WorldWideScience

Sample records for performance test consisted

  1. Glass consistency and glass performance

    International Nuclear Information System (INIS)

    Plodinec, M.J.; Ramsey, W.G.

    1994-01-01

    Glass produced by the Defense Waste Processing Facility (DWPF) will have to consistently be more durable than a benchmark glass (evaluated using a short-term leach test), with high confidence. The DWPF has developed a Glass Product Control Program to comply with this specification. However, it is not clear what relevance product consistency has on long-term glass performance. In this report, the authors show that DWPF glass, produced in compliance with this specification, can be expected to effectively limit the release of soluble radionuclides to natural environments. However, the release of insoluble radionuclides to the environment will be limited by their solubility, and not glass durability

  2. Doubling immunochemistry laboratory testing efficiency with the cobas e 801 module while maintaining consistency in analytical performance.

    Science.gov (United States)

    Findeisen, P; Zahn, I; Fiedler, G M; Leichtle, A B; Wang, S; Soria, G; Johnson, P; Henzell, J; Hegel, J K; Bendavid, C; Collet, N; McGovern, M; Klopprogge, K

    2018-06-04

    The new immunochemistry cobas e 801 module (Roche Diagnostics) was developed to meet increasing demands on routine laboratories to further improve testing efficiency, while maintaining high quality and reliable data. During a non-interventional multicenter evaluation study, the overall performance, functionality and reliability of the new module was investigated under routine-like conditions. It was tested as a dedicated immunochemistry system at four sites and as a consolidator combined with clinical chemistry at three sites. We report on testing efficiency and analytical performance of the new module. Evaluation of sample workloads with site-specific routine request patterns demonstrated increased speed and almost doubled throughput (maximal 300 tests per h), thus revealing that one cobas e 801 module can replace two cobas e 602 modules while saving up to 44% floor space. Result stability was demonstrated by QC analysis per assay throughout the study. Precision testing over 21 days yielded excellent results within and between labs, and, method comparison performed versus the cobas e 602 module routine results showed high consistency of results for all assays under study. In a practicability assessment related to performance and handling, 99% of graded features met (44%) or even exceeded (55%) laboratory expectations, with enhanced reagent management and loading during operation being highlighted. By nearly doubling immunochemistry testing efficiency on the same footprint as a cobas e 602 module, the new module has a great potential to further consolidate and enhance laboratory testing while maintaining high quality analytical performance with Roche platforms. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Modeling and Testing Legacy Data Consistency Requirements

    DEFF Research Database (Denmark)

    Nytun, J. P.; Jensen, Christian Søndergaard

    2003-01-01

    An increasing number of data sources are available on the Internet, many of which offer semantically overlapping data, but based on different schemas, or models. While it is often of interest to integrate such data sources, the lack of consistency among them makes this integration difficult....... This paper addresses the need for new techniques that enable the modeling and consistency checking for legacy data sources. Specifically, the paper contributes to the development of a framework that enables consistency testing of data coming from different types of data sources. The vehicle is UML and its...... accompanying XMI. The paper presents techniques for modeling consistency requirements using OCL and other UML modeling elements: it studies how models that describe the required consistencies among instances of legacy models can be designed in standard UML tools that support XMI. The paper also considers...

  4. Student Effort, Consistency and Online Performance

    Directory of Open Access Journals (Sweden)

    Hilde Patron

    2011-07-01

    Full Text Available This paper examines how student effort, consistency, motivation, and marginal learning, influence student grades in an online course. We use data from eleven Microeconomics courses taught online for a total of 212 students. Our findings show that consistency, or less time variation, is a statistically significant explanatory variable, whereas effort, or total minutes spent online, is not. Other independent variables include GPA and the difference between a pre-test and a post-test. The GPA is used as a measure of motivation, and the difference between a post-test and pre-test as marginal learning. As expected, the level of motivation is found statistically significant at a 99% confidence level, and marginal learning is also significant at a 95% level.

  5. Do Health Systems Have Consistent Performance Across Locations and Is Consistency Associated With Higher Performance?

    Science.gov (United States)

    Crespin, Daniel J; Christianson, Jon B; McCullough, Jeffrey S; Finch, Michael D

    This study addresses whether health systems have consistent diabetes care performance across their ambulatory clinics and whether increasing consistency is associated with improvements in clinic performance. Study data included 2007 to 2013 diabetes care intermediate outcome measures for 661 ambulatory clinics in Minnesota and bordering states. Health systems provided more consistent performance, as measured by the standard deviation of performance for clinics in a system, relative to propensity score-matched proxy systems created for comparison purposes. No evidence was found that improvements in consistency were associated with higher clinic performance. The combination of high performance and consistent care is likely to enhance a health system's brand reputation, allowing it to better mitigate the financial risks of consumers seeking care outside the organization. These results suggest that larger health systems are most likely to deliver the combination of consistent and high-performance care. Future research should explore the mechanisms that drive consistent care within health systems.

  6. Testing the visual consistency of web sites

    NARCIS (Netherlands)

    van der Geest, Thea; Loorbach, N.R.

    2005-01-01

    Consistency in the visual appearance of Web pages is often checked by experts, such as designers or reviewers. This article reports a card sort study conducted to determine whether users rather than experts could distinguish visual (in-)consistency in Web elements and pages. The users proved to

  7. Student Effort, Consistency, and Online Performance

    Science.gov (United States)

    Patron, Hilde; Lopez, Salvador

    2011-01-01

    This paper examines how student effort, consistency, motivation, and marginal learning, influence student grades in an online course. We use data from eleven Microeconomics courses taught online for a total of 212 students. Our findings show that consistency, or less time variation, is a statistically significant explanatory variable, whereas…

  8. An Improved Cognitive Model of the Iowa and Soochow Gambling Tasks With Regard to Model Fitting Performance and Tests of Parameter Consistency

    Directory of Open Access Journals (Sweden)

    Junyi eDai

    2015-03-01

    Full Text Available The Iowa Gambling Task (IGT and the Soochow Gambling Task (SGT are two experience-based risky decision-making tasks for examining decision-making deficits in clinical populations. Several cognitive models, including the expectancy-valence learning model (EVL and the prospect valence learning model (PVL, have been developed to disentangle the motivational, cognitive, and response processes underlying the explicit choices in these tasks. The purpose of the current study was to develop an improved model that can fit empirical data better than the EVL and PVL models and, in addition, produce more consistent parameter estimates across the IGT and SGT. Twenty-six opiate users (mean age 34.23; SD 8.79 and 27 control participants (mean age 35; SD 10.44 completed both tasks. Eighteen cognitive models varying in evaluation, updating, and choice rules were fit to individual data and their performances were compared to that of a statistical baseline model to find a best fitting model. The results showed that the model combining the prospect utility function treating gains and losses separately, the decay-reinforcement updating rule, and the trial-independent choice rule performed the best in both tasks. Furthermore, the winning model produced more consistent individual parameter estimates across the two tasks than any of the other models.

  9. Consistency test of the standard model

    International Nuclear Information System (INIS)

    Pawlowski, M.; Raczka, R.

    1997-01-01

    If the 'Higgs mass' is not the physical mass of a real particle but rather an effective ultraviolet cutoff then a process energy dependence of this cutoff must be admitted. Precision data from at least two energy scale experimental points are necessary to test this hypothesis. The first set of precision data is provided by the Z-boson peak experiments. We argue that the second set can be given by 10-20 GeV e + e - colliders. We pay attention to the special role of tau polarization experiments that can be sensitive to the 'Higgs mass' for a sample of ∼ 10 8 produced tau pairs. We argue that such a study may be regarded as a negative selfconsistency test of the Standard Model and of most of its extensions

  10. Potential application of the consistency approach for vaccine potency testing.

    Science.gov (United States)

    Arciniega, J; Sirota, L A

    2012-01-01

    The Consistency Approach offers the possibility of reducing the number of animals used for a potency test. However, it is critical to assess the effect that such reduction may have on assay performance. Consistency of production, sometimes referred to as consistency of manufacture or manufacturing, is an old concept implicit in regulation, which aims to ensure the uninterrupted release of safe and effective products. Consistency of manufacture can be described in terms of process capability, or the ability of a process to produce output within specification limits. For example, the standard method for potency testing of inactivated rabies vaccines is a multiple-dilution vaccination challenge test in mice that gives a quantitative, although highly variable estimate. On the other hand, a single-dilution test that does not give a quantitative estimate, but rather shows if the vaccine meets the specification has been proposed. This simplified test can lead to a considerable reduction in the number of animals used. However, traditional indices of process capability assume that the output population (potency values) is normally distributed, which clearly is not the case for the simplified approach. Appropriate computation of capability indices for the latter case will require special statistical considerations.

  11. Migraine patients consistently show abnormal vestibular bedside tests

    Directory of Open Access Journals (Sweden)

    Eliana Teixeira Maranhão

    2015-01-01

    Full Text Available Migraine and vertigo are common disorders, with lifetime prevalences of 16% and 7% respectively, and co-morbidity around 3.2%. Vestibular syndromes and dizziness occur more frequently in migraine patients. We investigated bedside clinical signs indicative of vestibular dysfunction in migraineurs.Objective To test the hypothesis that vestibulo-ocular reflex, vestibulo-spinal reflex and fall risk (FR responses as measured by 14 bedside tests are abnormal in migraineurs without vertigo, as compared with controls.Method Cross-sectional study including sixty individuals – thirty migraineurs, 25 women, 19-60 y-o; and 30 gender/age healthy paired controls.Results Migraineurs showed a tendency to perform worse in almost all tests, albeit only the Romberg tandem test was statistically different from controls. A combination of four abnormal tests better discriminated the two groups (93.3% specificity.Conclusion Migraine patients consistently showed abnormal vestibular bedside tests when compared with controls.

  12. Migraine patients consistently show abnormal vestibular bedside tests.

    Science.gov (United States)

    Maranhão, Eliana Teixeira; Maranhão-Filho, Péricles; Luiz, Ronir Raggio; Vincent, Maurice Borges

    2016-01-01

    Migraine and vertigo are common disorders, with lifetime prevalences of 16% and 7% respectively, and co-morbidity around 3.2%. Vestibular syndromes and dizziness occur more frequently in migraine patients. We investigated bedside clinical signs indicative of vestibular dysfunction in migraineurs. To test the hypothesis that vestibulo-ocular reflex, vestibulo-spinal reflex and fall risk (FR) responses as measured by 14 bedside tests are abnormal in migraineurs without vertigo, as compared with controls. Cross-sectional study including sixty individuals - thirty migraineurs, 25 women, 19-60 y-o; and 30 gender/age healthy paired controls. Migraineurs showed a tendency to perform worse in almost all tests, albeit only the Romberg tandem test was statistically different from controls. A combination of four abnormal tests better discriminated the two groups (93.3% specificity). Migraine patients consistently showed abnormal vestibular bedside tests when compared with controls.

  13. High-performance speech recognition using consistency modeling

    Science.gov (United States)

    Digalakis, Vassilios; Murveit, Hy; Monaco, Peter; Neumeyer, Leo; Sankar, Ananth

    1994-12-01

    The goal of SRI's consistency modeling project is to improve the raw acoustic modeling component of SRI's DECIPHER speech recognition system and develop consistency modeling technology. Consistency modeling aims to reduce the number of improper independence assumptions used in traditional speech recognition algorithms so that the resulting speech recognition hypotheses are more self-consistent and, therefore, more accurate. At the initial stages of this effort, SRI focused on developing the appropriate base technologies for consistency modeling. We first developed the Progressive Search technology that allowed us to perform large-vocabulary continuous speech recognition (LVCSR) experiments. Since its conception and development at SRI, this technique has been adopted by most laboratories, including other ARPA contracting sites, doing research on LVSR. Another goal of the consistency modeling project is to attack difficult modeling problems, when there is a mismatch between the training and testing phases. Such mismatches may include outlier speakers, different microphones and additive noise. We were able to either develop new, or transfer and evaluate existing, technologies that adapted our baseline genonic HMM recognizer to such difficult conditions.

  14. Consistency in performance evaluation reports and medical records.

    Science.gov (United States)

    Lu, Mingshan; Ma, Ching-to Albert

    2002-12-01

    In the health care market managed care has become the latest innovation for the delivery of services. For efficient implementation, the managed care organization relies on accurate information. So clinicians are often asked to report on patients before referrals are approved, treatments authorized, or insurance claims processed. What are clinicians responses to solicitation for information by managed care organizations? The existing health literature has already pointed out the importance of provider gaming, sincere reporting, nudging, and dodging the rules. We assess the consistency of clinicians reports on clients across administrative data and clinical records. For about 1,000 alcohol abuse treatment episodes, we compare clinicians reports across two data sets. The first one, the Maine Addiction Treatment System (MATS), was an administrative data set; the state government used it for program performance monitoring and evaluation. The second was a set of medical record abstracts, taken directly from the clinical records of treatment episodes. A clinician s reporting practice exhibits an inconsistency if the information reported in MATS differs from the information reported in the medical record in a statistically significant way. We look for evidence of inconsistencies in five categories: admission alcohol use frequency, discharge alcohol use frequency, termination status, admission employment status, and discharge employment status. Chi-square tests, Kappa statistics, and sensitivity and specificity tests are used for hypothesis testing. Multiple imputation methods are employed to address the problem of missing values in the record abstract data set. For admission and discharge alcohol use frequency measures, we find, respectively, strong and supporting evidence for inconsistencies. We find equally strong evidence for consistency in reports of admission and discharge employment status, and mixed evidence on report consistency on termination status. Patterns of

  15. Performance and consistency of indicator groups in two biodiversity hotspots.

    Directory of Open Access Journals (Sweden)

    Joaquim Trindade-Filho

    Full Text Available In a world limited by data availability and limited funds for conservation, scientists and practitioners must use indicator groups to define spatial conservation priorities. Several studies have evaluated the effectiveness of indicator groups, but still little is known about the consistency in performance of these groups in different regions, which would allow their a priori selection.We systematically examined the effectiveness and the consistency of nine indicator groups in representing mammal species in two top-ranked Biodiversity Hotspots (BH: the Brazilian Cerrado and the Atlantic Forest. To test for group effectiveness we first found the best sets of sites able to maximize the representation of each indicator group in the BH and then calculated the average representation of different target species by the indicator groups in the BH. We considered consistent indicator groups whose representation of target species was not statistically different between BH. We called effective those groups that outperformed the target-species representation achieved by random sets of species. Effective indicator groups required the selection of less than 2% of the BH area for representing target species. Restricted-range species were the most effective indicators for the representation of all mammal diversity as well as target species. It was also the only group with high consistency.We show that several indicator groups could be applied as shortcuts for representing mammal species in the Cerrado and the Atlantic Forest to develop conservation plans, however, only restricted-range species consistently held as the most effective indicator group for such a task. This group is of particular importance in conservation planning as it captures high diversity of endemic and endangered species.

  16. Performance and consistency of indicator groups in two biodiversity hotspots.

    Science.gov (United States)

    Trindade-Filho, Joaquim; Loyola, Rafael Dias

    2011-01-01

    In a world limited by data availability and limited funds for conservation, scientists and practitioners must use indicator groups to define spatial conservation priorities. Several studies have evaluated the effectiveness of indicator groups, but still little is known about the consistency in performance of these groups in different regions, which would allow their a priori selection. We systematically examined the effectiveness and the consistency of nine indicator groups in representing mammal species in two top-ranked Biodiversity Hotspots (BH): the Brazilian Cerrado and the Atlantic Forest. To test for group effectiveness we first found the best sets of sites able to maximize the representation of each indicator group in the BH and then calculated the average representation of different target species by the indicator groups in the BH. We considered consistent indicator groups whose representation of target species was not statistically different between BH. We called effective those groups that outperformed the target-species representation achieved by random sets of species. Effective indicator groups required the selection of less than 2% of the BH area for representing target species. Restricted-range species were the most effective indicators for the representation of all mammal diversity as well as target species. It was also the only group with high consistency. We show that several indicator groups could be applied as shortcuts for representing mammal species in the Cerrado and the Atlantic Forest to develop conservation plans, however, only restricted-range species consistently held as the most effective indicator group for such a task. This group is of particular importance in conservation planning as it captures high diversity of endemic and endangered species.

  17. Cosmological consistency tests of gravity theory and cosmic acceleration

    Science.gov (United States)

    Ishak-Boushaki, Mustapha B.

    2017-01-01

    Testing general relativity at cosmological scales and probing the cause of cosmic acceleration are among the important objectives targeted by incoming and future astronomical surveys and experiments. I present our recent results on consistency tests that can provide insights about the underlying gravity theory and cosmic acceleration using cosmological data sets. We use statistical measures, the rate of cosmic expansion, the growth rate of large scale structure, and the physical consistency of these probes with one another.

  18. Textiles Performance Testing Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Textiles Performance Testing Facilities has the capabilities to perform all physical wet and dry performance testing, and visual and instrumental color analysis...

  19. Short-Cut Estimators of Criterion-Referenced Test Consistency.

    Science.gov (United States)

    Brown, James Dean

    1990-01-01

    Presents simplified methods for deriving estimates of the consistency of criterion-referenced, English-as-a-Second-Language tests, including (1) the threshold loss agreement approach using agreement or kappa coefficients, (2) the squared-error loss agreement approach using the phi(lambda) dependability approach, and (3) the domain score…

  20. Short-term consistency testing vs. long-term behavior

    International Nuclear Information System (INIS)

    Ebert, W.L.; Bakel, A.J.; Wolf, S.F.; Strachan, D.M.

    1997-01-01

    The authors conducted Product Consistency Tests (PCTs) with a surrogate low-activity waste (LAW) glass to (1) evaluate the possible use of various test conditions in a specification test for LAW waste forms, (2) measure the reproducibility of the test at low temperatures, and (3) determine if the rates calculated from 7-day PCTs bound the rates measured in PCT conducted for longer durations, which represent more advanced corrosion. The effects of temperature and pH on the dissolution rate in PCTs are much less than the effects observed in dilute solutions due to the buildup of dissolved glass components in the PCTs. The precision of replicate 7-day tests at 20 and 40 degrees C was limited by the analytical uncertainty. The dissolution rates at all temperatures decreased with the test duration initially. However, the dissolution rates in tests at 70 and 90 degrees C increased when certain alteration phases formed after about 100 and 500 days, respectively; the rates in some tests exceeded that measured in a 7-day PCT. While the 7-day PCT does not provide a bounding rate for this glass at 70 or 90 degrees C, tests for longer durations are needed to determine if a 7-day test provides a bounding rate at lower temperatures

  1. Self-assessment: Strategy for higher standards, consistency, and performance

    International Nuclear Information System (INIS)

    Ide, W.E.

    1996-01-01

    In late 1994, Palo Verde operations underwent a transformation from a unitized structure to a single functional unit. It was necessary to build consistency in watchstanding practices and create a shared mission. Because there was a lack of focus on actual plant operations and because personnel were deeply involved with administrative tasks, command and control of evolutions were weak. Improvement was needed. Consistent performance standards have been set for all three operating units. These expectation focus on nuclear, radiological, and industrial safety. Straightforward descriptions of watchstanding and monitoring practices have been provided to all department personnel. The desired professional and leadership qualities for employee conduct have been defined and communicated thoroughly. A healthy and competitive atmosphere developed with the successful implementation of these standards. Overall performance improved. The auxiliary operators demonstrated increased pride and ownership in the performance of their work activities. In addition, their morale improved. Crew teamwork improved as well as the quality of shift briefs. There was a decrease in the noise level and the administrative functions in the control room. The use of self-assessment helped to anchor and define higher and more consistent standards. The proof of Palo Verde's success was evident when an Institute of Nuclear Power Operations finding was turned into a strength within 1 yr

  2. The Consistency of Performance Management System Based on Attributes of the Performance Indicator: An Empirical Study

    Directory of Open Access Journals (Sweden)

    Jan Zavadsky

    2014-07-01

    Full Text Available Purpose: The performance management system (PMS is a metasystem over all business processes at the strategic and operational level. Effectiveness of the various management systems depends on many factors. One of them is the consistent definition of each system elements. The main purpose of this study is to explore if the performance management systems of the sample companies is consistent and how companies can create such a system. The consistency in this case is based on the homogenous definition of attributes relating to the performance indicator as a basic element of PMS.Methodology: At the beginning, we used an affinity diagram that helped us to clarify and to group various attributes of performance indicators. The main research results we achieved are through empirical study. The empirical study was carried out in a sample of Slovak companies. The criterion for selection was the existence of the certified management systems according to the ISO 9001. Representativeness of the sample companies was confirmed by application of Pearson´s chi-squared test (χ2 - test due to above standards. Findings: Coming from the review of various literature, we defined four groups of attributes relating to the performance indicator: formal attributes, attributes of target value, informational attributes and attributes of evaluation. The whole set contains 21 attributes. The consistency of PMS is based not on maximum or minimum number of attributes, but on the same type of attributes for each performance indicator used in PMS at both the operational and strategic level. The main findings are: companies use various financial and non-financial indicators at strategic or operational level; companies determine various attributes of performance indicator, but most of the performance indicators are otherwise determined; we identified the common attributes for the whole sample of companies. Practical implications: The research results have got an implication for

  3. Inspection system performance test procedure

    International Nuclear Information System (INIS)

    Jensen, C.E.

    1995-01-01

    This procedure establishes requirements to administer a performance demonstration test. The test is to demonstrate that the double-shell tank inspection system (DSTIS) supplied by the contractor performs in accordance with the WHC-S-4108, Double-Shell Tank Ultrasonic Inspection Performance Specification, Rev. 2-A, January, 1995. The inspection system is intended to provide ultrasonic (UT) and visual data to determine integrity of the Westinghouse Hanford Company (WHC) site underground waste tanks. The robotic inspection system consists of the following major sub-systems (modules) and components: Mobile control center; Deployment module; Cable management assembly; Robot mechanism; Ultrasonic testing system; Visual testing system; Pneumatic system; Electrical system; and Control system

  4. Measuring consistency of web page design and its effects on performance and satisfaction.

    Science.gov (United States)

    Ozok, A A; Salvendy, G

    2000-04-01

    This study examines the methods for measuring the consistency levels of web pages and the effect of consistency on the performance and satisfaction of the world-wide web (WWW) user. For clarification, a home page is referred to as a single page that is the default page of a web site on the WWW. A web page refers to a single screen that indicates a specific address on the WWW. This study has tested a series of web pages that were mostly hyperlinked. Therefore, the term 'web page' has been adopted for the nomenclature while referring to the objects of which the features were tested. It was hypothesized that participants would perform better and be more satisfied using web pages that have consistent rather than inconsistent interface design; that the overall consistency level of an interface design would significantly correlate with the three elements of consistency, physical, communicational and conceptual consistency; and that physical and communicational consistencies would interact with each other. The hypotheses were tested in a four-group, between-subject design, with 10 participants in each group. The results partially support the hypothesis regarding error rate, but not regarding satisfaction and performance time. The results also support the hypothesis that each of the three elements of consistency significantly contribute to the overall consistency of a web page, and that physical and communicational consistencies interact with each other, while conceptual consistency does not interact with them.

  5. Test planning and performance

    International Nuclear Information System (INIS)

    Zola, Maurizio

    2001-01-01

    Testing plan should include Safety guide Q4 - Inspection and testing - A testing plan should be prepared including following information: General information (facility name, item or system reference, procurement document reference, document reference number and status, associated procedures and drawings); A sequential listing of all testing activities; Procedure, work instruction, specification or standard to be followed in respect of each operation and test; Acceptance criteria; Identification of who is performing tests; Identification of hold points; Type of records to be prepared for each test; Persons and organizations having authority for final acceptance. Proposed activities sequence is: visual, electrical and mechanical checks; environmental tests (thermal aging, vibrations aging, radioactive aging); performance evaluation in extreme conditions; dynamic tests with functional checks; final electrical and mechanical checks The planning of the tests should always be performed taking into account an interpretative model: a very tight cooperation is advisable between experimental people and numerical people dealing with the analysis of more or less complex models for the seismic assessment of structures and components. Preparatory phase should include the choice of the following items should be agreed upon with the final user of the tests: Excitation points, Excitation types, Excitation amplitude with respect to frequency, Measuring points. Data acquisition, recording and storage, should take into account the characteristics of the successive data processing: to much data can be cumbersome to be processed, but to few data can make unusable the experimental results. The parameters for time history acquisition should be chosen taking into account data processing: for Shock Response Spectrum calculation some special requirements should be met: frequency bounded signal, high frequency sampling, shock noise. For stationary random-like excitation, the sample length

  6. A Bayesian Decision-Theoretic Approach to Logically-Consistent Hypothesis Testing

    Directory of Open Access Journals (Sweden)

    Gustavo Miranda da Silva

    2015-09-01

    Full Text Available This work addresses an important issue regarding the performance of simultaneous test procedures: the construction of multiple tests that at the same time are optimal from a statistical perspective and that also yield logically-consistent results that are easy to communicate to practitioners of statistical methods. For instance, if hypothesis A implies hypothesis B, is it possible to create optimal testing procedures that reject A whenever they reject B? Unfortunately, several standard testing procedures fail in having such logical consistency. Although this has been deeply investigated under a frequentist perspective, the literature lacks analyses under a Bayesian paradigm. In this work, we contribute to the discussion by investigating three rational relationships under a Bayesian decision-theoretic standpoint: coherence, invertibility and union consonance. We characterize and illustrate through simple examples optimal Bayes tests that fulfill each of these requisites separately. We also explore how far one can go by putting these requirements together. We show that although fairly intuitive tests satisfy both coherence and invertibility, no Bayesian testing scheme meets the desiderata as a whole, strengthening the understanding that logical consistency cannot be combined with statistical optimality in general. Finally, we associate Bayesian hypothesis testing with Bayes point estimation procedures. We prove the performance of logically-consistent hypothesis testing by means of a Bayes point estimator to be optimal only under very restrictive conditions.

  7. Consistency across repeated eyewitness interviews: contrasting police detectives' beliefs with actual eyewitness performance.

    Science.gov (United States)

    Krix, Alana C; Sauerland, Melanie; Lorei, Clemens; Rispens, Imke

    2015-01-01

    In the legal system, inconsistencies in eyewitness accounts are often used to discredit witnesses' credibility. This is at odds with research findings showing that witnesses frequently report reminiscent details (details previously unrecalled) at an accuracy rate that is nearly as high as for consistently recalled information. The present study sought to put the validity of beliefs about recall consistency to a test by directly comparing them with actual memory performance in two recall attempts. All participants watched a film of a staged theft. Subsequently, the memory group (N = 84) provided one statement immediately after the film (either with the Self-Administered Interview or free recall) and one after a one-week delay. The estimation group (N = 81) consisting of experienced police detectives estimated the recall performance of the memory group. The results showed that actual recall performance was consistently underestimated. Also, a sharp decline of memory performance between recall attempts was assumed by the estimation group whereas actual accuracy remained stable. While reminiscent details were almost as accurate as consistent details, they were estimated to be much less accurate than consistent information and as inaccurate as direct contradictions. The police detectives expressed a great concern that reminiscence was the result of suggestive external influences. In conclusion, it seems that experienced police detectives hold many implicit beliefs about recall consistency that do not correspond with actual recall performance. Recommendations for police trainings are provided. These aim at fostering a differentiated view on eyewitness performance and the inclusion of more comprehensive classes on human memory structure.

  8. System Performance and Testing

    NARCIS (Netherlands)

    Frei, U.; Oversloot, H.

    2004-01-01

    This chapter compares and contrasts the system performance of two widely used solar thermal systems using testing and simulation programs. Solar thermal systems are used in many countries for heating domestically used water. In addition to the simple thermosiphon systems, better designed pumped

  9. Dark energy two decades after: observables, probes, consistency tests.

    Science.gov (United States)

    Huterer, Dragan; Shafer, Daniel L

    2018-01-01

    The discovery of the accelerating universe in the late 1990s was a watershed moment in modern cosmology, as it indicated the presence of a fundamentally new, dominant contribution to the energy budget of the universe. Evidence for dark energy, the new component that causes the acceleration, has since become extremely strong, owing to an impressive variety of increasingly precise measurements of the expansion history and the growth of structure in the universe. Still, one of the central challenges of modern cosmology is to shed light on the physical mechanism behind the accelerating universe. In this review, we briefly summarize the developments that led to the discovery of dark energy. Next, we discuss the parametric descriptions of dark energy and the cosmological tests that allow us to better understand its nature. We then review the cosmological probes of dark energy. For each probe, we briefly discuss the physics behind it and its prospects for measuring dark energy properties. We end with a summary of the current status of dark energy research.

  10. The performance testing

    International Nuclear Information System (INIS)

    Mayr, A.

    1975-01-01

    Concerning the time-schedule of reactor performance tests they normally begin when suppliers or constructors have finished construction and made all necessary construction and coordinated tests. If the last-mentioned tests are conducted profoundly, they contribute substantially to a quick and simple carrying-out of the last performance tests and to the general quality of components and systems. At this stage all components of a system should be properly fixed, machinery, instruments and electrical components adjusted and calibrated, all set-points tested, electrical and other supply units in operation or ready to operate and all functions pretested. Just at this stage of the work most of the existing defects and failures of systems can be found. Remembering the fact that the difficulty of operation of complex systems results from detail problems, it is extremely useful to remove all things of this kind as soon as possible, at the latest at this time where it is done easily and normally quickly without influencing start-up-procedures of other systems or even of the total plant. (orig./TK) [de

  11. Understanding protocol performance: impact of test performance.

    Science.gov (United States)

    Turner, Robert G

    2013-01-01

    This is the second of two articles that examine the factors that determine protocol performance. The objective of these articles is to provide a general understanding of protocol performance that can be used to estimate performance, establish limits on performance, decide if a protocol is justified, and ultimately select a protocol. The first article was concerned with protocol criterion and test correlation. It demonstrated the advantages and disadvantages of different criterion when all tests had the same performance. It also examined the impact of increasing test correlation on protocol performance and the characteristics of the different criteria. To examine the impact on protocol performance when individual tests in a protocol have different performance. This is evaluated for different criteria and test correlations. The results of the two articles are combined and summarized. A mathematical model is used to calculate protocol performance for different protocol criteria and test correlations when there are small to large variations in the performance of individual tests in the protocol. The performance of the individual tests that make up a protocol has a significant impact on the performance of the protocol. As expected, the better the performance of the individual tests, the better the performance of the protocol. Many of the characteristics of the different criteria are relatively independent of the variation in the performance of the individual tests. However, increasing test variation degrades some criteria advantages and causes a new disadvantage to appear. This negative impact increases as test variation increases and as more tests are added to the protocol. Best protocol performance is obtained when individual tests are uncorrelated and have the same performance. In general, the greater the variation in the performance of tests in the protocol, the more detrimental this variation is to protocol performance. Since this negative impact is increased as

  12. Consistency across Repeated Eyewitness Interviews: Contrasting Police Detectives’ Beliefs with Actual Eyewitness Performance

    Science.gov (United States)

    Krix, Alana C.; Sauerland, Melanie; Lorei, Clemens; Rispens, Imke

    2015-01-01

    In the legal system, inconsistencies in eyewitness accounts are often used to discredit witnesses’ credibility. This is at odds with research findings showing that witnesses frequently report reminiscent details (details previously unrecalled) at an accuracy rate that is nearly as high as for consistently recalled information. The present study sought to put the validity of beliefs about recall consistency to a test by directly comparing them with actual memory performance in two recall attempts. All participants watched a film of a staged theft. Subsequently, the memory group (N = 84) provided one statement immediately after the film (either with the Self-Administered Interview or free recall) and one after a one-week delay. The estimation group (N = 81) consisting of experienced police detectives estimated the recall performance of the memory group. The results showed that actual recall performance was consistently underestimated. Also, a sharp decline of memory performance between recall attempts was assumed by the estimation group whereas actual accuracy remained stable. While reminiscent details were almost as accurate as consistent details, they were estimated to be much less accurate than consistent information and as inaccurate as direct contradictions. The police detectives expressed a great concern that reminiscence was the result of suggestive external influences. In conclusion, it seems that experienced police detectives hold many implicit beliefs about recall consistency that do not correspond with actual recall performance. Recommendations for police trainings are provided. These aim at fostering a differentiated view on eyewitness performance and the inclusion of more comprehensive classes on human memory structure. PMID:25695428

  13. Consistency across repeated eyewitness interviews: contrasting police detectives' beliefs with actual eyewitness performance.

    Directory of Open Access Journals (Sweden)

    Alana C Krix

    Full Text Available In the legal system, inconsistencies in eyewitness accounts are often used to discredit witnesses' credibility. This is at odds with research findings showing that witnesses frequently report reminiscent details (details previously unrecalled at an accuracy rate that is nearly as high as for consistently recalled information. The present study sought to put the validity of beliefs about recall consistency to a test by directly comparing them with actual memory performance in two recall attempts. All participants watched a film of a staged theft. Subsequently, the memory group (N = 84 provided one statement immediately after the film (either with the Self-Administered Interview or free recall and one after a one-week delay. The estimation group (N = 81 consisting of experienced police detectives estimated the recall performance of the memory group. The results showed that actual recall performance was consistently underestimated. Also, a sharp decline of memory performance between recall attempts was assumed by the estimation group whereas actual accuracy remained stable. While reminiscent details were almost as accurate as consistent details, they were estimated to be much less accurate than consistent information and as inaccurate as direct contradictions. The police detectives expressed a great concern that reminiscence was the result of suggestive external influences. In conclusion, it seems that experienced police detectives hold many implicit beliefs about recall consistency that do not correspond with actual recall performance. Recommendations for police trainings are provided. These aim at fostering a differentiated view on eyewitness performance and the inclusion of more comprehensive classes on human memory structure.

  14. Product consistency leach tests of Savannah River Site radioactive waste glasses

    International Nuclear Information System (INIS)

    Bibler, N.E.; Bates, J.K.

    1989-01-01

    The Product Consistency Test (PCT) is a glass leach test that was developed at the Savannah River Site (SRS) to routinely confirm the durability of nuclear waste glasses that will be produced in the Defense Waste Processing Facility. The PCT is a 7 day, crushed glass leach test in deionized water at 90 degree C. Final leachates are filtered and acidified prior to analysis. To demonstrate the reproducibility of the PCT when performed remotely, SRS and Argonne National Laboratory have performed the PCT on samples of two radioactive glasses. The tests were also performed to compare the releases of the radionuclides with the major nonradioactive glass components and to determine if radiation from the glass was affecting the results of the PCT. The test was performed in triplicate at each laboratory. For the major soluble elements, B, Li, Na, and Si, in the glass, each investigator obtained relative precisions in the range 2--5% in the triplicate tests. This range indicates good precision for the PCT when performed remotely with master slave manipulators in a shielded cell environment

  15. Numerical investigation of degas performance on impeller of medium-consistency pump

    Directory of Open Access Journals (Sweden)

    Hong Li

    2015-12-01

    Full Text Available Medium-consistency technology is known as the process with high efficiency and low pollution. The gas distribution was simulated in the medium-consistency pump with different degas hole positions. Rheological behaviors of pulp suspension were obtained by experimental test. A modified Herschel–Bulkley model and the Eulerian gas–liquid two-phase flow model were utilized to approximately represent the behaviors of the medium-consistency pulp suspension. The results show that when the relative position is 0.53, the gas volume ratio is less than 0.1% at the pump outlet and 9.8% at the vacuum inlet, and the pump head is at the maximum. Because of the different numbers of the impeller blades and turbulence blades and the asymmetric volute structure, the gas is distributed unevenly in the impeller. In addition, the pump performance was tested in experiment and the results are used to validate computational fluid dynamics outcomes.

  16. Product consistency leach tests of Savannah River Site radioactive waste glasses

    International Nuclear Information System (INIS)

    Bibler, N.E.; Bates, J.K.

    1990-01-01

    The product consistency test (PCT) is a glass leach test developed at the Savannah River Site (SRS) to confirm the durability of radioactive nuclear waste glasses that will be produced in the Defense Waste Processing Facility. The PCT is a seven day, crushed glass leach test in deionized water at 90C. Final leachates are filtered and acidified prior to analysis. To demonstrate the reproducibility of the PCT when performed remotely, SRS and Argonne National Laboratory have performed the PCT on samples of two radioactive glasses. The tests were also performed to compare the releases of the radionuclides with the major nonradioactive glass components and to determine if radiation from the glass was affecting the results of the PCT. The test was performed in triplicate at each laboratory. For the major soluble elements, B, Li, Na, and Si, in the glass, each investigator obtained relative precisions in the range 2-5% in the triplicate tests. This range indicates good precision for the PCT when performed remotely with master slave manipulators in a shielded cell environment. When the results of the two laboratories were compared to each other, the agreement was within 20%. Normalized concentrations for the nonradioactive and radioactive elements in the PCT leachates measured at both facilities indicated that the radionuclides were released from the glass slower than the major soluble elements in the glass. For both laboratories, the normalized releases for both glasses were in the general order Li ∼ B ∼ Na > Si > Cs - 137 > Sb - 125 < Sr - 90. The normalized releases for the major soluble elements and the final pH values in the tests with radioactive glass are consistent with those for nonradioactive glasses with similar compositions. This indicates that there was no significant effect of radiation on the results of the PCT

  17. Outcomes Definitions and Statistical Tests in Oncology Studies: A Systematic Review of the Reporting Consistency.

    Science.gov (United States)

    Rivoirard, Romain; Duplay, Vianney; Oriol, Mathieu; Tinquaut, Fabien; Chauvin, Franck; Magne, Nicolas; Bourmaud, Aurelie

    2016-01-01

    Quality of reporting for Randomized Clinical Trials (RCTs) in oncology was analyzed in several systematic reviews, but, in this setting, there is paucity of data for the outcomes definitions and consistency of reporting for statistical tests in RCTs and Observational Studies (OBS). The objective of this review was to describe those two reporting aspects, for OBS and RCTs in oncology. From a list of 19 medical journals, three were retained for analysis, after a random selection: British Medical Journal (BMJ), Annals of Oncology (AoO) and British Journal of Cancer (BJC). All original articles published between March 2009 and March 2014 were screened. Only studies whose main outcome was accompanied by a corresponding statistical test were included in the analysis. Studies based on censored data were excluded. Primary outcome was to assess quality of reporting for description of primary outcome measure in RCTs and of variables of interest in OBS. A logistic regression was performed to identify covariates of studies potentially associated with concordance of tests between Methods and Results parts. 826 studies were included in the review, and 698 were OBS. Variables were described in Methods section for all OBS studies and primary endpoint was clearly detailed in Methods section for 109 RCTs (85.2%). 295 OBS (42.2%) and 43 RCTs (33.6%) had perfect agreement for reported statistical test between Methods and Results parts. In multivariable analysis, variable "number of included patients in study" was associated with test consistency: aOR (adjusted Odds Ratio) for third group compared to first group was equal to: aOR Grp3 = 0.52 [0.31-0.89] (P value = 0.009). Variables in OBS and primary endpoint in RCTs are reported and described with a high frequency. However, statistical tests consistency between methods and Results sections of OBS is not always noted. Therefore, we encourage authors and peer reviewers to verify consistency of statistical tests in oncology studies.

  18. Test of Gross Motor Development : Expert Validity, confirmatory validity and internal consistence

    Directory of Open Access Journals (Sweden)

    Nadia Cristina Valentini

    2008-12-01

    Full Text Available The Test of Gross Motor Development (TGMD-2 is an instrument used to evaluate children’s level of motordevelopment. The objective of this study was to translate and verify the clarity and pertinence of the TGMD-2 items by expertsand the confirmatory factorial validity and the internal consistence by means of test-retest of the Portuguese TGMD-2. Across-cultural translation was used to construct the Portuguese version. The participants of this study were 7 professionalsand 587 children, from 27 schools (kindergarten and elementary from 3 to 10 years old (51.1% boys and 48.9% girls.Each child was videotaped performing the test twice. The videotaped tests were then scored. The results indicated thatthe Portuguese version of the TGMD-2 contains clear and pertinent motor items; demonstrated satisfactory indices ofconfirmatory factorial validity (χ2/gl = 3.38; Goodness-of-fit Index = 0.95; Adjusted Goodness-of-fit index = 0.92 and Tuckerand Lewis’s Index of Fit = 0.83 and test-retest internal consistency (locomotion r = 0.82; control of object: r = 0.88. ThePortuguese TGMD-2 demonstrated validity and reliability for the sample investigated.

  19. Test of Gross Motor Development: expert validity, confirmatory validity and internal consistence

    Directory of Open Access Journals (Sweden)

    Nadia Cristina Valentini

    2008-01-01

    The Test of Gross Motor Development (TGMD-2 is an instrument used to evaluate children’s level of motor development. The objective of this study was to translate and verify the clarity and pertinence of the TGMD-2 items by experts and the confirmatory factorial validity and the internal consistence by means of test-retest of the Portuguese TGMD-2. A cross-cultural translation was used to construct the Portuguese version. The participants of this study were 7 professionals and 587 children, from 27 schools (kindergarten and elementary from 3 to 10 years old (51.1% boys and 48.9% girls. Each child was videotaped performing the test twice. The videotaped tests were then scored. The results indicated that the Portuguese version of the TGMD-2 contains clear and pertinent motor items; demonstrated satisfactory indices of confirmatory factorial validity (÷2/gl = 3.38; Goodness-of-fit Index = 0.95; Adjusted Goodness-of-fit index = 0.92 and Tucker and Lewis’s Index of Fit = 0.83 and test-retest internal consistency (locomotion r = 0.82; control of object: r = 0.88. The Portuguese TGMD-2 demonstrated validity and reliability for the sample investigated.

  20. Force Concept Inventory-based multiple-choice test for investigating students’ representational consistency

    Directory of Open Access Journals (Sweden)

    Pasi Nieminen

    2010-08-01

    Full Text Available This study investigates students’ ability to interpret multiple representations consistently (i.e., representational consistency in the context of the force concept. For this purpose we developed the Representational Variant of the Force Concept Inventory (R-FCI, which makes use of nine items from the 1995 version of the Force Concept Inventory (FCI. These original FCI items were redesigned using various representations (such as motion map, vectorial and graphical, yielding 27 multiple-choice items concerning four central concepts underpinning the force concept: Newton’s first, second, and third laws, and gravitation. We provide some evidence for the validity and reliability of the R-FCI; this analysis is limited to the student population of one Finnish high school. The students took the R-FCI at the beginning and at the end of their first high school physics course. We found that students’ (n=168 representational consistency (whether scientifically correct or not varied considerably depending on the concept. On average, representational consistency and scientifically correct understanding increased during the instruction, although in the post-test only a few students performed consistently both in terms of representations and scientifically correct understanding. We also compared students’ (n=87 results of the R-FCI and the FCI, and found that they correlated quite well.

  1. Nuclear waste glass product consistency test (PCT), Version 5.0

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.; Waters, B.J.

    1992-06-01

    Liquid high-level nuclear waste will be immobilized at the Savannah River Site (SRS) by vitrification in borosilicate glass. The glass will be produced in the Defense Waste Processing Facility (DWPF), poured into stainless steel canisters, and eventually disposed of in a geologic repository. In order to comply with the Waste Acceptance Preliminary Specifications (WAPS), the durability of the glass needs to be measured during production to assure its long term stability and radionuclide release properties. A durability test, designated the Produce Consistency Test (PCT), was developed for DWPF glass in order to meet the WAPS requirements. The response of the PCT procedure was based on extensive testing with glasses of widely different compositions. The PCT was determined to be very reproducible, to yield reliable results rapidly, and to be easily performed in shielded cell facilities with radioactive samples. Version 5.0 of the PCT procedure is attached

  2. Development of an ASTM standard glass durability test, the Product Consistency Test (PCT), for high level radioactive waste glass

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.

    1994-01-01

    The nation's first, and the world's largest, facility to immobilize high-level nuclear waste in durable borosilicate glass has started operation at the Savannah River Site (SRS) in Aiken, South Carolina. The product specifications on the glass wasteform produced in the Defense Waste Processing Facility (DWPF) required extensive characterization of the glass product before actual production began and for continued characterization during production. To aid in this characterization, a glass durability (leach) test was needed that was easily reproducible, could be performed remotely on highly radioactive samples, and could yield results rapidly. Several standard leach tests were examined with a variety of test configurations. Using existing tests as a starting point, the DWPF Product Consistency Test (PCT was developed in which crushed glass samples are exposed to 90 ± 2 degree C deionized water for seven days. Based on extensive testing, including a seven-laboratory round robin and confirmatory testing with radioactive samples, the PCT is very reproducible, yields reliable results rapidly, and can be performed in shielded cell facilities with radioactive samples

  3. GLASS FABRICATION AND PRODUCT CONSISTENCY TESTING OF LANTHANIDE BOROSILICATE FRIT X COMPOSITION FOR PLUTONIUM DISPOSITION

    Energy Technology Data Exchange (ETDEWEB)

    Marra, J

    2006-11-15

    The Department of Energy Office of Environmental Management (DOE/EM) plans to conduct the Plutonium Disposition Project at the Savannah River Site (SRS) to disposition excess weapons-usable plutonium. A plutonium glass waste form is the preferred option for immobilization of the plutonium for subsequent disposition in a geologic repository. A reference glass composition (Lanthanide Borosilicate (LaBS) Frit B) was developed during the Plutonium Immobilization Program (PIP) to immobilize plutonium in the late 1990's. A limited amount of performance testing was performed on this baseline composition before efforts to further pursue Pu disposition via a glass waste form ceased. Recent FY05 studies have further investigated the LaBS Frit B formulation as well as development of a newer LaBS formulation denoted as LaBS Frit X. The objectives of this present task were to fabricate plutonium loaded LaBS Frit X glass and perform corrosion testing to provide near-term data that will increase confidence that LaBS glass product is suitable for disposal in the Yucca Mountain Repository. Specifically, testing was conducted in an effort to provide data to Yucca Mountain Project (YMP) personnel for use in performance assessment calculations. Plutonium containing LaBS glass with the Frit X composition with a 9.5 wt% PuO{sub 2} loading was prepared for testing. Glass was prepared to support Product Consistency Testing (PCT) at Savannah River National Laboratory (SRNL). The glass was thoroughly characterized using x-ray diffraction (XRD) and scanning electron microscopy coupled with energy dispersive spectroscopy (SEM/EDS) prior to performance testing. A series of PCTs were conducted at SRNL using quenched Pu Frit X glass with varying exposed surface areas. Effects of isothermal and can-in-canister heat treatments on the Pu Frit X glass were also investigated. Another series of PCTs were performed on these different heat-treated Pu Frit X glasses. Leachates from all these PCTs

  4. Evaluation of the entropy consistent euler flux on 1D and 2D test problems

    Science.gov (United States)

    Roslan, Nur Khairunnisa Hanisah; Ismail, Farzad

    2012-06-01

    Perhaps most CFD simulations may yield good predictions of pressure and velocity when compared to experimental data. Unfortunately, these results will most likely not adhere to the second law of thermodynamics hence comprising the authenticity of predicted data. Currently, the test of a good CFD code is to check how much entropy is generated in a smooth flow and hope that the numerical entropy produced is of the correct sign when a shock is encountered. Herein, a shock capturing code written in C++ based on a recent entropy consistent Euler flux is developed to simulate 1D and 2D flows. Unlike other finite volume schemes in commercial CFD code, this entropy consistent flux (EC) function precisely satisfies the discrete second law of thermodynamics. This EC flux has an entropy-conserved part, preserving entropy for smooth flows and a numerical diffusion part that will accurately produce the proper amount of entropy, consistent with the second law. Several numerical simulations of the entropy consistent flux have been tested on two dimensional test cases. The first case is a Mach 3 flow over a forward facing step. The second case is a flow over a NACA 0012 airfoil while the third case is a hypersonic flow passing over a 2D cylinder. Local flow quantities such as velocity and pressure are analyzed and then compared with mainly the Roe flux. The results herein show that the EC flux does not capture the unphysical rarefaction shock unlike the Roe-flux and does not easily succumb to the carbuncle phenomenon. In addition, the EC flux maintains good performance in cases where the Roe flux is known to be superior.

  5. A diagnostic test for apraxia in stroke patients: internal consistency and diagnostic value.

    NARCIS (Netherlands)

    Heugten, C.M. van; Dekker, J.; Deelman, B.G.; Stehmann-Saris, F.C.; Kinebanian, A.

    1999-01-01

    The internal consistency and the diagnostic value of a test for apraxia in patients having had a stroke are presented. Results indicate that the items of the test form a strong and consistent scale: Cronbach's alpha as well as the results of a Mokken scale analysis present good reliability and good

  6. General approach to the testing of binary solubility systems for thermodynamic consistency. Consolidated Fuel Reprocessing Program

    International Nuclear Information System (INIS)

    Hamm, L.L.; Van Brunt, V.

    1982-08-01

    A comparison of implicit Runge-Kutta and orthogonal collocation methods is made for the numerical solution to the ordinary differential equation which describes the high-pressure vapor-liquid equilibria of a binary system. The systems of interest are limited to binary solubility systems where one of the components is supercritical and exists as a noncondensable gas in the pure state. Of the two methods - implicit Runge-Kuta and orthogonal collocation - this paper attempts to present some preliminary but not necessarily conclusive results that the implicit Runge-Kutta method is superior for the solution to the ordinary differential equation utilized in the thermodynamic consistency testing of binary solubility systems. Due to the extreme nonlinearity of thermodynamic properties in the region near the critical locus, an extended cubic spline fitting technique is devised for correlating the P-x data. The least-squares criterion is employed in smoothing the experimental data. Even though the derivation is presented specifically for the correlation of P-x data, the technique could easily be applied to any thermodynamic data by changing the endpoint requirements. The volumetric behavior of the systems must be given or predicted in order to perform thermodynamic consistency tests. A general procedure is developed for predicting the volumetric behavior required and some indication as to the expected limit of accuracy is given

  7. Nuclear waste glass product consistency test (PCT): Version 7.0. Revision 3

    International Nuclear Information System (INIS)

    Jantzen, C.M.; Bibler, N.E.; Beam, D.C.; Ramsey, W.G.

    1994-06-01

    Liquid high-level nuclear waste will be immobilized at the Savannah River Site (SRS) by vitrification in borosilicate glass. The glass will be produced in the Defense Waste Processing Facility (DWPF), poured into stainless steel canisters, and eventually disposed of in a geologic repository. In order to comply with the Waste Acceptance Product Specifications (WAPS), the durability of the glass needs to be measured during production to assure its long term stability and radionuclide release properties. A durability test, designated the Product Consistency Test (PCT), was developed for DWPF glass in order to meet the WAPS requirements. The response of the PCT procedure was based on extensive testing with glasses of widely different compositions. The PCT was determined to be very reproducible, to yield reliable results rapidly, and to be easily performed in shielded cell facilities with radioactive samples. Version 7.0 of the PCT procedure is attached. This draft version has been submitted to ASTM for full committee (C26, Nuclear Fuel Cycle) ballot after being balloted successfully through subcommittee C26.13 on Repository Waste Package Materials Testing

  8. Personal Hypothesis Testing: The Role of Consistency and Self-Schema.

    Science.gov (United States)

    Strohmer, Douglas C.; And Others

    1988-01-01

    Studied how individuals test hypotheses about themselves. Examined extent to which Snyder's bias toward confirmation persists when negative or nonconsistent personal hypothesis is tested. Found negativity or positivity did not affect hypothesis testing directly, though hypothesis consistency did. Found cognitive schematic variable (vulnerability…

  9. Uniform peanut performance test 2017

    Science.gov (United States)

    The Uniform Peanut Performance Tests (UPPT) are designed to evaluate the commercial potential of advanced breeding peanut lines not formally released. The tests are performed in ten locations across the peanut production belt. In this study, 2 controls and 14 entries were evaluated at 8 locations....

  10. GLASS FABRICATION AND PRODUCT CONSISTENCY TESTING OF LANTHANIDE BOROSHILICATE FRIT X COMPOSITION FOR PLUTONIUM DISPOSITION

    Energy Technology Data Exchange (ETDEWEB)

    Marra, J

    2006-11-21

    The Department of Energy Office of Environmental Management (DOE/EM) plans to conduct the Plutonium Disposition Project at the Savannah River Site (SRS) to disposition excess weapons-usable plutonium. A plutonium glass waste form is the preferred option for immobilization of the plutonium for subsequent disposition in a geologic repository. A reference glass composition (Lanthanide Borosilicate (LaBS) Frit B) was developed during the Plutonium Immobilization Program (PIP) to immobilize plutonium in the late 1990's. A limited amount of performance testing was performed on this baseline composition before efforts to further pursue Pu disposition via a glass waste form ceased. Recent FY05 studies have further investigated the LaBS Frit B formulation as well as development of a newer LaBS formulation denoted as LaBS Frit X. The objectives of this present task were to fabricate plutonium loaded LaBS Frit X glass and perform corrosion testing to provide near-term data that will increase confidence that LaBS glass product is suitable for disposal in the Yucca Mountain Repository. Specifically, testing was conducted in an effort to provide data to Yucca Mountain Project (YMP) personnel for use in performance assessment calculations. Plutonium containing LaBS glass with the Frit X composition with a 9.5 wt% PuO{sub 2} loading was prepared for testing. Glass was prepared to support Product Consistency Testing (PCT) at Savannah River National Laboratory (SRNL). The glass was thoroughly characterized using x-ray diffraction (XRD) and scanning electron microscopy coupled with energy dispersive spectroscopy (SEM/EDS) prior to performance testing. A series of PCTs were conducted at SRNL using quenched Pu Frit X glass with varying exposed surface areas. Effects of isothermal and can-in-canister heat treatments on the Pu Frit X glass were also investigated. Another series of PCTs were performed on these different heat-treated Pu Frit X glasses. Leachates from all these PCTs

  11. Consistent Performance Differences between Children and Adults Despite Manipulation of Cue-Target Variables

    Directory of Open Access Journals (Sweden)

    Jessie-Raye Bauer

    2017-08-01

    Full Text Available Two behavioral experiments assessed the plasticity and short-term improvement of task switching in 215 children and adults. Specifically, we studied manipulations of cued attention to different features of a target stimulus as a way to assess the development of cognitive flexibility. Each experiment had multiple levels of difficulty via manipulation of number of cued features (2–4 and number of response options (2 or 4. Working memory demand was manipulated across the two experiments. Impact of memory demand and task level manipulations on task accuracy and response times were measured. There were three overall goals: First, these task manipulations (number of cued features, response choices, and working memory load were tested to assess the stability of group differences in performance between children ages 6–16 years and adults 18–27 years, with the goal of reducing age group differences. Second, age-related transitions to adult-level performance were examined within subgroups of the child sample. Third, short-term improvement from the beginning to the end of the study session was measured to probe whether children can improve with task experience. Attempts to use task manipulations to reduce age differences in cued task switching performance were unsuccessful: children performed consistently worse and were more susceptible to task manipulations than adults. However, across both studies, adult-like performance was observed around mid-adolescence, by ages 13-16 years. Certain task manipulations, especially increasing number of response options when working memory demand was low, produced differences from adults even in the oldest children. Interestingly, there was similar performance improvement with practice for both child and adult groups. The higher memory demand version of the task (Experiment 2 prompted greater short-term improvement in accuracy and response times than the lower memory demand version (Experiment 1. These results

  12. Nonparametric test of consistency between cosmological models and multiband CMB measurements

    Energy Technology Data Exchange (ETDEWEB)

    Aghamousa, Amir [Asia Pacific Center for Theoretical Physics, Pohang, Gyeongbuk 790-784 (Korea, Republic of); Shafieloo, Arman, E-mail: amir@apctp.org, E-mail: shafieloo@kasi.re.kr [Korea Astronomy and Space Science Institute, Daejeon 305-348 (Korea, Republic of)

    2015-06-01

    We present a novel approach to test the consistency of the cosmological models with multiband CMB data using a nonparametric approach. In our analysis we calibrate the REACT (Risk Estimation and Adaptation after Coordinate Transformation) confidence levels associated with distances in function space (confidence distances) based on the Monte Carlo simulations in order to test the consistency of an assumed cosmological model with observation. To show the applicability of our algorithm, we confront Planck 2013 temperature data with concordance model of cosmology considering two different Planck spectra combination. In order to have an accurate quantitative statistical measure to compare between the data and the theoretical expectations, we calibrate REACT confidence distances and perform a bias control using many realizations of the data. Our results in this work using Planck 2013 temperature data put the best fit ΛCDM model at 95% (∼ 2σ) confidence distance from the center of the nonparametric confidence set while repeating the analysis excluding the Planck 217 × 217 GHz spectrum data, the best fit ΛCDM model shifts to 70% (∼ 1σ) confidence distance. The most prominent features in the data deviating from the best fit ΛCDM model seems to be at low multipoles  18 < ℓ < 26 at greater than 2σ, ℓ ∼ 750 at ∼1 to 2σ and ℓ ∼ 1800 at greater than 2σ level. Excluding the 217×217 GHz spectrum the feature at ℓ ∼ 1800 becomes substantially less significance at ∼1 to 2σ confidence level. Results of our analysis based on the new approach we propose in this work are in agreement with other analysis done using alternative methods.

  13. How Well Does the Sum Score Summarize the Test? Summability as a Measure of Internal Consistency

    NARCIS (Netherlands)

    Goeman, J.J.; De, Jong N.H.

    2018-01-01

    Many researchers use Cronbach's alpha to demonstrate internal consistency, even though it has been shown numerous times that Cronbach's alpha is not suitable for this. Because the intention of questionnaire and test constructers is to summarize the test by its overall sum score, we advocate

  14. Compressible Fluid Suspension Performance Testing

    National Research Council Canada - National Science Library

    Hoogterp, Francis

    2003-01-01

    ... compressible fluid suspension system that was designed and installed on the vehicle by DTI. The purpose of the tests was to evaluate the possible performance benefits of the compressible fluid suspension system...

  15. Where Lab Tests Are Performed

    Science.gov (United States)

    ... example, there may be sections that focus on microbiology, hematology, chemistry, and blood banking . Other units may perform highly specialized tests using electron microscopy and immunohistochemistry, and still others ...

  16. Performance testing With JMeter 29

    CERN Document Server

    Erinle, Bayo

    2013-01-01

    Performance Testing With JMeter 2.9 is a standard tutorial that will help you polish your fundamentals, guide you through various advanced topics, and along the process help you learn new tools and skills.This book is for developers, quality assurance engineers, testers, and test managers new to Apache JMeter, or those who are looking to get a good grounding in how to effectively use and become proficient with it. No prior testing experience is required.

  17. Affective-cognitive consistency of attitude as a moderator of the job satisfaction-performance relationship

    Directory of Open Access Journals (Sweden)

    Deléne Visser

    2005-10-01

    Full Text Available Past research has often shown that job satisfaction and job performance are uncorrelated. The current study was an attempt to clarify the relationship by examining the role of affective-cognitive consistency (ACC to test whether attitudinal consistency affects the strength of the relationship. A secondary objective was to assess whether modified versions of the Overall Job Satisfaction Scale (OJS and the Minnesota Satisfaction Questionnaire (MSQ, administered to 166 full-time employees from a variety of companies, may be regarded as affective and cognitive measures of job satisfaction respectively. This view was supported by means of exploratory and confirmatory factor analytic results. Overall job satisfaction was measured by a composite of the modified OJS and MSQ, and job performance was rated on a 10-point scale by the employees’ supervisors. Respondents’ scores on the modified OJS and MSQ were then used to form groups that were high or low in ACC. For employees who displayed high ACC regarding their job satisfaction attitudes, medium to large positive correlations between the job satisfaction measures and performance were obtained. In contrast, non-significant correlations were recorded for the low ACC groups. The hypothesis that ACC is a significant moderator of the relationship between job satisfaction and job performance was therefore supported. Opsomming Vorige navorsing het dikwels getoon dat werktevredenheid en werkprestasie nie korreleer nie. Dié ondersoek was ’n poging om lig te werp op hierdie verwantskap deur die rol van affektiewe-kognitiewe konsekwentheid (AKK te ondersoek ten einde te toets of houdingkonsekwentheid die sterkte van die verwantskap beïnvloed. ’n Sekondêre doelwit was om te bepaal of gewysigde weergawes van die Overall Job Satisfaction Scale (OJS en die Minnesota Satisfaction Questionnaire (MSQ, toegepas op 166 voltydse werknemers van ’n verskeidenheid ondernemings, as affektiewe en kognitiewe metings

  18. Standard Practice for Ensuring Test Consistency in Neutron-Induced Displacement Damage of Electronic Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice sets forth requirements to ensure consistency in neutron-induced displacement damage testing of silicon and gallium arsenide electronic piece parts. This requires controls on facility, dosimetry, tester, and communications processes that affect the accuracy and reproducibility of these tests. It provides background information on the technical basis for the requirements and additional recommendations on neutron testing. In addition to neutrons, reactors are used to provide gamma-ray pulses of intensities and durations that are not achievable elsewhere. This practice also provides background information and recommendations on gamma-ray testing of electronics using nuclear reactors. 1.2 Methods are presented for ensuring and validating consistency in neutron displacement damage testing of electronic parts such as integrated circuits, transistors, and diodes. The issues identified and the controls set forth in this practice address the characterization and suitability of the radiation environm...

