WorldWideScience

Sample records for performance testing status

  1. Does Socioeconomic Status Explain the Relationship between Admissions Tests and Post-Secondary Academic Performance?

    Science.gov (United States)

    Sackett, Paul R.; Kuncel, Nathan R.; Arneson, Justin J.; Cooper, Sara R.; Waters, Shonna D.

    2009-01-01

    Critics of educational admissions tests assert that tests measure nothing more than socioeconomic status (SES) and that their apparent validity in predicting academic performance is an artifact of SES. The authors examined multiple large data sets containing data on admissions and related tests, SES, and grades showing that (a) SES is related to…

  2. Large block test status report

    International Nuclear Information System (INIS)

    Wilder, D.G.; Lin, W.; Blair, S.C.

    1997-01-01

    This report is intended to serve as a status report, which essentially transmits the data that have been collected to date on the Large Block Test (LBT). The analyses of data will be performed during FY98, and then a complete report will be prepared. This status report includes introductory material that is not needed merely to transmit data but is available at this time and therefore included. As such, this status report will serve as the template for the future report, and the information is thus preserved

  3. Clinical Neuropathology practice news 1-2014: Pyrosequencing meets clinical and analytical performance criteria for routine testing of MGMT promoter methylation status in glioblastoma

    Science.gov (United States)

    Preusser, Matthias; Berghoff, Anna S.; Manzl, Claudia; Filipits, Martin; Weinhäusel, Andreas; Pulverer, Walter; Dieckmann, Karin; Widhalm, Georg; Wöhrer, Adelheid; Knosp, Engelbert; Marosi, Christine; Hainfellner, Johannes A.

    2014-01-01

    Testing of the MGMT promoter methylation status in glioblastoma is relevant for clinical decision making and research applications. Two recent and independent phase III therapy trials confirmed a prognostic and predictive value of the MGMT promoter methylation status in elderly glioblastoma patients. Several methods for MGMT promoter methylation testing have been proposed, but seem to be of limited test reliability. Therefore, and also due to feasibility reasons, translation of MGMT methylation testing into routine use has been protracted so far. Pyrosequencing after prior DNA bisulfite modification has emerged as a reliable, accurate, fast and easy-to-use method for MGMT promoter methylation testing in tumor tissues (including formalin-fixed and paraffin-embedded samples). We performed an intra- and inter-laboratory ring trial which demonstrates a high analytical performance of this technique. Thus, pyrosequencing-based assessment of MGMT promoter methylation status in glioblastoma meets the criteria of high analytical test performance and can be recommended for clinical application, provided that strict quality control is performed. Our article summarizes clinical indications, practical instructions and open issues for MGMT promoter methylation testing in glioblastoma using pyrosequencing. PMID:24359605

  4. LARGE BLOCK TEST STATUS REPORT

    International Nuclear Information System (INIS)

    D.G. WILDER, W. LIN, S.C. BLAIR, T. BUSCHECK, R.C. CARLSON, K. LEE, A. MEIKE, A.L. RAMIREZ, J.L. WAGONER, AND J. WANG

    1997-01-01

    This report is intended to serve as a status report, which essentially transmits the data that have been collected to date on the Large Block Test (LBT). The analyses of data will be performed during FY98, and then a complete report will be prepared. This status report includes introductory material that is not needed merely to transmit data but is available at this time and therefore included. As such, this status report will serve as the template for the future report, and the information is thus preserved. The United States Department of Energy (DOE) is investigatinq the suitability of Yucca Mountain (YM) as a potential site for the nation's first high-level nuclear waste repository. As shown in Fig. 1-1, the site is located about 120 km northwest of Las Vegas, Nevada, in an area of uninhabited desert

  5. Current Status and Performance Tests of Korea Heat Load Test Facility KoHLT-EB

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sukkwon; Jin, Hyunggon; Shin, Kyuin; Choi, Boguen; Lee, Eohwak; Yoon, Jaesung; Lee, Dongwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Duckhoi; Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    A commissioning test has been scheduled to establish the installation and preliminary performance experiments of the copper hypervapotron mockups. And a qualification test will be performed to evaluate the CuCrZr duct liner in the ITER neutral beam injection facility and the ITER first wall small-scale mockups of the semi-prototype, at up to 1.5 and 5 MW/m{sup 2} high heat flux. Also, this system will be used to test other PFCs for ITER and materials for tokamak reactors. Korean high heat flux test facility(KoHLT-EB; Korea Heat Load Test facility - Electron Beam) by using an electron beam system has been constructed in KAERI to perform the qualification test for ITER blanket FW semi-prototype mockups, hypervapotron cooling devices in fusion devices, and other ITER plasma facing components. The commissioning and performance tests with the supplier of e-gun system have been performed on November 2012. The high heat flux test for hypervapotron cooling device and calorimetry were performed to measure the surface heat flux, the temperature profile and cooling performance. Korean high heat flux test facility for the plasma facing components of nuclear fusion machines will be constructed to evaluate the performance of each component. This facility for the plasma facing materials will be equipped with an electron beam system with a 60 kV acceleration gun.

  6. Jump test performance and sarcopenia status in men and women, 55 to 75 years of age.

    Science.gov (United States)

    Singh, Harshvardhan; Kim, Daeyeol; Kim, Eonho; Bemben, Michael G; Anderson, Mark; Seo, Dong-Il; Bemben, Debra A

    2014-01-01

    Jumping mechanography uses maximal countermovement jumps to test obtain such as jump power (JPow). Recently, it has been shown to be a safe method for assessing muscle function in older adults; however, little is known about the relationships between JPow, muscle strength, and sarcopenia status. The purpose of this study was to examine jump performance, muscle strength, and sarcopenia status in older adults. This was a cross-sectional study that included men (n = 27) and women (n = 33) (55-75 years) recruited from the general community. Participants completed health status and physical activity questionnaires. Body composition, including appendicular skeletal muscle mass (ASM), bone free lean body mass, and relative skeletal muscle mass index, were assessed by total body dual-energy x-ray absorptiometry scans. The criteria for sarcopenia were relative skeletal muscle mass index values less than 7.26 kg/m2 for men and less than 5.45 kg/m2 for women. Three vertical jumps on a jump mat were performed to assess JPow, jump velocity (JVel), and jump height (JHt). Muscle strength was measured by 1RM testing for leg press (LP) and right and left hip abduction isotonic resistance exercises. Sarcopenia was found in 20% (12/60) of the participants. Jump power was significantly lower (P = .001) in the sarcopenia group than in the normal group, 651.1 (41.7) W versus 851.0 (27.4) W, respectively. Jump power and JHt were significantly (P mass. Significant (P muscle strength (LP, right and left hip abduction). The jump test protocol was conducted safely with no injuries or balance issues. Our finding of lower JPow in sarcopenic individuals adds new information to the existing literature on age-related declines in muscle power. Community-dwelling individuals classified as sarcopenic had significantly lower JPow but not muscle strength compared with their counterparts with normal amounts of muscle mass. Jump test variables were positively correlated with lean tissue and lower body

  7. Coping style and performance status in a group of oncological inpatients

    Directory of Open Access Journals (Sweden)

    Cecilia Chau Pérez-Aranibar

    2002-06-01

    Full Text Available The associations between coping styles, measured by COPE Test, dispositional version (Carver,Scheier and Weintraub, 1989, and Health Status inferred through a performance status, measured by Karnofsky's Index of Behavioral Performance are examined. The study focuses upon 28 oncological in patients. Positive moderate Pearson's correlations were found between these two variables in this correlational-descriptive study. These were interpreted in the following sense: the larger use of the style, the less health status among the scales suppression of competent activities, procrastination of coping, instrumental social support, focusing and releasing of emotions and behavioral disengagement. The active coping scale presented a negative correlationwith regard to Performance Status as a health measure.

  8. GPS Device Testing Based on User Performance Metrics

    Science.gov (United States)

    2015-10-02

    1. Rationale for a Test Program Based on User Performance Metrics ; 2. Roberson and Associates Test Program ; 3. Status of, and Revisions to, the Roberson and Associates Test Program ; 4. Comparison of Roberson and DOT/Volpe Programs

  9. Fail or flourish? Cognitive appraisal moderates the effect of solo status on performance.

    Science.gov (United States)

    White, Judith B

    2008-09-01

    When everyone in a group shares a common social identity except one individual, the one who is different from the majority has solo status. Solo status increases one's visibility and performance pressure, which may result in stress. Stress has divergent effects on performance, and individuals' response to stressful situations is predicted by their cognitive appraisal (challenge or threat) of the situation. Two experiments test the hypothesis that cognitive appraisal moderates the effect of solo status on performance. Experiment 1 finds that at relatively high appraisal levels (resources exceed demands), solo status improves men's and women's performance; at relatively low appraisal levels, solo status hurts performance. Experiment 2 replicates this effect for solo status based on minimal group assignment. Results suggest that for individuals who feel challenged and not threatened by their work, it may help to be a solo.

  10. Mechanisms Engineering Test Loop - Phase 1 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Kultgen, D. [Argonne National Lab. (ANL), Argonne, IL (United States); Grandy, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Hvasta, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Lisowski, D. [Argonne National Lab. (ANL), Argonne, IL (United States); Toter, W. [Argonne National Lab. (ANL), Argonne, IL (United States); Borowski, A. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-09-01

    This report documents the current status of the Mechanisms Engineering Test Loop (METL) as of the end of FY2016. Currently, METL is in Phase I of its design and construction. Once operational, the METL facility will test small to intermediate-scale components and systems in order to develop advanced liquid metal technologies. Testing different components in METL is essential for the future of advanced fast reactors as it will provide invaluable performance data and reduce the risk of failures during plant operation.

  11. Block Storage Service: Status and Performance

    CERN Document Server

    Van der Ster, Daniel

    2014-01-01

    This memo summarizes the current status of the Ceph block storage service as it is used for OpenStack Cinder Volumes and Glance Images as of May 2014. We present the block storage activity on the current cluster, measuring IOPS and latencies, and present a cost/benefit analysis of using SSDs to optimize the cost and performance efficiency of the service. During tests in collaboration with IT-CF, we have concluded that by adding SSDs as the synchronous write journals (used to guarantee data durability), we are able increase the IOPS capacity by 4-5 times, at a cost of decreasing the available volume by 20%. Further, the testing has shown that the Ceph implementation is able to operate at the limit of the hardware performance; software-induced performance limitations were not yet observed in either the spinning disk or SSD configurations. In addition, we believe that increasing small write performance with SSDs is applicable only to the block storage use-case; high-bandwidth use-cases such as physics data stora...

  12. Hierarchy stability moderates the effect of status on stress and performance in humans.

    Science.gov (United States)

    Knight, Erik L; Mehta, Pranjal H

    2017-01-03

    High social status reduces stress responses in numerous species, but the stress-buffering effect of status may dissipate or even reverse during times of hierarchical instability. In an experimental test of this hypothesis, 118 participants (57.3% female) were randomly assigned to a high- or low-status position in a stable or unstable hierarchy and were then exposed to a social-evaluative stressor (a mock job interview). High status in a stable hierarchy buffered stress responses and improved interview performance, but high status in an unstable hierarchy boosted stress responses and did not lead to better performance. This general pattern of effects was observed across endocrine (cortisol and testosterone), psychological (feeling in control), and behavioral (competence, dominance, and warmth) responses to the stressor. The joint influence of status and hierarchy stability on interview performance was explained by feelings of control and testosterone reactivity. Greater feelings of control predicted enhanced interview performance, whereas increased testosterone reactivity predicted worse performance. These results provide direct causal evidence that high status confers adaptive benefits for stress reduction and performance only when the social hierarchy is stable. When the hierarchy is unstable, high status actually exacerbates stress responses.

  13. Personality characteristics and affective status related to cognitive test performance and gender in patients with memory complaints.

    Science.gov (United States)

    Vestberg, Susanna; Passant, Ulla; Risberg, Jarl; Elfgren, Christina

    2007-11-01

    The aims are to study personality characteristics of patients with memory complaints and to assess the presence of objective (OMI) versus subjective (SMI) memory impairment, the affective status, as well as potential gender differences. The patients were assessed by means of a neuropsychiatric examination and a neuropsychological test-battery. The Swedish version of the revised NEO Personality Inventory (NEO PI-R) and the Hospital Anxiety and Depression Scale (HADS) were used. The 57 patients (38 women, 19 men, mean age 56.9) differed from the Swedish normative group in three of the five personality factors: neuroticism, extraversion and agreeableness. This was mainly because of the scores of the female patients. Approximately half of the patients had OMI. No differences regarding personality factors or affective status were found between OMI and SMI patients. The female patients scored significantly higher than the male patients on symptoms of anxiety and depression. Neuroticism and symptoms of depression interacted with memory performance and gender. Our findings demonstrate the importance of applying an objective assessment of memory functions and a gender perspective when studying patients with memory complaints.

  14. Correlation Between Screening Mammography Interpretive Performance on a Test Set and Performance in Clinical Practice.

    Science.gov (United States)

    Miglioretti, Diana L; Ichikawa, Laura; Smith, Robert A; Buist, Diana S M; Carney, Patricia A; Geller, Berta; Monsees, Barbara; Onega, Tracy; Rosenberg, Robert; Sickles, Edward A; Yankaskas, Bonnie C; Kerlikowske, Karla

    2017-10-01

    Evidence is inconsistent about whether radiologists' interpretive performance on a screening mammography test set reflects their performance in clinical practice. This study aimed to estimate the correlation between test set and clinical performance and determine if the correlation is influenced by cancer prevalence or lesion difficulty in the test set. This institutional review board-approved study randomized 83 radiologists from six Breast Cancer Surveillance Consortium registries to assess one of four test sets of 109 screening mammograms each; 48 radiologists completed a fifth test set of 110 mammograms 2 years later. Test sets differed in number of cancer cases and difficulty of lesion detection. Test set sensitivity and specificity were estimated using woman-level and breast-level recall with cancer status and expert opinion as gold standards. Clinical performance was estimated using women-level recall with cancer status as the gold standard. Spearman rank correlations between test set and clinical performance with 95% confidence intervals (CI) were estimated. For test sets with fewer cancers (N = 15) that were more difficult to detect, correlations were weak to moderate for sensitivity (woman level = 0.46, 95% CI = 0.16, 0.69; breast level = 0.35, 95% CI = 0.03, 0.61) and weak for specificity (0.24, 95% CI = 0.01, 0.45) relative to expert recall. Correlations for test sets with more cancers (N = 30) were close to 0 and not statistically significant. Correlations between screening performance on a test set and performance in clinical practice are not strong. Test set performance more accurately reflects performance in clinical practice if cancer prevalence is low and lesions are challenging to detect. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  15. [ASSOCIATION BETWEEN FITNESS, NUTRITIONAL STATUS AND ACADEMIC PERFORMANCE IN PHYSICAL EDUCATION STUDENTS].

    Science.gov (United States)

    Godoy Cumillaf, Andrés; Valdés Badilla, Pablo; Fariña Herrera, Custodio; Cárcamo Mora, Francisco; Medina Herrera, Bernice; Meneses Sandoval, Elías; Gedda Muñoz, Relmu; Durán Agüero, Samuel

    2015-10-01

    several studies demonstrated that regular physical exercise would impact positively on the academic performance of students. to determine the association between physical fitness, nutritional status and academic performance of students of Pedagogy in Physical Education from Temuco, Chile. the sample was selected on a non-probabilistic approach, which included 208 subjects (n = 153 women and n = 55 women). The variables studied were physical fitness (short Abs, long jump with feet together, forward trunk flexion, elbow flexion and extension and "course navette" test), nutritional status (BMI) and academic performance (classified as up and down the academic average). 87.5% of students have a satisfactory fitness and a BMI of 23.8 ± 2.9 kg/m2. The students with the best academic performance were those with the higher proportion of satisfactory physical condition (92.5 %). No association between academic performance and nutritional status was determined, but it was observed between low fitness and a great risk of low academic performance (OR = 2.8, 95% CI 1.0 to 8 1; p academic achievement and physical fitness among students is observed, but no for the nutritional status and the academic performance. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  16. Determination of HIV Status in African Adults With Discordant HIV Rapid Tests.

    Science.gov (United States)

    Fogel, Jessica M; Piwowar-Manning, Estelle; Donohue, Kelsey; Cummings, Vanessa; Marzinke, Mark A; Clarke, William; Breaud, Autumn; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K K; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J; Eshleman, Susan H

    2015-08-01

    In resource-limited settings, HIV infection is often diagnosed using 2 rapid tests. If the results are discordant, a third tie-breaker test is often used to determine HIV status. This study characterized samples with discordant rapid tests and compared different testing strategies for determining HIV status in these cases. Samples were previously collected from 173 African adults in a population-based survey who had discordant rapid test results. Samples were classified as HIV positive or HIV negative using a rigorous testing algorithm that included two fourth-generation tests, a discriminatory test, and 2 HIV RNA tests. Tie-breaker tests were evaluated, including rapid tests (1 performed in-country), a third-generation enzyme immunoassay, and two fourth-generation tests. Selected samples were further characterized using additional assays. Twenty-nine samples (16.8%) were classified as HIV positive and 24 of those samples (82.8%) had undetectable HIV RNA. Antiretroviral drugs were detected in 1 sample. Sensitivity was 8.3%-43% for the rapid tests; 24.1% for the third-generation enzyme immunoassay; 95.8% and 96.6% for the fourth-generation tests. Specificity was lower for the fourth-generation tests than the other tests. Accuracy ranged from 79.5% to 91.3%. In this population-based survey, most HIV-infected adults with discordant rapid tests were virally suppressed without antiretroviral drugs. Use of individual assays as tie-breaker tests was not a reliable method for determining HIV status in these individuals. More extensive testing algorithms that use a fourth-generation screening test with a discriminatory test and HIV RNA test are preferable for determining HIV status in these cases.

  17. Simple prognostic model for patients with advanced cancer based on performance status.

    Science.gov (United States)

    Jang, Raymond W; Caraiscos, Valerie B; Swami, Nadia; Banerjee, Subrata; Mak, Ernie; Kaya, Ebru; Rodin, Gary; Bryson, John; Ridley, Julia Z; Le, Lisa W; Zimmermann, Camilla

    2014-09-01

    Providing survival estimates is important for decision making in oncology care. The purpose of this study was to provide survival estimates for outpatients with advanced cancer, using the Eastern Cooperative Oncology Group (ECOG), Palliative Performance Scale (PPS), and Karnofsky Performance Status (KPS) scales, and to compare their ability to predict survival. ECOG, PPS, and KPS were completed by physicians for each new patient attending the Princess Margaret Cancer Centre outpatient Oncology Palliative Care Clinic (OPCC) from April 2007 to February 2010. Survival analysis was performed using the Kaplan-Meier method. The log-rank test for trend was employed to test for differences in survival curves for each level of performance status (PS), and the concordance index (C-statistic) was used to test the predictive discriminatory ability of each PS measure. Measures were completed for 1,655 patients. PS delineated survival well for all three scales according to the log-rank test for trend (P statistic was similar for all three scales and ranged from 0.63 to 0.64. We present a simple tool that uses PS alone to prognosticate in advanced cancer, and has similar discriminatory ability to more complex models. Copyright © 2014 by American Society of Clinical Oncology.

  18. Mild Cognitive Impairment Status and Mobility Performance

    DEFF Research Database (Denmark)

    Pedersen, Mette; Holt, Nicole E; Grande, Laura

    2014-01-01

    : An analysis was conducted on baseline data from the Boston Rehabilitative Impairment Study in the Elderly study, a cohort study of 430 primary care patients aged 65 or older. Neuropsychological tests identified participants with MCI and further subclassified those with impairment in memory domains (a......BACKGROUND: The prevalence of mild cognitive impairment (MCI) and mobility limitations is high among older adults. The aim of this study was to investigate the association between MCI status and both performance-based and self-report measures of mobility in community-dwelling older adults. METHODS...

  19. Test planning and performance

    International Nuclear Information System (INIS)

    Zola, Maurizio

    2001-01-01

    Testing plan should include Safety guide Q4 - Inspection and testing - A testing plan should be prepared including following information: General information (facility name, item or system reference, procurement document reference, document reference number and status, associated procedures and drawings); A sequential listing of all testing activities; Procedure, work instruction, specification or standard to be followed in respect of each operation and test; Acceptance criteria; Identification of who is performing tests; Identification of hold points; Type of records to be prepared for each test; Persons and organizations having authority for final acceptance. Proposed activities sequence is: visual, electrical and mechanical checks; environmental tests (thermal aging, vibrations aging, radioactive aging); performance evaluation in extreme conditions; dynamic tests with functional checks; final electrical and mechanical checks The planning of the tests should always be performed taking into account an interpretative model: a very tight cooperation is advisable between experimental people and numerical people dealing with the analysis of more or less complex models for the seismic assessment of structures and components. Preparatory phase should include the choice of the following items should be agreed upon with the final user of the tests: Excitation points, Excitation types, Excitation amplitude with respect to frequency, Measuring points. Data acquisition, recording and storage, should take into account the characteristics of the successive data processing: to much data can be cumbersome to be processed, but to few data can make unusable the experimental results. The parameters for time history acquisition should be chosen taking into account data processing: for Shock Response Spectrum calculation some special requirements should be met: frequency bounded signal, high frequency sampling, shock noise. For stationary random-like excitation, the sample length

  20. Cardiorespiratory fitness and academic performance association is mediated by weight status in adolescents: DADOS study.

    Science.gov (United States)

    Beltran-Valls, María Reyes; Adelantado-Renau, Mireia; Castro-Piñero, Jose; Sánchez-López, Mairena; Moliner-Urdiales, Diego

    2018-04-28

    The aim of our study was to examine the mediation effect of weight status on the association between cardiorespiratory fitness (CRF) and academic performance (AP). Two hundred sixty-nine adolescents (140 boys) aged 13.9 ± 0.3 years old from the DADOS study were included in this cross-sectional analysis. CRF was assessed by the 20-m shuttle run test and estimated maximum oxygen uptake was used in the analysis. AP was assessed through the final academic grades and the Science Research Associates Test of Educational Abilities for assessing reasoning, verbal, and numeric abilities. Weight status was assessed by body mass index (kg/m 2 ). Boot-strapped mediation procedures were performed and indirect effects (IE) with confidence intervals (CI) not including zero were considered statistically significant. Mediation analysis revealed that weight status acted as a mediator of the relationship of CRF with reasoning ability (IE = 0.039; CI = 0.001; 0.091) and the final grades in Math (IE = 0.011; CI = 0.002; 0.025), Language (IE = 0.013; CI = 0.004; 0.027), and GPA (IE = 0.011; CI = 0.003; 0.023). Our data show that the influence of CRF on academic performance is mediated by weight status in adolescents. We suggest that our data could be considered by educators, families, and policy makers, so that active lifestyles might be promoted when designing programs aimed to improve AP among adolescents. What is Known: • Academic performance is associated with both, cardiorespiratory fitness and weight status. • The role of weight status in the association between cardiorespiratory fitness and academic performance is poorly understood. What is New: • We support the scarce research investigating the mediating role of weight status as mechanism in the association between fitness and academic performance in youth. • Previous knowledge is expanded by suggesting that cardiorespiratory fitness is related to weight status which in turn may

  1. Status and Performance of University Librarians in Uganda ...

    African Journals Online (AJOL)

    It was also found that the status of university librarians is a significant predictor of their performance. Therefore, the paper urges university administrators in the country to re-examine the status accorded to their librarians because it is an important ingredient in their performance. Keywords: Library management; Performance ...

  2. Effects of nutritional and psychological status of the patients with advanced stomach cancer on physical performance status.

    Science.gov (United States)

    Tian, Jun; Chen, Zhen-chun; Hang, Li-Fang

    2009-10-01

    The aim of this study was to assess the associations between coping mode, nutritional status, and psychological status and performance status of the patients with advanced stomach cancer. An epidemiological survey was conducted among 233 patients with advanced stomach cancer in Fujian, China. In-person interviews were performed for the participants with respect to information of psychological status prior to chemotherapy, nutritional status during chemotherapy, and physical performance status after chemotherapy. Multivariate logistic regression analyses showed that the level of hemoglobin (HB), level of daily calorie intake, score of Depression Status Inventory (DSI), and score of confrontation subscale of Medical Coping Modes Questionnaire had a significant influence on performance status (P or =40 versus DSI score confrontation versus high score of confrontation, respectively. Depression, low score of "Confrontation", low levels of HB, and low level of daily calorie intake may be the risk factors of poor performance status of the patients with advanced stomach cancer.

  3. The ATLAS liquid argon calorimeter--status and expected performance

    International Nuclear Information System (INIS)

    Schacht, Peter

    2004-01-01

    For the ATLAS detector at the LHC, the liquid argon technique is exploited for the electromagnetic calorimetry in the central part and for the electromagnetic and hadronic calorimetry in the forward and backward regions. The construction of the calorimeter is well advanced with full cold tests of the barrel calorimeter and first endcap calorimeter only months away. The status of the project is discussed as well as the related results from beam test studies of the various calorimeter subdetectors. The results show that the expected performance meets the ATLAS requirements as specified in the ATLAS Technical Design Report

  4. Improved iodine status is associated with improved mental performance of schoolchildren in Benin.

    Science.gov (United States)

    van den Briel, T; West, C E; Bleichrodt, N; van de Vijver, F J; Ategbo, E A; Hautvast, J G

    2000-11-01

    An adequate iodine supply in utero and shortly after birth is known to be crucial to an individual's physical and mental development. The question of whether iodine supplementation later in life can exert a favorable influence on the mental performance of iodine-deficient populations was addressed in various studies, but with contradictory results. The aim of this study was to examine the effect of an improvement in iodine status on mental and psychomotor performance of schoolchildren (7-11 y) who were moderately to severely iodine deficient. The study, which was originally planned as a double-blind, randomized, placebo-controlled intervention, was carried out in an iodine-deficient population of schoolchildren (n = 196) in northern Benin. As the population began to have access to iodized salt during the 1-y intervention period, the study population was split post hoc-on the basis of urinary iodine concentrations-into a group with improved iodine status and a group with unchanged iodine status. Changes in mental and psychomotor performance over the intervention period were compared. Children with increased urinary iodine concentrations had a significantly greater increase in performance on the combination of mental tests than did the group with no change in urinary iodine concentrations. An improvement in iodine status, rather than iodine status itself, determined mental performance in this population, which was initially iodine deficient. These findings suggest a "catch-up" effect in terms of mental performance.

  5. The Mirror Fusion Test Facility cryogenic system: Performance, management approach, and present equipment status

    International Nuclear Information System (INIS)

    Slack, D.S.; Chronis, W.C.

    1987-01-01

    The cryogenic system for the Mirror Fusion Test Facility (MFTF) is a 14-kW, 4.35-K helium refrigeration system that proved to be highly successful and cost-effective. All operating objectives were met, while remaining within a few percent of initial cost and schedule plans. The management approach used in MFTF allowed decisions to be made quickly and effectively, and it helped keep costs down. Manpower levels, extent and type of industrial participation, key aspects of subcontractor specifications, and subcontractor interactions are reviewed, as well as highlights of the system tests, operation, and present equipment status. Organizations planning large, high-technology systems may benefit from this experience with the MFTF cryogenic system

  6. Neurovirulence safety testing of mumps vaccines--historical perspective and current status.

    Science.gov (United States)

    Rubin, S A; Afzal, M A

    2011-04-05

    Many live, attenuated viral vaccines are derived from wild type viruses with known neurovirulent properties. To assure the absence of residual neurotoxicity, pre-clinical neurovirulence safety testing of candidate vaccines is performed. For mumps virus, a highly neurotropic virus, neurovirulence safety testing is performed in monkeys. However, laboratory studies suggest an inability of this test to correctly discern among virus strains of varying neurovirulence potential in man, and, further, some vaccines found to be neuroattenuated in monkeys were later found to be neurovirulent in humans when administered in large numbers. Over the past decade, concerted efforts have been made to replace monkey-based neurovirulence safety testing with more informative, alternative methods. This review summarizes the current status of mumps vaccine neurovirulence safety testing and insights into models currently approved and those under development. Published by Elsevier Ltd.

  7. Software development for simplified performance tests and weekly performance check in Younggwang NPP Unit 3 and 4

    International Nuclear Information System (INIS)

    Hur, K. Y.; Jang, S. H.; Lee, J. W.; Kim, J. T.; Park, J. C.

    2002-01-01

    This paper covers the current status of turbine cycle performance test in nuclear power plants and the software development which can solve some shortcomings related to performance tests. The software developed is for simplified performance tests and weekly performance checks in Yonggwang nuclear power plant unit 3 and 4. This software includes the requirements from the efficiency division for the consistency with actual performance analysis work and the usability of the collected performance test data. From the working survey, we identify the difference between the embedded performance analysis modules and the actual performance analysis work. This software helps operation or maintenance personnel to reduce work load, to support the trend analysis of essential parameters in a turbine cycle, and to utilize the correction curves for the decision-making in their work

  8. Oxidative and antioxidative status in the testes of rats with acute epididymitis.

    Science.gov (United States)

    Kaya, Mete; Boleken, Mehmet Emin; Zeyrek, Fadile; Ozardali, Ilyas; Kanmaz, Turan; Erel, Ozcan; Yücesan, Selçuk

    2006-01-01

    Epididymitis is an inflammation or infection of the epididymis, a convoluted duct that lies on the posterior surface of the testicle. Oxidative stress due to excessive production of reactive oxygen species in epididymitis, impaired antioxidant defense mechanisms, or both, precipitates a range of pathologies that are currently believed to negatively affect the male reproductive function. How oxidative stress affects the testes is still unknown. We aimed to investigate the oxidative and antioxidative status of testes of rats with unilateral acute Escherichia coli epididymitis. The study included 36 male Wistar albino rats which were divided into three groups. In the epididymitis group (n = 12), an E. coli suspension was injected into the right ductus deferens of rats, and the same amount of saline was injected in the saline groups (n = 12). No surgery was performed in the control group (n = 12) for baseline values. Rats were sacrificed after 24 h and the epididymis and testes removed. The infection was confirmed by histopathologic evaluation and microbiological tests. The oxidative status of testes was evaluated by measuring myeloperoxidase (MPO) activity, and antioxidative status was evaluated by measuring total antioxidant response (TAR) and total antioxidant capacity levels (TAC). MPO activity in both the ipsilateral and contralateral testes of the epididymitis group was significantly higher than those of the saline and control groups (p antioxidants. 2006 S. Karger AG, Basel.

  9. Current status of accreditation for drug testing in hair.

    Science.gov (United States)

    Cooper, Gail; Moeller, Manfred; Kronstrand, Robert

    2008-03-21

    At the annual meeting of the Society of Hair Testing in Vadstena, Sweden in 2006, a committee was appointed to address the issue of guidelines for hair testing and to assess the current status of accreditation amongst laboratories offering drug testing in hair. A short questionnaire was circulated amongst the membership and interested parties. Fifty-two responses were received from hair testing laboratories providing details on the amount and type of hair tests they offered and the status of accreditation within their facilities. Although the vast majority of laboratories follow current guidelines (83%), only nine laboratories were accredited to ISO/IEC 17025 for hair testing. A significant number of laboratories reporting that they were in the process of developing quality systems with a view to accrediting their methods within 2-3 years. This study provides an insight into the status of accreditation in hair testing laboratories and supports the need for guidelines to encourage best practice.

  10. Status of RBCB testing of LMR oxide fuel in EBR-II

    International Nuclear Information System (INIS)

    Strain, R.V.; Bottcher, J.H.; Gross, K.C.; Lambert, J.D.B.; Ukai, S.; Nomura, S.; Shikakura, S.; Katsuragawa, M.

    1991-01-01

    The status is given of the the American-Japanese collaborative program in Experimental Breeder Reactor 2 to determine the run-beyond-cladding-breach performance of (UPu)O 2 fuel pins for liquid-metal cooled reactors. Phase 1 of the collaboration involved eighteen irradiation tests over 1981--86 with 5.84-mm pins in 316 or D9 stainless steel. Emphasis in Phase 2 tests from 1989 onwards is with larger diameter (7.5mm) pins in advanced claddings. Results include delayed neutron and fission gas release data from breached pins, the impact of fuel-sodium reaction product formation on pin performance, and fuel and fission product contamination from failures. 13 refs, 1 fig., 4 tabs

  11. What effects performance status of patients with hepatocellular carcinoma: stage of tumor versus underlying liver status

    International Nuclear Information System (INIS)

    Sarwar, S.; Tarique, S.

    2015-01-01

    Objective: To identify variables associated with poor performance status of hepatocellular carcinoma (HCC) patients and to compare impact of stage of liver disease and that of hepatoma on functional status of patient. Patients and Methods: We included 254 confirmed cases of liver cancer in a crosssectional analytical study carried out at Doctors Hospital Lahore. Patient's clinical, biochemical and radiological variables were correlated with Karnofsky's performance status (KPS) using pearson correlation. Model for End stage Liver Disease (MELD) and Cancer of Liver Italian Program (CLIP) were evaluated for predicting performance status using Receiver Operating Characteristic (ROC) curve. Results: Mean age of patients was 56.69 (±10.34) and male to female ratio was 2.47: 1 (181/73). On KPS evaluation 84 (33.1%) patients scored between 80-100, 147 (57.9%) had score of 50-70 while in 23 (9.1%) KPS score was between 0-40. Variables associated with poor performance status were bilirubin> 3mg/dl (p value 0.00), albumin< 2.5 g/dl (p value 0.00), creatinine > 1.2mg/dl (p 0.00), prothrombin time> 16seconds (p value 0.00), size of tumor >7cm (p value 0.02), tumor involving > 50% of liver mass (p value 0.00) and vascular invasion (p value 0.00). Both stage of liver disease as determined by MELD and stage of liver cancer as per CLIP scores had strong correlation (p value 0.00) with poor performance status of patient. Area under ROC curve was 0.764 for MELD score and 0.785 for CLIP score. Conclusion: Performance status of liver cancer patients is affected by both stage of liver disease and that of liver tumor. Patients with MELD score above 16 and CLIP score above 4 have poor performance status. (author)

  12. Performance testing of the finance platform based on LoadRunner

    Directory of Open Access Journals (Sweden)

    CHEN Mengyun

    2016-08-01

    Full Text Available In this paper,a performance testing scheme is designed to test the software interface of the financial management platform based on LoadRunner,and the scheme has been used for the performance testing of the interactive interface of the financial management platform of Shanghai Zuo Hao Network Technology Co.Ltd.The result shows that the performance characteristics of the system interface are different under different scenarios,and TPS and CPU usage performance characteristics are in an optimal status when the number of concurrent users is 40,while CPU becomes the bottleneck which is need to be addressed by system when the number of concurrent users is 50.At last,the effectiveness of the scheme has been proved.

  13. Enhancing HIV status disclosure and partners' testing through ...

    African Journals Online (AJOL)

    Background: In Tanzania HIV Testing and Counselling (HTC) is being implemented through voluntary counselling and testing (VCT), provider initiated counselling and testing (PITC) and work place counselling and testing (HTC). Within these programmes, HIV status disclosure is emphasized. However, among persons who ...

  14. Latest status of the Japanese LCT coil and the domestic test facility

    International Nuclear Information System (INIS)

    Shimamoto, S.; Ando, T.; Hiyama, T.

    1981-01-01

    The Japan Atomic Energy Research Institute (JAERI), representing Japan, is now making one of six test coils for the International Energy Agency's (IEA) Large Coil Task(LCT). The Japanese LCT coil, which has a stored energy of 120 MJ, is based on a NgTi conductor, is pool-cooled, has a maximum field of 8T, and is edgewise, double-pancake wound, was completed in October, 1981. The LCT coil will be tested in the newly constructed domestic test facility up to its rated current in November, 1981, before transportation ORNL. The domestic test facility, which is composed of a cryogenic system a vacuum system, a power supply with protection system, and a data acqusition and control system, was completed and its performance measured at a new building for the LCT test at JSAERI in June, 1981. This paper describes the latest construction status of the Japanese LCT coil and the domestic test facility. The performance of the domestic test facility is described in this paper

  15. E-4 Test Facility Design Status

    Science.gov (United States)

    Ryan, Harry; Canady, Randy; Sewell, Dale; Rahman, Shamim; Gilbrech, Rick

    2001-01-01

    Combined-cycle propulsion technology is a strong candidate for meeting NASA space transportation goals. Extensive ground testing of integrated air-breathing/rocket system (e.g., components, subsystems and engine systems) across all propulsion operational modes (e.g., ramjet, scramjet) will be needed to demonstrate this propulsion technology. Ground testing will occur at various test centers based on each center's expertise. Testing at the NASA John C. Stennis Space Center will be primarily concentrated on combined-cycle power pack and engine systems at sea level conditions at a dedicated test facility, E-4. This paper highlights the status of the SSC E-4 test Facility design.

  16. Status of development and irradiation performance of advanced proliferation resistant MTR fuel at NUKEM

    International Nuclear Information System (INIS)

    Hrovat, M.; Hassel, H.-W.; Wehner, E.

    1985-01-01

    This paper describes the current status of development and irradiation performance of fuel elements for Material Test and Research (MTR) Reactors with Medium Enriched Uranium (MEU, ≤ 45 % 235-U) and Low Enriched Uranium (LEU, ≤ 20 % 235-U). (author)

  17. Performance testing of medical US equipment using US phantom (ATS-539)

    International Nuclear Information System (INIS)

    Kim, Do Hyung; Kwon, Deok Moon

    2014-01-01

    This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment

  18. Performance testing of medical US equipment using US phantom (ATS-539)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Hyung [Daegu Branch, Korea Association of Health Promotion, Daegu (Korea, Republic of); Kwon, Deok Moon [Dept. of Radiology, Daegu Health College, Daegu (Korea, Republic of)

    2014-12-15

    This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment.

  19. The NIRspec assembly integration and test status

    Science.gov (United States)

    Wettemann, Thomas; Ehrenwinkler, Ralf; Johnson, Thomas E.; Maschmann, Marc; Mosner, Peter; te Plate, Maurice; Rödel, Andreas

    2017-11-01

    The Near-Infrared Spectrograph (NIRSpec) is one of the four instruments on the James Webb Space Telescope (JWST) scheduled for launch in 2018. NIRSpec has been manufactured and tested by an European industrial consortium led by Airbus Defence and Space and delivered to the European Space Agency (ESA) and NASA in September 2013. Since then it has successfully been integrated into the JWST Integrated Science Instrument Module (ISIM) and is currently in ISIM Cryo-Vacuum Test#2. Since however two of its most important assemblies, the Focal Plane Assembly (FPA) and the Micro-Shutter Assembly (MSA) need to be replaced by new units we will present the status of the instrument, the status of its new flight assemblies in manufacturing and testing and give an outlook on the planned exchange activities and the following instrument re-verification.

  20. Direct and indirect relationships of physical fitness, weight status, and learning duration to academic performance in Japanese schoolchildren.

    Science.gov (United States)

    Ishihara, Toru; Morita, Noriteru; Nakajima, Toshihiro; Okita, Koichi; Yamatsu, Koji; Sagawa, Masato

    2018-03-01

    The purpose of this study was to determine, using structural equation modelling (SEM), the direct and indirect influence of daily behaviours (i.e. exercise/learning durations), weight status, and physical fitness on academic performance among seventh-grade schoolchildren, after controlling for socioeconomic status. We analysed cross-sectional data from 274 schoolchildren (159 males and 115 females; 12-13 years old). Academic performance was assessed using the total grade points in eight academic subjects. Physical fitness was evaluated using the total score of eight physical fitness tests and weight status using body mass index. The daily behaviours and socioeconomic status were assessed by the questionnaire. The SEM showed an adequate fit to the data (χ 2  = 0.684, p = .710, RMSEA = .000). Physical fitness and learning durations had direct effects on academic performance (β = .301, p academic performance via physical fitness. These findings suggest that, independent of socioeconomic status and learning durations, exercise habits and maintaining healthy weight status may indirectly contribute to academic success via better physical fitness in children.

  1. Solo status and self-construal: being distinctive influences racial self-construal and performance apprehension in African American women.

    Science.gov (United States)

    Sekaquaptewa, Denise; Waldman, Andrew; Thompson, Mischa

    2007-10-01

    A preliminary study and main experiment tested the hypothesis that racial solo status (being the only member of one's race in a group) increases racial self-construal among African Americans. The preliminary study showed that African American men and women reported greater collectivist (i.e., group-based) over individualist self-construal under solo compared to nonsolo status, whereas Whites did not. The main experiment showed that the increased collectivism among African American solo women appears to be strongly reflected in racial identity becoming a salient aspect of self-construal. African American participants were also more likely than Whites to perceive that their anticipated performance would be generalized to their race, to feel like representatives of their race, and to show greater performance apprehension (indirectly evidenced by increased self-handicapping) when in racial solo status. The implications of solo status for African Americans in evaluative situations (such as academic testing sessions) are discussed. 2007 APA

  2. Stunting, poor iron status and parasite infection are significant risk factors for lower cognitive performance in Cambodian school-aged children.

    Directory of Open Access Journals (Sweden)

    Marlene Perignon

    Full Text Available BACKGROUND: Nutrition is one of many factors affecting the cognitive development of children. In Cambodia, 55% of children <5 y were anemic and 40% stunted in 2010. Currently, no data exists on the nutritional status of Cambodian school-aged children, or on how malnutrition potentially affects their cognitive development. OBJECTIVE: To assess the anthropometric and micronutrient status (iron, vitamin A, zinc, iodine of Cambodian schoolchildren and their associations with cognitive performance. METHODS: School children aged 6-16 y (n = 2443 from 20 primary schools in Cambodia were recruited. Anthropometry, hemoglobin, serum ferritin, transferrin receptors, retinol-binding protein and zinc concentrations, inflammation status, urinary iodine concentration and parasite infection were measured. Socio-economic data were collected in a sub-group of children (n = 616. Cognitive performance was assessed using Raven's Colored Progressive Matrices (RCPM and block design and picture completion, two standardized tests from the Wechsler Intelligence Scale for Children (WISC-III. RESULTS: The prevalence of anemia, iron, zinc, iodine and vitamin A deficiency were 15.7%; 51.2%, 92.8%, 17.3% and 0.7% respectively. The prevalence of stunting was 40.0%, including 10.9% of severe stunting. Stunted children scored significantly lower than non-stunted children on all tests. In RCPM test, boys with iron-deficiency anemia had lower scores than boys with normal iron status (-1.46, p<0.05. In picture completion test, children with normal iron status tended to score higher than iron-deficient children with anemia (-0.81; p = 0.067 or without anemia (-0.49; p = 0.064. Parasite infection was associated with an increase in risk of scoring below the median value in block design test (OR = 1.62; p<0.05, and with lower scores in other tests, for girls only (both p<0.05. CONCLUSION: Poor cognitive performance of Cambodian school-children was multifactorial and

  3. The effects of individual status and group performance on network ties among teammates in the National Basketball Association.

    Directory of Open Access Journals (Sweden)

    Jeremy Koster

    Full Text Available For individuals, status is derived both from their personal attributes and the groups with whom they are affiliated. Depending on the performance of their groups, the status of individuals may benefit or suffer from identifying closely with the group. When the group excels, high-status members potentially receive much of the credit and increased status. Conversely, high-status members of underperforming groups potentially suffer disproportionate declines in their status relative to the low-status group members. We therefore predict an interaction between group performance and individual status on the willingness to associate with the group and its members. We test our prediction by examining social media ties among teammates in the National Basketball Association. Specifically, we investigate the "following" ties of teammates on Twitter at the end of the 2014-2015 season. Elections to All-Star games are used to measure the status of players, and team performance is measured by recent success in the postseason playoffs. The results show that compared to high-status players on successful teams, high-status players on underperforming teams are less likely to follow their teammates. This result aligns with research on status inconsistency, suggesting that individuals deemphasize their group affiliation when it jeopardizes their individual status. An additional contribution is the advancement of the probit Social Relations Model for the analysis of binary ties in social networks.

  4. The effects of individual status and group performance on network ties among teammates in the National Basketball Association.

    Science.gov (United States)

    Koster, Jeremy; Aven, Brandy

    2018-01-01

    For individuals, status is derived both from their personal attributes and the groups with whom they are affiliated. Depending on the performance of their groups, the status of individuals may benefit or suffer from identifying closely with the group. When the group excels, high-status members potentially receive much of the credit and increased status. Conversely, high-status members of underperforming groups potentially suffer disproportionate declines in their status relative to the low-status group members. We therefore predict an interaction between group performance and individual status on the willingness to associate with the group and its members. We test our prediction by examining social media ties among teammates in the National Basketball Association. Specifically, we investigate the "following" ties of teammates on Twitter at the end of the 2014-2015 season. Elections to All-Star games are used to measure the status of players, and team performance is measured by recent success in the postseason playoffs. The results show that compared to high-status players on successful teams, high-status players on underperforming teams are less likely to follow their teammates. This result aligns with research on status inconsistency, suggesting that individuals deemphasize their group affiliation when it jeopardizes their individual status. An additional contribution is the advancement of the probit Social Relations Model for the analysis of binary ties in social networks.

  5. Motivational deficits and cognitive test performance in schizophrenia.

    Science.gov (United States)

    Fervaha, Gagan; Zakzanis, Konstantine K; Foussias, George; Graff-Guerrero, Ariel; Agid, Ofer; Remington, Gary

    2014-09-01

    Motivational and cognitive deficits are core features of schizophrenia, both closely linked with functional outcomes. Although poor effort and decreased motivation are known to affect performance on cognitive tests, the extent of this relationship is unclear in patients with schizophrenia. To evaluate the association between intrinsic motivation and cognitive test performance in patients with schizophrenia. Cross-sectional and 6-month prospective follow-up study performed at 57 sites in the United States, including academic and community medical treatment centers, participating in the Clinical Antipsychotic Trials of Intervention Effectiveness study. The primary sample included 431 stable patients with a DSM-IV diagnosis of schizophrenia currently receiving a stable medication regimen. Cognitive performance and intrinsic motivation were evaluated using a comprehensive neuropsychological test battery and a derived measure from the Heinrichs-Carpenter Quality of Life Scale, respectively. Symptom severity and functional status were also assessed. The primary outcome variable was global neurocognition. Individual domains of cognition were also evaluated for their association with motivation. Level of intrinsic motivation was significantly and positively correlated with global cognitive test performance, a relationship that held for each domain of cognition evaluated (correlation range, 0.20-0.34; P motivation and cognitive performance also remained significant after controlling for antipsychotic dose (P motivation during the 6-month follow-up was also found to be significantly related to improvement in global cognitive performance (P motivation and cognitive performance and suggest that test performance is not purely a measure of ability. Future studies assessing cognition in patients with schizophrenia should consider potential moderating variables such as effort and motivation. Implications for the assessment and interpretation of cognitive impairment based on

  6. Predictive testing of performance of metals in HTR service environments

    International Nuclear Information System (INIS)

    Kondo, T.; Shindo, M.; Tamura, M.; Tsuji, H.; Kurata, Y.; Tsukada, T.

    1982-01-01

    Status of the material testing in simulated HTGR environment is reviewed with special attention focused on the methodology of the prediction of performance in long time. Importance of controlling effective chemical potentials relations in the material-environmental interface is stressed in regard of the complex inter-dependent kinetic relation between oxidation and carbon transport. Based on the recent experimental observations, proposals are made to establish some procedures for conservative prediction of the metal performance

  7. Correlation between nutritional status and comprehensive physical performance measures among older adults with undernourishment in residential institutions

    Directory of Open Access Journals (Sweden)

    Singh DKA

    2014-08-01

    Full Text Available Devinder KA Singh,1 Zahara A Manaf,2 Noor Aini M Yusoff,3 Nur A Muhammad,2 Mei Fang Phan,1 Suzana Shahar2 1Physiotherapy Program, School of Rehabilitation Sciences, 2Nutrition and Dietetics Program, School of Health Care Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur, 3ASIA Metropolitan University, Cheras, Malaysia Purpose: The consequences of combined undernourishment and decreased physical ­performance in older adults are debilitating and increases cost of care. To date, the information regarding the association between nutritional status and physical performance does not provide a complete picture. Most studies used limited or self-reported measures to evaluate physical performance. The objective of this study was to examine the correlation between nutritional status and comprehensive physical performance measures among undernourished older adults who reside in residential institutions.Methods: Forty-seven older adults (26 males, 21 females aged ≥60 (69.23±8.63 years who were identified as undernourished from two residential institutions participated in this study. A battery of physical performance tests (10 m gait speed test, dominant hand grip strength test, timed five-repetition sit-to-stand test, ten step test, arm curl test, scratch test, and respiratory muscle strength test, biochemical profiles (serum albumin, hemoglobin, serum ferritin, and prealbumin levels, and falls risk using the short-form Physiological Profile Approach were performed. The Functional Ability Questionnaire and Geriatric Depression Scale were also administered.Results: The results demonstrated that generally older adults with undernourishment scored poorly on the physical performance tests, had depression, and a high risk of falls. Biochemical results demonstrated that 10.9% of the participants were anemic, 63% had hypoalbuminemia (<3.5 g/dL, and 21.7% were at risk of protein energy malnutrition with prealbumin level (100–170 mg/L. A significant

  8. Status of the flora and fauna on the Nevada Test Site, 1992

    International Nuclear Information System (INIS)

    Hunter, R.B.

    1994-03-01

    This report documents changes in the populations of plants and animals on the Nevada Test Site (NTS) for calendar year 1992. It is part of a Department of Energy (DOE) program (Basic Environmental Compliance and Monitoring Program -- BECAMP) that also includes monitoring DOE compliance with the Endangered Species Act, the Historic Preservation Act, and the American Indian Freedom of Religion Act. Ecological studies were to comply with the National Environmental Policy Act and DOE Order 5400.1, ''General Environmental Protection Program.'' These studies focused on the following: status of ephemeral plants on the Nevada Test Site, 1992; status of reptile and amphibian populations on the Nevada Test Site, 1992; trends in small mammal populations on the Nevada Test Site, 1992; status of large mammals and birds at Nevada Test Site, 1992; and status of perennial plants on the Nevada Test Site, 1992

  9. Smoking status and cognitive performance among vocational school students in Beijing, China.

    Science.gov (United States)

    Hu, Pengjuan; Huang, Lili; Zhou, Shuang; Shi, Qiang; Xiao, Dan; Wang, Chen

    2018-02-01

    In countries where smoking is associated with lower socioeconomic status, smokers tend to perform worse on cognitive tasks than non-smokers. China is now undergoing a similar process with a recent study showing that there is a reduced cognitive performance in middle aged but not in elderly smokers. We examined the links between smoking status and cognitive functioning among vocational school students in Beijing, China. A total of 213 students aged 16-20 (98 smokers and 115 non-smokers) were recruited from three vocational schools in Beijing. Participants completed three subtests of Wechsler Adult Intelligence Scale (WAIS) (information, arithmetic, digit span) and Dysexecutive Questionnaire (DEX). Smokers also completed a cigarette smoking questionnaire and Fagerstrom Test of Nicotine Dependence (FTND). Smokers performed worse than non-smokers in tests of arithmetic and digit span forward (t = 4.25, 2.05, both P < .05). Scores on digit span backward did not differentiate smokers and non-smokers, but among smokers, the performance on this subtest was related to the age of starting smoking (r = 0.26, p < .001). Cognitive performance in smokers was not related to tobacco dependence or intensity of smoking. Compared to non-smokers, smokers had a higher total DEX score and higher scores on three of its five subscales (Inhibition, Knowing-doing dissociation and Social regulation, all p < .05). Another subscale, In-resistance, did not differentiate smokers and non-smokers, but differentiated smokers with lower and higher levels of nicotine dependence (t = -2.12, p < .05). Smokers performed worse on some cognitive tasks than non-smokers and scored higher on a questionnaire assessing executive dysfunction. Copyright © 2017. Published by Elsevier Ltd.

  10. Performance testing of dosimetry processors, status of NRC rulemaking for improved personnel dosimetry processing, and some beta dosimetry and instrumentation problems observed by NRC regional inspectors

    International Nuclear Information System (INIS)

    Dennis, N.A.; Kinneman, J.D.; Costello, F.M.; White, J.R.; Nimitz, R.L.

    1983-01-01

    Early dosimetry processor performance studies conducted between 1967 and 1979 by several different investigators indicated that a significant percentage of personnel dosimetry processors may not be performing with a reasonable degree of accuracy. Results of voluntary performance testing of US personnel dosimetry processors against the final Health Physics Society Standard, Criteria for Testing Personnel Dosimetry Performance by the University of Michigan for the Nuclear Regulatory Commission (NRC) will be summarized with emphasis on processor performance in radiation categories involving beta particles and beta particles and photon mixtures. The current status of the NRC's regulatory program for improved personnel dosimetry processing will be reviewed. The NRC is proposing amendments to its regulations, 10 CFR Part 20, that would require its licensees to utilize specified personnel dosimetry services from processors accredited by the National Voluntary Laboratory Accreditation Program of the National Bureau of Standards. Details of the development and schedule for implementation of the program will be highlighted. Finally, selected beta dosimetry and beta instrumentation problems observed by NRC Regional Staff during inspections of NRC licensed facilities will be discussed

  11. Understanding protocol performance: impact of test performance.

    Science.gov (United States)

    Turner, Robert G

    2013-01-01

    This is the second of two articles that examine the factors that determine protocol performance. The objective of these articles is to provide a general understanding of protocol performance that can be used to estimate performance, establish limits on performance, decide if a protocol is justified, and ultimately select a protocol. The first article was concerned with protocol criterion and test correlation. It demonstrated the advantages and disadvantages of different criterion when all tests had the same performance. It also examined the impact of increasing test correlation on protocol performance and the characteristics of the different criteria. To examine the impact on protocol performance when individual tests in a protocol have different performance. This is evaluated for different criteria and test correlations. The results of the two articles are combined and summarized. A mathematical model is used to calculate protocol performance for different protocol criteria and test correlations when there are small to large variations in the performance of individual tests in the protocol. The performance of the individual tests that make up a protocol has a significant impact on the performance of the protocol. As expected, the better the performance of the individual tests, the better the performance of the protocol. Many of the characteristics of the different criteria are relatively independent of the variation in the performance of the individual tests. However, increasing test variation degrades some criteria advantages and causes a new disadvantage to appear. This negative impact increases as test variation increases and as more tests are added to the protocol. Best protocol performance is obtained when individual tests are uncorrelated and have the same performance. In general, the greater the variation in the performance of tests in the protocol, the more detrimental this variation is to protocol performance. Since this negative impact is increased as

  12. Changes in performance status of elderly patients after radiotherapy

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Inoue, Takehiro; Yoshida, Ken

    2001-01-01

    The purpose of this study was to examine the feasibility of external radiation therapy for patients 80 years old and older. We analyzed changes in the performance status (PS) of 1353 patients by external radiotherapy at Osaka Teishin Hospital. In addition, factors influencing PS change and interruption of treatment were assessed in patients undergoing radical and palliative radiotherapy. Among elderly patients aged 80 years or more (n=67), two patients showed deterioration in PS (3%), whereas 128 (10%) did so among those 79 years old or younger. The rate of treatment completion was 90% (60/67) for patients aged 80 years and over compared with 89% (1146/1286) for younger patients. Changes in PS were more frequent for palliative treatment (improvement 83/683, 12%; deterioration 77/683, 11%) than for radical treatment (improvement 12/305, 4%:, deterioration 21/305, 7%) because patients with better performance status and early disease stages underwent radical treatment. For radical radiotherapy, patients with advanced disease (stages III and IV) showed more changes (improvement 4/108, 4%; deterioration 17/108, 16%) than those with early ones (stages I and II) (improvement 7/132, 5%; deterioration 3/132, 2%) (p<0.01). Better treatment results showed a higher treatment completion rate (CR 99%, PR 86%) than poor treatment results (NC 75%, PD 50%) (p<0.01). For palliative therapy, better performance status (PS 0-2) showed a better correlation with completion of treatment (403/451 or 89%) than did poor performance status (PS 3-4) (174/232, 75%) (p<0.01). Age is not a limiting factor for external radiation therapy. Poor performance status is a significant predisposing factor for interruption of palliative radiotherapy. (author)

  13. Status of superconducting RF test facility (STF)

    International Nuclear Information System (INIS)

    Hayano, Hitoshi

    2005-01-01

    A superconducting technology was recommended for the main linac design of the International Linear Collider (ILC) by the International Technology Recommendation Panel (ITRP). The basis for this design has been developed and tested at DESY, and R and D is progressing at many laboratories around the world including DESY, Orsay, KEK, FNAL, SLAC, Cornell, and JLAB. In order to promote Asian SC-technology for ILC, construction of a test facility in KEK was discussed and decided. The role and status of the superconducting RF test facility (STF) is reported in this paper. (author)

  14. Growth performance, immune status and organ morphometry in ...

    African Journals Online (AJOL)

    Growth performance, immune status and organ morphometry in broilers fed Bacillus subtilis -supplemented diet. ... In conclusion, B. subtilis-type probiotics contributed positively to better growth performance, improved immune system and modulated morphology of lymphoid organs and gut mucosa in broilers. Keywords: ...

  15. Stereotactic Radiosurgery for Poor Performance Status Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kubicek, Gregory J., E-mail: kubicek-gregory@cooperhealth.edu [Department of Radiation Oncology, Cooper University Hospital, Camden, New Jersey (United States); Turtz, Alan [Department of Neurological Surgery, Cooper University Hospital, Camden, New Jersey (United States); Xue, Jinyu; Patel, Ashish; Richards, Gregory; LaCouture, Tamara [Department of Radiation Oncology, Cooper University Hospital, Camden, New Jersey (United States); Cappelli, Louis; Diestelkamp, Tim [Rowan Graduate School, Camden, New Jersey (United States); Saraiya, Piya [Department of Diagnostic Radiology, Cooper University Hospital, Camden, New Jersey (United States); Bexon, Anne [Department of Neurological Surgery, Cooper University Hospital, Camden, New Jersey (United States); Lerman, Nati [Department of Medical Oncology, Cooper University Hospital, Camden, New Jersey (United States); Goldman, Howard Warren [Department of Neurological Surgery, Cooper University Hospital, Camden, New Jersey (United States)

    2016-07-01

    Purpose: Patients with poor performance status (PS), usually defined as a Karnofsky Performance Status of 60 or less, were not eligible for randomized stereotactic radiosurgery (SRS) studies, and many guidelines suggest that whole-brain radiation therapy (WBRT) is the most appropriate treatment for poor PS patients. Methods and Materials: In this retrospective review of our SRS database, we identified 36 patients with PS of 60 or less treated with SRS for central nervous system (CNS) metastatic disease. PS, as defined by the Karnofsky Performance Status, was 60 (27 patients), 50 (8 patients), or 40 (1 patient). The median number of CNS lesions treated was 3. Results: Median overall survival (OS) was 7.2 months (range, 0.73-25.6 months). Fifteen patients (41%) were alive at 6 months, and 6 patients (16.6%) were alive at 1 year. There was no difference in OS in patients who underwent previous WBRT. There were no local failures or cases of radiation toxicity. Distant CNS failures were seen in 9 patients (25%). Conclusions: Our patients with poor PS had reasonable median OS and relatively low distant CNS failure rates. Patients in this patient population may be ideal candidates for SRS compared with WBRT given the low incidence of distant failure over their remaining lives and the favorable logistics of single-fraction treatment for these patients with debility and their caregivers.

  16. A national cohort study of parental socioeconomic status and non-fatal suicidal behaviour-the mediating role of school performance

    Directory of Open Access Journals (Sweden)

    Jablonska Beata

    2012-01-01

    Full Text Available Abstract Background A link between low parental socioeconomic status and mental health problems in offspring is well established in previous research. The mechanisms that explain this link are largely unknown. The present study investigated whether school performance was a mediating and/or moderating factor in the path between parental socioeconomic status and the risk of hospital admission for non-fatal suicidal behaviour. Methods A national cohort of 447 929 children born during 1973-1977 was followed prospectively in the National Patient Discharge Register from the end of their ninth and final year of compulsory school until 2001. Multivariate Cox proportional hazards and linear regression analyses were performed to test whether the association between parental socioeconomic status and non-fatal suicidal behaviour was mediated or moderated by school performance. Results The results of a series of multiple regression analyses, adjusted for demographic variables, revealed that school performance was as an important mediator in the relationship between parental socioeconomic status and risk of non-fatal suicidal behaviour, accounting for 60% of the variance. The hypothesized moderation of parental socioeconomic status-non-fatal suicidal behaviour relationship by school performance was not supported. Conclusions School performance is an important mediator through which parental socioeconomic status translates into a risk for non-fatal suicidal behaviour. Prevention efforts aimed to reduce socioeconomic inequalities in non-fatal suicidal behaviour among young people will need to consider socioeconomic inequalities in school performance.

  17. Effect of 12-Week Vitamin D Supplementation on 25[OH]D Status and Performance in Athletes with a Spinal Cord Injury

    Directory of Open Access Journals (Sweden)

    Joelle Leonie Flueck

    2016-09-01

    Full Text Available (1 Background: studies with able-bodied athletes showed that performance might possibly be influenced by vitamin D status. Vitamin D seems to have a direct impact on neuromuscular function by docking on vitamin D receptors in the muscle tissue. Additionally, a high prevalence of vitamin D deficiency was shown not only in infants and in the elderly but also in healthy adults and spinal cord injured individuals. Therefore, the aim of our study was to investigate whether a vitamin D dose of 6000 IU daily over 12 weeks would be sufficient to increase vitamin D status in indoor wheelchair athletes to a normal or optimal vitamin D level and whether vitamin D deficiency is associated with an impairment in muscle performance in these individuals; (2 Methods: vitamin D status was assessed in indoor elite wheelchair athletes in order to have a baseline measurement. If vitamin D status was below 75 nmol/L, athletes were supplemented with 6000 IU of vitamin D daily over 12 weeks. A vitamin D status over 75 nmol/L was supplemented with a placebo supplement. Vitamin D status, as well as a Wingate test and an isokinetic dynamometer test, were performed at baseline and after six and 12 weeks; (3 Results: 20 indoor elite wheelchair athletes participated in this double-blind study. All of these athletes showed an insufficient vitamin D status at baseline and were, therefore, supplemented with vitamin D. All athletes increased vitamin D status significantly over 12 weeks and reached an optimal level. Wingate performance was not significantly increased. Isokinetic dynamometer strength was significantly increased but only in the non-dominant arm in isometric and concentric elbow flexion; (4 Conclusion: a dose of 6000 IU of vitamin D daily over a duration of 12 weeks seems to be sufficient to increase vitamin D status to an optimal level in indoor wheelchair athletes. It remains unclear, whether upper body performance or muscle strength and vitamin D status are

  18. Effects of prior testing lasting a full year in NCANDA adolescents: Contributions from age, sex, socioeconomic status, ethnicity, site, family history of alcohol or drug abuse, and baseline performance

    Directory of Open Access Journals (Sweden)

    Edith V. Sullivan

    2017-04-01

    Full Text Available Longitudinal study provides a robust method for tracking developmental trajectories. Yet inherent problems of retesting pose challenges in distinguishing biological developmental change from prior testing experience. We examined factors potentially influencing change scores on 16 neuropsychological test composites over 1 year in 568 adolescents in the National Consortium on Alcohol and NeuroDevelopment in Adolescence (NCANDA project. The twice-minus-once-tested method revealed that performance gain was mainly attributable to testing experience (practice with little contribution from predicted developmental effects. Group mean practice slopes for 13 composites indicated that 60% to ∼100% variance was attributable to test experience; General Ability accuracy showed the least practice effect (29%. Lower baseline performance, especially in younger participants, was a strong predictor of greater gain. Contributions from age, sex, ethnicity, examination site, socioeconomic status, or family history of alcohol/substance abuse were nil to small, even where statistically significant. Recognizing that a substantial proportion of change in longitudinal testing, even over 1-year, is attributable to testing experience indicates caution against assuming that performance gain observed during periods of maturation necessarily reflects development. Estimates of testing experience, a form of learning, may be a relevant metric for detecting interim influences, such as alcohol use or traumatic episodes, on behavior.

  19. TESLA Test Facility. Status

    International Nuclear Information System (INIS)

    Aune, B.

