WorldWideScience

Sample records for performance testing collected

  1. A new test procedure to evaluate the performance of substations for collective heating systems

    Science.gov (United States)

    Baetens, Robin; Verhaert, Ivan

    2017-11-01

    The overall heat demand of a single dwelling, existing out of space heating and domestic hot water production, decreases due to higher insulation rates. Because of this, investing in efficient and renewable heat generation becomes less interesting. Therefore, to incorporate renewables or residual heat on a larger scale, district heating or collective heating systems grow in importance. Within this set-up, the substation is responsible for the interaction between local demand for comfort and overall energy performance of the collective heating system. Many different configurations of substations exist, which influence both local comfort and central system performance. Next to that, also hybrids exist with additional local energy input. To evaluate performance of such substations, a new experimental-based test procedure is developed in order to evaluate these different aspects, characterized by the two roles a substation has, namely as heat generator and as heat consumer. The advantage of this approach is that an objective comparison between individual and central systems regarding performance on delivering local comfort can be executed experimentally. The lab set-up consists out of three different subsystems, namely the central system, the domestic hot water consumption and the local space heating. The central system can work with different temperature regimes and control strategies, as these aspects have proven to have the largest influence on actual performance. The domestic hot water system is able to generate similar tap profiles according to eco-design regulation for domestic hot water generation. The space heating system is able to demand a modular heat load.

  2. A new test procedure to evaluate the performance of substations for collective heating systems

    Directory of Open Access Journals (Sweden)

    Baetens Robin

    2017-01-01

    Full Text Available The overall heat demand of a single dwelling, existing out of space heating and domestic hot water production, decreases due to higher insulation rates. Because of this, investing in efficient and renewable heat generation becomes less interesting. Therefore, to incorporate renewables or residual heat on a larger scale, district heating or collective heating systems grow in importance. Within this set-up, the substation is responsible for the interaction between local demand for comfort and overall energy performance of the collective heating system. Many different configurations of substations exist, which influence both local comfort and central system performance. Next to that, also hybrids exist with additional local energy input. To evaluate performance of such substations, a new experimental-based test procedure is developed in order to evaluate these different aspects, characterized by the two roles a substation has, namely as heat generator and as heat consumer. The advantage of this approach is that an objective comparison between individual and central systems regarding performance on delivering local comfort can be executed experimentally. The lab set-up consists out of three different subsystems, namely the central system, the domestic hot water consumption and the local space heating. The central system can work with different temperature regimes and control strategies, as these aspects have proven to have the largest influence on actual performance. The domestic hot water system is able to generate similar tap profiles according to eco-design regulation for domestic hot water generation. The space heating system is able to demand a modular heat load.

  3. Sparse matrix test collections

    Energy Technology Data Exchange (ETDEWEB)

    Duff, I.

    1996-12-31

    This workshop will discuss plans for coordinating and developing sets of test matrices for the comparison and testing of sparse linear algebra software. We will talk of plans for the next release (Release 2) of the Harwell-Boeing Collection and recent work on improving the accessibility of this Collection and others through the World Wide Web. There will only be three talks of about 15 to 20 minutes followed by a discussion from the floor.

  4. Performing T-tests to Compare Autocorrelated Time Series Data Collected from Direct-Reading Instruments.

    Science.gov (United States)

    O'Shaughnessy, Patrick; Cavanaugh, Joseph E

    2015-01-01

    Industrial hygienists now commonly use direct-reading instruments to evaluate hazards in the workplace. The stored values over time from these instruments constitute a time series of measurements that are often autocorrelated. Given the need to statistically compare two occupational scenarios using values from a direct-reading instrument, a t-test must consider measurement autocorrelation or the resulting test will have a largely inflated type-1 error probability (false rejection of the null hypothesis). A method is described for both the one-sample and two-sample cases which properly adjusts for autocorrelation. This method involves the computation of an "equivalent sample size" that effectively decreases the actual sample size when determining the standard error of the mean for the time series. An example is provided for the one-sample case, and an example is given where a two-sample t-test is conducted for two autocorrelated time series comprised of lognormally distributed measurements.

  5. Test performance and acceptability of self- versus provider-collected swabs for high-risk HPV DNA testing in female-to-male trans masculine patients.

    Science.gov (United States)

    Reisner, Sari L; Deutsch, Madeline B; Peitzmeier, Sarah M; White Hughto, Jaclyn M; Cavanaugh, Timothy P; Pardee, Dana J; McLean, Sarah A; Panther, Lori A; Gelman, Marcy; Mimiaga, Matthew J; Potter, Jennifer E

    2018-01-01

    High-risk human papillomavirus (hrHPV) causes virtually all cervical cancers. Trans masculine (TM) people (those assigned female at birth who identify with a gender other than female) have low uptake of conventional cervical cancer screening. Self-collected hrHPV DNA testing has high levels of acceptability among cisgender (non-transgender) females and may support increased cervical cancer screening uptake in TM individuals. To assess the test performance and acceptability of self-collected vaginal specimens in comparison to provider-collected cervical swabs for hrHPV DNA detection in TM individuals ages 21-64 years. Between March 2015-September 2016, 150 TM participants with a cervix (mean age = 27.5 years; SD = 5.7) completed a one-time study visit comprised of a self-report survey, self-collected vaginal HPV DNA swab, clinician-administered cervical HPV swab, and brief interview on acceptability of clinical procedures. Participants were randomized to complete either self- or provider-collection first to minimize ordering effects. Self- and provider-collected samples were tested for 13 hrHPV DNA types using a DNA Hybridization Assay. The primary outcome variable was the concordance (kappa statistic) and performance (sensitivity, specificity) of self-collected vaginal HPV DNA specimens versus provider-collected cervical HPV swabs as the gold standard. Of the 131 participants completing both the self- and provider-collected HPV tests, 21 cases of hrHPV were detected by the provider cervical swab (gold standard; 16.0% hrHPV prevalence); 15 of these cases were accurately detected by the self-collected vaginal swab (71.4% concordance) (Kappa = 0.75, 95% Confidence Interval [CI]: 0.59, 0.92; p<0.001). Compared to the provider-collected cervical hrHPV DNA sample (gold standard), the self-collected vaginal hrHPV DNA test demonstrated a sensitivity of 71.4% (95% CI: 0.52, 0.91; p = 0.0495) and specificity of 98.2% (95% CI: 0.96, 1.00; p<0.0001). Over 90% of participants

  6. Textiles Performance Testing Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Textiles Performance Testing Facilities has the capabilities to perform all physical wet and dry performance testing, and visual and instrumental color analysis...

  7. Statistical analysis in MSW collection performance assessment.

    Science.gov (United States)

    Teixeira, Carlos Afonso; Avelino, Catarina; Ferreira, Fátima; Bentes, Isabel

    2014-09-01

    The increase of Municipal Solid Waste (MSW) generated over the last years forces waste managers pursuing more effective collection schemes, technically viable, environmentally effective and economically sustainable. The assessment of MSW services using performance indicators plays a crucial role for improving service quality. In this work, we focus on the relevance of regular system monitoring as a service assessment tool. In particular, we select and test a core-set of MSW collection performance indicators (effective collection distance, effective collection time and effective fuel consumption) that highlights collection system strengths and weaknesses and supports pro-active management decision-making and strategic planning. A statistical analysis was conducted with data collected in mixed collection system of Oporto Municipality, Portugal, during one year, a week per month. This analysis provides collection circuits' operational assessment and supports effective short-term municipality collection strategies at the level of, e.g., collection frequency and timetables, and type of containers. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Performing Inferential Statistics Prior to Data Collection

    Science.gov (United States)

    Trafimow, David; MacDonald, Justin A.

    2017-01-01

    Typically, in education and psychology research, the investigator collects data and subsequently performs descriptive and inferential statistics. For example, a researcher might compute group means and use the null hypothesis significance testing procedure to draw conclusions about the populations from which the groups were drawn. We propose an…

  9. Test planning and performance

    International Nuclear Information System (INIS)

    Zola, Maurizio

    2001-01-01

    Testing plan should include Safety guide Q4 - Inspection and testing - A testing plan should be prepared including following information: General information (facility name, item or system reference, procurement document reference, document reference number and status, associated procedures and drawings); A sequential listing of all testing activities; Procedure, work instruction, specification or standard to be followed in respect of each operation and test; Acceptance criteria; Identification of who is performing tests; Identification of hold points; Type of records to be prepared for each test; Persons and organizations having authority for final acceptance. Proposed activities sequence is: visual, electrical and mechanical checks; environmental tests (thermal aging, vibrations aging, radioactive aging); performance evaluation in extreme conditions; dynamic tests with functional checks; final electrical and mechanical checks The planning of the tests should always be performed taking into account an interpretative model: a very tight cooperation is advisable between experimental people and numerical people dealing with the analysis of more or less complex models for the seismic assessment of structures and components. Preparatory phase should include the choice of the following items should be agreed upon with the final user of the tests: Excitation points, Excitation types, Excitation amplitude with respect to frequency, Measuring points. Data acquisition, recording and storage, should take into account the characteristics of the successive data processing: to much data can be cumbersome to be processed, but to few data can make unusable the experimental results. The parameters for time history acquisition should be chosen taking into account data processing: for Shock Response Spectrum calculation some special requirements should be met: frequency bounded signal, high frequency sampling, shock noise. For stationary random-like excitation, the sample length

  10. System Performance and Testing

    NARCIS (Netherlands)

    Frei, U.; Oversloot, H.

    2004-01-01

    This chapter compares and contrasts the system performance of two widely used solar thermal systems using testing and simulation programs. Solar thermal systems are used in many countries for heating domestically used water. In addition to the simple thermosiphon systems, better designed pumped

  11. The performance testing

    International Nuclear Information System (INIS)

    Mayr, A.

    1975-01-01

    Concerning the time-schedule of reactor performance tests they normally begin when suppliers or constructors have finished construction and made all necessary construction and coordinated tests. If the last-mentioned tests are conducted profoundly, they contribute substantially to a quick and simple carrying-out of the last performance tests and to the general quality of components and systems. At this stage all components of a system should be properly fixed, machinery, instruments and electrical components adjusted and calibrated, all set-points tested, electrical and other supply units in operation or ready to operate and all functions pretested. Just at this stage of the work most of the existing defects and failures of systems can be found. Remembering the fact that the difficulty of operation of complex systems results from detail problems, it is extremely useful to remove all things of this kind as soon as possible, at the latest at this time where it is done easily and normally quickly without influencing start-up-procedures of other systems or even of the total plant. (orig./TK) [de

  12. Understanding protocol performance: impact of test performance.

    Science.gov (United States)

    Turner, Robert G

    2013-01-01

    This is the second of two articles that examine the factors that determine protocol performance. The objective of these articles is to provide a general understanding of protocol performance that can be used to estimate performance, establish limits on performance, decide if a protocol is justified, and ultimately select a protocol. The first article was concerned with protocol criterion and test correlation. It demonstrated the advantages and disadvantages of different criterion when all tests had the same performance. It also examined the impact of increasing test correlation on protocol performance and the characteristics of the different criteria. To examine the impact on protocol performance when individual tests in a protocol have different performance. This is evaluated for different criteria and test correlations. The results of the two articles are combined and summarized. A mathematical model is used to calculate protocol performance for different protocol criteria and test correlations when there are small to large variations in the performance of individual tests in the protocol. The performance of the individual tests that make up a protocol has a significant impact on the performance of the protocol. As expected, the better the performance of the individual tests, the better the performance of the protocol. Many of the characteristics of the different criteria are relatively independent of the variation in the performance of the individual tests. However, increasing test variation degrades some criteria advantages and causes a new disadvantage to appear. This negative impact increases as test variation increases and as more tests are added to the protocol. Best protocol performance is obtained when individual tests are uncorrelated and have the same performance. In general, the greater the variation in the performance of tests in the protocol, the more detrimental this variation is to protocol performance. Since this negative impact is increased as

  13. On the reusability of open test collections

    NARCIS (Netherlands)

    Hashemi, S.H.; Clarke, C.L.A.; Dean-Hall, A.; Kamps, J.; Kiseleva, Y.

    2015-01-01

    Creating test collections for modern search tasks is increasingly more challenging due to the growing scale and dynamic nature of content, and need for richer contextualization of the statements of request. To address these issues, the TREC Contextual Suggestion Track explored an open test

  14. Performance test for a solar water heater

    Science.gov (United States)

    1979-01-01

    Two reports describe procedures and results of performance tests on domestic solar powered hot water system. Performance tests determine amount of energy collected by system, amount of energy delivered to solar source, power required to operate system and maintain proper tank temperature, overall system efficiency, and temperature distribution in tank.

  15. Uniform peanut performance test 2017

    Science.gov (United States)

    The Uniform Peanut Performance Tests (UPPT) are designed to evaluate the commercial potential of advanced breeding peanut lines not formally released. The tests are performed in ten locations across the peanut production belt. In this study, 2 controls and 14 entries were evaluated at 8 locations....

  16. Inspection system performance test procedure

    International Nuclear Information System (INIS)

    Jensen, C.E.

    1995-01-01

    This procedure establishes requirements to administer a performance demonstration test. The test is to demonstrate that the double-shell tank inspection system (DSTIS) supplied by the contractor performs in accordance with the WHC-S-4108, Double-Shell Tank Ultrasonic Inspection Performance Specification, Rev. 2-A, January, 1995. The inspection system is intended to provide ultrasonic (UT) and visual data to determine integrity of the Westinghouse Hanford Company (WHC) site underground waste tanks. The robotic inspection system consists of the following major sub-systems (modules) and components: Mobile control center; Deployment module; Cable management assembly; Robot mechanism; Ultrasonic testing system; Visual testing system; Pneumatic system; Electrical system; and Control system

  17. Compressible Fluid Suspension Performance Testing

    National Research Council Canada - National Science Library

    Hoogterp, Francis

    2003-01-01

    ... compressible fluid suspension system that was designed and installed on the vehicle by DTI. The purpose of the tests was to evaluate the possible performance benefits of the compressible fluid suspension system...

  18. Where Lab Tests Are Performed

    Science.gov (United States)

    ... example, there may be sections that focus on microbiology, hematology, chemistry, and blood banking . Other units may perform highly specialized tests using electron microscopy and immunohistochemistry, and still others ...

  19. Performance testing With JMeter 29

    CERN Document Server

    Erinle, Bayo

    2013-01-01

    Performance Testing With JMeter 2.9 is a standard tutorial that will help you polish your fundamentals, guide you through various advanced topics, and along the process help you learn new tools and skills.This book is for developers, quality assurance engineers, testers, and test managers new to Apache JMeter, or those who are looking to get a good grounding in how to effectively use and become proficient with it. No prior testing experience is required.

  20. Career Development, Collective Efficacy, and Individual Task Performance

    Science.gov (United States)

    Kellett, Janet B.; Humphrey, Ronald H.; Sleeth, Randall G.

    2009-01-01

    Purpose: The purpose of this paper is to test the hypothesis that perceived collective efficacy would mediate the effects of self-efficacy on individual task performance. Design/methodology/approach: An assessment center design with 147 participants in 49 three-person groups was used. Findings: It is found that for individuals working on an…

  1. NetBench. Automated Network Performance Testing

    CERN Document Server

    Cadeddu, Mattia

    2016-01-01

    In order to evaluate the operation of high performance routers, CERN has developed the NetBench software to run benchmarking tests by injecting various traffic patterns and observing the network devices behaviour in real-time. The tool features a modular design with a Python based console used to inject traffic and collect the results in a database, and a web user

  2. Performance Testing of Cutting Fluids

    DEFF Research Database (Denmark)

    Belluco, Walter

    The importance of cutting fluid performance testing has increased with documentation requirements of new cutting fluid formulations based on more sustainable products, as well as cutting with minimum quantity of lubrication and dry cutting. Two sub-problems have to be solved: i) which machining...... tests feature repeatability, reproducibility and sensitivity to cutting fluids, and ii) to what extent results of one test ensure relevance to a wider set of machining situations. The present work is aimed at assessing the range of validity of the different testing methods, investigating correlation...... within the whole range of operations, materials, cutting fluids, operating conditions, etc. Cutting fluid performance was evaluated in turning, drilling, reaming and tapping, and with respect to tool life, cutting forces, chip formation and product quality (dimensional accuracy and surface integrity...

  3. LFK, FORTRAN Application Performance Test

    International Nuclear Information System (INIS)

    McMahon, F.H.

    1991-01-01

    1 - Description of program or function: LFK, the Livermore FORTRAN Kernels, is a computer performance test that measures a realistic floating-point performance range for FORTRAN applications. Informally known as the Livermore Loops test, the LFK test may be used as a computer performance test, as a test of compiler accuracy (via checksums) and efficiency, or as a hardware endurance test. The LFK test, which focuses on FORTRAN as used in computational physics, measures the joint performance of the computer CPU, the compiler, and the computational structures in units of Mega-flops/sec or Mflops. A C language version of subroutine KERNEL is also included which executes 24 samples of C numerical computation. The 24 kernels are a hydrodynamics code fragment, a fragment from an incomplete Cholesky conjugate gradient code, the standard inner product function of linear algebra, a fragment from a banded linear equations routine, a segment of a tridiagonal elimination routine, an example of a general linear recurrence equation, an equation of state fragment, part of an alternating direction implicit integration code, an integrate predictor code, a difference predictor code, a first sum, a first difference, a fragment from a two-dimensional particle-in-cell code, a part of a one-dimensional particle-in-cell code, an example of how casually FORTRAN can be written, a Monte Carlo search loop, an example of an implicit conditional computation, a fragment of a two-dimensional explicit hydrodynamics code, a general linear recurrence equation, part of a discrete ordinates transport program, a simple matrix calculation, a segment of a Planck distribution procedure, a two-dimensional implicit hydrodynamics fragment, and determination of the location of the first minimum in an array. 2 - Method of solution: CPU performance rates depend strongly on the maturity of FORTRAN compiler machine code optimization. The LFK test-bed executes the set of 24 kernels three times, resetting the DO

  4. Radioactive material packaging performance testing

    International Nuclear Information System (INIS)

    Romano, T.; Cruse, J.M.

    1991-02-01

    To provide uniform packaging of hazardous materials on an international level, the United Nations has developed packaging recommendations that have been implemented worldwide. The United Nations packaging recommendations are performance oriented, allowing for a wide variety of package materials and systems. As a result of this international standard, efforts in the United States are being directed toward use of performance-oriented packaging and elimination of specification (designed) packaging. This presentation will focus on trends, design evaluation, and performance testing of radioactive material packaging. The impacts of US Department of Transportation Dockets HM-181 and HM-169A on specification and low-specific activity radioactive material packaging requirements are briefly discussed. The US Department of Energy's program for evaluating radioactive material packings per US Department of Transportation Specification 7A Type A requirements, is used as the basis for discussing low-activity packaging performance test requirements. High-activity package testing requirements are presented with examples of testing performed at the Hanford Site that is operated by Westinghouse Hanford Company for the US Department of Energy. 5 refs., 2 tabs

  5. GEM: Performance and aging tests

    International Nuclear Information System (INIS)

    Cho, H.S.; Kadyk, J.; Han, S.H.; Hong, W.S.; Perez-Mendez, V.; Wenzel, W.; Pitts, K.; Martin, M.D.; Hutchins, J.B.

    1999-01-01

    Performance and aging tests have been done to characterize Gas Electron Multipliers (GEMs), including further design improvements such as a thicker GEM and a closed GEM. Since the effective GEM gain is typically smaller than the absolute GEM gain, due to trapping of avalanche electrons at the bottom GEM electrode, the authors performed field simulations and measurements for better understanding, and discuss methods to eliminate this effect. Other performance parameters of the GEMs are also presented, including absolute GEM gain, short-term and long-term gain stabilities

  6. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Whinnery, LeRoy L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Phillips, Jason J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms (ATF), Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-25

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

  7. Measuring collections effort improves cash performance.

    Science.gov (United States)

    Shutts, Joe

    2009-09-01

    Having a satisfied work force can lead to an improved collections effort. Hiring the right people and training them ensures employee engagement. Measuring collections effort and offering incentives is key to revenue cycle success.

  8. Quality standards for sample collection in coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Lima-Oliveira, Gabriel; Guidi, Gian Cesare; Favaloro, Emmanuel J

    2012-09-01

    Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. Test Driven Development: Performing Art

    Science.gov (United States)

    Bache, Emily

    The art of Test Driven Development (TDD) is a skill that needs to be learnt, and which needs time and practice to master. In this workshop a select number of conference participants with considerable skill and experience are invited to perform code katas [1]. The aim is for them to demonstrate excellence and the use of Test Driven Development, and result in some high quality code. This would be for the benefit of the many programmers attending the conference, who could come along and witness high quality code being written using TDD, and get a chance to ask questions and provide feedback.

  10. Radioactive material packaging performance testing

    International Nuclear Information System (INIS)

    Romano, T.

    1992-06-01

    In an effort to provide uniform packaging of hazardous material on an international level, recommendations for the transport of dangerous goods have been developed by the United Nations. These recommendations are performance oriented and contrast with a large number of packaging specifications in the US Department of Transportation's hazard materials regulations. This dual system presents problems when international shipments enter the US Department of Transportation's system. Faced with the question of continuing a dual system or aligning with the international system, the Research and Special Programs Administration of the US Department of Transportation responded with Docket HM-181. This began the transition toward the international transportation system. Following close behind is Docket HM-169A, which addressed low specific activity radioactive material packaging. This paper will discuss the differences between performance-oriented and specification packaging, the transition toward performance-oriented packaging by the US Department of Transportation, and performance-oriented testing of radioactive material packaging by Westinghouse Hanford Company. Dockets HM-181 and HM-169A will be discussed along with Type A (low activity) and Type B (high activity) radioactive material packaging evaluations

  11. Revealed preference tests for collective household behavior

    NARCIS (Netherlands)

    Cherchye, L.J.H.; de Rock, B.; Vermeulen, F.M.P.; Verriest, E.; Molina, J.A.

    2011-01-01

    This chapter contains a state of the art of revealed preference tests for consistency of observed household behavior with Pareto efficiency. These tests are entirely nonparametric, since they do not require any assumptions regarding the parametric form of individual preferences or the intrahousehold

  12. Forest Seed Collection, Processing,and Testing

    DEFF Research Database (Denmark)

    Schmidt, Lars Holger

    2016-01-01

    This chapter pertains to the techniques of capturing the best genetic quality seeds a seed source can produce at the optimal time of high physiological maturity and maintaining these qualities throughout the handling processes, all at a minimum cost. Different collection and processing techniques...... apply to different species, seed types, situations, and purposes. Yet the collection and processing toolbox contains a number of “standard” methods for most of these groups. Records and documentation help in evaluating “best practice” for future method improvement, and it helps in linking offspring...... to seed source. Conditions are set for short- and long-term seed storage by their inert storability physiology. The potential storage life of seed may for some robust “orthodox” species be several decades, while no available storage conditions can maintain viability for sensitive “recalcitrant” seed. Seed...

  13. Test Performance Related Dysfunctional Beliefs

    Directory of Open Access Journals (Sweden)

    Recep TÜTÜNCÜ

    2012-11-01

    Full Text Available Objective: Examinations by using tests are very frequently used in educational settings and successful studying before the examinations is a complex matter to deal with. In order to understand the determinants of success in exams better, we need to take into account not only emotional and motivational, but also cognitive aspects of the participants such as dysfunctional beliefs. Our aim is to present the relationship between candidates’ characteristics and distorted beliefs/schemata just before an examination. Method: The subjects of the study were 30 female and 30 male physicians who were about to take the medical specialization exam (MSE in Turkey. Dysfunctional Attitude Scale (DAS and Young Schema Questionnaire Short Form (YSQ-SF were applied to the subjects. The statistical analysis was done using the F test, Mann-Whitney, Kruskal-Wallis, chi-square test and spearman’s correlation test. Results: It was shown that some of the DAS and YSQ-SF scores were significantly higher in female gender, in the group who could not pass the exam, who had repetitive examinations, who had their first try taking an examination and who were unemployed at the time of the examination. Conclusion: Our findings indicate that candidates seeking help before MSE examination could be referred for cognitive therapy or counseling even they do not have any psychiatric diagnosis due to clinically significant cognitive distortion. Measurement and treatment of cognitive distortions that have negative impact on MSE performance may improve the cost-effectiveness and mental well being of the young doctors.

  14. Pavement performance evaluation, phase II : data collection.

    Science.gov (United States)

    2008-12-01

    Phase I and II of this study tested approximately 1500 rehabilitated pavements (asphalt and PCC) : throughout the State. These pavements ranged from 5 to 15 years old and were intended to develop a : snapshot of how various rehabilitations were perfo...

  15. Collective Protection (COLPRO) Novel Closures Testing

    Science.gov (United States)

    2013-03-28

    properly secured to avoid incidental movement . Mixing fans must not be placed inside the TFA. e. The dissemination system must be able to maintain the...pressure in the test chamber. (1) The negative pressure ensures that any air leakage results in air movement from the chamber into the dissemination...than the dissemination compartment. This result is to be expected because random Brownian motion of the disseminated vapor molecules does not permit

  16. 40 CFR 60.8 - Performance tests.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Performance tests. 60.8 Section 60.8... PERFORMANCE FOR NEW STATIONARY SOURCES General Provisions § 60.8 Performance tests. (a) Except as specified in... conduct performance test(s) and furnish the Administrator a written report of the results of such...

  17. Human performance data collected in a virtual environment

    Directory of Open Access Journals (Sweden)

    Mashrura Musharraf

    2017-12-01

    Full Text Available This data article describes the experimental data used in the research article “Incorporating individual differences in human reliability analysis: an extension to the virtual experimental technique” (Musharraf et al., 2017 [1]. The article provides human performance data for 36 individuals collected using a virtual environment. Each participant was assigned to one of two groups for training: 1 G1: high level training and 2 G2: low level training. Participants’ performance was tested in 4 different virtual scenarios with different levels of visibility and complexity. Several performance metrics of the participants were recorded during each scenario. The metrics include: time to muster, time spent running, interaction with fire doors and watertight doors, interaction with hazards, and reporting at different muster locations.

  18. Human performance data collected in a virtual environment.

    Science.gov (United States)

    Musharraf, Mashrura; Smith, Jennifer; Khan, Faisal; Veitch, Brian; MacKinnon, Scott

    2017-12-01

    This data article describes the experimental data used in the research article "Incorporating individual differences in human reliability analysis: an extension to the virtual experimental technique" (Musharraf et al., 2017) [1]. The article provides human performance data for 36 individuals collected using a virtual environment. Each participant was assigned to one of two groups for training: 1) G1: high level training and 2) G2: low level training. Participants' performance was tested in 4 different virtual scenarios with different levels of visibility and complexity. Several performance metrics of the participants were recorded during each scenario. The metrics include: time to muster, time spent running, interaction with fire doors and watertight doors, interaction with hazards, and reporting at different muster locations.

  19. Radon detection system, design, test and performance

    International Nuclear Information System (INIS)

    Balcazar, M.; Chavez, A.; Pina-Villalpando, G.; Navarrete, M.

    1999-01-01

    A portable radon detection system (α-Inin) has been designed and constructed for using it in adverse environmental conditions where humidity, temperature and chemical vaporous are present. The minimum integration time is in periods of 15 min during 41 days. A 12 V battery and a photovoltaic module allow the α-Inin autonomy in field measurements. Data is collected by means of a laptop computer where data processing and α-Inin programming are carried out. α-Inin performance was simultaneously tested in a controlled radon chamber, together with a commercial α-Meter

  20. Operational Based Vision Assessment Automated Vision Test Collection User Guide

    Science.gov (United States)

    2017-05-15

    AFRL-SA-WP-SR-2017-0012 Operational Based Vision Assessment Automated Vision Test Collection User Guide Elizabeth Shoda, Alex...June 2015 – May 2017 4. TITLE AND SUBTITLE Operational Based Vision Assessment Automated Vision Test Collection User Guide 5a. CONTRACT NUMBER... automated vision tests , or AVT. Development of the AVT was required to support threshold-level vision testing capability needed to investigate the

  1. Generating pseudo test collections for learning to rank scientific articles

    NARCIS (Netherlands)

    Berendsen, R.; Tsagkias, M.; de Rijke, M.; Meij, E.

    2012-01-01

    Pseudo test collections are automatically generated to provide training material for learning to rank methods. We propose a method for generating pseudo test collections in the domain of digital libraries, where data is relatively sparse, but comes with rich annotations. Our intuition is that

  2. Stereotype Threat, Test Anxiety, and Mathematics Performance

    Science.gov (United States)

    Tempel, Tobias; Neumann, Roland

    2014-01-01

    We investigated the combined effects of stereotype threat and trait test anxiety on mathematics test performance. Stereotype threat and test anxiety interacted with each other in affecting performance. Trait test anxiety predicted performance only in a diagnostic condition that prevented stereotype threat by stereotype denial. A state measure of…

  3. Operator performance in non-destructive testing: A study of operator performance in a performance test

    Energy Technology Data Exchange (ETDEWEB)

    Enkvist, J.; Edland, A.; Svenson, Ola [Stockholm Univ. (Sweden). Dept. of Psychology

    2000-05-15

    In the process industries there is a need of inspecting the integrity of critical components without disrupting the process. Such in-service inspections are typically performed with non-destructive testing (NDT). In NDT the task of the operator is to (based on diagnostic information) decide if the component can remain in service or not. The present study looks at the performance in NDT. The aim is to improve performance, in the long run, by exploring the operators' decision strategies and other underlying factors and to this way find out what makes some operators more successful than others. Sixteen operators performed manual ultrasonic inspections of four test pieces with the aim to detect (implanted) cracks. In addition to these performance demonstration tests (PDT), the operators performed independent ability tests and filled out questionnaires. The results show that operators who trust their gut feeling more than the procedure (when the two come to different results) and that at the same time have a positive attitude towards the procedure have a higher PDT performance. These results indicate the need for operators to be motivated and confident when performing NDT. It was also found that the operators who performed better rated more decision criteria higher in the detection phase than the operators who performed worse. For characterizing it was the other way around. Also, the operators who performed better used more time, both detecting and characterizing, than the operators who performed worse.

  4. Operator performance in non-destructive testing: A study of operator performance in a performance test

    International Nuclear Information System (INIS)

    Enkvist, J.; Edland, A.; Svenson, Ola

    2000-05-01

    In the process industries there is a need of inspecting the integrity of critical components without disrupting the process. Such in-service inspections are typically performed with non-destructive testing (NDT). In NDT the task of the operator is to (based on diagnostic information) decide if the component can remain in service or not. The present study looks at the performance in NDT. The aim is to improve performance, in the long run, by exploring the operators' decision strategies and other underlying factors and to this way find out what makes some operators more successful than others. Sixteen operators performed manual ultrasonic inspections of four test pieces with the aim to detect (implanted) cracks. In addition to these performance demonstration tests (PDT), the operators performed independent ability tests and filled out questionnaires. The results show that operators who trust their gut feeling more than the procedure (when the two come to different results) and that at the same time have a positive attitude towards the procedure have a higher PDT performance. These results indicate the need for operators to be motivated and confident when performing NDT. It was also found that the operators who performed better rated more decision criteria higher in the detection phase than the operators who performed worse. For characterizing it was the other way around. Also, the operators who performed better used more time, both detecting and characterizing, than the operators who performed worse

  5. Ecotoxicological testing of performance fluids

    International Nuclear Information System (INIS)

    Kallqvist, T.

    1990-05-01

    The report deals with a project comprising the testing of drilling fluids concerning ecotoxicology, biological degradation, and toxicity. Two types of drilling fluids were tested for toxic effects on marine algae and biological degradability. A fluid based on mineral oil was readily degradable (98% DOC removal in 28 days) while an ether based oil degraded more slowly (56% DOC removal in 28 days). The toxicity of both fluids was tested after emulsification of the oils in water and separating the oil and water phase after equilibration. The EC 50 values obtained with this approach were 8.15 g/l for the oil based fluid and 116 g/l for the ether fluid. 9 figs., 8 tabs

  6. Performance of a New HPV Cervi-Collect Collection and Transportation Kit

    Directory of Open Access Journals (Sweden)

    M. Chernesky

    2012-01-01

    Full Text Available Background. Liquid-based Pap (L-Pap media are used for Pap and human papillomavirus (HPV testing. Objectives. To compare RealTime High Risk (HR HPV testing of a new collection kit (Cervi-Collect and PreservCyt L-Pap specimens. To determine ease of use and safety of Cervi-Collect. Methods. L-Pap samples (n=203 were tested with HC2 and RealTime HR HPV and Cervi-Collect with RealTime HR HPV. Discordant samples were genotyped. Results. L-Pap and Cervi-Collect specimens tested by RealTime HR HPV showed 93.1% agreement (Kappa 0.86. RealTime HR HPV and HC2 on L-Pap had 90.3% agreement (Kappa 0.80. RealTime HR HPV on Cervi-Collect and HC2 on L-Pap showed 88.2% agreement (Kappa 0.76. Sixteen of 21 samples which were HC2 negative and RealTime HR HPV positive on L-Pap or Cervi-Collect contained HR HPV genotypes. Eleven healthcare collectors were in strong agreement on a usability and safety questionnaire. Conclusion. Cervi-Collect samples were easy to collect and showed strong agreement with L-Pap samples tested with RealTime HR HPV or HC2.

  7. Developing a Test Collection for the Evaluation of Integrated Search

    DEFF Research Database (Denmark)

    Lykke, Marianne; Larsen, Birger; Lund, Haakon

    2010-01-01

    he poster discusses the characteristics needed in an information retrieval (IR) test collection to facilitate the evaluation of integrated search, i.e. search across a range of different sources but with one search box and one ranked result list, and describes and analyses a new test collection c...... assessments. The test collection may be used for systems- as well as user-oriented evaluation.......he poster discusses the characteristics needed in an information retrieval (IR) test collection to facilitate the evaluation of integrated search, i.e. search across a range of different sources but with one search box and one ranked result list, and describes and analyses a new test collection...... constructed for this purpose. The test collection consists of approx. 18,000 monographic records, 160,000 papers and journal articles in PDF and 275,000 abstracts with a varied set of metadata and vocabularies from the physics domain, 65 topics based on real work tasks and corresponding graded relevance...

  8. 78 FR 60287 - Agency Information Collection Activities; Proposed Collection; Comment Request; Testing...

    Science.gov (United States)

    2013-10-01

    ... communication strategies, messages, and labels. These communications will aim to improve public understanding of... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-1164] Agency Information Collection Activities; Proposed Collection; Comment Request; Testing Communications on...

  9. 75 FR 51271 - Agency Information Collection Activities; Proposed Collection; Comment Request; Testing...

    Science.gov (United States)

    2010-08-19

    ... communication strategies, messages, and labels. These communications will aim to improve public understanding of... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0420] Agency Information Collection Activities; Proposed Collection; Comment Request; Testing Communications on...

  10. 75 FR 39952 - Agency Information Collection Activities; Proposed Collection; Comment Request; Testing...

    Science.gov (United States)

    2010-07-13

    ... communications will aim to improve public understanding of the risks and benefits of using medical devices and... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0344] Agency Information Collection Activities; Proposed Collection; Comment Request; Testing Communications on...

  11. Perceived collective teacher efficacy in low performing schools

    African Journals Online (AJOL)

    Education Management and Leadership, School for Professional Studies in ... enhance collective teacher efficacy, the challenge of low-performing schools ... Collective teacher efficacy, therefore, involves the combined perceptions of ... because greater efficacy leads to greater effort and ... One of the strategies for sharing.

  12. ACER Chemistry Test Item Collection (ACER CHEMTIC Year 12 Supplement).

    Science.gov (United States)

    Australian Council for Educational Research, Hawthorn.

    This publication contains 317 multiple-choice chemistry test items related to topics covered in the Victorian (Australia) Year 12 chemistry course. It allows teachers access to a range of items suitable for diagnostic and achievement purposes, supplementing the ACER Chemistry Test Item Collection--Year 12 (CHEMTIC). The topics covered are: organic…

  13. Integrated Performance Testing Workshop, Modules 6 - 11

    Energy Technology Data Exchange (ETDEWEB)

    Leach, Janice; Torres, Teresa M.

    2012-10-01

    These modules cover performance testing of: Interior Detection Systems; Access Controls; Exterior Detection Systems; Video Assessment Systems; SNM / Contraband Detection Systems; Access Delay Elements

  14. Incremental exercise test performance with and without a respiratory ...

    African Journals Online (AJOL)

    Incremental exercise test performance with and without a respiratory gas collection system. ... PROMOTING ACCESS TO AFRICAN RESEARCH ... Industrial- type mask wear is thought to impair exercise performance through increased respiratory dead space, flow ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  15. FY 2000 report on the survey of the project on field tests on the introduction of high performance industrial furnaces. Analysis/evaluation of the collected data; 2000 nendo koseino kogyoro donyu field test jigyo chosa hokokusho. Shushu data kaiseki hyoka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    For the purpose of achieving the target of reduction in CO2 regarded as substance causing global warming which was agreed at COP3, the study has been made since FY 1993 on 'the development of high performance industrial furnaces (regenerative combustion furnace using heat storage type burner for realization of high temperature air combustion).' By applying the good results obtained, a field test project for introduction of high performance industrial furnace has been implemented for three years (FY 1998 - FY 2000) to confirm the actual performance, reliability, etc. Collection/arrangement were made mainly of the data obtained in this field test project for the introduction of high performance industrial furnaces in each fiscal year (1998, 1999 and 2000), and verification/evaluation and arrangement were made. In this R and D, energy conservation was achieved at a rate of more than 30% of the target. Also about NOx, the result was obtained that the NOx by energy saving can be reduced 50% in almost all kinds of furnace if adding the reduction amount in emission amount and the reduction amount by high temperature air combustion. About the quality, the good result was obtained. Downsizing was conducted in approximately 10 examples. (NEDO)

  16. FY 2000 report on the survey of the project on field tests on the introduction of high performance industrial furnaces. Analysis/evaluation of the collected data; 2000 nendo koseino kogyoro donyu field test jigyo chosa hokokusho. Shushu data kaiseki hyoka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    For the purpose of achieving the target of reduction in CO2 regarded as substance causing global warming which was agreed at COP3, the study has been made since FY 1993 on 'the development of high performance industrial furnaces (regenerative combustion furnace using heat storage type burner for realization of high temperature air combustion).' By applying the good results obtained, a field test project for introduction of high performance industrial furnace has been implemented for three years (FY 1998 - FY 2000) to confirm the actual performance, reliability, etc. Collection/arrangement were made mainly of the data obtained in this field test project for the introduction of high performance industrial furnaces in each fiscal year (1998, 1999 and 2000), and verification/evaluation and arrangement were made. In this R and D, energy conservation was achieved at a rate of more than 30% of the target. Also about NOx, the result was obtained that the NOx by energy saving can be reduced 50% in almost all kinds of furnace if adding the reduction amount in emission amount and the reduction amount by high temperature air combustion. About the quality, the good result was obtained. Downsizing was conducted in approximately 10 examples. (NEDO)

  17. Project W-049H Collection System Acceptance Test

    International Nuclear Information System (INIS)

    Buckles, D.I.

    1994-01-01

    The Acceptance Test Procedure (ATP) Program for Project W-049H covers the following activities: Disposal system, Collection system, Instrumentation and control system. Each activity has its own ATP. The purpose of the ATPs is to verify that the systems have been constructed in accordance with the construction documents and to demonstrate that the systems function as required by the Project criteria. This ATP has been prepared to demonstrate that the Collection System Instrumentation functions as required by project criteria

  18. Hardware support for collecting performance counters directly to memory

    Science.gov (United States)

    Gara, Alan; Salapura, Valentina; Wisniewski, Robert W.

    2012-09-25

    Hardware support for collecting performance counters directly to memory, in one aspect, may include a plurality of performance counters operable to collect one or more counts of one or more selected activities. A first storage element may be operable to store an address of a memory location. A second storage element may be operable to store a value indicating whether the hardware should begin copying. A state machine may be operable to detect the value in the second storage element and trigger hardware copying of data in selected one or more of the plurality of performance counters to the memory location whose address is stored in the first storage element.

  19. Performance Testing of Download Services of COSMC

    Directory of Open Access Journals (Sweden)

    Jiří Horák

    2013-11-01

    Full Text Available The paper presents results of performance tests of download services of Czech Office of Surveying, Mapping and Cadastre according to INSPIRE  requirements. Methodology of testing is explained, including monitoring performance  of reference servers. 26 millions of random requests were generated for each monitored operation, layer and coordinate system. The temporal development of performance indicators are analyzed and discussed. Results of performance tests approve the compliance with INSPIRE qualitative requirements for download services. All monitored services satisfy requirements of latency, capacity and availability. The latency and availability requirements are fulfilled with an abundant reserve. No problems in structure and content of responses were detected.

  20. RUSSIAN FINANCIAL MARKET AND COLLECTIVE INVESTMENT INSTITUTION PERFORMANCE PROBLEMS

    Directory of Open Access Journals (Sweden)

    V. B. Tchernikov

    2012-01-01

    Full Text Available Collective investment is practiced widely in the world, since considerable funds may be accumulated in this way, the risks being born by all the investors. In Russia, there are certain problems that do not make it possible to properly use the collective investment’s potential. The problems are described in detail and on basis of this analysis it is shown how current difficulties in the finance sphere could be overcome. Solution of performance problems faced by collective investment institutions in Russia depends both on the ways venture companies develop themselves and the rate market environment regulation mechanism is updated by the state.

  1. Corrosion performance tests for reinforcing steel in concrete : test procedures.

    Science.gov (United States)

    2009-09-01

    The existing test method to assess the corrosion performance of reinforcing steel embedded in concrete, mainly : ASTM G109, is labor intensive, time consuming, slow to provide comparative results, and often expensive. : However, corrosion of reinforc...

  2. Vitrification Facility integrated system performance testing report

    International Nuclear Information System (INIS)

    Elliott, D.

    1997-01-01

    This report provides a summary of component and system performance testing associated with the Vitrification Facility (VF) following construction turnover. The VF at the West Valley Demonstration Project (WVDP) was designed to convert stored radioactive waste into a stable glass form for eventual disposal in a federal repository. Following an initial Functional and Checkout Testing of Systems (FACTS) Program and subsequent conversion of test stand equipment into the final VF, a testing program was executed to demonstrate successful performance of the components, subsystems, and systems that make up the vitrification process. Systems were started up and brought on line as construction was completed, until integrated system operation could be demonstrated to produce borosilicate glass using nonradioactive waste simulant. Integrated system testing and operation culminated with a successful Operational Readiness Review (ORR) and Department of Energy (DOE) approval to initiate vitrification of high-level waste (HLW) on June 19, 1996. Performance and integrated operational test runs conducted during the test program provided a means for critical examination, observation, and evaluation of the vitrification system. Test data taken for each Test Instruction Procedure (TIP) was used to evaluate component performance against system design and acceptance criteria, while test observations were used to correct, modify, or improve system operation. This process was critical in establishing operating conditions for the entire vitrification process

  3. Test Collections for Patent-to-Patent Retrieval and Patent Map Generation in NTCIR-4 Workshop

    OpenAIRE

    Fujii, Atsushi; Iwayama, Makoto; Kando, Noriko

    2004-01-01

    This paper describes the Patent Retrieval Task in the Fourth NTCIR Workshop, and the test collections produced in this task. We perform the invalidity search task, in which each participant group searches a patent collection for the patents that can invalidate the demand in an existing claim. We also perform the automatic patent map generation task, in which the patents associated with a specific topic are organized in a multi-dimensional matrix.

  4. The Effects of Humor on Test Anxiety and Test Performance

    Science.gov (United States)

    Tali, Glenda

    2017-01-01

    Testing in an academic setting provokes anxiety in all students in higher education, particularly nursing students. When students experience high levels of anxiety, the resulting decline in test performance often does not represent an accurate assessment of students' academic achievement. This quantitative, experimental study examined the effects…

  5. A Comparative Analysis of the Performance of Collective Investment Institutions

    OpenAIRE

    Carmen-Pilar Mart¨ª-Ballester

    2012-01-01

    Pension plans and mutual funds represent a substantial part of the welfare systems in both Europe and Spain. One of the most important factors in the choice of a plan or fund is its performance, since if high returns are obtained; the participant will receive higher payments when the contingency covered by the plan occurs or when the investors of the mutual funds recover their investments. The main objective of this paper is therefore to analyze the performance of Spanish collective investmen...

  6. Project W-049H collection system Acceptance Test Procedure

    International Nuclear Information System (INIS)

    Carrigan, M.C.

    1994-01-01

    The purpose of this Acceptance Test Procedure (ATP) for the Project W-049H, Treated Effluent Disposal Facility, is to verify that the collection system equipment installed as Pump Station No. 1 (225-W) and Pump Station No. 2 (225-E) have been installed in accordance with the design documents and function as required by the project criteria. This will be a wet test with potable water being introduced into the pump pits to test for leakage. Potable water will also be employed in the testing of the pumps and related mechanical equipment. All Instrument and Control equipment related to the pump stations will be checked electronically with simulated inputs/outputs when actual input/output signals are unavailable. Water from Pump Station 1 will be moved through the TEDF piping system and discharged into the disposal ponds. This will check the proper function of the air/vac valves not tested during construction, and the automated samplers

  7. Integrated Performance Testing for Nonproliferation Support Project

    Energy Technology Data Exchange (ETDEWEB)

    Johns, Russell; Bultz, Garl Alan; Byers, Kenneth R.; Yaegle, William

    2013-08-20

    The objective of this workshop is to provide participants with training in testing techniques and methodologies for assessment of the performance of: Physical Protection system elements; Material Control and Accounting (MC&A) system elements.

  8. Summary of functional and performance test procedures

    DEFF Research Database (Denmark)

    Mitzel, Jens; Gülzow, Erich; Friedrich, K. Andreas

    Different Test Modules (TM) are defined for the functional and performance characterization of a PEMFC stack. The master document TM2.00 defines requirements and methodology for parameter variation, stability and data acquisition.......Different Test Modules (TM) are defined for the functional and performance characterization of a PEMFC stack. The master document TM2.00 defines requirements and methodology for parameter variation, stability and data acquisition....

  9. Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  10. Severe fuel-damage scoping test performance

    International Nuclear Information System (INIS)

    Gruen, G.E.; Buescher, B.J.

    1983-01-01

    As a result of the Three Mile Island Unit-2 (TMI-2) accident, the Nuclear Regulatory Commission has initiated a severe fuel damage test program to evaluate fuel rod and core response during severe accidents similar to TMI-2. The first test of Phase I of this series has been successfully completed in the Power Burst Facility at the Idaho National Engineering Laboratory. Following the first test, calculations were performed using the TRAC-BD1 computer code with actual experimental boundary conditions. This paper discusses the test conduct and performance and presents the calculated and measured test bundle results. The test resulted in a slow heatup to 2000 K over about 4 h, with an accelerated reaction of the zirconium cladding at temperatures above 1600 K in the lower part or the bundle and 2000 K in the upper portion of the bundle

  11. Work zone performance measures pilot test.

    Science.gov (United States)

    2011-04-01

    Currently, a well-defined and validated set of metrics to use in monitoring work zone performance do not : exist. This pilot test was conducted to assist state DOTs in identifying what work zone performance : measures can and should be targeted, what...

  12. RHIC sextant test: Accelerator systems and performance

    Energy Technology Data Exchange (ETDEWEB)

    Pilat, F.; Trbojevic, D.; Ahrens, L. [and others

    1997-08-01

    One sextant of the RHIC Collider was commissioned in early 1997 with beam. We describe here the performance of the accelerator systems, instrumentation subsystems and application software. We also describe a ramping test without beam that took place after the commissioning with beam. Finally, we analyze the implications of accelerator systems performance and their impact on the planning for RHIC installation and commissioning.

  13. RHIC sextant test: Accelerator systems and performance

    International Nuclear Information System (INIS)

    Pilat, F.; Trbojevic, D.; Ahrens, L.

    1997-01-01

    One sextant of the RHIC Collider was commissioned in early 1997 with beam. We describe here the performance of the accelerator systems, instrumentation subsystems and application software. We also describe a ramping test without beam that took place after the commissioning with beam. Finally, we analyze the implications of accelerator systems performance and their impact on the planning for RHIC installation and commissioning

  14. Performance of smokeless gasoline fire test facility

    International Nuclear Information System (INIS)

    Griffin, J.F.; Watkins, R.A.

    1978-01-01

    Packaging for radioactive materials must perform satisfactorily when subjected to temperatures simulating an accident involving a fire. The new thermal test facility has proved to be a reliable method for satisfactorily performing the required test. The flame provides sufficient heat to assure that the test is valid, and the temperature can be controlled satisfactorily. Also, the air and water mist systems virtually eliminate any smoke and thereby exceed the local EPA requirements. The combination of the two systems provides an inexpensive, low maintenance technique for elimination of the smoke plume

  15. Feature test report for the Small Debris Collection and Packaging System

    International Nuclear Information System (INIS)

    Brisbin, S.A.

    1995-01-01

    The Spent Nuclear Fuel Equipment Engineering group performed feature testing of the Small Debris Collection and Packaging System (SDCPS) in the 305 Cold Test Facility from January 30, 1995, to February 1, 1995. Feature testing of the Small Debris Collection and Packaging System (SDCPS) was performed for the following reasons: To assess the feasibility of using ''drop-out'' vessels to collect small debris (<2.5 cm) in MK-II fuel canisters while transferring sludge to the Weasel Pit. To evaluate system performance under conditions similar to those in the K-Basins (e.g. submerged under 4.9 meters of water and operated with long handled tools) while using a surrogate sludge mixed with debris. To determine if canister weight could be used to predict the volume of sludge and/or debris contained within the canisters during system operation

  16. NNWSI waste form performance test development

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.

    1984-01-01

    A test method has been developed to measure the release of radionuclides from the waste package under simulated NNWSI repository conditions, and to provide information concerning materials interactions that may occur in the repository. Data from 13 weeks of unsaturated testing are discussed and compared to that from a 13-week analog test. The data indicate that the waste form test is capable of producing consistent, reproducible results that will be useful in evaluating the role of the waste in the long-term performance of the repository. 6 references, 3 figures

  17. Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test

    International Nuclear Information System (INIS)

    Bae, Kyoo Whan; Song, Jin Ho; Chung, Young Jong; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring in the downcomer with limited budget and time, the separate effects test focusing on this region is considered to be effective and the conceptual test facility based on this recommended. For this test facility the test initial and boundary conditions are developed using the CEFLASH-4AS/REM analysis results that will be used as input for the preliminary test requirements. The final test requirements will be developed through the further discussions with the test performance group. (Author). 10 refs., 18 tabs., 4 figs

  18. BRAINSTORMING - EVIDENCE COLLECTION TECHNIQUES IN THE PERFORMANCE AUDIT

    OpenAIRE

    Emilia VASILE; Ion CROITORU

    2010-01-01

    Discussion groups are among the most common research facilities for the collection of evidence used in performance auditing, characterized by flexibility, because the participants can express their own answers, express opinions and responses of other group members qualify. Brainstorming is a variant of discussion groups aims to generate ideas or solutions and individualized approach in that the mediator has a minimal involvement. This recommendation focuses on participants to make suggestions...

  19. Test plan for dig-face characterization performance testing

    International Nuclear Information System (INIS)

    Josten, N.E.

    1993-09-01

    The dig-face characterization concept has been under development at the Idaho National Engineering Laboratory (INEL) since FY 1992 through the support of the Buried Waste Integrated Demonstration Program. A Dig-face Characterization System conducts continuous subsurface characterization simultaneously with retrieval of hazardous and radioactive waste from buried waste sites. The system deploys multiple sensors at the retrieval operation dig-face and collects data that provide a basis for detecting, locating, and identifying hazardous conditions before they are disturbed by the retrieval equipment. This test plan describes initial efforts to test the dig-face characterization concept at the INEL Cold Test Pit using a simplified prototype apparatus and off-the-shelf sensors. The Cold Test Pit is a simulated waste site containing hazardous and radioactive waste surrogates at known locations. Testing will be directed toward three generic characterization problems: metal detection, plume detection, and radioactive source detection. The prototype apparatus will gather data using magnetometers, a ground conductivity meter, a trace gas analyzer, and a gamma ray sensor during simulated retrieval of the surrogate waste materials. The data acquired by a dig-face characterization system are unique because of the high precision, high data density, and multiple viewpoints attainable through the dig-face deployment approach. The test plan establishes procedures for collecting and validating a representative dig-face characterization data set. Analysis of these data will focus on developing criteria for predicting the depth, location, composition, and other characteristics of the surrogate waste materials. If successful, this proof-of-concept exercise will provide a foundation for future development of a fully-operational system that is capable of operating on an actual waste site

  20. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  1. Performance testing of extremity dosimeters, Study 2

    International Nuclear Information System (INIS)

    Harty, R.; Reece, W.D.; Hooker, C.D.

    1990-04-01

    The Health Physics Society Standards Committee (HPSSC) Working Group on Performance Testing of Extremity Dosimeters has issued a draft of a proposed standard for extremity dosimeters. The draft standard proposes methods to be used for testing dosimetry systems that determine occupational radiation dose to the extremities and the performance criterion used to determine compliance with the standard. Pacific Northwest Laboratory (PNL) has conducted two separate evaluations of the performance of extremity dosimeter processors to determine the appropriateness of the draft standard, as well as to obtain information regarding the performance of extremity dosimeters. Based on the information obtained during the facility visits and the results obtained from the performance testing, it was recommended that changes be made to ensure that the draft standard is appropriate for extremity dosimeters. The changes include: subdividing the mixture category and the beta particle category; eliminating the neutron category until appropriate flux-to-dose equivalent conversion factors are derived; and changing the tolerance level for the performance criterion to provide consistency with the performance criterion for whole body dosimeters, and to avoid making the draft standard overly difficult for processors of extremity dosimeters to pass. 20 refs., 10 figs., 6 tabs

  2. Development of turbopump cavitation performance test facility and the test of inducer performance

    International Nuclear Information System (INIS)

    Sohn, Dong Kee; Kim, Chun Tak; Yoon, Min Soo; Cha, Bong Jun; Kim, Jin Han; Yang, Soo Seok

    2001-01-01

    A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar, rotational speed - 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification

  3. Testing prospect theory in students’ performance

    OpenAIRE

    Pérez Galdón, Patricia; Nicolau, Juan Luis

    2013-01-01

    This paper tests the existence of ‘reference dependence’ and ‘loss aversion’ in students’ academic performance. Accordingly, achieving a worse than expected academic performance would have a much stronger effect on students’ (dis)satisfaction than obtaining a better than expected grade. Although loss aversion is a well-established finding, some authors have demonstrated that it can be moderated – diminished, to be precise–. Within this line of research, we also examine whether the students’ e...

