WorldWideScience

Sample records for performance study volume

  1. Training volume and performance of young Spanish national and ...

    African Journals Online (AJOL)

    The objective of the present study was to determine the volume of training of young national and international level swimmers, how it evolves andits relationship with performance. The sample comprised of 202 swimmers (11to 18 years old), selected by the Royal Spanish Swimming Federation. The volumes of pool and ...

  2. ALICE: Physics Performance Report, Volume II

    International Nuclear Information System (INIS)

    Alessandro, B; Antinori, F; Belikov, J A

    2006-01-01

    ALICE is a general-purpose heavy-ion experiment designed to study the physics of strongly interacting matter and the quark-gluon plasma in nucleus-nucleus collisions at the LHC. It currently involves more than 900 physicists and senior engineers, from both the nuclear and high-energy physics sectors, from over 90 institutions in about 30 countries. The ALICE detector is designed to cope with the highest particle multiplicities above those anticipated for Pb-Pb collisions (dN ch /dy up to 8000) and it will be operational at the start-up of the LHC. In addition to heavy systems, the ALICE Collaboration will study collisions of lower-mass ions, which are a means of varying the energy density, and protons (both pp and pA), which primarily provide reference data for the nucleus-nucleus collisions. In addition, the pp data will allow for a number of genuine pp physics studies. The detailed design of the different detector systems has been laid down in a number of Technical Design Reports issued between mid-1998 and the end of 2004. The experiment is currently under construction and will be ready for data taking with both proton and heavy-ion beams at the start-up of the LHC. Since the comprehensive information on detector and physics performance was last published in the ALICE Technical Proposal in 1996, the detector, as well as simulation, reconstruction and analysis software have undergone significant development. The Physics Performance Report (PPR) provides an updated and comprehensive summary of the performance of the various ALICE subsystems, including updates to the Technical Design Reports, as appropriate. The PPR is divided into two volumes. Volume I, published in 2004 (CERN/LHCC 2003-049, ALICE Collaboration 2004 J. Phys. G: Nucl. Part. Phys. 30 1517-1763), contains in four chapters a short theoretical overview and an extensive reference list concerning the physics topics of interest to ALICE, the experimental conditions at the LHC, a short summary and update

  3. Mars power system concept definition study. Volume 2: Appendices

    Science.gov (United States)

    Littman, Franklin D.

    1994-01-01

    This report documents the work performed by Rockwell International's Rocketdyne Division on NASA Contract No. NAS3-25808 (Task Order No. 16) entitled 'Mars Power System Definition Study'. This work was performed for NASA's Lewis Research Center (LeRC). The report is divided into two volumes as follows: Volume 1 - Study Results; and Volume 2 - Appendices. The results of the power system characterization studies, operations studies, and technology evaluations are summarized in Volume 1. The appendices include complete, standalone technology development plans for each candidate power system that was investigated.

  4. The physics benchmark processes for the detector performance studies used in CLIC CDR Volume 3

    CERN Document Server

    Allanach, B.J.; Desch, K.; Ellis, J.; Giudice, G.; Grefe, C.; Kraml, S.; Lastovicka, T.; Linssen, L.; Marschall, J.; Martin, S.P.; Muennich, A.; Poss, S.; Roloff, P.; Simon, F.; Strube, J.; Thomson, M.; Wells, J.D.

    2012-01-01

    This note describes the detector benchmark processes used in volume 3 of the CLIC conceptual design report (CDR), which explores a staged construction and operation of the CLIC accelerator. The goal of the detector benchmark studies is to assess the performance of the CLIC ILD and CLIC SiD detector concepts for different physics processes and at a few CLIC centre-of-mass energies.

  5. Intake plenum volume and its influence on the engine performance, cyclic variability and emissions

    International Nuclear Information System (INIS)

    Ceviz, M.A.

    2007-01-01

    Intake manifold connects the intake system to the intake valve of the engine and through which air or air-fuel mixture is drawn into the cylinder. Details of the flow in intake manifolds are extremely complex. Recently, most of engine companies are focused on variable intake manifold technology due to their improvement on engine performance. This paper investigates the effects of intake plenum volume variation on engine performance and emissions to constitute a base study for variable intake plenum. Brake and indicated engine performance characteristics, coefficient of variation in indicated mean effective pressure (COV imep ) as an indicator for cyclic variability, pulsating flow pressure in the intake manifold runner, and CO, CO 2 and HC emissions were taken into consideration to evaluate the effects of different plenum volumes. The results of this study showed that the variation in the plenum volume causes an improvement on the engine performance and the pollutant emissions. The brake torque and related performance characteristics improved pronouncedly about between 1700 and 2600 rpm by increasing plenum volume. Additionally, although the increase in the plenum volume caused the mixture leaner due to the increase in the intake runner pressure and lean mixtures inclined to increase the cyclic variability, a decrease was interestingly observed in the COV imep

  6. Effect of radiologists' diagnostic work-up volume on interpretive performance.

    Science.gov (United States)

    Buist, Diana S M; Anderson, Melissa L; Smith, Robert A; Carney, Patricia A; Miglioretti, Diana L; Monsees, Barbara S; Sickles, Edward A; Taplin, Stephen H; Geller, Berta M; Yankaskas, Bonnie C; Onega, Tracy L

    2014-11-01

    To examine radiologists' screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. In an institutional review board-approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [ FPR false-positive rate ], and cancer detection rate [ CDR cancer detection rate ]). Logistic regression was used to assess the association between the volume of recalled screening mammograms ("own" mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and "any" mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0-50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0-50 mammograms, 32% performed the work-up for 51-125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPR false-positive rate (P = .004), and CDR cancer detection rate (P women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant

  7. Effect of Radiologists’ Diagnostic Work-up Volume on Interpretive Performance

    Science.gov (United States)

    Anderson, Melissa L.; Smith, Robert A.; Carney, Patricia A.; Miglioretti, Diana L.; Monsees, Barbara S.; Sickles, Edward A.; Taplin, Stephen H.; Geller, Berta M.; Yankaskas, Bonnie C.; Onega, Tracy L.

    2014-01-01

    Purpose To examine radiologists’ screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists. Materials and Methods In an institutional review board–approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [FPRfalse-positive rate], and cancer detection rate [CDRcancer detection rate]). Logistic regression was used to assess the association between the volume of recalled screening mammograms (“own” mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and “any” mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up. Results Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0–50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0–50 mammograms, 32% performed the work-up for 51–125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPRfalse-positive rate (P = .004), and CDRcancer detection rate (P work-ups for any radiologist yielded significant increases in FPRfalse-positive rate (P = .011) and CDRcancer detection rate (P

  8. Combined effects of marijuana and nicotine on memory performance and hippocampal volume.

    Science.gov (United States)

    Filbey, Francesca M; McQueeny, Tim; Kadamangudi, Shrinath; Bice, Collette; Ketcherside, Ariel

    2015-10-15

    Combined use of marijuana (MJ) and tobacco is highly prevalent in today's population. Individual use of either substance is linked to structural brain changes and altered cognitive function, especially with consistent reports of hippocampal volume deficits and poorer memory performance. However, the combined effects of MJ and tobacco on hippocampal structure and on learning and memory processes remain unknown. In this study, we examined both the individual and combined effects of MJ and tobacco on hippocampal volumes and memory performance in four groups of adults taken from two larger studies: MJ-only users (n=36), nicotine-only (Nic-only, n=19), combined marijuana and nicotine users (MJ+Nic, n=19) and non-using healthy controls (n=16). Total bilateral hippocampal volumes and memory performance (WMS-III logical memory) were compared across groups controlling for total brain size and recent alcohol use. Results found MJ and MJ+Nic groups had smaller total hippocampal volumes compared to Nic-only and controls. No significant difference between groups was found between immediate and delayed story recall. However, the controls showed a trend for larger hippocampal volumes being associated with better memory scores, while MJ+Nic users showed a unique inversion, whereby smaller hippocampal volume was associated with better memory. Overall, results suggest abnormalities in the brain-behavior relationships underlying memory processes with combined use of marijuana and nicotine use. Further research will need to address these complex interactions between MJ and nicotine. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  9. Bigger is better! Hippocampal volume and declarative memory performance in healthy young men.

    Science.gov (United States)

    Pohlack, Sebastian T; Meyer, Patric; Cacciaglia, Raffaele; Liebscher, Claudia; Ridder, Stephanie; Flor, Herta

    2014-01-01

    The importance of the hippocampus for declarative memory processes is firmly established. Nevertheless, the issue of a correlation between declarative memory performance and hippocampal volume in healthy subjects still remains controversial. The aim of the present study was to investigate this relationship in more detail. For this purpose, 50 healthy young male participants performed the California Verbal Learning Test. Hippocampal volume was assessed by manual segmentation of high-resolution 3D magnetic resonance images. We found a significant positive correlation between putatively hippocampus-dependent memory measures like short-delay retention, long-delay retention and discriminability and percent hippocampal volume. No significant correlation with measures related to executive processes was found. In addition, percent amygdala volume was not related to any of these measures. Our data advance previous findings reported in studies of brain-damaged individuals in a large and homogeneous young healthy sample and are important for theories on the neural basis of episodic memory.

  10. Blood volume studies

    International Nuclear Information System (INIS)

    Lewis, S.M.; Yin, J.A.L.

    1986-01-01

    The use of dilution analysis with such radioisotopes as 51 Cr, 32 P, sup(99m)Tc and sup(113m)In for measuring red cell volume is reviewed briefly. The use of 125 I and 131 I for plasma volume studies is also considered and the subsequent determination of total blood volume discussed, together with the role of the splenic red cell volume. Substantial bibliography. (UK)

  11. Mean platelet volume (MPV) predicts middle distance running performance.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Danese, Elisa; Skafidas, Spyros; Tarperi, Cantor; Guidi, Gian Cesare; Schena, Federico

    2014-01-01

    Running economy and performance in middle distance running depend on several physiological factors, which include anthropometric variables, functional characteristics, training volume and intensity. Since little information is available about hematological predictors of middle distance running time, we investigated whether some hematological parameters may be associated with middle distance running performance in a large sample of recreational runners. The study population consisted in 43 amateur runners (15 females, 28 males; median age 47 years), who successfully concluded a 21.1 km half-marathon at 75-85% of their maximal aerobic power (VO2max). Whole blood was collected 10 min before the run started and immediately thereafter, and hematological testing was completed within 2 hours after sample collection. The values of lymphocytes and eosinophils exhibited a significant decrease compared to pre-run values, whereas those of mean corpuscular volume (MCV), platelets, mean platelet volume (MPV), white blood cells (WBCs), neutrophils and monocytes were significantly increased after the run. In univariate analysis, significant associations with running time were found for pre-run values of hematocrit, hemoglobin, mean corpuscular hemoglobin (MCH), red blood cell distribution width (RDW), MPV, reticulocyte hemoglobin concentration (RetCHR), and post-run values of MCH, RDW, MPV, monocytes and RetCHR. In multivariate analysis, in which running time was entered as dependent variable whereas age, sex, blood lactate, body mass index, VO2max, mean training regimen and the hematological parameters significantly associated with running performance in univariate analysis were entered as independent variables, only MPV values before and after the trial remained significantly associated with running time. After adjustment for platelet count, the MPV value before the run (p = 0.042), but not thereafter (p = 0.247), remained significantly associated with running

  12. Mean platelet volume (MPV predicts middle distance running performance.

    Directory of Open Access Journals (Sweden)

    Giuseppe Lippi

    Full Text Available Running economy and performance in middle distance running depend on several physiological factors, which include anthropometric variables, functional characteristics, training volume and intensity. Since little information is available about hematological predictors of middle distance running time, we investigated whether some hematological parameters may be associated with middle distance running performance in a large sample of recreational runners.The study population consisted in 43 amateur runners (15 females, 28 males; median age 47 years, who successfully concluded a 21.1 km half-marathon at 75-85% of their maximal aerobic power (VO2max. Whole blood was collected 10 min before the run started and immediately thereafter, and hematological testing was completed within 2 hours after sample collection.The values of lymphocytes and eosinophils exhibited a significant decrease compared to pre-run values, whereas those of mean corpuscular volume (MCV, platelets, mean platelet volume (MPV, white blood cells (WBCs, neutrophils and monocytes were significantly increased after the run. In univariate analysis, significant associations with running time were found for pre-run values of hematocrit, hemoglobin, mean corpuscular hemoglobin (MCH, red blood cell distribution width (RDW, MPV, reticulocyte hemoglobin concentration (RetCHR, and post-run values of MCH, RDW, MPV, monocytes and RetCHR. In multivariate analysis, in which running time was entered as dependent variable whereas age, sex, blood lactate, body mass index, VO2max, mean training regimen and the hematological parameters significantly associated with running performance in univariate analysis were entered as independent variables, only MPV values before and after the trial remained significantly associated with running time. After adjustment for platelet count, the MPV value before the run (p = 0.042, but not thereafter (p = 0.247, remained significantly associated with running

  13. Effects of horizontal plyometric training volume on soccer players' performance.

    Science.gov (United States)

    Yanci, Javier; Los Arcos, Asier; Camara, Jesús; Castillo, Daniel; García, Alberto; Castagna, Carlo

    2016-01-01

    The aim of this study was to examine the dose response effect of strength and conditioning programmes, involving horizontally oriented plyometric exercises, on relevant soccer performance variables. Sixteen soccer players were randomly allocated to two 6-week plyometric training groups (G1 and G2) differing by imposed (twice a week) training volume. Post-training G1 (4.13%; d = 0.43) and G2 (2.45%; d = 0.53) moderately improved their horizontal countermovement jump performance. Significant between-group differences (p  0.05, d = trivial or small) post-training improvements in sprint, change of direction ability (CODA) and horizontal arm swing countermovement jump were reported in either group. Horizontal plyometric training was effective in promoting improvement in injury prevention variables. Doubling the volume of a horizontal plyometric training protocol was shown to have no additional effect over functional aspects of soccer players' performance.

  14. Surgical volume and conversion rate in laparoscopic hysterectomy: does volume matter? A multicenter retrospective cohort study.

    Science.gov (United States)

    Keurentjes, José H M; Briët, Justine M; de Bock, Geertruida H; Mourits, Marian J E

    2018-02-01

    A multicenter, retrospective, cohort study was conducted in the Netherlands. The aim was to evaluate whether surgical volume of laparoscopic hysterectomies (LHs) performed by proven skilled gynecologists had an impact on the conversion rate from laparoscopy to laparotomy. In 14 hospitals, all LHs performed by 19 proven skilled gynecologists between 2007 and 2010 were included in the analysis. Surgical volume, conversion rate and type of conversion (reactive or strategic) were retrospectively assessed. To estimate the impact of surgical volume on the conversion rate, logistic regressions were performed. These regressions were adjusted for patient's age, Body Mass Index (BMI), ASA classification, previous abdominal surgery and the indication (malignant versus benign) for the LH. During the study period, 19 proven skilled gynecologists performed a total of 1051 LHs. Forty percent of the gynecologists performed over 20 LHs per year (median 17.3, range 5.4-49.5). Conversion to laparotomy occurred in 5.0% of all LHs (53 of 1051); 38 (3.6%) were strategic and 15 (1.4%) were reactive conversions. Performing over 20 LHs per year was significantly associated with a lower overall conversion rate (OR adjusted 0.43, 95% CI 0.24-0.77), a lower strategic conversion rate (OR adjusted 0.32, 95% CI 0.16-0.65), but not with a lower reactive conversion rate (OR adjusted 0.96, 95% CI 0.33-2.79). A higher annual surgical volume of LHs by proven skilled gynecologists is inversely related to the conversion rate to laparotomy, and results in a lower strategic conversion rate.

  15. Calibration of automatic performance measures - speed and volume data: volume 2, evaluation of the accuracy of approach volume counts and speeds collected by microwave sensors.

    Science.gov (United States)

    2016-05-01

    This study evaluated the accuracy of approach volumes and free flow approach speeds collected by the Wavetronix : SmartSensor Advance sensor for the Signal Performance Metrics system of the Utah Department of Transportation (UDOT), : using the field ...

  16. Comparison of the outcomes for laparoscopic gastrectomy performed by the same surgeon between a low-volume hospital and a high-volume center.

    Science.gov (United States)

    Kim, Min Gyu; Kwon, Sung Joon

    2014-05-01

    The volume-outcome relationship in laparoscopic surgery is controversial. This study was designed to identify differences in laparoscopic gastrectomy outcomes between a low-volume hospital and a high-volume center and to provide guidelines for overcoming the problems associated with a low-volume hospital. From April 2009 to November 2012, one surgeon performed 134 totally laparoscopic distal gastrectomies (TLDGs) at a high-volume center (HVC; ASAN Medical Center) and at a low-volume hospital (LVH; Hanyang University Guri Hospital). All laparoscopically assisted gastrectomies were excluded from this study. During the early period of laparoscopic gastrectomy at the low-volume hospital, TLDG with Roux-en-Y gastrojejunostomy (RYGJ) was performed according to the surgeon's choice. The reconstruction method was classified as gastroduodenostomy (GD) or RYGJ. Early surgical outcomes achieved at the LVH were investigated and compared with those obtained at the HVC. The early surgical outcomes differed significantly between the two hospitals. In particular, the postoperative complication rate for the patients who underwent TLDG RYGJ at the LVH was higher than at the HVC (LVH 15.4 % vs. HVC 0 %; p = 0.037). Furthermore, significant differences were observed in the mean operation time (TLDG GD: LVH 141.0 min vs. HVC 117.4 min, p = 0.001; TLDG RYGJ: LVH 186.3 min vs. HVC 134.6 min, p = 0.009) and length of hospital stay (TLDG GD: LVH 8.1 days vs. HVC 7.2 days, p = 0.044; TLDG RYGJ: LVH 11.5 day vs. HVC 6.8 day, p = 0.009). Although all the operations were performed by one experienced surgeon, the early surgical outcomes differed significantly between the low- and high-volume hospitals. Low-volume hospitals often lack well-trained surgical professionals such as first assistants and scrub nurses. Therefore, the authors recommend that a surgeon who works at an LVH should assess potential personnel shortages and find a solution before operating.

  17. Functionality and Performance Visualization of the Distributed High Quality Volume Renderer (HVR)

    KAUST Repository

    Shaheen, Sara

    2012-07-01

    Volume rendering systems are designed to provide means to enable scientists and a variety of experts to interactively explore volume data through 3D views of the volume. However, volume rendering techniques are computationally intensive tasks. Moreover, parallel distributed volume rendering systems and multi-threading architectures were suggested as natural solutions to provide an acceptable volume rendering performance for very large volume data sizes, such as Electron Microscopy data (EM). This in turn adds another level of complexity when developing and manipulating volume rendering systems. Given that distributed parallel volume rendering systems are among the most complex systems to develop, trace and debug, it is obvious that traditional debugging tools do not provide enough support. As a consequence, there is a great demand to provide tools that are able to facilitate the manipulation of such systems. This can be achieved by utilizing the power of compute graphics in designing visual representations that reflect how the system works and that visualize the current performance state of the system.The work presented is categorized within the field of software Visualization, where Visualization is used to serve visualizing and understanding various software. In this thesis, a number of visual representations that reflect a number of functionality and performance aspects of the distributed HVR, a high quality volume renderer system that uses various techniques to visualize large volume sizes interactively. This work is provided to visualize different stages of the parallel volume rendering pipeline of HVR. This is along with means of performance analysis through a number of flexible and dynamic visualizations that reflect the current state of the system and enables manipulation of them at runtime. Those visualization are aimed to facilitate debugging, understanding and analyzing the distributed HVR.

  18. Volume Morto: performance e corporeidade

    Directory of Open Access Journals (Sweden)

    Eloísa Brantes Mendes

    Full Text Available Resumo O processo de pesquisa e criação do espetáculo Volume Morto é o campo de partida deste relato sobre performance, memória corporal e relações estético-políticas implicadas na trajetória artística do Coletivo Líquida Ação desde 2007. A presença da água como elemento vital, utilizada nas performances de intervenção urbana, faz parte da proposta artística deste coletivo que problematiza as fronteiras entre visibilidades e invisibilidades da cidade habitada. A água, ligada às múltiplas temporalidades da experiência corpo-espaço na ação performática, também vai ao encontro das práticas de convívio e produção artística, voltadas para a sustentabilidade do próprio coletivo como espaço de pesquisa independente.

  19. Powder metallurgical high performance materials. Proceedings. Volume 4: late papers

    Energy Technology Data Exchange (ETDEWEB)

    Kneringer, G; Roedhammer, P; Wildner, H [eds.

    2001-07-01

    This is the fourth volume (late papers) of the 15th International Plansee seminar 2001 which general theme was 'Powder metallurgical high performance materials'. The seminar looked beyond the refractory metals and cemented carbides, which remain as its focus, to novel classes of materials, such as intermetallic compounds, with potential for high temperature applications. This volume 4 contains papers dealing with high performance P/M metals (ITER and fusion reactors, solid targets, materials microstructure, novel alloys, etc.), P/M hard materials ( production and characterization, tungsten carbides, titanium carbides, microstructural design, coatings composition and performance, etc.) and general topics. From 37 papers 24 correspond to INIS subject scope and they were indexed separately. (nevyjel)

  20. Powder metallurgical high performance materials. Proceedings. Volume 4: late papers

    International Nuclear Information System (INIS)

    Kneringer, G.; Roedhammer, P.; Wildner, H.

    2001-01-01

    This is the fourth volume (late papers) of the 15th International Plansee seminar 2001 which general theme was 'Powder metallurgical high performance materials'. The seminar looked beyond the refractory metals and cemented carbides, which remain as its focus, to novel classes of materials, such as intermetallic compounds, with potential for high temperature applications. This volume 4 contains papers dealing with high performance P/M metals (ITER and fusion reactors, solid targets, materials microstructure, novel alloys, etc.), P/M hard materials ( production and characterization, tungsten carbides, titanium carbides, microstructural design, coatings composition and performance, etc.) and general topics. From 37 papers 24 correspond to INIS subject scope and they were indexed separately. (nevyjel)

  1. Controlled air incinerator for radioactive waste. Volume I. Rationale, process, equipment, performance, and recommendations

    International Nuclear Information System (INIS)

    Neuls, A.S.; Draper, W.E.; Koenig, R.A.; Newmyer, J.M.; Warner, C.L.

    1982-11-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawings specifications, calculations, and costs. It aids duplication of the process at other facilities

  2. Production performance laws of vertical wells by volume fracturing in CBM reservoirs

    Directory of Open Access Journals (Sweden)

    Liehui Zhang

    2017-05-01

    Full Text Available Volume fracturing technology has been widely applied in the development of coalbed methane (CBM reservoirs. As for the stimulated reservoir volume (SRV created by volume fracturing, the seepage laws of fluids are described more accurately and rationally in the rectangular composite model than in the traditional radial composite model. However, the rectangular composite model considering SRV cannot be solved using the analytical or semi-analytical function method, and its solution from the linear flow model has larger errors. In view of this, SRV areas of CBM reservoirs were described by means of dual-medium model in this paper. The complex CBM migration mechanisms were investigated comprehensively, including adsorption, desorption, diffusion and seepage. A well testing model for rectangular composite fracturing wells in CBM reservoirs based on unsteady-state diffusion was built and solved using the boundary element method combined with Laplace transformation, Stehfest numerical inversion and computer programming technology. Thus, production performance laws of CBM reservoirs were clarified. The flow regimes of typical well testing curves were divided and the effects on change laws of production performance from the boundary size of gas reservoirs, permeability of volume fractured areas, adsorption gas content, reservoir permeability and SRV size were analyzed. Eventually, CBM reservoirs after the volume fracturing stimulation were described more accurately and rationally. This study provides a theoretical basis for a better understanding of the CBM migration laws and an approach to evaluating and developing CBM reservoirs efficiently and rationally.

  3. Senior Dance Experience, Cognitive Performance, and Brain Volume in Older Women

    Directory of Open Access Journals (Sweden)

    Claudia Niemann

    2016-01-01

    Full Text Available Physical activity is positively related to cognitive functioning and brain volume in older adults. Interestingly, different types of physical activity vary in their effects on cognition and on the brain. For example, dancing has become an interesting topic in aging research, as it is a popular leisure activity among older adults, involving cardiovascular and motor fitness dimensions that can be positively related to cognition. However, studies on brain structure are missing. In this study, we tested the association of long-term senior dance experience with cognitive performance and gray matter brain volume in older women aged 65 to 82 years. We compared nonprofessional senior dancers (n=28 with nonsedentary control group participants without any dancing experience (n=29, who were similar in age, education, IQ score, lifestyle and health factors, and fitness level. Differences neither in the four tested cognitive domains (executive control, perceptual speed, episodic memory, and long-term memory nor in brain volume (VBM whole-brain analysis, region-of-interest analysis of the hippocampus were observed. Results indicate that moderate dancing activity (1-2 times per week, on average has no additional effects on gray matter volume and cognitive functioning when a certain lifestyle or physical activity and fitness level are reached.

  4. The SEMA5A gene is associated with hippocampal volume, and their interaction is associated with performance on Raven's Progressive Matrices.

    Science.gov (United States)

    Zhu, Bi; Chen, Chuansheng; Xue, Gui; Moyzis, Robert K; Dong, Qi; Chen, Chunhui; Li, Jin; He, Qinghua; Lei, Xuemei; Wang, Yunxin; Lin, Chongde

    2014-03-01

    The Allen Brain Atlas shows that the semaphorin 5A (SEMA5A) gene, which encodes an important protein for neurogenesis and neuronal apoptosis, is predominantly expressed in the human hippocampus. Structural and functional neuroimaging studies have further shown that the hippocampus plays an important role in the performance on Raven's Progressive Matrices (RPM), a measure of reasoning ability and general fluid intelligence. Thus far, however, no study has examined the relationships between the SEMA5A gene polymorphism, hippocampal volume, and RPM performance. The current study collected both structural MRI, genetic, and behavioral data in 329 healthy Chinese adults, and examined associations between SEMA5A variants, hippocampal volume, and performance on RAPM (the advanced form of RPM). After controlling for intracranial volume (ICV), sex, and age, SEMA5A genetic polymorphism at the SNP rs42352 had the strongest association with hippocampal volume (p=0.00000552 and 0.000103 for right and left hippocampal volumes, respectively), with TT homozygotes having higher hippocampal volume than the other genotypes. Furthermore, there was a high correlation between right hippocampal volume and RAPM performance (r=0.42, p=0.0000509) for SEMA5A rs42352 TT homozygotes. This study provides the first evidence for the involvement of the SEMA5A gene in hippocampal structure and their interaction on RAPM performance. Future studies of the hippocampus-RPM associations should consider genetic factors as potential moderators. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. High "normal" blood glucose is associated with decreased brain volume and cognitive performance in the 60s: the PATH through life study.

    Directory of Open Access Journals (Sweden)

    Moyra E Mortby

    Full Text Available Type 2 diabetes is associated with cerebral atrophy, cognitive impairment and dementia. We recently showed higher glucose levels in the normal range not to be free of adverse effects and to be associated with greater hippocampal and amygdalar atrophy in older community-dwelling individuals free of diabetes.This study aimed to determine whether blood glucose levels in the normal range (<6.1 mmol/L were associated with cerebral volumes in structures other than the hippocampus and amygdale, and whether these glucose-related regional volumes were associated with cognitive performance.210 cognitively healthy individuals (68-73 years without diabetes, glucose intolerance or metabolic syndrome were assessed in the large, community-based Personality and Total Health Through Life (PATH study.Baseline blood glucose levels in the normal range (3.2-6.1 mmol/l were used to determine regional brain volumes and associated cognitive function at wave 3.Higher blood glucose levels in the normal range were associated with lower grey/white matter regional volumes in the frontal cortices (middle frontal gyrus, inferior frontal gyrus precentral gyrus. Moreover, identified cerebral regions were associated with poorer cognitive performance and the structure-function associations were gender specific to men.These findings stress the need to re-evaluate what is considered as healthy blood glucose levels, and consider the role of higher normal blood glucose as a risk factor for cerebral health, cognitive function and dementia. A better lifetime management of blood glucose levels may contribute to improved cerebral and cognitive health in later life and possibly protect against dementia.

  6. Prehospital tidal volume influences hospital tidal volume: A cohort study.

    Science.gov (United States)

    Stoltze, Andrew J; Wong, Terrence S; Harland, Karisa K; Ahmed, Azeemuddin; Fuller, Brian M; Mohr, Nicholas M

    2015-06-01

    The purposes of the study are to describe current practice of ventilation in a modern air medical system and to measure the association of ventilation strategy with subsequent ventilator care and acute respiratory distress syndrome (ARDS). Retrospective observational cohort study of intubated adult patients (n = 235) transported by a university-affiliated air medical transport service to a 711-bed tertiary academic center between July 2011 and May 2013. Low tidal volume ventilation was defined as tidal volumes less than or equal to 8 mL/kg predicted body weight. Multivariable regression was used to measure the association between prehospital tidal volume, hospital ventilation strategy, and ARDS. Most patients (57%) were ventilated solely with bag valve ventilation during transport. Mean tidal volume of mechanically ventilated patients was 8.6 mL/kg predicted body weight (SD, 0.2 mL/kg). Low tidal volume ventilation was used in 13% of patients. Patients receiving low tidal volume ventilation during air medical transport were more likely to receive low tidal volume ventilation in the emergency department (P tidal volume (P = .840). Low tidal volume ventilation was rare during air medical transport. Air transport ventilation strategy influenced subsequent ventilation but was not associated with ARDS. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Advanced Neutron Source enrichment study. Volume 2: Appendices -- Final report, Revision 12/94

    International Nuclear Information System (INIS)

    Bari, R.A.; Ludewig, H.; Weeks, J.

    1994-01-01

    A study has been performed of the impact on performance of using low enriched uranium (20% 235 U) or medium enriched uranium (35% 235 U) as an alternative fuel for the Advanced Neutron Source, which is currently designed to use uranium enriched to 93% 235 U. Higher fuel densities and larger volume cores were evaluated at the lower enrichments in terms of impact on neutron flux, safety, safeguards, technical feasibility, and cost. The feasibility of fabricating uranium silicide fuel at increasing material density was specifically addressed by a panel of international experts on research reactor fuels. The most viable alternative designs for the reactor at lower enrichments were identified and discussed. Several sensitivity analyses were performed to gain an understanding of the performance of the reactor at parametric values of power, fuel density, core volume, and enrichment that were interpolations between the boundary values imposed on the study or extrapolations from known technology. Volume 2 of this report contains 26 appendices containing results, meeting minutes, and fuel panel presentations. There are 26 appendices in this volume

  8. Effect of Progressive Volume-Based Overload During Plyometric Training on Explosive and Endurance Performance in Young Soccer Players.

    Science.gov (United States)

    Ramírez-Campillo, Rodrigo; Henríquez-Olguín, Carlos; Burgos, Carlos; Andrade, David C; Zapata, Daniel; Martínez, Cristian; Álvarez, Cristian; Baez, Eduardo I; Castro-Sepúlveda, Mauricio; Peñailillo, Luis; Izquierdo, Mikel

    2015-07-01

    The purpose of the study was to compare the effects of progressive volume-based overload with constant volume-based overload on muscle explosive and endurance performance adaptations during a biweekly short-term (i.e., 6 weeks) plyometric training intervention in young soccer players. Three groups of young soccer players (age 13.0 ± 2.3 years) were divided into: control (CG; n = 8) and plyometric training with (PPT; n = 8) and without (NPPT; n = 8) a progressive increase in volume (i.e., 16 jumps per leg per week, with an initial volume of 80 jumps per leg each session). Bilateral and unilateral horizontal and vertical countermovement jump with arms (CMJA), 20-cm drop jump reactive strength index (RSI20), maximal kicking velocity (MKV), 10-m sprint, change of direction speed (CODS), and Yo-Yo intermittent recovery level 1 test (Yo-Yo IR1) were measured. Although both experimental groups significantly increased CMJA, RSI20, CODS, and endurance performance, only PPT showed a significant improvement in MKV and 10-m sprint time. In addition, only PPT showed a significantly higher performance improvement in jumping, MKV, and Yo-Yo IR1 compared with CG. Also, PPT showed higher meaningful improvement compared with NPPT in all (except 1) jump performance measures. Furthermore, although PPT involved a higher total volume compared with NPPT, training efficiency (i.e., percentage change in performance/total jump volume) was similar between groups. Our results show that PPT and NPPT ensured significant improvement in muscle explosive and endurance performance measures. However, a progressive increase in plyometric training volume seems more advantageous to induce soccer-specific performance improvements.

  9. Mound cyclone incinerator. Volume I. Description and performance

    International Nuclear Information System (INIS)

    Klingler, L.M.

    1981-01-01

    The Mound cyclone incinerator was developed to fill a need for a simple, relaible incinerator for volume reduction of dry solid waste contaminated with plutonium-238. Although the basic design of the incinerator is for batch burning of solid combustible waste, the incinerator has also been adapted to volume reduction of other waste forms. Specialized waste feeding equipment enables continuous burning of both solid and liquid waste, including full scintillation vials. Modifications to the incinerator offgas system enable burning of waste contaminated with isotopes other than plutonium-238. This document presents the design and performance characteristics of the Mound Cyclone Incinerator for incineration of both solid and liquid waste. Suggestions are included for adaptation of the incinerator to specialized waste materials

  10. Mars power system concept definition study. Volume 1: Study results

    Science.gov (United States)

    Littman, Franklin D.

    1994-01-01

    A preliminary top level study was completed to define power system concepts applicable to Mars surface applications. This effort included definition of power system requirements and selection of power systems with the potential for high commonality. These power systems included dynamic isotope, Proton Exchange Membrane (PEM) regenerative fuel cell, sodium sulfur battery, photovoltaic, and reactor concepts. Design influencing factors were identified. Characterization studies were then done for each concept to determine system performance, size/volume, and mass. Operations studies were done to determine emplacement/deployment maintenance/servicing, and startup/shutdown requirements. Technology development roadmaps were written for each candidate power system (included in Volume 2). Example power system architectures were defined and compared on a mass basis. The dynamic isotope power system and nuclear reactor power system architectures had significantly lower total masses than the photovoltaic system architectures. Integrated development and deployment time phasing plans were completed for an example DIPS and reactor architecture option to determine the development strategies required to meet the mission scenario requirements.

  11. Semiautomatic regional segmentation to measure orbital fat volumes in thyroid-associated ophthalmopathy. A validation study.

    Science.gov (United States)

    Comerci, M; Elefante, A; Strianese, D; Senese, R; Bonavolontà, P; Alfano, B; Bonavolontà, B; Brunetti, A

    2013-08-01

    This study was designed to validate a novel semi-automated segmentation method to measure regional intra-orbital fat tissue volume in Graves' ophthalmopathy. Twenty-four orbits from 12 patients with Graves' ophthalmopathy, 24 orbits from 12 controls, ten orbits from five MRI study simulations and two orbits from a digital model were used. Following manual region of interest definition of the orbital volumes performed by two operators with different levels of expertise, an automated procedure calculated intra-orbital fat tissue volumes (global and regional, with automated definition of four quadrants). In patients with Graves' disease, clinical activity score and degree of exophthalmos were measured and correlated with intra-orbital fat volumes. Operator performance was evaluated and statistical analysis of the measurements was performed. Accurate intra-orbital fat volume measurements were obtained with coefficients of variation below 5%. The mean operator difference in total fat volume measurements was 0.56%. Patients had significantly higher intra-orbital fat volumes than controls (p<0.001 using Student's t test). Fat volumes and clinical score were significantly correlated (p<0.001). The semi-automated method described here can provide accurate, reproducible intra-orbital fat measurements with low inter-operator variation and good correlation with clinical data.

  12. Basic life support and automated external defibrillator skills among ambulance personnel: a manikin study performed in a rural low-volume ambulance setting

    Directory of Open Access Journals (Sweden)

    Nielsen Anne

    2012-05-01

    Full Text Available Abstract Background Ambulance personnel play an essential role in the ‘Chain of Survival’. The prognosis after out-of-hospital cardiac arrest was dismal on a rural Danish island and in this study we assessed the cardiopulmonary resuscitation performance of ambulance personnel on that island. Methods The Basic Life Support (BLS and Automated External Defibrillator (AED skills of the ambulance personnel were tested in a simulated cardiac arrest. Points were given according to a scoring sheet. One sample t test was used to analyze the deviation from optimal care according to the 2005 guidelines. After each assessment, individual feedback was given. Results On 3 consecutive days, we assessed the individual EMS teams responding to OHCA on the island. Overall, 70% of the maximal points were achieved. The hands-off ratio was 40%. Correct compression/ventilation ratio (30:2 was used by 80%. A mean compression depth of 40–50 mm was achieved by 55% and the mean compression depth was 42 mm (SD 7 mm. The mean compression rate was 123 per min (SD 15/min. The mean tidal volume was 746 ml (SD 221 ml. Only the mean tidal volume deviated significantly from the recommended (p = 0.01. During the rhythm analysis, 65% did not perform any visual or verbal safety check. Conclusion The EMS providers achieved 70% of the maximal points. Tidal volumes were larger than recommended when mask ventilation was applied. Chest compression depth was optimally performed by 55% of the staff. Defibrillation safety checks were not performed in 65% of EMS providers.

  13. Los Alamos Controlled Air Incinerator for radioactive waste. Volume I. Rationale, process, equipment, performance, and recommendations

    International Nuclear Information System (INIS)

    Neuls, A.S.; Draper, W.E.; Koenig, R.A.; Newmyer, J.M.; Warner, C.L.

    1982-08-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawing, specifications, calculations, and costs. It aids duplication of the process at other facilities

  14. Los Alamos Controlled Air Incinerator for radioactive waste. Volume I. Rationale, process, equipment, performance, and recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Neuls, A.S.; Draper, W.E.; Koenig, R.A.; Newmyer, J.M.; Warner, C.L.

    1982-08-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawing, specifications, calculations, and costs. It aids duplication of the process at other facilities.

  15. Critical Propulsion Components. Volume 1; Summary, Introduction, and Propulsion Systems Studies

    Science.gov (United States)

    2005-01-01

    Several studies have concluded that a supersonic aircraft, if environmentally acceptable and economically viable, could successfully compete in the 21st century marketplace. However, before industry can commit to what is estimated as a 15 to 20 billion dollar investment, several barrier issues must be resolved. In an effort to address these barrier issues, NASA and Industry teamed to form the High-Speed Research (HSR) program. As part of this program, the Critical Propulsion Components (CPC) element was created and assigned the task of developing those propulsion component technologies necessary to: (1) reduce cruise emissions by a factor of 10 and (2) meet the ever-increasing airport noise restrictions with an economically viable propulsion system. The CPC-identified critical components were ultra-low emission combustors, low-noise/high-performance exhaust nozzles, low-noise fans, and stable/high-performance inlets. Propulsion cycle studies (coordinated with NASA Langley Research Center sponsored airplane studies) were conducted throughout this CPC program to help evaluate candidate components and select the best concepts for the more complex and larger scale research efforts. The propulsion cycle and components ultimately selected were a mixed-flow turbofan (MFTF) engine employing a lean, premixed, prevaporized (LPP) combustor coupled to a two-dimensional mixed compression inlet and a two-dimensional mixer/ejector nozzle. Due to the large amount of material presented in this report, it was prepared in four volumes; Volume 1: Summary, Introduction, and Propulsion System Studies, Volume 2: Combustor, Volume 3: Exhaust Nozzle, and Volume 4: Inlet and Fan/ Inlet Acoustic Team.

  16. Performance enhancement of direct ethanol fuel cell using Nafion composites with high volume fraction of titania

    Science.gov (United States)

    Matos, B. R.; Isidoro, R. A.; Santiago, E. I.; Fonseca, F. C.

    2014-12-01

    The present study reports on the performance enhancement of direct ethanol fuel cell (DEFC) at 130 °C with Nafion-titania composite electrolytes prepared by sol-gel technique and containing high volume fractions of the ceramic phase. It is found that for high volume fractions of titania (>10 vol%) the ethanol uptake of composites is largely reduced while the proton conductivity at high-temperatures is weakly dependent on the titania content. Such tradeoff between alcohol uptake and conductivity resulted in a boost of DEFC performance at high temperatures using Nafion-titania composites with high fraction of the inorganic phase.

  17. Depressed left ventricular performance. Response to volume infusion in patients with sepsis and septic shock

    International Nuclear Information System (INIS)

    Ognibene, F.P.; Parker, M.M.; Natanson, C.; Shelhamer, J.H.; Parrillo, J.E.

    1988-01-01

    Volume infusion, to increase preload and to enhance ventricular performance, is accepted as initial management of septic shock. Recent evidence has demonstrated depressed myocardial function in human septic shock. We analyzed left ventricular performance during volume infusion using serial data from simultaneously obtained pulmonary artery catheter hemodynamic measurements and radionuclide cineangiography. Critically ill control subjects (n = 14), patients with sepsis but without shock (n = 21), and patients with septic shock (n = 21) had prevolume infusion hemodynamic measurements determined and received statistically similar volumes of fluid resulting in similar increases in pulmonary capillary wedge pressure. There was a strong trend (p = 0.004) toward less of a change in left ventricular stroke work index (LVSWI) after volume infusion in patients with sepsis and septic shock compared with control subjects. The LVSWI response after volume infusion was significantly less in patients with septic shock when compared with critically ill control subjects (p less than 0.05). These data demonstrate significantly altered ventricular performance, as measured by LVSWI, in response to volume infusion in patients with septic shock

  18. Can Emergency Physicians Perform Common Carotid Doppler Flow Measurements to Assess Volume Responsiveness?

    Directory of Open Access Journals (Sweden)

    Stolz, Lori A.

    2015-02-01

    Full Text Available Introduction: Common carotid flow measurements may be clinically useful to determine volume responsiveness. The objective of this study was to assess the ability of emergency physicians (EP to obtain sonographic images and measurements of the common carotid artery velocity time integral (VTi for potential use in assessing volume responsiveness in the clinical setting. Methods: In this prospective observational study, we showed a five-minute instructional video demonstrating a technique to obtain common carotid ultrasound images and measure the common carotid VTi to emergency medicine (EM residents. Participants were then asked to image the common carotid artery and obtain VTi measurements. Expert sonographers observed participants imaging in real time and recorded their performance on nine performance measures. An expert sonographer graded image quality. Participants were timed and answered questions regarding ease of examination and their confidence in obtaining the images. Results: A total of 30 EM residents participated in this study and each performed the examination twice. Average time required to complete one examination was 2.9 minutes (95% CI [2.4-3.4 min]. Participants successfully completed all performance measures greater than 75% of the time, with the exception of obtaining measurements during systole, which was completed in 65% of examinations. Median resident overall confidence in accurately performing carotid VTi measurements was 3 (on a scale of 1 [not confident] to 5 [confident]. Conclusion: EM residents at our institution learned the technique for obtaining common carotid artery Doppler flow measurements after viewing a brief instructional video. When assessed at performing this examination, they completed several performance measures with greater than 75% success. No differences were found between novice and experienced groups. [West J Emerg Med. 2015;16(2:255–259.

  19. Impact of Formulas, Language and Instruction on Student Performance on Cost-Volume-Profit Problems

    Science.gov (United States)

    Johnson, Benny G.; Sargent, Carol Springer

    2014-01-01

    This study investigated how three factors impacted performance on cost-volume-profit homework problems: language, formula use, and instruction. Students enrolled in Introduction to Financial Accounting (the first principles of accounting course) and Managerial Accounting (the second principles of accounting course) from eight different US colleges…

  20. Short-term performance effects of three different low-volume strength-training programmes in college male soccer players

    DEFF Research Database (Denmark)

    Brito, João; Vasconcellos, Fabrício; Oliveira, José

    2014-01-01

    This study aimed to analyse the short-term performance effects of three in-season low-volume strength-training programmes in college male soccer players. Fifty-seven male college soccer players (age: 20.31.6 years) were randomly assigned to a resistance-training group (n=12), plyometric training.......001) compared with the control group. No differences were observed in 5-m sprint and agility performances (p>0.05). Overall, the results suggest that in-season low-volume strength training is adequate for developing strength and speed in soccer players....

  1. PRT Impact Study Pre-PRT Phase : Volume 1. Travel Analysis.

    Science.gov (United States)

    1976-03-01

    Part of a three-volume work, this report describes the analysis performed on travel data collected for the Pre-PRT Impact Study. The data analyzed consist of travel behavior, travel patterns, model utilization and travel costs of various modes of tra...

  2. Development of the NRC`s Human Performance Investigation Process (HPIP). Volume 2, Investigators`s Manual

    Energy Technology Data Exchange (ETDEWEB)

    Paradies, M.; Unger, L. [System Improvements, Inc., Knoxville, TN (United States); Haas, P.; Terranova, M. [Concord Associates, Inc., Knoxville, TN (United States)

    1993-10-01

    The three volumes of this report detail a standard investigation process for use by US Nuclear Regulatory Commission (NRC) personnel when investigating human performance related events at nuclear power plants. The process, called the Human Performance Investigation Process (HPIP), was developed to meet the special needs of NRC personnel, especially NRC resident and regional inspectors. HPIP is a systematic investigation process combining current procedures and field practices, expert experience, NRC human performance research, and applicable investigation techniques. The process is easy to learn and helps NRC personnel perform better field investigations of the root causes of human performance problems. The human performance data gathered through such investigations provides a better understanding of the human performance issues that cause event at nuclear power plants. This document, Volume II, is a field manual for use by investigators when performing event investigations. Volume II includes the HPIP Procedure, the HPIP Modules, and Appendices that provide extensive documentation of each investigation technique.

  3. Advanced Neutron Source enrichment study -- Volume 1: Main report. Final report, Revision 12/94

    International Nuclear Information System (INIS)

    Bari, R.A.; Ludewig, H.; Weeks, J.

    1994-01-01

    A study has been performed of the impact on performance of using low enriched uranium (20% 235 U) or medium enriched uranium (35% 235 U) as an alternative fuel for the Advanced Neutron Source, which is currently designed to use uranium enriched to 93% 235 U. Higher fuel densities and larger volume cores were evaluated at the lower enrichments in terms of impact on neutron flux, safety, safeguards, technical feasibility, and cost. The feasibility of fabricating uranium silicide fuel at increasing material density was specifically addressed by a panel of international experts on research reactor fuels. The most viable alternative designs for the reactor at lower enrichments were identified and discussed. Several sensitivity analyses were performed to gain an understanding of the performance of the reactor at parametric values of power, fuel density, core volume, and enrichment that were interpolations between the boundary values imposed on the study or extrapolations from known technology. Volume 2 of this report contains 26 appendices containing results, meeting minutes, and fuel panel presentations

  4. Low Cost High Performance Generator Technology Program. Volume 4. Mission application study

    International Nuclear Information System (INIS)

    1975-07-01

    Results of initial efforts to investigate application of selenide thermoelectric RTG's to specific missions as well as an indication of development requirements to enable satisfaction of emerging RTG performance criteria are presented. Potential mission applications in DoD such as SURVSATCOM, Advance Defense Support Program, Laser Communication Satellite, Satellite Data System, Global Positioning Satellite, Deep Space Surveillance Satellite, and Unmanned Free Swimming Submersible illustrate power requirements in the range of 500 to 1000 W. In contrast, the NASA applications require lower power ranging from 50 W for outer planetary atmospheric probes to about 200 W for spacecraft flights to Jupiter and other outer planets. The launch dates for most of these prospective missions is circa 1980, a requirement roughly compatible with selenide thermoelectric and heat source technology development. A discussion of safety criteria is included to give emphasis to the requirements for heat source design. In addition, the observation is made that the potential accident environments of all launch vehicles are similar so that a reasonable composite set of design specifications may be derived to satisfy almost all applications. Details of the LCHPG application potential is afforded by three designs: an 80 W RTG using improved selenide thermoelectric material, a 55 to 65 W LCHPG using current and improved selenide materials, and the final 500 W LCHPG as reported in Volume 2. The final results of the LCHPG design study have shown that in general, all missions can expect an LCHPG design which yields 10 percent efficiency at 3 W/lb with the current standard selenide thermoelectric materials, with growth potential to 14 percent at greater than 4 W/lb in the mid 1980's time frame

  5. Development of the NRC`s Human Performance Investigation Process (HPIP). Volume 3, Development documentation

    Energy Technology Data Exchange (ETDEWEB)

    Paradies, M.; Unger, L. [System Improvements, Inc., Knoxville, TN (United States); Haas, P.; Terranova, M. [Concord Associates, Inc., Knoxville, TN (United States)

    1993-10-01

    The three volumes of this report detail a standard investigation process for use by US Nuclear Regulatory Commission (NRC) personnel when investigating human performance related events at nuclear power plants. The process, called the Human Performance Investigation Process (HPIP), was developed to meet the special needs of NRC personnel, especially NRC resident and regional inspectors. HPIP is a systematic investigation process combining current procedures and field practices, expert experience, NRC human performance research, and applicable investigation techniques. The process is easy to learn and helps NRC personnel perform better field investigations of the root causes of human performance problems. The human performance data gathered through such investigations provides a better understanding of the human performance issues that cause events at nuclear power plants. This document, Volume III, is a detailed documentation of the development effort and the pilot training program.

  6. Phantom study on three-dimensional target volume delineation by PET/CT-based auto-contouring

    International Nuclear Information System (INIS)

    Zhang, Tiejiao; Sakaguchi, Yuichi; Mitsumoto, Katsuhiko; Mitsumoto, Tatsuya; Sasaki, Masayuki; Tachiya, Yosuke; Ohya, Nobuyoshi

    2010-01-01

    The aim of this study was to determine an appropriate threshold value for delineation of the target volume in positron emission tomography (PET)/CT and to investigate whether we could delineate a target volume by phantom studies. A phantom consisted of six spheres (φ10-37 mm) filled with 18 F solution. Data acquisition was performed PET/CT in non-motion and motion status with high 18 F solution and in non-motion status with low 18 F solution. In non-motion phantom experiments, we determined two types of threshold value, an absolute SUV (T SUV ) and a percentage of the maximum SUV (T % ). Delineation using threshold values was applied for all spheres and for selected large spheres (a diameter of 22 mm or larger). In motion phantom experiments, data acquisition was performed in a static mode (sPET) and a gated mode (gPET). CT scanning was performed with helical CT (HCT) and 4-dimentional CT (4DCT). The appropriate threshold values were aT % =27% and aT SUV =2.4 for all spheres, and sT % =30% and sT SUV =4.3 for selected spheres. For all spheres in sPET/HCT in motion, the delineated volumes were 84%-129% by the aT % and 34%-127% by the aT SUV . In gPET/4DCT in motion, the delineated volumes were 94-103% by the aT % and 51-131% by the aT SUV . For low radioactivity spheres, the delineated volumes were all underestimated. A threshold value of T % =27% was proposed for auto-contouring of lung tumors. Our results also suggested that the respiratory gated data acquisition should be performed in both PET and CT for target volume delineation. (author)

  7. POWER-GEN '90 conference papers: Volume 7 (Fossil plant performance availability and improvement) and Volume 8 (Nuclear power issues)

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    This is book 4 of papers presented at the Third International Exhibition and Conference for the Power Generation Industries, December 4-6, 1990. This book contains Volume 7, Fossil Plant Performance Availability and Improvement, and Volume 8, Nuclear Power Issues. The topics of the papers include computer applications in plant operations and maintenance, managing aging plants, plant improvements, plant operations and maintenance, the future of nuclear power, achieving cost effective plant operation, managing nuclear plant aging and license renewal, and the factors affecting a decision to build a new nuclear plant

  8. Research Studies Index. Authors and Subjects. Volume 1 through Volume 43 (1929-1975).

    Science.gov (United States)

    Drazan, Joseph, Comp.; Scott, Paula, Comp.

    This volume contains author and subject indexes for volumes 1 through 43 (1929-1975) of "Research Studies," a scholarly, multi-disciplinary quarterly published at Washington State University. Each author index entry includes the title, volume, and inclusive pagination of the article. The subject index is a keyword-out-of-context…

  9. Lattice study of finite volume effect in HVP for muon g-2

    Directory of Open Access Journals (Sweden)

    Izubuchi Taku

    2018-01-01

    Full Text Available We study the finite volume effect of the hadronic vacuum polarization contribution to muon g-2, aμhvp,in lattice QCD by comparison with two different volumes, L4 = (5.44 and (8.14 fm4, at physical pion. We perform the lattice computation of highly precise vector-vector current correlator with optimized AMA technique on Nf = 2 + 1 PACS gauge configurations in Wilson-clover fermion and stout smeared gluon action at one lattice cut-off, a−1 = 2.33 GeV. We compare two integrals of aμhvp, momentum integral and time-slice summation, on the lattice and numerically show that the different size of finite volume effect appears between two methods. We also discuss the effect of backward-state propagation into the result of aμhvp with the different boundary condition. Our model-independent study suggest that the lattice computation at physical pion is important for correct estimate of finite volume and other lattice systematics in aμhvp.

  10. Lattice study of finite volume effect in HVP for muon g-2

    Science.gov (United States)

    Izubuchi, Taku; Kuramashi, Yoshinobu; Lehner, Christoph; Shintani, Eigo

    2018-03-01

    We study the finite volume effect of the hadronic vacuum polarization contribution to muon g-2, aμhvp, in lattice QCD by comparison with two different volumes, L4 = (5.4)4 and (8.1)4 fm4, at physical pion. We perform the lattice computation of highly precise vector-vector current correlator with optimized AMA technique on Nf = 2 + 1 PACS gauge configurations in Wilson-clover fermion and stout smeared gluon action at one lattice cut-off, a-1 = 2.33 GeV. We compare two integrals of aμhvp, momentum integral and time-slice summation, on the lattice and numerically show that the different size of finite volume effect appears between two methods. We also discuss the effect of backward-state propagation into the result of aμhvp with the different boundary condition. Our model-independent study suggest that the lattice computation at physical pion is important for correct estimate of finite volume and other lattice systematics in aμhvp.

  11. Importance of the test volume on the lag phase in biodegradation studies

    DEFF Research Database (Denmark)

    Ingerslev, F.; Torang, Lars; Nyholm, Niels

    2000-01-01

    , degradation failed randomly. Our findings are partly explained by the hypotheses that a sufficient total amount as well as a sufficient concentration of specifically degrading microorganisms or consortia of bacteria must be present initially for biodegradation to get started, from which follows that with too......Increasing the total volume of test medium resulted in decreased lag times (TL) in biodegradability shake flask batch tests conducted with either surface water or with synthetic mineral medium inoculated with supernatant from settled activated sludge. Experiments were performed with test volumes...... small inoculations or with too small test volumes, biodegradation may fail randomly. A straightforward practical implication of the findings is that the test volume in biodegradability tests can significantly influence the lag time and thus sometimes be decisive for the outcome in biodegradation studies....

