WorldWideScience

Sample records for performed laboratory studies

  1. Malaria Laboratory Diagnostic Performance: Case studies of two ...

    African Journals Online (AJOL)

    Advantages of rapid diagnostic tests when compared with microscopy are simple to perform, fast, low ... The study was conducted to establish the performance of laboratory diagnosis of malaria in local Malawi .... Government of Malawi.

  2. Evaluation of the analytic performance of laboratories: inter-laboratorial study of the spectroscopy of atomic absorption

    International Nuclear Information System (INIS)

    Wong Wong, S. M.

    1996-01-01

    The author made an inter-laboratorial study, with the participation of 18 national laboratories, that have spectrophotometer of atomic absorption. To evaluate the methods of analysis of lead, sodium, potasium, calcium, magnesium, zinc, copper, manganese, and iron, in the ambit of mg/l. The samples, distributed in four rounds to the laboratories, were prepared from primary patterns, deionized and distilled water. The study evaluated the homogeneity and stability, and verified its concentration, using as a reference method, the spectrometry method of Inductively Coupled Plasma emission (1CP). To obtain the characteristics of analytic performance, it applied the norm ASTM E 691. To evaluated the analytic performance, it used harmonized protocol of the International Union of Pure and applied chemistry (IUPAC). The study obtained the 29% of the laboratories had a satisfactory analytic performance, 9% had a questionable performance and 62% made an unsatisfactory analytic performance, according to the IUPAC norm. The results of the values of the characteristic performance method, show that there is no intercomparability between the laboratories, which is attributed to the different methodologies of analysis. (S. Grainger)

  3. COGNITIVE PERFORMANCE LABORATORY

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory conducts basic and applied human research studies to characterize cognitive performance as influenced by militarily-relevant contextual and physical...

  4. The impact of laboratory quality assurance standards on laboratory operational performance

    Directory of Open Access Journals (Sweden)

    E Ratseou

    2014-01-01

    Full Text Available It has become a trend for companies to implement and be certified to various quality management systems so as to improve consistency, reliability, and quality of product delivery to customers. The most common quality management systems adopted are the ISO 9000 series of standards for manufacturing and services related organisations, with ISO 17025 and Good Laboratory Practices (GLP standards adopted specifically by laboratories as quality assurance initiatives. There are various reports on the impact of the ISO 9000 series on organisational performance but no studies or reports have been done on the performance of laboratory standards. Therefore this article reports on a study conducted to investigate the impact of ISO 17025 and GLP on the operational performance of both commercial and non-commercial laboratories. A qualitative research study was conducted to examine the impact standards on the aspects of health and safety, supplier selection and performance, human resources, customer satisfaction and profitability of the laboratory. The data collected suggest that there is no difference in laboratory operational performance with or without the standards. In other words it appears that the basic fundamental requirements inherent with laboratories are sufficient to perform both operationally and optimally. This leads to the view that standards are implemented as a customer requirement and not as an operational requirement.

  5. The 1993 QUASIMEME laboratory-performance study: chlorobiphenyls in fish oil and standard solutions

    NARCIS (Netherlands)

    Wells, D.E.; Boer, de J.

    1994-01-01

    A laboratory-performance study has been undertaken to improve the measurement of chlorobiphenyls in marine biota as part of the QUASIMEME (EU - Measurement and Testing) project. Fifty-two laboratories were invited to participate, of which 47 returned data on nine congeners in iso-octane solution and

  6. Development of a Laboratory Test Procedure to Evaluate Tack Coat Performance

    OpenAIRE

    YILDIRIM, Yetkin; SMIT, André de Fortier; KORKMAZ, Armagan

    2014-01-01

    A laboratory testing procedure is presented, the results of which may be used for determining the best combination of tack coat type, mixture type, and application rate to be applied in the field for optimum performance. Tack coat related performance results were determined from Hamburg wheel tracking and simple shear tests on laboratory prepared specimens. This study was undertaken to evaluate the shear strength performance of tack coats under laboratory-controlled conditions. The ...

  7. Laboratory performance evaluation reports for management

    International Nuclear Information System (INIS)

    Lindahl, P.C.; Hensley, J.E.; Bass, D.A.; Johnson, P.L.; Marr, J.J.; Streets, W.E.; Warren, S.W.; Newberry, R.W.

    1995-01-01

    In support of the US DOE's environmental restoration efforts, the Integrated Performance Evaluation Program (IPEP) was developed to produce laboratory performance evaluation reports for management. These reports will provide information necessary to allow DOE headquarters and field offices to determine whether or not contracted analytical laboratories have the capability to produce environmental data of the quality necessary for the remediation program. This document describes the management report

  8. Evaluating laboratory key performance using quality indicators in Alexandria University Hospital Clinical Chemistry Laboratories.

    Science.gov (United States)

    Rizk, Mostafa M; Zaki, Adel; Hossam, Nermine; Aboul-Ela, Yasmin

    2014-12-01

    The performance of clinical laboratories plays a fundamental role in the quality and effectiveness of healthcare. To evaluate the laboratory performance in Alexandria University Hospital Clinical Laboratories using key quality indicators and to compare the performance before and after an improvement plan based on ISO 15189 standards. The study was carried out on inpatient samples for a period of 7 months that was divided into three phases: phase I included data collection for evaluation of the existing process before improvement (March-May 2012); an intermediate phase, which included corrective, preventive action, quality initiative and steps for improvement (June 2012); and phase II, which included data collection for evaluation of the process after improvement (July 2012-September 2012). In terms of the preanalytical indicators, incomplete request forms in phase I showed that the total number of received requests were 31 944, with a percentage of defected request of 33.66%; whereas in phase II, there was a significant reduction in all defected request items (Plaboratories.

  9. Costs of examinations performed in a hospital laboratory in Chile.

    Science.gov (United States)

    Andrade, Germán Lobos; Palma, Carolina Salas

    2018-01-01

    To determine the total average costs related to laboratory examinations performed in a hospital laboratory in Chile. Retrospective study with data from July 2014 to June 2015. 92 examinations classified in ten groups were selected according to the analysis methodology. The costs were estimated as the sum of direct and indirect laboratory costs and indirect institutional factors. The average values obtained for the costs according to examination group (in USD) were: 1.79 (clinical chemistry), 10.21 (immunoassay techniques), 13.27 (coagulation), 26.06 (high-performance liquid chromatography), 21.2 (immunological), 3.85 (gases and electrolytes), 156.48 (cytogenetic), 1.38 (urine), 4.02 (automated hematological), 4.93 (manual hematological). The value, or service fee, returned to public institutions who perform laboratory services does not adequately reflect the true total average production costs of examinations.

  10. Development of performance assessment instrument based contextual learning for measuring students laboratory skills

    Science.gov (United States)

    Susilaningsih, E.; Khotimah, K.; Nurhayati, S.

    2018-04-01

    The assessment of laboratory skill in general hasn’t specific guideline in assessment, while the individual assessment of students during a performance and skill in performing laboratory is still not been observed and measured properly. Alternative assessment that can be used to measure student laboratory skill is use performance assessment. The purpose of this study was to determine whether the performance assessment instrument that the result of research can be used to assess basic skills student laboratory. This research was conducted by the Research and Development. The result of the data analysis performance assessment instruments developed feasible to implement and validation result 62.5 with very good categories for observation sheets laboratory skills and all of the components with the very good category. The procedure is the preliminary stages of research and development stages. Preliminary stages are divided in two, namely the field studies and literature studies. The development stages are divided into several parts, namely 1) development of the type instrument, 2) validation by an expert, 3) a limited scale trial, 4) large-scale trials and 5) implementation of the product. The instrument included in the category of effective because 26 from 29 students have very high laboratory skill and high laboratory skill. The research of performance assessment instrument is standard and can be used to assess basic skill student laboratory.

  11. Laboratory microfusion capability study

    International Nuclear Information System (INIS)

    1993-05-01

    The purpose of this study is to elucidate the issues involved in developing a Laboratory Microfusion Capability (LMC) which is the major objective of the Inertial Confinement Fusion (ICF) program within the purview of the Department of Energy's Defense Programs. The study was initiated to support a number of DOE management needs: to provide insight for the evolution of the ICF program; to afford guidance to the ICF laboratories in planning their research and development programs; to inform Congress and others of the details and implications of the LMC; to identify criteria for selection of a concept for the Laboratory Microfusion Facility and to develop a coordinated plan for the realization of an LMC. As originally proposed, the LMC study was divided into two phases. The first phase identifies the purpose and potential utility of the LMC, the regime of its performance parameters, driver independent design issues and requirements, its development goals and requirements, and associated technical, management, staffing, environmental, and other developmental and operational issues. The second phase addresses driver-dependent issues such as specific design, range of performance capabilities, and cost. The study includes four driver options; the neodymium-glass solid state laser, the krypton fluoride excimer gas laser, the light-ion accelerator, and the heavy-ion induction linear accelerator. The results of the Phase II study are described in the present report

  12. Performance evaluation of the food and environmental monitoring radio-analytical laboratory in Ghana

    International Nuclear Information System (INIS)

    Agyeman, Lilian Ataa

    2016-06-01

    Since the establishment of the Radiation Protection Institute’s Food and Environmental Laboratory in 1988, there has never been any thorough evaluation of the activities of the facility to provide assurance of the quality of analytical results produced by the laboratory. The objective of this study, therefore, was to assess the performance level of the Food and Environmental monitoring laboratory with respect to the requirements for a standard analytical laboratory (IAEA, 1989) and ISO 17025. The study focused on the performance of the Gamma Spectrometry laboratory of the Radiation Protection Institute, Ghana Atomic Energy Commission which has been involved in monitoring of radionuclides in food and environmental samples. In doing that, data from 1988 to 2015 was reviewed to ascertain whether the Laboratory has being performing as required in providing quality results on food and environmental samples measured. Besides this data (records kept), the evaluation also covered some Technical Quality Control measures, such as Energy and Efficiency Calibration, that need to be put in place for such laboratories. The laboratory meets almost all conditions and equipment requirements of IAEA (1989), however the laboratory falls short of the management requirements of ISO 17025. Based on the results it was recommended, among others, that management of the laboratory should ensure there are procedures for how calibration and testing is performed for different types of equipment and also the competence of all who operate specific equipment, perform tests, evaluate results and sign test reports ensured. (au)

  13. Extra-analytical quality indicators and laboratory performances.

    Science.gov (United States)

    Sciacovelli, Laura; Aita, Ada; Plebani, Mario

    2017-07-01

    In the last few years much progress has been made in raising the awareness of laboratory medicine professionals about the effectiveness of quality indicators (QIs) in monitoring, and improving upon, performances in the extra-analytical phases of the Total Testing Process (TTP). An effective system for management of QIs includes the implementation of an internal assessment system and participation in inter-laboratory comparison. A well-designed internal assessment system allows the identification of critical activities and their systematic monitoring. Active participation in inter-laboratory comparison provides information on the performance level of one laboratory with respect to that of other participating laboratories. In order to guarantee the use of appropriate QIs and facilitate their implementation, many laboratories have adopted the Model of Quality Indicators (MQI) proposed by Working Group "Laboratory Errors and Patient Safety" (WG-LEPS) of IFCC, since 2008, which is the result of international consensus and continuous experimentation, and updating to meet new, constantly emerging needs. Data from participating laboratories are collected monthly and reports describing the statistical results and evaluating laboratory data, utilizing the Six Sigma metric, issued regularly. Although the results demonstrate that the processes need to be improved upon, overall the comparison with data collected in 2014 shows a general stability of quality levels and that an improvement has been achieved over time for some activities. The continuous monitoring of QI data allows identification all possible improvements, thus highlighting the value of participation in the inter-laboratory program proposed by WG-LEPS. The active participation of numerous laboratories will guarantee an ever more significant State-of-the-Art, promote the reduction of errors and improve quality of the TTP, thus guaranteeing patient safety. Copyright © 2017. Published by Elsevier Inc.

  14. Science laboratory behavior strategies of students relative to performance in and attitude to laboratory work

    Science.gov (United States)

    Okebukola, Peter Akinsola

    The relationship between science laboratory behavior strategies of students and performance in and attitude to laboratory work was investigated in an observational study of 160 laboratory sessions involving 600 class five (eleventh grade) biology students. Zero-order correlations between the behavior strategies and outcome measures reveal a set of low to strong relationships. Transmitting information, listening and nonlesson related behaviors exhibited low correlations with practical skills and the attitude measure. The correlations between manipulating apparatus and observation with practical skills measures were found to be strong. Multiple correlation analysis revealed that the behaviors of students in the laboratories observed accounted for a large percentage of the variance in the scores on manipulative skills and a low percentage on interpretation of data, responsibility, initiative, and work habits. One significant canonical correlation emerged. The loadings on this canonical variate indicate that the practical skills measures, i.e., planning and design, manipulative skills and conduct of experiments, observation and recording of data, and attitude to laboratory work made primary contributions to the canonical relationship. Suggestions as to how students can be encouraged to go beyond cookbook-like laboratories and develop a more favorable attitude to laboratory work are made.

  15. FOOTWEAR PERFORMANCE LABORATORY

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory provides biomechanical and physical analyses for both military and commercial footwear. The laboratory contains equipment that is integral to the us...

  16. Performance testing of radiobioassay laboratories: in-vivo measurements, pilot study report

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, A.V.; Fisher, D.R.; Reece, W.D.; MacLellan, J.A.

    1986-10-01

    This document describes a project to evaluate the in-vivo counting performance criteria of draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. The draft ANSI Standard provides guidance to in-vivo counting facilities regarding the precision and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. The draft ANSI Standard was evaluated by conducting an intercomparison test involving a number of whole-body counting facilities. The testing involved three types of measurements: chest counting for detection of radioactive materials in the lung, whole-body counting for detection of uniformly distributed activity, and neck counting for detection of radioactive material concentrated in the thyroid. Results of the first-round intercomparison test are presented in this report. The appropriateness of the draft Standard performance criteria was judged by the measurement results reported by participating in-vivo counting facilities. The intercomparison testing showed that some laboratories had difficulty meeting the performance criteria specified in the draft ANSI Standard N13.30.

  17. Performance testing of radiobioassay laboratories: in-vivo measurements, pilot study report

    International Nuclear Information System (INIS)

    Robinson, A.V.; Fisher, D.R.; Reece, W.D.; MacLellan, J.A.

    1986-10-01

    This document describes a project to evaluate the in-vivo counting performance criteria of draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. The draft ANSI Standard provides guidance to in-vivo counting facilities regarding the precision and accuracy of measurements for certain categories of commonly assayed radionuclides and critical regions of the body. The draft ANSI Standard was evaluated by conducting an intercomparison test involving a number of whole-body counting facilities. The testing involved three types of measurements: chest counting for detection of radioactive materials in the lung, whole-body counting for detection of uniformly distributed activity, and neck counting for detection of radioactive material concentrated in the thyroid. Results of the first-round intercomparison test are presented in this report. The appropriateness of the draft Standard performance criteria was judged by the measurement results reported by participating in-vivo counting facilities. The intercomparison testing showed that some laboratories had difficulty meeting the performance criteria specified in the draft ANSI Standard N13.30

  18. Recommended procedures for performance testing of radiobioassay laboratories: Volume 1, Quality assurance

    International Nuclear Information System (INIS)

    Fenrick, H.W.; MacLellan, J.A.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed in response to a concern expressed by the US Department of Energy and US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard specifies the criteria for defining the procedures necessary to establish a bioassay performance-testing laboratory and program. The testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped define responsibilities and develop procedures as part of an effort to evaluate the draft ANSI N13.30 performance criteria for quality assurance at bioassay laboratories. This report recommends elements of quality assurance and quality control responsibilities for the bioassay performance-testing laboratory program, including the qualification and performance of personnel and the calibration, certification, and performance of equipment. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented. 15 refs

  19. Performance evaluation of tuberculosis smear microscopists working at rechecking laboratories in Ethiopia

    Directory of Open Access Journals (Sweden)

    Habtamu Asrat

    2017-04-01

    Objective: This study assessed the performance of tuberculosis smear microscopists at external quality assessment rechecking laboratories in Ethiopia. Methods: A cross-sectional study was conducted at 81 laboratories from April to July 2015. Panel slides were prepared and validated at the National Tuberculosis Reference Laboratory. The validated panel slides were used to evaluate the performance of microscopists at these laboratories compared with readers from the reference laboratory. Results: A total of 389 external quality assessment rechecking laboratory microscopists participated in the study, of which 268 (68.9% worked at hospitals, 241 (62% had more than five years of work experience, 201 (51.7% held Bachelors degrees, and 319 (82% reported tuberculosis smear microscopy training. Overall, 324 (83.3% participants scored ≥ 80%. Sensitivity for detecting tuberculosis bacilli was 84.5% and specificity was 93.1%. The overall percent agreement between participants and reference readers was 87.1 (kappa=0.72. All 10 slides were correctly read (i.e., scored 100% by 80 (20.6% participants, 156 (40.1% scored 90% – 95%, 88 (22.6% scored 80% – 85% and 65 (16.7% scored below 80%. There were 806 (20.7% total errors, with 143 (3.7% major and 663 (17% minor errors. Conclusion: The overall performance of participants in reading the slides showed good agreement with the reference readers. Most errors were minor, and the ability to detect tuberculosis bacilli can be improved through building the capacity of professionals.

  20. The balanced scorecard: sustainable performance assessment for forensic laboratories.

    Science.gov (United States)

    Houck, Max; Speaker, Paul J; Fleming, Arron Scott; Riley, Richard A

    2012-12-01

    The purpose of this article is to introduce the concept of the balanced scorecard into the laboratory management environment. The balanced scorecard is a performance measurement matrix designed to capture financial and non-financial metrics that provide insight into the critical success factors for an organization, effectively aligning organization strategy to key performance objectives. The scorecard helps organizational leaders by providing balance from two perspectives. First, it ensures an appropriate mix of performance metrics from across the organization to achieve operational excellence; thereby the balanced scorecard ensures that no single or limited group of metrics dominates the assessment process, possibly leading to long-term inferior performance. Second, the balanced scorecard helps leaders offset short term performance pressures by giving recognition and weight to long-term laboratory needs that, if not properly addressed, might jeopardize future laboratory performance. Copyright © 2012 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  1. Performance testing of UK personal dosimetry laboratories

    CERN Document Server

    Marshall, T O

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it...

  2. Performance Indicators For Quality In Surgical And Laboratory ...

    African Journals Online (AJOL)

    Methodology: Hospital records were reviewed and information recorded for planned and postponed operations, laboratory equipment, reagents, laboratory tests and quality assurance programmes. Results: In the year 2001 a total of 4332 non-emergency operations were planned, 3313 operations were performed and 1019 ...

  3. Performance testing of UK personal dosimetry laboratories

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it are also estimated. (author)

  4. Laboratory infrastructure driven key performance indicator development using the smart grid architecture model

    DEFF Research Database (Denmark)

    Syed, Mazheruddin H.; Guillo-Sansano, Efren; Blair, Steven M.

    2017-01-01

    This study presents a methodology for collaboratively designing laboratory experiments and developing key performance indicators for the testing and validation of novel power system control architectures in multiple laboratory environments. The contribution makes use of the smart grid architecture...

  5. Environmental Measurements Laboratory 2002 Unit Performance Plan

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-10-01

    This EML Unit Performance Plan provides the key goals and performance measures for FY 2002 and continuing to FY 2003. The purpose of the Plan is to inform EML's stakeholders and customers of the Laboratory's products and services, and its accomplishments and future challenges. Also incorporated in the Unit Performance Plan is EML's Communication Plan for FY 2002.

  6. Investigation and Analysis of Hemoglobin A1c Measurement Systems' Performance for 135 Laboratories in China

    Directory of Open Access Journals (Sweden)

    Hai-Jian Zhao

    2017-01-01

    Conclusions: This study indicated that, although participating laboratories were laboratories with better performance in China, the performances were still unsatisfactory. Actions should be taken to improve HbA1c measurement performance before we can include HbA1c assays in diabetes diagnosis in China.

  7. Residents' surgical performance during the laboratory years: an analysis of rule-based errors.

    Science.gov (United States)

    Nathwani, Jay N; Wise, Brett J; Garren, Margaret E; Mohamadipanah, Hossein; Van Beek, Nicole; DiMarco, Shannon M; Pugh, Carla M

    2017-11-01

    Nearly one-third of surgical residents will enter into academic development during their surgical residency by dedicating time to a research fellowship for 1-3 y. Major interest lies in understanding how laboratory residents' surgical skills are affected by minimal clinical exposure during academic development. A widely held concern is that the time away from clinical exposure results in surgical skills decay. This study examines the impact of the academic development years on residents' operative performance. We hypothesize that the use of repeated, annual assessments may result in learning even without individual feedback on participants simulated performance. Surgical performance data were collected from laboratory residents (postgraduate years 2-5) during the summers of 2014, 2015, and 2016. Residents had 15 min to complete a shortened, simulated laparoscopic ventral hernia repair procedure. Final hernia repair skins from all participants were scored using a previously validated checklist. An analysis of variance test compared the mean performance scores of repeat participants to those of first time participants. Twenty-seven (37% female) laboratory residents provided 2-year assessment data over the 3-year span of the study. Second time performance revealed improvement from a mean score of 14 (standard error = 1.0) in the first year to 17.2 (SD = 0.9) in the second year, (F[1, 52] = 5.6, P = 0.022). Detailed analysis demonstrated improvement in performance for 3 grading criteria that were considered to be rule-based errors. There was no improvement in operative strategy errors. Analysis of longitudinal performance of laboratory residents shows higher scores for repeat participants in the category of rule-based errors. These findings suggest that laboratory residents can learn from rule-based mistakes when provided with annual performance-based assessments. This benefit was not seen with operative strategy errors and has important implications for

  8. 42 CFR 493.1453 - Condition: Laboratories performing high complexity testing; clinical consultant.

    Science.gov (United States)

    2010-10-01

    ... Condition: Laboratories performing high complexity testing; clinical consultant. The laboratory must have a... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; clinical consultant. 493.1453 Section 493.1453 Public Health CENTERS FOR MEDICARE & MEDICAID...

  9. Recommended procedures for performance testing of radiobioassay laboratories: Volume 2, In vitro samples

    International Nuclear Information System (INIS)

    Fenrick, H.W.; MacLellan, J.A.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard specifies the criteria for defining the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of in vitro test samples (artificial urine and fecal matter) for indirect bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented. 8 refs., 3 tabs

  10. 42 CFR 493.1415 - Condition: Laboratories performing moderate complexity testing; clinical consultant.

    Science.gov (United States)

    2010-10-01

    ... § 493.1415 Condition: Laboratories performing moderate complexity testing; clinical consultant. The laboratory must have a clinical consultant who meets the qualification requirements of § 493.1417 of this... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing moderate...

  11. The ATLAS project: The effects of a constructionist digital laboratory project on undergraduate laboratory performance.

    Science.gov (United States)

    Shoepe, Todd C; Cavedon, Dana K; Derian, Joseph M; Levy, Celine S; Morales, Amy

    2015-01-01

    Anatomical education is a dynamic field where developments in the implementation of constructive, situated-learning show promise in improving student achievement. The purpose of this study was to examine the effectiveness of an individualized, technology heavy project in promoting student performance in a combined anatomy and physiology laboratory course. Mixed-methods research was used to compare two cohorts of anatomy laboratories separated by the adoption of a new laboratory atlas project, which were defined as preceding (PRE) and following the adoption of the Anatomical Teaching and Learning Assessment Study (ATLAS; POST). The ATLAS project required the creation of a student-generated, photographic atlas via acquisition of specimen images taken with tablet technology and digital microscope cameras throughout the semester. Images were transferred to laptops, digitally labeled and photo edited weekly, and compiled into a digital book using Internet publishing freeware for final project submission. An analysis of covariance confirmed that student final examination scores were improved (P project (PRE, n = 75; POST, n = 90; means ± SE; 74.9 ± 0.9 versus 78.1 ± 0.8, respectively) after controlling for cumulative student grade point average. Analysis of questionnaires collected (n = 68) from the post group suggested students identified with atlas objectives, appreciated the comprehensive value in final examination preparation, and the constructionism involved, but recommended alterations in assignment logistics and the format of the final version. Constructionist, comprehensive term-projects utilizing student-preferred technologies could be used to improve performance toward student learning outcomes. © 2014 American Association of Anatomists.

  12. [External quality assessment in clinical biochemistry laboratories: pilot study in 11 laboratories of Lomé (Togo)].

    Science.gov (United States)

    Kouassi, Kafui; Fétéké, Lochina; Assignon, Selom; Dorkenoo, Ameyo; Napo-Koura, Gado

    2015-01-01

    This study aims to evaluate the performance of a few biochemistry analysis and make recommendations to the place of the stakeholders. It is a cross-sectional study conducted between the October 1(st), 2012 and the July 31, 2013 bearing on the results of 5 common examinations of clinical biochemistry, provided by 11 laboratories volunteers opening in the public and private sectors. These laboratories have analysed during the 3 cycles, 2 levels (medium and high) of serum concentration of urea, glucose, creatinine and serum aminotransferases. The performance of laboratories have been determined from the acceptable limits corresponding to the limits of total errors, defined by the French Society of Clinical Biology (SFBC). A system of internal quality control is implemented by all laboratories and 45% of them participated in international programs of external quality assessment (EQA). The rate of acceptable results for the entire study was of 69%. There was a significant difference (plaboratories engaged in a quality approach and the group with default implementation of the quality approach. Also a significant difference was observed between the laboratories of the central level and those of the peripheral level of our health system (plaboratories remains relatively unsatisfactory. It is important that the Ministry of Health put in place a national program of EQA with mandatory participation.

  13. IPEP: Laboratory performance evaluation reports for management of DOE EM programs

    International Nuclear Information System (INIS)

    Hensley, J.E.; Lindahl, P.C.; Streets, W.E.

    1995-01-01

    Environmental restoration program/project managers at DOE's Office of Environmental Management (EM) are making important decisions based on analytical data generated by contracted laboratories. The Analytical Services Division, EM-263, is developing the Integrated Performance Evaluation Program (IPEP) to assess the performance of those laboratories, based on results from Performance Evaluation (PE) programs. The IPEP reports will be used by the laboratories to foster self-assessment and improvement. In addition, IPEP will produce PE reports for three levels of EM management (Operations/Project Offices, Area Program Offices, and Deputy Assistant Secretary Office). These reports will be used to assess whether contracted analytical laboratories have the capability to produce environmental data of the quality necessary for making environmental restoration and waste management decisions

  14. Association between laboratory capacities and world-cup performance in Nordic combined.

    Science.gov (United States)

    Rasdal, Vegard; Fudel, Ronny; Kocbach, Jan; Moen, Frode; Ettema, Gertjan; Sandbakk, Øyvind

    2017-01-01

    Nordic combined (NC) is an Olympic winter-sport performed as a ski jumping (SJ) event followed by a cross-country (XC) pursuit race employing the skating style. To elucidate the associations between sport-specific laboratory capacities and SJ, XC skiing, and overall NC performance in a world-cup NC event. Twelve international world-cup NC athletes from 8 nations performed laboratory testing one day prior to participating in a world-cup NC event. Squat jumps and SJ imitations (IMIT) were performed on a three-dimensional force plate, whereas XC skiing-specific physiological characteristics were obtained from roller ski skating tests on a treadmill and an all-out double poling (DP) test. Finally, body composition was measured. Laboratory capacities were correlated against performance in SJ, 10-km XC skiing, and overall NC in the world-cup event. Multiple regression analysis was used to determine the best suited laboratory variables for predicting performance. Vertical IMIT velocity together with body-mass provided the best prediction for SJ performance (r2 = 0.70, pjump capacity while minimizing body-mass within the BMI limit set by FIS should be considered in the seasonal training of NC athletes.

  15. Solar Probe Cup: Laboratory Performance

    Science.gov (United States)

    Case, A. W.; Kasper, J. C.; Korreck, K. E.; Stevens, M. L.; Larson, D. E.; Wright, K. H., Jr.; Gallagher, D. L.; Whittlesey, P. L.

    2017-12-01

    The Solar Probe Cup (SPC) is a Faraday Cup instrument that will fly on the Paker Solar Probe (PSP) spacecraft, orbiting the Sun at as close as 9.86 solar radii. The SPC instrument is designed to measure the thermal solar wind plasma (protons, alphas, and electrons) that will be encountered throughout its close encounter with the Sun. Due to the solar wind flow being primarily radial, the SPC instrument is pointed directly at the Sun, resulting in an extreme thermal environment that must be tolerated throughout the primary data collection phase. Laboratory testing has been performed over the past 6 months to demonstrate the instrument's performance relative to its requirements, and to characterize the measurements over the expected thermal range. This presentation will demonstrate the performance of the instrument as measured in the lab, describe the operational configurations planned for flight, and discuss the data products that will be created.

  16. Effect of Using Separate Laboratory and Lecture Courses for Introductory Crop Science on Student Performance.

    Science.gov (United States)

    Wiebold, W. J.; Slaughter, Leon

    1986-01-01

    Reviews a study that examined the effects of laboratories on the grade performance of undergraduates in an introductory crop science course. Results indicated that students enrolled in lecture and laboratory concurrently did not receive higher lecture grades than students enrolled solely in lecture, but did have higher laboratory grades. (ML)

  17. Recommended procedures for performance testing of radiobioassay laboratories: Volume 3, In vivo test phantoms

    International Nuclear Information System (INIS)

    MacLellan, J.A.; Traub, R.J.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard describes the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay performance-testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the draft ANSI N13.30 performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of test phantoms used for calibration of measurement systems for direct bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented

  18. The performance test of NAA laboratory at radionuclide measure with low activity

    International Nuclear Information System (INIS)

    Sri Murniasih; Sukirno

    2016-01-01

    The performance test to measure the I-131 radionuclide activity has been carried out at CAST-NAA laboratory. The purpose of this activity is to know the performance of a laboratory in the testing of low radioactivity sample. The tested sample consists of the form I-131 radionuclide sources shaped thin plastic disk with a certain weight. Evaluation of laboratory performance test results carried out by the organizer of the program test appeal (PTKMR-BATAN). Evaluation results showed that testing of point source of the I-131 radionuclide with comparative method gives a good enough results with errors below 10%. The results of the performance test evaluation are useful as the external quality control to a testing method that is expected in NAA laboratory. (author)

  19. Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia.

    Science.gov (United States)

    Aralica, Merica; Krleza, Jasna Lenicek

    2017-02-15

    Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level.

  20. Performance indicators and decision making for outsourcing public health laboratory services.

    Science.gov (United States)

    Santos, Maria Angelica Borges dos; Moraes, Ricardo Montes de; Passos, Sonia Regina Lambert

    2012-06-01

    To develop performance indicators for outsourcing clinical laboratory services, based on information systems and public administrative records. In the municipality of Rio de Janeiro, Southern Brazil, the public health laboratory network comprised 33 laboratories with automated equipment (but no integrated information system), 90 primary care units (where sample collection was performed) and 983 employees. Information records were obtained from the administrative records of the Budget Information System for Public Health and the Outpatient and Hospital Information System of the Unified Health System. Performance indicators (production, productivity, usage and costs) were generated from data collected routinely from 2006 to 2008. The variations in production, costs and unit prices for tests were analyzed by Laspeyres and Paasche indices, which specifically measure laboratory activity, and by the Consumer Price Index from the Brazilian Institute of Geography and Statistics. A total of 10,359,111 tests were performed in 2008 (10.6% increase over 2006), and the test/employee ratio grew by 8.6%. The costs of supplies, wages and providers increased by 2.3%, 45.4% and 18.3%, respectively. The laboratory tests per visit and hospitalizations increased by 10% and 20%, respectively. The direct costs totaled R$ 63.2 million in 2008, representing an increase of 22.2% in current values during the period analyzed. The direct costs deflated by the Brazilian National Consumer Price Index (9.5% for the period) showed an 11.6% increase in production volumes. The activity-specific volume index, which considers changes in the mix of tests, showed increases of 18.5% in the test price and 3.1% in the production volume. The performance indicators, particularly the specific indices for volume and price of activity, constitute a baseline of performance potential for monitoring private laboratories and contractors. The economic performance indicators demonstrated the need for network

  1. Exploration of task performance tests in a physics laboratory

    Science.gov (United States)

    Liu, Dan; El Turkey, Houssein

    2017-11-01

    In this article, we investigate the implementation of task performance tests in an undergraduate physics laboratory. Two performance tests were carried out over two semesters using the task of building a DC circuit. The first implementation in Spring 2014 had certain concerns such as the privacy of students’ testing and their ‘trial and error’ attempts. These concerns were addressed in Fall 2015 through implementing a second performance test. The second implementation was administered differently but the content of the two tests was the same. We discuss the validity of both implementations and present the correlation (or lack of) between the time that students needed to complete the tests and their grades from a paper-based laboratory assessment method.

  2. Design study of underground facility of the Underground Research Laboratory

    International Nuclear Information System (INIS)

    Hibiya, Keisuke; Akiyoshi, Kenji; Ishizuka, Mineo; Anezaki, Susumu

    1998-03-01

    Geoscientific research program to study deep geological environment has been performed by Power Reactor and Nuclear Fuel Development Corporation (PNC). This research is supported by 'Long-Term Program for Research, Development and Utilization of Nuclear Energy'. An Underground Research Laboratory is planned to be constructed at Shoma-sama Hora in the research area belonging to PNC. A wide range of geoscientific research and development activities which have been previously studied at the Tono Area is planned in the laboratory. The Underground Research Laboratory is consisted of Surface Laboratory and Underground Research Facility located from the surface down to depth between several hundreds and 1,000 meters. Based on the results of design study in last year, the design study performed in this year is to investigate the followings in advance of studies for basic design and practical design: concept, design procedure, design flow and total layout. As a study for the concept of the underground facility, items required for the facility are investigated and factors to design the primary form of the underground facility are extracted. Continuously, design methods for the vault and the underground facility are summarized. Furthermore, design procedures of the extracted factors are summarized and total layout is studied considering the results to be obtained from the laboratory. (author)

  3. Clinical laboratory as an economic model for business performance analysis.

    Science.gov (United States)

    Buljanović, Vikica; Patajac, Hrvoje; Petrovecki, Mladen

    2011-08-15

    To perform SWOT (strengths, weaknesses, opportunities, and threats) analysis of a clinical laboratory as an economic model that may be used to improve business performance of laboratories by removing weaknesses, minimizing threats, and using external opportunities and internal strengths. Impact of possible threats to and weaknesses of the Clinical Laboratory at Našice General County Hospital business performance and use of strengths and opportunities to improve operating profit were simulated using models created on the basis of SWOT analysis results. The operating profit as a measure of profitability of the clinical laboratory was defined as total revenue minus total expenses and presented using a profit and loss account. Changes in the input parameters in the profit and loss account for 2008 were determined using opportunities and potential threats, and economic sensitivity analysis was made by using changes in the key parameters. The profit and loss account and economic sensitivity analysis were tools for quantifying the impact of changes in the revenues and expenses on the business operations of clinical laboratory. Results of simulation models showed that operational profit of €470 723 in 2008 could be reduced to only €21 542 if all possible threats became a reality and current weaknesses remained the same. Also, operational gain could be increased to €535 804 if laboratory strengths and opportunities were utilized. If both the opportunities and threats became a reality, the operational profit would decrease by €384 465. The operational profit of the clinical laboratory could be significantly reduced if all threats became a reality and the current weaknesses remained the same. The operational profit could be increased by utilizing strengths and opportunities as much as possible. This type of modeling may be used to monitor business operations of any clinical laboratory and improve its financial situation by implementing changes in the next fiscal

  4. Transuranics Laboratory, achievements and performance

    International Nuclear Information System (INIS)

    Gasco, C.; Anton, M. P.

    2004-01-01

    The Marine and Aquatic Radioecology Group (MARG) was established in 1985 with the main scope of analysing the consequences of the Palomares accident in the adjacent Mediterranean ecosystem. From then on and up to now , this Group has extended its investigations to other European marine environments, such as the Spanish Mediterranean margin, the Artic and the Atlantic. The main research of long-lived radionuclides (plutonium, americium and Cs-137) determining the orography influence, riverine inputs and their geo-chemical associations. This group is currently accomplishing new challenges on the radioecology field such as the development of techniques for transuranics speciation to determine their geo-chemical association to the main sediment compounds. Natural and anthropogenic radionuclides distribution on salt-marsh areas affected by dry-wet periods is being studied as well as the possibilities of fusing crossed techniques for dating recent sediments (pollen, anthropogenic, ''210 Pb, etc). The Laboratory performance description, the procedures used, calculations, challenges and gaps are described in this report. (Author) 22 refs

  5. Impact of laparoscopic surgery training laboratory on surgeon's performance

    Science.gov (United States)

    Torricelli, Fabio C M; Barbosa, Joao Arthur B A; Marchini, Giovanni S

    2016-01-01

    Minimally invasive surgery has been replacing the open standard technique in several procedures. Similar or even better postoperative outcomes have been described in laparoscopic or robot-assisted procedures when compared to open surgery. Moreover, minimally invasive surgery has been providing less postoperative pain, shorter hospitalization, and thus a faster return to daily activities. However, the learning curve required to obtain laparoscopic expertise has been a barrier in laparoscopic spreading. Laparoscopic surgery training laboratory has been developed to aid surgeons to overcome the challenging learning curve. It may include tutorials, inanimate model skills training (box models and virtual reality simulators), animal laboratory, and operating room observation. Several different laparoscopic courses are available with specific characteristics and goals. Herein, we aim to describe the activities performed in a dry and animal-model training laboratory and to evaluate the impact of different kinds of laparoscopic surgery training courses on surgeon’s performance. Several tasks are performed in dry and animal laboratory to reproduce a real surgery. A short period of training can improve laparoscopic surgical skills, although most of times it is not enough to confer laparoscopic expertise for participants. Nevertheless, this short period of training is able to increase the laparoscopic practice of surgeons in their communities. Full laparoscopic training in medical residence or fellowship programs is the best way of stimulating laparoscopic dissemination. PMID:27933135

  6. The performance assessment of undergraduate students in physics laboratory by using guided inquiry

    Science.gov (United States)

    Mubarok, H.; Lutfiyah, A.; Kholiq, A.; Suprapto, N.; Putri, N. P.

    2018-03-01

    The performance assessment of basic physics experiment among undergraduate physics students which includes three stages: pre-laboratory, conducting experiment and final report was explored in this study. The research used a descriptive quantitative approach by utilizing guidebook of basic physics experiment. The findings showed that (1) the performance of pre-laboratory rate among undergraduate physics students in good category (average score = 77.55), which includes the ability of undergraduate physics students’ theory before they were doing the experiment. (2) The performance of conducting experiment was in good category (average score = 78.33). (3) While the performance of final report was in moderate category (average score = 73.73), with the biggest weakness at how to analyse and to discuss the data and writing the abstract.

  7. Using Performance Assessment Model in Physics Laboratory to Increase Students’ Critical Thinking Disposition

    Science.gov (United States)

    Emiliannur, E.; Hamidah, I.; Zainul, A.; Wulan, A. R.

    2017-09-01

    Performance Assessment Model (PAM) has been developed to represent the physics concepts which able to be devided into five experiments: 1) acceleration due to gravity; 2) Hooke’s law; 3) simple harmonic motion; 4) work-energy concepts; and 5) the law of momentum conservation. The aim of this study was to determine the contribution of PAM in physics laboratory to increase students’ Critical Thinking Disposition (CTD) at senior high school. Subject of the study were 11th grade consist 32 students of a senior high school in Lubuk Sikaping, West Sumatera. The research used one group pretest-postest design. Data was collected through essay test and questionnaire about CTD. Data was analyzed using quantitative way with N-gain value. This study concluded that performance assessmet model effectively increases the N-gain at medium category. It means students’ critical thinking disposition significant increase after implementation of performance assessment model in physics laboratory.

  8. Total error components - isolation of laboratory variation from method performance

    International Nuclear Information System (INIS)

    Bottrell, D.; Bleyler, R.; Fisk, J.; Hiatt, M.

    1992-01-01

    The consideration of total error across sampling and analytical components of environmental measurements is relatively recent. The U.S. Environmental Protection Agency (EPA), through the Contract Laboratory Program (CLP), provides complete analyses and documented reports on approximately 70,000 samples per year. The quality assurance (QA) functions of the CLP procedures provide an ideal data base-CLP Automated Results Data Base (CARD)-to evaluate program performance relative to quality control (QC) criteria and to evaluate the analysis of blind samples. Repetitive analyses of blind samples within each participating laboratory provide a mechanism to separate laboratory and method performance. Isolation of error sources is necessary to identify effective options to establish performance expectations, and to improve procedures. In addition, optimized method performance is necessary to identify significant effects that result from the selection among alternative procedures in the data collection process (e.g., sampling device, storage container, mode of sample transit, etc.). This information is necessary to evaluate data quality; to understand overall quality; and to provide appropriate, cost-effective information required to support a specific decision

  9. Performance audits and laboratory comparisons for SCOS97-NARSTO measurements of speciated volatile organic compounds

    Science.gov (United States)

    Fujita, Eric M.; Harshfield, Gregory; Sheetz, Laurence

    Performance audits and laboratory comparisons were conducted as part of the quality assurance program for the 1997 Southern California Ozone Study (SCOS97-NARSTO) to document potential measurement biases among laboratories measuring speciated nonmethane hydrocarbons (NMHC), carbonyl compounds, halogenated compounds, and biogenic hydrocarbons. The results show that measurements of volatile organic compounds (VOC) made during SCOS97-NARSTO are generally consistent with specified data quality objectives. The hydrocarbon comparison involved nine laboratories and consisted of two sets of collocated ambient samples. The coefficients of variation among laboratories for the sum of the 55 PAM target compounds and total NMHC ranged from ±5 to 15 percent for ambient samples from Los Angeles and Azusa. Abundant hydrocarbons are consistently identified by all laboratories, but discrepancies occur for olefins greater than C 4 and for hydrocarbons greater than C 8. Laboratory comparisons for halogenated compounds and biogenic hydrocarbons consisted of both concurrent ambient sampling by different laboratories and round-robin analysis of ambient samples. The coefficients of variation among participating laboratories were about 10-20 percent. Performance audits were conducted for measurement of carbonyl compounds involving sampling from a standard mixture of carbonyl compounds. The values reported by most of the laboratories were within 10-20 percent of those of the reference laboratory. Results of field measurement comparisons showed larger variations among the laboratories ranging from 20 to 40 percent for C 1-C 3 carbonyl compounds. The greater variations observed in the field measurement comparison may reflect potential sampling artifacts, which the performance audits did not address.

  10. Method to Increase Undergraduate Laboratory Student Confidence in Performing Independent Research

    Directory of Open Access Journals (Sweden)

    Colton E. Kempton

    2017-05-01

    Full Text Available The goal of an undergraduate laboratory course should be not only to introduce the students to biology methodologies and techniques, but also to teach them independent analytical thinking skills and proper experiment design.  This is especially true for advanced biology laboratory courses that undergraduate students typically take as a junior or senior in college.  Many courses achieve the goal of teaching techniques, but fail to approach the larger goal of teaching critical thinking, experimental design, and student independence.  Here we describe a study examining the application of the scaffolding instructional philosophy in which students are taught molecular techniques with decreasing guidance to force the development of analytical thinking skills and prepare undergraduate students for independent laboratory research. This method was applied to our advanced molecular biology laboratory class and resulted in an increase of confidence among the undergraduate students in their abilities to perform independent research.

  11. Association between laboratory capacities and world-cup performance in Nordic combined.

    Directory of Open Access Journals (Sweden)

    Vegard Rasdal

    Full Text Available Nordic combined (NC is an Olympic winter-sport performed as a ski jumping (SJ event followed by a cross-country (XC pursuit race employing the skating style.To elucidate the associations between sport-specific laboratory capacities and SJ, XC skiing, and overall NC performance in a world-cup NC event.Twelve international world-cup NC athletes from 8 nations performed laboratory testing one day prior to participating in a world-cup NC event. Squat jumps and SJ imitations (IMIT were performed on a three-dimensional force plate, whereas XC skiing-specific physiological characteristics were obtained from roller ski skating tests on a treadmill and an all-out double poling (DP test. Finally, body composition was measured. Laboratory capacities were correlated against performance in SJ, 10-km XC skiing, and overall NC in the world-cup event. Multiple regression analysis was used to determine the best suited laboratory variables for predicting performance.Vertical IMIT velocity together with body-mass provided the best prediction for SJ performance (r2 = 0.70, p<0.01, while body-mass-normalized [Formula: see text] and DP power provided the best prediction for XC performance (r2 = 0.68, p<0.05. Body-mass-normalized [Formula: see text] was the only significant correlate with overall NC performance (r2 = 0.43, p<0.05 in this competition.Overall, the concurrent development of [Formula: see text], upper-body power, and SJ-specific vertical jump capacity while minimizing body-mass within the BMI limit set by FIS should be considered in the seasonal training of NC athletes.

  12. Clinical laboratory as an economic model for business performance analysis

    Science.gov (United States)

    Buljanović, Vikica; Patajac, Hrvoje; Petrovečki, Mladen

    2011-01-01

    Aim To perform SWOT (strengths, weaknesses, opportunities, and threats) analysis of a clinical laboratory as an economic model that may be used to improve business performance of laboratories by removing weaknesses, minimizing threats, and using external opportunities and internal strengths. Methods Impact of possible threats to and weaknesses of the Clinical Laboratory at Našice General County Hospital business performance and use of strengths and opportunities to improve operating profit were simulated using models created on the basis of SWOT analysis results. The operating profit as a measure of profitability of the clinical laboratory was defined as total revenue minus total expenses and presented using a profit and loss account. Changes in the input parameters in the profit and loss account for 2008 were determined using opportunities and potential threats, and economic sensitivity analysis was made by using changes in the key parameters. The profit and loss account and economic sensitivity analysis were tools for quantifying the impact of changes in the revenues and expenses on the business operations of clinical laboratory. Results Results of simulation models showed that operational profit of €470 723 in 2008 could be reduced to only €21 542 if all possible threats became a reality and current weaknesses remained the same. Also, operational gain could be increased to €535 804 if laboratory strengths and opportunities were utilized. If both the opportunities and threats became a reality, the operational profit would decrease by €384 465. Conclusion The operational profit of the clinical laboratory could be significantly reduced if all threats became a reality and the current weaknesses remained the same. The operational profit could be increased by utilizing strengths and opportunities as much as possible. This type of modeling may be used to monitor business operations of any clinical laboratory and improve its financial situation by

  13. Laboratory investigation of the performance properties of hot mix asphalt containing waste glass

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph

    2016-07-01

    Full Text Available CSIR is currently undertaking a study on potential utilization of crushed glass as a substitute material to natural aggregate in asphalt mixes. As part of the study, laboratory investigation is needed to determine the performance characteristics...

  14. Radiation protection - Performance criteria for service laboratories performing biological dosimetry by cytogenetics

    International Nuclear Information System (INIS)

    2004-01-01

    This International Standard provides criteria for quality assurance and quality control, evaluation of the performance and the accreditation of biological dosimetry by cytogenetic service laboratories. This International Standard addresses: a) the confidentiality of personal information, for the customer and the service laboratory, b) the laboratory safety requirements, c) the calibration sources and calibration dose ranges useful for establishing the reference dose-effect curves allowing the dose estimation from chromosome aberration frequency, and the minimum detection levels, d) the scoring procedure for unstable chromosome aberrations used for biological dosimetry, e) the criteria for converting a measured aberration frequency into an estimate of absorbed dose, f) the reporting of results, g) the quality assurance and quality control, h) informative annexes containing examples of a questionnaire, instructions for customers, a data sheet for recording aberrations and a sample report

  15. Testing the performance of microbiological safety cabinets used in microbiology laboratories in South Korea.

    Science.gov (United States)

    Hwang, S H; Yi, T W; Cho, K H; Lee, I M; Yoon, C S

    2011-09-01

    To test a performance of the microbiological safety cabinets (MSCs) according to the type of MSCs in microbial laboratories. Tests were carried out to assess the performance of 31 MSCs in 14 different facilities, including six different biological test laboratories in six hospitals and eight different laboratories in three universities. The following tests were performed on the MSCs: the downflow test, intake velocity test, high-efficiency particulate air filter leak test and the airflow smoke pattern test. These performance tests were carried out in accordance with the standard procedures. Only 23% of Class II A1 (8), A2 (19) and unknown MSCs (4) passed these performance tests. The main reasons for the failure of MSCs were inappropriate intake velocity (65%), leakage in the HEPA filter sealing (50%), unbalanced airflow smoke pattern in the cabinets (39%) and inappropriate downflow (27%). This study showed that routine checks of MSCs are important to detect and strengthen the weak spots that frequently develop, as observed during the evaluation of the MSCs of various institutions. Routine evaluation and maintenance of MSCs are critical for optimizing performance. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  16. Association between laboratory capacities and world-cup performance in Nordic combined

    Science.gov (United States)

    Fudel, Ronny; Kocbach, Jan; Moen, Frode; Ettema, Gertjan; Sandbakk, Øyvind

    2017-01-01

    Background Nordic combined (NC) is an Olympic winter-sport performed as a ski jumping (SJ) event followed by a cross-country (XC) pursuit race employing the skating style. Purpose To elucidate the associations between sport-specific laboratory capacities and SJ, XC skiing, and overall NC performance in a world-cup NC event. Methods Twelve international world-cup NC athletes from 8 nations performed laboratory testing one day prior to participating in a world-cup NC event. Squat jumps and SJ imitations (IMIT) were performed on a three-dimensional force plate, whereas XC skiing-specific physiological characteristics were obtained from roller ski skating tests on a treadmill and an all-out double poling (DP) test. Finally, body composition was measured. Laboratory capacities were correlated against performance in SJ, 10-km XC skiing, and overall NC in the world-cup event. Multiple regression analysis was used to determine the best suited laboratory variables for predicting performance. Results Vertical IMIT velocity together with body-mass provided the best prediction for SJ performance (r2 = 0.70, p<0.01), while body-mass-normalized V˙O2peak and DP power provided the best prediction for XC performance (r2 = 0.68, p<0.05). Body-mass-normalized V˙O2peak was the only significant correlate with overall NC performance (r2 = 0.43, p<0.05) in this competition. Conclusion Overall, the concurrent development of V˙O2peak, upper-body power, and SJ-specific vertical jump capacity while minimizing body-mass within the BMI limit set by FIS should be considered in the seasonal training of NC athletes. PMID:28662163

  17. Practice for characterization and performance of a high-dose radiation dosimetry calibration laboratory

    International Nuclear Information System (INIS)

    2003-01-01

    This practice addresses the specific requirements for laboratories engaged in dosimetry calibrations involving ionizing radiation, namely, gamma-radiation, electron beams or X-radiation (bremsstrahlung) beams. It specifically describes the requirements for the characterization and performance criteria to be met by a high-dose radiation dosimetry calibration laboratory. The absorbed-dose range is typically between 10 and 10 5 Gy. This practice addresses criteria for laboratories seeking accreditation for performing high-dose dosimetry calibrations, and is a supplement to the general requirements described in ISO/IEC 17025. By meeting these criteria and those in ISO/IEC 17025, the laboratory may be accredited by a recognized accreditation organization. Adherence to these criteria will help to ensure high standards of performance and instill confidence regarding the competency of the accredited laboratory with respect to the services it offers

  18. A prequalifying program for evaluating the analytical performance of commercial laboratories

    International Nuclear Information System (INIS)

    Reith, C.C.; Bishop, C.T.

    1987-01-01

    Soil and water samples were spiked with known activities of radionuclides and sent to seven commercial laboratories that had expressed an interest in analyzing environmental samples for the Waste Isolation Pilot Plant (WIPP). This Prequalifying Program was part of the selection process for an analytical subcontractor for a three-year program of baseline radiological surveillance around the WIPP site. Both media were spiked at three different activity levels with several transuranic radionuclides, as well as tritium, fission products, and activation products. Laboratory performance was evaluated by calculating relative error for each radionuclide in each sample, assigning grade values, and compiling grades into report cards for each candidate. Results for the five laboratories completing the Prequalifying Program were pooled to reveal differing degrees of difficulty among the treatments and radionuclides. Interlaboratory comparisons revealed systematic errors in the performance of one candidate. The final report cards contained clear differences among overall grades for the five laboratories, enabling analytical performance to be used as a quantitative criterion in the selection of an analytical subcontractor. (author)

  19. Application of Lean-Six Sigma Approach in a Laboratory Experimental Case Study

    Directory of Open Access Journals (Sweden)

    Hashim Raza Rizvi

    2013-12-01

    Full Text Available Laboratory experiments are a conventional activity performed at academic institutions, government and private organizations. These experimental studies provide the basis for new inventions in the field of science and engineering. Laboratory experiments are conducted on the basis of provided guidelines, already established by different standard organizations like ASTM, AASHTO etc. This article is based on a case study in which the process of an experiment is examined on the basis of Value Stream Maps (VSM and potential improvement possibilities have been identified. After determining the potential waste, appropriate Lean tools are selected to implement and observe the improvements. The process is examined after application of the Lean tools and a comparison is performed. University laboratory environment can be improved considerably by applying Lean Tools. MUDA application reduced the total work time from 90.75 hours and 10-CD to 63.75 hours and 7-CD hence saving, 27 hours and 3-CD for one experiment. This is remarkable achievement of this application. Heijunka application provided the students equal workload and they performed explicitly better than they used to. 5-S tool provided the students the opportunity to manage the laboratory in an effective and clean way. Safety of the students is a very major concern at university laboratory environment. 5-S not only upgraded the laboratory overall performance, but it significantly raised the safety standards of the laboratory. More application of the Lean Tools should be exercised explored to have more effective and efficient university laboratory experimental environment.

  20. 7 CFR 98.3 - Analyses performed and locations of laboratories.

    Science.gov (United States)

    2010-01-01

    ... the special laboratory analyses rendered by the Science and Technology as a result of an agreement... Sausage Fat, salt 4 Pork Sausage Fat, moisture 4 Pork Sausage Fat 4 Mil-P-44131A (Pork Steaks, Flaked... performed at any one of the Science and Technology (S&T) field laboratories as follows: (1) USDA, AMS...

  1. Knowledge, attitude, and practice (KAP) of 'teaching laboratory' technicians towards laboratory safety and waste management: a pilot interventional study.

    Science.gov (United States)

    El-Gilany, A-H; El-Shaer, S; Khashaba, E; El-Dakroory, S A; Omar, N

    2017-06-01

    A quasi-experimental study was performed on 20 technicians working in the Faculty of Medicine, Mansoura University, Egypt. The knowledge, attitude, and practice (KAP) of laboratory technicians was measured before and two months after enrolling them in an intervention programme about laboratory best practice procedures. The programme addressed laboratory safety and medical waste management. The assessment was performed using a validated Arabic self-administered questionnaire. Pre- and post-intervention scores were compared using non-parametric tests. There are significant increases in the scores of KAP after implementation of the training programme. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Can current analytical quality performance of UK clinical laboratories support evidence-based guidelines for diabetes and ischaemic heart disease?--A pilot study and a proposal.

    Science.gov (United States)

    Jassam, Nuthar; Yundt-Pacheco, John; Jansen, Rob; Thomas, Annette; Barth, Julian H

    2013-08-01

    The implementation of national and international guidelines is beginning to standardise clinical practice. However, since many guidelines have decision limits based on laboratory tests, there is an urgent need to ensure that different laboratories obtain the same analytical result on any sample. A scientifically-based quality control process will be a pre-requisite to provide this level of analytical performance which will support evidence-based guidelines and movement of patients across boundaries while maintaining standardised outcomes. We discuss the finding of a pilot study performed to assess UK clinical laboratories readiness to work to a higher grade quality specifications such as biological variation-based quality specifications. Internal quality control (IQC) data for HbA1c, glucose, creatinine, cholesterol and high density lipoprotein (HDL)-cholesterol were collected from UK laboratories participating in the Bio-Rad Unity QC programme. The median of the coefficient of variation (CV%) of the participating laboratories was evaluated against the CV% based on biological variation. Except creatinine, the other four analytes had a variable degree of compliance with the biological variation-based quality specifications. More than 75% of the laboratories met the biological variation-based quality specifications for glucose, cholesterol and HDL-cholesterol. Slightly over 50% of the laboratories met the analytical goal for HBA1c. Only one analyte (cholesterol) had a performance achieving the higher quality specifications consistent with 5σ. Our data from IQC do not consistently demonstrate that the results from clinical laboratories meet evidence-based quality specifications. Therefore, we propose that a graded scale of quality specifications may be needed at this stage.

  3. 75 FR 80011 - Good Laboratory Practice for Nonclinical Laboratory Studies

    Science.gov (United States)

    2010-12-21

    .... FDA-2010-N-0548] Good Laboratory Practice for Nonclinical Laboratory Studies AGENCY: Food and Drug... (FDA) is seeking comment on whether to amend the regulations governing good laboratory practices (GLPs..., 1978 (43 FR 60013). As stated in its scope (Sec. 58.1), this regulation prescribes good laboratory...

  4. Expressing analytical performance from multi-sample evaluation in laboratory EQA.

    Science.gov (United States)

    Thelen, Marc H M; Jansen, Rob T P; Weykamp, Cas W; Steigstra, Herman; Meijer, Ron; Cobbaert, Christa M

    2017-08-28

    To provide its participants with an external quality assessment system (EQAS) that can be used to check trueness, the Dutch EQAS organizer, Organization for Quality Assessment of Laboratory Diagnostics (SKML), has innovated its general chemistry scheme over the last decade by introducing fresh frozen commutable samples whose values were assigned by Joint Committee for Traceability in Laboratory Medicine (JCTLM)-listed reference laboratories using reference methods where possible. Here we present some important innovations in our feedback reports that allow participants to judge whether their trueness and imprecision meet predefined analytical performance specifications. Sigma metrics are used to calculate performance indicators named 'sigma values'. Tolerance intervals are based on both Total Error allowable (TEa) according to biological variation data and state of the art (SA) in line with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Milan consensus. The existing SKML feedback reports that express trueness as the agreement between the regression line through the results of the last 12 months and the values obtained from reference laboratories and calculate imprecision from the residuals of the regression line are now enriched with sigma values calculated from the degree to which the combination of trueness and imprecision are within tolerance limits. The information and its conclusion to a simple two-point scoring system are also graphically represented in addition to the existing difference plot. By adding sigma metrics-based performance evaluation in relation to both TEa and SA tolerance intervals to its EQAS schemes, SKML provides its participants with a powerful and actionable check on accuracy.

  5. A comparative study of the systems for neutronics calculations used in Los Alamos Scientific Laboratory (LASL) and Argonne National Laboratory (ANL)

    International Nuclear Information System (INIS)

    Amorim, E.S. do; D'Oliveira, A.B.; Oliveira, E.C. de.

    1980-11-01

    A comparative study of the systems for neutronics calculations used in Los Alamos Scientific Laboratory (LASL) and Argonne National Laboratory (ANL) has been performed using benchmark results available in the literature, in order to analyse tghe convenience of using the respective codes MINX/NJOY and ETOE/MC 2 -2 for performing neutronics calculations in course at the Divisao de Estudos Avancados. (Author) [pt

  6. Improving performance in the ED through laboratory information exchange systems.

    Science.gov (United States)

    Raymond, Louis; Paré, Guy; Maillet, Éric; Ortiz de Guinea, Ana; Trudel, Marie-Claude; Marsan, Josianne

    2018-03-12

    The accessibility of laboratory test results is crucial to the performance of emergency departments and to the safety of patients. This study aims to develop a better understanding of which laboratory information exchange (LIE) systems emergency care physicians (ECPs) are using to consult their patients' laboratory test results and which benefits they derive from such use. A survey of 163 (36%) ECPs in Quebec was conducted in collaboration with the Quebec's Department of Health and Social Services. Descriptive statistics, chi-square tests, cluster analyses, and ANOVAs were conducted. The great majority of respondents indicated that they use several LIE systems including interoperable electronic health record (iEHR) systems, laboratory results viewers (LRVs), and emergency department information systems (EDIS) to consult their patients' laboratory results. Three distinct profiles of LIE users were observed. The extent of LIE usage was found to be primarily determined by the functional design differences between LIE systems available in the EDs. Our findings also indicate that the more widespread LIE usage, the higher the perceived benefits. More specifically, physicians who make extensive use of iEHR systems and LRVs obtain the widest range of benefits in terms of efficiency, quality, and safety of emergency care. Extensive use of LIE systems allows ECPs to better determine and monitor the health status of their patients, verify their diagnostic assumptions, and apply evidence-based practices in laboratory medicine. But for such benefits to be possible, ECPs must be provided with LIE systems that produce accurate, up-to-date, complete, and easy-to-interpret information.

  7. [Quality Management and Quality Specifications of Laboratory Tests in Clinical Studies--Challenges in Pre-Analytical Processes in Clinical Laboratories].

    Science.gov (United States)

    Ishibashi, Midori

    2015-01-01

    The cost, speed, and quality are the three important factors recently indicated by the Ministry of Health, Labour and Welfare (MHLW) for the purpose of accelerating clinical studies. Based on this background, the importance of laboratory tests is increasing, especially in the evaluation of clinical study participants' entry and safety, and drug efficacy. To assure the quality of laboratory tests, providing high-quality laboratory tests is mandatory. For providing adequate quality assurance in laboratory tests, quality control in the three fields of pre-analytical, analytical, and post-analytical processes is extremely important. There are, however, no detailed written requirements concerning specimen collection, handling, preparation, storage, and shipping. Most laboratory tests for clinical studies are performed onsite in a local laboratory; however, a part of laboratory tests is done in offsite central laboratories after specimen shipping. As factors affecting laboratory tests, individual and inter-individual variations are well-known. Besides these factors, standardizing the factors of specimen collection, handling, preparation, storage, and shipping, may improve and maintain the high quality of clinical studies in general. Furthermore, the analytical method, units, and reference interval are also important factors. It is concluded that, to overcome the problems derived from pre-analytical processes, it is necessary to standardize specimen handling in a broad sense.

  8. 222-S LABORATORY FUME HOOD TESTING STUDY

    International Nuclear Information System (INIS)

    RUELAS, B.H.

    2007-01-01

    The 222-S Laboratory contains 155 active fume hoods that are used to support analytical work with radioactive and/or toxic materials. The performance of a fume hood was brought into question after employees detected odors in the work area while mixing chemicals within the subject fume hood. Following the event, testing of the fume hood was conducted to assess the performance of the fume hood. Based on observations from the testing, it was deemed appropriate to conduct performance evaluations of other fume hoods within the laboratory

  9. How do laboratory technicians perceive their role in the tuberculosis diagnostic process? A cross-sectional study among laboratory technicians in health centers of Central Java Province, Indonesia.