    1996-01-01

    The TESLA Test Facility (TTF), under construction at DESY by an international collaboration, is an R and D test bed for the superconducting option for future linear e+/e-colliders. It consists of an infrastructure to process and test the cavities and of a 500 MeV linac. The infrastructure has been installed and is fully operational. It includes a complex of clean rooms, an ultra-clean water plant, a chemical etching installation and an ultra-high vacuum furnace. The linac will consist of four cryo-modules, each containing eight 1 meter long nine-cell cavities operated at 1.3 GHz. The base accelerating field is 15 MV/m. A first injector will deliver a low charge per bunch beam, with the full average current (8 mA in pulses of 800 μs). A more powerful injector based on RF gun technology will ultimately deliver a beam with high charge and low emittance to allow measurements necessary to qualify the TESLA option and to demonstrate the possibility of operating a free electron laser based on the Self-Amplified-Spontaneous-Emission principle. Overview and status of the facility will be given. Plans for the future use of the linac are presented. (R.P.)

  20. Predicting neuropsychological test performance on the basis of temporal orientation.

    Science.gov (United States)

    Ryan, Joseph J; Glass, Laura A; Bartels, Jared M; Bergner, CariAnn M; Paolo, Anthony M

    2009-05-01

    Temporal orientation is often disrupted in the context of psychiatric or neurological disease; tests assessing this function are included in most mental status examinations. The present study examined the relationship between scores on the Temporal Orientation Scale (TOS) and performance on a battery of tests that assess memory, language, and cognitive functioning in a sample of patients with Alzheimer's disease (N = 55). Pearson-product moment correlations showed that, in all but two instances, the TOS was significantly correlated with each neuropsychological measure, p values < or = .05. Also, severely disoriented (i.e., TOS score < or = -8) patients were consistently 'impaired' on memory tests but not on tests of language and general cognitive functioning.

  1. Development of turbopump cavitation performance test facility and the test of inducer performance

    International Nuclear Information System (INIS)

    Sohn, Dong Kee; Kim, Chun Tak; Yoon, Min Soo; Cha, Bong Jun; Kim, Jin Han; Yang, Soo Seok

    2001-01-01

    A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar, rotational speed - 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification

  2. Seismic proving test of ultimate piping strength (current status of preliminary tests)

    International Nuclear Information System (INIS)

    Suzuki, K.; Namita, Y.; Abe, H.; Ichihashi, I.; Suzuki, K.; Ishiwata, M.; Fujiwaka, T.; Yokota, H.

    2001-01-01

    In 1998 Fiscal Year, the 6 year program of piping tests was initiated with the following objectives: i) to clarify the elasto-plastic response and ultimate strength of nuclear piping, ii) to ascertain the seismic safety margin of the current seismic design code for piping, and iii) to assess new allowable stress rules. In order to resolve extensive technical issues before proceeding on to the seismic proving test of a large-scale piping system, a series of preliminary tests of materials, piping components and simplified piping systems is intended. In this paper, the current status of the material tests and the piping component tests is reported. (author)

  3. Waste package materials testing for a salt repository: 1983 status summary report

    International Nuclear Information System (INIS)

    Moak, D.P.

    1986-09-01

    The United States plans to safely dispose of nuclear waste in deep, stable geologic formations. As part of these plans, the US Department of Energy is sponsoring research on the designing and testing of waste packages and waste package materials. This fiscal year 1983 status report summarizes recent results of waste package materials testing in a salt environment. The results from these tests will be used by waste package designers and performance assessment experts. Release characteristics data are available on two waste forms (spent fuel and waste-containing glass) that were exposed to leaching tests at various radiation levels, temperatures, pH, glass surface area to solution volume ratios, and brine solutions simulating expected salt repository conditions. Candidate materials tested for corrosion resistance and other properties include iron alloys; TI-CODE 12, the most promising titanium alloy for containment; and nickel alloys. In component interaction testing, synergistic effects have not ruled out any candidate material. 21 refs., 37 figs., 15 tabs

  4. Physical performance in relation to menopause status and physical activity.

    Science.gov (United States)

    Bondarev, Dmitriy; Laakkonen, Eija K; Finni, Taija; Kokko, Katja; Kujala, Urho M; Aukee, Pauliina; Kovanen, Vuokko; Sipilä, Sarianna

    2018-05-21

    The aim of this study was to examine differences in physical performance (muscle power, muscle strength, aerobic capacity, and walking speed) across menopausal stages and potential of leisure physical activity (PA) to modify the impact of menopause on physical performance. In this cross-sectional study, women aged 47 to 55 were randomly selected from the Finnish National Registry and categorized as premenopausal (n = 233), perimenopausal (n = 381), or postmenopausal (n = 299) based on serum concentrations of follicle-stimulating hormone and bleeding diary. Physical performance was measured by knee extension force, handgrip force, vertical jumping height, maximal walking speed, and 6-minute walking distance. PA level was assessed by self-report and categorized as low, moderate, or high. Multivariate linear regression modeling was used for data analysis. After including fat mass, height, PA, and education in the model, the postmenopausal women showed 12.0 N weaker (P women. There was no significant interaction between menopausal stage and PA on physical performance. The peri- and postmenopausal women with a high PA, however, showed better performance in the maximal knee extension strength and 6-minute walking test, and showed greater lower body muscle power than those with a low PA. Menopause status is associated with muscle strength and power, whereas the association between menopause status and mobility/walking is clearly weaker. A high leisure PA level provides more capacity to counteract the potential negative influence of menopausal factors on muscle function.This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0.

  5. Effect of iodine status and other nutritional factors on psychomotor and cognitive performance of Filipino schoolchildren.

    Science.gov (United States)

    Amarra, Ma Sofia V; Bongga, Demetria C; Peñano-Ho, Leticia; Cruz, Federico B; Solis, José S; Barrios, Erniel B

    2007-03-01

    Until 1998, iodine deficiency was a public health problem in the Philippines. A law entitled "An Act Promoting Salt Iodization Nationwide" (ASIN) has been passed and implemented by the government to eliminate iodine deficiency. The contribution of salt iodization, as well as dietary, health, and environmental factors, to improving the intellectual performance of Filipino schoolchildren remains to be determined. The objectives of the study were to determine the relationship between iodine status and levels of psychomotor and cognitive performance in first-grade children aged 6 to 10 years, and to examine the extent to which dietary, biochemical, health, and environmental factors contribute to children's mental performance. Two hundred ninety children in six classroom sections from a public school in Manila were examined by measurement of urinary iodine excretion (UIE) and thyroid palpation. The median UIE level for each section was determined. Sixty-five children classified as iodine deficient (UIE 100 microg/L without goiter, n = 31) were given psychomotor and cognitive function tests (Bender-Gestalt and Raven's Colored Progressive Matrices). Scores from the two tests were used to determine each child's general ability percentile rank. Other variables examined were dietary intake (% RDA of nutrients ingested based on two nonconsecutive 24-hour recalls); deficiencies in iron, vitamin A, and selenium; parasitic infection; coliform contamination of drinking water; household use of iodized salt; illness in the past 2 weeks; and wasting and stunting. Children whose general ability scores were at or above the 50th percentile had higher UIE levels, but the relationship was not significant. Children from sections with higher median UIE levels had higher percentile ranks for general ability (p = .002). Backward logistic regression showed that the variance in deficient and adequate mental performance was explained by dietary intakes that met > or = 80% of the RDA for energy

  6. Influence of socioeconomic and demographic status on spirometry testing in patients initiating medication targeting obstructive lung disease

    DEFF Research Database (Denmark)

    Koefoed, Mette M; Søndergaard, Jens; Christensen, René Depont

    2013-01-01

    a possible association between education, income, labour market affiliation, cohabitation status and having spirometry performed when initiating medication targeting obstructive pulmonary disease. METHODS: We conducted a population-based cohort study. Danish national registers were linked, retrieving data...... on prescriptions, spirometry testing, socioeconomic and demographic variables in all first time users of medication targeting obstructive lung disease in 2008. RESULTS: A total of 37,734 persons were included and approximately half of the cohort had spirometry performed. Among medication users under 65 years...... spirometry performed among men (OR = 0.78, CI = 0.69-0.88). CONCLUSION: Social inequity in spirometry testing among patients initiating medication targeting obstructive lung disease was confirmed in this study. Increased focus on spirometry testing among elderly men living alone, among the unemployed...

  7. ATLAS RPC commissioning status and cosmic ray test results

    CERN Document Server

    Bianco, Michele

    2009-01-01

    The muon trigger system of the ATLAS experiment consists of several sub-systems and each of them need to be tested and certified before LHC operation. In the barrel region Resistive Plate Chambers are employed. RPC detector and its level-1 trigger electronics are designed to detect and select high momentum muons with high time resolution and good tracking capability for a total surface of about 4000 m2. The commissioning phase provided an unique opportunity to demonstrate, before LHC start-up, the functionality of the muon trigger components such as detector chambers, level-1 trigger electronics, detector slow control system, data acquisition chain, software and computing. We present the status of ATLAS RPC detector, the problems met during the commissioning and the solutions found and, finally, its performances as obtained by acquiring cosmic rays.

  8. Developing standard performance testing procedures for MC and A components at a site

    International Nuclear Information System (INIS)

    Scherer, Carolynn

    2010-01-01

    The condition of a nuclear material control and accountability system (MC and A) and its individual components, as with any system combining technical elements, documentation and the human factor, may be characterized through an aggregate of values for the various parameters that determine the system's ability to perform. The MC and A system's status may be functioning effectively, marginally or not functioning based on a summary of the values of the individual parameters. This work included a review of the following elements and subsystems or components for a material control and accountability system: (1) MC and A Elements: Information subsystem, Measurement subsystem, NM access subsystem, including a tamper-indicating device (TID) program, and Automated information-gathering subsystem; and (2) Detecting NM Loses Elements: Inventory differences, Shipper/receiver differences, Confirmatory measurements and differences with accounting data, and TID or seal violations. In order to detect the absence or loss of nuclear material there must be appropriate interactions among the elements and their respective subsystems (from the list above). Additionally this work includes a review of the status of regulatory requirements for the MC and A system components and potential criteria that support the evaluation of the performance of the listed components. The listed components had performance testing algorithms and procedures developed that took into consideration the regulatory criteria. The developed MC and A performance-testing procedures were the basis for a pilot Guide for MC and A Performance Testing at the MBAs of SSC RF IPPE.

  9. Assessment of Mental Status.

    Science.gov (United States)

    Finney, Glen R; Minagar, Alireza; Heilman, Kenneth M

    2016-02-01

    Assessing the mental status of patients with a neurobehavioral disorder is a critical element in the diagnosis and treatment of these patients. This assessment should always be performed after the patient's history it taken and a general physical as well as a neurologic examination is completed. The mental status examination commences with observing the patient's appearance and level of consciousness. The examiner should also pay attention to patient's social behavior, emotional state and mood. There are 3 major means of assessing a patient's mental status. One type attempts to determine if the patient is demented and the severity of the dementia as it pertains to their ability to perform activities of daily living as well as instrumental activities. A second type of assessment utilizes what may be termed as "screening tests" or "omnibus tests". These brief tests are performed independent of the patient's history and examination. The two most frequently used screening tests are the Mini-Mental Status Examination (MMSE) and the Montreal Cognitive Assessment (MoCA). The third means of assessing a patient's mental status is by using specific neuropsychological tests that focus on specific domains of cognition, such as frontal executive functions, attention, episodic verbal and visuospatial memory, declarative knowledge such as language (speech, reading and writing) and arithmetical, as well as visuospatial and perceptual abilities. These neurobehavioral, neuropsychiatric and neuropsychological assessments of patients with a cognitive decline and behavioral abnormalities should often be accompanied by laboratory tests, and neuroimaging that can help determine the underlying pathologic process so that effective therapeutic and management approaches can be provided. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Performance testing of UK personal dosimetry laboratories

    CERN Document Server

    Marshall, T O

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it...

  11. Status and future plans of the Drones for Aerodynamic and Structural Testing (DAST) program. [Aeroelastic Research Wing (ARW)

    Science.gov (United States)

    Murrow, H. N.

    1981-01-01

    Results from flight tests of the ARW-1 research wing are presented. Preliminary loads data and experiences with the active control system for flutter suppression are included along with comparative results of test and prediction for the flutter boundary of the supercritical research wing and on performance of the flutter suppression system. The status of the ARW-2 research wing is given.

  12. Removal of Endobronchial Malignant Mass by Cryotherapy Improved Performance Status to Receive Chemotherapy

    Science.gov (United States)

    Hsieh, Meng-Heng; Wang, Tsai-Yu; Yu, Chih-Teng; Chou, Chun-Liang; Lin, Shu-Min; Kuo, Chih-Hsi; Chung, Fu-Tsai

    2014-01-01

    Although malignant endobronchial mass (MEM) has poor prognosis, cryotherapy is reportedly a palliative treatment. Clinical data on postcryotherapy MEM patients in a university-affiliated hospital between 2007 and 2011 were evaluated. Survival curve with or without postcryotherapy chemotherapy and performance status (PS) improvement of these subjects were analyzed using the Kaplan-Meier method. There were 59 patients (42 males), with median age of 64 years (range, 51–76, and median performance status of 2 (interquartile range [IQR], 2-3). Postcryotherapy complications included minor bleeding (n = 12) and need for multiple procedures (n = 10), while outcomes were relief of symptoms (n = 51), improved PS (n = 45), and ability to receive chemotherapy (n = 40). The survival of patients with chemotherapy postcryotherapy was longer than that of patients without such chemotherapy (median, 534 versus 106 days; log-rank test, P = 0.007; hazard ratio, 0.25; 95% confidence interval, 0.10–0.69). The survival of patients with PS improvement postcryotherapy was longer than that of patients without PS improvement (median, 406 versus 106 days; log-rank test, P = 0.02; hazard ratio, 0.28; 95% confidence interval, 0.10–0.81). Cryotherapy is a feasible treatment for MEM. With better PS after cryotherapy, further chemotherapy becomes possible for patients to improve survival when MEM caused dyspnea and poor PS. PMID:25383370

  13. Textiles Performance Testing Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Textiles Performance Testing Facilities has the capabilities to perform all physical wet and dry performance testing, and visual and instrumental color analysis...

  14. Status and performance of PF injector linac

    International Nuclear Information System (INIS)

    Sato, Isamu

    1994-01-01

    PF injector linac has been improved on a buncher section for accelerating of intense electron beam, and reinforced a focusing system of the positron generator linac for the expansion of phase space. In this presentation, I shall report present status and performance of PF injector linac, and discuss its upgrade program for B-factory project. (author)

  15. Operator performance in non-destructive testing: A study of operator performance in a performance test

    Energy Technology Data Exchange (ETDEWEB)

    Enkvist, J.; Edland, A.; Svenson, Ola [Stockholm Univ. (Sweden). Dept. of Psychology

    2000-05-15

    In the process industries there is a need of inspecting the integrity of critical components without disrupting the process. Such in-service inspections are typically performed with non-destructive testing (NDT). In NDT the task of the operator is to (based on diagnostic information) decide if the component can remain in service or not. The present study looks at the performance in NDT. The aim is to improve performance, in the long run, by exploring the operators' decision strategies and other underlying factors and to this way find out what makes some operators more successful than others. Sixteen operators performed manual ultrasonic inspections of four test pieces with the aim to detect (implanted) cracks. In addition to these performance demonstration tests (PDT), the operators performed independent ability tests and filled out questionnaires. The results show that operators who trust their gut feeling more than the procedure (when the two come to different results) and that at the same time have a positive attitude towards the procedure have a higher PDT performance. These results indicate the need for operators to be motivated and confident when performing NDT. It was also found that the operators who performed better rated more decision criteria higher in the detection phase than the operators who performed worse. For characterizing it was the other way around. Also, the operators who performed better used more time, both detecting and characterizing, than the operators who performed worse.

  16. Operator performance in non-destructive testing: A study of operator performance in a performance test

    International Nuclear Information System (INIS)

    Enkvist, J.; Edland, A.; Svenson, Ola

    2000-05-01

    In the process industries there is a need of inspecting the integrity of critical components without disrupting the process. Such in-service inspections are typically performed with non-destructive testing (NDT). In NDT the task of the operator is to (based on diagnostic information) decide if the component can remain in service or not. The present study looks at the performance in NDT. The aim is to improve performance, in the long run, by exploring the operators' decision strategies and other underlying factors and to this way find out what makes some operators more successful than others. Sixteen operators performed manual ultrasonic inspections of four test pieces with the aim to detect (implanted) cracks. In addition to these performance demonstration tests (PDT), the operators performed independent ability tests and filled out questionnaires. The results show that operators who trust their gut feeling more than the procedure (when the two come to different results) and that at the same time have a positive attitude towards the procedure have a higher PDT performance. These results indicate the need for operators to be motivated and confident when performing NDT. It was also found that the operators who performed better rated more decision criteria higher in the detection phase than the operators who performed worse. For characterizing it was the other way around. Also, the operators who performed better used more time, both detecting and characterizing, than the operators who performed worse

  17. Performed and perceived walking ability in relation to the Expanded Disability Status Scale in persons with multiple sclerosis

    DEFF Research Database (Denmark)

    Langeskov-Christensen, D; Feys, P; Baert, I

    2017-01-01

    BACKGROUND: The severity of walking impairment in persons with multiple sclerosis (pwMS) at different levels on the expanded disability status scale (EDSS) is unclear. Furthermore, it is unclear if the EDSS is differently related to performed- and perceived walking capacity tests. AIMS: To quantify...

  18. Performance testing of UK personal dosimetry laboratories

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it are also estimated. (author)

  19. Can trained lay providers perform HIV testing services? A review of national HIV testing policies.

    Science.gov (United States)

    Flynn, David E; Johnson, Cheryl; Sands, Anita; Wong, Vincent; Figueroa, Carmen; Baggaley, Rachel

    2017-01-04

    Only an estimated 54% of people living with HIV are aware of their status. Despite progress scaling up HIV testing services (HTS), a testing gap remains. Delivery of HTS by lay providers may help close this testing gap, while also increasing uptake and acceptability of HIV testing among key populations and other priority groups. 50 National HIV testing policies were collated from WHO country intelligence databases, contacts and testing program websites. Data regarding lay provider use for HTS was extracted and collated. Our search had no geographical or language restrictions. This data was then compared with reported data from the Global AIDS Response Progress Reporting (GARPR) from July 2015. Forty-two percent of countries permit lay providers to perform HIV testing and 56% permit lay providers to administer pre-and post-test counseling. Comparative analysis with GARPR found that less than half (46%) of reported data from countries were consistent with their corresponding national HIV testing policy. Given the low uptake of lay provider use globally and their proven use in increasing HIV testing, countries should consider revising policies to support lay provider testing using rapid diagnostic tests.

  20. The status of ANSI N13.11 - The dosimeter performance test standard

    International Nuclear Information System (INIS)

    Sims, C.S.

    1991-01-01

    The standard designated ANSI N13.11 was issued in 1983 and is the basis for the dosimeter performance test associated with the National Voluntary Laboratory Accreditation Program (NVLAP). The standard is important because the Nuclear Regulatory Commission requires that all licensees use personnel dosimeters processed by NVLAP-accredited processors. The standard has undergone review and modifications have been recommended. Historical information concerning the development and utilization of the present standard, ANSI N13.11-1983, is presented. Details associated with the review of the standard (e.g., policy, group selection) are then given. Finally, the modifications recommended by the review group are discussed

  1. Children with minimal sensorineural hearing loss: prevalence, educational performance, and functional status.

    Science.gov (United States)

    Bess, F H; Dodd-Murphy, J; Parker, R A

    1998-10-01

    This study was designed to determine the prevalence of minimal sensorineural hearing loss (MSHL) in school-age children and to assess the relationship of MSHL to educational performance and functional status. To determine prevalence, a single-staged sampling frame of all schools in the district was created for 3rd, 6th, and 9th grades. Schools were selected with probability proportional to size in each grade group. The final study sample was 1218 children. To assess the association of MSHL with educational performance, children identified with MSHL were assigned as cases into a subsequent case-control study. Scores of the Comprehensive Test of Basic Skills (4th Edition) (CTBS/4) then were compared between children with MSHL and children with normal hearing. School teachers completed the Screening Instrument for Targeting Education Risk (SIFTER) and the Revised Behavior Problem Checklist for a subsample of children with MSHL and their normally hearing counterparts. Finally, data on grade retention for a sample of children with MSHL were obtained from school records and compared with school district norm data. To assess the relationship between MSHL and functional status, test scores of all children with MSHL and all children with normal hearing in grades 6 and 9 were compared on the COOP Adolescent Chart Method (COOP), a screening tool for functional status. MSHL was exhibited by 5.4% of the study sample. The prevalence of all types of hearing impairment was 11.3%. Third grade children with MSHL exhibited significantly lower scores than normally hearing controls on a series of subtests of the CTBS/4; however, no differences were noted at the 6th and 9th grade levels. The SIFTER results revealed that children with MSHL scored poorer on the communication subtest than normal-hearing controls. Thirty-seven percent of the children with MSHL failed at least one grade. Finally, children with MSHL exhibited significantly greater dysfunction than children with normal hearing

  2. Nutritional Status and Cognitive Performance among Children Aged ...

    African Journals Online (AJOL)

    Without adequate nutrition, children cannot develop to their full physical and mental potentials. The nutritional status and the cognitive performance of 500 school children aged 5-12 years from urban and rural areas of Enugu State, Nigeria were evaluated. Anthropometric measurements of heights and weights were ...

  3. Overview and status of the SIMMER testing program

    International Nuclear Information System (INIS)

    Scott, J.H.

    1979-01-01

    Los Alamos Scientific Laboratory has undertaken an extensive experiment analysis program to test the results of SIMMER Liquid Metal Fast Breeder Reactor (LMFBR) accident calculations. Initially, we will test the postdisassembly work-energy partition problem. The SIMMER-calculated order-of-magnitude reduction of available kinetic energy following a severe hypothetical core-disruptive accident (HCDA) can be attributed to (1) purely fluid-dynamic effects; and (2) rate-controlled effects, such as phase transitions and heat transfer. We have chosen to test separately each class of mitigator. In this paper we review the experiments initially chosen for testing of each class of mitigator and report on the status of the analyses. We enumerate several problems in SIMMER that experiment analysis has disclosed. Finally, needs for future experiments are discussed

  4. The association of iron status with educational performance and intelligence among adolescents.

    Science.gov (United States)

    Dissanayake, D S; Kumarasiri, P V R; Nugegoda, D B; Dissanayake, D M

    2009-09-01

    The aim was to identify the association of iron status with educational performance and intelligence of adolescents. This was a cross sectional comparative study among adolescents aged 13-15 years. Each iron deficient student was matched with an iron sufficient student from the same school, class and sex. Iron status was based on haemoglobin and serum ferritin levels. The marks for mathematics, science, Sinhala language and social science were considered to assess educational performance. Intelligence was measured by Raven's Standard progressive matrices. All the possible confounders and effect modifiers were considered. Home visits to a sub-sample checked the quality of data. The final analysis included 188 students (94 matched pairs). Neither educational performance nor intelligence showed significant associations with the iron status. The severity of the iron deficiency did not relate to these cognitive variables either. Twenty-three and 8 co-variables showed statistically significant associations with educational performance and intelligence respectively. Following a multiple regression analysis intelligence, the enthusiasm of the student towards learning, occupational ambition, household possession, problems at home and private tuition for mathematics were key factors predicting educational performance. Stunting and educational level of the mother were important factors influencing intelligence. Iron status does not play a major role in educational performance and intelligence of school going adolescents. Several factors affect educational performance and intelligence. This study highlights the difficulty in extrapolating the findings of similar studies to different ecological settings.

  5. Is High-Stakes Testing Harming Lower Socioeconomic Status Schools?

    Science.gov (United States)

    Cunningham, William G.; Sanzo, Tiffany D.

    2002-01-01

    A strong relationship is shown between students' state assessment test pass rates and students' socioeconomic status (SES). State sanctions based on assessment scores can affect graduation, student diplomas, school accreditation, school funding, teacher rewards and promotion, paperwork requirements, regulations, work expectations, improvement…

  6. Star Excursion Balance Test Anterior Asymmetry Is Associated With Injury Status in Division I Collegiate Athletes.

    Science.gov (United States)

    Stiffler, Mikel R; Bell, David R; Sanfilippo, Jennifer L; Hetzel, Scott J; Pickett, Kristen A; Heiderscheit, Bryan C

    2017-05-01

    Study Design Retrospective cohort. Background Star Excursion Balance Test (SEBT) performance differs by sport in healthy collegiate athletes, and lower extremity injury rates also vary by sport, sex, and athletic exposure. The relationship between SEBT performance and injury risk has not been evaluated with consideration of these additional variables, which may be necessary to fully describe the relationship between SEBT performance and injury risk. Objectives To assess the association between preseason SEBT performance and noncontact injury occurrence to the knee or ankle in Division I collegiate athletes when controlling for sport, sex, and athletic exposure. Methods Star Excursion Balance Test performance, starting status, and injury status were reviewed retrospectively in National Collegiate Athletic Association Division I collegiate athletes from a single institution. A total of 147 athletes were healthy at the time of preseason SEBT testing and either remained healthy (n = 118) or sustained a noncontact injury to the knee or ankle (n = 29) during their sport's subsequent competitive season. Side-to-side asymmetries were calculated in each direction as the absolute difference in reach distance between limbs. Star Excursion Balance Test reach distances and asymmetries were compared between groups using multivariable regression, controlling for sport, sex, and athletic exposure (starter, nonstarter). Receiver operating characteristic curves were used to determine optimal sensitivity and specificity for significant models. Results When controlling for sport, sex, and athletic exposure, SEBT side-to-side asymmetry in the anterior direction, expressed as an absolute or normalized to limb length, discriminated between injured and noninjured athletes (area under the curve greater than 0.82). Conclusion Assessing side-to-side reach asymmetry in the anterior direction of the SEBT may assist in identifying collegiate athletes who are at risk for sustaining noncontact

  7. Present status of irradiation tests on tritium breeding blanket for fusion reactor

    International Nuclear Information System (INIS)

    Futamura, Yoshiaki; Sagawa, Hisashi; Shimakawa, Satoshi; Tsuchiya, Kunihiko; Kuroda, Toshimasa; Kawamura, Hiroshi.

    1994-01-01

    To develop a tritium breeding blanket for a fusion reactor, irradiation tests in fission reactors are indispensable for obtaining data on irradiation effects on materials, and neutronics/thermal characteristics and tritium production/recovery performance of the blanket. Various irradiation tests have been conducted in the world, especially to investigate tritium release characteristics from tritium breeding and neutron multiplier materials, and materials integrity under irradiation. In Japan, VOM experiments at JRR-2 for ceramic breeders and experiments at JMTR for ceramic breeders and beryllium as a neutron multiplier have been performed. Several universities have also investigated ceramic breeders. In the EC, the EXOTIC experiments at HFR in the Netherlands and the SIBELIUS, the LILA, the LISA and the MOZART experiments for ceramic breeders have carried out. In Canada, NRU has been used for the CRITIC experiments. The TRIO experiments at ORR(ORNL), experiments at RTNS-II, FUBR and ATR have been conducted in the USA. The last two are experiments with high neutron fluence aiming at investigating materials integrity under irradiation. The BEATRIX-I and -II experiments have proceeded under international collaboration of Japan, Canada, the EC and the USA. This report shows the present status of these irradiation tests following a review of the blanket design in the ITER CDA(Conceptual Design Activity). (author)

  8. The evaluation of the status of nondestructive testing (NDT) companies in the Philippines

    International Nuclear Information System (INIS)

    Mateo, Alejandro J.

    2002-10-01

    This research study assessed the present status of the NDT companies practicing the five techniques and methods in nondestructive testing and found answers to the following questions: what is the profile of the NDT companies and NDT personnel in terms of type, category of the company, number of years in operation, capitalization, nature of NDT services offered, number of certified NDT personnel their age, sex, marital status, educational attainment, monthly salary, NDT training and work experience of NDT personnel; what is the level of adequacy of the NDT companies based on the following organization-related factors: financial support human resources, availability of NDT/office equipment/vehicles, available facilities and quality systems; what is the status of the NDT companies in terms of level of performance, in-house activities, level of competitiveness and conformity with PNS-146:1998; are there significant differences in the perceptions of the respondent's on the status of the NDT companies when grouped according to age, sex, salary, work experience; and what personal and organizational-related factors affect the status of the NDT companies. The research study provided for the researcher an opportunity to identify and analyse the problems and concern of the local NDT sector to be able to recommend solutions for the NDT to attain the status of a profession and/or career and with all NDT companies and NDT personnel act as professionals in the performance of NDT services and other NDT-related activities. The study will achieve the following objectives: to the accredited NDT companies, the accreditation will provide the recognition of the companies as to the quality of personnel, equipment, and services they provide to the client; to the client, the accredited NDT companies will provide the assurance of the quality of personnel, equipment and service provided; to the other NDT companies, the accreditation of the NDT company will provide the impetus that they

  9. Nutritional Status and Performance in Test of Verbal and Non-Verbal Intelligence in 6-Year- Old Children

    Science.gov (United States)

    Arija, Victoria; Esparo, Griselda; Fernandez-Ballart, Joan; Murphy, Michelle M.; Biarnes, Elisabeth; Canals, Josefa

    2006-01-01

    The relationship between nutritional status and intellectual capacity in 6-year-old children was investigated in 83 subjects of medium-high socio-economic status, without any apparent risk of malnutrition and normal or high intellectual capacity. Nutritional status was evaluated by measuring food consumption, anthropometrical measurements and…

  10. Academic performance of Korean children is associated with dietary behaviours and physical status.

    Science.gov (United States)

    Kim, Hye-Young P; Frongillo, Edward A; Han, Sung-Sook; Oh, Se-Young; Kim, Woo-Kyung; Jang, Young-Ai; Won, Hye-Sook; Lee, Hyun-Sook; Kim, Sook-He

    2003-01-01

    The purpose of this study was to obtain a fuller understanding of the association of dietary behaviours, physical status and socio-economic status with academic performance in Korean teenagers. The subjects in this study were 6,463 boys and girls, in grade 5, 8, and 11 in Korea. A self-administered questionnaire and the food-frequency form were used. Grade point average (GPA), height, weight, and physical fitness score for the year were recorded from the school record. The academic performance of students was strongly associated with dietary behaviours, especially with regularity of three meals even after control for parent's education level. Regular breakfast and lunch were more important in grades 5 and 8, while regular dinner was more related with academic performance in grade 11. Small, positive associations of height and physical fitness to academic performance were also found. The relative importance of regularity of meals was greater than that of socio-economic status and physical status in older teenagers. The results of this study suggest that accommodation of better dietary environment and nutrition education for three regular meals is recommended.

  11. Insights into Sexism: Male Status and Performance Moderates Female-Directed Hostile and Amicable Behaviour.

    Directory of Open Access Journals (Sweden)

    Michael M Kasumovic

    Full Text Available Gender inequality and sexist behaviour is prevalent in almost all workplaces and rampant in online environments. Although there is much research dedicated to understanding sexist behaviour, we have almost no insight into what triggers this behaviour and the individuals that initiate it. Although social constructionist theory argues that sexism is a response towards women entering a male dominated arena, this perspective doesn't explain why only a subset of males behave in this way. We argue that a clearer understanding of sexist behaviour can be gained through an evolutionary perspective that considers evolved differences in intra-sexual competition. We hypothesised that female-initiated disruption of a male hierarchy incites hostile behaviour from poor performing males who stand to lose the most status. To test this hypothesis, we used an online first-person shooter video game that removes signals of dominance but provides information on gender, individual performance, and skill. We show that lower-skilled players were more hostile towards a female-voiced teammate, especially when performing poorly. In contrast, lower-skilled players behaved submissively towards a male-voiced player in the identical scenario. This difference in gender-directed behaviour became more extreme with poorer focal-player performance. We suggest that low-status males increase female-directed hostility to minimize the loss of status as a consequence of hierarchical reconfiguration resulting from the entrance of a woman into the competitive arena. Higher-skilled players, in contrast, were more positive towards a female relative to a male teammate. As higher-skilled players have less to fear from hierarchical reorganization, we argue that these males behave more positively in an attempt to support and garner a female player's attention. Our results provide the clearest picture of inter-sexual competition to date, highlighting the importance of considering an evolutionary

  12. Insights into Sexism: Male Status and Performance Moderates Female-Directed Hostile and Amicable Behaviour.

    Science.gov (United States)

    Kasumovic, Michael M; Kuznekoff, Jeffrey H

    2015-01-01

    Gender inequality and sexist behaviour is prevalent in almost all workplaces and rampant in online environments. Although there is much research dedicated to understanding sexist behaviour, we have almost no insight into what triggers this behaviour and the individuals that initiate it. Although social constructionist theory argues that sexism is a response towards women entering a male dominated arena, this perspective doesn't explain why only a subset of males behave in this way. We argue that a clearer understanding of sexist behaviour can be gained through an evolutionary perspective that considers evolved differences in intra-sexual competition. We hypothesised that female-initiated disruption of a male hierarchy incites hostile behaviour from poor performing males who stand to lose the most status. To test this hypothesis, we used an online first-person shooter video game that removes signals of dominance but provides information on gender, individual performance, and skill. We show that lower-skilled players were more hostile towards a female-voiced teammate, especially when performing poorly. In contrast, lower-skilled players behaved submissively towards a male-voiced player in the identical scenario. This difference in gender-directed behaviour became more extreme with poorer focal-player performance. We suggest that low-status males increase female-directed hostility to minimize the loss of status as a consequence of hierarchical reconfiguration resulting from the entrance of a woman into the competitive arena. Higher-skilled players, in contrast, were more positive towards a female relative to a male teammate. As higher-skilled players have less to fear from hierarchical reorganization, we argue that these males behave more positively in an attempt to support and garner a female player's attention. Our results provide the clearest picture of inter-sexual competition to date, highlighting the importance of considering an evolutionary perspective when

  13. Cortical Brain Atrophy and Intra-Individual Variability in Neuropsychological Test Performance in HIV Disease

    Science.gov (United States)

    HINES, Lindsay J.; MILLER, Eric N.; HINKIN, Charles H.; ALGER, Jeffery R.; BARKER, Peter; GOODKIN, Karl; MARTIN, Eileen M.; MARUCA, Victoria; RAGIN, Ann; SACKTOR, Ned; SANDERS, Joanne; SELNES, Ola; BECKER, James T.

    2015-01-01

    Objective To characterize the relationship between dispersion-based intra-individual variability (IIVd) in neuropsychological test performance and brain volume among HIV seropositive and seronegative men and to determine the effects of cardiovascular risk and HIV infection on this relationship. Methods Magnetic Resonance Imaging (MRI) was used to acquire high-resolution neuroanatomic data from 147 men age 50 and over, including 80 HIV seropositive (HIV+) and 67 seronegative controls (HIV−) in this cross-sectional cohort study. Voxel Based Morphometry was used to derive volumetric measurements at the level of the individual voxel. These brain structure maps were analyzed using Statistical Parametric Mapping (SPM2). IIVd was measured by computing intra-individual standard deviations (ISD’s) from the standardized performance scores of five neuropsychological tests: Wechsler Memory Scale-III Visual Reproduction I and II, Logical Memory I and II, Wechsler Adult Intelligence Scale-III Letter Number Sequencing. Results Total gray matter (GM) volume was inversely associated with IIVd. Among all subjects, IIVd -related GM atrophy was observed primarily in: 1) the inferior frontal gyrus bilaterally, the left inferior temporal gyrus extending to the supramarginal gyrus, spanning the lateral sulcus; 2) the right superior parietal lobule and intraparietal sulcus; and, 3) dorsal/ventral regions of the posterior section of the transverse temporal gyrus. HIV status, biological, and cardiovascular disease (CVD) variables were not linked to IIVd -related GM atrophy. Conclusions IIVd in neuropsychological test performance may be a sensitive marker of cortical integrity in older adults, regardless of HIV infection status or CVD risk factors, and degree of intra-individual variability links with volume loss in specific cortical regions; independent of mean-level performance on neuropsychological tests. PMID:26303224

  14. Human epidermal growth factor receptor 2 testing in invasive breast cancer: should histological grade, type and oestrogen receptor status influence the decision to repeat testing?

    Science.gov (United States)

    Rakha, Emad A; Pigera, Marian; Shin, Sandra J; D'Alfonso, Timothy; Ellis, Ian O; Lee, Andrew H S

    2016-07-01

    The recent American Society of Clinical Oncology/College of American Pathologists guidelines for human epidermal growth factor receptor 2 (HER2) testing in breast cancer recommend repeat testing based on tumour grade, tumour type, and hormone receptor status. The aim of this study was to test the value of these criteria. HER2 status was concordant in the core biopsies and excision specimens in 392 of 400 invasive carcinomas. The major reasons for discordance were amplification around the cut-off for positivity and tumour heterogeneity. Of 116 grade 3 carcinomas that were HER2-negative in the core biopsy, four were HER2-positive in the excision specimen. Three of these four either showed borderline negative amplification in the core biopsy or were heterogeneous. None of the 55 grade 1 carcinomas were HER2-positive. Review of repeat testing of HER2 in routine practice suggested that it may also be of value for multifocal tumours and if recommended by the person assessing the in-situ hybridization. Mandatory repeat HER2 testing of grade 3 HER2-negative carcinomas is not appropriate. This is particularly true if repeat testing is performed after borderline negative amplification in the core biopsy or in HER2-negative heterogeneous carcinomas. © 2015 John Wiley & Sons Ltd.

  15. Status of Breast Self-Examination Performance among Women Referring to Health Centers of Tabriz, Iran

    Directory of Open Access Journals (Sweden)

    Farshbaf-Khalili Azizeh

    2014-07-01

    Full Text Available Objective: Breast cancer is the most common type of cancer and the second principal cause of deaths from cancer in women. Breast self-examination (BSE is an inexpensive screening method and is carried out by women themselves. The purpose of this study was to examine the status of breast self-examination performance among women referring to health centers of Tabriz, Iran. Materials and Methods: This study was a descriptive/ cross-sectional research carried out on 400 women aged 20-50 years. The samples were recruited randomly from among female clients of health centers in Tabriz. A questionnaire and an observational checklist were used to elicit socio-demographic information and status of BSE performance among women. Content validity was used for validation and Cronbach’s alpha was calculated (0.80 for reliability of instrument. Descriptive and inferential statistics were used to analyze data through SPSS software. Results: The findings of this research showed that only 18.8% of women performed BSE. Among them, 46.67% performed BSE monthly, and 40% at the end of menstruation. The initiation age of BSE in 77% was between 21-30 years of age. It is considerable that 54.7% of them had received no advice on BSE from physicians and midwives. The majority of women did not perform the various steps of BSE. The quality of this screening was very desirable in 2 (0.5 %, desirable in 5 (1.3%, average in 19 (4.8%, undesirable in 36 (9%, and very undesirable in 338 (84.5% women. Chi-square test showed a significant relationship between the quality of BSE performance and level of education, employment, breastfeeding quality, and family history of breast cancer (P < 0.05. Conclusion: The findings showed that the status of BSE performance was very poor. Therefore, to encourage women to use BSE correctly and regularly, education programs should be performed through various media including television, radio, and leaflets. The role of Health personnel in this

  16. Influence of socioeconomic and demographic status on spirometry testing in patients initiating medication targeting obstructive lung disease: a population-based cohort study

    Science.gov (United States)

    2013-01-01

    Background Socioeconomic status is known to influence the prevalence, severity and mortality of obstructive lung diseases, but it is uncertain whether it affects the use of diagnostic spirometry in patients initiating treatment for these conditions. The objective of this paper was to examine a possible association between education, income, labour market affiliation, cohabitation status and having spirometry performed when initiating medication targeting obstructive pulmonary disease. Methods We conducted a population-based cohort study. Danish national registers were linked, retrieving data on prescriptions, spirometry testing, socioeconomic and demographic variables in all first time users of medication targeting obstructive lung disease in 2008. Results A total of 37,734 persons were included and approximately half of the cohort had spirometry performed. Among medication users under 65 years of age, being unemployed was significantly associated with reduced odds of having spirometry performed, the strongest association was seen in men (OR = 0.82, CI = 0.73-0.91). Medium income was associated with increased odds of having spirometry performed in men (OR = 1.18, CI = 1.06-1.30) and high educational level (>12 years) was associated with reduced odds of having spirometry performed in women (OR = 0.86, CI = 0.78-0.94). Cohabitation status was not associated with having spirometry performed. Among medication users over 65 years of age, living alone was associated with reduced odds of having spirometry performed among men (OR = 0.78, CI = 0.69-0.88). Conclusion Social inequity in spirometry testing among patients initiating medication targeting obstructive lung disease was confirmed in this study. Increased focus on spirometry testing among elderly men living alone, among the unemployed and among women with higher education is required when initiating medication. PMID:23768408

  17. Change in weight status and academic performance among senior high school students in Taiwan.

    Science.gov (United States)

    Liao, Pei-An; Chang, Hung-Hao; Wang, Jiun-Hao; Wu, Min-Chen

    2015-01-01

    This study examines how the changes in weight status across the spectrum of a senior high school study are associated with academic performance measured by the university entrance exam scores. A unique dataset which compiles a national health examination profile and the General Scholastic Ability Test data bank in Taiwan was constructed. The final sample comprised 149,240 senior high school students of which 70,662 were males and 78,578 were female students. The school-level fixed effect models were estimated. Students who were either (a) not overweight in the first year but overweight in the third year of senior high school, (b) overweight in both the first and third year, or (c) overweight in the first year but not overweight in the third year, were more likely to score lower on the university entrance exam, compared with their never-overweight counterparts. The findings differ by gender and test subjects. The change in weight status during senior high school period is associated with subsequent university entrance exam outcome. Students who start senior high school being overweight should be paid attention. School-based programs and practices need to be implemented to reduce the prevalence of overweight among students.

  18. Socioeconomic Status of Parents and the Achievement of Children on Readiness for School Tests

    Directory of Open Access Journals (Sweden)

    Anela Hasanagic

    2015-07-01

    Full Text Available Socioeconomic status is often determined like the academic background of parents, and it can be determined like the place of living, village or town, city, as well. Socioeconomic status is an important factor in many aspects of living as in academic achievement as well. Problem in this research paper was to examine whether there are differences between children from different socio-economic status (level of education of parents and between children from villages and towns, on Readiness for school tests. The sample was constituted 296 kids, half from villages, and half from towns in Bosnia and Herzegovina. Tests that were used are: Differences test, Similarities test, Numerical test, Trace test, Knowledge Test, Questionnaire for measuring socio-emotional maturity, and Goodenough's Draw-a-Man Test. Results show that there are statistically significant differences between children from different socio-economic background. Children whose parents are low educated have lower results on Readiness for school test, comparing with children whose parents have finished high school or university level. There were differences between village and town children only on Goodenough's Draw-a-Man Test and on Similarity test, while on other instruments place of living was not important factor for achievement on Readiness for School Test.

  19. Iron nutrition and premenopausal women: effects of poor iron status on physical and neuropsychological performance.

    Science.gov (United States)

    McClung, James P; Murray-Kolb, Laura E

    2013-01-01

    Iron is a nutritionally essential trace element that functions through incorporation into proteins and enzymes, many of which contribute to physical and neuropsychological performance. Poor iron status, including iron deficiency (ID; diminished iron stores) and iron deficiency anemia (IDA; poor iron stores and diminished hemoglobin), affects billions of people worldwide. This review focuses on physical and neuropsychological outcomes associated with ID and IDA in premenopausal women, as the prevalence of ID and IDA is often greater in premenopausal women than other population demographics. Recent studies addressing the physiological effects of poor iron status on physical performance, including work productivity, voluntary activity, and athletic performance, are addressed. Similarly, the effects of iron status on neurological performance, including cognition, affect, and behavior, are summarized. Nutritional countermeasures for the prevention of poor iron status and the restoration of decrements in performance outcomes are described.

  20. Acceptance test for graphite components and construction status of HTTR

    International Nuclear Information System (INIS)

    Iyoku, T.; Ishihara, M.; Maruyama, S.; Shiozawa, S.; Tsuji, N.; Miki, T.

    1996-01-01

    In March, 1991, the Japan Atomic Energy Research Institute (JAERI) started to constructed the High Temperature engineering Test Reactor(HTTR) which is a 30-MW(thermal) helium gas-cooled reactor with a core composed of prismatic graphite blocks piled on the core support graphite structures. Two types of graphite materials are used in the HTTR. One is the garde IG-110, isotropic fine grain graphite, another is the grade PGX, medium-to-fine grained molded graphite. These materials were selected on the basis of the appropriate properties required by the HTTR reactor design. Industry-wide standards for an acceptance test of graphite materials used as main components of a nuclear reactor had not been established. The acceptance standard for graphite components of the HTTR, therefore, was drafted by JAERI and reviewed by specialists outside JAERI. The acceptance standard consists of the material testing, non-destructive examination such as the ultrasonic and eddy current testings, dimensional and visual inspections and assembly test. Ultrasonic and eddy current testings are applied to graphite logs to detect an internal flaw and to graphite components to detect a surface flaw, respectively. The assembly test is performed at the works, prior to their installation in the reactor pressure vessel, to examine fabricating precision of each component and alignment of piled-up structures. The graphite components of the HTTR had been tested on the basis of the acceptance standard. It was confirmed that the graphite manufacturing process was well controlled and high quality graphite components were provided to the HTTR. All graphite components except for the fuel graphite blocks are to be installed in the reactor pressure vessel of the HTTR in September 1995. The paper describes the construction status of the HTTR focusing on the graphite components. The acceptance test results are also presented in this paper. (author). Figs

  1. Percentile Values for Running Sprint Field Tests in Children Ages 6-17 Years: Influence of Weight Status

    Science.gov (United States)

    Castro-Pinero, Jose; Gonzalez-Montesinos, Jose Luis; Keating, Xiaofen D.; Mora, Jesus; Sjostrom, Michael; Ruiz, Jonatan R.

    2010-01-01

    The aim of this study was to provide percentile values for six different sprint tests in 2,708 Spanish children (1,234 girls) ages 6-17.9 years. We also examined the influence of weight status on sprint performance across age groups, with a focus on underweight and obese groups. We used the 20-m, 30-m, and 50-m running sprint standing start and…

  2. General Health Status, Music Performance Anxiety, and Coping Methods of Musicians Working in Turkish State Symphony Orchestras: A Cross-Sectional Study.

    Science.gov (United States)

    Topoğlu, Onur; Karagülle, Derya; Keskin, Tuba U; Abacigil, Filiz; Okyay, Pinar

    2018-06-01

    This study assessed the general health, music performance anxiety (MPA), and coping methods of musicians working in six state orchestras in Turkey. All musicians working in the state symphony orchestras (n=384) were invited to participate in the study. In face-to-face interviews, the authors administered a questionnaire, which consisted of five sections: sociodemographic information, history of musical performance, health status, general health questionnaire-12 (GHQ-12), and MPA scale. Mann-Whitney U-test, Student's t-test, and Spearman's correlation test were used to analyze the questionnaire data. The 220 musicians who participated included 121 (55%) males and 99 (45%) females, with a mean age of 42.4±11.3 yrs. For musculoskeletal symptoms, 87.6% reported at least one symptom with the most common being pain. For general health status, the GHQ-12 showed 64% of musicians were at low risk, 18.7% at moderate risk, and 17.3% at high risk in terms of mental health. The prevalence of MPA before or during performance was 81.8%, and 60% of musicians stated that performance anxiety negatively affected their performances. Results indicate that musicians working in Turkish state symphony orchestras encounter numerous health problems (tinnitus, hearing loss, musculoskeletal symptoms, etc.) due to their profession. No specific health support is provided, especially education and health service provision.

  3. Status of irradiation testing and PIE of MOX (Pu-containing) fuel

    International Nuclear Information System (INIS)

    Dimayuga, F.C.; Zhou, Y.N.; Ryz, M.A.

    1995-01-01

    This paper describes AECL's mixed oxide (MOX) fuel-irradiation and post-irradiation examination (PIE) program. Post-irradiation examination results of two major irradiation experiments involving several (U, Pu)O 2 fuel bundles are highlighted. One experiment involved bundles irradiated to burnups ranging fro 400 to 1200 MWh/kgHe in the Nuclear Power Demonstration (NPD) reactor. The other experiment consisted of several (U, Pu)O 2 bundles irradiated to burnups of up to 500 Mwh/kgHe in the National Research Universal (NRU) reactor. Results of these experiments demonstrate the excellent performance of CANDU MOX fuel. This paper also outlines the status of current MOX fuel irradiation tests, including the irradiation of various (U, Pu)O 2 bundles. The strategic importance of MOX fuel to CANDU fuel-cycle flexibility is discussed. (author)

  4. STATUS BERKELANJUTAN KOTA TANGERANG SELATAN-BANTEN DENGAN MENGGUNAKAN KEY PERFORMANCE INDICATORS (Sustainable Status of South Tangerang City-Banten Using Key Performance Indicators

    Directory of Open Access Journals (Sweden)

    Heri Apriyanto

    2015-07-01

    Full Text Available ABSTRAK Pembangunan kota yang tidak terkendali akan mengakibatkan tekanan terhadap lingkungan dan beban masyarakat meningkat, sebaliknya degradasi lingkungan akan mengakibatkan pembatasan pengembangan ekonomi dan penurunan kualitas hidup. Guna mencegah terjadinya dampak-dampak negatif, maka diperlukan prinsip-prinsip pembangunan kota yang berkelanjutan. Evaluasi terhadap pelaksanan pembangunan kota yang berkelanjutan perlu dilakukan untuk mengetahui apakah pembangunan suatu kota sudah atau belum/tidak berkelanjutan. Penelitian ini bertujuan untuk menyusun Key Performance Indicators (KPI guna menilai status pembangunan kota berkelanjutan. Perumusan KPI ini dilakukan dengan pendekatan Analytic Hierarchy Process (AHP. KPI yang dihasilkan terdiri dari 21 indikator dan 9 elemen dari 3 pilar pembangunan berkelanjutan (ekonomi, sosial, dan lingkungan. Implementasi KPI dilakukan untuk pengukuran status keberlanjutan Kota Tangerang Selatan. Hasil pengukuran menunjukkan bahwa kota ini termasuk dalam tahap awal pembangunan berkelanjutan. Secara umum perkembangan ekonomi dan sosial relatif cukup baik, namun tidak demikian dengan kondisi lingkungannya. ABSTRACT Uncontrolled urban development will result in pressure on the environment and the burden of the people. On the contrary, environmental degradation will lead to restricted economic development and decreased quality of life. In order to prevent negative impacts, it is necessary to implement the principles of sustainable city development. Evaluation of the implementation of sustainable city development is needed to determine whether the development of a city is sustainable or not. This study aimed to develop Key Performance Indicators (KPI to assess the status of sustainable city development. The formulation of KPI is done with Analytic Hierarchy Process (AHP. KPI generated consists of 21 indicators and 9 elements of the 3 pillars of sustainable development (economic, social, and environmental

  5. The performance testing

    International Nuclear Information System (INIS)

    Mayr, A.

    1975-01-01

    Concerning the time-schedule of reactor performance tests they normally begin when suppliers or constructors have finished construction and made all necessary construction and coordinated tests. If the last-mentioned tests are conducted profoundly, they contribute substantially to a quick and simple carrying-out of the last performance tests and to the general quality of components and systems. At this stage all components of a system should be properly fixed, machinery, instruments and electrical components adjusted and calibrated, all set-points tested, electrical and other supply units in operation or ready to operate and all functions pretested. Just at this stage of the work most of the existing defects and failures of systems can be found. Remembering the fact that the difficulty of operation of complex systems results from detail problems, it is extremely useful to remove all things of this kind as soon as possible, at the latest at this time where it is done easily and normally quickly without influencing start-up-procedures of other systems or even of the total plant. (orig./TK) [de

  6. Development status of irradiation devices and instrumentation for material and nuclear fuel irradiation tests in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Sohn, Jae Min; Choo, Kee Nam [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-04-15

    The High flux Advanced Neutron Application ReactOr (HANARO), an open-tank-in-pool type reactor, is one of the multi-purpose research reactors in the world. Since the commencement of HANARO's operations in 1995, a significant number of experimental facilities have been developed and installed at HANARO, and continued efforts to develop more facilities are in progress. Owing to the stable operation of the reactor and its frequent utilization, more experimental facilities are being continuously added to satisfy various fields of study and diverse applications. The irradiation testing equipment for nuclear fuels and materials at HANARO can be classified into capsules and the Fuel Test Loop (FTL). Capsules for irradiation tests of nuclear fuels in HANARO have been developed for use under the dry conditions of the coolant and materials at HANARO and are now successfully utilized to perform irradiation tests. The FTL can be used to conduct irradiation testing of a nuclear fuel under the operating conditions of commercial nuclear power plants. During irradiation tests conducted using these capsules in HANARO, instruments such as the thermocouple, Linear Variable Differential Transformer (LVDT), small heater, Fluence Monitor (F/M) and Self-Powered Neutron Detector (SPND) are used to measure various characteristics of the nuclear fuel and irradiated material. This paper describes not only the status of HANARO and the status and perspective of irradiation devices and instrumentation for carrying out nuclear fuel and material tests in HANARO but also some results from instrumentation during irradiation tests

  7. Methodology of the Integrated Analysis of Company's Financial Status and Its Performance Results

    OpenAIRE

    Mackevičius, Jonas; Valkauskas, Romualdas

    2010-01-01

    Information about company's financial status and its performance results is very important for the objective evaluation of company's position in the market and competitive possibilities in the future. Such information is provided in the financial statement. It is important to apply and investigate this information properly. The methodology of company's financial status and performance results integrated analysis is recommended in this article. This methodology consists of these three elements...

  8. 40 CFR 60.8 - Performance tests.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Performance tests. 60.8 Section 60.8... PERFORMANCE FOR NEW STATIONARY SOURCES General Provisions § 60.8 Performance tests. (a) Except as specified in... conduct performance test(s) and furnish the Administrator a written report of the results of such...

  9. Uprated OMS Engine Status-Sea Level Testing Results

    Science.gov (United States)

    Bertolino, J. D.; Boyd, W. C.

    1990-01-01

    The current Space Shuttle Orbital Maneuvering Engine (OME) is pressure fed, utilizing storable propellants. Performance uprating of this engine, through the use of a gas generator driven turbopump to increase operating pressure, is being pursued by the NASA Johnson Space Center (JSC). Component level design, fabrication, and test activities for this engine system have been on-going since 1984. More recently, a complete engine designated the Integrated Component Test Bed (ICTB), was tested at sea level conditions by Aerojet. A description of the test hardware and results of the sea level test program are presented. These results, which include the test condition operating envelope and projected performance at altitude conditions, confirm the capability of the selected Uprated OME (UOME) configuration to meet or exceed performance and operational requirements. Engine flexibility, demonstrated through testing at two different operational mixture ratios, along with a summary of projected Space Shuttle performance enhancements using the UOME, are discussed. Planned future activities, including ICTB tests at simulated altitude conditions, and recommendations for further engine development, are also discussed.

  10. GRAPE EXTRACT IMPROVES ANTIOXIDANT STATUS AND PHYSICAL PERFORMANCE IN ELITE MALE ATHLETES

    Directory of Open Access Journals (Sweden)

    Sophie Lafay

    2009-09-01

    Full Text Available Excessive physical exercise overproduces reactive oxygen species. Even if elite sportsmen increase their antioxidant status by regular physical training, during the competition period, this improvement is not sufficient to limit free radical production which could be detrimental to the body. The aim of this randomized, double-blind, placebo controlled, and crossover study on 20 elite sportsmen (handball = 10, basketball = 5, sprint = 4, and volleyball = 1 during the competition period was to determine if the consumption of a grape extract (GE; Vitis vinifera L. was able to improve the parameters related to (i anti-oxidative status and oxidative stress and (ii physical performance. Specific biomarkers of antioxidant capacity, oxidative stress, skeletal cell muscle damage, and other general biomarkers were determined in plasma and urine before (D0 and after one month (D30 of placebo or GE supplementation (400mg·d-1. Effort tests were conducted using the Optojump® system, which allows determining the total physical performance (EnRJ45, explosive power (RJ110, and fatigue (RJL5. The plasma ORAC value was not modified in the placebo group; however, GE increased the ORAC value compared to the placebo at D30 (14 966+/-335 vs 14 242+/-339 µmol Teq·L-1; p < 0.05. The plasma FRAP value was significantly reduced in the placebo group, but not in the GE group. Therefore, GE limited the reduction of FRAP compared to the placebo at D30 (1 053.7+/-31.5 vs 993.7+/-26.7 µmol Teq·L-1; p < 0.05. Urinary isoprostane values were increased in the placebo group, but were not modified in the GE group. Consequently, GE limited the production of isoprostanes compared to the placebo at D30 (1.24+/-0.12 vs 1.26+/-0.13 ng·mg-1 creatinine; p < 0.05. GE administration, compared to the placebo at D30, reduced the plasmatic creatine phosphokinase concentration (CPK, 695.7+/-177.0 vs 480.0+/-81.1 IU·L-1, p = 0.1 and increased hemoglobin levels (Hb, 14.5+/-0.2 vs 14

  11. HEALTH INDICATORS IN SCHOOL: ASSESSMENT OF NUTRITIONAL STATUS AND MOTOR PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Andressa Ribeiro Contreira

    2013-11-01

    Full Text Available Objective: This study aimed to investigate the relationship among motor performance and nutritional status in students. Methods: Attended by 27 adolescents of both sexes, aged between 11-13 years (average 11.74 ± 0.70 years from a private school in Florianópolis/SC. The motor performance was assessed using the MABC-2. For assess the nutritional status was used the BMI calculus. Results: Among 27 participants, 6 had a risk / indicative of motor difficulties and 9 had overweight. The vast majority of participants had adequate height for age. There was negative significant statistically correlation, but moderate, among BMI and total performance in the MABC-2, indicating that as higher the BMI, worse is the motor performance. Conclusion: Based on these results and the literature, it is suggested that in addition to the identification of children with overweight and motor difficulties, programs targeted physical activity and motor interventions are implemented, especially in the school environment, aiming to maintain the health conditions.

  12. PIP-II Injector Test: Challenges and Status

    Energy Technology Data Exchange (ETDEWEB)

    Derwent, P. F. [Fermilab; Carneiro, J. P. [Fermilab; Edelen, J. [Fermilab; Lebedev, V. [Fermilab; Prost, L. [Fermilab; Saini, A. [Fermilab; Shemyakin, A. [Fermilab; Steimel, J. [Fermilab

    2016-10-04

    The Proton Improvement Plan II (PIP-II) at Fermilab is a program of upgrades to the injection complex. At its core is the design and construction of a CW-compatible, pulsed H- superconducting RF linac. To validate the concept of the front-end of such machine, a test accelerator known as PIP-II Injector Test is under construction. It includes a 10mA DC, 30 keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV CW RFQ, followed by a Medium Energy Beam Transport (MEBT) that feeds the first of 2 cryomodules increasing the beam energy to about 25 MeV, and a High Energy Beam Transport section (HEBT) that takes the beam to a dump. The ion source, LEBT, RFQ, and initial version of the MEBT have been built, installed, and commissioned. This report presents the overall status of the Injector Test warm front end, including results of the beam commissioning through the installed components, and progress with SRF cryomodules and other systems.

  13. Personality and job performance: test of the mediating effects of motivation among sales representatives.

    Science.gov (United States)

    Barrick, Murray R; Stewart, Greg L; Piotrowski, Mike

    2002-02-01

    Research shows consistent relations between personality and job performance. In this study the authors develop and test a model of job performance that examines the mediating effects of cognitive-motivational work orientations on the relationships between personality traits and performance in a sales job (N = 164). Covariance structural analyses revealed proximal motivational variables to be influential mechanisms through which distal personality traits affect job performance. Specifically, striving for status and accomplishment mediate the effects of Extraversion and Conscientiousness on ratings of sales performance. Although Agreeableness was related to striving for communion, neither Agreeableness nor communion striving was related to success in this sales job. The importance of the proposed motivational orientations model is discussed.

  14. Variations in Oncologist Recommendations for Chemotherapy for Stage IV Lung Cancer: What Is the Role of Performance Status?

    Science.gov (United States)

    Tisnado, Diana; Malin, Jennifer; Kahn, Katherine; Landrum, Mary Beth; Fletcher, Robert; Klabunde, Carrie; Clauser, Steven; Rogers, Selwyn O; Keating, Nancy L

    2016-07-01

    Chemotherapy prolongs survival in patients with advanced non-small-cell lung cancer. However, few studies have included patients with poor performance status. This study examined rates of oncologists' recommendations for chemotherapy by patient performance status and symptoms and how physician characteristics influence chemotherapy recommendations. We surveyed medical oncologists involved in the care of a population-based cohort of patients with lung cancer from the CanCORS (Cancer Care Outcomes Research and Surveillance) study. Physicians were queried about their likelihood to recommend chemotherapy to patients with stage IV lung cancer with varying performance status (Eastern Cooperative Oncology Group performance status 0 [good] v 3 [poor]) and presence or absence of tumor-related pain. Repeated measures logistic regression was used to estimate the independent associations of patients' performance status and symptoms and physicians' demographic and practice characteristics with chemotherapy recommendations. Nearly all physicians (adjusted rate, 97% to 99%) recommended chemotherapy for patients with good performance status, and approximately half (adjusted rate, 38% to 53%) recommended chemotherapy for patients with poor performance status (P factors, physician and practice characteristics were less strongly associated with chemotherapy recommendations in adjusted analyses. Strong consensus among oncologists exists for chemotherapy in patients with advanced non-small-cell lung cancer and good performance status. However, the relatively high rate of chemotherapy recommendations for patients with poor performance status despite the unfavorable risk-benefit profile highlights the need for ongoing work to define high-value care in oncology and to implement and evaluate strategies to align incentives for such care. Copyright © 2016 by American Society of Clinical Oncology.

  15. the relationship of birth status and early reproductive performance ...

    African Journals Online (AJOL)

    The effectiveness of selection for improvement in reproductive performance of sheep depends on measure- ment at any early age. For this reason selection of rams and ewes on their birth status, (single or twin), (Kennedy,. 1967; Turner, Hayman, Triffitt and Prunster, 1969), and ewes having multiple births during their first or ...

  16. Slow recovery of blood glucose in the insulin tolerance test during the prepartum transition period negatively impacts the nutritional status and reproductive performance postpartum of dairy cows.

    Science.gov (United States)

    Lee, Hsu-Hsun; Kida, Katsuya; Miura, Ryotaro; Inokuma, Hisashi; Miyamoto, Akio; Kawashima, Chiho; Haneda, Shingo; Miyake, Yoh-Ichi; Matsui, Motozumi

    2012-04-01

    In peripartum dairy cows, insulin resistance (IR) increases to adjust the direction of energy to lactation after calving. To investigate the effect of prepartum IR on postpartum reproductive performance, the insulin tolerance test (ITT) was applied to 15 cows at 3 weeks (Pre21) and 10 days (Pre10) before the predicted calving date. Blood glucose area under the curve (AUC(glu)) within 120 min after administration of 0.05 IU/kg-BW insulin was calculated. The occurrence of first ovulation, days to first artificial insemination (AI) and first AI conception rate were recorded. Nutritional status postpartum was evaluated by blood chemical analysis. Based on AUC(glu) changes from Pre21 to Pre10, cows were classified into either the AUC-up group (AUC(glu) increase, n=5) or the AUC-down group (AUC(glu) decrease, n=10). There was no difference in the decrease in blood glucose at 30 min after insulin injection between groups, although glucose recovery from 30 to 60 min during the ITT was slow at Pre10 in the AUC-up group. The AUC-up group had a higher number of days to first AI and high glucose, total protein, globulin, γ-glutamyltransferase, triacylglycerol levels and a low albumin-globulin ratio at the 14th day postpartum. The present study infers that prepartum slow glucose recovery rather than insulin sensitivity might increase the potential for subclinical health problems postpartum and thus suppress reproductive performance. During the prepartum transition period, glucose dynamics in the ITT can be considered as a new indicator for the postpartum metabolic status and reproductive performance of dairy cows.

  17. Status of the Moderator Circulation Tests at Korea Atomic Energy Research Institute

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoungtae; Rhee, Bowook; Cha, Jaeeun; Choi, Hwalim [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The scaling analysis produced the design parameters of the MCT facility, and the manufacturing process is ongoing. The application of the optical fluid measurements to the MCT was preliminary tested by small scale test models. The various flow patterns arising from a complex interaction between the buoyancy and inertia forces can be simulated in the MCT facility. In addition, the experimental results will be compared with the CFD results. The Korea Atomic Energy Research Institute (KAERI) started experimental research on moderator circulation as one of its national R and D research programs in 2012. In the present paper, we introduce a scaling analysis performed to extend the scaling criteria suitable for reproducing thermal-hydraulic phenomena in a scaled-down CANDU-6 moderator tank, 1/40 and 1/8 small-scale model tests to identify the potential problems of the flow visualization and measurement in the main 1/4 scale MCT (Moderator Circulation Test) facility, a manufacturing status of the 1/4 scale moderator tank, and preliminary CFD analysis results to determine the flow, thermal, and heating boundary conditions with which the various flow patterns expected in the prototype CANDU-6 moderator tank can be reproduced in the experiment. KAERI has launched an experimental program for moderator circulation in a CANDU6 reactor.