  19. Consistency of performance of robot-assisted surgical tasks in virtual reality.

    Science.gov (United States)

    Suh, I H; Siu, K-C; Mukherjee, M; Monk, E; Oleynikov, D; Stergiou, N

    2009-01-01

    The purpose of this study was to investigate consistency of performance of robot-assisted surgical tasks in a virtual reality environment. Eight subjects performed two surgical tasks, bimanual carrying and needle passing, with both the da Vinci surgical robot and a virtual reality equivalent environment. Nonlinear analysis was utilized to evaluate consistency of performance by calculating the regularity and the amount of divergence in the movement trajectories of the surgical instrument tips. Our results revealed that movement patterns for both training tasks were statistically similar between the two environments. Consistency of performance as measured by nonlinear analysis could be an appropriate methodology to evaluate the complexity of the training tasks between actual and virtual environments and assist in developing better surgical training programs.

  20. The eye-complaint questionnaire in a visual display unit work environment: Internal consistency and test-retest reliability

    NARCIS (Netherlands)

    Steenstra, Ivan A.; Sluiter, Judith K.; Frings-Dresen, Monique H. W.

    2009-01-01

    The internal consistency and test-retest reliability of a 10-item eye-complaint questionnaire (ECQ) were examined within a sample of office workers. Repeated within-subjects measures were performed within a single day and over intervals of 1 and 7 d. Questionnaires were completed by 96 workers (70%

  1. NNWSI waste form performance test development

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.

    1984-01-01

    A test method has been developed to measure the release of radionuclides from the waste package under simulated NNWSI repository conditions, and to provide information concerning materials interactions that may occur in the repository. Data from 13 weeks of unsaturated testing are discussed and compared to that from a 13-week analog test. The data indicate that the waste form test is capable of producing consistent, reproducible results that will be useful in evaluating the role of the waste in the long-term performance of the repository. 6 references, 3 figures

  2. Performance Testing of Cutting Fluids

    DEFF Research Database (Denmark)

    Belluco, Walter

    The importance of cutting fluid performance testing has increased with documentation requirements of new cutting fluid formulations based on more sustainable products, as well as cutting with minimum quantity of lubrication and dry cutting. Two sub-problems have to be solved: i) which machining...... tests feature repeatability, reproducibility and sensitivity to cutting fluids, and ii) to what extent results of one test ensure relevance to a wider set of machining situations. The present work is aimed at assessing the range of validity of the different testing methods, investigating correlation...... within the whole range of operations, materials, cutting fluids, operating conditions, etc. Cutting fluid performance was evaluated in turning, drilling, reaming and tapping, and with respect to tool life, cutting forces, chip formation and product quality (dimensional accuracy and surface integrity...

  3. LFK, FORTRAN Application Performance Test

    International Nuclear Information System (INIS)

    McMahon, F.H.

    1991-01-01

    1 - Description of program or function: LFK, the Livermore FORTRAN Kernels, is a computer performance test that measures a realistic floating-point performance range for FORTRAN applications. Informally known as the Livermore Loops test, the LFK test may be used as a computer performance test, as a test of compiler accuracy (via checksums) and efficiency, or as a hardware endurance test. The LFK test, which focuses on FORTRAN as used in computational physics, measures the joint performance of the computer CPU, the compiler, and the computational structures in units of Mega-flops/sec or Mflops. A C language version of subroutine KERNEL is also included which executes 24 samples of C numerical computation. The 24 kernels are a hydrodynamics code fragment, a fragment from an incomplete Cholesky conjugate gradient code, the standard inner product function of linear algebra, a fragment from a banded linear equations routine, a segment of a tridiagonal elimination routine, an example of a general linear recurrence equation, an equation of state fragment, part of an alternating direction implicit integration code, an integrate predictor code, a difference predictor code, a first sum, a first difference, a fragment from a two-dimensional particle-in-cell code, a part of a one-dimensional particle-in-cell code, an example of how casually FORTRAN can be written, a Monte Carlo search loop, an example of an implicit conditional computation, a fragment of a two-dimensional explicit hydrodynamics code, a general linear recurrence equation, part of a discrete ordinates transport program, a simple matrix calculation, a segment of a Planck distribution procedure, a two-dimensional implicit hydrodynamics fragment, and determination of the location of the first minimum in an array. 2 - Method of solution: CPU performance rates depend strongly on the maturity of FORTRAN compiler machine code optimization. The LFK test-bed executes the set of 24 kernels three times, resetting the DO

  4. Radioactive material packaging performance testing

    International Nuclear Information System (INIS)

    Romano, T.; Cruse, J.M.

    1991-02-01

    To provide uniform packaging of hazardous materials on an international level, the United Nations has developed packaging recommendations that have been implemented worldwide. The United Nations packaging recommendations are performance oriented, allowing for a wide variety of package materials and systems. As a result of this international standard, efforts in the United States are being directed toward use of performance-oriented packaging and elimination of specification (designed) packaging. This presentation will focus on trends, design evaluation, and performance testing of radioactive material packaging. The impacts of US Department of Transportation Dockets HM-181 and HM-169A on specification and low-specific activity radioactive material packaging requirements are briefly discussed. The US Department of Energy's program for evaluating radioactive material packings per US Department of Transportation Specification 7A Type A requirements, is used as the basis for discussing low-activity packaging performance test requirements. High-activity package testing requirements are presented with examples of testing performed at the Hanford Site that is operated by Westinghouse Hanford Company for the US Department of Energy. 5 refs., 2 tabs

  5. Requirements for UML and OWL Integration Tool for User Data Consistency Modeling and Testing

    DEFF Research Database (Denmark)

    Nytun, J. P.; Jensen, Christian Søndergaard; Oleshchuk, V. A.

    2003-01-01

    The amount of data available on the Internet is continuously increasing, consequentially there is a growing need for tools that help to analyse the data. Testing of consistency among data received from different sources is made difficult by the number of different languages and schemas being used....... In this paper we analyze requirements for a tool that support integration of UML models and ontologies written in languages like the W3C Web Ontology Language (OWL). The tool can be used in the following way: after loading two legacy models into the tool, the tool user connects them by inserting modeling......, an important part of this technique is attaching of OCL expressions to special boolean class attributes that we call consistency attributes. The resulting integration model can be used for automatic consistency testing of two instances of the legacy models by automatically instantiate the whole integration...

  6. Leaching characteristics of the metal waste form from the electrometallurgical treatment process: Product consistency testing

    International Nuclear Information System (INIS)

    Johnson, S. G.; Keiser, D. D.; Frank, S. M.; DiSanto, T.; Noy, M.

    1999-01-01

    Argonne National Laboratory is developing an electrometallurgical treatment for spent fuel from the experimental breeder reactor II. A product of this treatment process is a metal waste form that incorporates the stainless steel cladding hulls, zirconium from the fuel and the fission products that are noble to the process, i.e., Tc, Ru, Nb, Pd, Rh, Ag. The nominal composition of this waste form is stainless steel/15 wt% zirconium/1--4 wt% noble metal fission products/1--2 wt % U. Leaching results are presented from several tests and sample types: (1) 2 week monolithic immersion tests on actual metal waste forms produced from irradiated cladding hulls, (2) long term (>2 years) pulsed flow tests on samples containing technetium and uranium and (3) crushed sample immersion tests on cold simulated metal waste form samples. The test results will be compared and their relevance for waste form product consistency testing discussed

  7. Method used to test the imaging consistency of binocular camera's left-right optical system

    Science.gov (United States)

    Liu, Meiying; Wang, Hu; Liu, Jie; Xue, Yaoke; Yang, Shaodong; Zhao, Hui

    2016-09-01

    To binocular camera, the consistency of optical parameters of the left and the right optical system is an important factor that will influence the overall imaging consistency. In conventional testing procedure of optical system, there lacks specifications suitable for evaluating imaging consistency. In this paper, considering the special requirements of binocular optical imaging system, a method used to measure the imaging consistency of binocular camera is presented. Based on this method, a measurement system which is composed of an integrating sphere, a rotary table and a CMOS camera has been established. First, let the left and the right optical system capture images in normal exposure time under the same condition. Second, a contour image is obtained based on the multiple threshold segmentation result and the boundary is determined using the slope of contour lines near the pseudo-contour line. Third, the constraint of gray level based on the corresponding coordinates of left-right images is established and the imaging consistency could be evaluated through standard deviation σ of the imaging grayscale difference D (x, y) between the left and right optical system. The experiments demonstrate that the method is suitable for carrying out the imaging consistency testing for binocular camera. When the standard deviation 3σ distribution of imaging gray difference D (x, y) between the left and right optical system of the binocular camera does not exceed 5%, it is believed that the design requirements have been achieved. This method could be used effectively and paves the way for the imaging consistency testing of the binocular camera.

  8. GEM: Performance and aging tests

    International Nuclear Information System (INIS)

    Cho, H.S.; Kadyk, J.; Han, S.H.; Hong, W.S.; Perez-Mendez, V.; Wenzel, W.; Pitts, K.; Martin, M.D.; Hutchins, J.B.

    1999-01-01

    Performance and aging tests have been done to characterize Gas Electron Multipliers (GEMs), including further design improvements such as a thicker GEM and a closed GEM. Since the effective GEM gain is typically smaller than the absolute GEM gain, due to trapping of avalanche electrons at the bottom GEM electrode, the authors performed field simulations and measurements for better understanding, and discuss methods to eliminate this effect. Other performance parameters of the GEMs are also presented, including absolute GEM gain, short-term and long-term gain stabilities

  9. On the Consistency of Bootstrap Testing for a Parameter on the Boundary of the Parameter Space

    DEFF Research Database (Denmark)

    Cavaliere, Giuseppe; Nielsen, Heino Bohn; Rahbek, Anders

    2017-01-01

    It is well known that with a parameter on the boundary of the parameter space, such as in the classic cases of testing for a zero location parameter or no autoregressive conditional heteroskedasticity (ARCH) effects, the classic nonparametric bootstrap – based on unrestricted parameter estimates...... – leads to inconsistent testing. In contrast, we show here that for the two aforementioned cases, a nonparametric bootstrap test based on parameter estimates obtained under the null – referred to as ‘restricted bootstrap’ – is indeed consistent. While the restricted bootstrap is simple to implement...... in practice, novel theoretical arguments are required in order to establish consistency. In particular, since the bootstrap is analysed both under the null hypothesis and under the alternative, non-standard asymptotic expansions are required to deal with parameters on the boundary. Detailed proofs...

  10. Remaining useful life prediction based on variation coefficient consistency test of a Wiener process

    Directory of Open Access Journals (Sweden)

    Juan LI

    2018-01-01

    Full Text Available High-cost equipment is often reused after maintenance, and whether the information before the maintenance can be used for the Remaining Useful Life (RUL prediction after the maintenance is directly determined by the consistency of the degradation pattern before and after the maintenance. Aiming at this problem, an RUL prediction method based on the consistency test of a Wiener process is proposed. Firstly, the parameters of the Wiener process estimated by Maximum Likelihood Estimation (MLE are proved to be biased, and a modified unbiased estimation method is proposed and verified by derivation and simulations. Then, the h statistic is constructed according to the reciprocal of the variation coefficient of the Wiener process, and the sampling distribution is derived. Meanwhile, a universal method for the consistency test is proposed based on the sampling distribution theorem, which is verified by simulation data and classical crack degradation data. Finally, based on the consistency test of the degradation model, a weighted fusion RUL prediction method is presented for the fuel pump of an airplane, and the validity of the presented method is verified by accurate computation results of real data, which provides a theoretical and practical guidance for engineers to predict the RUL of equipment after maintenance.

  11. Internal Consistency of Performance Evaluations as a Function of Music Expertise and Excerpt Familiarity

    Science.gov (United States)

    Kinney, Daryl W.

    2009-01-01

    The purpose of this study was to examine the effects of music experience and excerpt familiarity on the internal consistency of performance evaluations. Participants included nonmusic majors who had not participated in high school music ensembles, nonmusic majors who had participated in high school music ensembles, music majors, and experts…

  12. Vibrational multiconfiguration self-consistent field theory: implementation and test calculations.

    Science.gov (United States)

    Heislbetz, Sandra; Rauhut, Guntram

    2010-03-28

    A state-specific vibrational multiconfiguration self-consistent field (VMCSCF) approach based on a multimode expansion of the potential energy surface is presented for the accurate calculation of anharmonic vibrational spectra. As a special case of this general approach vibrational complete active space self-consistent field calculations will be discussed. The latter method shows better convergence than the general VMCSCF approach and must be considered the preferred choice within the multiconfigurational framework. Benchmark calculations are provided for a small set of test molecules.

  13. The internal consistency of the standard gamble: tests after adjusting for prospect theory.

    Science.gov (United States)

    Oliver, Adam

    2003-07-01

    This article reports a study that tests whether the internal consistency of the standard gamble can be improved upon by incorporating loss weighting and probability transformation parameters in the standard gamble valuation procedure. Five alternatives to the standard EU formulation are considered: (1) probability transformation within an EU framework; and, within a prospect theory framework, (2) loss weighting and full probability transformation, (3) no loss weighting and full probability transformation, (4) loss weighting and no probability transformation, and (5) loss weighting and partial probability transformation. Of the five alternatives, only the prospect theory formulation with loss weighting and no probability transformation offers an improvement in internal consistency over the standard EU valuation procedure.

  14. Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  15. Test Driven Development: Performing Art

    Science.gov (United States)

    Bache, Emily

    The art of Test Driven Development (TDD) is a skill that needs to be learnt, and which needs time and practice to master. In this workshop a select number of conference participants with considerable skill and experience are invited to perform code katas [1]. The aim is for them to demonstrate excellence and the use of Test Driven Development, and result in some high quality code. This would be for the benefit of the many programmers attending the conference, who could come along and witness high quality code being written using TDD, and get a chance to ask questions and provide feedback.

  16. A non-parametric consistency test of the ΛCDM model with Planck CMB data

    Energy Technology Data Exchange (ETDEWEB)

    Aghamousa, Amir; Shafieloo, Arman [Korea Astronomy and Space Science Institute, Daejeon 305-348 (Korea, Republic of); Hamann, Jan, E-mail: amir@aghamousa.com, E-mail: jan.hamann@unsw.edu.au, E-mail: shafieloo@kasi.re.kr [School of Physics, The University of New South Wales, Sydney NSW 2052 (Australia)

    2017-09-01

    Non-parametric reconstruction methods, such as Gaussian process (GP) regression, provide a model-independent way of estimating an underlying function and its uncertainty from noisy data. We demonstrate how GP-reconstruction can be used as a consistency test between a given data set and a specific model by looking for structures in the residuals of the data with respect to the model's best-fit. Applying this formalism to the Planck temperature and polarisation power spectrum measurements, we test their global consistency with the predictions of the base ΛCDM model. Our results do not show any serious inconsistencies, lending further support to the interpretation of the base ΛCDM model as cosmology's gold standard.

  17. Chemical Composition Analysis and Product Consistency Tests of the ORP Phase 5 Nepheline Study Glasses

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Caldwell, M. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Riley, W. T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2018-02-01

    In this report, the Savannah River National Laboratory (SRNL) provides chemical analyses and Product Consistency Test (PCT) results for a series of simulated high-level waste glass compositions fabricated by the Pacific Northwest National Laboratory (PNNL). These data will be used in the development of improved models for the prediction of nepheline crystallization in support of the Hanford Tank Waste Treatment and Immobilization Plant (WTP).

  18. Radioactive material packaging performance testing

    International Nuclear Information System (INIS)

    Romano, T.

    1992-06-01

    In an effort to provide uniform packaging of hazardous material on an international level, recommendations for the transport of dangerous goods have been developed by the United Nations. These recommendations are performance oriented and contrast with a large number of packaging specifications in the US Department of Transportation's hazard materials regulations. This dual system presents problems when international shipments enter the US Department of Transportation's system. Faced with the question of continuing a dual system or aligning with the international system, the Research and Special Programs Administration of the US Department of Transportation responded with Docket HM-181. This began the transition toward the international transportation system. Following close behind is Docket HM-169A, which addressed low specific activity radioactive material packaging. This paper will discuss the differences between performance-oriented and specification packaging, the transition toward performance-oriented packaging by the US Department of Transportation, and performance-oriented testing of radioactive material packaging by Westinghouse Hanford Company. Dockets HM-181 and HM-169A will be discussed along with Type A (low activity) and Type B (high activity) radioactive material packaging evaluations

  19. Thermodynamic consistency test procedure using orthogonal collocation and the Peng-Robinson equation of state

    International Nuclear Information System (INIS)

    Hamm, L.L.; Van Brunt, V.

    1982-08-01

    The Christiansen and Fredenslund programs for calculating vapor-liquid equilibria have been modified by replacing the Soave-Redlich-Kwong equation of state with the newly developed Peng-Robinson equation of state. This modification was shown to be a decided improvement for high pressure systems, especially in the critical and upper retrograde regions. Thermodynamic consistency tests were developed and used to evaluate and compare calculated values from both the modified and unmodified programs with reported experimental data for several vapor-liquid systems

  20. Performance testing of extremity dosimeters, Study 2

    International Nuclear Information System (INIS)

    Harty, R.; Reece, W.D.; Hooker, C.D.

    1990-04-01

    The Health Physics Society Standards Committee (HPSSC) Working Group on Performance Testing of Extremity Dosimeters has issued a draft of a proposed standard for extremity dosimeters. The draft standard proposes methods to be used for testing dosimetry systems that determine occupational radiation dose to the extremities and the performance criterion used to determine compliance with the standard. Pacific Northwest Laboratory (PNL) has conducted two separate evaluations of the performance of extremity dosimeter processors to determine the appropriateness of the draft standard, as well as to obtain information regarding the performance of extremity dosimeters. Based on the information obtained during the facility visits and the results obtained from the performance testing, it was recommended that changes be made to ensure that the draft standard is appropriate for extremity dosimeters. The changes include: subdividing the mixture category and the beta particle category; eliminating the neutron category until appropriate flux-to-dose equivalent conversion factors are derived; and changing the tolerance level for the performance criterion to provide consistency with the performance criterion for whole body dosimeters, and to avoid making the draft standard overly difficult for processors of extremity dosimeters to pass. 20 refs., 10 figs., 6 tabs

  1. Visual perspective in autobiographical memories: reliability, consistency, and relationship to objective memory performance.

    Science.gov (United States)

    Siedlecki, Karen L

    2015-01-01

    Visual perspective in autobiographical memories was examined in terms of reliability, consistency, and relationship to objective memory performance in a sample of 99 individuals. Autobiographical memories may be recalled from two visual perspectives--a field perspective in which individuals experience the memory through their own eyes, or an observer perspective in which individuals experience the memory from the viewpoint of an observer in which they can see themselves. Participants recalled nine word-cued memories that differed in emotional valence (positive, negative and neutral) and rated their memories on 18 scales. Results indicate that visual perspective was the most reliable memory characteristic overall and is consistently related to emotional intensity at the time of recall and amount of emotion experienced during the memory. Visual perspective is unrelated to memory for words, stories, abstract line drawings or faces.

  2. Design of next step tokamak: Consistent analysis of plasma performance flux composition and poloidal field system

    International Nuclear Information System (INIS)

    Ane, J.M.; Grandgirard, V.; Albajar, F.; Johner, J.

    2001-01-01

    A consistent and simple approach to derive plasma scenarios for next step tokamak design is presented. It is based on successive plasma equilibria snapshots from plasma breakdown to end of ramp-down. Temperature and density profiles for each equilibrium are derived from a 2D plasma model. The time interval between two successive equilibria is then computed from the toroidal field magnetic energy balance, the resistive term of which depends on n, T profiles. This approach provides a consistent analysis of plasma performance, flux consumption and PF system, including average voltages waveforms across the PF coils. The plasma model and the Poynting theorem for the toroidal magnetic energy are presented. Application to ITER-FEAT and to M2, a Q=5 machine designed at CEA, are shown. (author)

  3. Standard test methods for determining chemical durability of nuclear, hazardous, and mixed waste glasses and multiphase glass ceramics: The product consistency test (PCT)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 These product consistency test methods A and B evaluate the chemical durability of homogeneous glasses, phase separated glasses, devitrified glasses, glass ceramics, and/or multiphase glass ceramic waste forms hereafter collectively referred to as “glass waste forms” by measuring the concentrations of the chemical species released to a test solution. 1.1.1 Test Method A is a seven-day chemical durability test performed at 90 ± 2°C in a leachant of ASTM-Type I water. The test method is static and conducted in stainless steel vessels. Test Method A can specifically be used to evaluate whether the chemical durability and elemental release characteristics of nuclear, hazardous, and mixed glass waste forms have been consistently controlled during production. This test method is applicable to radioactive and simulated glass waste forms as defined above. 1.1.2 Test Method B is a durability test that allows testing at various test durations, test temperatures, mesh size, mass of sample, leachant volume, a...

  4. Product consistency testing of three reference glasses in stainless steel and perfluoroalkoxy resin vessels

    International Nuclear Information System (INIS)

    Olson, K.M.; Smith, G.L.; Marschman, S.C.

    1995-03-01

    Because of their chemical durability, silicate glasses have been proposed and researched since the mid-1950s as a medium for incorporating high-level radioactive waste (HLW) generated from processing of nuclear materials. A number of different waste forms were evaluated and ranked in the early 1980s; durability (leach resistance) was the highest weighted factor. Borosilicate glass was rated the best waste form available for incorporation of HLW. Four different types of vessels and three different glasses were used to study the possible effect of vessel composition on durability test results from the Production Consistency Test (PCT). The vessels were 45-m 304 stainless steel vessels, 150-m 304 L stainless steel vessels, and 60-m perfluoroalkoxy (PFA) fluoropolymer resin vessels. The three glasses were the Environmental Assessment glass manufactured by Corning Incorporated and supplied by Westinghouse Savannah River company, and West Valley Nuclear Services reference glasses 5 and 6, manufactured and supplied by Catholic University of America. Within experimental error, no differences were found in durability test results using the 3 different glasses in the 304L stainless steel or PFA fluoropolymer resin vessels over the seven-day test period

  5. Test Performance Related Dysfunctional Beliefs

    Directory of Open Access Journals (Sweden)

    Recep TÜTÜNCÜ

    2012-11-01

    Full Text Available Objective: Examinations by using tests are very frequently used in educational settings and successful studying before the examinations is a complex matter to deal with. In order to understand the determinants of success in exams better, we need to take into account not only emotional and motivational, but also cognitive aspects of the participants such as dysfunctional beliefs. Our aim is to present the relationship between candidates’ characteristics and distorted beliefs/schemata just before an examination. Method: The subjects of the study were 30 female and 30 male physicians who were about to take the medical specialization exam (MSE in Turkey. Dysfunctional Attitude Scale (DAS and Young Schema Questionnaire Short Form (YSQ-SF were applied to the subjects. The statistical analysis was done using the F test, Mann-Whitney, Kruskal-Wallis, chi-square test and spearman’s correlation test. Results: It was shown that some of the DAS and YSQ-SF scores were significantly higher in female gender, in the group who could not pass the exam, who had repetitive examinations, who had their first try taking an examination and who were unemployed at the time of the examination. Conclusion: Our findings indicate that candidates seeking help before MSE examination could be referred for cognitive therapy or counseling even they do not have any psychiatric diagnosis due to clinically significant cognitive distortion. Measurement and treatment of cognitive distortions that have negative impact on MSE performance may improve the cost-effectiveness and mental well being of the young doctors.

  6. Load responsive multilayer insulation performance testing

    International Nuclear Information System (INIS)

    Dye, S.; Kopelove, A.; Mills, G. L.

    2014-01-01

    Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI

  7. Load responsive multilayer insulation performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Dye, S.; Kopelove, A. [Quest Thermal Group, 6452 Fig Street Suite A, Arvada, CO 80004 (United States); Mills, G. L. [Ball Aerospace and Technologies Corp, 1600 Commerce Street, Boulder, CO 80301 (United States)

    2014-01-29

    Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.

  8. Performance Analysis of Thermoelectric Modules Consisting of Square Truncated Pyramid Elements Under Constant Heat Flux

    Science.gov (United States)

    Oki, Sae; Natsui, Shungo; Suzuki, Ryosuke O.

    2018-06-01

    System design of a thermoelectric (TE) power generation module is pursued in order to improve the TE performance. Square truncated pyramid shaped P-N pairs of TE elements are connected electronically in series in the open space between two flat insulator boards. The performance of the TE module consisting of 2-paired elements is numerically simulated using commercial software and original TE programs. Assuming that the heat radiating into the hot surface is regulated, i.e., the amount of heat from the hot surface to the cold one is steadily constant, as it happens for solar radiation heating, the performance is significantly improved by changing the shape and the alignment pattern of the elements. When the angle θ between the edge and the base is smaller than 72°, and when the cold surface is kept at a constant temperature, two patterns in particular, amongst the 17 studied, show the largest TE power and efficiency. In comparison to other geometries, the smarter square truncated pyramid shape can provide higher performance using a large cold bath and constant heat transfer by heat radiation.

  9. Evaluating the Consistency of the FNA Test in Pathologically Proven Nodules of Thyroidectomy

    Directory of Open Access Journals (Sweden)

    Alireza Khazaei

    2018-02-01

    Full Text Available Fine Needle Aspiration (FNA is a selective diagnostic technique for the evaluation of non-toxic thyroid nodules. Thyroid FNA results are either undiagnosed or suspicious and indeterminate in 20-30% of cases. Therefore, this study seeks to determine the consistency of the FNA test in pathologically proven nodules of thyroidectomy. This is a descriptive cross-sectional study carried out on a total of 73 candidates for thyroidectomy who had been admitted to Imam Ali Hospital. A census sampling method has been used in this study. The FNA samples and pathology samples were evaluated and the consistency of the FNA test in pathologically proven nodules were compared. The SPSS software was used for data analysis. The mean age of the patients was 40.1 ± 12.9 years. 23.3% of the participants were male and 76.7% of them were female. The malignancy rate in the pathology was 65.8% (48 cases and 53.4% (39 cases in the FNA. Of the 48 positive cases, the FNA pathology diagnosed 35 cases (72.9% as positive and 13 cases (27.1% as negative. Of the 25 negative cases, the FNA pathology diagnosed 21 cases (84% as negative and 4 cases (16% as positive. Sensitivity, specificity, positive and negative predictive values of FNA in malignancy diagnosis were 72.92, 84, 89.74, and 61.76%, respectively. The results show that FNA does not have a high sensitivity in the diagnosis of malignancy, but has good specificity and the use of other diagnostic methods before the operation of thyroid nodules seems necessary.

  10. 40 CFR 60.8 - Performance tests.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Performance tests. 60.8 Section 60.8... PERFORMANCE FOR NEW STATIONARY SOURCES General Provisions § 60.8 Performance tests. (a) Except as specified in... conduct performance test(s) and furnish the Administrator a written report of the results of such...

  11. Evaluation of uniformity and noise consistency test in computerized tomography; Avaliacao do teste de constancia de uniformidade e ruido em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Garrafiel, Fabricio N.; Lykawka, Rochelle; Bacelar, Alexandre; Anes, Mauricio [Hospital de Clinicas de Porto Alegre (HCPA), Porto Alegre, RS (Brazil); Alva-Sanchez, Mirko S.; Pianoschi, Thatiane [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), Porto Alegre, RS (Brazil)

    2016-07-01

    The quality control in computed tomography (CT) includes constancy tests concerning CT number measured in a water tank and its response as uniformity, noise and accuracy. Differences to It's performance limits and frequency established by the national legislation and the manufacturers are well known. The objective of this study was to evaluate these tests proceeding the periodicity of national legislation. The tests were conducted over a three equipment of different manufacturers. Each equipment has acquisition parameters and specific phantoms. The equipment presented adequate performance and consistency when compared their results to the limits determined by manufacturers and national legislation. Thus, it is important to evaluate these differences and tailor the testing protocols to meet the established quality requirements. (author)

  12. REFINEMENT OF THE REVERSE EXTRUSION TEST TO DETERMINE THE TWO CONSISTENCY LIMITS

    Directory of Open Access Journals (Sweden)

    Kamil KAYABALI

    2015-11-01

    coefficients (i.e., a and b were subjected to a multiple regression analysis along with the results of the conventional testing methods of fall-cone and rolling-device to determine the LL and PL as functions of the reverse extrusion parameters. It was shown that LL and PL can be predicted with a great degree of success using the reverse extrusion coefficients. While a great majority of the liquid limits found by using the fall-cone method were predicted with a ±10% error, almost all of the plastic limits found by the rolling device were predicted with a ±10% error. This refined investigation on the reverse extrusion test confirmed and proved that the reverse extrusion test is a simple, robust and inexpensive method capable of predicting both of two fundamental consistency limits using a single device.

  13. Nuclear material control and accountancy planning and performance testing

    International Nuclear Information System (INIS)

    Mike Enhinger; Dennis Wilkey; Rod Martin; Ken Byers; Brian Smith

    1999-01-01

    An overview of performance testing as used at U.S. Department of Energy facilities is provided. Performance tests are performed on specific aspects of the regulations or site policy. The key issues in establishing a performance testing program are: identifying what needs to be tested; determining how to test; establishing criteria to evaluate test results. The program elements of performance testing program consist of: planning; coordination; conduct; evaluation. A performance test may be conducted of personnel or equipment. The DOE orders for nuclear material control and accountancy are divided into three functional areas: program administration, material accounting, and material control. Examples performance tests may be conducted on program administration, accounting, measurement and measurement control, inventory, and containment [ru

  14. Stereotype Threat, Test Anxiety, and Mathematics Performance

    Science.gov (United States)

    Tempel, Tobias; Neumann, Roland

    2014-01-01

    We investigated the combined effects of stereotype threat and trait test anxiety on mathematics test performance. Stereotype threat and test anxiety interacted with each other in affecting performance. Trait test anxiety predicted performance only in a diagnostic condition that prevented stereotype threat by stereotype denial. A state measure of…

  15. Culture, Cross-Role Consistency, and Adjustment: Testing Trait and Cultural Psychology Perspectives

    OpenAIRE

    Church, A. Timothy; Anderson-Harumi, Cheryl A.; del Prado, Alicia M.; Curtis, Guy J.; Tanaka-Matsumi, Junko; Valdez Medina, José L.; Mastor, Khairul A.; White, Fiona A.; Miramontes, Lilia A.; Katigbak, Marcia S.

    2008-01-01

    Trait and cultural psychology perspectives on cross-role consistency and its relation to adjustment were examined in two individualistic cultures, the United States (N = 231) and Australia (N = 195), and four collectivistic cultures, Mexico (N = 199), Philippines (N = 195), Malaysia (N = 217), and Japan (N = 180). Cross-role consistency in trait ratings was evident in all cultures, supporting trait perspectives. Cultural comparisons of mean consistency provided support for cultural psychology...

  16. Operator performance in non-destructive testing: A study of operator performance in a performance test

    Energy Technology Data Exchange (ETDEWEB)

    Enkvist, J.; Edland, A.; Svenson, Ola [Stockholm Univ. (Sweden). Dept. of Psychology

    2000-05-15

    In the process industries there is a need of inspecting the integrity of critical components without disrupting the process. Such in-service inspections are typically performed with non-destructive testing (NDT). In NDT the task of the operator is to (based on diagnostic information) decide if the component can remain in service or not. The present study looks at the performance in NDT. The aim is to improve performance, in the long run, by exploring the operators' decision strategies and other underlying factors and to this way find out what makes some operators more successful than others. Sixteen operators performed manual ultrasonic inspections of four test pieces with the aim to detect (implanted) cracks. In addition to these performance demonstration tests (PDT), the operators performed independent ability tests and filled out questionnaires. The results show that operators who trust their gut feeling more than the procedure (when the two come to different results) and that at the same time have a positive attitude towards the procedure have a higher PDT performance. These results indicate the need for operators to be motivated and confident when performing NDT. It was also found that the operators who performed better rated more decision criteria higher in the detection phase than the operators who performed worse. For characterizing it was the other way around. Also, the operators who performed better used more time, both detecting and characterizing, than the operators who performed worse.

  17. Operator performance in non-destructive testing: A study of operator performance in a performance test

    International Nuclear Information System (INIS)

    Enkvist, J.; Edland, A.; Svenson, Ola

    2000-05-01

    In the process industries there is a need of inspecting the integrity of critical components without disrupting the process. Such in-service inspections are typically performed with non-destructive testing (NDT). In NDT the task of the operator is to (based on diagnostic information) decide if the component can remain in service or not. The present study looks at the performance in NDT. The aim is to improve performance, in the long run, by exploring the operators' decision strategies and other underlying factors and to this way find out what makes some operators more successful than others. Sixteen operators performed manual ultrasonic inspections of four test pieces with the aim to detect (implanted) cracks. In addition to these performance demonstration tests (PDT), the operators performed independent ability tests and filled out questionnaires. The results show that operators who trust their gut feeling more than the procedure (when the two come to different results) and that at the same time have a positive attitude towards the procedure have a higher PDT performance. These results indicate the need for operators to be motivated and confident when performing NDT. It was also found that the operators who performed better rated more decision criteria higher in the detection phase than the operators who performed worse. For characterizing it was the other way around. Also, the operators who performed better used more time, both detecting and characterizing, than the operators who performed worse

  18. Force Concept Inventory-Based Multiple-Choice Test for Investigating Students' Representational Consistency

    Science.gov (United States)

    Nieminen, Pasi; Savinainen, Antti; Viiri, Jouni

    2010-01-01

    This study investigates students' ability to interpret multiple representations consistently (i.e., representational consistency) in the context of the force concept. For this purpose we developed the Representational Variant of the Force Concept Inventory (R-FCI), which makes use of nine items from the 1995 version of the Force Concept Inventory…

  19. Ecotoxicological testing of performance fluids

    International Nuclear Information System (INIS)

    Kallqvist, T.

    1990-05-01

    The report deals with a project comprising the testing of drilling fluids concerning ecotoxicology, biological degradation, and toxicity. Two types of drilling fluids were tested for toxic effects on marine algae and biological degradability. A fluid based on mineral oil was readily degradable (98% DOC removal in 28 days) while an ether based oil degraded more slowly (56% DOC removal in 28 days). The toxicity of both fluids was tested after emulsification of the oils in water and separating the oil and water phase after equilibration. The EC 50 values obtained with this approach were 8.15 g/l for the oil based fluid and 116 g/l for the ether fluid. 9 figs., 8 tabs

  20. Determining the dissolution rates of actinide glasses: A time and temperature Product Consistency Test study

    International Nuclear Information System (INIS)

    Daniel, W.E.; Best, D.R.

    1995-01-01

    Vitrification has been identified as one potential option for the e materials such as Americium (Am), Curium (Cm), Neptunium (Np), and Plutonium (Pu). A process is being developed at the Savannah River Site to safely vitrify all of the highly radioactive Am/Cm material and a portion of the fissile (Pu) actinide materials stored on site. Vitrification of the Am/Cm will allow the material to be transported and easily stored at the Oak Ridge National Laboratory. The Am/Cm glass has been specifically designed to be (1) highly durable in aqueous environments and (2) selectively attacked by nitric acid to allow recovery of the valuable Am and Cm isotopes. A similar glass composition will allow for safe storage of surplus plutonium. This paper will address the composition, relative durability, and dissolution rate characteristics of the actinide glass, Loeffler Target, that will be used in the Americium/Curium Vitrification Project at Westinghouse Savannah River Company near Aiken, South Carolina. The first part discusses the tests performed on the Loeffler Target Glass concerning instantaneous dissolution rates. The second part presents information concerning pseudo-activation energy for the one week glass dissolution process

  1. On Consistency Test Method of Expert Opinion in Ecological Security Assessment.

    Science.gov (United States)

    Gong, Zaiwu; Wang, Lihong

    2017-09-04

    To reflect the initiative design and initiative of human security management and safety warning, ecological safety assessment is of great value. In the comprehensive evaluation of regional ecological security with the participation of experts, the expert's individual judgment level, ability and the consistency of the expert's overall opinion will have a very important influence on the evaluation result. This paper studies the consistency measure and consensus measure based on the multiplicative and additive consistency property of fuzzy preference relation (FPR). We firstly propose the optimization methods to obtain the optimal multiplicative consistent and additively consistent FPRs of individual and group judgments, respectively. Then, we put forward a consistency measure by computing the distance between the original individual judgment and the optimal individual estimation, along with a consensus measure by computing the distance between the original collective judgment and the optimal collective estimation. In the end, we make a case study on ecological security for five cities. Result shows that the optimal FPRs are helpful in measuring the consistency degree of individual judgment and the consensus degree of collective judgment.

  2. Long-term product consistency test of simulated 90-19/Nd HLW glass

    International Nuclear Information System (INIS)

    Gan, X.Y.; Zhang, Z.T.; Yuan, W.Y.; Wang, L.; Bai, Y.; Ma, H.

    2011-01-01

    Chemical durability of 90-19/Nd glass, a simulated high-level waste (HLW) glass in contact with the groundwater was investigated with a long-term product consistency test (PCT). Generally, it is difficult to observe the long term property of HLW glass due to the slow corrosion rate in a mild condition. In order to overcome this problem, increased contacting surface (S/V = 6000 m -1 ) and elevated temperature (150 o C) were employed to accelerate the glass corrosion evolution. The micro-morphological characteristics of the glass surface and the secondary minerals formed after the glass alteration were analyzed by SEM-EDS and XRD, and concentrations of elements in the leaching solution were determined by ICP-AES. In our experiments, two types of minerals, which have great impact on glass dissolution, were found to form on 90-19/Nd HLW glass surface when it was subjected to a long-term leaching in the groundwater. One is Mg-Fe-rich phyllosilicates with honeycomb structure; the other is aluminosilicates (zeolites). Mg and Fe in the leaching solution participated in the formation of phyllosilicates. The main components of phyllosilicates in alteration products of 90-19/Nd HLW glass are nontronite (Na 0.3 Fe 2 Si 4 O 10 (OH) 2 .4H 2 O) and montmorillonite (Ca 0.2 (Al,Mg) 2 Si 4 O 10 (OH) 2 .4H 2 O), and those of aluminosilicates are mordenite ((Na 2 ,K 2 ,Ca)Al 2 Si 10 O 24 .7H 2 O)) and clinoptilolite ((Na,K,Ca) 5 Al 6 Si 30 O 72 .18H 2 O). Minerals like Ca(Mg)SO 4 and CaCO 3 with low solubility limits are prone to form precipitant on the glass surface. Appearance of the phyllosilicates and aluminosilicates result in the dissolution rate of 90-19/Nd HLW glass resumed, which is increased by several times over the stable rate. As further dissolution of the glass, both B and Na in the glass were found to leach out in borax form.

  3. Do Different Tests of Episodic Memory Produce Consistent Results in Human Adults?

    Science.gov (United States)

    Cheke, Lucy G.; Clayton, Nicola S.

    2013-01-01

    A number of different philosophical, theoretical, and empirical perspectives on episodic memory have led to the development of very different tests with which to assess it. Although these tests putatively assess the same psychological capacity, they have rarely been directly compared. Here, a sample of undergraduates was tested on three different…

  4. Culture, cross-role consistency, and adjustment: testing trait and cultural psychology perspectives.

    Science.gov (United States)

    Church, A Timothy; Anderson-Harumi, Cheryl A; del Prado, Alicia M; Curtis, Guy J; Tanaka-Matsumi, Junko; Valdez Medina, José L; Mastor, Khairul A; White, Fiona A; Miramontes, Lilia A; Katigbak, Marcia S

    2008-09-01

    Trait and cultural psychology perspectives on cross-role consistency and its relation to adjustment were examined in 2 individualistic cultures, the United States (N=231) and Australia (N=195), and 4 collectivistic cultures, Mexico (N=199), the Philippines (N=195), Malaysia (N=217), and Japan (N=180). Cross-role consistency in trait ratings was evident in all cultures, supporting trait perspectives. Cultural comparisons of mean consistency provided support for cultural psychology perspectives as applied to East Asian cultures (i.e., Japan) but not collectivistic cultures more generally. Some but not all of the hypothesized predictors of consistency were supported across cultures. Cross-role consistency predicted aspects of adjustment in all cultures, but prediction was most reliable in the U.S. sample and weakest in the Japanese sample. Alternative constructs proposed by cultural psychologists--personality coherence, social appraisal, and relationship harmony--predicted adjustment in all cultures but were not, as hypothesized, better predictors of adjustment in collectivistic cultures than in individualistic cultures.

  5. Swift and Certain, Proportionate and Consistent: Key Values of Urine Drug Test Consequences for Probationers.

    Science.gov (United States)

    Cadwallader, Amy B

    2017-09-01

    Traditionally, urine drug testing (UDT) in the correctional population (both prison and community corrections) has been infrequent, is scheduled, and has a high possibility of delayed results. Of practical relevance is that scheduled testing is ineffective for identifying drug misuse. Of ethical relevance is that consequences of positive scheduled tests can be unpredictable-in the form of overly severe punishment or a lack of treatment options-and that the scheduled testing paradigm is a poor way to change behaviors. More innovative programs now use a UDT paradigm with more frequent, random testing providing rapid results and certain, swift consequences and addiction treatment when warranted or requested. Studies have shown these new programs-the foundation of which is frequent, random UDTs-to significantly reduce drug use, criminal recidivism, and incarceration. © 2017 American Medical Association. All Rights Reserved.

  6. Corrosion behavior of environmental assessment glass in product consistency tests of extended duration

    International Nuclear Information System (INIS)

    Bates, J.K.; Buck, E.C.; Ebert, W.L.; Luo, J.S.; Tam, S.W.

    1998-01-01

    We have conducted static dissolution tests to study the corrosion behavior of the Environmental Assessment (EA) glass, which is the benchmark glass for high-level waste glasses being produced at US Department of Energy facilities. These tests were conducted to evaluate the behavior of the EA glass under the same long-term and accelerated test conditions that are being used to evaluate the corrosion of waste glasses. Tests were conducted at 90 C in a tuff groundwater solution at glass surface area/solution volume (WV) ratios of about 2000 and 20,000 m -1 . The glass dissolved at three distinct dissolution rates in tests conducted at 2000 m -1 . Based on the release of boron, dissolution within the first seven days occurred at a rate of about 0.65 g/(m 2 · d). The rate between seven and 70 days decreased to 0.009 g/(m 2 · d). An increase in the dissolution rate occurred at longer times after the precipitation of zeolite phases analcime, gmelinite, and an aluminum silicate base. The dissolution rate after phase formation was about 0.18 g/(m 2 · d). The formation of the same zeolite alteration phases occurred after about 20 days in tests at 20,000 m - . The average dissolution rate over the first 20 days was 0.5 g/(m 2 · d) and the rate after phase formation was about 0.20 g/(m 2 · d). An intermediate stage with a lower rate was not observed in tests at 20,000 m -1 . The corrosion behavior of EA glass is similar to that observed for other high-level waste glasses reacted under the same test conditions. The dissolution rate of EA glass is higher than that of other high-level waste glasses both in 7-day tests and after alteration phases form

  7. A Timoshenko Piezoelectric Beam Finite Element with Consistent Performance Irrespective of Geometric and Material Configurations

    Directory of Open Access Journals (Sweden)

    Litesh N. Sulbhewar

    Full Text Available Abstract The conventional Timoshenko piezoelectric beam finite elements based on First-order Shear Deformation Theory (FSDT do not maintain the accuracy and convergence consistently over the applicable range of material and geometric properties. In these elements, the inaccuracy arises due to the induced potential effects in the transverse direction and inefficiency arises due to the use of independently assumed linear polynomial interpolation of the field variables in the longitudinal direction. In this work, a novel FSDT-based piezoelectric beam finite element is proposed which is devoid of these deficiencies. A variational formulation with consistent through-thickness potential is developed. The governing equilibrium equations are used to derive the coupled field relations. These relations are used to develop a polynomial interpolation scheme which properly accommodates the bending-extension, bending-shear and induced potential couplings to produce accurate results in an efficient manner. It is noteworthy that this consistently accurate and efficient beam finite element uses the same nodal variables as of conventional FSDT formulations available in the literature. Comparison of numerical results proves the consistent accuracy and efficiency of the proposed formulation irrespective of geometric and material configurations, unlike the conventional formulations.

  8. Road Service Performance Based On Integrated Road Design Consistency (IC Along Federal Road F0023

    Directory of Open Access Journals (Sweden)

    Zainal Zaffan Farhana

    2017-01-01

    Full Text Available Road accidents are one of the world’s largest public health and injury prevention problems. In Malaysia, the west coast area of Malaysia been stated as the highest motorcycle fatalities and road accidents are one of the factors that cause of death and injuries in this country. The most common fatal accident is between a motorcycle and passenger car. The most of the fatal accidents happened on Federal roads with 44 fatal accidents reported, which is equal to 29%. Lacks of road geometric designs consistency where the drivers make mistakes errors due to the road geometric features causes the accident kept rising in Malaysia. Hence, models are based on operating speed to calculate design consistency of road. The profiles were obtained by continuous speed profile using GPS data. The continuous operating speed profile models were plotted based on operating speed model (85th percentile. The study was conduct at F0023 from km 16 until km 20. The purpose of design consistency is to know the relationship between the operating speed and elements of geometric design on the road. As a result, the integrated design consistency motorcycle and cars along a segment at F0023, the threshold shows poor design quality for motorcycles and cars.

  9. Single-field consistency relations of large scale structure part III: test of the equivalence principle

    Energy Technology Data Exchange (ETDEWEB)

    Creminelli, Paolo [Abdus Salam International Centre for Theoretical Physics, Strada Costiera 11, Trieste, 34151 (Italy); Gleyzes, Jérôme; Vernizzi, Filippo [CEA, Institut de Physique Théorique, Gif-sur-Yvette cédex, F-91191 France (France); Hui, Lam [Physics Department and Institute for Strings, Cosmology and Astroparticle Physics, Columbia University, New York, NY, 10027 (United States); Simonović, Marko, E-mail: creminel@ictp.it, E-mail: jerome.gleyzes@cea.fr, E-mail: lhui@astro.columbia.edu, E-mail: msimonov@sissa.it, E-mail: filippo.vernizzi@cea.fr [SISSA, via Bonomea 265, Trieste, 34136 (Italy)

    2014-06-01

    The recently derived consistency relations for Large Scale Structure do not hold if the Equivalence Principle (EP) is violated. We show it explicitly in a toy model with two fluids, one of which is coupled to a fifth force. We explore the constraints that galaxy surveys can set on EP violation looking at the squeezed limit of the 3-point function involving two populations of objects. We find that one can explore EP violations of order 10{sup −3}÷10{sup −4} on cosmological scales. Chameleon models are already very constrained by the requirement of screening within the Solar System and only a very tiny region of the parameter space can be explored with this method. We show that no violation of the consistency relations is expected in Galileon models.

  10. Are estimates of meaningful decline in mobility performance consistent among clinically important subgroups? (Health ABC Study).

    NARCIS (Netherlands)

    Perera, S.; Studenski, S.; Newman, A.; Simonsick, E.; Harris, T.; Schwartz, A.; Visser, M.

    2014-01-01

    Background: Meaningful change criteria help determine if function has improved or declined, but their magnitudes may vary across clinically relevant subgroups. We estimate meaningful decline in four common measures of physical performance in subgroups of older adults based on initial performance,

  11. Air Force Officials did not Consistently Comply with Requirements for Assessing Contractor Performance

    Science.gov (United States)

    2016-01-29

    31 Appendix B. Improvement in PAR Completion Statistics _________________________________ 33 vi...agencies must perform frequent evaluation of compliance with reporting requirements so they can readily identify delinquent past performance efforts...Reporting Program,” August 13, 2011 Appendixes DODIG-2016-043 │ 33 Appendix B Improvement in PAR Completion Statistics The Senate Armed Services Committee

  12. Consistency of Pilot Trainee Cognitive Ability, Personality, and Training Performance in Undergraduate Pilot Training

    Science.gov (United States)

    2013-09-09

    multivariate correction method (Lawley, 1943) was used for all scores except the MAB FSIQ which used the univariate ( Thorndike , 1949) method. FSIQ... Thorndike , R. L. (1949). Personnel selection. NY: Wiley. Tupes, E. C., & Christal, R. C. (1961). Recurrent personality factors based on trait ratings... Thorndike , 1949). aThe correlations for 1995 were not corrected due to the small sample size (N = 17). *p< .05 Consistency of Pilot Attributes

  13. Validity test and its consistency in the construction of patient loyalty model

    Science.gov (United States)

    Yanuar, Ferra

    2016-04-01

    The main objective of this present study is to demonstrate the estimation of validity values and its consistency based on structural equation model. The method of estimation was then implemented to an empirical data in case of the construction the patient loyalty model. In the hypothesis model, service quality, patient satisfaction and patient loyalty were determined simultaneously, each factor were measured by any indicator variables. The respondents involved in this study were the patients who ever got healthcare at Puskesmas in Padang, West Sumatera. All 394 respondents who had complete information were included in the analysis. This study found that each construct; service quality, patient satisfaction and patient loyalty were valid. It means that all hypothesized indicator variables were significant to measure their corresponding latent variable. Service quality is the most measured by tangible, patient satisfaction is the most mesured by satisfied on service and patient loyalty is the most measured by good service quality. Meanwhile in structural equation, this study found that patient loyalty was affected by patient satisfaction positively and directly. Service quality affected patient loyalty indirectly with patient satisfaction as mediator variable between both latent variables. Both structural equations were also valid. This study also proved that validity values which obtained here were also consistence based on simulation study using bootstrap approach.

  14. Consistency of test behaviour and individual difference in prescision of prediction

    NARCIS (Netherlands)

    Meijer, R.R.

    1998-01-01

    Ghiselli ((1956, 1960) argued that the precision of prediction on the basis of a test may vary for different individuals. To quantify the individual precision of prediction he compared the observed criterion scores with the expected criterion scores estimated on the basis of the total scores on a

  15. Individual behavioural differences in pigs: intra- and inter-test consistency

    NARCIS (Netherlands)

    Spoolder, H.A.M.; Burbidge, J.A.; Lawrence, A.B.; Simmins, P.H.

    1996-01-01

    Two studies have been carried out in pigs to determine the relation between escape behaviour and production parameters and between escape behaviour and other factors. In the first, 823 piglets were tested with the backtest at 10 and 17 days of age. Production parameters, such as average daily weight

  16. Integrated Performance Testing Workshop, Modules 6 - 11

    Energy Technology Data Exchange (ETDEWEB)

    Leach, Janice; Torres, Teresa M.

    2012-10-01

    These modules cover performance testing of: Interior Detection Systems; Access Controls; Exterior Detection Systems; Video Assessment Systems; SNM / Contraband Detection Systems; Access Delay Elements

  17. How leader-member exchange, work engagement and HRM consistency explain Chinese luxury hotel employees’ job performance

    NARCIS (Netherlands)

    Li, X.; Sanders, Karin; Frenkel, S.

    2012-01-01

    This paper provides insights into the relationship between leader-member exchange (LMX) and employee job performance. An integrative model that includes work engagement and human resource management (HRM) consistency, defined as the extent to which various HR practices are viewed as consistent with

  18. Consistency of the Relations of Cognitive Ability and Personality Traits to Pilot Training Performance

    Science.gov (United States)

    2014-08-22

    efficient and effective as pos- sible . This article examines the predictive validity of cognitive ability and personality measures for U.S. Air Force...human personality. The domains are Neuroticism (sometimes called emotional stability), Extraversion, Openness, Agreeableness , and Conscientiousness. 250... Agreeableness , and Conscientiousness. In one of the earliest reported studies of the use of personality tests for flying personnel, Sells (1955) showed

  19. Factors associated with not testing for HIV and consistent condom use among men in Soweto, South Africa.

    Directory of Open Access Journals (Sweden)

    Sakhile Mhlongo

    Full Text Available Besides access to medical male circumcision, HIV testing, access to condoms and consistent condom use are additional strategies men can use to prevent HIV acquisition. We examine male behavior toward testing and condom use.To determine factors associated with never testing for HIV and consistent condom use among men who never test in Soweto.A cross-sectional survey in Soweto was conducted in 1539 men aged 18-32 years in 2007. Data were collected on socio-demographic and behavioral characteristics to determine factors associated with not testing and consistent condom use.Over two thirds (71% of men had not had an HIV test and the majority (55%, n = 602 were young (18-23. Of those not testing, condom use was poor (44%, n = 304. Men who were 18-23 years (aOR: 2.261, CI: 1.534-3.331, with primary (aOR: 2.096, CI: 1.058-4.153 or high school (aOR: 1.622, CI: 1.078-2.439 education, had sex in the last 6 months (aOR: 1.703, CI: 1.055-2.751, and had ≥1 sexual partner (aOR: 1.749, CI: 1.196-2.557 were more likely not to test. Of those reporting condom use (n = 1036, 67%, consistent condom use was 43% (n = 451. HIV testing did not correlate with condom use.Low rates of both condom use and HIV testing among men in a high HIV prevalence setting are worrisome and indicate an urgent need to develop innovative behavioral strategies to address this shortfall. Condom use is poor in this population whether tested or not tested for HIV, indicating no association between condom use and HIV testing.

  20. Integration and consistency testing of groundwater flow models with hydro-geochemistry in site investigations in Finland

    International Nuclear Information System (INIS)

    Pitkaenen, P.; Loefman, J.; Korkealaakso, J.; Koskinen, L.; Ruotsalainen, P.; Hautojaervi, A.; Aeikaes, T.

    1999-01-01

    In the assessment of the suitability and safety of a geological repository for radioactive waste the understanding of the fluid flow at a site is essential. In order to build confidence in the assessment of the hydrogeological performance of a site in various conditions, integration of hydrological and hydrogeochemical methods and studies provides the primary method for investigating the evolution that has taken place in the past, and for predicting future conditions at the potential disposal site. A systematic geochemical sampling campaign was started since the beginning of 1990's in the Finnish site investigation programme. This enabled the initiating of integration and evaluation of site scale hydrogeochemical and groundwater flow models. Hydrogeochemical information has been used to screen relevant external processes and variables for definition of the initial and boundary conditions in hydrological simulations. The results obtained from interpretation and modelling hydrogeochemical evolution have been employed in testing the hydrogeochemical consistency of conceptual flow models. Integration and testing of flow models with hydrogeochemical information are considered to improve significantly the hydrogeological understanding of a site and increases confidence in conceptual hydrogeological models. (author)

  1. Defense Organization Officials Did Not Consistently Comply With Requirements for Assessing Contractor Performance

    Science.gov (United States)

    2017-02-01

    must evaluate compliance with reporting requirements frequently so they can readily identify delinquent past performance reports.24 The FAR also...problems the contractor recovered from without impact to the contract/ order. There should have been no significant weaknesses identified. A...contractor had trouble overcoming and state how it impacted the Government. A Marginal rating should be supported by referencing the management tool

  2. Fabrication and performance of pressure-sensing device consisting of electret film and organic semiconductor

    Science.gov (United States)

    Kodzasa, Takehito; Nobeshima, Daiki; Kuribara, Kazunori; Uemura, Sei; Yoshida, Manabu

    2017-04-01

    We propose a new concept of a pressure-sensitive device that consists of an organic electret film and an organic semiconductor. This device exhibits high sensitivity and selectivity against various types of pressure. The sensing mechanism of this device originates from a modulation of the electric conductivity of the organic semiconductor film induced by the interaction between the semiconductor film and the charged electret film placed face to face. It is expected that a complicated sensor array will be fabricated by using a roll-to-roll manufacturing system, because this device can be prepared by an all-printing and simple lamination process without high-level positional adjustment for printing processes. This also shows that this device with a simple structure is suitable for application to a highly flexible device array sheet for an Internet of Things (IoT) or wearable sensing system.

  3. Performance test for a solar water heater

    Science.gov (United States)

    1979-01-01

    Two reports describe procedures and results of performance tests on domestic solar powered hot water system. Performance tests determine amount of energy collected by system, amount of energy delivered to solar source, power required to operate system and maintain proper tank temperature, overall system efficiency, and temperature distribution in tank.

  4. Performance Testing of Download Services of COSMC

    Directory of Open Access Journals (Sweden)

    Jiří Horák

    2013-11-01

    Full Text Available The paper presents results of performance tests of download services of Czech Office of Surveying, Mapping and Cadastre according to INSPIRE  requirements. Methodology of testing is explained, including monitoring performance  of reference servers. 26 millions of random requests were generated for each monitored operation, layer and coordinate system. The temporal development of performance indicators are analyzed and discussed. Results of performance tests approve the compliance with INSPIRE qualitative requirements for download services. All monitored services satisfy requirements of latency, capacity and availability. The latency and availability requirements are fulfilled with an abundant reserve. No problems in structure and content of responses were detected.

  5. Operational quality control of daily precipitation using spatio-climatological consistency testing

    Science.gov (United States)

    Scherrer, S. C.; Croci-Maspoli, M.; van Geijtenbeek, D.; Naguel, C.; Appenzeller, C.

    2010-09-01

    Quality control (QC) of meteorological data is of utmost importance for climate related decisions. The search for an effective automated QC of precipitation data has proven difficult and many weather services still use mainly manual inspection of daily precipitation including MeteoSwiss. However, man power limitations force many weather services to move towards less labour intensive and more automated QC with the challenge to keeping data quality high. In the last decade, several approaches have been presented to objectify daily precipitation QC. Here we present a spatio-climatological approach that will be implemented operationally at MeteoSwiss. It combines the information from the event based spatial distribution of everyday's precipitation field and the historical information of the interpolation error using different precipitation intensity intervals. Expert judgement shows that the system is able to detect potential outliers very well (hardly any missed errors) without creating too many false alarms that need human inspection. 50-80% of all flagged values have been classified as real errors by the data editor. This is much better than the roughly 15-20% using standard spatial regression tests. Very helpful in the QC process is the automatic redistribution of accumulated several day sums. Manual inspection in operations can be reduced and the QC of precipitation objectified substantially.

  6. Technical Note: Regularization performances with the error consistency method in the case of retrieved atmospheric profiles

    Directory of Open Access Journals (Sweden)

    S. Ceccherini

    2007-01-01

    Full Text Available The retrieval of concentration vertical profiles of atmospheric constituents from spectroscopic measurements is often an ill-conditioned problem and regularization methods are frequently used to improve its stability. Recently a new method, that provides a good compromise between precision and vertical resolution, was proposed to determine analytically the value of the regularization parameter. This method is applied for the first time to real measurements with its implementation in the operational retrieval code of the satellite limb-emission measurements of the MIPAS instrument and its performances are quantitatively analyzed. The adopted regularization improves the stability of the retrieval providing smooth profiles without major degradation of the vertical resolution. In the analyzed measurements the retrieval procedure provides a vertical resolution that, in the troposphere and low stratosphere, is smaller than the vertical field of view of the instrument.

  7. Time and resource limits on working memory: cross-age consistency in counting span performance.

    Science.gov (United States)

    Ransdell, Sarah; Hecht, Steven

    2003-12-01

    This longitudinal study separated resource demand effects from those of retention interval in a counting span task among 100 children tested in grade 2 and again in grades 3 and 4. A last card large counting span condition had an equivalent memory load to a last card small, but the last card large required holding the count over a longer retention interval. In all three waves of assessment, the last card large condition was found to be less accurate than the last card small. A model predicting reading comprehension showed that age was a significant predictor when entered first accounting for 26% of the variance, but counting span accounted for a further 22% of the variance. Span at Wave 1 accounted for significant unique variance at Wave 2 and at Wave 3. Results were similar for math calculation with age accounting for 31% of the variance and counting span accounting for a further 34% of the variance. Span at Wave 1 explained unique variance in math at Wave 2 and at Wave 3.

  8. Corrosion performance tests for reinforcing steel in concrete : test procedures.

    Science.gov (United States)

    2009-09-01

    The existing test method to assess the corrosion performance of reinforcing steel embedded in concrete, mainly : ASTM G109, is labor intensive, time consuming, slow to provide comparative results, and often expensive. : However, corrosion of reinforc...

  9. Vitrification Facility integrated system performance testing report

    International Nuclear Information System (INIS)

    Elliott, D.

    1997-01-01

    This report provides a summary of component and system performance testing associated with the Vitrification Facility (VF) following construction turnover. The VF at the West Valley Demonstration Project (WVDP) was designed to convert stored radioactive waste into a stable glass form for eventual disposal in a federal repository. Following an initial Functional and Checkout Testing of Systems (FACTS) Program and subsequent conversion of test stand equipment into the final VF, a testing program was executed to demonstrate successful performance of the components, subsystems, and systems that make up the vitrification process. Systems were started up and brought on line as construction was completed, until integrated system operation could be demonstrated to produce borosilicate glass using nonradioactive waste simulant. Integrated system testing and operation culminated with a successful Operational Readiness Review (ORR) and Department of Energy (DOE) approval to initiate vitrification of high-level waste (HLW) on June 19, 1996. Performance and integrated operational test runs conducted during the test program provided a means for critical examination, observation, and evaluation of the vitrification system. Test data taken for each Test Instruction Procedure (TIP) was used to evaluate component performance against system design and acceptance criteria, while test observations were used to correct, modify, or improve system operation. This process was critical in establishing operating conditions for the entire vitrification process

  10. A general approach to the testing of binary solubility systems for thermodynamic consistency. Consolidated Fuel Reprocessing Program

    Science.gov (United States)

    Hamm, L. L.; Vanbrunt, V.