    Science.gov (United States)

    Widjanarko, Bagoes; Widyastari, Dyah Anantalia; Martini, Martini; Ginandjar, Praba

    2016-01-01

    Detection of acid-fast bacilli in respiratory specimens serves as an initial pulmonary tuberculosis (TB) diagnosis. Laboratories are the essential and fundamental part of all health systems. This study aimed to describe how laboratory technicians perceived their own self and work. This included perceived self-efficacy, perceived role, perceived equipment availability, perceived procedures, perceived reward and job, and perceived benefit of health education, as well as level of knowledge and attitudes related to work performance of laboratory technicians. This was a cross-sectional quantitative study involving 120 laboratory technicians conducted in Central Java. Interviews and observation were conducted to measure performance and work-related variables. Among 120 laboratory technicians, 43.3% showed fairly good performance. They complied with 50%-75% of all procedures, including sputum collection, laboratory tools utilization, sputum smearing, staining, smear examination, grading of results, and universal precaution practice. Perceived role, perceived self-efficacy, and knowledge of laboratory procedures were significantly correlated to performance, besides education and years of working as a laboratory technician. Perceived equipment availability was also significantly correlated to performance after the education variable was controlled. Most of the laboratory technicians believed that they have an important role in TB patients' treatment and should display proper self-efficacy in performing laboratory activities. The result may serve as a basic consideration to develop a policy for enhancing motivation of laboratory technicians in order to improve the TB control program.

  10. Association Between Endovascular Performance in a Simulated Setting and in the Catheterization Laboratory

    DEFF Research Database (Denmark)

    Räder, Sune B E W; Abildgaard, Ulrik; Jørgensen, Erik

    2014-01-01

    performance in the catheterization laboratory is not linear. The novel rating scale for CA (CARS) seems to be a valid proficiency assessment instrument in the catheterization laboratory. Familiarity with the simulator may overestimate proficiency, which means that simulator performance as a predictor...

  11. ANALYTICAL MICROBIOLOGY LABORATORY

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory contains equipment that performs a broad array of microbiological analyses for pathogenic and spoilage microorganisms. It performs challenge studies...

  12. How do laboratory technicians perceive their role in tuberculosis diagnostic process: a cross-sectional study among laboratory technicians in health centers of Central Java Province, Indonesia

    Directory of Open Access Journals (Sweden)

    Widjanarko B

    2016-09-01

    Full Text Available Bagoes Widjanarko,1 Dyah Anantalia Widyastari,2 Martini Martini,3 Praba Ginandjar3 1Department of Health Education and Behavior Sciences, Faculty of Public Health, Diponegoro University, Semarang, Indonesia; 2Institute for Population and Social Research, Mahidol University, Salaya, Thailand; 3Department of Epidemiology, Faculty of Public Health, Diponegoro University, Semarang, Indonesia Purpose: Detection of acid-fast bacilli in respiratory specimens serves as an initial pulmonary tuberculosis (TB diagnosis. Laboratories are the essential and fundamental part of all health systems. This study aimed to describe how laboratory technicians perceived their own self and work. This included perceived self-efficacy, perceived role, perceived equipment availability, perceived procedures, perceived reward and job, and perceived benefit of health education, as well as level of knowledge and attitudes related to work performance of laboratory technicians.Methods: This was a cross-sectional quantitative study involving 120 laboratory technicians conducted in Central Java. Interviews and observation were conducted to measure performance and work-related variables.Results: Among 120 laboratory technicians, 43.3% showed fairly good performance. They complied with 50%–75% of all procedures, including sputum collection, laboratory tools utilization, sputum smearing, staining, smear examination, grading of results, and universal precaution practice. Perceived role, perceived self-efficacy, and knowledge of laboratory procedures were significantly correlated to performance, besides education and years of working as a laboratory technician. Perceived equipment availability was also significantly correlated to performance after the education variable was controlled.Conclusion: Most of the laboratory technicians believed that they have an important role in TB patients’ treatment and should display proper self-efficacy in performing laboratory activities. The

  13. ANALISIS KEPUASAN PELANGGAN DENGAN IMPORTANCE PERFORMANCE ANALYSIS DI SBU LABORATORY CIBITUNG PT SUCOFINDO (PERSERO

    Directory of Open Access Journals (Sweden)

    Johan Oscar Ong

    2014-01-01

    Full Text Available Kepuasan pelanggan adalah perbandingan antara kinerja yang diharapkan oleh pelanggan dibandingkan dengan kinerja aktual di lapangan. Ketika kinerja aktual lebih tinggi dibandingkan dengan harapan pelanggan maka pelanggan merasakan puas dan sebaliknya. Pada kasus perusahaan jasa, kepuasan pelanggan adalah salah satu faktor penting dalam menciptakan iklim bisnis yang baik, pada contoh kasus ini, SBU Laboratory Cibitung PT Sucofindo (Persero belum maksimal dalam memuaskan hasrat pelanggan, untuk itu perlu dianalisis faktor apa saja yang berpengaruh. Dilihat dari kualitas pelayanan serta aplikasi bauran pemasaran yang meliputi variabel Reliability, Responsiveness, Assurance, Empathy, Tangible, Product Quality, dan Price di SBU Laboratory Cibitung PT Sucofindo (Persero yang dianalisis melalui Importance Performance Analysis (IPA maka dari tiga puluh lima atribut yang termasuk pada tujuh variabel tersebut maka ada dua hal penting yang perlu di improvisasi yaitu mengenai atribut biaya jasa yang ditawarkan PT Sucofindo harus sesuai dengan kualitas dan paket harga yang ditawarkan agar terjangkau/menarik, sedangkan dari analisis gap antara kinerja aktual dan harapan maka dapat diketahui bahwa kinerja SBU Laboratory Cibitung PT Sucofindo (Persero belum ada yang melampaui harapan pelanggan. Kata Kunci : kualitas pelayanan, aplikasi bauran pemasaran, importance performance analysis (IPA, kepuasan pelanggan Abstract Customer satisfaction is comparison between customer's expected performance and actual performance.  When actual performance is higher than customer expectation, customer will be satisfied and vice versa. Case at service companies, customer satisfaction is one of the important factor in creating good climate for business, in this case study, SBU Laboratory Cibitung PT Sucofindo (Persero has not maximized in serving customer needs. Therefore, it needs to be analyzed the factors affecting that matter. From the quality service and the application of

  14. Mindfulness, anxiety, and high-stakes mathematics performance in the laboratory and classroom.

    Science.gov (United States)

    Bellinger, David B; DeCaro, Marci S; Ralston, Patricia A S

    2015-12-01

    Mindfulness enhances emotion regulation and cognitive performance. A mindful approach may be especially beneficial in high-stakes academic testing environments, in which anxious thoughts disrupt cognitive control. The current studies examined whether mindfulness improves the emotional response to anxiety-producing testing situations, freeing working memory resources, and improving performance. In Study 1, we examined performance in a high-pressure laboratory setting. Mindfulness indirectly benefited math performance by reducing the experience of state anxiety. This benefit occurred selectively for problems that required greater working memory resources. Study 2 extended these findings to a calculus course taken by undergraduate engineering majors. Mindfulness indirectly benefited students' performance on high-stakes quizzes and exams by reducing their cognitive test anxiety. Mindfulness did not impact performance on lower-stakes homework assignments. These findings reveal an important mechanism by which mindfulness benefits academic performance, and suggest that mindfulness may help attenuate the negative effects of test anxiety. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Zero-gravity cloud physics laboratory: Candidate experiments definition and preliminary concept studies

    Science.gov (United States)

    Eaton, L. R.; Greco, R. V.; Hollinden, A. B.

    1973-01-01

    The candidate definition studies on the zero-g cloud physics laboratory are covered. This laboratory will be an independent self-contained shuttle sortie payload. Several critical technology areas have been identified and studied to assure proper consideration in terms of engineering requirements for the final design. Areas include chambers, gas and particle generators, environmental controls, motion controls, change controls, observational techniques, and composition controls. This unique laboratory will allow studies to be performed without mechanical, aerodynamics, electrical, or other type techniques to support the object under study. This report also covers the candidate experiment definitions, chambers and experiment classes, laboratory concepts and plans, special supporting studies, early flight opportunities and payload planning data for overall shuttle payload requirements assessments.

  16. Atmospheric cloud physics laboratory project study

    Science.gov (United States)

    Schultz, W. E.; Stephen, L. A.; Usher, L. H.

    1976-01-01

    Engineering studies were performed for the Zero-G Cloud Physics Experiment liquid cooling and air pressure control systems. A total of four concepts for the liquid cooling system was evaluated, two of which were found to closely approach the systems requirements. Thermal insulation requirements, system hardware, and control sensor locations were established. The reservoir sizes and initial temperatures were defined as well as system power requirements. In the study of the pressure control system, fluid analyses by the Atmospheric Cloud Physics Laboratory were performed to determine flow characteristics of various orifice sizes, vacuum pump adequacy, and control systems performance. System parameters predicted in these analyses as a function of time include the following for various orifice sizes: (1) chamber and vacuum pump mass flow rates, (2) the number of valve openings or closures, (3) the maximum cloud chamber pressure deviation from the allowable, and (4) cloud chamber and accumulator pressure.

  17. High-performance laboratories and cleanrooms; TOPICAL

    International Nuclear Information System (INIS)

    Tschudi, William; Sartor, Dale; Mills, Evan; Xu, Tengfang

    2002-01-01

    The California Energy Commission sponsored this roadmap to guide energy efficiency research and deployment for high performance cleanrooms and laboratories. Industries and institutions utilizing these building types (termed high-tech buildings) have played an important part in the vitality of the California economy. This roadmap's key objective to present a multi-year agenda to prioritize and coordinate research efforts. It also addresses delivery mechanisms to get the research products into the market. Because of the importance to the California economy, it is appropriate and important for California to take the lead in assessing the energy efficiency research needs, opportunities, and priorities for this market. In addition to the importance to California's economy, energy demand for this market segment is large and growing (estimated at 9400 GWH for 1996, Mills et al. 1996). With their 24hr. continuous operation, high tech facilities are a major contributor to the peak electrical demand. Laboratories and cleanrooms constitute the high tech building market, and although each building type has its unique features, they are similar in that they are extremely energy intensive, involve special environmental considerations, have very high ventilation requirements, and are subject to regulations-primarily safety driven-that tend to have adverse energy implications. High-tech buildings have largely been overlooked in past energy efficiency research. Many industries and institutions utilize laboratories and cleanrooms. As illustrated, there are many industries operating cleanrooms in California. These include semiconductor manufacturing, semiconductor suppliers, pharmaceutical, biotechnology, disk drive manufacturing, flat panel displays, automotive, aerospace, food, hospitals, medical devices, universities, and federal research facilities

  18. Development of a building performance laboratory for South Africa

    CSIR Research Space (South Africa)

    Parsons, S

    2009-05-01

    Full Text Available The CSIR Building Science and Technology Competence area is currently in the process of establishing a Building Performance Laboratory (BPL). The BPL is aimed at becoming a centre at which the knowledge generation and technology development...

  19. The Influence of Collaborative Learning on Student Attitudes and Performance in an Introductory Chemistry Laboratory

    Science.gov (United States)

    Shibley, Ivan A., Jr.; Zimmaro, Dawn M.

    2002-06-01

    This study was designed to determine the effect of collaborative learning on student attitudes and performance in an introductory chemistry laboratory. Two sections per semester for three semesters were randomly designated as either a control section or an experimental section. Students in the control section performed most labs individually, while those in the experimental section performed all labs in groups of four. Both quantitative and qualitative measures were used to evaluate the impact of collaborative learning on student achievement and attitudes. Grades did not differ between the two sections, indicating that collaborative learning did not affect short-term student achievement. Students seemed to develop a more positive attitude about the laboratory and about chemistry in the collaborative learning sections as judged from their classroom evaluations of the teacher, the course, and the collaborative learning experience. The use of collaborative learning in the laboratory as described in this paper therefore may provide a means of improving student attitudes toward chemistry.

  20. High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory

    Science.gov (United States)

    Frey, Douglas D.; Guo, Hui; Karnik, Nikhila

    2013-01-01

    This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…

  1. Performance indicators for quality in surgical and laboratory services at Muhimbili National Hospital (MNH) in Tanzania.

    Science.gov (United States)

    Mbembati, Naboth A; Mwangu, Mugwira; Muhondwa, Eustace P Y; Leshabari, Melkizedek M

    2008-04-01

    Muhimbili National Hospital (MNH), a teaching and national referral hospital, is undergoing major reforms to improve the quality of health care. We performed a retrospective descriptive study using a set of performance indicators for the surgical and laboratory services of MNH in years 2001 and 2002, to help monitor and evaluate the impact of reforms on the quality of health care during and after the reform process. Hospital records were reviewed and information recorded for planned and postponed operations, laboratory equipment, reagents, laboratory tests and quality assurance programmes. In the year 2001 a total of 4332 non-emergency operations were planned, 3313 operations were performed and 1019 (23.5%) operations were postponed. In the year 2002, 4301 non-emergency operations were planned, 3046 were performed and 1255 (29%) were postponed. The most common reasons for operation postponement were "time-barred", interference by emergency operations, no show of patients and inoperable anaesthetic machines. Equipment problems and supply and staff shortages together accounted for one quarter of postponements. In the laboratory, a lack of equipment prevented some tests, but quality assurance was performed for most tests. Current surgical services at MNH are inadequate; operating theatres require modern, functioning equipment and adequate supplies of consumables to provide satisfactory care.

  2. 42 CFR 493.53 - Notification requirements for laboratories issued a certificate for provider-performed microscopy...

    Science.gov (United States)

    2010-10-01

    ... certificate for provider-performed microscopy (PPM) procedures. 493.53 Section 493.53 Public Health CENTERS... CERTIFICATION LABORATORY REQUIREMENTS Registration Certificate, Certificate for Provider-performed Microscopy... certificate for provider-performed microscopy (PPM) procedures. Laboratories issued a certificate for PPM...

  3. A combined field and laboratory design for assessing the impact of night shift work on police officer operational performance.

    Science.gov (United States)

    Waggoner, Lauren B; Grant, Devon A; Van Dongen, Hans P A; Belenky, Gregory; Vila, Bryan

    2012-11-01

    This study assessed the utility of a combined field and laboratory research design for measuring the impact of consecutive night shift work on the sleepiness, vigilance, and driving performance of police patrol officers. For police patrol officers working their normal night shift duty cycles, simulated driving performance and psychomotor vigilance were measured in a laboratory on two separate occasions: in the morning after the last of five consecutive 10.7-h night shifts, and at the same time in the morning after three consecutive days off duty. Order of participation in conditions was randomized among subjects. Subjects experienced manipulation of sleep schedules due to working night shifts in a real operational environment, but performance testing was conducted under controlled laboratory conditions. N = 29 active-duty police patrol officers (27 male, 2 female; age 37.1 ± 6.3 years) working night shift schedules participated in this study. Simulated driving performance, psychomotor vigilance, and subjective sleepiness were significantly degraded following 5 consecutive night shifts as compared to 3 consecutive days off duty, indicating that active-duty police officers are susceptible to performance degradation as a consequence of working nights. This combined field and laboratory research design succeeded in bridging the gap between the realism of the operational environment and the control of laboratory performance testing, demonstrating that this is a useful approach for addressing the relationship between shift work induced fatigue and critical operational task performance.

  4. Network Performance and Quality of Experience of Remote Access Laboratories

    Directory of Open Access Journals (Sweden)

    Alexander A. Kist

    2012-11-01

    Full Text Available Remote Access Laboratories (RAL have become important learning and teaching tools. This paper presents a performance study that targets a specific remote access architecture implemented within a universities operational environment. This particular RAL system provides globally authenticated and arbitrated remote access to virtualized computers as well as computer controlled hardware experiments. This paper presents system performance results that have been obtained utilizing both a set of automated and human subject tests. Principle objectives of the study were: To gain a better understanding of the nature of network traffic caused by experimental activity usage; to obtain an indication of user expectations of activity performance; and to develop a measure to predict Quality of Experience, based on easily measurable Quality of Service parameters. The study emulates network layer variation of access-bandwidth and round-trip-time of typical usage scenarios and contrasts against user perception results that allow classifying expected user performance. It demonstrates that failure rate is excellent measure of usability, and that round-trip-time predominantly affects user experience. Thin-client and remote desktop architectures are popular to separate the location of users and the actual data processing and use similar structures, hence results of this study to be applied in these application areas as well.

  5. Design of an electronic performance support system for food chemistry laboratory classes

    NARCIS (Netherlands)

    Kolk, van der J.

    2013-01-01

    The design oriented research described in this thesis aims at designing an realizing an electronic performance support system for food chemistry laboratory classes (labEPSS). Four design goals related to food chemistry laboratory classes were identified. Firstly, labEPSS should avoid extraneous

  6. Load Disaggregation Technologies: Real World and Laboratory Performance

    Energy Technology Data Exchange (ETDEWEB)

    Mayhorn, Ebony T.; Sullivan, Greg P.; Petersen, Joseph M.; Butner, Ryan S.; Johnson, Erica M.

    2016-09-28

    Low cost interval metering and communication technology improvements over the past ten years have enabled the maturity of load disaggregation (or non-intrusive load monitoring) technologies to better estimate and report energy consumption of individual end-use loads. With the appropriate performance characteristics, these technologies have the potential to enable many utility and customer facing applications such as billing transparency, itemized demand and energy consumption, appliance diagnostics, commissioning, energy efficiency savings verification, load shape research, and demand response measurement. However, there has been much skepticism concerning the ability of load disaggregation products to accurately identify and estimate energy consumption of end-uses; which has hindered wide-spread market adoption. A contributing factor is that common test methods and metrics are not available to evaluate performance without having to perform large scale field demonstrations and pilots, which can be costly when developing such products. Without common and cost-effective methods of evaluation, more developed disaggregation technologies will continue to be slow to market and potential users will remain uncertain about their capabilities. This paper reviews recent field studies and laboratory tests of disaggregation technologies. Several factors are identified that are important to consider in test protocols, so that the results reflect real world performance. Potential metrics are examined to highlight their effectiveness in quantifying disaggregation performance. This analysis is then used to suggest performance metrics that are meaningful and of value to potential users and that will enable researchers/developers to identify beneficial ways to improve their technologies.

  7. The effect of slightly warm temperature on work performance and comfort in open-plan offices - a laboratory study.

    Science.gov (United States)

    Maula, H; Hongisto, V; Östman, L; Haapakangas, A; Koskela, H; Hyönä, J

    2016-04-01

    The aim of the study was to determine the effect of a temperature of 29°C on performance in tasks involving different cognitive demands and to assess the effect on perceived performance, subjective workload, thermal comfort, perceived working conditions, cognitive fatigue, and somatic symptoms in a laboratory with realistic office environment. A comparison was made with a temperature of 23°C. Performance was measured on the basis of six different tasks that reflect different stages of cognitive performance. Thirty-three students participated in the experiment. The exposure time was 3.5 h in both thermal conditions. Performance was negatively affected by slightly warm temperature in the N-back working memory task. Temperature had no effect on performance in other tasks focusing on psychomotor, working memory, attention, or long-term memory capabilities. Temperature had no effect on perceived performance. However, slightly warm temperature caused concentration difficulties. Throat symptoms were found to increase over time at 29°C, but no temporal change was seen at 23°C. No effect of temperature on other symptoms was found. As expected, the differences in thermal comfort were significant. Women perceived a temperature of 23°C colder than men. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Critical appraisal of the Vienna consensus: performance indicators for assisted reproductive technology laboratories.

    Science.gov (United States)

    Lopez-Regalado, María Luisa; Martínez-Granados, Luis; González-Utor, Antonio; Ortiz, Nereyda; Iglesias, Miriam; Ardoy, Manuel; Castilla, Jose A

    2018-05-24

    The Vienna consensus, based on the recommendations of an expert panel, has identified 19 performance indicators for assisted reproductive technology (ART) laboratories. Two levels of reference values are established for these performance indicators: competence and benchmark. For over 10 years, the Spanish embryology association (ASEBIR) has participated in the definition and design of ART performance indicators, seeking to establish specific guidelines for ART laboratories to enhance quality, safety and patient welfare. Four years ago, ASEBIR took part in an initiative by AENOR, the Spanish Association for Standardization and Certification, to develop a national standard in this field (UNE 17900:2013 System of quality management for assisted reproduction laboratories), extending the former requirements, based on ISO 9001, to include performance indicators. Considering the experience acquired, we discuss various aspects of the Vienna consensus and consider certain discrepancies in performance indicators between the consensus and UNE 179007:2013, and analyse the definitions, methodology and reference values used. Copyright © 2018. Published by Elsevier Ltd.

  9. Exploring students' perceptions and performance on predict-observe-explain tasks in high school chemistry laboratory

    Science.gov (United States)

    Vadapally, Praveen

    This study sought to understand the impact of gender and reasoning level on students' perceptions and performances of Predict-Observe-Explain (POE) laboratory tasks in a high school chemistry laboratory. Several literature reviews have reported that students at all levels have not developed the specific knowledge and skills that were expected from their laboratory work. Studies conducted over the last several decades have found that boys tend to be more successful than girls in science and mathematics courses. However, some recent studies have suggested that girls may be reducing this gender gap. This gender difference is the focal point of this research study, which was conducted at a mid-western, rural high school. The participants were 24 boys and 25 girls enrolled in two physical science classes taught by the same teacher. In this mixed methods study, qualitative and quantitative methods were implemented simultaneously over the entire period of the study. MANOVA statistics revealed significant effects due to gender and level of reasoning on the outcome variables, which were POE performances and perceptions of the chemistry laboratory environment. There were no significant interactions between these effects. For the qualitative method, IRB-approved information was collected, coded, grouped, and analyzed. This method was used to derive themes from students' responses on questionnaires and semi-structured interviews. Students with different levels of reasoning and gender were interviewed, and many of them expressed positive themes, which was a clear indication that they had enjoyed participating in the POE learning tasks and they had developed positive perceptions towards POE inquiry laboratory learning environment. When students are capable of formal reasoning, they can use an abstract scientific concept effectively and then relate it to the ideas they generate in their minds. Thus, instructors should factor the nature of students' thinking abilities into their

  10. Laboratory Performance Evaluation of High Modulus Asphalt Concrete Modified with Different Additives

    Directory of Open Access Journals (Sweden)

    Peng Li

    2017-01-01

    Full Text Available The objective of this study is to evaluate comprehensive performance of high modulus asphalt concrete (HMAC and propose common values for establishing evaluation system. Three gradations with different modifiers were conducted to study the high and low temperature performance, shearing behavior, and water stability. The laboratory tests for HMAC included static and dynamic modulus tests, rutting test, uniaxial penetration test, bending test, and immersion Marshall test. Dynamic modulus test results showed that modifier can improve the static modulus and the improvements were remarkable at higher temperature. Moreover, modulus of HMAC-20 was better than those of HMAC-16 and HMAC-25. The results of performance test indicated that HMAC has good performance to resist high temperature rutting, and the resistances of the HMAC-20 and HMAC-25 against rutting were better than that of HMAC-16. Then, the common values of dynamic stability were recommended. Furthermore, common values of HMAC performance were established based on pavement performance tests.

  11. Chemical oil-spill dispersants: evaluation of three laboratory procedures for estimating performance

    International Nuclear Information System (INIS)

    Clayton, J.R.; Marsden, P.

    1992-09-01

    The report presents data from studies designed to evaluate characteristics of selected bench-scale test methods for estimating performance of chemical agents for dispersing oil from surface slicks into an underlying water column. In order to mitigate the effect of surface slicks with chemical dispersant agents, however, an on-scene coordinator must have information and an understanding of performance characteristics for available dispersant agents. Performance of candidate dispersant agents can be estimated on the basis of laboratory testing procedures that are designed to evaluate performance of different agents. Data presented in the report assist in the evaluation of candidate test methods for estimating performance of candidate dispersant agents. Three test methods were selected for evaluating performance: the currently accepted Revised Standard EPA test, Environmental Canada's Swirling Flask test, and the IFP-Dilution test

  12. Improving Gas Furnace Performance: A Field and Laboratory Study at End of Life

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L. [Gas Technology Inst., Des Plaines, IL (United States); Yee, S. [Gas Technology Inst., Des Plaines, IL (United States); Baker, J. [Gas Technology Inst., Des Plaines, IL (United States)

    2015-02-01

    In 2010, natural gas provided 54% of total residential space heating energy the U.S. on a source basis, or 3.5 Quadrillion Btu. Natural gas burned in furnaces accounted for 92% of that total, and boilers and other equipment made up the remainder. A better understanding of installed furnace performance is a key to energy savings for this significant energy usage. Natural gas furnace performance can be measured in many ways. The annual fuel utilization efficiency (AFUE) rating provides a fixed value under specified conditions, akin to the EPA miles per gallon rating for new vehicles. The AFUE rating is provided by the manufacturer to the consumer and is a way to choose between models tested on the same basis. This value is commonly used in energy modeling calculations. ASHRAE 103 is a consensus furnace testing standard developed by the engineering community. The procedure provided in the standard covers heat-up, cool down, condensate heat loss, and steady-state conditions and an imposed oversize factor. The procedure can be used to evaluate furnace performance with specified conditions or with some variation chosen by the tester. In this report the ASHRAE 103 test result will be referred to as Annualized Efficiency (AE) to avoid confusion, and any non-standard test conditions will be noted. Aside from these two laboratory tests, steady state or flue loss efficiency can be measured in the field under many conditions; typically as found or tuned to the manufacturers recommended settings. In this report, AE and steady-state efficiency will be used as measures of furnace performance.

  13. Improving Gas Furnace Performance: A Field and Laboratory Study at End of Life

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L. [Partnership for Advanced Residential Retrofit (PARR), Des Plaines, IL (United States); Yee, S. [Partnership for Advanced Residential Retrofit (PARR), Des Plaines, IL (United States); Baker, J. [Partnership for Advanced Residential Retrofit (PARR), Des Plaines, IL (United States)

    2015-02-01

    In 2010, natural gas provided 54% of total residential space heating energy the U.S. on a source basis, or 3.5 Quadrillion Btu. Natural gas burned in furnaces accounted for 92% of that total, and boilers and other equipment made up the remainder. A better understanding of installed furnace performance is a key to energy savings for this significant energy usage. In this project, the U.S. Department of Energy Building America team Partnership for Advanced Residential Retrofit examined the impact that common installation practices and age-induced equipment degradation may have on the installed performance of natural gas furnaces over the life of the product, as measured by steady-state efficiency and annual efficiency. The team identified 12 furnaces of various ages and efficiencies that were operating in residential homes in the Des Moines, Iowa, metropolitan area and worked with a local heating, ventilation, and air conditioning contractor to retrieve furnaces and test them at the Gas Technology Institute laboratory for steady-state efficiency and annual efficiency. Prior to removal, system airflow, static pressure, equipment temperature rise, and flue loss measurements were recorded for each furnace as installed in the house.

  14. Laboratory performance of sweat conductivity for the screening of cystic fibrosis.

    Science.gov (United States)

    Greaves, Ronda F; Jolly, Lisa; Massie, John; Scott, Sue; Wiley, Veronica C; Metz, Michael P; Mackay, Richard J

    2018-03-28

    There are several complementary English-language guidelines for the performance of the sweat chloride test. These guidelines also incorporate information for the collection of conductivity samples. However, recommendations for the measurement and reporting of sweat conductivity are less clear than for sweat chloride. The aim of the study was to develop an understanding of the testing and reporting practices of sweat conductivity in Australasian laboratories. A survey specifically directed at conductivity testing was sent to the 12 laboratories registered with the Royal College of Pathologists of Australasia Quality Assurance Programs. Nine (75%) laboratories participated in the survey, seven of whom used Wescor Macroduct® for collecting sweat and the Wescor SWEAT·CHEK™ for conductivity testing, and the remaining two used the Wescor Nanoduct®. There was considerable variation in frequency and staffing for this test. Likewise, criteria about which patients it was inappropriate to test, definitions of adequate collection sweat rate, cutoffs and actions recommended on the basis of the result showed variations between laboratories. Variations in sweat conductivity testing and reporting reflect many of the same issues that were revealed in sweat chloride test audits and have the potential to lead to uncertainty about the result and the proper action in response to the result. We recommend that sweat testing guidelines should include clearer statements about the use of sweat conductivity.

  15. Performance of IPEN/CNEN-SP Neutron Activation Analysis Laboratory for microelement determinations in proficiency testing

    International Nuclear Information System (INIS)

    Armelin, Maria Jose A.; Saiki, Mitiko; Souza, Gilberto B. de; Nogueira, Ana Rita A.

    2009-01-01

    The performance of Neutron Activation Laboratory, IPEN - CNEN/SP, was evaluated for the Ca, Fe, K, Mn, Na and Zn determinations in animal feed samples for ruminants through a proficiency test (PT) program. This PT program is organized by EMBRAPA Cattle Southeast to evaluate laboratories that analyze animal feed samples. Considering the fractions of satisfactory z-scores (%) of evaluated analytes to determine the laboratories performance, the general performance indicator obtained by IPEN - CNEN/SP ranged from 90 to 95% of the satisfactory results during the period of participation in the evaluation, four years. (author)

  16. External quality assurance performance of clinical research laboratories in sub-saharan Africa.

    Science.gov (United States)

    Amukele, Timothy K; Michael, Kurt; Hanes, Mary; Miller, Robert E; Jackson, J Brooks

    2012-11-01

    Patient Safety Monitoring in International Laboratories (JHU-SMILE) is a resource at Johns Hopkins University that supports and monitors laboratories in National Institutes of Health-funded international clinical trials. To determine the impact of the JHU-SMILE quality assurance scheme in sub-Saharan African laboratories, we reviewed 40 to 60 months of external quality assurance (EQA) results of the College of American Pathologists (CAP) in these laboratories. We reviewed the performance of 8 analytes: albumin, alanine aminotransferase, creatinine, sodium, WBC, hemoglobin, hematocrit, and the human immunodeficiency virus antibody rapid test. Over the 40- to 60-month observation period, the sub-Saharan laboratories had a 1.63% failure rate, which was 40% lower than the 2011 CAP-wide rate of 2.8%. Seventy-six percent of the observed EQA failures occurred in 4 of the 21 laboratories. These results demonstrate that a system of remote monitoring, feedback, and audits can support quality in low-resource settings, even in places without strong regulatory support for laboratory quality.

  17. Performance of the Brazilian laboratories on radionuclide analysis in environmental samples

    International Nuclear Information System (INIS)

    Vianna, Maria Elizabeth; Tauhata, Luiz; Oliveira, Josue P.; Oliveira, Antonio E.; Clain, Almir F.; Garcia, Luiz Carlos; Conceicao, Cirilo C. da

    1995-01-01

    The performance of fifteen Brazilian environmental radioanalytical laboratories was evaluated after their participation in nine intercomparison runs of the National Intercomparison Program, PNI, offered by the Instituto de Radioprotecao e Dosimetria, CNEN. A total of 549 radionuclide determinations in environmental samples were evaluated. The results classified as Good ranged from 56.4% for Alpha and Beta Gross determinations up to 84.9% for Gamma spectrometry determinations. These results shows that the best performance in radionuclide determination is reached in gamma spectrometry analyses and the worst in Alpha and Beta Gross determinations. This general behavior is similar to the one reached by other laboratories in international intercomparison programs. (author). 1 ref., 1 fig., 1 tab

  18. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Science.gov (United States)

    2010-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  19. Inquiry-based laboratory investigations and student performance on standardized tests in biological science

    Science.gov (United States)

    Patke, Usha

    Achievement data from the 3rd International Mathematics and Sciences Study and Program for International Student Assessment in science have indicated that Black students from economically disadvantaged families underachieve at alarming rates in comparison to White and economically advantaged peer groups. The study site was a predominately Black, urban school district experiencing underachievement. The purpose of this correlational study was to examine the relationship between students' use of inquiry-based laboratory investigations and their performance on the Biology End of Course Test, as well as to examine the relationship while partialling out the effects of student gender. Constructivist theory formed the theoretical foundation of the study. Students' perceived levels of experience with inquiry-based laboratory investigations were measured using the Laboratory Program Variable Inventory (LPVI) survey. LPVI scores of 256 students were correlated with test scores and were examined by student gender. The Pearson correlation coefficient revealed a small direct correlation between students' experience in inquiry-based laboratory investigation classes and standardized test scores on the Biology EOCT. A partial correlational analysis indicated that the correlation remained after controlling for gender. This study may prompt a change from teacher-centered to student-centered pedagogy at the local site in order to increase academic achievement for all students. The results of this study may also influence administrators and policy makers to initiate local, state, or nationwide curricular development. A change in curriculum may promote social change as students become more competent, and more able, to succeed in life beyond secondary school.

  20. Sigma metrics as a tool for evaluating the performance of internal quality control in a clinical chemistry laboratory.

    Science.gov (United States)

    Kumar, B Vinodh; Mohan, Thuthi

    2018-01-01

    Six Sigma is one of the most popular quality management system tools employed for process improvement. The Six Sigma methods are usually applied when the outcome of the process can be measured. This study was done to assess the performance of individual biochemical parameters on a Sigma Scale by calculating the sigma metrics for individual parameters and to follow the Westgard guidelines for appropriate Westgard rules and levels of internal quality control (IQC) that needs to be processed to improve target analyte performance based on the sigma metrics. This is a retrospective study, and data required for the study were extracted between July 2015 and June 2016 from a Secondary Care Government Hospital, Chennai. The data obtained for the study are IQC - coefficient of variation percentage and External Quality Assurance Scheme (EQAS) - Bias% for 16 biochemical parameters. For the level 1 IQC, four analytes (alkaline phosphatase, magnesium, triglyceride, and high-density lipoprotein-cholesterol) showed an ideal performance of ≥6 sigma level, five analytes (urea, total bilirubin, albumin, cholesterol, and potassium) showed an average performance of sigma level and for level 2 IQCs, same four analytes of level 1 showed a performance of ≥6 sigma level, and four analytes (urea, albumin, cholesterol, and potassium) showed an average performance of sigma level. For all analytes sigma level, the quality goal index (QGI) was 1.2 indicated inaccuracy. This study shows that sigma metrics is a good quality tool to assess the analytical performance of a clinical chemistry laboratory. Thus, sigma metric analysis provides a benchmark for the laboratory to design a protocol for IQC, address poor assay performance, and assess the efficiency of existing laboratory processes.

  1. Idaho National Laboratory Quarterly Performance Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Lisbeth [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-11-01

    This report is published quarterly by the Idaho National Laboratory (INL) Quality and Performance Management Organization. The Department of Energy (DOE) Occurrence Reporting and Processing System (ORPS), as prescribed in DOE Order 232.2, “Occurrence Reporting and Processing of Operations Information,” requires a quarterly analysis of events, both reportable and not reportable, for the previous 12 months. This report is the analysis of 60 reportable events (23 from the 4th Qtr FY14 and 37 from the prior three reporting quarters) as well as 58 other issue reports (including not reportable events and Significant Category A and B conditions) identified at INL from July 2013 through October 2014. Battelle Energy Alliance (BEA) operates the INL under contract DE AC07 051D14517.

  2. An approach to quality and performance control in a computer-assisted clinical chemistry laboratory.

    Science.gov (United States)

    Undrill, P E; Frazer, S C

    1979-01-01

    A locally developed, computer-based clinical chemistry laboratory system has been in operation since 1970. This utilises a Digital Equipment Co Ltd PDP 12 and an interconnected PDP 8/F computer. Details are presented of the performance and quality control techniques incorporated into the system. Laboratory performance is assessed through analysis of results from fixed-level control sera as well as from cumulative sum methods. At a simple level the presentation may be considered purely indicative, while at a more sophisticated level statistical concepts have been introduced to aid the laboratory controller in decision-making processes. PMID:438340

  3. [Quality assessment of microscopic examination in tuberculosis diagnostic laboratories: a preliminary study].

    Science.gov (United States)

    Simşek, Hülya; Ceyhan, Ismail; Tarhan, Gülnur; Güner, Uğur

    2010-10-01

    Recently, the diagnosis of pulmonary tuberculosis (TB) has based on smear microscopy in the Direct Observed Treatment Strategy (DOTS) programme which provides the basis of treatment worldwide. Microscopic detection of AFB (Acid-Fast Bacilli) is one of the main components in the National TB Control Programmes (NTCP). Precision level in microscopy procedures and evaluations are the most important steps for accurate diagnosis of the disease and to initiate proper treatment. Therefore, the external quality assessment (EQA) is the most important implement to provide the reliability and validity of tests. In countries where NTCP are performed, this task is fulfilled by the National Reference Laboratories (NRL) according to the guidelines of the World Health Organization (WHO). For this purpose a pilot study was initiated by the central NRL of Turkey for EQA of AFB smear microscopy as part of the NTCP on January 1, 2005. A total of 5 laboratories of which 2 were district TB laboratories (A, B), 2 were tuberculosis control dispensaries (C, D), 1 was a national reference laboratory (E), participated in this study. Blind re-checking method (re-examination of randomly selected slides) was used for the evaluation, and the slides were sent to the central NRL with 3 months interval, four times a year, selected according to LQAS (Lot Quality Assurance Sampling) guides. In the re-evaluation of the slides, false positivity (FP), false negativity (FN) and quantification errors (QE) were noted. Laboratory A, sent totally 525 slides between January 1, 2005 and April 1, 2008. In the result of re-checking, 514 (97.9%) slides were found concordant, and 11 (2.1%) were discordant (10 FP, 1 FN). Laboratory B, participated in the study between October 1, 2005 and July 1, 2006 and of the 67 re-examined slides, 60 (89.5%) were concordant and 7 (10.5%) were discordant (2 FP, 0 FN, 5 QE). Laboratory C, sent 235 slides between January 1, 2005 and April 1, 2006; of them 218 (92.8%) were detected

  4. Laboratory Studies Of Circumstellar Carbonaceous Grain Formation

    Science.gov (United States)

    Contreras, Cesar; Sciamma-O'Brien, Ella; Salama, Farid

    2014-06-01

    The study of the formation processes of dust is essential to understand the budget of extraterrestrial organic molecules. Although dust with all its components plays an important role in the evolution of interstellar (IS) chemistry and in the formation of organic molecules, little is known on the formation processes of carbonaceous dust. We report the progress that was recently achieved in this domain using NASA Ames’ COSmIC facility (Contreras & Salama 2013, ApJS, 208, 6). PAHs are important chemical building blocks of IS dust. They are detected in IDPs and in meteoritic samples. Additionally, observational, laboratory, and theoretical studies have shown that PAHs are an important, ubiquitous component of the ISM. The formation of PAHs from smaller molecules has not been extensively studied. Therefore, we have performed laboratory experiments to study the dynamic processes of carbon grain formation, starting from the smallest hydrocarbon molecules into the formation of larger PAH and further into nanograins. Studies of IS dust analogs formed from a variety of PAH and hydrocarbon precursors as well as species that include the atoms O, N, and S, have recently been performed in our laboratory using the COSmIC facility to provide conditions that simulate IS and circumstellar environments. The species formed in the COSmiC chamber through a pulsed discharge nozzle plasma source are detected and characterized with a cavity ringdown spectrometer coupled to a time-of-flight mass spectrometer, thus providing both spectroscopic and ion mass information in-situ. Analysis of solid soot particles was also conducted using scanning electron microscopy at the UCSC/NASA Ames’ MACS facility. The SEM analysis of the deposition of soot from methane and acetylene precursors seeded in argon plasmas provide examples on the types of nanoparticles and micrograins that are produced in these gas mixtures under our experimental conditions. From these measurements, we derive information on

  5. Key Performance Indicators to Measure Improvement After Implementation of Total Laboratory Automation Abbott Accelerator a3600.

    Science.gov (United States)

    Miler, Marijana; Nikolac Gabaj, Nora; Dukic, Lora; Simundic, Ana-Maria

    2017-12-27

    The aim of the study was to estimate improvement of work efficiency in the laboratory after implementation of total laboratory automation (TLA) by Abbott Accelerator a3600 in the laboratory with measuring different key performance indicators (KPIs) before and after TLA implementation. The objective was also to recommend steps for defining KPIs in other laboratories. For evaluation of improvement 10 organizational and/or technical KPIs were defined for all phases of laboratory work and measured before (November 2013) and after (from 2015 to 2017) TLA implementation. Out of 10 defined KPIs, 9 were successfully measured and significantly improved. Waiting time for registration of samples in the LIS was significantly reduced from 16 (9-28) to 9 (6-16) minutes after TLA (P performed at core biochemistry analyzers which significantly reduced walking distance for sample management (for more than 800 m per worker) and number of tube touches (for almost 50%). Analyzers downtime and engagement time for analyzers maintenance was reduced for 50 h and 28 h per month, respectively. TLA eliminated manual dilution of samples with extreme results with sigma values increment from 3.4 to >6 after TLA. Although median turnaround time TAT for potassium and troponin was higher (for approximately 20 min), number of outliers with TAT >60 min expressed as sigma values were satisfying (>3). Implementation of the TLA improved the most of the processes in our laboratory with 9 out of 10 properly defined and measured KPIs. With proper planning and defining of KPIs, every laboratory could measure changes in daily workflow.

  6. Performance of health laboratories in provision of HIV diagnostic and supportive services in selected districts of Tanzania.

    Science.gov (United States)

    Ishengoma, Deus S; Kamugisha, Mathias L; Rutta, Acleus S M; Kagaruki, Gibson B; Kilale, Andrew M; Kahwa, Amos; Kamugisha, Erasmus; Baraka, Vito; Mandara, Celine I; Materu, Godlisten S; Massaga, Julius J; Magesa, Stephen M; Lemnge, Martha M; Mboera, Leonard E G

    2017-01-23

    Roll-out and implementation of antiretroviral therapy (ART) necessitated many countries in Sub-Saharan Africa to strengthen their national health laboratory systems (NHLSs) to provide high quality HIV diagnostic and supportive services. This study was conducted to assess the performance of health laboratories in provision of HIV diagnostic and supportive services in eight districts (from four regions of Iringa, Mtwara, Tabora and Tanga), after nine years of implementation of HIV/AIDS care and treatment plan in Tanzania. In this cross-sectional study, checklists and observations were utilized to collect information from health facilities (HFs) with care and treatment centres (CTCs) for HIV/AIDS patients; on availability of laboratories, CTCs, laboratory personnel, equipment and reagents. A checklist was also used to collect information on implementation of quality assurance (QA) systems at all levels of the NHLS in the study areas. The four regions had 354 HFs (13 hospitals, 41 Health Centres (HCs) and 300 dispensaries); whereby all hospitals had laboratories and 11 had CTCs while 97.5 and 61.0% of HCs had both laboratories and CTCs, respectively. Of the dispensaries, 36.0 and 15.0% had laboratories and CTCs (mainly in urban areas). Thirty nine HFs (12 hospitals, 21 HCs and six dispensaries) were assessed and 56.4% were located in urban areas. The assessed HFs had 199 laboratory staff of different cadres (laboratory assistants = 35.7%; technicians =32.7%; attendants = 22.6%; and others = 9.1%); with >61% of the staff and 72.3% of the technicians working in urban areas. All laboratories were using rapid diagnostic tests for HIV testing. Over 74% of the laboratories were performing internal quality control and 51.4% were participating in external QA programmes. Regional and district laboratories had all key equipment and harmonization was maintained for Fluorescence-Activated Cell Sorting (FACS) machines. Most of the biochemical (58.0%) and haematological

  7. Laboratory- and field-based testing as predictors of skating performance in competitive-level female ice hockey.

    Science.gov (United States)

    Henriksson, Tommy; Vescovi, Jason D; Fjellman-Wiklund, Anncristine; Gilenstam, Kajsa

    2016-01-01

    The purpose of this study was to examine whether field-based and/or laboratory-based assessments are valid tools for predicting key performance characteristics of skating in competitive-level female hockey players. Cross-sectional study. Twenty-three female ice hockey players aged 15-25 years (body mass: 66.1±6.3 kg; height: 169.5±5.5 cm), with 10.6±3.2 years playing experience volunteered to participate in the study. The field-based assessments included 20 m sprint, squat jump, countermovement jump, 30-second repeated jump test, standing long jump, single-leg standing long jump, 20 m shuttle run test, isometric leg pull, one-repetition maximum bench press, and one-repetition maximum squats. The laboratory-based assessments included body composition (dual energy X-ray absorptiometry), maximal aerobic power, and isokinetic strength (Biodex). The on-ice tests included agility cornering s-turn, cone agility skate, transition agility skate, and modified repeat skate sprint. Data were analyzed using stepwise multivariate linear regression analysis. Linear regression analysis was used to establish the relationship between key performance characteristics of skating and the predictor variables. Regression models (adj R (2)) for the on-ice variables ranged from 0.244 to 0.663 for the field-based assessments and from 0.136 to 0.420 for the laboratory-based assessments. Single-leg tests were the strongest predictors for key performance characteristics of skating. Single leg standing long jump alone explained 57.1%, 38.1%, and 29.1% of the variance in skating time during transition agility skate, agility cornering s-turn, and modified repeat skate sprint, respectively. Isokinetic peak torque in the quadriceps at 90° explained 42.0% and 32.2% of the variance in skating time during agility cornering s-turn and modified repeat skate sprint, respectively. Field-based assessments, particularly single-leg tests, are an adequate substitute to more expensive and time

  8. Hydrogen Field Test Standard: Laboratory and Field Performance

    Science.gov (United States)

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are

  9. Guidance for laboratories performing molecular pathology for cancer patients

    Science.gov (United States)

    Cree, Ian A; Deans, Zandra; Ligtenberg, Marjolijn J L; Normanno, Nicola; Edsjö, Anders; Rouleau, Etienne; Solé, Francesc; Thunnissen, Erik; Timens, Wim; Schuuring, Ed; Dequeker, Elisabeth; Murray, Samuel; Dietel, Manfred; Groenen, Patricia; Van Krieken, J Han

    2014-01-01

    Molecular testing is becoming an important part of the diagnosis of any patient with cancer. The challenge to laboratories is to meet this need, using reliable methods and processes to ensure that patients receive a timely and accurate report on which their treatment will be based. The aim of this paper is to provide minimum requirements for the management of molecular pathology laboratories. This general guidance should be augmented by the specific guidance available for different tumour types and tests. Preanalytical considerations are important, and careful consideration of the way in which specimens are obtained and reach the laboratory is necessary. Sample receipt and handling follow standard operating procedures, but some alterations may be necessary if molecular testing is to be performed, for instance to control tissue fixation. DNA and RNA extraction can be standardised and should be checked for quality and quantity of output on a regular basis. The choice of analytical method(s) depends on clinical requirements, desired turnaround time, and expertise available. Internal quality control, regular internal audit of the whole testing process, laboratory accreditation, and continual participation in external quality assessment schemes are prerequisites for delivery of a reliable service. A molecular pathology report should accurately convey the information the clinician needs to treat the patient with sufficient information to allow for correct interpretation of the result. Molecular pathology is developing rapidly, and further detailed evidence-based recommendations are required for many of the topics covered here. PMID:25012948

  10. Analytical performance evaluation of a high-volume hematology laboratory utilizing sigma metrics as standard of excellence.

    Science.gov (United States)

    Shaikh, M S; Moiz, B

    2016-04-01

    Around two-thirds of important clinical decisions about the management of patients are based on laboratory test results. Clinical laboratories are required to adopt quality control (QC) measures to ensure provision of accurate and precise results. Six sigma is a statistical tool, which provides opportunity to assess performance at the highest level of excellence. The purpose of this study was to assess performance of our hematological parameters on sigma scale in order to identify gaps and hence areas of improvement in patient care. Twelve analytes included in the study were hemoglobin (Hb), hematocrit (Hct), red blood cell count (RBC), mean corpuscular volume (MCV), red cell distribution width (RDW), total leukocyte count (TLC) with percentages of neutrophils (Neutr%) and lymphocytes (Lymph %), platelet count (Plt), mean platelet volume (MPV), prothrombin time (PT), and fibrinogen (Fbg). Internal quality control data and external quality assurance survey results were utilized for the calculation of sigma metrics for each analyte. Acceptable sigma value of ≥3 was obtained for the majority of the analytes included in the analysis. MCV, Plt, and Fbg achieved value of performed poorly on both level 1 and 2 controls with sigma value of <3. Despite acceptable conventional QC tools, application of sigma metrics can identify analytical deficits and hence prospects for the improvement in clinical laboratories. © 2016 John Wiley & Sons Ltd.

  11. Virtual reality studies outside the laboratory

    DEFF Research Database (Denmark)

    Mottelson, Aske; Hornbæk, Kasper

    2017-01-01

    virtual reality (VR) studies outside laboratories remains unclear because these studies often use expensive equipment, depend critically on the physical context, and sometimes study delicate phenomena concerning body awareness and immersion. To investigate, we explore pointing, 3D tracing, and body......Many user studies are now conducted outside laboratories to increase the number and heterogeneity of participants. These studies are conducted in diverse settings, with the potential to give research greater external validity and statistical power at a lower cost. The feasibility of conducting......-illusions both in-lab and out-of-lab. The in-lab study was carried out as a traditional experiment with state-of-the-art VR equipment; 31 completed the study in our laboratory. The out-of-lab study was conducted by distributing commodity cardboard VR glasses to participants; 57 completed the study anywhere...

  12. GeoBrain Computational Cyber-laboratory for Earth Science Studies

    Science.gov (United States)

    Deng, M.; di, L.

    2009-12-01

    Computational approaches (e.g., computer-based data visualization, analysis and modeling) are critical for conducting increasingly data-intensive Earth science (ES) studies to understand functions and changes of the Earth system. However, currently Earth scientists, educators, and students have met two major barriers that prevent them from being effectively using computational approaches in their learning, research and application activities. The two barriers are: 1) difficulties in finding, obtaining, and using multi-source ES data; and 2) lack of analytic functions and computing resources (e.g., analysis software, computing models, and high performance computing systems) to analyze the data. Taking advantages of recent advances in cyberinfrastructure, Web service, and geospatial interoperability technologies, GeoBrain, a project funded by NASA, has developed a prototype computational cyber-laboratory to effectively remove the two barriers. The cyber-laboratory makes ES data and computational resources at large organizations in distributed locations available to and easily usable by the Earth science community through 1) enabling seamless discovery, access and retrieval of distributed data, 2) federating and enhancing data discovery with a catalogue federation service and a semantically-augmented catalogue service, 3) customizing data access and retrieval at user request with interoperable, personalized, and on-demand data access and services, 4) automating or semi-automating multi-source geospatial data integration, 5) developing a large number of analytic functions as value-added, interoperable, and dynamically chainable geospatial Web services and deploying them in high-performance computing facilities, 6) enabling the online geospatial process modeling and execution, and 7) building a user-friendly extensible web portal for users to access the cyber-laboratory resources. Users can interactively discover the needed data and perform on-demand data analysis and

  13. 78 FR 41926 - Proposed Information Collection Request; Comment Request; Performance Evaluation Studies on...

    Science.gov (United States)

    2013-07-12

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OECA-2013-0413; FRL--9832-8] Proposed Information Collection Request; Comment Request; Performance Evaluation Studies on Wastewater Laboratories (Renewal); EPA... request (ICR), ``Performance Evaluation Studies on Wastewater Laboratories'' (EPA ICR No. 0234.11, OMB...

  14. Performance assessment experience at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Lee, D.W.

    1994-01-01

    The development of a performance assessment (PA) for low-level radioactive waste disposal operations at Oak Ridge National Laboratory (ORNL) was initiated in 1989 and is continuing. A draft PA was prepared in September 1990 and submitted to the DOE Peer Review Panel for review and comment. Recommendations were received that formed the basis for a revised PA that was completed in December 1993. The review of the revised PA is continuing. This paper reviews the experience gained in the preparation of the PA including the technical difficulties associated with performance assessment in Oak Ridge and an overview of the methods used in the PA. Changes in waste operations that resulted from the findings in the PA include improved waste acceptance criteria, waste certification, and waste management practices. The discussion includes issues that relate to the application of current performance objectives to older disposal facilities, which are being addressed as part of the CERCLA process

  15. The influence of uncertainties of measurements in laboratory performance evaluation by intercomparison program in radionuclide analyses of environmental samples

    International Nuclear Information System (INIS)

    Tauhata, L.; Vianna, M.E.; Oliveira, A.E. de; Clain, A.F.; Ferreira, A.C.M.; Bernardes, E.M.

    2000-01-01

    The accuracy and precision of results of the radionuclide analyses in environmental samples are widely claimed internationally due to its consequences in the decision process coupled to evaluation of environmental pollution, impact, internal and external population exposure. These characteristics of measurement of the laboratories can be shown clearly using intercomparison data, due to the existence of a reference value and the need of three determinations for each analysis. In intercomparison studies accuracy in radionuclide assays in low-level environmental samples has usually been the main focus in performance evaluation and it can be estimated by taking into account the deviation between the experimental laboratory mean value and the reference value. The laboratory repeatability of measurements or their standard deviation is seldom included in performance evaluation. In order to show the influence of the uncertainties in performance evaluation of the laboratories, data of 22 intercomparison runs which distributed 790 spiked environmental samples to 20 Brazilian participant laboratories were compared, using the 'Normalised Standard Deviation' as statistical criteria for performance evaluation of U.S.EPA. It mainly takes into account the laboratory accuracy and the performance evaluation using the same data classified by normalised standard deviation modified by a weight reactor that includes the individual laboratory uncertainty. The results show a relative decrease in laboratory performance in each radionuclide assay: 1.8% for 65 Zn, 2.8% for 40 K, 3.4 for 60 Co, 3.7% for 134 Cs, 4.0% for 137 Cs, 4.4% for Th and U nat , 4.5% for 3 H, 6.3% for 133 Ba, 8.6% for 90 Sr, 10.6% for Gross Alpha, 10.9% for 106 Ru, 11.1% for 226 Ra, 11.5% for Gross Beta and 13.6% for 228 Ra. The changes in the parameters of the statistical distribution function were negligible and the distribution remained as Gaussian type for all radionuclides analysed. Data analyses in terms of

  16. Doubling immunochemistry laboratory testing efficiency with the cobas e 801 module while maintaining consistency in analytical performance.

    Science.gov (United States)

    Findeisen, P; Zahn, I; Fiedler, G M; Leichtle, A B; Wang, S; Soria, G; Johnson, P; Henzell, J; Hegel, J K; Bendavid, C; Collet, N; McGovern, M; Klopprogge, K

    2018-06-04

    The new immunochemistry cobas e 801 module (Roche Diagnostics) was developed to meet increasing demands on routine laboratories to further improve testing efficiency, while maintaining high quality and reliable data. During a non-interventional multicenter evaluation study, the overall performance, functionality and reliability of the new module was investigated under routine-like conditions. It was tested as a dedicated immunochemistry system at four sites and as a consolidator combined with clinical chemistry at three sites. We report on testing efficiency and analytical performance of the new module. Evaluation of sample workloads with site-specific routine request patterns demonstrated increased speed and almost doubled throughput (maximal 300 tests per h), thus revealing that one cobas e 801 module can replace two cobas e 602 modules while saving up to 44% floor space. Result stability was demonstrated by QC analysis per assay throughout the study. Precision testing over 21 days yielded excellent results within and between labs, and, method comparison performed versus the cobas e 602 module routine results showed high consistency of results for all assays under study. In a practicability assessment related to performance and handling, 99% of graded features met (44%) or even exceeded (55%) laboratory expectations, with enhanced reagent management and loading during operation being highlighted. By nearly doubling immunochemistry testing efficiency on the same footprint as a cobas e 602 module, the new module has a great potential to further consolidate and enhance laboratory testing while maintaining high quality analytical performance with Roche platforms. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Analytical performances of food microbiology laboratories - critical analysis of 7 years of proficiency testing results.

    Science.gov (United States)

    Abdel Massih, M; Planchon, V; Polet, M; Dierick, K; Mahillon, J

    2016-02-01

    Based on the results of 19 food microbiology proficiency testing (PT) schemes, this study aimed to assess the laboratory performances, to highlight the main sources of unsatisfactory analytical results and to suggest areas of improvement. The 2009-2015 results of REQUASUD and IPH PT, involving a total of 48 laboratories, were analysed. On average, the laboratories failed to detect or enumerate foodborne pathogens in 3·0% of the tests. Thanks to a close collaboration with the PT participants, the causes of outliers could be identified in 74% of the cases. The main causes of erroneous PT results were either pre-analytical (handling of the samples, timing of analysis), analytical (unsuitable methods, confusion of samples, errors in colony counting or confirmation) or postanalytical mistakes (calculation and encoding of results). PT schemes are a privileged observation post to highlight analytical problems, which would otherwise remain unnoticed. In this perspective, this comprehensive study of PT results provides insight into the sources of systematic errors encountered during the analyses. This study draws the attention of the laboratories to the main causes of analytical errors and suggests practical solutions to avoid them, in an educational purpose. The observations support the hypothesis that regular participation to PT, when followed by feed-back and appropriate corrective actions, can play a key role in quality improvement and provide more confidence in the laboratory testing results. © 2015 The Society for Applied Microbiology.

  18. Design study of the underground facilities, the Mizunami Underground Research Laboratory

    International Nuclear Information System (INIS)

    Ishizuka, Mineo; Noda, Masaru; Shiogama, Yukihiro; Adachi, Tetsuya

    1999-02-01

    Geoscientific research on the deep geological environment has been performed by Japan Nuclear Cycle Development Institute (JNC). This research is supported by the 'Long-Term Program for Research, Development and Utilization of Nuclear Energy'. The Mizunami Underground Research Laboratory (MIU) is planned to be constructed at the Shobasama-bora site belonging to JNC. A wide range of geoscientific research and development activities which have been previously performed in and around the Tono mine is planned to be expanded in the laboratory. The MIU consisted of surface and underground facilities excavated to a depth of about 1,000 meters. In this design study, the overall layout and basic design of the underground facility and the composition of the overall research program, includes the construction of the underground facility are studied. Based on the concept of the underground facility which have been developed in 1998, the research activities which will be performed in the MIU are selected and the overall research program is revised in this year. The basic construction method and the construction equipment are also estimated. (author)

  19. Design study of underground facility of the Mizunami Underground Research Laboratory

    International Nuclear Information System (INIS)

    Ishizuka, Mineo; Noda, Masaru; Shiogama, Yukihiro; Adachi, Tetsuya

    1999-02-01

    Geoscientific research on deep geological environment has been performed by Japan Nuclear Cycle Development Institute (JNC). This research is supported by the 'Long-Term Program for Research, Development and Utilization of Nuclear Energy'. The Mizunami Underground Research Laboratory (MIU) is planned to be constructed at Shobasama-bora site belonging to JNC. A wide range of geoscientific research and development activities which have been previously performed in and around the Tono mine is planned to be expanded in the laboratory. The MIU is consisted of surface and underground facilities down to the depth of about 1,000 meters. In this design study, the overall layout and basic design of the underground facility and the composition of the overall research program which includes the construction of the underground facility are studied. Based on the concept of the underground facility which have been developed last year, the research activities which will be performed in the MIU are selected and the overall research program is revised in this year. The basic construction method and the construction equipment are also estimated. (author)

  20. Evaluation of the performance of existing non-laboratory based cardiovascular risk assessment algorithms

    Science.gov (United States)

    2013-01-01

    Background The high burden and rising incidence of cardiovascular disease (CVD) in resource constrained countries necessitates implementation of robust and pragmatic primary and secondary prevention strategies. Many current CVD management guidelines recommend absolute cardiovascular (CV) risk assessment as a clinically sound guide to preventive and treatment strategies. Development of non-laboratory based cardiovascular risk assessment algorithms enable absolute risk assessment in resource constrained countries. The objective of this review is to evaluate the performance of existing non-laboratory based CV risk assessment algorithms using the benchmarks for clinically useful CV risk assessment algorithms outlined by Cooney and colleagues. Methods A literature search to identify non-laboratory based risk prediction algorithms was performed in MEDLINE, CINAHL, Ovid Premier Nursing Journals Plus, and PubMed databases. The identified algorithms were evaluated using the benchmarks for clinically useful cardiovascular risk assessment algorithms outlined by Cooney and colleagues. Results Five non-laboratory based CV risk assessment algorithms were identified. The Gaziano and Framingham algorithms met the criteria for appropriateness of statistical methods used to derive the algorithms and endpoints. The Swedish Consultation, Framingham and Gaziano algorithms demonstrated good discrimination in derivation datasets. Only the Gaziano algorithm was externally validated where it had optimal discrimination. The Gaziano and WHO algorithms had chart formats which made them simple and user friendly for clinical application. Conclusion Both the Gaziano and Framingham non-laboratory based algorithms met most of the criteria outlined by Cooney and colleagues. External validation of the algorithms in diverse samples is needed to ascertain their performance and applicability to different populations and to enhance clinicians’ confidence in them. PMID:24373202

  1. Results of tritium tests performed on Sandia Laboratories decontamination system

    International Nuclear Information System (INIS)

    Gildea, P.D.; Wall, W.R.; Gede, V.P.

    1978-05-01

    The Tritium Research Laboratory (TRL), a facility for performing experiments using gram amounts of tritium, became operational on October 1, 1977. As secondary containment, the TRL employs sealed glove boxes connected on demand to two central decontamination systems, the Gas Purification System and the Vacuum Effluent Recovery System. Performance tests on these systems show the tritium removal systems can achieve concentration reduction factors (ratio of inlet to exhaust concentrations) much in excess of 1000 per pass at inlet concentrations of 1 part per million or less for both tritium and tritiated methane

  2. Laboratory septic tank performance response to electrolytic stimulation.

    Science.gov (United States)

    Zaveri, Rahul M; Flora, Joseph R V

    2002-11-01

    This research investigated the effects of electrolytic stimulation on the performance of two laboratory-scale septic tanks. The tanks were fed a synthetic solution that included cellulose, peptone trypticase, beef extract, and urea. After a baseline period with no passed current, currents ranging from 100 to 500 mA were passed through the electrodes. The chemical oxygen demand (COD) removal efficiency from the tanks improved when a current was passed, with higher removal efficiencies observed at higher levels of passed current. Hydrolytic reactions resulted in ammonia and phosphate levels in the tanks that were higher than the influent. At currents > 300 mA, these hydrolytic reactions were suppressed, resulting in phosphate levels similar to the influent and ammonia levels lower than the influent because of the settling of ammonia-containing components of the feed solution. A slight increase in nitrate levels was observed when a current was passed, indicating minimal stimulation of nitrification activity. Abiotic studies confirmed that the COD can be removed via electrolysis and the removal was proportional to the passed current. Under the conditions of this study, the primary benefit of electrolytic stimulation of the septic tank is enhanced COD removal.