  12. Delayed recall, hippocampal volume and Alzheimer neuropathology: findings from the Nun Study.

    Science.gov (United States)

    Mortimer, J A; Gosche, K M; Riley, K P; Markesbery, W R; Snowdon, D A

    2004-02-10

    To examine the associations of hippocampal volume and the severity of neurofibrillary lesions determined at autopsy with delayed verbal recall performance evaluated an average of 1 year prior to death. Hippocampal volumes were computed using postmortem brain MRI from the first 56 scanned participants of the Nun Study. Quantitative neuropathologic studies included lesion counts, Braak staging, and determination of whether neuropathologic criteria for Alzheimer disease (AD) were met. Multiple regression was used to assess the association of hippocampal volume and neuropathologic lesions with the number of words (out of 10) recalled on the Consortium to Establish a Registry for Alzheimer's Disease Delayed Word Recall Test administered an average of 1 year prior to death. When entered separately, hippocampal volume, Braak stage, and the mean neurofibrillary tangle counts in the CA-1 region of the hippocampus and the subiculum were strongly associated with the number of words recalled after a delay, adjusting for age and education. When hippocampal volume was entered together with each neuropathologic index, only hippocampal volume retained a significant association with the delayed recall measure. The association between hippocampal volume and the number of words recalled was present in both demented and nondemented individuals as well as in those with and without substantial AD neurofibrillary pathology. The association of neurofibrillary tangles with delayed verbal recall may reflect associated hippocampal atrophy.

  13. Organ volume estimation using SPECT

    CERN Document Server

    Zaidi, H

    1996-01-01

    Knowledge of in vivo thyroid volume has both diagnostic and therapeutic importance and could lead to a more precise quantification of absolute activity contained in the thyroid gland. In order to improve single-photon emission computed tomography (SPECT) quantitation, attenuation correction was performed according to Chang's algorithm. The dual-window method was used for scatter subtraction. We used a Monte Carlo simulation of the SPECT system to accurately determine the scatter multiplier factor k. Volume estimation using SPECT was performed by summing up the volume elements (voxels) lying within the contour of the object, determined by a fixed threshold and the gray level histogram (GLH) method. Thyroid phantom and patient studies were performed and the influence of 1) fixed thresholding, 2) automatic thresholding, 3) attenuation, 4) scatter, and 5) reconstruction filter were investigated. This study shows that accurate volume estimation of the thyroid gland is feasible when accurate corrections are perform...

  14. Temporal lobe volume predicts Wada memory test performance in patients with mesial temporal sclerosis.

    Science.gov (United States)

    Ding, Kan; Gong, Yunhua; Modur, Pradeep N; Diaz-Arrastia, Ramon; Agostini, Mark; Gupta, Puneet; McColl, Roderick; Hays, Ryan; Van Ness, Paul

    2016-02-01

    The Wada test is widely used in the presurgical evaluation of potential temporal lobectomy patients to predict postoperative memory function. Expected asymmetry (EA), defined as Wada memory lateralized to the nonsurgical hemisphere, or a higher score after injection of the surgical hemisphere would be considered favorable in terms of postoperative memory outcome. However, in some cases, nonlateralized memory (NM) results, with no appreciable asymmetry, may occur because of impaired scores after both injections, often leading to denial of surgery. The reason for such nonlateralized Wada memory in patients with intractable temporal lobe epilepsy (TLE) remains unclear. Given that quantitative morphometric magnetic resonance imaging studies in TLE patients have shown bilateral regional atrophy in temporal and extratemporal structures, we hypothesized that the volume loss in contralateral temporal structures could contribute to nonlateralized Wada memory performance. To investigate this, we examined the relationship between the volume changes of temporal structures and Wada memory scores in patients with intractable TLE with mesial temporal sclerosis (MTS) using an age- and gender-matched control group. Memory was considered nonlateralized if the absolute difference in the total correct recall scores between ipsilateral and contralateral injections was memory was lateralized in 15 and nonlateralized in 6 patients, with all the nonlateralized scores being observed in left TLE. The recall scores after ipsilateral injection were significantly lower in patients with an NM profile than an EA profile (23 ± 14% vs. 59 ± 18% correct recall, p ≤ 0.001). However, the recall scores after contralateral injection were low but similar between the two groups (25 ± 17% vs. 25 ± 15% correct recall, p=0.97). Compared to controls, all the patients showed greater volume loss in the temporal regions. However, patients with a NM profile showed significantly more volume loss than those

  15. Postmenopausal hormone therapy and regional brain volumes: the WHIMS-MRI Study.

    Science.gov (United States)

    Resnick, S M; Espeland, M A; Jaramillo, S A; Hirsch, C; Stefanick, M L; Murray, A M; Ockene, J; Davatzikos, C

    2009-01-13

    To determine whether menopausal hormone therapy (HT) affects regional brain volumes, including hippocampal and frontal regions. Brain MRI scans were obtained in a subset of 1,403 women aged 71-89 years who participated in the Women's Health Initiative Memory Study (WHIMS). WHIMS was an ancillary study to the Women's Health Initiative, which consisted of two randomized, placebo-controlled trials: 0.625 mg conjugated equine estrogens (CEE) with or without 2.5 mg medroxyprogesterone acetate (MPA) in one daily tablet. Scans were performed, on average, 3.0 years post-trial for the CEE + MPA trial and 1.4 years post-trial for the CEE-Alone trial; average on-trial follow-up intervals were 4.0 years for CEE + MPA and 5.6 years for CEE-Alone. Total brain, ventricular, hippocampal, and frontal lobe volumes, adjusted for age, clinic site, estimated intracranial volume, and dementia risk factors, were the main outcome variables. Compared with placebo, covariate-adjusted mean frontal lobe volume was 2.37 cm(3) lower among women assigned to HT (p = 0.004), mean hippocampal volume was slightly (0.10 cm(3)) lower (p = 0.05), and differences in total brain volume approached significance (p = 0.07). Results were similar for CEE + MPA and CEE-Alone. HT-associated reductions in hippocampal volumes were greatest in women with the lowest baseline Modified Mini-Mental State Examination scores (scores equine estrogens with or without MPA are associated with greater brain atrophy among women aged 65 years and older; however, the adverse effects are most evident in women experiencing cognitive deficits before initiating hormone therapy.

  16. Performance of a parallel plate volume calorimeter prototype

    International Nuclear Information System (INIS)

    Arefiev, A.; Bencze, Gy.L.; Bizzeti, A.; Choumilov, E.; Civinini, C; D'Alessandro, R.; Ferrando, A.; Fouz, M.C.; Iglesias, A.; Ivochkin, V.; Josa, M.I.; Malinin, A.; Meschini, M.; Misyura, S.; Pojidaev, V.; Salicio, J.M.; Sikler, F.

    1995-01-01

    An iron/gas parallel plate volume calorimeter prototype, working in the avalanche mode, has been tested using electrons of 20 to 150 GeV/c momentum with high voltages varying from 5400 to 5600 V (electric fields ranging from 36 to 37 KV/cm), and a gas mixture of CF4/CO, (80/20%). The collected charge was measured as a function of the high voltage and of the electron energy. The energy resolution was also measured. Comparisons are made with Monte-Carlo predictions. Agreement between data and simulation allows the calculation of the expected performance of a full size calorimeter. (Author)

  17. Performance of a parallel plate volume calorimeter prototype

    International Nuclear Information System (INIS)

    Arefiev, A.; Bencze, G.L.; Bizzeti, A.

    1995-09-01

    An iron/gas parallel plate volume calorimeter prototype, working in the avalanche mode, has been tested using electrons of 20 to 150 GeV/c momentum with high voltages varying from 5400 to 5600 V (electric fields ranging from 36 to 37 KV/cm), and a gas mixture of CF 4 /CO 2 (80/20%). The collected charge was measured as a function of the high voltage and of the electron energy. The energy resolution was also measured. Comparisons are made with Monte-Carlo predictions. Agreement between data and simulation allows the calculation of the expected performance of a full size calorimeter

  18. Effects of DARPP-32 Genetic Variation on Prefrontal Cortex Volume and Episodic Memory Performance

    Directory of Open Access Journals (Sweden)

    Ninni Persson

    2017-05-01

    Full Text Available Despite evidence of a fundamental role of DARPP-32 in integrating dopamine and glutamate signaling, studies examining gene coding for DARPP-32 in relation to neural and behavioral correlates in humans are scarce. Post mortem findings suggest genotype specific expressions of DARPP-32 in the dorsal frontal lobes. Therefore, we investigated the effects of genomic variation in DARPP-32 coding on frontal lobe volumes and episodic memory. Volumetric data from the dorsolateral (DLPFC, and visual cortices (VC were obtained from 61 younger and older adults (♀54%. The major homozygote G, T, or A genotypes in single nucleotide polymorphisms (SNPs: rs879606; rs907094; rs3764352, the two latter in complete linkage disequilibrium, at the DARPP-32 regulating PPP1R1B gene, influenced frontal gray matter volume and episodic memory (EM. Homozygous carriers of allelic variants with lower DARPP-32 expression had an overall larger prefrontal volume in addition to greater EM recall accuracy after accounting for the influence of age. The SNPs did not influence VC volume. The genetic effects on DLPFC were greater in young adults and selective to this group for EM. Our findings suggest that genomic variation maps onto individual differences in frontal brain volumes and cognitive functions. Larger DLPFC volumes were also related to better EM performance, suggesting that gene-related differences in frontal gray matter may contribute to individual differences in EM. These results need further replication from experimental and longitudinal reports to determine directions of causality.

  19. Larger right posterior parietal volume in action video game experts: a behavioral and voxel-based morphometry (VBM study.

    Directory of Open Access Journals (Sweden)

    Satoshi Tanaka

    Full Text Available Recent studies suggest that action video game players exhibit superior performance in visuospatial cognitive tasks compared with non-game players. However, the neural basis underlying this visuospatial cognitive performance advantage remains largely unknown. The present human behavioral and imaging study compared gray matter volume in action video game experts and non-experts using structural magnetic resonance imaging and voxel-based morphometry analysis. The results revealed significantly larger gray matter volume in the right posterior parietal cortex in experts compared with non-experts. Furthermore, the larger gray matter volume in the right posterior parietal cortex significantly correlated with individual performance in a visual working memory task in experts. These results suggest that differences in brain structure may be linked to extensive video game play, leading to superior visuospatial cognitive performance in action video game experts.

  20. Performance Prediction Modelling for Flexible Pavement on Low Volume Roads Using Multiple Linear Regression Analysis

    Directory of Open Access Journals (Sweden)

    C. Makendran

    2015-01-01

    Full Text Available Prediction models for low volume village roads in India are developed to evaluate the progression of different types of distress such as roughness, cracking, and potholes. Even though the Government of India is investing huge quantum of money on road construction every year, poor control over the quality of road construction and its subsequent maintenance is leading to the faster road deterioration. In this regard, it is essential that scientific maintenance procedures are to be evolved on the basis of performance of low volume flexible pavements. Considering the above, an attempt has been made in this research endeavor to develop prediction models to understand the progression of roughness, cracking, and potholes in flexible pavements exposed to least or nil routine maintenance. Distress data were collected from the low volume rural roads covering about 173 stretches spread across Tamil Nadu state in India. Based on the above collected data, distress prediction models have been developed using multiple linear regression analysis. Further, the models have been validated using independent field data. It can be concluded that the models developed in this study can serve as useful tools for the practicing engineers maintaining flexible pavements on low volume roads.

  1. A comparative study of self-consolidating concretes incorporating high-volume natural pozzolan or high-volume fly ash

    KAUST Repository

    Celik, Kemal; Meral, Cagla; Mancio, Mauricio; Mehta, P. Kumar; Monteiro, Paulo J.M.

    2014-01-01

    The purpose of this study is to compare the effects of Portland cement replacement on the strength and durability of self-consolidating concretes (SSC). The two replacement materials used are high-volume natural pozzolan (HVNP), a Saudi Arabian aluminum-silica rich basaltic glass and high-volume Class-F fly ash (HVFAF), from Jim Bridger Power Plant, Wyoming, US. As an extension of the study, limestone filler (LF) is also used to replace Portland cement, alongside HVNP or HVFAF, forming ternary blends. Along with compressive strength tests, non-steady state chloride migration and gas permeability tests were performed, as durability indicators, on SCC specimens. The results were compared to two reference concretes; 100% ordinary Portland cement (OPC) and 85% OPC - 15% LF by mass. The HVNP and HVFAF concrete mixes showed strength and durability results comparable to those of the reference concretes; identifying that both can effectively be used to produce low-cost and environmental friendly SCC. © 2013 Elsevier Ltd. All rights reserved.

  2. A comparative study of self-consolidating concretes incorporating high-volume natural pozzolan or high-volume fly ash

    KAUST Repository

    Celik, Kemal

    2014-09-01

    The purpose of this study is to compare the effects of Portland cement replacement on the strength and durability of self-consolidating concretes (SSC). The two replacement materials used are high-volume natural pozzolan (HVNP), a Saudi Arabian aluminum-silica rich basaltic glass and high-volume Class-F fly ash (HVFAF), from Jim Bridger Power Plant, Wyoming, US. As an extension of the study, limestone filler (LF) is also used to replace Portland cement, alongside HVNP or HVFAF, forming ternary blends. Along with compressive strength tests, non-steady state chloride migration and gas permeability tests were performed, as durability indicators, on SCC specimens. The results were compared to two reference concretes; 100% ordinary Portland cement (OPC) and 85% OPC - 15% LF by mass. The HVNP and HVFAF concrete mixes showed strength and durability results comparable to those of the reference concretes; identifying that both can effectively be used to produce low-cost and environmental friendly SCC. © 2013 Elsevier Ltd. All rights reserved.

  3. Volume Fraction Dependent Thermal Performance of UAlx-Al Dispersion Target

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Eui Hyun; Tahk, Young Wook; Kim, Hyun Jung; Oh, Jae Yong; Yim, Jeong Sik [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Unlike U-Al alloys, properties of UAl{sub x}-Al dispersion target can be highly sensitive to volume fraction of UAlx in a target meat due to the interface resistance between target particles and matrix. The interface resistance effects on properties of the target meat including thermal conductivity, thermal expansion coefficient, specific heat, elastic modulus and so on. Thermal performances of a dispersion target meat were theoretically evaluated under normal operation condition of KJRR (Kijang Research Reactor) during short effective full power days (EFPD) of 7 days, based on reported measured thermal conductivities of UAl{sub x}-Al dispersion fuels. Effective thermal conductivity determines maximum temperature of dispersion target plate. And for that volume fraction of UAlx in target meat has to be determined considering manufacturing of target plate without degradation of physical and mechanical characteristics.

  4. Low Cost High Performance Generator Technology Program. Volume 2. Design study

    International Nuclear Information System (INIS)

    1975-06-01

    The systems studies directed towards up-rating the performance of an RTG using selenide thermoelectrics and a heat source with improved safety are reported. The resulting generator design, designated LCHPG, exhibits conversion efficiency of greater than 10 percent, a specific power of 3 W/lb., and a cost of $6,000/W(e). In the course of system analyses, the significant development activities required to achieve this performance by the 1980 time period are identified

  5. ACUTE EFFECTS OF STATIC STRETCHING, DYNAMIC EXERCISES, AND HIGH VOLUME UPPER EXTREMITY PLYOMETRIC ACTIVITY ON TENNIS SERVE PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Ertugrul Gelen

    2012-12-01

    Full Text Available The purpose of this study was to compare the acute effects of static stretching; dynamic exercises and high volume upper extremity plyometric activity on tennis serve performance. Twenty-six elite young tennis players (15.1 ± 4.2 years, 167.9 ± 5.8 cm and 61.6 ± 8.1 kg performed 4 different warm-up (WU routines in a random order on non-consecutive days. The WU methods consisted of traditional WU (jogging, rally and serve practice (TRAD; traditional WU and static stretching (TRSS; traditional WU and dynamic exercise (TRDE; and traditional WU and high volume upper extremity plyometric activity (TRPLYP. Following each WU session, subjects were tested on a tennis serve ball speed test. TRAD, TRSS, TRDE and TRPLYO were compared by repeated measurement analyses of variance and post-hoc comparisons. In this study a 1 to 3 percent increase in tennis serve ball speed was recorded in TRDE and TRPLYO when compared to TRAD (p 0.05. ICCs for ball speed showed strong reliability (0.82 to 0.93 for the ball speed measurements.The results of this study indicate that dynamic and high volume upper extremity plyometric WU activities are likely beneficial to serve speed of elite junior tennis players.

  6. Field performance of stress-laminated timber bridges on low-volume roads

    Science.gov (United States)

    M. A. Ritter; J. P. Wacker; S. R. Duwadi

    1995-01-01

    Stress-laminated timber bridges were first introduced in the United States in the late 1980s. Since that time, the concept of stress-laminating has received a great deal of attention and hundreds of bridges have been built. Most of these bridges are located on rural low-volume roads. To evaluate the performance of stress-laminated bridges, the United States Department...

  7. Quantifying normal ankle joint volume: An anatomic study

    Directory of Open Access Journals (Sweden)

    Draeger Reid

    2009-01-01

    Full Text Available Background: Many therapeutic and diagnostic modalities such as intraarticular injections, arthrography and ankle arthroscopy require introduction of fluid into the ankle joint. Little data are currently available in the literature regarding the maximal volume of normal, nonpathologic, human ankle joints. The purpose of this study was to measure the volume of normal human ankle joints. Materials and Methods: A fluoroscopic guided needle was passed into nine cadaveric adult ankle joints. The needle was connected to an intracompartmental pressure measurement device. A radiopaque dye was introduced into the joint in 2 mL boluses, while pressure measurements were recorded. Fluid was injected into the joint until three consecutive pressure measurements were similar, signifying a maximal joint volume. Results: The mean maximum ankle joint volume was 20.9 ± 4.9 mL (range, 16-30 mL. The mean ankle joint pressure at maximum volume was 142.2 ± 13.8 mm Hg (range, 122-166 mm Hg. Two of the nine samples showed evidence of fluid tracking into the synovial sheath of the flexor hallucis longus tendon. Conclusion: Maximal normal ankle joint volume was found to vary between 16-30 mL. This study ascertains the communication between the ankle joint and the flexor hallucis longus tendon sheath. Exceeding maximal ankle joint volume suggested by this study during therapeutic injections, arthrography, or arthroscopy could potentially damage the joint.

  8. Job Performance Tests for CH-53E Helicopter Mechanics. Volume 2: Administrative Duties and Job Knowledge Tests

    Science.gov (United States)

    1992-01-01

    SUBTmI.E 5 FU.NDING NUMBERS Job Performance Tests for CII-53E Helicopter Miechanacs - Volume I1: Admiutstrative Duties and Job Knowlede Tests C - N...performance measures to Marine Corps personnel managers . training instructors, and interested researchers who may find them useful. This work comprises...Corps personnel managers , training instructors, and interested researchers who may find them useful. 3. This work comprises two parts: volume I

  9. Space Biology and Medicine. Volume 4; Health, Performance, and Safety of Space Crews

    Science.gov (United States)

    Dietlein, Lawrence F. (Editor); Pestov, Igor D. (Editor)

    2004-01-01

    Volume IV is devoted to examining the medical and associated organizational measures used to maintain the health of space crews and to support their performance before, during, and after space flight. These measures, collectively known as the medical flight support system, are important contributors to the safety and success of space flight. The contributions of space hardware and the spacecraft environment to flight safety and mission success are covered in previous volumes of the Space Biology and Medicine series. In Volume IV, we address means of improving the reliability of people who are required to function in the unfamiliar environment of space flight as well as the importance of those who support the crew. Please note that the extensive collaboration between Russian and American teams for this volume of work resulted in a timeframe of publication longer than originally anticipated. Therefore, new research or insights may have emerged since the authors composed their chapters and references. This volume includes a list of authors' names and addresses should readers seek specifics on new information. At least three groups of factors act to perturb human physiological homeostasis during space flight. All have significant influence on health, psychological, and emotional status, tolerance, and work capacity. The first and most important of these factors is weightlessness, the most specific and radical change in the ambient environment; it causes a variety of functional and structural changes in human physiology. The second group of factors precludes the constraints associated with living in the sealed, confined environment of spacecraft. Although these factors are not unique to space flight, the limitations they entail in terms of an uncomfortable environment can diminish the well-being and performance of crewmembers in space. The third group of factors includes the occupational and social factors associated with the difficult, critical nature of the

  10. Analytical performance evaluation of a high-volume hematology laboratory utilizing sigma metrics as standard of excellence.

    Science.gov (United States)

    Shaikh, M S; Moiz, B

    2016-04-01

    Around two-thirds of important clinical decisions about the management of patients are based on laboratory test results. Clinical laboratories are required to adopt quality control (QC) measures to ensure provision of accurate and precise results. Six sigma is a statistical tool, which provides opportunity to assess performance at the highest level of excellence. The purpose of this study was to assess performance of our hematological parameters on sigma scale in order to identify gaps and hence areas of improvement in patient care. Twelve analytes included in the study were hemoglobin (Hb), hematocrit (Hct), red blood cell count (RBC), mean corpuscular volume (MCV), red cell distribution width (RDW), total leukocyte count (TLC) with percentages of neutrophils (Neutr%) and lymphocytes (Lymph %), platelet count (Plt), mean platelet volume (MPV), prothrombin time (PT), and fibrinogen (Fbg). Internal quality control data and external quality assurance survey results were utilized for the calculation of sigma metrics for each analyte. Acceptable sigma value of ≥3 was obtained for the majority of the analytes included in the analysis. MCV, Plt, and Fbg achieved value of performed poorly on both level 1 and 2 controls with sigma value of <3. Despite acceptable conventional QC tools, application of sigma metrics can identify analytical deficits and hence prospects for the improvement in clinical laboratories. © 2016 John Wiley & Sons Ltd.

  11. Improving motor reliability in nuclear power plants: Volume 1, Performance evaluation and maintenance practices

    International Nuclear Information System (INIS)

    Subudhi, M.; Gunther, W.E.; Taylor, J.H.; Sugarman, A.C.; Sheets, M.W.

    1987-11-01

    This report constitutes the first of the three volumes under this NUREG. The report presents recommendations for developing a cost-effective program for performance evaluation and maintenance of electric motors in nuclear power plants. These recommendations are based on current industry practices, available techniques for monitoring degradation in motor components, manufacturer's recommendations, operating experience, and results from two laboratory tests on aged motors. Two laboratory test reports on a small and a large motor are presented in separate volumes of this NUREG. These provide the basis for the various functional indicators recommended for maintenance programs in this report. The overall preventive maintenance program is separated into two broad areas of activity aimed at mitigating the potential effects of equipment aging: Performance Evaluation and Equipment Maintenance. The latter involves actually maintaining the condition of the equipment while the former involves those activities undertaken to monitor degradation due to aging. These monitoring methods are further categorized into periodic testing, surveillance testing, continuous monitoring and inspections. This study focuses on the methods and procedures for performing the above activities to maintain the motors operationally ready in a nuclear facility. This includes an assessment of various functional indicators to determine their suitability for trending to monitor motor component condition. The intrusiveness of test methods and the present state-of-the-art for using the test equipment in a plant environment are discussed. In conclusion, implementation of the information provided in this report, will improve motor reliability in nuclear power plants. The study indicates the kinds of tests to conduct, how and when to conduct them, and to which motors the tests should be applied. 44 refs., 12 figs., 13 tabs

  12. Performance of current intensive care unit ventilators during pressure and volume ventilation.

    Science.gov (United States)

    Marchese, Andrew D; Sulemanji, Demet; Chipman, Daniel; Villar, Jesús; Kacmarek, Robert M

    2011-07-01

    Intensive-care mechanical ventilators regularly enter the market, but the gas-delivery capabilities of many have never been assessed. We evaluated 6 intensive-care ventilators in the pressure support (PS), pressure assist/control (PA/C), and volume assist/control (VA/C) modes, with lung-model mechanics combinations of compliance and resistance of 60 mL/cm H(2)O and 10 cm H(2)O/L/s, 60 mL/cm H(2)O and 5 cm H(2)O/L/s, and 30 mL/cm H(2)O and 10 cm H(2)O/L/s, and inspiratory muscle effort of 5 and 10 cm H(2)O. PS and PA/C were set to 15 cm H(2)O, and PEEP to 5 and 15 cm H(2)O in all modes. During VA/C, tidal volume was set at 500 mL and inspiratory time was set at 0.8 second. Rise time and termination criteria were set at the manufacturers' defaults, and to an optimal level during PS and PA/C. There were marked differences in ventilator performance in all 3 modes. VA/C had the greatest difficulty meeting lung model demand and the greatest variability across all tested scenarios and ventilators. From high to low inspiratory muscle effort, pressure-to-trigger, time for pressure to return to baseline, and triggering pressure-time product decreased in all modes. With increasing resistance and decreasing compliance, tidal volume, pressure-to-trigger, time-to-trigger, time for pressure to return to baseline, time to 90% of peak pressure, and pressure-time product decreased. There were large differences between the default and optimal settings for all the variables in PS and PA/C. Performance was not affected by PEEP. Most of the tested ventilators performed at an acceptable level during the majority of evaluations, but some ventilators performed inadequately during specific settings. Bedside clinical evaluation is needed.

  13. Moderate association of anthropometry, but not training volume, with race performance in male ultraendurance cyclists.

    Science.gov (United States)

    Knechtle, Beat; Wirth, Andrea; Knechtle, Patrizia; Rosemann, Thomas

    2009-09-01

    In 28 male Caucasian nonprofessional ultracyclists, we investigated whether anthropometry or training volume had an influence on race speed in the 600 km at the Swiss Cycling Marathon 2007. Anthropometric parameters (age, body mass, body height, skinfold thicknesses) were determined before the race to calculate body mass index and percent body fat. In addition, participants, using a training diary, recorded their training volume in hours and kilometers in the 3 months before the race. The influence of anthropometry and training volume on speed in the race as the dependent variable was investigated in a multiple linear regression model. Anthropometry showed a moderate association with speed in the race (r2 = .178, p .05). We concluded that anthropometry had a greater influence on race performance than training volume in recreational ultraendurance cyclists.

  14. Satellite Power Systems (SPS) concept definition study, exhibit C. Volume 2, part 1: System engineering

    Science.gov (United States)

    Hanley, G. M.

    1979-01-01

    Volume 2, Part 1, of a seven volume report is presented. Part 1 encompasses Satellite Power Systems (SPS) systems engineering aspects and is divided into three sections. The first section presents descriptions of the various candidate concepts considered and conclusions and recommendations for a preferred concept. The second section presents a summary of results of the various trade studies and analysis conducted during the course of the study. The third section describes the Photovoltaic Satellite Based Satellite Power System (SPS) Point Design as it was defined through studies performed during the period January 1977 through March 1979.

  15. Provider volume and outcomes for oncological procedures.

    LENUS (Irish Health Repository)

    Killeen, S D

    2012-02-03

    BACKGROUND: Oncological procedures may have better outcomes if performed by high-volume providers. METHODS: A review of the English language literature incorporating searches of the Medline, Embase and Cochrane collaboration databases was performed. Studies were included if they involved a patient cohort from 1984 onwards, were community or population based, and assessed health outcome as a dependent variable and volume as an independent variable. The studies were also scored quantifiably to assess generalizability with respect to any observed volume-outcome relationship and analysed according to organ system; numbers needed to treat were estimated where possible. RESULTS: Sixty-eight relevant studies were identified and a total of 41 were included, of which 13 were based on clinical data. All showed either an inverse relationship, of variable magnitude, between provider volume and mortality, or no volume-outcome effect. All but two clinical reports revealed a statistically significant positive relationship between volume and outcome; none demonstrated the opposite. CONCLUSION: High-volume providers have a significantly better outcome for complex cancer surgery, specifically for pancreatectomy, oesphagectomy, gastrectomy and rectal resection.

  16. Restraint of appetite and reduced regional brain volumes in anorexia nervosa: a voxel-based morphometric study

    Directory of Open Access Journals (Sweden)

    Brooks Samantha J

    2011-11-01

    Full Text Available Abstract Background Previous Magnetic Resonance Imaging (MRI studies of people with anorexia nervosa (AN have shown differences in brain structure. This study aimed to provide preliminary extensions of this data by examining how different levels of appetitive restraint impact on brain volume. Methods Voxel based morphometry (VBM, corrected for total intracranial volume, age, BMI, years of education in 14 women with AN (8 RAN and 6 BPAN and 21 women (HC was performed. Correlations between brain volume and dietary restraint were done using Statistical Package for the Social Sciences (SPSS. Results Increased right dorsolateral prefrontal cortex (DLPFC and reduced right anterior insular cortex, bilateral parahippocampal gyrus, left fusiform gyrus, left cerebellum and right posterior cingulate volumes in AN compared to HC. RAN compared to BPAN had reduced left orbitofrontal cortex, right anterior insular cortex, bilateral parahippocampal gyrus and left cerebellum. Age negatively correlated with right DLPFC volume in HC but not in AN; dietary restraint and BMI predicted 57% of variance in right DLPFC volume in AN. Conclusions In AN, brain volume differences were found in appetitive, somatosensory and top-down control brain regions. Differences in regional GMV may be linked to levels of appetitive restraint, but whether they are state or trait is unclear. Nevertheless, these discrete brain volume differences provide candidate brain regions for further structural and functional study in people with eating disorders.

  17. The 13-year experience of performing pancreaticoduodenectomy in a mid-volume municipal hospital.

    Science.gov (United States)

    Kim, Hongbeom; Chung, Jung Kee; Ahn, Young Joon; Lee, Hae Won; Jung, In Mok

    2017-02-01

    Pancreaticoduodenectomy (PD) is a complex surgery associated with high morbidity, mortality, and cost. Municipal hospitals have their important role in the public health and welfare system. The purpose of this study was to identify the feasibility as well as the cost-effectiveness of performing PD in a mid-volume municipal hospital based on 13 years of experience with PD. From March 2003 to November 2015, 183 patients underwent PD at Seoul Metropolitan Government - Seoul National University Boramae Medical Center.. Retrospectively collected data were analyzed, with a particular focus on complications. Hospital costs were analyzed and compared with a national database, with patients divided into 2 groups on the basis of medical insurance status. The percentage of medical aid was significantly higher than the average in Korean hospitals. (19.1% vs. 5.8%, P = 0.002). Complications occurred in 88 patients (44.3%). Postoperative pancreatic fistula (POPF) occurred in 113 cases (61.7%), but the clinically relevant POPF was 24.6% (grade B: 23.5% and grade C: 1.1%). The median hospital stay after surgery was 20 days (range, 6-137 days). In-hospital mortality was 3.8% (n = 7), with pulmonary complications being the leading cause. During the study period, improvements were observed in POPF rate, operation time, and hospital stay. The mean total hospital cost was 13,819 United States dollar (USD) per patient, and the mean reimbursement from the National Health Insurance Service (NHIS) to health care providers was 10,341 USD (74.8%). The patient copayment portion of the NHIS payment was 5%. Performing PD in a mid-volume municipal hospital is feasible, with comparable results and cost-effectiveness.

  18. Feasibility study on application of volume acid fracturing technology to tight gas carbonate reservoir development

    Directory of Open Access Journals (Sweden)

    Nianyin Li

    2015-09-01

    Full Text Available How to effectively develop tight-gas carbonate reservoir and achieve high recovery is always a problem for the oil and gas industry. To solve this problem, domestic petroleum engineers use the combination of the successful experiences of North American shale gas pools development by stimulated reservoir volume (SRV fracturing with the research achievements of Chinese tight gas development by acid fracturing to propose volume acid fracturing technology for fractured tight-gas carbonate reservoir, which has achieved a good stimulation effect in the pilot tests. To determine what reservoir conditions are suitable to carry out volume acid fracturing, this paper firstly introduces volume acid fracturing technology by giving the stimulation mechanism and technical ideas, and initially analyzes the feasibility by the comparison of reservoir characteristics of shale gas with tight-gas carbonate. Then, this paper analyzes the validity and limitation of the volume acid fracturing technology via the analyses of control conditions for volume acid fracturing in reservoir fracturing performance, natural fracture, horizontal principal stress difference, orientation of in-situ stress and natural fracture, and gives the solution for the limitation. The study results show that the volume acid fracturing process can be used to greatly improve the flow environment of tight-gas carbonate reservoir and increase production; the incremental or stimulation response is closely related with reservoir fracturing performance, the degree of development of natural fracture, the small intersection angle between hydraulic fracture and natural fracture, the large horizontal principal stress difference is easy to form a narrow fracture zone, and it is disadvantageous to create fracture network, but the degradable fiber diversion technology may largely weaken the disadvantage. The practices indicate that the application of volume acid fracturing process to the tight-gas carbonate

  19. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear

  20. Effective orbital volume and eyeball position: an MRI study.

    Science.gov (United States)

    Detorakis, Efstathios T; Drakonaki, Eleni; Papadaki, Efrosini; Pallikaris, Ioannis G; Tsilimbaris, Miltiadis K

    2010-10-01

    Previous studies have examined factors affecting the position of the eyeball to the orbit. This study examined the role of effective orbital volume (EOV), defined as the difference between orbital and eyeball volume, as a determinant of eyeball position, using MRI scans. Forty-six patients were recruited from the Department of Ophthalmology of the University Hospital of Heraklion, Crete Greece. Patients with a history of orbital disease were excluded. Distances between eyeball poles and orbital landmarks were measured in T1 weighted transverse, sagittal and coronal orbital images. The protrusion of the eyeball in the sagittal and transverse planes was recorded. The volume of the eyeball and bony orbit, the EOV, the volume of the extraocular muscles as well as clinical information (age, gender, Hertel exophthalmometry) were also recorded. EOV was significantly associated with orbital volume but not with eyeball volume. EOV was also significantly associated with transverse and sagittal globe protrusions. Females displayed significantly lower orbital and eyeball volumes as well as EOV than males but higher transverse globe protrusion than males. Variations in EOV are associated with orbital volume rather than with eyeball volume. EOV is associated with globe protrusion and may be taken into account in the planning of various procedures, including orbital decompression, treatment of enophthalmos or the size of orbital implants following enucleation.

  1. Increased gray matter volume of left pars opercularis in male orchestral musicians correlate positively with years of musical performance.

    Science.gov (United States)

    Abdul-Kareem, Ihssan A; Stancak, Andrej; Parkes, Laura M; Sluming, Vanessa

    2011-01-01

    To compare manual volumetry of gray matter (GM) / white matter (WM) of Broca's area subparts: pars opercularis (POP) and pars triangularis (PTR) in both hemispheres between musicians and nonmusician, as it has been shown that these regions are crucial for musical abilities. A previous voxel-based morphometric (VBM) study conducted in our laboratory reported increased GM density in Broca's area of left hemisphere in male orchestral musicians. Functional segregation of POP/PTR justified separate volumetric analysis of these parts. We used the same cohort for the VBM study. Manual morphometry (stereology) was used to compare volumes between 26/26 right-handed orchestral musicians/nonmusicians. As expected, musicians showed significantly increased GM volume in the Broca's area, specifically in the left POP. No significant results were detected in right POP, left/right PTR GM volumes, and WM volumes for all regions. Results were positively correlated with years of musical performance (r = 0.7, P = 0.0001). This result corroborates the VBM study and is in line with the hypothesis of critical involvement of POP in hearing-action integration being an integral component of frontoparietotemporal mirror neuron network. We hypothesize that increased size of musicians' left POP represent use-dependent structural adaptation in response to intensive audiomotor skill acquisition. Copyright © 2010 Wiley-Liss, Inc.

  2. The estimated volume of the fibroid uterus: a comparison of ultrasound and bimanual examination versus volume at MRI or hysterectomy

    NARCIS (Netherlands)

    Stoelinga, Barbara; Huirne, Judith; Heymans, Martijn W.; Reekers, Jim A.; Ankum, Willem M.; Hehenkamp, Wouter J. K.

    2015-01-01

    The volume of a fibroid uterus before performing hysterectomy is typically estimated through bimanual examination and confirmed by ultrasonography. This study compares estimated volumes by bimanual examination and ultrasound examination with MRI and actual volumes obtained from histopathology, as

  3. Volumetrically-Derived Global Navigation Satellite System Performance Assessment from the Earths Surface through the Terrestrial Service Volume and the Space Service Volume

    Science.gov (United States)

    Welch, Bryan W.

    2016-01-01

    NASA is participating in the International Committee on Global Navigation Satellite Systems (GNSS) (ICG)'s efforts towards demonstrating the benefits to the space user from the Earth's surface through the Terrestrial Service Volume (TSV) to the edge of the Space Service Volume (SSV), when a multi-GNSS solution space approach is utilized. The ICG Working Group: Enhancement of GNSS Performance, New Services and Capabilities has started a three phase analysis initiative as an outcome of recommendations at the ICG-10 meeting, in preparation for the ICG-11 meeting. The first phase of that increasing complexity and fidelity analysis initiative was recently expanded to compare nadir-facing and zenith-facing user hemispherical antenna coverage with omnidirectional antenna coverage at different distances of 8,000 km altitude and 36,000 km altitude. This report summarizes the performance using these antenna coverage techniques at distances ranging from 100 km altitude to 36,000 km to be all encompassing, as well as the volumetrically-derived system availability metrics.

  4. Phase 1 study of metallic cask systems for spent fuel management from reactor to repository. Volume I. Phase 1 study summary

    International Nuclear Information System (INIS)

    1986-02-01

    It was proposed to perform a systems evaluation of metallic cask systems in order to define and examine the use of various metallic cask concepts or combination of concepts for the overall inventory management of spent fuel starting with its discharge from reactors to its emplacement in geologic repositories. This systems evaluation occurs in three phases. This three phase systems evaluation leads to a definition and recommendation of a sound and practical metallic cask system to accomplish efficient and effective management of spent fuel in the back end of the nuclear fuel cycle. Phase 1 Study objectives: establish system-wide functional criteria and assumptions; perform the systems engineering needed to define the metallic cask concepts and their feasibility; perform a screening evaluation of the technical and economic merits of the concepts; and recommend those to be included for a more detailed systems evaluation in Phase 2. Phase 2 Study objectives: refine the system-wide functional criteria and assumptions; perform the design engineering needed to enhance the validity and workability of those concepts recommended in Phase 1; and perform a more detailed systems evaluation. Phase 3 Study objectives: conclude the systems evaluation and develop an implementation plan. Volume I presents an overview of the detailed systems evaluation presented in Volume II

  5. Volume-constrained optimization of magnetorheological and electrorheological valves and dampers

    Science.gov (United States)

    Rosenfeld, Nicholas C.; Wereley, Norman M.

    2004-12-01

    This paper presents a case study of magnetorheological (MR) and electrorheological (ER) valve design within a constrained cylindrical volume. The primary purpose of this study is to establish general design guidelines for volume-constrained MR valves. Additionally, this study compares the performance of volume-constrained MR valves against similarly constrained ER valves. Starting from basic design guidelines for an MR valve, a method for constructing candidate volume-constrained valve geometries is presented. A magnetic FEM program is then used to evaluate the magnetic properties of the candidate valves. An optimized MR valve is chosen by evaluating non-dimensional parameters describing the candidate valves' damping performance. A derivation of the non-dimensional damping coefficient for valves with both active and passive volumes is presented to allow comparison of valves with differing proportions of active and passive volumes. The performance of the optimized MR valve is then compared to that of a geometrically similar ER valve using both analytical and numerical techniques. An analytical equation relating the damping performances of geometrically similar MR and ER valves in as a function of fluid yield stresses and relative active fluid volume, and numerical calculations are provided to calculate each valve's damping performance and to validate the analytical calculations.

  6. Brain volumes and neuropsychological performance are related to current smoking and alcoholism history

    Directory of Open Access Journals (Sweden)

    Luhar RB

    2013-11-01

    Full Text Available Riya B Luhar,1,2 Kayle S Sawyer,1,2 Zoe Gravitz,1,2 Susan Mosher Ruiz,1,2 Marlene Oscar-Berman1–3 1US Department of Veterans Affairs, Boston Healthcare System, 2Boston University School of Medicine, 3Athinoula A Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, USA Background: Dual dependence on alcohol and nicotine is common, with many reports suggesting that more than 80% of alcoholics also smoke cigarettes. Even after cessation of alcohol consumption, many recovering alcoholics continue to smoke. In this exploratory study, we examined how current smoking and a history of alcoholism interacted in relation to brain volumes and neuropsychological performance. Methods: Participants were 14 abstinent long-term alcoholics (seven current smokers and seven nonsmokers, and 13 nonalcoholics (six current smokers and seven nonsmokers. The groups were equivalent in age, gender, education, and intelligence quotient. Two multiecho magnetization-prepared rapid acquisition with gradient echo (MP-RAGE scans were collected for all participants using a 3T magnetic resonance imaging scanner with a 32 channel head coil. Brain volumes for each gray and white matter region of interest were derived using FreeSurfer. Participants completed a battery of neuropsychological tests measuring intelligence quotient, memory, executive functions, personality variables, and affect. Results: Compared to nonsmoking nonalcoholics, alcoholics who smoke (the comorbid group had volumetric abnormalities in: pre- and para-central frontal cortical areas and rostral middle frontal white matter; parahippocampal and temporal pole regions; the amygdala; the pallidum; the ventral diencephalic region; and the lateral ventricle. The comorbid group performed worse than nonsmoking nonalcoholics on tests of executive functioning and on visually-based memory tests. History of alcoholism was associated with higher neuroticism scores among smokers, and current

  7. Volume perfusion CT imaging of cerebral vasospasm: diagnostic performance of different perfusion maps

    Energy Technology Data Exchange (ETDEWEB)

    Othman, Ahmed E. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Radiology, Tuebingen (Germany); Afat, Saif; Nikoubashman, Omid; Mueller, Marguerite; Wiesmann, Martin; Brockmann, Carolin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); Schubert, Gerrit Alexander [RWTH Aachen University, Department of Neurosurgery, Aachen (Germany); Bier, Georg [Eberhard Karls University Tuebingen, University Hospital Tuebingen, Department for Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Brockmann, Marc A. [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, Aachen (Germany); University Hospital Mainz, Department of Neuroradiology, Mainz (Germany)

    2016-08-15

    In this study, we aimed to evaluate the diagnostic performance of different volume perfusion CT (VPCT) maps regarding the detection of cerebral vasospasm compared to angiographic findings. Forty-one datasets of 26 patients (57.5 ± 10.8 years, 18 F) with subarachnoid hemorrhage and suspected cerebral vasospasm, who underwent VPCT and angiography within 6 h, were included. Two neuroradiologists independently evaluated the presence and severity of vasospasm on perfusion maps on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting <50 %, 2 - vasospasm affecting >50 % of vascular territory). A third neuroradiologist independently assessed angiography for the presence and severity of vasospasm on a 3-point Likert scale (0 - no vasospasm, 1 - vasospasm affecting < 50 %, 2 - vasospasm affecting > 50 % of vessel diameter). Perfusion maps of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and time to drain (TTD) were evaluated regarding diagnostic accuracy for cerebral vasospasm with angiography as reference standard. Correlation analysis of vasospasm severity on perfusion maps and angiographic images was performed. Furthermore, inter-reader agreement was assessed regarding findings on perfusion maps. Diagnostic accuracy for TTD and MTT was significantly higher than for all other perfusion maps (TTD, AUC = 0.832; MTT, AUC = 0.791; p < 0.001). TTD revealed higher sensitivity than MTT (p = 0.007). The severity of vasospasm on TTD maps showed significantly higher correlation levels with angiography than all other perfusion maps (p ≤ 0.048). Inter-reader agreement was (almost) perfect for all perfusion maps (kappa ≥ 0.927). The results of this study indicate that TTD maps have the highest sensitivity for the detection of cerebral vasospasm and highest correlation with angiography regarding the severity of vasospasm. (orig.)

  8. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters.

    Science.gov (United States)

    Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B

    2013-11-01

    Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and

  9. Performance evaluation of the technical capabilities of DOE sites for disposal of mixed low-level waste. Volume 1: Executive summary

    International Nuclear Information System (INIS)

    1996-03-01

    A team of analysts designed and conducted a performance evaluation (PE) to estimate the technical capabilities of fifteen Department of Energy sites for disposal of mixed low-level waste (i.e., waste that contains both low-level radioactive materials and hazardous constituents). Volume 1 summarizes the process for selecting the fifteen sites, the methodology used in the evaluation, and the conclusions derived from the evaluation. Volume 1 is an executive summary both of the PE methodology and of the results obtained from the PEs. While this volume briefly reviews the scope and method of analyses, its main objective is to emphasize the important insights and conclusions derived from the conduct of the PEs. Volume 2 provides details about the site-selection process, the performance-evaluation methodology, and the overall results of the analysis. Volume 3 contains detailed evaluations of the fifteen sites and discussions of the results for each site

  10. Tidal volume and mortality in mechanically ventilated children: a systematic review and meta-analysis of observational studies*.

    Science.gov (United States)

    de Jager, Pauline; Burgerhof, Johannes G M; van Heerde, Marc; Albers, Marcel J I J; Markhorst, Dick G; Kneyber, Martin C J

    2014-12-01

    To determine whether tidal volume is associated with mortality in critically ill, mechanically ventilated children. MEDLINE, EMBASE, and CINAHL databases from inception until July 2013 and bibliographies of included studies without language restrictions. Randomized clinical trials and observational studies reporting mortality in mechanically ventilated PICU patients. Two authors independently selected studies and extracted data on study methodology, quality, and patient outcomes. Meta-analyses were performed using the Mantel-Haenszel random-effects model. Heterogeneity was quantified using I. Study quality was assessed using the Newcastle-Ottawa Score for cohort studies. Out of 142 citations, seven studies met the inclusion criteria, and additional two articles were identified from references of the found articles. One was excluded. These eight studies included 1,756 patients. Mortality rates ranged from 13% to 42%. There was no association between tidal volume and mortality when tidal volume was dichotomized at 7, 8, 10, or 12 mL/kg. Comparing patients ventilated with tidal volume less than 7 mL/kg and greater than 10 mL/kg or greater than 12 mL/kg and tidal volume less than 8 mL/kg and greater than 10 mL/kg or greater than 12 mL/kg also showed no association between tidal volume and mortality. Limiting the analysis to patients with acute lung injury/acute respiratory distress syndrome did not change these results. Heterogeneity was observed in all pooled analyses. A relationship between tidal volume and mortality in mechanically ventilated children could not be identified, irrespective of the severity of disease. The significant heterogeneity observed in the pooled analyses necessitates future studies in well-defined patient populations to understand the effects of tidal volume on patient outcome.

  11. Metabolic volume performs better than SUVmax in the detection of left ventricular assist device driveline infection

    Energy Technology Data Exchange (ETDEWEB)

    Avramovic, Nemanja; Weckesser, Matthias; Milankovic, Danka; Vrachimis, Alexis; Wenning, Christian [University Hospital Muenster, Department of Nuclear Medicine, Muenster (Germany); Dell' Aquila, Angelo Maria; Sindermann, Juergen R. [University Hospital Muenster, Department of Cardiac Surgery, Muenster (Germany)

    2017-10-15

    A continuous-flow left ventricular assist device (LVAD) is a new and highly promising therapy in supporting end-stage heart failure patients, either bridging them to heart transplantation or as a destination therapy. Infection is one of the major complications associated with LVAD implants. {sup 18}F-FDG PET/CT has already been shown to be useful in the detection of LVAD infection. The goal of this study was to compare the diagnostic accuracy of different PET analysis techniques (visual grading versus SUVmax and metabolic volume). We retrospectively analyzed 48 patients with implanted LVAD who underwent an {sup 18}F-FDG PET/CT that were either suspected to have a driveline or device infection or inflammation of unknown origin. PET/CT was analyzed qualitatively (visual grading) and quantitatively (SUVmax and metabolic volume) and matched to the final clinical diagnosis concerning driveline infection. The final diagnosis (standard of reference) was made at the end of clinically recorded follow-up or transplantation and included microbiological cultures of the driveline exit site and/or surgical samples, and clinical signs of infection despite negative cultures as well as recurrence of symptoms. Sensitivity, specificity, positive and negative predictive value were 87.5%, 79%, 81% and 86% for visual score, 87.5%, 87.5%, 87.5% and 87.5% for SUVmax and 96%, 87.5%, 88.5%, 95.5% for metabolic volume, respectively. ROC analysis revealed an AUC of.929 for SUVmax and.969 for metabolic volume. Both SUVmax and metabolic volume had a high detection rate of patients with driveline infection (21/24 = 91.5% true positive vs. 23/26 = 88.5% true positive, respectively). However, metabolic volume detected more patients without any infection correctly (1/22 = 4.5% false negative vs. 3/24 = 12.5% false negative). {sup 18}F-FDG PET/CT is a valuable tool for the diagnosis of LVAD driveline infection with high diagnostic accuracy. Particularly the use of the metabolic volume yields very

  12. Description and performance of a prototype PET system for small volume imaging

    International Nuclear Information System (INIS)

    McKee, B.T.A.; Hogan, M.J.; Queen's Univ., Kingston, Ontario; Dinsdale, H.B.; Howse, D.C.N.; Kulick, J.; Mak, H.B.; Stewart, H.B.

    1988-01-01

    A prototype positron emission tomography (PET) system has been designed for high-resolution imaging of small volumes. The detectors use Pb converter stacks and multiwire proportional counters (MWPC); the data acquisition components and image reconstruction methods are also described briefly. The performance of the system is discussed in terms of sensitivity, count rate capability, spatial resolution, and scattered background. Three examples of metabolic or transport imaging demonstrate the capabilities and limitations of the system. These are blood flow to bone, cerebral glucose uptake, and nutrient translocation in plants. The performance of the prototype has been sufficiently promising that an improved system is under development. (orig.)

  13. Cerebral gray matter volume losses in essential tremor: A case-control study using high resolution tissue probability maps.

    Science.gov (United States)

    Cameron, Eric; Dyke, Jonathan P; Hernandez, Nora; Louis, Elan D; Dydak, Ulrike

    2018-03-10

    Essential tremor (ET) is increasingly recognized as a multi-dimensional disorder with both motor and non-motor features. For this reason, imaging studies are more broadly examining regions outside the cerebellar motor loop. Reliable detection of cerebral gray matter (GM) atrophy requires optimized processing, adapted to high-resolution magnetic resonance imaging (MRI). We investigated cerebral GM volume loss in ET cases using automated segmentation of MRI T1-weighted images. MRI was acquired on 47 ET cases and 36 controls. Automated segmentation and voxel-wise comparisons of volume were performed using Statistical Parametric Mapping (SPM) software. To improve upon standard protocols, the high-resolution International Consortium for Brain Mapping (ICBM) 2009a atlas and tissue probability maps were used to process each subject image. Group comparisons were performed: all ET vs. Controls, ET with head tremor (ETH) vs. Controls, and severe ET vs. An analysis of variance (ANOVA) was performed between ET with and without head tremor and controls. Age, sex, and Montreal Cognitive Assessment (MoCA) score were regressed out from each comparison. We were able to consistently identify regions of cerebral GM volume loss in ET and in ET subgroups in the posterior insula, superior temporal gyri, cingulate cortex, inferior frontal gyri and other occipital and parietal regions. There were no significant increases in GM volume in ET in any comparisons with controls. This study, which uses improved methodologies, provides evidence that GM volume loss in ET is present beyond the cerebellum, and in fact, is widespread throughout the cerebrum as well. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Performance evaluation of the technical capabilities of DOE sites for disposal of mixed low-level waste: Volume 3, Site evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Waters, R.D.; Gruebel, M.M. [eds.

    1996-03-01

    A team of analysts designed and conducted a performance evaluation to estimate the technical capabilities of fifteen Department of Energy sites for disposal of mixed low-level waste (i.e., waste that contains both low-level radioactive materials and hazardous constituents). Volume 1 summarizes the process for selecting the fifteen sites, the methodology used in the evaluation, and the conclusions derived from the evaluation. Volume 2 provides details about the site-selection process, the performance-evaluation methodology, and the overall results of the analysis. Volume 3 contains detailed evaluations of the fifteen sites and discussion of the results for each site.

  15. Performance evaluation of the technical capabilities of DOE sites for disposal of mixed low-level waste: Volume 3, Site evaluations

    International Nuclear Information System (INIS)

    Waters, R.D.; Gruebel, M.M.

    1996-03-01

    A team of analysts designed and conducted a performance evaluation to estimate the technical capabilities of fifteen Department of Energy sites for disposal of mixed low-level waste (i.e., waste that contains both low-level radioactive materials and hazardous constituents). Volume 1 summarizes the process for selecting the fifteen sites, the methodology used in the evaluation, and the conclusions derived from the evaluation. Volume 2 provides details about the site-selection process, the performance-evaluation methodology, and the overall results of the analysis. Volume 3 contains detailed evaluations of the fifteen sites and discussion of the results for each site

  16. Maintenance Personnel Performance Simulation (MAPPS) model: description of model content, structure, and sensitivity testing. Volume 2

    International Nuclear Information System (INIS)

    Siegel, A.I.; Bartter, W.D.; Wolf, J.J.; Knee, H.E.

    1984-12-01

    This volume of NUREG/CR-3626 presents details of the content, structure, and sensitivity testing of the Maintenance Personnel Performance Simulation (MAPPS) model that was described in summary in volume one of this report. The MAPPS model is a generalized stochastic computer simulation model developed to simulate the performance of maintenance personnel in nuclear power plants. The MAPPS model considers workplace, maintenance technician, motivation, human factors, and task oriented variables to yield predictive information about the effects of these variables on successful maintenance task performance. All major model variables are discussed in detail and their implementation and interactive effects are outlined. The model was examined for disqualifying defects from a number of viewpoints, including sensitivity testing. This examination led to the identification of some minor recalibration efforts which were carried out. These positive results indicate that MAPPS is ready for initial and controlled applications which are in conformity with its purposes

  17. Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992. Volume 5, Uncertainty and sensitivity analyses of gas and brine migration for undisturbed performance

    Energy Technology Data Exchange (ETDEWEB)

    1993-08-01

    Before disposing of transuranic radioactive waste in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments (PAs) of the WIPP for the DOE to provide interim guidance while preparing for a final compliance evaluation. This volume of the 1992 PA contains results of uncertainty and sensitivity analyses with respect to migration of gas and brine from the undisturbed repository. Additional information about the 1992 PA is provided in other volumes. Volume 1 contains an overview of WIPP PA and results of a preliminary comparison with 40 CFR 191, Subpart B. Volume 2 describes the technical basis for the performance assessment, including descriptions of the linked computational models used in the Monte Carlo analyses. Volume 3 contains the reference data base and values for input parameters used in consequence and probability modeling. Volume 4 contains uncertainty and sensitivity analyses with respect to the EPA`s Environmental Standards for the Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B). Finally, guidance derived from the entire 1992 PA is presented in Volume 6. Results of the 1992 uncertainty and sensitivity analyses indicate that, conditional on the modeling assumptions and the assigned parameter-value distributions, the most important parameters for which uncertainty has the potential to affect gas and brine migration from the undisturbed repository are: initial liquid saturation in the waste, anhydrite permeability, biodegradation-reaction stoichiometry, gas-generation rates for both corrosion and biodegradation under inundated conditions, and the permeability of the long-term shaft seal.

  18. The Impact of the Hospital Volume on the Performance of Residents on the General Medicine In-Training Examination: A Multicenter Study in Japan.

    Science.gov (United States)

    Mizuno, Atsushi; Tsugawa, Yusuke; Shimizu, Taro; Nishizaki, Yuji; Okubo, Tomoya; Tanoue, Yusuke; Konishi, Ryota; Shiojiri, Toshiaki; Tokuda, Yasuharu

    2016-01-01

    Objective Although several studies have been conducted worldwide on factors that might improve residents' knowledge, the relationship between the hospital volume and the internal medicine residents' knowledge has not been fully understood. We conducted a cross-sectional study to compare the relationships of the hospital volume and hospital resources with the residents' knowledge assessed by the In-training Examination. Methods We conducted a retrospective survey and a clinical knowledge evaluation of postgraduate year 1 and 2 (PGY-1 and -2) resident physicians in Japan by using the General Medicine In-training Examination (GM-ITE) in 2014. We compared the ITE score and the hospital volume. Results A total of 2,015 participants (70.6% men; age, 27.3±2.9 years old) from 208 hospitals were retrospectively analyzed. Generalized estimating equations were used, and the results revealed that an increasing number of hospitalizations, decreasing staff number, decreasing age and PGY-2 were significantly associated with higher GM-ITE scores. Conclusion The hospital volume, such as the number of hospitalizations, is thus considered to have a positive impact on the GM-ITE scores.