  18. The U.S. Department of Energy Laboratory Accreditation Program for testing the performance of extremity dosimetry systems: a summary of the program status

    International Nuclear Information System (INIS)

    Cummings, F.M.; Carlson, R.D.; Gesell, T.F.; Loesch, R.M.

    1992-01-01

    In 1986, The U.S. Department of Energy (DOE) implemented a program to test the performance of its personnel whole-body dosimetry systems. This program was the DOE Laboratory Accreditation Program (DOELAP). The program parallels the performance testing program specified in the American National Standard for Dosimetry - Personnel Dosimetry Performance -Criteria for Testing (ANSI N13.11-1983), but also addresses the additional dosimetry needs of DOE facilities. As an extension of the whole-body performance testing program, the DOE is now developing a program to test the performance of personnel extremity dosimetry systems. The draft DOE standard for testing extremity dosimetry systems is much less complex than the whole-body dosimetry standard and reflects the limitations imposed on extremity dosimetry by dosimeter design and irradiation geometry. A pilot performance test session has been conducted to evaluate the proposed performance-testing standard. (author)

  19. Visual determinants of reduced performance on the Stroop color-word test in normal aging individuals.

    Science.gov (United States)

    van Boxtel, M P; ten Tusscher, M P; Metsemakers, J F; Willems, B; Jolles, J

    2001-10-01

    It is unknown to what extent the performance on the Stroop color-word test is affected by reduced visual function in older individuals. We tested the impact of common deficiencies in visual function (reduced distant and close acuity, reduced contrast sensitivity, and color weakness) on Stroop performance among 821 normal individuals aged 53 and older. After adjustment for age, sex, and educational level, low contrast sensitivity was associated with more time needed on card I (word naming), red/green color weakness with slower card 2 performance (color naming), and reduced distant acuity with slower performance on card 3 (interference). Half of the age-related variance in speed performance was shared with visual function. The actual impact of reduced visual function may be underestimated in this study when some of this age-related variance in Stroop performance is mediated by visual function decrements. It is suggested that reduced visual function has differential effects on Stroop performance which need to be accounted for when the Stroop test is used both in research and in clinical settings. Stroop performance measured from older individuals with unknown visual status should be interpreted with caution.

  20. The Cost of Collaborating with Climbers of Status Hierarchies

    DEFF Research Database (Denmark)

    Andersen, Kristina Vaarst; Mors, Marie Louise; Jeppesen, Jacob

    Status provides preferential access to resources, as well as favorable judgment, which in turn may lead to increases in performance. Prior work has established that such benefits even spill over between collaboration partners, thus allowing collaboration partners of high status individuals to bask...... individual performance. We argue that collaboration partners’ increased status may divert their allocation of effort and focus to other projects. This in turn may lead to a negative spillover effect for individual performance. These arguments are tested using unique data on scientists collaborating on papers...... in their reflected glory and enjoy status related benefits. Yet, we still know relatively little about the underlying mechanisms that affect how individual performance is affected by changes in the status of collaboration partners. In this paper, we analyze how collaboration partners’ status increase affects...

  1. Adolescent Weight Status and Self-Reported School Performance in South Korea

    Directory of Open Access Journals (Sweden)

    Young Kyung Do

    2011-01-01

    Full Text Available Using a nationally representative sample of 142 783 middle school (13–15 years old and high school (16–18 years old students in South Korea, this study examined whether (1 overweight and obesity are more likely to be associated with lower self-reported school performance; (2 overweight and obese students are more likely to enrol in a vocational high school as opposed to a general high school; (3 the association between obesity and poorer self-reported school performance is mediated through body image stress and health status. We found that excess weight was negatively associated with self-reported school performance among middle and general high school students, and that obese students had a higher probability of being enrolled in a vocational over a general high school. We did not find strong evidence on the mediating role of body image stress and health status.

  2. The Influence of Chronic and Situational Social Status on Stereotype Susceptibility.

    Science.gov (United States)

    Pillaud, Vincent; Rigaud, David; Clémence, Alain

    2015-01-01

    We tested whether stereotypical situations would affect low-status group members' performance more strongly than high-status group members'. Experiment 1 and 2 tested this hypothesis using gender as a proxy of chronic social status and a gender-neutral task that has been randomly presented to favor boys (men superiority condition), favor girls (women superiority condition), or show no gender preference (control condition). Both experiments found that women's (Experiment 1) and girls' performance (Experiment 2) suffered more from the evoked stereotypes than did men's and boys' ones. This result was replicated in Experiment 3, indicating that short men (low-status group) were more affected compared to tall men (high-status group). Additionally, men were more affected compared to women when they perceived height as a threat. Hence, individuals are more or less vulnerable to identity threats as a function of the chronic social status at play; enjoying a high status provides protection and endorsing a low one weakens individual performance in stereotypical situations.

  3. The Influence of Chronic and Situational Social Status on Stereotype Susceptibility

    Science.gov (United States)

    Pillaud, Vincent; Rigaud, David; Clémence, Alain

    2015-01-01

    We tested whether stereotypical situations would affect low-status group members' performance more strongly than high-status group members'. Experiment 1 and 2 tested this hypothesis using gender as a proxy of chronic social status and a gender-neutral task that has been randomly presented to favor boys (men superiority condition), favor girls (women superiority condition), or show no gender preference (control condition). Both experiments found that women’s (Experiment 1) and girls’ performance (Experiment 2) suffered more from the evoked stereotypes than did men's and boys’ ones. This result was replicated in Experiment 3, indicating that short men (low-status group) were more affected compared to tall men (high-status group). Additionally, men were more affected compared to women when they perceived height as a threat. Hence, individuals are more or less vulnerable to identity threats as a function of the chronic social status at play; enjoying a high status provides protection and endorsing a low one weakens individual performance in stereotypical situations. PMID:26645829

  4. The Influence of Chronic and Situational Social Status on Stereotype Susceptibility.

    Directory of Open Access Journals (Sweden)

    Vincent Pillaud

    Full Text Available We tested whether stereotypical situations would affect low-status group members' performance more strongly than high-status group members'. Experiment 1 and 2 tested this hypothesis using gender as a proxy of chronic social status and a gender-neutral task that has been randomly presented to favor boys (men superiority condition, favor girls (women superiority condition, or show no gender preference (control condition. Both experiments found that women's (Experiment 1 and girls' performance (Experiment 2 suffered more from the evoked stereotypes than did men's and boys' ones. This result was replicated in Experiment 3, indicating that short men (low-status group were more affected compared to tall men (high-status group. Additionally, men were more affected compared to women when they perceived height as a threat. Hence, individuals are more or less vulnerable to identity threats as a function of the chronic social status at play; enjoying a high status provides protection and endorsing a low one weakens individual performance in stereotypical situations.

  5. Inspection system performance test procedure

    International Nuclear Information System (INIS)

    Jensen, C.E.

    1995-01-01

    This procedure establishes requirements to administer a performance demonstration test. The test is to demonstrate that the double-shell tank inspection system (DSTIS) supplied by the contractor performs in accordance with the WHC-S-4108, Double-Shell Tank Ultrasonic Inspection Performance Specification, Rev. 2-A, January, 1995. The inspection system is intended to provide ultrasonic (UT) and visual data to determine integrity of the Westinghouse Hanford Company (WHC) site underground waste tanks. The robotic inspection system consists of the following major sub-systems (modules) and components: Mobile control center; Deployment module; Cable management assembly; Robot mechanism; Ultrasonic testing system; Visual testing system; Pneumatic system; Electrical system; and Control system

  6. Status of ANC-linked HIV counseling and testing as an intervention ...

    African Journals Online (AJOL)

    Status of ANC-linked HIV counseling and testing as an intervention for PMTCT in public health facilities in Addis Ababa: quality of HIV counseling given to pregnant women for PMTCT. ... AJOL African Journals Online. HOW TO USE AJOL.

  7. Double-shell tank integrity assessments ultrasonic test equipment performance test

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, D.C.

    1996-09-26

    A double-shell tank (DST) inspection (DSTI) system was performance tested over three months until August 1995 at Pittsburgh, Pennsylvania, completing a contract initiated in February 1993 to design, fabricate, and test an ultrasonic inspection system intended to provide ultrasonic test (UT) and visual data to determine the integrity of 28 DSTs at Hanford. The DSTs are approximately one-million-gallon underground radioactive-waste storage tanks. The test was performed in accordance with a procedure (Jensen 1995) that included requirements described in the contract specification (Pfluger 1995). This report documents the results of tests conducted to evaluate the performance of the DSTI system against the requirements of the contract specification. The test of the DSTI system also reflects the performance of qualified personnel and operating procedures.

  8. Kolmogorov-Smirnov statistical test for analysis of ZAP-70 expression in B-CLL, compared with quantitative PCR and IgV(H) mutation status.

    Science.gov (United States)

    Van Bockstaele, Femke; Janssens, Ann; Piette, Anne; Callewaert, Filip; Pede, Valerie; Offner, Fritz; Verhasselt, Bruno; Philippé, Jan

    2006-07-15

    ZAP-70 has been proposed as a surrogate marker for immunoglobulin heavy-chain variable region (IgV(H)) mutation status, which is known as a prognostic marker in B-cell chronic lymphocytic leukemia (CLL). The flow cytometric analysis of ZAP-70 suffers from difficulties in standardization and interpretation. We applied the Kolmogorov-Smirnov (KS) statistical test to make analysis more straightforward. We examined ZAP-70 expression by flow cytometry in 53 patients with CLL. Analysis was performed as initially described by Crespo et al. (New England J Med 2003; 348:1764-1775) and alternatively by application of the KS statistical test comparing T cells with B cells. Receiver-operating-characteristics (ROC)-curve analyses were performed to determine the optimal cut-off values for ZAP-70 measured by the two approaches. ZAP-70 protein expression was compared with ZAP-70 mRNA expression measured by a quantitative PCR (qPCR) and with the IgV(H) mutation status. Both flow cytometric analyses correlated well with the molecular technique and proved to be of equal value in predicting the IgV(H) mutation status. Applying the KS test is reproducible, simple, straightforward, and overcomes a number of difficulties encountered in the Crespo-method. The KS statistical test is an essential part of the software delivered with modern routine analytical flow cytometers and is well suited for analysis of ZAP-70 expression in CLL. (c) 2006 International Society for Analytical Cytology.

  9. LFK, FORTRAN Application Performance Test

    International Nuclear Information System (INIS)

    McMahon, F.H.

    1991-01-01

    1 - Description of program or function: LFK, the Livermore FORTRAN Kernels, is a computer performance test that measures a realistic floating-point performance range for FORTRAN applications. Informally known as the Livermore Loops test, the LFK test may be used as a computer performance test, as a test of compiler accuracy (via checksums) and efficiency, or as a hardware endurance test. The LFK test, which focuses on FORTRAN as used in computational physics, measures the joint performance of the computer CPU, the compiler, and the computational structures in units of Mega-flops/sec or Mflops. A C language version of subroutine KERNEL is also included which executes 24 samples of C numerical computation. The 24 kernels are a hydrodynamics code fragment, a fragment from an incomplete Cholesky conjugate gradient code, the standard inner product function of linear algebra, a fragment from a banded linear equations routine, a segment of a tridiagonal elimination routine, an example of a general linear recurrence equation, an equation of state fragment, part of an alternating direction implicit integration code, an integrate predictor code, a difference predictor code, a first sum, a first difference, a fragment from a two-dimensional particle-in-cell code, a part of a one-dimensional particle-in-cell code, an example of how casually FORTRAN can be written, a Monte Carlo search loop, an example of an implicit conditional computation, a fragment of a two-dimensional explicit hydrodynamics code, a general linear recurrence equation, part of a discrete ordinates transport program, a simple matrix calculation, a segment of a Planck distribution procedure, a two-dimensional implicit hydrodynamics fragment, and determination of the location of the first minimum in an array. 2 - Method of solution: CPU performance rates depend strongly on the maturity of FORTRAN compiler machine code optimization. The LFK test-bed executes the set of 24 kernels three times, resetting the DO

  10. Performance comparison of machine learning methods for prognosis of hormone receptor status in breast cancer tissue samples.

    Science.gov (United States)

    Kalinli, Adem; Sarikoc, Fatih; Akgun, Hulya; Ozturk, Figen

    2013-06-01

    We examined the classification and prognostic scoring performances of several computer methods on different feature sets to obtain objective and reproducible analysis of estrogen receptor status in breast cancer tissue samples. Radial basis function network, k-nearest neighborhood search, support vector machines, naive bayes, functional trees, and k-means clustering algorithm were applied to the test datasets. Several features were employed and the classification accuracies of each method for these features were examined. The assessment results of the methods on test images were also experimentally compared with those of two experts. According to the results of our experimental work, a combination of functional trees and the naive bayes classifier gave the best prognostic scores indicating very good kappa agreement values (κ=0.899 and κ=0.949, p<0.001) with the experts. This combination also gave the best dichotomization rate (96.3%) for assessment of estrogen receptor status. Wavelet color features provided better classification accuracy than Laws texture energy and co-occurrence matrix features. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. Estimates of Job Performance for Applicants Differing in Gender, Marital and Parental Status.

    Science.gov (United States)

    Borges, Marilyn A.; Clothier, Tamara A.

    Women and men tend to be defined by their marital and parental status; thus, these factors may be crucial in understanding societal attitudes toward working men and women. The influence of marital and parental status on perceived job performance was investigated with a college undergraduate sample (N=128). From paragraph descriptions that varied…

  12. Radioactive material packaging performance testing

    International Nuclear Information System (INIS)

    Romano, T.; Cruse, J.M.

    1991-02-01

    To provide uniform packaging of hazardous materials on an international level, the United Nations has developed packaging recommendations that have been implemented worldwide. The United Nations packaging recommendations are performance oriented, allowing for a wide variety of package materials and systems. As a result of this international standard, efforts in the United States are being directed toward use of performance-oriented packaging and elimination of specification (designed) packaging. This presentation will focus on trends, design evaluation, and performance testing of radioactive material packaging. The impacts of US Department of Transportation Dockets HM-181 and HM-169A on specification and low-specific activity radioactive material packaging requirements are briefly discussed. The US Department of Energy's program for evaluating radioactive material packings per US Department of Transportation Specification 7A Type A requirements, is used as the basis for discussing low-activity packaging performance test requirements. High-activity package testing requirements are presented with examples of testing performed at the Hanford Site that is operated by Westinghouse Hanford Company for the US Department of Energy. 5 refs., 2 tabs

  13. So Young and Already Victims of Stereotype Threat: Socio-Economic Status and Performance of 6 to 9 Years Old Children on Raven's Progressive Matrices

    Science.gov (United States)

    Desert, Michel; Preaux, Marie; Jund, Robin

    2009-01-01

    The aim of this study was to verify whether children from low socio-economic status (SES) are victims of stereotype threat. Children in first grade (6 to 7 years old) and third grade (8 to 9 years old) performed Raven's progressive matrices, an intellectual ability test commonly used by psychologists. The test was presented either with the…

  14. Less Common Etiologies of Status Epilepticus

    Science.gov (United States)

    Bleck, Thomas P

    2010-01-01

    Status epilepticus is treated as a neurologic emergency and only later are the potential etiologies assessed. While sometimes the cause for status epilepticus is apparent (e.g., antiepileptic drug withdrawal), all too often it is not identified, even after extensive diagnostic testing has been performed. With emphasis on the less-common etiologies, this review will cover various probable and known causes of status epilepticus among adults, children, and those patients with refractory epilepsy. PMID:20231917

  15. Status report on ESF-related prototype testing

    International Nuclear Information System (INIS)

    Oliver, R.D.; Kalia, H.N.

    1992-12-01

    This report provides information on the Prototype Testing performed in the G-Tunnel on the Nevada Test Site by the Yucca Mountain Project form April 1988 to November 1989. The Testing Program was implemented to ensure that the Exploratory Shaft Facility (ESF) tests can be completed in the time available and to develop instruments, equipment, and procedures so the ESF tests can collect reliable and representative site characterization data. This report summarizes the ESF prototype tests and presents preliminary results

  16. Knowledge of carrier status and barriers to testing among mothers of sons with Duchenne or Becker muscular dystrophy.

    Science.gov (United States)

    Bogue, Lauren; Peay, Holly; Martin, Ann; Lucas, Ann; Ramchandren, Sindhu

    2016-12-01

    Our study objective was to survey female carriers for Duchenne and Becker muscular dystrophy to identify barriers to carrier testing and the impact of carrier risk knowledge on cardiac and reproductive health management. We surveyed women who have or had biological sons with Duchenne or Becker muscular dystrophy and were enrolled in the US DuchenneConnect patient registry, with questions assessing knowledge of carrier status and recurrence risk, knowledge of care standards for carriers, and barriers to testing. Of the 182 eligible respondents, 25% did not know their carrier status and 14% incorrectly classified themselves as not at risk. Cost of testing was the most commonly identified barrier to testing. Women reporting unknown carrier status were 13 times as likely to express uncertainty regarding their recurrence risk compared to women reporting positive carrier status. 37% of women at an increased risk for cardiomyopathy had never had an echocardiogram. Women who were certain of their positive carrier status were twice as likely to have had an echocardiogram in the last five years compared to women with unknown carrier status. Future research on reducing barriers to counseling and carrier testing, such as cost, may improve care standard adherence. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Uniform peanut performance test 2017

    Science.gov (United States)

    The Uniform Peanut Performance Tests (UPPT) are designed to evaluate the commercial potential of advanced breeding peanut lines not formally released. The tests are performed in ten locations across the peanut production belt. In this study, 2 controls and 14 entries were evaluated at 8 locations....

  18. Parental Socio-Economic Status, Self-Concept and Gender Differences on Students' Academic Performance in Borno State Colleges of Education: Implications for Counselling

    Science.gov (United States)

    Goni, Umar; Bello, S.

    2016-01-01

    This is a survey study, designed to determine gender differences and socio-economic status, self-concept on students' academic performance in Colleges of Education, Borno State: Implications for counselling. The study set two research objectives, answered two research questions and tested two research hypotheses. The target population of this…

  19. Performance analysis of spectrum sensing with multiple status changes in primary user traffic

    KAUST Repository

    Tang, Liang

    2012-06-01

    In this letter, the impact of primary user traffic with multiple status changes on the spectrum sensing performance is analyzed. Closed-form expressions for the probabilities of false alarm and detection are derived. Numerical results show that the multiple status changes of the primary user cause considerable degradation in the sensing performance. This degradation depends on the number of changes, the primary user traffic model, the primary user traffic intensity and the signal-to-noise ratio of the received signal. Numerical results also show that the amount of degradation decreases when the number of changes increases, and converges to a minimum sensing performance due to the limited sensing period and primary holding time. © 2012 IEEE.

  20. An objective measure of physical function of elderly outpatients. The Physical Performance Test.

    Science.gov (United States)

    Reuben, D B; Siu, A L

    1990-10-01

    Direct observation of physical function has the advantage of providing an objective, quantifiable measure of functional capabilities. We have developed the Physical Performance Test (PPT), which assesses multiple domains of physical function using observed performance of tasks that simulate activities of daily living of various degrees of difficulty. Two versions are presented: a nine-item scale that includes writing a sentence, simulated eating, turning 360 degrees, putting on and removing a jacket, lifting a book and putting it on a shelf, picking up a penny from the floor, a 50-foot walk test, and climbing stairs (scored as two items); and a seven-item scale that does not include stairs. The PPT can be completed in less than 10 minutes and requires only a few simple props. We then tested the validity of PPT using 183 subjects (mean age, 79 years) in six settings including four clinical practices (one of Parkinson's disease patients), a board-and-care home, and a senior citizens' apartment. The PPT was reliable (Cronbach's alpha = 0.87 and 0.79, interrater reliability = 0.99 and 0.93 for the nine-item and seven-item tests, respectively) and demonstrated concurrent validity with self-reported measures of physical function. Scores on the PPT for both scales were highly correlated (.50 to .80) with modified Rosow-Breslau, Instrumental and Basic Activities of Daily Living scales, and Tinetti gait score. Scores on the PPT were more moderately correlated with self-reported health status, cognitive status, and mental health (.24 to .47), and negatively with age (-.24 and -.18). Thus, the PPT also demonstrated construct validity. The PPT is a promising objective measurement of physical function, but its clinical and research value for screening, monitoring, and prediction will have to be determined.

  1. Watertrak, a computerized liquid waste treatment system status and performance monitoring program

    International Nuclear Information System (INIS)

    Vance, J.N.; Tafazzoli, M.M.

    1984-01-01

    Because of continuing problems in the radwaste system operations of a large number of plants currently operating, there is an increasing need to provide greater quantities of radwaste system information to plant operators and managers. Current and more complete information is required to enhance the operation and performance of the radwaste treatment systems, to assess the current system status, to plan for changing plant conditions and to diagnose actual or impending problems. The information needs include: real-time system status monitoring, equipment performance monitoring, report generation for operators and plant management, and training information. The nature and quantity of information required makes this program well-suited for a computer-aided engineering application

  2. 40 CFR 63.344 - Performance test requirements and test methods.

    Science.gov (United States)

    2010-07-01

    ... electroplating tanks or chromium anodizing tanks. The sampling time and sample volume for each run of Methods 306... Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test... Emissions From Decorative and Hard Chromium Electroplating and Anodizing Operations,” appendix A of this...

  3. Cognitive performance after mild traumatic brain injury: the impact of poor effort on test results and its relation to distress, personality and litigation.

    Science.gov (United States)

    Stulemeijer, Maja; Andriessen, Teuntje M J C; Brauer, Jolanda M P; Vos, Pieter E; Van Der Werf, Sieberen

    2007-03-01

    To compare consecutive Mild Traumatic Brain Injury (MTBI) patients with and without adequate effort on cognitive performance, litigation status, fatigue, distress and personality. (Neuro)psychological assessment was done 6 months post-injury in 110 patients from a cohort of 618 consecutive MTBI patients aged 18-60, who attended the emergency department of our level I trauma centre. Effort was tested with the Amsterdam Short Term Memory test. Thirty patients (27%) failed the effort test. Poor effort was associated with significantly poorer scores on seven out of eleven measures, covering all tested domains. Poor effort was associated with lower educational level and changes in work status, but not litigation. Furthermore, poor effort was related to high levels of distress, Type-D personality and fatigue. Even in a sample of non-referred MTBI patients, poor effort was common and was strongly associated with inferior test performance. These findings imply that effort testing should be part of all cognitive assessments, also outside mediolegal settings. Behavioural factors like distress and personality should be considered as potential threats to the validity of neuropsychological testing after MTBI.

  4. 45 CFR 170.465 - Revocation of authorized testing and certification body status.

    Science.gov (United States)

    2010-10-01

    ... INFORMATION TECHNOLOGY HEALTH INFORMATION TECHNOLOGY STANDARDS, IMPLEMENTATION SPECIFICATIONS, AND CERTIFICATION CRITERIA AND CERTIFICATION PROGRAMS FOR HEALTH INFORMATION TECHNOLOGY Temporary Certification Program for HIT § 170.465 Revocation of authorized testing and certification body status. (a) Type-1...

  5. Busted Butte Unsaturated Zone Transport Test: Fiscal Year 1998 Status Report Yucca Mountain Site Characterization Program Deliverable SPU85M4

    International Nuclear Information System (INIS)

    Bussod, G.Y.; Turin, H.J.; Lowry, W.E.

    1999-01-01

    This report describes the status of the Busted Butte Unsaturated Zone Transport Test (UZTT) and documents the progress of construction activities and site and laboratory characterization activities undertaken in fiscal year 1998. Also presented are predictive flow-and-transport simulations for Test Phases 1 and 2 of testing and the preliminary results and status of these test phases. Future anticipated results obtained from unsaturated-zone (UZ) transport testing in the Calico Hills Formation at Busted Butte are also discussed in view of their importance to performance assessment (PA) needs to build confidence in and reduce the uncertainty of site-scale flow-and-transport models and their abstractions for performance for license application. The principal objectives of the test are to address uncertainties associated with flow and transport in the UZ site-process models for Yucca Mountain, as identified by the PA working group in February 1997. These include but are not restricted to: (1) The effect of heterogeneities on flow and transport in unsaturated and partially saturated conditions in the Calico Hills Formation. In particular, the test aims to address issues relevant to fracture-matrix interactions and permeability contrast boundaries; (2) The migration behavior of colloids in fractured and unfractured Calico Hills rocks; (3) The validation through field testing of laboratory sorption experiments in unsaturated Calico Hills rocks; (4) The evaluation of the 3-D site-scale flow-and-transport process model (i.e., equivalent-continuum/dual-permeability/discrete-fracture-fault representations of flow and transport) used in the PA abstractions for license application; and (5) The effect of scaling from lab scale to field scale and site scale

  6. The health status of population in the regions boarding to Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Balmukhanov, S.B.; Raisova, G.K.; Balmukhanov, T.S.; Voronin, A.M.; Sandybaev, M.N.

    2002-01-01

    It is performed the detailed investigation the health status of Semipalatinsk region population affected by constant radioactive irradiation during 40 years. The special attention attached to such pathologies as cancer, congenial defects of development and pathologies of cardio-vascular and nervous systems. It is also characterized the children health status. (author)

  7. Stereotype Threat, Test Anxiety, and Mathematics Performance

    Science.gov (United States)

    Tempel, Tobias; Neumann, Roland

    2014-01-01

    We investigated the combined effects of stereotype threat and trait test anxiety on mathematics test performance. Stereotype threat and test anxiety interacted with each other in affecting performance. Trait test anxiety predicted performance only in a diagnostic condition that prevented stereotype threat by stereotype denial. A state measure of…

  8. The Effects of Solo Status on Women's and Men's Success: The Moderating Role of the Performance Context

    Science.gov (United States)

    Viallon, Marie-Laure; Martinot, Delphine

    2009-01-01

    A considerable body of research has shown that being the only representative of one's gender group (solo status) when performing an activity affects women more than men. The aim of our two experiments was to show that the performance context can moderate the effects of numerical status (majority vs. solo) on performance and that men can also be…

  9. Low-level radioactive waste management at the Nevada Test Site - Current status

    International Nuclear Information System (INIS)

    Becker, B.D.; Crowe, B.M.; Gertz, C.P.; Clayton, W.A.

    1999-01-01

    The performance objectives of the Department of Energy's Low-Level Radioactive Waste (LLW) disposal facilities located at the Nevada Test Site transcend those of any other radioactive waste disposal site in the US. Situated at the southern end of the Great Basin, 800 feet above the water table, the Area 5 Radioactive Waste Management Site (RWMS) has utilized a combination of engineered shallow land disposal cells and deep augured shafts to dispose a variety of waste streams. These include high volume low-activity wastes, classified materials, and high-specific-activity special case wastes. Twenty miles north of Area 5 is the Area 3 RWMS. Here bulk LLW disposal takes place in subsidence craters formed from underground testing of nuclear weapons. Earliest records indicate that documented LLW disposal activities have occurred at the Area 5 and Area 3 RWMS's since 1961 and 1968, respectively. However, these activities have only been managed under a formal program since 1978. This paper describes the technical attributes of the facilities, present and future capacities and capabilities, and provides a description of the process from waste approval to final disposition. The paper also summarizes the current status of the waste disposal operations

  10. Reliability and Validity of a Submaximal Warm-up Test for Monitoring Training Status in Professional Soccer Players.

    Science.gov (United States)

    Rabbani, Alireza; Kargarfard, Mehdi; Twist, Craig

    2018-02-01

    Rabbani, A, Kargarfard, M, and Twist, C. Reliability and validity of a submaximal warm-up test for monitoring training status in professional soccer players. J Strength Cond Res 32(2): 326-333, 2018-Two studies were conducted to assess the reliability and validity of a submaximal warm-up test (SWT) in professional soccer players. For the reliability study, 12 male players performed an SWT over 3 trials, with 1 week between trials. For the validity study, 14 players of the same team performed an SWT and a 30-15 intermittent fitness test (30-15IFT) 7 days apart. Week-to-week reliability in selected heart rate (HR) responses (exercise heart rate [HRex], heart rate recovery [HRR] expressed as the number of beats recovered within 1 minute [HRR60s], and HRR expressed as the mean HR during 1 minute [HRpost1]) was determined using the intraclass correlation coefficient (ICC) and typical error of measurement expressed as coefficient of variation (CV). The relationships between HR measures derived from the SWT and the maximal speed reached at the 30-15IFT (VIFT) were used to assess validity. The range for ICC and CV values was 0.83-0.95 and 1.4-7.0% in all HR measures, respectively, with the HRex as the most reliable HR measure of the SWT. Inverse large (r = -0.50 and 90% confidence limits [CLs] [-0.78 to -0.06]) and very large (r = -0.76 and CL, -0.90 to -0.45) relationships were observed between HRex and HRpost1 with VIFT in relative (expressed as the % of maximal HR) measures, respectively. The SWT is a reliable and valid submaximal test to monitor high-intensity intermittent running fitness in professional soccer players. In addition, the test's short duration (5 minutes) and simplicity mean that it can be used regularly to assess training status in high-level soccer players.

  11. Is the technical performance of young soccer players influenced by hormonal status, sexual maturity, anthropometric profile, and physical performance?

    Science.gov (United States)

    Moreira, Alexandre; Massa, Marcelo; Thiengo, Carlos R; Rodrigues Lopes, Rafael Alan; Lima, Marcelo R; Vaeyens, Roel; Barbosa, Wesley P; Aoki, Marcelo S

    2017-12-01

    The aim of this study was to examine the influence of hormonal status, anthropometric profile, sexual maturity level, and physical performance on the technical abilities of 40 young male soccer players during small-sided games (SSGs). Anthropometric profiling, saliva sampling, sexual maturity assessment (Tanner scale), and physical performance tests (Yo-Yo and vertical jumps) were conducted two weeks prior to the SSGs. Salivary testosterone was determined by the enzyme-linked immunosorbent assay method. Technical performance was determined by the frequency of actions during SSGs. Principal component analyses identified four technical actions of importance: total number of passes, effectiveness, goal attempts, and total tackles. A multivariate canonical correlation analysis was then employed to verify the prediction of a multiple dependent variables set (composed of four technical actions) from an independent set of variables, composed of testosterone concentration, stage of pubic hair and genitalia development, vertical jumps and Yo-Yo performance. A moderate-to-large relationship between the technical performance set and the independent set was observed. The canonical correlation was 0.75 with a canonical R 2 of 0.45. The highest structure coefficient in the technical performance set was observed for tackles (0.77), while testosterone presented the highest structure coefficient (0.75) for the variables of the independent set. The current data suggest that the selected independent set of variables might be useful in predicting SSG performance in young soccer players. Coaches should be aware that physical development plays a key role in technical performance to avoid decision-making mistakes during the selection of young players.

  12. Detection of acute deterioration in health status visit among COPD patients by monitoring COPD assessment test score

    Directory of Open Access Journals (Sweden)

    Pothirat C

    2015-02-01

    Full Text Available Chaicharn Pothirat, Warawut Chaiwong, Atikun Limsukon, Athavudh Deesomchok, Chalerm Liwsrisakun, Chaiwat Bumroongkit, Theerakorn Theerakittikul, Nittaya PhetsukDivision of Pulmonary, Critical Care and Allergy, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, ThailandBackground: The Chronic Obstructive Pulmonary Disease Assessment Test (CAT could play a role in detecting acute deterioration in health status during monitoring visits in routine clinical practice.Objective: To evaluate the discriminative property of a change in CAT score from a stable baseline visit for detecting acute deterioration in health status visits of chronic obstructive pulmonary disease (COPD patients.Methods: The CAT questionnaire was administered to stable COPD patients routinely attending the chest clinic of Chiang Mai University Hospital who were monitored using the CAT score every 1–3 months for 15 months. Acute deterioration in health status was defined as worsening or exacerbation. CAT scores at baseline, and subsequent visits with acute deterioration in health status were analyzed using the t-test. The receiver operating characteristic curve was performed to evaluate the discriminative property of change in CAT score for detecting acute deterioration during a health status visit.Results: A total of 354 follow-up visits were made by 140 patients, aged 71.1±8.4 years, with a forced expiratory volume in 1 second of 47.49%±18.2% predicted, who were monitored for 15 months. The mean CAT score change between stable baseline visits, by patients’ and physicians’ global assessments, were 0.05 (95% confidence interval [CI], -0.37–0.46 and 0.18 (95% CI, -0.23–0.60, respectively. At worsening visits, as assessed by patients, there was significant increase in CAT score (6.07; 95% CI, 4.95–7.19. There were also significant increases in CAT scores at visits with mild and moderate exacerbation (5.51 [95% CI, 4.39–6

  13. Differences in mathematics and science performance by economic status, gender, and ethnicity/race: A multiyear Texas statewide study

    Science.gov (United States)

    Anderson, Pamela Bennett

    Purpose. The purpose of the first study was to ascertain the extent to which differences were present in the STAAR Mathematics and Science test scores by Grade 5 and Grade 8 student economic status. The purpose of the second study was to examine differences in Grade 5 STAAR Mathematics and Science test performance by gender and by ethnicity/race (i.e., Asian, Black, Hispanic, and White). Finally, with respect to the third study in this journal-ready dissertation, the purpose was to investigate the STAAR Mathematics and Science test scores of Grade 8 students by gender and by ethnicity/race (i.e., Asian, Black, Hispanic, and White). Method. For this journal-ready dissertation, a non-experimental, causal-comparative research design (Creswell, 2009) was used in all three studies. Grade 5 and Grade 8 STAAR Mathematics and Science test data were analyzed for the 2011-2012 through the 2014-2015 school years. The dependent variables were the STAAR Mathematics and Science test scores for Grade 5 and Grade 8. The independent variables analyzed in these studies were student economic status, gender, and ethnicity/race. Findings. Regarding the first study, statistically significant differences were present in Grade 5 and Grade 8 STAAR Mathematics and Science test scores by student economic status for each year. Moderate effect sizes (Cohen's d) were present for each year of the study for the Grade 5 STAAR Mathematics and Science exams, Grade 8 Science exams, and the 2014-2015 Grade 8 STAAR Mathematics exam. However, a small effect size was present for the 2011-2012 through 2013-2014 Grade 8 STAAR Mathematics exam. Regarding the second and third study, statistically significant differences were revealed for Grade 5 and Grade 8 STAAR Mathematics and Science test scores based on gender, with trivial effect sizes. Furthermore, statistically significant differences were present in these test scores by ethnicity/race, with moderate effects for each year of the study. With regard to

  14. High & mighty: Implicit associations between space and social status

    Directory of Open Access Journals (Sweden)

    Stephanie eGagnon

    2011-10-01

    Full Text Available Figurative language, the built environment, and our perceptuo-motor experiences frequently associate social status with physical space. Linguistic references such as high status or climbing the corporate ladder, and built places such as the U.S. Capitol building link social and physical hierarchies. In three experiments we examine the source and extent of these associations by testing whether people implicitly associate abstract social status indicators with concrete representations of spatial topography (level versus mountainous land and relatively abstract representations of cardinal direction (south and north. Experiment 1 demonstrates speeded performance during an Implicit Association Test (IAT; Greenwald et al., 1998 when average social status is paired with level topography and high status with mountainous topography. Experiments 2 and 3 demonstrate a similar effect but with relatively abstract representations of cardinal direction (south and north, with speeded performance when average and powerful social status are paired with south and north coordinate space, respectively. Abstract concepts of social status are perceived and understood in an inherently spatial world, resulting in powerful associations between abstract social concepts and concrete and abstract notions of physical axes. These associations may prove influential in guiding daily judgments and actions.

  15. Effort, symptom validity testing, performance validity testing and traumatic brain injury.

    Science.gov (United States)

    Bigler, Erin D

    2014-01-01

    To understand the neurocognitive effects of brain injury, valid neuropsychological test findings are paramount. This review examines the research on what has been referred to a symptom validity testing (SVT). Above a designated cut-score signifies a 'passing' SVT performance which is likely the best indicator of valid neuropsychological test findings. Likewise, substantially below cut-point performance that nears chance or is at chance signifies invalid test performance. Significantly below chance is the sine qua non neuropsychological indicator for malingering. However, the interpretative problems with SVT performance below the cut-point yet far above chance are substantial, as pointed out in this review. This intermediate, border-zone performance on SVT measures is where substantial interpretative challenges exist. Case studies are used to highlight the many areas where additional research is needed. Historical perspectives are reviewed along with the neurobiology of effort. Reasons why performance validity testing (PVT) may be better than the SVT term are reviewed. Advances in neuroimaging techniques may be key in better understanding the meaning of border zone SVT failure. The review demonstrates the problems with rigidity in interpretation with established cut-scores. A better understanding of how certain types of neurological, neuropsychiatric and/or even test conditions may affect SVT performance is needed.

  16. Low vitamin D status is associated with reduced muscle mass and impaired physical performance in frail elderly people.

    Science.gov (United States)

    Tieland, M; Brouwer-Brolsma, E M; Nienaber-Rousseau, C; van Loon, L J C; De Groot, L C P G M

    2013-10-01

    Serum 25-hydroxyvitamin D (25(OH)D) status has been associated with muscle mass, strength and physical performance in healthy elderly people. Yet, in pre-frail and frail elderly people this association has not been studied. The objective of this study was to explore the association between vitamin D intake and serum 25(OH)D status with muscle mass, strength and physical performance in a pre-frail and frail elderly population. This cross-sectional study included 127 pre-frail and frail elderly people in The Netherlands. Whole body and appendicular lean mass (ALM) (dual energy X-ray absorptiometry), leg strength (one repetition maximum), handgrip strength and physical performance (short physical performance battery) were measured, and blood samples were collected for the assessment of serum 25(OH)D status (liquid chromatography-tandem mass spectrometry). In addition, habitual dietary intake (3-day food records) and physical activity data (accelerometers) were collected. In total, 53% of the participants had a serum 25(OH)D level below 50  nmol/l. After adjustment for confounding factors, 25(OH)D status was associated with ALM (β=0.012, P=0.05) and with physical performance (β=0.020, PVitamin D intake was associated with physical performance (β=0.18, P0.05). In this frail elderly population, 25(OH)D status is low and suggests a modest association with reduced ALM and impaired physical performance. In addition, vitamin D intake tended to be associated with impaired physical performance. Our findings highlight the need for well-designed intervention trials to assess the impact of vitamin D supplementation on 25(OH)D status, muscle mass and physical performance in pre-frail and frail elderly people.

  17. Nutritional status and cognitive performance of mother-child pairs in Sidama, Southern Ethiopia.

    Science.gov (United States)

    Bogale, Alemtsehay; Stoecker, Barbara J; Kennedy, Tay; Hubbs-Tait, Laura; Thomas, David; Abebe, Yewelsew; Hambidge, K Michael

    2013-04-01

    The purpose of this study was to assess the nutritional status and cognitive performance of women and their 5-year-old children using a cross-sectional design. Cognitive performance of mothers and children was assessed with Raven's Colored Progressive Matrices (CPM) and Kaufman Assessment Battery for Children-II (KABC-II). Demographic characteristics, food consumption patterns and anthropometry were also measured. Four rural districts in Sidama, southern Ethiopia served as the setting for this study. Subjects were one hundred women and their 5-year-old children. Mean ± standard deviation age of the mothers was 29 ± 6 years and family size was 7.0 ± 2.6. Maternal body mass index (BMI) ranged from 15.3 to 29.0 with 14% of the mothers having BMI children revealed 29% to be stunted (height-for-age z-score education significantly contributed to prediction of both mothers' and children's cognitive test scores. There were significant differences in mean cognitive test scores between stunted and non-stunted, and between underweight and normal-weight children. Height-for-age z-scores were correlated with scores for short-term memory (r = 0.42, P children with growth deficits suggesting that efficient and cost effective methods to alleviate malnutrition and food insecurity would impact not only child health but also cognitive function. © 2011 Blackwell Publishing Ltd.

  18. Spent fuel metal storage cask performance testing and future spent fuel concrete module performance testing

    International Nuclear Information System (INIS)

    McKinnon, M.A.; Creer, J.M.

    1988-10-01

    REA-2023 Gesellshaft fur Nuklear Service (GNS) CASTOR-V/21, Transnuclear TN-24P, and Westinghouse MC-10 metal storage casks, have been performance tested under the guidance of the Pacific Northwest Laboratory to determine their thermal and shielding performance. The REA-2023 cask was tested under Department of Energy (DOE) sponsorship at General Electric's facilities in Morris, Illinois, using BWR spent fuel from the Cooper Reactor. The other three casks were tested under a cooperative agreement between Virginia Power Company and DOE at the Idaho National Engineering Laboratory (INEL) by EGandG Idaho, Inc., using intact spent PWR fuel from the Surry reactors. The Electric Power Research Institute (EPRI) made contributions to both programs. A summary of the various cask designs and the results of the performance tests is presented. The cask designs include: solid and liquid neutron shields; lead, steel, and nodular cast iron gamma shields; stainless steel, aluminum, and copper baskets; and borated materials for criticality control. 4 refs., 8 figs., 6 tabs

  19. Human immunodeficiency virus testing behaviors among US adults: the roles of individual factors, legislative status, and public health resources.

    Science.gov (United States)

    Du, Ping; Camacho, Fabian; Zurlo, John; Lengerich, Eugene J

    2011-09-01

    The Centers for Disease Control and Prevention recommended an "opt-out" human immunodeficiency virus (HIV) testing strategy in 2006 for all persons aged 13 to 64 years at healthcare settings. We conducted this study to identify individual, health, and policy factors that may be associated with HIV testing in US adults. The 2008 Behavioral Risk Factors Surveillance System data were utilized. Individuals' residency states were classified into 4 categories based on the legislation status to HIV testing laws in 2007 and HIV/acquired immune deficiency syndrome morbidity. A multivariate logistic regression adjusting for survey designs was performed to examine factors associated with HIV testing. A total of 281,826 adults aged 18 to 64 years answered HIV testing questions in 2008. The proportions of US adults who had ever been tested for HIV increased from 35.9% in 2006 to 39.9% in 2008. HIV testing varied across the individual's characteristics including sociodemographics, access to regular health care, and risk for HIV infection. Compared with residents of "high morbidity-opt out" states, those living in "high morbidity-opt in" states with legislative restrictions for HIV testing had a slightly lower odds of being tested for HIV (adjusted odds ratio = 0.96; 95% confidence interval = 0.92, 1.01). Adults living in "low morbidity" states were significantly less likely to be tested for HIV, regardless of legislative status. To implement routine HIV testing in the general population, the role of public health resources should be emphasized and legislative barriers should be further reduced. Strategies need to be developed to reach people who do not have regular access to health care.

  20. Behavior, Expectations and Status

    Science.gov (United States)

    Webster, Jr, Murray; Rashotte, Lisa Slattery

    2010-01-01

    We predict effects of behavior patterns and status on performance expectations and group inequality using an integrated theory developed by Fisek, Berger and Norman (1991). We next test those predictions using new experimental techniques we developed to control behavior patterns as independent variables. In a 10-condition experiment, predictions…

  1. Relationship between the degree of insulin resistance during late gestation and postpartum performance in dairy cows and factors that affect growth and metabolic status of their calves.

    Science.gov (United States)

    Kawashima, Chiho; Munakata, Megumi; Shimizu, Takashi; Miyamoto, Akio; Kida, Katsuya; Matsui, Motozumi

    2016-06-01

    This study aimed to investigate the effects of insulin resistance (IR) during the close-up dry period on the metabolic status and performance of dairy cows as well as to determine the effects on body weight (BW) and metabolic status of their calves. An insulin tolerance test (ITT) was conducted by administering 0.05 IU/kg BW of insulin to 34 multiparous Holstein cows at 3 weeks prepartum. Blood samples were collected at 0, 30, 45 and 60 min after insulin injection, and cows were divided into two groups based on the time required for glucose to reach the minimum levels [non-IR (NIR), 45 min (n=28); and IR, 60 min (n=6)]. Blood or milk sampling and body condition score (BCS) estimation were performed twice weekly during the experimental period. Blood samples from calves were collected immediately after birth. Cows with IR showed lower BCS (Pinsulin-like growth factor-I concentration (Pinsulin concentration (Pdairy cows is related to postpartum metabolic status and performance along with growth and metabolic status of their calves.

  2. The effects of fatty fish intake on adolescents' nutritional status and associations with attention performance: results from the FINS-TEENS randomized controlled trial.

    Science.gov (United States)

    Handeland, Katina; Skotheim, Siv; Baste, Valborg; Graff, Ingvild E; Frøyland, Livar; Lie, Øyvind; Kjellevold, Marian; Markhus, Maria W; Stormark, Kjell M; Øyen, Jannike; Dahl, Lisbeth

    2018-02-23

    Adolescence involves changes in dietary habits that may induce imbalances in the intake of different nutrients. Fish is an important dietary source of omega-3 (n-3) long-chain polyunsaturated fatty acids (LCPUFAs), vitamin D, several minerals and high-quality protein. By using secondary outcomes and exploratory analyses, the aims of this paper were to evaluate if nutritional biomarkers (red blood cell fatty acids, serum (s)-25(OH)D, s-ferritin and urinary iodine concentration (UIC)) were altered during a dietary intervention, and if they mediated previously reported changes in attention performance. In addition, to examine the status of the biomarkers and explore associations between dietary pattern, biomarkers and attention performance cross-sectionally at baseline. The Fish Intervention Studies-TEENS (FINS-TEENS) was a three-armed intervention trial, including adolescents from eight secondary schools (n = 415; age: 14-15y) in Bergen, Norway. Participants were individually randomized to receive either fish meals, meat meals or n-3 LCPUFA supplements, three times a week for a total of 12 weeks. Blood and urine samples were collected pre and post intervention and attention performance was assessed with the d2 test of attention. Analyses of covariance (ANCOVA) assessed differences between groups in changes of biomarkers and linear mixed models were applied in analyses of attention performance and biomarkers. The trial is registered in ClinicalTrials.gov (NCT02350322). At baseline, the mean omega-3 index was 5.8 ± 1.3% and deficient status were identified for s-25(OH)D (54%), s-ferritin (10%) and UIC (40%). The intervention resulted in an increase in DHA and the omega-3 index which was larger in the supplement group compared to the fish and meat group (P < 0.01), and in the fish group compared to the meat group (P < 0.01). No differences between the groups were observed for changes in 25(OH)D, s-ferritin or UIC. None of the biomarkers mediated

  3. Taking the reins: the effects of new leader status and leadership style on team performance.

    Science.gov (United States)

    Sauer, Stephen J

    2011-05-01

    New leaders face a challenging task when they take charge of their teams. They have to determine how best to guide the work process, and they must understand how their behaviors will affect the members of their team. This research examines how a newly assigned team leader's status moderates subordinates' reactions to different leadership styles to affect assessments of the leader's self-confidence and effectiveness, and how this impacts team performance. Across 2 experimental studies, results demonstrate that low-status leaders are rated as more effective when they use a directive style, whereas high-status leaders are viewed as more effective when they use a participative style, and this relationship is mediated by perceptions of self-confidence. In addition, teams whose leaders are viewed more favorably perform better on a complex group task. These findings imply that low-status individuals are able to enhance their level of personal power by drawing on whatever positional power they hold, whereas high-status individuals are better off relying solely on their personal power to influence others. This research also provides a clear demonstration that assessments of new leaders' behaviors are subject to an appraisal that is clouded by observers' status perceptions and attributions.

  4. Engineered Barrier Test Facility status report, 1984

    International Nuclear Information System (INIS)

    Phillips, S.J.; Adams, M.R.; Gilbert, T.W.; Meinhardt, C.C.; Mitchell, R.M.; Waugh, W.J.

    1985-02-01

    This report provides a general summary of activities completed to date at the Hanford Engineered Barrier Test Facility. This facility is used to test and compare construction practices and performance of alternative designs of engineered barrier cover systems. These cover systems are being evaluated for potential use for isolation and confinement of buried waste disposal structures

  5. The Memory Alteration Test Discriminates between Cognitively Healthy Status, Mild Cognitive Impairment and Alzheimer's Disease

    Science.gov (United States)

    Custodio, Nilton; Lira, David; Herrera-Perez, Eder; Nuñez del Prado, Liza; Parodi, José; Guevara-Silva, Erik; Castro-Suarez, Sheila; Montesinos, Rosa; Cortijo, Patricia

    2014-01-01

    Background/Aims Dementia is a worldwide public health problem and there are several diagnostic tools for its assessment. The aim of this study was to evaluate the performance of the Memory Alteration Test (M@T) to discriminate between patients with early Alzheimer's disease (AD), patients with amnestic mild cognitive impairment (a-MCI), and subjects with a cognitively healthy status (CHS). Methods The discriminative validity was assessed in a sample of 90 patients with AD, 45 patients with a-MCI, and 180 subjects with CHS. Clinical, functional, and cognitive studies were independently performed in a blinded fashion and the gold standard diagnosis was established by consensus on the basis of these results. The test performance was assessed by means of a receiver operating characteristic curve analysis as area under the curve (AUC). Results M@T mean scores were 17.7 (SD = 5.7) in AD, 30.8 (SD = 2.3) in a-MCI, and 44.5 (SD = 3.1) in CHS. A cutoff score of 37 points had a sensitivity of 98.3% and a specificity of 97.8% to differentiate a-MCI from CHS (AUC = 0.999). A cutoff score of 27 points had a sensitivity of 100% and a specificity of 98.9% to differentiate mild AD from a-MCI and from CHS (AUC = 1.000). Conclusions The M@T had a high performance in the discrimination between early AD, a-MCI and CHS. PMID:25298775

  6. 10 CFR 26.168 - Blind performance testing.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Blind performance testing. 26.168 Section 26.168 Energy... and Human Services § 26.168 Blind performance testing. (a) Each licensee and other entity shall submit blind performance test samples to the HHS-certified laboratory. (1) During the initial 90-day period of...

  7. HIV Infection Status as a Predictor of Hepatitis C Virus RNA Testing in Primary Care

    Science.gov (United States)

    Yartel, Anthony K.; Morgan, Rebecca L.; Rein, David B.; Brown, Kimberly Ann; Kil, Natalie B.; Massoud, Omar I.; Fallon, Michael B.; Smith, Bryce D.

    2015-01-01

    Introduction Receipt of hepatitis C virus (HCV) RNA testing following a positive HCV antibody (anti-HCV+) test result to establish current infection is a quality indicator for HCV-related care. This study examines HIV infection status as a predictor of HCV RNA test receipt after an anti-HCV+ result in the primary care setting. Methods Electronic medical records of anti-HCV+ patients from a multisite retrospective study of patients aged ≥18 years who utilized one or more primary care outpatient services during 2005–2010 were analyzed in 2014. A multivariable logistic regression model examined the independent relationships between patient characteristics and receipt of HCV RNA testing. Results Among 1,115 anti-HCV+ patients, 133 (11.9%) were also HIV-positive. Of these, 77.4% (n=103) underwent HCV RNA testing to determine current infection status. By contrast, 66.7% (n=654/980) of anti-HCV+ patients who were HIV-negative received HCV RNA testing. Following multivariable adjustment, the odds of receiving HCV RNA testing were higher among anti-HCV+ patients who were also HIV-positive (AOR=1.9, 95% CI=1.2, 3.0), compared with their HIV-negative counterparts. Elevated alanine aminotransferase level was also associated with receipt of HCV RNA testing (AOR=1.9, 95% CI=1.4, 2.4). Black race was associated with decreased odds of receiving HCV RNA testing (AOR=0.7, 95% CI=0.5, 1.0). Conclusions HIV infection status is independently associated with the likelihood of receiving HCV RNA testing following an anti-HCV+ result. One quarter of anti-HCV+ patients who were also HIV-positive and one third of their HIV-negative counterparts, respectively, did not receive testing to establish active HCV infection, which is imperative for appropriate care and treatment. PMID:25896194

  8. Present status and future perspective of research and test reactors in JAERI

    International Nuclear Information System (INIS)

    Baba, Osamu; Kaieda, Keisuke

    1999-01-01

    Since 1957, Japan Atomic Energy Research Institute (JAERI) has constructed several research and test reactors to fulfil a major role in the study of nuclear energy and fundamental research. At present, four reactors, the Japan Research Reactor No. 3 and No. 4 (JRR-3M and JRR-4 respectively), the Japan Materials Testing Reactor (JMTR) and the Nuclear Safety Research Reactor (NSRR), are in operation, and a new High Temperature Engineering Test Reactor (HTTR) has reached first criticality and is waiting for the power-up test. This paper introduce these reactors and describe their present operational status. The recent tendency of utilization and future perspectives are also reported. (author)

  9. Present status and future perspective of research and test reactors in JAERI

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Osamu [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Kaieda, Keisuke

    1999-08-01

    Since 1957, Japan Atomic Energy Research Institute (JAERI) has constructed several research and test reactors to fulfil a major role in the study of nuclear energy and fundamental research. At present, four reactors, the Japan Research Reactor No. 3 and No. 4 (JRR-3M and JRR-4 respectively), the Japan Materials Testing Reactor (JMTR) and the Nuclear Safety Research Reactor (NSRR), are in operation, and a new High Temperature Engineering Test Reactor (HTTR) has reached first criticality and is waiting for the power-up test. This paper introduce these reactors and describe their present operational status. The recent tendency of utilization and future perspectives are also reported. (author)

  10. Field performance assessment of synthetic liners for uranium tailings ponds: a status report

    International Nuclear Information System (INIS)

    Mitchell, D.H.; Spanner, G.E.

    1984-03-01

    The objective of this study is to provide a database to support US Nuclear Regulatory Commission (NRC) licensing of uranium tailings leachate isolation impoundments. This objective is being accomplished by determining the effectiveness of design, installation, and quality assurance practices associated with uranium mill tailings impoundments with flexible membrane liners. The program includes testing of chemical resistance and physical performance of liners, leak detection systems, and seam inspection techniques. This report presents the status of the program through September 1983. The report addresses impoundment design, installation, and inspection techniques used by the uranium milling industry. To determine the relative successes of these techniques, information has been collected from consultants, mill operators, and the synthetic liner industry. Progress in experimental tasks on chemical resistance of liners, physical properties of liners, and nondestructive examination of seams is reported. 25 references, 9 figures, 13 tables

  11. Performance Testing of Cutting Fluids

    DEFF Research Database (Denmark)

    Belluco, Walter

    The importance of cutting fluid performance testing has increased with documentation requirements of new cutting fluid formulations based on more sustainable products, as well as cutting with minimum quantity of lubrication and dry cutting. Two sub-problems have to be solved: i) which machining...... tests feature repeatability, reproducibility and sensitivity to cutting fluids, and ii) to what extent results of one test ensure relevance to a wider set of machining situations. The present work is aimed at assessing the range of validity of the different testing methods, investigating correlation...... within the whole range of operations, materials, cutting fluids, operating conditions, etc. Cutting fluid performance was evaluated in turning, drilling, reaming and tapping, and with respect to tool life, cutting forces, chip formation and product quality (dimensional accuracy and surface integrity...

  12. Socioeconomic Status and Performance in the US Army and US Marine Corps

    National Research Council Canada - National Science Library

    Booth, Stefan

    1998-01-01

    The purpose or this study was to examine socioeconomic status (SES) of recruits in the Army and Marine Corps and to analyze the relationship between a recruit's SES background and his or her performance in the military over time...

  13. Factors Contributing to Single- and Dual-Task Timed "Up & Go" Test Performance in Middle-Aged and Older Adults Who Are Active and Dwell in the Community.

    Science.gov (United States)

    Chen, Hui-Ya; Tang, Pei-Fang

    2016-03-01

    Dual-task Timed "Up & Go" (TUG) tests are likely to have applications different from those of a single-task TUG test and may have different contributing factors. The purpose of this study was to compare factors contributing to performance on single- and dual-task TUG tests. This investigation was a cross-sectional study. Sixty-four adults who were more than 50 years of age and dwelled in the community were recruited. Interviews and physical examinations were performed to identify potential contributors to TUG test performance. The time to complete the single-task TUG test (TUGsingle) or the dual-task TUG test, which consisted of completing the TUG test while performing a serial subtraction task (TUGcognitive) or while carrying water (TUGmanual), was measured. Age, hip extensor strength, walking speed, general mental function, and Stroop scores for word and color were significantly associated with performance on all TUG tests. Hierarchical multiple regression models, without the input of walking speed, revealed different independent factors contributing to TUGsingle performance (Mini-Mental Status Examination score, β=-0.32), TUGmanual performance (age, β=0.35), and TUGcognitive performance (Stroop word score, β=-0.40; Mini-Mental Status Examination score, β=-0.31). At least 40% of the variance in the performance on the 3 TUG tests was not explained by common clinical measures, even when the factor of walking speed was considered. However, this study successfully identified some important factors contributing to performance on different TUG tests, and other studies have reported similar findings for single-task TUG test and dual-task gait performance. Although the TUGsingle and the TUGcognitive shared general mental function as a common factor, the TUGmanual was uniquely influenced by age and the TUGcognitive was uniquely influenced by focused attention. These results suggest that both common and unique factors contribute to performance on single- and dual

  14. Differences in eating behaviors and masticatory performances by gender and obesity status.

    Science.gov (United States)

    Park, Soojin; Shin, Weon-Sun

    2015-01-01

    This study aimed to determine whether there might be differences in masticatory performance and eating behaviors by gender and obesity status. Forty eight (24 males; 24 females) non-obese and pre-obese young adults were matched for age, gender, and dental health. Eating behaviors were assessed using the Three-Factor Eating Questionnaire (TFEQ), and chewing performance while eating 152g of boiled rice was measured using electromyography (EMG). Compared with non-obese participants, pre-obese participants had significantly higher levels of disinhibition according to the TFEQ (Pdifferent by gender but not by obesity status. Males had a greater bite size (Pobese) and chewing power (r=-0.581, Pobese and r=-0.446, Pobese) were negatively associated with disinhibition score. Results suggest that the effects of gender and, in part, obesity on eating responses may be explained as chewing performance. Therefore, gender-specific interventions and counseling aimed at slowing the rate of ingestion could be promising behavioral treatments for obese persons. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Hospital nurse job attitudes and performance: the impact of employment status.

    Science.gov (United States)

    Chu, Cheng-I; Hsu, Yao-Feng

    2011-03-01

    According to the 2007 Taiwan Labor Front Human Resources Report, as much as 47.6% of nurses at some public hospitals were contracted rather than full time. Furthermore, turnover rates for contract nurses were found to be as high as five to eight times of those for full-time nurses. Because high turnover rates are likely to induce negative impacts on the stability of care provided in the absence of staffing continuity, the association between nursing employment arrangement and nursing care quality is attracting greater attention. This study was designed to investigate the work status of contract versus full-time nurses at a public hospital in Taiwan and to examine the impact of such on work-related attitudes, organizational citizenship behavior, and job performance. Samples were recruited from a public hospital in Taiwan. In addition to self-rated items, researchers used supervisor-rated structured questionnaires for job performance to attenuate the possible effect of common method bias. The study investigated the impact of hospital nurse employment status on work-related attitudes, organizational citizenship behavior, and job performance using a regression model that included the critical work-related attitudes variables of job satisfaction and organizational commitment. Study findings included the following: (a) organizational commitment, job satisfaction, organizational citizenship behavior, and job performance correlate positively with one another. (b) No significant difference between contract and full-time nurses was found in terms of organizational commitment, job satisfaction, organizational citizenship behavior, and self-rated job performance. However, when rated by supervisors, reported job performance levels for full-time nurses were significantly higher than those of contract nurses. (c) Organizational citizenship behavior exhibited a mediating effect between job satisfaction, organizational commitment, and job performance. In this study, supervisors

  16. Waste Management at the Nevada Test Site Fiscal Year 2001 Current Status

    International Nuclear Information System (INIS)

    Becker, B.D.; Clayton, W.A.; Crowe, B.M.

    2002-01-01

    The performance objectives of the U. S. Department of Energy's National Nuclear Security Administration Nevada Operations Office (NNSA/NV) Low-level Radioactive Waste (LLW) disposal facilities located at the Nevada Test Site transcend those of any other radioactive waste disposal site in the United States. Situated at the southern end of the Great Basin, 244 meters (800 feet) above the water table, the Area 5 Radioactive Waste Management Site (RWMS) has utilized a combination of engineered shallow land disposal cells and deep augured shafts to dispose a variety of waste streams. These include high volume low-activity waste, classified radioactive material, and high-specific-activity special case waste. Fifteen miles north of Area 5 is the Area 3 RWMS. Here bulk LLW disposal takes place in subsidence craters formed from underground testing of nuclear weapons. Earliest records indicate that documented LLW disposal activities have occurred at the Area 5 and Area 3 RWMSs since 1961 and 1 968, respectively. However, these activities have only been managed under a formal program since 1978. This paper describes the technical attributes of the facilities, present and future capacities and capabilities, and provides a description of the process from waste approval to final disposition. The paper also summarizes the current status of the waste disposal operations

  17. Validity and Relative Ability of 4 Balance Tests to Identify Fall Status of Older Adults With Type 2 Diabetes.

    Science.gov (United States)

    Marques, Alda; Silva, Alexandre; Oliveira, Ana; Cruz, Joana; Machado, Ana; Jácome, Cristina

    The Berg Balance Scale (BBS), the Balance Evaluation Systems Test (BESTest), the Mini-BESTest, and the Brief-BESTest are useful tests to assess balance; however, their clinimetric properties have not been studied well in older adults with type 2 diabetes (T2D). This study compared the validity and relative ability of the BBS, BESTest, Mini-BESTest, and Brief-BESTest to identify fall status in older adults with T2D. This study involved a cross-sectional design. Sixty-six older adults with T2D (75 ± 7.6 years) were included and asked to report the number of falls during the previous 12 months and to complete the Activities-specific Balance Confidence scale. The BBS and the BESTest were administered, and the Mini-BESTest and Brief-BESTest scores were computed based on the BESTest performance. Receiver operating characteristics were used to assess the ability of each balance test to differentiate between participants with and without a history of falls. The 4 balance tests were able to identify fall status (areas under the curve = 0.74-0.76), with similar sensitivity (60%-67%) and specificity (71%-76%). The 4 balance tests were able to differentiate between older adults with T2D with and without a history of falls. As the BBS and the BESTest require longer application time, the Brief-BESTest may be an appropriate choice to use in clinical practice to detect fall risk.

  18. Driving with Mild Cognitive Impairment or Dementia: Cognitive Test Performance and Proxy Report of Daily Life Function in Older Women.

    Science.gov (United States)

    Vaughan, Leslie; Hogan, Patricia E; Rapp, Stephen R; Dugan, Elizabeth; Marottoli, Richard A; Snively, Beverly M; Shumaker, Sally A; Sink, Kaycee M

    2015-09-01

    To investigate associations between proxy report of cognitive and functional limitations and cognitive performance and current or former driving status in older women with mild cognitive impairment (MCI) and all-cause dementia. Cross-sectional data analysis of retrospectively identified older women with adjudicated MCI and all-cause dementia in the Women's Health Initiative Memory Study-Epidemiology of Cognitive Health Outcomes (WHIMS-ECHO). Academic medical center. Women (mean age ± standard deviation 83.7 ± 3.5) adjudicated with MCI or dementia during Year 1, 2, 3, or 4 of the WHIMS-ECHO follow-up period (N = 385). The telephone-administered cognitive battery included tests of attention, verbal learning and memory, verbal fluency, executive function, working memory, and global cognitive function plus self-report measures of depressive symptomatology. The Dementia Questionnaire (DQ) was administered to a knowledgeable proxy (family member, friend). Sixty percent of women with MCI and 40% of those with dementia are current drivers. Proxy reports of functional limitations in instrumental activities of daily living (IADLs) are associated with current driving status in women with MCI, whereas performance-based cognitive tests are not. In women with dementia, proxy reports of functional limitations in IADLs and performance-based cognitive tests are associated with current driving status, as expected. These findings have clinical implications for the importance of evaluating driving concurrently with other instrumental functional abilities in MCI and dementia. Additional work is needed to determine whether proxy report of cognitive and functional impairments should help guide referrals for driving assessment and rehabilitation or counseling for driving transition. © 2015, Copyright the Authors Journal compilation © 2015, The American Geriatrics Society.

