with congenital heart disease: comparison with lung perfusion scintigraphy.

    Science.gov (United States)

    Goo, Hyun Woo; Park, Sang Hyub

    2017-11-01

    Lung perfusion scintigraphy is regarded as the gold standard for evaluating differential lung perfusion ratio in congenital heart disease. To compare cardiac CT with lung perfusion scintigraphy for estimated pulmonary vascular volume ratio in patients with congenital heart disease. We included 52 children and young adults (median age 4 years, range 2 months to 28 years; 31 males) with congenital heart disease who underwent cardiac CT and lung perfusion scintigraphy without an interim surgical or transcatheter intervention and within 1 year. We calculated the right and left pulmonary vascular volumes using threshold-based CT volumetry. Then we compared right pulmonary vascular volume percentages at cardiac CT with right lung perfusion percentages at lung perfusion scintigraphy by using paired t-test and Bland-Altman analysis. The right pulmonary vascular volume percentages at cardiac CT (66.3 ± 14.0%) were significantly smaller than the right lung perfusion percentages at lung perfusion scintigraphy (69.1 ± 15.0%; P=0.001). Bland-Altman analysis showed a mean difference of -2.8 ± 5.8% and 95% limits of agreement (-14.1%, 8.5%) between these two variables. Cardiac CT, in a single examination, can offer pulmonary vascular volume ratio in addition to pulmonary artery anatomy essential for evaluating peripheral pulmonary artery stenosis in patients with congenital heart disease. However there is a wide range of agreement between cardiac CT and lung perfusion scintigraphy.

  18. Pathological changes in the rabbit lungs after irradiation and after combined irradiation and hyperthermia

    International Nuclear Information System (INIS)

    Zinner, M.

    1984-01-01

    The effects of combined irradiation and hyperthermia and of irradiation alone on normal lung tissue was investigated in rabbits. The animals of both therapy groups were irradiated with 2 Gy five times a week for a 6-week period. The animals of group 1 were additionally exposed to hyperthermia 3 times a week after irradiation. The method applied was the condenser field method (25 to 35 Watt/min). Only the right lung was treated in all animals. The animals were sacrificed 3 months after termination of the therapy, and large-surface lung sections were prepared. The following results were obtained: There is a quantifiable difference in the severeness of fibrosis between groups 1 and 2. Fibrosis was more pronounced in group 1 but the difference was not statistically significant. In both groups, fibrosis was unevenly distributed in the different lung areas. Fibrosis was highest in the ventral and apical regions. These were the regions where the highest local temperature rise was recorded during hyperthermia and where the highest local radiation dose was applied. Histologically, signs of acute inflammatory processes were observed in both groups in parallel to regeneration and repair processes involving neogenesis. (orig./MG) [de

  19. Functional mechanism of lung mosaic CT attenuation: assessment with deep-inspiration breath-hold perfusion SPECT-CT fusion imaging and non-breath-hold Technegas SPECT.

    Science.gov (United States)

    Suga, K; Yasuhiko, K; Iwanaga, H; Tokuda, O; Matsunaga, N

    2009-01-01

    The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Although further validation is required, our results indicate that heterogeneous pulmonary arterial

  20. High-frequency percussive ventilation attenuates lung injury in a rabbit model of gastric juice aspiration.

    Science.gov (United States)

    Allardet-Servent, Jérôme; Bregeon, Fabienne; Delpierre, Stéphane; Steinberg, Jean-Guillaume; Payan, Marie-José; Ravailhe, Sylvie; Papazian, Laurent

    2008-01-01

    To test the effects of high-frequency percussive ventilation (HFPV) compared with high-frequency oscillatory ventilation (HFOV) and low-volume conventional mechanical ventilation (LVCMV), on lung injury course in a gastric juice aspiration model. Prospective, randomized, controlled, in-vivo animal study. University animal research laboratory. Forty-three New Zealand rabbits. Lung injury was induced by intratracheal instillation of human gastric juice in order to achieve profound hypoxaemia (PaO2/FIO2ventilated for 4h after randomization in one of the following four groups: HFPV (median pressure 15cmH2O); LVCMV (VT 6mlkg(-1) and PEEP set to reach 15cmH2O plateau pressure); HFOV (mean pressure 15cmH2O); and a high-volume control group HVCMV (VT 12ml kg(-1) and ZEEP). Static respiratory compliance increased after the ventilation period in the HFPV, LVMCV and HFOV groups, in contrast with the HVCMV group. PaO2/FIO2 improved similarly in the HFPV, LVCMV and HFOV groups, and remained lower in the HVCMV group than in the three others. Lung oedema, myeloperoxidase and histological lung injury score were higher in the HVCMV group, but not different among all others. Arterial lactate markedly increased after 4h of ventilation in the HVCMV group, while lower but similar levels were observed in the three other groups. HFPV, like HFOV and protective CMV, improves respiratory mechanics and oxygenation, and attenuates lung damage. The HFPV provides attractive lung protection, but further studies should confirm these results before introducing HFPV into the clinical arena.

  1. Lung perfusion analysis with dual energy CT in patients with suspected pulmonary embolism—Influence of window settings on the diagnosis of underlying pathologies of perfusion defects

    International Nuclear Information System (INIS)

    Bauer, Ralf W.; Kerl, J. Matthias; Weber, Eva; Weisser, Philipp; Korkusuz, Huedayi; Lehnert, Thomas; Jacobi, Volkmar; Vogl, Thomas J.

    2011-01-01

    Purpose: On lung perfusion analysis with dual energy CT (DECT) in patients with suspected pulmonary embolism (PE) commonly three patterns of perfusion defects (PD) are observed: wedge-shaped, circumscribed but not wedge-shaped, and patchy. We investigated the influence of different window settings on the identification of the underlying pathologies for these types of PD. Materials and methods: 3724 segments in 196 consecutive patients who underwent pulmonary DECT angiography for clinically suspected acute PE were analyzed. Iodine distribution in the lung parenchyma was calculated from the dual energy data and displayed as color map in axial, sagittal and coronal view. Afterwards, lung and angiography window were applied separately and assessed for pulmonary embolism and pathologies of the lung parenchyma. Results: 1420 segments in 141 patients showed PD, of which 276 were wedge-shaped, 287 circumscribed and 857 patchy. Circumscribed PD were associated in 99% with interstitial or alveolar fluid collections and in 1% with located bullae. Patchy PD were associated in 65% with emphysematous or fibrotic changes, in 38% with diffuse infiltrations or interstitial fluid collections and in 0.2% with PE. The underlying pathologies for wedge-shaped PD were in 78% PE, in 3% tumors compressing pulmonary arteries, in another 3% located bullae and in further 3% infiltrations. 13% (n = 15) of the segments in this group did not show vascular or parenchymal pathologies, but in 80% (n = 10) of these cases patients had PE in another segment. Totally n = 6 of wedge-shaped PD in 5 patients remained with unclear direct cause. Conclusion: Whereas patchy and circumscribed PD are almost exclusively associated with pathologies of the lung parenchyma, wedge-shaped PD are mostly associated with PE. For a small number of wedge-shaped PD the underlying cause cannot be detected with DECT. Very small peripherally situated micro-emboli may be discussed as a reason. However, prospective trials are

  2. An evaluation of the feasibility of assessment of volume perfusion for the whole lung by 128-slice spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Haitao [Imaging Center of Taian Central Hospital, Taian, Shandong (China); Gao, Fei; Li, Ning; Liu, Cheng [Shandong Univ., Shandong Medical Imaging Research Inst., CT Room, Shandong (China)], e-mail: liucheng491025@sina.com

    2013-10-15

    Background: Lung perfusion based on dynamic scanning cannot provide a quantitative assessment of the whole lung because of the limited coverage of the current computed tomography (CT) detector designs. Purpose: To evaluate the feasibility of dynamic volume perfusion CT (VPCT) of the whole lung using a 128-slice CT for the quantitative assessment and visualization of pulmonary perfusion. Material and Methods: Imaging was performed in a control group of 17 subjects who had no signs of disturbance of pulmonary function or diffuse lung disease, and 15 patients (five patients with acute pulmonary embolism and 10 with emphysema) who constituted the abnormal lung group. Dynamic VPCT was performed in all subjects, and pulmonary blood flow (PBF), pulmonary blood volume (PBV), and mean transit time (MTT) were calculated from dynamic contrast images with a coverage of 20.7 cm. Regional and volumetric PBF, PBV, and MTT were statistically evaluated and comparisons were made between the normal and abnormal lung groups. Results: Regional PBF (94.2{+-}36.5, 161.8 {+-}29.6, 185.7 {+-}38.1 and 125.5 {+-}46.1, 161.9 {+-}31.4, 169.3 {+-}51.7), PBV (6.7 {+-}2.8, 10.9 {+-}3.0, 12.9 {+-}4.5 and 9.9 {+-}4.6, 10.3 {+-}2.9, 11.9 {+-}4.5), and MTT (5.8 {+-}2.4, 4.5 {+-}1.3, 4.7 {+-}2.1 and 5.6 {+-}2.3, 4.3 {+-}1.5, 4.9 {+-}1.5) demonstrated significant differences in the gravitational and isogravitational directions in the normal lung group (P < 0.05). The PBF (154.2 {+-}30.6 vs. 94.9 {+-}15.9) and PBV (11.1 {+-}4.0 vs. 6.6 {+-}1.7) by dynamic VPCT showed significant differences between normal and abnormal lungs (P < 0.05), notwithstanding the four large lungs that had coverage > 20.7 cm. Conclusion: Dynamic VPCT of the whole lung is feasible for the quantitative assessment of pulmonary perfusion by 128-slice CT, and may in future permit the evaluation of both morphological and functional features of the whole lung in a single examination.

  3. Regional measurement of ventilation and perfusion to detect subtle lung abnormalities in coal miners

    International Nuclear Information System (INIS)

    Susskind, H.; Liu, J.; Brill, A.B.

    1986-01-01

    The relationship between regional pulmonary ventilation (V) and perfusion (Q) uniquely determines the amount of gas exchange that occurs in the lungs. Therefore, the pixel-by-pixel distributions of V and Q were measured with continuously inhaled Kr-81m and i.v. injected Tc-99m MAA, respectively, in a group of 71 subjects exposed to coal dust and then compared with those from a control group of 9 healthy volunteers. Each subject sat upright with his back against a large-field-of-view scintillation camera; 500,000 count images were obtained, analyzed by computer, and then displayed in a 64 x 64 matrix. Individual pixel values of V and Q were correlated by a best-fit regression line, whose slope was proportional to the overall V/Q ratio. The slopes of individual groups of nonsmokers, ex-smokers, and smokers (0.83-0.85) were significantly greater (p < 0.02) than the slope of the controls (0.70 +/- 0.07). In addition, the authors found that the skewness of plots of frequency distribution of V/Q and of V and Q vs V/Q for the individual patient groups was statistically different from that of the normals (p < 0.01). Statistical analysis of local and Q values therefore appears to be a potentially useful, non-invasive method to evaluate subtle regional lung impairment

  4. Factors affecting the lung perfused blood volume in patients with intrapulmonary clots after anti-coagulation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa, E-mail: radokada@yamaguchi-u.ac.jp [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Masuda, Yu [4th Grade of 6-year Medicine Doctor Program, Department of Medicine, Yamaguchi University Faculty of Medicine and Health Sciences 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Nakashima, Yoshiteru [Department of Radiology, Yamaguchi Grand Medical Center, Oosaki 77, Hofu, Yamaguchi 747-8511 (Japan); Nomura, Takafumi; Nakao, Sei [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan); Suga, Kazuyoshi [Department of Radiology, St Hills Hospital, Imamurakita 3-7-18, Ube, Yamaguchi 755-0155 (Japan); Kido, Shoji [Computer-aided Diagnosis and Biomedical Imaging Research Biomedical Engineering, Applied Medical Engineering Science Graduate School of Medicine, Yamaguchi University, Tokiwadai 2-16-1, Ube, Yamaguchi 755-8611 (Japan); Matsunaga, Naofumi [Department of Radiology, Yamaguchi University Graduate School of Medicine 1-1-1 Minamikogushi, Ube, Yamaguchi 755-8505 (Japan)

    2015-08-15

    Highlights: • Dual-energy CT can provide morphological and functional lung images in the same examination. • The subsequent dual-energy CT demonstrates the increased whole lung perfused blood volume (V{sub 120}) despite the residual intrapulmonary clots after treatment in one examination. • The increased whole lung perfusion (V{sub 120}) and a decreased low perfusion volume (V{sub 5}) result in the improvement in the low perfusion rate (%V{sub 5}) in the patients with acute pulmonary embolism after treatment. - Abstract: Objectives: Factors affecting the improvement in the lung perfused blood volume (LPBV) were evaluated based on the presence of intrapulmonary clots (IPCs) after anti-coagulation therapy using 64-slice dual-energy CT. Materials and methods: 96 patients exhibiting venous thromboembolism underwent initial and repeated LPBV examinations between December 2008 and July 2014. Fifteen patients were excluded due to pulmonary comorbidities, and a total of 81 patients were included in this study. Acute pulmonary embolism (PE) was diagnosed in 46 of the patients (56.7%). LPBV images were three-dimensionally reconstructed with two threshold ranges: 1–120 HU (V{sub 120}) and 1–5 HU (V{sub 5}), and the relative value of V{sub 5} per V{sub 120} expressed as %V{sub 5}. These values were subsequently compared with indicators of the severity of PE, such as the D-dimer level, heart rate and CT measurements. This study was approved by the local ethics committee. Results: In patients with IPCs, the D-dimer, V{sub 5} and %V{sub 5}values were significantly larger (p ≤ 0.01) in the initial LPBV, although these differences disappeared in subsequent LPBV after treatment. The right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio and %V{sub 5} values were also significantly reduced, whereas the V{sub 5} value did not significantly decrease (p = 0.07), but V{sub 120} value significantly increased (p < 0.001) after treatment. However, in

  5. A hyperoxic lung injury model in premature rabbits: the influence of different gestational ages and oxygen concentrations.

    Directory of Open Access Journals (Sweden)

    Roberta Munhoz Manzano

    Full Text Available BACKGROUND: Many animal models have been developed to study bronchopulmonary dysplasia (BPD. The preterm rabbit is a low-cost, easy-to-handle model, but it has a high mortality rate in response to the high oxygen concentrations used to induce lung injury. The aim of this study was to compare the mortality rates of two models of hyperoxia-induced lung injury in preterm rabbits. METHODS: Pregnant New Zealand white rabbits were subjected to caesarean section on gestational day 28 or 29 (full term  = 31 days. The premature rabbits in the 28-day gestation group were exposed to room air or FiO₂ ≥95%, and the rabbits in the 29-day gestation group were exposed to room air or FiO₂  = 80% for 11 days. The mean linear intercept (Lm, internal surface area (ISA, number of alveoli, septal thickness and proportion of elastic and collagen fibers were quantified. RESULTS: The survival rates in the 29-day groups were improved compared with the 28-day groups. Hyperoxia impaired the normal development of the lung, as demonstrated by an increase in the Lm, the septal thickness and the proportion of elastic fibers. Hyperoxia also decreased the ISA, the number of alveoli and the proportion of collagen fibers in the 28-day oxygen-exposed group compared with the control 28-day group. A reduced number of alveoli was found in the 29-day oxygen exposed animals compared with the control 29-day group. CONCLUSIONS: The 29-day preterm rabbits had a reduced mortality rate compared with the 28-day preterm rabbits and maintained a reduction in the alveoli number, which is comparable to BPD in humans.

  6. High-frequency oscillatory ventilation is not superior to conventional mechanical ventilation in surfactant-treated rabbits with lung injury

    NARCIS (Netherlands)

    D.A.M.P.J. Gommers (Diederik); A. Hartog (Anneke); R. Schnabel; A. de Jaegere (Anne); B.F. Lachmann (Burkhard)

    1999-01-01

    textabstractThe aim of this study was to compare high-frequency oscillatory ventilation (HFOV) with conventional mechanical ventilation (CMV) with and without surfactant in the treatment of surfactant-deficient rabbits. A previously described saline lung lavage model of

  7. Whole-liver MR perfusion imaging in rabbit liver VX2 tumors: early findings of coagulative necrosis after percutaneous ethanol injection therapy

    International Nuclear Information System (INIS)

    Zhang Wanshi; Wang Dong; Meng Limin; Shi Huiping; Song Yunlong; Wu Bing

    2007-01-01

    Objective: To investigate the value of whole-liver MR perfusion imaging (MRPI) for early detection of coagulative necrosis after percutaneous ethanol injection (PEI) in rabbit liver VX 2 tumors. Methods: VX 2 tumor cell suspension was inoculated into rabbit liver and liver VX 2 tumors [diameter of (2.6 ± 0.6) cm] were induced in 10 male rabbits. MR T 1 WI and T 2 WI were performed to monitor the development of the liver tumor on the 2 nd and 3 rd week after inoculation. Whole-liver MRPI was performed in the 10 rabbits with liver VX 2 tumors before and 6 days after PEI therapy (1.0 ml ethanol was injected into the most enhanced tumor region under CT guiding). Signal intensity (SI) values of untreated tumor parts and treated areas 6 days after PEI were recorded respectively. The steepest slope (SS) and bolus arrival time (T0) of SI-time curves were measured. The t-Student test was used in statistical analysis of the data. Results: There was significant difference in MRPI data between untreated tumor parts [T0: (16.0 ± 1.2) s and SS: 38.9 ± 2.2] and treated areas [T0: (50.8 ± 5.9) s and SS: 6.0 ± 1.2] 6 days after PEI(t was 15.8 and -39.6 respectively, P 1 WI and T 2 WI could not show any differences between untreated tumor parts and treated areas. Conclusion: Whole-liver MRPI could detect coagulative necrosis of rabbit liver VX 2 tumors after PEI early. Disappearance of early enhancement can be a potential marker for efficacy of PEI. (authors)

  8. Non-contrast-enhanced perfusion and ventilation assessment of the human lung by means of fourier decomposition in proton MRI.

    Science.gov (United States)

    Bauman, Grzegorz; Puderbach, Michael; Deimling, Michael; Jellus, Vladimir; Chefd'hotel, Christophe; Dinkel, Julien; Hintze, Christian; Kauczor, Hans-Ulrich; Schad, Lothar R

    2009-09-01

    Assessment of regional lung perfusion and ventilation has significant clinical value for the diagnosis and follow-up of pulmonary diseases. In this work a new method of non-contrast-enhanced functional lung MRI (not dependent on intravenous or inhalative contrast agents) is proposed. A two-dimensional (2D) true fast imaging with steady precession (TrueFISP) pulse sequence (TR/TE = 1.9 ms/0.8 ms, acquisition time [TA] = 112 ms/image) was implemented on a 1.5T whole-body MR scanner. The imaging protocol comprised sets of 198 lung images acquired with an imaging rate of 3.33 images/s in coronal and sagittal view. No electrocardiogram (ECG) or respiratory triggering was used. A nonrigid image registration algorithm was applied to compensate for respiratory motion. Rapid data acquisition allowed observing intensity changes in corresponding lung areas with respect to the cardiac and respiratory frequencies. After a Fourier analysis along the time domain, two spectral lines corresponding to both frequencies were used to calculate the perfusion- and ventilation-weighted images. The described method was applied in preliminary studies on volunteers and patients showing clinical relevance to obtain non-contrast-enhanced perfusion and ventilation data.

  9. Surfactant nebulisation : lung function, surfactant distribution and pulmonary blood flow distribution in lung lavaged rabbits

    NARCIS (Netherlands)

    Dijk, Peter H.; Heikamp, A; Bambang Oetomo, Sidarto

    1997-01-01

    Objective: Surfactant nebulisation is a promising alternative to surfactant instillation in newborns with the respiratory distress syndrome. Although less surfactant is deposited in the lung, it improves gas exchange, probably due to a superior distribution. We hypothesize that a more uniform

  10. High-resolution pulmonary ventilation and perfusion PET/CT allows for functionally adapted intensity modulated radiotherapy in lung cancer

    International Nuclear Information System (INIS)

    Siva, Shankar; Thomas, Roshini; Callahan, Jason; Hardcastle, Nicholas; Pham, Daniel; Kron, Tomas; Hicks, Rodney J.; MacManus, Michael P.; Ball, David L.; Hofman, Michael S.

    2015-01-01

    Background and purpose: To assess the utility of functional lung avoidance using IMRT informed by four-dimensional (4D) ventilation/perfusion (V/Q) PET/CT. Materials and methods: In a prospective clinical trial, patients with non-small cell lung cancer (NSCLC) underwent 4D-V/Q PET/CT scanning before 60 Gy of definitive chemoradiation. Both “highly perfused” (HPLung) and “highly ventilated” (HVLung) lung volumes were delineated using a 70th centile SUV threshold, and a “ventilated lung volume” (VLung) was created using a 50th centile SUV threshold. For each patient four IMRT plans were created, optimised to the anatomical lung, HPLung, HVLung and VLung volumes, respectively. Improvements in functional dose volumetrics when optimising to functional volumes were assessed using mean lung dose (MLD), V5, V10, V20, V30, V40, V50 and V60 parameters. Results: The study cohort consisted of 20 patients with 80 IMRT plans. Plans optimised to HPLung resulted in a significant reduction of functional MLD by a mean of 13.0% (1.7 Gy), p = 0.02. Functional V5, V10 and V20 were improved by 13.2%, 7.3% and 3.8% respectively (p-values < 0.04). There was no significant sparing of dose to functional lung when adapting to VLung or HVLung. Plan quality was highly consistent with a mean PTV D95 and D5 ranging from 60.8 Gy to 61.0 Gy and 63.4 Gy to 64.5 Gy, respectively, and mean conformity and heterogeneity index ranging from 1.11 to 1.17 and 0.94 to 0.95, respectively. Conclusion: IMRT plans adapted to perfused but not ventilated lung on 4D-V/Q PET/CT allowed for reduced dose to functional lung whilst maintaining consistent plan quality

  11. Lung scans with significant perfusion defects limited to matching pleural effusions have a low probability of pulmonary embolism

    International Nuclear Information System (INIS)

    Datz, F.L.; Bedont, R.A.; Taylor, A.

    1985-01-01

    Patients with a pleural effusion on chest x-ray often undergo a lung scan to exclude pulmonary embolism (PE). According to other studies, when the scan shows a perfusion defect equal in size to a radiographic abnormality on chest x-ray, the scan should be classified as indeterminate or intermediate probability for PE. However, since those studies dealt primarily with alveolar infiltrates rather than pleural effusions, the authors undertook a retrospective study to determine the probability of PE in patients with pleural effusion and a matching perfusion defect. The authors reviewed 451 scans and x-rays of patients studied for suspected PE. Of those, 53 had moderate or large perfusion defects secondary to pleural effusion without other significant (>25% of a segment) effusion without other significant (>25% of a segment) defects on the scan. Final diagnosis was confirmed by pulmonary angiography (16), thoracentesis (40), venography (11), other radiographic and laboratory studies, and clinical course. Of the 53 patients, only 2 patients had venous thrombotic disease. One patient had PE on pulmonary angiography, the other patient had thrombophlebitis on venography. The remainder of the patients had effusions due to congestive heart failure (12), malignancy (12), infection (7), trauma (7), collegen vascular disease (7), sympathetic effusion (3) and unknown etiology (3). The authors conclude that lung scans with significant perfusion defects limited to matching pleural effusions on chest x-ray have a low probability for PE

  12. Pyrrolidine dithiocarbamate administered during ex-vivo lung perfusion promotes rehabilitation of injured donor rat lungs obtained after prolonged warm ischemia.

    Directory of Open Access Journals (Sweden)

    Cyril Francioli

    Full Text Available Damaged lung grafts obtained after circulatory death (DCD lungs and warm ischemia may be at high risk of reperfusion injury after transplantation. Such lungs could be pharmacologically reconditioned using ex-vivo lung perfusion (EVLP. Since acute inflammation related to the activation of nuclear factor kappaB (NF-κB is instrumental in lung reperfusion injury, we hypothesized that DCD lungs might be treated during EVLP by pyrrolidine dithiocarbamate (PDTC, an inhibitor of NF-κB. Rat lungs exposed to 1h warm ischemia and 2 h cold ischemia were subjected to EVLP during 4h, in absence (CTRL group, N = 6 or in presence of PDTC (2.5g/L, PDTC group, N = 6. Static pulmonary compliance (SPC, peak airway pressure (PAWP, pulmonary vascular resistance (PVR, and oxygenation capacity were determined during EVLP. After EVLP, we measured the weight gain of the heart-lung block (edema, and the concentration of LDH (cell damage, proteins (permeability edema and of the cytokines IL-6, TNF-α and CINC-1 in bronchoalveolar lavage (BAL, and we evaluated NF-κB activation by the degree of phosphorylation and degradation of its inhibitor IκBα in lung tissue. In CTRL, we found significant NF-κB activation, lung edema, and a massive release of LDH, proteins and cytokines. SPC significantly decreased, PAWP and PVR increased, while oxygenation tended to decrease. Treatment with PDTC during EVLP inhibited NF-κB activation, did not influence LDH release, but markedly reduced lung edema and protein concentration in BAL, suppressed TNFα and IL-6 release, and abrogated the changes in SPC, PAWP and PVR, with unchanged oxygenation. In conclusion, suppression of innate immune activation during EVLP using the NF-κB inhibitor PDTC promotes significant improvement of damaged rat DCD lungs. Future studies will determine if such rehabilitated lungs are suitable for in vivo transplantation.

  13. The safety of dipyridamole in patients undergoing myocardial perfusion scintigraphy prior to lung volume reduction surgery

    International Nuclear Information System (INIS)

    Roman, M.R.; Angelides, S.; Parker, M.K.; Silva, I. da; Freeman, A.P.

    2001-01-01

    Patients with end-stage chronic obstructive pulmonary disease (COPD) undergoing lung volume reduction surgery (LVRS) are at high risk of peri-operative cardiac complications, and myocardial perfusion scintigraphy (MPS) is commonly used for risk stratification. This study prospectively assessed the safety of dipyridamole in these patients and compared the incidence of side-effects (particularly dyspnoea) with that in patients undergoing dipyridamole MPS prior to elective non-cardiothoracic surgery. Fifty patients were enrolled: 25 in the LVRS cohort (13 males, 12 females), with a mean age of 65 years and a mean FEV 1 of 0.79 l, and 25 (with no history of asthma or COPD) in the control cohort (14 males, 11 females), with a mean age of 66 years. Fourteen patients (56%) in each group developed side-effects. Dyspnoea was reported by five patients (20%) in the LVRS and two patients (8%) in the control cohort (P=NS). One patient in each cohort developed severe hypotension and bradycardia. Eight (32%) other patients developed minor side-effects in the LVRS cohort compared with 11 (44%) in the control group. All side-effects responded promptly to intravenous aminophylline. In summary, there was a statistically non-significant increase in the incidence of dyspnoea in patients with end-stage COPD and all side-effects responded to aminophylline. Thus, dipyridamole can be used safely in these patients. (orig.)

  14. Preparation of Tc-99m-macroaggregated albumin from recombinant human albumin for lung perfusion imaging.

    Science.gov (United States)

    Hunt, A P; Frier, M; Johnson, R A; Berezenko, S; Perkins, A C

    2006-01-01

    Human serum albumin (HSA) extracted from pooled blood taken from human donors is used in the production of (99m)Tc-labelled macroaggregated albumin (MAA) for lung perfusion imaging. However, concerns for the safety of blood-derived products due to potential contamination by infective agents (e.g. new variant CJD), make alternative production methods necessary. Recombinant DNA technology is a promising method of albumin production avoiding problems associated with human-derived HSA. This paper presents results comparing MAA prepared from recombinant human albumin (rHA, Recombumin) (rMAA) with in-house produced HSA MAA (hMAA) and commercially available MAA (cMAA). (99m)Tc-MAA was prepared using previously published production methods by heating a mixture of albumin and stannous chloride in acetate buffer (pH 5.4) at 70 degrees C for 20 min. Parameters investigated include aggregate size, radiolabelling efficiency, radiochemical and aggregate stability at 4 degrees C and in vitro (in whole human blood) at 37 degrees C and biodistribution studies. Results showed that rMAA could be produced with similar morphology, labelling efficiency and stability to hMAA and cMAA. Our findings confirm that rHA shows significant potential as a direct replacement for HSA in commercially available MAA.

  15. Lung Perfusion SPECT: Application in a Patient With Tetralogy of Fallot and Suspected Pulmonary Thromboemboli

    International Nuclear Information System (INIS)

    Ranji Amjad, Mina; Abbasi, Mehrshad; Farzanehfar, Saeed

    2015-01-01

    A 22-year-old woman presented with acute left-sided pleuritic chest pain and dyspnea 6 days after surgery for revision of the stenotic central aortopulmonary shunt. She had a history of tetralogy of Fallot (TOF), pulmonary valve stenosis, ventricular septal defect and major aortopulmonary collateral artery. Her Waterston shunt was placed when she was 5 years old and stented and re-dilated after stenosis. Acute pulmonary thromboemboli (PTE) was suspected and pulmonary perfusion scan was performed with 4 mCi 99m Technetium labeled macroaggregated albumin. The left lung was globally hypoperfused with evident uptake in the brain, renal parenchyma and thyroid. SPECT images revealed a segmental wedge-shaped peripheral defect in the posterior segment of the left upper lobe. The scan was interpreted as acute/chronic PTE or vascular abnormality. CT angiography excluded PTE; nevertheless the patient was treated with a therapeutic dose of heparin changed to warfarin and was discharged with improvement of the symptoms. Pulmonary artery angiography was not performed

  16. A comparison of perfusion computed tomography and contrast enhanced computed tomography on radiation target volume delineation using rabbit VX2 brain tumor model

    International Nuclear Information System (INIS)

    Sun Changjin; Luo Yunxiu; Yu Jinming; Lu Haibo; Li Chao; Zhang Dekang; Huang Jianming; Wang Jie; Lang Jinyi

    2010-01-01

    Objective: To compare the accuracy of blood volume perfusion imaging (perfusion CT)with contrast enhanced 64-slice spiral computed tomography (CECT) in the evaluation of gross tumor volume (GTV) and clinical target volume (CTV) using rabbits with VX2 brain tumor. Methods: Perfusion CT and CECT were performed in 20 rabbits with VX2 brain tumor. The GTV and CTV calculated with the maximal and minimal diameter of each tumor in the blood volume (BV) maps and CECT were measured and compared to those in pathological specimens. Results: The mean value of the maximal and minimal diameter of GTV was (8.19 ± 2.29) mm and (4.83 ± 1.31) mm in pathological specimens, (11.98 ±3.29) mm and (7.03±1.82) mm in BV maps, while (6.36±3.85) mm and (3.17±1.93) mm in CECT images, which were significantly different (pathological specimen vs. BV map, t = 7.17, P =0.000;pathological specimen vs. CECT, t = 8.37, P = 0.000, respectively). The mean value of the maximal and minimal diameter of CTV in pathologic specimens was (12.87 ± 3.74) mm and (7.71 ± 2.15) mm, which was significantly different from that of GTV and CTV in CECT (t = - 3. 18, P = 0. 005 and t = - 4.24, P =0.000; t= -11.59,P=0.000 and t= -9.39, P=0.000), while similar with that of GTV in BV maps (t = - 1.95,P = 0. 067; t = - 2. 06, P = 0. 054). For CECT, the margin from GTV to CTV was 81.83% ±40.33% for the maximal diameter and 276.73% ± 131.46% for the minimal. While for BV maps, the margin was 7.93% ± 17. 84% and 12.52% ± 27. 83%, which was significant different from that for CECT images (t=7.36, P=0. 000 and t= -8.78, P=0.000). Conclusions: Compared with CECT, the BV map from 64-slice spiral CT perfusion imaging might have higher accuracy in target volume delineation for brain tumor. (authors)

  17. Applications and interpretation of krypton 81m ventilation/technetium 99m macroaggregate perfusion lung scanning in childhood

    Science.gov (United States)

    Davies, Hugh Trevor Frimston

    Radionuclide ventilation perfusion lung scans now play an important part in the investigation of paediatric lung disease, providing a safe, noninvasive assessment of regional lung function in children with suspected pulmonary disease. In paediatric practice the most suitable radionuclides are Krypton 81m (Kr81m) and Technetium 99m (Tc99m), which are jointly used in the Kr81m ventilation/Tc99m macroaggregate perfusion lung scan (V/Q lung scan). The Kr81m ventilation scan involves a low radiation dose, requires little or no subject cooperation and because of the very short half life of Kr81m (13 seconds) the steady state image acquired during continuous inhalation of the radionuclide is considered to reflect regional distribution of ventilation. It is now the most important noninvasive method available for the investigation of the regional abnormalities of ventilation characteristic of many congenital and acquired paediatric respiratory diseases, such as diaphragmatic hernia, pulmonary sequestration, bronchopulmonary dysplasia, foreign body inhalation and bronchiectasis. It improves diagnostic accuracy, aids clinical decision making and is used to monitor the progress of disease and response to therapy. Theoretical analysis of the steady state Kr81m ventilation image suggests that it may only reflect regional ventilation when specific ventilation (ventilation per unit volume of lung) is within or below the normal adult range (1-3 L/L/min). At higher values such as those seen in neonates and infants (8-15 L/L/min) Kr81m activity may reflect regional lung volume rather than ventilation, a conclusion supported by the studies of Ciofetta et al. There is some controversy on this issue as animal studies have demonstrated that the Kr81m image reflects ventilation over a much wider range of specific ventilation (up to 13 L/L/min). A clinical study of sick infants and very young children is in agreement with this animal work and suggests that the steady state Kr81m image

  18. Phosphodiesterase-4 inhibition alters gene expression and improves isoniazid-mediated clearance of Mycobacterium tuberculosis in rabbit lungs.

    Directory of Open Access Journals (Sweden)

    Selvakumar Subbian

    2011-09-01

    Full Text Available Tuberculosis (TB treatment is hampered by the long duration of antibiotic therapy required to achieve cure. This indolent response has been partly attributed to the ability of subpopulations of less metabolically active Mycobacterium tuberculosis (Mtb to withstand killing by current anti-TB drugs. We have used immune modulation with a phosphodiesterase-4 (PDE4 inhibitor, CC-3052, that reduces tumor necrosis factor alpha (TNF-α production by increasing intracellular cAMP in macrophages, to examine the crosstalk between host and pathogen in rabbits with pulmonary TB during treatment with isoniazid (INH. Based on DNA microarray, changes in host gene expression during CC-3052 treatment of Mtb infected rabbits support a link between PDE4 inhibition and specific down-regulation of the innate immune response. The overall pattern of host gene expression in the lungs of infected rabbits treated with CC-3052, compared to untreated rabbits, was similar to that described in vitro in resting Mtb infected macrophages, suggesting suboptimal macrophage activation. These alterations in host immunity were associated with corresponding down-regulation of a number of Mtb genes that have been associated with a metabolic shift towards dormancy. Moreover, treatment with CC-3052 and INH resulted in reduced expression of those genes associated with the bacterial response to INH. Importantly, CC-3052 treatment of infected rabbits was associated with reduced ability of Mtb to withstand INH killing, shown by improved bacillary clearance, from the lungs of co-treated animals compared to rabbits treated with INH alone. The results of our study suggest that changes in Mtb gene expression, in response to changes in the host immune response, can alter the responsiveness of the bacteria to antimicrobial agents. These findings provide a basis for exploring the potential use of adjunctive immune modulation with PDE4 inhibitors to enhance the efficacy of existing anti-TB treatment.

  19. Hydrogen Gas Inhalation Attenuates Seawater Instillation-Induced Acute Lung Injury via the Nrf2 Pathway in Rabbits.

    Science.gov (United States)

    Diao, Mengyuan; Zhang, Sheng; Wu, Lifeng; Huan, Le; Huang, Fenglou; Cui, Yunliang; Lin, Zhaofen

    2016-12-01

    Seawater instillation-induced acute lung injury involves oxidative stress and apoptosis. Although hydrogen gas inhalation is reportedly protective in multiple types of lung injury, the effect of hydrogen gas inhalation on seawater instillation-induced acute lung injury remains unknown. This study investigated the effect of hydrogen gas on seawater instillation-induced acute lung injury and explored the mechanisms involved. Rabbits were randomly assigned to control, hydrogen (2 % hydrogen gas inhalation), seawater (3 mL/kg seawater instillation), and seawater + hydrogen (3 mL/kg seawater instillation + 2 % hydrogen gas inhalation) groups. Arterial partial oxygen pressure and lung wet/dry weight ratio were detected. Protein content in bronchoalveolar lavage fluid (BALF) and serum as well as tumor necrosis factor (TNF)-α, interleukin (IL)-1β, and IL-6 levels were determined. Hematoxylin-eosin staining was used to monitor changes in lung specimens, and malondialdehyde (MDA) content and myeloperoxidase (MPO) activity were assayed. In addition, NF-E2-related factor (Nrf) 2 and heme oxygenase (HO)-1 mRNA and protein expression were measured, and apoptosis was assessed by measuring caspase-3 expression and using terminal deoxy-nucleotidyl transferase dUTP nick end-labeling (TUNEL) staining. Hydrogen gas inhalation markedly improved lung endothelial permeability and decreased both MDA content and MPO activity in lung tissue; these changes were associated with decreases in TNF-α, IL-1β, and IL-6 in BALF. Hydrogen gas also alleviated histopathological changes and cell apoptosis. Moreover, Nrf2 and HO-1 expressions were significantly activated and caspase-3 expression was inhibited. These results demonstrate that hydrogen gas inhalation attenuates seawater instillation-induced acute lung injury in rabbits and that the protective effects observed may be related to the activation of the Nrf2 pathway.

  20. Fibroblasts are in a position to provide directional information to migrating neutrophils during pneumonia in rabbit lungs.

    Science.gov (United States)

    Behzad, A R; Chu, F; Walker, D C

    1996-05-01

    Previous findings have shown that pulmonary fibroblasts are associated with preexisting holes in the endothelial and epithelial basal laminae through which neutrophils appear to enter and leave the interstitium as they migrate from capillaries to alveoli. To determine their role in neutrophil migration, fibroblast organization within the interstitium was assessed by transmission electron microscope observations of serial-sectioned rabbit lung tissue. Interstitial fibroblasts were found to physically interconnect the endothelial basal lamina holes to epithelial basal lamina holes. Morphometric assessment of rabbit lung tissue instilled with Streptococcus pneumoniae revealed that approximately 70% of the surface area density of migrating neutrophils is in close contact (15 nm or less) with interstitial fibroblasts and extracellular matrix elements (30 and 40%, respectively). Although migrating neutrophils were close enough to adhere to both fibroblasts and extracellular elements, the interstitial fibroblasts are organized in a manner that would allow them to provide directional information to the neutrophils. A model illustrating this process is proposed.

  1. Pulmonary O2 transfer during pulsatile and non-pulsatile perfusion.

    Science.gov (United States)

    Hauge, A; Nicolaysen, G

    1980-07-01

    The importance of the perfusion pattern for the oxygen transfer has been examined in isolated rabbit lungs perfused with plasma at constant volume inflow. The lungs were ventilated with constant tidal volume and constant end-expiratory pressure. Following a standardized rise in FIO2 the rate of rise in pulmonary venous PO2 (delta PO2/delta t) was measured during alternately pulsatile and non-pulsatile perfusion in normal lungs and in lungs made edematous by elevation of left atrial pressure. In normal lungs there was no difference in delta PO2/delta t when the two modes of perfusion were compared. In edematous lungs delta PO/delta t was statistically higher during pulsatile perfusion, indicating a beneficial effect of flow- and pressure pulsations, e.g. a better distribution of V/Q ratios throughout the lungs. In a separate series of expts. the advancement of a high O2 front through the airways was measured, and the two perfusion patterns compared. Since no difference was found, we suggest that the phenomenon of "cardiogenic gas mixing" in the airways in vivo is a result of a direct action of the heart on the lungs rather than arterial pulsations.

  2. Region of interest-based versus whole-lung segmentation-based approach for MR lung perfusion quantification in 2-year-old children after congenital diaphragmatic hernia repair

    Energy Technology Data Exchange (ETDEWEB)

    Weis, M.; Sommer, V.; Hagelstein, C.; Schoenberg, S.O.; Neff, K.W. [Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Mannheim (Germany); Zoellner, F.G. [Heidelberg University, Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Mannheim (Germany); Zahn, K. [University of Heidelberg, Department of Paediatric Surgery, University Medical Center Mannheim, Medical Faculty Mannheim, Mannheim (Germany); Schaible, T. [Heidelberg University, Department of Paediatrics, University Medical Center Mannheim, Medical Faculty Mannheim, Mannheim (Germany)

    2016-12-15

    With a region of interest (ROI)-based approach 2-year-old children after congenital diaphragmatic hernia (CDH) show reduced MR lung perfusion values on the ipsilateral side compared to the contralateral. This study evaluates whether results can be reproduced by segmentation of whole-lung and whether there are differences between the ROI-based and whole-lung measurements. Using dynamic contrast-enhanced (DCE) MRI, pulmonary blood flow (PBF), pulmonary blood volume (PBV) and mean transit time (MTT) were quantified in 30 children after CDH repair. Quantification results of an ROI-based (six cylindrical ROIs generated of five adjacent slices per lung-side) and a whole-lung segmentation approach were compared. In both approaches PBF and PBV were significantly reduced on the ipsilateral side (p always <0.0001). In ipsilateral lungs, PBF of the ROI-based and the whole-lung segmentation-based approach was equal (p=0.50). In contralateral lungs, the ROI-based approach significantly overestimated PBF in comparison to the whole-lung segmentation approach by approximately 9.5 % (p=0.0013). MR lung perfusion in 2-year-old children after CDH is significantly reduced ipsilaterally. In the contralateral lung, the ROI-based approach significantly overestimates perfusion, which can be explained by exclusion of the most ventral parts of the lung. Therefore whole-lung segmentation should be preferred. (orig.)

  3. Region of interest-based versus whole-lung segmentation-based approach for MR lung perfusion quantification in 2-year-old children after congenital diaphragmatic hernia repair

    International Nuclear Information System (INIS)

    Weis, M.; Sommer, V.; Hagelstein, C.; Schoenberg, S.O.; Neff, K.W.; Zoellner, F.G.; Zahn, K.; Schaible, T.

    2016-01-01

    With a region of interest (ROI)-based approach 2-year-old children after congenital diaphragmatic hernia (CDH) show reduced MR lung perfusion values on the ipsilateral side compared to the contralateral. This study evaluates whether results can be reproduced by segmentation of whole-lung and whether there are differences between the ROI-based and whole-lung measurements. Using dynamic contrast-enhanced (DCE) MRI, pulmonary blood flow (PBF), pulmonary blood volume (PBV) and mean transit time (MTT) were quantified in 30 children after CDH repair. Quantification results of an ROI-based (six cylindrical ROIs generated of five adjacent slices per lung-side) and a whole-lung segmentation approach were compared. In both approaches PBF and PBV were significantly reduced on the ipsilateral side (p always <0.0001). In ipsilateral lungs, PBF of the ROI-based and the whole-lung segmentation-based approach was equal (p=0.50). In contralateral lungs, the ROI-based approach significantly overestimated PBF in comparison to the whole-lung segmentation approach by approximately 9.5 % (p=0.0013). MR lung perfusion in 2-year-old children after CDH is significantly reduced ipsilaterally. In the contralateral lung, the ROI-based approach significantly overestimates perfusion, which can be explained by exclusion of the most ventral parts of the lung. Therefore whole-lung segmentation should be preferred. (orig.)