  19. Effects of plyometric training volume and training surface on explosive strength.

    Science.gov (United States)

    Ramírez-Campillo, Rodrigo; Andrade, David C; Izquierdo, Mikel

    2013-10-01

    The purpose of this study is to examine the effects of different volume and training surfaces during a short-term plyometric training program on neuromuscular performance. Twenty-nine subjects were randomly assigned to 4 groups: control group (CG, n = 5), moderate volume group (MVG, n = 9, 780 jumps), moderate volume hard surface group (MVGHS, n = 8, 780 jumps), and high volume group (HVG, n = 7, 1,560 jumps). A series of tests were performed by the subjects before and after 7 weeks of plyometric training. These tests were measurement of maximum strength (5 maximum repetitions [5RMs]), drop jumps (DJs) of varying heights (20, 40, and 60 cm), squat and countermovement jumps (SJ and CMJ, respectively), timed 20-m sprint, agility, body weight, and height. The results of the present study suggest that high training volume leads to a significant increase in explosive performance that requires fast stretch-shortening cycle (SSC) actions (such as DJ and sprint) in comparison to what is observed after a moderate training volume regimen. Second, when plyometric training is performed on a hard training surface (high-impact reaction force), a moderate training volume induces optimal stimulus to increase explosive performance requiring fast SSC actions (e.g., DJ), maximal dynamic strength enhancement, and higher training efficiency. Thus, a finding of interest in the study was that after 7 weeks of plyometric training, performance enhancement in maximal strength and in actions requiring fast SSC (such as DJ and sprint) were dependent on the volume of training and the surface on which it was performed. This must be taken into account when using plyometric training on different surfaces.

  20. A Study of Job Demands and Curriculum Development in Agricultural Training Related to the Muskegon County Wastewater Management System. Final Report. Volume III. Student Terminal Performance Objectives and Instructional Modules.

    Science.gov (United States)

    Fisher, Harold S.; And Others

    This is the third volume of a four-volume report of a research project designed to (1) identify job needs for agricultural occupations which will result from the Muskegon County Wastewater Management System and perform a task analysis on each occupation, (2) develop instructional modules and determine their place in either high school or 2-year…

  1. Study of volume fractions on biphasic stratified regime using gamma ray

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, William L.; Brandão, Luis E.B., E-mail: william.otero@hotmail.com, E-mail: brandao@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    In the oil industries, interconnected pipelines are used to carry large quantities of petroleum and its byproducts. This modal has an advantage because they are more economical, eliminate a need for stocks and, in addition, great safety in operation minimizing a possibility of loss or theft when transported another way. In many cases, especially in the petrochemical industry, the same pipeline is used to carry more than one type of product. They are called poliduct. In the operation of a poliduct there is a sequence of products to be transported and during the exchange of the product, there are still fractions of the previous product and this generates contamination. It is therefore important to identify precisely this region in order to reduce the costs of reprocessing and treatment of discarded products. In this way, this work presents a methodology to evaluate the sensitivity of the gamma densitometry technique in a study of the calculation of volume fractions in biphasic systems, submitted to the stratified flow regime. Using computational simulations using the Monte Carlo Method with the MCNPX code measurement geometry was proposed that presented a higher sensitivity for the calculation of volume fractions. The relevant technical data to perform a simulation of the scintillator detectors were based on information obtained from the gammagraphy technique. The study had a theoretical validation through analytical equations, and the results show that it is possible to identify volume fractions equivalent to 3%. (author)

  2. Study of volume fractions on biphasic stratified regime using gamma ray

    International Nuclear Information System (INIS)

    Salgado, William L.; Brandão, Luis E.B.

    2017-01-01

    In the oil industries, interconnected pipelines are used to carry large quantities of petroleum and its byproducts. This modal has an advantage because they are more economical, eliminate a need for stocks and, in addition, great safety in operation minimizing a possibility of loss or theft when transported another way. In many cases, especially in the petrochemical industry, the same pipeline is used to carry more than one type of product. They are called poliduct. In the operation of a poliduct there is a sequence of products to be transported and during the exchange of the product, there are still fractions of the previous product and this generates contamination. It is therefore important to identify precisely this region in order to reduce the costs of reprocessing and treatment of discarded products. In this way, this work presents a methodology to evaluate the sensitivity of the gamma densitometry technique in a study of the calculation of volume fractions in biphasic systems, submitted to the stratified flow regime. Using computational simulations using the Monte Carlo Method with the MCNPX code measurement geometry was proposed that presented a higher sensitivity for the calculation of volume fractions. The relevant technical data to perform a simulation of the scintillator detectors were based on information obtained from the gammagraphy technique. The study had a theoretical validation through analytical equations, and the results show that it is possible to identify volume fractions equivalent to 3%. (author)

  3. Feasibility of developing a portable driver performance data acquisition system for human factors research: Technical tasks. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Carter, R.J.; Barickman, F.S.; Spelt, P.F.; Schmoyer, R.L.; Kirkpatrick, J.R.

    1998-01-01

    A two-phase, multi-year research program entitled ``development of a portable driver performance data acquisition system for human factors research`` was recently completed. The primary objective of the project was to develop a portable data acquisition system for crash avoidance research (DASCAR) that will allow drive performance data to be collected using a large variety of vehicle types and that would be capable of being installed on a given vehicle type within a relatively short-time frame. During phase 1 a feasibility study for designing and fabricating DASCAR was conducted. In phase 2 of the research DASCAR was actually developed and validated. This technical memorandum documents the results from the feasibility study. It is subdivided into three volumes. Volume one (this report) addresses the last five items in the phase 1 research and the first issue in the second phase of the project. Volumes two and three present the related appendices, and the design specifications developed for DASCAR respectively. The six tasks were oriented toward: identifying parameters and measures; identifying analysis tools and methods; identifying measurement techniques and state-of-the-art hardware and software; developing design requirements and specifications; determining the cost of one or more copies of the proposed data acquisition system; and designing a development plan and constructing DASCAR. This report also covers: the background to the program; the requirements for the project; micro camera testing; heat load calculations for the DASCAR instrumentation package in automobile trunks; phase 2 of the research; the DASCAR hardware and software delivered to the National Highway Traffic Safety Administration; and crash avoidance problems that can be addressed by DASCAR.

  4. A cross-sectional study of hormone treatment and hippocampal volume in postmenopausal women: evidence for a limited window of opportunity.

    Science.gov (United States)

    Erickson, Kirk I; Voss, Michelle W; Prakash, Ruchika S; Chaddock, Laura; Kramer, Arthur F

    2010-01-01

    The influence of hormone treatment on brain and cognition in postmenopausal women has been a controversial topic. Contradictory patterns of results have prompted speculation that a critical period, or limited window of opportunity, exists for hormone treatment to protect against neurocognitive. In this cross-sectional study of 102 postmenopausal women, we examined whether hippocampal, amygdala, or caudate nucleus volumes and spatial memory performance were related to the interval between menopause and the initiation of hormone treatment. Consistent with a critical period hypothesis, we found that shorter intervals between menopause and the initiation of hormone treatment were associated with larger hippocampal volumes compared with longer intervals between menopause and treatment initiation. Initiation of hormone treatment at the time of menopause was also associated with larger hippocampal volumes when compared with peers who had never used hormone treatment. Furthermore, these effects were independent from potentially confounding factors such as age, years of education, the duration of hormone treatment, current or past use of hormone therapy, the type of therapy, and age at menopause. Larger hippocampal volumes in women who initiated hormone treatment at the time of menopause failed to translate to improved spatial memory performance. There was no relationship between timing of hormone initiation, spatial memory performance, and amygdala or caudate nucleus volume. Our results provide support for a limited window of opportunity for hormone treatment to influence hippocampal volume, yet the degree to which these effects translate to improved memory performance is uncertain. Copyright 2009 APA, all rights reserved.

  5. SU-F-T-40: Can CBCT Images Be Used for Volume Studies of Prostate Seed Implants for Boost Treatment?

    Energy Technology Data Exchange (ETDEWEB)

    Xu, H; Lee, S; Diwanji, T; Amin, P; Krudys, K; Guerrero, M [University of Maryland School of Medicine, Baltimore, MD (United States)

    2016-06-15

    Purpose: In our clinic, the planning CT is used for definitive and boost low-dose-rate (LDR) brachytherapy treatments to determine the ultrasound volume in the operating room (OR) at the time of the implant. While the CT overestimation of OR volume is known, a larger estimation discrepancy has been observed for boost treatments. A possible reason is the prostate size reduction during EBRT for boost patients. Since cone-beam CT (CBCT) is often used as routine imaging guidance of EBRT, this prostate volume change may be captured. This study investigates if CBCT taken during EBRT includes the volume change information and therefore beats CT in estimating the prostate OR volumes. Methods: 9 prostate patients treated with EBRT (45Gy in 1.8Gy per fractions to the whole pelvis) and I-125 seed implants (108Gy) were involved in this study. During EBRT, CBCT image guidance was performed on a weekly basis. For each patient, the prostate volumes on the first and the last available CBCT images were manually contoured by a physician. These volumes were then compared to each other and with the contoured volumes from the planning CT and from the ultrasound images in the OR. Results: The first and the last CBCT images did not show significant prostate volume change. Their average +/− standard deviation of prostate volumes were 24.4cc+/−14.6cc and 29.9cc+/−16.1cc, respectively (T-test p=0.68). The ratio of the OR volume to the last CBCT (0.71+/−0.21) was not significantly different from the ratio of OR volumes to the planning CT (0.61+/−0.13) (p=0.25). Conclusion: In this study, CBCT does not show significant prostate volume changes during EBRT. CBCT and CT volumes are quite consistent and no improvement of volume estimation using CBCT is observed. The advantage of CBCT as a replacement of CT for volume study of boost LDR brachytherapy is limited.

  6. Positron annihilation study on free volume of amino acid modified, starch-grafted acrylamide copolymer

    International Nuclear Information System (INIS)

    Mahmoud, K.R.; Al-Sigeny, S.; Sharshar, T.; El-Hamshary, H.

    2006-01-01

    Free volume measurements using positron annihilation lifetime spectroscopy was performed for uncrosslinked and crosslinked starch-grafted polyacrylamide, and their modified amino acid samples including some of their iron(III) complexes. The measurements were performed at room temperature. The analysis of lifetime spectra yielded mostly three lifetime components. It was observed that the values of the short lifetime component τ 1 are slightly higher than the lifetime associated with the self-decay of para-positronium atoms in polymers. The free volume was probed using ortho-positronium pick-off annihilation lifetime parameters. The mean free volume has also been calculated from the lifetime data. The avrage value of this parameter of the crosslinked polymer were found to be higher than those of the uncrosslinked polymer

  7. Volume and density of microglomeruli in the honey bee mushroom bodies do not predict performance on a foraging task.

    Science.gov (United States)

    Van Nest, Byron N; Wagner, Ashley E; Marrs, Glen S; Fahrbach, Susan E

    2017-09-01

    The mushroom bodies (MBs) are insect brain regions important for sensory integration, learning, and memory. In adult worker honey bees (Apis mellifera), the volume of neuropil associated with the MBs is larger in experienced foragers compared with hive bees and less experienced foragers. In addition, the characteristic synaptic structures of the calycal neuropils, the microglomeruli, are larger but present at lower density in 35-day-old foragers relative to 1-day-old workers. Age- and experience-based changes in plasticity of the MBs are assumed to support performance of challenging tasks, but the behavioral consequences of brain plasticity in insects are rarely examined. In this study, foragers were recruited from a field hive to a patch comprising two colors of otherwise identical artificial flowers. Flowers of one color contained a sucrose reward mimicking nectar; flowers of the second were empty. Task difficulty was adjusted by changing flower colors according to the principle of honey bee color vision space. Microglomerular volume and density in the lip (olfactory inputs) and collar (visual inputs) compartments of the MB calyces were analyzed using anti-synapsin I immunolabeling and laser scanning confocal microscopy. Foragers displayed significant variation in microglomerular volume and density, but no correlation was found between these synaptic attributes and foraging performance. © 2017 Wiley Periodicals, Inc. Develop Neurobiol 77: 1057-1071, 2017. © 2017 Wiley Periodicals, Inc.

  8. Right and Left Ventricular Volumes in Atrial Septal Defect Studied by Radiocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Ivancevic, D. [Radioisotope Department, Internal Clinic, Rebro, Zagreb, Yugoslavia (Croatia); Vernejoul, P. de; Kellershohn, C. [CEA, Service Hospitalier Frederic Joliot, Departement de Biologie, Orsay (France)

    1971-02-15

    Radiocardiography with radioiodinated ({sup 131}I) human serum albumin and barium ({sup 137m}Ba) solution injected into the right subclavian vein has been performed in a group of 43 patients with atrial septal defect and left-to-right shunt. Data on the output and ejection index of each ventricle are essential for the estimation of the diastolic and residual volumes of the right and left ventricle. The systemic flow was therefore calculated according to Veall's formula and the pulmonary flow and the shunt How were determined using the method of de Vernejoul and co-workers. The formulas for the calculation of ventricular volumes were modified. The results show that many cases of atrial septal defect have an enlarged right ventricle whereas the left ventricle remains normal or is diminished. These changes correlate well with the amount of the shunt flow. In both ventricles the ventricular volumes show a good correlation with the stroke volumes. For the regulation of the pulmonary blood volume the right ventricle seems to be more important than the left ventricle. The operative closure of atrial septal defect (in 14 patients) has normalized the size of ventricular volumes. (author)

  9. Grey-matter volume as a potential feature for the classification of Alzheimer's disease and mild cognitive impairment: an exploratory study.

    Science.gov (United States)

    Guo, Yane; Zhang, Zengqiang; Zhou, Bo; Wang, Pan; Yao, Hongxiang; Yuan, Minshao; An, Ningyu; Dai, Haitao; Wang, Luning; Zhang, Xi; Liu, Yong

    2014-06-01

    Specific patterns of brain atrophy may be helpful in the diagnosis of Alzheimer's disease (AD). In the present study, we set out to evaluate the utility of grey-matter volume in the classification of AD and amnestic mild cognitive impairment (aMCI) compared to normal control (NC) individuals. Voxel-based morphometric analyses were performed on structural MRIs from 35 AD patients, 27 aMCI patients, and 27 NC participants. A two-sample two-tailed t-test was computed between the NC and AD groups to create a map of abnormal grey matter in AD. The brain areas with significant differences were extracted as regions of interest (ROIs), and the grey-matter volumes in the ROIs of the aMCI patients were included to evaluate the patterns of change across different disease severities. Next, correlation analyses between the grey-matter volumes in the ROIs and all clinical variables were performed in aMCI and AD patients to determine whether they varied with disease progression. The results revealed significantly decreased grey matter in the bilateral hippocampus/parahippocampus, the bilateral superior/middle temporal gyri, and the right precuneus in AD patients. The grey-matter volumes were positively correlated with clinical variables. Finally, we performed exploratory linear discriminative analyses to assess the classifying capacity of grey-matter volumes in the bilateral hippocampus and parahippocampus among AD, aMCI, and NC. Leave-one-out cross-validation analyses demonstrated that grey-matter volumes in hippocampus and parahippocampus accurately distinguished AD from NC. These findings indicate that grey-matter volumes are useful in the classification of AD.

  10. Trans-Caspian gas pipeline feasibility study. Volume 1

    International Nuclear Information System (INIS)

    1999-01-01

    This study, conducted by Enron Engineering and Construction Company, was funded by the US Trade and Development Agency. The study provides detailed information concerning natural gas demand in Turkey and Southern Europe. The purpose of the study is to estimate the rate at which new gas can be absorbed in the Turkish market and be re-exported to the markets in Europe, as well as to forecast Turkish natural gas demand for the period up to 2020. The study also evaluates gas demand and pricing for the market in the 2002--2005 time frame. This is Volume 1 of a 3-volume report, and is divided into the following sections: (1) Task A: Gas Sales; (2) Task B: Initial Economic Screening; (3) Task D: Project Cost Analysis

  11. The acute effects of manipulating volume and load of back squats on countermovement vertical jump performance.

    Science.gov (United States)

    Moir, Gavin L; Mergy, David; Witmer, Ca; Davis, Shala E

    2011-06-01

    The acute effects of manipulating the volume and load of back squats on subsequent countermovement vertical jump performance were investigated in the present study. Eleven National Collegiate Athletic Association division II female volleyball players performed 10 countermovement vertical jumps (CMJs) on a force platform 2 minutes after the last squat repetition of a high-load (HL) or high-volume (HV) squat protocol. Two minutes of rest was provided between each CMJ. The HL protocol culminated in the subjects having to perform 3 repetitions with a load equivalent to 90% 1 repetition maximum (1RM) back squat, whereas 12 repetitions with a load equivalent to 37% 1RM were performed in the HV protocol. During an initial familiarization session, knee angles were recorded during a series of CMJs, and these angles were used to control the depth of descent during all subsequent back squats. Jump height (JH) and vertical stiffness (VStiff) were calculated during each of the 10 CMJ, and the change in these variables after the 2 squat protocols was assessed using an analysis of variance model with repeated measures on 2 factors (Protocol [2-levels]; Time [2-levels]). There was no significant difference in JH after the HL and HV protocols (p > 0.05). A significant Protocol × Time interaction for VStiff resulted from the increase after the HL protocol being greater than that after the HV protocol (p = 0.03). The knee angles before the HL and HV protocols were significantly greater than those measured during the initial familiarization session (p = 0.001). Although neither squat protocol provided any benefit in improving JH, the heavy squat protocol produced greater increases in VStiff during the CMJ. Because of the increased VStiff caused by the HL protocol, volleyball coaches may consider using such protocols with their players to improve performance in jumps performed from a run such as the spike and on-court agility.

  12. Energy Performance and Pressure Fluctuation of a Multiphase Pump with Different Gas Volume Fractions

    Directory of Open Access Journals (Sweden)

    Jinsong Zhang

    2018-05-01

    Full Text Available Large petroleum resources in deep sea, and huge market demands for petroleum need advanced petroleum extraction technology. The multiphase pump, which can simultaneously transport oil and gas with considerable efficiency, has been a crucial technology in petroleum extraction. A numerical approach with mesh generation and a Navier-Stokes equation solution is employed to evaluate the effects of gas volume fraction on energy performance and pressure fluctuations of a multiphase pump. Good agreement of experimental and calculation results indicates that the numerical approach can accurately simulate the multiphase flow in pumps. The pressure rise of a pump decreases with the increasing of flow rate, and the pump efficiency decreases with the increasing of GVF (the ratio of the gas volume to the whole volume. Results show that the dominant frequencies of pressure fluctuation in the impeller and diffuser are eleven and three times those of the impeller rotational frequency, respectively. Due to the larger density of water and centrifugal forces, the water aggregates to the shroud and the gas gathers to the hub, which renders the distribution of GVF in the pump uneven. A vortex develops at the blade suction side, near the leading edge, induced by the leakage flow, and further affects the pressure fluctuation in the impeller. The obvious vortex in the diffuser indicates that the design of the divergence angle of the diffuser is not optimal, which induces flow separation due to large diffusion ratio. A uniform flow pattern in the impeller indicates good hydraulic performance of the pump.

  13. An Experimental Study of High Strength-High Volume Fly Ash Concrete for Sustainable Construction Industry

    Science.gov (United States)

    Kate, Gunavant K.; Thakare, Sunil B., Dr.

    2017-08-01

    Concrete is the most widely used building material in the construction of infrastructures such as buildings, bridges, highways, dams, and many other facilities. This paper reports the development, the basic idea, the main properties of high strength-high volume fly ash with application in concrete associated with the development and implementation of Sustainable Properties of High Volume Fly Ash Concrete (HVFAC) Mixtures and Early Age Shrinkage and mechanical properties of concrete for 7,28,56 and 90days. Another alternative to make environment-friendly concrete is the development of high strength-high-volume fly ash concrete which is an synthesized from materials of geological origin or by-product materials such as fly ash which is rich in silicon and aluminum. In this paper 6 concrete mixtures were produced to evaluate the effect of key parameters on the mechanical properties of concrete and its behavior. The study key parameters are; binder material content, cement replacement ratios, and the steel fibers used to High Volume Fly Ash mixtures for increasing performance of concrete.

  14. Comprehensive Cooling Water Study. Volume 1. Summary of environmental effects, Savannah River Plant. Annual report

    International Nuclear Information System (INIS)

    Gladden, J.B.; Lower, M.W.; Mackey, H.E.; Specht, W.L.; Wilde, E.W.

    1985-07-01

    This volume summarizes the technical content of Volumes II through XI of the annual report. Volume II provides a description of the SRP environment, facilities, and operation, and presents the objectives and design for the CCWS. Volume III presents information on water quality of SRP surface waters. Results of radionuclide and heavy metal transport studies are presented in Volume IV. Volume V contains findings from studies of wetland plant communities. Volume VI presents findings from studies of the lower food chain components of SRP aquatic habitats. The results of fisheries studies are reported in Volume VII. Studies of semi-aquatic vertebrate populations are reported in Volume VIII. Water-fowl utilization of SRP habitats is discussed in Volume IX. The status of endangered species that utilize SRP aquatic habitats is presented in Volume X. The findings from studies of Parr Pond ecosystem are presented in Volume XI

  15. "Pulmonary valve replacement diminishes the presence of restrictive physiology and reduces atrial volumes": a prospective study in Tetralogy of Fallot patients.

    Science.gov (United States)

    Pijuan-Domenech, Antonia; Pineda, Victor; Castro, Miguel Angel; Sureda-Barbosa, Carlos; Ribera, Aida; Cruz, Luz M; Ferreira-Gonzalez, Ignacio; Dos-Subirà, Laura; Subirana-Domènech, Teresa; Garcia-Dorado, David; Casaldàliga-Ferrer, Jaume

    2014-11-15

    Pulmonary valve replacement (PVR) reduces right ventricular (RV) volumes in the setting of long-term pulmonary regurgitation after Tetralogy of Fallot (ToF) repair; however, little is known of its effect on RV diastolic function. Right atrial volumes may reflect the burden of RV diastolic dysfunction. The objective of this paper is to evaluate the clinical, echocardiographic, biochemical and cardiac magnetic resonance (CMR) variables, focusing particularly on right atrial response and right ventricular diastolic function prior to and after elective PVR in adult patients with ToF. This prospective study was conducted from January 2009 to April 2013 in consecutive patients > 18 years of age who had undergone ToF repair in childhood and were accepted for elective PVR. Twenty patients (mean age: 35 years; 70% men) agreed to enter the study. PVR was performed with a bioporcine prosthesis. Concomitant RV reduction was performed in all cases when technically possible. Pulmonary end-diastolic forward flow (EDFF) decreased significantly from 5.4 ml/m(2) to 0.3 ml/m(2) (p volumes by 25% (p = 0.0024): mean indexed diastolic/systolic atrial volumes prior to surgery were 43 ml/m(2) (SD+/-4.6)/63 ml/m(2) (SD+/-5.5), and dropped to 33 ml/m(2) (SD+/-3)/46 ml/m(2) (SD+/-2.55) post-surgery. All patients presented right ventricular diastolic and systolic volume reductions, with a mean volume reduction of 35% (p volumes in keeping with the known reduction in RV volumes, after PVR. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. A meta-analysis of randomized controlled trials of low-volume polyethylene glycol plus ascorbic acid versus standard-volume polyethylene glycol solution as bowel preparations for colonoscopy.

    Directory of Open Access Journals (Sweden)

    Qingsong Xie

    Full Text Available BACKGROUND: Standard-volume polyethylene glycol (PEG gut lavage solutions are safe and effective, but they require the consumption of large volumes of fluid. A new lower-volume solution of PEG plus ascorbic acid has been used recently as a preparation for colonoscopy. AIM: A meta-analysis was performed to compare the performance of low-volume PEG plus ascorbic acid with standard-volume PEG as bowel preparation for colonoscopy. STUDY: Electronic and manual searches were performed to identify randomized controlled trials (RCTs that compared the performance of low-volume PEG plus ascorbic acid with standard-volume PEG as bowel preparation for colonoscopy. After a methodological quality assessment and data extraction, the pooled estimates of bowel preparation efficacy during bowel cleansing, compliance with preparation, willingness to repeat the same preparation, and the side effects were calculated. We calculated pooled estimates of odds ratios (OR by fixed- and/or random-effects models. We also assessed heterogeneity among studies and the publication bias. RESULTS: Eleven RCTs were identified for analysis. The pooled OR for preparation efficacy during bowel cleansing and for compliance with preparation for low-volume PEG plus ascorbic acid were 1.08 (95% CI = 0.98-1.28, P = 0.34 and 2.23 (95% CI = 1.67-2.98, P<0.00001, respectively, compared with those for standard-volume PEG. The side effects of vomiting and nausea for low-volume PEG plus ascorbic acid were reduced relative to standard-volume PEG. There was no significant publication bias, according to a funnel plot. CONCLUSIONS: Low-volume PEG plus ascorbic acid gut lavage achieved non-inferior efficacy for bowel cleansing, is more acceptable to patients, and has fewer side effects than standard-volume PEG as a bowel preparation method for colonoscopy.

  17. Trans-Caspian gas pipeline feasibility study. Volume 3

    International Nuclear Information System (INIS)

    1999-01-01

    This study, conducted by Enron Engineering and Construction Company, was funded by the US Trade and Development Agency. The study provides detailed information concerning natural gas demand in Turkey and Southern Europe. The purpose of the study is to estimate the rate at which new gas can be absorbed in the Turkish market and be re-exported to the markets in Europe, as well as to forecast Turkish natural gas demand for the period up to 2020. The study also evaluates gas demand and pricing for the market in the 2002--2005 time frame. This is Volume 3 of a 3-volume report, and it is divided into the following sections: (1) Executive Summary; (2) Task C: Technical Feasibility and Preliminary Design; (3) Task F: Project Implementation Strategy

  18. Real-time bladder volume monitoring by the application of a new implantable bladder volume sensor for a small animal model

    Directory of Open Access Journals (Sweden)

    Dong Sup Lee

    2011-04-01

    Full Text Available Although real-time monitoring of bladder volume together with intravesical pressure can provide more information for understanding the functional changes of the urinary bladder, it still entails difficulties in the accurate prediction of real-time bladder volume in urodynamic studies with small animal models. We studied a new implantable bladder volume monitoring device with eight rats. During cystometry, microelectrodes prepared by the microelectromechanical systems process were placed symmetrically on both lateral walls of the bladder, and the expanded bladder volume was calculated. Immunohistological study was done after 1 week and after 4 weeks to evaluate the biocompatibility of the microelectrode. From the point that infused saline volume into the bladder was higher than 0.6 mL, estimated bladder volume was statistically correlated with the volume of saline injected (p<0.01. Additionally, the microelectromechanical system microelectrodes used in this study showed reliable biocompatibility. Therefore, the device can be used to evaluate changes in bladder volume in studies with small animals, and it may help to provide more information about functional changes in the bladder in laboratory studies. Furthermore, owing to its biocompatibility, the device could be chronically implanted in conscious ambulating animals, thus allowing a novel longitudinal study to be performed for a specific purpose.

  19. Volumizing effects of a smooth, highly cohesive, viscous 20-mg/mL hyaluronic acid volumizing filler: prospective European study

    Directory of Open Access Journals (Sweden)

    Hoffmann Klaus

    2009-08-01

    Full Text Available Abstract Background Facial volume loss contributes significantly to facial aging. The 20-mg/mL hyaluronic acid (HA formulation used in this study is a smooth, highly cohesive, viscous, fully reversible, volumizing filler indicated to restore facial volume. This first prospective study evaluated use in current aesthetic clinical practice. Methods A pan-European evaluation conducted under guidelines of the World Association of Opinion and Marketing Research, the trial comprised a baseline visit (visit 1 and a follow-up (visit 2 at 14 ± 7 days posttreatment. Physicians photographed patients at each visit. Each patient was treated with the 20-mg/mL HA volumizing filler as supplied in standard packaging. Procedural details, aesthetic outcomes, safety, and physician and patient ratings of their experience were recorded. Results Fifteen physicians and 70 patients (91% female; mean age: 50 years participated. Mean volume loss at baseline was 3.7 (moderate on the Facial Volume Loss Scale. Local anesthesia was used in 64.3% of cases. Most injections (85% were administered with needles rather than cannulas. Of the 208 injections, 59% were in the malar region, primarily above the periosteum. Subcutaneous injections were most common for other sites. The mean total injection volume per patient was 4.6 mL. The mean volume loss score declined significantly (P Conclusion The 20-mg/mL smooth, highly cohesive, viscous, volumizing HA filler was effective, well tolerated, and easy to use in current clinical practice. Participants were very likely to recommend this product to colleagues and friends, and patients would be very or quite likely to request this product for future treatments.

  20. Performance of chip seals using local and minimally processed aggregates for preservation of low traffic volume roadways.

    Science.gov (United States)

    2013-07-01

    This report documents the performance of two low traffic volume experimental chip seals constructed using : locally available, minimally processed sand and gravel aggregates after four winters of service. The projects : were constructed by CDOT maint...

  1. The impact of environmental conditions on human performance: A critical review of the literature. Volume 2

    International Nuclear Information System (INIS)

    Echeverria, D.; Barnes, V.; Bittner, A.

    1994-09-01

    The Battelle Human Affairs Research Centers (HARC) conducted a comprehensive review of the technical literature regarding the impact of environmental conditions on human performance applicable to nuclear power plant workers. The environmental conditions considered were vibration, noise, heat, cold, and light. Research staff identified potential human performance deficits along a continuum of increasing occupational exposure, ranging from deficits that occur at low exposures to deficits that occur at high exposures. Specific deficits were included in the review if scientists demonstrated the exposure caused an effect, using sound methodology. The levels associated with each deficit were then compared to the protection afforded by existing occupational exposure standards. Volume 2 presents several conclusions regarding the applicability of the research literature to environmental conditions in nuclear power plants. The findings presented suggest that occupational standards for vibration, noise, and heat, which were developed to protect health, are inadequate for preventing deficits in cognitive or motor performance in tasks likely to be performed in nuclear power plants. Also, there is little information in the literature on simultaneous conditions; for example, the effects of simultaneous exposure to heat and noise on cognition require more research. As many exposures in nuclear power plants will be simultaneous, this limitation should be kept in mind when using Volume 1

  2. Space shuttle/food system study. Volume 2, appendix E: Alternate flight systems analysis

    Science.gov (United States)

    1974-01-01

    The functional requirements of stowage, preparation, serving, consumption, and cleanup were applied to each of the five food mixes selected for study in terms of the overall design of the space shuttle food system. The analysis led to a definition of performance requirements for each food mix, along with a definition of equipment to meet those requirements. Weight and volume data for all five systems, in terms of food and packaging, support equipment, and galley installation penalties, are presented.

  3. Assessment of the accuracy of ABC/2 variations in traumatic epidural hematoma volume estimation: a retrospective study

    Directory of Open Access Journals (Sweden)

    Pengfei Yan

    2016-04-01

    Full Text Available Background. The traumatic epidural hematoma (tEDH volume is often used to assist in tEDH treatment planning and outcome prediction. ABC/2 is a well-accepted volume estimation method that can be used for tEDH volume estimation. Previous studies have proposed different variations of ABC/2; however, it is unclear which variation will provide a higher accuracy. Given the promising clinical contribution of accurate tEDH volume estimations, we sought to assess the accuracy of several ABC/2 variations in tEDH volume estimation. Methods. The study group comprised 53 patients with tEDH who had undergone non-contrast head computed tomography scans. For each patient, the tEDH volume was automatically estimated by eight ABC/2 variations (four traditional and four newly derived with an in-house program, and results were compared to those from manual planimetry. Linear regression, the closest value, percentage deviation, and Bland-Altman plot were adopted to comprehensively assess accuracy. Results. Among all ABC/2 variations assessed, the traditional variations y = 0.5 × A1B1C1 (or A2B2C1 and the newly derived variations y = 0.65 × A1B1C1 (or A2B2C1 achieved higher accuracy than the other variations. No significant differences were observed between the estimated volume values generated by these variations and those of planimetry (p > 0.05. Comparatively, the former performed better than the latter in general, with smaller mean percentage deviations (7.28 ± 5.90% and 6.42 ± 5.74% versus 19.12 ± 6.33% and 21.28 ± 6.80%, respectively and more values closest to planimetry (18/53 and 18/53 versus 2/53 and 0/53, respectively. Besides, deviations of most cases in the former fell within the range of 20% (90.57% and 96.23, respectively. Discussion. In the current study, we adopted an automatic approach to assess the accuracy of several ABC/2 variations for tEDH volume estimation. Our initial results showed that the variations y = 0.5 × A1B1C1 (or A2B2C1

  4. A prospective study of corpus callosum regional volumes and neurocognitive outcomes following cranial radiation for pediatric brain tumors.

    Science.gov (United States)

    Rashid, Arif; Ram, Ashwin N; Kates, Wendy R; Redmond, Kristin J; Wharam, Moody; Mark Mahone, E; Horska, Alena; Terezakis, Stephanie

    2017-06-01

    Cranial radiation therapy (CRT) may disrupt the corpus callosum (CC), which plays an important role in basic motor and cognitive functions. The aim of this prospective longitudinal study was to assess changes in CC mid-sagittal areas, CC volumes, and performance on neuropsychological (NP) tests related to the CC in children following CRT. Twelve pediatric patients were treated with CRT for primary brain malignancies. Thirteen age-matched healthy volunteers served as controls. Brain MRIs and NP assessment emphasizing motor dexterity, processing speed, visuomotor integration, and working memory (visual and verbal) were performed at baseline and at 6, 15, and 27 months following completion of CRT. Linear mixed effects (LME) analyses were used to evaluate patient NP performance and changes in regional CC volumes (genu, anterior body, mid-body, posterior body, and splenium) and mid-sagittal areas over time and with radiation doses, correcting for age at CRT start. The mean age at CRT was 9.41 (range 1.2-15.7) years. The median prescription dose was 54 (range 18-59.4) Gy. LME analysis revealed a significant decrease in overall CC volumes over time (p memory (both p memory. Further prospective study of larger cohorts of patients is needed to establish the relationship between CRT dose, neuroanatomical, and functional changes in the CC.

  5. Study on the High Volume Reduction of Radioactive Wastes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Hong; Sik, Kang Il; Seok, Hong Dae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ho, Jeon Gil [RADIN Co. Ltd., Daejeon (Korea, Republic of)

    2013-10-15

    The solidification of radioactive wastes by the mixing method always increases their volume due to the limitation of incorporation ratio (waste/solidification agent). But if the powdered wastes can be compacted as the high density pellets and also the pellets can be filled up in a waste drum as much as possible while solidifying them with a very sticky solidification agent including a void formed in the filling step of pellets, it might be more desirable to reduce the waste volume as compared with the mixing method. So in this study, we designed and manufactured a high volume reduction machine which has the special size and shape of a pellet pocket, which the pellets can be extracted from easily and filled up in a large amount in drum, a pressurizing device to press 2 rolls, and the uniform feeding device of powder to the roll tyre. Some operational parameters which affect the formation of pellets from a powder were investigated, and then the volume reduction of a powder was evaluated. The briquetting machine, popular in general industry, was modified to apply for the volume reduction of the powered radioactive wastes (dried concentrate, sludge, spent ion-exchange resin, ash, depleted uranium powder, and etc.). In this developed high volume reduction machine, the capacity was 25 ∼ 62.5 kg/h at the optimum conditions, and the estimated volume reduction was about 2.95 (2.74/0.93) on the basis of between a powder (bulk density = 0.93 g/cm{sup 3}) and the pellet (2.74 g/cm{sup 3}). But on the basis of 200L drum, the calculated volume reduction was about 1.34 in consideration of a void volume originated in the filling step of the pellets.

  6. Comparison of 2 weekly-equalized volume resistance-training routines using different frequencies on body composition and performance in trained males.

    Science.gov (United States)

    Yue, Fu Leon; Karsten, Bettina; Larumbe-Zabala, Eneko; Seijo, Marcos; Naclerio, Fernando

    2018-05-01

    The present study compared the effects of 2 weekly-equalized volume and relative load interventions on body composition, strength, and power. Based on individual baseline maximal strength values, 18 recreationally trained men were pair-matched and consequently randomly assigned to one of the following experimental groups: a low volume per session with a high frequency (LV-HF, n = 9) group who trained for 4 days (Mondays, Tuesdays, Thursdays, and Fridays) or a high volume per session and low frequency (HV-LF, n = 9) group who trained for 2 days (Mondays and Thursdays). Both groups performed 2 different routines over 6 weeks. Participants were tested pre- and post- intervention for maximal strength, upper body power, fat-free mass, limb circumferences, and muscle thickness. Compared with baseline values, both groups increased their fat-free mass (HV-LF: +1.19 ± 1.94; LV-HF: +1.36 ± 1.06 kg, p squat (LV-HF: +0.14 ± 0.06; HV-LF: 0.17 ± 0.01 kg·body mass -1 ) exercises as well as in upper body power (LV-HF: +0.22 ± 0.25; HV-LF: +0.27 ± 0.22 W·body mass -1 ) Although both training strategies improved performance and lower body muscle mass, only the HV-LF protocol increased upper body hypertrophy and improved body composition.

  7. An experimental study on the excitation of large volume airguns in a small volume body of water

    International Nuclear Information System (INIS)

    Wang, Baoshan; Yang, Wei; Yuan, Songyong; Ge, Hongkui; Chen, Yong; Guo, Shijun; Xu, Ping

    2010-01-01

    A large volume airgun array is effective in generating seismic waves, which is extensively used in large volume bodies of water such as oceans, lakes and reservoirs. So far, the application of large volume airguns is subject to the distribution of large volume bodies of water. This paper reports an attempt to utilize large volume airguns in a small body of water as a seismic source for seismotectonic studies. We carried out a field experiment in Mapaoquan pond, Fangshan district, Beijing, during the period 25–30 May 2009. Bolt LL1500 airguns, each with volumes of 2000 in 3 , the largest commercial airguns available today, were used in this experiment. We tested the excitation of the airgun array with one or two guns. The airgun array was placed 7–11 m below the water's surface. The near- and far-field seismic motions induced by the airgun source were recorded by a 100 km long seismic profile composed of 16 portable seismometers and a 100 m long strong motion seismograph profile, respectively. The following conclusions can be drawn from this experiment. First, it is feasible to excite large volume airguns in a small volume body of water. Second, seismic signals from a single shot of one airgun can be recognized at the offset up to 15 km. Taking advantage of high source repeatability, we stacked records from 128 shots to enhance the signal-to-noise ratio, and direct P-waves can be easily identified at the offset ∼50 km in stacked records. Third, no detectable damage to fish or near-field constructions was caused by the airgun shots. Those results suggest that large volume airguns excited in small bodies of water can be used as a routinely operated seismic source for mid-scale (tens of kilometres) subsurface explorations and monitoring under various running conditions

  8. Systems Studies Department FY 78 activity report. Volume 2. Systems analysis

    International Nuclear Information System (INIS)

    Gold, T.S.

    1979-02-01

    The Systems Studies Department at Sandia Laboratories Livermore (SLL) has two primary responsibilities: to provide computational and mathematical services and to perform systems analysis studies. This document (Volume 2) describes the FY Systems Analysis highlights. The description is an unclassified overview of activities and is not complete or exhaustive. The objective of the systems analysis activities is to evaluate the relative value of alternative concepts and systems. SLL systems analysis activities reflect Sandia Laboratory programs and in 1978 consisted of study efforts in three areas: national security: evaluations of strategic, theater, and navy nuclear weapons issues; energy technology: particularly in support of Sandia's solar thermal programs; and nuclear fuel cycle physical security: a special project conducted for the Nuclear Regulatory Commission. Highlights of these activities are described in the following sections. 7 figures

  9. Aperiodic Volume Optics

    Science.gov (United States)

    Gerke, Tim D.

    Presented in this thesis is an investigation into aperiodic volume optical devices. The three main topics of research and discussion are the aperiodic volume optical devices that we call computer-generated volume holograms (CGVH), defects within periodic 3D photonic crystals, and non-periodic, but ordered 3D quasicrystals. The first of these devices, CGVHs, are designed and investigated numerically and experimentally. We study the performance of multi-layered amplitude computer-generated volume holograms in terms of efficiency and angular/frequency selectivity. Simulation results show that such aperiodic devices can increase diffraction efficiency relative to periodic amplitude volume holograms while maintaining angular and wavelength selectivity. CGVHs are also designed as voxelated volumes using a new projection optimization algorithm. They are investigated using a volumetric diffraction simulation and a standard 3D beam propagation technique as well as experimentally. Both simulation and experiment verify that the structures function according to their design. These represent the first diffractive structures that have the capacity for generating arbitrary transmission and reflection wave fronts and that provide the ability for multiplexing arbitrary functionality given different illumination conditions. Also investigated and discussed in this thesis are 3D photonic crystals and quasicrystals. We demonstrate that these devices can be fabricated using a femtosecond laser direct writing system that is particularly appropriate for fabrication of such arbitrary 3D structures. We also show that these devices can provide 3D partial bandgaps which could become complete bandgaps if fabricated using high index materials or by coating lower index materials with high index metals. Our fabrication method is particularly suited to the fabrication of engineered defects within the periodic or quasi-periodic systems. We demonstrate the potential for fabricating defects within

  10. Personality factors in flight operations. Volume 1: Leader characteristics and crew performance in a full-mission air transport simulation

    Science.gov (United States)

    Chidester, Thomas R.; Kanki, Barbara G.; Foushee, H. Clayton; Dickinson, Cortlandt L.; Bowles, Stephen V.

    1990-01-01

    Crew effectiveness is a joint product of the piloting skills, attitudes, and personality characteristics of team members. As obvious as this point might seem, both traditional approaches to optimizing crew performance and more recent training development highlighting crew coordination have emphasized only the skill and attitudinal dimensions. This volume is the first in a series of papers on this simulation. A subsequent volume will focus on patterns of communication within crews. The results of a full-mission simulation research study assessing the impact of individual personality on crew performance is reported. Using a selection algorithm described in previous research, captains were classified as fitting one of three profiles along a battery of personality assessment scales. The performances of 23 crews led by captains fitting each profile were contrasted over a one-and-one-half-day simulated trip. Crews led by captains fitting a positive Instrumental-Expressive profile (high achievement motivation and interpersonal skill) were consistently effective and made fewer errors. Crews led by captains fitting a Negative Expressive profile (below average achievement motivation, negative expressive style, such as complaining) were consistently less effective and made more errors. Crews led by captains fitting a Negative Instrumental profile (high levels of competitiveness, verbal aggressiveness, and impatience and irritability) were less effective on the first day but equal to the best on the second day. These results underscore the importance of stable personality variables as predictors of team coordination and performance.

  11. Improved Short-Term Outcomes following Orthognathic Surgery Are Associated with High-Volume Centers.

    Science.gov (United States)

    Berlin, Nicholas L; Tuggle, Charles T; Steinbacher, Derek M

    2016-08-01

    Previous studies assessing outcomes following orthognathic surgery rely primarily on single-center/surgeon experience. In addition to issues of generalizability, these studies are limited in evaluating the effect of operative volume on patient outcomes. Orthognathic procedures were identified in the 1999 to 2011 Healthcare Cost and Utilization Project Nationwide Inpatient Sample. Outcomes included occurrence of any in-hospital complication, extended length of stay (>2 days), and increased costs (>$10,784). High-volume hospitals were defined as the 90th percentile of case volume or higher (>31 cases/year). Univariate and multivariate analyses were conducted to identify independent predictors of outcomes. Trend analyses were performed to assess changes in the annual rate of patients treated at high-volume hospitals over the study period. Among 101,692 orthognathic surgery patients, 19.6 percent underwent concurrent ancillary procedures (i.e., genioplasty, rhinoplasty, or septoplasty), and 37.6 percent underwent double-jaw surgery. Fifty-three percent were treated at high-volume hospitals. High-volume hospitals more often performed ancillary procedures (21.4 percent versus 17.4 percent; p surgery (41.3 percent versus 33.4 percent; p orthognathic cases nationwide are performed at a small number of high-volume hospitals. These hospitals discharge patients earlier, perform more complex procedures, and have fewer complications. Risk, III.

  12. Gross tumor volume and clinical target volume: soft-tissue sarcoma of the extremities

    International Nuclear Information System (INIS)

    Lartigau, E.; Kantor, G.; Lagarde, P.; Taieb, S.; Ceugnart, L.; Vilain, M.O.; Penel, N.; Depadt, G.

    2001-01-01

    Soft tissue sarcomas of the extremities are currently treated with more conservative and functional approaches, combining surgery, radiotherapy and chemotherapy. The role of external beam radiotherapy and brachytherapy has been defined through randomized studies performed in the 80's and 90's. However, the ubiquity of tumour location for these tumours makes difficult a systematic definition of local treatments. Tumour volume definition is based on pre and post surgical imaging (MRI) and on described pathological report. The clinical target volume will take into account quality of the resection and anatomical barriers and will be based on an anatomy and not only on safety margins around the tumour bed. General rules for this irradiation (doses, volumes) and principal results will be presented. (authors)

  13. Disc volume reduction with percutaneous nucleoplasty in an animal model.

    Directory of Open Access Journals (Sweden)

    Richard Kasch

    Full Text Available STUDY DESIGN: We assessed volume following nucleoplasty disc decompression in lower lumbar spines from cadaveric pigs using 7.1Tesla magnetic resonance imaging (MRI. PURPOSE: To investigate coblation-induced volume reductions as a possible mechanism underlying nucleoplasty. METHODS: We assessed volume following nucleoplastic disc decompression in pig spines using 7.1-Tesla MRI. Volumetry was performed in lumbar discs of 21 postmortem pigs. A preoperative image data set was obtained, volume was determined, and either disc decompression or placebo therapy was performed in a randomized manner. Group 1 (nucleoplasty group was treated according to the usual nucleoplasty protocol with coblation current applied to 6 channels for 10 seconds each in an application field of 360°; in group 2 (placebo group the same procedure was performed but without coblation current. After the procedure, a second data set was generated and volumes calculated and matched with the preoperative measurements in a blinded manner. To analyze the effectiveness of nucleoplasty, volumes between treatment and placebo groups were compared. RESULTS: The average preoperative nucleus volume was 0.994 ml (SD: 0.298 ml. In the nucleoplasty group (n = 21 volume was reduced by an average of 0.087 ml (SD: 0.110 ml or 7.14%. In the placebo group (n = 21 volume was increased by an average of 0.075 ml (SD: 0.075 ml or 8.94%. The average nucleoplasty-induced volume reduction was 0.162 ml (SD: 0.124 ml or 16.08%. Volume reduction in lumbar discs was significant in favor of the nucleoplasty group (p<0.0001. CONCLUSIONS: Our study demonstrates that nucleoplasty has a volume-reducing effect on the lumbar nucleus pulposus in an animal model. Furthermore, we show the volume reduction to be a coblation effect of nucleoplasty in porcine discs.

  14. Effectiveness evaluation of two volumizing hyaluronic acid dermal fillers in a controlled, randomized, double-blind, split-face clinical study

    Directory of Open Access Journals (Sweden)

    Kerscher M

    2017-06-01

    Full Text Available Martina Kerscher,1 Karla Agsten,2 Maria Kravtsov,3 Welf Prager4 1Department of Cosmetic Science, University of Hamburg, 2SCIderm GmbH, Hamburg, Germany; 3Anteis S.A., Geneva, Switzerland; 4Prager & Partner Dermatologische Praxis, Hamburg, Germany Background: Enhancement of the midface can be achieved with volumizing hyaluronic acid (HA fillers.Objective: The objective of this study was to compare the safety and effectiveness of Cohesive Polydensified Matrix® 26 mg/mL HA gel (CPM-26 and Vycross® 20 mg/ml HA gel (VYC-20 in a controlled, randomized, evaluator-blind, split-face clinical study.Patients and methods: Subjects with moderate-to-severe malar volume loss on the Merz Aesthetics Scale (MAS received CPM-26 on one side and VYC-20 on the contralateral side of the face. Effectiveness assessments were performed by blinded evaluators including photographic and live MAS ratings and live Global Aesthetic Improvement Scale (GAIS ratings. Calculations of anatomical volume variations at month 3 (M3, month 6 (M6, month 12 (M12 and month 18 (M18 were also performed.Results: Non-inferiority of CPM-26 versus VYC-20 was demonstrated at M3 (primary end point based on MAS. GAIS rating showed that significantly more subjects had better improvement with CPM-26 than with VYC-20 at month 1, M3, M12 and M18 (p=0.0032, p=0.0074, p=0.0384 and p=0.0110, respectively. Standardized evaluation of volume variations from baseline to M3, M12 and M18 showed that CPM-26 created more volume augmentation at all time points, and the difference was significant at M3.Conclusion: CPM-26 was non-inferior to VYC-20 based on MAS ratings at M3 and demonstrated a favorable safety and effectiveness profile for midfacial volume enhancement with results lasting up to M18. Keywords: cohesive polydensified matrix, hyaluronic acid fillers, Belotero® Volume, Modélis® SHAPE, Juvéderm® VOLUMA®, volumizing

  15. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Joscha, E-mail: joscha.maier@dkfz.de [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Sawall, Stefan; Kachelrieß, Marc [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany and Institute of Medical Physics, University of Erlangen–Nürnberg, 91052 Erlangen (Germany)

    2014-05-15

    Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the

  16. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

    International Nuclear Information System (INIS)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-01-01

    Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the

  17. Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure.

    Science.gov (United States)

    Maier, Joscha; Sawall, Stefan; Kachelrieß, Marc

    2014-05-01

    Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the

  18. Volume 2. Probabilistic analysis of HTGR application studies. Supporting data

    International Nuclear Information System (INIS)

    1980-09-01

    Volume II, Probabilistic Analysis of HTGR Application Studies - Supporting Data, gives the detail data, both deterministic and probabilistic, employed in the calculation presented in Volume I. The HTGR plants and the fossil plants considered in the study are listed. GCRA provided the technical experts from which the data were obtained by MAC personnel. The names of the technical experts (interviewee) and the analysts (interviewer) are given for the probabilistic data

  19. Learning process for performing and analyzing 3D/4D transperineal ultrasound imaging and interobserver reliability study.

    Science.gov (United States)

    Siafarikas, F; Staer-Jensen, J; Braekken, I H; Bø, K; Engh, M Ellström

    2013-03-01

    To evaluate the learning process for acquiring three- and four-dimensional (3D/4D) transperineal ultrasound volumes of the levator hiatus (LH) dimensions at rest, during pelvic floor muscle (PFM) contraction and on Valsalva maneuver, and for analyzing the ultrasound volumes, as well as to perform an interobserver reliability study between two independent ultrasound examiners. This was a prospective study including 22 women. We monitored the learning process of an inexperienced examiner (IE) performing 3D/4D transperineal ultrasonography and analyzing the volumes. The examination included acquiring volumes during three PFM contractions and three Valsalva maneuvers. LH dimensions were determined in the axial plane. The learning process was documented by estimating agreement between the IE and an experienced examiner (E) using the intraclass correlation coefficient. Agreement was calculated in blocks of 10 ultrasound examinations and analyzed volumes. After the learning process was complete the interobserver reliability for the technique was calculated between these two independent examiners. For offline analysis of the first 10 ultrasound volumes obtained by E, good to very good agreement between E and IE was achieved for all LH measurements except for the left and right levator-urethra gap and pubic arc. For the next 10 analyzed volumes, agreement improved for all LH measurements. Volumes that had been obtained by IE and E were then re-evaluated by IE, and good to very good agreement was found for all LH measurements indicating consistency in volume acquisition. The interobserver reliability study showed excellent ICC values (ICC, 0.81-0.97) for all LH measurements except the pubic arc (ICC = 0.67). 3D/4D transperineal ultrasound is a reliable technique that can be learned in a short period of time. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  20. Blanket comparison and selection study. Volume II

    International Nuclear Information System (INIS)

    1983-10-01

    This volume contains extensive data for the following chapters: (1) solid breeder tritium recovery, (2) solid breeder blanket designs, (3) alternate blanket concept screening, and (4) safety analysis. The following appendices are also included: (1) blanket design guidelines, (2) power conversion systems, (3) helium-cooled, vanadium alloy structure blanket design, (4) high wall loading study, and (5) molten salt safety studies

  1. Effects of Two Different Volume-Equated Weekly Distributed Short-Term Plyometric Training Programs on Futsal Players' Physical Performance.

    Science.gov (United States)

    Yanci, Javier; Castillo, Daniel; Iturricastillo, Aitor; Ayarra, Rubén; Nakamura, Fábio Y

    2017-07-01

    Yanci, J, Castillo, D, Iturricastillo, A, Ayarra, R, and Nakamura, FY. Effects of two different volume-equated weekly distributed short-term plyometric training programs on futsal players' physical performance. J Strength Cond Res 31(7): 1787-1794, 2017-The aim was to analyze the effect of 2 different plyometric training programs (i.e., 1 vs. 2 sessions per week, same total weekly volume) on physical performance in futsal players. Forty-four futsal players were divided into 3 training groups differing in weekly plyometric training load: the 2 days per week plyometric training group (PT2D, n = 15), the 1 day per week plyometric training group (PT1D, n = 12), and the control group (CG, n = 12) which did not perform plyometric training. The results of this study showed that in-season futsal training per se was capable of improving repeat sprint ability (RSA) (effect size [ES] = -0.59 to -1.53). However, while change of direction ability (CODA) was maintained during the training period (ES = 0.00), 15-m sprint (ES = 0.73), and vertical jump (VJ) performance (ES = -0.30 to -1.37) were significantly impaired. By contrast, PT2D and PT1D plyometric training were effective in improving futsal players' 15-m sprint (ES = -0.64 to -1.00), CODA (ES = -1.83 to -5.50), and horizontal jump (ES = 0.33-0.64) performance. Nonetheless, all groups (i.e., PT2D, PT1D, and CG) presented a reduction in VJ performance (ES = -0.04 to -1.37). Regarding RSA performance, PT1D showed a similar improvement compared with CG (ES = -0.65 to -1.53) after the training intervention, whereas PT2D did not show significant change (ES = -0.04 to -0.38). These results may have considerable practical relevance for the optimal design of plyometric training programs for futsal players, given that a 1-day-per-week plyometric training program is more efficient than a 2-day-per-week plyometric training program to improve the futsal players' physical performance.