  19. The Radiosurgical Treatment of Arteriovenous Malformations: Obliteration, Morbidities, and Performance Status

    International Nuclear Information System (INIS)

    Sun, Daniel Q.; Carson, Kathryn A.; Raza, Shaan M.; Batra, Sachin; Kleinberg, Lawrence R.; Lim, Michael; Huang, Judy; Rigamonti, Daniele

    2011-01-01

    Objective: This study examined the single-center treatment outcomes of arteriovenous malformations (AVMs) of the brain using stereotactic radiosurgery, with regard to obliteration, predictive factors, morbidities, and patient performance status. Patients and Methods: 127 patients were treated between 1990 and 2008 by use of linear accelerator or Gamma Knife. Their median age was 37 years, the median AVM volume was 7.3 cc (range, 0.014-113.13 cc), and the median follow-up duration was 42 months (range, 6-209 months). Forty-two percent of patients presented with intracranial hemorrhage, 31% received embolization, and 8% underwent prior resection. Thirty-one percent of patients received more than one round of radiosurgery. Results: 64% of patients had complete obliteration confirmed by magnetic resonance imaging or angiography. Positive predictors of obliteration included pretreatment hemorrhage (p = 0.042), smaller AVM volume (odds ratio = 1.25; 95% CI, 1.03-1.52), and larger marginal dose (odds ratio = 0.292; 95% CI, 0.100-0.820), whereas embolization (p < 0.001) was a negative predictor . The annual risk of hemorrhage after radiosurgery was 2.2%, and the risk of death as a result of hemorrhage was 0.6-1.3%. Eleven percent of patients reported new or worsened neurologic symptoms. Radiosurgery was effective in treating AVM-related headaches (p < 0.001) but did not improve the performance status of patients. Conclusions: Stereotactic radiosurgery is an effective tool in the treatment of AVMs and amelioration of AVM-related headaches, but it did not affect the patients' performance status. Factors affecting obliteration include prior hemorrhage, marginal dose, prior embolization, and AVM volume. Risk of hemorrhage persists in the latency period after radiosurgery, and it remains finite even after complete obliteration.

  20. Concepts for Multi-Speed Rotorcraft Drive System - Status of Design and Testing at NASA GRC

    Science.gov (United States)

    Stevens, Mark A.; Lewicki, David G.; Handschuh, Robert F.

    2015-01-01

    In several studies and on-going developments for advanced rotorcraft, the need for variable/multi-speed capable rotors has been raised. Speed changes of up to 50 percent have been proposed for future rotorcraft to improve vehicle performance. A rotor speed change during operation not only requires a rotor that can perform effectively over the operating speed/load range, but also requires a propulsion system possessing these same capabilities. A study was completed investigating possible drive system arrangements that can accommodate up to a 50 percent speed change. Key drivers were identified from which simplicity and weight were judged as central. This paper presents the current status of two gear train concepts coupled with the first of two clutch types developed and tested thus far with focus on design lessons learned and areas requiring development. Also, a third concept is presented, a dual input planetary differential as leveraged from a simple planetary with fixed carrier.

  1. ACCESS: Thermal Mechanical Design, Performance, and Status

    Science.gov (United States)

    Kaiser, Mary Elizabeth; Morris, M. J.; McCandliss, S. R.; Rauscher, B. J.; Kimble, R. A.; Kruk, J. W.; Wright, E. L.; Bohlin, R.; Kurucz, R. L.; Riess, A. G.; Pelton, R.; Deustua, S. E.; Dixon, W. V.; Sahnow, D. J.; Benford, D. J.; Gardner, J. P.; Feldman, P. D.; Moos, H. W.; Lampton, M.; Perlmutter, S.; Woodgate, B. E.

    2014-01-01

    Systematic errors associated with astrophysical data used to probe fundamental astrophysical questions, such as SNeIa observations used to constrain dark energy theories, are now rivaling and exceeding the statistical errors associated with these measurements. ACCESS: Absolute Color Calibration Experiment for Standard Stars is a series of rocket-borne sub-orbital missions and ground-based experiments designed to enable improvements in the precision of the astrophysical flux scale through the transfer of absolute laboratory detector standards from the National Institute of Standards and Technology (NIST) to a network of stellar standards with a calibration accuracy of 1% and a spectral resolving power of 500 across the 0.35 - 1.7μm bandpass. Achieving this level of accuracy requires characterization and stability of the instrument and detector including a thermal background that contributes less than 1% to the flux per resolution element in the NIR. We will present the instrument and calibration status with a focus on the thermal mechanical design and associated performance data. The detector control and performance will be presented in a companion poster (Morris, et al). NASA APRA sounding rocket grant NNX08AI65G supports this work.

  2. Physical status of the 10 MW test module

    International Nuclear Information System (INIS)

    Luo Jingyu

    1991-01-01

    Like most graphite moderated HTR systems, the 10 MW Test-Module reactor is undermoderated. This means if the water ingress is into the pebble bed that this system will gain reactivity as moderator is added to the core. The reactivity increase caused by water ingress strongly depends on the geometry of the core, the temperature, the burnup status and especially the moderator to fuel ratio (the metal content per fuel element). For the equilibrium core 5 gram of heavy metal per fuel element is chosen in order to limit the effect of water ingress. Another important effect of water ingress is to reduce the worth of control rods which are usually located in the reflector. The distance between core and control rods in the reflector are carefully calculated. In the 10 MW Test-Module reactor the core shutdown capability of 12 control rods are selected such that any accident reactivity can be counterbalanced and only half of the rods have to be available to render the reactor down from normal operation to the cold, permanent subcritical condition. (author). 5 figs, 3 tabs

  3. Use of the Cognitive Performance Test for Identifying Deficits in Hospitalized Older Adults

    Directory of Open Access Journals (Sweden)

    Alison Douglas

    2012-01-01

    Full Text Available Objectives. The Cognitive Performance Test (CPT is a functional assessment for persons with dementia. The study purpose was to evaluate the reliability, discriminant, and concurrent validity of the CPT. Method. The CPT was tested against other measures of cognition (Standardized Mini Mental Status Exam (SMMSE and Assessment of Motor and Process Skills-Process scale (AMPS-Process. Participants were persons 65 years and older admitted to a geriatric rehabilitation unit (n=47. Results. The CPT correlated moderately with measures of cognition (SMMSE r=0.47, AMPS-Process r=0.53, P<0.01, and ADL burden of care (FIM r=0.32, P<0.05. Scores were not affected by age, sex, years of education, motor skills, or comorbidities. The CPT differentiated between impaired and unimpaired individuals differently from other measures. Conclusion. While CPT appears related to other measures of cognition, test interpretation requires noting the variability between CPT scores and those measures.

  4. Advanced fuel technology and performance: Current status and trends

    International Nuclear Information System (INIS)

    1990-11-01

    During the last years the Nuclear Fuel Cycle and Waste Management Division of the IAEA has been giving great attention to the collection, analysis and exchange of information in the field of reactor fuel technology. Most of these activities are being conducted in the framework of the International Working Group on Water Reactor Fuel Performance and Technology (IWGFPT). The purpose of this Advisory Group Meeting on Advanced Fuel Technology and Performance was to update and to continue the previous work, and to review the experience of advanced fuel technology, its performance with regard to all types of reactors and to outline the future trends on the basis of national experience and discussions during the meeting. As a result of the meeting a Summary Report was prepared which reflected the status of the advanced nuclear fuel technology up to 1990. The 10 papers presented by participants of this meeting are also published here. A separate abstract was prepared for each of these papers. Refs, figs and tabs

  5. HIV Testing and Awareness of Partner's HIV Status Among Chinese Men Who Have Sex with Men in Main Partnerships.

    Science.gov (United States)

    Wei, Chongyi; Yan, Hongjing; Raymond, H Fisher; Shi, Ling-En; Li, Jianjun; Yang, Haitao; McFarland, Willi

    2016-04-01

    Many men who have sex with men (MSM) do not use condoms with their main partners, especially if both parties are of the same HIV status. However, significant proportions of MSM have never tested or recently tested and are unaware of their main partners' HIV status. A cross-sectional survey was conducted among 524 MSM in Jiangsu, China in 2013-2014. Time-location sampling and online convenience sampling were used to recruit participants. We compared awareness of HIV status and recent HIV testing between participants who had main partners versus those who did not, and identified factors associated with recent HIV testing among men in main partnerships. Participants in main partnerships were significantly more likely to report recent HIV testing and being HIV-negative instead of HIV-unknown compared to participants in casual partnerships only. Overall, 74.5 % of participants were aware of their main partners' HIV status. Among participants in main partnerships, those who had 2-5 male anal sex partners in the past 6 months and those who reported that their partners were HIV-negative had 2.36 (95 % CI 1.12, 4.97) and 4.20 (95 % CI 2.03, 8.70) fold greater odds of being tested in the past year compared to those who had main partners only and those whose partners were HIV-positive/unknown, respectively. Chinese MSM in main partnerships might be practicing serosorting and may be at lower risk for HIV infection due to increased awareness of main partners' HIV status and higher uptake of recent testing.

  6. Nuclear material control and accountancy planning and performance testing

    International Nuclear Information System (INIS)

    Mike Enhinger; Dennis Wilkey; Rod Martin; Ken Byers; Brian Smith

    1999-01-01

    An overview of performance testing as used at U.S. Department of Energy facilities is provided. Performance tests are performed on specific aspects of the regulations or site policy. The key issues in establishing a performance testing program are: identifying what needs to be tested; determining how to test; establishing criteria to evaluate test results. The program elements of performance testing program consist of: planning; coordination; conduct; evaluation. A performance test may be conducted of personnel or equipment. The DOE orders for nuclear material control and accountancy are divided into three functional areas: program administration, material accounting, and material control. Examples performance tests may be conducted on program administration, accounting, measurement and measurement control, inventory, and containment [ru

  7. Use of computerized tests to evaluate psychomotor performance in children with specific learning disabilities in comparison to normal children

    Directory of Open Access Journals (Sweden)

    Santosh Taur

    2014-01-01

    Full Text Available Background & objectives: Children with specific learning disabilities (SpLD have an unexplained difficulty in acquiring basic academic skills resulting in a significant discrepancy between their academic potential and achievements. This study was undertaken to compare the performance on a battery of six psychomotor tests of children with SpLD and those without any learning disabilities (controls using computerized tests. Methods: In this study, 25 children with SpLD and 25 controls (matched for age, socio-economic status and medium of instruction were given three training sessions over one week. Then children were asked to perform on the six computerized psychomotor tests. Results were compared between the two groups. Results: Children with SpLD fared significantly worse on finger tapping test, choice reaction test, digit picture substitution test and card sorting test compared to the controls ( p <0.05. Interpretation & conclusions: Children with SpLD have impairment of psychomotor skills like attention, sensory-motor coordination and executive functioning. Further research is needed to evaluate if the remedial education plan results in improvement in psychomotor performance of children with SpLD on these selected tests.

  8. Status of the realization of the neutral beam test facility

    International Nuclear Information System (INIS)

    Toigo, Vanni

    2015-01-01

    The ITER Neutral Beam Injectors (NBI) are required to deliver 16.5 MW of additional heating power to the plasma, accelerating negative ions up to -1 MV with a beam current of 40A lasting up to 1 hour. Since these outstanding requirements were never achieved all together so far, the realization of a Neutral Beam Test Facility (NBTF), called PRIMA, currently under construction in Padova, was launched with the aim to test the operation of the NB injector and to study the relevant physical and technological issues, in advance to the implementation in ITER. Two projects are under development: MITICA and SPIDER. MITICA is a full scale prototype of the ITER NB injector; the design is based on a similar scheme and layout, with the same power supply system and also the control and protection systems are being designed according to the ITER rules and constraints. The HV components are procured by JADA; the low voltage ones and the injector are procured by F4E. SPIDER project is an ion source with the same characteristics of the ITER one, specifically addressed to study the issues related to the RF operation; for this reason, the beam energy is limited to 100keV. It can generate both Hydrogen and Deuterium Ions; the design includes provisions to filter electrons and also to allow the use of cesium to attain the high values of current density required. SPIDER is procured by F4E and INDA. The construction of PRIMA buildings and auxiliaries, started in autumn 2008, was completed in summer 2015. SPIDER plant systems procurement is well advanced and some systems are under installation or site acceptance tests. In 2016 integrated commissioning and power supply integrated tests will be performed followed by the beginning of the first experimental phase. MITICA design was completed; many procurement contracts have been signed or will be launched in the next months. Installation activity will start in December 2015 with the installation of the first HV power supply components provided

  9. DECADE design and testing status

    International Nuclear Information System (INIS)

    Sincerny, P.; Childers, K.; Goyer, J.; Kortbawi, D.; Roth, I.; Stallings, C.; Dempsey, J.; Schlitt, L.

    1996-01-01

    DECADE is a very high power generator that will be built at Arnold Engineering Development Center in Tullahoma, Tennessee, by the Defense Special Weapons Agency. The full facility consists of 16 modules. Two full power modules (DM1 and DM2) have been built to verify the DECADE design at Physics International. Each module consists of a 570 kJ Marx generator that pulse charges a water transfer capacitor. The transfer capacitor discharges into a water output line through an array of 6 parallel triggered gas switches. The water output line then pulse charges the inductive store/opening switch pulse compression stage. When the opening switch opens, the inductive store discharges into an electron beam bremsstrahlung diode load. The initial testing of the DM1 module has been completed. The electrical design of the module will be presented, including circuit modeling results. The test data from a module will be compared to the modeling results. This test data, including reproducibility and timing accuracy, was used to predict the output from the full system of 16 modules and a subset of 4 unit modules (DECADE Quad). One option under consideration is to deploy a DECADE Quad at the testing center in Tennessee prior to the full 16 module system. The design sketch of the DECADE Quad and the predicted output based on the modeling and the demonstrated module performance is given. (author). 11 figs., 11 refs

  10. DECADE design and testing status

    Energy Technology Data Exchange (ETDEWEB)

    Sincerny, P; Childers, K; Goyer, J; Kortbawi, D; Roth, I; Stallings, C; Dempsey, J [Physics International Company, San Leandro, CA (United States); Schlitt, L [Leland Schlitt Consulting Services, Livermore, CA (United States)

    1997-12-31

    DECADE is a very high power generator that will be built at Arnold Engineering Development Center in Tullahoma, Tennessee, by the Defense Special Weapons Agency. The full facility consists of 16 modules. Two full power modules (DM1 and DM2) have been built to verify the DECADE design at Physics International. Each module consists of a 570 kJ Marx generator that pulse charges a water transfer capacitor. The transfer capacitor discharges into a water output line through an array of 6 parallel triggered gas switches. The water output line then pulse charges the inductive store/opening switch pulse compression stage. When the opening switch opens, the inductive store discharges into an electron beam bremsstrahlung diode load. The initial testing of the DM1 module has been completed. The electrical design of the module will be presented, including circuit modeling results. The test data from a module will be compared to the modeling results. This test data, including reproducibility and timing accuracy, was used to predict the output from the full system of 16 modules and a subset of 4 unit modules (DECADE Quad). One option under consideration is to deploy a DECADE Quad at the testing center in Tennessee prior to the full 16 module system. The design sketch of the DECADE Quad and the predicted output based on the modeling and the demonstrated module performance is given. (author). 11 figs., 11 refs.

  11. Prognostic factors in patients with malignant pleural effusion: Is it possible to predict mortality in patients with good performance status?

    Science.gov (United States)

    Abrao, Fernando Conrado; Peixoto, Renata D'Alpino; de Abreu, Igor Renato Louro Bruno; Janini, Maria Cláudia; Viana, Geisa Garcia; de Oliveira, Mariana Campello; Younes, Riad Naim

    2016-04-01

    The aim of this study was to identify predictors of mortality only in patients with malignant pleural effusion (MPE) showing good performance status which required pleural palliative procedures. All patients with MPE submitted to pleural palliative procedure were enrolled in a prospective study between 2013 and 2014. Patients with Eastern cooperative oncology group (ECOG) score zero, one, and two were considered with good performance status. The possible prognostic factors were tested for significance using the log-rank test (Kaplan-Meier method) and those with significance on univariate analysis were entered into a multivariable Cox model. A total of 64 patients were included in the analysis. Median follow-up time for surviving patients was 263 days. Median survival for the entire cohort was not reached yet. In the multivariate analysis, gastrointestinal primary site (P = 0.006), low albumin concentration in the pleural fluid (P = 0.017), and high serum NLR (P = 0.007) were associated with mortality. In our cohort of ECOG 0-2 patients with MPE submitted to pleural palliative procedures, gastrointestinal malignancy compared to other sites, low pleural fluid albumin and high NLR were significantly associated with mortality. The identification of these prognostic factors may assist the choice of the optimal palliative technique. J. Surg. Oncol. 2016;113:570-574. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  13. Effect of dietary antioxidants, training, and performance correlates on antioxidant status in competitive rowers.

    Science.gov (United States)

    Braakhuis, Andrea J; Hopkins, Will G; Lowe, Timothy E

    2013-09-01

    The beneficial effects of exercise and a healthy diet are well documented in the general population but poorly understood in elite athletes. Previous research in subelite athletes suggests that regular training and an antioxidant-rich diet enhance antioxidant defenses but not performance. To investigate whether habitual diet and/or exercise (training status or performance) affect antioxidant status in elite athletes. Antioxidant blood biomarkers were assessed before and after a 30-min ergometer time trial in 28 male and 34 female rowers. The antioxidant blood biomarkers included ascorbic acid, uric acid, total antioxidant capacity (TAC), erythrocyte- superoxide dismutase, glutathione peroxidase (GPx), and catalase. Rowers completed a 7-d food diary and an antioxidant-intake questionnaire. Effects of diet, training, and performance on resting biomarkers were assessed with Pearson correlations, and their effect on exercise-induced changes in blood biomarkers was assessed by a method of standardization. With the exception of GPx, there were small to moderate increases with exercise for all markers. Blood resting TAC had a small correlation with total antioxidant intake (correlation .29; 90% confidence limits, ±.27), and the exercise-induced change in TAC had a trivial to small association with dietary antioxidant intake from vitamin C (standardized effect .19; ±.22), vegetables (.20; ±.23), and vitamin A (.25; ±.27). Most other dietary intakes had trivial associations with antioxidant biomarkers. Years of training had a small inverse correlation with TAC (-.32; ±.19) and a small association with the exercise-induced change in TAC (.27; ±.24). Training status correlates more strongly with antioxidant status than diet does.

  14. A longitudinal study of childhood obesity, weight status change, and subsequent academic performance in Taiwanese children.

    Science.gov (United States)

    Chen, Li-Jung; Fox, Kenneth R; Ku, Po-Wen; Wang, Ching-Hui

    2012-09-01

    This study examined the association among childhood obesity, weight status change, and subsequent academic performance at 6-year follow-up. First-grade students from one elementary school district in Taichung City, Taiwan were followed for 6 years (N = 409). Academic performance was extracted from the school records at the end of each grade. Weight and height were measured at the beginning of each grade. A weight change variable was created based on each child's weight status difference at grades 1 and 6. A multivariate linear regression model for predicting academic performance at grade 6 was developed with adjustment for individual characteristics and family factors. A latent growth curve (LGC) showed the association between changes in body mass index (BMI) and in academic performance across a 6-year period. BMI in children increased significantly across 6 years. The rate of increase in BMI over 6 years was higher for children with higher baseline BMIs than it was for children with lower baseline BMIs. However, BMI changes were not significantly associated with changes of academic performance. There was no significant relationship between initial obesity or change in weight status and subsequent academic performance. It appears that either being or becoming overweight/obese did not impact academic achievement for these Taiwanese children. © 2012, American School Health Association.

  15. Effects of nutritional status on academic performance of Malaysian primary school children.

    Science.gov (United States)

    Zaini, M Z Anuar; Lim, C T; Low, W Y; Harun, F

    2005-01-01

    Numerous factors are known to affect the academic performance of students. These include prenatal conditions, birth conditions, postnatal events, nutritional, socio-economic factors and environmental factors. This paper examines the nutritional status and its relationship with academic performance of 9-10 years old primary school children recruited randomly in Selangor, Malaysia. A standard self-administered questionnaire was utilized to obtain pertinent information and a face-to-face interview was also conducted with the parents. Results of the academic performances were extracted from the students' report cards. The intellectual performance was assessed using Raven's Coloured Progressive Matrices. Physical examination was also conducted on these students by doctors. Overall 1,405 students and 1,317 parents responded to the survey. Of these 83.6% were Malays, 11.6% Indians, and 4.2% Chinese. The majority of them (82.9%) were from urban areas. The female: male ratio was 51:49; mean age was 9.71 years. The mean height and weight were 32.3 kg and 135.2 cm respectively. Their mean BMI was 17.42 kg/cm2, with 0.9% underweight, 76.3% normal BMI, 16.3% overweight, and 6.3% obese. Academic performance was significantly correlated with breast feeding, income and educational level of their parents, BMI, and whether they have been taking breakfast. There was a weak correlation between presence of anaemia and intellectual performance. Improving the socio-economic status of the parents will lend a helping hand in the academic performance of the students. Since breast feeding is associated with better academic and intellectual performance it must be emphasized, particularly to expectant mothers in the antenatal clinics.

  16. Performance analysis of spectrum sensing with multiple status changes in primary user traffic

    KAUST Repository

    Tang, Liang; Chen, Yunfei; Hines, Evor L.; Alouini, Mohamed-Slim

    2012-01-01

    In this letter, the impact of primary user traffic with multiple status changes on the spectrum sensing performance is analyzed. Closed-form expressions for the probabilities of false alarm and detection are derived. Numerical results show

  17. Status of the flora and fauna on the Nevada Test Site, 1992. Results of continuing basic environmental monitoring, January through December 1992

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, R.B. [comp.

    1994-03-01

    This report documents changes in the populations of plants and animals on the Nevada Test Site (NTS) for calendar year 1992. It is part of a Department of Energy (DOE) program (Basic Environmental Compliance and Monitoring Program -- BECAMP) that also includes monitoring DOE compliance with the Endangered Species Act, the Historic Preservation Act, and the American Indian Freedom of Religion Act. Ecological studies were to comply with the National Environmental Policy Act and DOE Order 5400.1, ``General Environmental Protection Program.`` These studies focused on the following: status of ephemeral plants on the Nevada Test Site, 1992; status of reptile and amphibian populations on the Nevada Test Site, 1992; trends in small mammal populations on the Nevada Test Site, 1992; status of large mammals and birds at Nevada Test Site, 1992; and status of perennial plants on the Nevada Test Site, 1992.

  18. Vitrification Facility integrated system performance testing report

    International Nuclear Information System (INIS)

    Elliott, D.

    1997-01-01

    This report provides a summary of component and system performance testing associated with the Vitrification Facility (VF) following construction turnover. The VF at the West Valley Demonstration Project (WVDP) was designed to convert stored radioactive waste into a stable glass form for eventual disposal in a federal repository. Following an initial Functional and Checkout Testing of Systems (FACTS) Program and subsequent conversion of test stand equipment into the final VF, a testing program was executed to demonstrate successful performance of the components, subsystems, and systems that make up the vitrification process. Systems were started up and brought on line as construction was completed, until integrated system operation could be demonstrated to produce borosilicate glass using nonradioactive waste simulant. Integrated system testing and operation culminated with a successful Operational Readiness Review (ORR) and Department of Energy (DOE) approval to initiate vitrification of high-level waste (HLW) on June 19, 1996. Performance and integrated operational test runs conducted during the test program provided a means for critical examination, observation, and evaluation of the vitrification system. Test data taken for each Test Instruction Procedure (TIP) was used to evaluate component performance against system design and acceptance criteria, while test observations were used to correct, modify, or improve system operation. This process was critical in establishing operating conditions for the entire vitrification process

  19. Severe fuel-damage scoping test performance

    International Nuclear Information System (INIS)

    Gruen, G.E.; Buescher, B.J.

    1983-01-01

    As a result of the Three Mile Island Unit-2 (TMI-2) accident, the Nuclear Regulatory Commission has initiated a severe fuel damage test program to evaluate fuel rod and core response during severe accidents similar to TMI-2. The first test of Phase I of this series has been successfully completed in the Power Burst Facility at the Idaho National Engineering Laboratory. Following the first test, calculations were performed using the TRAC-BD1 computer code with actual experimental boundary conditions. This paper discusses the test conduct and performance and presents the calculated and measured test bundle results. The test resulted in a slow heatup to 2000 K over about 4 h, with an accelerated reaction of the zirconium cladding at temperatures above 1600 K in the lower part or the bundle and 2000 K in the upper portion of the bundle

  20. RELATIONSHIPS BETWEEN FUNCTIONAL MOVEMENT TESTS AND PERFORMANCE TESTS IN YOUNG ELITE MALE BASKETBALL PLAYERS.

    Science.gov (United States)

    Gonzalo-Skok, Oliver; Serna, Jorge; Rhea, Matthew R; Marín, Pedro J

    2015-10-01

    Sprinting and jumping are two common and important components of high-level sport performance. The weight-bearing dorsiflexion test (WB-DF) and Star Excursion Balance Test (SEBT) are tools developed to identify athletes at risk for lower extremity injury and may be related to running and jumping performance among athletes. The purposes of the present study were: 1) to identify any relationships between functional movement tests (WB-DF and SEBT) and performance tests (jumping, sprinting and changing direction); 2) to examine any relationships between asymmetries in functional movements and performance tests. Descriptive cohort study. Fifteen elite male basketball players (age: 15.4 ± 0.9 years) were assessed during a three-week period to determine the reliability of functional screening tools and performance tests and to examine the relationships between these tests. Relative (intraclass correlation coefficient) and absolute (coefficient of variation) reliability were used to assess the reproducibility of the tests. Significant correlations were detected between certain functional movement tests and performance tests. Both left and right excursion composite scores related to slower performance times in sprint testing, demonstrating that greater dynamic reach relates to decreased quickness and acceleration among these elite basketball athletes. The various relationships between dynamic functional movement testing, speed, and jump performance provide guidance for the strength and conditioning professional when conducting and evaluating data in an effort to improve performance and reduce risk of injury. The results of the present study suggest that these functional and performance tests do not measure the same components of human movement, and could be paired as outcome measures for the clinical and sport assessment of lower extremity function. 2b.

  1. The status of the technical development for the Yamanashi Maglev test line

    Energy Technology Data Exchange (ETDEWEB)

    Nakashima, Hiroshi [Maglev Systems Development Dept., Railway Technical Research Inst., Tokyo (Japan); Seki, Akio [Linear Express Research Development Div., Central Japan Railway Co. Ltd., Tokyo (Japan)

    1996-12-31

    The superconducting maglev system has been under development for the past 25 years in Japan. In last 17 years, running test on the 7 km Miyazaki test track has yielded important data for the maglev system development. In 1990, the maglev system gained the status of one of the national - funded projects in Japan. The government authorized the 42.8 km test line in Yamanashi Prefecture and R and D entered into a new phase. This new test line is planned to go through near Tokyo on the supposed Chuo line, which is expected to be a new important line connecting Tokyo and Osaka, the central part of Japan. This fact clearly explains the role of Yamanashi test line in the future. The construction of the Yamanashi test line is energetically promoted, to start running tests in spring of 1997. The situation of the technical development of the Yamanashi test line is reviewed here. (orig.)

  2. Physical activity and cohabitation status moderate the link between diabetes mellitus and cognitive performance in a community-dwelling elderly population in Germany

    Science.gov (United States)

    Buchmann, Nikolaus; Tegeler, Christina; Steinhagen-Thiessen, Elisabeth

    2017-01-01

    Aims/Hypothesis The increasing number of people with dementia and cognitive impairments makes it essential to detect and prevent modifiable risk factors of dementia. This study focuses on type 2 diabetes mellitus, especially on undiagnosed cases and their increased risk of cognitive impairment. Furthermore, the potential of physical activity and social integration to moderate the relation between diabetes and cognitive impairment is assessed. Methods We used cross-sectional data from 1299 participants of the Berlin Aging Study II (BASE-II) aged between 60 to 84 years and performed logistic regression models to analyze the association of diabetes status, physical activity, and cohabitation status with poor cognitive performance. Cognitive performance was measured with the Consortium to Establish a Registry for Alzheimer's Disease (CERAD)-Plus test battery. Results Undiagnosed diabetes (odds ratio (OR) = 2.12, p = 0.031), physical inactivity (OR = 1.43, p = 0.008) and non-cohabiting (OR = 1.58, p = 0.002) were associated with an increased likelihood of poor cognitive performance. The highest odds were observed in participants who suffered from undiagnosed or insulin-dependent diabetes and, in addition, were inactive (undiagnosed diabetes: OR = 3.44, p = 0.003; insulin-dependent diabetes: OR = 6.19, p = 0.019) or lived alone (undiagnosed diabetes: OR = 4.46, p = 0.006; insulin-dependent diabetes: OR = 6.46 p = 0.052). Physical activity and cohabiting appeared to be beneficial. Conclusions/Interpretation Physical activity and cohabitation status moderate the link between diabetes mellitus and cognitive performance. Special attention should be paid to undiagnosed and insulin-dependent diabetes cases, which have a particularly high risk of poor cognitive performance. PMID:29073237

  3. Status report. KfK contribution to the development of DEMO-relevant test blankets for NET/ITER. Pt. 1: Self-cooled liquid metal breeder blanket. Vol. 1

    International Nuclear Information System (INIS)

    Malang, S.; Reimann, J.; Sebening, H.; Barleon, L.; Bogusch, E.; Bojarsky, E.; Borgstedt, H.U.; Buehler, L.; Casal, V.; Deckers, H.; Feuerstein, H.; Fischer, U.; Frees, G.; Graebner, H.; John, H.; Jordan, T.; Kramer, W.; Krieg, R.; Lenhart, L.; Malang, S.; Meyder, R.; Norajitra, P.; Reimann, J.; Schwenk-Ferrero, A.; Schnauder, H.; Stieglitz, R.; Oschinski, J.; Wiegner, E.

    1991-12-01

    A self-cooled liquid metal breeder blanket for a fusion DEMO-reactor and the status of the development programme is described as a part of the European development programme of DEMO relevant test blankets for NET/ITER. Volume 1 (KfK 4907) contains a summary, Volume 2 (KfK 4908) a more detailed version of the report. Both volumes contain sections on previous studies on self-cooled liquid metal breeder blankets, the reference blanket design for a DEMO-reactor, a typical test blanket design including the ancillary loop system and the building requirements for NET/ITER together with the present status of the associated R and D-programme in the fields of neutronics, magnetohydrodynamics, tritium removal and recovery, liquid metal compatibility and purification, ancillary loop system, safety and reliability. An outlook is given regarding the required R and D-programme for the self-cooled liquid metal breeder blanket prior to tests in NET/ITER and the relevant test programme to be performed in NET/ITER. (orig.) [de

  4. Upper urinary tract stone disease in patients with poor performance status: active stone removal or conservative management?

    Science.gov (United States)

    Yamashita, Shimpei; Kohjimoto, Yasuo; Hirabayashi, Yasuo; Iguchi, Takashi; Iba, Akinori; Higuchi, Masatoshi; Koike, Hiroyuki; Wakamiya, Takahito; Nishizawa, Satoshi; Hara, Isao

    2017-11-16

    It remains controversial as to whether active stone removal should be performed in patients with poor performance status because of their short life expectancy and perioperative risks. Our objectives were to evaluate treatment outcomes of active stone removal in patients with poor performance status and to compare life prognosis with those managed conservatively. We retrospectively reviewed 74 patients with Eastern Cooperative Oncology Group performance status 3 or 4 treated for upper urinary tract calculi at our four hospitals between January 2009 and March 2016. Patients were classified into either surgical treatment group or conservative management group based on the presence of active stone removal. Stone-free rate and perioperative complications in surgical treatment group were reviewed. In addition, we compared overall survival and stone-specific survival between the two groups. Cox proportional hazards analysis was performed to investigate predictors of overall survival and stone-specific survival. Fifty-two patients (70.3%) underwent active stone removal (surgical treatment group) by extracorporeal shock wave lithotripsy (n = 6), ureteroscopy (n = 39), percutaneous nephrolithotomy (n = 6) or nephrectomy (n = 1). The overall stone-free rate was 78.8% and perioperative complication was observed in nine patients (17.3%). Conservative treatment was undergone by 22 patients (29.7%) (conservative management group). Two-year overall survival rates in surgical treatment and conservative management groups were 88.0% and 38.4%, respectively (p performance status could be performed safely and effectively. Compared to conservative management, surgical stone treatment achieved longer overall survival and stone-specific survival.

  5. Performance Testing of Download Services of COSMC

    Directory of Open Access Journals (Sweden)

    Jiří Horák

    2013-11-01

    Full Text Available The paper presents results of performance tests of download services of Czech Office of Surveying, Mapping and Cadastre according to INSPIRE  requirements. Methodology of testing is explained, including monitoring performance  of reference servers. 26 millions of random requests were generated for each monitored operation, layer and coordinate system. The temporal development of performance indicators are analyzed and discussed. Results of performance tests approve the compliance with INSPIRE qualitative requirements for download services. All monitored services satisfy requirements of latency, capacity and availability. The latency and availability requirements are fulfilled with an abundant reserve. No problems in structure and content of responses were detected.

  6. System Performance and Testing

    NARCIS (Netherlands)

    Frei, U.; Oversloot, H.

    2004-01-01

    This chapter compares and contrasts the system performance of two widely used solar thermal systems using testing and simulation programs. Solar thermal systems are used in many countries for heating domestically used water. In addition to the simple thermosiphon systems, better designed pumped

  7. The development and status of performance assessment in radioactive waste disposal

    International Nuclear Information System (INIS)

    McCombie, C.; Papp, T.; Coplan, S.

    1990-01-01

    The development of formal performance assessment in radioactive waste disposal has been in progress for around 10-15 years now. The time is particularly opportune for a review of the state-of-the-art because of current changes in the status of repository planning and implementation worldwide. Several major feasibility-type studies have been completed, the first full site-specific safety analyses are being performed for engineered underground disposal facilities for L/ILW, and - for HLW - the die are now being cast by implementers and regulatory determining how the safety analyses for licensing are to be performed and assessed. The article reviews the development of performance assessment and attempts to identify some key issues occupying safety analysts and regulatory reviewers involved in waste disposal today. (author) 7 figs

  8. HUBUNGAN KUALITAS PELAYANAN, STATUS EKONOMI, STATUS PENDIDIKAN TERHADAP LOYALITAS PELANGGAN KARTU SIMPATI Dl SURAKARTA

    Directory of Open Access Journals (Sweden)

    Lailiyani Khoirannisa

    2015-07-01

    Full Text Available This study aimed to identify the relationship between service quality, economic status, educational status of Simpati card customers loyalty in Surakarta. The subjects of in this research are the Simpati card customers in Surakarta. Data were collected through questionnaires and analyzed using Multiple Linear Regression. The result of t test statistic tcount  was 6088, P.value (Sig. 0000 and the regression coefficient 0663. It means that there is an influence of quality of service (X on customer loyalty. Test results obtained by t test statistic tcount was 0228; P.value (Sig. 0820 and the regression coefficient 0560. It means that there is no influence of socioeconomic status (X on customer loyalty. Test results obtained by t test statistic tcount equals to -1820; P.value (Sig. 0071, and the regression coefficients is -0759. This indicates that there is no effect of educational Status (X₃ on custumer loyalty. The results of the regression test known value of fcount  equal to 14.118 with a significance value 0.000. This indicates an increase in the quality of service simultaneously together social status and educational status will increase customer loyalty. Results of test regression relations service quality, economic status, status education against customer loyalty card Simpati is as follow: there is a relation between service quality; there is no correlation between economic status and loyalty; there is no correlation between educational status and customer loyalty; and simultaneously, service quality, economic status, and educational status have influence on loyalty of Simpati card customers in Surakarta.

  9. Comorbidity and performance status in acute myeloid leukemia patients

    DEFF Research Database (Denmark)

    Ostgård, L S G; Nørgaard, J M; Sengeløv, H

    2015-01-01

    As the world population ages, the comorbidity burden in acute myeloid leukemia (AML) patients increases. Evidence on how to integrate comorbidity measures into clinical decision-making is sparse. We determined the prognostic impact of comorbidity and World Health Organization Performance Status (PS...... with an increased short- and long-term mortality (adjusted 90 day MR, PS⩾2=3.43 (95%CI=2.30-5.13); adjusted 91 day-3 year MR=1.35 (95%CI=1.06-1.74)). We propose that more patients with comorbidity may benefit from intensive chemotherapy.Leukemia advance online publication, 2 September 2014; doi:10.1038/leu.2014.234....

  10. Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  11. Cassini radar: Instrument description and performance status

    Science.gov (United States)

    Johnson, W. T. K.; Im, E.; Borgarelli, L.; ZampoliniFaustini, E.

    1995-01-01

    The spacecraft of the Cassini mission is planned to be launched towards Saturn in October 1997. The mission is designed to study the physical structure and chemical composition of Titan. The results of the tests performed on the Cassini radar engineering qualification model (EQM) are summarized. The approach followed in the verification and evaluation of the performance of the radio frequency subsystem EQM is presented. The results show that the instrument satisfies the most relevant mission requirements.

  12. Test anxiety, perfectionism, goal orientation, and academic performance.

    Science.gov (United States)

    Eum, KoUn; Rice, Kenneth G

    2011-03-01

    Dimensions of perfectionism and goal orientation have been reported to have differential relationships with test anxiety. However, the degree of inter-relationship between different dimensions of perfectionism, the 2 × 2 model of goal orientations proposed by Elliot and McGregor, cognitive test anxiety, and academic performance indicators is not known. Based on data from 134 university students, we conducted correlation and regression analyses to test associations between adaptive and maladaptive perfectionism, four types of goal orientations, cognitive test anxiety, and two indicators of academic performance: proximal cognitive performance on a word list recall test and distal academic performance in terms of grade point average. Cognitive test anxiety was inversely associated with both performance indicators, and positively associated with maladaptive perfectionism and avoidance goal orientations. Adaptive and maladaptive perfectionism accounted for significant variance in cognitive test anxiety after controlling for approach and avoidance goal orientations. Overall, nearly 50% of the variance in cognitive test anxiety could be attributed to gender, goal orientations, and perfectionism. Results suggested that students who are highly test anxious are likely to be women who endorse avoidance goal orientations and are maladaptively perfectionistic.

  13. Integrated process status overview

    International Nuclear Information System (INIS)

    Gertman, D.I.; Gaudio, P. Jr.

    1986-01-01

    This report summarizes findings to date with the IPSO, a large plant status overview currently under development at the OECD Halden Reactor Project. As part of a joint Halden and Combustion Engineering project, the overview is being tested in part to determine whether the large screen overview concept being entertained for use in the nuclear power plant (NPP) industry will facilitate operator performance. To this end an interactive simulation technique was used to establish a proof-of-principle test for the IPSO. Process control, operations, and human factors experts at Halden participated in the test and evaluation

  14. Performance testing With JMeter 29

    CERN Document Server

    Erinle, Bayo

    2013-01-01

    Performance Testing With JMeter 2.9 is a standard tutorial that will help you polish your fundamentals, guide you through various advanced topics, and along the process help you learn new tools and skills.This book is for developers, quality assurance engineers, testers, and test managers new to Apache JMeter, or those who are looking to get a good grounding in how to effectively use and become proficient with it. No prior testing experience is required.

  15. Addendum to ''Test Plan: Small-Scale Seal Performance Tests (SSSPT)''

    International Nuclear Information System (INIS)

    Finley, R.E.

    1992-01-01

    This document describes activities that are intended to update the data base of fluid flow measurements made on expansive salt concrete (ESC) seals as part of the Small-Scale Seal Performance Tests (SSSPT). The original plans for the SSSPT experiments are described by Stormont (1985a and 1985b). These seals have previously been tested with brine and gas during the early stages (less than 450 days) after emplacement. The purpose of this Test Plan Addendum is to detail the activities necessary to, update the gas and brine measurements previously performed on the SSSPT Series A and Series B seals and to identify the key personnel responsible for implementing these activities. This addendum describes a limited undertaking and does NOT change the scope of the original test plan

  16. STATUS OF THE ATLAS LIQUID ARGON CALORIMETER AND ITS PERFORMANCE

    CERN Document Server

    Berillari, T; The ATLAS collaboration

    2011-01-01

    The liquid argon (LAr) calorimeters are used in ATLAS for all electromagnetic and for hadron calorimetry. The LAr calorimeter system consists of an electromagnetic barrel calorimeter and two endcaps with electromagnetic, hadronic and forward calorimeters. The latest status of the detector as well as problems and solutions addressed during the last years will be presented. Aspects of operation of a large detector over a long time period will be summarized and selected topics showing the performance of the detector will be shown.

  17. ATLAS Physics Objects Status and Performance at 13 TeV

    CERN Document Server

    Riu, Imma; The ATLAS collaboration

    2015-01-01

    Important for physics analyses is the understanding and commissioning of physics objects. A first look at the 13 TeV data has proved a reasonably good Monte Carlo modelling of the objects and they have been used for first physics measurements and searches beyond the Standard Model. This talk is to be given at the Top Workshop and provides an overview of the status and performance of the physics objects with the early 13 TeV data taken in summer 2015.

  18. Upper gastrointestinal symptoms in patients with advanced cancer: relationship to nutritional and performance status.

    Science.gov (United States)

    Bovio, G; Montagna, G; Bariani, C; Baiardi, P

    2009-10-01

    The goals of the study were to determine the relationship of upper gastrointestinal symptoms with nutritional status and to assess their association with performance status in patients with advanced cancer. We studied 143 patients (50 F, 93 M, mean age 68 +/- 11 years, mean body mass index 22.39 +/- 4.3 kg/m(2)). Assessed symptoms were the following: anorexia, nausea, vomiting, dysphagia for solids, dysphagia for liquids, xerostomia, hypogeusia, dysgeusia, hiccup and chewing disturbances. We determined anthropometric parameters, daily energy intake and serum albumin, prealbumin and transferrin. The most common upper gastrointestinal symptoms were xerostomia (73%), anorexia (49%) and chewing disturbances (40%). Fifty-four percent of patients had weight loss greater than 10%. Seventy-three patients (51%) had daily energy intake lower than their resting energy expenditure. Mean serum prealbumin, albumin and transferrin were below normal range. Mean Eastern Cooperative Oncology Group performance status scale was 3.1 +/- 0.49. Symptoms were often strongly correlated, and usually, patients experienced at least three upper gastrointestinal symptoms at the same time. Anorexia, nausea and vomiting were the symptoms mostly correlated with other symptoms. A correlation was found between vomiting and hiccup. Energy intake (EI) was the nutritional parameter mostly affected by upper gastrointestinal symptoms; moreover, EI is the most predictive factor of upper gastrointestinal symptoms, particularly xerostomia, anorexia and dysphagia for solids. Upper gastrointestinal symptoms are linked to nutritional parameters: In particular, energy intake represents the most predictive variable of symptom occurrence. The performance status is not affected by upper gastrointestinal symptoms. A rigorous nutritional assessment and the managing of upper gastrointestinal symptoms are crucial in patients with advanced cancer.

  19. Drop performance test and evaluation for HANARO shutoff units

    International Nuclear Information System (INIS)

    Jung, Y. H.; Cho, Y. K.; Lee, J. H.; Choi, Y. S.; Woo, J. S.

    2004-01-01

    The function of the shutoff units of the HANARO is to rapidly insert the shutoff rod into the reactor core for safe shutdown of reactor. This paper describes drop performance test and evaluation for a shutoff unit for the technical verification of lifetime extension and localization of the HANARO shutoff units. We have performed preliminary drop performance tests for a shutoff unit at 1/2-core test loop and analyzed through the comparison with the test results performed during design verification test and the results of the periodic performance test in HANARO. It shows that the results of the local fabrication, installation and alignment for the shutoff unit meet the basic performance requirements, Furthermore, the performance evaluation method of the periodic drop test of the HANARO shutoff units is a conservative method comparing with the real drop time

  20. Performance Test of CCTV in a Test Field

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyung Min [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2011-10-15

    On April 12-13, 2010, US President Obama hosted a Nuclear Security Summit in Washington, DC, to enhance international cooperation to prevent nuclear terrorism, an issue which he has identified as the most immediate and extreme threat to global security. The Summit focused on the security of nuclear materials, nonproliferation, disarmament, and peaceful nuclear energy. At the summit, the Republic of Korea was chosen as the host of the next Summit in 2012. This series of events reflects the growing global interest on 'Nuclear Security' and as the host country of the next Nuclear Summit it is the time for Korea to strengthen the physical protection regime for nuclear facilities as a first step of securing its nuclear security capability. KINAC has been operating Test field as a mean of preparing solid backup data for reviewing and revising DBT (Design Basis Threat) and to test components of the conventional physical protection system. CCTV is a key component which is used worldwide for the assessment measure of alarms. In terms of performance test of CCTV, there are several elements such as image quality, coverage and mechanical features (speed of zoom-in-out, capture, angle shift etc.). Speaking of image quality acquired by the CCTV, the quality is subject to resolution, monitor specification, camera housing, camera mounting and lightening. Thus it is clear that performance tests on image quality should consider those factors and vary the factors respectively in order to verify the influence and the interaction among those. Nevertheless due to the restrictions of the current Test field, this paper focuses on the image quality through resolution test under the various lightening conditions

  1. Present status of ESNIT (energy selective neutron irradiation test facility) program

    International Nuclear Information System (INIS)

    Noda, K.; Ohno, H.; Sugimoto, M.; Kato, Y.; Matsuo, H.; Watanabe, K.; Kikuchi, T.; Sawai, T.; Usui, T.; Oyama, Y.; Kondo, T.

    1994-01-01

    The present status of technical studies of a high energy neutron irradiation facility, ESNIT (energy selective neutron irradiation test facility), is summarized. Technological survey and feasibility studies of ESNIT have continued since 1988. The results of technical studies of the accelerator, the target and the experimental systems in ESNIT program were reviewed by an International Advisory Committee in February 1993. Recommendations for future R and D on ESNIT program are also summarized in this paper. ((orig.))

  2. Recommended procedures for performance testing of radiobioassay laboratories: Volume 3, In vivo test phantoms

    International Nuclear Information System (INIS)

    MacLellan, J.A.; Traub, R.J.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard describes the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay performance-testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the draft ANSI N13.30 performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of test phantoms used for calibration of measurement systems for direct bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented

  3. Status, performance and scientific highlights from the MAGIC telescope system

    Energy Technology Data Exchange (ETDEWEB)

    Doert, Marlene [Technische Universitaet Dortmund (Germany); Ruhr-Universitaet Bochum (Germany); Collaboration: MAGIC-Collaboration

    2015-07-01

    The MAGIC telescopes are a system of two 17 m Imaging Air Cherenkov Telescopes, which are located at 2200 m above sea level at the Roque de Los Muchachos Observatory on the Canary Island of La Palma. In this presentation, we report on recent scientific highlights gained from MAGIC observations in the galactic and the extragalactic regime. We also present the current status and performance of the MAGIC system after major hardware upgrades in the years 2011 to 2014 and give an overview of future plans.

  4. Load responsive multilayer insulation performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Dye, S.; Kopelove, A. [Quest Thermal Group, 6452 Fig Street Suite A, Arvada, CO 80004 (United States); Mills, G. L. [Ball Aerospace and Technologies Corp, 1600 Commerce Street, Boulder, CO 80301 (United States)

    2014-01-29

    Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.

  5. Load responsive multilayer insulation performance testing

    International Nuclear Information System (INIS)

    Dye, S.; Kopelove, A.; Mills, G. L.

    2014-01-01

    Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI

  6. Preschool Inhibitory Control Predicts ADHD Group Status and Inhibitory Weakness in School.

    Science.gov (United States)

    Jacobson, Lisa A; Schneider, Heather; Mahone, E Mark

    2017-12-26

    Discriminative utility of performance measures of inhibitory control was examined in preschool children with and without ADHD to determine whether performance measures added to diagnostic prediction and to prediction of informant-rated day-to-day executive function. Children ages 4-5 years (N = 105, 61% boys; 54 ADHD, medication-naïve) were assessed using performance measures (Auditory Continuous Performance Test for Preschoolers-Commission errors, Conflicting Motor Response Test, NEPSY Statue) and caregiver (parent, teacher) ratings of inhibition (Behavior Rating Inventory of Executive Function-Preschool version). Performance measures and parent and teacher reports of inhibitory control significantly and uniquely predicted ADHD group status; however, performance measures did not add to prediction of group status beyond parent reports. Performance measures did significantly predict classroom inhibitory control (teacher ratings), over and above parent reports of inhibitory control. Performance measures of inhibitory control may be adequate predictors of ADHD status and good predictors of young children's classroom inhibitory control, demonstrating utility as components of clinical assessments. © The Author(s) 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Relationships Between Anaerobic Performance, Field Tests and Game Performance of Sitting Volleyball Players

    Directory of Open Access Journals (Sweden)

    Marszalek Jolanta

    2015-12-01

    Full Text Available The aim of this study was to evaluate relationships between anaerobic performance, field tests, game performance and anthropometric variables of sitting volleyball players. Twenty elite Polish sitting volleyball players were tested using the 30 s Wingate Anaerobic Test for arm crank ergometer and participated in six physical field tests. Heights in position to block and to spike, as well as arm reach were measured. Players were observed during the game on the court in terms of effectiveness of the serve, block, attack, receive and defense. Pearson analysis and the Spearman's rank correlation coefficient were used. The strongest correlations were found between the chest pass test and mean power and peak power (r=.846; p=.001 and r=.708; p=.0005, respectively, and also between the T-test and peak power (r= −.718; p=.001. Mean power correlated with the 3 m test (r= −.540; p=.014, the 5 m test (r= −.592; p=.006, and the T-test (r= −.582; p=.007. Peak power correlated with the 3 m test (r= −.632; p=.003, the 5 m test (r= −.613; p=.004, speed & agility (r= −.552; p=.012 and speed & endurance (r=−.546; p=.013. Significant correlations were observed between anthropometric parameters and anaerobic performance variables (p≤.001, and also between anthropometric parameters and field tests (p≤.05. Game performance and physical fitness of sitting volleyball players depended on their anthropometric variables: reach of arms, the position to block and to spike. The chest pass test could be used as a non-laboratory field test of anaerobic performance of sitting volleyball players.

  8. Developing standard performance testing procedures for material control and accounting components at a site

    International Nuclear Information System (INIS)

    Scherer, Carolynn P.; Bushlya, Anatoly V.; Efimenko, Vladimir F.; Ilyanstev, Anatoly; Regoushevsky, Victor I.

    2010-01-01

    The condition of a nuclear material control and accountability system (MC and A) and its individual components, as with any system combining technical elements and documentation, may be characterized through an aggregate of values for the various parameters that determine the system's ability to perform. The MC and A system's status may be functioning effectively, marginally or not functioning based on a summary of the values of the individual parameters. This work included a review of the following subsystems, MC and A and Detecting Material Losses, and their respective elements for the material control and accountability system: (a) Elements of the MC and A Subsystem - Information subsystem (Accountancy/Inventory), Measurement subsystem, Nuclear Material Access subsystem, including tamper-indicating device (TID) program, and Automated Information-gathering subsystem; (b) Elements for Detecting Nuclear Material Loses Subsystem - Inventory Differences, Shipper/receiver Differences, Confirmatory Measurements and differences with accounting data, and TID or Seal Violations. In order to detect the absence or loss of nuclear material there must be appropriate interactions among the elements and their respective subsystems from the list above. Additionally this work includes a review of regulatory requirements for the MC and A system component characteristics and criteria that support the evaluation of the performance of the listed components. The listed components had performance testing algorithms and procedures developed that took into consideration the regulatory criteria. The developed MC and A performance-testing procedures were the basis for a Guide for MC and A Performance Testing at the material balance areas (MBAs) of State Scientific Center of the Russian Federation - Institute for Physics and Power Engineering (SSC RF-IPPE).

  9. Proposed limiting values for performance criteria in acceptance testing of diagnostic X-ray equipment in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Baeuml, A.

    1989-01-01

    In the Federal Republic of Germany a new X-ray ordinance came into force in 1988 containing a specific paragraph on quality assurance for all medical X-ray units stipulating acceptance tests, regular checks and supervision by medical bodies and the competent authorities. Acceptance testing is to be performed by engineers from equipment suppliers of manufacturers in new and existing installations. It is expected that the service engineers will adjust the equipment in such a way as to obtain optimal performance before measurements are made, the results of which are to be stated in a certificate describing quality status of the equipment. A working group has developed guidelines for these acceptance tests. Items to be measured are reported and proposed limiting values and their tolerances are discussed. (author)

  10. Proposed limiting values for performance criteria in acceptance testing of diagnostic X-ray equipment in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Baeuml, A.

    1989-01-01

    In the Federal Republic of Germany a new X-ray ordinance came into force in 1988 containing a specific paragraph on quality assurance for all medical X-ray units stipulating acceptance tests, regular checks and supervision by medical bodies and the competent authorities. Acceptance testing is to be performed by engineers from the equipment suppliers or manufacturers in new and also existing installations. It is expected that the service engineers will adjust the equipment in such a way as to obtain optimal performance before measurements are made, the results of which are to be stated in a certificate describing the quality status of the equipment. A working group has developed guidelines for these acceptance tests. The items to be measured are reported and the proposed limiting values and their tolerances are discussed. (author)

  11. Alternative methods for skin irritation testing: the current status : ECVAM skin irritation task force report 1

    NARCIS (Netherlands)

    Botham, P.A.; Earl, L.K.; Fentem, J.H.; Roguet, R.; Sandt, J.J.M.

    1998-01-01

    The ECVAM Skin Irritation Task Force was established in November 1996, primarily to prepare a report on the current status of the development and validation of alternative tests for skin irritation and corrosion and, in particular, to identify any appropriate non-animal tests for predicting human

  12. Present status and future perspectives of research and test reactor in Japan

    International Nuclear Information System (INIS)

    Kaneko, Yoshihiko; Kaieda, Keisuke

    2000-01-01

    Since 1957, Japan Atomic Energy Research Institute (JAERI) has constructed several research and test reactors to fulfill a major role in the study of nuclear energy and fundamental research. At present four reactors, the Japan Research Reactor No. 3 and No. 4 (JRR-3M and JRR-4 respectively), the Japan Materials Testing Reactor (JMTR) and the Nuclear Safety Research Reactor (NSRR) are in operation, and a new High Temperature Engineering Test Reactor (HTTR) has recently reached first criticality and now in the power up test. In 1966, the Kyoto University built the Kyoto University Reactor (KUR) and started its operation for joint use program of the Japanese universities. This paper introduces these reactors and describes their present operational status and also efforts for aging management. The recent tendency of utilization and future perspectives is also reported. (author)

  13. Present status and future perspectives of research and test reactor in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Yoshihiko [Atomic Energy Research Laboratory, Musashi Institute of Technology, Kawasaki, Kanagawa (Japan); Kaieda, Keisuke [Department of Research Reactor, Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan)

    2000-10-01

    Since 1957, Japan Atomic Energy Research Institute (JAERI) has constructed several research and test reactors to fulfill a major role in the study of nuclear energy and fundamental research. At present four reactors, the Japan Research Reactor No. 3 and No. 4 (JRR-3M and JRR-4 respectively), the Japan Materials Testing Reactor (JMTR) and the Nuclear Safety Research Reactor (NSRR) are in operation, and a new High Temperature Engineering Test Reactor (HTTR) has recently reached first criticality and now in the power up test. In 1966, the Kyoto University built the Kyoto University Reactor (KUR) and started its operation for joint use program of the Japanese universities. This paper introduces these reactors and describes their present operational status and also efforts for aging management. The recent tendency of utilization and future perspectives is also reported. (author)

  14. Present status of high-temperature engineering test reactor (HTTR) program

    International Nuclear Information System (INIS)

    Tanaka, Toshiyuki; Baba, Osamu; Shiozawa, Shusaku; Okubo, Minoru; Tobioka, Toshiaki

    1994-01-01

    The 30MWt HTTR is a high-temperature gas-cooled reactor (HTGR), with a maximum helium coolant temperature of 950degC at the reactor outlet. The construction of the HTTR started in March 1991, with first criticality to be followed in 1998 after commissioning testing. At present the HTTR reactor building (underground part) and its containment vessel have been almost completed and its main components, such as a reactor pressure vessel (RPV), an intermediate heat exchanger, hot gas pipings and graphite core structures, are now manufacturing at their factories at the target of their installation starting in 1994. The project is intended to establish and upgrade the technology basis necessary for HTGR developments. Japan Atomic Energy Research Institute (JAERI) also plans to conduct material and fuel irradiation tests as an innovative basic research after attaining rated power and coolant temperature. Innovative basic researches are now in great request. The paper describes major features of HTTR, present status of its construction and research and test using HTTR. (author)

  15. Present status of High-Temperature engineering Test Reactor (HTTR) program

    International Nuclear Information System (INIS)

    Tanaka, Toshiyuki; Baba, Osamu; Shiozawa, Shusaku; Okubo, Minoru; Tobioka, Toshiaki

    1993-01-01

    The 30MWt HTTR is a high-temperature gas-cooled reactor (HTGR), with a maximum helium coolant temperature of 950 deg C at the reactor outlet. The construction of the HTTR started in March 1991, with first criticality to be followed in 1998 after commissioning testing. At present the HTTR reactor building (underground part) and its containment vessel have been almost completed and its main components, such as a reactor pressure vessel (RPV), an intermediate heat exchanger, hot gas pipings and graphite core structures, are now manufacturing at their factories at the target of their installation starting in 1994. The project is intended to establish and upgrade the technology basis necessary for HTGR developments. Japan Atomic Energy Research Institute (JAERI) also plans to conduct material and fuel irradiation tests as an innovative basic research after attaining rated power and coolant temperature. Innovative basic researches are now in great request. The paper describes major features of HTTR, present status of its construction and research and test plan using HTTR. (author)

  16. Testing Game-Based Performance in Team-Handball.

    Science.gov (United States)

    Wagner, Herbert; Orwat, Matthias; Hinz, Matthias; Pfusterschmied, Jürgen; Bacharach, David W; von Duvillard, Serge P; Müller, Erich

    2016-10-01

    Wagner, H, Orwat, M, Hinz, M, Pfusterschmied, J, Bacharach, DW, von Duvillard, SP, and Müller, E. Testing game-based performance in team-handball. J Strength Cond Res 30(10): 2794-2801, 2016-Team-handball is a fast paced game of defensive and offensive action that includes specific movements of jumping, passing, throwing, checking, and screening. To date and to the best of our knowledge, a game-based performance test (GBPT) for team-handball does not exist. Therefore, the aim of this study was to develop and validate such a test. Seventeen experienced team-handball players performed 2 GBPTs separated by 7 days between each test, an incremental treadmill running test, and a team-handball test game (TG) (2 × 20 minutes). Peak oxygen uptake (V[Combining Dot Above]O2peak), blood lactate concentration (BLC), heart rate (HR), sprinting time, time of offensive and defensive actions as well as running intensities, ball velocity, and jump height were measured in the game-based test. Reliability of the tests was calculated using an intraclass correlation coefficient (ICC). Additionally, we measured V[Combining Dot Above]O2peak in the incremental treadmill running test and BLC, HR, and running intensities in the team-handball TG to determine the validity of the GBPT. For the test-retest reliability, we found an ICC >0.70 for the peak BLC and HR, mean offense and defense time, as well as ball velocity that yielded an ICC >0.90 for the V[Combining Dot Above]O2peak in the GBPT. Percent walking and standing constituted 73% of total time. Moderate (18%) and high (9%) intensity running in the GBPT was similar to the team-handball TG. Our results indicated that the GBPT is a valid and reliable test to analyze team-handball performance (physiological and biomechanical variables) under conditions similar to competition.

  17. Where Lab Tests Are Performed

    Science.gov (United States)

    ... example, there may be sections that focus on microbiology, hematology, chemistry, and blood banking . Other units may perform highly specialized tests using electron microscopy and immunohistochemistry, and still others ...

  18. Performance test for a solar water heater

    Science.gov (United States)

    1979-01-01

    Two reports describe procedures and results of performance tests on domestic solar powered hot water system. Performance tests determine amount of energy collected by system, amount of energy delivered to solar source, power required to operate system and maintain proper tank temperature, overall system efficiency, and temperature distribution in tank.

  19. Do the disadvantaged legitimize the social system? A large-scale test of the status-legitimacy hypothesis.

    Science.gov (United States)

    Brandt, Mark J

    2013-05-01

    System justification theory (SJT) posits that members of low-status groups are more likely to see their social systems as legitimate than members of high-status groups because members of low-status groups experience a sense of dissonance between system motivations and self/group motivations (Jost, Pelham, Sheldon, & Sullivan, 2003). The author examined the status-legitimacy hypothesis using data from 3 representative sets of data from the United States (American National Election Studies and General Social Surveys) and throughout the world (World Values Survey; total N across studies = 151,794). Multilevel models revealed that the average effect across years in the United States and countries throughout the world was most often directly contrary to the status-legitimacy hypothesis or was practically zero. In short, the status-legitimacy effect is not a robust phenomenon. Two theoretically relevant moderator variables (inequality and civil liberties) were also tested, revealing weak evidence, null evidence, or contrary evidence to the dissonance-inspired status-legitimacy hypothesis. In sum, the status-legitimacy effect is not robust and is unlikely to be the result of dissonance. These results are used to discuss future directions for research, the current state of SJT, and the interpretation of theoretically relevant but contrary and null results. PsycINFO Database Record (c) 2013 APA, all rights reserved

  20. A systematic review of tests for lymph node status in primary endometrial cancer.

    Science.gov (United States)

    Selman, Tara J; Mann, Christopher H; Zamora, Javier; Khan, Khalid S

    2008-05-05

    The lymph node status of a patient is a key determinate in staging, prognosis and adjuvant treatment of endometrial cancer. Despite this, the potential additional morbidity associated with lymphadenectomy makes its role controversial. This study systematically reviews the accuracy literature on sentinel node biopsy; ultra sound scanning, magnetic resonance imaging (MRI) and computer tomography (CT) for determining lymph node status in endometrial cancer. Relevant articles were identified form MEDLINE (1966-2006), EMBASE (1980-2006), MEDION, the Cochrane library, hand searching of reference lists from primary articles and reviews, conference abstracts and contact with experts in the field. The review included 18 relevant primary studies (693 women). Data was extracted for study characteristics and quality. Bivariate random-effect model meta-analysis was used to estimate diagnostic accuracy of the various index tests. MRI (pooled positive LR 26.7, 95% CI 10.6 - 67.6 and negative LR 0.29 95% CI 0.17 - 0.49) and successful sentinel node biopsy (pooled positive LR 18.9 95% CI 6.7 - 53.2 and negative LR 0.22, 95% CI 0.1 - 0.48) were the most accurate tests. CT was not as accurate a test (pooled positive LR 3.8, 95% CI 2.0 - 7.3 and negative LR of 0.62, 95% CI 0.45 - 0.86. There was only one study that reported the use of ultrasound scanning. MRI and sentinel node biopsy have shown similar diagnostic accuracy in confirming lymph node status among women with primary endometrial cancer than CT scanning, although the comparisons made are indirect and hence subject to bias. MRI should be used in preference, in light of the ASTEC trial, because of its non invasive nature.

  1. A systematic review of tests for lymph node status in primary endometrial cancer

    Directory of Open Access Journals (Sweden)

    Zamora Javier

    2008-05-01

    Full Text Available Abstract Background The lymph node status of a patient is a key determinate in staging, prognosis and adjuvant treatment of endometrial cancer. Despite this, the potential additional morbidity associated with lymphadenectomy makes its role controversial. This study systematically reviews the accuracy literature on sentinel node biopsy; ultra sound scanning, magnetic resonance imaging (MRI and computer tomography (CT for determining lymph node status in endometrial cancer. Methods Relevant articles were identified form MEDLINE (1966–2006, EMBASE (1980–2006, MEDION, the Cochrane library, hand searching of reference lists from primary articles and reviews, conference abstracts and contact with experts in the field. The review included 18 relevant primary studies (693 women. Data was extracted for study characteristics and quality. Bivariate random-effect model meta-analysis was used to estimate diagnostic accuracy of the various index tests. Results MRI (pooled positive LR 26.7, 95% CI 10.6 – 67.6 and negative LR 0.29 95% CI 0.17 – 0.49 and successful sentinel node biopsy (pooled positive LR 18.9 95% CI 6.7 – 53.2 and negative LR 0.22, 95% CI 0.1 – 0.48 were the most accurate tests. CT was not as accurate a test (pooled positive LR 3.8, 95% CI 2.0 – 7.3 and negative LR of 0.62, 95% CI 0.45 – 0.86. There was only one study that reported the use of ultrasound scanning. Conclusion MRI and sentinel node biopsy have shown similar diagnostic accuracy in confirming lymph node status among women with primary endometrial cancer than CT scanning, although the comparisons made are indirect and hence subject to bias. MRI should be used in preference, in light of the ASTEC trial, because of its non invasive nature.