    1982-08-01

    The numerical solution to the ordinary differential equation which describes the high-pressure vapor-liquid equilibria of a binary system where one of the components is supercritical and exists as a noncondensable gas in the pure state is considered with emphasis on the implicit Runge-Kuta and orthogonal collocation methods. Some preliminary results indicate that the implicit Runge-Kutta method is superior. Due to the extreme nonlinearity of thermodynamic properties in the region near the critical locus, and extended cubic spline fitting technique is devised for correlating the P-x data. The least-squares criterion is employed in smoothing the experimental data. The technique could easily be applied to any thermodynamic data by changing the endpoint requirements. The volumetric behavior of the systems must be given or predicted in order to perform thermodynamic consistency tests. A general procedure is developed for predicting the volumetric behavior required and some indication as to the expected limit of accuracy is given.

  11. Preferences for HIV test characteristics among young, Black Men Who Have Sex With Men (MSM) and transgender women: Implications for consistent HIV testing

    Science.gov (United States)

    Frye, Victoria; Hirshfield, Sabina; Chiasson, Mary Ann; Lucy, Debbie; Usher, DaShawn; McCrossin, Jermaine; Greene, Emily; Koblin, Beryl

    2018-01-01

    Background Promoting consistent HIV testing is critical among young, Black Men Who Have Sex With Men (MSM) and transgender women who are overrepresented among new HIV cases in the United States. New HIV test options are available, including mobile unit testing, one-minute testing, at home or self-testing and couples HIV testing and counseling (CHTC). In the context of these newer options, the objective of this study was to explore whether and how preferences for specific characteristics of the tests acted as barriers to and/or facilitators of testing in general and consistent testing specifically among young Black MSM and transgender women aged 16 to 29. Methods We conducted 30 qualitative, semi-structured, in-depth interviews with young, Black, gay, bisexual or MSM and transgender women in the New York City metropolitan area to identify preferences for specific HIV tests and aspects of HIV testing options. Participants were primarily recruited from online and mobile sites, followed by community-based, face-to-face recruitment strategies to specifically reach younger participants. Thematic coding was utilized to analyze the qualitative data based on a grounded theoretical approach. Results We identified how past experiences, perceived test characteristics (e.g., accuracy, cost, etc.) and beliefs about the “fit” between the individual, and the test relate to preferred testing methods and consistent testing. Three major themes emerged as important to preferences for HIV testing methods: the perceived accuracy of the test method, venue characteristics, and lack of knowledge or experience with the newer testing options, including self-testing and CHTC. Conclusions These findings suggest that increasing awareness of and access to newer HIV testing options (e.g., free or reduced price on home or self-tests or CHTC available at all testing venues) is critical if these new options are to facilitate increased levels of consistent testing among young, Black MSM and

  12. Preferences for HIV test characteristics among young, Black Men Who Have Sex With Men (MSM) and transgender women: Implications for consistent HIV testing.

    Science.gov (United States)

    Frye, Victoria; Wilton, Leo; Hirshfield, Sabina; Chiasson, Mary Ann; Lucy, Debbie; Usher, DaShawn; McCrossin, Jermaine; Greene, Emily; Koblin, Beryl

    2018-01-01

    Promoting consistent HIV testing is critical among young, Black Men Who Have Sex With Men (MSM) and transgender women who are overrepresented among new HIV cases in the United States. New HIV test options are available, including mobile unit testing, one-minute testing, at home or self-testing and couples HIV testing and counseling (CHTC). In the context of these newer options, the objective of this study was to explore whether and how preferences for specific characteristics of the tests acted as barriers to and/or facilitators of testing in general and consistent testing specifically among young Black MSM and transgender women aged 16 to 29. We conducted 30 qualitative, semi-structured, in-depth interviews with young, Black, gay, bisexual or MSM and transgender women in the New York City metropolitan area to identify preferences for specific HIV tests and aspects of HIV testing options. Participants were primarily recruited from online and mobile sites, followed by community-based, face-to-face recruitment strategies to specifically reach younger participants. Thematic coding was utilized to analyze the qualitative data based on a grounded theoretical approach. We identified how past experiences, perceived test characteristics (e.g., accuracy, cost, etc.) and beliefs about the "fit" between the individual, and the test relate to preferred testing methods and consistent testing. Three major themes emerged as important to preferences for HIV testing methods: the perceived accuracy of the test method, venue characteristics, and lack of knowledge or experience with the newer testing options, including self-testing and CHTC. These findings suggest that increasing awareness of and access to newer HIV testing options (e.g., free or reduced price on home or self-tests or CHTC available at all testing venues) is critical if these new options are to facilitate increased levels of consistent testing among young, Black MSM and transgender women. Addressing perceptions of

  13. Preferences for HIV test characteristics among young, Black Men Who Have Sex With Men (MSM and transgender women: Implications for consistent HIV testing.

    Directory of Open Access Journals (Sweden)

    Victoria Frye

    Full Text Available Promoting consistent HIV testing is critical among young, Black Men Who Have Sex With Men (MSM and transgender women who are overrepresented among new HIV cases in the United States. New HIV test options are available, including mobile unit testing, one-minute testing, at home or self-testing and couples HIV testing and counseling (CHTC. In the context of these newer options, the objective of this study was to explore whether and how preferences for specific characteristics of the tests acted as barriers to and/or facilitators of testing in general and consistent testing specifically among young Black MSM and transgender women aged 16 to 29.We conducted 30 qualitative, semi-structured, in-depth interviews with young, Black, gay, bisexual or MSM and transgender women in the New York City metropolitan area to identify preferences for specific HIV tests and aspects of HIV testing options. Participants were primarily recruited from online and mobile sites, followed by community-based, face-to-face recruitment strategies to specifically reach younger participants. Thematic coding was utilized to analyze the qualitative data based on a grounded theoretical approach.We identified how past experiences, perceived test characteristics (e.g., accuracy, cost, etc. and beliefs about the "fit" between the individual, and the test relate to preferred testing methods and consistent testing. Three major themes emerged as important to preferences for HIV testing methods: the perceived accuracy of the test method, venue characteristics, and lack of knowledge or experience with the newer testing options, including self-testing and CHTC.These findings suggest that increasing awareness of and access to newer HIV testing options (e.g., free or reduced price on home or self-tests or CHTC available at all testing venues is critical if these new options are to facilitate increased levels of consistent testing among young, Black MSM and transgender women. Addressing

  14. Recommended procedures for performance testing of radiobioassay laboratories: Volume 3, In vivo test phantoms

    International Nuclear Information System (INIS)

    MacLellan, J.A.; Traub, R.J.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard describes the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay performance-testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the draft ANSI N13.30 performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of test phantoms used for calibration of measurement systems for direct bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented

  15. The Effects of Humor on Test Anxiety and Test Performance

    Science.gov (United States)

    Tali, Glenda

    2017-01-01

    Testing in an academic setting provokes anxiety in all students in higher education, particularly nursing students. When students experience high levels of anxiety, the resulting decline in test performance often does not represent an accurate assessment of students' academic achievement. This quantitative, experimental study examined the effects…

  16. Integrated Performance Testing for Nonproliferation Support Project

    Energy Technology Data Exchange (ETDEWEB)

    Johns, Russell; Bultz, Garl Alan; Byers, Kenneth R.; Yaegle, William

    2013-08-20

    The objective of this workshop is to provide participants with training in testing techniques and methodologies for assessment of the performance of: Physical Protection system elements; Material Control and Accounting (MC&A) system elements.

  17. Prediction and Cross-Situational Consistency of Daily Behavior across Cultures: Testing Trait and Cultural Psychology Perspectives

    Science.gov (United States)

    Church, A. Timothy; Katigbak, Marcia S.; Reyes, Jose Alberto S.; Salanga, Maria Guadalupe C.; Miramontes, Lilia A.; Adams, Nerissa B.

    2008-01-01

    Trait and cultural psychology perspectives on the cross-situational consistency of behavior, and the predictive validity of traits, were tested in a daily process study in the United States (N = 68), an individualistic culture, and the Philippines (N = 80), a collectivistic culture. Participants completed the Revised NEO Personality Inventory (Costa & McCrae, 1992) and a measure of self-monitoring, then reported their daily behaviors and associated situational contexts for approximately 30 days. Consistent with trait perspectives, the Big Five traits predicted daily behaviors in both cultures, and relative (interindividual) consistency was observed across many, although not all, situational contexts. The frequency of various Big Five behaviors varied across relevant situational contexts in both cultures and, consistent with cultural psychology perspectives, there was a tendency for Filipinos to exhibit greater situational variability than Americans. Self-monitoring showed some ability to account for individual differences in situational variability in the American sample, but not the Filipino sample. PMID:22146866

  18. Summary of functional and performance test procedures

    DEFF Research Database (Denmark)

    Mitzel, Jens; Gülzow, Erich; Friedrich, K. Andreas

    Different Test Modules (TM) are defined for the functional and performance characterization of a PEMFC stack. The master document TM2.00 defines requirements and methodology for parameter variation, stability and data acquisition.......Different Test Modules (TM) are defined for the functional and performance characterization of a PEMFC stack. The master document TM2.00 defines requirements and methodology for parameter variation, stability and data acquisition....

  19. Severe fuel-damage scoping test performance

    International Nuclear Information System (INIS)

    Gruen, G.E.; Buescher, B.J.

    1983-01-01

    As a result of the Three Mile Island Unit-2 (TMI-2) accident, the Nuclear Regulatory Commission has initiated a severe fuel damage test program to evaluate fuel rod and core response during severe accidents similar to TMI-2. The first test of Phase I of this series has been successfully completed in the Power Burst Facility at the Idaho National Engineering Laboratory. Following the first test, calculations were performed using the TRAC-BD1 computer code with actual experimental boundary conditions. This paper discusses the test conduct and performance and presents the calculated and measured test bundle results. The test resulted in a slow heatup to 2000 K over about 4 h, with an accelerated reaction of the zirconium cladding at temperatures above 1600 K in the lower part or the bundle and 2000 K in the upper portion of the bundle

  20. Work zone performance measures pilot test.

    Science.gov (United States)

    2011-04-01

    Currently, a well-defined and validated set of metrics to use in monitoring work zone performance do not : exist. This pilot test was conducted to assist state DOTs in identifying what work zone performance : measures can and should be targeted, what...

  1. RHIC sextant test: Accelerator systems and performance

    Energy Technology Data Exchange (ETDEWEB)

    Pilat, F.; Trbojevic, D.; Ahrens, L. [and others

    1997-08-01

    One sextant of the RHIC Collider was commissioned in early 1997 with beam. We describe here the performance of the accelerator systems, instrumentation subsystems and application software. We also describe a ramping test without beam that took place after the commissioning with beam. Finally, we analyze the implications of accelerator systems performance and their impact on the planning for RHIC installation and commissioning.

  2. RHIC sextant test: Accelerator systems and performance

    International Nuclear Information System (INIS)

    Pilat, F.; Trbojevic, D.; Ahrens, L.

    1997-01-01

    One sextant of the RHIC Collider was commissioned in early 1997 with beam. We describe here the performance of the accelerator systems, instrumentation subsystems and application software. We also describe a ramping test without beam that took place after the commissioning with beam. Finally, we analyze the implications of accelerator systems performance and their impact on the planning for RHIC installation and commissioning

  3. The influence of shyness on children's test performance.

    Science.gov (United States)

    Crozier, W Ray; Hostettler, Kirsten

    2003-09-01

    Research has shown that shy children differ from their peers not only in their use of language in routine social encounters but also in formal assessments of their language development, including psychometric tests of vocabulary. There has been little examination of factors contributing to these individual differences. To investigate cognitive-competence and social anxiety interpretations of differences in children's performance on tests of vocabulary. To examine the performance of shy and less shy children under different conditions of test administration, individually with an examiner or among their peers within the familiar classroom setting. The sample consisted of 240 Year 5 pupils (122 male, 118 female) from 24 primary schools. Shy and less shy children, identified by teacher nomination and checklist ratings, completed vocabulary and mental arithmetic tests in one of three conditions, in a between-subjects design. The conditions varied individual and group administration, and oral and written responses. The conditions of test administration influenced the vocabulary test performance of shy children. They performed significantly more poorly than their peers in the two face-to-face conditions but not in the group test condition. A comparable trend for the arithmetic test was not statistically significant. Across the sample as a whole, shyness correlated significantly with test scores. Shyness does influence children's cognitive test performance and its impact is larger when children are tested face-to-face rather than in a more anonymous group setting. The results are of significance for theories of shyness and have implications for the assessment of schoolchildren.

  4. Performance of smokeless gasoline fire test facility

    International Nuclear Information System (INIS)

    Griffin, J.F.; Watkins, R.A.

    1978-01-01

    Packaging for radioactive materials must perform satisfactorily when subjected to temperatures simulating an accident involving a fire. The new thermal test facility has proved to be a reliable method for satisfactorily performing the required test. The flame provides sufficient heat to assure that the test is valid, and the temperature can be controlled satisfactorily. Also, the air and water mist systems virtually eliminate any smoke and thereby exceed the local EPA requirements. The combination of the two systems provides an inexpensive, low maintenance technique for elimination of the smoke plume

  5. On the (in)consistency of citizen and municipal level indicators of social capital and local government performance

    NARCIS (Netherlands)

    Kampen, J.K.

    2010-01-01

    We study the empirical consistency of survey based (micro level) indicators of social capital and local government performance on the one, and municipality based (aggregate level) measures of these two concepts on the other hand. Knowledge about the behavior of these indicators is helpful for

  6. Should we assess clinical performance in single patient encounters or consistent behaviors of clinical performance over a series of encounters? A qualitative exploration of narrative trainee profiles

    NARCIS (Netherlands)

    Oerlemans, M.; Dielissen, P.W.; Timmerman, A.; Ram, P.; Maiburg, B.; Muris, J.; Vleuten, C. van der

    2017-01-01

    BACKGROUND: A variety of tools have been developed to assess performance which typically use a single clinical encounter as a source for making competency inferences. This strategy may miss consistent behaviors. We therefore explored experienced clinical supervisors' perceptions of behavioral

  7. Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test

    International Nuclear Information System (INIS)

    Bae, Kyoo Whan; Song, Jin Ho; Chung, Young Jong; Sim, Suk Ku; Park, Jong Kyun

    1999-03-01

    The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring in the downcomer with limited budget and time, the separate effects test focusing on this region is considered to be effective and the conceptual test facility based on this recommended. For this test facility the test initial and boundary conditions are developed using the CEFLASH-4AS/REM analysis results that will be used as input for the preliminary test requirements. The final test requirements will be developed through the further discussions with the test performance group. (Author). 10 refs., 18 tabs., 4 figs

  8. DEVELOPING an ENGLISH PERFORMANCE TEST for INCOMING INDONESIAN COLLEGE STUDENTS

    Directory of Open Access Journals (Sweden)

    Bill Glenny Wullur

    2011-07-01

    that the two tests are highly correlated at .964 using gamma test.  (4 The construct validation was conducted in two ways: item analysis for objective section of the test, and Rasch Analysis for subjective section.  The item analysis found that only three items are “fair”, while the remaining are either “good” or “very good”.  Rasch Analysis found that the raters could interpret the rating system and that the test is well fit and accurate.  In general, the proposed performance test is valid. The reliability of the test was established using the internal consistency index.  The findings revealed that all sections of the test are highly consistent at Kendall’s Coefficient of Concordance of .927.  The correlation between sections to overall scores was also calculated, and found that each section is highly correlated at.942 (Formal Letter, .934 (Application Form, .917 (Making Appointment and .862 (Oral Presentation using Kendall’s tau-b test. The practicality of the test was established by analyzing the percentage distribution of score of the pilot tests and field test.  The findings showed that the scores are well distributed in all four levels, and a pattern of distribution exists at Spearman’s ρ .85 correlation coefficient.  Therefore, the rating system is found practical and predictive. The output of the study is a resultant and valid English Performance Test for Incoming Indonesian College Students.  The test is named:  Academic English Performance Test or ACCEPT.

  9. Expanding the Reach of Participatory Risk Management: Testing an Online Decision-Aiding Framework for Informing Internally Consistent Choices.

    Science.gov (United States)

    Bessette, Douglas L; Campbell-Arvai, Victoria; Arvai, Joseph

    2016-05-01

    This article presents research aimed at developing and testing an online, multistakeholder decision-aiding framework for informing multiattribute risk management choices associated with energy development and climate change. The framework was designed to provide necessary background information and facilitate internally consistent choices, or choices that are in line with users' prioritized objectives. In order to test different components of the decision-aiding framework, a six-part, 2 × 2 × 2 factorial experiment was conducted, yielding eight treatment scenarios. The three factors included: (1) whether or not users could construct their own alternatives; (2) the level of detail regarding the composition of alternatives users would evaluate; and (3) the way in which a final choice between users' own constructed (or highest-ranked) portfolio and an internally consistent portfolio was presented. Participants' self-reports revealed the framework was easy to use and providing an opportunity to develop one's own risk-management alternatives (Factor 1) led to the highest knowledge gains. Empirical measures showed the internal consistency of users' decisions across all treatments to be lower than expected and confirmed that providing information about alternatives' composition (Factor 2) resulted in the least internally consistent choices. At the same time, those users who did not develop their own alternatives and were not shown detailed information about the composition of alternatives believed their choices to be the most internally consistent. These results raise concerns about how the amount of information provided and the ability to construct alternatives may inversely affect users' real and perceived internal consistency. © 2015 Society for Risk Analysis.

  10. VLE measurements using a static cell vapor phase manual sampling method accompanied with an empirical data consistency test

    International Nuclear Information System (INIS)

    Freitag, Joerg; Kosuge, Hitoshi; Schmelzer, Juergen P.; Kato, Satoru

    2015-01-01

    Highlights: • We use a new, simple static cell vapor phase manual sampling method (SCVMS) for VLE (x, y, T) measurement. • The method is applied to non-azeotropic, asymmetric and two-liquid phase forming azeotropic binaries. • The method is approved by a data consistency test, i.e., a plot of the polarity exclusion factor vs. pressure. • The consistency test reveals that with the new SCVMS method accurate VLE near ambient temperature can be measured. • Moreover, the consistency test approves that the effect of air in the SCVMS system is negligible. - Abstract: A new static cell vapor phase manual sampling (SCVMS) method is used for the simple measurement of constant temperature x, y (vapor + liquid) equilibria (VLE). The method was applied to the VLE measurements of the (methanol + water) binary at T/K = (283.2, 298.2, 308.2 and 322.9), asymmetric (acetone + 1-butanol) binary at T/K = (283.2, 295.2, 308.2 and 324.2) and two-liquid phase forming azeotropic (water + 1-butanol) binary at T/K = (283.2 and 298.2). The accuracy of the experimental data was approved by a data consistency test, that is, an empirical plot of the polarity exclusion factor, β, vs. the system pressure, P. The SCVMS data are accurate, because the VLE data converge to the same lnβ vs. lnP straight line determined from conventional distillation-still method and a headspace gas chromatography method

  11. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  12. Development of turbopump cavitation performance test facility and the test of inducer performance

    International Nuclear Information System (INIS)

    Sohn, Dong Kee; Kim, Chun Tak; Yoon, Min Soo; Cha, Bong Jun; Kim, Jin Han; Yang, Soo Seok

    2001-01-01

    A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar, rotational speed - 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification

  13. Frequency and determinants of consistent STI/HIV testing among men who have sex with men testing at STI outpatient clinics in the Netherlands: a longitudinal study.

    Science.gov (United States)

    Visser, Maartje; Heijne, Janneke C M; Hogewoning, Arjan A; van Aar, Fleur

    2017-09-01

    Men who have sex with men (MSM) are at highest risk for STIs and HIV infections in the Netherlands. However, official guidelines on STI testing among MSM are lacking. They are advised to test for STIs at least every six months, but their testing behaviour is not well known. This study aimed to get insight into the proportion and determinants of consistent 6-monthly STI testing among MSM testing at STI outpatient clinics in the Netherlands. This study included longitudinal surveillance data of STI consultations among MSM from all 26 STI outpatient clinics in the Netherlands between 1 June 2014 and 31 December 2015. Multinomial logistic regression analysis was used to identify determinants of consistent 6-monthly testing compared with single testing and inconsistent testing. Determinants of time between consultations among men with multiple consultations were analysed using a Cox Prentice-Williams-Peterson gap-time model. A total of 34 605 STI consultations of 18 634 MSM were included. 8966 (48.1%) men had more than one consultation, and 3516 (18.9%) men tested consistently 6-monthly. Indicators of high sexual risk behaviour, including having a history of STI, being HIV positive and having more than 10 sex partners, were positively associated with both being a consistent tester and returning to the STI clinic sooner. Men who were notified by a partner or who reported STI symptoms were also more likely to return to the STI clinic sooner, but were less likely to be consistent testers, identifying a group of event-driven testers. The proportion of consistent 6-monthly testers among MSM visiting Dutch STI outpatient clinics was low. Testing behaviour was associated with sexual risk behaviour, but exact motives to test consistently remain unclear. Evidence-based testing guidelines are needed to achieve optimal reductions in STI transmission in the future. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence

  14. Stereotype threat? Effects of inquiring about test takers' gender on conceptual test performance in physics

    Science.gov (United States)

    Maries, Alexandru; Singh, Chandralekha

    2015-12-01

    It has been found that activation of a stereotype, for example by indicating one's gender before a test, typically alters performance in a way consistent with the stereotype, an effect called "stereotype threat." On a standardized conceptual physics assessment, we found that asking test takers to indicate their gender right before taking the test did not deteriorate performance compared to an equivalent group who did not provide gender information. Although a statistically significant gender gap was present on the standardized test whether or not students indicated their gender, no gender gap was observed on the multiple-choice final exam students took, which included both quantitative and conceptual questions on similar topics.

  15. Testing prospect theory in students’ performance

    OpenAIRE

    Pérez Galdón, Patricia; Nicolau, Juan Luis

    2013-01-01

    This paper tests the existence of ‘reference dependence’ and ‘loss aversion’ in students’ academic performance. Accordingly, achieving a worse than expected academic performance would have a much stronger effect on students’ (dis)satisfaction than obtaining a better than expected grade. Although loss aversion is a well-established finding, some authors have demonstrated that it can be moderated – diminished, to be precise–. Within this line of research, we also examine whether the students’ e...

  16. Fast Flux Test Facility core restraint system performance

    International Nuclear Information System (INIS)

    Hecht, S.L.; Trenchard, R.G.

    1990-02-01

    Characterizing Fast Flux Test Facility (FFTF) core restraint system performance has been ongoing since the first operating cycle. Characterization consists of prerun analysis for each core load, in-reactor and postirradiation measurements of subassembly withdrawal loads and deformations, and using measurement data to fine tune predictive models. Monitoring FFTF operations and performing trend analysis has made it possible to gain insight into core restraint system performance and head off refueling difficulties while maximizing component lifetimes. Additionally, valuable information for improved designs and operating methods has been obtained. Focus is on past operating experience, emphasizing performance improvements and avoidance of potential problems. 4 refs., 12 figs., 2 tabs

  17. Test-Retest Reliability, Convergent Validity, and Internal Consistency of the Persian Version of Fullerton Advanced Balance Scale in Iranian Community-Dwelling Older Adults

    OpenAIRE

    Azar Sabet; Akram Azad; Ghorban Taghizadeh

    2016-01-01

    Objectives: This study was performed to evaluate convergent validity, test-retest reliability and internal consistency of the Persian translation of the Fullerton advanced balance (FAB) for use in Iranian community- dwelling older adults and improve the quality of their functional balance assessment. Methods & Materials: The original scale was translated with forward-backward protocol. In the next step, using convenience sampling and inclusion criteria, 88 functionally indep...

  18. NetBench. Automated Network Performance Testing

    CERN Document Server

    Cadeddu, Mattia

    2016-01-01

    In order to evaluate the operation of high performance routers, CERN has developed the NetBench software to run benchmarking tests by injecting various traffic patterns and observing the network devices behaviour in real-time. The tool features a modular design with a Python based console used to inject traffic and collect the results in a database, and a web user

  19. Testing for Distortions in Performance Measures

    DEFF Research Database (Denmark)

    Sloof, Randolph; Van Praag, Mirjam

    2015-01-01

    Distorted performance measures in compensation contracts elicit suboptimal behavioral responses that may even prove to be dysfunctional (gaming). This paper applies the empirical test developed by Courty and Marschke (Review of Economics and Statistics, 90, 428-441) to detect whether the widely...

  20. Testing for Distortions in Performance Measures

    DEFF Research Database (Denmark)

    Sloof, Randolph; Van Praag, Mirjam

    Distorted performance measures in compensation contracts elicit suboptimal behavioral responses that may even prove to be dysfunctional (gaming). This paper applies the empirical test developed by Courty and Marschke (2008) to detect whether the widely used class of Residual Income based performa...

  1. Drop Performance Test of CRDMs for JRTR

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Myoung-Hwan; Cho, Yeong-Garp; Chung, Jong-Ha [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Jung-Hyun [POSCO Plandtec Co. Ltd, Ulsan (Korea, Republic of); Lee, Kwan-Hee [RIST, Pohang (Korea, Republic of)

    2015-10-15

    The drop test results of CRDMs with AC-type electromagnet show that the initial delay times are not satisfied with the requirement, 0.15 seconds. After the replacement of the electromagnet from AC-type to DCtype, the drop times of CARs and accelerations due to the impact of moving parts are satisfied with all requirements. As a result, it is found that four CRDMs to be installed at site have a good drop performance, and meet all performance requirements. A control rod drive mechanism (CRDM) is a device to control the position of a control absorber rod (CAR) in the core by using a stepping motor which is commanded by the reactor regulating system (RRS) to control the reactivity during the normal operation of the reactor. The top-mounted CRDM driven by the stepping motor for Jordan Research and Training Reactor (JRTR) has been developed in KAERI. The CRDM for JRTR has been optimized by the design improvement based on that of the HANARO. It is necessary to verify the performances such as the stepping, drop, endurance, vibration, seismic and structural integrity for active components. Especially, the CAR drop curves are important data for the safety analysis. This paper describes the test results to demonstrate the drop performances of a prototype and 4 CRDMs to be installed at site. The tests are carried out at a test rig simulating the actual reactor's conditions.

  2. SIMS Prototype System 4: performance test report

    Energy Technology Data Exchange (ETDEWEB)

    1978-10-09

    The results obtained during testing of a self-contained, preassembled air type solar system, designed for installation remote from the dwelling, to provide space heating and hot water are presented. Data analysis is included which documents the system performance and verifies the suitability of SIMS Prototype System 4 for field installation.

  3. Performance tests for integral reactor nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Dong-Seong; Yim, Jeong-Sik; Lee, Chong-Tak; Kim, Han-Soo; Koo, Yang-Hyun; Lee, Byung-Ho; Cheon, Jin-Sik; Oh, Je-Yong

    2006-02-15

    An integral type reactor SMART plans to utilize metallic Zr-U fuel which is Zr-based alloy with 34{approx}38 wt% U. In order to verify the technologies for the design and manufacturing of the fuel and get a license, performance tests were carried out. Experimental Fuel Assembly (EFA) manufactured in KAERI is being successfully irradiated in the MIR reactor of RIAR from September 4 2004, and it has achieved burnup of 0.21 g/cc as of January 25 2006. Thermal properties of irradiated Zr-U fuel were measured. Up to the phase transformation temperature, thermal diffusivity increased linearly in proportion to temperature. However its dependence on the burnup was not significant. RIA tests with 4 unirradiated Zr-U fuel rods were performed in Kurchatov Institute to establish a safety criterion. In the case of the un-irradiated Zr-U fuel, the energy deposition during the control rod ejection accident should be less than 172 cal/g to prevent the failure accompanying fuel fragmentation and dispersal. Finally the irradiation tests of fuel rods have been performed at HANARO. The HITE-2 test was successfully completed up to a burnup of 0.31 g/cc. The HITE-3 test began in February 2004 and will be continued up to a target burnup of 0.6 g/cc.

  4. Motivation and Test Anxiety in Test Performance across Three Testing Contexts: The CAEL, CET, and GEPT

    Science.gov (United States)

    Cheng, Liying; Klinger, Don; Fox, Janna; Doe, Christine; Jin, Yan; Wu, Jessica

    2014-01-01

    This study examined test-takers' motivation, test anxiety, and test performance across a range of social and educational contexts in three high-stakes language tests: the Canadian Academic English Language (CAEL) Assessment in Canada, the College English Test (CET) in the People's Republic of China, and the General English Proficiency Test (GEPT)…

  5. MFTF test coil construction and performance

    International Nuclear Information System (INIS)

    Cornish, D.N.; Zbasnik, J.P.; Leber, R.L.; Hirzel, D.G.; Johnston, J.E.; Rosdahl, A.R.

    1978-01-01

    A solenoid coil, 105 cm inside the 167 cm outside diameter, has been constructed and tested to study the performance of the stabilized Nb--Ti conductor to be used in the Mirror Fusion Test Facility (MFTF) being built at Lawrence Livermore Laboratory. The insulation system of the test coil is identical to that envisioned for MFTF. Cold-weld joints were made in the conductor at the start and finish of each layer; heaters were fitted to some of these joints and also to the conductor at various locations in the winding. This paper gives details of the construction of the coil and the results of the tests carried out to determine its propagation and recovery characteristics

  6. Assessment of test-retest reliability and internal consistency of the Wisconsin Gait Scale in hemiparetic post-stroke patients

    Directory of Open Access Journals (Sweden)

    Guzik Agnieszka

    2016-09-01

    Full Text Available Introduction: A proper assessment of gait pattern is a significant aspect in planning the process of teaching gait in hemiparetic post-stroke patients. The Wisconsin Gait Scale (WGS is an observational tool for assessing post-stroke patients’ gait. The aim of the study was to assess test-retest reliability and internal consistency of the WGS and examine correlations between gait assessment made with the WGS and gait speed, Brunnström scale, Ashworth’s scale and the Barthel Index.

  7. Performance Test of CCTV in a Test Field

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyung Min [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2011-10-15

    On April 12-13, 2010, US President Obama hosted a Nuclear Security Summit in Washington, DC, to enhance international cooperation to prevent nuclear terrorism, an issue which he has identified as the most immediate and extreme threat to global security. The Summit focused on the security of nuclear materials, nonproliferation, disarmament, and peaceful nuclear energy. At the summit, the Republic of Korea was chosen as the host of the next Summit in 2012. This series of events reflects the growing global interest on 'Nuclear Security' and as the host country of the next Nuclear Summit it is the time for Korea to strengthen the physical protection regime for nuclear facilities as a first step of securing its nuclear security capability. KINAC has been operating Test field as a mean of preparing solid backup data for reviewing and revising DBT (Design Basis Threat) and to test components of the conventional physical protection system. CCTV is a key component which is used worldwide for the assessment measure of alarms. In terms of performance test of CCTV, there are several elements such as image quality, coverage and mechanical features (speed of zoom-in-out, capture, angle shift etc.). Speaking of image quality acquired by the CCTV, the quality is subject to resolution, monitor specification, camera housing, camera mounting and lightening. Thus it is clear that performance tests on image quality should consider those factors and vary the factors respectively in order to verify the influence and the interaction among those. Nevertheless due to the restrictions of the current Test field, this paper focuses on the image quality through resolution test under the various lightening conditions

  8. Full-scale locomotive dynamic crash testing and correlations : locomotive consist colliding with steel coil truck at grade crossing (test 3).

    Science.gov (United States)

    2011-09-01

    This report presents the test results and finite element correlations of a full-scale dynamic collision between a locomotive and a highway truck loaded with two heavy steel coils. The locomotive consist was moving at 58 miles per hour before it struc...

  9. Eurados trial performance test for photon dosimetry

    DEFF Research Database (Denmark)

    Stadtmann, H.; Bordy, J.M.; Ambrosi, P.

    2001-01-01

    Within the framework of the EURADOS Action entitled Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation, trial performance tests for whole-body and extremity personal dosemeters were carried out. Photon, beta and neutron dosemeters were considered....... This paper summarises the results of the whole-body photon dosemeter test. Twenty-six dosimetry services from all EU Member States and Switzerland participated. Twelve different radiation fields were used to simulate various workplace irradiation fields. Dose values from 0.4 mSv to 80 mSv were chosen. From...

  10. Testing Solutions for Adult Film Performers.

    Science.gov (United States)

    Bergman, Zachary R

    2014-01-01

    The majority of the nation's adult films are produced in California, and within California, most production occurs in Los Angeles. In order to regulate that content, the County of Los Angeles passed the Safer Sex in the Adult Film Industry Act (Measure B) by way of referendum in November 2012. Measure B requires that adult film producers wishing to film in Los Angeles County obtain permits from the Los Angeles County Department of Public Health, and it also mandates that adult film performers use condoms while filming and "engaging in anal or vaginal sexual intercourse." Nevertheless, between August 2013 and January 2014, several adult film performers in California tested positive for HIV, and the threat of infection remains. Although Measure B is not the best way forward for Los Angeles County, elements of the ordinance should be incorporated into future legislative efforts. Given the economic ramifications of industry flight due to more localized regulations, this Note concludes that California should pass statewide comprehensive reform. Any such new legislation must treat "independent contractors," the classification generally used for adult film performs, as if they were regular employees. Legislation should also couple mandatory testing mechanisms with provisions granting performers the right to choose whether they use condoms. Finally, legislation must include mechanisms that ensure performers' preferences are not improperly tainted by outside forces and pressures. While there will always be risks associated with the production of adult content, if undertaken, these reforms could significantly mitigate those hazards.

  11. Motivation and performance in physical education: an experimental test.

    Science.gov (United States)

    Moreno, Juan A; González-Cutre, David; Martín-Albo, José; Cervelló, Eduardo

    2010-01-01

    The purpose of this study was to analyse, experimentally, the relationships between motivation and performance in a lateral movement test in physical education. The study group consisted of 363 students (227 boys and 136 girls), aged between 12 and 16, who were randomly divided into three groups: an experimental group in which an incremental ability belief was induced, another experimental group in which an entity ability belief was induced, and a control group where there was no intervention. Measurements were made of situational intrinsic motivation, perceived competence in executing the task and performance. The results revealed that the incremental group reported higher scores on the situational intrinsic motivation scale. The entity group demonstrated better performance in the first test attempt than the incremental group but, in the second attempt, the performance was similar in the different groups. Perhaps the initial differences in performance disappeared because the incremental group counted on improving in the second attempt. These results are discussed in relation to the intensity with which the teacher conveys information relating to incremental ability belief of the pupil to increase intrinsic motivation and performance. Key pointsThe incremental group showed more situational intrinsic motivation.The entity group showed higher performance in the first test attempt, but significant differences disappeared in the second attempt.It seems that this incremental belief and greater intrinsic motivation made the students trust they would improve their performance in the second attempt at the lateral movement test.

  12. Performance test of 100 W linear compressor

    Energy Technology Data Exchange (ETDEWEB)

    Ko, J; Ko, D. Y.; Park, S. J.; Kim, H. B.; Hong, Y. J.; Yeom, H. K. [Korea Institute of Machinery and Materials, Daejeon(Korea, Republic of)

    2013-09-15

    In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.

  13. Performance test of a TMS calorimeter

    International Nuclear Information System (INIS)

    Wild, B.

    1986-10-01

    Performance tests of a first calorimeter module using the room temperature liquid tetramethylsilane (TMS) as active element are described in detail. As absorber planed carbon steel slabs had been used. The charge yield is 70% of that in a very pure sample of the liquid. A long term stability of the signal with a lifetime of half a year has been realized. Experiences are described and the results explained in detail. (orig.) [de

  14. RHIC Sextant Test -- Physics and performance

    International Nuclear Information System (INIS)

    Wei, J.; Fischer, W.; Ahrens, L.

    1997-01-01

    This paper presents beam physics and machine performance results of the Relativistic Heavy Ion Collider (RHIC) Sextant and AGS-to-RHIC (AtR) transfer line during the Sextant Test in early 1997. Techniques used to measure both machine properties (difference orbits, dispersion, and beamline optics) and beam parameters (energy, intensity, transverse and longitudinal emittances) are described. Good agreement was achieved between measured and design lattice optics. The gold ion beam quality was shown to approach RHIC design requirements

  15. Performance tests on the NRPB thermoluminescent dosemeter

    CERN Document Server

    Shaw, K B

    1977-01-01

    Performance tests on the thermoluminescent dosemeter, designed at NRPB for use in the automated personal dosimetry system, are described. An ultra-thin lithium borate dosemeter has been developed for skin absorbed dose measurement. The X-ray, gamma-ray and beta-ray energy response of the dosemeter has been investigated and the angular response for the dosemeter has been examined. The annealing, read-out and stabilisation procedures for the dosemeter are described.

  16. Investigation of Concrete Electrical Resistivity As a Performance Based Test

    OpenAIRE

    Malakooti, Amir

    2017-01-01

    The purpose of this research project was to identify the extent that concrete resistivity measurements (bulk and/or surface) can be used as a performance based lab test to improve the quality of concrete in Utah bridge decks. By allowing UDOT to specify a required resistivity, concrete bridge deck quality will increase and future maintenance costs will decrease. This research consisted of two phases: the field phase and the lab phase. In the field phase, concrete samples were gathered from...

  17. Heating facility for blanket and performance test

    Energy Technology Data Exchange (ETDEWEB)

    Furuya, Kazuyuki; Kuroda, Toshimasa; Enoeda, Mikio; Sato, Satoshi; Hatano, Toshihisa; Takatsu, Hideyuki; Ohara, Yoshihiro [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Hara, Shigemitsu

    1999-03-01

    A design and a fabrication of heating test facility for a mock-up of the blanket module to be installed in International Thermonuclear Experimental Reactor (ITER) have been conducted to evaluate/demonstrate its heat removal performance and structural soundness under cyclic heat loads. To simulate surface heat flux to the blanket module, infrared heating method is adopted so as to heat large surface area uniformly. The infrared heater is used in vacuum environment (10{sup -4} Torr{approx}), and the lamps are cooled by air flowing through an annulus between the lamp and a cover tube made of quartz glass. Elastomer O rings (available to be used up to {approx}300degC) and used for vacuum seal at outer surface of the cover tube. To prevent excessive heating of the O ring, the end part of the cover tube is specially designed including the tube shape, flow path of air and gold coating on the surface of the cover tube to protect the O ring against thermal radiation from glowing tungsten filament. To examine the performance of the facility, steady state and cyclic operation of the infrared heater were conducted using a small-scaled shielding blanket mock-up as a test specimen. The important results are as follows: (1) Heat flux at the surface of the small-scaled mock-up measured by a calorimeter was {approx}0.2 MW/m{sup 2}. (2) A comparison of thermal analysis results and measured temperature responses showed that the small-scaled mock-up had good heat removal performance. (3) Steady state operation and cyclic operation with step response between the rated and zero powers of the infrared heater were successfully performed, and it was confirmed that this heating facility was well-prepared and available for the thermal cyclic test of a blanket module. (author)

  18. Performance Tests for Bubble Blockage Device

    International Nuclear Information System (INIS)

    Ha, Kwang Soon; Wi, Kyung Jin; Park, Rae Joon; Wan, Han Seong

    2014-01-01

    Postulated severe core damage accidents have a high threat risk for the safety of human health and jeopardize the environment. Versatile measures have been suggested and applied to mitigate severe accidents in nuclear power plants. To improve the thermal margin for the severe accident measures in high-power reactors, engineered corium cooling systems involving boiling-induced two-phase natural circulation have been proposed for decay heat removal. A boiling-induced natural circulation flow is generated in a coolant path between a hot vessel wall and cold coolant reservoir. In general, it is possible for some bubbles to be entrained in the natural circulation loop. If some bubbles entrain in the liquid phase flow passage, flow instability may occur, that is, the natural circulation mass flow rate may be oscillated. A new device to block the entraining bubbles is proposed and verified using air-water test loop. To avoid bubbles entrained in the natural circulation flow loop, a new device was proposed and verified using an air-water test loop. The air injection and liquid circulation loop was prepared, and the tests for the bubble blockage devices were performed by varying the geometry and shape of the devices. The performance of the bubble blockage device was more effective as the area ratio of the inlet to the down-comer increased, and the device height decreased. If the device has a rim to generate a vortex zone, the bubbles will be most effectively blocked

  19. Performance testing SPECT systems: Recent developments

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.

    1985-01-01

    A protocol is used to test as many currently available systems as possible, including both rotating gamma camera systems from GE, Siemens, Toshiba, Technicare, Elscint, Philips, Picker, etc, and single/multi slice system such as the Medimatic. This paper indicates changes that have occurred with respect to preliminary results previously published. Reconstructions were performed in a standard manner, using a Ramp filter and without attenuation correction, in order to reduce the effect of differences in software. The Jaszczak phantom was used to assess overall image quality. Tests were performed using the different collimators available. Image quality improved with better spatial resolution, even at the expense of sensitivity. Non-circular orbits, where available, were tested, and resolution was comparing for various positions and directions. With double headed systems, the results obtained were compared to those using a single head alone. Some gain in image quality seems to have been achieved by better uniformity resulting from improved correction circuitry, by the use of non-circular orbits, and from scatter correction. Potential still exists to improve collimator design

  20. DPM PERFORMANCE TESTING USING RASPBERRY PIS

    CERN Document Server

    Regala, M

    2013-01-01

    This is the final report from attending CERN’s Summer Student Programme. The project goal was to do performance testing on the Disk Pool Manager (DPM), a lightweight, reliable, grid-aware storage software used to store and retrieve data produced by CERN’s LHC experiments using the small, low-end ARM powered devices named Raspberry Pis. The idea behind it was to reason if it’s possible to use a cluster of lower-end, under-capable devices to run DPM, and to conclude if it would be more energy efficient than running it on oversized machines, with the same or comparable performance. If this hypothesis was true, the power-hungry machines could be ditched in favour of these small devices, leading to an enormous saving in overall power consumption and hence, overall cost. In this report, I describe what was the initial project goal and intended outcomes, proceeding to explain the underlying technologies used. Afterwards, I’ll explain the setup used, the tests performed, and the conclusions reached. iii

  1. Performance testing of a hydrogen heat pipe

    International Nuclear Information System (INIS)

    Alario, J.; Kosson, R.

    1980-01-01

    Test results are presented for a reentrant groove heat pipe with hydrogen working fluid. The heat pipe became operational between 20 and 30 K after a cooldown from 77 K without any difficulty. Steady-state performance data taken over a 19 to 23 K temperature range indicated the following: (1) maximum heat transport capacity 5.4 W-m (2) static wicking height 1.42 cm and (3) overall heat pipe conductance 1.7 W/C. These data agreed remarkably well with extrapolations made from comparable ammonia test results. The maximum heat transport capacity is 9.5% larger than the extrapolated value, but the static wicking height is the same. The overall conductance is 29% of the ammonia value, which is close to the ratio of liquid thermal conductivities (24%). Also, recovery from a completely frozen condition was accomplished within 5 min by simply applying an evaporater heat load of 1.8 W

  2. Pharmacists performing quality spirometry testing: an evidence based review.

    Science.gov (United States)

    Cawley, Michael J; Warning, William J

    2015-10-01

    The scope of pharmacist services for patients with pulmonary disease has primarily focused on drug related outcomes; however pharmacists have the ability to broaden the scope of clinical services by performing diagnostic testing including quality spirometry testing. Studies have demonstrated that pharmacists can perform quality spirometry testing based upon international guidelines. The primary aim of this review was to assess the published evidence of pharmacists performing quality spirometry testing based upon American Thoracic Society/European Respiratory Society (ATS/ERS) guidelines. In order to accomplish this, the description of evidence and type of outcome from these services were reviewed. A literature search was conducted using five databases [PubMed (1946-January 2015), International Pharmaceutical Abstracts (1970 to January 2015), Cumulative Index of Nursing and Allied Health Literature, Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews] with search terms including pharmacy, spirometry, pulmonary function, asthma or COPD was conducted. Searches were limited to publications in English and reported in humans. In addition, Uniform Resource Locators and Google Scholar searches were implemented to include any additional supplemental information. Eight studies (six prospective multi-center trials, two retrospective single center studies) were included. Pharmacists in all studies received specialized training in performing spirometry testing. Of the eight studies meeting inclusion and exclusion criteria, 8 (100%) demonstrated acceptable repeatability of spirometry testing based upon standards set by the ATS/ERS guidelines. Acceptable repeatability of seven studies ranged from 70 to 99% consistent with published data. Available evidence suggests that quality spirometry testing can be performed by pharmacists. More prospective studies are needed to add to the current evidence of quality spirometry testing performed by

  3. Radon detection system, design, test and performance

    International Nuclear Information System (INIS)

    Balcazar, M.; Chavez, A.; Pina-Villalpando, G.; Navarrete, M.

    1999-01-01

    A portable radon detection system (α-Inin) has been designed and constructed for using it in adverse environmental conditions where humidity, temperature and chemical vaporous are present. The minimum integration time is in periods of 15 min during 41 days. A 12 V battery and a photovoltaic module allow the α-Inin autonomy in field measurements. Data is collected by means of a laptop computer where data processing and α-Inin programming are carried out. α-Inin performance was simultaneously tested in a controlled radon chamber, together with a commercial α-Meter

  4. Performance test of wet type decontamination device

    International Nuclear Information System (INIS)

    Lee, E. P.; Kim, E. G.; Min, D. K.; Jun, Y. B.; Lee, H. K.; Seu, H. S.; Kwon, H. M.; Hong, K.P.

    2003-01-01

    The intervention area located at rear hot cell can be contaminated by hot cell maintenance work. For effective decontamination of the intervention floor a wet type decontamination device was developed. The device was assembled with a brush rotating part, a washing liquid supplying part, an intake part for recovering contaminated liquid and a device moving cart part. The device was made of stainless steel for easy decontamination and corrosion resistance. The function test carried out at intervention area of the PIE facility showed good performance

  5. Performance testing of UK personal dosimetry laboratories

    CERN Document Server

    Marshall, T O

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it...

  6. Performance testing of UK personal dosimetry laboratories

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it are also estimated. (author)

  7. Performance and durability testing of parabolic trough receivers

    Science.gov (United States)

    Lei, Dongqiang; Fu, Xuqiang; Zhao, Dongming; Yuan, Guofeng; Wang, Zhifeng; Guo, Minghuan

    2017-06-01

    The paper describes the key performance and durability testing facilities of the parabolic trough receiver developed by Institute of Electrical Engineering, Chinese Academy of Sciences. The indoor heat loss test can be applied at 4-7 different temperature levels within 200-550 on receivers. The optical efficiency test bench consists of 12 metal halide lamps as the solar simulator and a 5 m length half-elliptical cylinder reflector with flat end reflectors. 3 ultra-precision temperature sensors are used in receiver each end to get the temperature difference. The residual gas analysis test bench is applied to analyze and predict the vacuum lifetime of the receiver. It can test the variations of composition and partial pressure of residual gases with temperature and time in the receiver annulus space by a high sensitivity quadrupole mass spectrometer gas analyzer. A coating accelerated ageing test bench, which is also used to test the thermal cycle, has been developed. This test bench uses the absorber tube of the recevier as the resistance heater to heat up the whole receiver. The coating lifetime can be predicted by the Arrhenius parameters. For the cycling test, the compressed air is used to directly cool the inner surface of the absorber tube. The thermal cycling test is performed with temperature cycles from 150 °C to 450 °C for 160 cycles. The maximum thermal cycling frequency is 8 cycles per day. The mechanical fatigue test bench is used to test the bellows and the glass-to-metal seals durability at the same time. Both bellows are expanded and compressed to 6.5 mm in turn with 10,000 cycles. A new rotating test bench was also developed to test the thermal efficiency of the receiver.

  8. On the (In)Consistency of Citizen and Municipal Level Indicators of Social Capital and Local Government Performance.

    Science.gov (United States)

    Kampen, Jarl K

    2010-06-01

    We study the empirical consistency of survey based (micro level) indicators of social capital and local government performance on the one, and municipality based (aggregate level) measures of these two concepts on the other hand. Knowledge about the behavior of these indicators is helpful for evaluating the value of studies carried out in isolated contexts, that is, with access to data on either, but not both, levels. The method is by comparing data collected by Statistics Belgium on Flemish municipalities, to data collected at citizen level by means of a face-to-face survey. The available evidence supplies at best a meager basis for presupposing a shared component of the indicators under study.

  9. Testing after Worked Example Study Does Not Enhance Delayed Problem-Solving Performance Compared to Restudy

    Science.gov (United States)

    van Gog, Tamara; Kester, Liesbeth; Dirkx, Kim; Hoogerheide, Vincent; Boerboom, Joris; Verkoeijen, Peter P. J. L.

    2015-01-01

    Four experiments investigated whether the testing effect also applies to the acquisition of problem-solving skills from worked examples. Experiment 1 (n?=?120) showed no beneficial effects of testing consisting of "isomorphic" problem solving or "example recall" on final test performance, which consisted of isomorphic problem…

  10. Standard specification for agencies performing nondestructive testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This specification covers minimum requirements for agencies performing nondestructive testing (NDT). 1.2 When using this specification to assess the capability of, or to accredit NDT agencies, Guide E 1359 shall be used as a basis for the survey. It can be supplemented as necessary with more detail in order to meet the auditor's specific needs. 1.3 This specification can be used as a basis to evaluate testing or inspection agencies, or both, and is intended for use for the qualifying or accrediting, or both, of testing or inspection agencies, public or private. 1.4 The use of SI or inch-pound units, or combination thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to...

  11. Predicting neuropsychological test performance on the basis of temporal orientation.

    Science.gov (United States)

    Ryan, Joseph J; Glass, Laura A; Bartels, Jared M; Bergner, CariAnn M; Paolo, Anthony M

    2009-05-01

    Temporal orientation is often disrupted in the context of psychiatric or neurological disease; tests assessing this function are included in most mental status examinations. The present study examined the relationship between scores on the Temporal Orientation Scale (TOS) and performance on a battery of tests that assess memory, language, and cognitive functioning in a sample of patients with Alzheimer's disease (N = 55). Pearson-product moment correlations showed that, in all but two instances, the TOS was significantly correlated with each neuropsychological measure, p values < or = .05. Also, severely disoriented (i.e., TOS score < or = -8) patients were consistently 'impaired' on memory tests but not on tests of language and general cognitive functioning.

  12. Enhanced photoelectrochemical performance of inorganic–organic hybrid consisting of BiVO{sub 4} and PEDOT:PSS

    Energy Technology Data Exchange (ETDEWEB)

    Trzciński, K. [Faculty of Chemistry, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk (Poland); Szkoda, M., E-mail: mariusz-szkoda@wp.pl [Faculty of Chemistry, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk (Poland); Siuzdak, K.; Sawczak, M. [Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid Flow Machinery, Fiszera 14, 80-231 Gdańsk (Poland); Lisowska-Oleksiak, A., E-mail: alo@pg.gda.pl [Faculty of Chemistry, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk (Poland)

    2016-12-01

    Highlights: • Bismuth vanadate layers were prepared using pulsed laser deposition technique. • The modification method of BiVO{sub 4} by PEDOT:PSS was developed. • Modified layers exhibited higher photoactivity than bare BiVO{sub 4}. • Prepared material can act as semiconducting layer in photoelectrochemical cells. - Abstract: The PEDOT:PSS (poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate)) was electrodeposited on a thin layer of bismuth vanadate (BiVO{sub 4}) prepared using the pulsed laser deposition technique onto FTO. The inorganic–organic junction was characterized by Raman spectroscopy, UV–vis spectroscopy and scanning electron microscopy. Chronoamperometry curves, recorded under simulated solar light illumination, were performed to determine generated photocurrent during water and hydroquinone oxidation at the electrode surface. Experiments were performed for three types of electrode materials: (i) FTO/BiVO{sub 4}, (ii) FTO/PEDOT:PSS and (iii) FTO/BiVO{sub 4}/PEDOT:PSS in aqueous electrolyte. Almost 5 times higher photocurrent in electrolyte containing hole scavenger was generated after modification of BiVO{sub 4} photoanode with electrodeposited polymer. It is noteworthy that anodic photocurrent was stable even after 4 h of illumination. Cyclic voltammetry curves of FTO/BiVO{sub 4}/PEDOT:PSS recorded before and after experiments performed under electrode illumination indicated that the organic part in tested junction is photo-corrosion resistant.

  13. CFC and HFC recycling equipments: Test performances

    International Nuclear Information System (INIS)

    Picini, P.; Caropreso, G.; Cicoli, G.; Posarelli, M.

    1996-12-01

    Actual regulatory conditions about ozone layer depleting chemicals set problems on their disposal and on the management of plants still using illegal CFCs. Anyway fluids that will replace CFCs (i.e. HFCs) will not be allowed to be spread into the atmosphere, due to their high costs and to the greenhouse effect. A viable solution would be the recovery, purification and recycle of contaminated fluids. ENEA (National Agency for New Technology, Energy and the Environment), in cooperation with ICF (Industria Componenti Frigoriferi) Company leader in the field of air refrigerating and conditioning, patented a device able to extract, to clean and to recycle CFC 12 and HFC 134a in the refrigerating systems. This paper presents experimental data from the qualification tests on a device performing the above mentioned operations regarding systems that use HFC 134a as process fluid

  14. A consistent and predictable commercial broiler chicken bacterial microbiota in antibiotic-free production displays strong correlations with performance.

    Science.gov (United States)

    Johnson, Timothy J; Youmans, Bonnie P; Noll, Sally; Cardona, Carol; Evans, Nicholas P; Karnezos, T Peter; Ngunjiri, John M; Abundo, Michael C; Lee, Chang-Won

    2018-04-06

    Defining the baseline bacterial microbiome is critical towards understanding its relationship with health and disease. In broiler chickens, the core microbiome and its possible relationships with health and disease have been difficult to define due to high variability between birds and flocks. Presented are data from a large, comprehensive microbiota-based study in commercial broilers. The primary goals of this study included understanding what constitutes the core bacterial microbiota in the broiler gastrointestinal, respiratory, and barn environments; how these core players change across age, geography, and time; and which bacterial taxa correlate with enhanced bird performance in antibiotic-free flocks. Using 2,309 samples from 37 different commercial flocks within a vertically integrated broiler system, and metadata from these and an additional 512 flocks within that system, the baseline bacterial microbiota was defined using 16S rRNA gene sequencing. The effects of age, sample type, flock, and successive flock cycles were compared, and results indicate a consistent, predictable, age-dependent bacterial microbiota, irrespective of flock. The tracheal bacterial microbiota of broilers was comprehensively defined, and Lactobacillus was the dominant bacterial taxa in the trachea. Numerous bacterial taxa were identified which were strongly correlated with broiler chicken performance, across multiple tissues. While many positively correlated taxa were identified, negatively associated potential pathogens were also identified in the absence of clinical disease, indicating subclinical dynamics occurring that impact performance. Overall, this work provides necessary baseline data for the development of effective antibiotic alternatives, such as probiotics, for sustainable poultry production. Importance Multidrug resistant bacterial pathogens are perhaps the greatest medical challenge we will face in the 21 st century and beyond. Antibiotics are necessary in animal

  15. Can trained lay providers perform HIV testing services? A review of national HIV testing policies.

    Science.gov (United States)

    Flynn, David E; Johnson, Cheryl; Sands, Anita; Wong, Vincent; Figueroa, Carmen; Baggaley, Rachel

    2017-01-04

    Only an estimated 54% of people living with HIV are aware of their status. Despite progress scaling up HIV testing services (HTS), a testing gap remains. Delivery of HTS by lay providers may help close this testing gap, while also increasing uptake and acceptability of HIV testing among key populations and other priority groups. 50 National HIV testing policies were collated from WHO country intelligence databases, contacts and testing program websites. Data regarding lay provider use for HTS was extracted and collated. Our search had no geographical or language restrictions. This data was then compared with reported data from the Global AIDS Response Progress Reporting (GARPR) from July 2015. Forty-two percent of countries permit lay providers to perform HIV testing and 56% permit lay providers to administer pre-and post-test counseling. Comparative analysis with GARPR found that less than half (46%) of reported data from countries were consistent with their corresponding national HIV testing policy. Given the low uptake of lay provider use globally and their proven use in increasing HIV testing, countries should consider revising policies to support lay provider testing using rapid diagnostic tests.

  16. Boxing headguard performance in punch machine tests.

    Science.gov (United States)

    McIntosh, Andrew S; Patton, Declan A

    2015-09-01

    The paper presents a novel laboratory method for assessing boxing headguard impact performance. The method is applied to examine the effects of headguards on head impact dynamics and injury risk. A linear impactor was developed, and a range of impacts was delivered to an instrumented Hybrid III head and neck system both with and without an AIBA (Association Internationale de Boxe Amateur)-approved headguard. Impacts at selected speeds between 4.1 and 8.3 m/s were undertaken. The impactor mass was approximately 4 kg and an interface comprising a semirigid 'fist' with a glove was used. The peak contact forces were in the range 1.9-5.9 kN. Differences in head impact responses between the Top Ten AIBA-approved headguard and bare headform in the lateral and forehead tests were large and/or significant. In the 8.3 m/s fist-glove impacts, the mean peak resultant headform accelerations for bare headform tests was approximately 130 g compared with approximately 85 g in the forehead impacts. In the 6.85 m/s bare headform impacts, mean peak resultant angular head accelerations were in the range of 5200-5600 rad/s(2) and almost halved by the headguard. Linear and angular accelerations in 45° forehead and 60° jaw impacts were reduced by the headguard. The data support the opinion that current AIBA headguards can play an important role in reducing the risk of concussion and superficial injury in boxing competition and training. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. MOTIVATION AND PERFORMANCE IN PHYSICAL EDUCATION: AN EXPERIMENTAL TEST

    Directory of Open Access Journals (Sweden)

    Juan A. Moreno

    2010-03-01

    Full Text Available The purpose of this study was to analyse, experimentally, the relationships between motivation and performance in a lateral movement test in physical education. The study group consisted of 363 students (227 boys and 136 girls, aged between 12 and 16, who were randomly divided into three groups: an experimental group in which an incremental ability belief was induced, another experimental group in which an entity ability belief was induced, and a control group where there was no intervention. Measurements were made of situational intrinsic motivation, perceived competence in executing the task and performance. The results revealed that the incremental group reported higher scores on the situational intrinsic motivation scale. The entity group demonstrated better performance in the first test attempt than the incremental group but, in the second attempt, the performance was similar in the different groups. Perhaps the initial differences in performance disappeared because the incremental group counted on improving in the second attempt. These results are discussed in relation to the intensity with which the teacher conveys information relating to incremental ability belief of the pupil to increase intrinsic motivation and performance

  18. Performance evaluation of the Solar Building Test Facility

    Science.gov (United States)

    Jensen, R. N.

    1981-01-01

    The general performance of the NASA Solar Building Test Facility (SBTF) and its subsystems and components over a four year operational period is discussed, and data are provided for a typical one year period. The facility consists of a 4645 sq office building modified to accept solar heated water for operation of an absorption air conditioner and a baseboard heating system. An adjoining 1176 sq solar flat plate collector field with a 114 cu tank provides the solar heated water. The solar system provided 57 percent of the energy required for heating and cooling on an annual basis. The average efficiency of the solar collectors was 26 percent over a one year period.

  19. Differences in gender performance on competitive physics selection tests

    Science.gov (United States)

    Wilson, Kate; Low, David; Verdon, Matthew; Verdon, Alix

    2016-12-01

    [This paper is part of the Focused Collection on Gender in Physics.] We have investigated gender differences in performance over the past eight years on the Australian Science Olympiad Exam (ASOE) for physics, which is taken by nearly 1000 high school students each year. The ASOE, run by Australian Science Innovations (ASI), is the initial stage of the process of selection of teams to represent Australia at the Asian and International Physics Olympiads. Students taking the exam are generally in their penultimate year of school and selected by teachers as being high performing in physics. Together with the overall differences in facility, we have investigated how the content and presentation of multiple-choice questions (MCQs) affects the particular answers selected by male and female students. Differences in the patterns of responses by male and female students indicate that males and females might be modeling situations in different ways. Some strong patterns were found in the gender gaps when the questions were categorized in five broad dimensions: content, process required, difficulty, presentation, and context. Almost all questions saw male students performing better, although gender differences were relatively small for questions with a more abstract context. Male students performed significantly better on most questions with a concrete context, although notable exceptions were found, including two such questions where female students performed better. Other categories that showed consistently large gaps favoring male students include questions with projectile motion and other two-dimensional motion or forces content, and processes involving interpreting diagrams. Our results have important implications, suggesting that we should be able to reduce the gender gaps in performance on MCQ tests by changing the way information is presented and setting questions in contexts that are less likely to favor males over females. This is important as MCQ tests are

  20. Differences in gender performance on competitive physics selection tests

    Directory of Open Access Journals (Sweden)

    Kate Wilson

    2016-08-01

    Full Text Available [This paper is part of the Focused Collection on Gender in Physics.] We have investigated gender differences in performance over the past eight years on the Australian Science Olympiad Exam (ASOE for physics, which is taken by nearly 1000 high school students each year. The ASOE, run by Australian Science Innovations (ASI, is the initial stage of the process of selection of teams to represent Australia at the Asian and International Physics Olympiads. Students taking the exam are generally in their penultimate year of school and selected by teachers as being high performing in physics. Together with the overall differences in facility, we have investigated how the content and presentation of multiple-choice questions (MCQs affects the particular answers selected by male and female students. Differences in the patterns of responses by male and female students indicate that males and females might be modeling situations in different ways. Some strong patterns were found in the gender gaps when the questions were categorized in five broad dimensions: content, process required, difficulty, presentation, and context. Almost all questions saw male students performing better, although gender differences were relatively small for questions with a more abstract context. Male students performed significantly better on most questions with a concrete context, although notable exceptions were found, including two such questions where female students performed better. Other categories that showed consistently large gaps favoring male students include questions with projectile motion and other two-dimensional motion or forces content, and processes involving interpreting diagrams. Our results have important implications, suggesting that we should be able to reduce the gender gaps in performance on MCQ tests by changing the way information is presented and setting questions in contexts that are less likely to favor males over females. This is important as MCQ

  1. Harmonic pulse testing for well performance monitoring

    NARCIS (Netherlands)

    Fokker, Peter A.; Salina Borello, Eloisa; Verga, Francesca; Viberti, Dario

    2018-01-01

    Harmonic testing was developed as a form of well testing that can be applied during ongoing production or injection operations, as a pulsed signal is superimposed on the background pressure trend. Thus no interruption of well and reservoir production is needed before and during the test. If the

  2. Spent fuel metal storage cask performance testing and future spent fuel concrete module performance testing

    International Nuclear Information System (INIS)

    McKinnon, M.A.; Creer, J.M.