  2. Metabolically active tumour volume segmentation from dynamic [(18)F]FLT PET studies in non-small cell lung cancer.

    Science.gov (United States)

    Hoyng, Lieke L; Frings, Virginie; Hoekstra, Otto S; Kenny, Laura M; Aboagye, Eric O; Boellaard, Ronald

    2015-01-01

    Positron emission tomography (PET) with (18)F-3'-deoxy-3'-fluorothymidine ([(18)F]FLT) can be used to assess tumour proliferation. A kinetic-filtering (KF) classification algorithm has been suggested for segmentation of tumours in dynamic [(18)F]FLT PET data. The aim of the present study was to evaluate KF segmentation and its test-retest performance in [(18)F]FLT PET in non-small cell lung cancer (NSCLC) patients. Nine NSCLC patients underwent two 60-min dynamic [(18)F]FLT PET scans within 7 days prior to treatment. Dynamic scans were reconstructed with filtered back projection (FBP) as well as with ordered subsets expectation maximisation (OSEM). Twenty-eight lesions were identified by an experienced physician. Segmentation was performed using KF applied to the dynamic data set and a source-to-background corrected 50% threshold (A50%) was applied to the sum image of the last three frames (45- to 60-min p.i.). Furthermore, several adaptations of KF were tested. Both for KF and A50% test-retest (TRT) variability of metabolically active tumour volume and standard uptake value (SUV) were evaluated. KF performed better on OSEM- than on FBP-reconstructed PET images. The original KF implementation segmented 15 out of 28 lesions, whereas A50% segmented each lesion. Adapted KF versions, however, were able to segment 26 out of 28 lesions. In the best performing adapted versions, metabolically active tumour volume and SUV TRT variability was similar to those of A50%. KF misclassified certain tumour areas as vertebrae or liver tissue, which was shown to be related to heterogeneous [(18)F]FLT uptake areas within the tumour. For [(18)F]FLT PET studies in NSCLC patients, KF and A50% show comparable tumour volume segmentation performance. The KF method needs, however, a site-specific optimisation. The A50% is therefore a good alternative for tumour segmentation in NSCLC [(18)F]FLT PET studies in multicentre studies. Yet, it was observed that KF has the potential to subsegment

  3. The Effect of Plyometric Training Volume on Athletic Performance in Prepubertal Male Soccer Players.

    Science.gov (United States)

    Chaabene, Helmi; Negra, Yassine

    2017-10-01

    To assess and compare the effects of 8 wk of in-season (2 sessions/wk) low- and high-volume plyometric training (PT) on measures of physical fitness in prepubertal male soccer players. A total of 25 soccer players were randomly assigned to a low-volume PT group (LPT; n = 13, age 12.68 ± 0.23 y, age at peak height velocity [APHV] 14.25 ± 0.29 y, maturity offset -1.57 ± 0.29 y) or a high-volume PT group (HPT; n = 12, age 12.72 ± 0.27 y, APHV 14.33 ± 0.77 y, maturity offset -1.61 ± 0.76 y). A linear-sprint test (5-m, 10-m, 20-m, and 30-m), change-of-direction (CoD) test, and vertical- (squat-jump [SJ]), countermovement- (CMJ), and horizontal-jump (standing long jump [SLJ]) test were carried out before and after 8 wk of PT. There was a significant main effect of time for sprint outcomes (5-m, P = .005, ES = 0.86; 10-m, P = .006, ES = 0.85; 20-m, P = .03, ES = 0.64, and 30-m, P = .05, ES = 0.57), CoD (P = .002, ES = 0.96), SJ (P = .008, ES = 0.81; CMJ, P = .01, ES = 0.73), and SLJ ability (P = .007, ES = 0.83). There were no significant training group × time interactions in any measured outcomes. After 8 wk of training, results showed similar performance improvement on measures of sprint time, CoD, and jumping ability between LPT and HPT groups. From a time-efficiency perspective, it is recommended to use LPT in prepubertal male soccer players to improve their proxies of athletic performance.

  4. Pad-weighing test performed with standardized bladder volume

    DEFF Research Database (Denmark)

    Lose, G; Rosenkilde, P; Gammelgaard, J

    1988-01-01

    The result of the one-hour pad-weighing test proposed by the International Continence Society has been demonstrated to depend on the urine load during the test. To increase reproducibility of the pad-weighing test by minimizing the influence of variation in urine load the test was done with a sta...... to +/- 24 g between two tests. It is concluded that this setup (i.e., standardized bladder volume) of the one-hour pad-weighing test allows for a more reliable assessment of urinary incontinence for quantitative purposes....... with a standardized bladder volume (50% of the cystometric bladder capacity). Twenty-five female patients with stress or mixed incontinence underwent two separate tests. Test-retest results were highly correlated (r = 0.97, p less than 0.001). Nonetheless, analysis of test-retest differences revealed a variation up...

  5. High Energy Performance Tests of Large Volume LaBr{sub 3}:Ce Detector

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A.; Gondal, M.A.; Khiari, F.Z.; Dastageer, M.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Maslehuddin, M.M. [Center for Engineering Research, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2015-07-01

    High energy prompt gamma ray tests of a large volume cylindrical 100 mm x 100 mm (height x diameter) LaBr{sub 3}:Ce detector were carried out using a portable neutron generator-based Prompt Gamma Neutron Activation Analysis (PGNAA) setup. In this study prompt gamma-rays yield were measured from water samples contaminated with toxic elements such nickel, chromium and mercury compounds with gamma ray energies up to 10 MeV. The experimental yield of prompt gamma-rays from toxic elements were compared with the results of Monte Carlo calculations. In spite of its higher intrinsic background due to its larger volume, an excellent agreement between the experimental and calculated yields of high energy gamma-rays from Ni, Cr and Hg samples has been achieved for the large volume LaBr{sub 3}:Ce detector. (authors)

  6. [Hippocampal subfield volume alteration in post-traumatic stress disorder: a magnetic resonance imaging study].

    Science.gov (United States)

    Lu, Lu; Zhang, Lianqing; Hu, Xinyu; Hu, Xiaoxiao; Li, Lingjiang; Gong, Qiyong; Huang, Xiaoqi

    2018-04-01

    In the current study, we aim to investigate whether post-traumatic stress disorder (PTSD) is associated with structural alterations in specific subfields of hippocampus comparing with trauma-exposed control (TC) in a relatively large sample. We included 67 PTSD patients who were diagnosed under Diagnostic and Statistical Manual of Mental Disorders (4th Edition) (DSM-Ⅳ) criteria and 78 age- and sex-matched non-PTSD adult survivors who experienced similar stressors. High resolution T1 weighted images were obtained via a GE 3.0 T scanner. The structural data was automatically segmented using FreeSurfer software, and volume of whole hippocampus and subfield including CA1, CA2-3, CA4-DG, fimbria, presubiculum, subiculum and fissure were extracted. Volume differences between the two groups were statistically compared with age, years of education, duration from the events and intracranial volume (ICV) as covariates. Hemisphere, sex and diagnosis were entered as fixed factors. Relationship between morphometric measurements with Clinician-Administered PTSD Scale (CAPS) score and illness duration were performed using Pearson's correlation with SPSS. Comparing to TC, PTSD patients showed no statistically significant alteration in volumes of the whole hippocampus and all the subfields ( P > 0.05). In male patients, there were significant correlations between CAPS score and volume of right CA2-3 ( R 2 = 0.197, P = 0.034), right subiculum ( R 2 = 0.245, P = 0.016), and duration statistically correlated with right fissure ( R 2 = 0.247, P = 0.016). In female patients, CAPS scores significant correlated with volume of left presubiculum ( R 2 = 0.095, P = 0.042), left subiculum ( R 2 = 0.090, P = 0.048), and left CA4-DG ( R 2 = 0.099, P = 0.037). The main findings of the current study suggest that stress event causes non-selective damage to hippocampus in both PTSD patients and TC, and gender-specific lateralization may underlie PTSD pathology.

  7. Longitudinal study of hippocampal volumes in heavy cannabis users.

    Science.gov (United States)

    Koenders, L; Lorenzetti, V; de Haan, L; Suo, C; Vingerhoets, Wam; van den Brink, W; Wiers, R W; Meijer, C J; Machielsen, Mwj; Goudriaan, A E; Veltman, D J; Yücel, M; Cousijn, J

    2017-08-01

    Cannabis exposure, particularly heavy cannabis use, has been associated with neuroanatomical alterations in regions rich with cannabinoid receptors such as the hippocampus in some but not in other (mainly cross-sectional) studies. However, it remains unclear whether continued heavy cannabis use alters hippocampal volume, and whether an earlier age of onset and/or a higher dosage exacerbate these changes. Twenty heavy cannabis users (mean age 21 years, range 18-24 years) and 23 matched non-cannabis using healthy controls were submitted to a comprehensive psychological assessment and magnetic resonance imaging scan at baseline and at follow-up (average of 39 months post-baseline; standard deviation=2.4). Cannabis users started smoking around 16 years and smoked on average five days per week. A novel aspect of the current study is that hippocampal volume estimates were obtained from manual tracing the hippocampus on T1-weighted anatomical magnetic resonance imaging scans, using a previously validated protocol. Compared to controls, cannabis users did not show hippocampal volume alterations at either baseline or follow-up. Hippocampal volumes increased over time in both cannabis users and controls, following similar trajectories of increase. Cannabis dose and age of onset of cannabis use did not affect hippocampal volumes. Continued heavy cannabis use did not affect hippocampal neuroanatomical changes in early adulthood. This contrasts with prior evidence on alterations in this region in samples of older adult cannabis users. In young adults using cannabis at this level, cannabis use may not be heavy enough to affect hippocampal neuroanatomy.

  8. Performance of Leak Compensation in All-Age ICU Ventilators During Volume-Targeted Neonatal Ventilation: A Lung Model Study.

    Science.gov (United States)

    Itagaki, Taiga; Bennett, Desmond J; Chenelle, Christopher T; Fisher, Daniel F; Kacmarek, Robert M

    2017-01-01

    Volume-targeted ventilation is increasingly used in low birthweight infants because of the potential for reducing volutrauma and avoiding hypocapnea. However, it is not known what level of air leak is acceptable during neonatal volume-targeted ventilation when leak compensation is activated concurrently. Four ICU ventilators (Servo-i, PB980, V500, and Avea) were compared in available invasive volume-targeted ventilation modes (pressure control continuous spontaneous ventilation [PC-CSV] and pressure control continuous mandatory ventilation [PC-CMV]). The Servo-i and PB980 were tested with (+) and without (-) their proximal flow sensor. The V500 and Avea were tested with their proximal flow sensor as indicated by their manufacturers. An ASL 5000 lung model was used to simulate 4 neonatal scenarios (body weight 0.5, 1, 2, and 4 kg). The ASL 5000 was ventilated via an endotracheal tube with 3 different leaks. Two minutes of data were collected after each change in leak level, and the asynchrony index was calculated. Tidal volume (V T ) before and after the change in leak was assessed. The differences in delivered V T between before and after the change in leak were within ±5% in all scenarios with the PB980 (-/+) and V500. With the Servo-i (-/+), baseline V T was ≥10% greater than set V T during PC-CSV, and delivered V T markedly changed with leak. The Avea demonstrated persistent high V T in all leak scenarios. Across all ventilators, the median asynchrony index was 1% (interquartile range 0-27%) in PC-CSV and 1.8% (0-45%) in PC-CMV. The median asynchrony index was significantly higher in the Servo-i (-/+) than in the PB980 (-/+) and V500 in 1 and 2 kg scenarios during PC-CSV and PC-CMV. The PB980 and V500 were the only ventilators to acclimate to all leak scenarios and achieve targeted V T . Further clinical investigation is needed to validate the use of leak compensation during neonatal volume-targeted ventilation. Copyright © 2017 by Daedalus Enterprises.

  9. Anatomical basis of the extended TDAP flap: study of its territories of vascularization and its volume.

    Science.gov (United States)

    Dast, Sandy; Havet, Eric; Dessena, Lidia; Abdulshakoor, Abeer; Alharbi, Mohammed; Vaucher, Richard; Herlin, Christian; Sinna, Raphael

    2017-08-01

    The concept of extended thoracodorsal artery perforator (TDAP) flap was described in 2015 for breast reconstruction. Our anatomical study aims to identify the territories vascularised by the thoracodorsal artery perforator via the deep muscular fascial network. The second goal was to define the volume of the extended TDAP flap. Ten extended TDAP flaps were dissected on 5 fresh human cadavers. Around the classical skin paddle of a TDAP flap, the dissections were performed in a subfascial level, including the muscular fascia and the adipose tissue compartments to increase the volume of the flap. After injection of methylene blue in the thoracodorsal artery, we measured the length and width, the surface and the volume of the coloured flap. The mean sizes of the extended TDAP flap were 24.9 cm × 20.1 cm. The mean surface of the total vascularization zone was 441 cm 2 . The mean volume of the vascularized flap was 193 ml. The thoracodorsal artery perforator via the deep muscular fascial network allows us to harvest a flap of 25 cm × 20 cm with a mean surface of 441 cm² and a mean volume of 193 ml. The extended TDAP flap is a credible option in breast reconstruction.

  10. Post-mortem virtual estimation of free abdominal blood volume

    International Nuclear Information System (INIS)

    Ampanozi, Garyfalia; Hatch, Gary M.; Ruder, Thomas D.; Flach, Patricia M.; Germerott, Tanja; Thali, Michael J.; Ebert, Lars C.

    2012-01-01

    Purpose: The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. Materials and methods: Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the blood was estimated using a manual segmentation technique (Amira, Visage Imaging, Germany) and the results were compared to autopsy data. Six of 21 cases had undergone additional post-mortem computed tomographic angiography (PMCTA). Results: The virtually estimated abdominal blood volumes did not differ significantly from those measured at autopsy. Additional PMCTA did not bias data significantly. Conclusion: Virtual estimation of abdominal blood volume is a reliable technique. The virtual blood volume estimation is a useful tool to deliver additional information in cases where autopsy is not performed or in cases where a postmortem angiography is performed

  11. Trans-Caspian gas pipeline feasibility study. Volume 2

    International Nuclear Information System (INIS)

    1999-01-01

    This study, conducted by Enron Engineering and Construction Company, was funded by the US Trade and Development Agency. The study provides detailed information concerning natural gas demand in Turkey and Southern Europe. The purpose of the study is to estimate the rate at which new gas can be absorbed in the Turkish market and be re-exported to the markets in Europe, as well as to forecast Turkish natural gas demand for the period up to 2020. The study also evaluates gas demand and pricing for the market in the 2002--2005 time frame. This is Volume 2 of a 3-volume report, and it is divided into the following sections: (1) Executive Summary; (2) Policy, Legal and Administrative Framework; (3) Assessment of Alternatives; (4) Baseline Conditions in the Project Area; (5) Potential (Unmitigated) Environment, Health and Safety Impacts; (6) Proposed Environmental Prevention and Mitigation; (7) Projected Net Environmental Impacts; (8) Bibliography

  12. Scintigraphic And Ultrasonic Determinations of Thyroid Volume

    International Nuclear Information System (INIS)

    Sarsono; Ismanto; Kunto, W; Hayati, N; Irma, S H

    1996-01-01

    A study has been done on the determination of thyroid volume by scintigraphic method in comparison to ultrasonographic technique, which involved a healthy woman volunteer, 5 women patients and a man patient with thyroid diseases. Scintigraphic examination upon the patient's thyroid was performed using a gamma camera 20 minutes following the injection of 55.5 Mbq (1.5 mCi) Tc-99m pertechnetate. A computer, with a dedicated program, coupled to the gamma camera was employed in the calculation of thyroid volume based on the scintigraphic data. Subsequent to the scintigraphic study, ultrasonographic determination of thyroid volume was then carried out. Correlation test that was applied to the outcome of the two methods of thyroid volume determination resulted in an excellent coefficient of correlation, R, which was 0.99. This showed a very good correlation between these two different techniques of thyroid volume determination

  13. BWR spent fuel storage cask performance test. Volume 2. Pre- and post-test decay heat, heat transfer, and shielding analyses

    International Nuclear Information System (INIS)

    Wiles, L.E.; Lombardo, N.J.; Heeb, C.M.; Jenquin, U.P.; Michener, T.E.; Wheeler, C.L.; Creer, J.M.; McCann, R.A.

    1986-06-01

    This report describes the decay heat, heat transfer, and shielding analyses conducted in support of performance testing of a Ridhihalgh, Eggers and Associates REA 2033 boiling water reactor (BWR) spent fuel storage cask. The cask testing program was conducted for the US Department of Energy (DOE) Commercial Spent Fuel Management Program by the Pacific Northwest Laboratory (PNL) and by General Electric at the latters' Morris Operation (GE-MO) as reported in Volume I. The analyses effort consisted of performing pretest calculations to (1) select spent fuel for the test; (2) symmetrically load the spent fuel assemblies in the cask to ensure lateral symmetry of decay heat generation rates; (3) optimally locate temperature and dose rate instrumentation in the cask and spent fuel assemblies; and (4) evaluate the ORIGEN2 (decay heat), HYDRA and COBRA-SFS (heat transfer), and QAD and DOT (shielding) computer codes. The emphasis of this second volume is on the comparison of code predictions to experimental test data in support of the code evaluation process. Code evaluations were accomplished by comparing pretest (actually pre-look, since some predictions were not completed until testing was in progress) predictions with experimental cask testing data reported in Volume I. No attempt was made in this study to compare the two heat transfer codes because results of other evaluations have not been completed, and a comparison based on one data set may lead to erroneous conclusions

  14. A longitudinal study of brain volume changes in normal aging

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Hidemasa, E-mail: takaoh-tky@umin.ac.jp [Department of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 (Japan); Hayashi, Naoto [Department of Computational Diagnostic Radiology and Preventive Medicine, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 (Japan); Ohtomo, Kuni [Department of Radiology, Graduate School of Medicine, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655 (Japan)

    2012-10-15

    Purpose: To evaluate the effect of normal aging on brain volumes and examine the effects of age and sex on the rates of changes in global and regional brain volumes. Methods: A total of 199 normal subjects (65 females and 134 males, mean age = 56.4 ± 9.9 years, age range = 38.1–82.9 years) were included in this study. Each subject was scanned twice, at an interval of about 2 years (range = 1.5–2.3 years). Two-time-point percentage brain volume change (PBVC) was estimated with SIENA 2.6. Results: The mean annualized PBVC was −0.23%/y. Analysis of covariance (ANCOVA) for annual brain volume changes revealed a main effect of age. There was no main effect of sex, nor was there a sex-by-age interaction. Voxel-wise analysis revealed a negative correlation between age and edge displacement values mainly in the periventricular region. Conclusions: The results of our study indicate that brain atrophy accelerates with increasing age and that there is no gender difference in the rate of brain atrophy.

  15. A longitudinal study of brain volume changes in normal aging

    International Nuclear Information System (INIS)

    Takao, Hidemasa; Hayashi, Naoto; Ohtomo, Kuni

    2012-01-01

    Purpose: To evaluate the effect of normal aging on brain volumes and examine the effects of age and sex on the rates of changes in global and regional brain volumes. Methods: A total of 199 normal subjects (65 females and 134 males, mean age = 56.4 ± 9.9 years, age range = 38.1–82.9 years) were included in this study. Each subject was scanned twice, at an interval of about 2 years (range = 1.5–2.3 years). Two-time-point percentage brain volume change (PBVC) was estimated with SIENA 2.6. Results: The mean annualized PBVC was −0.23%/y. Analysis of covariance (ANCOVA) for annual brain volume changes revealed a main effect of age. There was no main effect of sex, nor was there a sex-by-age interaction. Voxel-wise analysis revealed a negative correlation between age and edge displacement values mainly in the periventricular region. Conclusions: The results of our study indicate that brain atrophy accelerates with increasing age and that there is no gender difference in the rate of brain atrophy

  16. Intrathecal volume changes in lumbar spinal canal stenosis following extension and flexion: An experimental cadaver study.

    Science.gov (United States)

    Teske, Wolfram; Schwert, Martin; Zirke, Sonja; von Schulze Pellengahr, Christoph; Wiese, Matthias; Lahner, Matthias

    2015-01-01

    The spinal canal stenosis is a common disease in elderly. The thecal sac narrowing is considered as the anatomical cause for the disease. There is evidence that the anatomical proportions of the lumbar spinal canal are influenced by postural changes. The liquor volume shift during these postural changes is a valuable parameter to estimate the dynamic qualities of this disease. The aim of this human cadaver study was the determination of intrathecal fluid volume changes during the lumbar flexion and the extension. A special measuring device was designed and built for the study to investigate this issue under controlled conditions. The measuring apparatus fixed the lumbar spine firmly and allowed only flexion and extension. The dural sac was closed water tight. The in vitro changes of the intrathecal volumes during the motion cycle were determined according to the principle of communicating vessels. Thirteen human cadaver spines from the Institute of Anatomy were examined in a test setting with a continuous adjustment of motion. The diagnosis of the lumbar spinal stenosis was confirmed by a positive computer tomography prior testing. The volume changes during flexion and extension cycles were measured stepwise in a 2 degree distance between 18° flexion and 18° extension. Three complete series of measurements were performed for each cadaver. Two specimens were excluded because of fluid leaks from further investigation. The flexion of the lumbar spine resulted in an intrathecal volume increase. The maximum volume effects were seen in the early flexion positions of 2° and 4°. The spine reclination resulted in a volume reduction. The maximum extension effect was seen between 14° and 16°. According to our results, remarkable volume effects were seen in the early movements of the lumbar spine especially for the flexion. The results support the concept of the spinal stenosis as a dynamic disease and allow a better understanding of the pathophysiology of this

  17. Brain-volume changes in young and middle-aged smokers: a DARTEL-based voxel-based morphometry study.

    Science.gov (United States)

    Peng, Peng; Wang, Zhenchang; Jiang, Tao; Chu, Shuilian; Wang, Shuangkun; Xiao, Dan

    2017-09-01

    Many studies have reported brain volume changes in smokers. However, the volume differences of grey matter (GM) and white matter (WM) in young and middle-aged male smokers with different lifetime tobacco consumption (pack-years) remain uncertain. To examine the brain volume change, especially whether more pack-years smoking would be associated with smaller gray matter and white matter volume in young and middle-aged male smokers. We used a 3T MR scanner and performed Diffeomorphic anatomical registration through exponentiated lie algebra (DARTEL)-based voxel-based morphometry on 53 long-term male smokers (30.72 ± 4.19 years) and 53 male healthy non-smokers (30.83 ± 5.18 years). We separated smokers to light and heavy smokers by pack-years and compared brain volume between different smoker groups and non-smokers. And then we did analysis of covariance (ANCOVA) between smokers and non-smokers by setting pack-years as covariates. Light and heavy smokers all displayed smaller GM and WM volume than non-smokers and more obviously in heavy smokers. The main smaller areas in light and heavy smokers were superior temporal gyrus, insula, middle occipital gyrus, posterior cingulate, precuneus in GM and posterior cingulate, thalamus and midbrain in WM, in addition, we also observed more pack-years smoking was associated with some certain smaller GM and WM volumes by ANCOVA. Young and middle-aged male smokers had many smaller brain areas than non-smokers. Some of these areas' volume had negative correlation with pack-years, while some had not. These may due to different pathophysiological role of smokings. © 2015 John Wiley & Sons Ltd.

  18. Studies of left ventricular volume estimation from single photon emission computed tomography

    International Nuclear Information System (INIS)

    Hiraki, Yoshio; Shimizu, Mitsuharu; Joja, Ikuo; Aono, Kaname; Yanagi, Hidekiyo; Indo, Haruaki; Seno, Yoshimasa; Teramoto, Shigeru; Nagaya, Isao.

    1988-01-01

    We studied the comparative accuracy of 99m Tc cardiac blood pool Single Photon Emission Computed Tomography (SPECT) for the measurement of left ventricular volume in 20 patients undergoing SPECT and single plane contrast left ventriculography (LVG). Left ventricular volume was calculated based on the total number of voxels in left ventricle. End-diastolic left ventricular volume (EDV) and end-systolic left ventricular volume (ESV) calculated from SPECT were compared with those from LVG. SPECT volume values showed a high degree of correlation with those by LVG (r = 0.923 for EDV, r = 0.903 for ESV). We appreciated the usefulness and accuracy of SPECT in measuring left ventricular volume because of its three-dimensional information. (author)

  19. Basketball training increases striatum volume.

    Science.gov (United States)

    Park, In Sung; Lee, Kea Joo; Han, Jong Woo; Lee, Nam Joon; Lee, Won Teak; Park, Kyung Ah; Rhyu, Im Joo

    2011-02-01

    The striatum is associated with the learning and retention of motor skills. Several studies have shown that motor learning induces neuronal changes in the striatum. We investigated whether macroscopic change in striatum volume occurs in a segment of the human population who learned basketball-related motor skills and practiced them throughout their entire athletic life. Three-dimensional magnetic resonance imaging volumetry was performed in basketball players and healthy controls, and striatum volumes were compared based on basketball proficiency, region and side. We identified morphological enlargement in the striatum of basketball players in comparison with controls. Our results suggest that continued practice and repetitive performance of basketball-related motor skills may induce plastic structural changes in the human striatum. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Adrenal gland volume measurement in septic shock and control patients: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Nougaret, Stephanie; Aufort, S.; Gallix, B. [Hopital Saint Eloi, Department of Abdominal Imaging, CHU Montpellier, Montpellier, Cedex 5 (France); Jung, B.; Chanques, G.; Jaber, S. [Hopital Saint Eloi, Intensive Care Unit, Department of Critical Care and Anesthesiology: DAR B, CHU Montpellier, Montpellier, Cedex 5 (France)

    2010-10-15

    To compare adrenal gland volume in septic shock patients and control patients by using semi-automated volumetry. Adrenal gland volume and its inter-observer variability were measured with tomodensitometry using semi-automated software in 104 septic shock patients and in 40 control patients. The volumes of control and septic shock patients were compared and the relationship between volume and outcome in intensive care was studied. The mean total volume of both adrenal glands was 7.2 {+-} 2.0 cm{sup 3} in control subjects and 13.3 {+-} 4.7 cm{sup 3} for total adrenal gland volume in septic shock patients (p < 0.0001). Measurement reproducibility was excellent with a concordance correlation coefficient value of 0.87. The increasing adrenal gland volume was associated with a higher rate of survival in intensive care. The present study reports that with semi-automated software, adrenal gland volume can be measured easily and reproducibly. Adrenal gland volume was found to be nearly double in sepsis compared with control patients. The absence of increased volume during sepsis would appear to be associated with a higher rate of mortality and may represent a prognosis factor which may help the clinician to guide their strategy. (orig.)

  1. Adrenal gland volume measurement in septic shock and control patients: a pilot study

    International Nuclear Information System (INIS)

    Nougaret, Stephanie; Aufort, S.; Gallix, B.; Jung, B.; Chanques, G.; Jaber, S.

    2010-01-01

    To compare adrenal gland volume in septic shock patients and control patients by using semi-automated volumetry. Adrenal gland volume and its inter-observer variability were measured with tomodensitometry using semi-automated software in 104 septic shock patients and in 40 control patients. The volumes of control and septic shock patients were compared and the relationship between volume and outcome in intensive care was studied. The mean total volume of both adrenal glands was 7.2 ± 2.0 cm 3 in control subjects and 13.3 ± 4.7 cm 3 for total adrenal gland volume in septic shock patients (p < 0.0001). Measurement reproducibility was excellent with a concordance correlation coefficient value of 0.87. The increasing adrenal gland volume was associated with a higher rate of survival in intensive care. The present study reports that with semi-automated software, adrenal gland volume can be measured easily and reproducibly. Adrenal gland volume was found to be nearly double in sepsis compared with control patients. The absence of increased volume during sepsis would appear to be associated with a higher rate of mortality and may represent a prognosis factor which may help the clinician to guide their strategy. (orig.)

  2. Change in brain and lesion volumes after CEE therapies: the WHIMS-MRI studies.

    Science.gov (United States)

    Coker, Laura H; Espeland, Mark A; Hogan, Patricia E; Resnick, Susan M; Bryan, R Nick; Robinson, Jennifer G; Goveas, Joseph S; Davatzikos, Christos; Kuller, Lewis H; Williamson, Jeff D; Bushnell, Cheryl D; Shumaker, Sally A

    2014-02-04

    To determine whether smaller brain volumes in older women who had completed Women's Health Initiative (WHI)-assigned conjugated equine estrogen-based hormone therapy (HT), reported by WHI Memory Study (WHIMS)-MRI, correspond to a continuing increased rate of atrophy an average of 6.1 to 7.7 years later in WHIMS-MRI2. A total of 1,230 WHI participants were contacted: 797 (64.8%) consented, and 729 (59%) were rescanned an average of 4.7 years after the initial MRI scan. Mean annual rates of change in total brain volume, the primary outcome, and rates of change in ischemic lesion volumes, the secondary outcome, were compared between treatment groups using mixed-effect models with adjustment for trial, clinical site, age, intracranial volumes, and time between MRI measures. Total brain volume decreased an average of 3.22 cm(3)/y in the active arm and 3.07 cm(3)/y in the placebo arm (p = 0.53). Total ischemic lesion volumes increased in both arms at a rate of 0.12 cm(3)/y (p = 0.88). Conjugated equine estrogen-based postmenopausal HT, previously assigned at WHI baseline, did not affect rates of decline in brain volumes or increases in brain lesion volumes during the 4.7 years between the initial and follow-up WHIMS-MRI studies. Smaller frontal lobe volumes were observed as persistent group differences among women assigned to active HT compared with placebo. Women with a history of cardiovascular disease treated with active HT, compared with placebo, had higher rates of accumulation in white matter lesion volume and total brain lesion volume. Further study may elucidate mechanisms that explain these findings.

  3. Parsing partial molar volumes of small molecules: a molecular dynamics study.

    Science.gov (United States)

    Patel, Nisha; Dubins, David N; Pomès, Régis; Chalikian, Tigran V

    2011-04-28

    We used molecular dynamics (MD) simulations in conjunction with the Kirkwood-Buff theory to compute the partial molar volumes for a number of small solutes of various chemical natures. We repeated our computations using modified pair potentials, first, in the absence of the Coulombic term and, second, in the absence of the Coulombic and the attractive Lennard-Jones terms. Comparison of our results with experimental data and the volumetric results of Monte Carlo simulation with hard sphere potentials and scaled particle theory-based computations led us to conclude that, for small solutes, the partial molar volume computed with the Lennard-Jones potential in the absence of the Coulombic term nearly coincides with the cavity volume. On the other hand, MD simulations carried out with the pair interaction potentials containing only the repulsive Lennard-Jones term produce unrealistically large partial molar volumes of solutes that are close to their excluded volumes. Our simulation results are in good agreement with the reported schemes for parsing partial molar volume data on small solutes. In particular, our determined interaction volumes() and the thickness of the thermal volume for individual compounds are in good agreement with empirical estimates. This work is the first computational study that supports and lends credence to the practical algorithms of parsing partial molar volume data that are currently in use for molecular interpretations of volumetric data.

  4. Radiological status of the Saint-Pierre (Cantal) uranium mine and of its environment. Volume 1 + volume 2 + volume 3

    International Nuclear Information System (INIS)

    2006-01-01

    The first volume reports detailed investigations performed by the CRIIRAD (sampling and radiological controls of sediments, and more particularly of waters and aquatic plants) in different areas about the Saint-Pierre uranium mine in France (Cantal department). Measurements were performed by gamma spectrometry. The second part concerns external exposure and the radiological characterization of soils. The third part reports the study of the presence of radon in outdoor and indoor air. For each of these aspects, methodological information is given as well as a great quantity of measurement results

  5. Performance evaluation of the technical capabilities of DOE sites for disposal of mixed low-level waste. Volume 2: Technical basis and discussion of results

    International Nuclear Information System (INIS)

    Waters, R.D.; Gruebel, M.M.; Hospelhorn, M.B.

    1996-03-01

    A team of analysts designed and conducted a performance evaluation to estimate the technical capabilities of fifteen Department of Energy sites for disposal of mixed low-level waste (i.e., waste that contains both low-level radioactive materials and hazardous constituents). Volume 1 summarizes the process for selecting the fifteen sites, the methodology used in the evaluation, and the conclusions derived from the evaluation. Volume 2 first describes the screening process used to determine the sites to be considered in the PEs. This volume then provides the technical details of the methodology for conducting the performance evaluations. It also provides a comparison and analysis of the overall results for all sites that were evaluated. Volume 3 contains detailed evaluations of the fifteen sites and discussions of the results for each site

  6. Liver volume, intrahepatic fat and body weight in the course of a lifestyle interventional study. Analysis with quantitative MR-based methods

    International Nuclear Information System (INIS)

    Bongers, M.N.; Stefan, N.; Fritsche, A.; Haering, H.U.; Nikolaou, K.; Schick, F.; Machann, J.

    2015-01-01

    The aim of this study was to investigate potential associations between changes in liver volume, the amount of intrahepatic lipids (IHL) and body weight during lifestyle interventions. In a prospective study 150 patients with an increased risk for developing type 2 diabetes mellitus were included who followed a caloric restriction diet for 6 months. In the retrospective analysis 18 women and 9 men (age range 22-71 years) with an average body mass index (BMI) of 32 kg/m 2 were enrolled. The liver volume was determined at the beginning and after 6 months by three-dimensional magnetic resonance imaging (3D-MRI, echo gradient, opposed-phase) and IHLs were quantified by volume-selective MR spectroscopy in single voxel stimulated echo acquisition mode (STEAM). Univariable and multivariable correlation analyses between changes of liver volume (Δliver volume), intrahepatic lipids (ΔIHL) and body weight (ΔBW) were performed. Univariable correlation analysis in the whole study cohort showed associations between ΔIHL and ΔBW (r = 0.69; p < 0.0001), ΔIHL and Δliver volume (r = 0.66; p = 0.0002) as well as ΔBW and Δliver volume (r = 0.5; p = 0.0073). Multivariable correlation analysis revealed that changes of liver volume are primarily determined by changes in IHL independent of changes in body weight (β = 0.0272; 95 % CI: 0.0155-0.034; p < 0.0001). Changes of liver volume during lifestyle interventions are independent of changes of body weight primarily determined by changes of IHL. These results show the reversibility of augmented liver volume in steatosis if it is possible to reduce IHLs during lifestyle interventions. (orig.) [de

  7. 1000-Case Reader Study of Radiologists' Performance in Interpretation of Automated Breast Volume Scanner Images with a Computer-Aided Detection System.

    Science.gov (United States)

    Xu, Xiaojing; Bao, Lingyun; Tan, Yanjuan; Zhu, Luoxi; Kong, Fanlei; Wang, Wei

    2018-05-28

    The objective of our study was to assess, in a reader study, radiologists' performance in interpretation of automated breast volume scanner (ABVS) images with the aid of a computer-aided detection (CADe) system. Our study is a retrospective observer study with the purpose of investigating the effectiveness of using a CADe system as an aid for radiologists in interpretation of ABVS images. The multiple-reader, multiple-case study was designed to compare the diagnostic performance of radiologists with and without CADe. The study included 1000 cases selected from ABVS examinations in our institution in 2012. Among those cases were 206 malignant, 486 benign and 308 normal cases. The cancer cases were consecutive; the benign and normal cases were randomly selected. All malignant and benign cases were confirmed by biopsy or surgery, and normal cases were confirmed by 2-y follow-up. Reader performance was compared in terms of area under the receiver operating characteristic curve, sensitivity and specificity. Additionally, the reading time per case for each reader was recorded. Nine radiologists from our institution participated in the study. Three had more than 8 y of ultrasound experience and more than 4 y of ABVS experience (group A); 3 had more than 5 y of ultrasound experience (group B), and 3 had more than 1 y of ultrasound experience (group C). Both group B and group C had no ABVS experience. The CADe system used was the QVCAD System (QView Medical, Inc., Los Altos, CA, USA). It is designed to aid radiologists in searching for suspicious areas in ABVS images. CADe results are presented to the reader simultaneously with the ABVS images; that is, the radiologists read the ABVS images concurrently with the CADe results. The cases were randomly assigned for each reader into two equal-size groups, 1 and 2. Initially the readers read their group 1 cases with the aid of CADe and their group 2 cases without CADe. After a 1-mo washout period, they re-read their group 1

  8. Breast cancer screening in Italy: evaluating key performance indicators for time trends and activity volumes.

    Science.gov (United States)

    Giordano, Livia; Castagno, Roberta; Giorgi, Daniela; Piccinelli, Cristiano; Ventura, Leonardo; Segnan, Nereo; Zappa, Marco

    2015-01-01

    Together with the National centre for screening monitoring (ONS), GISMa supports annual collection of data on national breast screening activities. Aggregated data on implementation and performance are gathered through a standardized form to calculate process and impact indicators. Analyzed data belong to 153 local programmes in the period 2006-2011 (2006-2012 for participation rate only). During the whole period, Italian crude participation rate exceeded GISMa's acceptable standard (50%), even though a higher participation in northern and central Italy compared to southern Italy and Islands was observed. Time trend analysis of diagnostic indicators confirmed in 2011 an adequate quality of breast screening performance, especially at subsequent screening. Recall rate at initial screening did not reach the acceptable standard (performance was achieved at subsequent screening. The same trend was followed by the overall detection rate and positive predictive value. They both showed a progressive reduction (from 6.2‰ in 2006 to 4.5‰ in 2011 for DR and from 8.0% in 2006 to 5.2% in 2011 for PPV, respectively) at initial screening and a good, stable trend at subsequent screening. Activity volume analysis shows that in programmes with greater activity (test/year ≥10,000) RR at both initial and subsequent screening has a better performance. This is also true for DR and PPV where programmes with high volumes of activity do better, especially when compared with those that interpret fewer than 5,000 mammograms per year. In spite of a few limits, these results are reassuring, and they reward the efforts made by screening professionals. It is therefore important to continue to monitor screening indicators and suggest, test, and evaluate new strategies for continuous improvement.

  9. Interobserver variability in gross tumor volume delineation for hepatocellular carcinoma. Results of Korean Radiation Oncology Group 1207 study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Suk [Jeju National University School of Medicine, Department of Radiation Oncology, Jeju National University Hospital, Jeju (Korea, Republic of); Kim, Jun Won; Lee, Ik Jae [Yonsei University College of Medicine, Department of Radiation Oncology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Yoon, Won Sup [Korea University Medical Center, Department of Radiation Oncology, Ansan Hospital, Ansan (Korea, Republic of); Kang, Min Kyu [Kyungpook National University School of Medicine, Department of Radiation Oncology, Daegu (Korea, Republic of); Kim, Tae Hyun [National Cancer Center, Center for Liver Cancer, Goyang (Korea, Republic of); Kim, Jin Hee [Keimyung University School of Medicine, Department of Radiation Oncology, Dongsan Medical Center, Daegu (Korea, Republic of); Lee, Hyung-Sik [Dong-A University College of Medicine, Department of Radiation Oncology, Busan (Korea, Republic of); Park, Hee Chul [Sungkyunkwan University School of Medicine, Department of Radiation Oncology, Samsung Medical Center, Seoul (Korea, Republic of); Jang, Hong Seok; Kay, Chul Seung [The Catholic University of Korea College of Medicine, Department of Radiation Oncology, Seoul (Korea, Republic of); Yoon, Sang Min [University of Ulsan College of Medicine, Department of Radiation Oncology, Asan Medical Center, Seoul (Korea, Republic of); Kim, Mi-Sook [Korea Institute of Radiological and Medical Sciences, Department of Radiation Oncology, Seoul (Korea, Republic of); Seong, Jinsil [Yonsei University College of Medicine, Department of Radiation Oncology, Severance Hospital, Seodaemun-gu, Seoul (Korea, Republic of)

    2016-10-15

    There has been increasing use of external beam radiotherapy for localized treatment of hepatocellular carcinoma (HCC) with both palliative and curative intent. Quality control of target delineation in primary HCC is essential to deliver adequate doses of radiation to the primary tumor while preserving adjacent healthy organs. We analyzed interobserver variability in gross tumor volume (GTV) delineation for HCC. Twelve radiation oncologists specializing in liver malignancy participated in a multi-institutional contouring dummy-run study of nine HCC cases and independently delineated GTV on the same set of provided computed tomography images. Quantitative analysis was performed using an expectation maximization algorithm for simultaneous truth and performance level estimation (STAPLE) with kappa statistics calculating agreement between physicians. To quantify the interobserver variability of GTV delineations, the ratio of the actual delineated volume to the estimated consensus volume (STAPLE), the ratio of the common and encompassing volumes, and the coefficient of variation were calculated. The median kappa agreement level was 0.71 (range 0.28-0.86). The ratio of the actual delineated volume to the estimated consensus volume ranged from 0.19 to 1.93 (median 0.94) for all cases. The ratio of the common and encompassing volumes ranged from 0.001 to 0.56 (median 0.25). The coefficient of variation for GTV delineation ranged from 8 to 57 % (median 26 %). The interobserver variability in target delineation of HCC GTV in this study is noteworthy. Multi-institution studies involving radiotherapy for HCC require appropriate quality assurance programs for target delineation. (orig.) [German] Die externe kurative Strahlentherapie ist zunehmend bei der lokalisierten Behandlung hepatozellulaerer Karzinome (HCC) in palliativer und kurativer Absicht in Gebrauch. Eine Qualitaetskontrolle der Zielabgrenzung beim primaeren HCC ist entscheidend, um die passende Dosis fuer die

  10. Exploring Dutch surgeons' views on volume-based policies: a qualitative interview study.

    Science.gov (United States)

    Mesman, Roos; Faber, Marjan J; Westert, Gert P; Berden, Bart

    2018-01-01

    Objective In many countries, the evidence for volume-outcome associations in surgery has been transferred into policy. Despite the large body of research that exists on the topic, qualitative studies aimed at surgeons' views on, and experiences with, these volume-based policies are lacking. We interviewed Dutch surgeons to gain more insight into the implications of volume-outcome policies for daily clinical practice, as input for effective surgical quality improvement. Methods Semi-structured interviews were conducted with 20 purposively selected surgeons from a stratified sample for hospital type and speciality. The interviews were recorded, transcribed verbatim and underwent inductive content analysis. Results Two overarching themes were inductively derived from the data: (1) minimum volume standards and (2) implications of volume-based policies. Although surgeons acknowledged the premise 'more is better', they were critical about the validity and underlying evidence for minimum volume standards. Patients often inquire about caseload, which is met with both understanding and discomfort. Surgeons offered many examples of controversies surrounding the process of determining thresholds as well as the ways in which health insurers use volume as a purchasing criterion. Furthermore, being held accountable for caseload may trigger undesired strategic behaviour, such as unwarranted operations. Volume-based policies also have implications for the survival of low-volume providers and affect patient travel times, although the latter is not necessarily problematic in the Dutch context. Conclusions Surgeons in this study acknowledged that more volume leads to better quality. However, validity issues, undesired strategic behaviour and the ways in which minimum volume standards are established and applied have made surgeons critical of current policy practice. These findings suggest that volume remains a controversial quality measure and causes polarization that is not

  11. Chronic Use of Aspirin and Total White Matter Lesion Volume: Results from the Women's Health Initiative Memory Study of Magnetic Resonance Imaging Study.

    Science.gov (United States)

    Holcombe, Andrea; Ammann, Eric; Espeland, Mark A; Kelley, Brendan J; Manson, JoAnn E; Wallace, Robert; Robinson, Jennifer

    2017-10-01

    To investigate the relationship between aspirin and subclinical cerebrovascular heath, we evaluated the effect of chronic aspirin use on white matter lesions (WML) volume among women. Chronic aspirin use was assessed in 1365 women who participated in the Women's Health Initiative Memory Study of Magnetic Resonance Imaging. Differences in WML volumes between aspirin users and nonusers were assessed with linear mixed models. A number of secondary analyses were performed, including lobe-specific analyses, subgroup analyses based on participants' overall risk of cerebrovascular disease, and a dose-response relationship analysis. The mean age of the women at magnetic resonance imaging examination was 77.6 years. Sixty-one percent of participants were chronic aspirin users. After adjusting for demographic variables and comorbidities, chronic aspirin use was nonsignificantly associated with 4.8% (95% CI: -6.8%, 17.9%) larger WML volumes. These null findings were confirmed in secondary and sensitivity analyses, including an active comparator evaluation where aspirin users were compared to users of nonaspirin nonsteroidal anti-inflammatory drugs or acetaminophen. There was a nonsignificant difference in WML volumes between aspirin users and nonusers. Further, our results suggest that chronic aspirin use may not have a clinically significant effect on WML volumes in women. Published by Elsevier Inc.

  12. Weapons-grade plutonium dispositioning. Volume 1: Executive summary

    International Nuclear Information System (INIS)

    Parks, D.L.; Sauerbrun, T.J.

    1993-06-01

    The Secretary of Energy requested the National Academy of Sciences (NAS) Committee on International Security and Arms Control to evaluate dispositioning options for weapons-grade plutonium. The Idaho National Engineering Laboratory (INEL) assisted NAS in this evaluation by investigating the technical aspects of the dispositioning options and their capability for achieving plutonium annihilation levels greater than 90%. Additionally, the INEL investigated the feasibility of using plutonium fuels (without uranium) for disposal in existing light water reactors and provided a preconceptual analysis for a reactor specifically designed for destruction of weapons-grade plutonium. This four-volume report was prepared for NAS to document the findings of these studies. Volume 2 evaluates 12 plutonium dispositioning options. Volume 3 considers a concept for a low-temperature, low-pressure, low-power-density, low-coolant-flow-rate light water reactor that quickly destroys plutonium without using uranium or thorium. This reactor concept does not produce electricity and has no other mission than the destruction of plutonium. Volume 4 addresses neutronic performance, fabrication technology, and fuel performance and compatibility issues for zirconium-plutonium oxide fuels and aluminum-plutonium metallic fuels. This volumes gives summaries of Volumes 2--4

  13. Effect of tapering after a period of high-volume sprint interval training on running performance and muscular adaptations in moderately trained runners

    DEFF Research Database (Denmark)

    Skovgaard, Casper; Almquist, Nicki Winfield; Kvorning, Thue

    2018-01-01

    The effect of tapering following a period of high-volume sprint interval training (SIT) and a basic volume of aerobic training on performance and muscle adaptations in moderately trained runners was examined. Eleven (8 males, 3 females) runners (maximum oxygen uptake (VO2-max): 56.8±2.9 mL·min(-1...... running test at 90% of vVO2-max to exhaustion (RRT). In addition, a biopsy from m. vastus lateralis was obtained at rest. Performance during RRT was better (P... at 60% of vVO2-max was lower (P

  14. Study of the Utah uranium-milling industry. Volume I. A policy analysis

    International Nuclear Information System (INIS)

    Turley, R.E.

    1980-05-01

    This is the first volume of a two volume study of the Utah Uranium Milling Industry. The study was precipitated by a 1977 report issued by the Western Interstate Nuclear Board entitled Policy Recommendations on Financing Stabilization. Perpetual Surveillance and Maintenance of Uranium Mill Tailings. Volume I of this study is a policy analysis or technology assessment of the uranium milling industry in the state of Utah; specifically, the study addresses issues that deal with the perpetual surveillance, monitoring, and maintenance of uranium tailings piles at the end of uranium milling operations, i.e., following shutdown and decommissioning. Volume II of this report serves somewhat as an appendix. It represents a full description of the uranium industry in the state of Utah, including its history and statements regarding its future. The topics covered in volume I are as follows: today's uranium industry in Utah; management of the industry's characteristic nuclear radiation; uranium mill licensing and regulation; state licensing and regulation of uranium mills; forecast of future milling operations; policy needs relative to perpetual surveillance, monitoring, and maintenance of tailings; policy needs relative to perpetual oversight; economic aspects; state revenue from uranium; and summary with conclusions and recommendations. Appendices, figures and tables are also presented

  15. Are PCI Service Volumes Associated with 30-Day Mortality? A Population-Based Study from Taiwan.

    Science.gov (United States)

    Yu, Tsung-Hsien; Chou, Ying-Yi; Wei, Chung-Jen; Tung, Yu-Chi

    2017-11-09

    The volume-outcome relationship has been discussed for over 30 years; however, the findings are inconsistent. This might be due to the heterogeneity of service volume definitions and categorization methods. This study takes percutaneous coronary intervention (PCI) as an example to examine whether the service volume was associated with PCI 30-day mortality, given different service volume definitions and categorization methods. A population-based, cross-sectional multilevel study was conducted. Two definitions of physician and hospital volume were used: (1) the cumulative PCI volume in a previous year before each PCI; (2) the cumulative PCI volume within the study period. The volume was further treated in three ways: (1) a categorical variable based on the American Heart Association's recommendation; (2) a semi-data-driven categorical variable based on k-means clustering algorithm; and (3) a data-driven categorical variable based on the Generalized Additive Model. The results showed that, after adjusting the patient-, physician-, and hospital-level covariates, physician volume was associated inversely with PCI 30-day mortality, but hospital volume was not, no matter which definitions and categorization methods of service volume were applied. Physician volume is negatively associated with PCI 30-day mortality, but the results might vary because of definition and categorization method.

  16. [Target volume margins for lung cancer: internal target volume/clinical target volume].

    Science.gov (United States)

    Jouin, A; Pourel, N

    2013-10-01

    The aim of this study was to carry out a review of margins that should be used for the delineation of target volumes in lung cancer, with a focus on margins from gross tumour volume (GTV) to clinical target volume (CTV) and internal target volume (ITV) delineation. Our review was based on a PubMed literature search with, as a cornerstone, the 2010 European Organisation for Research and Treatment of Cancer (EORTC) recommandations by De Ruysscher et al. The keywords used for the search were: radiotherapy, lung cancer, clinical target volume, internal target volume. The relevant information was categorized under the following headings: gross tumour volume definition (GTV), CTV-GTV margin (first tumoural CTV then nodal CTV definition), in field versus elective nodal irradiation, metabolic imaging role through the input of the PET scanner for tumour target volume and limitations of PET-CT imaging for nodal target volume definition, postoperative radiotherapy target volume definition, delineation of target volumes after induction chemotherapy; then the internal target volume is specified as well as tumoural mobility for lung cancer and respiratory gating techniques. Finally, a chapter is dedicated to planning target volume definition and another to small cell lung cancer. For each heading, the most relevant and recent clinical trials and publications are mentioned. Copyright © 2013. Published by Elsevier SAS.

  17. Time varying, multivariate volume data reduction

    Energy Technology Data Exchange (ETDEWEB)

    Ahrens, James P [Los Alamos National Laboratory; Fout, Nathaniel [UC DAVIS; Ma, Kwan - Liu [UC DAVIS

    2010-01-01

    Large-scale supercomputing is revolutionizing the way science is conducted. A growing challenge, however, is understanding the massive quantities of data produced by large-scale simulations. The data, typically time-varying, multivariate, and volumetric, can occupy from hundreds of gigabytes to several terabytes of storage space. Transferring and processing volume data of such sizes is prohibitively expensive and resource intensive. Although it may not be possible to entirely alleviate these problems, data compression should be considered as part of a viable solution, especially when the primary means of data analysis is volume rendering. In this paper we present our study of multivariate compression, which exploits correlations among related variables, for volume rendering. Two configurations for multidimensional compression based on vector quantization are examined. We emphasize quality reconstruction and interactive rendering, which leads us to a solution using graphics hardware to perform on-the-fly decompression during rendering. In this paper we present a solution which addresses the need for data reduction in large supercomputing environments where data resulting from simulations occupies tremendous amounts of storage. Our solution employs a lossy encoding scheme to acrueve data reduction with several options in terms of rate-distortion behavior. We focus on encoding of multiple variables together, with optional compression in space and time. The compressed volumes can be rendered directly with commodity graphics cards at interactive frame rates and rendering quality similar to that of static volume renderers. Compression results using a multivariate time-varying data set indicate that encoding multiple variables results in acceptable performance in the case of spatial and temporal encoding as compared to independent compression of variables. The relative performance of spatial vs. temporal compression is data dependent, although temporal compression has the

  18. Plan for studies of subsurface radionuclide migration at the Radioactive Waste Management Complex of the Idaho National Engineering Laboratory. Volume 1 of 2

    International Nuclear Information System (INIS)

    1983-11-01

    This document describes planned studies of subsurface radionuclide migration at the Radioactive Waste Management Complex of the Idaho National Engineering Laboratory. A plan is provided for each proposed study. The rational for arriving at the list of proposed studies is also presented. This document consists of two volumes. In the first volume, Sections 1 through 5 contain the introduction, the objectives of the proposed studies, and background information. The discussion is not comprehensive in detail; documents are referenced that discuss the background material in greater detail. Sections 6 through 9 identify and select the group of studies to be performed and discuss the peer review process. The second volume contains Appendices A and B, which present the assignment of responsibilities and the detailed plans, schedules, and costs for the proposed program

  19. Quantifying Uncertainty in Soil Volume Estimates

    International Nuclear Information System (INIS)

    Roos, A.D.; Hays, D.C.; Johnson, R.L.; Durham, L.A.; Winters, M.

    2009-01-01

    Proper planning and design for remediating contaminated environmental media require an adequate understanding of the types of contaminants and the lateral and vertical extent of contamination. In the case of contaminated soils, this generally takes the form of volume estimates that are prepared as part of a Feasibility Study for Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) sites and/or as part of the remedial design. These estimates are typically single values representing what is believed to be the most likely volume of contaminated soil present at the site. These single-value estimates, however, do not convey the level of confidence associated with the estimates. Unfortunately, the experience has been that pre-remediation soil volume estimates often significantly underestimate the actual volume of contaminated soils that are encountered during the course of remediation. This underestimation has significant implications, both technically (e.g., inappropriate remedial designs) and programmatically (e.g., establishing technically defensible budget and schedule baselines). Argonne National Laboratory (Argonne) has developed a joint Bayesian/geostatistical methodology for estimating contaminated soil volumes based on sampling results, that also provides upper and lower probabilistic bounds on those volumes. This paper evaluates the performance of this method in a retrospective study that compares volume estimates derived using this technique with actual excavated soil volumes for select Formerly Utilized Sites Remedial Action Program (FUSRAP) Maywood properties that have completed remedial action by the U.S. Army Corps of Engineers (USACE) New York District. (authors)

  20. FY 93 thermal loading systems study final report: Volume 1. Revision 1

    International Nuclear Information System (INIS)

    Saterlie, S.F.; Thomson, B.H.

    1994-01-01

    The ability to meet the overall performance requirements for the proposed Mined Geology Disposal System at Yucca Mountain, Nevada requires the two major subsystem (natural barriers and engineered barriers) to positively contribute to containment and radionuclide isolation. In addition to the postclosure performance the proposed repository must meet preclosure requirements of safety, retrievability, and operability. Cost and schedule were also considered. The thermal loading strategy chosen may significantly affect both the postclosure and preclosure performance of the proposed repository. Although the current Site Characterization Plan reference case is 57 kilowatts (kW)/acre, other thermal loading strategies (different areal mass loadings) have been proposed which possess both advantages and disadvantages. The objectives of the FY 1993 Thermal Loading Study were to (1) place bounds on the thermal loading which would establish the loading regime that is ''too hot'' and the loading regime that is ''too cold'', to (2) ''grade'' or evaluate the performance, as a function of thermal loading, of the repository to contain high level wastes against performance criteria and to (3) evaluate the performance of the various options with respect to cost, safety, and operability. Additionally, the effort was to (4) identify important uncertainties that need to be resolved by tests and/or analyses in order to complete a performance assessment on the effects of thermal loading. The FY 1993 Thermal Loading Study was conducted from December 1, 1992 to December 30, 1993 and this final report provides the findings of the study. Volume 1 contains the Introduction; Performance requirements; Input and assumptions; Near-field thermal analysis; Far-field thermal analysis; Cost analysis; Other considerations; System analysis; Additional thermal analysis; and Conclusions and recommendations. 71 refs., 54 figs

  1. Extended performance electric propulsion power processor design study. Volume 2: Technical summary

    Science.gov (United States)

    Biess, J. J.; Inouye, L. Y.; Schoenfeld, A. D.