  2. Testing and testing positive: childhood adversities and later life HIV status among Kenyan women and their partners.

    Science.gov (United States)

    Goodman, Michael L; Raimer-Goodman, Lauren; Chen, Catherine X; Grouls, Astrid; Gitari, Stanley; Keiser, Philip H

    2017-12-01

    Adverse childhood experiences are a critical feature of lifelong health. No research assesses whether childhood adversities predict HIV-testing behaviors, and little research analyzes childhood adversities and later life HIV status in sub-Saharan Africa. We use regression models with cross-sectional data from a representative sample (n = 1974) to analyze whether adverse childhood experiences, separately or as cumulative exposures, predict reports of later life HIV testing and testing HIV+ among semi-rural Kenyan women and their partners. No significant correlation was observed between thirteen cumulative childhood adversities and reporting prior HIV testing for respondent or partner. Separately, childhood sexual abuse and emotional neglect predicted lower odds of reporting having previously been tested for HIV. Witnessing household violence during one's childhood predicted significantly higher odds of reporting HIV+. Sexual abuse predicted higher odds of reporting a partner tested HIV+. Preventing sexual abuse and household violence may improve HIV testing and test outcomes among Kenyan women. More research is required to understand pathways between adverse childhood experiences and partner selection within Kenya and sub-Saharan Africa, and data presented here suggest understanding pathways may help improve HIV outcomes. © The Author 2016. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. GEM: Performance and aging tests

    International Nuclear Information System (INIS)

    Cho, H.S.; Kadyk, J.; Han, S.H.; Hong, W.S.; Perez-Mendez, V.; Wenzel, W.; Pitts, K.; Martin, M.D.; Hutchins, J.B.

    1999-01-01

    Performance and aging tests have been done to characterize Gas Electron Multipliers (GEMs), including further design improvements such as a thicker GEM and a closed GEM. Since the effective GEM gain is typically smaller than the absolute GEM gain, due to trapping of avalanche electrons at the bottom GEM electrode, the authors performed field simulations and measurements for better understanding, and discuss methods to eliminate this effect. Other performance parameters of the GEMs are also presented, including absolute GEM gain, short-term and long-term gain stabilities

  4. Performance testing framework for smart grid communication network

    International Nuclear Information System (INIS)

    Quang, D N; See, O H; Chee, L L; Xuen, C Y; Karuppiah, S

    2013-01-01

    Smart grid communication network is comprised of different communication mediums and technologies. Performance evaluation is one of the main concerns in smart grid communication system. In any smart grid communication implementation, to determine the performance factor of the network, a testing of an end-to-end process flow is required. Therefore, an effective and coordinated testing procedure plays a crucial role in evaluating the performance of smart grid communications. In this paper, a testing framework is proposed as a guideline to analyze and assess the performance of smart grid communication network.

  5. The influence of shyness on children's test performance.

    Science.gov (United States)

    Crozier, W Ray; Hostettler, Kirsten

    2003-09-01

    Research has shown that shy children differ from their peers not only in their use of language in routine social encounters but also in formal assessments of their language development, including psychometric tests of vocabulary. There has been little examination of factors contributing to these individual differences. To investigate cognitive-competence and social anxiety interpretations of differences in children's performance on tests of vocabulary. To examine the performance of shy and less shy children under different conditions of test administration, individually with an examiner or among their peers within the familiar classroom setting. The sample consisted of 240 Year 5 pupils (122 male, 118 female) from 24 primary schools. Shy and less shy children, identified by teacher nomination and checklist ratings, completed vocabulary and mental arithmetic tests in one of three conditions, in a between-subjects design. The conditions varied individual and group administration, and oral and written responses. The conditions of test administration influenced the vocabulary test performance of shy children. They performed significantly more poorly than their peers in the two face-to-face conditions but not in the group test condition. A comparable trend for the arithmetic test was not statistically significant. Across the sample as a whole, shyness correlated significantly with test scores. Shyness does influence children's cognitive test performance and its impact is larger when children are tested face-to-face rather than in a more anonymous group setting. The results are of significance for theories of shyness and have implications for the assessment of schoolchildren.

  6. Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test

    International Nuclear Information System (INIS)

    Bae, Kyoo Whan; Song, Jin Ho; Chung, Young Jong; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring in the downcomer with limited budget and time, the separate effects test focusing on this region is considered to be effective and the conceptual test facility based on this recommended. For this test facility the test initial and boundary conditions are developed using the CEFLASH-4AS/REM analysis results that will be used as input for the preliminary test requirements. The final test requirements will be developed through the further discussions with the test performance group. (Author). 10 refs., 18 tabs., 4 figs

  7. Dual Testing Algorithm of BED-CEIA and AxSYM Avidity Index Assays Performs Best in Identifying Recent HIV Infection in a Sample of Rwandan Sex Workers

    NARCIS (Netherlands)

    Braunstein, Sarah L.; Nash, Denis; Kim, Andrea A.; Ford, Ken; Mwambarangwe, Lambert; Ingabire, Chantal M.; Vyankandondera, Joseph; van de Wijgert, Janneke H. H. M.

    2011-01-01

    To assess the performance of BED-CEIA (BED) and AxSYM Avidity Index (Ax-AI) assays in estimating HIV incidence among female sex workers (FSW) in Kigali, Rwanda. Eight hundred FSW of unknown HIV status were HIV tested; HIV-positive women had BED and Ax-AI testing at baseline and ≥12 months later to

  8. Tests Performed on Hydraulic Turbines at Commissioning or after Capital Repairs. Part II. Tests Performed on a 6.5 MW Kaplan Turbine

    Directory of Open Access Journals (Sweden)

    Adrian Cuzmoş

    2015-07-01

    Full Text Available The paper presents the tests performed on a hydraulic turbine on commissioning, the devices, test methods and the results obtained from the respective tests, as well as the conclusions and recommendations resulted from these tests. This kind of tests can be performed for the verification of guarantees.

  9. Performance testing of extremity dosimeters, Study 2

    International Nuclear Information System (INIS)

    Harty, R.; Reece, W.D.; Hooker, C.D.

    1990-04-01

    The Health Physics Society Standards Committee (HPSSC) Working Group on Performance Testing of Extremity Dosimeters has issued a draft of a proposed standard for extremity dosimeters. The draft standard proposes methods to be used for testing dosimetry systems that determine occupational radiation dose to the extremities and the performance criterion used to determine compliance with the standard. Pacific Northwest Laboratory (PNL) has conducted two separate evaluations of the performance of extremity dosimeter processors to determine the appropriateness of the draft standard, as well as to obtain information regarding the performance of extremity dosimeters. Based on the information obtained during the facility visits and the results obtained from the performance testing, it was recommended that changes be made to ensure that the draft standard is appropriate for extremity dosimeters. The changes include: subdividing the mixture category and the beta particle category; eliminating the neutron category until appropriate flux-to-dose equivalent conversion factors are derived; and changing the tolerance level for the performance criterion to provide consistency with the performance criterion for whole body dosimeters, and to avoid making the draft standard overly difficult for processors of extremity dosimeters to pass. 20 refs., 10 figs., 6 tabs

  10. The Effects of Humor on Test Anxiety and Test Performance

    Science.gov (United States)

    Tali, Glenda

    2017-01-01

    Testing in an academic setting provokes anxiety in all students in higher education, particularly nursing students. When students experience high levels of anxiety, the resulting decline in test performance often does not represent an accurate assessment of students' academic achievement. This quantitative, experimental study examined the effects…

  11. Compressible Fluid Suspension Performance Testing

    National Research Council Canada - National Science Library

    Hoogterp, Francis

    2003-01-01

    ... compressible fluid suspension system that was designed and installed on the vehicle by DTI. The purpose of the tests was to evaluate the possible performance benefits of the compressible fluid suspension system...

  12. Work zone performance measures pilot test.

    Science.gov (United States)

    2011-04-01

    Currently, a well-defined and validated set of metrics to use in monitoring work zone performance do not : exist. This pilot test was conducted to assist state DOTs in identifying what work zone performance : measures can and should be targeted, what...

  13. Status report. KfK contribution to the development of DEMO-relevant test blankets for NET/ITER. Pt. 1: Self-cooled liquid metal breeder blanket. Vol. 2. Detailed version

    International Nuclear Information System (INIS)

    John, H.; Malang, S.; Sebening, H.

    1991-12-01

    A self-cooled liquid metal breeder blanket for a fusion DEMO-reactor and the status of the development programme is described as a part of the European development programme of DEMO relevant test blankets for NET/ITER. Volume 1 (KfK 4907) contains a summary. Volume 2 (KfK 4908) a more detailed version of the report. Both volumes contain sections on previous studies on self-cooled liquid metal breeder blankets, the reference blanket design for a DEMO-reactor, a typical test blanket design including the ancillary loop system and the building requirements for NET/ITER together with the present status of the associated RandD-programme in the fields of neutronics, magnetohydrodynamics, tritium removal and recovery, liquid metal compatibility and purification, ancillary loop system, safety and reliability. An outlook is given regarding the required RandD-programme for the self-cooled liquid metal breeder blanket prior to tests in NET/ITER and the relevant test programme to be performed in NET/ITER. (orig.) [de

  14. Effect of a multiple-micronutrient-fortified fruit powder beverage on the nutrition status, physical fitness, and cognitive performance of schoolchildren in the Philippines.

    Science.gov (United States)

    Solon, Florentino S; Sarol, Jesus N; Bernardo, Allan B I; Solon, Juan Antonio A; Mehansho, Haile; Sanchez-Fermin, Liza E; Wambangco, Lorena S; Juhlin, Kenton D

    2003-12-01

    This study aimed to determine the effect of a multiple-micronutrient-fortified beverage on the micronutrient status, physical fitness, and cognitive performance of schoolchildren. The study was a randomized, double-blind, placebo-controlled trial of schoolchildren assigned to receive either the fortified or nonfortified beverage with or without anthelmintic therapy. Data on hemoglobin level, urinary iodine excretion (UIE) level, physical fitness, and cognitive performance were collected at baseline and at 16 weeks post-intervention. The fortified beverage significantly improved iron status among the subjects that had hemoglobin levels performance (nonverbal mental ability score). The study showed that consumption of a multiple-micronutrient-fortified beverage for 16 weeks had significant effects on iron status, iodine status, physical fitness, and cognitive performance among iron- and/or iodine-deficient Filipino schoolchildren. Anthelmintic therapy improved iron status of anemic children and iodine status of the iron-adequate children at baseline but it had no effect on physical fitness and cognitive performance. The results from the clinical study showed that a multiple-micronutrient-fortified beverage could play an important role in preventing and controlling micronutrient deficiencies.

  15. Predicting outcome of status epilepticus.

    Science.gov (United States)

    Leitinger, M; Kalss, G; Rohracher, A; Pilz, G; Novak, H; Höfler, J; Deak, I; Kuchukhidze, G; Dobesberger, J; Wakonig, A; Trinka, E

    2015-08-01

    Status epilepticus (SE) is a frequent neurological emergency complicated by high mortality and often poor functional outcome in survivors. The aim of this study was to review available clinical scores to predict outcome. Literature review. PubMed Search terms were "score", "outcome", and "status epilepticus" (April 9th 2015). Publications with abstracts available in English, no other language restrictions, or any restrictions concerning investigated patients were included. Two scores were identified: "Status Epilepticus Severity Score--STESS" and "Epidemiology based Mortality score in SE--EMSE". A comprehensive comparison of test parameters concerning performance, options, and limitations was performed. Epidemiology based Mortality score in SE allows detailed individualization of risk factors and is significantly superior to STESS in a retrospective explorative study. In particular, EMSE is very good at detection of good and bad outcome, whereas STESS detecting bad outcome is limited by a ceiling effect and uncertainty of correct cutoff value. Epidemiology based Mortality score in SE can be adapted to different regions in the world and to advances in medicine, as new data emerge. In addition, we designed a reporting standard for status epilepticus to enhance acquisition and communication of outcome relevant data. A data acquisition sheet used from patient admission in emergency room, from the EEG lab to intensive care unit, is provided for optimized data collection. Status Epilepticus Severity Score is easy to perform and predicts bad outcome, but has a low predictive value for good outcomes. Epidemiology based Mortality score in SE is superior to STESS in predicting good or bad outcome but needs marginally more time to perform. Epidemiology based Mortality score in SE may prove very useful for risk stratification in interventional studies and is recommended for individual outcome prediction. Prospective validation in different cohorts is needed for EMSE, whereas

  16. 198Au grain implantation for early tongue cancer in patients of advanced age or poor performance status

    International Nuclear Information System (INIS)

    Ryu, Yoshiharu; Shibuya, Hitoshi; Hayashi, Keiji

    2013-01-01

    Brachytherapy using 198 Au grains is minimally invasive and the only curative treatment for early tongue cancer in patients of advanced age or poor performance status available in our institution. From March 1993 to February 2008, 198 Au grains were used to treat a group of 96 Stage I–II tongue cancer patients who could not undergo surgery or brachytherapy using 192 Ir pins because of an advanced age (≥75 years) or poor performance status (≥2). The patients were followed for 3.9 ± 3.3 years, and the cause-specific survival and local control rates were determined. Survival analyses were performed using the Kaplan-Meier method, and univariate and multivariate analyses were performed using the Cox proportional hazard model. The results were compared with those for a group of 193 early tongue-cancer patients who underwent treatment using iridium pins. The 5-year cause-specific survival and local control rates of the 198 Au grains group were 71% and 68%, respectively, both of which were 16% lower than the corresponding rates for the 192 Ir pins group. Our study demonstrated that as the last curative treatment available, 198 Au grain implantation could be used to achieve moderate treatment results for early tongue cancer in patients of advanced age or poor performance status

  17. Performance Prediction of Centrifugal Compressor for Drop-In Testing Using Low Global Warming Potential Alternative Refrigerants and Performance Test Codes

    Directory of Open Access Journals (Sweden)

    Joo Hoon Park

    2017-12-01

    Full Text Available As environmental regulations to stall global warming are strengthened around the world, studies using newly developed low global warming potential (GWP alternative refrigerants are increasing. In this study, substitute refrigerants, R-1234ze (E and R-1233zd (E, were used in the centrifugal compressor of an R-134a 2-stage centrifugal chiller with a fixed rotational speed. Performance predictions and thermodynamic analyses of the centrifugal compressor for drop-in testing were performed. A performance prediction method based on the existing ASME PTC-10 performance test code was proposed. The proposed method yielded the expected operating area and operating point of the centrifugal compressor with alternative refrigerants. The thermodynamic performance of the first and second stages of the centrifugal compressor was calculated as the polytropic state. To verify the suitability of the proposed method, the drop-in test results of the two alternative refrigerants were compared. The predicted operating range based on the permissible deviation of ASME PTC-10 confirmed that the temperature difference was very small at the same efficiency. Because the drop-in test of R-1234ze (E was performed within the expected operating range, the centrifugal compressor using R-1234ze (E is considered well predicted. However, the predictions of the operating point and operating range of R-1233zd (E were lower than those of the drop-in test. The proposed performance prediction method will assist in understanding thermodynamic performance at the expected operating point and operating area of a centrifugal compressor using alternative gases based on limited design and structure information.

  18. Status and Plans for a Superconducting RF Accelerator Test Facility at Fermilab

    International Nuclear Information System (INIS)

    Andrews, R.; Baffes, C.M.; Carlson, K.; Chase, B.; Church, M.D.; Harms, E.R.; Klebaner, A.L.; Leibfritz, J.R.; Martinez, A.; Nagaitsev, S.; Nobrega, L.E.

    2012-01-01

    The Advanced Superconducting Test Accelerator (ASTA) is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beam lines for testing diagnostics and conducting various beam tests, and a high power beam dump. When completed, it is envisioned that this facility will initially be capable of generating a 750 MeV electron beam with ILC beam intensity. An expansion of this facility was recently completed that will provide the capability to upgrade the accelerator to a total beam energy of 1.5 GeV. Two new buildings were also constructed adjacent to the ASTA facility to house a new cryogenic plant and multiple superconducting RF (SRF) cryomodule test stands. In addition to testing accelerator components, this facility will be used to test RF power systems, instrumentation, and control systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

  19. Status of endangered and threatened plant species on Tonopah Test Range: a survey

    International Nuclear Information System (INIS)

    Rhoads, W.A.; Cochrane, S.A.; Williams, M.P.

    1979-10-01

    Six species under consideration by the US Fish and Wildlife Service (FWS) for endangered or threatened status were found on or near the Tonopah Test Range (TTR) in southern central Nevada. Based on recognized threats to these species, their overall distribution, rarity, and other factors, status recommendations were prepared for Sandia Corporation. In addition, ten species that occur in the vicinity of TTR, and which may yet be found on TTR, are discussed in brief. Each species is discussed in relation to distribution, rarity, taxonomy, habitat requirements, endangerment, assessment of status, and proposed protection and monitoring needs. Construction activities and off-road vehicle travel are the most prominent man-caused threats to species on TTR; habitat destruction by trampling and over-grazing by feral horses and non-permit cattle significantly modifies habitats of certain species. We recommend two kinds of protective measures. First is the planning of activities so that habitats, particularly the suggested protected habitats, are not disturbed. Second, and directed to the same end, off-road traffic should be curtailed in the regions of the proposed protected habitats

  20. Personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, Christopher G.

    2008-01-01

    The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11. Now in it's fourth edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Laboratory Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by U.S. Nuclear Regulatory Commission (NRC) regulations. The U.S. Department of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Department of Energy Laboratory Accreditation Program (DOELAP). One of the goals of this current revision was the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonization to U.S. personal dosemeter performance testing. The testing philosophy of ANSI/HPS N13.11 has always combined elements of type testing and routine performance testing and is thus different from the testing philosophy used in the rest of the world. In this paper, the history of performance testing in the U.S. is briefly reviewed. Also described is the revision that produced the fourth edition of this standard, which has taken place over the last three years (2005-2008) by a working group representing national standards laboratories, government laboratories, the military, dosimetry vendors, universities and the nuclear power industry. (author)

  1. Pioneer Robot Testing Program and Status

    International Nuclear Information System (INIS)

    Herndon, J.N.

    2001-01-01

    The U.S. Department of Energy (USDOE) and Ukraine established a joint program in 1997 to address the need for remotely operated systems for unstructured environments in Ukraine such as the highly hazardous conditions inside the failed Chernobyl Nuclear Power Plant (ChNPP) Unit 4, or Shelter Object. The environment inside Shelter Object is extremely hazardous due to ionizing radiation fields, high airborne contamination, and major industrial safety issues. Although Ukrainian workers have explored and mapped much of the internals of Unit 4 in the time since the accident during the morning hours of April 26, 1986, there remain areas where humans have not entered to this date. Based on the agreement between USDOE and Ukraine, the USDOE, in cooperation with the U.S. National Aeronautics and Space Administration (NASA), developed the Pioneer Robot and has provided it to the ChNPP within the framework of international technical assistance. Pioneer is capable of mobile platform movement and manipulation under teleoperated control, 3-dimensional mapping, and environmental data collection. The Pioneer is radiation hardened for conditions like those of Shelter Object. Pioneer has been evaluated on site in Ukraine for use in both the Shelter Object environment and the more general conditions of ChNPP decommissioning. This paper summarizes the results of these testing activities and describes the status and near-term activities in support of the Pioneer Robot integration into Ukraine

  2. Performance of smokeless gasoline fire test facility

    International Nuclear Information System (INIS)

    Griffin, J.F.; Watkins, R.A.

    1978-01-01

    Packaging for radioactive materials must perform satisfactorily when subjected to temperatures simulating an accident involving a fire. The new thermal test facility has proved to be a reliable method for satisfactorily performing the required test. The flame provides sufficient heat to assure that the test is valid, and the temperature can be controlled satisfactorily. Also, the air and water mist systems virtually eliminate any smoke and thereby exceed the local EPA requirements. The combination of the two systems provides an inexpensive, low maintenance technique for elimination of the smoke plume

  3. The development and status of performance assessment in radioactive waste disposal

    International Nuclear Information System (INIS)

    McCombie, C.; Papp, T.; Coplan, S.

    1990-01-01

    The development of formal performance assessment in radioactive waste disposal has been in progress for around 10-15 years now. The time is particularly opportune for a review of the state-of-the-art because of current changes in the status of repository planning and implementation world-wide. Several major feasibility-type studies have been completed, the first full site-specific safety analyses are being performed for engineered underground disposal facilities for L/ILW, and - for HLW - the die are now being cast by implementers and regulators determining how the safety analyses for licensing are to be performed and assessed. This introductory paper reviews the development of performance assessment, including a reiteration of the aims and a recapitulation of the technical progress and achievements to date. The most important purpose, however, is to identify some key issues occupying safety analysts and regulatory reviewers involved in waste disposal today. The objective is to present the generally accepted consensus on the state of the art in performance assessment. 40 refs., 2 figs

  4. Expectancy of an open-book test decreases performance on a delayed closed-book test.

    Science.gov (United States)

    Agarwal, Pooja K; Roediger, Henry L

    2011-11-01

    Two experiments examined the influence of practice with, and the expectancy of, open-book tests (students viewed studied material while taking the test) versus closed-book tests (students completed the test without viewing the studied material) on delayed retention and transfer. Using GRE materials specifically designed for open-book testing, participants studied passages and then took initial open- or closed-book tests. Open-book testing led to better initial performance than closed-book testing, but on a delayed criterial (closed-book) test both types of testing produced similar retention after a two-day delay in Experiment 1. In Experiment 2 participants were informed in advance about the type of delayed criterial test to expect (open- or closed-book). Expecting an open-book test (relative to a closed-book test) decreased participants' time spent studying and their delayed test performance on closed-book comprehension and transfer tests, demonstrating that test expectancy can influence long-term learning. Expectancy of open-book tests may impair long-term retention and transfer compared to closed-book tests, despite superior initial performance on open-book tests and students' preference for open-book tests.

  5. Enhancement on Wingate Anaerobic Test Performance With Hyperventilation.

    Science.gov (United States)

    Leithäuser, Renate M; Böning, Dieter; Hütler, Matthias; Beneke, Ralph

    2016-07-01

    Relatively long-lasting metabolic alkalizing procedures such as bicarbonate ingestion have potential for improving performance in long-sprint to middle-distance events. Within a few minutes, hyperventilation can induce respiratory alkalosis. However, corresponding performance effects are missing or equivocal at best. To test a potential performance-enhancing effect of respiratory alkalosis in a 30-s Wingate Anaerobic Test (WAnT). 10 men (mean ± SD age 26.6 ± 4.9 y, height 184.4 ± 6.1 cm, body-mass test 1 80.7 ± 7.7 kg, body-mass test 2 80.4 ± 7.2 kg, peak oxygen uptake 3.95 ± 0.43 L/min) performed 2 WAnTs, 1 with and 1 without a standardized 15-min hyperventilation program pre-WAnT in randomized order separated by 1 wk. Compared with the control condition, hyperventilation reduced (all P respiratory alkalosis can enhance WAnT cycling sprint performance well in the magnitude of what is seen after successful bicarbonate ingestion.

  6. On the Safety and Performance Demonstration Tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and Validation and Verification of Computational Codes

    Directory of Open Access Journals (Sweden)

    Jong-Bum Kim

    2016-10-01

    Full Text Available The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR has been developed and the validation and verification (V&V activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1, produced satisfactory results, which were used for the computer codes V&V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

  7. On the safety and performance demonstration tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and validation and verification of computational codes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jeong, Ji Young; Lee, Tae Ho; Kim, Sung Kyun; Euh, Dong Jin; Joo, Hyung Kook [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V and V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V and V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

  8. On the safety and performance demonstration tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and validation and verification of computational codes

    International Nuclear Information System (INIS)

    Kim, Jong Bum; Jeong, Ji Young; Lee, Tae Ho; Kim, Sung Kyun; Euh, Dong Jin; Joo, Hyung Kook

    2016-01-01

    The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V and V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V and V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results

  9. The effect of pre-exercise ingestion of corinthian currant on endurance performance and blood redox status.

    Science.gov (United States)

    Deli, Chariklia K; Poulios, Athanasios; Georgakouli, Kalliopi; Papanikolaou, Konstantinos; Papoutsis, Alexandros; Selemekou, Maria; Karathanos, Vaios T; Draganidis, Dimitris; Tsiokanos, Athanasios; Koutedakis, Yiannis; Fatouros, Ioannis G; Jamurtas, Athanasios Z

    2018-02-22

    The present study investigated the effect of Corinthian currant pre-exercise supplementation on metabolism, performance and blood redox status during, and after prolonged exercise. Eleven healthy participants (21-45y) performed a 90-min constant-intensity (60-70% VO 2max ) submaximal-trial, plus a time-trial (TT) to exhaustion (95% VO 2max ) after consuming an isocaloric (1.5g CHO/kg BM) amount of randomly assigned Corinthian currant or glucose-drink, or water (control). Blood was drawn at baseline, pre-exercise, 30min, 60min, 90min of submaximal-trial, post-TT, and 1h post-TT. Post-ingestion blood glucose (GLU) under Corinthian currant was higher compared with water, and similar compared with glucose-drink throughout the study. Respiratory quotient under Corinthian currant was similar with glucose-drink and higher than water throughout the submaximal trial. Accordingly, higher CHO and lower fat oxidation were observed under Corinthian currant compared with water. The TT performance was similar between Corinthian currant, glucose-drink and water. Redox status were similar under all three conditions. Reduced glutathione (GSH) declined while total antioxidant capacity (TAC) and uric acid increased during exercise. GSH and TAC returned to baseline, while uric acid remained increased the following 1h. Corinthian currant, although did not alter exercise-mediated redox status changes and performance, was equally effective to a glucose-drink in maintaining GLU levels during prolonged cycling.

  10. Basic biochemical, hematological and hormonal parameters for monitoring the health and nutritional status in athletes

    Directory of Open Access Journals (Sweden)

    Aritz Urdampilleta

    2014-09-01

    Full Text Available Sporting competitions are becoming more demanding in terms of intensity of effort, and this means controlling all aspects that affect athletic performance. Food, hydration and supplementation, before, during and after training or competition directly affect health, body composition, performance and recovery of the athlete. The assessment of nutritional status is required for proper advising of the athlete, through blood tests to control the process of adaptation to training. The aim of this paper is to provide practical tools for dietitiansnutritionists to control the health and nutritional status of athletes, as well as monitoring their adaptation to workloads and competition periods. Performing analytical tests to control of protein metabolism, lipid profile, ions, blood tests and iron metabolism, in addition to review some hormonal parameters, may be of interest in order to observe the potential existence of overtraining states. The correct understanding and interpretation of laboratory tests (under sports doctor’s supervision will be most important and useful for dietitiansnutritionists, performing dietary and nutritional advice to athletes, because it will determine the status of the athlete and propose different individual feeding strategies depending on the training phase and response.

  11. Motivation and Test Anxiety in Test Performance across Three Testing Contexts: The CAEL, CET, and GEPT

    Science.gov (United States)

    Cheng, Liying; Klinger, Don; Fox, Janna; Doe, Christine; Jin, Yan; Wu, Jessica

    2014-01-01

    This study examined test-takers' motivation, test anxiety, and test performance across a range of social and educational contexts in three high-stakes language tests: the Canadian Academic English Language (CAEL) Assessment in Canada, the College English Test (CET) in the People's Republic of China, and the General English Proficiency Test (GEPT)…

  12. Summary of functional and performance test procedures

    DEFF Research Database (Denmark)

    Mitzel, Jens; Gülzow, Erich; Friedrich, K. Andreas

    Different Test Modules (TM) are defined for the functional and performance characterization of a PEMFC stack. The master document TM2.00 defines requirements and methodology for parameter variation, stability and data acquisition.......Different Test Modules (TM) are defined for the functional and performance characterization of a PEMFC stack. The master document TM2.00 defines requirements and methodology for parameter variation, stability and data acquisition....

  13. Quality of life and performance status in patients with pancreatic and periampullary tumors

    International Nuclear Information System (INIS)

    Velanovich, V.; Wollner, I.

    2011-01-01

    The background of this study was to determine if pretreatment quality of life is associated with performance status in patients with pancreatic and periampullary tumors. Eighty consecutive patients evaluated for surgical treatment of pancreatic or periampullary tumors completed the social functioning SF-36, a generic quality of life instrument. This instrument measures 8 domains of quality of life: physical functioning (PF), role-physical (RP), role-emotional, bodily pain, vitality, mental health, social functioning, and general health (GH). The best possible score is 100 and the worst possible score is 0. Each patient was then assigned a Karnofsky performance score (KPS), with the best possible score of 100 (normal, no complaints, no evidence of disease) and worst score of 0 (dead). Data recorded included age, gender, pathology, stage, resection, use of chemotherapy, and radiation therapy. Statistical analysis was done using single and multiple linear regression analysis, correlation coefficients (r) and coefficient of determination (r 2 ). KPS was significantly associated with all domains of the SF-36 by single linear regression. By multiple linear regression, KPS was significantly associated with the PF domain (p 2 values) suggest that there are additional factors determining both quality of life and performance status in patients with pancreatic and periampullary tumors. (author)

  14. The SSG Wave Energy Converter: Performance, Status and Recent Developments

    Directory of Open Access Journals (Sweden)

    Mariano Buccino

    2012-01-01

    Full Text Available The Sea-wave Slot-cone Generator (SSG is a Wave Energy Converter based on the wave overtopping principle; it employs several reservoirs placed on top of each other, in which the energy of incoming waves is stored as potential energy. Then, the captured water runs through turbines for electricity production. The system works under a wide spectrum of different wave conditions, giving a high overall efficiency. It can be suitable for shoreline and breakwater applications and presents particular advantages, such as sharing structure costs, availability of grid connection and recirculation of water inside the harbor, as the outlet of the turbines is on the rear part of the system. Recently, plans for the SSG pilot installations are in progress at the Svaaheia site (Norway, the port of Hanstholm (Denmark and the port of Garibaldi (Oregon, USA. In the last-mentioned two projects, the Sea-wave Slot-cone Generator technology is integrated into the outer harbor breakwater and jetty reconstruction projects. In the last years extensive studies have been performed on the hydraulic and the structural response of this converter, with the aim of optimizing the design process. The investigations have been conducted by physical model tests and numerical simulations and many results have been published on both conference proceedings and journals. The main scope of this paper is reviewing the most significant findings, to provide the reader with an organic overview on the present status of knowledge.

  15. Primary central nervous system lymphoma: age and performance status are more important than treatment modality

    International Nuclear Information System (INIS)

    Corry, June; Smith, Jennifer G.; Wirth, Andrew; Quong, George; Liew, Kuen Hoe

    1998-01-01

    Purpose: To assess prognostic factors and treatment modalities of patients with primary central nervous system lymphoma (PCNSL) in terms of response rates, patterns of failure and overall survival. Methods and Materials: Sixty-two patients presenting with PCNSL between 1982 and 1994 at Peter MacCallum Cancer Institute with no evidence of human immunodeficiency virus infection were included in the study. Their median age was 60 years; World Health Organisation (WHO) performance status was ≥2 in 85%. All patients were planned to receive whole brain irradiation; 7 also received spinal irradiation. The median planned dose to the target volume was 50.4 Gy. Twenty patients were planned to receive chemotherapy as well. Patients were followed up to June 20, 1995, giving a median follow-up for 14 surviving patients of 5.4 years, range 0.3 to 10.2 years. Results: The clinical response rate to treatment was 77% [95% confidence interval (CI) 65 to 87%]. The estimated median overall survival was 20.6 months (CI 12.4 to 33.4 months). On univariate analysis male gender, age <60 years, WHO performance status ≤1, treatment to the target volume ≥45 Gy, and treatment with additional chemotherapy, were associated with a significantly better overall survival (p < 0.05). On multivariate analysis only age and performance status remained significant prognostic variables. Relapse involved the central nervous system or cerebrospinal fluid (CSF) in all patients with known sites of relapse except three who had ocular relapse only. There was a low incidence of relapse in the initial brain site (23% of known cases) and a high incidence (50%) of CSF/spinal cord relapse. Of 48 deaths, 15 were related to initial or subsequent treatment. Conclusions: Patient outcome is strongly influenced by age and performance status. Studies suggesting better survival for patients treated with chemoradiation may reflect patient selection rather than treatment variables. Optimal management remains to be

  16. Irradiation test and performance evaluation of DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Song, K. C.; Moon, J. S.

    2002-05-01

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  17. High School Students' Performance on Vandenberg's Mental Rotations Test: Art Ability, Gender, Activities, Academic Performance, Strategies, and Ease of Taking the Test.

    Science.gov (United States)

    Gurny, Helen Graham

    This study tested whether mental rotation performance of 186 high school students (80 males and 106 females) in grades 9 through 12 in art and nonart classes on Vandenbergs Mental Rotations test (S. Vandenberg and Kuse, 1978) was affected by gender, visual-spatial activities, strategies used while performing the test, and the ease of test taking.…

  18. Impact of Multi-Micronutrient-Fortified Rice on Micronutrient Status, Health, and Cognitive Performance in Schoolchildren in Cambodia

    DEFF Research Database (Denmark)

    Khov, Kuong

    ferritin concentrations nutritional status of school-age children as well as the reasons of iron deficiency. Food fortification...... with multiple micronutrients has the potential to improve micronutrient status, growth and cognitive performance, and reduce morbidity incidence in developing countries. In Cambodia, rice is a staple food, and therefore fortified rice with multiple micronutrients could be a promising strategy to reduce...... the prevalence of micronutrient deficiencies. However, few studies have investigated the impact of fortified rice on micronutrient status, health and cognitive development in school-age children. Therefore, the aim of this PhD study is to evaluate the impact of fortified rice on nutritional status, health...

  19. NNWSI waste form performance test development

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.

    1984-01-01

    A test method has been developed to measure the release of radionuclides from the waste package under simulated NNWSI repository conditions, and to provide information concerning materials interactions that may occur in the repository. Data from 13 weeks of unsaturated testing are discussed and compared to that from a 13-week analog test. The data indicate that the waste form test is capable of producing consistent, reproducible results that will be useful in evaluating the role of the waste in the long-term performance of the repository. 6 references, 3 figures

  20. Relationship between nutritional status and the Glasgow Prognostic Score in patients with colorectal cancer.

    Science.gov (United States)

    Maurício, Sílvia Fernandes; da Silva, Jacqueline Braga; Bering, Tatiana; Correia, Maria Isabel Toulson Davisson

    2013-04-01

    The association between nutritional status and inflammation was assessed in patients with colorectal cancer and to verify their association with complications during anticancer treatment. The agreement between the Subjective Global Assessment (SGA) and different nutritional assessment methods was also evaluated. A cross-sectional, prospective, and descriptive study was performed. The nutritional status was defined by the SGA and the severity of inflammation was defined by the Glasgow Prognostic Score (GPS). The complications were classified using the Common Toxicity Criteria, version 3. Anthropometric measurements such as body mass index, triceps skinfold, midarm circumference, midarm muscle area, and adductor pollicis muscle thickness were also performed, as were handgrip strength and phase angle. The chi-square test, Fisher exact test, Spearman correlation coefficient, independent t test, analysis of variance, Gabriel test, and κ index were used for the statistical analysis. P cancer (60.4 ± 14.3 y old) were included. The nutritional status according to the SGA was associated with the GPS (P nutritional assessment methods with the SGA, there were statistically significant differences. Malnutrition is highly prevalent in patients with colorectal cancer. The nutritional status was associated with the GPS. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Diagnostic performance of a rapid in-clinic test for the detection of Canine Parvovirus under different storage conditions and vaccination status.

    Science.gov (United States)

    Kantere, Maria C; Athanasiou, Labrini V; Spyrou, Vassiliki; Kyriakis, Constantinos S; Kontos, Vassilios; Chatzopoulos, Dimitrios C; Tsokana, Constantina N; Billinis, Charalambos

    2015-04-01

    Canine parvovirus (CPV) is one of the most common causes of acute haemorrhagic enteritis in young dogs, while clinical diagnosis is often indecisive. The aim of our study was to evaluate the diagnostic accuracy of an in-clinic rapid test in the detection of CPV infection in dogs. To this end, we compared the Rapid Diagnostic Kit of Canine Parvovirus, Coronavirus and Rotavirus antigen (Quicking(®)) to PCR, which is considered as the most reliable diagnostic method. A total of 78 duplicated faecal samples were collected from diarrhoeic dogs. Vaccination history within a month prior to the onset of diarrhoea was reported for 12 of the sampled dogs. The rapid diagnostic test was performed in 23 of the faecal samples directly, while the rest were placed into a sterile cotton tipped swab suitable for collection and transportation of viruses (Sigma Σ-VCM(®)) and stored at -20 °C. The sensitivity of the Quicking rapid diagnostic test compared to PCR in the total number of samples, in samples from non-vaccinated dogs and in samples tested directly after collection were 22.22% (95% CI: 13.27-33.57%), 26.67% (95% CI: 16.08-39.66%) and 76.47% (95% CI: 50.10-93.04%) respectively, while the specificity of the test was 100% in any case. In conclusion, negative results do not exclude parvoenteritis from the differential diagnosis, especially in dogs with early vaccination history, but a positive result almost certainly indicates CPV infection. An improved sensitivity may be expected when the test is performed immediately. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. The association of self-reported sleep, weight status, and academic performance in fifth-grade students.

    Science.gov (United States)

    Stroebele, Nanette; McNally, Janise; Plog, Amy; Siegfried, Scott; Hill, James O

    2013-02-01

    To improve support and justification for health promotion efforts in schools, it is helpful to understand how students' health behaviors affect academic performance. Fifth-grade students completed an online school-administered health survey with questions regarding their eating behavior, physical activity, academic performance, and sleep patterns. Differences in health behaviors were examined by sex, self-reported weight status, and sufficient (≥9 hours) versus insufficient sleep. Logistic regression was used to determine the relationship between academic performance and the health behaviors. One third of the sample did not get the recommended amount of physical activity and more than half of the students watched television ≥ 2 hours/day. Self-reported overweight status was related to lower self-reported academic performance, fewer lunch and breakfast occasions, less physical activity, not meeting the recommendations for vegetable and soda consumption as well as hours of television watching. Sufficient sleep (≥9 hours/night) was associated with better grades, meeting the recommended hours of daily television watching and video game playing, being more physically active and increased breakfast and lunch frequency. Percentage of serving free/reduced lunch, soda consumption, breakfast frequency, amount of physical activity, and television watching were associated with academic performance. More positive health behaviors generally were associated with better academic performance. Promoting healthy behaviors in schools might improve not only students' health academic performance as well. © 2013, American School Health Association.

  3. The relationship between school absence, academic performance, and asthma status.

    Science.gov (United States)

    Moonie, Sheniz; Sterling, David A; Figgs, Larry W; Castro, Mario

    2008-03-01

    Children with asthma experience more absenteeism from school compared with their nonasthma peers. Excessive absenteeism is related to lower student grades, psychological, social, and educational adjustment. Less is known about the relationship between the presence of asthma and the academic achievement in school-aged children. Since students with asthma miss more days from school, this may negatively impact their academic achievement. The goal of this study was to investigate the relationships between absenteeism, presence of asthma, and asthma severity level with standardized test level performance in a predominantly African American urban school district. A cross-sectional analysis was conducted of 3812 students (aged 8-17 years) who took the Missouri Assessment Program (MAP) standardized test during the 2002-2003 academic year. After adjustment for covariates, a significant inverse relationship was found between absenteeism and test level performance on the MAP standardized test in all children (F = 203.9, p achievement between those with and without asthma (p = .12). Though not statistically different, those with persistent asthma showed a modestly increased likelihood of scoring below Nearing Proficient compared with those with mild intermittent asthma (adjusted odds ratio = 1.93, 95% confidence intervals = 0.93-4.01, p = .08). A negative impact of absenteeism on standardized test level achievement was demonstrated in children from an urban African American school district. Children with asthma perform the same academically as their nonasthma peers. However, those with persistent asthma show a trend of performing worse on MAP standardized test scores and have more absence days compared with other students. More research is warranted on the effects of persistent asthma on academic achievement.

  4. Factors affecting the auction price of Veldram performance tested ...

    African Journals Online (AJOL)

    The popularity of these auctions for performance tested rams (89.4 % of rams sold) indicate that Veld tested rams were sought after by buyers. The sale price of 296 Veld tested Dorper rams sold between 1994 and 2001, covering seven different tests, were compared with their measured and observed performances.

  5. Fundamental motor skills, nutritional status, perceived competence, and school performance of Brazilian children in social vulnerability: Gender comparison.

    Science.gov (United States)

    Nobre, Glauber Carvalho; Valentini, Nadia Cristina; Nobre, Francisco Salviano Sales

    2018-06-01

    Being at risk or in social vulnerability situations can affect important aspects of child development. The aim of this study was to investigate fundamental motor skills (locomotor and object control) and school (writing, arithmetic, reading) performances, the perceived competence and the nutritional status of girls and boys living in social vulnerability in the poorest regions of Brazil. Two hundred eleven (211) children (87 girls, 41%), 7-10-year-old (M = 8.3, SD = 0.9), from public schools in Ceará (Brazil), living in social vulnerability, participated in the study. Children were assessed using the Test of Gross Motor Development - 2, the Body Mass Index (BMI), the Self-Perception Profile for Children, and the School Performance Test. Multivariate analysis of covariance (MANCOVA), adjusted for age, did not show any significant effect for locomotion. There was an effect of gender on the object control. Boys showed higher scores in striking, kicking, throwing, and rolling a ball. Quade's nonparametric analysis showed no difference in BMI between the genders. Most children presented healthy weight. The MANCOVA showed no effect of gender on children's scores on perceived competence on the subscales; moderate scores were found for most children. There were no gender effects on school performance; both boys and girls demonstrated inferior performance. Boys and girls in social vulnerability showed inferior performance in most motor skills, moderate perceived competence and inferior school performance. These results reveal that the appropriate development of these children is at risk and that intervention strategies should be implemented to compensate the difficulties presented. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Determination of immune status in dogs against CPV-2 by recombinant protein based latex agglutination test.

    Science.gov (United States)

    Thomas, Jobin; Singh, Mithilesh; Goswami, T K; Glora, Philma; Chakravarti, Soumendu; Chander, Vishal; Upmanyu, Vikramaditya; Verma, Suman; Sharma, Chhavi; Mahendran, K

    2017-09-01

    Canine parvoviral enteritis is a highly contagious viral illness caused by canine parvovirus-2 (CPV-2) which affects puppies of mainly 6-20 weeks of age. Vaccination is pivotal in preventing and controlling CPV-2 infection. Determination of antibody status is a critical determinant for successful vaccination. The hemagglutination inhibition (HI) test is 'gold standard' test for quantification of antibodies specific to CPV-2, although the execution of this test is not feasible under field conditions. The present study was undertaken to develop a point of care testing to determine immune status prior to CPV-2 vaccination or to detect seroconversion in immunized dogs by latex agglutination test (LAT) using recombinant antigen. Truncated portion of VP2 protein (tVP2) of CPV-2 was selected on the basis of antigenic indices, overexpressed the recombinant protein in E. coli system and was subsequently used in development of LAT. A total of 59 serum samples obtained from vaccinated (n = 54) and healthy unvaccinated (n = 5) dogs were tested. The positivity was observed in 85% (46/54) of these dogs with varying agglutination pattern. The overall sensitivity and specificity of latex agglutination test in comparison to HI test was recorded as 90% and 88% respectively with an agreement value of 90% (CI = 95%). Copyright © 2017 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  7. Beam test performance of the SKIROC2 ASIC

    CERN Document Server

    Frisson, T; Anduze, M; Augustin, J.E; Bonis, J; Boudry, V; Bourgeois, C; Brient, J.C; Callier, S; Cerutti, M; Chen, S; Cornat, R; Cornebise, P; Cuisy, D; David, J; De la Taille, C; Dulucq, F; Frotin, M; Gastaldi, F; Ghislain, P; Giraud, J; Gonnin, A; Grondin, D; Guliyev, E; Hostachy, J.Y; Jeans, D; Kamiya, Y; Kawagoe, K; Kozakai, C; Lacour, D; Lavergne, L; Lee, S.H; Magniette, F; Ono, H; Poeschl, R; Rouëné, J; Seguin-Moreau, N; Song, H.S; Sudo, Y; Thiebault, A; Tran, H; Ueno, H; Van der Kolk, N; Yoshioka, T

    2015-01-01

    Beam tests of the first layers of CALICE silicon tungsten ECAL technological prototype were performed in April and July 2012 using 1–6 GeV electron beam at DESY. This paper presents an analysis of the SKIROC2 readout ASIC performance under test beam conditions.

  8. 40 CFR 63.309 - Performance tests and procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Performance tests and procedures. 63.309 Section 63.309 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Standards for Coke Oven Batteries § 63.309 Performance tests and procedures. (a) Except as otherwise...

  9. Towards Smart Buildings Performance Testing as a Service

    DEFF Research Database (Denmark)

    Markoska, Elena; Lazarova-Molnar, Sanja

    2018-01-01

    to buildings’ energy consumption. In this paper we propose a methodology for continuous performance testing of smart buildings as a service. We discuss the automatic discovery and instantiation of performance tests, as well as usage of results for discovery of potential faults and ways to improve buldings...

  10. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    We identify one potential source of bias that influences children’s performance on standardized tests and that is predictable based on psychological theory: the time at which students take the test. Using test data for all children attending Danish public schools between school years 2009....../10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus......, as the day wears on, students become increasingly fatigued and consequently more likely to underperform on a standardized test....

  11. Status report on the 12T split coil test facility SULTAN

    International Nuclear Information System (INIS)

    Blau, B.; Aebli, E.; Jakob, B.; Pasztor, G.; Vecsey, G.; della Corte, A.; Pasotti, G.; Sacchetti, N.; Spadoni, M.

    1992-01-01

    The third phase of upgrading of the superconductor test facility SULTAN into a split coil system (SULTAN III) is in progress. SULTAN III a join project of ENEA (Italy) and PSI (Switzerland) consists of two coil packages, each containing three concentrically mounted superconducting solenoids. Together they will produce a field of nearly 12T between the two coil packages, inside a solenoid bore of 58 cm. The outermost 6T coils have NbTi conductors, whereas the inner 9T and 12T coils are made of A-15 cables. All Nb 3 Sn coils are manufactured by the react-and-wind technique. The split coil arrangement, in connection with a sophisticated sample insert containing a 50 kA superconducting transformer, will allow testing of short samples of high current carrying superconductors, e.g. for fusion applications. The sample insert was designed to allow changing the samples within a few hours without warming up the whole magnet system. This paper deals with the present status and potential of the Split Coil Test Facility SULTAN III

  12. The Quadratic Relationship between Socioeconomic Status and Learning Performance in China by Multilevel Analysis: Implications for Policies to Foster Education Equity

    Science.gov (United States)

    Zhao, Ningning; Valcke, Martin; Desoete, Annemie; Verhaeghe, JeanPierre

    2012-01-01

    The purpose of the present study is to explore the relationship between family socioeconomic status and mathematics performance on the base of a multi-level analysis involving a large sample of Chinese primary school students. A weak relationship is found between socioeconomic status and performance in the Chinese context. The relationship does…

  13. Assessing fitness-for-duty and predicting performance with cognitive neurophysiological measures

    Science.gov (United States)

    Smith, Michael E.; Gevins, Alan

    2005-05-01

    Progress is described in developing a novel test of neurocognitive status for fitness-for-duty testing. The Sustained Attention & Memory (SAM) test combines neurophysiologic (EEG) measures of brain activation with performance measures during a psychometric test of sustained attention and working memory, and then gauges changes in neurocognitive status relative to an individual"s normative baseline. In studies of the effects of common psychoactive substances that can affect job performance, including sedating antihistamines, caffeine, alcohol, marijuana, and prescription medications, test sensitivity was greater for the combined neurophysiological and performance measures than for task performance measures by themselves. The neurocognitive effects of overnight sleep deprivation were quite evident, and such effects predicted subsequent performance impairment on a flight simulator task. Sensitivity to diurnal circadian variations was also demonstrated. With further refinement and independent validation, the SAM Test may prove useful for assessing readiness-to-perform in high-asset personnel working in demanding, high risk situations.

  14. Post-test analysis for the APR1400 LBLOCA DVI performance test using MARS

    International Nuclear Information System (INIS)

    Bae, Kyoo Hwan; Lee, Y. J.; Kim, H. C.; Bae, Y. Y.; Park, J. K.; Lee, W.

    2002-03-01

    Post-test analyses using a multi-dimensional best-estimate analysis code, MARS, are performed for the APR1400 LBLOCA DVI (Direct Vessel Injection) performance tests. This report describes the code evaluation results for the test data of various void height tests and direct bypass tests that have been performed at MIDAS test facility. MIDAS is a scaled test facility of APR1400 with the objective of identifying multi-dimensional thermal-hydraulic phenomena in the downcomer during the reflood conditions of a large break LOCA. A modified linear scale ratio was applied in its construction and test conditions. The major thermal-hydraulic parameters such as ECC bypass fraction, steam condensation fraction, and temperature distributions in downcomer are compared and evaluated. The evaluation results of MARS code for the various test cases show that: (a) MARS code has an advanced modeling capability of well predicting major multi-dimensional thermal-hydraulic phenomena occurring in the downcomer, (b) MARS code under-predicts the steam condensation rates, which in turn causes to over-predict the ECC bypass rates. However, the trend of decrease in steam condensation rate and increase in ECC bypass rate in accordance with the increase in steam flow rate, and the calculation results of the ECC bypass rates under the EM analysis conditions generally agree with the test data

  15. The Effect of Sensory Room Intervention on Perceptual-Cognitive Performance and Psychiatric Status of People with Schizophrenia

    Directory of Open Access Journals (Sweden)

    Ara Shahgholi

    2012-10-01

    Full Text Available Objectives: Individuals with schizophrenia show perceptual-cognitive abnormalities. Besides, depression and anxiety is an integral part of the disease most of the times. People with mental diseases, while under institutional care, experience lack of control and choice in their daily lives. Sensory room is an environment in which individuals can choose, control and explore the stimuli around them. So, they can organize their responses to their environment and restore and develop their skills, interacting through it. Methods: 48 people met the study criteria, who were evaluated with Lowenstein Occupational Therapy Cognitive Assessment, Mini Mental State examination, and Positive and Negative Syndrome Scale. Then they were randomly and equally assigned to intervention and comparison groups. Intervention group received sensory room intervention and comparison group had their traditional therapies. After 32 treatment sessions, 14 participants in intervention group and 7 participants in comparison group were excluded from the study and the tests were repeated for the remaining ones. Results: Findings did not show a significant effect of sensory room intervention on perceptual-cognitive performance and psychiatric status of people with schizophrenia (P>0.05. In reminding domain, however, results indicated maintenance of the skill in intervention group (P>0.05. and exacerbating of that in comparison group (P<0.05. Discussion: No significant change in perceptual-cognitive performance and psychiatric status for individuals with schizophrenia during 3 month period of sensory room intervention was found, except for reminding which did not changed significantly in intervention group, but regressed in comparison group after the intervention period.

  16. Exploration of task performance tests in a physics laboratory

    Science.gov (United States)

    Liu, Dan; El Turkey, Houssein

    2017-11-01

    In this article, we investigate the implementation of task performance tests in an undergraduate physics laboratory. Two performance tests were carried out over two semesters using the task of building a DC circuit. The first implementation in Spring 2014 had certain concerns such as the privacy of students’ testing and their ‘trial and error’ attempts. These concerns were addressed in Fall 2015 through implementing a second performance test. The second implementation was administered differently but the content of the two tests was the same. We discuss the validity of both implementations and present the correlation (or lack of) between the time that students needed to complete the tests and their grades from a paper-based laboratory assessment method.

  17. The Variable and Changing Status of Performance Art Relics and Artifacts in Museum Collections

    DEFF Research Database (Denmark)

    Cone, Louise

    2017-01-01

    The status of an artwork in a museum collection is variable and contingent upon factors and parameters that are specific not only to the logic of the museum world but also to factors extrinsic to the museum. In particular older performance art 'relics' are subject to contextual interpretations...

  18. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Science.gov (United States)

    2010-07-01

    ... evaluations, and performance evaluations must I conduct? 63.2354 Section 63.2354 Protection of Environment... tests, design evaluations, and performance evaluations must I conduct? (a)(1) For each performance test... procedures specified in subpart SS of this part. (3) For each performance evaluation of a continuous emission...

  19. Model tests on dynamic performance of RC shear walls

    International Nuclear Information System (INIS)

    Nagashima, Toshio; Shibata, Akenori; Inoue, Norio; Muroi, Kazuo.

    1991-01-01

    For the inelastic dynamic response analysis of a reactor building subjected to earthquakes, it is essentially important to properly evaluate its restoring force characteristics under dynamic loading condition and its damping performance. Reinforced concrete shear walls are the main structural members of a reactor building, and dominate its seismic behavior. In order to obtain the basic information on the dynamic restoring force characteristics and damping performance of shear walls, the dynamic test using a large shaking table, static displacement control test and the pseudo-dynamic test on the models of a shear wall were conducted. In the dynamic test, four specimens were tested on a large shaking table. In the static test, four specimens were tested, and in the pseudo-dynamic test, three specimens were tested. These tests are outlined. The results of these tests were compared, placing emphasis on the restoring force characteristics and damping performance of the RC wall models. The strength was higher in the dynamic test models than in the static test models mainly due to the effect of loading rate. (K.I.)

  20. Effect of dietary iron source and iron status on iron bioavailability tests in the rat

    International Nuclear Information System (INIS)

    Zhang, D.; Hendricks, D.G.; Mahoney, A.W.

    1986-01-01

    Weanling male rats were made anemic in 7 days by feeding a low iron diet and bleeding. Healthy rats were fed the low iron diet supplemented with ferrous sulfate (29 ppm Fe). Each group was subdivided and fed for 10 days on test diets containing about 29 ppm iron that were formulated with meat:spinach mixtures or meat:soy mixtures to provided 100:0, 75:25, 50:50, 25:75, or 0:100% of the dietary iron from these sources or from a ferrous sulfate diet. After 3 days on the diets all rats were dosed orally with 2 or 5 micro curries of 59 Fe after a 18 hour fast and refeeding for 1.5 hours. Iron status influenced liver iron, carcass iron, liver radio activity and percent of radioactive dose retained. Diet influenced fecal iron and apparent absorption of iron. In iron bioavailability studies assessment methodology and iron status of the test subject greatly influences the estimates of the value of dietary sources of iron

  1. Annual Status Report (FY2016) Performance Assessment for the Environmental Restoration Disposal Facility

    Energy Technology Data Exchange (ETDEWEB)

    Casbon, M. A. [CH2M HILL Plateau Remediation Company, Richland, WA (United States); Nichols, W. E. [CH2M HILL Plateau Remediation Company, Richland, WA (United States)

    2017-03-15

    DOE O 435.1, Radioactive Waste Management, and DOE M 435.1-1, Radioactive Waste Management Manual, require that a determination of continued adequacy of the performance assessment (PA), composite analysis (CA), and disposal authorization statement (DAS) be made on an annual basis, and it must consider the results of data collection and analysis from research, field studies, and monitoring. Annual summaries of low-level waste (LLW) disposal operations must be prepared with respect to the conclusions and recommendations of the PA and CA, and a determination of the need to revise the PA or CA must be made. The annual summary requirement provides a structured approach for demonstrating the continued adequacy of the PA and CA in demonstrating a reasonable expectation that the performance objectives will be met. This annual summary addresses only the status of the Environmental Restoration Disposal Facility (ERDF) PA (CP-60089, Performance Assessment for the Environmental Restoration Disposal Facility, Hanford Site, Washington, formerly WCH-520 Rev. 1)1. The CA for ERDF is supported by DOE/RL-2016-62, Annual Status Report (FY 2016): Composite Analysis of Low Level Waste Disposal in the Central Plateau at the Hanford Site. The ERDF PA portion of the CA document is found in Section 3.1.4, and the ERDF operations portion is found in Section 3.3.3.2 of that document.

  2. Quality of life, symptom status and physical performance in patients with advanced non-small cell lung cancer undergoing chemotherapy: an exploratory analysis of secondary data.

    Science.gov (United States)

    Shallwani, Shirin M; Simmonds, Maureen J; Kasymjanova, Goulnar; Spahija, Jadranka

    2016-09-01

    Our objectives were: (a) to identify predictors of change in health-related quality of life (HRQOL) in patients with advanced non-small cell lung cancer (NSCLC) undergoing chemotherapy; and (b) to characterize symptom status, nutritional status, physical performance and HRQOL in this population and to estimate the extent to which these variables change following two cycles of chemotherapy. A secondary analysis of a longitudinal observational study of 47 patients (24 men and 23 women) with newly diagnosed advanced NSCLC receiving two cycles of first-line chemotherapy was performed. Primary outcomes were changes in HRQOL (physical and mental component summaries (PCS and MCS) of the 36-item Short-Form Health Survey (SF-36)). Predictors in the models included pre-chemotherapy patient-reported symptoms (Schwartz Cancer Fatigue Scale (SCFS) and Lung Cancer Subscale), nutritional screening (Patient-Generated Subjective Global Assessment) and physical performance measures (6-min Walk Test (6MWT), one-minute chair rise test and grip strength). Mean SF-36 PCS score, 6MWT distance and grip strength declined following two cycles of chemotherapy (pmental component of HRQOL accounting for 13% and 9% of the variance, respectively. No significant predictors were found for change in the physical component of HRQOL. Pre-chemotherapy 6MWT distance and fatigue severity predicted change in the mental component of HRQOL in patients with advanced NSCLC undergoing chemotherapy, while physical performance declined during treatment. Clinical management of these factors may be useful for HRQOL optimization in this population. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. The Jules Horowitz reactor, a new high performance European material testing reactor open to international users: present status and objectives

    International Nuclear Information System (INIS)

    Iracane, D.; Bignan, G.

    2010-01-01

    The development of nuclear power as a sustainable and competitive energy source will continue to require research and development of fuel and material behaviour under irradiation. This necessitates a high performance material testing reactor (MTR). Facing the obsolescence of most of the existing MTR in Europe, France decided a few years ago the construction of the RJH (Jules Horowitz reactor). RJH is designed, built and will be operated as an international user facility. A first set of experimental hosting devices is being designed. For instance, there are the in-core CALIPSO Nak integrated loop for material studies and other loops for fuel studies under nominal or off-normal or accidental conditions. The RJH international program will focus on the following subjects: -) fuel reliability, assessed through power ramps tests and post-irradiation examination; -) Loss of coolant tests done out-of-pile in a first phase and in-pile in a possible second phase; and -) source term tests addressing fission products release. The paper reports also the point of view of VATTENFALL (a Swedish power utility), as a potential European RJH user. (A.C.)

  4. Modified performance test of vented lead acid batteries for stationary applications

    International Nuclear Information System (INIS)

    Uhlir, K.W.; Fletcher, R.J.

    1995-01-01

    The concept of a modified performance test for vented lead acid batteries in stationary applications has been developed by the IEEE Battery Working Group. The modified performance test is defined as a test in the ''as found'' condition of the battery capacity and its ability to provide a high rate, short duration load (usually the highest rate of the duty cycle) that will confirm the battery's ability to meet the critical period of the load duty cycle, in addition to determining its percentage of rated capacity. This paper will begin by reviewing performance and service test requirements and concerns associated with both types of tests. The paper will then discuss the rationale for developing a modified performance test along with the benefits that can be derived from performing a modified performance test in lieu of a capacity test and/or a service test. The paper will conclude with an example on how to apply a modified performance test and test acceptance criteria

  5. Socioeconomic status and parenting in ethnic minority families: testing a minority family stress model.

    Science.gov (United States)

    Emmen, Rosanneke A G; Malda, Maike; Mesman, Judi; van Ijzendoorn, Marinus H; Prevoo, Mariëlle J L; Yeniad, Nihal

    2013-12-01

    According to the family stress model (Conger & Donnellan, 2007), low socioeconomic status (SES) predicts less-than-optimal parenting through family stress. Minority families generally come from lower SES backgrounds than majority families, and may experience additional stressors associated with their minority status, such as acculturation stress. The primary goal of this study was to test a minority family stress model with a general family stress pathway, as well as a pathway specific to ethnic minority families. The sample consisted of 107 Turkish-Dutch mothers and their 5- to 6-year-old children, and positive parenting was observed during a 7-min problem-solving task. In addition, mothers reported their daily hassles, psychological distress, and acculturation stress. The relation between SES and positive parenting was partially mediated by both general maternal psychological stress and maternal acculturation stress. Our study contributes to the argument that stressors specific to minority status should be considered in addition to more general demographic and family stressors in understanding parenting behavior in ethnic minority families.

  6. Performance test of solar-assisted ejector cooling system

    KAUST Repository

    Huang, Bin-Juine

    2014-03-01

    A solar-assisted ejector cooling/heating system (SACH-2k) is built and test result is reported. The solar-driven ejector cooling system (ECS) is connected in series with an inverter-type air conditioner (IAC). Several advanced technologies are developed in SACH-k2, including generator liquid level control in ECS, the ECS evaporator temperature control, and optimal control of fan power in cooling tower of ECS. From the field test results, the generator liquid level control performs quite well and keeps stable performance of ejector. The ECS evaporator temperature control also performs satisfactorily to keep ejector performance normally under low or fluctuating solar radiation. The fan power control system cooling tower performs stably and reduces the power consumption dramatically without affecting the ECS performance. The test results show that the overall system COPo including power consumptions of peripheral increases from 2.94-3.3 (IAC alone) to 4.06-4.5 (SACH-k2), about 33-43%. The highest COPo is 4.5. © 2013 Elsevier Ltd and IIR. All rights reserved.

  7. Safety test facilities - status, needs, future directions

    International Nuclear Information System (INIS)

    Heusener, G.; Cogne, F.

    1979-08-01

    A survey is given of the in-pile programs which are presently or in the near future being performed in the DeBeNe-area and in France. Only those in-pile programs are considered which are dealing with severe accidents that might lead to disruption of major parts of the core. By comparing the needs with the goals of the present programs points are identified which are not sufficiently well covered up till now. The future procedure is described: the existing facilities will be used to the largest possible extent. Whenever it is necessary, upgrading and improvement will be foreseen. Studies of a Test Facility allowing the transient testing of large pin bundles should be continued. The construction of such a facility in Europe in the near future however seems premature

  8. The Performance test of Mechanical Sodium Pump with Water Environment

    International Nuclear Information System (INIS)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Jeong, Ji-Young; Kim, Jong-Bum; Ko, Bock Seong; Park, Sang Jun; Lee, Yoon Sang

    2015-01-01

    As contrasted with PWR(Pressurized light Water Reactor) using water as a coolant, sodium is used as a coolant in SFR because of its low melting temperature, high thermal conductivity, the high boiling temperature allowing the reactors to operate at ambient pressure, and low neutron absorption cross section which is required to achieve a high neutron flux. But, sodium is violently reactive with water or oxygen like the other alkali metal. So Very strict requirements are demanded to design and fabricate of sodium experimental facilities. Furthermore, performance testing in high temperature sodium environments is more expensive and time consuming and need an extra precautions because operating and maintaining of sodium experimental facilities are very difficult. The present paper describes performance test results of mechanical sodium pump with water which has been performed with some design changes using water test facility in SAM JIN Industrial Co. To compare the hydraulic characteristic of model pump with water and sodium, the performance test of model pump were performed using vender's experimental facility for mechanical sodium pump. To accommodate non-uniform thermal expansion and to secure the operability and the safety, the gap size of some parts of original model pump was modified. Performance tests of modified mechanical sodium pump with water were successfully performed. Water is therefore often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Normal practice to thoroughly test a design or component before applied or installed in reactor is important to ensure the safety and operability in the sodium-cooled fast reactor (SFR). So, in order to estimate the hydraulic behavior of the PHTS pump of DSFR (600 MWe Demonstraion SFR), the performance tests of the model pump such as performance

  9. Academic Interventions for Elementary and Middle School Students with Low Socioeconomic Status

    DEFF Research Database (Denmark)

    Dietrichson, Jens; Bøg, Martin; Filges, Trine

    2017-01-01

    Socioeconomic status is a major predictor of educational achievement. This systematic review and meta-analysis seeks to identify effective academic interventions for elementary and middle school students with low socioeconomic status. Included studies have used a treatment-control group design......, were performed in OECD and EU countries, and measured achievement by standardized tests in mathematics or reading. The analysis included 101 studies performed during 2000-2014, 76 percent of which were randomized controlled trials. The effect sizes (ES) of many interventions indicate...