  4. Lung perfusion and ventilation scintigraphy in pre- and postoperative diagnostics; Lungenperfusions- und Ventilationsszintigraphie in der prae- und postoperativen Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Sandrock, D.; Munz, D.L. [Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Charite, Medizinische Fakultaet der Humboldt-Univ. zu Berlin (Germany)

    1998-03-01

    Lung perfusion (Tc-99m labeled albumin particles) and ventilation (Xe-133 gas) are used prior to thoracic surgery in order to evaluate changes in perfusion and ventilation due to the underlying diseases. Furthermore, perfusion scintigraphy allows combined with spirometry the prediction of the postinterventional vital capacity and the forced expiratory volume in 1 s. The correlation coefficient for this procedure compared with values measured postoperatively are in the range of 0.8. The method allows the assessment of operability in terms of postinterventional function. (orig.) [Deutsch] Die Lungenperfusions- (mit Tc-99m-markierten Albuminpartikeln) und die Ventilationsszintigraphie (mit Xe-133 als Gas) werden vor thoraxchirugrischen Eingriffen zur Beurteilung der durch die Grund- oder weitere Erkrankungen bedingte Einschraenkungen von Perfusion und Belueftung eingesetzt. Die Perfusionsszintigraphie erlaubt in Kombination mit der Spirometrie ausserdem die Vorausberechnung der postoperativ zu erwartenden Vitalkapazitaet und des forcierten exspiratorischen Erstsekundenvolumens. Im Vergleich mit den postoperativ gemessenen Volumina liegen die Korrelationskoeffizienten um 0,8. Die Methode ermoeglicht daher eine Beurteilung der Operabilitaet bezueglich der postoperativen Lungenfunktion. (orig.)

  5. [The effect of portal blood stasis on lung and renal injury induced by hepatic ischemia reperfusion in a rabbit model].

    Science.gov (United States)

    Wang, Ye; Yang, Jia-mei; Hou, Yuan-kai; Li, Dian-qi; Hu, Ming-hua; Liu, Peng

    2008-04-15

    To investigate the effect and mechanism of portal blood stasis on lung and renal injury induced by hepatic ischemia reperfusion. A rabbit hepatic ischemia reperfusion injury model was established by hepatic portal occlusion and in situ hypothermic irrigation for 30 min. Twenty-four New Zealand white rabbits were employed and randomly divided into 3 groups equally by different dosage of portal blood stasis removal: group A5 (5 ml blood removal), group A10 (10 ml blood removal),and group B (no blood removal). Eight rabbits were served as controls with no hepatic portal occlusion and hypothermic irrigation. After reperfusion 4 h serum endotoxin content, tumor necrosis factor-alpha (TNF-alpha), urea nitrogen (BUN), and creatinine (Cr) were examined respectively, meantime lung and kidney tissues were sampled to determine the content of malondialdehyde (MDA), superoxide dismutase (SOD), the pathology, and wet to dry weight ratio, broncho-alveolar lavage fluid protein content in lung tissues. Removing portal blood stasis ameliorated lung and renal injury as shown by decreasing the level of serum endotoxin, TNF-alpha, BUN, Cr, wet to dry weight ratio, broncho-alveolar lavage fluid protein content, MDA, SOD. TNF-alpha, Cr, broncho-alveolar lavage fluid protein content in lung tissues and MDA in kidney tissue in group A5 were significantly reduced compared with those in group B (P portal blood stasis before the resume of splanchnic circulation may ameliorate the lung and renal injury induced by hepatic ischemia reperfusion. The possible mechanism may be that portal blood stasis removal reduces endotoxin absorption, and further decreases production of serum TNF-alpha.

  6. Co-registered perfusion SPECT/CT: Utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates

    International Nuclear Information System (INIS)

    Takenaka, Daisuke; Ohno, Yoshiharu; Koyama, Hisanobu; Nogami, Munenobu; Onishi, Yumiko; Matsumoto, Keiko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2010-01-01

    Purpose: To directly compare the capabilities of perfusion scan, SPECT, co-registered SPECT/CT, and quantitatively and qualitatively assessed MDCT (i.e. quantitative CT and qualitative CT) for predicting postoperative clinical outcome for lung volume reduction surgery (LVRS) candidates. Materials and methods: Twenty-five consecutive candidates (19 men and six women, age range: 42-72 years) for LVRS underwent preoperative CT and perfusion scan with SPECT. Clinical outcome of LVRS for all subjects was also assessed by determining the difference between pre- and postoperative forced expiratory volume in 1 s (FEV 1 ) and 6-min walking distance (6MWD). All SPECT examinations were performed on a SPECT scanner, and co-registered to thin-section CT by using commercially available software. On planar imaging, SPECT and SPECT/CT, upper versus lower zone or lobe ratios (U/Ls) were calculated from regional uptakes between upper and lower lung fields in the operated lung. On quantitatively assessed CT, U/L for all subjects was assessed from regional functional lung volumes. On qualitatively assessed CT, planar imaging, SPECT and co-registered SPECT/CT, U/Ls were assessed with a 4-point visual scoring system. To compare capabilities of predicting clinical outcome, each U/L was statistically correlated with the corresponding clinical outcome. Results: Significantly fair or moderate correlations were observed between quantitatively and qualitatively assessed U/Ls obtained with all four methods and clinical outcomes (-0.60 ≤ r ≤ -0.42, p < 0.05). Conclusion: Co-registered perfusion SPECT/CT has better correlation with clinical outcome in LVRS candidates than do planar imaging, SPECT or qualitatively assessed CT, and is at least as valid as quantitatively assessed CT.

  7. Co-registered perfusion SPECT/CT: Utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates

    Energy Technology Data Exchange (ETDEWEB)

    Takenaka, Daisuke [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.j [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Koyama, Hisanobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Nogami, Munenobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, 2-2, Minatojima Minamimachi Chuo-ku, Kobe, Hyogo, 650-0047 (Japan); Onishi, Yumiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Matsumoto, Keiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Department of Radiology, University of Yamanashi, 1110 Shimogato, Chuo, Yamanashi, 409-3898 (Japan); Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan)

    2010-06-15

    Purpose: To directly compare the capabilities of perfusion scan, SPECT, co-registered SPECT/CT, and quantitatively and qualitatively assessed MDCT (i.e. quantitative CT and qualitative CT) for predicting postoperative clinical outcome for lung volume reduction surgery (LVRS) candidates. Materials and methods: Twenty-five consecutive candidates (19 men and six women, age range: 42-72 years) for LVRS underwent preoperative CT and perfusion scan with SPECT. Clinical outcome of LVRS for all subjects was also assessed by determining the difference between pre- and postoperative forced expiratory volume in 1 s (FEV{sub 1}) and 6-min walking distance (6MWD). All SPECT examinations were performed on a SPECT scanner, and co-registered to thin-section CT by using commercially available software. On planar imaging, SPECT and SPECT/CT, upper versus lower zone or lobe ratios (U/Ls) were calculated from regional uptakes between upper and lower lung fields in the operated lung. On quantitatively assessed CT, U/L for all subjects was assessed from regional functional lung volumes. On qualitatively assessed CT, planar imaging, SPECT and co-registered SPECT/CT, U/Ls were assessed with a 4-point visual scoring system. To compare capabilities of predicting clinical outcome, each U/L was statistically correlated with the corresponding clinical outcome. Results: Significantly fair or moderate correlations were observed between quantitatively and qualitatively assessed U/Ls obtained with all four methods and clinical outcomes (-0.60 {<=} r {<=} -0.42, p < 0.05). Conclusion: Co-registered perfusion SPECT/CT has better correlation with clinical outcome in LVRS candidates than do planar imaging, SPECT or qualitatively assessed CT, and is at least as valid as quantitatively assessed CT.

  8. Lung ventilation-perfusion scintigraphy in children on long-term parenteral nutrition

    Energy Technology Data Exchange (ETDEWEB)

    Pifarre, Paloma; Roca, Isabel [Universitat Autonoma de Barcelona, Department of Nuclear Medicine, Hospital de la Vall d' Hebron, Barcelona (Spain); Irastorza, Inaki; Hill, Susan [Great Ormond Street Hospital, Department of Gastroenterology, London (United Kingdom); Simo, Marc [Instituto Universitario Dexeus, Department of Nuclear Medicine, Barcelona (Spain); Biassoni, Lorenzo; Gordon, Isky [Great Ormond Street Hospital, Department of Nuclear Medicine, London (United Kingdom)

    2009-06-15

    Pulmonary emboli (PE) are one of the major complications associated with total parenteral nutrition (TPN). Ventilation-perfusion scintigraphy (V/Q) remains the most used test for the diagnosis of PE and follow-up of patients on TPN. The aim of our study was to demonstrate the high prevalence of undiagnosed PE in children on TPN. The medical and imaging files of 64 patients on TPN who underwent V/Q examinations covering the period of 1986-2004 were reviewed. Children were aged between 3.18 months and 21.6 years. TPN was started at birth (range 0-15 years). All children had a normal chest radiograph and no symptoms at the time of the V/Q scan. A comparative analysis between the prevalence of PE and risk factors number of days per week with lipophilic content of the TPN, bowel inflammation and thrombophilic factors (protein C and S) was performed. Of the 64 patients, 25 (39%) had an abnormal V/Q scan. A total of 29 PE episodes were diagnosed in all patients. Two children had three episodes of PE. The median age at PE diagnosis was 4.6 years. In 17 patients (68%) diagnosis was achieved on the first V/Q scan performed. PE was bilateral in 56% and unilateral in 44%. PE was the main cause of 2 out 15 recorded deaths. All risk factors were associated with an increase in PE prevalence by statistical analysis. PE is underdiagnosed in children on long-term TPN. Lung V/Q scintigraphy is useful in the diagnosis of PE in children with a low pretest probability. (orig.)

  9. Lung perfusion characteristics in pulmonary arterial hypertension (PAH) and peripheral forms of chronic thromboembolic pulmonary hypertension (pCTEPH): Dual-energy CT experience in 31 patients

    Energy Technology Data Exchange (ETDEWEB)

    Giordano, Jessica; Khung, Suonita; Remy, Jacques; Remy-Jardin, Martine [Hospital Calmette (EA 2694), Department of Thoracic Imaging, Lille (France); Duhamel, Alain [University Lille, CHU Lille, Department of Biostatistics, Lille (France); Hossein-Foucher, Claude; Bellevre, Dimitri [University Lille, CHU Lille, Department of Nuclear Medicine, Hospital Salengro, Lille (France); Lamblin, Nicolas [University Lille, CHU Lille, Department of Cardiology, Cardiology Hospital, Lille (France)

    2017-04-15

    To compare lung perfusion in PAH and pCTEPH on dual-energy CT (DECT) examinations. Thirty-one patients with PAH (group 1; n = 19) and pCTEPH (group 2; n = 12) underwent a dual-energy chest CTA with reconstruction of diagnostic and perfusion images. Perfusion alterations were analysed at a segmental level. V/Q scintigraphy was available in 22 patients (group 1: 13/19; group 2: 9/12). CT perfusion was abnormal in 52.6 % of group 1 patients and in 100 % of group 2 patients (p = 0.0051). The patterns of perfusion alteration significantly differed between the two groups (p < 0.0001): (1) in group 1, 96.6 % of segments with abnormal perfusion showed patchy defects; (2) in group 2, the most frequent abnormalities consisted of patchy (58.5 %) and PE-type (37.5 %) defects. Paired comparison of CT perfusion and scintigraphy showed concordant findings in 76.9 % of group 1 (10/13) and 100 % of group 2 (9/9) patients, with a predominant or an exclusive patchy pattern in group 1 and a mixed pattern of abnormalities in group 2. Lung perfusion alterations at DECT are less frequent and more homogeneous in PAH than in pCTEPH, with a high level of concordant findings with V/Q scintigraphy. (orig.)

  10. Relative preservation of peripheral lung function in smoking-related pulmonary emphysema: assessment with 99mTc-MAA perfusion and dynamic 133Xe SPET

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kume, Norihiko; Matsunaga, Naofumi; Ogasawara, Nobuhiko; Motoyama, Kazumi; Hara, Akiko; Matsumoto, Tsuneo

    2000-01-01

    In this study the cross-sectional functional differences between the central and peripheral lung in smokers with pulmonary emphysema were evaluated by lung perfusion and dynamic xenon-133 single-photon emission tomography (SPET). The subjects were 81 patients with a long-term smoking history and relatively advanced emphysema, 17 non-smoker patients with non-obstructive lung diseases and six healthy non-smokers. Regional lung functional difference between the peripheral and central lung was assessed in the upper, middle and lower lung zones by technetium-99m macroaggregated albumin SPET and dynamic 133 Xe SPET. The distribution of emphysematous changes was assessed by density-mask computed tomography (CT) images which depicted abnormally low attenuation areas (LAAs) of less than -960 Hounsfield units. Two hundred and eighty-eight (59.2%) lung zones of 63 (77.7%) patients with pulmonary emphysema showed relative preservation of lung function in the peripheral lung, with a curvilinear band of normal perfusion (a stripe sign) and a significantly faster 133 Xe half-clearance time (T 1/2 ) than in central lung (P 1/2 in the peripheral lung area (P 1/2 values and LAA distributions between the central and peripheral lung. Relative preservation of peripheral lung function seems to be a characteristic feature in smoking-related pulmonary emphysema, and may indicate a lower susceptibility of peripheral parenchyma to the development of this disease. (orig.)

  11. A diagnostic strategy for pulmonary embolism based on standardised pretest probability and perfusion lung scanning: a management study

    International Nuclear Information System (INIS)

    Miniati, Massimo; Monti, Simonetta; Bauleo, Carolina; Scoscia, Elvio; Tonelli, Lucia; Dainelli, Alba; Catapano, Giosue; Formichi, Bruno; Di Ricco, Giorgio; Prediletto, Renato; Carrozzi, Laura; Marini, Carlo

    2003-01-01

    Pulmonary embolism remains a challenging diagnostic problem. We developed a simple diagnostic strategy based on combination of assessment of the pretest probability with perfusion lung scan results to reduce the need for pulmonary angiography. We studied 390 consecutive patients (78% in-patients) with suspected pulmonary embolism. The pretest probability was rated low ( 10%, ≤50%), moderately high (>50%, ≤90%) or high (>90%) according to a structured clinical model. Perfusion lung scans were independently assigned to one of four categories: normal; near-normal; abnormal, suggestive of pulmonary embolism (wedge-shaped perfusion defects); abnormal, not suggestive of pulmonary embolism (perfusion defects other than wedge shaped). Pulmonary embolism was diagnosed in patients with abnormal scans suggestive of pulmonary embolism and moderately high or high pretest probability. Patients with normal or near-normal scans and those with abnormal scans not suggestive of pulmonary embolism and low pretest probability were deemed not to have pulmonary embolism. All other patients were allocated to pulmonary angiography. Patients in whom pulmonary embolism was excluded were left untreated. All patients were followed up for 1 year. Pulmonary embolism was diagnosed non-invasively in 132 patients (34%), and excluded in 191 (49%). Pulmonary angiography was required in 67 patients (17%). The prevalence of pulmonary embolism was 41% (n=160). Patients in whom pulmonary embolism was excluded had a thrombo-embolic risk of 0.4% (95% confidence interval: 0.0%-2.8%). Our strategy permitted a non-invasive diagnosis or exclusion of pulmonary embolism in 83% of the cases (95% confidence interval: 79%-86%), and appeared to be safe. (orig.)

  12. Pulmonary Perfusion Changes as Assessed by Contrast-Enhanced Dual-Energy Computed Tomography after Endoscopic Lung Volume Reduction by Coils.

    Science.gov (United States)

    Lador, Frédéric; Hachulla, Anne-Lise; Hohn, Olivia; Plojoux, Jérôme; Ronot, Maxime; Montet, Xavier; Soccal, Paola M

    2016-01-01

    Endoscopic lung volume reduction by coils (LVRC) is a recent treatment approach for severe emphysema. Furthermore, dual-energy computed tomography (DECT) now offers a combined assessment of lung morphology and pulmonary perfusion. The aim of our study was to assess the impact of LVRC on pulmonary perfusion with DECT. Seventeen patients (64.8 ± 6.7 years) underwent LVRC. DECT was performed prior to and after LVRC. For each patient, lung volumes and emphysema quantification were automatically calculated. Then, 6 regions of interest (ROIs) on the iodine perfusion map were drawn in the anterior, mid, and posterior right and left lungs at 4 defined levels. The ROI values were averaged to obtain lung perfusion as assessed by the lung's iodine concentration (CLung, μg·cm-3). The CLung values were normalized using the left atrial iodine concentration (CLA) to take into account differences between successive DECT scans. The 6-min walk distance (6MWD) improved significantly after the procedure (p = 0.0002). No lung volume changes were observed between successive DECT scans for any of the patients (p = 0.32), attesting the same suspended inspiration. After LVRC, the emphysema index was significantly reduced in the treated lung (p = 0.0014). Lung perfusion increased significantly adjacent to the treated areas (CLung/CLA from 3.4 ± 1.7 to 5.6 ± 2.2, p < 0.001) and in the ipsilateral untreated areas (from 4.1 ± 1.4 to 6.6 ± 1.7, p < 0.001), corresponding to a mean 65 and 61% increase in perfusion, respectively. No significant difference was observed in the contralateral upper and lower areas (from 4.4 ± 1.9 to 4.8 ± 2.1, p = 0.273, and from 4.9 ± 2.0 to 5.2 ± 1.7, p = 0.412, respectively). A significant correlation between increased 6MWD and increased perfusion was found (p = 0.0027, R2 = 0.3850). Quantitative analysis based on DECT acquisition revealed that LVRC results in a significant increase in perfusion in the coil-free areas adjacent to the treated ones, as

  13. Correlation of 68Ga Ventilation-Perfusion PET/CT with Pulmonary Function Test Indices for Assessing Lung Function.

    Science.gov (United States)

    Le Roux, Pierre-Yves; Siva, Shankar; Steinfort, Daniel P; Callahan, Jason; Eu, Peter; Irving, Lou B; Hicks, Rodney J; Hofman, Michael S

    2015-11-01

    Pulmonary function tests (PFTs) are routinely used to assess lung function, but they do not provide information about regional pulmonary dysfunction. We aimed to assess correlation of quantitative ventilation-perfusion (V/Q) PET/CT with PFT indices. Thirty patients underwent V/Q PET/CT and PFT. Respiration-gated images were acquired after inhalation of (68)Ga-carbon nanoparticles and administration of (68)Ga-macroaggregated albumin. Functional volumes were calculated by dividing the volume of normal ventilated and perfused (%NVQ), unmatched and matched defects by the total lung volume. These functional volumes were correlated with forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and diffusing capacity for carbon monoxide (DLCO). All functional volumes were significantly different in patients with chronic obstructive pulmonary disease (P volume of unmatched defects (r = -0.55). Considering %NVQ only, a cutoff value of 90% correctly categorized 28 of 30 patients with or without significant pulmonary function impairment. Our study demonstrates strong correlations between V/Q PET/CT functional volumes and PFT parameters. Because V/Q PET/CT is able to assess regional lung function, these data support the feasibility of its use in radiation therapy and preoperative planning and assessing pulmonary dysfunction in a variety of respiratory diseases. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  14. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    International Nuclear Information System (INIS)

    Suga, K.; Yasuhiko, K.; Iwanaga, H.; Tokuda, O.; Matsunaga, N.

    2009-01-01

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  15. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Suga, K.; Yasuhiko, K. (Dept. of Radiology, St. Hill Hospital, Ube, Yamaguchi (Japan)); Iwanaga, H.; Tokuda, O.; Matsunaga, N. (Dept. of Radiology, Yamaguchi Univ. School of Medicine, Ube, Yamaguchi (Japan))

    2009-01-15

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  16. Isolation of a mannose/N-acetylglucosamine receptor from rabbit lung

    International Nuclear Information System (INIS)

    Lennartz, M.R.; Wileman, T.E.; Stahl, P.D.

    1986-01-01

    The presence of a mannose receptor on alveolar macrophages was first described in 1978 and later extended to other macrophage populations. Recently the novel ligand, mannose-conjugated lactoperoxidase, was used to identify this receptor as a 175kD protein. A 175kD protein exhibiting mannose and N-acetylglucosamine (GlcNAc)-binding properties was isolated from rabbit lung membranes. Membranes were washed with high salt, mannose and EDTA to remove endogenously bound ligand and were subsequently extracted with 1% Triton-X 100. The extract was subjected to affinity chromatography on Mannose-Sepharose followed by GlcNAc-Agarose. Triton was exchanged for 1% CHAPS while the protein was bound to GlcNAc-Agarose, allowing the eluate to be concentrated without denaturation. The eluted protein bound [ 125 I]mannose-BSA in a mannan-inhibitable fashion. Microgram quantities of protein were isolated in this fashion. SDS-PAGE revealed a major protein band at 175kD. Amino acid analysis indicates low concentrations of methionine. Results from concanavalin A binding studies and endoglycosidase F digestion suggest that the mannose receptor is a glycoprotein containing N-linked oligosaccharides

  17. Comparison of two different segmentation methods on planar lung perfusion scan with reference to quantitative value on SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Min Seok; Kang, Yeon Koo; Ha, Seung Gyun [Dept. of Nuclear Medicine, Seoul National University Hospital, Seoul (Korea, Republic of); and others

    2017-06-15

    Until now, there was no single standardized regional segmentation method of planar lung perfusion scan. We compared planar scan based two segmentation methods, which are frequently used in the Society of Nuclear Medicine, with reference to the lung perfusion single photon emission computed tomography (SPECT)/computed tomography (CT) derived values in lung cancer patients. Fifty-five lung cancer patients (male:female, 37:18; age, 67.8 ± 10.7 years) were evaluated. The patients underwent planar scan and SPECT/CT after injection of technetium-99 m macroaggregated albumin (Tc-99 m-MAA). The % uptake and predicted postoperative percentage forced expiratory volume in 1 s (ppoFEV1%) derived from both posterior oblique (PO) and anterior posterior (AP) methods were compared with SPECT/CT derived parameters. Concordance analysis, paired comparison, reproducibility analysis and spearman correlation analysis were conducted. The % uptake derived from PO method showed higher concordance with SPECT/CT derived % uptake in every lobe compared to AP method. Both methods showed significantly different lobar distribution of % uptake compared to SPECT/CT. For the target region, ppoFEV1% measured from PO method showed higher concordance with SPECT/CT, but lower reproducibility compared to AP method. Preliminary data revealed that every method significantly correlated with actual postoperative FEV1%, with SPECT/CT showing the best correlation. The PO method derived values showed better concordance with SPECT/CT compared to the AP method. Both PO and AP methods showed significantly different lobar distribution compared to SPECT/CT. In clinical practice such difference according to different methods and lobes should be considered for more accurate postoperative lung function prediction.

  18. Regulation of rabbit lung cytochrome P-450 prostaglandin omega-hydroxylase (P-450/sub PG-omega/) during pregnancy

    International Nuclear Information System (INIS)

    Muerhoff, A.S.; Williams, D.E.; Jackson, V.; Leithauser, M.T.; Waterman, M.R.; Johnson, E.F.; Masters, B.S.S.

    1987-01-01

    The mechanism of induction during pregnancy of a rabbit lung prostaglandin omega-hydroxylase cytochrome P-450 has been investigated. This activity has been demonstrated to be induced over 100-fold in 28-day pregnant rabbits, as compared to nonpregnant rabbits. The induction is reflected by an increase in the amount of P-450/sub PG-omega/ protein as measured by Western blotting. P-450/sub PG-omega/ microsomal protein increases throughout gestation concomitant with an increase in PGE 1 omega-hydroxylase activity. Elucidation of the level of induction involved extraction of RNA from rabbit lungs obtained at various days of gestation followed by in vitro translation of the RNA in the presence of 35 S-methionine. Immunoprecipitation of newly synthesized P-450 and analysis of the immunoisolates by SDS-PAGE, autoradiography and densitometry of the P-450/sub PG-omega/ band revealed that the P-450/sub PG-omega/ mRNA levels followed the gestational time-dependent increase observed for both PGE 1 omega-hydroxylase activity and P-450/sub PG-omega/ protein, i.e., a gradual increase peaking at 28-days, dropping precipitously to near control levels following parturition. These data suggest that control of P-450/sub PG-omega expression occurs at the transcriptional level. Western blots of human lung bronchioloalveolar-carcinoma cell lines NCL-H322 and NCL-H358 utilizing a guinea pig IgG to P-450/sub PG-omega/ detect a cross-reactive species

  19. Myocardial visualization on a routine perfusion lung scintigram: Relationship to the amount of right-to-left shunt

    International Nuclear Information System (INIS)

    Seto, H.; Futatsuya, R.; Kamei, T.; Kakishita, M.; Hisada, K.

    1983-01-01

    Three cases of myocardial visualization on a routine perfusion lung scintigram with sup(99m)Tc-macroaggregaed albumin were reported in patients with congenital heart diseases; two cases of tetralogy of Fallot and one case of truncus arteriosus type IV. Large right-to-left shunts greater than 39% and marked hypertrophy of the ventricle suggesting the presence of increased coronary blood flow were noted in all cases. In the two patients with tetralogy of Fallot myocardial activity appeared to be located in the hypertrophic right venticles. (orig.)

  20. Myocardial visualization on a routine perfusion lung scintigram: Relationship to the amount of right-to-left shunt

    Energy Technology Data Exchange (ETDEWEB)

    Seto, H.; Futatsuya, R.; Kamei, T.; Kakishita, M.; Hisada, K.

    1983-11-14

    Three cases of myocardial visualization on a routine perfusion lung scintigram with sup(99m)Tc-macroaggregated albumin were reported in patients with congenital heart diseases; two cases of tetralogy of Fallot and one case of truncus arteriosus type IV. Large right-to-left shunts greater than 39% and marked hypertrophy of the ventricle suggesting the presence of increased coronary blood flow were noted in all cases. In the two patients with tetralogy of Fallot myocardial activity appeared to be located in the hypertrophic right venticles.

  1. A potential to reduce pulmonary toxicity: The use of perfusion SPECT with IMRT for functional lung avoidance in radiotherapy of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lavrenkov, Konstantin; Christian, Judith A.; Partridge, Mike; Niotsikou, Elena; Cook, Gary; Parker, Michelle; Bedford, James L.; Brada, Michael

    2007-01-01

    Background and purpose: The study aimed to examine specific avoidance of functional lung (FL) defined by a single photon emission computerized tomography (SPECT) lung perfusion scan, using intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3-DCRT) in patients with non-small cell lung cancer (NSCLC). Materials and methods: Patients with NSCLC underwent planning computerized tomography (CT) and lung perfusion SPECT scan in the treatment position using fiducial markers to allow co-registration in the treatment planning system. Radiotherapy (RT) volumes were delineated on the CT scan. FL was defined using co-registered SPECT images. Two inverse coplanar RT plans were generated for each patient: 4-field 3-DCRT and 5-field step-and-shoot IMRT. 3-DCRT plans were created using automated AutoPlan optimisation software, and IMRT plans were generated employing Pinnacle 3 treatment planning system (Philips Radiation Oncology Systems). All plans were prescribed to 64 Gy in 32 fractions using data for the 6 MV beam from an Elekta linear accelerator. The objectives for both plans were to minimize the volume of FL irradiated to 20 Gy (fV 20 ) and dose variation within the planning target volume (PTV). A spinal cord dose was constrained to 46 Gy. Volume of PTV receiving 90% of the prescribed dose (PTV 90 ), fV 20 , and functional mean lung dose (fMLD) were recorded. The PTV 90 /fV 20 ratio was used to account for variations in both measures, where a higher value represented a better plan. Results: Thirty-four RT plans of 17 patients with stage I-IIIB NSCLC suitable for radical RT were analysed. In 6 patients with stage I-II disease there was no improvement in PTV 90 , fV 20 , PTV/fV 20 ratio and fMLD using IMRT compared to 3-DCRT. In 11 patients with stage IIIA-B disease, the PTV was equally well covered with IMRT and 3-DCRT plans, with IMRT producing better PTV 90 /fV 20 ratio (mean ratio - 7.2 vs. 5.3, respectively, p = 0.001) and reduced f

  2. Triphasic contrast injection improves evaluation of dual energy lung perfusion in pulmonary CT angiography

    International Nuclear Information System (INIS)

    Kerl, J. Matthias; Bauer, Ralf W.; Renker, Matthias; Weber, Eva; Weisser, Philipp; Korkusuz, Huedayi; Schell, Boris; Larson, Maya Christina; Kromen, Wolfgang; Jacobi, Volkmar

    2011-01-01

    Purpose: Lung perfusion analysis at dual energy CT (DECT) is sensitive to beam hardening artifacts from dense contrast material (CM). We compared two scan and four CM injection protocols in terms of severity of artifacts and attenuation levels in the thoracic vessels. Methods and materials: Data of 120 patients who had undergone dual source dual energy CT pulmonary angiography for suspected acute pulmonary embolism were evaluated. Group 1 (n = 30) was scanned in craniocaudal direction using 64 × 0.6 mm collimation; groups 2–4 (n = 30 each) were scanned in caudocranial direction using 14 × 1.2 mm collimation. In groups 1–3 biphasic injection protocols with different amounts of CM and NaCl were investigated. In group 4 a split-bolus protocol with an initial CM bolus of 50 ml followed by 30 ml of a 70%:30% NaCl/CM mixture and a 50 ml NaCl chaser bolus was used. CT density values in the subclavian vein (SV), superior vena cava (SVC), pulmonary artery tree (PA), and the descending aorta (DA) were measured. Artifacts arising from the SV and SVC on DE pulmonary iodine distribution map were rated on a scale from 1 to 5 (1 = fully diagnostic; 5 = non-diagnostic) by two blinded readers. Results: In protocol 4 mean attenuation in the SV (645 ± 158 HU) and SVC (389 ± 114 HU) were significantly lower compared to groups 1–3 (p < 0.002). Artifacts in group 4 (1.1 ± 0.4 and 1.5 ± 0.7 for the SV and SVC, respectively) were rated significantly less severe compared to group 1 (3.2 ± 1.0 and 3.0 ± 1.1), 2 (2.6 ± 1.1 and 2.3 ± 1.0) and 3 (1.9 ± 0.9 and 1.9 ± 0.7) (p < 0.01 for all), whereas no significant difference was found between groups 1 and 2 for the subclavian vein (p = 0.07). Attenuation in the PA was also significantly lower in group 4 (282 ± 116 HU) compared to group 1 (397 ± 137 HU), group 2 (376 ± 115 HU) and group 3 (311 ± 104 HU), but still on a diagnostic level. Conclusion: Split-bolus injection provides sufficient attenuation for pulmonary DECT

  3. 111Indium-labeled neutrophil migration into the lungs of bleomycin-treated rabbits assessed noninvasively by external scintigraphy

    International Nuclear Information System (INIS)

    Haslett, C.; Shen, A.S.; Feldsien, D.C.; Allen, D.; Henson, P.M.; Cherniack, R.M.

    1989-01-01

    Factors controlling neutrophil migration into the lung are poorly understood, but their identification is important for our understanding of the pathogenesis of inflammatory lung diseases. Pulmonary inflammation is difficult to quantify, and neutrophils in tissues and BAL may not accurately represent cell migration. In this study, intravenously delivered pulses of rabbit neutrophils labeled with Indium-111 (111In-neutrophils) were used to monitor neutrophil migration into the lungs. Radioactivity quantified in the lung region of interest (ROI) of external gamma camera scintigrams recorded 24 h after intravenous 111In-neutrophil injection accurately reflected the actual neutrophil-associated lung tissue radioactivity. ROI radioactivity at 24 h also correlated closely with the percent of 111In-neutrophils that had migrated into lavageable air spaces, and this parameter therefore provided an index of total lung 111In-neutrophil migration. Using 24-h ROI radioactivity and percent of injected 111In-neutrophils recovered in BAL at 24 h as indices of neutrophil migration into the lung, it was found that intratracheal saline caused only a transient neutrophil migration, whereas 10 U/kg intratracheal bleomycin induced migration that persisted for as long as 3 wk. 111In-neutrophil migration into the lung, assessed by external scintigraphy, correlated with total neutrophils quantified in histologic sections (r = 0.71, p = 0.006). The data suggest that this approach will be valuable in investigating mechanisms controlling neutrophil migration in lung inflammation, and that 111In-neutrophil scintigraphy may provide a noninvasive index of total lung neutrophil load that might be useful in staging inflammation in patchy diseases such as idiopathic pulmonary fibrosis

  4. Estimation of pulmonary hypertension by perfusion lung scintigraphy: Gravitational effect of postural changes between the lateral decubitus positions

    International Nuclear Information System (INIS)

    Tanaka, Masao; Fujii, Tadashige; Hirayama, Jiro; Okubo, Shinichi; Sekiguchi, Morie

    1990-01-01

    To estimate pulmonary hypertension in patients with various heart diseases, we devised a new method using perfusion lung scintigraphy with 99m Tc-labelled macroaggregated albumin. In this method, changes in the distribution of pulmonary perfusion caused by gravitational effects, namely, changes in the total count ratios of the right lung against the left lung between right and left lateral decubitus positions (rt/lt), were assessed in 62 patients and in 10 normal subjects. The rt/lt ratios were calculated as indices of the above changes. They correlated significantly with mean pulmonary arterial pressure (mPAP) (γ=-0.62, P<0.001), pulmonary capillary wedge pressure (γ=-0.63, P<0.001) and pulmonary arteriolar resistance (γ=0.50, P<0.001) in all subjects. In 17 patients with valvular heart diseases, the ratio correlated significantly with mPAP (γ=-0.84, P<0.001). In 10 patients with various heart diseases, the U/S ratio, i.e. the index of changes in the count ratios of the upper field against the lower field for the right lung following postural change from the uprigth to the supine position, was also obtained as well as the rt/lt ratio. The latter evidenced a better correlation with mPAP (γ=-0.90, P<0.001) than the former (γ=-0.64, P<0.05). We conclude that this method is valuable as a noninvasive approach for the estimation of pulmonary hypertension. (orig.)

  5. Loss of lung function after chemo-radiotherapy for NSCLC measured by perfusion SPECT/CT: Correlation with radiation dose and clinical morbidity

    DEFF Research Database (Denmark)

    Farr, Katherina P; Møller, Ditte S; Khalil, Azza A

    2015-01-01

    BACKGROUND: The purpose of the study was to assess dose and time dependence of radiotherapy (RT)-induced changes in regional lung function measured with single photon emission computed tomography (SPECT) of the lung and relate these changes to the symptomatic endpoint of radiation pneumonitis (RP......) in patients treated for non-small cell lung cancer (NSCLC). MATERIAL AND METHODS: NSCLC patients scheduled to receive curative RT of minimum 60 Gy were included prospectively in the study. Lung perfusion SPECT/CT was performed before and three months after RT. Reconstructed SPECT/CT data were registered...

  6. Converging stereotactic radiotherapy using kilovoltage X-rays: experimental irradiation of normal rabbit lung and dose-volume analysis with Monte Carlo simulation.

    Science.gov (United States)

    Kawase, Takatsugu; Kunieda, Etsuo; Deloar, Hossain M; Tsunoo, Takanori; Seki, Satoshi; Oku, Yohei; Saitoh, Hidetoshi; Saito, Kimiaki; Ogawa, Eileen N; Ishizaka, Akitoshi; Kameyama, Kaori; Kubo, Atsushi

    2009-10-01

    To validate the feasibility of developing a radiotherapy unit with kilovoltage X-rays through actual irradiation of live rabbit lungs, and to explore the practical issues anticipated in future clinical application to humans through Monte Carlo dose simulation. A converging stereotactic irradiation unit was developed, consisting of a modified diagnostic computed tomography (CT) scanner. A tiny cylindrical volume in 13 normal rabbit lungs was individually irradiated with single fractional absorbed doses of 15, 30, 45, and 60 Gy. Observational CT scanning of the whole lung was performed every 2 weeks for 30 weeks after irradiation. After 30 weeks, histopathologic specimens of the lungs were examined. Dose distribution was simulated using the Monte Carlo method, and dose-volume histograms were calculated according to the data. A trial estimation of the effect of respiratory movement on dose distribution was made. A localized hypodense change and subsequent reticular opacity around the planning target volume (PTV) were observed in CT images of rabbit lungs. Dose-volume histograms of the PTVs and organs at risk showed a focused dose distribution to the target and sufficient dose lowering in the organs at risk. Our estimate of the dose distribution, taking respiratory movement into account, revealed dose reduction in the PTV. A converging stereotactic irradiation unit using kilovoltage X-rays was able to generate a focused radiobiologic reaction in rabbit lungs. Dose-volume histogram analysis and estimated sagittal dose distribution, considering respiratory movement, clarified the characteristics of the irradiation received from this type of unit.

  7. Effects of Conventional Mechanical Ventilation Performed by Two Neonatal Ventilators on the Lung Functions of Rabbits with Meconium-Induced Acute Lung Injury

    Directory of Open Access Journals (Sweden)

    Mokra D

    2016-12-01

    Full Text Available Severe meconium aspiration syndrome (MAS in the neonates often requires a ventilatory support. As a method of choice, a conventional mechanical ventilation with small tidal volumes (VT<6 ml/kg and appropriate ventilatory pressures is used. The purpose of this study was to assess the short-term effects of the small-volume CMV performed by two neonatal ventilators: Aura V (Chirana Stara Tura a.s., Slovakia and SLE5000 (SLE Ltd., UK on the lung functions of rabbits with experimentally-induced MAS and to estimate whether the newly developed neonatal version of the ventilator Aura V is suitable for ventilation of the animals with MAS.

  8. Pulmonary perfusion ''without ventilation''

    International Nuclear Information System (INIS)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-01-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  9. Relative preservation of peripheral lung function in smoking-related pulmonary emphysema: assessment with {sup 99m}Tc-MAA perfusion and dynamic {sup 133}Xe SPET

    Energy Technology Data Exchange (ETDEWEB)

    Suga, Kazuyoshi; Kume, Norihiko; Matsunaga, Naofumi; Ogasawara, Nobuhiko; Motoyama, Kazumi; Hara, Akiko; Matsumoto, Tsuneo [Department of Radiology, Yamaguchi University School of Medicine, Ube, Yamaguchi (Japan)

    2000-07-01

    In this study the cross-sectional functional differences between the central and peripheral lung in smokers with pulmonary emphysema were evaluated by lung perfusion and dynamic xenon-133 single-photon emission tomography (SPET). The subjects were 81 patients with a long-term smoking history and relatively advanced emphysema, 17 non-smoker patients with non-obstructive lung diseases and six healthy non-smokers. Regional lung functional difference between the peripheral and central lung was assessed in the upper, middle and lower lung zones by technetium-99m macroaggregated albumin SPET and dynamic {sup 133}Xe SPET. The distribution of emphysematous changes was assessed by density-mask computed tomography (CT) images which depicted abnormally low attenuation areas (LAAs) of less than -960 Hounsfield units. Two hundred and eighty-eight (59.2%) lung zones of 63 (77.7%) patients with pulmonary emphysema showed relative preservation of lung function in the peripheral lung, with a curvilinear band of normal perfusion (a stripe sign) and a significantly faster {sup 133}Xe half-clearance time (T{sub 1/2}) than in central lung (P<0.0001). Of these lung zones, 256 (88.8%) showed central-dominant LAA distributions on density-mask CT images, but the remaining 32 zones did not show any regional preference in LAA distribution. Conversely, 117 (24.0%) lung zones of 19 (23.4%) patients showed periphery-dominant perfusion defects and LAA distributions, with significantly prolonged T{sub 1/2} in the peripheral lung area (P<0.0001). The remaining 81 lung zones of the patients with pulmonary emphysema and all the lung zones of the healthy subjects and patients with non-obstructive lung diseases did not show a stripe sign, and no differences were observed in T{sub 1/2} values and LAA distributions between the central and peripheral lung. Relative preservation of peripheral lung function seems to be a characteristic feature in smoking-related pulmonary emphysema, and may indicate a

  10. Information for the diagnosis of broncho-pulmonary diseases obtained by the combined use of perfusion lung scintigraphy and selective bronchial arteriography

    International Nuclear Information System (INIS)

    Wouamba Foning, Michel.

    1976-01-01

    Our study is limited to perfusion lung scintigraphy and deals with the following in turn: - radioisotopes and their conditioning, - detection and recording equipment, - results and limits of the method. The tracers used here were radioiodine-labelled human albumin macro-aggregates and more especially technetium-labelled microspheres. Scintigraphy, which visualizes or charts the local distribution of radioactive indicators, is carried out with two kinds of apparatus, scanners and scintillation cameras. The information acquired may be accurately analysed at the same time owing to modern data processing systems. The interpretation of radiotracer lung transit curves made by several authors is not very useful for our work, consequently we have kept to the analysis of images obtained by the Anger camera or similar instruments. The Anger scintillation camera seems to be well suited to isotopic lung exploration providing morphological and functional data simultaneously. Perfusion lung scintigraphy, which reflects the quality of lung circulation at the capillary level, appears to be a valuable asset in the diagnostic approach to certain chest X-ray images. The technique is fast, painless, neat, harmless and almost never contra-indicated. However like other techniques it cannot solve every problem on its own. Under these conditions, we must admit, on weighing up the results of this study, that perfusion lung scintigraphy had to be followed in most cases by selective bronchial arteriography [fr

  11. Assessment of regional lung functional impairment with co-registered respiratory-gated ventilation/perfusion SPET-CT images: initial experiences

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Yasuhiko, Kawakami; Zaki, Mohammed; Yamashita, Tomio; Seto, Aska; Matsumoto, Tsuneo; Matsunaga, Naofumi

    2004-01-01

    In this study, respiratory-gated ventilation and perfusion single-photon emission tomography (SPET) were used to define regional functional impairment and to obtain reliable co-registration with computed tomography (CT) images in various lung diseases. Using a triple-headed SPET unit and a physiological synchroniser, gated perfusion SPET was performed in a total of 78 patients with different pulmonary diseases, including metastatic nodules (n=15); in 34 of these patients, it was performed in combination with gated technetium-99m Technegas SPET. Projection data were acquired using 60 stops over 120 for each detector. Gated end-inspiration and ungated images were reconstructed from 1/8 data centered at peak inspiration for each regular respiratory cycle and full respiratory cycle data, respectively. Gated images were registered with tidal inspiration CT images using automated three-dimensional (3D) registration software. Registration mismatch was assessed by measuring 3D distance of the centroid of the nine selected round perfusion-defective nodules. Gated SPET images were completed within 29 min, and increased the number of visible ventilation and perfusion defects by 9.7% and 17.2%, respectively, as compared with ungated images; furthermore, lesion-to-normal lung contrast was significantly higher on gated SPET images. In the nine round perfusion-defective nodules, gated images yielded a significantly better SPET-CT match compared with ungated images (4.9±3.1 mm vs 19.0±9.1 mm, P<0.001). The co-registered SPET-CT images allowed accurate perception of the location and extent of each ventilation/perfusion defect on the underlying CT anatomy, and characterised the pathophysiology of the various diseases. By reducing respiratory motion effects and enhancing perfusion/ventilation defect clarity, gated SPET can provide reliable co-registered images with CT images to accurately characterise regional functional impairment in various lung diseases. (orig.)

  12. Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

    Science.gov (United States)

    Froeling, Vera; Heimann, Uwe; Huebner, Ralf-Harto; Kroencke, Thomas J; Maurer, Martin H; Doellinger, Felix; Geisel, Dominik; Hamm, Bernd; Brenner, Winfried; Schreiter, Nils F

    2015-07-01

    To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.

  13. Phenylbutyrate counteracts Shigella mediated downregulation of cathelicidin in rabbit lung and intestinal epithelia: a potential therapeutic strategy.