    1988-10-01

    REA-2023 Gesellshaft fur Nuklear Service (GNS) CASTOR-V/21, Transnuclear TN-24P, and Westinghouse MC-10 metal storage casks, have been performance tested under the guidance of the Pacific Northwest Laboratory to determine their thermal and shielding performance. The REA-2023 cask was tested under Department of Energy (DOE) sponsorship at General Electric's facilities in Morris, Illinois, using BWR spent fuel from the Cooper Reactor. The other three casks were tested under a cooperative agreement between Virginia Power Company and DOE at the Idaho National Engineering Laboratory (INEL) by EGandG Idaho, Inc., using intact spent PWR fuel from the Surry reactors. The Electric Power Research Institute (EPRI) made contributions to both programs. A summary of the various cask designs and the results of the performance tests is presented. The cask designs include: solid and liquid neutron shields; lead, steel, and nodular cast iron gamma shields; stainless steel, aluminum, and copper baskets; and borated materials for criticality control. 4 refs., 8 figs., 6 tabs

  3. Consistency tests of Ampcalculator and chiral amplitudes in SU(3) Chiral Perturbation Theory: A tutorial-based approach

    International Nuclear Information System (INIS)

    Ananthanarayan, B.; Sentitemsu Imsong, I.; Das, Diganta

    2012-01-01

    Ampcalculator (AMPC) is a Mathematica copyright based program that was made publicly available some time ago by Unterdorfer and Ecker. It enables the user to compute several processes at one loop (upto O(p 4 )) in SU(3) chiral perturbation theory. They include computing matrix elements and form factors for strong and non-leptonic weak processes with at most six external states. It was used to compute some novel processes and was tested against well-known results by the original authors. Here we present the results of several thorough checks of the package. Exhaustive checks performed by the original authors are not publicly available, and hence the present effort. Some new results are obtained from the software especially in the kaon odd-intrinsic parity non-leptonic decay sector involving the coupling G 27 . Another illustrative set of amplitudes at tree level we provide is in the context of τ-decays with several mesons including quark mass effects, of use to the BELLE experiment. All eight meson-meson scattering amplitudes have been checked. The Kaon-Compton amplitude has been checked and a minor error in the published results has been pointed out. This exercise is a tutorial-based one, wherein several input and output notebooks are also being made available as ancillary files on the arXiv. Some of the additional notebooks we provide contain explicit expressions that we have used for comparison with established results. The purpose is to encourage users to apply the software to suit their specific needs. An automatic amplitude generator of this type can provide error-free outputs that could be used as inputs for further simplification, and in varied scenarios such as applications of chiral perturbation theory at finite temperature, density and volume. This can also be used by students as a learning aid in low-energy hadron dynamics. (orig.)

  4. Does computer-synthesized speech manifest personality? Experimental tests of recognition, similarity-attraction, and consistency-attraction.

    Science.gov (United States)

    Nass, C; Lee, K M

    2001-09-01

    Would people exhibit similarity-attraction and consistency-attraction toward unambiguously computer-generated speech even when personality is clearly not relevant? In Experiment 1, participants (extrovert or introvert) heard a synthesized voice (extrovert or introvert) on a book-buying Web site. Participants accurately recognized personality cues in text to speech and showed similarity-attraction in their evaluation of the computer voice, the book reviews, and the reviewer. Experiment 2, in a Web auction context, added personality of the text to the previous design. The results replicated Experiment 1 and demonstrated consistency (voice and text personality)-attraction. To maximize liking and trust, designers should set parameters, for example, words per minute or frequency range, that create a personality that is consistent with the user and the content being presented.

  5. Interface Consistency

    DEFF Research Database (Denmark)

    Staunstrup, Jørgen

    1998-01-01

    This paper proposes that Interface Consistency is an important issue for the development of modular designs. Byproviding a precise specification of component interfaces it becomes possible to check that separately developedcomponents use a common interface in a coherent matter thus avoiding a very...... significant source of design errors. Awide range of interface specifications are possible, the simplest form is a syntactical check of parameter types.However, today it is possible to do more sophisticated forms involving semantic checks....

  6. Results of performance tests on polymer zirconium compound (PZC)

    International Nuclear Information System (INIS)

    Sombrito, Elvira Z.; Bulos, Adelina DM.

    2006-01-01

    Three batches of polyzirconium compound (PZC) consisting of nine samples were tested for its application as column material for adsorbing reactor-produced molybdenum-99 ( 99 Mo). Using low specific activity molybdenum solution (∼500 μCi/267 mg Mo), the adsorption capacity, elution yield, elution volume and molybdenum breakthrough were measured. The average adsorption capacity of the nine samples is 239 ± 17 mg Mo/g PZC. The elution yield values obtained are lower than previously obtained and averaged at 47% with 30% variability. Molybdenum breakthrough also exceeded the limits for 99m Tc eluates. Considering the better performance of 2002 PZC samples, the samples may have undergone some changes during storage (tests were performed in December 2003) and/or the adsorption process did not conform to the recommended procedure. If this were the case, it demonstrated the importance of strictly following the recommended protocol. Relative values showed that the last two batches (PZC 030718 and PC 030726) performed better than the first batch in terms of elution yield and elution profile. These two batches exhibited amorphous structure as seen by x-ray diffraction analysis of the PZC test samples. (author)

  7. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Gannon, J.; Kraushaar, P.; Mcinturff, A.; Nehring, R.; Saladin, V.; Savord, T.; Sorrensen, G.; Smellie, R.; Tool, G.; Voy, D.

    1993-05-01

    The intent of the Accelerator System String Test (ASST) is to obtain data for model verification and information on the magnitudes of pressures and voltages encountered in an accelerator environment. The ASST milestone run was achieved during July and August, 1992 and consisted of demonstrating the accelerator components could be configured together as a system operating at full current. Following the milestone run, the string was warmed to counteract some design flaws that impeded the operational range. The string was again cooled to cryogenic temperatures in October, and a comprehensive power testing program was conducted through the end of January, 1993. This paper describes how the collider arc components operate in an accelerator environment during quenches induced by firing both strip heaters and spot heaters. Evaluation of the data illustrates how variations in the design parameters on magnets used in a string environment can impact system performance

  8. Performance Tests of CMSSW on the CernVM

    CERN Document Server

    Petek, Marko

    2012-01-01

    goal of allowing the execution of the experiment's software on different operating systems in an easy way for the users. To achieve this it makes use of Virtual Machine images consisting of a JEOS (Just Enough Operational System) Linux image, bundled with CVMFS, a distributed file system for software. This image can this be run with a proper virtualizer on most of the platforms available. It also aggressively caches data on the local user's machine so that it can operate disconnected from the network. CMS wanted to compare the performance of the CMS Software running in the virtualized environment with the same software running on a native Linux box. To answer this need a series of tests were made on a controlled environment during 2010-2011. This work presents the results of those tests.

  9. Small-scale tunnel test for blast performance

    International Nuclear Information System (INIS)

    Felts, J E; Lee, R J

    2014-01-01

    The data reported here provide a validation of a small-scale tunnel test as a tool to guide the optimization of new explosives for blast performance in tunnels. The small-scale arrangement consisted of a 2-g booster and 10-g sample mounted at the closed end of a 127 mm diameter by 4.6-m long steel tube with pressure transducers along its length. The three performance characteristics considered were peak pressure, initial energy release, and impulse. The relative performance from five explosives was compared to that from a 1.16-m diameter by 30-m long tunnel that used 2.27-kg samples. The peak pressure values didn't correlate between the tunnels. Partial impulse for the explosives did rank similarly. The initial energy release was determined from a one-dimensional point-source analysis, which nearly tracked with impulse suggesting additional energy released further down the tunnel for some explosives. This test is a viable tool for optimizing compositional variations for blast performance in target scenarios of similar geometry.

  10. Test plan for dig-face characterization performance testing

    International Nuclear Information System (INIS)

    Josten, N.E.

    1993-09-01

    The dig-face characterization concept has been under development at the Idaho National Engineering Laboratory (INEL) since FY 1992 through the support of the Buried Waste Integrated Demonstration Program. A Dig-face Characterization System conducts continuous subsurface characterization simultaneously with retrieval of hazardous and radioactive waste from buried waste sites. The system deploys multiple sensors at the retrieval operation dig-face and collects data that provide a basis for detecting, locating, and identifying hazardous conditions before they are disturbed by the retrieval equipment. This test plan describes initial efforts to test the dig-face characterization concept at the INEL Cold Test Pit using a simplified prototype apparatus and off-the-shelf sensors. The Cold Test Pit is a simulated waste site containing hazardous and radioactive waste surrogates at known locations. Testing will be directed toward three generic characterization problems: metal detection, plume detection, and radioactive source detection. The prototype apparatus will gather data using magnetometers, a ground conductivity meter, a trace gas analyzer, and a gamma ray sensor during simulated retrieval of the surrogate waste materials. The data acquired by a dig-face characterization system are unique because of the high precision, high data density, and multiple viewpoints attainable through the dig-face deployment approach. The test plan establishes procedures for collecting and validating a representative dig-face characterization data set. Analysis of these data will focus on developing criteria for predicting the depth, location, composition, and other characteristics of the surrogate waste materials. If successful, this proof-of-concept exercise will provide a foundation for future development of a fully-operational system that is capable of operating on an actual waste site

  11. Software development for simplified performance tests and weekly performance check in Younggwang NPP Unit 3 and 4

    International Nuclear Information System (INIS)

    Hur, K. Y.; Jang, S. H.; Lee, J. W.; Kim, J. T.; Park, J. C.

    2002-01-01

    This paper covers the current status of turbine cycle performance test in nuclear power plants and the software development which can solve some shortcomings related to performance tests. The software developed is for simplified performance tests and weekly performance checks in Yonggwang nuclear power plant unit 3 and 4. This software includes the requirements from the efficiency division for the consistency with actual performance analysis work and the usability of the collected performance test data. From the working survey, we identify the difference between the embedded performance analysis modules and the actual performance analysis work. This software helps operation or maintenance personnel to reduce work load, to support the trend analysis of essential parameters in a turbine cycle, and to utilize the correction curves for the decision-making in their work

  12. Proof of Performance Test Report MANTIS

    National Research Council Canada - National Science Library

    2005-01-01

    ... (NVESD), Humanitarian Demining Branch (HD), the assessment was conducted by HD staff members and supported by engineers from the United Kingdom under the auspices of the International Evaluation Test Program for Humanitarian Demining (ITEP...

  13. The relationship between standardised test performance and ...

    African Journals Online (AJOL)

    The English language proficiency of South African learners is integral to ... in standardised reading/writing tests in English Second Language (ESL) and (2) the use of ... and their relationship with the ESL learner's language learning strategies.

  14. Accelerated Performance Testing on the 2006 NCAT Pavement Test Track

    Science.gov (United States)

    2009-12-01

    The original National Center for Asphalt Technology (NCAT) Pavement Test Track was built in 2000 in Opelika, Alabama where it has served as a state-of-the-art, full-scale, closed-loop accelerated loading facility. The construction, operation, and res...

  15. Self-consistency and sum-rule tests in the Kramers-Kronig analysis of optical data: Applications to aluminum

    International Nuclear Information System (INIS)

    Shiles, E.; Sasaki, T.; Inokuti, M.; Smith, D.Y.

    1980-01-01

    An iterative, self-consistent procedure for the Kramers-Kronig analysis of data from reflectance, ellipsometric, transmission, and electron-energy-loss measurements is presented. This procedure has been developed for practical dispersion analysis since experimentally no single optical function can be readily measured over the entire range of frequencies as required by the Kramers-Kronig relations. The present technique is applied to metallic aluminum as an example. The results are then examined for internal consistency and for systematic errors by various optical sum rules. The present procedure affords a systematic means of preparing a self-consistent set of optical functions provided some optical or energy-loss data are available in all important spectral regions. The analysis of aluminum discloses that currently available data exhibit an excess oscillator strength, apparently in the vicinity of the L edge. A possible explanation is a systematic experimental error in the absorption-coefficient measurements resulting from surface layers: possibly oxides: present in thin-film transmission samples. A revised set of optical functions has been prepared by an ad hoc reduction of the reported absorption coefficient above the L edge by 14%. These revised data lead to a total oscillator strength consistent with the known electron density and are in agreement with dc-conductivity and stopping-power measurements as well as with absorption coefficients inferred from the cross sections of neighboring elements in the periodic table. The optical functions resulting from this study show evidence for both the redistribution of oscillator strength between energy levels and the effects on real transitions of the shielding of conduction electrons by virtual processes in the core states

  16. Phase 1: ISOCELL demonstration test performance review

    International Nuclear Information System (INIS)

    Chatwin, T.D.

    1991-04-01

    This document consolidates and organizes information available concerning cryogenic retrieval of hazardous, radioactive, and mixed wastes and is mainly derived from a report on the ISOCELL Demonstration Project prepared by Concept RKK, Ltd. ISOCELL cryogenic technology is designed to immobilize hazardous, radioactive, and mixed waste by creating a block of frozen waste and soil that can be safely retrieved, stored, transported, and treated with a minimum of dust. A test of the ISOCELL process was conducted in Carnation, Washington by Concept RKK, Ltd. Test conditions were compared to possible testing conditions at Idaho National Engineering Laboratory. Results indicate ISOCELL technology successfully froze wet soil into a soil block capable of being lifted. 5 refs., 6 figs., 1 tab

  17. Comparison of performance test for protective aprons

    International Nuclear Information System (INIS)

    Fukutomi, Yukimi; Yoshimoto, Masahiro; Kawakami, Toshiaki

    1989-01-01

    Each one radioprotective apron (lead equivalent, 0.35 mmPb) was commercially available in November 1988 from 7 domestic and 3 foreign companies. According to the JIS standards 4803, these aprons were evaluated for the following items: 1) display of aprons, including packing and the structure; 2) non-breaking test, including appearance, size, lead equivalent, and uniformity; 3) breaking test, including lead equivalent, uniformity, stregth, and structure; 4) feeling of wearing an apron. An overall evaluation revealed that only two aprons were in accordance with the JIS standard. Careful wearing of the protective apron is stressed. (N.K.)

  18. An Audit of Repeat Testing at an Academic Medical Center: Consistency of Order Patterns With Recommendations and Potential Cost Savings.

    Science.gov (United States)

    Hueth, Kyle D; Jackson, Brian R; Schmidt, Robert L

    2018-05-31

    To evaluate the prevalence of potentially unnecessary repeat testing (PURT) and the associated economic burden for an inpatient population at a large academic medical facility. We evaluated all inpatient test orders during 2016 for PURT by comparing the intertest times to published recommendations. Potential cost savings were estimated using the Centers for Medicare & Medicaid Services maximum allowable reimbursement rate. We evaluated result positivity as a determinant of PURT through logistic regression. Of the evaluated 4,242 repeated target tests, 1,849 (44%) were identified as PURT, representing an estimated cost-savings opportunity of $37,376. Collectively, the association of result positivity and PURT was statistically significant (relative risk, 1.2; 95% confidence interval, 1.1-1.3; P < .001). PURT contributes to unnecessary health care costs. We found that a small percentage of providers account for the majority of PURT, and PURT is positively associated with result positivity.

  19. 10 CFR 26.168 - Blind performance testing.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Blind performance testing. 26.168 Section 26.168 Energy... and Human Services § 26.168 Blind performance testing. (a) Each licensee and other entity shall submit blind performance test samples to the HHS-certified laboratory. (1) During the initial 90-day period of...

  20. GPS Device Testing Based on User Performance Metrics

    Science.gov (United States)

    2015-10-02

    1. Rationale for a Test Program Based on User Performance Metrics ; 2. Roberson and Associates Test Program ; 3. Status of, and Revisions to, the Roberson and Associates Test Program ; 4. Comparison of Roberson and DOT/Volpe Programs

  1. Testing After Worked Example Study Does Not Enhance Delayed Problem-Solving Performance Compared to Restudy

    NARCIS (Netherlands)

    T.A.J.M. van Gog (Tamara); L. Kester (Liesbeth); K. Dirkx (Kim); V. Hoogerheide (Vincent); J. Boerboom (Joris); P.P.J.L. Verkoeijen (Peter)

    2015-01-01

    textabstractFour experiments investigated whether the testing effect also applies to the acquisition of problem-solving skills from worked examples. Experiment 1 (n = 120) showed no beneficial effects of testing consisting of isomorphic problem solving or example recall on final test performance,

  2. Testing After Worked Example Study Does Not Enhance Delayed Problem-Solving Performance Compared to Restudy

    NARCIS (Netherlands)

    Van Gog, Tamara; Kester, Liesbeth; Dirkx, Kim; Hoogerheide, Vincent; Boerboom, Joris; Verkoeijen, Peter P. J. L.

    2016-01-01

    Four experiments investigated whether the testing effect also applies to the acquisition of problem-solving skills from worked examples. Experiment 1 (n=120) showed no beneficial effects of testing consisting of isomorphic problem solving or example recall on final test performance, which

  3. Testing After Worked Example Study Does Not Enhance Delayed Problem-Solving Performance Compared to Restudy

    NARCIS (Netherlands)

    van Gog, Tamara; Kester, Liesbeth; Dirkx, Kim; Hoogerheide, Vincent; Boerboom, Joris; Verkoeijen, Peter P J L

    Four experiments investigated whether the testing effect also applies to the acquisition of problem-solving skills from worked examples. Experiment 1 (n = 120) showed no beneficial effects of testing consisting of isomorphic problem solving or example recall on final test performance, which

  4. Factors affecting the auction price of Veldram performance tested ...

    African Journals Online (AJOL)

    The popularity of these auctions for performance tested rams (89.4 % of rams sold) indicate that Veld tested rams were sought after by buyers. The sale price of 296 Veld tested Dorper rams sold between 1994 and 2001, covering seven different tests, were compared with their measured and observed performances.

  5. Impact of Alzheimer's Disease on Caregiver Questionnaire: internal consistency, convergent validity, and test-retest reliability of a new measure for assessing caregiver burden.

    Science.gov (United States)

    Cole, Jason C; Ito, Diane; Chen, Yaozhu J; Cheng, Rebecca; Bolognese, Jennifer; Li-McLeod, Josephine

    2014-09-04

    There is a lack of validated instruments to measure the level of burden of Alzheimer's disease (AD) on caregivers. The Impact of Alzheimer's Disease on Caregiver Questionnaire (IADCQ) is a 12-item instrument with a seven-day recall period that measures AD caregiver's burden across emotional, physical, social, financial, sleep, and time aspects. Primary objectives of this study were to evaluate psychometric properties of IADCQ administered on the Web and to determine most appropriate scoring algorithm. A national sample of 200 unpaid AD caregivers participated in this study by completing the Web-based version of IADCQ and Short Form-12 Health Survey Version 2 (SF-12v2™). The SF-12v2 was used to measure convergent validity of IADCQ scores and to provide an understanding of the overall health-related quality of life of sampled AD caregivers. The IADCQ survey was also completed four weeks later by a randomly selected subgroup of 50 participants to assess test-retest reliability. Confirmatory factor analysis (CFA) was implemented to test the dimensionality of the IADCQ items. Classical item-level and scale-level psychometric analyses were conducted to estimate psychometric characteristics of the instrument. Test-retest reliability was performed to evaluate the instrument's stability and consistency over time. Virtually none (2%) of the respondents had either floor or ceiling effects, indicating the IADCQ covers an ideal range of burden. A single-factor model obtained appropriate goodness of fit and provided evidence that a simple sum score of the 12 items of IADCQ can be used to measure AD caregiver's burden. Scales-level reliability was supported with a coefficient alpha of 0.93 and an intra-class correlation coefficient (for test-retest reliability) of 0.68 (95% CI: 0.50-0.80). Low-moderate negative correlations were observed between the IADCQ and scales of the SF-12v2. The study findings suggest the IADCQ has appropriate psychometric characteristics as a

  6. SIMS prototype system 4 - performance test report

    Science.gov (United States)

    1978-01-01

    A self-contained, preassembled air type solar system, designed for installation remote from the dwelling, to provide space heating and hot water was evaluated. Data analysis is included which documents the system performance and verifies its suitability for field installation.

  7. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    International Nuclear Information System (INIS)

    Cuevas V, G.; Avila N, A.; Calleros M, G.

    2013-10-01

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  8. Gamma thermometer longevity test: Laguna Verde 2 instruments recent performance

    Energy Technology Data Exchange (ETDEWEB)

    Cuevas V, G. [Global Nuclear Fuel, Americas, 3901 Castle Hayne Road, Wilmington, North Carolina (United States); Avila N, A.; Calleros M, G., E-mail: Gabriel.Cuevas-Vivas@gnf.com [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verda, Carretera Veracruz-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2013-10-15

    This paper is informative of the General Electric Hitachi and Global Nuclear Fuel - Americas are collaboration with Comision Federal de Electricidad in a longevity test of thermocouples as power monitoring devices. The test conclusions will serve for final engineering design in detailing the Automated Fixed In-core Probes for calibration of the Local Power Range Monitors (LPRMs) of the Economic Simplified Boiling Water Reactor. This paper introduces the collaboration description and some recent performance evaluation of the thermocouples that are sensitive to gamma radiation and are known generically as Gamma Thermometers (G T). The G Ts in Laguna Verde 2 are radially located inside six instrumentation tubes in the core and consist of seven thermocouples, four are aligned with the LPRM heights and three are axially located between LPRM heights. The Laguna Verde 2 G T test has become the longest test of thermocouples as power monitoring devices in a BWR industry history and confirms their reliability in terms of time-dependent small noise under steady state reactor conditions and good agreement against Traversing In-core Probes power measurements. (Author)

  9. Test results of the SMES model coil. Pulse performance

    International Nuclear Information System (INIS)

    Hamajima, Takataro; Shimada, Mamoru; Ono, Michitaka

    1998-01-01

    A model coil for superconducting magnetic energy storage (SMES model coil) has been developed to establish the component technologies needed for a small-scale 100 kWh SMES device. The SMES model coil was fabricated, and then performance tests were carried out in 1996. The coil was successfully charged up to around 30 kA and down to zero at the same ramp rate of magnetic field experienced in a 100 kWh SMES device. AC loss in the coil was measured by an enthalpy method as parameters of ramp rate and flat top current. The results were evaluated by an analysis and compared with short-sample test results. The measured hysteresis loss is in good agreement with that estimated from the short-sample results. It was found that the coupling loss of the coil consists of two major coupling time constants. One is a short time constant of about 200 ms, which is in agreement with the test results of a short real conductor. The other is a long time constant of about 30 s, which could not be expected from the short sample test results. (author)

  10. Characterization and Performance Testing of Natural Gas Compressors for Residential and Commercial Applications

    Science.gov (United States)

    Zhang, Xinye; Groll, Eckhard A.; Bethel, Dylan

    2017-08-01

    Relatively little information is available in the literature with respect to the performance of compressors used during the dynamic charging process of a tank. Therefore, work presented in this paper shows the measurement results of performance testing of a natural gas compressor and analyses the compressor characterization based on the experimental data. Initial tests were conducted using air and carbon dioxide given the thermodynamic similarities between these fluids and natural gas. Finally, a new test stand was specifically designed and built for compressor dynamic testing using pipeline natural gas (NG) and the compressor reliability has been evaluated inside an explosion-proof engine test cell. Reliability tests at standard operating conditions monitored the performance consistency of the compressors over the testing period and the testing consisted of a series of tank charges aimed at evaluating the maximum operating temperature as well as the mass flow rate in the system.

  11. Characterisation of the hydrodynamic properties within THE EDZ around drifts at level - 490 m of the Bure URL: a methodology for consistent interpretation of hydraulic tests

    International Nuclear Information System (INIS)

    Baechler, S.; Lavanchy, J.M.; Armand, G.; Cruchaudet, M.

    2010-01-01

    realistic manner) the combined effects of the EDZ around the drift and the mechanical disturbance due to drilling. Independent information from other investigation methods were used to critically revise the conceptual model and formation parameters. In particular, the absence of break-out in the borehole section close to the drift suggests that there is no additional mechanical disturbance induced by drilling in the pre-existing EDZ around a drift. Furthermore, preliminary information from the diffusion experiment (DIR) within undisturbed rock sections could confirm that the mechanically disturbed zone around a borehole may not exceed about 0.1 m (approximately one borehole diameter). Therefore several critical tests series from previous investigations were reanalysed using a revised conceptual model, constraining the extent of the mechanical disturbed zone around the borehole (conceptualized as a circular sheath around the test interval with a higher permeability than the formation further away from the borehole). The results of the reanalyses, performed with the numerical borehole simulator MULTISIM, are presented. The conclusions of the reanalyses in this borehole can be summarized as follows: - The test data could be reasonably fitted with the new constraints on the conceptual model. - In some cases the good quality of the simulations was, however, directly associated with higher storativity values of the EDZ (realistic considering unsaturated conditions). - Overall the new simulation results obtained from selected test series performed at various times are more consistent, without unexplained variations of the EDZ properties over time (i.e. permeability, storage coefficient). - The new conductivity profile indicates lower values between 0.8 and 2.0 m, which is consistent with drill core observations. - The significant decrease in permeability over 2.5 years between 0.3 and 0.5 m is confirmed. There has been no significant change of permeability since 2005 beyond 0.8 m

  12. Drop performance test and evaluation for HANARO shutoff units

    International Nuclear Information System (INIS)

    Jung, Y. H.; Cho, Y. K.; Lee, J. H.; Choi, Y. S.; Woo, J. S.

    2004-01-01

    The function of the shutoff units of the HANARO is to rapidly insert the shutoff rod into the reactor core for safe shutdown of reactor. This paper describes drop performance test and evaluation for a shutoff unit for the technical verification of lifetime extension and localization of the HANARO shutoff units. We have performed preliminary drop performance tests for a shutoff unit at 1/2-core test loop and analyzed through the comparison with the test results performed during design verification test and the results of the periodic performance test in HANARO. It shows that the results of the local fabrication, installation and alignment for the shutoff unit meet the basic performance requirements, Furthermore, the performance evaluation method of the periodic drop test of the HANARO shutoff units is a conservative method comparing with the real drop time

  13. Improving Students' Language Performance Through Consistent Use of E-Learning: An Empirical Study in Japanese, Korean, Hindi and Sanskrit

    Directory of Open Access Journals (Sweden)

    Sara LIBRENJAK

    2016-12-01

    Full Text Available This paper describes the backing theories, methodology, and results of a two-semester long case study of the application of technology in teaching four Asian languages (Japanese, Korean, Hindi, and Sanskrit to Croatian students. We have developed e-learning materials to follow the curriculum in Croatia and deployed them in Asian language classrooms. Students who agreed to participate in the study were tested before using the materials, and after each semester, and their progress was surveyed. In the case of Japanese students (N=53, we have thoroughly monitored their usage and compared the progress of students who have diligently studied vocabulary and grammar using our materials on Memrise, and those who have neglected their studies. This was measured through their scores on the Memrise, which shows the user's activity. Also, their progress was measured using standardized tests that were designed in such a manner to resemble Japanese Language Proficiency Test. We have found that frequent users progressed averagely 20,3% after each semester, while non-frequent users have progressed only 11,6%, proving this method to be related to stable and constant use of e-materials.

  14. Measuring the Consistency in Change in Hepatitis B Knowledge among Three Different Types of Tests: True/False, Multiple Choice, and Fill in the Blanks Tests.

    Science.gov (United States)

    Sahai, Vic; Demeyere, Petra; Poirier, Sheila; Piro, Felice

    1998-01-01

    The recall of information about Hepatitis B demonstrated by 180 seventh graders was tested with three test types: (1) short-answer; (2) true/false; and (3) multiple-choice. Short answer testing was the most reliable. Suggestions are made for the use of short-answer tests in evaluating student knowledge. (SLD)

  15. Performance Test of Alpha Spectrometry for Environmental Radioactivity Analysis

    International Nuclear Information System (INIS)

    Choi, Jung Youn; Yoon, Jong-Ho; Han, Ki-Tek; Ahn, Gil Hoon

    2015-01-01

    Environmental samples are analyzed by various methods such as, ICP-MS (inductively coupled plasma mass spectrometry), AMS (accelerator mass spectrometry) TIMS (thermal ionization mass spectrometry), HRGS (high resolution gamma spectrometry) and alpha /beta particle analysis. In this study, we will described the result of performance test using alpha spectrometry for analyzing environmental samples. Measurement data of the U activity using SRM based on extraction chromatography with UTEVA resin. It should be effective way to separate of uranium isotope for the measurement of alpha spectrometry. But, the result of this measurement data is higher than another recovery data. Also concentration of U data is lack of consistency. We leave out of consideration many effect of factors about influence in the experiment process. In the future work, we will try to reduce the step of experiment process and reflect the uncertainty factors

  16. Performance-based containment leakage testing

    International Nuclear Information System (INIS)

    Cybulskis, P.

    1995-01-01

    The U.S. Nuclear Regulatory Commission (NRC) is reviewing regulatory requirements in an effort to revise those that are marginal to safety but impose significant burdens on licensees. Identification of requirements marginal to safety and development and evaluation of alternatives utilize the NRC safety goals and insights from probabilistic risk assessments (PRAs). Since earlier studies found design-basis containment leakage to be a minor contributor to reactor accident risk, containment leakage testing has been selected as a candidate for change in regulations. This paper summarizes the technical analyses supporting the NRC proposal to amend Appendix J of 10 CFR Part 50 as its first effort to decrease unnecessary regulatory burdens on licensees

  17. Experimental test of liquid droplet radiator performance

    Science.gov (United States)

    Mattick, A. T.; Simon, M. A.

    The liquid droplet radiator (LDR) is a heat rejection system for space power systems wherein an array of heated liquid droplets radiates energy directly to space. The use of submillimeter droplets provides large radiating area-to-mass ratio, resulting in radiator systems which are several times lighter than conventional solid surface radiators. An experiment is described in which the power radiated by an array of 2300 streams of silicone oil droplets is measured to test a previously developed theory of the LDR radiation process. This system would be capable of rejecting several kW of heat in space. Furthermore, it would be suitable as a modular unit of an LDR designed for 100-kW power levels. The experiment provided confirmation of the theoretical dependence of droplet array emissivity on optical depth. It also demonstrated the ability to create an array of more than 1000 droplet streams having a divergence less than 1 degree.

  18. DMFC Performance of Polymer Electrolyte Membranes Prepared from a Graft-Copolymer Consisting of a Polysulfone Main Chain and Styrene Sulfonic Acid Side Chains

    Directory of Open Access Journals (Sweden)

    Nobutaka Endo

    2016-08-01

    Full Text Available Polymer electrolyte membranes (PEMs for direct methanol fuel cell (DMFC applications were prepared from a graft-copolymer (PSF-g-PSSA consisting of a polysulfone (PSF main chain and poly(styrene sulfonic acid (PSSA side chains with various average distances between side chains (Lav and side chain lengths (Lsc. The polymers were synthesized by grafting ethyl p-styrenesulfonate (EtSS on macro-initiators of chloromethylated polysulfone with different contents of chloromethyl (CM groups, and by changing EtSS content in the copolymers by using atom transfer radical polymerization (ATRP. The DMFC performance tests using membrane electrode assemblis (MEAs with the three types of the PEMs revealed that: a PSF-g-PSSA PEM (SF-6 prepared from a graft copolymer with short average distances between side chains (Lav and medium Lsc had higher DMFC performance than PEMs with long Lav and long Lsc or with short Lav and short Lsc. SF-6 had about two times higher PDmax (68.4 mW/cm2 than Nafion® 112 at 30 wt % of methanol concentration. Furthermore, it had 58.2 mW/cm2 of PDmax at 50 wt % of methanol concentration because of it has the highest proton selectivity during DMFC operation of all the PSF-g-PSSA PEMs and Nafion® 112.

  19. Basic investigation of the laminated alginate impression technique: Setting time, permanent deformation, elastic deformation, consistency, and tensile bond strength tests.

    Science.gov (United States)

    Kitamura, Aya; Kawai, Yasuhiko

    2015-01-01

    Laminated alginate impression for edentulous is simple and time efficient compared to border molding technique. The purpose of this study was to examine clinical applicability of the laminated alginate impression, by measuring the effects of different Water/Powder (W/P) and mixing methods, and different bonding methods in the secondary impression of alginate impression. Three W/P: manufacturer-designated mixing water amount (standard), 1.5-fold (1.5×) and 1.75-fold (1.75×) water amount were mixed by manual and automatic mixing methods. Initial and complete setting time, permanent and elastic deformation, and consistency of the secondary impression were investigated (n=10). Additionally, tensile bond strength between the primary and secondary impression were measured in the following surface treatment; air blow only (A), surface baking (B), and alginate impression material bonding agent (ALGI-BOND: AB) (n=12). Initial setting times significantly shortened with automatic mixing for all W/P (p<0.05). The permanent deformation decreased and elastic deformation increased as high W/P, regardless of the mixing method. Elastic deformation significantly reduced in 1.5× and 1.75× with automatic mixing (p<0.05). All of these properties resulted within JIS standards. For all W/P, AB showed a significantly high bonding strength as compared to A and B (p<0.01). The increase of mixing water, 1.5× and 1.75×, resulted within JIS standards in setting time, suggesting its applicability in clinical setting. The use of automatic mixing device decreased elastic strain and shortening of the curing time. For the secondary impression application of adhesives on the primary impression gives secure adhesion. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  20. Performance tests of the reactor containment structures of HTTR

    International Nuclear Information System (INIS)

    Sakaba, Nariaki; Iigaki, Kazuhiko; Kawaji, Satoshi; Iyoku, Tatsuo

    1998-03-01

    The containment structures of the HTTR consist of the reactor containment vessel (CV), service area (SA) and emergency air purification system, which minimize the release of FPs in the postulated accidents with FP release from the reactor facilities. The CV is designed to withstand the temperature and pressure transients and to be leak-tight within the specified leakage limit even in the case of a rupture of the primary concentric hot gas duct. The pressure of inside of the SA should be maintained slightly lower than that of atmosphere by the emergency air purification system. The radioactive materials are released from the stack to environment via the emergency air purification system under the accident condition. Then the emergency air purification system should remove airborne radio-activities and should maintain proper pressure in the SA. We established the method to measure leak rate of the CV with closed reactor coolant pressure boundary although it is normally measured under opened reactor coolant pressure boundary as employed in LWRs. The CV leak rate test was carried out by the newly developed method and the expected performance was obtained. The SA and emergency air purification system were also confirmed by the performance test. We concluded that the reactor containment structures were fabricated to minimize the release of FPs in the postulated accidents with FP release from the reactor facilities. (author)

  1. Stirling convertor performance mapping test results

    Science.gov (United States)

    Qiu, Songgang; Peterson, Allen A.; White, Maurice A.; Faultersack, Franklyn; Redinger, Darin L.; Petersen, Stephen L.

    2002-01-01

    The Department of Energy (DOE) has selected Free-Piston Stirling Convertors as a technology for future advanced radioisotope space power systems. In August 2000, DOE awarded competitive Phase I, Stirling Radioisotope Generator (SRG) power system integration contracts to three major aerospace contractors, resulting in SRG conceptual designs in February 2001. All three contractors based their designs on the Technology Demonstration Convertor (TDC) developed by Stirling Technology Company (STC) for DOE. The contract award to a single system integration contractor for Phases II and III of the SRG program is anticipated in late 2001. The first potential SRG mission is targeted for a Mars rover. Recent TDC performance data are provided in this paper, together with predictions from Stirling simulation models. .

  2. New test methods for BIPV. Results from IP performance

    International Nuclear Information System (INIS)

    Jol, J.C.; Van Kampen, B.J.M.; De Boer, B.J.; Reil, F.; Geyer, D.

    2009-11-01

    Within the Performance project new test procedures for PV building products and the building performance as a whole when PV is applied in buildings have been drafted. It has resulted in a first draft of new test procedures for PV building products and proposals for tests for novel BIPV technology like thin film. The test proposed are a module breakage test for BIPV products, a fire safety test for BIPV products and a dynamic load test for BIPV products. Furthermore first proposals of how flexible PV modules could be tested in an appropriate way to ensure long time quality and safety of these new products are presented.

  3. The Performance of Surfactant-Polymer Flooding in Horizontal Wells Consisting of Multilayers in a Reservoir System

    Directory of Open Access Journals (Sweden)

    Si Le Van

    2016-03-01

    Full Text Available Surfactant-polymer (SP flooding has been demonstrated to be an effective method to recover oil in the enhanced oil recovery (EOR stage when water flooding is no longer relevant. Theoretically, adding surfactant causes the reduction of the interfacial tension between oil and water in pores, therefore reducing the residual oil saturation, whereas the sweep efficiency will be significantly improved by the polymer injection as a result of proper mobility control. With regard to the well patterns, water flooding has demonstrated a high productivity in horizontal wells. Recently, other EOR processes have been increasingly applied to the horizontal wells in various well patterns. In this study, the efficiency of SP flooding applied to horizontal wells in various well configurations is investigated in order to select the best EOR performance in terms of either a technical or economical point of view. Furthermore, the reservoir is assumed to be anisotropic with four different layers that have same porosity but different permeability between each layer. The study figures out that, the utilization of a horizontal injector and producer always gives a higher oil production in comparison with the reference case of a conventional vertical injector and producer; however, the best EOR performances that demonstrate the higher oil recovery and lower fluid injected volume than those of the reference case are achieved when the production well is located in bottom layers and parallel with the injection well at a distance. While the location of producer decides oil productivity, the location of injector yet affects the uniformity of fluids propagation in the reservoir. A predefined feasibility factor is also taken into consideration in order to reject the infeasible cases that might give a high oil production but require a higher injected volume than the reference case. This factor is used as an economic parameter to evaluate the success of the EOR performance. The

  4. Experimental test of liquid droplet radiator performance

    International Nuclear Information System (INIS)

    Mattick, A.T.; Simon, M.A.

    1986-01-01

    This liquid droplet radiator (LDR) is evolving rapidly as a lightweight system for heat rejection in space power systems. By using recirculating free streams of submillimeter droplets to radiate waste energy directly to space, the LDR can potentially be an order of magnitude lighter than conventional radiator systems which radiate from solid surfaces. The LDR is also less vulnerable to micrometeoroid damage than are conventional radiators, and it has a low transport volume. Three major development issues of this new heat rejection system are the ability to direct the droplet streams with sufficient precision to avoid fluid loss, radiative performance of the array of droplet streams which comprise the radiating elements of the LDR, and the efficacy of the droplet stream collector, again with respect to fluid loss. This paper reports experimental results bearing on the first two issues - droplet aiming in a multikilowatt-sized system, and radiated power from a large droplet array. Parallel efforts on droplet collection and LDR system design are being pursued by several research groups

  5. Internal consistency, reliability, and temporal stability of the Oxford Happiness Questionnaire short-form: Test-retest data over two weeks

    OpenAIRE

    MCGUCKIN, CONOR

    2006-01-01

    PUBLISHED The Oxford Happiness Questionnaire short-form is a recently developed eight-item measure of happiness. This study evaluated the internal consistency reliability and test-retest reliability of the Oxford Happiness Questionnaire short-form among 55 Northern Irish undergraduate university students who completed the measure on two occasions separated by two weeks. Internal consistency of the measure on both occasions was satisfactory at both Time 1 (alpha = .62) and Time 2 (alpha = ....

  6. Fenestration System Performance Research, Testing, and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jim Benney

    2009-11-30

    The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be

  7. Use of the SSF equations in the Kojima-Moon-Ochi thermodynamic consistency test of isothermal vapour-liquid equilibrium data

    Directory of Open Access Journals (Sweden)

    SLOBODAN P. SERBANOVIC

    2000-12-01

    Full Text Available The Kojima-Moon-Ochi (KMO thermodynamic consistency test of vapour–liquid equilibrium (VLE measurements for 32 isothermal data sets of binary systems of various complexity was applied using two fitting equations: the Redlich-Kister equation and the Sum of Symmetrical Functions. It was shown that the enhanced reliability of the fitting of the experimental data can change the conclusions drawn on their thermodynamic consistency in those cases of VLE data sets that are estimated to be near the border of consistency.

  8. Reliability performance testing of totally encapsulating chemical protective suits

    International Nuclear Information System (INIS)

    Johnson, J.S.; Swearengen, P.M.

    1991-01-01

    The need to assure a high degree of reliability for totally encapsulating chemical protective (TECP) suits has been recognized by Lawrence Livermore National Laboratory's (LLNL) Hazards Control Department for some time. The following four tests were proposed as necessary to provide complete evaluation of TECP suit performance: 1. Quantitative leak test (ASTM draft), 2. Worst-case chemical exposure test (conceptual), 3. Pressure leak-rate test (complete, ASTM F1057-87), and 4. Chemical leak-rate test (ASTM draft). This paper reports on these tests which should be applied to measuring TECP suit performance in two stages: design qualification tests and field use tests. Test 1, 2, and 3 are used as design qualification tests, and tests 3 and 4 are used as field use tests

  9. High performance organic integrated device with ultraviolet photodetective and electroluminescent properties consisting of a charge-transfer-featured naphthalimide derivative

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hanyu; Wang, Xu; Yu, Junsheng, E-mail: luzhiyun@scu.edu.cn, E-mail: jsyu@uestc.edu.cn [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Zhou, Jie; Lu, Zhiyun, E-mail: luzhiyun@scu.edu.cn, E-mail: jsyu@uestc.edu.cn [College of Chemistry, Sichuan University, Chengdu 610064 (China)

    2014-08-11

    A high performance organic integrated device (OID) with ultraviolet photodetective and electroluminescent (EL) properties was fabricated by using a charge-transfer-featured naphthalimide derivative of 6-(3,5-bis-[9-(4-t-butylphenyl)-9H-carbazol-3-yl]-phenoxy)-2- (4-t-butylphenyl)-benzo[de]isoquinoline-1,3-dione (CzPhONI) as the active layer. The results showed that the OID had a high detectivity of 1.5 × 10{sup 11} Jones at −3 V under the UV-350 nm illumination with an intensity of 0.6 mW/cm{sup 2}, and yielded an exciplex EL light emission with a maximum brightness of 1437 cd/m{sup 2}. Based on the energy band diagram, both the charge transfer feature of CzPhONI and matched energy level alignment were responsible for the dual ultraviolet photodetective and EL functions of OID.

  10. Development of performance tests for an automated MC and A system

    International Nuclear Information System (INIS)

    Kok, K.D.; Klingensmith, R.W.; Riffle, W.; Carver, R.D.; Schumacher, S.S.; Lavender, J.C.; Smith, B.W.

    1988-01-01

    Performance tests of MC and A systems using computers are described, and some example scenarios are discussed. Facility personnel or an external inspection group may use performance tests to evaluate MC and A capabilities under actual operating conditions. This paper addresses test elements common to both user groups. Performance tests consist of scenario development, security, and safety measures, conduct, and evaluation. Because exercises often test scenarios against which the MC and A system is protecting, they may require additional security and safety measures. Computer systems enhance MC and A by providing greater speed, increased precision, and automated checks. Performance tests for MC and A systems using computers differ from performance tests employing manual data systems in that the scenarios must anticipate computer actions rather than utilize controllers to adjust the scenario

  11. Freeze-thaw performance testing of whole concrete railroad ties.

    Science.gov (United States)

    2013-10-01

    Freezing and thawing durability tests of prestressed concrete ties are normally performed according to ASTM C666 specifications. Small specimens are cut from the shoulders of concrete ties and tested through 300 cycles of freezing and thawing. Saw-cu...

  12. The performance test of NAA laboratory at radionuclide measure with low activity

    International Nuclear Information System (INIS)

    Sri Murniasih; Sukirno

    2016-01-01

    The performance test to measure the I-131 radionuclide activity has been carried out at CAST-NAA laboratory. The purpose of this activity is to know the performance of a laboratory in the testing of low radioactivity sample. The tested sample consists of the form I-131 radionuclide sources shaped thin plastic disk with a certain weight. Evaluation of laboratory performance test results carried out by the organizer of the program test appeal (PTKMR-BATAN). Evaluation results showed that testing of point source of the I-131 radionuclide with comparative method gives a good enough results with errors below 10%. The results of the performance test evaluation are useful as the external quality control to a testing method that is expected in NAA laboratory. (author)

  13. Testing the performance of technical trading rules in the Chinese markets based on superior predictive test

    Science.gov (United States)

    Wang, Shan; Jiang, Zhi-Qiang; Li, Sai-Ping; Zhou, Wei-Xing

    2015-12-01

    Technical trading rules have a long history of being used by practitioners in financial markets. The profitable ability and efficiency of technical trading rules are yet controversial. In this paper, we test the performance of more than seven thousand traditional technical trading rules on the Shanghai Securities Composite Index (SSCI) from May 21, 1992 through June 30, 2013 and China Securities Index 300 (CSI 300) from April 8, 2005 through June 30, 2013 to check whether an effective trading strategy could be found by using the performance measurements based on the return and Sharpe ratio. To correct for the influence of the data-snooping effect, we adopt the Superior Predictive Ability test to evaluate if there exists a trading rule that can significantly outperform the benchmark. The result shows that for SSCI, technical trading rules offer significant profitability, while for CSI 300, this ability is lost. We further partition the SSCI into two sub-series and find that the efficiency of technical trading in sub-series, which have exactly the same spanning period as that of CSI 300, is severely weakened. By testing the trading rules on both indexes with a five-year moving window, we find that during the financial bubble from 2005 to 2007, the effectiveness of technical trading rules is greatly improved. This is consistent with the predictive ability of technical trading rules which appears when the market is less efficient.

  14. Analysis of the Qualification-Tests Performance of the Superconducting Cavities for the SNS Linac

    CERN Document Server

    Delayen, J R; Ozelis, O

    2004-01-01

    Thomas Jefferson National Accelerating Facility (Jefferson Lab) is producing superconducting radio frequency (SRF) cryomodules for the Spallation Neutron Source (SNS) cold linac. This consists of 11 medium-beta (β=0.61) cyomodules of 3 cavities each, and 12 high-beta (β=0.81) cryomodules of 4 cavities each. Before assembly into cavity strings the cavities undergo individual qualification tests in a vertical cryostat (VTA). In this paper we analyze the performance of the cavities during these qualification tests, and attempt to correlate this performance with cleaning, assembly, and testing procedures. We also compare VTA performance with performance in completed cryomodules.

  15. Performance test of uninterruptible power system of PIEF

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Chae; Kim, Eun Ka; Chun, Yong Bum; Park, Dea Gyu; Chu, Yong Sun; Bae, Sang Min; Koo, Dae Seo

    1998-02-01

    Because of the special features of post-irradiation examination (PIE) facility to handle very high radioactive materials like spent nuclear fuels, the electric system of the facility was designed and constructed according to a very strict requirement which is applied to nuclear power plant. A safety grade of Class 1E was adopted in the power utility system of PIEF to guarantee stable power supply to the facility without any expected interruption. In order cope with a emergency condition like a power interruption of KEPCO, a emergency power supplying system consisting of a diesel generator (3-phase, 6600/440, 1,000 kW) and uninterruptibel power supply (UPS) system was installed in PIEF. UPS power is connected to the radiation monitoring system and several other main safety devices to assure of normal operations of them for not less than 30 minutes. According to the recommendations and regulations in nuclear law, a monthly and yearly regular inspection for the UPS and emergency power supplying system are performed. In this report, a brief description to establish self-inspection technology and procedures for the above mentioned electric power supplying system at PIEF, including a principle of operation, inspection scheme, trouble shooting, and performance test techniques were made. (author). 8 refs., 3 tabs., 4 figs.

  16. Is cosmology consistent?

    International Nuclear Information System (INIS)

    Wang Xiaomin; Tegmark, Max; Zaldarriaga, Matias

    2002-01-01

    We perform a detailed analysis of the latest cosmic microwave background (CMB) measurements (including BOOMERaNG, DASI, Maxima and CBI), both alone and jointly with other cosmological data sets involving, e.g., galaxy clustering and the Lyman Alpha Forest. We first address the question of whether the CMB data are internally consistent once calibration and beam uncertainties are taken into account, performing a series of statistical tests. With a few minor caveats, our answer is yes, and we compress all data into a single set of 24 bandpowers with associated covariance matrix and window functions. We then compute joint constraints on the 11 parameters of the 'standard' adiabatic inflationary cosmological model. Our best fit model passes a series of physical consistency checks and agrees with essentially all currently available cosmological data. In addition to sharp constraints on the cosmic matter budget in good agreement with those of the BOOMERaNG, DASI and Maxima teams, we obtain a heaviest neutrino mass range 0.04-4.2 eV and the sharpest constraints to date on gravity waves which (together with preference for a slight red-tilt) favor 'small-field' inflation models

  17. 40 CFR 63.2354 - What performance tests, design evaluations, and performance evaluations must I conduct?

    Science.gov (United States)

    2010-07-01

    ... evaluations, and performance evaluations must I conduct? 63.2354 Section 63.2354 Protection of Environment... tests, design evaluations, and performance evaluations must I conduct? (a)(1) For each performance test... procedures specified in subpart SS of this part. (3) For each performance evaluation of a continuous emission...

  18. Recommended procedures for performance testing of radiobioassay laboratories: Volume 2, In vitro samples

    International Nuclear Information System (INIS)

    Fenrick, H.W.; MacLellan, J.A.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard specifies the criteria for defining the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of in vitro test samples (artificial urine and fecal matter) for indirect bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented. 8 refs., 3 tabs

  19. Shaking table test study on seismic performance of dehydrogenation fan for nuclear power plants

    International Nuclear Information System (INIS)

    Liu Kaiyan; Shi Weixing; Cao Jialiang; Wang Yang

    2011-01-01

    Seismic performance of the dehydrogenation fan for nuclear power plants was evaluated based on the shaking table test of earthquake simulation. Dynamic characteristics including the orthogonal tri-axial fundamental frequencies and equivalent damping ratios were measured by the white noise scanning method. Artificial seismic waves were generated corresponding to the floor acceleration response spectra for nuclear power plants. Furthermore, five OBE and one SSE shaking table tests for dehydrogenation fan were performed by using the artificial seismic waves as the seismic inputs along the orthogonal axis simultaneity. Operating function of dehydrogenation fan was monitored and observed during all seismic tests, and performance indexes of dehydrogenation fan were compared before and after seismic tests. The results show that the structural integrity and operating function of the dehydrogenation fan are perfect during all seismic tests; and the performance indexes of the dehydrogenation fan can remain consistent before and after seismic tests; the seismic performance of the dehydrogenation fan can satisfy relevant technical requirements. (authors)

  20. 40 CFR 63.309 - Performance tests and procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Performance tests and procedures. 63.309 Section 63.309 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Standards for Coke Oven Batteries § 63.309 Performance tests and procedures. (a) Except as otherwise...

  1. Beam test performance of the SKIROC2 ASIC

    CERN Document Server

    Frisson, T; Anduze, M; Augustin, J.E; Bonis, J; Boudry, V; Bourgeois, C; Brient, J.C; Callier, S; Cerutti, M; Chen, S; Cornat, R; Cornebise, P; Cuisy, D; David, J; De la Taille, C; Dulucq, F; Frotin, M; Gastaldi, F; Ghislain, P; Giraud, J; Gonnin, A; Grondin, D; Guliyev, E; Hostachy, J.Y; Jeans, D; Kamiya, Y; Kawagoe, K; Kozakai, C; Lacour, D; Lavergne, L; Lee, S.H; Magniette, F; Ono, H; Poeschl, R; Rouëné, J; Seguin-Moreau, N; Song, H.S; Sudo, Y; Thiebault, A; Tran, H; Ueno, H; Van der Kolk, N; Yoshioka, T

    2015-01-01

    Beam tests of the first layers of CALICE silicon tungsten ECAL technological prototype were performed in April and July 2012 using 1–6 GeV electron beam at DESY. This paper presents an analysis of the SKIROC2 readout ASIC performance under test beam conditions.

  2. Towards Smart Buildings Performance Testing as a Service

    DEFF Research Database (Denmark)

    Markoska, Elena; Lazarova-Molnar, Sanja

    2018-01-01

    to buildings’ energy consumption. In this paper we propose a methodology for continuous performance testing of smart buildings as a service. We discuss the automatic discovery and instantiation of performance tests, as well as usage of results for discovery of potential faults and ways to improve buldings...

  3. Impact of Educational Level on Performance on Auditory Processing Tests.

    Science.gov (United States)

    Murphy, Cristina F B; Rabelo, Camila M; Silagi, Marcela L; Mansur, Letícia L; Schochat, Eliane

    2016-01-01

    Research has demonstrated that a higher level of education is associated with better performance on cognitive tests among middle-aged and elderly people. However, the effects of education on auditory processing skills have not yet been evaluated. Previous demonstrations of sensory-cognitive interactions in the aging process indicate the potential importance of this topic. Therefore, the primary purpose of this study was to investigate the performance of middle-aged and elderly people with different levels of formal education on auditory processing tests. A total of 177 adults with no evidence of cognitive, psychological or neurological conditions took part in the research. The participants completed a series of auditory assessments, including dichotic digit, frequency pattern and speech-in-noise tests. A working memory test was also performed to investigate the extent to which auditory processing and cognitive performance were associated. The results demonstrated positive but weak correlations between years of schooling and performance on all of the tests applied. The factor "years of schooling" was also one of the best predictors of frequency pattern and speech-in-noise test performance. Additionally, performance on the working memory, frequency pattern and dichotic digit tests was also correlated, suggesting that the influence of educational level on auditory processing performance might be associated with the cognitive demand of the auditory processing tests rather than auditory sensory aspects itself. Longitudinal research is required to investigate the causal relationship between educational level and auditory processing skills.

  4. Performance testing framework for smart grid communication network

    International Nuclear Information System (INIS)

    Quang, D N; See, O H; Chee, L L; Xuen, C Y; Karuppiah, S

    2013-01-01

    Smart grid communication network is comprised of different communication mediums and technologies. Performance evaluation is one of the main concerns in smart grid communication system. In any smart grid communication implementation, to determine the performance factor of the network, a testing of an end-to-end process flow is required. Therefore, an effective and coordinated testing procedure plays a crucial role in evaluating the performance of smart grid communications. In this paper, a testing framework is proposed as a guideline to analyze and assess the performance of smart grid communication network.

  5. Timed Online Tests: Do Students Perform Better with More Time?

    Science.gov (United States)

    Portolese, Laura; Krause, Jackie; Bonner, Julie

    2016-01-01

    This article focuses on timed tests and specifically on whether increased time enhances test performance. Three courses during the Winter 2015 term (quizzes n = 573) and three courses over the Spring 2015 term (quizzes n = 600) comprised this sample. Students were given the same tests, but the experimental group (Spring 2015) was given 50% more…

  6. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    /10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus...

  7. Item Response Theory Models for Performance Decline during Testing

    Science.gov (United States)

    Jin, Kuan-Yu; Wang, Wen-Chung

    2014-01-01

    Sometimes, test-takers may not be able to attempt all items to the best of their ability (with full effort) due to personal factors (e.g., low motivation) or testing conditions (e.g., time limit), resulting in poor performances on certain items, especially those located toward the end of a test. Standard item response theory (IRT) models fail to…

  8. High Performance Computing Modernization Program Kerberos Throughput Test Report

    Science.gov (United States)

    2017-10-26

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/5524--17-9751 High Performance Computing Modernization Program Kerberos Throughput Test ...NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 2. REPORT TYPE1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 6. AUTHOR(S) 8. PERFORMING...PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT High Performance Computing Modernization Program Kerberos Throughput Test Report Daniel G. Gdula* and

  9. The 5-choice continuous performance test: evidence for a translational test of vigilance for mice.

    Directory of Open Access Journals (Sweden)

    Jared W Young

    Full Text Available Attentional dysfunction is related to functional disability in patients with neuropsychiatric disorders such as schizophrenia, bipolar disorder, and Alzheimer's disease. Indeed, sustained attention/vigilance is among the leading targets for new medications designed to improve cognition in schizophrenia. Although vigilance is assessed frequently using the continuous performance test (CPT in humans, few tests specifically assess vigilance in rodents.We describe the 5-choice CPT (5C-CPT, an elaboration of the 5-choice serial reaction (5CSR task that includes non-signal trials, thus mimicking task parameters of human CPTs that use signal and non-signal events to assess vigilance. The performances of C57BL/6J and DBA/2J mice were assessed in the 5C-CPT to determine whether this task could differentiate between strains. C57BL/6J mice were also trained in the 5CSR task and a simple reaction-time (RT task involving only one choice (1CRT task. We hypothesized that: 1 C57BL/6J performance would be superior to DBA/2J mice in the 5C-CPT as measured by the sensitivity index measure from signal detection theory; 2 a vigilance decrement would be observed in both strains; and 3 RTs would increase across tasks with increased attentional load (1CRT task<5CSR task<5C-CPT.C57BL/6J mice exhibited superior SI levels compared to DBA/2J mice, but with no difference in accuracy. A vigilance decrement was observed in both strains, which was more pronounced in DBA/2J mice and unaffected by response bias. Finally, we observed increased RTs with increased attentional load, such that 1CRT task<5CSR task<5C-CPT, consistent with human performance in simple RT, choice RT, and CPT tasks. Thus we have demonstrated construct validity for the 5C-CPT as a measure of vigilance that is analogous to human CPT studies.

  10. Irradiation test and performance evaluation of DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Song, K. C.; Moon, J. S.

    2002-05-01

    The objective of the project is to establish the performance evaluation system of DUPIC fuel during the Phase II R and D. In order to fulfil this objectives, irradiation test of DUPIC fuel was carried out in HANARO using the non-instrumented and SPND-instrumented rig. Also, the analysis on the in-reactor behavior analysis of DUPIC fuel, out-pile test using simulated DUPIC fuel as well as performance and integrity assessment in a commercial reactor were performed during this Phase. The R and D results of the Phase II are summarized as follows : - Performance evaluation of DUPIC fuel via irradiation test in HANARO - Post irradiation examination of irradiated fuel and performance analysis - Development of DUPIC fuel performance code (modified ELESTRES) considering material properties of DUPIC fuel - Irradiation behavior and integrity assessment under the design power envelope of DUPIC fuel - Foundamental technology development of thermal/mechanical performance evaluation using ANSYS (FEM package)

  11. Model tests on dynamic performance of RC shear walls

    International Nuclear Information System (INIS)

    Nagashima, Toshio; Shibata, Akenori; Inoue, Norio; Muroi, Kazuo.

    1991-01-01

    For the inelastic dynamic response analysis of a reactor building subjected to earthquakes, it is essentially important to properly evaluate its restoring force characteristics under dynamic loading condition and its damping performance. Reinforced concrete shear walls are the main structural members of a reactor building, and dominate its seismic behavior. In order to obtain the basic information on the dynamic restoring force characteristics and damping performance of shear walls, the dynamic test using a large shaking table, static displacement control test and the pseudo-dynamic test on the models of a shear wall were conducted. In the dynamic test, four specimens were tested on a large shaking table. In the static test, four specimens were tested, and in the pseudo-dynamic test, three specimens were tested. These tests are outlined. The results of these tests were compared, placing emphasis on the restoring force characteristics and damping performance of the RC wall models. The strength was higher in the dynamic test models than in the static test models mainly due to the effect of loading rate. (K.I.)