  10. Carbohydrate ingestion improves performance of a new reliable test of soccer performance.

    Science.gov (United States)

    Currell, Kevin; Conway, Steve; Jeukendrup, Asker E

    2009-02-01

    The aim of the study was to investigate the reliability of a new test of soccer performance and evaluate the effect of carbohydrate (CHO) on soccer performance. Eleven university footballers were recruited and underwent 3 trials in a randomized order. Two of the trials involved ingesting a placebo beverage, and the other, a 7.5% maltodextrin solution. The protocol comprised a series of ten 6-min exercise blocks on an outdoor Astroturf pitch, separated by the performance of 2 of the 4 soccer-specific tests, making the protocol 90 min in duration. The intensity of the exercise was designed to be similar to the typical activity pattern during soccer match play. Participants performed skill tests of dribbling, agility, heading, and shooting throughout the protocol. The coefficients of variation for dribbling, agility, heading, and shooting were 2.2%, 1.2%, 7.0%, and 2.8%, respectively. The mean combined placebo scores were 42.4 +/- 2.7 s, 43.1 +/- 3.7 s, 210 +/- 34 cm, and 212 +/- 17 points for agility, dribbling, heading, and kicking, respectively. CHO ingestion led to a combined agility time of 41.5 +/- 0.8 s, for dribbling 41.7 +/- 3.5 s, 213 +/- 11 cm for heading, and 220 +/- 5 points for kicking accuracy. There was a significant improvement in performance for dribbling, agility, and shooting (p soccer performance, and ingesting CHO leads to an improvement in soccer performance.

  11. Performance of ARCHITECT HCV core antigen test with specimens from US plasma donors and injecting drug users.

    Science.gov (United States)

    Mixson-Hayden, Tonya; Dawson, George J; Teshale, Eyasu; Le, Thao; Cheng, Kevin; Drobeniuc, Jan; Ward, John; Kamili, Saleem

    2015-05-01

    Hepatitis C virus (HCV) core antigen is a serological marker of current HCV infection. The aim of this study was mainly to evaluate the performance characteristics of the ARCHITECT HCV core antigen assay with specimens from US plasma donors and injecting drug users. A total of 551 serum and plasma samples with known anti-HCV and HCV RNA status were tested for HCV core antigen using the Abbott ARCHITECT HCV core antigen test. HCV core antigen was detectable in 100% of US plasma donor samples collected during the pre-seroconversion phase of infection (anti-HCV negative/HCV RNA positive). Overall sensitivity of the HCV core antigen assay was 88.9-94.3% in samples collected after seroconversion. The correlation between HCV core antigen and HCV RNA titers was 0.959. HCV core antigen testing may be reliably used to identify current HCV infection. Published by Elsevier B.V.

  12. Caregivers' Attitudes towards HIV Testing and Disclosure of HIV Status to At-Risk Children in Rural Uganda.

    Directory of Open Access Journals (Sweden)

    Rick Lorenz

    Full Text Available Caregivers of HIV-positive children were interviewed in the Mbarara and Isingiro districts of Uganda to identify current trends in practices related to HIV testing and the disclosure of HIV status to the child. A total of 28 caregivers of at least one HIV-positive child participated in semi-structured interviews exploring when and why they tested the child for HIV, when the child was informed of their positive status, and what the caregiver did to prepare themselves and the child for status disclosure. For a majority (96% of respondents, the decision to test the child for HIV was due to existing illness in either the child or a relative. Other common themes identified included the existence of stigma in the caregivers' communities and doubt that the children truly understood what was being explained to them when their status was disclosed. Most (65% children were informed of their HIV status between the ages of 5 and 9, with the mean age of disclosure occurring at the age of 7. General provision of HIV information typically began at the same age as disclosure, and as many as two thirds (64% of the caregivers sought advice from an HIV counsellor prior to disclosure. How a caregiver chose to prepare themselves and the child did not affect the caregiver's perception of whether the disclosure experience was beneficial or not. These findings suggest that the HIV disclosure experience in Mbarara and Isingiro districts differs from current guidelines, especially with respect to age of disclosure, how caregivers prepare themselves and the child, and approaching disclosure as an ongoing process. The doubts expressed by caregivers regarding the child's level of HIV understanding following the disclosure experience suggest the children may be insufficiently prepared at the time of the initial disclosure event. The findings also suggest that examining the content of pre-disclosure counselling and HIV education, and how health care professionals are trained

  13. DEVELOPING an ENGLISH PERFORMANCE TEST for INCOMING INDONESIAN COLLEGE STUDENTS

    Directory of Open Access Journals (Sweden)

    Bill Glenny Wullur

    2011-07-01

    Full Text Available Abstracts This study constructed, developed and validated an English Performance test as a complementary to an existing placement test in Universitas Klabat, Manado, Indonesia.  It is designed to provide a valid criterion-based measurement within the placement programs of the said university. The study aimed to answer the following questions: (1 What test tasks and items are needed in a performance test based on current language testing theory? (2 Is the performance test valid? (3 Is the scoring of the performance test reliable? (4 Is the performance test practical and predictive? And (5 What are the ratings of the resultant performance test? The steps in developing a performance test involved conducting needs analysis, establishing attributes of good performance test, and constructing test specification based on current language testing theory.  The speech event chosen which would generate language use was applying for financial assistance.  From this speech event, four activities were elicited: (1 writing a letter of inquiry, (2 completing an application form, (3 making an appointment for interview, (4 giving an oral presentation/interview.  These activities represent the four authentic tasks in which the desirable modes/channel of communication, language functions and skills, genre, and topic are integrated. The developed test is divided into four sections corresponding with the elicited tasks: (1 Formal letter, (2 Application form, (3 Making Appointment, and (4 Oral Presentation. The test was validated in several ways: (1 face validation compared the scores of Indonesian studying in the Philippines and in Indonesia, and found that the scores are highly correlated at Spearman ρ = .85.  (2 The content validation relied on the evaluation of expert informants.  The finding shows that the content coverage and relevance of the test is highly satisfactory. (3 The concurrent validation was conducted to the existing placement test and found

  14. Performance tests for integral reactor nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Dong-Seong; Yim, Jeong-Sik; Lee, Chong-Tak; Kim, Han-Soo; Koo, Yang-Hyun; Lee, Byung-Ho; Cheon, Jin-Sik; Oh, Je-Yong

    2006-02-15

    An integral type reactor SMART plans to utilize metallic Zr-U fuel which is Zr-based alloy with 34{approx}38 wt% U. In order to verify the technologies for the design and manufacturing of the fuel and get a license, performance tests were carried out. Experimental Fuel Assembly (EFA) manufactured in KAERI is being successfully irradiated in the MIR reactor of RIAR from September 4 2004, and it has achieved burnup of 0.21 g/cc as of January 25 2006. Thermal properties of irradiated Zr-U fuel were measured. Up to the phase transformation temperature, thermal diffusivity increased linearly in proportion to temperature. However its dependence on the burnup was not significant. RIA tests with 4 unirradiated Zr-U fuel rods were performed in Kurchatov Institute to establish a safety criterion. In the case of the un-irradiated Zr-U fuel, the energy deposition during the control rod ejection accident should be less than 172 cal/g to prevent the failure accompanying fuel fragmentation and dispersal. Finally the irradiation tests of fuel rods have been performed at HANARO. The HITE-2 test was successfully completed up to a burnup of 0.31 g/cc. The HITE-3 test began in February 2004 and will be continued up to a target burnup of 0.6 g/cc.

  15. Test Driven Development: Performing Art

    Science.gov (United States)

    Bache, Emily

    The art of Test Driven Development (TDD) is a skill that needs to be learnt, and which needs time and practice to master. In this workshop a select number of conference participants with considerable skill and experience are invited to perform code katas [1]. The aim is for them to demonstrate excellence and the use of Test Driven Development, and result in some high quality code. This would be for the benefit of the many programmers attending the conference, who could come along and witness high quality code being written using TDD, and get a chance to ask questions and provide feedback.

  16. Status of the AFP Project in ATLAS

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00224260; The ATLAS collaboration

    2017-01-01

    Status of the AFP project in the ATLAS experiment is given. In 2016 one arm of the AFP detector was installed and first data have been taken. In parallel with integration of the AFP subdetector into the ATLAS TDAQ nad DCS, beam tests and preparations for the installation of the 2nd arm are performed.

  17. Does performance status influence the outcome of Nd:YAG laser therapy of proximal esophageal tumors?

    NARCIS (Netherlands)

    Alexander, G. L.; Wang, K. K.; Ahlquist, D. A.; Viggiano, T. R.; Gostout, C. J.; Balm, R.

    1994-01-01

    The value of endoscopic palliative therapy for malignant obstruction in the proximal esophagus has been questioned. To assess the importance of pre-treatment performance status on treatment outcome, we reviewed the records of patients with tumors of the proximal esophagus undergoing endoscopic laser

  18. Development of a grinding-specific performance test set-up.

    Science.gov (United States)

    Olesen, C G; Larsen, B H; Andresen, E L; de Zee, M

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding performance.

  19. Reliability performance testing of totally encapsulating chemical protective suits

    International Nuclear Information System (INIS)

    Johnson, J.S.; Swearengen, P.M.

    1991-01-01

    The need to assure a high degree of reliability for totally encapsulating chemical protective (TECP) suits has been recognized by Lawrence Livermore National Laboratory's (LLNL) Hazards Control Department for some time. The following four tests were proposed as necessary to provide complete evaluation of TECP suit performance: 1. Quantitative leak test (ASTM draft), 2. Worst-case chemical exposure test (conceptual), 3. Pressure leak-rate test (complete, ASTM F1057-87), and 4. Chemical leak-rate test (ASTM draft). This paper reports on these tests which should be applied to measuring TECP suit performance in two stages: design qualification tests and field use tests. Test 1, 2, and 3 are used as design qualification tests, and tests 3 and 4 are used as field use tests

  20. Performance demonstration tests for eddy current inspection of steam generator tubing

    International Nuclear Information System (INIS)

    Kurtz, R.J.; Heasler, P.G.; Anderson, C.M.

    1996-05-01

    This report describes the methodology and results for development of performance demonstration tests for eddy current (ET) inspection of steam generator tubes. Statistical test design principles were used to develop the performance demonstration tests. Thresholds on ET system inspection performance were selected to ensure that field inspection systems would have a high probability of detecting and and correctly sizing tube degradation. The technical basis for the ET system performance thresholds is presented in detail. Statistical test design calculations for probability of detection and flaw sizing tests are described. A recommended performance demonstration test based on the design calculations is presented. A computer program for grading the probability of detection portion of the performance demonstration test is given

  1. Performance demonstration tests for eddy current inspection of steam generator tubing

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, R.J.; Heasler, P.G.; Anderson, C.M.

    1996-05-01

    This report describes the methodology and results for development of performance demonstration tests for eddy current (ET) inspection of steam generator tubes. Statistical test design principles were used to develop the performance demonstration tests. Thresholds on ET system inspection performance were selected to ensure that field inspection systems would have a high probability of detecting and and correctly sizing tube degradation. The technical basis for the ET system performance thresholds is presented in detail. Statistical test design calculations for probability of detection and flaw sizing tests are described. A recommended performance demonstration test based on the design calculations is presented. A computer program for grading the probability of detection portion of the performance demonstration test is given.

  2. Test anxiety and academic performance in chiropractic students.

    Science.gov (United States)

    Zhang, Niu; Henderson, Charles N R

    2014-01-01

    Objective : We assessed the level of students' test anxiety, and the relationship between test anxiety and academic performance. Methods : We recruited 166 third-quarter students. The Test Anxiety Inventory (TAI) was administered to all participants. Total scores from written examinations and objective structured clinical examinations (OSCEs) were used as response variables. Results : Multiple regression analysis shows that there was a modest, but statistically significant negative correlation between TAI scores and written exam scores, but not OSCE scores. Worry and emotionality were the best predictive models for written exam scores. Mean total anxiety and emotionality scores for females were significantly higher than those for males, but not worry scores. Conclusion : Moderate-to-high test anxiety was observed in 85% of the chiropractic students examined. However, total test anxiety, as measured by the TAI score, was a very weak predictive model for written exam performance. Multiple regression analysis demonstrated that replacing total anxiety (TAI) with worry and emotionality (TAI subscales) produces a much more effective predictive model of written exam performance. Sex, age, highest current academic degree, and ethnicity contributed little additional predictive power in either regression model. Moreover, TAI scores were not found to be statistically significant predictors of physical exam skill performance, as measured by OSCEs.

  3. Drop Performance Test of CRDMs for JRTR

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Myoung-Hwan; Cho, Yeong-Garp; Chung, Jong-Ha [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Jung-Hyun [POSCO Plandtec Co. Ltd, Ulsan (Korea, Republic of); Lee, Kwan-Hee [RIST, Pohang (Korea, Republic of)

    2015-10-15

    The drop test results of CRDMs with AC-type electromagnet show that the initial delay times are not satisfied with the requirement, 0.15 seconds. After the replacement of the electromagnet from AC-type to DCtype, the drop times of CARs and accelerations due to the impact of moving parts are satisfied with all requirements. As a result, it is found that four CRDMs to be installed at site have a good drop performance, and meet all performance requirements. A control rod drive mechanism (CRDM) is a device to control the position of a control absorber rod (CAR) in the core by using a stepping motor which is commanded by the reactor regulating system (RRS) to control the reactivity during the normal operation of the reactor. The top-mounted CRDM driven by the stepping motor for Jordan Research and Training Reactor (JRTR) has been developed in KAERI. The CRDM for JRTR has been optimized by the design improvement based on that of the HANARO. It is necessary to verify the performances such as the stepping, drop, endurance, vibration, seismic and structural integrity for active components. Especially, the CAR drop curves are important data for the safety analysis. This paper describes the test results to demonstrate the drop performances of a prototype and 4 CRDMs to be installed at site. The tests are carried out at a test rig simulating the actual reactor's conditions.

  4. Deceiving Yourself to Better Deceive High-Status Compared to Equal-Status Others

    Directory of Open Access Journals (Sweden)

    Hui Jing Lu

    2014-07-01

    Full Text Available The arms race between deception and detection is likely to have played out between individuals in different status hierarchies, with low-status individuals more likely to be deceivers and high-status individuals more likely to be detectors than the other way around. Memory and its distortion may be temporarily employed first to keep truthful information away from both self and others and later to retrieve accurate information to benefit the self. Using a dual-retrieval paradigm, we tested the hypothesis that people are likely to deceive themselves to better deceive high- rather than equal-status others. College student participants were explicitly instructed (Study 1 and 2 or induced (Study 3 to deceive either a high-status teacher or an equal-status fellow student. When interacting with the high- but not equal-status target, participants in three studies genuinely remembered fewer previously studied items than they did on a second memory test alone without the deceiving target. The results support the view that self-deception responds to status hierarchy that registers probabilities of deception detection such that people are more likely to self-deceive high- rather than equal-status others.

  5. Concordance of Barthel Index, ECOG-PS, and Palliative Performance Scale in the assessment of functional status in patients with advanced medical diseases.

    Science.gov (United States)

    Hernández-Quiles, C; Bernabeu-Wittel, M; Pérez-Belmonte, L M; Macías-Mir, P; Camacho-González, D; Massa, B; Maiz-Jiménez, M; Ollero-Baturone, M

    2017-09-01

    Analysing most relevant clinical features and concordance between different functional scales in patients with advanced medical diseases (PAMD). Cross-sectional multicentre study that included PAMD (heart, lung, kidney, liver, and neurological diseases) in hospital settings from February 2009 to October 2010. We analysed clinical, biological and functional features in performing activities of daily living (ADL) by medians of Barthel Index (BI); additionally we assessed their performance status by medians of Eastern Cooperative Oncology Group-Performance Status (ECOG-PS) and Palliative Performance Scale (PPS) scores. We evaluated the concordance of these instruments in assessing functional impairment by κ and intraclass correlation coefficient tests. 1847 patients were included (average age 79 years, 50.1% men). Most common symptoms were dyspnoea (62.31%), asthenia (23%) and delirium (20.14%). Functional assessment showed a high prevalence of severe or total impairment in performing basic ADL by medians of used instruments (BI median=35 (IQR=70), and 52.1% of patients with severe-total impairment; ECOG-PS median=2 (IQR 30), and 44% of patients with severe-total impairment; and PPS median=50 (IQR 30), and 32% of patients with severe-total impairment). Concordance among these instruments was acceptably good ( κ indexes ranging from 0.653 to 0.745 (pmanagement. Assessment of functional ability in this population by BI, ECOG-PS, and PPS showed good concordance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. New test methods for BIPV. Results from IP performance

    International Nuclear Information System (INIS)

    Jol, J.C.; Van Kampen, B.J.M.; De Boer, B.J.; Reil, F.; Geyer, D.

    2009-11-01

    Within the Performance project new test procedures for PV building products and the building performance as a whole when PV is applied in buildings have been drafted. It has resulted in a first draft of new test procedures for PV building products and proposals for tests for novel BIPV technology like thin film. The test proposed are a module breakage test for BIPV products, a fire safety test for BIPV products and a dynamic load test for BIPV products. Furthermore first proposals of how flexible PV modules could be tested in an appropriate way to ensure long time quality and safety of these new products are presented.

  7. Corrosion performance tests for reinforcing steel in concrete : test procedures.

    Science.gov (United States)

    2009-09-01

    The existing test method to assess the corrosion performance of reinforcing steel embedded in concrete, mainly : ASTM G109, is labor intensive, time consuming, slow to provide comparative results, and often expensive. : However, corrosion of reinforc...

  8. Race and vitamin D status and monitoring in male veterans.

    Science.gov (United States)

    Peiris, Alan N; Bailey, Beth A; Peiris, Prith; Copeland, Rebecca J; Manning, Todd

    2011-06-01

    African Americans have lower vitamin D levels and reduced health outcomes compared to white Americans. Vitamin D deficiency may contribute to adverse health outcomes in African Americans. We hypothesized that race would be associated with vitamin D status and testing in African Americans veterans, and that vitamin D status is a major contributor to health care costs in African American veterans compared to white veterans. A retrospective analysis of the medical data in the Veterans Integrated Service Network 9 (southeastern United States) was performed, and 14148 male veterans were identified. Race was designated by the patient and its relationship to vitamin D levels/status and costs was assessed. Vitamin D levels were significantly lower and the percent of patients with vitamin D deficiency was significantly higher in African American veterans. This difference was independent of latitude and seasonality. Vitamin D testing was done significantly more in white veterans compared to African American veterans (5.4% vs 3.8%). While follow-up testing was 42% more likely if a patient was found to be vitamin D deficient, white veterans were 34% more likely than African American veterans to have at least 1 follow-up 25-hydroxyvitamin D performed. African American veterans had significantly higher health care costs, which were linked to lower vitamin D levels; however, the cost differential persisted even after adjusting for vitamin D status. Vitamin D deficiency is highly prevalent in African American veterans and needs improved management within the Veteran Administration system. Vitamin D status appears not to be the sole contributor to increased health care costs in African American veterans.

  9. From Social Class to Self-Efficacy: Internalization of Low Social Status Pupils' School Performance

    Science.gov (United States)

    Wiederkehr, Virginie; Darnon, Céline; Chazal, Sébastien; Guimond, Serge; Martinot, Delphine

    2015-01-01

    Previous research has largely documented that socioeconomic status (SES) is a strong and consistent predictor of pupils' school performance in several countries. In this research, we argue that children internalize the SES achievement gap in the form of a lower/higher sense of school self-efficacy. In two studies, teenaged students' (Study 1) and…

  10. Impact of Educational Level on Performance on Auditory Processing Tests.

    Science.gov (United States)

    Murphy, Cristina F B; Rabelo, Camila M; Silagi, Marcela L; Mansur, Letícia L; Schochat, Eliane

    2016-01-01

    Research has demonstrated that a higher level of education is associated with better performance on cognitive tests among middle-aged and elderly people. However, the effects of education on auditory processing skills have not yet been evaluated. Previous demonstrations of sensory-cognitive interactions in the aging process indicate the potential importance of this topic. Therefore, the primary purpose of this study was to investigate the performance of middle-aged and elderly people with different levels of formal education on auditory processing tests. A total of 177 adults with no evidence of cognitive, psychological or neurological conditions took part in the research. The participants completed a series of auditory assessments, including dichotic digit, frequency pattern and speech-in-noise tests. A working memory test was also performed to investigate the extent to which auditory processing and cognitive performance were associated. The results demonstrated positive but weak correlations between years of schooling and performance on all of the tests applied. The factor "years of schooling" was also one of the best predictors of frequency pattern and speech-in-noise test performance. Additionally, performance on the working memory, frequency pattern and dichotic digit tests was also correlated, suggesting that the influence of educational level on auditory processing performance might be associated with the cognitive demand of the auditory processing tests rather than auditory sensory aspects itself. Longitudinal research is required to investigate the causal relationship between educational level and auditory processing skills.

  11. MFTF test coil construction and performance

    International Nuclear Information System (INIS)

    Cornish, D.N.; Zbasnik, J.P.; Leber, R.L.; Hirzel, D.G.; Johnston, J.E.; Rosdahl, A.R.

    1978-01-01

    A solenoid coil, 105 cm inside the 167 cm outside diameter, has been constructed and tested to study the performance of the stabilized Nb--Ti conductor to be used in the Mirror Fusion Test Facility (MFTF) being built at Lawrence Livermore Laboratory. The insulation system of the test coil is identical to that envisioned for MFTF. Cold-weld joints were made in the conductor at the start and finish of each layer; heaters were fitted to some of these joints and also to the conductor at various locations in the winding. This paper gives details of the construction of the coil and the results of the tests carried out to determine its propagation and recovery characteristics

  12. Status of the Warm Front End of PIP-II Injector Test

    Energy Technology Data Exchange (ETDEWEB)

    Shemyakin, Alexander [Fermilab; Alvarez, Matthew [Fermilab; Andrews, Richard [Fermilab; Baffes, Curtis [Fermilab; Carneiro, Jean-Paul [Fermilab; Chen, Alex [Fermilab; Derwent, Paul [Fermilab; Edelen, Jonathan [Fermilab; Frolov, Daniil [Fermilab; Hanna, Bruce [Fermilab; Prost, Lionel [Fermilab; Saewert, Gregory [Fermilab; Saini, Arun [Fermilab; Scarpine, Victor [Fermilab; Sista, V. Lalitha [Fermilab; Steimel, Jim [Fermilab; Sun, Ding [Fermilab; Warner, Arden [Fermilab

    2017-05-01

    The Proton Improvement Plan II (PIP-II) at Fermilab is a program of upgrades to the injection complex. At its core is the design and construction of a CW-compatible, pulsed H⁻ SRF linac. To validate the concept of the front-end of such machine, a test accelerator known as PIP-II Injector Test is under construction. It includes a 10 mA DC, 30 keV H⁻ ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1 MeV CW RFQ, followed by a Medium Energy Beam Transport (MEBT) that feeds the first of 2 cryomodules increasing the beam energy to about 25 MeV, and a High Energy Beam Transport section (HEBT) that takes the beam to a dump. The ion source, LEBT, RFQ, and initial version of the MEBT have been built, installed, and commissioned. This report presents the overall status of the warm front end.

  13. Influence of socioeconomic status on trauma center performance evaluations in a Canadian trauma system.

    Science.gov (United States)

    Moore, Lynne; Turgeon, Alexis F; Sirois, Marie-Josée; Murat, Valérie; Lavoie, André

    2011-09-01

    Trauma center performance evaluations generally include adjustment for injury severity, age, and comorbidity. However, disparities across trauma centers may be due to other differences in source populations that are not accounted for, such as socioeconomic status (SES). We aimed to evaluate whether SES influences trauma center performance evaluations in an inclusive trauma system with universal access to health care. The study was based on data collected between 1999 and 2006 in a Canadian trauma system. Patient SES was quantified using an ecologic index of social and material deprivation. Performance evaluations were based on mortality adjusted using the Trauma Risk Adjustment Model. Agreement between performance results with and without additional adjustment for SES was evaluated with correlation coefficients. The study sample comprised a total of 71,784 patients from 48 trauma centers, including 3,828 deaths within 30 days (4.5%) and 5,549 deaths within 6 months (7.7%). The proportion of patients in the highest quintile of social and material deprivation varied from 3% to 43% and from 11% to 90% across hospitals, respectively. The correlation between performance results with or without adjustment for SES was almost perfect (r = 0.997; 95% CI 0.995-0.998) and the same hospital outliers were identified. We observed an important variation in SES across trauma centers but no change in risk-adjusted mortality estimates when SES was added to adjustment models. Results suggest that after adjustment for injury severity, age, comorbidity, and transfer status, disparities in SES across trauma center source populations do not influence trauma center performance evaluations in a system offering universal health coverage. Copyright © 2011 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Performance testing of high specific activity waste forms per 10 CFR Part 61

    International Nuclear Information System (INIS)

    Neilson, R.M. Jr.; McConnell, J.W. Jr.; Rogers, R.D.

    1987-03-01

    The Low-Level Waste Data Base Development - EPICOR-II Resin/Liner Investigation Program of the US Nuclear Regulatory Commission (NRC) is obtaining information on radioactive waste by means of NRC-prescribed tests in a disposal environment. This paper describes the resin solidification task of that program and includes the current test status and results. 28 refs., 5 figs., 6 tabs

  15. Performance testing of personnel extremity dosimeters by Korean LiF: Mg, Cu, Na, Si TLD(KLT-300)

    International Nuclear Information System (INIS)

    Kim, J.L.; Lee, J.I.; Chang, S.Y.; Choi, H.S.; Lee, D.H.; Han, S.J.

    2005-01-01

    Full text: As the needs and opportunities for utilization of atomic energy and radiation are increasing, the related industries, medicines, environments are developing and the relevant organizations and companies are also becoming diverse. In result, the types and kinds of the radiation related to occupational environments are becoming diversified. For the whole body dosimeters, the methodology and criteria for the performance evaluation and safety regulations and laws have been prepared in some detail, but for the extremity dosimeters, those are not prepared yet in Korea. The extremity dosimeters are required when the extremity part of our body, such as hand, elbow, and arm below the elbow, the foot, knee, and leg below the knee are exposed to the radiation in specific work environments. The dosimeter irradiation conditions are clearly discriminated between the whole body exposure condition and the extremity exposure condition. By the investigation and analysis of the management status and dose evaluation methods of the extremity dosimeters for the local absorbed dose, the personnel monitoring system of the extremity dosimeter services in Korea can be diagnosed, and the performance testing criteria and procedures can be established. Therefore, this study presents the performance testing results of extremity dosimeters on the finger and arm/leg phantoms by the procedures recommended in the ANSI (American National Standard) N13.32 using KLT-300 TL materials (LiF:Mg,Cu,Nas,Si) which were developed in Korea Atomic Energy Research Institute (KAERI). The results show that the performance index for the two types of phantoms are sufficiently satisfied with the prescribed tolerance level in the all of the test categories listed in the ANSI N13.32. These results and procedures used in this study can be applicable for regulatory body to establish the standard criteria for acceptable performance and testing conditions for personnel extremity dosimeters services in the

  16. 40 CFR 60.2155 - May I conduct performance testing less often?

    Science.gov (United States)

    2010-07-01

    ... performance test. (c) If a performance test shows a deviation from an emission limitation for particulate... 40 Protection of Environment 6 2010-07-01 2010-07-01 false May I conduct performance testing less... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for...

  17. Performance testing SPECT systems: Recent developments

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.

    1985-01-01

    A protocol is used to test as many currently available systems as possible, including both rotating gamma camera systems from GE, Siemens, Toshiba, Technicare, Elscint, Philips, Picker, etc, and single/multi slice system such as the Medimatic. This paper indicates changes that have occurred with respect to preliminary results previously published. Reconstructions were performed in a standard manner, using a Ramp filter and without attenuation correction, in order to reduce the effect of differences in software. The Jaszczak phantom was used to assess overall image quality. Tests were performed using the different collimators available. Image quality improved with better spatial resolution, even at the expense of sensitivity. Non-circular orbits, where available, were tested, and resolution was comparing for various positions and directions. With double headed systems, the results obtained were compared to those using a single head alone. Some gain in image quality seems to have been achieved by better uniformity resulting from improved correction circuitry, by the use of non-circular orbits, and from scatter correction. Potential still exists to improve collimator design

  18. Status on the construction of the fuel irradiation test facility

    International Nuclear Information System (INIS)

    Park, Kook Nam; Sim, Bong Shick; Lee, Chung Young; Yoo, Seong Yeon

    2005-01-01

    As a facility to examine general performance of nuclear fuel under irradiation condition in HANARO, Fuel Test Loop(FTL) has been developed which can accommodate 3 fuel pins at the core irradiation hole(IR1 hole) taking consideration user's test requirement. 3-Pin FTL consists of In-Pile Test Section (IPS) and Out-of- Pile System (OPS). Test condition in IPS such as pressure, temperature and the water quality, can be controlled by OPS. 3-Pin FTL Conceptual design was set up in 2001 and had completed detail design including a design requirement and basic Piping and Instrument Diagram (P and ID) in 2004. The safety analysis report was prepared and submitted in early 2005 to the regulatory body(KINS) for review and approval of FTL. In 2005, the development team is going to purchase and manufacture hardware and make a contract for construction work. In 2006, the development team is going to install an FTL system performance test shall be done as a part of commissioning. After a 3-Pin FTL development which is expected to be finished by the 2007, FTL will be used for the irradiation test of the new PWR-type fuel and the usage of HANARO will be enhanced

  19. Individual differences in infant fearfulness and cognitive performance: a testing, performance, or competence effect?

    Science.gov (United States)

    Rieser-Danner, Loretta A

    2003-02-01

    The author conducted 2 studies to examine the relations between infant fear and cognitive testing performance in 12-month-old infants. In Study 1, fear was assessed by using 2 standard temperament questionnaires and a laboratory-based, standardized stranger approach. Individual differences in cognitive development were assessed using the Object Permanence Scale of the Infant Psychological Development Scales (I. C. Uzgiris & J. M. Hunt, 1975). All 3 assessments of fear significantly predicted object permanence performance, with correlations ranging from -.32 to -.35. In Study 2, fear was assessed via a maternal report questionnaire, and habituation performance was assessed via a basic-level categorization task. Familiarity with the examiner and with the testing environment was manipulated to test for a familiarity influence on performance. Testing revealed individual differences in both fear and habituation. Results suggest that highly fearful infants required more trials to habituate and were less likely to meet the habituation criterion than infants who were less fearful. Methodological and conceptual implications of these results are discussed.

  20. HIV testing and clinical status upon admission to a specialized health care unit in Pará, Brazil

    Directory of Open Access Journals (Sweden)

    Paulo Afonso Martins Abati

    2015-01-01

    Full Text Available OBJECTIVE To analyze the clinical and laboratory characteristics of HIV-infected individuals upon admission to a reference health care center. METHODS This cross-sectional study was conducted between 1999 and 2010 on 527 individuals with confirmed serological diagnosis of HIV infection who were enrolled in an outpatient health care service in Santarém, PA, Northern Brazil. Data were collected from medical records and included the reason for HIV testing, clinical status, and count of peripheral CD4+ T lymphocytes upon enrollment. The data were divided into three groups, according to the patient’s year of admission – P1 (1999-2002, P2 (2003-2006, and P3 (2007-2010 – for comparative analysis of the variables of interest. RESULTS In the study group, 62.0% of the patients were assigned to the P3 group. The reason for undergoing HIV testing differed between genders. In the male population, most tests were conducted because of the presence of symptoms suggesting infection. Among women, tests were the result of knowledge of the partner’s seropositive status in groups P1 and P2. Higher proportion of women undergoing testing because of symptoms of HIV/AIDS infection abolished the difference between genders in the most recent period. A higher percentage of patients enrolling at a more advanced stage of the disease was observed in P3. CONCLUSIONS Despite the increased awareness of the number of HIV/AIDS cases, these patients have identified their serological status late and were admitted to health care units with active disease. The HIV/AIDS epidemic in Pará presents specificities in its progression that indicate the complex characteristics of the epidemic in the Northern region of Brazil and across the country.

  1. HIV testing and clinical status upon admission to a specialized health care unit in Pará, Brazil.

    Science.gov (United States)

    Abati, Paulo Afonso Martins; Segurado, Aluisio Cotrim

    2015-01-01

    OBJECTIVE To analyze the clinical and laboratory characteristics of HIV-infected individuals upon admission to a reference health care center. METHODS This cross-sectional study was conducted between 1999 and 2010 on 527 individuals with confirmed serological diagnosis of HIV infection who were enrolled in an outpatient health care service in Santarém, PA, Northern Brazil. Data were collected from medical records and included the reason for HIV testing, clinical status, and count of peripheral CD4+ T lymphocytes upon enrollment. The data were divided into three groups, according to the patient's year of admission - P1 (1999-2002), P2 (2003-2006), and P3 (2007-2010) - for comparative analysis of the variables of interest. RESULTS In the study group, 62.0% of the patients were assigned to the P3 group. The reason for undergoing HIV testing differed between genders. In the male population, most tests were conducted because of the presence of symptoms suggesting infection. Among women, tests were the result of knowledge of the partner's seropositive status in groups P1 and P2. Higher proportion of women undergoing testing because of symptoms of HIV/AIDS infection abolished the difference between genders in the most recent period. A higher percentage of patients enrolling at a more advanced stage of the disease was observed in P3. CONCLUSIONS Despite the increased awareness of the number of HIV/AIDS cases, these patients have identified their serological status late and were admitted to health care units with active disease. The HIV/AIDS epidemic in Pará presents specificities in its progression that indicate the complex characteristics of the epidemic in the Northern region of Brazil and across the country.

  2. Diet-induced changes in iron and n-3 fatty acid status and associations with cognitive performance in 8-11-year-old Danish children: secondary analyses of the Optimal Well-Being, Development and Health for Danish Children through a Healthy New Nordic Diet School Meal Study.

    Science.gov (United States)

    Sørensen, Louise Bergmann; Damsgaard, Camilla Trab; Dalskov, Stine-Mathilde; Petersen, Rikke Agnete; Egelund, Niels; Dyssegaard, Camilla Brørup; Stark, Ken D; Andersen, Rikke; Tetens, Inge; Astrup, Arne; Michaelsen, Kim Fleisher; Lauritzen, Lotte

    2015-11-28

    Fe and n-3 long-chain PUFA (n-3 LCPUFA) have both been associated with cognition, but evidence remains inconclusive in well-nourished school-aged children. In the Optimal Well-Being, Development and Health for Danish Children through a Healthy New Nordic Diet (OPUS) School Meal Study, the 3-month intervention increased reading performance, inattention, impulsivity and dietary intake of fish and Fe. This study investigated whether the intervention influenced n-3 LCPUFA and Fe status and, if so, explored how these changes correlated with the changes in cognitive performance. The study was a cluster-randomised cross-over trial comparing school meals with packed lunch (control). At baseline and after each treatment, we measured serum ferritin, whole-blood n-3 LCPUFA and Hb, and performance in reading, mathematics and d2-test of attention. Data were analysed using mixed models (n 726) and principal component analysis of test performances (n 644), which showed two main patterns: 'school performance' and 'reading comprehension'. The latter indicated that children with good reading comprehension were also more inattentive and impulsive (i.e. higher d2-test error%). The intervention improved 'school performance' (P=0·015), 'reading comprehension' (P=0·043) and EPA+DHA status 0·21 (95% CI 0·15, 0·27) w/w % (Pschool performance' in girls, but with better 'reading comprehension' in both boys and girls. Both baseline EPA+DHA status and the intervention-induced increase in EPA+DHA status was positively associated with 'school performance', suggesting that n-3 LCPUFA could potentially explain approximately 20 % of the intervention effect. These exploratory associations indicate that increased fish intake might explain some of the increase in reading performance and inattention in the study.

  3. DPM PERFORMANCE TESTING USING RASPBERRY PIS

    CERN Document Server

    Regala, M

    2013-01-01

    This is the final report from attending CERN’s Summer Student Programme. The project goal was to do performance testing on the Disk Pool Manager (DPM), a lightweight, reliable, grid-aware storage software used to store and retrieve data produced by CERN’s LHC experiments using the small, low-end ARM powered devices named Raspberry Pis. The idea behind it was to reason if it’s possible to use a cluster of lower-end, under-capable devices to run DPM, and to conclude if it would be more energy efficient than running it on oversized machines, with the same or comparable performance. If this hypothesis was true, the power-hungry machines could be ditched in favour of these small devices, leading to an enormous saving in overall power consumption and hence, overall cost. In this report, I describe what was the initial project goal and intended outcomes, proceeding to explain the underlying technologies used. Afterwards, I’ll explain the setup used, the tests performed, and the conclusions reached. iii

  4. Test objects for evaluating the performance of radiological imaging systems. Leeds radiological test objects

    International Nuclear Information System (INIS)

    Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.

    1985-01-01

    A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)

  5. Pharmacists performing quality spirometry testing: an evidence based review.

    Science.gov (United States)

    Cawley, Michael J; Warning, William J

    2015-10-01

    The scope of pharmacist services for patients with pulmonary disease has primarily focused on drug related outcomes; however pharmacists have the ability to broaden the scope of clinical services by performing diagnostic testing including quality spirometry testing. Studies have demonstrated that pharmacists can perform quality spirometry testing based upon international guidelines. The primary aim of this review was to assess the published evidence of pharmacists performing quality spirometry testing based upon American Thoracic Society/European Respiratory Society (ATS/ERS) guidelines. In order to accomplish this, the description of evidence and type of outcome from these services were reviewed. A literature search was conducted using five databases [PubMed (1946-January 2015), International Pharmaceutical Abstracts (1970 to January 2015), Cumulative Index of Nursing and Allied Health Literature, Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews] with search terms including pharmacy, spirometry, pulmonary function, asthma or COPD was conducted. Searches were limited to publications in English and reported in humans. In addition, Uniform Resource Locators and Google Scholar searches were implemented to include any additional supplemental information. Eight studies (six prospective multi-center trials, two retrospective single center studies) were included. Pharmacists in all studies received specialized training in performing spirometry testing. Of the eight studies meeting inclusion and exclusion criteria, 8 (100%) demonstrated acceptable repeatability of spirometry testing based upon standards set by the ATS/ERS guidelines. Acceptable repeatability of seven studies ranged from 70 to 99% consistent with published data. Available evidence suggests that quality spirometry testing can be performed by pharmacists. More prospective studies are needed to add to the current evidence of quality spirometry testing performed by

  6. Play for Performance: Using Computer Games to Improve Motivation and Test-Taking Performance

    Science.gov (United States)

    Dennis, Alan R.; Bhagwatwar, Akshay; Minas, Randall K.

    2013-01-01

    The importance of testing, especially certification and high-stakes testing, has increased substantially over the past decade. Building on the "serious gaming" literature and the psychology "priming" literature, we developed a computer game designed to improve test-taking performance using psychological priming. The game primed…

  7. The National Ignition Facility 2007 laser performance status

    Energy Technology Data Exchange (ETDEWEB)

    Haynam, C A; Sacks, R A; Wegner, P J; Bowers, M W; Dixit, S N; Erbert, G V; Heestand, G M; Henesian, M A; Hermann, M R; Jancaitis, K S; Manes, K R; Marshall, C D; Mehta, N C; Menapace, J; Nostrand, M C; Orth, C D; Shaw, M J; Sutton, S B; Williams, W H; Widmayer, C C [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA, 94550 (United States)], E-mail: haynam1@llnl.gov (and others)

    2008-05-15

    The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory contains a 192-beam 3.6 MJ neodymium glass laser that is frequency converted to 351nm light. It has been designed to support high energy density science (HEDS), including the demonstration of fusion ignition through Inertial Confinement. To meet this goal, laser design criteria include the ability to generate pulses of up to 1.8-MJ total energy at 351nm, with peak power of 500 TW and precisely-controlled temporal pulse shapes spanning two orders of magnitude. The focal spot fluence distribution of these pulses is conditioned, through a combination of special optics in the 1{omega} (1053 nm) portion of the laser (continuous phase plates), smoothing by spectral dispersion (SSD), and the overlapping of multiple beams with orthogonal polarization (polarization smoothing). In 2006 and 2007, a series of measurements were performed on the NIF laser, at both 1{omega} and 3{omega} (351 nm). When scaled to full 192-beam operation, these results lend confidence to the claim that NIF will meet its laser performance design criteria and that it will be able to simultaneously deliver the temporal pulse shaping, focal spot conditioning, peak power, shot-to-shot reproducibility, and power balance requirements of indirect-drive fusion ignition campaigns. We discuss the plans and status of NIF's commissioning, and the nature and results of these measurement campaigns.

  8. The status of GALLEX

    Energy Technology Data Exchange (ETDEWEB)

    Kirsten, T.; Anselmann, P.; Breitenbach, M.; Hampel, W.; Heusser, G.; Kiko, J.; Kirsten, T.; Lenzing, A.; Pernicka, E.; Plaga, R.; Povh, B.; Schlosser, C.; Voelk, H.; Wink, R.; Wojcik, M. (Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany, F.R.)); Bellotti, E. (Laboratori Nazionali del Gran Sasso (Italy)); Ammon, R. v.; Balata, M.; Ebert, K.; Fritsch, T.; Hellriegel, K.; Henrich, E.; Stieglitz, L.; Weyrich, F. (Kernforschungszentrum Karlsruhe GmbH (Germany, F.R.)); Cremonesi, O.; Fiorini, E.; Ragazzi, S.; Zanotti, L. (Milan Univ. (Italy). Dipt. di Fisica); Feilitzsch, F. v.; Moessbauer, R.; Schanda, U. (Technische Univ. Muenchen, Garching (Germany, F.R.). Fakultaet fuer Physik); Berthomieu, G.; Schatzmann, E. (Nice Univ., 06 (France). Observatoire); Carmi, I.; Dostrovsky, I. (Weizmann Inst. of Science, Rehovoth (Israel)); D' Angelo, S.; Bacci, C.; Belli, P.; Bernabei, R.; Paoluzi, L. (Rome-2 Univ. (Italy)); Cribier, M.; Dupont, G.; Gosset, L.; Pichard, B.; Rich, J.; Spiro; GALLEX Collaboration

    1991-04-01

    A radiochemical Gallium-Solar-Neutrino Detector has been set up at the Gran Sasso Underground Laboratory. All major installations are implemented and the target, 53,5 m{sup 3} of galliumchloride solution containing 30.3 tons of gallium, has been brought underground after removing cosmogenic Ge-isotopes through nitrogen purge. This final implementation status and the achieved parameters characterizing the experiment are described in this report. Full scale performance tests and optimalization of the operating conditions of the extraction system are presently under way. (orig.).

  9. The status of performance demonstration in Taiwan

    International Nuclear Information System (INIS)

    Shyu, H.F.; Shong, W.J.

    2004-01-01

    The nuclear authority in Taiwan adopts the ASME Code Section XI, Appendix VIII as a mandatory requirement for the in-service inspection of importance nuclear components. To fulfill this requirement, the ultrasonic testing (UT) Level II of nuclear power plants have to go abroad for the qualification of performance demonstration (PD) hosted by the EPRI, USA. It is time consuming and costs much money. In order to set up domestic PD capability, this project planned and purchased test pieces, prepared qualification procedures and arranged examination site. A prototype PD system for carbon steel piping weld and stainless steel piping weld manual UT has been established from 2002. Until January 2004, five PD qualification sections have been held. The detection accuracy and uncertainty of flaw length sizing of UT were calculated according to the data provided by the examinees. Based on the available data, the flaw detection accuracy was about 89% for both stainless steel and carbon steel. However, the uncertainty of flaw length sizing varied with test piece material and flaw orientation. This analysis can be a reference for related organizations to gain more insight information of UT results. (author)

  10. Testing Solutions for Adult Film Performers.

    Science.gov (United States)

    Bergman, Zachary R

    2014-01-01

    The majority of the nation's adult films are produced in California, and within California, most production occurs in Los Angeles. In order to regulate that content, the County of Los Angeles passed the Safer Sex in the Adult Film Industry Act (Measure B) by way of referendum in November 2012. Measure B requires that adult film producers wishing to film in Los Angeles County obtain permits from the Los Angeles County Department of Public Health, and it also mandates that adult film performers use condoms while filming and "engaging in anal or vaginal sexual intercourse." Nevertheless, between August 2013 and January 2014, several adult film performers in California tested positive for HIV, and the threat of infection remains. Although Measure B is not the best way forward for Los Angeles County, elements of the ordinance should be incorporated into future legislative efforts. Given the economic ramifications of industry flight due to more localized regulations, this Note concludes that California should pass statewide comprehensive reform. Any such new legislation must treat "independent contractors," the classification generally used for adult film performs, as if they were regular employees. Legislation should also couple mandatory testing mechanisms with provisions granting performers the right to choose whether they use condoms. Finally, legislation must include mechanisms that ensure performers' preferences are not improperly tainted by outside forces and pressures. While there will always be risks associated with the production of adult content, if undertaken, these reforms could significantly mitigate those hazards.

  11. Status and test report on the LANL-Boeing APLE/HPO flying-wire beam-profile monitor. Status report

    Energy Technology Data Exchange (ETDEWEB)

    Wilke, M.; Barlow, D.; Fortgang, C.; Gilpatrick, J.; Meyer, R.; Rendon, A.; Warren, D. [Los Alamos National Lab., NM (United States); Greegor, R. [Boeing Co., Seattle, WA (United States)

    1994-07-01

    The High-Power Oscillator (HPO) demonstration of the Average Power Laser Experiment (APLE) is a collaboration by Los Alamos National Laboratory and Boeing to demonstrate a 10 kW average power, 10 {mu}m free electron laser (FEL). As part of the collaboration, Los Alamos National Laboratory (LANL) is responsible for many of the electron beam diagnostics in the linac, transport, and laser sections. Because of the high duty factor and power of the electron beam, special diagnostics are required. This report describes the flying wire diagnostic required to monitor the beam profile during high-power, high-duty operation. The authors describe the diagnostic and prototype tests on the Los Alamos APLE Prototype Experiment (APEX) FEL. They also describe the current status of the flying wires being built for APLE.

  12. A Framework for Fully Automated Performance Testing for Smart Buildings

    DEFF Research Database (Denmark)

    Markoska, Elena; Johansen, Aslak; Lazarova-Molnar, Sanja

    2018-01-01

    , setup of performance tests has been manual and labor-intensive and has required intimate knowledge of buildings’ complexity and systems. The emergence of the concept of smart buildings has provided an opportunity to overcome this restriction. In this paper, we propose a framework for automated......A significant proportion of energy consumption by buildings worldwide, estimated to ca. 40%, has yielded a high importance to studying buildings’ performance. Performance testing is a mean by which buildings can be continuously commissioned to ensure that they operate as designed. Historically...... performance testing of smart buildings that utilizes metadata models. The approach features automatic detection of applicable performance tests using metadata queries and their corresponding instantiation, as well as continuous commissioning based on metadata. The presented approach has been implemented...

  13. Physical fitness as an indicator of health status and its relationship to academic performance during the prepubertal period

    Directory of Open Access Journals (Sweden)

    Francisco Javier Fonseca del Pozo

    2017-09-01

    Full Text Available Background: Physical activity (PA is considered one of the most important determinants of the health status in children, and predictor of morbidity/mortality in adults. The aim is to examine the relationship between physical fitness (PF, PA, obesity and academic performance (AP in primary school children Methods: Cross-sectional studies including 91 primary school students, aged 9 to 12 years, from the province of Córdoba. Data was collected from April to June 2014. We measured PF using part of the EUROFIT fitness testing battery. The level of PA was measured as low or high PF and the level of obesity was measured using body mass index, waist circumference, percentage offal mass, lean body mass, percentage of lean mass and basal metabolism. AP by scores on the second quarter was based on the total average of scores of basic subjects and other subjects, including physical education. Cognitive performance was assessed by the Spanish overall and factorial intelligence test.Results: The results of AP were positively related to levels of PF. Students who achieve better PF score better in Maths, (P=0.019, Natural Sciences (P=0.024, Religion (P=0.018 and Physical Education (P<0.001. A direct association between maximal aerobic capacity with Mathematics (r=0.325, P=0.02, AP (r=0.349, P=0.001 and cognitive performance (CP(r=0.312, P=0.003 was observed. There was also a direct association of better jump tests with higher AP (r=0.328, P=0.002.Conclusion: The AP is associated with higher levels of fitness. Therefore, the education system should consider implementing curriculum strategies favouring the improvement of the PF, and therefore the health and AP of students.

  14. Energy Monitoring and Control Systems--Performance Verification and Endurance Test Procedures.

    Science.gov (United States)

    1982-12-01

    EM-; tK2 s) trave h.en loadted in qvstem sit ~rp sm:l , o,1 ti-’.~ -1 rouiitthe factoz’, lest. E.VEF.NT Comnmwid the system to display the status of...contractor correction of all outstanding deficiencies . 163 TEST NO: END-i Page I of 1 OBJECTIVE: To demonstrate EMCS normal mode operation 24 TITLE: Endurance

  15. The Relationship between Tests of Neurocognition and Performance on a Laparoscopic Simulator

    Directory of Open Access Journals (Sweden)

    Oumar Kuzbari

    2010-01-01

    Full Text Available Objective. To estimate if there is a relationship between the results of tests of neurocognition and performance on a laparoscopic surgery simulator. Methods and Materials. Twenty participants with no prior laparoscopic experience had baseline cognitive tests administered (Trail Making Test, Part A and B (TMT-A and TMT-B, Grooved Peg Board Test, Symbol Digit Modalities Test, Symbol Digit Recall Test, and Stroop Interference Test, completed a demographic questionnaire, and then performed laparoscopy using a simulator. We correlated the results of cognitive tests with laparoscopic surgical performance. Results. One cognitive test sensitive to frontal lobe function, TMT-A, significantly correlated with laparoscopic surgical performance on the simulator (correlation coefficient of 0.534 with P<.05. However, the correlation between performance and other cognitive tests (TMT-B, Grooved Peg Board Test, Symbol Digit Modalities Test, Symbol Digit Recall Test, and Stroop Interference Test was not statistically significant. Conclusion. Laparoscopic performance may be related to measures of frontal lobe function. Neurocognitive tests may predict motor skills abilities and performance on laparoscopic simulator.

  16. Hardware and software status of QCDOC

    International Nuclear Information System (INIS)

    Boyle, P.A.; Chen, D.; Christ, N.H.; Clark, M.; Cohen, S.D.; Cristian, C.; Dong, Z.; Gara, A.; Joo, B.; Jung, C.; Kim, C.; Levkova, L.; Liao, X.; Liu, G.; Mawhinney, R.D.; Ohta, S.; Petrov, K.; Wettig, T.; Yamaguchi, A.

    2004-01-01

    QCDOC is a massively parallel supercomputer whose processing nodes are based on an application-specific integrated circuit (ASIC). This ASIC was custom-designed so that crucial lattice QCD kernels achieve an overall sustained performance of 50% on machines with several 10,000 nodes. This strong scalability, together with low power consumption and a price/performance ratio of $1 per sustained MFlops, enable QCDOC to attack the most demanding lattice QCD problems. The first ASICs became available in June of 2003, and the testing performed so far has shown all systems functioning according to specification. We review the hardware and software status of QCDOC and present performance figures obtained in real hardware as well as in simulation

  17. The study of the energetic performance in test cycles

    Science.gov (United States)

    Rentea, Cristian; Tuca, Alexandra; Oprean, Mircea; Marius, Bataus

    2017-10-01

    One of the most important subsystems of modern passenger cars is the transmission. This paper aims to investigate the global performances of a modern transmission in different test cycles including the newly introduced WLTC (Worldwide Harmonized Light Vehicles Test Cycle). The study is done using a complex model developed in a performant simulation environment. Transmission efficiency calculation is emphasized, the efficiency being considered variable depending on engine torque, engine speed and gear ratio. The main important parameters (vehicle speed fluctuation, overall transmission efficiency, fuel consumption ratio) needed to compare test cycles and the transmissions performance are determined.

  18. Verification Test of Hydraulic Performance for Reactor Coolant Pump

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Jun; Kim, Jae Shin; Ryu, In Wan; Ko, Bok Seong; Song, Keun Myung [Samjin Ind. Co., Seoul (Korea, Republic of)

    2010-01-15

    According to this project, basic design for prototype pump and model pump of reactor coolant pump and test facilities has been completed. Basic design for prototype pump to establish structure, dimension and hydraulic performance has been completed and through primary flow analysis by computational fluid dynamics(CFD), flow characteristics and hydraulic performance have been established. This pump was designed with mixed flow pump having the following design requirements; specific velocity(Ns); 1080.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 3115m{sup 3}/h, total head ; 26.3m, pump speed; 1710rpm, pump efficiency; 77.0%, Impeller out-diameter; 349mm, motor output; 360kw, design pressure; 17MPaG. The features of the pump are leakage free due to no mechanical seal on the pump shaft which insures reactor's safety and law noise level and low vibration due to no cooling fan on the motor which makes eco-friendly product. Model pump size was reduced to 44% of prototype pump for the verification test for hydraulic performance of reactor coolant pump and was designed with mixed flow pump and canned motor having the following design requirements; specific speed(NS); 1060.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 539.4m{sup 3}/h, total head; 21.0m, pump speed; 3476rpm, pump efficiency; 72.9%, Impeller out-diameter; 154mm, motor output; 55kw, design pressure; 1.0MPaG. The test facilities were designed for verification test of hydraulic performance suitable for pump performance test, homologous test, NPSH test(cavitation), cost down test and pressure pulsation test of inlet and outlet ports. Test tank was designed with testing capacity enabling up to 2000m{sup 3}/h and design pressure 1.0MPaG. Auxiliary pump was designed with centrifugal pump having capacity; 1100m{sup 3}/h, total head; 42.0m, motor output; 190kw

  19. Cassini Radar EQM Model: Instrument Description and Performance Status

    Science.gov (United States)

    Borgarelli, L.; Faustini, E. Zampolini; Im, E.; Johnson, W. T. K.

    1996-01-01

    The spaeccraft of the Cassini Mission is planned to be launched towards Saturn in October 1997. The mission is designed to study the physical structure and chemical composition of Titan. The results of the tests performed on the Cassini radar engineering qualification model (EQM) are summarized. The approach followed in the verification and evaluation of the performance of the radio frequency subsystem EQM is presented. The results show that the instrument satisfies the relevant mission requirements.

  20. Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Buttner, William J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hartmann, Kevin S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Schmidt, Kara [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cebolla, Rafeal O [Joint Research Centre, Petten, the Netherlands; Weidner, Eveline [Joint Research Centre, Petten, the Netherlands; Bonato, Christian [Joint Research Centre, Petten, the Netherlands

    2017-11-06

    Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of

  1. Testing prospect theory in students’ performance

    OpenAIRE

    Pérez Galdón, Patricia; Nicolau, Juan Luis

    2013-01-01

    This paper tests the existence of ‘reference dependence’ and ‘loss aversion’ in students’ academic performance. Accordingly, achieving a worse than expected academic performance would have a much stronger effect on students’ (dis)satisfaction than obtaining a better than expected grade. Although loss aversion is a well-established finding, some authors have demonstrated that it can be moderated – diminished, to be precise–. Within this line of research, we also examine whether the students’ e...

  2. Development of performance tests for an automated MC and A system

    International Nuclear Information System (INIS)

    Kok, K.D.; Klingensmith, R.W.; Riffle, W.; Carver, R.D.; Schumacher, S.S.; Lavender, J.C.; Smith, B.W.

    1988-01-01

    Performance tests of MC and A systems using computers are described, and some example scenarios are discussed. Facility personnel or an external inspection group may use performance tests to evaluate MC and A capabilities under actual operating conditions. This paper addresses test elements common to both user groups. Performance tests consist of scenario development, security, and safety measures, conduct, and evaluation. Because exercises often test scenarios against which the MC and A system is protecting, they may require additional security and safety measures. Computer systems enhance MC and A by providing greater speed, increased precision, and automated checks. Performance tests for MC and A systems using computers differ from performance tests employing manual data systems in that the scenarios must anticipate computer actions rather than utilize controllers to adjust the scenario

  3. The influence of learning styles, enrollment status and gender on academic performance of optometry undergraduates.

    Science.gov (United States)

    Prajapati, Bhavna; Dunne, Mark; Bartlett, Hannah; Cubbidge, Robert

    2011-01-01

    This cross-sectional study was designed to determine whether the academic performance of optometry undergraduates is influenced by enrollment status, learning style or gender. Three hundred and sixty undergraduates in all 3 years of the optometry degree course at Aston University during 2008-2009 were asked for their informed consent to participate in this study. Enrollment status was known from admissions records. An Index of Learning Styles (http://www4.nscu.edu/unity/lockers/users/f/felder/public/Learning-Styles.html) determined learning style preference with respect to four different learning style axes; active-reflective, sensing-intuitive, visual-verbal and sequential-global. The influence of these factors on academic performance was investigated. Two hundred and seventy students agreed to take part (75% of the cohort). 63% of the sample was female. There were 213 home non-graduates (entrants from the UK or European Union without a bachelor's degree or higher), 14 home graduates (entrants from the UK or European Union with a bachelor's degree or higher), 28 international non-graduates (entrants from outside the UK or European Union without a bachelor's degree or higher) and 15 international graduates (entrants from outside the UK or European Union with a bachelor's degree or higher). The majority of students were balanced learners (between 48% and 64% across four learning style axes). Any preferences were towards active, sensing, visual and sequential learning styles. Of the factors investigated in this study, learning styles were influenced by gender; females expressed a disproportionate preference for the reflective and visual learning styles. Academic performance was influenced by enrollment status; international graduates (95% confidence limits: 64-72%) outperformed all other student groups (home non graduates, 60-62%; international non graduates, 55-63%) apart from home graduates (57-69%). Our research has shown that the majority of optometry students

  4. Physical fitness as an indicator of health status and its relationship to academic performance during the prepubertal period.

    Science.gov (United States)

    Fonseca Del Pozo, Francisco Javier; Alonso, Joaquín Valle; Álvarez, Manuel Vaquero; Orr, Siobhan; Cantarero, Francisco Jesús Llorente

    2017-01-01

    Background: Physical activity (PA) is considered one of the most important determinants of the health status in children, and predictor of morbidity/mortality in adults. The aim is to examine the relationship between physical fitness (PF), PA, obesity and academic performance (AP) in primary school children. Methods: Cross-sectional studies including 91 primary school students, aged 9 to 12 years, from the province of Córdoba. Data was collected from April to June 2014. We measured PF using part of the EUROFIT fitness testing battery. The level of PA was measured as low or high PF and the level of obesity was measured using body mass index, waist circumference, percentage of fat mass, lean body mass, percentage of lean mass and basal metabolism. AP by scores on the second quarter was based on the total average of scores of basic subjects and other subjects, including physical education. Cognitive performance was assessed by the Spanish overall and factorial intelligence test. Results: The results of AP were positively related to levels of PF. Students who achieve better PF score better in Maths, (P=0.019), Natural Sciences (P=0.024), Religion (P=0.018) and Physical Education (Plevels of fitness. Therefore, the education system should consider implementing curriculum strategies favouring the improvement of the PF, and therefore the health and AP of students.

  5. The installation and performance test of the surveillance system for DUPIC facility

    International Nuclear Information System (INIS)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system

  6. The installation and performance test of the surveillance system for DUPIC facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system.

  7. Dynamic Performance Characteristic Tests of Real Scale Lead Rubber Bearing for the Evaluation of Performance Criteria

    International Nuclear Information System (INIS)

    Kim, Min Kyu; Kim, Jung-Han; Choi, In-Kil

    2014-01-01

    Dynamic characteristic tests of full scale lead rubber bearing were performed for the evaluation of performance criteria of isolation system for nuclear power plants. For the dynamic test for a full scale rubber bearing, two 1500mm diameter lead rubber bearings were manufactured. The viewpoints of this dynamic test are determination of an ultimate shear strain level of lead rubber bearing, behavior of rubber bearing according to static and dynamic input motion, sinusoidal and random (earthquake) motion, and 1-dimentional and 2-dimensional input motion. In this study, seismic isolation device tests were performed for the evaluation of performance criteria of isolation system. Through this test, it can be recognized that in the case of considering a mechanical property test, dynamic and multi degree of loading conditions should be determined. But these differences should be examined how much affect to the global structural behavior

  8. Performance test of a ceramic turbo-viscous pump

    International Nuclear Information System (INIS)

    Abe, Tetsuya; Hiroki, Seiji; Murakami, Yoshio; Shiraishi, Shigeyuki; Totoura, Sadayuki; Ohtaki, Takashi.

    1994-01-01

    In the special fields of nuclear fusion facilities and semiconductor production installation, the development of new vacuum pumps which can cope with strong magnetic fields, high temperature gas and corrosive gas is demanded. Mitsubishi Heavy Industries Ltd. has advanced the development of ceramic turbo-molecular pumps and ceramic turbo-viscous pumps, which use ceramic rotors and gas bearings since 1985. The evaluation test of the ceramic turbo-viscous vacuum pump CT-3000H which can evacuate from atmospheric pressure to high vacuum with one pump was carried out, and the experimental results on the performance and the reliability were obtained, therefore, those are reported in this paper. The structure, specification and features of the CT-3000H are shown. The exhaust performance test of the pump was carried out in conformity with the standard of the Vacuum Society of Japan, JVIS 005 'Method of performance test for turbo-molecular pumps'. The gases used were nitrogen and helium. The results are shown. The exhaust test from atmospheric pressure was carried out by two methods, and the results are shown. (K.I.)

  9. Development of a grinding-specific performance test set-up

    DEFF Research Database (Denmark)

    Olesen, C. G.; Larsen, B. H.; Andresen, E. L.

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding...... demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding...... and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding...

  10. Trajectories of Symptom Clusters, Performance Status, and Quality of Life During Concurrent Chemoradiotherapy in Patients With High-Grade Brain Cancers.

    Science.gov (United States)

    Kim, Sang-Hee; Byun, Youngsoon

    Symptom clusters must be identified in patients with high-grade brain cancers for effective symptom management during cancer-related therapy. The aims of this study were to identify symptom clusters in patients with high-grade brain cancers and to determine the relationship of each cluster with the performance status and quality of life (QOL) during concurrent chemoradiotherapy (CCRT). Symptoms were assessed using the Memorial Symptom Assessment Scale, and the performance status was evaluated using the Karnofsky Performance Scale. Quality of life was assessed using the Functional Assessment of Cancer Therapy-General. This prospective longitudinal survey was conducted before CCRT and at 2 to 3 weeks and 4 to 6 weeks after the initiation of CCRT. A total of 51 patients with newly diagnosed primary malignant brain cancer were included. Six symptom clusters were identified, and 2 symptom clusters were present at each time point (ie, "negative emotion" and "neurocognitive" clusters before CCRT, "negative emotion and decreased vitality" and "gastrointestinal and decreased sensory" clusters at 2-3 weeks, and "body image and decreased vitality" and "gastrointestinal" clusters at 4-6 weeks). The symptom clusters at each time point demonstrated a significant relationship with the performance status or QOL. Differences were observed in symptom clusters in patients with high-grade brain cancers during CCRT. In addition, the symptom clusters were correlated with the performance status and QOL of patients, and these effects could change during CCRT. The results of this study will provide suggestions for interventions to treat or prevent symptom clusters in patients with high-grade brain cancer during CCRT.

  11. Reactivity Insertion Accident (RIA) Capability Status in the BISON Fuel Performance Code

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, Richard L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Folsom, Charles Pearson [Idaho National Lab. (INL), Idaho Falls, ID (United States); Pastore, Giovanni [Idaho National Lab. (INL), Idaho Falls, ID (United States); Veeraraghavan, Swetha [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-05-01

    One of the Challenge Problems being considered within CASL relates to modelling and simulation of Light Water Reactor LWR) fuel under Reactivity Insertion Accident (RIA) conditions. BISON is the fuel performance code used within CASL for LWR fuel under both normal operating and accident conditions, and thus must be capable of addressing the RIA challenge problem. This report outlines required BISON capabilities for RIAs and describes the current status of the code. Information on recent accident capability enhancements, application of BISON to a RIA benchmark exercise, and plans for validation to RIA behavior are included.