    Directory of Open Access Journals (Sweden)

    Protim Sarker

    Full Text Available BACKGROUND: Cathelicidins and defensins are endogenous antimicrobial peptides (AMPs that are downregulated in the mucosal epithelia of the large intestine in shigellosis. Oral treatment of Shigella infected rabbits with sodium butyrate (NaB reduces clinical severity and counteracts the downregulation of cathelicidin (CAP-18 in the large intestinal epithelia. AIMS: To develop novel regimen for treating infectious diseases by inducing innate immunity, we selected sodium 4-phenylbutyrate (PB, a registered drug for a metabolic disorder as a potential therapeutic candidate in a rabbit model of shigellosis. Since acute respiratory infections often cause secondary complications during shigellosis, the systemic effect of PB and NaB on CAP-18 expression in respiratory epithelia was also evaluated. METHODS: The readouts were clinical outcomes, CAP-18 expression in mucosa of colon, rectum, lung and trachea (immunohistochemistry and real-time PCR and release of the CAP-18 peptide/protein in stool (Western blot. PRINCIPAL FINDINGS: Significant downregulation of CAP-18 expression in the epithelia of rectum and colon, the site of Shigella infection was confirmed. Interestingly, reduced expression of CAP-18 was also noticed in the epithelia of lung and trachea, indicating a systemic effect of the infection. This suggests a causative link to acute respiratory infections during shigellosis. Oral treatment with PB resulted in reduced clinical illness and upregulation of CAP-18 in the epithelium of rectum. Both PB and NaB counteracted the downregulation of CAP-18 in lung epithelium. The drug effect is suggested to be systemic as intravenous administration of NaB could also upregulate CAP-18 in the epithelia of lung, rectum and colon. CONCLUSION: Our results suggest that PB has treatment potential in human shigellosis. Enhancement of CAP-18 in the mucosal epithelia of the respiratory tract by PB or NaB is a novel discovery. This could mediate protection from

  14. Phenylbutyrate counteracts Shigella mediated downregulation of cathelicidin in rabbit lung and intestinal epithelia: a potential therapeutic strategy.

    Science.gov (United States)

    Sarker, Protim; Ahmed, Sultan; Tiash, Snigdha; Rekha, Rokeya Sultana; Stromberg, Roger; Andersson, Jan; Bergman, Peter; Gudmundsson, Gudmundur H; Agerberth, Birgitta; Raqib, Rubhana

    2011-01-01

    Cathelicidins and defensins are endogenous antimicrobial peptides (AMPs) that are downregulated in the mucosal epithelia of the large intestine in shigellosis. Oral treatment of Shigella infected rabbits with sodium butyrate (NaB) reduces clinical severity and counteracts the downregulation of cathelicidin (CAP-18) in the large intestinal epithelia. To develop novel regimen for treating infectious diseases by inducing innate immunity, we selected sodium 4-phenylbutyrate (PB), a registered drug for a metabolic disorder as a potential therapeutic candidate in a rabbit model of shigellosis. Since acute respiratory infections often cause secondary complications during shigellosis, the systemic effect of PB and NaB on CAP-18 expression in respiratory epithelia was also evaluated. The readouts were clinical outcomes, CAP-18 expression in mucosa of colon, rectum, lung and trachea (immunohistochemistry and real-time PCR) and release of the CAP-18 peptide/protein in stool (Western blot). Significant downregulation of CAP-18 expression in the epithelia of rectum and colon, the site of Shigella infection was confirmed. Interestingly, reduced expression of CAP-18 was also noticed in the epithelia of lung and trachea, indicating a systemic effect of the infection. This suggests a causative link to acute respiratory infections during shigellosis. Oral treatment with PB resulted in reduced clinical illness and upregulation of CAP-18 in the epithelium of rectum. Both PB and NaB counteracted the downregulation of CAP-18 in lung epithelium. The drug effect is suggested to be systemic as intravenous administration of NaB could also upregulate CAP-18 in the epithelia of lung, rectum and colon. Our results suggest that PB has treatment potential in human shigellosis. Enhancement of CAP-18 in the mucosal epithelia of the respiratory tract by PB or NaB is a novel discovery. This could mediate protection from secondary respiratory infections that frequently are the lethal causes in

  15. Accuracy and Utility of Deformable Image Registration in 68Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Hofman, Michael S.; Hicks, Rodney J.; Callahan, Jason; Kron, Tomas; MacManus, Michael P.; Ball, David L.; Jackson, Price; Siva, Shankar

    2015-01-01

    Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: 68 Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration. Conclusions

  16. Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hardcastle, Nicholas, E-mail: nick.hardcastle@gmail.com [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne (Australia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong (Australia); Hofman, Michael S. [Molecular Imaging, Centre for Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne (Australia); Hicks, Rodney J. [Molecular Imaging, Centre for Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne (Australia); Department of Medicine, University of Melbourne, Melbourne (Australia); Callahan, Jason [Molecular Imaging, Centre for Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne (Australia); Kron, Tomas [Department of Medical Imaging and Radiation Sciences, Monash University, Clayton (Australia); The Sir Peter MacCallum Department of Oncology, Melbourne University, Victoria (Australia); MacManus, Michael P.; Ball, David L. [Division of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia); The Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne (Australia); Jackson, Price [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne (Australia); Siva, Shankar [Division of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne (Australia)

    2015-09-01

    Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration

  17. Bioevaluation study of {sup 32}P-CP-PLLA particle brachytherapy in a rabbit VX2 lung tumor model

    Energy Technology Data Exchange (ETDEWEB)

    Xu Yuping [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, 20 Qianrong Road, Wuxi 214063 (China); Yang Min, E-mail: ymzfk@yahoo.com.hk [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, 20 Qianrong Road, Wuxi 214063 (China); Pan Donghui; Wang Lizhen [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, 20 Qianrong Road, Wuxi 214063 (China); Liu Lu; Huang Peilin [Nuclear Medicine Institute of Southeast University, Nanjing 210009 (China); Shao Guoqiang [Department of Nuclear Medicine, Nanjing First Hospital Affiliated to Nanjing University, Nanjing 210006 (China)

    2012-04-15

    Objective: The purpose of this study was to investigate the therapy effects of intratumoral administration of {sup 32}P-CP-PLLA particles in a rabbit VX2 lung tumor model. Methods: 16 rabbits with tumors were randomly divided into 4 groups. 4 rabbits served as untreated controls, and others received intratumoral administration of {sup 32}P-CP-PLLA particles with CT guidance. The total radioactivities in treated groups were as follows: a low activity was 93 MBq (n=4) (group 1), a medium activity was 185 MBq (n=4) (group 2) and a high activity was 370 MBq (n=4) (group 3). Brachytherapy treated VX2 tumors underwent {sup 18}F-FDG PET/CT at 0 day, 3 day, 7 day and 14 day postinjection. In control group, {sup 18}F-FDG PET/CT images were acquired at the same time points but without any treatment. Bremsstrahlung SPECT images were performed at 14 days after intratumoral brachytherapy in treated groups. After Bremsstrahlung SPECT and last {sup 18}F-FDG PET/CT imagings, the rabbits were euthanized and the tumors were removed for histological examination. Results: Bremsstrahlung SPECT images study indicated that there was no leakage of {sup 32}P out of the injection site at 14 days after treatment. Compared with the control, the tumor volumes in treated groups significantly decreased, and {sup 32}P-CP-PLLA particle produced a reduction in maximum or mean SUV of VX2 tumor (p<0.05). The percentage changes in maximum and mean SUV gradually decreased in group 1 and group 2 from day 3 to day 14 (p<0.05). A transient increase in {sup 18}F-FDG accumulation at group 3 occurred due to the inflammatory reaction elements. Activity dependence was seen in HE and PCNA staining after 14 days treatment among three treated groups (p<0.05). Conclusions: Our data suggested that {sup 32}P-CP-PLLA particle localized on the injecting sites. This novel brachytherapy device efficiently suppressed the growth of the VX2 tumors implanted in the rabbit. - Highlights: Black-Right-Pointing-Pointer {sup 32

  18. Phosphodiesterase-4 inhibition combined with isoniazid treatment of rabbits with pulmonary tuberculosis reduces macrophage activation and lung pathology.

    Science.gov (United States)

    Subbian, Selvakumar; Tsenova, Liana; O'Brien, Paul; Yang, Guibin; Koo, Mi-Sun; Peixoto, Blas; Fallows, Dorothy; Zeldis, Jerome B; Muller, George; Kaplan, Gilla

    2011-07-01

    Tuberculosis (TB) is responsible for significant morbidity and mortality worldwide. Even after successful microbiological cure of TB, many patients are left with residual pulmonary damage that can lead to chronic respiratory impairment and greater risk of additional TB episodes due to reinfection with Mycobacterium tuberculosis. Elevated levels of the proinflammatory cytokine tumor necrosis factor-α and several other markers of inflammation, together with expression of matrix metalloproteinases, have been associated with increased risk of pulmonary fibrosis, tissue damage, and poor treatment outcomes in TB patients. In this study, we used a rabbit model of pulmonary TB to evaluate the impact of adjunctive immune modulation, using a phosphodiesterase-4 inhibitor that dampens the innate immune response, on the outcome of treatment with the antibiotic isoniazid. Our data show that cotreatment of M. tuberculosis infected rabbits with the phosphodiesterase-4 inhibitor CC-3052 plus isoniazid significantly reduced the extent of immune pathogenesis, compared with antibiotic alone, as determined by histologic analysis of infected tissues and the expression of genes involved in inflammation, fibrosis, and wound healing in the lungs. Combined treatment with an antibiotic and CC-3052 not only lessened disease but also improved bacterial clearance from the lungs. These findings support the potential for adjunctive immune modulation to improve the treatment of pulmonary TB and reduce the risk of chronic respiratory impairment. Copyright © 2011 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  19. Study on incidence of pulmonary embolism in patients with cardiac pacemakers using lung perfusion mapping and ventilation scanning

    International Nuclear Information System (INIS)

    Yamashina, Hideki; Higo, Masanori; Sueda, Takashi

    1990-01-01

    We investigated pulmonary perfusion mapping and ventilation scanning employing 99mTC-MMA and 81mKr-Gas in patients with DDD and VVI cardiac pacemaker implantation. In 51 cases among 175 patients we observed some defects which matched the results from lung perfusion scanning in the pulmonary segments and sub-segments. These were diagnosed as pulmonary embolism after the possibility of other pulmonary diseases was rejected. The incidence rate of pulmonary embolism in patients with VVI (Ventricular pacing/sensing, inhibited type) pacemakers was 47 out of 138, or 34.1%, especially for those who received a pulmonary scanning examination whithin 6 months after pacemaker implantation. In contrast, those who were examined after 6 months had lower rates as well as chronological factors. The incidence rate of pulmonary embolism in 37 patients with DDD (Double chamber pacing/sensing, double modes of response) pacemakers was 10.8%, considerably lower than that for patients with VVI pacemakers. Therefore, one main factor of pulmonary embolism in patients with pacemakers could be the non-physiological phase of the contractions of both atria and ventricles. Other factors, such as the presence of foreign bodies in the endocardium, aging, and hypertension, could also promote pulmonary embolism. (author)

  20. Significance of single ventilation/perfusion mismatches in krypton-81m/technetium-99m lung scintigraphy

    International Nuclear Information System (INIS)

    Rosen, J.M.; Palestro, C.J.; Markowitz, D.; Alderson, P.O.

    1986-01-01

    The significance of a single area of ventilation/perfusion (V/P) mismatch in lung scans performed on patients suspected of pulmonary embolism (PE) was evaluated. Ten of 20 patients with this scan finding were found to have PE. An intermediate probability of PE was found with segmental (71%) or subsegmental (45%) single V/P mismatches. Seven of 16 patients with a single V/P mismatch and without a matching radiographic opacity had PE. Three of the four patients who had a V/P mismatch and a matching radiographic opacity were found to have PE. Multiview ventilation imaging with 81mKr was found to have advantages for the evaluation of single V/P mismatches. Based on the data available at this time, a single V/P mismatch suggests an intermediate probability of PE

  1. Time Course of Changes in Extravascular Lung Water Index, Intracranial and Cerebral Perfusion Pressures in Acute Cerebral Circulatory Disorders

    Directory of Open Access Journals (Sweden)

    Yu. A. Churlyaev

    2009-01-01

    Full Text Available Objective: to study the time course of changes in extravascular lung water index (ELWI and intracranial and cerebral perfusion pressures (ICP and CPP and to determine their possible relationships in acute cerebral circulatory disorders (ACCD. Subject and methods. ELWI, pulmonary vascular permeability index (PVPI, ICP, CPP, and central hemodynamics were studied by transpulmonary thermodilution and current X-ray studies were conducted in 18 patients on days 1, 3, 5, and 7 of ACCD. Results. Examinations revealed a supratentorial dislocation of the brain in 6 persons; its subtento-rial dislocation was found in 1 case; supra- and subtentorial dislocations were seen in 6. In patients, ELWI and PVPI increased from days 1 and 5, respectively. The high baseline ICP increased over time. CPP remained unchanged. Preserved left ventricular contractility, enhanced myocardial one, a significant direct correlation between ELWI and PVPI, as well as their increase confirmed that the noncardiogenic genesis was responsible for increased ELWI. A direct significant correlation was found between ICP and ELWI, ICP and PVPI. Against this background, acute respiratory distress syndrome developed in 14 patients with pneumonia evolving in its presence in 7 patients. Conclusion. In ACCD, ELWI increases in the first 24 hours of the acute period. One of its causes is, along with others, primary and/or secondary damage to the brainstem structures with elevated ICP and progressive brain dislocation. The determination of ICP, unlike CPP, is crucial in the diagnosis and treatment of primary/secondary brain injuries and in prognosis. Key words: acute cerebral circulatory disorder, extravascular lung fluid, pulmonary vascular permeability, intracranial pressure, cerebral perfusion pressure, acute respiratory distress syndrome.

  2. Intravoxel Incoherent Motion Diffusion Weighted MR Imaging for Monitoring the Instantly Therapeutic Efficacy of Radiofrequency Ablation in Rabbit VX2 Tumors without Evident Links between Conventional Perfusion Weighted Images.

    Directory of Open Access Journals (Sweden)

    Ziyi Guo

    Full Text Available To investigate the intravoxel incoherent motion diffusion weighted imaging (IVIM-DWI as a potential valuable marker to monitor the therapy responses of VX2 to radiofrequency ablation (RF Ablation.The institutional animal care and use committee approved this study. In 10 VX2 tumor-bearing rabbits, IVIM-DWI examinations were performed with a 3.0T imaging unit by using 16 b values from 0 to 800 sec/mm2. The true diffusion coefficient (D, pseudodiffusion coefficient (D* and perfusion fraction (f of tumors were compared between before and instantly after RF Ablation treatment. The differences of D, D* and f and conventional perfusion parameters (from perfusion CT and dynamic enhanced magnetic resonance imaging, DCE-MRI in the coagulation necrosis area, residual unablated area, untreated area, and normal control had been calculated by compared t-test. The correlation between f or D* with perfusion weighted CT including blood flow, BF (milliliter per 100 mL/min, blood volume, BV (milliliter per 100 mL/min, and capillary permeability-surface area, PMB (as a fraction or from DCE-MRI: transfer constant (Ktrans, extra-vascular extra-cellular volume fraction (Ve and reflux constant (Kep values had been analyzed by region-of-interest (ROI methods to calculate Pearson's correlation coefficients.In the ablated necrosis areas, f and D* significantly decreased and D significantly increased, compared with residual unblazed areas or untreated control groups and normal control groups (P < 0.001. The IVIM-DWI derived f parameters showed significant increases in the residual unablated tumor area. There was no significant correlations between f or D* and conventional perfusion parameters.The IVIM-DW derived f, D and D* parameters have the potential to indicate therapy response immediately after RF Ablation treatment, while no significant correlations with classical tumor perfusion metrics were derived from DCE-MRI and perfusion-CT measurements.

  3. Validation of co-registration of clinical lung ventilation and perfusion SPECT

    International Nuclear Information System (INIS)

    Marsh, S.H.; O'Keeffe, D.S.; Barnden, L.R.

    2010-01-01

    Full text: This talk will present results from a recent validation study of coregistration of computed tomography ventilation and perfusion (SPECT V/Q) images. The coregistration algorithm was incorporated in Qonsub, a program to coregister, normalise and subtract the SPECT (V/Q) images. Ventilation and perfusion image data were acquired from 23 patients undergoing a routine clinical SPECT V/Q study. The only change to normal patient management was the placement of three Tc 9 9 m filled fiducial markers adhered to the skin on the patient's torso. To quantify coregistration accuracy, image data were modified (within software) to remove the markers and Qonsub determined a parameter set of six values fully describing the six degree rigid transformation. The accuracy with which the six parameters coregister the images was then quantified by applying the same transformation parameters to the ventilation markers and determining how well they locate to the perfusion marker positions. Results show that for 65% of patients surveyed co-registration accuracy was to within I pixel, 30% were co-registered with an accuracy between 1 and 2 pixels and 5% were co-registered with an accuracy of between 2 and 3 pixels. Because patient placement between scans resulted in a misregistration of at most five pixels, a more rigorous test of the algorithm was required. Ethics approval had not been sought to intentionally misregister patient images, so the algorithm had to be further tested by synthetically misregistering the images. For these images Qonsub generally co-registered with the same accuracy as the original image. (author)

  4. The role of perfusion lung scanning and diffusion capacity for early diagnosis of micro circulatory disturbances in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Petrova, D.; Shoshlov, P.; Hadjikostova, H.

    2002-01-01

    The development of chronic obstructive pulmonary disease (COPD) and the frequent inflammatory exacerbations with development of respiratory failure lead to changes in the micro circulatory and an increased risk of lung thrombotic and thromboembolic complication. The aim of the study was to establish the possibility of the perfusion lung scanning and diffusion capacity for early diagnosis of pulmonary micro circulatory disturbances in COPD with mild and moderate respiratory failure. 59 COPD patients were investigated. The data presented significant segmental disorders. Only in 5 (8.47%) of them the perfusion lung scintigrams were normal. In 23 of the patients, single-breath diffusing capacity (DICO) and its two components: membranous component (Dm) and capillary blood component (Vc) were determined. DICO was lower especially Vc the mean sign of micro circulatory disorders. A relationship between the degree of hypoxaemia and the changes found in the perfusion scintigraphy was found. Changes in the pulmonary lung scanning and in the diffusion capacity in COPD with mild respiratory failure seem to be an early diagnostic test. The early anticoagulant and desaggregant prevention may decrease the risk of thrombotic complications in the development of the disease. (authors)

  5. Added value of lung perfused blood volume images using dual-energy CT for assessment of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Okada, Munemasa; Kunihiro, Yoshie; Nakashima, Yoshiteru; Nomura, Takafumi; Kudomi, Shohei; Yonezawa, Teppei; Suga, Kazuyoshi; Matsunaga, Naofumi

    2015-01-01

    Purpose: To investigate the added value of lung perfused blood volume (LPBV) using dual-energy CT for the evaluation of intrapulmonary clot (IPC) in patients suspected of having acute pulmonary embolism (PE). Materials and methods: Institutional review board approval was obtained for this retrospective study. Eighty-three patients suspected of having PE who underwent CT pulmonary angiography (CTPA) using a dual-energy technique were enrolled in this study. Two radiologists who were blinded retrospectively and independently reviewed CTPA images alone and the combined images with color-coded LPBV over a 4-week interval, and two separate sessions were performed with a one-month interval. Inter- and intraobserver variability and diagnostic accuracy were evaluated for each reviewer with receiver operating characteristic (ROC) curve analysis. Results: Values for inter- and intraobserver agreement, respectively, were better for CTPA combined with LPBV (ICC = 0.847 and 0.937) than CTPA alone (ICC = 0.748 and 0.861). For both readers, diagnostic accuracy (area under the ROC curve [A z ]) were also superior, when CTPA alone (A z = 0.888 [reader 1] and 0.912 [reader 2]) was compared with that after the combination with LPBV images (A z = 0.966 [reader 1] and 0.959 [reader 2]) (p < 0.001). However, A z values of both images might not have significant difference in statistics, because A z value of CTPA alone was high and 95% confidence intervals overlapped in both images. Conclusion: Addition of dual-energy perfusion CT to CTPA improves detection of peripheral IPCs with better interobserver agreement

  6. Converging Stereotactic Radiotherapy Using Kilovoltage X-Rays: Experimental Irradiation of Normal Rabbit Lung and Dose-Volume Analysis With Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Kawase, Takatsugu; Kunieda, Etsuo; Deloar, Hossain M.; Tsunoo, Takanori; Seki, Satoshi; Oku, Yohei; Saitoh, Hidetoshi; Saito, Kimiaki; Ogawa, Eileen N.; Ishizaka, Akitoshi; Kameyama, Kaori; Kubo, Atsushi

    2009-01-01

    Purpose: To validate the feasibility of developing a radiotherapy unit with kilovoltage X-rays through actual irradiation of live rabbit lungs, and to explore the practical issues anticipated in future clinical application to humans through Monte Carlo dose simulation. Methods and Materials: A converging stereotactic irradiation unit was developed, consisting of a modified diagnostic computed tomography (CT) scanner. A tiny cylindrical volume in 13 normal rabbit lungs was individually irradiated with single fractional absorbed doses of 15, 30, 45, and 60 Gy. Observational CT scanning of the whole lung was performed every 2 weeks for 30 weeks after irradiation. After 30 weeks, histopathologic specimens of the lungs were examined. Dose distribution was simulated using the Monte Carlo method, and dose-volume histograms were calculated according to the data. A trial estimation of the effect of respiratory movement on dose distribution was made. Results: A localized hypodense change and subsequent reticular opacity around the planning target volume (PTV) were observed in CT images of rabbit lungs. Dose-volume histograms of the PTVs and organs at risk showed a focused dose distribution to the target and sufficient dose lowering in the organs at risk. Our estimate of the dose distribution, taking respiratory movement into account, revealed dose reduction in the PTV. Conclusions: A converging stereotactic irradiation unit using kilovoltage X-rays was able to generate a focused radiobiologic reaction in rabbit lungs. Dose-volume histogram analysis and estimated sagittal dose distribution, considering respiratory movement, clarified the characteristics of the irradiation received from this type of unit.

  7. Proliferation during early phases of bronchiolar repair in neonatal rabbits following lung injury by 4-ipomeanol

    International Nuclear Information System (INIS)

    Smiley-Jewell, Suzette M.; Plopper, Charles G.

    2003-01-01

    Nonciliated bronchiolar (Clara cells) are progenitor cells during development. During differentiation, they are more susceptible to injury by environmental toxicants metabolized by the cytochrome P450 monooxygenase system, and injury results in altered bronchiolar repair and development. Squamous cells and abnormal cuboidal epithelium persist into early adulthood. The hypothesis tested in this study was that the failure of bronchiolar epithelium to repair normally in neonates following injury is due to an inhibition of proliferation. A model of differential repair in rabbit kits was used. Proliferation was followed for 1 week post injury in rabbit kits treated with a single dose of the P450-mediated cytotoxicant 4-ipomeanol (IPO) at 7 days old (repair abnormal) and compared to rabbits treated with a single dose of IPO at 21 days old (repair normal). Proliferation was measured by the nuclear incorporation of 5-chloro-2'-deoxyuridine (CldU) within epithelium at the target site (terminal bronchiole). The repair pattern between the two age groups was histologically defined. There was no difference in the CdlU labeling index during the week of repair between the two age groups, even though the bronchiolar epithelium did not return to normal in the animals treated at 7 days old. In summary, proliferation (through S-phase) is not inhibited during repair in neonatal rabbits treated with IPO at 7 days old compared to animals treated at 21 days old, and we conclude that other factors may be responsible for the altered repair in the young neonates injured by a P450-mediated cytotoxicant

  8. Perfusion CT of the Brain and Liver and of Lung Tumors: Use of Monte Carlo Simulation for Patient Dose Estimation for Examinations With a Cone-Beam 320-MDCT Scanner.

    Science.gov (United States)

    Cros, Maria; Geleijns, Jacob; Joemai, Raoul M S; Salvadó, Marçal

    2016-01-01

    The purpose of this study was to estimate the patient dose from perfusion CT examinations of the brain, lung tumors, and the liver on a cone-beam 320-MDCT scanner using a Monte Carlo simulation and the recommendations of the International Commission on Radiological Protection (ICRP). A Monte Carlo simulation based on the Electron Gamma Shower Version 4 package code was used to calculate organ doses and the effective dose in the reference computational phantoms for an adult man and adult woman as published by the ICRP. Three perfusion CT acquisition protocols--brain, lung tumor, and liver perfusion--were evaluated. Additionally, dose assessments were performed for the skin and for the eye lens. Conversion factors were obtained to estimate effective doses and organ doses from the volume CT dose index and dose-length product. The sex-averaged effective doses were approximately 4 mSv for perfusion CT of the brain and were between 23 and 26 mSv for the perfusion CT body protocols. The eye lens dose from the brain perfusion CT examination was approximately 153 mGy. The sex-averaged peak entrance skin dose (ESD) was 255 mGy for the brain perfusion CT studies, 157 mGy for the lung tumor perfusion CT studies, and 172 mGy for the liver perfusion CT studies. The perfusion CT protocols for imaging the brain, lung tumors, and the liver performed on a 320-MDCT scanner yielded patient doses that are safely below the threshold doses for deterministic effects. The eye lens dose, peak ESD, and effective doses can be estimated for other clinical perfusion CT examinations from the conversion factors that were derived in this study.

  9. MRI methods for pulmonary ventilation and perfusion imaging; Methoden der MRT zur Ventilations- und Perfusionsbildgebung der Lunge

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin, Basel (Switzerland); Bauman, G. [Universitaetsspital Basel, Klinik fuer Radiologie und Nuklearmedizin - Radiologische Physik, Basel (Switzerland)

    2016-02-15

    Separate assessment of respiratory mechanics, gas exchange and pulmonary circulation is essential for the diagnosis and therapy of pulmonary diseases. Due to the global character of the information obtained clinical lung function tests are often not sufficiently specific in the differential diagnosis or have a limited sensitivity in the detection of early pathological changes. The standard procedures of pulmonary imaging are computed tomography (CT) for depiction of the morphology as well as perfusion/ventilation scintigraphy and single photon emission computed tomography (SPECT) for functional assessment. Magnetic resonance imaging (MRI) with hyperpolarized gases, O{sub 2}-enhanced MRI, MRI with fluorinated gases and Fourier decomposition MRI (FD-MRI) are available for assessment of pulmonary ventilation. For assessment of pulmonary perfusion dynamic contrast-enhanced MRI (DCE-MRI), arterial spin labeling (ASL) and FD-MRI can be used. Imaging provides a more precise insight into the pathophysiology of pulmonary function on a regional level. The advantages of MRI are a lack of ionizing radiation, which allows a protective acquisition of dynamic data as well as the high number of available contrasts and therefore accessible lung function parameters. Sufficient clinical data exist only for certain applications of DCE-MRI. For the other techniques, only feasibility studies and case series of different sizes are available. The clinical applicability of hyperpolarized gases is limited for technical reasons. The clinical application of the techniques described, except for DCE-MRI, should be restricted to scientific studies. (orig.) [German] Die separate Beurteilung von Atemmechanik, Gasaustauschprozessen und Lungenzirkulation ist wesentlich fuer die Diagnose und Therapie von Lungenerkrankungen. Klinische Lungenfunktionstests sind aufgrund ihrer zumeist nur globalen Aussage oft nicht hinreichend spezifisch in der Differenzialdiagnostik oder eingeschraenkt sensitiv bei der

  10. Preparation of 99m Tc-Macroaggregated albumin for lung perfusion studies

    International Nuclear Information System (INIS)

    Alfonso Marin, Yumisley; Zayas Crespo, Francisco I.; Mesa Duennas Niurka; Hernandez Gonzalez, Ignacio; Leon Perez, Mariela; Rivero Santamaria, Alejandro

    2009-01-01

    The present paper shows the design, optimization, quality control for testing radiochemical purity, biological quality and realtime stability studies of a preparation of macroaggregated albumin from the controlled denaturation of HSA. An experimental design with a 2 3 factorial plan was carried out in order to determine the ideal conditions for the preparation. The results showed that variations of albumin concentrations within the range of 515 mg/mL were irrelevant, however, the final pH of the mixture and the stirring speed were significant variables, as well as their interaction. Formulations with particles of diameter between 11 and 80 μ were obtained with the conditions selected in the experimental design which met the internationally established criteria for radiochemical purity, sterility and apyrogenicity. The biodistribution in experimental animals showed good quality lung images. The produced lots maintained physical, radiochemical, biological and microbiological stability during 90 days of storage at 4 o C. Key words: albumins, blood serum, emboli, labelling, lungs, quality control, radiopharmaceuticals, thrombosis, technetium 99. (author)

  11. Reverse ventilation--perfusion mismatch

    International Nuclear Information System (INIS)

    Palmaz, J.C.; Barnett, C.A.; Reich, S.B.; Krumpe, P.E.; Farrer, P.A.

    1984-01-01

    Patients having lobar airway obstruction or consolidation usually have decreases of both ventilation and perfusion on lung scans. We report three patients in whom hypoxic vasoconstriction was apparently incomplete, resulting in a ''reversed'' ventilation-perfusion mismatch. Perfusion of the hypoxic lobe on the radionuclide scan was associated with metabolic alkalosis, pulmonary venous and pulmonary arterial hypertension in these patients

  12. Correlation between [{sup 18}F]FDG PET/CT and volume perfusion CT in primary tumours and mediastinal lymph nodes of non-small-cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sauter, Alexander W.; Spira, Daniel; Schulze, Maximilian; Pfannenberg, Christina; Claussen, Claus D.; Horger, Marius S. [Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Hetzel, Juergen [Eberhard Karls University, Department of Oncology, Hematology, Immunology, Rheumatology and Pulmonology, Tuebingen (Germany); Reimold, Matthias [Eberhard Karls University, Nuclear Medicine, Department of Radiology, Tuebingen (Germany); Klotz, Ernst [Siemens Healthcare, Computed Tomography, Forchheim (Germany)

    2013-05-15

    The aim of this study was to investigate correlations between glucose metabolism as determined by [{sup 18}F]FDG PET/CT and tumour perfusion as quantified by volume perfusion CT in primary tumours and mediastinal lymph nodes (MLN) of patients with non-small-cell lung cancer (NSCLC). Enrolled in the study were 17 patients with NSCLC. [{sup 18}F]FDG uptake was quantified in terms of SUV{sub max} and SUV{sub avg}. Blood flow (BF), blood volume (BV) and flow extraction product (K{sup trans}) were determined as perfusion parameters. The correlations between the perfusion parameters and [{sup 18}F]FDG uptake values were subsequently evaluated. For the primary tumours, no correlations were found between perfusion parameters and [{sup 18}F]FDG uptake. In MLN, there were negative correlations between BF and SUV{sub avg} (r = -0.383), BV and SUV{sub avg} (r = -0.406), and BV and SUV{sub max} (r = -0.377), but not between BF and SUV{sub max}, K{sup trans} and SUV{sub avg}, or K{sup trans} and SUV{sub max}. Additionally, in MLN with SUV{sub max} >2.5 there were negative correlations between BF and SUV{sub avg} (r = -0.510), BV and SUV{sub avg} (r = -0.390), BF and SUV{sub max} (r = -0.536), as well as BV and SUV{sub max} (r = -0.346). Perfusion and glucose metabolism seemed to be uncoupled in large primary tumours, but an inverse correlation was observed in MLN. This information may help improve therapy planning and response evaluation. (orig.)

  13. An experimental study on the radiation-induced injury of the rabbit lung: Correlation of soft-tissue radiograph and high- resolution CT findings with pathologic findings

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Nam, Kyung Jin; Park, Byeoung Ho; Jeong, Jin Sook; Lee, Hyung Sik

    1994-01-01

    To describe soft-tissue radiographic and high-resolution CT findings of radiation-induced lung injury of rabbit over time and to correlate them with pathologic findings. 15 rabbits were irradiated in the right lung with one fracture of 2000 cGy. After 4, 6, 12, 20, 24 weeks 3 rabbits in each group were sacrificed and soft-tissue radiographs and high-resolution CT of their lung tissue were obtained. Radiological findings were correlated with pathologic findings. On soft-tissue radiogram, radiation pneumonitis shown as consolidation with air- bronchogram occurred in 3 cases after 6 weeks , and in 1 case after 12 weeks of irradiation. In addition, pneumonic consolidation with adjacent pleural contraction was seen in 2 cases after 12 weeks of irradiation. Fibrotic changes indicated by decreased volume occurred after 20 weeks and combined bronchiectatic change and bronchial wall thickening appeared after 20 weeks(N=1), and 24 weeks(N=3). HRCT findings of radiation pneumonitis were homogeneous, increased attention after 4 weeks(N=3), 6 and 12 weeks(each N=1), patchy consolidation after 6 and 12 weeks(each N=2), discrete consolidation after 12, 20 and 24 weeks(each N=1) and solid consolidation after 20 and 24 weeks(each N=2). Pathologically radiation pneumonitis and pulmonary congestion were seen after 4 and 6 weeks. After 6 weeks, collagen and reticulin fibers were detected along alveolar wall. Mixed radiation pneumonitis and fibrosis were detected after 12 weeks. 20 weeks after irradiation, fibrosis was well defined in interstitium and in 24 weeks, decreased number of alveoli and thickening of bronchial wall were defined. Radiation pneumonitis was provoked 4 weeks after irradiation on rabbit lung and progressed into radiation fibrosis 20 weeks after irradiation on soft-tissue radiographs and high-resolution CT. High-resolution CT is more precise in detecting early radiation pneumonitis and detailed pathologic findings

  14. Feasibility of perfusion CT technique integrated into conventional {sup 18}FDG/PET-CT studies in lung cancer patients: clinical staging and functional information in a single study

    Energy Technology Data Exchange (ETDEWEB)

    Ippolito, Davide; Capraro, Cristina; Sironi, Sandro [University of Milano-Bicocca, School of Medicine, Milan (Italy); University of Milano-Bicocca, Department of Diagnostic Radiology, H.S. Gerardo Monza, Via Pergolesi 11, Monza, Milan (Italy); Guerra, Luca [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Nuclear Medicine and PET Unit - Molecular Bioimaging Centre, Monza (Italy); De Ponti, Elena [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Medical Physics, Monza (Italy); Messa, Cristina [University of Milano-Bicocca, School of Medicine, Milan (Italy); San Gerardo Hospital, Department of Nuclear Medicine and PET Unit - Molecular Bioimaging Centre, Monza (Italy); Tecnomed Foundation, University of Milano-Bicocca, Institute for Bioimaging and Molecular Physiology, National Research Council, Milan (Italy)

    2013-02-15

    To assess the additional functional vascular information and the relationship between perfusion measurements and glucose metabolism (SUVmax) obtained by including a perfusion CT study in a whole-body contrast-enhanced PET/CT protocol in primary lung cancer lesions. Enrolled in this prospective study were 34 consecutive patients with a biopsy-proven diagnosis of lung cancer who were referred for contrast-enhanced PET/CT staging. This prospective study was approved by our institutional review board, and informed consent was obtained from all patients. Perfusion CT was performed with the following parameters: 80 kV, 200 mAs, 30 scans during intravenous injection of 50 ml contrast agent, flow rate 5 ml/s. Another bolus of contrast medium (3.5 ml/s, 80 ml, 60-s delay) was administered to ensure a full diagnostic contrast-enhanced CT scan for clinical staging. The perfusion CT data were used to calculate a range of tumour vascularity parameters (blood flow, blood volume and mean transit time), and tumour FDG uptake (SUVmax) was used as a metabolic indicator. Quantitative and functional parameters were compared and in relation to location, histology and tumour size. The nonparametric Kruskal-Wallis rank sum test was used for statistical analysis. A cut-off value of 3 cm was used according to the TNM classification to discriminate between T1 and T2 tumours (i.e. T1b vs. T2a). There were significant perfusion differences (lower blood volumes and higher mean transit time) between tumours with diameter >30 mm and tumours with diameter <30 mm (p < 0.05; blood volume 5.6 vs. 7.1 ml/100 g, mean transit time 8.6 vs. 3.9 s, respectively). Also there was a trend for blood flow to be lower in larger lesions (p < 0.053; blood flow 153.1 vs. 98.3 ml/100 g tissue/min). Significant inverse correlations (linear regression) were found between blood volume and SUVmax in tumours with diameter >30 mm in diameter. Perfusion CT combined with PET/CT is feasible technique that may provide

  15. Induction of rabbit lung cytochrome P450 prostaglandin in omega-hyroxylase during pregnancy: evidence for regulation at the genetic level

    International Nuclear Information System (INIS)

    Master, B.S.S.; Muerhoff, A.S.; Jackson, V.; Williams, D.E.; Waterman, M.R.; Johnson, E.F.

    1986-01-01

    The induction of a cytochrome P450 prostaglandin omega-hydroxylase (P450/sub PG omega/) isolated from pregnant rabbit lung has been shown by Western blots to be concomitant with an increase in the amount of P450 protein. Peaks in enzyme activity and P450/sub PG omega/ protein occur between the 20th and 28th days of gestation with increases of more than 100-fold compared to nonpregnant rabbits. To elucidate the mechanisms controlling induction, total cellular RNA was extracted from rabbit lungs at various days of gestation, translated in vitro using 35 S-met, and the newly synthesized P450/sub PG omega/ immunoprecipitated from the lysate. Utilizing an immunopurified goat IgG to P450/sub PG omega/, immunopellets of in vitro translation reactions charged with RNA from lungs at 6,11,19,22,25, or 28-days gestation were isolated. A single band corresponding to P450/sub PG omega/ was seen in autoradiographs of SDS-PAGE gels containing these immunopellets, but no band was visible in lanes containing immunopellets from reactions charged with RNA from nonpregnant or 1-day post-partum animals. The gestational time-dependent increase in in vitro-translated P450/sub PG omega/ suggests that control of its induction during pregnancy is at the transcriptional level. A monoclonal antibody to the P450/sub PG omega/ has been produced for the isolation of the P450/sub PG omega/ mRNA for cDNA production

  16. Lung perfusion scanning studies on pulmonary radiolesions after /sup 60/Co teletherapy of operated cancer of the breast and on polycythaemia vera following radiophosphorus therapy

    Energy Technology Data Exchange (ETDEWEB)

    Herzog, M

    1973-01-01

    When X-ray and scintigraphic control examinations were carried out on 75 patients with cancer of the breast, the X-ray examinations showed pulmonary radiolesions in 37.3% (28 patients) at an average of 12 weeks after radiotherapy with tele /sup 60/Co. The scintigraphic examination, on the other hand, showed a reduced activity concentration - a sign of disturbed blood flow through the lungs - in only 13.0% (9 patients). A reactive increase in blood flow in the form of a higher particle concentration in the irradiated lobe of the lung immediately after irradiation was scintigraphically detected in 21.3% (16 patients). In 15 patients with polycythaemia vera who had been treated with /sup 32/P, the lung perfusion scan detected 4 cases of stopped blood supply without correlative X-ray findings or episodes of embolism in clinical anamnesis.

  17. Lung scintigraphy

    International Nuclear Information System (INIS)

    Dalenz, Roberto.

    1994-01-01

    A review of lung scintigraphy, perfusion scintigraphy with SPECT, lung ventilation SPECT, blood pool SPECT. The procedure of lung perfusion studies, radiopharmaceutical, administration and clinical applications, imaging processing .Results encountered and evaluation criteria after Biello and Pioped. Recommendations and general considerations have been studied about relation of this radiopharmaceutical with other pathologies

  18. Nuclear magnetic resonance of perfused tissue

    International Nuclear Information System (INIS)

    Harpen, M.D.; Allison, R.C.

    1986-01-01

    The effect of perfusion on the NMR signal observed in NMR imaging is studied in a phantom and in two isolated perfused canine lungs. It is observed that perfusion in tissue has little effect on longitudinal relaxation times. Transverse relaxation rates are observed to correlate linearly with rates of perfusion, in accordance with a model presented. (author)

  19. Reevaluation of lung perfusion scintigrams with 99mTc-macroaggregated albumin (Tc-MAA) as a tool of diagnostic procedures of chronic pulmonary emphysema

    International Nuclear Information System (INIS)

    Kitahara, Yoshinari; Maruyama, Masao; Takamoto, Masahiro; Tanaka, Yasushi; Harada, Susumu; Harada, Yasuko; Ishibashi, Tsuneo; Shinoda, Atsushi

    1991-01-01

    We performed scintiscanning with Tc-MAA lung perfusion in thirty cases of chronic pulmonary emphysema (CPE) and thirty cases of bronchial asthma. In the former group, all of the cases showed the definite emphysematous changes on computed tomography (CT). It seemed that the whole impression to scintigram could diagnose CPE almost correctly. As the most important abnormality in scintigrams of CPE was their filling defects, we examined the characteristics of the defect-lesions. The results were as follows: firstly, the main lesions extended to the lobar to half-lobar size; secondly, defects were multiple in general; and thirdly, the distribution of defects was diffuse. Whereas the lesion in the scintigram is nonspecific for diagnosis of CPE in contrast to CT, we conclude that perfusion scintigram is valuable to evaluate the severity of CPE. (author)

  20. Radio frequency ablation in the rabbit lung using wet electrodes: comparison of monopolar and dual bipolar electrode mode

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Park, Sang Hee; Han, Young Min; Chung, Gyung Ho; Kwak, Hyo Sung; Jeon, Soo Bin; Lee, Yong Chul

    2006-01-01

    To compare the effect of radio frequency ablation (RFA) on the dimensions of radio frequency coagulation necrosis in a rabbit lung using a wet electrode in monopolar mode with that in dual electrode bipolar mode at different infusion rates (15 mm/hr versus 30 ml/hr) and saline concentrations (0.9% normal versus 5.8% hypertonic saline. Fifty ablation zones (one ablation zone in each rabbit) were produced in 50 rabbit using one or two 16-guage wet electrodes with a 1- cm active tip. The RFA system used in the monopolar and dual electrode wet bipolar RFA consisted of a 375-kHz generator (Elektrotom HiTT 106, Berchtold, Medizinelektronik, Germany). The power used was 30 watts and the exposure time was 5 minutes. The rabbits were assigned to one of five groups. Group A (n = 10) was infused with 0.9% NaCl used at a rate of 30 ml/hr in a monopolar mode. Groups B (n=10) and C (n=10) were infused with 0.9% NaCl at a rate of 15 and 30ml/hr, respectively in dual electrode bipolar mode; groups D (n=10) and E (n=10) were infused with 5.8% NaCl at a rate of 15 and 30 ml/hr, respectively in a dual electrode bipolar mode. The dimensions of the ablation zones in the gross specimens from the groups were compared using one-way analysis of variance by means of the Scheffe test (post-hoc testing). The mean largest diameter of the ablation zones was larger in dual electrode bipolar mode (30.9 ± 4.4 mm) than in monopolar mode (22.5 ± 3.5 mm). The mean smallest diameter of the ablation zones was larger in dual electrode bipolar mode (22.3 ± 2.5 mm) than in monopolar mode (19.5 ± 3.5 mm). There were significant differences in the largest and smallest dimension between the monopolar (group A ) ana dual electrode wet bipolar mode (groups B-E). In dual electrode bipolar mode, the mean largest diameter of the ablation zones was larger at an infusion rate of 15 ml/hr (34.2 ± 4.0 mm) than at 30 ml/hr (27.6 ± 0.0 mm), and the mean smallest diameter of the ablation zones was larger at an

  1. Percutaneous radiofrequency thermal ablation of lung VX2 tumors in a rabbit model: evaluation with helical CT findings for the complete and partal ablation

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Gong Yong; Han, Young Min; Lim, Yeong Su; Jang, Kyu Yun; Lee, Sang Yong; Chung, Gyung Ho [School of Medicine, Chonbuk National Univ., Chonju (Korea, Republic of)

    2004-05-01

    To evaluate the radiologic findings for complete and partial ablation after percutaneous CT-guided transthoracic radiofrequency ablation (RFA) of lung VX2 tumor implanted in rabbits. Thirteen rabbits with successfully implanted lung VX2 were used. Three rabbits as controls did not receive RFA while the other ten rabbits underwent RFA; 5 complete and 5 partial. RFA was performed using an internally cooled, 17-gauge electrode (Radionics, Burlington, MA) with a 1-cm active tip under CT guidance. Postprocedural CT was performed within 3 days, and we analyzed the ablated size, enhancement pattern, shape, margin, and complications of the complete and partial ablation groups. Rabbits were sacrificed after postprocedural CT with an overdose of ketamine, and pathologic findings of the ablated groups were compared with those of the control group. The size of the ablated lesions and the enhancement pattern differed between the completely and partially ablated groups on chest CT. The size of the ablated lesions was increased by 47.1% in the completely ablated group and by 2.1% in the partially ablated group. In the completely ablated group, VX2 tumor showed absolutely no enhancement, whereas only ablated pulmonary parenchyma outside VX2 showed mild enhancement on enhanced CT. In the partial ablated group, a part of VX2 became strongly enhanced on enhanced CT. On microscopic examination, the completely ablated group demonstrated that a viable tumor cell was not visible. In the partially ablated group, however, a viable tumor cell within the surrounding fibrous capsule on the peripheral area of the VX2 was observed. The important CT findings for evaluation of complete and partial RFA are the ablated size and enhancement pattern of the ablated lesion.