    1977-01-01

    Electric propulsion power processor technology has processed during the past decade to the point that it is considered ready for application. Several power processor design concepts were evaluated and compared. Emphasis was placed on a 30 cm ion thruster power processor with a beam power rating supply of 2.2KW to 10KW for the main propulsion power stage. Extension in power processor performance were defined and were designed in sufficient detail to determine efficiency, component weight, part count, reliability and thermal control. A detail design was performed on a microprocessor as the thyristor power processor controller. A reliability analysis was performed to evaluate the effect of the control electronics redesign. Preliminary electrical design, mechanical design and thermal analysis were performed on a 6KW power transformer for the beam supply. Bi-Mod mechanical, structural and thermal control configurations were evaluated for the power processor and preliminary estimates of mechanical weight were determined.

  2. The cerebrovascular structure and brain tissue volume: a comparative study between beagle dogs and mongrel dogs

    International Nuclear Information System (INIS)

    Liu Sheng; Shi Haibin; Hu Weixing; Zu Qingquan; Lu Shanshan; Xu Xiaoquan; Sun Lei; Li Linsun

    2011-01-01

    Objective: To compare the differences of cerebrovascular structure and brain tissue volume between beagle and mongrel dogs by using angiography and MR scanning. Methods: A total of 40 dogs, including 20 beagle dogs (beagle group) and 20 mongrel dogs (mongrel group), were enrolled in this study. Under general anesthesia, all dogs were examined with cerebral angiography and MR scanning. The cerebrovascular structure was evaluated with angiography via selective catheterization of aortic arch, bilateral external cerebral arteries (ECA), maxillary arteries, internal cerebral arteries (ICA) and vertebral arteries separately. The diameters of the ICA, middle cerebral artery (MCA), rostral cerebral artery (RCA), the anastomosis channel ICA and ECA, and basilar artery (BA) were measured at the similar point of each dog. Meanwhile the volumes of the brain tissue were calculated in coronal T2 view of MR scanning. The statistical analysis was performed among the weight of dogs, the diameter of arteries and the volume of brain tissue. The differences in the diameters and brain tissue volume were compared between the two groups. Results: No obvious variations in the cerebrovascular structure and brain tissue volume were found in these dogs. One mongrel dog was excluded from this study because of the severe stenosis of ICA. The mean weight of 20 beagle dogs and 19 mongrel dogs was (12.81±1.29) kg and (12.85±1.12) kg, respectively. The diameters of the ICA, MCA, RCA, the anastomosis channel between ICA and ECA and BA in beagle group were (1.26±0.07) mm, (0.90±0.05) mm, (0.58±0.07) mm, (0.55±0.07) mm and (0.95±0.06) mm, respectively. These parameters in mongrel group were (1.27±0.07) mm, (0.92±0.05) mm, (0.59±0.06) mm, (0.67±0.07) mm and (0.94±0.05) mm, respectively. The volume of brain in two groups was (76232.33±5018.51) mm 3 and (71863.96±4626.87) mm 3 , respectively. There were no obvious correlation among the body weight, the cerebrovascular diameters and brain

  3. Risk adjustment for case mix and the effect of surgeon volume on morbidity.

    Science.gov (United States)

    Maas, Matthew B; Jaff, Michael R; Rordorf, Guy A

    2013-06-01

    Retrospective studies of large administrative databases have shown higher mortality for procedures performed by low-volume surgeons, but the adequacy of risk adjustment in those studies is in doubt. To determine whether the relationship between surgeon volume and outcomes is an artifact of case mix using a prospective sample of carotid endarterectomy cases. Observational cohort study from January 1, 2008, through December 31, 2010, with preoperative, immediate postoperative, and 30-day postoperative assessments acquired by independent monitors. Urban, tertiary academic medical center. All 841 patients who underwent carotid endarterectomy performed by a vascular surgeon or cerebrovascular neurosurgeon at the institution. Carotid endarterectomy without another concurrent surgery. Stroke, death, and other surgical complications occurring within 30 days of surgery along with other case data. A low-volume surgeon performed 40 or fewer cases per year. Variables used in a comparison administrative database study, as well as variables identified by our univariate analysis, were used for adjusted analyses to assess for an association between low-volume surgeons and the rate of stroke and death as well as other complications. RESULTS The rate of stroke and death was 6.9% for low-volume surgeons and 2.0% for high-volume surgeons (P = .001). Complications were similarly higher (13.4% vs 7.2%, P = .008). Low-volume surgeons performed more nonelective cases. Low-volume surgeons were significantly associated with stroke and death in the unadjusted analysis as well as after adjustment with variables used in the administrative database study (odds ratio, 3.61; 95% CI, 1.70-7.67, and odds ratio, 3.68; 95% CI, 1.72-7.89, respectively). However, adjusting for the significant disparity of American Society of Anesthesiologists Physical Status classification in case mix eliminated the effect of surgeon volume on the rate of stroke and death (odds ratio, 1.65; 95% CI, 0.59-4.64) and other

  4. The impact of environmental conditions on human performance: A handbood of environmental exposures. Volume 1

    International Nuclear Information System (INIS)

    Echeverria, D.; Barnes, V.; Bittner, A.

    1994-09-01

    A comprehensive review of the technical literature was conducted regarding the impact of environmental conditions on hyman performance applicable to nuclear power plant workers. The environmental conditions considered were vibration, noise, heat, cold, and light. Research staff identified potential human performance deficits (e.g., decreased dexterity, impaired vision, hearing loss, memory deficiency) along a continuum of increasing occupational exposure, ranging from exposures that result in no deficit to exposures that resulted in significant performance problems. Specific deficits were included in the report if there was sound scientific evidence that environmental exposure resulted in those performance deficits. The levels associated with each deficit were then compared to the protection afforded by existing occupational exposure standards. Volume 1 is a handbook for use by NRC inspectors to help them determine the impact of specific environmental conditions on licensee personnel performance. it discusses the units used to measure each condition, discusses the effects of the condition on task performance, presents an example of the assessment of each condition in a nuclear power plant, and discusses potential methods for reducing the effects of

  5. BPACK -- A computer model package for boiler reburning/co-firing performance evaluations. User`s manual, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Wu, K.T.; Li, B.; Payne, R.

    1992-06-01

    This manual presents and describes a package of computer models uniquely developed for boiler thermal performance and emissions evaluations by the Energy and Environmental Research Corporation. The model package permits boiler heat transfer, fuels combustion, and pollutant emissions predictions related to a number of practical boiler operations such as fuel-switching, fuels co-firing, and reburning NO{sub x} reductions. The models are adaptable to most boiler/combustor designs and can handle burner fuels in solid, liquid, gaseous, and slurried forms. The models are also capable of performing predictions for combustion applications involving gaseous-fuel reburning, and co-firing of solid/gas, liquid/gas, gas/gas, slurry/gas fuels. The model package is conveniently named as BPACK (Boiler Package) and consists of six computer codes, of which three of them are main computational codes and the other three are input codes. The three main codes are: (a) a two-dimensional furnace heat-transfer and combustion code: (b) a detailed chemical-kinetics code; and (c) a boiler convective passage code. This user`s manual presents the computer model package in two volumes. Volume 1 describes in detail a number of topics which are of general users` interest, including the physical and chemical basis of the models, a complete description of the model applicability, options, input/output, and the default inputs. Volume 2 contains a detailed record of the worked examples to assist users in applying the models, and to illustrate the versatility of the codes.

  6. Feasibility and performance of novel software to quantify metabolically active volumes and 3D partial volume corrected SUV and metabolic volumetric products of spinal bone marrow metastases on 18F-FDG-PET/CT.

    Science.gov (United States)

    Torigian, Drew A; Lopez, Rosa Fernandez; Alapati, Sridevi; Bodapati, Geetha; Hofheinz, Frank; van den Hoff, Joerg; Saboury, Babak; Alavi, Abass

    2011-01-01

    Our aim was to assess feasibility and performance of novel semi-automated image analysis software called ROVER to quantify metabolically active volume (MAV), maximum standardized uptake value-maximum (SUV(max)), 3D partial volume corrected mean SUV (cSUV(mean)), and 3D partial volume corrected mean MVP (cMVP(mean)) of spinal bone marrow metastases on fluorine-18 fluorodeoxyglucose-positron emission tomography/computerized tomography ((18)F-FDG-PET/CT). We retrospectively studied 16 subjects with 31 spinal metastases on FDG-PET/CT and MRI. Manual and ROVER determinations of lesional MAV and SUV(max), and repeated ROVER measurements of MAV, SUV(max), cSUV(mean) and cMVP(mean) were made. Bland-Altman and correlation analyses were performed to assess reproducibility and agreement. Our results showed that analyses of repeated ROVER measurements revealed MAV mean difference (D)=-0.03±0.53cc (95% CI(-0.22, 0.16)), lower limit of agreement (LLOA)=-1.07cc, and upper limit of agreement (ULOA)=1.01cc; SUV(max) D=0.00±0.00 with LOAs=0.00; cSUV(mean) D=-0.01±0.39 (95% CI(-0.15, 0.13)), LLOA=-0.76, and ULOA=0.75; cMVP(mean) D=-0.52±4.78cc (95% CI(-2.23, 1.23)), LLOA=-9.89cc, and ULOA=8.86cc. Comparisons between ROVER and manual measurements revealed volume D= -0.39±1.37cc (95% CI (-0.89, 0.11)), LLOA=-3.08cc, and ULOA=2.30cc; SUV(max) D=0.00±0.00 with LOAs=0.00. Mean percent increase in lesional SUV(mean) and MVP(mean) following partial volume correction using ROVER was 84.25±36.00% and 84.45±35.94% , respectively. In conclusion, it is feasible to estimate MAV, SUV(max), cSUV(mean), and cMVP(mean) of spinal bone marrow metastases from (18)F-FDG-PET/CT quickly and easily with good reproducibility via ROVER software. Partial volume correction is imperative, as uncorrected SUV(mean) and MVP(mean) are significantly underestimated, even for large lesions. This novel approach has great potential for practical, accurate, and precise combined structural-functional PET

  7. Detection of EEG electrodes in brain volumes.

    Science.gov (United States)

    Graffigna, Juan P; Gómez, M Eugenia; Bustos, José J

    2010-01-01

    This paper presents a method to detect 128 EEG electrodes in image study and to merge with the Nuclear Magnetic Resonance volume for better diagnosis. First we propose three hypotheses to define a specific acquisition protocol in order to recognize the electrodes and to avoid distortions in the image. In the second instance we describe a method for segmenting the electrodes. Finally, registration is performed between volume of the electrodes and NMR.

  8. Impact of partial-volume correction in oncological PET studies. A systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cysouw, Matthijs C.F.; Kramer, Gerbrand M.; Hoekstra, Otto S. [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Schoonmade, Linda J. [VU University Medical Centre, Department of Medical Library, Amsterdam (Netherlands); Boellaard, Ronald [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); University Medical Centre Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Vet, Henrica C.W. de [VU University Medical Centre, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands)

    2017-11-15

    Positron-emission tomography can be useful in oncology for diagnosis, (re)staging, determining prognosis, and response assessment. However, partial-volume effects hamper accurate quantification of lesions <2-3 x the PET system's spatial resolution, and the clinical impact of this is not evident. This systematic review provides an up-to-date overview of studies investigating the impact of partial-volume correction (PVC) in oncological PET studies. We searched in PubMed and Embase databases according to the PRISMA statement, including studies from inception till May 9, 2016. Two reviewers independently screened all abstracts and eligible full-text articles and performed quality assessment according to QUADAS-2 and QUIPS criteria. For a set of similar diagnostic studies, we statistically pooled the results using bivariate meta-regression. Thirty-one studies were eligible for inclusion. Overall, study quality was good. For diagnosis and nodal staging, PVC yielded a strong trend of increased sensitivity at expense of specificity. Meta-analysis of six studies investigating diagnosis of pulmonary nodules (679 lesions) showed no significant change in diagnostic accuracy after PVC (p = 0.222). Prognostication was not improved for non-small cell lung cancer and esophageal cancer, whereas it did improve for head and neck cancer. Response assessment was not improved by PVC for (locally advanced) breast cancer or rectal cancer, and it worsened in metastatic colorectal cancer. The accumulated evidence to date does not support routine application of PVC in standard clinical PET practice. Consensus on the preferred PVC methodology in oncological PET should be reached. Partial-volume-corrected data should be used as adjuncts to, but not yet replacement for, uncorrected data. (orig.)

  9. Intranasal localizability of odorants: influence of stimulus volume.

    Science.gov (United States)

    Frasnelli, J; Hummel, T; Berg, J; Huang, G; Doty, R L

    2011-05-01

    When an odorant is presented to one side of the nose and air to the other, the ability to localize which side received the odorant depends upon trigeminal nerve stimulation. It has been shown that performance on this lateralization task increases as stimulus concentration increases. In this study, we determined the influences of stimulus volume and sex on the ability to localize each of 8 odorants presented at neat concentrations: anethole, geraniol, limonene, linalool, menthol, methyl salicylate, phenyl ethanol, and vanillin. At a low stimulus volume (11 mL), only menthol was localized at an above-chance level. At a high stimulus volume (21 mL), above-chance localization occurred for all odorants except vanillin. Women were significantly better than men in localizing menthol. Stimuli rated as most intense were those that were most readily localized. The detection performance measures, as well as rated intensity values, significantly correlated with earlier findings of the trigeminal detectability of odorants presented to anosmic and normosmic subjects. This study suggests that differences in stimulus volume may explain some discrepant findings within the trigeminal chemosensory literature and supports the concept that vanillin may be a "relatively pure" olfactory stimulus.

  10. Phantom study of PET/CT guided delineation of radiation therapy volume

    International Nuclear Information System (INIS)

    Lin Lin; Zheng Rong; Wang Yibin; Geng Jianhua; Wu Ning; Zhao Ping

    2012-01-01

    Objective: To propose a model-based method for calculating the threshold in GTV determination by 18 F-FDG PET in a phantom study. Methods: A phantom was constructed of a 9 L cylindrical tank.Glass spheres with volumes ranging from 0.5 to 16 ml (0.5, 1, 2, 4, 8 and 16 ml) were suspended within the tank. The six spheres were filled with an identical concentration of FDG (203.5 MBq/L) and suspended within 3 different background baths of FDG (6.179, 16.021, 0 MBq/L) solutions, creating 3 target-to-background ratios of 32.96 : 1, 12.69 : 1 and target to zero background. A linear regressive function was constructed which represented the relationship between the threshold and the average activity concentration of the target. A 40% of maximum intensity threshold and the linear regressive function method were applied to define the spheres filled with 18 F-FDG. The volume differences between the two methods and the true volumes of the spheres were compared with t-test. Results: The linear regressive function model was derived as:threshold =(mean target concentration + 2.6227)/1.9752. The results indicated that a smaller deviation occurred when the function was utilized to estimate the volumes of the phantoms as compared to the 40% of maximum intensity threshold method, but there were no significant differences between them (t=0.306, P>0.05). The effect of the linear regressive function on volume was such that when the phantom sphere volumes were ≥ 1 ml, the average deviation between the defined volumes and the true volumes of phantoms was 1.01%; but when the phantom sphere volume was 0.5 ml, the average deviation was 9.53%. When the 40% of maximum intensity threshold method was applied to define the phantom spheres of volume ≥2 ml, the average deviation between the defined volumes and the true volumes of phantoms was -4.62%; but, the average deviation of that was 19.9% when the volumes of spheres were 0.5 and 1 ml. When the linear regressive function was applied to

  11. VOLUME STUDY WITH HIGH DENSITY OF PARTICLES BASED ON CONTOUR AND CORRELATION IMAGE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Tatyana Yu. Nikolaeva

    2014-11-01

    Full Text Available The subject of study is the techniques of particle statistics evaluation, in particular, processing methods of particle images obtained by coherent illumination. This paper considers the problem of recognition and statistical accounting for individual images of small scattering particles in an arbitrary section of the volume in case of high concentrations. For automatic recognition of focused particles images, a special algorithm for statistical analysis based on contouring and thresholding was used. By means of the mathematical formalism of the scalar diffraction theory, coherent images of the particles formed by the optical system with high numerical aperture were simulated. Numerical testing of the method proposed for the cases of different concentrations and distributions of particles in the volume was performed. As a result, distributions of density and mass fraction of the particles were obtained, and the efficiency of the method in case of different concentrations of particles was evaluated. At high concentrations, the effect of coherent superposition of the particles from the adjacent planes strengthens, which makes it difficult to recognize images of particles using the algorithm considered in the paper. In this case, we propose to supplement the method with calculating the cross-correlation function of particle images from adjacent segments of the volume, and evaluating the ratio between the height of the correlation peak and the height of the function pedestal in the case of different distribution characters. The method of statistical accounting of particles considered in this paper is of practical importance in the study of volume with particles of different nature, for example, in problems of biology and oceanography. Effective work in the regime of high concentrations expands the limits of applicability of these methods for practically important cases and helps to optimize determination time of the distribution character and

  12. Chemical sensitive interfacial free volume studies of nanophase Al-rich alloys

    International Nuclear Information System (INIS)

    Lechner, W.; Puff, W.; Wuerschum, R.; Wilde, G.

    2006-01-01

    Full text: Al-based nanocrystalline alloys have attracted substantial interest due to their outstanding mechanical properties. These alloys can be obtained by crystallization of melt-spun amorphous precursors or by grain refinement upon repeated cold-rolling of elemental layers. For both synthesis routes, the nanocrystallization process is sensitively affected by interfacial chemistry and free volumes. In order to contribute to an atomistic understanding of the interfacial structure and processes during nanocrystallization, the present work deals with studies of interfacial free volumes by means of positron-annihilation-spectroscopy. In addition to positron lifetime spectroscopy which yields information on the size of free volumes, coincident Doppler broadening of the positron-electron annihilation photons is applied as novel technique for studying the chemistry of interfaces in nanophase materials on an atomistic scale. Al-rich alloys of the above mentioned synthesis routes were studied in this work. (author)

  13. Multi-site, multi-country evaluation of analytical and operational performance of a low-mid volume chemiluminescent immunoassay analyzer.

    Science.gov (United States)

    De Keijzer, M H; Perkins, S; Motta, V; Morelli, D; Cristol, J P; Dupuy, A M; Hong, Y; Watanabe, S; Waerdt, C; Grunewald, R W

    2009-01-01

    A new automated immunoassay low-mid volume (beta-hCG, BNP, and CK-MB) and the time required to complete workloads of 50 and 100 tests with a mixture of 75% routine tests and 25% stat tests was also evaluated. Total precision was typically market and in use for an existing high volume immunoassay system. Stat turn around times were consistent with the fixed analytical time of 15.6 minutes and met the expectations of the laboratories. Measured test throughput ranged from 47 - 54 tests per hour and demonstrated that the analyzer was fit for the intended purpose of supporting a laboratory that performs suitable for use.

  14. Efficacy and safety of tolvaptan in heart failure patients with volume overload despite the standard treatment with conventional diuretics: a phase III, randomized, double-blind, placebo-controlled study (QUEST study).

    Science.gov (United States)

    Matsuzaki, Masunori; Hori, Masatsugu; Izumi, Tohru; Fukunami, Masatake

    2011-12-01

    Diuretics are recommended to treat volume overload with heart failure (HF), however, they may cause serum electrolyte imbalance, limiting their use. Moreover, patients with advanced HF could poorly respond to these diuretics. In this study, we evaluated the efficacy and safety of Tolvaptan, a competitive vasopressin V2-receptor antagonist developed as a new drug to treat volume overload in HF patients. A phase III, multicenter, randomized, double-blind, placebo-controlled parallel study was performed to assess the efficacy and safety of tolvaptan in treating HF patients with volume overload despite the use of conventional diuretics. One hundred and ten patients were randomly assigned to receive either placebo or 15 mg/day tolvaptan for 7 consecutive days. Compared with placebo, tolvaptan administered for 7 days significantly reduced body weight and improved symptoms associated with volume overload. The safety profile of tolvaptan was considered acceptable for clinical use with minimal adverse effects. Tolvaptan reduced volume overload and improved congestive symptoms associated with HF by a potent water diuresis (aquaresis).

  15. Determination of blood volume by pulse CO-oximetry

    International Nuclear Information System (INIS)

    Lalande, S; Kelsey, J W; Joyner, M J; Johnson, B D

    2012-01-01

    The objective of this study was to determine whether changes in carboxyhaemoglobin (COHb) saturation following carbon monoxide (CO) rebreathing can be accurately detected by pulse CO-oximetry in order to determine blood volume. Noninvasive measurements of carboxyhaemoglobin saturation (SpCO) were continuously monitored by pulse CO-oximetry before, during and following 2 min of CO rebreathing. Reproducibility and accuracy of noninvasive blood volume measurements were determined in 16 healthy non-smoking individuals (15 males, age: 28 ± 2 years, body mass index: 25.4 ± 0.6 kg m −2 ) through comparison with blood volume measurements calculated from invasive measurements of COHb saturation. The coefficient of variation for noninvasive blood volume measurements performed on separate days was 15.1% which decreases to 9.1% when measurements were performed on the same day. Changes in COHb saturation and SpCO following CO rebreathing were strongly correlated (r = 0.90, p < 0.01), resulting in a significant correlation between invasive and noninvasive blood volume measurements (r = 0.83, p = 0.02). Changes in SpCO following CO rebreathing can be accurately detected by pulse CO-oximetry, which could potentially provide a simplified, convenient and reproducible method to rapidly determine blood volume in healthy individuals

  16. Optimal Solution Volume for Luminal Preservation: A Preclinical Study in Porcine Intestinal Preservation.

    Science.gov (United States)

    Oltean, M; Papurica, M; Jiga, L; Hoinoiu, B; Glameanu, C; Bresler, A; Patrut, G; Grigorie, R; Ionac, M; Hellström, M

    2016-03-01

    Rodent studies suggest that luminal solutions alleviate the mucosal injury and prolong intestinal preservation but concerns exist that excessive volumes of luminal fluid may promote tissue edema. Differences in size, structure, and metabolism between rats and humans require studies in large animals before clinical use. Intestinal procurement was performed in 7 pigs. After perfusion with histidine-tryptophan-ketoglutarate (HTK), 40-cm-long segments were cut and filled with 13.5% polyethylene glycol (PEG) 3350 solution as follows: V0 (controls, none), V1 (0.5 mL/cm), V2 (1 mL/cm), V3 (1.5 mL/cm), and V4 (2 mL/cm). Tissue and luminal solutions were sampled after 8, 14, and 24 hours of cold storage (CS). Preservation injury (Chiu score), the apical membrane (ZO-1, brush-border maltase activity), and the electrolyte content in the luminal solution were studied. In control intestines, 8-hour CS in HTK solution resulted in minimal mucosal changes (grade 1) that progressed to significant subepithelial edema (grade 3) by 24 hours. During this time, a gradual loss in ZO-1 was recorded, whereas maltase activity remained unaltered. Moreover, variable degrees of submucosal edema were observed. Luminal introduction of high volumes (2 mL/mL) of PEG solution accelerated the development of the subepithelial edema and submucosal edema, leading to worse histology. However, ZO-1 was preserved better over time than in control intestines (no luminal solution). Maltase activity was reduced in intestines receiving luminal preservation. Luminal sodium content decreased in time and did not differ between groups. This PEG solution protects the apical membrane and the tight-junction proteins but may favor water absorption and tissue (submucosal) edema, and luminal volumes >2 mL/cm may result in worse intestinal morphology. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Plan for studies of subsurface radionuclide migration at the Radioactive Waste Management Complex of the Idaho National Engineering Laboratory. Volume 2 of 2. Appendices

    International Nuclear Information System (INIS)

    1983-11-01

    This document describes planned studies of subsurface radionuclide migration at the Radioactive Waste Management Complex of the Idaho National Engineering Laboratory. A plan is provided for each proposed study. The rational for arriving at the list of proposed studies is also presented. This document consists of two volumes. In the first volume, Sections 1 through 5 contain the introduction, the objectives of the proposed studies, and background information. The discussion is not comprehensive in detail; documents are referenced that discuss the background material in greater detail. Sections 6 through 9 identify and select the group of studies to be performed and discuss the peer review process. The second volume contains Appendices A and B, which present the assignment of responsibilities and the detailed plans, schedules, and costs for the proposed program

  18. A Curriculum Activities Guide to Water Pollution and Environmental Studies, Volume II - Appendices.

    Science.gov (United States)

    Hershey, John T., Ed.; And Others

    This publication, Volume II of a two volume set of water pollution studies, contains seven appendices which support the studies. Appendix 1, Water Quality Parameters, consolidates the technical aspects of water quality including chemical, biological, computer program, and equipment information. Appendix 2, Implementation, outlines techniques…

  19. Diagnostic imaging procedure volume in the United States

    International Nuclear Information System (INIS)

    Johnson, J.L.; Abernathy, D.L.

    1983-01-01

    Comprehensive data on 1979 and 1980 diagnostic imaging procedure volume were collected from a stratified random sample of U.S. short-term general-care hospitals and private practices of radiologists, cardiologists, obstetricians/gynecologists, orthopedic surgeons, and neurologists/neurosurgeons. Approximately 181 million imaging procedures (within the study scope) were performed in 1980. Despite the rapidly increasing use of newer imaging methods, plain film radiography (140.3 million procedures) and contrast studies (22.9 million procedures) continue to comprise the vast majority of diagnostic imaging volume. Ultrasound, computed tomography, nuclear medicine, and special procedures make up less than 10% of total diagnostic imaging procedures. Comparison of the data from this study with data from an earlier study indicates that imaging procedure volume in hospitals expanded at an annual growth rate of almost 8% from 1973 to 1980

  20. Breadth versus volume: Neurology outpatient clinic cases in medical education.

    Science.gov (United States)

    Albert, Dara V; Blood, Angela D; Park, Yoon Soo; Brorson, James R; Lukas, Rimas V

    2016-06-01

    This study examined how volume in certain patient case types and breadth across patient case types in the outpatient clinic setting are related to Neurology Clerkship student performance. Case logs from the outpatient clinic experience of 486 students from The University of Chicago Pritzker School of Medicine, USA, participating in the 4week Neurology Clerkship from July 2008 to June 2013 were reviewed. A total of 12,381 patient encounters were logged and then classified into 13 diagnostic categories. How volume of cases within categories and the breadth of cases across categories relate to the National Board of Medical Examiners Clinical Subject Examination for Neurology and a Neurology Clerkship Objective Structured Clinical Examination was analyzed. Volume of cases was significantly correlated with the National Board of Medical Examiners Clinical Subject Examination for Neurology (r=.290, pNeurology (r=.231, p=.017), however was not significantly correlated with any component of the Objective Structured Clinical Examination. Volume of cases correlated with higher performance on measures of specialty knowledge and clinical skill. Fewer relationships emerged correlating breadth of cases and performance on the same measures. This study provides guidance to educators who must decide how much emphasis to place on volume versus breadth of cases in outpatient clinic learning experiences. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Increased putamen volume in adults with autism spectrum disorder

    Directory of Open Access Journals (Sweden)

    Wataru eSato

    2014-11-01

    Full Text Available Basal ganglia (BG abnormalities are implicated in the pathophysiology of autism spectrum disorder (ASD. However, studies measuring the volume of the entire BG in individuals with ASD have reported discrepant findings, and no study conducted volume measurement of the entire substructures of the BG (the caudate, putamen, nucleus accumbens, and globus pallidus in individuals with ASD. We delineated the BG substructures and measured their volumes in 29 adults with ASD without intellectual disabilities and 29 age- and gender-matched typically developed adult controls. We acquired T1-weighted anatomical images and performed semi-automated delineation and volume measurements of the above-mentioned subregions. Total cerebral volumes, sex, and ages were partialed out. Compared with controls, the putamen was significantly larger in the ASD group. The increased volume of the putamen found in high-functioning adults with ASD suggests that structural or histological abnormalities of the putamen may underlie the pathologies of ASD such as repetitive and stereotyped behaviors and impaired social interactions.

  2. Performance analysis and experimental study of heat-source tower solution regeneration

    International Nuclear Information System (INIS)

    Liang, Caihua; Wen, Xiantai; Liu, Chengxing; Zhang, Xiaosong

    2014-01-01

    Highlights: • Theoretical analysis is performed on the characteristics of heat-source tower. • Experimental study is performed on various rules of the solution regeneration rate. • The characteristics of solution regeneration vary widely with different demands. • Results are useful for optimizing the process of solution regeneration. - Abstract: By analyzing similarities and difference between the solution regeneration of a heat-source tower and desiccant solution regeneration, this paper points out that solution regeneration of a heat-source tower has the characteristics of small demands and that a regeneration rate is susceptible to outdoor ambient environments. A theoretical analysis is performed on the characteristics of a heat-source tower solution in different outdoor environments and different regeneration modes, and an experimental study is performed on variation rules of the solution regeneration rate of a cross-flow heat-source tower under different inlet parameters and operating parameters. The experimental results show that: in the operating regeneration mode, as the air volume was increased from 123 m 3 h −1 to 550 m 3 h −1 , the system heat transfer amount increased from 0.42 kW to 0.78 kW, and the regeneration rate increased from 0.03 g s −1 to 0.19 g s −1 . Increasing the solution flow may increase the system heat transfer amount; however, the regeneration rate decreased to a certain extent. In the regeneration mode when the system is idle, as the air volume was increased from 136 m 3 h −1 to 541 m 3 h −1 , the regeneration rate increased from 0.03 g s −1 to 0.1 g s −1 . The regeneration rate almost remained unchanged around 0.07 g s −1 as the solution flow is increased. In the regeneration mode with auxiliary heat when the system is idle, increasing the air volume and increasing the solution flow required more auxiliary heat, thereby improving the solution regeneration rate. As the auxiliary heat was increased from 0.33 k

  3. October 2015 Phoenix pulmonary journal club: lung volume reduction

    Directory of Open Access Journals (Sweden)

    Mathew M

    2015-11-01

    Full Text Available No abstract available. Article truncated at 150 words. The October 2015 pulmonary journal club focused on the review of older studies evaluating lung volume reduction surgery and how this has transitioned toward the development of non-surgical modes of lung volume reduction. The physiology behind dyspnea in chronic obstructive pulmonary disease (COPD is a complex process. One of the proposed mechanisms has been hyperinflation associated with air trapping. In the mid 1990s studies by Cooper and Peterson (1 offered a promising approach in which lung volume reduction (LVR could improve ventilatory mechanics and improve dyspnea. As the procedure gained more popularity, additional larger scale trials were performed to support its validity. We reviewed 2 studies looking at lung volume reduction. The first was "The Effect of Lung Volume Reduction Surgery In Patients With Severe Emphysema” (2 . This was a smaller, randomized controlled trial (RCT that looked at 2 groups of 24 patients. Once group received LVR while the ...

  4. Effects of reduced return activated sludge flows and volume on anaerobic zone performance for a septic wastewater biological phosphorus removal system.

    Science.gov (United States)

    Magro, Daniel; Elias, Steven L; Randall, Andrew Amis

    2005-01-01

    Enhanced biological phosphorous removal (EBPR) performance was found to be adequate with reduced return-activated sludge (RAS) flows (50% of available RAS) to the anaerobic tank and smaller-than-typical anaerobic zone volume (1.08 hours hydraulic retention time [HRT]). Three identical parallel biological nutrient removal pilot plants were fed with strong, highly fermented (160 mg/L volatile fatty acids [VFAs]), domestic and industrial wastewater from a full-scale wastewater treatment facility. The pilot plants were operated at 100, 50, 40, and 25% RAS (percent of available RAS) flows to the anaerobic tank, with the remaining RAS to the anoxic tank. In addition, varying anaerobic HRT (1.08 and 1.5 hours) and increased hydraulic loading (35% increase) were examined. The study was divided into four phases, and the effect of these process variations on EBPR were studied by having one different variable between two identical systems. The most significant conclusion was that returning part of the RAS to the anaerobic zone did not decrease EBPR performance; instead, it changed the location of phosphorous release and uptake. Bringing less RAS to the anaerobic and more to the anoxic tank decreased anaerobic phosphorus release and increased anoxic phosphorus release (or decreased anoxic phosphorus uptake). Equally important is that, with VFA-rich influent wastewater, excessive anaerobic volume was shown to hurt overall phosphorus removal, even when it resulted in increased anaerobic phosphorus release.

  5. Ambient temperature and volume of perihematomal edema in acute intracerebral haemorrhage: the INTERACT1 study.

    Science.gov (United States)

    Zheng, Danni; Arima, Hisatomi; Heeley, Emma; Karpin, Anne; Yang, Jie; Chalmers, John; Anderson, Craig S

    2015-01-01

    As no human data exist, we aimed to determine the relation between ambient temperature and volume of perihematomal 'cerebral' edema in acute spontaneous intracerebral haemorrhage (ICH) among Chinese participants of the pilot phase, Intensive Blood Pressure Reduction in Acute Cerebral Haemorrhage Trial (INTERACT1). INTERACT1 was a multicenter, open, blind outcome assessed, randomized controlled trial of intensive (systolic target ambient temperature (mean, minimum, maximum, and range) on the day of each participant's ICH obtained from China Meteorological Data Sharing Service System were linked to other data including edema volumes. Multivariable regression analyses were performed to evaluate association between ambient temperature and edema volumes. A generalized linear regression model with a generalized estimating equations approach (GEE) was used to assess any association of ambient temperature and change in edema volume over 72 h. A total of 250 of all 384 Chinese participants had complete data that showed positive associations between ambient temperature (mean and minimum temperatures) and edema volumes at each time point over 72 h after hospital admission (all P ambient temperature and perihematomal edema volume in acute spontaneous ICH. © 2014 World Stroke Organization.

  6. Association of Very Low-Volume Practice With Vascular Surgery Outcomes in New York.

    Science.gov (United States)

    Mao, Jialin; Goodney, Philip; Cronenwett, Jack; Sedrakyan, Art

    2017-08-01

    Little research has focused on very low-volume surgery, especially in the context of decreasing vascular surgery volume with the adoption of endovascular procedures. To investigate the existence and outcomes of open abdominal aortic aneurysm repair (OAR) and carotid endarterectomy (CEA) performed by very low-volume surgeons in New York. This cohort study examined inpatient data of patients undergoing elective OAR or CEA from 2000 to 2014 from all New York hospitals. Surgeons who performed 1 or less designated procedure per year on average were considered very low volume, as opposed to higher-volume surgeons. Temporal trends of the existence of very low-volume practice were evaluated. Hierarchical logistic regression was used to compare in-hospital outcomes and health care resource use between patients treated by very low-volume surgeons and higher-volume surgeons for both OAR and CEA, adjusting for patient, surgeon, and hospital characteristics. There were 8781 OAR procedures and 68 896 CEA procedures included in the study. The mean (SD) patient age was 71.7 (8.4) years for OAR and 71.5 (9.1) years for CEA. A total of 614 surgeons performed OAR and 1071 performed CEA in New York during the study period. Of these, 318 (51.8%) and 512 (47.8%), respectively, were very low-volume surgeons. Very low-volume surgeons were less likely to be vascular surgeons. The number and proportion of very low-volume surgeons decreased over years. Compared with patients treated by higher-volume surgeons, those treated by very low-volume surgeons were more likely to have higher in-hospital mortality (odds ratio [OR], 2.09; 95% CI, 1.41-3.08) following OAR and higher risks of postoperative myocardial infarction (OR, 1.83; 95% CI, 1.03-3.26) and stroke (OR, 1.78; 95% CI, 1.21-2.62) following CEA. Patients treated by very low-volume surgeons also had greater health care resource use following both surgeries, including prolonged length of stay (OR, 1.37; 95% CI, 1.11-1.70) following OAR as

  7. Hippocampal and caudate volume reductions in antipsychotic-naive first-episode schizophrenia

    DEFF Research Database (Denmark)

    Ebdrup, Bjørn Hylsebeck; Glenthøj, Birte; Rasmussen, Hans

    2010-01-01

    of a false discovery rate correction (p brain structure volumes. We grouped patients as those with (n = 9) or without (n = 29) any lifetime substance abuse to examine the possible effects of substance abuse. RESULTS: We found......BACKGROUND: Enlarged ventricles and reduced hippocampal volume are consistently found in patients with first-episode schizophrenia. Studies investigating brain structure in antipsychotic-naive patients have generally focused on the striatum. In this study, we examined whether ventricular...... healthy controls by use of a 3-T scanner. We warped the brain images to each other by use of a high-dimensional intersubject registration algorithm. We performed voxel-wise group comparisons with permutation tests. We performed small volume correction for the hippocampus, caudate and ventricles by use...

  8. Increasing fill volume reduces cardiac performance in peritoneal dialysis

    DEFF Research Database (Denmark)

    Ivarsen, Per; Povlsen, Johan V; Jensen, Jens Dam

    2007-01-01

    BACKGROUND: It is generally accepted that peritoneal dialysis (PD) affects systemic haemodynamics less than haemodialysis, but little is known about changes in haemodynamics during PD. It is unknown if increasing PD volume causes changes in cardiovascular haemodynamics possibly increasing...

  9. The ATS Web Page Provides "Tool Boxes" for: Access Opportunities, Performance, Interfaces, Volume, Environments, "Wish List" Entry and Educational Outreach

    Science.gov (United States)

    1999-01-01

    This viewgraph presentation gives an overview of the Access to Space website, including information on the 'tool boxes' available on the website for access opportunities, performance, interfaces, volume, environments, 'wish list' entry, and educational outreach.

  10. ICP curve morphology and intracranial flow-volume changes

    DEFF Research Database (Denmark)

    Unnerbäck, Mårten; Ottesen, Johnny T.; Reinstrup, Peter

    2018-01-01

    proposed to shape the ICP curve. This study tested the hypothesis that the ICP curve correlates to intracranial volume changes. METHODS: Cine phase contrast magnetic resonance imaging (MRI) examinations were performed in neuro-intensive care patients with simultaneous ICP monitoring. The MRI was set......BACKGROUND: The intracranial pressure (ICP) curve with its different peaks has been extensively studied, but the exact physiological mechanisms behind its morphology are still not fully understood. Both intracranial volume change (ΔICV) and transmission of the arterial blood pressure have been...

  11. Use of volume-rendered images in registration of nuclear medicine studies

    International Nuclear Information System (INIS)

    Wallis, J.W.; Miller, T.R.; Hsu, S.S.

    1995-01-01

    A simple operator-guided alignment technique based on volume-rendered images was developed to register tomographic nuclear medicine studies. For each of 2 three-dimensional data sets to be registered, volume-rendered images were generated in 3 orthogonal projections (x,y,z) using the method of maximum-activity projection. Registration was achieved as follows: (a) One of the rendering orientations (e.g. x) was chosen for manipulation; (b) The two dimensional rendering was translated and rotated under operator control to achieve the best alignment as determined by visual assessment; (c) This rotation and translation was then applied to the underlying three-dimensional data set, with updating of the rendered images in each of the orthogonal projections; (d) Another orientation was chosen, and the process repeated. Since manipulation was performed on the small two-dimensional rendered image, feedback was instantaneous. To aid in the visual alignment, difference images and flicker images (toggling between the two data sets) were displayed. Accuracy was assessed by analysis of separate clinical data sets acquired without patient movement. After arbitrary rotation and translation of one of the two data sets, the 2 data sets were registered. Mean registration error was 0.36 pixels, corresponding to a 2.44 mm registration error. Thus, accurate registration can be achieved in under 10 minutes using this simple technique. The accuracy of registration was assessed with use of duplicate SPECT studies originating from separate reconstructions of the data from each of the detectors of a triple-head gamma camera

  12. Abdominal injuries in a low trauma volume hospital--a descriptive study from northern Sweden.

    Science.gov (United States)

    Pekkari, Patrik; Bylund, Per-Olof; Lindgren, Hans; Öman, Mikael

    2014-08-15

    Abdominal injuries occur relatively infrequently during trauma, and they rarely require surgical intervention. In this era of non-operative management of abdominal injuries, surgeons are seldom exposed to these patients. Consequently, surgeons may misinterpret the mechanism of injury, underestimate symptoms and radiologic findings, and delay definite treatment. Here, we determined the incidence, diagnosis, and treatment of traumatic abdominal injuries at our hospital to provide a basis for identifying potential hazards in non-operative management of patients with these injuries in a low trauma volume hospital. This retrospective study included prehospital and in-hospital assessments of 110 patients that received 147 abdominal injuries from an isolated abdominal trauma (n = 70 patients) or during multiple trauma (n = 40 patients). Patients were primarily treated at the University Hospital of Umeå from January 2000 to December 2009. The median New Injury Severity Score was 9 (range: 1-57) for 147 abdominal injuries. Most patients (94%) received computed tomography (CT), but only 38% of patients with multiple trauma were diagnosed with CT management succeeded in 82 patients. Surgery was performed for 28 patients, either immediately (n = 17) as result of operative management or later (n = 11), due to non-operative management failure; the latter mainly occurred with hollow viscus injuries. Patients with multiple abdominal injuries, whether associated with multiple trauma or an isolated abdominal trauma, had significantly more non-operative failures than patients with a single abdominal injury. One death occurred within 30 days. Non-operative management of patients with abdominal injuries, except for hollow viscus injuries, was highly successful in our low trauma volume hospital, even though surgeons receive low exposure to these patients. However, a growing proportion of surgeons lack experience in decision-making and performing trauma laparotomies. Quality assurance

  13. [Hospitals failing minimum volumes in 2004: reasons and consequences].

    Science.gov (United States)

    Geraedts, M; Kühnen, C; Cruppé, W de; Blum, K; Ohmann, C

    2008-02-01

    In 2004 Germany introduced annual minimum volumes nationwide on five surgical procedures: kidney, liver, stem cell transplantation, complex oesophageal, and pancreatic interventions. Hospitals that fail to reach the minimum volumes are no longer allowed to perform the respective procedures unless they raise one of eight legally accepted exceptions. The goal of our study was to investigate how many hospitals fell short of the minimum volumes in 2004, whether and how this was justified, and whether hospitals that failed the requirements experienced any consequences. We analysed data on meeting the minimum volume requirements in 2004 that all German hospitals were obliged to publish as part of their biannual structured quality reports. We performed telephone interviews: a) with all hospitals not achieving the minimum volumes for complex oesophageal, and pancreatic interventions, and b) with the national umbrella organisations of all German sickness funds. In 2004, one quarter of all German acute care hospitals (N=485) performed 23,128 procedures where minimum volumes applied. 197 hospitals (41%) did not meet at least one of the minimum volumes. These hospitals performed N=715 procedures (3.1%) where the minimum volumes were not met. In 43% of these cases the hospitals raised legally accepted exceptions. In 33% of the cases the hospitals argued using reasons that were not legally acknowledged. 69% of those hospitals that failed to achieve the minimum volumes for complex oesophageal and pancreatic interventions did not experience any consequences from the sickness funds. However, one third of those hospitals reported that the sickness funds addressed the issue and partially announced consequences for the future. The sickness funds' umbrella organisations stated that there were only sparse activities related to the minimum volumes and that neither uniform registrations nor uniform proceedings in case of infringements of the standards had been agreed upon. In spite of the

  14. Striatal volume predicts level of video game skill acquisition.

    Science.gov (United States)

    Erickson, Kirk I; Boot, Walter R; Basak, Chandramallika; Neider, Mark B; Prakash, Ruchika S; Voss, Michelle W; Graybiel, Ann M; Simons, Daniel J; Fabiani, Monica; Gratton, Gabriele; Kramer, Arthur F

    2010-11-01

    Video game skills transfer to other tasks, but individual differences in performance and in learning and transfer rates make it difficult to identify the source of transfer benefits. We asked whether variability in initial acquisition and of improvement in performance on a demanding video game, the Space Fortress game, could be predicted by variations in the pretraining volume of either of 2 key brain regions implicated in learning and memory: the striatum, implicated in procedural learning and cognitive flexibility, and the hippocampus, implicated in declarative memory. We found that hippocampal volumes did not predict learning improvement but that striatal volumes did. Moreover, for the striatum, the volumes of the dorsal striatum predicted improvement in performance but the volumes of the ventral striatum did not. Both ventral and dorsal striatal volumes predicted early acquisition rates. Furthermore, this early-stage correlation between striatal volumes and learning held regardless of the cognitive flexibility demands of the game versions, whereas the predictive power of the dorsal striatal volumes held selectively for performance improvements in a game version emphasizing cognitive flexibility. These findings suggest a neuroanatomical basis for the superiority of training strategies that promote cognitive flexibility and transfer to untrained tasks.

  15. When high-volume PCI operators in high-volume hospitals move to lower volume hospitals-Do they still maintain high volume and quality of outcomes?

    Science.gov (United States)

    Lu, Tsung-Hsueh; Li, Sheng-Tun; Liang, Fu-Wen; Lee, Jo-Chi; Yin, Wei-Hsian

    2017-10-31

    The aim of this quasi-experimental study was to examine whether high-volume percutaneous coronary intervention (PCI) operators still maintain high volume and quality of outcomes when they moved to lower volume hospitals. Systematic reviews have indicated that high-volume PCI operators and hospitals have higher quality outcomes. However, little is known on whether high PCI volume and high quality outcomes are mainly due to operator characteristics (i.e., skill and experience) and is portable across organizations or whether it is due to hospital characteristics (i.e., equipment, team, and management system) and is less portable. We used Taiwan National Health Insurance claims data 2000-2012 to identify 98 high-volume PCI operators, 10 of whom moved from one hospital to another during the study period. We compared the PCI volume, risk-adjusted mortality ratio, and major adverse cardiovascular event (MACE) ratio before and after moving. Of the 10 high-volume operators who moved, 6 moved from high- to moderate- or low-volume hospitals, with median annual PCI volumes (interquartile range) of 130 (117-165) in prior hospitals and 54 (46-84) in subsequent hospitals (the hospital the operator moved to), and the remaining 4 moved from high to high-volume hospitals, with median annual PCI volumes (interquartile range) of 151 (133-162) in prior hospitals and 193 (178-239) in subsequent hospitals. No significant differences were observed in the risk-adjusted mortality ratios and MACE ratios between high-volume operators and matched controls before and after moving. High-volume operators cannot maintain high volume when they moved from high to moderate or low-volume hospitals; however, the quality of care is maintained. High PCI volume and high-quality outcomes are less portable and more hospital bound. © 2017 Wiley Periodicals, Inc.

  16. USAF Logistics Process Optimization Study for the Aircraft Asset Sustainment Process. Volume 2

    National Research Council Canada - National Science Library

    Adamson, Anthony

    1998-01-01

    .... It is published as three separate volumes. Volume I, USAF Logistics Process Optimization Study for the Aircraft Asset Sustainment Process -- Phase II Report, discusses the result and cost/benefit analysis of testing three initiatives...

  17. USAF Logistics Process Optimization Study for the Aircraft Asset Sustainment Process. Volume 1

    National Research Council Canada - National Science Library

    Adamson, Anthony

    1998-01-01

    .... It is published as three separate volumes. Volume I, USAF Logistics Process Optimization Study for the Aircraft Asset Sustainment Process -- Phase II Report, discusses the result and cost/benefit analysis of testing three initiatives...

  18. Experimental study of dual fuel engine performance using variable LPG composition and engine parameters

    International Nuclear Information System (INIS)

    Elnajjar, Emad; Selim, Mohamed Y.E.; Hamdan, Mohammad O.

    2013-01-01

    Highlights: • The effect of using variable LPG is studied. • Five fuels with propane to butane % volume ratio are: 100-70-55-25-0. • 100% Propane composition shows the highest noise levels with similar performance. • At 45° BTDC injection timing 55% Propane LPG the only fuel experience knocking. • LPG fuels gave similar engine performance, with differences in levels of noise. - Abstract: The present work investigates experimentally the effect of LPG fuel with different composition and engine parameters on the performance of a dual compression engine. Five different blends of LPG fuels are used with Propane to Butane volume ratio of 100:0, 70:30, 55:45, 25:75, and 0:100. A single cylinder, naturally aspirated, four strokes, indirectly injected, water cooled modified Ricardo E6 engine, is used in this study. The study is carried out by measuring the cylinder pressure, engine load, engine speed, crank angle, and the fuel’s flow rate. The engine performance under variable LPG fuel composition, engine load, pilot fuel injection timing, compression ratio, pilot fuel mass and engine speed, are estimated by comparing the following engine parameters: the cylinder maximum pressure, the indicated mean effective pressure, the maximum rate of pressure rise, and the thermal efficiency. The experimental data indicates that the engine parameters are playing a major role on the engine’s performance. Different LPG fuel composition did not show a major effect on the engine efficiency but directly impacted the levels of generated combustion noise

  19. MPCV Exercise Operational Volume Analysis

    Science.gov (United States)

    Godfrey, A.; Humphreys, B.; Funk, J.; Perusek, G.; Lewandowski, B. E.

    2017-01-01

    In order to minimize the loss of bone and muscle mass during spaceflight, the Multi-purpose Crew Vehicle (MPCV) will include an exercise device and enough free space within the cabin for astronauts to use the device effectively. The NASA Digital Astronaut Project (DAP) has been tasked with using computational modeling to aid in determining whether or not the available operational volume is sufficient for in-flight exercise.Motion capture data was acquired using a 12-camera Smart DX system (BTS Bioengineering, Brooklyn, NY), while exercisers performed 9 resistive exercises without volume restrictions in a 1g environment. Data were collected from two male subjects, one being in the 99th percentile of height and the other in the 50th percentile of height, using between 25 and 60 motion capture markers. Motion capture data was also recorded as a third subject, also near the 50th percentile in height, performed aerobic rowing during a parabolic flight. A motion capture system and algorithms developed previously and presented at last years HRP-IWS were utilized to collect and process the data from the parabolic flight [1]. These motions were applied to a scaled version of a biomechanical model within the biomechanical modeling software OpenSim [2], and the volume sweeps of the motions were visually assessed against an imported CAD model of the operational volume. Further numerical analysis was performed using Matlab (Mathworks, Natick, MA) and the OpenSim API. This analysis determined the location of every marker in space over the duration of the exercise motion, and the distance of each marker to the nearest surface of the volume. Containment of the exercise motions within the operational volume was determined on a per-exercise and per-subject basis. The orientation of the exerciser and the angle of the footplate were two important factors upon which containment was dependent. Regions where the exercise motion exceeds the bounds of the operational volume have been

  20. Entorhinal volume, aerobic fitness, and recognition memory in healthy young adults: A voxel-based morphometry study.

    Science.gov (United States)

    Whiteman, Andrew S; Young, Daniel E; Budson, Andrew E; Stern, Chantal E; Schon, Karin

    2016-02-01

    Converging evidence supports the hypothesis effects of aerobic exercise and environmental enrichment are beneficial for cognition, in particular for hippocampus-supported learning and memory. Recent work in humans suggests that exercise training induces changes in hippocampal volume, but it is not known if aerobic exercise and fitness also impact the entorhinal cortex. In animal models, aerobic exercise increases expression of growth factors, including brain derived neurotrophic factor (BDNF). This exercise-enhanced expression of growth hormones may boost synaptic plasticity, and neuronal survival and differentiation, potentially supporting function and structure in brain areas including but not limited to the hippocampus. Here, using voxel based morphometry and a standard graded treadmill test to determine cardio-respiratory fitness (Bruce protocol; ·VO2 max), we examined if entorhinal and hippocampal volumes were associated with cardio-respiratory fitness in healthy young adults (N=33). In addition, we examined if volumes were modulated by recognition memory performance and by serum BDNF, a putative marker of synaptic plasticity. Our results show a positive association between volume in right entorhinal cortex and cardio-respiratory fitness. In addition, average gray matter volume in the entorhinal cortex, bilaterally, was positively associated with memory performance. These data extend prior work on the cerebral effects of aerobic exercise and fitness to the entorhinal cortex in healthy young adults thus providing compelling evidence for a relationship between aerobic fitness and structure of the medial temporal lobe memory system. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Ghana Journal of Development Studies, Volume 7, Number 2

    African Journals Online (AJOL)

    UDS-CAPTURED

    Ghana Journal of Development Studies, Volume 7, Number 2 2010. 53 ... The use of motorcycles for urban passenger transport in Nigeria popularly called okada is a source of ..... Gap in Mexico Washington, DC: The World Bank. Becker, S. G. ...

  2. Inpatient Volume and Quality of Mental Health Care Among Patients With Unipolar Depression

    DEFF Research Database (Denmark)

    Rasmussen, Line Ryberg; Mainz, Jan; Jørgensen, Mette

    2018-01-01

    OBJECTIVE: The relationship between inpatient volume and the quality of mental health care remains unclear. This study examined the association between inpatient volume in psychiatric hospital wards and quality of mental health care among patients with depression admitted to wards in Denmark...... was assessed by receipt of process performance measures reflecting national clinical guidelines for care of depression. RESULTS: Compared with patients admitted to low-volume psychiatric hospital wards, patients admitted to very-high-volume wards were more likely to receive a high overall quality of mental...... wards was associated with a greater chance of receiving guideline-recommended process performance measures for care of depression....

  3. Satellite Power Systems (SPS) concept definition study. Volume 6: SPS technology requirements and verification

    Science.gov (United States)

    Hanley, G.

    1978-01-01

    Volume 6 of the SPS Concept Definition Study is presented and also incorporates results of NASA/MSFC in-house effort. This volume includes a supporting research and technology summary. Other volumes of the final report that provide additional detail are as follows: (1) Executive Summary; (2) SPS System Requirements; (3) SPS Concept Evolution; (4) SPS Point Design Definition; (5) Transportation and Operations Analysis; and Volume 7, SPS Program Plan and Economic Analysis.

  4. The Importance of psychological constructs for training volume and performance improvement. A structural equation model for youth speed skaters

    NARCIS (Netherlands)

    Elferink-Gemser, Marije T.; De Roos, Ilse; Torenbeek, Marjolein; Fokkema, Tryntsje; Jonker, Laura; Visscher, Chris

    2015-01-01

    To investigate the importance of self-regulated learning, motivation, and goal orientation for training volume and performance improvement, 63 talented Dutch speed skaters (n=35 male; n=28 female) aged 11 to 22 completed the Self-Regulation of Learning-Self-Report Scale (SRL-SRS; Toering et al.,

  5. Twenty-fifth water reactor safety information meeting: Proceedings. Volume 2: Human reliability analysis and human performance evaluation; Technical issues related to rulemakings; Risk-informed, performance-based initiatives; High burn-up fuel research

    International Nuclear Information System (INIS)

    Monteleone, S.

    1998-03-01

    This three-volume report contains papers presented at the conference. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Japan, Norway, and Russia. The titles of the papers and the names of the authors have been updated and may differ from those that appeared in the final program of the meeting. This volume contains the following: (1) human reliability analysis and human performance evaluation; (2) technical issues related to rulemakings; (3) risk-informed, performance-based initiatives; and (4) high burn-up fuel research

  6. Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study.