  4. Load responsive multilayer insulation performance testing

    International Nuclear Information System (INIS)

    Dye, S.; Kopelove, A.; Mills, G. L.

    2014-01-01

    Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI

  5. Load responsive multilayer insulation performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Dye, S.; Kopelove, A. [Quest Thermal Group, 6452 Fig Street Suite A, Arvada, CO 80004 (United States); Mills, G. L. [Ball Aerospace and Technologies Corp, 1600 Commerce Street, Boulder, CO 80301 (United States)

    2014-01-29

    Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.

  6. 40 CFR 1065.520 - Pre-test verification procedures and pre-test data collection.

    Science.gov (United States)

    2010-07-01

    ... corrective action does not resolve the deficiency, you may request to use the contaminated system as an... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Pre-test verification procedures and pre-test data collection. 1065.520 Section 1065.520 Protection of Environment ENVIRONMENTAL PROTECTION...

  7. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false OTC test sample collection systems for drugs of abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology...

  8. Testing for Distortions in Performance Measures

    DEFF Research Database (Denmark)

    Sloof, Randolph; Van Praag, Mirjam

    2015-01-01

    Distorted performance measures in compensation contracts elicit suboptimal behavioral responses that may even prove to be dysfunctional (gaming). This paper applies the empirical test developed by Courty and Marschke (Review of Economics and Statistics, 90, 428-441) to detect whether the widely...

  9. Testing for Distortions in Performance Measures

    DEFF Research Database (Denmark)

    Sloof, Randolph; Van Praag, Mirjam

    Distorted performance measures in compensation contracts elicit suboptimal behavioral responses that may even prove to be dysfunctional (gaming). This paper applies the empirical test developed by Courty and Marschke (2008) to detect whether the widely used class of Residual Income based performa...

  10. Drop Performance Test of CRDMs for JRTR

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Myoung-Hwan; Cho, Yeong-Garp; Chung, Jong-Ha [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Jung-Hyun [POSCO Plandtec Co. Ltd, Ulsan (Korea, Republic of); Lee, Kwan-Hee [RIST, Pohang (Korea, Republic of)

    2015-10-15

    The drop test results of CRDMs with AC-type electromagnet show that the initial delay times are not satisfied with the requirement, 0.15 seconds. After the replacement of the electromagnet from AC-type to DCtype, the drop times of CARs and accelerations due to the impact of moving parts are satisfied with all requirements. As a result, it is found that four CRDMs to be installed at site have a good drop performance, and meet all performance requirements. A control rod drive mechanism (CRDM) is a device to control the position of a control absorber rod (CAR) in the core by using a stepping motor which is commanded by the reactor regulating system (RRS) to control the reactivity during the normal operation of the reactor. The top-mounted CRDM driven by the stepping motor for Jordan Research and Training Reactor (JRTR) has been developed in KAERI. The CRDM for JRTR has been optimized by the design improvement based on that of the HANARO. It is necessary to verify the performances such as the stepping, drop, endurance, vibration, seismic and structural integrity for active components. Especially, the CAR drop curves are important data for the safety analysis. This paper describes the test results to demonstrate the drop performances of a prototype and 4 CRDMs to be installed at site. The tests are carried out at a test rig simulating the actual reactor's conditions.

  11. SIMS Prototype System 4: performance test report

    Energy Technology Data Exchange (ETDEWEB)

    1978-10-09

    The results obtained during testing of a self-contained, preassembled air type solar system, designed for installation remote from the dwelling, to provide space heating and hot water are presented. Data analysis is included which documents the system performance and verifies the suitability of SIMS Prototype System 4 for field installation.

  12. Performance tests for integral reactor nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Dong-Seong; Yim, Jeong-Sik; Lee, Chong-Tak; Kim, Han-Soo; Koo, Yang-Hyun; Lee, Byung-Ho; Cheon, Jin-Sik; Oh, Je-Yong

    2006-02-15

    An integral type reactor SMART plans to utilize metallic Zr-U fuel which is Zr-based alloy with 34{approx}38 wt% U. In order to verify the technologies for the design and manufacturing of the fuel and get a license, performance tests were carried out. Experimental Fuel Assembly (EFA) manufactured in KAERI is being successfully irradiated in the MIR reactor of RIAR from September 4 2004, and it has achieved burnup of 0.21 g/cc as of January 25 2006. Thermal properties of irradiated Zr-U fuel were measured. Up to the phase transformation temperature, thermal diffusivity increased linearly in proportion to temperature. However its dependence on the burnup was not significant. RIA tests with 4 unirradiated Zr-U fuel rods were performed in Kurchatov Institute to establish a safety criterion. In the case of the un-irradiated Zr-U fuel, the energy deposition during the control rod ejection accident should be less than 172 cal/g to prevent the failure accompanying fuel fragmentation and dispersal. Finally the irradiation tests of fuel rods have been performed at HANARO. The HITE-2 test was successfully completed up to a burnup of 0.31 g/cc. The HITE-3 test began in February 2004 and will be continued up to a target burnup of 0.6 g/cc.

  13. Automating the simulator testing and data collection process

    Energy Technology Data Exchange (ETDEWEB)

    Magi, T.; Dimitri-Hakim, R. [L-3 Communications MAPPS Inc., Montreal, Quebec (Canada)

    2012-07-01

    Scenario-based training is a key process in the use of Full Scope Simulators (FSS) for operator training. Scenario-based training can be defined as any set of simulated plant operations performed with a specific training objective in mind. In order to meet this training objective, the ANSI/ANS-3.5-2009 standard requires that certain simulator training scenarios be tested to ensure that they reproduce the expected plant responses, that all plant procedures can be followed, and that scenario-based training objectives can be met. While malfunction testing provided a narrow view of the simulator performance revolving around the malfunction itself, scenario testing provides a broader, overall view. The concept of instructor validation of simulator scenarios to be used for training and evaluation, and oversight of simulator performance during the validation process, work hand-in-hand. This is where Scenario-Based Testing comes into play. With the description of Scenario-Based Testing (SBT) within Nuclear Energy Institute NEI 09-09 white paper and within the ANSI/ANS-3.5-2009 standard, the industry now has a way forward that reduces the regulatory uncertainty. Together, scenario-based testing and scenario-based training combine to produce better simulators which in turn can be used to more effectively and efficiently train new and existing power plant operators. However, they also impose a significant data gathering and analysis burden on FSS users. L-3 MAPPS Orchid Instructor Station (Orchid IS) facilitates this data gathering and analysis by providing features that automate this process with a simple, centralized, easy to use interface. (author)

  14. Motivation and Test Anxiety in Test Performance across Three Testing Contexts: The CAEL, CET, and GEPT

    Science.gov (United States)

    Cheng, Liying; Klinger, Don; Fox, Janna; Doe, Christine; Jin, Yan; Wu, Jessica

    2014-01-01

    This study examined test-takers' motivation, test anxiety, and test performance across a range of social and educational contexts in three high-stakes language tests: the Canadian Academic English Language (CAEL) Assessment in Canada, the College English Test (CET) in the People's Republic of China, and the General English Proficiency Test (GEPT)…

  15. MFTF test coil construction and performance

    International Nuclear Information System (INIS)

    Cornish, D.N.; Zbasnik, J.P.; Leber, R.L.; Hirzel, D.G.; Johnston, J.E.; Rosdahl, A.R.

    1978-01-01

    A solenoid coil, 105 cm inside the 167 cm outside diameter, has been constructed and tested to study the performance of the stabilized Nb--Ti conductor to be used in the Mirror Fusion Test Facility (MFTF) being built at Lawrence Livermore Laboratory. The insulation system of the test coil is identical to that envisioned for MFTF. Cold-weld joints were made in the conductor at the start and finish of each layer; heaters were fitted to some of these joints and also to the conductor at various locations in the winding. This paper gives details of the construction of the coil and the results of the tests carried out to determine its propagation and recovery characteristics

  16. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of Madagascar. Materials and methods: Participants were recruited in a health care center (urban group) and smaller affiliated dispensaries (rural group). They were invited to perform ...

  17. Performance Test of CCTV in a Test Field

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyung Min [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2011-10-15

    On April 12-13, 2010, US President Obama hosted a Nuclear Security Summit in Washington, DC, to enhance international cooperation to prevent nuclear terrorism, an issue which he has identified as the most immediate and extreme threat to global security. The Summit focused on the security of nuclear materials, nonproliferation, disarmament, and peaceful nuclear energy. At the summit, the Republic of Korea was chosen as the host of the next Summit in 2012. This series of events reflects the growing global interest on 'Nuclear Security' and as the host country of the next Nuclear Summit it is the time for Korea to strengthen the physical protection regime for nuclear facilities as a first step of securing its nuclear security capability. KINAC has been operating Test field as a mean of preparing solid backup data for reviewing and revising DBT (Design Basis Threat) and to test components of the conventional physical protection system. CCTV is a key component which is used worldwide for the assessment measure of alarms. In terms of performance test of CCTV, there are several elements such as image quality, coverage and mechanical features (speed of zoom-in-out, capture, angle shift etc.). Speaking of image quality acquired by the CCTV, the quality is subject to resolution, monitor specification, camera housing, camera mounting and lightening. Thus it is clear that performance tests on image quality should consider those factors and vary the factors respectively in order to verify the influence and the interaction among those. Nevertheless due to the restrictions of the current Test field, this paper focuses on the image quality through resolution test under the various lightening conditions

  18. Eurados trial performance test for photon dosimetry

    DEFF Research Database (Denmark)

    Stadtmann, H.; Bordy, J.M.; Ambrosi, P.

    2001-01-01

    Within the framework of the EURADOS Action entitled Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation, trial performance tests for whole-body and extremity personal dosemeters were carried out. Photon, beta and neutron dosemeters were considered....... This paper summarises the results of the whole-body photon dosemeter test. Twenty-six dosimetry services from all EU Member States and Switzerland participated. Twelve different radiation fields were used to simulate various workplace irradiation fields. Dose values from 0.4 mSv to 80 mSv were chosen. From...

  19. Testing Solutions for Adult Film Performers.

    Science.gov (United States)

    Bergman, Zachary R

    2014-01-01

    The majority of the nation's adult films are produced in California, and within California, most production occurs in Los Angeles. In order to regulate that content, the County of Los Angeles passed the Safer Sex in the Adult Film Industry Act (Measure B) by way of referendum in November 2012. Measure B requires that adult film producers wishing to film in Los Angeles County obtain permits from the Los Angeles County Department of Public Health, and it also mandates that adult film performers use condoms while filming and "engaging in anal or vaginal sexual intercourse." Nevertheless, between August 2013 and January 2014, several adult film performers in California tested positive for HIV, and the threat of infection remains. Although Measure B is not the best way forward for Los Angeles County, elements of the ordinance should be incorporated into future legislative efforts. Given the economic ramifications of industry flight due to more localized regulations, this Note concludes that California should pass statewide comprehensive reform. Any such new legislation must treat "independent contractors," the classification generally used for adult film performs, as if they were regular employees. Legislation should also couple mandatory testing mechanisms with provisions granting performers the right to choose whether they use condoms. Finally, legislation must include mechanisms that ensure performers' preferences are not improperly tainted by outside forces and pressures. While there will always be risks associated with the production of adult content, if undertaken, these reforms could significantly mitigate those hazards.

  20. Impact of Group Emotions on Student Collective Action Tendencies, Ties, and Task Performance

    Science.gov (United States)

    Sundararajan, Malavika; Sundararajan, Binod; Manderson, Jill

    2016-01-01

    The authors tested the dynamics of collective action tendencies of student teams when trying to accomplish a shared goal, with a focus on the impact of member ties and team member interaction and emotional responses on team performance. The results show the direct and indirect impacts of both positive and negative group emotions on the student…

  1. Performance test of 100 W linear compressor

    Energy Technology Data Exchange (ETDEWEB)

    Ko, J; Ko, D. Y.; Park, S. J.; Kim, H. B.; Hong, Y. J.; Yeom, H. K. [Korea Institute of Machinery and Materials, Daejeon(Korea, Republic of)

    2013-09-15

    In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.

  2. Performance test of a TMS calorimeter

    International Nuclear Information System (INIS)

    Wild, B.

    1986-10-01

    Performance tests of a first calorimeter module using the room temperature liquid tetramethylsilane (TMS) as active element are described in detail. As absorber planed carbon steel slabs had been used. The charge yield is 70% of that in a very pure sample of the liquid. A long term stability of the signal with a lifetime of half a year has been realized. Experiences are described and the results explained in detail. (orig.) [de

  3. RHIC Sextant Test -- Physics and performance

    International Nuclear Information System (INIS)

    Wei, J.; Fischer, W.; Ahrens, L.

    1997-01-01

    This paper presents beam physics and machine performance results of the Relativistic Heavy Ion Collider (RHIC) Sextant and AGS-to-RHIC (AtR) transfer line during the Sextant Test in early 1997. Techniques used to measure both machine properties (difference orbits, dispersion, and beamline optics) and beam parameters (energy, intensity, transverse and longitudinal emittances) are described. Good agreement was achieved between measured and design lattice optics. The gold ion beam quality was shown to approach RHIC design requirements

  4. Performance tests on the NRPB thermoluminescent dosemeter

    CERN Document Server

    Shaw, K B

    1977-01-01

    Performance tests on the thermoluminescent dosemeter, designed at NRPB for use in the automated personal dosimetry system, are described. An ultra-thin lithium borate dosemeter has been developed for skin absorbed dose measurement. The X-ray, gamma-ray and beta-ray energy response of the dosemeter has been investigated and the angular response for the dosemeter has been examined. The annealing, read-out and stabilisation procedures for the dosemeter are described.

  5. Collection and cultivation methods of Acartia tonsa for toxicity testing

    International Nuclear Information System (INIS)

    Hood, C.A.; Mayo, R.R.

    1995-01-01

    Acartia tonsa were located and collected from Galveston Bay, Texas in June 1995, using plankton nets and transported to the laboratory for culture. After literature searching and laboratory experimentation. A simple reliable method was designed to culture A. tonsa. This method requires a minimum of glassware and supplies. Adult A. tonsa are placed in one gallon bell jars filled with natural seawater. The jars are then maintained in a water bath at a constant temperature. Water changes are conducted twice weekly and organisms are fed daily with a mixture of algae, Skeletonema costatum, isocrysis galbana, and Thalassiosira sp. Gravid females are then isolated in generators for 24 hours to obtain known age neonates. The neonates are maintained up to a specific age and then are used in toxicity tests such as the ''Determination of the Acute Lethal Toxicity to Marine Copepods,'' required in the United Kingdom for all chemicals used for offshore drilling fluid applications

  6. Heating facility for blanket and performance test

    Energy Technology Data Exchange (ETDEWEB)

    Furuya, Kazuyuki; Kuroda, Toshimasa; Enoeda, Mikio; Sato, Satoshi; Hatano, Toshihisa; Takatsu, Hideyuki; Ohara, Yoshihiro [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Hara, Shigemitsu

    1999-03-01

    A design and a fabrication of heating test facility for a mock-up of the blanket module to be installed in International Thermonuclear Experimental Reactor (ITER) have been conducted to evaluate/demonstrate its heat removal performance and structural soundness under cyclic heat loads. To simulate surface heat flux to the blanket module, infrared heating method is adopted so as to heat large surface area uniformly. The infrared heater is used in vacuum environment (10{sup -4} Torr{approx}), and the lamps are cooled by air flowing through an annulus between the lamp and a cover tube made of quartz glass. Elastomer O rings (available to be used up to {approx}300degC) and used for vacuum seal at outer surface of the cover tube. To prevent excessive heating of the O ring, the end part of the cover tube is specially designed including the tube shape, flow path of air and gold coating on the surface of the cover tube to protect the O ring against thermal radiation from glowing tungsten filament. To examine the performance of the facility, steady state and cyclic operation of the infrared heater were conducted using a small-scaled shielding blanket mock-up as a test specimen. The important results are as follows: (1) Heat flux at the surface of the small-scaled mock-up measured by a calorimeter was {approx}0.2 MW/m{sup 2}. (2) A comparison of thermal analysis results and measured temperature responses showed that the small-scaled mock-up had good heat removal performance. (3) Steady state operation and cyclic operation with step response between the rated and zero powers of the infrared heater were successfully performed, and it was confirmed that this heating facility was well-prepared and available for the thermal cyclic test of a blanket module. (author)

  7. Performance Tests for Bubble Blockage Device

    International Nuclear Information System (INIS)

    Ha, Kwang Soon; Wi, Kyung Jin; Park, Rae Joon; Wan, Han Seong

    2014-01-01

    Postulated severe core damage accidents have a high threat risk for the safety of human health and jeopardize the environment. Versatile measures have been suggested and applied to mitigate severe accidents in nuclear power plants. To improve the thermal margin for the severe accident measures in high-power reactors, engineered corium cooling systems involving boiling-induced two-phase natural circulation have been proposed for decay heat removal. A boiling-induced natural circulation flow is generated in a coolant path between a hot vessel wall and cold coolant reservoir. In general, it is possible for some bubbles to be entrained in the natural circulation loop. If some bubbles entrain in the liquid phase flow passage, flow instability may occur, that is, the natural circulation mass flow rate may be oscillated. A new device to block the entraining bubbles is proposed and verified using air-water test loop. To avoid bubbles entrained in the natural circulation flow loop, a new device was proposed and verified using an air-water test loop. The air injection and liquid circulation loop was prepared, and the tests for the bubble blockage devices were performed by varying the geometry and shape of the devices. The performance of the bubble blockage device was more effective as the area ratio of the inlet to the down-comer increased, and the device height decreased. If the device has a rim to generate a vortex zone, the bubbles will be most effectively blocked

  8. Performance testing SPECT systems: Recent developments

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.

    1985-01-01

    A protocol is used to test as many currently available systems as possible, including both rotating gamma camera systems from GE, Siemens, Toshiba, Technicare, Elscint, Philips, Picker, etc, and single/multi slice system such as the Medimatic. This paper indicates changes that have occurred with respect to preliminary results previously published. Reconstructions were performed in a standard manner, using a Ramp filter and without attenuation correction, in order to reduce the effect of differences in software. The Jaszczak phantom was used to assess overall image quality. Tests were performed using the different collimators available. Image quality improved with better spatial resolution, even at the expense of sensitivity. Non-circular orbits, where available, were tested, and resolution was comparing for various positions and directions. With double headed systems, the results obtained were compared to those using a single head alone. Some gain in image quality seems to have been achieved by better uniformity resulting from improved correction circuitry, by the use of non-circular orbits, and from scatter correction. Potential still exists to improve collimator design

  9. Smarter Grid through Collective Intelligence: User Awareness for Enhanced Performance

    Directory of Open Access Journals (Sweden)

    Marcel Macarulla

    2015-02-01

    Full Text Available Purpose – This paper examines the scenario of a university campus, and the impact on energy consumption of the awareness of building managers and users (lecturers, students and administrative staff.Design/methodology/approach – This study draws a comparison between direct fruition of the information by both skilled (building managers and unskilled (users recipients, and the effect of peer pressure and beneficial competition between users in applying the good practices. In fact, the usage of edutainment, implemented by the automatic publication on the Twitter platform of energy consumption data from different users, can promote general users’ awareness on best practices and their effect on energy consumption. In addition, the use of a social network platform allows the interaction between users, sharing experiences and increasing the collective intelligence in the energy efficiency field.Findings – Tests revealed that enhanced awareness helped managers to identify strategies that, if implemented in the whole building, could reduce energy consumption by about 6%. The tests on university users’ awareness hint that the expected energy savings can reach 9%, in addition to the previous 6%. In fact, the measures were implemented in one of the three common rooms, and at building level the total energy consumption decreased by 3.42%, proving that a large deal of energy can be saved by capillary actions targeting society at large. The emerging collective intelligence of the final users ends up having a stronger effect on energy saving than the actions of more educated professionals.Practical implications – The approach used in this paper moved the burden of evolving the energy saving strategies to new scenarios onto the collective intelligence of the users, by connecting the users – and their experiences in new scenarios – using a social network to provide guidelines to other users involved in the same decision processes

  10. DPM PERFORMANCE TESTING USING RASPBERRY PIS

    CERN Document Server

    Regala, M

    2013-01-01

    This is the final report from attending CERN’s Summer Student Programme. The project goal was to do performance testing on the Disk Pool Manager (DPM), a lightweight, reliable, grid-aware storage software used to store and retrieve data produced by CERN’s LHC experiments using the small, low-end ARM powered devices named Raspberry Pis. The idea behind it was to reason if it’s possible to use a cluster of lower-end, under-capable devices to run DPM, and to conclude if it would be more energy efficient than running it on oversized machines, with the same or comparable performance. If this hypothesis was true, the power-hungry machines could be ditched in favour of these small devices, leading to an enormous saving in overall power consumption and hence, overall cost. In this report, I describe what was the initial project goal and intended outcomes, proceeding to explain the underlying technologies used. Afterwards, I’ll explain the setup used, the tests performed, and the conclusions reached. iii

  11. Test gear and measurements a collection of useful and tested circuit design ideas'

    CERN Document Server

    Stewart OBE DLitthc, David

    2013-01-01

    This book provides a clear introduction to test gear in the field of electronics. As well as being a first guide to test gear and its use, the book includes much practical information and reference material for the more experienced electronics enthusiast or student.Based on a collection of feature articles originally published in Electronics - the Maplin Magazine, this work by Danny Stewart is sure to be useful to electronics constructors, students and experimenters alike. Details of all the common (and some not-so-common) items of test gear are included, alongside information regarding its us

  12. Performance tests for instruments measuring radon activity concentration

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Schmidt, V.

    2009-01-01

    Performance tests of electronic instruments measuring the activity concentration of 222 Rn have been carried out with respect to the standard IEC 61577-2. In total, 9 types of instrument operating with ionization chambers or electrostatic collection have been tested for the influence of different climatic and radiological factors on the measurement characteristics. It is concluded that all types of instrument, which are commercially available, are suitable for indoor radon measurements. Because of the dependence on climatic conditions, the outdoor use is partly limited.

  13. Performance testing of a hydrogen heat pipe

    International Nuclear Information System (INIS)

    Alario, J.; Kosson, R.

    1980-01-01

    Test results are presented for a reentrant groove heat pipe with hydrogen working fluid. The heat pipe became operational between 20 and 30 K after a cooldown from 77 K without any difficulty. Steady-state performance data taken over a 19 to 23 K temperature range indicated the following: (1) maximum heat transport capacity 5.4 W-m (2) static wicking height 1.42 cm and (3) overall heat pipe conductance 1.7 W/C. These data agreed remarkably well with extrapolations made from comparable ammonia test results. The maximum heat transport capacity is 9.5% larger than the extrapolated value, but the static wicking height is the same. The overall conductance is 29% of the ammonia value, which is close to the ratio of liquid thermal conductivities (24%). Also, recovery from a completely frozen condition was accomplished within 5 min by simply applying an evaporater heat load of 1.8 W

  14. Performance test of wet type decontamination device

    International Nuclear Information System (INIS)

    Lee, E. P.; Kim, E. G.; Min, D. K.; Jun, Y. B.; Lee, H. K.; Seu, H. S.; Kwon, H. M.; Hong, K.P.

    2003-01-01

    The intervention area located at rear hot cell can be contaminated by hot cell maintenance work. For effective decontamination of the intervention floor a wet type decontamination device was developed. The device was assembled with a brush rotating part, a washing liquid supplying part, an intake part for recovering contaminated liquid and a device moving cart part. The device was made of stainless steel for easy decontamination and corrosion resistance. The function test carried out at intervention area of the PIE facility showed good performance

  15. Performance testing of UK personal dosimetry laboratories

    CERN Document Server

    Marshall, T O

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it...

  16. Performance testing of UK personal dosimetry laboratories

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it are also estimated. (author)

  17. Texas flexible pavements and overlays : year 1 report, test sections, data collection, analyses, and data storage system.

    Science.gov (United States)

    2012-06-01

    This five-year project was initiated to collect materials and pavement performance data on a minimum of 100 highway test sections around the State of Texas, incorporating both flexible pavements and overlays. Besides being used to calibrate and valid...

  18. Performance and process in collective and individual memory: the role of social decision schemes and memory bias in collective memory.

    Science.gov (United States)

    Van Swol, Lyn M

    2008-04-01

    To assess performance and processes in collective and individual memory, participants watched two job candidates on video. Beforehand, half the participants were told they would be tested on their memory of the interviews, and the other half were asked to make a decision to hire one of the candidates. Afterwards, participants completed a recognition memory task in either a group or individual condition. Groups had better recognition memory than individuals. Individuals made more false positives than false negatives and groups exaggerated this. Post-hoc analysis found that groups only exaggerated the tendency towards false positives on items that reflected negatively on the job candidate. There was no significant difference between instruction conditions. When reaching consensus on the recognition task, groups tended to choose the correct answer if at least two members had the correct answer. This method of consensus is discussed as a factor in groups' superior memory performance.

  19. Standard specification for agencies performing nondestructive testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This specification covers minimum requirements for agencies performing nondestructive testing (NDT). 1.2 When using this specification to assess the capability of, or to accredit NDT agencies, Guide E 1359 shall be used as a basis for the survey. It can be supplemented as necessary with more detail in order to meet the auditor's specific needs. 1.3 This specification can be used as a basis to evaluate testing or inspection agencies, or both, and is intended for use for the qualifying or accrediting, or both, of testing or inspection agencies, public or private. 1.4 The use of SI or inch-pound units, or combination thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to...

  20. Trust that binds: the impact of collective felt trust on organizational performance.

    Science.gov (United States)

    Salamon, Sabrina Deutsch; Robinson, Sandra L

    2008-05-01

    The impact of employees' collective perceptions of being trusted by management was examined with a longitudinal study involving 88 retail stores. Drawing on the appropriateness framework (March, 1994; Weber, Kopelman, & Messick, 2004), the authors develop and test a model showing that when employees in an organization perceive they are trusted by management, increases in the presence of responsibility norms, as well as in the sales performance and customer service performance of the organization, are observed. Moreover, the relationship between perceptions of being trusted and sales performance is fully mediated by responsibility norms. PsycINFO Database Record (c) 2008 APA, all rights reserved.

  1. CFC and HFC recycling equipments: Test performances

    International Nuclear Information System (INIS)

    Picini, P.; Caropreso, G.; Cicoli, G.; Posarelli, M.

    1996-12-01

    Actual regulatory conditions about ozone layer depleting chemicals set problems on their disposal and on the management of plants still using illegal CFCs. Anyway fluids that will replace CFCs (i.e. HFCs) will not be allowed to be spread into the atmosphere, due to their high costs and to the greenhouse effect. A viable solution would be the recovery, purification and recycle of contaminated fluids. ENEA (National Agency for New Technology, Energy and the Environment), in cooperation with ICF (Industria Componenti Frigoriferi) Company leader in the field of air refrigerating and conditioning, patented a device able to extract, to clean and to recycle CFC 12 and HFC 134a in the refrigerating systems. This paper presents experimental data from the qualification tests on a device performing the above mentioned operations regarding systems that use HFC 134a as process fluid

  2. Experimental test of liquid droplet radiator performance

    International Nuclear Information System (INIS)

    Mattick, A.T.; Simon, M.A.

    1986-01-01

    This liquid droplet radiator (LDR) is evolving rapidly as a lightweight system for heat rejection in space power systems. By using recirculating free streams of submillimeter droplets to radiate waste energy directly to space, the LDR can potentially be an order of magnitude lighter than conventional radiator systems which radiate from solid surfaces. The LDR is also less vulnerable to micrometeoroid damage than are conventional radiators, and it has a low transport volume. Three major development issues of this new heat rejection system are the ability to direct the droplet streams with sufficient precision to avoid fluid loss, radiative performance of the array of droplet streams which comprise the radiating elements of the LDR, and the efficacy of the droplet stream collector, again with respect to fluid loss. This paper reports experimental results bearing on the first two issues - droplet aiming in a multikilowatt-sized system, and radiated power from a large droplet array. Parallel efforts on droplet collection and LDR system design are being pursued by several research groups

  3. Reducing power consumption while performing collective operations on a plurality of compute nodes

    Science.gov (United States)

    Archer, Charles J [Rochester, MN; Blocksome, Michael A [Rochester, MN; Peters, Amanda E [Rochester, MN; Ratterman, Joseph D [Rochester, MN; Smith, Brian E [Rochester, MN

    2011-10-18

    Methods, apparatus, and products are disclosed for reducing power consumption while performing collective operations on a plurality of compute nodes that include: receiving, by each compute node, instructions to perform a type of collective operation; selecting, by each compute node from a plurality of collective operations for the collective operation type, a particular collective operation in dependence upon power consumption characteristics for each of the plurality of collective operations; and executing, by each compute node, the selected collective operation.

  4. Honeywell Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Sargusingh, Miriam

    2014-01-01

    The ability to recover and purify water through physiochemical processes is crucial for realizing long-term human space missions, including both planetary habitation and space travel. Because of their robust nature, distillation systems have been actively pursued as one of the technologies for water recovery. The Cascade Distillation System (CDS) is a vacuum rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. The CDS was previously under development through Honeywell and NASA. In 2009, an assessment was performed to collect data to support down-selection and development of a primary distillation technology for application in a lunar outpost water recovery system. Based on the results of this testing, an expert panel concluded that the CDS showed adequate development maturity, TRL-4, together with the best product water quality and competitive weight and power estimates to warrant further development. The Advanced Exploration Systems (AES) Water Recovery Project (WRP) worked to address weaknesses identified by The Panel; namely bearing design and heat pump power efficiency. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades. The CDS will also have been challenged with ISS analog waste streams and a subset of those being considered for Exploration architectures. This paper details interim results of the AES WRP CDS performance testing.

  5. A numerical test of the collective coordinate method

    International Nuclear Information System (INIS)

    Dobrowolski, T.; Tatrocki, P.

    2008-01-01

    The purpose of this Letter is to compare the dynamics of the kink interacting with the imperfection which follows from the collective coordinate method with the numerical results obtained on the ground of the field theoretical model. We showed that for weekly interacting kinks the collective coordinate method works similarly well for low and extremely large speeds

  6. WhalePower tubercle blade power performance test report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-15

    Toronto-based WhalePower Corporation has developed turbine blades that are modeled after humpback whale flippers. The blades, which incorporate tubercles along the leading edge of the blade, have been fitted to a Wenvor 25 kW turbine installed in North Cape, Prince Edward Island at a test site for the Wind Energy Institute of Canada (WEICan). A test was conducted to characterize the power performance of the prototype wind turbine. This report described the wind turbine configuration with particular reference to turbine information, power rating, blade information, tower information, control systems and grid connections. The test site was also described along with test equipment and measurement procedures. Information regarding power output as a function of wind speed was included along with power curves, power coefficient and annual energy production. The results for the power curve and annual energy production contain a level of uncertainty. While measurements for this test were collected and analyzed in accordance with International Electrotechnical Commission (IEC) standards for performance measurements of electricity producing wind turbines (IEC 61400-12-1), the comparative performance data between the prototype WhalePower wind turbine blade and the Wenvor standard blade was not gathered to IEC data standards. Deviations from IEC-61400-12-1 procedures were listed. 6 tabs., 16 figs., 3 appendices.

  7. Performance improvement planning : developing effective billing and collection practices

    OpenAIRE

    anonymous

    2008-01-01

    Effective billing and collection systems are a critical component for ensuring the viability of a service provider. Improving billing and collection activities has an immediate impact on the revenue streams of a service provider that can, in turn, help the service provider in improving services. However, while effective billing and collection practices depend on many internal factors (including customer databases, the extent of metered and unmetered service provision, tariff and billing struc...

  8. Performance Tests of a Mechanical Pump in Sodium Environment

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Kim, Byeongyeon; Cho, Youngil; Jung, Min-Hwan; Gam, Da-Young; Lee, Yong Bum; Jeong, Ji-Young; Kim, Jong-Bum [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Water is often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Nevertheless, to ensure the performance, safety, and operability of major components before its installation in the SFR, a series of demonstration experiments of some components in sodium environment should be positively necessary. So, SFR NSSS System Design Division of Korea Atomic Energy Research Institute (KAERI) built various sodium experimental facilities, especially STELLA-1 in 2012. STELLA-1 (Sodium inTegral Effect test Loop for safety simuLation and Assessment) is a large-scale separated effect test facility for demonstrating the thermal-hydraulic performances of major components such as a Sodium-to-Sodium heat exchanger (DHX), Sodium-to-Air heat exchanger (AHX) of the decay heat removal system, and mechanical sodium pump of the primary heat transport system (PHTS). The mechanical pump in-sodium performance test was successfully performed with good reproducibility of the experiment and data to compare hydraulic characteristic of a mechanical pump in-water was collected. In effect of temperature variation on the pump pressure head, reduction of pump pressure head at 250℃ by 0.57% of that of 300℃ maybe the result of an increase in sodium viscosity by 13.6% according to operating temperature decrease by 50℃. Also, we confirmed that the more flywheel weight, the longer halving time and the more initial flow rate when the pump seized, the shorter halving time. The results of the mechanical pump performance test data in sodium environment will be used to compare with that of the in water environment after the evaluation of measurement uncertainty for tests.

  9. A comparison of human papillomavirus testing of clinician-collected and self-collected samples during follow-up after screen-and-treat.

    Science.gov (United States)

    Taylor, Sylvia; Wang, Chunhui; Wright, Thomas C; Denny, Lynette; Kuhn, Louise

    2011-08-15

    Screen-and-treat cervical cancer prevention programs based on high-risk human papillomavirus (HPV) testing and cryotherapy have been shown to be effective in resource-limited settings. However, because cryotherapy is not 100% effective, follow-up is needed after treatment to detect post-treatment failures. We compared the test performances of high-risk HPV testing (Hybrid Capture 2) using self-collected and clinician-collected samples as well as cervical cytology for identifying cervical intraepithelial neoplasia grades 2 or 3 or invasive cervical cancer (CIN2+) among women who did (n=812) and did not (n=1858) undergo cryotherapy in a South African screen-and-treat trial. At 6 months after enrolment (and after cryotherapy, if performed), women were tested using all three screening methods and then underwent colposcopy/biopsy. A predefined subset of women (n=1,455) had extended follow-up with colposcopy/biopsy at 12 months. A total of 33 and 91 cases of CIN2+ were detected among treated and untreated women, respectively. The sensitivity of HPV testing using clinician-collected samples and cervical cytology did not differ by treatment status. HPV testing of clinician-collected samples detected the most cases of CIN2+ among both treated (85%) and untreated (91%) women (p=0.31). Cytology (at a cutoff of atypical squamous cells of undetermined significance or greater) detected 76% of cases among both treated and untreated women. However, the sensitivity of HPV testing using self-collected samples was significantly lower among treated versus untreated women (55% vs. 78%, p=0.01). HPV testing using self-collected vaginal specimens may be useful in primary screening but performs poorly for detecting post-treatment failures. Copyright © 2010 UICC.

  10. Boxing headguard performance in punch machine tests.

    Science.gov (United States)

    McIntosh, Andrew S; Patton, Declan A

    2015-09-01

    The paper presents a novel laboratory method for assessing boxing headguard impact performance. The method is applied to examine the effects of headguards on head impact dynamics and injury risk. A linear impactor was developed, and a range of impacts was delivered to an instrumented Hybrid III head and neck system both with and without an AIBA (Association Internationale de Boxe Amateur)-approved headguard. Impacts at selected speeds between 4.1 and 8.3 m/s were undertaken. The impactor mass was approximately 4 kg and an interface comprising a semirigid 'fist' with a glove was used. The peak contact forces were in the range 1.9-5.9 kN. Differences in head impact responses between the Top Ten AIBA-approved headguard and bare headform in the lateral and forehead tests were large and/or significant. In the 8.3 m/s fist-glove impacts, the mean peak resultant headform accelerations for bare headform tests was approximately 130 g compared with approximately 85 g in the forehead impacts. In the 6.85 m/s bare headform impacts, mean peak resultant angular head accelerations were in the range of 5200-5600 rad/s(2) and almost halved by the headguard. Linear and angular accelerations in 45° forehead and 60° jaw impacts were reduced by the headguard. The data support the opinion that current AIBA headguards can play an important role in reducing the risk of concussion and superficial injury in boxing competition and training. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. ACER Chemistry Test Item Collection. ACER Chemtic Year 12.

    Science.gov (United States)

    Australian Council for Educational Research, Hawthorn.

    The chemistry test item banks contains 225 multiple-choice questions suitable for diagnostic and achievement testing; a three-page teacher's guide; answer key with item facilities; an answer sheet; and a 45-item sample achievement test. Although written for the new grade 12 chemistry course in Victoria, Australia, the items are widely applicable.…

  12. Differences in gender performance on competitive physics selection tests

    Science.gov (United States)

    Wilson, Kate; Low, David; Verdon, Matthew; Verdon, Alix

    2016-12-01

    [This paper is part of the Focused Collection on Gender in Physics.] We have investigated gender differences in performance over the past eight years on the Australian Science Olympiad Exam (ASOE) for physics, which is taken by nearly 1000 high school students each year. The ASOE, run by Australian Science Innovations (ASI), is the initial stage of the process of selection of teams to represent Australia at the Asian and International Physics Olympiads. Students taking the exam are generally in their penultimate year of school and selected by teachers as being high performing in physics. Together with the overall differences in facility, we have investigated how the content and presentation of multiple-choice questions (MCQs) affects the particular answers selected by male and female students. Differences in the patterns of responses by male and female students indicate that males and females might be modeling situations in different ways. Some strong patterns were found in the gender gaps when the questions were categorized in five broad dimensions: content, process required, difficulty, presentation, and context. Almost all questions saw male students performing better, although gender differences were relatively small for questions with a more abstract context. Male students performed significantly better on most questions with a concrete context, although notable exceptions were found, including two such questions where female students performed better. Other categories that showed consistently large gaps favoring male students include questions with projectile motion and other two-dimensional motion or forces content, and processes involving interpreting diagrams. Our results have important implications, suggesting that we should be able to reduce the gender gaps in performance on MCQ tests by changing the way information is presented and setting questions in contexts that are less likely to favor males over females. This is important as MCQ tests are

  13. Differences in gender performance on competitive physics selection tests

    Directory of Open Access Journals (Sweden)

    Kate Wilson

    2016-08-01

    Full Text Available [This paper is part of the Focused Collection on Gender in Physics.] We have investigated gender differences in performance over the past eight years on the Australian Science Olympiad Exam (ASOE for physics, which is taken by nearly 1000 high school students each year. The ASOE, run by Australian Science Innovations (ASI, is the initial stage of the process of selection of teams to represent Australia at the Asian and International Physics Olympiads. Students taking the exam are generally in their penultimate year of school and selected by teachers as being high performing in physics. Together with the overall differences in facility, we have investigated how the content and presentation of multiple-choice questions (MCQs affects the particular answers selected by male and female students. Differences in the patterns of responses by male and female students indicate that males and females might be modeling situations in different ways. Some strong patterns were found in the gender gaps when the questions were categorized in five broad dimensions: content, process required, difficulty, presentation, and context. Almost all questions saw male students performing better, although gender differences were relatively small for questions with a more abstract context. Male students performed significantly better on most questions with a concrete context, although notable exceptions were found, including two such questions where female students performed better. Other categories that showed consistently large gaps favoring male students include questions with projectile motion and other two-dimensional motion or forces content, and processes involving interpreting diagrams. Our results have important implications, suggesting that we should be able to reduce the gender gaps in performance on MCQ tests by changing the way information is presented and setting questions in contexts that are less likely to favor males over females. This is important as MCQ

  14. 34 CFR 300.601 - State performance plans and data collection.

    Science.gov (United States)

    2010-07-01

    ... Monitoring, Technical Assistance, and Enforcement § 300.601 State performance plans and data collection. (a... 34 Education 2 2010-07-01 2010-07-01 false State performance plans and data collection. 300.601... described in § 300.600(d). (b) Data collection. (1) Each State must collect valid and reliable information...

  15. Science Library of Test Items. Volume Twenty-Two. A Collection of Multiple Choice Test Items Relating Mainly to Skills.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  16. Science Library of Test Items. Volume Eighteen. A Collection of Multiple Choice Test Items Relating Mainly to Chemistry.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  17. Science Library of Test Items. Volume Twenty. A Collection of Multiple Choice Test Items Relating Mainly to Physics, 1.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  18. Science Library of Test Items. Volume Seventeen. A Collection of Multiple Choice Test Items Relating Mainly to Biology.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  19. Science Library of Test Items. Volume Nineteen. A Collection of Multiple Choice Test Items Relating Mainly to Geology.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  20. Harmonic pulse testing for well performance monitoring

    NARCIS (Netherlands)

    Fokker, Peter A.; Salina Borello, Eloisa; Verga, Francesca; Viberti, Dario

    2018-01-01

    Harmonic testing was developed as a form of well testing that can be applied during ongoing production or injection operations, as a pulsed signal is superimposed on the background pressure trend. Thus no interruption of well and reservoir production is needed before and during the test. If the

  1. Spent fuel metal storage cask performance testing and future spent fuel concrete module performance testing

    International Nuclear Information System (INIS)

    McKinnon, M.A.; Creer, J.M.

    1988-10-01

    REA-2023 Gesellshaft fur Nuklear Service (GNS) CASTOR-V/21, Transnuclear TN-24P, and Westinghouse MC-10 metal storage casks, have been performance tested under the guidance of the Pacific Northwest Laboratory to determine their thermal and shielding performance. The REA-2023 cask was tested under Department of Energy (DOE) sponsorship at General Electric's facilities in Morris, Illinois, using BWR spent fuel from the Cooper Reactor. The other three casks were tested under a cooperative agreement between Virginia Power Company and DOE at the Idaho National Engineering Laboratory (INEL) by EGandG Idaho, Inc., using intact spent PWR fuel from the Surry reactors. The Electric Power Research Institute (EPRI) made contributions to both programs. A summary of the various cask designs and the results of the performance tests is presented. The cask designs include: solid and liquid neutron shields; lead, steel, and nodular cast iron gamma shields; stainless steel, aluminum, and copper baskets; and borated materials for criticality control. 4 refs., 8 figs., 6 tabs

  2. Performance of a 2-megawatt high voltage test load

    International Nuclear Information System (INIS)

    Horan, D.; Kustom, R.; Ferguson, M.

    1995-01-01

    A high-power, water-cooled resistive load which simulates the electrical load characteristics of a high-power klystron, capable of 2 megawatts dissipation at 95 kV DC, was built and installed at the Advanced Photon Source for use in load-testing high voltage power supplies. During this testing, the test load has logged approximately 35 hours of operation at power levels in excess of one mezawatt. Slight variations in the resistance of the load during operation indicate that leakage currents in the cooling water may be a significant factor affecting the performance of the load. Sufficient performance data have been collected to indicate that leakage current through the deionized (DI) water coolant shunts roughly 15 percent of the full-load current around the load resistor elements. The leakage current could cause deterioration of internal components of the load. The load pressure vessel was disassembled and inspected internally for any signs of significant wear and distress. Results of this inspection and possible modifications for improved performance will be discussed

  3. Ex-Post : The Investment Performance of Collectible Stamps

    NARCIS (Netherlands)

    Dimson, E.; Spaenjers, C.

    2009-01-01

    This paper investigates the returns on British collectible postage stamps over the very long run, based on stamp catalogue prices. Between 1900 and 2008, we find an annualized return on stamps of 6.7% in nominal terms, which is equivalent to an average real return of 2.7% per annum. Prices have

  4. Travel Time Data Collection Field Tests - Lessons Learned

    Science.gov (United States)

    1999-06-28

    The Los Angeles Spread Spectrum Radio (SSR) Traffic Signal Interconnect Field Operational Test (FOT) investigated the feasibility of using wireless communications as an alternative to traditional hard-wire interconnection, to extend the coverage of c...

  5. 40 CFR 63.5160 - What performance tests must I complete?

    Science.gov (United States)

    2010-07-01

    ...) Method 25 or 25A of 40 CFR part 60, appendix A, is used to determine total gaseous non-methane organic... before any substantial heat exchange occurs. (B) Use the data collected during the performance test to...

  6. Software development for simplified performance tests and weekly performance check in Younggwang NPP Unit 3 and 4

    International Nuclear Information System (INIS)

    Hur, K. Y.; Jang, S. H.; Lee, J. W.; Kim, J. T.; Park, J. C.

    2002-01-01

    This paper covers the current status of turbine cycle performance test in nuclear power plants and the software development which can solve some shortcomings related to performance tests. The software developed is for simplified performance tests and weekly performance checks in Yonggwang nuclear power plant unit 3 and 4. This software includes the requirements from the efficiency division for the consistency with actual performance analysis work and the usability of the collected performance test data. From the working survey, we identify the difference between the embedded performance analysis modules and the actual performance analysis work. This software helps operation or maintenance personnel to reduce work load, to support the trend analysis of essential parameters in a turbine cycle, and to utilize the correction curves for the decision-making in their work

  7. Performance and safety of femoral central venous catheters in pediatric autologous peripheral blood stem cell collection.

    Science.gov (United States)

    Cooling, Laura; Hoffmann, Sandra; Webb, Dawn; Yamada, Chisa; Davenport, Robertson; Choi, Sung Won

    2017-12-01

    Autologous peripheral blood hematopoietic progenitor cell collection (A-HPCC) in children typically requires placement of a central venous catheter (CVC) for venous access. There is scant published data regarding the performance and safety of femoral CVCs in pediatric A-HPCC. Seven-year, retrospective study of A-HPCC in pediatric patients collected between 2009 and January 2017. Inclusion criteria were an age ≤ 21 years and A-HPCC using a femoral CVC for venous access. Femoral CVC performance was examined by CD34 collection rate, inlet rate, collection efficiency (MNC-FE, CD34-FE), bleeding, flow-related adverse events (AE), CVC removal, and product sterility testing. Statistical analysis and graphing were performed with commercial software. A total of 75/119 (63%) pediatric patients (median age 3 years) met study criteria. Only 16% of children required a CVC for ≥ 3 days. The CD34 collect rate and CD34-FE was stable over time whereas MNC-FE decreased after day 4 in 80% of patients. CD34-FE and MNC-FE showed inter- and intra-patient variability over time and appeared sensitive to plerixafor administration. Femoral CVC showed fewer flow-related AE compared to thoracic CVC, especially in pediatric patients (6.7% vs. 37%, P = 0.0005; OR = 0.12 (95%CI: 0.03-0.45). CVC removal was uneventful in 73/75 (97%) patients with hemostasis achieved after 20-30 min of pressure. In a 10-year period, there were no instances of product contamination associated with femoral CVC colonization. Femoral CVC are safe and effective for A-HPCC in young pediatric patients. Femoral CVC performance was maintained over several days with few flow-related alarms when compared to thoracic CVCs. © 2017 Wiley Periodicals, Inc.

  8. Design and Testing of High Performance Brushes.

    Science.gov (United States)

    1983-05-01

    shows an example. What ordinarily serves as a ’brush’. applitations such as homopolar motors / generators and in transmitting current across an interface...speed current collection bricating layer of silver and graphite debris. systems for homopolar electrical machines. Use The other, associated with the...performantc hornopolar by examining the origin of the power losses when electrical motors and generators, based either on superconducting or brushes

  9. Proof of Performance Test Report MANTIS

    National Research Council Canada - National Science Library

    2005-01-01

    ... (NVESD), Humanitarian Demining Branch (HD), the assessment was conducted by HD staff members and supported by engineers from the United Kingdom under the auspices of the International Evaluation Test Program for Humanitarian Demining (ITEP...

  10. The relationship between standardised test performance and ...

    African Journals Online (AJOL)

    The English language proficiency of South African learners is integral to ... in standardised reading/writing tests in English Second Language (ESL) and (2) the use of ... and their relationship with the ESL learner's language learning strategies.

  11. Accelerated Performance Testing on the 2006 NCAT Pavement Test Track

    Science.gov (United States)

    2009-12-01

    The original National Center for Asphalt Technology (NCAT) Pavement Test Track was built in 2000 in Opelika, Alabama where it has served as a state-of-the-art, full-scale, closed-loop accelerated loading facility. The construction, operation, and res...

  12. Nuclear material control and accountancy planning and performance testing

    International Nuclear Information System (INIS)

    Mike Enhinger; Dennis Wilkey; Rod Martin; Ken Byers; Brian Smith

    1999-01-01

    An overview of performance testing as used at U.S. Department of Energy facilities is provided. Performance tests are performed on specific aspects of the regulations or site policy. The key issues in establishing a performance testing program are: identifying what needs to be tested; determining how to test; establishing criteria to evaluate test results. The program elements of performance testing program consist of: planning; coordination; conduct; evaluation. A performance test may be conducted of personnel or equipment. The DOE orders for nuclear material control and accountancy are divided into three functional areas: program administration, material accounting, and material control. Examples performance tests may be conducted on program administration, accounting, measurement and measurement control, inventory, and containment [ru

  13. Development of a grinding-specific performance test set-up.

    Science.gov (United States)

    Olesen, C G; Larsen, B H; Andresen, E L; de Zee, M

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding performance.

  14. Performance analysis in Japanese field test program; Field test data kara no chiiki hatsuden kaiseki hoho

    Energy Technology Data Exchange (ETDEWEB)

    Sugiyama, H.; Kurokawa, K.; Uchida, D. [Tokyo University of Agriculture and Technology, Tokyo (Japan); Otani, K.; Sakuta, K.; Tsuda, I. [Electrotechnical Laboratory, Tsukuba (Japan); Oshiro, T.; Sakamoto, K. [Japan Quality Assurance Organization, Tokyo (Japan)

    1997-11-25

    Power generation characteristics are investigated using data collected in photovoltaic power generation field tests being undertaken by NEDO (New Energy and Industrial Technology Development Organization). The photovoltaic power generation system performance is evaluated by examining loss factors leading to degradation in system performance, with weather conditions such as variation in insolation and air temperature, inverter performance, and shadows cast by surrounding buildings taken into consideration. As the result, it is found that the important loss factors are degradation in module performance due to elevated temperature, drift in the maximum output control, degraded inverter performance due to input power variation, effect of shadows, etc. It is learned that system is greatly affected by degradation in module performance due to increased temperature in summer and by shadows in winter, the two being responsible for the output coefficient dropping to approximately 75% throughout the year. The output coefficient frequency distribution charts for the 75 test sites confirm that the rate is as low as 70-80% at many sites. As for the system operating time, it tends to be longer in West Japan where the annual insolation rate is higher. 3 refs., 10 figs.

  15. The effects of gamelike features and test location on cognitive test performance and participant enjoyment

    Directory of Open Access Journals (Sweden)

    Jim Lumsden

    2016-07-01

    Full Text Available Computerised cognitive assessments are a vital tool in the behavioural sciences, but participants often view them as effortful and unengaging. One potential solution is to add gamelike elements to these tasks in order to make them more intrinsically enjoyable, and some researchers have posited that a more engaging task might produce higher quality data. This assumption, however, remains largely untested. We investigated the effects of gamelike features and test location on the data and enjoyment ratings from a simple cognitive task. We tested three gamified variants of the Go-No-Go task, delivered both in the laboratory and online. In the first version of the task participants were rewarded with points for performing optimally. The second version of the task was framed as a cowboy shootout. The third version was a standard Go-No-Go task, used as a control condition. We compared reaction time, accuracy and subjective measures of enjoyment and engagement between task variants and study location. We found points to be a highly suitable game mechanic for gamified cognitive testing because they did not disrupt the validity of the data collected but increased participant enjoyment. However, we found no evidence that gamelike features could increase engagement to the point where participant performance improved. We also found that while participants enjoyed the cowboy themed task, the difficulty of categorising the gamelike stimuli adversely affected participant performance, increasing No-Go error rates by 28% compared to the non-game control. Responses collected online vs. in the laboratory had slightly longer reaction times but were otherwise very similar, supporting other findings that online crowdsourcing is an acceptable method of data collection for this type of research.

  16. Phase 1: ISOCELL demonstration test performance review

    International Nuclear Information System (INIS)

    Chatwin, T.D.

    1991-04-01

    This document consolidates and organizes information available concerning cryogenic retrieval of hazardous, radioactive, and mixed wastes and is mainly derived from a report on the ISOCELL Demonstration Project prepared by Concept RKK, Ltd. ISOCELL cryogenic technology is designed to immobilize hazardous, radioactive, and mixed waste by creating a block of frozen waste and soil that can be safely retrieved, stored, transported, and treated with a minimum of dust. A test of the ISOCELL process was conducted in Carnation, Washington by Concept RKK, Ltd. Test conditions were compared to possible testing conditions at Idaho National Engineering Laboratory. Results indicate ISOCELL technology successfully froze wet soil into a soil block capable of being lifted. 5 refs., 6 figs., 1 tab

  17. Comparison of performance test for protective aprons

    International Nuclear Information System (INIS)

    Fukutomi, Yukimi; Yoshimoto, Masahiro; Kawakami, Toshiaki

    1989-01-01

    Each one radioprotective apron (lead equivalent, 0.35 mmPb) was commercially available in November 1988 from 7 domestic and 3 foreign companies. According to the JIS standards 4803, these aprons were evaluated for the following items: 1) display of aprons, including packing and the structure; 2) non-breaking test, including appearance, size, lead equivalent, and uniformity; 3) breaking test, including lead equivalent, uniformity, stregth, and structure; 4) feeling of wearing an apron. An overall evaluation revealed that only two aprons were in accordance with the JIS standard. Careful wearing of the protective apron is stressed. (N.K.)