  3. Zero-gravity cloud physics laboratory: Experiment program definition and preliminary laboratory concept studies

    Science.gov (United States)

    Eaton, L. R.; Greco, E. V.

    1973-01-01

    The experiment program definition and preliminary laboratory concept studies on the zero G cloud physics laboratory are reported. This program involves the definition and development of an atmospheric cloud physics laboratory and the selection and delineations of a set of candidate experiments that must utilize the unique environment of zero gravity or near zero gravity.

  4. Laboratory design for high-performance electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    O' Keefe, Michael A.; Turner, John H.; Hetherington, Crispin J.D.; Cullis, A.G.; Carragher, Bridget; Jenkins, Ron; Milgrim, Julie; Milligan,Ronald A.; Potter, Clinton S.; Allard, Lawrence F.; Blom, Douglas A.; Degenhardt, Lynn; Sides, William H.

    2004-04-23

    Proliferation of electron microscopes with field emission guns, imaging filters and hardware spherical aberration correctors (giving higher spatial and energy resolution) has resulted in the need to construct special laboratories. As resolutions improve, transmission electron microscopes (TEMs) and scanning transmission electron microscopes (STEMs) become more sensitive to ambient conditions. State-of-the-art electron microscopes require state-of-the-art environments, and this means careful design and implementation of microscope sites, from the microscope room to the building that surrounds it. Laboratories have been constructed to house high-sensitive instruments with resolutions ranging down to sub-Angstrom levels; we present the various design philosophies used for some of these laboratories and our experiences with them. Four facilities are described: the National Center for Electron Microscopy OAM Laboratory at LBNL; the FEGTEM Facility at the University of Sheffield; the Center for Integrative Molecular Biosciences at TSRI; and the Advanced Microscopy Laboratory at ORNL.

  5. Evolution of a residue laboratory network and the management tools for monitoring its performance.

    Science.gov (United States)

    Lins, E S; Conceição, E S; Mauricio, A De Q

    2012-01-01

    Since 2005 the National Residue & Contaminants Control Plan (NRCCP) in Brazil has been considerably enhanced, increasing the number of samples, substances and species monitored, and also the analytical detection capability. The Brazilian laboratory network was forced to improve its quality standards in order to comply with the NRCP's own evolution. Many aspects such as the limits of quantification (LOQs), the quality management systems within the laboratories and appropriate method validation are in continuous improvement, generating new scenarios and demands. Thus, efficient management mechanisms for monitoring network performance and its adherence to the established goals and guidelines are required. Performance indicators associated to computerised information systems arise as a powerful tool to monitor the laboratories' activity, making use of different parameters to describe this activity on a day-to-day basis. One of these parameters is related to turnaround times, and this factor is highly affected by the way each laboratory organises its management system, as well as the regulatory requirements. In this paper a global view is presented of the turnaround times related to the type of analysis, laboratory, number of samples per year, type of matrix, country region and period of the year, all these data being collected from a computerised system called SISRES. This information gives a solid background to management measures aiming at the improvement of the service offered by the laboratory network.

  6. Hertelendi Laboratory of Environmental Studies

    International Nuclear Information System (INIS)

    Svingor, E.; Molnar, M.; Palcsu, L.; Futo, I.; Rinyu, L.; Mogyorosi, M.; Major, Z.; Bihari, A.; Vodila, G.; Janovics, R.; Papp, L.; Major, I.

    2010-01-01

    1. Introduction. The Hertelendi Laboratory for Environmental Studies (HEKAL) belongs to the Section of Environmental and Earth Sciences. It is a multidisciplinary laboratory dedicated to environmental research, to the development of nuclear analytical methods and to systems technology. During its existence of more than 15 years it has gained some reputation as a prime laboratory of analytical techniques, working with both radio- and stable isotopes. It has considerable expertise in isotope concentration measurements, radiocarbon dating, tritium measurements, in monitoring radioactivity around nuclear facilities and in modelling the movement of radionuclides in the environment. Many of its projects are within the scope of interest of the Paks Nuclear Power Plant. Our research activity is mainly concerned with the so-called environmental isotopes. This term denotes isotopes, both stable and radioactive, that are present in the natural environment either as a result of natural processes or of human activities. In environmental research isotopes are generally applied either as tracers or as age indicators. An ideal tracer is defined as a substance that behaves in the system studied exactly as the material to be traced as far as the examined parameters are concerned, but has at least one property that distinguishes it from the traced material. The mass number of an isotope is such an ideal indicator. In 2007 the laboratory assumed the name of Dr. Ede Hertelendi to honour the memory of the reputed environmental physicist who founded the group and headed it for many years. The current core of the laboratory staff is made up of his pupils and coworkers. This team was like a family to him. The group owes it to his fatherly figure that it did not fall apart after his death, but advanced with intense work and tenacity during the last decade. One of his first pupils, Mihaly Veres returned to the laboratory as a private entrepreneur and investor in 2005, and in the framework of

  7. Idaho National Laboratory Quarterly Event Performance Analysis FY 2013 4th Quarter

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Lisbeth A. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-11-01

    This report is published quarterly by the Idaho National Laboratory (INL) Performance Assurance Organization. The Department of Energy Occurrence Reporting and Processing System (ORPS) as prescribed in DOE Order 232.2 “Occurrence Reporting and Processing of Operations Information” requires a quarterly analysis of events, both reportable and not reportable for the previous twelve months. This report is the analysis of occurrence reports and deficiency reports (including not reportable events) identified at the Idaho National Laboratory (INL) during the period of October 2012 through September 2013.

  8. LASCO: a performance assessment and training laboratory for containment and surveillance techniques

    International Nuclear Information System (INIS)

    Cuypers, M.; Landat, D.

    1991-01-01

    The use of Containment and Surveillance (C/S) techniques for the implementation of nuclear safeguards has increased substantially in recent years. Sealing and identification systems are used on a large scale and video surveillance is replacing gradually film camera systems. Furthermore many C/S systems are operated in an unattended mode. In order to evaluate the performances and assurance which can be obtained from C/S systems, JRC has installed a laboratory, called LaSCo, for testing C/S components and systems, simulating, where possible, field conditions. This laboratory includes facilities for training inspectors, for instance for reviewing aid of video pictures, use of integrated multisensor systems, evaluation of ultrasonic sealing methods. Several years ago, JRC installed a performance laboratory for NDA, called PERLA, which is now extensively used. LaSCo is expected to play the same role as PERLA but in the field of Containment and Surveillance and by extension to non nuclear measurements (e.g. Weighing, volume determinations). The newly built facilities and the first experimental lay-out of LaSCo are described. It is expected that industry and inspectors will make extensive use of LaSCo

  9. LABORATORY EVALUATION OF COMPACTABILITY AND PERFORMANCE OF WARM MIX ASPHALT

    Directory of Open Access Journals (Sweden)

    Allex Eduardo Álvarez Lugo

    Full Text Available Warm mix asphalt (WMA is the term used to describe the set of technologies that allow fabrication of asphalt mixtures at lower temperatures than those specified for conventional hot mix asphalt (HMA. This temperature reduction leads to advantages, compared to construction of HMA, that include energy savings, reduced emissions, and safer working conditions. However, WMA is a relatively new technology and several aspects are still under evaluation. This paper assesses some of these aspects including laboratory compactability and its relation to mixture design, and performance of WMA (i.e., permanent deformation and cracking resistance fabricated with three WMA additives, namely Advera®, Sasobit®, and Evotherm®. Corresponding results showed better or equivalent laboratory compactability for the WMA, as compared to that of the HMA used as reference (or control-HMA, leading to smaller optimum asphalt contents selected based on a specific target density (i.e., 96%. In terms of performance, inclusion of the WMA additives led to decrease the mixture resistance to permanent deformation, although the mixture resistance to cracking can remain similar or even improve as compared to that of the control-HMA.

  10. The impact of laboratory characteristics on molecular detection of respiratory syncytial virus in a European multicentre quality control study

    NARCIS (Netherlands)

    Meerhoff, T. J.; MacKay, W. G.; Meijer, A.; Paget, W. J.; Niesters, H. G. M.; Kimpen, J. L. L.; Schellevis, F.

    2008-01-01

    The performance of nucleic acid amplification techniques for detecting respiratory syncytial virus (RSV) was evaluated in 25 laboratories across Europe by an external quality assessment study. In addition, factors related to the diagnostic performance of laboratories were explored. The results of

  11. Chemistry Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose: To conduct fundamental studies of highway materials aimed at understanding both failure mechanisms and superior performance. New standard test methods are...

  12. Effect of skill laboratory training on academic performance of medical students.

    Science.gov (United States)

    Khan, Muhammad Alamgir; Shabbir, Faizania; Qamar, Khadija; Rajput, Tausif Ahmed

    2017-05-01

    To observe the effect of skill lab training on academic performance of final year medical students in terms of marks obtained in long case, short case, objective structured clinical examination and viva. The cross-sectional comparative study was conducted at Army Medical College, Rawalpindi from February to April 2015. Two batches of final year MBBS were recruited for the study. Batch 1 received conventional training, and Batch 2 received skill lab training. The performance of students was assessed by comparing the marks obtained in long case, short case, objective structured clinical examination and viva. Data was analysed using SPSS 23. Of the 335 subjects, 168(50.1%) were male and 167(49.9%) were female students with a mean age of 21.79±1.02 years. Batch 1 had 151(45%) students and Batch 2 had 184(55%). Batch 2 got significantly higher marks in long case, short case and objective structured clinical examination (p0.05). Acquisition of clinical skills significantly improved when medial students were trained in skill laboratories.

  13. Performance specifications for the extra-analytical phases of laboratory testing: Why and how.

    Science.gov (United States)

    Plebani, Mario

    2017-07-01

    An important priority in the current healthcare scenario should be to address errors in laboratory testing, which account for a significant proportion of diagnostic errors. Efforts made in laboratory medicine to enhance the diagnostic process have been directed toward improving technology, greater volumes and more accurate laboratory tests being achieved, but data collected in the last few years highlight the need to re-evaluate the total testing process (TTP) as the unique framework for improving quality and patient safety. Valuable quality indicators (QIs) and extra-analytical performance specifications are required for guidance in improving all TTP steps. Yet in literature no data are available on extra-analytical performance specifications based on outcomes, and nor is it possible to set any specification using calculations involving biological variability. The collection of data representing the state-of-the-art based on quality indicators is, therefore, underway. The adoption of a harmonized set of QIs, a common data collection and standardised reporting method is mandatory as it will not only allow the accreditation of clinical laboratories according to the International Standard, but also assure guidance for promoting improvement processes and guaranteeing quality care to patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Laboratory studies of dissolved radiolabelled microcystin-LR in lake water

    DEFF Research Database (Denmark)

    Hyenstrand, Per; Rohrlack, Thomas; Beattie, Kenneth A

    2003-01-01

    The fate of dissolved microcystin-LR was studied in laboratory experiments using surface water taken from a eutrophic lake. Based on initial range finding, a concentration of 50 microg l(-1) dissolved 14C-microcystin-LR was selected for subsequent time-course experiments. The first was performed ...... fractions. The study demonstrated that biodegradation of dissolved microcystin-LR occurred in water collected at a lake surface with carbon dioxide as a major end-product....

  15. Analytical quality, performance indices and laboratory service

    DEFF Research Database (Denmark)

    Hilden, Jørgen; Magid, Erik

    1999-01-01

    analytical error, bias, cost effectiveness, decision-making, laboratory techniques and procedures, mass screening, models, statistical, quality control......analytical error, bias, cost effectiveness, decision-making, laboratory techniques and procedures, mass screening, models, statistical, quality control...

  16. Noise study in laboratories with exhaust fans

    International Nuclear Information System (INIS)

    Shaikh, G.H.; Hashmi, R.; Shareef, A.

    2005-01-01

    Noise study has been carried out in 25 laboratories fitted with exhaust fans. We have studied A- Weighted equivalent sound pressure levels (dB(A) LAeJ and equivalent octave band sound pressure levels (dB L/sub eq/ in each of the laboratories surveyed. The data collected has been analyzed for Preferred Speech Interference Levels (PSIL). The results show that the interior noise levels in these laboratories vary from 59.6 to 72.2 dB(A) L/sub Aeq/, which are very high and much beyond the interior noise limits recommended for laboratories. Some ways and means to limit emission of high-level noise from exhaust fans are also discussed. (author)

  17. Investigation on Superior Performance by Fractional Controller for Cart-Servo Laboratory Set-Up

    Directory of Open Access Journals (Sweden)

    Ameya Anil Kesarkar

    2014-01-01

    Full Text Available In this paper, an investigation is made on the superiority of fractional PID controller (PI^alpha D^beta over conventional PID for the cart-servo laboratory set-up. The designed controllers are optimum in the sense of Integral Absolute Error (IAE and Integral Square Error (ISE. The paper contributes in three aspects: 1 Acquiring nonlinear mathematical model for the cart-servo laboratory set-up, 2 Designing fractional and integer order PID for minimizing IAE, ISE, 3 Analyzing the performance of designed controllers for simulated plant model as well as real plant. The results show a significantly superior performance by PI^alpha D^beta as compared to the conventional PID controller.

  18. Importance/performance analysis: a tool for service quality control by clinical laboratories.

    Science.gov (United States)

    Scammon, D L; Weiss, R

    1991-01-01

    A study of customer satisfaction with clinical laboratory service is used as the basis for identifying potential improvements in service and more effectively targeting marketing activities to enhance customer satisfaction. Data on customer satisfaction are used to determine the aspects of service most critical to customers, how well the organization is doing in delivery of service, and how consistent service delivery is. Importance-performance analysis is used to highlight areas for future resource reallocation and strategic emphasis. Suggestions include the establishment of performance guidelines for customer contact personnel, the enhancement of timely delivery of reports via electronic transmission (computer and fax), and the development of standardized graphics for request and report forms to facilitate identification of appropriate request forms and guide clients to key items of information on reports.

  19. Site Study Plan for laboratory soil mechanics, Deaf Smith County site, Texas: Revision 1

    International Nuclear Information System (INIS)

    1987-12-01

    This Site Study Plan for laboratory soil mechanics describes the laboratory testing to be conducted on soil samples collected as part of the characterization of the Deaf Smith County site, Texas. This study provides for measurements of index, mechanical, thermal, hydrologic, chemical, and mineral properties of soils from boring throughout the site. Samples will be taken from Playa Borings/Trenching, Transportation/Utilities Foundation Borings, Repository Surface Facilities Design Foundation Borings, and Exploratory Shaft Facilities Design Foundation Borings. Data from the laboratory tests will be used for soil strata characterization, design of foundations for surface structures, design of transportation facilities and utility structures, design of impoundments, design of shaft lining, design of the shaft freeze wall, shaft permitting, performance assessment calculations, and other program requirements. A tentative testing schedule and milestone log are given. A quality assurance program will be utilized to assure that activities affecting quality are performed correctly and that appropriate documentation is maintained. 18 refs., 6 figs., 3 tabs

  20. Procedures of Exercise Physiology Laboratories

    Science.gov (United States)

    Bishop, Phillip A.; Fortney, Suzanne; Greenisen, Michael; Siconolfi, Steven F.; Bamman, Marcas M.; Moore, Alan D., Jr.; Squires, William

    1998-01-01

    This manual describes the laboratory methods used to collect flight crew physiological performance data at the Johnson Space Center. The Exercise Countermeasures Project Laboratory is a standard physiology laboratory; only the application to the study of human physiological adaptations to spaceflight is unique. In the absence of any other recently published laboratory manual, this manual should be a useful document staffs and students of other laboratories.

  1. Lessons from the use of genetically modified Drosophila melanogaster in ecological studies: Hsf mutant lines show highly trait-specific performance in field and laboratory thermal assays

    DEFF Research Database (Denmark)

    Sørensen, Jesper Givskov; Loeschcke, Volker; Kristensen, Torsten Nygård

    2009-01-01

    . 2.  We have tested the importance of inducible heat shock proteins (Hsps) under different thermal conditions using two heat shock factor (Hsf) mutant lines (either able (Hsf+) or unable (Hsf0) to mount a heat stress response) and an outbred laboratory adapted wild-type line of Drosophila......1.  Laboratory studies on genetically modified strains may reveal important information on mechanisms involved in coping with thermal stress. However, to address the evolutionary significance of specific genes or physiological mechanisms, ecologically relevant field tests should also be performed...

  2. Country-wide quality control of equipment in Norwegian laboratories performing in vivo nuclear medicine examinations

    International Nuclear Information System (INIS)

    Skretting, A.; Rootwelt, K.; Berthelsen, T.

    1984-01-01

    The report presents the methods used and the results obtained in quality control tests performd in all Norwegian hospital laboratories performing in vivo nuclear medicine examinations. The tests included activity meters and scintillation cameras. The activity meters were tested by means of calibrated, long-lived radioactive sources. The quality of these instruments were judged to be satisfactory for moderate and high activities, non of them showing a deviation of more than 10% from the calibration value. Deviations were larger at low activities and were for some laboratories unacceptable. The scintillation cameras test included studies of flood field (homogeneity), geometrical resolution and energy resolution, as well as measurements of count rate characteristics and sensitivity. 40% of the cameras were judged to have flood field responses with satisfactory homogeneity, whereas 32% of the cameras had a satisfactory resolution ability. A liver/abdomen phantom test was carried out by the staff of the actual laboratory. This test proved that only 20% of the laboratories had a satisfactory total performance, managing to detect and describe satisfactorily 4 out of 5 simulated defects in the liver phantom. Lack of information density and insufficient number of projections was the main reason for unsatisfactory results with good cameras. It is recommended that quality control equipment as used in the described tests should be made available to Norwegian hospitals for self assessment. Regular quality assurance tests as recommended by the Norwegian Association for Radiation Physics and Norwegian Society of Nuclear Medicine should be implemented in all hospitals. Moreover, a practical training course in quality assurance should be arranged. (RF)

  3. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Hudon, K.; Christensen, D.

    2014-06-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of U.S. climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt™ whole-house building simulations.

  4. Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Hudon, K.; Christensen, D.

    2014-06-01

    This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

  5. Application of laboratory data from small-scale simulators to human performance issues in the nuclear industry

    International Nuclear Information System (INIS)

    Spettell, C.M.

    1986-01-01

    Laboratory analogs of nuclear power plant tasks were simulated on personal computers in two experimental studies. Human performance data were collected during each experimental study. The goal of the first experiment was to validate a quantitative model of dependence among human errors during testing, calibration, and maintenance activities. This model, the Multiple Sequential Failure (MSF) model (NUREG/CR-2211) has been used to quantify dependent human error failure probabilities for human reliability analyses in Probabilistic Risk Assessments (PRAs). The goal of the second experiment was to examine the relationship among psychological and behavioral characteristics of individuals and their performance at controlling a simulated nuclear power plant. These studies demonstrated the usefulness of the experimental psychology approach for validating models of human performance at nuclear power plant tasks

  6. Criticality accident studies and research performed in the Valduc criticality laboratory, France

    International Nuclear Information System (INIS)

    Barbry, F.; Fouillaud, P.

    2001-01-01

    In 1967, the IPSN (Institut de Protection et de Surete Nucleaire - Nuclear Protection and Safety Institute) started studies and research in France on criticality accidents, with the objective of improving knowledge and modelling of accidents in order to limit consequences to the public, the environment and installations. The criticality accident is accompanied by an intense emission of neutronic and gamma radiation and releases of radioactive products in the form of gas and aerosols, generating irradiation and contamination risks. The main objectives of the studies carried out, particularly using the CRAC installation and the SILENE reactor at Valduc (France), were to model the physics of criticality accidents, to estimate the risks of irradiation and radioactive releases, to elaborate an accident detection system and to provide information for intervention plans. This document summarizes the state of knowledge in the various fields mentioned above. The results of experiments carried out in the Valduc criticality laboratory are used internationally as reference data for the qualification of calculation codes and the assessment of the consequences of a criticality accident. The SILENE installation, that reproduces the various conditions encountered during a criticality accident, is also a unique international research tool for studies and training on those matters. (author)

  7. Evaluating Laboratory Performance on Point-of-Care Glucose Testing with Six Sigma Metric for 151 Institutions in China.

    Science.gov (United States)

    Fei, Yang; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo

    2015-10-01

    The aim of this study was to use Six Sigma(SM) (Motorola Trademark Holdings, Libertyville, IL) techniques to analyze the quality of point-of-care (POC) glucose testing measurements quantitatively and to provide suggestions for improvement. In total, 151 laboratories in China were included in this investigation in 2014. Bias and coefficient of variation were collected from an external quality assessment and an internal quality control program, respectively, for POC glucose testing organized by the National Center for Clinical Laboratories. The σ values and the Quality Goal Index were used to evaluate the performance of POC glucose meters. There were 27, 30, 57, and 37 participants in the groups using Optium Xceed™ (Abbott Diabetes Care, Alameda, CA), Accu-Chek(®) Performa (Roche, Basel, Switzerland), One Touch Ultra(®) (Abbott), and "other" meters, respectively. The median of the absolute value of percentage difference varied among different lots and different groups. Among all the groups, the Abbott One Touch Ultra group had the smallest median of absolute value of percentage difference except for lot 201411, whereas the "other" group had the largest median in all five lots. More than 85% of participate laboratories satisfied the total allowable error (TEa) requirement in International Organization for Standardization standard 15197:2013, and 85.43% (129/151) of laboratories obtained intralaboratory coefficient of variations less than 1/3TEa. However, Six Sigma techniques suggested that 41.72% (63/151) to 65.56% (99/151) of the laboratories needed to improve their POC glucose testing performance, in either precision, trueness, or both. Laboratories should pay more attention on the practice of POC glucose testing and take actions to improve their performance. Only in this way can POC glucose testing really function well in clinical practice.

  8. Improvement in the performance of external quality assessment in Korean HIV clinical laboratories using unrecalcified human plasma.

    Science.gov (United States)

    Wang, Jin-Sook; Kee, Mee-Kyung; Choi, Byeong-Sun; Kim, Chan-Wha; Kim, Hyon-Suk; Kim, Sung Soon

    2012-01-01

    The external quality assessment schemes (EQAS) organizer provides a suitable program to monitor and improve the quality of human immunodeficiency virus (HIV) testing laboratories with EQAS panels prepared under various conditions. The aim of the current study was to investigate the effects of human plasma samples on the EQAS results of HIV obtained from hospital-based clinical laboratories. From 2007 to 2009, HIV EQAS panels consisted of four to six samples that consisted of undiluted positive and negative samples and were provided to laboratories twice per year. Up until the first half EQAS in 2008, EQAS panel materials were obtained by converting acid citrate dextrose treated plasma to serum via chemical treatment with CaCl2. Beginning with the second EQAS in 2008, all materials were prepared without the defibrination process. Approximately 300 HIV clinical laboratories participated in this program. The overall performance of clinical laboratories was shown to be improved when using unrecalcified plasma panels compared with recalcified panels. Significant differences were observed in EIA analyses of plasma for both positive (plaboratories.

  9. Performance of the RAD-57 pulse CO-oximeter compared with standard laboratory carboxyhemoglobin measurement.

    Science.gov (United States)

    Touger, Michael; Birnbaum, Adrienne; Wang, Jessica; Chou, Katherine; Pearson, Darion; Bijur, Polly

    2010-10-01

    We assess agreement between carboxyhemoglobin levels measured by the Rad-57 signal extraction pulse CO-oximeter (RAD), a Food and Drug Administration-approved device for noninvasive bedside measurement, and standard laboratory arterial or venous measurement in a sample of emergency department (ED) patients with suspected carbon monoxide poisoning. The study was a cross-sectional cohort design using a convenience sample of adult and pediatric ED patients in a Level I trauma, burn, and hyperbaric oxygen referral center. Measurement of RAD carboxyhemoglobin was performed simultaneously with blood sampling for laboratory determination of carboxyhemoglobin level. The difference between the measures for each patient was calculated as laboratory carboxyhemoglobin minus carboxyhemoglobin from the carbon monoxide oximeter. The limits of agreement from a Bland-Altman analysis are calculated as the mean of the differences between methods ±1.96 SDs above and below the mean. Median laboratory percentage carboxyhemoglobin level was 2.3% (interquartile range 1 to 8.5; range 0% to 38%). The mean difference between laboratory carboxyhemoglobin values and RAD values was 1.4% carboxyhemoglobin (95% confidence interval [CI] 0.2% to 2.6%). The limits of agreement of differences of measurement made with the 2 devices were -11.6% and 14.4% carboxyhemoglobin. This range exceeded the value of ±5% carboxyhemoglobin defined a priori as clinically acceptable. RAD correctly identified 11 of 23 patients with laboratory values greater than 15% carboxyhemoglobin (sensitivity 48%; 95% CI 27% to 69%). There was one case of a laboratory carboxyhemoglobin level less than 15%, in which the RAD device gave a result greater than 15% (specificity of RAD 96/97=99%; 95% CI 94% to 100%). In the range of carboxyhemoglobin values measured in this sample, the level of agreement observed suggests RAD measurement may not be used interchangeably with standard laboratory measurement. Copyright © 2010 American

  10. Strategies to define performance specifications in laboratory medicine: 3 years on from the Milan Strategic Conference.

    Science.gov (United States)

    Panteghini, Mauro; Ceriotti, Ferruccio; Jones, Graham; Oosterhuis, Wytze; Plebani, Mario; Sandberg, Sverre

    2017-10-26

    Measurements in clinical laboratories produce results needed in the diagnosis and monitoring of patients. These results are always characterized by some uncertainty. What quality is needed and what measurement errors can be tolerated without jeopardizing patient safety should therefore be defined and specified for each analyte having clinical use. When these specifications are defined, the total examination process will be "fit for purpose" and the laboratory professionals should then set up rules to control the measuring systems to ensure they perform within specifications. The laboratory community has used different models to set performance specifications (PS). Recently, it was felt that there was a need to revisit different models and, at the same time, to emphasize the presuppositions for using the different models. Therefore, in 2014 the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) organized a Strategic Conference in Milan. It was felt that there was a need for more detailed discussions on, for instance, PS for EQAS, which measurands should use which models to set PS and how to set PS for the extra-analytical phases. There was also a need to critically evaluate the quality of data on biological variation studies and further discussing the use of the total error (TE) concept. Consequently, EFLM established five Task Finish Groups (TFGs) to address each of these topics. The TFGs are finishing their activity on 2017 and the content of this paper includes deliverables from these groups.

  11. Laboratory Experiments and Instrument Intercomparison Studies of Carbonaceous Aerosol Particles

    Energy Technology Data Exchange (ETDEWEB)

    Davidovits, Paul [Boston College, Chestnut Hill, MA (United States)

    2015-10-20

    Aerosols containing black carbon (and some specific types of organic particulate matter) directly absorb incoming light, heating the atmosphere. In addition, all aerosol particles backscatter solar light, leading to a net-cooling effect. Indirect effects involve hydrophilic aerosols, which serve as cloud condensation nuclei (CCN) that affect cloud cover and cloud stability, impacting both atmospheric radiation balance and precipitation patterns. At night, all clouds produce local warming, but overall clouds exert a net-cooling effect on the Earth. The effect of aerosol radiative forcing on climate may be as large as that of the greenhouse gases, but predominantly opposite in sign and much more uncertain. The uncertainties in the representation of aerosol interactions in climate models makes it problematic to use model projections to guide energy policy. The objective of our program is to reduce the uncertainties in the aerosol radiative forcing in the two areas highlighted in the ASR Science and Program Plan. That is, (1) addressing the direct effect by correlating particle chemistry and morphology with particle optical properties (i.e. absorption, scattering, extinction), and (2) addressing the indirect effect by correlating particle hygroscopicity and CCN activity with particle size, chemistry, and morphology. In this connection we are systematically studying particle formation, oxidation, and the effects of particle coating. The work is specifically focused on carbonaceous particles where the uncertainties in the climate relevant properties are the highest. The ongoing work consists of laboratory experiments and related instrument inter-comparison studies both coordinated with field and modeling studies, with the aim of providing reliable data to represent aerosol processes in climate models. The work is performed in the aerosol laboratory at Boston College. At the center of our laboratory setup are two main sources for the production of aerosol particles: (a

  12. LABORATORY EVALUATION ON PERFORMANCE OF GLASS FIBER REINFORCED PLASTIC MORTAR PIPE CULVERTS

    OpenAIRE

    Huawang Shi; Lianyu Wei

    2018-01-01

    This paper investigated the performance and behaviour of glass fiber reinforced plastic mortar (FRPM) pipes under different loading conditions. FRPM pipes with inner diameter of 1500 mm were prefabricated in factory. Mechanics performance testing (ring and axial compressive strength and elastic modulus), stiffness and fatigue test were carried out in laboratory. Ring stiffness test provided pipe stiffness (PS) which is a function of geometry and material type of pipe through parallel plate lo...

  13. Site study plan for routine laboratory rock mechanics, Deaf Smith County Site, Texas: Revision 1

    International Nuclear Information System (INIS)

    1987-12-01

    This Site Study Plan for Routine Laboratory Rock Mechanics describes routine laboratory testing to be conducted on rock samples collected as part of the characterization of the Deaf Smith County site, Texas. This study plan describes the early laboratory testing. Additional testing may be required and the type and scope of testing will be dependent upon the results of the early testing. This study provides for measurements of index, hydrological, mechanical, and chemical properties with tests which are standardized and used widely in geotechnical investigations. Another Site Study Plan for Nonroutine Laboratory Rock Mechanics describes laboratory testing of samples from the site to determine mechanical, thermomechanical, and thermal properties by less widely used methods, many of which have been developed specifically for characterization of the site. Data from laboratory tests will be used for characterization of rock strata, design of shafts and underground facilities, and modeling of repository behavior in support of resolution of both preclosure and postclosure issues. A tentative testing schedule and milestone log are given. A quality assurance program will be utilized to assure that activities affecting quality are performed correctly and that appropriate documentation is maintained. 18 refs., 8 figs., 3 tabs

  14. Multi-laboratory evaluations of the performance of Catellicoccus marimammalium PCR assays developed to target gull fecal sources

    Science.gov (United States)

    Sinigalliano, Christopher D.; Ervin, Jared S.; Van De Werfhorst, Laurie C.; Badgley, Brian D.; Ballestée, Elisenda; Bartkowiaka, Jakob; Boehm, Alexandria B.; Byappanahalli, Muruleedhara N.; Goodwin, Kelly D.; Gourmelon, Michèle; Griffith, John; Holden, Patricia A.; Jay, Jenny; Layton, Blythe; Lee, Cheonghoon; Lee, Jiyoung; Meijer, Wim G.; Noble, Rachel; Raith, Meredith; Ryu, Hodon; Sadowsky, Michael J.; Schriewer, Alexander; Wang, Dan; Wanless, David; Whitman, Richard; Wuertz, Stefan; Santo Domingo, Jorge W.

    2013-01-01

    Here we report results from a multi-laboratory (n = 11) evaluation of four different PCR methods targeting the 16S rRNA gene of Catellicoccus marimammalium originally developed to detect gull fecal contamination in coastal environments. The methods included a conventional end-point PCR method, a SYBR® Green qPCR method, and two TaqMan® qPCR methods. Different techniques for data normalization and analysis were tested. Data analysis methods had a pronounced impact on assay sensitivity and specificity calculations. Across-laboratory standardization of metrics including the lower limit of quantification (LLOQ), target detected but not quantifiable (DNQ), and target not detected (ND) significantly improved results compared to results submitted by individual laboratories prior to definition standardization. The unit of measure used for data normalization also had a pronounced effect on measured assay performance. Data normalization to DNA mass improved quantitative method performance as compared to enterococcus normalization. The MST methods tested here were originally designed for gulls but were found in this study to also detect feces from other birds, particularly feces composited from pigeons. Sequencing efforts showed that some pigeon feces from California contained sequences similar to C. marimammalium found in gull feces. These data suggest that the prevalence, geographic scope, and ecology of C. marimammalium in host birds other than gulls require further investigation. This study represents an important first step in the multi-laboratory assessment of these methods and highlights the need to broaden and standardize additional evaluations, including environmentally relevant target concentrations in ambient waters from diverse geographic regions.

  15. National intercomparison programme for radionuclide analysis in environmental samples: Aramar radioecological laboratory performance

    Energy Technology Data Exchange (ETDEWEB)

    Arine, Bruno Burini Robles, E-mail: bruno.arine@ctmsp.mar.mil.b [Centro Tecnologico da Marinha em Sao Paulo (CTMSP/ARAMAR), Ipero, SP (Brazil). Lab. Radioecologico; Moraes, Marco Antonio P.V., E-mail: marco.proenca@ctmsp.mar.mil.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The radioecological laboratory is concerned with the measurements of background radiation (mainly uranium and thorium natural series) and present effluents in the Aramar Experimental Centre, as well as in its surroundings. The laboratory is directly subordinated to the Navy Technological Centre in Sao Paulo (CTMSP - Sao Paulo - Brazil), a military research organization whose goal is to develop nuclear and energy systems for the Brazilian naval ship propulsion. The measurements were performed in addition to the Environmental Monitoring Programme carried out in the same region. For this endeavour, the laboratory has attended to the National Intercomparison Programme conducted by the Institute for Radioprotection and Dosimetry (IRD) by analyzing several kinds of solid and liquid samples containing specific radionuclides through gamma spectrometry, liquid scintillation, alpha-beta total counting and fluorimetry techniques, since December 1995. In the last 15 years, our results were compared to another 19 laboratories and rated as 'very good' and 'acceptable' in at least 90% of the results. (author)

  16. Laboratory- and field-based testing as predictors of skating performance in competitive-level female ice hockey

    Directory of Open Access Journals (Sweden)

    Henriksson T

    2016-08-01

    Full Text Available Tommy Henriksson,1,2 Jason D Vescovi,3 Anncristine Fjellman-Wiklund,4 Kajsa Gilenstam1 1Sport Medicine Unit, Department of Community Medicine and Rehabilitation, 2The National Graduate School of Gender Studies, Umeå University, Umeå, Sweden; 3Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, ON, Canada; 4Physiotherapy Unit, Department of Community Medicine and Rehabilitation, Umeå University, Umeå, Sweden Objectives: The purpose of this study was to examine whether field-based and/or laboratory-based assessments are valid tools for predicting key performance characteristics of skating in competitive-level female hockey players.Design: Cross-sectional study.Methods: Twenty-three female ice hockey players aged 15–25 years (body mass: 66.1±6.3 kg; height: 169.5±5.5 cm, with 10.6±3.2 years playing experience volunteered to participate in the study. The field-based assessments included 20 m sprint, squat jump, countermovement jump, 30-second repeated jump test, standing long jump, single-leg standing long jump, 20 m shuttle run test, isometric leg pull, one-repetition maximum bench press, and one-repetition maximum squats. The laboratory-based assessments included body composition (dual energy X-ray absorptiometry, maximal aerobic power, and isokinetic strength (Biodex. The on-ice tests included agility cornering s-turn, cone agility skate, transition agility skate, and modified repeat skate sprint. Data were analyzed using stepwise multivariate linear regression analysis. Linear regression analysis was used to establish the relationship between key performance characteristics of skating and the predictor variables.Results: Regression models (adj R2 for the on-ice variables ranged from 0.244 to 0.663 for the field-based assessments and from 0.136 to 0.420 for the laboratory-based assessments. Single-leg tests were the strongest predictors for key performance characteristics of skating. Single leg standing

  17. The recording of student performance in the microbiology laboratory as a training, tutorial, and motivational tool.

    Science.gov (United States)

    Lipson, Steven M; Gair, Marina

    2011-01-01

    The laboratory component of a microbiology course consists of exercises which mandate a level of proficiency and manual dexterity equal to and often beyond that recognized among other biology courses. Bacterial growth, maintenance, identification (e.g., Gram stain, biochemical tests, genomics), as well as the continuous need to maintain laboratory safety and sterile technique, are only a few skills/responsibilities critical to the discipline of microbiology. Performance of the Gram stain remains one of the most basic and pivotal skills that must be mastered in the microbiology laboratory. However, a number of students continually have difficulty executing the Gram stain and preparative procedures associated with the test. In order to address this issue, we incorporated real-time digital recording as a supplemental teaching aid in the microbiology laboratory. Our use of the digital movie camera in the teaching setting served to enhance interest, motivate students, and in general, improve student performance.

  18. Use of proficiency samples to assess diagnostic laboratories in France performing a Trichinella digestion assay.

    Science.gov (United States)

    Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal

    2007-07-01

    Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.

  19. Lawrence Livermore National Laboratory low-level waste systems performance assessment

    International Nuclear Information System (INIS)

    1990-11-01

    This Low-Level Radioactive Waste (LLW) Systems Performance Assessment (PA) presents a systematic analysis of the potential risks posed by the Lawrence Livermore National Laboratory (LLNL) waste management system. Potential risks to the public and environment are compared to established performance objectives as required by DOE Order 5820.2A. The report determines the associated maximum individual committed effective dose equivalent (CEDE) to a member of the public from LLW and mixed waste. A maximum annual CEDE of 0.01 mrem could result from routine radioactive liquid effluents. A maximum annual CEDE of 0.003 mrem could result from routine radioactive gaseous effluents. No other pathways for radiation exposure of the public indicated detectable levels of exposure. The dose rate, monitoring, and waste acceptance performance objectives were found to be adequately addressed by the LLNL Program. 88 refs., 3 figs., 17 tabs

  20. Laboratory performance testing of an extruded bitumen containing a surrogate, sodium nitrate-based, low-level aqueous waste

    International Nuclear Information System (INIS)

    Mattus, A.J.; Kaczmarsky, M.M.

    1986-01-01

    Laboratory results of a comprehensive, regulatory performance test program, utilizing an extruded bitumen and a surrogate, sodium nitrate-based waste, have been compiled at the Oak Ridge National Laboratory (ORNL). Using a 53 millimeter, Werner and Pfleiderer extruder, operated by personnel of WasteChem Corporation of Paramus, New Jersey, laboratory-scale, molded samples of type three, air blown bitumen were prepared for laboratory performance testing. A surrogate, low-level, mixed liquid waste, formulated to represent an actual on-site waste at ORNL, containing about 30 wt % sodium nitrate, in addition to eight heavy metals, cold cesium and strontium was utilized. Samples tested contained three levels of waste loading: that is, forty, fifty and sixty wt % salt. Performance test results include the ninety day ANS 16.1 leach test, with leach indices reported for all cations and anions, in addition to the EP Toxicity test, at all levels of waste loading. Additionally, test results presented also include the unconfined compressive strength and surface morphology utilizing scanning electron microscopy. Data presented include correlations between waste form loading and test results, in addition to their relationship to regulatory performance requirements

  1. Technical performance of cementitious grouting materials for ONKALO. Laboratory tests 2006

    International Nuclear Information System (INIS)

    Raivio, P.; Hansen, J.

    2007-09-01

    During 2006 the development of high and low-pH cementitious grouts for fractures > 100 μm designed for the ONKALO rock was continued within the LPHTEK/IMAproject. The main focus in laboratory was to study high pH micro cement grouts. The low pH (≥ 11.0) of the cementitious grout material is required in deep repository as natural pH plume deriving from pure cement paste is very high and moves via ground water circulation in bedrock. This may be deleterious to the protective covers of nuclear waste. The objective to study high pH grouts in laboratory was to optimise their composition and to get preliminary test results. Low pH grouts based on Portland cement + micro silica were also studied further in laboratory to understand their behaviour more thoroughly in different conditions and due to quality changes in materials and to compare the laboratory results with the field results. Alternative fine-grained glass material was briefly studied to replace silica in low pH grout. Low and high pH rock bolt mortars were also developed and tested to get the preliminary test results. The results of the 2006 laboratory work are presented in this report. The high pH micro cement mix U1 with no silica, mix 5/5 with moderate silica and low pH mix P308B rich in silica show generally good properties at fresh and hardening stage at +12 deg C. Lower temperature gives weaker strength build-up with all the mixes and weakens especially the Marsh fluidity and penetration ability of the mixes 5/5 and P308B as bulk density rises a little at lower temperature. Cement quality variation and insufficient mixing may also weaken the properties of all mixes. Deformation of the hardened mixes was observed in laboratory tests. This may weaken their durability if cracks are formed in the grouts at later ages and need to be studied more thoroughly. (orig.)

  2. A study of 6S workplace improvement in Ergonomic Laboratory

    Science.gov (United States)

    Sari, AD; Suryoputro, MR; Rahmillah, FI

    2017-12-01

    This article discusses 6S implementation in Ergonomic Laboratory, Department of Industrial Engineering, Islamic University of Indonesia. This research is improvement project of 5S implementation in Ergonomic laboratory. Referring to the 5S implementation of the previous year, there have been improvements from environmental conditions or a more organized workplace however there is still a lack of safety aspects. There are several safeties problems such as equipment arrangement, potential hazards of room dividers that cause injury several times, placement of fire extinguisher, no evacuation path and assembly point in case of fire, as well as expired hydrant condition and lack of awareness of stakeholders related to safety. Therefore, this study aims to apply the 6S kaizen method to the Ergonomic laboratory to facilitate the work process, reduce waste, improve work safety and improve staff performance. Based on the score 6S assessment increased audit results by 32 points, before implementation is 75 point while after implementation is 107 point. This has implications for better use for mitigate people in laboratory area, save time when looking for tools and materials, safe workplace, as well as improving the culture and spirit of ‘6S’ on staff due to better and safetier working environment.

  3. Dynamic axle and wheel loads identification: laboratory studies

    Science.gov (United States)

    Zhu, X. Q.; Law, S. S.

    2003-12-01

    Two methods have been reported by Zhu and Law to identify moving loads on the top of a bridge deck. One is based on the exact solution (ESM) and the other is based on the finite element formulation (FEM). Simulation studies on the effect of different influencing factors have been reported previously. This paper comparatively studies the performances of these two methods with experimental measurements obtained from a bridge/vehicle system in the laboratory. The strains of the bridge deck are measured when a model car moves across the bridge deck along different paths. The moving loads on the bridge deck are identified from the measured strains using these two methods, and the responses are reconstructed from the identified loads for comparison with the measured responses to verify the performances of these methods. Studies on the identification accuracy due to the effect of the number of vibration mode used, the number of measuring points and eccentricities of travelling paths are performed. Results show that the ESM could identify the moving loads individually or as axle loads when they are travelling at an eccentricity with the sensors located close to the travelling path of the forces. And the accuracy of the FEM is dependent on the amount of measured information used in the identification.

  4. Department of Energy multiprogram laboratories

    International Nuclear Information System (INIS)

    1982-09-01

    The Panel recommends the following major roles and missions for the laboratories: perform the Department's national trust fundamental research missions in the physical sciences, including high energy and nuclear physics, and the radiobiological sciences including nuclear medicine; sustain scientific staff core capabilities and specialized research facilities for laboratory research purposes and for use by other Federal agencies and the private sector; perform independent scientific and technical assessment or verification studies required by the Department; and perform generic research and development where it is judged to be in the public interest or where for economic or technical reasons industry does not choose to support it. Organizational efficiencies if implemented by the Department could contribute toward optimal performance of the laboratories. The Panel recommends that a high level official, such as a Deputy Under Secretary, be appointed to serve as Chief Laboratory Executive with authority to help determine and defend the research and development budget, to allocate resources, to decide where work is to be done, and to assess periodically laboratory performance. Laboratory directors should be given substantially more flexibility to deploy resources and to initiate or adapt programs within broad guidelines provided by the Department. The panel recommends the following actions to increase the usefulness of the laboratories and to promote technology transfer to the private sector: establish user groups for all major mission programs and facilities to ensure greater relevance for Department and laboratory efforts; allow the laboratories to do more reimbursable work for others (other Federal agencies, state and local governments, and industry) by relaxing constraints on such work; implement vigorously the recently liberalized patent policy; permit and encourage joint ventures with industry

  5. The Recording of Student Performance in the Microbiology Laboratory as a Training, Tutorial, and Motivational Tool

    Directory of Open Access Journals (Sweden)

    Steven M. Lipson

    2011-03-01

    Full Text Available The laboratory component of a microbiology course consists of exercises which mandate a level of proficiency and manual dexterity equal to and often beyond that recognized among other biology courses. Bacterial growth, maintenance, identification (e.g., Gram stain, biochemical tests, genomics, as well as the continuous need to maintain laboratory safety and sterile technique, are only a few skills/responsibilities critical to the discipline of microbiology. Performance of the Gram stain remains one of the most basic and pivotal skills that must be mastered in the microbiology laboratory. However, a number of students continually have difficulty executing the Gram stain and preparative procedures associated with the test. In order to address this issue, we incorporated real-time digital recording as a supplemental teaching aid in the microbiology laboratory. Our use of the digital movie camera in the teaching setting served to enhance interest, motivate students, and in general, improve student performance.

  6. Laboratory studies of fluid flow through borehole seals

    International Nuclear Information System (INIS)

    South, D.L.

    1983-01-01

    Boreholes in the vicinity of a nuclear waste repository must be reliably sealed to prevent rapid migration of radionuclide contaminated water from the vicinity of the repository to the accessible environment. Few data currently exist regarding the effectiveness of borehole sealing. The objective of this research was to assess the performance of borehole seals under laboratory conditions, particularly with regard to varying stress fields. The approach used to evaluate borehole seals was to compare flow through a sealed borehole with flow through intact rock. Granite, basalt, and tuff were tested, using either cement or bentonite as the seal material. The main conclusions reached as a result of the experiments is that currently existing materials are capable of forming high quality seals when placed under laboratory conditions. Variation of triaxial stress state about a borehole does not significantly affect seal performance if the rock is stiffer than the seal material. Temperature/moisture variations (drying) degraded the quality of cement seals significantly. Performance partially recovered upon resaturation. Significant remaining questions include field emplacement techniques; field vertification of plug quality; plug performance over long time periods, particularly with respect to temperature/moisture variations and chemical stability; and radionuclide sorption capabilities. Scale effects are also important, as shafts and drifts must be sealed as well as larger diameter boreholes

  7. Study on construction method of concrete in the underground research laboratory

    International Nuclear Information System (INIS)

    Iriya, Keshiro; Mikami, Tetsuji; Yasuoka, Tetsuji; Uegaki, Yoshiaki

    2001-05-01

    Although there are several types in low alkalinity cements, highly fly ash contained silicafume cement (HFSC) has been studied in JNC. It is demonstrated that pH of pore water of the cement indicates below 10.5 as results of other TRU study. However although chemical properties and basic mechanical behavior are well understood, workability so on in constructing is little investigated. Since the underground research laboratory plays a important role in investigating constructing technology, HFSC will be adopted for supporting rock cavern so on. It is required that workability of low alkalinity cements should be assessed. Major performance of workability in tunnel construction in rock will be investigated and R and D planning will be done toward the laboratory construction. Conclusion obtained in this study is described as followings. 1) As results of laboratory test, HFSC and LHHPC developed by AECL fulfil the requirements of shotcrete using by hardening accelerator with calcium-salpho-aluminate. It is concluded that HFSC and LHHPC can be applied for shotcrete. 2) The experiment upon corrosion of re-bars by facing saline water at a offshore is planned. 3) It is noted that pH decreases significantly with rise of silicafume content and that silicafume should be used as much as OPC. 4) It is investigated where the low alkalinity cement should be applied in a actual radio waste repository and R and D program in the laboratory is planned. (author)

  8. Personnel-dosimetry intercomparison studies at the Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Swaja, R.E.; Sims, C.S.

    1982-01-01

    Since 1974, seven annual personnel dosimetry intercomparison studies have been conducted at the Oak Ridge National Laboratory using the Health Physics Reactor. These studies have produced more than 2000 measurements by 72 participating organizations of neutron and gamma dose equivalents between 0.1 to 15.0 mSv in six mixed radiation fields. The relative performance of three basic types of personnel neutron dosimeters (nuclear emulsion film, thermoluminescent, and track-etch) and two basic types of gamma dosimeters (film and thermoluminescent) was assessed based on experimental results obtained during the seven intercomparisons

  9. Trackless tack coat materials : a laboratory evaluation performance acceptance.

    Science.gov (United States)

    2012-06-01

    The purpose of this study was to develop, demonstrate, and document laboratory procedures that could be used by the : Virginia Department of Transportation (VDOT) to evaluate non-tracking tack coat materials. The procedures would be used to : qualify...

  10. Beetroot Juice Improves On-Water 500 M Time-Trial Performance, and Laboratory-Based Paddling Economy in National and International-Level Kayak Athletes.

    Science.gov (United States)

    Peeling, Peter; Cox, Gregory R; Bullock, Nicola; Burke, Louise M

    2015-06-01

    We assessed the ingestion of a beetroot juice supplement (BR) on 4-min laboratory-based kayak performance in national level male (n = 6) athletes (Study A), and on 500 m on-water kayak time-trial (TT) performance in international level female (n = 5) athletes (Study B). In Study A, participants completed three laboratory-based sessions on a kayak ergometer, including a 7 × 4 min step test, and two 4 min maximal effort performance trials. Two and a half hours before the warm-up of each 4 min performance trial, athletes received either a 70 ml BR shot containing ~4.8 mmol of nitrate, or a placebo equivalent (BRPLA). The distance covered over the 4 min TT was not different between conditions; however, the average VO2 over the 4 min period was significantly lower in BR (p = .04), resulting in an improved exercise economy (p = .05). In Study B, participants completed two field-based 500 m TTs, separated by 4 days. Two hours before each trial, athletes received either two 70 ml BR shots containing ~9.6 mmol of nitrate, or a placebo equivalent (BRPLA). BR supplementation significantly enhanced TT performance by 1.7% (p = .01). Our results show that in national-level male kayak athletes, commercially available BR shots (70 ml) containing ~4.8 mmol of nitrate improved exercise economy during laboratory-based tasks predominantly reliant on the aerobic energy system. Furthermore, greater volumes of BR (140 ml; ~9.6 mmol nitrate) provided to international-level female kayak athletes resulted in enhancements to TT performance in the field.

  11. Prediction of practical performance in preclinical laboratory courses – the return of wire bending for admission of dental students in Hamburg

    Directory of Open Access Journals (Sweden)

    Kothe, Christian

    2014-05-01

    Full Text Available [english] Although some recent studies concluded that dexterity is not a reliable predictor of performance in preclinical laboratory courses in dentistry, they could not disprove earlier findings which confirmed the worth of manual dexterity tests in dental admission. We developed a wire bending test (HAM-Man which was administered during dental freshmen’s first week in 2008, 2009, and 2010. The purpose of our study was to evaluate if the HAM-Man is a useful selection criterion additional to the high school grade point average (GPA in dental admission. Regression analysis revealed that GPA only accounted for a maximum of 9% of students’ performance in preclinical laboratory courses, in six out of eight models the explained variance was below 2%. The HAM-Man incrementally explained up to 20.5% of preclinical practical performance over GPA. In line with findings from earlier studies the HAM-Man test of manual dexterity showed satisfactory incremental validity. While GPA has a focus on cognitive abilities, the HAM-Man reflects learning of unfamiliar psychomotor skills, spatial relationships, and dental techniques needed in preclinical laboratory courses. The wire bending test HAM-Man is a valuable additional selection instrument for applicants of dental schools.

  12. Exploring the links between quality assurance and laboratory resources. An audit-based study.

    Science.gov (United States)

    Singh, Navjeevan; Panwar, Aru; Masih, Vipin Fazal; Arora, Vinod K; Bhatia, Arati

    2003-01-01

    To investigate and rectify the problems related to Ziehl-Neelsen (Z-N) staining in a cytology laboratory in the context of quality assurance. An audit based quality assurance study of 1,421 patients with clinical diagnoses of tubercular lymphadenopathy who underwent fine needle aspiration cytology. Data from 8 months were audited (group 1). Laboratory practices related to selection of smears for Z-N staining were studied. A 2-step corrective measure based on results of the audit was introduced for 2 months (group 2). Results were subjected to statistical analysis using the chi 2 test. Of 1,172 patients in group 1,368 had diagnoses other than tuberculosis. Overall acid-fast bacillus (AFB) positivity was 42%. AFB positivity in 249 patients in group 2 was 89% (P assurance. Solving everyday problems can have far-reaching benefits for the performance of laboratory personnel, resources and work flow.

  13. Performance assessment of laboratory and field-scale multi-step passive treatment of iron-rich acid mine drainage for design improvement.

    Science.gov (United States)

    Rakotonimaro, Tsiverihasina V; Neculita, Carmen Mihaela; Bussière, Bruno; Genty, Thomas; Zagury, Gérald J

    2018-04-17

    Multi-step passive systems for the treatment of iron-rich acid mine drainage (Fe-rich AMD) perform satisfactorily at the laboratory scale. However, their field-scale application has revealed dissimilarities in performance, particularly with respect to hydraulic parameters. In this study, the assessment of factors potentially responsible for the variations in performance of laboratory and field-scale multi-step systems was undertaken. Three laboratory multi-step treatment scenarios, involving a combination of dispersed alkaline substrate (DAS) units, anoxic dolomitic drains, and passive biochemical reactors (PBRs), were set up in 10.7-L columns. The field-scale treatment consisted of two PBRs separated by a wood ash (WA) reactor. The parameters identified as possibly influencing the performances of the laboratory and field-scale experiments were the following: AMD chemistry (electrical conductivity and Fe and SO 4 2- concentrations), flow rate (Q), and saturated hydraulic conductivity (k sat ). Based on these findings, the design of an efficient passive multi-step treatment system is suggested to consider the following: (1) Fe pretreatment, using materials with high k sat and low HRT. If a PBR is to be used, the Fe load should be PBR/DAS filled with a mixture with at least 20% of neutralizing agent; (3) include Q and k sat (> 10 -3  cm/s) in the long-term prediction. Finally, mesocosm testing is strongly recommended prior to construction of full-scale systems for the treatment of Fe-rich AMD.

  14. Performance goals on simulators boost resident motivation and skills laboratory attendance.

    Science.gov (United States)

    Stefanidis, Dimitrios; Acker, Christina E; Greene, Frederick L

    2010-01-01

    To assess the impact of setting simulator training goals on resident motivation and skills laboratory attendance. Residents followed a proficiency-based laparoscopic curriculum on the 5 Fundamentals of Laparoscopic Surgery and 9 virtual reality tasks. Training goals consisted of the average expert performance on each task + 2 SD (mandatory) and best expert performance (optional). Residents rated the impact of the training goals on their motivation on a 20-point visual analog scale. Performance and attendance data were analyzed and correlated (Spearman's). Data are reported as medians (range). General Surgery residency program at a regional referral Academic Medical Center. General surgery residents (n = 15). During the first 5 months of the curriculum, weekly attendance rate was 51% (range, 8-96). After 153 (range, 21-412) repetitions, resident speed improved by 97% (range, 18-230), errors improved by 17% (range, 0-24), and motion efficiency by 59% (range, 26-114) compared with their baseline. Nine (60%) residents achieved proficiency in 7 (range, 3-14) and the best goals in 3.5 (range, 1-9) tasks; the other 6 residents had attendance rates motivation as 15 (range, 1-18) and setting a best goal as 13 (range, 1-18). Motivation ratings correlated positively with attendance rates, number of repetitions, performance improvement, and achievement of proficiency and best goals (r = 0.59-0.75; p motivation to participate in a simulator curriculum. While more stringent goals may potentiate this effect, they have a limited impact on senior residents. Further research is needed to investigate ways to improve skills laboratory attendance. Copyright 2010 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  15. Cold Climate Foundation Retrofit Experimental Hygrothermal Performance. Cloquet Residential Research Facility Laboratory Results

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Louise F. [NorthernSTAR, St. Paul, MN (United States); Harmon, Anna C. [NorthernSTAR, St. Paul, MN (United States)

    2015-04-09

    This project was funded jointly by the National Renewable Energy Laboratory (NREL) and Oak Ridge National Laboratory (ORNL). ORNL focused on developing a full basement wall system experimental database to enable others to validate hygrothermal simulation codes. NREL focused on testing the moisture durability of practical basement wall interior insulation retrofit solutions for cold climates. The project has produced a physically credible and reliable long-term hygrothermal performance database for retrofit foundation wall insulation systems in zone 6 and 7 climates that are fully compliant with the performance criteria in the 2009 Minnesota Energy Code. These data currently span the period from November 10, 2012 through May 31, 2014 and are anticipated to be extended through November 2014. The experimental data were configured into a standard format that can be published online and that is compatible with standard commercially available spreadsheet and database software.

  16. laboratory activities and students practical performance

    African Journals Online (AJOL)

    unesco

    as necessary and important, very little justification was given for their .... Chemistry laboratory activities refer to the practical activities which students ..... equations, formulae, definitions, terminology, physical properties, hazards or disposal.

  17. Case Studies in Sustainability Used in an Introductory Laboratory Course to Enhance Laboratory Instruction

    Science.gov (United States)

    Luster-Teasley, Stephanie; Hargrove-Leak, Sirena; Gibson, Willietta; Leak, Roland

    2017-01-01

    This educational research seeks to develop novel laboratory modules by using Case Studies in the Science Teaching method to introduce sustainability and environmental engineering laboratory concepts to 21st century learners. The increased interest in "going green" has led to a surge in the number of engineering students studying…

  18. The effect of noise in a performance measure on work motivation: A real effort laboratory experiment

    NARCIS (Netherlands)

    Sloof, R.; van Praag, C.M.

    2008-01-01

    This paper reports the results of an individual real effort laboratory experiment where subjects are paid for measured performance. Measured performance equals actual performance plus noise. We compare a stable environment where the noise is small with a volatile environment where the noise is

  19. The effect of noise in a performance measure on work motivation: A real effort laboratory experiment

    NARCIS (Netherlands)

    Sloof, R.; van Praag, C.M.

    2010-01-01

    This paper reports the results of an individual real effort laboratory experiment where subjects are paid for measured performance. Measured performance equals actual performance plus noise. We compare a stable environment where the noise is small with a volatile environment where the noise is

  20. Hideout of sea water impurities in steam generator tube deposits: laboratory and field studies

    International Nuclear Information System (INIS)

    Balakrishnan, P.V.; Turner, C.W.; Thompson, R.; Sawochka, S.

    1996-01-01

    Sea water impurities hide out within thin (∼10 μm) deposits on steam generator tubes, as demonstrated by both laboratory studies using segments of fouled steam generator tubes pulled in 1992 from Crystal River-3 nuclear power station and field hideout return studies performed during recent plant shutdowns. Laboratory tests performed at 279 o C (534 o F) and heat fluxes ranging from 35 to 114 kW/m 2 (11,100 - 36,150 Btu/h.ft 2 ), conditions typical of the lower tubesheet to the first support plate region of a once-through steam generator, showed that impurity hideout can occur in thin free-span tube deposits. The extent of hideout increased with increasing heat flux. Soluble species, such as sodium and chloride ions, returned promptly to the bulk water from the deposits when the heat flux was turned off, whereas less soluble species, such as calcium sulfate and magnesium hydroxide, returned more slowly. Recent field hideout return studies performed at Crystal River-3 where the water level in the steam generators was maintained below the first tube support plate during the shutdown, thus wetting only the thin deposits in the free span and the small sludge pile, corroborate the laboratory findings, showing that hideout does indeed occur in the free-span regions of the tubes. These findings suggest that hideout within tube deposits has to be accounted for in the calculation of crevice chemistry from hideout return studies and in controlling the bulk chemistry using the molar ratio criterion. (author). 3 refs., 4 tabs., 3 figs

  1. Leaching of wood ash - Laboratory and field studies; Lakning av vedaska - Laboratorie- och faeltstudier

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, Per-Erik

    2012-02-15

    High forest production leads to diminishing amounts of base cations and micro nutrients in forest soils. This is due to uptake in, and harvest of, the trees. Losses can be compensated for by spreading stabilized wood ash on the forest ground, which means recycling of base cations and micro nutrients. Chemical composition of wood ash can easily be described by standard methods in the laboratory. However, this does not include the process of leaching in nature, such as which components and leaching rate for different compounds. During field conditions several factors are added, which are not available in the laboratory. After almost 10 years in the forest soils there still remains large quantities of the original product. Only 10-30 % of the wood ash products and 5 % of the lime product has been leached. In the laboratory study the leached amount was slightly larger, at the most 35 % for wood ash and 20 % for lime. Both studies indicate long time for weathering of the products in forest soils. Slower leaching rate from pellets of wood ash compared to leaching rate from crushed wood ash in the laboratory study is not verified by the field study. This indicates limited possibilities to control rates of leaching in the environment

  2. Nanotechnology Characterization Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Nanotechnology Characterization Laboratory (NCL) at the Frederick National Laboratory for Cancer Research performs preclinical characterization of nanomaterials...

  3. Diffusion of Radionuclides in Bentonite Clay - Laboratory and in situ Studies

    International Nuclear Information System (INIS)

    Jansson, Mats

    2002-12-01

    This thesis deals with the diffusion of ions in compacted bentonite clay. Laboratory experiments were performed to examine in detail different processes that affect the diffusion. To demonstrate that the results obtained from the laboratory investigations are valid under in situ conditions, two different kinds of in situ experiments were performed. Laboratory experiments were performed to better understand the impact of ionic strength on the diffusion of S 2+ and Cs + ions, which sorb to mineral surfaces primarily by ion exchange. Furthermore, surface related diffusion was examined and demonstrated to take place for Sr 2+ and Cs + but not for Co 2+ , which sorbs on mineral surfaces by complexation. The diffusion of anions in bentonite clay compacted to different dry densities was also investigated. The results indicate that anion diffusion in bentonite clay consists of two processes, one fast and another slower. We ascribe the fast diffusive process to intralayer diffusion and the slow process to diffusion in interparticle water, where anions are to some extent sorbed to edge sites of the montmorillonite. Two different types of in situ experiments were performed, CHEMLAB and LOT. CHEMLAB is a borehole laboratory, where cation (Cs + , Sr 2+ and Co 2+ ) and anion (I- and TcO 4 - ) diffusion experiments were performed using groundwater from a fracture in the borehole. In the LOT experiments cylindrical bentonite blocks surrounding a central copper rod were placed in a 4 m deep vertical borehole. The borehole was then sealed and the blocks are left for 1, 5 or >> 5 years. When the bentonite was water saturated the central copper rod is heated to simulate the temperature increase due to radioactive decay of the spent fuel. Bentonite doped with radioactive Cs and Co was placed in one of the lower blocks. Interestingly, the redox-sensitive pertechnetate ion (TcO 4 - ) which thermodynamically should be reduced and precipitate as TcO 2 n H 2 O, travelled unreduced through

  4. The influence of uncertainties of measurements in laboratory performance evaluation using an intercomparison program of radionuclide assays in environmental samples

    International Nuclear Information System (INIS)

    Tauhata, Luiz; Elizabeth Couto Machado Vianna, Maria; Eduardo de Oliveira, Antonio; Cristina de Melo Ferreira, Ana; Julia Camara da Silva Braganca, Maura; Faria Clain, Almir

    2006-01-01

    To show the influence of measurement uncertainties in performance evaluation of laboratories, data from 42 comparison runs were evaluated using two statistical criteria. The normalized standard deviation, D, used by US EPA, that mainly takes into account the accuracy, and the normalized deviation, E, that includes the individual laboratory uncertainty used for performance evaluation in the key-comparisons by BIPM. The results show that data evaluated by the different criteria give a significant deviation of laboratory performance in each radionuclide assay when we analyse a large quantity of data

  5. Laboratory and Feasibility Study for Industrial Wastewater Effluents Treatment by Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Zimek, Z.; Głuszewski, W. [Centre for Radiation Research and Technology, Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    2012-07-01

    The study of wastewater treatment by radiation regarding chemical processes contribution and physical-chemical separation of highly concentrated non-organic pollutants deposited in specific industrial waste are proposed. Laboratory stand should be build and the study should be performed to confirm possible mechanism of the sedimentation process of nonorganic pollutants during separation initiated by ionizing radiation. Evaluation from technical and economical point of view of this specific radiation technology and feasibility study preparation for industrial facility will be the main output at the final stage of the project. (author)

  6. Laboratory and Feasibility Study for Industrial Wastewater Effluents Treatment by Radiation

    International Nuclear Information System (INIS)

    Zimek, Z.; Głuszewski, W.