    Science.gov (United States)

    Wallon, G; Bonnet, A; Guérin, C

    2013-06-01

    Tidal volume (V(T)) must be accurately delivered by anaesthesia ventilators in the volume-controlled ventilation mode in order for lung protective ventilation to be effective. However, the impact of fresh gas flow (FGF) and lung mechanics on delivery of V(T) by the newest anaesthesia ventilators has not been reported. We measured delivered V(T) (V(TI)) from four anaesthesia ventilators (Aisys™, Flow-i™, Primus™, and Zeus™) on a pneumatic test lung set with three combinations of lung compliance (C, ml cm H2O(-1)) and resistance (R, cm H2O litre(-1) s(-2)): C60R5, C30R5, C60R20. For each CR, three FGF rates (0.5, 3, 10 litre min(-1)) were investigated at three set V(T)s (300, 500, 800 ml) and two values of PEEP (0 and 10 cm H2O). The volume error = [(V(TI) - V(Tset))/V(Tset)] ×100 was computed in body temperature and pressure-saturated conditions and compared using analysis of variance. For each CR and each set V(T), the absolute value of the volume error significantly declined from Aisys™ to Flow-i™, Zeus™, and Primus™. For C60R5, these values were 12.5% for Aisys™, 5% for Flow-i™ and Zeus™, and 0% for Primus™. With an increase in FGF, absolute values of the volume error increased only for Aisys™ and Zeus™. However, in C30R5, the volume error was minimal at mid-FGF for Aisys™. The results were similar at PEEP 10 cm H2O. Under experimental conditions, the volume error differed significantly between the four new anaesthesia ventilators tested and was influenced by FGF, although this effect may not be clinically relevant.

  7. Performance of Low-Volume Roads with Wearing Course Layer of Silty Sandy Soil Modified with Rice Husk Ash and Lime

    Energy Technology Data Exchange (ETDEWEB)

    Behak Katz, L.; Musso Laespiga, M.

    2016-07-01

    Rice husk ash (RHA) is a by-product of rice milling. Its use as soil stabilizer is a way to replace the final disposal with environmental benefit. However, RHA is not cementitious itself but when mixed with lime forms cements which improve the soil properties. A research of performance of a silty sandy soil modified with RHA and lime as wearing course layer of low-volume roads was conducted through two full-scale test sections with different pavements built in Artigas, northern Uruguay. The alkaline reactivity of RHA is low because the husk burning is not controlled. The soil-RHA-lime mix design was conducted according to the Thompson’s Method. The pavement test sections were monitored through deflection measures by Benkelman beam and observations of surface condition. The deflections decreased over time in both test sections due to the development of cementation of the study materials. After one year, the dust emission was reduced, the wet skid resistance of pavement surfaces improved and there was not rutting. The researched pavements have had a good performance under the existing traffic and environmental conditions, demonstrating that wearing course layer of silty sand modified with RHA and lime is an alternative to improve the condition of low-volume roads and to replace the final disposal of RHA, with environmental, social and economic benefits. (Author)

  8. Cross-correlations in volume space: Differences between buy and sell volumes

    Science.gov (United States)

    Lee, Sun Young; Hwang, Dong Il; Kim, Min Jae; Koh, In Gyu; Kim, Soo Yong

    2011-03-01

    We study the cross-correlations of buy and sell volumes on the Korean stock market in high frequency. We observe that the pulling effects of volumes are as small as that of returns. The properties of the correlations of buy and sell volumes differ. They are explained by the degree of synchronization of stock volumes. Further, the pulling effects on the minimal spanning tree are studied. In minimal spanning trees with directed links, the large pulling effects are clustered at the center, not uniformly distributed. The Epps effect of buy and sell volumes are observed. The reversal of the cross-correlations of buy and sell volumes is also detected.

  9. Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992. Volume 3, Model parameters: Sandia WIPP Project

    Energy Technology Data Exchange (ETDEWEB)

    1992-12-29

    This volume documents model parameters chosen as of July 1992 that were used by the Performance Assessment Department of Sandia National Laboratories in its 1992 preliminary performance assessment of the Waste Isolation Pilot Plant (WIPP). Ranges and distributions for about 300 modeling parameters in the current secondary data base are presented in tables for the geologic and engineered barriers, global materials (e.g., fluid properties), and agents that act upon the WIPP disposal system such as climate variability and human-intrusion boreholes. The 49 parameters sampled in the 1992 Preliminary Performance Assessment are given special emphasis with tables and graphics that provide insight and sources of data for each parameter.

  10. Changes in olfactory bulb volume following lateralized olfactory training.

    Science.gov (United States)

    Negoias, S; Pietsch, K; Hummel, T

    2017-08-01

    Repeated exposure to odors modifies olfactory function. Consequently, "olfactory training" plays a significant role in hyposmia treatment. In addition, numerous studies show that the olfactory bulb (OB) volume changes in disorders associated with olfactory dysfunction. Aim of this study was to investigate whether and how olfactory bulb volume changes in relation to lateralized olfactory training in healthy people. Over a period of 4 months, 97 healthy participants (63 females and 34 males, mean age: 23.74 ± 4.16 years, age range: 19-43 years) performed olfactory training by exposing the same nostril twice a day to 4 odors (lemon, rose, eucalyptus and cloves) while closing the other nostril. Before and after olfactory training, magnetic resonance imaging (MRI) scans were performed to measure OB volume. Furthermore, participants underwent lateralized odor threshold and odor identification testing using the "Sniffin' Sticks" test battery.OB volume increased significantly after olfactory training (11.3 % and 13.1 % respectively) for both trained and untrained nostril. No significant effects of sex, duration and frequency of training or age of the subjects were seen. Interestingly, PEA odor thresholds worsened after training, while olfactory identification remained unchanged.These data show for the first time in humans that olfactory training may involve top-down process, which ultimately lead to a bilateral increase in olfactory bulb volume.

  11. Patient satisfaction: does surgical volume matter?

    Science.gov (United States)

    Tevis, Sarah E; Kennedy, Gregory D

    2015-06-01

    Patient satisfaction is an increasing area of interest due to implications of pay for performance and public reporting of results. Although scores are adjusted for patient factors, little is known about the relationship between hospital structure, postoperative outcomes, and patient satisfaction with the hospital experience. Hospitals participating in the University HealthSystem Consortium database from 2011-2012 were included. Patients were restricted to those discharged by general surgeons to isolate surgical patients. Hospital data were paired with Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) results from the Hospital Compare website. Postoperative outcomes were dichotomized based on the median for all hospitals and stratified based on surgical volume. The primary outcome of interest was high on overall patient satisfaction, whereas other HCAHPS domains were assessed as secondary outcomes. Chi square and binary logistic regression analyses were performed to evaluate whether postoperative outcomes or surgical volume more significantly influenced high patient satisfaction. The study population consisted of 171 hospitals from the University HealthSystem Consortium database. High surgical volume was a more important predictor of overall patient satisfaction regardless of hospital complication (P patient satisfaction on the HCAHPS survey than postoperative outcomes, whereas volume was less predictive in other HCAHPS domains. Patients may require more specific questioning to identify high quality, safe hospitals. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Three-body unitarity in the finite volume

    Energy Technology Data Exchange (ETDEWEB)

    Mai, M. [The George Washington University, Washington, DC (United States); Doering, M. [The George Washington University, Washington, DC (United States); Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2017-12-15

    The physical interpretation of lattice QCD simulations, performed in a small volume, requires an extrapolation to the infinite volume. A method is proposed to perform such an extrapolation for three interacting particles at energies above threshold. For this, a recently formulated relativistic 3 → 3 amplitude based on the isobar formulation is adapted to the finite volume. The guiding principle is two- and three-body unitarity that imposes the imaginary parts of the amplitude in the infinite volume. In turn, these imaginary parts dictate the leading power-law finite-volume effects. It is demonstrated that finite-volume poles arising from the singular interaction, from the external two-body sub-amplitudes, and from the disconnected topology cancel exactly leaving only the genuine three-body eigenvalues. The corresponding quantization condition is derived for the case of three identical scalar-isoscalar particles and its numerical implementation is demonstrated. (orig.)

  13. The study of alteration in left ventricular volume and pressure to volume ratio during exercise in patients with coronary heart disease

    International Nuclear Information System (INIS)

    Liu Zhonglin; Pei Zhuguo; Zang Bin

    1994-01-01

    The alterations induced by exercise in left ventricular end diastolic volume index (EDVI), end systolic volume index (ESVI) and systolic blood pressure to end systolic volume ratio (P/ESV) were studied in 15 normal subjects and 42 patients with coronary heart disease using a non-geometric count-based method and supine bicycle exercise test. Normal subjects had an increase in EDVI and a decrease in ESVI, but coronary heart disease patients had an increase in both EDVI and ESVI. The extent of increase induced by exercise in EDVI was greater in angina patients than that in normal and old myocardial infarction subjects. The P/ESV can be used to evaluate left ventricular systolic pressure-volume relationship. For the P/ESV exercise response, the sensitivity, specificity and accuracy for coronary heart disease were 95%, 93% and 95%, respectively

  14. Finite volume effects on the electric polarizability of neutral hadrons in lattice QCD

    Science.gov (United States)

    Lujan, M.; Alexandru, A.; Freeman, W.; Lee, F. X.

    2016-10-01

    We study the finite volume effects on the electric polarizability for the neutron, neutral pion, and neutral kaon using eight dynamically generated two-flavor nHYP-clover ensembles at two different pion masses: 306(1) and 227(2) MeV. An infinite volume extrapolation is performed for each hadron at both pion masses. For the neutral kaon, finite volume effects are relatively mild. The dependence on the quark mass is also mild, and a reliable chiral extrapolation can be performed along with the infinite volume extrapolation. Our result is αK0 phys=0.356 (74 )(46 )×10-4 fm3 . In contrast, for neutron, the electric polarizability depends strongly on the volume. After removing the finite volume corrections, our neutron polarizability results are in good agreement with chiral perturbation theory. For the connected part of the neutral pion polarizability, the negative trend persists, and it is not due to finite volume effects but likely sea quark charging effects.

  15. Actual performance of mechanical ventilators in ICU: a multicentric quality control study.

    Science.gov (United States)

    Govoni, Leonardo; Dellaca', Raffaele L; Peñuelas, Oscar; Bellani, Giacomo; Artigas, Antonio; Ferrer, Miquel; Navajas, Daniel; Pedotti, Antonio; Farré, Ramon

    2012-01-01

    Even if the performance of a given ventilator has been evaluated in the laboratory under very well controlled conditions, inappropriate maintenance and lack of long-term stability and accuracy of the ventilator sensors may lead to ventilation errors in actual clinical practice. The aim of this study was to evaluate the actual performances of ventilators during clinical routines. A resistance (7.69 cmH(2)O/L/s) - elastance (100 mL/cmH(2)O) test lung equipped with pressure, flow, and oxygen concentration sensors was connected to the Y-piece of all the mechanical ventilators available for patients in four intensive care units (ICUs; n = 66). Ventilators were set to volume-controlled ventilation with tidal volume = 600 mL, respiratory rate = 20 breaths/minute, positive end-expiratory pressure (PEEP) = 8 cmH(2)O, and oxygen fraction = 0.5. The signals from the sensors were recorded to compute the ventilation parameters. The average ± standard deviation and range (min-max) of the ventilatory parameters were the following: inspired tidal volume = 607 ± 36 (530-723) mL, expired tidal volume = 608 ± 36 (530-728) mL, peak pressure = 20.8 ± 2.3 (17.2-25.9) cmH(2)O, respiratory rate = 20.09 ± 0.35 (19.5-21.6) breaths/minute, PEEP = 8.43 ± 0.57 (7.26-10.8) cmH(2)O, oxygen fraction = 0.49 ± 0.014 (0.41-0.53). The more error-prone parameters were the ones related to the measure of flow. In several cases, the actual delivered mechanical ventilation was considerably different from the set one, suggesting the need for improving quality control procedures for these machines.

  16. Volume fractions of DCE-MRI parameter as early predictor of histologic response in soft tissue sarcoma: A feasibility study.

    Science.gov (United States)

    Xia, Wei; Yan, Zhuangzhi; Gao, Xin

    2017-10-01

    To find early predictors of histologic response in soft tissue sarcoma through volume transfer constant (K trans ) analysis based on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). 11 Patients with soft tissue sarcoma of the lower extremity that underwent preoperative chemoradiotherapy followed by limb salvage surgery were included in this retrospective study. For each patient, DCE-MRI data sets were collected before and two weeks after therapy initiation, and histologic tumor cell necrosis rate (TCNR) was reported at surgery. The DCE-MRI volumes were aligned by registration. Then, the aligned volumes were used to obtain the K trans variation map. Accordingly, three sub-volumes (with increased, decreased or unchanged K trans ) were defined and identified, and fractions of the sub-volumes, denoted as F + , F - and F 0 , respectively, were calculated. The predictive ability of volume fractions was determined by using area under a receiver operating characteristic curve (AUC). Linear regression analysis was performed to investigate the relationship between TCNR and volume fractions. In addition, the K trans values of the sub-volumes were compared. The AUC for F - (0.896) and F 0 (0.833) were larger than that for change of tumor longest diameter ΔD (0.625) and the change of mean K trans ΔK trans ¯ (0.792). Moreover, the regression results indicated that TCNR was directly proportional to F 0 (R 2 =0.75, P=0.0003), while it was inversely proportional to F - (R 2 =0.77, P=0.0002). However, TCNR had relatively weak linear relationship with ΔK trans ¯ (R 2 =0.64, P=0.0018). Additionally, TCNR did not have linear relationship with DD (R 2 =0.16, P=0.1246). The volume fraction F - and F 0 have potential as early predictors of soft tissue sarcoma histologic response. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Association between Thigh Muscle Volume and Leg Muscle Power in Older Women.

    Directory of Open Access Journals (Sweden)

    Ulrich Lindemann

    Full Text Available The construct of sarcopenia is still discussed with regard to best appropriate measures of muscle volume and muscle function. The aim of this post-hoc analysis of a cross-sectional experimental study was to investigate and describe the hierarchy of the association between thigh muscle volume and measurements of functional performance in older women. Thigh muscle volume of 68 independently living older women (mean age 77.6 years was measured via magnetic resonance imaging. Isometric strength was assessed for leg extension in a movement laboratory in sitting position with the knee flexed at 90° and for hand grip. Maximum and habitual gait speed was measured on an electronic walk way. Leg muscle power was measured during single leg push and during sit-to-stand performance. Thigh muscle volume was associated with sit-to-stand performance power (r = 0.628, leg push power (r = 0.550, isometric quadriceps strength (r = 0.442, hand grip strength (r = 0.367, fast gait speed (r = 0.291, habitual gait speed (r = 0.256, body mass index (r = 0.411 and age (r = -0.392. Muscle power showed the highest association with thigh muscle volume in healthy older women. Sit-to-stand performance power showed an even higher association with thigh muscle volume compared to single leg push power.

  18. Unbiased estimation of the liver volume by the Cavalieri principle using magnetic resonance images

    International Nuclear Information System (INIS)

    Sahin, Buenyamin; Emirzeoglu, Mehmet; Uzun, Ahmet; Incesu, Luetfi; Bek, Yueksel; Bilgic, Sait; Kaplan, Sueleyman

    2003-01-01

    Objective: It is often useful to know the exact volume of the liver, such as in monitoring the effects of a disease, treatment, dieting regime, training program or surgical application. Some non-invasive methodologies have been previously described which estimate the volume of the liver. However, these preliminary techniques need special software or skilled performers and they are not ideal for daily use in clinical practice. Here, we describe a simple, accurate and practical technique for estimating liver volume without changing the routine magnetic resonance imaging scanning procedure. Materials and methods: In this study, five normal livers, obtained from cadavers, were scanned by 0.5 T MR machine, in horizontal and sagittal planes. The consecutive sections, in 10 mm thickness, were used to estimate the whole volume of the liver by means of the Cavalieri principle. The volume estimations were done by three different performers to evaluate the reproducibility. Results: There are no statistical differences between the performers and real liver volumes (P>0.05). There is also high correlation between the estimates of performers and the real liver volume (r=0.993). Conclusion: We conclude that the combination of MR imaging with the Cavalieri principle is a non-invasive, direct and unbiased technique that can be safely applied to estimate liver volume with a very moderate workload per individual

  19. Temporal, seasonal and weather effects on cycle volume: an ecological study

    Directory of Open Access Journals (Sweden)

    Tin Tin Sandar

    2012-03-01

    Full Text Available Abstract Background Cycling has the potential to provide health, environmental and economic benefits but the level of cycling is very low in New Zealand and many other countries. Adverse weather is often cited as a reason why people do not cycle. This study investigated temporal and seasonal variability in cycle volume and its association with weather in Auckland, New Zealand's largest city. Methods Two datasets were used: automated cycle count data collected on Tamaki Drive in Auckland by using ZELT Inductive Loop Eco-counters and weather data (gust speed, rain, temperature, sunshine duration available online from the National Climate Database. Analyses were undertaken using data collected over one year (1 January to 31 December 2009. Normalised cycle volumes were used in correlation and regression analyses to accommodate differences by hour of the day and day of the week and holiday. Results In 2009, 220,043 bicycles were recorded at the site. There were significant differences in mean hourly cycle volumes by hour of the day, day type and month of the year (p p Conclusions There are temporal and seasonal variations in cycle volume in Auckland and weather significantly influences hour-to-hour and day-to-day variations in cycle volume. Our findings will help inform future cycling promotion activities in Auckland.

  20. Effects of low-volume high-intensity interval training in a community setting: a pilot study.

    Science.gov (United States)

    Reljic, Dejan; Wittmann, Felix; Fischer, Joachim E

    2018-06-01

    High-intensity interval training (HIIT) is emerging as an effective and time-efficient exercise strategy for health promotion. However, most HIIT studies are conducted in laboratory settings and evidence regarding the efficacy of time-efficient "low-volume" HIIT is based mainly on demanding "all-out" protocols. Thus, the aim of this pilot study was to assess the feasibility and efficacy of two low-volume (≤ 30 min time-effort/week), non-all-out HIIT protocols, performed 2 ×/week over 8 weeks in a community-based fitness centre. Thirty-four sedentary men and women were randomised to either 2 × 4-min HIIT (2 × 4-HIIT) or 5 × 1-min HIIT (5 × 1-HIIT) at 85-95% maximal heart rate (HR max ), or an active control group performing moderate-intensity continuous training (MICT, 76 min/week) at 65-75% HR max . The exercise protocols were well tolerated and no adverse events occurred. 2 × 4-HIIT and 5 × 1-HIIT exhibited lower dropout rates (17 and 8 vs. 30%) than MICT. All training modes improved VO 2max (2 × 4-HIIT: + 20%, P HIIT: + 27%, P HIIT protocols required 60% less time commitment. Both HIIT protocols and MICT had positive impact on cholesterol profiles. Only 5 × 1-HIIT significantly improved waist circumference (P HIIT can be feasibly implemented in a community-based setting. Moreover, our data suggest that practical (non-all-out) HIIT that requires as little as 30 min/week, either performed as 2 × 4-HIIT or 5 × 1-HIIT, may induce significant improvements in VO 2max and cardiometabolic risk markers.

  1. Scoping studies to reduce ICPP high-level radioactive waste volumes for final disposal

    International Nuclear Information System (INIS)

    Knecht, D.A.; Berreth, J.R.; Chipman, N.A.; Cole, H.S.; Geczi, L.S.; Kerr, W.B.; Staples, B.A.

    1985-08-01

    This report presents the results of scoping studies carried out to determine the feasibility of the following candidate options to reduce high-level waste volume: (1) low-fluoride, low-volume glass, (2) glass-ceramic and ceramic, (3) Modified Zirflex, (4) inerts removal by neutralization, and (5) modified Fluorinel processes. The results of the scoping studies show that the glass-ceramic/ceramic waste forms and neutralization process with potential HLW volume reductions ranging from 60 to 80% appear feasible, based on laboratory-scale tests. The presently used Fluorinel process modified by reducing HF usage also appears to be feasible and could result in up to a 10% potential volume reduction. If the current process start-up tests verify the practicality, reduced HF usage will be implemented. The low-volume glass and Modified Zirflex processes may also be feasible, based on laboratory tests, but would require significantly more process development and/or modifications and could result in only a 20 to 30% potential volume reduction. Based on these scoping studies, it is recommended that (1) the glass-ceramic/ceramic and neutralization processes be developed further, (2) reduced HF use for the Modified Fluorinel process be implemented as soon as practical and other options reducing chemical usage for criticality control be evaluated, (3) basic development for the glass process be continued as a back-up technology, and (4) laboratory-scale radioactive fuel dissolution testing for the Modified Zirflex process be completed with further process development discontinued unless needed in the future

  2. North American Natural Gas Markets: Selected technical studies. Volume 3

    Energy Technology Data Exchange (ETDEWEB)

    Huntington, H.G.; Schuler, G.E. [eds.

    1989-04-01

    The Energy Modeling Forum (EMF) was established in 1976 at Stanford University to provide a structural framework within which energy experts, analysts, and policymakers could meet to improve their understanding of critical energy problems. The ninth EMF study, North American Natural Gas Markets, was conducted by a working group comprised of leading natural gas analysts and decision-makers from government, private companies, universities, and research and consulting organizations. The EMF 9 working group met five times from October 1986 through June 1988 to discuss key issues and analyze natural gas markets. This third volume includes technical papers that support many of the conclusions discussed in the EMF 9 summary report (Volume 1) and full working group report (Volume 2). These papers discuss the results from the individual models as well as some nonmodeling analysis related to US natural gas imports and industrial natural gas demand. Individual papers have been processed separately for inclusion in the Energy Science and Technology Database.

  3. Individual Global Navigation Satellite Systems in the Space Service Volume

    Science.gov (United States)

    Force, Dale A.

    2015-01-01

    Besides providing position, navigation, and timing (PNT) to terrestrial users, GPS is currently used to provide for precision orbit determination, precise time synchronization, real-time spacecraft navigation, and three-axis control of Earth orbiting satellites. With additional Global Navigation Satellite Systems (GNSS) coming into service (GLONASS, Beidou, and Galileo), it will be possible to provide these services by using other GNSS constellations. The paper, "GPS in the Space Service Volume," presented at the ION GNSS 19th International Technical Meeting in 2006 (Ref. 1), defined the Space Service Volume, and analyzed the performance of GPS out to 70,000 km. This paper will report a similar analysis of the performance of each of the additional GNSS and compare them with GPS alone. The Space Service Volume, defined as the volume between 3,000 km altitude and geosynchronous altitude, as compared with the Terrestrial Service Volume between the surface and 3,000 km. In the Terrestrial Service Volume, GNSS performance will be similar to performance on the Earth's surface. The GPS system has established signal requirements for the Space Service Volume. A separate paper presented at the conference covers the use of multiple GNSS in the Space Service Volume.

  4. Volume measurement study for large scale input accountancy tank

    International Nuclear Information System (INIS)

    Uchikoshi, Seiji; Watanabe, Yuichi; Tsujino, Takeshi

    1999-01-01

    Large Scale Tank Calibration (LASTAC) facility, including an experimental tank which has the same volume and structure as the input accountancy tank of Rokkasho Reprocessing Plant (RRP) was constructed in Nuclear Material Control Center of Japan. Demonstration experiments have been carried out to evaluate a precision of solution volume measurement and to establish the procedure of highly accurate pressure measurement for a large scale tank with dip-tube bubbler probe system to be applied to the input accountancy tank of RRP. Solution volume in a tank is determined from substitution the solution level for the calibration function obtained in advance, which express a relation between the solution level and its volume in the tank. Therefore, precise solution volume measurement needs a precise calibration function that is determined carefully. The LASTAC calibration experiments using pure water showed good result in reproducibility. (J.P.N.)

  5. Volume growth trends in a Douglas-fir levels-of-growing-stock study.

    Science.gov (United States)

    Robert O. Curtis

    2006-01-01

    Mean curves of increment and yield in gross total cubic volume and net merchantable cubic volume were derived from seven installations of the regional cooperative Levels-of-Growing-Stock Study (LOGS) in Douglas-fir. The technique used reduces the seven curves for each treatment for each variable of interest to a single set of readily interpretable mean curves. To a top...

  6. Channeling, volume reflection, and volume capture study of electrons in a bent silicon crystal

    Directory of Open Access Journals (Sweden)

    T. N. Wistisen

    2016-07-01

    Full Text Available We present the experimental data and analysis of experiments conducted at SLAC National Accelerator Laboratory investigating the processes of channeling, volume-reflection and volume-capture along the (111 plane in a strongly bent quasimosaic silicon crystal. These phenomena were investigated at 5 energies: 3.35, 4.2, 6.3, 10.5, and 14.0 GeV with a crystal with bending radius of 0.15 m, corresponding to curvatures of 0.053, 0.066, 0.099, 0.16, and 0.22 times the critical curvature, respectively. Based on the parameters of fitting functions we have extracted important parameters describing the channeling process such as the dechanneling length, the angle of volume reflection, the surface transmission, and the widths of the distribution of channeled particles parallel and orthogonal to the plane.

  7. Control volume based hydrocephalus research; a phantom study

    Science.gov (United States)

    Cohen, Benjamin; Voorhees, Abram; Madsen, Joseph; Wei, Timothy

    2009-11-01

    Hydrocephalus is a complex spectrum of neurophysiological disorders involving perturbation of the intracranial contents; primarily increased intraventricular cerebrospinal fluid (CSF) volume and intracranial pressure are observed. CSF dynamics are highly coupled to the cerebral blood flows and pressures as well as the mechanical properties of the brain. Hydrocephalus, as such, is a very complex biological problem. We propose integral control volume analysis as a method of tracking these important interactions using mass and momentum conservation principles. As a first step in applying this methodology in humans, an in vitro phantom is used as a simplified model of the intracranial space. The phantom's design consists of a rigid container filled with a compressible gel. Within the gel a hollow spherical cavity represents the ventricular system and a cylindrical passage represents the spinal canal. A computer controlled piston pump supplies sinusoidal volume fluctuations into and out of the flow phantom. MRI is used to measure fluid velocity and volume change as functions of time. Independent pressure measurements and momentum flow rate measurements are used to calibrate the MRI data. These data are used as a framework for future work with live patients and normal individuals. Flow and pressure measurements on the flow phantom will be presented through the control volume framework.

  8. Study of liver volume measurement and its clinical application for liver transplantation using multiple-slice spiral CT

    International Nuclear Information System (INIS)

    Peng Zhiyi; Yu Zhefeng; Kuang Pingding; Xiao Shengxiang; Huang Dongsheng; Zheng Shusen; Wu Jian

    2004-01-01

    Objective: To study the accuracy of liver volume measurement using MSCT and its application in liver transplantation. Methods: (1) Experimental study. Ten pig livers were scanned using MSCT with two collimations (3.2 mm and 6.5 mm) and pitch 1.25. Semi-automatic method was used to reconstruct 3D liver models to measure the liver volume. (2) Clinical study. Twenty-three patients received MSCT scan with collimation of 6.5 mm before liver transplantation. Same method was used to calculate the liver volume and the measurement was repeated by the same observer after 1 month. Results: (1) Experimental study. Actual liver volumes were (1134.1 ± 288.0) ml. Liver volumes by MSCT with two collimations were (1125.0 ± 282.5) ml (3.2 mm) and (1101.6 ± 277.6) ml (6.5 mm). The accuracy was (99.5 ± 0.8)% and (97.4 ± 0.8)%, respectively. Both showed same good agreement with actual liver volume: r=0.999, P<0.01 (2) Clinical study. Actual liver volumes were (1455.7±730.0) ml. Liver volume by MSCT was (1462.7 ± 774.1) ml. The accuracy was (99.5±9.6)%, r=0.986, P<0.01. Liver volume measured again was (1449.4 ± 768.9) ml, r=0.991 (P<0.01). Conclusion: MSCT can assess the liver volume correctly, and could be used as a routine step for evaluations before liver transplantation

  9. Performance characteristics of a low-volume PM10 sampler

    Science.gov (United States)

    Four identical PM10 pre-separators, along with four identical low-volume (1m3 hr-1) total suspended particulate (TSP) samplers were tested side-by-side in a controlled laboratory particulate matter (PM) chamber. The four PM10 and four TSP samplers were also tested in an oil pipe-cleaning field to ev...

  10. Advanced transportation system studies technical area 3: Alternate propulsion subsystem concepts, volume 3

    Science.gov (United States)

    Levak, Daniel

    1993-01-01

    The objective of this contract was to provide definition of alternate propulsion systems for both earth-to-orbit (ETO) and in-space vehicles (upper stages and space transfer vehicles). For such propulsion systems, technical data to describe performance, weight, dimensions, etc. was provided along with programmatic information such as cost, schedule, needed facilities, etc. Advanced technology and advanced development needs were determined and provided. This volume separately presents the various program cost estimates that were generated under three tasks: the F-1A Restart Task, the J-2S Restart Task, and the SSME Upper Stage Use Task. The conclusions, technical results, and the program cost estimates are described in more detail in Volume 1 - Executive Summary and in individual Final Task Reports.

  11. Spider phobia is associated with decreased left amygdala volume: a cross-sectional study

    Science.gov (United States)

    2013-01-01

    Background Evidence from animal and human studies imply the amygdala as the most critical structure involved in processing of fear-relevant stimuli. In phobias, the amygdala seems to play a crucial role in the pathogenesis and maintenance of the disorder. However, the neuropathology of specific phobias remains poorly understood. In the present study, we investigated whether patients with spider phobia show altered amygdala volumes as compared to healthy control subjects. Methods Twenty female patients with spider phobia and twenty age-matched healthy female controls underwent magnetic resonance imaging to investigate amygdala volumes. The amygdalae were segmented using an automatic, model-based segmentation tool (FSL FIRST). Differences in amygdala volume were investigated by multivariate analysis of covariance with group as between-subject factor and left and right amygdala as dependent factors. The relation between amygdala volume and clinical features such as symptom severity, disgust sensitivity, trait anxiety and duration of illness was investigated by Spearman correlation analysis. Results Spider phobic patients showed significantly smaller left amygdala volume than healthy controls. No significant difference in right amygdala volume was detected. Furthermore, the diminished amygdala size in patients was related to higher symptom severity, but not to higher disgust sensitivity or trait anxiety and was independent of age. Conclusions In summary, the results reveal a relation between higher symptom severity and smaller left amygdala volume in patients with spider phobia. This relation was independent of other potential confounders such as the disgust sensitivity or trait anxiety. The findings suggest that greater spider phobic fear is associated with smaller left amygdala. However, the smaller left amygdala volume may either stand for a higher vulnerability to develop a phobic disorder or emerge as a consequence of the disorder. PMID:23442196

  12. Large-volume paracentesis with indwelling peritoneal catheter and albumin infusion: a community hospital study

    Directory of Open Access Journals (Sweden)

    Daniel K. Martin

    2016-10-01

    Full Text Available Background: The management of ascites can be problematic. This is especially true in patients with diuretic refractory ascites who develop a tense abdomen. This often results in hypotension and decreased venous return with resulting renal failure. In this paper, we further examine the risks and benefits of utilizing an indwelling peritoneal catheter to remove large-volume ascites over a 72-h period while maintaining intravascular volume and preventing renal failure. Methods: We retrospectively reviewed charts and identified 36 consecutive patients undergoing continuous large-volume paracentesis with an indwelling peritoneal catheter. At the time of drain placement, no patients had signs or laboratory parameters suggestive of spontaneous bacterial peritonitis. The patients underwent ascitic fluid removal through an indwelling peritoneal catheter and were supported with scheduled albumin throughout the duration. The catheter was used to remove up to 3 L every 8 h for a maximum of 72 h. Regular laboratory and ascitic fluid testing was performed. All patients had a clinical follow-up within 3 months after the drain placement. Results: An average of 16.5 L was removed over the 72-h time frame of indwelling peritoneal catheter maintenance. The albumin infusion utilized correlated to 12 mg/L removed. The average creatinine trend improved in a statistically significant manner from 1.37 on the day of admission to 1.21 on the day of drain removal. No patients developed renal failure during the hospital course. There were no documented episodes of neutrocytic ascites or bacterial peritonitis throughout the study review. Conclusion: Large-volume peritoneal drainage with an indwelling peritoneal catheter is safe and effective for patients with tense ascites. Concomitant albumin infusion allows for maintenance of renal function, and no increase in infectious complications was noted.

  13. High Patient Satisfaction of a Hyaluronic Acid Filler Producing Enduring Full-Facial Volume Restoration: An 18-Month Open Multicenter Study.

    Science.gov (United States)

    Talarico, Sergio; Meski, Ana P; Buratini, Laura; Manela-Azulay, Mônica; Simpson, Helen; Sidou, Farzaneh; Kerrouche, Nabil

    2015-12-01

    Volume restoration is an essential part of facial rejuvenation. To assess long-term full-facial volume restoration using HAEL Volume Lidocaine hyaluronic acid filler. An 18-month open study in 60 subjects with at least Grade 2 on the 4-point volume loss scale (VLS) for full face and at least 2 indications affected among chin, temporal areas, jawline, cheeks, cheekbones, and nasolabial folds (NLF). Performance was assessed by VLS, Lemperle rating scale (LRS), investigator Global Aesthetic Improvement Scale (GAIS), and 3-dimensional (3D) imaging. Most subjects (71.6%) had 3 or 4 indications injected, most commonly cheekbones (96.7%) and NLF (93.3%). At 18 months, at least a 1-grade improvement in VLS was observed for full face (68.3% of subjects), chin (77.8%), temporal areas (73.7%), cheeks (66.6%), cheekbones (58.6%), jawline (43.1%), and NLF (71.4%; LRS). For all indications, more than 60% of the volume gained at 3 weeks was sustained at 18 months based on 3D digital imaging. At 18 months, 95.0% of subjects had improved full-face GAIS and all subjects were satisfied with their aesthetic outcome. One subject (1.6%) had treatment-related adverse events. Full-facial volume restoration was well sustained over 18 months with high patient satisfaction and good tolerability.

  14. Combined low-volume polyethylene glycol solution plus stimulant laxatives versus standard-volume polyethylene glycol solution: A prospective, randomized study of colon cleansing before colonoscopy

    Science.gov (United States)

    Hookey, Lawrence C; Depew, William T; Vanner, Stephen J

    2006-01-01

    INTRODUCTION The effectiveness of polyethylene glycol solutions (PEG) for colon cleansing is often limited by the inability of patients to drink adequate portions of the 4 L solution. The aim of the present study was to determine whether a reduced volume of PEG combined with stimulant laxatives would be better tolerated and as or more effective than the standard dose. METHODS Patients undergoing outpatient colonoscopy were randomly assigned to receive either low-volume PEG plus sennosides (120 mg oral sennosides syrup followed by 2 L PEG) or the standard volume preparation (4 L PEG). The subjects rated the tolerability of the preparations and their symptoms. Colonoscopists were blind to the colonic cleansing preparation and graded the cleansing efficacy using a validated tool (the Ottawa scale). RESULTS The low-volume PEG plus sennosides preparation was significantly better tolerated than the standard large volume PEG (Psennosides preparation was better tolerated, it was not as effective as standard large-volume PEG. However, in view of the significant difference in tolerance, further research investigating possible improvements in the reduced-volume regimen seems warranted. PMID:16482236

  15. An analysis of malar fat volume in two age groups: implications for craniofacial surgery.

    Science.gov (United States)

    Corey, Christina L; Popelka, Gerald R; Barrera, Jose E; Most, Sam P

    2012-12-01

    Objective To evaluate how malar fat pad (MFP) volumes vary with age, after controlling for gender and body mass index (BMI). Study Design A prospective case-control study evaluating volume of the MFP in women of two age groups. Methods Soft tissue dimensions were measured in eight subjects using magnetic resonance imaging. A multiplanar localizing sequence, followed in sagittal and coronal orientations using a turbo spin echo sequence, was performed to define the MFP. Volumetric calculations were then performed using a 3D image analysis application (Dextroscope, Volume Interactions, Republic of Singapore) to circumscribe areas, orient dimensions, and calculate volumes of the MFP. Results These data reveal no significant difference in the mean (standard deviation) right MFP (p = 0.50), left MFP (p = 0.41), or total MFP (p = 0.45) volumes when comparing the two age groups. In addition, these data indicate that there was no correlation between age and total MFP volume (Pearson correlation coefficient 0.27). Moreover, there was no correlation between age and the ratio of total volume/BMI (Pearson correlation coefficient -0.18). Conclusions Although the sample size of this study was small, these data indicate that ptosis of midfacial fat is more important than volume loss in midfacial aging. These data would suggest repositioning as the primary modality for craniofacial reconstruction.

  16. Resonant Mode Reduction in Radiofrequency Volume Coils for Ultrahigh Field Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Xiaoliang Zhang

    2011-07-01

    Full Text Available In a multimodal volume coil, only one mode can generate homogeneous Radiofrequency (RF field for Magnetic Resonance Imaging. The existence of other modes may increase the volume coil design difficulties and potentially decreases coil performance. In this study, we introduce common-mode resonator technique to high and ultrahigh field volume coil designs to reduce the resonant mode while maintain the homogeneity of the RF field. To investigate the design method, the common-mode resonator was realized by using a microstrip line which was split along the central to become a pair of parallel transmission lines within which common-mode currents exist. Eight common-mode resonators were placed equidistantly along the circumference of a low loss dielectric cylinder to form a volume coil. Theoretical analysis and comparison between the 16-strut common-mode volume coil and a conventional 16-strut volume coil in terms of RF field homogeneity and efficiency was performed using Finite-Difference Time-Domain (FDTD method at 298.2 MHz. MR imaging experiments were performed by using a prototype of the common-mode volume coil on a whole body 7 Tesla scanner. FDTD simulation results showed the reduced number of resonant modes of the common-mode volume coil over the conventional volume coil, while the RF field homogeneity of the two type volume coils was kept at the same level. MR imaging of a water phantom and a kiwi fruit showing the feasibility of the proposed method for simplifying the volume coil design is also presented.

  17. Impaired Verbal Learning Is Associated with Larger Caudate Volumes in Early Onset Schizophrenia Spectrum Disorders.

    Directory of Open Access Journals (Sweden)

    Monica Juuhl-Langseth

    Full Text Available Both brain structural abnormalities and neurocognitive impairments are core features of schizophrenia. We have previously reported enlargements in subcortical brain structure volumes and impairment of neurocognitive functioning as measured by the MATRICS Cognitive Consensus Battery (MCCB in early onset schizophrenia spectrum disorders (EOS. To our knowledge, no previous study has investigated whether neurocognitive performance and volumetric abnormalities in subcortical brain structures are related in EOS.Twenty-four patients with EOS and 33 healthy controls (HC were included in the study. Relationships between the caudate nucleus, the lateral and fourth ventricles volumes and neurocognitive performance were investigated with multivariate linear regression analyses. Intracranial volume, age, antipsychotic medication and IQ were included as independent predictor-variables.The caudate volume was negatively correlated with verbal learning performance uniquely in the EOS group (r=-.454, p=.034. There were comparable positive correlations between the lateral ventricular volume and the processing speed, attention and reasoning and problem solving domains for both the EOS patients and the healthy controls. Antipsychotic medication was related to ventricular enlargements, but did not affect the brain structure-function relationship.Enlargement of the caudate volume was related to poorer verbal learning performance in patients with EOS. Despite a 32% enlargement of the lateral ventricles in the EOS group, associations to processing speed, attention and reasoning and problem solving were similar for both the EOS and the HC groups.

  18. Blood volume studies in chronic renal failure using radioactive 51Cr

    International Nuclear Information System (INIS)

    Chadda, V.S.; Mehta, S.R.; Mathur, D.

    1975-01-01

    Estimation of blood volume was carried out in 20 healthy subjects and in 25 patients suffering from chronic renal failure using radioactive 51 Cr. A detailed history, physical examination and investigations were also undertaken. On statistical evaluation, the red cell volume was diminished significantly in males and females but rise in blood volume was insignificant. Plasma volume was raised significantly in females but was insignificant in males. The reduction in red cell volume is due to reduced red cell mass because of chronic renal disease. Plasma volume may be elevated in order to compensate for decreased red cell volume. The variability in these two parameters results in variable blood volume. (author)

  19. Change of the human taste bud volume over time.

    Science.gov (United States)

    Srur, Ehab; Stachs, Oliver; Guthoff, Rudolf; Witt, Martin; Pau, Hans Wilhelm; Just, Tino

    2010-08-01

    The specific aim of this study is to measure the taste volume in healthy human subjects over a 2.5-month period and to demonstrate morphological changes of the peripheral taste organs. Eighteen human taste buds in four fungiform papillae (fPap) were examined over a 10-week period. The fungiform papillae investigated were selected based on the form of the papillae or the arrangement of surface taste pores. Measurements were performed over 10 consecutive weeks, with five scans in a day once a week. The following parameters were measured: height and diameter of the taste bud, diameter of the fungiform papilla and diameter of the taste pore. The findings of this exploratory study indicated that (1) taste bud volumes changed over a 10-week period, (2) the interval between two volume maxima within the 10-week period was 3-5 weeks, and (3) the diameter of the fPap did not correlate with the volume of a single taste bud or with the volume of all taste buds in the fPap within the 10-week period. This exploratory in vivo study revealed changes in taste bud volumes in healthy humans with age-related gustatory sensitivity. These findings need to be considered when studying the effect of denervation of fungiform papillae in vivo using confocal microscopy. Crown Copyright 2009. Published by Elsevier Ireland Ltd. All rights reserved.

  20. Rapid estimation of the vertebral body volume: a combination of the Cavalieri principle and computed tomography images

    International Nuclear Information System (INIS)

    Odaci, Ersan; Sahin, Buenyamin; Sonmez, Osman Fikret; Kaplan, Sueleyman; Bas, Orhan; Bilgic, Sait; Bek, Yueksel; Erguer, Hayati

    2003-01-01

    Objective: The exact volume of the vertebral body is necessary for the evaluation, treatment and surgical application of related vertebral body. Thereby, the volume changes of the vertebral body are monitored, such as infectious diseases of vertebra and traumatic or non-traumatic fractures and deformities of the spine. Several studies have been conducted for the assessment of the vertebral body size based on the evaluation of the different criteria of the spine using different techniques. However, we have not found any detailed study in the literature describing the combination of the Cavalieri principle and vertebral body volume estimation. Materials and methods: In the present study we describe a rapid, simple, accurate and practical technique for estimating the volume of vertebral body. Two specimens were taken from the cadavers including ten lumbar vertebras and were scanned in axial, sagittal and coronal section planes by a computed tomography (CT) machine. The consecutive sections in 5 and 3 mm thicknesses were used to estimate the total volume of the vertebral bodies by means of the Cavalieri principle. Furthermore, to evaluate inter-observer differences the volume estimations were carried out by three performers. Results: There were no significant differences between the performers' estimates and real volumes of the vertebral bodies (P>0.05) and also between the performers' volume estimates (P>0.05). The section thickness and the section plains did not affect the accuracy of the estimates (P>0.05). A high correlation was seen between the estimates of performers and the real volumes of the vertebral bodies (r=0.881). Conclusion: We concluded that the combination of CT scanning with the Cavalieri principle is a direct and accurate technique that can be safely applied to estimate the volume of the vertebral body with the mean of 5 min and 11 s workload per vertebra

  1. Systematic study on the performance of elliptic focusing neutron guides

    International Nuclear Information System (INIS)

    Martin Rodriguez, D.; DiJulio, D.D.; Bentley, P.M.

    2016-01-01

    In neutron scattering experiments there is an increasing trend towards the study of smaller volume samples, which make the use of focusing optics more important. Focusing guide geometries based on conic-sections, such as those with parabolic and elliptic shapes, have been extensively used in both recently built neutron instruments and upgrades of existing hardware. A large fraction of proposed instruments at the European Spallation Source feature the requirement of good performance when measuring on small samples. The optimised design of a focusing system comes after time consuming Monte-Carlo (MC) simulations. Therefore, in order to help reduce the time needed to design such focusing systems, it is necessary to study systematically the performance of focusing guides. In the present work, we perform a theoretical analysis of the focusing properties of neutron beams, and validate them using a combination of Monte-Carlo simulations and Particle Swarm Optimisations (PSOs), where there is a close correspondence between the maximum divergence of the beam and the shape of the guide. The analytical results show that two limits can be considered, which bound a range of conic section shapes that provide optimum performance. Finally, we analyse a more realistic guide example and we give an assessment of the importance of the contribution from multiple reflections in different systems.

  2. Investigation on high efficiency volume Bragg gratings performances for spectrometry in space environment

    Science.gov (United States)

    Loicq, Jérôme; Stockman, Y.; Georges, Marc; Gaspar Venancio, Luis M.

    2017-11-01

    The special properties of Volume Bragg Gratings (VBGs) make them good candidates for spectrometry applications where high spectral resolution, low level of straylight and low polarisation sensitivity are required. Therefore it is of interest to assess the maturity and suitability of VBGs as enabling technology for future ESA missions with demanding requirements for spectrometry. The VBGs suitability for space application is being investigated in the frame of a project led by CSL and funded by the European Space Agency. The goal of this work is twofold: first the theoretical advantages and drawbacks of VBGs with respect to other technologies with identical functionalities are assessed, and second the performances of VBG samples in a representative space environment are experimentally evaluated. The performances of samples of two VBGs technologies, the Photo-Thermo-Refractive (PTR) glass and the DiChromated Gelatine (DCG), are assessed and compared in the Hα, O2-B and NIR bands. The tests are performed under vacuum condition combined with temperature cycling in the range of 200 K to 300K. A dedicated test bench experiment is designed to evaluate the impact of temperature on the spectral efficiency and to determine the optical wavefront error of the diffracted beam. Furthermore the diffraction efficiency degradation under gamma irradiation is assessed. Finally the straylight, the diffraction efficiency under conical incidence and the polarisation sensitivity is evaluated.

  3. Novel genetic loci associated with hippocampal volume.

    Science.gov (United States)

    Hibar, Derrek P; Adams, Hieab H H; Jahanshad, Neda; Chauhan, Ganesh; Stein, Jason L; Hofer, Edith; Renteria, Miguel E; Bis, Joshua C; Arias-Vasquez, Alejandro; Ikram, M Kamran; Desrivières, Sylvane; Vernooij, Meike W; Abramovic, Lucija; Alhusaini, Saud; Amin, Najaf; Andersson, Micael; Arfanakis, Konstantinos; Aribisala, Benjamin S; Armstrong, Nicola J; Athanasiu, Lavinia; Axelsson, Tomas; Beecham, Ashley H; Beiser, Alexa; Bernard, Manon; Blanton, Susan H; Bohlken, Marc M; Boks, Marco P; Bralten, Janita; Brickman, Adam M; Carmichael, Owen; Chakravarty, M Mallar; Chen, Qiang; Ching, Christopher R K; Chouraki, Vincent; Cuellar-Partida, Gabriel; Crivello, Fabrice; Den Braber, Anouk; Doan, Nhat Trung; Ehrlich, Stefan; Giddaluru, Sudheer; Goldman, Aaron L; Gottesman, Rebecca F; Grimm, Oliver; Griswold, Michael E; Guadalupe, Tulio; Gutman, Boris A; Hass, Johanna; Haukvik, Unn K; Hoehn, David; Holmes, Avram J; Hoogman, Martine; Janowitz, Deborah; Jia, Tianye; Jørgensen, Kjetil N; Karbalai, Nazanin; Kasperaviciute, Dalia; Kim, Sungeun; Klein, Marieke; Kraemer, Bernd; Lee, Phil H; Liewald, David C M; Lopez, Lorna M; Luciano, Michelle; Macare, Christine; Marquand, Andre F; Matarin, Mar; Mather, Karen A; Mattheisen, Manuel; McKay, David R; Milaneschi, Yuri; Muñoz Maniega, Susana; Nho, Kwangsik; Nugent, Allison C; Nyquist, Paul; Loohuis, Loes M Olde; Oosterlaan, Jaap; Papmeyer, Martina; Pirpamer, Lukas; Pütz, Benno; Ramasamy, Adaikalavan; Richards, Jennifer S; Risacher, Shannon L; Roiz-Santiañez, Roberto; Rommelse, Nanda; Ropele, Stefan; Rose, Emma J; Royle, Natalie A; Rundek, Tatjana; Sämann, Philipp G; Saremi, Arvin; Satizabal, Claudia L; Schmaal, Lianne; Schork, Andrew J; Shen, Li; Shin, Jean; Shumskaya, Elena; Smith, Albert V; Sprooten, Emma; Strike, Lachlan T; Teumer, Alexander; Tordesillas-Gutierrez, Diana; Toro, Roberto; Trabzuni, Daniah; Trompet, Stella; Vaidya, Dhananjay; Van der Grond, Jeroen; Van der Lee, Sven J; Van der Meer, Dennis; Van Donkelaar, Marjolein M J; Van Eijk, Kristel R; Van Erp, Theo G M; Van Rooij, Daan; Walton, Esther; Westlye, Lars T; Whelan, Christopher D; Windham, Beverly G; Winkler, Anderson M; Wittfeld, Katharina; Woldehawariat, Girma; Wolf, Christiane; Wolfers, Thomas; Yanek, Lisa R; Yang, Jingyun; Zijdenbos, Alex; Zwiers, Marcel P; Agartz, Ingrid; Almasy, Laura; Ames, David; Amouyel, Philippe; Andreassen, Ole A; Arepalli, Sampath; Assareh, Amelia A; Barral, Sandra; Bastin, Mark E; Becker, Diane M; Becker, James T; Bennett, David A; Blangero, John; van Bokhoven, Hans; Boomsma, Dorret I; Brodaty, Henry; Brouwer, Rachel M; Brunner, Han G; Buckner, Randy L; Buitelaar, Jan K; Bulayeva, Kazima B; Cahn, Wiepke; Calhoun, Vince D; Cannon, Dara M; Cavalleri, Gianpiero L; Cheng, Ching-Yu; Cichon, Sven; Cookson, Mark R; Corvin, Aiden; Crespo-Facorro, Benedicto; Curran, Joanne E; Czisch, Michael; Dale, Anders M; Davies, Gareth E; De Craen, Anton J M; De Geus, Eco J C; De Jager, Philip L; De Zubicaray, Greig I; Deary, Ian J; Debette, Stéphanie; DeCarli, Charles; Delanty, Norman; Depondt, Chantal; DeStefano, Anita; Dillman, Allissa; Djurovic, Srdjan; Donohoe, Gary; Drevets, Wayne C; Duggirala, Ravi; Dyer, Thomas D; Enzinger, Christian; Erk, Susanne; Espeseth, Thomas; Fedko, Iryna O; Fernández, Guillén; Ferrucci, Luigi; Fisher, Simon E; Fleischman, Debra A; Ford, Ian; Fornage, Myriam; Foroud, Tatiana M; Fox, Peter T; Francks, Clyde; Fukunaga, Masaki; Gibbs, J Raphael; Glahn, David C; Gollub, Randy L; Göring, Harald H H; Green, Robert C; Gruber, Oliver; Gudnason, Vilmundur; Guelfi, Sebastian; Håberg, Asta K; Hansell, Narelle K; Hardy, John; Hartman, Catharina A; Hashimoto, Ryota; Hegenscheid, Katrin; Heinz, Andreas; Le Hellard, Stephanie; Hernandez, Dena G; Heslenfeld, Dirk J; Ho, Beng-Choon; Hoekstra, Pieter J; Hoffmann, Wolfgang; Hofman, Albert; Holsboer, Florian; Homuth, Georg; Hosten, Norbert; Hottenga, Jouke-Jan; Huentelman, Matthew; Hulshoff Pol, Hilleke E; Ikeda, Masashi; Jack, Clifford R; Jenkinson, Mark; Johnson, Robert; Jönsson, Erik G; Jukema, J Wouter; Kahn, René S; Kanai, Ryota; Kloszewska, Iwona; Knopman, David S; Kochunov, Peter; Kwok, John B; Lawrie, Stephen M; Lemaître, Hervé; Liu, Xinmin; Longo, Dan L; Lopez, Oscar L; Lovestone, Simon; Martinez, Oliver; Martinot, Jean-Luc; Mattay, Venkata S; McDonald, Colm; McIntosh, Andrew M; McMahon, Francis J; McMahon, Katie L; Mecocci, Patrizia; Melle, Ingrid; Meyer-Lindenberg, Andreas; Mohnke, Sebastian; Montgomery, Grant W; Morris, Derek W; Mosley, Thomas H; Mühleisen, Thomas W; Müller-Myhsok, Bertram; Nalls, Michael A; Nauck, Matthias; Nichols, Thomas E; Niessen, Wiro J; Nöthen, Markus M; Nyberg, Lars; Ohi, Kazutaka; Olvera, Rene L; Ophoff, Roel A; Pandolfo, Massimo; Paus, Tomas; Pausova, Zdenka; Penninx, Brenda W J H; Pike, G Bruce; Potkin, Steven G; Psaty, Bruce M; Reppermund, Simone; Rietschel, Marcella; Roffman, Joshua L; Romanczuk-Seiferth, Nina; Rotter, Jerome I; Ryten, Mina; Sacco, Ralph L; Sachdev, Perminder S; Saykin, Andrew J; Schmidt, Reinhold; Schmidt, Helena; Schofield, Peter R; Sigursson, Sigurdur; Simmons, Andrew; Singleton, Andrew; Sisodiya, Sanjay M; Smith, Colin; Smoller, Jordan W; Soininen, Hilkka; Steen, Vidar M; Stott, David J; Sussmann, Jessika E; Thalamuthu, Anbupalam; Toga, Arthur W; Traynor, Bryan J; Troncoso, Juan; Tsolaki, Magda; Tzourio, Christophe; Uitterlinden, Andre G; Hernández, Maria C Valdés; Van der Brug, Marcel; van der Lugt, Aad; van der Wee, Nic J A; Van Haren, Neeltje E M; van 't Ent, Dennis; Van Tol, Marie-Jose; Vardarajan, Badri N; Vellas, Bruno; Veltman, Dick J; Völzke, Henry; Walter, Henrik; Wardlaw, Joanna M; Wassink, Thomas H; Weale, Michael E; Weinberger, Daniel R; Weiner, Michael W; Wen, Wei; Westman, Eric; White, Tonya; Wong, Tien Y; Wright, Clinton B; Zielke, Ronald H; Zonderman, Alan B; Martin, Nicholas G; Van Duijn, Cornelia M; Wright, Margaret J; Longstreth, W T; Schumann, Gunter; Grabe, Hans J; Franke, Barbara; Launer, Lenore J; Medland, Sarah E; Seshadri, Sudha; Thompson, Paul M; Ikram, M Arfan

    2017-01-18

    The hippocampal formation is a brain structure integrally involved in episodic memory, spatial navigation, cognition and stress responsiveness. Structural abnormalities in hippocampal volume and shape are found in several common neuropsychiatric disorders. To identify the genetic underpinnings of hippocampal structure here we perform a genome-wide association study (GWAS) of 33,536 individuals and discover six independent loci significantly associated with hippocampal volume, four of them novel. Of the novel loci, three lie within genes (ASTN2, DPP4 and MAST4) and one is found 200 kb upstream of SHH. A hippocampal subfield analysis shows that a locus within the MSRB3 gene shows evidence of a localized effect along the dentate gyrus, subiculum, CA1 and fissure. Further, we show that genetic variants associated with decreased hippocampal volume are also associated with increased risk for Alzheimer's disease (r g =-0.155). Our findings suggest novel biological pathways through which human genetic variation influences hippocampal volume and risk for neuropsychiatric illness.