  18. 10 CFR 26.168 - Blind performance testing.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Blind performance testing. 26.168 Section 26.168 Energy... and Human Services § 26.168 Blind performance testing. (a) Each licensee and other entity shall submit blind performance test samples to the HHS-certified laboratory. (1) During the initial 90-day period of...

  19. 77 FR 10509 - Agency Information Collection Activities; Proposed Collection; Comment Request; Drug Testing for...

    Science.gov (United States)

    2012-02-22

    ... that may potentially affect communities and the surrounding environment. Releases may be accidental... may be responsible for testing their employees for the use of marijuana, cocaine, opiates.... Respondents/Affected Entities: EPA contractor employees who work at sensitive sites. Estimated Number of...

  20. GPS Device Testing Based on User Performance Metrics

    Science.gov (United States)

    2015-10-02

    1. Rationale for a Test Program Based on User Performance Metrics ; 2. Roberson and Associates Test Program ; 3. Status of, and Revisions to, the Roberson and Associates Test Program ; 4. Comparison of Roberson and DOT/Volpe Programs

  1. Innovation and performance : A collection of microdata studies

    NARCIS (Netherlands)

    Van Leeuwen, G.

    2009-01-01

    There are still many puzzles to be solved concerning the relation between innovation and firm performance, in particular concerning the distinct roles of information and communication technology (ICT) and Research and Development (R&D) in creating new or improved products or production processes.

  2. Collective efficacy, cohesion and performance in spanish amateur female basketball

    Directory of Open Access Journals (Sweden)

    Raul Mart\\u00EDnez-Santos

    2013-01-01

    Full Text Available El objetivo de este estudio fue el de examinar las relaciones entre la eficacia colectiva, la cohesión y el rendimiento en el baloncesto español amateur femenino. Para ello, 68 jugadoras amateurs de ocho equipos diferentes completaron las versiones españolas del Collective Efficacy Questionnaire for Sport y del Group Environment Questionnaire for Sports al final de la temporada 2011/2012. Los resultados mostraron que la eficacia colectiva declarada por las jugadoras es un potente factor de explicación de rendimiento, a diferencia de la cohesión de grupo general. Sin embargo, y en consonancia con la primera conclusión, las jugadoras de los equipos exitosos declararon mayores niveles de atracción e integración con el grupo en relación a la tarea.

  3. Factors affecting the auction price of Veldram performance tested ...

    African Journals Online (AJOL)

    The popularity of these auctions for performance tested rams (89.4 % of rams sold) indicate that Veld tested rams were sought after by buyers. The sale price of 296 Veld tested Dorper rams sold between 1994 and 2001, covering seven different tests, were compared with their measured and observed performances.

  4. SIMS prototype system 4 - performance test report

    Science.gov (United States)

    1978-01-01

    A self-contained, preassembled air type solar system, designed for installation remote from the dwelling, to provide space heating and hot water was evaluated. Data analysis is included which documents the system performance and verifies its suitability for field installation.

  5. Wastewater Collection Performance on Communal Sanitation System in Cimahi Indonesia

    Directory of Open Access Journals (Sweden)

    Mohamad Rangga Sururi

    2017-01-01

    Full Text Available In dense population cities, the effectiveness of the communal system in handling municipal domestic wastewater is important. This research aimed to evaluate the effectiveness of pipe dimensioning process and determine it as a wastewater collector to be served as a reactor through a tracer test. Thus, this work may give some inputs for a reliable design criteria for communal system in Indonesia. The reaserch area was at communal system on Tegal Kawung RT 05 RW 08. It served 37 household which was identified using built drawings and field checking. The number of communal septic tank user was 150 people who approximately use water of 134.33 L/person/day and more than 75% (107.46 L/persons/day was discharged to the system. The tracer test was done between the control box with the distance of 27.94 m and diameter of 150 mm. Based on the mathematical model that was used, the diameter of the pipe should be 100 mm. The tracer test showed that the piping system is the Plug Flow Reactor but it is not yet effective, shown by the MDI value of 3.36.

  6. Live Operation Data Collection Optimization and Communication for the Domestic Nuclear Detection Office's Rail Test Center

    International Nuclear Information System (INIS)

    Gelston, Gariann M.

    2010-01-01

    For the Domestic Nuclear Detection Office's Rail Test Center (i.e., DNDO's RTC), port operation knowledge with flexible collection tools and technique are essential in both technology testing design and implementation intended for live operational settings. Increased contextual data, flexibility in procedures, and rapid availability of information are keys to addressing the challenges of optimization, validation, and analysis within live operational setting data collection. These concepts need to be integrated into technology testing designs, data collection, validation, and analysis processes. A modified data collection technique with a two phased live operation test method is proposed.

  7. An evaluation of 1D loss model collections for the off-design performance prediction of automotive turbocharger compressors

    International Nuclear Information System (INIS)

    Harley, P; Spence, S; Early, J; Filsinger, D; Dietrich, M

    2013-01-01

    Single-zone modelling is used to assess different collections of impeller 1D loss models. Three collections of loss models have been identified in literature, and the background to each of these collections is discussed. Each collection is evaluated using three modern automotive turbocharger style centrifugal compressors; comparisons of performance for each of the collections are made. An empirical data set taken from standard hot gas stand tests for each turbocharger is used as a baseline for comparison. Compressor range is predicted in this study; impeller diffusion ratio is shown to be a useful method of predicting compressor surge in 1D, and choke is predicted using basic compressible flow theory. The compressor designer can use this as a guide to identify the most compatible collection of losses for turbocharger compressor design applications. The analysis indicates the most appropriate collection for the design of automotive turbocharger centrifugal compressors

  8. Drop performance test and evaluation for HANARO shutoff units

    International Nuclear Information System (INIS)

    Jung, Y. H.; Cho, Y. K.; Lee, J. H.; Choi, Y. S.; Woo, J. S.

    2004-01-01

    The function of the shutoff units of the HANARO is to rapidly insert the shutoff rod into the reactor core for safe shutdown of reactor. This paper describes drop performance test and evaluation for a shutoff unit for the technical verification of lifetime extension and localization of the HANARO shutoff units. We have performed preliminary drop performance tests for a shutoff unit at 1/2-core test loop and analyzed through the comparison with the test results performed during design verification test and the results of the periodic performance test in HANARO. It shows that the results of the local fabrication, installation and alignment for the shutoff unit meet the basic performance requirements, Furthermore, the performance evaluation method of the periodic drop test of the HANARO shutoff units is a conservative method comparing with the real drop time

  9. Development of a grinding-specific performance test set-up

    DEFF Research Database (Denmark)

    Olesen, C. G.; Larsen, B. H.; Andresen, E. L.

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding...... demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding...... and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding...

  10. Performance-based containment leakage testing

    International Nuclear Information System (INIS)

    Cybulskis, P.

    1995-01-01

    The U.S. Nuclear Regulatory Commission (NRC) is reviewing regulatory requirements in an effort to revise those that are marginal to safety but impose significant burdens on licensees. Identification of requirements marginal to safety and development and evaluation of alternatives utilize the NRC safety goals and insights from probabilistic risk assessments (PRAs). Since earlier studies found design-basis containment leakage to be a minor contributor to reactor accident risk, containment leakage testing has been selected as a candidate for change in regulations. This paper summarizes the technical analyses supporting the NRC proposal to amend Appendix J of 10 CFR Part 50 as its first effort to decrease unnecessary regulatory burdens on licensees

  11. Experimental test of liquid droplet radiator performance

    Science.gov (United States)

    Mattick, A. T.; Simon, M. A.

    The liquid droplet radiator (LDR) is a heat rejection system for space power systems wherein an array of heated liquid droplets radiates energy directly to space. The use of submillimeter droplets provides large radiating area-to-mass ratio, resulting in radiator systems which are several times lighter than conventional solid surface radiators. An experiment is described in which the power radiated by an array of 2300 streams of silicone oil droplets is measured to test a previously developed theory of the LDR radiation process. This system would be capable of rejecting several kW of heat in space. Furthermore, it would be suitable as a modular unit of an LDR designed for 100-kW power levels. The experiment provided confirmation of the theoretical dependence of droplet array emissivity on optical depth. It also demonstrated the ability to create an array of more than 1000 droplet streams having a divergence less than 1 degree.

  12. Stirling convertor performance mapping test results

    Science.gov (United States)

    Qiu, Songgang; Peterson, Allen A.; White, Maurice A.; Faultersack, Franklyn; Redinger, Darin L.; Petersen, Stephen L.

    2002-01-01

    The Department of Energy (DOE) has selected Free-Piston Stirling Convertors as a technology for future advanced radioisotope space power systems. In August 2000, DOE awarded competitive Phase I, Stirling Radioisotope Generator (SRG) power system integration contracts to three major aerospace contractors, resulting in SRG conceptual designs in February 2001. All three contractors based their designs on the Technology Demonstration Convertor (TDC) developed by Stirling Technology Company (STC) for DOE. The contract award to a single system integration contractor for Phases II and III of the SRG program is anticipated in late 2001. The first potential SRG mission is targeted for a Mars rover. Recent TDC performance data are provided in this paper, together with predictions from Stirling simulation models. .

  13. Performance of a hydrostatic sampler for collecting samples at the water-sediment interface in lakes

    Directory of Open Access Journals (Sweden)

    Fernando PEDROZO

    2008-02-01

    Full Text Available The water-sediment interface plays a significant role in the determination of the trophic degree of a waterbody. Numerous redox reactions take place there, resulting in the release of contaminants from the sediments to the water column. The aim of the present work was to develop an equipment for collecting samples from the water-sediment interface. Such equipment was to have a simple design, low construction cost, no depth limitations, and high levels of personal safety and to be reliable in the collection of samples. The performance of the hydrostatic sampler thus developed was tested against samples collected either remotely with a corer or directly with syringes by autonomous divers. The hydrostatic sampler permits access to depths where the costs of the traditional diving methodology are expensive, and where working conditions are dangerous for the diver. The hydrostatic sampler provides an additional means of collecting samples from the water-sediment interface, which together with pore-water samples, facilitates the investigation and understanding of chemical mechanisms in lakes, for instance, those that control the P release from sediment to the water column.

  14. Test Operations Procedure (TOP) 01-1-025 Camouflage Performance Testing Using Observers

    Science.gov (United States)

    2016-05-05

    one observer approaching the test article at a time, but these tests are time consuming and expensive to execute for collection of statistically...best data collection approach is live in the field using only one observer for each trial run but these tests are extremely time consuming and...with viewing angle, relative to the ground plane of the observation should be considered in the test design. The impact of aspect angle, such as

  15. New test methods for BIPV. Results from IP performance

    International Nuclear Information System (INIS)

    Jol, J.C.; Van Kampen, B.J.M.; De Boer, B.J.; Reil, F.; Geyer, D.

    2009-11-01

    Within the Performance project new test procedures for PV building products and the building performance as a whole when PV is applied in buildings have been drafted. It has resulted in a first draft of new test procedures for PV building products and proposals for tests for novel BIPV technology like thin film. The test proposed are a module breakage test for BIPV products, a fire safety test for BIPV products and a dynamic load test for BIPV products. Furthermore first proposals of how flexible PV modules could be tested in an appropriate way to ensure long time quality and safety of these new products are presented.

  16. Leveraging High Performance Computing for Managing Large and Evolving Data Collections

    Directory of Open Access Journals (Sweden)

    Ritu Arora

    2014-10-01

    Full Text Available The process of developing a digital collection in the context of a research project often involves a pipeline pattern during which data growth, data types, and data authenticity need to be assessed iteratively in relation to the different research steps and in the interest of archiving. Throughout a project’s lifecycle curators organize newly generated data while cleaning and integrating legacy data when it exists, and deciding what data will be preserved for the long term. Although these actions should be part of a well-oiled data management workflow, there are practical challenges in doing so if the collection is very large and heterogeneous, or is accessed by several researchers contemporaneously. There is a need for data management solutions that can help curators with efficient and on-demand analyses of their collection so that they remain well-informed about its evolving characteristics. In this paper, we describe our efforts towards developing a workflow to leverage open science High Performance Computing (HPC resources for routinely and efficiently conducting data management tasks on large collections. We demonstrate that HPC resources and techniques can significantly reduce the time for accomplishing critical data management tasks, and enable a dynamic archiving throughout the research process. We use a large archaeological data collection with a long and complex formation history as our test case. We share our experiences in adopting open science HPC resources for large-scale data management, which entails understanding usage of the open source HPC environment and training users. These experiences can be generalized to meet the needs of other data curators working with large collections.

  17. Relationships between cohesion, collective efficacy and performance in professional basketball teams: an examination of mediating effects.

    Science.gov (United States)

    Heuzé, Jean-Philippe; Raimbault, Nicolas; Fontayne, Paul

    2006-01-01

    The main aim of this study was to examine mediating effects in the relationships between cohesion, collective efficacy and performance in professional basketball teams. A secondary aim was to examine the correlates of collective efficacy in a professional sport. A total of 154 French and foreign professional players completed French or English versions of questionnaires about cohesion and collective efficacy. Two composite measures of individual performance were used (pre- and post-performance). Individual-level analyses were performed. Regression analyses supported two mediating relationships with collective efficacy as a mediator of the pre-performance - Group integration-task relationship, and Group integration-task as a mediator of the pre-performance - collective efficacy relationship. Statistical analyses indicated that neither Group integration-task nor collective efficacy was a better mediator in the relationship between pre-performance and the other group variables. Results also revealed positive relationships between three dimensions of cohesion (i.e. Individual attractions to the group-task, Group integration-task, Group integration-social) and collective efficacy. These findings suggest that in professional basketball teams, staff members should look after athletes who perform at a lower or below their usual level because their performances might lead them into a downward cohesion - collective efficacy spiral. Staff members should also develop a high quality of group functioning, both on and off the basketball court, given its relationship with collective efficacy.

  18. Evaluation of home collection performed by a human milk bank in a university hospital in Brazil.

    Directory of Open Access Journals (Sweden)

    Glória Menezes

    2014-05-01

    Full Text Available Objective. Evaluation of procedures during household milking and transport of human milk associated with their quality control. Materials and methods. 48 donors registered in the Human Milk Bank of the Clinics Hospital of the Federal University at Uberlândia. Observations were made during home visits. A checklist was elaborated according to the technical standards for human milk banks, been associated with  physical-chemical, and microbiological controls. The chi-square test, logistic regression and Spearman test (p menor que 0.05 were used for data analysis. Results. The results suggest that most donors assimilated the guidelines of the milk bank staff and procedures were satisfactorily performed. Conclusion. It could be demonstrated that milking and home collection are safe and effective ways for obtaining donated human milk.

  19. Fenestration System Performance Research, Testing, and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jim Benney

    2009-11-30

    The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be

  20. Reliability performance testing of totally encapsulating chemical protective suits

    International Nuclear Information System (INIS)

    Johnson, J.S.; Swearengen, P.M.

    1991-01-01

    The need to assure a high degree of reliability for totally encapsulating chemical protective (TECP) suits has been recognized by Lawrence Livermore National Laboratory's (LLNL) Hazards Control Department for some time. The following four tests were proposed as necessary to provide complete evaluation of TECP suit performance: 1. Quantitative leak test (ASTM draft), 2. Worst-case chemical exposure test (conceptual), 3. Pressure leak-rate test (complete, ASTM F1057-87), and 4. Chemical leak-rate test (ASTM draft). This paper reports on these tests which should be applied to measuring TECP suit performance in two stages: design qualification tests and field use tests. Test 1, 2, and 3 are used as design qualification tests, and tests 3 and 4 are used as field use tests

  1. Freeze-thaw performance testing of whole concrete railroad ties.

    Science.gov (United States)

    2013-10-01

    Freezing and thawing durability tests of prestressed concrete ties are normally performed according to ASTM C666 specifications. Small specimens are cut from the shoulders of concrete ties and tested through 300 cycles of freezing and thawing. Saw-cu...

  2. 40 CFR 63.3360 - What performance tests must I conduct?

    Science.gov (United States)

    2010-07-01

    ... gaseous non-methane organic matter concentration. Use the same test method for both the inlet and outlet... exchange occurs. (B) Use the data collected during the performance test to calculate and record the average..., the outlet of the last control device in the series, and all intermediate streams (e.g., gaseous...

  3. Data collection and analysis software development for rotor dynamics testing in spin laboratory

    Science.gov (United States)

    Abdul-Aziz, Ali; Arble, Daniel; Woike, Mark

    2017-04-01

    Gas turbine engine components undergo high rotational loading another complex environmental conditions. Such operating environment leads these components to experience damages and cracks that can cause catastrophic failure during flights. There are traditional crack detections and health monitoring methodologies currently being used which rely on periodic routine maintenances, nondestructive inspections that often times involve engine and components dis-assemblies. These methods do not also offer adequate information about the faults, especially, if these faults at subsurface or not clearly evident. At NASA Glenn research center, the rotor dynamics laboratory is presently involved in developing newer techniques that are highly dependent on sensor technology to enable health monitoring and prediction of damage and cracks in rotor disks. These approaches are noninvasive and relatively economical. Spin tests are performed using a subscale test article mimicking turbine rotor disk undergoing rotational load. Non-contact instruments such as capacitive and microwave sensors are used to measure the blade tip gap displacement and blade vibrations characteristics in an attempt develop a physics based model to assess/predict the faults in the rotor disk. Data collection is a major component in this experimental-analytical procedure and as a result, an upgrade to an older version of the data acquisition software which is based on LabVIEW program has been implemented to support efficiently running tests and analyze the results. Outcomes obtained from the tests data and related experimental and analytical rotor dynamics modeling including key features of the updated software are presented and discussed.

  4. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Science.gov (United States)

    2010-04-01

    ... OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs... Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. (a) Over-the-counter (OTC) test sample collection systems for drugs of abuse testing (§ 864.3260...

  5. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Science.gov (United States)

    2010-07-01

    ... evaluations, and performance evaluations must I conduct? 63.2354 Section 63.2354 Protection of Environment... tests, design evaluations, and performance evaluations must I conduct? (a)(1) For each performance test... procedures specified in subpart SS of this part. (3) For each performance evaluation of a continuous emission...

  6. The data collection system for failure/maintenance at the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Casey, M.A.; Gruetzmacher, K.M.; Bartlit, J.R.; Cadwallader, L.C.

    1988-01-01

    A data collection system for obtaining information which can be used to help determine the reliability and vailability of future fusion power plants has been installed at the Los Alamos National Laboratory's Tritium Systems Test Assembly (TSTA). Failure and maintenance data on components of TSTA's tritium systems have been collected since 1984. The focus of the data collection has been TSTA's Tritium Waste Tratment System (TWT), which has maintained high availability since it became operation in 1982. Data collection is still in progress and a total of 291 failure reports are in the data collection system at this time, 47 of which are from the TWT. 6 refs., 2 figs., 2 tabs

  7. 40 CFR 63.309 - Performance tests and procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Performance tests and procedures. 63.309 Section 63.309 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Standards for Coke Oven Batteries § 63.309 Performance tests and procedures. (a) Except as otherwise...

  8. Beam test performance of the SKIROC2 ASIC

    CERN Document Server

    Frisson, T; Anduze, M; Augustin, J.E; Bonis, J; Boudry, V; Bourgeois, C; Brient, J.C; Callier, S; Cerutti, M; Chen, S; Cornat, R; Cornebise, P; Cuisy, D; David, J; De la Taille, C; Dulucq, F; Frotin, M; Gastaldi, F; Ghislain, P; Giraud, J; Gonnin, A; Grondin, D; Guliyev, E; Hostachy, J.Y; Jeans, D; Kamiya, Y; Kawagoe, K; Kozakai, C; Lacour, D; Lavergne, L; Lee, S.H; Magniette, F; Ono, H; Poeschl, R; Rouëné, J; Seguin-Moreau, N; Song, H.S; Sudo, Y; Thiebault, A; Tran, H; Ueno, H; Van der Kolk, N; Yoshioka, T

    2015-01-01

    Beam tests of the first layers of CALICE silicon tungsten ECAL technological prototype were performed in April and July 2012 using 1–6 GeV electron beam at DESY. This paper presents an analysis of the SKIROC2 readout ASIC performance under test beam conditions.

  9. Towards Smart Buildings Performance Testing as a Service

    DEFF Research Database (Denmark)

    Markoska, Elena; Lazarova-Molnar, Sanja

    2018-01-01

    to buildings’ energy consumption. In this paper we propose a methodology for continuous performance testing of smart buildings as a service. We discuss the automatic discovery and instantiation of performance tests, as well as usage of results for discovery of potential faults and ways to improve buldings...

  10. Impact of Educational Level on Performance on Auditory Processing Tests.

    Science.gov (United States)

    Murphy, Cristina F B; Rabelo, Camila M; Silagi, Marcela L; Mansur, Letícia L; Schochat, Eliane

    2016-01-01

    Research has demonstrated that a higher level of education is associated with better performance on cognitive tests among middle-aged and elderly people. However, the effects of education on auditory processing skills have not yet been evaluated. Previous demonstrations of sensory-cognitive interactions in the aging process indicate the potential importance of this topic. Therefore, the primary purpose of this study was to investigate the performance of middle-aged and elderly people with different levels of formal education on auditory processing tests. A total of 177 adults with no evidence of cognitive, psychological or neurological conditions took part in the research. The participants completed a series of auditory assessments, including dichotic digit, frequency pattern and speech-in-noise tests. A working memory test was also performed to investigate the extent to which auditory processing and cognitive performance were associated. The results demonstrated positive but weak correlations between years of schooling and performance on all of the tests applied. The factor "years of schooling" was also one of the best predictors of frequency pattern and speech-in-noise test performance. Additionally, performance on the working memory, frequency pattern and dichotic digit tests was also correlated, suggesting that the influence of educational level on auditory processing performance might be associated with the cognitive demand of the auditory processing tests rather than auditory sensory aspects itself. Longitudinal research is required to investigate the causal relationship between educational level and auditory processing skills.

  11. DEVELOPING an ENGLISH PERFORMANCE TEST for INCOMING INDONESIAN COLLEGE STUDENTS

    Directory of Open Access Journals (Sweden)

    Bill Glenny Wullur

    2011-07-01

    Full Text Available Abstracts This study constructed, developed and validated an English Performance test as a complementary to an existing placement test in Universitas Klabat, Manado, Indonesia.  It is designed to provide a valid criterion-based measurement within the placement programs of the said university. The study aimed to answer the following questions: (1 What test tasks and items are needed in a performance test based on current language testing theory? (2 Is the performance test valid? (3 Is the scoring of the performance test reliable? (4 Is the performance test practical and predictive? And (5 What are the ratings of the resultant performance test? The steps in developing a performance test involved conducting needs analysis, establishing attributes of good performance test, and constructing test specification based on current language testing theory.  The speech event chosen which would generate language use was applying for financial assistance.  From this speech event, four activities were elicited: (1 writing a letter of inquiry, (2 completing an application form, (3 making an appointment for interview, (4 giving an oral presentation/interview.  These activities represent the four authentic tasks in which the desirable modes/channel of communication, language functions and skills, genre, and topic are integrated. The developed test is divided into four sections corresponding with the elicited tasks: (1 Formal letter, (2 Application form, (3 Making Appointment, and (4 Oral Presentation. The test was validated in several ways: (1 face validation compared the scores of Indonesian studying in the Philippines and in Indonesia, and found that the scores are highly correlated at Spearman ρ = .85.  (2 The content validation relied on the evaluation of expert informants.  The finding shows that the content coverage and relevance of the test is highly satisfactory. (3 The concurrent validation was conducted to the existing placement test and found

  12. The influence of shyness on children's test performance.

    Science.gov (United States)

    Crozier, W Ray; Hostettler, Kirsten

    2003-09-01

    Research has shown that shy children differ from their peers not only in their use of language in routine social encounters but also in formal assessments of their language development, including psychometric tests of vocabulary. There has been little examination of factors contributing to these individual differences. To investigate cognitive-competence and social anxiety interpretations of differences in children's performance on tests of vocabulary. To examine the performance of shy and less shy children under different conditions of test administration, individually with an examiner or among their peers within the familiar classroom setting. The sample consisted of 240 Year 5 pupils (122 male, 118 female) from 24 primary schools. Shy and less shy children, identified by teacher nomination and checklist ratings, completed vocabulary and mental arithmetic tests in one of three conditions, in a between-subjects design. The conditions varied individual and group administration, and oral and written responses. The conditions of test administration influenced the vocabulary test performance of shy children. They performed significantly more poorly than their peers in the two face-to-face conditions but not in the group test condition. A comparable trend for the arithmetic test was not statistically significant. Across the sample as a whole, shyness correlated significantly with test scores. Shyness does influence children's cognitive test performance and its impact is larger when children are tested face-to-face rather than in a more anonymous group setting. The results are of significance for theories of shyness and have implications for the assessment of schoolchildren.

  13. Performance testing framework for smart grid communication network

    International Nuclear Information System (INIS)

    Quang, D N; See, O H; Chee, L L; Xuen, C Y; Karuppiah, S

    2013-01-01

    Smart grid communication network is comprised of different communication mediums and technologies. Performance evaluation is one of the main concerns in smart grid communication system. In any smart grid communication implementation, to determine the performance factor of the network, a testing of an end-to-end process flow is required. Therefore, an effective and coordinated testing procedure plays a crucial role in evaluating the performance of smart grid communications. In this paper, a testing framework is proposed as a guideline to analyze and assess the performance of smart grid communication network.

  14. Timed Online Tests: Do Students Perform Better with More Time?

    Science.gov (United States)

    Portolese, Laura; Krause, Jackie; Bonner, Julie

    2016-01-01

    This article focuses on timed tests and specifically on whether increased time enhances test performance. Three courses during the Winter 2015 term (quizzes n = 573) and three courses over the Spring 2015 term (quizzes n = 600) comprised this sample. Students were given the same tests, but the experimental group (Spring 2015) was given 50% more…

  15. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    /10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus...

  16. Item Response Theory Models for Performance Decline during Testing

    Science.gov (United States)

    Jin, Kuan-Yu; Wang, Wen-Chung

    2014-01-01

    Sometimes, test-takers may not be able to attempt all items to the best of their ability (with full effort) due to personal factors (e.g., low motivation) or testing conditions (e.g., time limit), resulting in poor performances on certain items, especially those located toward the end of a test. Standard item response theory (IRT) models fail to…

  17. High Performance Computing Modernization Program Kerberos Throughput Test Report

    Science.gov (United States)

    2017-10-26

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/5524--17-9751 High Performance Computing Modernization Program Kerberos Throughput Test ...NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2. REPORT TYPE1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 6. AUTHOR(S) 8. PERFORMING...PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT High Performance Computing Modernization Program Kerberos Throughput Test Report Daniel G. Gdula* and

  18. FedWeb Greatest Hits: Presenting the New Test Collection for Federated Web Search

    NARCIS (Netherlands)

    Demeester, Thomas; Trieschnigg, Rudolf Berend; Zhou, Ke; Nguyen, Dong-Phuong; Hiemstra, Djoerd

    This paper presents 'FedWeb Greatest Hits', a large new test collection for research in web information retrieval. As a combination and extension of the datasets used in the TREC Federated Web Search Track, this collection opens up new research possibilities on federated web search challenges, as

  19. Irradiation test and performance evaluation of DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Song, K. C.; Moon, J. S.

    2002-05-01

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  20. Model tests on dynamic performance of RC shear walls

    International Nuclear Information System (INIS)

    Nagashima, Toshio; Shibata, Akenori; Inoue, Norio; Muroi, Kazuo.

    1991-01-01

    For the inelastic dynamic response analysis of a reactor building subjected to earthquakes, it is essentially important to properly evaluate its restoring force characteristics under dynamic loading condition and its damping performance. Reinforced concrete shear walls are the main structural members of a reactor building, and dominate its seismic behavior. In order to obtain the basic information on the dynamic restoring force characteristics and damping performance of shear walls, the dynamic test using a large shaking table, static displacement control test and the pseudo-dynamic test on the models of a shear wall were conducted. In the dynamic test, four specimens were tested on a large shaking table. In the static test, four specimens were tested, and in the pseudo-dynamic test, three specimens were tested. These tests are outlined. The results of these tests were compared, placing emphasis on the restoring force characteristics and damping performance of the RC wall models. The strength was higher in the dynamic test models than in the static test models mainly due to the effect of loading rate. (K.I.)

  1. The Performance test of Mechanical Sodium Pump with Water Environment

    International Nuclear Information System (INIS)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Jeong, Ji-Young; Kim, Jong-Bum; Ko, Bock Seong; Park, Sang Jun; Lee, Yoon Sang

    2015-01-01

    As contrasted with PWR(Pressurized light Water Reactor) using water as a coolant, sodium is used as a coolant in SFR because of its low melting temperature, high thermal conductivity, the high boiling temperature allowing the reactors to operate at ambient pressure, and low neutron absorption cross section which is required to achieve a high neutron flux. But, sodium is violently reactive with water or oxygen like the other alkali metal. So Very strict requirements are demanded to design and fabricate of sodium experimental facilities. Furthermore, performance testing in high temperature sodium environments is more expensive and time consuming and need an extra precautions because operating and maintaining of sodium experimental facilities are very difficult. The present paper describes performance test results of mechanical sodium pump with water which has been performed with some design changes using water test facility in SAM JIN Industrial Co. To compare the hydraulic characteristic of model pump with water and sodium, the performance test of model pump were performed using vender's experimental facility for mechanical sodium pump. To accommodate non-uniform thermal expansion and to secure the operability and the safety, the gap size of some parts of original model pump was modified. Performance tests of modified mechanical sodium pump with water were successfully performed. Water is therefore often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Normal practice to thoroughly test a design or component before applied or installed in reactor is important to ensure the safety and operability in the sodium-cooled fast reactor (SFR). So, in order to estimate the hydraulic behavior of the PHTS pump of DSFR (600 MWe Demonstraion SFR), the performance tests of the model pump such as performance

  2. The Empirical Testing of a Musical Performance Assessment Paradigm

    Science.gov (United States)

    Russell, Brian E.

    2010-01-01

    The purpose of this study was to test a hypothesized model of aurally perceived performer-controlled musical factors that influence assessments of performance quality. Previous research studies on musical performance constructs, musical achievement, musical expression, and scale construction were examined to identify the factors that influence…

  3. Test Report Emission Test Program EPA Information Collection Request for Delayed Coking Units 736 Coker Unit

    Science.gov (United States)

    ARI Environmental, Inc. (ARI) was retained by Houston Refining LP (HRO) to conduct an emission test program at their refinery located in Houston, Texas. The testing was conducted on on the 736 Delayed Coking Unit (DCU) in response to EPA's ICR.

  4. Mechanical/structural performance test method of a spacer grid

    International Nuclear Information System (INIS)

    Yoon, Kyung Ho

    2000-06-01

    The spacer grid is one of the main structural components in the fuel assembly, which supports the fuel rods, guides cooling water, and protects the system from an external impact load, such as earthquakes. In order to develop the spacer grid with the high mechanical performance, the mechanical and structural properties of the spacer grids must be extensively examined while designing it. In this report, the mechanical/structural test methods, i.e. the characteristic test of a spacer grid spring or dimple, static buckling test of a partial or full size spacer grid and dynamic impact test of them are described. The characteristic test of a spacer grid spring or dimple is accomplished with universal tensile test machine, a specimen is fixed with test fixture and then applied compressive load. The characteristic test data is saved at loading and unloading event. The static buckling test of a partial or full size spacer grid is executed with the same universal tensile testing machine, a specimen is fixed between cross-heads and then applied the compressive load. The buckling strength is decided the maximum strength at load vs. displacement curve. The dynamic impact test of a partial or full size spacer grid is performed with pendulum type impact machine and free fall shock test machine, a specimen is fixed with test fixture and then applied the impact load by impact hammer. Specially, the pendulum type impact test machine is also possible under the operating temperature because a furnace is separately attached with test machine

  5. Important Details in Performing and Interpreting the Scratch Collapse Test.

    Science.gov (United States)

    Kahn, Lorna C; Yee, Andrew; Mackinnon, Susan E

    2018-02-01

    The utility of the scratch collapse test has been demonstrated in examination of patients with carpal and cubital tunnel syndromes and long thoracic and peroneal nerve compressions. In the authors' clinic, this lesser known test plays a key role in peripheral nerve examination where localization of the nerve irritation or injury is not fully understood. Test utility and accuracy in patients with more challenging presentations likely correlate with tester understanding and experience. This article offers a clear outline of all stages of the test to improve interrater reliability. The nuances of test performance are described, including a description of situations where the scratch collapse test is deemed inappropriate. Four clinical scenarios where the scratch collapse test may be useful are included. Corresponding video content is provided to improve performance and interpretation of the scratch collapse test. Diagnostic, V.

  6. 40 CFR 63.344 - Performance test requirements and test methods.

    Science.gov (United States)

    2010-07-01

    ... electroplating tanks or chromium anodizing tanks. The sampling time and sample volume for each run of Methods 306... Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test... Emissions From Decorative and Hard Chromium Electroplating and Anodizing Operations,” appendix A of this...

  7. Expectancy of an open-book test decreases performance on a delayed closed-book test.

    Science.gov (United States)

    Agarwal, Pooja K; Roediger, Henry L

    2011-11-01

    Two experiments examined the influence of practice with, and the expectancy of, open-book tests (students viewed studied material while taking the test) versus closed-book tests (students completed the test without viewing the studied material) on delayed retention and transfer. Using GRE materials specifically designed for open-book testing, participants studied passages and then took initial open- or closed-book tests. Open-book testing led to better initial performance than closed-book testing, but on a delayed criterial (closed-book) test both types of testing produced similar retention after a two-day delay in Experiment 1. In Experiment 2 participants were informed in advance about the type of delayed criterial test to expect (open- or closed-book). Expecting an open-book test (relative to a closed-book test) decreased participants' time spent studying and their delayed test performance on closed-book comprehension and transfer tests, demonstrating that test expectancy can influence long-term learning. Expectancy of open-book tests may impair long-term retention and transfer compared to closed-book tests, despite superior initial performance on open-book tests and students' preference for open-book tests.

  8. Nuclebras' installations for performance tests of nuclear power plants components

    International Nuclear Information System (INIS)

    Vasconcelos Paiva, I.P. de; Avelar Esteves, F. de; Horta, J.A.L.; Resende, M.F.R.; Pinheiro, R.B.

    1984-01-01

    The reasons for Nuclebras' Nuclear Technology Development Center to implement a laboratory for supporting Brazilian manufactures, giving to them the means for performing functional tests of industrial products, are presented. A brief description of facilities under construction: the components Test Loop and Facility for Testing N.P.P. components under Accident conditions, and other already in operation, as well as its objectives and main technical characteristics. Some test results had already obtained are also presented. (Author) [pt

  9. A Framework for Fully Automated Performance Testing for Smart Buildings

    DEFF Research Database (Denmark)

    Markoska, Elena; Johansen, Aslak; Lazarova-Molnar, Sanja

    2018-01-01

    , setup of performance tests has been manual and labor-intensive and has required intimate knowledge of buildings’ complexity and systems. The emergence of the concept of smart buildings has provided an opportunity to overcome this restriction. In this paper, we propose a framework for automated......A significant proportion of energy consumption by buildings worldwide, estimated to ca. 40%, has yielded a high importance to studying buildings’ performance. Performance testing is a mean by which buildings can be continuously commissioned to ensure that they operate as designed. Historically...... performance testing of smart buildings that utilizes metadata models. The approach features automatic detection of applicable performance tests using metadata queries and their corresponding instantiation, as well as continuous commissioning based on metadata. The presented approach has been implemented...

  10. Test anxiety, perfectionism, goal orientation, and academic performance.

    Science.gov (United States)

    Eum, KoUn; Rice, Kenneth G

    2011-03-01

    Dimensions of perfectionism and goal orientation have been reported to have differential relationships with test anxiety. However, the degree of inter-relationship between different dimensions of perfectionism, the 2 × 2 model of goal orientations proposed by Elliot and McGregor, cognitive test anxiety, and academic performance indicators is not known. Based on data from 134 university students, we conducted correlation and regression analyses to test associations between adaptive and maladaptive perfectionism, four types of goal orientations, cognitive test anxiety, and two indicators of academic performance: proximal cognitive performance on a word list recall test and distal academic performance in terms of grade point average. Cognitive test anxiety was inversely associated with both performance indicators, and positively associated with maladaptive perfectionism and avoidance goal orientations. Adaptive and maladaptive perfectionism accounted for significant variance in cognitive test anxiety after controlling for approach and avoidance goal orientations. Overall, nearly 50% of the variance in cognitive test anxiety could be attributed to gender, goal orientations, and perfectionism. Results suggested that students who are highly test anxious are likely to be women who endorse avoidance goal orientations and are maladaptively perfectionistic.

  11. Exploration of task performance tests in a physics laboratory

    Science.gov (United States)

    Liu, Dan; El Turkey, Houssein

    2017-11-01

    In this article, we investigate the implementation of task performance tests in an undergraduate physics laboratory. Two performance tests were carried out over two semesters using the task of building a DC circuit. The first implementation in Spring 2014 had certain concerns such as the privacy of students’ testing and their ‘trial and error’ attempts. These concerns were addressed in Fall 2015 through implementing a second performance test. The second implementation was administered differently but the content of the two tests was the same. We discuss the validity of both implementations and present the correlation (or lack of) between the time that students needed to complete the tests and their grades from a paper-based laboratory assessment method.

  12. Personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, Christopher G.

    2008-01-01

    The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11. Now in it's fourth edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Laboratory Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by U.S. Nuclear Regulatory Commission (NRC) regulations. The U.S. Department of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Department of Energy Laboratory Accreditation Program (DOELAP). One of the goals of this current revision was the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonization to U.S. personal dosemeter performance testing. The testing philosophy of ANSI/HPS N13.11 has always combined elements of type testing and routine performance testing and is thus different from the testing philosophy used in the rest of the world. In this paper, the history of performance testing in the U.S. is briefly reviewed. Also described is the revision that produced the fourth edition of this standard, which has taken place over the last three years (2005-2008) by a working group representing national standards laboratories, government laboratories, the military, dosimetry vendors, universities and the nuclear power industry. (author)

  13. The study of the energetic performance in test cycles

    Science.gov (United States)

    Rentea, Cristian; Tuca, Alexandra; Oprean, Mircea; Marius, Bataus

    2017-10-01

    One of the most important subsystems of modern passenger cars is the transmission. This paper aims to investigate the global performances of a modern transmission in different test cycles including the newly introduced WLTC (Worldwide Harmonized Light Vehicles Test Cycle). The study is done using a complex model developed in a performant simulation environment. Transmission efficiency calculation is emphasized, the efficiency being considered variable depending on engine torque, engine speed and gear ratio. The main important parameters (vehicle speed fluctuation, overall transmission efficiency, fuel consumption ratio) needed to compare test cycles and the transmissions performance are determined.

  14. Performance Testing Methodology for Safety-Critical Programmable Logic Controller

    International Nuclear Information System (INIS)

    Kim, Chang Ho; Oh, Do Young; Kim, Ji Hyeon; Kim, Sung Ho; Sohn, Se Do

    2009-01-01

    The Programmable Logic Controller (PLC) for use in Nuclear Power Plant safety-related applications is being developed and tested first time in Korea. This safety-related PLC is being developed with requirements of regulatory guideline and industry standards for safety system. To test that the quality of the developed PLC is sufficient to be used in safety critical system, document review and various product testings were performed over the development documents for S/W, H/W, and V/V. This paper provides the performance testing methodology and its effectiveness for PLC platform conducted by KOPEC

  15. Recommended procedures for performance testing of radiobioassay laboratories: Volume 3, In vivo test phantoms

    International Nuclear Information System (INIS)

    MacLellan, J.A.; Traub, R.J.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard describes the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay performance-testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the draft ANSI N13.30 performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of test phantoms used for calibration of measurement systems for direct bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented

  16. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    We identify one potential source of bias that influences children’s performance on standardized tests and that is predictable based on psychological theory: the time at which students take the test. Using test data for all children attending Danish public schools between school years 2009....../10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus......, as the day wears on, students become increasingly fatigued and consequently more likely to underperform on a standardized test....

  17. Collection performance: an empirical analysis of not-for-profit community hospitals.

    Science.gov (United States)

    Prince, T R; Ramanan, R

    1992-01-01

    Many not-for-profit community hospitals had major shifts in their annual collection performance between 1986 and 1988. The collection performance is measured by excess collection time; this is computed as the difference between the actual average collection time for a hospital and the median for one of the six panels to which the hospital is assigned based on ownership, control code, and financial reporting practices. The sample for this study has 1,246 not-for-profit hospitals comprising over 50 percent of total revenue and expenses of all community hospitals (about 5,500). More than 16 percent of these hospitals had annual changes of ten-plus days in each of the years. Excess collection time within the six panels was examined by state, payer mix (Medicare, Medicaid, and Blue Cross), membership in the Council of Teaching Hospitals, medical school affiliation, case-mix index for Medicare, contractual allowance rate, debt-service coverage, return on assets, new investments, age of property, and urban location. Major findings were that collection patterns are different among some states. The proportions of Medicare, Medicaid, and Blue Cross are negatively associated with excess collection time in three of the panels. Contractual allowance is positively related, and return on assets is negatively associated with excess collection time in two of the panels. The other factors had virtually no effect on the collection performance.

  18. The Relationship between University Libraries' Collection for Sports and Their Students' Sports Performances

    Science.gov (United States)

    Nagami, Soichiro; Tsuji, Keita

    2011-01-01

    To demonstrate the effectiveness of university libraries, we investigated the relationship between university students' sports performances and their libraries collections of sports. By examining approximately 20 university libraries' collections and their sports ranks, as indicated by Waseda Sports 2008, we demonstrated their positive…

  19. Strengthening Collective Action to Improve Marketing Performance: Evidence from Farmer Groups in Central Africa

    Science.gov (United States)

    Ochieng, Justus; Knerr, Beatrice; Owuor, George; Ouma, Emily

    2018-01-01

    Purpose: Several development organisations have implemented programs to enhance smallholder farmers' crop productivity and market access through collective action with mixed results. Therefore, this study examines the drivers of success of collective action initiatives as a pathway to improving farmers marketing performance using data from Rwanda…

  20. 77 FR 33808 - Agency Information Collection; Activity Under OMB Review: Airline Service Quality Performance...

    Science.gov (United States)

    2012-06-07

    ... DEPARTMENT OF TRANSPORTATION Research & Innovative Technology Administration [Docket ID Number RITA 2008-0002] Agency Information Collection; Activity Under OMB Review: Airline Service Quality.... SUPPLEMENTARY INFORMATION: OMB Approval No. 2138-0041 Title: Airline Service Quality Performance -Part 234. Form...

  1. Investigating Conversational Dynamics: Interactive Alignment, Interpersonal Synergy, and Collective Task Performance

    Science.gov (United States)

    Fusaroli, Riccardo; Tylén, Kristian

    2016-01-01

    This study investigates interpersonal processes underlying dialog by comparing two approaches, "interactive alignment" and "interpersonal synergy", and assesses how they predict collective performance in a joint task. While the interactive alignment approach highlights imitative patterns between interlocutors, the synergy…

  2. Development of evaluation methodology to assess the sodium fire suppression performance of leak collection tray

    International Nuclear Information System (INIS)

    Parida, F.C.; Rao, P.M.; Ramesh, S.S.; Somayajulu, P.A.; Malarvizhi, B.; Kannan, S.E.

    2005-01-01

    Full text of publication follows: Leakage of hot liquid sodium and its subsequent combustion in the form of a pool cannot be completely ruled out in a Fast breeder Reactor (FBR) plant in spite of provision for adequate safety measures. To protect the plant system from the hazardous effects of flame, heat and smoke, one of the passive protection devices used in FBR plants is the Leak Collection Tray (LCT). The design of LCT is based on immediate channeling of burning liquid sodium on the funnel shaped sloping cover tray (SCT) to the bottom sodium hold-up vessel (SHV) in which self-extinction of the fire occurs due to oxygen starvation. The SCT has one or three drain pipes and air vent pipes depending on the type of design. In each experiment, a known amount ranging from 30 to 40 kg of hot liquid sodium at 550 deg. C was discharged on the LCT in the open air. Continuous on-line monitoring of temperature at strategic locations (∼ 28 points) was carried out. Colour video-graphy was employed for taking motion pictures of various time-dependent events like sodium dumping, appearance of flame and release of smoke through vent pipes. After self-extinction of sodium fire, the LCT was allowed to cool overnight in an argon atmosphere. Solid samples of sodium debris in the SCT and SHV were collected by manual core drilling machine. The samples were subjected to chemical analysis for determination of unburnt and burnt sodium. The sodium debris removed from SCT and SHV were separately weighed. To assess the performance of the LCT, two different geometrical configurations of SCT, one made up of stainless steel an the other of carbon steel, were used. Three broad phenomena are identified as the basis of evaluation methodology. These are (a) thermal transients, i.e. heating and cooling of the bulk sodium in SCT and SHV respectively, (b) post test sodium debris distribution between SCT and SHV as well as (c) sodium combustion and smoke release behaviour. Under each category

  3. Development of evaluation methodology to assess the sodium fire suppression performance of leak collection tray

    Energy Technology Data Exchange (ETDEWEB)

    Parida, F.C.; Rao, P.M.; Ramesh, S.S.; Somayajulu, P.A.; Malarvizhi, B.; Kannan, S.E. [Engineering Safety Division, Safety Group, Indira Gandhi Centre for Atomic Research, Kalpakkam - 603102, Tamilnadu (India)

    2005-07-01

    Full text of publication follows: Leakage of hot liquid sodium and its subsequent combustion in the form of a pool cannot be completely ruled out in a Fast breeder Reactor (FBR) plant in spite of provision for adequate safety measures. To protect the plant system from the hazardous effects of flame, heat and smoke, one of the passive protection devices used in FBR plants is the Leak Collection Tray (LCT). The design of LCT is based on immediate channeling of burning liquid sodium on the funnel shaped sloping cover tray (SCT) to the bottom sodium hold-up vessel (SHV) in which self-extinction of the fire occurs due to oxygen starvation. The SCT has one or three drain pipes and air vent pipes depending on the type of design. In each experiment, a known amount ranging from 30 to 40 kg of hot liquid sodium at 550 deg. C was discharged on the LCT in the open air. Continuous on-line monitoring of temperature at strategic locations ({approx} 28 points) was carried out. Colour video-graphy was employed for taking motion pictures of various time-dependent events like sodium dumping, appearance of flame and release of smoke through vent pipes. After self-extinction of sodium fire, the LCT was allowed to cool overnight in an argon atmosphere. Solid samples of sodium debris in the SCT and SHV were collected by manual core drilling machine. The samples were subjected to chemical analysis for determination of unburnt and burnt sodium. The sodium debris removed from SCT and SHV were separately weighed. To assess the performance of the LCT, two different geometrical configurations of SCT, one made up of stainless steel an the other of carbon steel, were used. Three broad phenomena are identified as the basis of evaluation methodology. These are (a) thermal transients, i.e. heating and cooling of the bulk sodium in SCT and SHV respectively, (b) post test sodium debris distribution between SCT and SHV as well as (c) sodium combustion and smoke release behaviour. Under each category

  4. Acceptability of Sexually Transmitted Infection Testing Using Self-Collected Vaginal Swabs among College Women

    Science.gov (United States)

    Fielder, Robyn L.; Carey, Kate B.; Carey, Michael P.

    2013-01-01

    Objective: To assess the acceptability of sexually transmitted infection (STI) testing using self-collected vaginal swabs (SCVS) among college women. Participants: First-year female students ("N" = 483). Methods: Participants were offered free testing for 3 STIs using SCVS in April 2010 and later completed a survey regarding their…

  5. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of ... Conclusion: Acceptability of self-sampling for HPV testing was similarly excellent in both groups despite their difference in terms ... cancer is the leading cause of death caused by cancer in.

  6. A guide to archival collections relating to radioactive fallout from nuclear weapon testing

    International Nuclear Information System (INIS)

    Martin, B.W.

    1992-09-01

    This ninth edition of A Guide to Archival Collections Relating to Radioactive Fallout from Nuclear Weapon Testing constitutes History Associates Incorporated's (HAI) final report of its document collection, processing, and declassification efforts for the Nevada Field Office of the Department of Energy. The most significant feature of this edition is the updated HAI collection effort information. We confirmed the accuracy of this information using our screening, processing, and transmittal records. Unlike previous editions, funding limitations prevented us from systematically revising the collection descriptions and point-of-contact information for this final edition. This guide has been prepared by professional historians who have a working knowledge of many of the record collections included in the following pages. In describing materials, they have tried to include enough information so that persons unfamiliar with the complexities of large record systems will be able to determine that nature of the information in, and the quality of, each record collection

  7. Performance Test of Parabolic Trough Solar Cooker for Indoor ...

    African Journals Online (AJOL)

    Bheema

    mm diameter copper pipe is the optimum size for the absorber. Maximum temperatures of ... This paper deals with improving and testing performance of a concentrating cooker for indoor cooking with ... bean oil Soya bean oil. Coating material.

  8. Round robin performance testing of organic photovoltaic devices

    DEFF Research Database (Denmark)

    Gevorgyan, Suren; Zubillaga, Oihana; de Seoane, José María Vega

    2014-01-01

    This study addresses the issue of poor intercomparability of measurements of organic photovoltaic (OPV) devices among different laboratories. We present a round robin performance testing of novel OPV devices among 16 laboratories, organized within the framework of European Research Infrastructure...

  9. Corrosion performance tests for reinforcing steel in concrete : technical report.

    Science.gov (United States)

    2009-10-01

    The existing test method used to assess the corrosion performance of reinforcing steel embedded in : concrete, mainly ASTM G 109, is labor intensive, time consuming, slow to provide comparative results, : and can be expensive. However, with corrosion...

  10. Model for the separate collection of packaging waste in Portuguese low-performing recycling regions.

    Science.gov (United States)

    Oliveira, V; Sousa, V; Vaz, J M; Dias-Ferreira, C

    2018-06-15

    Separate collection of packaging waste (glass; plastic/metals; paper/cardboard), is currently a widespread practice throughout Europe. It enables the recovery of good quality recyclable materials. However, separate collection performance are quite heterogeneous, with some countries reaching higher levels than others. In the present work, separate collection of packaging waste has been evaluated in a low-performance recycling region in Portugal in order to investigate which factors are most affecting the performance in bring-bank collection system. The variability of separate collection yields (kg per inhabitant per year) among 42 municipalities was scrutinized for the year 2015 against possible explanatory factors. A total of 14 possible explanatory factors were analysed, falling into two groups: socio-economic/demographic and waste collection service related. Regression models were built in an attempt to evaluate the individual effect of each factor on separate collection yields and predict changes on the collection yields by acting on those factors. The best model obtained is capable to explain 73% of the variation found in the separate collection yields. The model includes the following statistically significant indicators affecting the success of separate collection yields: i) inhabitants per bring-bank; ii) relative accessibility to bring-banks; iii) degree of urbanization; iv) number of school years attended; and v) area. The model presented in this work was developed specifically for the bring-bank system, has an explanatory power and quantifies the impact of each factor on separate collection yields. It can therefore be used as a support tool by local and regional waste management authorities in the definition of future strategies to increase collection of recyclables of good quality and to achieve national and regional targets. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. RELATIONSHIPS BETWEEN FUNCTIONAL MOVEMENT TESTS AND PERFORMANCE TESTS IN YOUNG ELITE MALE BASKETBALL PLAYERS.

    Science.gov (United States)

    Gonzalo-Skok, Oliver; Serna, Jorge; Rhea, Matthew R; Marín, Pedro J

    2015-10-01

    Sprinting and jumping are two common and important components of high-level sport performance. The weight-bearing dorsiflexion test (WB-DF) and Star Excursion Balance Test (SEBT) are tools developed to identify athletes at risk for lower extremity injury and may be related to running and jumping performance among athletes. The purposes of the present study were: 1) to identify any relationships between functional movement tests (WB-DF and SEBT) and performance tests (jumping, sprinting and changing direction); 2) to examine any relationships between asymmetries in functional movements and performance tests. Descriptive cohort study. Fifteen elite male basketball players (age: 15.4 ± 0.9 years) were assessed during a three-week period to determine the reliability of functional screening tools and performance tests and to examine the relationships between these tests. Relative (intraclass correlation coefficient) and absolute (coefficient of variation) reliability were used to assess the reproducibility of the tests. Significant correlations were detected between certain functional movement tests and performance tests. Both left and right excursion composite scores related to slower performance times in sprint testing, demonstrating that greater dynamic reach relates to decreased quickness and acceleration among these elite basketball athletes. The various relationships between dynamic functional movement testing, speed, and jump performance provide guidance for the strength and conditioning professional when conducting and evaluating data in an effort to improve performance and reduce risk of injury. The results of the present study suggest that these functional and performance tests do not measure the same components of human movement, and could be paired as outcome measures for the clinical and sport assessment of lower extremity function. 2b.

  12. Wind Tunnel and Hover Performance Test Results for Multicopter UAS Vehicles

    Science.gov (United States)

    Russell, Carl R.; Jung, Jaewoo; Willink, Gina; Glasner, Brett

    2016-01-01

    There is currently a lack of published data for the performance of multicopter unmanned aircraft system (UAS) vehicles, such as quadcopters and octocopters, often referred to collectively as drones. With the rapidly increasing popularity of multicopter UAS, there is interest in better characterizing the performance of this type of aircraft. By studying the performance of currently available vehicles, it will be possible to develop models for vehicles at this scale that can accurately predict performance and model trajectories. This paper describes a wind tunnel test that was recently performed in the U.S. Army's 7- by 10-ft Wind Tunnel at NASA Ames Research Center. During this wind tunnel entry, five multicopter UAS vehicles were tested to determine forces and moments as well as electrical power as a function of wind speed, rotor speed, and vehicle attitude. The test is described here in detail, and a selection of the key results from the test is presented.

  13. Fracture testing and performance of beryllium copper alloy C 17510

    International Nuclear Information System (INIS)

    Murray, H.A.; Zatz, I.J.