    2012-01-01

    The study of wastewater treatment by radiation regarding chemical processes contribution and physical-chemical separation of highly concentrated non-organic pollutants deposited in specific industrial waste are proposed. Laboratory stand should be build and the study should be performed to confirm possible mechanism of the sedimentation process of nonorganic pollutants during separation initiated by ionizing radiation. Evaluation from technical and economical point of view of this specific radiation technology and feasibility study preparation for industrial facility will be the main output at the final stage of the project. (author)

  7. Team-based learning in the gross anatomy laboratory improves academic performance and students' attitudes toward teamwork.

    Science.gov (United States)

    Huitt, Tiffany W; Killins, Anita; Brooks, William S

    2015-01-01

    As the healthcare climate shifts toward increased interdisciplinary patient care, it is essential that students become accomplished at group problem solving and develop positive attitudes toward teamwork. Team-based learning (TBL) has become a popular approach to medical education because of its ability to promote active learning, problem-solving skills, communication, and teamwork. However, its documented use in the laboratory setting and physical therapy education is limited. We used TBL as a substitute for one-third of cadaveric dissections in the gross anatomy laboratories at two Doctor of Physical Therapy programs to study its effect on both students' perceptions and academic performance. We surveyed students at the beginning and completion of their anatomy course as well as students who had previously completed a traditional anatomy course to measure the impact of TBL on students' perceptions of teamwork. We found that the inclusion of TBL in the anatomy laboratory improves students' attitudes toward working with peers (P < 0.01). Non-TBL students had significantly lower attitudes toward teamwork (P < 0.01). Comparison of academic performance between TBL and non-TBL students revealed that students who participated in TBL scored significantly higher on their first anatomy practical examination and on their head/neck written examination (P < 0.001). When asked to rate their role in a team, a 10.5% increase in the mean rank score for Problem Solver resulted after the completion of the TBL-based anatomy course. Our data indicate that TBL is an effective supplement to cadaveric dissection in the laboratory portion of gross anatomy, improving both students' grades and perceptions of teamwork. © 2014 American Association of Anatomists.

  8. Radiation carcinogenesis, laboratory studies

    International Nuclear Information System (INIS)

    Shellabarger, C.J.

    1974-01-01

    Laboratory studies on radioinduced carcinogenesis are reviewed. Some topics discussed are: radioinduced neoplasia in relation to life shortening; dose-response relationships; induction of skin tumors in rats by alpha particles and electrons; effects of hormones on tumor response; effects of low LET radiations delivered at low dose-rates; effects of fractionated neutron radiation; interaction of RBE and dose rate effects; and estimates of risks for humans from animal data. (U.S.)

  9. Effects of cadmium on the performance and microbiology of laboratory-scale lagoons treating domestic sewage.

    Science.gov (United States)

    Bonnet, J L; Bohatier, J; Pépin, D

    1999-06-01

    Two experiments were performed to assess the impact of cadmium on the sewage lagoon wastewater treatment process. For each one, three laboratory-scale pilot plants with one tank receiving the same raw effluent were used; one plant served as control and the other two were contaminated once only with cadmium. In the first study, the effects of a shock load of two concentrations of cadmium chloride (60 and 300 micrograms/l) on the plant performance, microbial populations (protists and bacteria) and enzyme activities were determined. Initially, most of the performance parameters were affected concentration-dependently. A reduction in the protist population density and some influence on the total bacterial population were observed, and the potential enzymatic activities were also modified. A second experiment with a lower cadmium concentration (30 micrograms/l), supplied as chloride or sulphate, still perturbed most of the parameters studied, and the effects of the two cadmium salts were identical.

  10. PEER Testbed Study on a Laboratory Building: Exercising Seismic Performance Assessment

    OpenAIRE

    Comerio, Mary C.; Stallmeyer, John C.; Smith, Ryan; Makris, Nicos; Konstantinidis, Dimitrios; Mosalam, Khalid; Lee, Tae-Hyung; Beck, James L.; Porter, Keith A.; Shaikhutdinov, Rustem; Hutchinson, Tara; Chaudhuri, Samit Ray; Chang, Stephanie E.; Falit-Baiamonte, Anthony; Holmes, William T.

    2005-01-01

    From 2002 to 2004 (years five and six of a ten-year funding cycle), the PEER Center organized the majority of its research around six testbeds. Two buildings and two bridges, a campus, and a transportation network were selected as case studies to “exercise” the PEER performance-based earthquake engineering methodology. All projects involved interdisciplinary teams of researchers, each producing data to be used by other colleagues in their research. The testbeds demonstrat...

  11. Idaho National Laboratory Quarterly Performance Analysis - 3rd Quarter FY2014

    Energy Technology Data Exchange (ETDEWEB)

    Lisbeth A. Mitchell

    2014-09-01

    This report is published quarterly by the Idaho National Laboratory (INL) Performance Assurance Organization. The Department of Energy (DOE) Occurrence Reporting and Processing System (ORPS), as prescribed in DOE Order 232.2, “Occurrence Reporting and Processing of Operations Information,” requires a quarterly analysis of events, both reportable and not reportable, for the previous 12 months. This report is the analysis of occurrence reports and other non-reportable issues identified at INL from July 2013 through June 2014.

  12. Highlighting High Performance: National Renewable Energy Laboratory's Visitors Center, Golden, Colorado

    International Nuclear Information System (INIS)

    Burgert, S.

    2001-01-01

    The National Renewable Energy Laboratory Visitors Center, also known as the Dan Schaefer Federal Building, is a high-performance building located in Golden, Colorado. The 6,400-square-foot building incorporates passive solar heating, energy-efficient lighting, an evaporative cooling system, and other technologies to minimize energy costs and environmental impact. The Visitors Center displays a variety of interactive exhibits on energy efficiency and renewable energy, and the building includes an auditorium, a public reading room, and office space

  13. Online general pre-laboratory training course for facilitating first year chemical laboratory use

    Directory of Open Access Journals (Sweden)

    Maria Limniou

    2010-03-01

    Full Text Available In Chemistry, practical work is a highly demanding process in which students should be well-prepared before and alert during,laboratory sessions. Various general difficulties such as the limited laboratory time and the lack of connections between theoryand practicals often do not allow students to actively participate in the learning process. The aim of this investigation is to studyhow an online general pre-laboratory training course inspired by cognitive load theory influenced the teaching of first yearchemistry students engaged in laboratory work. Two different groups of chemistry students (experimental group (EG andcontrol group (CG from the University of Manchester participated in this investigation. The EG group participated in the onlinepre-laboratory course before entering the laboratory, while the CG group performed the experiments following the traditionalteaching procedure. The comparison of students’ responses to the same assessments of fundamental chemical and basiclaboratory knowledge showed that overall the performance of the EG group of students was higher than that of the CGstudents. Overall, the EG students valued the opportunity to have an online training course. By creating a flexible learningenvironment which included animations, simulations and self-assessments, the general laboratory difficulties were overcome.These interactive learning features gave students the opportunity to engage in independent study, by which restrictions of timeand place were overcome.

  14. To what extent is clinical and laboratory information used to perform medication reviews in the nursing home setting? the CLEAR study

    Directory of Open Access Journals (Sweden)

    Mestres Gonzalvo C

    2015-05-01

    Full Text Available Carlota Mestres Gonzalvo,1 Kim PGM Hurkens,2 Hugo AJM de Wit,3 Brigit PC van Oijen,1 Rob Janknegt,1 Jos MGA Schols,4 Wubbo J Mulder,5 Frans R Verhey,6 Bjorn Winkens,7 Paul-Hugo M van der Kuy1 1Department of Clinical Pharmacology and Toxicology, Orbis Medical Centre, Sittard, 2Department of Internal Medicine, Section of Geriatric Medicine, Academic Medical Centre, Amsterdam, 3Department of Clinical Pharmacy and Toxicology, Atrium Medical Centre, Heerlen, 4Department of Family Medicine and Department of Health Services Research, School for Public Health and Primary Care, Maastricht University, 5Department of Internal Medicine, Maastricht University Medical Centre, 6Department of Psychiatry and Neuropsychology, Alzheimer Centre Limburg/School for Mental Health and Neurosciences, 7Department of Methodology and Statistics, School for Public Health and Primary Care, Maastricht University, Maastricht, the Netherlands Background: The aim of this study was to evaluate to what extent laboratory data, actual medication, medical history, and/or drug indication influence the quality of medication reviews for nursing home patients. Methods: Forty-six health care professionals from different fields were requested to perform medication reviews for three different cases. Per case, the amount of information provided varied in three subsequent stages: stage 1, medication list only; stage 2, adding laboratory data and reason for hospital admission; and stage 3, adding medical history/drug indication. Following a slightly modified Delphi method, a multidisciplinary team performed the medication review for each case and stage. The results of these medication reviews were used as reference reviews (gold standard. The remarks from the participants were scored, according to their potential clinical impact, from relevant to harmful on a scale of 3 to -1. A total score per case and stage was calculated and expressed as a percentage of the total score from the expert

  15. Standardization of 8-color flow cytometry across different flow cytometer instruments: A feasibility study in clinical laboratories in Switzerland.

    Science.gov (United States)

    Glier, Hana; Heijnen, Ingmar; Hauwel, Mathieu; Dirks, Jan; Quarroz, Stéphane; Lehmann, Thomas; Rovo, Alicia; Arn, Kornelius; Matthes, Thomas; Hogan, Cassandra; Keller, Peter; Dudkiewicz, Ewa; Stüssi, Georg; Fernandez, Paula

    2017-07-29

    The EuroFlow Consortium developed a fully standardized flow cytometric approach from instrument settings, through antibody panel, reagents and sample preparation protocols, to data acquisition and analysis. The Swiss Cytometry Society (SCS) promoted a study to evaluate the feasibility of using such standardized measurements of 8-color data across two different flow cytometry platforms - Becton Dickinson (BD) FACSCanto II and Beckman Coulter (BC) Navios, aiming at increasing reproducibility and inter-laboratory comparability of immunophenotypic data in clinical laboratories in Switzerland. The study was performed in two phases, i.e. a learning phase (round 1) and an analytical phase (rounds 2 and 3) consisting of a total of three rounds. Overall, 10 laboratories using BD FACSCanto II (n=6) or BC Navios (n=4) flow cytometers participated. Each laboratory measured peripheral blood samples from healthy donors stained with a uniform antibody panel of reagents - EuroFlow Lymphoid Screening Tube (LST) - applying the EuroFlow standardized protocols for instrument setup and sample preparation (www.EuroFlow.org). All data files were analyzed centrally and median fluorescence intensity (MedFI) values for individual markers on defined lymphocyte subsets were recorded; variability from reference MedFI values was assessed using performance scores. Data troubleshooting and discussion of the results with the participants followed after each round at SCS meetings. The results of the learning phase demonstrated that standardized instrument setup and data acquisition are feasible in routine clinical laboratories without previous experience with EuroFlow. During the analytical phase, highly comparable data were obtained at the different laboratories using either BD FACSCanto II or BC Navios. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%. In the last study round, 89% of participants scored over 90% MedFI values within the acceptance criteria

  16. Radiation and Health Technology Laboratory Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Goles, Ronald W.; Johnson, Michelle Lynn; Piper, Roman K.; Peters, Jerry D.; Murphy, Mark K.; Mercado, Mike S.; Bihl, Donald E.; Lynch, Timothy P.

    2003-07-15

    The Radiological Standards and Calibrations Laboratory, a part of Pacific Northwest National Laboratory (PNNL)(a) performs calibrations and upholds reference standards necessary to maintain traceability to national standards. The facility supports U.S. Department of Energy (DOE) programs at the Hanford Site, programs sponsored by DOE Headquarters and other federal agencies, radiological protection programs at other DOE and commercial nuclear sites and research and characterization programs sponsored through the commercial sector. The laboratory is located in the 318 Building of the Hanford Site's 300 Area. The facility contains five major exposure rooms and several laboratories used for exposure work preparation, low-activity instrument calibrations, instrument performance evaluations, instrument maintenance, instrument design and fabrication work, thermoluminescent and radiochromic Dosimetry, and calibration of measurement and test equipment (M&TE). The major exposure facilities are a low-scatter room used for neutron and photon exposures, a source well room used for high-volume instrument calibration work, an x-ray facility used for energy response studies, a high-exposure facility used for high-rate photon calibration work, a beta standards laboratory used for beta energy response studies and beta reference calibrations and M&TE laboratories. Calibrations are routinely performed for personnel dosimeters, health physics instrumentation, photon and neutron transfer standards alpha, beta, and gamma field sources used throughout the Hanford Site, and a wide variety of M&TE. This report describes the standards and calibrations laboratory.

  17. The Horonobe Underground Research Laboratory (Tentative name) Project. A program on survey and research performed from earth surface

    International Nuclear Information System (INIS)

    2001-03-01

    The Horonobe Underground Research Laboratory (Tentative name) Project under planning at Horonobe-machi by the Japan Nuclear Cycle Development Institute (JNC) is a research facility on deep underground shown in the Long-term program on research, development and application of nuclear energy (June, 1994)' (LPNE), where some researches on the deep underground targeted at sedimentary rocks are carried out. The plan on The Horonobe Underground Research Laboratory performed at Horonobe-machi' is an about 20 years plan ranging from beginning to finishing of its survey and research, which is carried out by three steps such as 'Survey and research performed from earth surface', 'Survey and research performed under excavation of road', and Survey and research performed by using the road'. The Horonobe Underground Research Laboratory is one of research facilities on deep underground shown its importance in LPNE, and carries out some researches on the deep underground at a target of the sedimentary rocks. And also The Horonobe Underground Research Laboratory confirms some technical reliability and support on stratum disposal shown in the 'Technical reliability on stratum disposal of the high level radioactive wastes. The Second Progress Report of R and D on geological disposal' summarized on November, 1999 by JNC through actual tests and researches at the deep stratum. The obtained results are intended to reflect to disposal business of The Horonobe Underground Research Laboratory and safety regulation and so on performed by the government, together with results of stratum science research, at the Tono Geoscience Center, of geological disposal R and D at the Tokai Works, or of international collaborations. For R and D at the The Horonobe Underground Research Laboratory after 2000, following subjects are shown: 1) Survey technique on long-term stability of geological environment, 2) Survey technique on geological environment, 3) Engineering technique on engineered barrier and

  18. [Comparability study of analytical results between a group of clinical laboratories].

    Science.gov (United States)

    Alsius-Serra, A; Ballbé-Anglada, M; López-Yeste, M L; Buxeda-Figuerola, M; Guillén-Campuzano, E; Juan-Pereira, L; Colomé-Mallolas, C; Caballé-Martín, I

    2015-01-01

    To describe the study of the comparability of the measurements levels of biological tests processed in biochemistry in Catlab's 4 laboratories. Quality requirements, coefficients of variation and total error (CV% and TE %) were established. Controls were verified with the precision requirements (CV%) in each test and each individual laboratory analyser. Fresh serum samples were used for the comparability study. The differences were analysed using a Microsoft Access® application that produces modified Bland-Altman plots. The comparison of 32 biological parameters that are performed in more than one laboratory and/or analyser generated 306 Bland-Altman graphs. Of these, 101 (33.1%) fell within the accepted range of values based on biological variability, and 205 (66.9%) required revision. Data were re-analysed based on consensus minimum specifications for analytical quality (consensus of the Asociación Española de Farmacéuticos Analistas (AEFA), the Sociedad Española de Bioquímica Clínica y Patología Molecular (SEQC), the Asociación Española de Biopatología Médica (AEBM) and the Sociedad Española de Hematología y Hemoterapia (SEHH), October 2013). With the new specifications, 170 comparisons (56%) fitted the requirements and 136 (44%) required additional review. Taking into account the number of points that exceeded the requirement, random errors, range of results in which discrepancies were detected, and range of clinical decision, it was shown that the 44% that required review were acceptable, and the 32 tests were comparable in all laboratories and analysers. The analysis of the results showed that the consensus requirements of the 4 scientific societies were met. However, each laboratory should aim to meet stricter criteria for total error. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.

  19. Idaho National Laboratory Quarterly Performance Analysis - 2nd Quarter FY2014

    Energy Technology Data Exchange (ETDEWEB)

    Lisbeth A. Mitchell

    2014-06-01

    This report is published quarterly by the Idaho National Laboratory (INL) Performance Assurance Organization. The Department of Energy Occurrence Reporting and Processing System (ORPS), as prescribed in DOE Order 232.2, “Occurrence Reporting and Processing of Operations Information,” requires a quarterly analysis of events, both reportable and not reportable, for the previous 12 months. This report is the analysis of occurrence reports and other deficiency reports (including not reportable events) identified at INL from January 2014 through March 2014.

  20. LABORATORY EVALUATION ON PERFORMANCE OF GLASS FIBER REINFORCED PLASTIC MORTAR PIPE CULVERTS

    Directory of Open Access Journals (Sweden)

    Huawang Shi

    2018-04-01

    Full Text Available This paper investigated the performance and behaviour of glass fiber reinforced plastic mortar (FRPM pipes under different loading conditions. FRPM pipes with inner diameter of 1500 mm were prefabricated in factory. Mechanics performance testing (ring and axial compressive strength and elastic modulus, stiffness and fatigue test were carried out in laboratory. Ring stiffness test provided pipe stiffness (PS which is a function of geometry and material type of pipe through parallel plate loading test (PPLT. The fatigue test and micro-structure measure method were used to evaluate the durability effects of FRPM under repeated compression load. Results indicated that FRPM pipes had better mechanic performances as the road culverts under soils. It may be helpful for the design and construction of FRPM culverts.

  1. Laboratory and field evaluation of the impact of exercise on the performance of regular and polymer-based deet repellents.

    Science.gov (United States)

    Schofield, Steven; Tepper, Martin; Gadawski, Randy

    2007-11-01

    Studies were done in Manitoba, Canada, to evaluate the impact of exercise on repellent performance against mosquitoes. Two products containing the active ingredient N,N-diethyl-3-methylbenzamide (deet) were tested; one product was a polymer-based cream (3M Ultrathon Insect Repellent) and the other product was an alcohol-based pump spray formulation (Muskol Insect Repellent). Assessments were done in the laboratory using Aedes aegypti (L.) and in the field with naturally occurring populations of mosquitoes. Repellent was applied to the forearms (laboratory) or a lower leg (field) of test subjects at 1.5 g of test product per 600 cm2 surface area (0.75 or 0.83 mg deet/cm2). For a given test day, subjects exercised or did not. Exposure to mosquito attack was for 1 min at 30-min intervals in laboratory procedures, and it was continuous in field tests. Performance was measured as complete protection time (CPT). Moderate levels of physical activity resulted in a >40% decline in mean CPT, from 468 to 267 min in the laboratory experiments and from 359 to 203 min in field tests. Repellent product did not affect the magnitude of the decline. Mean biting pressure during field trials was 21.3 bites per min, and mosquito collections were made up primarily of Ochlerotatus sticticus (Meigen) and Aedes vexans (Meigen).

  2. Inter-laboratory comparison study of gamma cameras in Pakistan

    International Nuclear Information System (INIS)

    Shahid, M.A.; Mumtaz-ul-Haq

    1988-01-01

    The evaluation of the performance of both instrument and the physician are important in any quality assurance programme in nuclear medicine imaging. The IAEA launched a similar program in 1984 under its Regional Cooperation Agreement program in South Asian Countries. The first part of the study consisted of the evaluation of imaging equipment by imaging IAEA-WHO Simulated Anatomic Liver Phantom (SALP) and its interpretation by the physician. From Pakistan, 8 gamma cameras from 7 laboratories were used for the study and 16 physician interpreted in the SALP images. This paper reports the results of SALP images from Pakistan and shows the efficacy of 80 to 100% as regards the quality of image obtained and the interpretation done by the physicians. (author)

  3. Equipment and performance of the Q3D spectrometer installed at the tandem laboratory of Saclay

    International Nuclear Information System (INIS)

    Berthier, B.

    1979-01-01

    A quadrupole - dipole - dipole - dipole (Q3D) magnetic spectrometer with proportional gas counter which has been installed at the tandem laboratory of Saclay is described. Typical results are given indicating the performance of the apparatus in studies of heavy ion reactions at tandem energies for which good energy resolution and large solid angles are required. Improvements to allow the detection of heavier masses and less energetic ions with better energy resolution are planned. (U.K.)

  4. A 2-year study of patient safety competency assessment in 29 clinical laboratories.

    Science.gov (United States)

    Reed, Robyn C; Kim, Sara; Farquharson, Kara; Astion, Michael L

    2008-06-01

    Competency assessment is critical for laboratory operations and is mandated by the Clinical Laboratory Improvement Amendments of 1988. However, no previous reports describe methods for assessing competency in patient safety. We developed and implemented a Web-based tool to assess performance of 875 laboratory staff from 29 laboratories in patient safety. Question categories included workplace culture, categorizing error, prioritization of patient safety interventions, strength of specific interventions, and general patient safety concepts. The mean score was 85.0%, with individual scores ranging from 56% to 100% and scores by category from 81.3% to 88.6%. Of the most difficult questions (laboratory technologists. Computer-based competency assessments help laboratories identify topics for continuing education in patient safety.

  5. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China.

    Science.gov (United States)

    Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo

    2015-01-01

    To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479/1307), 38% (228/598), and 36% (449/1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them.

  6. Investigating Student Perceptions of the Chemistry Laboratory and Their Approaches to Learning in the Laboratory

    Science.gov (United States)

    Berger, Spencer Granett

    This dissertation explores student perceptions of the instructional chemistry laboratory and the approaches students take when learning in the laboratory environment. To measure student perceptions of the chemistry laboratory, a survey instrument was developed. 413 students responded to the survey during the Fall 2011 semester. Students' perception of the usefulness of the laboratory in helping them learn chemistry in high school was related to several factors regarding their experiences in high school chemistry. Students' perception of the usefulness of the laboratory in helping them learn chemistry in college was also measured. Reasons students provided for the usefulness of the laboratory were categorized. To characterize approaches to learning in the laboratory, students were interviewed midway through semester (N=18). The interviews were used to create a framework describing learning approaches that students use in the laboratory environment. Students were categorized into three levels: students who view the laboratory as a requirement, students who believe that the laboratory augments their understanding, and students who view the laboratory as an important part of science. These categories describe the types of strategies students used when conducting experiments. To further explore the relationship between students' perception of the laboratory and their approaches to learning, two case studies are described. These case studies involve interviews in the beginning and end of the semester. In the interviews, students reflect on what they have learned in the laboratory and describe their perceptions of the laboratory environment. In order to encourage students to adopt higher-level approaches to learning in the laboratory, a metacognitive intervention was created. The intervention involved supplementary questions that students would answer while completing laboratory experiments. The questions were designed to encourage students to think critically about the

  7. Comparative study of bedside and laboratory measurements of hemoglobin.

    Science.gov (United States)

    Krenzischek, D A; Tanseco, F V

    1996-11-01

    The purpose of this study was to examine the effects of variations in technique on measurements of hemoglobin level done at the bedside and to compare these results with laboratory measurements of hemoglobin. In accordance with hospital policy, procedure, and protocol, various techniques were used to obtain samples of capillary and venous blood and of blood from arterial and central venous catheters. Levels of hemoglobin were measured at the bedside and in the laboratory, and the results were compared. The Johns Hopkins Hospital adult postanesthesia care unit. A total of 187 blood samples were obtained from 62 adults who had undergone general surgery. Group I comprised 20 subjects with capillary and venous blood samples. Group II comprised 21 subjects with arterial blood samples. Group III comprised 21 subjects with central venous blood samples. The results showed that the amount of blood to be discarded before obtaining samples of arterial and central venous blood need not be any larger than double the dead space of the catheter, and that shaking the blood sample for 10 seconds was sufficient to mix the sample before measurement of hemoglobin levels. Results of bedside and laboratory measurements of hemoglobin level were comparable. Bedside measurement of hemoglobin increases efficiency in patient care, decreases risk of blood-transmitted infection for staff, and decreases cost to the patient. However, the persons who perform the assay must be responsible in adhering to the standard of practice to minimize errors in the measurements.

  8. Oil water laboratory

    International Nuclear Information System (INIS)

    P Junior, Oswaldo A.; Verli, Fernando; Lopes, Humberto E.

    2000-01-01

    Usually, the oily water effluent from petroleum processes needs to be treated prior to its environment discard and/or reuse. The synthesis of such water effluent residues in an Oily Water Laboratory - equipped with Water Treatment Pilot Scale Units - is fundamental to the study and effectiveness comparison among the typical industrial water treatment processes. The Oily Water Laboratory will allow the reproduction - in a small scale - of any oily water effluent produced in the industrial PETROBRAS units - such reproduction can be obtained by using the same fluids, oily concentration, salinity, process temperature, particle size distribution etc. Such Laboratory also allows the performance analysis of typical industrial equipment used throughout the water treatment schemes (e.g., hydro-cyclones), resulting in design and/or operational guidelines for these industrial scale schemes. In the particular niche of very small diameter oil droplet removal, more efficient and non-conventional schemes - such as centrifuges and/or membrane filtration - will be also studied in the Laboratory. In addition, the Laboratory shall be used in the certification of in-line oily water analyzers (e.g., TOC - Total Organic Carbon and OWC - Oil Wax Content). This paper describes the characteristics of such Laboratory and its main operational philosophy. (author)

  9. A Comparative Study of Melanin Content and Skin Morphology for Three Commonly Used Laboratory Swine (Sus scrofa domestica)

    Science.gov (United States)

    2012-09-01

    Air Force Research Laboratory 711th Human Performance Wing Human Effectiveness Directorate Bioeffects Division Optical Radiation Bioeffects...Branch AFRL-RH-FS-TR-2013-0004 A Comparative Study of Melanin Content and Skin Morphology for Three Commonly Used Laboratory Swine (Sus scrofa...Jindra Human Effectiveness Directorate Directed Energy Bioeffects Division Optical Radiation Branch Robert W. Kornegay Rick Figueroa Human

  10. Intervention of hydrogen analysis laboratory for radioactive materials study

    International Nuclear Information System (INIS)

    Bruno, N.; Vinces, H.; Figueroa, S.

    1996-01-01

    The objective of the practice was the measurement of the hydrogen concentration on structural material from the Central Nuclear Atucha I (CNA-I) cooling channels using a LECO gas analyser. Original samples were previously separated into fractions at the Laboratiorio para Ensayos de Post-Irradiacion (LAPEP), Centro Atomico Ezeiza. The practice and the preliminary conditions of the laboratory and equipment to reduce the occupational dose for personnel and the work area contamination are described in this paper. In addition to the training activity for workers, the radiological control performed during the intervention and procedure followed to decontaminate LECO and the laboratory are summarized here. (authors)

  11. Comparative Studies on the Bioretention of Radionuclides under Laboratory and Field Conditions

    International Nuclear Information System (INIS)

    Heyraud, M.; Fowler, S.W.

    1976-01-01

    The influence of different sea water treatments on radio-isotope flux rates was tested in three species. For any one species no significant differences in 65 Zn loss rate were noted between organisms held in sea water collected in situ and in those maintained in sea water from the laboratory system. Increased sea water zinc concentration accelerated 65 Zn flux rates; however, the more rapid 65 Zn loss compared to that measured in control sea water was only significant when the concentration was increased by 100μg zinc/liter. Simultaneous laboratory and field experiments indicated that loss rates in clams and mussels were similar whether animals were held in the field or in the laboratory. Experiments in which crabs were monitored for 65 Zn loss gave conflicting results. One experiment performed during the summer indicated that crabs lost 65 Zn significantly faster in the laboratory than in the field. Another experiment performed during the winter when water temperatures were lower indicated no differences in loss rates between the two systems. Differences in radioisotope flux rate may have been related to the intermolt cycle; nevertheless, it was concluded that for certain organisms care should be exercised when applying results of laboratory experiments to the field situation. (author)

  12. Emotional intelligence in medical laboratory science

    Science.gov (United States)

    Price, Travis

    The purpose of this study was to explore the role of emotional intelligence (EI) in medical laboratory science, as perceived by laboratory administrators. To collect and evaluate these perceptions, a survey was developed and distributed to over 1,400 medical laboratory administrators throughout the U.S. during January and February of 2013. In addition to demographic-based questions, the survey contained a list of 16 items, three skills traditionally considered important for successful work in the medical laboratory as well as 13 EI-related items. Laboratory administrators were asked to rate each item for its importance for job performance, their satisfaction with the item's demonstration among currently working medical laboratory scientists (MLS) and the amount of responsibility college-based medical laboratory science programs should assume for the development of each skill or attribute. Participants were also asked about EI training in their laboratories and were given the opportunity to express any thoughts or opinions about EI as it related to medical laboratory science. This study revealed that each EI item, as well as each of the three other items, was considered to be very or extremely important for successful job performance. Administrators conveyed that they were satisfied overall, but indicated room for improvement in all areas, especially those related to EI. Those surveyed emphasized that medical laboratory science programs should continue to carry the bulk of the responsibility for the development of technical skills and theoretical knowledge and expressed support for increased attention to EI concepts at the individual, laboratory, and program levels.

  13. Laboratory simulation of maintenance activity

    International Nuclear Information System (INIS)

    Kantowitz, B.H.

    1988-01-01

    Laboratory research in highly controlled settings can augment, but not replace, studies in plant or training center locations. A laboratory simulation involves abstraction of the human information processing and social interactions required in prototypical maintenance tasks. A variety of independent variables can be studied quickly, efficiently, and at relatively low cost. Sources of human error can be identified in terms of models of human perception, cognition, action, attention, and social/organizational processes. This paper discusses research in progress at the Battelle Human Performance Laboratory. Both theoretical aspects and practical implications are considered. Directions for future human factors research are indicated

  14. LABORATORY SCALE STEAM INJECTION TREATABILITY STUDIES

    Science.gov (United States)

    Laboratory scale steam injection treatability studies were first developed at The University of California-Berkeley. A comparable testing facility has been developed at USEPA's Robert S. Kerr Environmental Research Center. Experience has already shown that many volatile organic...

  15. Use of Galvanic Skin Responses, Salivary Biomarkers, and Self-reports to Assess Undergraduate Student Performance During a Laboratory Exam Activity

    Science.gov (United States)

    Villanueva, Idalis; Valladares, Maria; Goodridge, Wade

    2016-01-01

    Typically, self-reports are used in educational research to assess student response and performance to a classroom activity. Yet, addition of biological and physiological measures such as salivary biomarkers and galvanic skin responses are rarely included, limiting the wealth of information that can be obtained to better understand student performance. A laboratory protocol to study undergraduate students' responses to classroom events (e.g., exams) is presented. Participants were asked to complete a representative exam for their degree. Before and after the laboratory exam session, students completed an academic achievement emotions self-report and an interview that paralleled these questions when participants wore a galvanic skin sensor and salivary biomarkers were collected. Data collected from the three methods resulted in greater depth of information about students' performance when compared to the self-report. The work can expand educational research capabilities through more comprehensive methods for obtaining nearer to real-time student responses to an examination activity. PMID:26891278

  16. Transuranics Laboratory, achievements and performance; Laboratorio de Transuranicos, logros y fundamento

    Energy Technology Data Exchange (ETDEWEB)

    Gasco, C.; Anton, M. P.

    2004-07-01

    The Marine and Aquatic Radioecology Group (MARG) was established in 1985 with the main scope of analysing the consequences of the Palomares accident in the adjacent Mediterranean ecosystem. From then on and up to now , this Group has extended its investigations to other European marine environments, such as the Spanish Mediterranean margin, the Artic and the Atlantic. The main research of long-lived radionuclides (plutonium, americium and Cs-137) determining the orography influence, riverine inputs and their geo-chemical associations. This group is currently accomplishing new challenges on the radioecology field such as the development of techniques for transuranics speciation to determine their geo-chemical association to the main sediment compounds. Natural and anthropogenic radionuclides distribution on salt-marsh areas affected by dry-wet periods is being studied as well as the possibilities of fusing crossed techniques for dating recent sediments (pollen, anthropogenic, ''210 Pb, etc). The Laboratory performance description, the procedures used, calculations, challenges and gaps are described in this report. (Author) 22 refs.

  17. Internal quality control indicators of cervical cytopathology exams performed in laboratories monitored by the External Quality Control Laboratory.

    Science.gov (United States)

    Ázara, Cinara Zago Silveira; Manrique, Edna Joana Cláudio; Tavares, Suelene Brito do Nascimento; de Souza, Nadja Lindany Alves; Amaral, Rita Goreti

    2014-09-01

    To evaluate the impact of continued education provided by an external quality control laboratory on the indicators of internal quality control of cytopathology exams. The internal quality assurance indicators for cytopathology exams from 12 laboratories monitored by the External Quality Control Laboratory were evaluated. Overall, 185,194 exams were included, 98,133 of which referred to the period preceding implementation of a continued education program, while 87,061 referred to the period following this intervention. Data were obtained from the Cervical Cancer Database of the Brazilian National Health Service. Following implementation of the continued education program, the positivity index (PI) remained within recommended limits in four laboratories. In another four laboratories, the PI progressed from below the limits to within the recommended standards. In one laboratory, the PI remained low, in two laboratories, it remained very low, and in one, it increased from very low to low. The percentage of exams compatible with a high-grade squamous intraepithelial lesion (HSIL) remained within the recommended limits in five laboratories, while in three laboratories it progressed from below the recommended levels to >0.4% of the total number of satisfactory exams, and in four laboratories it remained below the standard limit. Both the percentage of atypical squamous cells of undetermined significance (ASC-US) in relation to abnormal exams, and the ratio between ASC-US and intraepithelial lesions remained within recommended levels in all the laboratories investigated. An improvement was found in the indicators represented by the positivity index and the percentage of exams compatible with a high-grade squamous intraepithelial lesion, showing that the role played by the external quality control laboratory in providing continued education contributed towards improving laboratory staff skills in detecting cervical cancer precursor lesions.

  18. Cost-price estimation of clinical laboratory services based on activity-based costing: A case study from a developing country.

    Science.gov (United States)

    Mouseli, Ali; Barouni, Mohsen; Amiresmaili, Mohammadreza; Samiee, Siamak Mirab; Vali, Leila

    2017-04-01

    It is believed that laboratory tariffs in Iran don't reflect the real costs. This might expose private laboratories at financial hardship. Activity Based Costing is widely used as a cost measurement instrument to more closely approximate the true cost of operations. This study aimed to determine the real price of different clinical tests of a selected private clinical laboratory. This study was a cross sectional study carried out in 2015. The study setting was the private laboratories in the city of Kerman, Iran. Of 629 tests in the tariff book of the laboratory (relative value), 188 tests were conducted in the laboratory that used Activity Based Costing (ABC) methodology to estimate cost-price. Analyzing and cost-price estimating of laboratory services were performed by MY ABCM software Version 5.0. In 2015, the total costs were $641,645. Direct and indirect costs were 78.3% and 21.7% respectively. Laboratory consumable costs by 37% and personnel costs by 36.3% had the largest share of the costing. Also, group of hormone tests cost the most $147,741 (23.03%), and other tests group cost the least $3,611 (0.56%). Also after calculating the cost of laboratory services, a comparison was made between the calculated price and the private sector's tariffs in 2015. This study showed that there was a difference between costs and tariffs in the private laboratory. One way to overcome this problem is to increase the number of laboratory tests with regard to capacity of the laboratories.

  19. Simulation of the hydraulic performance of highway filter drains through laboratory models and stormwater management tools.

    Science.gov (United States)

    Sañudo-Fontaneda, Luis A; Jato-Espino, Daniel; Lashford, Craig; Coupe, Stephen J

    2017-05-23

    Road drainage is one of the most relevant assets in transport infrastructure due to its inherent influence on traffic management and road safety. Highway filter drains (HFDs), also known as "French Drains", are the main drainage system currently in use in the UK, throughout 7000 km of its strategic road network. Despite being a widespread technique across the whole country, little research has been completed on their design considerations and their subsequent impact on their hydraulic performance, representing a gap in the field. Laboratory experiments have been proven to be a reliable indicator for the simulation of the hydraulic performance of stormwater best management practices (BMPs). In addition to this, stormwater management tools (SMT) have been preferentially chosen as a design tool for BMPs by practitioners from all over the world. In this context, this research aims to investigate the hydraulic performance of HFDs by comparing the results from laboratory simulation and two widely used SMT such as the US EPA's stormwater management model (SWMM) and MicroDrainage®. Statistical analyses were applied to a series of rainfall scenarios simulated, showing a high level of accuracy between the results obtained in laboratory and using SMT as indicated by the high and low values of the Nash-Sutcliffe and R 2 coefficients and root-mean-square error (RMSE) reached, which validated the usefulness of SMT to determine the hydraulic performance of HFDs.

  20. Los Alamos National Laboratory plans for a laboratory microfusion facility

    International Nuclear Information System (INIS)

    Harris, D.B.

    1988-01-01

    Los Alamos National Laboratory is actively participating in the National Laboratory Microfusion Facility (LMF) Scoping Study. We are currently performing a conceptual design study of a krypton-fluoride laser system that appears to meet all of the diver requirements for the LMF. A new theory of amplifier module scaling has been developed recently and it appears that KrF amplifier modules can be scaled up to output energies much larger than thought possible a few years ago. By using these large amplifier modules, the reliability and availability of the system is increased and its cost and complexity is decreased. Final cost figures will be available as soon as the detailed conceptual design is complete

  1. Performance and evaluation for a single crystal gamma spectrometer in environmental laboratory

    International Nuclear Information System (INIS)

    Pan Jingquan

    1991-01-01

    The performance of a Ge(Li) spectrometer system for measuring low-level environmental γ0ray samples is presented. It has a resolution of 2 keV, and an efficiency of 30% relative to 3 by 3 inch NaI (Tl) for the 1332 keV γ-ray of 60 Co. The integral background counts of γ-ray photons is 140 ± 2 cpm in the energy range from 12 to 2000 keV. Based on applications of measuring different types of samples, it is proved that the performance of the Ge(Li) γ-spectrometer system with a 10 cm thickness lead shield, coordinating a good experimental method, will be enough for environmental sample analyses in environmental laboratory

  2. Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory

    International Nuclear Information System (INIS)

    Advanced Light Source; Yashchuk, Valeriy V; Kirschman, Jonathan L.; Domning, Edward E.; McKinney, Wayne R.; Morrison, Gregory Y.; Smith, Brian V.; Yashchuk, Valeriy V.

    2008-01-01

    The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the stage, and analysis of the performance by a slope measurement of a highly curved super-quality substrate with less than 0.3 microradian (rms)slope variation

  3. Medical laboratory scientist

    DEFF Research Database (Denmark)

    Smith, Julie; Qvist, Camilla Christine; Jacobsen, Katja Kemp

    2017-01-01

    Previously, biomarker research and development was performed by laboratory technicians working as craftsmen in laboratories under the guidance of medical doctors. This hierarchical structure based on professional boundaries appears to be outdated if we want to keep up with the high performance...... of our healthcare system, and take advantage of the vast potential of future biomarkers and personalized medicine. We ask the question; does our healthcare system benefit from giving the modern medical laboratory scientist (MLS) a stronger academic training in biomarker research, development...

  4. Cold Climate Foundation Retrofit Experimental Hygrothermal Performance: Cloquet Residential Research Facility Laboratory Results

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, Louise F. [NorthernSTAR, St. Paul, MN (United States); Harmon, Anna C. [NorthernSTAR, St. Paul, MN (United States)

    2015-04-01

    Thermal and moisture problems in existing basements create a unique challenge because the exterior face of the wall is not easily or inexpensively accessible. This approach addresses thermal and moisture management from the interior face of the wall without disturbing the exterior soil and landscaping. the interior and exterior environments. This approach has the potential for improving durability, comfort, and indoor air quality. This project was funded jointly by the National Renewable Energy Laboratory (NREL) and Oak Ridge National Laboratory (ORNL). ORNL focused on developing a full basement wall system experimental database to enable others to validate hygrothermal simulation codes. NREL focused on testing the moisture durability of practical basement wall interior insulation retrofit solutions for cold climates. The project has produced a physically credible and reliable long-term hygrothermal performance database for retrofit foundation wall insulation systems in zone 6 and 7 climates that are fully compliant with the performance criteria in the 2009 Minnesota Energy Code. The experimental data were configured into a standard format that can be published online and that is compatible with standard commercially available spreadsheet and database software.

  5. Strengthening LLNL Missions through Laboratory Directed Research and Development in High Performance Computing

    Energy Technology Data Exchange (ETDEWEB)

    Willis, D. K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-12-01

    High performance computing (HPC) has been a defining strength of Lawrence Livermore National Laboratory (LLNL) since its founding. Livermore scientists have designed and used some of the world’s most powerful computers to drive breakthroughs in nearly every mission area. Today, the Laboratory is recognized as a world leader in the application of HPC to complex science, technology, and engineering challenges. Most importantly, HPC has been integral to the National Nuclear Security Administration’s (NNSA’s) Stockpile Stewardship Program—designed to ensure the safety, security, and reliability of our nuclear deterrent without nuclear testing. A critical factor behind Lawrence Livermore’s preeminence in HPC is the ongoing investments made by the Laboratory Directed Research and Development (LDRD) Program in cutting-edge concepts to enable efficient utilization of these powerful machines. Congress established the LDRD Program in 1991 to maintain the technical vitality of the Department of Energy (DOE) national laboratories. Since then, LDRD has been, and continues to be, an essential tool for exploring anticipated needs that lie beyond the planning horizon of our programs and for attracting the next generation of talented visionaries. Through LDRD, Livermore researchers can examine future challenges, propose and explore innovative solutions, and deliver creative approaches to support our missions. The present scientific and technical strengths of the Laboratory are, in large part, a product of past LDRD investments in HPC. Here, we provide seven examples of LDRD projects from the past decade that have played a critical role in building LLNL’s HPC, computer science, mathematics, and data science research capabilities, and describe how they have impacted LLNL’s mission.

  6. Do Targeted Written Comments and the Rubric Method of Delivery Affect Performance on Future Human Physiology Laboratory Reports?

    Science.gov (United States)

    Clayton, Zachary S.; Wilds, Gabriel P.; Mangum, Joshua E.; Hocker, Austin D.; Dawson, Sierra M.

    2016-01-01

    We investigated how students performed on weekly two-page laboratory reports based on whether the grading rubric was provided to the student electronically or in paper form and the inclusion of one- to two-sentence targeted comments. Subjects were registered for a 289-student, third-year human physiology class with laboratory and were randomized…

  7. Buried Transuranic Waste Studies Program at the Idaho National Engineering Laboratory: Annual technology assessment and progress report

    International Nuclear Information System (INIS)

    Low, J.O.; Allman, D.W.; Shaw, P.G.; Sill, C.W.

    1987-01-01

    In-situ grouting, an improved-confinement technology that could be applied to the Idaho National Engineering Laboratory (INEL) shallow-land-buried transuranic (TRU) waste, is being investigated by EG and G Idaho, Inc. In situ grouting has been demonstrated as the culmination of a two-year engineering feasibility test at the INEL. In situ stabilization and hydrologic isolation of a simulated buried TRU waste trench at an arid site were performed using an experimental dynamic compaction in situ grouting process developed by Rockwell Hanford Operations (RHO). A series of laboratory evaluations relative to the grout permeation characteristics of microfine particulate cements with INEL-type soil was performed prior to the grouting operations. In addition, an extensive pre-grouting hydrologic assessment of the test trench was performed to support the performance assessment analysis. Laboratory testing of various chemical materials yielded a suitable hydrologic tracer for use in the hydrologic monitoring phase of the experiment. Various plutonium transport laboratory evaluations were performed to assess the plutonium retention capabilities of a microfine grout/INEL-soil waste product similar to that expected to result if the grout is injected in situ into the INEL test trench. The test trench will be hydrologically assessed in FY 1987 to determine if the RHO grouting system attained the performance acceptance criteria of the experiment. The report includes a technology assessment of buried waste technologies developed by other DOE sites. Field demonstrations at ORNL and Hanford are reported under this technology assessment. Also included is information on activities related to buried waste management at the INEL. These include environmental surveillance of the Radioactive Waste Management Complex and the Subsurface Migration Studies Program

  8. Improvement of darts performance following lucid dream practice depends on the number of distractions while rehearsing within the dream - a sleep laboratory pilot study.

    Science.gov (United States)

    Schädlich, Melanie; Erlacher, Daniel; Schredl, Michael

    2017-12-01

    In a lucid dream, the dreamer is aware of the dream state and can deliberately practice motor skills. Two field studies indicated that lucid dream practice can improve waking performance in simple motor tasks. The present pilot study investigated the effect of lucid dream practice in a controlled sleep laboratory setting, using a pre-post design with dart throwing in the evening and morning. The experimental group practiced darts in lucid dreams. Because some participants were distracted during lucid dream practice, the group was divided into lucid dreamers with few (n = 4) and many distractions (n = 5). Change of performance was compared to a physical practice group (n = 9) and a control group (n = 9), showing a significant interaction (P = .013, η 2  = .368). Only the lucid dreamers with few distractions improved (18%) significantly over time (P = .005, d = 3.84). Even though these results have to be considered preliminary, the present study indicates that lucid dream practice can be an effective tool in sports practice if lucid dreamers find ways to minimise distractions during lucid dream practice. Moreover, the study emphasises the necessity to investigate lucid dream practice experiences on a qualitative level.

  9. Photovoltaic Characterization Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — NIST's PV characterization laboratory is used to measure the electrical performance and opto-electronic properties of solar cells and modules. This facility consists...

  10. Laboratory Building

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, Joshua M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    This report is an analysis of the means of egress and life safety requirements for the laboratory building. The building is located at Sandia National Laboratories (SNL) in Albuquerque, NM. The report includes a prescriptive-based analysis as well as a performance-based analysis. Following the analysis are appendices which contain maps of the laboratory building used throughout the analysis. The top of all the maps is assumed to be north.

  11. Performance of laboratories in speciation analysis in seafood – Case of methylmercury and inorganic arsenic

    DEFF Research Database (Denmark)

    Baer, Ines; Baxter, Malcolm; Devesa, Vicenta

    2011-01-01

    arsenic analysis. Results for inorganic arsenic were spread, but not method dependant. The measurand seems to be difficult to analyse in this matrix and possible method issues were identified. Methylmercury results were satisfactory, but not many laboratories perform this type of analysis because...

  12. Isotretinoin therapy: Any need for laboratory assessment? | Tallab ...

    African Journals Online (AJOL)

    Background: Recently studies showed the no need for laboratory follow up of patients on isotretinoin therapy. The aim of this study is to assess this issue. Patients and methods: A retrospective study on 400 patients was performed to analyze the laboratory data before and after isotretinoin therapy of acne vulgaris patients.

  13. Laboratory Oxidation Stability Study on B10 Biodiesel Blends

    Energy Technology Data Exchange (ETDEWEB)

    Engelen, B. [and others

    2013-11-15

    A laboratory oxidation stability study has been completed jointly by CONCAWE and DGMK on three biodiesel blends containing 10% v/v (B10) Fatty Acid Methyl Ester (FAME). The results of the study are compared to measurements from an in-vehicle storage stability study on similar B10 diesel fuels that had been conducted previously in a Joint Industry Study. This laboratory study monitored the oxidation stability of the three B10 blends during six weeks of laboratory storage under ambient (25C) and elevated temperature (43C) conditions. Various test methods were used to monitor oxidation stability changes in the B10 diesel fuel blends including electrical conductivity, viscosity, Rancimat oxidation stability (EN 15751), PetroOxy oxidation stability (EN 16091), acid number (EN 14104), Delta Total Acid Number (Delta TAN), and peroxide number (ISO 3960). Elemental analyses by ICP were also completed on the FAME and B10 blends at the start and end of the laboratory study. The concentrations of dissolved metals were very low in all cases except for silicon which was found to be between about 600-700 ppb in the B10 blends. A limited study was also conducted on one neat FAME sample (B100) to investigate the effect of air/oxygen exposure on the rate of decrease in oxidation stability.

  14. US QCD computational performance studies with PERI

    International Nuclear Information System (INIS)

    Zhang, Y; Fowler, R; Huck, K; Malony, A; Porterfield, A; Reed, D; Shende, S; Taylor, V; Wu, X

    2007-01-01

    We report on some of the interactions between two SciDAC projects: The National Computational Infrastructure for Lattice Gauge Theory (USQCD), and the Performance Engineering Research Institute (PERI). Many modern scientific programs consistently report the need for faster computational resources to maintain global competitiveness. However, as the size and complexity of emerging high end computing (HEC) systems continue to rise, achieving good performance on such systems is becoming ever more challenging. In order to take full advantage of the resources, it is crucial to understand the characteristics of relevant scientific applications and the systems these applications are running on. Using tools developed under PERI and by other performance measurement researchers, we studied the performance of two applications, MILC and Chroma, on several high performance computing systems at DOE laboratories. In the case of Chroma, we discuss how the use of C++ and modern software engineering and programming methods are driving the evolution of performance tools

  15. Terrain And Laboratory Conductivity Studies Of Flood Plains Of ...

    African Journals Online (AJOL)

    A shallow electromagnetic study (electrical conductivity and magnetic susceptibility measurements) and laboratory conductivity sampling of the flood plains of Oluwatuyi/Oshinle area of Akure have been undertaken. This is with the aim of correlating the terrain conductivity mapping with laboratory measurements to establish ...

  16. Photovoltaic Device Performance Evaluation Using an Open-Hardware System and Standard Calibrated Laboratory Instruments

    Directory of Open Access Journals (Sweden)

    Jesús Montes-Romero

    2017-11-01

    Full Text Available This article describes a complete characterization system for photovoltaic devices designed to acquire the current-voltage curve and to process the obtained data. The proposed system can be replicated for educational or research purposes without having wide knowledge about electronic engineering. Using standard calibrated instrumentation, commonly available in any laboratory, the accuracy of measurements is ensured. A capacitive load is used to bias the device due to its versatility and simplicity. The system includes a common part and an interchangeable part that must be designed depending on the electrical characteristics of each PV device. Control software, developed in LabVIEW, controls the equipment, performs automatic campaigns of measurements, and performs additional calculations in real time. These include different procedures to extrapolate the measurements to standard test conditions and methods to obtain the intrinsic parameters of the single diode model. A deep analysis of the uncertainty of measurement is also provided. Finally, the proposed system is validated by comparing the results obtained from some commercial photovoltaic modules to the measurements given by an independently accredited laboratory.

  17. Quality improvement project in cervical cancer screening: practical measures for monitoring laboratory performance.

    Science.gov (United States)

    Tarkkanen, Jussi; Geagea, Antoine; Nieminen, Pekka; Anttila, Ahti

    2003-01-01

    We conducted a quality improvement project in a cervical cancer screening programme in Helsinki in order to see if detection of precancerous lesions could be influenced by external (participation rate) and internal (laboratory praxis) quality measures. In order to increase the participation rate, a second personal invitation to Pap-test was mailed to nonparticipants of the first call. In order to improve the quality of screening, the cytotechnicians monitored their performance longitudinally by recording the number of slides reviewed per day, the pick-up rate of abnormal smears, the report of the consulting cytopathologist, and the number of histologically verified lesions detected from the cases that they had screened. Regular sessions were held to compare the histological findings with the cytological findings of all cases referred for colposcopy. No pressure was applied on the cytotechnicians to ensure that they felt comfortable with their daily workload. A total of 110 000 smears were screened for cervical cancer at the Helsinki City Hospital during 1996-99. Initially, the overall participation rate increased from 62% to 71%. The number of histologically confirmed precancerous lesions (CIN 1-3) more than doubled and their detection rate increased from 0.32% to 0.72%. Continuous education and feedback from daily work performance were important, yet rather inexpensive means in increasing laboratory performance. Additional measures are needed to further increase the participation rate. Impact of the quality measures on cancer incidence needs to be assessed later on.

  18. Performance of laboratories analysing welding fume on filter samples: results from the WASP proficiency testing scheme.

    Science.gov (United States)

    Stacey, Peter; Butler, Owen

    2008-06-01

    This paper emphasizes the need for occupational hygiene professionals to require evidence of the quality of welding fume data from analytical laboratories. The measurement of metals in welding fume using atomic spectrometric techniques is a complex analysis often requiring specialist digestion procedures. The results from a trial programme testing the proficiency of laboratories in the Workplace Analysis Scheme for Proficiency (WASP) to measure potentially harmful metals in several different types of welding fume showed that most laboratories underestimated the mass of analyte on the filters. The average recovery was 70-80% of the target value and >20% of reported recoveries for some of the more difficult welding fume matrices were welding fume trial filter samples. Consistent rather than erratic error predominated, suggesting that the main analytical factor contributing to the differences between the target values and results was the effectiveness of the sample preparation procedures used by participating laboratories. It is concluded that, with practice and regular participation in WASP, performance can improve over time.

  19. Providing critical laboratory results on time, every time to help reduce emergency department length of stay: how our laboratory achieved a Six Sigma level of performance.

    Science.gov (United States)

    Blick, Kenneth E

    2013-08-01

    To develop a fully automated core laboratory, handling samples on a "first in, first out" real-time basis with Lean/Six Sigma management tools. Our primary goal was to provide services to critical care areas, eliminating turnaround time outlier percentage (TAT-OP) as a factor in patient length of stay (LOS). A secondary goal was to achieve a better laboratory return on investment. In 2011, we reached our primary goal when we calculated the TAT-OP distribution and found we had achieved a Six Sigma level of performance, ensuring that our laboratory service can be essentially eliminated as a factor in emergency department patient LOS. We also measured return on investment, showing a productivity improvement of 35%, keeping pace with our increased testing volume. As a result of our Lean process improvements and Six Sigma initiatives, in part through (1) strategic deployment of point-of-care testing and (2) core laboratory total automation with robotics, middleware, and expert system technology, physicians and nurses at the Oklahoma University Medical Center can more effectively deliver lifesaving health care using evidence-based protocols that depend heavily on "on time, every time" laboratory services.

  20. The effect of restructuring student writing in the general chemistry laboratory on student understanding of chemistry and on students' approach to the laboratory course

    Science.gov (United States)

    Rudd, James Andrew, II

    Many students encounter difficulties engaging with laboratory-based instruction, and reviews of research have indicated that the value of such instruction is not clearly evident. Traditional forms of writing associated with laboratory activities are commonly in a style used by professional scientists to communicate developed explanations. Students probably lack the interpretative skills of a professional, and writing in this style may not support students in learning how to develop scientific explanations. The Science Writing Heuristic (SWH) is an inquiry-based approach to laboratory instruction designed in part to promote student ability in developing such explanations. However, there is not a convincing body of evidence for the superiority of inquiry-based laboratory instruction in chemistry. In a series of studies, the performance of students using the SWH student template in place of the standard laboratory report format was compared to the performance of students using the standard format. The standard reports had Title, Purpose, Procedure, Data & Observations, Calculations & Graphs, and Discussion sections. The SWH reports had Beginning Questions & Ideas, Tests & Procedures, Observations, Claims, Evidence, and Reflection sections. The pilot study produced evidence that using the SWH improved the quality of laboratory reports, improved student performance on a laboratory exam, and improved student approach to laboratory work. A main study found that SWH students statistically exhibited a better understanding of physical equilibrium when written explanations and equations were analyzed on a lecture exam and performed descriptively better on a physical equilibrium practical exam task. In another main study, the activities covering the general equilibrium concept were restructured as an additional change, and it was found that SWH students exhibited a better understanding of chemical equilibrium as shown by statistically greater success in overcoming the common

  1. Laboratory Information Management System (LIMS): A case study

    Science.gov (United States)

    Crandall, Karen S.; Auping, Judith V.; Megargle, Robert G.

    1987-01-01

    In the late 70's, a refurbishment of the analytical laboratories serving the Materials Division at NASA Lewis Research Center was undertaken. As part of the modernization efforts, a Laboratory Information Management System (LIMS) was to be included. Preliminary studies indicated a custom-designed system as the best choice in order to satisfy all of the requirements. A scaled down version of the original design has been in operation since 1984. The LIMS, a combination of computer hardware, provides the chemical characterization laboratory with an information data base, a report generator, a user interface, and networking capabilities. This paper is an account of the processes involved in designing and implementing that LIMS.

  2. Calgary Laboratory Services

    Directory of Open Access Journals (Sweden)

    James R. Wright MD, PhD

    2015-12-01

    Full Text Available Calgary Laboratory Services provides global hospital and community laboratory services for Calgary and surrounding areas (population 1.4 million and global academic support for the University of Calgary Cumming School of Medicine. It developed rapidly after the Alberta Provincial Government implemented an austerity program to address rising health care costs and to address Alberta’s debt and deficit in 1994. Over roughly the next year, all hospital and community laboratory test funding within the province was put into a single budget, fee codes for fee-for-service test billing were closed, roughly 40% of the provincial laboratory budget was cut, and roughly 40% of the pathologists left the province of Alberta. In Calgary, in the face of these abrupt changes in the laboratory environment, private laboratories, publicly funded hospital laboratories and the medical school department precipitously and reluctantly merged in 1996. The origin of Calgary Laboratory Services was likened to an “unhappy shotgun marriage” by all parties. Although such a structure could save money by eliminating duplicated services and excess capacity and could provide excellent city-wide clinical service by increasing standardization, it was less clear whether it could provide strong academic support for a medical school. Over the past decade, iterations of the Calgary Laboratory Services model have been implemented or are being considered in other Canadian jurisdictions. This case study analyzes the evolution of Calgary Laboratory Services, provides a metric-based review of academic performance over time, and demonstrates that this model, essentially arising as an unplanned experiment, has merit within a Canadian health care context.

  3. Interlaboratory analytical performance studies; a way to estimate measurement uncertainty

    Directory of Open Access Journals (Sweden)

    El¿bieta £ysiak-Pastuszak

    2004-09-01

    Full Text Available Comparability of data collected within collaborative programmes became the key challenge of analytical chemistry in the 1990s, including monitoring of the marine environment. To obtain relevant and reliable data, the analytical process has to proceed under a well-established Quality Assurance (QA system with external analytical proficiency tests as an inherent component. A programme called Quality Assurance in Marine Monitoring in Europe (QUASIMEME was established in 1993 and evolved over the years as the major provider of QA proficiency tests for nutrients, trace metals and chlorinated organic compounds in marine environment studies. The article presents an evaluation of results obtained in QUASIMEME Laboratory Performance Studies by the monitoring laboratory of the Institute of Meteorology and Water Management (Gdynia, Poland in exercises on nutrient determination in seawater. The measurement uncertainty estimated from routine internal quality control measurements and from results of analytical performance exercises is also presented in the paper.

  4. A Three-Year Feedback Study of a Remote Laboratory Used in Control Engineering Studies

    Science.gov (United States)

    Chevalier, Amélie; Copot, Cosmin; Ionescu, Clara; De Keyser, Robin

    2017-01-01

    This paper discusses the results of a feedback study for a remote laboratory used in the education of control engineering students. The goal is to show the effectiveness of the remote laboratory on examination results. To provide an overview, the two applications of the remote laboratory are addressed: 1) the Stewart platform, and 2) the quadruple…

  5. Binary and multi-category ratings in a laboratory observer performance study: a comparison.

    Science.gov (United States)

    Gur, David; Bandos, Andriy I; King, Jill L; Klym, Amy H; Cohen, Cathy S; Hakim, Christiane M; Hardesty, Lara A; Ganott, Marie A; Perrin, Ronald L; Poller, William R; Shah, Ratan; Sumkin, Jules H; Wallace, Luisa P; Rockette, Howard E

    2008-10-01

    -reader average (0.016) was (-0.0206, 0.0631) (two-sided p-value 0.35). In conclusion the authors found that in retrospective observer performance studies the use of a binary response or a semi-continuous rating scale led to consistent results in terms of performance as measured by sensitivity-specificity operating points.

  6. [Importance of quality control of baciloscopy in laboratories that perform diagnosis of tuberculosis].

    Science.gov (United States)

    Sardiñas, Misleidis; García, Grechen; Rosarys Martínez, María; Díaz, Raúl; Mederos, Lilian M

    2016-06-01

    Baciloscopy is the primary tool for pulmonary tuberculosis diagnosis, being this technique the most used internationally in the search for infectious cases. Quality control is the process of the rechecking smears by a highly qualified observer. To evaluate and highlight the importance of quality control of smear microscopy in the Provincial Laboratories diagnosticians of Tuberculosis in Cuba. This study was conducted at the National Reference Laboratory and Research in Tuberculosis, Leprosy and Mycobacteria in the Institute of Tropical Medicine "Pedro Kouri", Havana, Cuba, Were evaluated 2676 smears received from January 2013 to December 2014, from Provincial Centers of Hygiene, Epidemiology and Microbiology of Cuba, including the special municipality Isla de la Juventud. 2,664 (99.5%) were concordant smears, the correlation obtained for the positive smears were 96.5% and 99.8% for negative. Were identified12 reading errors: 7 (3.5%) false positive and 5 (0.2%) false negatives. Slides were classified with adequate quality of smears in 2039 (76.2%), showed difficulties in realizing the extension in 1464 (54.7%) and staining were adequate in 2343 (87.6%). The kappa index was 0.9674. Although there was good agreement between observations it is recommended to improve the quality of extended, maintain staff training program that performs this activity, like regular supervision by specialists, to further improve the quality of diagnosis.