  4. Ultrasound automated volume calculation in reproduction and in pregnancy.

    Science.gov (United States)

    Ata, Baris; Tulandi, Togas

    2011-06-01

    To review studies assessing the application of ultrasound automated volume calculation in reproductive medicine. We performed a literature search using the keywords "SonoAVC, sonography-based automated volume calculation, automated ultrasound, 3D ultrasound, antral follicle, follicle volume, follicle monitoring, follicle tracking, in vitro fertilization, controlled ovarian hyperstimulation, embryo volume, embryonic volume, gestational sac, and fetal volume" and conducted the search in PubMed, Medline, EMBASE, and the Cochrane Database of Systematic Reviews. Reference lists of identified reports were manually searched for other relevant publications. Automated volume measurements are in very good agreement with actual volumes of the assessed structures or with other validated measurement methods. The technique seems to provide reliable and highly reproducible results under a variety of conditions. Automated measurements take less time than manual measurements. Ultrasound automated volume calculation is a promising new technology which is already used in daily practice especially for assisted reproduction. Improvements to the technology will undoubtedly render it more effective and increase its use. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  5. Cerebellar Volume in Children With Attention-Deficit Hyperactivity Disorder (ADHD).

    Science.gov (United States)

    Wyciszkiewicz, Aleksandra; Pawlak, Mikolaj A; Krawiec, Krzysztof

    2017-02-01

    Attention Deficit Hyperactivity Disorder (ADHD) is associated with altered cerebellar volume and cerebellum is associated with cognitive performance. However there are mixed results regarding the cerebellar volume in young patients with ADHD. To clarify the size and direction of this effect, we conducted the analysis on the large public database of brain images. The aim of this study was to confirm that cerebellar volume in ADHD is smaller than in control subjects in currently the largest publicly available cohort of ADHD subjects.We applied cross-sectional case control study design by comparing 286 ADHD patients (61 female) with age and gender matched control subjects. Volumetric measurements of cerebellum were obtained using automated segmentation with FreeSurfer 5.1. Statistical analysis was performed in R-CRAN statistical environment. Patients with ADHD had significantly smaller total cerebellar volumes (134.5±17.11cm 3 vs.138.90±15.32 cm 3 ). The effect was present in both females and males (males 136.9±14.37 cm 3 vs. 141.20±14.75 cm 3 ; females 125.7±12.34 cm 3 vs. 131.20±15.03 cm 3 ). Age was positively and significantly associated with the cerebellar volumes. These results indicate either delayed or disrupted cerebellar development possibly contributing to ADHD pathophysiology.

  6. Twenty-fifth water reactor safety information meeting: Proceedings. Volume 2: Human reliability analysis and human performance evaluation; Technical issues related to rulemakings; Risk-informed, performance-based initiatives; High burn-up fuel research

    Energy Technology Data Exchange (ETDEWEB)

    Monteleone, S. [comp.] [Brookhaven National Lab., Upton, NY (United States)

    1998-03-01

    This three-volume report contains papers presented at the conference. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Japan, Norway, and Russia. The titles of the papers and the names of the authors have been updated and may differ from those that appeared in the final program of the meeting. This volume contains the following: (1) human reliability analysis and human performance evaluation; (2) technical issues related to rulemakings; (3) risk-informed, performance-based initiatives; and (4) high burn-up fuel research. Selected papers have been indexed separately for inclusion in the Energy Science and Technology Database.

  7. High-volume image quality assessment systems: tuning performance with an interactive data visualization tool

    Science.gov (United States)

    Bresnahan, Patricia A.; Pukinskis, Madeleine; Wiggins, Michael

    1999-03-01

    Image quality assessment systems differ greatly with respect to the number and types of mags they need to evaluate, and their overall architectures. Managers of these systems, however, all need to be able to tune and evaluate system performance, requirements often overlooked or under-designed during project planning. Performance tuning tools allow users to define acceptable quality standards for image features and attributes by adjusting parameter settings. Performance analysis tools allow users to evaluate and/or predict how well a system performs in a given parameter state. While image assessment algorithms are becoming quite sophisticated, duplicating or surpassing the human decision making process in their speed and reliability, they often require a greater investment in 'training' or fine tuning of parameters in order to achieve optimum performance. This process may involve the analysis of hundreds or thousands of images, generating a large database of files and statistics that can be difficult to sort through and interpret. Compounding the difficulty is the fact that personnel charged with tuning and maintaining the production system may not have the statistical or analytical background required for the task. Meanwhile, hardware innovations have greatly increased the volume of images that can be handled in a given time frame, magnifying the consequences of running a production site with an inadequately tuned system. In this paper, some general requirements for a performance evaluation and tuning data visualization system are discussed. A custom engineered solution to the tuning and evaluation problem is then presented, developed within the context of a high volume image quality assessment, data entry, OCR, and image archival system. A key factor influencing the design of the system was the context-dependent definition of image quality, as perceived by a human interpreter. This led to the development of a five-level, hierarchical approach to image quality

  8. A simple method to retrospectively estimate patient dose-area product for chest tomosynthesis examinations performed using VolumeRAD.

    Science.gov (United States)

    Båth, Magnus; Söderman, Christina; Svalkvist, Angelica

    2014-10-01

    The purpose of the present work was to develop and validate a method of retrospectively estimating the dose-area product (DAP) of a chest tomosynthesis examination performed using the VolumeRAD system (GE Healthcare, Chalfont St. Giles, UK) from digital imaging and communications in medicine (DICOM) data available in the scout image. DICOM data were retrieved for 20 patients undergoing chest tomosynthesis using VolumeRAD. Using information about how the exposure parameters for the tomosynthesis examination are determined by the scout image, a correction factor for the adjustment in field size with projection angle was determined. The correction factor was used to estimate the DAP for 20 additional chest tomosynthesis examinations from DICOM data available in the scout images, which was compared with the actual DAP registered for the projection radiographs acquired during the tomosynthesis examination. A field size correction factor of 0.935 was determined. Applying the developed method using this factor, the average difference between the estimated DAP and the actual DAP was 0.2%, with a standard deviation of 0.8%. However, the difference was not normally distributed and the maximum error was only 1.0%. The validity and reliability of the presented method were thus very high. A method to estimate the DAP of a chest tomosynthesis examination performed using the VolumeRAD system from DICOM data in the scout image was developed and validated. As the scout image normally is the only image connected to the tomosynthesis examination stored in the picture archiving and communication system (PACS) containing dose data, the method may be of value for retrospectively estimating patient dose in clinical use of chest tomosynthesis.

  9. A simple method to retrospectively estimate patient dose-area product for chest tomosynthesis examinations performed using VolumeRAD

    Energy Technology Data Exchange (ETDEWEB)

    Båth, Magnus, E-mail: magnus.bath@vgregion.se; Svalkvist, Angelica [Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, Gothenburg SE-413 45, Sweden and Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg SE-413 45 (Sweden); Söderman, Christina [Department of Radiation Physics, Institute of Clinical Sciences, The Sahlgrenska Academy at University of Gothenburg, Gothenburg SE-413 45 (Sweden)

    2014-10-15

    Purpose: The purpose of the present work was to develop and validate a method of retrospectively estimating the dose-area product (DAP) of a chest tomosynthesis examination performed using the VolumeRAD system (GE Healthcare, Chalfont St. Giles, UK) from digital imaging and communications in medicine (DICOM) data available in the scout image. Methods: DICOM data were retrieved for 20 patients undergoing chest tomosynthesis using VolumeRAD. Using information about how the exposure parameters for the tomosynthesis examination are determined by the scout image, a correction factor for the adjustment in field size with projection angle was determined. The correction factor was used to estimate the DAP for 20 additional chest tomosynthesis examinations from DICOM data available in the scout images, which was compared with the actual DAP registered for the projection radiographs acquired during the tomosynthesis examination. Results: A field size correction factor of 0.935 was determined. Applying the developed method using this factor, the average difference between the estimated DAP and the actual DAP was 0.2%, with a standard deviation of 0.8%. However, the difference was not normally distributed and the maximum error was only 1.0%. The validity and reliability of the presented method were thus very high. Conclusions: A method to estimate the DAP of a chest tomosynthesis examination performed using the VolumeRAD system from DICOM data in the scout image was developed and validated. As the scout image normally is the only image connected to the tomosynthesis examination stored in the picture archiving and communication system (PACS) containing dose data, the method may be of value for retrospectively estimating patient dose in clinical use of chest tomosynthesis.

  10. A simple method to retrospectively estimate patient dose-area product for chest tomosynthesis examinations performed using VolumeRAD

    International Nuclear Information System (INIS)

    Båth, Magnus; Svalkvist, Angelica; Söderman, Christina

    2014-01-01

    Purpose: The purpose of the present work was to develop and validate a method of retrospectively estimating the dose-area product (DAP) of a chest tomosynthesis examination performed using the VolumeRAD system (GE Healthcare, Chalfont St. Giles, UK) from digital imaging and communications in medicine (DICOM) data available in the scout image. Methods: DICOM data were retrieved for 20 patients undergoing chest tomosynthesis using VolumeRAD. Using information about how the exposure parameters for the tomosynthesis examination are determined by the scout image, a correction factor for the adjustment in field size with projection angle was determined. The correction factor was used to estimate the DAP for 20 additional chest tomosynthesis examinations from DICOM data available in the scout images, which was compared with the actual DAP registered for the projection radiographs acquired during the tomosynthesis examination. Results: A field size correction factor of 0.935 was determined. Applying the developed method using this factor, the average difference between the estimated DAP and the actual DAP was 0.2%, with a standard deviation of 0.8%. However, the difference was not normally distributed and the maximum error was only 1.0%. The validity and reliability of the presented method were thus very high. Conclusions: A method to estimate the DAP of a chest tomosynthesis examination performed using the VolumeRAD system from DICOM data in the scout image was developed and validated. As the scout image normally is the only image connected to the tomosynthesis examination stored in the picture archiving and communication system (PACS) containing dose data, the method may be of value for retrospectively estimating patient dose in clinical use of chest tomosynthesis

  11. Twenty-fifth water reactor safety information meeting: Proceedings. Volume 3: Thermal hydraulic research and codes; Digital instrumentation and control; Structural performance

    International Nuclear Information System (INIS)

    Monteleone, S.

    1998-04-01

    This three-volume report contains papers presented at the conference. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Japan, Norway, and Russia. The titles of the papers and the names of the authors have been updated and may differ from those that appeared in the final program of the meeting. This volume contains the following: (1) thermal hydraulic research and codes; (2) digital instrumentation and control; (3) structural performance

  12. Correlation of ultrasound estimated placental volume and umbilical cord blood volume in term pregnancy.

    Science.gov (United States)

    Pannopnut, Papinwit; Kitporntheranunt, Maethaphan; Paritakul, Panwara; Kongsomboon, Kittipong

    2015-01-01

    To investigate the correlation between ultrasound measured placental volume and collected umbilical cord blood (UCB) volume in term pregnancy. An observational cross-sectional study of term singleton pregnant women in the labor ward at Maha Chakri Sirindhorn Medical Center was conducted. Placental thickness, height, and width were measured using two-dimensional (2D) ultrasound and calculated for placental volume using the volumetric mathematic model. After the delivery of the baby, UCB was collected and measured for its volume immediately. Then, birth weight, placental weight, and the actual placental volume were analyzed. The Pearson's correlation was used to determine the correlation between each two variables. A total of 35 pregnant women were eligible for the study. The mean and standard deviation of estimated placental volume and actual placental volume were 534±180 mL and 575±118 mL, respectively. The median UCB volume was 140 mL (range 98-220 mL). The UCB volume did not have a statistically significant correlation with the estimated placental volume (correlation coefficient 0.15; p=0.37). However, the UCB volume was significantly correlated with the actual placental volume (correlation coefficient 0.62; pcorrelation coefficient 0.38; p=0.02). The estimated placental volume by 2D ultrasound was not significantly correlated with the UCB volume. Further studies to establish the correlation between the UCB volume and the estimated placental volume using other types of placental imaging may be needed.

  13. Troglitazone treatment increases bone marrow adipose tissue volume but does not affect trabecular bone volume in mice

    DEFF Research Database (Denmark)

    Erikstrup, Lise Tornvig; Mosekilde, Leif; Justesen, J

    2001-01-01

    proliferator activated receptor-gamma (PPARgamma). Histomorphometric analysis of proximal tibia was performed in order to quantitate the amount of trabecular bone volume per total volume (BV/TV %), adipose tissue volume per total volume (AV/TV %), and hematopoietic marrow volume per total volume (HV......Aging is associated with decreased trabecular bone mass and increased adipocyte formation in bone marrow. As osteoblasts and adipocytes share common precursor cells present in the bone marrow stroma, it has been proposed that an inverse relationship exists between adipocyte and osteoblast....../TV %) using the point-counting technique. Bone size did not differ between the two groups. In troglitazone-treated mice, AV/TV was significantly higher than in control mice (4.7+/-2.1% vs. 0.2+/-0.3%, respectively, mean +/- SD, P

  14. Retrospective estimation of patient dose-area product in thoracic spine tomosynthesis performed using VolumeRAD

    International Nuclear Information System (INIS)

    Baath, Magnus; Svalkvist, Angelica; Soederman, Christina

    2016-01-01

    The aim of this study was to evaluate the use of a recently developed method of retrospectively estimating the patient dose-area product (DAP) of a chest tomosynthesis examination, performed using VolumeRAD, in thoracic spine tomosynthesis and to determine the necessary field-size correction factor. Digital imaging and communications in medicine (DICOM) data for the projection radiographs acquired during a thoracic spine tomosynthesis examination were retrieved directly from the modality for 17 patients. Using the previously developed method, an estimated DAP for the tomosynthesis examination was determined from DICOM data in the scout image. By comparing the estimated DAP with the actual DAP registered for the projection radiographs, a field-size correction factor was determined. The field-size correction factor for thoracic spine tomosynthesis was determined to 0.92. Applying this factor to the DAP estimated retrospectively, the maximum difference between the estimated DAP and the actual DAP was <3 %. In conclusion, the previously developed method of retrospectively estimating the DAP in chest tomosynthesis can be applied to thoracic spine tomosynthesis. (authors)

  15. In vitro isotopic determination of diffusion volumes by transferrin labelled with indium 111. study of the correlation with SARI 125; Determination isotopique in vitro de volumes de diffusion par la transferrine marquee a l'indium 111. Etude de la correlation avec la SARI 125

    Energy Technology Data Exchange (ETDEWEB)

    Porot, C.L. [CHU Jean-Minjoz, Service de medecine nucleaire, 25 - Besancon (France); Angoue, O.R. [CHU Jean-Minjoz, laboratoire de biophysique et statistiques, 25 - Besancon (France); Berthetc, L.O. [CHU Jean-Minjoz, 25 - Besancon (France); Ungureanu, C.O.; Boulahdour, H.A.

    2010-07-01

    Serum albumin labeled with iodine 125 (S.A.R.I. 125) is the reference tracer used in measuring isotopic plasma volume. It has been causing a suspension of manufacturing leading to a supply disruption and resulting in the search for an alternative to measure plasma volume under consideration for measuring blood volume. Plasma transferrin labeled with indium-111 (Tf-{sup 111}In) is a potentially useful marker. To this end, we assessed the level of activity to be administered to determine a volume of distribution. The study of the correlation between the volume of distribution values obtained with S.A.R.I. 125 and Tf-{sup 111}In was then performed. Tf is an autologous protein which the labelling is easy and stable. Tf-{sup 111}In is a valid alternative to the S.A.R.I. 125 for measuring the plasma volume. The activity required for this examination shall not exceed 100 micro curies. (N.C.)

  16. Volume-change-free GeTeN films for high-performance phase-change memory

    International Nuclear Information System (INIS)

    Yin, You; Hosaka, Sumio; Zhang, Hui; Liu, Yang; Yu, Qi

    2013-01-01

    N-doping into GeTe is investigated with the aim of reducing the volume change upon crystallization, which usually induces a huge internal stress in phase-change memory devices. It is demonstrated that the thickness change upon crystallization of a N-doped GeTe (GeTeN) film is almost zero when N is doped in an appropriate amount. Cracks resulting from the stress caused by volume change disappear and the mean crystal size decreases by more than 50% upon N-doping into GeTe. It is thought that the volume-change-free behaviour is due to the formation of low-density nitride and grain refinement. (paper)

  17. Rectal compliance as a routine measurement: extreme volumes have direct clinical impact and normal volumes exclude rectum as a problem.

    Science.gov (United States)

    Felt-Bersma, R J; Sloots, C E; Poen, A C; Cuesta, M A; Meuwissen, S G

    2000-12-01

    The clinical impact of rectal compliance and sensitivity measurement is not clear. The aim of this study was to measure the rectal compliance in different patient groups compared with controls and to establish the clinical effect of rectal compliance. Anorectal function tests were performed in 974 consecutive patients (284 men). Normal values were obtained from 24 controls. Rectal compliance measurement was performed by filling a latex rectal balloon with water at a rate of 60 ml per minute. Volume and intraballoon pressure were measured. Volume and pressure at three sensitivity thresholds were recorded for analysis: first sensation, urge, and maximal toleration. At maximal toleration, the rectal compliance (volume/pressure) was calculated. Proctoscopy, anal manometry, anal mucosal sensitivity, and anal endosonography were also performed as part of our anorectal function tests. No effect of age or gender was observed in either controls or patients. Patients with fecal incontinence had a higher volume at first sensation and a higher pressure at maximal toleration (P = 0.03), the presence of a sphincter defect or low or normal anal pressures made no difference. Patients with constipation had a larger volume at first sensation and urge (P 500 ml had complaints of constipation. No correlation between rectal and anal mucosal sensitivity was found. Rectal compliance measurement with a latex balloon is easily feasible. In this series of 974 patients, some patient groups showed an abnormal rectal visceral sensitivity and compliance, but there was an overlap with controls. Rectal compliance measurement gave a good clinical impression about the contribution of the rectum to the anorectal problem. Patients with proctitis and pouchitis had the smallest rectal compliance. A maximal toleration volume 500 ml was only seen in constipated patients, and therapy should be given to prevent further damage to the pelvic floor. Values close to or within the normal range rule out the

  18. Some aspects of free volume studies in molecular substances using positron annihilation experiments

    International Nuclear Information System (INIS)

    Shantarovich, V.P.; Gustov, V.W.; Kevdina, I.B.; Suzuki, T.; Djourelov, N.; Shimazu, A.

    2005-01-01

    Positron annihilation lifetime spectroscopy is accepted now as a method for the studies of elementary free volumes (free volume holes) in solids, in polymers in particular. The aim of this paper is to discuss some problems, the difficulties on the way of this application and to illustrate them by several examples obtained by the authors. (author)

  19. Assessment of tidal volume and thoracoabdominal motion using volume and flow-oriented incentive spirometers in healthy subjects

    Directory of Open Access Journals (Sweden)

    V.F. Parreira

    2005-07-01

    Full Text Available The objective of the present study was to evaluate incentive spirometers using volume- (Coach and Voldyne and flow-oriented (Triflo II and Respirex devices. Sixteen healthy subjects, 24 ± 4 years, 62 ± 12 kg, were studied. Respiratory variables were obtained by respiratory inductive plethysmography, with subjects in a semi-reclined position (45º. Tidal volume, respiratory frequency, minute ventilation, inspiratory duty cycle, mean inspiratory flow, and thoracoabdominal motion were measured. Statistical analysis was performed with Kolmogorov-Smirnov test, t-test and ANOVA. Comparison between the Coach and Voldyne devices showed that larger values of tidal volume (1035 ± 268 vs 947 ± 268 ml, P = 0.02 and minute ventilation (9.07 ± 3.61 vs 7.49 ± 2.58 l/min, P = 0.01 were reached with Voldyne, whereas no significant differences in respiratory frequency were observed (7.85 ± 1.24 vs 8.57 ± 1.89 bpm. Comparison between flow-oriented devices showed larger values of inspiratory duty cycle and lower mean inspiratory flow with Triflo II (0.35 ± 0.05 vs 0.32 ± 0.05 ml/s, P = 0.00, and 531 ± 137 vs 606 ± 167 ml/s, P = 0.00, respectively. Abdominal motion was larger (P < 0.05 during the use of volume-oriented devices compared to flow-oriented devices (52 ± 11% for Coach and 50 ± 9% for Voldyne; 43 ± 13% for Triflo II and 44 ± 14% for Respirex. We observed that significantly higher tidal volume associated with low respiratory frequency was reached with Voldyne, and that there was a larger abdominal displacement with volume-oriented devices.

  20. PETPVC: a toolbox for performing partial volume correction techniques in positron emission tomography

    Science.gov (United States)

    Thomas, Benjamin A.; Cuplov, Vesna; Bousse, Alexandre; Mendes, Adriana; Thielemans, Kris; Hutton, Brian F.; Erlandsson, Kjell

    2016-11-01

    Positron emission tomography (PET) images are degraded by a phenomenon known as the partial volume effect (PVE). Approaches have been developed to reduce PVEs, typically through the utilisation of structural information provided by other imaging modalities such as MRI or CT. These methods, known as partial volume correction (PVC) techniques, reduce PVEs by compensating for the effects of the scanner resolution, thereby improving the quantitative accuracy. The PETPVC toolbox described in this paper comprises a suite of methods, both classic and more recent approaches, for the purposes of applying PVC to PET data. Eight core PVC techniques are available. These core methods can be combined to create a total of 22 different PVC techniques. Simulated brain PET data are used to demonstrate the utility of toolbox in idealised conditions, the effects of applying PVC with mismatched point-spread function (PSF) estimates and the potential of novel hybrid PVC methods to improve the quantification of lesions. All anatomy-based PVC techniques achieve complete recovery of the PET signal in cortical grey matter (GM) when performed in idealised conditions. Applying deconvolution-based approaches results in incomplete recovery due to premature termination of the iterative process. PVC techniques are sensitive to PSF mismatch, causing a bias of up to 16.7% in GM recovery when over-estimating the PSF by 3 mm. The recovery of both GM and a simulated lesion was improved by combining two PVC techniques together. The PETPVC toolbox has been written in C++, supports Windows, Mac and Linux operating systems, is open-source and publicly available.

  1. Impact of robotic technique and surgical volume on the cost of radical prostatectomy.

    Science.gov (United States)

    Hyams, Elias S; Mullins, Jeffrey K; Pierorazio, Phillip M; Partin, Alan W; Allaf, Mohamad E; Matlaga, Brian R

    2013-03-01

    Our present understanding of the effect of robotic surgery and surgical volume on the cost of radical prostatectomy (RP) is limited. Given the increasing pressures placed on healthcare resource utilization, such determinations of healthcare value are becoming increasingly important. Therefore, we performed a study to define the effect of robotic technology and surgical volume on the cost of RP. The state of Maryland mandates that all acute-care hospitals report encounter-level and hospital discharge data to the Health Service Cost Review Commission (HSCRC). The HSCRC was queried for men undergoing RP between 2008 and 2011 (the period during which robot-assisted laparoscopic radical prostatectomy [RALRP] was coded separately). High-volume hospitals were defined as >60 cases per year, and high-volume surgeons were defined as >40 cases per year. Multivariate regression analysis was performed to evaluate whether robotic technique and high surgical volume impacted the cost of RP. There were 1499 patients who underwent RALRP and 2565 who underwent radical retropubic prostatectomy (RRP) during the study period. The total cost for RALRP was higher than for RRP ($14,000 vs 10,100; Probotic surgery has come to dominate the healthcare marketplace, strategies to increase the role of high-volume providers may be needed to improve the cost-effectiveness of prostate cancer surgical therapy.

  2. Equal Pay for Equal Work: Medicare Procedure Volume and Reimbursement for Male and Female Surgeons Performing Total Knee and Total Hip Arthroplasty.

    Science.gov (United States)

    Holliday, Emma B; Brady, Christina; Pipkin, William C; Somerson, Jeremy S

    2018-02-21

    The observed sex gap in physician salary has been the topic of much recent debate in the United States, but it has not been well-described among orthopaedic surgeons. The objective of this study was to evaluate for sex differences in Medicare claim volume and reimbursement among orthopaedic surgeons. The Medicare Provider Utilization and Payment Public Use File was used to compare claim volume and reimbursement between female and male orthopaedic surgeons in 2013. Data were extracted for each billing code per orthopaedic surgeon in the year 2013 for total claims, surgical claims, total knee arthroplasty (TKA) claims, and total hip arthroplasty (THA) claims. A total of 20,546 orthopaedic surgeons who treated traditional Medicare patients were included in the initial analysis. Claim volume and reimbursement received were approximately twofold higher for all claims and more than threefold higher for surgical claims for male surgeons when compared with female surgeons (p 10 TKAs and THAs, respectively, in 2013 for Medicare patients and were included in the subset analyses. Although male surgeons performed a higher mean number of TKAs than female surgeons (mean and standard deviation, 37 ± 33 compared with 26 ± 17, respectively, p men and women for TKA or THA ($1,135 ± $228 compared with $1,137 ± $184 for TKA, respectively, p = 0.380; $1,049 ± $226 compared with $1,043 ± $266 for THA, respectively, p = 0.310). Female surgeons had a lower number of total claims and reimbursements compared with male surgeons. However, among surgeons who performed >10 THAs and TKAs, there were no sex differences in the mean reimbursement payment per surgeon. The number of women in orthopaedics is rising, and there is much interest in how their productivity and compensation compare with their male counterparts.

  3. Volume-based characterization of postocclusion surge.

    Science.gov (United States)

    Zacharias, Jaime; Zacharias, Sergio

    2005-10-01

    To propose an alternative method to characterize postocclusion surge using a collapsible artificial anterior chamber to replace the currently used rigid anterior chamber model. Fundación Oftamológica Los Andes, Santiago, Chile. The distal end of a phacoemulsification handpiece was placed inside a compliant artificial anterior chamber. Digital recordings of chamber pressure, chamber volume, inflow, and outflow were performed during occlusion break of the phacoemulsification tip. The occlusion break profile of 2 different consoles was compared. Occlusion break while using a rigid anterior chamber model produced a simultaneous increase of chamber inflow and outflow. In the rigid chamber model, pressure decreased sharply, reaching negative pressure values. Alternatively, with the collapsible chamber model, a delay was observed in the inflow that occurs to compensate the outflow surge. Also, the chamber pressure drop was smaller in magnitude, never undershooting below atmospheric pressure into negative values. Using 500 mm Hg as vacuum limit, the Infiniti System (Alcon) performed better that the Legacy (Alcon), showing an 18% reduction in peak volume variation. The collapsible anterior chamber model provides a more realistic representation of the postocclusion surge events that occur in the real eye during cataract surgery. Peak volume fluctuation (mL), half volume recovery time(s), and volume fluctuation integral value (mL x s) are proposed as realistic indicators to characterize the postocclusion surge performance. These indicators show that the Infiniti System has a better postocclusion surge behavior than the Legacy System.

  4. submitter Performance studies of CMS workflows using Big Data technologies

    CERN Document Server

    Ambroz, Luca; Grandi, Claudio

    At the Large Hadron Collider (LHC), more than 30 petabytes of data are produced from particle collisions every year of data taking. The data processing requires large volumes of simulated events through Monte Carlo techniques. Furthermore, physics analysis implies daily access to derived data formats by hundreds of users. The Worldwide LHC Computing Grid (WLCG) - an international collaboration involving personnel and computing centers worldwide - is successfully coping with these challenges, enabling the LHC physics program. With the continuation of LHC data taking and the approval of ambitious projects such as the High-Luminosity LHC, such challenges will reach the edge of current computing capacity and performance. One of the keys to success in the next decades - also under severe financial resource constraints - is to optimize the efficiency in exploiting the computing resources. This thesis focuses on performance studies of CMS workflows, namely centrallyscheduled production activities and unpredictable d...

  5. Material properties of large-volume cadmium zinc telluride crystals and their relationship to nuclear detector performance

    International Nuclear Information System (INIS)

    James, R.B.; Lund, J.; Yoon, H.

    1997-01-01

    The material showing the greatest promise today for production of large-volume gamma-ray spectrometers operable at room temperature is cadmium zinc telluride (CZT). Unfortunately, because of deficiencies in the quality of the present material, high-resolution CZT spectrometers have thus far been limited to relatively small dimensions, which makes them inefficient at detecting high photon energies and ineffective for weak radiation signals except in near proximity. To exploit CZT fully, it will be necessary to make substantial improvements in the material quality. Improving the material involves advances in the purity, crystallinity, and control of the electrical compensation mechanism. Sandia National Laboratories, California, in close collaboration with US industry and academia, has initiated efforts to develop a detailed understanding of the underlying material problems limiting the performance of large volume gamma-ray spectrometers and to overcome them through appropriate corrections therein. A variety of analytical and numerical techniques are employed to quantify impurities, compositional and stoichiometric variations, crystallinity, strain, bulk and surface defect states, carrier mobilities and lifetimes, electric field distributions, and contact chemistry. Data from these measurements are correlated with spatial maps of the gamma-ray and alpha particle spectroscopic response to determine improvements in the material purification, crystal growth, detector fabrication, and surface passivation procedures. The results of several analytical techniques will be discussed. The intended accomplishment of this work is to develop a low-cost, high-efficiency CZT spectrometer with an active volume of 5 cm 3 and energy resolution of 1--2% (at 662 keV), which would give the US a new field capability for screening radioactive substances

  6. Fluid Volume Expansion and Depletion in Hemodialysis Patients Lack Association with Clinical Parameters

    Directory of Open Access Journals (Sweden)

    Sylvia Kalainy

    2015-12-01

    Full Text Available Background: Achievement of normal volume status is crucial in hemodialysis (HD, since both volume expansion and volume contraction have been associated with adverse outcome and events. Objectives: The objectives of this study are to assess the prevalence of fluid volume expansion and depletion and to identify the best clinical parameter or set of parameters that can predict fluid volume expansion in HD patients. Design: This study is cross-sectional. Setting: This study was conducted in three hemodialysis units. Patients: In this study, there are 194 HD patients. Methods: Volume status was assessed by multifrequency bio-impedance spectroscopy (The Body Composition Monitor, Fresenius prior to the mid-week HD session. Results: Of all patients, 48 % ( n = 94 were volume-expanded and 9 % of patients were volume-depleted ( n = 17. Interdialytic weight gain was not different between hypovolemic, normovolemic, and hypervolemic patients. Fifty percent of the volume-expanded patients were hypertensive. Paradoxical hypertension was very common (31 % of all patients; its incidence was not different between patient groups. Intradialytic hypotension was relatively common and was more frequent among hypovolemic patients. Multivariate regression analysis identified only four predictors for volume expansion (edema, lower BMI, higher SBP, and smoking. None of these parameters displayed both a good sensitivity and specificity. Limitations: The volume assessment was performed once. Conclusions: The study indicates that volume expansion is highly prevalent in HD population and could not be identified using clinical parameters alone. No clinical parameters were identified that could reliably predict volume status. This study shows that bio-impedance can assist to determine volume status. Volume status, in turn, is not related to intradialytic weight gain and is unable to explain the high incidence of paradoxical hypertension.

  7. Age and gender specific normal values of left ventricular mass, volume and function for gradient echo magnetic resonance imaging: a cross sectional study

    Directory of Open Access Journals (Sweden)

    Allansdotter-Johnsson Ase

    2009-01-01

    Full Text Available Abstract Background Knowledge about age-specific normal values for left ventricular mass (LVM, end-diastolic volume (EDV, end-systolic volume (ESV, stroke volume (SV and ejection fraction (EF by cardiac magnetic resonance imaging (CMR is of importance to differentiate between health and disease and to assess the severity of disease. The aims of the study were to determine age and gender specific normal reference values and to explore the normal physiological variation of these parameters from adolescence to late adulthood, in a cross sectional study. Methods Gradient echo CMR was performed at 1.5 T in 96 healthy volunteers (11–81 years, 50 male. Gender-specific analysis of parameters was undertaken in both absolute values and adjusted for body surface area (BSA. Results Age and gender specific normal ranges for LV volumes, mass and function are presented from the second through the eighth decade of life. LVM, ESV and EDV rose during adolescence and declined in adulthood. SV and EF decreased with age. Compared to adult females, adult males had higher BSA-adjusted values of EDV (p = 0.006 and ESV (p Conclusion LV volumes, mass and function vary over a broad age range in healthy individuals. LV volumes and mass both rise in adolescence and decline with age. EF showed a rapid decline in adolescence compared to changes throughout adulthood. These findings demonstrate the need for age and gender specific normal ranges for clinical use.

  8. Advanced transportation system studies technical area 3: Alternate propulsion subsystem concepts, volume 2

    Science.gov (United States)

    Levak, Daniel

    1993-01-01

    The Alternate Propulsion Subsystem Concepts contract had five tasks defined for the first year. The tasks were: F-1A Restart Study, J-2S Restart Study, Propulsion Database Development, Space Shuttle Main Engine (SSME) Upper Stage Use, and CER's for Liquid Propellant Rocket Engines. The detailed study results, with the data to support the conclusions from various analyses, are being reported as a series of five separate Final Task Reports. Consequently, this volume only reports the required programmatic information concerning Computer Aided Design Documentation, and New Technology Reports. A detailed Executive Summary, covering all the tasks, is also available as Volume 1.

  9. Association of volume of patient encounters with residents' in-training examination performance.

    Science.gov (United States)

    McCoy, Christopher P; Stenerson, Matthew B; Halvorsen, Andrew J; Homme, Jason H; McDonald, Furman S

    2013-08-01

    Patient care and medical knowledge are Accreditation Council for Graduate Medical Education (ACGME) core competencies. The correlation between amount of patient contact and knowledge acquisition is not known. To determine if a correlation exists between the number of patient encounters and in-training exam (ITE) scores in internal medicine (IM) and pediatric residents at a large academic medical center. Retrospective cohort study Resident physicians at Mayo Clinic from July 2006 to June 2010 in IM (318 resident-years) and pediatrics (66 resident-years). We tabulated patient encounters through review of clinical notes in an electronic medical record during post graduate year (PGY)-1 and PGY-2. Using linear regression models, we investigated associations between ITE score and number of notes during the previous PGY, adjusted for previous ITE score, gender, medical school origin, and conference attendance. For IM, PGY-2 admission and consult encounters in the hospital and specialty clinics had a positive linear association with ITE-3 % score (β = 0.02; p = 0.004). For IM, PGY-1 conference attendance is positively associated with PGY-2 ITE performance. We did not detect a correlation between PGY-1 patient encounters and subsequent ITE scores for IM or pediatric residents. No association was found between IM PGY-2 ITE score and inpatient, outpatient, or total encounters in the first year of training. Resident continuity clinic and total encounters were not associated with change in PGY-3 ITE score. We identified a positive association between hospital and subspecialty encounters during the second year of IM training and subsequent ITE score, such that each additional 50 encounters were associated with an increase of 1 % correct in PGY-3 ITE score after controlling for previous ITE performance and continuity clinic encounters. We did not find a correlation for volume of encounters and medical knowledge for IM PGY-1 residents or the pediatric cohort.

  10. Dual-energy MDCT: Comparison of pulmonary artery enhancement on dedicated CT pulmonary angiography, routine and low contrast volume studies

    Energy Technology Data Exchange (ETDEWEB)

    Godoy, Myrna C.B., E-mail: migbarco@gmail.com [New York University Langone Medical Center, Department of Radiology, New York, NY (United States); University of Texas M.D. Anderson Cancer Center, Department of Diagnostic Radiology, Houston, TX (United States); Heller, Samantha L.; Naidich, David P.; Assadourian, Bernard [New York University Langone Medical Center, Department of Radiology, New York, NY (United States); Leidecker, Christianne [Siemens Medical Solutions, Malvern, PA (United States); Schmidt, Bernhard [Siemens Healthcare, Forchheim (Germany); Vlahos, Ioannis [New York University Langone Medical Center, Department of Radiology, New York, NY (United States); St. George' s Hospital NHS Trust, London (United Kingdom)

    2011-08-15

    Purpose: The aim of this study was (a) to compare arterial enhancement in simultaneously acquired high- and low-kilovoltage images; and (b) to determine whether low tube-voltage imaging would permit PE evaluation on routine chest CT studies or CTPA studies performed with a low volume of contrast media. Materials and methods: We compared 20 CTPA studies (CTPA group), 20 routine thoracic CT studies (RT group) and 10 CTPA studies performed with reduced volume of contrast media (RC group). HU values were measured in all groups at 80 kVp and 140 kVp images in multiple pulmonary arterial segments bilaterally. The diagnostic quality of the central and peripheral vascular enhancement and the image noise were evaluated at both energies using a five-point scale. Results: For all patients, the mean CT attenuation values were greater at 80 kVp than 140 kVp images (p < 0.001). At 80 kVp, CTPA group attenuation values were greater than RT group (p = 0.03) with a similar trend at 140 kVp (p = 0.08). At both 140 kVp and 80 kVp, CTPA group attenuation values were greater than RC group (p = 0.02 and p = 0.03, respectively). Qualitative analysis showed that at 140 kVp CTPA studies had better global image quality scores than RT (p = 0.003) and RC (p = 0.001) groups. However, at 80 kVp, there was no significant difference of global image quality between CTPA and the other groups (p = 0.4 and p = 0.5, respectively). Although measurable image noise was greater at 80 kVp than 140 kVp (p < 0.001), qualitative analysis revealed lower image noise at 80 kVp images. Conclusion: DECT at 80 kVp increases arterial enhancement in both CTPA and routine studies. For routine studies this results in central and peripheral enhancement quality equivalent to that of CTPA studies. Low tube-voltage imaging allows marked contrast volume reduction for CTPA. In selected cases, satisfactory lower radiation dose CT might be achievable using lower kVp imaging alone.

  11. The effect of post-wash total progressive motile sperm count and semen volume on pregnancy outcomes in intrauterine insemination cycles: a retrospective study.

    Science.gov (United States)

    Ok, Elvan Koyun; Doğan, Omer Erbil; Okyay, Recep Emre; Gülekli, Bülent

    2013-01-01

    The purpose of this study was to determine the impact of post-wash total progressive motile sperm count (TPMSC) and semen volume on pregnancy outcomes in intrauterine insemination (IUI) cycles. The retrospective study included a total of 156 cycles (141 couples) and was performed in our center over a 24-month period. The semen parameters were recorded for each man and each insemination. The semen samples were re-evaluated after the preparation process. Post-wash TPMSC values were divided into four groups; Group 1: 10×10(6). Post-wash inseminated semen volume was divided into three groups; Group 1: 0.3 mL; Group 2: 0.4 mL; Group 3: 0.5 mL. The effect of post-wash total progressive motile sperm and semen volume on pregnancy outcomes was evaluated. The pregnancy rates per cycle and per couple were 27.56% and 30.49%, respectively. There was not a significant relationship between the inseminated semen volume and pregnancy rate (p>0.05). However, a significant linear-by-linear association was documented between the TPMSC and pregnancy rate (p=0.042). Our findings suggest that the post-wash inseminated semen volume should be between 0.3-0.5 mL. An average post-wash total motile sperm count of 10×10(6) may be a useful threshold value for IUI success, but more studies are needed to determine a cut-off value for TPMSC.

  12. Impacts of Outer Continental Shelf (OCS) development on recreation and tourism. Volume 2. Final report and case studies

    Energy Technology Data Exchange (ETDEWEB)

    1987-04-01

    The final report for the project is comprised of five volumes. The volume presents the study conclusions, summarizes the methodology used (more detail is found in Volume 3), discusses four case study applications of the model, and contains profiles of coastal communities in an Appendix.

  13. Positron annihilation and 129Xe NMR studies of free volume in polymers

    International Nuclear Information System (INIS)

    Nagasaka, Bunsow; Eguchi, Taro; Nakayama, Hirokazu; Nakamura, Nobuo; Ito, Yasuo

    2000-01-01

    The existence and the average size of free volume in bisphenol-A polycarbonate (PC), low-density polyethylene (LDPE), poly (2,6-dimethyl-phenylene oxide)(PPO), and polytetrafluoroethylene (PTFE) were studied by positron annihilation and 129 Xe NMR measurements. The 129 Xe NMR chemical shifts for xenon adsorbed in the polymers indicated that the average pore size of the free volume increased in the following order: PC, LDPE, PPO, and PTFE. This order of the pore size of the free volume agrees well with that estimated from the longest lifetime (τ 3 ) of ortho-positronium formed in the polymers. The unique correlation that δ -1 ∝ r is established between the 129 Xe NMR chemical shift (δ) and the pore size (r), which is deduced from the positron annihilation measurements.

  14. 99mTc-albumin can replace 125I-albumin to determine plasma volume repeatedly

    DEFF Research Database (Denmark)

    Bonfils, Peter K; Damgaard, Morten; Stokholm, Knud H

    2012-01-01

    OBJECTIVE: Plasma volume assessment may be of importance in several disorders. The purpose of the present study was to compare the reliability of plasma volume measurements by technetium-labeled human serum albumin ((99m)Tc-HSA) with a simultaneously performed plasma volume determination...... with iodine-labeled human serum albumin ((125)I-HSA). MATERIALS AND METHODS: In 15 healthy volunteers, simultaneous plasma volume measurements with (99m)Tc-HSA and (125)I-HSA were performed after ½ hour in the supine position. Blood samples were obtained 10, 15, 20, and 30 minutes after the injection...... for accurate retropolation from the plasma counts to time zero to correct for leakage of the isotopes from the circulation. RESULTS: The mean difference (bias) between plasma volume measured with (125)I-albumin and (99m)Tc-albumin was 8 ml (0.1 ml/kg) with limits of agreement (bias ±1.96 SD) ranging from -181...

  15. Volume dose of organs at risk in the irradiated volume

    International Nuclear Information System (INIS)

    Hishikawa, Yoshio; Tanaka, Shinichi; Miura, Takashi

    1984-01-01

    Absorbed dose of organs at risk in the 50% irradiated volume needs to be carefully monitored because there is high risk of radiation injury. This paper reports on the histogram of threedimensional volume dose of organs at risk, which is obtained by computer calculation of CT scans. In order to obtain this histogram, CT is first performed in the irradiation field. The dose in each pixel is then examined by the computer as to each slice. After the pixels of all slices in the organ at risk of the irradiated field are classified according to the doses, the number of pixels in the same dose class is counted. The result is expressed in a histogram. The histogram can show the differences of influence to organs at risk given by various radiation treatment techniques. Total volume dose of organs at risk after radiotherapy can also be obtained by integration of each dose of different treatment techniques. (author)

  16. High volume improves outcomes: The argument for centralization of rectal cancer surgery.

    Science.gov (United States)

    Aquina, Christopher T; Probst, Christian P; Becerra, Adan Z; Iannuzzi, James C; Kelly, Kristin N; Hensley, Bradley J; Rickles, Aaron S; Noyes, Katia; Fleming, Fergal J; Monson, John R T

    2016-03-01

    Centralization of care to "centers of excellence" in Europe has led to improved oncologic outcomes; however, little is known regarding the impact of nonmandated regionalization of rectal cancer care in the United States. The Statewide Planning and Research Cooperative System (SPARCS) was queried for elective abdominoperineal and low anterior resections for rectal cancer from 2000 to 2011 in New York with the use of International Classification of Diseases, Ninth Revision codes. Surgeon volume and hospital volume were grouped into quartiles, and high-volume surgeons (≥ 10 resections/year) and hospitals (≥ 25 resections/year) were defined as the top quartile of annual caseload of rectal cancer resection and compared with the bottom 3 quartiles during analyses. Bivariate and multilevel regression analyses were performed to assess factors associated with restorative procedures, 30-day mortality, and temporal trends in these endpoints. Among 7,798 rectal cancer resections, the overall rate of no-restorative proctectomy and 30-day mortality decreased by 7.7% and 1.2%, respectively, from 2000 to 2011. In addition, there was a linear increase in the proportion of cases performed by both high-volume surgeons and high-volume hospitals and a decrease in the number of surgeons and hospitals performing rectal cancer surgery. High-volume surgeons at high-volume hospitals were associated independently with both less nonrestorative proctectomies (odds ratio 0.65, 95% confidence interval 0.48-0.89) and mortality (odds ratio 0.43, 95% confidence interval 0.21-0.87) rates. No patterns of significant improvement within the volume strata of the surgeon and hospitals were observed over time. This study suggests that the current trend toward regionalization of rectal cancer care to high-volume surgeons and high-volume centers has led to improved outcomes. These findings have implications regarding the policy of health care delivery in the United States, supporting referral to high-volume

  17. HIGH-PERFORMANCE COMPUTING FOR THE STUDY OF EARTH AND ENVIRONMENTAL SCIENCE MATERIALS USING SYNCHROTRON X-RAY COMPUTED MICROTOMOGRAPHY

    International Nuclear Information System (INIS)

    FENG, H.; JONES, K.W.; MCGUIGAN, M.; SMITH, G.J.; SPILETIC, J.

    2001-01-01

    Synchrotron x-ray computed microtomography (CMT) is a non-destructive method for examination of rock, soil, and other types of samples studied in the earth and environmental sciences. The high x-ray intensities of the synchrotron source make possible the acquisition of tomographic volumes at a high rate that requires the application of high-performance computing techniques for data reconstruction to produce the three-dimensional volumes, for their visualization, and for data analysis. These problems are exacerbated by the need to share information between collaborators at widely separated locations over both local and tide-area networks. A summary of the CMT technique and examples of applications are given here together with a discussion of the applications of high-performance computing methods to improve the experimental techniques and analysis of the data

  18. HIGH-PERFORMANCE COMPUTING FOR THE STUDY OF EARTH AND ENVIRONMENTAL SCIENCE MATERIALS USING SYNCHROTRON X-RAY COMPUTED MICROTOMOGRAPHY.

    Energy Technology Data Exchange (ETDEWEB)

    FENG,H.; JONES,K.W.; MCGUIGAN,M.; SMITH,G.J.; SPILETIC,J.

    2001-10-12

    Synchrotron x-ray computed microtomography (CMT) is a non-destructive method for examination of rock, soil, and other types of samples studied in the earth and environmental sciences. The high x-ray intensities of the synchrotron source make possible the acquisition of tomographic volumes at a high rate that requires the application of high-performance computing techniques for data reconstruction to produce the three-dimensional volumes, for their visualization, and for data analysis. These problems are exacerbated by the need to share information between collaborators at widely separated locations over both local and tide-area networks. A summary of the CMT technique and examples of applications are given here together with a discussion of the applications of high-performance computing methods to improve the experimental techniques and analysis of the data.

  19. Impact of Different CT Slice Thickness on Clinical Target Volume for 3D Conformal Radiation Therapy

    International Nuclear Information System (INIS)

    Prabhakar, Ramachandran; Ganesh, Tharmar; Rath, Goura K.; Julka, Pramod K.; Sridhar, Pappiah S.; Joshi, Rakesh C.; Thulkar, Sanjay

    2009-01-01

    The purpose of this study was to present the variation of clinical target volume (CTV) with different computed tomography (CT) slice thicknesses and the impact of CT slice thickness on 3-dimensional (3D) conformal radiotherapy treatment planning. Fifty patients with brain tumors were selected and CT scans with 2.5-, 5-, and 10-mm slice thicknesses were performed with non-ionic contrast enhancement. The patients were selected with tumor volume ranging from 2.54 cc to 222 cc. Three-dimensional treatment planning was performed for all three CT datasets. The target coverage and the isocenter shift between the treatment plans for different slice thickness were correlated with the tumor volume. An important observation from our study revealed that for volume 25 cc, the target underdosage was less than 6.7% for 5-mm slice thickness and 8% for 10-mm slice thickness. For 3D conformal radiotherapy treatment planning (3DCRT), a CT slice thickness of 2.5 mm is optimum for tumor volume 25 cc

  20. Nuclear legislation analytical study. Regulatory and institutional framework for nuclear activities in OECD member countries. Volume II

    International Nuclear Information System (INIS)

    1984-01-01

    This study is part of a series of analytical studies of the major aspects of nuclear legislation in OECD Member countries and is published in two volumes. This volume II of the study is a revision and an expansion of a 1969 study concerning the organisation and general regime governing nuclear activities. The national studies were prepared, to the extent possible, following a standard plan for all countries to facilitate information retrieval and comparison. This volume also contains tables of international conventions of relevance to the nuclear field. (NEA) [fr

  1. Acid Pit Stabilization Project (Volume 1 - Cold Testing) and (Volume 2 - Hot Testing)

    International Nuclear Information System (INIS)

    Loomis, G. G.; Zdinak, A. P.; Ewanic, M. A.; Jessmore, J. J.

    1998-01-01

    During the summer and fall of Fiscal Year 1997, a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Treatability Study was performed at the Idaho National Engineering and Environmental Laboratory. The study involved subsurface stabilization of a mixed waste contaminated soil site called the Acid Pit. This study represents the culmination of a successful technology development effort that spanned Fiscal Years 1994-1996. Research and development of the in situ grout stabilization technique was conducted. Hardware and implementation techniques are currently documented in a patent pending with the United States Patent and Trademark Office. The stabilization technique involved using jet grouting of an innovative grouting material to form a monolith out of the contamination zone. The monolith simultaneously provides a barrier to further contaminant migration and closes voids in the soil structure against further subsidence. This is accomplished by chemical incorporation of contaminants into less soluble species and achieving a general reduction in hydraulic conductivity within the monolith. The grout used for this study was TECT-HG, a relatively dense iron oxide-based cementitious grout. The treatability study involved cold testing followed by in situ stabilization of the Acid Pit. Volume 1 of this report discusses cold testing, performed as part of a ''Management Readiness Assessment'' in preparation for going hot. Volume 2 discusses the results of the hot Acid Pit Stabilization phase of this project. Drilling equipment was specifically rigged to reduce the spread of contamination, and all grouting was performed under a concrete block containing void space to absorb any grout returns. Data evaluation included examination of implementability of the grouting process and an evaluation of the contaminant spread during grouting. Following curing of the stabilized pit, cores were obtained and evaluated for toxicity characteristic leach ing

  2. Study on volumetry by MR images using our own making phantoms of known volume

    International Nuclear Information System (INIS)

    Tsuji, Akio; Matsuo, Michimasa; Kuroda, Yasumasa; Nishiki, Shigeo; Iwaya, Kazuo; Tada, Katsunori; Matsushita, Yoko; Okayama, Yukinari

    1990-01-01

    The volumetry of the left atrium has been attempted with various methods including CT, ultrasonography or angiography in patients with the heart diseases. However, there are still some controversies in the results estimated because of complicated shape of the left atrium. MR imaging has also become expecting for its less invasiveness and capability of cine-mode display. To solve the basic problem, we performed experimental studies on the self-made phantoms; one for simulation volumetry and the other for examining the inhomogeneity of the magnetic field. The data analysis system consists of a personal computer (PC 9801VX, NEC) hooked into a 1.0 tesla MR unit (Magnetom M10, Siemens), and a commercially-available software for the three-dimensional reconstruction. The results included; 1) good correlation between the true phantom volume and the measured, 2) excellent reproducibility in the maneuver of tracing the contour of the phantom on CRT screen among five different persons, 3) overestimation of MR volumetry on more oblique slices likely due to partial volume phenomenon, and 4) maximum difference of localization remaining to measure several millimeters within the atrium phantom. These results suggest that the presented method can be clinically applied to the left atrial volumetry in each cardiac phase, if necessary. (author)

  3. Prognostic Factors for Hormone Sensitive Metastatic Prostate Cancer: Impact of Disease Volume

    Science.gov (United States)

    Alhanafy, Alshimaa Mahmoud; Zanaty, Fouad; Ibrahem, Reda; Omar, Suzan

    2018-04-27

    Background and Aim: The optimal management of metastatic hormone-sensitive prostate cancer has been controversial in recent years with introduction of upfront chemohormonal treatment based on results of several Western studies. This changing landscape has renewed interest in the concept “disease volume”, the focus of the present study is the Egyptian patients. Methods: Patients with hormone sensitive metastatic prostate cancer presenting at Menoufia University Hospital, Egypt, during the period from June 2013 to May 2016, were enrolled. All received hormonal treatment. Radiologic images were evaluated and patients were stratified according to their disease volume into high or low, other clinical and pathological data that could affect survival also being collected and analyzed. Results: A total of 128 patients were included, with a median age of 70 years (53.9% ≥70). About 46% had co-morbidities, 62% having high volume disease. During the median follow up period of 28 months about half of the patients progressed and one third received chemotherapy. On univariate analysis, disease volume, performance status (PS), prostate specific antigen level (PSA) and presence of pain at presentation were identified as factors influencing overall survival. Multivariate analysis revealed the independent predictor factors for survival to be PS, PSA and disease volume. The median overall survival with 27 months was high volume versus 49 with low volume disease (hazard ratio 2.1; 95% CI 1.2 - 4.4; P=0.02). Median progression free survival was 19 months in the high volume, as compared with 48 months in the low volume disease patients (hazard ratio, 2.44; 95% CI, 1.42 – 7.4; P=0.009). Conclusions: Disease volume is a reliable predictor of survival which should be incorporated with other important factors as; patient performance status and comorbidities in treatment decision-making. Creative Commons Attribution License

  4. Three-dimensional volume rendering of tibiofibular joint space and quantitative analysis of change in volume due to tibiofibular syndesmosis diastases

    International Nuclear Information System (INIS)

    Taser, F.; Shafiq, Q.; Ebraheim, N.A.

    2006-01-01

    The diagnosis of ankle syndesmosis injuries is made by various imaging techniques. The present study was undertaken to examine whether the three-dimensional reconstruction of axial CT images and calculation of the volume of tibiofibular joint space enhances the sensitivity of diastases diagnoses or not. Six adult cadaveric ankle specimens were used for spiral CT-scan assessment of tibiofibular syndesmosis. After the specimens were dissected, external fixation was performed and diastases of 1, 2, and 3 mm was simulated by a precalibrated device. Helical CT scans were obtained with 1.0-mm slice thickness. The data was transferred to the computer software AcquariusNET. Then the contours of the tibiofibular syndesmosis joint space were outlined on each axial CT slice and the collection of these slices were stacked using the computer software AutoCAD 2005, according to the spatial arrangement and geometrical coordinates between each slice, to produce a three-dimensional reconstruction of the joint space. The area of each slice and the volume of the entire tibiofibular joint space were calculated. The tibiofibular joint space at the 10th-mm slice level was also measured on axial CT scan images at normal, 1, 2 and 3-mm joint space diastases. The three-dimensional volume-rendering of the tibiofibular syndesmosis joint space from the spiral CT data demonstrated the shape of the joint space and has been found to be a sensitive method for calculating joint space volume. We found that, from normal to 1 mm, a 1-mm diastasis increases approximately 43% of the joint space volume, while from 1 to 3 mm, there is about a 20% increase for each 1-mm increase. Volume calculation using this method can be performed in cases of syndesmotic instability after ankle injuries and for preoperative and postoperative evaluation of the integrity of the tibiofibular syndesmosis. (orig.)

  5. Quantitative study on lung volume and lung perfusion using SPECT and CT in thoracal tumors

    International Nuclear Information System (INIS)

    Beyer-Enke, S.A.; Goerich, J.; Strauss, L.G.