    1992-01-01

    A series of test programs was undertaken on copper beryllium alloy C 17510 for several variations in material process and chemistry. These variations in C 17510 were primarily optimized for combinations of strength and conductivity. While originally intended for use as cyclically loaded high-field, high-strength conductors in fusion energy research, material testing of C 17510 has indicated that it is an attractive and economical alternative for a host of other structural, mechanical and electrical applications. ASTM tests performed on three variations of C 17510 alloys included both J-integral and plane strain fracture toughness testing (E813, E399) and fatigue crack growth rate tests (E647), as well as verifying tensile, hardness, Charpy, and other well defined mechanical properties. Fracture testing was performed at both room and liquid nitrogen temperatures, which bound the thermal environment anticipated for the fusion components being designed. Fatigue crack propagation stress ratios ranged from nominal zero to minus one at each temperature

  14. Human performance in nondestructive inspections and functional tests: Final report

    International Nuclear Information System (INIS)

    Harris, D.H.

    1988-10-01

    Human performance plays a vital role in the inspections and tests conducted to assure the physical integrity of nuclear power plants. Even when technically-sophisticated equipment is employed, the outcome is highly dependent on human control actions, calibrations, observations, analyses, and interpretations. The principal consequences of inadequate performance are missed or falsely-reported defects. However, the cost-avoidance that stems from addressing potential risks promptly, and the increasing costs likely with aging plants, emphasize that timeliness and efficiency are important inspection-performance considerations also. Human performance issues were studied in a sample of inspections and tests regularly conducted in nuclear power plants. These tasks, selected by an industry advisory panel, were: eddy-current inspection of steam-generator tubes; ultrasonic inspection of pipe welds; inservice testing of pumps and valves; and functional testing of shock suppressors. Information was obtained for the study from industry and plant procedural documents; training materials; research reports and related documents; interviews with training specialists, inspectors, supervisory personnel, and equipment designers; and first-hand observations of task performance. Eleven recommendations are developed for improving human performance on nondestructive inspections and functional tests. Two recommendations were for the more-effective application of existing knowledge; nine recommendations were for research projects that should be undertaken to assure continuing improvements in human performance on these tasks. 25 refs., 9 figs., 1 tab

  15. 42 CFR 84.103 - Man tests; performance requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests; performance requirements. 84.103 Section 84.103 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.103 Man tests;...

  16. Current Status and Performance Tests of Korea Heat Load Test Facility KoHLT-EB

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sukkwon; Jin, Hyunggon; Shin, Kyuin; Choi, Boguen; Lee, Eohwak; Yoon, Jaesung; Lee, Dongwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Duckhoi; Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    A commissioning test has been scheduled to establish the installation and preliminary performance experiments of the copper hypervapotron mockups. And a qualification test will be performed to evaluate the CuCrZr duct liner in the ITER neutral beam injection facility and the ITER first wall small-scale mockups of the semi-prototype, at up to 1.5 and 5 MW/m{sup 2} high heat flux. Also, this system will be used to test other PFCs for ITER and materials for tokamak reactors. Korean high heat flux test facility(KoHLT-EB; Korea Heat Load Test facility - Electron Beam) by using an electron beam system has been constructed in KAERI to perform the qualification test for ITER blanket FW semi-prototype mockups, hypervapotron cooling devices in fusion devices, and other ITER plasma facing components. The commissioning and performance tests with the supplier of e-gun system have been performed on November 2012. The high heat flux test for hypervapotron cooling device and calorimetry were performed to measure the surface heat flux, the temperature profile and cooling performance. Korean high heat flux test facility for the plasma facing components of nuclear fusion machines will be constructed to evaluate the performance of each component. This facility for the plasma facing materials will be equipped with an electron beam system with a 60 kV acceleration gun.

  17. Reverse translated and gold standard continuous performance tests predict global cognitive performance in schizophrenia.

    Science.gov (United States)

    Bismark, Andrew W; Thomas, Michael L; Tarasenko, Melissa; Shiluk, Alexandra L; Rackelmann, Sonia Y; Young, Jared W; Light, Gregory A

    2018-04-12

    Attentional dysfunction contributes to functional impairments in schizophrenia (SZ). Sustained attention is typically assessed via continuous performance tasks (CPTs), though many CPTs have limited cross-species translational validity and place demands on additional cognitive domains. A reverse-translated 5-Choice Continuous Performance Task (5C-CPT) for human testing-originally developed for use in rodents-was designed to minimize demands on perceptual, visual learning, processing speed, or working memory functions. To-date, no studies have validated the 5C-CPT against gold standard attentional measures nor evaluated how 5C-CPT scores relate to cognition in SZ. Here we examined the relationship between the 5C-CPT and the CPT-Identical Pairs (CPT-IP), an established and psychometrically robust measure of vigilance from the MATRICS Consensus Cognitive Battery (MCCB) in a sample of SZ patients (n = 35). Relationships to global and individual subdomains of cognition were also assessed. 5C-CPT and CPT-IP measures of performance (d-prime) were strongly correlated (r = 0.60). In a regression model, the 5C-CPT and CPT-IP collectively accounted for 54% of the total variance in MCCB total scores, and 27.6% of overall cognitive variance was shared between the 5C-CPT and CPT-IP. These results indicate that the reverse translated 5C-CPT and the gold standard CPT-IP index a common attentional construct that also significantly overlaps with variance in general cognitive performance. The use of simple, cross-species validated behavioral indices of attentional/cognitive functioning such as the 5C-CPT could accelerate the development of novel generalized pro-cognitive therapeutics for SZ and related neuropsychiatric disorders.

  18. S.S.T.O. performance assessment with in-flight lox collection

    Science.gov (United States)

    Vandenkerckhove, J.; Czysz, P.

    1995-10-01

    Much attention has recently been given, up to harware development to in-flight oxygen collection as a means to improve considerably the performance of both TSTO & SSTO vehicles. A first assessment suggests that it permits simultaneously to improve much both gross take-off weight (by more than 30%) & dry weight (by more than 15%) of an SSTO and to lower significantly the Mach number of transition scramjet → rocket, from 15 down below 10, thereby reducing dramatically the programmatic development risks. After having compared in-flight lox collection with other SSTO concepts, this paper provides a tentative assessment of the performance of SSTO vehicles taking advantage of it, in particular their sensitivity to changes in system characteristics such as transition Mach number, vehicle slenderness (i.e. Küchemann's parameter τ) or planform loading at take-off and in collection characteristics, in particular collection ratio & specific collection plant weight.

  19. Performances on Symbol Digit Modalities Test, Color Trails Test, and modified Stroop test in a healthy, elderly Danish sample

    DEFF Research Database (Denmark)

    Vogel, Asmus; Stokholm, Jette; Jørgensen, Kasper

    2013-01-01

    This study presents Danish data for the Symbol Digit Modalities Test (SDMT), Color Trails Test (CTT), and a modified Stroop test from 100 subjects aged 60-87 years. Among the included demographic variables, age had the highest impact on test performances. Thus, the study presents separate data...

  20. Performance test of a bladeless turbine for geothermal applications

    Energy Technology Data Exchange (ETDEWEB)

    Steidel, R.; Weiss, H.

    1976-03-24

    The Possell bladeless turbine was tested at the LLL Geothermal Test Facility to evaluate its potential for application in the total flow process. Test description and performance data are given for 3000, 3500, 4000, and 4500 rpm. The maximum engine efficiency observed was less than 7 percent. It is concluded that the Possell turbine is not a viable candidate machine for the conversion of geothermal fluids by the total flow process. (LBS)

  1. Preliminary results of testing bioassay analytical performance standards

    International Nuclear Information System (INIS)

    Fisher, D.R.; Robinson, A.V.; Hadley, R.T.

    1983-08-01

    The analytical performance of both in vivo and in vitro bioassay laboratories is being studied to determine the capability of these laboratories to meet the minimum criteria for accuracy and precision specified in the draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. This paper presents preliminary results of the first round of testing

  2. Effects of Vigorous Intensity Physical Activity on Mathematics Test Performance

    Science.gov (United States)

    Phillips, David S.; Hannon, James C.; Castelli, Darla M.

    2015-01-01

    The effect of an acute bout of physical activity on academic performance in school-based settings is under researched. The purpose of this study was to examine associations between a single, vigorous (70-85%) bout of physical activity completed during physical education on standardized mathematics test performance among 72, eighth grade students…

  3. Towards Smart Buildings Performance Testing as a Service

    DEFF Research Database (Denmark)

    Markoska, Elena; Lazarova-Molnar, Sanja

    2018-01-01

    Energy consumption in buildings accounts for ca. 40% of the world’s total energy consumption, yielding a call for attention to their performance and improvement of their behavior. The concept of performance testing has been developed as an approach to control, potentially lower, and bring awarene...

  4. Motivation and performance in physical education: an experimental test.

    Science.gov (United States)

    Moreno, Juan A; González-Cutre, David; Martín-Albo, José; Cervelló, Eduardo

    2010-01-01

    The purpose of this study was to analyse, experimentally, the relationships between motivation and performance in a lateral movement test in physical education. The study group consisted of 363 students (227 boys and 136 girls), aged between 12 and 16, who were randomly divided into three groups: an experimental group in which an incremental ability belief was induced, another experimental group in which an entity ability belief was induced, and a control group where there was no intervention. Measurements were made of situational intrinsic motivation, perceived competence in executing the task and performance. The results revealed that the incremental group reported higher scores on the situational intrinsic motivation scale. The entity group demonstrated better performance in the first test attempt than the incremental group but, in the second attempt, the performance was similar in the different groups. Perhaps the initial differences in performance disappeared because the incremental group counted on improving in the second attempt. These results are discussed in relation to the intensity with which the teacher conveys information relating to incremental ability belief of the pupil to increase intrinsic motivation and performance. Key pointsThe incremental group showed more situational intrinsic motivation.The entity group showed higher performance in the first test attempt, but significant differences disappeared in the second attempt.It seems that this incremental belief and greater intrinsic motivation made the students trust they would improve their performance in the second attempt at the lateral movement test.

  5. The diagnostic odds ratio: a single indicator of test performance

    NARCIS (Netherlands)

    Glas, Afina S.; Lijmer, Jeroen G.; Prins, Martin H.; Bonsel, Gouke J.; Bossuyt, Patrick M. M.

    2003-01-01

    Diagnostic testing can be used to discriminate subjects with a target disorder from subjects without it. Several indicators of diagnostic performance have been proposed, such as sensitivity and specificity. Using paired indicators can be a disadvantage in comparing the performance of competing

  6. Performance test of a dual-purpose disc agrochemical applicator ...

    African Journals Online (AJOL)

    The performance test of a dual-purpose disc agrochemical applicator for field crop was conducted with view to assess the distribution patterns/droplet sizes and uniformity of spreading and or spraying for the agrochemical application. The equipment performances for both granular and liquid chemical application were ...

  7. [Performance of normal young adults in two temporal resolution tests].

    Science.gov (United States)

    Zaidan, Elena; Garcia, Adriana Pontin; Tedesco, Maria Lucy Fraga; Baran, Jane A

    2008-01-01

    temporal auditory processing is defined as the perception of sound or of sound alteration within a restricted time interval and is considered a fundamental ability for the auditory perception of verbal and non verbal sounds, for the perception of music, rhythm, periodicity and in the discrimination of pitch, duration and of phonemes. to compare the performance of normal Brazilian adults in two temporal resolution tests: the Gaps-in-Noise Test (GIN) and the Random Gap Detection Test (RGDT), and to analyze potential differences of performance in these two tests. twenty-five college students with normal hearing (11 males and 14 females) and no history of educational, neurological and/or language problems, underwent the GIN and RGDT at 40dB SL. statistically significant gender effects for both tests were found, with female participants showing poorer performance on both temporal processing tests. In addition, a comparative analysis of the results obtained in the GIN and RGDT revealed significant differences in the threshold measures derived for these two tests. In general, significantly better gap detection thresholds were observed for both male and female participants on the GIN test when compared to the results obtained for the RGDT. male participants presented better performances on both RGDT and GIN, when compared to the females. There were no differences in performance between right and left ears on the GIN test. Participants of the present investigation, males and females, performed better on the GIN when compared to the RGDT. The GIN presented advantages over the RGDT, not only in terms of clinical validity and sensibility, but also in terms of application and scoring.

  8. Team performance and collective efficacy in the dynamic psychology of competitive team: a Bayesian network analysis.

    Science.gov (United States)

    Fuster-Parra, P; García-Mas, A; Ponseti, F J; Leo, F M

    2015-04-01

    The purpose of this paper was to discover the relationships among 22 relevant psychological features in semi-professional football players in order to study team's performance and collective efficacy via a Bayesian network (BN). The paper includes optimization of team's performance and collective efficacy using intercausal reasoning pattern which constitutes a very common pattern in human reasoning. The BN is used to make inferences regarding our problem, and therefore we obtain some conclusions; among them: maximizing the team's performance causes a decrease in collective efficacy and when team's performance achieves the minimum value it causes an increase in moderate/high values of collective efficacy. Similarly, we may reason optimizing team collective efficacy instead. It also allows us to determine the features that have the strongest influence on performance and which on collective efficacy. From the BN two different coaching styles were differentiated taking into account the local Markov property: training leadership and autocratic leadership. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Fuel properties and engine performance of biodiesel from waste cooking oil collected in Dhaka city

    Science.gov (United States)

    Islam, R. B.; Islam, R.; Uddin, M. N.; Ehsan, Md.

    2016-07-01

    Waste cooking oil can be a potential source of biodiesel that has least effect on the edible oil consumption. Increasing number of hotel-restaurants and more active monitoring by health authorities have increased the generation of waste cooking oil significantly in densely populated cities like Dhaka. If not used or disposed properly, waste cooking oil itself may generate lot of environmental issues. In this work, waste cooking oils from different restaurants within Dhaka City were collected and some relevant properties of these waste oils were measured. Based on the samples studied one with the highest potential as biodiesel feed was identified and processed for engine performance. Standard trans-esterification process was used to produce biodiesel from the selected waste cooking oil. Biodiesel blends of B20 and B40 category were made and tested on a single cylinder direct injection diesel engine. Engine performance parameters included - bhp, bsfc and exhaust emission for rated and part load conditions. Results give a quantitative assessment of the potential of using biodiesel from waste cooking oil as fuel for diesel engines in Bangladesh.

  10. Motivational deficits and cognitive test performance in schizophrenia.

    Science.gov (United States)

    Fervaha, Gagan; Zakzanis, Konstantine K; Foussias, George; Graff-Guerrero, Ariel; Agid, Ofer; Remington, Gary

    2014-09-01

    Motivational and cognitive deficits are core features of schizophrenia, both closely linked with functional outcomes. Although poor effort and decreased motivation are known to affect performance on cognitive tests, the extent of this relationship is unclear in patients with schizophrenia. To evaluate the association between intrinsic motivation and cognitive test performance in patients with schizophrenia. Cross-sectional and 6-month prospective follow-up study performed at 57 sites in the United States, including academic and community medical treatment centers, participating in the Clinical Antipsychotic Trials of Intervention Effectiveness study. The primary sample included 431 stable patients with a DSM-IV diagnosis of schizophrenia currently receiving a stable medication regimen. Cognitive performance and intrinsic motivation were evaluated using a comprehensive neuropsychological test battery and a derived measure from the Heinrichs-Carpenter Quality of Life Scale, respectively. Symptom severity and functional status were also assessed. The primary outcome variable was global neurocognition. Individual domains of cognition were also evaluated for their association with motivation. Level of intrinsic motivation was significantly and positively correlated with global cognitive test performance, a relationship that held for each domain of cognition evaluated (correlation range, 0.20-0.34; P motivation and cognitive performance also remained significant after controlling for antipsychotic dose (P motivation during the 6-month follow-up was also found to be significantly related to improvement in global cognitive performance (P motivation and cognitive performance and suggest that test performance is not purely a measure of ability. Future studies assessing cognition in patients with schizophrenia should consider potential moderating variables such as effort and motivation. Implications for the assessment and interpretation of cognitive impairment based on

  11. Report on long range alpha detector (LRAD) performance tests

    International Nuclear Information System (INIS)

    Kobayashi, Hirohide; Unno, Motoyoshi; Ishikawa, Hisashi; Yoshida, Tadayoshi

    2002-10-01

    At present, alpha contamination measurement on objects is conducted with ZnS scintillation survey meter (direct method) and smear test (indirect method). But it is difficult to measure large and complicated objects by direct method. Long Range Alpha Detector (LRAD) was produced as a solution for this problem. We carried out performance tests of this LRAD. As a result of the performance tests, we confirmed the linear relation between the measurement values of LRAD and alpha-radioactivity on the surface of objects. (author)

  12. The Functional Task Test (FTT): An Interdisciplinary Testing Protocol to Investigate the Factors Underlying Changes in Astronaut Functional Performance

    Science.gov (United States)

    Bloomberg, J. J.; Lawrence, E. L.; Arzeno, N. M.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts. S. H.; hide

    2011-01-01

    Exposure to space flight causes adaptations in multiple physiological systems including changes in sensorimotor, cardiovascular, and neuromuscular systems. These changes may affect a crewmember s ability to perform critical mission tasks immediately after landing on a planetary surface. The overall goal of this project is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. To achieve this goal we developed an interdisciplinary testing protocol (Functional Task Test, FTT) that evaluates both astronaut functional performance and related physiological changes. Functional tests include ladder climbing, hatch opening, jump down, manual manipulation of objects and tool use, seat egress and obstacle avoidance, recovery from a fall and object translation tasks. Physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper- and lower-body muscle strength, power, endurance, control, and neuromuscular drive. Crewmembers perform this integrated test protocol before and after short (Shuttle) and long-duration (ISS) space flight. Data are collected on two sessions before flight, on landing day (Shuttle only) and 1, 6 and 30 days after landing. Preliminary results from both Shuttle and ISS crewmembers indicate decrement in performance of the functional tasks after both short and long-duration space flight. On-going data collection continues to improve the statistical power required to map changes in functional task performance to alterations in physiological systems. The information obtained from this study will be used to design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight.

  13. Testing Game-Based Performance in Team-Handball.

    Science.gov (United States)

    Wagner, Herbert; Orwat, Matthias; Hinz, Matthias; Pfusterschmied, Jürgen; Bacharach, David W; von Duvillard, Serge P; Müller, Erich

    2016-10-01

    Wagner, H, Orwat, M, Hinz, M, Pfusterschmied, J, Bacharach, DW, von Duvillard, SP, and Müller, E. Testing game-based performance in team-handball. J Strength Cond Res 30(10): 2794-2801, 2016-Team-handball is a fast paced game of defensive and offensive action that includes specific movements of jumping, passing, throwing, checking, and screening. To date and to the best of our knowledge, a game-based performance test (GBPT) for team-handball does not exist. Therefore, the aim of this study was to develop and validate such a test. Seventeen experienced team-handball players performed 2 GBPTs separated by 7 days between each test, an incremental treadmill running test, and a team-handball test game (TG) (2 × 20 minutes). Peak oxygen uptake (V[Combining Dot Above]O2peak), blood lactate concentration (BLC), heart rate (HR), sprinting time, time of offensive and defensive actions as well as running intensities, ball velocity, and jump height were measured in the game-based test. Reliability of the tests was calculated using an intraclass correlation coefficient (ICC). Additionally, we measured V[Combining Dot Above]O2peak in the incremental treadmill running test and BLC, HR, and running intensities in the team-handball TG to determine the validity of the GBPT. For the test-retest reliability, we found an ICC >0.70 for the peak BLC and HR, mean offense and defense time, as well as ball velocity that yielded an ICC >0.90 for the V[Combining Dot Above]O2peak in the GBPT. Percent walking and standing constituted 73% of total time. Moderate (18%) and high (9%) intensity running in the GBPT was similar to the team-handball TG. Our results indicated that the GBPT is a valid and reliable test to analyze team-handball performance (physiological and biomechanical variables) under conditions similar to competition.

  14. Combinatoric Models of Information Retrieval Ranking Methods and Performance Measures for Weakly-Ordered Document Collections

    Science.gov (United States)

    Church, Lewis

    2010-01-01

    This dissertation answers three research questions: (1) What are the characteristics of a combinatoric measure, based on the Average Search Length (ASL), that performs the same as a probabilistic version of the ASL?; (2) Does the combinatoric ASL measure produce the same performance result as the one that is obtained by ranking a collection of…

  15. 78 FR 41926 - Proposed Information Collection Request; Comment Request; Performance Evaluation Studies on...

    Science.gov (United States)

    2013-07-12

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OECA-2013-0413; FRL--9832-8] Proposed Information Collection Request; Comment Request; Performance Evaluation Studies on Wastewater Laboratories (Renewal); EPA... request (ICR), ``Performance Evaluation Studies on Wastewater Laboratories'' (EPA ICR No. 0234.11, OMB...

  16. High-precision performance testing of the LHC power converters

    CERN Document Server

    Bastos, M; Dreesen, P; Fernqvist, G; Fournier, O; Hudson, G

    2007-01-01

    The magnet power converters for LHC were procured in three parts, power part, current transducers and control electronics, to enable a maximum of industrial participation in the manufacturing and still guarantee the very high precision (a few parts in 10-6) required by LHC. One consequence of this approach was several stages of system tests: factory reception tests, CERN reception tests, integration tests , short-circuit tests and commissioning on the final load in the LHC tunnel. The majority of the power converters for LHC have now been delivered, integrated into complete converter and high-precision performance testing is well advanced. This paper presents the techniques used for high-precision testing and the results obtained.

  17. Pavement Subgrade Performance Study in the Danish Road Testing Machine

    DEFF Research Database (Denmark)

    Ullidtz, Per; Ertman Larsen, Hans Jørgen

    1997-01-01

    Most existing pavement subgrade criteria are based on the AASHO Road Test, where only one material was tested and for only one climatic condition. To study the validity of these criteria and to refine the criteria a co-operative research program entitled the "International Pavement Subgrade...... Performance Study" was sponsored by the FHWA with American, Finnish and Danish partners. This paper describes the first test series which was carried out in the Danish Road Testing Machine (RTM).The first step in this program is a full scale test on an instrumented pavement in the Danish Road Testing Machine....... Pressure gauges and strain cells were installed in the upper part of the subgrade, for measuring stresses and strains in all three directions. During and after construction FWD testing was carried out to evaluate the elastic parameters of the materials. These parameters were then used with the theory...

  18. Correlation Between Screening Mammography Interpretive Performance on a Test Set and Performance in Clinical Practice.

    Science.gov (United States)

    Miglioretti, Diana L; Ichikawa, Laura; Smith, Robert A; Buist, Diana S M; Carney, Patricia A; Geller, Berta; Monsees, Barbara; Onega, Tracy; Rosenberg, Robert; Sickles, Edward A; Yankaskas, Bonnie C; Kerlikowske, Karla

    2017-10-01

    Evidence is inconsistent about whether radiologists' interpretive performance on a screening mammography test set reflects their performance in clinical practice. This study aimed to estimate the correlation between test set and clinical performance and determine if the correlation is influenced by cancer prevalence or lesion difficulty in the test set. This institutional review board-approved study randomized 83 radiologists from six Breast Cancer Surveillance Consortium registries to assess one of four test sets of 109 screening mammograms each; 48 radiologists completed a fifth test set of 110 mammograms 2 years later. Test sets differed in number of cancer cases and difficulty of lesion detection. Test set sensitivity and specificity were estimated using woman-level and breast-level recall with cancer status and expert opinion as gold standards. Clinical performance was estimated using women-level recall with cancer status as the gold standard. Spearman rank correlations between test set and clinical performance with 95% confidence intervals (CI) were estimated. For test sets with fewer cancers (N = 15) that were more difficult to detect, correlations were weak to moderate for sensitivity (woman level = 0.46, 95% CI = 0.16, 0.69; breast level = 0.35, 95% CI = 0.03, 0.61) and weak for specificity (0.24, 95% CI = 0.01, 0.45) relative to expert recall. Correlations for test sets with more cancers (N = 30) were close to 0 and not statistically significant. Correlations between screening performance on a test set and performance in clinical practice are not strong. Test set performance more accurately reflects performance in clinical practice if cancer prevalence is low and lesions are challenging to detect. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  19. Pharmacists performing quality spirometry testing: an evidence based review.

    Science.gov (United States)

    Cawley, Michael J; Warning, William J

    2015-10-01

    The scope of pharmacist services for patients with pulmonary disease has primarily focused on drug related outcomes; however pharmacists have the ability to broaden the scope of clinical services by performing diagnostic testing including quality spirometry testing. Studies have demonstrated that pharmacists can perform quality spirometry testing based upon international guidelines. The primary aim of this review was to assess the published evidence of pharmacists performing quality spirometry testing based upon American Thoracic Society/European Respiratory Society (ATS/ERS) guidelines. In order to accomplish this, the description of evidence and type of outcome from these services were reviewed. A literature search was conducted using five databases [PubMed (1946-January 2015), International Pharmaceutical Abstracts (1970 to January 2015), Cumulative Index of Nursing and Allied Health Literature, Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews] with search terms including pharmacy, spirometry, pulmonary function, asthma or COPD was conducted. Searches were limited to publications in English and reported in humans. In addition, Uniform Resource Locators and Google Scholar searches were implemented to include any additional supplemental information. Eight studies (six prospective multi-center trials, two retrospective single center studies) were included. Pharmacists in all studies received specialized training in performing spirometry testing. Of the eight studies meeting inclusion and exclusion criteria, 8 (100%) demonstrated acceptable repeatability of spirometry testing based upon standards set by the ATS/ERS guidelines. Acceptable repeatability of seven studies ranged from 70 to 99% consistent with published data. Available evidence suggests that quality spirometry testing can be performed by pharmacists. More prospective studies are needed to add to the current evidence of quality spirometry testing performed by

  20. Performance demonstration experience for reactor pressure vessel shell ultrasonic testing

    International Nuclear Information System (INIS)

    Zado, V.

    1998-01-01

    The most ultrasonic testing techniques used by many vendors for pressurized water reactor (PWR) examinations were based on American Society of Mechanical Engineers 'Boiler and Pressurized Vessel Code' (ASME B and PV Code) Sections XI and V. The Addenda of ASME B and PV Code Section XI, Edition 1989 introduced Appendix VIII - 'Performance Demonstration for Ultrasonic Examination Systems'. In an effort to increase confidence in performance of ultrasonic testing of the operating nuclear power plants in United States, the ultrasonic testing performance demonstration examination of reactor vessel welds is performed in accordance with Performance Demonstration Initiative (PDI) program which is based on ASME Code Section XI, Appendix VIII requirements. This article provides information regarding extensive qualification preparation works performed prior EPRI guided performance demonstration exam of reactor vessel shell welds accomplished in January 1997 for the scope of Appendix VIII, Supplements IV and VI. Additionally, an overview of the procedures based on requirements of ASME Code Section XI and V in comparison to procedure prepared for Appendix VIII examination is given and discussed. The samples of ultrasonic signals obtained from artificial flaws implanted in vessel material are presented and results of ultrasonic testing are compared to actual flaw sizes. (author)

  1. STOCK MARKET AND TAX REVENUE COLLECTION IN MALAYSIA: EVIDENCE FROM COINTEGRATION AND CAUSALITY TESTS

    OpenAIRE

    Roshaiza Taha

    2013-01-01

    This study empirically examined the relationship between stock market performance and taxation in Malaysia over the period 1980 to 2008. The Gregory Hansen methodology was utilized to examine which tax collected by Malaysia’s Government most impacted stock market performance in Malaysia. The results show that stock market performance contributes most to the changes in company tax revenue as compared to personal taxes and real property gain taxes. In addition, the analysis detects a signific...

  2. Double-shell tank integrity assessments ultrasonic test equipment performance test

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, D.C.

    1996-09-26

    A double-shell tank (DST) inspection (DSTI) system was performance tested over three months until August 1995 at Pittsburgh, Pennsylvania, completing a contract initiated in February 1993 to design, fabricate, and test an ultrasonic inspection system intended to provide ultrasonic test (UT) and visual data to determine the integrity of 28 DSTs at Hanford. The DSTs are approximately one-million-gallon underground radioactive-waste storage tanks. The test was performed in accordance with a procedure (Jensen 1995) that included requirements described in the contract specification (Pfluger 1995). This report documents the results of tests conducted to evaluate the performance of the DSTI system against the requirements of the contract specification. The test of the DSTI system also reflects the performance of qualified personnel and operating procedures.

  3. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Kelly, C. Edward; Klee, Paul M.

    1997-01-01

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted

  4. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Kelly, C.E.; Klee, P.M.

    1997-01-01

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted. copyright 1997 American Institute of Physics

  5. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Dombeck, T.; Gannon, J.; Kraushaar, P.; McInturff, A.; Savord, T.; Tool, G.

    1993-05-01

    The string test facility was constructed to provide a development test bed for the arc regions of the Superconducting Super Collider (SSC). Significant effort has been devoted to the development and testing of superconducting magnets, spools, and accelerator control systems required for the SSC. The string test facility provides the necessary environment required to evaluate the operational performance of these components as they are configured as an accelerator lens in the collider. This discussion will review the results of high current testing of the string conducted to evaluate magnet element uniformity and compatibility, the splice resistance used to connect the magnets, and system response to various quench conditions. Performance results of the spools, energy bypass systems, energy dump, and the power supply system are also discussed

  6. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Dombeck, T.; Gannon, J.; Kraushaar, P.; McInturff, A.; Savord, T.; Tool, G.

    1993-01-01

    The string test facility was constructed to provide a development test bed for the arc regions of the Superconducting Super Collider (SSC). Significant effort has been devoted to the development and testing of superconducting magnets, spools, and accelerator control systems required for the SSC. The string test facility provides the necessary environment required to evaluate the operational performance of these components as they are configured as an accelerator lens in the collider. This discussion will review the results of high current testing of the string conducted to evaluate magnet element uniformity and compatibility, the splice resistance used to connect the magnets, and system response to various quench conditions. Performance results of the spools, energy bypass systems, energy dump, and the power supply system are also discussed

  7. Performance and durability testing of parabolic trough receivers

    Science.gov (United States)

    Lei, Dongqiang; Fu, Xuqiang; Zhao, Dongming; Yuan, Guofeng; Wang, Zhifeng; Guo, Minghuan

    2017-06-01

    The paper describes the key performance and durability testing facilities of the parabolic trough receiver developed by Institute of Electrical Engineering, Chinese Academy of Sciences. The indoor heat loss test can be applied at 4-7 different temperature levels within 200-550 on receivers. The optical efficiency test bench consists of 12 metal halide lamps as the solar simulator and a 5 m length half-elliptical cylinder reflector with flat end reflectors. 3 ultra-precision temperature sensors are used in receiver each end to get the temperature difference. The residual gas analysis test bench is applied to analyze and predict the vacuum lifetime of the receiver. It can test the variations of composition and partial pressure of residual gases with temperature and time in the receiver annulus space by a high sensitivity quadrupole mass spectrometer gas analyzer. A coating accelerated ageing test bench, which is also used to test the thermal cycle, has been developed. This test bench uses the absorber tube of the recevier as the resistance heater to heat up the whole receiver. The coating lifetime can be predicted by the Arrhenius parameters. For the cycling test, the compressed air is used to directly cool the inner surface of the absorber tube. The thermal cycling test is performed with temperature cycles from 150 °C to 450 °C for 160 cycles. The maximum thermal cycling frequency is 8 cycles per day. The mechanical fatigue test bench is used to test the bellows and the glass-to-metal seals durability at the same time. Both bellows are expanded and compressed to 6.5 mm in turn with 10,000 cycles. A new rotating test bench was also developed to test the thermal efficiency of the receiver.

  8. Technical report: serial collections of placentomes during parturition in cattle and subsequent reproductive performance.

    Science.gov (United States)

    McNeel, Anthony K; Ondrak, Jeff D; Cushman, Robert A

    2013-05-01

    Placental separation is a complex physiological event in reproductive physiology and the underlying molecular mechanisms remain unclear. When comparing different experiments the timing of tissue collections is a significant consideration due to the variability in time between fetal expulsion and expulsion of the placenta (30 min to >24 h). This makes comparison of tissues samples across animals difficult and supports the need for serial tissue collections within animal. Additionally, the instrument most commonly used, a modified Richter-Resinsinger effeminator, for placentome collections is difficult to obtain and there are no data in the literature record regarding subsequent reproductive performance of animals subjected placentome collections. To facilitate continued research into the physiology behind placental separation, we designed an instrument from readily available components and performed serial transvaginal placentome collections in cattle. Three placentomes at 2-h intervals were collected after expulsion of the calf in 18 multiparous cows. There was no incidence of mortality and all cows resumed estrous after the procedure. Neither time from placentome collection nor age had a significant effect on pregnancy status at diagnosis (P > 0.05). These results demonstrate the viability of and utility of this device for collecting multiple placentomes in cattle.

  9. Dynamic Performance Characteristic Tests of Real Scale Lead Rubber Bearing for the Evaluation of Performance Criteria

    International Nuclear Information System (INIS)

    Kim, Min Kyu; Kim, Jung-Han; Choi, In-Kil

    2014-01-01

    Dynamic characteristic tests of full scale lead rubber bearing were performed for the evaluation of performance criteria of isolation system for nuclear power plants. For the dynamic test for a full scale rubber bearing, two 1500mm diameter lead rubber bearings were manufactured. The viewpoints of this dynamic test are determination of an ultimate shear strain level of lead rubber bearing, behavior of rubber bearing according to static and dynamic input motion, sinusoidal and random (earthquake) motion, and 1-dimentional and 2-dimensional input motion. In this study, seismic isolation device tests were performed for the evaluation of performance criteria of isolation system. Through this test, it can be recognized that in the case of considering a mechanical property test, dynamic and multi degree of loading conditions should be determined. But these differences should be examined how much affect to the global structural behavior

  10. A systematic review of the cost of data collection for performance monitoring in hospitals.

    Science.gov (United States)

    Jones, Cheryl; Gannon, Brenda; Wakai, Abel; O'Sullivan, Ronan

    2015-04-01

    Key performance indicators (KPIs) are used to identify where organisational performance is meeting desired standards and where performance requires improvement. Valid and reliable KPIs depend on the availability of high-quality data, specifically the relevant minimum data set ((MDS) the core data identified as the minimum required to measure performance for a KPI) elements. However, the feasibility of collecting the relevant MDS elements is always a limitation of performance monitoring using KPIs. Preferably, data should be integrated into service delivery, and, where additional data are required that are not currently collected as part of routine service delivery, there should be an economic evaluation to determine the cost of data collection. The aim of this systematic review was to synthesise the evidence base concerning the costs of data collection in hospitals for performance monitoring using KPI, and to identify hospital data collection systems that have proven to be cost minimising. We searched MEDLINE (1946 to May week 4 2014), Embase (1974 to May week 2 2014), and CINAHL (1937 to date). The database searches were supplemented by searching for grey literature through the OpenGrey database. Data was extracted, tabulated, and summarised as part of a narrative synthesis. The searches yielded a total of 1,135 publications. After assessing each identified study against specific inclusion exclusion criteria only eight studies were deemed as relevant for this review. The studies attempt to evaluate different types of data collection interventions including the installation of information communication technology (ICT), improvements to current ICT systems, and how different analysis techniques may be used to monitor performance. The evaluation methods used to measure the costs and benefits of data collection interventions are inconsistent across the identified literature. Overall, the results weakly indicate that collection of hospital data and improvements in data

  11. Play for Performance: Using Computer Games to Improve Motivation and Test-Taking Performance

    Science.gov (United States)

    Dennis, Alan R.; Bhagwatwar, Akshay; Minas, Randall K.

    2013-01-01

    The importance of testing, especially certification and high-stakes testing, has increased substantially over the past decade. Building on the "serious gaming" literature and the psychology "priming" literature, we developed a computer game designed to improve test-taking performance using psychological priming. The game primed…

  12. History of personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, C. G.

    2007-01-01

    The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11 (2001). Now in its third edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by US Nuclear Regulatory Commission (NRC) regulations. The US Dept. of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Dept. of Energy Laboratory Accreditation Program (DOELAP). A focus in recent years has been the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonisation to US personal dosemeter processing testing. Since there is no type testing program in the US for personal dosemeters, the testing philosophy of ANSI N13.11 has always combined elements of type testing and routine performance testing. This philosophy is explored in detail in this presentation, along with trends in the development of the document to its present state. In addition, a look will be taken at what the future holds for the next revision of the document, scheduled to begin in 2005. (authors)

  13. Personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, C.G.

    2005-01-01

    Full text: The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11 (2002). Now in its third edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by US Nuclear Regulatory Commission (NRC) regulations. The US Department of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Department of Energy Laboratory Accreditation Program (DOELAP). A focus in recent years has been the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonization to US personal dosimeter processing testing. The testing philosophy of ANSI N13.11 has always combined elements of type testing and routine performance testing and is thus different from the testing philosophy used in the rest of the world. This unique philosophy is explored in detail in this presentation, along with trends in the development of the document to its present state. In addition, a look will be taken at what the future holds for the next revision of the document, scheduled to begin in 2005. (author)

  14. Top management turnover and organizational performance: A test of a contingency model

    OpenAIRE

    Boyne, George A.; James, Oliver; John, Peter; Petrovsky, Nicolai

    2011-01-01

    A crucial test of whether "management matters" is whether changes in the team at the top of an organization make a difference. Focusing on turnover in the collective senior team rather than successions of individual chief executives, this article argues that the impact of leadership succession is contingent upon prior organizational performance. The evidence on English local government shows that changes in the top management team lead to improvements when initial performance is bad, but resu...

  15. Fast Flux Test Facility core restraint system performance

    International Nuclear Information System (INIS)

    Hecht, S.L.; Trenchard, R.G.

    1990-02-01

    Characterizing Fast Flux Test Facility (FFTF) core restraint system performance has been ongoing since the first operating cycle. Characterization consists of prerun analysis for each core load, in-reactor and postirradiation measurements of subassembly withdrawal loads and deformations, and using measurement data to fine tune predictive models. Monitoring FFTF operations and performing trend analysis has made it possible to gain insight into core restraint system performance and head off refueling difficulties while maximizing component lifetimes. Additionally, valuable information for improved designs and operating methods has been obtained. Focus is on past operating experience, emphasizing performance improvements and avoidance of potential problems. 4 refs., 12 figs., 2 tabs

  16. A novel simulation method to evaluate the collection performance of a monolithic active pixel sensor

    International Nuclear Information System (INIS)

    Fu Min; Tang Zhen'an

    2011-01-01

    A novel simulation method is presented in this paper to evaluate the collection performance of monolithic active pixel sensor (MAPS) devices for minimum ionizing particle tracking. A simplified 3D matrix pixel structure is built using the computer aided design software Sentaurus. The virtual device is then divided into hundreds of parts and an independent customized X photon model is involved in each part to simulate the conditions under 55 Fe radiation. After data processing and analysis, charge collection efficiency, collection time and diffusion conditions can be estimated in detail. In order to verify the reliability of the method, comparisons are made between the simulations and experiments. Although there are some defects, it can be concluded that the proposed idea is a feasible method for the evaluation of the MAPS collection performance. (authors)

  17. Exploring Data Collection Innovations by Examining the Effects of Relationship Marketing on Performance in Times of Crisis

    Directory of Open Access Journals (Sweden)

    Armando Luís Vieira

    2014-05-01

    Full Text Available The scientific quality, rigour, and impact of a considerable number, if not the vast majority, of marketing studies depend on an effective data collection process. Most of the researchers in these and related areas rely on traditional data collection tools, such as face-to-face, pen-andpaper, or online questionnaires, which are not very effective, both in terms of the time and money required to gather a reasonable number of observations. Bearing in mind that crises should also be an opportunity for researchers and institutions to develop more productive and effective research tools and procedures, the aim of this research is twofold: 1 to test a model that relates relationship marketing (RM efforts with performance; and 2 to explore innovative, more effective, data collection tools to be employed in a marketing research context. To this end, this study proposes and tests a model of the effects of RM antecedents and mediators on objective performance. The empirical work draws on the perceptions of 4,389 firm representatives in terms of their relationships with their counterparts in hotels, collected by using AppGeneration Npolls . Structural equation modelling results suggest that commitment is the strongest determinant of share of business, and fully mediates the impact of relationship quality (with satisfaction and trust as first-order dimensions on objective performance. From an innovative, methodological perspective, this study demonstrates that it is possible to collect a significantly high number of observations in a very short period of time, with considerable advantages when compared to traditional data collection procedures.

  18. Differences in gender performance on competitive physics selection tests

    OpenAIRE

    Kate Wilson; David Low; Matthew Verdon; Alix Verdon

    2016-01-01

    [This paper is part of the Focused Collection on Gender in Physics.] We have investigated gender differences in performance over the past eight years on the Australian Science Olympiad Exam (ASOE) for physics, which is taken by nearly 1000 high school students each year. The ASOE, run by Australian Science Innovations (ASI), is the initial stage of the process of selection of teams to represent Australia at the Asian and International Physics Olympiads. Students taking the exam are generally ...

  19. Measurement properties of continuous text reading performance tests.

    Science.gov (United States)

    Brussee, Tamara; van Nispen, Ruth M A; van Rens, Ger H M B

    2014-11-01

    Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. A literature search was performed in PubMed, Embase and PsycInfo. Subsequently, information on design and content of reading tests, study design and measurement properties were extracted using consensus-based standards for selection of health measurement instruments. Quality of studies, reading tests and measurement properties were systematically assessed using pre-specified criteria. From 2334 identified articles, 20 relevant articles were found on measurement properties of three reading tests in various languages: IReST, MNread Reading Test and Radner Reading Charts. All three reading tests scored high on content validity. Reproducibility studies (repeated measurements between different testing sessions) of the IReST and MNread of commercially available reading tests in different languages were missing. The IReST scored best on inter-language comparison, the MNread scored well in repeatability studies (repeated measurements under the same conditions) and the Radner showed good reproducibility in studies. Although in daily practice there are other continuous text reading tests available meeting the criteria of this review, measurement properties were described in scientific studies for only three of them. Of the few available studies, the quality and content of study design and methodology used varied. For testing existing reading tests and the development of new ones, for example in other languages, we make several recommendations, including careful description of patient characteristics, use of objective and subjective lighting levels, good control of working distance, documentation of the number of raters and their training, careful documentation of scoring rules and the use of Bland-Altman analyses or similar for

  20. Fracture testing and performance of beryllium copper alloy C17510

    International Nuclear Information System (INIS)

    Murray, H.A.; Zatz, I.J.

    1994-05-01

    When a literature search and discussion with manufacturers revealed that there was virtually no existing data related to the fracture properties and behavior of copper beryllium alloy C17510, a series of test programs was undertaken to ascertain this information for several variations in material processing and chemistry. These variations in C17510 were primarily optimized for combinations of strength and conductivity. While originally intended for use as cyclically loaded high-field, high-strength conductors in fusion energy research, material testing of C17510 has indicated that it is an attractive and economical alternative for a host of other structural, mechanical and electrical applications. ASTM tests performed on three variations of C17510 alloys included both J-integral and plane strain fracture toughness testing and fatigue crack growth rate tests, as well as verifying tensile, hardness, Charpy, and other well defined mechanical properties. Fracture testing was performed at both room and liquid nitrogen temperatures, which bound the thermal environment anticipated for the fusion components being designed. Fatigue crack propagation stress ratios ranged from nominal zero to minus one at each temperature. In order to confirm the test results, duplicate and independent test programs were awarded to separate facilities with appropriate test experience, whenever possible. The primary goal of the test program, to determine and bound the fracture toughness and Paris constants for C17510,was accomplished. In addition, a wealth of information was accumulated pertaining to crack growth characteristics, effects of directionality and potential testing pitfalls. The paper discusses the test program and its findings in detail

  1. Gamma-ray shielding design and performance test of WASTEF

    International Nuclear Information System (INIS)

    Matsumoto, Seiichiro; Aoyama, Saburo; Tashiro, Shingo; Nagai, Shiro

    1984-06-01

    The Waste Safety Testing Facility (WASTEF) was planned in 1978 to test the safety performance of HLW vitrified forms under the simulated conditions of long term storage and disposal, and completed in August 1981. The designed feature of the facility is to treat the vitrified forms contain actual high-level wastes of 5 x 10 4 Ci in maximum with 5 units of concrete shilded hot cells (3 units : Bate-Gamma cells, 2 units : Alpha-Gamma cells) and one units of Alpha-Gamma lead shielded cell, and to store radioactivity of 10 6 Ci in maximum. The safety performance of this facility is fundamentally maintained with confinement of radioactivity and shielding of the radiation. This report describes the method of gamma-ray shielding design, evaluation of the shielding test performed by using sealded gamma-ray sources(Co-60). (author)

  2. Acting in solidarity: Testing an extended dual pathway model of collective action by bystander group members.

    Science.gov (United States)

    Saab, Rim; Tausch, Nicole; Spears, Russell; Cheung, Wing-Yee

    2015-09-01

    We examined predictors of collective action among bystander group members in solidarity with a disadvantaged group by extending the dual pathway model of collective action, which proposes one efficacy-based and one emotion-based path to collective action (Van Zomeren, Spears, Fischer, & Leach, 2004). Based on two proposed functions of social identity performance (Klein, Spears, & Reicher, 2007), we distinguished between the efficacy of collective action at consolidating the identity of a protest movement and its efficacy at achieving social change (political efficacy). We expected identity consolidation efficacy to positively predict collective action tendencies directly and indirectly via political efficacy. We also expected collective action tendencies to be positively predicted by moral outrage and by sympathy in response to disadvantaged outgroup's suffering. These hypotheses were supported in two surveys examining intentions to protest for Palestine in Britain (Study 1), and intentions to attend the June 4th vigil in Hong Kong to commemorate the Tiananmen massacre among a sample of Hong Kong citizens (Study 2). The contributions of these findings to research on the dual pathway model of collective action and the different functions of collective action are discussed. © 2014 The British Psychological Society.

  3. Light water reactor pressure isolation valve performance testing

    International Nuclear Information System (INIS)

    Neely, H.H.; Jeanmougin, N.M.; Corugedo, J.J.

    1990-07-01

    The Light Water Reactor Valve Performance Testing Program was initiated by the NRC to evaluate leakage as an indication of valve condition, provide input to Section XI of the ASME Code, evaluate emission monitoring for condition and degradation and in-service inspection techniques. Six typical check and gate valves were purchased for testing at typical plant conditions (550F at 2250 psig) for an assumed number of cycles for a 40-year plant lifetime. Tests revealed that there were variances between the test results and the present statement of the Code; however, the testing was not conclusive. The life cycle tests showed that high tech acoustic emission can be utilized to trend small leaks, that specific motor signature measurement on gate valves can trend and indicate potential failure, and that in-service inspection techniques for check valves was shown to be both feasible and an excellent preventive maintenance indicator. Life cycle testing performed here did not cause large valve leakage typical of some plant operation. Other testing is required to fully understand the implication of these results and the required program to fully implement them. (author)

  4. Radioactive material package test standards and performance requirements - public perception

    International Nuclear Information System (INIS)

    Pope, R.B.; Shappert, L.B.; Rawl, R.R.

    1992-01-01

    This paper addresses issues related to the public perception of the regulatory test standards and performance requirements for packaging and transporting radioactive material. Specifically, it addresses the adequacy of the package performance standards and testing for Type B packages, which are those packages designed for transporting the most hazardous quantities and forms of radioactive material. Type B packages are designed to withstand accident conditions in transport. To improve public perception, the public needs to better understand: (a) the regulatory standards and requirements themselves, (b) the extensive history underlying their development, and (c) the soundness of the technical foundation. The public needs to be fully informed on studies, tests, and analyses that have been carried out worldwide and form the basis of the regulatory standards and requirements. This paper provides specific information aimed at improving the public perception of packages test standards

  5. Establishment and application of performance evaluation model for collection and transportation system of municipal solid waste

    Institute of Scientific and Technical Information of China (English)

    彭绪亚; 林晓东; 贾传兴; 王渝昆; 黄媛媛

    2009-01-01

    On the basis of analyzing the typical waste collection and transportation mode,the evaluation index system for performance of the waste collection and transportation system was proposed with three grades,which related to six factors,such as economic evaluation,high efficient evaluation,environmental impact assessment,resource evaluation,evaluation of security and emergency,evaluation of management and society. With the performance evaluation theory,the performance evaluation model of waste collection and transportation system was constructed,which quantified the grading standard of index and determined the index weight in analytic hierarchy process (AHP). After evaluating the waste collection and transportation system of the main districts of Chongqing city,the results show that the it has an excellent performance evaluation grade with very high performance level of three indices involving evaluation of management and society,environmental impact assessment,evaluation of security and emergency and quite low performance level of two indices that include high efficient evaluation and economic evaluation.

  6. Investigating conversational dynamics: Interactive alignment, Interpersonal synergy, and collective task performance

    DEFF Research Database (Denmark)

    Fusaroli, Riccardo; Tylén, Kristian

    2016-01-01

    This study investigates interpersonal processes underlying dialog by comparing two approaches, interactive alignment and interpersonal synergy, and assesses how they predict collective performance in a joint task. While the interactive alignment approach highlights imitative patterns between...... and their impact on collective performance in a corpus of task-oriented conversations. The results show statistical presence of patterns relevant for both approaches. However, synergetic aspects of dialog provide the best statistical predictors of collective performance and adding aspects of the alignment approach...... does not improve the model. This suggests that structural organization at the level of the interaction plays a crucial role in task-oriented conversations, possibly constraining and integrating processes related to alignment....

  7. Test anxiety and academic performance in chiropractic students.

    Science.gov (United States)

    Zhang, Niu; Henderson, Charles N R

    2014-01-01

    Objective : We assessed the level of students' test anxiety, and the relationship between test anxiety and academic performance. Methods : We recruited 166 third-quarter students. The Test Anxiety Inventory (TAI) was administered to all participants. Total scores from written examinations and objective structured clinical examinations (OSCEs) were used as response variables. Results : Multiple regression analysis shows that there was a modest, but statistically significant negative correlation between TAI scores and written exam scores, but not OSCE scores. Worry and emotionality were the best predictive models for written exam scores. Mean total anxiety and emotionality scores for females were significantly higher than those for males, but not worry scores. Conclusion : Moderate-to-high test anxiety was observed in 85% of the chiropractic students examined. However, total test anxiety, as measured by the TAI score, was a very weak predictive model for written exam performance. Multiple regression analysis demonstrated that replacing total anxiety (TAI) with worry and emotionality (TAI subscales) produces a much more effective predictive model of written exam performance. Sex, age, highest current academic degree, and ethnicity contributed little additional predictive power in either regression model. Moreover, TAI scores were not found to be statistically significant predictors of physical exam skill performance, as measured by OSCEs.

  8. Large scale and performance tests of the ATLAS online software

    International Nuclear Information System (INIS)

    Alexandrov; Kotov, V.; Mineev, M.; Roumiantsev, V.; Wolters, H.; Amorim, A.; Pedro, L.; Ribeiro, A.; Badescu, E.; Caprini, M.; Burckhart-Chromek, D.; Dobson, M.; Jones, R.; Kazarov, A.; Kolos, S.; Liko, D.; Lucio, L.; Mapelli, L.; Nassiakou, M.; Schweiger, D.; Soloviev, I.; Hart, R.; Ryabov, Y.; Moneta, L.

    2001-01-01

    One of the sub-systems of the Trigger/DAQ system of the future ATLAS experiment is the Online Software system. It encompasses the functionality needed to configure, control and monitor the DAQ. Its architecture is based on a component structure described in the ATLAS Trigger/DAQ technical proposal. Regular integration tests ensure its smooth operation in test beam setups during its evolutionary development towards the final ATLAS online system. Feedback is received and returned into the development process. Studies of the system behavior have been performed on a set of up to 111 PCs on a configuration which is getting closer to the final size. Large scale and performance test of the integrated system were performed on this setup with emphasis on investigating the aspects of the inter-dependence of the components and the performance of the communication software. Of particular interest were the run control state transitions in various configurations of the run control hierarchy. For the purpose of the tests, the software from other Trigger/DAQ sub-systems has been emulated. The author presents a brief overview of the online system structure, its components and the large scale integration tests and their results

  9. Relationships Between Anaerobic Performance, Field Tests and Game Performance of Sitting Volleyball Players

    Directory of Open Access Journals (Sweden)

    Marszalek Jolanta

    2015-12-01

    Full Text Available The aim of this study was to evaluate relationships between anaerobic performance, field tests, game performance and anthropometric variables of sitting volleyball players. Twenty elite Polish sitting volleyball players were tested using the 30 s Wingate Anaerobic Test for arm crank ergometer and participated in six physical field tests. Heights in position to block and to spike, as well as arm reach were measured. Players were observed during the game on the court in terms of effectiveness of the serve, block, attack, receive and defense. Pearson analysis and the Spearman's rank correlation coefficient were used. The strongest correlations were found between the chest pass test and mean power and peak power (r=.846; p=.001 and r=.708; p=.0005, respectively, and also between the T-test and peak power (r= −.718; p=.001. Mean power correlated with the 3 m test (r= −.540; p=.014, the 5 m test (r= −.592; p=.006, and the T-test (r= −.582; p=.007. Peak power correlated with the 3 m test (r= −.632; p=.003, the 5 m test (r= −.613; p=.004, speed & agility (r= −.552; p=.012 and speed & endurance (r=−.546; p=.013. Significant correlations were observed between anthropometric parameters and anaerobic performance variables (p≤.001, and also between anthropometric parameters and field tests (p≤.05. Game performance and physical fitness of sitting volleyball players depended on their anthropometric variables: reach of arms, the position to block and to spike. The chest pass test could be used as a non-laboratory field test of anaerobic performance of sitting volleyball players.