  2. Evaluation of mosaic pattern areas in HRCT with Min-IP reconstructions in patients with pulmonary hypertension: Could this evaluation replace lung perfusion scintigraphy?

    International Nuclear Information System (INIS)

    Rossi, A.; Attinà, D.; Borgonovi, A.; Buia, F.; De Luca, F.; Guidalotti, P.L.; Fughelli, P.; Galiè, N.; Zompatori, M.

    2012-01-01

    Purpose: The aim of this study is to evaluate a possible correlation between areas of lung attenuation, found in minimum intensity projection (Min-IP) reconstruction images performed with high resolution computed tomography without contrast medium (HRCT), and areas of lung perfusion alteration, found in lung perfusion scintigraphy (LPS). Materials and methods: Two independent radiologists, unaware of LPS results, evaluated retrospectively a group of 113 patients affected by pulmonary hypertension (HP) of different aetiology. These have been examined in a period of two years in our centre both by spiral computed tomography (CT) with and without contrast-medium and by LPS. The final diagnosis was determined on clinical data, right heart catheterisation and contrast enhanced CT in angiographic phase (CTPA). We reconstructed the Min-IP images of lung parenchyma in all the cases both in HRCT without contrast-medium, and in contrast enhanced CT in angiographic phase (CTPA) in axial, sagittal and coronal planes. The obtained images were qualitatively graded into three categories of pulmonary attenuation: homogeneous, inhomogeneous with non-segmental patchy defects, inhomogeneous with segmental defects. The same criteria of classification were used also for LPS images. In the group of patients with chronic thromboembolic pulmonary hypertension (CTEPH) we also compared the number of areas of lung attenuation found in Min-IP images in HRCT without contrast-medium, and their exact localization, with not perfused areas in LPS. Gold standard for the diagnosis of pulmonary embolism was spiral contrast enhanced CT in angiographic phase (CTPA). Results: In all cases we found exact correspondence between the Min-IP images in HRCT with and without contras agent. The attenuation pattern seen on Min-IP images was concordant with those of LPS in 96 out of 113 patients (85%). In the remaining 17 cases (15%) it was discordant: in 12 cases inhomogeneous in Min-IP images (7 with non

  3. Diagnostic value of static and dynamic scintigraphy in diagnosis of acute respiratory distress syndrome in the course of sepsis. Part 1. Lung perfusion scintigraphy

    International Nuclear Information System (INIS)

    Jurgilewicz, D.; Rogowski, F.; Malinowska, L.

    1997-01-01

    One of the most important complication of sepsis is acute respiratory distress syndrome (ARDS). Diagnosis of the illness is mainly based on chest radiography and gasometric parameters of the blood. The aim of the study was to estimate the diagnostic usefulness of lung perfusion scintigraphy in early detection of blood flow and gas-exchange abnormalities in patients with ARDS in the course of sepsis. Scintigraphic studies of 12 patients in critical condition were performed, using Hungarian planar gamma camera type MB9200 and human albumin microspheres labelled with 99m Tc. Perfusion scans of patients with ARDS demonstrated blurring outlines and abundant diffuse foci of lack of radioactivity in both lungs and quantitative analysis indicated relative increase of Tc99m-MSA accumulation in upper zones of both lungs. Scans of suffering from sepsis were similar to control one. The course of the studies showed that scintigraphic methods could be safely use in patients with sepsis and ARDS and may be helpful in the early diagnosis of ARDS in the septic patients. (author)

  4. Role of Nrf2/ARE pathway in protective effect of electroacupuncture against endotoxic shock-induced acute lung injury in rabbits.

    Directory of Open Access Journals (Sweden)

    Jian-bo Yu

    Full Text Available NF-E2 related factor 2 (Nrf2 is a major transcription factor and acts as a key regulator of antioxidant genes to exogenous stimulations. The aim of current study was to determine whether Nrf2/ARE pathway is involved in the protective effect of electroacupuncture on the injured lung in a rabbit model of endotoxic shock. A dose of lipopolysaccharide (LPS 5 mg/kg was administered intravenously to replicate the model of acute lung injury induced by endotoxic shock. Electroacupuncture pretreatment was handled bilaterally at Zusanli and Feishu acupoints for five consecutive days while sham electroacupuncture punctured at non-acupoints. Fourty anesthetized New England male rabbits were randomized into normal control group (group C, LPS group (group L, electroacupuncture + LPS group (group EL and sham electroacupuncture + LPS (group SEL. At 6 h after LPS administration, the animals were sacrificed and the blood samples were collected for biochemical measurements. The lungs were removed for calculation of wet-to-dry weight ratios (W/D, histopathologic examination, determination of heme oxygenase (HO-1 protein and mRNA, Nrf2 total and nucleoprotein, as well as Nrf2 mRNA expression, and evaluation of the intracellular distribution of Nrf2 nucleoprotein. LPS caused extensive morphologic lung damage, which was lessened by electroacupuncture treatment. Besides, lung W/D ratios were significantly decreased, the level of malondialdehyde was inhibited, plasma levels of TNF-α and interleukin-6 were decreased, while the activities of superoxide dismutase, glutathione peroxidase and catalase were enhanced in the electroacupucnture treated animals. In addition, electroacupuncture stimulation distinctly increased the expressions of HO-1 and Nrf2 protein including Nrf2 total protein and nucleoprotein as well as mRNA in lung tissue, while these effects were blunted in the sham electroacupuncture group. We concluded that electroacupuncture treatment at ST36 and BL13

  5. Role of Nrf2/ARE pathway in protective effect of electroacupuncture against endotoxic shock-induced acute lung injury in rabbits.

    Science.gov (United States)

    Yu, Jian-bo; Shi, Jia; Gong, Li-rong; Dong, Shu-an; Xu, Yan; Zhang, Yuan; Cao, Xin-shun; Wu, Li-li

    2014-01-01

    NF-E2 related factor 2 (Nrf2) is a major transcription factor and acts as a key regulator of antioxidant genes to exogenous stimulations. The aim of current study was to determine whether Nrf2/ARE pathway is involved in the protective effect of electroacupuncture on the injured lung in a rabbit model of endotoxic shock. A dose of lipopolysaccharide (LPS) 5 mg/kg was administered intravenously to replicate the model of acute lung injury induced by endotoxic shock. Electroacupuncture pretreatment was handled bilaterally at Zusanli and Feishu acupoints for five consecutive days while sham electroacupuncture punctured at non-acupoints. Fourty anesthetized New England male rabbits were randomized into normal control group (group C), LPS group (group L), electroacupuncture + LPS group (group EL) and sham electroacupuncture + LPS (group SEL). At 6 h after LPS administration, the animals were sacrificed and the blood samples were collected for biochemical measurements. The lungs were removed for calculation of wet-to-dry weight ratios (W/D), histopathologic examination, determination of heme oxygenase (HO)-1 protein and mRNA, Nrf2 total and nucleoprotein, as well as Nrf2 mRNA expression, and evaluation of the intracellular distribution of Nrf2 nucleoprotein. LPS caused extensive morphologic lung damage, which was lessened by electroacupuncture treatment. Besides, lung W/D ratios were significantly decreased, the level of malondialdehyde was inhibited, plasma levels of TNF-α and interleukin-6 were decreased, while the activities of superoxide dismutase, glutathione peroxidase and catalase were enhanced in the electroacupucnture treated animals. In addition, electroacupuncture stimulation distinctly increased the expressions of HO-1 and Nrf2 protein including Nrf2 total protein and nucleoprotein as well as mRNA in lung tissue, while these effects were blunted in the sham electroacupuncture group. We concluded that electroacupuncture treatment at ST36 and BL13 effectively

  6. Important casual association of carotid body and glossopharyngeal nerve and lung following experimental subarachnoid hemorrhage in rabbits. First report.

    Science.gov (United States)

    Yolas, Coskun; Kanat, Ayhan; Aydin, Mehmet Dumlu; Turkmenoglu, Osman Nuri; Gundogdu, Cemal

    2014-01-15

    The glossopharyngeal nerves (GPNs) and carotid bodies (CBs) have an important role in the continuation of the cerebral autoregulation and cardiorespiratory functions. The relationship between degenerative injury of CB and the GPN in subarachnoid hemorrhage (SAH) was studied. Twenty rabbits were included in this study. Five of them (n=5) were used as control group. The remaining animals (n=15) were exposed to experimental SAH. In the six animals of the SAH group, severe signs of illness were observed, and these six animals were killed in the first week after SAH. Others animals (n=9) were followed for 20 days and then sacrificed. GPNs and CBs were examined and, the live and degenerated GPN axon number, and of CB neuron numbers were stereologically estimated. The mean number of live neurons in CBs was 4206.67±148.35 and live axons of GPNs were 1211.66±14.29 in the animals of the control group. The number of degenerated neurons of CBs was 2065±110.27 and the number of degenerated axons of GPNs was 530.83±43.48 in early killed animals with SAH. The number of degenerated neurons of CBs and the number of degenerated axons of GPNs were found as 1013.89±4184 and 2270.5±134.38 in the living animals with SAH, respectively. High number of degenerated axons of GPN and neurons of CBs of the early killed animals suggest that the mortality in early SAH might be due to GPNs injury secondary to compression of their axons or supplying vessels by the probably herniated brainstem, and secondary denervation injury of CBs, and lung. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  7. A hybrid breath hold and continued respiration-triggered technique for time-resolved 3D MRI perfusion studies in lung cancer

    International Nuclear Information System (INIS)

    Hintze, C.; Stemmer, A.; Bock, M.

    2010-01-01

    Assessment of lung cancer perfusion is impaired by respiratory motion. Imaging times for contrast agent wash-out studies often exceed breath hold capabilities, and respiration triggering reduces temporal resolution. Temporally resolved volume acquisition of entire tumors is required to assess heterogeneity. Therefore, we developed and evaluated an MR measurement technique that exceeds a single breath hold, and provides a variable temporal resolution during acquisition while suspending breath-dependent motion. 20 patients with suspected lung cancer were subjected to perfusion studies using a spoiled 3D gradient echo sequence after bolus injection of 0.07 mmol/kg body weight of Gd-DTPA. 10 acquisitions in expiratory breath hold were followed by 50 navigator-triggered acquisitions under free breathing. Post-processing allowed for co-registration of the 3D data sets. An ROI-based visualization of the signal-time curves was performed. In all cases motion-suspended, time-resolved volume data sets (40 x 33 x 10 cm 3 , voxel size: 2.1 x 2.1 x 5.0 mm 3 ) were generated with a variable, initially high temporal resolution (2.25 sec) that was synchronized with the breath pattern and covered up to 8(1)/(2) min. In 7 / 20 cases a remaining offset could be reduced by rigid co-registration. The tumors showed fast wash-in, followed by rapid signal decay (8 / 20) or a plateau. The feasibility of a perfusion study with hybrid breath hold and navigator-triggered time-resolved 3D MRI which combines high initial temporal resolution during breath hold with a long wash-out period under free breathing was demonstrated. (orig.)

  8. Lung

    International Nuclear Information System (INIS)

    DeNardo, G.L.; Blankenship, W.J.; Burdine, J.A. Jr.; DeNardo, S.J.

    1975-01-01

    At present no simple statement can be made relative to the role of radionuclidic lung studies in the pediatric population. It is safe to assume that they will be used with increasing frequency for research and clinical applications because of their sensitivity and ready applicability to the pediatric patient. Methods comparable to those used in adults can be used in children older than 4 years. In younger children, however, a single injection of 133 Xe in solution provides an index of both regional perfusion and ventilation which is easier to accomplish. This method is particularly valuable in infants and neonates because it is rapid, requires no patient cooperation, results in a very low radiation dose, and can be repeated in serial studies. Radionuclidic studies of ventilation and perfusion can be performed in almost all children if the pediatrician and the nuclear medicine specialist have motivation and ingenuity. S []ontaneous pulmonary vascular occlusive disease which occurs in infants and pulmonary emboli in children are easily detected using radionuclides. The pathophysiologic defects of pulmonary agenesis, bronchopulmonary sequestration, and foreign body aspiration may be demonstrated by these techniques. These techniques also appear to be useful in following patients with bronchial asthma, cystic fibrosis, congenital emphysema, and postinfection pulmonary abnormalities. (auth)

  9. Pulmonary clearance of 99mTc-DTPA and 99mTc-albumin in rabbits with surfactant dysfunction and lung injury

    International Nuclear Information System (INIS)

    Nilsson, K.; Wollmer, P.

    1992-01-01

    We measured the pulmonary clearance of inhaled 99m Tc-DTPA and 99m Tc-albumin in rabbits with surfacant dysfunction induced by dioctyl sodium sulphosuccinate and in rabbits with lung injury induced by oleic acid. After inhalation of 99m Tc-albumin in ten animals, clearance of the tracer from the lungs was monitored for 90 min. The first 30 min was a control period. Dioctyl sodium sulphosuccinate was then administered in aerosol and after another 30 min oleic acid was injected intravenously. Ten other rabbits were given 99m Tc-DTPA, and clearance was externally recorded for 60 min. Five animals inhaled detergent aerosol and five animals were given oleic acid intravenously after 30 min. Airway pressures, tidal volume, and arterial blood gases were measured before and after each intervention. The half-life of 99m Tc-albumin in the lung was 442 ± 123 min during the control period, 363 ± 52 min after detergent administration, and 134 ± 18 min after oleic acid administration. The half-life of 99m Tc-DTPA was 94 ± 16 min before and 10 ± 0.6 min after detergent administration and 75 ± 12 min before and 18 ± 1.8 min after oleic acid administration. Gas exchange was not affected by administration of dioctyl sodium sulphosuccinate but markedly impaired after injection of oleic acid. Compliance of the respiratory system remained unaffected by detergent but decreased after injection of oleic acid. The results indicate that the rate limiting factors for the alveolo-capillary transfer of 99m Tc-albumin and 99m Tc-DTPA are different. Surfactant dysfunction affects the transfer of 99m Tc-DTPA but not 99m Tc-albumin. (author)

  10. Modelo experimental de perfusão pulmonar ex vivo em ratos: avaliação de desempenho de pulmões submetidos à administração de prostaciclina inalada versus parenteral An experimental rat model of ex vivo lung perfusion for the assessment of lungs after prostacyclin administration: inhaled versus parenteral routes

    Directory of Open Access Journals (Sweden)

    Paulo Francisco Guerreiro Cardoso

    2011-10-01

    Full Text Available OBJETIVO: Apresentar um modelo experimental de administração de prostaglandina I2 (PGI2 por via inalatória vs. parenteral e avaliar o desempenho funcional dos pulmões em um sistema de perfusão pulmonar ex vivo. MÉTODOS: Quarenta ratos Wistar foram anestesiados, ventilados, submetidos a laparotomia com ressecção do esterno e anticoagulados. O tronco da artéria pulmonar foi canulado. Todos os animais foram submetidos a ventilação mecânica. Os animais foram randomizados em quatro grupos (10 ratos/grupo: salina nebulizada (SN; salina parenteral (SP; PGI2 nebulizada (PGI2N; e PGI2 parenteral (PGI2P. A dose de PGI2 nos grupos PGI2N e PGI2P foi de 20 e 10 µg/kg, respectivamente. Os blocos cardiopulmonares foram submetidos in situ a perfusão anterógrada com solução de baixo potássio e dextrana a 4ºC via artéria pulmonar, extraídos em bloco e armazenados a 4ºC por 6 h. Os blocos foram ventilados e perfundidos em um sistema ex vivo por 50 min, sendo obtidas medidas de mecânica ventilatória, hemodinâmica e trocas gasosas. RESULTADOS: Houve redução da pressão arterial pulmonar média após a nebulização em todos os grupos (p OBJECTIVE:To present a model of prostaglandin I2 (PGI2 administration (inhaled vs. parenteral and to assess the functional performance of the lungs in an ex vivo lung perfusion system. METHODS: Forty Wistar rats were anesthetized and placed on mechanical ventilation followed by median sterno-laparotomy and anticoagulation. The main pulmonary artery was cannulated. All animals were maintained on mechanical ventilation and were randomized into four groups (10 rats/group: inhaled saline (IS; parenteral saline (PS; inhaled PGI2 (IPGI2; and parenteral PGI2 (PPGI2. The dose of PGI2 used in the IPGI2 and PPGI2 groups was 20 and 10 µg/kg, respectively. The heart-lung blocks were submitted to antegrade perfusion with a low potassium and dextran solution via the pulmonary artery, followed by en bloc extraction and

  11. Comparisons of different mean airway pressure settings during high-frequency oscillation in inflammatory response to oleic acid-induced lung injury in rabbits

    Directory of Open Access Journals (Sweden)

    Koichi Ono

    2009-03-01

    Full Text Available Koichi Ono1, Tomonobu Koizumi2, Rikimaru Nakagawa1, Sumiko Yoshikawa2, Tetsutarou Otagiri11Department of Anesthesiology and Resuscitation; 2First Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, JapanPurpose: The present study was designed to examine effects of different mean airway pressure (MAP settings during high-frequency oscillation (HFO on oxygenation and inflammatory responses to acute lung injury (ALI in rabbits.Methods: Anesthetized rabbits were mechanically ventilated with a conventional mechanical ventilation (CMV mode (tidal volume 6 ml/kg, inspired oxygen fraction [FIo2] of 1.0, respiratory rate [RR] of 30/min, positive end-expiratory pressure [PEEP] of 5 cmH2O. ALI was induced by intravenous administration of oleic acid (0.08 ml/kg and the animals were randomly allocated to the following three experimental groups; animals (n = 6 ventilated using the same mode of CMV, or animals ventilated with standard MAP (MAP 10 cmH2O, n = 7, and high MAP (15 cmH2O, n = 6 settings of HFO (Hz 15. The MAP settings were calculated by the inflation limb of the pressure-volume curve during CMV.Results: HFO with a high MAP setting significantly improved the deteriorated oxygenation during oleic acid-induced ALI and reduced wet/dry ratios, neutrophil counts and interleukin-8 concentration in bronchoalveolar lavage fluid, compared to those parameters in CMV and standard MAP-HFO.Conclusions: These findings suggest that only high MAP setting during HFO could contribute to decreased lung inflammation as well as improved oxygenation during the development of ALI.Keywords: lung protective ventilation, open lung ventilation, IL-8, neutrophil

  12. Ventilation/perfusion SPECT in chronic obstructive pulmonary disease: an evaluation by reference to symptoms, spirometric lung function and emphysema, as assessed with HRCT

    Energy Technology Data Exchange (ETDEWEB)

    Joegi, Jonas; Bajc, Marika [Lund University, Skaane University Hospital, Department of Clinical Physiology, Institution of Clinical Sciences, Lund (Sweden); Ekberg, Marie [Lund University, Skaane University Hospital, Department of Respiratory Medicine and Allergology, Institution of Clinical Sciences, Lund (Sweden); Jonson, Bjoern [Lund University, Department of Clinical Physiology, Institution of Clinical Sciences, Lund (Sweden); Bozovic, Gracijela [Lund University, Skaane University Hospital, Department of Radiology, Institution of Clinical Sciences, Lund (Sweden)

    2011-07-15

    Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation which is not fully reversible. Despite the heterogeneity of COPD, its diagnosis and staging is currently based solely on forced expiratory volume in 1 s (FEV{sub 1}). FEV{sub 1} does not explain the underlying pathophysiology of airflow limitation. The relationship between FEV{sub 1}, symptoms and emphysema extent is weak. Better diagnostic tools are needed to define COPD. Tomographic lung scintigraphy [ventilation/perfusion single photon emission tomography (V/P SPECT)] visualizes regional V and P. In COPD, relations between V/P SPECT, spirometry, high-resolution computed tomography (HRCT) and symptoms have been insufficiently studied. The aim of this study was to investigate how lung function imaging and obstructive disease grading undertaken using V/P SPECT correlate with symptoms, spirometric lung function and degree of emphysema assessed with HRCT in patients with COPD. Thirty patients with stable COPD were evaluated with the Medical Research Council dyspnoea questionnaire (MRC) and the clinical COPD questionnaire (CCQ). Spirometry was performed. The extent of emphysema was assessed using HRCT. V/P SPECT was used to assess V/P patterns, total reduction in lung function and degree of obstructive disease. The total reduction in lung function and degree of obstructive disease, assessed with V/P SPECT, significantly correlated with emphysema extent (r = 0.66-0.69, p < 0.0001) and spirometric lung function (r = 0.62-0.74, p < 0.0005). The correlation between emphysema extent and spirometric lung function was weaker. No correlation between MRC, CCQ and objective measurements was found. V/P SPECT is sensitive to early changes in COPD. V/P SPECT also has the possibility to identify comorbid disease. V/P SPECT findings show a significant correlation with emphysema extent and spirometric lung function. We therefore recommend that scintigraphic signs of COPD, whenever found, should be

  13. Ventilation/perfusion SPECT in chronic obstructive pulmonary disease: an evaluation by reference to symptoms, spirometric lung function and emphysema, as assessed with HRCT

    International Nuclear Information System (INIS)

    Joegi, Jonas; Bajc, Marika; Ekberg, Marie; Jonson, Bjoern; Bozovic, Gracijela

    2011-01-01

    Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation which is not fully reversible. Despite the heterogeneity of COPD, its diagnosis and staging is currently based solely on forced expiratory volume in 1 s (FEV 1 ). FEV 1 does not explain the underlying pathophysiology of airflow limitation. The relationship between FEV 1 , symptoms and emphysema extent is weak. Better diagnostic tools are needed to define COPD. Tomographic lung scintigraphy [ventilation/perfusion single photon emission tomography (V/P SPECT)] visualizes regional V and P. In COPD, relations between V/P SPECT, spirometry, high-resolution computed tomography (HRCT) and symptoms have been insufficiently studied. The aim of this study was to investigate how lung function imaging and obstructive disease grading undertaken using V/P SPECT correlate with symptoms, spirometric lung function and degree of emphysema assessed with HRCT in patients with COPD. Thirty patients with stable COPD were evaluated with the Medical Research Council dyspnoea questionnaire (MRC) and the clinical COPD questionnaire (CCQ). Spirometry was performed. The extent of emphysema was assessed using HRCT. V/P SPECT was used to assess V/P patterns, total reduction in lung function and degree of obstructive disease. The total reduction in lung function and degree of obstructive disease, assessed with V/P SPECT, significantly correlated with emphysema extent (r = 0.66-0.69, p < 0.0001) and spirometric lung function (r = 0.62-0.74, p < 0.0005). The correlation between emphysema extent and spirometric lung function was weaker. No correlation between MRC, CCQ and objective measurements was found. V/P SPECT is sensitive to early changes in COPD. V/P SPECT also has the possibility to identify comorbid disease. V/P SPECT findings show a significant correlation with emphysema extent and spirometric lung function. We therefore recommend that scintigraphic signs of COPD, whenever found, should be reported. V

  14. The utility of the macro-aggregated albumin lung perfusion scan in the diagnosis and prognosis of hepatopulmonary syndrome in cirrhotic patients candidates for liver transplantation

    Directory of Open Access Journals (Sweden)

    Israel Grilo

    Full Text Available Background: The macro-aggregated albumin lung perfusion scan (99mTc-MAA is a diagnostic method for hepatopulmonary syndrome (HPS. Aim: To determine the sensitivity of 99mTc-MAA in diagnosing HPS, to establish the utility of 99mTc-MAA in determining the influence of HPS on hypoxemia in patients with concomitant pulmonary disease and to determine the correlation between 99mTc-MAA values and other respiratory parameters. Methods: Data from 115 cirrhotic patients who were eligible for liver transplantation (LT were prospectively analyzed. A transthoracic contrast echocardiography and 99mTc-MAA were performed in 85 patients, and 74 patients were diagnosed with HPS. Results: The overall sensitivity of 99mTc-MAA for the diagnosis of HPS was 18.9% (14/74 in all of the HPS cases and 66.7% (4/6 in the severe to very severe cases. In HPS patients who did not have lung disease, the degree of brain uptake of 99mTc-MAA was correlated with the alveolar-arterial oxygen gradient (A-a PO2 (r = 0.32, p < 0.05 and estimated oxygen shunt (r = 0.41, p < 0.05 and inversely correlated with partial pressure of arterial oxygen (PaO2 while breathing 100% O2 (r = -0.43, p < 0.05. The 99mTc-MAA was positive in 20.6% (7/36 of the patients with HPS and lung disease. The brain uptake of 99mTc-MAA was not associated with mortality and normalized in all cases six months after LT. Conclusions: The 99mTc-MAA is a low sensitivity test for the diagnosis of HPS that can be useful in patients who have concomitant lung disease and in severe to very severe cases of HPS. It was not related to mortality, and brain uptake normalized after LT.

  15. Acute tumor vascular effects following fractionated radiotherapy in human lung cancer: In vivo whole tumor assessment using volumetric perfusion computed tomography

    International Nuclear Information System (INIS)

    Ng, Q.-S.; Goh, Vicky; Milner, Jessica; Padhani, Anwar R.; Saunders, Michele I.; Hoskin, Peter J.

    2007-01-01

    Purpose: To quantitatively assess the in vivo acute vascular effects of fractionated radiotherapy for human non-small-cell lung cancer using volumetric perfusion computed tomography (CT). Methods and Materials: Sixteen patients with advanced non-small-cell lung cancer, undergoing palliative radiotherapy delivering 27 Gy in 6 fractions over 3 weeks, were scanned before treatment, and after the second (9 Gy), fourth (18 Gy), and sixth (27 Gy) radiation fraction. Using 16-detector CT, multiple sequential volumetric acquisitions were acquired after intravenous contrast agent injection. Measurements of vascular blood volume and permeability for the whole tumor volume were obtained. Vascular changes at the tumor periphery and center were also measured. Results: At baseline, lung tumor vascularity was spatially heterogeneous with the tumor rim showing a higher vascular blood volume and permeability than the center. After the second, fourth, and sixth fractions of radiotherapy, vascular blood volume increased by 31.6% (paired t test, p = 0.10), 49.3% (p = 0.034), and 44.6% (p = 0.0012) respectively at the tumor rim, and 16.4% (p = 0.29), 19.9% (p = 0.029), and 4.0% (p = 0.0050) respectively at the center of the tumor. After the second, fourth, and sixth fractions of radiotherapy, vessel permeability increased by 18.4% (p = 0.022), 44.8% (p = 0.0048), and 20.5% (p = 0.25) at the tumor rim. The increase in permeability at the tumor center was not significant after radiotherapy. Conclusion: Fractionated radiotherapy increases tumor vascular blood volume and permeability in human non-small-cell lung cancer. We have established the spatial distribution of vascular changes after radiotherapy; greater vascular changes were demonstrated at the tumor rim compared with the center

  16. Correlation between 11C-choline or 18F-FDG uptake and tumor proliferation: a rabbit bearing lung cancer model study

    International Nuclear Information System (INIS)

    Li Yajun; Bai Renju; Gao Shuo; Li Yansheng; Liu Lei; Jia Wei; Cai Li; Xing Xiling

    2009-01-01

    Objective: Tumor proliferative activity has been recognized as an indicator of malignant degree in lung cancer and related to prognosis. The purpose of this study was to evaluate the feasibility of assessing proliferative activity with 11 C-choline and 18 F-fluorodeoxyglucose (FDG) PET on a rabbit bearing lung VX2 tumor model. Methods: About 0.5 ml of viable VX2 tumor cell suspension was slowly injected into the right lungs of 54 New Zealand white rabbits through a transthoracical needle insertion. 11 C-choline and 18 F-FDG PET scan were performed 10-11 d after tumor implantation. One ear vein was cannulated for administration of the tracers, 11 C-choline PET scan (with Discovery LS PET/CT scanner, GE) was performed 5 rain after intravenously injection of 37 MBq 11 C-choline. Then 18.7 MBq 18 F-FDG was infused at 60 min after 11 C-choline administration and 18 F-FDG PET scan was performed at 60 min after 18 F-FDG administration. The maximal standardized uptake value of tumor was calculated. The animals were euthanized after examination. Histochemical stain with proliferating cell nuclear antigen (PCNA) was performed and PCNA index was obtained to assess tumor proliferation. The difference of 11 C-choline and 18 F-FDG was analyzed using paired student t-test. The correlation of 11 C-choline 18 F-FDG and tumor cell density and PCNA index was analyzed using Pearson linear regression. Results: Of the 54 rabbits, 36 had a solitary pulmonary tumor. The rate of successful generation of a solitary VX2 tumor was 66.7% (36/54). Only 33 rabbits underwent both 11 C-choline and 18 F-FDG PET, and enrolled in this study. The mean cellular density was (547.36 ± 64.78) cells/field and the mean PCNA index was (42.34 ± 15.26)%. 18 F-FDG was higher than 11 C-choline (5.70 ± 3.45 vs 4.02 ± 3.07, t=-3.188, P=0.003). 11 C-choline significantly and positively correlated with PCNA index (r=0.786, P 11 C-choline and tumor cellular density (r=-0.176, P=0.327). 18 F-FDG significantly and

  17. Perfusão pulmonar anterógrada "versus" retrógrada na preservação pulmonar para transplante em modelo canino de viabilidade pulmonar pós-morte Antegrade versus retrograde lung perfusion in pulmonary preservation for transplantation in a canine model of post-mortem lung viability

    Directory of Open Access Journals (Sweden)

    Jean Carlo Kohmann

    1999-04-01

    reperfusão (p = 0,01 e ao término do período de avaliação (p = 0,01. Os autores concluem que, neste modelo experimental, a perfusão retrógrada hipotérmica resulta em função superior do enxerto após 3 horas de isquemia normotérmica sob ventilação mecânica.Lung retrieval following cardio-circulatory arrest has been studied experimentally, however severe ischemia/reperfusion injury requires improved methods of graft preservation. Allograft perfusion with crystalloid solution delivered via pulmonary artery (antegrade perfusion remains the standard procedure, however it does not provide adequate washout of the blood retained within the bronchial circulation which may trigger reperfusion injury. This has led the authors to test the impact of antegrade versus retrograde (via left atrium perfusion of lung grafts submitted to 3 hours of warm ischemia after cardio-circulatory arrest in a dog model of left lung allotransplantation. Twelve donor dogs were sacrificed with thiopental sodium and kept under mechanical ventilation at room temperature for 3 hours. They were randomized and the heart-lung blocks harvested after being perfused in a retrograde (group I, n = 6 or antegrade (group II, n = 6 fashion with modified Euro-Collins solution. Twelve recipient animals were submitted to a left lung transplant receiving the grafts from both groups and the assessment was performed during 6 hours. Hemodynamic parameters were similar for animals in both groups. The gas exchange (arterial PaO2 and PaCO2 in recipients of group I (retrograde perfusion was significantly better when compared to recipients of grafts perfused via pulmonary artery. Intracellular ATP did not show difference between the groups, however there was a measurable drop in its values when samples obtained upon extraction were compared to those measured after reperfusion and at the end of the assessment. The authors concluded that retrograde perfusion yields better pulmonary function after 6 hours of reperfusion

  18. Integration of palmitat-1-14C in lecithine and phospholipid content in normal and micro-embolized rabbit lungs

    International Nuclear Information System (INIS)

    Wichert, P. von; Wilke, A.; Gaertner, U.

    1975-01-01

    Glass microspheres were used for a diffuse pulmonary microembolisation, as a modell for shock lung. Microembolisation is regarded as an important factor in pathogenesis of shock lung. The capacity of lung for lecithin synthesis was measured with palmitat-1- 14 C incorporation. The phospholipid content and the composition of the fatty acids of lecithine were investigated. From the results it was possible, that the surfactant system may alterated by the vascular blocking. The dates supporting the importance of microembolisation in pathogenesis of shock lung. (orig.) [de

  19. Intra-observer and inter-observer agreements for the measurement of dual-input whole tumor computed tomography perfusion in patients with lung cancer: Influences of the size and inner-air density of tumors.

    Science.gov (United States)

    Wang, Qingle; Zhang, Zhiyong; Shan, Fei; Shi, Yuxin; Xing, Wei; Shi, Liangrong; Zhang, Xingwei

    2017-09-01

    This study was conducted to assess intra-observer and inter-observer agreements for the measurement of dual-input whole tumor computed tomography perfusion (DCTP) in patients with lung cancer. A total of 88 patients who had undergone DCTP, which had proved a diagnosis of primary lung cancer, were divided into two groups: (i) nodules (diameter ≤3 cm) and masses (diameter >3 cm) by size, and (ii) tumors with and without air density. Pulmonary flow, bronchial flow, and pulmonary index were measured in each group. Intra-observer and inter-observer agreements for measurement were assessed using intraclass correlation coefficient, within-subject coefficient of variation, and Bland-Altman analysis. In all lung cancers, the reproducibility coefficient for intra-observer agreement (range 26.1-38.3%) was superior to inter-observer agreement (range 38.1-81.2%). Further analysis revealed lower agreements for nodules compared to masses. Additionally, inner-air density reduced both agreements for lung cancer. The intra-observer agreement for measuring lung cancer DCTP was satisfied, while the inter-observer agreement was limited. The effects of tumoral size and inner-air density to agreements, especially between two observers, should be emphasized. In future, an automatic computer-aided segment of perfusion value of the tumor should be developed. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  20. The multi-slice CT perfusion imaging in evaluating the prevention and treatment by edaravone on lung ischemia-reperfusion injury after pulmonary thromboembolism

    Energy Technology Data Exchange (ETDEWEB)

    Jianjun, Li; Renyou, Zhai; Dongpo, Zhang; Qiang, Huang; Dingke, Dai; Ping, Yu; Na, Bao [Department of Radiology, Beijing Chaoyang Hospital, Capital Medical Univ., Beijing (China)

    2008-10-15

    Objective: To evaluate the multi-slice CT perfusion imaging in investigating whether edaravone can prevent and treat pulmonary thromboembolism ischemia-reperfusion injury (PTE-IRI). Methods: Twenty mongrel canines were included. A Swan-Ganz catheter was introduced into the right internal jugular vein using the Seldinger technique, and then was inserted into the pulmonary artery. Balloon occlusion of the right inferior lobe pulmonary artery for 4 h was followed by removing catheter and 4 h o reperfusion. Animals were divided into four groups of A (no edaravone during ischenmia and reperfusion), B (edaravone used only during ischemia), C (edaravone used during both ischemia and reperfusion) and D group (edaravone used only during reperfusion) (n=5 per group). Every group was divided into three time points including before ischemia, 4 h after ischemia and 4 h after reperfusion. CT scan and CT perfusion were performed at the three time points. The blood flow (BF), blood volume (BV) and mean transit time (MTT) of the bilateral inferior regional lung parenchyma were measured with the software of perfusion 3. Results: CT examination showed pulmonary edema in the right inferior lung lobe at 4 h after reperfusion. (1) The BF and MTT of A, B, C and D group were[(259.4{+-}15.7)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1}, (293.7{+-} 7.9) ml{center_dot}min{sup -1{center_dot}}100 g {sup -1}, (379.4{+-}14.5)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1}, (382.5{+-}16.6)ml{center_dot}min{sup -1{center_dot}}. 100 g{sup -1}] and [(3.1{+-}0.2)s, (2.6{+-}0.2)s, (2.2{+-}0.1)s, (1.9{+-}0.2)s] respectively at 4 h after reperfusion. The BF and MTT were statistically different (P<0.01) between groups (A and B, A and C, A and D, B and C, B and D) except between group C and D (the P value >0.05) at 4 h after reperfusion, but the BV was not statistically different between groups (P>0.05). (2) The BF [(397.2{+-} 19.2)ml{center_dot}min{sup -1{center_dot}}100 g{sup -1} and (259

  1. The multi-slice CT perfusion imaging in evaluating the prevention and treatment by edaravone on lung ischemia-reperfusion injury after pulmonary thromboembolism

    International Nuclear Information System (INIS)

    Li Jianjun; Zhai Renyou; Zhang Dongpo; Huang Qiang; Dai Dingke; Yu Ping; Bao Na

    2008-01-01

    Objective: To evaluate the multi-slice CT perfusion imaging in investigating whether edaravone can prevent and treat pulmonary thromboembolism ischemia-reperfusion injury (PTE-IRI). Methods: Twenty mongrel canines were included. A Swan-Ganz catheter was introduced into the right internal jugular vein using the Seldinger technique, and then was inserted into the pulmonary artery. Balloon occlusion of the right inferior lobe pulmonary artery for 4 h was followed by removing catheter and 4 h o reperfusion. Animals were divided into four groups of A (no edaravone during ischenmia and reperfusion), B (edaravone used only during ischemia), C (edaravone used during both ischemia and reperfusion) and D group (edaravone used only during reperfusion) (n=5 per group). Every group was divided into three time points including before ischemia, 4 h after ischemia and 4 h after reperfusion. CT scan and CT perfusion were performed at the three time points. The blood flow (BF), blood volume (BV) and mean transit time (MTT) of the bilateral inferior regional lung parenchyma were measured with the software of perfusion 3. Results: CT examination showed pulmonary edema in the right inferior lung lobe at 4 h after reperfusion. (1) The BF and MTT of A, B, C and D group were[(259.4±15.7)ml·min -1 ·100 g -1 , (293.7± 7.9) ml·min -1 ·100 g -1 , (379.4±14.5)ml·min -1 ·100 g -1 , (382.5±16.6)ml·min -1 ·. 100 g -1 ] and [(3.1±0.2)s, (2.6±0.2)s, (2.2±0.1)s, (1.9±0.2)s] respectively at 4 h after reperfusion. The BF and MTT were statistically different (P 0.05) at 4 h after reperfusion, but the BV was not statistically different between groups (P>0.05). (2) The BF [(397.2± 19.2)ml·min -1 ·100 g -1 and (259.4±15.7) ml·min -1 ·100 g -1 in group A, (393.2±16.1) ml· min -1 ·100 g -1 and (293.7±7.9) ml·min -1 ·100 g -1 in group B] and MTF [(1.8±0.1)s and (3.1±0.2) s in group A, (1.8±0.2) s and (2.6±0.2) s in group B] were statistically different (P 0.05) between groups

  2. WE-G-18C-02: Estimation of Optimal B-Value Set for Obtaining Apparent Diffusion Coefficient Free From Perfusion in Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Karki, K; Hugo, G; Ford, J; Saraiya, S; Weiss, E [Radiation Oncology, Virginia Commonwealth University, Richmond, VA (United States); Olsen, K; Groves, R [Radiology, Virginia Commonwealth University, Richmond, VA (United States)

    2014-06-15

    Purpose: Diffusion-weighted MRI (DW-MRI) is increasingly being investigated for radiotherapy planning and response assessment. Selection of a limited number of b-values in DW-MRI is important to keep geometrical variations low and imaging time short. We investigated various b-value sets to determine an optimal set for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADCIVIM) in nonsmall cell lung cancer. Methods: Seven patients had 27 DW-MRI scans before and during radiotherapy in a 1.5T scanner. Respiratory triggering was applied to the echo-planar DW-MRI with TR=4500ms approximately, TE=74ms, pixel size=1.98X1.98mm{sub 2}, slice thickness=4–6mm and 7 axial slices. Diffusion gradients were applied to all three axes producing traceweighted images with eight b-values of 0–1000μs/μm{sup 2}. Monoexponential model ADC values using various b-value sets were compared to ADCIVIM using all b-values. To compare the relative noise in ADC maps, intra-scan coefficient of variation (CV) of active tumor volumes was computed. Results: ADCIVIM, perfusion coefficient and perfusion fraction for tumor volumes were in the range of 880-1622 μm{sup 2}/s, 8119-33834 μm{sup 2}/s and 0.104–0.349, respectively. ADC values using sets of 250, 800 and 1000; 250, 650 and 1000; and 250–1000μs/μm{sup 2} only were not significantly different from ADCIVIM(p>0.05, paired t-test). Error in ADC values for 0–1000, 50–1000, 100–1000, 250–1000, 500–1000, and three b-value sets- 250, 500 and 1000; 250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2} were 15.0, 9.4, 5.6, 1.4, 11.7, 3.7, 2.0 and 0.2% relative to the reference-standard ADCIVIM, respectively. Mean intrascan CV was 20.2, 20.9, 21.9, 24.9, 32.6, 25.8, 25.4 and 24.8%, respectively, whereas that for ADCIVIM was 23.3%. Conclusion: ADC values of two 3 b-value sets

  3. Autoradiographic observations of the induced vascular injuries by arachidonic acid in rabbit's brain and lung using 111In-oxine labeled platelets

    International Nuclear Information System (INIS)

    Fujimoto, Tsukasa; Fukushima, Yoshiharu; Suzuki, Hidenori; Kuroiwa, Kyoko; Tanoue, Kenjiro; Yamazaki, Hiroh.

    1985-01-01

    Autoradiography using 111 In-oxine labeled autologous platelets was performed to observe the behavior of platelets in induced vascular injury by activated platelets in rabbit's brain and lung. Cerebrovascular injuries were induced by injection of arachidonic acid (AA) (0.7 mg/kg) into right internal carotid artery. Fourteen animals were pretreated with antiplatelet drug, ticlopidine (200 mg/kg) and 10 were controls. Before the AA injection, 111 In-oxine (300 μCi) labeled platelets were injected intravenously. Evans blue was given as a marker of disturbances of blood brain barrier. Sixty min after the AA injection, brains were removed and autoradiographic and electron microscopic studies were done. In the nontreated animals and some of the treated animals whose platelet aggregability was not suppressed, blue staining were seen in the cerebral hemisphere of injection side and hot radioactivity in autoradiogram were revealed in corresponding area. In the treated animals whose platelet aggregability was remarkably suppressed, no or slight blue staining or radioactivity were recognized. Only in hot radioactive area, platelet thrombi and vascular injuries were seen. Vascular injuries of lung were produced by decompression after keeping animals under hyperbalic condition (6 atomosphere absolute for 40 min). Before this procedure, 111 In-oxine labeled platelets were injected. Lungs of both 4 control and 4 decompression sickness animals were removed and autoradiographic and lightmicroscopic observations were performed. In lungs of decompression sickness animals remarkable spotty high radioactivity and prominent platelet aggregates in the vessels were seen. These findings were not seen in control animals. Our results suggested important roles of platelets in induced vascular injuries. And this autoradiographic approach seemed to be quite useful for observation of platelet's behavior in injured vessels and evaluation of antiplatelet drugs. (author)

  4. Detection of pulmonary fat embolism with dual-energy CT: an experimental study in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chun Xiang; Zhou, Chang Sheng; Zhao, Yan E.; Han, Zong Hong; Qi, Li; Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Mangold, Stefanie; Ball, B.D. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2017-04-15

    To evaluate the use of dual-energy CT imaging of the lung perfused blood volume (PBV) for the detection of pulmonary fat embolism (PFE). Dual-energy CT was performed in 24 rabbits before and 1 hour, 1 day, 4 days and 7 days after artificial induction of PFE via the right ear vein. CT pulmonary angiography (CTPA) and lung PBV images were evaluated by two radiologists, who recorded the presence, number, and location of PFE on a per-lobe basis. Sensitivity, specificity, and accuracy of CTPA and lung PBV for detecting PFE were calculated using histopathological evaluation as the reference standard. A total of 144 lung lobes in 24 rabbits were evaluated and 70 fat emboli were detected on histopathological analysis. The overall sensitivity, specificity and accuracy were 25.4 %, 98.6 %, and 62.5 % for CTPA, and 82.6 %, 76.0 %, and 79.2 % for lung PBV. Higher sensitivity (p < 0.001) and accuracy (p < 0.01), but lower specificity (p < 0.001), were found for lung PBV compared with CTPA. Dual-energy CT can detect PFE earlier than CTPA (all p < 0.01). Dual-energy CT provided higher sensitivity and accuracy in the detection of PFE as well as earlier detection compared with conventional CTPA in this animal model study. (orig.)