  12. The Performance test of Mechanical Sodium Pump with Water Environment

    International Nuclear Information System (INIS)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Jeong, Ji-Young; Kim, Jong-Bum; Ko, Bock Seong; Park, Sang Jun; Lee, Yoon Sang

    2015-01-01

    As contrasted with PWR(Pressurized light Water Reactor) using water as a coolant, sodium is used as a coolant in SFR because of its low melting temperature, high thermal conductivity, the high boiling temperature allowing the reactors to operate at ambient pressure, and low neutron absorption cross section which is required to achieve a high neutron flux. But, sodium is violently reactive with water or oxygen like the other alkali metal. So Very strict requirements are demanded to design and fabricate of sodium experimental facilities. Furthermore, performance testing in high temperature sodium environments is more expensive and time consuming and need an extra precautions because operating and maintaining of sodium experimental facilities are very difficult. The present paper describes performance test results of mechanical sodium pump with water which has been performed with some design changes using water test facility in SAM JIN Industrial Co. To compare the hydraulic characteristic of model pump with water and sodium, the performance test of model pump were performed using vender's experimental facility for mechanical sodium pump. To accommodate non-uniform thermal expansion and to secure the operability and the safety, the gap size of some parts of original model pump was modified. Performance tests of modified mechanical sodium pump with water were successfully performed. Water is therefore often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Normal practice to thoroughly test a design or component before applied or installed in reactor is important to ensure the safety and operability in the sodium-cooled fast reactor (SFR). So, in order to estimate the hydraulic behavior of the PHTS pump of DSFR (600 MWe Demonstraion SFR), the performance tests of the model pump such as performance

  13. The Empirical Testing of a Musical Performance Assessment Paradigm

    Science.gov (United States)

    Russell, Brian E.

    2010-01-01

    The purpose of this study was to test a hypothesized model of aurally perceived performer-controlled musical factors that influence assessments of performance quality. Previous research studies on musical performance constructs, musical achievement, musical expression, and scale construction were examined to identify the factors that influence…

  14. Mechanical/structural performance test method of a spacer grid

    International Nuclear Information System (INIS)

    Yoon, Kyung Ho

    2000-06-01

    The spacer grid is one of the main structural components in the fuel assembly, which supports the fuel rods, guides cooling water, and protects the system from an external impact load, such as earthquakes. In order to develop the spacer grid with the high mechanical performance, the mechanical and structural properties of the spacer grids must be extensively examined while designing it. In this report, the mechanical/structural test methods, i.e. the characteristic test of a spacer grid spring or dimple, static buckling test of a partial or full size spacer grid and dynamic impact test of them are described. The characteristic test of a spacer grid spring or dimple is accomplished with universal tensile test machine, a specimen is fixed with test fixture and then applied compressive load. The characteristic test data is saved at loading and unloading event. The static buckling test of a partial or full size spacer grid is executed with the same universal tensile testing machine, a specimen is fixed between cross-heads and then applied the compressive load. The buckling strength is decided the maximum strength at load vs. displacement curve. The dynamic impact test of a partial or full size spacer grid is performed with pendulum type impact machine and free fall shock test machine, a specimen is fixed with test fixture and then applied the impact load by impact hammer. Specially, the pendulum type impact test machine is also possible under the operating temperature because a furnace is separately attached with test machine

  15. Important Details in Performing and Interpreting the Scratch Collapse Test.

    Science.gov (United States)

    Kahn, Lorna C; Yee, Andrew; Mackinnon, Susan E

    2018-02-01

    The utility of the scratch collapse test has been demonstrated in examination of patients with carpal and cubital tunnel syndromes and long thoracic and peroneal nerve compressions. In the authors' clinic, this lesser known test plays a key role in peripheral nerve examination where localization of the nerve irritation or injury is not fully understood. Test utility and accuracy in patients with more challenging presentations likely correlate with tester understanding and experience. This article offers a clear outline of all stages of the test to improve interrater reliability. The nuances of test performance are described, including a description of situations where the scratch collapse test is deemed inappropriate. Four clinical scenarios where the scratch collapse test may be useful are included. Corresponding video content is provided to improve performance and interpretation of the scratch collapse test. Diagnostic, V.

  16. 40 CFR 63.344 - Performance test requirements and test methods.

    Science.gov (United States)

    2010-07-01

    ... electroplating tanks or chromium anodizing tanks. The sampling time and sample volume for each run of Methods 306... Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test... Emissions From Decorative and Hard Chromium Electroplating and Anodizing Operations,” appendix A of this...

  17. Expectancy of an open-book test decreases performance on a delayed closed-book test.

    Science.gov (United States)

    Agarwal, Pooja K; Roediger, Henry L

    2011-11-01

    Two experiments examined the influence of practice with, and the expectancy of, open-book tests (students viewed studied material while taking the test) versus closed-book tests (students completed the test without viewing the studied material) on delayed retention and transfer. Using GRE materials specifically designed for open-book testing, participants studied passages and then took initial open- or closed-book tests. Open-book testing led to better initial performance than closed-book testing, but on a delayed criterial (closed-book) test both types of testing produced similar retention after a two-day delay in Experiment 1. In Experiment 2 participants were informed in advance about the type of delayed criterial test to expect (open- or closed-book). Expecting an open-book test (relative to a closed-book test) decreased participants' time spent studying and their delayed test performance on closed-book comprehension and transfer tests, demonstrating that test expectancy can influence long-term learning. Expectancy of open-book tests may impair long-term retention and transfer compared to closed-book tests, despite superior initial performance on open-book tests and students' preference for open-book tests.

  18. Nuclebras' installations for performance tests of nuclear power plants components

    International Nuclear Information System (INIS)

    Vasconcelos Paiva, I.P. de; Avelar Esteves, F. de; Horta, J.A.L.; Resende, M.F.R.; Pinheiro, R.B.

    1984-01-01

    The reasons for Nuclebras' Nuclear Technology Development Center to implement a laboratory for supporting Brazilian manufactures, giving to them the means for performing functional tests of industrial products, are presented. A brief description of facilities under construction: the components Test Loop and Facility for Testing N.P.P. components under Accident conditions, and other already in operation, as well as its objectives and main technical characteristics. Some test results had already obtained are also presented. (Author) [pt

  19. A Framework for Fully Automated Performance Testing for Smart Buildings

    DEFF Research Database (Denmark)

    Markoska, Elena; Johansen, Aslak; Lazarova-Molnar, Sanja

    2018-01-01

    , setup of performance tests has been manual and labor-intensive and has required intimate knowledge of buildings’ complexity and systems. The emergence of the concept of smart buildings has provided an opportunity to overcome this restriction. In this paper, we propose a framework for automated......A significant proportion of energy consumption by buildings worldwide, estimated to ca. 40%, has yielded a high importance to studying buildings’ performance. Performance testing is a mean by which buildings can be continuously commissioned to ensure that they operate as designed. Historically...... performance testing of smart buildings that utilizes metadata models. The approach features automatic detection of applicable performance tests using metadata queries and their corresponding instantiation, as well as continuous commissioning based on metadata. The presented approach has been implemented...

  20. Relationship of the Basic Attributes Test to Tactical Reconnaissance Pilot Performance

    Science.gov (United States)

    1987-01-01

    ulysk 36 4.. Pscoa- Test: Pefcrman Regression Analysis 66 5. Decsison Making Speed: Ped~cnance Regrssiop Analysis 68 6. Item Recognitio . Pefixmanc...agreement between 12 TRS and 91 TRS supcrvisors. This indicated that those most likely to be faced with the task of determining the performance capabilities...those UPT check flights requiring quick, consistent, and accurate responses. Item Recognitio Test Ihe item recognition test reduced to seven scors. Thet

  1. Test anxiety, perfectionism, goal orientation, and academic performance.

    Science.gov (United States)

    Eum, KoUn; Rice, Kenneth G

    2011-03-01

    Dimensions of perfectionism and goal orientation have been reported to have differential relationships with test anxiety. However, the degree of inter-relationship between different dimensions of perfectionism, the 2 × 2 model of goal orientations proposed by Elliot and McGregor, cognitive test anxiety, and academic performance indicators is not known. Based on data from 134 university students, we conducted correlation and regression analyses to test associations between adaptive and maladaptive perfectionism, four types of goal orientations, cognitive test anxiety, and two indicators of academic performance: proximal cognitive performance on a word list recall test and distal academic performance in terms of grade point average. Cognitive test anxiety was inversely associated with both performance indicators, and positively associated with maladaptive perfectionism and avoidance goal orientations. Adaptive and maladaptive perfectionism accounted for significant variance in cognitive test anxiety after controlling for approach and avoidance goal orientations. Overall, nearly 50% of the variance in cognitive test anxiety could be attributed to gender, goal orientations, and perfectionism. Results suggested that students who are highly test anxious are likely to be women who endorse avoidance goal orientations and are maladaptively perfectionistic.

  2. Exploration of task performance tests in a physics laboratory

    Science.gov (United States)

    Liu, Dan; El Turkey, Houssein

    2017-11-01

    In this article, we investigate the implementation of task performance tests in an undergraduate physics laboratory. Two performance tests were carried out over two semesters using the task of building a DC circuit. The first implementation in Spring 2014 had certain concerns such as the privacy of students’ testing and their ‘trial and error’ attempts. These concerns were addressed in Fall 2015 through implementing a second performance test. The second implementation was administered differently but the content of the two tests was the same. We discuss the validity of both implementations and present the correlation (or lack of) between the time that students needed to complete the tests and their grades from a paper-based laboratory assessment method.

  3. Chemical composition analysis and product consistency tests to support enhanced Hanford waste glass models: Results for the January, March, and April 2015 LAW glasses

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Riley, W. T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Best, D. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-09-03

    In this report, the Savannah River National Laboratory provides chemical analyses and Product Consistency Test (PCT) results for several simulated low activity waste (LAW) glasses (designated as the January, March, and April 2015 LAW glasses) fabricated by the Pacific Northwest National Laboratory. The results of these analyses will be used as part of efforts to revise or extend the validation regions of the current Hanford Waste Treatment and Immobilization Plant glass property models to cover a broader span of waste compositions.

  4. Chemical composition analysis and product consistency tests to support Enhanced Hanford Waste Glass Models. Results for the Augusta and October 2014 LAW Glasses

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Best, D. R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-07-07

    In this report, the Savannah River National Laboratory provides chemical analyses and Product Consistency Test (PCT) results for several simulated low activity waste (LAW) glasses (designated as the August and October 2014 LAW glasses) fabricated by the Pacific Northwest National Laboratory. The results of these analyses will be used as part of efforts to revise or extend the validation regions of the current Hanford Waste Treatment and Immobilization Plant glass property models to cover a broader span of waste compositions.

  5. Chemical composition analysis and product consistency tests supporting refinement of the Nepheline Model for the high aluminum Hanford glass composition region

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Mcclane, D. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-03-01

    In this report, Savannah River National Laboratory provides chemical analyses and Product Consistency Test (PCT) results for a series of simulated high level waste (HLW) glasses fabricated by Pacific Northwest National Laboratory (PNNL) as part of an ongoing nepheline crystallization study. The results of these analyses will be used to improve the ability to predict crystallization of nepheline as a function of composition and heat treatment for glasses formulated at high alumina concentrations.

  6. Chemical composition analysis and product consistency tests supporting refinement of the Nepheline model for the high aluminum Hanford Glass composition region

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K. M. [Savannah River Site (SRS), Aiken, SC (United States); Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States); Mcclane, D. L. [Savannah River Site (SRS), Aiken, SC (United States)

    2016-02-17

    In this report, SRNL provides chemical analyses and Product Consistency Test (PCT) results for a series of simulated HLW glasses fabricated by Pacific Northwest National Laboratory (PNNL) as part of an ongoing nepheline crystallization study. The results of these analyses will be used to improve the ability to predict crystallization of nepheline as a function of composition and heat treatment for glasses formulated at high alumina concentrations.

  7. Personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, Christopher G.

    2008-01-01

    The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11. Now in it's fourth edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Laboratory Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by U.S. Nuclear Regulatory Commission (NRC) regulations. The U.S. Department of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Department of Energy Laboratory Accreditation Program (DOELAP). One of the goals of this current revision was the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonization to U.S. personal dosemeter performance testing. The testing philosophy of ANSI/HPS N13.11 has always combined elements of type testing and routine performance testing and is thus different from the testing philosophy used in the rest of the world. In this paper, the history of performance testing in the U.S. is briefly reviewed. Also described is the revision that produced the fourth edition of this standard, which has taken place over the last three years (2005-2008) by a working group representing national standards laboratories, government laboratories, the military, dosimetry vendors, universities and the nuclear power industry. (author)

  8. The study of the energetic performance in test cycles

    Science.gov (United States)

    Rentea, Cristian; Tuca, Alexandra; Oprean, Mircea; Marius, Bataus

    2017-10-01

    One of the most important subsystems of modern passenger cars is the transmission. This paper aims to investigate the global performances of a modern transmission in different test cycles including the newly introduced WLTC (Worldwide Harmonized Light Vehicles Test Cycle). The study is done using a complex model developed in a performant simulation environment. Transmission efficiency calculation is emphasized, the efficiency being considered variable depending on engine torque, engine speed and gear ratio. The main important parameters (vehicle speed fluctuation, overall transmission efficiency, fuel consumption ratio) needed to compare test cycles and the transmissions performance are determined.

  9. Performance Testing Methodology for Safety-Critical Programmable Logic Controller

    International Nuclear Information System (INIS)

    Kim, Chang Ho; Oh, Do Young; Kim, Ji Hyeon; Kim, Sung Ho; Sohn, Se Do

    2009-01-01

    The Programmable Logic Controller (PLC) for use in Nuclear Power Plant safety-related applications is being developed and tested first time in Korea. This safety-related PLC is being developed with requirements of regulatory guideline and industry standards for safety system. To test that the quality of the developed PLC is sufficient to be used in safety critical system, document review and various product testings were performed over the development documents for S/W, H/W, and V/V. This paper provides the performance testing methodology and its effectiveness for PLC platform conducted by KOPEC

  10. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    We identify one potential source of bias that influences children’s performance on standardized tests and that is predictable based on psychological theory: the time at which students take the test. Using test data for all children attending Danish public schools between school years 2009....../10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus......, as the day wears on, students become increasingly fatigued and consequently more likely to underperform on a standardized test....

  11. Proficiency testing for sensory profile panels : measuring panel performance

    NARCIS (Netherlands)

    Mcewan, J.A.; Hunter, E.A.; Gemert, L.J. van; Lea, P.

    2002-01-01

    Proficiency testing in sensory analysis is an important step towards demonstrating that results from one sensory panel are consistent with the results of other sensory panels. The uniqueness of sensory analysis poses some specific problems for measuring the proficiency of the human instrument

  12. Performance Test of Parabolic Trough Solar Cooker for Indoor ...

    African Journals Online (AJOL)

    Bheema

    mm diameter copper pipe is the optimum size for the absorber. Maximum temperatures of ... This paper deals with improving and testing performance of a concentrating cooker for indoor cooking with ... bean oil Soya bean oil. Coating material.

  13. Round robin performance testing of organic photovoltaic devices

    DEFF Research Database (Denmark)

    Gevorgyan, Suren; Zubillaga, Oihana; de Seoane, José María Vega

    2014-01-01

    This study addresses the issue of poor intercomparability of measurements of organic photovoltaic (OPV) devices among different laboratories. We present a round robin performance testing of novel OPV devices among 16 laboratories, organized within the framework of European Research Infrastructure...

  14. Corrosion performance tests for reinforcing steel in concrete : technical report.

    Science.gov (United States)

    2009-10-01

    The existing test method used to assess the corrosion performance of reinforcing steel embedded in : concrete, mainly ASTM G 109, is labor intensive, time consuming, slow to provide comparative results, : and can be expensive. However, with corrosion...

  15. RELATIONSHIPS BETWEEN FUNCTIONAL MOVEMENT TESTS AND PERFORMANCE TESTS IN YOUNG ELITE MALE BASKETBALL PLAYERS.

    Science.gov (United States)

    Gonzalo-Skok, Oliver; Serna, Jorge; Rhea, Matthew R; Marín, Pedro J

    2015-10-01

    Sprinting and jumping are two common and important components of high-level sport performance. The weight-bearing dorsiflexion test (WB-DF) and Star Excursion Balance Test (SEBT) are tools developed to identify athletes at risk for lower extremity injury and may be related to running and jumping performance among athletes. The purposes of the present study were: 1) to identify any relationships between functional movement tests (WB-DF and SEBT) and performance tests (jumping, sprinting and changing direction); 2) to examine any relationships between asymmetries in functional movements and performance tests. Descriptive cohort study. Fifteen elite male basketball players (age: 15.4 ± 0.9 years) were assessed during a three-week period to determine the reliability of functional screening tools and performance tests and to examine the relationships between these tests. Relative (intraclass correlation coefficient) and absolute (coefficient of variation) reliability were used to assess the reproducibility of the tests. Significant correlations were detected between certain functional movement tests and performance tests. Both left and right excursion composite scores related to slower performance times in sprint testing, demonstrating that greater dynamic reach relates to decreased quickness and acceleration among these elite basketball athletes. The various relationships between dynamic functional movement testing, speed, and jump performance provide guidance for the strength and conditioning professional when conducting and evaluating data in an effort to improve performance and reduce risk of injury. The results of the present study suggest that these functional and performance tests do not measure the same components of human movement, and could be paired as outcome measures for the clinical and sport assessment of lower extremity function. 2b.

  16. Fracture testing and performance of beryllium copper alloy C 17510

    International Nuclear Information System (INIS)

    Murray, H.A.; Zatz, I.J.

    1992-01-01

    A series of test programs was undertaken on copper beryllium alloy C 17510 for several variations in material process and chemistry. These variations in C 17510 were primarily optimized for combinations of strength and conductivity. While originally intended for use as cyclically loaded high-field, high-strength conductors in fusion energy research, material testing of C 17510 has indicated that it is an attractive and economical alternative for a host of other structural, mechanical and electrical applications. ASTM tests performed on three variations of C 17510 alloys included both J-integral and plane strain fracture toughness testing (E813, E399) and fatigue crack growth rate tests (E647), as well as verifying tensile, hardness, Charpy, and other well defined mechanical properties. Fracture testing was performed at both room and liquid nitrogen temperatures, which bound the thermal environment anticipated for the fusion components being designed. Fatigue crack propagation stress ratios ranged from nominal zero to minus one at each temperature

  17. Development of a grinding-specific performance test set-up.

    Science.gov (United States)

    Olesen, C G; Larsen, B H; Andresen, E L; de Zee, M

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding performance.

  18. Human performance in nondestructive inspections and functional tests: Final report

    International Nuclear Information System (INIS)

    Harris, D.H.

    1988-10-01

    Human performance plays a vital role in the inspections and tests conducted to assure the physical integrity of nuclear power plants. Even when technically-sophisticated equipment is employed, the outcome is highly dependent on human control actions, calibrations, observations, analyses, and interpretations. The principal consequences of inadequate performance are missed or falsely-reported defects. However, the cost-avoidance that stems from addressing potential risks promptly, and the increasing costs likely with aging plants, emphasize that timeliness and efficiency are important inspection-performance considerations also. Human performance issues were studied in a sample of inspections and tests regularly conducted in nuclear power plants. These tasks, selected by an industry advisory panel, were: eddy-current inspection of steam-generator tubes; ultrasonic inspection of pipe welds; inservice testing of pumps and valves; and functional testing of shock suppressors. Information was obtained for the study from industry and plant procedural documents; training materials; research reports and related documents; interviews with training specialists, inspectors, supervisory personnel, and equipment designers; and first-hand observations of task performance. Eleven recommendations are developed for improving human performance on nondestructive inspections and functional tests. Two recommendations were for the more-effective application of existing knowledge; nine recommendations were for research projects that should be undertaken to assure continuing improvements in human performance on these tasks. 25 refs., 9 figs., 1 tab

  19. 42 CFR 84.103 - Man tests; performance requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests; performance requirements. 84.103 Section 84.103 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.103 Man tests;...

  20. Current Status and Performance Tests of Korea Heat Load Test Facility KoHLT-EB

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sukkwon; Jin, Hyunggon; Shin, Kyuin; Choi, Boguen; Lee, Eohwak; Yoon, Jaesung; Lee, Dongwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Duckhoi; Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    A commissioning test has been scheduled to establish the installation and preliminary performance experiments of the copper hypervapotron mockups. And a qualification test will be performed to evaluate the CuCrZr duct liner in the ITER neutral beam injection facility and the ITER first wall small-scale mockups of the semi-prototype, at up to 1.5 and 5 MW/m{sup 2} high heat flux. Also, this system will be used to test other PFCs for ITER and materials for tokamak reactors. Korean high heat flux test facility(KoHLT-EB; Korea Heat Load Test facility - Electron Beam) by using an electron beam system has been constructed in KAERI to perform the qualification test for ITER blanket FW semi-prototype mockups, hypervapotron cooling devices in fusion devices, and other ITER plasma facing components. The commissioning and performance tests with the supplier of e-gun system have been performed on November 2012. The high heat flux test for hypervapotron cooling device and calorimetry were performed to measure the surface heat flux, the temperature profile and cooling performance. Korean high heat flux test facility for the plasma facing components of nuclear fusion machines will be constructed to evaluate the performance of each component. This facility for the plasma facing materials will be equipped with an electron beam system with a 60 kV acceleration gun.

  1. Performances on Symbol Digit Modalities Test, Color Trails Test, and modified Stroop test in a healthy, elderly Danish sample

    DEFF Research Database (Denmark)

    Vogel, Asmus; Stokholm, Jette; Jørgensen, Kasper

    2013-01-01

    This study presents Danish data for the Symbol Digit Modalities Test (SDMT), Color Trails Test (CTT), and a modified Stroop test from 100 subjects aged 60-87 years. Among the included demographic variables, age had the highest impact on test performances. Thus, the study presents separate data...

  2. Performance test of a bladeless turbine for geothermal applications

    Energy Technology Data Exchange (ETDEWEB)

    Steidel, R.; Weiss, H.

    1976-03-24

    The Possell bladeless turbine was tested at the LLL Geothermal Test Facility to evaluate its potential for application in the total flow process. Test description and performance data are given for 3000, 3500, 4000, and 4500 rpm. The maximum engine efficiency observed was less than 7 percent. It is concluded that the Possell turbine is not a viable candidate machine for the conversion of geothermal fluids by the total flow process. (LBS)

  3. Preliminary results of testing bioassay analytical performance standards

    International Nuclear Information System (INIS)

    Fisher, D.R.; Robinson, A.V.; Hadley, R.T.

    1983-08-01

    The analytical performance of both in vivo and in vitro bioassay laboratories is being studied to determine the capability of these laboratories to meet the minimum criteria for accuracy and precision specified in the draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. This paper presents preliminary results of the first round of testing

  4. Effects of Vigorous Intensity Physical Activity on Mathematics Test Performance

    Science.gov (United States)

    Phillips, David S.; Hannon, James C.; Castelli, Darla M.

    2015-01-01

    The effect of an acute bout of physical activity on academic performance in school-based settings is under researched. The purpose of this study was to examine associations between a single, vigorous (70-85%) bout of physical activity completed during physical education on standardized mathematics test performance among 72, eighth grade students…

  5. Towards Smart Buildings Performance Testing as a Service

    DEFF Research Database (Denmark)

    Markoska, Elena; Lazarova-Molnar, Sanja

    2018-01-01

    Energy consumption in buildings accounts for ca. 40% of the world’s total energy consumption, yielding a call for attention to their performance and improvement of their behavior. The concept of performance testing has been developed as an approach to control, potentially lower, and bring awarene...

  6. The diagnostic odds ratio: a single indicator of test performance

    NARCIS (Netherlands)

    Glas, Afina S.; Lijmer, Jeroen G.; Prins, Martin H.; Bonsel, Gouke J.; Bossuyt, Patrick M. M.

    2003-01-01

    Diagnostic testing can be used to discriminate subjects with a target disorder from subjects without it. Several indicators of diagnostic performance have been proposed, such as sensitivity and specificity. Using paired indicators can be a disadvantage in comparing the performance of competing

  7. Performance test of a dual-purpose disc agrochemical applicator ...

    African Journals Online (AJOL)

    The performance test of a dual-purpose disc agrochemical applicator for field crop was conducted with view to assess the distribution patterns/droplet sizes and uniformity of spreading and or spraying for the agrochemical application. The equipment performances for both granular and liquid chemical application were ...

  8. Incremental exercise test performance with and without a respiratory ...

    African Journals Online (AJOL)

    Incremental exercise test performance with and without a respiratory gas collection system. ... PROMOTING ACCESS TO AFRICAN RESEARCH ... Industrial- type mask wear is thought to impair exercise performance through increased respiratory dead space, flow ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  9. [Performance of normal young adults in two temporal resolution tests].

    Science.gov (United States)

    Zaidan, Elena; Garcia, Adriana Pontin; Tedesco, Maria Lucy Fraga; Baran, Jane A

    2008-01-01

    temporal auditory processing is defined as the perception of sound or of sound alteration within a restricted time interval and is considered a fundamental ability for the auditory perception of verbal and non verbal sounds, for the perception of music, rhythm, periodicity and in the discrimination of pitch, duration and of phonemes. to compare the performance of normal Brazilian adults in two temporal resolution tests: the Gaps-in-Noise Test (GIN) and the Random Gap Detection Test (RGDT), and to analyze potential differences of performance in these two tests. twenty-five college students with normal hearing (11 males and 14 females) and no history of educational, neurological and/or language problems, underwent the GIN and RGDT at 40dB SL. statistically significant gender effects for both tests were found, with female participants showing poorer performance on both temporal processing tests. In addition, a comparative analysis of the results obtained in the GIN and RGDT revealed significant differences in the threshold measures derived for these two tests. In general, significantly better gap detection thresholds were observed for both male and female participants on the GIN test when compared to the results obtained for the RGDT. male participants presented better performances on both RGDT and GIN, when compared to the females. There were no differences in performance between right and left ears on the GIN test. Participants of the present investigation, males and females, performed better on the GIN when compared to the RGDT. The GIN presented advantages over the RGDT, not only in terms of clinical validity and sensibility, but also in terms of application and scoring.

  10. Additive and Multiplicative Effects of Working Memory and Test Anxiety on Mathematics Performance in Grade 3 Students

    Science.gov (United States)

    Korhonen, Johan; Nyroos, Mikaela; Jonsson, Bert; Eklöf, Hanna

    2018-01-01

    The aim of this study was to investigate the interplay between test anxiety and working memory (WM) on mathematics performance in younger children. A sample of 624 grade 3 students completed a test battery consisting of a test anxiety scale, WM tasks and the Swedish national examination in mathematics for grade 3. The main effects of test anxiety…

  11. Motivational deficits and cognitive test performance in schizophrenia.

    Science.gov (United States)

    Fervaha, Gagan; Zakzanis, Konstantine K; Foussias, George; Graff-Guerrero, Ariel; Agid, Ofer; Remington, Gary

    2014-09-01

    Motivational and cognitive deficits are core features of schizophrenia, both closely linked with functional outcomes. Although poor effort and decreased motivation are known to affect performance on cognitive tests, the extent of this relationship is unclear in patients with schizophrenia. To evaluate the association between intrinsic motivation and cognitive test performance in patients with schizophrenia. Cross-sectional and 6-month prospective follow-up study performed at 57 sites in the United States, including academic and community medical treatment centers, participating in the Clinical Antipsychotic Trials of Intervention Effectiveness study. The primary sample included 431 stable patients with a DSM-IV diagnosis of schizophrenia currently receiving a stable medication regimen. Cognitive performance and intrinsic motivation were evaluated using a comprehensive neuropsychological test battery and a derived measure from the Heinrichs-Carpenter Quality of Life Scale, respectively. Symptom severity and functional status were also assessed. The primary outcome variable was global neurocognition. Individual domains of cognition were also evaluated for their association with motivation. Level of intrinsic motivation was significantly and positively correlated with global cognitive test performance, a relationship that held for each domain of cognition evaluated (correlation range, 0.20-0.34; P motivation and cognitive performance also remained significant after controlling for antipsychotic dose (P motivation during the 6-month follow-up was also found to be significantly related to improvement in global cognitive performance (P motivation and cognitive performance and suggest that test performance is not purely a measure of ability. Future studies assessing cognition in patients with schizophrenia should consider potential moderating variables such as effort and motivation. Implications for the assessment and interpretation of cognitive impairment based on

  12. Report on long range alpha detector (LRAD) performance tests

    International Nuclear Information System (INIS)

    Kobayashi, Hirohide; Unno, Motoyoshi; Ishikawa, Hisashi; Yoshida, Tadayoshi

    2002-10-01

    At present, alpha contamination measurement on objects is conducted with ZnS scintillation survey meter (direct method) and smear test (indirect method). But it is difficult to measure large and complicated objects by direct method. Long Range Alpha Detector (LRAD) was produced as a solution for this problem. We carried out performance tests of this LRAD. As a result of the performance tests, we confirmed the linear relation between the measurement values of LRAD and alpha-radioactivity on the surface of objects. (author)

  13. Product consistency test and toxicity characteristic leaching procedure results of the ceramic waste form from the electrometallurgical treatment process for spent fuel

    International Nuclear Information System (INIS)

    Johnson, S. G.; Adamic, M. L.: DiSanto, T.; Warren, A. R.; Cummings, D. G.; Foulkrod, L.; Goff, K. M.

    1999-01-01

    The ceramic waste form produced from the electrometallurgical treatment of sodium bonded spent fuel from the Experimental Breeder Reactor-II was tested using two immersion tests with separate and distinct purposes. The product consistency test is used to assess the consistency of the waste forms produced and thus is an indicator of a well-controlled process. The toxicity characteristic leaching procedure is used to determine whether a substance is to be considered hazardous by the Environmental Protection Agency. The proposed high level waste repository will not be licensed to receive hazardous waste, thus any waste forms destined to be placed there cannot be of a hazardous nature as defined by the Resource Conservation and Recovery Act. Results are presented from the first four fully radioactive ceramic waste forms produced and from seven ceramic waste forms produced from cold surrogate materials. The fully radioactive waste forms are approximately 2 kg in weight and were produced with salt used to treat 100 driver subassemblies of spent fuel

  14. Testing Game-Based Performance in Team-Handball.

    Science.gov (United States)

    Wagner, Herbert; Orwat, Matthias; Hinz, Matthias; Pfusterschmied, Jürgen; Bacharach, David W; von Duvillard, Serge P; Müller, Erich

    2016-10-01

    Wagner, H, Orwat, M, Hinz, M, Pfusterschmied, J, Bacharach, DW, von Duvillard, SP, and Müller, E. Testing game-based performance in team-handball. J Strength Cond Res 30(10): 2794-2801, 2016-Team-handball is a fast paced game of defensive and offensive action that includes specific movements of jumping, passing, throwing, checking, and screening. To date and to the best of our knowledge, a game-based performance test (GBPT) for team-handball does not exist. Therefore, the aim of this study was to develop and validate such a test. Seventeen experienced team-handball players performed 2 GBPTs separated by 7 days between each test, an incremental treadmill running test, and a team-handball test game (TG) (2 × 20 minutes). Peak oxygen uptake (V[Combining Dot Above]O2peak), blood lactate concentration (BLC), heart rate (HR), sprinting time, time of offensive and defensive actions as well as running intensities, ball velocity, and jump height were measured in the game-based test. Reliability of the tests was calculated using an intraclass correlation coefficient (ICC). Additionally, we measured V[Combining Dot Above]O2peak in the incremental treadmill running test and BLC, HR, and running intensities in the team-handball TG to determine the validity of the GBPT. For the test-retest reliability, we found an ICC >0.70 for the peak BLC and HR, mean offense and defense time, as well as ball velocity that yielded an ICC >0.90 for the V[Combining Dot Above]O2peak in the GBPT. Percent walking and standing constituted 73% of total time. Moderate (18%) and high (9%) intensity running in the GBPT was similar to the team-handball TG. Our results indicated that the GBPT is a valid and reliable test to analyze team-handball performance (physiological and biomechanical variables) under conditions similar to competition.

  15. High-precision performance testing of the LHC power converters

    CERN Document Server

    Bastos, M; Dreesen, P; Fernqvist, G; Fournier, O; Hudson, G

    2007-01-01

    The magnet power converters for LHC were procured in three parts, power part, current transducers and control electronics, to enable a maximum of industrial participation in the manufacturing and still guarantee the very high precision (a few parts in 10-6) required by LHC. One consequence of this approach was several stages of system tests: factory reception tests, CERN reception tests, integration tests , short-circuit tests and commissioning on the final load in the LHC tunnel. The majority of the power converters for LHC have now been delivered, integrated into complete converter and high-precision performance testing is well advanced. This paper presents the techniques used for high-precision testing and the results obtained.

  16. Pavement Subgrade Performance Study in the Danish Road Testing Machine

    DEFF Research Database (Denmark)

    Ullidtz, Per; Ertman Larsen, Hans Jørgen

    1997-01-01

    Most existing pavement subgrade criteria are based on the AASHO Road Test, where only one material was tested and for only one climatic condition. To study the validity of these criteria and to refine the criteria a co-operative research program entitled the "International Pavement Subgrade...... Performance Study" was sponsored by the FHWA with American, Finnish and Danish partners. This paper describes the first test series which was carried out in the Danish Road Testing Machine (RTM).The first step in this program is a full scale test on an instrumented pavement in the Danish Road Testing Machine....... Pressure gauges and strain cells were installed in the upper part of the subgrade, for measuring stresses and strains in all three directions. During and after construction FWD testing was carried out to evaluate the elastic parameters of the materials. These parameters were then used with the theory...

  17. Correlation Between Screening Mammography Interpretive Performance on a Test Set and Performance in Clinical Practice.

    Science.gov (United States)

    Miglioretti, Diana L; Ichikawa, Laura; Smith, Robert A; Buist, Diana S M; Carney, Patricia A; Geller, Berta; Monsees, Barbara; Onega, Tracy; Rosenberg, Robert; Sickles, Edward A; Yankaskas, Bonnie C; Kerlikowske, Karla

    2017-10-01

    Evidence is inconsistent about whether radiologists' interpretive performance on a screening mammography test set reflects their performance in clinical practice. This study aimed to estimate the correlation between test set and clinical performance and determine if the correlation is influenced by cancer prevalence or lesion difficulty in the test set. This institutional review board-approved study randomized 83 radiologists from six Breast Cancer Surveillance Consortium registries to assess one of four test sets of 109 screening mammograms each; 48 radiologists completed a fifth test set of 110 mammograms 2 years later. Test sets differed in number of cancer cases and difficulty of lesion detection. Test set sensitivity and specificity were estimated using woman-level and breast-level recall with cancer status and expert opinion as gold standards. Clinical performance was estimated using women-level recall with cancer status as the gold standard. Spearman rank correlations between test set and clinical performance with 95% confidence intervals (CI) were estimated. For test sets with fewer cancers (N = 15) that were more difficult to detect, correlations were weak to moderate for sensitivity (woman level = 0.46, 95% CI = 0.16, 0.69; breast level = 0.35, 95% CI = 0.03, 0.61) and weak for specificity (0.24, 95% CI = 0.01, 0.45) relative to expert recall. Correlations for test sets with more cancers (N = 30) were close to 0 and not statistically significant. Correlations between screening performance on a test set and performance in clinical practice are not strong. Test set performance more accurately reflects performance in clinical practice if cancer prevalence is low and lesions are challenging to detect. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  18. Performance demonstration experience for reactor pressure vessel shell ultrasonic testing

    International Nuclear Information System (INIS)

    Zado, V.

    1998-01-01

    The most ultrasonic testing techniques used by many vendors for pressurized water reactor (PWR) examinations were based on American Society of Mechanical Engineers 'Boiler and Pressurized Vessel Code' (ASME B and PV Code) Sections XI and V. The Addenda of ASME B and PV Code Section XI, Edition 1989 introduced Appendix VIII - 'Performance Demonstration for Ultrasonic Examination Systems'. In an effort to increase confidence in performance of ultrasonic testing of the operating nuclear power plants in United States, the ultrasonic testing performance demonstration examination of reactor vessel welds is performed in accordance with Performance Demonstration Initiative (PDI) program which is based on ASME Code Section XI, Appendix VIII requirements. This article provides information regarding extensive qualification preparation works performed prior EPRI guided performance demonstration exam of reactor vessel shell welds accomplished in January 1997 for the scope of Appendix VIII, Supplements IV and VI. Additionally, an overview of the procedures based on requirements of ASME Code Section XI and V in comparison to procedure prepared for Appendix VIII examination is given and discussed. The samples of ultrasonic signals obtained from artificial flaws implanted in vessel material are presented and results of ultrasonic testing are compared to actual flaw sizes. (author)

  19. Double-shell tank integrity assessments ultrasonic test equipment performance test

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, D.C.

    1996-09-26

    A double-shell tank (DST) inspection (DSTI) system was performance tested over three months until August 1995 at Pittsburgh, Pennsylvania, completing a contract initiated in February 1993 to design, fabricate, and test an ultrasonic inspection system intended to provide ultrasonic test (UT) and visual data to determine the integrity of 28 DSTs at Hanford. The DSTs are approximately one-million-gallon underground radioactive-waste storage tanks. The test was performed in accordance with a procedure (Jensen 1995) that included requirements described in the contract specification (Pfluger 1995). This report documents the results of tests conducted to evaluate the performance of the DSTI system against the requirements of the contract specification. The test of the DSTI system also reflects the performance of qualified personnel and operating procedures.

  20. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Kelly, C. Edward; Klee, Paul M.

    1997-01-01

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted

  1. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Kelly, C.E.; Klee, P.M.

    1997-01-01

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted. copyright 1997 American Institute of Physics

  2. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Dombeck, T.; Gannon, J.; Kraushaar, P.; McInturff, A.; Savord, T.; Tool, G.

    1993-05-01

    The string test facility was constructed to provide a development test bed for the arc regions of the Superconducting Super Collider (SSC). Significant effort has been devoted to the development and testing of superconducting magnets, spools, and accelerator control systems required for the SSC. The string test facility provides the necessary environment required to evaluate the operational performance of these components as they are configured as an accelerator lens in the collider. This discussion will review the results of high current testing of the string conducted to evaluate magnet element uniformity and compatibility, the splice resistance used to connect the magnets, and system response to various quench conditions. Performance results of the spools, energy bypass systems, energy dump, and the power supply system are also discussed

  3. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Dombeck, T.; Gannon, J.; Kraushaar, P.; McInturff, A.; Savord, T.; Tool, G.

    1993-01-01

    The string test facility was constructed to provide a development test bed for the arc regions of the Superconducting Super Collider (SSC). Significant effort has been devoted to the development and testing of superconducting magnets, spools, and accelerator control systems required for the SSC. The string test facility provides the necessary environment required to evaluate the operational performance of these components as they are configured as an accelerator lens in the collider. This discussion will review the results of high current testing of the string conducted to evaluate magnet element uniformity and compatibility, the splice resistance used to connect the magnets, and system response to various quench conditions. Performance results of the spools, energy bypass systems, energy dump, and the power supply system are also discussed

  4. Test beam performance of a tracking TRD [Transition Radiation Detector] prototype

    International Nuclear Information System (INIS)

    Shank, J.T.; Whitaker, J.S.; Polychronakos, V.A.; Radeka, V.; Stephani, D.; Beker, H.; Bock, R.K.; Botlo, M.; Fabjan, C.W.; Pfennig, J.; Price, M.J.; Willis, W.J.; Akesson, T.; Chernyatin, V.; Dolgoshein, B.; Nevsky, P.; Potekhin, M.; Romanjuk, A.; Sosnovtsev, V.; Gavrilenko, I.; Muravjev, S.; Shmeleva, A.

    1990-01-01

    A Tracking Transition Radiation Detector prototype has been constructed and tested. It consists of 240 straw tubes, 4 mm in diameter, imbedded in a polyethylene block acting as the radiator. Its performance as an electron identifier as well as a tracking device for minimum ionizing particles has been determined. 2 refs., 6 figs

  5. 40 CFR 63.5719 - How do I conduct a performance test?

    Science.gov (United States)

    2010-07-01

    ..., 2F or 2G of appendix A to 40 CFR part 60, as appropriate, to measure gas volumetric flow rate. (3... analytical techniques to get an accurate measure of at least 90 percent of the total organic HAP mass... device performance test must consist of three runs and each run must last at least 1 hour. The production...

  6. Results of the First Performance Tests of the CMS Electromagnetic Calorimeter

    CERN Document Server

    Adzic, Petar; Almeida, Carlos; Almeida, Nuno; Anagnostou, Georgios; Anfreville, Marc; Anicin, Ivan; Antunovic, Zeljko; Asimidis, Asimakis; Auffray, Etiennette; Baccaro, Stefania; Barney, David; Barone, Luciano; Barrillon, Pierre; Bartoloni, Alessandro; Beauceron, Stephanie; Beaudette, Florian; Bell, Ken W; Benetta, Robert; Bercher, Michel; Beteva, B; Beuselinck, Raymond; Bhardwa, A; Biino, Cristina; Bimbot, Stephane; Bloch, Philippe; Blyth, Simon; Bonesini, Maurizio; Bordalo, Paula; Bornheim, Adolf; Bourotte, Jean; Britton, David; Brown, Robert M; Brunelière, Renaud; Busson, Philippe; Camporesi, Tiziano; Cartiglia, Nicolo; Cavallari, Francesca; Chamont, David; Chang, Paoti; Chang, You-Hao; Charlot, Claude; Chen, E Augustine; Chipaux, Rémi; Cockerill, David J A; Collard, Caroline; Combaret, Christophe; Costantini, Silvia; Da Silva, J C; Dafinei, Ioan; Daskalakis, Georgios; Davatz, Giovanna; De Min, Alberto; Deiters, Konrad; Dejardin, Marc; Della Negra, Rodolphe; Depasse, Pierre; Descamp, J; Dewhirst, Guy; Dhawan, Satish; Diemoz, Marcella; Dissertori, Günther; Dittmar, Michael; Djambazov, Lubomir; Dobrzynski, Ludwik; Drndarevic, Snezana; Dupanloup, Michel; Dzelalija, Mile; Ehlers, Jan; El-Mamouni, H; Peisert, Anna; Evangelou, Ioannis; Fabbro, Bernard; Faure, Jean-Louis; Fay, Jean; Ferri, Federico; Flower, Paul S; Franzoni, Giovanni; Funk, Wolfgang; Gaillac, Anne-Marie; Gargiulo, Corrado; Gascon-Shotkin, S; Geerebaert, Yannick; Gentit, François-Xavier; Ghezzi, Alessio; Gilly, Jean; Giolo-Nicollerat, Anne-Sylvie; Givernaud, Alain; Gninenko, Sergei; Go, Apollo; Godinovic, Nikola; Golubev, Nikolai; Gómez-Reino, Robert; Govoni, Pietro; Grahl, James; Gras, Philippe; Greenhalgh, Justin; Guillaud, Jean-Paul; Haguenauer, Maurice; Hamel De Montechenault, G; Hansen, Magnus; Heath, Helen F; Hill, Jack; Hobson, Peter R; Holmes, Daniel; Holzner, André; Hou, George Wei-Shu; Ille, Bernard; Ingram, Quentin; Jain, Adarsh; Janot, Patrick; Jarry, Patrick; Karar, M A; Kataria, Sushil Kumar; Katchanov, V A; Kennedy, Bruce W; Kloukinas, Kostas; Koblitz, Birger; Kokkas, Panagiotis; Korjik, M; Krasnikov, Nikolai; Krpic, Dragomir; Kyriakis, Aristotelis; Lebeau, Michel; Lecomte, Pierre; Lecoq, Paul; Lemaire, Marie-Claude; Lethuillier, Morgan; Lin, Willis; Lintern, A L; Lister, Alison; Locci, Elizabeth; Lodge, Anthony B; Longo, Egidio; Loukas, Demetrios; Lustermann, Werner; Lynch, Clare; MacKay, Catherine Kirsty; Maletic, Dimitrije; Mandjavidze, Irakli; Manthos, Nikolaos; Markou, Athanasios; Mathez, Hervé; Matveev, Viktor; Maurelli, Georges; Menichetti, Ezio; Meridiani, Paolo; Milenovic, Predrag; Milleret, Gérard; Miné, Philippe; Montecchi, Marco; Mur, Michel; Musienko, Yuri; Nardulli, Alessandro; Nash, Jordan; Neal, Homer; Nédélec, Patrick; Negri, Pietro; Nessi-Tedaldi, Francesca; Newman, Harvey B; Nikitenko, Alexander; Obertino, Maria Margherita; Ofierzynski, Radoslaw Adrian; Organtini, Giovanni; Paganini, Pascal; Paganoni, Marco; Papadopoulos, Ioannis; Paramatti, Riccardo; Pastrone, Nadia; Pauss, Felicitas; Poilleux, Patrick; Puljak, Ivica; Pullia, Antonino; Puzovic, Jovan; Ragazzi, Stefano; Ramos, Sergio; Rander, John; Ravat, Olivier; Raymond, M; Razis, Panos A; Redaelli, Nicola; Regnault, Nicolas; Renker, Dieter; Reucroft, Steve; Reymond, Jean-Marc; Reynaud, Michel; Reynaud, Serge; Romanteau, Thierry; Rondeaux, Françoise; Rosowsky, André; Rovelli, Chiara; Rusack, Roger; Rusakov, Sergey V; Ryan, Matthew John; Rykaczewski, Hans; Sakhelashvili, Tariel; Salerno, Roberto; Santos, Marcelino; Schinzel, Dietrich; Seez, Christopher; Semeniouk, Igor; Sempere-Roldan, P; Sharif, Omar; Sharp, Peter; Shepherd-Themistocleous, Claire; Shevchenko, Sergey; Shivpuri, Ram Krishen; Sidiropoulos, Georgios; Sillou, Daniel; Singovsky, Alexander; Sirois, Yves; Sirunyan, Albert M; Smith, Brian; Smith, Vincent J; Sproston, Martin; Suter, Henry; Swain, John; Tabarelli de Fatis, Tommaso; Takahashi, Maiko; Tapper, Robert J; Tcheremoukhine, Alexandre; Teixeira, Isabel; Teixeira, Joao Paulo; Teller, Olivier; Triantis, Frixos A; Troshin, Sergey; Tyurin, Nikolay; Udriot, Stève; Ueno, Koji; Uzunian, Andrey; Van Vulpen, Ivo; Varela, Joao; Vaz-Cardoso, N; Verrecchia, Patrice; Vichoudis, Paschalis; Viertel, Gert; Virdee, Tejinder; Wang, Minzu; Williams, Jennifer C; Yaselli, Ignacio; Zamiatin, Nikolai; Zelepoukine, Serguei; Zeller, Michael E; Zhang, Lin; Zhu, Kejun; Zhu, Ren-Yuan

    2006-01-01

    Performance tests of some aspects of the CMS ECAL were carried out on modules of the "barrel" sub-system in 2002 and 2003. A brief test with high energy electron beams was made in late 2003 to validate prototypes of the new Very Front End electronics. The final versions of the monitoring and cooling systems, and of the high and low voltage regulation were used in these tests. The results are consistent with the performance targets including those for noise and overall energy resolution, required to fulfil the physics programme of CMS at the LHC.

  7. Dynamic Performance Characteristic Tests of Real Scale Lead Rubber Bearing for the Evaluation of Performance Criteria

    International Nuclear Information System (INIS)

    Kim, Min Kyu; Kim, Jung-Han; Choi, In-Kil

    2014-01-01

    Dynamic characteristic tests of full scale lead rubber bearing were performed for the evaluation of performance criteria of isolation system for nuclear power plants. For the dynamic test for a full scale rubber bearing, two 1500mm diameter lead rubber bearings were manufactured. The viewpoints of this dynamic test are determination of an ultimate shear strain level of lead rubber bearing, behavior of rubber bearing according to static and dynamic input motion, sinusoidal and random (earthquake) motion, and 1-dimentional and 2-dimensional input motion. In this study, seismic isolation device tests were performed for the evaluation of performance criteria of isolation system. Through this test, it can be recognized that in the case of considering a mechanical property test, dynamic and multi degree of loading conditions should be determined. But these differences should be examined how much affect to the global structural behavior

  8. Play for Performance: Using Computer Games to Improve Motivation and Test-Taking Performance

    Science.gov (United States)

    Dennis, Alan R.; Bhagwatwar, Akshay; Minas, Randall K.

    2013-01-01

    The importance of testing, especially certification and high-stakes testing, has increased substantially over the past decade. Building on the "serious gaming" literature and the psychology "priming" literature, we developed a computer game designed to improve test-taking performance using psychological priming. The game primed…

  9. History of personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, C. G.

    2007-01-01

    The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11 (2001). Now in its third edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by US Nuclear Regulatory Commission (NRC) regulations. The US Dept. of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Dept. of Energy Laboratory Accreditation Program (DOELAP). A focus in recent years has been the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonisation to US personal dosemeter processing testing. Since there is no type testing program in the US for personal dosemeters, the testing philosophy of ANSI N13.11 has always combined elements of type testing and routine performance testing. This philosophy is explored in detail in this presentation, along with trends in the development of the document to its present state. In addition, a look will be taken at what the future holds for the next revision of the document, scheduled to begin in 2005. (authors)

  10. Personal dosimetry performance testing in the United States

    International Nuclear Information System (INIS)

    Soares, C.G.

    2005-01-01

    Full text: The basis for personal dosimetry performance testing in the United States is ANSI/HPS N13.11 (2002). Now in its third edition, this standard has been in place since 1983. Testing under this standard is administered by the National Voluntary Accreditation Program (NVLAP), and accreditation of dosimetry processors under this program is required by US Nuclear Regulatory Commission (NRC) regulations. The US Department of Energy (DOE) also maintains a testing program for its laboratories and contractors, administered by the Department of Energy Laboratory Accreditation Program (DOELAP). A focus in recent years has been the modification of ANSI/HPS N13.11 to allow acceptance by both testing programs in order to bring harmonization to US personal dosimeter processing testing. The testing philosophy of ANSI N13.11 has always combined elements of type testing and routine performance testing and is thus different from the testing philosophy used in the rest of the world. This unique philosophy is explored in detail in this presentation, along with trends in the development of the document to its present state. In addition, a look will be taken at what the future holds for the next revision of the document, scheduled to begin in 2005. (author)

  11. Development of a grinding-specific performance test set-up

    DEFF Research Database (Denmark)

    Olesen, C. G.; Larsen, B. H.; Andresen, E. L.

    2015-01-01

    The aim of this study was to develop a performance test set-up for America's Cup grinders. The test set-up had to mimic the on-boat grinding activity and be capable of collecting data for analysis and evaluation of grinding performance. This study included a literature-based analysis of grinding...... demands and a test protocol developed to accommodate the necessary physiological loads. This study resulted in a test protocol consisting of 10 intervals of 20 revolutions each interspersed with active resting periods of 50 s. The 20 revolutions are a combination of both forward and backward grinding...... and an exponentially rising resistance. A custom-made grinding ergometer was developed with computer-controlled resistance and capable of collecting data during the test. The data collected can be used to find measures of grinding performance such as peak power, time to complete and the decline in repeated grinding...

  12. Measurement properties of continuous text reading performance tests.

    Science.gov (United States)

    Brussee, Tamara; van Nispen, Ruth M A; van Rens, Ger H M B

    2014-11-01

    Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. A literature search was performed in PubMed, Embase and PsycInfo. Subsequently, information on design and content of reading tests, study design and measurement properties were extracted using consensus-based standards for selection of health measurement instruments. Quality of studies, reading tests and measurement properties were systematically assessed using pre-specified criteria. From 2334 identified articles, 20 relevant articles were found on measurement properties of three reading tests in various languages: IReST, MNread Reading Test and Radner Reading Charts. All three reading tests scored high on content validity. Reproducibility studies (repeated measurements between different testing sessions) of the IReST and MNread of commercially available reading tests in different languages were missing. The IReST scored best on inter-language comparison, the MNread scored well in repeatability studies (repeated measurements under the same conditions) and the Radner showed good reproducibility in studies. Although in daily practice there are other continuous text reading tests available meeting the criteria of this review, measurement properties were described in scientific studies for only three of them. Of the few available studies, the quality and content of study design and methodology used varied. For testing existing reading tests and the development of new ones, for example in other languages, we make several recommendations, including careful description of patient characteristics, use of objective and subjective lighting levels, good control of working distance, documentation of the number of raters and their training, careful documentation of scoring rules and the use of Bland-Altman analyses or similar for

  13. Fracture testing and performance of beryllium copper alloy C17510

    International Nuclear Information System (INIS)

    Murray, H.A.; Zatz, I.J.

    1994-05-01

    When a literature search and discussion with manufacturers revealed that there was virtually no existing data related to the fracture properties and behavior of copper beryllium alloy C17510, a series of test programs was undertaken to ascertain this information for several variations in material processing and chemistry. These variations in C17510 were primarily optimized for combinations of strength and conductivity. While originally intended for use as cyclically loaded high-field, high-strength conductors in fusion energy research, material testing of C17510 has indicated that it is an attractive and economical alternative for a host of other structural, mechanical and electrical applications. ASTM tests performed on three variations of C17510 alloys included both J-integral and plane strain fracture toughness testing and fatigue crack growth rate tests, as well as verifying tensile, hardness, Charpy, and other well defined mechanical properties. Fracture testing was performed at both room and liquid nitrogen temperatures, which bound the thermal environment anticipated for the fusion components being designed. Fatigue crack propagation stress ratios ranged from nominal zero to minus one at each temperature. In order to confirm the test results, duplicate and independent test programs were awarded to separate facilities with appropriate test experience, whenever possible. The primary goal of the test program, to determine and bound the fracture toughness and Paris constants for C17510,was accomplished. In addition, a wealth of information was accumulated pertaining to crack growth characteristics, effects of directionality and potential testing pitfalls. The paper discusses the test program and its findings in detail

  14. Gamma-ray shielding design and performance test of WASTEF

    International Nuclear Information System (INIS)

    Matsumoto, Seiichiro; Aoyama, Saburo; Tashiro, Shingo; Nagai, Shiro

    1984-06-01

    The Waste Safety Testing Facility (WASTEF) was planned in 1978 to test the safety performance of HLW vitrified forms under the simulated conditions of long term storage and disposal, and completed in August 1981. The designed feature of the facility is to treat the vitrified forms contain actual high-level wastes of 5 x 10 4 Ci in maximum with 5 units of concrete shilded hot cells (3 units : Bate-Gamma cells, 2 units : Alpha-Gamma cells) and one units of Alpha-Gamma lead shielded cell, and to store radioactivity of 10 6 Ci in maximum. The safety performance of this facility is fundamentally maintained with confinement of radioactivity and shielding of the radiation. This report describes the method of gamma-ray shielding design, evaluation of the shielding test performed by using sealded gamma-ray sources(Co-60). (author)

  15. Performance testing of an off-plane reflection grating and silicon pore optic spectrograph at PANTER

    Science.gov (United States)

    Marlowe, Hannah; McEntaffer, Randall L.; Allured, Ryan; DeRoo, Casey T.; Donovan, Benjamin D.; Miles, Drew M.; Tutt, James H.; Burwitz, Vadim; Menz, Benedikt; Hartner, Gisela D.; Smith, Randall K.; Cheimets, Peter; Hertz, Edward; Bookbinder, Jay A.; Günther, Ramses; Yanson, Alex; Vacanti, Giuseppe; Ackermann, Marcelo

    2015-10-01

    An x-ray spectrograph consisting of aligned, radially ruled off-plane reflection gratings and silicon pore optics (SPO) was tested at the Max Planck Institute for Extraterrestrial Physics PANTER x-ray test facility. SPO is a test module for the proposed Arcus mission, which will also feature aligned off-plane reflection gratings. This test is the first time two off-plane gratings were actively aligned to each other and with an SPO to produce an overlapped spectrum. We report the performance of the complete spectrograph utilizing the aligned gratings module and plans for future development.

  16. Light water reactor pressure isolation valve performance testing

    International Nuclear Information System (INIS)

    Neely, H.H.; Jeanmougin, N.M.; Corugedo, J.J.

    1990-07-01

    The Light Water Reactor Valve Performance Testing Program was initiated by the NRC to evaluate leakage as an indication of valve condition, provide input to Section XI of the ASME Code, evaluate emission monitoring for condition and degradation and in-service inspection techniques. Six typical check and gate valves were purchased for testing at typical plant conditions (550F at 2250 psig) for an assumed number of cycles for a 40-year plant lifetime. Tests revealed that there were variances between the test results and the present statement of the Code; however, the testing was not conclusive. The life cycle tests showed that high tech acoustic emission can be utilized to trend small leaks, that specific motor signature measurement on gate valves can trend and indicate potential failure, and that in-service inspection techniques for check valves was shown to be both feasible and an excellent preventive maintenance indicator. Life cycle testing performed here did not cause large valve leakage typical of some plant operation. Other testing is required to fully understand the implication of these results and the required program to fully implement them. (author)

  17. Radioactive material package test standards and performance requirements - public perception

    International Nuclear Information System (INIS)

    Pope, R.B.; Shappert, L.B.; Rawl, R.R.

    1992-01-01

    This paper addresses issues related to the public perception of the regulatory test standards and performance requirements for packaging and transporting radioactive material. Specifically, it addresses the adequacy of the package performance standards and testing for Type B packages, which are those packages designed for transporting the most hazardous quantities and forms of radioactive material. Type B packages are designed to withstand accident conditions in transport. To improve public perception, the public needs to better understand: (a) the regulatory standards and requirements themselves, (b) the extensive history underlying their development, and (c) the soundness of the technical foundation. The public needs to be fully informed on studies, tests, and analyses that have been carried out worldwide and form the basis of the regulatory standards and requirements. This paper provides specific information aimed at improving the public perception of packages test standards

  18. Test anxiety and academic performance in chiropractic students.

    Science.gov (United States)

    Zhang, Niu; Henderson, Charles N R

    2014-01-01

    Objective : We assessed the level of students' test anxiety, and the relationship between test anxiety and academic performance. Methods : We recruited 166 third-quarter students. The Test Anxiety Inventory (TAI) was administered to all participants. Total scores from written examinations and objective structured clinical examinations (OSCEs) were used as response variables. Results : Multiple regression analysis shows that there was a modest, but statistically significant negative correlation between TAI scores and written exam scores, but not OSCE scores. Worry and emotionality were the best predictive models for written exam scores. Mean total anxiety and emotionality scores for females were significantly higher than those for males, but not worry scores. Conclusion : Moderate-to-high test anxiety was observed in 85% of the chiropractic students examined. However, total test anxiety, as measured by the TAI score, was a very weak predictive model for written exam performance. Multiple regression analysis demonstrated that replacing total anxiety (TAI) with worry and emotionality (TAI subscales) produces a much more effective predictive model of written exam performance. Sex, age, highest current academic degree, and ethnicity contributed little additional predictive power in either regression model. Moreover, TAI scores were not found to be statistically significant predictors of physical exam skill performance, as measured by OSCEs.

  19. Large scale and performance tests of the ATLAS online software

    International Nuclear Information System (INIS)

    Alexandrov; Kotov, V.; Mineev, M.; Roumiantsev, V.; Wolters, H.; Amorim, A.; Pedro, L.; Ribeiro, A.; Badescu, E.; Caprini, M.; Burckhart-Chromek, D.; Dobson, M.; Jones, R.; Kazarov, A.; Kolos, S.; Liko, D.; Lucio, L.; Mapelli, L.; Nassiakou, M.; Schweiger, D.; Soloviev, I.; Hart, R.; Ryabov, Y.; Moneta, L.

    2001-01-01

    One of the sub-systems of the Trigger/DAQ system of the future ATLAS experiment is the Online Software system. It encompasses the functionality needed to configure, control and monitor the DAQ. Its architecture is based on a component structure described in the ATLAS Trigger/DAQ technical proposal. Regular integration tests ensure its smooth operation in test beam setups during its evolutionary development towards the final ATLAS online system. Feedback is received and returned into the development process. Studies of the system behavior have been performed on a set of up to 111 PCs on a configuration which is getting closer to the final size. Large scale and performance test of the integrated system were performed on this setup with emphasis on investigating the aspects of the inter-dependence of the components and the performance of the communication software. Of particular interest were the run control state transitions in various configurations of the run control hierarchy. For the purpose of the tests, the software from other Trigger/DAQ sub-systems has been emulated. The author presents a brief overview of the online system structure, its components and the large scale integration tests and their results

  20. Relationships Between Anaerobic Performance, Field Tests and Game Performance of Sitting Volleyball Players

    Directory of Open Access Journals (Sweden)

    Marszalek Jolanta

    2015-12-01

    Full Text Available The aim of this study was to evaluate relationships between anaerobic performance, field tests, game performance and anthropometric variables of sitting volleyball players. Twenty elite Polish sitting volleyball players were tested using the 30 s Wingate Anaerobic Test for arm crank ergometer and participated in six physical field tests. Heights in position to block and to spike, as well as arm reach were measured. Players were observed during the game on the court in terms of effectiveness of the serve, block, attack, receive and defense. Pearson analysis and the Spearman's rank correlation coefficient were used. The strongest correlations were found between the chest pass test and mean power and peak power (r=.846; p=.001 and r=.708; p=.0005, respectively, and also between the T-test and peak power (r= −.718; p=.001. Mean power correlated with the 3 m test (r= −.540; p=.014, the 5 m test (r= −.592; p=.006, and the T-test (r= −.582; p=.007. Peak power correlated with the 3 m test (r= −.632; p=.003, the 5 m test (r= −.613; p=.004, speed & agility (r= −.552; p=.012 and speed & endurance (r=−.546; p=.013. Significant correlations were observed between anthropometric parameters and anaerobic performance variables (p≤.001, and also between anthropometric parameters and field tests (p≤.05. Game performance and physical fitness of sitting volleyball players depended on their anthropometric variables: reach of arms, the position to block and to spike. The chest pass test could be used as a non-laboratory field test of anaerobic performance of sitting volleyball players.