  7. Design of laboratory radiotracer studies in marine radioecology

    International Nuclear Information System (INIS)

    Schulte, E.H.

    1997-01-01

    A condensed description of methods used in laboratory radiotracer studies in marine radioecology is presented showing also the difficulties which may be encountered in order to obtain realistic and comparable information on the general behaviour of radionuclides in marine organisms. Practical guidance on the choice of the biological material and how to setup laboratory experiments and to control properly important experimental conditions are given. Key parameters like concentration factors and biological half-lives are defined and the theoretical estimation and practical determination of input, uptake, accumulation and loss of radionuclides in marine biota are formulated by the aid of mathematical equations. Examples of uptake and loss curves obtained in the laboratory are shown. The importance of some environmental factors (temperature, food, growth) on uptake and loss of radionuclides are demonstrated. Comparison of experimental and field data of concentration factors is reported to show the difficulty in extrapolating from laboratory experiments to nature. (author)

  8. Evaluation of Performance of Laboratories and Manufacturers Within the Framework of the IFCC model for Quality Targets of HbA1c.

    Science.gov (United States)

    Weykamp, Cas; Siebelder, Carla

    2017-11-01

    HbA1c is a key parameter in diabetes management. For years the test has been used exclusively for monitoring of long-term diabetic control. However, due to improvement of the performance, HbA1c is considered more and more for diagnosis and screening. With this new application, quality demands further increase. A task force of the International Federation of Clinical Chemistry and Laboratory Medicine developed a model to set and evaluate quality targets for HbA1c. The model is based on the concept of total error and takes into account the major sources of analytical errors in the medical laboratory: bias and imprecision. Performance criteria are derived from sigma-metrics and biological variation. This review shows 2 examples of the application of the model: at the level of single laboratories, and at the level of a group of laboratories. In the first example data of 125 individual laboratories of a recent external quality assessment program in the Netherlands are evaluated. Differences between laboratories as well as their relation to method principles are shown. The second example uses recent and 3-year-old data of the proficiency test of the College of American Pathologists. The differences in performance between 26 manufacturer-related groups of laboratories are shown. Over time these differences are quite consistent although some manufacturers improved substantially either by better standardization or by replacing a test. The IFCC model serves all who are involved in HbA1c testing in the ongoing process of better performance and better patient care.

  9. The performance of the remote analytical laboratory during the first fluorinel dissolution process campaign

    International Nuclear Information System (INIS)

    Lewis, L.C.; Henscheid, J.P.

    1989-01-01

    The Remote Analytical Laboratory at the Idaho Chemical Processing Plant was designed to provide analytical chemistry support to the irradiated fuel processing and associated waste processing operations. The facility was put into radioactive operation on July 7, 1986, and operated for more than a year during the first fluorinel fuel dissolution process campaign. The facility incorporated a number of innovative features and was equipped with state-of-the-art analytical instrumentation. The success of the facility is a direct function of how well the remote analytical equipment performed. The performance is discussed in this article

  10. Oak Ridge National Laboratory DOE Site Sustainability Plan (SSP) with FY 2013 Performance Data

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, Teresa A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lapsa, Melissa Voss [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2013-12-01

    Oak Ridge National Laboratory (ORNL) is both the largest science and energy laboratory of the US Department of Energy (DOE) and one of the oldest national laboratories still operating at its original site. These characteristics provide the Sustainable Campus Initiative (SCI) both a unique opportunity and a unique challenge to integrate sustainability into facilities and activities. As outlined in this report, SCI is leveraging the outcomes of ORNL’s DOE-sponsored research and development programs to maximize the efficient use of energy and natural resources across ORNL. Wherever possible, ORNL is integrating technical innovations into new and existing facilities, systems, and processes with a widespread approach to achieving Executive Order 13514. ORNL continues to pursue and deploy innovative solutions and initiatives to advance regional, national, and worldwide sustainability and continues to transform its culture and engage employees in supporting sustainability at work, at home, and in the community. Table 1 summarizes ORNL's FY 2013 performance and planned actions to attain future goals. ORNL has achieved numerous successes during FY 2013, which are described in detail throughout this document.

  11. Study of nasal swipe analysis methods at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Metcalf, R.A.

    1996-01-01

    The Health Physics Analysis Laboratory (HPAL) performs around 30,000 nasal swipe analyses for transuranic nuclides each year in support of worker health and safety at the Los Alamos National Laboratory (LANL). The analysis method used employs cotton swabs swiped inside a nostril and liquid scintillation analyses of the swabs. The technical basis of this method was developed at LANL and has been in use for over 10 years. Recently, questions regarding the usefulness of a non-homogeneous mixture in liquid scintillation analyses have created a need for re-evaluation of the method. A study of the validity of the method shows it provides reliable, stable, and useful data as an indicator of personnel contamination. The study has also provided insight into the underlying process which occurs to allow the analysis. Further review of this process has shown that similar results can be obtained with different sample matrices, using less material than the current analysis method. This reduction can save HPAL the cost of materials as well as greatly reduce the waste created. Radionuclides of concern include Am-241, Pu-239, and Pu-238

  12. Formation of chloroform in spruce forest soil - results from laboratory incubation studies

    DEFF Research Database (Denmark)

    Haselmann, K.F.; Laturnus, F.; Svensmark, B.

    2000-01-01

    The release of chloroform, 1,1,1-trichloroethane, tetrachloromethane, trichloroethene and tetrachloroethene from an organic rich spruce forest soil was studied in laboratory incubation experiments by dynamic headspace analysis, thermodesorption and gas chromatography. Performance parameters...... are presented for the dynamic headspace system. For spruce forest soil, the results showed a significant increase in chloroform concentration in the headspace under aerobic conditions over a period of seven days, whereas the concentration of the other compounds remained fairly constant. A biogenic formation...

  13. Laboratory exercises to teach clinically relevant chemistry of antibiotics.

    Science.gov (United States)

    El Sayed, Khalid A; Chelette, Candace T

    2014-03-12

    To design, implement, and evaluate student performance on clinically relevant chemical and spectral laboratory exercises on antibiotics. In the first of 2 exercises, second-year pharmacy students enrolled in an integrated laboratory sequence course studied the aqueous stability of ß-lactam antibiotics using a spectral visual approach. In a second exercise, students studied the tendency of tetracycline, rifamycins, and fluoroquinolones to form insoluble chelate complexes (turbidity) with polyvalent metals. On a survey to assess achievement of class learning objectives, students agreed the laboratory activities helped them better retain important information concerning antibiotic stability and interactions. A significant improvement was observed in performance on examination questions related to the laboratory topics for 2012 and 2013 students compared to 2011 students who did not complete the laboratory. A 1-year follow-up examination question administered in a separate course showed >75% of the students were able to identify rifamycins-food interactions compared with laboratory exercises. The use of spectral visual approaches allowed students to investigate antibiotic stability and interactions, thus reinforcing the clinical relevance of medicinal chemistry. Students' performance on questions at the 1-year follow-up suggested increased retention of the concepts learned as a result of completing the exercises.

  14. School Physics Teacher Class Management, Laboratory Practice, Student Engagement, Critical Thinking, Cooperative Learning and Use of Simulations Effects on Student Performance

    Science.gov (United States)

    Riaz, Muhammad

    2015-01-01

    The purpose of this study was to examine how simulations in physics class, class management, laboratory practice, student engagement, critical thinking, cooperative learning, and use of simulations predicted the percentage of students achieving a grade point average of B or higher and their academic performance as reported by teachers in secondary…

  15. Assessing and Analyzing the Performance of Students in College Science Laboratories.

    Science.gov (United States)

    Kyle, William C., Jr.; And Others

    1979-01-01

    The study investigated specific student behavior in introductory and advanced college laboratories in botany, chemistry, geology, physics, and zoology. Behaviors were observed, described, and classified with no effort made to induce change, detail underlying conditions, or identify correlates. (Author/RE)

  16. A comparison of two microscale laboratory reporting methods in a secondary chemistry classroom

    Science.gov (United States)

    Martinez, Lance Michael

    This study attempted to determine if there was a difference between the laboratory achievement of students who used a modified reporting method and those who used traditional laboratory reporting. The study also determined the relationships between laboratory performance scores and the independent variables score on the Group Assessment of Logical Thinking (GALT) test, chronological age in months, gender, and ethnicity for each of the treatment groups. The study was conducted using 113 high school students who were enrolled in first-year general chemistry classes at Pueblo South High School in Colorado. The research design used was the quasi-experimental Nonequivalent Control Group Design. The statistical treatment consisted of the Multiple Regression Analysis and the Analysis of Covariance. Based on the GALT, students in the two groups were generally in the concrete and transitional stages of the Piagetian cognitive levels. The findings of the study revealed that the traditional and the modified methods of laboratory reporting did not have any effect on the laboratory performance outcome of the subjects. However, the students who used the traditional method of reporting showed a higher laboratory performance score when evaluation was conducted using the New Standards rubric recommended by the state. Multiple Regression Analysis revealed that there was a significant relationship between the criterion variable student laboratory performance outcome of individuals who employed traditional laboratory reporting methods and the composite set of predictor variables. On the contrary, there was no significant relationship between the criterion variable student laboratory performance outcome of individuals who employed modified laboratory reporting methods and the composite set of predictor variables.

  17. Analytic laboratory performance of a point of care urine culture kit for diagnosis and antibiotic susceptibility testing.

    Science.gov (United States)

    Bongard, E; Frimodt-Møller, N; Gal, M; Wootton, M; Howe, R; Francis, N; Goossens, H; Butler, C C

    2015-10-01

    Currently available point-of-care (POC) diagnostic tests for managing urinary tract infections (UTIs) in general practice are limited by poor performance characteristics, and laboratory culture generally provides results only after a few days. This laboratory evaluation compared the analytic performance of the POC UK Flexicult(™) (Statens Serum Institut) (SSI) urinary kit for quantification, identification and antibiotic susceptibility testing and routine UK National Health Service (NHS) urine processing to an advanced urine culture method. Two hundred urine samples routinely submitted to the Public Health Wales Microbiology Laboratory were divided and: (1) analysed by routine NHS microbiological tests as per local laboratory standard operating procedures, (2) inoculated onto the UK Flexicult(™) SSI urinary kit and (3) spiral plated onto Colorex Orientation UTI medium (E&O Laboratories Ltd). The results were evaluated between the NHS and Flexicult(™ )methods, and discordant results were compared to the spiral plating method. The UK Flexicult(™) SSI urinary kit was compared to routine NHS culture for identification of a pure or predominant uropathogen at ≥ 10(5) cfu/mL, with a positive discordancy rate of 13.5% and a negative discordancy rate of 3%. The sensitivity and specificity were 86.7% [95% confidence interval (CI) 73.8-93.7] and 82.6% (95% CI 75.8-87.7), respectively. The UK Flexicult(™) SSI urinary kit was comparable to routine NHS urine processing in identifying microbiologically positive UTIs in this laboratory evaluation. However, the number of false-positive samples could lead to over-prescribing of antibiotics in clinical practice. The Flexicult(™) SSI kit could be useful as a POC test for UTIs in primary care but further pragmatic evaluations are necessary.

  18. Study of Polyolefines Waste Thermo-Destruction in Large Laboratory and in Industrial Installations

    Science.gov (United States)

    2014-12-15

    obtaining a product of performance characteristics close to those of commercially available diesel oil. Experimental Research of catalytic thermo-destruction...results were compared with parameters of diesel oil which properties were specified by specialized laboratory outside (Quality Control Laboratory Fuel...content of sulphur. The chromatographic analysis of gaseous and liquid products was conducted using Autosystem XL GC– Turbo Mass chromatograph

  19. Successful Sampling Strategy Advances Laboratory Studies of NMR Logging in Unconsolidated Aquifers

    Science.gov (United States)

    Behroozmand, Ahmad A.; Knight, Rosemary; Müller-Petke, Mike; Auken, Esben; Barfod, Adrian A. S.; Ferré, Ty P. A.; Vilhelmsen, Troels N.; Johnson, Carole D.; Christiansen, Anders V.

    2017-11-01

    The nuclear magnetic resonance (NMR) technique has become popular in groundwater studies because it responds directly to the presence and mobility of water in a porous medium. There is a need to conduct laboratory experiments to aid in the development of NMR hydraulic conductivity models, as is typically done in the petroleum industry. However, the challenge has been obtaining high-quality laboratory samples from unconsolidated aquifers. At a study site in Denmark, we employed sonic drilling, which minimizes the disturbance of the surrounding material, and extracted twelve 7.6 cm diameter samples for laboratory measurements. We present a detailed comparison of the acquired laboratory and logging NMR data. The agreement observed between the laboratory and logging data suggests that the methodologies proposed in this study provide good conditions for studying NMR measurements of unconsolidated near-surface aquifers. Finally, we show how laboratory sample size and condition impact the NMR measurements.

  20. The laboratories of geological studies

    International Nuclear Information System (INIS)

    1994-01-01

    This educational document comprises 4 booklets in a folder devoted to the presentation of the ANDRA's activities in geological research laboratories. The first booklet gives a presentation of the missions of the ANDRA (the French agency for the management of radioactive wastes) in the management of long life radioactive wastes. The second booklet describes the approach of waste disposal facilities implantation. The third booklet gives a brief presentation of the scientific program concerning the underground geologic laboratories. The last booklet is a compilation of questions and answers about long-life radioactive wastes, the research and works carried out in geologic laboratories, the public information and the local socio-economic impact, and the storage of radioactive wastes in deep geological formations. (J.S.)

  1. Idaho National Laboratory Quarterly Performance Analysis for the 2nd Quarter FY 2015

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Lisbeth A. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-04-01

    This report is published quarterly by the Idaho National Laboratory (INL) Quality and Performance Management Organization. The Department of Energy (DOE) Occurrence Reporting and Processing System (ORPS), as prescribed in DOE Order 232.2, “Occurrence Reporting and Processing of Operations Information,” requires a quarterly analysis of events, both reportable and not reportable, for the previous 12 months. This report is the analysis of events for the 2nd Qtr FY-15.

  2. Reliability on intra-laboratory and inter-laboratory data of hair mineral analysis comparing with blood analysis.

    Science.gov (United States)

    Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol

    2013-02-01

    Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.

  3. Laboratory Computerization: The Case for a Prospective Analysis

    OpenAIRE

    Hurdle, John F.; Schwamm, Harry A.

    1982-01-01

    The argument is made that computerization of a laboratory should be preceeded by a thorough prospective analysis of laboratory operations. Points to be pondered include complementation of retrospective data, system cost justification, system performance justification, post-installation personnel adjustments, improved system utilization, improved manual performance, and insight into “how much” system to buy. A brief, general outline is offered describing how to approach such a study.

  4. Deep shaft high rate aerobic digestion: laboratory and pilot plant performance

    Energy Technology Data Exchange (ETDEWEB)

    Tran, F; Gannon, D

    1981-01-01

    The Deep Shaft is essentially an air-lift reactor, sunk deep in the ground (100-160 m); the resulting high hydrostatic pressure together with very efficient mixing in the shaft provide extremely high O transfer efficiencies (O.T.E.) of less than or equal to 90% vs. 4-20% in other aerators. This high O.T.E. suggests real potential for Deep-Shaft technology in the aerobic digestion of sludges and animal wastes: with conventional aerobic digesters an O.T.E. over 8% is extremely difficult to achieve. Laboratory and pilot plant Deep-Shaft aerobic digester studies carried out at Eco-Research's Pointe Claire, Quebec laboratories, and at the Paris, Ontario pilot Deep-Shaft digester are described.

  5. Pressure Swing Adsorption in the Unit Operations Laboratory

    Science.gov (United States)

    Ganley, Jason

    2018-01-01

    This paper describes a student laboratory in the Unit Operations Laboratory at the Colorado School of Mines: air separation by pressure swing adsorption. The flexibility of the system enables students to study the production of enriched nitrogen or oxygen streams. Automatic data acquisition permits the study of cycle steps and performance.…

  6. A method to evaluate performance reliability of individual subjects in laboratory research applied to work settings.

    Science.gov (United States)

    1978-10-01

    This report presents a method that may be used to evaluate the reliability of performance of individual subjects, particularly in applied laboratory research. The method is based on analysis of variance of a tasks-by-subjects data matrix, with all sc...

  7. Evaluation of Mycology Laboratory Proficiency Testing

    Science.gov (United States)

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient testing. This study addresses this issue by evaluating medical mycology OPT and comparing its fungal specimen identification error rates to those obtained in a covert (blinded) proficiency testing (CPT) program. Identifications from 188 laboratories participating in the New York State mycology OPT from 1982 to 1994 were compared with the identifications of the same fungi recovered from patient specimens in 1989 and 1994 as part of the routine procedures of 88 of these laboratories. The consistency in the identification of OPT specimens was sufficient to make accurate predictions of OPT error rates. However, while the error rates in OPT and CPT were similar for Candida albicans, significantly higher error rates were found in CPT for Candida tropicalis, Candida glabrata, and other common pathogenic fungi. These differences may, in part, be due to OPT’s use of ideal organism representatives cultured under optimum growth conditions. This difference, as well as the organism-dependent error rate differences, reflects the limitations of OPT as a means of assessing the quality of routine laboratory performance in medical mycology. PMID:10364601

  8. Methodological and reporting quality in laboratory studies of human eating behavior

    NARCIS (Netherlands)

    Robinson, E.; Bevelander, K.E.; Field, M.; Jones, A.

    2018-01-01

    The methodological quality and reporting practices of laboratory studies of human eating behavior determine the validity and replicability of nutrition science. The aim of this research was to examine basic methodology and reporting practices in recent representative laboratory studies of human

  9. IAEA intercomparison exercises of thyroid measurement: performance of Latin American and Caribbean laboratories

    International Nuclear Information System (INIS)

    Dantas, B.M.; Dantas, A.L.A.; Cruz-Suarez, R.

    2016-01-01

    131 I is widely used in Latin America and Caribbean Region in the field of nuclear medicine and has been recognised as one of the main sources of potential intake of radionuclides by the staff. The In Vivo Monitoring laboratory of the Institute for Radiation Protection and Dosimetry (IRD-CNEN-Brazil) organised three intercomparison exercises (2005, 2009 and 2013) in the scope of IAEA technical cooperation projects RLA9049 and RLA9066 aimed to disseminate and harmonise the technique for measuring 131 I in the human thyroid. The number of participants in Latin America increased from 9 to 20 institutions from 7 and 13 countries, respectively, over the last 10 y. The participants have improved significantly their ability on the in vivo measurement technique. In the 2013 round all laboratories which reported results presented performances in an acceptable range according to the ISO criteria indicating the benefit of such exercises in the region. (authors)

  10. Sleep disturbance effects of traffic noise—A laboratory study on after effects

    Science.gov (United States)

    Öhrström, E.; Rylander, R.

    1982-09-01

    Body movements during sleep and subjective sleep quality, as well as mood and performance were investigated after exposure to intermittent and continuous traffic noise during the night. In a first experiment, six young subjects slept in the laboratory for five nights; in a second experiment 12 subjects slept six consecutive nights in the laboratory. A good dose-response relationship was obtained between intermittent noise and subjective sleep quality: i.e., the higher the noise level, the poorer the sleep quality. A similar dose-response relationship was found for body movements immediately following noise peaks during nights with intermittent noise. Performance and mood tended to be worse after intermittent noise. However, these effects did not increase with an increase in noise levels. Compared with intermittent noise, continuous noise had a significantly smaller effect on sleep quality. Mood and performance were not worse after continuous noise. The results suggest that increased attention should be paid to peak noise levels when standards for nocturnal noise are set.

  11. Research Combustion Laboratory (RCL)

    Data.gov (United States)

    Federal Laboratory Consortium — The Research Combustion Laboratory (RCL) develops aerospace propulsion technology by performing tests on propulsion components and materials. Altitudes up to 137,000...

  12. State-of-the art comparability of corrected emission spectra. 2. Field laboratory assessment of calibration performance using spectral fluorescence standards.

    Science.gov (United States)

    Resch-Genger, Ute; Bremser, Wolfram; Pfeifer, Dietmar; Spieles, Monika; Hoffmann, Angelika; DeRose, Paul C; Zwinkels, Joanne C; Gauthier, François; Ebert, Bernd; Taubert, R Dieter; Voigt, Jan; Hollandt, Jörg; Macdonald, Rainer

    2012-05-01

    In the second part of this two-part series on the state-of-the-art comparability of corrected emission spectra, we have extended this assessment to the broader community of fluorescence spectroscopists by involving 12 field laboratories that were randomly selected on the basis of their fluorescence measuring equipment. These laboratories performed a reference material (RM)-based fluorometer calibration with commercially available spectral fluorescence standards following a standard operating procedure that involved routine measurement conditions and the data evaluation software LINKCORR developed and provided by the Federal Institute for Materials Research and Testing (BAM). This instrument-specific emission correction curve was subsequently used for the determination of the corrected emission spectra of three test dyes, X, QS, and Y, revealing an average accuracy of 6.8% for the corrected emission spectra. This compares well with the relative standard uncertainties of 4.2% for physical standard-based spectral corrections demonstrated in the first part of this study (previous paper in this issue) involving an international group of four expert laboratories. The excellent comparability of the measurements of the field laboratories also demonstrates the effectiveness of RM-based correction procedures.

  13. Tracking the train of thought from the laboratory into everyday life: an experience-sampling study of mind wandering across controlled and ecological contexts.

    Science.gov (United States)

    McVay, Jennifer C; Kane, Michael J; Kwapil, Thomas R

    2009-10-01

    In an experience-sampling study that bridged laboratory, ecological, and individual-differences approaches to mind-wandering research, 72 subjects completed an executive-control task with periodic thought probes (reported by McVay & Kane, 2009) and then carried PDAs for a week that signaled them eight times daily to report immediately whether their thoughts were off task. Subjects who reported more mind wandering during the laboratory task endorsed more mind-wandering experiences during everyday life (and were more likely to report worries as off-task thought content). We also conceptually replicated laboratory findings that mind wandering predicts task performance: Subjects rated their daily-life performance to be impaired when they reported off-task thoughts, with greatest impairment when subjects' mind wandering lacked metaconsciousness. The propensity to mind wander appears to be a stable cognitive characteristic and seems to predict performance difficulties in daily life, just as it does in the laboratory.

  14. Idaho National Laboratory Quarterly Performance Analysis - 1st Quarter FY2015

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Lisbeth A. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-03-01

    This report is published quarterly by the Idaho National Laboratory (INL) Quality and Performance Management Organization. The Department of Energy (DOE) Occurrence Reporting and Processing System (ORPS), as prescribed in DOE Order 232.2, “Occurrence Reporting and Processing of Operations Information,” requires a quarterly analysis of events, both reportable and not reportable, for the previous 12 months. This report is the analysis of 73 reportable events (27 from the 1St Qtr FY-15 and 46 from the prior three reporting quarters), as well as 38 other issue reports (including nine not reportable events and Significant Category A and B conditions reported during the1st Qtr FY-15) identified at INL during the past 12 months.

  15. Benchmarking and the laboratory

    Science.gov (United States)

    Galloway, M; Nadin, L

    2001-01-01

    This article describes how benchmarking can be used to assess laboratory performance. Two benchmarking schemes are reviewed, the Clinical Benchmarking Company's Pathology Report and the College of American Pathologists' Q-Probes scheme. The Clinical Benchmarking Company's Pathology Report is undertaken by staff based in the clinical management unit, Keele University with appropriate input from the professional organisations within pathology. Five annual reports have now been completed. Each report is a detailed analysis of 10 areas of laboratory performance. In this review, particular attention is focused on the areas of quality, productivity, variation in clinical practice, skill mix, and working hours. The Q-Probes scheme is part of the College of American Pathologists programme in studies of quality assurance. The Q-Probes scheme and its applicability to pathology in the UK is illustrated by reviewing two recent Q-Probe studies: routine outpatient test turnaround time and outpatient test order accuracy. The Q-Probes scheme is somewhat limited by the small number of UK laboratories that have participated. In conclusion, as a result of the government's policy in the UK, benchmarking is here to stay. Benchmarking schemes described in this article are one way in which pathologists can demonstrate that they are providing a cost effective and high quality service. Key Words: benchmarking • pathology PMID:11477112

  16. Establishment of Next-Generation Neurosurgery Research and Training Laboratory with Integrated Human Performance Monitoring.

    Science.gov (United States)

    Bernardo, Antonio

    2017-10-01

    Quality of neurosurgical care and patient outcomes are inextricably linked to surgical and technical proficiency and a thorough working knowledge of microsurgical anatomy. Neurosurgical laboratory-based cadaveric training is essential for the development and refinement of technical skills before their use on a living patient. Recent biotechnological advances including 3-dimensional (3D) microscopy and endoscopy, 3D printing, virtual reality, surgical simulation, surgical robotics, and advanced neuroimaging have proved to reduce the learning curve, improve conceptual understanding of complex anatomy, and enhance visuospatial skills in neurosurgical training. Until recently, few means have allowed surgeons to obtain integrated surgical and technological training in an operating room setting. We report on a new model, currently in use at our institution, for technologically integrated surgical training and innovation using a next-generation microneurosurgery skull base laboratory designed to recreate the setting of a working operating room. Each workstation is equipped with a 3D surgical microscope, 3D endoscope, surgical drills, operating table with a Mayfield head holder, and a complete set of microsurgical tools. The laboratory also houses a neuronavigation system, a surgical robotic, a surgical planning system, 3D visualization, virtual reality, and computerized simulation for training of surgical procedures and visuospatial skills. In addition, the laboratory is equipped with neurophysiological monitoring equipment in order to conduct research into human factors in surgery and the respective roles of workload and fatigue on surgeons' performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. An inter-laboratory comparison study on transfer, persistence and recovery of DNA from cable ties.

    Science.gov (United States)

    Steensma, Kristy; Ansell, Ricky; Clarisse, Lindy; Connolly, Edward; Kloosterman, Ate D; McKenna, Louise G; van Oorschot, Roland A H; Szkuta, Bianca; Kokshoorn, Bas

    2017-11-01

    To address questions on the activity that led to the deposition of biological traces in a particular case, general information on the probabilities of transfer, persistence and recovery of cellular material in relevant scenarios is necessary. These figures may be derived from experimental data described in forensic literature when conditions relevant to the case were included. The experimental methodology regarding sampling, DNA extraction, DNA typing and profile interpretation that were used to generate these published data may differ from those applied in the case and thus the applicability of the literature data may be questioned. To assess the level of variability that different laboratories obtain when similar exhibits are analysed, we performed an inter-laboratory study between four partner laboratories. Five sets of 20 cable ties bound by different volunteers were distributed to the participating laboratories and sampled and processed according to the in-house protocols. Differences were found for the amount of retrieved DNA, as well as for the reportability and composition of the DNA profiles. These differences also resulted in different probabilities of transfer, persistence and recovery for each laboratory. Nevertheless, when applied to a case example, these differences resulted in similar assignments of weight of evidence given activity-level propositions. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. The Vienna consensus: report of an expert meeting on the development of ART laboratory performance indicators.

    Science.gov (United States)

    2017-11-01

    This proceedings report presents the outcomes from an international workshop supported by the European Society of Human Reproduction and Embryology (ESHRE) and Alpha Scientists in Reproductive Medicine, designed to establish consensus on definitions and recommended values for Indicators for the assisted reproductive technology (ART) laboratory. Minimum performance-level values ('competency') and aspirational ('benchmark') values were recommended for a total of 19 Indicators, including 12 Key Performance Indicators (KPIs), five Performance Indicators (PIs), and two Reference Indicators (RIs). Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  19. 9 CFR 130.17 - User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for other veterinary... FEES USER FEES § 130.17 User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or at authorized sites. (a) User fees for veterinary diagnostics tests performed at the...

  20. Leadership development study :success profile competencies and high-performing leaders at Sandia National Laboratories.

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Katherine M.; Mulligan, Deborah Rae; Szenasi, Gail L.; Crowder, Stephen Vernon

    2005-04-01

    Sandia is undergoing tremendous change. Sandia's executive management recognized the need for leadership development. About ten years ago the Business, Leadership, and Management Development department in partnership with executive management developed and implemented the organizational leadership Success Profile Competencies to help address some of the changes on the horizon such as workforce losses and lack of a skill set in the area of interpersonal skills. This study addresses the need for the Business, Leadership, and Management Development department to provide statistically sound data in two areas. One is to demonstrate that the organizational 360-degree success profile assessment tool has made a difference for leaders. A second area is to demonstrate the presence of high performing leaders at the Labs. The study utilized two tools to address these two areas. Study participants were made up of individuals who have solid data on Sandia's 360-degree success profile assessment tool. The second assessment tool was comprised of those leaders who participated in the Lockheed Martin Corporation Employee Preferences Survey. Statistical data supports the connection between leader indicators and the 360-degree assessment tool. The study also indicates the presence of high performing leaders at Sandia.

  1. Plasma creatinine in dogs: intra- and inter-laboratory variation in 10 European veterinary laboratories

    Directory of Open Access Journals (Sweden)

    Ulleberg Thomas

    2011-04-01

    Full Text Available Abstract Background There is substantial variation in reported reference intervals for canine plasma creatinine among veterinary laboratories, thereby influencing the clinical assessment of analytical results. The aims of the study was to determine the inter- and intra-laboratory variation in plasma creatinine among 10 veterinary laboratories, and to compare results from each laboratory with the upper limit of its reference interval. Methods Samples were collected from 10 healthy dogs, 10 dogs with expected intermediate plasma creatinine concentrations, and 10 dogs with azotemia. Overlap was observed for the first two groups. The 30 samples were divided into 3 batches and shipped in random order by postal delivery for plasma creatinine determination. Statistical testing was performed in accordance with ISO standard methodology. Results Inter- and intra-laboratory variation was clinically acceptable as plasma creatinine values for most samples were usually of the same magnitude. A few extreme outliers caused three laboratories to fail statistical testing for consistency. Laboratory sample means above or below the overall sample mean, did not unequivocally reflect high or low reference intervals in that laboratory. Conclusions In spite of close analytical results, further standardization among laboratories is warranted. The discrepant reference intervals seem to largely reflect different populations used in establishing the reference intervals, rather than analytical variation due to different laboratory methods.

  2. Laboratory Approaches to Studying Occupants

    DEFF Research Database (Denmark)

    Wagner, Andreas; Andersen, Rune; Zhang, Hui

    2018-01-01

    is high and a large number of physical, physiological, and psychological quantities can be monitored. This chapter gives an overview of various types of test facilities in the world and their main features in terms of experimental opportunities. It then presents typical technical equipment and sensor......Laboratories offer the possibility to study occupant behavior in a very detailed manner. A wide range of indoor environmental scenarios can be simulated under precisely controlled conditions, and human subjects can be selected based on pre-defined criteria. The degree of control over experiments...

  3. 2003 Wastewater Land Application Site Performance Reports for the Idaho National Engineering and Environmental Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Teresa R. Meachum

    2004-02-01

    The 2003 Wastewater Land Application Site Performance Reports for the Idaho National Engineering and Environmental Laboratory describe the conditions for the facilities with State of Idaho Wastewater Land Application Permits. Permit-required monitoring data are summarized, and permit exceedences or environmental impacts relating to the operations of the facilities during the 2003 permit year are discussed.

  4. Does external evaluation of laboratories improve patient safety?

    Science.gov (United States)

    Noble, Michael A

    2007-01-01

    Laboratory accreditation and External Quality Assessment (also called proficiency testing) are mainstays of laboratory quality assessment and performance. Both practices are associated with examples of improved laboratory performance. The relationship between laboratory performance and improved patient safety is more difficult to assess because of the many variables that are involved with patient outcome. Despite this difficulty, the argument to continue external evaluation of laboratories is too compelling to consider the alternative.

  5. High Performance Liquid Chromatography Experiments to Undergraduate Laboratories

    Science.gov (United States)

    Kissinger, Peter T.; And Others

    1977-01-01

    Reviews the principles of liquid chromatography with electrochemical detection (LCEC), an analytical technique that incorporates the advantages of both liquids chromatography and electrochemistry. Also suggests laboratory experiments using this technique. (MLH)

  6. Army agrees to new study of biowarfare laboratory.

    Science.gov (United States)

    Smith, R Jeffrey

    1985-02-08

    As a result of a lawsuit initiated by Washington activist Jeremy Rifkin and joined by the attorney general for the state of Utah, the U.S. Army has agreed to defer construction, pending a study of potential environmental hazards, of a new laboratory that was authorized by a small number of Congressmen under an unusual procedure in December 1984. The laboratory, intended for tests of highly infectious and lethal biological aerosols, has aroused controversy because of fears that the data gathered there might be used to develop offensive biological weapons.

  7. Detroit District Laboratory (DET)

    Data.gov (United States)

    Federal Laboratory Consortium — Program CapabilitiesDET-DO Laboratory is equipped with the usual instrumentation necessary to perform a wide range of analyses of food, drugs and cosmetics. Program...

  8. Laboratory Demographics Lookup Tool

    Data.gov (United States)

    U.S. Department of Health & Human Services — This website provides demographic information about laboratories, including CLIA number, facility name and address, where the laboratory testing is performed, the...

  9. Fabrication and laboratory-based performance testing of a building-integrated photovoltaic-thermal roofing panel

    International Nuclear Information System (INIS)

    Chen, Fangliang; Yin, Huiming

    2016-01-01

    Highlights: • A BIPVT solar panel is designed and fabricated for energy efficient buildings. • A high-speed manufacture method is developed to produce the functionally graded materials. • Laboratory tests demonstrate BIPVT’s energy efficiency improvement and innovations. • The PV efficiency is enhanced ∼24% through temperature control of the panel by water flow. • The combined electric and thermal efficiency reaches >75% of solar irradiation. - Abstract: A building integrated photovoltaic-thermal (BIPVT) multifunctional roofing panel has been developed in this study to harvest solar energy in the form of PV electricity as well as heat energy through the collection of warm water. As a key component of the multifunctional building envelope, an aluminum/high-density polyethylene (HDPE) functionally graded material (FGM) panel embedded with aluminum water tubes has been fabricated through the vibration-sedimentation approach. The FGM layer gradually transits material phases from well-conductive side (with aluminum dominated) to another highly insulated side (with HDPE). The heat in the PV cells can be easily transferred into the conductive side of the FGM and then collected by the water flow in the embedded tubes. Therefore, the operational temperature of the PV cells can be significantly lowered down, which recovers the PV efficiency in hot weather. In this way, the developed BIPVT panel is able to efficiently harvest solar energy in the form of both PV electricity and heat. The performance of a prototype BIPVT panel has been evaluated in terms of its thermal efficiency via warm water collection and PV efficiency via the output electricity. The laboratory test results demonstrate that significant energy conversion efficiency improvement can be achieved for both electricity generation and heat collection by the presented BIPVT roofing system. Overall, the performance indicates a very promising prospective of the new BIPVT multifunctional roofing panel.

  10. The SUCCESS model for laboratory performance and execution of rapid molecular diagnostics in patients with sepsis.

    Science.gov (United States)

    Dekmezian, Mhair; Beal, Stacy G; Damashek, Mary Jane; Benavides, Raul; Dhiman, Neelam

    2015-04-01

    Successful performance and execution of rapid diagnostics in a clinical laboratory hinges heavily on careful validation, accurate and timely communication of results, and real-time quality monitoring. Laboratories must develop strategies to integrate diagnostics with stewardship and evidence-based clinical practice guidelines. We present a collaborative SUCCESS model for execution and monitoring of rapid sepsis diagnostics to facilitate timely treatment. Six months after execution of the Verigene Gram-Positive Blood Culture (BC-GP) and the AdvanDx PNA-FISH assays, data were collected on 579 and 28 episodes of bacteremia and fungemia, respectively. Clinical testing was executed using a SUCCESS model comprising the following components: stewardship, utilization of resources, core strategies, concierge services, education, support, and surveillance. Stewardship needs were identified by evaluating the specialty services benefiting from new testing. Utilization of resources was optimized by reviewing current treatment strategies and antibiogram and formulary options. Core strategies consisted of input from infectious disease leadership, pharmacy, and laboratory staff. Concierge services included automated Micro-eUpdate and physician-friendly actionable reports. Education modules were user-specific, and support was provided through a dedicated 24/7 microbiology hotline. Surveillance was performed by daily audit by the director. Using the SUCCESS model, the turnaround time for the detailed report with actionable guidelines to the physician was ∼3 hours from the time of culture positivity. The overall correlation between rapid methods and culture was 94% (546/579). Discrepant results were predominantly contaminants such as a coagulase-negative staphylococci or viridans streptococci in mixed cultures. SUCCESS is a cost-effective and easily adaptable model for clinical laboratories with limited stewardship resources.

  11. Bentonite erosion. Laboratory studies

    Energy Technology Data Exchange (ETDEWEB)

    Jansson, Mats (Div. of Nuclear Chemistry, Royal Inst. of Technology, Stockholm (Sweden), School of Chemical Science and Engineering)

    2009-11-15

    This report covers the laboratory studies that have been performed at Nuclear Chemistry, KTH in the project 'Bentonite Erosion'. Many of the experiments in this report were performed to support the work of the modelling group and were often relatively simple. One of the experiment series was performed to see the impact of gravity and concentration of mono- and di-valent cations. A clay suspension was prepared in a test tube. A net was placed in contact with the suspension, the test tube was filled with solutions of different concentrations and the system was left overnight to settle. The tube was then turned upside down and the behaviour was visually observed. Either the clay suspension fell through the net or stayed on top. By using this method surprisingly sharp determinations of the Critical Coagulation (Flocculation) Concentration (CCC/CFC) could be made. The CCC/CFC of Ca2+ was for sodium montmorillonite determined to be between 1 and 2 mM. An artificial fracture was manufactured in order to simulate the real case scenario. The set-up was two Plexiglas slabs separated by 1 mm thick spacers with a bentonite container at one side of the fracture. Water was pumped with a very low flow rate perpendicular to bentonite container and the water exiting the fracture was sampled and analyzed for colloid content. The bentonite used was treated in different ways. In the first experiment a relatively montmorillonite rich clay was used while in the second bentonite where only the readily soluble minerals had been removed was used. Since Plexiglas was used it was possible to visually observe the bentonite dispersing into the fracture. After the compacted bentonite (1,000 kg/m3) had been water saturated the clay had expanded some 12 mm out into the fracture. As the experiment progressed the clay expanded more out into the fracture and seemed to fractionate in two different phases with less material in the outmost phase. A dark rim which was later analyzed to contain

  12. Comparisons of uniform and discrete source distributions for use in bioassay laboratory performance testing

    International Nuclear Information System (INIS)

    Scherpelz, R.I.; MacLellan, J.A.

    1987-09-01

    The Pacific Northwest Laboratory (PNL) is sending a torso phantom with radioactive material uniformly distributed in the lungs to in vivo bioassay laboratories for analysis. Although the radionuclides ultimately chosen for the studies had relatively long half-lives, future accreditation testing will require repeated tests with short half-life test nuclides. Computer modeling was used to simulate the major components of the phantom. Radiation transport calculations were then performed using the computer models to calculate dose rates either 15 cm from the chest or at its surface. For 144 Ce and 60 Co, three configurations were used for the lung comparison tests. Calculations show that, for most detector positions, a single plug containing 40 K located in the back of the heart provides a good approximation to a uniform distribution of 40 K. The approximation would lead, however, to a positive bias for the detector reading if the detector were located at the chest surface near the center. Loading the 40 K in a uniform layer inside the chest wall is not a good approximation of the uniform distribution in the lungs, because most of the radionuclides would be situated close to the detector location and the only shielding would be the thickness of the chest wall. The calculated dose rates for 60 Co and 144 Ce were similar at all calculated reference points. 3 refs., 5 figs., 10 tabs

  13. To what extent is clinical and laboratory information used to perform medication reviews in the nursing home setting? the CLEAR study

    NARCIS (Netherlands)

    Gonzalvo, Carlota Mestres; Hurkens, Kim P. G. M.; de Wit, Hugo A. j M.; van Oijen, Brigit P. C.; Janknegt, Rob; Schols, Jos M. G. A.; Mulder, Wubbo J.; Verhey, Frans R.; Winkens, Bjorn; van der Kuy, Paul-Hugo M.

    2015-01-01

    Background: The aim of this study was to evaluate to what extent laboratory data, actual medication, medical history, and/or drug indication influence the quality of medication reviews for nursing home patients. Methods: Forty-six health care professionals from different fields were requested to

  14. Variability of creatinine measurements in clinical laboratories: results from the CRIC study.

    Science.gov (United States)

    Joffe, Marshall; Hsu, Chi-yuan; Feldman, Harold I; Weir, Matthew; Landis, J R; Hamm, L Lee

    2010-01-01

    Estimating equations using serum creatinine (SCr) are often used to assess glomerular filtration rate (GFR). Such creatinine (Cr)-based formulae may produce biased estimates of GFR when using Cr measurements that have not been calibrated to reference laboratories. In this paper, we sought to examine the degree of this variation in Cr assays in several laboratories associated with academic medical centers affiliated with the Chronic Renal Insufficiency Cohort (CRIC) Study; to consider how best to correct for this variation, and to quantify the impact of such corrections on eligibility for participation in CRIC. Variability of Cr is of particular concern in the conduct of CRIC, a large multicenter study of subjects with chronic renal disease, because eligibility for the study depends on Cr-based assessment of GFR. A library of 5 large volume plasma specimens from apheresis patients was assembled, representing levels of plasma Cr from 0.8 to 2.4 mg/dl. Samples from this library were used for measurement of Cr at each of the 14 CRIC laboratories repetitively over time. We used graphical displays and linear regression methods to examine the variability in Cr, and used linear regression to develop calibration equations. We also examined the impact of the various calibration equations on the proportion of subjects screened as potential participants who were actually eligible for the study. There was substantial variability in Cr assays across laboratories and over time. We developed calibration equations for each laboratory; these equations varied substantially among laboratories and somewhat over time in some laboratories. The laboratory site contributed the most to variability (51% of the variance unexplained by the specimen) and variation with time accounted for another 15%. In some laboratories, calibration equations resulted in differences in eligibility for CRIC of as much as 20%. The substantial variability in SCr assays across laboratories necessitates calibration

  15. Tracking the train of thought from the laboratory into everyday life: An experience-sampling study of mind wandering across controlled and ecological contexts

    Science.gov (United States)

    McVay, Jennifer C.; Kane, Michael J.; Kwapil, Thomas R.

    2009-01-01

    In an experience-sampling study that bridged laboratory, ecological, and individual-differences approaches to mind-wandering research, 72 subjects completed an executive-control task with periodic thought probes (reported by McVay & Kane, 2009) and then carried PDAs for a week that signaled them 8 times daily to report immediately whether their thoughts were off-task. Subjects who reported more mind wandering during the laboratory task endorsed more mind-wandering experiences during everyday life (and were more likely to report worries as off-task thought content). We also conceptually replicated laboratory findings that mind wandering predicts task performance: subjects rated their daily-life performance to be impaired when they reported off-task thoughts, with greatest impairment when subjects’ mind wandering lacked meta-consciousness. The propensity to mind-wander appears to be a stable cognitive characteristic and seems to predict performance difficulties in daily life, just as it does in the laboratory. PMID:19815789

  16. Exploring the Potential of Smartphones and Tablets for Performance Support in Food Chemistry Laboratory Classes

    Science.gov (United States)

    van der Kolk, Koos; Hartog, Rob; Beldman, Gerrit; Gruppen, Harry

    2013-12-01

    Increasingly, mobile applications appear on the market that can support students in chemistry laboratory classes. In a multiple app-supported laboratory, each of these applications covers one use-case. In practice, this leads to situations in which information is scattered over different screens and written materials. Such a multiple app-supported laboratory will become awkward with the growth of the number of applications and use cases. In particular, using and switching between applications is likely to induce extraneous cognitive load that can easily be avoided. The manuscript describes the design of a prototype smartphone web app (LabBuddy) designed to support students in food chemistry laboratory classes. The manuscript describes a case study ( n = 26) of the use of a LabBuddy prototype in such a laboratory class. Based on the evaluation of this case study, design requirements for LabBuddy were articulated. LabBuddy should work on HTML5 capable devices, independent of screen size, by having a responsive layout. In addition, LabBuddy should enable a student using LabBuddy to switch between devices without much effort. Finally, LabBuddy should offer an integrated representation of information.

  17. Laboratory-based performance evaluation of PIMA CD4+ T-lymphocyte count point-of-care by lay-counselors in Kenya.

    Science.gov (United States)

    Zeh, Clement; Rose, Charles E; Inzaule, Seth; Desai, Mitesh A; Otieno, Fredrick; Humwa, Felix; Akoth, Benta; Omolo, Paul; Chen, Robert T; Kebede, Yenew; Samandari, Taraz

    2017-09-01

    CD4+ T-lymphocyte count testing at the point-of-care (POC) may improve linkage to care of persons diagnosed with HIV-1 infection, but the accuracy of POC devices when operated by lay-counselors in the era of task-shifting is unknown. We examined the accuracy of Alere's Pima™ POC device on both capillary and venous blood when performed by lay-counselors and laboratory technicians. In Phase I, we compared the perfomance of POC against FACSCalibur™ for 280 venous specimens by laboratory technicians. In Phase II we compared POC performance by lay-counselors versus laboratory technicians using 147 paired capillary and venous specimens, and compared these to FACSCalibur™. Statistical analyses included Bland-Altman analyses, concordance correlation coefficient, sensitivity, and specificity at treatment eligibility thresholds of 200, 350, and 500cells/μl. Phase I: POC sensitivity and specificity were 93.0% and 84.1% at 500cells/μl, respectively. Phase II: Good agreement was observed for venous POC results from both lay-counselors (concordance correlation coefficient (CCC)=0.873, bias -86.4cells/μl) and laboratory technicians (CCC=0.920, bias -65.7cells/μl). Capillary POC had good correlation: lay-counselors (CCC=0.902, bias -71.2cells/μl), laboratory technicians (CCC=0.918, bias -63.0cells/μl). Misclassification at the 500 cells/μl threshold for venous blood was 13.6% and 10.2% for lay-counselors and laboratory technicians and 12.2% for capillary blood in both groups. POC tended to under-classify the CD4 values with increasingly negative bias at higher CD4 values. Pima™ results were comparable to FACSCalibur™ for both venous and capillary specimens when operated by lay-counselors. POC CD4 testing has the potential to improve linkage to HIV care without burdening laboratory technicians in resource-limited settings. Published by Elsevier B.V.

  18. Laboratory studies on the effect of freezing and thawing exposure on bentonite buffer performance: Closed-system tests

    Energy Technology Data Exchange (ETDEWEB)

    Schatz, T.; Martikainen, J. [B and Tech Oy, Helsinki (Finland)

    2010-12-15

    This report presents a set of results from laboratory studies on the effect of freezing and thawing on compacted bentonite buffer material. In order to evaluate the effect of freezing and thawing on compacted bentonite buffer performance a series of experiments were conducted using closed, constant-volume cells as follows: Pre- and post-freezing swelling pressure measurements were performed on fully saturated MX-80 and Deponit CA-N bentonite samples, at dry density values of approximately 1.6 g/cm{sup 3}, over five freeze/thaw cycles from room temperature to -18 deg C with rapid (instantaneous) temperature exposure. Pressure measurements were performed on fully saturated MX-80 bentonite samples, at dry density values of 1.470 and 1.501 g/cm{sup 3}, during a temperature run from room temperature to -10 deg C with step-change temperature exposure and back from -10 deg C to room temperature under continuous temperature change exposure at 0.1 deg C/h. Pressure measurements were performed on fully saturated MX-80 bentonite samples, encompassing a range of dry density values from 0.940 to 1.534 g/cm{sup 3}, during repeated temperature runs from room temperature to -10 deg C and back with continuous temperature change exposure at 0.1 deg C/h. Pressure measurements were performed on a fully saturated Deponit CA-N bentonite sample, at a dry density of 1.484 g/cm{sup 3}, during a temperature run from room temperature to -10 deg C and back with continuous temperature change exposure at 0.1 deg C/h. In some cases, hydraulic conductivity measurements were performed before and after freeze/thaw exposure. In general, exposure to freezing temperatures, down to an average temperature of -10 deg C, results in the development of significant internal pressures in compacted bentonite samples, which is attributed to the formation of ice. The specific test results are summarised as follows: Increases in pressure by factors of 1.5 to 2.2 were observed for MX-80 samples at dry densities

  19. Project management plan for the gunite and associated tanks treatability studies project at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1995-12-01

    This plan for the Gunite and Associated Tanks (GAAT) Treatability Studies Project satisfies the requirements of the program management plan for the Oak Ridge National Laboratory (ORNL) Environmental Restoration (ER) Program as established in the Program Management Plan for the Martin Marietta Energy Systems, Inc., Oak Ridge National Laboratory Site Environmental Restoration Program. This plan is a subtier of several other ER documents designed to satisfy the US Department of Energy (DOE) Order 4700.1 requirement for major systems acquisitions. This project management plan identifies the major activities of the GAAT Treatability Studies Project; establishes performance criteria; discusses the roles and responsibilities of the organizations that will perform the work; and summarizes the work breakdown structure, schedule, milestones, and cost estimate for the project

  20. Fresh biological reference materials. Use in inter laboratory studies and as CRMs

    International Nuclear Information System (INIS)

    De Boer, J.

    1999-01-01

    Biological reference materials were prepared and packed in tins and glass jars to be used in inter laboratory studies on chlorobiphenyls and organochlorine pesticides, and trace metals, respectively. The materials were homogenised, sterilised and packed as wet tissue, which is unique for the purpose of inter laboratory studies and offers the advantage of studying the extraction and destruction steps of the analytical methods. In addition to their use in inter laboratory studies, some materials have been prepared or are being prepared as certified reference material for chlorobiphenyl analysis. (author)

  1. Going GLP: Conducting Toxicology Studies in Compliance with Good Laboratory Practices.

    Science.gov (United States)

    Carroll, Erica Eggers

    2016-01-01

    Good laboratory practice standards are US federal regulations enacted as part of the Federal Insecticide, Fungicide, and Rodenticide Act (40 CFR Part 160), the Toxic Substance Control Act (40 CFR Part 792), and the Good Laboratory Practice for Nonclinical Laboratory Studies (21 CFR Part 58) to support protection of public health in the areas of pesticides, chemicals, and drug investigations in response to allegations of inaccurate data acquisition. Essentially, good laboratory practices (GLPs) are a system of management controls for nonclinical research studies involving animals to ensure the uniformity, consistency, reliability, reproducibility, quality, and integrity of data collected as part of chemical (including pharmaceuticals) tests, from in vitro through acute to chronic toxicity tests. The GLPs were established in the United States in 1978 as a result of the Industrial Bio-Test Laboratory scandal which led to congressional hearings and actions to prevent fraudulent data reporting and collection. Although the establishment of infrastructure for GLPs compliance is labor-intensive and time-consuming, achievement and maintenance of GLP compliance ensures the accuracy of the data collected from each study, which is critical for defending results, advancing science, and protecting human and animal health. This article describes how and why those in the US Army Medical Department responsible for protecting the public health of US Army and other military personnel made the policy decision to have its toxicology laboratory achieve complete compliance with GLP standards, the first such among US Army laboratories. The challenges faced and how they were overcome are detailed.

  2. Dynamics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Dynamics Lab replicates vibration environments for every Navy platform. Testing performed includes: Flight Clearance, Component Improvement, Qualification, Life...

  3. Defining a roadmap for harmonizing quality indicators in Laboratory Medicine: a consensus statement on behalf of the IFCC Working Group "Laboratory Error and Patient Safety" and EFLM Task and Finish Group "Performance specifications for the extra-analytical phases".

    Science.gov (United States)

    Sciacovelli, Laura; Panteghini, Mauro; Lippi, Giuseppe; Sumarac, Zorica; Cadamuro, Janne; Galoro, César Alex De Olivera; Pino Castro, Isabel Garcia Del; Shcolnik, Wilson; Plebani, Mario

    2017-08-28

    The improving quality of laboratory testing requires a deep understanding of the many vulnerable steps involved in the total examination process (TEP), along with the identification of a hierarchy of risks and challenges that need to be addressed. From this perspective, the Working Group "Laboratory Errors and Patient Safety" (WG-LEPS) of International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) is focusing its activity on implementation of an efficient tool for obtaining meaningful information on the risk of errors developing throughout the TEP, and for establishing reliable information about error frequencies and their distribution. More recently, the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has created the Task and Finish Group "Performance specifications for the extra-analytical phases" (TFG-PSEP) for defining performance specifications for extra-analytical phases. Both the IFCC and EFLM groups are working to provide laboratories with a system to evaluate their performances and recognize the critical aspects where improvement actions are needed. A Consensus Conference was organized in Padova, Italy, in 2016 in order to bring together all the experts and interested parties to achieve a consensus for effective harmonization of quality indicators (QIs). A general agreement was achieved and the main outcomes have been the release of a new version of model of quality indicators (MQI), the approval of a criterion for establishing performance specifications and the definition of the type of information that should be provided within the report to the clinical laboratories participating to the QIs project.

  4. ISO 15189 accreditation: Requirements for quality and competence of medical laboratories, experience of a laboratory I.

    Science.gov (United States)

    Guzel, Omer; Guner, Ebru Ilhan

    2009-03-01

    Medical laboratories are the key partners in patient safety. Laboratory results influence 70% of medical diagnoses. Quality of laboratory service is the major factor which directly affects the quality of health care. The clinical laboratory as a whole has to provide the best patient care promoting excellence. International Standard ISO 15189, based upon ISO 17025 and ISO 9001 standards, provides requirements for competence and quality of medical laboratories. Accredited medical laboratories enhance credibility and competency of their testing services. Our group of laboratories, one of the leading institutions in the area, had previous experience with ISO 9001 and ISO 17025 Accreditation at non-medical sections. We started to prepared for ISO 15189 Accreditation at the beginning of 2006 and were certified in March, 2007. We spent more than a year to prepare for accreditation. Accreditation scopes of our laboratory were as follows: clinical chemistry, hematology, immunology, allergology, microbiology, parasitology, molecular biology of infection serology and transfusion medicine. The total number of accredited tests is 531. We participate in five different PT programs. Inter Laboratory Comparison (ILC) protocols are performed with reputable laboratories. 82 different PT Program modules, 277 cycles per year for 451 tests and 72 ILC program organizations for remaining tests have been performed. Our laboratory also organizes a PT program for flow cytometry. 22 laboratories participate in this program, 2 cycles per year. Our laboratory has had its own custom made WEB based LIS system since 2001. We serve more than 500 customers on a real time basis. Our quality management system is also documented and processed electronically, Document Management System (DMS), via our intranet. Preparatory phase for accreditation, data management, external quality control programs, personnel related issues before, during and after accreditation process are presented. Every laboratory has

  5. Emergency department visual urinalysis versus laboratory urinalysis.

    Science.gov (United States)

    Worrall, James C

    2009-11-01

    The primary objective of this study was to compare the results of nurse-performed urinalysis (NPU) interpreted visually in the emergency department (ED) with laboratory performed urinalysis (LPU) interpreted by reflectance photometry. This was a prospective observational study based on a convenience sample from my emergency practice. Emergency nurses, who were unaware of the study, performed usual dipstick analysis before sending the same urine sample to the laboratory for testing. Of 140 urinalyses performed during the study period, 124 were suitable for analysis. When compared with the reference standard LPU, the NPU had an overall sensitivity of 100% (95% confidence interval [CI] 95%-100%) and a specificity of 49% (95% CI 33%-65%) for the presence of any 1 of blood, leukocyte esterase, nitrites, protein, glucose or ketones in the urine. Of 20 falsely positive NPUs, 18 were a result of the nurse recording 1 or more components as "trace" positive. Although NPU does not yield identical results to LPU, a negative LPU is expected when the initial NPU in the ED is negative.

  6. Errors in laboratory medicine: practical lessons to improve patient safety.

    Science.gov (United States)

    Howanitz, Peter J

    2005-10-01

    Patient safety is influenced by the frequency and seriousness of errors that occur in the health care system. Error rates in laboratory practices are collected routinely for a variety of performance measures in all clinical pathology laboratories in the United States, but a list of critical performance measures has not yet been recommended. The most extensive databases describing error rates in pathology were developed and are maintained by the College of American Pathologists (CAP). These databases include the CAP's Q-Probes and Q-Tracks programs, which provide information on error rates from more than 130 interlaboratory studies. To define critical performance measures in laboratory medicine, describe error rates of these measures, and provide suggestions to decrease these errors, thereby ultimately improving patient safety. A review of experiences from Q-Probes and Q-Tracks studies supplemented with other studies cited in the literature. Q-Probes studies are carried out as time-limited studies lasting 1 to 4 months and have been conducted since 1989. In contrast, Q-Tracks investigations are ongoing studies performed on a yearly basis and have been conducted only since 1998. Participants from institutions throughout the world simultaneously conducted these studies according to specified scientific designs. The CAP has collected and summarized data for participants about these performance measures, including the significance of errors, the magnitude of error rates, tactics for error reduction, and willingness to implement each of these performance measures. A list of recommended performance measures, the frequency of errors when these performance measures were studied, and suggestions to improve patient safety by reducing these errors. Error rates for preanalytic and postanalytic performance measures were higher than for analytic measures. Eight performance measures were identified, including customer satisfaction, test turnaround times, patient identification

  7. Understanding the interface between clinical and laboratory staff

    Directory of Open Access Journals (Sweden)

    Ankie van den Broek

    2014-07-01

    Objectives: To propose a new conceptual model to gain insight and analyse factors that influence the laboratory–clinical staff interface. Methods: To develop the conceptual model, a literature study was performed, regulatory guidelines and standards for laboratories were analysed and discussions were held with experts on the topic. Result: A conceptual model and analytical framework provided good guidance in understanding and assessing the organisational and personal factors shaping the interface. The model was based on three elements: (1 the three phases of communication (pre-analytical, analytical and post-analytical; (2 the organisational and personal factors of interaction; and (3 the socio-political, economic and cultural context in which clinicians and laboratory staff operate. Conclusion: Assessment of the interface between clinicians and laboratory workers can be performed in a systematic way. Applying this model will provide information to managers of health institutions and heads of laboratories and clinical departments about what happens when clinicians and laboratory staff interact, thus aiding them in designing strategies to improve this interface.

  8. An experimental paradigm to compare motor performance under laboratory and under everyday-like conditions.

    Science.gov (United States)

    Bock, Otmar; Hagemann, Anne

    2010-10-30

    Research findings on human motor skills may not necessarily hold in everyday life, since laboratory and everyday scenarios typically differ with respect to the subjects' attention to the skill, their motivation to perform at their best, the goals they try to achieve, and the mode of movement initiation - extrinsic versus intrinsic. Here we present an experimental approach which can be used to substantiate the hypothesized effects of laboratory (L) versus everyday (E) settings on one type of motor skill, i.e., manual prehension. This approach is based on two tasks: In task L, subjects are told that they will participate in an experiment on grasping, and are instructed to seize and move a lever upon appearance of a visual target. In task E, they are told that they will play a computer game, and they have to seize and move the lever in order to proceed from one game level to the next. Both tasks include prehension movements from the same starting position and object to the same terminal position and object; movements differ only in their behavioural context. We exemplify the utility of our approach with a preliminary analysis of kinematic and force data. It shows that the two tasks differ with respect to several performance measures, and that some performance measures make independent contributions to that difference. The existence of independent contributions suggests that behavioural context may influence prehension via several distinct routes. Our approach can be used for comprehensive analyses of the context-dependence of motor skills in various reference groups. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Semiconductor laser joint study program with Rome Laboratory

    Science.gov (United States)

    Schaff, William J.; Okeefe, Sean S.; Eastman, Lester F.

    1994-09-01

    A program to jointly study vertical-cavity surface emitting lasers (VCSEL) for high speed vertical optical interconnects (VOI) has been conducted under an ES&E between Rome Laboratory and Cornell University. Lasers were designed, grown, and fabricated at Cornell University. A VCSEL measurement laboratory has been designed, built, and utilized at Rome Laboratory. High quality VCSEL material was grown and characterized by fabricating conventional lateral cavity lasers that emitted at the design wavelength of 1.04 microns. The VCSEL's emit at 1.06 microns. Threshold currents of 16 mA at 4.8 volts were obtained for 30 microns diameter devices. Output powers of 5 mW were measured. This is 500 times higher power than from the light emitting diodes employed previously for vertical optical interconnects. A new form of compositional grading using a cosinusoidal function has been developed and is very successful for reducing diode series resistance for high speed interconnection applications. A flip-chip diamond package compatible with high speed operation of 16 VCSEL elements has been designed and characterized. A flip-chip device binding effort at Rome Laboratory was also designed and initiated. This report presents details of the one-year effort, including process recipes and results.

  10. School physics teacher class management, laboratory practice, student engagement, critical thinking, cooperative learning and use of simulations effects on student performance

    Science.gov (United States)

    Riaz, Muhammad

    The purpose of this study was to examine how simulations in physics class, class management, laboratory practice, student engagement, critical thinking, cooperative learning, and use of simulations predicted the percentage of students achieving a grade point average of B or higher and their academic performance as reported by teachers in secondary school physics classes. The target population consisted of secondary school physics teachers who were members of Science Technology, Engineeering and,Mathematics Teachers of New York City (STEMteachersNYC) and American Modeling Teachers Association (AMTA). They used simulations in their physics classes in the 2013 and 2014 school years. Subjects for this study were volunteers. A survey was constructed based on a literature review. Eighty-two physics teachers completed the survey about instructional practice in physics. All respondents were anonymous. Classroom management was the only predictor of the percent of students achieving a grade point average of B or higher in high school physics class. Cooperative learning, use of simulations, and student engagement were predictors of teacher's views of student academic performance in high school physics class. All other variables -- class management, laboratory practice, critical thinking, and teacher self-efficacy -- were not predictors of teacher's views of student academic performance in high school physics class. The implications of these findings were discussed and recommendations for physics teachers to improve student learning were presented.

  11. Communication and laboratory performance in parapsychology experiments: demand characteristics and the social organization of interaction.