  5. Prospective study on the behaviour of values obtained by organ function studies, in particular scintiscan studies of pulmonary perfusion, during treatment of little to moderately advanced tuberculosis, shown by X-rays to involve one lobe of the lung

    International Nuclear Information System (INIS)

    Schaffartzik, W.

    1987-01-01

    Prospective study on the behaviour of values obtained by organ function studies, in particular scintiscan studies of pulmonary perfusion, during treatment of little to moderately advanced tuberculosis, shown by X-rays to involve one lobe of the lung. This prospective study analyses features of global and regional pulmonary function in 14 patients with little to moderately pronounced tuberculosis, shown by X-rays to involve one lobe of the lung. At the beginning of treatment, the global function values were not different from the values generally accepted as normal. Disturbed perfusion was determined in pulmonary sections where the X-ray pictures had revealed the presence of tuberculous foci. After therapy and inactivation of the tuberculosis the values were seen to remain unchanged. (MBC) [de

  6. Beware Cold Agglutinins in Organ Donors! Ex Vivo Lung Perfusion From an Uncontrolled Donation After Circulatory-Determination-of-Death Donor With a Cold Agglutinin: A Case Report.

    Science.gov (United States)

    Venkataraman, A; Blackwell, J W; Funkhouser, W K; Birchard, K R; Beamer, S E; Simmons, W T; Randell, S H; Egan, T M

    2017-09-01

    We began to recover lungs from uncontrolled donation after circulatory determination of death to assess for transplant suitability by means of ex vivo lung perfusion (EVLP) and computerized tomographic (CT) scan. Our first case had a cold agglutinin with an interesting outcome. A 60-year-old man collapsed at home and was pronounced dead by Emergency Medical Services personnel. Next-of-kin consented to lung retrieval, and the decedent was ventilated and transported. Lungs were flushed with cold Perfadex, removed, and stored cold. The lungs did not flush well. Medical history revealed a recent hemolytic anemia and a known cold agglutinin. Warm nonventilated ischemia time was 51 minutes. O 2 -ventilated ischemia time was 141 minutes. Total cold ischemia time was 6.5 hours. At cannulation for EVLP, established clots were retrieved from both pulmonary arteries. At initiation of EVLP with Steen solution, tiny red aggregates were observed initially. With warming, the aggregates disappeared and the perfusate became red. After 1 hour, EVLP was stopped because of florid pulmonary edema. The lungs were cooled to 20°C; tiny red aggregates formed again in the perfusate. Ex vivo CT scan showed areas of pulmonary edema and a pyramidal right middle lobe opacity. Dissection showed multiple pulmonary emboli-the likely cause of death. However, histology showed agglutinated red blood cells in the microvasculature in pre- and post-EVLP biopsies, which may have contributed to inadequate parenchymal preservation. Organ donors with cold agglutinins may not be suitable owing to the impact of hypothermic preservation. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Dynamic Contrast-Enhanced Perfusion Area-Detector CT: Preliminary Comparison of Diagnostic Performance for N Stage Assessment With FDG PET/CT in Non-Small Cell Lung Cancer.

    Science.gov (United States)

    Ohno, Yoshiharu; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Yoshikawa, Takeshi

    2017-11-01

    The objective of our study was to directly compare the capability of dynamic first-pass contrast-enhanced (CE) perfusion area-detector CT (ADCT) and FDG PET/CT for differentiation of metastatic from nonmetastatic lymph nodes and assessment of N stage in patients with non-small cell lung carcinoma (NSCLC). Seventy-seven consecutive patients, 45 men (mean age ± SD, 70.4 ± 5.9 years) and 32 women (71.2 ± 7.7 years), underwent dynamic first-pass CE-perfusion ADCT at two or three different positions for covering the entire thorax, FDG PET/CT, surgical treatment, and pathologic examination. From all ADCT data for each of the subjects, a whole-chest perfusion map was computationally generated using the dual- and single-input maximum slope and Patlak plot methods. For quantitative N stage assessment, perfusion parameters and the maximum standardized uptake value (SUV max ) for each lymph node were determined by measuring the relevant ROI. ROC curve analyses were performed for comparing the diagnostic capability of each of the methods on a per-node basis. N stages evaluated by each of the indexes were then statistically compared with the final pathologic diagnosis by means of chi-square and kappa statistics. The area under the ROC curve (A z ) values of systemic arterial perfusion (A z = 0.89), permeability surface (A z = 0.78), and SUV max (A z = 0.85) were significantly larger than the A z values of total perfusion (A z = 0.70, p Dynamic first-pass CE-perfusion ADCT is as useful as FDG PET/CT for the differentiation of metastatic from nonmetastatic lymph nodes and assessment of N stage in patients with NSCLC.

  8. Lung scintigraphy; Centellograma pulmonar

    Energy Technology Data Exchange (ETDEWEB)

    Dalenz, Roberto

    1994-12-31

    A review of lung scintigraphy, perfusion scintigraphy with SPECT, lung ventilation SPECT, blood pool SPECT. The procedure of lung perfusion studies, radiopharmaceutical, administration and clinical applications, imaging processing .Results encountered and evaluation criteria after Biello and Pioped. Recommendations and general considerations have been studied about relation of this radiopharmaceutical with other pathologies.

  9. Perfusion- and pattern-based quantitative CT indexes using contrast-enhanced dual-energy computed tomography in diffuse interstitial lung disease: relationships with physiologic impairment and prediction of prognosis

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jung Won [Sungkyunkwan University School of Medicine, Department of Radiology, Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Bae, Jang Pyo; Kim, Namkug; Chang, Yongjun; Seo, Joon Beom [University of Ulsan College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Lee, Ho Yun; Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Chung, Man Pyo; Park, Hye Yun [Sungkyunkwan University School of Medicine, Department of Pulmonology, Samsung Medical Center, Seoul (Korea, Republic of)

    2016-05-15

    To evaluate automated texture-based segmentation of dual-energy CT (DECT) images in diffuse interstitial lung disease (DILD) patients and prognostic stratification by overlapping morphologic and perfusion information of total lung. Suspected DILD patients scheduled for surgical biopsy were prospectively included. Texture patterns included ground-glass opacity (GGO), reticulation and consolidation. Pattern- and perfusion-based CT measurements were assessed to extract quantitative parameters. Accuracy of texture-based segmentation was analysed. Correlations between CT measurements and pulmonary function test or 6-minute walk test (6MWT) were calculated. Parameters of idiopathic pulmonary fibrosis/usual interstitial pneumonia (IPF/UIP) and non-IPF/UIP were compared. Survival analysis was performed. Overall accuracy was 90.47 % for whole lung segmentation. Correlations between mean iodine values of total lung, 50-97.5th (%) attenuation and forced vital capacity or 6MWT were significant. Volume of GGO, reticulation and consolidation had significant correlation with DLco or SpO{sub 2} on 6MWT. Significant differences were noted between IPF/UIP and non-IPF/UIP in 6MWT distance, mean iodine value of total lung, 25-75th (%) attenuation and entropy. IPF/UIP diagnosis, GGO ratio, DILD extent, 25-75th (%) attenuation and SpO{sub 2} on 6MWT showed significant correlations with survival. DECT combined with pattern analysis is useful for analysing DILD and predicting survival by provision of morphology and enhancement. (orig.)

  10. To Find a Better Dosimetric Parameter in the Predicting of Radiation-Induced Lung Toxicity Individually: Ventilation, Perfusion or CT based.

    Science.gov (United States)

    Xiao, Lin-Lin; Yang, Guoren; Chen, Jinhu; Wang, Xiaohui; Wu, Qingwei; Huo, Zongwei; Yu, Qingxi; Yu, Jinming; Yuan, Shuanghu

    2017-03-15

    This study aimed to find a better dosimetric parameter in predicting of radiation-induced lung toxicity (RILT) in patients with non-small cell lung cancer (NSCLC) individually: ventilation(V), perfusion (Q) or computerized tomography (CT) based. V/Q single-photon emission computerized tomography (SPECT) was performed within 1 week prior to radiotherapy (RT). All V/Q imaging data was integrated into RT planning system, generating functional parameters based on V/Q SPECT. Fifty-seven NSCLC patients were enrolled in this prospective study. Fifteen (26.3%) patients underwent grade ≥2 RILT, the remaining forty-two (73.7%) patients didn't. Q-MLD, Q-V20, V-MLD, V-V20 of functional parameters correlated more significantly with the occurrence of RILT compared to V20, MLD of anatomical parameters (r = 0.630; r = 0.644; r = 0.617; r = 0.651 vs. r = 0.424; r = 0.520 p < 0.05, respectively). In patients with chronic obstructive pulmonary diseases (COPD), V functional parameters reflected significant advantage in predicting RILT; while in patients without COPD, Q functional parameters reflected significant advantage. Analogous results were existed in fractimal analysis of global pulmonary function test (PFT). In patients with central-type NSCLC, V parameters were better than Q parameters; while in patients with peripheral-type NSCLC, the results were inverse. Therefore, this study demonstrated that choosing a suitable dosimetric parameter individually can help us predict RILT accurately.

  11. MRI of pulmonary perfusion; MRT der Lungenperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie, Heidelberg (Germany); Risse, F.; Semmler, W. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Medizinische Physik in der Radiologie, Heidelberg (Germany); Schoenberg, S.O.; Reiser, M.F. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen (Germany). Institut fuer Klinische Radiologie; Kauczor, H.-U. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung Radiologie, Heidelberg (Germany)

    2006-04-15

    Lung perfusion is a crucial prerequisite for effective gas exchange. Quantification of pulmonary perfusion is important for diagnostic considerations and treatment planning in various diseases of the lungs. Besides disorders of pulmonary vessels such as acute pulmonary embolism and pulmonary hypertension, these also include diseases of the respiratory tract and lung tissue as well as pulmonary tumors. This contribution presents the possibilities and technical requirements of MRI for diagnostic work-up of pulmonary perfusion. (orig.) [German] Die Perfusion der Lunge ist eine entscheidende Voraussetzung fuer einen effektiven Gasaustausch. Die Bestimmung der Lungenperfusion ist bei verschiedenen Erkrankungen der Lunge fuer Diagnostik und Therapieplanung bedeutsam. Hierzu zaehlen neben Erkrankungen der Lungengefaesse wie akute Lungenembolie und pulmonale Hypertension ebenso Erkrankungen der Atemwege, des Lungengeruests und Lungentumoren. In diesem Beitrag werden die Moeglichkeiten und technischen Voraussetzungen der MRT zur Diagnostik der Lungenperfusion dargestellt. (orig.)

  12. Neurally adjusted ventilatory assist decreases ventilator-induced lung injury and non-pulmonary organ dysfunction in rabbits with acute lung injury

    NARCIS (Netherlands)

    Brander, Lukas; Sinderby, Christer; Lecomte, François; Leong-Poi, Howard; Bell, David; Beck, Jennifer; Tsoporis, James N.; Vaschetto, Rosanna; Schultz, Marcus J.; Parker, Thomas G.; Villar, Jesús; Zhang, Haibo; Slutsky, Arthur S.

    2009-01-01

    OBJECTIVE: To determine if neurally adjusted ventilatory assist (NAVA) that delivers pressure in proportion to diaphragm electrical activity is as protective to acutely injured lungs (ALI) and non-pulmonary organs as volume controlled (VC), low tidal volume (Vt), high positive end-expiratory

  13. Renal perfusion scintiscan

    Science.gov (United States)

    ... Radionuclide renal perfusion scan; Perfusion scintiscan - renal; Scintiscan - renal perfusion Images Kidney anatomy Kidney - blood and urine flow Intravenous pyelogram References Rottenberg G, Andi AC. Renal ...

  14. Lung scintigraphy in differential diagnosis of peripheral lung cancer and community-acquired pneumonia

    Science.gov (United States)

    Krivonogov, Nikolay G.; Efimova, Nataliya Y.; Zavadovsky, Konstantin W.; Lishmanov, Yuri B.

    2016-08-01

    Ventilation/perfusion lung scintigraphy was performed in 39 patients with verified diagnosis of community-acquired pneumonia (CAP) and in 14 patients with peripheral lung cancer. Ventilation/perfusion ratio, apical-basal gradients of ventilation (U/L(V)) and lung perfusion (U/L(P)), and alveolar capillary permeability of radionuclide aerosol were determined based on scintigraphy data. The study demonstrated that main signs of CAP were increases in ventilation/perfusion ratio, perfusion and ventilation gradient on a side of the diseased lung, and two-side increase in alveolar capillary permeability rate for radionuclide aerosol. Unlike this, scintigraphic signs of peripheral lung cancer comprise an increase in ventilation/perfusion ratio over 1.0 on a side of the diseased lung with its simultaneous decrease on a contralateral side, normal values of perfusion and ventilation gradients of both lungs, and delayed alveolar capillary clearance in the diseased lung compared with the intact lung.

  15. Lung scintigraphy in differential diagnosis of peripheral lung cancer and community-acquired pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Krivonogov, Nikolay G., E-mail: kng@cardio-tomsk.ru [Research Institute of Cardiology, Kievskaya Street 111a, Tomsk, 634012 (Russian Federation); Efimova, Nataliya Y., E-mail: efimova@cardio-tomsk.ru; Zavadovsky, Konstantin W.; Lishmanov, Yuri B. [Research Institute of Cardiology, Kievskaya Street 111a, Tomsk, 634012 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation)

    2016-08-02

    Ventilation/perfusion lung scintigraphy was performed in 39 patients with verified diagnosis of community-acquired pneumonia (CAP) and in 14 patients with peripheral lung cancer. Ventilation/perfusion ratio, apical-basal gradients of ventilation (U/L(V)) and lung perfusion (U/L(P)), and alveolar capillary permeability of radionuclide aerosol were determined based on scintigraphy data. The study demonstrated that main signs of CAP were increases in ventilation/perfusion ratio, perfusion and ventilation gradient on a side of the diseased lung, and two-side increase in alveolar capillary permeability rate for radionuclide aerosol. Unlike this, scintigraphic signs of peripheral lung cancer comprise an increase in ventilation/perfusion ratio over 1.0 on a side of the diseased lung with its simultaneous decrease on a contralateral side, normal values of perfusion and ventilation gradients of both lungs, and delayed alveolar capillary clearance in the diseased lung compared with the intact lung.

  16. Magnetic resonance perfusion imaging without contrast media

    International Nuclear Information System (INIS)

    Martirosian, Petros; Graf, Hansjoerg; Schick, Fritz; Boss, Andreas; Schraml, Christina; Schwenzer, Nina F.; Claussen, Claus D.

    2010-01-01

    Principles of magnetic resonance imaging techniques providing perfusion-related contrast weighting without administration of contrast media are reported and analysed systematically. Especially common approaches to arterial spin labelling (ASL) perfusion imaging allowing quantitative assessment of specific perfusion rates are described in detail. The potential of ASL for perfusion imaging was tested in several types of tissue. After a systematic comparison of technical aspects of continuous and pulsed ASL techniques the standard kinetic model and tissue properties of influence to quantitative measurements of perfusion are reported. For the applications demonstrated in this paper a flow-sensitive alternating inversion recovery (FAIR) ASL perfusion preparation approach followed by true fast imaging with steady precession (true FISP) data recording was developed and implemented on whole-body scanners operating at 0.2, 1.5 and 3 T for quantitative perfusion measurement in various types of tissue. ASL imaging provides a non-invasive tool for assessment of tissue perfusion rates in vivo. Images recorded from kidney, lung, brain, salivary gland and thyroid gland provide a spatial resolution of a few millimetres and sufficient signal to noise ratio in perfusion maps after 2-5 min of examination time. Newly developed ASL techniques provide especially high image quality and quantitative perfusion maps in tissues with relatively high perfusion rates (as also present in many tumours). Averaging of acquisitions and image subtraction procedures are mandatory, leading to the necessity of synchronization of data recording to breathing in abdominal and thoracic organs. (orig.)

  17. Ventilation-perfused studies using SPECT

    International Nuclear Information System (INIS)

    Zwijnenburg, A.

    1989-01-01

    A method for the quantitative analysis of ventilation-perfusion SPECT studies is decribed and an effort is made to evaluate its usefullness. The technical details of the emthod are described. In the the transaxial reconstructions of the tomographic studies the contour of the lungs is detected and regional values of lung volume, ventilation, perfusion and ventilation-perfusion ratios are calculated. The method is operator independent. The lung volume calculations from the SPECT studies are validated by comparing them with lung volume measurements using the helium dilution technique. A good correlation (r=0.91) was found between the two volumes. SPECT volume was greater than the volume measured with helium dilution, which was attributed to non-gas-containing structures in the. lungs. The use of ventilation-perfusion ratio SPECT is described to evaluate the effect of ionizing radiation on the lungs in patients treated with mantle field irradiation for Hodgkin's disease. Perfusion changes appear as early as 2 months after the start of irradiation. Ventilation changes appear later and relatively minor. No changes are seen outside the radiation portals. The ventilation-perfusion inequality in pulmonary sarcoidosis is treated. It is suggested that the decrease D LCO in these patients may be partly due to an even distribution of ventilation perfusion ratios. An effort is made to establish the properties of a new tracer used for the assessment of the metabolic function of the pulmonary endothelium. The lung uptake of I-123 IMP mimics the distribution of a perfusion tracer and it is suggested that this tracer may be useful for the early detection of pulmonary vascular damage, even when blood flow is still intact. Some aspects of the use of Kr-81m as a ventilation tracer are discussed as well as the effect of noise on Kr-81m SPECT reconstructions. (author). 146 refs.; 39 figs.; 8 tabs

  18. Perfusion abnormalities in congenital and neoplastic pulmonary disease: comparison of MR perfusion and multislice CT imaging

    International Nuclear Information System (INIS)

    Boll, Daniel T.; Lewin, Jonathan S.; Young, Philip; Gilkeson, Robert C.; Siwik, Ernest S.

    2005-01-01

    The aim of this work was to assess magnetic resonance (MR) perfusion patterns of chronic, nonembolic pulmonary diseases of congenital and neoplastic origin and to compare the findings with results obtained with pulmonary, contrast-enhanced multislice computed tomography (CT) imaging to prove that congenital and neoplastic pulmonary conditions require MR imaging over the pulmonary perfusion cycle to successfully and directly detect changes in lung perfusion patterns. Twenty-five patients underwent concurrent CT and MR evaluation of chronic pulmonary diseases of congenital (n=15) or neoplastic (n=10) origin. Analysis of MR perfusion and contrast-enhanced CT datasets was realized by defining pulmonary and vascular regions of interest in corresponding positions. MR perfusion calculated time-to-peak enhancement, maximal enhancement and the area under the perfusion curve. CT datasets provided pulmonary signal-to-noise ratio measurements. Vessel centerlines of bronchial arteries were determined. Underlying perfusion type, such as pulmonary arterial or systemic arterial supply, as well as regions with significant variations in perfusion were determined statistically. Analysis of the pulmonary perfusion pattern detected pulmonary arterial supply in 19 patients; six patients showed systemic arterial supply. In pulmonary arterial perfusion, MR and multislice CT imaging consistently detected the perfusion type and regions with altered perfusion patterns. In bronchial arterial supply, MR perfusion and CT imaging showed significant perfusion differences. Patients with bronchial arterial supply had bronchial arteries ranging from 2.0 to 3.6 mm compared with submillimeter diameters in pulmonary arterial perfusion. Dynamic MR imaging of congenital and neoplastic pulmonary conditions allowed characterization of the pulmonary perfusion type. CT imaging suggested the presence of systemic arterial perfusion by visualizing hypertrophied bronchial arteries. (orig.)

  19. Methodology for ventilation/perfusion SPECT

    DEFF Research Database (Denmark)

    Bajc, Marika; Neilly, Brian; Miniati, Massimo

    2010-01-01

    radiolabeled liquid aerosols are not restricted to the presence of obstructive lung disease. Radiolabeled macroaggregated human albumin is the imaging agent of choice for perfusion scintigraphy. An optimal combination of nuclide activities and acquisition times for ventilation and perfusion, collimators......Ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) is the scintigraphic technique of choice for the diagnosis of pulmonary embolism and many other disorders that affect lung function. Data from recent ventilation studies show that the theoretic advantages of Technegas over......, and imaging matrix yields an adequate V/Q SPECT study in approximately 20 minutes of imaging time. The recommended protocol based on the patient remaining in an unchanged position during the initial ventilation study and the perfusion study allows presentation of matching ventilation and perfusion slices...

  20. Pulmonary perfusion ''without ventilation''

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, C.N.; Sziklas, J.J.; Spencer, R.P.; Rosenberg, R.J.

    1983-12-01

    An 88-yr-old man, with prior left upper lobectomy and phrenic nerve injury, had a ventilation/perfusion lung image. Both wash-in and equilibrium ventilation images showed no radioactive gas in the left lung. Nevertheless, the left lung was perfused. A similar result was obtained on a repeat study 8 days later. Delayed images, during washout, showed some radioactive gas in the left lung. Nearly absent ventilation (but continued perfusion) of that lung might have been related to altered gas dynamics brought about by the prior lobectomy, a submucosal bronchial lesion, phrenic nerve damage, and limited motion of the left part of the diaphragm. This case raises the issue of the degree of ventilation (and the phase relationship between the lungs) required for the entry of radioactive gas into a diseased lung, and the production of a ''reversed ventilation/perfusion mismatch.''

  1. Modelo experimental de perfusão pulmonar ex vivo em ratos: avaliação histopatológica e de apoptose celular em pulmões preservados com solução de baixo potássio dextrana vs. solução histidina-triptofano-cetoglutarato An experimental rat model of ex vivo lung perfusion for the assessment of lungs regarding histopathological findings and apoptosis: low-potassium dextran vs. histidine-tryptophan-ketoglutarate

    Directory of Open Access Journals (Sweden)

    Edson Azevedo Simões

    2012-08-01

    Full Text Available OBJETIVO: Comparar os achados histopatológicos e de apoptose em pulmões de ratos preservados em soluções low-potassium dextran (LPD, baixo potássio dextrana, histidine-tryptophan-ketoglutarate (HTK, histidina-triptofano-cetoglutarato ou salina normal (SN em 6 h e 12 h de isquemia pela utilização de um modelo experimental de perfusão pulmonar ex vivo. MÉTODOS: Sessenta ratos Wistar foram anestesiados, randomizados e submetidos à perfusão anterógrada pela artéria pulmonar com uma das soluções preservadoras. Após a extração, os blocos cardiopulmonares foram preservados por 6 ou 12 h a 4ºC, sendo então reperfundidos com sangue homólogo em um sistema de perfusão ex vivo durante 60 min. Ao final da reperfusão, fragmentos do lobo médio foram extraídos e processados para histopatologia, sendo avaliados os seguintes parâmetros: congestão, edema alveolar, hemorragia alveolar, hemorragia, infiltrado inflamatório e infiltrado intersticial. O grau de apoptose foi avaliado pelo método TdT-mediated dUTP nick end labeling. RESULTADOS: A histopatologia demonstrou que todos os pulmões preservados com SN apresentaram edema alveolar após 12 h de isquemia. Não houve diferenças em relação ao grau de apoptose nos grupos estudados. CONCLUSÕES: No presente estudo, os achados histopatológicos e de apoptose foram semelhantes com o uso das soluções LPD e HTK, enquanto a presença de edema foi significativamente maior com o uso de SN.OBJECTIVE: To compare histopathological findings and the degree of apoptosis among rat lungs preserved with low-potassium dextran (LPD solution, histidine-tryptophan-ketoglutarate (HTK solution, or normal saline (NS at two ischemia periods (6 h and 12 h using an experimental rat model of ex vivo lung perfusion. METHODS: Sixty Wistar rats were anesthetized, randomized, and submitted to antegrade perfusion via pulmonary artery with one of the preservation solutions. Following en bloc extraction, the heart-lung

  2. Estimation of optimal b-value sets for obtaining apparent diffusion coefficient free from perfusion in non-small cell lung cancer.

    Science.gov (United States)

    Karki, Kishor; Hugo, Geoffrey D; Ford, John C; Olsen, Kathryn M; Saraiya, Siddharth; Groves, Robert; Weiss, Elisabeth

    2015-10-21

    The purpose of this study was to determine optimal sets of b-values in diffusion-weighted MRI (DW-MRI) for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADCIVIM) in non-small cell lung cancer. Ten subjects had 40 DW-MRI scans before and during radiotherapy in a 1.5 T MRI scanner. Respiratory triggering was applied to the echo-planar DW-MRI with TR ≈ 4500 ms, TE  =  74 ms, eight b-values of 0-1000 μs μm(-2), pixel size  =  1.98 × 1.98 mm(2), slice thickness  =  6 mm, interslice gap  =  1.2 mm, 7 axial slices and total acquisition time ≈6 min. One or more DW-MRI scans together covered the whole tumour volume. Monoexponential model ADC values using various b-value sets were compared to reference-standard ADCIVIM values using all eight b-values. Intra-scan coefficient of variation (CV) of active tumour volumes was computed to compare the relative noise in ADC maps. ADC values for one pre-treatment DW-MRI scan of each of the 10 subjects were computed using b-value pairs from DW-MRI images synthesized for b-values of 0-2000 μs μm(-2) from the estimated IVIM parametric maps and corrupted by various Rician noise levels. The square root of mean of squared error percentage (RMSE) of the ADC value relative to the corresponding ADCIVIM for the tumour volume of the scan was computed. Monoexponential ADC values for the b-value sets of 250 and 1000; 250, 500 and 1000; 250, 650 and 1000; 250, 800 and 1000; and 250-1000 μs μm(-2) were not significantly different from ADCIVIM values (p > 0.05, paired t-test). Mean error in ADC values for these sets relative to ADCIVIM were within 3.5%. Intra-scan CVs for these sets were comparable to that for ADCIVIM. The monoexponential ADC values for other sets-0-1000; 50-1000; 100-1000; 500-1000; and 250 and 800 μs μm(-2) were significantly different from the ADCIVIM values. From Rician noise

  3. The influence of intraoperative pleural perfusion with matrine-cisplatin or cisplatin on stromal cell-derived factor-1 in non-small cell lung cancer patients with subclinical pleural metastasis.

    Science.gov (United States)

    Yang, Cheng-Liang; Liu, Shun-Shou; Ma, Ye-Gang; Liu, Yong-Yu; Xue, Yi-Xue; Huang, Bo

    2012-06-01

    The early diagnosis and treatment of non-small cell lung cancer (NSCLC) in patients with subclinical pleural metastasis is currently a challenge. In an effort to establish a method for the diagnosis and treatment of these patients, we conducted a single-blind study during which intraoperative pleural lavage cytology (PLC) was performed in 164 patients with NSCLC without obvious pleural effusion. Stromal cell-derived factor-1 (SDF-1) serum concentrations were analyzed using enzyme-linked immunoassay on day 1 prior to tumor resection and on day 7 postoperatively. Western blot analysis was used for the detection of CXCR4 protein expression in resected tumors. Intraoperative pleural perfusion chemotherapy, with either cisplatin or cisplatin plus matrine, was given to patients with positive PLC. A group of 30 patients with NSCLC that did not undergo intraoperative PLC were used as a control group. Of the 164 study patients, 41 (25%) patients had positive PLC. Serum SDF-1 concentrations were higher in PLC-positive patients compared with patients negative for PLC and control patients. Serum SDF-1 concentrations were also lower at postoperative day 7 in patients treated with cisplatin plus matrine compared with control patients and those perfused with cisplatin alone. A lower incidence of chemotherapy-related adverse events was observed in patients treated with cisplatin plus matrine versus those treated with cisplatin alone during the first postoperative month. Patients with positive PLC showed a higher CXCR4 protein expression than patients with negative PLC. Based on the results of this study, PLC combined with serum SDF-1 concentration measurements may be considered as an effective index to determine the risk of subclinical pleural metastasis in patients with lung cancer. In addition, cisplatin plus matrine was confirmed as an initial approach for pleural perfusion and was superior to cisplatin alone.

  4. The lungs

    International Nuclear Information System (INIS)

    Macey, D.J.; Marshall, R.

    1982-01-01

    Currently emission tomography of the lungs is only practical for perfusion images with sup(99m)Tc microaggregates and ventilation images with sup(81m)Kr. The following topics are touched on: the rotating gamma camera single photon ECT system, spatial resolution and linearity, resolution in phantom studies, area and volume studies, quantitation studies, with particular reference to the authors' experience of perfusion and ventilation in investigations of pulmonary embolism. (U.K.)

  5. Two independent anion transport systems in rabbit mandibular salivary glands

    DEFF Research Database (Denmark)

    Novak, I; Young, J A

    1986-01-01

    Cholinergically stimulated Cl and HCO3 transport in perfused rabbit mandibular glands has been studied with extracellular anion substitution and administration of transport inhibitors. In glands perfused with HCO3-free solutions, replacement of Cl with other anions supported secretion in the foll......Cholinergically stimulated Cl and HCO3 transport in perfused rabbit mandibular glands has been studied with extracellular anion substitution and administration of transport inhibitors. In glands perfused with HCO3-free solutions, replacement of Cl with other anions supported secretion...... stimulated secretion by about 30%, but when infused in addition to furosemide (0.1 mmol/l), it inhibited by about 20%. Amiloride (1.0 mmol/l) caused no inhibition. The results suggest that there are at least three distinct carriers in the rabbit mandibular gland. One is a furosemide-sensitive Na-coupled Cl...

  6. Characterizing potential heart agents with an isolated perfused heart system

    International Nuclear Information System (INIS)

    Pendleton, D.B.; Sands, H.; Gallagher, B.M.; Camin, L.L.

    1984-01-01

    The authors have used an isolated perfused heart system for characterizing potential myocardial perfusion radiopharamaceuticals. Rabbit or guinea pig (GP) hearts are removed and perfused through the aorta with a blood-free buffer. Heart rate and ventricular pressure are monitored as indices of viability. Tc-99m-MAA is 96-100% retained in these hearts, and Tc-99m human serum albumin shows less than 5% extraction. Tl-201 is 30-40% extracted. It is known that in-vivo, Tc-99m(dmpe)/sub 2/Cl/sub 2//sup +/ is taken up by rabbit heart but not by GP or human heart. Analogous results are obtained with the isolated perfused heart model, where the complex is extracted well by the isolated rabbit heart (24%) but not by the GP heart (<5%). Values are unchanged if human, rabbit or GP blood is mixed and co-injected with the complex. Tc-99m)dmpe)/sub 3//sup +/ is also taken up by rabbit but not by GP hearts in-vivo. However, isolated perfused hearts of both species extract this complex well (45-52%). Heart uptake is diminished to <7% if the complex is pre-equilibrated with human blood. GP blood produces a moderate inhibition (in GP hearts only) and rabbit blood has no effect. This suggests that a human or GP blood factor may have a significant effect on heart uptake of this complex. Tc-99m(CN-t-butyl)/sub 6//sup +/ is taken up well by both rabbit and GP hearts in-vivo, and is extracted 100% by both isolated perfused hearts. Heart retention remains high (73-75%) in the presence of human blood

  7. Lung radiopharmaceuticals

    International Nuclear Information System (INIS)

    Gonzalez, B.M.

    1994-01-01

    Indication or main clinical use of Lung radiopharmaceuticals is presented and clasification of radiopharmaceuticals as ventilation and perfusion studies. Perfusion radiopharmaceuticals, main controls for administration quality acceptance. Clearence after blood administration and main clinical applications. Ventilation radiopharmaceuticals, gases and aerosols, characteristics of a ideal radioaerosol, techniques of good inhalation procedure, clinical applications. Comparison of several radiopharmaceuticals reflering to retention time as 50% administered dose, percent administered dose at 6 hours post inhalation, blood activity at 30 and 60 minutes post inhalation, initial lung absorbed dose, cumulated activity.Kinetic description of two radiopharmaceuticals, 99mTcDTPA and 99mTc-PYP

  8. Rabbit analgesia.

    Science.gov (United States)

    Barter, Linda S

    2011-01-01

    With the increasing popularity of rabbits as household pets, the complexity of diagnostic and surgical procedures performed on rabbits is increasing, along with the frequency of routine surgical procedures. More practitioners are faced with the need to provide adequate analgesia for this species. Preemptive analgesia prior to planned surgical interventions may reduce nervous system changes in response to noxious input, as well as reduce postoperative pain levels and analgesic drug requirements. Concurrent administration of analgesic drugs to anesthetized rabbits undergoing painful procedures is warranted both pre- and intraoperatively as well as postoperatively. This article discusses the neuropharmacologic and pharmacologic aspects of pain in rabbits, and reviews current protocols for the use of analgesic drugs. Published by Elsevier Inc.

  9. Mouse lung adhesion assay for Bordetella pertussis

    Energy Technology Data Exchange (ETDEWEB)

    Burns, K A; Freer, J H [Department of Microbiology, Alexander Stone Building, Bearsden, Glasgow, Scotland

    1982-03-01

    The ability of Bordetella pertussis to adhere to cell surfaces has been demonstrated by adhesion to tissue culture cells and adhesion to chicken, hamster or rabbit trachea in organ culture. In this report a mouse lung assay for adhesion is described and the results obtained using two virulent strains of B. pertussis and their avirulent counterparts. These were a C modulation of one of the original virulent strains and a phase IV variant of the other virulent strain. Organisms were radiolabelled by adding 1 ..mu..Ci (37 K Bq) of (/sup 14/C)glutamic acid per 10 ml of culture medium before inoculation and incubation for 5 days. The lungs were washed by perfusion in situ with at least two volumes (1 ml) of sterile 1% (w/v) casamino acids. The percentage of the inoculated organisms retained in the lungs was determined, after removal of the lungs, by one of the following two methods: viable count or radioactive count. Results for both methods were expressed as the percentage of the inoculum retained in the lungs plus or minus one standard deviation.

  10. Mouse lung adhesion assay for Bordetella pertussis

    International Nuclear Information System (INIS)

    Burns, K.A.; Freer, J.H.

    1982-01-01

    The ability of Bordetella pertussis to adhere to cell surfaces has been demonstrated by adhesion to tissue culture cells and adhesion to chicken, hamster or rabbit trachea in organ culture. In this report a mouse lung assay for adhesion is described and the results obtained using two virulent strains of B. pertussis and their avirulent counterparts. These were a C modulation of one of the original virulent strains and a phase IV variant of the other virulent strain. Organisms were radiolabelled by adding 1 μCi (37 K Bq) of [ 14 C]glutamic acid per 10 ml of culture medium before inoculation and incubation for 5 days. The lungs were washed by perfusion in situ with at least two volumes (1 ml) of sterile 1% (w/v) casamino acids. The percentage of the inoculated organisms retained in the lungs was determined, after removal of the lungs, by one of the following two methods: viable count or radioactive count. Results for both methods were expressed as the percentage of the inoculum retained in the lungs plus or minus one standard deviation. (Auth.)

  11. 67Ga lung scan

    International Nuclear Information System (INIS)

    Niden, A.H.; Mishkin, F.S.; Khurana, M.M.L.; Pick, R.

    1977-01-01

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate 67 Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the 67 Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of 67 Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of 67 Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography

  12. Ventilation and perfusion display in a single image

    International Nuclear Information System (INIS)

    Lima, J.J.P. de; Botelho, M.F.R.; Pereira, A.M.S.; Rafael, J.A.S.; Pinto, A.J.; Marques, M.A.T.; Pereira, M.C.; Baganha, M.F.; Godinho, F.

    1991-01-01

    A new method of ventilation and perfusion display onto a single image is presented. From the data on regions of interest of the lungs, three-dimensional histograms are created, containing as parameters X and Y for the position of the pixels, Z for the perfusion and colour for local ventilation. The perfusion value is supplied by sets of curves having Z proportional to the local perfusion count rate. Ventilation modulates colour. Four perspective views of the histogram are simultaneously displayed to allow visualization of the entire organ. Information about the normal ranges for both ventilation and perfusion is also provided in the histograms. (orig.)

  13. The anionic basis of fluid secretion by the rabbit mandibular salivary gland

    DEFF Research Database (Denmark)

    Case, R M; Hunter, M; Novak, I

    1984-01-01

    The role played by anions in salivary secretion has been studied in experiments on the isolated, perfused mandibular gland of the rabbit, in which perfusate Cl- and/or HCO3- were replaced by other anions. Replacement of Cl- with Br- had no significant effect on salivary secretion rate, but replac......The role played by anions in salivary secretion has been studied in experiments on the isolated, perfused mandibular gland of the rabbit, in which perfusate Cl- and/or HCO3- were replaced by other anions. Replacement of Cl- with Br- had no significant effect on salivary secretion rate...

  14. Myocardial kinetics of hexakis (trimethylphosphite) technetium-99m (I) chloride (Tc-TMP) in rats, rabbits, dogs, cats and pigs

    International Nuclear Information System (INIS)

    Robbins, M.S.; Adams, M.D.

    1984-01-01

    Tc-TMP is readily taken up by the myocardium following intravenous administration to rats and dogs. In order to assess its potential as a myocardial perfusion imaging agent, the biodistribution and pharmacokinetics of Tc-TMP were evaluated following intravenous administration to rats, rabbits, dogs, cats and miniature pigs. Rats and rabbits were killed at several time points within a 24 hr period after treatment and tissue samples were assayed for radioactivity. In rats, estimated heart, liver and lung half-lives were 14.4 hr, 24 min and 40 min, respectively. In rabbits, 0.6% dose/g was observed in the heart at 30 min. Corresponding heart/blood, heart/liver and heart/lung ratios were 39.1, 10.7 and 5.1. Gamma camera imaging experiments were conducted in rabbits, dogs, cats and pigs over a 1-2 hr period following administration of Tc-TMP. All species exhibited myocardial uptake resulting in sustained visualization, although myocardial image intensity was less pronounced in the pig compared to the other species. Regions of interest were selected over the heart, liver and background, and time-activity curves were generated. Minimal myocardial clearance was observed in all species during the imaging time course. Hepatic activity was rapidly cleared in rabbits and pigs (t1/2 < 1.0 hr) resulting in improved heart/liver ratios at later time intervals. The myocardial accumulation and retention of Tc-TMP, demonstrated in five species, supports clinical evaluation as a myocardial imaging agent

  15. The predictive value of preoperative perfusion/ventilation scintigraphy, spirometry and x-ray of the lungs on postoperative pulmonary complications. A prospective study

    International Nuclear Information System (INIS)

    Fogh, J.; Wille-Joergensen, P.; Brynjolf, I.; Thorup, J.; Joergensen, T.; Bording, L.; Kjaergaard, J.

    1987-01-01

    Prospectively, 125 patients were examined with 99m Tc-perfusion scintigraphy, 89m Kr- or 127 Xe-ventilation scintigraphy and chest radiogram prior to major surgery. Postoperative therapy-demanding pulmonary complications occurred in 18% of the patients. A statistical association could be demonstrated between all the preoperative tests except ventilation scintigraphy and the frequency of complications. However, the predictive values of each of the tests, or even the combined results, were not significantly different from the frequency of complications among all the patients. It is concluded that the predictive values of perfusion-and ventilation scintigraphy, spirometry and radiogram of the chest are too low to be of any practical use. (author)

  16. Pulmonary ventilation and perfusion abnormalities and ventilation perfusion imbalance in children with pulmonary atresia or extreme tetralogy of Fallot

    Energy Technology Data Exchange (ETDEWEB)

    Dowdle, S.C.; Human, D.G.; Mann, M.D. (Univ. of Cape Town (South Africa))

    1990-08-01

    Xenon-133 lung ventilation and perfusion scans were done preoperatively after cardiac catheterization and cineangiocardiography in 19 children; 6 had pulmonary atresia with an intact ventricular septum and hypoplastic right ventricle, 4 pulmonary atresia with associated complex univentricular heart, and 9 extreme Tetralogy of Fallot. The four patients with discrepancies in the sizes of the left and right pulmonary arteries on angiography had marked asymmetry of pulmonary perfusion and ventilation-perfusion imbalance on scintigraphy. Similar degrees of asymmetry and imbalance were present in 6 of the 15 children with equal-size pulmonary vessels. Asymmetry of pulmonary perfusion and ventilation-perfusion imbalance were associated with a poor prognosis.

  17. Pulmonary ventilation and perfusion abnormalities and ventilation perfusion imbalance in children with pulmonary atresia or extreme tetralogy of Fallot

    International Nuclear Information System (INIS)

    Dowdle, S.C.; Human, D.G.; Mann, M.D.

    1990-01-01

    Xenon-133 lung ventilation and perfusion scans were done preoperatively after cardiac catheterization and cineangiocardiography in 19 children; 6 had pulmonary atresia with an intact ventricular septum and hypoplastic right ventricle, 4 pulmonary atresia with associated complex univentricular heart, and 9 extreme Tetralogy of Fallot. The four patients with discrepancies in the sizes of the left and right pulmonary arteries on angiography had marked asymmetry of pulmonary perfusion and ventilation-perfusion imbalance on scintigraphy. Similar degrees of asymmetry and imbalance were present in 6 of the 15 children with equal-size pulmonary vessels. Asymmetry of pulmonary perfusion and ventilation-perfusion imbalance were associated with a poor prognosis

  18. High lung volume increases stress failure in pulmonary capillaries

    Science.gov (United States)

    Fu, Z.; Costello, M. L.; Tsukimoto, K.; Prediletto, R.; Elliott, A. R.; Mathieu-Costello, O.; West, J. B.

    1992-01-01

    We previously showed that when pulmonary capillaries in anesthetized rabbits are exposed to a transmural pressure (Ptm) of approximately 40 mmHg, stress failure of the walls occurs with disruption of the capillary endothelium, alveolar epithelium, or sometimes all layers. The present study was designed to test whether stress failure occurred more frequently at high than at low lung volumes for the same Ptm. Lungs of anesthetized rabbits were inflated to a transpulmonary pressure of 20 cmH2O, perfused with autologous blood at 32.5 or 2.5 cmH2O Ptm, and fixed by intravascular perfusion. Samples were examined by both transmission and scanning electron microscopy. The results were compared with those of a previous study in which the lung was inflated to a transpulmonary pressure of 5 cmH2O. There was a large increase in the frequency of stress failure of the capillary walls at the higher lung volume. For example, at 32.5 cmH2O Ptm, the number of endothelial breaks per millimeter cell lining was 7.1 +/- 2.2 at the high lung volume compared with 0.7 +/- 0.4 at the low lung volume. The corresponding values for epithelium were 8.5 +/- 1.6 and 0.9 +/- 0.6. Both differences were significant (P less than 0.05). At 52.5 cmH2O Ptm, the results for endothelium were 20.7 +/- 7.6 (high volume) and 7.1 +/- 2.1 (low volume), and the corresponding results for epithelium were 32.8 +/- 11.9 and 11.4 +/- 3.7. At 32.5 cmH2O Ptm, the thickness of the blood-gas barrier was greater at the higher lung volume, consistent with the development of more interstitial edema. Ballooning of the epithelium caused by accumulation of edema fluid between the epithelial cell and its basement membrane was seen at 32.5 and 52.5 cmH2O Ptm. At high lung volume, the breaks tended to be narrower and fewer were oriented perpendicular to the axis of the pulmonary capillaries than at low lung volumes. Transmission and scanning electron microscopy measurements agreed well. Our findings provide a physiological

  19. Physiologic Evaluation of Ventilation Perfusion Mismatch and Respiratory Mechanics at Different Positive End-expiratory Pressure in Patients Undergoing Protective One-lung Ventilation.