  1. Delay model and performance testing for FPGA carry chain TDC

    International Nuclear Information System (INIS)

    Kang Xiaowen; Liu Yaqiang; Cui Junjian Yang Zhangcan; Jin Yongjie

    2011-01-01

    Time-of-flight (TOF) information would improve the performance of PET (position emission tomography). TDC design is a key technique. It proposed Carry Chain TDC Delay model. Through changing the significant delay parameter of model, paper compared the difference of TDC performance, and finally realized Time-to-Digital Convertor (TDC) based on Carry Chain Method using FPGA EP2C20Q240C8N with 69 ps LSB, max error below 2 LSB. Such result could meet the TOF demand. It also proposed a Coaxial Cable Measuring method for TDC testing, without High-precision test equipment. (authors)

  2. Power Performance Test Report for the SWIFT Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, I.; Hur, J.

    2012-12-01

    This report summarizes the results of a power performance test that NREL conducted on the SWIFT wind turbine. This test was conducted in accordance with the International Electrotechnical Commission's (IEC) standard, Wind Turbine Generator Systems Part 12: Power Performance Measurements of Electricity Producing Wind Turbines, IEC 61400-12-1 Ed.1.0, 2005-12. However, because the SWIFT is a small turbine as defined by IEC, NREL also followed Annex H that applies to small wind turbines. In these summary results, wind speed is normalized to sea-level air density.

  3. Enhancement on Wingate Anaerobic Test Performance With Hyperventilation.

    Science.gov (United States)

    Leithäuser, Renate M; Böning, Dieter; Hütler, Matthias; Beneke, Ralph

    2016-07-01

    Relatively long-lasting metabolic alkalizing procedures such as bicarbonate ingestion have potential for improving performance in long-sprint to middle-distance events. Within a few minutes, hyperventilation can induce respiratory alkalosis. However, corresponding performance effects are missing or equivocal at best. To test a potential performance-enhancing effect of respiratory alkalosis in a 30-s Wingate Anaerobic Test (WAnT). 10 men (mean ± SD age 26.6 ± 4.9 y, height 184.4 ± 6.1 cm, body-mass test 1 80.7 ± 7.7 kg, body-mass test 2 80.4 ± 7.2 kg, peak oxygen uptake 3.95 ± 0.43 L/min) performed 2 WAnTs, 1 with and 1 without a standardized 15-min hyperventilation program pre-WAnT in randomized order separated by 1 wk. Compared with the control condition, hyperventilation reduced (all P respiratory alkalosis can enhance WAnT cycling sprint performance well in the magnitude of what is seen after successful bicarbonate ingestion.

  4. Indicators of Ceriodaphnia dubia chronic toxicity test performance and sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Rosebrock, M.M.; Bedwell, N.J.; Ausley, L.W. [North Carolina Division of Environmental Management, Raleigh, NC (United States)

    1994-12-31

    The North Carolina Division of Environmental Management has begun evaluation of the sensitivity of test results used for measuring chronic whole effluent toxicity in North Carolina wastewater discharges. Approximately 67% of 565 facilities required to monitor toxicity by an NPDES permit perform a Ceriodaphnia dubia chronic, single effluent concentration (pass/fail) analysis. Data from valid Ceriodaphnia dubia chronic pass/fail tests performed by approximately 20 certified biological laboratories and submitted by North Carolina NPDES permittees were recorded beginning January 1992. Control and treatment reproduction data from over 2,500 tests submitted since 1992 were analyzed to determine the minimum significant difference (MSD) at a 99% confidence level for each test and the percent reduction from the control mean that the MSD represents (%MSD) for each certified laboratory. Initial results for the 20 laboratories indicate that the average intralaboratory percent MSD ranges 12.72% (n = 367) to 34.91% (n = 7) with an average of 23.08%. Additionally, over 3,800 tests were analyzed to determine the coefficient of variation (CV) for control reproduction for each test and the average for each certified biological laboratory. Preliminary review indicates that average interlaboratory control reproduction CV values range from 10.59% (n = 367) to 31.08% (n = 572) with a mean of 20.35%. The statistics investigated are indicators of intra/interlaboratory performance and sensitivity of Ceriodaphnia chronic toxicity analyses.

  5. Verification Test of Hydraulic Performance for Reactor Coolant Pump

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Jun; Kim, Jae Shin; Ryu, In Wan; Ko, Bok Seong; Song, Keun Myung [Samjin Ind. Co., Seoul (Korea, Republic of)

    2010-01-15

    According to this project, basic design for prototype pump and model pump of reactor coolant pump and test facilities has been completed. Basic design for prototype pump to establish structure, dimension and hydraulic performance has been completed and through primary flow analysis by computational fluid dynamics(CFD), flow characteristics and hydraulic performance have been established. This pump was designed with mixed flow pump having the following design requirements; specific velocity(Ns); 1080.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 3115m{sup 3}/h, total head ; 26.3m, pump speed; 1710rpm, pump efficiency; 77.0%, Impeller out-diameter; 349mm, motor output; 360kw, design pressure; 17MPaG. The features of the pump are leakage free due to no mechanical seal on the pump shaft which insures reactor's safety and law noise level and low vibration due to no cooling fan on the motor which makes eco-friendly product. Model pump size was reduced to 44% of prototype pump for the verification test for hydraulic performance of reactor coolant pump and was designed with mixed flow pump and canned motor having the following design requirements; specific speed(NS); 1060.9(rpm{center_dot}m{sup 3}/m{center_dot}m), capacity; 539.4m{sup 3}/h, total head; 21.0m, pump speed; 3476rpm, pump efficiency; 72.9%, Impeller out-diameter; 154mm, motor output; 55kw, design pressure; 1.0MPaG. The test facilities were designed for verification test of hydraulic performance suitable for pump performance test, homologous test, NPSH test(cavitation), cost down test and pressure pulsation test of inlet and outlet ports. Test tank was designed with testing capacity enabling up to 2000m{sup 3}/h and design pressure 1.0MPaG. Auxiliary pump was designed with centrifugal pump having capacity; 1100m{sup 3}/h, total head; 42.0m, motor output; 190kw

  6. Predictive testing of performance of metals in HTR service environments

    International Nuclear Information System (INIS)

    Kondo, T.; Shindo, M.; Tamura, M.; Tsuji, H.; Kurata, Y.; Tsukada, T.

    1982-01-01

    Status of the material testing in simulated HTGR environment is reviewed with special attention focused on the methodology of the prediction of performance in long time. Importance of controlling effective chemical potentials relations in the material-environmental interface is stressed in regard of the complex inter-dependent kinetic relation between oxidation and carbon transport. Based on the recent experimental observations, proposals are made to establish some procedures for conservative prediction of the metal performance

  7. Standardization of test conditions for gamma camera performance measurement

    International Nuclear Information System (INIS)

    Jordan, K.

    1982-02-01

    The way of measuring gamma camera performance is to use point sources or flood sources in air, often in combination with bar phantoms. This method has nothing in common with the use of a camera in clinical practice. Particularly in the case of low energy emitters, like Tc-99m, the influence of scattered radiation over the performance of cameras is very high. The IEC document 'Characteristics and test conditions of radionuclide imaging devices' is discussed

  8. Performance test of solar-assisted ejector cooling system

    KAUST Repository

    Huang, Bin-Juine

    2014-03-01

    A solar-assisted ejector cooling/heating system (SACH-2k) is built and test result is reported. The solar-driven ejector cooling system (ECS) is connected in series with an inverter-type air conditioner (IAC). Several advanced technologies are developed in SACH-k2, including generator liquid level control in ECS, the ECS evaporator temperature control, and optimal control of fan power in cooling tower of ECS. From the field test results, the generator liquid level control performs quite well and keeps stable performance of ejector. The ECS evaporator temperature control also performs satisfactorily to keep ejector performance normally under low or fluctuating solar radiation. The fan power control system cooling tower performs stably and reduces the power consumption dramatically without affecting the ECS performance. The test results show that the overall system COPo including power consumptions of peripheral increases from 2.94-3.3 (IAC alone) to 4.06-4.5 (SACH-k2), about 33-43%. The highest COPo is 4.5. © 2013 Elsevier Ltd and IIR. All rights reserved.

  9. A Microelectrode Array with Reproducible Performance Shows Loss of Consistency Following Functionalization with a Self-Assembled 6-Mercapto-1-hexanol Layer

    Directory of Open Access Journals (Sweden)

    Damion K. Corrigan

    2018-06-01

    Full Text Available For analytical applications involving label-free biosensors and multiple measurements, i.e., across an electrode array, it is essential to develop complete sensor systems capable of functionalization and of producing highly consistent responses. To achieve this, a multi-microelectrode device bearing twenty-four equivalent 50 µm diameter Pt disc microelectrodes was designed in an integrated 3-electrode system configuration and then fabricated. Cyclic voltammetry and electrochemical impedance spectroscopy were used for initial electrochemical characterization of the individual working electrodes. These confirmed the expected consistency of performance with a high degree of measurement reproducibility for each microelectrode across the array. With the aim of assessing the potential for production of an enhanced multi-electrode sensor for biomedical use, the working electrodes were then functionalized with 6-mercapto-1-hexanol (MCH. This is a well-known and commonly employed surface modification process, which involves the same principles of thiol attachment chemistry and self-assembled monolayer (SAM formation commonly employed in the functionalization of electrodes and the formation of biosensors. Following this SAM formation, the reproducibility of the observed electrochemical signal between electrodes was seen to decrease markedly, compromising the ability to achieve consistent analytical measurements from the sensor array following this relatively simple and well-established surface modification. To successfully and consistently functionalize the sensors, it was necessary to dilute the constituent molecules by a factor of ten thousand to support adequate SAM formation on microelectrodes. The use of this multi-electrode device therefore demonstrates in a high throughput manner irreproducibility in the SAM formation process at the higher concentration, even though these electrodes are apparently functionalized simultaneously in the same film

  10. Effort, symptom validity testing, performance validity testing and traumatic brain injury.

    Science.gov (United States)

    Bigler, Erin D

    2014-01-01

    To understand the neurocognitive effects of brain injury, valid neuropsychological test findings are paramount. This review examines the research on what has been referred to a symptom validity testing (SVT). Above a designated cut-score signifies a 'passing' SVT performance which is likely the best indicator of valid neuropsychological test findings. Likewise, substantially below cut-point performance that nears chance or is at chance signifies invalid test performance. Significantly below chance is the sine qua non neuropsychological indicator for malingering. However, the interpretative problems with SVT performance below the cut-point yet far above chance are substantial, as pointed out in this review. This intermediate, border-zone performance on SVT measures is where substantial interpretative challenges exist. Case studies are used to highlight the many areas where additional research is needed. Historical perspectives are reviewed along with the neurobiology of effort. Reasons why performance validity testing (PVT) may be better than the SVT term are reviewed. Advances in neuroimaging techniques may be key in better understanding the meaning of border zone SVT failure. The review demonstrates the problems with rigidity in interpretation with established cut-scores. A better understanding of how certain types of neurological, neuropsychiatric and/or even test conditions may affect SVT performance is needed.

  11. Performance Tests of a Mechanical Pump in Sodium Environment

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Kim, Byeongyeon; Cho, Youngil; Jung, Min-Hwan; Gam, Da-Young; Lee, Yong Bum; Jeong, Ji-Young; Kim, Jong-Bum [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Water is often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Nevertheless, to ensure the performance, safety, and operability of major components before its installation in the SFR, a series of demonstration experiments of some components in sodium environment should be positively necessary. So, SFR NSSS System Design Division of Korea Atomic Energy Research Institute (KAERI) built various sodium experimental facilities, especially STELLA-1 in 2012. STELLA-1 (Sodium inTegral Effect test Loop for safety simuLation and Assessment) is a large-scale separated effect test facility for demonstrating the thermal-hydraulic performances of major components such as a Sodium-to-Sodium heat exchanger (DHX), Sodium-to-Air heat exchanger (AHX) of the decay heat removal system, and mechanical sodium pump of the primary heat transport system (PHTS). The mechanical pump in-sodium performance test was successfully performed with good reproducibility of the experiment and data to compare hydraulic characteristic of a mechanical pump in-water was collected. In effect of temperature variation on the pump pressure head, reduction of pump pressure head at 250℃ by 0.57% of that of 300℃ maybe the result of an increase in sodium viscosity by 13.6% according to operating temperature decrease by 50℃. Also, we confirmed that the more flywheel weight, the longer halving time and the more initial flow rate when the pump seized, the shorter halving time. The results of the mechanical pump performance test data in sodium environment will be used to compare with that of the in water environment after the evaluation of measurement uncertainty for tests.

  12. Fluid flow measurements of Test Series A and B for the Small Scale Seal Performance Tests

    International Nuclear Information System (INIS)

    Peterson, E.W.; Lagus, P.L.; Lie, K.

    1987-12-01

    The degree of waste isolation achieved by a repository seal system is dependent upon the fluid flow characteristics, or permeability, of the seals. In order to obtain meaningful, site-specific data on the performance of various possible seal system components, a series of in situ experiments called the Small Scale Seal Performance Tests (SSSPT) are being conducted at the Waste Isolation Pilot Plant (WIPP). This report contains the results of gas flow, tracer penetration, and brine flow tests conducted on concrete seals in vertical (Test Series A) and horizontal (Test Series B) configurations. The test objectives were to evaluate the seal performance and to determine if there existed scaling effects which could influence future SSSPT designs. 3 refs., 77 figs

  13. Eurados trial performance test for neutron personal dosimetry

    DEFF Research Database (Denmark)

    Bordy, J.M.; Stadtmann, H.; Ambrosi, P.

    2001-01-01

    This paper reports on the results of a neutron trial performance test sponsored by the European Commission and organised by EURADOS. As anticipated, neutron dosimetry results were very dependent on the dosemeter type and the dose calculation algorithm. Fast neutron fields were generally well...

  14. Effective Rating Scale Development for Speaking Tests: Performance Decision Trees

    Science.gov (United States)

    Fulcher, Glenn; Davidson, Fred; Kemp, Jenny

    2011-01-01

    Rating scale design and development for testing speaking is generally conducted using one of two approaches: the measurement-driven approach or the performance data-driven approach. The measurement-driven approach prioritizes the ordering of descriptors onto a single scale. Meaning is derived from the scaling methodology and the agreement of…

  15. Fuel performance analysis for the HAMP-1 mini plate test

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Byoung Jin; Tahka, Y. W.; Yim, J. S.; Lee, B. H. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    U-7wt%Mo/Al- 5wt%Si dispersion fuel with 8gU/cm{sup 3} is chosen to achieve more efficiency and higher performance than the conventional U{sub 3}Si{sub 2} fuel. As part of the fuel qualification program for the KiJang research reactor (KJRR), three irradiation tests with mini-plates are on the way at the High-flux Advanced Neutron Application Reactor (HANARO). The first test among three HANARO Mini-Plate Irradiation tests (HAMP-1, 2, 3) has completed. PLATE code has been initially developed to analyze the thermal performance of high density U-Mo/Al dispersion fuel plates during irradiation [1]. We upgraded the PLATE code with the latest irradiation results which were implemented by corrosion, thermal conductivity and swelling model. Fuel performance analysis for HAMP-1 was conducted with updated PLATE. This paper presents results of performance evaluation of the HAMP-1. Maximum fuel temperature was obtained 136 .deg., which is far below the preset limit of 200 .deg. for the irradiation test. The meat swelling and corrosion thickness was also confirmed that the developed fuel would behave as anticipated.

  16. 40 CFR 60.58b - Compliance and performance testing.

    Science.gov (United States)

    2010-07-01

    ... accuracy requirement). (5) The quality assurance procedures of appendix F of this part except for section 5.1.1 (relative accuracy test audit) shall apply to the monitor. (6) If carbon dioxide is selected for... related activities for the purpose of improving facility performance or advancing the state-of-the-art for...

  17. Honeywell Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Sargusingh, Miriam

    2014-01-01

    The ability to recover and purify water through physiochemical processes is crucial for realizing long-term human space missions, including both planetary habitation and space travel. Because of their robust nature, distillation systems have been actively pursued as one of the technologies for water recovery. The Cascade Distillation System (CDS) is a vacuum rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. The CDS was previously under development through Honeywell and NASA. In 2009, an assessment was performed to collect data to support down-selection and development of a primary distillation technology for application in a lunar outpost water recovery system. Based on the results of this testing, an expert panel concluded that the CDS showed adequate development maturity, TRL-4, together with the best product water quality and competitive weight and power estimates to warrant further development. The Advanced Exploration Systems (AES) Water Recovery Project (WRP) worked to address weaknesses identified by The Panel; namely bearing design and heat pump power efficiency. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades. The CDS will also have been challenged with ISS analog waste streams and a subset of those being considered for Exploration architectures. This paper details interim results of the AES WRP CDS performance testing.

  18. Performance test of solar-assisted ejector cooling system

    KAUST Repository

    Huang, Bin-Juine; Ton, Wei-Zhe; Wu, Chen-Chun; Ko, Hua-Wei; Chang, Hsien-Shun; Hsu, Hang-Yuen; Liu, Jen-Hao; Wu, Jia-Hung; Yen, Rue-Her

    2014-01-01

    are developed in SACH-k2, including generator liquid level control in ECS, the ECS evaporator temperature control, and optimal control of fan power in cooling tower of ECS. From the field test results, the generator liquid level control performs quite well

  19. WhalePower tubercle blade power performance test report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-15

    Toronto-based WhalePower Corporation has developed turbine blades that are modeled after humpback whale flippers. The blades, which incorporate tubercles along the leading edge of the blade, have been fitted to a Wenvor 25 kW turbine installed in North Cape, Prince Edward Island at a test site for the Wind Energy Institute of Canada (WEICan). A test was conducted to characterize the power performance of the prototype wind turbine. This report described the wind turbine configuration with particular reference to turbine information, power rating, blade information, tower information, control systems and grid connections. The test site was also described along with test equipment and measurement procedures. Information regarding power output as a function of wind speed was included along with power curves, power coefficient and annual energy production. The results for the power curve and annual energy production contain a level of uncertainty. While measurements for this test were collected and analyzed in accordance with International Electrotechnical Commission (IEC) standards for performance measurements of electricity producing wind turbines (IEC 61400-12-1), the comparative performance data between the prototype WhalePower wind turbine blade and the Wenvor standard blade was not gathered to IEC data standards. Deviations from IEC-61400-12-1 procedures were listed. 6 tabs., 16 figs., 3 appendices.

  20. Modelling of LOCA Tests with the BISON Fuel Performance Code

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, Richard L [Idaho National Laboratory; Pastore, Giovanni [Idaho National Laboratory; Novascone, Stephen Rhead [Idaho National Laboratory; Spencer, Benjamin Whiting [Idaho National Laboratory; Hales, Jason Dean [Idaho National Laboratory

    2016-05-01

    BISON is a modern finite-element based, multidimensional nuclear fuel performance code that is under development at Idaho National Laboratory (USA). Recent advances of BISON include the extension of the code to the analysis of LWR fuel rod behaviour during loss-of-coolant accidents (LOCAs). In this work, BISON models for the phenomena relevant to LWR cladding behaviour during LOCAs are described, followed by presentation of code results for the simulation of LOCA tests. Analysed experiments include separate effects tests of cladding ballooning and burst, as well as the Halden IFA-650.2 fuel rod test. Two-dimensional modelling of the experiments is performed, and calculations are compared to available experimental data. Comparisons include cladding burst pressure and temperature in separate effects tests, as well as the evolution of fuel rod inner pressure during ballooning and time to cladding burst. Furthermore, BISON three-dimensional simulations of separate effects tests are performed, which demonstrate the capability to reproduce the effect of azimuthal temperature variations in the cladding. The work has been carried out in the frame of the collaboration between Idaho National Laboratory and Halden Reactor Project, and the IAEA Coordinated Research Project FUMAC.

  1. Post-test analysis for the APR1400 LBLOCA DVI performance test using MARS

    International Nuclear Information System (INIS)

    Bae, Kyoo Hwan; Lee, Y. J.; Kim, H. C.; Bae, Y. Y.; Park, J. K.; Lee, W.

    2002-03-01

    Post-test analyses using a multi-dimensional best-estimate analysis code, MARS, are performed for the APR1400 LBLOCA DVI (Direct Vessel Injection) performance tests. This report describes the code evaluation results for the test data of various void height tests and direct bypass tests that have been performed at MIDAS test facility. MIDAS is a scaled test facility of APR1400 with the objective of identifying multi-dimensional thermal-hydraulic phenomena in the downcomer during the reflood conditions of a large break LOCA. A modified linear scale ratio was applied in its construction and test conditions. The major thermal-hydraulic parameters such as ECC bypass fraction, steam condensation fraction, and temperature distributions in downcomer are compared and evaluated. The evaluation results of MARS code for the various test cases show that: (a) MARS code has an advanced modeling capability of well predicting major multi-dimensional thermal-hydraulic phenomena occurring in the downcomer, (b) MARS code under-predicts the steam condensation rates, which in turn causes to over-predict the ECC bypass rates. However, the trend of decrease in steam condensation rate and increase in ECC bypass rate in accordance with the increase in steam flow rate, and the calculation results of the ECC bypass rates under the EM analysis conditions generally agree with the test data

  2. Nonlinear relationship between the Product Consistency Test (PCT) response and the Al/B ratio in a soda-lime aluminoborosilicate glass

    Energy Technology Data Exchange (ETDEWEB)

    Farooqi, Rahmat Ullah, E-mail: rufarooqi@postech.ac.kr [Division of Advanced Nuclear Engineering, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang, Gyeongbuk 790-784 (Korea, Republic of); Hrma, Pavel [Division of Advanced Nuclear Engineering, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang, Gyeongbuk 790-784 (Korea, Republic of); Pacific Northwest National Laboratory, Richland, WA (United States)

    2016-06-15

    We have investigated the effect of Al/B ratio on the Product Consistency Test (PCT) response. In an aluminoborosilicate soda-lime glass based on a modified International Simple Glass, ISG-3, the Al/B ratio varied from 0 to 0.55 (in mole fractions). In agreement with various models of the PCT response as a function of glass composition, we observed a monotonic increase of B and Na releases with decreasing Al/B mole ratio, but only when the ratio was higher than 0.05. Below this value (Al/B < 0.05), we observed a sharp decrease that we attribute to B in tetrahedral coordination.

  3. SP-100 Fuel Pin Performance: Results from Irradiation Testing

    Science.gov (United States)

    Makenas, Bruce J.; Paxton, Dean M.; Vaidyanathan, Swaminathan; Marietta, Martin; Hoth, Carl W.

    1994-07-01

    A total of 86 experimental fuel pins with various fuel, liner, and cladding candidate materials have been irradiated in the Experimental Breeder Reactor-II (EBR-II) and the Fast Flux Test Facility (FFTF) reactor as part of the SP-100 fuel pin irradiation testing program. Postirradiation examination results from these fuel pins are key in establishing performance correlations and demonstrating the lifetime and safety of the reactor fuel system. This paper provides a brief description of the in-reactor fuel pin tests and presents the most recent irradiation data on the performance of wrought rhenium (Re) liner material and high density UN fuel at goal burnup of 6 atom percent (at. %). It also provides an overview of the significant variety of other fuel/liner/cladding combinations which were irradiated as part of this program and which may be of interest to more advanced efforts.

  4. Internal consistency, test-retest reliability and measurement error of the self-report version of the social skills rating system in a sample of Australian adolescents.

    Directory of Open Access Journals (Sweden)

    Sharmila Vaz

    Full Text Available The social skills rating system (SSRS is used to assess social skills and competence in children and adolescents. While its characteristics based on United States samples (US are published, corresponding Australian figures are unavailable. Using a 4-week retest design, we examined the internal consistency, retest reliability and measurement error (ME of the SSRS secondary student form (SSF in a sample of Year 7 students (N = 187, from five randomly selected public schools in Perth, western Australia. Internal consistency (IC of the total scale and most subscale scores (except empathy on the frequency rating scale was adequate to permit independent use. On the importance rating scale, most IC estimates for girls fell below the benchmark. Test-retest estimates of the total scale and subscales were insufficient to permit reliable use. ME of the total scale score (frequency rating for boys was equivalent to the US estimate, while that for girls was lower than the US error. ME of the total scale score (importance rating was larger than the error using the frequency rating scale. The study finding supports the idea of using multiple informants (e.g. teacher and parent reports, not just student as recommended in the manual. Future research needs to substantiate the clinical meaningfulness of the MEs calculated in this study by corroborating them against the respective Minimum Clinically Important Difference (MCID.

  5. Internal consistency, test-retest reliability and measurement error of the self-report version of the social skills rating system in a sample of Australian adolescents.

    Science.gov (United States)

    Vaz, Sharmila; Parsons, Richard; Passmore, Anne Elizabeth; Andreou, Pantelis; Falkmer, Torbjörn

    2013-01-01

    The social skills rating system (SSRS) is used to assess social skills and competence in children and adolescents. While its characteristics based on United States samples (US) are published, corresponding Australian figures are unavailable. Using a 4-week retest design, we examined the internal consistency, retest reliability and measurement error (ME) of the SSRS secondary student form (SSF) in a sample of Year 7 students (N = 187), from five randomly selected public schools in Perth, western Australia. Internal consistency (IC) of the total scale and most subscale scores (except empathy) on the frequency rating scale was adequate to permit independent use. On the importance rating scale, most IC estimates for girls fell below the benchmark. Test-retest estimates of the total scale and subscales were insufficient to permit reliable use. ME of the total scale score (frequency rating) for boys was equivalent to the US estimate, while that for girls was lower than the US error. ME of the total scale score (importance rating) was larger than the error using the frequency rating scale. The study finding supports the idea of using multiple informants (e.g. teacher and parent reports), not just student as recommended in the manual. Future research needs to substantiate the clinical meaningfulness of the MEs calculated in this study by corroborating them against the respective Minimum Clinically Important Difference (MCID).

  6. A review of culturally adapted versions of the Oswestry Disability Index: the adaptation process, construct validity, test-retest reliability and internal consistency.

    Science.gov (United States)

    Sheahan, Peter J; Nelson-Wong, Erika J; Fischer, Steven L

    2015-01-01

    The Oswestry Disability Index (ODI) is a self-report-based outcome measure used to quantify the extent of disability related to low back pain (LBP), a substantial contributor to workplace absenteeism. The ODI tool has been adapted for use by patients in several non-English speaking nations. It is unclear, however, if these adapted versions of the ODI are as credible as the original ODI developed for English-speaking nations. The objective of this study was to conduct a review of the literature to identify culturally adapted versions of the ODI and to report on the adaptation process, construct validity, test-retest reliability and internal consistency of these ODIs. Following a pragmatic review process, data were extracted from each study with regard to these four outcomes. While most studies applied adaptation processes in accordance with best-practice guidelines, there were some deviations. However, all studies reported high-quality psychometric properties: group mean construct validity was 0.734 ± 0.094 (indicated via a correlation coefficient), test-retest reliability was 0.937 ± 0.032 (indicated via an intraclass correlation coefficient) and internal consistency was 0.876 ± 0.047 (indicated via Cronbach's alpha). Researchers can be confident when using any of these culturally adapted ODIs, or when comparing and contrasting results between cultures where these versions were employed. Implications for Rehabilitation Low back pain is the second leading cause of disability in the world, behind only cancer. The Oswestry Disability Index (ODI) has been developed as a self-report outcome measure of low back pain for administration to patients. An understanding of the various cross-cultural adaptations of the ODI is important for more concerted multi-national research efforts. This review examines 16 cross-cultural adaptations of the ODI and should inform the work of health care and rehabilitation professionals.

  7. CASTOR-V/21 PWR spent fuel storage cask performance test

    International Nuclear Information System (INIS)

    Creer, J.M.; Schoonen, D.H.

    1986-01-01

    Performance testing of a CASTOR-V/21 PWR spent fuel storage cask manufactured by Gesellschaft fur Nuklear Service (GNS) was performed as part of a cooperative program between Virginia Power and the US Department of Energy. The performance test consisted of obtaining cask handling experience and heat transfer, shielding, and limited fuel integrity data. Five heat transfer test runs were performed with 21 Surry reactor spent fuel assemblies generating approximately 28 kW. Test runs were performed with vacuum, nitrogen, and helium backfills in both vertical and horizontal orientations. Cask exterior surface gamma and neutron dose rates were measured with the cask fully loaded. Gas samples were obtained at the beginning and end of each run with nitrogen or helium backfills to verify fuel integrity. The heat transfer performance of the CASTOR-V/21 cask was exceptionally good. Peak clad temperatures with helium and nitrogen backfills in a vertical orientation and with helium in a horizontal orientation were less than 380 0 C. Vertical vacuum and horizontal nitrogen runs resulted in peak clad temperatures over 380 0 , but the temperatures were not excessively high ( 0 C). The shielding performance of the cask met the design expectation of less than 200 mrem/h. Cask surface dose rates of <75 mrem/h can easily be established with minor gamma shielding design refinements if desired. Gas samples obtained during testing indicated no leaking fuel rods were present in the cask. It was concluded that the cask performed satisfactorily from heat transfer and shielding perspectives

  8. Walk test and school performance in mouth-breathing children.

    Science.gov (United States)

    Boas, Ana Paula Dias Vilas; Marson, Fernando Augusto de Lima; Ribeiro, Maria Angela Gonçalves de Oliveira; Sakano, Eulália; Conti, Patricia Blau Margosian; Toro, Adyléia Dalbo Contrera; Ribeiro, José Dirceu

    2013-01-01

    In recent decades, many studies on mouth breathing (MB) have been published; however, little is known about many aspects of this syndrome, including severity, impact on physical and academic performances. Compare the physical performance in a six minutes walk test (6MWT) and the academic performance of MB and nasal-breathing (NB) children and adolescents. This is a descriptive, cross-sectional, and prospective study with MB and NB children submitted to the 6MWT and scholar performance assessment. We included 156 children, 87 girls (60 NB and 27 MB) and 69 boys (44 NB and 25 MB). Variables were analyzed during the 6MWT: heart rate (HR), respiratory rate, oxygen saturation, distance walked in six minutes and modified Borg scale. All the variables studied were statistically different between groups NB and MB, with the exception of school performance and HR in 6MWT. MB affects physical performance and not the academic performance, we noticed a changed pattern in the 6MWT in the MB group. Since the MBs in our study were classified as non-severe, other studies comparing the academic performance variables and 6MWT are needed to better understand the process of physical and academic performances in MB children.

  9. Standardization of test conditions for gamma camera performance measurement

    International Nuclear Information System (INIS)

    Jordan, K.

    1980-01-01

    The actual way of measuring gamma camera performance is to use point sources or flood sources in air, often in combination with bar phantoms. This method mostly brings best performance parameters for cameras but it has nothing in common with the use of a camera in clinical practice. Particular in the case of low energy emitters, like Tc-99m, the influence of scattered radiation over the performance of cameras is very high. Therefore it is important to have test conditions of radionuclide imaging devices, that will approach as best as practicable the measuring conditions in clinical applications. It is therefore a good news that the International Electrochemical Commission IEC has prepared a draft 'Characteristics and test conditions of radionuclide imaging devices' which is now submitted to the national committees for formal approval under the Six Months' Rule. Some essential points of this document are discussed in the paper. (orig.) [de

  10. Clock Face Drawing Test Performance in Children with ADHD

    Directory of Open Access Journals (Sweden)

    Ahmad Ghanizadeh

    2013-01-01

    Full Text Available  Introduction: The utility and discriminatory pattern of the clock face drawing test in ADHD is unclear. This study therefore compared Clock Face Drawing test performance in children with ADHD and controls.   Material & methods: 95 children with ADHD and 191 school children were matched for gender ratio and age. ADHD symptoms severities were assessed using DSM-IV ADHD checklist and their intellectual functioning was assessed. The participants completed three clock-drawing tasks, and the following four functions were assessed: Contour score, Numbers score, Hands setting score, and Center score    Results: All the subscales scores of the three clock drawing tests of the ADHD group were lower than that of the control group. In ADHD children, inattention and hyperactivity/impulsivity scores were not related with free drawn clock test scores. When pre-drawn contour test was performed, inattentiveness score was statistically associated with Number score. None of the other variables of age, gender, intellectual functioning, and hand use preference were associated with Numbers score. In pre-drawn clock, no association of ADHD symptoms with any CDT subscales was significant. In addition, more errors are observed with free drawn clock and Pre-drawn contour than pre-drawn clock.    Conclusion: Putting Numbers and Hands setting are more sensitive measures to screen ADHD than Contour and Center drawing. Test performance, except Hands setting, may have already reached a developmental plateau. It is probable that Hand setting deficit in children with ADHD may not decrease from age 8 to 14 years. Performance of children with ADHD is associated with the complexity of CDT.

  11. Clock face drawing test performance in children with ADHD.

    Science.gov (United States)

    Ghanizadeh, Ahmad; Safavi, Salar; Berk, Michael

    2013-01-01

    The utility and discriminatory pattern of the clock face drawing test in ADHD is unclear. This study therefore compared Clock Face Drawing test performance in children with ADHD and controls. 95 school children with ADHD and 191 other children were matched for gender ratio and age. ADHD symptoms severities were assessed using DSM-IV ADHD checklist and their intellectual functioning was assessed. The participants completed three clock-drawing tasks, and the following four functions were assessed: Contour score, Numbers score, Hands setting score, and Center score. All the subscales scores of the three clock drawing tests of the ADHD group were lower than that of the control group. In ADHD children, inattention and hyperactivity/ impulsivity scores were not related to free drawn clock test scores. When pre-drawn contour test was performed, inattentiveness score was statistically associated with Number score while none of the other variables of age, gender, intellectual functioning, and hand use preference were associated with that kind of score. In pre-drawn clock, no association of ADHD symptoms with any CDT subscales found significant. In addition, more errors are observed with free drawn clock and Pre-drawn contour than pre-drawn clock. Putting Numbers and Hands setting are more sensitive measures to screen ADHD than Contour and Center drawing. Test performance, except Hands setting, may have already reached a developmental plateau. It is probable that Hand setting deficit in children with ADHD may not decrease from age 8 to 14 years. Performance of children with ADHD is associated with complexity of CDT.

  12. A test to evaluate the physical impact on technical performance in soccer

    DEFF Research Database (Denmark)

    Rostgaard, Thomas; Iaia, F. Marcello; Simonsen, Dennis S.

    2008-01-01

    The aim of the study was to develop and examine a test for evaluation of the physical and technical capacity of soccer players. Fourteen youth elite (YE) and seven sub-elite (SE) players performed a physical and technical test (PT-test) consisting of 10 long kicks interspersed with intense......(-1), and 76 +/- 11 umol L(-1) at the end of the test, respectively. After the test muscle CP, glycogen and lactate was 52.9 +/- 6.6, 354 +/- 39, and 25.3 +/- 5.9 mmol kg(-1) d.w., respectively. In summary, the PT-test can be used to evaluate a soccer player's technical skills under conditions similar...... intermittent exercise. In addition, a control test (CON-test) without intense exercise was performed. In both cases, the test result was evaluated by the precision of the 10 kicks. The players also performed the Yo-Yo intermittent recovery test level 2 (Yo-Yo IR2). For the SE-players, blood samples were...

  13. Raven's Test Performance of Sub-Saharan Africans: Average Performance, Psychometric Properties, and the Flynn Effect

    Science.gov (United States)

    Wicherts, Jelte M.; Dolan, Conor V.; Carlson, Jerry S.; van der Maas, Han L. J.

    2010-01-01

    This paper presents a systematic review of published data on the performance of sub-Saharan Africans on Raven's Progressive Matrices. The specific goals were to estimate the average level of performance, to study the Flynn Effect in African samples, and to examine the psychometric meaning of Raven's test scores as measures of general intelligence.…

  14. Performance testing of supercapacitors: Important issues and uncertainties

    Science.gov (United States)

    Zhao, Jingyuan; Gao, Yinghan; Burke, Andrew F.

    2017-09-01

    Supercapacitors are a promising technology for high power energy storage, which have been used in some industrial and vehicles applications. Hence, it is important that information concerning the performance of supercapacitors be detailed and reliable so system designers can make rational decisions regarding the selection of the energy storage components. This paper is concerned with important issues and uncertainties regarding the performance testing of supercapacitors. The effect of different test procedures on the measured characteristics of both commercial and prototype supercapacitors including hybrid supercapacitors have been studied. It was found that the test procedure has a relatively minor effect on the capacitance of carbon/carbon devices and a more significant effect on the capacitance of hybrid supercapacitors. The device characteristic with the greatest uncertainty is the resistance and subsequently the claimed power capability of the device. The energy density should be measured by performing constant power discharges between appropriate voltage limits. This is particularly important in the case of hybrid supercapacitors for which the energy density is rate dependent and the simple relationship E = ½CV2 does not yield accurate estimates of the energy stored. In general, most of the important issues for testing carbon/carbon devices become more serious for hybrid supercapacitors.

  15. Performance test of a ceramic turbo-viscous pump

    International Nuclear Information System (INIS)

    Abe, Tetsuya; Hiroki, Seiji; Murakami, Yoshio; Shiraishi, Shigeyuki; Totoura, Sadayuki; Ohtaki, Takashi.

    1994-01-01

    In the special fields of nuclear fusion facilities and semiconductor production installation, the development of new vacuum pumps which can cope with strong magnetic fields, high temperature gas and corrosive gas is demanded. Mitsubishi Heavy Industries Ltd. has advanced the development of ceramic turbo-molecular pumps and ceramic turbo-viscous pumps, which use ceramic rotors and gas bearings since 1985. The evaluation test of the ceramic turbo-viscous vacuum pump CT-3000H which can evacuate from atmospheric pressure to high vacuum with one pump was carried out, and the experimental results on the performance and the reliability were obtained, therefore, those are reported in this paper. The structure, specification and features of the CT-3000H are shown. The exhaust performance test of the pump was carried out in conformity with the standard of the Vacuum Society of Japan, JVIS 005 'Method of performance test for turbo-molecular pumps'. The gases used were nitrogen and helium. The results are shown. The exhaust test from atmospheric pressure was carried out by two methods, and the results are shown. (K.I.)

  16. Multiphase pumping: indoor performance test and oilfield application

    Science.gov (United States)

    Kong, Xiangling; Zhu, Hongwu; Zhang, Shousen; Li, Jifeng

    2010-03-01

    Multiphase pumping is essentially a means of adding energy to the unprocessed effluent which enables the liquid and gas mixture to be transported over a long distances without prior separation. A reduction, consolidation, or elimination of the production infrastructure, such as separation equipments and offshore platforms can be developed more economically. Also it successfully lowed the backpressure of wells, revived dead wells and improved the production and efficiency of oilfield. This paper reviews the issues related to indoor performance test and an oilfield application of the helico-axial multiphase pump designed by China University of Petroleum (Beijing). Pump specification and its hydraulic design are given. Results of performance testing under different condition, such as operational speed and gas volume fraction (GVF) etc are presented. Experimental studies on combination of theoretical analysis showed the multiphase pump satisfies the similitude rule, which can be used in the development of new MPP design and performance prediction. Test results showed that rising the rotation speed and suction pressure could better its performance, pressure boost improved, high efficiency zone expanding and the flow rate related to the optimum working condition increased. The pump worked unstable as GVF increased to a certain extent and slip occurred between two phases in the pump, creating surging and gas lock at a high GVF. A case of application in Nanyang oilfield is also studied.

  17. Hydrogen Field Test Standard: Laboratory and Field Performance

    Science.gov (United States)

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are

  18. Wafer-level radiometric performance testing of uncooled microbolometer arrays

    Science.gov (United States)

    Dufour, Denis G.; Topart, Patrice; Tremblay, Bruno; Julien, Christian; Martin, Louis; Vachon, Carl

    2014-03-01

    A turn-key semi-automated test system was constructed to perform on-wafer testing of microbolometer arrays. The system allows for testing of several performance characteristics of ROIC-fabricated microbolometer arrays including NETD, SiTF, ROIC functionality, noise and matrix operability, both before and after microbolometer fabrication. The system accepts wafers up to 8 inches in diameter and performs automated wafer die mapping using a microscope camera. Once wafer mapping is completed, a custom-designed quick insertion 8-12 μm AR-coated Germanium viewport is placed and the chamber is pumped down to below 10-5 Torr, allowing for the evaluation of package-level focal plane array (FPA) performance. The probe card is electrically connected to an INO IRXCAM camera core, a versatile system that can be adapted to many types of ROICs using custom-built interface printed circuit boards (PCBs). We currently have the capability for testing 384x288, 35 μm pixel size and 160x120, 52 μm pixel size FPAs. For accurate NETD measurements, the system is designed to provide an F/1 view of two rail-mounted blackbodies seen through the Germanium window by the die under test. A master control computer automates the alignment of the probe card to the dies, the positioning of the blackbodies, FPA image frame acquisition using IRXCAM, as well as data analysis and storage. Radiometric measurement precision has been validated by packaging dies measured by the automated probing system and re-measuring the SiTF and Noise using INO's pre-existing benchtop system.

  19. Porous MnO/C of composite nanostructure consisting of nanorods and nano-octahedra as anode of lithium ion batteries with enhanced electrochemical performances

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yue-Feng; Xu, Gui-Liang [State Key Laboratory of Physical Chemistry of Solid Surfaces, Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005 (China); Su, Hang [College of Energy, Xiamen University, Xiamen 361005 (China); Chen, Yuan; Fang, Jun-Chuan; Wang, Qi; Huang, Ling [State Key Laboratory of Physical Chemistry of Solid Surfaces, Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005 (China); Li, Jun-Tao [College of Energy, Xiamen University, Xiamen 361005 (China); Sun, Shi-Gang, E-mail: sgsun@xmu.edu.cn [State Key Laboratory of Physical Chemistry of Solid Surfaces, Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005 (China)

    2016-08-15

    Porous MnO/C materials of composite nanostructure consisting of nanorods and nano-octahedra (denoted as nRO-MnO/C) were synthesized for the first time through a one-pot hydrothermal procedure followed by thermal annealing using PEG6000 as a soft template. When served as anode of LIBs, the nRO-MnO/C materials could maintain a reversible capacity as high as 861.3 mAh g{sup −1} after 120 cycles at a rate of 0.13 C (1 C = 755.6 mA g{sup −1}), and a stable capacity of 313.5 mAh g{sup −1} at a much higher rate of 4.16 C. Moreover, excellent long cycleability at high rate has been also evidenced by a capacity of 628.9 mAh g{sup −1} measured after 300 cycles at 1.32 C. In comparison with mono-form porous nanorods (nR-MnO/C) and mono-form porous nano-octahedra (nO-MnO/C), the enhanced electrochemical performances of the nRO-MnO/C materials are attributed to the composite nanostructure, in which the nano-octahedra contact effectively with nanorods by laying in the space between them yielding synergy effect that facilitates the electronic transportation on electrode. - Highlights: • Porous MnO/C with composite nanostructure was prepared by hydrothermal reaction. • The composite nanostructure is consisting of nanorods and nano-octahedra. • The nRO-MnO/C delivers a charge capacity of 628.9 mAh g{sup −1} after 300 cycles at 1.32 C. • The superior electrochemical performance should be owed to composite structure.

  20. Sexually transmitted infection testing of adult film performers: is disease being missed?

    Science.gov (United States)

    Rodriguez-Hart, Cristina; Chitale, Rohit A; Rigg, Robert; Goldstein, Binh Y; Kerndt, Peter R; Tavrow, Paula

    2012-12-01

    Undiagnosed sexually transmitted infections (STIs) may be common in the adult film industry because performers frequently engage in unprotected oral and anal intercourse, STIs are often asymptomatic, and the industry relies on urine-based testing. Between mid-May and mid-September 2010, a consecutive sample of adult film industry performers recruited from a clinic in Los Angeles, California, that provides medical care to performers was offered oropharyngeal, rectal, and urogenital testing for Gonorrhea, and rectal and urogenital testing for Chlamydia. During the 4-month study period, 168 participants were enrolled: 112 (67%) were female and 56 (33%) were male. Of the 47 (28%) who tested positive for Gonorrhea and/or Chlamydia, 11 (23%) cases would not have been detected through urogenital testing alone. Gonorrhea was the most common STI (42/168; 25%) and the oropharynx the most common site of infection (37/47; 79%). Thirty-five (95%) oropharyngeal and 21 (91%) rectal infections were asymptomatic. Few participants reported using condoms consistently while performing or with their personal sex partners. Adult film industry performers had a high burden of STIs. Undiagnosed asymptomatic rectal and oropharyngeal STIs were common and are likely reservoirs for transmission to sexual partners inside and outside the workplace. Performers should be tested at all anatomical sites irrespective of symptoms, and condom use should be enforced to protect workers in this industry.

  1. Test objects for evaluating the performance of radiological imaging systems. Leeds radiological test objects

    International Nuclear Information System (INIS)

    Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.

    1985-01-01

    A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)

  2. Agility in Team Sports: Testing, Training and Factors Affecting Performance.

    Science.gov (United States)

    Paul, Darren J; Gabbett, Tim J; Nassis, George P

    2016-03-01

    Agility is an important characteristic of team sports athletes. There is a growing interest in the factors that influence agility performance as well as appropriate testing protocols and training strategies to assess and improve this quality. The objective of this systematic review was to (1) evaluate the reliability and validity of agility tests in team sports, (2) detail factors that may influence agility performance, and (3) identify the effects of different interventions on agility performance. The review was undertaken in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We conducted a search of PubMed, Google Scholar, Science Direct, and SPORTDiscus databases. We assessed the methodological quality of intervention studies using a customized checklist of assessment criteria. Intraclass correlation coefficient values were 0.80-0.91, 0.10-0.81, and 0.81-0.99 for test time using light, video, and human stimuli. A low-level reliability was reported for youth athletes using the video stimulus (0.10-0.30). Higher-level participants were shown to be, on average, 7.5% faster than their lower level counterparts. Reaction time and accuracy, foot placement, and in-line lunge movement have been shown to be related to agility performance. The contribution of strength remains unclear. Efficacy of interventions on agility performance ranged from 1% (vibration training) to 7.5% (small-sided games training). Agility tests generally offer good reliability, although this may be compromised in younger participants responding to various scenarios. A human and/or video stimulus seems the most appropriate method to discriminate between standard of playing ability. Decision-making and perceptual factors are often propositioned as discriminant factors; however, the underlying mechanisms are relatively unknown. Research has focused predominantly on the physical element of agility. Small-sided games and video training may offer effective

  3. 1997 Performance Testing of Multi-Metal Continuous Emissions Monitors

    International Nuclear Information System (INIS)

    1998-01-01

    Five prototype and two commercially available multi-metals continuous emissions monitors (CEMs) were tested in September 1997 at the Rotary Kiln Incinerator Simulator facility at the EPA National Risk Management Research Laboratory, Research Triangle Park, North Carolina. The seven CEMs were tested side by side in a long section of duct following the secondary combustion chamber of the RKIS. Two different concentrations of six toxic metals were introduced into the incinerator-approximately 15 and 75 g/dscm of arsenic, beryllium, cadmium, chromium, lead, and mercury (We also tested for antimony but we are not reporting on it here because EPA recently dropped antimony from the list of metals addressed by the draft MACT rule). These concentrations were chosen to be close to emission standards in the draft MACT rule and the estimated Method Detection Limit (MDL) required of a CEM for regulatory compliance purposes. Results from this test show that no CEMs currently meet the performance specifications in the EPA draft MACT rule for hazardous waste incinerators. Only one of the CEMs tested was able to measure all six metals at the concentrations tested. Even so, the relative accuracy of this CEM varied between 35% and 100%, not 20% or less as required in the EPA performance specification. As a result, we conclude that no CEM is ready for long-term performance validation for compliance monitoring applications. Because sampling and measuring Hg is a recurring problem for multi-metal CEMs as well as Hg CEMs, we recommended that developers participate in a 1998 DOE-sponsored workshop to solve these and other common CEM measurement issues

  4. Comparison of driving simulator performance and neuropsychological testing in narcolepsy.

    Science.gov (United States)

    Kotterba, Sylvia; Mueller, Nicole; Leidag, Markus; Widdig, Walter; Rasche, Kurt; Malin, Jean-Pierre; Schultze-Werninghaus, Gerhard; Orth, Maritta

    2004-09-01

    Daytime sleepiness and cataplexy can increase automobile accident rates in narcolepsy. Several countries have produced guidelines for issuing a driving license. The aim of the study was to compare driving simulator performance and neuropsychological test results in narcolepsy in order to evaluate their predictive value regarding driving ability. Thirteen patients with narcolepsy (age: 41.5+/-12.9 years) and 10 healthy control patients (age: 55.1+/-7.8 years) were investigated. By computer-assisted neuropsychological testing, vigilance, alertness and divided attention were assessed. In a driving simulator patients and controls had to drive on a highway for 60 min (mean speed of 100 km/h). Different weather and daytime conditions and obstacles were presented. Epworth Sleepiness Scale-Scores were significantly raised (narcolepsy patients: 16.7+/-5.1, controls: 6.6+/-3.6, P divided attention (56.9+/-25.4) and vigilance (58.7+/-26.8) were in a normal range. There was, however, a high inter-individual difference. There was no correlation between driving performance and neuropsychological test results or ESS Score. Neuropsychological test results did not significantly change in the follow-up. The difficulties encountered by the narcolepsy patient in remaining alert may account for sleep-related motor vehicle accidents. Driving simulator investigations are closely related to real traffic situations than isolated neuropsychological tests. At the present time the driving simulator seems to be a useful instrument judging driving ability especially in cases with ambiguous neuropsychological results.

  5. Beam test performance of the APV5 chip

    International Nuclear Information System (INIS)

    De Fez-Laso, M.D.M.; Gill, K.; MacEvoy, B.; Millmore, M.; Potts, A.; Raymond, M.

    1996-01-01

    The performance of the latest prototype of the radiation hard front end chip to be used by the CMS collaboration for analogue readout of the microstrip tracker has been evaluated with a silicon microstrip detector in a beam at CERN. The circuit, developed by the RD20 collaboration, consists of 128 channels of amplifier, pipeline memory, analogue signal processor and a serial multiplexer. As a result of these studies improvements in the circuit design have been devised which will be implemented in the next version. (orig.)

  6. Rheological Method for Alpha Test Evaluation of Developing Superplasticizers’ Performance: Channel Flow Test

    Directory of Open Access Journals (Sweden)

    Jae Hong Kim

    2017-01-01

    Full Text Available Advance in high-range water-reducing admixture revolutionizes the workability and constructability of conventional vibrated concrete as well as self-consolidating concrete. Its need from construction fields has increased, and consequently a variety of new-type polycarboxylates, base polymers for the admixture, are being formulated in these days. Synthesizing new polymers needs a quick, but reliable, test to evaluate its performance on concrete. The test is also asked for selecting the best applicable brand of them before a test concrete will be mixed. This paper proposes a “channel flow test” and its usage for the purpose. The proposed procedure for the test includes the mix proportion of a test mortar, the test method, and rheological interpretation of the test results.

  7. A LABORATORY TEST FOR THE EXAMINATION OF ALACTIC RUNNING PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Armin Kibele

    2005-12-01

    Full Text Available A new testing procedure is introduced to evaluate the alactic running performance in a 10s sprint task with near-maximal movement velocity. The test is performed on a motor-equipped treadmill with inverted polarity that increases mechanical resistance instead of driving the treadmill belt. As a result, a horizontal force has to be exerted against the treadmill surface in order to overcome the resistant force of the engine and to move the surface in a backward direction. For this task, subjects lean with their hands towards the front safety barrier of the treadmill railing with a slightly inclined body posture. The required skill resembles the pushing movement of bobsleigh pilots at the start of a race. Subjects are asked to overcome this mechanical resistance and to cover as much distance as possible within a time period of 10 seconds. Fifteen male students (age: 27.7 ± 4.1 years, body height: 1.82 ± 0.46 m, body mass: 78.3 ± 6.7 kg participated in a study. As the resistance force was set to 134 N, subjects ran 35.4 ± 2.6 m on the average corresponding to a mean running velocity of 3.52 ± 0.25 m·s-1. The validity of the new test was examined by statistical inference with various measures related to alactic performance including a metabolic equivalent to estimate alactic capacity (2892 ± 525 mL O2, an estimate for the oxygen debt (2662 ± 315 ml, the step test by Margaria to estimate alactic energy flow (1691 ± 171 W, and a test to measure the maximal strength in the leg extensor muscles (2304 ± 351 N. The statistical evaluation showed that the new test is in good agreement with the theoretical assumptions for alactic performance. Significant correlation coefficients were found between the test criteria and the measures for alactic capacity (r = 0.79, p < 0.01 as well as alactic power (r = 0.77, p < 0.01. The testing procedure is easy to administer and it is best suited to evaluate the alactic capacity for bobsleigh pilots as well as for

  8. Performance of CREAM Calorimeter Results of Beam Tests

    CERN Document Server

    Ahn, H S; Beatty, J J; Bigongiari, G; Castellina, A; Childers, J T; Conklin, N B; Coutu, S; Duvernois, M A; Ganel, O; Han, J H; Hyun, H J; Kang, T G; Kim, H J; Kim, K C; Kim, M Y; Kim, T; Kim, Y J; Lee, J K; Lee, M H; Lutz, L; Maestro, P; Malinine, A; Marrocchesi, P S; Mognet, S I; Nam, S W; Nutter, S; Park, N H; Park, H; Seo, E S; Sina, R; Syed, S; Song, C; Swordy, S; Wu, J; Yang, J; Zhang, H Q; Zei, R; Zinn, S Y

    2005-01-01

    The Cosmic Ray Energetics And Mass (CREAM), a balloon-borne experiment, is under preparation for a flight in Antarctica at the end of 2004. CREAM is planned to measure the energy spectrum and composition of cosmic rays directly at energies between 1 TeV and 1000 TeV. Incident particle energies will be measured by a transition radiation detector and a sampling calorimeter. The calorimeter was constructed at the University of Maryland and tested at CERN in 2003. Performance of the calorimeter during the beam tests is reported.

  9. Thermal performance test for steam turbine of nuclear power plants

    International Nuclear Information System (INIS)

    Bu Yubing; Xu Zongfu; Wang Shiyong

    2014-01-01

    Through study of steam turbine thermal performance test of CPR1000 nuclear power plant, we solve the enthalpy calculation problems of the steam turbine in wet steam zone using heat balance method which can help to figure out the real overall heat balance diagram for the first time, and we develop a useful software for thermal heat balance calculation. Ling'ao phase II as an example, this paper includes test instrument layout, system isolation, risk control, data acquisition, wetness measurement, heat balance calculation, etc. (authors)

  10. Reliability performance of standby equipment with periodic testing

    International Nuclear Information System (INIS)

    Sim, S.H.

    1985-11-01

    In this report, the reliability performance of standby equipment subjected to periodic testing is studied. analytical expressions have been derived for reliability measures, such as the man accumulated operating time to failure, the expected number of tests between two consecutive failures, the mean time to failure following an emergency start-up and the probability of failing to complete an emergency mission of a specified duration. These results are useful for the reliability assessment of standby equipment such as combustion turbine units of the emergency power supply system, and of the Class III power system at a nuclear generating station

  11. Performance tests for instruments measuring radon activity concentration

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Schmidt, V.

    2009-01-01

    Performance tests of electronic instruments measuring the activity concentration of 222 Rn have been carried out with respect to the standard IEC 61577-2. In total, 9 types of instrument operating with ionization chambers or electrostatic collection have been tested for the influence of different climatic and radiological factors on the measurement characteristics. It is concluded that all types of instrument, which are commercially available, are suitable for indoor radon measurements. Because of the dependence on climatic conditions, the outdoor use is partly limited.

  12. Results of tritium tests performed on Sandia Laboratories decontamination system

    International Nuclear Information System (INIS)

    Gildea, P.D.; Wall, W.R.; Gede, V.P.

    1978-05-01

    The Tritium Research Laboratory (TRL), a facility for performing experiments using gram amounts of tritium, became operational on October 1, 1977. As secondary containment, the TRL employs sealed glove boxes connected on demand to two central decontamination systems, the Gas Purification System and the Vacuum Effluent Recovery System. Performance tests on these systems show the tritium removal systems can achieve concentration reduction factors (ratio of inlet to exhaust concentrations) much in excess of 1000 per pass at inlet concentrations of 1 part per million or less for both tritium and tritiated methane

  13. Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

    Energy Technology Data Exchange (ETDEWEB)

    Fuehne, David Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lattin, Rebecca Renee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-28

    The Rad-NESHAP program, part of the Air Quality Compliance team of LANL’s Compliance Programs group (EPC-CP), and the Radiation Instrumentation & Calibration team, part of the Radiation Protection Services group (RP-SVS), frequently partner on issues relating to characterizing air flow streams. This memo documents the most recent example of this partnership, involving performance testing of sulfur hexafluoride detectors for use in stack gas mixing tests. Additionally, members of the Rad-NESHAP program performed a functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument. Prior to commissioning a new stack sampling system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniformity of tracer gas and aerosol mixing in the air stream. For these mix tests, tracer media (sulfur hexafluoride gas or liquid oil aerosol particles) are injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of these media concentrations must be under 20% when evaluated over the central 2/3 area of the stack or duct. The instruments which measure these air concentrations must be tested prior to the stack tests in order to ensure their linear response to varying air concentrations of either tracer gas or tracer aerosol. The instruments used in tracer gas and aerosol mix testing cannot be calibrated by the LANL Standards and Calibration Laboratory, so they would normally be sent off-site for factory calibration by the vendor. Operational requirements can prevent formal factory calibration of some instruments after they have been used in hazardous settings, e.g., within a radiological facility with potential airborne contamination. The performance tests described in this document are intended to demonstrate the reliable

  14. Recommended procedures for performance testing of radiobioassay laboratories: Volume 1, Quality assurance

    International Nuclear Information System (INIS)

    Fenrick, H.W.; MacLellan, J.A.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed in response to a concern expressed by the US Department of Energy and US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard specifies the criteria for defining the procedures necessary to establish a bioassay performance-testing laboratory and program. The testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped define responsibilities and develop procedures as part of an effort to evaluate the draft ANSI N13.30 performance criteria for quality assurance at bioassay laboratories. This report recommends elements of quality assurance and quality control responsibilities for the bioassay performance-testing laboratory program, including the qualification and performance of personnel and the calibration, certification, and performance of equipment. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented. 15 refs

  15. Reliability, validity and description of timed performance of the Jebsen-Taylor Test in patients with muscular dystrophies.

    Science.gov (United States)

    Artilheiro, Mariana Cunha; Fávero, Francis Meire; Caromano, Fátima Aparecida; Oliveira, Acary de Souza Bulle; Carvas, Nelson; Voos, Mariana Callil; Sá, Cristina Dos Santos Cardoso de

    2017-12-08

    The Jebsen-Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen-Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen-Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test-retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen-Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen-Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903-0.999), except for writing with an Intraclass correlation coefficient of 0.772-1.000. Strong correlations between the Jebsen-Taylor Test and the Performance of Upper Limb Module were found (rho=-0.712). The Jebsen-Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  16. Performance testing of 3D point cloud software

    Science.gov (United States)

    Varela-González, M.; González-Jorge, H.; Riveiro, B.; Arias, P.

    2013-10-01

    LiDAR systems are being used widely in recent years for many applications in the engineering field: civil engineering, cultural heritage, mining, industry and environmental engineering. One of the most important limitations of this technology is the large computational requirements involved in data processing, especially for large mobile LiDAR datasets. Several software solutions for data managing are available in the market, including open source suites, however, users often unknown methodologies to verify their performance properly. In this work a methodology for LiDAR software performance testing is presented and four different suites are studied: QT Modeler, VR Mesh, AutoCAD 3D Civil and the Point Cloud Library running in software developed at the University of Vigo (SITEGI). The software based on the Point Cloud Library shows better results in the loading time of the point clouds and CPU usage. However, it is not as strong as commercial suites in working set and commit size tests.

  17. Performance test of the CMS link alignment system

    CERN Document Server

    Arce, P; Calvo, E; Fernández, M G; Ferrando, A; Figueroa, C F; García, N; Josa-Mutuberria, I; Molinero, A; Oller, J C; Rodrigo, T; Vila, I; Virto, A L

    2002-01-01

    A first global test of the CMS Alignment System was performed at the I4 hall of the CERN ISR tunnel. Positions of the network, reproducing a set of points in the CMS detector monitored by the Link System, were reconstructed and compared to survey measurements. Spatial and angular reconstruction precisions reached in the present experimental set-up are already close to the CMS requirements.

  18. Development of Testing Methodologies to Evaluate Postflight Locomotor Performance

    Science.gov (United States)

    Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Richards, J. T.; Miller, C. A.; Brady, R.; Warren, L. E.; Bloomberg, J. J.

    2006-01-01

    Crewmembers experience locomotor and postural instabilities during ambulation on Earth following their return from space flight. Gait training programs designed to facilitate recovery of locomotor function following a transition to a gravitational environment need to be accompanied by relevant assessment methodologies to evaluate their efficacy. The goal of this paper is to demonstrate the operational validity of two tests of locomotor function that were used to evaluate performance after long duration space flight missions on the International Space Station (ISS).