    Science.gov (United States)

    Wooffitt, Robin

    2007-09-01

    This paper reports findings from a conversation analytic study of experimenter-participant interaction in parapsychology experiments. It shows how properties of communication through which the routine business of the experiment is conducted may have an impact on the research participant's subsequent performance. In this, the study explores social psychological features of the psychology laboratory. In particular, it examines aspects of Orne's (1962) account of what he called the demand characteristics of the psychological experiment. The data come from a corpus of audio recordings of experimenter-participant interaction during experiments on extra-sensory perception. These kinds of experiments, and the phenomena they purport to study, are undoubtedly controversial; however, the paper argues that there are grounds for social psychologists to consider parapsychology experiments as a class (albeit distinctive) of psychology experiments, and, therefore, as sites in which general social psychological and communicative phenomena can be studied. The empirical sections of the paper examine interaction during part of the experimental procedure when the experimenter verbally reviews a record of the participant's imagery reported during an earlier part of the experiment. The analysis shows that the way in which the experimenter acknowledges the research participants' utterances may be significant for the trajectory of the experiment and explores how the participants' subsequent performance in the experiment may be influenced by interactionally generated contingencies.

  12. Results of the Interlaboratory Exercise CSN/CIEMAT-02 Among Environmental Radioactivity Laboratories (Sea Fish)

    International Nuclear Information System (INIS)

    Romero Gonzalez, M.L.

    2003-01-01

    The document describes the outcome of the CSN/CIEMAT-02 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories. The test sample was a reference materials provided by the IAEA-MEL (IAE Marine Environmental Laboratory, Monaco), a sea fish containing environmental levels of U-238, U-234, K-40, Pb-210, Ra-226, Sr-90, Cs-137, Co-60, Pu-(239+240), Am-241 and Tc-99. The results of the exercise were computed for 32 participating laboratories, and their analytical performance was assessed using the z-score approach. A raised percentage of satisfactory laboratory performance has been obtained for all the analysis, being the best performance in gamma measurements. The laboratories have made an effort to calculate the combined uncertainty of the radiochemical determinations. Most of the laboratories have demonstrated its competence in performing the study analysis and also the adequate measuring capability of their detection equipment even in conditions close to detection limits. The study has shown the capacity of participant laboratories to perform radioactive determinations in environmental sea fish samples with satisfactory quality levels. (Author) 6 refs

  13. Indicadores de desempenho em um laboratório de diagnóstico animal = Performance indicators in an animal diagnostic laboratory

    Directory of Open Access Journals (Sweden)

    Sílvio Orlan de Castro Chaves

    2018-06-01

    Full Text Available A utilização dos indicadores da qualidade vem sendo estimulada nos laboratórios para melhorar a qualificaçã o e a quantificaçã o dos erros nos diferentes processos laboratoriais, bem como para ajudar na implantaçã o de medidas corretivas e preventivas e indicar a eficá cia das açõ es realizadas. Este trabalho tem como objetivo avaliar indicadores de desempenho durante o ano de 2015 e de 2016 em um laboratório de diagnóstico animal localizado em Belém, estado do Pará. Dessa forma, utilizou-se quatro indicadores de desempenho do laboratório: nú mero de açõ es de divulgaçã o do laboratório para sociedade; desempenho temporal; percentual de ensaios acreditados e percentual de execução do plano de capacitação. Todos os ensaios ofertados pelo laboratório são acreditados na ABNT NBR ISO/IEC 17025:2005. Verificou-se que não houve ações de divulgação do laboratório no ano de 2015, entretanto, no ano de 2016, ocorreram sete ações de divulgação do laboratório em diferentes estados do Brasil. As amostras com relatórios de ensaio fornecidos dentro do prazo estipulado para os clientes decresceram 1,5% entre o ano de 2015 (92,7% para 2016 (91,2%. O percentual de capacitação dos funcionários foi nulo no ano de 2015 (0% e pouco expressivo em 2016 (16,7%. Conclui-se que o laboratório em estudo apresenta bons indicadores de desempenho temporal e de acreditação, porém deve atentar para melhoria continua das ações futuras de divulgação da instituição e para o treinamento de pessoal a fim de atender plenamente o planejamento estratégico do órgão. = The use of quality indicators has been valued in the management of laboratories to optimize the qualification and quantification of failures in different laboratory processes, as well as to assist in the implementation of corrective and preventive measures and to indicate the effectiveness of the actions taken. This study aims to evaluate key

  14. Electric air filtration: theory, laboratory studies, hardware development, and field evaluations

    International Nuclear Information System (INIS)

    Bergman, W.; Biermann, A.; Kuhl, W.

    1983-09-01

    We summarize the results of a seven-year research project for the US Department of Energy (DOE) to develop electric air filters that extend the service life of high-efficiency particulate air (HEPA) filters used in the nuclear industry. This project was unique to Lawrence Livermore National Laboratory (LLNL), and it entailed comprehensive theory, laboratory studies, and hardware development. We present our work in three major areas: (1) theory of and instrumentation for filter test methods, (2) theoretical and laboratory studies of electric air filters, and (3) development and evaluation of eight experimental electric air filters

  15. Psychology Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — This facility provides testing stations for computer-based assessment of cognitive and behavioral Warfighter performance. This 500 square foot configurable space can...

  16. A comparison of results from two mycology laboratories for the diagnosis of onychomycosis: a study of 85 cases in a geriatric population.

    Science.gov (United States)

    Scherer, William P; Scherer, Michael D

    2004-01-01

    An investigative study was performed to compare the results from two mycology laboratories for the diagnosis of onychomycosis in a geriatric population and to determine the possible pharmacologic treatments based on the two laboratories' results. In this study, 85 cases of suspected onychomycosis involving men and women 65 years and older from a nursing home setting in South Florida were used. Samples were taken from the hallux toenail and sent to two different mycology laboratories for fluorescent potassium hydroxide preparation and microscopic examination of a fungal culture. Of the 85 cases studied, the two mycology laboratories reported similar potassium hydroxide preparation results for 58.8% of the patients and similar fungal culture results for genus and species identification for 37.6% of the patients. When the potassium hydroxide preparation and fungal culture results were combined, the two mycology laboratories reported similar results for only 27.1% of the patients. As a result of the two mycology laboratories' findings, the possible US Food and Drug Administration-approved pharmacologic treatments may differ for 43.5% of the patients studied. The discrepancy between the two independent laboratories leaves physicians to question the reproducibility of fluorescent potassium hydroxide preparation and fungal culture analysis in a geriatric patient population for the diagnosis of onychomycosis.

  17. Comparing the performance characteristics of CSF-TRUST and CSF-VDRL for syphilis: a cross-sectional study

    OpenAIRE

    Gu, Weiming; Yang, Yang; Wu, Lei; Yang, Sheng; Ng, Lai-King

    2013-01-01

    Objective In this study, we aimed to determine the performance characteristics of toluidine red unheated serum test on cerebrospinal fluids (CSF-TRUST) as compared to venereal disease research laboratory test on cerebrospinal fluids (CSF-VDRL) for laboratory the diagnosis of neurosyphilis. Design A cross-sectional study. Setting Sexually transmitted infections (STIs) clinics. Participants and methods CSF and serum samples were collected from 824 individual STD clinic patients who have syphili...

  18. Effect of urban noise to the acoustical performance of the secondary school’s learning spaces - A case study in Batu Pahat.

    Science.gov (United States)

    Tong, Y. G.; Abu Bakar, H.; Mohd. Sari, K. A.; Ewon, U.; Labeni, M. N.; Fauzan, N. F. A.

    2017-11-01

    Classrooms and laboratories are important spaces that use for teaching and learning process in the school. Therefore, good acoustical performances of these spaces are essential to ensure the speech or message from the teacher can be delivered to the students effectively and clearly. The aims of this study is to determine the acoustical performance of the teaching and learning spaces in public school that situated near to the traffic roads. The acoustical performance of the classrooms and laboratories at Sekolah Menengah Kebangsaan Convent Batu Pahat was evaluated in this study. The reverberation time and ambient noise of these learning spaces which are the main parameters for classroom design criteria were evaluated. Field measurements were carried out inside six classrooms and four laboratories unoccupied furnished according to the international standards. The acoustical performances of the tested learning spaces were poor where the noise criteria and reverberation times inside the measured classrooms and laboratories were higher than recommended values.

  19. Process performance of the pilot-scale in situ vitrification of a simulated waste disposal site at the Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Carter, J.G.; Koegler, S.S.; Bates, S.O.

    1988-06-01

    Process feasibility studies have been successfully performed on three developmental scales to determine the potential for applying in situ vitrification to intermediate-level (low-level) waste placed in seepage pits and trenches at Oak Ridge National Laboratory (ORNL). In the laboratory, testing was performed in crucibles containing a mixture of 50% ORNL soil and 50% limestone. In an engineering-scale test at Pacific Northwest Laboratory a /1/12/-scale simulation of an ORNL waste trench was constructed and vitrified, resulting in a waste product containing soil and limestone concentrations of 68 wt % and 32 wt %, respectively. In the pilot-scale test a /3/8/-scale simulation of the same trench was constructed and vitrified at ORNL, resulting in soil and limestone concentrations of 80% and 20%, respectively, in the waste product. Results of the three scales of testing indicate that the ORNL intermediate-level (low-level) waste sites can be successfully processed by in situ vitrification; the waste form will retain significant quantities of the cesium and strontium. Because cesium-137 and strontium-90 are the major components of the radionuclide inventory in the ORNL seepage pits and trenches, final field process decontamination factors (i.e., losses to the off-gas system relative to the waste inventory) of 1.0 E + 4 are desired to minimize activity buildup in the off-gas system. 17 refs., 34 figs., 13 tabs

  20. Laboratory hemostasis: milestones in Clinical Chemistry and Laboratory Medicine.

    Science.gov (United States)

    Lippi, Giuseppe; Favaloro, Emmanuel J

    2013-01-01

    Hemostasis is a delicate, dynamic and intricate system, in which pro- and anti-coagulant forces cooperate for either maintaining blood fluidity under normal conditions, or else will prompt blood clot generation to limit the bleeding when the integrity of blood vessels is jeopardized. Excessive prevalence of anticoagulant forces leads to hemorrhage, whereas excessive activation of procoagulant forces triggers excessive coagulation and thrombosis. The hemostasis laboratory performs a variety of first, second and third line tests, and plays a pivotal role in diagnostic and monitoring of most hemostasis disturbances. Since the leading targets of Clinical Chemistry and Laboratory Medicine include promotion of progress in fundamental and applied research, along with publication of guidelines and recommendations in laboratory diagnostics, this journal is an ideal source of information on current developments in the laboratory technology of hemostasis, and this article is aimed to celebrate some of the most important and popular articles ever published by the journal in the filed of laboratory hemostasis.

  1. ABACC's laboratory intercomparison program

    International Nuclear Information System (INIS)

    Almeida, Gevaldo L. de; Esteban, Adolfo; Almeida, Silvio G. de; Araujo, Radier M. de; Rocha, Zildete

    1996-01-01

    A Laboratory Intercomparison Program involving Brazilian and Argentine laboratories, with the special participation of New Brunswick Laboratory - DOE and IAEA Seibersdorf Safeguards Laboratory, was implanted by ABACC having as main purpose to qualify a network to provide analytical services to this Agency on its role as administrator of the Common System of Accountability and Control of Nuclear Materials. For the first round robin of this Program, 15 laboratories were invited to perform elemental analysis on UO 2 samples, by using any desired method. Thirteen confirmed the participation and 10 reported the results. After an evaluation of the results by using a Two-Way Variance Analysis applied to a nested error model, it was found that 5 of them deviate less than 0.1% from the reference value established for the UO 2 uranium contents, being thus situated within the limits adopted for the target values, while the remaining ones reach a maximal deviation of 0.44%. The outcome of this evaluation, was sent to the laboratories, providing them with a feedback to improve their performance by applying corrective actions to the detected sources of errors or bias related to the methods techniques and procedures. (author)

  2. Influence Model Assisted Learning Cycle Mind Map to Achievement Physics Laboratory Judging from the performance Grade VIII SMPN 1 Rejoso Pasuruan

    OpenAIRE

    Ary Analisa Rahma

    2014-01-01

    Pengaruh Model Siklus Belajar Berbantuan Mind Map terhadap Prestasi Belajar Fisika Ditinjau dari Kinerja Laboratorium Siswa Kelas VIII SMPN 1 Rejoso Kabupaten Pasuruan Abstract: This study aimed to examine the effect of the learning cycle models aided the mind map on the learning achievement in terms of the performance of laboratory physics class VIII student on light material in SMP Negeri 1 Rejoso Pasuruan. This study is a quasi-experimental research. The research design used is a 2 x 2...

  3. Moving out of the laboratory: does nicotine improve everyday attention?

    Science.gov (United States)

    Rusted, J M; Caulfield, D; King, L; Goode, A

    2000-11-01

    The most robust demonstrations of the nicotine-related performance effects on human cognitive processes are seen in tasks that measure attention. If nicotine does have some potential for enhancing attention, the obvious question to ask is whether the effects demonstrated in the laboratory hold any significance for real-life performance. This paper describes three studies that compare the effects in smokers of a single own brand cigarette on laboratory tests of attention and on everyday analogues of these laboratory tasks. In the laboratory measures of sustained attention and in the everyday analogue, performance advantages were registered in the smoking condition. These benefits were observed in smokers who abstained for a self-determined period of not less than 2 h. The studies were unable to replicate previous research reporting positive effects of smoking on a laboratory task of selective attention, the Stroop task. Small but significant improvements in performance were registered in the everyday analogues, which involved sustaining attention in a dual task situation, a telephone directory search task and a map search task. In addition, smokers showed a significant colour-naming decrement for smoking-related stimuli in the Stroop task. This attentional bias towards smoking-related words occurred independent of whether they had abstained or recently smoked an own brand cigarette. The effect is discussed in terms of the two-component model of processing bias for emotionally valenced stimuli.

  4. Zero-Gravity Atmospheric Cloud Physics Experiment Laboratory engineering concepts/design tradeoffs. Volume 1: Study results

    Science.gov (United States)

    Greco, R. V.; Eaton, L. R.; Wilkinson, H. C.

    1974-01-01

    The work is summarized which was accomplished from January 1974 to October 1974 for the Zero-Gravity Atmospheric Cloud Physics Laboratory. The definition and development of an atmospheric cloud physics laboratory and the selection and delineation of candidate experiments that require the unique environment of zero gravity or near zero gravity are reported. The experiment program and the laboratory concept for a Spacelab payload to perform cloud microphysics research are defined. This multimission laboratory is planned to be available to the entire scientific community to utilize in furthering the basic understanding of cloud microphysical processes and phenomenon, thereby contributing to improved weather prediction and ultimately to provide beneficial weather control and modification.

  5. Cometabolic biotreatment of TCE-contaminated groundwater: Laboratory and bench-scale development studies

    International Nuclear Information System (INIS)

    Donaldson, T.L.; Jennings, H.L.; Lucero, A.J.; Strandberg, G.W.; Morris, M.I.; Palumbo, A.V.; Boerman, P.A.; Tyndall, R.L.

    1992-01-01

    The Oak Ridge National Laboratory is conducting a demonstration of two cometabolic technologies for biotreatment of groundwater contaminated with trichloroethylene (TCE) and other organics. Technologies based on methanotrophic (methane-utilizing) and toluene-degrading microorganisms will be compared side-by-side on the same groundwater stream. Laboratory and bench-scale bioreactor studies have been conducted to guide selection of microbial cultures and operating conditions for the field demonstration. This report presents the results of the laboratory and bench-scale studies for the methanotrophic system

  6. San Francisco District Laboratory (SAN)

    Data.gov (United States)

    Federal Laboratory Consortium — Program CapabilitiesFood Analysis SAN-DO Laboratory has an expert in elemental analysis who frequently performs field inspections of materials. A recently acquired...

  7. Laboratory Animal Sciences Program (LASP)

    Data.gov (United States)

    Federal Laboratory Consortium — The Laboratory Animal Sciences Program (LASP) is a comprehensive resource for scientists performing animal-based research to gain a better understanding of cancer,...

  8. High Performance Fuel Laboratory, Hanford Reservation, Richland, Washington. Final environmental impact statement

    International Nuclear Information System (INIS)

    1977-09-01

    The High Performance Fuel Laboratory (HPFL) will provide pilot scale tests of manufacturing processes, equipment, and handling systems and of accountability and safeguards, methods, and equipment while keeping radiological and chemical exposures of the workers, public, and environment at the lowest practicable levels. The experience gained from designing, constructing and operating the HPFL can be used in future commitments to commercial fuel fabrication plants in the late 1980s and beyond for processing of nuclear fuel. The HPFL site is located in the 400 Area of the 559-square mile, federally owned Hanford Reservation. This environmental impact statement considers effects of the HPFL under normal conditions and in the event of an accident

  9. Department of Energy Multiprogram Laboratories

    International Nuclear Information System (INIS)

    1982-09-01

    Volume III includes the following appendices: laboratory goals and missions statements; laboratory program mix; class waiver of government rights in inventions arising from the use of DOE facilities by or for third party sponsors; DOE 4300.2: research and development work performed for others; procedure for new work assignments at R and D laboratories; and DOE 5800.1: research and development laboratory technology transfer program

  10. Audio Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides an environment and facilities for auditory display research. A primary focus is the performance use of binaurally rendered 3D sound in conjunction...

  11. Performance of the participant laboratories in the National Intercomparison Program (PNI) in the period from 1991 to 2013

    International Nuclear Information System (INIS)

    Tauhata, Luiz; Vianna, Maria Elizabeth Couto Machado; Oliveira, Antonio Eduardo de; Braganca, Maura Julia Camara da Silva; Ferreira, Ana Cristina de Melo

    2015-01-01

    The statistical evaluation of the data of 23 years of the Brazilian Intercomparison Program shows the performance of the 24 Participant Laboratories of the country in the determination of 29 radionuclides in 10600 spiked samples of low level activity values. The results were shown a good performance and an evolution of the quality control for analyses of this kind of samples in this time period. (author)

  12. Exploration Laboratory Analysis FY13

    Science.gov (United States)

    Krihak, Michael; Perusek, Gail P.; Fung, Paul P.; Shaw, Tianna, L.

    2013-01-01

    The Exploration Laboratory Analysis (ELA) project supports the Exploration Medical Capability (ExMC) risk, which is stated as the Risk of Inability to Adequately Treat an Ill or Injured Crew Member, and ExMC Gap 4.05: Lack of minimally invasive in-flight laboratory capabilities with limited consumables required for diagnosing identified Exploration Medical Conditions. To mitigate this risk, the availability of inflight laboratory analysis instrumentation has been identified as an essential capability in future exploration missions. Mission architecture poses constraints on equipment and procedures that will be available to treat evidence-based medical conditions according to the Space Medicine Exploration Medical Conditions List (SMEMCL), and to perform human research studies on the International Space Station (ISS) that are supported by the Human Health and Countermeasures (HHC) element. Since there are significant similarities in the research and medical operational requirements, ELA hardware development has emerged as a joint effort between ExMC and HHC. In 2012, four significant accomplishments were achieved towards the development of exploration laboratory analysis for medical diagnostics. These achievements included (i) the development of high priority analytes for research and medical operations, (ii) the development of Level 1 functional requirements and concept of operations documentation, (iii) the selection and head-to-head competition of in-flight laboratory analysis instrumentation, and (iv) the phase one completion of the Small Business Innovation Research (SBIR) projects under the topic Smart Phone Driven Blood-Based Diagnostics. To utilize resources efficiently, the associated documentation and advanced technologies were integrated into a single ELA plan that encompasses ExMC and HHC development efforts. The requirements and high priority analytes was used in the selection of the four in-flight laboratory analysis performers. Based upon the

  13. Planetary Simulation Chambers bring Mars to laboratory studies

    Energy Technology Data Exchange (ETDEWEB)

    Mateo-Marti, E.

    2016-07-01

    Although space missions provide fundamental and unique knowledge for planetary exploration, they are always costly and extremely time-consuming. Due to the obvious technical and economical limitations of in-situ planetary exploration, laboratory simulations are among the most feasible research options for making advances in planetary exploration. Therefore, laboratory simulations of planetary environments are a necessary and complementary option to expensive space missions. Simulation chambers are economical, more versatile, and allow for a higher number of experiments than space missions. Laboratory-based facilities are able to mimic the conditions found in the atmospheres and on the surfaces of a majority of planetary objects. Number of relevant applications in Mars planetary exploration will be described in order to provide an understanding about the potential and flexibility of planetary simulation chambers systems: mainly, stability and presence of certain minerals on Mars surface; and microorganisms potential habitability under planetary environmental conditions would be studied. Therefore, simulation chambers will be a promising tools and necessary platform to design future planetary space mission and to validate in-situ measurements from orbital or rover observations. (Author)

  14. On-site laboratory support of Oak Ridge National Laboratory environmental restoration field activities

    International Nuclear Information System (INIS)

    Burn, J.L.E.

    1995-07-01

    A remedial investigation/feasibility study has been undertaken at Oak Ridge National Laboratory (ORNL). Bechtel National, Inc. and partners CH2M Hill, Ogden Environmental and Energy Services, and PEER Consultants are contracted to Lockheed Martin Energy Systems, performing this work for ORNL's Environmental Restoration (ER) Program. An on-site Close Support Laboratory (CSL) established at the ER Field Operations Facility has evolved into a laboratory where quality analytical screening results can be provided rapidly (e.g., within 24 hours of sampling). CSL capabilities include three basic areas: radiochemistry, chromatography, and wet chemistry. Radiochemical analyses include gamma spectroscopy, tritium and carbon-14 screens using liquid scintillation analysis, and gross alpha and beta counting. Cerenkov counting and crown-ether-based separation are the two rapid methods used for radiostrontium determination in water samples. By extending count times where appropriate, method detection limits can match those achieved by off-site contract laboratories. Volatile organic compounds are detected by means of gas chromatography using either headspace or purge and trap sample introduction (based on EPA 601/602). Ionic content of water samples is determined using ion chromatography and alkalinity measurement. Ion chromatography is used to quantify both anions (based on EPA 300) and cations. Wet chemistry procedures performed at the CSL include alkalinity, pH (water and soil), soil resistivity, and dissolved/suspended solids. Besides environmental samples, the CSL routinely screens health and safety and waste management samples. The cost savings of the CSL are both direct and indirect

  15. Cometabolic biotreatment of TCE-contaminated groundwater - Laboratory and bench-scale development studies

    Energy Technology Data Exchange (ETDEWEB)

    Donaldson, T L; Palumbo, A V; Boerman, P A; Jennings, H L; Lucero, A J; Tyndall, R L; Strandberg, G W; Morris, M I [Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1992-07-01

    The Oak Ridge National Laboratory is conducting a demonstration of two cometabolic technologies for biotreatment of groundwater contaminated with trichloroethylene (TCE) and other organics. Technologies based on methanotrophic (methane-utilizing) and toluene-degrading microorganisms will be compared side-by-side on the same groundwater stream. Laboratory and bench-scale bioreactor studies have been conducted to guide selection of microbial cultures and operating conditions for the field demonstration. This report presents the results of the laboratory and bench-scale studies for the methanotrophic system. (author)

  16. Applicability of the DPPH assay for evaluating the antioxidant capacity of food additives - inter-laboratory evaluation study -.

    Science.gov (United States)

    Shimamura, Tomoko; Sumikura, Yoshihiro; Yamazaki, Takeshi; Tada, Atsuko; Kashiwagi, Takehiro; Ishikawa, Hiroya; Matsui, Toshiro; Sugimoto, Naoki; Akiyama, Hiroshi; Ukeda, Hiroyuki

    2014-01-01

    An inter-laboratory evaluation study was conducted in order to evaluate the antioxidant capacity of food additives by using a 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay. Four antioxidants used as existing food additives (i.e., tea extract, grape seed extract, enju extract, and d-α-tocopherol) and 6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid (Trolox) were used as analytical samples, and 14 laboratories participated in this study. The repeatability relative standard deviation (RSD(r)) of the IC50 of Trolox, four antioxidants, and the Trolox equivalent antioxidant capacity (TEAC) were 1.8-2.2%, 2.2-2.9%, and 2.1-2.5%, respectively. Thus, the proposed DPPH assay showed good performance within the same laboratory. The reproducibility relative standard deviation (RSD(R)) of IC50 of Trolox, four antioxidants, and TEAC were 4.0-7.9%, 6.0-11%, and 3.7-9.3%, respectively. The RSD(R)/RSD(r) values of TEAC were lower than, or nearly equal to, those of IC50 of the four antioxidants, suggesting that the use of TEAC was effective for reducing the variance among the laboratories. These results showed that the proposed DPPH assay could be used as a standard method to evaluate the antioxidant capacity of food additives.

  17. Human risk relationships derived from epidemiology and laboratory studies

    International Nuclear Information System (INIS)

    Cuddihy, R.G.; Boecker, B.B.; Hahn, F.F.; McClellan, R.O.

    1983-01-01

    Proven techniques are needed for incorporating the results of laboratory toxicology studies into human risk assessments. Two sample calculations of lung cancer risk factors for inhaled radioactive particles and diesel engine exhaust are given here to illustrate a toxicology information matrix approach. This approach combines the results of epidemiology and laboratory animal studies of the substance or agent of principal concern, along with similar information on other surrogate substances. Beyond the estimates of lung cancer risk factors derived by using this approach, an additional advantage is gained by having estimates of uncertainty that can be obtained by incorporating all available toxicology information into the analysis. This approach is recommended for both risk assessment and in designing follow-on toxicology studies to improve preliminary assessments for new potentially harmful agents entering our environment

  18. Implementation of 5S Method for Ergonomic Laboratory

    Science.gov (United States)

    Dila Sari, Amarria; Ilma Rahmillah, Fety; Prabowo Aji, Bagus

    2017-06-01

    This article discusses 5S implementation in Work System Design and Ergonomic Laboratory, Department of Industrial Engineering, Islamic University of Indonesia. There are some problems related to equipment settings for activity involving students such as files which is accumulated over the previous year practicum, as well as the movement of waste in the form of time due to the placement of goods that do not fit. Therefore, this study aims to apply the 5S method in DSK & E laboratory to facilitate the work processes and reduce waste. The project is performed by laboratory management using 5S methods in response to continuous improvement (Kaizen). Moreover, some strategy and suggestions are promoted to impose 5S system within the laboratory. As a result, the tidiness and cleanliness can be achieved that lead to the great performance of laboratory users. Score assessment before implementing 5S DSKE laboratory is at 64 (2.56) while the score after implementation is 32 (1.28) and shows an improvement of 50%. This has implications for better use in the laboratory area, save time when looking for tools and materials due to its location and good visual control, as well as improving the culture and spirit of ‘5S’ on staff regarding better working environment

  19. Current practice in laboratory diagnostics of autoimmune diseases in Croatia. 
Survey of the Working group for laboratory diagnostics of autoimmune diseases of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    Science.gov (United States)

    Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana

    2016-10-15

    With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia.

  20. Laboratory studies of ion-molecule reactions and interstellar chemistry

    International Nuclear Information System (INIS)

    Koyano, Inosuke

    1989-01-01

    Several types of laboratory studies have been performed on ion-molecule reactions relevant to the formation of the interstellar molecules. Special emphasis is placed on the formation, structure, and reactivity of the C 3 H 3 + ions, which are believed to play a key role in interstellar chemistry. When these ions are produced by the reaction of C 3 H 4+ with C 3 H 4 in a beam-gas arrangement, their times-of-flight (TOF) show abnormally broad distributions regardless of the sources of the reactant C 3 H 4 + ion (photoionization of allene, propyne, the cyclopropene) and the nature of the neutral reactant, while all other product ions from the same reaction show sharp TOF distributions. On the other hand, all C 3 H 3 + ions produced by unimolecular decomposition of energetic C 3 H 4 + ions show sharp TOF distribution. The peculiarity of the C 3 H 3 + ions manifested in these and other experiments is discussed in conjunction with interstellar chemistry

  1. Factor VII assay performance: an analysis of the North American Specialized Coagulation Laboratory Association proficiency testing results.

    Science.gov (United States)

    Zantek, N D; Hsu, P; Refaai, M A; Ledford-Kraemer, M; Meijer, P; Van Cott, E M

    2013-06-01

    The performance of factor VII (FVII) assays currently used by clinical laboratories was examined in North American Specialized Coagulation Laboratory Association (NASCOLA) proficiency tests. Data from 12 surveys conducted between 2008 and 2010, involving 20 unique specimens plus four repeat-tested specimens, were analyzed. The number of laboratories per survey was 49-54 with a total of 1224 responses. Numerous reagent/instrument combinations were used. For FVII > 80 or 50 U/dL, among commonly used methods, one thromboplastin and one calibrator produced results 5-6 U/dL higher and another thromboplastin and calibrator produced results 5-6 U/dL lower than all other methods, and human thromboplastin differed from rabbit by +7.6 U/dL. Preliminary evidence suggests these differences could be due to the calibrator. For FVII <50 U/dL, differences among the commonly used reagents and calibrators were generally not significant. © 2013 Blackwell Publishing Ltd.

  2. Studies on denitrification performance of tricking filters

    International Nuclear Information System (INIS)

    Ruediger, A.

    1993-01-01

    Trickling filters are one of the oldest methods of biological waste water purification, widely used ever since they were first developed. These filters are mostly used for aerobic purification of water as highly polluted or lightly polluted reactors. While these systems are very useful for the elemination of organic pollution and the nitrification of the waste waters, denitrification of the whole plant poses considerable problems. The question is in how far trickling filters can be used as denitrification reactors. The conditions of successful denitrification in trickling filters is investigated, denitrification performance is established. Studies were conducted in laboratory, semi-industrial and industrial scale. (BBR) [de

  3. Wellness Center use at Los Alamos National Laboratory: a descriptive study

    Energy Technology Data Exchange (ETDEWEB)

    Wiggs, L.D.; Wilkinson, G.S.; Weber, C.

    1985-10-01

    This study describes employee participation during the first six months of the Los Alamos National Laboratory's corporate Wellness Program. We describe temporal patterns of use, preferred activities, frequency of use, and characteristics of employees participating in Wellness activities. Characteristics of Wellness participants are compared with characteristics of the Laboratory population. During this period the Wellness Center, a multi-use facility that houses Wellness Program activities, had 17,352 visits. Employees visiting the Wellness Center were typical of the Laboratory population in their racial and ethnic characteristics, but different in their sex and age composition. Wellness participants were younger and more likely to be female than the Laboratory population. 6 refs., 19 tabs.

  4. Developing Medicare Competitive Bidding: A Study of Clinical Laboratories

    Science.gov (United States)

    Hoerger, Thomas J.; Meadow, Ann

    1997-01-01

    Competitive bidding to derive Medicare fees promises several advantages over administered fee systems. The authors show how incentives for cost savings, quality, and access can be incorporated into bidding schemes, and they report on a study of the clinical laboratory industry conducted in preparation for a bidding demonstration. The laboratory industry is marked by variable concentration across geographic markets and, among firms themselves, by social and economic heterogeneity. The authors conclude that these conditions can be accommodated by available bidding design options and by careful selection of bidding markets. PMID:10180003

  5. Autoclaving practice in microbiology laboratories: report of a survey. The Public Health Laboratory Service Subcommittee on laboratory autoclaves.

    Science.gov (United States)

    1978-01-01

    The performance of autoclaves in 27 laboratories, operated in accordance with the normal routine of local practice, has been monitored using thermometric equipment. Sterilising performance was unsatisfactory on 10 of 62 occasions, and cooling was inadequate on 52 of 60 occasions. PMID:649767

  6. Evaluation of Radiometers Deployed at the National Renewable Energy Laboratory's Solar Radiation Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron; Wilcox, Stephen; Stoffel, Thomas

    2015-12-23

    This study analyzes the performance of various commercially available radiometers used for measuring global horizontal irradiances and direct normal irradiances. These include pyranometers, pyrheliometers, rotating shadowband radiometers, and a pyranometer with fixed internal shading and are all deployed at the National Renewable Energy Laboratory's Solar Radiation Research Laboratory. Data from 32 global horizontal irradiance and 19 direct normal irradiance radiometers are presented. The radiometers in this study were deployed for one year (from April 1, 2011, through March 31, 2012) and compared to measurements from radiometers with the lowest values of estimated measurement uncertainties for producing reference global horizontal irradiances and direct normal irradiances.

  7. Results of the Interlaboratory Exercise CSN/CIEMAT-100 Among Environmental Radioactivity Laboratories (Soil)

    International Nuclear Information System (INIS)

    Romero Gonzalez, M. L.

    2002-01-01

    The document describes the outcome of the CSN/CIEMAT-00 interlaboratory test comparison among environmental radioactivity laboratories. the exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories. the test sample was a soil containing environmental levels of K-40, Ra-226, Ac-228, Sr-90, Cs-137, Cs-134, Pu (239-240) y Am-241. the Universidad Autonoma de Barcelona prepared the material and reported adequate statistical studies of homogeneity. The results of the exercise were computed for 30 participating laboratories, and their analytical performance was assessed using the u-score approach. A raised percentage of satisfactory laboratory performance has been obtained for all the analysis, being the best performance in gamma measurements. The exercise has drawn that several laboratories have difficulties in the evaluation of combined uncertainty, mainly in analysis involving radiochemical steps. The study has shown an homogeneous inter-laboratory behaviour, and the improvement achieved through subsequent exercises in the quality of the data they are producing. (Author) 10 refs

  8. Laboratory studies of imitation/field studies of tradition: towards a synthesis in animal social learning.

    Science.gov (United States)

    Galef, Bennett G

    2015-03-01

    Here I discuss: (1) historical precedents that have resulted in comparative psychologists accepting the two-action method as the "gold standard" in laboratory investigations of imitation learning, (2) evidence suggesting that the two-action procedure may not be adequate to answer questions concerning the role of imitation in the development of traditional behaviors of animals living in natural habitat, and (3) an alternative approach to the laboratory study of imitation that might increase the relevance of laboratory studies of imitation to the work of behavioral ecologists/primatologists interested in animal traditions and their relationship to human cumulative culture. This article is part of a Special Issue entitled: Tribute to Tom Zentall. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Performance Assessment for the Idaho National Laboratory Remote-Handled Low-Level Waste Disposal Facility

    Energy Technology Data Exchange (ETDEWEB)

    Annette L. Schafer; A. Jeffrey Sondrup; Arthur S. Rood

    2012-05-01

    This performance assessment for the Remote-Handled Low-Level Radioactive Waste Disposal Facility at the Idaho National Laboratory documents the projected radiological dose impacts associated with the disposal of low-level radioactive waste at the facility. This assessment evaluates compliance with the applicable radiological criteria of the U.S. Department of Energy and the U.S. Environmental Protection Agency for protection of the public and the environment. The calculations involve modeling transport of radionuclides from buried waste to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses are calculated for both offsite receptors and individuals who inadvertently intrude into the waste after site closure. The results of the calculations are used to evaluate the future performance of the low-level radioactive waste disposal facility and to provide input for establishment of waste acceptance criteria. In addition, one-factor-at-a-time, Monte Carlo, and rank correlation analyses are included for sensitivity and uncertainty analysis. The comparison of the performance assessment results to the applicable performance objectives provides reasonable expectation that the performance objectives will be met

  10. Napping: A public health issue. From epidemiological to laboratory studies.

    Science.gov (United States)

    Faraut, Brice; Andrillon, Thomas; Vecchierini, Marie-Françoise; Leger, Damien

    2017-10-01

    Sleep specialists have proposed measures to counteract the negative short- and long-term consequences of sleep debt, and some have suggested the nap as a potential and powerful "public health tool". Here, we address this countermeasure aspect of napping viewed as an action against sleep deprivation rather than an action associated with poor health. We review the physiological functions that have been associated positively with napping in both public health and clinical settings (sleep-related accidents, work and school, and cardiovascular risk) and in laboratory-based studies with potential public health issues (cognitive performance, stress, immune function and pain sensitivity). We also discuss the circumstances in which napping-depending on several factors, including nap duration, frequency, and age-could be a potential public health tool and a countermeasure for sleep loss in terms of reducing accidents and cardiovascular events and improving sleep-restriction-sensitive working performance. However, the impact of napping and the nature of the sleep stage(s) involved still need to be evaluated, especially from the perspective of coping strategies in populations with chronic sleep debt, such as night and shift workers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. DEVELOPMENT OF BODY COMPOSITION, HORMONE PROFILE, PHYSICAL FITNESS, GENERAL PERCEPTUAL MOTOR SKILLS, SOCCER SKILLS AND ON-THE-BALL PERFORMANCE IN SOCCER-SPECIFIC LABORATORY TEST AMONG ADOLESCENT SOCCER PLAYERS

    Directory of Open Access Journals (Sweden)

    Tomi Vänttinen

    2010-12-01

    Full Text Available The aim of the present study was to examine the development of on-the-ball skills in soccer-specific laboratory test and to examine how traditional measures of body composition, hormone profile, physical fitness, general perceptual motor skills and soccer skills were related to performance measured in open skill environment among 10, 12, and 14-year-old regional male soccer players (n = 12/group. The measured variables were height, weight, fat, muscle mass, testosterone, 10m sprint, agility, counter movement jump, peripheral awareness, Eye- Hand-Foot coordination, passing skill, dribbling skill and on-the-ball skills (performance time and passing accuracy in soccer-specific laboratory test. A significant main effect by age was found in all measured variables except in fat, in peripheral awareness and in passing accuracy. In discriminant analysis 63.9% (λ = 0.603, F = 4.600, p < 0.01 of the players were classified correctly based on physical fitness and general perceptual motor skills into three ability groups originally classified with performance time in soccer-specific laboratory test. Correlation co- efficient analysis with-in age groups revealed that variables associated with performance time in soccer-specific laboratory test were peripheral awareness (r = 0.72, p < 0.01 in 10-year-olds; testosterone (r = -0.70, p < 0.05, dribbling skill (r = 0.73, p < 0.01 and passing skill (r = 0.73, p < 0.01 in 12-year-olds; agility (r = 0.79, p < 0.01, counter movement jump (r = - 0.62, p < 0.01, dribbling skill (r = 0.80, p < 0.01 and passing skill (r = 0.58, p < 0. 05 in 14-year olds. Corresponding relationships with passing accuracy were weight (r = 0.59, p < 0.05, fat (r = 0.66, p < 0.05, 10m sprint (r = 0.71, p < 0.01 and countermovement jump (r = -0.64, p < 0.05 in 10-year-olds; Eye-Hand-Foot coordination (r = 0.63, p < 0.05 in 14-year- olds. The relationship between soccer-specific anticipation time and performance time in soccer- specific

  12. Laboratory studies and model simulations of sorbent material behavior for an in-situ passive treatment barrier

    International Nuclear Information System (INIS)

    Aloysius, D.; Fuhrmann, M.

    1995-01-01

    This paper presents a study combining laboratory experiments and model simulations in support of the design and construction of a passive treatment barrier (or filter wall) for retarding the migration of Sr-90 within a water-bearing surficial sand and gravel layer. Preliminary evaluation was used to select materials for column testing. A one-dimensional finite-difference model was used to simulate the laboratory column results and extrapolation of the calibrated model was then used to assess barrier performance over extended time frames with respect to Sr-90 breakthrough and loading on the filter media. The final results of the study showed that 20 by 50 mesh clinoptilolite will attenuate Sr-90 with a maximum life expentancy of approximately 10 years. This time period is based on allowable limits of Sr-90 activity on the filter media and is also a function of site-specific conditions

  13. Availability of urinary albumin measurement in Southern Brazilian laboratories

    Directory of Open Access Journals (Sweden)

    Ariana Aguiar Soares

    2015-03-01

    Full Text Available Introduction: Diabetic kidney disease (DKD is the leading worldwide cause of end-stage renal disease. The current recommendation is to screen for DKD by evaluating estimated glomerular filtration rate (eGFR and measuring urinary albumin (UA levels in a spot sample. The aim of this study was to evaluate the availability of UA measurement in Southern Brazilian laboratories.   Methods: A cross-sectional study was conducted to assess the routine use of UA in all laboratories registered in the State Pharmacy Council ofRio Grande do Sul, the southernmost state ofBrazil. Data was collected by mail, e-mail, telephone, or personal interview. A sample size of at least 384 laboratories was necessary to achieve 5% precision at a 95% confidence level based on a fixed proportion of 0.5.   Results: Eight hundred and eighty laboratories currently registered in the state were invited to participate in the study; 548 (62% answered the technical specification questionnaire. Only 306 (55% of the 548 surveyed laboratories performed UA measurements. The laboratories were also required to provide the number of UA measurements performed per day, which ranged from less than one per week to 65 per day.  Conclusion: The availability of UA measurements is undesirably low inSouthern Brazil. This demonstrates the urgent need to increase the availability of this important test. It also reveals the gap between the current guidelines and the awareness about them among health care professionals.

  14. Argonne National Laboratory high performance network support of APS experiments

    International Nuclear Information System (INIS)

    Knot, M.J.; McMahon, R.J.

    1996-01-01

    Argonne National Laboratory is currently positioned to provide access to high performance regional and national networks. Much of the impetus for this effort is the anticipated needs of the upcoming experimental program at the APS. Some APS collaborative access teams (CATs) are already pressing for network speed improvements and security enhancements. Requirements range from the need for high data rate, secure transmission of experimental data, to the desire to establish a open-quote open-quote virtual experimental environment close-quote close-quote at their home institution. In the near future, 155 megabit/sec (Mb/s) national and regional asynchronous transfer mode (ATM) networks will be operational and available to APS users. Full-video teleconferencing, virtual presence operation of experiments, and high speed, secure transmission of data are being tested and, in some cases, will be operational. We expect these efforts to enable a substantial improvement in the speed of processing experimental results as well as an increase in convenience to the APS experimentalist. copyright 1996 American Institute of Physics

  15. Inter-Laboratory Comparison for Calibration of Relative Humidity Devices Among Accredited Laboratories in Malaysia

    Science.gov (United States)

    Hussain, F.; Khairuddin, S.; Othman, H.

    2017-01-01

    An inter-laboratory comparison in relative humidity measurements among accredited laboratories has been coordinated by the National Metrology Institute of Malaysia. It was carried out to determine the performance of the participating laboratories. The objective of the comparison was to acknowledge the participating laboratories competencies and to verify the level of accuracies declared in their scope of accreditation, in accordance with the MS ISO/IEC 17025 accreditation. The measurement parameter involved was relative humidity for the range of 30-90 %rh at a nominal temperature of 50°C. Eight accredited laboratories participated in the inter-laboratory comparison. Two units of artifacts have been circulated among the participants as the transfer standards.

  16. Safety in the Chemical Laboratory. Epidemiology of Accidents in Academic Chemistry Laboratories, Part 2. Accident Intervention Study, Legal Aspects, and Observations.

    Science.gov (United States)

    Hellmann, Margaret A.; And Others

    1986-01-01

    Reports on a chemistry laboratory accident intervention study conducted throughout the state of Colorado. Addresses the results of an initial survey of institutions of higher learning. Discusses some legal aspects concerning academic chemistry accidents. Provides some observations about academic chemistry laboratory accidents on the whole. (TW)

  17. Evaluation of Mycology Laboratory Proficiency Testing

    OpenAIRE

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient te...

  18. [Study of continuous quality improvement for clinical laboratory processes via the platform of Hospital Group].

    Science.gov (United States)

    Song, Wenqi; Shen, Ying; Peng, Xiaoxia; Tian, Jian; Wang, Hui; Xu, Lili; Nie, Xiaolu; Ni, Xin

    2015-05-26

    The program of continuous quality improvement in clinical laboratory processes for complete blood count (CBC) was launched via the platform of Beijing Children's Hospital Group in order to improve the quality of pediatric clinical laboratories. Fifteen children's hospitals of Beijing Children's Hospital group were investigated using the method of Chinese adapted continuous quality improvement with PDCA (Plan-Do-Check-Action). The questionnaire survey and inter-laboratory comparison was conducted to find the existing problems, to analyze reasons, to set forth quality targets and to put them into practice. Then, targeted training was conducted to 15 children's hospitals and the second questionnaire survey, self examinations by the clinical laboratories was performed. At the same time, the Group's online internal quality control platform was established. Overall effects of the program were evaluated so that lay a foundation for the next stage of PDCA. Both quality of control system documents and CBC internal quality control scheme for all of clinical laboratories were improved through this program. In addition, standardization of performance verification was also improved, especially with the comparable verification rate of precision and internal laboratory results up to 100%. In terms of instrument calibration and mandatory diagnostic rates, only three out of the 15 hospitals (20%) failed to pass muster in 2014 from 46.67% (seven out of the 15 hospitals) in 2013. The abnormal data of intraday precision variance coefficients of the five CBC indicator parameters (WBC, RBC, Hb, Plt and Hct) of all the 15 laboratories accounted for 1.2% (2/165) in 2014, a marked decrease from 9.6% (14/145) in 2013. While the number of the hospitals using only one horizontal quality control object for daily quality control has dropped to three from five. The 15 hospitals organized a total of 263 times of training in 2014 from 101 times in 2013, up 160%. The quality improvement program for

  19. 'Laboratory talk' in U.S. sociology, 1890-1930: the performance of scientific legitimacy.

    Science.gov (United States)

    Owens, B Robert

    2014-01-01

    This paper examines one aspect of early twentieth century debates over the meaning of scientific methodology and epistemology within the social sciences: the tendency of sociologists to invoke "laboratory" as a multivalent concept and in reference to diverse institutions and sites of exploration. The aspiration to designate or create laboratories as spaces of sociological knowledge production was broadly unifying in early American sociology (1890-1930), even though there was no general agreement about what "laboratory" meant, nor any explicit acknowledgment of that lack of consensus. The persistence of laboratory talk in sociology over decades reflects the power of "laboratory" as a productively ambiguous, legitimizing ideal for sociologists aspiring to make their discipline rigorously scientific. © 2014 Wiley Periodicals, Inc.

  20. Results of the Interlaboratory Exercise CNS/CIEMAT-05 among Environmental Radioactivity Laboratories (Vegetable Ash)

    International Nuclear Information System (INIS)

    Romero Gonzalez, M. L.; Barrera Izquierdo, M.; Valino Garcia, F.

    2006-01-01

    The document describes the outcome of the CSN/CIEMAT-05 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the IUPAC I nternational harmonised protocol for the proficiency testing of analytical chemistry laboratories . The exercise has been designed to evaluate the capability of national laboratories to determine environmental levels of radionuclides in vegetable ash samples. The sample has been prepared by the Environmental Radiation Laboratory, from the University of Barcelona, and it contains the following radionuclides: Sr-90, Pu-238, Am-241, Th-230, Pb-210, U-238, Ra-226, K-40, Ra-228, TI-208, Cs- 137 and Co-60. Reference values have been established TROUGH the kind collaboration of three international laboratories of recognized experience: IAEA MEL and IRSN-Orsay. The results of the exercise were computed for 35 participating laboratories and their analytical performance was assessed using the z-score approach. Robust statistics of the participant's results was applied to obtain the median and standard deviation, to achieve a more complete and objetiva study of the laboratories' performance. Some difficulties encountered to dissolve the test sample caused a lower response of analyses involving radiochemical separation, thus some laboratories couldn't apply their routine methods and no conclusions on PU-238, Am-241 and Th-230 performances have been obtained. The exercise has revealed an homogeneous behaviour of laboratories, being statistical parameters from the results close to the reference values. The study has shown that participant laboratories perform radioactive determinations in vegetable ash samples with satisfactory quality levels. (Author) 6 refs

  1. NVN 5694 intra laboratory validation. Feasibility study for interlaboratory- validation

    International Nuclear Information System (INIS)

    Voors, P.I.; Baard, J.H.

    1998-11-01

    Within the project NORMSTAR 2 a number of Dutch prenormative protocols have been defined for radioactivity measurements. Some of these protocols, e.g. the Dutch prenormative protocol NVN 5694, titled Methods for radiochemical determination of polonium-210 and lead-210, have not been validated, neither by intralaboratory nor interlaboratory studies. Validation studies are conducted within the framework of the programme 'Normalisatie and Validatie van Milieumethoden 1993-1997' (Standardization and Validation of test methods for environmental parameters) of the Dutch Ministry of Housing, Physical Planning and the Environment (VROM). The aims of this study were (a) a critical evaluation of the protocol, (b) investigation on the feasibility of an interlaboratory study, and (c) the interlaboratory validation of NVN 5694. The evaluation of the protocol resulted in a list of deficiencies varying from missing references to incorrect formulae. From the survey by interview it appeared that for each type of material, there are 4 to 7 laboratories willing to participate in a interlaboratory validation study. This reflects the situation in 1997. Consequently, if 4 or 6 (the minimal number) laboratories are participating and each laboratory analyses 3 subsamples, the uncertainty in the repeatability standard deviation is 49 or 40 %, respectively. If the ratio of reproducibility standard deviation to the repeatability standard deviation is equal to 1 or 2, then the uncertainty in the reproducibility standard deviation increases from 42 to 67 % and from 34 to 52 % for 4 or 6 laboratories, respectively. The intralaboratory validation was established on four different types of materials. Three types of materials (milkpowder condensate and filter) were prepared in the laboratory using the raw material and certified Pb-210 solutions, and one (sediment) was obtained from the IAEA. The ECN-prepared reference materials were used after testing on homogeneity. The pre-normative protocol can

  2. Modelling and Laboratory Studies on the Adhesion Fatigue Performance for Thin-Film Asphalt and Aggregate System

    Directory of Open Access Journals (Sweden)

    Dongsheng Wang

    2014-01-01

    Full Text Available Adhesion between asphalt and aggregate plays an important role in the performance of asphalt mixtures. A low-frequency adhesion fatigue test was proposed in this paper to study the effect of environment on the asphalt-aggregate adhesion system. The stress-based fatigue model had been utilized to describe the fatigue behavior of thin-film asphalt and aggregate system. The factors influencing the adhesion fatigue performance were also investigated. Experiment results show that asphalt has more important effect on the adhesion performance comparing with aggregate. Basalt, which is regarded as hydrophobic aggregates with low silica content, has better adhesion performance to asphalt binder when compared with granite. The effects of aging on the adhesion fatigue performance are different for PG64-22 and rubber asphalt. Long-term aging is found to reduce the adhesion fatigue lives for rubber asphalt and aggregate system, while the effect of long-term aging for aggregate and PG64-22 binder system is positive. Generally the increased stress amplitude and test temperature could induce greater damage and lead to less fatigue lives for adhesion test system.

  3. NAS Human Factors Safety Research Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory conducts an integrated program of research on the relationship of factors concerning individuals, work groups, and organizations as employees perform...

  4. Study of polyelectrolytes for Los Alamos National Laboratory. Final report

    International Nuclear Information System (INIS)

    Labonne, N.

    1994-11-01

    To assess the safety of a potential radioactive waste repository, analysis of the fluid solution containing low levels of activity need to be performed. In some cases, the radioactivity would be so weak (3--30 pCi/L) that the solution must be concentrated for measurement. For this purpose, Los Alamos National Laboratory scientists are synthesizing some water soluble polyelectrolytes, which, because they are strong complexing agents for inorganic cations, can concentrate the radioelements in solution. To assist in characterization of these polyelectrolytes, the author has performed experiments to determine physico-chemical constants, such as pKa values and stability constants. The complexation constants between both polyelectrolytes and europium were determined by two methods: solvent extraction and ion exchange. Results are presented

  5. Laboratory Performance of the Single-Sided E-A-R (registered trademark) Combat Arms Hearing Protective Earplug

    Science.gov (United States)

    2010-01-01

    Research article / Article de recherche LABORATORY PERFORMANCE OF THE SINGLE-SIDED EAR® COMBAT ARMS HEARING PROTECTIVE EARPLUG Sharon M. Abel and...external microphones for enhanced L:. -communication-? ;‘ V SOMMAIRE. Le but de cet article est de comparer 1 effet du port de bouchons conventionnels a...MA. Bekesy audiometry and loudness balance testing. In: Katz, J, editor. Handbook of clinical audiology . 3rd ed. Williams & Wilkins: Baltimore; 1985

  6. Laboratory generation of gravitational waves

    International Nuclear Information System (INIS)

    Pinto, I.M.; Rotoli, G.

    1988-01-01

    The authors have performed calculations on the basic type of gravitational wave electromagnetic laboratory generators. Their results show that laboratory generations of gravitational wave is at limit of state-of-the-art of present-day giant electromagnetic field generation

  7. Virtual Reality Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Performs basic and applied research in interactive 3D computer graphics, including visual analytics, virtual environments, and augmented reality (AR). The...

  8. Remote Laboratory in Photovoltaics

    Directory of Open Access Journals (Sweden)

    Cornel Samoila

    2009-08-01

    Full Text Available This paper presents a new concept of studying, understanding and teaching the performance of solar cells. Using NI ELVIS allows the realization of eight laboratory experiments which study all the important parameters of the solar cells. The model used for the equivalent circuit of the solar cell was the “one diode” model. For the realization of control, data acquisition and processing, a complex program was created, with a friendly interface, using the graphical programming language LabVIEW.

  9. In situ vitrification laboratory-scale test work plan

    International Nuclear Information System (INIS)

    Nagata, P.K.; Smith, N.L.

    1991-05-01

    The Buried Waste Program was established in October 1987 to accelerate the studies needed to develop a long-term management plan for the buried mixed waste at the Radioactive Waste Management Complex at Idaho Engineering Laboratory. The In Situ Vitrification Project is being conducted in a Comprehensive Environmental Response, Compensation, and Liability Act feasibility study format to identify methods for the long-term management of mixed buried waste. To support the overall feasibility study, the situ vitrification treatability investigations are proceeding along the three parallel paths: laboratory-scale tests, intermediate field tests, and field tests. Laboratory-scale tests are being performed to provide data to mathematical modeling efforts, which, in turn, will support design of the field tests and to the health and safety risk assessment. This laboratory-scale test work plan provides overall testing program direction to meet the current goals and objectives of the in situ vitrification treatability investigation. 12 refs., 1 fig., 7 tabs

  10. Measuring meaningful learning in the undergraduate chemistry laboratory

    Science.gov (United States)

    Galloway, Kelli R.

    these studies revealed students' narrow cognitive expectations for learning that go largely unmet by their experiences and diverse affective expectations and experiences. Concurrently, a qualitative study was carried out to describe and characterize students' cognitive and affective experiences in the undergraduate chemistry laboratory. Students were video recorded while performing one of their regular laboratory experiments and then interviewed about their experiences. The students' descriptions of their learning experiences were characterized by their overreliance on following the experimental procedure correctly rather than developing process-oriented problem solving skills. Future research could use the MLLI to intentionally compare different types of laboratory curricula or environments.

  11. Predicting the performance uncertainty of a 1-MW pilot-scale carbon capture system after hierarchical laboratory-scale calibration and validation

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhijie; Lai, Canhai; Marcy, Peter William; Dietiker, Jean-François; Li, Tingwen; Sarkar, Avik; Sun, Xin

    2017-05-01

    A challenging problem in designing pilot-scale carbon capture systems is to predict, with uncertainty, the adsorber performance and capture efficiency under various operating conditions where no direct experimental data exist. Motivated by this challenge, we previously proposed a hierarchical framework in which relevant parameters of physical models were sequentially calibrated from different laboratory-scale carbon capture unit (C2U) experiments. Specifically, three models of increasing complexity were identified based on the fundamental physical and chemical processes of the sorbent-based carbon capture technology. Results from the corresponding laboratory experiments were used to statistically calibrate the physical model parameters while quantifying some of their inherent uncertainty. The parameter distributions obtained from laboratory-scale C2U calibration runs are used in this study to facilitate prediction at a larger scale where no corresponding experimental results are available. In this paper, we first describe the multiphase reactive flow model for a sorbent-based 1-MW carbon capture system then analyze results from an ensemble of simulations with the upscaled model. The simulation results are used to quantify uncertainty regarding the design’s predicted efficiency in carbon capture. In particular, we determine the minimum gas flow rate necessary to achieve 90% capture efficiency with 95% confidence.

  12. Laboratory Calibration Studies in Support of ORGANICS on the International Space Station: Evolution of Organic Matter in Space

    Science.gov (United States)

    Ruiterkamp, R.; Ehrenfreund, P.; Halasinski, T.; Salama, F.; Foing, B.; Schmidt, W.

    2002-01-01

    This paper describes the scientific overview and current status of ORGANICS an exposure experiment performed on the International Space Station (ISS) to study the evolution of organic matter in space (PI: P. Ehrenfreund), with supporting laboratory experiments performed at NASA Ames. ORGANICS investigates the chemical evolution of samples submitted to long-duration exposure to space environment in near-Earth orbit. This experiment will provide information on the nature, evolution, and survival of carbon species in the interstellar medium (ISM) and in solar system targets.

  13. ENTRY 2003: The international workshop on reliable performance assessment through laboratory experiments and ground surface investigations. 10th anniversary of ENTRY

    International Nuclear Information System (INIS)

    Ishikawa, Hirohisa; Yui, Mikazu; Uchida, Masahiro; Kamei, Gento

    2004-03-01

    To commemorate the 10th anniversary of the ENTRY, a laboratory in JNC Tokai for R and D in the field of geological disposal of radioactive waste, an international workshop was held in JNC Tokai, during the term of Sept 22 to 24, 2003. A technical tour for the Horonobe Underground Research Laboratory site was also done before the workshop, on October 20 to 21, to deepen understanding the background of discussion in the workshop. The workshop contained two sessions. The topic of each session was 1. long-term transition of the near-field and 2. cooperation among the performance assessment, in-situ experiment, and laboratory experiment, respectively. In the session 1, we mainly discussed the thermal-hydrological-mechanical-chemical (THMC) coupled processes for the near-field performance assessment, especially focusing on chemical degradation effects by cement materials and the status of mechanistic understanding radionuclide migration. Silicate dissolution kinetic model, including smectite dissolution in a hyper alkaline solution, was also discussed. Then, we discussed a relevant linkage among laboratory experiments, model (simulation experiment) and database development, in-situ experiment and natural analogue. In the session 2, we discussed 1) methodology for understanding the site based on the surface and boreholes investigations, 2) identification of remained uncertainty after the surface and boreholes investigations, 3) the critical measurement at the surface and boreholes investigations, 4) feedback items from performance assessment to site characterization and 5) required data besides the site investigation. This report contains the minutes of discussion in the workshop. Presented materials were also appended with permission from the speakers. (author)

  14. Evolution of the Nuclear Safeguards Performance Laboratory PERLA on the Ispra Site of the Institute for Transuranium Elements

    International Nuclear Information System (INIS)

    Berndt, R.; Abbas, K.; Berthou, V.; De Almeida Carrapico, C.; Forcina, V.; Mayorov, V.; Mortreau, P.; Mosconi, M.; Pedersen, B.; Peerani, P.; Rosas, F.; Tagziria, H.; Tomanin, A.; Rozite, A.; Marin-Ferrer, M.; Crochemore, J.-M.; Roesgen, E.; Janssens, W.A.M.; )

    2015-01-01

    Based upon the experience of many years of operation, the safeguards Performance Laboratory PERLA will be reshaped in the near future (and relocated on the Ispra site such as not to interfere with decommissioning activities). During almost 30 years of successfully operating nuclear facilities in Ispra for supporting nuclear safeguards inspectorates with R&D, equipment development and training for in the meantime more than 1250 trainees, this laboratory is the main work-horse in this field and has functioned very frequently in the last years as easily accessible nuclear laboratory for external users. Even if a constant evolution took place in the last years, and additional facilities like the active neutron laboratory PUNITA or the ITRAP test laboratory for nuclear security R&D, testing and training have been taken in service, this step-change will allow refiguring the laboratory to face also new user expectations. NDA for safeguards continues to be a cornerstone of the measurement capacities complemented by experimental and advanced approaches, such as using active neutron interrogation, automation of measurements, complemented by Monte-Carlo simulations for neutron and gamma radiation. The tendency is also to integrate multiple plant signals (not only NDA measurements) in an overall assessment scheme and we envisage offering training and exercising capabilities for the inspectors also in this direction in the future. This paper will thus provide some insight in the concepts for the future use of the nuclear facilities on the Ispra site, which is complementary to two other contributions to this symposium, i.e., one describing the activities of our sister unit in Karlsruhe on NDA Safeguards Training and another on the new Advanced Safeguards Measurement, Monitoring and Modelling Laboratory (AS3ML) being built currently in Ispra. (author)

  15. Errors in clinical laboratories or errors in laboratory medicine?

    Science.gov (United States)

    Plebani, Mario

    2006-01-01

    Laboratory testing is a highly complex process and, although laboratory services are relatively safe, they are not as safe as they could or should be. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs dealing with analytical aspects of testing. However, a growing body of evidence accumulated in recent decades demonstrates that quality in clinical laboratories cannot be assured by merely focusing on purely analytical aspects. The more recent surveys on errors in laboratory medicine conclude that in the delivery of laboratory testing, mistakes occur more frequently before (pre-analytical) and after (post-analytical) the test has been performed. Most errors are due to pre-analytical factors (46-68.2% of total errors), while a high error rate (18.5-47% of total errors) has also been found in the post-analytical phase. Errors due to analytical problems have been significantly reduced over time, but there is evidence that, particularly for immunoassays, interference may have a serious impact on patients. A description of the most frequent and risky pre-, intra- and post-analytical errors and advice on practical steps for measuring and reducing the risk of errors is therefore given in the present paper. Many mistakes in the Total Testing Process are called "laboratory errors", although these may be due to poor communication, action taken by others involved in the testing process (e.g., physicians, nurses and phlebotomists), or poorly designed processes, all of which are beyond the laboratory's control. Likewise, there is evidence that laboratory information is only partially utilized. A recent document from the International Organization for Standardization (ISO) recommends a new, broader definition of the term "laboratory error" and a classification of errors according to different criteria. In a modern approach to total quality, centered on patients' needs and satisfaction, the risk of errors and mistakes

  16. Performance study of coal-base charcoals for removing radioiodine

    International Nuclear Information System (INIS)

    Huang Yuying; Wu Yanwei; Guo Liangtian; Jia Ming; Lu Xueshi; Zhang Hong

    1988-01-01

    In authos' laboratory sveral types of domestic coal-base charcoals are selected and impregnated and examined for their main physical and chemical performances. The results show that under the test conditions the iodine-removing efficiencies of these impregnated coal-base charcoals charcoals are not poorer than that of the impregnated fruit-shell base charcoals (such as coconut shell charcoal) and most of their physical properties can satisfy the requirements of the nuclear grade charcoals assigned in USA standards. More detailed studies will be made in the next programme

  17. Effects of physical randomness training on virtual and laboratory golf putting performance in novices.

    Science.gov (United States)

    Pataky, T C; Lamb, P F

    2018-06-01

    External randomness exists in all sports but is perhaps most obvious in golf putting where robotic putters sink only 80% of 5 m putts due to unpredictable ball-green dynamics. The purpose of this study was to test whether physical randomness training can improve putting performance in novices. A virtual random-physics golf-putting game was developed based on controlled ball-roll data. Thirty-two subjects were assigned a unique randomness gain (RG) ranging from 0.1 to 2.0-times real-world randomness. Putter face kinematics were measured in 5 m laboratory putts before and after five days of virtual training. Performance was quantified using putt success rate and "miss-adjustment correlation" (MAC), the correlation between left-right miss magnitude and subsequent right-left kinematic adjustments. Results showed no RG-success correlation (r = -0.066, p = 0.719) but mildly stronger correlations with MAC for face angle (r = -0.168, p = 0.358) and clubhead path (r = -0.302, p = 0.093). The strongest RG-MAC correlation was observed during virtual training (r = -0.692, p golf putting kinematics. Adaptation to external physical randomness during virtual training may therefore help golfers adapt to external randomness in real-world environments.