    Science.gov (United States)

    Spadaro, Savino; Grasso, Salvatore; Karbing, Dan Stieper; Fogagnolo, Alberto; Contoli, Marco; Bollini, Giacomo; Ragazzi, Riccardo; Cinnella, Gilda; Verri, Marco; Cavallesco, Narciso Giorgio; Rees, Stephen Edward; Volta, Carlo Alberto

    2018-03-01

    Arterial oxygenation is often impaired during one-lung ventilation, due to both pulmonary shunt and atelectasis. The use of low tidal volume (VT) (5 ml/kg predicted body weight) in the context of a lung-protective approach exacerbates atelectasis. This study sought to determine the combined physiologic effects of positive end-expiratory pressure and low VT during one-lung ventilation. Data from 41 patients studied during general anesthesia for thoracic surgery were collected and analyzed. Shunt fraction, high V/Q and respiratory mechanics were measured at positive end-expiratory pressure 0 cm H2O during bilateral lung ventilation and one-lung ventilation and, subsequently, during one-lung ventilation at 5 or 10 cm H2O of positive end-expiratory pressure. Shunt fraction and high V/Q were measured using variation of inspired oxygen fraction and measurement of respiratory gas concentration and arterial blood gas. The level of positive end-expiratory pressure was applied in random order and maintained for 15 min before measurements. During one-lung ventilation, increasing positive end-expiratory pressure from 0 cm H2O to 5 cm H2O and 10 cm H2O resulted in a shunt fraction decrease of 5% (0 to 11) and 11% (5 to 16), respectively (P ventilation, high positive end-expiratory pressure levels improve pulmonary function without increasing high V/Q and reduce driving pressure.

  20. INFECTIOUS MYXOMATOSIS (SANARELLI) IN PREGNANT RABBITS

    Science.gov (United States)

    Sprunt, Douglas H.

    1932-01-01

    Pregnancy in rabbits alters the reactivity of the tissues to the virus of infectious myxomatosis. The livers of pregnant animals with the myxoma have a central acidophilic necrosis. Secondary lesions in the lungs are much more numerous and larger in the pregnant than in the non-gravid animals. In like manner the lesions in the spleen are more extensive in the pregnant rabbit. On the other hand the skin lesions of the pregnant animal are decreased in size. PMID:19870088

  1. [Lung scintigraphy].

    Science.gov (United States)

    Schümichen, Carl; Schmidt, Matthias; Krause, Thomas

    2018-06-01

    The S1 guideline for lung scintigraphy has been updated and extended in order to emphasize the advantages oft the method in detecting acute pulmonary embolism (PE) in the periphery oft the lung (subsegmental PE), in underlying subacute and chronic pulmonary disorders, as well as in detecting chronic LE (CTEPH). Method of choice is ventilation / perfusion (V/P) SPECT or V/P SPECT/CT with even higher specificity. Because of its high sensitivity, a threshold (V/P mismatch in at least one segment or two subsegments) is introduced to avoid overtreatment. In case of a change in the therapeutic approach (observation only instead of anticoaculation) the threshold can be omitted. New data concerning the clinical and therapeutical impact of subsegmental PE are included, the chapters open questions have been extented. Other indications for V/P SPECT (secondary diagnoses, abnormalities in pulmonary perfusion, prediction of postoperative lung function) are presented with new data. Schattauer GmbH.

  2. Value of chest X-ray combined with perfusion scan versus ventilation/perfusion scan in acute pulmonary embolism

    NARCIS (Netherlands)

    de Groot, M. R.; Turkstra, F.; van Marwijk Kooy, M.; Oostdijk, A. H.; van Beek, E. J.; Büller, H. R.

    2000-01-01

    The main purpose of ventilation scanning, as adjunct to perfusion lung scintigraphy, in acute pulmonary embolism is to allow for the classification of segmental perfusion defects as mismatched, which is generally accepted as proof for the presence of pulmonary embolism. We examined whether this

  3. Methodology for ventilation/perfusion SPECT

    DEFF Research Database (Denmark)

    Bajc, Marika; Neilly, Brian; Miniati, Massimo

    2010-01-01

    Ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) is the scintigraphic technique of choice for the diagnosis of pulmonary embolism and many other disorders that affect lung function. Data from recent ventilation studies show that the theoretic advantages of Technegas ov...

  4. Imaging of ventilation/perfusion ratio by gated regional spirometry

    International Nuclear Information System (INIS)

    Touya, J.J.; Jones, J.P.; Price, R.R.; Patton, J.A.; Erickson, J.J.; Rollo, F.D.

    1981-01-01

    Gated 133 Xe images of patients rebreathing into a closed system can provide images of the distribution of lung volumes, ventilation and specific ventilation. These have been shown to be accurate, precise, and do not require unusually sophisticated equipment or skills. A mathematical transformation is used to correct the images for lung movement, which does not alter the total number of counts in the image. Perfusion images are gated to remove motion blurring but not transformed. Ventilation/perfusion images showing the distribution of V/Q ratio are then generated from the individual ventilation and perfusion images. (author)

  5. Teratogenic effects of Khat (Catha edulis in New Zealand rabbit

    Directory of Open Access Journals (Sweden)

    Aref Saleh Abdul-Mughni

    2018-03-01

    Conclusion: Prenatal exposure of Khat in rabbit induces harmful effects in defferent visceral organs including liver, kidney, brain, spinal cord, spleen, intestine, heart and lung. [J Adv Vet Anim Res 2018; 5(1.000: 25-36

  6. Development of a Zealand white rabbit deposition model to study inhalation anthrax

    Energy Technology Data Exchange (ETDEWEB)

    Asgharian, Bahman; Price, Owen; Kabilan, Senthil; Jacob, Richard E.; Einstein, Daniel R.; Kuprat, Andrew P.; Corley, Richard A.

    2016-01-28

    Despite using rabbits in several inhalation exposure experiments to study diseases such as anthrax, there is a lack of understanding regarding deposition characteristics and fate of inhaled particles (bio-aerosols and viruses) in the respiratory tracts of rabbits. Such information allows dosimetric extrapolation to humans to inform human outcomes. The lung geometry of the New Zealand white rabbit (referred to simply as rabbits throughout the article) was constructed using recently acquired scanned images of the conducting airways of rabbits and available information on its acinar region. In addition, functional relationships were developed for the lung and breathing parameters of rabbits as a function of body weight. The lung geometry and breathing parameters were used to extend the existing deposition model for humans and several other species to rabbits. Evaluation of the deposition model for rabbits was made by comparing predictions with available measurements in the literature. Deposition predictions in the lungs of rabbits indicated smaller deposition fractions compared to those found in humans across various particle diameter ranges. The application of the deposition model for rabbits was demonstrated by extrapolating deposition predictions in rabbits to find equivalent human exposure concentrations assuming the same dose-response relationship between the two species. Human equivalent exposure concentration levels were found to be much smaller than those for rabbits.

  7. Development of a Zealand White Rabbit Deposition Model to Study Inhalation Anthrax

    Science.gov (United States)

    Asgharian, Bahman; Price, Owen; Kabilan, Senthil; Jacob, Richard E.; Einstein, Daniel R.; Kuprat, A.P.; Corley, Richard A.

    2016-01-01

    Despite using rabbits in several inhalation exposure experiments to study diseases such as anthrax, there is a lack of understanding regarding deposition characteristics and fate of inhaled particles (bio-aerosols and viruses) in the respiratory tracts of rabbits. Such information allows dosimetric extrapolation to humans to inform human outcomes. The lung geometry of the New Zealand white rabbit (referred to simply as rabbits throughout the article) was constructed using recently acquired scanned images of the conducting airways of rabbits and available information on its acinar region. In addition, functional relationships were developed for the lung and breathing parameters of rabbits as a function of body weight. The lung geometry and breathing parameters were used to extend the existing deposition model for humans and several other species to rabbits. Evaluation of the deposition model for rabbits was made by comparing predictions with available measurements in the literature. Deposition predictions in the lungs of rabbits indicated smaller deposition fractions compared to those found in humans across various particle diameter ranges. The application of the deposition model for rabbits was demonstrated by extrapolating deposition predictions in rabbits to find equivalent human exposure concentrations assuming the same dose-response relationship between the two species. Human equivalent exposure concentration levels were found to be much smaller than those for rabbits. PMID:26895308

  8. Incorporation of radioactive labelled cholin and palmitate into lung lecithin of rabbits treated with high doses of bromcarbamides, barbiturates and diazepam

    International Nuclear Information System (INIS)

    Wichert, P. von; Schmidt, C.; Pomraenke, K.; Wiegers, U.

    1977-01-01

    Severe intoxications with bromcarbamides often show respiratory complications. To answer the question if there is a direct effect of the drug on lung tissue the incorporation of radioactive labelled choline and palmitate into lung lecithin was investigated. The phospholipid metabolism is in close relation to the surfactant system of the lung. Secondly the influence of bromcarbamides was compared with other hypnotic drugs. There was a reduction of palmitate incorporation into lung lecithin down to 40%, whereas the incorporation of choline increases in bromcarbamide intoxication. The relation between palmitate and choline incorporation was 6.77 in the controls and it decreases to 2-3 in the bromcarbamide group. The total phospholipid content in the lung/g wet weight remained unchanged in all experiments. From this data it is concluded, that these drugs cause a reduction of fatty acid exchange of the lecithin molecules of the lung. This might lead to the production of non surface active lecithin. The clinical and the morphological aspects of severe bromcarbamide intoxication are consistent with a perturbation of the surfactant function. (orig./MG) [de

  9. Effects of ethanol and hyperosmotic perfusates on albumin synthesis and release

    International Nuclear Information System (INIS)

    Rothschild, M.A.; Oratz, M.; Schreiber, S.S.; Mongelli, J.

    1986-01-01

    Sucrose and ethanol inhibit albumin synthesis; sucrose via an osmotic mechanism and ethanol during its metabolism. The present study was undertaken to compare the effects of both of these agents on albumin synthesis and secretion, and to see if ethanol inhibition could be related to an osmotic effect. Male, fed rabbits served as liver donors in all studies. There were a total of 35 studies: 13 control; 10 ethanol (39 to 52 mM); 4 cycloheximide (0.5 mM), and 8 sucrose (1%). Plasma volume was measured with 125 I-albumin (human) and extracellular volume measured with either /sup 99m/Tc diethylenetriamine pentaacetic acid or [ 14 C]sucrose. During perfusion, rabbit albumin content in the perfusate was measured immunologically every 15 to 30 min for 225 min. Interstitial albumin efflux was measured by the rate of appearance in the perfusate of 125 I-albumin given to 10 other rabbits 3 days prior to hepatic removal and perfusion. During the initial 75 min of perfusion, 74% of the in vivo equilibrated exchangeable 125 I-albumin appeared in the perfusate, and during this period the rabbit albumin that entered the perfusate was taken to represent efflux from the interstitial volume plus synthesis. Rabbit albumin appearing in the perfusate during the later period of 150 min was taken to represent mainly synthesis and was used to calculate the amount of albumin that would be synthesized in 75 min. The difference between these two values would be hepatic interstitial albumin appearing in the perfusate

  10. /sup 67/Ga lung scan

    Energy Technology Data Exchange (ETDEWEB)

    Niden, A.H.; Mishkin, F.S.; Khurana, M.M.L.; Pick, R.

    1977-03-21

    Twenty-three patients with clinical signs of pulmonary embolic disease and lung infiltrates were studied to determine the value of gallium citrate /sup 67/Ga lung scan in differentiating embolic from inflammatory lung disease. In 11 patients without angiographically proved embolism, only seven had corresponding ventilation-perfusion defects compatible with inflammatory disease. In seven of these 11 patients, the /sup 67/Ga concentration indicated inflammatory disease. In the 12 patients with angiographically proved embolic disease, six had corresponding ventilation-perfusion defects compatible with inflammatory disease. None had an accumulation of /sup 67/Ga in the area of pulmonary infiltrate. Thus, ventilation-perfusion lung scans are of limited value when lung infiltrates are present. In contrast, the accumulation of /sup 67/Ga in the lung indicates an inflammatory process. Gallium imaging can help select those patients with lung infiltrates who need angiography.

  11. Acetate stimulates secretion in the rabbit mandibular gland

    DEFF Research Database (Denmark)

    Novak, I; Young, J A

    1989-01-01

    In isolated perfused rabbit mandibular glands undergoing stimulation with 0.8 microM acetylcholine, replacement of HCO3- with acetate (25 mM) increased fluid secretion by more than 100%. Other short-chain fatty acids, except for propionate, had a similar effect. We focused our further studies...

  12. Pharmacological activation of Kv11.1 in transgenic long QT-1 rabbits

    DEFF Research Database (Denmark)

    Bentzen, Bo Hjorth; Bahrke, Sophia; Wu, Kezhong

    2011-01-01

    Transgenic rabbits expressing pore mutants of K(V)7.1 display a long QT syndrome 1 (LQT1) phenotype. Recently, NS1643 has been described to increase I(Kr).We hypothesized that NS1643 would shorten the action potential duration (APD(90)) in LQT1 rabbits. Transgenic LQT1 rabbits were compared...... with littermate control (LMC) rabbits. In vivo electrocardiogram studies in sedated animals were performed at baseline and during 45 minutes of intravenous infusion of NS1643 or vehicle in a crossover design. Ex vivo monophasic action potentials were recorded from Langendorff-perfused hearts at baseline...

  13. Multiparametric imaging of patient and tumour heterogeneity in non-small-cell lung cancer: quantification of tumour hypoxia, metabolism and perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Elmpt, Wouter van; Zegers, Catharina M.L.; Reymen, Bart; Even, Aniek J.G.; Oellers, Michel; Troost, Esther G.C.; Lambin, Philippe [Maastricht University Medical Centre, Department of Radiation Oncology (MAASTRO), GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Dingemans, Anne-Marie C. [Maastricht University Medical Centre, Department of Pulmonology, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Wildberger, Joachim E.; Das, Marco [Maastricht University Medical Centre, Department of Radiology, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Mottaghy, Felix M. [Maastricht University Medical Centre, Department of Nuclear Medicine, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); University Hospital RWTH Aachen University, Department of Nuclear Medicine, Aachen (Germany)

    2016-02-15

    Multiple imaging techniques are nowadays available for clinical in-vivo visualization of tumour biology. FDG PET/CT identifies increased tumour metabolism, hypoxia PET visualizes tumour oxygenation and dynamic contrast-enhanced (DCE) CT characterizes vasculature and morphology. We explored the relationships among these biological features in patients with non-small-cell lung cancer (NSCLC) at both the patient level and the tumour subvolume level. A group of 14 NSCLC patients from two ongoing clinical trials (NCT01024829 and NCT01210378) were scanned using FDG PET/CT, HX4 PET/CT and DCE CT prior to chemoradiotherapy. Standardized uptake values (SUV) in the primary tumour were calculated for the FDG and hypoxia HX4 PET/CT scans. For hypoxia imaging, the hypoxic volume, fraction and tumour-to-blood ratio (TBR) were also defined. Blood flow and blood volume were obtained from DCE CT imaging. A tumour subvolume analysis was used to quantify the spatial overlap between subvolumes. At the patient level, negative correlations were observed between blood flow and the hypoxia parameters (TBR >1.2): hypoxic volume (-0.65, p = 0.014), hypoxic fraction (-0.60, p = 0.025) and TBR (-0.56, p = 0.042). At the tumour subvolume level, hypoxic and metabolically active subvolumes showed an overlap of 53 ± 36 %. Overlap between hypoxic sub-volumes and those with high blood flow and blood volume was smaller: 15 ± 17 % and 28 ± 28 %, respectively. Half of the patients showed a spatial mismatch (overlap <5 %) between increased blood flow and hypoxia. The biological imaging features defined in NSCLC tumours showed large interpatient and intratumour variability. There was overlap between hypoxic and metabolically active subvolumes in the majority of tumours, there was spatial mismatch between regions with high blood flow and those with increased hypoxia. (orig.)

  14. Ventilation perfusion radionuclide imaging in cryptogenic fibrosing alveolitis

    International Nuclear Information System (INIS)

    Bourke, S.J.; Hawkins, T.; Keavey, P.M.; Gascoigne, A.D.; Corris, P.A.

    1993-01-01

    There is increasing interest in ventilation perfusion (V/Q) imaging in cryptogenic fibrosing alveolitis because of the data these scans provide on the dynamic V/Q relationships in such patients undergoing single lung transplantation. We analysed the V/Q scans of 45 consecutive patients with advanced cryptogenic fibrosing alveolitis being considered for single lung transplantation. Scans were classified according to the presence, severity and degree of matching of defects in ventilation and perfusion images and the results were compared with the data obtained from lung function tests. Ventilation images showed defects in 13 (29%) and ''washout delay'' in 15 (33%) patients; 10 (22%) patients had asymmetric distribution of ventilation with one lung receiving >60% of total ventilation. Perfusion images showed normal perfusion in 8 (18%), mild defects in 18 (40%) and major defects in 19 (42%) patients. The distribution of perfusion between lungs was significantly asymmetric in 20 (45%) patients. V/Q images were matched in 15 (33%), mildly mismatched in 15 (33%) and severely mismatched in 15 (33%) patients, but the degree of V/Q mismatch did not show a relationship to KCO, PaO 2 or A-aO 2 gradient. The appearances were atypical of pulmonary embolism in eight patients. (Author)

  15. Dynamic contrast-enhanced perfusion area-detector CT assessed with various mathematical models: Its capability for therapeutic outcome prediction for non-small cell lung cancer patients with chemoradiotherapy as compared with that of FDG-PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Fujisawa, Yasuko [Toshiba Medical Systems Corporation, Otawara (Japan); Koyama, Hisanobu; Kishida, Yuji; Seki, Shinichiro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan)

    2017-01-15

    Purpose: To directly compare the capability of dynamic first-pass contrast-enhanced (CE-) perfusion area-detector CT (ADCT) and PET/CT for early prediction of treatment response, disease progression and overall survival of non-small cell carcinoma (NSCLC) patients treated with chemoradiotherapy. Materials and methods: Fifty-three consecutive Stage IIIB NSCLC patients who had undergone PET/CT, dynamic first-pass CE-perfusion ADCT, chemoradiotherapy, and follow-up examination were enrolled in this study. They were divided into two groups: 1) complete or partial response (CR + PR) and 2) stable or progressive disease (SD + PD). Pulmonary arterial and systemic arterial perfusions and total perfusion were assessed at targeted lesions with the dual-input maximum slope method, permeability surface and distribution volume with the Patlak plot method, tumor perfusion with the single-input maximum slope method, and SUV{sub max}, and results were averaged to determine final values for each patient. Next, step-wise regression analysis was used to determine which indices were the most useful for predicting therapeutic effect. Finally, overall survival of responders and non-responders assessed by using the indices that had a significant effect on prediction of therapeutic outcome was statistically compared. Results: The step-wise regression test showed that therapeutic effect (r{sup 2} = 0.63, p = 0.01) was significantly affected by the following three factors in order of magnitude of impact: systemic arterial perfusion, total perfusion, and SUV{sub max}. Mean overall survival showed a significant difference for total perfusion (p = 0.003) and systemic arterial perfusion (p = 0.04). Conclusion: Dynamic first-pass CE-perfusion ADCT as well as PET/CT are useful for treatment response prediction in NSCLC patients treated with chemoradiotherapy.

  16. Dynamic contrast-enhanced perfusion area-detector CT assessed with various mathematical models: Its capability for therapeutic outcome prediction for non-small cell lung cancer patients with chemoradiotherapy as compared with that of FDG-PET/CT

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Fujisawa, Yasuko; Koyama, Hisanobu; Kishida, Yuji; Seki, Shinichiro; Sugihara, Naoki; Yoshikawa, Takeshi

    2017-01-01

    Purpose: To directly compare the capability of dynamic first-pass contrast-enhanced (CE-) perfusion area-detector CT (ADCT) and PET/CT for early prediction of treatment response, disease progression and overall survival of non-small cell carcinoma (NSCLC) patients treated with chemoradiotherapy. Materials and methods: Fifty-three consecutive Stage IIIB NSCLC patients who had undergone PET/CT, dynamic first-pass CE-perfusion ADCT, chemoradiotherapy, and follow-up examination were enrolled in this study. They were divided into two groups: 1) complete or partial response (CR + PR) and 2) stable or progressive disease (SD + PD). Pulmonary arterial and systemic arterial perfusions and total perfusion were assessed at targeted lesions with the dual-input maximum slope method, permeability surface and distribution volume with the Patlak plot method, tumor perfusion with the single-input maximum slope method, and SUV max , and results were averaged to determine final values for each patient. Next, step-wise regression analysis was used to determine which indices were the most useful for predicting therapeutic effect. Finally, overall survival of responders and non-responders assessed by using the indices that had a significant effect on prediction of therapeutic outcome was statistically compared. Results: The step-wise regression test showed that therapeutic effect (r 2 = 0.63, p = 0.01) was significantly affected by the following three factors in order of magnitude of impact: systemic arterial perfusion, total perfusion, and SUV max . Mean overall survival showed a significant difference for total perfusion (p = 0.003) and systemic arterial perfusion (p = 0.04). Conclusion: Dynamic first-pass CE-perfusion ADCT as well as PET/CT are useful for treatment response prediction in NSCLC patients treated with chemoradiotherapy.

  17. Dynamic contrast-enhanced perfusion area-detector CT assessed with various mathematical models: Its capability for therapeutic outcome prediction for non-small cell lung cancer patients with chemoradiotherapy as compared with that of FDG-PET/CT.

    Science.gov (United States)

    Ohno, Yoshiharu; Fujisawa, Yasuko; Koyama, Hisanobu; Kishida, Yuji; Seki, Shinichiro; Sugihara, Naoki; Yoshikawa, Takeshi

    2017-01-01

    To directly compare the capability of dynamic first-pass contrast-enhanced (CE-) perfusion area-detector CT (ADCT) and PET/CT for early prediction of treatment response, disease progression and overall survival of non-small cell carcinoma (NSCLC) patients treated with chemoradiotherapy. Fifty-three consecutive Stage IIIB NSCLC patients who had undergone PET/CT, dynamic first-pass CE-perfusion ADCT, chemoradiotherapy, and follow-up examination were enrolled in this study. They were divided into two groups: 1) complete or partial response (CR+PR) and 2) stable or progressive disease (SD+PD). Pulmonary arterial and systemic arterial perfusions and total perfusion were assessed at targeted lesions with the dual-input maximum slope method, permeability surface and distribution volume with the Patlak plot method, tumor perfusion with the single-input maximum slope method, and SUV max , and results were averaged to determine final values for each patient. Next, step-wise regression analysis was used to determine which indices were the most useful for predicting therapeutic effect. Finally, overall survival of responders and non-responders assessed by using the indices that had a significant effect on prediction of therapeutic outcome was statistically compared. The step-wise regression test showed that therapeutic effect (r 2 =0.63, p=0.01) was significantly affected by the following three factors in order of magnitude of impact: systemic arterial perfusion, total perfusion, and SUV max . Mean overall survival showed a significant difference for total perfusion (p=0.003) and systemic arterial perfusion (p=0.04). Dynamic first-pass CE-perfusion ADCT as well as PET/CT are useful for treatment response prediction in NSCLC patients treated with chemoradiotherapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Pulmonary ventilation and perfusion imaging with dual-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F. [Klinikum Grosshadern, Department of Clinical Radiology, Ludwig Maximilians University, Muenchen (Germany); Klinikum Grosshadern, Institut fuer Klinische Radiologie, LMU Muenchen, Muenchen (Germany); Hoegl, Sandra; Fisahn, Juergen; Irlbeck, Michael [Klinikum Grosshadern, Department of Anesthesiology, Ludwig Maximilians University, Muenchen (Germany); Nikolaou, Konstantin; Maxien, Daniel; Reiser, Maximilian F.; Becker, Christoph R.; Johnson, Thorsten R.C. [Klinikum Grosshadern, Department of Clinical Radiology, Ludwig Maximilians University, Muenchen (Germany)

    2010-12-15

    To evaluate the feasibility of dual-energy CT (DECT) ventilation imaging in combination with DE perfusion mapping for a comprehensive assessment of ventilation, perfusion, morphology and structure of the pulmonary parenchyma. Two dual-energy CT acquisitions for xenon-enhanced ventilation and iodine-enhanced perfusion mapping were performed in patients under artificial respiration. Parenchymal xenon and iodine distribution were mapped and correlated with structural or vascular abnormalities. In all datasets, image quality was sufficient for a comprehensive image reading of the pulmonary CTA images, lung window images and pulmonary functional parameter maps and led to expedient results in each patient. With dual-source CT systems, DECT of the lung with iodine or xenon administration is technically feasible and makes it possible to depict the regional iodine or xenon distribution representing the local perfusion and ventilation. (orig.)

  19. The Rabbit Stream Cipher

    DEFF Research Database (Denmark)

    Boesgaard, Martin; Vesterager, Mette; Zenner, Erik

    2008-01-01

    The stream cipher Rabbit was first presented at FSE 2003, and no attacks against it have been published until now. With a measured encryption/decryption speed of 3.7 clock cycles per byte on a Pentium III processor, Rabbit does also provide very high performance. This paper gives a concise...... description of the Rabbit design and some of the cryptanalytic results available....

  20. Perfusion dyssynchrony analysis

    NARCIS (Netherlands)

    Chiribiri, A.; Villa, A.D.M.; Sammut, E.; Breeuwer, M.; Nagel, E.

    2015-01-01

    AIMS: We sought to describe perfusion dyssynchrony analysis specifically to exploit the high temporal resolution of stress perfusion CMR. This novel approach detects differences in the temporal distribution of the wash-in of contrast agent across the left ventricular wall. METHODS AND RESULTS:

  1. Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI-Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Fan Li [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China)], E-mail: fanli0930@163.com; Liu Shiyuan [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China); Sun Fei [GE Healthcare China (China)], E-mail: Fei.sun@med.ge.com; Xiao Xiangsheng [Department of Radiology, ChangZheng Hospital Affiliated to Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003 (China)], E-mail: lizhaobin79@163.com

    2009-04-15

    Objective: The aim of this study was to assess pulmonary parenchyma perfusion with flow-sensitive alternating inversion recovery (FAIR) in comparison with 3D dynamic contrast-enhanced (DCE) imaging in healthy volunteers and in patients with pulmonary embolism or lung cancer. Materials and methods: Sixteen healthy volunteers and 16 patients with pulmonary embolism (5 cases) or lung cancer (11 cases) were included in this study. Firstly, the optimized inversion time of FAIR (TI) was determined in 12 healthy volunteers. Then, FAIR imaging with the optimized TI was performed followed by DCE-MRI on the other 4 healthy volunteers and 16 patients. Tagging efficiency of lung and SNR of perfusion images were calculated with different TI values. In the comparison of FAIR with DCE-MRI, the homogeneity of FAIR and DCE-MRI perfusion was assessed. In the cases of perfusion abnormality, the contrast between normal lung and perfusion defects was quantified by calculating a normalized signal intensity ratio. Results: One thousand milliseconds was the optimal TI, which generated the highest lung tagging efficiency and second highest PBF SNR. In the volunteers, the signal intensity of perfusion images acquired with both FAIR and DCE-MRI was homogeneous. Wedged-shaped or triangle perfusion defects were visualized in five pulmonary embolisms and three lung cancer cases. There was no significant statistical difference in signal intensity ratio between FAIR and DCE-MRI (P > 0.05). In the rest of eight lung cancers, all the lesions showed low perfusion against the higher perfused pulmonary parenchyma in both FAIR and DCE-MRI. Conclusion: Pulmonary parenchyma perfusion imaging with FAIR was feasible, consistent and could obtain similar functional information to that from DCE-MRI.

  2. Assessment of pulmonary parenchyma perfusion with FAIR in comparison with DCE-MRI-Initial results

    International Nuclear Information System (INIS)

    Fan Li; Liu Shiyuan; Sun Fei; Xiao Xiangsheng

    2009-01-01

    Objective: The aim of this study was to assess pulmonary parenchyma perfusion with flow-sensitive alternating inversion recovery (FAIR) in comparison with 3D dynamic contrast-enhanced (DCE) imaging in healthy volunteers and in patients with pulmonary embolism or lung cancer. Materials and methods: Sixteen healthy volunteers and 16 patients with pulmonary embolism (5 cases) or lung cancer (11 cases) were included in this study. Firstly, the optimized inversion time of FAIR (TI) was determined in 12 healthy volunteers. Then, FAIR imaging with the optimized TI was performed followed by DCE-MRI on the other 4 healthy volunteers and 16 patients. Tagging efficiency of lung and SNR of perfusion images were calculated with different TI values. In the comparison of FAIR with DCE-MRI, the homogeneity of FAIR and DCE-MRI perfusion was assessed. In the cases of perfusion abnormality, the contrast between normal lung and perfusion defects was quantified by calculating a normalized signal intensity ratio. Results: One thousand milliseconds was the optimal TI, which generated the highest lung tagging efficiency and second highest PBF SNR. In the volunteers, the signal intensity of perfusion images acquired with both FAIR and DCE-MRI was homogeneous. Wedged-shaped or triangle perfusion defects were visualized in five pulmonary embolisms and three lung cancer cases. There was no significant statistical difference in signal intensity ratio between FAIR and DCE-MRI (P > 0.05). In the rest of eight lung cancers, all the lesions showed low perfusion against the higher perfused pulmonary parenchyma in both FAIR and DCE-MRI. Conclusion: Pulmonary parenchyma perfusion imaging with FAIR was feasible, consistent and could obtain similar functional information to that from DCE-MRI.

  3. Lung radiopharmaceuticals; Radioformacos pulmonares

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, B M [Instituto Nacional de Pediatroa (Mexico)

    1994-12-31

    Indication or main clinical use of Lung radiopharmaceuticals is presented and clasification of radiopharmaceuticals as ventilation and perfusion studies. Perfusion radiopharmaceuticals, main controls for administration quality acceptance. Clearence after blood administration and main clinical applications. Ventilation radiopharmaceuticals, gases and aerosols, characteristics of a ideal radioaerosol, techniques of good inhalation procedure, clinical applications. Comparison of several radiopharmaceuticals reflering to retention time as 50% administered dose, percent administered dose at 6 hours post inhalation, blood activity at 30 and 60 minutes post inhalation, initial lung absorbed dose, cumulated activity.Kinetic description of two radiopharmaceuticals, 99mTcDTPA and 99mTc-PYP.

  4. Initial plasma disappearance and tissue uptake of 131I-albumin in normal rabbits

    International Nuclear Information System (INIS)

    Bent-Hansen, L.

    1991-01-01

    The simultaneous plasma disappearance curves of 131I-albumin and 125I-fibrinogen were recorded in normal rabbits for 1 hr. Using fibrinogen as a plasma reference, the disappearance curves of albumin were shown to contain two separate phases of efflux: one fast from zero to 10 min. comprising 8% of the total tracer; and one slow appearing in the interval of 10 to 60 min. containing another 9% of the tracer. Total albumin escape was analyzed to yield an initial slope of 0.024 ± 0.004 min-1, corresponding to a wholebody unidirectional albumin clearance (Cl(0)) of 0.090 ± 0.009 ml(min*100 g)-1. The distribution of efflux was assessed by biopsy uptakes using the same tracers in spleen, kidney, heart, lung, liver, intestine, skin, muscle, and brain. The disappearance curve generally reflects a biphasic pattern of uptake in peripheral tissue, predominantly by muscle and lung. The rapid phase has contributions from the fast near equilibration of liver, and intestine and skin are significant codeterminants of the slow phase. Due to their low body masses highly perfused organs such as kidney, spleen, and heart have little influence on the plasma disappearance. In accordance, the Cl(0) determined for the wholebody was higher than initial clearances found in skin (0.053 ml(min*100 g)-1) and muscle (0.054 ml(min*100 g)-1), but much lower than those found in the highly perfused organs. The initial (unidirectional) rates of peripheral albumin transfer demonstrated, ranged from 10 to 30 times higher than estimates of lymphatic return, suggesting that transcapillary albumin exchange is mediated by high-rate bidirectional diffusion. The rapid decrease of net albumin exchange rates suggests a second, highly significant barrier located within the interstitial matrix, which restricts plasma escape and reduces plasma to lymph albumin transport

  5. Nuclear triiodothyronine receptors in rabbit heart

    International Nuclear Information System (INIS)

    Banerjee, S.K.; Ulrich, J.M.; Kaldor, G.J.

    1986-01-01

    Nuclear triiodothyronine receptors from rat liver have been characterized in detail by several investigators. However, little work has been done in this area using heart tissue. In this study they examined and characterized the triiodothyronine binding in rabbit hearts. Nuclei have been prepared from ventricular muscle cells of normal and thyrotoxic rabbits as well as from atrial muscle cells of normal rabbit. Hearts were perfused with a minimum essential medium containing collagenase and bovine serum albumin. Myocardial cells were isolated and then disrupted by sonication and washing with a Triton X-100 buffer solution. A discontinuous sucrose density gradient was then used to isolate the mycoardial nuclei. Radiolabelled triiodothyronine (T 3 ) binding to nuclei was examined using conditions described by established procedures. Scatchard analysis of the binding data yields maximum binding capacity (B/sub max/) of 0.17 +/- 0.2 pmol/mg DNA and apparent dissociation constant (K/sub d/) of 400 +/- 50 pM for normal heart T 3 -receptors. The apparent capacity for T 3 binding is approximately 40% greater in myocardial nuclei prepared from hearts of hyperthyroid rabbits. The binding capacity of atrial muscle nuclei is about fourfold lower than ventricular cell nuclei. The results suggest that binding capacity for T 3 -receptor in the atrium is considerably lower than that found in the ventricle

  6. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  7. Allergy to Rabbits. 1

    International Nuclear Information System (INIS)

    Price, J.A.; Longbottom, J.L.

    1986-01-01

    Investigations have been carried out into the presence of antibody light chains in rabbit allergenic extracts and the interference in RAST and crossed-radioimmunoelectrophoresis (XRIE) caused by antibodies directed against them. A ''non-specific'' uptake of radioactivity in XRIE has been demonstrated to be caused by direct cross-linking of the 125 I rabbit anti-human IgE by the sheep antibodies in the immunoprecipitate of rabbit light chains. Preincubation with normal rabbit serum blocked this direct uptake of the labelled antibody and enabled specific IgE uptake on the light chains to be demonstrated for rabbit allergic sera. Verification of the allergenicity of the light chains was obtained from a specific light chain RAST. Elution from a Sephacryl S-200 gel filtration column indicated a MW of approx. 50Kd and confirmation of the components as light chain dimers, not Fab fragments, was obtained by allotyping for loci present on heavy chains and light chains in the Fab region. Light chains were detected in urine from rabbits of all ages and in an extract of dust collected in a rabbit housing area. No background staining was observed in XRIE using rabbit antisera, either with rabbit allergic sera with specific IgE or with a human serum containing specific IgG antibodies to rabbit IgG. This latter serum also showed no evidence of uptake on all immunoprecipitates in systems using rabbit antisera, and did not give false positive RAST results when the labelled rabbit anti-human IgE contained unlabelled rabbit IgG. Those sera with specific IgE to light chains showed no uptake in XRIE using rabbit antisera, indicating that the IgE was possibly specific for epitopes revealed by the dissociation on the whole IgG molecule. (author)

  8. Assessment of the relationship between morphological emphysema phenotype and corresponding pulmonary perfusion pattern on a segmental level

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, Mark; Kauczor, Hans-Ulrich [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Ley, Sebastian [Chirurgische Klinik Dr. Rinecker, Department of Diagnostic and Interventional Radiology, Munich (Germany); Ludwig Maximilians University, Department of Clinical Radiology, Munich (Germany); Eberhardt, Ralf; Herth, Felix [Thoraxklinik University of Heidelberg, Department of Pneumology and Critical Care Medicine, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Menezes, Ravi [University of Toronto, Medical Imaging, Toronto (Canada); Sedlaczek, Oliver [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Member of German Lung Research Center DZL, Translational Lung Research Center TLRC-H, Heidelberg (Germany); Ley-Zaporozhan, Julia [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Ludwig Maximilians University, Department of Clinical Radiology, Munich (Germany)

    2015-01-15

    Distinct morphological emphysema phenotypes were assessed by CT to show characteristic perfusion defect patterns. Forty-one patients with severe emphysema (GOLD III/IV) underwent three-dimensional high resolution computed tomography (3D-HRCT) and contrast-enhanced magnetic resonance (MR) perfusion. 3D-HRCT data was visually analyzed for emphysema phenotyping and quantification by consensus of three experts in chest-radiology. The predominant phenotype per segment was categorized as normal, centrilobular, panlobular or paraseptal. Segmental lung perfusion was visually analyzed using six patterns of pulmonary perfusion (1-normal; 2-mild homogeneous reduction in perfusion; 3-heterogeneous perfusion without focal defects; 4-heterogeneous perfusion with focal defects; 5-heterogeneous absence of perfusion; 6-homogeneous absence of perfusion), with the extent of the defect given as a percentage. 730 segments were evaluated. CT categorized 566 (78 %) as centrilobular, 159 (22 %) as panlobular and 5 (<1 %) as paraseptal with no normals. Scores with regards to MR perfusion patterns were: 1-0; 2-0; 3-28 (4 %); 4-425 (58 %); 5-169 (23 %); 6-108 (15 %). The predominant perfusion pattern matched as follows: 70 % centrilobular emphysema - heterogeneous perfusion with focal defects (score 4); 42 % panlobular - homogeneous absence of perfusion (score 5); and 43 % panlobular - heterogeneous absence of perfusion (score 6). MR pulmonary perfusion patterns correlate with the CT phenotype at a segmental level in patients with severe emphysema. (orig.)

  9. Assessment of the relationship between morphological emphysema phenotype and corresponding pulmonary perfusion pattern on a segmental level

    International Nuclear Information System (INIS)

    Bryant, Mark; Kauczor, Hans-Ulrich; Ley, Sebastian; Eberhardt, Ralf; Herth, Felix; Menezes, Ravi; Sedlaczek, Oliver; Ley-Zaporozhan, Julia

    2015-01-01

    Distinct morphological emphysema phenotypes were assessed by CT to show characteristic perfusion defect patterns. Forty-one patients with severe emphysema (GOLD III/IV) underwent three-dimensional high resolution computed tomography (3D-HRCT) and contrast-enhanced magnetic resonance (MR) perfusion. 3D-HRCT data was visually analyzed for emphysema phenotyping and quantification by consensus of three experts in chest-radiology. The predominant phenotype per segment was categorized as normal, centrilobular, panlobular or paraseptal. Segmental lung perfusion was visually analyzed using six patterns of pulmonary perfusion (1-normal; 2-mild homogeneous reduction in perfusion; 3-heterogeneous perfusion without focal defects; 4-heterogeneous perfusion with focal defects; 5-heterogeneous absence of perfusion; 6-homogeneous absence of perfusion), with the extent of the defect given as a percentage. 730 segments were evaluated. CT categorized 566 (78 %) as centrilobular, 159 (22 %) as panlobular and 5 (<1 %) as paraseptal with no normals. Scores with regards to MR perfusion patterns were: 1-0; 2-0; 3-28 (4 %); 4-425 (58 %); 5-169 (23 %); 6-108 (15 %). The predominant perfusion pattern matched as follows: 70 % centrilobular emphysema - heterogeneous perfusion with focal defects (score 4); 42 % panlobular - homogeneous absence of perfusion (score 5); and 43 % panlobular - heterogeneous absence of perfusion (score 6). MR pulmonary perfusion patterns correlate with the CT phenotype at a segmental level in patients with severe emphysema. (orig.)

  10. Selective Heart, Brain and Body Perfusion in Open Aortic Arch Replacement.

    Science.gov (United States)

    Maier, Sven; Kari, Fabian; Rylski, Bartosz; Siepe, Matthias; Benk, Christoph; Beyersdorf, Friedhelm

    2016-09-01

    Open aortic arch replacement is a complex and challenging procedure, especially in post dissection aneurysms and in redo procedures after previous surgery of the ascending aorta or aortic root. We report our experience with the simultaneous selective perfusion of heart, brain, and remaining body to ensure optimal perfusion and to minimize perfusion-related risks during these procedures. We used a specially configured heart-lung machine with a centrifugal pump as arterial pump and an additional roller pump for the selective cerebral perfusion. Initial arterial cannulation is achieved via femoral artery or right axillary artery. After lower body circulatory arrest and selective antegrade cerebral perfusion for the distal arch anastomosis, we started selective lower body perfusion simultaneously to the selective antegrade cerebral perfusion and heart perfusion. Eighteen patients were successfully treated with this perfusion strategy from October 2012 to November 2015. No complications related to the heart-lung machine and the cannulation occurred during the procedures. Mean cardiopulmonary bypass time was 239 ± 33 minutes, the simultaneous selective perfusion of brain, heart, and remaining body lasted 55 ± 23 minutes. One patient suffered temporary neurological deficit that resolved completely during intensive care unit stay. No patient experienced a permanent neurological deficit or end-organ dysfunction. These high-risk procedures require a concept with a special setup of the heart-lung machine. Our perfusion strategy for aortic arch replacement ensures a selective perfusion of heart, brain, and lower body during this complex procedure and we observed excellent outcomes in this small series. This perfusion strategy is also applicable for redo procedures.

  11. Lung function

    International Nuclear Information System (INIS)

    Sorichter, S.

    2009-01-01

    The term lung function is often restricted to the assessment of volume time curves measured at the mouth. Spirometry includes the assessment of lung volumes which can be mobilised with the corresponding flow-volume curves. In addition, lung volumes that can not be mobilised, such as the residual volume, or only partially as FRC and TLC can be measured by body plethysmography combined with the determination of the airway resistance. Body plethysmography allows the correct positioning of forced breathing manoeuvres on the volume-axis, e.g. before and after pharmacotherapy. Adding the CO single breath transfer factor (T LCO ), which includes the measurement of the ventilated lung volume using He, enables a clear diagnosis of different obstructive, restrictive or mixed ventilatory defects with and without trapped air. Tests of reversibility and provocation, as well as the assessment of inspiratory mouth pressures (PI max , P 0.1 ) help to classify the underlying disorder and to clarify treatment strategies. For further information and to complete the diagnostic of disturbances of the ventilation, diffusion and/or perfusion (capillar-)arterial bloodgases at rest and under physical strain sometimes amended by ergospirometry are recommended. Ideally, lung function measurements are amended by radiological and nuclear medicine techniques. (orig.) [de

  12. Correlation of the perfusion scintigram with pulmonary functions in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Kou; Ashitaka, Tsuyoshi; Uchibori, Shigeyasu [Toho Univ., Tokyo (Japan). School of Medicine; Takano, Masaaki

    1992-11-01

    The authors carried out ventilation-perfusion scintigraphy and pulmonary function tests in 21 patients with chronic obstructive pulmonary disease. It was used [sup 99m]Tc-macroaggregate for perfusion scintigram and [sup 133]Xe gas for ventilation scintigram. It was added the radioactivities of rebreathing phase and made lung volume image using a computer. Regions of interest (ROIs) were derived from radioactivities in each image. ROIs on lung volume image included each whole lung and those on perfusion image included the areas which had relatively high radioactivity. The authors counted the area of ROIs on lung volume (L) and perfusion (P) images. Then it was used the ratio of perfusion to lung volume (P/L) as a parameter of pulmonary perfusion. P/L had the significant correlations with the vital capacity, the actual FFV[sub 1.0], arterial oxygen partial pressure, diffusing capacity, RV/TLC and peak flow rate. These results suggested that P/L was a useful parameter of pulmonary perfusion in chronic obstructive pulmonary disease. (author).

  13. Topographic distribution of pulmonary ventilation and perfusion in the horse

    International Nuclear Information System (INIS)

    Amis, T.C.; Pascoe, J.R.; Hornof, W.