  10. Delay model and performance testing for FPGA carry chain TDC

    International Nuclear Information System (INIS)

    Kang Xiaowen; Liu Yaqiang; Cui Junjian Yang Zhangcan; Jin Yongjie

    2011-01-01

    Time-of-flight (TOF) information would improve the performance of PET (position emission tomography). TDC design is a key technique. It proposed Carry Chain TDC Delay model. Through changing the significant delay parameter of model, paper compared the difference of TDC performance, and finally realized Time-to-Digital Convertor (TDC) based on Carry Chain Method using FPGA EP2C20Q240C8N with 69 ps LSB, max error below 2 LSB. Such result could meet the TOF demand. It also proposed a Coaxial Cable Measuring method for TDC testing, without High-precision test equipment. (authors)

  11. Power Performance Test Report for the SWIFT Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, I.; Hur, J.

    2012-12-01

    This report summarizes the results of a power performance test that NREL conducted on the SWIFT wind turbine. This test was conducted in accordance with the International Electrotechnical Commission's (IEC) standard, Wind Turbine Generator Systems Part 12: Power Performance Measurements of Electricity Producing Wind Turbines, IEC 61400-12-1 Ed.1.0, 2005-12. However, because the SWIFT is a small turbine as defined by IEC, NREL also followed Annex H that applies to small wind turbines. In these summary results, wind speed is normalized to sea-level air density.

  12. Enhancement on Wingate Anaerobic Test Performance With Hyperventilation.

    Science.gov (United States)

    Leithäuser, Renate M; Böning, Dieter; Hütler, Matthias; Beneke, Ralph

    2016-07-01

    Relatively long-lasting metabolic alkalizing procedures such as bicarbonate ingestion have potential for improving performance in long-sprint to middle-distance events. Within a few minutes, hyperventilation can induce respiratory alkalosis. However, corresponding performance effects are missing or equivocal at best. To test a potential performance-enhancing effect of respiratory alkalosis in a 30-s Wingate Anaerobic Test (WAnT). 10 men (mean ± SD age 26.6 ± 4.9 y, height 184.4 ± 6.1 cm, body-mass test 1 80.7 ± 7.7 kg, body-mass test 2 80.4 ± 7.2 kg, peak oxygen uptake 3.95 ± 0.43 L/min) performed 2 WAnTs, 1 with and 1 without a standardized 15-min hyperventilation program pre-WAnT in randomized order separated by 1 wk. Compared with the control condition, hyperventilation reduced (all P respiratory alkalosis can enhance WAnT cycling sprint performance well in the magnitude of what is seen after successful bicarbonate ingestion.

  13. Indicators of Ceriodaphnia dubia chronic toxicity test performance and sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Rosebrock, M.M.; Bedwell, N.J.; Ausley, L.W. [North Carolina Division of Environmental Management, Raleigh, NC (United States)

    1994-12-31

    The North Carolina Division of Environmental Management has begun evaluation of the sensitivity of test results used for measuring chronic whole effluent toxicity in North Carolina wastewater discharges. Approximately 67% of 565 facilities required to monitor toxicity by an NPDES permit perform a Ceriodaphnia dubia chronic, single effluent concentration (pass/fail) analysis. Data from valid Ceriodaphnia dubia chronic pass/fail tests performed by approximately 20 certified biological laboratories and submitted by North Carolina NPDES permittees were recorded beginning January 1992. Control and treatment reproduction data from over 2,500 tests submitted since 1992 were analyzed to determine the minimum significant difference (MSD) at a 99% confidence level for each test and the percent reduction from the control mean that the MSD represents (%MSD) for each certified laboratory. Initial results for the 20 laboratories indicate that the average intralaboratory percent MSD ranges 12.72% (n = 367) to 34.91% (n = 7) with an average of 23.08%. Additionally, over 3,800 tests were analyzed to determine the coefficient of variation (CV) for control reproduction for each test and the average for each certified biological laboratory. Preliminary review indicates that average interlaboratory control reproduction CV values range from 10.59% (n = 367) to 31.08% (n = 572) with a mean of 20.35%. The statistics investigated are indicators of intra/interlaboratory performance and sensitivity of Ceriodaphnia chronic toxicity analyses.

  14. Verification Test of Hydraulic Performance for Reactor Coolant Pump

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Jun; Kim, Jae Shin; Ryu, In Wan; Ko, Bok Seong; Song, Keun Myung [Samjin Ind. Co., Seoul (Korea, Republic of)

    2010-01-15

    According to this project, basic design for prototype pump and model pump of reactor coolant pump and test facilities has been completed. Basic design for prototype pump to establish structure, dimension and hydraulic performance has been completed and through primary flow analysis by computational fluid dynamics(CFD), flow characteristics and hydraulic performance have been established. This pump was designed with mixed flow pump having the following design requirements; specific velocity(Ns); 1080.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 3115m{sup 3}/h, total head ; 26.3m, pump speed; 1710rpm, pump efficiency; 77.0%, Impeller out-diameter; 349mm, motor output; 360kw, design pressure; 17MPaG. The features of the pump are leakage free due to no mechanical seal on the pump shaft which insures reactor's safety and law noise level and low vibration due to no cooling fan on the motor which makes eco-friendly product. Model pump size was reduced to 44% of prototype pump for the verification test for hydraulic performance of reactor coolant pump and was designed with mixed flow pump and canned motor having the following design requirements; specific speed(NS); 1060.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 539.4m{sup 3}/h, total head; 21.0m, pump speed; 3476rpm, pump efficiency; 72.9%, Impeller out-diameter; 154mm, motor output; 55kw, design pressure; 1.0MPaG. The test facilities were designed for verification test of hydraulic performance suitable for pump performance test, homologous test, NPSH test(cavitation), cost down test and pressure pulsation test of inlet and outlet ports. Test tank was designed with testing capacity enabling up to 2000m{sup 3}/h and design pressure 1.0MPaG. Auxiliary pump was designed with centrifugal pump having capacity; 1100m{sup 3}/h, total head; 42.0m, motor output; 190kw

  15. Predictive testing of performance of metals in HTR service environments

    International Nuclear Information System (INIS)

    Kondo, T.; Shindo, M.; Tamura, M.; Tsuji, H.; Kurata, Y.; Tsukada, T.

    1982-01-01

    Status of the material testing in simulated HTGR environment is reviewed with special attention focused on the methodology of the prediction of performance in long time. Importance of controlling effective chemical potentials relations in the material-environmental interface is stressed in regard of the complex inter-dependent kinetic relation between oxidation and carbon transport. Based on the recent experimental observations, proposals are made to establish some procedures for conservative prediction of the metal performance

  16. Standardization of test conditions for gamma camera performance measurement

    International Nuclear Information System (INIS)

    Jordan, K.

    1982-02-01

    The way of measuring gamma camera performance is to use point sources or flood sources in air, often in combination with bar phantoms. This method has nothing in common with the use of a camera in clinical practice. Particularly in the case of low energy emitters, like Tc-99m, the influence of scattered radiation over the performance of cameras is very high. The IEC document 'Characteristics and test conditions of radionuclide imaging devices' is discussed

  17. Stereotype threat? Effects of inquiring about test takers' gender on conceptual test performance in physics

    Science.gov (United States)

    Maries, Alexandru; Singh, Chandralekha

    2015-12-01

    It has been found that activation of a stereotype, for example by indicating one's gender before a test, typically alters performance in a way consistent with the stereotype, an effect called "stereotype threat." On a standardized conceptual physics assessment, we found that asking test takers to indicate their gender right before taking the test did not deteriorate performance compared to an equivalent group who did not provide gender information. Although a statistically significant gender gap was present on the standardized test whether or not students indicated their gender, no gender gap was observed on the multiple-choice final exam students took, which included both quantitative and conceptual questions on similar topics.

  18. 78 FR 30899 - Agency Information Collection Activities; Comment Request; NCES Cognitive, Pilot, and Field Test...

    Science.gov (United States)

    2013-05-23

    ... requested data in the desired format. ED is soliciting comments on the proposed information collection... and methodologies. The procedures utilized to this effect include but are not limited to experiments... activities, pilot testing, exploratory interviews, experiments with questionnaire design, and usability...

  19. Performance test of solar-assisted ejector cooling system

    KAUST Repository

    Huang, Bin-Juine

    2014-03-01

    A solar-assisted ejector cooling/heating system (SACH-2k) is built and test result is reported. The solar-driven ejector cooling system (ECS) is connected in series with an inverter-type air conditioner (IAC). Several advanced technologies are developed in SACH-k2, including generator liquid level control in ECS, the ECS evaporator temperature control, and optimal control of fan power in cooling tower of ECS. From the field test results, the generator liquid level control performs quite well and keeps stable performance of ejector. The ECS evaporator temperature control also performs satisfactorily to keep ejector performance normally under low or fluctuating solar radiation. The fan power control system cooling tower performs stably and reduces the power consumption dramatically without affecting the ECS performance. The test results show that the overall system COPo including power consumptions of peripheral increases from 2.94-3.3 (IAC alone) to 4.06-4.5 (SACH-k2), about 33-43%. The highest COPo is 4.5. © 2013 Elsevier Ltd and IIR. All rights reserved.

  20. Effort, symptom validity testing, performance validity testing and traumatic brain injury.

    Science.gov (United States)

    Bigler, Erin D

    2014-01-01

    To understand the neurocognitive effects of brain injury, valid neuropsychological test findings are paramount. This review examines the research on what has been referred to a symptom validity testing (SVT). Above a designated cut-score signifies a 'passing' SVT performance which is likely the best indicator of valid neuropsychological test findings. Likewise, substantially below cut-point performance that nears chance or is at chance signifies invalid test performance. Significantly below chance is the sine qua non neuropsychological indicator for malingering. However, the interpretative problems with SVT performance below the cut-point yet far above chance are substantial, as pointed out in this review. This intermediate, border-zone performance on SVT measures is where substantial interpretative challenges exist. Case studies are used to highlight the many areas where additional research is needed. Historical perspectives are reviewed along with the neurobiology of effort. Reasons why performance validity testing (PVT) may be better than the SVT term are reviewed. Advances in neuroimaging techniques may be key in better understanding the meaning of border zone SVT failure. The review demonstrates the problems with rigidity in interpretation with established cut-scores. A better understanding of how certain types of neurological, neuropsychiatric and/or even test conditions may affect SVT performance is needed.

  1. The collection and analysis of transient test data using the mobile instrumentation data acquisition system (MIDAS)

    International Nuclear Information System (INIS)

    Uncapher, W.L.; Arviso, M.

    1995-01-01

    Packages designed to transport radioactive materials are required to survive exposure to environments defined in Code of Federal Regulations. Cask designers can investigate package designs through structural and thermal testing of full-scale packages, components, or representative models. The acquisition of reliable response data from instrumentation measurement devices is an essential part of this testing activity. Sandia National Laboratories, under the sponsorship of the US Department of Energy (DOE), has developed the Mobile Instrumentation Data Acquisition System (MIDAS) dedicated to the collection and processing of structural and thermal data from regulatory tests

  2. Computerized Tests of Team Performance and Crew Coordination Suitable for Military/Aviation Settings.

    Science.gov (United States)

    Lawson, Ben D; Britt, Thomas W; Kelley, Amanda M; Athy, Jeremy R; Legan, Shauna M

    2017-08-01

    The coordination of team effort on shared tasks is an area of inquiry. A number of tests of team performance in challenging environments have been developed without comparison or standardization. This article provides a systematic review of the most accessible and usable low-to-medium fidelity computerized tests of team performance and determines which are most applicable to military- and aviation-relevant research, such as studies of group command, control, communication, and crew coordination. A search was conducted to identify computerized measures of team performance. In addition to extensive literature searches (DTIC, Psychinfo, PubMed), the authors reached out to team performance researchers at conferences and through electronic communication. Identified were 57 potential tests according to 6 specific selection criteria (e.g., the requirement for automated collection of team performance and coordination processes, the use of military-relevant scenarios). The following seven tests (listed alphabetically) were considered most suitable for military needs: Agent Enabled Decision Group Environment (AEDGE), C3Conflict, the C3 (Command, Control, & Communications) Interactive Task for Identifying Emerging Situations (NeoCITIES), Distributed Dynamic Decision Making (DDD), Duo Wondrous Original Method Basic Awareness/Airmanship Test (DuoWOMBAT), the Leader Development Simulator (LDS), and the Planning Task for Teams (PLATT). Strengths and weaknesses of these tests are described and recommendations offered to help researchers identify the test most suitable for their particular needs. Adoption of a few standard computerized test batteries to study team performance would facilitate the evaluation of interventions intended to enhance group performance in multiple challenging military and aerospace operational environments.Lawson BD, Britt TW, Kelley AM, Athy JR, Legan SM. Computerized tests of team performance and crew coordination suitable for military/aviation settings

  3. Fluid flow measurements of Test Series A and B for the Small Scale Seal Performance Tests

    International Nuclear Information System (INIS)

    Peterson, E.W.; Lagus, P.L.; Lie, K.

    1987-12-01

    The degree of waste isolation achieved by a repository seal system is dependent upon the fluid flow characteristics, or permeability, of the seals. In order to obtain meaningful, site-specific data on the performance of various possible seal system components, a series of in situ experiments called the Small Scale Seal Performance Tests (SSSPT) are being conducted at the Waste Isolation Pilot Plant (WIPP). This report contains the results of gas flow, tracer penetration, and brine flow tests conducted on concrete seals in vertical (Test Series A) and horizontal (Test Series B) configurations. The test objectives were to evaluate the seal performance and to determine if there existed scaling effects which could influence future SSSPT designs. 3 refs., 77 figs

  4. Eurados trial performance test for neutron personal dosimetry

    DEFF Research Database (Denmark)

    Bordy, J.M.; Stadtmann, H.; Ambrosi, P.

    2001-01-01

    This paper reports on the results of a neutron trial performance test sponsored by the European Commission and organised by EURADOS. As anticipated, neutron dosimetry results were very dependent on the dosemeter type and the dose calculation algorithm. Fast neutron fields were generally well...

  5. Effective Rating Scale Development for Speaking Tests: Performance Decision Trees

    Science.gov (United States)

    Fulcher, Glenn; Davidson, Fred; Kemp, Jenny

    2011-01-01

    Rating scale design and development for testing speaking is generally conducted using one of two approaches: the measurement-driven approach or the performance data-driven approach. The measurement-driven approach prioritizes the ordering of descriptors onto a single scale. Meaning is derived from the scaling methodology and the agreement of…

  6. Fuel performance analysis for the HAMP-1 mini plate test

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Byoung Jin; Tahka, Y. W.; Yim, J. S.; Lee, B. H. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    U-7wt%Mo/Al- 5wt%Si dispersion fuel with 8gU/cm{sup 3} is chosen to achieve more efficiency and higher performance than the conventional U{sub 3}Si{sub 2} fuel. As part of the fuel qualification program for the KiJang research reactor (KJRR), three irradiation tests with mini-plates are on the way at the High-flux Advanced Neutron Application Reactor (HANARO). The first test among three HANARO Mini-Plate Irradiation tests (HAMP-1, 2, 3) has completed. PLATE code has been initially developed to analyze the thermal performance of high density U-Mo/Al dispersion fuel plates during irradiation [1]. We upgraded the PLATE code with the latest irradiation results which were implemented by corrosion, thermal conductivity and swelling model. Fuel performance analysis for HAMP-1 was conducted with updated PLATE. This paper presents results of performance evaluation of the HAMP-1. Maximum fuel temperature was obtained 136 .deg., which is far below the preset limit of 200 .deg. for the irradiation test. The meat swelling and corrosion thickness was also confirmed that the developed fuel would behave as anticipated.

  7. 40 CFR 60.58b - Compliance and performance testing.

    Science.gov (United States)

    2010-07-01

    ... accuracy requirement). (5) The quality assurance procedures of appendix F of this part except for section 5.1.1 (relative accuracy test audit) shall apply to the monitor. (6) If carbon dioxide is selected for... related activities for the purpose of improving facility performance or advancing the state-of-the-art for...

  8. Performance test of solar-assisted ejector cooling system

    KAUST Repository

    Huang, Bin-Juine; Ton, Wei-Zhe; Wu, Chen-Chun; Ko, Hua-Wei; Chang, Hsien-Shun; Hsu, Hang-Yuen; Liu, Jen-Hao; Wu, Jia-Hung; Yen, Rue-Her

    2014-01-01

    are developed in SACH-k2, including generator liquid level control in ECS, the ECS evaporator temperature control, and optimal control of fan power in cooling tower of ECS. From the field test results, the generator liquid level control performs quite well

  9. Modelling of LOCA Tests with the BISON Fuel Performance Code

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, Richard L [Idaho National Laboratory; Pastore, Giovanni [Idaho National Laboratory; Novascone, Stephen Rhead [Idaho National Laboratory; Spencer, Benjamin Whiting [Idaho National Laboratory; Hales, Jason Dean [Idaho National Laboratory

    2016-05-01

    BISON is a modern finite-element based, multidimensional nuclear fuel performance code that is under development at Idaho National Laboratory (USA). Recent advances of BISON include the extension of the code to the analysis of LWR fuel rod behaviour during loss-of-coolant accidents (LOCAs). In this work, BISON models for the phenomena relevant to LWR cladding behaviour during LOCAs are described, followed by presentation of code results for the simulation of LOCA tests. Analysed experiments include separate effects tests of cladding ballooning and burst, as well as the Halden IFA-650.2 fuel rod test. Two-dimensional modelling of the experiments is performed, and calculations are compared to available experimental data. Comparisons include cladding burst pressure and temperature in separate effects tests, as well as the evolution of fuel rod inner pressure during ballooning and time to cladding burst. Furthermore, BISON three-dimensional simulations of separate effects tests are performed, which demonstrate the capability to reproduce the effect of azimuthal temperature variations in the cladding. The work has been carried out in the frame of the collaboration between Idaho National Laboratory and Halden Reactor Project, and the IAEA Coordinated Research Project FUMAC.

  10. Post-test analysis for the APR1400 LBLOCA DVI performance test using MARS

    International Nuclear Information System (INIS)

    Bae, Kyoo Hwan; Lee, Y. J.; Kim, H. C.; Bae, Y. Y.; Park, J. K.; Lee, W.

    2002-03-01

    Post-test analyses using a multi-dimensional best-estimate analysis code, MARS, are performed for the APR1400 LBLOCA DVI (Direct Vessel Injection) performance tests. This report describes the code evaluation results for the test data of various void height tests and direct bypass tests that have been performed at MIDAS test facility. MIDAS is a scaled test facility of APR1400 with the objective of identifying multi-dimensional thermal-hydraulic phenomena in the downcomer during the reflood conditions of a large break LOCA. A modified linear scale ratio was applied in its construction and test conditions. The major thermal-hydraulic parameters such as ECC bypass fraction, steam condensation fraction, and temperature distributions in downcomer are compared and evaluated. The evaluation results of MARS code for the various test cases show that: (a) MARS code has an advanced modeling capability of well predicting major multi-dimensional thermal-hydraulic phenomena occurring in the downcomer, (b) MARS code under-predicts the steam condensation rates, which in turn causes to over-predict the ECC bypass rates. However, the trend of decrease in steam condensation rate and increase in ECC bypass rate in accordance with the increase in steam flow rate, and the calculation results of the ECC bypass rates under the EM analysis conditions generally agree with the test data

  11. Collective dose as a performance measure for occupational radiation protection programs: Issues and recommendations

    International Nuclear Information System (INIS)

    Strom, D.J.; Harty, R.; Hickey, E.E.; Martin, J.B.; Peffers, M.S.; Kathren, R.L.

    1998-07-01

    Collective dose is one of the performance measures used at many US Department of Energy (DOE) contractor facilities to quantitatively assess the objectives of the radiation protection program. It can also be used as a management tool to improve the program for keeping worker doses as low as reasonably achievable (ALARA). Collective dose is used here to mean the sum of all total effective dose equivalent values for all workers in a specified group over a specified time. It is often used as a surrogate estimate of radiological risk. In principle, improvements in radiation protection programs and procedures will result in reduction of collective dose, all other things being equal. Within the DOE, most frequently, a single collective dose number, which may or may not be adjusted for workload and other factors, is used as a performance measure for a contractor. The purpose of this report is to evaluate the use of collective dose as a performance measure for ALARA programs at DOE sites

  12. SP-100 Fuel Pin Performance: Results from Irradiation Testing

    Science.gov (United States)

    Makenas, Bruce J.; Paxton, Dean M.; Vaidyanathan, Swaminathan; Marietta, Martin; Hoth, Carl W.

    1994-07-01

    A total of 86 experimental fuel pins with various fuel, liner, and cladding candidate materials have been irradiated in the Experimental Breeder Reactor-II (EBR-II) and the Fast Flux Test Facility (FFTF) reactor as part of the SP-100 fuel pin irradiation testing program. Postirradiation examination results from these fuel pins are key in establishing performance correlations and demonstrating the lifetime and safety of the reactor fuel system. This paper provides a brief description of the in-reactor fuel pin tests and presents the most recent irradiation data on the performance of wrought rhenium (Re) liner material and high density UN fuel at goal burnup of 6 atom percent (at. %). It also provides an overview of the significant variety of other fuel/liner/cladding combinations which were irradiated as part of this program and which may be of interest to more advanced efforts.

  13. THE INVESTIGATION OF BRUCELLA ANTIBODY WITH MILK RING TEST AND AGGLUTINATION TEST IN MILK COLLECTED FROM SAMSUN REGION

    Directory of Open Access Journals (Sweden)

    Goknur TERZI

    2006-06-01

    Full Text Available In this study Brucella antibodies were investigated with agglutination test (Whey-AT and Milk Ring Test (MRT in a total of 100 milk samples as 50 of cow milk and 50 of goat milk collected from center and villages of Samsun. According to MRT Brucella antibodies was positive at 10 samples (20 % of cow milk and 6 samples (12 % of goat milk. In cow milk, 4 (8 % positive, 3 (6 % suspicious and 43 (86 % negative samples; in goat milk 3 (6 % positive, 2 (4 % suspicious and 45 (90 % negative samples were determined according to antibodies titre of serum agglutination test (Whey-AT. [TAF Prev Med Bull 2006; 5(3.000: 196-203

  14. Walk test and school performance in mouth-breathing children.

    Science.gov (United States)

    Boas, Ana Paula Dias Vilas; Marson, Fernando Augusto de Lima; Ribeiro, Maria Angela Gonçalves de Oliveira; Sakano, Eulália; Conti, Patricia Blau Margosian; Toro, Adyléia Dalbo Contrera; Ribeiro, José Dirceu

    2013-01-01

    In recent decades, many studies on mouth breathing (MB) have been published; however, little is known about many aspects of this syndrome, including severity, impact on physical and academic performances. Compare the physical performance in a six minutes walk test (6MWT) and the academic performance of MB and nasal-breathing (NB) children and adolescents. This is a descriptive, cross-sectional, and prospective study with MB and NB children submitted to the 6MWT and scholar performance assessment. We included 156 children, 87 girls (60 NB and 27 MB) and 69 boys (44 NB and 25 MB). Variables were analyzed during the 6MWT: heart rate (HR), respiratory rate, oxygen saturation, distance walked in six minutes and modified Borg scale. All the variables studied were statistically different between groups NB and MB, with the exception of school performance and HR in 6MWT. MB affects physical performance and not the academic performance, we noticed a changed pattern in the 6MWT in the MB group. Since the MBs in our study were classified as non-severe, other studies comparing the academic performance variables and 6MWT are needed to better understand the process of physical and academic performances in MB children.

  15. Standardization of test conditions for gamma camera performance measurement

    International Nuclear Information System (INIS)

    Jordan, K.

    1980-01-01

    The actual way of measuring gamma camera performance is to use point sources or flood sources in air, often in combination with bar phantoms. This method mostly brings best performance parameters for cameras but it has nothing in common with the use of a camera in clinical practice. Particular in the case of low energy emitters, like Tc-99m, the influence of scattered radiation over the performance of cameras is very high. Therefore it is important to have test conditions of radionuclide imaging devices, that will approach as best as practicable the measuring conditions in clinical applications. It is therefore a good news that the International Electrochemical Commission IEC has prepared a draft 'Characteristics and test conditions of radionuclide imaging devices' which is now submitted to the national committees for formal approval under the Six Months' Rule. Some essential points of this document are discussed in the paper. (orig.) [de

  16. Clock Face Drawing Test Performance in Children with ADHD

    Directory of Open Access Journals (Sweden)

    Ahmad Ghanizadeh

    2013-01-01

    Full Text Available  Introduction: The utility and discriminatory pattern of the clock face drawing test in ADHD is unclear. This study therefore compared Clock Face Drawing test performance in children with ADHD and controls.   Material & methods: 95 children with ADHD and 191 school children were matched for gender ratio and age. ADHD symptoms severities were assessed using DSM-IV ADHD checklist and their intellectual functioning was assessed. The participants completed three clock-drawing tasks, and the following four functions were assessed: Contour score, Numbers score, Hands setting score, and Center score    Results: All the subscales scores of the three clock drawing tests of the ADHD group were lower than that of the control group. In ADHD children, inattention and hyperactivity/impulsivity scores were not related with free drawn clock test scores. When pre-drawn contour test was performed, inattentiveness score was statistically associated with Number score. None of the other variables of age, gender, intellectual functioning, and hand use preference were associated with Numbers score. In pre-drawn clock, no association of ADHD symptoms with any CDT subscales was significant. In addition, more errors are observed with free drawn clock and Pre-drawn contour than pre-drawn clock.    Conclusion: Putting Numbers and Hands setting are more sensitive measures to screen ADHD than Contour and Center drawing. Test performance, except Hands setting, may have already reached a developmental plateau. It is probable that Hand setting deficit in children with ADHD may not decrease from age 8 to 14 years. Performance of children with ADHD is associated with the complexity of CDT.

  17. Clock face drawing test performance in children with ADHD.

    Science.gov (United States)

    Ghanizadeh, Ahmad; Safavi, Salar; Berk, Michael

    2013-01-01

    The utility and discriminatory pattern of the clock face drawing test in ADHD is unclear. This study therefore compared Clock Face Drawing test performance in children with ADHD and controls. 95 school children with ADHD and 191 other children were matched for gender ratio and age. ADHD symptoms severities were assessed using DSM-IV ADHD checklist and their intellectual functioning was assessed. The participants completed three clock-drawing tasks, and the following four functions were assessed: Contour score, Numbers score, Hands setting score, and Center score. All the subscales scores of the three clock drawing tests of the ADHD group were lower than that of the control group. In ADHD children, inattention and hyperactivity/ impulsivity scores were not related to free drawn clock test scores. When pre-drawn contour test was performed, inattentiveness score was statistically associated with Number score while none of the other variables of age, gender, intellectual functioning, and hand use preference were associated with that kind of score. In pre-drawn clock, no association of ADHD symptoms with any CDT subscales found significant. In addition, more errors are observed with free drawn clock and Pre-drawn contour than pre-drawn clock. Putting Numbers and Hands setting are more sensitive measures to screen ADHD than Contour and Center drawing. Test performance, except Hands setting, may have already reached a developmental plateau. It is probable that Hand setting deficit in children with ADHD may not decrease from age 8 to 14 years. Performance of children with ADHD is associated with complexity of CDT.

  18. Collective Female Identities in Discussions about Pussy Riot’s Performance

    Directory of Open Access Journals (Sweden)

    Anna Agaltsova

    2014-12-01

    Full Text Available In this paper, I address the issue of collective female identities in contemporary Russia. The Pussy Riot performance is regarded as a critical event that serves as a trigger for certain 'groupness'. Taking critical event perspectives avoids framing the respondents with the researcher's predetermined categories. The empirical data is collected via collective interviews with the diverse group of Moscovites. Analysis highlights the domination of an authoritarian/collectivistic interpretative repertoire in older participants' discussions about the performance, which has resulted in the articulation of the image of the disadvantaged female and the denial of women's agency. The younger participants, being familiar with a co-existing liberal interpretative repertoire, have continued to use a conservative repertoire to discuss Pussy Riot. This and a general lack of gender problematisation in the interviews indicate that feminist discourse is not at all widespread in the Moscovites' everyday discourse.

  19. Embodied discourse in the bourgeois museum: performative spaces at the Ordrupgaard collection

    Directory of Open Access Journals (Sweden)

    Rasmus Kjærboe

    2015-04-01

    Full Text Available In a suburb just north of Copenhagen is Ordrupgaard. At the inauguration in 1918, it was arguably the best collection of impressionism open to the public outside France and the USA. This paper has two goals: First, to reconstruct and analyze the important yet little known original exhibition ensemble at Ordrupgaard, and second, to develop a view of the bourgeois art exhibition as a performative ritual. Building on ideas of exhibition narratives and visitor involvement derived from diverse work done within museology and museum studies, the paper proposes a close examination of how collective memory and performative embodiment drive exhibition experience. From this, Ordrupgaard emerges as an early example of a museum that offers its audience the possibility of a pleasurable enactment of middle class identity within a setting encompassing nature, art and architecture. The case of a small collection museum therefore reveals important mechanics at work within a potentially much larger field of institutions.

  20. 75 FR 21716 - Agency Information Collection; Activity Under OMB Review; Airline Service Quality Performance...

    Science.gov (United States)

    2010-04-26

    ... RITA 2008-0002] Agency Information Collection; Activity Under OMB Review; Airline Service Quality... Reports'' pursuant to 14 CFR 234.4 and 234.6. These reports are used to monitor the quality of air service.... SUPPLEMENTARY INFORMATION: OMB Approval No. 2138-0041. Title: Airline Service Quality Performance--Part 234...

  1. 75 FR 41920 - Agency Information Collection; Activity Under OMB Review; Airline Service Quality Performance...

    Science.gov (United States)

    2010-07-19

    ... DEPARTMENT OF TRANSPORTATION Research & Innovative Technology Administration [Docket ID Number RITA 2008-0002] Agency Information Collection; Activity Under OMB Review; Airline Service Quality...: Airline Service Quality Performance--Part 234. Form No.: BTS Form 234. Type Of Review: Re-instatement of...

  2. 77 FR 18306 - Agency Information Collection; Activity Under OMB Review; Airline Service Quality Performance

    Science.gov (United States)

    2012-03-27

    ... 2008-0002] Agency Information Collection; Activity Under OMB Review; Airline Service Quality...'' pursuant to 14 CFR 234.4 and 234.6. These reports are used to monitor the quality of air service that... INFORMATION: OMB Approval No. 2138-0041. Title: Airline Service Quality Performance Reports--Part 234. Form No...

  3. The Variable and Changing Status of Performance Art Relics and Artifacts in Museum Collections

    DEFF Research Database (Denmark)

    Cone, Louise

    2017-01-01

    The status of an artwork in a museum collection is variable and contingent upon factors and parameters that are specific not only to the logic of the museum world but also to factors extrinsic to the museum. In particular older performance art 'relics' are subject to contextual interpretations...

  4. Monitoring the Performance of the Pedestrian Transfer Function of Train Stations Using Automatic Fare Collection Data

    NARCIS (Netherlands)

    Van den Heuvel, J.P.A.; Hoogenraad, J.H.

    2014-01-01

    Over the last years all train stations in The Netherlands have been equipped with automatic fare collection gates and/or validators. All public transport passengers use a smart card to pay their fare. In this paper we present a monitor for the performance of the pedestrian function of train stations

  5. MOTIVATION AND PERFORMANCE IN PHYSICAL EDUCATION: AN EXPERIMENTAL TEST

    Directory of Open Access Journals (Sweden)

    Juan A. Moreno

    2010-03-01

    Full Text Available The purpose of this study was to analyse, experimentally, the relationships between motivation and performance in a lateral movement test in physical education. The study group consisted of 363 students (227 boys and 136 girls, aged between 12 and 16, who were randomly divided into three groups: an experimental group in which an incremental ability belief was induced, another experimental group in which an entity ability belief was induced, and a control group where there was no intervention. Measurements were made of situational intrinsic motivation, perceived competence in executing the task and performance. The results revealed that the incremental group reported higher scores on the situational intrinsic motivation scale. The entity group demonstrated better performance in the first test attempt than the incremental group but, in the second attempt, the performance was similar in the different groups. Perhaps the initial differences in performance disappeared because the incremental group counted on improving in the second attempt. These results are discussed in relation to the intensity with which the teacher conveys information relating to incremental ability belief of the pupil to increase intrinsic motivation and performance

  6. Extensive tests of Hybrid Photon Detectors (HPD) used to collect Cherenkov light

    International Nuclear Information System (INIS)

    Borsato, E.; Buccheri, A.; DalCorso, F.; Ferroni, F.; Iacovella, F.; Mazzoni, M.A.; Morandin, M.; Morganti, S.; Piredda, G.; Posocco, M.; Santacesaria, R.; Stroili, R.; Torassa, E.; Voci, C.

    1997-01-01

    The principle of operation of a newly developed proximity focused Hybrid Photon Detector is described. The HPD characteristics, performance and calibration are reported. Results from beam tests of aerogel threshold counters read out by HPD and the particle identification performance are presented. (orig.)

  7. Predicting neuropsychological test performance on the basis of temporal orientation.

    Science.gov (United States)

    Ryan, Joseph J; Glass, Laura A; Bartels, Jared M; Bergner, CariAnn M; Paolo, Anthony M

    2009-05-01

    Temporal orientation is often disrupted in the context of psychiatric or neurological disease; tests assessing this function are included in most mental status examinations. The present study examined the relationship between scores on the Temporal Orientation Scale (TOS) and performance on a battery of tests that assess memory, language, and cognitive functioning in a sample of patients with Alzheimer's disease (N = 55). Pearson-product moment correlations showed that, in all but two instances, the TOS was significantly correlated with each neuropsychological measure, p values < or = .05. Also, severely disoriented (i.e., TOS score < or = -8) patients were consistently 'impaired' on memory tests but not on tests of language and general cognitive functioning.

  8. Collection and Characterization of Samples for Establishment of a Serum Repository for Lyme Disease Diagnostic Test Development and Evaluation

    Science.gov (United States)

    Molins, Claudia R.; Sexton, Christopher; Young, John W.; Ashton, Laura V.; Pappert, Ryan; Beard, Charles B.

    2014-01-01

    Serological assays and a two-tiered test algorithm are recommended for laboratory confirmation of Lyme disease. In the United States, the sensitivity of two-tiered testing using commercially available serology-based assays is dependent on the stage of infection and ranges from 30% in the early localized disease stage to near 100% in late-stage disease. Other variables, including subjectivity in reading Western blots, compliance with two-tiered recommendations, use of different first- and second-tier test combinations, and use of different test samples, all contribute to variation in two-tiered test performance. The availability and use of sample sets from well-characterized Lyme disease patients and controls are needed to better assess the performance of existing tests and for development of improved assays. To address this need, the Centers for Disease Control and Prevention and the National Institutes of Health prospectively collected sera from patients at all stages of Lyme disease, as well as healthy donors and patients with look-alike diseases. Patients and healthy controls were recruited using strict inclusion and exclusion criteria. Samples from all included patients were retrospectively characterized by two-tiered testing. The results from two-tiered testing corroborated the need for novel and improved diagnostics, particularly for laboratory diagnosis of earlier stages of infection. Furthermore, the two-tiered results provide a baseline with samples from well-characterized patients that can be used in comparing the sensitivity and specificity of novel diagnostics. Panels of sera and accompanying clinical and laboratory testing results are now available to Lyme disease serological test users and researchers developing novel tests. PMID:25122862

  9. Raven's Test Performance of Sub-Saharan Africans: Average Performance, Psychometric Properties, and the Flynn Effect

    Science.gov (United States)

    Wicherts, Jelte M.; Dolan, Conor V.; Carlson, Jerry S.; van der Maas, Han L. J.

    2010-01-01

    This paper presents a systematic review of published data on the performance of sub-Saharan Africans on Raven's Progressive Matrices. The specific goals were to estimate the average level of performance, to study the Flynn Effect in African samples, and to examine the psychometric meaning of Raven's test scores as measures of general intelligence.…

  10. Performance testing of supercapacitors: Important issues and uncertainties

    Science.gov (United States)

    Zhao, Jingyuan; Gao, Yinghan; Burke, Andrew F.

    2017-09-01

    Supercapacitors are a promising technology for high power energy storage, which have been used in some industrial and vehicles applications. Hence, it is important that information concerning the performance of supercapacitors be detailed and reliable so system designers can make rational decisions regarding the selection of the energy storage components. This paper is concerned with important issues and uncertainties regarding the performance testing of supercapacitors. The effect of different test procedures on the measured characteristics of both commercial and prototype supercapacitors including hybrid supercapacitors have been studied. It was found that the test procedure has a relatively minor effect on the capacitance of carbon/carbon devices and a more significant effect on the capacitance of hybrid supercapacitors. The device characteristic with the greatest uncertainty is the resistance and subsequently the claimed power capability of the device. The energy density should be measured by performing constant power discharges between appropriate voltage limits. This is particularly important in the case of hybrid supercapacitors for which the energy density is rate dependent and the simple relationship E = ½CV2 does not yield accurate estimates of the energy stored. In general, most of the important issues for testing carbon/carbon devices become more serious for hybrid supercapacitors.

  11. Performance test of a ceramic turbo-viscous pump

    International Nuclear Information System (INIS)

    Abe, Tetsuya; Hiroki, Seiji; Murakami, Yoshio; Shiraishi, Shigeyuki; Totoura, Sadayuki; Ohtaki, Takashi.

    1994-01-01

    In the special fields of nuclear fusion facilities and semiconductor production installation, the development of new vacuum pumps which can cope with strong magnetic fields, high temperature gas and corrosive gas is demanded. Mitsubishi Heavy Industries Ltd. has advanced the development of ceramic turbo-molecular pumps and ceramic turbo-viscous pumps, which use ceramic rotors and gas bearings since 1985. The evaluation test of the ceramic turbo-viscous vacuum pump CT-3000H which can evacuate from atmospheric pressure to high vacuum with one pump was carried out, and the experimental results on the performance and the reliability were obtained, therefore, those are reported in this paper. The structure, specification and features of the CT-3000H are shown. The exhaust performance test of the pump was carried out in conformity with the standard of the Vacuum Society of Japan, JVIS 005 'Method of performance test for turbo-molecular pumps'. The gases used were nitrogen and helium. The results are shown. The exhaust test from atmospheric pressure was carried out by two methods, and the results are shown. (K.I.)

  12. Multiphase pumping: indoor performance test and oilfield application

    Science.gov (United States)

    Kong, Xiangling; Zhu, Hongwu; Zhang, Shousen; Li, Jifeng

    2010-03-01

    Multiphase pumping is essentially a means of adding energy to the unprocessed effluent which enables the liquid and gas mixture to be transported over a long distances without prior separation. A reduction, consolidation, or elimination of the production infrastructure, such as separation equipments and offshore platforms can be developed more economically. Also it successfully lowed the backpressure of wells, revived dead wells and improved the production and efficiency of oilfield. This paper reviews the issues related to indoor performance test and an oilfield application of the helico-axial multiphase pump designed by China University of Petroleum (Beijing). Pump specification and its hydraulic design are given. Results of performance testing under different condition, such as operational speed and gas volume fraction (GVF) etc are presented. Experimental studies on combination of theoretical analysis showed the multiphase pump satisfies the similitude rule, which can be used in the development of new MPP design and performance prediction. Test results showed that rising the rotation speed and suction pressure could better its performance, pressure boost improved, high efficiency zone expanding and the flow rate related to the optimum working condition increased. The pump worked unstable as GVF increased to a certain extent and slip occurred between two phases in the pump, creating surging and gas lock at a high GVF. A case of application in Nanyang oilfield is also studied.

  13. Hydrogen Field Test Standard: Laboratory and Field Performance

    Science.gov (United States)

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are

  14. Wafer-level radiometric performance testing of uncooled microbolometer arrays

    Science.gov (United States)

    Dufour, Denis G.; Topart, Patrice; Tremblay, Bruno; Julien, Christian; Martin, Louis; Vachon, Carl

    2014-03-01

    A turn-key semi-automated test system was constructed to perform on-wafer testing of microbolometer arrays. The system allows for testing of several performance characteristics of ROIC-fabricated microbolometer arrays including NETD, SiTF, ROIC functionality, noise and matrix operability, both before and after microbolometer fabrication. The system accepts wafers up to 8 inches in diameter and performs automated wafer die mapping using a microscope camera. Once wafer mapping is completed, a custom-designed quick insertion 8-12 μm AR-coated Germanium viewport is placed and the chamber is pumped down to below 10-5 Torr, allowing for the evaluation of package-level focal plane array (FPA) performance. The probe card is electrically connected to an INO IRXCAM camera core, a versatile system that can be adapted to many types of ROICs using custom-built interface printed circuit boards (PCBs). We currently have the capability for testing 384x288, 35 μm pixel size and 160x120, 52 μm pixel size FPAs. For accurate NETD measurements, the system is designed to provide an F/1 view of two rail-mounted blackbodies seen through the Germanium window by the die under test. A master control computer automates the alignment of the probe card to the dies, the positioning of the blackbodies, FPA image frame acquisition using IRXCAM, as well as data analysis and storage. Radiometric measurement precision has been validated by packaging dies measured by the automated probing system and re-measuring the SiTF and Noise using INO's pre-existing benchtop system.

  15. Test objects for evaluating the performance of radiological imaging systems. Leeds radiological test objects

    International Nuclear Information System (INIS)

    Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.

    1985-01-01

    A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)

  16. 9977 TYPE B PACKAGING INTERNAL DATA COLLECTION FEASIBILITY TESTING - MAGNETIC FIELD COMMUNICATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Shull, D.

    2012-06-18

    The objective of this report is to document the findings from proof-of-concept testing performed by the Savannah River National Laboratory (SRNL) R&D Engineering and Visible Assets, Inc. for the DOE Packaging Certification Program (PCP) to determine if RuBee (IEEE 1902.1) tags and readers could be used to provide a communication link from within a drum-style DOE certified Type B radioactive materials packaging. A Model 9977 Type B Packaging was used to test the read/write capability and range performance of a RuBee tag and reader. Testing was performed with the RuBee tags placed in various locations inside the packaging including inside the drum on the outside of the lid of the containment vessel and also inside of the containment vessel. This report documents the test methods and results. A path forward will also be recommended.

  17. Agility in Team Sports: Testing, Training and Factors Affecting Performance.

    Science.gov (United States)

    Paul, Darren J; Gabbett, Tim J; Nassis, George P

    2016-03-01

    Agility is an important characteristic of team sports athletes. There is a growing interest in the factors that influence agility performance as well as appropriate testing protocols and training strategies to assess and improve this quality. The objective of this systematic review was to (1) evaluate the reliability and validity of agility tests in team sports, (2) detail factors that may influence agility performance, and (3) identify the effects of different interventions on agility performance. The review was undertaken in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We conducted a search of PubMed, Google Scholar, Science Direct, and SPORTDiscus databases. We assessed the methodological quality of intervention studies using a customized checklist of assessment criteria. Intraclass correlation coefficient values were 0.80-0.91, 0.10-0.81, and 0.81-0.99 for test time using light, video, and human stimuli. A low-level reliability was reported for youth athletes using the video stimulus (0.10-0.30). Higher-level participants were shown to be, on average, 7.5% faster than their lower level counterparts. Reaction time and accuracy, foot placement, and in-line lunge movement have been shown to be related to agility performance. The contribution of strength remains unclear. Efficacy of interventions on agility performance ranged from 1% (vibration training) to 7.5% (small-sided games training). Agility tests generally offer good reliability, although this may be compromised in younger participants responding to various scenarios. A human and/or video stimulus seems the most appropriate method to discriminate between standard of playing ability. Decision-making and perceptual factors are often propositioned as discriminant factors; however, the underlying mechanisms are relatively unknown. Research has focused predominantly on the physical element of agility. Small-sided games and video training may offer effective

  18. 1997 Performance Testing of Multi-Metal Continuous Emissions Monitors

    International Nuclear Information System (INIS)

    1998-01-01

    Five prototype and two commercially available multi-metals continuous emissions monitors (CEMs) were tested in September 1997 at the Rotary Kiln Incinerator Simulator facility at the EPA National Risk Management Research Laboratory, Research Triangle Park, North Carolina. The seven CEMs were tested side by side in a long section of duct following the secondary combustion chamber of the RKIS. Two different concentrations of six toxic metals were introduced into the incinerator-approximately 15 and 75 g/dscm of arsenic, beryllium, cadmium, chromium, lead, and mercury (We also tested for antimony but we are not reporting on it here because EPA recently dropped antimony from the list of metals addressed by the draft MACT rule). These concentrations were chosen to be close to emission standards in the draft MACT rule and the estimated Method Detection Limit (MDL) required of a CEM for regulatory compliance purposes. Results from this test show that no CEMs currently meet the performance specifications in the EPA draft MACT rule for hazardous waste incinerators. Only one of the CEMs tested was able to measure all six metals at the concentrations tested. Even so, the relative accuracy of this CEM varied between 35% and 100%, not 20% or less as required in the EPA performance specification. As a result, we conclude that no CEM is ready for long-term performance validation for compliance monitoring applications. Because sampling and measuring Hg is a recurring problem for multi-metal CEMs as well as Hg CEMs, we recommended that developers participate in a 1998 DOE-sponsored workshop to solve these and other common CEM measurement issues

  19. Comparison of driving simulator performance and neuropsychological testing in narcolepsy.

    Science.gov (United States)

    Kotterba, Sylvia; Mueller, Nicole; Leidag, Markus; Widdig, Walter; Rasche, Kurt; Malin, Jean-Pierre; Schultze-Werninghaus, Gerhard; Orth, Maritta

    2004-09-01

    Daytime sleepiness and cataplexy can increase automobile accident rates in narcolepsy. Several countries have produced guidelines for issuing a driving license. The aim of the study was to compare driving simulator performance and neuropsychological test results in narcolepsy in order to evaluate their predictive value regarding driving ability. Thirteen patients with narcolepsy (age: 41.5+/-12.9 years) and 10 healthy control patients (age: 55.1+/-7.8 years) were investigated. By computer-assisted neuropsychological testing, vigilance, alertness and divided attention were assessed. In a driving simulator patients and controls had to drive on a highway for 60 min (mean speed of 100 km/h). Different weather and daytime conditions and obstacles were presented. Epworth Sleepiness Scale-Scores were significantly raised (narcolepsy patients: 16.7+/-5.1, controls: 6.6+/-3.6, P divided attention (56.9+/-25.4) and vigilance (58.7+/-26.8) were in a normal range. There was, however, a high inter-individual difference. There was no correlation between driving performance and neuropsychological test results or ESS Score. Neuropsychological test results did not significantly change in the follow-up. The difficulties encountered by the narcolepsy patient in remaining alert may account for sleep-related motor vehicle accidents. Driving simulator investigations are closely related to real traffic situations than isolated neuropsychological tests. At the present time the driving simulator seems to be a useful instrument judging driving ability especially in cases with ambiguous neuropsychological results.

  20. Analysis of cohesion and collective efficacy profiles for the performance of soccer players.

    Science.gov (United States)

    Leo, Francisco M; Sánchez-Miguel, Pedro A; Sánchez-Oliva, David; Amado, Diana; García-Calvo, Tomás

    2013-12-18

    The principal aims of the study were to define different profiles of cohesion and perceived efficacy in soccer players and to measure their differences in performance. The subjects were 235 soccer players in the under-18 category who played in the National League in Spain and 15 coaches whose ages ranged from 29 to 45 years. Diverse instruments to assess cohesion, perceived efficacy, and expectations of success were used in the study. Moreover, we measured playing time and performance. The results of the study proved the existence of four cohesion and efficacy profiles that presented significant differences in expectations of success, playing time, and performance. Furthermore, significant differences were found in the distribution of players in the teams as a function of performance. The main conclusion of this study is that soccer players with higher cohesion and collective efficacy levels belonged to teams that completed the season at the top-level classification. In contrast, athletes with low cohesion and collective efficacy usually played in unsuccessful teams. Coaches and sports psychologists are encouraged to promote both social and task cohesion and collective efficacy to enhance team performance.

  1. Review of recycling performance indicators: A study on collection rate in Taiwan

    International Nuclear Information System (INIS)

    Wen Lihchyi; Lin Chunhsu; Lee, Soo-cheol

    2009-01-01

    The Taiwan Environmental Protection Administration (Taiwan EPA) launched a national Extended Producer Responsibility (EPR) system after integrating eight private recycling organizations in 1998. After that, the environmental performance of the EPR system brought a lot of attention to policy makers. Many studies show positive environmental effects of the EPR system in Taiwan. However, there are controversial questions remained, such as whether the performance indicators used are the right choice to estimate the environmental effects of the recycling policy? Can those estimated results really reflect the performance of the system? This paper would therefore like to more accurately evaluate the performance indicators of the EPR system based on data observed over the past decade in Taiwan. In the process of evaluating the performance indicators, we have found that the collection rates for durable goods are often ignored in countries that pursue a zero waste policy. This may affect the actual recycling outcome and resource direction targeted by producers. However, in order for the collection rate to be adopted as a policy indicator, how to estimate the amounts of retired or waste products during a period is critical. In this paper, we estimate the collection rate for electrical and electronic waste by using the survival analysis and ownership data analysis approaches. We also provide a comparison of both approaches and put forward suggestions for directions in the future in solid waste management.

  2. Review of recycling performance indicators: a study on collection rate in Taiwan.

    Science.gov (United States)

    Wen, Lihchyi; Lin, Chun-Hsu; Lee, Soo-Cheol

    2009-08-01

    The Taiwan Environmental Protection Administration (Taiwan EPA) launched a national Extended Producer Responsibility (EPR) system after integrating eight private recycling organizations in 1998. After that, the environmental performance of the EPR system brought a lot of attention to policy makers. Many studies show positive environmental effects of the EPR system in Taiwan. However, there are controversial questions remained, such as whether the performance indicators used are the right choice to estimate the environmental effects of the recycling policy? Can those estimated results really reflect the performance of the system? This paper would therefore like to more accurately evaluate the performance indicators of the EPR system based on data observed over the past decade in Taiwan. In the process of evaluating the performance indicators, we have found that the collection rates for durable goods are often ignored in countries that pursue a zero waste policy. This may affect the actual recycling outcome and resource direction targeted by producers. However, in order for the collection rate to be adopted as a policy indicator, how to estimate the amounts of retired or waste products during a period is critical. In this paper, we estimate the collection rate for electrical and electronic waste by using the survival analysis and ownership data analysis approaches. We also provide a comparison of both approaches and put forward suggestions for directions in the future in solid waste management.

  3. Rheological Method for Alpha Test Evaluation of Developing Superplasticizers’ Performance: Channel Flow Test

    Directory of Open Access Journals (Sweden)

    Jae Hong Kim

    2017-01-01

    Full Text Available Advance in high-range water-reducing admixture revolutionizes the workability and constructability of conventional vibrated concrete as well as self-consolidating concrete. Its need from construction fields has increased, and consequently a variety of new-type polycarboxylates, base polymers for the admixture, are being formulated in these days. Synthesizing new polymers needs a quick, but reliable, test to evaluate its performance on concrete. The test is also asked for selecting the best applicable brand of them before a test concrete will be mixed. This paper proposes a “channel flow test” and its usage for the purpose. The proposed procedure for the test includes the mix proportion of a test mortar, the test method, and rheological interpretation of the test results.

  4. Maximizing the performance of a multiple-stage variable-throat venturi scrubber for particle collection

    Science.gov (United States)

    Muir, D. M.; Akeredolu, F.

    The high collection efficiencies that are required nowadays to meet the stricter pollution control standards necessitate the use of high-energy scrubbers, such as the venturi scrubber, for the arrestment of fine particulate matter from exhaust gas streams. To achieve more energy-efficient particle collection, several venturi stages may be used in series. This paper is principally a theoretical investigation of the performance of a multiple-stage venturi scrubber, the main objective of the study being to establish the best venturi design configuration for any given set of operating conditions. A mathematical model is used to predict collection efficiency vs pressure drop relationships for particle sizes in the range 0.2-5.0 μm for one-, two-, three- and four-stage scrubbers. The theoretical predictions are borne out qualitatively by experimental work. The paper shows that the three-stage venturi produces the highest collection efficiencies over the normal operating range except for the collection of very fine particles at low pressure drops, when the single-stage venturi is best. The significant improvement in performance achieved by the three-stage venturi when compared with conventional single-stage operation increases as both the particle size and system pressure drop increase.

  5. A LABORATORY TEST FOR THE EXAMINATION OF ALACTIC RUNNING PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Armin Kibele

    2005-12-01

    Full Text Available A new testing procedure is introduced to evaluate the alactic running performance in a 10s sprint task with near-maximal movement velocity. The test is performed on a motor-equipped treadmill with inverted polarity that increases mechanical resistance instead of driving the treadmill belt. As a result, a horizontal force has to be exerted against the treadmill surface in order to overcome the resistant force of the engine and to move the surface in a backward direction. For this task, subjects lean with their hands towards the front safety barrier of the treadmill railing with a slightly inclined body posture. The required skill resembles the pushing movement of bobsleigh pilots at the start of a race. Subjects are asked to overcome this mechanical resistance and to cover as much distance as possible within a time period of 10 seconds. Fifteen male students (age: 27.7 ± 4.1 years, body height: 1.82 ± 0.46 m, body mass: 78.3 ± 6.7 kg participated in a study. As the resistance force was set to 134 N, subjects ran 35.4 ± 2.6 m on the average corresponding to a mean running velocity of 3.52 ± 0.25 m·s-1. The validity of the new test was examined by statistical inference with various measures related to alactic performance including a metabolic equivalent to estimate alactic capacity (2892 ± 525 mL O2, an estimate for the oxygen debt (2662 ± 315 ml, the step test by Margaria to estimate alactic energy flow (1691 ± 171 W, and a test to measure the maximal strength in the leg extensor muscles (2304 ± 351 N. The statistical evaluation showed that the new test is in good agreement with the theoretical assumptions for alactic performance. Significant correlation coefficients were found between the test criteria and the measures for alactic capacity (r = 0.79, p < 0.01 as well as alactic power (r = 0.77, p < 0.01. The testing procedure is easy to administer and it is best suited to evaluate the alactic capacity for bobsleigh pilots as well as for

  6. Performance of CREAM Calorimeter Results of Beam Tests

    CERN Document Server

    Ahn, H S; Beatty, J J; Bigongiari, G; Castellina, A; Childers, J T; Conklin, N B; Coutu, S; Duvernois, M A; Ganel, O; Han, J H; Hyun, H J; Kang, T G; Kim, H J; Kim, K C; Kim, M Y; Kim, T; Kim, Y J; Lee, J K; Lee, M H; Lutz, L; Maestro, P; Malinine, A; Marrocchesi, P S; Mognet, S I; Nam, S W; Nutter, S; Park, N H; Park, H; Seo, E S; Sina, R; Syed, S; Song, C; Swordy, S; Wu, J; Yang, J; Zhang, H Q; Zei, R; Zinn, S Y

    2005-01-01

    The Cosmic Ray Energetics And Mass (CREAM), a balloon-borne experiment, is under preparation for a flight in Antarctica at the end of 2004. CREAM is planned to measure the energy spectrum and composition of cosmic rays directly at energies between 1 TeV and 1000 TeV. Incident particle energies will be measured by a transition radiation detector and a sampling calorimeter. The calorimeter was constructed at the University of Maryland and tested at CERN in 2003. Performance of the calorimeter during the beam tests is reported.