  18. Initial performance assessment of the disposal of spent nuclear fuel and high-level waste stored at Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Rechard, R.P.

    1993-12-01

    This performance assessment characterized plausible treatment options conceived by the Idaho National Engineering Laboratory (INEL) for its spent fuel and high-level radioactive waste and then modeled the performance of the resulting waste forms in two hypothetical, deep, geologic repositories: one in bedded salt and the other in granite. The results of the performance assessment are intended to help guide INEL in its study of how to prepare wastes and spent fuel for eventual permanent disposal. This assessment was part of the Waste Management Technology Development Program designed to help the US Department of Energy develop and demonstrate the capability to dispose of its nuclear waste. Although numerous caveats must be placed on the results, the general findings were as follows: Though the waste form behavior depended upon the repository type, all current and proposed waste forms provided acceptable behavior in the salt and granite repositories

  19. Exploration Laboratory Analysis

    Science.gov (United States)

    Krihak, M.; Ronzano, K.; Shaw, T.

    2016-01-01

    The Exploration Laboratory Analysis (ELA) project supports the Exploration Medical Capability (ExMC) risk to minimize or reduce the risk of adverse health outcomes and decrements in performance due to in-flight medical capabilities on human exploration missions. To mitigate this risk, the availability of inflight laboratory analysis instrumentation has been identified as an essential capability for manned exploration missions. Since a single, compact space-ready laboratory analysis capability to perform all exploration clinical measurements is not commercially available, the ELA project objective is to demonstrate the feasibility of emerging operational and analytical capability as a biomedical diagnostics precursor to long duration manned exploration missions. The initial step towards ground and flight demonstrations in fiscal year (FY) 2015 was the down selection of platform technologies for demonstrations in the space environment. The technologies selected included two Small Business Innovation Research (SBIR) performers: DNA Medicine Institutes rHEALTH X and Intelligent Optical Systems later flow assays combined with Holomics smartphone analyzer. The selection of these technologies were based on their compact size, breadth of analytical capability and favorable ability to process fluids in a space environment, among several factors. These two technologies will be advanced to meet ground and flight demonstration success criteria and requirements that will be finalized in FY16. Also, the down selected performers will continue the technology development phase towards meeting prototype deliverables in either late 2016 or 2017.

  20. CRCPD`S laboratory accrediation program

    Energy Technology Data Exchange (ETDEWEB)

    Dukes, P.M. [South Carolina Department of Health and Environmental Control, Columbia, SC (United States)

    1993-12-31

    The Conference of Radiation Control Program Directors, or CRCPD, first became involved in a calibration laboratory accreditation program about 17 years ago. Since that time, the CRCPD has formed a Committee on Ionizing Measurements which writes criteria for the accreditation of laboratories, and performs the accreditation review process. To become accredited, a laboratory must agree to an administrative review, and an onsite review, and participate in measurement quality assurance (MQA) testing with the National Institute of Standards and Technology (NIST). The CRCPD currently has four accredited laboratories. All the laboratories are working with the Conference in promoting the improvement of MQA in radiation control programs.

  1. Large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory. Summary report 2008

    International Nuclear Information System (INIS)

    Cuss, R.J.; Harrington, J.F.; Noy, D.J.

    2010-02-01

    This report describes the set-up, operation and observations from the first 1,385 days (3.8 years) of the large scale gas injection test (Lasgit) experiment conducted at the Aespoe Hard Rock Laboratory. During this time the bentonite buffer has been artificially hydrated and has given new insight into the evolution of the buffer. After 2 years (849 days) of artificial hydration a canister filter was identified to perform a series of hydraulic and gas tests, a period that lasted 268 days. The results from the gas test showed that the full-scale bentonite buffer behaved in a similar way to previous laboratory experiments. This confirms the up-scaling of laboratory observations with the addition of considerable information on the stress responses throughout the deposition hole. During the gas testing stage, the buffer was continued to artificially hydrate. Hydraulic results, from controlled and uncontrolled events, show that the buffer continues to mature and has yet to reach full maturation. Lasgit has yielded high quality data relating to the hydration of the bentonite and the evolution in hydrogeological properties adjacent to the deposition hole. The initial hydraulic and gas injection tests confirm the correct working of all control and data acquisition systems. Lasgit has been in successful operation for in excess of 1,385 days

  2. Large scale gas injection test (Lasgit) performed at the Aespoe Hard Rock Laboratory. Summary report 2008

    Energy Technology Data Exchange (ETDEWEB)

    Cuss, R.J.; Harrington, J.F.; Noy, D.J. (British Geological Survey (United Kingdom))

    2010-02-15

    This report describes the set-up, operation and observations from the first 1,385 days (3.8 years) of the large scale gas injection test (Lasgit) experiment conducted at the Aespoe Hard Rock Laboratory. During this time the bentonite buffer has been artificially hydrated and has given new insight into the evolution of the buffer. After 2 years (849 days) of artificial hydration a canister filter was identified to perform a series of hydraulic and gas tests, a period that lasted 268 days. The results from the gas test showed that the full-scale bentonite buffer behaved in a similar way to previous laboratory experiments. This confirms the up-scaling of laboratory observations with the addition of considerable information on the stress responses throughout the deposition hole. During the gas testing stage, the buffer was continued to artificially hydrate. Hydraulic results, from controlled and uncontrolled events, show that the buffer continues to mature and has yet to reach full maturation. Lasgit has yielded high quality data relating to the hydration of the bentonite and the evolution in hydrogeological properties adjacent to the deposition hole. The initial hydraulic and gas injection tests confirm the correct working of all control and data acquisition systems. Lasgit has been in successful operation for in excess of 1,385 days

  3. Students' motivation toward laboratory work in physiology teaching.

    Science.gov (United States)

    Dohn, Niels Bonderup; Fago, Angela; Overgaard, Johannes; Madsen, Peter Teglberg; Malte, Hans

    2016-09-01

    The laboratory has been given a central role in physiology education, and teachers report that it is motivating for students to undertake experimental work on live animals or measuring physiological responses on the students themselves. Since motivation is a critical variable for academic learning and achievement, then we must concern ourselves with questions that examine how students engage in laboratory work and persist at such activities. The purpose of the present study was to investigate how laboratory work influences student motivation in physiology. We administered the Lab Motivation Scale to assess our students' levels of interest, willingness to engage (effort), and confidence in understanding (self-efficacy). We also asked students about the role of laboratory work for their own learning and their experience in the physiology laboratory. Our results documented high levels of interest, effort, and self-efficacy among the students. Correlation analyses were performed on the three motivation scales and exam results, yet a significant correlation was only found between self-efficacy in laboratory work and academic performance at the final exam. However, almost all students reported that laboratory work was very important for learning difficult concepts and physiological processes (e.g., action potential), as the hands-on experiences gave a more concrete idea of the learning content and made the content easier to remember. These results have implications for classroom practice as biology students find laboratory exercises highly motivating, despite their different personal interests and subject preferences. This highlights the importance of not replacing laboratory work by other nonpractical approaches, for example, video demonstrations or computer simulations. Copyright © 2016 The American Physiological Society.

  4. Road traffic noise-induced sleep disturbances: a comparison between laboratory and field settings

    Science.gov (United States)

    Skånberg, Annbritt

    2004-10-01

    Due to the ongoing discussion about the relevance of sleep studies performed in the laboratory, the aim of this study was to assess the effects of road traffic noise exposure on sleep in laboratory and in field settings. Eighteen healthy young subjects participated in the study. They were exposed to noise from road traffic in the laboratory and exposed to the same recorded traffic noise exposure in their own homes. Their sleep was evaluated with wrist actigraphs and questionnaires on sleep. No significant increase in effects of noise on sleep in the laboratory was found. The results indicate that laboratory experiments do not exaggerate effects of noise on sleep.

  5. Laboratory Studies of the Formation of Carbonaceous Cosmic Dust from PAH Precursors

    Science.gov (United States)

    Salama, Farid; Contreras, C. S.

    2012-05-01

    The study of the formation and destruction processes of cosmic dust is essential to understand and to quantify the budget of extraterrestrial organic molecules. Although dust with all its components plays an important role in the evolution of interstellar chemistry and in the formation of organic molecules, little is known on the formation and destruction processes of carbonaceous dust. PAHs are important chemical building blocks of interstellar dust. They are detected in interplanetary dust particles and in meteoritic samples and are an important, ubiquitous component of the interstellar medium. The formation of PAHs from smaller molecules has not been extensively studied. Therefore, it is imperative that laboratory experiments be conducted to study the dynamic processes of carbon grain formation from PAH precursors. Studies of interstellar dust analogs formed from a variety of PAH and hydrocarbon precursors as well as species that include O, N, and S, have recently been performed using the COSmIC facility in our laboratory under conditions that simulate interstellar and circumstellar environments. The species formed in the pulsed discharge nozzle (PDN) plasma source are detected and characterized with high-sensitivity cavity ringdown spectroscopy coupled to a Reflectron time-of-flight mass spectrometer (ReTOF-MS), thus providing both spectroscopic and ion mass information in-situ. We report the measurements obtained in these experiments. Studies with hydrocarbon precursors show the feasibility of specific molecules to form PAHs, while studies with carbon ring systems (benzene and derivatives, PAHs) precursors provide information on pathways toward larger carbonaceous molecules. From these unique measurements, we derive information on the size and the structure of interstellar dust grain particles, the growth and the destruction processes of interstellar dust and the resulting budget of extraterrestrial organic molecules. Acknowledgements: This research is

  6. The Orchestra as a Laboratory

    DEFF Research Database (Denmark)

    Paunova, Minna; Velikova, Silviya Svejenova

    with learning in these and other organizations. Zooming in on a critical case of a performance arts’ organization–an orchestra-cum-laboratory–our study seeks to advance understanding of generative forms of organizing for individual and organizational learning and creativity. Unlike traditional orchestras...... for which performance is an end and rehearsing a means, for the orchestra-cum-laboratory rehearsing is an end in itself, satisfying musicians’ drives to learn and create. We are interested to advance understanding of why and how a creative collective operates as a learning-driven performance arts......Orchestras and other performing arts organizations exist to deliver superior performance of artistic and cultural works. While performing arts organizations often serve as analytical templates to understand collective learning, creativity, and innovation, performance is not always concerted...

  7. Paying for performance: Performance incentives increase desire for the reward object.

    Science.gov (United States)

    Hur, Julia D; Nordgren, Loran F

    2016-09-01

    The current research examines how exposure to performance incentives affects one's desire for the reward object. We hypothesized that the flexible nature of performance incentives creates an attentional fixation on the reward object (e.g., money), which leads people to become more desirous of the rewards. Results from 5 laboratory experiments and 1 large-scale field study provide support for this prediction. When performance was incentivized with monetary rewards, participants reported being more desirous of money (Study 1), put in more effort to earn additional money in an ensuing task (Study 2), and were less willing to donate money to charity (Study 4). We replicated the result with nonmonetary rewards (Study 5). We also found that performance incentives increased attention to the reward object during the task, which in part explains the observed effects (Study 6). A large-scale field study replicated these findings in a real-world setting (Study 7). One laboratory experiment failed to replicate (Study 3). (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  8. Performance Measurement, Expectancy and Agency Theory: An Experimental Study

    OpenAIRE

    Randolph Sloof; Mirjam van Praag

    2007-01-01

    Theoretical analyses of (optimal) performance measures are typically performed within the realm of the linear agency model. An important implication of this model is that, for a given compensation scheme, the agent's optimal effort choice is unrelated to the amount of noise in the performance measure. In contrast, expectancy theory as developed by psychologists predicts that effort levels are increasing in the signal-to-noise ratio. We conduct a real effort laboratory experiment to assess the...

  9. Final report of the Multiprogram Laboratory Panel Energy Research Advisory Board. Volume II. Support studies

    International Nuclear Information System (INIS)

    Spiewak, I.; Guthrie, M.P.; Nichols, J.P.; Preston, E.L.; West, C.D.; Wilbanks, T.J.; Wilkes, B.Y.; Zerby, A.C.

    1982-09-01

    Volume II - support studies for nine national laboratories include: report of statistical data on the multiprogram laboratories; examples of national laboratory use in foreign countries; domestic models for national laboratory utilization; relationships of laboratories with industry and universities; uses of laboratories for training industrial R and D personnel; legal mandates and constraints on the national laboratories; with appendices on facts about Harwell, CEN-Saclay, TNO, Studsvik, and JAERI-Tokai; the Requirements Boards of the United Kingdom Department of Industry; impact of President's FY 1983 budget; and the PNL experiment

  10. Method to Increase Undergraduate Laboratory Student Confidence in Performing Independent Research?

    OpenAIRE

    Kempton, Colton E.; Weber, K. Scott; Johnson, Steven M.

    2017-01-01

    The goal of an undergraduate laboratory course should be not only to introduce the students to biology methodologies and techniques, but also to teach them independent analytical thinking skills and proper experiment design.  This is especially true for advanced biology laboratory courses that undergraduate students typically take as a junior or senior in college.  Many courses achieve the goal of teaching techniques, but fail to approach the larger goal of teaching critical thinking, experim...

  11. Preliminary study: Formaldehyde exposure in laboratories of Sharjah university in UAE

    OpenAIRE

    Ahmed, Hafiz Omer

    2011-01-01

    Objectives : Laboratory technicians, students, and instructors are at high risk, because they deal with chemicals including formaldehyde. Thus, this preliminary study was conducted to measure the concentration of formaldehyde in the laboratories of the University of Sharjah in UAE. Materials and Methods: Thirty-two air samples were collected and analyzed for formaldehyde using National Institute for Occupational Safety and Health (NIOSH) method 3500. In this method, formaldehyde reacts with c...

  12. COLAB: A Laboratory Environment for Studying Analyst Sensemaking and Collaboration

    National Research Council Canada - National Science Library

    Morrison, Clayton T; Cohen, Paul R

    2005-01-01

    COLAB is a laboratory for studying tools that facilitate collaboration and sensemaking among groups of human analysts as they build interpretations of unfolding situations based on accruing intelligence data...

  13. Powered Flight Design and Reconstructed Performance Summary for the Mars Science Laboratory Mission

    Science.gov (United States)

    Sell, Steven; Chen, Allen; Davis, Jody; San Martin, Miguel; Serricchio, Frederick; Singh, Gurkirpal

    2013-01-01

    The Powered Flight segment of Mars Science Laboratory's (MSL) Entry, Descent, and Landing (EDL) system extends from backshell separation through landing. This segment is responsible for removing the final 0.1% of the kinetic energy dissipated during EDL and culminating with the successful touchdown of the rover on the surface of Mars. Many challenges exist in the Powered Flight segment: extraction of Powered Descent Vehicle from the backshell, performing a 300m divert maneuver to avoid the backshell and parachute, slowing the descent from 85 m/s to 0.75 m/s and successfully lowering the rover on a 7.5m bridle beneath the rocket-powered Descent Stage and gently placing it on the surface using the Sky Crane Maneuver. Finally, the nearly-spent Descent Stage must execute a Flyaway maneuver to ensure surface impact a safe distance from the Rover. This paper provides an overview of the powered flight design, key features, and event timeline. It also summarizes Curiosity's as flown performance on the night of August 5th as reconstructed by the flight team.

  14. Radiological design of hot laboratories

    International Nuclear Information System (INIS)

    Unruh, C.M.

    1976-04-01

    The fundamental design objectives for a laboratory where work with highly radioactive and highly toxic materials, such as plutonium and transplutonium nuclides, is performed are (1) to accomplish the purpose of the laboratory; (2) to protect the environment, (3) to provide safe working conditions; and (4) to keep radiation exposure to staff as low as practicable. The major planning and design features of a well engineered plutonium or transplutonium laboratory are given

  15. Radiological design of hot laboratories

    International Nuclear Information System (INIS)

    Unruh, C.M.

    1976-01-01

    The fundamental design objectives for a laboratory where work with highly radioactive and highly toxic materials, such as plutonium and transplutonium nuclides, is performed, are (1) to accomplish the purpose of the laboratory, (2) to protect the environment, (3) to provide safe working conditions, and (4) to keep radiation exposure to staff as low as practicable. The major planning and design features of well-engineered plutonium or transplutonium laboratory are given. (author)

  16. GSPEL - Calorimeter Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — Testing performance claims on heat transfer componentsThe Calorimeter Lab, located in the Ground Systems Power and Energy Lab (GSPEL), is one of the largest in the...

  17. Method for the determination of catechin and epicatechin enantiomers in cocoa-based ingredients and products by high-performance liquid chromatography: single-laboratory validation.

    Science.gov (United States)

    Machonis, Philip R; Jones, Matthew A; Schaneberg, Brian T; Kwik-Uribe, Catherine L

    2012-01-01

    A single-laboratory validation study was performed for an HPLC method to identify and quantify the flavanol enantiomers (+)- and (-)-epicatechin and (+)- and (-)-catechin in cocoa-based ingredients and products. These compounds were eluted isocratically with an ammonium acetate-methanol mobile phase applied to a modified beta-cyclodextrin chiral stationary phase and detected using fluorescence. Spike recovery experiments using appropriate matrix blanks, along with cocoa extract, cocoa powder, and dark chocolate, were used to evaluate accuracy, repeatability, specificity, LOD, LOQ, and linearity of the method as performed by a single analyst on multiple days. In all samples analyzed, (-)-epicatechin was the predominant flavanol and represented 68-91% of the total monomeric flavanols detected. For the cocoa-based products, within-day (intraday) precision for (-)-epicatechin was between 1.46-3.22%, for (+)-catechin between 3.66-6.90%, and for (-)-catechin between 1.69-6.89%; (+)-epicatechin was not detected in these samples. Recoveries for the three sample types investigated ranged from 82.2 to 102.1% at the 50% spiking level, 83.7 to 102.0% at the 100% spiking level, and 80.4 to 101.1% at the 200% spiking level. Based on performance results, this method may be suitable for routine laboratory use in analysis of cocoa-based ingredients and products.

  18. The Laboratory Diagnosis of HIV Infections

    Directory of Open Access Journals (Sweden)

    Margaret Fearon

    2005-01-01

    Full Text Available HIV diagnostic testing has come a long way since its inception in the early 1980s. Current enzyme immunoassays are sensitive enough to detect antibody as early as one to two weeks after infection. A variety of other assays are essential to confirm positive antibody screens (Western blot, polymerase chain reaction [PCR], provide an adjunct to antibody testing (p24 antigen, PCR, or provide additional information for the clinician treating HIV-positive patients (qualitative and quantitative PCR, and genotyping. Most diagnostic laboratories have complex testing algorithms to ensure accuracy of results and optimal use of laboratory resources. The choice of assays is guided by the initial screening results and the clinical information provided by the physician; both are integral to the laboratory's ability to provide an accurate laboratory diagnosis. Laboratories should also provide specific information on specimen collection, storage and transport so that specimen integrity is not compromised, thereby preserving the accuracy of laboratory results. Point of Care tests have become increasingly popular in the United States and some places in Canada over the past several years. These tests provide rapid, on-site HIV results in a format that is relatively easy for clinic staff to perform. However, the performance of these tests requires adherence to good laboratory quality control practices, as well as the backup of a licensed diagnostic laboratory to provide confirmation and resolution of positive or indeterminate results. Laboratory quality assurance programs and the participation in HIV proficiency testing programs are essential to ensure that diagnostic laboratories provide accurate, timely and clinically relevant laboratory results.

  19. Binary and multi-category ratings in a laboratory observer performance study: A comparison

    OpenAIRE

    Gur, David; Bandos, Andriy I.; King, Jill L.; Klym, Amy H.; Cohen, Cathy S.; Hakim, Christiane M.; Hardesty, Lara A.; Ganott, Marie A.; Perrin, Ronald L.; Poller, William R.; Shah, Ratan; Sumkin, Jules H.; Wallace, Luisa P.; Rockette, Howard E.

    2008-01-01

    The authors investigated radiologists, performances during retrospective interpretation of screening mammograms when using a binary decision whether to recall a woman for additional procedures or not and compared it with their receiver operating characteristic (ROC) type performance curves using a semi-continuous rating scale. Under an Institutional Review Board approved protocol nine experienced radiologists independently rated an enriched set of 155 examinations that they had not personally...

  20. Application of laboratory microtomography to the study of mineralized tissues

    International Nuclear Information System (INIS)

    Elliot, J.C.; Davis, G.R.; Anderson, P.; Wong, F.S.L.; Dowker, S.E.P.; Mercer, C.E.

    1997-01-01

    The principles of microtomography are briefly presented and recent studies of mineralized tissues using laboratory and synchrotron X-ray sources are reviewed. Results are given of investigations undertaken with laboratory systems using either a 1 st generation (single beam of 15 mu m and energy dispersive detector) or a novel 4 th generation system with 2-D detector that can provide 3-D images with vowels of 38x38x38 mu m ''3 of specimens with diameter up to 40 mm. Studies include mineral concentration distributions in cortical bone trabecular structure in a human vertebral body, cracking of bone under compression in situ and root canal obturation and Er: YAG laser application to enamel and dentine. Future applications of microtomography to the study of mineralized tissues and their interaction with biomaterials are discussed.(Author) 31 refs

  1. Guidance for laboratories performing molecular pathology for cancer patients

    NARCIS (Netherlands)

    Cree, Ian A.; Deans, Zandra; Ligtenberg, Marjolijn J. L.; Normanno, Nicola; Edsjo, Anders; Rouleau, Etienne; Sole, Francesc; Thunnissen, Erik; Timens, Wim; Schuuring, Ed; Dequeker, Elisabeth; Murray, Samuel; Dietel, Manfred; Groenen, Patricia; Van Krieken, J. Han

    2014-01-01

    Molecular testing is becoming an important part of the diagnosis of any patient with cancer. The challenge to laboratories is to meet this need, using reliable methods and processes to ensure that patients receive a timely and accurate report on which their treatment will be based. The aim of this

  2. Guidance for laboratories performing molecular pathology for cancer patients

    NARCIS (Netherlands)

    Cree, Ian A.; Deans, Zandra; Ligtenberg, Marjolijn J. L.; Normanno, Nicola; Edsjo, Anders; Rouleau, Etienne; Sole, Francesc; Thunnissen, Erik; Timens, Wim; Schuuring, Ed; Dequeker, Elisabeth; Murray, Samuel; Dietel, Manfred; Groenen, Patricia; Van Krieken, J. Han

    Molecular testing is becoming an important part of the diagnosis of any patient with cancer. The challenge to laboratories is to meet this need, using reliable methods and processes to ensure that patients receive a timely and accurate report on which their treatment will be based. The aim of this

  3. Laboratory accreditation in developing economies

    International Nuclear Information System (INIS)

    Loesener, O.

    2004-01-01

    Full text: Accreditation of laboratories has been practiced for well over one hundred years with the primary objective of seeking a formal recognition for the competence of a laboratory to perform specified tests or measurements. While first accreditation schemes intended initially to serve only the immediate needs of the body making the evaluation with the purpose of minimizing testing and inspection to be conducted by laboratories, third-party accreditation enables a laboratory to demonstrate its capability as well as availability of all necessary resources to undertake particular tests correctly and that is managed in such a way that it is likely to do this consistently, taking into consideration standards developed by national and international standards-setting bodies. The international standard ISO/IEC 17025 and laboratory accreditation are concerned with competence and quality management of laboratories only, thus requiring a single common set of criteria applicable to them. Quality assurance is therefore fully relevant to laboratories in general and analytical laboratories in particular; it should not be confused with the certification approach according to ISO/IEC 9000 family of standards, that is concerned with quality management applicable to any organization as a whole. The role of laboratory accreditation can be manifold, but in all cases the recipient of the test report needs to have confidence that the data in it is reliable, particularly if the test data is important in a decision-making process. As such, it offers a comprehensive way to ensure: - the availability of managerial and technical staff with the authority and resources needed; - the effectiveness of equipment management, traceability of measurement and safety procedures; - the performance of tests, taking into consideration laboratory accommodation and facilities as well as laboratory practices. The presentation will include also some practical aspects of quality management system

  4. [View of a Laboratory Physician on the Present and Future of Clinical Laboratories].

    Science.gov (United States)

    Matsuo, Shuji

    2014-10-01

    It is meaningful to discuss the "present and future of laboratories" for the development of laboratories and education of medical technologists. Laboratory staff must be able to perform urgent high-quality tests and take part in so-called team-based medicine and should be proud of devising systems that efficiently provide laboratory data for all medical staff. On the other hand, there may be staff with a poor sense of professionalism who work no more than is expected and too readily ask firms and commercial laboratories to solve problems. Overwork caused by providing team-based medicine and a decrease in numbers of clinical chemists are concerns. The following are hoped for in the future. Firstly, laboratory staff will become conscious of their own high-level abilities and expand their areas of work, for example, bioscience, proteomics, and reproductive medicine. Secondly, a consultation system for medical staff and patients will be established. Thirdly, clinical research will be advanced, such as investigating unknown pathophysiologies using laboratory data and samples, and developing new methods of measurement. Lastly, it is of overriding importance that staff of laboratory and educational facilities will cooperate with each other to train the next generation. In conclusion, each laboratory should be appreciated, attractive, positive regarding its contribution to society, and show individuality.

  5. Laboratory assessment of oxidative stress in semen

    Directory of Open Access Journals (Sweden)

    Ashok Agarwal

    2018-03-01

    Full Text Available Objectives: To evaluate different laboratory assessments of oxidative stress (OS in semen and identify a cost-efficient and highly sensitive instrument capable of providing a comprehensive measure of OS in a clinical setting, as early intervention and an accurate diagnostic test are important because they help maintain a balance of free radicals and antioxidants; otherwise, excessive OS could lead to sperm damage and result in male infertility. Materials and methods: A systematic literature search was performed through a MedLine database search using the keywords ‘semen’ AND ‘oxygen reduction potential’. We also reviewed the references of retrieved articles to search for other potentially relevant research articles and additional book chapters discussing laboratory assessments for OS, ranging from 1994 to 2017. A total of 29 articles and book chapters involving OS-related laboratory assays were included. We excluded animal studies and articles written in languages other than English. Results: Direct laboratory techniques include: chemiluminescence, nitro blue tetrazolium, cytochrome C reduction test, fluorescein probe, electron spin resonance and oxidation–reduction potential (ORP. Indirect laboratory techniques include: measurement of Endtz test, lipid peroxidation, chemokines, antioxidants/micronutrients/vitamins, ascorbate, total antioxidant capacity, or DNA damage. Each of these laboratory techniques has its advantages and disadvantages. Conclusion: Traditional OS laboratory assessments have their limitations. Amongst the prevalent laboratory techniques, ORP is novel and better option as it can be easily used in a clinical setting to provide a comprehensive review of OS. However, more studies are needed to evaluate its reproducibility across various laboratory centres. Keywords: Semen, male infertility, Oxidative stress, Chemiluminescence, Total antioxidant capacity, Oxidation-reduction potential

  6. Setting analytical performance specifications based on outcome studies - is it possible?

    NARCIS (Netherlands)

    Horvath, Andrea Rita; Bossuyt, Patrick M. M.; Sandberg, Sverre; John, Andrew St; Monaghan, Phillip J.; Verhagen-Kamerbeek, Wilma D. J.; Lennartz, Lieselotte; Cobbaert, Christa M.; Ebert, Christoph; Lord, Sarah J.

    2015-01-01

    The 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine proposed a simplified hierarchy for setting analytical performance specifications (APS). The top two levels of the 1999 Stockholm hierarchy, i.e., evaluation of the effect of analytical performance

  7. Laboratory studies of radionuclide transport in fractured Climax granite

    International Nuclear Information System (INIS)

    Failor, R.; Isherwood, D.; Raber, E.; Vandergraaf, T.

    1982-06-01

    This report documents our laboratory studies of radionuclide transport in fractured granite cores. To simulate natural conditions, our laboratory studies used naturally fractured cores and natural ground water from the Climax Granite Stock at the Nevada Test Site. For comparison, additional tests used artificially fractured granite cores or distilled water. Relative to the flow of tritiated water, 85 Sr and /sup 95m/Tc showed little or no retardation, whereas 137 Cs was retarded. After the transport runs the cores retained varying amounts of the injected radionuclides along the fracture. Autoradiography revealed some correlation between sorption and the fracture fill material. Strontium and cesium retention increased when the change was made from natural ground water to distilled water. Artificial fractures retained less 137 Cs than most natural fractures. Estimated fracture apertures from 18 to 60 μm and hydraulic conductivities from 1.7 to 26 x 10 -3 m/s were calculated from the core measurements

  8. Research study on the effects of illumination on performance of control room tasks

    International Nuclear Information System (INIS)

    Silverman, E.B.; Horst, R.L.; Parris, H.L.; O'Brien, J.

    1990-01-01

    The illumination in the control rooms of many operating nuclear plants falls below the levels specified in the NUREG-0700 guidelines. However, these guidelines are based on human perception and performance data which were acquired under laboratory conditions and with tasks very different from those typically found in control rooms. The objective of the present studies was to gather empirical data regarding the levels of illumination sufficient for performing tasks analogous to those performed in control rooms. Several tasks were designed to engage the perceptual and cognitive processes that are representative of actual control room performance. In a computerized laboratory test-bed, subjects scanned edgewise meters, examined hard-copy X-Y plots to discern the value of the displayed function at specific coordinates, and proofread hard-copy plant procedures. In a power plant control room simulator, data were likewise collected in a meter reading task and similar tasks representing elements of specific job-performance measures. For each task, response time and accuracy were measured under a range of illumination levels. Subjective comfort ratings were also obtained for each illumination level. The results from both settings indicated that with decreasing illumination, increased errors and/or longer response times occurred only for levels below ten footcandles, if at all. These data suggest that adequate performance in control room tasks can be achieved at illumination levels below those recommended in NUREG-0700

  9. Dynamic surface deformation of silicone elastomers for management of marine biofouling: laboratory and field studies using pneumatic actuation.

    Science.gov (United States)

    Shivapooja, Phanindhar; Wang, Qiming; Szott, Lizzy M; Orihuela, Beatriz; Rittschof, Daniel; Zhao, Xuanhe; López, Gabriel P

    2015-01-01

    Many strategies have been developed to improve the fouling release (FR) performance of silicone coatings. However, biofilms inevitably build on these surfaces over time. Previous studies have shown that intentional deformation of silicone elastomers can be employed to detach biofouling species. In this study, inspired by the methods used in soft-robotic systems, controlled deformation of silicone elastomers via pneumatic actuation was employed to detach adherent biofilms. Using programmed surface deformation, it was possible to release > 90% of biofilm from surfaces in both laboratory and field environments. A higher substratum strain was required to remove biofilms accumulated in the field environment as compared with laboratory-grown biofilms. Further, the study indicated that substratum modulus influences the strain needed to de-bond biofilms. Surface deformation-based approaches have potential for use in the management of biofouling in a number of technological areas, including in niche applications where pneumatic actuation of surface deformation is feasible.

  10. An integrated performance measure for environmental restoration at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Boston, H.L.; Kuhaida, A.J. Jr.; Garland, S.B.

    1992-01-01

    A number of contaminated sites at the Oak Ridge National Laboratory (ORNL) require remediation. A strategy has been developed to support the remediation of individual sites, while providing an integrated measure of contaminant release from all sites and serving as a performance measure for remedial efforts. Most ORNL facilities are in one watershed and groundwater pathways are known to be localized within the watershed. Thus the stream system is the receptor for contaminants released from individual sites and a conduit for contaminant transport off site. Monitoring at key locations in the watershed is linked with information from environmental investigations to: (1) identify and quantify contaminant fluxes; (2) identify the pathways of greatest concern for human health and ecological risk; (3) improve conceptual models of contaminant movement; (4) evaluate remedial alternatives; (5) prioritize sites for remediation; and, (6) document reduced contaminant fluxes following remediation. The contaminants of greatest concern are associated with soil and aquatic sediment. The subjects of investigations range from soil processes and bioindicators of contaminant exposure, to phenomena at the watershed-level such as models predicting contaminant movement during large storms and predicting groundwater transport of contaminants. These efforts provide the foundation needed to coordinate the remediation of individual sites and to assess the overall performance of remedial actions

  11. ORIGINAL ARTICLES Assessment of routine laboratory screening of ...

    African Journals Online (AJOL)

    clinical examination rather than failing to perform blanket laboratory and radiological ... additional information to that obtained from a thorough history and clinical ... reviewed to determine the patient's diagnosis and management plan. ... system were considered not to have had laboratory investigations performed.

  12. Annual report of Laboratory of Nuclear Studies, Osaka University, 1980

    International Nuclear Information System (INIS)

    1981-01-01

    This is the progress report of the research activities in the Laboratory of Nuclear Studies during the period from April, 1980, to March, 1981. The activities were carried out by the OULNS staffs and also by outsiders at the OULNS. In this period, the X-ray astrophysics group, the radiation physics group and the high energy physics group joined the OULNS. The main accelerators in the OULNS are a 110 cm variable energy cyclotron and a 4.7 MeV Van de Graaff machine. The detailed experimental studies on inbeam e-gamma spectroscopy and beta-decay were carried out at two accelerator laboratories. The radiochemistry facility and a mass spectrometer were fully used. The research activities extended to high energy physics by utilizing national facilities, such as a 230 cm cyclotron in the Research Center for Nuclear Physics and a proton synchrotron in the National Laboratory for High Energy Physics. The theoretical studies on elementary particles and nuclear physics were carried out also. It is important that the facilities in the OULNS were used by the outsiders in Osaka University, such as solid state physics group and particle-induced X-ray group. The activities of the divisions of cyclotron, Van de Graaff, high energy physics, accelerator development and nuclear instrumentation, mass spectroscopy, radioisotope, solid state and theoretical physics are reported. (Kako, I.)

  13. Linear Accelerator Laboratory

    International Nuclear Information System (INIS)

    1976-01-01

    This report covers the activity of the Linear Accelerator Laboratory during the period June 1974-June 1976. The activity of the Laboratory is essentially centered on high energy physics. The main activities were: experiments performed with the colliding rings (ACO), construction of the new colliding rings and beginning of the work at higher energy (DCI), bubble chamber experiments with the CERN PS neutrino beam, counter experiments with CERN's PS and setting-up of equipment for new experiments with CERN's SPS. During this period a project has also been prepared for an experiment with the new PETRA colliding ring at Hamburg. On the other hand, intense collaboration with the LURE Laboratory, using the electron synchrotron radiation emitted by ACO and DCI, has been developed [fr

  14. Ergonomic assessments of three Idaho National Engineering Laboratory cafeterias

    Energy Technology Data Exchange (ETDEWEB)

    Ostrom, L.T.; Romero, H.A.; Gilbert, B.G.; Wilhelmsen, C.A.

    1993-01-01

    The Idaho National Engineering Laboratory is a Department of Energy facility that performs a variety of engineering and research projects. EG G Idaho is the prime contractor for the laboratory and, as such, performs the support functions in addition to technical, research, and development functions. As a part of the EG G Idaho Industrial Hygiene Initiative, ergonomic assessments were conducted at three Idaho National Engineering Laboratory Cafeterias. The purposes of the assessments were to determine whether ergonomic problems existed in the work places and, if so, to make recommendations to improve the work place and task designs. The study showed there were ergonomic problems in all three cafeterias assessed. The primary ergonomic stresses observed included wrist and shoulder stress in the dish washing task, postural stress in the dish washing and food preparation tasks, and back stress in the food handling tasks.

  15. Ergonomic assessments of three Idaho National Engineering Laboratory cafeterias

    Energy Technology Data Exchange (ETDEWEB)

    Ostrom, L.T.; Romero, H.A.; Gilbert, B.G.; Wilhelmsen, C.A.

    1993-05-01

    The Idaho National Engineering Laboratory is a Department of Energy facility that performs a variety of engineering and research projects. EG&G Idaho is the prime contractor for the laboratory and, as such, performs the support functions in addition to technical, research, and development functions. As a part of the EG&G Idaho Industrial Hygiene Initiative, ergonomic assessments were conducted at three Idaho National Engineering Laboratory Cafeterias. The purposes of the assessments were to determine whether ergonomic problems existed in the work places and, if so, to make recommendations to improve the work place and task designs. The study showed there were ergonomic problems in all three cafeterias assessed. The primary ergonomic stresses observed included wrist and shoulder stress in the dish washing task, postural stress in the dish washing and food preparation tasks, and back stress in the food handling tasks.

  16. Draft Strategic Laboratory Missions Plan. Volume II

    International Nuclear Information System (INIS)

    1996-03-01

    This volume described in detail the Department's research and technology development activities and their funding at the Department's laboratories. It includes 166 Mission Activity Profiles, organized by major mission area, with each representing a discrete budget function called a Budget and Reporting (B ampersand R) Code. The activities profiled here encompass the total research and technology development funding of the laboratories from the Department. Each profile includes a description of the activity and shows how the funding for that activity is distributed among the DOE laboratories as well as universities and industry. The profiles also indicate the principal laboratories for each activity, as well as which other laboratories are involved. The information in this volume is at the core of the Strategic Laboratory Mission Plan. It enables a reader to follow funds from the Department's appropriation to a specific activity description and to specific R ampersand D performing institutions. This information will enable the Department, along with the Laboratory Operations Board and Congress, to review the distribution of R ampersand D performers chosen to execute the Department's missions

  17. Draft Strategic Laboratory Missions Plan. Volume II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    This volume described in detail the Department`s research and technology development activities and their funding at the Department`s laboratories. It includes 166 Mission Activity Profiles, organized by major mission area, with each representing a discrete budget function called a Budget and Reporting (B & R) Code. The activities profiled here encompass the total research and technology development funding of the laboratories from the Department. Each profile includes a description of the activity and shows how the funding for that activity is distributed among the DOE laboratories as well as universities and industry. The profiles also indicate the principal laboratories for each activity, as well as which other laboratories are involved. The information in this volume is at the core of the Strategic Laboratory Mission Plan. It enables a reader to follow funds from the Department`s appropriation to a specific activity description and to specific R & D performing institutions. This information will enable the Department, along with the Laboratory Operations Board and Congress, to review the distribution of R & D performers chosen to execute the Department`s missions.

  18. Impact of laboratory accreditation on patient care and the health system.

    Science.gov (United States)

    Peter, Trevor F; Rotz, Philip D; Blair, Duncan H; Khine, Aye-Aye; Freeman, Richard R; Murtagh, Maurine M

    2010-10-01

    Accreditation is emerging as a preferred framework for building quality medical laboratory systems in resource-limited settings. Despite the low numbers of laboratories accredited to date, accreditation has the potential to improve the quality of health care for patients through the reduction of testing errors and attendant decreases in inappropriate treatment. Accredited laboratories can become more accountable and less dependent on external support. Efforts made to achieve accreditation may also lead to improvements in the management of laboratory networks by focusing attention on areas of greatest need and accelerating improvement in areas such as supply chain, training, and instrument maintenance. Laboratory accreditation may also have a positive influence on performance in other areas of health care systems by allowing laboratories to demonstrate high standards of service delivery. Accreditation may, thus, provide an effective mechanism for health system improvement yielding long-term benefits in the quality, cost-effectiveness, and sustainability of public health programs. Further studies are needed to strengthen the evidence on the benefits of accreditation and to justify the resources needed to implement accreditation programs aimed at improving the performance of laboratory systems.

  19. The quality of veterinary in-clinic and reference laboratory biochemical testing.

    Science.gov (United States)

    Rishniw, Mark; Pion, Paul D; Maher, Tammy

    2012-03-01

    Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.

  20. Laboratory course on silicon sensors

    CERN Document Server

    Crescio, E; Roe, S; Rudge, A

    2003-01-01

    The laboratory course consisted of four different mini sessions, in order to give the student some hands-on experience on various aspects of silicon sensors and related integrated electronics. The four experiments were. 1. Characterisation of silicon diodes for particle detection 2. Study of noise performance of the Viking readout circuit 3. Study of the position resolution of a silicon microstrip sensor 4. Study of charge transport in silicon with a fast amplifier The data in the following were obtained during the ICFA school by the students.

  1. Quality in laboratory medicine: 50years on.

    Science.gov (United States)

    Plebani, Mario

    2017-02-01

    The last 50years have seen substantial changes in the landscape of laboratory medicine: its role in modern medicine is in evolution and the quality of laboratory services is changing. The need to control and improve quality in clinical laboratories has grown hand in hand with the growth in technological developments leading to an impressive reduction of analytical errors over time. An essential cause of this impressive improvement has been the introduction and monitoring of quality indicators (QIs) such as the analytical performance specifications (in particular bias and imprecision) based on well-established goals. The evolving landscape of quality and errors in clinical laboratories moved first from analytical errors to all errors performed within the laboratory walls, subsequently to errors in laboratory medicine (including errors in test requesting and result interpretation), and finally, to a focus on errors more frequently associated with adverse events (laboratory-associated errors). After decades in which clinical laboratories have focused on monitoring and improving internal indicators of analytical quality, efficiency and productivity, it is time to shift toward indicators of total quality, clinical effectiveness and patient outcomes. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Laboratory Studies on Surface Sampling of Bacillus anthracis Contamination: Summary, Gaps, and Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Hu, Rebecca

    2011-11-28

    This report summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the (1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and (2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed and recommendations are given for future studies.

  3. Worldwide Laboratory Comparison on the Determination of Trace Elements in IAEA-452 Biota Sample

    International Nuclear Information System (INIS)

    2012-01-01

    The Marine Environmental Studies Laboratory (MESL) of the International Atomic Energy Agency's Environment Laboratories (IAEA-NAEL) has the programmatic responsibility to provide assistance to Member States' laboratories in maintaining and improving the reliability of analytical measurement results, both in trace elements and organic pollutants. This is accomplished through the provision of reference materials of marine origin, validated analytical procedures, training in the implementation of internal quality control, and through the evaluation of measurement performance by the organization of worldwide and regional interlaboratory comparison exercises. For nearly thirty years, the MESL has conducted worldwide laboratory performance studies, also known as interlaboratory comparison. The results have been used to evaluate laboratory performance with respect to a wide range of organic and inorganic pollutants, including methyl mercury. This work has been conducted in collaboration with the UNEP Regional Seas Programme. The goal of interlaboratory comparison is to demonstrate the measurement capabilities of laboratories participating in interlaboratory comparisons (ILCs) and proficiency tests (PTs). The results from ILCs or PTs are of crucial interest for laboratories as these provide clear information of its measurement capabilities. It should be pointed out that the participation is either voluntary or forced by external requirements (e.g. legal, accreditation, control bodies). NAEL's interlaboratory comparison (ILC) and proficiency test (PT) schemes involve comparison of participant's results with an assigned value, which usually is delivered as a consensus value from the overall population of test results. Those exercises are designed to monitor and demonstrate the performance and analytical capabilities of the participating laboratories, and to identify gaps and problem areas where further development is needed. Continued membership has benefits in training and

  4. Laboratory Studies of X-ray Spectra Formed by Charge Exchange

    Science.gov (United States)

    Beiersdorfer, Peter; Ali, R.; Brown, G. V.; Koutroumpa, D.; Kelley, R. L.; Kilbourne, C.; Leutenegger, M. A.; Porter, F.

    2013-04-01

    Charge exchange between ions and neutral atoms or molecules has been accepted at an important soft producing process in our solar system. By extension, charge exchange may contribute to the X-ray emission of circumstellar material. It may also produce X-ray emission at the boundaries of supernova ejecta and star burst galaxies, or whenever hot plasma collides with neutral matter. X-ray spectra of K-shell and L-shell ions formed by charge exchange have now been studied in a variety of laboratory settings. These experiments have shown several characteristic features of line formation by charge exchange when compared to the X-ray emission produced by electron-impact excitation, e.g., enhancement emission of forbidden lines and of lines from levels with high principal quantum number. They have also shown a dependence on the interaction gas and on the energy of the ion-neutral collision. Moreover, the transfer of multiple electrons is typically preferred, provided the donor molecules or atoms have multiple valence-shell electrons. The laboratory measurements are in qualitative agreement with theory. However, the details of the observed X-ray spectra, especially those recorded with high spectral resolution, can differ substantially from predictions, especially for spectra produced at collision velocities equal to or lower than those found in thermal plasmas or produced with neutral gases other than atomic hydrogen. Puzzling discrepancies can be noted, such as enhanced emission from an upper level with the 'wrong' principal quantum number. Even more puzzling is a recent experiment in which two, co-mixed bare ion species of similar atomic number produce very different Lyman series emission upon charge exchange with a given neutral gas, defying both theoretical predictions and empirical scaling. Laboratory measurements have also shown that some of the characteristic features of charge exchange can be reproduced by radiative electron capture, i.e., by capture of a continuum

  5. An analysis of laboratory activities found in "Applications In Biology/Chemistry: A Contextual Approach to Laboratory Science"

    Science.gov (United States)

    Haskins, Sandra Sue

    The purpose of this study was to quantitatively determine whether the material found in ABC promotes scientific inquiry through the inclusion of science process skills, and to quantitatively determine the type (experimental, comparative, or descriptive) and character (wet-lab, paper and pencil, model, or computer) of laboratory activities. The research design allowed for an examination of the frequency and type of science process skills required of students in 79 laboratory activities sampled from all 12 units utilizing a modified 33-item laboratory analysis inventory (LAI) (Germane et al, 1996). Interrater reliability for the science process skills was completed on 19 of the laboratory activities with a mean score of 86.1%. Interrater reliability for the type and character of the laboratory, on the same 19 laboratory activities, was completed with mean scores of 79.0% and 96.5%, respectively. It was found that all laboratory activities provide a prelaboratory activity. In addition, the science process skill category of student performance is required most often of students with the skill of learning techniques or manipulating apparatus occurring 99% of the time. The science process skill category observed the least was student planning and design, occurring only 3% of the time. Students were rarely given the opportunity to practice science process skills such as developing and testing hypotheses through experiments they have designed. Chi-square tests, applied at the .05 level of significance, revealed that there was a significant difference in the type of laboratory activities; comparative laboratory activities appeared more often (59%). In addition the character of laboratory activities, "wet-lab" activities appeared more often (90%) than any of the others.

  6. Development of a modified vermireactor for efficient vermicomposting: a laboratory study.

    Science.gov (United States)

    Jain, K; Singh, J; Gupta, S K

    2003-12-01

    Waste has become an index of growth. Utilization of waste materials for productivity purposes is important for both economic and environmental reasons. Vermicomposting is an important aspect as it converts waste to wealth. In this context, a modified vermireactor in place of the conventional vermireactor for efficient vermicomposting has been developed. In the conventional low- and high-rate vermireactors, the space for vermicomposting is reduced due to the thick layer of vermibed at the bottom of the reactor, thus a small amount of worm casts is produced. In the modified vermireactors there was only a thick moist cloth at the bottom in place of the thick vermibed which allowed a comparatively large quantity of organic waste to be vermicomposted as compared to conventional vermireactors. Laboratory studies showed that the modified vermireactor performed better than the conventional vermireactor in average vermicast produced and mg castings l(-1) (digester volume) day(-1). The study further showed that only the volume of the vermireactor was responsible for the high yield of worm casts.

  7. Laboratory Experiments on Low-crested Breakwaters

    DEFF Research Database (Denmark)

    Kramer, Morten; Zanuttigh, B.; van der Meer, J.W.

    2005-01-01

    New unique laboratory experiments on low-crested structures (LCSs) have been performed within the DELOS project. The experiments were carried out in three European laboratories aiming at extending and completing existing available information with respect to a wide range of engineering design...... in a wave channel at small scale, and scale effects regarding wave transmission and reflection were studied in a wave channel at a large scale facility. The paper describes the experiments and associated databank with respect to objectives, test program, set-ups and measurements. Results, guidelines...... and recommendations elaborated from the tests are included in the other companion papers of the Coastal Engineering Special Issue on DELOS....

  8. Laboratory modeling, field study, and numerical simulation of bioremediation of petroleum contaminants

    International Nuclear Information System (INIS)

    Livingston, R.J.; Islam, M.R.

    1999-01-01

    Historical methods of cleaning up petroleum hydrocarbons from the vadose zone, the capillary zone, and the aquifers are not technically true cleanup technologies but rather transfer techniques. In addition, environmental engineers are realizing that the standard remediation techniques are not entirely effective in removing the hazardous material in a reasonable time frame. Long-chain hydrocarbons such as kerosene, diesel, and waste oil are particularly difficult to remediate using conventional techniques. The use of bioremediation as an alternative remediation technology is fast becoming the technique of choice among many environmental professionals. This method offers substantial benefits not found in other remediation processes. Bioremediation is very cost effective, nondestructive, relatively uncomplicated in implementing, requires non specialized equipment, and can be extremely effective in removing recalcitrant petroleum hydrocarbons. This study researched the availability of viable microbial populations in the arid climate in South Dakota. Exponential growth of the bacteria and the ability of bacteria to degrade long-chain hydrocarbons indicated that healthy populations do exist and could be used to mineralize organic hydrocarbons. Experimental results indicated that bioremediation can be effectively enhanced in landfills as well as in the subsurface using a supply of harmless nutrients. The biodegradation rate can be further enhanced with the use of edible surfactant that helped disperse the petroleum products. Also, the use of hydrogen peroxide enhanced the oxygen availability and increased the degradation rate. Interestingly, the bacterial growth rate is found to be high in difficult-to-biodegrade contaminants, such as waste oil. A numerical simulation program was also developed that describes the bacterial growth in the subsurface along with the reduction in substrate (contamination). Results from this program were found to be consistent with laboratory

  9. Laboratory studies of radionuclide migration in tuff

    International Nuclear Information System (INIS)

    Rundberg, R.S.; Mitchell, A.J.; Ott, M.A.; Thompson, J.L.; Triay, I.R.

    1989-01-01

    The movement of selected radionuclides has been observed in crushed tuff, intact tuff, and fractured tuff columns. Retardation factors and dispersivities were determined from the elution profiles. Retardation factors have been compared with those predicted on the basis of batch sorption studies. This comparison forms a basis for either validating distribution coefficients or providing evidence of speciation, including colloid formation. Dispersivities measured as a function of velocity provide a means of determining the effect of sorption kinetics or mass transfer on radionuclide migration. Dispersion is also being studied in the context of scaling symmetry to develop a basis for extrapolating from the laboratory scale to the field. 21 refs., 6 figs., 2 tabs

  10. Laboratory quality improvement in Thailand's northernmost provinces.

    Science.gov (United States)

    Kanitvittaya, S; Suksai, U; Suksripanich, O; Pobkeeree, V

    2010-01-01

    In Thailand nearly 1000 public health laboratories serve 65 million people. A qualified indicator of a good quality laboratory is Thailand Medical Technology Council certification. Consequently, Chiang Rai Regional Medical Sciences Center established a development program for laboratory certification for 29 laboratories in the province. This paper seeks to examine this issue. The goal was to improve laboratory service quality by voluntary participation, peer review, training and compliance with standards. The program consisted of specific activities. Training and workshops to update laboratory staffs' quality management knowledge were organized. Staff in each laboratory performed a self-assessment using a standard check-list to evaluate ten laboratory management areas. Chiang Rai Regional Medical Sciences Center staff supported the distribution of quality materials and documents. They provided calibration services for laboratory equipment. Peer groups performed an internal audit and successful laboratories received Thailand Medical Technology Council certification. By December 2007, eight of the 29 laboratories had improved quality sufficiently to be certified. Factors that influenced laboratories' readiness for quality improvement included the number of staff, their knowledge, budget and staff commitment to the process. Moreover, the support of each hospital's laboratory working group or network was essential for success. There was no clear policy for supporting the program. Laboratories voluntarily conducted quality management using existing resources. A bottom-up approach to this kind of project can be difficult to accomplish. Laboratory professionals can work together to illustrate and highlight outcomes for top-level health officials. A top-down, practical approach would be much less difficult to implement. Quality certification is a critical step for laboratory staff, which also encourages them to aspire to international quality standards like ISO. The

  11. Customer satisfaction in anatomic pathology. A College of American Pathologists Q-Probes study of 3065 physician surveys from 94 laboratories.

    Science.gov (United States)

    Zarbo, Richard J; Nakhleh, Raouf E; Walsh, Molly

    2003-01-01

    Measurement of physicians' and patients' satisfaction with laboratory services has recently become a requirement of health care accreditation agencies in the United States. To our knowledge, this is the first customer satisfaction survey of anatomic pathology services to provide a standardized tool and benchmarks for subsequent measures of satisfaction. This Q-Probes study assessed physician satisfaction with anatomic pathology laboratory services and sought to determine characteristics that correlate with a high level of physician satisfaction. In January 2001, each laboratory used standardized survey forms to assess physician customer satisfaction with 10 specific elements of service in anatomic pathology and an overall satisfaction rating based on a scale of rankings from a 5 for excellent to a 1 for poor. Data from up to 50 surveys returned per laboratory were compiled and analyzed by the College of American Pathologists. A general questionnaire collected information about types of services offered and each laboratory's quality assurance initiatives to determine characteristics that correlate with a high level of physician satisfaction. Hospital-based laboratories in the United States (95.8%), as well as others from Canada and Australia. Ninety-four voluntary subscriber laboratories in the College of American Pathologists Q-Probes quality improvement program participated in this survey. Roughly 70% of respondents were from hospitals with occupied bedsizes of 300 or less, 65% were private nonprofit institutions, just over half were located in cities, one third were teaching hospitals, and 19% had pathology residency training programs. Overall physician satisfaction with anatomic pathology and 10 selected aspects of the laboratory service (professional interaction, diagnostic accuracy, pathologist responsiveness to problems, pathologist accessibility for frozen section, tumor board presentations, courtesy of secretarial and technical staff, communication of

  12. Planning an Automatic Fire Detection, Alarm, and Extinguishing System for Research Laboratories

    Directory of Open Access Journals (Sweden)

    Rostam Golmohamadi

    2014-04-01

    Full Text Available Background & Objectives: Educational and research laboratories in universities have a high risk of fire, because they have a variety of materials and equipment. The aim of this study was to provide a technical plan for safety improvement in educational and research laboratories of a university based on the design of automatic detection, alarm, and extinguishing systems . Methods : In this study, fire risk assessment was performed based on the standard of Military Risk Assessment method (MIL-STD-882. For all laboratories, detection and fire alarm systems and optimal fixed fire extinguishing systems were designed. Results : Maximum and minimum risks of fire were in chemical water and wastewater (81.2% and physical agents (62.5% laboratories, respectively. For studied laboratories, we designed fire detection systems based on heat and smoke detectors. Also in these places, fire-extinguishing systems based on CO2 were designed . Conclusion : Due to high risk of fire in studied laboratories, the best control method for fire prevention and protection based on special features of these laboratories is using automatic detection, warning and fire extinguishing systems using CO2 .

  13. Application of a modified OxiTop® respirometer for laboratory composting studies

    Directory of Open Access Journals (Sweden)

    Malińska Krystyna

    2016-03-01

    Full Text Available This study applied a modified OxiTop® system to determine the oxygen uptake rate during a 2-day respiration test of selected composting materials at different moisture contents, air-filled porosities and composition of composting mixtures. The modification of the OxiTop® respirometer included replacement and adjustment of a glass vessel (i.e. a 1.9-L glass vessel with wide mouth was used instead of a standard 1-L glass bottle, additionally the twist-off vessel lid was adjusted to attach the measuring head and application of a closed steel mesh cylinder of 5 cm in diameter and 10 cm in height with the open surface area of the mesh of approximately 56.2%. This modification allowed obtaining different bulk densities (and thus air-porosities of the investigated composting materials in laboratory composting studies. The test was performed for apple pomace and composting mixtures of apple pomace with wood chips at ratios of 1:0.5, 1:1, 1:1.5 (d.w, moisture contents of 60%, 65% and 75% and air-filled porosities ranging from 46% to 1%. Due to diverse biodegradability of the investigated apple pomace and composting mixtures this test allows for the determination of the effects of different air-porosities (due to compaction in a pile on the oxygen uptake rate for mixtures with a fixed ratio of a bulking agent. The described method allows for laboratory determination of the effects of moisture content and compaction on biodegradation dynamics during composting.

  14. Laboratory Experiments on Low-crested Breakwaters

    DEFF Research Database (Denmark)

    Kramer, Morten Mejlhede; Zanuttigh, B.; van der Meer, J. W.

    2004-01-01

    The ducument describe 3D tests at scale 1:20 performed in the Laboratory at Department of Civil Engineering, Aalborg University.The wave obliquity was one of the main parameters, which were studied in the wave basin experiments. The experiments provide unique information about the influences...... of this parameter where almost no research has been done before....

  15. Comparison of microbiological diagnosis of urinary tract infection in young children by routine health service laboratories and a research laboratory: Diagnostic cohort study.

    Directory of Open Access Journals (Sweden)

    Kate Birnie

    Full Text Available To compare the validity of diagnosis of urinary tract infection (UTI through urine culture between samples processed in routine health service laboratories and those processed in a research laboratory.We conducted a prospective diagnostic cohort study in 4808 acutely ill children aged <5 years attending UK primary health care. UTI, defined as pure/predominant growth ≥105 CFU/mL of a uropathogen (the reference standard, was diagnosed at routine health service laboratories and a central research laboratory by culture of urine samples. We calculated areas under the receiver-operator curve (AUC for UTI predicted by pre-specified symptoms, signs and dipstick test results (the "index test", separately according to whether samples were obtained by clean catch or nappy (diaper pads.251 (5.2% and 88 (1.8% children were classified as UTI positive by health service and research laboratories respectively. Agreement between laboratories was moderate (kappa = 0.36; 95% confidence interval [CI] 0.29, 0.43, and better for clean catch (0.54; 0.45, 0.63 than nappy pad samples (0.20; 0.12, 0.28. In clean catch samples, the AUC was lower for health service laboratories (AUC = 0.75; 95% CI 0.69, 0.80 than the research laboratory (0.86; 0.79, 0.92. Values of AUC were lower in nappy pad samples (0.65 [0.61, 0.70] and 0.79 [0.70, 0.88] for health service and research laboratory positivity, respectively than clean catch samples.The agreement of microbiological diagnosis of UTI comparing routine health service laboratories with a research laboratory was moderate for clean catch samples and poor for nappy pad samples and reliability is lower for nappy pad than for clean catch samples. Positive results from the research laboratory appear more likely to reflect real UTIs than those from routine health service laboratories, many of which (particularly from nappy pad samples could be due to contamination. Health service laboratories should consider adopting procedures used

  16. Comparison of microbiological diagnosis of urinary tract infection in young children by routine health service laboratories and a research laboratory: Diagnostic cohort study

    Science.gov (United States)

    Birnie, Kate; Hay, Alastair D.; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Whiting, Penny; Lawton, Michael; Delaney, Brendan; Downing, Harriet; Dudley, Jan; Hollingworth, William; Lisles, Catherine; Little, Paul; O’Brien, Kathryn; Pickles, Timothy; Rumsby, Kate; Thomas-Jones, Emma; Van der Voort, Judith; Waldron, Cherry-Ann; Harman, Kim; Hood, Kerenza; Butler, Christopher C.; Sterne, Jonathan A. C.

    2017-01-01

    Objectives To compare the validity of diagnosis of urinary tract infection (UTI) through urine culture between samples processed in routine health service laboratories and those processed in a research laboratory. Population and methods We conducted a prospective diagnostic cohort study in 4808 acutely ill children aged <5 years attending UK primary health care. UTI, defined as pure/predominant growth ≥105 CFU/mL of a uropathogen (the reference standard), was diagnosed at routine health service laboratories and a central research laboratory by culture of urine samples. We calculated areas under the receiver-operator curve (AUC) for UTI predicted by pre-specified symptoms, signs and dipstick test results (the “index test”), separately according to whether samples were obtained by clean catch or nappy (diaper) pads. Results 251 (5.2%) and 88 (1.8%) children were classified as UTI positive by health service and research laboratories respectively. Agreement between laboratories was moderate (kappa = 0.36; 95% confidence interval [CI] 0.29, 0.43), and better for clean catch (0.54; 0.45, 0.63) than nappy pad samples (0.20; 0.12, 0.28). In clean catch samples, the AUC was lower for health service laboratories (AUC = 0.75; 95% CI 0.69, 0.80) than the research laboratory (0.86; 0.79, 0.92). Values of AUC were lower in nappy pad samples (0.65 [0.61, 0.70] and 0.79 [0.70, 0.88] for health service and research laboratory positivity, respectively) than clean catch samples. Conclusions The agreement of microbiological diagnosis of UTI comparing routine health service laboratories with a research laboratory was moderate for clean catch samples and poor for nappy pad samples and reliability is lower for nappy pad than for clean catch samples. Positive results from the research laboratory appear more likely to reflect real UTIs than those from routine health service laboratories, many of which (particularly from nappy pad samples) could be due to contamination. Health service

  17. Components of laboratory accreditation.

    Science.gov (United States)

    Royal, P D

    1995-12-01

    Accreditation or certification is a recognition given to an operation or product that has been evaluated against a standard; be it regulatory or voluntary. The purpose of accreditation is to provide the consumer with a level of confidence in the quality of operation (process) and the product of an organization. Environmental Protection Agency/OCM has proposed the development of an accreditation program under National Environmental Laboratory Accreditation Program for Good Laboratory Practice (GLP) laboratories as a supplement to the current program. This proposal was the result of the Inspector General Office reports that identified weaknesses in the current operation. Several accreditation programs can be evaluated and common components identified when proposing a structure for accrediting a GLP system. An understanding of these components is useful in building that structure. Internationally accepted accreditation programs provide a template for building a U.S. GLP accreditation program. This presentation will discuss the traditional structure of accreditation as presented in the Organization of Economic Cooperative Development/GLP program, ISO-9000 Accreditation and ISO/IEC Guide 25 Standard, and the Canadian Association for Environmental Analytical Laboratories, which has a biological component. Most accreditation programs are managed by a recognized third party, either privately or with government oversight. Common components often include a formal review of required credentials to evaluate organizational structure, a site visit to evaluate the facility, and a performance evaluation to assess technical competence. Laboratory performance is measured against written standards and scored. A formal report is then sent to the laboratory indicating accreditation status. Usually, there is a scheduled reevaluation built into the program. Fee structures vary considerably and will need to be examined closely when building a GLP program.