    1984-01-01

    The regional distribution of ventilation to perfusion ratios (VA/Q) in the lungs of 8 healthy standing Thoroughbred geldings (4.4 +/- 1.5 years, 465.7 +/- 46.6 kg) was studied, using steady-state inhalation and IV infusion of the radioactive gas krypton-81m. The VA/Q was uniformly distributed within a vertical lung strip centered over the 9th rib on the right side. Ventilation per unit of alveolar volume (V/VA) assessed from the clearance of inhaled radioactive gas in 5 horses increased from 0.49 +/- 0.13 (arbitrary units) in nondependent lung zones to 1.45 +/- 0.16 in dependent lung zones. Seemingly, a vertical gradient of pulmonary ventilation exists in the horse that is matched by a similar gradient of perfusion

  14. Topographic distribution of pulmonary ventilation and perfusion in the horse

    Energy Technology Data Exchange (ETDEWEB)

    Amis, T.C.; Pascoe, J.R.; Hornof, W.

    1984-08-01

    The regional distribution of ventilation to perfusion ratios (VA/Q) in the lungs of 8 healthy standing Thoroughbred geldings (4.4 +/- 1.5 years, 465.7 +/- 46.6 kg) was studied, using steady-state inhalation and IV infusion of the radioactive gas krypton-81m. The VA/Q was uniformly distributed within a vertical lung strip centered over the 9th rib on the right side. Ventilation per unit of alveolar volume (V/VA) assessed from the clearance of inhaled radioactive gas in 5 horses increased from 0.49 +/- 0.13 (arbitrary units) in nondependent lung zones to 1.45 +/- 0.16 in dependent lung zones. Seemingly, a vertical gradient of pulmonary ventilation exists in the horse that is matched by a similar gradient of perfusion.

  15. The incorporation of SPECT functional lung imaging into inverse radiotherapy planning for non-small cell lung cancer

    International Nuclear Information System (INIS)

    Christian, Judith A.; Partridge, Mike; Nioutsikou, Elena; Cook, Gary; McNair, Helen A.; Cronin, Bernadette; Courbon, Frederic; Bedford, James L.; Brada, Michael

    2005-01-01

    Background and purpose: Patients with non-small cell lung cancer (NSCLC) often have inhomogeneous lung perfusion. Radiotherapy planning computed tomography (CT) scans have been accurately co-registered with lung perfusion single photon emission computed tomography (SPECT) scans to design radiotherapy treatments which limit dose to healthy 'perfused' lung. Patients and methods: Patients with localised NSCLC had CT and SPECT scans accurately co-registered in the planning system. The SPECT images were used to define a volume of perfused 'functioning' lung (FL). Inverse planning software was used to create 3D-conformal plans, the planning objective being either to minimise the dose to whole lungs (WL) or to minimise the dose to FL. Results: Four plans were created for each of six patients. The mean difference in volume between WL and FL was 1011.7 cm 3 (range 596.2-1581.1 cm 3 ). One patient with bilateral upper lobe perfusion deficits had a 16% reduction in FLV 2 (the percentage volume of functioning lung receiving ≥20 Gy). The remaining patients had inhomogeneous perfusion deficits such that inverse planning was not able to sufficiently optimise beam angles to avoid functioning lung. Conclusion: SPECT perfusion images can be accurately co-registered with radiotherapy planning CT scans and may be helpful in creating treatment plans for patients with large perfusion deficits

  16. Ventilation and ventilation/perfusion ratios

    International Nuclear Information System (INIS)

    Valind, S.O.

    1989-01-01

    The thesis is based on five different papers. The labelling of specific tracer compounds with positron emitting radionuclides enables a range of structural, physiological and biochemical parameters in the lung to be measured non-invasively, using positron emission tomography. This concept affords a unique opportunity for in vivo studies of different expressions of pulmonary pathophysiology at the regional level. The present thesis describes the application of positron emission tomography to the measurements of ventilation and ventilation/perfusion ratios using inert gas tracers, neon-19 and nitrogen-13 respectively. The validity of the methods applied was investigated with respect to the transport of inert gas tracers in the human lung. Both ventilation and the ventilation/perfusion ratio may be obtained with errors less than 10 % in the normal lung. In disease, however, errors may increase in those instances where the regional ventilation is very low or the intra-regional gas flow distribution is markedly nonuniform. A 2-3 fold increase in ventilation was demonstrated in normal nonsmoking subjects going from ventral to dorsal regions in the supine posture. These large regional differences could be well explained by the intrinsic elastic properties of lung tissue, considering the gravitational gradient in transpulmonary pressure. In asymptomatic smokers substantial regional ventilatroy abnormalities were found whilst the regional gas volume was similar in smokers and nonsmokers. The uncoupling between ventilation and gas volume probably reflects inflammatory changes in the airways. The regional differences in dV/dt/dQ/dt were relatively small and blood flow was largely matched to ventilation in the supine posture. However, small regions of lung with very low ventilation, unmatched by blood flow commonly exists in the most dependent parts of the lung in both smokers and nonsmokers. (29 illustrations, 7 tables, 113 references)

  17. Experimental corneal calcification, hydration and /sup 45/Ca uptake in rabbit corneas incubated in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Obenberger, J [Ceskoslovenska Akademie Ved, Prague. Oftalmologicka Laborator; Dobiasova, M; Babicky, A [Ceskoslovenska Akademie Ved, Prague. Isotopova Laborator Biologickych Ustavu

    1974-07-01

    Experimental corneal calcification could easily be produced by a combination of corneal injury (perfusion of the anterior chamber of the eye with a solution of potassium permanganate) amd dihydrotachysterol (DHT) treatment. Rabbit corneas with induced calcification as well as corneas of three additional groups of rabbits, i.e. those treated with permanganate or DHT only and control animals were incubated for two hours in a medium containing /sup 45/Ca. An increased uptake of /sup 45/Ca into the cornea was found in the group of rabbits receiving DHT only. Potassium cyanide added to the incubation medium did not affect corneal hydration nor the final activity of the incubated corneas. (auth)

  18. How to optimize the lung donor.

    Science.gov (United States)

    Sales, Gabriele; Costamagna, Andrea; Fanelli, Vito; Boffini, Massimo; Pugliese, Francesco; Mascia, Luciana; Brazzi, Luca

    2018-02-01

    Over the last two decades, lung transplantation emerged as the standard of care for patients with advanced and terminal lung disease. Despite the increment in lung transplantation rates, in 2016 the overall mortality while on waiting list in Italy reached 10%, whereas only 39% of the wait-list patients were successfully transplanted. A number of approaches, including protective ventilatory strategy, accurate management of fluid balance, and administration of a hormonal resuscitation therapy, have been reported to improve lung donor performance before organ retrieval. These approaches, in conjunction with the use of ex-vivo lung perfusion technique contributed to expand the lung donor pool, without affecting the harvest of other organs and the outcomes of lung recipients. However, the efficacy of issues related to the ex-vivo lung perfusion technique, such as the optimal ventilation strategy, the ischemia-reperfusion induced lung injury management, the prophylaxis of germs transmission from donor to recipient and the application of targeted pharmacologic therapies to treat specific donor lung injuries are still to be explored. The main objective of the present review is to summarize the "state-of-art" strategies to optimize the donor lungs and to present the actual role of ex-vivo lung perfusion in the process of lung transplant. Moreover, different approaches about the technique reported in literature and several issues that are under investigation to treat specific donor lung injury will be discussed.

  19. Regional ventilation/perfusion mismatch pattern in patient with Swyer James (MacLeod′s syndrome

    Directory of Open Access Journals (Sweden)

    Sait Sager

    2014-01-01

    Full Text Available Swyer James (McLeod′s syndrome (SJMS is an uncommon disease, which occurs as a result of childhood bronchiolitis obliterans. Patients may not be diagnosed until later in their life. A 46-year-old man underwent ventilation/perfusion scintigraphy for acute onset of dyspnea. The scan showed markedly diminished ventilation and perfusion unilaterally on the right middle and inferior lobes. However, mismatched ventilation-perfusion pattern was shown on the upper right lobe, which was consistent with pulmonary embolism. Unilaterally matched ventilation/perfusion defect can see in SJMS in lung scintigraphy; however, when pulmoner embolism may accompany, scintigraphy should be carefully examined.

  20. Dynamic (4D) CT perfusion offers simultaneous functional and anatomical insights into pulmonary embolism resolution

    Energy Technology Data Exchange (ETDEWEB)

    Mirsadraee, Saeed, E-mail: saeed.mirsadraee@ed.ac.uk [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); Reid, John H.; Connell, Martin [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); MacNee, William; Hirani, Nikhil [The Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom); Murchison, John T. [Department of Radiology, Royal Infirmary of Edinburgh, 51 Little France Crescent, Edinburgh EH16 4SA (United Kingdom); Beek, Edwin J. van [Clinical Research Imaging Centre, Queen' s Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh EH16 4TJ (United Kingdom)

    2016-10-15

    Objective: Resolution and long-term functional effects of pulmonary emboli are unpredictable. This study was carried out to assess persisting vascular bed perfusion abnormalities and resolution of arterial thrombus in patients with recent pulmonary embolism (PE). Methods and materials: 26 Patients were prospectively evaluated by dynamic (4D) contrast enhanced CT perfusion dynamic pulmonary CT perfusion. Intermittent volume imaging was performed every 1.5–1.7 s during breath-hold and perfusion values were calculated by maximum-slope technique. Thrombus load (modified Miller score; MMS) and ventricular diameter were determined. Perfusion maps were visually scored and correlated with residual endoluminal filling defects. Results: The mean initial thrombus load was 13.1 ± 4.6 MMS (3–16), and 1.2 ± 2.1 MMS (0–8) at follow up. From the 24 CTPs with diagnostic quality perfusion studies, normal perfusion was observed in 7 (29%), and mildly-severely abnormal in 17 (71%). In 15 patients with no residual thrombus on follow up CTPA, normal perfusion was observed in 6, and abnormal perfusion in 9. Perfusion was abnormal in all patients with residual thrombus on follow up CTPA. Pulmonary perfusion changes were classified as reduced (n = 4), delayed (systemic circulation pattern; n = 5), and absent (no-flow; n = 5). The right ventricle was dilated in 12/25 (48%) at presentation, and normal in all 26 follow up scans. Weak correlation was found between initial ventricular dilatation and perfusion abnormality at follow up (r = 0.15). Conclusions: Most patients had substantial perfusion abnormality at 3–6 months post PE. Abnormal perfusion patterns were frequently observed in patients and in regions with no corresponding evidence of residual thrombus on CTPA. Some defects exhibit delayed, presumed systemic, enhancement (which we have termed ‘stunned’ lung). CT perfusion provides combined anatomical and functional information about PE resolution.

  1. Recent lung imaging studies

    International Nuclear Information System (INIS)

    Taplin, G.V.; Chopra, S.K.

    1976-01-01

    Radionuclide lung imaging procedures have been available for 11 years but only the perfusion examination has been used extensively and mainly for the diagnosis of pulmonary embolism (P.E.). Its ability to reveal localized ischemia makes it a valuable test of regional lung function as well as a useful diagnostic aid in P.E. Although it had been recognized for several years that chronic obstructive pulmonary disease (COPD) can cause lung perfusion defects which may simulate pulmonary embolism, relatively little use has been made of either the radioxenon or the radioaerosol inhalation lung imaging procedures until the last few years as a means of distinguishing P.E. from COPD. In this review emphasis is placed on our recent experience with both of these inhalation procedures in comparison with pulmonary function tests and roentgenography for the early detection of COPD in population studies. Equal emphasis is given to simultaneous aerosol ventilation-perfusion (V/P) imaging for a functional diagnosis of P.E. Two new developments in regional lung diffusion imaging, performed after the inhalation of radioactive gases and/or rapidly absorbed radioaerosols are described. The experimental basis for their potential clinical application in pulmonary embolism detection is presented

  2. Pulmonary MR angiography and perfusion imaging—A review of methods and applications

    Energy Technology Data Exchange (ETDEWEB)

    Johns, Christopher S.; Swift, Andrew J.; Hughes, Paul J.C. [University of Sheffield (United Kingdom); Ohno, Yoshiharu [Division of Functional and Diagnostic Imaging Research, Department of Radiology, KobeUniversity Graduate School of Medicine, Kobe, Hyogo (Japan); Schiebler, Mark [UW-Madison School of Medicine and Public Health, Madison, WI (United States); Wild, Jim M., E-mail: j.m.wild@sheffield.ac.uk [University of Sheffield (United Kingdom)

    2017-01-15

    Highlights: • This article represents an overview of the methodology and clinical applications of pulmonary MRA and perfusion imaging. • Both contrast enhanced and non-contrast enhanced metholodology for MRA and perfusion are covered. • The current clinical uses and future directions of MRA and MR perfusion are discussed. - Abstract: The pulmonary vasculature and its role in perfusion and gas exchange is an important consideration in many conditions of the lung and heart. Currently the mainstay of imaging of the vasculature and perfusion of the lungs lies with CT and nuclear medicine perfusion scans, both of which require ionizing radiation exposure. Improvements in MRI techniques have increased the use of MRI in pulmonary vascular imaging. Here we review MRI methods for imaging the pulmonary vasculature and pulmonary perfusion, both using contrast enhanced and non-contrast enhanced methodology. In many centres pulmonary MR angiography and dynamic contrast enhanced perfusion MRI are now well established in the routine workflow of patients particularly with pulmonary hypertension and thromboembolic disease. However, these imaging modalities offer exciting new directions for future research and clinical use in other respiratory diseases where consideration of pulmonary perfusion and gas exchange can provide insight in to pathophysiology.

  3. Pulmonary MR angiography and perfusion imaging—A review of methods and applications

    International Nuclear Information System (INIS)

    Johns, Christopher S.; Swift, Andrew J.; Hughes, Paul J.C.; Ohno, Yoshiharu; Schiebler, Mark; Wild, Jim M.

    2017-01-01

    Highlights: • This article represents an overview of the methodology and clinical applications of pulmonary MRA and perfusion imaging. • Both contrast enhanced and non-contrast enhanced metholodology for MRA and perfusion are covered. • The current clinical uses and future directions of MRA and MR perfusion are discussed. - Abstract: The pulmonary vasculature and its role in perfusion and gas exchange is an important consideration in many conditions of the lung and heart. Currently the mainstay of imaging of the vasculature and perfusion of the lungs lies with CT and nuclear medicine perfusion scans, both of which require ionizing radiation exposure. Improvements in MRI techniques have increased the use of MRI in pulmonary vascular imaging. Here we review MRI methods for imaging the pulmonary vasculature and pulmonary perfusion, both using contrast enhanced and non-contrast enhanced methodology. In many centres pulmonary MR angiography and dynamic contrast enhanced perfusion MRI are now well established in the routine workflow of patients particularly with pulmonary hypertension and thromboembolic disease. However, these imaging modalities offer exciting new directions for future research and clinical use in other respiratory diseases where consideration of pulmonary perfusion and gas exchange can provide insight in to pathophysiology.

  4. Defibrotide reduces infarct size in a rabbit model of experimental myocardial ischaemia and reperfusion.

    Science.gov (United States)

    Thiemermann, C.; Thomas, G. R.; Vane, J. R.

    1989-01-01

    1. Defibrotide, a single-stranded polydeoxyribonucleotide obtained from bovine lungs, has significant anti-thrombotic, pro-fibrinolytic and prostacyclin-stimulating properties. 2. The present study was designed to evaluate the effects of defibrotide on infarct size and regional myocardial blood flow in a rabbit model of myocardial ischaemia and reperfusion. 3. Defibrotide (32 mg kg-1 bolus + 32 mg kg-1 h-1, i.v.) either with or without co-administration of indomethacin (5 mg kg-1 x 2, i.v.) was administered 5 min after occlusion of the left anterior-lateral coronary artery and continued during the 60 min occlusion and subsequent 3 h reperfusion periods. 4. Defibrotide significantly attenuated the ischaemia-induced ST-segment elevation and abolished the reperfusion-related changes (R-wave reduction and Q-wave development) in the electrocardiogram. In addition, defibrotide significantly improved myocardial blood flow in normal and in ischaemic, but not in infarcted sections of the heart. The improvement in blood flow in normal perfused myocardium, but not in the ischaemic area was prevented by indomethacin. 5. Although the area at risk was similar in all animal groups studied, defibrotide treatment resulted in a 51% reduction of infarct size. Indomethacin treatment abolished the reduction of infarct size seen with defibrotide alone. 6. The data demonstrate a considerable cardioprotective effect of defibrotide in the reperfused ischaemic rabbit myocardium. This effect may be related, at least in part, to a stimulation of endogenous prostaglandin formation. Other possible mechanisms are discussed. PMID:2758223

  5. Phase dependency of electrotonic spread of hyperpolarizing current pulses in the rabbit sinoatrial node

    NARCIS (Netherlands)

    Duivenvoorden, J. J.; Bouman, L. N.; Bukauskas, F. F.; Opthof, T.; Jongsma, H. J.

    1990-01-01

    Electrotonic current spread in the SA node of the rabbit was measured by means of hyperpolarizing current pulses (1 to 10 microA, 60 ms), which were injected intracellularly through a K(+)-perfused suction electrode. The pulses were applied at the beginning, middle or end of the diastolic

  6. Secretion of saliva by the rabbit mandibular gland in vitro: the role of anions

    DEFF Research Database (Denmark)

    Case, R M; Conigrave, A D; Hunter, M

    1981-01-01

    and ductal modification with a recently developed technique for isolation and perfusion of the rabbit mandibular gland. Neither of the major extracellular anions (Cl- or HCO-3) is essential for primary fluid secretion. HCO-3 can be removed altogether and replaced with Cl- without diminution in secretory rate...

  7. The role of buffer anions and protons in secretion by the rabbit mandibular salivary gland

    DEFF Research Database (Denmark)

    Case, R M; Conigrave, A D; Favaloro, E J

    1982-01-01

    1. The role of extracellular HCO3- and H+ in the formation of primary saliva and its subsequent modification by the glandular ducts has been investigated in the isolated perfused mandibular salivary gland of the rabbit. 2. Variation of extracellular HCO3- concentration between 12.5 and 50.0 mmol...

  8. RabbitMQ essentials

    CERN Document Server

    Dossot, David

    2014-01-01

    This book is a quick and concise introduction to RabbitMQ. Follow the unique case study of Clever Coney Media as they progressively discover how to fully utilize RabbitMQ, containing clever examples and detailed explanations.Whether you are someone who develops enterprise messaging products professionally or a hobbyist who is already familiar with open source Message Queuing software and you are looking for a new challenge, then this is the book for you. Although you should be familiar with Java, Ruby, and Python to get the most out of the examples, RabbitMQ Essentials will give you the push y

  9. Enhanced magnetic resonance pulmonary perfusion imaging in diagnosing pulmonary embolism: preliminary investigation

    International Nuclear Information System (INIS)

    Huang Xiaoyong; Du Jing; Zhang Zhaoqi; Guo Xi; Yan Zixu; Jiang Hong; Wang Wei

    2005-01-01

    Objective: This study was designed to investigate the sensitivity and specificity of magnetic resonance pulmonary perfusion imaging (MRPP) in diagnosing pulmonary embolism (PE) compared with enhanced magnetic resonance pulmonary angiography (MRPA) and pulmonary radionuclide perfusion imaging. Methods: Fourteen patients were definitely diagnosed as PE, whose ages were from 19 to 71 years old and mean 45.5 ± 19.8 years old. All patients under went MRPA and MRPP and 3 patients were examined again after thrombolytic treatment. Five patients underwent pulmonary radionuclide perfusion imaging. Setting ROI in top, middle, bottom of lung area and abnormal area respectively, we detected signal intensity and time-signal curve to obtain the transformation rate of signal (TROS) during perfusion peak value. Results: In 14 pulmonary embolism patients, MRPA found 62 branches of pulmonary artery obstruction. Fifty-five abnormal pulmonary perfusion zones were found by MRPP, and the above results were very alike. The coincidence was 88.71%. In 14 cases, MRPP could show 25 subsegments lesion below segments. In 5 patients who had both results Of MRPP and ECT at the same time. MRPP shows 33 perfusion defect zones and 37 segments were found by ECT, the sensitivity was 89.19%. After thrombolytic treatment, both the status of the affected pulmonary artery improved markedly and perfusion defect zones reduced obviously in 3 cases by MRPP and MRPA. TROS in normal perfusion zones perfusion defect zones and low perfusion zones had significant difference (t=22.882, P<0.01). Conclusion: Contrast enhanced MR pulmonary perfusion can show both perfusion defect zones and low perfusion zones in pulmonary embolism. Time-signal curve can show the period of maximum no perfusion zones in pulmonary artery embolism zones. And the amplitude of fluctuation is small with miminum TROS. MRPP has significant values especially in showing pulmonary artery embolism in segments and subsegments. Using both MRPP and

  10. Hepatic artery perfusion imaging

    International Nuclear Information System (INIS)

    Thrall, J.H.; Gyves, J.W.; Ziessman, H.A.; Ensminger, W.D.

    1985-01-01

    Organ and region-selective intra-arterial chemotherapy have been used for more than two decades to treat malignant neoplasms in the extremities, head and neck region, pelvis, liver, and other areas. Substantial evidence of improved response to regional chemotherapy now exists, but there are stringent requirements for successful application of the regional technique. First, the chemotherapeutic agent employed must have appropriate pharmacokinetic and pharmacodynamic properties. Second, the drug must be reliably delivered to the tumor-bearing area. This typically requires an arteriographic assessment of the vascular supply of the tumor, followed by placement of a therapeutic catheter and confirmation that the ''watershed'' perfusion distribution from the catheter truly encompasses the tumor. Optimal catheter placement also minimizes perfusion of nontarget organs. Radionuclide perfusion imaging with technetium 99m-labeled particles, either microspheres or macroaggregates of albumin, has become the method of choice for making these assessments. Catheter placement itself is considered by many to represent a type of ''therapeutic'' intervention. However, once the catheter is in the hepatic artery the radionuclide perfusion technique can be used to assess adjunctive pharmacologic maneuvers designed to further exploit the regional approach to chemotherapy. This chapter presents the technetium Tc 99m macroaggregated albumin method for assessing catheter placement and the pharmacokinetic rationale for regional chemotherapy, and discusses two promising avenues for further intervention

  11. Extremity perfusion for sarcoma

    NARCIS (Netherlands)

    Hoekstra, Harald Joan

    2008-01-01

    For more than 50 years, the technique of extremity perfusion has been explored in the limb salvage treatment of local, recurrent, and multifocal sarcomas. The "discovery" of tumor necrosis factor-or. in combination with melphalan was a real breakthrough in the treatment of primarily irresectable

  12. Isolated limb perfusion.

    Science.gov (United States)

    Gillespie, Rosalyn; Chantier, Nariane

    1994-12-08

    Growing concern over the rising incidence of malignant melanoma has brought about a need for information on this disorder and the treatment available. Isolated limb perfusion is a relatively new technique used in only a few hospitals. An increased knowledge base will lead to a better understanding of the nursing care required and to a more in-depth care plan.

  13. CT Perfusion Characteristics Identify Metastatic Sites in Liver

    Directory of Open Access Journals (Sweden)

    Yuan Wang

    2015-01-01

    Full Text Available Tissue perfusion plays a critical role in oncology because growth and migration of cancerous cells require proliferation of new blood vessels through the process of tumor angiogenesis. Computed tomography (CT perfusion is an emerging functional imaging modality that measures tissue perfusion through dynamic CT scanning following intravenous administration of contrast medium. This noninvasive technique provides a quantitative basis for assessing tumor angiogenesis. CT perfusion has been utilized on a variety of organs including lung, prostate, liver, and brain, with promising results in cancer diagnosis, disease prognostication, prediction, and treatment monitoring. In this paper, we focus on assessing the extent to which CT perfusion characteristics can be used to discriminate liver metastases from neuroendocrine tumors from normal liver tissues. The neuroendocrine liver metastases were analyzed by distributed parameter modeling to yield tissue blood flow (BF, blood volume (BV, mean transit time (MTT, permeability (PS, and hepatic arterial fraction (HAF, for tumor and normal liver. The result reveals the potential of CT perfusion as a tool for constructing biomarkers from features of the hepatic vasculature for guiding cancer detection, prognostication, and treatment selection.

  14. Biotransformation of hydralazine (HDZ) in monolayer cultures of rabbit hepatocytes

    International Nuclear Information System (INIS)

    McQueen, C.A.; Rosado, R.R.

    1990-01-01

    Adverse reactions to HDZ have been associated with the acetylator polymorphism; slow acetylators are more likely to develop HDZ-induced lupus erythematosus. In studying the role of this polymorphism in susceptibility to HDZ toxicity, the biotransformation of HDZ was investigated in rabbit hepatocytes. New Zealand white rabbits, like humans, are classified as rapid or slow acetylators. Heptocytes were isolated from rapid acetylator rabbits by collagenase perfusion. Monolayer cultures were initiated and exposed to 14 C-HDZ. Since HDZ is unstable at neutral pH, parallel incubations were done in the absence of cells. Metabolites in the media were determined by reverse phase HPLC. Phthalazine (P), phthalazinone (PZ), triazoloph-thalazine (TP), methyl TP (MTP) and 3-hydroxy MTP were identified. In the absence of cells, more TP was formed than MTP, probably resulting from reaction of HDZ with components in the medium. In the presence of cells, there was a three-fold increase in MTP, while the amount of TP was relatively constant. Only trace amounts of P, PZ 3-hydroxy MTP were detected. These data indicate that monolayer cultures of rapid acetylator rabbit hepatocytes were capable of metabolizing HDZ with acetylation playing a major role. These studies are being extended to cells from slow acetylator rabbits

  15. Effect of endobronchial valve therapy on pulmonary perfusion and ventilation distribution.

    Directory of Open Access Journals (Sweden)

    Carmen Pizarro

    Full Text Available Endoscopic lung volume reduction (ELVR is an emerging therapy for emphysematous COPD. However, any resulting changes in lung perfusion and ventilation remain undetermined. Here, we report ELVR-mediated adaptations in lung perfusion and ventilation, as investigated by means of pulmonary scintigraphy.In this observational study, we enrolled 26 patients (64.9 ± 9.4 yrs, 57.7% male with COPD heterogeneous emphysema undergoing ELVR with endobronchial valves (Zephyr, Pulmonx, Inc.. Mean baseline FEV1 and RV were 32.9% and 253.8% predicted, respectively. Lung scintigraphy was conducted prior to ELVR and eight weeks thereafter. Analyses of perfusion and ventilation shifts were performed and complemented by correlation analyses between paired zones.After ELVR, target zone perfusion showed a mean relative reduction of 43.32% (p<0.001, which was associated with a significant decrease in target zone ventilation (p<0.001. Perfusion of the contralateral untreated zone and of the contralateral total lung exhibited significant increases post-ELVR (p = 0.002 and p = 0.005, respectively; both correlated significantly with the corresponding target zone perfusion adaptations. Likewise, changes in target zone ventilation correlated significantly with ventilatory changes in the contralateral untreated zone and the total contralateral lung (Pearson's r: -0.42, p = 0.04 and Pearson's r: -0.42, p = 0.03, respectively. These effects were observed in case of clinical responsiveness to ELVR, as assessed by changes in the six-minute walk test distance.ELVR induces a relevant decrease in perfusion and ventilation of the treated zone with compensatory perfusional and ventilatory redistribution to the contralateral lung, primarily to the non-concordant, contralateral zone.

  16. Oxidative Damage and Mitochondrial Injuries Are Induced by Various Irrigation Pressures in Rabbit Models of Mild and Severe Hydronephrosis

    Science.gov (United States)

    Cao, Zhixiu; Yu, Weimin; Li, Wei; Cheng, Fan; Rao, Ting; Yao, Xiaobing; Zhang, Xiaobin; Larré, Stéphane

    2015-01-01

    Objective We aimed to study whether tolerance to irrigation pressure could be modified by evaluating the oxidative damage of obstructed kidneys based on rabbit models experiencing different degrees of hydronephrosis. Methods A total of 66 rabbits were randomly divided into two experimental groups and a control group. In the experimental groups, the rabbits underwent a surgical procedure inducing mild (group M, n=24) or severe (group S, n=24) hydronephrosis. In each experimental group, the rabbits were then randomly divided into 4 subgroups (M0-M3 and S0-S3) consisting of 6 rabbits each. Group 0 received no perfusion. Groups 1 through 3 were perfused with 20, 60 and 100 mmHg fluid, respectively. For the control group, after a sham operation was performed, the rabbits were divided into 4 subgroups and were perfused with fluid at 0, 20, 60 or 100 mmHg of pressure. Kidney injuries was evaluated by neutrophil gelatinase associated lipocalin (NGAL). Oxidative damage was assessed by analyzing superoxide dismutase (Mn-SOD) activity, malondialdehyde (MDA) levels, glutathione reductase (GR), catalase (CAT) and peroxide (H2O2) levels, mitochondrial injuries was assessed by mitochondrial membrane potential (MMP), the mitochondrial ultrastructure and tubular cell apoptosis. Results In the experimental groups, all results were similar for groups 0 and 1. In group 2, abnormalities were observed in the S group only, and the kidneys of rabbits in group 3 suffered oxidative damage and mitochondrial injuries with increased NGAL, decreased Mn-SOD, GR and CAT,increased MDA and H2O2, lower levels of MMP, mitochondrial vacuolization and an increased apoptotic index. Conclusion In rabbits, severely obstructed kidneys were more susceptible to oxidative damage and mitochondrial injury than mildly obstructed kidneys when subjected to higher degrees of kidney perfusion pressure. PMID:26090815

  17. Oxidative Damage and Mitochondrial Injuries Are Induced by Various Irrigation Pressures in Rabbit Models of Mild and Severe Hydronephrosis.

    Directory of Open Access Journals (Sweden)

    Zhixiu Cao

    Full Text Available We aimed to study whether tolerance to irrigation pressure could be modified by evaluating the oxidative damage of obstructed kidneys based on rabbit models experiencing different degrees of hydronephrosis.A total of 66 rabbits were randomly divided into two experimental groups and a control group. In the experimental groups, the rabbits underwent a surgical procedure inducing mild (group M, n=24 or severe (group S, n=24 hydronephrosis. In each experimental group, the rabbits were then randomly divided into 4 subgroups (M0-M3 and S0-S3 consisting of 6 rabbits each. Group 0 received no perfusion. Groups 1 through 3 were perfused with 20, 60 and 100 mmHg fluid, respectively. For the control group, after a sham operation was performed, the rabbits were divided into 4 subgroups and were perfused with fluid at 0, 20, 60 or 100 mmHg of pressure. Kidney injuries was evaluated by neutrophil gelatinase associated lipocalin (NGAL. Oxidative damage was assessed by analyzing superoxide dismutase (Mn-SOD activity, malondialdehyde (MDA levels, glutathione reductase (GR, catalase (CAT and peroxide (H2O2 levels, mitochondrial injuries was assessed by mitochondrial membrane potential (MMP, the mitochondrial ultrastructure and tubular cell apoptosis.In the experimental groups, all results were similar for groups 0 and 1. In group 2, abnormalities were observed in the S group only, and the kidneys of rabbits in group 3 suffered oxidative damage and mitochondrial injuries with increased NGAL, decreased Mn-SOD, GR and CAT,increased MDA and H2O2, lower levels of MMP, mitochondrial vacuolization and an increased apoptotic index.In rabbits, severely obstructed kidneys were more susceptible to oxidative damage and mitochondrial injury than mildly obstructed kidneys when subjected to higher degrees of kidney perfusion pressure.

  18. Assessment of smoking-induced impairment of pulmonary perfusion using three-dimensional SPECT images

    Energy Technology Data Exchange (ETDEWEB)

    Miyasaka, Takashi [Toho Univ., Tokyo (Japan). School of Medicine

    1997-09-01

    The effects of smoking on ventilation-perfusion lung scintigrams were investigated. The subjects comprised 40 healthy males (28 smokers and 12 nonsmokers) without a history of cardiopulmonary disease and with normal chest radiographs. After acquisition of planar images of ventilation lung scintigrams with 370 MBq of {sup 133}Xe gas, planar images and SPECT images of pulmonary perfusion flow were obtained using 185 MBq of {sup 99m}Tc-MAA. Planar imaging showed perfusion defects in only 5 smokers. In contrast, 16 subjects were found to have perfusion defects on SPECT images (p<0.05), indicating the usefulness of SPECT images in detecting minor vascular damage of the lung. Although perfusion defects were common in the smokers (p<0.05), their relationship to the BRINKMAN index was uncertain. The perfusion defects found in the smokers were nonsegmental and commonly involved the right upper lobe. Ventilation scans revealed only delayed washout of {sup 133}Xe in 4 smokers, suggesting that smoking-induced abnormal perfusion on SPECT appears earlier than impaired ventilation on scintigrams. (author)

  19. Changes in perfusion scintigraphy in the first days of heparin therapy in patients with acute pulmonary embolism

    NARCIS (Netherlands)

    de Groot, M. R.; Oostdijk, A. H.; Engelage, A. H.; van Marwijk Kooy, M.; Büller, H. R.

    2000-01-01

    Patients with suspected pulmonary embolism often receive heparin therapy for hours to days before ventilation/perfusion scintigraphy is completed. We assessed to what extent the lung scan classification and pulmonary vascular perfusion changed over a period of 2-4 days of full anticoagulant therapy.

  20. Prediction of postoperative lung function after pulmonary resection

    International Nuclear Information System (INIS)

    Yoshikawa, Koichi

    1988-01-01

    Lung scintigraphy and ordinary lung function test as well as split lung function test by using bronchospirometry was performed in 78 patients with primary lung cancer and clinical significance of ventilation and perfusion scintigraphy was evaluated. Results obtained from this study are as follows. 1) The ratio of right VC to total VC obtained by preoperative bronchospirometry was well correlated to the ratio of right lung count to the total lung count obtained by ventiration and/or perfusion scintigraphy (r = 0.84, r = 0.69). 2) Evaluation of the data obtained from the patients undergoing pneumonectomy indicated that the right and left VC obtained preoperatively by bronchospirometry have their clinical significance only in the form of left to right ratio not in the form their absolure value. 3) As to the reliability of predicting the residual vital capacity after pneumonectomy on the basis of left-to-right of lung scintigraphy, ventilation scintigraphy is more reliable than perfusion scintigraphy. 4) Irrespective of using ventilation scintigraphy or perfusion scintigraphy, Ali's formular showed high reliability in predicting the residual vital capacity as well as FEV 1.0 after lobectomy. 5) Reduction of the perfusion rate in the operated side of the lung is more marked than of the ventilation rate, resulting in a significant elevation of ventilation/perfusion ratio of the operated side of the lung. From the results descrived above, it can be said that lung ventilation and perfusion scintigraphy are very useful method to predict the residual lung function as well as the change of ventilation/perfusion ratio after pulmonary resection. (author)

  1. Correlation of semiquantitative analysis of the distribution of pulmonary perfusion with pulmonary function in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Uchida, Kou; Nakayama, Hiroyuki; Yamagami, Ikue; Takahashi, Hideki; Takano, Masaaki.

    1997-01-01

    We carried out ventilation-perfusion scintigraphy and pulmonary function tests in 56 patients with chronic obstructive pulmonary disease (COPD) and 19 healthy volunteers. We used 99m Tc-macroaggregated albumin for the perfusion scintigraphy and 133 Xe gas for the ventilation scintigraphy. The lung volume image was created by computerized summation of the radioactivity in the rebreathing phase. Regions of interest (ROIs) were set automatically on lung volume image, which included each whole lung, and on perfusion image, including areas with relatively high radioactivity, with cut-off levels of 50%, 70%, and 90%. The number of pixels in each ROI was used as an index of lung volume (L) or perfusion (P). Perfusion per unit of lung volume (P/L) was also used as an index of perfusion. P70 and P70/L showed the better correlations than the other parameters, including significant correlations with vital capacity, FEV 1.0 , peak flow rate, RV/TLC, diffusing capacity and arterial oxygen partial pressure. The significant difference in P70 and P70/L between patients with hypoxemia and those without hypoxemia suggested that P70 and P70/L are useful indicators of the severity of COPD. We conclude that semiquantified values of pulmonary perfusion scintigraphy are significantly correlated with pulmonary function and the severity of COPD. (author)

  2. The distribution of estrogen receptor in various organs of rabbit

    International Nuclear Information System (INIS)

    Son, H.Y.; In, J.W.; Min, B.S.

    1978-01-01

    For clinical application of radioreceptor assay, we studied preliminarily the distribution of estrogen receptor in various organs of rabbit by a dextran-charcoal method using 6,7- 3 H-es-tradiol. The results were expressed as binding index, which is the ratio of specific estradiol receptor binding radioactivity to total radioactivity. The materials consist of 5 female rabbits and 3 male rabbits. For female rabbits the binding index was highest in the uterine tissue. This binding index of the uterine tissue was 9.4 times that of the liver, 21.9 times that of the kidney, 24.6 times that of the brain, 28.1 times that of the lung and 65.7 times that of the muscle. For male rabbits the binding index was highest in the liver and decreased in the order of the kidney, the testis, the lung, the brain and the muscle. It is suggested that the estrogen receptor is not confined to any specific target organ but is widely distributed in the various organs, to a different degree. (author)

  3. The Distribution of Estrogen Receptor in Various Organs of Rabbit

    International Nuclear Information System (INIS)

    Son, Ho Young; In, Jae Whan; Min, Byong Sok

    1978-01-01

    For clinical application of radioreceptor assay, we studied preliminarily the distribution of estrogen receptor in various organs of rabbit by a dextran-charcoal method using 6, 7- 3 H-estradiol. The results were expressed as binding index, which is the ratio of specific estradiol receptor binding radioactivity to total radioactivity. The materials consist of 5 female rabbits and 3 male rabbits. The results were as follows: 1) Female rabbits. The binding index was highest in the uterine tissue. This binding index of the uterine tissue was 9.4 times that of the liver, 21.9 times that of the kidney, 24.6 times that of the brain, 28.1 times that of the lung and 65.7 times that of the muscle. 2) Male rabbits. The binding index was highest in the liver and decreased in the order of the kidney, the testis, the lung, the brain and the muscle. It is suggested that the estrogen receptor is not confined to any specific target organ but is widely distributed in the various organs, to a different degree.

  4. Lung inhalation scintigraphy with radioactive aerosols in several pulmonary diseases

    International Nuclear Information System (INIS)

    Martins, L.R.; Marioni Filho, H.; Romaldini, H.; Uehara, C.; Alonso, G.

    1983-01-01

    The pulmonary ventilation scintigraphy with 99m Tc diethylene-triamine-pentaacetate (99mTc-DTPA) delivered through a new nebulizer system when analyzed together with the classic lung perfusion scintigraphy with 99mTc-labeled albumin macroaggregates (99mTcMAA) is a very important diagnostic tool in several pulmonary diseases. Several aspects of the lung ventilation-perfusion scintigraphy are studied in 15 people with no lung disease, smokers and nonsmokers. The findings with the lung ventilation-perfusion scintigraphy are also discussed in 34 patients with several pulmonary diseases: lung cancer, chronic obstructive lung disease, policystic pulmonary disease, and pulmonary embolims. The authors concluded that the procedure is a valuable diagnostic tool in several pulmonary diseases, especially because good lung images are obtained, no side effects were detected, the technique is ease and low cost, and it brings new informations, not available with other diagnostic methods. (author)

  5. Perfusion based cell culture chips

    DEFF Research Database (Denmark)

    Heiskanen, Arto; Emnéus, Jenny; Dufva, Martin

    2010-01-01

    Performing cell culture in miniaturized perfusion chambers gives possibilities to experiment with cells under near in vivo like conditions. In contrast to traditional batch cultures, miniaturized perfusion systems provide precise control of medium composition, long term unattended cultures...... and tissue like structuring of the cultures. However, as this chapter illustrates, many issues remain to be identified regarding perfusion cell culture such as design, material choice and how to use these systems before they will be widespread amongst biomedical researchers....

  6. Dynamic Chest Image Analysis: Model-Based Perfusion Analysis in Dynamic Pulmonary Imaging

    Directory of Open Access Journals (Sweden)

    Kiuru Aaro

    2003-01-01

    Full Text Available The "Dynamic Chest Image Analysis" project aims to develop model-based computer analysis and visualization methods for showing focal and general abnormalities of lung ventilation and perfusion based on a sequence of digital chest fluoroscopy frames collected with the dynamic pulmonary imaging technique. We have proposed and evaluated a multiresolutional method with an explicit ventilation model for ventilation analysis. This paper presents a new model-based method for pulmonary perfusion analysis. According to perfusion properties, we first devise a novel mathematical function to form a perfusion model. A simple yet accurate approach is further introduced to extract cardiac systolic and diastolic phases from the heart, so that this cardiac information may be utilized to accelerate the perfusion analysis and improve its sensitivity in detecting pulmonary perfusion abnormalities. This makes perfusion analysis not only fast but also robust in computation; consequently, perfusion analysis becomes computationally feasible without using contrast media. Our clinical case studies with 52 patients show that this technique is effective for pulmonary embolism even without using contrast media, demonstrating consistent correlations with computed tomography (CT and nuclear medicine (NM studies. This fluoroscopical examination takes only about 2 seconds for perfusion study with only low radiation dose to patient, involving no preparation, no radioactive isotopes, and no contrast media.

  7. Single photon emission computed tomography study of human pulmonary perfusion: preliminary findings

    Energy Technology Data Exchange (ETDEWEB)

    Carratu, L; Sofia, M [Naples Univ. (Italy). Facolta di Medicina e Chirurgia; Salvatore, M; Muto, P; Ariemma, G [Istituto Nazionale per la Prevenzione, Lo Studio e La Cura dei Tumori Fondazione Pascale, Naples (Italy); Lopez-Majano, V [Cook County Hospital, Chicago, IL (USA). Nuclear Medicine Div.

    1984-02-01

    Single photon emission computed tomography (SPECT) was performed with /sup 99/Tcsup(m)-albumin macroaggregates to study human pulmonary perfusion in healthy subjects and patients with respiratory diseases such as chronic obstructive pulmonary disease (COPD) and lung neoplasms. The reconstructed SPECT data was displayed in coronal, transverse, sagittal plane sections and compared to conventional perfusion scans. The SPECT data gave more complicated anatomical information about the extent of damage and morphology of the pulmonary vascular bed. In healthy subjects and COPD patients, qualitative and quantitative assessment of pulmonary perfusion could be obtained from serial SPECT scans with respect to distribution and relative concentration of the injected radiopharmaceutical. Furthermore, SPECT of pulmonary perfusion has been useful in detecting the extent of damage to the pulmonary circulation. This is useful for the preoperative evaluation and staging of lung cancer.

  8. Lung emphysema induced by cigarette smoke: Studies in mice

    NARCIS (Netherlands)

    Eijl, Teunis Jan Ahasuerus van

    2006-01-01

    The experiments described in this thesis were designed to shed some more light on the mechanisms underlying cigarette smoke-induced lung emphysema. We used elastase instillation to induce lung emphysema, and subsequently perfused the lungs ex-vivo with buffer at a range of flows to measure changes

  9. Regional lung function evaluation with nitrogen-13

    Energy Technology Data Exchange (ETDEWEB)

    Ahluwalia, B; Brownell, G L; Hales, C; Kazemi, H

    1981-10-01

    Regional ventilation and perfusion studies are routinely performed with molecular nitrogen-13 (a short-lived positron emitter), a multicrystal positron camera, and a computer. These studies have the advantage of viewing with equal sensitivity all sections of the lung simultaneously. Nitrogen-13 is less soluble than xenon in blood and therefore allows more accurate ventilation imaging. The short half-life of the radiopharmaceutical allows simultaneous ventilation and perfusion scintigraphy of the lung. Unlike other imaging techniques in which the residual radioactivity persists in the lung for hours, nitrogen-13 is rapidly cleared allowing repetitive imaging. Ventilation and perfusion studies are part of the routine preoperative evaluation for lung cancer resection or for bullectomy in patients with chronic obstructive pulmonary disease and for assessment of pulmonary emboli in the presence of chronic obstructive disease.