  7. Thermal performance test for steam turbine of nuclear power plants

    International Nuclear Information System (INIS)

    Bu Yubing; Xu Zongfu; Wang Shiyong

    2014-01-01

    Through study of steam turbine thermal performance test of CPR1000 nuclear power plant, we solve the enthalpy calculation problems of the steam turbine in wet steam zone using heat balance method which can help to figure out the real overall heat balance diagram for the first time, and we develop a useful software for thermal heat balance calculation. Ling'ao phase II as an example, this paper includes test instrument layout, system isolation, risk control, data acquisition, wetness measurement, heat balance calculation, etc. (authors)

  8. Reliability performance of standby equipment with periodic testing

    International Nuclear Information System (INIS)

    Sim, S.H.

    1985-11-01

    In this report, the reliability performance of standby equipment subjected to periodic testing is studied. analytical expressions have been derived for reliability measures, such as the man accumulated operating time to failure, the expected number of tests between two consecutive failures, the mean time to failure following an emergency start-up and the probability of failing to complete an emergency mission of a specified duration. These results are useful for the reliability assessment of standby equipment such as combustion turbine units of the emergency power supply system, and of the Class III power system at a nuclear generating station

  9. Acceptability of self-collected versus provider-collected sampling for HPV DNA testing among women in rural El Salvador.

    Science.gov (United States)

    Rosenbaum, Alan J; Gage, Julia C; Alfaro, Karla M; Ditzian, Lauren R; Maza, Mauricio; Scarinci, Isabel C; Felix, Juan C; Castle, Philip E; Villalta, Sofia; Miranda, Esmeralda; Cremer, Miriam L

    2014-08-01

    To determine the acceptability of self-collected versus provider-collected sampling among women participating in public sector HPV-based cervical cancer screening in El Salvador. Two thousand women aged 30-49 years underwent self-collected and provider-collected sampling with careHPV between October 2012 and March 2013 (Qiagen, Gaithersburg, MD, USA). After sample collection, a random sample of women (n=518) were asked about their experience. Participants were questioned regarding sampling method preference, previous cervical cancer screening, HPV and cervical cancer knowledge, HPV risk factors, and demographic information. All 518 women approached to participate in this questionnaire study agreed and were enrolled, 27.8% (142 of 511 responding) of whom had not received cervical cancer screening within the past 3 years and were considered under-screened. Overall, 38.8% (n=201) preferred self-collection and 31.9% (n=165) preferred provider collection. Self-collection preference was associated with prior tubal ligation, HPV knowledge, future self-sampling preference, and future home-screening preference (P<0.05). Reasons for self-collection preference included privacy/embarrassment, ease, and less pain; reasons cited for provider-collection preference were result accuracy and provider knowledge/experience. Self-sampling was found to be acceptable, therefore screening programs could consider offering this option either in the clinic or at home. Self-sampling at home may increase coverage in low-resource countries and reduce the burden that screening places upon clinical infrastructure. Copyright © 2014 International Federation of Gynecology and Obstetrics. All rights reserved.

  10. Results of tritium tests performed on Sandia Laboratories decontamination system

    International Nuclear Information System (INIS)

    Gildea, P.D.; Wall, W.R.; Gede, V.P.

    1978-05-01

    The Tritium Research Laboratory (TRL), a facility for performing experiments using gram amounts of tritium, became operational on October 1, 1977. As secondary containment, the TRL employs sealed glove boxes connected on demand to two central decontamination systems, the Gas Purification System and the Vacuum Effluent Recovery System. Performance tests on these systems show the tritium removal systems can achieve concentration reduction factors (ratio of inlet to exhaust concentrations) much in excess of 1000 per pass at inlet concentrations of 1 part per million or less for both tritium and tritiated methane

  11. Can trained lay providers perform HIV testing services? A review of national HIV testing policies.

    Science.gov (United States)

    Flynn, David E; Johnson, Cheryl; Sands, Anita; Wong, Vincent; Figueroa, Carmen; Baggaley, Rachel

    2017-01-04

    Only an estimated 54% of people living with HIV are aware of their status. Despite progress scaling up HIV testing services (HTS), a testing gap remains. Delivery of HTS by lay providers may help close this testing gap, while also increasing uptake and acceptability of HIV testing among key populations and other priority groups. 50 National HIV testing policies were collated from WHO country intelligence databases, contacts and testing program websites. Data regarding lay provider use for HTS was extracted and collated. Our search had no geographical or language restrictions. This data was then compared with reported data from the Global AIDS Response Progress Reporting (GARPR) from July 2015. Forty-two percent of countries permit lay providers to perform HIV testing and 56% permit lay providers to administer pre-and post-test counseling. Comparative analysis with GARPR found that less than half (46%) of reported data from countries were consistent with their corresponding national HIV testing policy. Given the low uptake of lay provider use globally and their proven use in increasing HIV testing, countries should consider revising policies to support lay provider testing using rapid diagnostic tests.

  12. Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

    Energy Technology Data Exchange (ETDEWEB)

    Fuehne, David Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lattin, Rebecca Renee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-28

    The Rad-NESHAP program, part of the Air Quality Compliance team of LANL’s Compliance Programs group (EPC-CP), and the Radiation Instrumentation & Calibration team, part of the Radiation Protection Services group (RP-SVS), frequently partner on issues relating to characterizing air flow streams. This memo documents the most recent example of this partnership, involving performance testing of sulfur hexafluoride detectors for use in stack gas mixing tests. Additionally, members of the Rad-NESHAP program performed a functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument. Prior to commissioning a new stack sampling system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniformity of tracer gas and aerosol mixing in the air stream. For these mix tests, tracer media (sulfur hexafluoride gas or liquid oil aerosol particles) are injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of these media concentrations must be under 20% when evaluated over the central 2/3 area of the stack or duct. The instruments which measure these air concentrations must be tested prior to the stack tests in order to ensure their linear response to varying air concentrations of either tracer gas or tracer aerosol. The instruments used in tracer gas and aerosol mix testing cannot be calibrated by the LANL Standards and Calibration Laboratory, so they would normally be sent off-site for factory calibration by the vendor. Operational requirements can prevent formal factory calibration of some instruments after they have been used in hazardous settings, e.g., within a radiological facility with potential airborne contamination. The performance tests described in this document are intended to demonstrate the reliable

  13. Historical estimates of external gamma exposure and collective external gamma exposure from testing at the Nevada Test Site. I. Test series through HARDTACK II, 1958

    Energy Technology Data Exchange (ETDEWEB)

    Anspaugh, L.R.; Church, B.W.

    1985-12-01

    In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, Utah; Ely, Nevada; and Las Vegas, Nevada. Three events, HARRY (May 19, 1953), BEE (March 22, 1955), and SMOKY (August 31, 1957), accounted for over half of the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of ''infinite exposure,'' ''estimated exposure,'' and ''one year effective biological exposure'' are explained. 4 figs., 7 tabs.

  14. Historical estimates of external gamma exposure and collective external gamma exposure from testing at the Nevada Test Site. I. Test series through HARDTACK II, 1958

    International Nuclear Information System (INIS)

    Anspaugh, L.R.; Church, B.W.

    1986-01-01

    In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, UT; Ely, NV; and Las Vegas, NV. Three events, HARRY (19 May 1953), BEE (22 March 1955), and SMOKY (31 August 1957), accounted for more than half the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of infinite exposure, estimated exposure, and 1-yr effective biological exposure are explained

  15. Historical estimates of external gamma exposure and collective external gamma exposure from testing at the Nevada Test Site. I. Test series through HARDTACK II, 1958

    International Nuclear Information System (INIS)

    Anspaugh, L.R.; Church, B.W.

    1985-12-01

    In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, Utah; Ely, Nevada; and Las Vegas, Nevada. Three events, HARRY (May 19, 1953), BEE (March 22, 1955), and SMOKY (August 31, 1957), accounted for over half of the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of ''infinite exposure,'' ''estimated exposure,'' and ''one year effective biological exposure'' are explained. 4 figs., 7 tabs

  16. Recycle Waste Collection Tank (RWCT) simulant testing in the PVTD feed preparation system

    International Nuclear Information System (INIS)

    Abrigo, G.P.; Daume, J.T.; Halstead, S.D.; Myers, R.L.; Beckette, M.R.; Freeman, C.J.; Hatchell, B.K.

    1996-03-01

    (This is part of the radwaste vitrification program at Hanford.) RWCT was to routinely receive final canister decontamination sand blast frit and rinse water, Decontamination Waste Treatment Tank bottoms, and melter off-gas Submerged Bed Scrubber filter cake. In order to address the design needs of the RWCT system to meet performance levels, the PNL Vitrification Technology (PVTD) program used the Feed Preparation Test System (FPTS) to evaluate its equipment and performance for a simulant of RWCT slurry. (FPTS is an adaptation of the Defense Waste Processing Facility feed preparation system and represents the initially proposed Hanford Waste Vitrification Plant feed preparation system designed by Fluor-Daniel, Inc.) The following were determined: mixing performance, pump priming, pump performance, simulant flow characterization, evaporator and condenser performance, and ammonia dispersion. The RWCT test had two runs, one with and one without tank baffles

  17. Science Library of Test Items. Volume Twenty-One. A Collection of Multiple Choice Test Items Relating Mainly to Physics, 2.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…

  18. Performance testing of 3D point cloud software

    Science.gov (United States)

    Varela-González, M.; González-Jorge, H.; Riveiro, B.; Arias, P.

    2013-10-01

    LiDAR systems are being used widely in recent years for many applications in the engineering field: civil engineering, cultural heritage, mining, industry and environmental engineering. One of the most important limitations of this technology is the large computational requirements involved in data processing, especially for large mobile LiDAR datasets. Several software solutions for data managing are available in the market, including open source suites, however, users often unknown methodologies to verify their performance properly. In this work a methodology for LiDAR software performance testing is presented and four different suites are studied: QT Modeler, VR Mesh, AutoCAD 3D Civil and the Point Cloud Library running in software developed at the University of Vigo (SITEGI). The software based on the Point Cloud Library shows better results in the loading time of the point clouds and CPU usage. However, it is not as strong as commercial suites in working set and commit size tests.

  19. Reliability data collection on IC and VLSI devices tested under accelerated life conditions

    International Nuclear Information System (INIS)

    Barry, D.M.; Meniconi, M.

    1986-01-01

    As part of a more general investigation into the reliability and failure causes of semiconductor devices, statistical samples of integrated circuit devices (LM741C) and dynamic random access memory devices (TMS4116) were tested destructively to failure using elevated temperature as the accelerating stress. The devices were operated during the life test and the failure data generated were collected automatically using a multiple question-and-answer program and a process control computer. The failure data were modelled from the lognormal, inverse Gaussian and Weibull distribution using an Arrhenius reaction rate model. The failed devices were later decapsulated for failure cause determination. (orig./DG)

  20. Test Operations Procedure (TOP) 1-1-062 Environmental Effects Data Collection

    Science.gov (United States)

    2008-09-12

    this procedure. 11. ESTIMATION DESCRIPTION The prime example of an empirically based model is the Universal Soil Loss Equation ( USLE ) developed...impacts to human health and welfare and to the natural environment. The type of data collected might include noise levels, soil erosion, and...uptake relevant to flora/fauna and the soil erosion effects of proposed testing. c. Plan to identify any modifications/alternatives implemented

  1. Performance tests of a special ionization chamber for X-rays in mammography energy range

    Energy Technology Data Exchange (ETDEWEB)

    Silva, J.O., E-mail: jonas.silva@ufg.br [Universidade Federal de Goiás (UFG), Goiânia (Brazil). Instituto de Física; Caldas, L.V.E. [Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP), São Paulo, SP (Brazil). Centro de Metrologia das Radiações

    2017-07-01

    A special mammography homemade ionization chamber was developed to be applied for mammography energy range dosimetry. This chamber has a total sensitive volume of 6 cm{sup 3} and is made of a PMMA body and graphite coated collecting electrode. Performance tests as saturation, ion collection efficiency, linearity of chamber response versus air kerma rate and energy dependence were determined. The results obtained with this special homemade ionization chamber are within the limits stated in international recommendations. This chamber can be used in quality control programs of mammography energy range. All measurements were carried out at the Calibration Laboratory of IPEN. (author)

  2. Investigation of Concrete Electrical Resistivity As a Performance Based Test

    OpenAIRE

    Malakooti, Amir

    2017-01-01

    The purpose of this research project was to identify the extent that concrete resistivity measurements (bulk and/or surface) can be used as a performance based lab test to improve the quality of concrete in Utah bridge decks. By allowing UDOT to specify a required resistivity, concrete bridge deck quality will increase and future maintenance costs will decrease. This research consisted of two phases: the field phase and the lab phase. In the field phase, concrete samples were gathered from...

  3. Performance test of the CMS link alignment system

    CERN Document Server

    Arce, P; Calvo, E; Fernández, M G; Ferrando, A; Figueroa, C F; García, N; Josa-Mutuberria, I; Molinero, A; Oller, J C; Rodrigo, T; Vila, I; Virto, A L

    2002-01-01

    A first global test of the CMS Alignment System was performed at the I4 hall of the CERN ISR tunnel. Positions of the network, reproducing a set of points in the CMS detector monitored by the Link System, were reconstructed and compared to survey measurements. Spatial and angular reconstruction precisions reached in the present experimental set-up are already close to the CMS requirements.

  4. Development of Testing Methodologies to Evaluate Postflight Locomotor Performance

    Science.gov (United States)

    Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Richards, J. T.; Miller, C. A.; Brady, R.; Warren, L. E.; Bloomberg, J. J.

    2006-01-01

    Crewmembers experience locomotor and postural instabilities during ambulation on Earth following their return from space flight. Gait training programs designed to facilitate recovery of locomotor function following a transition to a gravitational environment need to be accompanied by relevant assessment methodologies to evaluate their efficacy. The goal of this paper is to demonstrate the operational validity of two tests of locomotor function that were used to evaluate performance after long duration space flight missions on the International Space Station (ISS).

  5. Testing the performance of a blind burst statistic

    Energy Technology Data Exchange (ETDEWEB)

    Vicere, A [Istituto di Fisica, Universita di Urbino (Italy); Calamai, G [Istituto Nazionale di Fisica Nucleare, Sez. Firenze/Urbino (Italy); Campagna, E [Istituto Nazionale di Fisica Nucleare, Sez. Firenze/Urbino (Italy); Conforto, G [Istituto di Fisica, Universita di Urbino (Italy); Cuoco, E [Istituto Nazionale di Fisica Nucleare, Sez. Firenze/Urbino (Italy); Dominici, P [Istituto di Fisica, Universita di Urbino (Italy); Fiori, I [Istituto di Fisica, Universita di Urbino (Italy); Guidi, G M [Istituto di Fisica, Universita di Urbino (Italy); Losurdo, G [Istituto Nazionale di Fisica Nucleare, Sez. Firenze/Urbino (Italy); Martelli, F [Istituto di Fisica, Universita di Urbino (Italy); Mazzoni, M [Istituto Nazionale di Fisica Nucleare, Sez. Firenze/Urbino (Italy); Perniola, B [Istituto di Fisica, Universita di Urbino (Italy); Stanga, R [Istituto Nazionale di Fisica Nucleare, Sez. Firenze/Urbino (Italy); Vetrano, F [Istituto di Fisica, Universita di Urbino (Italy)

    2003-09-07

    In this work, we estimate the performance of a method for the detection of burst events in the data produced by interferometric gravitational wave detectors. We compute the receiver operating characteristics in the specific case of a simulated noise having the spectral density expected for Virgo, using test signals taken from a library of possible waveforms emitted during the collapse of the core of type II supernovae.

  6. Achievement test performance in children conceived by IVF.

    Science.gov (United States)

    Mains, L; Zimmerman, M; Blaine, J; Stegmann, B; Sparks, A; Ansley, T; Van Voorhis, B

    2010-10-01

    Long-term follow-up studies of children conceived by IVF are limited. We examine academic performance on standardized tests [Iowa Tests of Basic Skills/Educational Development (ITBS/ITED)] of children conceived by IVF. Parents of children 8-17 years of age at the onset of the study (March 2008) who were conceived by IVF at the University of Iowa Hospitals and Clinics and living in the state of Iowa were contacted by mail. Parents completed questionnaires on their child's health and education and parental education. ITBS/ITED scores from school grades 3-12 were obtained on IVF children and a group of anonymous children matched by grade, year, gender and school district. Scores were analyzed using linear mixed models. Four hundred and ninety-seven couples were contacted. Two hundred and ninety-five couples (463 children) agreed to participate (59.4% of parents), with ITBS/ITED scores available on 423 children (91.4% of participants). IVF children scored higher than the national mean (P divorce and child's BMI. Cryopreservation, length of embryo culture and method of insemination did not affect scores. IVF children scored higher on standardized tests than their matched peers, suggesting that IVF does not have a negative effect on cognitive development. However, long-term follow-up of IVF children is still limited. Further research should be performed on the effect of multiple gestation on academic performance.

  7. Results of performance tests on polymer zirconium compound (PZC)

    International Nuclear Information System (INIS)

    Sombrito, Elvira Z.; Bulos, Adelina DM.

    2006-01-01

    Three batches of polyzirconium compound (PZC) consisting of nine samples were tested for its application as column material for adsorbing reactor-produced molybdenum-99 ( 99 Mo). Using low specific activity molybdenum solution (∼500 μCi/267 mg Mo), the adsorption capacity, elution yield, elution volume and molybdenum breakthrough were measured. The average adsorption capacity of the nine samples is 239 ± 17 mg Mo/g PZC. The elution yield values obtained are lower than previously obtained and averaged at 47% with 30% variability. Molybdenum breakthrough also exceeded the limits for 99m Tc eluates. Considering the better performance of 2002 PZC samples, the samples may have undergone some changes during storage (tests were performed in December 2003) and/or the adsorption process did not conform to the recommended procedure. If this were the case, it demonstrated the importance of strictly following the recommended protocol. Relative values showed that the last two batches (PZC 030718 and PC 030726) performed better than the first batch in terms of elution yield and elution profile. These two batches exhibited amorphous structure as seen by x-ray diffraction analysis of the PZC test samples. (author)

  8. Test Program for the Performance Analysis of DNS64 Servers

    Directory of Open Access Journals (Sweden)

    Gábor Lencse

    2015-09-01

    Full Text Available In our earlier research papers, bash shell scripts using the host Linux command were applied for testing the performance and stability of different DNS64 server imple­mentations. Because of their inefficiency, a small multi-threaded C/C++ program (named dns64perf was written which can directly send DNS AAAA record queries. After the introduction to the essential theoretical background about the structure of DNS messages and TCP/IP socket interface programming, the design decisions and implementation details of our DNS64 performance test program are disclosed. The efficiency of dns64perf is compared to that of the old method using bash shell scripts. The result is convincing: dns64perf can send at least 95 times more DNS AAAA record queries per second. The source code of dns64perf is published under the GNU GPLv3 license to support the work of other researchers in the field of testing the performance of DNS64 servers.

  9. Fuel leak testing performance at NPP Jaslovske Bohunice

    International Nuclear Information System (INIS)

    Slugen, V.; Krnac, S.; Smiesko, I.

    1995-01-01

    The NPP Bohunice VVER-440 fuel leak testing experience are relatively extensive in comparison with other VVER-440 users. As the first Europe NPP was adapted Siemens (KWU) in core-sipping equipment to VVER-440 units and since this time were have done these tests also for NPP Paks (Hungary) and NPP Dukovany (Czech Republic). The occurrence of leaking fuel assemblies in NPP is in the last 5 years relatively stabilised and low. A significant difference can be observed between type V-230 (31 leaks) and type V-213 (1 leak). None of of the indicated leaking fuel assemblies has been investigated in the hot cell. Therefore cannot be confirm the effective causes of leak occurrence. Nevertheless, the fuel failure rate and the performance of leak testing in NPP Bohunice are comparable to the world standard at PWR's. 1 tab., 2 figs., 3 refs

  10. Fuel leak testing performance at NPP Jaslovske Bohunice

    Energy Technology Data Exchange (ETDEWEB)

    Slugen, V; Krnac, S [Slovak Technical Univ., Bratislava (Slovakia); Smiesko, I [Nuclear Powr Plant EBO, Jaslovske Bohuce (Slovakia)

    1996-12-31

    The NPP Bohunice VVER-440 fuel leak testing experience are relatively extensive in comparison with other VVER-440 users. As the first Europe NPP was adapted Siemens (KWU) in core-sipping equipment to VVER-440 units and since this time were have done these tests also for NPP Paks (Hungary) and NPP Dukovany (Czech Republic). The occurrence of leaking fuel assemblies in NPP is in the last 5 years relatively stabilised and low. A significant difference can be observed between type V-230 (31 leaks) and type V-213 (1 leak). None of of the indicated leaking fuel assemblies has been investigated in the hot cell. Therefore cannot be confirm the effective causes of leak occurrence. Nevertheless, the fuel failure rate and the performance of leak testing in NPP Bohunice are comparable to the world standard at PWR`s. 1 tab., 2 figs., 3 refs.

  11. Can the Immune System Perform a t-Test?

    Science.gov (United States)

    Faria, Bruno Filipe; Mostardinha, Patricia

    2017-01-01

    The self-nonself discrimination hypothesis remains a landmark concept in immunology. It proposes that tolerance breaks down in the presence of nonself antigens. In strike contrast, in statistics, occurrence of nonself elements in a sample (i.e., outliers) is not obligatory to violate the null hypothesis. Very often, what is crucial is the combination of (self) elements in a sample. The two views on how to detect a change seem challengingly different and it could seem difficult to conceive how immunological cellular interactions could trigger responses with a precision comparable to some statistical tests. Here it is shown that frustrated cellular interactions reconcile the two views within a plausible immunological setting. It is proposed that the adaptive immune system can be promptly activated either when nonself ligands are detected or self-ligands occur in abnormal combinations. In particular we show that cellular populations behaving in this way could perform location statistical tests, with performances comparable to t or KS tests, or even more general data mining tests such as support vector machines or random forests. In more general terms, this work claims that plausible immunological models should provide accurate detection mechanisms for host protection and, furthermore, that investigation on mechanisms leading to improved detection in “in silico” models can help unveil how the real immune system works. PMID:28046042

  12. Small-scale tunnel test for blast performance

    International Nuclear Information System (INIS)

    Felts, J E; Lee, R J

    2014-01-01

    The data reported here provide a validation of a small-scale tunnel test as a tool to guide the optimization of new explosives for blast performance in tunnels. The small-scale arrangement consisted of a 2-g booster and 10-g sample mounted at the closed end of a 127 mm diameter by 4.6-m long steel tube with pressure transducers along its length. The three performance characteristics considered were peak pressure, initial energy release, and impulse. The relative performance from five explosives was compared to that from a 1.16-m diameter by 30-m long tunnel that used 2.27-kg samples. The peak pressure values didn't correlate between the tunnels. Partial impulse for the explosives did rank similarly. The initial energy release was determined from a one-dimensional point-source analysis, which nearly tracked with impulse suggesting additional energy released further down the tunnel for some explosives. This test is a viable tool for optimizing compositional variations for blast performance in target scenarios of similar geometry.

  13. Performance measurements at the fast flux test facility

    International Nuclear Information System (INIS)

    Baumhardt, R.J.; Newland, D.J.; Praetorius, P.R.

    1987-01-01

    In 1984, Fast Flux Test Facility (FFTF) management recognized the need to develop a measurement system that would quantify the operational performance of the FFTF and the human resources needed to operate it. Driven by declining budgets and the need to safely manage a manpower rampdown at FFTF, an early warning system was developed. Although the initiating event for the early warning system was the need to safely manage a manpower rampdown, many related uses have evolved. The initial desired objective for the FFTF performance measurements was to ensure safety and control of key performance trends. However, the early warning system has provided a more quantitative, supportable basis upon which to make decisions. From this initial narrow focus, efforts in the FFTF plant and supporting organizations are leading to measurement of and, subsequently, improvements in productivity. Pilot projects utilizing statistical process control have started with longer range productivity improvement

  14. Pilot test of ANSI draft standard N13.29 environmental dosimetry -- Performance criteria for testing

    International Nuclear Information System (INIS)

    Klemic, G.; Shebell, P.; Monetti, M.; Raccah, F.; Sengupta, S.

    1998-09-01

    American National Standards Institute Draft N13.29 describes performance tests for environmental radiation dosimetry providers. If approved it would be the first step toward applying the types of performance testing now required in personnel dosimetry to environmental radiation monitoring. The objective of this study was to pilot test the draft standard, before it undergoes final balloting, on a small group of dosimetry providers that were selected to provide a mix of facility types, thermoluminescent dosimeter designs and monitoring program applications. The first phase of the pilot test involved exposing dosimeters to laboratory photon, beta, and x-ray sources at routine and accident dose levels. In the second phase, dosimeters were subjected to ninety days of simulated environmental conditions in an environmental chamber that cycled through extremes of temperature and humidity. Two out of seven participants passed all categories of the laboratory testing phase, and all seven passed the environmental test phase. While some relatively minor deficiencies were uncovered in the course of the pilot test, the results show that draft N13.29 describes useful tests that could be appropriate for environmental dosimetry providers. An appendix to this report contains recommendations that should be addressed by the N13.29 working group before draft N13.29 is submitted for balloting

  15. Addendum to ''Test Plan: Small-Scale Seal Performance Tests (SSSPT)''

    International Nuclear Information System (INIS)

    Finley, R.E.

    1992-01-01

    This document describes activities that are intended to update the data base of fluid flow measurements made on expansive salt concrete (ESC) seals as part of the Small-Scale Seal Performance Tests (SSSPT). The original plans for the SSSPT experiments are described by Stormont (1985a and 1985b). These seals have previously been tested with brine and gas during the early stages (less than 450 days) after emplacement. The purpose of this Test Plan Addendum is to detail the activities necessary to, update the gas and brine measurements previously performed on the SSSPT Series A and Series B seals and to identify the key personnel responsible for implementing these activities. This addendum describes a limited undertaking and does NOT change the scope of the original test plan

  16. Carbohydrate ingestion improves performance of a new reliable test of soccer performance.

    Science.gov (United States)

    Currell, Kevin; Conway, Steve; Jeukendrup, Asker E

    2009-02-01

    The aim of the study was to investigate the reliability of a new test of soccer performance and evaluate the effect of carbohydrate (CHO) on soccer performance. Eleven university footballers were recruited and underwent 3 trials in a randomized order. Two of the trials involved ingesting a placebo beverage, and the other, a 7.5% maltodextrin solution. The protocol comprised a series of ten 6-min exercise blocks on an outdoor Astroturf pitch, separated by the performance of 2 of the 4 soccer-specific tests, making the protocol 90 min in duration. The intensity of the exercise was designed to be similar to the typical activity pattern during soccer match play. Participants performed skill tests of dribbling, agility, heading, and shooting throughout the protocol. The coefficients of variation for dribbling, agility, heading, and shooting were 2.2%, 1.2%, 7.0%, and 2.8%, respectively. The mean combined placebo scores were 42.4 +/- 2.7 s, 43.1 +/- 3.7 s, 210 +/- 34 cm, and 212 +/- 17 points for agility, dribbling, heading, and kicking, respectively. CHO ingestion led to a combined agility time of 41.5 +/- 0.8 s, for dribbling 41.7 +/- 3.5 s, 213 +/- 11 cm for heading, and 220 +/- 5 points for kicking accuracy. There was a significant improvement in performance for dribbling, agility, and shooting (p soccer performance, and ingesting CHO leads to an improvement in soccer performance.

  17. The influence of data collection rate, containment size and data smoothing on containment Integrated Leak Rate Tests

    International Nuclear Information System (INIS)

    Wagner, W.T.; Langan, J.P.; Norris, W.E.; Lurie, D.

    1988-01-01

    Phase I of a U.S. Nuclear Regulatory Commission contract investigated nuclear power plant Integrated Leak Rate Tests (ILRTs) using data gathered at many domestic and foreign ILRTs. The study evaluated ILRTs with the ANS criteria (in ANSI/ANS-56.8-1987) and the proposed extended ANS criteria (in draft Regulatory Guide, Task MS 021-5, October 1986). The study considered (1) the effects of data collection rates on ILRT conclusions, (2) a possible relationship between containment size, data collection rate and ILRT duration, (3) the impact of the proposed extended ANS methodology on ILRTs, and (4) the influence of data smoothing on ILRT data. The study was performed using 20 sets of Type A and 17 sets of verification data

  18. Retrospective evaluation of unexpected events during collection of blood donations performed with and without sedation in cats (2010-2013).

    Science.gov (United States)

    Doolin, Kerry S; Chan, Daniel L; Adamantos, Sophie; Humm, Karen

    2017-09-01

    Describe unexpected events (UEs) that occurred during blood donation in cats with and without sedation. Retrospective observational study (2010-2013). University teaching hospital. Client-owned healthy cats enrolled in a blood donation program. None. Blood collection for transfusion was performed 115 times from 32 cats. Seventy donation events were in unsedated cats and 45 in sedated cats. For each collection, the anticipated blood volume to be collected, actual blood volume collected, sedation protocol, and any UE in the peridonation period were recorded. There were 6 categories of UEs: movement during donation, donor anxiety, inadequate collected blood volume, jugular vessel related UEs, additional sedation requirement, and cardiorespiratory distress. Fisher's exact test was used to compare the frequency of UEs between sedated and unsedated cats. UEs were recorded in 54 of 115 collections. In the donor population, movement was reported as an UE in 0 cats that donated under sedation and 24/70 (34.3%) cats that donated without sedation (P donated under sedation and 14/70 (20.0%) cats that donated unsedated (P = 0.014). Unsedated donation did not increase the likelihood of inadequate donation volume, jugular vessel related UEs, or cardiorespiratory distress. Eight of 45 (17.8%) sedated donations required additional sedation. Movement during donation and signs of donor anxiety were more frequent in unsedated cats. These were considered minor issues, expected in unsedated cats being gently restrained. Blood collection from unsedated feline donors is a viable alternative to sedated donation. © Veterinary Emergency and Critical Care Society 2017.

  19. Testing of tactical performance in youth elite soccer.

    Science.gov (United States)

    Memmert, Daniel

    2010-01-01

    This is a twofold study with the goals of evaluating tactical oriented game test situations for 12-13-year old highly-talented soccer players and to analyze dynamic, intra-individual developments of the players. A cross-sectional design was carried in study 1, using game test situations to measure specific tactics and creative performance for 195 expert players. The results from five evaluation criteria show that both diagnostic instruments can be used for recording football-specific creativity and game intelligence in talented young players. They produced tactical indicators that can be described as objective and valid, exhibit a sufficient degree of differentiation and are easy to record. Study 2 uses a longitudinal design to present a dynamic performance diagnostic tool for analyzing intra-individual improvements of German Soccer Foundation talents according to football-specific creativity and game intelligence. The results with respect to divergent tactical thinking clearly show that very different change processes were observed in the German Soccer Foundation players. Finally, the practical implications for the training process are discussed on the basis of both studies. Key pointsWith game test situations it is possible to assess tactical performance as game intelligence and creativity objective, valid, with a sufficient degree of differentiation, and economically.The results with respect to game intelligence and creativity show that very different change processes were observed in the German Soccer Foundation players dependend on the bases (trainers).Current literature on tactics for school sports as well as for children's, youth and high performance soccer at the club level should place much more emphasis on individual and group-tactical requirements in soccer.

  20. Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Buttner, William J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hartmann, Kevin S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Schmidt, Kara [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cebolla, Rafeal O [Joint Research Centre, Petten, the Netherlands; Weidner, Eveline [Joint Research Centre, Petten, the Netherlands; Bonato, Christian [Joint Research Centre, Petten, the Netherlands

    2017-11-06

    Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of

  1. Performance test for prototype game for children with adhd

    Science.gov (United States)

    Bahana, R.; Gaol, F. L.; Wiguna, T.; Hendric, S. W. H. L.; Soewito, B.; Nugroho, E.; Dirgantoro, B. P.; Abdurachman, E.

    2018-03-01

    The gaming industry has become one of the fastest growing industries in the world. In recent years there have been several studies that have used games, especially computer-based ones to improve the executive function of children with Attention Deficit Hyperactivity Disorder (ADHD) especially in working memory improvements. There are still several obstacles in using computer-based games that have been circulating today in Indonesia. The aim of this research is to develop and create a prototype game that can be used to improve working memory of children with ADHD using Bahasa Indonesia. The prototype game application is a race game with matching colors and memory work tasks; developed using Construct2. Players will play as a driver, delivering certain fruits to specific homes with different colors. The game also included visuospatial tasks such as remembering the objects. For performance test, CPU utilization, average FPS and image memory usage has been tested in several browsers. In conclusion, the performance tests results show that the first type of the prototype game is good enough to be played in desktop or laptop.

  2. Calibration and performance testing of electronic personal dosimeters (EPD)

    International Nuclear Information System (INIS)

    Banaga, H.A.

    2008-04-01

    In modern radiation protection practices, active personal dosimeters are becoming absolutely necessary operational tools for satisfying the ALARA principle. The aim of this work was to carry out calibration and performance testing of ten electronic personal dosimeters (EPD) used for the individual monitoring. The EPDs were calibrated in terms of operation radiation protection quantity, personal dose equivalent, Hp (10). Calibrations were carried out at three of x-ray beam qualities described in ISO 4037 namely 60, 100 and 150 kV in addition to Cs-137 gamma ray quality. The calibrations were performed using polymethylmethacrylate (PMMA) phantom with dimensions 20*20*15 cm 3 . Conversion coefficient Hp (10)/K air for the phantom was also calculated. The response and linearity of the dosimeter at the specified energies were also tested. The EPDs tested showed that the calibration coefficient ranged from 0.60 to 1.31 and an equivalent response for the specified energies that ranged from 0.76 to 1.67. The study demonstrated the possibility of using non standard phantom for calibrating dosimeters used for individual monitoring. The dosimeters under study showed a good response in all energies except the response in quality 100 kV. The linearity of the dosimeters was within ±15%, with the exception of the quality 100 kV where this limit was exceeded.(Author)

  3. Performance verification tests of JT-60SA CS model coil

    Energy Technology Data Exchange (ETDEWEB)

    Obana, Tetsuhiro, E-mail: obana.tetsuhiro@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Murakami, Haruyuki [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan); Takahata, Kazuya; Hamaguchi, Shinji; Chikaraishi, Hirotaka; Mito, Toshiyuki; Imagawa, Shinsaku [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Kizu, Kaname; Natsume, Kyohei; Yoshida, Kiyoshi [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)

    2015-11-15

    Highlights: • The performance of the JT-60SA CS model coil was verified. • The CS model coil comprised a quad-pancake wound with a Nb{sub 3}Sn CIC conductor. • The CS model coil met the design requirements. - Abstract: As a final check of the coil manufacturing method of the JT-60 Super Advanced (JT-60SA) central solenoid (CS), we verified the performance of a CS model coil. The model coil comprised a quad-pancake wound with a Nb{sub 3}Sn cable-in-conduit conductor. Measurements of the critical current, joint resistance, pressure drop, and magnetic field were conducted in the verification tests. In the critical-current measurement, the critical current of the model coil coincided with the estimation derived from a strain of −0.62% for the Nb{sub 3}Sn strands. As a result, critical-current degradation caused by the coil manufacturing process was not observed. The results of the performance verification tests indicate that the model coil met the design requirements. Consequently, the manufacturing process of the JT-60SA CS was established.

  4. Exercise testing and hemodynamic performance in healthy elderly persons

    International Nuclear Information System (INIS)

    Hitzhusen, J.C.; Hickler, R.B.; Alpert, J.S.; Doherty, P.W.

    1984-01-01

    To determine the effect of age on cardiovascular performance, 39 healthy elderly men and women, 70 to 83 years old, underwent treadmill thallium-201 exercise perfusion imaging and radionuclide equilibrium angiography at rest and during supine bicycle exercise. Five volunteers who had a positive exercise thallium test response were excluded from the study. Radionuclide left ventricular ejection fraction, regional wall abnormalities, relative cardiac output, stroke volume, end-diastolic volume and end-systolic volume were measured. Seventy-four percent of the subjects maintained or increased their ejection fraction with exercise. With peak exercise, mean end-diastolic volume did not change, end-systolic volume decreased and cardiac output and stroke volume increased. Moreover, in 35% of the subjects, minor regional wall motion abnormalities developed during exercise. There was no significant difference in the response of men and women with regard to these variables. However, more women than men had difficulty performing bicycle ergometry because they had never bicycled before. Subjects who walked daily performed the exercise tests with less anxiety and with a smaller increase in heart rate and systolic blood pressure

  5. Performance norms for a rhesus monkey neuropsychological testing battery: acquisition and long-term performance.

    Science.gov (United States)

    Weed, M R; Taffe, M A; Polis, I; Roberts, A C; Robbins, T W; Koob, G F; Bloom, F E; Gold, L H

    1999-10-25

    A computerized behavioral battery based upon human neuropsychological tests (CANTAB, CeNeS, Cambridge, UK) has been developed to assess cognitive behaviors of rhesus monkeys. Monkeys reliably performed multiple tasks, providing long-term assessment of changes in a number of behaviors for a given animal. The overall goal of the test battery is to characterize changes in cognitive behaviors following central nervous system (CNS) manipulations. The battery addresses memory (delayed non-matching to sample, DNMS; spatial working memory, using a self-ordered spatial search task, SOSS), attention (intra-/extra-dimensional shift, ID/ED), motivation (progressive-ratio, PR), reaction time (RT) and motor coordination (bimanual task). As with human neuropsychological batteries, different tasks are thought to involve different neural substrates, and therefore performance profiles should assess function in particular brain regions. Monkeys were tested in transport cages, and responding on a touch sensitive computer monitor was maintained by food reinforcement. Parametric manipulations of several tasks demonstrated the sensitivity of performance to increases in task difficulty. Furthermore, the factors influencing difficulty for rhesus monkeys were the same as those shown to affect human performance. Data from this study represent performance of a population of healthy normal monkeys that will be used for comparison in subsequent studies of performance following CNS manipulations such as infection with simian immunodeficiency virus (NeuroAIDS) or drug administration.

  6. Performance of a rapid self-test for detection of Trichomonas vaginalis in South Africa and Brazil

    NARCIS (Netherlands)

    Jones, Heidi E.; Lippman, Sheri A.; Caiaffa-Filho, Helio H.; Young, Taryn; van de Wijgert, Janneke H. H. M.

    2013-01-01

    Women participating in studies in Brazil (n = 695) and South Africa (n = 230) performed rapid point-of-care tests for Trichomonas vaginalis on self-collected vaginal swabs. Using PCR as the gold standard, rapid self-testing achieved high specificity (99.1%; 95% confidence interval [CI], 98.2 to

  7. Performance testing of waste forms in a tuff environment

    International Nuclear Information System (INIS)

    Oversby, V.M.

    1983-11-01

    This paper describes experimental work conducted to establish the chemical composition of water which will have reacted with Topopah Spring Member tuff prior to contact with waste packages. The experimental program to determine the behavior of spent fuel and borosilicate glass in the presence of this water is then described. Preliminary results of experiments using spent fuel segments with defects in the Zircaloy cladding are presented. Some results from parametric testing of a borosilicate glass with tuff and 304L stainless steel are also discussed. Experiments conducted using Topopah Spring tuff and J-13 well water have been conducted to provide an estimate of the post-emplacement environment for waste packages in a repository at Yucca Mountain. The results show that emplacement of waste packages should cause only small changes in the water chemistry and rock mineralogy. The changes in environment should not have any detrimental effects on the performance of metal barriers or waste forms. The NNWSI waste form testing program has provided preliminary results related to the release rate of radionuclides from the waste package. Those results indicate that release rates from both spent fuel and borosilicate glass should be below 1 part in 10 5 per year. Future testing will be directed toward making release rate testing more closely relevant to site specific conditions. 17 references, 7 figures

  8. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    International Nuclear Information System (INIS)

    Cuevas V, G.; Avila N, A.; Calleros M, G.

    2013-10-01

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  9. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas V, G. [Global Nuclear Fuel, Americas, 3901 Castle Hayne Road, Wilmington, North Carolina (United States); Avila N, A.; Calleros M, G., E-mail: Gabriel.Cuevas-Vivas@gnf.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verda, Carretera Veracruz-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2013-10-15

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  10. Test results of the SMES model coil. Pulse performance

    International Nuclear Information System (INIS)

    Hamajima, Takataro; Shimada, Mamoru; Ono, Michitaka

    1998-01-01

    A model coil for superconducting magnetic energy storage (SMES model coil) has been developed to establish the component technologies needed for a small-scale 100 kWh SMES device. The SMES model coil was fabricated, and then performance tests were carried out in 1996. The coil was successfully charged up to around 30 kA and down to zero at the same ramp rate of magnetic field experienced in a 100 kWh SMES device. AC loss in the coil was measured by an enthalpy method as parameters of ramp rate and flat top current. The results were evaluated by an analysis and compared with short-sample test results. The measured hysteresis loss is in good agreement with that estimated from the short-sample results. It was found that the coupling loss of the coil consists of two major coupling time constants. One is a short time constant of about 200 ms, which is in agreement with the test results of a short real conductor. The other is a long time constant of about 30 s, which could not be expected from the short sample test results. (author)

  11. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Gannon, J.; Kraushaar, P.; Mcinturff, A.; Nehring, R.; Saladin, V.; Savord, T.; Sorrensen, G.; Smellie, R.; Tool, G.; Voy, D.

    1993-05-01

    The intent of the Accelerator System String Test (ASST) is to obtain data for model verification and information on the magnitudes of pressures and voltages encountered in an accelerator environment. The ASST milestone run was achieved during July and August, 1992 and consisted of demonstrating the accelerator components could be configured together as a system operating at full current. Following the milestone run, the string was warmed to counteract some design flaws that impeded the operational range. The string was again cooled to cryogenic temperatures in October, and a comprehensive power testing program was conducted through the end of January, 1993. This paper describes how the collider arc components operate in an accelerator environment during quenches induced by firing both strip heaters and spot heaters. Evaluation of the data illustrates how variations in the design parameters on magnets used in a string environment can impact system performance

  12. Performance Tests of CMSSW on the CernVM

    CERN Document Server

    Petek, Marko

    2012-01-01

    goal of allowing the execution of the experiment's software on different operating systems in an easy way for the users. To achieve this it makes use of Virtual Machine images consisting of a JEOS (Just Enough Operational System) Linux image, bundled with CVMFS, a distributed file system for software. This image can this be run with a proper virtualizer on most of the platforms available. It also aggressively caches data on the local user's machine so that it can operate disconnected from the network. CMS wanted to compare the performance of the CMS Software running in the virtualized environment with the same software running on a native Linux box. To answer this need a series of tests were made on a controlled environment during 2010-2011. This work presents the results of those tests.

  13. Design and Performance Test of Locking Curved-Nut

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Min Cheol; Kang, Ho Sung; Kim, Do Yeop; Lee, Suk Yong; Lee, Eung Suk [Chungbuk Nat’l Univ., Cheongju (Korea, Republic of); Jeong, Hui Jong [Viblock Company, Cheongwon (Korea, Republic of)

    2017-03-15

    Many types of locking nut are commercializing in the various industries where has heavy vibration. Because Nut's loosing causes a serious accident. But the most locking nuts are too expensive as the complicate manufacturing process. In this study, we design the new type of locking nut, 'Curved-Nut' that is relatively simple making process. We study a relation between the elastic energy and the nut loosing mechanism. So it is analysed, the elastic energy of Curved-Nut comparing with the locking test. The Curved-Nut was manufactured on the commercial nut using a milling tool with horizontal cutting, one or two time under the nut. As the result, the more elastic energy the more prevent the loosing of the nut. We verified the performance of the loosing nut using the vibration testing equipment (NAS3350).

  14. A Modified T-Test for Football Referees to Test Agility, Quickness and Sprint Performances

    Science.gov (United States)

    Muniroglu, S.; Subak, E.

    2018-01-01

    The football referees perform many actions as jogging, running, sprinting, side steps and backward steps during a football match. Further, the football referees change match activities every 5-6 seconds. Many tests are being conducted to determine the physical levels and competences of football referees like 50 m running, 200 m running, 12 minutes…

  15. AULA virtual reality test as an attention measure: convergent validity with Conners' Continuous Performance Test.

    Science.gov (United States)

    Díaz-Orueta, Unai; Garcia-López, Cristina; Crespo-Eguílaz, Nerea; Sánchez-Carpintero, Rocío; Climent, Gema; Narbona, Juan

    2014-01-01

    The majority of neuropsychological tests used to evaluate attention processes in children lack ecological validity. The AULA Nesplora (AULA) is a continuous performance test, developed in a virtual setting, very similar to a school classroom. The aim of the present study is to analyze the convergent validity between the AULA and the Continuous Performance Test (CPT) of Conners. The AULA and CPT were administered correlatively to 57 children, aged 6-16 years (26.3% female) with average cognitive ability (IQ mean = 100.56, SD = 10.38) who had a diagnosis of attention deficit/hyperactivity disorder (ADHD) according to DSM-IV-TR criteria. Spearman correlations analyses were conducted among the different variables. Significant correlations were observed between both tests in all the analyzed variables (omissions, commissions, reaction time, and variability of reaction time), including for those measures of the AULA based on different sensorial modalities, presentation of distractors, and task paradigms. Hence, convergent validity between both tests was confirmed. Moreover, the AULA showed differences by gender and correlation to Perceptual Reasoning and Working Memory indexes of the WISC-IV, supporting the relevance of IQ measures in the understanding of cognitive performance in ADHD. In addition, the AULA (but not Conners' CPT) was able to differentiate between ADHD children with and without pharmacological treatment for a wide range of measures related to inattention, impulsivity, processing speed, motor activity, and quality of attention focus. Additional measures and advantages of the AULA versus Conners' CPT are discussed.

  16. Performance testing of a small vertical-axis wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, R.; Tullis, S.; Ziada, S. [McMaster Univ., Hamilton, ON (Canada). Dept. of Mechanical Engineering

    2007-07-01

    Full-scale wind tunnel testing of a prototype 3.5 kW vertical-axis wind turbine (VAWT) was conducted in a low speed wind tunnel in Ottawa. The tests were conducted to determine nominal power curves as well as the system's structural integrity, safety and operational characteristics. Dimensionless power curves were used to assess the relation between the wind turbine's rotary speed and the produced power for various wind speeds. Tests began at the lowest wind speed and revolutions per minute (RPM) and were gradually increased. A proximity sensor was used to determine the passing frequency of spaced bolts. The aerodynamic performance of the turbine was evaluated using a servo-controlled mechanical variable load with a disc brake calliper and electro-hydraulic servo-actuator. A load cell was used to measure torque produced by the turbine. An active closed loop speed control system was used to regulate the rotary speed of the turbine. The system used a high gain proportional control law to guarantee stability. Calculated power was based on the average rotary speed measurement. Results of the study suggested that the dimensional power performance of the turbine could be predicted from the curve for all rotary speeds and for wind speeds between 8 and 16 m/s. The maximum power coefficient of 0.3 occurred at a tip speed ratio of 1.6. Test results demonstrated that the turbine reached its rated power at 14 m/s. However, the range of tip speed ratios for power production were lower than the range for most other small VAWT. 2 refs., 3 figs.

  17. The VUV instrument SPICE for Solar Orbiter: performance ground testing

    Science.gov (United States)

    Caldwell, Martin E.; Morris, Nigel; Griffin, Douglas K.; Eccleston, Paul; Anderson, Mark; Pastor Santos, Carmen; Bruzzi, Davide; Tustain, Samuel; Howe, Chris; Davenne, Jenny; Grundy, Timothy; Speight, Roisin; Sidher, Sunil D.; Giunta, Alessandra; Fludra, Andrzej; Philippon, Anne; Auchere, Frederic; Hassler, Don; Davila, Joseph M.; Thompson, William T.; Schuehle, Udo H.; Meining, Stefan; Walls, Buddy; Phelan, P.; Dunn, Greg; Klein, Roman M.; Reichel, Thomas; Gyo, Manfred; Munro, Grant J.; Holmes, William; Doyle, Peter

    2017-08-01

    SPICE is an imaging spectrometer operating at vacuum ultraviolet (VUV) wavelengths, 70.4 - 79.0 nm and 97.3 - 104.9 nm. It is a facility instrument on the Solar Orbiter mission, which carries 10 science instruments in all, to make observations of the Sun's atmosphere and heliosphere, at close proximity to the Sun, i.e to 0.28 A.U. at perihelion. SPICE's role is to make VUV measurements of plasma in the solar atmosphere. SPICE is designed to achieve spectral imaging at spectral resolution >1500, spatial resolution of several arcsec, and two-dimensional FOV of 11 x16arcmins. The many strong constraints on the instrument design imposed by the mission requirements prevent the imaging performance from exceeding those of previous instruments, but by being closer to the sun there is a gain in spatial resolution. The price which is paid is the harsher environment, particularly thermal. This leads to some novel features in the design, which needed to be proven by ground test programs. These include a dichroic solar-transmitting primary mirror to dump the solar heat, a high in-flight temperature (60deg.C) and gradients in the optics box, and a bespoke variable-line-spacing grating to minimise the number of reflective components used. The tests culminate in the systemlevel test of VUV imaging performance and pointing stability. We will describe how our dedicated facility with heritage from previous solar instruments, is used to make these tests, and show the results, firstly on the Engineering Model of the optics unit, and more recently on the Flight Model. For the keywords, select up to 8 key terms for a search on your manuscript's subject.

  18. Applying dynamic data collection to improve dry electrode system performance for a P300-based brain-computer interface

    Science.gov (United States)

    Clements, J. M.; Sellers, E. W.; Ryan, D. B.; Caves, K.; Collins, L. M.; Throckmorton, C. S.

    2016-12-01

    Objective. Dry electrodes have an advantage over gel-based ‘wet’ electrodes by providing quicker set-up time for electroencephalography recording; however, the potentially poorer contact can result in noisier recordings. We examine the impact that this may have on brain-computer interface communication and potential approaches for mitigation. Approach. We present a performance comparison of wet and dry electrodes for use with the P300 speller system in both healthy participants and participants with communication disabilities (ALS and PLS), and investigate the potential for a data-driven dynamic data collection algorithm to compensate for the lower signal-to-noise ratio (SNR) in dry systems. Main results. Performance results from sixteen healthy participants obtained in the standard static data collection environment demonstrate a substantial loss in accuracy with the dry system. Using a dynamic stopping algorithm, performance may have been improved by collecting more data in the dry system for ten healthy participants and eight participants with communication disabilities; however, the algorithm did not fully compensate for the lower SNR of the dry system. An analysis of the wet and dry system recordings revealed that delta and theta frequency band power (0.1-4 Hz and 4-8 Hz, respectively) are consistently higher in dry system recordings across participants, indicating that transient and drift artifacts may be an issue for dry systems. Significance. Using dry electrodes is desirable for reduced set-up time; however, this study demonstrates that online performance is significantly poorer than for wet electrodes for users with and without disabilities. We test a new application of dynamic stopping algorithms to compensate for poorer SNR. Dynamic stopping improved dry system performance; however, further signal processing efforts are likely necessary for full mitigation.

  19. Alternate performance standard project: Interpreting the post-construction test

    International Nuclear Information System (INIS)

    Williamson, A.D.; McDonough, S.E.

    1993-01-01

    The paper describes the results of a project commissioned by the State of Florida, in cooperation with the US Environmental Protection Agency, as one portion of the Florida Radon Research Program (FRRP). The purpose of the FRRP is to provide technical support for a statewide Building Standard for Radon-Resistant Construction currently in the rulemaking process. In this case the information provides technical background for a post-construction radon test specified as a performance element of the code which accompanies the prescriptive alternative that does not incorporate active radon reduction systems

  20. Performance evaluation of the Solar Building Test Facility

    Science.gov (United States)

    Jensen, R. N.

    1981-01-01

    The general performance of the NASA Solar Building Test Facility (SBTF) and its subsystems and components over a four year operational period is discussed, and data are provided for a typical one year period. The facility consists of a 4645 sq office building modified to accept solar heated water for operation of an absorption air conditioner and a baseboard heating system. An adjoining 1176 sq solar flat plate collector field with a 114 cu tank provides the solar heated water. The solar system provided 57 percent of the energy required for heating and cooling on an annual basis. The average efficiency of the solar collectors was 26 percent over a one year period.

  1. We're All in This Together Now: Group Performance Feedback to Increase Classroom Team Data Collection

    Science.gov (United States)

    Pellecchia, Melanie; Connell, James E.; Eisenhart, Donald; Kane, Meghan; Schoener, Christine; Turkel, Kimberly; Riley, Megan; Mandell, David S.

    2011-01-01

    This study's primary goal was to evaluate the use of performance feedback procedures delivered to a classroom team to increase daily data collection. Performance feedback (PFB) was delivered to four classroom teams responsible for the daily collection of data representing student performance during prescribed instructional activities. Using a…

  2. Performance testing of thermal analysis codes for nuclear fuel casks

    International Nuclear Information System (INIS)

    Sanchez, L.C.