  18. McMaster Accelerator Laboratory. Annual report 1987

    International Nuclear Information System (INIS)

    1987-01-01

    During the past year the trend has continued of diversification of the research programmes in the laboratory. Research using the techniques of accelerator mass spectrometry is flourishing and there is increased activity in the fields of surface science and nuclear medicine. The nuclear physics activity continues strong but at a reduced level. The FN accelerators performed excellently during the year and the nuclear physics programme benefitted from the acquisition of a computer-controlled analysing-magnet NMR. Surface science at McMaster University is involved with the Ontario Government Centre of Excellence in Materials Science. This will involve new equipment for studies in molecular beam epitaxy. The research studies in brain function is also another growing area in the laboratory

  19. Virtual Laboratory "vs." Traditional Laboratory: Which Is More Effective for Teaching Electrochemistry?

    Science.gov (United States)

    Hawkins, Ian; Phelps, Amy J.

    2013-01-01

    The use of virtual laboratories has become an increasing issue regarding science laboratories due to the increasing cost of hands-on laboratories, and the increase in distance education. Recent studies have looked at the use of virtual tools for laboratory to be used as supplements to the regular hands-on laboratories but many virtual tools have…

  20. Beat-wave accelerator studies at the Rutherford Appleton Laboratory

    International Nuclear Information System (INIS)

    Lawson, J.D.

    1985-01-01

    The study carried out in 1982-83 at the Rutherford Appleton Laboratory to examine how one might use the beat-wave principle to construct a useful high energy accelerator is reviewed, and comments are made on later developments. A number of problems are evident to which solutions cannot at present be foreseen. (author)

  1. Annual report of Laboratory of Nuclear Studies, Osaka University, for fiscal 1979

    International Nuclear Information System (INIS)

    1980-01-01

    This annual report presents the research activities carried out by the members of the Laboratory and the users of the facilities. The major facilities of the Laboratory are a 110 cm variable energy cyclotron and a 4.7 MeV Van de Graaff. The cyclotron division has made extensive studies on nuclear physics, such as the pre-equilibrium process of neutron emission, inelastic proton scattering, He-3 induced reactions, and polarization experiments. The Van de Graaff division reports about the works on hyperfine interaction, mirror beta-decay, heavy element ion source, and nuclear spin alignment. Model magnet study on the future project has also been developed at the Laboratory. Other divisions of the Laboratory are the mass spectroscopy division, the radioisotope division, and the theoretical physics division. The works of the mass spectroscopy division concern the on-line mass separation of radioisotopes, the field desorption of mass spectra, and instrumentation. The works of the radioisotope division spread widely on the field of nuclear chemistry. At the end of this report, various works, which have been made by the theoretical physics division, are introduced. (Kato, T.)

  2. Productivity of Veterans Health Administration laboratories: a College of American Pathologists Laboratory Management Index Program (LMIP) study.

    Science.gov (United States)

    Valenstein, Paul N; Wang, Edward; O'Donohue, Tom

    2003-12-01

    The Veterans Health Administration (VA) operates the largest integrated laboratory network in the United States. To assess whether the unique characteristics of VA laboratories impact efficiency of operations, we compared the productivity of VA and non-VA facilities. Financial and activity data were prospectively collected from 124 VA and 131 non-VA laboratories enrolled in the College of American Pathologists Laboratory Management Index Program (LMIP) during 2002. In addition, secular trends in 5 productivity ratios were calculated for VA and non-VA laboratories enrolled in LMIP from 1997 through 2002. Veterans Health Administration and non-VA facilities did not differ significantly in size. Inpatients accounted for a lower percentage of testing at VA facilities than non-VA facilities (21.7% vs 37.3%; P benefits; P depreciation, and maintenance than their non-VA counterparts (all P <.001), resulting in lower overall cost per on-site test result (2.64 dollars vs 3.40 dollars; P <.001). Cost per referred (sent-out) test did not differ significantly between the 2 groups. Analysis of 6-year trends showed significant increases in both VA (P <.001) and non-VA (P =.02) labor productivity (on-site tests/total FTE). Expenses at VA laboratories for labor per test, consumables per test, overall expense per test, and overall laboratory expense per discharge decreased significantly during the 6-year period (P <.001), while in non-VA facilities the corresponding ratios showed no significant change. Overall productivity of VA laboratories is superior to that of non-VA facilities enrolled in LMIP. The principal advantages enjoyed by the VA are higher-than-average labor productivity (tests/FTE) and lower-than-average consumable expenses.

  3. The changing face of clinical laboratories.

    Science.gov (United States)

    Plebani, M

    1999-07-01

    Laboratory medicine has undergone a sea change, and medical laboratories must now adapt to, and meet new, customer-supplier needs springing from shifts in the patterns of disease prevalence, medical practice, and demographics. Managed care and other cost-containment processes have forced those involved in health care to cooperate to develop a full picture of patient care, and this has affected clinical laboratory objectives, the main focus now being on improvement in medical outcomes. More recently, the resource shortages in health care and results of cost/effectiveness analysis have demonstrated that the value of a laboratory test must be ascertained not only on the basis of its chemical or clinical performance characteristics, but also by its impact on patient management, the only true assessment of the quality of testing being quality of patient outcomes. The time is ripe for changing the vision of laboratory medicine, and some of the reasons for this are the availability of results in real-time, the introduction of more specific tests, and the trend to prevent diseases rather than cure them. The information from laboratory tests designed to evaluate biochemical or genetic risk and/or prognostic factors cannot be replaced either by physical examination and/or the assessment of symptoms. Today, the importance of laboratory scientists must be proven in three broad areas: a) guaranteeing the quality of tests, irrespective of where they are performed; b) improving the quality of the service; c) maximizing the impact of laboratory information on patient management.

  4. Is there a First Night Effect on Sleep Bruxism? A Sleep Laboratory Study

    Science.gov (United States)

    Hasegawa, Yoko; Lavigne, Gilles; Rompré, Pierre; Kato, Takafumi; Urade, Masahiro; Huynh, Nelly

    2013-01-01

    Study Objectives: Sleep bruxism (SB) is reported to vary in frequency over time. The aim of this study was to assess the first night effect on SB. Methods: A retrospective polysomnographic (PSG) analysis was performed of data from a sample of SB patients (12 females, 4 males; age range: 17-39 years) recorded in a sleep laboratory over 2 consecutive nights. Sleep parameters and jaw muscle activity variables (i.e., rhythmic masticatory muscle activity [RMMA]) for SB were quantified and compared between the 2 nights. Subjects were classified into groups according to severity of RMMA frequency, such as low frequency (2-4 episodes/h and/or bruxism time index, and mean burst duration (repeated measure ANOVAs, p ≤ 0.05). Five patients of 8 in the low frequency group were classified into the moderate-high frequency group on the second night, whereas only one patient in the moderate-high frequency group moved to the low frequency group. Conclusions: The results showed no overall first night effect on severity of RMMA frequency in young and healthy patients with SB. In clinical practice, one-night sleep recording may be sufficient for moderate-high frequency SB patients. However, low RMMA frequency in the first night could be confirmed by a second night based on the patient's medical and dental history. Citation: Hasegawa Y; Lavigne G; Rompré P; Kato T; Urade M; Huynh N. Is there a first night effect on sleep bruxism? A sleep laboratory study. J Clin Sleep Med 2013;9(11):1139-1145. PMID:24235894

  5. [ISO 15189 accreditation in clinical microbiology laboratory: general concepts and the status in our laboratory].

    Science.gov (United States)

    Akyar, Işin

    2009-10-01

    One important trend in the laboratory profession and quality management is the global convergence of laboratory operations. The goal of an accredited medical laboratory is to continue "offering useful laboratory service for diagnosis and treatment of the patients and also aid to the health of the nation". An accredited clinical laboratory is managed by a quality control system, it is competent technically and the laboratory service meets the needs of all its patients and physicians by taking the responsibility of all the medical tests and therapies. For this purpose, ISO 15189 international standard has been prepared by 2003. ISO 15189 standard is originated from the arrangement of ISO 17025 and ISO 9001:2000 standards. Many countries such as England, Germany, France, Canada and Australia have preferred ISO 15189 as their own laboratory accreditation programme, meeting all the requirements of their medical laboratories. The accreditation performance of a clinical microbiology laboratory is mainly based on five essential points; preanalytical, analytical, postanalytical, quality control programmes (internal, external, interlaboratory) and audits (internal, external). In this review article, general concepts on ISO 15189 accreditation standards for the clinical microbiology laboratories have been summarized and the status of a private laboratory (Acibadem LabMed, Istanbul) in Turkey has been discussed.

  6. Cyclotron laboratory in the Institute of Nuclear Studies of the Hungarian Academy of Sciences

    International Nuclear Information System (INIS)

    Gal'chuk, A.V.; Korolev, L.E.; Stepanov, A.V.

    1985-01-01

    The status of the development of cyclotron laboratory in the Institute for Nuclear Research of the Hungarian Academy of Sciences is discussed. The MGTS-20Eh isochronous cyclotron is to be mounted in the laboratory. Obtaining of accelerated proton beams is planned (energy of 5-18 MeV, internal beam current - 200 μA, external beam current - 50 μA), deuterons (3-10 MeV, 300 μA, 50 μA), H 3 +2 ions (7-27 MeV, 50 μA, 25 μA) and He 4 +2 (6-20 MeV, 50 μA, 25 μA). Fundamental researches in the field of atomic and nuclear physics applied investigations in the field of analysis of high purity materials, radiobiological investigations in the field of medicine and agriculture are to be performed in the laboratory. The cyclotron is to be used for production and application of short-lived radioisotopes and radiation testing machine parts

  7. VALIDATION GUIDELINES FOR LABORATORIES PERFORMING FORENSIC ANALYSIS OF CHEMICAL TERRORISM

    Science.gov (United States)

    The Scientific Working Group on Forensic Analysis of Chemical Terrorism (SWGFACT) has developed the following guidelines for laboratories engaged in the forensic analysis of chemical evidence associated with terrorism. This document provides a baseline framework and guidance for...

  8. Performance of Kiestra total laboratory automation combined with MS in clinical microbiology practice

    NARCIS (Netherlands)

    Mutters, Nico T.; Hodiamont, Caspar J.; de Jong, Menno D.; Overmeijer, Hendri P. J.; van den Boogaard, Mandy; Visser, Caroline E.

    2014-01-01

    Microbiological laboratories seek technologically innovative solutions to cope with large numbers of samples and limited personnel and financial resources. One platform that has recently become available is the Kiestra Total Laboratory Automation (TLA) system (BD Kiestra B.V., the Netherlands). This

  9. Reduction of multi-dimensional laboratory data to a two-dimensional plot: a novel technique for the identification of laboratory error.

    Science.gov (United States)

    Kazmierczak, Steven C; Leen, Todd K; Erdogmus, Deniz; Carreira-Perpinan, Miguel A

    2007-01-01

    The clinical laboratory generates large amounts of patient-specific data. Detection of errors that arise during pre-analytical, analytical, and post-analytical processes is difficult. We performed a pilot study, utilizing a multidimensional data reduction technique, to assess the utility of this method for identifying errors in laboratory data. We evaluated 13,670 individual patient records collected over a 2-month period from hospital inpatients and outpatients. We utilized those patient records that contained a complete set of 14 different biochemical analytes. We used two-dimensional generative topographic mapping to project the 14-dimensional record to a two-dimensional space. The use of a two-dimensional generative topographic mapping technique to plot multi-analyte patient data as a two-dimensional graph allows for the rapid identification of potentially anomalous data. Although we performed a retrospective analysis, this technique has the benefit of being able to assess laboratory-generated data in real time, allowing for the rapid identification and correction of anomalous data before they are released to the physician. In addition, serial laboratory multi-analyte data for an individual patient can also be plotted as a two-dimensional plot. This tool might also be useful for assessing patient wellbeing and prognosis.

  10. Quality control for diagnostic oral microbiology laboratories in European countries

    Directory of Open Access Journals (Sweden)

    Andrew J. Smith

    2011-11-01

    Full Text Available Participation in diagnostic microbiology internal and external quality control (QC processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB Network was created. At the European Oral Microbiology Workshop in 2008, 12 laboratories processing clinical oral microbiological samples were identified. All these were recruited to participate into the study and six laboratories from six European countries completed both the online survey and the first QC round. Three additional laboratories participated in the second round. Based on the survey, European oral microbiology laboratories process a significant (mean per laboratory 4,135 number of diagnostic samples from the oral cavity annually. A majority of the laboratories did not participate in any internal or external QC programme and nearly half of the laboratories did not have standard operating procedures for the tests they performed. In both QC rounds, there was a large variation in the results, interpretation and reporting of antibiotic susceptibility testing among the laboratories. In conclusion, the results of this study demonstrate the need for harmonisation of laboratory processing methods and interpretation of results for oral microbiology specimens. The QC rounds highlighted the value of external QC in evaluating the efficacy and safety of processes, materials and methods used in the laboratory. The use of standardised methods is also a prerequisite for multi-centre epidemiological studies that can provide important information on emerging microbes and trends in anti-microbial susceptibility for empirical prescribing in oro-facial infections.

  11. Design Study of Low-Emittance Injector for SASE-XFEL at Pohang Accelerator Laboratory

    CERN Document Server

    Park, Sungju J; Yun, H J; Kim, D E; Kim, E S; Ko, In Soo; Nam, S H; Oh, Jong Seok

    2004-01-01

    We report on the design study of the low-emittance injector for the SASE-XFEL that is being considered as a possible choice for the next-generation light sources at the Pohang Accelerator Laboratory, POSTECH. Using the PARMELA code, beam dynamics simulations were performed aiming to achieve the invariant-envelope matching at booster entrance, and to insure beam emittance < 1 mm.mrad (at 1-nC bunch charge) at the injector end. We also utilized the MAGIC code for analyzing beam dynamics inside the RF-gun cavities and to confirm the part of PARMELA simulations. Hardware design was done with possible implementation of high-Q.E. photocathode, which could reduce burdens imposed on laser system, thus improving overall system stability and reliability.

  12. A Feasibility Study for Mobile Marketing and Distribution Occupational Laboratories in North Dakota.

    Science.gov (United States)

    Kohns, Donald P.

    A study determined the feasibility of a mobile laboratory for marketing and distribution in North Dakota. It attempted to answer four questions: (1) What types of staffing, equipment, curriculum, and delivery systems are presently being utilized in mobile laboratories throughout the nation? (2) What significant information obtained from mobile…

  13. LABORATORY EXAMINATION IN NERVE AGENT INTOXICATION

    Directory of Open Access Journals (Sweden)

    Jiří Bajgar

    2013-01-01

    Full Text Available Diagnosis of nerve agent intoxication is based on anamnestic data, clinical signs and laboratory examination. For acute poisoning, cholinesterase activity in the blood (erythrocyte AChE, plasma/serum BuChE is sensitive, simple and most frequent laboratory examination performed in biochemical laboratories. Specialized examinations to precise treatment (reactivation test or to make retrospective diagnosis (fluoride induced reactivation etc. can be conducted. Other sophisticated methods are available, too.

  14. Applied Neuroscience Laboratory Complex

    Data.gov (United States)

    Federal Laboratory Consortium — Located at WPAFB, Ohio, the Applied Neuroscience lab researches and develops technologies to optimize Airmen individual and team performance across all AF domains....

  15. LabPush: a pilot study of providing remote clinics with laboratory results via short message service (SMS in Swaziland, Africa.

    Directory of Open Access Journals (Sweden)

    Wen-Shan Jian

    Full Text Available BACKGROUND: Turnaround time (TAT is an important indicator of laboratory performance. It is often difficult to achieve fast TAT for blood tests conducted at clinics in developing countries. This is because clinics where the patient is treated are often far away from the laboratory, and transporting blood samples and test results between the two locations creates significant delay. Recent efforts have sought to mitigate this problem by using Short Message Service (SMS to reduce TAT. Studies reporting the impact of this technique have not been published in scientific literature however. In this paper we present a study of LabPush, a system developed to test whether SMS delivery of HIV related laboratory results to clinics could shorten TAT time significantly. METHOD: LapPush was implemented in six clinics of the Kingdom of Swaziland. SMS results were sent out from the laboratory as a supplement to normal transport of paper results. Each clinic was equipped with a mobile phone to receive SMS results. The laboratory that processes the blood tests was equipped with a system for digital input of results, and transmission of results via SMS to the clinics. RESULTS: Laboratory results were received for 1041 different clinical cases. The total number of SMS records received (1032 was higher than that of paper records (965, indicating a higher loss rate for paper records. A statistical comparison of TAT for SMS and paper reports indicates a statistically significant improvement for SMS. Results were more positive for more rural clinics, and an urban clinic with high workload. CONCLUSION: SMS can be used to reduce TAT for blood tests taken at clinics in developing countries. Benefits are likely to be greater at clinics that are further away from laboratories, due to the difficulties this imposes on transport of paper records.

  16. Cab technology integration laboratory demonstration with moving map technology

    Science.gov (United States)

    2013-03-31

    A human performance study was conducted at the John A. Volpe National Transportation Systems Center (Volpe Center) using a locomotive research simulatorthe Cab Technology Integration Laboratory (CTIL)that was acquired by the Federal Railroad Ad...

  17. Laboratory for Extraterrestrial Physics

    Science.gov (United States)

    Vondrak, Richard R. (Technical Monitor)

    2001-01-01

    The NASA Goddard Space Flight Center (GSFC) Laboratory for Extraterrestrial Physics (LEP) performs experimental and theoretical research on the heliosphere, the interstellar medium, and the magnetospheres and upper atmospheres of the planets, including Earth. LEP space scientists investigate the structure and dynamics of the magnetospheres of the planets including Earth. Their research programs encompass the magnetic fields intrinsic to many planetary bodies as well as their charged-particle environments and plasma-wave emissions. The LEP also conducts research into the nature of planetary ionospheres and their coupling to both the upper atmospheres and their magnetospheres. Finally, the LEP carries out a broad-based research program in heliospheric physics covering the origins of the solar wind, its propagation outward through the solar system all the way to its termination where it encounters the local interstellar medium. Special emphasis is placed on the study of solar coronal mass ejections (CME's), shock waves, and the structure and properties of the fast and slow solar wind. LEP planetary scientists study the chemistry and physics of planetary stratospheres and tropospheres and of solar system bodies including meteorites, asteroids, comets, and planets. The LEP conducts a focused program in astronomy, particularly in the infrared and in short as well as very long radio wavelengths. We also perform an extensive program of laboratory research, including spectroscopy and physical chemistry related to astronomical objects. The Laboratory proposes, develops, fabricates, and integrates experiments on Earth-orbiting, planetary, and heliospheric spacecraft to measure the characteristics of planetary atmospheres and magnetic fields, and electromagnetic fields and plasmas in space. We design and develop spectrometric instrumentation for continuum and spectral line observations in the x-ray, gamma-ray, infrared, and radio regimes; these are flown on spacecraft to study

  18. [Integrated skills laboratory concept for undergraduate training in internal medicine].

    Science.gov (United States)

    Nikendei, C; Schilling, T; Nawroth, P; Hensel, M; Ho, A D; Schwenger, V; Zeier, M; Herzog, W; Schellberg, D; Katus, H A; Dengler, T; Stremmel, W; Müller, M; Jünger, J

    2005-05-06

    An amendment to the German medical curriculum in April 2002 will place basic practical skills at the centre of medical training. We report here on the implementation and evaluation of an obligatory, tutor-guided, and integrated skills laboratory concept in the field of internal medicine. To test the effectiveness of a skills laboratory training on OSCE performance a pilot study was carried out. The experimental group, of 77 students, participated in seven sessions of communication training, skills laboratory training, and bedside teaching, each lasting one and a half hours. The control group of 66 students had as many sessions but was only offered bedside-teaching. The evaluation of acceptance of skills' training as well as the related increase in individual competence is on-going (summer term 2004: n = 176 students). The integrated skills laboratory concept was rated at 3.5 (SD = 1.2) on a 5-point scale and was acknowledged as practice-oriented (M = 4.2; SD = 1.0) and relevant for doctors' everyday lives (M = 3.6; SD = 1.1). Increased levels of competence according to individual self-evaluations proved to be highly significant (p<.001), and results of the pilot study showed that the experimental group had a significantly better OSCE performance than the control group (p<.001). This pilot study shows that curriculum changes promoting basic clinical skills are effective and lead to an improved practical education of tomorrow's physicians. The integrated skills laboratory concept is well accepted and leads to a relevant increase in competence in the practice of internal medical. The presented skills laboratory concept in internal medicine is proving to be a viable and efficient learning tool.

  19. Neutron Scattering Activity at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Bourke, M.A.M.

    2015-01-01

    The nondestructive and bulk penetrating aspects of neutron scattering techniques make them well suited to the study of materials from the nuclear energy sector (particularly those which are radioactive). This report provides a summary of the facility, LANSCE, which is used at Los Alamos National laboratory for these studies. It also provides a brief description of activities related to line broadening studies of radiation damage and recent imaging and offers observations about the outlook for future activity. The work alluded to below was performed during the period of the CRP by researchers that included but were not limited to; Sven Vogel and Don Brown of Los Alamos National Laboratory; and Anton Tremsin of the University of California, Berkeley. (author)

  20. Structural Dynamics Laboratory (SDL)

    Data.gov (United States)

    Federal Laboratory Consortium — Structural dynamic testing is performed to verify the survivability of a component or assembly when exposed to vibration stress screening, or a controlled simulation...

  1. A laboratory experimental setup for photo-absorption studies using synchrotron radiation

    CERN Document Server

    Shastri, A; Saraswati, P; Sunanda, K

    2002-01-01

    The photophysics beamline, which is being installed at the 450 MeV Synchrotron Radiation Source (SRS), Indus-l, is a medium resolution beamline useful for a variety of experiments in the VUV region viz. 500-2000 A. One of the major applications of this beamline is gas-phase photo-absorption studies. An experimental set up to be used for these experiments was designed, developed and tested in our laboratory. The setup consists of a high vacuum absorption cell, 1/4 m monochromator and detection system. For the purpose of testing, xenon and tungsten continuum sources were used and absorption spectra were recorded in the UV region. This setup was used to record the absorption spectrum of a few molecules like acetone, ammonia, benzene, formaldehyde and acetaldehyde in order to evaluate the performance of the experimental system which will subsequently be used with the photophysics beamline. Details of the design, fabrication and testing of the absorption cell and experimental procedures are presented in this repor...

  2. Prognostic classification with laboratory parameters or imaging techniques in small-cell lung cancer

    NARCIS (Netherlands)

    de Jong, Wouter K.; Fidler, Vaclav; Groen, Harry J. M.

    PURPOSE: Our aim in this study was to compare prognostic models based on laboratory tests with a model including imaging information in small-cell lung cancer. PATIENTS AND METHODS: A retrospective analysis was performed on 156 consecutive patients. Three existing models based on laboratory tests

  3. Battery Test Facility- Electrochemical Analysis and Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrochemical Analysis and Diagnostics Laboratory (EADL) provides battery developers with reliable, independent, and unbiased performance evaluations of their...

  4. Results of the Interlaboratory Exercise CNS/CIEMAT-2008 among Environmental Radioactivity Laboratories (Phosphogypsum)

    International Nuclear Information System (INIS)

    Romero, M. L.; Barrera, M.; Valino, F.

    2010-01-01

    The document describes the outcome of the CSN/CIEMAT-2008 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC. Aphosphogypsum material was used as a test sample, in an attempt to evaluate the performance of the laboratories analyzing NORM (Naturally-Occurring Radioactive Materials). The analysis required were: U-238, Th-234, U-234, Th-230, Ra-226, Pb-214, Bi-214, Pb-210, Po-210, Th-232 and U-235, and also gross alpha and gross beta activities. Reference values have been established according to the method of consensus of expert laboratories, with four international laboratories of credited experience: IAEA Seibersdorf, IAEA MEL, IRSN-Orsay and Sta.Teresa ENEA. The results of the exercise were computed for 34 answering laboratories and their analytical performance was assessed using the z-score. Robust statistics of the participants results was applied to obtain the median and standard deviation, to achieve a more complete and objective study of the laboratories performance. The exercise has shown an homogeneous behaviour of laboratories, being statistical parameters from the results close to the assigned Reference Values. Participant laboratories have demonstrated their ability to determine natural radionuclides in phosphogypsum samples (NORM material) with a satisfactory quality level. The scheme has also allowed examining the capability of laboratories to determine the activities of natural radionuclides at the equilibrium. (Author) 10 refs.

  5. Performance of mycological media in enumerating desiccated food spoilage yeasts: an interlaboratory study.

    Science.gov (United States)

    Beuchat, L R; Frandberg, E; Deak, T; Alzamora, S M; Chen, J; Guerrero, A S; López-Malo, A; Ohlsson, I; Olsen, M; Peinado, J M; Schnurer, J; de Siloniz, M I; Tornai-Lehoczki, J

    2001-10-22

    Dichloran 18% glycerol agar (DG18) was originally formulated to enumerate nonfastidious xerophilic moulds in foods containing rapidly growing Eurotium species. Some laboratories are now using DG18 as a general purpose medium for enumerating yeasts and moulds, although its performance in recovering yeasts from dry foods has not been evaluated. An interlaboratory study compared DG18 with dichloran rose bengal chloramphenicol agar (DRBC), plate count agar supplemented with chloramphenicol (PCAC), tryptone glucose yeast extract chloramphenicol agar (TGYC), acidified potato dextrose agar (APDA), and orange serum agar (OSA) for their suitability to enumerate 14 species of lyophilized yeasts. The coefficient of variation for among-laboratories repeatability within yeast was 1.39% and reproducibility of counts among laboratories was 7.1%. The order of performance of media for recovering yeasts was TGYC > PCAC = OSA > APDA > DRBC > DG 18. A second study was done to determine the combined effects of storage time and temperature on viability of yeasts and suitability of media for recovery. Higher viability was retained at -18 degrees C than at 5 degrees C or 25 degrees C for up to 42 weeks, although the difference in mean counts of yeasts stored at -18 degrees C and 25 degrees C was only 0.78 log10 cfu/ml of rehydrated suspension. TGYC was equal to PCAC and superior to the other four media in recovering yeasts stored at -18 degrees C, 5 degrees C, or 25 degrees C for up to 42 weeks. Results from both the interlaboratory study and the storage study support the use of TGYC for enumerating desiccated yeasts. DG18 is not recommended as a general purpose medium for recovering yeasts from a desiccated condition.

  6. The Laboratories at Seibersdorf: Multi-disciplinary research and support centre

    International Nuclear Information System (INIS)

    Danesi, P.R.

    1987-01-01

    The main research activities performed at the IAEA laboratories at Seibersdorf in the Agriculture Laboratory, Physics-Chemistry-Instrumentation Laboratory and Safeguards Analytical Laboratory, as well as the training activities are briefly described

  7. A Map for Clinical Laboratories Management Indicators in the Intelligent Dashboard.

    Science.gov (United States)

    Azadmanjir, Zahra; Torabi, Mashallah; Safdari, Reza; Bayat, Maryam; Golmahi, Fatemeh

    2015-08-01

    management challenges of clinical laboratories are more complicated for educational hospital clinical laboratories. Managers can use tools of business intelligence (BI), such as information dashboards that provide the possibility of intelligent decision-making and problem solving about increasing income, reducing spending, utilization management and even improving quality. Critical phase of dashboard design is setting indicators and modeling causal relations between them. The paper describes the process of creating a map for laboratory dashboard. the study is one part of an action research that begins from 2012 by innovation initiative for implementing laboratory intelligent dashboard. Laboratories management problems were determined in educational hospitals by the brainstorming sessions. Then, with regard to the problems key performance indicators (KPIs) specified. the map of indicators designed in form of three layered. They have a causal relationship so that issues measured in the subsequent layers affect issues measured in the prime layers. the proposed indicator map can be the base of performance monitoring. However, these indicators can be modified to improve during iterations of dashboard designing process.

  8. Using performance tasks employing IOM patient safety competencies to introduce quality improvement processes in medical laboratory science education.

    Science.gov (United States)

    Golemboski, Karen; Otto, Catherine N; Morris, Susan

    2013-01-01

    In order to contribute to improved healthcare quality through patient-centered care, laboratory professionals at all levels of practice must be able to recognize the connection between non-analytical factors and laboratory analysis, in the context of patient outcomes and quality improvement. These practices require qualities such as critical thinking (CT), teamwork skills, and familiarity with the quality improvement process, which will be essential for the development of evidence-based laboratory science practice. Performance tasks (PT) are an educational strategy which can be used to teach and assess CT and teamwork, while introducing Medical Laboratory Science (MLS) students at both baccalaureate and advanced-practice levels to the concepts of quality improvement processes and patient outcomes research. PT presents students with complex, realistic scenarios which require the incorporation of subject-specific knowledge with competencies such as effective team communication, patient-centered care, and successful use of information technology. A PT with assessment rubric was designed for use in a baccalaureate-level MLS program to teach and assess CT and teamwork competency. The results indicated that, even when students were able to integrate subject-specific knowledge in creative ways, their understanding of teamwork and quality improvement was limited. This indicates the need to intentionally teach skills such as collaboration and quality system design. PT represent one of many strategies that may be used in MLS education to develop essential professional competencies, encourage expert practice, and facilitate quality improvement.

  9. Blended learning within an undergraduate exercise physiology laboratory.

    Science.gov (United States)

    Elmer, Steven J; Carter, Kathryn R; Armga, Austin J; Carter, Jason R

    2016-03-01

    In physiological education, blended course formats (integration of face-to-face and online instruction) can facilitate increased student learning, performance, and satisfaction in classroom settings. There is limited evidence on the effectiveness of using blending course formats in laboratory settings. We evaluated the impact of blended learning on student performance and perceptions in an undergraduate exercise physiology laboratory. Using a randomized, crossover design, four laboratory topics were delivered in either a blended or traditional format. For blended laboratories, content was offloaded to self-paced video demonstrations (∼15 min). Laboratory section 1 (n = 16) completed blended laboratories for 1) neuromuscular power and 2) blood lactate, whereas section 2 (n = 17) completed blended laboratories for 1) maximal O2 consumption and 2) muscle electromyography. Both sections completed the same assignments (scored in a blinded manner using a standardized rubric) and practicum exams (evaluated by two independent investigators). Pre- and postcourse surveys were used to assess student perceptions. Most students (∼79%) watched videos for both blended laboratories. Assignment scores did not differ between blended and traditional laboratories (P = 0.62) or between sections (P = 0.91). Practicum scores did not differ between sections (both P > 0.05). At the end of the course, students' perceived value of the blended format increased (P learning key foundational content through video demonstrations before class greatly enhanced their learning of course material compared with a preassigned reading (94% vs. 78%, P Blended exercise physiology laboratories provided an alternative method for delivering content that was favorably perceived by students and did not compromise student performance. Copyright © 2016 The American Physiological Society.

  10. Results of the Interlaboratory Exercise CNS/CIEMAT-04 Among Environmental Radioactivity Laboratories (Aqueous Solution)

    International Nuclear Information System (INIS)

    Romero Gonzalez, M. L.; Barrera Izquierdo, M.

    2004-01-01

    The document describes the outcome of the CSN/CIEMAT-04 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonised Protocol for the proficiency testing of analytical laboratories. Following the issue of the European Community Drinking Water Directive 98/83/EC concerning the quality of water for human consumption, the last inter-comparison exercise was organised by using a water sample, in an attempt to evaluate the performance of the laboratories analysing the required radioactivity parameters (H-3, gross alpha and beta activity and residual beta). The sample (a synthetic drinking water), was prepared at the National Laboratory for Ionising Radiation's Standards (CIEMAT), and contained the following radionuclides ''241 Am, ''239+240 Pu, ''90Sr, ''137 Cs, ''3 H y ''40 K. The results of the exercise were computed for 38 participating laboratories, and their analytical performance was assessed using the z-score approach. Robust statistics of the participant's results was applied to obtain the median and standard deviation, including suspected outliers. The exercise has revealed and homogeneous behaviour of laboratories, being statistical parameters from the results close to the reference values. A raised percentage os satisfactory laboratory performance has been obtained for gross alpha, gross beta and residual beta: 85, 97 and 87% respectively. The study has shown that participant laboratories perform radioactive determinations in drinking water samples with satisfactory quality levels. (Author) 16 refs

  11. A Laboratory Course in Technological Chemistry.

    Science.gov (United States)

    Wiseman, P.

    1986-01-01

    Describes a laboratory course taught at the University of Manchester Institute of Science and Technology (United Kingdom) which focuses on the preparation, properties, and applications of end-use products of the chemical industry. Outlines laboratory experiments on dyes, fibers, herbicides, performance testing, antioxidants, and surface active…

  12. Implementing the Science Assessment Standards: Developing and validating a set of laboratory assessment tasks in high school biology

    Science.gov (United States)

    Saha, Gouranga Chandra

    Very often a number of factors, especially time, space and money, deter many science educators from using inquiry-based, hands-on, laboratory practical tasks as alternative assessment instruments in science. A shortage of valid inquiry-based laboratory tasks for high school biology has been cited. Driven by this need, this study addressed the following three research questions: (1) How can laboratory-based performance tasks be designed and developed that are doable by students for whom they are designed/written? (2) Do student responses to the laboratory-based performance tasks validly represent at least some of the intended process skills that new biology learning goals want students to acquire? (3) Are the laboratory-based performance tasks psychometrically consistent as individual tasks and as a set? To answer these questions, three tasks were used from the six biology tasks initially designed and developed by an iterative process of trial testing. Analyses of data from 224 students showed that performance-based laboratory tasks that are doable by all students require careful and iterative process of development. Although the students demonstrated more skill in performing than planning and reasoning, their performances at the item level were very poor for some items. Possible reasons for the poor performances have been discussed and suggestions on how to remediate the deficiencies have been made. Empirical evidences for validity and reliability of the instrument have been presented both from the classical and the modern validity criteria point of view. Limitations of the study have been identified. Finally implications of the study and directions for further research have been discussed.

  13. Study on explosives and their quality performance

    Energy Technology Data Exchange (ETDEWEB)

    Nabiullah, M.; Pingua, B.M.P.; Jagdish Khan, M.; Emranuzzaman [Central Mining Research Institute, Dhanbad (India)

    2005-07-01

    There are about forty suppliers of explosive and blasting accessories in India manufacturing site mixed emulsion, site mixed slurry, ANFO, HANFO, packed products, and blasting accessories of use in surface and underground mines. A field laboratory was set up to measure explosive properties of explosive samples, cast booster, detonating fuse, detonators, cord relay, MS connector, and shock tubes. Density, velocity of detonation, water percentage, water resistance, and energy output were considered as the important properties of explosives. A rating system was designed for selection of good explosive products. The delay interval and delay scattering in cord relay and shock tube was studied to improve blast performance. This paper describes in detail the method of measurement and vender rating system for explosive products as per marking system accepted by Coal India. 12 refs., 4 figs., 22 tabs.

  14. [Errors in laboratory daily practice].

    Science.gov (United States)

    Larrose, C; Le Carrer, D

    2007-01-01

    Legislation set by GBEA (Guide de bonne exécution des analyses) requires that, before performing analysis, the laboratory directors have to check both the nature of the samples and the patients identity. The data processing of requisition forms, which identifies key errors, was established in 2000 and in 2002 by the specialized biochemistry laboratory, also with the contribution of the reception centre for biological samples. The laboratories follow a strict criteria of defining acceptability as a starting point for the reception to then check requisition forms and biological samples. All errors are logged into the laboratory database and analysis report are sent to the care unit specifying the problems and the consequences they have on the analysis. The data is then assessed by the laboratory directors to produce monthly or annual statistical reports. This indicates the number of errors, which are then indexed to patient files to reveal the specific problem areas, therefore allowing the laboratory directors to teach the nurses and enable corrective action.

  15. A LabVIEW based Remote DSP Laboratory

    Directory of Open Access Journals (Sweden)

    Athanasios Kalantzopoulos

    2008-07-01

    Full Text Available Remote laboratories provide the students with the capability to perform laboratory exercises exploiting the relevant equipment any time of the day without their physical presence. Furthermore, providing the ability to use a single workstation by more than one student, they contribute to the reduction of the laboratory cost. Turning to advantage the above and according to the needs of post graduate modules in the fields of DSP Systems Design and Signal Processing Systems with DSPs, we designed and developed a Remote DSP Laboratory. A student using a Web Browser has the ability via internet to turn to account the R-DSP Lab and perform experiments using DSPs (Digital Signal Processors. For now, there is the opportunity to carry out laboratory exercises such as FIR, IIR digital filters and FFT as well as run any executable file developed by the user. In any case the observation of the results is carried out through the use of specially designed Graphical User Interfaces (GUIs.

  16. Adaptive laboratory evolution – principles and applications for biotechnology

    Science.gov (United States)

    2013-01-01

    Adaptive laboratory evolution is a frequent method in biological studies to gain insights into the basic mechanisms of molecular evolution and adaptive changes that accumulate in microbial populations during long term selection under specified growth conditions. Although regularly performed for more than 25 years, the advent of transcript and cheap next-generation sequencing technologies has resulted in many recent studies, which successfully applied this technique in order to engineer microbial cells for biotechnological applications. Adaptive laboratory evolution has some major benefits as compared with classical genetic engineering but also some inherent limitations. However, recent studies show how some of the limitations may be overcome in order to successfully incorporate adaptive laboratory evolution in microbial cell factory design. Over the last two decades important insights into nutrient and stress metabolism of relevant model species were acquired, whereas some other aspects such as niche-specific differences of non-conventional cell factories are not completely understood. Altogether the current status and its future perspectives highlight the importance and potential of adaptive laboratory evolution as approach in biotechnological engineering. PMID:23815749

  17. Key performance indicators score (KPIs-score) based on clinical and laboratorial parameters can establish benchmarks for internal quality control in an ART program.

    Science.gov (United States)

    Franco, José G; Petersen, Claudia G; Mauri, Ana L; Vagnini, Laura D; Renzi, Adriana; Petersen, Bruna; Mattila, M C; Comar, Vanessa A; Ricci, Juliana; Dieamant, Felipe; Oliveira, João Batista A; Baruffi, Ricardo L R

    2017-06-01

    KPIs have been employed for internal quality control (IQC) in ART. However, clinical KPIs (C-KPIs) such as age, AMH and number of oocytes collected are never added to laboratory KPIs (L-KPIs), such as fertilization rate and morphological quality of the embryos for analysis, even though the final endpoint is the evaluation of clinical pregnancy rates. This paper analyzed if a KPIs-score strategy with clinical and laboratorial parameters could be used to establish benchmarks for IQC in ART cycles. In this prospective cohort study, 280 patients (36.4±4.3years) underwent ART. The total KPIs-score was obtained by the analysis of age, AMH (AMH Gen II ELISA/pre-mixing modified, Beckman Coulter Inc.), number of metaphase-II oocytes, fertilization rates and morphological quality of the embryonic lot. The total KPIs-score (C-KPIs+L-KPIs) was correlated with the presence or absence of clinical pregnancy. The relationship between the C-KPIs and L-KPIs scores was analyzed to establish quality standards, to increase the performance of clinical and laboratorial processes in ART. The logistic regression model (LRM), with respect to pregnancy and total KPIs-score (280 patients/102 clinical pregnancies), yielded an odds ratio of 1.24 (95%CI = 1.16-1.32). There was also a significant difference (pclinical pregnancies (total KPIs-score=20.4±3.7) and the group without clinical pregnancies (total KPIs-score=15.9±5). Clinical pregnancy probabilities (CPP) can be obtained using the LRM (prediction key) with the total KPIs-score as a predictor variable. The mean C-KPIs and L-KPIs scores obtained in the pregnancy group were 11.9±2.9 and 8.5±1.7, respectively. Routinely, in all cases where the C-KPIs score was ≥9, after the procedure, the L-KPIs score obtained was ≤6, a revision of the laboratory procedure was performed to assess quality standards. This total KPIs-score could set up benchmarks for clinical pregnancy. Moreover, IQC can use C-KPIs and L-KPIs scores to detect problems

  18. Associations between physical examination, laboratory, and radiographic findings and outcome and subsequent racing performance of foals with Rhodococcus equi infection: 115 cases (1984-1992)

    International Nuclear Information System (INIS)

    Ainsworth, D.M.; Eicker, S.W.; Yeager, A.E.; Sweeney, C.R.; Viel, L.; Tesarowski, D.; Lavoie, J.P.; Hoffman, A.; Paradis, M.R.; Reed, S.M.

    1998-01-01

    Objective-To determine whether physical examination, laboratory, or radiographic abnormalities in foals with Rhodococcus equi infection were associated with survival, ability to race at least once after recovery, or, for foals that survived and went on to race, subsequent Facing performance. Design-Retrospective study. Animals-49 Thoroughbreds and 66 Standardbreds admitted to 1 of 6 veterinary teaching hospitals between 1984 and 1992 in which R equi infection was positively diagnosed. Procedure-Results of physical examination, laboratory testing, and thoracic radiography were reviewed. Indices of Facing performance were obtained for feats that recovered and eventually raced and compared with values for the US racing population. Results-83 (72%) feats survived. Foals that did not survive were more likely to have extreme tachycardia (heart rate > 100 beats/min), be in respiratory distress, and have severe radiographic abnormalities on thoracic radiographs at the time of initial examination than were foals that survived. Clinicopathologic abnormalities were not associated with whether feats did or did not survive. Forty-five of the 83 surviving foals (54%) eventually raced at least once, but none of the factors examined was associated with whether foals went on to race. Racing performance of foals that raced as adults was not significantly different from that of the US racing population. Clinical Implications-R equi infection in foals is associated with a decreased chance of racing as an adult, however, foals that eventually go on to race perform comparably to the US racing population

  19. Desempenho analítico de laboratórios prestadores de serviço na determinação de metais em águas Analytical performance of contractor laboratories in the determination of metals in water

    Directory of Open Access Journals (Sweden)

    Wilson F. Jardim

    2009-01-01

    Full Text Available Analytical laboratories are expected to produce reliable results. Decision makers are guided in their actions (financial, legal and environmental using analytical data provided by numerous laboratories. This work aimed to evaluate the analytical performance of Brazilian laboratories on producing trustworthy results. Nineteen laboratories, accredited and non-accredited ones, were contracted to analyze a USGS (United States Geological Survey certified water sample for 17 chemical elements (mostly metals without knowing the origin of the sample. Considering all the results produced, only 35% of them were valid. Three laboratories present satisfactory performances, whereas the majority showed a very poor overall performance. The outcomes of this work show the need for a more effective analytical quality program to Brazilian laboratories.

  20. Laboratory and field based evaluation of chromatography related performance of the Monitor for AeRosols and Gases in ambient Air (MARGA)

    Science.gov (United States)

    The semi-continuous Monitor for AeRosols and Gases in Ambient air (MARGA) was evaluated using laboratory and field data with a focus on chromatography. The performance and accuracy assessment revealed various errors and uncertainties resulting from mis-identification and mis-int...

  1. Using Virtual Laboratories as Interactive Textbooks: Studies on Blended Learning in Biotechnology Classrooms

    Directory of Open Access Journals (Sweden)

    Hemalatha Sasidharakurup

    2015-07-01

    Full Text Available Virtual laboratories, an ICT-based initiative, is a new venture that is becoming more prevalent in universities for improving classroom education. With geographically remote and economically constrained institutes in India as the focus, we developed web-based virtual labs for virtualizing the wet-lab techniques and experiments with the aid of graphics favoured animations, mathematical simulators and remote triggered experimentations. In this paper, we analysed perceived usefulness of Biotechnology virtual labs amongst student groups and its role in improving the student’s performance when introduced as a learning tool in a blended classroom scenario. A pedagogical survey, via workshops and online feedback, was carried out among 600 university-level students and 100 remote users of various Indian universities. Comparing learning groups on usage of blended learning approach against a control group (traditional classroom methods and an experimental group (teacher-mediated virtual labs, our studies indicate augmented academic performance among students in blended environments. Findings also indicated usage of remotely-triggered labs aided enhancing interaction-based lab education enabling anytime-anywhere student participation scenarios.

  2. Performance testing of extremity dosimeters, Study 2

    International Nuclear Information System (INIS)

    Harty, R.; Reece, W.D.; Hooker, C.D.

    1990-04-01

    The Health Physics Society Standards Committee (HPSSC) Working Group on Performance Testing of Extremity Dosimeters has issued a draft of a proposed standard for extremity dosimeters. The draft standard proposes methods to be used for testing dosimetry systems that determine occupational radiation dose to the extremities and the performance criterion used to determine compliance with the standard. Pacific Northwest Laboratory (PNL) has conducted two separate evaluations of the performance of extremity dosimeter processors to determine the appropriateness of the draft standard, as well as to obtain information regarding the performance of extremity dosimeters. Based on the information obtained during the facility visits and the results obtained from the performance testing, it was recommended that changes be made to ensure that the draft standard is appropriate for extremity dosimeters. The changes include: subdividing the mixture category and the beta particle category; eliminating the neutron category until appropriate flux-to-dose equivalent conversion factors are derived; and changing the tolerance level for the performance criterion to provide consistency with the performance criterion for whole body dosimeters, and to avoid making the draft standard overly difficult for processors of extremity dosimeters to pass. 20 refs., 10 figs., 6 tabs

  3. Selection criteria limit generalizability of smoking pharmacotherapy studies differentially across clinical trials and laboratory studies: A systematic review on varenicline.

    Science.gov (United States)

    Motschman, Courtney A; Gass, Julie C; Wray, Jennifer M; Germeroth, Lisa J; Schlienz, Nicolas J; Munoz, Diana A; Moore, Faith E; Rhodes, Jessica D; Hawk, Larry W; Tiffany, Stephen T

    2016-12-01

    The selection criteria used in clinical trials for smoking cessation and in laboratory studies that seek to understand mechanisms responsible for treatment outcomes may limit their generalizability to one another and to the general population. We reviewed studies on varenicline versus placebo and compared eligibility criteria and participant characteristics of clinical trials (N=23) and laboratory studies (N=22) across study type and to nationally representative survey data on adult, daily USA smokers (2014 National Health Interview Survey; 2014 National Survey on Drug Use and Health). Relative to laboratory studies, clinical trials more commonly reported excluding smokers who were unmotivated to quit and for specific medical conditions (e.g., cardiovascular disease, COPD), although both study types frequently reported excluding for general medical or psychiatric reasons. Laboratory versus clinical samples smoked less, had lower nicotine dependence, were younger, and more homogeneous with respect to smoking level and nicotine dependence. Application of common eligibility criteria to national survey data resulted in considerable elimination of the daily-smoking population for both clinical trials (≥47%) and laboratory studies (≥39%). Relative to the target population, studies in this review recruited participants who smoked considerably more and had a later smoking onset age, and were under-representative of Caucasians. Results suggest that selection criteria of varenicline studies limit generalizability in meaningful ways, and differences in criteria across study type may undermine efforts at translational research. Recommendations for improvements in participant selection and reporting standards are discussed. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. LEAN LABORATORY APPROACHES FOR QUALITY ASSURANCE IN FOOD

    Directory of Open Access Journals (Sweden)

    Laxmana Naik

    2011-09-01

    Full Text Available A lean laboratory is one which is focused on testing products and materials to deliver results in the most efficient way in terms of cost or speed or both; primarily focused on improving measurable performance and reducing costs. The goal of a lean laboratory is to use less effort, less resources and less time to test incoming samples. Laboratories have a critical role to play in establishing and improving process capability and key performance indicator (KPI of the organization. There are inevitably many opinions as to what a lean lab actually is; here is one version fr om. Quality assurance laboratories are crucial to the success of organization and this effectiveness needs to be measurable and demonstrable. To facilitate this, a method of measuring a laboratory's progress towards complete deployment has been created by lean tools. These tools allow laboratories to conduct gap analysis and identify opportunities for improvement.

  5. Clinical laboratory: bigger is not always better.

    Science.gov (United States)

    Plebani, Mario

    2018-06-27

    Laboratory services around the world are undergoing substantial consolidation and changes through mechanisms ranging from mergers, acquisitions and outsourcing, primarily based on expectations to improve efficiency, increasing volumes and reducing the cost per test. However, the relationship between volume and costs is not linear and numerous variables influence the end cost per test. In particular, the relationship between volumes and costs does not span the entire platter of clinical laboratories: high costs are associated with low volumes up to a threshold of 1 million test per year. Over this threshold, there is no linear association between volumes and costs, as laboratory organization rather than test volume more significantly affects the final costs. Currently, data on laboratory errors and associated diagnostic errors and risk for patient harm emphasize the need for a paradigmatic shift: from a focus on volumes and efficiency to a patient-centered vision restoring the nature of laboratory services as an integral part of the diagnostic and therapy process. Process and outcome quality indicators are effective tools to measure and improve laboratory services, by stimulating a competition based on intra- and extra-analytical performance specifications, intermediate outcomes and customer satisfaction. Rather than competing with economic value, clinical laboratories should adopt a strategy based on a set of harmonized quality indicators and performance specifications, active laboratory stewardship, and improved patient safety.

  6. Customer satisfaction survey with clinical laboratory and phlebotomy services at a tertiary care unit level.

    Science.gov (United States)

    Koh, Young Rae; Kim, Shine Young; Kim, In Suk; Chang, Chulhun L; Lee, Eun Yup; Son, Han Chul; Kim, Hyung Hoi

    2014-09-01

    We performed customer satisfaction surveys for physicians and nurses regarding clinical laboratory services, and for outpatients who used phlebotomy services at a tertiary care unit level to evaluate our clinical laboratory and phlebotomy services. Thus, we wish to share our experiences with the customer satisfaction survey for clinical laboratory and phlebotomy services. Board members of our laboratory designed a study procedure and study population, and developed two types of questionnaire. A satisfaction survey for clinical laboratory services was conducted with 370 physicians and 125 nurses by using an online or paper questionnaire. The satisfaction survey for phlebotomy services was performed with 347 outpatients who received phlebotomy services by using computer-aided interviews. Mean satisfaction scores of physicians and nurses was 58.1, while outpatients' satisfaction score was 70.5. We identified several dissatisfactions with our clinical laboratory and phlebotomy services. First, physicians and nurses were most dissatisfied with the specimen collection and delivery process. Second, physicians and nurses were dissatisfied with phlebotomy services. Third, molecular genetic and cytogenetic tests were found more expensive than other tests. This study is significant in that it describes the first reference survey that offers a survey procedure and questionnaire to assess customer satisfaction with clinical laboratory and phlebotomy services at a tertiary care unit level.

  7. Region 7 Laboratory Information Management System

    Science.gov (United States)

    This is metadata documentation for the Region 7 Laboratory Information Management System (R7LIMS) which maintains records for the Regional Laboratory. Any Laboratory analytical work performed is stored in this system which replaces LIMS-Lite, and before that LAST. The EPA and its contractors may use this database. The Office of Policy & Management (PLMG) Division at EPA Region 7 is the primary managing entity; contractors can access this database but it is not accessible to the public.

  8. Laboratory simulation of space plasma phenomena*

    Science.gov (United States)

    Amatucci, B.; Tejero, E. M.; Ganguli, G.; Blackwell, D.; Enloe, C. L.; Gillman, E.; Walker, D.; Gatling, G.

    2017-12-01

    Laboratory devices, such as the Naval Research Laboratory's Space Physics Simulation Chamber, are large-scale experiments dedicated to the creation of large-volume plasmas with parameters realistically scaled to those found in various regions of the near-Earth space plasma environment. Such devices make valuable contributions to the understanding of space plasmas by investigating phenomena under carefully controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. By working in collaboration with in situ experimentalists to create realistic conditions scaled to those found during the observations of interest, the microphysics responsible for the observed events can be investigated in detail not possible in space. To date, numerous investigations of phenomena such as plasma waves, wave-particle interactions, and particle energization have been successfully performed in the laboratory. In addition to investigations such as plasma wave and instability studies, the laboratory devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this presentation, we will describe several examples of the laboratory investigation of space plasma waves and instabilities and diagnostic development. *This work supported by the NRL Base Program.

  9. Validation in the cytopathology laboratory: its time has come.

    Science.gov (United States)

    Haack, Lori A; Shalkham, John

    2007-08-01

    The cytology laboratory has traditionally performed a relatively small variety of tests. The testing processes employed were generally manually performed and included preparation of glass slide materials, staining of these slides, coverslipping, and microscopic evaluation of the cellular material. Instrumentation in the cytology laboratory was very limited and included a centrifuge, membrane filtration system, and possibly an automated staining machine. If instruments were added, for example, a liquid based preparation device or an automated coverslipping device; the instruments were rarely checked to assure they were operating properly before implementation into clinical practice. In addition, little documentation was maintained with regards to the instrument performance evaluation process. Increasing automation and expansion of testing options have changed how cytopathology is practiced. There are many new devices employed for the preparation of specimens, staining and coverslipping of slides, and evaluation of cellular material. The increasing use of molecular testing methods in cytopathology further adds to the changing landscape of cytopathology. New instrumentation and testing methods are routinely being introduced and the cytopathology laboratory must assure that the testing performed is accurate and consistent. Cytopathology laboratory professionals need to appreciate the value of validation of the tests we perform and the instruments we use in order to best serve the patient. Our clinical laboratory colleagues have traditionally performed validation on both instruments and test methods before using them for clinical testing. If cytopathology wants to perform the complex testing being introduced and effectively utilize new instrumentation, we need to understand the value of validation and how we apply validation to our laboratory practice. Copyright 2007 Wiley-Liss, Inc.

  10. Laboratory studies of oil spill bioremediation; toward understanding field behavior

    International Nuclear Information System (INIS)

    Prince, R.C.; Hinton, S.M.; Elmendorf, D.L.; Lute, J.R.; Grossman, M.J.; Robbins, W.K.; Hsu, Chang S.; Richard, B.E.; Haith, C.E.; Senius, J.D.; Minak-Bernero, V.; Chianelli, R.R.; Bragg, J.R.; Douglas, G.S.

    1993-01-01

    Oil spill remediation aims to enhance the natural process of microbial hydrocarbon biodegradation. The microbial foundations have been studied throughout this century, but the focus of most of this work has been on the degradation of well defined compounds by well defined microbial species. This paper addresses laboratory studies on crude oil biodegradation by microbial consortia obtained from oiled beaches in Prince William Sound, Alaska following the spill from the Exxon Valdez. It demonstrates that oil degradation is indeed likely to be nitrogen-limited in Prince William Sound, the different molecular classes in crude oil that are subjected to biodegradation, the identification of conserved species in the oil that can be used for assessing biodegradation and bioremediation in the field, the effectiveness of fertilizers in stimulating sub-surface biodegradation, the role of the olephilic fertilizer Inipol EAP22, and the identification of the oil-degrading microorganisms in Prince William Sound. Together, these laboratory studies provided guidance and important insights into the microbial phenomena underlying the successful bioremediation of the oiled shorelines

  11. Radiation chemistry in the nuclear power reactor environment: from laboratory study to practical application

    International Nuclear Information System (INIS)

    Stuart, C.R.

    1999-01-01

    This paper discusses the work carried out at the Chalk River Nuclear Laboratories in underlying and applied radiation chemical research performed to optimise the processes occurring in the four aqueous systems in and around the core. The aqueous systems subject to radiolysis in CANDU reactors are Heat Transport System, Moderator, Liquid Zone Controls and End Shields.

  12. An ECVAG inter-laboratory validation study of the comet assay

    DEFF Research Database (Denmark)

    Ersson, Clara; Møller, Peter; Forchhammer, Lykke

    2013-01-01

    of ionising radiation, inter-laboratory variation, intra-laboratory variation and residual variation contributed to 60.9, 19.4, 0.1 and 19.5%, respectively, of the total variation. In the coded PBMC samples, the inter-laboratory variation explained the largest fraction of the overall variation of DNA strand...

  13. Phthalocyanine identification in paintings by reflectance spectroscopy. A laboratory and in situ study

    Science.gov (United States)

    Poldi, G.; Caglio, S.

    2013-06-01

    The importance of identifying pigments using non invasive (n.i.) analyses has gained increasing importance in the field of spectroscopy applied to art conservation and art studies. Among the large set of pigments synthesized and marketed during 20th century, surely phthalocyanine blue and green pigments occupy an important role in the field of painting (including restoration) and printing, thanks to their characteristics like brightness and fastness. This research focused on the most used phthalocyanine blue (PB15:1 and PB15:3) and green pigments (PG7), and on the possibility to identify these organic compounds using a methodology like reflectance spectroscopy in the UV, visible and near IR range (UV-vis-NIR RS), performed easily through portable instruments. Laboratory tests and three examples carried out on real paintings are discussed.

  14. Testing activities at the National Battery Test Laboratory

    Science.gov (United States)

    Hornstra, F.; Deluca, W. H.; Mulcahey, T. P.

    The National Battery Test Laboratory (NBTL) is an Argonne National Laboratory facility for testing, evaluating, and studying advanced electric storage batteries. The facility tests batteries developed under Department of Energy programs and from private industry. These include batteries intended for future electric vehicle (EV) propulsion, electric utility load leveling (LL), and solar energy storage. Since becoming operational, the NBTL has evaluated well over 1400 cells (generally in the form of three- to six-cell modules, but up to 140-cell batteries) of various technologies. Performance characterization assessments are conducted under a series of charge/discharge cycles with constant current, constant power, peak power, and computer simulated dynamic load profile conditions. Flexible charging algorithms are provided to accommodate the specific needs of each battery under test. Special studies are conducted to explore and optimize charge procedures, to investigate the impact of unique load demands on battery performance, and to analyze the thermal management requirements of battery systems.

  15. Ecological risk assessment at the Idaho National Engineering Laboratory: Overview

    International Nuclear Information System (INIS)

    VanHorn, R.; Bensen, T.; Green, T.; Hampton, N.; Staley, C.; Morris, R.; Brewer, R.; Peterson, S.

    1994-01-01

    The paper will present an overview of the methods and results of the screening level ecological risk assessment (ERA) performed at the Idaho National Engineering Laboratory (INEL). The INEL is a site with some distinct characteristics. First it is a large Department of Energy (DOE) laboratory (2,300 km 2 ) having experienced 40 years of nuclear material production operations. Secondly, it is a relatively undisturbed cold desert ecosystem. Neither of these issues have been sufficiently addressed in previous ERAs. It was necessary in many instances to develop methods that differed from those used in other studies. This paper should provide useful methodologies for the ERAs performed at other similar sites

  16. Research and Progress on Virtual Cloud Laboratory

    Directory of Open Access Journals (Sweden)

    Zhang Jian Wei

    2016-01-01

    Full Text Available In recent years, cloud computing technology has experienced continuous development and improvement, and has gradually expanded to the education sector. First, this paper will introduce the background knowledge of the current virtual cloud laboratory; by comparing the advantages and disadvantages between traditional laboratory and virtual cloud laboratory, and comparing the application, advantages and disadvantages, and development trend of OpenStack technology and VMWare technology in safety, performance, design, function, use case, and value of virtual cloud laboratory, this paper concludes that application based on OpenStack virtual cloud laboratory in universities and research institutes and other departments is essential.

  17. Photovoltaic module certification/laboratory accreditation criteria development

    Energy Technology Data Exchange (ETDEWEB)

    Osterwald, C.R. [National Renewable Energy Lab., Golden, CO (United States); Hammond, R.L.; Wood, B.D.; Backus, C.E.; Sears, R.L. [Arizona State Univ., Tempe, AZ (United States); Zerlaut, G.A. [SC-International Inc., Phoenix, AZ (United States); D`Aiello, R.V. [RD Associates, Tempe, AZ (United States)

    1995-04-01

    This document provides an overview of the structure and function of typical product certification/laboratory accreditation programs. The overview is followed by a model program which could serve as the basis for a photovoltaic (PV) module certification/laboratory accreditation program. The model covers quality assurance procedures for the testing laboratory and manufacturer, third-party certification and labeling, and testing requirements (performance and reliability). A 30-member Criteria Development Committee was established to guide, review, and reach a majority consensus regarding criteria for a PV certification/laboratory accreditation program. Committee members represented PV manufacturers, end users, standards and codes organizations, and testing laboratories.

  18. Remote Laboratory Collaboration Plan in Communications Engineering

    Directory of Open Access Journals (Sweden)

    Akram Ahmad Abu-aisheh

    2012-11-01

    Full Text Available Communications laboratories for electrical engineering undergraduates typically require that students perform practical experiments and document findings as part of their knowledge and skills development. Laboratory experiments are usally designed to support and reinforce theories presented in the classroom and foster independent thinking; however, the capital cost of equipment needed to sustain a viable laboratory environment is large and ongoing maintenance is an annual expense. Consequently, there is a need to identify and validate more economic solutions for engineering laboratories. This paper presents a remote laboratory collaboration plan for use in an elctrical engineering communications course.

  19. Customer satisfaction assessment at the Pacific Northwest National Laboratory; TOPICAL

    International Nuclear Information System (INIS)

    DN Anderson; ML Sours

    2000-01-01

    The Pacific Northwest National Laboratory (PNNL) is developing and implementing a customer satisfaction assessment program (CSAP) to assess the quality of research and development provided by the laboratory. This report presents the customer survey component of the PNNL CSAP. The customer survey questionnaire is composed of two major sections: Strategic Value and Project Performance. Both sections contain a set of questions that can be answered with a 5-point Likert scale response. The strategic value section consists of five questions that are designed to determine if a project directly contributes to critical future national needs. The project Performance section consists of nine questions designed to determine PNNL performance in meeting customer expectations. A statistical model for customer survey data is developed and this report discusses how to analyze the data with this model. The properties of the statistical model can be used to establish a gold standard or performance expectation for the laboratory, and then to assess progress. The gold standard is defined using laboratory management input-answers to four questions, in terms of the information obtained from the customer survey: (1) What should the average Strategic Value be for the laboratory project portfolio? (2) What Strategic Value interval should include most of the projects in the laboratory portfolio? (3) What should average Project Performance be for projects with a Strategic Value of about 2? (4) What should average Project Performance be for projects with a Strategic Value of about 4? To be able to provide meaningful answers to these questions, the PNNL customer survey will need to be fully implemented for several years, thus providing a link between management perceptions of laboratory performance and customer survey data

  20. Electromedical devices test laboratories accreditation

    International Nuclear Information System (INIS)

    Murad, C; Rubio, D; Ponce, S; Alvarez Abri, A; Terron, A; Vicencio, D; Fascioli, E

    2007-01-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University