  10. Radiospirometry and perfusion scintigraphy in cases of limited pulmonary fibrosis

    International Nuclear Information System (INIS)

    Tarkowska, A.; Smajkiewicz, L.; Szarewicz-Adamczyk, W.; Zaorska-Rajca, J.; Woytowicz, A.; Patyra, S.

    1981-01-01

    In 60 cases of limited pulmonary fibrosis radiospirometric investigation was performed using 133 Xe and a four-channel set. Perfusion scintigraphy was done as well after administration of labelled molecules. In all patients abnormalities were found in the results of both isotope methods suggesting presence of disturbances in the regional pulmonary functions. These disturbances included impairment of perfusion as well as ventilation, with evidence of obturation, increased volume of residual air, and decreased vital and total capasity of the lungs. These abnormalities occurred exclusively or most intensively in the areas corresponding to the location of the anatomical change, and in a considerable proportion of cases they were more extensive than the radiological changes. In about 40% of the patients in the contralateral lung diffuse changes of perfusion and ventilation were present, although much less intense, suggesting concomitant chronic obturative disease. The authors think that perfusion scintigraphy and radiospirometry owing to their value as a method of assessing pulmonary function are useful in cases of pulmonary fibrosis for establishing treatment methods and for evaluating disability to work. (author)

  11. Thermoablation of Malignant Kidney Tumors Using Magnetic Nanoparticles: An In Vivo Feasibility Study in a Rabbit Model

    International Nuclear Information System (INIS)

    Bruners, Philipp; Braunschweig, Till; Hodenius, Michael; Pietsch, Hubertus; Penzkofer, Tobias; Baumann, Martin; Guenther, Rolf W.; Schmitz-Rode, Thomas; Mahnken, Andreas H.

    2010-01-01

    The objective of this study was to assess the technical feasibility of CT-guided magnetic thermoablation for the treatment of malignant kidney tumors in a VX2 tumor rabbit model. VX2 tumors were implanted into the kidneys of five rabbits and allowed to grow for 2 weeks. After preinterventional CT perfusion imaging, CT-guided injection of superparamagnetic iron oxide particles (300 μl) was performed, followed by exposure of the animals to an alternating electromagnetic field for 15 min (∼0.32 kA/m). Then animals underwent CT perfusion imaging again. Afterward, animals were sacrificed and kidneys were dissected for macroscopic and histological evaluation. Changes in perfusion before and after exposure to the alternating magnetic field were analyzed. In one animal no tumor growth could be detected so the animal was used for optimization of the ablation procedure including injection technique and peri-interventional cross-sectional imaging (CT, MRI). After image-guided intratumoral injection of ferrofluids, the depiction of nanoparticle distribution by CT correlated well with macroscopic evaluation of the dissected kidneys. MRI was limited due to severe susceptibility artefacts. Postinterventional CT perfusion imaging revealed a perfusion deficiency around the ferrofluid deposits. Histological workup showed different zones of thermal damage adjacent to the ferrofluid deposits. In conclusion, CT-guided magnetic thermoablation of malignant kidney tumors is technically feasible in an animal model and results in a perfusion deficiency indicating tumor necrosis as depicted by CT perfusion imaging and shown in histological evaluation.

  12. The value of lung scintigraphy in the diagnosis of pulmonary embolism

    NARCIS (Netherlands)

    van Beek, E. J.; Tiel-van Buul, M. M.; Büller, H. R.; van Royen, E. A.; ten Cate, J. W.

    1993-01-01

    The role of lung scintigraphy in the diagnostic management of patients with clinically suspected pulmonary embolism is reviewed. Evidence is provided that a normal perfusion scan excludes clinically relevant pulmonary embolism, and that a high probability lung scan, defined as a segmental perfusion

  13. Gammagraphy of cerebral perfusion

    International Nuclear Information System (INIS)

    Vazquez, Silvia

    2003-01-01

    Important aspects of the gammagraphy of cerebral perfusion and the diverse clinical applications in the neurological diseases are comment in this article. We focus in the usefulness of the photon emission cerebral tomography (SPECT) and its capacity to cross the hemato encephalic barrier through the use of radiopharmacons like 99 mTc-H M-PAO and 99mTc-EDC, thus managing to offer functional data on the captantes neurons of the radiopharmacon. The clinical applications of SPECT are studied; cerebrovascular disease, transient ischemic attacks, dementias, Alzheimer disease, as well as other neurological diseases are referred. (The author)

  14. Effects of in vitro cultivated Calculus Bovis compound on pulmonary lesions in rabbits with schistosomiasis.

    Science.gov (United States)

    Li, Tao; Yang, Zhen; Cai, Hong-Jiao; Song, Li-Wei; Lu, Ke-Yu; Zhou, Zheng; Wu, Zai-De

    2010-02-14

    To explore the interventional effects and mechanism of in vitro cultivated Calculus Bovis compound preparation (ICCBco) on pulmonary lesions in portal hypertensive rabbits with schistosomiasis. The experimental group included 20 portal hypertensive rabbits with schistosomiasis treated by ICCBco. The control group included 20 portal hypertensive rabbits with schistosomiasis treated by praziquantel. The morphological changes of the pulmonary tissues were observed under light and electron microscopy. The expression of fibronectin (FN) and laminin (LN) in the lung tissues was analyzed by immunohistochemistry. Under light microscope, the alveolar exudation in the lung tissue was more frequently observed in the control group, while the alveolar space was fairly dry in the lung tissue of ICCBco group. Under electron microscope, more alveolar exudation in the lung tissue, and more macrophages, alveolar angiotelectasis and the blurred three-tier structure of alveolar-capillary barrier could be seen in the control group. In ICCBco group, fibers within the alveolar interspace slightly increased in some lung regions, and the structure of type I epithelium, basement membrane and endodermis was complete, and no obvious exudation from the alveolar space, and novascular congestion could be observed. There was a positive or strong positive expression of FN and LN in the lung tissue of the control group, while there was a negative or weak positive expression of FN and LN in ICCBco group. ICCBco can effectively prevent pulmonary complications in portal hypertensive rabbits with schistosomiasis by means of improving lung microcirculation and lowering the content of extracellular matrix.

  15. Hepatitis E Virus in Farmed Rabbits, Wild Rabbits and Petting Farm Rabbits in the Netherlands

    NARCIS (Netherlands)

    Burt, S.A.; Veltman, Jorg; Hakze-van der Honing, Renate; Schmitt, Heike; van der Poel, Wim H.M.

    2016-01-01

    Rabbits have been suggested as a zoonotic source of Hepatitis E virus. Phylogenetic analysis of HEV isolates from farmed, wild and pet rabbits in the Netherlands (23, 0, and 60 % respectively) showed them to be grouped amongst published rabbit HEV sequences and distinct from most human isolates.

  16. Hepatitis E Virus in Farmed Rabbits, Wild Rabbits and Petting Farm Rabbits in the Netherlands

    NARCIS (Netherlands)

    Burt, Sara A.; Veltman, Jorg; Hakze-van der Honing, Renate; Schmitt, Heike; Poel, van der Wim H.M.

    2016-01-01

    Rabbits have been suggested as a zoonotic source of Hepatitis E virus. Phylogenetic analysis of HEV isolates from farmed, wild and pet rabbits in the Netherlands (23, 0, and 60 % respectively) showed them to be grouped amongst published rabbit HEV sequences and distinct from most human isolates.

  17. MRI of the lung

    Energy Technology Data Exchange (ETDEWEB)

    Kauczor, Hans-Ulrich (ed.) [University Clinic Heidelberg (Germany). Diagnostic and Interventional Radiology

    2009-07-01

    For a long time, only chest X-ray and CT were used to image lung structure, while nuclear medicine was employed to assess lung function. During the past decade significant developments have been achieved in the field of magnetic resonance imaging (MRI), enabling MRI to enter the clinical arena of chest imaging. Standard protocols can now be implemented on up-to-date scanners, allowing MRI to be used as a first-line imaging modality for various lung diseases, including cystic fibrosis, pulmonary hypertension and even lung cancer. The diagnostic benefits stem from the ability of MRI to visualize changes in lung structure while simultaneously imaging different aspects of lung function, such as perfusion, respiratory motion, ventilation and gas exchange. On this basis, novel quantitative surrogates for lung function can be obtained. This book provides a comprehensive overview of how to use MRI for imaging of lung disease. Special emphasis is placed on benign diseases requiring regular monitoring, given that it is patients with these diseases who derive the greatest benefit from the avoidance of ionizing radiation. (orig.)

  18. Idiopathic pulmonary fibrosis. A rare cause of scintigraphic ventilation-perfusion mismatch

    International Nuclear Information System (INIS)

    Pochis, W.T.; Krasnow, A.Z.; Collier, B.D.; Mewissen, M.W.; Almagro, U.A.; Hellman, R.S.; Isitman, A.T.

    1990-01-01

    A case of idiopathic pulmonary fibrosis with multiple areas of mismatch on ventilation-perfusion lung imaging in the absence of pulmonary embolism is presented. Idiopathic pulmonary fibrosis is one of the few nonembolic diseases producing a pulmonary ventilation-perfusion mismatch. In this condition, chest radiographs may not detect the full extent of disease, and xenon-133 ventilation imaging may be relatively insensitive to morbid changes in small airways. Thus, when examining patients with idiopathic pulmonary fibrosis, one should be aware that abnormal perfusion imaging patterns without matching ventilation abnormalities are not always due to embolism. In this setting, contrast pulmonary angiography is often needed for accurate differential diagnosis

  19. Idiopathic pulmonary fibrosis. A rare cause of scintigraphic ventilation-perfusion mismatch

    Energy Technology Data Exchange (ETDEWEB)

    Pochis, W.T.; Krasnow, A.Z.; Collier, B.D.; Mewissen, M.W.; Almagro, U.A.; Hellman, R.S.; Isitman, A.T. (Medical College of Wisconsin, Milwaukee (USA))

    1990-05-01

    A case of idiopathic pulmonary fibrosis with multiple areas of mismatch on ventilation-perfusion lung imaging in the absence of pulmonary embolism is presented. Idiopathic pulmonary fibrosis is one of the few nonembolic diseases producing a pulmonary ventilation-perfusion mismatch. In this condition, chest radiographs may not detect the full extent of disease, and xenon-133 ventilation imaging may be relatively insensitive to morbid changes in small airways. Thus, when examining patients with idiopathic pulmonary fibrosis, one should be aware that abnormal perfusion imaging patterns without matching ventilation abnormalities are not always due to embolism. In this setting, contrast pulmonary angiography is often needed for accurate differential diagnosis.

  20. Prediction of postoperative pulmonary function following thoracic operations. Value of ventilation-perfusion scanning

    International Nuclear Information System (INIS)

    Bria, W.F.; Kanarek, D.J.; Kazemi, H.

    1983-01-01

    Surgical resection of lung cancer is frequently required in patients with severely impaired lung function resulting from chronic obstructive pulmonary disease. Twenty patients with obstructive lung disease and cancer (mean preoperative forced expiratory volume in 1 second [FEV1] . 1.73 L) were studied preoperatively and postoperatively by spirometry and radionuclide perfusion, single-breath ventilation, and washout techniques to test the ability of these methods to predict preoperatively the partial loss of lung function by the resection. Postoperative FEV1 and forced vital capacity (FVC) were accurately predicted by the formula: postoperative FEV1 (or FVC) . preoperative FEV1 X percent function of regions of lung not to be resected (r . 0.88 and 0.95, respectively). Ventilation and perfusion scans are equally effective in prediction. Washout data add to the sophistication of the method by permitting the qualitative evaluation of ventilation during tidal breathing. Criteria for patients requiring the study are suggested

  1. Follow-up of pulmonary perfusion recovery after embolism

    International Nuclear Information System (INIS)

    Palla, A.; Donnamaria, V.; Petruzzelli, S.; Giuntini, C.

    1986-01-01

    Blood flow recovery in a group of 69 patients with pulmonary embolism was followed by serial lung scans over a six month period. Each patient underwent perfusion lung scan at diagnosis then 7, 30 and 180 days later; i.v. heparin was systematically administered for one week after diagnosis, followed by oral warfarin for six months. Blood flow impairment was evaluated by assessing the total number of unperfused lung segments (ULS), as calculated on both lateral views at each scan. The number of ULS was significantly reduced at each interval (P<0.001), ranging from 8.4±3.3 at diagnosis to 3.6±2.7 six months later; most of the recovery (79%) occurred within the first month. No patient had complete restoration of pulmonary blood flow during the whole follow-up period. No difference was found between the number of ULS in right lung versus that in left lung at each interval. Recovery of blood flow was heavily affected by coexisting cardiac or pulmonary disease. In fact, those patients with underlying cardiopulmonary disease (49.2% of the total) showed significantly smaller perfusion improvement after six months (P<0.001). Eight patients (6 with and 2 without cardiopulmonary disease) had clinical and scintigraphic evidence of recurrent embolism during the follow-up period

  2. Electromechanical effects of bepridil on rabbit isolated hearts.

    OpenAIRE

    Anno, T.; Furuta, T.; Itoh, M.; Kodama, I.; Toyama, J.; Yamada, K.

    1984-01-01

    Electromechanical effects of a new antianginal agent, bepridil, on Langendorff-perfused rabbit hearts were compared with those of verapamil and lidocaine. Bepridil at concentrations above 2 X 10(-7)M caused a dose-related decrease in heart rate (HR), a prolongation of the atrio-His bundle conduction time (A-H interval) and a prolongation of the functional refractory period (FRP) of the atrioventricular (A-V) node. Similar changes in HR, A-H interval and the FRP of the A-V node were observed w...

  3. Utilization of tropical rabbits

    African Journals Online (AJOL)

    5,0' a,b"differ (P<0,05) for reproducing rabbits, and may aid the prevention of enteric diseases. In Trial 3, ADG of several tropical legumes was the same as that obtained with alfalfa (Table 3). Gains with guinea grass, cassava, stylosanthes and the winged bean were lower than with alfalfa. Digestibilityof the protein and fibre ...

  4. The CareRabbit

    NARCIS (Netherlands)

    Blom, Sanne; Stegwee, R.A.; Boere-Boonekamp, Magda

    2010-01-01

    The CareRabbit (ZorgKonijn) is an e-health device that can be used to play messages (e.g. text, MP3) sent through the Internet. It is used in children's departments in hospitals. Its aim is to make children feel comfortable and make their stay more pleasant. Motivation - Our goal is to investigate

  5. Static inflation attenuates ischemia/reperfusion injury in an isolated rat lung in situ.

    Science.gov (United States)

    Kao, Shang Jyh; Wang, David; Yeh, Diana Yu-Wung; Hsu, Kang; Hsu, Yung Hsiang; Chen, Hsing I

    2004-08-01

    Ischemia (I)/reperfusion (R) lung injury is an important clinical issue in lung transplantation. In the present study, we observed the effects of lung static inflation, different perfusates, and ventilatory gas with nitrogen or oxygen on the I/R-induced pulmonary damage. A total of 96 male Sprague-Dawley rats were used. The lung was isolated in situ. In an isolated lung, the capillary filtration coefficient (Kfc), lung weight gain (LWG), lung weight (LW)/body weight (BW) ratio, and protein concentration in BAL fluid (PCBAL) were measured or calculated to evaluate the degree of lung injury. Histologic examinations with hematoxylin-eosin staining were performed. I/R caused lung injury, as reflected by increases in Kfc, LWG, LW/BW, and PCBAL. The histopathologic picture revealed the presence of hyaline membrane formation and the infiltration of inflammatory cells. These values were significantly attenuated by static lung inflation. The I/R lung damage appeared to be less in the lung perfused with whole blood than in the lung perfused with an isotonic solution. Therapy with ventilatory air (ie, nitrogen or oxygen) did not alter the I/R lung damage. The data suggest that lung inflation is protective to I/R injury, irrespective of the type of ventilatory air used for treatment. The preservation of the lung for transplantation is better kept at a static inflation state and perfused with whole blood instead of an isotonic physiologic solution.

  6. Current lung water measurement methods in man

    International Nuclear Information System (INIS)

    Basset, G.; Moreau, F.; Marsac, J.; Capitini, R.; Botter, F.

    1979-01-01

    Two kinds of tracer method are used to estimate the lung water pools differing by the tracer intake and the sector observed. Airborne intake gives an estimate of the tissues irrigated by the lung and bronchial circulation, whereas vascular intake only shows the sectors perfused by the lung flow. Either of these methods is suitable for a general or regional analysis. In general methods the tracer is followed at the lung exit on expired air for the first method, on peripheral arterial blood for the second. Regional methods imply partial or whole-lung external detection systems [fr

  7. Lung release of HIPDM: A new index of lung dysfunction for clinical and experimental studies

    International Nuclear Information System (INIS)

    Pistolesi, M.; Miniati, M.; Ghelarducci, L.

    1985-01-01

    Lung uptake, metabolism and release of amines has been experimentally documented. The authors studied in rabbit and man the lung kinetics of radioiodinated N-N-N'-trimethyl-N'-(2-hydroxy-3-methyl-5-iodobenzyl)-1, 3-propanediamine (HIPDM). In rabbits, after i.v. injection, 95% of HIPDM is kept within the lungs and is then released with a mean time (t-bar) of several hours as assessed both in vivo, by gamma camera external counting (n=5; t-bar=7.0 hrs), and in vitro by measuring activity in lung homogenates at various times after injection (n=56; t-bar=7.6 hrs). In 10 healthy non smoking subjects t-bar was 6.4 +- 1 hrs, whereas it was 12.1 +- 2 hrs in 10 asymptomatic smokers with normal pulmonary function tests. Preliminary clinical studies showed that HIPDM lung release is delayed in non smoking patients with primary pulmonary hypertension (n=4; t-bar=11.5 +- 2 hrs) and to a greater extent in adult respiratory distress syndrome (n=4; t-bar=25.8 +- 5hrs), whereas it was not significantly affected in cardiogenic pulmonary edema (n=4; t-bar=8.8 +- 2 hrs). Hence, both smoke exposure and injury to the lung microcirculation may impair HIPDM lung kinetics. HIPDM external counting may therefore provide a new index of lung dysfunction in man. Rabbit can be used as a model to evaluate HIPDM lung kinetics in experimentally induced lung injury

  8. Ventilation-perfusion scans in neonatal regional pulmonary emphysema complicating ventilatory assistance

    International Nuclear Information System (INIS)

    Leonidas, J.C.; Moylan, F.M.B.; Kahn, P.C.; Ramenofsky, M.L.

    1978-01-01

    Two cases of ventilator-related neonatal lobar overexpansion with similar radiographic appearance, but probably different pathogenesis, are presented. In one infant, persistent interstitial lobar emphysema was confirmed by markedly decreased perfusion shown on scintigraphy; this information was of great value in predicting the beneficial effect of lobectomy. In the other case, ventilation and perfusion scans indicated functional value of the emphysematous lobe and correctly suggested conservative management. Radioisotope lung scans may provide valuable information regarding lung function in regional pulmonary emphysema associated with assisted ventilation in neonatal respiratory distress syndrome, and thus determine patient management

  9. Blood perfusion and pH monitoring in organs by laser-induced fluorescence spectroscopy

    Science.gov (United States)

    Vari, Sandor G.; Papazoglou, Theodore G.; Pergadia, Vani R.; Stavridi, Marigo; Snyder, Wendy J.; Papaioannou, Thanassis; Duffy, J. T.; Weiss, Andrew B.; Thomas, Reem; Grundfest, Warren S.

    1994-01-01

    Sensitivity of laser-induced fluorescence spectroscopy (LIFS) in detecting a change in tissue pH, and blood perfusion was determined. Rabbits were anesthetized, paralyzed, and mechanically ventilated. The arterial and venous blood supplies of the kidney were isolated and ligated to alter the perfusion. The femoral artery was cannulated to extract samples for blood gas analysis. A 308-nm XeCl was used as an excitation source. A 600 micrometers core diameter fiber was used for fluorescence acquisition, and the spectra analyzed by an optical multichannel analyzer (EG & G, OMA III). the corresponding intensity ratio R equals INADH / ICOLL was used as an index for respiratory acidosis. Blood perfusion was assessed using the following algorithm: (IELAS minus ICOLL) divided by (INADH minus ICOLL). The intensity ratio linearly decreased with the reduction of blood perfusion. When we totally occluded the artery the ratio decreased tenfold when compared to the ratio of a fully perfused kidney. Results of monitoring blood acidosis by laser-induced fluorescence spectroscopy shows a significant trend between pH and intensity ratio. Since all the slopes were negative, there is an obvious significant correlation between the pH and NADH.COLLAGEN RATIO. Blue-light-induced fluorescence measurements and ratio fluorometry is a sensitive method for monitoring blood perfusion and acidity or alkalinity of an organ.

  10. Differentiation of malignant and benign pulmonary nodules with first-pass dual-input perfusion CT

    International Nuclear Information System (INIS)

    Yuan, Xiaodong; Quan, Changbin; Cao, Jianxia; Ao, Guokun; Tian, Yuan; Li, Hong; Zhang, Jing

    2013-01-01

    To assess diagnostic performance of dual-input CT perfusion for distinguishing malignant from benign solitary pulmonary nodules (SPNs). Fifty-six consecutive subjects with SPNs underwent contrast-enhanced 320-row multidetector dynamic volume CT. The dual-input maximum slope CT perfusion analysis was employed to calculate the pulmonary flow (PF), bronchial flow (BF), and perfusion index (PI,=PF/(PF+BF)). Differences in perfusion parameters between malignant and benign tumours were assessed with histopathological diagnosis as the gold standard. Diagnostic value of the perfusion parameters was calculated using the receiver-operating characteristic (ROC) curve analysis. Amongst 56 SPNs, statistically significant differences in all three perfusion parameters were revealed between malignant and benign tumours. The PI demonstrated the biggest difference between malignancy and benignancy: 0.30 ± 0.07 vs. 0.51 ± 0.13, P < 0.001. The area under the PI ROC curve was 0.92, the largest of the three perfusion parameters, producing a sensitivity of 0.95, specificity of 0.83, positive likelihood ratio (+LR) of 5.59, and negative likelihood ratio (-LR) of 0.06 in identifying malignancy. The PI derived from the dual-input maximum slope CT perfusion analysis is a valuable biomarker for identifying malignancy in SPNs. PI may be potentially useful for lung cancer treatment planning and forecasting the therapeutic effect of radiotherapy treatment. (orig.)

  11. Metabolic acidosis may be as protective as hypercapnic acidosis in an ex-vivo model of severe ventilator-induced lung injury: a pilot study

    Directory of Open Access Journals (Sweden)

    Patsouris Efstratios

    2011-04-01

    Full Text Available Abstract Background There is mounting experimental evidence that hypercapnic acidosis protects against lung injury. However, it is unclear if acidosis per se rather than hypercapnia is responsible for this beneficial effect. Therefore, we sought to evaluate the effects of hypercapnic (respiratory versus normocapnic (metabolic acidosis in an ex vivo model of ventilator-induced lung injury (VILI. Methods Sixty New Zealand white rabbit ventilated and perfused heart-lung preparations were used. Six study groups were evaluated. Respiratory acidosis (RA, metabolic acidosis (MA and normocapnic-normoxic (Control - C groups were randomized into high and low peak inspiratory pressures, respectively. Each preparation was ventilated for 1 hour according to a standardized ventilation protocol. Lung injury was evaluated by means of pulmonary edema formation (weight gain, changes in ultrafiltration coefficient, mean pulmonary artery pressure changes as well as histological alterations. Results HPC group gained significantly greater weight than HPMA, HPRA and all three LP groups (P = 0.024, while no difference was observed between HPMA and HPRA groups regarding weight gain. Neither group differ on ultrafiltration coefficient. HPMA group experienced greater increase in the mean pulmonary artery pressure at 20 min (P = 0.0276 and 40 min (P = 0.0012 compared with all other groups. Histology scores were significantly greater in HP vs. LP groups (p Conclusions In our experimental VILI model both metabolic acidosis and hypercapnic acidosis attenuated VILI-induced pulmonary edema implying a mechanism other than possible synergistic effects of acidosis with CO2 for VILI attenuation.

  12. Metabolic acidosis may be as protective as hypercapnic acidosis in an ex-vivo model of severe ventilator-induced lung injury: a pilot study.

    Science.gov (United States)

    Kapetanakis, Theodoros; Siempos, Ilias I; Metaxas, Eugenios I; Kopterides, Petros; Agrogiannis, George; Patsouris, Efstratios; Lazaris, Andreas C; Stravodimos, Konstantinos G; Roussos, Charis; Armaganidis, Apostolos

    2011-04-13

    There is mounting experimental evidence that hypercapnic acidosis protects against lung injury. However, it is unclear if acidosis per se rather than hypercapnia is responsible for this beneficial effect. Therefore, we sought to evaluate the effects of hypercapnic (respiratory) versus normocapnic (metabolic) acidosis in an ex vivo model of ventilator-induced lung injury (VILI). Sixty New Zealand white rabbit ventilated and perfused heart-lung preparations were used. Six study groups were evaluated. Respiratory acidosis (RA), metabolic acidosis (MA) and normocapnic-normoxic (Control - C) groups were randomized into high and low peak inspiratory pressures, respectively. Each preparation was ventilated for 1 hour according to a standardized ventilation protocol. Lung injury was evaluated by means of pulmonary edema formation (weight gain), changes in ultrafiltration coefficient, mean pulmonary artery pressure changes as well as histological alterations. HPC group gained significantly greater weight than HPMA, HPRA and all three LP groups (P = 0.024), while no difference was observed between HPMA and HPRA groups regarding weight gain. Neither group differ on ultrafiltration coefficient. HPMA group experienced greater increase in the mean pulmonary artery pressure at 20 min (P = 0.0276) and 40 min (P = 0.0012) compared with all other groups. Histology scores were significantly greater in HP vs. LP groups (p < 0.001). In our experimental VILI model both metabolic acidosis and hypercapnic acidosis attenuated VILI-induced pulmonary edema implying a mechanism other than possible synergistic effects of acidosis with CO2 for VILI attenuation.

  13. Fabrication and perfusion culture of anatomically shaped artificial bone using stereolithography

    International Nuclear Information System (INIS)

    Du, Dajiang; Asaoka, Teruo; Ushida, Takashi; Furukawa, Katsuko S

    2014-01-01

    Because patient bone defects are usually varied and complicated in geometry, it would be preferred to fabricate custom-made artificial bone grafts that are anatomically specific to individual patient defects. Using a rabbit femoral segment as a bone reconstruction model, we successfully produced customized ceramic scaffolds by stereolithography, which not only had an anatomically correct external shape according to computed tomography data but also contained an interconnecting internal network of channels designed for perfusion culture. Rabbit bone marrow stromal cells were isolated and cultured with these scaffolds using a novel oscillatory perfusion system that was stereolithographically fabricated to fit well to the unique scaffold shapes. After five days of three-dimensional culture with oscillatory perfusion, the cells attached and proliferated homogenously in the scaffolds. However, control cells inside the scaffolds cultured under static conditions were dead after prolonged in vitro culture. Cellular DNA content and alkaline phosphatase activities were significantly higher in the perfusion group versus the static group. Therefore, anatomically correct artificial bone can be successfully constructed using stereolithography and oscillatory culture technology, and could be useful for bone engraftment and defect repair. (paper)

  14. Brain perfusion: computed tomography applications

    International Nuclear Information System (INIS)

    Miles, K.A.

    2004-01-01

    Within recent years, the broad introduction of fast multi-detector computed tomography (CT) systems and the availability of commercial software for perfusion analysis have made cerebral perfusion imaging with CT a practical technique for the clinical environment. The technique is widely available at low cost, accurate and easy to perform. Perfusion CT is particularly applicable to those clinical circumstances where patients already undergo CT for other reasons, including stroke, head injury, subarachnoid haemorrhage and radiotherapy planning. Future technical developments in multi-slice CT systems may diminish the current limitations of limited spatial coverage and radiation burden. CT perfusion imaging on combined PET-CT systems offers new opportunities to improve the evaluation of patients with cerebral ischaemia or tumours by demonstrating the relationship between cerebral blood flow and metabolism. Yet CT is often not perceived as a technique for imaging cerebral perfusion. This article reviews the use of CT for imaging cerebral perfusion, highlighting its advantages and disadvantages and draws comparisons between perfusion CT and magnetic resonance imaging. (orig.)

  15. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  16. In vivo determination of arterial collagen synthesis in atherosclerotic rabbits

    International Nuclear Information System (INIS)

    Opsahl, W.P.; DeLuca, D.J.; Ehrhart, L.A.

    1986-01-01

    Collagen and non-collagen protein synthesis rates were determined in vivo in tissues from rabbits fed a control or atherogenic diet supplemented with 2% peanut oil and 0.25% cholesterol for 4 months. Rabbits received a bolus intravenous injection of L-[ 3 H]-proline (1.0 mCi/kg) and unlabeled L-proline (7 mmoles/kg) in 0.9% NaCl. Plasma proline specific activity decreased only 20% over 5 hr and was similar to the specific activity of free proline in tissues. Thoracic aortas from atherosclerotic rabbits exhibited raised plaques covering at least 75% of the surface. Thoracic intima plus a portion of the media (TIM) was separated from the remaining media plus adventitia (TMA). Dry delipidated weight, total collagen content, and collagen as a percent of dry weight were increased significantly in the TIM of atherosclerotic rabbits. Collagen synthesis rates and collagen synthesis as a percent of total protein synthesis were likewise increased both in the TIM and in the abdominal aortas. No differences from controls either in collagen content or collagen synthesis rates were observed in the TMA, lung or skin. These results demonstrate for the first time in vivo that formation of atherosclerotic plaques is associated with increased rates of collagen synthesis. Furthermore, as previously observed with incubations in vitro, collagen synthesis was elevated to a greater extent than noncollagen protein synthesis in atherosclerotic aortas from rabbits fed cholesterol plus peanut oil

  17. Placental perfusion - a human alternative

    DEFF Research Database (Denmark)

    Mose, Tina; Knudsen, Lisbeth E

    2006-01-01

    Foetal exposures to environmental and medicinal products have impact on the growth of the foetus (e.g. cigarette smoke) and development of organs (e.g. methylmercury and Thalidomide). Perfusion studies of the human term placenta enable investigation of placental transport of chemical substances...... between the mother and foetus. Dual perfusion of a single cotyledon in the human placenta can contribute to a better understanding of the placental barrier, transport rate and mechanisms of different substances and placental metabolism. The perfusion system has recently been established in Copenhagen...

  18. Laparoscopic ovariectomy in rabbits

    Directory of Open Access Journals (Sweden)

    M. S. Al-Badrany

    2009-01-01

    Full Text Available A comparative evaluation of three different techniques of laparoscopic ovariectomy was carried out in 33 healthy female in rabbits, which included resection and removal of ovary after clip application, electrocautery of the ovary, then resection, and pulling ovary outside abdomen, ligation by silk, then ovary was removed. The ovaries and associated structures were better visualized by laparoscopy and all three techniques were carried out perfectly. All rabbits after operation were healthy and they were monitored for one month after operation. However, 3 of them died after operation, two of them died due to bleeding and the other of them died due to unknown causes. General anesthesia by using ketamine-xylazine i.m., was suitable for this technique, and the anesthesia provided good analgesia and good muscle relaxation. CO2 was used to establish pneumoperitoneum. In conclusion, resection and removal of the ovaries after clip application technique was found superior to the other two techniques.

  19. Estimation of Lung Ventilation

    Science.gov (United States)

    Ding, Kai; Cao, Kunlin; Du, Kaifang; Amelon, Ryan; Christensen, Gary E.; Raghavan, Madhavan; Reinhardt, Joseph M.

    Since the primary function of the lung is gas exchange, ventilation can be interpreted as an index of lung function in addition to perfusion. Injury and disease processes can alter lung function on a global and/or a local level. MDCT can be used to acquire multiple static breath-hold CT images of the lung taken at different lung volumes, or with proper respiratory control, 4DCT images of the lung reconstructed at different respiratory phases. Image registration can be applied to this data to estimate a deformation field that transforms the lung from one volume configuration to the other. This deformation field can be analyzed to estimate local lung tissue expansion, calculate voxel-by-voxel intensity change, and make biomechanical measurements. The physiologic significance of the registration-based measures of respiratory function can be established by comparing to more conventional measurements, such as nuclear medicine or contrast wash-in/wash-out studies with CT or MR. An important emerging application of these methods is the detection of pulmonary function change in subjects undergoing radiation therapy (RT) for lung cancer. During RT, treatment is commonly limited to sub-therapeutic doses due to unintended toxicity to normal lung tissue. Measurement of pulmonary function may be useful as a planning tool during RT planning, may be useful for tracking the progression of toxicity to nearby normal tissue during RT, and can be used to evaluate the effectiveness of a treatment post-therapy. This chapter reviews the basic measures to estimate regional ventilation from image registration of CT images, the comparison of them to the existing golden standard and the application in radiation therapy.

  20. Detection of rabbit Haemorrhagic disease virus 2 during the wild rabbit (Oryctolagus cuniculus) eradication from the Berlengas archipelago, Portugal.

    Science.gov (United States)

    Abade Dos Santos, F A; Carvalho, C; Nuno, Oliveira; Correia, J J; Henriques, M; Peleteiro, M C; Fevereiro, M; Duarte, M D

    2017-11-15

    In the regular wildlife monitoring action carried out in the summer of the past few years at the Berlenga Island, wild rabbits (Oryctolagus cuniculus) have been repeatedly found dead. However, the origin of those deaths was never investigated. Our aim was to investigate the cause of death of 11 rabbits collected between April and May 2016. While screening samples from rabbit carcasses for the major viral rabbit pathogens, five tested positive to RHDV2 but all were negative for RHDV and myxoma virus (MYXV). For six RHDV2-negative specimens, emaciation and parasitism were considered the most probable cause of death. Lesions identified in the RHDV2-positive rabbits included non-suppurative diffuse hepatic necrosis and pulmonary lesions varying from congestion and oedema of the lungs to interstitial pneumonia. Sequencing analysis of the vp60 gene obtained from two specimens showed identical vp60 sequences. Comparison with other known RHDV2 strains from public databases through BLAST analysis revealed a closer similarity with strains from Alentejo collected during 2013. Maximum Likelihood and Bayesian phylogenetic analysis showed that the 2016 strains from the archipelago have a higher resemblance with a group of strains mostly collected in the South of Portugal between 2013 and 2014. The results suggest that RHDV2 may have been introduced on the Berlenga Island a few years ago, having evolved separately from mainland strains due to insularity.

  1. Perfusion study in the pulmonary hilar region by SPECT

    International Nuclear Information System (INIS)

    Satoh, Katashi; Tanabe, Masatada; Kawase, Yoshiro

    1990-01-01

    Alveoli in the hilar region comprise the peripheral area containing daughter branches from subsegmental or one more divisional peripheral bronchi. Pulmonary perfusion in hilar region was examined by SPECT (single photon emission CT) in ten normal volunteers. ROI (region of interest) in the axial images were set in the hilar region, the upper, middle and lower lung fields with 10.8 mm thickness. Counts/one pixel (C/P) were calculated in these ROI. There was a tendency of C/P increase from upper to lower lung field. And there were no significant differences in C/P increase between hilar region and other axial fields. In the chronic obstructive pulmonary diseases, however, ventilation studies in the previous reports using Xe dynamic CT or PET (positron emission tomography) showed differences between outer region and hilar region. This method will be expected to evaluate the pulmonary perfusion not only in the whole lung but in different lung areas, including the hilar region in the chronic obstructive pulmonary diseases. (author)

  2. Rabbit Model of Retinoblastoma

    Directory of Open Access Journals (Sweden)

    Shin Jeong Kang

    2011-01-01

    Full Text Available We created a rabbit model of retinoblastoma and confirmed the tumor clinically and histopathologically. Seventeen New Zealand rabbits were immunosuppressed with cyclosporin A at doses of 10–15 mg/kg. At day 3, the animals received a 30 μl subretinal injection of 1×106 cultured WERI retinoblastoma cells. Digital fundus images were captured before euthanasia, and the eyes were submitted for histopathology. Retinoblastoma cells grew in all the inoculated eyes and established a tumor under the retina and/or in the vitreous. New blood vessels in the tumor were observed starting at week 5. Cuffs of viable tumor cells surrounded the blood vessels with regions of necrosis present at 70–80 μm from nutrient vessels. Occasional tumor seeds in the vitreous histologically exhibited central necrosis. This rabbit model demonstrated similar fundus appearance and pathologic features to human retinoblastoma and may be used as a model to test various routes of drug delivery for retinoblastoma.

  3. Hepatic perfusion during hepatic artery infusion chemotherapy: Evaluation with perfusion CT and perfusion scintigraphy

    International Nuclear Information System (INIS)

    Miller, D.L.; Carrasquillo, J.A.; Lutz, R.J.; Chang, A.E.

    1989-01-01

    The standard method for the evaluation of hepatic perfusion during hepatic artery infusion (HAI) chemotherapy is planar hepatic artery perfusion scintigraphy (HAPS). Planar HAPS was performed with 2 mCi of [99mTc] macroaggregated albumin infused at 1 ml/min and compared with single photon emission CT (SPECT) HAPS and with a new study, CT performed during the slow injection of contrast material through the HAI catheter (HAI-CT). Thirteen patients underwent 16 HAI-CT studies, 14 planar HAPS studies, and 9 SPECT HAPS studies. In 13 of 14 studies (93%) HAI-CT and planar HAPS were in complete agreement as to the perfusion pattern of intrahepatic metastases and normal liver. In nine studies where all modalities were performed, the findings identified by HAI-CT and planar HAPS agreed in all cases, whereas the results of two SPECT scans disagreed with the other studies. With respect to perfusion of individual metastases, 14 of 14 HAI-CT studies, 12 of 13 planar HAPS studies, and 9 of 9 SPECT HAPS studies correctly demonstrated the perfusion status of individual lesions as indicated by the pattern of changes in tumor size determined on CT obtained before and after the perfusion studies. Hepatic artery infusion CT was superior for delineation of individual metastases, particularly small lesions, and for the evaluation of nonperfused portions of the liver. Planar HAPS detected extrahepatic perfusion in four patients, and this was not detected by HAI-CT. We conclude that HAI-CT and scintigraphy are complementary techniques. Hepatic artery infusion CT has advantages for the evaluation of intrahepatic perfusion, and planar HAPS is superior to HAI-CT for the detection of extrahepatic perfusion

  4. Estimation of Radiation Exposure of 128-Slice 4D-Perfusion CT for the Assessment of Tumor Vascularity

    Science.gov (United States)

    Horger, Marius; Buchgeister, Markus; Fenchel, Michael; Thomas, Christoph; Boehringer, Nadine; Schulze, Maximilian; Tsiflikas, Ilias; Claussen, Claus D.; Heuschmid, Martin

    2010-01-01

    Objective We aimed to estimate the effective dose of 4D-Perfusion-CT protocols of the lung, liver, and pelvis for the assessment of tumor vascularity. Materials and Methods An Alderson-Rando phantom equipped with thermoluminescent dosimeters was used to determine the effective dose values of 4D-Perfusion-CT. Phantom measurements were performed on a 128-slice single-source scanner in adaptive 4D-spiral-mode with bidirectional table movement and a total scan range of 69 mm over a time period of nearly 120 seconds (26 scans). Perfusion measurements were simulated for the lung, liver, and pelvis under the following conditions: lung (80 kV, 60 mAs), liver (80 kV/80 mAs and 80 kV/120 mAs), pelvis (100 kV/80 mAs and 100 kV/120 mAs). Results Depending on gender, the evaluated body region and scan protocol, an effective whole-body dose between 2.9-12.2 mSv, was determined. The radiation exposure administered to gender-specific organs like the female breast tissue (lung perfusion) or to the ovaries (pelvic perfusion) led to an increase in the female specific dose by 86% and 100% in perfusion scans of the lung and the pelvis, respectively. Conclusion Due to a significant radiation dose of 4D-perfusion-CT protocols, the responsible use of this new promising technique is mandatory. Gender- and organ-specific differences should be considered for indication and planning of tumor perfusion scans. PMID:20808699

  5. Estimation of Radiation Exposure of 128-Slice 4D-Perfusion CT for the Assessment of Tumor Vascularity

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik; Horger, Marius; Buchgeister, Markus; Fenchel, Michael; Thomas, Christoph; Boehringer, Nadine; Schulze, Maximilian; Tsiflikas, Ilias; Claussen, Claus D.; Heuschmid, Martin [University Hospital Tuebingen, Tuebingen (Germany)

    2010-10-15

    We aimed to estimate the effective dose of 4D-Perfusion-CT protocols of the lung, liver, and pelvis for the assessment of tumor vascularity. An Alderson-Rando phantom equipped with thermoluminescent dosimeters was used to determine the effective dose values of 4D Perfusion-CT. Phantom measurements were performed on a 128-slice single source scanner in adaptive 4D-spiral-mode with bidirectional table movement and a total scan range of 69 mm over a time period of nearly 120 seconds (26 scans). Perfusion measurements were simulated for the lung, liver, and pelvis under the following conditions: lung (80 kV, 60 mAs), liver (80 kV/80 mAs and 80 kV/120 mAs), pelvis (100 kV/80 mAs and 100 kV/120 mAs). Depending on gender, the evaluated body region and scan protocol, an effective whole-body dose between 2.9-12.2 mSv, was determined. The radiation exposure administered to gender-specific organs like the female breast tissue (lung perfusion) or to the ovaries (pelvic perfusion) led to an increase in the female specific dose by 86% and 100% in perfusion scans of the lung and the pelvis, respectively. Due to a significant radiation dose of 4D-perfusion-CT protocols, the responsible use of this new promising technique is mandatory. Gender- and organ-specific differences should be considered for indication and planning of tumor perfusion scans

  6. Regional distribution of ventilation-perfusion ratio in patients with interstitial pneumonia using Kr-81m

    International Nuclear Information System (INIS)

    Sekine, Hiroshi; Kawakami, Kenji; Shimada, Takao

    1983-01-01

    In order to know the pathophysiological change of interstitial pneumonia, it is important to detect the morphological change of vascular and air way systems in the lung. The study group consisted of 12 patients of interstitial pneumonia including IIP, PSS, RA, sarcoidosis, and hypersensitive pneumonia. The Kr-81m bolus inhalation from 3 different lung volumes were analyzed to detect regional ventilation abnormalities. The regional distribution of ventilation-perfusion ratio (V/Q) in the lung was obtained from the continuous inhalation and infusion Kr-81 m. In 7 patients, regional distribution of V/Q was also measured at rest and during exercise. In advanced stage of interstitial pneumonia, radioactivity in lower lung fields was decreased in bolus inhalation from TLC-400 ml lung volume, and present in lower lung in bolus inhalation from RV level. These findings are representing air way rigidity especially in lower lung fields. However, in early stage or reversible cases, it is difficult to detect the abnormal distribution of radioactivity in lung, in spite of decreased PO 2 . So it seems impossible to screen early stage or reversible cases of interstitial pneumonia by bolus inhalation method alone. At rest for normal subjects in the upright position, the apical zone had a high V/Q, but in the lower parts two third of V/Q distribution was relatively homogeneous. During exercise at 50W, the distribution became more uniform. In most cases of the disease, weak exercise (less than 40W) produced the same uniform V/Q distribution. It should be noted that in the disease not only was perfusion in upper lung fields increased, but that perfusion of lower lung fields was reduced. So late in the cource of extension of the disease, pulmonary vascular bed in the lower lung fields is restricted.(J.P.N.)

  7. Hydrostatic determinants of cerebral perfusion

    International Nuclear Information System (INIS)

    Wagner, E.M.; Traystman, R.J.

    1986-01-01

    We examined the cerebral blood flow response to alterations in perfusion pressure mediated through decreases in mean arterial pressure, increases in cerebrospinal fluid (CSF) pressure, and increases in jugular venous (JV) pressure in 42 pentobarbital anesthetized dogs. Each of these three pressures was independently controlled. Cerebral perfusion pressure was defined as mean arterial pressure minus JV or CSF pressure, depending on which was greater. Mean hemispheric blood flow was measured with the