  12. Performance Testing Methodology for Safety-Critical Programmable Logic Controller

    International Nuclear Information System (INIS)

    Kim, Chang Ho; Oh, Do Young; Kim, Ji Hyeon; Kim, Sung Ho; Sohn, Se Do

    2009-01-01

    The Programmable Logic Controller (PLC) for use in Nuclear Power Plant safety-related applications is being developed and tested first time in Korea. This safety-related PLC is being developed with requirements of regulatory guideline and industry standards for safety system. To test that the quality of the developed PLC is sufficient to be used in safety critical system, document review and various product testings were performed over the development documents for S/W, H/W, and V/V. This paper provides the performance testing methodology and its effectiveness for PLC platform conducted by KOPEC

  13. Status of prototype rupture disc testing in the large leak test rig

    International Nuclear Information System (INIS)

    Amos, J.C.

    1979-09-01

    The prototype CRBRP double membrane rupture disc assembly is being performance tested in conjunction with the LLTR Series II Large Leak Program. In May 1979, the double membrane disc assembly was inadvertently activated during sodium system pressure instrument calibration. This experience indicated that the rupture disc burst at essentially the design burst pressure when a gradually increasing state pressure was applied. The area of membrane opening was found to be about 25 to 30% of the cross-sectional area. In July 1979, the disc assembly was again tested (this time in a single membrane configuration) in conjunction with the first LLTR Series II Test A-1a (inert gas injection). Test data indicated that the disc burst in about 35 ms at essentially the design burst pressure with an opening of about 30% of the cross-sectional area. The pressure immediately downstream of the disc dropped below atmospheric pressure following the rupture tube event (releasing high pressure nitrogen into sodium) for about 1.5 seconds before increasing to a maximum of 30 psig. This behavior raises a question on the adequacy of a downstream pressure device for rapid sensing of disc rupture and initiating plant shutdown following a large SWR event. 14 figures

  14. 48 CFR 509.308-1 - Testing performed by the contractor.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Testing performed by the... ADMINISTRATION COMPETITION AND ACQUISITION PLANNING CONTRACTOR QUALIFICATIONS First Article Testing and Approval 509.308-1 Testing performed by the contractor. In FSS solicitations and contracts that will require...

  15. Assessing health status in COPD. A head-to-head comparison between the COPD assessment test (CAT) and the clinical COPD questionnaire (CCQ)

    NARCIS (Netherlands)

    Tsiligianni, Ioanna G.; van der Molen, Thys; Moraitaki, Despoina; Lopez, Ilaine; Kocks, Janwillem W. H.; Karagiannis, Konstantinos; Siafakas, Nikolaos; Tzanakis, Nikolaos

    2012-01-01

    Background: Health status provides valuable information, complementary to spirometry and improvement of health status has become an important treatment goal in COPD management. We compared the usefulness and validity of the COPD Assessment Test (CAT) and the Clinical COPD Questionnaire (CCQ), two

  16. Motivation and performance in physical education: an experimental test.

    Science.gov (United States)

    Moreno, Juan A; González-Cutre, David; Martín-Albo, José; Cervelló, Eduardo

    2010-01-01

    The purpose of this study was to analyse, experimentally, the relationships between motivation and performance in a lateral movement test in physical education. The study group consisted of 363 students (227 boys and 136 girls), aged between 12 and 16, who were randomly divided into three groups: an experimental group in which an incremental ability belief was induced, another experimental group in which an entity ability belief was induced, and a control group where there was no intervention. Measurements were made of situational intrinsic motivation, perceived competence in executing the task and performance. The results revealed that the incremental group reported higher scores on the situational intrinsic motivation scale. The entity group demonstrated better performance in the first test attempt than the incremental group but, in the second attempt, the performance was similar in the different groups. Perhaps the initial differences in performance disappeared because the incremental group counted on improving in the second attempt. These results are discussed in relation to the intensity with which the teacher conveys information relating to incremental ability belief of the pupil to increase intrinsic motivation and performance. Key pointsThe incremental group showed more situational intrinsic motivation.The entity group showed higher performance in the first test attempt, but significant differences disappeared in the second attempt.It seems that this incremental belief and greater intrinsic motivation made the students trust they would improve their performance in the second attempt at the lateral movement test.

  17. Testing for Distortions in Performance Measures

    DEFF Research Database (Denmark)

    Sloof, Randolph; Van Praag, Mirjam

    2015-01-01

    Distorted performance measures in compensation contracts elicit suboptimal behavioral responses that may even prove to be dysfunctional (gaming). This paper applies the empirical test developed by Courty and Marschke (Review of Economics and Statistics, 90, 428-441) to detect whether the widely...

  18. Testing for Distortions in Performance Measures

    DEFF Research Database (Denmark)

    Sloof, Randolph; Van Praag, Mirjam

    Distorted performance measures in compensation contracts elicit suboptimal behavioral responses that may even prove to be dysfunctional (gaming). This paper applies the empirical test developed by Courty and Marschke (2008) to detect whether the widely used class of Residual Income based performa...

  19. NESTOR: A status report

    CERN Document Server

    Anassontzis, E G; Barone, M; Foudas, C; Grammatikakis, G; Katsanevas, S; Kourkoumelis, C; Manousakis-Katsikakis, A; Resvanis, L K; Siotis, I; Sotiriou, S A; Voulgaris, G; Minkowski, P; Grieder, P K F; Ball, A E; Bottai, S; Cartacci, A M; Monteleoni, B; Naumov, Vadim A; Trasatti, L; Fahrun, E; Keusen, U; Koske, P; Rathlev, J; Schmidt, N P; Voight, G; Bezrukov, Leonid B; Butkevich, A V; Dedenko, L G; Karaevsky, S K; Mironovich, A A; Zakharov, L M; Zheleznykh, I M; Zhukov, V A; Demidova, T A; Deineko, A O; Eremeev, A P; Paka, V T; Permyakov, A A; Platonov, M N; Rukol, V Kh; Sheremet, N A; Surin, N M; Albul, V I; Ledenev, V V

    2000-01-01

    NESTOR is an underwater neutrino astrophysics laboratory to be located in the international waters of the southwest of Greece. The first phase of this experiment is the construction and deployment of one hexagonal tower consisting of 168 optical modules, with effective are of 20000m2 for E ⩾ TeV neutrinos. Over the past few years detailed studies of the site have been carried out while many tests have been performed. The current status of the preparation of the experiment and the future plans will be presented.

  20. Light water reactor pressure isolation valve performance testing

    International Nuclear Information System (INIS)

    Neely, H.H.; Jeanmougin, N.M.; Corugedo, J.J.

    1990-07-01

    The Light Water Reactor Valve Performance Testing Program was initiated by the NRC to evaluate leakage as an indication of valve condition, provide input to Section XI of the ASME Code, evaluate emission monitoring for condition and degradation and in-service inspection techniques. Six typical check and gate valves were purchased for testing at typical plant conditions (550F at 2250 psig) for an assumed number of cycles for a 40-year plant lifetime. Tests revealed that there were variances between the test results and the present statement of the Code; however, the testing was not conclusive. The life cycle tests showed that high tech acoustic emission can be utilized to trend small leaks, that specific motor signature measurement on gate valves can trend and indicate potential failure, and that in-service inspection techniques for check valves was shown to be both feasible and an excellent preventive maintenance indicator. Life cycle testing performed here did not cause large valve leakage typical of some plant operation. Other testing is required to fully understand the implication of these results and the required program to fully implement them. (author)

  1. 48 CFR 509.308-2 - Testing performed by the Government.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Testing performed by the... ADMINISTRATION COMPETITION AND ACQUISITION PLANNING CONTRACTOR QUALIFICATIONS First Article Testing and Approval 509.308-2 Testing performed by the Government. In FSS solicitations and contracts that will have the...

  2. WhalePower tubercle blade power performance test report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-15

    Toronto-based WhalePower Corporation has developed turbine blades that are modeled after humpback whale flippers. The blades, which incorporate tubercles along the leading edge of the blade, have been fitted to a Wenvor 25 kW turbine installed in North Cape, Prince Edward Island at a test site for the Wind Energy Institute of Canada (WEICan). A test was conducted to characterize the power performance of the prototype wind turbine. This report described the wind turbine configuration with particular reference to turbine information, power rating, blade information, tower information, control systems and grid connections. The test site was also described along with test equipment and measurement procedures. Information regarding power output as a function of wind speed was included along with power curves, power coefficient and annual energy production. The results for the power curve and annual energy production contain a level of uncertainty. While measurements for this test were collected and analyzed in accordance with International Electrotechnical Commission (IEC) standards for performance measurements of electricity producing wind turbines (IEC 61400-12-1), the comparative performance data between the prototype WhalePower wind turbine blade and the Wenvor standard blade was not gathered to IEC data standards. Deviations from IEC-61400-12-1 procedures were listed. 6 tabs., 16 figs., 3 appendices.

  3. High Performance Computing Modernization Program Kerberos Throughput Test Report

    Science.gov (United States)

    2017-10-26

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/5524--17-9751 High Performance Computing Modernization Program Kerberos Throughput Test ...NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2. REPORT TYPE1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 6. AUTHOR(S) 8. PERFORMING...PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT High Performance Computing Modernization Program Kerberos Throughput Test Report Daniel G. Gdula* and

  4. Small-scale tunnel test for blast performance

    International Nuclear Information System (INIS)

    Felts, J E; Lee, R J

    2014-01-01

    The data reported here provide a validation of a small-scale tunnel test as a tool to guide the optimization of new explosives for blast performance in tunnels. The small-scale arrangement consisted of a 2-g booster and 10-g sample mounted at the closed end of a 127 mm diameter by 4.6-m long steel tube with pressure transducers along its length. The three performance characteristics considered were peak pressure, initial energy release, and impulse. The relative performance from five explosives was compared to that from a 1.16-m diameter by 30-m long tunnel that used 2.27-kg samples. The peak pressure values didn't correlate between the tunnels. Partial impulse for the explosives did rank similarly. The initial energy release was determined from a one-dimensional point-source analysis, which nearly tracked with impulse suggesting additional energy released further down the tunnel for some explosives. This test is a viable tool for optimizing compositional variations for blast performance in target scenarios of similar geometry.

  5. Integrated Performance Testing Workshop, Modules 6 - 11

    Energy Technology Data Exchange (ETDEWEB)

    Leach, Janice; Torres, Teresa M.

    2012-10-01

    These modules cover performance testing of: Interior Detection Systems; Access Controls; Exterior Detection Systems; Video Assessment Systems; SNM / Contraband Detection Systems; Access Delay Elements

  6. Relationship Between the Functional Status Scale and the Pediatric Overall Performance Category and Pediatric Cerebral Performance Category Scales FREE

    Science.gov (United States)

    Pollack, Murray M.; Holubkov, Richard; Funai, Tomohiko; Clark, Amy; Moler, Frank; Shanley, Thomas; Meert, Kathy; Newth, Christopher J. L.; Carcillo, Joseph; Berger, John T.; Doctor, Allan; Berg, Robert A.; Dalton, Heidi; Wessel, David L.; Harrison, Rick E.; Dean, J. Michael; Jenkins, Tammara L.

    2015-01-01

    Importance Functional status assessment methods are important as outcome measures for pediatric critical care studies. Objective To investigate the relationships between the 2 functional status assessment methods appropriate for large-sample studies, the Functional Status Scale (FSS) and the Pediatric Overall Performance Category and Pediatric Cerebral Performance Category (POPC/PCPC) scales. Design, Setting, and Participants Prospective cohort study with random patient selection at 7 sites and 8 children’s hospitals with general/medical and cardiac/cardiovascular pediatric intensive care units (PICUs) in the Collaborative Pediatric Critical Care Research Network. Participants included all PICU patients younger than 18 years. Main Outcomes and Measures Functional Status Scale and POPC/PCPC scores determined at PICU admission (baseline) and PICU discharge. We investigated the association between the baseline and PICU discharge POPC/PCPC scores and the baseline and PICU discharge FSS scores, the dispersion of FSS scores within each of the POPC/PCPC ratings, and the relationship between the FSS neurologic components (FSS-CNS) and the PCPC. Results We included 5017 patients. We found a significant (P < .001) difference between FSS scores in each POPC or PCPC interval, with an FSS score increase with each worsening POPC/PCPC rating. The FSS scores for the good and mild disability POPC/PCPC ratings were similar and increased by 2 to 3 points for the POPC/PCPC change from mild to moderate disability, 5 to 6 points for moderate to severe disability, and 8 to 9 points for severe disability to vegetative state or coma. The dispersion of FSS scores within each POPC and PCPC rating was substantial and increased with worsening POPC and PCPC scores. We also found a significant (P < .001) difference between the FSS-CNS scores between each of the PCPC ratings with increases in the FSS-CNS score for each higher PCPC rating. Conclusions and Relevance The FSS and POPC/PCPC system

  7. Socioeconomic status and health of immigrants.

    Science.gov (United States)

    Vacková, Jitka; Brabcová, Iva

    2015-01-01

    The aim of this article is to acquaint the general public with select socioeconomic status (SES) parameters (type of work, education level, employment category, and net monthly income) of select nationalities (Ukrainians, Slovaks, Vietnamese, Poles, and Russians) from a total of 1,014 immigrants residing in the Czech Republic. It will also present a subjective assessment of socioeconomic status and its interconnection with subjective assessment of health status. This work was carried out as part of the "Social determinants and their impact on the health of immigrants living in the Czech Republic" project (identification number LD 13044), which was conducted under the auspices of the European Cooperation in Science and Technology (COST) agency. Quantitative methodology in the form of a questionnaire was selected to facilitate the research aim. Data was processed using the Statistical Package for Social Sciences (SPSS), version 16.0 (SPSS, Inc., Chicago, IL, USA). Statistical analyses were performed using the Pearson chi-square test, adjusted residual analysis, and multivariate correspondence analysis. The results of these tests demonstrated a statistically significant relationship between subjective assessments of socioeconomic status and the following related select characteristics: type of work performed (manual/intellectual), employment categories, education, and net monthly income. Results indicate that those situated lowest on the socioeconomic ladder feel the poorest in terms of health; not only from a subjective perspective, but also in terms of objective parameter comparisons (e.g. manual laborers who earn low wages). As the level of subjective SES assessment increases, the level of subjective health assessment increases, as well. Thus, the relationship has a natural gradient, as was described by Wilkinson and Marmot in 2003. Our study found no evidence of a healthy immigrant effect. Therefore, it was not possible to confirm that health status deteriorates

  8. 46 CFR 57.06-3 - Method of performing production testing.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Method of performing production testing. 57.06-3 Section 57.06-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING Production Tests § 57.06-3 Method of performing production testing. (a) Except as...

  9. Measurement protocol for performance testing of the determination of tritium in water

    International Nuclear Information System (INIS)

    1993-01-01

    In the Health and Safety Executive's ''Requirements for the Approval of Dosimetry Services under the Ionising Radiations Regulations 1985'', it is stipulated that dosimetry services seeking approval must show that they have successfully completed a performance test. The services must arrange for the tests to be carried out on application and thereafter every 18 months, by a laboratory which has received accreditation from the National Measurement Accreditation Service (NAMAS) for conducting the performance tests. Accreditation by NAMAS ensures that the laboratories carrying out the performance tests are of an appropriate standard. It includes requirements for quality control and audit procedures, to authenticate traceability to national standards, and to provide a reliable record keeping system for the performance tests. A list of laboratories which are accredited by NAMAS for carrying out HSE published performance tests will be maintained by the Secretary of the Dosimetry Services Panel. The performance tests must be carried out to published protocols. The results have to be expressed in terms of bias and random error, as defined in HSE's criteria for performance tests. The purpose here is to provide a protocol for laboratories to conduct performance tests on dosimetry services performing tritium determinations in urine. The test is deliberately not exhaustive, instead it is a simple test allowing the basic performance of a service to be assessed for approval. (author)

  10. Status of CCTF test program

    International Nuclear Information System (INIS)

    Murao, Y.; Iguchi, T.; Sugimoto, J.; Akimoto, H.; Okubo, T.; Okabe, K.

    1984-01-01

    The cylindrical core test facility (CCTF) is one of the facilities of the large scale reflood test program which was initiated in April, 1976. The first series of the CCTF test (CCTF CORE I Test) was completed in April, 1981 and the second series (CCTF Core II Test) has been conducted since April, 1982. In the test, the following has been intended to be examined: (1) The conservativeness of the assumption of the safety analysis with the evaluation model (EM) code. (2) The refill and reflood phenomena for analytical modeling of thermo-hydrodynamics in the core and the system. (3) The validity of the models in the EM code and the application to the best estimate code development. In this paper, presented are the quantative evaluation of the REFLA code and the discussion of some CCTF Core II Test results. The REFLA code consists of REFLA-1D core code developed with the results of small scale tests and a simple system model developed with the results of the CCTF Core I Test. The CCTF Core II Test was perfored for developing more realistic model for the alternative ECCS as well as for the cold leg injection type ECCS

  11. Personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, C.G.

    2005-01-01

    Full text: The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11 (2002). Now in its third edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by US Nuclear Regulatory Commission (NRC) regulations. The US Department of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Department of Energy Laboratory Accreditation Program (DOELAP). A focus in recent years has been the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonization to US personal dosimeter processing testing. The testing philosophy of ANSI N13.11 has always combined elements of type testing and routine performance testing and is thus different from the testing philosophy used in the rest of the world. This unique philosophy is explored in detail in this presentation, along with trends in the development of the document to its present state. In addition, a look will be taken at what the future holds for the next revision of the document, scheduled to begin in 2005. (author)

  12. [Performance of normal young adults in two temporal resolution tests].

    Science.gov (United States)

    Zaidan, Elena; Garcia, Adriana Pontin; Tedesco, Maria Lucy Fraga; Baran, Jane A

    2008-01-01

    temporal auditory processing is defined as the perception of sound or of sound alteration within a restricted time interval and is considered a fundamental ability for the auditory perception of verbal and non verbal sounds, for the perception of music, rhythm, periodicity and in the discrimination of pitch, duration and of phonemes. to compare the performance of normal Brazilian adults in two temporal resolution tests: the Gaps-in-Noise Test (GIN) and the Random Gap Detection Test (RGDT), and to analyze potential differences of performance in these two tests. twenty-five college students with normal hearing (11 males and 14 females) and no history of educational, neurological and/or language problems, underwent the GIN and RGDT at 40dB SL. statistically significant gender effects for both tests were found, with female participants showing poorer performance on both temporal processing tests. In addition, a comparative analysis of the results obtained in the GIN and RGDT revealed significant differences in the threshold measures derived for these two tests. In general, significantly better gap detection thresholds were observed for both male and female participants on the GIN test when compared to the results obtained for the RGDT. male participants presented better performances on both RGDT and GIN, when compared to the females. There were no differences in performance between right and left ears on the GIN test. Participants of the present investigation, males and females, performed better on the GIN when compared to the RGDT. The GIN presented advantages over the RGDT, not only in terms of clinical validity and sensibility, but also in terms of application and scoring.

  13. Early-1990 status of performance assessment for the Waste Isolation Pilot Plant disposal system

    International Nuclear Information System (INIS)

    Bertram-Howery, S.G.; Swift, P.N.

    1991-07-01

    This paper summarizes the early-1990 status of the performance-assessment work being done to evaluate compliance of the Waste Isolation Pilot Plant with the U.S. Environmental Protection Agency regulation 40 CFR Part 191, Subpart B. This regulation sets environmental standards for radioactive waste disposal (Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes). As required by Subpart B, evaluations of compliance will include probabilistic numerical simulations of repository performance and qualitative judgments. Compliance appears uncertain only in the event of human intrusion into the repository after decommissioning. Issues affecting compliance following intrusion include properties of the plugs used to seal the intruding borehole, permeability and porosity of the waste, and possible pressurization of the repository by gas generated from the organic decomposition and corrosion of the waste and containers. Research is in progress to determine the probability of intrusion and to quantify parameter uncertainties needed to include these factors in simulations of repository performance. The Department of Energy (DOE) is following two strategies to assure compliance. First, passive marker systems will be designed and implemented to reduce the likelihood of intrusion and increase the likelihood that intruders will properly reseal the repository. Second, modifications to the form of the waste and the design of the repository to achieve acceptable performance if the intruding borehole is not adequately sealed will be designed. Goals include reductions in gas generation and waste permeability and porosity. Numerous modifications are technically possible. Work in progress will evaluate proposed modifications and recommend the most promising for further testing. The DOE is confident that compliance with Subpart B of 40 CFR 191 can be established using a combination of the two strategies

  14. Early-1990 status of performance assessment for the Waste Isolation Pilot Plant disposal system

    Energy Technology Data Exchange (ETDEWEB)

    Bertram-Howery, S G [Sandia National Laboratories, Albuquerque, NM (United States); Swift, P N [Tech Reps Inc., Albuquerque, NM (United States)

    1991-07-15

    This paper summarizes the early-1990 status of the performance-assessment work being done to evaluate compliance of the Waste Isolation Pilot Plant with the U.S. Environmental Protection Agency regulation 40 CFR Part 191, Subpart B. This regulation sets environmental standards for radioactive waste disposal (Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes). As required by Subpart B, evaluations of compliance will include probabilistic numerical simulations of repository performance and qualitative judgments. Compliance appears uncertain only in the event of human intrusion into the repository after decommissioning. Issues affecting compliance following intrusion include properties of the plugs used to seal the intruding borehole, permeability and porosity of the waste, and possible pressurization of the repository by gas generated from the organic decomposition and corrosion of the waste and containers. Research is in progress to determine the probability of intrusion and to quantify parameter uncertainties needed to include these factors in simulations of repository performance. The Department of Energy (DOE) is following two strategies to assure compliance. First, passive marker systems will be designed and implemented to reduce the likelihood of intrusion and increase the likelihood that intruders will properly reseal the repository. Second, modifications to the form of the waste and the design of the repository to achieve acceptable performance if the intruding borehole is not adequately sealed will be designed. Goals include reductions in gas generation and waste permeability and porosity. Numerous modifications are technically possible. Work in progress will evaluate proposed modifications and recommend the most promising for further testing. The DOE is confident that compliance with Subpart B of 40 CFR 191 can be established using a combination of the two strategies

  15. Dietary acid load and renal function have varying effects on blood acid-base status and exercise performance across age and sex.

    Science.gov (United States)

    Hietavala, Enni-Maria; Stout, Jeffrey R; Frassetto, Lynda A; Puurtinen, Risto; Pitkänen, Hannu; Selänne, Harri; Suominen, Harri; Mero, Antti A

    2017-12-01

    Diet composition influences acid-base status of the body. This may become more relevant as renal functional capacity declines with aging. We examined the effects of low (LD) versus high dietary acid load (HD) on blood acid-base status and exercise performance. Participants included 22 adolescents, 33 young adults (YA), and 33 elderly (EL), who followed a 7-day LD and HD in a randomized order. At the end of both diet periods the subjects performed a cycle ergometer test (3 × 10 min at 35%, 55%, 75%, and (except EL) until exhaustion at 100% of maximal oxygen uptake). At the beginning of and after the diet periods, blood samples were collected at rest and after all workloads. Oxygen uptake, respiratory exchange ratio (RER), and heart rate (HR) were monitored during cycling. In YA and EL, bicarbonate (HCO 3 - ) and base excess (BE) decreased over the HD period, and HCO 3 - , BE, and pH were lower at rest after HD compared with LD. In YA and EL women, HCO 3 - and BE were lower at submaximal workloads after HD compared with LD. In YA women, the maximal workload was 19% shorter and maximal oxygen uptake, RER, and HR were lower after HD compared with LD. Our data uniquely suggests that better renal function is associated with higher availability of bases, which may diminish exercise-induced acidosis and improve maximal aerobic performance. Differences in glomerular filtration rate between the subject groups likely explains the larger effects of dietary acid load in the elderly compared with younger subjects and in women compared with men.

  16. HIV Testing and Cross Border Migrant Vulnerability: Social Integration and Legal/Economic Status Among Cross Border Migrant Workers in Thailand.

    Science.gov (United States)

    Ford, Kathleen; Holumyong, Charamporn

    2016-04-01

    The objective of this paper was to identify factors related to the use of HIV testing among cross border migrants in Thailand. Two measures of vulnerability (social integration and legal/economic status) as well as HIV knowledge, risk behaviour, and demographic factors were tested for association with HIV testing. Data were drawn from a survey of 2600 sexually active migrants age 15-59 in multiple provinces of Thailand. The measures of social integration (AOR = 1.14(95 % CI 1.09, 1.20) female; AOR = 1.12 (95 %CI 1.05, 1.19) male) and legal-income status (AOR = 1.12 (95 % CI 1.07, 1.18) female; AOR = 1.31 (95 %CI 1.20, 1.42) male) were positively related to the odds of reporting an HIV test for both male and female migrants. Exposure to AIDS programming including attending an AIDS meeting and possessing AIDS knowledge was also related to an increase in HIV testing. In addition, reproductive health factors including sexual risk behavior and childbirth increased the rate of HIV testing.

  17. Mirror fusion test facility cryogenic system - performance, management approach, and present equipment status

    International Nuclear Information System (INIS)

    Slack, D.S.; Chronis, W.C.

    1988-01-01

    The cryogenic system for the MFTF is a helium refrigeration system that proved to be successful and cost effective. All operating objectives were met while remaining within a few percent of the initial cost and schedule plans. The management approach used at MFTF is assessed. Manpower levels, extent and type of industrial participation, and subcontractor specifications and interactions are reviewed along with highlights of system testing, documentation, and operation

  18. Pengaruh Pemberian Energi, Karbohidrat, Protein, Lemak terhadap Status Gizi dan Keterampilan Atlet Sepak Bola

    OpenAIRE

    Ramadhani, Renjani Gina; Murbawani, Etisa Adi

    2012-01-01

    Background: Good skills in soccer are very needed to accomplish the achievement. Nutritional status in soccer athletes can effect the performance on the match. Besides exercises, nutrition intake is considered to have an effect on the nutritional status and skills of soccer athletes. Objective: The purpose of this study was to determine the effect of food intake on nutritional status and skills of soccer athletes. Methods: An experimental study with one group pre and post test designed on soc...

  19. Castor-V/21 PWR spent fuel storage cask performance test

    International Nuclear Information System (INIS)

    Creer, J.M.; Schoonen, D.H.

    1986-01-01

    Performance testing of a CASTOR-V/21 PWR spent fuel storage cask manufactured by Gesellschaft fur Nuklear Service (GNS) was performed as part of a cooperative program between Virginia Power and the US Department of Energy. The performance test consisted of obtaining cask handling experience and heat transfer, shielding, and limited fuel integrity data. Five heat transfer test runs were performed with 21 Surry reactor spent fuel assemblies generating approximately 28 kW. Test runs were performed vacuum, nitrogen, and helium backfill environments with the cask in both vertical and horizontal orientations. Cask exterior surface gamma and neutron dose rates were measured with the cask fully loaded. Gas samples were obtained at the beginning and end of each run with nitrogen or helium environments to verify fuel integrity. The heat transfer performance of the CASTOR-V/21 cask was exceptionally good. Peak clad temperatures with helium and nitrogen environments with the cask in a vertical orientation and with helium with the cask in a horizontal orientation were less than 380 0 C. Vertical vacuum and horizontal nitrogen test runs resulted in peak clad temperatures over 380 0 , but the temperatures were not excessively high ( 0 C). The shielding performance of the cask met the design goal of less than 200 mrem/hr. Cask surface dose rates of <75 mrem/hr can easily be established with minor gamma shielding design refinements if desired. Gas samples obtained during testing indicated no leaking fuel rods were present in the cask. It was concluded that the cask performed satisfactorily from heat transfer and shielding perspectives

  20. Development of Out-pile Test Technology for Fuel Assembly Performance Verification

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Tae Hyun; In, W. K.; Oh, D. S. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)] (and others)

    2007-03-15

    Out-pile tests with full scale fuel assembly are to verify the design and to evaluate the performance of the final products. HTL for the hydraulic tests and FAMeCT for mechanical/structural tests were constructed in this project. The maximum operating conditions of HTL are 30 bar, 320 .deg. C, and 500 m3/hr. This facility can perform the pressure drop test, fuel assembly uplift test, and flow induced vibration test. FAMeCT can perform the bending and vibration tests. The verification of the developed facilities were carried out by comparing the reference data of the fuel assembly which was obtained at the Westinghouse Co. The compared data showed a good coincidence within uncertainties. FRETONUS was developed for high temperature and high pressure fretting wear simulator and performance test. A performance test was conducted for 500 hours to check the integrity, endurance, data acquisition capability of the simulator. The technology of turbulent flow analysis and finite element analysis by computation was developed. From the establishments of out-pile test facilities for full scale fuel assembly, the domestic infrastructure for PWR fuel development has been greatly upgraded.

  1. Prediction of 90 Day and Overall Survival after Chemoradiotherapy for Lung Cancer: Role of Performance Status and Body Composition.

    Science.gov (United States)

    Bowden, J C S; Williams, L J; Simms, A; Price, A; Campbell, S; Fallon, M T; Fearon, K C H

    2017-09-01

    If appropriate patients are to be selected for lung cancer treatment, an understanding of who is most at risk of adverse outcomes after treatment is needed. The aim of the present study was to identify predictive factors for 30 and 90 day mortality after chemoradiotherapy (CRT), and factors that were prognostic for overall survival. A retrospective cohort study of 194 patients with lung cancer who had undergone CRT in South East Scotland from 2008 to 2010 was undertaken. Gender, age, cancer characteristics, weight loss, body mass index (BMI), performance status (Eastern Cooperative Oncology Group; ECOG) and computed tomography-derived body composition variables were examined for prognostic significance using Cox's proportional hazards model and logistic regression. The median overall survival was 19 months (95% confidence interval 16.3, 21.7). Four of 194 patients died within 30 days of treatment completion, for which there were no independent predictive variables; 22/194 (11%) died within 90 days of treatment completion. BMI < 20 and ECOG performance status ≥2 were independent predictors of death within 90 days of treatment completion (P = 0.001 and P = 0.004, respectively). Patients with either BMI < 20 or ECOG performance status ≥ 2 had an odds ratio of death within 90 days of 5.97 (95% confidence interval 2.20, 16.19), rising to an odds ratio of 13.27 (1.70, 103.47) for patients with both BMI < 20 and ECOG performance status ≥ 2. Patients with low muscle attenuation had significantly reduced overall survival (P = 0.004); individuals with low muscle attenuation had a median survival of 15.2 months (95% confidence interval 12.7, 17.7) compared with 23.0 months (95% confidence interval 18.3, 27.8) for those with high muscle attenuation, equating to a hazard ratio of death of 1.62 (95% confidence interval 1.17, 2.23, P = 0.003). Poor performance status, low BMI and low muscle attenuation identify patients at increased risk of premature death after

  2. AAPM Medical Physics Practice Guideline 8.a.: Linear accelerator performance tests.

    Science.gov (United States)

    Smith, Koren; Balter, Peter; Duhon, John; White, Gerald A; Vassy, David L; Miller, Robin A; Serago, Christopher F; Fairobent, Lynne A

    2017-07-01

    The purpose of this guideline is to provide a list of critical performance tests in order to assist the Qualified Medical Physicist (QMP) in establishing and maintaining a safe and effective quality assurance (QA) program. The performance tests on a linear accelerator (linac) should be selected to fit the clinical patterns of use of the accelerator and care should be given to perform tests which are relevant to detecting errors related to the specific use of the accelerator. A risk assessment was performed on tests from current task group reports on linac QA to highlight those tests that are most effective at maintaining safety and quality for the patient. Recommendations are made on the acquisition of reference or baseline data, the establishment of machine isocenter on a routine basis, basing performance tests on clinical use of the linac, working with vendors to establish QA tests and performing tests after maintenance. The recommended tests proposed in this guideline were chosen based on the results from the risk analysis and the consensus of the guideline's committee. The tests are grouped together by class of test (e.g., dosimetry, mechanical, etc.) and clinical parameter tested. Implementation notes are included for each test so that the QMP can understand the overall goal of each test. This guideline will assist the QMP in developing a comprehensive QA program for linacs in the external beam radiation therapy setting. The committee sought to prioritize tests by their implication on quality and patient safety. The QMP is ultimately responsible for implementing appropriate tests. In the spirit of the report from American Association of Physicists in Medicine Task Group 100, individual institutions are encouraged to analyze the risks involved in their own clinical practice and determine which performance tests are relevant in their own radiotherapy clinics. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on

  3. "Know Your Status": results from a novel, student-run HIV testing initiative on college campuses.

    Science.gov (United States)

    Milligan, Caitlin; Cuneo, C Nicholas; Rutstein, Sarah E; Hicks, Charles

    2014-08-01

    Know Your Status (KYS), a novel, student-run program offered free HIV-testing at a private university (PU) and community college (CC). Following completion of surveys of risk behaviors/reasons for seeking testing, students were provided with rapid, oral HIV-testing. We investigated testing history, risk behaviors, and HIV prevalence among students tested during the first three years of KYS. In total, 1408 tests were conducted, 5 were positive: 4/408 CC, 1/1000 PU (1% vs. 0.1%, p=0.01). Three positives were new diagnoses, all black men-who-have-sex-with-men (MSM). Over 50% of students were tested for the first time and 59% reported risk behaviors. CC students were less likely to have used condoms at last sex (a surrogate for risk behavior) compared to PU (OR 0.73, CI [0.54, 0.98]). Race, sexual identity, and sex were not associated with condom use. These results demonstrate that KYS successfully recruited large numbers of previously untested, at-risk students, highlighting the feasibility and importance of testing college populations.

  4. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    /10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus...

  5. Validation of blood vitamin A concentrations in cattle: comparison of a new cow-side test (iCheck™ FLUORO) with high-performance liquid chromatography (HPLC).

    Science.gov (United States)

    Raila, Jens; Kawashima, Chiho; Sauerwein, Helga; Hülsmann, Nadine; Knorr, Christoph; Myamoto, Akio; Schweigert, Florian J

    2017-05-10

    Plasma concentration of retinol is an accepted indicator to assess the vitamin A (retinol) status in cattle. However, the determination of vitamin A requires a time consuming multi-step procedure, which needs specific equipment to perform extraction, centrifugation or saponification prior to high-performance liquid chromatography (HPLC). The concentrations of retinol in whole blood (n = 10), plasma (n = 132) and serum (n = 61) were measured by a new rapid cow-side test (iCheck™ FLUORO) and compared with those by HPLC in two independent laboratories in Germany (DE) and Japan (JP). Retinol concentrations in plasma ranged from 0.033 to 0.532 mg/L, and in serum from 0.043 to 0.360 mg/L (HPLC method). No significant differences in retinol levels were observed between the new rapid cow-side test and HPLC performed in different laboratories (HPLC vs. iCheck™ FLUORO: 0.320 ± 0.047 mg/L vs. 0.333 ± 0.044 mg/L, and 0.240 ± 0.096 mg/L vs. 0.241 ± 0.069 mg/L, lab DE and lab JP, respectively). A similar comparability was observed when whole blood was used (HPLC vs. iCheck™ FLUORO: 0.353 ± 0.084 mg/L vs. 0.341 ± 0.064 mg/L). Results showed a good agreement between both methods based on correlation coefficients of r 2  = 0.87 (P < 0.001) and Bland-Altman blots revealed no significant bias for all comparison. With the new rapid cow-side test (iCheck™ FLUORO) retinol concentrations in cattle can be reliably assessed within a few minutes and directly in the barn using even whole blood without the necessity of prior centrifugation. The ease of the application of the new rapid cow-side test and its portability can improve the diagnostic of vitamin A status and will help to control vitamin A supplementation in specific vitamin A feeding regimes such as used to optimize health status in calves or meat marbling in Japanese Black cattle.

  6. Report on long range alpha detector (LRAD) performance tests

    International Nuclear Information System (INIS)

    Kobayashi, Hirohide; Unno, Motoyoshi; Ishikawa, Hisashi; Yoshida, Tadayoshi

    2002-10-01

    At present, alpha contamination measurement on objects is conducted with ZnS scintillation survey meter (direct method) and smear test (indirect method). But it is difficult to measure large and complicated objects by direct method. Long Range Alpha Detector (LRAD) was produced as a solution for this problem. We carried out performance tests of this LRAD. As a result of the performance tests, we confirmed the linear relation between the measurement values of LRAD and alpha-radioactivity on the surface of objects. (author)

  7. On the Estimation of Disease Prevalence by Latent Class Models for Screening Studies Using Two Screening Tests with Categorical Disease Status Verified in Test Positives Only

    Science.gov (United States)

    Chu, Haitao; Zhou, Yijie; Cole, Stephen R.; Ibrahim, Joseph G.

    2010-01-01

    Summary To evaluate the probabilities of a disease state, ideally all subjects in a study should be diagnosed by a definitive diagnostic or gold standard test. However, since definitive diagnostic tests are often invasive and expensive, it is generally unethical to apply them to subjects whose screening tests are negative. In this article, we consider latent class models for screening studies with two imperfect binary diagnostic tests and a definitive categorical disease status measured only for those with at least one positive screening test. Specifically, we discuss a conditional independent and three homogeneous conditional dependent latent class models and assess the impact of misspecification of the dependence structure on the estimation of disease category probabilities using frequentist and Bayesian approaches. Interestingly, the three homogeneous dependent models can provide identical goodness-of-fit but substantively different estimates for a given study. However, the parametric form of the assumed dependence structure itself is not “testable” from the data, and thus the dependence structure modeling considered here can only be viewed as a sensitivity analysis concerning a more complicated non-identifiable model potentially involving heterogeneous dependence structure. Furthermore, we discuss Bayesian model averaging together with its limitations as an alternative way to partially address this particularly challenging problem. The methods are applied to two cancer screening studies, and simulations are conducted to evaluate the performance of these methods. In summary, further research is needed to reduce the impact of model misspecification on the estimation of disease prevalence in such settings. PMID:20191614

  8. The impact of educational level on performance on auditory processing tests

    Directory of Open Access Journals (Sweden)

    Cristina F.B. Murphy

    2016-03-01

    Full Text Available Research has demonstrated that a higher level of education is associated with better performance on cognitive tests among middle-aged and elderly people. However, the effects of education on auditory processing skills have not yet been evaluated. Previous demonstrations of sensory-cognitive interactions in the aging process indicate the potential importance of this topic. Therefore, the primary purpose of this study was to investigate the performance of middle-aged and elderly people with different levels of formal education on auditory processing tests. A total of 177 adults with no evidence of cognitive, psychological or neurological conditions took part in the research. The participants completed a series of auditory assessments, including dichotic digit, frequency pattern and speech-in-noise tests. A working memory test was also performed to investigate the extent to which auditory processing and cognitive performance were associated. The results demonstrated positive but weak correlations between years of schooling and performance on all of the tests applied. The factor years of schooling was also one of the best predictors of frequency pattern and speech-in-noise test performance. Additionally, performance on the working memory, frequency pattern and dichotic digit tests was also correlated, suggesting that the influence of educational level on auditory processing performance might be associated with the cognitive demand of the auditory processing tests rather than auditory sensory aspects itself. Longitudinal research is required to investigate the causal relationship between educational level and auditory processing skills.

  9. Fluid flow measurements of Test Series A and B for the Small Scale Seal Performance Tests

    International Nuclear Information System (INIS)

    Peterson, E.W.; Lagus, P.L.; Lie, K.

    1987-12-01

    The degree of waste isolation achieved by a repository seal system is dependent upon the fluid flow characteristics, or permeability, of the seals. In order to obtain meaningful, site-specific data on the performance of various possible seal system components, a series of in situ experiments called the Small Scale Seal Performance Tests (SSSPT) are being conducted at the Waste Isolation Pilot Plant (WIPP). This report contains the results of gas flow, tracer penetration, and brine flow tests conducted on concrete seals in vertical (Test Series A) and horizontal (Test Series B) configurations. The test objectives were to evaluate the seal performance and to determine if there existed scaling effects which could influence future SSSPT designs. 3 refs., 77 figs

  10. Radioactive material packaging performance testing

    International Nuclear Information System (INIS)

    Romano, T.

    1992-06-01

    In an effort to provide uniform packaging of hazardous material on an international level, recommendations for the transport of dangerous goods have been developed by the United Nations. These recommendations are performance oriented and contrast with a large number of packaging specifications in the US Department of Transportation's hazard materials regulations. This dual system presents problems when international shipments enter the US Department of Transportation's system. Faced with the question of continuing a dual system or aligning with the international system, the Research and Special Programs Administration of the US Department of Transportation responded with Docket HM-181. This began the transition toward the international transportation system. Following close behind is Docket HM-169A, which addressed low specific activity radioactive material packaging. This paper will discuss the differences between performance-oriented and specification packaging, the transition toward performance-oriented packaging by the US Department of Transportation, and performance-oriented testing of radioactive material packaging by Westinghouse Hanford Company. Dockets HM-181 and HM-169A will be discussed along with Type A (low activity) and Type B (high activity) radioactive material packaging evaluations

  11. RHIC sextant test: Accelerator systems and performance

    Energy Technology Data Exchange (ETDEWEB)

    Pilat, F.; Trbojevic, D.; Ahrens, L. [and others

    1997-08-01

    One sextant of the RHIC Collider was commissioned in early 1997 with beam. We describe here the performance of the accelerator systems, instrumentation subsystems and application software. We also describe a ramping test without beam that took place after the commissioning with beam. Finally, we analyze the implications of accelerator systems performance and their impact on the planning for RHIC installation and commissioning.

  12. RHIC sextant test: Accelerator systems and performance

    International Nuclear Information System (INIS)

    Pilat, F.; Trbojevic, D.; Ahrens, L.

    1997-01-01

    One sextant of the RHIC Collider was commissioned in early 1997 with beam. We describe here the performance of the accelerator systems, instrumentation subsystems and application software. We also describe a ramping test without beam that took place after the commissioning with beam. Finally, we analyze the implications of accelerator systems performance and their impact on the planning for RHIC installation and commissioning

  13. Liver Function Status in some Nigerian Children with Protein Energy ...

    African Journals Online (AJOL)

    Objective: To ascertain functional status of the liver in Nigeria Children with Protein energy malnutrition. Materials and Methods: Liver function tests were performed on a total of 88 children with protein energy malnutrition (PEM). These were compared with 22 apparently well-nourished children who served as controls.

  14. Influence of thermally peroxidized soybean oil on growth performance and oxidative status in growing pigs

    Science.gov (United States)

    The objective of this study was to evaluate the effect of feeding peroxidized soybean oil (SO) on growth performance and oxidative status in growing pigs. Fifty-six barrows (25.3 ± 3.3 kg initial BW) were randomly assigned to one of four diets containing either 10% fresh SO (22.5 C) or SO exposed to...

  15. Suspension tests on a larger scale. Report from the status seminar on magnetic suspension techniques. Testing of the electrodynamic system started

    Energy Technology Data Exchange (ETDEWEB)

    Rogg, D; Muckli, W

    1976-07-01

    A world record speed for electromagnetically suspended vehicles as well as successful suspension tests with forced-circulation cooled superconducting magnets were the outstanding success reports at the fifth status seminar 'Magnetic suspension techniques' on 31st March and 1st April in Bad Kissingen. The research work on magnetic suspension techniques in the railborne long-distance travel is supported by the Federal Ministry of Research and Technology (BMFT) within the frameworke of the programme 'Railway engineering - New technologies'.

  16. Performance test of a 1 MW class HTS synchronous motor for industrial application

    International Nuclear Information System (INIS)

    Kwon, Y.K.; Kim, H.M.; Baik, S.K.; Lee, E.Y.; Lee, J.D.; Kim, Y.C.; Lee, S.H.; Hong, J.P.; Jo, Y.S.; Ryu, K.S.

    2008-01-01

    This paper deals with development activities of high temperature superconducting (HTS) synchronous motor at DOOSAN heavy industry and Korea Electrotechnology Research Institute (KERI) in Korea, and is sponsored by DAPAS program which is supported by Korean government. The final aim of the project is realization of HTS motor in the field of industry such as large driving pumps, fans and compressors for utility and industrial environments. At present time, 1 MW HTS motor is developed for the purpose to fully represent the design and manufacturing issues for the larger capacity machine. The number of pole and rotating speed of machine are 2 pole and 3600 rpm. The HTS field coil of the developed motor is cooled by way of neon thermosyphon mechanism and the stator coil is cooled by water through hollow copper conductor. This paper describes status of 1 MW HTS motor development, such as design, fabrication and performance test results, which was conducted at steady state in generator mode and motor mode

  17. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    Science.gov (United States)

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  18. Human performance in nondestructive inspections and functional tests: Final report

    International Nuclear Information System (INIS)

    Harris, D.H.

    1988-10-01

    Human performance plays a vital role in the inspections and tests conducted to assure the physical integrity of nuclear power plants. Even when technically-sophisticated equipment is employed, the outcome is highly dependent on human control actions, calibrations, observations, analyses, and interpretations. The principal consequences of inadequate performance are missed or falsely-reported defects. However, the cost-avoidance that stems from addressing potential risks promptly, and the increasing costs likely with aging plants, emphasize that timeliness and efficiency are important inspection-performance considerations also. Human performance issues were studied in a sample of inspections and tests regularly conducted in nuclear power plants. These tasks, selected by an industry advisory panel, were: eddy-current inspection of steam-generator tubes; ultrasonic inspection of pipe welds; inservice testing of pumps and valves; and functional testing of shock suppressors. Information was obtained for the study from industry and plant procedural documents; training materials; research reports and related documents; interviews with training specialists, inspectors, supervisory personnel, and equipment designers; and first-hand observations of task performance. Eleven recommendations are developed for improving human performance on nondestructive inspections and functional tests. Two recommendations were for the more-effective application of existing knowledge; nine recommendations were for research projects that should be undertaken to assure continuing improvements in human performance on these tasks. 25 refs., 9 figs., 1 tab

  19. Testing the renormalisation group theory of cooperative transitions at the lambda point of helium

    Science.gov (United States)

    Lipa, J. A.; Li, Q.; Chui, T. C. P.; Marek, D.

    1988-01-01

    The status of high resolution tests of the renormalization group theory of cooperative phase transitions performed near the lambda point of helium is described. The prospects for performing improved tests in space are discussed.

  20. A performance-oriented and risk-based regulation for containment testing

    International Nuclear Information System (INIS)

    Dey, M.

    1994-01-01

    In August 1992, the NRC initiated a major initiative to develop requirements for containment testing that are less prescriptive, and more performance-oriented and risk-based. This action was a result of public comments and several studies that concluded that the economic burden of certain, present containment testing requirements are not commensurate with their safety benefits. The rulemaking will include consideration of relaxing the allowable containment leakage rate, increasing the interval for the integrated containment test, and establishing intervals for the local containment leak rate tests based on their performance. A study has been conducted to provide technical information for establishing the performance criteria for containment tests, the allowable leakage rate, commensurate with its significance to total public risk. The study used results of a recent comprehensive study conducted by the NRC, NUREG-1150, 'Severe Accident Risks: An Assessment for Five U.S. Nuclear Power Plants,' to examine the sensitivity of containment leakage to public risk. Risk was found to be insensitive to containment leakage rate up to levels of about 100 percent-volume per day for certain types of containments. PRA methods have also been developed to establish risk-based intervals for containment tests based on their past experience. Preliminary evaluations show that increasing the interval for the integrated containment leakage test from three times to once every ten years would have an insignificant impact on public risk. Preliminary analyses of operational experience data for local leak rate tests show that performance-based testing, valves and penetrations that perform well are tested less frequently, is feasible with marginal impact on safety. The above technical studies are being used to develop efficient (cost-effective) requirements for containment tests. (author). 4 refs., 2 figs

  1. Fabrication and irradiation testing of LEU [low enriched uranium] fuels at CRNL status as of 1987 September

    International Nuclear Information System (INIS)

    Sears, D.F.; Berthiaume, L.C.; Herbert, L.N.

    1987-01-01

    The current status of Chalk River Nuclear Laboratories' (CRNL) program to develop and test low-enriched uranium (LEU), proliferation-resistant fuels for use in research reactors is reviewed. CRNL's fuel manufacturing process has been qualified by the successful demonstration irradiation of 7 full-size rods in the NRU reactor. Now industrial-scale production equipment has been commissioned, and a fuel-fabrication campaign for 30 NRU rods and a MAPLE-X core is underway. Excess capacity could be used for commercial fuel fabrication. In the irradiation testing program, mini-elements with deliberately included core surface defects performed well in-reactor, swelling by only 7 to 8 vol% at 93 atomic percent burnup of the original U-235. The additional restraint provided by the aluminium cladding which flowed into the defects during extrusion contributed to this good performance. Mini-elements containing a variety of particle size distributions were also successfully irradiated to 93 at% burnup in NRU, as part of a study to establish the optimum particle size distribution. Swelling was found to be proportional to the percentage of fines (<44μm particles) contained in the cores. The mini-elements containing the composition normally used at CRNL had swollen by 5.8 vol%, and mini-elements with a much higher percentage of fines had swollen by 6.8 vol%, at 93 at% burnup. Also, a program to develop LEU targets for Mo-99 production, via the technology developed to fabricate dispersed silicide fuel, has started, and preliminary scoping studies are underway. (Author)

  2. Infant Nutritional Status, Feeding Practices, Enteropathogen Exposure, Socioeconomic Status, and Illness Are Associated with Gut Barrier Function As Assessed by the Lactulose Mannitol Test in the MAL-ED Birth Cohort.

    Science.gov (United States)

    Lee, Gwenyth O; McCormick, Benjamin J J; Seidman, Jessica C; Kosek, Margaret N; Haque, Rashidul; Olortegui, Maribel Paredes; Lima, Aldo A M; Bhutta, Zulfiqar A; Kang, Gagandeep; Samie, Amidou; Amour, Caroline; Mason, Carl J; Ahmed, Tahmeed; Yori, Pablo Peñataro; Oliveira, Domingos B; Alam, Didar; Babji, Sudhir; Bessong, Pascal; Mduma, Estomih; Shrestha, Sanjaya K; Ambikapathi, Ramya; Lang, Dennis R; Gottlieb, Michael; Guerrant, Richard L; Caulfield, Laura E; For The Mal-Ed Network Investigators

    2017-07-01

    The lactulose mannitol (LM) dual sugar permeability test is the most commonly used test of environmental enteropathy in developing countries. However, there is a large but conflicting literature on its association with enteric infection and host nutritional status. We conducted a longitudinal cohort using a single field protocol and comparable laboratory procedures to examine intestinal permeability in multiple, geographically diverse pediatric populations. Using a previously published systematic review to guide the selection of factors potentially associated with LM test results, we examined the relationships between these factors and mucosal breach, represented by percent lactulose excretion; absorptive area, represented by percent mannitol excretion; and gut barrier function, represented by the L/M ratio. A total of 6,602 LM tests were conducted in 1,980 children at 3, 6, 9, and 15 months old; percent lactulose excretion, percent mannitol excretion, and the L/M ratio were expressed as age- and sex-specific normalized values using the Brazil cohort as the reference population. Among the factors considered, recent severe diarrhea, lower socioeconomic status, and recent asymptomatic enteropathogen infections were associated with decreased percent mannitol excretion and higher L/M ratios. Poorer concurrent weight-for-age, infection, and recent breastfeeding were associated with increased percent lactulose excretion and increased L/M ratios. Our results support previously reported associations between the L/M ratio and factors related to child nutritional status and enteropathogen exposure. These results were remarkably consistent across sites and support the hypothesis that the frequency of these exposures in communities living in poverty leads to alterations in gut barrier function.

  3. Performances on Symbol Digit Modalities Test, Color Trails Test, and modified Stroop test in a healthy, elderly Danish sample

    DEFF Research Database (Denmark)

    Vogel, Asmus; Stokholm, Jette; Jørgensen, Kasper

    2013-01-01

    This study presents Danish data for the Symbol Digit Modalities Test (SDMT), Color Trails Test (CTT), and a modified Stroop test from 100 subjects aged 60-87 years. Among the included demographic variables, age had the highest impact on test performances. Thus, the study presents separate data...

  4. Contextual Influences on Children's Mental Health and School Performance: The Moderating Effects of Family Immigrant Status

    Science.gov (United States)

    Georgiades, Katholiki; Boyle, Michael H.; Duku, Eric

    2007-01-01

    Data from a nationally representative sample of 13,470 children aged 4-11 years were used to study contextual influences on children's mental health and school performance, the moderating effects of family immigrant status and underlying family processes that might explain these relationships. Despite greater socioeconomic disadvantage, children…

  5. Computer versus paper--does it make any difference in test performance?

    Science.gov (United States)

    Karay, Yassin; Schauber, Stefan K; Stosch, Christoph; Schüttpelz-Brauns, Katrin

    2015-01-01

    CONSTRUCT: In this study, we examine the differences in test performance between the paper-based and the computer-based version of the Berlin formative Progress Test. In this context it is the first study that allows controlling for students' prior performance. Computer-based tests make possible a more efficient examination procedure for test administration and review. Although university staff will benefit largely from computer-based tests, the question arises if computer-based tests influence students' test performance. A total of 266 German students from the 9th and 10th semester of medicine (comparable with the 4th-year North American medical school schedule) participated in the study (paper = 132, computer = 134). The allocation of the test format was conducted as a randomized matched-pair design in which students were first sorted according to their prior test results. The organizational procedure, the examination conditions, the room, and seating arrangements, as well as the order of questions and answers, were identical in both groups. The sociodemographic variables and pretest scores of both groups were comparable. The test results from the paper and computer versions did not differ. The groups remained within the allotted time, but students using the computer version (particularly the high performers) needed significantly less time to complete the test. In addition, we found significant differences in guessing behavior. Low performers using the computer version guess significantly more than low-performing students in the paper-pencil version. Participants in computer-based tests are not at a disadvantage in terms of their test results. The computer-based test required less processing time. The reason for the longer processing time when using the paper-pencil version might be due to the time needed to write the answer down, controlling for transferring the answer correctly. It is still not known why students using the computer version (particularly low-performing

  6. AEgIS Experiment: Status & Outlook

    CERN Document Server

    Lansonneur, P; Amsler, C; Bonomi, G; Brusa, R S; Caccia, M; Caravita, R; Castelli, F; Cerchiari, G; Comparat, D; Consolati, G; Demetrio, A; Di Noto, L; Doser, M; Evans, C; Ferragut, R; Fesel, J; Fontana, A; Gerber, S; Giammarchi, M; Gligorova, A; Guatieri, F; Haider, S; Hinterberger, A; Holmestad, H; Kellerbauer, A; Khalidova, O; Krasnicky, D; Lagomarsino, V; Lebrun, P; Malbrunot, C; Mariazzi, S; Marton, J; Matveev, V; Mazzotta, Z; Müller, S R; Nebbia, G; Nedelec, P; Oberthaler, M; Pacico, N; Pagano, D; Penasa, L; Petracek, V; Prelz, F; Prevedelli, M; Ravelli, L; Rienaecker, B; Robert, J; Rhøne, O M; Rotondi, A; Sacerdoti, M; Sandaker, H; Santoro, R; Simon, M; Smestad, L; Sorrentino, F; Testera, G; Tietje, I C; Widmann, E; Yzombard, P; Zimmer, C; Zmeska, J; Zurlo, N

    2017-01-01

    The AEGIS experiment 1 (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) is planned to perform the first measurement of the gravitational acceleration on antimatter by observing the free fall of antihydrogen atoms. By combining techniques based on recent developments in the production of positronium and its laser excitation to Rydberg states, such a study seems indeed to be feasible for neutral antimatter. We present here some of the experimental techniques involved in the experiment as well as the status of the detector test envisioned for the gravity measurement.

  7. THE EFFECTS OF INCOME, GENDER, AGE, EDUCATION, WORKING PERIOD, INSURANCE, TRAINING, AND WORKER STATUS ON OUTSOURCED AND WORKERS PERFORMANCE IN SOUTH SUMATERA IN MANUFACTURING COMPANIES

    Directory of Open Access Journals (Sweden)

    Ratna Juwita

    2017-06-01

    Full Text Available This research investigated the effects of income, gender, age, education, working period, insurance, training and workers’ status (outsourcing or permanent on performance. The result showed that gender, education, insurance, training and status had positive and significant effect on performace. Income had significant and negative effect on performance, the increased income would decrease performance. Age had positive but not significant effect, the increased age would decrease performance. Working period had negative but not significsnt effect on performance, the short working period would decrease performance.

  8. [Research progress on mechanical performance evaluation of artificial intervertebral disc].

    Science.gov (United States)

    Li, Rui; Wang, Song; Liao, Zhenhua; Liu, Weiqiang

    2018-03-01

    The mechanical properties of artificial intervertebral disc (AID) are related to long-term reliability of prosthesis. There are three testing methods involved in the mechanical performance evaluation of AID based on different tools: the testing method using mechanical simulator, in vitro specimen testing method and finite element analysis method. In this study, the testing standard, testing equipment and materials of AID were firstly introduced. Then, the present status of AID static mechanical properties test (static axial compression, static axial compression-shear), dynamic mechanical properties test (dynamic axial compression, dynamic axial compression-shear), creep and stress relaxation test, device pushout test, core pushout test, subsidence test, etc. were focused on. The experimental techniques using in vitro specimen testing method and testing results of available artificial discs were summarized. The experimental methods and research status of finite element analysis were also summarized. Finally, the research trends of AID mechanical performance evaluation were forecasted. The simulator, load, dynamic cycle, motion mode, specimen and test standard would be important research fields in the future.

  9. Performance testing of supercapacitors: Important issues and uncertainties

    Science.gov (United States)

    Zhao, Jingyuan; Gao, Yinghan; Burke, Andrew F.

    2017-09-01

    Supercapacitors are a promising technology for high power energy storage, which have been used in some industrial and vehicles applications. Hence, it is important that information concerning the performance of supercapacitors be detailed and reliable so system designers can make rational decisions regarding the selection of the energy storage components. This paper is concerned with important issues and uncertainties regarding the performance testing of supercapacitors. The effect of different test procedures on the measured characteristics of both commercial and prototype supercapacitors including hybrid supercapacitors have been studied. It was found that the test procedure has a relatively minor effect on the capacitance of carbon/carbon devices and a more significant effect on the capacitance of hybrid supercapacitors. The device characteristic with the greatest uncertainty is the resistance and subsequently the claimed power capability of the device. The energy density should be measured by performing constant power discharges between appropriate voltage limits. This is particularly important in the case of hybrid supercapacitors for which the energy density is rate dependent and the simple relationship E = ½CV2 does not yield accurate estimates of the energy stored. In general, most of the important issues for testing carbon/carbon devices become more serious for hybrid supercapacitors.

  10. Further examination of embedded performance validity indicators for the Conners' Continuous Performance Test and Brief Test of Attention in a large outpatient clinical sample.

    Science.gov (United States)

    Sharland, Michael J; Waring, Stephen C; Johnson, Brian P; Taran, Allise M; Rusin, Travis A; Pattock, Andrew M; Palcher, Jeanette A

    2018-01-01

    Assessing test performance validity is a standard clinical practice and although studies have examined the utility of cognitive/memory measures, few have examined attention measures as indicators of performance validity beyond the Reliable Digit Span. The current study further investigates the classification probability of embedded Performance Validity Tests (PVTs) within the Brief Test of Attention (BTA) and the Conners' Continuous Performance Test (CPT-II), in a large clinical sample. This was a retrospective study of 615 patients consecutively referred for comprehensive outpatient neuropsychological evaluation. Non-credible performance was defined two ways: failure on one or more PVTs and failure on two or more PVTs. Classification probability of the BTA and CPT-II into non-credible groups was assessed. Sensitivity, specificity, positive predictive value, and negative predictive value were derived to identify clinically relevant cut-off scores. When using failure on two or more PVTs as the indicator for non-credible responding compared to failure on one or more PVTs, highest classification probability, or area under the curve (AUC), was achieved by the BTA (AUC = .87 vs. .79). CPT-II Omission, Commission, and Total Errors exhibited higher classification probability as well. Overall, these findings corroborate previous findings, extending them to a large clinical sample. BTA and CPT-II are useful embedded performance validity indicators within a clinical battery but should not be used in isolation without other performance validity indicators.

  11. CASTOR-V/21 PWR spent fuel storage cask performance test

    International Nuclear Information System (INIS)

    Creer, J.M.; Schoonen, D.H.

    1986-01-01

    Performance testing of a CASTOR-V/21 PWR spent fuel storage cask manufactured by Gesellschaft fur Nuklear Service (GNS) was performed as part of a cooperative program between Virginia Power and the US Department of Energy. The performance test consisted of obtaining cask handling experience and heat transfer, shielding, and limited fuel integrity data. Five heat transfer test runs were performed with 21 Surry reactor spent fuel assemblies generating approximately 28 kW. Test runs were performed with vacuum, nitrogen, and helium backfills in both vertical and horizontal orientations. Cask exterior surface gamma and neutron dose rates were measured with the cask fully loaded. Gas samples were obtained at the beginning and end of each run with nitrogen or helium backfills to verify fuel integrity. The heat transfer performance of the CASTOR-V/21 cask was exceptionally good. Peak clad temperatures with helium and nitrogen backfills in a vertical orientation and with helium in a horizontal orientation were less than 380 0 C. Vertical vacuum and horizontal nitrogen runs resulted in peak clad temperatures over 380 0 , but the temperatures were not excessively high ( 0 C). The shielding performance of the cask met the design expectation of less than 200 mrem/h. Cask surface dose rates of <75 mrem/h can easily be established with minor gamma shielding design refinements if desired. Gas samples obtained during testing indicated no leaking fuel rods were present in the cask. It was concluded that the cask performed satisfactorily from heat transfer and shielding perspectives

  12. Student Performance and Family Socioeconomic Status: Results from a Survey of Compulsory Education in Western China

    Science.gov (United States)

    Liu, Xiaofei; Lu, Ke

    2008-01-01

    This study used fifteen-year-old ninth-grade students from rural areas of five provinces in western China as samples to carry out research on the relationship between the socioeconomic status of Chinese families and student academic performance. Based on parents' educational background, occupation, family economic conditions, and other factors,…

  13. QuantiFERON–TB Gold In-Tube test performance in Denmark

    DEFF Research Database (Denmark)

    Hermansen, Thomas; Lillebaek, Troels; Hansen, Ann-Brit E

    2014-01-01

    BACKGROUND: Little is known about the QuantiFERON-TB Gold In-Tube Test (QFT) in extreme age groups. The test performance has been reported to be impaired in children and elderly, but reports are diverging. The aim of this study was to evaluate QFT performance in patients with and without......, the overall QFT performance was good. The sensitivity in children (≥ 1) was high although few children were included, whereas sensitivity declined with increasing age. Indeterminate rates were higher in infants and elderly. In contrast to current guidelines, our data suggest that the QFT performs well...... in children ≥ 1 years in low endemic regions but that the test should be used with care among the elderly....

  14. Water electrolysis system refurbishment and testing

    Science.gov (United States)

    Greenough, B. M.

    1972-01-01

    The electrolytic oxygen generator for the back-up water electrolysis system in a 90-day manned test was refurbished, improved and subjected to a 182-day bench test. The performance of the system during the test demonstrated the soundness of the basic electrolysis concept, the high development status of the automatic controls which allowed completely hands-off operation, and the capability for orbital operation. Some design improvements are indicated.

  15. Eberline Alpha 7L Test Report

    CERN Document Server

    Chiaro, P J

    2002-01-01

    An Eberline continuous alpha air monitor model Alpha 7L was evaluated at Oak Ridge National Laboratory (ORNL) using the capabilities available at the Environmental Effects Laboratory (EELab). A series of tests were performed to ensure that procured units meet the requirements of the purchasing facility, Los Alamos National Laboratory (LANL). In addition to reporting on the results of each test, other activities were performed to reduce discovered susceptibilities. The parameters monitored during the tests typically included the airflow rate and/or net sup 2 sup 3 sup 9 Pu concentration values (pCi/liter). In addition, the spectrum display and operational status were monitored. Follow up tests were also performed on two LANL-provided production units. The results of those tests are at the end of this report.