  19. Testing the performance of a blind burst statistic

    Energy Technology Data Exchange (ETDEWEB)

    Vicere, A [Istituto di Fisica, Universita di Urbino (Italy); Calamai, G [Istituto Nazionale di Fisica Nucleare, Sez. Firenze/Urbino (Italy); Campagna, E [Istituto Nazionale di Fisica Nucleare, Sez. Firenze/Urbino (Italy); Conforto, G [Istituto di Fisica, Universita di Urbino (Italy); Cuoco, E [Istituto Nazionale di Fisica Nucleare, Sez. Firenze/Urbino (Italy); Dominici, P [Istituto di Fisica, Universita di Urbino (Italy); Fiori, I [Istituto di Fisica, Universita di Urbino (Italy); Guidi, G M [Istituto di Fisica, Universita di Urbino (Italy); Losurdo, G [Istituto Nazionale di Fisica Nucleare, Sez. Firenze/Urbino (Italy); Martelli, F [Istituto di Fisica, Universita di Urbino (Italy); Mazzoni, M [Istituto Nazionale di Fisica Nucleare, Sez. Firenze/Urbino (Italy); Perniola, B [Istituto di Fisica, Universita di Urbino (Italy); Stanga, R [Istituto Nazionale di Fisica Nucleare, Sez. Firenze/Urbino (Italy); Vetrano, F [Istituto di Fisica, Universita di Urbino (Italy)

    2003-09-07

    In this work, we estimate the performance of a method for the detection of burst events in the data produced by interferometric gravitational wave detectors. We compute the receiver operating characteristics in the specific case of a simulated noise having the spectral density expected for Virgo, using test signals taken from a library of possible waveforms emitted during the collapse of the core of type II supernovae.

  20. Are There Consistent Grazing Indicators in Drylands? Testing Plant Functional Types of Various Complexity in South Africa’s Grassland and Savanna Biomes

    Science.gov (United States)

    Linstädter, Anja; Schellberg, Jürgen; Brüser, Katharina; Moreno García, Cristian A.; Oomen, Roelof J.; du Preez, Chris C.; Ruppert, Jan C.; Ewert, Frank

    2014-01-01

    Despite our growing knowledge on plants’ functional responses to grazing, there is no consensus if an optimum level of functional aggregation exists for detecting grazing effects in drylands. With a comparative approach we searched for plant functional types (PFTs) with a consistent response to grazing across two areas differing in climatic aridity, situated in South Africa’s grassland and savanna biomes. We aggregated herbaceous species into PFTs, using hierarchical combinations of traits (from single- to three-trait PFTs). Traits relate to life history, growth form and leaf width. We first confirmed that soil and grazing gradients were largely independent from each other, and then searched in each biome for PFTs with a sensitive response to grazing, avoiding confounding with soil conditions. We found no response consistency, but biome-specific optimum aggregation levels. Three-trait PFTs (e.g. broad-leaved perennial grasses) and two-trait PFTs (e.g. perennial grasses) performed best as indicators of grazing effects in the semi-arid grassland and in the arid savanna biome, respectively. Some PFTs increased with grazing pressure in the grassland, but decreased in the savanna. We applied biome-specific grazing indicators to evaluate if differences in grazing management related to land tenure (communal versus freehold) had effects on vegetation. Tenure effects were small, which we mainly attributed to large variability in grazing pressure across farms. We conclude that the striking lack of generalizable PFT responses to grazing is due to a convergence of aridity and grazing effects, and unlikely to be overcome by more refined classification approaches. Hence, PFTs with an opposite response to grazing in the two biomes rather have a unimodal response along a gradient of additive forces of aridity and grazing. The study advocates for hierarchical trait combinations to identify localized indicator sets for grazing effects. Its methodological approach may also be

  1. Are there consistent grazing indicators in Drylands? Testing plant functional types of various complexity in South Africa's Grassland and Savanna Biomes.

    Directory of Open Access Journals (Sweden)

    Anja Linstädter

    Full Text Available Despite our growing knowledge on plants' functional responses to grazing, there is no consensus if an optimum level of functional aggregation exists for detecting grazing effects in drylands. With a comparative approach we searched for plant functional types (PFTs with a consistent response to grazing across two areas differing in climatic aridity, situated in South Africa's grassland and savanna biomes. We aggregated herbaceous species into PFTs, using hierarchical combinations of traits (from single- to three-trait PFTs. Traits relate to life history, growth form and leaf width. We first confirmed that soil and grazing gradients were largely independent from each other, and then searched in each biome for PFTs with a sensitive response to grazing, avoiding confounding with soil conditions. We found no response consistency, but biome-specific optimum aggregation levels. Three-trait PFTs (e.g. broad-leaved perennial grasses and two-trait PFTs (e.g. perennial grasses performed best as indicators of grazing effects in the semi-arid grassland and in the arid savanna biome, respectively. Some PFTs increased with grazing pressure in the grassland, but decreased in the savanna. We applied biome-specific grazing indicators to evaluate if differences in grazing management related to land tenure (communal versus freehold had effects on vegetation. Tenure effects were small, which we mainly attributed to large variability in grazing pressure across farms. We conclude that the striking lack of generalizable PFT responses to grazing is due to a convergence of aridity and grazing effects, and unlikely to be overcome by more refined classification approaches. Hence, PFTs with an opposite response to grazing in the two biomes rather have a unimodal response along a gradient of additive forces of aridity and grazing. The study advocates for hierarchical trait combinations to identify localized indicator sets for grazing effects. Its methodological approach may

  2. Are there consistent grazing indicators in Drylands? Testing plant functional types of various complexity in South Africa's Grassland and Savanna Biomes.

    Science.gov (United States)

    Linstädter, Anja; Schellberg, Jürgen; Brüser, Katharina; Moreno García, Cristian A; Oomen, Roelof J; du Preez, Chris C; Ruppert, Jan C; Ewert, Frank

    2014-01-01

    Despite our growing knowledge on plants' functional responses to grazing, there is no consensus if an optimum level of functional aggregation exists for detecting grazing effects in drylands. With a comparative approach we searched for plant functional types (PFTs) with a consistent response to grazing across two areas differing in climatic aridity, situated in South Africa's grassland and savanna biomes. We aggregated herbaceous species into PFTs, using hierarchical combinations of traits (from single- to three-trait PFTs). Traits relate to life history, growth form and leaf width. We first confirmed that soil and grazing gradients were largely independent from each other, and then searched in each biome for PFTs with a sensitive response to grazing, avoiding confounding with soil conditions. We found no response consistency, but biome-specific optimum aggregation levels. Three-trait PFTs (e.g. broad-leaved perennial grasses) and two-trait PFTs (e.g. perennial grasses) performed best as indicators of grazing effects in the semi-arid grassland and in the arid savanna biome, respectively. Some PFTs increased with grazing pressure in the grassland, but decreased in the savanna. We applied biome-specific grazing indicators to evaluate if differences in grazing management related to land tenure (communal versus freehold) had effects on vegetation. Tenure effects were small, which we mainly attributed to large variability in grazing pressure across farms. We conclude that the striking lack of generalizable PFT responses to grazing is due to a convergence of aridity and grazing effects, and unlikely to be overcome by more refined classification approaches. Hence, PFTs with an opposite response to grazing in the two biomes rather have a unimodal response along a gradient of additive forces of aridity and grazing. The study advocates for hierarchical trait combinations to identify localized indicator sets for grazing effects. Its methodological approach may also be useful

  3. Performance of a 2-megawatt high voltage test load

    International Nuclear Information System (INIS)

    Horan, D.; Kustom, R.; Ferguson, M.

    1995-01-01

    A high-power, water-cooled resistive load which simulates the electrical load characteristics of a high-power klystron, capable of 2 megawatts dissipation at 95 kV DC, was built and installed at the Advanced Photon Source for use in load-testing high voltage power supplies. During this testing, the test load has logged approximately 35 hours of operation at power levels in excess of one mezawatt. Slight variations in the resistance of the load during operation indicate that leakage currents in the cooling water may be a significant factor affecting the performance of the load. Sufficient performance data have been collected to indicate that leakage current through the deionized (DI) water coolant shunts roughly 15 percent of the full-load current around the load resistor elements. The leakage current could cause deterioration of internal components of the load. The load pressure vessel was disassembled and inspected internally for any signs of significant wear and distress. Results of this inspection and possible modifications for improved performance will be discussed

  4. Achievement test performance in children conceived by IVF.

    Science.gov (United States)

    Mains, L; Zimmerman, M; Blaine, J; Stegmann, B; Sparks, A; Ansley, T; Van Voorhis, B

    2010-10-01

    Long-term follow-up studies of children conceived by IVF are limited. We examine academic performance on standardized tests [Iowa Tests of Basic Skills/Educational Development (ITBS/ITED)] of children conceived by IVF. Parents of children 8-17 years of age at the onset of the study (March 2008) who were conceived by IVF at the University of Iowa Hospitals and Clinics and living in the state of Iowa were contacted by mail. Parents completed questionnaires on their child's health and education and parental education. ITBS/ITED scores from school grades 3-12 were obtained on IVF children and a group of anonymous children matched by grade, year, gender and school district. Scores were analyzed using linear mixed models. Four hundred and ninety-seven couples were contacted. Two hundred and ninety-five couples (463 children) agreed to participate (59.4% of parents), with ITBS/ITED scores available on 423 children (91.4% of participants). IVF children scored higher than the national mean (P divorce and child's BMI. Cryopreservation, length of embryo culture and method of insemination did not affect scores. IVF children scored higher on standardized tests than their matched peers, suggesting that IVF does not have a negative effect on cognitive development. However, long-term follow-up of IVF children is still limited. Further research should be performed on the effect of multiple gestation on academic performance.

  5. Test Program for the Performance Analysis of DNS64 Servers

    Directory of Open Access Journals (Sweden)

    Gábor Lencse

    2015-09-01

    Full Text Available In our earlier research papers, bash shell scripts using the host Linux command were applied for testing the performance and stability of different DNS64 server imple­mentations. Because of their inefficiency, a small multi-threaded C/C++ program (named dns64perf was written which can directly send DNS AAAA record queries. After the introduction to the essential theoretical background about the structure of DNS messages and TCP/IP socket interface programming, the design decisions and implementation details of our DNS64 performance test program are disclosed. The efficiency of dns64perf is compared to that of the old method using bash shell scripts. The result is convincing: dns64perf can send at least 95 times more DNS AAAA record queries per second. The source code of dns64perf is published under the GNU GPLv3 license to support the work of other researchers in the field of testing the performance of DNS64 servers.

  6. Fuel leak testing performance at NPP Jaslovske Bohunice

    International Nuclear Information System (INIS)

    Slugen, V.; Krnac, S.; Smiesko, I.

    1995-01-01

    The NPP Bohunice VVER-440 fuel leak testing experience are relatively extensive in comparison with other VVER-440 users. As the first Europe NPP was adapted Siemens (KWU) in core-sipping equipment to VVER-440 units and since this time were have done these tests also for NPP Paks (Hungary) and NPP Dukovany (Czech Republic). The occurrence of leaking fuel assemblies in NPP is in the last 5 years relatively stabilised and low. A significant difference can be observed between type V-230 (31 leaks) and type V-213 (1 leak). None of of the indicated leaking fuel assemblies has been investigated in the hot cell. Therefore cannot be confirm the effective causes of leak occurrence. Nevertheless, the fuel failure rate and the performance of leak testing in NPP Bohunice are comparable to the world standard at PWR's. 1 tab., 2 figs., 3 refs

  7. Fuel leak testing performance at NPP Jaslovske Bohunice

    Energy Technology Data Exchange (ETDEWEB)

    Slugen, V; Krnac, S [Slovak Technical Univ., Bratislava (Slovakia); Smiesko, I [Nuclear Powr Plant EBO, Jaslovske Bohuce (Slovakia)

    1996-12-31

    The NPP Bohunice VVER-440 fuel leak testing experience are relatively extensive in comparison with other VVER-440 users. As the first Europe NPP was adapted Siemens (KWU) in core-sipping equipment to VVER-440 units and since this time were have done these tests also for NPP Paks (Hungary) and NPP Dukovany (Czech Republic). The occurrence of leaking fuel assemblies in NPP is in the last 5 years relatively stabilised and low. A significant difference can be observed between type V-230 (31 leaks) and type V-213 (1 leak). None of of the indicated leaking fuel assemblies has been investigated in the hot cell. Therefore cannot be confirm the effective causes of leak occurrence. Nevertheless, the fuel failure rate and the performance of leak testing in NPP Bohunice are comparable to the world standard at PWR`s. 1 tab., 2 figs., 3 refs.

  8. Performance test of ex-core high temperature and high pressure water loop test equipment (Contract research)

    International Nuclear Information System (INIS)

    Nakano, Hiroko; Uehara, Toshiaki; Takeuchi, Tomoaki; Shibata, Hiroshi; Nakamura, Jinichi; Matsui, Yoshinori; Tsuchiya, Kunihiko

    2016-03-01

    In Japan Atomic Energy Agency, we started research and development so as to monitor the situations in the Nuclear Plant Facilities during a severe accident, such as a radiation-resistant monitoring camera, a radiation-resistant transmission system for conveying the in-core information, and a heat-resistant signal cable. As a part of developments of the heat-resistant signal cable, we prepared ex-core high-temperature and high-pressure water loop test equipment, which can simulate the conditions of BWRs and PWRs, for evaluating reliability and properties of sheath materials of the cable. This equipment consists of autoclave, water conditioning tank, high-pressure metering pump, preheater, heat exchanger and water purification equipment, etc. This report describes the basic design and the performance test results of ex-core high-temperature and high-pressure water loop test equipment. (author)

  9. Can the Immune System Perform a t-Test?

    Science.gov (United States)

    Faria, Bruno Filipe; Mostardinha, Patricia

    2017-01-01

    The self-nonself discrimination hypothesis remains a landmark concept in immunology. It proposes that tolerance breaks down in the presence of nonself antigens. In strike contrast, in statistics, occurrence of nonself elements in a sample (i.e., outliers) is not obligatory to violate the null hypothesis. Very often, what is crucial is the combination of (self) elements in a sample. The two views on how to detect a change seem challengingly different and it could seem difficult to conceive how immunological cellular interactions could trigger responses with a precision comparable to some statistical tests. Here it is shown that frustrated cellular interactions reconcile the two views within a plausible immunological setting. It is proposed that the adaptive immune system can be promptly activated either when nonself ligands are detected or self-ligands occur in abnormal combinations. In particular we show that cellular populations behaving in this way could perform location statistical tests, with performances comparable to t or KS tests, or even more general data mining tests such as support vector machines or random forests. In more general terms, this work claims that plausible immunological models should provide accurate detection mechanisms for host protection and, furthermore, that investigation on mechanisms leading to improved detection in “in silico” models can help unveil how the real immune system works. PMID:28046042

  10. The Principle of Energetic Consistency

    Science.gov (United States)

    Cohn, Stephen E.

    2009-01-01

    A basic result in estimation theory is that the minimum variance estimate of the dynamical state, given the observations, is the conditional mean estimate. This result holds independently of the specifics of any dynamical or observation nonlinearity or stochasticity, requiring only that the probability density function of the state, conditioned on the observations, has two moments. For nonlinear dynamics that conserve a total energy, this general result implies the principle of energetic consistency: if the dynamical variables are taken to be the natural energy variables, then the sum of the total energy of the conditional mean and the trace of the conditional covariance matrix (the total variance) is constant between observations. Ensemble Kalman filtering methods are designed to approximate the evolution of the conditional mean and covariance matrix. For them the principle of energetic consistency holds independently of ensemble size, even with covariance localization. However, full Kalman filter experiments with advection dynamics have shown that a small amount of numerical dissipation can cause a large, state-dependent loss of total variance, to the detriment of filter performance. The principle of energetic consistency offers a simple way to test whether this spurious loss of variance limits ensemble filter performance in full-blown applications. The classical second-moment closure (third-moment discard) equations also satisfy the principle of energetic consistency, independently of the rank of the conditional covariance matrix. Low-rank approximation of these equations offers an energetically consistent, computationally viable alternative to ensemble filtering. Current formulations of long-window, weak-constraint, four-dimensional variational methods are designed to approximate the conditional mode rather than the conditional mean. Thus they neglect the nonlinear bias term in the second-moment closure equation for the conditional mean. The principle of

  11. Usefulness of the jump-and-reach test in assessment of vertical jump performance.

    Science.gov (United States)

    Menzel, Hans-Joachim; Chagas, Mauro H; Szmuchrowski, Leszek A; Araujo, Silvia R; Campos, Carlos E; Giannetti, Marcus R

    2010-02-01

    The objective was to estimate the reliability and criterion-related validity of the Jump-and-Reach Test for the assessment of squat, countermovement, and drop jump performance of 32 male Brazilian professional volleyball players. Performance of squat, countermovement, and drop jumps with different dropping heights was assessed on the Jump-and-Reach Test and the measurement of flight time, then compared across different jump trials. The very high reliability coefficients of both assessment methods and the lower correlation coefficients between scores on the assessments indicate a very high consistency of each method but only moderate covariation, which means that they measure partly different items. As a consequence, the Jump-and-Reach Test has good ecological validity in situations when reaching height during the flight phase is critical for performance (e.g., basketball and volleyball) but only limited accuracy for the assessment of vertical impulse production with different jump techniques and conditions.

  12. Performance measurements at the fast flux test facility

    International Nuclear Information System (INIS)

    Baumhardt, R.J.; Newland, D.J.; Praetorius, P.R.

    1987-01-01

    In 1984, Fast Flux Test Facility (FFTF) management recognized the need to develop a measurement system that would quantify the operational performance of the FFTF and the human resources needed to operate it. Driven by declining budgets and the need to safely manage a manpower rampdown at FFTF, an early warning system was developed. Although the initiating event for the early warning system was the need to safely manage a manpower rampdown, many related uses have evolved. The initial desired objective for the FFTF performance measurements was to ensure safety and control of key performance trends. However, the early warning system has provided a more quantitative, supportable basis upon which to make decisions. From this initial narrow focus, efforts in the FFTF plant and supporting organizations are leading to measurement of and, subsequently, improvements in productivity. Pilot projects utilizing statistical process control have started with longer range productivity improvement

  13. Performance testing of real-time AI systems using the activation framework

    International Nuclear Information System (INIS)

    Becker, L.; Duckworth, J.; Laznovsky, A.; Green, P.

    1992-01-01

    This paper describes methods for automated performance testing of real-time artificial intelligence systems using the Activation Framework software development tool. The Activation Framework is suitable for applications such as the diagnosis of power system failures, which require the interpretation of large volumes of data in real-time. The Activation Framework consists of tools for compiling groups of Expert Systems rules into executable code modules, for automatically generating code modules from high level system configuration descriptions, and for automatically generating command files for program compilation and linking. It includes an operating system environment which provides the code which is common from one real-time AI applications to the next. It also includes mechanisms, described here, for automatic performance testing. The principal emphasis of this paper is on a rule based language which is used to capture performance specifications. This specification is compiled into code modules which are used to automatically test the system. This testing can validate that the system meets performance requirements during development and after maintenance. A large number of tests can be randomly generated and executed and the correctness of the outputs automatically validated. The paper also describes graph directed testing methods to minimize the number of test runs required

  14. Proposed waste form performance criteria and testing methods for low-level mixed waste

    International Nuclear Information System (INIS)

    Franz, E.M.; Fuhrmann, M.; Bowerman, B.

    1995-01-01

    Proposed waste form performance criteria and testing methods were developed as guidance in judging the suitability of solidified waste as a physico-chemical barrier to releases of radionuclides and RCRA regulated hazardous components. The criteria follow from the assumption that release of contaminants by leaching is the single most important property for judging the effectiveness of a waste form. A two-tier regimen is proposed. The first tier consists of a leach test designed to determine the net, forward leach rate of the solidified waste and a leach test required by the Environmental Protection Agency (EPA). The second tier of tests is to determine if a set of stresses (i.e., radiation, freeze-thaw, wet-dry cycling) on the waste form adversely impacts its ability to retain contaminants and remain physically intact. In the absence of site-specific performance assessments (PA), two generic modeling exercises are described which were used to calculate proposed acceptable leachates

  15. Structural Consistency, Consistency, and Sequential Rationality.

    OpenAIRE

    Kreps, David M; Ramey, Garey

    1987-01-01

    Sequential equilibria comprise consistent beliefs and a sequentially ra tional strategy profile. Consistent beliefs are limits of Bayes ratio nal beliefs for sequences of strategies that approach the equilibrium strategy. Beliefs are structurally consistent if they are rationaliz ed by some single conjecture concerning opponents' strategies. Consis tent beliefs are not necessarily structurally consistent, notwithstan ding a claim by Kreps and Robert Wilson (1982). Moreover, the spirit of stru...

  16. Test of a non-physical barrier consisting of light, sound, and bubble screen to block upstream movement of sea lamprey in an experimental raceway

    Science.gov (United States)

    Miehls, Scott M.; Johnson, Nicholas S.; Hrodey, Pete J.

    2017-01-01

    Control of the invasive Sea Lamprey Petromyzon marinus is critical for management of commercial and recreational fisheries in the Laurentian Great Lakes. Use of physical barriers to block Sea Lampreys from spawning habitat is a major component of the control program. However, the resulting interruption of natural streamflow and blockage of nontarget species present substantial challenges. Development of an effective nonphysical barrier would aid the control of Sea Lampreys by eliminating their access to spawning locations while maintaining natural streamflow. We tested the effect of a nonphysical barrier consisting of strobe lights, low-frequency sound, and a bubble screen on the movement of Sea Lampreys in an experimental raceway designed as a two-choice maze with a single main channel fed by two identical inflow channels (one control and one blocked). Sea Lampreys were more likely to move upstream during trials when the strobe light and low-frequency sound were active compared with control trials and trials using the bubble screen alone. For those Sea Lampreys that did move upstream to the confluence of inflow channels, no combination of stimuli or any individual stimulus significantly influenced the likelihood that Sea Lampreys would enter the blocked inflow channel, enter the control channel, or return downstream.

  17. Chemical composition analysis and product consistency tests to support enhanced Hanford waste glass models. Results for the third set of high alumina outer layer matrix glasses

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K. M. [Savannah River Site (SRS), Aiken, SC (United States); Edwards, T. B. [Savannah River Site (SRS), Aiken, SC (United States)

    2015-12-01

    In this report, the Savannah River National Laboratory provides chemical analyses and Product Consistency Test (PCT) results for 14 simulated high level waste glasses fabricated by the Pacific Northwest National Laboratory. The results of these analyses will be used as part of efforts to revise or extend the validation regions of the current Hanford Waste Treatment and Immobilization Plant glass property models to cover a broader span of waste compositions. The measured chemical composition data are reported and compared with the targeted values for each component for each glass. All of the measured sums of oxides for the study glasses fell within the interval of 96.9 to 100.8 wt %, indicating recovery of all components. Comparisons of the targeted and measured chemical compositions showed that the measured values for the glasses met the targeted concentrations within 10% for those components present at more than 5 wt %. The PCT results were normalized to both the targeted and measured compositions of the study glasses. Several of the glasses exhibited increases in normalized concentrations (NCi) after the canister centerline cooled (CCC) heat treatment. Five of the glasses, after the CCC heat treatment, had NCB values that exceeded that of the Environmental Assessment (EA) benchmark glass. These results can be combined with additional characterization, including X-ray diffraction, to determine the cause of the higher release rates.

  18. Pilot test of ANSI draft standard N13.29 environmental dosimetry -- Performance criteria for testing

    International Nuclear Information System (INIS)

    Klemic, G.; Shebell, P.; Monetti, M.; Raccah, F.; Sengupta, S.

    1998-09-01

    American National Standards Institute Draft N13.29 describes performance tests for environmental radiation dosimetry providers. If approved it would be the first step toward applying the types of performance testing now required in personnel dosimetry to environmental radiation monitoring. The objective of this study was to pilot test the draft standard, before it undergoes final balloting, on a small group of dosimetry providers that were selected to provide a mix of facility types, thermoluminescent dosimeter designs and monitoring program applications. The first phase of the pilot test involved exposing dosimeters to laboratory photon, beta, and x-ray sources at routine and accident dose levels. In the second phase, dosimeters were subjected to ninety days of simulated environmental conditions in an environmental chamber that cycled through extremes of temperature and humidity. Two out of seven participants passed all categories of the laboratory testing phase, and all seven passed the environmental test phase. While some relatively minor deficiencies were uncovered in the course of the pilot test, the results show that draft N13.29 describes useful tests that could be appropriate for environmental dosimetry providers. An appendix to this report contains recommendations that should be addressed by the N13.29 working group before draft N13.29 is submitted for balloting

  19. Addendum to ''Test Plan: Small-Scale Seal Performance Tests (SSSPT)''

    International Nuclear Information System (INIS)

    Finley, R.E.

    1992-01-01

    This document describes activities that are intended to update the data base of fluid flow measurements made on expansive salt concrete (ESC) seals as part of the Small-Scale Seal Performance Tests (SSSPT). The original plans for the SSSPT experiments are described by Stormont (1985a and 1985b). These seals have previously been tested with brine and gas during the early stages (less than 450 days) after emplacement. The purpose of this Test Plan Addendum is to detail the activities necessary to, update the gas and brine measurements previously performed on the SSSPT Series A and Series B seals and to identify the key personnel responsible for implementing these activities. This addendum describes a limited undertaking and does NOT change the scope of the original test plan

  20. Acute Oxidative Effect and Muscle Damage after a Maximum 4 Min Test in High Performance Athletes.

    Directory of Open Access Journals (Sweden)

    Heros Ribeiro Ferreira

    Full Text Available The purpose of this investigation was to determine lipid peroxidation markers, physiological stress and muscle damage in elite kayakers in response to a maximum 4-min kayak ergometer test (KE test, and possible correlations with individual 1000m kayaking performances. The sample consisted of twenty-three adult male and nine adult female elite kayakers, with more than three years' experience in international events, who voluntarily took part in this study. The subjects performed a 10-min warm-up, followed by a 2-min passive interval, before starting the test itself, which consisted of a maximum 4-min work paddling on an ergometer; right after the end of the test, an 8 ml blood sample was collected for analysis. 72 hours after the test, all athletes took part in an official race, when then it was possible to check their performance in the on site K1 1000m test (P1000m. The results showed that all lipoproteins and hematological parameters tested presented a significant difference (p≤0.05 after exercise for both genders. In addition, parameters related to muscle damage such as lactate dehydrogenase (LDH and creatine kinase (CK presented significant differences after stress. Uric acid presented an inverse correlation with the performance (r = -0.76, while CK presented a positive correlation (r = 0.46 with it. Based on these results, it was possible to verify muscle damage and the level of oxidative stress caused by indoor training with specific ergometers for speed kayaking, highlighting the importance of analyzing and getting to know the physiological responses to this type of training, in order to provide information to coaches and optimize athletic performance.

  1. Carbohydrate ingestion improves performance of a new reliable test of soccer performance.

    Science.gov (United States)

    Currell, Kevin; Conway, Steve; Jeukendrup, Asker E

    2009-02-01

    The aim of the study was to investigate the reliability of a new test of soccer performance and evaluate the effect of carbohydrate (CHO) on soccer performance. Eleven university footballers were recruited and underwent 3 trials in a randomized order. Two of the trials involved ingesting a placebo beverage, and the other, a 7.5% maltodextrin solution. The protocol comprised a series of ten 6-min exercise blocks on an outdoor Astroturf pitch, separated by the performance of 2 of the 4 soccer-specific tests, making the protocol 90 min in duration. The intensity of the exercise was designed to be similar to the typical activity pattern during soccer match play. Participants performed skill tests of dribbling, agility, heading, and shooting throughout the protocol. The coefficients of variation for dribbling, agility, heading, and shooting were 2.2%, 1.2%, 7.0%, and 2.8%, respectively. The mean combined placebo scores were 42.4 +/- 2.7 s, 43.1 +/- 3.7 s, 210 +/- 34 cm, and 212 +/- 17 points for agility, dribbling, heading, and kicking, respectively. CHO ingestion led to a combined agility time of 41.5 +/- 0.8 s, for dribbling 41.7 +/- 3.5 s, 213 +/- 11 cm for heading, and 220 +/- 5 points for kicking accuracy. There was a significant improvement in performance for dribbling, agility, and shooting (p soccer performance, and ingesting CHO leads to an improvement in soccer performance.

  2. INVITATION TO PERFORM Y2K TESTING UNDER UNIX

    CERN Multimedia

    CERN Y2K Co-ordinator

    1999-01-01

    IntroductionA special AFS cell Ôy2k.cern.chÕ has been established to allow service managers and users to test y2k compliance.In addition to AFS, the cluster consists of machines representing all the Unix flavours in use at CERN (AIX, DUNIX, HP-UX, IRIX, LINUX, and SOLARIS).More information can be obtained from the page: http://wwwinfo.cern.ch/pdp/bis/y2k/y2kplus.htmlTesting scheduleThe cluster will be set to 25 December 1999 on fixed days and then left running for three weeks. This gives people one week to prepare test programs in 1999 and two weeks to check the consequences of passing into year 2000. These fixed dates are set as follows:— 19 May 1999, date set to 25/12/99 (year 2000 starts on 26 May) — 9 June1999, date set to 25/12/99 (year 2000 starts on 16 June)— 30 June 1999, date set to 25/12/99 (year 2000 starts on 7 July)If more than these three sessions are needed an announcement will be made later. RegistrationThe following Web page should be used for r...

  3. Cold Test and Performance Evaluation of Prototype Cryoline-X

    Science.gov (United States)

    Shah, N.; Choukekar, K.; Kapoor, H.; Muralidhara, S.; Garg, A.; Kumar, U.; Jadon, M.; Dash, B.; Bhattachrya, R.; Badgujar, S.; Billot, V.; Bravais, P.; Cadeau, P.

    2017-12-01

    The multi-process pipe vacuum jacketed cryolines for the ITER project are probably world’s most complex cryolines in terms of layout, load cases, quality, safety and regulatory requirements. As a risk mitigation plan, design, manufacturing and testing of prototype cryoline (PTCL) was planned before the approval of final design of ITER cryolines. The 29 meter long PTCL consist of 6 process pipes encased by thermal shield inside Outer Vacuum Jacket of DN 600 size and carries cold helium at 4.5 K and 80 K. The global heat load limit was defined as 1.2 W/m at 4.5 K and 4.5 W/m at 80 K. The PTCL-X (PTCL for Group-X cryolines) was specified in detail by ITER-India and designed as well as manufactured by Air Liquide. PTCL-X was installed and tested at cryogenic temperature at ITER-India Cryogenic Laboratory in 2016. The heat load at 4.5 K and 80 K, estimated using enthalpy difference method, was found to be approximately 0.8 W/m at 4.5 K, 4.2 W/m at 80 K, which is well within the defined limits. Thermal shield temperature profile was also found to be satisfactory. Paper summarizes the cold test results of PTCL-X

  4. Validity of the German Version of the Continuous-Scale Physical Functional Performance 10 Test

    Directory of Open Access Journals (Sweden)

    Irene Härdi

    2017-01-01

    Full Text Available Background. The Continuous-Scale Physical Functional Performance 10 Test (CS-PFP 10 quantitatively assesses physical functional performance in older adults who have a broad range of physical functional ability. This study assessed the validity and reliability of the CS-PFP 10 German version. Methods. Forward-translations and backtranslations as well as cultural adaptions of the test were conducted. Participants were German-speaking Swiss community-dwelling adults aged 64 and older. Concurrent validity was assessed using Pearson correlation coefficients between CS-PFP 10 and gait velocity, Timed Up and Go Test, hand grip strength, SF-36 physical function domain, and Freiburger Physical Activity Questionnaire. Internal consistency was calculated by Cronbach’s alpha. Results. Backtranslation and cultural adaptions were accepted by the CS-PFP 10 developer. CS-PFP 10 total score and subscores (upper body strength, upper body flexibility, lower body strength, balance and coordination, and endurance correlated significantly with all measures of physical function tested. Internal consistency was high (Cronbach’s alpha 0.95–0.98. Conclusion. The CS-PFP 10 German version is valid and reliable for measuring physical functional performance in German-speaking Swiss community-dwelling older adults. Quantifying physical function is essential for clinical practice and research and provides meaningful insight into physical functional performance of older adults. This trial is registered with ClinicalTrials.gov NCT01539200.

  5. Memory for performance feedback :a test of three self- motivation theories

    OpenAIRE

    Donlin, Joanne Mac

    1990-01-01

    The current study tests the adequacy of three self-motive theories to predict recall of performance feedback, memory sensitivity, and ratings of perceived accuracy. Self-enhancement (Jones, 1973) predicts individuals are motivated to maintain their self-esteem. Individuals will therefore recall positive relative to negative feedback and will rate positive feedback as more accurate. Self-consistency theory (Swann, 1985) predicts individuals are motivated to maintain their self-conceptions. The...

  6. Testing of tactical performance in youth elite soccer.

    Science.gov (United States)

    Memmert, Daniel

    2010-01-01

    This is a twofold study with the goals of evaluating tactical oriented game test situations for 12-13-year old highly-talented soccer players and to analyze dynamic, intra-individual developments of the players. A cross-sectional design was carried in study 1, using game test situations to measure specific tactics and creative performance for 195 expert players. The results from five evaluation criteria show that both diagnostic instruments can be used for recording football-specific creativity and game intelligence in talented young players. They produced tactical indicators that can be described as objective and valid, exhibit a sufficient degree of differentiation and are easy to record. Study 2 uses a longitudinal design to present a dynamic performance diagnostic tool for analyzing intra-individual improvements of German Soccer Foundation talents according to football-specific creativity and game intelligence. The results with respect to divergent tactical thinking clearly show that very different change processes were observed in the German Soccer Foundation players. Finally, the practical implications for the training process are discussed on the basis of both studies. Key pointsWith game test situations it is possible to assess tactical performance as game intelligence and creativity objective, valid, with a sufficient degree of differentiation, and economically.The results with respect to game intelligence and creativity show that very different change processes were observed in the German Soccer Foundation players dependend on the bases (trainers).Current literature on tactics for school sports as well as for children's, youth and high performance soccer at the club level should place much more emphasis on individual and group-tactical requirements in soccer.

  7. Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Buttner, William J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hartmann, Kevin S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Schmidt, Kara [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cebolla, Rafeal O [Joint Research Centre, Petten, the Netherlands; Weidner, Eveline [Joint Research Centre, Petten, the Netherlands; Bonato, Christian [Joint Research Centre, Petten, the Netherlands

    2017-11-06

    Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of

  8. Performance test for prototype game for children with adhd

    Science.gov (United States)

    Bahana, R.; Gaol, F. L.; Wiguna, T.; Hendric, S. W. H. L.; Soewito, B.; Nugroho, E.; Dirgantoro, B. P.; Abdurachman, E.

    2018-03-01

    The gaming industry has become one of the fastest growing industries in the world. In recent years there have been several studies that have used games, especially computer-based ones to improve the executive function of children with Attention Deficit Hyperactivity Disorder (ADHD) especially in working memory improvements. There are still several obstacles in using computer-based games that have been circulating today in Indonesia. The aim of this research is to develop and create a prototype game that can be used to improve working memory of children with ADHD using Bahasa Indonesia. The prototype game application is a race game with matching colors and memory work tasks; developed using Construct2. Players will play as a driver, delivering certain fruits to specific homes with different colors. The game also included visuospatial tasks such as remembering the objects. For performance test, CPU utilization, average FPS and image memory usage has been tested in several browsers. In conclusion, the performance tests results show that the first type of the prototype game is good enough to be played in desktop or laptop.

  9. Calibration and performance testing of electronic personal dosimeters (EPD)

    International Nuclear Information System (INIS)

    Banaga, H.A.

    2008-04-01

    In modern radiation protection practices, active personal dosimeters are becoming absolutely necessary operational tools for satisfying the ALARA principle. The aim of this work was to carry out calibration and performance testing of ten electronic personal dosimeters (EPD) used for the individual monitoring. The EPDs were calibrated in terms of operation radiation protection quantity, personal dose equivalent, Hp (10). Calibrations were carried out at three of x-ray beam qualities described in ISO 4037 namely 60, 100 and 150 kV in addition to Cs-137 gamma ray quality. The calibrations were performed using polymethylmethacrylate (PMMA) phantom with dimensions 20*20*15 cm 3 . Conversion coefficient Hp (10)/K air for the phantom was also calculated. The response and linearity of the dosimeter at the specified energies were also tested. The EPDs tested showed that the calibration coefficient ranged from 0.60 to 1.31 and an equivalent response for the specified energies that ranged from 0.76 to 1.67. The study demonstrated the possibility of using non standard phantom for calibrating dosimeters used for individual monitoring. The dosimeters under study showed a good response in all energies except the response in quality 100 kV. The linearity of the dosimeters was within ±15%, with the exception of the quality 100 kV where this limit was exceeded.(Author)

  10. Characterisation of the hydraulic properties within the EDZ around drifts at level -490 m of the Meuse/Haute-Marne URL: A methodology for consistent interpretation of hydraulic tests

    Science.gov (United States)

    Baechler, S.; Lavanchy, J. M.; Armand, G.; Cruchaudet, M.

    In order to investigate potential changes of the hydraulic properties of the EDZ over time in the Meuse/Haute-Marne underground research laboratory (URL), several hydraulic tests campaigns have been carried out between 2005 and 2008 in dedicated boreholes. After several test series, inconsistencies were noticed in the results, indicating, in particular cases, erratic, inexplicable property changes over time and spatial contrasts. It was therefore difficult to determine reliably potential trends of the EDZ hydraulic properties. It appeared necessary to re-evaluate both the interpretation concepts and assumptions applied to the numerical analyses of test data on the EDZ, trying to better constrain the flow model and the parameter variables. In order to improve the understanding of the geometrical, geomechanical and hydraulic properties of the EDZ, independent information from other investigation methods has been used to critically revise the conceptual model and formation parameters. In particular, results from a diffusion experiment and ultrasonic measurements allowed constraining the extent of the mechanical damaged zone around the borehole (BDZ). Storativity parameters were fitted due to their expected variability. Indeed, high storativity values can be presumed under the unsaturated conditions of the EDZ. The results of the reanalyses, performed with the numerical borehole simulator MULTISIM, demonstrated the good quality and consistency of the revised conceptual model with constrained BDZ and variable storativity. Overall the new simulation results obtained from selected test series are now very consistent. The revised conceptual model demonstrated its capacity to better represent the evolution and extension of the EDZ around a drift in Meuse/Haute-Marne URL. Further consistency checks are proposed to confirm the new model assumptions and the estimates of the single phase flow model in the EDZ.

  11. Characterisation of the hydraulic properties within the EDZ around drifts at level -490 m of the Meuse/Haute-Marne URL: A methodology for consistent interpretation of hydraulic tests

    International Nuclear Information System (INIS)

    Baechler, S.; Lavanchy, J. M.; Armand, G.; Cruchaudet, M.

    2011-01-01

    In order to investigate potential changes of the hydraulic properties of the EDZ over time in the Meuse/Haute-Marne underground research laboratory (URL), several hydraulic tests campaigns have been carried out between 2005 and 2008 in dedicated boreholes. After several test series, inconsistencies were noticed in the results, indicating, in particular cases, erratic, inexplicable property changes over time and spatial contrasts. It was therefore difficult to determine reliably potential trends of the EDZ hydraulic properties. It appeared necessary to re-evaluate both the interpretation concepts and assumptions applied to the numerical analyses of test data on the EDZ, trying to better constrain the flow model and the parameter variables. In order to improve the understanding of the geometrical, geomechanical and hydraulic properties of the EDZ, independent information from other investigation methods has been used to critically revise the conceptual model and formation parameters. In particular, results from a diffusion experiment and ultrasonic measurements allowed constraining the extent of the mechanical damaged zone around the borehole (BDZ). Storativity parameters were fitted due to their expected variability. Indeed, high storativity values can be presumed under the unsaturated conditions of the EDZ. The results of the reanalyses, performed with the numerical borehole simulator MULTISIM, demonstrated the good quality and consistency of the revised conceptual model with constrained BDZ and variable storativity. Overall the new simulation results obtained from selected test series are now very consistent. The revised conceptual model demonstrated its capacity to better represent the evolution and extension of the EDZ around a drift in Meuse/Haute-Marne URL. Further consistency checks are proposed to confirm the new model assumptions and the estimates of the single phase flow model in the EDZ. (authors)

  12. Performance verification tests of JT-60SA CS model coil

    Energy Technology Data Exchange (ETDEWEB)

    Obana, Tetsuhiro, E-mail: obana.tetsuhiro@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Murakami, Haruyuki [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan); Takahata, Kazuya; Hamaguchi, Shinji; Chikaraishi, Hirotaka; Mito, Toshiyuki; Imagawa, Shinsaku [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Kizu, Kaname; Natsume, Kyohei; Yoshida, Kiyoshi [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)

    2015-11-15

    Highlights: • The performance of the JT-60SA CS model coil was verified. • The CS model coil comprised a quad-pancake wound with a Nb{sub 3}Sn CIC conductor. • The CS model coil met the design requirements. - Abstract: As a final check of the coil manufacturing method of the JT-60 Super Advanced (JT-60SA) central solenoid (CS), we verified the performance of a CS model coil. The model coil comprised a quad-pancake wound with a Nb{sub 3}Sn cable-in-conduit conductor. Measurements of the critical current, joint resistance, pressure drop, and magnetic field were conducted in the verification tests. In the critical-current measurement, the critical current of the model coil coincided with the estimation derived from a strain of −0.62% for the Nb{sub 3}Sn strands. As a result, critical-current degradation caused by the coil manufacturing process was not observed. The results of the performance verification tests indicate that the model coil met the design requirements. Consequently, the manufacturing process of the JT-60SA CS was established.

  13. Exercise testing and hemodynamic performance in healthy elderly persons

    International Nuclear Information System (INIS)

    Hitzhusen, J.C.; Hickler, R.B.; Alpert, J.S.; Doherty, P.W.

    1984-01-01

    To determine the effect of age on cardiovascular performance, 39 healthy elderly men and women, 70 to 83 years old, underwent treadmill thallium-201 exercise perfusion imaging and radionuclide equilibrium angiography at rest and during supine bicycle exercise. Five volunteers who had a positive exercise thallium test response were excluded from the study. Radionuclide left ventricular ejection fraction, regional wall abnormalities, relative cardiac output, stroke volume, end-diastolic volume and end-systolic volume were measured. Seventy-four percent of the subjects maintained or increased their ejection fraction with exercise. With peak exercise, mean end-diastolic volume did not change, end-systolic volume decreased and cardiac output and stroke volume increased. Moreover, in 35% of the subjects, minor regional wall motion abnormalities developed during exercise. There was no significant difference in the response of men and women with regard to these variables. However, more women than men had difficulty performing bicycle ergometry because they had never bicycled before. Subjects who walked daily performed the exercise tests with less anxiety and with a smaller increase in heart rate and systolic blood pressure

  14. Performance norms for a rhesus monkey neuropsychological testing battery: acquisition and long-term performance.

    Science.gov (United States)

    Weed, M R; Taffe, M A; Polis, I; Roberts, A C; Robbins, T W; Koob, G F; Bloom, F E; Gold, L H

    1999-10-25

    A computerized behavioral battery based upon human neuropsychological tests (CANTAB, CeNeS, Cambridge, UK) has been developed to assess cognitive behaviors of rhesus monkeys. Monkeys reliably performed multiple tasks, providing long-term assessment of changes in a number of behaviors for a given animal. The overall goal of the test battery is to characterize changes in cognitive behaviors following central nervous system (CNS) manipulations. The battery addresses memory (delayed non-matching to sample, DNMS; spatial working memory, using a self-ordered spatial search task, SOSS), attention (intra-/extra-dimensional shift, ID/ED), motivation (progressive-ratio, PR), reaction time (RT) and motor coordination (bimanual task). As with human neuropsychological batteries, different tasks are thought to involve different neural substrates, and therefore performance profiles should assess function in particular brain regions. Monkeys were tested in transport cages, and responding on a touch sensitive computer monitor was maintained by food reinforcement. Parametric manipulations of several tasks demonstrated the sensitivity of performance to increases in task difficulty. Furthermore, the factors influencing difficulty for rhesus monkeys were the same as those shown to affect human performance. Data from this study represent performance of a population of healthy normal monkeys that will be used for comparison in subsequent studies of performance following CNS manipulations such as infection with simian immunodeficiency virus (NeuroAIDS) or drug administration.

  15. Performance testing of waste forms in a tuff environment

    International Nuclear Information System (INIS)

    Oversby, V.M.

    1983-11-01

    This paper describes experimental work conducted to establish the chemical composition of water which will have reacted with Topopah Spring Member tuff prior to contact with waste packages. The experimental program to determine the behavior of spent fuel and borosilicate glass in the presence of this water is then described. Preliminary results of experiments using spent fuel segments with defects in the Zircaloy cladding are presented. Some results from parametric testing of a borosilicate glass with tuff and 304L stainless steel are also discussed. Experiments conducted using Topopah Spring tuff and J-13 well water have been conducted to provide an estimate of the post-emplacement environment for waste packages in a repository at Yucca Mountain. The results show that emplacement of waste packages should cause only small changes in the water chemistry and rock mineralogy. The changes in environment should not have any detrimental effects on the performance of metal barriers or waste forms. The NNWSI waste form testing program has provided preliminary results related to the release rate of radionuclides from the waste package. Those results indicate that release rates from both spent fuel and borosilicate glass should be below 1 part in 10 5 per year. Future testing will be directed toward making release rate testing more closely relevant to site specific conditions. 17 references, 7 figures

  16. Design and Performance Test of Locking Curved-Nut

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Min Cheol; Kang, Ho Sung; Kim, Do Yeop; Lee, Suk Yong; Lee, Eung Suk [Chungbuk Nat’l Univ., Cheongju (Korea, Republic of); Jeong, Hui Jong [Viblock Company, Cheongwon (Korea, Republic of)

    2017-03-15

    Many types of locking nut are commercializing in the various industries where has heavy vibration. Because Nut's loosing causes a serious accident. But the most locking nuts are too expensive as the complicate manufacturing process. In this study, we design the new type of locking nut, 'Curved-Nut' that is relatively simple making process. We study a relation between the elastic energy and the nut loosing mechanism. So it is analysed, the elastic energy of Curved-Nut comparing with the locking test. The Curved-Nut was manufactured on the commercial nut using a milling tool with horizontal cutting, one or two time under the nut. As the result, the more elastic energy the more prevent the loosing of the nut. We verified the performance of the loosing nut using the vibration testing equipment (NAS3350).

  17. BWR spent fuel storage cask performance test. Volume 1. Cask handling experience and decay heat, heat transfer, and shielding data

    International Nuclear Information System (INIS)

    McKinnon, M.A.; Doman, J.W.; Tanner, J.E.; Guenther, R.J.; Creer, J.M.; King, C.E.

    1986-02-01

    This report documents a heat transfer and shielding performance test conducted on a Ridihalgh, Eggers and Associates REA 2023 boiling water reactor (BWR) spent fuel storage cask. The testing effort consisted of three parts: pretest preparations, performance testing, and post-test activities. Pretest preparations included conducting cask handling dry runs and characterizing BWR spent fuel assemblies from Nebraska Public Power District's Cooper Nuclear Station. The performance test matrix included 14 runs consisting of two loadings, two cask orientations, and three backfill environments. Post-test activities included calorimetry and axial radiation scans of selected fuel assemblies, in-basin sipping of each assembly, crud collection, video and photographic scans, and decontamination of the cask interior and exterior

  18. A Modified T-Test for Football Referees to Test Agility, Quickness and Sprint Performances

    Science.gov (United States)

    Muniroglu, S.; Subak, E.

    2018-01-01

    The football referees perform many actions as jogging, running, sprinting, side steps and backward steps during a football match. Further, the football referees change match activities every 5-6 seconds. Many tests are being conducted to determine the physical levels and competences of football referees like 50 m running, 200 m running, 12 minutes…

  19. AULA virtual reality test as an attention measure: convergent validity with Conners' Continuous Performance Test.

    Science.gov (United States)

    Díaz-Orueta, Unai; Garcia-López, Cristina; Crespo-Eguílaz, Nerea; Sánchez-Carpintero, Rocío; Climent, Gema; Narbona, Juan

    2014-01-01

    The majority of neuropsychological tests used to evaluate attention processes in children lack ecological validity. The AULA Nesplora (AULA) is a continuous performance test, developed in a virtual setting, very similar to a school classroom. The aim of the present study is to analyze the convergent validity between the AULA and the Continuous Performance Test (CPT) of Conners. The AULA and CPT were administered correlatively to 57 children, aged 6-16 years (26.3% female) with average cognitive ability (IQ mean = 100.56, SD = 10.38) who had a diagnosis of attention deficit/hyperactivity disorder (ADHD) according to DSM-IV-TR criteria. Spearman correlations analyses were conducted among the different variables. Significant correlations were observed between both tests in all the analyzed variables (omissions, commissions, reaction time, and variability of reaction time), including for those measures of the AULA based on different sensorial modalities, presentation of distractors, and task paradigms. Hence, convergent validity between both tests was confirmed. Moreover, the AULA showed differences by gender and correlation to Perceptual Reasoning and Working Memory indexes of the WISC-IV, supporting the relevance of IQ measures in the understanding of cognitive performance in ADHD. In addition, the AULA (but not Conners' CPT) was able to differentiate between ADHD children with and without pharmacological treatment for a wide range of measures related to inattention, impulsivity, processing speed, motor activity, and quality of attention focus. Additional measures and advantages of the AULA versus Conners' CPT are discussed.

  20. The Impact of Couple HIV Testing and Counseling on Consistent Condom Use Among Pregnant Women and Their Male Partners: An Observational Study.

    Science.gov (United States)

    Rosenberg, Nora E; Graybill, Lauren A; Wesevich, Austin; McGrath, Nuala; Golin, Carol E; Maman, Suzanne; Bhushan, Nivedita; Tsidya, Mercy; Chimndozi, Limbikani; Hoffman, Irving F; Hosseinipour, Mina C; Miller, William C

    2017-08-01

    In sub-Saharan Africa couple HIV testing and counseling (CHTC) has been associated with substantial increases in safe sex, especially when at least one partner is HIV infected. However, this relationship has not been characterized in an Option B+ context. The study was conducted at the antenatal clinic at Bwaila District Hospital in Lilongwe, Malawi in 2016 under an Option B+ program. Ninety heterosexual couples with an HIV-infected pregnant woman (female-positive couples) and 47 couples with an HIV-uninfected pregnant woman (female-negative couples) were enrolled in an observational study. Each couple member was assessed immediately before and 1 month after CHTC for safe sex (abstinence or consistent condom use in the last month). Generalized estimating equations were used to model change in safe sex before and after CHTC and to compare safe sex between female-positive and female-negative couples. Mean age was 26 years among women and 32 years among men. Before CHTC, safe sex was comparable among female-positive couples (8%) and female-negative couples (2%) [risk ratio (RR): 3.7, 95% confidence interval (CI): 0.5 to 29.8]. One month after CHTC, safe sex was higher among female-positive couples (75%) than among female-negative couples (3%) (RR: 30.0, 95% CI: 4.3 to 207.7). Safe sex increased substantially after CTHC for female-positive couples (RR 9.6, 95% CI: 4.6 to 20.0), but not for female-negative couples (RR: 1.2, 95% CI: 0.1 to 18.7). Engaging pregnant couples in CHTC can have prevention benefits for couples with an HIV-infected pregnant woman, but additional prevention approaches may be needed for couples with an HIV-uninfected pregnant woman.

  1. Performance testing of a small vertical-axis wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, R.; Tullis, S.; Ziada, S. [McMaster Univ., Hamilton, ON (Canada). Dept. of Mechanical Engineering

    2007-07-01

    Full-scale wind tunnel testing of a prototype 3.5 kW vertical-axis wind turbine (VAWT) was conducted in a low speed wind tunnel in Ottawa. The tests were conducted to determine nominal power curves as well as the system's structural integrity, safety and operational characteristics. Dimensionless power curves were used to assess the relation between the wind turbine's rotary speed and the produced power for various wind speeds. Tests began at the lowest wind speed and revolutions per minute (RPM) and were gradually increased. A proximity sensor was used to determine the passing frequency of spaced bolts. The aerodynamic performance of the turbine was evaluated using a servo-controlled mechanical variable load with a disc brake calliper and electro-hydraulic servo-actuator. A load cell was used to measure torque produced by the turbine. An active closed loop speed control system was used to regulate the rotary speed of the turbine. The system used a high gain proportional control law to guarantee stability. Calculated power was based on the average rotary speed measurement. Results of the study suggested that the dimensional power performance of the turbine could be predicted from the curve for all rotary speeds and for wind speeds between 8 and 16 m/s. The maximum power coefficient of 0.3 occurred at a tip speed ratio of 1.6. Test results demonstrated that the turbine reached its rated power at 14 m/s. However, the range of tip speed ratios for power production were lower than the range for most other small VAWT. 2 refs., 3 figs.

  2. The VUV instrument SPICE for Solar Orbiter: performance ground testing

    Science.gov (United States)

    Caldwell, Martin E.; Morris, Nigel; Griffin, Douglas K.; Eccleston, Paul; Anderson, Mark; Pastor Santos, Carmen; Bruzzi, Davide; Tustain, Samuel; Howe, Chris; Davenne, Jenny; Grundy, Timothy; Speight, Roisin; Sidher, Sunil D.; Giunta, Alessandra; Fludra, Andrzej; Philippon, Anne; Auchere, Frederic; Hassler, Don; Davila, Joseph M.; Thompson, William T.; Schuehle, Udo H.; Meining, Stefan; Walls, Buddy; Phelan, P.; Dunn, Greg; Klein, Roman M.; Reichel, Thomas; Gyo, Manfred; Munro, Grant J.; Holmes, William; Doyle, Peter

    2017-08-01

    SPICE is an imaging spectrometer operating at vacuum ultraviolet (VUV) wavelengths, 70.4 - 79.0 nm and 97.3 - 104.9 nm. It is a facility instrument on the Solar Orbiter mission, which carries 10 science instruments in all, to make observations of the Sun's atmosphere and heliosphere, at close proximity to the Sun, i.e to 0.28 A.U. at perihelion. SPICE's role is to make VUV measurements of plasma in the solar atmosphere. SPICE is designed to achieve spectral imaging at spectral resolution >1500, spatial resolution of several arcsec, and two-dimensional FOV of 11 x16arcmins. The many strong constraints on the instrument design imposed by the mission requirements prevent the imaging performance from exceeding those of previous instruments, but by being closer to the sun there is a gain in spatial resolution. The price which is paid is the harsher environment, particularly thermal. This leads to some novel features in the design, which needed to be proven by ground test programs. These include a dichroic solar-transmitting primary mirror to dump the solar heat, a high in-flight temperature (60deg.C) and gradients in the optics box, and a bespoke variable-line-spacing grating to minimise the number of reflective components used. The tests culminate in the systemlevel test of VUV imaging performance and pointing stability. We will describe how our dedicated facility with heritage from previous solar instruments, is used to make these tests, and show the results, firstly on the Engineering Model of the optics unit, and more recently on the Flight Model. For the keywords, select up to 8 key terms for a search on your manuscript's subject.

  3. Alternate performance standard project: Interpreting the post-construction test

    International Nuclear Information System (INIS)

    Williamson, A.D.; McDonough, S.E.

    1993-01-01

    The paper describes the results of a project commissioned by the State of Florida, in cooperation with the US Environmental Protection Agency, as one portion of the Florida Radon Research Program (FRRP). The purpose of the FRRP is to provide technical support for a statewide Building Standard for Radon-Resistant Construction currently in the rulemaking process. In this case the information provides technical background for a post-construction radon test specified as a performance element of the code which accompanies the prescriptive alternative that does not incorporate active radon reduction systems

  4. Performance testing of thermal analysis codes for nuclear fuel casks

    International Nuclear Information System (INIS)

    Sanchez, L.C.

    1987-01-01

    In 1982 Sandia National Laboratories held the First Industry/Government Joint Thermal and Structural Codes Information Exchange and presented the initial stages of an investigation of thermal analysis computer codes for use in the design of nuclear fuel shipping casks. The objective of the investigation was to (1) document publicly available computer codes, (2) assess code capabilities as determined from their user's manuals, and (3) assess code performance on cask-like model problems. Computer codes are required to handle the thermal phenomena of conduction, convection and radiation. Several of the available thermal computer codes were tested on a set of model problems to assess performance on cask-like problems. Solutions obtained with the computer codes for steady-state thermal analysis were in good agreement and the solutions for transient thermal analysis differed slightly among the computer codes due to modeling differences

  5. WIPP [Waste Isolation Pilot Plant] test phase plan: Performance assessment

    International Nuclear Information System (INIS)

    1990-04-01

    The U.S. Department of Energy (DOE) is responsible for managing the disposition of transuranic (TRU) wastes resulting from nuclear weapons production activities of the United States. These wastes are currently stored nationwide at several of the DOE's waste generating/storage sites. The goal is to eliminate interim waste storage and achieve environmentally and institutionally acceptable permanent disposal of these TRU wastes. The Waste Isolation Pilot Plant (WIPP) in southeastern New Mexico is being considered as a disposal facility for these TRU wastes. This document describes the first of the following two major programs planned for the Test Phase of WIPP: Performance Assessment -- determination of the long-term performance of the WIPP disposal system in accordance with the requirements of the EPA Standard; and Operations Demonstration -- evaluation of the safety and effectiveness of the DOE TRU waste management system's ability to emplace design throughput quantities of TRU waste in the WIPP underground facility. 120 refs., 19 figs., 8 tabs

  6. Testing of camera performance standards at steady and local overloading

    International Nuclear Information System (INIS)

    Keszthelyine Landori, S.; Adorjanne Farkas, M.; Csirik, J.

    1983-01-01

    Camera performance standards are usually given for low count rates and uniform irradiation. A conventional analog gamma camera system (Gamma MB 9100 manufactured under the know-how of Picker DC 4/12 in Hungary) was studied on the basis of the Picker test procedure and the NEMA standard system. Uniformity, linearity, spatial and energy resolution were measured at high count rates and uniform irradiation (steady overloading). Linearity was studied at local overloading. Linearity, spatial and energy resolution were measured by a 1024-channel analyzer-computer system of KFKI, Hungary. The data were evaluated on the basis of NEMA standards, while uniformity was measured by the Gamma data processing system and evaluated by special SEGAMS programs. Performance variations were studied between 7500 cps and 75.000 cps pulse rates. Spatial and energy resolution were influenced strongly, uniformity slightly by pulse rates, while linearity did not change at all. Linearity was not influenced even by local overloading. (author)

  7. Castor-V/21 PWR spent fuel storage cask performance test

    International Nuclear Information System (INIS)

    Creer, J.M.; Schoonen, D.H.

    1986-01-01

    Performance testing of a CASTOR-V/21 PWR spent fuel storage cask manufactured by Gesellschaft fur Nuklear Service (GNS) was performed as part of a cooperative program between Virginia Power and the US Department of Energy. The performance test consisted of obtaining cask handling experience and heat transfer, shielding, and limited fuel integrity data. Five heat transfer test runs were performed with 21 Surry reactor spent fuel assemblies generating approximately 28 kW. Test runs were performed vacuum, nitrogen, and helium backfill environments with the cask in both vertical and horizontal orientations. Cask exterior surface gamma and neutron dose rates were measured with the cask fully loaded. Gas samples were obtained at the beginning and end of each run with nitrogen or helium environments to verify fuel integrity. The heat transfer performance of the CASTOR-V/21 cask was exceptionally good. Peak clad temperatures with helium and nitrogen environments with the cask in a vertical orientation and with helium with the cask in a horizontal orientation were less than 380 0 C. Vertical vacuum and horizontal nitrogen test runs resulted in peak clad temperatures over 380 0 , but the temperatures were not excessively high ( 0 C). The shielding performance of the cask met the design goal of less than 200 mrem/hr. Cask surface dose rates of <75 mrem/hr can easily be established with minor gamma shielding design refinements if desired. Gas samples obtained during testing indicated no leaking fuel rods were present in the cask. It was concluded that the cask performed satisfactorily from heat transfer and shielding perspectives

  8. Test set up description and performances for HAWAII-2RG detector characterization at ESTEC

    Science.gov (United States)

    Crouzet, P.-E.; ter Haar, J.; de Wit, F.; Beaufort, T.; Butler, B.; Smit, H.; van der Luijt, C.; Martin, D.

    2012-07-01

    In the frame work of the European Space Agency's Cosmic Vision program, the Euclid mission has the objective to map the geometry of the Dark Universe. Galaxies and clusters of galaxies will be observed in the visible and near-infrared wavelengths by an imaging and spectroscopic channel. For the Near Infrared Spectrometer instrument (NISP), the state-of-the-art HAWAII-2RG detectors will be used, associated with the SIDECAR ASIC readout electronic which will perform the image frame acquisitions. To characterize and validate the performance of these detectors, a test bench has been designed, tested and validated. This publication describes the pre-tests performed to build the set up dedicated to dark current measurements and tests requiring reasonably uniform light levels (such as for conversion gain measurements). Successful cryogenic and vacuum tests on commercial LEDs and photodiodes are shown. An optimized feed through in stainless steel with a V-groove to pot the flex cable connecting the SIDECAR ASIC to the room temperature board (JADE2) has been designed and tested. The test set up for quantum efficiency measurements consisting of a lamp, a monochromator, an integrating sphere and set of cold filters, and which is currently under construction will ensure a uniform illumination across the detector with variations lower than 2%. A dedicated spot projector for intra-pixel measurements has been designed and built to reach a spot diameter of 5 μm at 920nm with 2nm of bandwidth [1].