    1987-01-01

    In 1982 Sandia National Laboratories held the First Industry/Government Joint Thermal and Structural Codes Information Exchange and presented the initial stages of an investigation of thermal analysis computer codes for use in the design of nuclear fuel shipping casks. The objective of the investigation was to (1) document publicly available computer codes, (2) assess code capabilities as determined from their user's manuals, and (3) assess code performance on cask-like model problems. Computer codes are required to handle the thermal phenomena of conduction, convection and radiation. Several of the available thermal computer codes were tested on a set of model problems to assess performance on cask-like problems. Solutions obtained with the computer codes for steady-state thermal analysis were in good agreement and the solutions for transient thermal analysis differed slightly among the computer codes due to modeling differences

  3. WIPP [Waste Isolation Pilot Plant] test phase plan: Performance assessment

    International Nuclear Information System (INIS)

    1990-04-01

    The U.S. Department of Energy (DOE) is responsible for managing the disposition of transuranic (TRU) wastes resulting from nuclear weapons production activities of the United States. These wastes are currently stored nationwide at several of the DOE's waste generating/storage sites. The goal is to eliminate interim waste storage and achieve environmentally and institutionally acceptable permanent disposal of these TRU wastes. The Waste Isolation Pilot Plant (WIPP) in southeastern New Mexico is being considered as a disposal facility for these TRU wastes. This document describes the first of the following two major programs planned for the Test Phase of WIPP: Performance Assessment -- determination of the long-term performance of the WIPP disposal system in accordance with the requirements of the EPA Standard; and Operations Demonstration -- evaluation of the safety and effectiveness of the DOE TRU waste management system's ability to emplace design throughput quantities of TRU waste in the WIPP underground facility. 120 refs., 19 figs., 8 tabs

  4. Testing of camera performance standards at steady and local overloading

    International Nuclear Information System (INIS)

    Keszthelyine Landori, S.; Adorjanne Farkas, M.; Csirik, J.

    1983-01-01

    Camera performance standards are usually given for low count rates and uniform irradiation. A conventional analog gamma camera system (Gamma MB 9100 manufactured under the know-how of Picker DC 4/12 in Hungary) was studied on the basis of the Picker test procedure and the NEMA standard system. Uniformity, linearity, spatial and energy resolution were measured at high count rates and uniform irradiation (steady overloading). Linearity was studied at local overloading. Linearity, spatial and energy resolution were measured by a 1024-channel analyzer-computer system of KFKI, Hungary. The data were evaluated on the basis of NEMA standards, while uniformity was measured by the Gamma data processing system and evaluated by special SEGAMS programs. Performance variations were studied between 7500 cps and 75.000 cps pulse rates. Spatial and energy resolution were influenced strongly, uniformity slightly by pulse rates, while linearity did not change at all. Linearity was not influenced even by local overloading. (author)

  5. Cryogenic and Gas System Piping Pressure Tests (A Collection of PT Permits)

    International Nuclear Information System (INIS)

    Rucinski, Russell A.

    2002-01-01

    This engineering note is a collection of pipe pressure testing documents for various sections of piping for the D-Zero cryogenic and gas systems. High pressure piping must conform with FESHM chapter 5031.1. Piping lines with ratings greater than 150 psig have a pressure test done before the line is put into service. These tests require the use of pressure testing permits. It is my intent that all pressure piping over which my group has responsibility conforms to the chapter. This includes the liquid argon and liquid helium and liquid nitrogen cryogenic systems. It also includes the high pressure air system, and the high pressure gas piping of the WAMUS and MDT gas systems. This is not an all inclusive compilation of test documentation. Some piping tests have their own engineering note. Other piping section test permits are included in separate safety review documents. So if it isn't here, that doesn't mean that it wasn't tested. D-Zero has a back up air supply system to add reliability to air compressor systems. The system includes high pressure piping which requires a review per FESHM 5031.1. The core system consists of a pressurized tube trailer, supply piping into the building and a pressure reducing regulator tied into the air compressor system discharge piping. Air flows from the trailer if the air compressor discharge pressure drops below the regulator setting. The tube trailer is periodically pumped back up to approximately 2000 psig. A high pressure compressor housed in one of the exterior buildings is used for that purpose. The system was previously documented, tested and reviewed for Run I, except for the recent addition of piping to and from the high pressure compressor. The following documents are provided for review of the system: (1) Instrument air flow schematic, drg. 3740.000-ME-273995 rev. H; (2) Component list for air system; (3) Pressure testing permit for high pressure piping; (4) Documentation from Run I contained in D-Zero Engineering note

  6. Individual differences in infant fearfulness and cognitive performance: a testing, performance, or competence effect?

    Science.gov (United States)

    Rieser-Danner, Loretta A

    2003-02-01

    The author conducted 2 studies to examine the relations between infant fear and cognitive testing performance in 12-month-old infants. In Study 1, fear was assessed by using 2 standard temperament questionnaires and a laboratory-based, standardized stranger approach. Individual differences in cognitive development were assessed using the Object Permanence Scale of the Infant Psychological Development Scales (I. C. Uzgiris & J. M. Hunt, 1975). All 3 assessments of fear significantly predicted object permanence performance, with correlations ranging from -.32 to -.35. In Study 2, fear was assessed via a maternal report questionnaire, and habituation performance was assessed via a basic-level categorization task. Familiarity with the examiner and with the testing environment was manipulated to test for a familiarity influence on performance. Testing revealed individual differences in both fear and habituation. Results suggest that highly fearful infants required more trials to habituate and were less likely to meet the habituation criterion than infants who were less fearful. Methodological and conceptual implications of these results are discussed.

  7. The development and performance testing of a biodegradable scale inhibitor

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, Julie; Fidoe, Steve; Jones, Chris

    2006-03-15

    The oil industry is currently facing severe restrictions concerning the discharge of oil field chemicals into the environment. Many commonly used materials in both topside and downhole applications are phased for substitution for use in the North Sea, and more will be identified. The development of biodegradable and low toxicity chemicals, which afford equal or improved efficacy, compared to conventional technology, available at a competitive price, is a current industry challenge. A range of biodegradable materials are increasingly available, however their limited performance can result in a restricted range of applications. This paper discusses the development and commercialization of a readily biodegradable scale inhibitor, ideal for use in topside applications. This material offers a broad spectrum of activity, notably efficiency against barium sulphate, calcium sulphate and calcium carbonate scales, in a range of water chemistries. A range of performance testing, compatibility, stability and OCNS dataset will be presented. Comparisons with commonly used chemicals have been made to identify the superior performance of this phosphate ester. This paper will discuss a scale inhibitor suitable for use in a variety of conditions which offers enhanced performance combined with a favourable biodegradation profile. This material is of great benefit to the industry, particularly in North Sea applications. (author) (tk)

  8. Performance test results of mock-up test facility of HTTR hydrogen production system

    International Nuclear Information System (INIS)

    Ohashi, Hirofumi; Inaba, Yoshitomo; Nishihara, Tetsuo

    2004-01-01

    For the purpose to demonstrate effectiveness of high-temperature nuclear heat utilization, Japan Atomic Energy Research Institute has been developing a hydrogen production system and has planned to connect the hydrogen production system to High Temperature Engineering Test Reactor (HTTR). Prior to construction of a HTTR hydrogen production system, a mock-up test facility was constructed to investigate transient behavior of the hydrogen production system and to establish system controllability. The Mock-up test facility with a full-scale reaction tube is an approximately 1/30-scale model of the HTTR hydrogen production system and an electric heater is used as a heat source instead of a reactor. After its construction, a performance test of the test facility was carried out in the same pressure and temperature conditions as those of the HTTR hydrogen production system to investigate its performance such as hydrogen production ability, controllability and so on. It was confirmed that hydrogen was stably produced with a hot helium gas about 120m 3 /h, which satisfy the design value, and thermal disturbance of helium gas during the start-up could be mitigated within the design value by using a steam generator. The mock-up test of the HTTR hydrogen production system using this facility will continue until 2004. (author)

  9. Tests Performed on Hydraulic Turbines at Commissioning or after Capital Repairs. Part II. Tests Performed on a 6.5 MW Kaplan Turbine

    Directory of Open Access Journals (Sweden)

    Adrian Cuzmoş

    2015-07-01

    Full Text Available The paper presents the tests performed on a hydraulic turbine on commissioning, the devices, test methods and the results obtained from the respective tests, as well as the conclusions and recommendations resulted from these tests. This kind of tests can be performed for the verification of guarantees.

  10. Experimental Evaluation of Pool Fire Suppression Performance of Sodium Leak Collection Tray in Open Air

    International Nuclear Information System (INIS)

    Parida, F.C.; Rao, P.M.; Ramesh, S.S.; Malarvizhi, B.; Gopalakrishnan, V.; Rao, E.H.V.M.; Kasinathan, N.; Kannan, S.E.

    2006-01-01

    In the event of sodium leakage from heat transfer circuits of fast breeder reactors (FBR), liquid sodium catches fire in ambient air leading to production of flame, smoke and heat. One of the passive fire protection methods involves immediate collection of the leaking sodium to a sodium hold-up vessel (SHV) covered with a sloping cover tray (SCT) having a few drain pipes and one vent pipe (as in Fig. 1). As soon as the liquid sodium falls on the sloping cover tray, gravity guides the sodium through drain pipes into the bottom tray in which self-extinction occurs due to oxygen starvation. This sodium fire protection equipment called leak collection tray (LCT) works without the intervention of an operator and external power source. A large number of LCTs are strategically arranged under the sodium circulating pipe lines in the FBR plants to serve as passive suppression devices. In order to test the efficacy of the LCT, four tests were conducted. Two tests were with LCT having three drain pipes and rest with one. In each experiment, nearly 40 kg of hot liquid sodium at 550 deg. C was discharged on the LCT in the open air. Continuous on-line monitoring of temperature at strategic locations (∼ 28 points) were carried out. Colour video-graphy was employed for taking motion pictures of various time-dependent events like sodium dumping, appearance of flame and release of smoke through vent pipes. After self-extinction of sodium fire, the LCT was allowed to cool overnight in an argon atmosphere. Solid samples of sodium debris in the SCT and SHV were collected by manual core drilling machine. The samples were subjected to chemical analysis for determination of unburnt and burnt sodium. The results of the four tests revealed an interesting feature: LCT with three drain pipes showed far lower sodium collection efficiency and much higher sodium combustion than that with just one drain pipe. Thermal fluctuations in temperature sensor located near the tip of the drain pipe have

  11. Beta Testing StraboSpot: Perspectives on mobile field mapping and data collection

    Science.gov (United States)

    Bunse, E.; Graham, K. A.; Rufledt, C.; Walker, J. D.; Müller, A.; Tikoff, B.

    2017-12-01

    Geologic field mapping has recently transitioned away from traditional techniques (e.g. field notebooks, paper mapping, Brunton compasses) and towards mobile `app' mapping technology. The StraboSpot system (Strabo) is an open-source solution for collection and storage for geologic field, microstructural, and lab-based data. Strabo's mission is to "enable recording and sharing data within the geoscience community, encourage interdisciplinary research, and facilitate the investigation of scientific questions that cannot currently be addressed" (Walker et al., 2015). Several mobile application beta tests of the system, on both Android and Apple iOS platforms using smartphones and tablets, began in Summer 2016. Students at the 2016 and 2017 University of Kansas Field Camps used Strabo in place of ArcGIS for Desktop on Panasonic Toughbooks, to field map two study areas. Strabo was also field tested by students of graduate and undergraduate level for both geo/thermochronologic sample collection and reconnaissance mapping associated with regional tectonic analysis in California. Throughout this period of testing, the app was geared toward structural and tectonic geologic data collection, but is versatile enough for other communities to currently use and is expanding to accommodate the sedimentology and petrology communities. Overall, users in each of the beta tests acclimated quickly to using Strabo for field data collection. Some key advantages to using Strabo over traditional mapping methods are: (1) Strabo allows for consolidation of materials in the field; (2) helps students track their position in the field with integrated GPS; and (3) Strabo data is in a uniform format making it simple for geologists to collaborate. While traditional field methods are not likely to go out of style in the near future, Strabo acts as a bridge between professional and novice geologists by providing a tool that is intuitive on all levels of geological and technological experience and

  12. Risk Assessment of Wastewater Collection Performance Using the Fuzzy Decision-making Approach

    Directory of Open Access Journals (Sweden)

    Maedeh Asgarian

    2015-10-01

    Full Text Available Wastewater collection network simulation in normal conditions dose not provide performance assessment in unusual circumstances. In this paper, a model has been developed for risk assessment of wastewater collection systems to manage their performance under natural or man-made critical conditions. In this model, certain criteria were defined, fuzzy MADM techniques were exploited, and a questionnaire was employed to measure such risk parameters as the probability of threats, the severity of their impacts, and the vulnerability of the network components. Based on the calculated magnitude of the risks, the threats and hazards were classified into groups ranging from low-risk to high-risk threats. The approaches adopted to combat the risks were also classified into the following three categories: "to deal with the risk", "risk shifting", and "risk taking". This process was implemented for the wastewater collection system in Shahrak-Gharb District in Tehran as a case study. ‘Introduction of chemical pollutants into the sewers’ and ‘drastic changes in wastewater quality’ were identified as the most threatening crises for the district and the ‘risk reduction strategy’ was proposed for combating the critical conditions in this district.

  13. Five-Kilometers Time Trial: Preliminary Validation of a Short Test for Cycling Performance Evaluation.

    Science.gov (United States)

    Dantas, Jose Luiz; Pereira, Gleber; Nakamura, Fabio Yuzo

    2015-09-01

    The five-kilometer time trial (TT5km) has been used to assess aerobic endurance performance without further investigation of its validity. This study aimed to perform a preliminary validation of the TT5km to rank well-trained cyclists based on aerobic endurance fitness and assess changes of the aerobic endurance performance. After the incremental test, 20 cyclists (age = 31.3 ± 7.9 years; body mass index = 22.7 ± 1.5 kg/m(2); maximal aerobic power = 360.5 ± 49.5 W) performed the TT5km twice, collecting performance (time to complete, absolute and relative power output, average speed) and physiological responses (heart rate and electromyography activity). The validation criteria were pacing strategy, absolute and relative reliability, validity, and sensitivity. Sensitivity index was obtained from the ratio between the smallest worthwhile change and typical error. The TT5km showed high absolute (coefficient of variation 0.95) reliability of performance variables, whereas it presented low reliability of physiological responses. The TT5km performance variables were highly correlated with the aerobic endurance indices obtained from incremental test (r > 0.70). These variables showed adequate sensitivity index (> 1). TT5km is a valid test to rank the aerobic endurance fitness of well-trained cyclists and to differentiate changes on aerobic endurance performance. Coaches can detect performance changes through either absolute (± 17.7 W) or relative power output (± 0.3 W.kg(-1)), the time to complete the test (± 13.4 s) and the average speed (± 1.0 km.h(-1)). Furthermore, TT5km performance can also be used to rank the athletes according to their aerobic endurance fitness.

  14. Performance specifications for the extra-analytical phases of laboratory testing: Why and how.

    Science.gov (United States)

    Plebani, Mario

    2017-07-01

    An important priority in the current healthcare scenario should be to address errors in laboratory testing, which account for a significant proportion of diagnostic errors. Efforts made in laboratory medicine to enhance the diagnostic process have been directed toward improving technology, greater volumes and more accurate laboratory tests being achieved, but data collected in the last few years highlight the need to re-evaluate the total testing process (TTP) as the unique framework for improving quality and patient safety. Valuable quality indicators (QIs) and extra-analytical performance specifications are required for guidance in improving all TTP steps. Yet in literature no data are available on extra-analytical performance specifications based on outcomes, and nor is it possible to set any specification using calculations involving biological variability. The collection of data representing the state-of-the-art based on quality indicators is, therefore, underway. The adoption of a harmonized set of QIs, a common data collection and standardised reporting method is mandatory as it will not only allow the accreditation of clinical laboratories according to the International Standard, but also assure guidance for promoting improvement processes and guaranteeing quality care to patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Performance of iron spot test with Arabic bread made from fortified white wheat flour.

    Science.gov (United States)

    Nichols, Erin; Aburto, Nancy; Masa'd, Hanan; Wirth, James; Sullivan, Kevin; Serdula, Mary

    2012-09-01

    The iron spot test (IST) is a simple qualitative technique for determining the presence of added iron in fortified flour. IST performance in bread has never been investigated. If found to perform well, the IST has the potential to provide a field-friendly method for testing bread and thus support the monitoring and evaluation of flour fortification programs. To assess the performance of the IST in Arabic bread made from white wheat flour. Bread samples were collected from 1,737 households during a national micronutrient survey in Jordan. A subsample of Arabic bread (n = 44) was systematically selected for testing by both the IST and spectrophotometry (criterion reference). Performance measures (sensitivity, specificity, and positive and negative predictive values) were calculated using five cutoffs to define the presence of added iron, including > or = 15.0 ppm (approximate level of natural iron in Arabic bread) and four additional cutoffs based on test performance. The iron contents of samples testing negative by IST ranged from 10.4 to 18.4 ppm, with one outlier at 41.0 ppm, which was excluded from subsequent analyses. The iron contents of samples testing positive by IST ranged from 16.1 to 38.4 ppm. With the exception of negative predictive values for the two lowest cutoffs (> or = 15.0 and > or = 16.1 ppm), all performance measures exceeded 83.3%. These results show promise for the IST as an inexpensive, field-friendly method for testing bread that could have a useful role in the monitoring and evaluation process for flour fortification programs.

  16. Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia.

    Science.gov (United States)

    Aralica, Merica; Krleza, Jasna Lenicek

    2017-02-15

    Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level.

  17. Performance tests of the reactor containment structures of HTTR

    International Nuclear Information System (INIS)

    Sakaba, Nariaki; Iigaki, Kazuhiko; Kawaji, Satoshi; Iyoku, Tatsuo

    1998-03-01

    The containment structures of the HTTR consist of the reactor containment vessel (CV), service area (SA) and emergency air purification system, which minimize the release of FPs in the postulated accidents with FP release from the reactor facilities. The CV is designed to withstand the temperature and pressure transients and to be leak-tight within the specified leakage limit even in the case of a rupture of the primary concentric hot gas duct. The pressure of inside of the SA should be maintained slightly lower than that of atmosphere by the emergency air purification system. The radioactive materials are released from the stack to environment via the emergency air purification system under the accident condition. Then the emergency air purification system should remove airborne radio-activities and should maintain proper pressure in the SA. We established the method to measure leak rate of the CV with closed reactor coolant pressure boundary although it is normally measured under opened reactor coolant pressure boundary as employed in LWRs. The CV leak rate test was carried out by the newly developed method and the expected performance was obtained. The SA and emergency air purification system were also confirmed by the performance test. We concluded that the reactor containment structures were fabricated to minimize the release of FPs in the postulated accidents with FP release from the reactor facilities. (author)

  18. Performance Test of BF3 Neutron Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yu Sun; Shin, Ho Cheol [KHNP-CRI, Daejeon (Korea, Republic of); Cho, Jin Bok; Oh, Sae Hyun; Ryou, Seok Jean [USERS, Daejeon (Korea, Republic of)

    2015-10-15

    The neutron detecting system of First-of-a-kind plant such an APR1400 at Shin Kori should have been verified in the condition of low operating temperature and pressure of the primary coolant system before receiving the operation license. Auxiliary Ex-core Neutron Flux Monitoring System (AENFMS) is supposed to be installed using BF3 neutron detector in Shin Kori plant. The performance test of AENFMS was conducted to measure neutron sensitivity, moderation ratio and count rate in the same condition with Ex-core Neutron Flux Monitoring System (ENFMS) of APR1400 to verify its detection characteristics in compliance with the functional requirement. Performance test has been conducted for AENFMS of APR1400 to verify BF3 neutron sensitivity, moderation ration of PE, expecting neutron signal count rate from AENFMS, possible extending cable length from detector to pre-amplifier. As a result of measurement, the neutron sensitivity of 34.246±0.168(95%CI)cps/nv, moderation ratio of 11.343±0.039(95%CI) and AENFMS expecting count rate related to ENFMS of 17.8 times are acceptable in compliance with functional requirement, respectively.

  19. Performance testing of 3D point cloud software

    Directory of Open Access Journals (Sweden)

    M. Varela-González

    2013-10-01

    Full Text Available LiDAR systems are being used widely in recent years for many applications in the engineering field: civil engineering, cultural heritage, mining, industry and environmental engineering. One of the most important limitations of this technology is the large computational requirements involved in data processing, especially for large mobile LiDAR datasets. Several software solutions for data managing are available in the market, including open source suites, however, users often unknown methodologies to verify their performance properly. In this work a methodology for LiDAR software performance testing is presented and four different suites are studied: QT Modeler, VR Mesh, AutoCAD 3D Civil and the Point Cloud Library running in software developed at the University of Vigo (SITEGI. The software based on the Point Cloud Library shows better results in the loading time of the point clouds and CPU usage. However, it is not as strong as commercial suites in working set and commit size tests.

  20. 9978 AND 9975 TYPE B PACKAGING INTERNAL DATA COLLECTION FEASIBILITY TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Fogle, R.

    2012-05-07

    The objective of this report is to document the findings from a series of proof-of-concept tests performed by Savannah River National Laboratory (SRNL) R and D Engineering, for the DOE Packaging Certification Program to determine if a viable radio link could be established from within the stainless steel confines of several drum-style DOE certified Type B radioactive materials packagings. Two in-hand, off-the-shelf radio systems were tested. The first system was a Wi-Fi Librestream Onsight{trademark} camera with a Fortress ES820 Access Point and the second was the On-Ramp Wireless Ultra-Link Processing{trademark} (ULP) radio system. These radio systems were tested within the Model 9975 and 9978 Type B packagings at the SRNL. This report documents the test methods and results. A path forward will also be recommended.

  1. Correlations between the simulated military tasks performance and physical fitness tests at high altitude

    Directory of Open Access Journals (Sweden)

    Eduardo Borba Neves

    2017-11-01

    Full Text Available The aim of this study was to investigate the Correlations between the Simulated Military Tasks Performance and Physical Fitness Tests at high altitude. This research is part of a project to modernize the physical fitness test of the Colombian Army. Data collection was performed at the 13th Battalion of Instruction and Training, located 30km south of Bogota D.C., with a temperature range from 1ºC to 23ºC during the study period, and at 3100m above sea level. The sample was composed by 60 volunteers from three different platoons. The volunteers start the data collection protocol after 2 weeks of acclimation at this altitude. The main results were the identification of a high positive correlation between the 3 Assault wall in succession and the Simulated Military Tasks performance (r = 0.764, p<0.001, and a moderate negative correlation between pull-ups and the Simulated Military Tasks performance (r = -0.535, p<0.001. It can be recommended the use of the 20-consecutive overtaking of the 3 Assault wall in succession as a good way to estimate the performance in operational tasks which involve: assault walls, network of wires, military Climbing Nets, Tarzan jump among others, at high altitude.

  2. Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Matzke, Brett D.

    2009-02-16

    This report describes the experimental and sampling design developed to assess sampling approaches and methods for detecting contamination in a building and clearing the building for use after decontamination. An Idaho National Laboratory (INL) building will be contaminated with BG (Bacillus globigii, renamed Bacillus atrophaeus), a simulant for Bacillus anthracis (BA). The contamination, sampling, decontamination, and re-sampling will occur per the experimental and sampling design. This INL-2 Sample Collection Operational Test is being planned by the Validated Sampling Plan Working Group (VSPWG). The primary objectives are: 1) Evaluate judgmental and probabilistic sampling for characterization as well as probabilistic and combined (judgment and probabilistic) sampling approaches for clearance, 2) Conduct these evaluations for gradient contamination (from low or moderate down to absent or undetectable) for different initial concentrations of the contaminant, 3) Explore judgment composite sampling approaches to reduce sample numbers, 4) Collect baseline data to serve as an indication of the actual levels of contamination in the tests. A combined judgmental and random (CJR) approach uses Bayesian methodology to combine judgmental and probabilistic samples to make clearance statements of the form "X% confidence that at least Y% of an area does not contain detectable contamination” (X%/Y% clearance statements). The INL-2 experimental design has five test events, which 1) vary the floor of the INL building on which the contaminant will be released, 2) provide for varying the amount of contaminant released to obtain desired concentration gradients, and 3) investigate overt as well as covert release of contaminants. Desirable contaminant gradients would have moderate to low concentrations of contaminant in rooms near the release point, with concentrations down to zero in other rooms. Such gradients would provide a range of contamination levels to challenge the sampling

  3. A Universal Motor Performance Test System Based on Virtual Instrument

    Directory of Open Access Journals (Sweden)

    Wei Li

    2014-09-01

    Full Text Available With the development of technology universal motors play a more and more important role in daily life and production, they have been used in increasingly wide field and the requirements increase gradually. How to control the speed and monitor the real-time temperature of motors are key issues. The cost of motor testing system based on traditional technology platform is very high in many reasons. In the paper a universal motor performance test system which based on virtual instrument is provided. The system achieves the precise control of the current motor speed and completes the measurement of real-time temperature of motor bearing support in order to realize the testing of general-purpose motor property. Experimental result shows that the system can work stability in controlling the speed and monitoring the real-time temperature. It has advantages that traditional using of SCM cannot match in speed, stability, cost and accuracy aspects. Besides it is easy to expand and reconfigure.

  4. Comparison of test performance profile for blood tests of liver fibrosis in chronic hepatitis C.

    Science.gov (United States)

    Halfon, Philippe; Bacq, Yannick; De Muret, Anne; Penaranda, Guillaume; Bourliere, Marc; Ouzan, Denis; Tran, Albert; Botta, Danielle; Renou, Christophe; Bréchot, Marie-Claude; Degott, Claude; Paradis, Valérie

    2007-03-01

    We evaluated the test performance profile (TPP) of blood tests of liver fibrosis. Three hundred and fifty-six patients with C chronic hepatitis were included in two centers. Metavir staging of liver specimens by two independent pathologists and the following tests were evaluated: Fibrotest (FT), APRI, FibroMeter (FM), and Hepascore (HS). Metavir stages were: F0: 4%, F1: 55%, F2: 26%, F3: 11%, and F4: 4%. The AUROCs were not significantly different, respectively, FT, FM, APRI, HS: >or=F2: 0.79, 0.78, 0.76, >or=0.76; F3: 0.81, 0.85, 0.81, 0.81; and F4: 0.86, 0.94, 0.92, 0.89. The TPP relies on the paired comparison of blood-test misclassification based on liver specimen, e.g. FT vs FM, respectively: F0+1: 18 vs 28% (p=0.0003), >or=F2: 43 vs 31% (p=0.004). There was no center effect. In those populations, the four blood tests had a similar performance for significant fibrosis (F>or=2), lying in the lower range of published results which is attributable to a low >or=F2 prevalence, and for >or=F3 and F4. However, FM and FT had performance profiles significantly different as a function of fibrosis stages or diagnostic target (fibrosis cut-off). This has to be considered during the interpretation process. Moreover, the performance should be reported with different diagnostic targets.

  5. Shear punch tests performed using a new low compliance test fixture

    International Nuclear Information System (INIS)

    Toloczko, M.B.; Kurtz, R.J.; Hasegawa, A.; Abe, K.

    2002-01-01

    Based on a recent finite element analysis (FEA) study performed on the shear punch test technique, it was suggested that compliance in a test frame and fixturing which is quite acceptable for uniaxial tensile tests, is much too large for shear punch tests. The FEA study suggested that this relatively large compliance was masking both the true yield point and the shape of the load versus displacement trace obtained in shear punch tests. The knowledge gained from the FEA study was used to design a new shear punch test fixture which more directly measures punch tip displacement. The design of this fixture, the traces obtained from this fixture, and the correlation between uniaxial yield stress and shear yield stress obtained using this fixture are presented here. In general, traces obtained from the new fixture contain much less compliance resulting in a trace shape which is more similar in appearance to a corresponding uniaxial tensile trace. Due to the more direct measurement of displacement, it was possible to measure yield stress at an offset shear strain in a manner analogous to yield stress measurement in a uniaxial tensile test. The correlation between shear yield and uniaxial yield was altered by this new yield measurement technique, but the new correlation was not as greatly improved as was suggested would occur from the FEA study

  6. Does interaction matter? Testing whether a confidence heuristic can replace interaction in collective decision-making.

    Science.gov (United States)

    Bang, Dan; Fusaroli, Riccardo; Tylén, Kristian; Olsen, Karsten; Latham, Peter E; Lau, Jennifer Y F; Roepstorff, Andreas; Rees, Geraint; Frith, Chris D; Bahrami, Bahador

    2014-05-01

    In a range of contexts, individuals arrive at collective decisions by sharing confidence in their judgements. This tendency to evaluate the reliability of information by the confidence with which it is expressed has been termed the 'confidence heuristic'. We tested two ways of implementing the confidence heuristic in the context of a collective perceptual decision-making task: either directly, by opting for the judgement made with higher confidence, or indirectly, by opting for the faster judgement, exploiting an inverse correlation between confidence and reaction time. We found that the success of these heuristics depends on how similar individuals are in terms of the reliability of their judgements and, more importantly, that for dissimilar individuals such heuristics are dramatically inferior to interaction. Interaction allows individuals to alleviate, but not fully resolve, differences in the reliability of their judgements. We discuss the implications of these findings for models of confidence and collective decision-making. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Performance testing of LiDAR exploitation software

    Science.gov (United States)

    Varela-González, M.; González-Jorge, H.; Riveiro, B.; Arias, P.

    2013-04-01

    Mobile LiDAR systems are being used widely in recent years for many applications in the field of geoscience. One of most important limitations of this technology is the large computational requirements involved in data processing. Several software solutions for data processing are available in the market, but users are often unknown about the methodologies to verify their performance accurately. In this work a methodology for LiDAR software performance testing is presented and six different suites are studied: QT Modeler, AutoCAD Civil 3D, Mars 7, Fledermaus, Carlson and TopoDOT (all of them in x64). Results depict as QTModeler, TopoDOT and AutoCAD Civil 3D allow the loading of large datasets, while Fledermaus, Mars7 and Carlson do not achieve these powerful performance. AutoCAD Civil 3D needs large loading time in comparison with the most powerful softwares such as QTModeler and TopoDOT. Carlson suite depicts the poorest results among all the softwares under study, where point clouds larger than 5 million points cannot be loaded and loading time is very large in comparison with the other suites even for the smaller datasets. AutoCAD Civil 3D, Carlson and TopoDOT show more threads than other softwares like QTModeler, Mars7 and Fledermaus.

  8. Coordination and collective performance: Cooperative goals boost interpersonal synchrony and task outcomes

    Directory of Open Access Journals (Sweden)

    Jamie S. Allsop

    2016-09-01

    Full Text Available Whether it be a rugby team or a rescue crew, ensuring peak group performance is a primary goal during collective activities. In reality however, groups often suffer from productivity losses that can lead to less than optimal outputs. Where researchers have focused on this problem, inefficiencies in the way team members coordinate their efforts has been identified as one potent source of productivity decrements. Here we set out to explore whether performance on a simple object movement task is shaped by the spontaneous emergence of interpersonally coordinated behavior. Forty-six pairs of participants were instructed to either compete or cooperate in order to empty a container of approximately 100 small plastic balls as quickly and accurately as possible. Each trial was recorded to video and a frame-differencing approach was employed to estimate between-person coordination. The results revealed that cooperative pairs coordinated to a greater extent than their competitive counterparts. Furthermore, coordination, as well as movement regularity were positively related to accuracy, an effect that was most prominent when the task was structured such that opportunities to coordinate were restricted. These findings are discussed with regard to contemporary theories of coordination and collective performance.

  9. Performance evaluation model of a pilot food waste collection system in Suzhou City, China.

    Science.gov (United States)

    Wen, Zongguo; Wang, Yuanjia; De Clercq, Djavan

    2015-05-01

    This paper analyses the food waste collection and transportation (C&T) system in a pilot project in Suzhou by using a novel performance evaluation method. The method employed to conduct this analysis involves a unified performance evaluation index containing qualitative and quantitative indicators applied to data from Suzhou City. Two major inefficiencies were identified: a) low system efficiency due to insufficient processing capacity of commercial food waste facilities; and b) low waste resource utilization due to low efficiency of manual sorting. The performance evaluation indicated that the pilot project collection system's strong points included strong economics, low environmental impact and low social impact. This study also shows that Suzhou's integrated system has developed a comprehensive body of laws and clarified regulatory responsibilities for each of the various government departments to solve the problems of commercial food waste management. Based on Suzhou's experience, perspectives and lessons can be drawn for other cities and areas where food waste management systems are in the planning stage, or are encountering operational problems. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. AIChe equipment testing procedure centrifugal compressors : a guide to performance evaluation and site testing

    CERN Document Server

    AIChE

    2013-01-01

    With its engineer-tested procedures and thorough explanations, Centrifugal Compressors is an essential text for anyone engaged in implementing new technology in equipment design, identifying process problems, and optimizing equipment performance.  This condensed book presents a step by step approach to preparing for, planning, executing, and analyzing tests of centrifugal compressors, with an emphasis on methods that can be conducted on-site and with an acknowledgement of the strengths and limitations of these methods. The book opens with an extensive and detailed section offering definitions

  11. The Urine Marker Test: An Alternative Approach to Supervised Urine Collection for Doping Control.

    Science.gov (United States)

    Elbe, Anne-Marie; Jensen, Stine Nylansted; Elsborg, Peter; Wetzke, Monika; Woldemariam, Getachew A; Huppertz, Bernd; Keller, Ruprecht; Butch, Anthony W

    2016-01-01

    Urine sample collection for doping control tests is a key component of the World Anti-Doping Agency's fight against doping in sport. However, a substantial number of athletes experience difficulty when having to urinate under supervision. Furthermore, it cannot always be ensured that athletes are actually delivering their own urine. A method that can be used to alleviate the negative impact of a supervised urination procedure and which can also identify urine as coming from a specific athlete is the urine marker test. Monodisperse low molecular weight polyethylene glycols (PEGs) are given orally prior to urination. Urine samples can be traced to the donor by analysis of the PEGs previously given. The objective of this study was to investigate the use of the urine marker during urine doping control testing. Two studies investigated athletes' acceptance of this new method via two questionnaires (n = 253). Furthermore, a third study (n = 91) investigated whether ingestion of the marker can identify the urine as coming from a specific person and whether the marker interferes with the detection of prohibited substances. The results indicate that this new method finds wide acceptance both from athletes who have only heard about the procedure and those who have actually tested the new method. Furthermore, the marker, which can identify urine as coming from a specific person, does not interfere with the detection of prohibited substances.

  12. Coastal California's Fog Aerobiology and Ecology: Designing and Testing an Optimal Passive Impactor Collection Unit

    Science.gov (United States)

    Gentry, D.; Whinnery, J. T.; Ly, V. T.; Travers, S. V.; Sagaga, J.; Dahlgren, R. P.

    2017-12-01

    Microorganisms play a major role in our biosphere due to their ability to alter water, carbon and other geochemical cycles. Fog and low-level cloud water can play a major role in dispersing and supporting such microbial diversity. An ideal region to gather these microorganisms for characterization is the central coast of California, where dense fog is common. Fog captured from an unmanned aerial vehicle (UAV) at different altitudes will be analyzed to better understand the nature of microorganisms in the lower atmosphere and their potential geochemical impacts. The capture design consists of a square-meter hydrophobic mesh that hangs from a carbon fiber rod attached to a UAV. The DJI M600, a hexacopter, will be utilized as the transport for the payload, the passive impactor collection unit (PICU). The M600 will hover in a fog bank at altitudes between 10 and 100 m collecting water samples via the PICU. A computational flow dynamics (CFD) model will optimize the PICU's size, shape and placement for maximum capture efficiency and to avoid contamination from the UAV downwash. On board, there will also be an altitude, temperature and barometric pressure sensor whose output is logged to an SD card. A scale model of the PICU has been tested with several different types of hydrophobic meshes in a fog chamber at 90-95% humidity; polypropylene was found to capture the fog droplets most efficiently at a rate of .0042 g/cm2/hour. If the amount collected is proportional to the area of mesh, the estimated amount of water collected under optimal fog and flight conditions by the impactor is 21.3 g. If successful, this work will help identify the organisms living in the lower atmosphere as well as their potential geochemical impacts.

  13. Performance of rapid tests and algorithms for HIV screening in Abidjan, Ivory Coast.

    Science.gov (United States)

    Loukou, Y G; Cabran, M A; Yessé, Zinzendorf Nanga; Adouko, B M O; Lathro, S J; Agbessi-Kouassi, K B T

    2014-01-01

    Seven rapid diagnosis tests (RDTs) of HIV were evaluated by a panel group who collected serum samples from patients in Abidjan (HIV-1 = 203, HIV-2 = 25, HIV-dual = 25, HIV = 305). Kit performances were recorded after the reference techniques (enzyme-linked immunosorbent assay). The following RDTs showed a sensitivity of 100% and a specificity higher than 99%: Determine, Oraquick, SD Bioline, BCP, and Stat-Pak. These kits were used to establish infection screening strategies. The combination with 2 or 3 of these tests in series or parallel algorithms showed that series combinations with 2 tests (Oraquick and Bioline) and 3 tests (Determine, BCP, and Stat-Pak) gave the best performances (sensitivity, specificity, positive predictive value, and negative predictive value of 100%). However, the combination with 2 tests appeared to be more onerous than the combination with 3 tests. The combination with Determine, BCP, and Stat-Pak tests serving as a tiebreaker could be an alternative to the HIV/AIDS serological screening in Abidjan.

  14. Theoretical and testing performance of an innovative indirect evaporative chiller

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yi; Xie, Xiaoyun [Department of Building Science and Technology, Tsinghua University, Beijing (China)

    2010-12-15

    An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirect evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller

  15. Acute Oxidative Effect and Muscle Damage after a Maximum 4 Min Test in High Performance Athletes.

    Directory of Open Access Journals (Sweden)

    Heros Ribeiro Ferreira

    Full Text Available The purpose of this investigation was to determine lipid peroxidation markers, physiological stress and muscle damage in elite kayakers in response to a maximum 4-min kayak ergometer test (KE test, and possible correlations with individual 1000m kayaking performances. The sample consisted of twenty-three adult male and nine adult female elite kayakers, with more than three years' experience in international events, who voluntarily took part in this study. The subjects performed a 10-min warm-up, followed by a 2-min passive interval, before starting the test itself, which consisted of a maximum 4-min work paddling on an ergometer; right after the end of the test, an 8 ml blood sample was collected for analysis. 72 hours after the test, all athletes took part in an official race, when then it was possible to check their performance in the on site K1 1000m test (P1000m. The results showed that all lipoproteins and hematological parameters tested presented a significant difference (p≤0.05 after exercise for both genders. In addition, parameters related to muscle damage such as lactate dehydrogenase (LDH and creatine kinase (CK presented significant differences after stress. Uric acid presented an inverse correlation with the performance (r = -0.76, while CK presented a positive correlation (r = 0.46 with it. Based on these results, it was possible to verify muscle damage and the level of oxidative stress caused by indoor training with specific ergometers for speed kayaking, highlighting the importance of analyzing and getting to know the physiological responses to this type of training, in order to provide information to coaches and optimize athletic performance.

  16. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    Science.gov (United States)

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test

  17. Swarm intelligence in animal groups: when can a collective out-perform an expert?

    Directory of Open Access Journals (Sweden)

    Konstantinos V Katsikopoulos

    Full Text Available An important potential advantage of group-living that has been mostly neglected by life scientists is that individuals in animal groups may cope more effectively with unfamiliar situations. Social interaction can provide a solution to a cognitive problem that is not available to single individuals via two potential mechanisms: (i individuals can aggregate information, thus augmenting their 'collective cognition', or (ii interaction with conspecifics can allow individuals to follow specific 'leaders', those experts with information particularly relevant to the decision at hand. However, a-priori, theory-based expectations about which of these decision rules should be preferred are lacking. Using a set of simple models, we present theoretical conditions (involving group size, and diversity of individual information under which groups should aggregate information, or follow an expert, when faced with a binary choice. We found that, in single-shot decisions, experts are almost always more accurate than the collective across a range of conditions. However, for repeated decisions - where individuals are able to consider the success of previous decision outcomes - the collective's aggregated information is almost always superior. The results improve our understanding of how social animals may process information and make decisions when accuracy is a key component of individual fitness, and provide a solid theoretical framework for future experimental tests where group size, diversity of individual information, and the repeatability of decisions can be measured and manipulated.

  18. Forward lunge as a functional performance test in ACL deficient subjects: test-retest reliability

    DEFF Research Database (Denmark)

    Alkjaer, Tine; Henriksen, Marius; Dyhre-Poulsen, Poul

    2009-01-01

    The forward lunge movement may be used as a functional performance test of anterior cruciate ligament (ACL) deficient and reconstructed subjects. The purposes were 1) to determine the test-retest reliability of a forward lunge in healthy subjects and 2) to determine the required numbers...... of repetitions necessary to yield satisfactory reliability. Nineteen healthy subjects performed four trials of a forward lunge on two different days. The movement time, impulses of the ground reaction forces (IFz, IFy), knee joint kinematics and dynamics during the forward lunge were calculated. The relative...... reliability was determined by calculation of Intraclass Correlation Coefficients (ICC). The IFz, IFy and the positive work of the knee extensors showed excellent reliability (ICC >0.75). All other variables demonstrated acceptable reliability (0.4>ICCreliability increased when more than...

  19. Earth-Base: testing the temporal congruency of paleontological collections and geologic maps of North America

    Science.gov (United States)

    Heim, N. A.; Kishor, P.; McClennen, M.; Peters, S. E.

    2012-12-01

    Free and open source software and data facilitate novel research by allowing geoscientists to quickly and easily bring together disparate data that have been independently collected for many different purposes. The Earth-Base project brings together several datasets using a common space-time framework that is managed and analyzed using open source software. Earth-Base currently draws on stratigraphic, paleontologic, tectonic, geodynamic, seismic, botanical, hydrologic and cartographic data. Furthermore, Earth-Base is powered by RESTful data services operating on top of PostgreSQL and MySQL databases and the R programming environment, making much of the functionality accessible to third-parties even though the detailed data schemas are unknown to them. We demonstrate the scientific potential of Earth-Base and other FOSS by comparing the stated age of fossil collections to the age of the bedrock upon which they are geolocated. This analysis makes use of web services for the Paleobiology Database (PaleoDB), Macrostrat, the 2005 Geologic Map of North America (Garrity et al. 2009) and geologic maps of the conterminous United States. This analysis is a way to quickly assess the accuracy of temporal and spatial congruence of the paleontologic and geologic map datasets. We find that 56.1% of the 52,593 PaleoDB collections have temporally consistent ages with the bedrock upon which they are located based on the Geologic Map of North America. Surprisingly, fossil collections within the conterminous United States are more consistently located on bedrock with congruent geological ages, even though the USA maps are spatially and temporally more precise. Approximately 57% of the 37,344 PaleoDB collections in the USA are located on similarly aged geologic map units. Increased accuracy is attributed to the lumping of Pliocene and Quaternary geologic map units along the Atlantic and Gulf coastal plains in the Geologic Map of North America. The abundant Pliocene fossil collections

  20. Historical estimates of external gamma exposure and collective external gamma exposure from testing at the Nevada Test Site. II. Test series after Hardtack II, 1958, and summary

    International Nuclear Information System (INIS)

    Anspaugh, L.R.; Ricker, Y.E.; Black, S.C.; Grossman, R.F.; Wheeler, D.L.; Church, B.W.; Quinn, V.E.

    1990-01-01

    The historical data on the cumulative individual external gamma exposures are tabulated for communities around the Nevada Test Site for the time periods of 1961 to the signing of the Limited Test Ban Treaty on 5 August 1963, and from then until 1975. The collective exposures during the two time periods are calculated to be 610 and 320 person-R, respectively. The total collective external gamma exposure from 1951 through 1975 for these communities s calculated to be 86,000 person-R. The area considered includes the countries of Clark, Lincoln, Nye, and White Pine in Nevada and the countries of Iron and Washington in Utah; inclusion of Salt Lake City would have substantially increased the calculated collective exposure because of the large population. The methods of calculation are reviewed. Also, the historical data on the assessment of dose via ingestion are reviewed with emphasis on the dose to the thyroid of infants living in St. George, UT, at the time of fallout from event HARRY on 19 May 1953

  1. Sealing performance test for main flange of pressure vessel of T2 test section in HENDEL

    International Nuclear Information System (INIS)

    Ioka, Ikuo; Inagaki, Yoshiyuki; Matsumoto, Kiminori; Kondou, Yasuo; Suzuki, Kunihiko; Miyamoto, Yoshiaki; Asami, Masanobu.

    1990-12-01

    A pressure vessel of T 2 test section in helium engineering demonstration loop (HENDEL) was fabricated to the same scale of the reactor pressure vessel made of 2(1/4)Cr-1Mo steel in high temperature engineering test reactor (HTTR). Also, the sealing structure of a main flange of pressure vessel in T 2 test section was composed of the double metal O-rings and Ω-seal which would be used in the sealing structure of HTTR. The sealing performance test for the main flange of the pressure vessel in T 2 test section was carried out to confirm the integrity of sealing structure of a main flange in HTTR. T 2 test section has been operated about 7700 hours in previous 18 cycles. The leakage of helium gas from inner metal O-ring was measured by the static pressurized process under the operating condition of HTTR (helium gas: 400degC, 40kg/cm 2 G, 4gk/s). The calculated leakage of helium gas was less than 9.6x10 -7 atm·cm 3 /sec. From the result, it is expected that the sealing structure of main flange in HTTR would maintain the leak tightness in the life. (author)

  2. Smell test predicts performance on delayed recall memory test in elderly with depression.

    Science.gov (United States)

    Scalco, Monica Z; Streiner, David L; Rewilak, Dmytro; Castel, Saulo; Van Reekum, Robert

    2009-04-01

    Elderly with depression are at increased risk for cognitive dysfunction and dementia. Smell tests are correlated with performance on cognitive tests in the elderly and therefore might serve as a screening test for cognitive impairment in depressed elderly. To assess the validity of the CC-SIT (Cross-Cultural Smell Identification Test) as a screening test for cognitive impairment in elderly with depression. Forty-one patients, aged 60 and over, were assessed with the CC-SIT and CVLT (California Verbal Learning Test) after 3 months treatment of a Major Depressive Episode (DSM-IV) at the Day Hospital for Depression, Baycrest. Patients already diagnosed with dementia, or other psychiatric and neurological disorders, were excluded. Receiver Operating Characteristics (ROC) analysis was applied to assess the CC-SIT's accuracy in identifying individuals with impairment (2 SD below the mean for age and education or less) on CVLT delayed recall trials. Forty-one patients (33 women and eight men) were assessed. Mean age was 76.8 (SD: 6.5), mean HRSD scores before treatment was 22.0 (SD: 5.1). Nine patients had impairment on CVLT delayed recall measures. The area under the ROC curve was 0.776 (95% CI = 0.617-0.936). Our results support the use of the CC-SIT as a screening tool for cognitive impairment among elderly with depression as an indicator for the need of a comprehensive neuropsychological evaluation. Replication with larger samples is necessary. (c) 2008 John Wiley & Sons, Ltd.

  3. Household Intertemporal Behaviour: A Collective Characterization and a Test of Commitment

    OpenAIRE

    Maurizio Mazzocco

    2007-01-01

    In this paper, a formal test of intra-household commitment is derived and performed. To that end, two models of household intertemporal behaviour are developed. In both models, household members are characterized by individual preferences. In the first formulation, household decisions are always on the ex ante Pareto frontier. In the second model, the assumption of intra-household commitment required by ex ante efficiency is relaxed. It is shown that the full-efficiency household Euler equati...

  4. Biodiesel production through hydrodynamic cavitation and performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Pal, Amit; Verma, Ashish; Kachhwaha, S.S.; Maji, S. [Department of Mechanical Engineering, Delhi College of Engineering, Bawana Road, Delhi 110042 (India)

    2010-03-15

    This paper presents the details of development of a biodiesel production test rig based on hydrodynamic cavitation followed by results of experimental investigation carried out on a four cylinder, direct injection water cooled diesel engine operating on diesel and biodiesel blend of Citrullus colocyntis (Thumba) oil. The experiment covers a wide range of engine rpm. Results show that biodiesel of Thumba oil produced through hydrodynamic cavitation technique can be used as an alternative fuel with better performance and lower emissions compared to diesel. The most significant conclusions are that (1) Biodiesel production through hydrodynamic cavitation technique seems to be a simple, efficient, time saving, eco-friendly and industrially viable process. (2) 30% biodiesel blend of Thumba oil shows relatively higher brake power, brake thermal efficiency, reduced bsfc and smoke opacity with favourable p-{theta} diagram as compared to diesel. (author)

  5. Performance Test of Alpha Spectrometry for Environmental Radioactivity Analysis

    International Nuclear Information System (INIS)

    Choi, Jung Youn; Yoon, Jong-Ho; Han, Ki-Tek; Ahn, Gil Hoon

    2015-01-01

    Environmental samples are analyzed by various methods such as, ICP-MS (inductively coupled plasma mass spectrometry), AMS (accelerator mass spectrometry) TIMS (thermal ionization mass spectrometry), HRGS (high resolution gamma spectrometry) and alpha /beta particle analysis. In this study, we will described the result of performance test using alpha spectrometry for analyzing environmental samples. Measurement data of the U activity using SRM based on extraction chromatography with UTEVA resin. It should be effective way to separate of uranium isotope for the measurement of alpha spectrometry. But, the result of this measurement data is higher than another recovery data. Also concentration of U data is lack of consistency. We leave out of consideration many effect of factors about influence in the experiment process. In the future work, we will try to reduce the step of experiment process and reflect the uncertainty factors

  6. Confirmation test on confinement performance of improved glove box

    International Nuclear Information System (INIS)

    Miura, S.; Kanazawa, J.; Nakajima, M.; Sakuno, K.; Miyata, H.

    1995-01-01

    Glove boxes are used at nuclear facilities to confine radioactive materials by ensuring a high level of airtightness and negative internal pressure. The allowable rate of air leakage is 0.1% vol/hr or less at the pre-service inspection. The negative pressure value is normally maintained at about -30 mm H 2 O. Structural strength and confinement reliability of glove boxes during earthquake are major concerns, and most important glove boxes are designed to withstand seismic class A events is Japan. This paper describes vibration tests done to confirm that improve large-sized glove boxes maintain their confinement performance and structural strength even during earthquake and that the design analysis methods used are appropriate. (author). 1 ref., 6 figs., 3 tabs

  7. Development and performance test of a solar tracker

    Energy Technology Data Exchange (ETDEWEB)

    Mahdi, T.H.; Hasib, Z.M. [Bangladesh Univ. of Engineering and Technology, Dhaka (Bangladesh). Dept. of Mechanical Engineering

    2010-07-01

    This paper discussed the development of a low-cost solar tracker device designed for use in developing countries. Expert control sensors and input-output interfaces were integrated with a tracking mechanism to increase the energy generation efficiency of the solar panel. Light sensing devices were used to automatically track the sun's rays. The controller sensors were integrated with the tracking mechanism. The control system was implemented on a microcontroller-based embedded system. A graphical user interface (GUI) was incorporated with a commercial software program in order to make the system more user-friendly. Performance tests demonstrated that the tracking system increases the amount of power that the solar panels could obtain. The efficiency of the panels increased by between 18 and 23 percent. Operators were able to control the movement of individual solar panels from a control room. The system also alerted operators of environmental damage to the panels. 12 refs., 2 tabs., 13 figs.

  8. Absolute Navigation Performance of the Orion Exploration Fight Test 1

    Science.gov (United States)

    Zanetti, Renato; Holt, Greg; Gay, Robert; D'Souza, Christopher; Sud, Jastesh

    2016-01-01

    Launched in December 2014 atop a Delta IV Heavy from the Kennedy Space Center, the Orion vehicle's Exploration Flight Test-1 (EFT-1) successfully completed the objective to stress the system by placing the un-crewed vehicle on a high-energy parabolic trajectory replicating conditions similar to those that would be experienced when returning from an asteroid or a lunar mission. Unique challenges associated with designing the navigation system for EFT-1 are presented with an emphasis on how redundancy and robustness influenced the architecture. Two Inertial Measurement Units (IMUs), one GPS receiver and three barometric altimeters (BALTs) comprise the navigation sensor suite. The sensor data is multiplexed using conventional integration techniques and the state estimate is refined by the GPS pseudorange and deltarange measurements in an Extended Kalman Filter (EKF) that employs UDU factorization. The performance of the navigation system during flight is presented to substantiate the design.

  9. Performance Evaluation and Robustness Testing of Advanced Oscilloscope Triggering Schemes

    Directory of Open Access Journals (Sweden)

    Shakeb A. KHAN

    2010-01-01

    Full Text Available In this paper, performance and robustness of two advanced oscilloscope triggering schemes is evaluated. The problem of time period measurement of complex waveforms can be solved using the algorithms, which utilize the associative memory network based weighted hamming distance (Whd and autocorrelation based techniques. Robustness of both the advanced techniques, are then evaluated by simulated addition of random noise of different levels to complex test signals waveforms, and minimum value of Whd (Whd min and peak value of coefficient of correlation(COCmax are computed over 10000 cycles of the selected test waveforms. The distance between mean value of second lowest value of Whd and Whd min and distance between second highest value of coefficient of correlation (COC and COC max are used as parameters to analyze the robustness of considered techniques. From the results, it is found that both the techniques are capable of producing trigger pulses efficiently; but correlation based technique is found to be better from robustness point of view.

  10. metrological performance improvement of a superconducting cable test station

    CERN Document Server

    Montenero, Giuseppe; Ballarino, Amalia

    The work presented in this PhD thesis concerns the metrological performance improvement of a superconducting cable test station based on superconducting transformers. The main cable’s parameter to be assessed –as a function of temperature and magnetic field– is the critical current, i.e. beyond this limit the phase transition to the normal state occurs. Ramping the current at levels in the order of the tens of kA can be achieved with superconducting transformers at moderate capital and operational cost. But, issues such as (i) accurate/precise measurements and (ii) monitoring of the secondary current during the device operation have to be addressed. In this regard, the goals of the thesis are the design, prototyping, and validation of a new cryogenic current transducer and effective monitoring system for test stations transformer-based. Among the available transducers for current sensing at room temperature, the DC current transformer (DCCT) provides measurement accuracy in the order of the hundreds of ...

  11. High School Students' Performance on Vandenberg's Mental Rotations Test: Art Ability, Gender, Activities, Academic Performance, Strategies, and Ease of Taking the Test.