  16. Performance Tests of a Mechanical Pump in Sodium Environment

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Kim, Byeongyeon; Cho, Youngil; Jung, Min-Hwan; Gam, Da-Young; Lee, Yong Bum; Jeong, Ji-Young; Kim, Jong-Bum [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Water is often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Nevertheless, to ensure the performance, safety, and operability of major components before its installation in the SFR, a series of demonstration experiments of some components in sodium environment should be positively necessary. So, SFR NSSS System Design Division of Korea Atomic Energy Research Institute (KAERI) built various sodium experimental facilities, especially STELLA-1 in 2012. STELLA-1 (Sodium inTegral Effect test Loop for safety simuLation and Assessment) is a large-scale separated effect test facility for demonstrating the thermal-hydraulic performances of major components such as a Sodium-to-Sodium heat exchanger (DHX), Sodium-to-Air heat exchanger (AHX) of the decay heat removal system, and mechanical sodium pump of the primary heat transport system (PHTS). The mechanical pump in-sodium performance test was successfully performed with good reproducibility of the experiment and data to compare hydraulic characteristic of a mechanical pump in-water was collected. In effect of temperature variation on the pump pressure head, reduction of pump pressure head at 250℃ by 0.57% of that of 300℃ maybe the result of an increase in sodium viscosity by 13.6% according to operating temperature decrease by 50℃. Also, we confirmed that the more flywheel weight, the longer halving time and the more initial flow rate when the pump seized, the shorter halving time. The results of the mechanical pump performance test data in sodium environment will be used to compare with that of the in water environment after the evaluation of measurement uncertainty for tests.

  17. Stereotype threat? Effects of inquiring about test takers' gender on conceptual test performance in physics

    Science.gov (United States)

    Maries, Alexandru; Singh, Chandralekha

    2015-12-01

    It has been found that activation of a stereotype, for example by indicating one's gender before a test, typically alters performance in a way consistent with the stereotype, an effect called "stereotype threat." On a standardized conceptual physics assessment, we found that asking test takers to indicate their gender right before taking the test did not deteriorate performance compared to an equivalent group who did not provide gender information. Although a statistically significant gender gap was present on the standardized test whether or not students indicated their gender, no gender gap was observed on the multiple-choice final exam students took, which included both quantitative and conceptual questions on similar topics.

  18. Performance norms for a rhesus monkey neuropsychological testing battery: acquisition and long-term performance.

    Science.gov (United States)

    Weed, M R; Taffe, M A; Polis, I; Roberts, A C; Robbins, T W; Koob, G F; Bloom, F E; Gold, L H

    1999-10-25

    A computerized behavioral battery based upon human neuropsychological tests (CANTAB, CeNeS, Cambridge, UK) has been developed to assess cognitive behaviors of rhesus monkeys. Monkeys reliably performed multiple tasks, providing long-term assessment of changes in a number of behaviors for a given animal. The overall goal of the test battery is to characterize changes in cognitive behaviors following central nervous system (CNS) manipulations. The battery addresses memory (delayed non-matching to sample, DNMS; spatial working memory, using a self-ordered spatial search task, SOSS), attention (intra-/extra-dimensional shift, ID/ED), motivation (progressive-ratio, PR), reaction time (RT) and motor coordination (bimanual task). As with human neuropsychological batteries, different tasks are thought to involve different neural substrates, and therefore performance profiles should assess function in particular brain regions. Monkeys were tested in transport cages, and responding on a touch sensitive computer monitor was maintained by food reinforcement. Parametric manipulations of several tasks demonstrated the sensitivity of performance to increases in task difficulty. Furthermore, the factors influencing difficulty for rhesus monkeys were the same as those shown to affect human performance. Data from this study represent performance of a population of healthy normal monkeys that will be used for comparison in subsequent studies of performance following CNS manipulations such as infection with simian immunodeficiency virus (NeuroAIDS) or drug administration.

  19. Performance demonstration experience for reactor pressure vessel shell ultrasonic testing

    International Nuclear Information System (INIS)

    Zado, V.

    1998-01-01

    The most ultrasonic testing techniques used by many vendors for pressurized water reactor (PWR) examinations were based on American Society of Mechanical Engineers 'Boiler and Pressurized Vessel Code' (ASME B and PV Code) Sections XI and V. The Addenda of ASME B and PV Code Section XI, Edition 1989 introduced Appendix VIII - 'Performance Demonstration for Ultrasonic Examination Systems'. In an effort to increase confidence in performance of ultrasonic testing of the operating nuclear power plants in United States, the ultrasonic testing performance demonstration examination of reactor vessel welds is performed in accordance with Performance Demonstration Initiative (PDI) program which is based on ASME Code Section XI, Appendix VIII requirements. This article provides information regarding extensive qualification preparation works performed prior EPRI guided performance demonstration exam of reactor vessel shell welds accomplished in January 1997 for the scope of Appendix VIII, Supplements IV and VI. Additionally, an overview of the procedures based on requirements of ASME Code Section XI and V in comparison to procedure prepared for Appendix VIII examination is given and discussed. The samples of ultrasonic signals obtained from artificial flaws implanted in vessel material are presented and results of ultrasonic testing are compared to actual flaw sizes. (author)

  20. Scope and status of the USA Engineering Test Facility including relevant TFTR research and development

    International Nuclear Information System (INIS)

    Becraft, W.R.; Reardon, P.J.

    1980-01-01

    The vehicle by which the fusion program would move into the engineering testing phase of fusion power development is designated the Engineering Test Facility (ETF). The progress toward the design and construction of the ETF will reflect the significant achievements of past, present, and future experimental tokamak devices. Some of the features of this foundation of experimental results and relevant engineering designs and operation will derive from the Tokamak Fusion Test Reactor (TFTR) Project, now nearing the completion of its construction phase. The ETF would provide a test-bed for reactor components in the fusion environment. In order to initiate preliminary planning for the ETF decision, the Office of Fusion Energy (OFE) established the ETF Design Center activity to prepare the design of the ETF. This paper describes the design status of the ETF and discusses some highlights of the TFTR R and D work

  1. Scope and status of the USA Engineering Test Facility including relevant TFTR research and development

    International Nuclear Information System (INIS)

    Becraft, W.R.; Reardon, P.J.

    1981-01-01

    The vehicle by which the fusion programme would move into the engineering testing phase of fusion power development is designated the Engineering Test Facility (ETF). The progress toward the design and construction of the ETF will reflect the significant achievements of past, present, and future experimental tokamak devices. Some of the features of this foundation of experimental results and relevant engineering designs and operation will derive from the Tokamak Fusion Test Reactor (TFTR) Project, now nearing the completion of its construction phase. The ETF would provide a test-bed for reactor components in the fusion environment. To initiate preliminary planning for the ETF decision, the Office of Fusion Energy (OFE) established the ETF Design Center activity to prepare the design of the ETF. This paper describes the design status of the ETF and discusses some highlights of the TFTR R and D work. (author)

  2. Status of the in-pile test of HCPB pebble-bed assemblies in the HFR Petten

    Energy Technology Data Exchange (ETDEWEB)

    Laan, J.G. van der; Fokkens, J.H.; Hofmans, H.E.; Jong, M.; Magielsen, A.J.; Pijlgroms, B.J.; Stijkel, M.P. [NRG, Petten (Netherlands); Conrad, R. [JRC, Inst. for Energy, Petten (Netherlands); Malang, S.; Reimann, J. [FZK, Karlsruhe (Germany); Roux, N. [CEA Saclay (France)

    2002-06-01

    In the framework of developing the helium cooled pebble-bed (HCPB) blanket an irradiation test of pebble-bed assemblies is prepared at the HFR Petten. The test objective is to concentrate on the effect of neutron irradiation on the thermal-mechanical behaviour of the HCPB breeder pebble-bed at DEMO representative levels of temperature and defined thermal-mechanical loads. The basic test elements are EUROFER-97 cylinders with a horizontal bed of ceramic breeder pebbles sandwiched between two beryllium beds. The pebble beds are separated by EUROFER-97 steel plates. The heat flow is managed such as to have a radial temperature distribution in the ceramic breeder pebble-bed as flat as reasonably possible. The paper reports on the project status, and presents the results of pre-tests, material characteristics, the manufacturing of the pebble-bed assemblies, and the nuclear and thermo-mechanical loading parameters. (orig.)

  3. Integrated Performance Testing for Nonproliferation Support Project

    Energy Technology Data Exchange (ETDEWEB)

    Johns, Russell; Bultz, Garl Alan; Byers, Kenneth R.; Yaegle, William

    2013-08-20

    The objective of this workshop is to provide participants with training in testing techniques and methodologies for assessment of the performance of: Physical Protection system elements; Material Control and Accounting (MC&A) system elements.

  4. Performance test results of mock-up test facility of HTTR hydrogen production system

    International Nuclear Information System (INIS)

    Ohashi, Hirofumi; Inaba, Yoshitomo; Nishihara, Tetsuo

    2004-01-01

    For the purpose to demonstrate effectiveness of high-temperature nuclear heat utilization, Japan Atomic Energy Research Institute has been developing a hydrogen production system and has planned to connect the hydrogen production system to High Temperature Engineering Test Reactor (HTTR). Prior to construction of a HTTR hydrogen production system, a mock-up test facility was constructed to investigate transient behavior of the hydrogen production system and to establish system controllability. The Mock-up test facility with a full-scale reaction tube is an approximately 1/30-scale model of the HTTR hydrogen production system and an electric heater is used as a heat source instead of a reactor. After its construction, a performance test of the test facility was carried out in the same pressure and temperature conditions as those of the HTTR hydrogen production system to investigate its performance such as hydrogen production ability, controllability and so on. It was confirmed that hydrogen was stably produced with a hot helium gas about 120m 3 /h, which satisfy the design value, and thermal disturbance of helium gas during the start-up could be mitigated within the design value by using a steam generator. The mock-up test of the HTTR hydrogen production system using this facility will continue until 2004. (author)

  5. 40 CFR 63.5992 - When must I conduct subsequent performance tests?

    Science.gov (United States)

    2010-07-01

    ... performance tests? 63.5992 Section 63.5992 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... CATEGORIES National Emissions Standards for Hazardous Air Pollutants: Rubber Tire Manufacturing General Testing and Initial Compliance Requirements § 63.5992 When must I conduct subsequent performance tests? If...

  6. Waste receiving and processing module 2A mixing tests status report

    International Nuclear Information System (INIS)

    Weber, J.R.; Hull, K.J.

    1994-01-01

    The purpose of this report is to document the Phase II test conditions, observations, and results of this work. This report provides additional mixing performance test data and rheologic data that provide further indications that there are clear and distinct advantages in the preliminary choice of high-shear mixing alone, and high-shear dispersion in combination with, or followed by, a low-speed type mixer/stirrer for WRAP 2A facility design. Another objective was to determine if significant scale-up problems might exist in the various mix and mixer designs. In the later Phase 2 tests the test material quantities were significantly larger than in the Phase 1 tests

  7. Honeywell Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Sargusingh, Miriam

    2014-01-01

    The ability to recover and purify water through physiochemical processes is crucial for realizing long-term human space missions, including both planetary habitation and space travel. Because of their robust nature, distillation systems have been actively pursued as one of the technologies for water recovery. The Cascade Distillation System (CDS) is a vacuum rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. The CDS was previously under development through Honeywell and NASA. In 2009, an assessment was performed to collect data to support down-selection and development of a primary distillation technology for application in a lunar outpost water recovery system. Based on the results of this testing, an expert panel concluded that the CDS showed adequate development maturity, TRL-4, together with the best product water quality and competitive weight and power estimates to warrant further development. The Advanced Exploration Systems (AES) Water Recovery Project (WRP) worked to address weaknesses identified by The Panel; namely bearing design and heat pump power efficiency. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades. The CDS will also have been challenged with ISS analog waste streams and a subset of those being considered for Exploration architectures. This paper details interim results of the AES WRP CDS performance testing.

  8. Performance and durability testing of parabolic trough receivers

    Science.gov (United States)

    Lei, Dongqiang; Fu, Xuqiang; Zhao, Dongming; Yuan, Guofeng; Wang, Zhifeng; Guo, Minghuan

    2017-06-01

    The paper describes the key performance and durability testing facilities of the parabolic trough receiver developed by Institute of Electrical Engineering, Chinese Academy of Sciences. The indoor heat loss test can be applied at 4-7 different temperature levels within 200-550 on receivers. The optical efficiency test bench consists of 12 metal halide lamps as the solar simulator and a 5 m length half-elliptical cylinder reflector with flat end reflectors. 3 ultra-precision temperature sensors are used in receiver each end to get the temperature difference. The residual gas analysis test bench is applied to analyze and predict the vacuum lifetime of the receiver. It can test the variations of composition and partial pressure of residual gases with temperature and time in the receiver annulus space by a high sensitivity quadrupole mass spectrometer gas analyzer. A coating accelerated ageing test bench, which is also used to test the thermal cycle, has been developed. This test bench uses the absorber tube of the recevier as the resistance heater to heat up the whole receiver. The coating lifetime can be predicted by the Arrhenius parameters. For the cycling test, the compressed air is used to directly cool the inner surface of the absorber tube. The thermal cycling test is performed with temperature cycles from 150 °C to 450 °C for 160 cycles. The maximum thermal cycling frequency is 8 cycles per day. The mechanical fatigue test bench is used to test the bellows and the glass-to-metal seals durability at the same time. Both bellows are expanded and compressed to 6.5 mm in turn with 10,000 cycles. A new rotating test bench was also developed to test the thermal efficiency of the receiver.

  9. THE EFFECTS OF INCOME, GENDER, AGE, EDUCATION, WORKING PERIOD, INSURANCE, TRAINING, AND WORKER STATUS ON OUTSOURCED AND WORKERS PERFORMANCE IN SOUTH SUMATERA IN MANUFACTURING COMPANIES

    OpenAIRE

    Ratna Juwita; Nurlina Tarmizi; Didik Susetyo; Bambang Bemby Soebyakto

    2017-01-01

    This research investigated the effects of income, gender, age, education, working period, insurance, training and workers’ status (outsourcing or permanent) on performance. The result showed that gender, education, insurance, training and status had positive and significant effect on performace. Income had significant and negative effect on performance, the increased income would decrease performance. Age had positive but not significant effect, the increased age would decrease...

  10. Clock face drawing test performance in children with ADHD.

    Science.gov (United States)

    Ghanizadeh, Ahmad; Safavi, Salar; Berk, Michael

    2013-01-01

    The utility and discriminatory pattern of the clock face drawing test in ADHD is unclear. This study therefore compared Clock Face Drawing test performance in children with ADHD and controls. 95 school children with ADHD and 191 other children were matched for gender ratio and age. ADHD symptoms severities were assessed using DSM-IV ADHD checklist and their intellectual functioning was assessed. The participants completed three clock-drawing tasks, and the following four functions were assessed: Contour score, Numbers score, Hands setting score, and Center score. All the subscales scores of the three clock drawing tests of the ADHD group were lower than that of the control group. In ADHD children, inattention and hyperactivity/ impulsivity scores were not related to free drawn clock test scores. When pre-drawn contour test was performed, inattentiveness score was statistically associated with Number score while none of the other variables of age, gender, intellectual functioning, and hand use preference were associated with that kind of score. In pre-drawn clock, no association of ADHD symptoms with any CDT subscales found significant. In addition, more errors are observed with free drawn clock and Pre-drawn contour than pre-drawn clock. Putting Numbers and Hands setting are more sensitive measures to screen ADHD than Contour and Center drawing. Test performance, except Hands setting, may have already reached a developmental plateau. It is probable that Hand setting deficit in children with ADHD may not decrease from age 8 to 14 years. Performance of children with ADHD is associated with complexity of CDT.

  11. Towards Smart Buildings Performance Testing as a Service

    DEFF Research Database (Denmark)

    Markoska, Elena; Lazarova-Molnar, Sanja

    2018-01-01

    Energy consumption in buildings accounts for ca. 40% of the world’s total energy consumption, yielding a call for attention to their performance and improvement of their behavior. The concept of performance testing has been developed as an approach to control, potentially lower, and bring awarene...

  12. The comparative performance of the single intradermal comparative tuberculin test in Irish cattle, using tuberculin PPD combinations from different manufacturers.

    Science.gov (United States)

    Good, M; Clegg, T A; Murphy, F; More, S J

    2011-07-05

    Ireland currently obtains its avian and bovine tuberculin purified protein derivatives (PPDs) from a single source. Because problems of supply or quality cannot be discounted, it is prudent that Ireland identify alternative supplier(s) as part of a broad risk management strategy. Therefore, the aim of this study was to compare the performance of a number of different tuberculin combinations (that is, pairings of bovine and avian PPD; with different manufacturers) in the single intradermal comparative tuberculin test (SICTT), as currently performed in Ireland. The study was randomised, controlled and double-blinded. A total of 2172 cattle were used in the study. Each animal was tested using two SICTTs, the first based on the tuberculin combination in current use, and the second using one of six trial tuberculin combinations. Analyses were conducted to compare both reactor-status and skin increase. For each control/trial tuberculin combination, there was good agreement between the control and trial reactor-status. Differences in skin increases were mainly confined to animals categorised as either negative or severe inconclusive. However, the measured differences were minor, and unlikely to have a significant impact on the actual test outcome, either for individual animals or for herds. In conclusion, while further studies determining sensitivity and specificity in Ireland would have to be done in the event of a change in tuberculin PPD there should be minimal disruption of the national programme if alternative tuberculin PPDs meeting WHO, OIE and EU regulations were used. In this study, the precision of the guinea pig bio-assay to assess tuberculin potency was low and therefore Ireland should maintain its practice of periodically assessing potency in naturally infected cattle, even though this is not currently required under WHO, OIE or EU Regulations. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Effects of preventive versus "on-demand" nutritional support on paid labour productivity, physical exercise and performance status during PEG-interferon-containing treatment for hepatitis C.

    Science.gov (United States)

    Huisman, Ellen J; van Meer, Suzanne; van Hoek, Bart; van Soest, Hanneke; van Nieuwkerk, Karin M J; Arends, Joop E; Siersema, Peter D; van Erpecum, Karel J

    2016-04-01

    Deterioration of nutritional status during PEG-interferon containing therapy for chronic hepatitis C can be ameliorated by preventive nutritional support. We aimed to explore whether such support also affects paid labour productivity, physical exercise and performance status. In this prospective randomized controlled trial (J Hepatol 2012;57:1069-75), 53 patients with chronic hepatitis C had been allocated to "on demand" support (n=26: nutritional intervention if weight loss>5%) or preventive support (n=27: regular dietary advice plus energy- and protein-rich evening snack) during PEG-interferon-containing therapy. Paid labour productivity, physical exercise and performance status were evaluated at baseline, after 24 and (if applicable) after 48 weeks of treatment. At baseline, 46% of patients performed paid labour and 62% performed some kind of physical exercise. Furthermore, most patients were able to carry out normal activity with only minor symptoms of disease (mean Karnofsky performance score: 94). Decreases of paid labour productivity (-21% vs. -70%, P=0.003), physical exercise activity (-43% vs. -87%, P=0.005) and Karnofsky performance scores (-12% vs. -24%, Plabour productivity, physical exercise and performance status during PEG-interferon-containing treatment for chronic hepatitis C. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  14. NEPTUN/5052, PWR LOCA Cooling Heat Transfer Tests for Loft, Reflood Test

    International Nuclear Information System (INIS)

    Richner, M.; Analytis, G.Th.; Aksan, S.N.

    1993-01-01

    1 - Description of test facility: NEPTUN is designed to perform PWR LOCA simulation experiments, which provide the full length emergency cooling heat transfer tests for LOFT. Therefore the NEPTUN heater bundle with 33 electrical heater elements and 4 guide tubes simulates a section of the LOFT nuclear core. The main test loop also contains measuring systems for the carry-over rate and for the steam expelled, and a back-pressure control system. A water loop brings the water to the initial reflooding conditions. In addition, auxiliary systems maintain normal operating conditions. 2 - Description of test: Test 5052 is one of a series of 40 reflood tests performed in NEPTUN. Before the start of the test, the flooding water in its circuit is brought to the following conditions: pressure = 4.1 bar; velocity = 2.5 cm/sec; subcooling temperature = 78 C; single rod power = 2.45 kW; maximal initial cladding temperature = 867 C. 3 - Status: CSNI1013/01, 21-Jul-1993 Arrived at NEADB

  15. Evaluation of Asphalt Mixture Low-Temperature Performance in Bending Beam Creep Test.

    Science.gov (United States)

    Pszczola, Marek; Jaczewski, Mariusz; Rys, Dawid; Jaskula, Piotr; Szydlowski, Cezary

    2018-01-10

    Low-temperature cracking is one of the most common road pavement distress types in Poland. While bitumen performance can be evaluated in detail using bending beam rheometer (BBR) or dynamic shear rheometer (DSR) tests, none of the normalized test methods gives a comprehensive representation of low-temperature performance of the asphalt mixtures. This article presents the Bending Beam Creep test performed at temperatures from -20 °C to +10 °C in order to evaluate the low-temperature performance of asphalt mixtures. Both validation of the method and its utilization for the assessment of eight types of wearing courses commonly used in Poland were described. The performed test indicated that the source of bitumen and its production process (and not necessarily only bitumen penetration) had a significant impact on the low-temperature performance of the asphalt mixtures, comparable to the impact of binder modification (neat, polymer-modified, highly modified) and the aggregate skeleton used in the mixture (Stone Mastic Asphalt (SMA) vs. Asphalt Concrete (AC)). Obtained Bending Beam Creep test results were compared with the BBR bitumen test. Regression analysis confirmed that performing solely bitumen tests is insufficient for comprehensive low-temperature performance analysis.

  16. The performance test of NAA laboratory at radionuclide measure with low activity

    International Nuclear Information System (INIS)

    Sri Murniasih; Sukirno

    2016-01-01

    The performance test to measure the I-131 radionuclide activity has been carried out at CAST-NAA laboratory. The purpose of this activity is to know the performance of a laboratory in the testing of low radioactivity sample. The tested sample consists of the form I-131 radionuclide sources shaped thin plastic disk with a certain weight. Evaluation of laboratory performance test results carried out by the organizer of the program test appeal (PTKMR-BATAN). Evaluation results showed that testing of point source of the I-131 radionuclide with comparative method gives a good enough results with errors below 10%. The results of the performance test evaluation are useful as the external quality control to a testing method that is expected in NAA laboratory. (author)

  17. Functional Performance and Associations between Performance Tests and Neurological Assessment Differ in Men and Women with Parkinson's Disease.

    Science.gov (United States)

    Medijainen, Kadri; Pääsuke, Mati; Lukmann, Aet; Taba, Pille

    2015-01-01

    Neurological assessment of a patient with Parkinson's disease (PD) is expected to reflect upon functional performance. As women are known to report more limitations even for same observed functional performance level, present study was designed to examine whether associations between neurological assessments and functional performance differ across genders. 14 men and 14 women with PD participated. Functional performance was assessed by measuring walking speeds on 10-meter walk test (10MWT) and by performing timed-up-and-go-test (TUG). Neurological assessment included Hoehn and Yahr Scale (HY), Movement Disorders Society Unified Parkinson's Disease Rating Scale (MDS-UPDRS), Schwab and England Activities of Daily Living Scale (S-E), and Mini Mental State Examination (MMSE). In women with PD, Kendall's tau-b correlation analyses revealed significant correlations between functional performance tests and neurological assessment measures, with the exception in MMSE. No corresponding associations were found for men, although they demonstrated better functional performance, as expected. Men in similar clinical stage of the PD perform better on functional tests than women. Disease severity reflects upon functional performance differently in men and women with PD. Results indicate that when interpreting the assessment results of both functional performance and neurological assessment tests, the gender of the patient should be taken into consideration.

  18. Predicting employment status and subjective quality of life in patients with schizophrenia

    Directory of Open Access Journals (Sweden)

    Haruo Fujino

    2016-03-01

    Full Text Available Although impaired social functioning, particularly poor employment status, is a cardinal feature of patients with schizophrenia and leads to decreased quality of life (QOL, few studies have addressed the relationship between these two clinical issues. The aim of this study was to determine whether employment status predicts subjective QOL and to evaluate a model in which functional capacity mediates the relationship between general cognitive performance and employment status. Ninety-three patients with schizophrenia were administered a comprehensive battery of cognitive tests, the UCSD Performance-based Skills Assessment-Brief version (UPSA-B, the Social Functioning Scale (SFS, and the Subjective Quality of Life Scale (SQLS. First, we evaluated a model for predicting the employment/occupation subscale score of the SFS using path analysis, and the model fitted well (χ2 (4 = 3.6, p = 0.46; CFI = 1.0; RMSEA < 0.001, with 90% CIs: 0–0.152. Employment status was predicted by negative symptoms and functional capacity, which was in turn predicted by general cognitive performance. Second, we added subjective QOL to this model. In a final path model, QOL was predicted by negative symptoms and employment status. This model also satisfied good fit criteria (χ2 (7 = 10.3, p = 0.17; CFI = 0.987; RMSEA = 0.072, with 90% CIs: 0–0.159. The UPSA-B and SFS scores were moderately correlated with most measures of cognitive performance. These results support the notion that better employment status enhances subjective QOL in patients with schizophrenia.

  19. Rheological Method for Alpha Test Evaluation of Developing Superplasticizers’ Performance: Channel Flow Test

    Directory of Open Access Journals (Sweden)

    Jae Hong Kim

    2017-01-01

    Full Text Available Advance in high-range water-reducing admixture revolutionizes the workability and constructability of conventional vibrated concrete as well as self-consolidating concrete. Its need from construction fields has increased, and consequently a variety of new-type polycarboxylates, base polymers for the admixture, are being formulated in these days. Synthesizing new polymers needs a quick, but reliable, test to evaluate its performance on concrete. The test is also asked for selecting the best applicable brand of them before a test concrete will be mixed. This paper proposes a “channel flow test” and its usage for the purpose. The proposed procedure for the test includes the mix proportion of a test mortar, the test method, and rheological interpretation of the test results.

  20. Improvement in performance status after erythropoietin treatment in lung cancer patients undergoing concurrent chemoradiotherapy

    International Nuclear Information System (INIS)

    Casas, Francesc; Vinolas, Nuria; Ferrer, Ferran; Farrus, Blanca; Gimferrer, Josep Maria; Agusti, Carles; Belda, Josep; Luburich, Patricio

    2003-01-01

    Purpose: A prospective Phase II trial was carried out to evaluate the effectiveness of erythropoietin in improving or maintaining performance status as determined by the Karnofsky performance status (KPS) score and hemoglobin (Hb) levels in lung cancer patients treated with concurrent chemoradiation (CH-RT). Methods and Materials: A total of 51 patients with lung cancer (11 with small-cell, limited stage and 40 with non-small-cell disease, 17 with Stage IIIA and 23 with Stage IIIB), who underwent three different concurrent CH-RT protocols were enrolled. Baseline Hb and KPS values were recorded, as were the nadir Hb and KPS values before concurrent CH-RT. The final Hb and KPS values were recorded the last week of concurrent CH-RT. An Hb level of ≤11 g/dL before concurrent CH-RT was required before receiving erythropoietin. Prognostic factors for KPS improvement and survival were assessed by univariate and multivariate studies. Results: Of the 51 patients, 47 (92.3%) were men (mean age 63.6 years, range 40-75). The median baseline KPS score was 80, and the mean baseline Hb was 12.2 ± 1.76 g/dL (range 9-16.9). The mean nadir and final Hb value was 9.98±0.67 g/dL (range 8.6-11) and 11.33±1.59 g/dL (range 6.9-14.4), respectively. A significant increase was seen in the Hb and KPS score (p<0.05) in the final measurements. Differences were found between the final and nadir Hb in the predictive value for differences in performance status (p=0.001). On univariate study, pathologic findings (p=0.0234), weight loss (p=0.0049), baseline Hb (p=0.0057), and final Hb improvement (p=0.0237) were prognostic factors for survival. Nadir Hb (p=0.027), final Hb improvement (p=0.0069), pathologic findings (p = 0.0006), and weight loss (p=0.0001) had significant prognostic value for survival in multivariate analysis. Conclusion: In this study, erythropoietin appears to have a significant, beneficial impact on the KPS and Hb of patients undergoing concurrent CH-RT

  1. The impact of physical performance and cognitive status on subsequent ADL disability in low-functioning older adults

    NARCIS (Netherlands)

    Kempen, GIJM; Ormel, J

    Objectives. The purpose of this study was to examine the independent contributions of physical performance and cognitive status to subsequent levels of ADL disability in low-functioning non-institutionalized older adults. Methods. A prospective cohort study included 416 women and 141 men 57 years of

  2. Parental Socioeconomic Status, Communication, and Children's Vocabulary Development: A Third-Generation Test of the Family Investment Model

    Science.gov (United States)

    Sohr-Preston, Sara L.; Scaramella, Laura V.; Martin, Monica J.; Neppl, Tricia K.; Ontai, Lenna; Conger, Rand

    2013-01-01

    This third-generation, longitudinal study evaluated a family investment perspective on family socioeconomic status (SES), parental investments in children, and child development. The theoretical framework was tested for first-generation parents (G1), their children (G2), and the children of the second generation (G3). G1 SES was expected to…

  3. Mediation and Moderation: Testing Relationships between Symptom Status, Functional Health, and Quality of Life in HIV Patients

    Science.gov (United States)

    Ryu, Ehri; West, Stephen G.; Sousa, Karen H.

    2009-01-01

    We extended Wilson and Cleary's (1995) health-related quality of life model to examine the relationships among symptom status (Symptoms), functional health (Disability), and quality of life (QOL). Using a community sample (N = 956) of male HIV positive patients, we tested a mediation model in which the relationship between Symptoms and QOL is…

  4. Automated Non-Destructive Testing Array Evaluation System

    Energy Technology Data Exchange (ETDEWEB)

    Wei, T.; Zavaljevski, N.; Bakhtiari, S.; Miron, A.; Jupperman, D.

    2004-12-31

    Utilities perform eddy current tests on nuclear power plant steam generator (SG) tubes to detect degradation. This report summarizes the status of ongoing research to develop signal processing algorithms that automate analysis of eddy current test data. The research focuses on analyzing array probe data for detecting, classifying, and characterizing degradation in SG tubes.

  5. Automated Non-Destructive Testing Array Evaluation System

    International Nuclear Information System (INIS)

    Wei, T.; Zavaljevski, N.; Bakhtiari, S.; Miron, A.; Kupperman, D.

    2004-01-01

    Utilities perform eddy current tests on nuclear power plant steam generator (SG) tubes to detect degradation. This report summarizes the status of ongoing research to develop signal processing algorithms that automate analysis of eddy current test data. The research focuses on analyzing array probe data for detecting, classifying, and characterizing degradation in SG tubes

  6. Gamma-ray shielding design and performance test of WASTEF

    International Nuclear Information System (INIS)

    Matsumoto, Seiichiro; Aoyama, Saburo; Tashiro, Shingo; Nagai, Shiro

    1984-06-01

    The Waste Safety Testing Facility (WASTEF) was planned in 1978 to test the safety performance of HLW vitrified forms under the simulated conditions of long term storage and disposal, and completed in August 1981. The designed feature of the facility is to treat the vitrified forms contain actual high-level wastes of 5 x 10 4 Ci in maximum with 5 units of concrete shilded hot cells (3 units : Bate-Gamma cells, 2 units : Alpha-Gamma cells) and one units of Alpha-Gamma lead shielded cell, and to store radioactivity of 10 6 Ci in maximum. The safety performance of this facility is fundamentally maintained with confinement of radioactivity and shielding of the radiation. This report describes the method of gamma-ray shielding design, evaluation of the shielding test performed by using sealded gamma-ray sources(Co-60). (author)

  7. Testing the status-legitimacy hypothesis: A multilevel modeling approach to the perception of legitimacy in income distribution in 36 nations.

    Science.gov (United States)

    Caricati, Luca

    2017-01-01

    The status-legitimacy hypothesis was tested by analyzing cross-national data about social inequality. Several indicators were used as indexes of social advantage: social class, personal income, and self-position in the social hierarchy. Moreover, inequality and freedom in nations, as indexed by Gini and by the human freedom index, were considered. Results from 36 nations worldwide showed no support for the status-legitimacy hypothesis. The perception that income distribution was fair tended to increase as social advantage increased. Moreover, national context increased the difference between advantaged and disadvantaged people in the perception of social fairness: Contrary to the status-legitimacy hypothesis, disadvantaged people were more likely than advantaged people to perceive income distribution as too large, and this difference increased in nations with greater freedom and equality. The implications for the status-legitimacy hypothesis are discussed.

  8. The effect of breed type and lactation status on reproductive performance in Awassi ewes

    OpenAIRE

    Kridli, R.T.; Abdullah, A.Y.; Husein, M.Q.

    2009-01-01

    This study was conducted to evaluate the effect of breed types and lactation status on reproductive performance of hormonally-treated Awassi ewes. A total of 282 ewes were treated with intravaginal progestagen sponges and equine chorionic gonadotropin. Ewes were mated with fertile rams following sponge removal. Lambing rate was similar between brown-and black-faced ewes, while the percentage of multiple births, fecundity and prolificacy were greater in black-faced ewes. Lambing rate and the p...

  9. Functional Task Test: 3. Skeletal Muscle Performance Adaptations to Space Flight

    Science.gov (United States)

    Ryder, Jeffrey W.; Wickwire, P. J.; Buxton, R. E.; Bloomberg, J. J.; Ploutz-Snyder, L.

    2011-01-01

    The functional task test is a multi-disciplinary study investigating how space-flight induced changes to physiological systems impacts functional task performance. Impairment of neuromuscular function would be expected to negatively affect functional performance of crewmembers following exposure to microgravity. This presentation reports the results for muscle performance testing in crewmembers. Functional task performance will be presented in the abstract "Functional Task Test 1: sensory motor adaptations associated with postflight alternations in astronaut functional task performance." METHODS: Muscle performance measures were obtained in crewmembers before and after short-duration space flight aboard the Space Shuttle and long-duration International Space Station (ISS) missions. The battery of muscle performance tests included leg press and bench press measures of isometric force, isotonic power and total work. Knee extension was used for the measurement of central activation and maximal isometric force. Upper and lower body force steadiness control were measured on the bench press and knee extension machine, respectively. Tests were implemented 60 and 30 days before launch, on landing day (Shuttle crew only), and 6, 10 and 30 days after landing. Seven Space Shuttle crew and four ISS crew have completed the muscle performance testing to date. RESULTS: Preliminary results for Space Shuttle crew reveal significant reductions in the leg press performance metrics of maximal isometric force, power and total work on R+0 (pperformance metrics were observed in returning Shuttle crew and these adaptations are likely contributors to impaired functional tasks that are ambulatory in nature (See abstract Functional Task Test: 1). Interestingly, no significant changes in central activation capacity were detected. Therefore, impairments in muscle function in response to short-duration space flight are likely myocellular rather than neuromotor in nature.

  10. 42 CFR 84.103 - Man tests; performance requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests; performance requirements. 84.103 Section 84.103 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.103 Man tests;...

  11. Measurement properties of continuous text reading performance tests.

    Science.gov (United States)

    Brussee, Tamara; van Nispen, Ruth M A; van Rens, Ger H M B

    2014-11-01

    Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. A literature search was performed in PubMed, Embase and PsycInfo. Subsequently, information on design and content of reading tests, study design and measurement properties were extracted using consensus-based standards for selection of health measurement instruments. Quality of studies, reading tests and measurement properties were systematically assessed using pre-specified criteria. From 2334 identified articles, 20 relevant articles were found on measurement properties of three reading tests in various languages: IReST, MNread Reading Test and Radner Reading Charts. All three reading tests scored high on content validity. Reproducibility studies (repeated measurements between different testing sessions) of the IReST and MNread of commercially available reading tests in different languages were missing. The IReST scored best on inter-language comparison, the MNread scored well in repeatability studies (repeated measurements under the same conditions) and the Radner showed good reproducibility in studies. Although in daily practice there are other continuous text reading tests available meeting the criteria of this review, measurement properties were described in scientific studies for only three of them. Of the few available studies, the quality and content of study design and methodology used varied. For testing existing reading tests and the development of new ones, for example in other languages, we make several recommendations, including careful description of patient characteristics, use of objective and subjective lighting levels, good control of working distance, documentation of the number of raters and their training, careful documentation of scoring rules and the use of Bland-Altman analyses or similar for

  12. Test Takers' Performance Appraisals, Appraisal Calibration, and Cognitive and Metacognitive Strategy Use

    Science.gov (United States)

    Phakiti, Aek

    2016-01-01

    The current study explores the nature and relationships among test takers' performance appraisals, appraisal calibration, and reported cognitive and metacognitive strategy use in a language test situation. Performance appraisals are executive processes of strategic competence for judging test performance (e.g., evaluating the correctness or…

  13. Multiphase pumping: indoor performance test and oilfield application

    Science.gov (United States)

    Kong, Xiangling; Zhu, Hongwu; Zhang, Shousen; Li, Jifeng

    2010-03-01

    Multiphase pumping is essentially a means of adding energy to the unprocessed effluent which enables the liquid and gas mixture to be transported over a long distances without prior separation. A reduction, consolidation, or elimination of the production infrastructure, such as separation equipments and offshore platforms can be developed more economically. Also it successfully lowed the backpressure of wells, revived dead wells and improved the production and efficiency of oilfield. This paper reviews the issues related to indoor performance test and an oilfield application of the helico-axial multiphase pump designed by China University of Petroleum (Beijing). Pump specification and its hydraulic design are given. Results of performance testing under different condition, such as operational speed and gas volume fraction (GVF) etc are presented. Experimental studies on combination of theoretical analysis showed the multiphase pump satisfies the similitude rule, which can be used in the development of new MPP design and performance prediction. Test results showed that rising the rotation speed and suction pressure could better its performance, pressure boost improved, high efficiency zone expanding and the flow rate related to the optimum working condition increased. The pump worked unstable as GVF increased to a certain extent and slip occurred between two phases in the pump, creating surging and gas lock at a high GVF. A case of application in Nanyang oilfield is also studied.

  14. Prevalence of upper gastrointestinal symptoms and their influence on nutritional state and performance status in patients with different primary tumors receiving palliative care.

    Science.gov (United States)

    Bovio, Giacomo; Fonte, Maria Luisa; Baiardi, Paola

    2014-02-01

    The aim of this study was to investigate the relationship between gastrointestinal symptoms, nutritional balance, and performance status in patients receiving palliative care for advanced cancers originating in different sites. We studied a total of 105 patients. Upper gastrointestinal symptoms, Eastern Cooperative Oncology Group Performance Status score (ECOG-PS), dietary intakes, anthropometric measures, and some serum proteins were determined. Unintentional weight loss, alterations in anthropometric measures, and highest number of symptoms were greater in patients with lung and stomach cancer. No differences were found in ECOG-PS according to cancer site. Patients with gastric or lung cancer have most evidence of protein-calorie malnutrition and a higher prevalence of upper gastrointestinal symptoms. The performance status is not affected by tumor site. Early nutritional support should be planned for all patients with cancer, especially for patients with gastric or lung cancer.

  15. Performance-intensity functions of Mandarin word recognition tests in noise: test dialect and listener language effects.

    Science.gov (United States)

    Liu, Danzheng; Shi, Lu-Feng

    2013-06-01

    This study established the performance-intensity function for Beijing and Taiwan Mandarin bisyllabic word recognition tests in noise in native speakers of Wu Chinese. Effects of the test dialect and listeners' first language on psychometric variables (i.e., slope and 50%-correct threshold) were analyzed. Thirty-two normal-hearing Wu-speaking adults who used Mandarin since early childhood were compared to 16 native Mandarin-speaking adults. Both Beijing and Taiwan bisyllabic word recognition tests were presented at 8 signal-to-noise ratios (SNRs) in 4-dB steps (-12 dB to +16 dB). At each SNR, a half list (25 words) was presented in speech-spectrum noise to listeners' right ear. The order of the test, SNR, and half list was randomized across listeners. Listeners responded orally and in writing. Overall, the Wu-speaking listeners performed comparably to the Mandarin-speaking listeners on both tests. Compared to the Taiwan test, the Beijing test yielded a significantly lower threshold for both the Mandarin- and Wu-speaking listeners, as well as a significantly steeper slope for the Wu-speaking listeners. Both Mandarin tests can be used to evaluate Wu-speaking listeners. Of the 2, the Taiwan Mandarin test results in more comparable functions across listener groups. Differences in the performance-intensity function between listener groups and between tests indicate a first language and dialectal effect, respectively.

  16. Status report of PEP-4

    International Nuclear Information System (INIS)

    Kamae, Tuneyoshi

    1982-01-01

    The present status of PEP-4 is reported. The cosmic ray test of a TPC without magnetic field was done in July, 1981, and tracks were observed on the first day of the test. The entire PEP-4 detector was tested with 3.9 kG magnetic field in November, 1981, and various trigger configurations were tested. The TPC performed well during the test, and a preliminary analysis gave an encouraging position resolution which is expected to be improved with the correction for various non-uniformity and by refining the fitting procedure. Furthermore, the detection efficiency of the muon chamber was about 99 %. In November and December, 1981, the cosmic ray test of the hexagonal calorimeter was carried out. The performance was just as expected. Noise did not pose any problem, and the peak of the Fourier coefficient gave a nice overall calibration of the calorimeter. There are some problems to be solved in future. With the TPC, the impurities in the gas, the electronic noise, the hooks and the magnetic coil should be improved. In addition, there are some problems with the inner drift chamber, the hexagonal calorimeter and the relativistic rise measured by the TPC. The very recent results with the first e + e - beam obtained in February, 1982, are briefly reported, although the events have not been fully analyzed. (Ito, K.)

  17. Performance Tests for Bubble Blockage Device

    International Nuclear Information System (INIS)

    Ha, Kwang Soon; Wi, Kyung Jin; Park, Rae Joon; Wan, Han Seong

    2014-01-01

    Postulated severe core damage accidents have a high threat risk for the safety of human health and jeopardize the environment. Versatile measures have been suggested and applied to mitigate severe accidents in nuclear power plants. To improve the thermal margin for the severe accident measures in high-power reactors, engineered corium cooling systems involving boiling-induced two-phase natural circulation have been proposed for decay heat removal. A boiling-induced natural circulation flow is generated in a coolant path between a hot vessel wall and cold coolant reservoir. In general, it is possible for some bubbles to be entrained in the natural circulation loop. If some bubbles entrain in the liquid phase flow passage, flow instability may occur, that is, the natural circulation mass flow rate may be oscillated. A new device to block the entraining bubbles is proposed and verified using air-water test loop. To avoid bubbles entrained in the natural circulation flow loop, a new device was proposed and verified using an air-water test loop. The air injection and liquid circulation loop was prepared, and the tests for the bubble blockage devices were performed by varying the geometry and shape of the devices. The performance of the bubble blockage device was more effective as the area ratio of the inlet to the down-comer increased, and the device height decreased. If the device has a rim to generate a vortex zone, the bubbles will be most effectively blocked

  18. Clock Face Drawing Test Performance in Children with ADHD

    Directory of Open Access Journals (Sweden)

    Ahmad Ghanizadeh

    2013-01-01

    Full Text Available  Introduction: The utility and discriminatory pattern of the clock face drawing test in ADHD is unclear. This study therefore compared Clock Face Drawing test performance in children with ADHD and controls.   Material & methods: 95 children with ADHD and 191 school children were matched for gender ratio and age. ADHD symptoms severities were assessed using DSM-IV ADHD checklist and their intellectual functioning was assessed. The participants completed three clock-drawing tasks, and the following four functions were assessed: Contour score, Numbers score, Hands setting score, and Center score    Results: All the subscales scores of the three clock drawing tests of the ADHD group were lower than that of the control group. In ADHD children, inattention and hyperactivity/impulsivity scores were not related with free drawn clock test scores. When pre-drawn contour test was performed, inattentiveness score was statistically associated with Number score. None of the other variables of age, gender, intellectual functioning, and hand use preference were associated with Numbers score. In pre-drawn clock, no association of ADHD symptoms with any CDT subscales was significant. In addition, more errors are observed with free drawn clock and Pre-drawn contour than pre-drawn clock.    Conclusion: Putting Numbers and Hands setting are more sensitive measures to screen ADHD than Contour and Center drawing. Test performance, except Hands setting, may have already reached a developmental plateau. It is probable that Hand setting deficit in children with ADHD may not decrease from age 8 to 14 years. Performance of children with ADHD is associated with the complexity of CDT.

  19. The comparative performance of the single intradermal test and the single intradermal comparative tuberculin test in Irish cattle, using tuberculin PPD combinations of differing potencies.

    Science.gov (United States)

    Good, M; Clegg, T A; Costello, E; More, S J

    2011-11-01

    In national bovine tuberculosis (BTB) control programmes, testing is generally conducted using a single source of bovine purified protein derivative (PPD) tuberculin. Alternative tuberculin sources should be identified as part of a broad risk management strategy as problems of supply or quality cannot be discounted. This study was conducted to compare the impact of different potencies of a single bovine PPD tuberculin on the field performance of the single intradermal comparative tuberculin test (SICTT) and single intradermal test (SIT). Three trial potencies of bovine PPD tuberculin, as assayed in naturally infected bovines, namely, low (1192IU/dose), normal (6184IU/dose) and high (12,554IU/dose) were used. Three SICTTs (using) were conducted on 2102 animals. Test results were compared based on reactor-status and changes in skin-thickness at the bovine tuberculin injection site. There was a significant difference in the number of reactors detected using the high and low potency tuberculins. In the SICTT, high and low potency tuberculin detected 40% more and 50% fewer reactors, respectively, than normal potency tuberculin. Furthermore, use of the low potency tuberculin in the SICTT failed to detect 20% of 35 animals with visible lesions, and in the SIT 11% of the visible lesion animals would have been classified as negative. Tuberculin potency is critical to the performance of both the SICTT and SIT. Tuberculin of different potencies will affect reactor disclosure rates, confounding between-year or between-country comparisons. Independent checks of tuberculin potency are an important aspect of quality control in national BTB control programmes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. 40 CFR 60.3035 - May I conduct performance testing less often?

    Science.gov (United States)

    2010-07-01

    ... deviation from an emission limitation for any pollutant, you must conduct annual performance tests for that... 40 Protection of Environment 6 2010-07-01 2010-07-01 false May I conduct performance testing less... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance...

  1. 40 CFR 60.2934 - May I conduct performance testing less often?

    Science.gov (United States)

    2010-07-01

    ... deviation from an emission limitation for any pollutant, you must conduct annual performance tests for that... 40 Protection of Environment 6 2010-07-01 2010-07-01 false May I conduct performance testing less... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Operator Training and...

  2. Ankle taping does not impair performance in jump or balance tests.

    Science.gov (United States)

    Abián-Vicén, Javier; Alegre, Luis M; Fernández-Rodríguez, J Manuel; Lara, Amador J; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces.

  3. An accurate definition of the status of inactive hepatitis B virus carrier by a combination of biomarkers (FibroTest-ActiTest and viral load.

    Directory of Open Access Journals (Sweden)

    Yen Ngo

    Full Text Available BACKGROUND: The combination of transaminases (ALT, biopsy, HBeAg and viral load have classically defined the inactive status of carriers of chronic hepatitis B. The use of FibroTest (FT and ActiTest (AT, biomarkers of fibrosis and necroinflammatory activity, has been previously validated as alternatives to biopsy. We compared the 4-year prognostic value of combining FT-AT and viral load for a better definition of the inactive carrier status. METHODS AND FINDINGS: 1,300 consecutive CHB patients who had been prospectively followed since 2001 were pre-included. The main endpoint was the absence of liver-related complications, transplantation or death. We used the manufacturers' definitions of normal FT (< = 0.27, normal AT (< = 0.29 and 3 standard classes for viral load. The adjustment factors were age, sex, HBeAg, ethnic origin, alcohol consumption, HIV-Delta-HCV co-infections and treatment. RESULTS: 1,074 patients with baseline FT-AT and viral load were included: 41 years old, 47% African, 27% Asian, 26% Caucasian. At 4 years follow-up, 50 complications occurred (survival without complications 93.4%, 36 deaths occurred (survival 95.0%, including 27 related to HBV (survival 96.1%. The prognostic value of FT was higher than those of viral load or ALT when compared using area under the ROC curves [0.89 (95%CI 0.84-0.93 vs 0.64 (0.55-0.71 vs 0.53 (0.46-0.60 all P<0.001], survival curves and multivariate Cox model [regression coefficient 5.2 (3.5-6.9; P<0.001 vs 0.53 (0.15-0.92; P = 0.007 vs -0.001 (-0.003-0.000;P = 0.052] respectively. A new definition of inactive carriers was proposed with an algorithm combining "zero" scores for FT-AT (F0 and A0 and viral load classes. This new algorithm provides a 100% negative predictive value for the prediction of liver related complications or death. Among the 275 patients with the classic definition of inactive carrier, 62 (23% had fibrosis presumed with FT, and 3 died or had complications at 4 year

  4. NetBench. Automated Network Performance Testing

    CERN Document Server

    Cadeddu, Mattia

    2016-01-01

    In order to evaluate the operation of high performance routers, CERN has developed the NetBench software to run benchmarking tests by injecting various traffic patterns and observing the network devices behaviour in real-time. The tool features a modular design with a Python based console used to inject traffic and collect the results in a database, and a web user

  5. Large scale and performance tests of the ATLAS online software

    International Nuclear Information System (INIS)

    Alexandrov; Kotov, V.; Mineev, M.; Roumiantsev, V.; Wolters, H.; Amorim, A.; Pedro, L.; Ribeiro, A.; Badescu, E.; Caprini, M.; Burckhart-Chromek, D.; Dobson, M.; Jones, R.; Kazarov, A.; Kolos, S.; Liko, D.; Lucio, L.; Mapelli, L.; Nassiakou, M.; Schweiger, D.; Soloviev, I.; Hart, R.; Ryabov, Y.; Moneta, L.

    2001-01-01

    One of the sub-systems of the Trigger/DAQ system of the future ATLAS experiment is the Online Software system. It encompasses the functionality needed to configure, control and monitor the DAQ. Its architecture is based on a component structure described in the ATLAS Trigger/DAQ technical proposal. Regular integration tests ensure its smooth operation in test beam setups during its evolutionary development towards the final ATLAS online system. Feedback is received and returned into the development process. Studies of the system behavior have been performed on a set of up to 111 PCs on a configuration which is getting closer to the final size. Large scale and performance test of the integrated system were performed on this setup with emphasis on investigating the aspects of the inter-dependence of the components and the performance of the communication software. Of particular interest were the run control state transitions in various configurations of the run control hierarchy. For the purpose of the tests, the software from other Trigger/DAQ sub-systems has been emulated. The author presents a brief overview of the online system structure, its components and the large scale integration tests and their results

  6. The Empirical Testing of a Musical Performance Assessment Paradigm

    Science.gov (United States)

    Russell, Brian E.

    2010-01-01

    The purpose of this study was to test a hypothesized model of aurally perceived performer-controlled musical factors that influence assessments of performance quality. Previous research studies on musical performance constructs, musical achievement, musical expression, and scale construction were examined to identify the factors that influence…

  7. Experience from performance testing of low NOx burners for refinery heaters; Tests de performance avec des bruleurs de raffinerie a basse emission de NOx

    Energy Technology Data Exchange (ETDEWEB)

    Boden, J.C. [Refining Technology, BP Oil International, Sunbury (United Kingdom)

    2001-07-01

    Developments in low NOx burner technology have resulted in major reductions in NOx emissions from refinery process heaters. However, the techniques used in low NOx burners to reduce NOx emissions can potentially affect other key aspects of burner performance, particularly flame stability and completeness of combustion. BP has evaluated many of the currently available low and ultra-low NOx burners, both natural and forced draught, in its purpose-built test furnace. This extensive test programme has shown that to be a reliable predictor of actual performance a test rig must recreate accurately the real furnace conditions, particularly with respect to furnace and hearth temperatures. The testing has demonstrated the NOx emissions to be expected in practice from different generic types of burner, conventional, low NOx and ultra-low NOx, and has highlighted the sets of conditions most likely to lead to combustion performance problems. (authors)

  8. Spread of status value: Rewards and the creation of status characteristics.

    Science.gov (United States)

    Harkness, Sarah K

    2017-01-01

    Rewards have social significance and are highly esteemed objects, but what does their ownership signify to others? Prior work has demonstrated it may be possible for these rewards to spread their status to those who possess them, such that individuals gain or lose status and influence by virtue of the rewards they display. Yet, is this spread enough to produce entirely new status characteristics by virtue of their association with rewards? I propose a theoretical extension of the spread of status value theory and offer an experimental test considering whether the status value conveyed by rewards spreads to a new, nominal characteristic of those who come to possess these objects. The results indicate that states of a nominal characteristic do gain or lose status value and behavioral influence through their association with differentially valued rewards. Thus, rewards can create new status characteristics with resulting behavioral expectations. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Expert status and performance.

    Directory of Open Access Journals (Sweden)

    Mark A Burgman

    Full Text Available Expert judgements are essential when time and resources are stretched or we face novel dilemmas requiring fast solutions. Good advice can save lives and large sums of money. Typically, experts are defined by their qualifications, track record and experience. The social expectation hypothesis argues that more highly regarded and more experienced experts will give better advice. We asked experts to predict how they will perform, and how their peers will perform, on sets of questions. The results indicate that the way experts regard each other is consistent, but unfortunately, ranks are a poor guide to actual performance. Expert advice will be more accurate if technical decisions routinely use broadly-defined expert groups, structured question protocols and feedback.

  10. Important Details in Performing and Interpreting the Scratch Collapse Test.

    Science.gov (United States)

    Kahn, Lorna C; Yee, Andrew; Mackinnon, Susan E

    2018-02-01

    The utility of the scratch collapse test has been demonstrated in examination of patients with carpal and cubital tunnel syndromes and long thoracic and peroneal nerve compressions. In the authors' clinic, this lesser known test plays a key role in peripheral nerve examination where localization of the nerve irritation or injury is not fully understood. Test utility and accuracy in patients with more challenging presentations likely correlate with tester understanding and experience. This article offers a clear outline of all stages of the test to improve interrater reliability. The nuances of test performance are described, including a description of situations where the scratch collapse test is deemed inappropriate. Four clinical scenarios where the scratch collapse test may be useful are included. Corresponding video content is provided to improve performance and interpretation of the scratch collapse test. Diagnostic, V.

  11. Heating facility for blanket and performance test

    Energy Technology Data Exchange (ETDEWEB)

    Furuya, Kazuyuki; Kuroda, Toshimasa; Enoeda, Mikio; Sato, Satoshi; Hatano, Toshihisa; Takatsu, Hideyuki; Ohara, Yoshihiro [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Hara, Shigemitsu

    1999-03-01

    A design and a fabrication of heating test facility for a mock-up of the blanket module to be installed in International Thermonuclear Experimental Reactor (ITER) have been conducted to evaluate/demonstrate its heat removal performance and structural soundness under cyclic heat loads. To simulate surface heat flux to the blanket module, infrared heating method is adopted so as to heat large surface area uniformly. The infrared heater is used in vacuum environment (10{sup -4} Torr{approx}), and the lamps are cooled by air flowing through an annulus between the lamp and a cover tube made of quartz glass. Elastomer O rings (available to be used up to {approx}300degC) and used for vacuum seal at outer surface of the cover tube. To prevent excessive heating of the O ring, the end part of the cover tube is specially designed including the tube shape, flow path of air and gold coating on the surface of the cover tube to protect the O ring against thermal radiation from glowing tungsten filament. To examine the performance of the facility, steady state and cyclic operation of the infrared heater were conducted using a small-scaled shielding blanket mock-up as a test specimen. The important results are as follows: (1) Heat flux at the surface of the small-scaled mock-up measured by a calorimeter was {approx}0.2 MW/m{sup 2}. (2) A comparison of thermal analysis results and measured temperature responses showed that the small-scaled mock-up had good heat removal performance. (3) Steady state operation and cyclic operation with step response between the rated and zero powers of the infrared heater were successfully performed, and it was confirmed that this heating facility was well-prepared and available for the thermal cyclic test of a blanket module. (author)

  12. What matters when judging intentionality-moral content or normative status? Testing the rational scientist model of the side-effect.

    Science.gov (United States)

    Papadopoulos, C; Hayes, B K

    2018-06-01

    Previous work has demonstrated a "side-effect effect," such that intentionality is more likely to be attributed to agents who bring about negatively valenced as opposed to positively valenced side effects. The rational-scientist model explains this by suggesting that norm-violating side effects are more informative for inferring intentionality than norm-conforming side effects. In the present study we reexamined this account, addressing limitations of previous empirical tests (e.g., Uttich & Lombrozo, Cognition 116: 87-100, 2010). Side-effect valence and norm status were manipulated factorially, enabling an examination of the impact of norm status on intentionality judgments in both positively and negatively valenced side effects. Additionally, the impact of side-effect norm status on the perceived valences of side effects and agents was examined. Effects of norm status were found for both positive and negative side effects. Violation of an ostensibly neutral norm led to negative perceptions of the side effect. However, a norm status effect on intentionality judgments persisted when these effects were controlled. These results support the view that the side-effect effect is the result of the rational use of social-cognitive evidence.

  13. The Functional Test for Agility Performance is a Reliable Quick Decision-Making Test for Skilled Water Polo Players

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2015-06-01

    Full Text Available The reliability of the Functional Test for Agility Performance has only been evaluated in water polo players in a small group of novice athletes. Thus, the aim of this study was to evaluate the reliability of the Functional Test for Agility Performance in skilled water polo players. Forty-two athletes (17.81 ± 3.24 years old with a minimum of 5 years of competitive experience (7.05 ± 2.84 years and playing at the national or international level were evaluated. The Functional Test for Agility Performance is characterized as a specific open decision-making test where a tested player moves as quickly as possible in accordance to a pass made by another player. The time spent in the test was measured by two experienced coaches. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. Athletes completed the Functional Test for Agility Performance in 4.15 0.47 s. The ICC value was 0.87 (95% IC = 0.80-0.92. The SEM varied between 0.24 and 0.38 s. The LOA was 1.20 s and the CV average considering each individual trial was 6%. The Functional Test for Agility Performance was shown to be a reliable quick decision-making test for skilled water polo players.

  14. The Functional Classification and Field Test Performance in Wheelchair Basketball Players.

    Science.gov (United States)

    Gil, Susana María; Yanci, Javier; Otero, Montserrat; Olasagasti, Jurgi; Badiola, Aduna; Bidaurrazaga-Letona, Iraia; Iturricastillo, Aitor; Granados, Cristina

    2015-06-27

    Wheelchair basketball players are classified in four classes based on the International Wheelchair Basketball Federation (IWBF) system of competition. Thus, the aim of the study was to ascertain if the IWBF classification, the type of injury and the wheelchair experience were related to different performance field-based tests. Thirteen basketball players undertook anthropometric measurements and performance tests (hand dynamometry, 5 m and 20 m sprints, 5 m and 20 m sprints with a ball, a T-test, a Pick-up test, a modified 10 m Yo-Yo intermittent recovery test, a maximal pass and a medicine ball throw). The IWBF class was correlated (pstaff and coaches of the teams when assessing performance of wheelchair basketball players.

  15. Improving Test-Taking Performance of Secondary At-Risk Youth and Students with Disabilities

    Science.gov (United States)

    Banks, Tachelle; Eaton, India

    2014-01-01

    Preparing at-risk youth and students with mild disabilities for state and district tests is important for improving their test performance, and basic instruction in test preparation can significantly improve student test performance. The article defines noncognitive variables that adversely affect test-taker performance. The article also describes…

  16. Closure plan for the Test Area North-726 chromate water storage and Test Area North-726A chromate treatment units

    International Nuclear Information System (INIS)

    Smith, P.J.; Van Brunt, K.M.

    1992-11-01

    This document describes the proposed plan for closure of the Test Area North-726 chromate water storage and Test Area North-726A chromate treatment units at the Idaho National Engineering Laboratory in accordance with the Resource Conservation and Recovery Act interim status closure requirements. The location, size, capacity, and history of the units are described, and their current status is discussed. The units will be closed by treating remaining waste in storage, followed by thorough decontamination of the systems. Sufficient sampling and analysis, and documentation of all activities will be performed to demonstrate clean closure

  17. Preliminary results of testing bioassay analytical performance standards

    International Nuclear Information System (INIS)

    Fisher, D.R.; Robinson, A.V.; Hadley, R.T.

    1983-08-01

    The analytical performance of both in vivo and in vitro bioassay laboratories is being studied to determine the capability of these laboratories to meet the minimum criteria for accuracy and precision specified in the draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. This paper presents preliminary results of the first round of testing

  18. Comparison of test performance profile for blood tests of liver fibrosis in chronic hepatitis C.

    Science.gov (United States)

    Halfon, Philippe; Bacq, Yannick; De Muret, Anne; Penaranda, Guillaume; Bourliere, Marc; Ouzan, Denis; Tran, Albert; Botta, Danielle; Renou, Christophe; Bréchot, Marie-Claude; Degott, Claude; Paradis, Valérie

    2007-03-01

    We evaluated the test performance profile (TPP) of blood tests of liver fibrosis. Three hundred and fifty-six patients with C chronic hepatitis were included in two centers. Metavir staging of liver specimens by two independent pathologists and the following tests were evaluated: Fibrotest (FT), APRI, FibroMeter (FM), and Hepascore (HS). Metavir stages were: F0: 4%, F1: 55%, F2: 26%, F3: 11%, and F4: 4%. The AUROCs were not significantly different, respectively, FT, FM, APRI, HS: >or=F2: 0.79, 0.78, 0.76, >or=0.76; F3: 0.81, 0.85, 0.81, 0.81; and F4: 0.86, 0.94, 0.92, 0.89. The TPP relies on the paired comparison of blood-test misclassification based on liver specimen, e.g. FT vs FM, respectively: F0+1: 18 vs 28% (p=0.0003), >or=F2: 43 vs 31% (p=0.004). There was no center effect. In those populations, the four blood tests had a similar performance for significant fibrosis (F>or=2), lying in the lower range of published results which is attributable to a low >or=F2 prevalence, and for >or=F3 and F4. However, FM and FT had performance profiles significantly different as a function of fibrosis stages or diagnostic target (fibrosis cut-off). This has to be considered during the interpretation process. Moreover, the performance should be reported with different diagnostic targets.

  19. A better state-of-mind: deep breathing reduces state anxiety and enhances test performance through regulating test cognitions in children.

    Science.gov (United States)

    Khng, Kiat Hui

    2017-11-01

    A pre-test/post-test, intervention-versus-control experimental design was used to examine the effects, mechanisms and moderators of deep breathing on state anxiety and test performance in 122 Primary 5 students. Taking deep breaths before a timed math test significantly reduced self-reported feelings of anxiety and improved test performance. There was a statistical trend towards greater effectiveness in reducing state anxiety for boys compared to girls, and in enhancing test performance for students with higher autonomic reactivity in test-like situations. The latter moderation was significant when comparing high-versus-low autonomic reactivity groups. Mediation analyses suggest that deep breathing reduces state anxiety in test-like situations, creating a better state-of-mind by enhancing the regulation of adaptive-maladaptive thoughts during the test, allowing for better performance. The quick and simple technique can be easily learnt and effectively applied by most children to immediately alleviate some of the adverse effects of test anxiety on psychological well-being and academic performance.

  20. Wafer-level radiometric performance testing of uncooled microbolometer arrays

    Science.gov (United States)

    Dufour, Denis G.; Topart, Patrice; Tremblay, Bruno; Julien, Christian; Martin, Louis; Vachon, Carl

    2014-03-01

    A turn-key semi-automated test system was constructed to perform on-wafer testing of microbolometer arrays. The system allows for testing of several performance characteristics of ROIC-fabricated microbolometer arrays including NETD, SiTF, ROIC functionality, noise and matrix operability, both before and after microbolometer fabrication. The system accepts wafers up to 8 inches in diameter and performs automated wafer die mapping using a microscope camera. Once wafer mapping is completed, a custom-designed quick insertion 8-12 μm AR-coated Germanium viewport is placed and the chamber is pumped down to below 10-5 Torr, allowing for the evaluation of package-level focal plane array (FPA) performance. The probe card is electrically connected to an INO IRXCAM camera core, a versatile system that can be adapted to many types of ROICs using custom-built interface printed circuit boards (PCBs). We currently have the capability for testing 384x288, 35 μm pixel size and 160x120, 52 μm pixel size FPAs. For accurate NETD measurements, the system is designed to provide an F/1 view of two rail-mounted blackbodies seen through the Germanium window by the die under test. A master control computer automates the alignment of the probe card to the dies, the positioning of the blackbodies, FPA image frame acquisition using IRXCAM, as well as data analysis and storage. Radiometric measurement precision has been validated by packaging dies measured by the automated probing system and re-measuring the SiTF and Noise using INO's pre-existing benchtop system.