  9. Individual differences in infant fearfulness and cognitive performance: a testing, performance, or competence effect?

    Science.gov (United States)

    Rieser-Danner, Loretta A

    2003-02-01

    The author conducted 2 studies to examine the relations between infant fear and cognitive testing performance in 12-month-old infants. In Study 1, fear was assessed by using 2 standard temperament questionnaires and a laboratory-based, standardized stranger approach. Individual differences in cognitive development were assessed using the Object Permanence Scale of the Infant Psychological Development Scales (I. C. Uzgiris & J. M. Hunt, 1975). All 3 assessments of fear significantly predicted object permanence performance, with correlations ranging from -.32 to -.35. In Study 2, fear was assessed via a maternal report questionnaire, and habituation performance was assessed via a basic-level categorization task. Familiarity with the examiner and with the testing environment was manipulated to test for a familiarity influence on performance. Testing revealed individual differences in both fear and habituation. Results suggest that highly fearful infants required more trials to habituate and were less likely to meet the habituation criterion than infants who were less fearful. Methodological and conceptual implications of these results are discussed.

  10. The development and performance testing of a biodegradable scale inhibitor

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, Julie; Fidoe, Steve; Jones, Chris

    2006-03-15

    The oil industry is currently facing severe restrictions concerning the discharge of oil field chemicals into the environment. Many commonly used materials in both topside and downhole applications are phased for substitution for use in the North Sea, and more will be identified. The development of biodegradable and low toxicity chemicals, which afford equal or improved efficacy, compared to conventional technology, available at a competitive price, is a current industry challenge. A range of biodegradable materials are increasingly available, however their limited performance can result in a restricted range of applications. This paper discusses the development and commercialization of a readily biodegradable scale inhibitor, ideal for use in topside applications. This material offers a broad spectrum of activity, notably efficiency against barium sulphate, calcium sulphate and calcium carbonate scales, in a range of water chemistries. A range of performance testing, compatibility, stability and OCNS dataset will be presented. Comparisons with commonly used chemicals have been made to identify the superior performance of this phosphate ester. This paper will discuss a scale inhibitor suitable for use in a variety of conditions which offers enhanced performance combined with a favourable biodegradation profile. This material is of great benefit to the industry, particularly in North Sea applications. (author) (tk)

  11. Impression formation of tests: retrospective judgments of performance are higher when easier questions come first.

    Science.gov (United States)

    Jackson, Abigail; Greene, Robert L

    2014-11-01

    Four experiments are reported on the importance of retrospective judgments of performance (postdictions) on tests. Participants answered general knowledge questions and estimated how many questions they answered correctly. They gave higher postdictions when easy questions preceded difficult questions. This was true when time to answer each question was equalized and constrained, when participants were instructed not to write answers, and when questions were presented in a multiple-choice format. Results are consistent with the notion that first impressions predominate in overall perception of test difficulty.

  12. Performance test results of mock-up test facility of HTTR hydrogen production system

    International Nuclear Information System (INIS)

    Ohashi, Hirofumi; Inaba, Yoshitomo; Nishihara, Tetsuo

    2004-01-01

    For the purpose to demonstrate effectiveness of high-temperature nuclear heat utilization, Japan Atomic Energy Research Institute has been developing a hydrogen production system and has planned to connect the hydrogen production system to High Temperature Engineering Test Reactor (HTTR). Prior to construction of a HTTR hydrogen production system, a mock-up test facility was constructed to investigate transient behavior of the hydrogen production system and to establish system controllability. The Mock-up test facility with a full-scale reaction tube is an approximately 1/30-scale model of the HTTR hydrogen production system and an electric heater is used as a heat source instead of a reactor. After its construction, a performance test of the test facility was carried out in the same pressure and temperature conditions as those of the HTTR hydrogen production system to investigate its performance such as hydrogen production ability, controllability and so on. It was confirmed that hydrogen was stably produced with a hot helium gas about 120m 3 /h, which satisfy the design value, and thermal disturbance of helium gas during the start-up could be mitigated within the design value by using a steam generator. The mock-up test of the HTTR hydrogen production system using this facility will continue until 2004. (author)

  13. Tests Performed on Hydraulic Turbines at Commissioning or after Capital Repairs. Part II. Tests Performed on a 6.5 MW Kaplan Turbine

    Directory of Open Access Journals (Sweden)

    Adrian Cuzmoş

    2015-07-01

    Full Text Available The paper presents the tests performed on a hydraulic turbine on commissioning, the devices, test methods and the results obtained from the respective tests, as well as the conclusions and recommendations resulted from these tests. This kind of tests can be performed for the verification of guarantees.

  14. Personality and job performance: test of the mediating effects of motivation among sales representatives.

    Science.gov (United States)

    Barrick, Murray R; Stewart, Greg L; Piotrowski, Mike

    2002-02-01

    Research shows consistent relations between personality and job performance. In this study the authors develop and test a model of job performance that examines the mediating effects of cognitive-motivational work orientations on the relationships between personality traits and performance in a sales job (N = 164). Covariance structural analyses revealed proximal motivational variables to be influential mechanisms through which distal personality traits affect job performance. Specifically, striving for status and accomplishment mediate the effects of Extraversion and Conscientiousness on ratings of sales performance. Although Agreeableness was related to striving for communion, neither Agreeableness nor communion striving was related to success in this sales job. The importance of the proposed motivational orientations model is discussed.

  15. Tradução, adaptação e avaliação da consistência interna do Eating Behaviours and Body Image Test para uso com crianças do sexo feminino Translation, adaptation and internal consistency evaluation of the Eating Behaviours and Body Image Test for female children

    Directory of Open Access Journals (Sweden)

    Elizângela Moreira Careta Galindo

    2007-02-01

    Full Text Available Este trabalho tem por objetivo traduzir, adaptar e validar o Eating Behaviours and Body Image Test, para uso com crianças de uma cidade do interior do estado de São Paulo. Foram sujeitos do estudo 261 escolares do sexo feminino, na faixa etária de 9 a 12 anos. Por meio da análise fatorial, com rotação varimax avaliou-se a consistência interna do instrumento. Esta análise, realizada com o auxílio do programa Statistical Package for Social Sciences, versão 10.0, revelou dois fatores. Para o instrumento total a consistência interna foi adequada (coeficiente a de Cronbach: 0,89 e para os dois fatores (1 e 2 os valores de a também foram considerados satisfatórios (alfa=0,90 e alfa=0,80, respectivamente, mostrando, assim, que o Eating Behaviours and Body Image Test é útil para uma avaliação precoce, rastreando atitudes indicadoras de possíveis distúrbios no comportamento alimentar. Foram mantidas as características psicométricas do instrumento original.This study aimed to translate, adapt and validate the Eating Bahaviours and Body Image Test, to be used with children in a city in upstate São Paulo. Study subjects were 261 female students aging from 9 to 12 years. The internal consistency of the instrument was evaluated by means of factorial analysis with varimax rotation. This analysis was accomplished through Statistical Package for Social Sciences, version 10.0, revealing two factors. The internal consistency was adequate for the total instrument (Cronbach's alpha=0.89 and a values were also considered satisfactory for the two factors (1 and 2 (alpha=0.90 and alpha=0.80, respectively, which demonstrated that the Eating Bahaviours and Body Image Test is useful for an initial evaluation, tracing symptoms that indicate possible eating behavior disorders. The psychometric characteristics of the original instrument were maintained.

  16. Performance analysis in Japanese field test program; Field test data kara no chiiki hatsuden kaiseki hoho

    Energy Technology Data Exchange (ETDEWEB)

    Sugiyama, H.; Kurokawa, K.; Uchida, D. [Tokyo University of Agriculture and Technology, Tokyo (Japan); Otani, K.; Sakuta, K.; Tsuda, I. [Electrotechnical Laboratory, Tsukuba (Japan); Oshiro, T.; Sakamoto, K. [Japan Quality Assurance Organization, Tokyo (Japan)

    1997-11-25

    Power generation characteristics are investigated using data collected in photovoltaic power generation field tests being undertaken by NEDO (New Energy and Industrial Technology Development Organization). The photovoltaic power generation system performance is evaluated by examining loss factors leading to degradation in system performance, with weather conditions such as variation in insolation and air temperature, inverter performance, and shadows cast by surrounding buildings taken into consideration. As the result, it is found that the important loss factors are degradation in module performance due to elevated temperature, drift in the maximum output control, degraded inverter performance due to input power variation, effect of shadows, etc. It is learned that system is greatly affected by degradation in module performance due to increased temperature in summer and by shadows in winter, the two being responsible for the output coefficient dropping to approximately 75% throughout the year. The output coefficient frequency distribution charts for the 75 test sites confirm that the rate is as low as 70-80% at many sites. As for the system operating time, it tends to be longer in West Japan where the annual insolation rate is higher. 3 refs., 10 figs.

  17. Design and performance of beam test electronics for the PHENIX multiplicity vertex detector

    International Nuclear Information System (INIS)

    Britton, C.L. Jr.; Bryan, W.L.; Emery, M.S.

    1996-01-01

    The system architecture and test results of the custom circuits and beam test system for the Multiplicity-Vertex Detector (MVD) for the PHENIX detector collaboration at the Relativistic Heavy Ion Collider (RHIC) are presented in this paper. The final detector per-channel signal processing chain will consist of a preamplifier-gain stage, a current-mode summed multiplicity discriminator, a 64-deep analog memory (simultaneous read-write), a post-memory analog correlator, and a 10-bit 5 μs ADC. The Heap Manager provides all timing control, data buffering, and data formatting for a single 256-channel multi-chip module (MCM). Each chip set is partitioned into 32-channel sets. Beam test (16-cell deep memory) performance for the various blocks will be presented as well as the ionizing radiation damage performance of the 1.2 μ n-well CMOS process used for preamplifier fabrication

  18. Performance Test of BF3 Neutron Detection System

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yu Sun; Shin, Ho Cheol [KHNP-CRI, Daejeon (Korea, Republic of); Cho, Jin Bok; Oh, Sae Hyun; Ryou, Seok Jean [USERS, Daejeon (Korea, Republic of)

    2015-10-15

    The neutron detecting system of First-of-a-kind plant such an APR1400 at Shin Kori should have been verified in the condition of low operating temperature and pressure of the primary coolant system before receiving the operation license. Auxiliary Ex-core Neutron Flux Monitoring System (AENFMS) is supposed to be installed using BF3 neutron detector in Shin Kori plant. The performance test of AENFMS was conducted to measure neutron sensitivity, moderation ratio and count rate in the same condition with Ex-core Neutron Flux Monitoring System (ENFMS) of APR1400 to verify its detection characteristics in compliance with the functional requirement. Performance test has been conducted for AENFMS of APR1400 to verify BF3 neutron sensitivity, moderation ration of PE, expecting neutron signal count rate from AENFMS, possible extending cable length from detector to pre-amplifier. As a result of measurement, the neutron sensitivity of 34.246±0.168(95%CI)cps/nv, moderation ratio of 11.343±0.039(95%CI) and AENFMS expecting count rate related to ENFMS of 17.8 times are acceptable in compliance with functional requirement, respectively.

  19. Performance testing of 3D point cloud software

    Directory of Open Access Journals (Sweden)

    M. Varela-González

    2013-10-01

    Full Text Available LiDAR systems are being used widely in recent years for many applications in the engineering field: civil engineering, cultural heritage, mining, industry and environmental engineering. One of the most important limitations of this technology is the large computational requirements involved in data processing, especially for large mobile LiDAR datasets. Several software solutions for data managing are available in the market, including open source suites, however, users often unknown methodologies to verify their performance properly. In this work a methodology for LiDAR software performance testing is presented and four different suites are studied: QT Modeler, VR Mesh, AutoCAD 3D Civil and the Point Cloud Library running in software developed at the University of Vigo (SITEGI. The software based on the Point Cloud Library shows better results in the loading time of the point clouds and CPU usage. However, it is not as strong as commercial suites in working set and commit size tests.

  20. Do candidate reactions relate to job performance or affect criterion-related validity? A multistudy investigation of relations among reactions, selection test scores, and job performance.

    Science.gov (United States)

    McCarthy, Julie M; Van Iddekinge, Chad H; Lievens, Filip; Kung, Mei-Chuan; Sinar, Evan F; Campion, Michael A

    2013-09-01

    Considerable evidence suggests that how candidates react to selection procedures can affect their test performance and their attitudes toward the hiring organization (e.g., recommending the firm to others). However, very few studies of candidate reactions have examined one of the outcomes organizations care most about: job performance. We attempt to address this gap by developing and testing a conceptual framework that delineates whether and how candidate reactions might influence job performance. We accomplish this objective using data from 4 studies (total N = 6,480), 6 selection procedures (personality tests, job knowledge tests, cognitive ability tests, work samples, situational judgment tests, and a selection inventory), 5 key candidate reactions (anxiety, motivation, belief in tests, self-efficacy, and procedural justice), 2 contexts (industry and education), 3 continents (North America, South America, and Europe), 2 study designs (predictive and concurrent), and 4 occupational areas (medical, sales, customer service, and technological). Consistent with previous research, candidate reactions were related to test scores, and test scores were related to job performance. Further, there was some evidence that reactions affected performance indirectly through their influence on test scores. Finally, in no cases did candidate reactions affect the prediction of job performance by increasing or decreasing the criterion-related validity of test scores. Implications of these findings and avenues for future research are discussed. PsycINFO Database Record (c) 2013 APA, all rights reserved

  1. Relationship between the Handball-Specific Complex-Test and Intermittent Field Test performance in professional players.

    Science.gov (United States)

    Hermassi, Souhail; Hoffmeyer, Birgit; Irlenbusch, Lars; Fieseler, Georg; Noack, Frank; Delank, Karl-Stefan; Gabbett, Tim J; Souhaiel Chelly, Mohamed; Schwesig, René

    2018-01-01

    We investigated the relationship between the Handball Complex-Test (HBCT) and two selected field performance tests (the repeated sprint ability [RSA], and the Yo-Yo Intermittent Recovery Test) in elite handball players. Nineteen handball players (age: 25.7±5.1 years) were drawn from the First Professional German League. The HBCT consists of four activity series (AS): agility parcours, defensive action, sprint (10 m, 20 m) and throw-on-goal parcours; these activities were completed twice, with five active pauses of 30-35 s, and a follow-up of recovery over the subsequent 10 minutes. The RSA comprised 6 x (15+15 m) sprints starting every 20 s; scoring noted best time (RSAbest), total time (RSATT) and decrement (RSAdec). In the Yo-Yo Intermittent Recover, we recorded the total distance covered (TD). Heart rates (HR) were recorded throughout and recovery was assessed for measurements immediately post-test (R0) and 10 minutes after completing the test (R10). A strong correlation was found between HBCT and fastest 10 m and 20 m RSA sprint times (r=0.811, r=0.815, respectively). Also, the HBCT total 10 m and 20 m sprint times showed a strong positive association with RSATT (r=0.70; r=0.63, respectively), and the RSA heart rate post-test was strongly correlated with the HBCT heart rate after round two (r=0.865). Data from the match-specific HBCT Test shows a strong positive association with other more generic intermittent field test measurements. These observations support the validity of using the generic tests to monitor current fitness and responses to training in team handball players.

  2. A Universal Motor Performance Test System Based on Virtual Instrument

    Directory of Open Access Journals (Sweden)

    Wei Li

    2014-09-01

    Full Text Available With the development of technology universal motors play a more and more important role in daily life and production, they have been used in increasingly wide field and the requirements increase gradually. How to control the speed and monitor the real-time temperature of motors are key issues. The cost of motor testing system based on traditional technology platform is very high in many reasons. In the paper a universal motor performance test system which based on virtual instrument is provided. The system achieves the precise control of the current motor speed and completes the measurement of real-time temperature of motor bearing support in order to realize the testing of general-purpose motor property. Experimental result shows that the system can work stability in controlling the speed and monitoring the real-time temperature. It has advantages that traditional using of SCM cannot match in speed, stability, cost and accuracy aspects. Besides it is easy to expand and reconfigure.

  3. Evaluation and modelling of SWIW tests performed within the SKB site characterisation programme

    International Nuclear Information System (INIS)

    Nordqvist, Rune

    2008-08-01

    In this report, a comprehensive overview of SWIW (Single Well Injection-Withdrawal) tests carried out within the SKB site investigations at Oskarshamn and Forsmark is presented. The purpose of this study is to make a general review and a comparison of performed SWIW tests within the site investigation programmes at the two sites. The study summarises experimental conditions for each test and discusses factors that may influence the experimental results and evaluation of the tests. Further, an extended model evaluation is carried out using a one- dimensional radial flow and transport model with matrix diffusion and matrix sorption. The intended outcome is an improved understanding of various mechanisms that may influence the SWIW test results and also to improve interpretation of the tests. Six SWIW test at each site have been carried out, generally resulting in high-quality and well documented experimental data with high tracer recovery. The tests have been performed in surface boreholes at repository depth, ranging approximately between 300 to 700 m borehole lengths. In all of the tests, a non-sorbing tracer (Uranine) and one or two sorbing tracers (cesium and rubidium) have been used simultaneously. A general result is that all of the tests demonstrate a very clear and relatively large retardation effect for the sorbing tracers. Basic initial modelling of the SWIW tests data, using a one-dimensional radial flow model with advection and dispersion, generally resulted in relatively good agreement between model and experimental data. However, a consistent feature of the initial modelling was a discrepancy between model and experimental data in the later parts of the recovery tracer breakthrough curve. It was concluded that this likely was caused by processes occurring in the tested rock formation and therefore an extended model evaluation (presented in this report) including matrix diffusion was carried out on all of the performed tests. Evaluated retardation

  4. Evaluation and modelling of SWIW tests performed within the SKB site characterisation programme

    Energy Technology Data Exchange (ETDEWEB)

    Nordqvist, Rune (Geosigma AB, Uppsala (SE))

    2008-08-15

    In this report, a comprehensive overview of SWIW (Single Well Injection-Withdrawal) tests carried out within the SKB site investigations at Oskarshamn and Forsmark is presented. The purpose of this study is to make a general review and a comparison of performed SWIW tests within the site investigation programmes at the two sites. The study summarises experimental conditions for each test and discusses factors that may influence the experimental results and evaluation of the tests. Further, an extended model evaluation is carried out using a one- dimensional radial flow and transport model with matrix diffusion and matrix sorption. The intended outcome is an improved understanding of various mechanisms that may influence the SWIW test results and also to improve interpretation of the tests. Six SWIW test at each site have been carried out, generally resulting in high-quality and well documented experimental data with high tracer recovery. The tests have been performed in surface boreholes at repository depth, ranging approximately between 300 to 700 m borehole lengths. In all of the tests, a non-sorbing tracer (Uranine) and one or two sorbing tracers (cesium and rubidium) have been used simultaneously. A general result is that all of the tests demonstrate a very clear and relatively large retardation effect for the sorbing tracers. Basic initial modelling of the SWIW tests data, using a one-dimensional radial flow model with advection and dispersion, generally resulted in relatively good agreement between model and experimental data. However, a consistent feature of the initial modelling was a discrepancy between model and experimental data in the later parts of the recovery tracer breakthrough curve. It was concluded that this likely was caused by processes occurring in the tested rock formation and therefore an extended model evaluation (presented in this report) including matrix diffusion was carried out on all of the performed tests. Evaluated retardation

  5. Comparison of test performance profile for blood tests of liver fibrosis in chronic hepatitis C.

    Science.gov (United States)

    Halfon, Philippe; Bacq, Yannick; De Muret, Anne; Penaranda, Guillaume; Bourliere, Marc; Ouzan, Denis; Tran, Albert; Botta, Danielle; Renou, Christophe; Bréchot, Marie-Claude; Degott, Claude; Paradis, Valérie

    2007-03-01

    We evaluated the test performance profile (TPP) of blood tests of liver fibrosis. Three hundred and fifty-six patients with C chronic hepatitis were included in two centers. Metavir staging of liver specimens by two independent pathologists and the following tests were evaluated: Fibrotest (FT), APRI, FibroMeter (FM), and Hepascore (HS). Metavir stages were: F0: 4%, F1: 55%, F2: 26%, F3: 11%, and F4: 4%. The AUROCs were not significantly different, respectively, FT, FM, APRI, HS: >or=F2: 0.79, 0.78, 0.76, >or=0.76; F3: 0.81, 0.85, 0.81, 0.81; and F4: 0.86, 0.94, 0.92, 0.89. The TPP relies on the paired comparison of blood-test misclassification based on liver specimen, e.g. FT vs FM, respectively: F0+1: 18 vs 28% (p=0.0003), >or=F2: 43 vs 31% (p=0.004). There was no center effect. In those populations, the four blood tests had a similar performance for significant fibrosis (F>or=2), lying in the lower range of published results which is attributable to a low >or=F2 prevalence, and for >or=F3 and F4. However, FM and FT had performance profiles significantly different as a function of fibrosis stages or diagnostic target (fibrosis cut-off). This has to be considered during the interpretation process. Moreover, the performance should be reported with different diagnostic targets.

  6. Shear punch tests performed using a new low compliance test fixture

    International Nuclear Information System (INIS)

    Toloczko, M.B.; Kurtz, R.J.; Hasegawa, A.; Abe, K.

    2002-01-01

    Based on a recent finite element analysis (FEA) study performed on the shear punch test technique, it was suggested that compliance in a test frame and fixturing which is quite acceptable for uniaxial tensile tests, is much too large for shear punch tests. The FEA study suggested that this relatively large compliance was masking both the true yield point and the shape of the load versus displacement trace obtained in shear punch tests. The knowledge gained from the FEA study was used to design a new shear punch test fixture which more directly measures punch tip displacement. The design of this fixture, the traces obtained from this fixture, and the correlation between uniaxial yield stress and shear yield stress obtained using this fixture are presented here. In general, traces obtained from the new fixture contain much less compliance resulting in a trace shape which is more similar in appearance to a corresponding uniaxial tensile trace. Due to the more direct measurement of displacement, it was possible to measure yield stress at an offset shear strain in a manner analogous to yield stress measurement in a uniaxial tensile test. The correlation between shear yield and uniaxial yield was altered by this new yield measurement technique, but the new correlation was not as greatly improved as was suggested would occur from the FEA study

  7. Performance testing of LiDAR exploitation software

    Science.gov (United States)

    Varela-González, M.; González-Jorge, H.; Riveiro, B.; Arias, P.

    2013-04-01

    Mobile LiDAR systems are being used widely in recent years for many applications in the field of geoscience. One of most important limitations of this technology is the large computational requirements involved in data processing. Several software solutions for data processing are available in the market, but users are often unknown about the methodologies to verify their performance accurately. In this work a methodology for LiDAR software performance testing is presented and six different suites are studied: QT Modeler, AutoCAD Civil 3D, Mars 7, Fledermaus, Carlson and TopoDOT (all of them in x64). Results depict as QTModeler, TopoDOT and AutoCAD Civil 3D allow the loading of large datasets, while Fledermaus, Mars7 and Carlson do not achieve these powerful performance. AutoCAD Civil 3D needs large loading time in comparison with the most powerful softwares such as QTModeler and TopoDOT. Carlson suite depicts the poorest results among all the softwares under study, where point clouds larger than 5 million points cannot be loaded and loading time is very large in comparison with the other suites even for the smaller datasets. AutoCAD Civil 3D, Carlson and TopoDOT show more threads than other softwares like QTModeler, Mars7 and Fledermaus.

  8. Hybrid method for consistent model of the Pacific absolute plate motion and a test for inter-hotspot motion since 70Ma

    Science.gov (United States)

    Harada, Y.; Wessel, P.; Sterling, A.; Kroenke, L.

    2002-12-01

    Inter-hotspot motion within the Pacific plate is one of the most controversial issues in recent geophysical studies. However, it is a fact that many geophysical and geological data including ages and positions of seamount chains in the Pacific plate can largely be explained by a simple model of absolute motion derived from assumptions of rigid plates and fixed hotspots. Therefore we take the stand that if a model of plate motion can explain the ages and positions of Pacific hotspot tracks, inter-hotspot motion would not be justified. On the other hand, if any discrepancies between the model and observations are found, the inter-hotspot motion may then be estimated from these discrepancies. To make an accurate model of the absolute motion of the Pacific plate, we combined two different approaches: the polygonal finite rotation method (PFRM) by Harada and Hamano (2000) and the hot-spotting technique developed by Wessel and Kroenke (1997). The PFRM can determine accurate positions of finite rotation poles for the Pacific plate if the present positions of hotspots are known. On the other hand, the hot-spotting technique can predict present positions of hotspots if the absolute plate motion is given. Therefore we can undertake iterative calculations using the two methods. This hybrid method enables us to determine accurate finite rotation poles for the Pacific plate solely from geometry of Hawaii, Louisville and Easter(Crough)-Line hotspot tracks from around 70 Ma to present. Information of ages can be independently assigned to the model after the poles and rotation angles are determined. We did not detect any inter-hotspot motion from the geometry of these Pacific hotspot tracks using this method. The Ar-Ar ages of Pacific seamounts including new age data of ODP Leg 197 are used to test the newly determined model of the Pacific plate motion. The ages of Hawaii, Louisville, Easter(Crough)-Line, and Cobb hotspot tracks are quite consistent with each other from 70 Ma to

  9. The gender difference on the Mental Rotations test is not due to performance factors.

    Science.gov (United States)

    Masters, M S

    1998-05-01

    Men score higher than women on the Mental Rotations test (MRT), and the magnitude of this gender difference is the largest of that on any spatial test. Goldstein, Haldane, and Mitchell (1990) reported finding that the gender difference on the MRT disappears when "performance factors" are controlled--specifically, when subjects are allowed sufficient time to attempt all items on the test or when a scoring procedure that controls for the number of items attempted is used. The present experiment also explored whether eliminating these performance factors results in a disappearance of the gender difference on the test. Male and female college students were allowed a short time period or unlimited time on the MRT. The tests were scored according to three different procedures. The results showed no evidence that the gender difference on the MRT was affected by the scoring method or the time limit. Regardless of the scoring procedure, men scored higher than women, and the magnitude of the gender difference persisted undiminished when subjects completed all items on the test. Thus there was no evidence that performance factors produced the gender difference on the MRT. These results are consistent with the results of other investigators who have attempted to replicate Goldstein et al.'s findings.

  10. AIChe equipment testing procedure centrifugal compressors : a guide to performance evaluation and site testing

    CERN Document Server

    AIChE

    2013-01-01

    With its engineer-tested procedures and thorough explanations, Centrifugal Compressors is an essential text for anyone engaged in implementing new technology in equipment design, identifying process problems, and optimizing equipment performance.  This condensed book presents a step by step approach to preparing for, planning, executing, and analyzing tests of centrifugal compressors, with an emphasis on methods that can be conducted on-site and with an acknowledgement of the strengths and limitations of these methods. The book opens with an extensive and detailed section offering definitions

  11. Performance test of a portable TLD system for accidental doses

    International Nuclear Information System (INIS)

    Mihelic, M.; Stuhec, M.; Mitic, D.; Vekic, B.; Miljanic, S.; Ban, R.

    2005-01-01

    Full text: A portable TLD measuring system was constructed at the J. Stefan Institute many years ago, motivated by the thread of a catastrophic nuclear event. It was designed for fast measurements in accidental dosimetry mainly for military and civil protection use. The system consists of a robust portable measuring unit built for measurements in field conditions, sized about 40 cm in diameter and weighting 5 kg. Dosimeters are based on CaF 2 :Mn ceramic tablets closed in water resistant plastic housings. In original design producer assured measuring range from cGy to kGy. Specially designed energy compensating filters are used to satisfy requirements for energy response from 0,1 to 3 MeV. Stability of readings is maintained with the temperature stabilized light source. Measuring time for manually driven heating-reading cycle of one dosimeter is about 30 sec. Many systems of the type with sets of dosimeters were stored unused for some years in depositories of different institutions. Modernization of equipment in last years raised questions of applicability of such measurement systems for contemporary needs. The system was thus tested in a secondary standards dosimetry laboratory for compliance with up to date requirements for accidental individual monitoring. Dosimeter characteristics as repeatability, linearity and directional response were of particular interest. As a result of the tests, technical improvements are suggested to extent systems measuring capabilities in order to meet new standards. Possibilities of its use in different fields of dosimetry are discussed, where quick in field measurements of high doses is required as for example in medicine or in civil protection motivated by the new threads of terrorist attacks. (author)

  12. Theoretical and testing performance of an innovative indirect evaporative chiller

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yi; Xie, Xiaoyun [Department of Building Science and Technology, Tsinghua University, Beijing (China)

    2010-12-15

    An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirect evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller

  13. Forward lunge as a functional performance test in ACL deficient subjects: test-retest reliability

    DEFF Research Database (Denmark)

    Alkjaer, Tine; Henriksen, Marius; Dyhre-Poulsen, Poul

    2009-01-01

    The forward lunge movement may be used as a functional performance test of anterior cruciate ligament (ACL) deficient and reconstructed subjects. The purposes were 1) to determine the test-retest reliability of a forward lunge in healthy subjects and 2) to determine the required numbers...... of repetitions necessary to yield satisfactory reliability. Nineteen healthy subjects performed four trials of a forward lunge on two different days. The movement time, impulses of the ground reaction forces (IFz, IFy), knee joint kinematics and dynamics during the forward lunge were calculated. The relative...... reliability was determined by calculation of Intraclass Correlation Coefficients (ICC). The IFz, IFy and the positive work of the knee extensors showed excellent reliability (ICC >0.75). All other variables demonstrated acceptable reliability (0.4>ICCreliability increased when more than...

  14. Testing and Performance Verification of a High Bypass Ratio Turbofan Rotor in an Internal Flow Component Test Facility

    Science.gov (United States)

    VanZante, Dale E.; Podboy, Gary G.; Miller, Christopher J.; Thorp, Scott A.

    2009-01-01

    A 1/5 scale model rotor representative of a current technology, high bypass ratio, turbofan engine was installed and tested in the W8 single-stage, high-speed, compressor test facility at NASA Glenn Research Center (GRC). The same fan rotor was tested previously in the GRC 9x15 Low Speed Wind Tunnel as a fan module consisting of the rotor and outlet guide vanes mounted in a flight-like nacelle. The W8 test verified that the aerodynamic performance and detailed flow field of the rotor as installed in W8 were representative of the wind tunnel fan module installation. Modifications to W8 were necessary to ensure that this internal flow facility would have a flow field at the test package that is representative of flow conditions in the wind tunnel installation. Inlet flow conditioning was designed and installed in W8 to lower the fan face turbulence intensity to less than 1.0 percent in order to better match the wind tunnel operating environment. Also, inlet bleed was added to thin the casing boundary layer to be more representative of a flight nacelle boundary layer. On the 100 percent speed operating line the fan pressure rise and mass flow rate agreed with the wind tunnel data to within 1 percent. Detailed hot film surveys of the inlet flow, inlet boundary layer and fan exit flow were compared to results from the wind tunnel. The effect of inlet casing boundary layer thickness on fan performance was quantified. Challenges and lessons learned from testing this high flow, low static pressure rise fan in an internal flow facility are discussed.

  15. Sealing performance test for main flange of pressure vessel of T2 test section in HENDEL

    International Nuclear Information System (INIS)

    Ioka, Ikuo; Inagaki, Yoshiyuki; Matsumoto, Kiminori; Kondou, Yasuo; Suzuki, Kunihiko; Miyamoto, Yoshiaki; Asami, Masanobu.

    1990-12-01

    A pressure vessel of T 2 test section in helium engineering demonstration loop (HENDEL) was fabricated to the same scale of the reactor pressure vessel made of 2(1/4)Cr-1Mo steel in high temperature engineering test reactor (HTTR). Also, the sealing structure of a main flange of pressure vessel in T 2 test section was composed of the double metal O-rings and Ω-seal which would be used in the sealing structure of HTTR. The sealing performance test for the main flange of the pressure vessel in T 2 test section was carried out to confirm the integrity of sealing structure of a main flange in HTTR. T 2 test section has been operated about 7700 hours in previous 18 cycles. The leakage of helium gas from inner metal O-ring was measured by the static pressurized process under the operating condition of HTTR (helium gas: 400degC, 40kg/cm 2 G, 4gk/s). The calculated leakage of helium gas was less than 9.6x10 -7 atm·cm 3 /sec. From the result, it is expected that the sealing structure of main flange in HTTR would maintain the leak tightness in the life. (author)

  16. Smell test predicts performance on delayed recall memory test in elderly with depression.

    Science.gov (United States)

    Scalco, Monica Z; Streiner, David L; Rewilak, Dmytro; Castel, Saulo; Van Reekum, Robert

    2009-04-01

    Elderly with depression are at increased risk for cognitive dysfunction and dementia. Smell tests are correlated with performance on cognitive tests in the elderly and therefore might serve as a screening test for cognitive impairment in depressed elderly. To assess the validity of the CC-SIT (Cross-Cultural Smell Identification Test) as a screening test for cognitive impairment in elderly with depression. Forty-one patients, aged 60 and over, were assessed with the CC-SIT and CVLT (California Verbal Learning Test) after 3 months treatment of a Major Depressive Episode (DSM-IV) at the Day Hospital for Depression, Baycrest. Patients already diagnosed with dementia, or other psychiatric and neurological disorders, were excluded. Receiver Operating Characteristics (ROC) analysis was applied to assess the CC-SIT's accuracy in identifying individuals with impairment (2 SD below the mean for age and education or less) on CVLT delayed recall trials. Forty-one patients (33 women and eight men) were assessed. Mean age was 76.8 (SD: 6.5), mean HRSD scores before treatment was 22.0 (SD: 5.1). Nine patients had impairment on CVLT delayed recall measures. The area under the ROC curve was 0.776 (95% CI = 0.617-0.936). Our results support the use of the CC-SIT as a screening tool for cognitive impairment among elderly with depression as an indicator for the need of a comprehensive neuropsychological evaluation. Replication with larger samples is necessary. (c) 2008 John Wiley & Sons, Ltd.

  17. Biodiesel production through hydrodynamic cavitation and performance testing

    Energy Technology Data Exchange (ETDEWEB)

    Pal, Amit; Verma, Ashish; Kachhwaha, S.S.; Maji, S. [Department of Mechanical Engineering, Delhi College of Engineering, Bawana Road, Delhi 110042 (India)

    2010-03-15

    This paper presents the details of development of a biodiesel production test rig based on hydrodynamic cavitation followed by results of experimental investigation carried out on a four cylinder, direct injection water cooled diesel engine operating on diesel and biodiesel blend of Citrullus colocyntis (Thumba) oil. The experiment covers a wide range of engine rpm. Results show that biodiesel of Thumba oil produced through hydrodynamic cavitation technique can be used as an alternative fuel with better performance and lower emissions compared to diesel. The most significant conclusions are that (1) Biodiesel production through hydrodynamic cavitation technique seems to be a simple, efficient, time saving, eco-friendly and industrially viable process. (2) 30% biodiesel blend of Thumba oil shows relatively higher brake power, brake thermal efficiency, reduced bsfc and smoke opacity with favourable p-{theta} diagram as compared to diesel. (author)

  18. Confirmation test on confinement performance of improved glove box

    International Nuclear Information System (INIS)

    Miura, S.; Kanazawa, J.; Nakajima, M.; Sakuno, K.; Miyata, H.

    1995-01-01

    Glove boxes are used at nuclear facilities to confine radioactive materials by ensuring a high level of airtightness and negative internal pressure. The allowable rate of air leakage is 0.1% vol/hr or less at the pre-service inspection. The negative pressure value is normally maintained at about -30 mm H 2 O. Structural strength and confinement reliability of glove boxes during earthquake are major concerns, and most important glove boxes are designed to withstand seismic class A events is Japan. This paper describes vibration tests done to confirm that improve large-sized glove boxes maintain their confinement performance and structural strength even during earthquake and that the design analysis methods used are appropriate. (author). 1 ref., 6 figs., 3 tabs

  19. Development and performance test of a solar tracker

    Energy Technology Data Exchange (ETDEWEB)

    Mahdi, T.H.; Hasib, Z.M. [Bangladesh Univ. of Engineering and Technology, Dhaka (Bangladesh). Dept. of Mechanical Engineering

    2010-07-01

    This paper discussed the development of a low-cost solar tracker device designed for use in developing countries. Expert control sensors and input-output interfaces were integrated with a tracking mechanism to increase the energy generation efficiency of the solar panel. Light sensing devices were used to automatically track the sun's rays. The controller sensors were integrated with the tracking mechanism. The control system was implemented on a microcontroller-based embedded system. A graphical user interface (GUI) was incorporated with a commercial software program in order to make the system more user-friendly. Performance tests demonstrated that the tracking system increases the amount of power that the solar panels could obtain. The efficiency of the panels increased by between 18 and 23 percent. Operators were able to control the movement of individual solar panels from a control room. The system also alerted operators of environmental damage to the panels. 12 refs., 2 tabs., 13 figs.

  20. Absolute Navigation Performance of the Orion Exploration Fight Test 1

    Science.gov (United States)

    Zanetti, Renato; Holt, Greg; Gay, Robert; D'Souza, Christopher; Sud, Jastesh

    2016-01-01

    Launched in December 2014 atop a Delta IV Heavy from the Kennedy Space Center, the Orion vehicle's Exploration Flight Test-1 (EFT-1) successfully completed the objective to stress the system by placing the un-crewed vehicle on a high-energy parabolic trajectory replicating conditions similar to those that would be experienced when returning from an asteroid or a lunar mission. Unique challenges associated with designing the navigation system for EFT-1 are presented with an emphasis on how redundancy and robustness influenced the architecture. Two Inertial Measurement Units (IMUs), one GPS receiver and three barometric altimeters (BALTs) comprise the navigation sensor suite. The sensor data is multiplexed using conventional integration techniques and the state estimate is refined by the GPS pseudorange and deltarange measurements in an Extended Kalman Filter (EKF) that employs UDU factorization. The performance of the navigation system during flight is presented to substantiate the design.

  1. Influence of negative stereotypes and beliefs on neuropsychological test performance in a traumatic brain injury population.

    Science.gov (United States)

    Kit, Karen A; Mateer, Catherine A; Tuokko, Holly A; Spencer-Rodgers, Julie

    2014-02-01

    The impact of stereotype threat and self-efficacy beliefs on neuropsychological test performance in a clinical traumatic brain injury (TBI) population was investigated. A total of 42 individuals with mild-to-moderate TBI and 42 (age-, gender-, educationally matched) healthy adults were recruited. The study consisted of a 2 (Type of injury: control, TBI) × 2 (Threat Condition: reduced threat, heightened threat) between-participants design. The purpose of the reduced threat condition was to reduce negative stereotyped beliefs regarding cognitive effects of TBI and to emphasize personal control over cognition. The heightened threat condition consisted of an opposing view. Main effects included greater anxiety, motivation, and dejection but reduced memory self-efficacy for head-injured-groups, compared to control groups. On neuropsychological testing, the TBI-heightened-threat-group displayed lower scores on Initial Encoding (initial recall) and trended toward displaying lower scores on Attention (working memory) compared to the TBI-reduced-threat-group. No effect was found for Delayed Recall measures. Memory self-efficacy mediated the relation between threat condition and neuropsychological performance, indicating a potential mechanism for the threat effect. The findings highlight the impact of stereotype threat and self-referent beliefs on neuropsychological test performance in a clinical TBI population.

  2. Performance Evaluation and Robustness Testing of Advanced Oscilloscope Triggering Schemes

    Directory of Open Access Journals (Sweden)

    Shakeb A. KHAN

    2010-01-01

    Full Text Available In this paper, performance and robustness of two advanced oscilloscope triggering schemes is evaluated. The problem of time period measurement of complex waveforms can be solved using the algorithms, which utilize the associative memory network based weighted hamming distance (Whd and autocorrelation based techniques. Robustness of both the advanced techniques, are then evaluated by simulated addition of random noise of different levels to complex test signals waveforms, and minimum value of Whd (Whd min and peak value of coefficient of correlation(COCmax are computed over 10000 cycles of the selected test waveforms. The distance between mean value of second lowest value of Whd and Whd min and distance between second highest value of coefficient of correlation (COC and COC max are used as parameters to analyze the robustness of considered techniques. From the results, it is found that both the techniques are capable of producing trigger pulses efficiently; but correlation based technique is found to be better from robustness point of view.

  3. metrological performance improvement of a superconducting cable test station

    CERN Document Server

    Montenero, Giuseppe; Ballarino, Amalia

    The work presented in this PhD thesis concerns the metrological performance improvement of a superconducting cable test station based on superconducting transformers. The main cable’s parameter to be assessed –as a function of temperature and magnetic field– is the critical current, i.e. beyond this limit the phase transition to the normal state occurs. Ramping the current at levels in the order of the tens of kA can be achieved with superconducting transformers at moderate capital and operational cost. But, issues such as (i) accurate/precise measurements and (ii) monitoring of the secondary current during the device operation have to be addressed. In this regard, the goals of the thesis are the design, prototyping, and validation of a new cryogenic current transducer and effective monitoring system for test stations transformer-based. Among the available transducers for current sensing at room temperature, the DC current transformer (DCCT) provides measurement accuracy in the order of the hundreds of ...

  4. High School Students' Performance on Vandenberg's Mental Rotations Test: Art Ability, Gender, Activities, Academic Performance, Strategies, and Ease of Taking the Test.

    Science.gov (United States)

    Gurny, Helen Graham

    This study tested whether mental rotation performance of 186 high school students (80 males and 106 females) in grades 9 through 12 in art and nonart classes on Vandenbergs Mental Rotations test (S. Vandenberg and Kuse, 1978) was affected by gender, visual-spatial activities, strategies used while performing the test, and the ease of test taking.…

  5. Proving test on the performance of a Multiple-Excitation Simulator

    International Nuclear Information System (INIS)

    Fujita, Katsuhisa; Ito, Tomohiro; Kojima, Nobuyuki; Sasaki, Yoichi; Abe, Hiroshi; Kuroda, Katsuhiko

    1995-01-01

    Seismic excitation test on large scale piping systems is scheduled to be carried out by the Nuclear power Engineering Corporation (NUPEC) using the large-scale, high-performance vibration table at the Tadotsu Engineering Laboratory, under the sponsorship of the Ministry of International Trade and Industry (MITI). In the test, the piping systems simulate the main steam piping system and the main feed water piping system in the nuclear power plants. In this study, a fundamental test was carried out to prove the performance of the Multiple Excitation Simulator which consists of the hydraulic actuator and the control system. An L-shaped piping system and a hydraulic actuator were installed on the shaking table. Acceleration and displacement generated by the actuator were measured. The performance of the actuator and the control system was discussed comparing the measured values and the target values on the time histories and the response spectrum of the acceleration. As a result, it was proved that the actuator and the control system have good performance and will be applicable to the verification test

  6. The performance-perceptual test and its relationship to unaided reported handicap.

    Science.gov (United States)

    Saunders, Gabrielle H; Forsline, Anna; Fausti, Stephen A

    2004-04-01

    Measurement of hearing aid outcomes is necessary for demonstration of treatment efficacy, third-party payment, and cost-benefit analysis. Outcomes are usually measured with hearing-related questionnaires and/or tests of speech recognition. However, results from these two types of test often conflict. In this paper, we provide data from a new test measure, known as the Performance-Perceptual Test (PPT), in which subjective and performance aspects of hearing in noise are measured using the same test materials and procedures. A Performance Speech Reception Threshold (SRTN) and a Perceptual SRTN are measured using the Hearing In Noise Test materials and adaptive procedure. A third variable, the discrepancy between these two SRTNs, is also computed. It measures the accuracy with which subjects assess their own hearing ability and is referred to as the Performance-Perceptual Discrepancy (PPDIS). One hundred seven subjects between 24 and 83 yr of age took part. Thirty-three subjects had normal hearing, while the remaining seventy-four had symmetrical sensorineural hearing loss. Of the subjects with impaired hearing, 24 wore hearing aids and 50 did not. All subjects underwent routine audiological examination and completed the PPT and the Hearing Handicap Inventory for the Elderly/Adults on two occasions, between 1 and 2 wk apart. The PPT was conducted for unaided listening with the masker level set to 50, 65, and 80 dB SPL. PPT data show that the subjects with normal hearing have significantly better Performance and Perceptual SRTNs at each test level than the subjects with impaired hearing but that PPDIS values do not differ between the groups. Test-retest reliability for the PPT is excellent (r-values > 0.93 for all conditions). Stepwise multiple regression analysis showed that the Performance SRTN, the PPDIS, and age explain 40% of the variance in reported handicap (Hearing Handicap Inventory for the Elderly/Adults scores). More specifically, poorer performance

  7. Fast Flux Test Facility performance monitoring management information

    International Nuclear Information System (INIS)

    Newland, D.J.

    1987-11-01

    The purpose of this report is to provide performance data on key performance indicators selected from the FFTF Early Warning System performance indicators. This report contains the results for key performance indicators divided into two categories of ''overall'' and ''other''. The ''overall'' performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance

  8. How to Perform a Powder in Flexible Die Test

    DEFF Research Database (Denmark)

    Hancock, Mike; Nielsen, Morten Storgaard

    The “Powder in Flexible Die”-test, or PFD-test for short, proposes a new way of testing plastic properties of granular materials. The principal idea for the test originates from Dr. J.I Bech. The test has since been developed further and refined at IPL-DTU. The present work describes the equipment...

  9. Consistent thermodynamic properties of lipids systems

    DEFF Research Database (Denmark)

    Cunico, Larissa; Ceriani, Roberta; Sarup, Bent

    different pressures, with azeotrope behavior observed. Available thermodynamic consistency tests for TPx data were applied before performing parameter regressions for Wilson, NRTL, UNIQUAC and original UNIFAC models. The relevance of enlarging experimental databank of lipids systems data in order to improve......Physical and thermodynamic properties of pure components and their mixtures are the basic requirement for process design, simulation, and optimization. In the case of lipids, our previous works[1-3] have indicated a lack of experimental data for pure components and also for their mixtures...... the performance of predictive thermodynamic models was confirmed in this work by analyzing the calculated values of original UNIFAC model. For solid-liquid equilibrium (SLE) data, new consistency tests have been developed [2]. Some of the developed tests were based in the quality tests proposed for VLE data...

  10. Stress test of the nuclear power plants performed in Taiwan

    Energy Technology Data Exchange (ETDEWEB)

    Wu, C.H.; Teng, W.C.; Chang, S.; Chen, Y.B. [Atomic Energy Council, Taipei, Taiwan (China)

    2014-07-01

    In the wake of Japan's Fukushima Daiichi Nuclear Power Plants event, the Atomic Energy Council (AEC) has asked Taiwan's Nuclear Power Plant operator (TPC) to re-examine and re-evaluate the vulnerabilities of its nuclear units, and furthermore, take possible countermeasures against extreme natural disasters, including earthquake, tsunami and rock-and-mud slide. The evaluation process should be based on both within and beyond Design Basis Accidents, by reference to the actions recommended by the world nuclear authorities and groups, namely, IAEA, USNRC, NEI, ENSREG and WANO. Taiwan is a very densely populated region of the world. Furthermore, like Japan, due to its geophysical position, Taiwan is prone to large scale earthquakes, and although historically rare, Taiwan also faces the potential risk of tsunamis. AEC also asked TPC to perform the stress test following the specification given by WENRA (later ENSREG) and conducted in all the EU's nuclear reactors. After completion of the stress test for all the nuclear power plants, AEC was trying to have the reports peer reviewed by international organizations, as EU did. The OECD/NEA accepted AEC's request and formed a review team specific to the review of Taiwan's National Report for the Stress Test. There were 18 follow-up items after the NEA's review. Based on these items, AEC developed five orders to require TPC further enhancing their capabilities to cope with extreme natural hazards. The ENSREG also formed a nine-expert review team for Taiwan's Stress Test in response to AEC's request almost at the same time as the OECD/NEA. The ENSREG review team began their works in June 2013 by desktop review, and ended in early October 2013 by country visit to Taiwan. While the assessment of post-Fukushima evaluation reveals neither immediate nuclear safety concerns nor threats to the public health and safety, AEC requested that TPC focus on strengthening its re-evaluation on design

  11. Stress test of the nuclear power plants performed in Taiwan

    International Nuclear Information System (INIS)

    Wu, C.H.; Teng, W.C.; Chang, S.; Chen, Y.B.

    2014-01-01

    In the wake of Japan's Fukushima Daiichi Nuclear Power Plants event, the Atomic Energy Council (AEC) has asked Taiwan's Nuclear Power Plant operator (TPC) to re-examine and re-evaluate the vulnerabilities of its nuclear units, and furthermore, take possible countermeasures against extreme natural disasters, including earthquake, tsunami and rock-and-mud slide. The evaluation process should be based on both within and beyond Design Basis Accidents, by reference to the actions recommended by the world nuclear authorities and groups, namely, IAEA, USNRC, NEI, ENSREG and WANO. Taiwan is a very densely populated region of the world. Furthermore, like Japan, due to its geophysical position, Taiwan is prone to large scale earthquakes, and although historically rare, Taiwan also faces the potential risk of tsunamis. AEC also asked TPC to perform the stress test following the specification given by WENRA (later ENSREG) and conducted in all the EU's nuclear reactors. After completion of the stress test for all the nuclear power plants, AEC was trying to have the reports peer reviewed by international organizations, as EU did. The OECD/NEA accepted AEC's request and formed a review team specific to the review of Taiwan's National Report for the Stress Test. There were 18 follow-up items after the NEA's review. Based on these items, AEC developed five orders to require TPC further enhancing their capabilities to cope with extreme natural hazards. The ENSREG also formed a nine-expert review team for Taiwan's Stress Test in response to AEC's request almost at the same time as the OECD/NEA. The ENSREG review team began their works in June 2013 by desktop review, and ended in early October 2013 by country visit to Taiwan. While the assessment of post-Fukushima evaluation reveals neither immediate nuclear safety concerns nor threats to the public health and safety, AEC requested that TPC focus on strengthening its re-evaluation on design

  12. Prognostic durability of liver fibrosis tests and improvement in predictive performance for mortality by combining tests.

    Science.gov (United States)

    Bertrais, Sandrine; Boursier, Jérôme; Ducancelle, Alexandra; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Moal, Valérie; Calès, Paul

    2017-06-01

    There is currently no recommended time interval between noninvasive fibrosis measurements for monitoring chronic liver diseases. We determined how long a single liver fibrosis evaluation may accurately predict mortality, and assessed whether combining tests improves prognostic performance. We included 1559 patients with chronic liver disease and available baseline liver stiffness measurement (LSM) by Fibroscan, aspartate aminotransferase to platelet ratio index (APRI), FIB-4, Hepascore, and FibroMeter V2G . Median follow-up was 2.8 years during which 262 (16.8%) patients died, with 115 liver-related deaths. All fibrosis tests were able to predict mortality, although APRI (and FIB-4 for liver-related mortality) showed lower overall discriminative ability than the other tests (differences in Harrell's C-index: P fibrosis, 1 year in patients with significant fibrosis, and liver disease (MELD) score testing sets. In the training set, blood tests and LSM were independent predictors of all-cause mortality. The best-fit multivariate model included age, sex, LSM, and FibroMeter V2G with C-index = 0.834 (95% confidence interval, 0.803-0.862). The prognostic model for liver-related mortality included the same covariates with C-index = 0.868 (0.831-0.902). In the testing set, the multivariate models had higher prognostic accuracy than FibroMeter V2G or LSM alone for all-cause mortality and FibroMeter V2G alone for liver-related mortality. The prognostic durability of a single baseline fibrosis evaluation depends on the liver fibrosis level. Combining LSM with a blood fibrosis test improves mortality risk assessment. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  13. Development of testing techniques for mine fan performance

    Institute of Scientific and Technical Information of China (English)

    WU Zheng-yan; JIANG Shu-guang; PENG Dan-ren

    2006-01-01

    Three progressive stages of testing techniques are elaborated, which are entirely manual operating, taking separate instruments testing and computer program controlling. The testing method and principle are detailed based on the testing process for meteorological parameters, air pressure, air quality and rotating velocity. And every testing technique is analyzed. Finally, the technique outlook is viewed. All this plays a leading role in development of the testing techniques.

  14. Performance and Test Results of Harshaw Pelletised LiF:Mg,Ti TLD Material

    International Nuclear Information System (INIS)

    Velbeck, K.J.; Zhang, L.; Green, R.; Tomlins, P.

    1999-01-01

    BICRON NE has recently introduced a pelletised version of their popular TLD-100, 600 and 700 lithium fluoride based thermoluminescence dosemeters (TLDs). These materials can be used unmounted or in card and ring formats. Applications include whole-body, environmental, medical, and extremity monitoring. The former manufacturing process included purifying, growing doped LiF, grinding, blending, pressing, slicing, and dicing. The new process eliminates the last four steps, replacing them with a pelletising process. This process transforms the material directly from a powder to its final form. This new process provides the benefits of better batch uniformity and excellent dimensional consistency. The testing is described that was performed for the purpose of accepting the pelletised material as a directly interchangeable substitute for the same material produced by the former process. Tests performed include reproducibility, batch homogeneity, linearity, detection threshold, and light sensitivity. (author)

  15. Design and performance testing of an ultrasonic linear motor with dual piezoelectric actuators.

    Science.gov (United States)

    Smithmaitrie, Pruittikorn; Suybangdum, Panumas; Laoratanakul, Pitak; Muensit, Nantakan

    2012-05-01

    In this work, design and performance testing of an ultrasonic linear motor with dual piezoelectric actuator patches are studied. The motor system consists of a linear stator, a pre-load weight, and two piezoelectric actuator patches. The piezoelectric actuators are bonded with the linear elastic stator at specific locations. The stator generates propagating waves when the piezoelectric actuators are subjected to harmonic excitations. Vibration characteristics of the linear stator are analyzed and compared with finite element and experimental results. The analytical, finite element, and experimental results show agreement. In the experiments, performance of the ultrasonic linear motor is tested. Relationships between velocity and pre-load weight, velocity and applied voltage, driving force and applied voltage, and velocity and driving force are reported. The design of the dual piezoelectric actuators yields a simpler structure with a smaller number of actuators and lower stator stiffness compared with a conventional design of an ultrasonic linear motor with fully laminated piezoelectric actuators.

  16. [Alusti test: New scale for assessment of physical performance in the geriatric population].

    Science.gov (United States)

    Calvo Aguirrey, Juan José; Alustiza Navarro, Josu; Uranga Zaldúa, Joana; Sarasqueta Eizaguirre, Cristina; Bueno Yáñez, Olga

    2018-06-11

    Physical and psychological functional conditions are key factors in the elderly population. Many evaluation tools are available, but they cannot be applied to the whole geriatric population. The use Alusti Test is presented. This test consists of 2versions, which enable it to encompass this wide and complex population spectrum. A prospective study with the institutionalised, hospitalised, and community population, was conducted between September and December 2016. A comparative analysis was conducted using the Barthel Index (BI), Gait Speed Test (GST), Timed «Up & Go» Test (TUG), Short Physical Performance Battery (SPPB), and Tinetti Test. A total of 363 subjects were enrolled (mean age: 83.25 years), with varying levels of functional and cognitive conditions. The test was simple and quick to apply (3-6min), 100% applicable and usable with broad floor and ceiling effects (0-100 points) with an intraclass correlation coefficient (ICC) that shows a high inter-observer reliability (ICC = 0.99), and a good correlation in its full version with BI (ICC = 0.86) (95% CI: 0.82-0.88), and the Tinetti test (ICC = 0.76; 95% CI: 0.71-0.81), as well as in the abbreviated version BI (ICC = 0.71; 95% CI: 0.65-0.75) and Tinetti Test (ICC = 0.90; 95% CI: 0.88-0.92). This allows the variation of the functional condition to be measured, which in our sample showed an increase of 10.9%, after a period of hospital admission. It is considered that Alusti test meets the requirements for physical performance assessment in the whole the geriatric population. The highest level of accuracy is given by the Tinetti test, which has greater applicability. Copyright © 2018 SEGG. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Basic considerations for the preparation of performance testing materials as related to performance evaluation acceptance criteria

    International Nuclear Information System (INIS)

    McCurdy, D.E.; Morton, J.S.

    2001-01-01

    The preparation of performance testing (PT) materials for environmental and radiobioassay applications involves the use of natural matrix materials containing the analyte of interest, the addition (spiking) of the analyte to a desired matrix (followed by blending for certain matrices) or a combination of the two. The distribution of the sample analyte concentration in a batch of PT samples will reflect the degree of heterogeneity of the analyte in the PT material and/or the reproducibility of the sample preparation process. Commercial and government implemented radioanalytical performance evaluation programs have a variety of acceptable performance criteria. The performance criteria should take into consideration many parameters related to the preparation of the PT materials including the within and between sample analyte heterogeneity, the accuracy of the quantification of an analyte in the PT material and to what 'known' value will a laboratory's result be compared. How sample preparation parameters affect the successful participation in performance evaluation (PE) programs having an acceptance criteria established as a percent difference from a 'known' value or in PE programs using other acceptance criteria, such as the guidance provided in ANSI N42.22 and N13.30 is discussed. (author)

  18. Fast Flux Test Facility performance monitoring management information: [Final report

    International Nuclear Information System (INIS)

    Newland, D.J.

    1987-09-01

    The purpose of this report is to provide management with performance data on key performance indicators for the month of July, 1987. This report contains the results for key performance indicators divided into two categories of ''overall'' and ''other''. The ''overall'' performance indicators, when considered in the aggregate, provide one means of monitoring overall plant performance

  19. Bench tests of simple, handy ventilators for pandemics: performance, autonomy, and ergonomy.

    Science.gov (United States)

    L'Her, Erwan; Roy, Annie

    2011-06-01

    It has been pointed out that in the wake of a virulent flu strain, patients with survivable illness will die from lack of resources unless more ventilators are made available. Numerous disaster-type ventilators are available, but few evaluations have been performed. To compare simple, lightweight, and handy ventilators that could be used in the initial care of patients with respiratory distress. We bench-tested 4 volume-cycled ventilators (Carevent ALS, EPV100, Pneupac VR1, and Medumat Easy) and 2 pressure-cycled ventilators (Oxylator EMX and VAR-Plus). We studied their general physical characteristics, sonometry, gas consumption, technical performance, ergonomy, and user-friendliness. With a test lung we assessed performance at F(IO(2)) of 0.50 and 1.0, set compliance of 30, 70, and 120 mL/cm H(2)O, and set resistance of 5, 10, and 20 cm H(2)O/L/s. To study user-friendliness and ergonomy we conducted, in randomized order, 7 or 8 objective, quantitative tests and 2 subjective tests. Compliance and resistance strongly affected tidal volume with the pressure-cycled ventilators (from 418 ± 49 mL to 1,377 ± 444 mL with the VAR-Plus, at the lowest pressure level), whereas the volume-cycled ventilators provided a consistent tidal volume in the face of changing test lung characteristics. We are concerned that the pressure-cycled ventilators did not provide a consistent tidal volume, and under certain conditions the volume delivered would be unsafe (too large or too small). Most of the volume-cycled ventilators proved to be technically efficient and reliable. Their reliability, portability, and ease of use could make them valuable in natural disasters and mass-casualty events.

  20. Variability in performance on a work simulation test of physical fitness for firefighters.

    Science.gov (United States)

    Boyd, Liam; Rogers, Todd; Docherty, David; Petersen, Stewart

    2015-04-01

    The Canadian Forces Firefighter Physical Fitness Maintenance Evaluation (FF PFME) requires firefighters in full fire-protective ensemble, including self-contained breathing apparatus, to correctly complete 10 work-related tasks on a measured and calibrated course. Fitness for duty is inferred from completion time of the course. We hypothesized that completion time may be dependent on pacing strategy and day-to-day fluctuations in biological function. To examine variability in performance, 20 females and 31 males (mean ± SD; age, 27.6 ± 10.5 years; height, 176.7 ± 8.3 cm; mass, 77.3 ± 13.4 kg) were familiarized with the FF PFME and then completed the test on 6 separate days. Pre-test behaviours (e.g., sleep, diet) and test conditions (e.g., calibration, time of day) were consistent. Repeated-measures ANOVA revealed a significant decrease in completion time between tests 1 and 6 (18.7%) and between all sequential pairs (e.g., tests 1 and 2). There was also a small but significant increase in the fraction of total test time for task completion and a corresponding decrease in the time to transition between tasks. The performance improvements cannot be explained by differences in effort (heart rate and perceived exertion). Coefficient of variation for tests 1, 2, and 3 was 7% and for tests 4, 5, and 6 was 2.6%. The results indicate the importance of practice on performance and the potential for false-positive or false-negative decision errors if biological variability is not taken into account.