    Science.gov (United States)

    Gurny, Helen Graham

    This study tested whether mental rotation performance of 186 high school students (80 males and 106 females) in grades 9 through 12 in art and nonart classes on Vandenbergs Mental Rotations test (S. Vandenberg and Kuse, 1978) was affected by gender, visual-spatial activities, strategies used while performing the test, and the ease of test taking.…

  12. Performance test of uninterruptible power system of PIEF

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Chae; Kim, Eun Ka; Chun, Yong Bum; Park, Dea Gyu; Chu, Yong Sun; Bae, Sang Min; Koo, Dae Seo

    1998-02-01

    Because of the special features of post-irradiation examination (PIE) facility to handle very high radioactive materials like spent nuclear fuels, the electric system of the facility was designed and constructed according to a very strict requirement which is applied to nuclear power plant. A safety grade of Class 1E was adopted in the power utility system of PIEF to guarantee stable power supply to the facility without any expected interruption. In order cope with a emergency condition like a power interruption of KEPCO, a emergency power supplying system consisting of a diesel generator (3-phase, 6600/440, 1,000 kW) and uninterruptibel power supply (UPS) system was installed in PIEF. UPS power is connected to the radiation monitoring system and several other main safety devices to assure of normal operations of them for not less than 30 minutes. According to the recommendations and regulations in nuclear law, a monthly and yearly regular inspection for the UPS and emergency power supplying system are performed. In this report, a brief description to establish self-inspection technology and procedures for the above mentioned electric power supplying system at PIEF, including a principle of operation, inspection scheme, trouble shooting, and performance test techniques were made. (author). 8 refs., 3 tabs., 4 figs.

  13. The Impact of Message Replication on the Performance of Opportunistic Networks for Sensed Data Collection

    Directory of Open Access Journals (Sweden)

    Tekenate E. Amah

    2017-11-01

    Full Text Available Opportunistic networks (OppNets provide a scalable solution for collecting delay‑tolerant data from sensors for their respective gateways. Portable handheld user devices contribute significantly to the scalability of OppNets since their number increases according to user population and they closely follow human movement patterns. Hence, OppNets for sensed data collection are characterised by high node population and degrees of spatial locality inherent to user movement. We study the impact of these characteristics on the performance of existing OppNet message replication techniques. Our findings reveal that the existing replication techniques are not specifically designed to cope with these characteristics. This raises concerns regarding excessive message transmission overhead and throughput degradations due to resource constraints and technological limitations associated with portable handheld user devices. Based on concepts derived from the study, we suggest design guidelines to augment existing message replication techniques. We also follow our design guidelines to propose a message replication technique, namely Locality Aware Replication (LARep. Simulation results show that LARep achieves better network performance under high node population and degrees of spatial locality as compared with existing techniques.

  14. Development and testing of a two stage granular filter to improve collection efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Rangan, R.S.; Prakash, S.G.; Chakravarti, S.; Rao, S.R.

    1999-07-01

    A circulating bed granular filter (CBGF) with a single filtration stage was tested with a PFB combustor in the Coal Research Facility of BHEL R and D in Hyderabad during the years 1993--95. Filter outlet dust loading varied between 20--50 mg/Nm{sup 3} for an inlet dust loading of 5--8 gms/Nm{sup 3}. The results were reported in Fluidized Bed Combustion-Volume 2, ASME 1995. Though the outlet consists of predominantly fine particulates below 2 microns, it is still beyond present day gas turbine specifications for particulate concentration. In order to enhance the collection efficiency, a two-stage granular filtration concept was evolved, wherein the filter depth is divided between two stages, accommodated in two separate vertically mounted units. The design also incorporates BHEL's scale-up concept of multiple parallel stages. The two-stage concept minimizes reentrainment of captured dust by providing clean granules in the upper stage, from where gases finally exit the filter. The design ensures that dusty gases come in contact with granules having a higher dust concentration at the bottom of the two-stage unit, where most of the cleaning is completed. A second filtration stage of cleaned granules is provided in the top unit (where the granules are returned to the system after dedusting) minimizing reentrainment. Tests were conducted to determine the optimum granule to dust ratio (G/D ratio) which decides the granule circulation rate required for the desired collection efficiency. The data brings out the importance of pre-separation and the limitation on inlet dust loading for any continuous system of granular filtration. Collection efficiencies obtained were much higher (outlet dust being 3--9 mg/Nm{sub 3}) than in the single stage filter tested earlier for similar dust loading at the inlet. The results indicate that two-stage granular filtration has a high potential for HTHT application with fewer risks as compared to other systems under development.

  15. Fast Flux Test Facility performance monitoring management information

    International Nuclear Information System (INIS)

    Newland, D.J.

    1987-11-01

    The purpose of this report is to provide performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the results for key performance indicators divided into two categories of ''overall'' and ''other''. The ''overall'' performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance

  16. Collective-efficacy as a mediator of the relationship of leaders' personality traits and team performance: A cross-level analysis.

    Science.gov (United States)

    Li, Xiaoshan; Zhou, Mingjie; Zhao, Na; Zhang, Shanshan; Zhang, Jianxin

    2015-06-01

    The relationship between a leader's personality and his team's performance has been established in organisational research, but the underlying process and mechanism responsible for this effect have not been fully explored. Both the traditional multiple linear regression and the multilevel structural equation model approaches were used in this study to test a proposed mediating model of subordinates' perception of collective efficacy between leader personality and team performance. The results show that the team leader's extraversion and conscientiousness personality traits were related positively to both the team-average (individual) perception of collective efficacy and team performance, and the collective efficacy mediated the relationship of the leader's personality traits and team performance. This study also discusses how Chinese cultural elements play a role in such a mediating model. © 2014 International Union of Psychological Science.

  17. How to Perform a Powder in Flexible Die Test

    DEFF Research Database (Denmark)

    Hancock, Mike; Nielsen, Morten Storgaard

    The “Powder in Flexible Die”-test, or PFD-test for short, proposes a new way of testing plastic properties of granular materials. The principal idea for the test originates from Dr. J.I Bech. The test has since been developed further and refined at IPL-DTU. The present work describes the equipment...

  18. Effects of solar collecting area and water flow rate on the performance of a sand bed solar collector

    International Nuclear Information System (INIS)

    Maganhar, A.L.; Memon, A.H.; Panhwar, M.I.

    2005-01-01

    The often discussed renewable sources of energy have been great interest to energy researchers and planners for quite some time. The primary of renewing all sources of energy is the sun. There have been two main problems not yet fully resolved. One is the large scale production of energy and other is the cost factor. In the present study, the cost factor is under consideration. In this regard a non-conventional solar collector using indigenous material (pit sand) as solar absorber is designed and manufactured. This paper presents the results of an investigation of the effect of solar collecting area and water flow rate on the performance of a pit sand bed solar collector especially in terms of rise in water temperature. Three pit sand solar collectors of area 1m/sup 2/ each were connected in series to enhance the collecting area and the system was tested for different flow rates. Experimental results proved that there was increase in water temperature with increase in solar collecting area an decreases in water temperature with increase in flow rate. (author)

  19. Study of the test method for prediction of air conditioning equipment seasonal performance

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, S.B.

    1980-05-01

    The test procedure, Method of Testing, Rating and Estimating the Seasonal Performance of Central Air-Conditioners and Heat Pumps Operating in the Cooling Mode, has been analyzed. The analysis of the test procedure incorporated two main functions: (1) to determine the validity of the test procedure; and (2) to determine if there are other alternate methods of obtaining the same results with less testing burden. Data were collected from industry and analyzed for any significant trends. Certain conclusions are drawn about the energy efficiency ratios, degradation coefficients and seasonal energy efficiency ratios. An error analysis was performed on the test procedure to determine the approximate amount of error when using this procedure. A semi-empirical model assuming a first order system response was developed to determine the factors that affect the part-load and cooling-load factors. The corresponding transient characteristics are then determined in terms of a single time constant. A thermostat demand cycle is used to determine the relationship between on-time and cycle-time. Recommendations are made regarding an alternate method being used to determine the seasonal energy efficiency ratio.

  20. Stress test of the nuclear power plants performed in Taiwan

    Energy Technology Data Exchange (ETDEWEB)

    Wu, C.H.; Teng, W.C.; Chang, S.; Chen, Y.B. [Atomic Energy Council, Taipei, Taiwan (China)

    2014-07-01

    In the wake of Japan's Fukushima Daiichi Nuclear Power Plants event, the Atomic Energy Council (AEC) has asked Taiwan's Nuclear Power Plant operator (TPC) to re-examine and re-evaluate the vulnerabilities of its nuclear units, and furthermore, take possible countermeasures against extreme natural disasters, including earthquake, tsunami and rock-and-mud slide. The evaluation process should be based on both within and beyond Design Basis Accidents, by reference to the actions recommended by the world nuclear authorities and groups, namely, IAEA, USNRC, NEI, ENSREG and WANO. Taiwan is a very densely populated region of the world. Furthermore, like Japan, due to its geophysical position, Taiwan is prone to large scale earthquakes, and although historically rare, Taiwan also faces the potential risk of tsunamis. AEC also asked TPC to perform the stress test following the specification given by WENRA (later ENSREG) and conducted in all the EU's nuclear reactors. After completion of the stress test for all the nuclear power plants, AEC was trying to have the reports peer reviewed by international organizations, as EU did. The OECD/NEA accepted AEC's request and formed a review team specific to the review of Taiwan's National Report for the Stress Test. There were 18 follow-up items after the NEA's review. Based on these items, AEC developed five orders to require TPC further enhancing their capabilities to cope with extreme natural hazards. The ENSREG also formed a nine-expert review team for Taiwan's Stress Test in response to AEC's request almost at the same time as the OECD/NEA. The ENSREG review team began their works in June 2013 by desktop review, and ended in early October 2013 by country visit to Taiwan. While the assessment of post-Fukushima evaluation reveals neither immediate nuclear safety concerns nor threats to the public health and safety, AEC requested that TPC focus on strengthening its re-evaluation on design

  1. Stress test of the nuclear power plants performed in Taiwan

    International Nuclear Information System (INIS)

    Wu, C.H.; Teng, W.C.; Chang, S.; Chen, Y.B.

    2014-01-01

    In the wake of Japan's Fukushima Daiichi Nuclear Power Plants event, the Atomic Energy Council (AEC) has asked Taiwan's Nuclear Power Plant operator (TPC) to re-examine and re-evaluate the vulnerabilities of its nuclear units, and furthermore, take possible countermeasures against extreme natural disasters, including earthquake, tsunami and rock-and-mud slide. The evaluation process should be based on both within and beyond Design Basis Accidents, by reference to the actions recommended by the world nuclear authorities and groups, namely, IAEA, USNRC, NEI, ENSREG and WANO. Taiwan is a very densely populated region of the world. Furthermore, like Japan, due to its geophysical position, Taiwan is prone to large scale earthquakes, and although historically rare, Taiwan also faces the potential risk of tsunamis. AEC also asked TPC to perform the stress test following the specification given by WENRA (later ENSREG) and conducted in all the EU's nuclear reactors. After completion of the stress test for all the nuclear power plants, AEC was trying to have the reports peer reviewed by international organizations, as EU did. The OECD/NEA accepted AEC's request and formed a review team specific to the review of Taiwan's National Report for the Stress Test. There were 18 follow-up items after the NEA's review. Based on these items, AEC developed five orders to require TPC further enhancing their capabilities to cope with extreme natural hazards. The ENSREG also formed a nine-expert review team for Taiwan's Stress Test in response to AEC's request almost at the same time as the OECD/NEA. The ENSREG review team began their works in June 2013 by desktop review, and ended in early October 2013 by country visit to Taiwan. While the assessment of post-Fukushima evaluation reveals neither immediate nuclear safety concerns nor threats to the public health and safety, AEC requested that TPC focus on strengthening its re-evaluation on design

  2. Prognostic durability of liver fibrosis tests and improvement in predictive performance for mortality by combining tests.

    Science.gov (United States)

    Bertrais, Sandrine; Boursier, Jérôme; Ducancelle, Alexandra; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Moal, Valérie; Calès, Paul

    2017-06-01

    There is currently no recommended time interval between noninvasive fibrosis measurements for monitoring chronic liver diseases. We determined how long a single liver fibrosis evaluation may accurately predict mortality, and assessed whether combining tests improves prognostic performance. We included 1559 patients with chronic liver disease and available baseline liver stiffness measurement (LSM) by Fibroscan, aspartate aminotransferase to platelet ratio index (APRI), FIB-4, Hepascore, and FibroMeter V2G . Median follow-up was 2.8 years during which 262 (16.8%) patients died, with 115 liver-related deaths. All fibrosis tests were able to predict mortality, although APRI (and FIB-4 for liver-related mortality) showed lower overall discriminative ability than the other tests (differences in Harrell's C-index: P fibrosis, 1 year in patients with significant fibrosis, and liver disease (MELD) score testing sets. In the training set, blood tests and LSM were independent predictors of all-cause mortality. The best-fit multivariate model included age, sex, LSM, and FibroMeter V2G with C-index = 0.834 (95% confidence interval, 0.803-0.862). The prognostic model for liver-related mortality included the same covariates with C-index = 0.868 (0.831-0.902). In the testing set, the multivariate models had higher prognostic accuracy than FibroMeter V2G or LSM alone for all-cause mortality and FibroMeter V2G alone for liver-related mortality. The prognostic durability of a single baseline fibrosis evaluation depends on the liver fibrosis level. Combining LSM with a blood fibrosis test improves mortality risk assessment. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  3. Development of testing techniques for mine fan performance

    Institute of Scientific and Technical Information of China (English)

    WU Zheng-yan; JIANG Shu-guang; PENG Dan-ren

    2006-01-01

    Three progressive stages of testing techniques are elaborated, which are entirely manual operating, taking separate instruments testing and computer program controlling. The testing method and principle are detailed based on the testing process for meteorological parameters, air pressure, air quality and rotating velocity. And every testing technique is analyzed. Finally, the technique outlook is viewed. All this plays a leading role in development of the testing techniques.

  4. Testing the performance of technical trading rules in the Chinese markets based on superior predictive test

    Science.gov (United States)

    Wang, Shan; Jiang, Zhi-Qiang; Li, Sai-Ping; Zhou, Wei-Xing

    2015-12-01

    Technical trading rules have a long history of being used by practitioners in financial markets. The profitable ability and efficiency of technical trading rules are yet controversial. In this paper, we test the performance of more than seven thousand traditional technical trading rules on the Shanghai Securities Composite Index (SSCI) from May 21, 1992 through June 30, 2013 and China Securities Index 300 (CSI 300) from April 8, 2005 through June 30, 2013 to check whether an effective trading strategy could be found by using the performance measurements based on the return and Sharpe ratio. To correct for the influence of the data-snooping effect, we adopt the Superior Predictive Ability test to evaluate if there exists a trading rule that can significantly outperform the benchmark. The result shows that for SSCI, technical trading rules offer significant profitability, while for CSI 300, this ability is lost. We further partition the SSCI into two sub-series and find that the efficiency of technical trading in sub-series, which have exactly the same spanning period as that of CSI 300, is severely weakened. By testing the trading rules on both indexes with a five-year moving window, we find that during the financial bubble from 2005 to 2007, the effectiveness of technical trading rules is greatly improved. This is consistent with the predictive ability of technical trading rules which appears when the market is less efficient.

  5. Basic considerations for the preparation of performance testing materials as related to performance evaluation acceptance criteria

    International Nuclear Information System (INIS)

    McCurdy, D.E.; Morton, J.S.

    2001-01-01

    The preparation of performance testing (PT) materials for environmental and radiobioassay applications involves the use of natural matrix materials containing the analyte of interest, the addition (spiking) of the analyte to a desired matrix (followed by blending for certain matrices) or a combination of the two. The distribution of the sample analyte concentration in a batch of PT samples will reflect the degree of heterogeneity of the analyte in the PT material and/or the reproducibility of the sample preparation process. Commercial and government implemented radioanalytical performance evaluation programs have a variety of acceptable performance criteria. The performance criteria should take into consideration many parameters related to the preparation of the PT materials including the within and between sample analyte heterogeneity, the accuracy of the quantification of an analyte in the PT material and to what 'known' value will a laboratory's result be compared. How sample preparation parameters affect the successful participation in performance evaluation (PE) programs having an acceptance criteria established as a percent difference from a 'known' value or in PE programs using other acceptance criteria, such as the guidance provided in ANSI N42.22 and N13.30 is discussed. (author)

  6. Fast Flux Test Facility performance monitoring management information: [Final report

    International Nuclear Information System (INIS)

    Newland, D.J.

    1987-09-01

    The purpose of this report is to provide management with performance data on key performance indicators for the month of July, 1987. This report contains the results for key performance indicators divided into two categories of ''overall'' and ''other''. The ''overall'' performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance

  7. Improving Test-Taking Performance of Secondary At-Risk Youth and Students with Disabilities

    Science.gov (United States)

    Banks, Tachelle; Eaton, India

    2014-01-01

    Preparing at-risk youth and students with mild disabilities for state and district tests is important for improving their test performance, and basic instruction in test preparation can significantly improve student test performance. The article defines noncognitive variables that adversely affect test-taker performance. The article also describes…

  8. A pilot solar water disinfecting system: performance analysis and testing

    Energy Technology Data Exchange (ETDEWEB)

    Saitoh, T.S.; El-Ghetany, H.H. [Tohoku University, Sendai (Japan). Dept. of Aeronautics and Space Engineering

    2002-07-01

    In most countries, contaminated water is the major cause of most water-borne diseases. Disinfection of water may be accomplished by a number of different physical-chemical treatments including direct application of thermal energy, chemical and filtration techniques. Solar energy also can be used effectively in this field because inactivation of microorganisms is done either by heating water to a disinfecting temperature or by exposing it to ultraviolet solar radiation. A pilot solar system for disinfecting contaminated water is designed, constructed and tested. Investigations are carried out to evaluate the performance of a wooden hot box solar facility as a solar disinfectant. Experimental data show that solar energy is viable for the disinfection process. A solar radiation model is presented and compared with the experimental data. A mathematical model of the solar disinfectant is also presented. The governing equations are solved numerically via the fourth-order Runge-Kutta method. The effects of environmental conditions (ambient temperature, wind speed, solar radiation, etc.) on the performance of the solar disinfectant are examined. Results showed that the system is affected by ambient temperature, wind speed, ultraviolet solar radiation intensity, the turbidity of the water, the quantity of water exposed, the contact area between the transparent water container in the solar disinfectant and the absorber plate as well as the geometrical parameters of the system. It is pointed out that for partially cloudy conditions with a low ambient temperature and high wind speeds, the thermal efficiency of the solar disinfectant is at a minimum. The use of solar energy for the disinfection process will increase the productivity of the system while completely eliminating the coliform group bacteria at the same time. (author)

  9. Power Performance Verification of a Wind Farm Using the Friedman's Test.

    Science.gov (United States)

    Hernandez, Wilmar; López-Presa, José Luis; Maldonado-Correa, Jorge L

    2016-06-03

    In this paper, a method of verification of the power performance of a wind farm is presented. This method is based on the Friedman's test, which is a nonparametric statistical inference technique, and it uses the information that is collected by the SCADA system from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. Here, the guaranteed power curve of the wind turbines is used as one more wind turbine of the wind farm under assessment, and a multiple comparison method is used to investigate differences between pairs of wind turbines with respect to their power performance. The proposed method says whether the power performance of the specific wind farm under assessment differs significantly from what would be expected, and it also allows wind farm owners to know whether their wind farm has either a perfect power performance or an acceptable power performance. Finally, the power performance verification of an actual wind farm is carried out. The results of the application of the proposed method showed that the power performance of the specific wind farm under assessment was acceptable.

  10. Power Performance Verification of a Wind Farm Using the Friedman’s Test

    Science.gov (United States)

    Hernandez, Wilmar; López-Presa, José Luis; Maldonado-Correa, Jorge L.

    2016-01-01

    In this paper, a method of verification of the power performance of a wind farm is presented. This method is based on the Friedman’s test, which is a nonparametric statistical inference technique, and it uses the information that is collected by the SCADA system from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. Here, the guaranteed power curve of the wind turbines is used as one more wind turbine of the wind farm under assessment, and a multiple comparison method is used to investigate differences between pairs of wind turbines with respect to their power performance. The proposed method says whether the power performance of the specific wind farm under assessment differs significantly from what would be expected, and it also allows wind farm owners to know whether their wind farm has either a perfect power performance or an acceptable power performance. Finally, the power performance verification of an actual wind farm is carried out. The results of the application of the proposed method showed that the power performance of the specific wind farm under assessment was acceptable. PMID:27271628

  11. Power Performance Verification of a Wind Farm Using the Friedman’s Test

    Directory of Open Access Journals (Sweden)

    Wilmar Hernandez

    2016-06-01

    Full Text Available In this paper, a method of verification of the power performance of a wind farm is presented. This method is based on the Friedman’s test, which is a nonparametric statistical inference technique, and it uses the information that is collected by the SCADA system from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. Here, the guaranteed power curve of the wind turbines is used as one more wind turbine of the wind farm under assessment, and a multiple comparison method is used to investigate differences between pairs of wind turbines with respect to their power performance. The proposed method says whether the power performance of the specific wind farm under assessment differs significantly from what would be expected, and it also allows wind farm owners to know whether their wind farm has either a perfect power performance or an acceptable power performance. Finally, the power performance verification of an actual wind farm is carried out. The results of the application of the proposed method showed that the power performance of the specific wind farm under assessment was acceptable.

  12. Performance and Health Test Procedure for Grid Energy Storage Systems: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Baggu, Murali M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Smith, Kandler A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Friedl, Andrew [San Diego Gas and Electric; Bialek, Thomas [San Diego Gas and Electric; Schimpe, Michael Robert [Technical University of Munich

    2017-07-27

    A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: Round-trip efficiency, Standby losses, Response time/accuracy, and Useable Energy/ State of Charge at different discharge/charge rates over the system's lifetime. The procedures are divided into Reference Performance Tests, which require the system to be put in a test mode and are to be conducted in intervals, and Real-time Monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.

  13. 40 CFR 60.2155 - May I conduct performance testing less often?

    Science.gov (United States)

    2010-07-01

    ... performance test. (c) If a performance test shows a deviation from an emission limitation for particulate... 40 Protection of Environment 6 2010-07-01 2010-07-01 false May I conduct performance testing less... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for...

  14. ''In situ'' electronic testing method of a neutron detector performance

    International Nuclear Information System (INIS)

    Gonzalez, J.M.; Levai, F.

    1987-01-01

    The method allows detection of any important change in the electrical characteristics of a neutron sensor channel. It checks the response signal produced by an electronic detector circuit when a pulse generator is connected as input signal in the high voltage supply. The electronic circuit compares the detector capacitance value, previously measured, against a reference value, which is adjusted in a window type comparator electronic circuit to detect any important degrading condition of the capacitance value in a detector-cable system. The ''in-situ'' electronic testing method of neutron detector performance has been verified in a laboratory atmosphere to be a potential method to detect any significant change in the capacitance value of a nuclear sensor and its connecting cable, also checking: detector disconnections, cable disconnections, length changes of the connecting cable, electric short-opened circuits in the sensor channel, and any electrical trouble in the detector-connector-cable system. The experimental practices were carried out by simulation of several electric changes in a nuclear sensor-cable system from a linear D.C. channel which measures reactor power during nuclear reactor operation. It was made at the Training Reactor Electronic Laboratory. The results and conclusions obtained at the Laboratory were proved, satisfactorily, in the Electronic Instrumentation of Budapest Technical University Training Reactor, Hungary

  15. System integration and performance of the EUV engineering test stand

    International Nuclear Information System (INIS)

    Tichenor, Daniel A.; Ray-Chaudhuri, Avijit K.; Replogle, William C.; Stulen, Richard H.; Kubiak, Glenn D.; Rockett, Paul D.; Klebanoff, Leonard E.; Jefferson, Karen L.; Leung, Alvin H.; Wronosky, John B.; Hale, Layton C.; Chapman, Henry N.; Taylor, John S.; Folta, James A.; Montcalm, Claude; Soufli, Regina; Spiller, Eberhard; Blaedel, Kenneth; Sommargren, Gary E.; Sweeney, Donald W.; Naulleau, Patrick; Goldberg, Kenneth A.; Gullikson, Eric M.; Bokor, Jeffrey; Batson, Phillip J.; Attwood, David T.; Jackson, Keith H.; Hector, Scott D.; Gwyn, Charles W.; Yan, Pei-Yang; Yan, P.

    2001-01-01

    The Engineering Test Stand (ETS) is a developmental lithography tool designed to demonstrate full-field EUV imaging and provide data for commercial-tool development. In the first phase of integration, currently in progress, the ETS is configured using a developmental projection system, while fabrication of an improved projection system proceeds in parallel. The optics in the second projection system have been fabricated to tighter specifications for improved resolution and reduced flare. The projection system is a 4-mirror, 4x-reduction, ring-field design having a numeral aperture of 0.1, which supports 70 nm resolution at a k 1 of 0.52. The illuminator produces 13.4 nm radiation from a laser-produced plasma, directs the radiation onto an arc-shaped field of view, and provides an effective fill factor at the pupil plane of 0.7. The ETS is designed for full-field images in step-and-scan mode using vacuum-compatible, magnetically levitated, scanning stages. This paper describes system performance observed during the first phase of integration, including static resist images of 100 nm isolated and dense features

  16. Enhancement of Tokamak Fusion Test Reactor performance by lithium conditioning

    International Nuclear Information System (INIS)

    Mansfield, D.K.; Hill, K.W.; Strachan, J.D.; Bell, M.G.; Scott, S.D.; Budny, R.; Marmar, E.S.; Snipes, J.A.; Terry, J.L.; Batha, S.; Bell, R.E.; Bitter, M.; Bush, C.E.; Chang, Z.; Darrow, D.S.; Ernst, D.; Fredrickson, E.; Grek, B.; Herrmann, H.W.; Janos, A.; Jassby, D.L.; Jobes, F.C.; Johnson, D.W.; Johnson, L.C.; Levinton, F.M.; Mikkelsen, D.R.; Mueller, D.; Owens, D.K.; Park, H.; Ramsey, A.T.; Roquemore, A.L.; Skinner, C.H.; Stevenson, T.; Stratton, B.C.; Synakowski, E.; Taylor, G.; von Halle, A.; von Goeler, S.; Wong, K.L.; Zweben, S.J.

    1996-01-01

    Wall conditioning in the Tokamak Fusion Test Reactor (TFTR) [K. M. McGuire et al., Phys. Plasmas 2, 2176 (1995)] by injection of lithium pellets into the plasma has resulted in large improvements in deuterium endash tritium fusion power production (up to 10.7 MW), the Lawson triple product (up to 10 21 m -3 s keV), and energy confinement time (up to 330 ms). The maximum plasma current for access to high-performance supershots has been increased from 1.9 to 2.7 MA, leading to stable operation at plasma stored energy values greater than 5 MJ. The amount of lithium on the limiter and the effectiveness of its action are maximized through (1) distributing the Li over the limiter surface by injection of four Li pellets into Ohmic plasmas of increasing major and minor radius, and (2) injection of four Li pellets into the Ohmic phase of supershot discharges before neutral-beam heating is begun. copyright 1996 American Institute of Physics

  17. Thermal performance test of the hot gas ducts of HENDEL

    International Nuclear Information System (INIS)

    Hishida, M.; Kunitomi, K.; Ioka, I.; Umenishi, K.; Tanaka, T.; Shimomura, H.; Sanokawa, K.

    1984-01-01

    A hot gas duct provided with internal thermal insulation is to be used for high-temperature gas-cooled reactors (HTGR). This type of hot gas duct has not been used so far in industrial facilities, and only a couple of tests on such a large-scale model of a hot gas duct have been conducted. The present report deals with the results of the thermal performance of the single tube type hot gas ducts which are installed as parts of a helium engineering demonstration loop (HENDEL). Uniform temperature and heat flux distribution at the surface of the duct were observed, the experimental correlations being obtained for the effective thermal conductivity of the internal thermal insulation layer. The measured temperature distribution of the pressure tube was in good agreement with the calculation by a TRUMP heat transfer computer code. The temperature distribution of the inner tube of the co-axial hot gas duct was evaluated and no hot spot was detected. These results would be very valuable for the design and development of HTGR. (orig.)

  18. The 5-choice continuous performance test: evidence for a translational test of vigilance for mice.

    Directory of Open Access Journals (Sweden)

    Jared W Young

    Full Text Available Attentional dysfunction is related to functional disability in patients with neuropsychiatric disorders such as schizophrenia, bipolar disorder, and Alzheimer's disease. Indeed, sustained attention/vigilance is among the leading targets for new medications designed to improve cognition in schizophrenia. Although vigilance is assessed frequently using the continuous performance test (CPT in humans, few tests specifically assess vigilance in rodents.We describe the 5-choice CPT (5C-CPT, an elaboration of the 5-choice serial reaction (5CSR task that includes non-signal trials, thus mimicking task parameters of human CPTs that use signal and non-signal events to assess vigilance. The performances of C57BL/6J and DBA/2J mice were assessed in the 5C-CPT to determine whether this task could differentiate between strains. C57BL/6J mice were also trained in the 5CSR task and a simple reaction-time (RT task involving only one choice (1CRT task. We hypothesized that: 1 C57BL/6J performance would be superior to DBA/2J mice in the 5C-CPT as measured by the sensitivity index measure from signal detection theory; 2 a vigilance decrement would be observed in both strains; and 3 RTs would increase across tasks with increased attentional load (1CRT task<5CSR task<5C-CPT.C57BL/6J mice exhibited superior SI levels compared to DBA/2J mice, but with no difference in accuracy. A vigilance decrement was observed in both strains, which was more pronounced in DBA/2J mice and unaffected by response bias. Finally, we observed increased RTs with increased attentional load, such that 1CRT task<5CSR task<5C-CPT, consistent with human performance in simple RT, choice RT, and CPT tasks. Thus we have demonstrated construct validity for the 5C-CPT as a measure of vigilance that is analogous to human CPT studies.

  19. Organizational climate configurations: relationships to collective attitudes, customer satisfaction, and financial performance.

    Science.gov (United States)

    Schulte, Mathis; Ostroff, Cheri; Shmulyian, Svetlana; Kinicki, Angelo

    2009-05-01

    Research on organizational climate has tended to focus on independent dimensions of climate rather than studying the total social context as configurations of multiple climate dimensions. The authors examined relationships between configurations of unit-level climate dimensions and organizational outcomes. Three profile characteristics represented climate configurations: (1) elevation, or the mean score across climate dimensions; (2) variability, or the extent to which scores across dimensions vary; and (3) shape, or the pattern of the dimensions. Across 2 studies (1,120 employees in 120 bank branches and 4,317 employees in 86 food distribution stores), results indicated that elevation was related to collective employee attitudes and service perceptions, while shape was related to customer satisfaction and financial performance. With respect to profile variability, results were mixed. The discussion focuses on future directions for taking a configural approach to organizational climate. (c) 2009 APA, all rights reserved.

  20. BWR spent fuel storage cask performance test. Volume 1. Cask handling experience and decay heat, heat transfer, and shielding data

    International Nuclear Information System (INIS)

    McKinnon, M.A.; Doman, J.W.; Tanner, J.E.; Guenther, R.J.; Creer, J.M.; King, C.E.

    1986-02-01

    This report documents a heat transfer and shielding performance test conducted on a Ridihalgh, Eggers and Associates REA 2023 boiling water reactor (BWR) spent fuel storage cask. The testing effort consisted of three parts: pretest preparations, performance testing, and post-test activities. Pretest preparations included conducting cask handling dry runs and characterizing BWR spent fuel assemblies from Nebraska Public Power District's Cooper Nuclear Station. The performance test matrix included 14 runs consisting of two loadings, two cask orientations, and three backfill environments. Post-test activities included calorimetry and axial radiation scans of selected fuel assemblies, in-basin sipping of each assembly, crud collection, video and photographic scans, and decontamination of the cask interior and exterior

  1. Synthetic and Enhanced Vision Systems for NextGen (SEVS) Simulation and Flight Test Performance Evaluation

    Science.gov (United States)

    Shelton, Kevin J.; Kramer, Lynda J.; Ellis,Kyle K.; Rehfeld, Sherri A.

    2012-01-01

    The Synthetic and Enhanced Vision Systems for NextGen (SEVS) simulation and flight tests are jointly sponsored by NASA's Aviation Safety Program, Vehicle Systems Safety Technology project and the Federal Aviation Administration (FAA). The flight tests were conducted by a team of Honeywell, Gulfstream Aerospace Corporation and NASA personnel with the goal of obtaining pilot-in-the-loop test data for flight validation, verification, and demonstration of selected SEVS operational and system-level performance capabilities. Nine test flights (38 flight hours) were conducted over the summer and fall of 2011. The evaluations were flown in Gulfstream.s G450 flight test aircraft outfitted with the SEVS technology under very low visibility instrument meteorological conditions. Evaluation pilots flew 108 approaches in low visibility weather conditions (600 ft to 2400 ft visibility) into various airports from Louisiana to Maine. In-situ flight performance and subjective workload and acceptability data were collected in collaboration with ground simulation studies at LaRC.s Research Flight Deck simulator.

  2. Pad-weighing test performed with standardized bladder volume

    DEFF Research Database (Denmark)

    Lose, G; Rosenkilde, P; Gammelgaard, J

    1988-01-01

    The result of the one-hour pad-weighing test proposed by the International Continence Society has been demonstrated to depend on the urine load during the test. To increase reproducibility of the pad-weighing test by minimizing the influence of variation in urine load the test was done with a sta...... to +/- 24 g between two tests. It is concluded that this setup (i.e., standardized bladder volume) of the one-hour pad-weighing test allows for a more reliable assessment of urinary incontinence for quantitative purposes....... with a standardized bladder volume (50% of the cystometric bladder capacity). Twenty-five female patients with stress or mixed incontinence underwent two separate tests. Test-retest results were highly correlated (r = 0.97, p less than 0.001). Nonetheless, analysis of test-retest differences revealed a variation up...

  3. Tigecycline activity tested against 26,474 bloodstream infection isolates: a collection from 6 continents.

    Science.gov (United States)

    Sader, Helio S; Jones, Ronald N; Stilwell, Matthew G; Dowzicky, Michael J; Fritsche, Thomas R

    2005-07-01

    The activity of tigecycline (formerly GAR936), a novel glycylcycline, was tested against recent bloodstream infection (BSI) pathogen isolates from 6 continents. Frequency of clinical occurrence of these pathogens was determined and their antibiograms assessed using reference broth microdilution methods. A total of 26474 strains were tested for tigecycline susceptibility according to the Clinical and Laboratory Standards Institute (formerly the National Committee for Clinical Laboratory Standards) by the M7-A6 guidelines with interpretations from M100-S15 and the package insert. The rank order of pathogens was Staphylococcus aureus (33.1%), Escherichia coli (14.0%), coagulase-negative staphylococci (13.5%), Enterococcus spp. (12.3%), Klebsiella spp. (5.7%), Pseudomonas aeruginosa (4.2%), Enterobacter spp. (3.0%), beta-hemolytic streptococci (2.9%), Streptococcus pneumoniae (2.3%), and viridans group streptococci (1.4%). Tigecycline exhibited a broader spectrum of activity against BSI isolates when compared to ciprofloxacin, tetracycline, aminoglycosides, and many beta-lactams (imipenem). Tigecycline was highly active against most pathogens tested, including staphylococci (MIC(90), 0.5 microg/mL), enterococci (MIC90, 0.25 microg/mL), streptococci (MIC(90), < or =0.12 microg/mL), Escherichia coli (MIC90, 0.25 microg/mL), Klebsiella spp. (MIC90, 1 mmicrog/mL), and Enterobacter spp. (MIC(90), 2 mmicrog/mL), but showed limited inhibition of Pseudomonas aeruginosa (MIC90, 16 microg/mL) and indole-positive or indole-negative Proteae (MIC90, 4-8 microg/mL). In summary, tigecycline exhibited a wide spectrum of antimicrobial potency versus BSI isolates collected worldwide. Serious infections in nosocomial environments should benefit from tigecycline use among the investigational phase 3 agents focused toward resistant strains.

  4. The relative performance of bivariate causality tests in small samples

    NARCIS (Netherlands)

    Bult, J..R.; Leeflang, P.S.H.; Wittink, D.R.

    1997-01-01

    Causality tests have been applied to establish directional effects and to reduce the set of potential predictors, For the latter type of application only bivariate tests can be used, In this study we compare bivariate causality tests. Although the problem addressed is general and could benefit

  5. Test Code Quality and Its Relation to Issue Handling Performance

    NARCIS (Netherlands)

    Athanasiou, D.; Nugroho, A.; Visser, J.; Zaidman, A.

    2014-01-01

    Automated testing is a basic principle of agile development. Its benefits include early defect detection, defect cause localization and removal of fear to apply changes to the code. Therefore, maintaining high quality test code is essential. This study introduces a model that assesses test code

  6. Performance, usability and comparison of two versions of a new macular vision test: the handheld Radial Shape Discrimination test

    Directory of Open Access Journals (Sweden)

    Jae Y. Ku

    2016-11-01

    Full Text Available Background Central vision, critical for everyday tasks such as reading and driving, is impacted by age-related changes in the eye and by diseases such as age-related macular degeneration. The detection of changes in macular function is therefore important. The Radial Shape Discrimination (RSD test measures the threshold at which distortions in a radial frequency pattern can be detected and there is evidence that it is more sensitive to macular pathology than visual acuity (VA. It also provides a more quantitative measure of macular function than the commonly available Amsler grid. Recently, handheld versions of the test (hRSD in which stimuli are presented on mobile devices (e.g., Apple iPod Touch, iPhone have been developed. We investigated the characteristics of the hRSD test in healthy participants. Methods Data were collected using both three-alternative forced choice (3AFC and 4AFC versions of the hRSD test, presented on an Apple iPod Touch. For the 3AFC version, data from a single test session were available for 186 (72 male; mean ± SD age 42 ± 17y; range 16–90y healthy participants. Test-retest data were available for subgroups of participants (intra-session: N = 74; tests approximately 2 months apart: N = 30; tests 39 months apart: N = 15. The 3AFC and 4AFC versions were directly compared in 106 participants who also completed a usability questionnaire. Distance and near VA and Pelli Robson Contrast Sensitivity (CS data were collected and undilated fundoscopy performed on the majority of participants. Results Mean (±SD 3AFC hRSD threshold was −0.77 ± 0.14 logMAR, and was statistically significantly correlated with age (Pearson r = 0.35; p < 0.001. The linear regression of hRSD threshold on age had a slope of +0.0026 compared to +0.0051 for near VA (which also correlated with age: r = 0.51; p < 0.001. There were no statistically significant differences in hRSD thresholds for any of the test-retest subgroups. We

  7. Neutron detection performance of silicon carbide and diamond detectors with incomplete charge collection properties

    Energy Technology Data Exchange (ETDEWEB)

    Hodgson, M., E-mail: michael.hodgson@becq.co.uk [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Lohstroh, A.; Sellin, P. [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Thomas, D. [NPL, Teddington TW11 0LW (United Kingdom)

    2017-03-01

    The benefits of neutron detection and spectroscopy with carbon based, wide band gap, semiconductor detectors have previously been discussed within the literature. However, at the time of writing there are still limitations with these detectors related to availability, cost, size and perceived quality. This study demonstrates that lower quality materials—indicated by lower charge collection efficiency (CCE), poor resolution and polarisation effect—available at wafer scale and lower cost, can fulfil requirements for fast neutron detection and spectroscopy for fluxes over several orders of magnitude, where only coarse energy discrimination is required. In this study, a single crystal diamond detector (D-SC, with 100% CCE), a polycrystalline diamond (D-PC, with ≈4% CCE) and semi-insulating silicon carbide (SiC-SI, with ≈35% CCE) have been compared for alpha and fast neutron performance. All detectors demonstrated alpha induced polarisation effects in the form of a change of both energy peak position and count rate with irradiation time. Despite these operational issues the ability to detect fast neutrons and distinguish neutron energies was observed. This performance was demonstrated over a wide dynamic range (500–40,000 neutrons/s), with neutron induced polarisation being demonstrated in D-PC and SiC-SI at high fluxes.

  8. Performance tests of external moderators of a PGNAA setup

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Fazal-ur-Rehman,; Al-Jarallah, M.I.; Abu-Jarad, F.; Maslehuddin, M.

    2003-01-01

    Performance tests of external cylindrical moderators of an accelerator-based prompt gamma ray neutron activation analysis (PGNAA) setup have been carried out through thermal neutrons and prompt γ-ray yield measurements. The PGNAA setup is to be used for analysis of cement samples. This study was conducted to investigate the effects of geometry of cylindrical moderator on yield of thermal neutrons and prompt γ-rays for two different types of moderator assemblies. One of the moderators was to be used with a small sample and the other to be used with a large sample. Fast and thermal neutron yield was measured inside the sample volume as a function of the front moderator thickness as well as sample length. Neutron yield measurement was carried out at the King Fahd University of Petroleum and Minerals 350 keV pulsed beam accelerator using nuclear track detectors. The pulsed 200 keV deuteron beam with 5 ns pulse width and 31.25 kHz frequency was used to produce 2.8 MeV neutrons via D(d,n) reaction. Neutron yield measurements showed that the large sample moderator has a smaller yield of thermal neutrons as compared to the small sample moderator, which is in complete agreement with the results of Monte Carlo yield calculations of the thermal and fast neutrons from both the moderators. Finally, the prompt γ-ray yield from a Portland cement sample was measured using the two moderators and was compared with each other. As predicted by Monte Carlo simulations, in spite of a smaller yield of thermal neutrons, the large sample moderator has a higher yield of prompt γ-rays

  9. Performance tests of external moderators of a PGNAA setup

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman,; Al-Jarallah, M.I.; Abu-Jarad, F.; Maslehuddin, M

    2003-01-01

    Performance tests of external cylindrical moderators of an accelerator-based prompt gamma ray neutron activation analysis (PGNAA) setup have been carried out through thermal neutrons and prompt {gamma}-ray yield measurements. The PGNAA setup is to be used for analysis of cement samples. This study was conducted to investigate the effects of geometry of cylindrical moderator on yield of thermal neutrons and prompt {gamma}-rays for two different types of moderator assemblies. One of the moderators was to be used with a small sample and the other to be used with a large sample. Fast and thermal neutron yield was measured inside the sample volume as a function of the front moderator thickness as well as sample length. Neutron yield measurement was carried out at the King Fahd University of Petroleum and Minerals 350 keV pulsed beam accelerator using nuclear track detectors. The pulsed 200 keV deuteron beam with 5 ns pulse width and 31.25 kHz frequency was used to produce 2.8 MeV neutrons via D(d,n) reaction. Neutron yield measurements showed that the large sample moderator has a smaller yield of thermal neutrons as compared to the small sample moderator, which is in complete agreement with the results of Monte Carlo yield calculations of the thermal and fast neutrons from both the moderators. Finally, the prompt {gamma}-ray yield from a Portland cement sample was measured using the two moderators and was compared with each other. As predicted by Monte Carlo simulations, in spite of a smaller yield of thermal neutrons, the large sample moderator has a higher yield of prompt {gamma}-rays.

  10. The Physical Clogging of the Landfill Leachate Collection System in China: Based on Filtration Test and Numerical Modelling

    Directory of Open Access Journals (Sweden)

    Yili Liu

    2018-02-01

    Full Text Available Clogging of the leachate collection system (LCS has been a common operation problem in municipal solid waste (MSW landfills in China, which can result in high water levels that threaten the safety of landfill operations. To determine the cause of failure in an LCS, raw leachate from a municipal solid waste transfer station was collected and the high content of particulate matter was characterized. Based on the parameters obtained in a filtration test, a numerical simulation was performed to estimate the influence of particle deposition on drainage system clogging. The results showed that LCSs were confronted with the risk of clogging due to the deposition of particulate matter resulting from the higher concentration of total suspended solids (TSS level > 2200 mg L−1 and larger particle size (>30% TSS particles > 15 μm in the leachate. On one hand, the non-woven geotextile, as the upper layer of the LCS, retained most particulate matter of large diameters, reducing its hydraulic conductivity to approximately 10−8 to 10−9 m s−1 after 1–2 years of operation and perching significant leachate above it (0.6–0.7 m. On the other hand, the geotextile prevented the gravel layer from physically clogging and minimized the leachate head above the bottom liner. Therefore, the role of geotextile should be balanced to optimize the LCS in MSW landfills in China.

  11. Pathogenic bacteria and heavy metals toxicity assessments in evaluating unpasteurized raw milk quality through biochemical tests collected from dairy cows

    Directory of Open Access Journals (Sweden)

    Hamid Iqbal

    2016-11-01

    Full Text Available Objective: To evaluate the hygienic quality by determining the presence of predominant pathogenic microbial contaminants (contagious or environmental and indiscriminate heavy metals contained in unpasteurized milk samples collected from cattle specie of cow. Methods: Raw milk samples were collected in October, 2014 from different regions of District Kohat, Khyber Pakhtunkhwa, Pakistan and cultured on the selective media plates according to the manufacturer instructions to observe pathogenic microbial flora and confirm it with relevant biochemical tests to specify bacterial specie. Results: Milk samples analyzed on MacConkey and nutrient agar media were found contaminated mostly with coliform, Staphylococcus aureus, Enterobacter aerogenes and Proteus vulgaris. Similarly, result of the heavy metals analysis performed using atomic absorption spectrophotometer flame photometry showed that raw milk contains heavy metals residues of lead and cadmium contents at higher levels while copper, zinc and chromium were observed lower than permissible limits whereas manganese within specified recommended values. Conclusions: Microbial contamination of milk and toxic metals is mainly accredited to the scrupulous unhygienic measures during processing of milk exhibiting a wide array of hazardous impacts on human health.

  12. Acting in solidarity : Testing an extended dual pathway model of collective action by bystander group members

    NARCIS (Netherlands)

    Saab, Rim; Tausch, Nicole; Spears, Russell; Cheung, Wing-Yee

    We examined predictors of collective action among bystander group members in solidarity with a disadvantaged group by extending the dual pathway model of collective action, which proposes one efficacy-based and one emotion-based path to collective action (Van Zomeren, Spears, Fischer, & Leach,

  13. Evaluation of operational, economic, and environmental performance of mixed and selective collection of municipal solid waste: Porto case study.

    Science.gov (United States)

    Teixeira, Carlos A; Russo, Mário; Matos, Cristina; Bentes, Isabel

    2014-12-01

    This article describes an accurate methodology for an operational, economic, and environmental assessment of municipal solid waste collection. The proposed methodological tool uses key performance indicators to evaluate independent operational and economic efficiency and performance of municipal solid waste collection practices. These key performance indicators are then used in life cycle inventories and life cycle impact assessment. Finally, the life cycle assessment environmental profiles provide the environmental assessment. We also report a successful application of this tool through a case study in the Portuguese city of Porto. Preliminary results demonstrate the applicability of the methodological tool to real cases. Some of the findings focus a significant difference between average mixed and selective collection effective distance (2.14 km t(-1); 16.12 km t(-1)), fuel consumption (3.96 L t(-1); 15.37 L t(-1)), crew productivity (0.98 t h(-1) worker(-1); 0.23 t h(-1) worker(-1)), cost (45.90 € t(-1); 241.20 € t(-1)), and global warming impact (19.95 kg CO2eq t(-1); 57.47 kg CO2eq t(-1)). Preliminary results consistently indicate: (a) higher global performance of mixed collection as compared with selective collection; (b) dependency of collection performance, even in urban areas, on the waste generation rate and density; (c) the decline of selective collection performances with decreasing source-separated material density and recycling collection rate; and (d) that the main threats to collection route efficiency are the extensive collection distances, high fuel consumption vehicles, and reduced crew productivity. © The Author(s) 2014.

  14. Cavitating Propeller Performance in Inclined Shaft Conditions with OpenFOAM: PPTC 2015 Test Case

    Science.gov (United States)

    Gaggero, Stefano; Villa, Diego

    2018-05-01

    In this paper, we present our analysis of the non-cavitating and cavitating unsteady performances of the Potsdam Propeller Test Case (PPTC) in oblique flow. For our calculations, we used the Reynolds-averaged Navier-Stokes equation (RANSE) solver from the open-source OpenFOAM libraries. We selected the homogeneous mixture approach to solve for multiphase flow with phase change, using the volume of fluid (VoF) approach to solve the multiphase flow and modeling the mass transfer between vapor and water with the Schnerr-Sauer model. Comparing the model results with the experimental measurements collected during the Second Workshop on Cavitation and Propeller Performance - SMP'15 enabled our assessment of the reliability of the open-source calculations. Comparisons with the numerical data collected during the workshop enabled further analysis of the reliability of different flow solvers from which we produced an overview of recommended guidelines (mesh arrangements and solver setups) for accurate numerical prediction even in off-design conditions. Lastly, we propose a number of calculations using the boundary element method developed at the University of Genoa for assessing the reliability of this dated but still widely adopted approach for design and optimization in the preliminary stages of very demanding test cases.

  15. Modified performance test of vented lead acid batteries for stationary applications

    International Nuclear Information System (INIS)

    Uhlir, K.W.; Fletcher, R.J.

    1995-01-01

    The concept of a modified performance test for vented lead acid batteries in stationary applications has been developed by the IEEE Battery Working Group. The modified performance test is defined as a test in the ''as found'' condition of the battery capacity and its ability to provide a high rate, short duration load (usually the highest rate of the duty cycle) that will confirm the battery's ability to meet the critical period of the load duty cycle, in addition to determining its percentage of rated capacity. This paper will begin by reviewing performance and service test requirements and concerns associated with both types of tests. The paper will then discuss the rationale for developing a modified performance test along with the benefits that can be derived from performing a modified performance test in lieu of a capacity test and/or a service test. The paper will conclude with an example on how to apply a modified performance test and test acceptance criteria

  16. Effects of Collective Efficacy, Teamwork Attitudes, and Experience on Group Project Performance: Comparisons between 2 Food Science Courses

    Science.gov (United States)

    McLeod, Poppy Lauretta; Orta-Ramirez, Alicia

    2018-01-01

    The relationship between past teamwork and task-related experiences, attitude toward teamwork, collective efficacy, and task performance among undergraduates (N = 298) assigned to group projects (N = 48) in 2 different Food Science courses was examined. The results of survey data collected at the beginning and end of the projects showed that past…

  17. Performance test of SAUNA xenon mobile sampling system

    International Nuclear Information System (INIS)

    Hu Dan; Yang Bin; Yang Weigeng; Jia Huaimao; Wang Shilian; Li Qi; Zhao Yungang; Fan Yuanqing; Chen Zhanying; Chang Yinzhong; Liu Shujiang; Zhang Xinjun; Wang Jun

    2011-01-01

    In this article, the structure and basic functions of SAUNA noble gas xenon mobile sampling system are introduced. The sampling capability of this system is about 2.2 mL per day, as a result from a 684-h operation. The system can be transported to designated locations conveniently to collect xenon sample for routine or emergency environment monitoring. (authors)

  18. A Low Cost System for Testing and Monitoring the Performance of Photovoltaic Module

    Directory of Open Access Journals (Sweden)

    POPESCU, V.

    2013-11-01

    Full Text Available The purpose of this paper is to develop a low cost system for testing and monitoring the performance of PV modules in outdoor conditions. In order to do this, we improved and adapted another measuring system. This system was developed by us and enables us to ensure the performance of the PV module through testing and monitoring, as well as saving collected data to a database. This database can be accessed through a graphical interface on a laptop connected to the system using serial interface. The error sources of this system are reduced to minimum because of human operators interfering with the system only through the graphical user interface. The Two Diode Model with series and parallel resistances was used to estimate the parameters of the electrical equivalent circuit for the PV module. This model will be simulated in CASPOC 2009. The performances of PV module were obtained in outdoor conditions and were saved to the database. They will be compared with the performances obtained through simulation, to prove the efficiency of the model.

  19. Performance Tests of a Permeation Sensor for Test Blanket Modules Using Liquid Metal

    International Nuclear Information System (INIS)

    Choi, B. G.; Lee, D. W.; Lee, E. H.; Yoon, J. S.; Kim, S. K.; Shin, K. I.; Jin, H. G.

    2013-01-01

    The tritium extraction from a breeder is one of the key technologies and its methods have been investigated. For developing the tritium extraction methods and evaluating the amount of tritium in the system, a reliable and correct sensor is required to measure the hydrogen concentration in liquid metal breeder. There are several researches for developing the sensors in the ITER participants and especially, EU has developed the permeation sensors trying to selecting materials with low Serviette's constant (solubility) and high hydrogen diffusivity coefficient. However, EU's response time is still too long time about tens of minutes to measure the tritium concentration in the online system. We have been performing the preliminary tests with designed and fabricated sensors to solve the late response of sensor. However, we could not continue the tests because of the membrane's oxidation (pure Fe) and the difficulty of welding nonferrous metals. In present study, a permeation sensor made of vacuum flanges with a porous plate inside is proposed not only to eliminate the difficulty of the fabrication but to optimize the performance of sensor. The permeation sensor to measure the hydrogen isotopes in liquid metal breeder has been proposed and evaluated to overcome the limitation of a long response time for various shapes and materials. We found that the previous sensors have limitation; the oxidation problems (pure Fe) and the difficulty in welding (nonferrous metals). Therefore we proposed a permeation sensor with the vacuum flanges filled with porous disks to eliminate the problems. By using the CF flanges, the problem caused by welding is removed. But the permeable response time of sensors took a long time to reach the pressure equivalent

  20. 49 CFR Appendix H to Part 40 - DOT Drug and Alcohol Testing Management Information System (MIS) Data Collection Form

    Science.gov (United States)

    2010-10-01

    ..., App. H Appendix H to Part 40—DOT Drug and Alcohol Testing Management Information System (MIS) Data... 49 Transportation 1 2010-10-01 2010-10-01 false DOT Drug and Alcohol Testing Management Information System (MIS) Data Collection Form H Appendix H to Part 40 Transportation Office of the Secretary...