    1988-01-01

    22 patients with space occupying lesions in the thoracal region were investigated by computer tomography and by perfusion scintigraphy using SPECT. In order to evaluate the CT images quantitatively, the lung volume was determined using approximation method and compared with the perfusion in the SPECT study. For this, anatomically equivalent transaxial SPECT slices had been coordinated to the CT slices. Between the determined lung volumes and the activity in the ocrresponding layers, a statistically significant correlation was found. It could be shown that the stronger perfusion, frequently observed at the right side of the healthy lung, may be explained by an higher volume of the right pulmonary lobe. Whereas in benign displacing processes the relation activity to volume was similar to the one of the healthy lung, a strongly reduced perfusion together with inconspicuous lung volumes became apparent with malignant tumors. In addition to the great morphological evidence of CT and SPECT studies, additional informations regarding the dignity of displacing processes may be derived from the quantitative evaluation of both methods. (orig.) [de

  6. Fuzzy hidden Markov chains segmentation for volume determination and quantitation in PET

    Energy Technology Data Exchange (ETDEWEB)

    Hatt, M [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609 (France); Lamare, F [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609, (France); Boussion, N [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609 (France); Turzo, A [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609 (France); Collet, C [Ecole Nationale Superieure de Physique de Strasbourg (ENSPS), ULP, Strasbourg, F-67000 (France); Salzenstein, F [Institut d' Electronique du Solide et des Systemes (InESS), ULP, Strasbourg, F-67000 (France); Roux, C [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609 (France); Jarritt, P [Medical Physics Agency, Royal Victoria Hospital, Belfast (United Kingdom); Carson, K [Medical Physics Agency, Royal Victoria Hospital, Belfast (United Kingdom); Rest, C Cheze-Le [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609 (France); Visvikis, D [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Bat 2bis (I3S), 5 avenue Foch, Brest, 29609 (France)

    2007-07-21

    Accurate volume of interest (VOI) estimation in PET is crucial in different oncology applications such as response to therapy evaluation and radiotherapy treatment planning. The objective of our study was to evaluate the performance of the proposed algorithm for automatic lesion volume delineation; namely the fuzzy hidden Markov chains (FHMC), with that of current state of the art in clinical practice threshold based techniques. As the classical hidden Markov chain (HMC) algorithm, FHMC takes into account noise, voxel intensity and spatial correlation, in order to classify a voxel as background or functional VOI. However the novelty of the fuzzy model consists of the inclusion of an estimation of imprecision, which should subsequently lead to a better modelling of the 'fuzzy' nature of the object of interest boundaries in emission tomography data. The performance of the algorithms has been assessed on both simulated and acquired datasets of the IEC phantom, covering a large range of spherical lesion sizes (from 10 to 37 mm), contrast ratios (4:1 and 8:1) and image noise levels. Both lesion activity recovery and VOI determination tasks were assessed in reconstructed images using two different voxel sizes (8 mm{sup 3} and 64 mm{sup 3}). In order to account for both the functional volume location and its size, the concept of % classification errors was introduced in the evaluation of volume segmentation using the simulated datasets. Results reveal that FHMC performs substantially better than the threshold based methodology for functional volume determination or activity concentration recovery considering a contrast ratio of 4:1 and lesion sizes of <28 mm. Furthermore differences between classification and volume estimation errors evaluated were smaller for the segmented volumes provided by the FHMC algorithm. Finally, the performance of the automatic algorithms was less susceptible to image noise levels in comparison to the threshold based techniques. The

  7. Provider volume and outcomes for abdominal aortic aneurysm repair, carotid endarterectomy, and lower extremity revascularization procedures.

    LENUS (Irish Health Repository)

    Killeen, Shane D

    2012-02-03

    BACKGROUND: Intuitively, vascular procedures performed by high-volume vascular subspecialists working at high-volume institutions should be associated with improved patient outcome. Although a large number of studies assess the relationship between volume and outcome, a single contemporary compilation of such studies is lacking. METHODS: A review of the English language literature was performed incorporating searches of the Medline, EMBASE, and Cochrane collaboration databases for abdominal aortic aneurysm repair (elective and emergent), carotid endarterectomy, and arterial lower limb procedures for any volume outcome relationship. Studies were included if they involved a patient cohort from 1980 onwards, were community or population based, and assessed health outcomes (mortality and morbidity) as a dependent variable and volume as an independent variable. RESULTS: We identified 74 relevant studies, and 54 were included. All showed either an inverse relationship of variable magnitude between provider volume and mortality, or no volume-outcome effect. The reduction in the risk-adjusted mortality rate (RAMR) for high-volume providers was 3% to 11% for elective abdominal aortic aneurysm (AAA) repair, 2.5 to 5% for emergent AAA repair, 0.7% to 4.7% carotid endarterectomy, and 0.3% to 0.9% for lower limb arterial bypass procedures. Subspeciality training also conferred a considerable morbidity and mortality benefit for emergent AAA repair, carotid endarterectomy, and lower limb arterial procedures. CONCLUSION: High-volume providers have significantly better outcomes for vascular procedures both in the elective and emergent setting. Subspeciality training also has a considerable impact. These data provide further evidence for the specialization of vascular services, whereby vascular procedures should generally be preformed by high-volume, speciality trained providers.

  8. Changes in Upper Airway Volume Following Orthognathic Surgery.

    Science.gov (United States)

    Marcussen, Lillian; Stokbro, Kasper; Aagaard, Esben; Torkov, Peter; Thygesen, Torben

    2017-01-01

    Reduced volume of the internal skeletal dimensions of the face is 1 of the main causes of obstructive sleep apnea, and attention to patients' airways is necessary when planning orthognathic treatment. This study aims to describe changes in upper airway volume following virtually planned orthognathic surgery.A retrospective pilot study was designed with 30 randomly selected patients (10 men and 20 women, aged 23.1 ± 6.8 years, molar-relations: 15 neutral, 8 distal, and 7 mesial). Cone-beam computed tomography scans were performed before surgery and 1 week following surgery. The authors did total upper airway volume measurements and obtained 1-mm slices at vertical levels in the velo-, oro-, and hypopharynx and at the smallest visible cross-section.Measurements before and after surgery were compared using Student t test.After orthognathic surgery, the minimum cross-sectional area at the vertical level increased from 83 mm ± 33 before surgery to 102 mm ± 36 after surgery (P = 0.019). In patients with neutral and distal occlusions, the minimum cross-sectional slice volume increased in 87% but in only 57% with mesial occlusion.The present findings suggest that orthognathic surgery increases upper airway volume parameters, but a few patients have continued impairment of the airways following orthognathic surgery. Further studies are needed to confirm an individual surgical planning approach that potentially could bring the minimum cross sectional area out of the risk zone.

  9. Industrial experience feedback of a geostatistical estimation of contaminated soil volumes - 59181

    International Nuclear Information System (INIS)

    Faucheux, Claire; Jeannee, Nicolas

    2012-01-01

    Geo-statistics meets a growing interest for the remediation forecast of potentially contaminated sites, by providing adapted methods to perform both chemical and radiological pollution mapping, to estimate contaminated volumes, potentially integrating auxiliary information, and to set up adaptive sampling strategies. As part of demonstration studies carried out for GeoSiPol (Geo-statistics for Polluted Sites), geo-statistics has been applied for the detailed diagnosis of a former oil depot in France. The ability within the geo-statistical framework to generate pessimistic / probable / optimistic scenarios for the contaminated volumes allows a quantification of the risks associated to the remediation process: e.g. the financial risk to excavate clean soils, the sanitary risk to leave contaminated soils in place. After a first mapping, an iterative approach leads to collect additional samples in areas previously identified as highly uncertain. Estimated volumes are then updated and compared to the volumes actually excavated. This benchmarking therefore provides a practical feedback on the performance of the geo-statistical methodology. (authors)

  10. Relations between brain volumes, neuropsychological assessment and parental questionnaire in prematurely born children.

    Science.gov (United States)

    Lind, Annika; Haataja, Leena; Rautava, Liisi; Väliaho, Anniina; Lehtonen, Liisa; Lapinleimu, Helena; Parkkola, Riitta; Korkman, Marit

    2010-05-01

    The objective of this study is to assess the relationship between brain volumes at term equivalent age and neuropsychological functions at 5 years of age in very low birth weight (VLBW) children, and to compare the results from a neuropsychological assessment and a parental questionnaire at 5 years of age. The study group included a regional cohort of 97 VLBW children and a control group of 161 children born at term. At term equivalent age, brain magnetic resonance imaging (MRI) was performed on the VLBW children, and analysed for total and regional brain volumes. At 5 years of age, a psychologist assessed the neuropsychological performance with NEPSY II, and parents completed the Five to fifteen (FTF) questionnaire on development and behaviour. The results of the control group were used to give the age-specific reference values. No significant associations were found between the brain volumes and the NEPSY II domains. As for the FTF, significant associations were found between a smaller total brain tissue volume and poorer executive functions, between a smaller cerebellar volume and both poorer executive functions and motor skills, and, surprisingly, between a larger volume of brainstem and poorer language functions. Even after adjustment for total brain tissue volume, the two associations between the cerebellar volume and the FTF domains remained borderline significant (P = 0.05). The NEPSY II domains Executive Functioning, Language and Motor Skills were significantly associated with the corresponding FTF domains. In conclusion, altered brain volumes at term equivalent age appear to affect development still at 5 years of age. The FTF seems to be a good instrument when used in combination with other neuropsychological assessment.

  11. Effects of buffer ionization in protein transition volumes.

    Science.gov (United States)

    Lee, Soyoung; Heerklotz, Heiko; Chalikian, Tigran V

    2010-05-01

    Protein denaturation events are generally associated with a change in the state of ionization of abnormally titrating groups and, therefore, are coupled with changes in buffer ionization/neutralization equilibria. Consequently, buffer ionization should influence the measured change in volume accompanying protein denaturation. Changes in volume accompanying protein denaturation reflect the differential packing and hydration of polypeptide chains in their native and denatured conformations while also describing the pressure stability of proteins. A characteristic feature of conformational transitions of globular proteins is a near zero change in volume that is comparable in magnitude with the volume of ionization of biologically relevant buffers. Thus, the impact of buffer ionization on the volume of protein denaturation could be very significant with the potential to affect not only its magnitude but also its sign. To investigate this point quantitatively, we performed pressure perturbation calorimetric (PPC) studies of lysozyme and ribonuclease A at pH 3.0 in four buffers differing in their ionization volumes. Our results identify buffer ionization as an important determinant of protein transition volume that needs to be carefully taken into account. We emphasize that the importance of our results is not limited to PPC measurements but is more general and applies to all volumetric investigations, in particular, extending to the derivation of the pressure-temperature phase diagram of protein stability.

  12. Estimating traffic volume on Wyoming low volume roads using linear and logistic regression methods

    Directory of Open Access Journals (Sweden)

    Dick Apronti

    2016-12-01

    Full Text Available Traffic volume is an important parameter in most transportation planning applications. Low volume roads make up about 69% of road miles in the United States. Estimating traffic on the low volume roads is a cost-effective alternative to taking traffic counts. This is because traditional traffic counts are expensive and impractical for low priority roads. The purpose of this paper is to present the development of two alternative means of cost-effectively estimating traffic volumes for low volume roads in Wyoming and to make recommendations for their implementation. The study methodology involves reviewing existing studies, identifying data sources, and carrying out the model development. The utility of the models developed were then verified by comparing actual traffic volumes to those predicted by the model. The study resulted in two regression models that are inexpensive and easy to implement. The first regression model was a linear regression model that utilized pavement type, access to highways, predominant land use types, and population to estimate traffic volume. In verifying the model, an R2 value of 0.64 and a root mean square error of 73.4% were obtained. The second model was a logistic regression model that identified the level of traffic on roads using five thresholds or levels. The logistic regression model was verified by estimating traffic volume thresholds and determining the percentage of roads that were accurately classified as belonging to the given thresholds. For the five thresholds, the percentage of roads classified correctly ranged from 79% to 88%. In conclusion, the verification of the models indicated both model types to be useful for accurate and cost-effective estimation of traffic volumes for low volume Wyoming roads. The models developed were recommended for use in traffic volume estimations for low volume roads in pavement management and environmental impact assessment studies.

  13. Material properties of large-volume cadmium zinc telluride crystals and their relationship to nuclear detector performance

    Energy Technology Data Exchange (ETDEWEB)

    James, R.B.; Lund, J. [Sandia National Labs., Livermore, CA (United States); Yoon, H. [Sandia National Labs., Livermore, CA (United States)]|[Univ. of California, Los Angeles, CA (United States)] [and others

    1997-09-01

    The material showing the greatest promise today for production of large-volume gamma-ray spectrometers operable at room temperature is cadmium zinc telluride (CZT). Unfortunately, because of deficiencies in the quality of the present material, high-resolution CZT spectrometers have thus far been limited to relatively small dimensions, which makes them inefficient at detecting high photon energies and ineffective for weak radiation signals except in near proximity. To exploit CZT fully, it will be necessary to make substantial improvements in the material quality. Improving the material involves advances in the purity, crystallinity, and control of the electrical compensation mechanism. Sandia National Laboratories, California, in close collaboration with US industry and academia, has initiated efforts to develop a detailed understanding of the underlying material problems limiting the performance of large volume gamma-ray spectrometers and to overcome them through appropriate corrections therein. A variety of analytical and numerical techniques are employed to quantify impurities, compositional and stoichiometric variations, crystallinity, strain, bulk and surface defect states, carrier mobilities and lifetimes, electric field distributions, and contact chemistry. Data from these measurements are correlated with spatial maps of the gamma-ray and alpha particle spectroscopic response to determine improvements in the material purification, crystal growth, detector fabrication, and surface passivation procedures. The results of several analytical techniques will be discussed. The intended accomplishment of this work is to develop a low-cost, high-efficiency CZT spectrometer with an active volume of 5 cm{sup 3} and energy resolution of 1--2% (at 662 keV), which would give the US a new field capability for screening radioactive substances.

  14. LIFAC sorbent injection desulfurization demonstration project. Final report, volume II: Project performance and economics

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-01-01

    This publication discusses the demonstration of the LIFAC sorbent injection technology at Richmond Power and Light`s Whitewater Valley Unit No. 2, performed under the auspices of the U.S. Department of Energy`s (DOE) Clean Coal Technology Program. LIFAC is a sorbent injection technology capable of removing 75 to 85 percent of a power plant`s SO{sub 2} emissions using limestone at calcium to sulfur molar ratios of between 2 and 2.5 to 1. The site of the demonstration is a coal-fired electric utility power plant located in Richmond, Indiana. The project is being conducted by LIFAC North America (LIFAC NA), a joint venture partnership of Tampella Power Corporation and ICF Kaiser Engineers, in cooperation with DOE, RP&L, and Research Institute (EPRI), the State of Indiana, and Black Beauty Coal Company. The purpose of Public Design Report Volume 2: Project Performance and Economics is to consolidate, for public use, the technical efficiency and economy of the LIFAC Process. The report has been prepared pursuant to the Cooperative Agreement No. DE-FC22-90PC90548 between LIFAC NA and the U.S. Department of Energy.

  15. Case mix-adjusted cost of colectomy at low-, middle-, and high-volume academic centers.

    Science.gov (United States)

    Chang, Alex L; Kim, Young; Ertel, Audrey E; Hoehn, Richard S; Wima, Koffi; Abbott, Daniel E; Shah, Shimul A

    2017-05-01

    Efforts to regionalize surgery based on thresholds in procedure volume may have consequences on the cost of health care delivery. This study aims to delineate the relationship between hospital volume, case mix, and variability in the cost of operative intervention using colectomy as the model. All patients undergoing colectomy (n = 90,583) at 183 academic hospitals from 2009-2012 in The University HealthSystems Consortium Database were studied. Patient and procedure details were used to generate a case mix-adjusted predictive model of total direct costs. Observed to expected costs for each center were evaluated between centers based on overall procedure volume. Patient and procedure characteristics were significantly different between volume tertiles. Observed costs at high-volume centers were less than at middle- and low-volume centers. According to our predictive model, high-volume centers cared for a less expensive case mix than middle- and low-volume centers ($12,786 vs $13,236 and $14,497, P case mix at low-volume centers, which may lead to perceived poor performance at these centers. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Brain volume reduction after whole-brain radiotherapy: quantification and prognostic relevance.

    Science.gov (United States)

    Hoffmann, Christian; Distel, Luitpold; Knippen, Stefan; Gryc, Thomas; Schmidt, Manuel Alexander; Fietkau, Rainer; Putz, Florian

    2018-01-22

    Recent studies have questioned the value of adding whole-brain radiotherapy (WBRT) to stereotactic radiosurgery (SRS) for brain metastasis treatment. Neurotoxicity, including radiation-induced brain volume reduction, could be one reason why not all patients benefit from the addition of WBRT. In this study, we quantified brain volume reduction after WBRT and assessed its prognostic significance. Brain volumes of 91 patients with cerebral metastases were measured during a 150-day period after commencing WBRT and were compared with their pretreatment volumes. The average daily relative change in brain volume of each patient, referred to as the "brain volume reduction rate," was calculated. Univariate and multivariate Cox regression analyses were performed to assess the prognostic significance of the brain volume reduction rate, as well as of 3 treatment-related and 9 pretreatment factors. A one-way analysis of variance was used to compare the brain volume reduction rate across recursive partitioning analysis (RPA) classes. On multivariate Cox regression analysis, the brain volume reduction rate was a significant predictor of overall survival after WBRT (P < 0.001), as well as the number of brain metastases (P = 0.002) and age (P = 0.008). Patients with a relatively favorable prognosis (RPA classes 1 and 2) experienced significantly less brain volume decrease after WBRT than patients with a poor prognosis (RPA class 3) (P = 0.001). There was no significant correlation between delivered radiation dose and brain volume reduction rate (P = 0.147). In this retrospective study, a smaller decrease in brain volume after WBRT was an independent predictor of longer overall survival. © The Author(s) 2017. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  17. Exercise testing and hemodynamic performance in healthy elderly persons

    International Nuclear Information System (INIS)

    Hitzhusen, J.C.; Hickler, R.B.; Alpert, J.S.; Doherty, P.W.

    1984-01-01

    To determine the effect of age on cardiovascular performance, 39 healthy elderly men and women, 70 to 83 years old, underwent treadmill thallium-201 exercise perfusion imaging and radionuclide equilibrium angiography at rest and during supine bicycle exercise. Five volunteers who had a positive exercise thallium test response were excluded from the study. Radionuclide left ventricular ejection fraction, regional wall abnormalities, relative cardiac output, stroke volume, end-diastolic volume and end-systolic volume were measured. Seventy-four percent of the subjects maintained or increased their ejection fraction with exercise. With peak exercise, mean end-diastolic volume did not change, end-systolic volume decreased and cardiac output and stroke volume increased. Moreover, in 35% of the subjects, minor regional wall motion abnormalities developed during exercise. There was no significant difference in the response of men and women with regard to these variables. However, more women than men had difficulty performing bicycle ergometry because they had never bicycled before. Subjects who walked daily performed the exercise tests with less anxiety and with a smaller increase in heart rate and systolic blood pressure

  18. Influence of Glass Property Restrictions on Hanford HLW Glass Volume

    International Nuclear Information System (INIS)

    Kim, Dong-Sang; Vienna, John D.

    2001-01-01

    A systematic evaluation of Hanford High-Level Waste (HLW) loading in alkali-alumino-borosilicate glasses was performed. The waste feed compositions used were obtained from current tank waste composition estimates, Hanford's baseline retrieval sequence, and pretreatment processes. The waste feeds were sorted into groups of like composition by cluster analysis. Glass composition optimization was performed on each cluster to meet property and composition constraints while maximizing waste loading. Glass properties were estimated using property models developed for Hanford HLW glasses. The impacts of many constraints on the volume of HLW glass to be produced at Hanford were evaluated. The liquidus temperature, melting temperature, chromium concentration, formation of multiple phases on cooling, and product consistency test response requirements for the glass were varied one- or many-at-a-time and the resultant glass volume was calculated. This study shows clearly that the allowance of crystalline phases in the glass melter can significantly decrease the volume of HLW glass to be produced at Hanford.

  19. Free volume of cyanate resins studied by positron annihilation

    International Nuclear Information System (INIS)

    Suzuki, T.; Oki, Y.; Numajiri, M.; Miura, T.; Kondo, K.; Oshima, N.; Hayashi, T.; Nakamura, H.; Ito, Y.

    1996-01-01

    The polymerization process of bisphenol-A dicyanate (BADCy) has been studied using a positron-annihilation lifetime technique (PAL). The polymerization was conducted at 150 deg C, and the process was followed by PAL. Seven kinds of samples with different curing times were also formed at 150 deg C, and the relation between the period of the curing time and the degree of polymerization was studied. It has been shown that the ο-Ps lifetime increases in samples with a higher polymerization than 85%, which is consistent with measurements of the specific volume of BADCy. (author)

  20. Effect of malaria on placental volume measured using three-dimensional ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Rijken Marcus J

    2012-01-01

    Full Text Available Abstract Background The presence of malaria parasites and histopathological changes in the placenta are associated with a reduction in birth weight, principally due to intrauterine growth restriction. The aim of this study was to examine the feasibility of studying early pregnancy placental volumes using three-dimensional (3D ultrasound in a malaria endemic area, as a small volume in the second trimester may be an indicator of intra-uterine growth restriction and placental insufficiency. Methods Placenta volumes were acquired using a portable ultrasound machine and a 3D ultrasound transducer and estimated using the Virtual Organ Computer-aided AnaLysis (VOCAL image analysis software package. Intra-observer reliability and limits of agreement of the placenta volume measurements were calculated. Polynomial regression models for the mean and standard deviation as a function of gestational age for the placental volumes of uninfected women were created and tested. Based on these equations each measurement was converted into a z -score. The z-scores of the placental volumes of malaria infected and uninfected women were then compared. Results Eighty-four women (uninfected = 65; infected = 19 with a posterior placenta delivered congenitally normal, live born, single babies. The mean placental volumes in the uninfected women were modeled to fit 5th, 10th, 50th, 90th and 95th centiles for 14-24 weeks' gestation. Most placenta volumes in the infected women were below the 50th centile for gestational age; most of those with Plasmodium falciparum were below the 10th centile. The 95% intra-observer limits of agreement for first and second measurements were ± 37.0 mL and ± 25.4 mL at 30 degrees and 15 degrees rotation respectively. Conclusion The new technique of 3D ultrasound volumetry of the placenta may be useful to improve our understanding of the pathophysiological constraints on foetal growth caused by malaria infection in early pregnancy.

  1. Traffic volume and load data measurement using a portable weigh in motion system: A case study

    Directory of Open Access Journals (Sweden)

    Abu N.M. Faruk

    2016-05-01

    Full Text Available Traditionally, traffic loading characteristics are collected for pavement design and performance prediction purposes using permanent roadside weigh-in-motion (WIM stations. However, high installation and maintenance costs associated with these permanent WIM stations dictate that their deployment be mostly limited to major highways, such as the interstate network. Quite often however, pavement damage on high volume rural highways with heavy truck proportions is more severe than anticipated, and there is no effective way of quantifying the traffic loading on these highways. Therefore, this study was conducted to evaluate the potential application of portable WIM systems as a means for bringing the WIM technology to these high volume rural highways. A portable WIM unit was deployed in the Texas overweight corridor in Hidalgo County (Pharr District near the USA-Mexico border on highway FM 1016 for collecting traffic data for a minimum of three weeks in each direction. The collected traffic data were analyzed to generate traffic parameters such as volume, load spectra, and overloading information both in terms of the gross vehicle weight (GVW and axle weight. The computed traffic parameters were successful in partially explaining some of the existing pavement conditions on this highway. Overall, the study findings indicated that the portable WIM unit can be used as a convenient and cost-effective means for collecting reliable traffic information for design, analysis, and monitoring purposes. However, proper in-situ calibration of the portable WIM unit at each site is imperative prior to any real-time traffic data collection. Keywords: Traffic data, Load spectra, Truck overweight, Weigh-in-motion (WIM, Portable WIM, Texas overweight corridor

  2. The Value of Children: A Cross-National Study, Volume Three. Hawaii.

    Science.gov (United States)

    Arnold, Fred; Fawcett, James T.

    The document, one in a series of seven reports from the Value of Children Project, discusses results of the survey in Hawaii. Specifically, the study investigated the social, psychological, and economic costs and benefits associated with having children. The volume is presented in seven chapters. Chapter I describes the background of the study and…

  3. Controlled air incinerator for radioactive waste. Volume II. Engineering design references manual

    International Nuclear Information System (INIS)

    Koenig, R.A.; Draper, W.E.; Newmyer, J.M.; Warner, C.L.

    1982-11-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawings, specifications, calculations, and costs. It aids duplication of the process at other facilities

  4. Age and gender specific normal values of left ventricular mass, volume and function for gradient echo magnetic resonance imaging: a cross sectional study

    International Nuclear Information System (INIS)

    Cain, Peter A; Ahl, Ragnhild; Hedstrom, Erik; Ugander, Martin; Allansdotter-Johnsson, Ase; Friberg, Peter; Arheden, Hakan

    2009-01-01

    Knowledge about age-specific normal values for left ventricular mass (LVM), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) by cardiac magnetic resonance imaging (CMR) is of importance to differentiate between health and disease and to assess the severity of disease. The aims of the study were to determine age and gender specific normal reference values and to explore the normal physiological variation of these parameters from adolescence to late adulthood, in a cross sectional study. Gradient echo CMR was performed at 1.5 T in 96 healthy volunteers (11–81 years, 50 male). Gender-specific analysis of parameters was undertaken in both absolute values and adjusted for body surface area (BSA). Age and gender specific normal ranges for LV volumes, mass and function are presented from the second through the eighth decade of life. LVM, ESV and EDV rose during adolescence and declined in adulthood. SV and EF decreased with age. Compared to adult females, adult males had higher BSA-adjusted values of EDV (p = 0.006) and ESV (p < 0.001), similar SV (p = 0.51) and lower EF (p = 0.014). No gender differences were seen in the youngest, 11–15 year, age range. LV volumes, mass and function vary over a broad age range in healthy individuals. LV volumes and mass both rise in adolescence and decline with age. EF showed a rapid decline in adolescence compared to changes throughout adulthood. These findings demonstrate the need for age and gender specific normal ranges for clinical use

  5. Heart Performance Determination by Visualization in Larval Fishes: Influence of Alternative Models for Heart Shape and Volume

    Directory of Open Access Journals (Sweden)

    Prescilla Perrichon

    2017-07-01

    Full Text Available Understanding cardiac function in developing larval fishes is crucial for assessing their physiological condition and overall health. Cardiac output measurements in transparent fish larvae and other vertebrates have long been made by analyzing videos of the beating heart, and modeling this structure using a conventional simple prolate spheroid shape model. However, the larval fish heart changes shape during early development and subsequent maturation, but no consideration has been made of the effect of different heart geometries on cardiac output estimation. The present study assessed the validity of three different heart models (the “standard” prolate spheroid model as well as a cylinder and cone tip + cylinder model applied to digital images of complete cardiac cycles in larval mahi-mahi and red drum. The inherent error of each model was determined to allow for more precise calculation of stroke volume and cardiac output. The conventional prolate spheroid and cone tip + cylinder models yielded significantly different stroke volume values at 56 hpf in red drum and from 56 to 104 hpf in mahi. End-diastolic and stroke volumes modeled by just a simple cylinder shape were 30–50% higher compared to the conventional prolate spheroid. However, when these values of stroke volume multiplied by heart rate to calculate cardiac output, no significant differences between models emerged because of considerable variability in heart rate. Essentially, the conventional prolate spheroid shape model provides the simplest measurement with lowest variability of stroke volume and cardiac output. However, assessment of heart function—especially if stroke volume is the focus of the study—should consider larval heart shape, with different models being applied on a species-by-species and developmental stage-by-stage basis for best estimation of cardiac output.

  6. Radiotherapy volume delineation using dynamic [18F]-FDG PET/CT imaging in patients with oropharyngeal cancer: a pilot study.

    Science.gov (United States)

    Silvoniemi, Antti; Din, Mueez U; Suilamo, Sami; Shepherd, Tony; Minn, Heikki

    2016-11-01

    Delineation of gross tumour volume in 3D is a critical step in the radiotherapy (RT) treatment planning for oropharyngeal cancer (OPC). Static [ 18 F]-FDG PET/CT imaging has been suggested as a method to improve the reproducibility of tumour delineation, but it suffers from low specificity. We undertook this pilot study in which dynamic features in time-activity curves (TACs) of [ 18 F]-FDG PET/CT images were applied to help the discrimination of tumour from inflammation and adjacent normal tissue. Five patients with OPC underwent dynamic [ 18 F]-FDG PET/CT imaging in treatment position. Voxel-by-voxel analysis was performed to evaluate seven dynamic features developed with the knowledge of differences in glucose metabolism in different tissue types and visual inspection of TACs. The Gaussian mixture model and K-means algorithms were used to evaluate the performance of the dynamic features in discriminating tumour voxels compared to the performance of standardized uptake values obtained from static imaging. Some dynamic features showed a trend towards discrimination of different metabolic areas but lack of consistency means that clinical application is not recommended based on these results alone. Impact of inflammatory tissue remains a problem for volume delineation in RT of OPC, but a simple dynamic imaging protocol proved practicable and enabled simple data analysis techniques that show promise for complementing the information in static uptake values.

  7. The current status of emergency operations at a high-volume cancer center.

    Science.gov (United States)

    Komori, Koji; Kimura, Kenya; Kinoshita, Takashi; Ito, Seiji; Abe, Tetsuya; Senda, Yoshiki; Misawa, Kazunari; Ito, Yuichi; Uemura, Norihisa; Natsume, Seiji; Kawai, Ryosuke; Kawakami, Jiro; Asano, Tomonari; Iwata, Yoshinori; Kurahashi, Shintaro; Tsutsuyama, Masayuki; Shigeyoshi, Itaru; Shimizu, Yasuhiro

    2014-01-01

    This study aimed to assess the pathogenic causes, clinical conditions, surgical procedures, in-hospital mortality, and operative death associated with emergency operations at a high-volume cancer center. Although many reports have described the contents, operative procedures, and prognosis of elective surgeries in high-volume cancer centers, emergency operations have not been studied in sufficient detail. We retrospectively enrolled 28 consecutive patients who underwent emergency surgery. Cases involving operative complications were excluded. The following surgical procedures were performed during emergency operations: closure in 3 cases (10.7%), diversion in 22 cases (78.6%), ileus treatment in 2 cases (7.1%), and hemostasis in 1 case (3.6%). Closure alone was performed only once for peritonitis. Diversion was performed in 17 cases (77.3%) of peritonitis, 4 cases (18.2%) of stenosis of the gastrointestinal tract, and 1 case (4.5%) of bleeding. There was a significant overall difference (P = 0.001). The frequency of emergency operations was very low at a high-volume cancer center. However, the recent shift in treatment approaches toward nonoperative techniques may enhance the status of emergency surgical procedures. The results presented in this study will help prepare for emergency situations and resolve them as quickly and efficiently as possible.

  8. Bare-Hand Volume Cracker for Raw Volume Data Analysis

    Directory of Open Access Journals (Sweden)

    Bireswar Laha

    2016-09-01

    Full Text Available Analysis of raw volume data generated from different scanning technologies faces a variety of challenges, related to search, pattern recognition, spatial understanding, quantitative estimation, and shape description. In a previous study, we found that the Volume Cracker (VC 3D interaction (3DI technique mitigated some of these problems, but this result was from a tethered glove-based system with users analyzing simulated data. Here, we redesigned the VC by using untethered bare-hand interaction with real volume datasets, with a broader aim of adoption of this technique in research labs. We developed symmetric and asymmetric interfaces for the Bare-Hand Volume Cracker (BHVC through design iterations with a biomechanics scientist. We evaluated our asymmetric BHVC technique against standard 2D and widely used 3D interaction techniques with experts analyzing scanned beetle datasets. We found that our BHVC design significantly outperformed the other two techniques. This study contributes a practical 3DI design for scientists, documents lessons learned while redesigning for bare-hand trackers, and provides evidence suggesting that 3D interaction could improve volume data analysis for a variety of visual analysis tasks. Our contribution is in the realm of 3D user interfaces tightly integrated with visualization, for improving the effectiveness of visual analysis of volume datasets. Based on our experience, we also provide some insights into hardware-agnostic principles for design of effective interaction techniques.

  9. Fuzzy Control of Tidal volume, Respiration number and Pressure value

    OpenAIRE

    Hasan Guler; Fikret Ata

    2010-01-01

    In this study, control of tidal volume, respiration number and pressure value which are arrived to patient at mechanical ventilator device which is used in intensive care units were performed with fuzzy logic controller. The aim of this system is to reduce workload of aneshesiologist. By calculating tidal volume, respiration number and pressure value, the error Pe(k) between reference pressure value (Pref) and pressure of gas given ill person (Phasta) and error change rate ;#948;Pe(k) were co...

  10. A study of nasal cavity volume in patients with cleft lip and palate by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Nakano, Kenichi

    1996-01-01

    Nasal cavity volume was studied in 11 patients with cleft lip and palate by magnetic resonance imaging. The areas of horizontal sections of the nasal cavity on the cleft and non-cleft sides were measured with the help of a personal computer and image analyzing software. Nasal cavity volume was determined by integrated volume calculation. The volume of each side was measured before and after cleft lip repair. Before cleft lip repair nasal cavity volume on the non-cleft side was larger than on the cleft side. However there was no significant difference in the volume of the cleft and non-cleft sides after cleft lip repair. (author)

  11. A study of nasal cavity volume in patients with cleft lip and palate by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, Kenichi [Showa Univ., Tokyo (Japan). School of Medicine

    1996-02-01

    Nasal cavity volume was studied in 11 patients with cleft lip and palate by magnetic resonance imaging. The areas of horizontal sections of the nasal cavity on the cleft and non-cleft sides were measured with the help of a personal computer and image analyzing software. Nasal cavity volume was determined by integrated volume calculation. The volume of each side was measured before and after cleft lip repair. Before cleft lip repair nasal cavity volume on the non-cleft side was larger than on the cleft side. However there was no significant difference in the volume of the cleft and non-cleft sides after cleft lip repair. (author)

  12. Gd-DTPA and volume acquisitions in brain and spine tumors

    International Nuclear Information System (INIS)

    Ross, J.S.; Masaryk, T.J.; Modic, M.T.; Clampitt, M.

    1988-01-01

    Seventeen cases referred for evaluation of suspected neoplasms were studied with anisotropic three-dimensional fast low-angle shot imaging (30-60/9-14/50) with partitions of 1.5-3 mm before and after 0.1 mmol/kg of Gd-DTPA (Berlex Laboratories). Multiplanar reconstructions were performed on a Kontron work station. Sagittal and axial T1-weighted two-dimensional spin-echo (SE) sequences were acquired for comparison. Diagnoses included normal (N = 3), brain neoplasms (N = 7), spine neoplasms (N = 6), and brain inflammation (N = 1). Volume studies were of sufficient quality to allow reconstructions in 12 cases and were comparable diagnostically with two-dimensional SE images. Advantages of the three-dimensional technique were capacity to reconstruct any plane, decreased partial volume averaging, and a shorter examination time. Tissue contrast appeared equivalent. In five patients the examinations were inferior to SE studies because of motion and lack of contrast between vessels and enhancing regions. Paramagnetic contrast increases the sensitivity of volume studies in the detection of disease

  13. Associations between regional brain volumes at term-equivalent age and development at 2 years of age in preterm children

    International Nuclear Information System (INIS)

    Lind, Annika; Parkkola, Riitta; Lehtonen, Liisa; Maunu, Jonna; Lapinleimu, Helena; Munck, Petriina; Haataja, Leena

    2011-01-01

    Altered brain volumes and associations between volumes and developmental outcomes have been reported in prematurely born children. To assess which regional brain volumes are different in very low birth weight (VLBW) children without neurodevelopmental impairments ([NDI] cerebral palsy, hearing loss, blindness and significantly delayed cognitive performance) compared with VLBW children with NDI, and to evaluate the association between regional brain volumes at term-equivalent age and cognitive development and neurological performance at a corrected age of 2 years. The study group consisted of a regional cohort of 164 VLBW children, divided into one group of children without NDI (n = 148) and one group of children with NDI (n = 16). Brain (MRI) was performed at term-equivalent age, from which brain volumes were manually analysed. Cognitive development was assessed with the Bayley Scales of Infant Development II (BSID-II), and neurological performance with the Hammersmith Infant Neurological Examination at the corrected age of 2 years. The volumes of total brain tissue, cerebrum, frontal lobes, basal ganglia and thalami, and cerebellum were significantly smaller, and the volume of the ventricles significantly larger, in the children with NDI than in those without NDI. Even in children without NDI, a smaller cerebellar volume was significantly correlated with poor neurological performance at 2 years of corrected age. Volumetric analysis at brain MRI can provide an additional parameter for early prediction of outcome in VLBW children. (orig.)

  14. Associations between regional brain volumes at term-equivalent age and development at 2 years of age in preterm children

    Energy Technology Data Exchange (ETDEWEB)

    Lind, Annika [Turku University Hospital, Department of Pediatrics, Turku (Finland); Aabo Akademi University, Department of Psychology, Turku (Finland); Parkkola, Riitta [University of Turku and Turku University Hospital, Department of Radiology and Turku PET Center, PO Box 52, Turku (Finland); Lehtonen, Liisa; Maunu, Jonna; Lapinleimu, Helena [University of Turku and Turku University Hospital, Department of Pediatrics, Turku (Finland); Munck, Petriina [Turku University Hospital, Department of Pediatrics, Turku (Finland); University of Turku, Department of Psychology, Turku (Finland); Haataja, Leena [University of Turku and Turku University Hospital, Department of Pediatric Neurology, Turku (Finland)

    2011-08-15

    Altered brain volumes and associations between volumes and developmental outcomes have been reported in prematurely born children. To assess which regional brain volumes are different in very low birth weight (VLBW) children without neurodevelopmental impairments ([NDI] cerebral palsy, hearing loss, blindness and significantly delayed cognitive performance) compared with VLBW children with NDI, and to evaluate the association between regional brain volumes at term-equivalent age and cognitive development and neurological performance at a corrected age of 2 years. The study group consisted of a regional cohort of 164 VLBW children, divided into one group of children without NDI (n = 148) and one group of children with NDI (n = 16). Brain (MRI) was performed at term-equivalent age, from which brain volumes were manually analysed. Cognitive development was assessed with the Bayley Scales of Infant Development II (BSID-II), and neurological performance with the Hammersmith Infant Neurological Examination at the corrected age of 2 years. The volumes of total brain tissue, cerebrum, frontal lobes, basal ganglia and thalami, and cerebellum were significantly smaller, and the volume of the ventricles significantly larger, in the children with NDI than in those without NDI. Even in children without NDI, a smaller cerebellar volume was significantly correlated with poor neurological performance at 2 years of corrected age. Volumetric analysis at brain MRI can provide an additional parameter for early prediction of outcome in VLBW children. (orig.)

  15. Comparative study of the endoscope-based bevelled and volume fiber-optic Raman probes for optical diagnosis of gastric dysplasia in vivo at endoscopy.

    Science.gov (United States)

    Wang, Jianfeng; Lin, Kan; Zheng, Wei; Ho, Khek Yu; Teh, Ming; Yeoh, Khay Guan; Huang, Zhiwei

    2015-11-01

    This study aims to compare the diagnostic performance of the two different endoscope-based fiber-optic Raman probe designs (i.e., bevelled and volume Raman probes) for real-time, in vivo detection of gastric dysplasia at endoscopy. To conduct the clinical comparison, a total of 1,050 in vivo tissue Raman spectra (normal: n = 864; dysplasia: n = 186) were acquired from 66 gastric patients (normal: n = 48; dysplasia: n = 18) by using bevelled Raman probe, while a total of 1,913 in vivo tissue Raman spectra (normal: n = 1,786; dysplasia: n = 127) were acquired from 98 gastric patients (normal: n = 87; dysplasia: n = 11) by using volume Raman probe. The bevelled Raman probe provides approximately twofold improvements in tissue Raman-to-autofluorescence intensity ratios as compared to the use of volume Raman probe. Partial least squares discriminant analysis together with leave-one patient-out cross-validation on in vivo tissue Raman spectra acquired yields a diagnostic accuracy of 93.0 % (sensitivity of 92.5 %; specificity of 93.1 %) for differentiating gastric dysplasia from normal gastric tissue by using the bevelled fiber-optic Raman probe, which is superior to the diagnostic performance (accuracy of 88.4 %; sensitivity of 85.8 %; specificity of 88.6 %) by using the volume Raman probe. This work demonstrates that the Raman spectroscopic technique coupled with bevelled fiber-optic Raman probe has great potential to enhance in vivo diagnosis of gastric precancer and early cancer at endoscopy. Graphical Abstract Comparison of in vivo gastric tissue Raman spectra acquired by using bevelled and volume fiber-optic Raman probes.

  16. Sensitivity Analysis of Wavelet Neural Network Model for Short-Term Traffic Volume Prediction

    Directory of Open Access Journals (Sweden)

    Jinxing Shen

    2013-01-01

    Full Text Available In order to achieve a more accurate and robust traffic volume prediction model, the sensitivity of wavelet neural network model (WNNM is analyzed in this study. Based on real loop detector data which is provided by traffic police detachment of Maanshan, WNNM is discussed with different numbers of input neurons, different number of hidden neurons, and traffic volume for different time intervals. The test results show that the performance of WNNM depends heavily on network parameters and time interval of traffic volume. In addition, the WNNM with 4 input neurons and 6 hidden neurons is the optimal predictor with more accuracy, stability, and adaptability. At the same time, a much better prediction record will be achieved with the time interval of traffic volume are 15 minutes. In addition, the optimized WNNM is compared with the widely used back-propagation neural network (BPNN. The comparison results indicated that WNNM produce much lower values of MAE, MAPE, and VAPE than BPNN, which proves that WNNM performs better on short-term traffic volume prediction.

  17. Theoretical study for volume changes associated with the helix-coil transition of peptides.

    Science.gov (United States)

    Imai, T; Harano, Y; Kovalenko, A; Hirata, F

    2001-12-01

    We calculate the partial molar volumes and their changes associated with the coil(extended)-to-helix transition of two types of peptide, glycine-oligomer and glutamic acid-oligomer, in aqueous solutions by using the Kirkwood-Buff solution theory coupled with the three-dimensional reference interaction site model (3D-RISM) theory. The volume changes associated with the transition are small and positive. The volume is analyzed by decomposing it into five contributions following the procedure proposed by Chalikian and Breslauer: the ideal volume, the van der Waals volume, the void volume, the thermal volume, and the interaction volume. The ideal volumes and the van der Waals volumes do not change appreciably upon the transition. In the both cases of glycine-peptide and glutamic acid-peptide, the changes in the void volumes are positive, while those in the thermal volumes are negative, and tend to balance those in the void volumes. The change in the interaction volume of glycine-peptide does not significantly contribute, while that of glutamic acid-peptide makes a negative contribution. Copyright 2001 John Wiley & Sons, Inc. Biopolymers 59: 512-519, 2001

  18. Evaluation of volume vascularization index and flow index: A phantom study

    NARCIS (Netherlands)

    M.J.N.C. Schulten-Wijman; P.C. Struijk (Pieter); C.A. Brezinka (Christoph); N. de Jong (Nico); R.P.M. Steegers-Theunissen (Régine)

    2008-01-01

    textabstractObjectives Three-dimensional (3D) power Doppler ultrasonography provides indices to quantify moving blood within a volume of interest (e.g. ovary, endometrium, tumor or placenta). The purpose of this study was to determine the influence of ultrasound instrument settings on

  19. Predicting memory performance in normal ageing using different measures of hippocampal size

    International Nuclear Information System (INIS)

    Lye, T.C.; Creasey, H.; Kril, J.J.; Grayson, D.A.; Piguet, O.; Bennett, H.P.; Ridley, L.J.; Broe, G.A.

    2006-01-01

    A number of different methods have been employed to correct hippocampal volumes for individual variation in head size. Researchers have previously used qualitative visual inspection to gauge hippocampal atrophy. The purpose of this study was to determine the best measure(s) of hippocampal size for predicting memory functioning in 102 community-dwelling individuals over 80 years of age. Hippocampal size was estimated using magnetic resonance imaging (MRI) volumetry and qualitative visual assessment. Right and left hippocampal volumes were adjusted by three different estimates of head size: total intracranial volume (TICV), whole-brain volume including ventricles (WB+V) and a more refined measure of whole-brain volume with ventricles extracted (WB). We compared the relative efficacy of these three volumetric adjustment methods and visual ratings of hippocampal size in predicting memory performance using linear regression. All four measures of hippocampal size were significant predictors of memory performance. TICV-adjusted volumes performed most poorly in accounting for variance in memory scores. Hippocampal volumes adjusted by either measure of whole-brain volume performed equally well, although qualitative visual ratings of the hippocampus were at least as effective as the volumetric measures in predicting memory performance in community-dwelling individuals in the ninth or tenth decade of life. (orig.)

  20. Continuous modelling study of numerical volumes - Applications to the visualization of anatomical structures

    International Nuclear Information System (INIS)

    Goret, C.

    1990-12-01

    Several technics of imaging (IRM, image scanners, tomoscintigraphy, echography) give numerical informations presented by means of a stack of parallel cross-sectional images. Since many years, 3-D mathematical tools have been developed and allow the 3 D images synthesis of surfaces. In first part, we give the technics of numerical volume exploitation and their medical applications to diagnosis and therapy. The second part is about a continuous modelling of the volume with a tensor product of cubic splines. We study the characteristics of this representation and its clinical validation. Finally, we treat of the problem of surface visualization of objects contained in the volume. The results show the interest of this model and allow to propose specifications for 3-D workstation realization [fr

  1. [Evaluation of tidal volume delivered by ventilators during volume-controlled ventilation].

    Science.gov (United States)

    Zhou, Juan; Yan, Yong; Cao, Desen

    2014-12-01

    To study the ways which ensure the delivery of enough tidal volume to patients under various conditions close to the demand of the physician. The volume control ventilation model was chosen, and the simulation lung type was active servo lung ASL 5000 or Michigan lung 1601. The air resistance, air compliance and lung type in simulation lungs were set. The tidal volume was obtained from flow analyzer PF 300. At the same tidal volume, the displaying values of tidal volume of E5, Servo i, Evital 4, and Evital XL ventilators with different lung types of patient, compliance of gas piping, leakage, gas types, etc. were evaluated. With the same setting tidal volume of a same ventilator, the tidal volume delivered to patients was different with different lung types of patient, compliance of gas piping, leakage, gas types, etc. Reducing compliance and increasing resistance of the patient lungs caused high peak airway pressure, the tidal volume was lost in gas piping, and the tidal volume be delivered to the patient lungs was decreased. If the ventilator did not compensate to leakage, the tidal volume delivered to the patient lungs was decreased. When the setting gas type of ventilator did not coincide with that applying to the patient, the tidal volume be delivered to the patient lungs might be different with the setting tidal volume of ventilator. To ensure the delivery of enough tidal volume to patients close to the demand of the physician, containable factors such as the compliance of gas piping, leakage, and gas types should be controlled.

  2. Impact of institutional volume and experience with CT interpretation on sizing of transcatheter aortic valves: A multicenter retrospective study

    International Nuclear Information System (INIS)

    Verma, Divya Ratan; Pershad, Yash; Pershad, Ashish; Fang, Kenith; Gellert, George; Morris, Michael F.

    2016-01-01

    Background: Computed tomography (CT) has become the standard imaging modality for pre-procedural aortic annular sizing prior to transcatheter aortic valve replacement (TAVR). We hypothesized that the accuracy of CT derived annular measurements would be greater at sites with higher TAVR procedural volume. Methods: Within a large integrated health system, TAVR was performed at low ( 75 cases). 181 patients underwent TAVR with a Sapien XT transcatheter heart valve (THV). Two blinded experienced readers independently remeasured the annulus on CT and compared their measurements to site reported measurements. Hypothetical THV sizes were chosen based on measurements from site CT reports and independent readers’ measurements, and compared to the implanted THV size. Results: Correlation between site reported measurements and independent readers measurements of mean annulus size varied between low-volume (r = 0.31, p = 0.18), intermediate-volume (r = 0.34, p = 0.01), and high-volume sites (r = 0.96, p < 0.01). On multivariate analysis, interpretation of ≥20 CT scans (OR 0.29; 95% CI 0.03–0.81; p 0.02) and high-volume site (OR 0.16; 95% CI 0.10–0.82; p 0.02) were associated with reduced mismatch between the site predicted THV size and independent readers predicted THV size. Mismatch between site predicted THV size and implanted THV size was associated with a worse 30-day composite of mortality, dialysis-dependent renal failure, cerebrovascular accident, new permanent pacemaker, and hospital readmission (55.3 vs. 38.7%; p = 0.05). Conclusions: Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. These findings should be confirmed in larger, prospective studies. - Highlights: • Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. • CT readers with experience interpreting ≥20 pre-TAVR CT scans had significantly improved accuracy in identifying the annulus.

  3. Free volume study on the miscibility of PEEK/PEI blend using positron annihilation and dynamic mechanical thermal analysis

    International Nuclear Information System (INIS)

    Ramani, R; Alam, S

    2015-01-01

    High performance polymer blend of poly(ether ether ketone) (PEEK) and poly(ether imide) (PEI) was examined for their free volume behaviour using positron annihilation lifetime spectroscopy and dynamic mechanical thermal analysis methods. The fractional free volume obtained from PALS shows a negative deviation from linear additivity rule implying good miscibility between PEEK and PEI. The dynamic modulus and loss tangent were obtained for the blends at three different frequencies 1, 10 and 100 Hz at temperatures close to and above their glass transition temperature. Applying Time-Temperature-Superposition (TTS) principle to the DMTA results, master curves were obtained at a reference temperature T o and the WLF coefficients c 0 1 and c 0 2 were evaluated. Both the methods give similar results for the dependence of fractional free volume on PEI content in this blend. The results reveal that free volume plays an important role in determining the visco-elastic properties in miscible polymer blends. (paper)

  4. Right Hemisphere Grey Matter Volume and Language Functions in Stroke Aphasia

    Directory of Open Access Journals (Sweden)

    Sladjana Lukic

    2017-01-01

    Full Text Available The role of the right hemisphere (RH in recovery from aphasia is incompletely understood. The present study quantified RH grey matter (GM volume in individuals with chronic stroke-induced aphasia and cognitively healthy people using voxel-based morphometry. We compared group differences in GM volume in the entire RH and in RH regions-of-interest. Given that lesion site is a critical source of heterogeneity associated with poststroke language ability, we used voxel-based lesion symptom mapping (VLSM to examine the relation between lesion site and language performance in the aphasic participants. Finally, using results derived from the VLSM as a covariate, we evaluated the relation between GM volume in the RH and language ability across domains, including comprehension and production processes both at the word and sentence levels and across spoken and written modalities. Between-subject comparisons showed that GM volume in the RH SMA was reduced in the aphasic group compared to the healthy controls. We also found that, for the aphasic group, increased RH volume in the MTG and the SMA was associated with better language comprehension and production scores, respectively. These data suggest that the RH may support functions previously performed by LH regions and have important implications for understanding poststroke reorganization.

  5. Preliminary study on functional performance of compound type multistage safety injection tank

    International Nuclear Information System (INIS)

    Bae, Youngmin; Kim, Young In; Kim, Keung Koo

    2015-01-01

    Highlights: • Functional performance of compound type multistage safety injection tanks is studied. • Effects of key design parameters are scrutinized. • Distinctive flow features in compound type safety injection tanks are explored. - Abstract: A parametric study is carried out to evaluate the functional performance of a compound type multistage safety injection tank that would be considered one of the components for the passive safety injection systems in nuclear power plants. The effects of key design parameters such as the initial volume fraction and charging pressure of gas, tank elevation, vertical location of a sparger, resistance coefficient, and operating condition on the injection flow rate are scrutinized along with a discussion of the relevant flow features. The obtained results indicate that the compound type multistage safety injection tank can effectively control the injection flow rate in a passive manner, by switching the driving force for the safety injection from gas pressure to gravity during the refill and reflood phases, respectively

  6. A Pilot Study on the Feasibility of Interventional Lung Volume Reduction

    International Nuclear Information System (INIS)

    Wang Wansheng; Dong Yonghua; Liu Bin; Zhu Chi; Yu Yongqiang

    2008-01-01

    The objective of this study was to evaluate the feasibility and safety of lung volume reduction by transbronchial alcohol and lipiodol suspension infusion with the aid of balloon-tipped catheter occlusion. Twenty-six healthy adult rabbits were divided into four treatment groups: alcohol and lipiodol suspension infusion (n = 8), lipiodol infusion (n = 8), alcohol infusion (n = 5), or bronchial lumen occlusion (n = 5). After selective lobar or segmental bronchial catheterization using a balloon-tipped occlusion catheter, the corresponding drug infusion was performed. Bone cement was used to occlude the bronchial lumen in the occlusion group. The animals were followed up for 10 weeks by chest X-ray and computed tomography (CT), and then the whole lungs were harvested for histological examination. Alcohol and lipiodol suspension or lipiodol could be stably retained in alveoli in the first two groups based on chest X-ray and CT, but obvious collapse only occurred in the group receiving alcohol and lipiodol suspension or the bronchial lumen occlusion group. Histological examination revealed damage and disruption of the alveolar epithelium and fibrosis in related lung tissue in the group receiving alcohol and lipiodol suspension. Similar changes were seen in the bronchial lumen occlusion group, apart from obvious marginal emphysema of the target areas in two animals. Interstitial pneumonia and dilated alveoli existed in some tissue in target areas in the lipiodol group, in which pulmonary fibrosis obliterating alveoli also occurred. Chronic alveolitis and pleural adhesion in target areas occurred in the group infused with alcohol alone, whereas visceral pleura of the other three groups was regular and no pleural effusion or adhesion was found. Alcohol and lipiodol suspension that is stably retained in alveoli can result in significant lung volume reduction. Through alcohol and lipiodol suspension infusion, obstructive emphysema or pneumonia arising from bronchial lumen

  7. A survey of electric and hybrid vehicles simulation programs. Volume 2: Questionnaire responses

    Science.gov (United States)

    Bevan, J.; Heimburger, D. A.; Metcalfe, M. A.

    1978-01-01

    The data received in a survey conducted within the United States to determine the extent of development and capabilities of automotive performance simulation programs suitable for electric and hybrid vehicle studies are presented. The survey was conducted for the Department of Energy by NASA's Jet Propulsion Laboratory. Volume 1 of this report summarizes and discusses the results contained in Volume 2.

  8. Measurement of synovial fluid volume using urea.

    Science.gov (United States)

    Kraus, V B; Stabler, T V; Kong, S Y; Varju, G; McDaniel, G

    2007-10-01

    To examine the utility of using urea concentrations for determining Synovial Fluid (SF) joint volume in effused and non-effused joints. Knee joint SF was aspirated from 159 human study participants with symptomatic osteoarthritis of at least one knee either directly (165 knees) or by lavage (110 knees). Serum was obtained immediately prior to SF aspiration. Participants were asked to rate individual knee pain, aching or stiffness. SF and serum urea levels were determined using a specific enzymatic method run on an automated CMA600 analyzer. Cell counts were performed on direct SF aspirates when volume permitted. The formula for calculating SF joint volume was as follows: V(j)=C(D)(V(I))/(C-C(D)) with V(j)=volume of SF in entire joint, C(D)=concentration of urea in diluted (lavage) SF, V(I)=volume of saline injected into joint, and C=concentration of urea in undiluted (neat) SF derived below where C=0.897(C(S)) and C(s)=concentration of urea in serum. There was an excellent correlation (r(2)=0.8588) between SF and serum urea in the direct aspirates with a ratio of 0.897 (SF/serum). Neither urea levels nor the SF/serum ratio showed any correlation with Kellgren Lawrence (KL) grade, or cell count. While urea levels increased with age there was no change in the ratio. Intraarticular SF volumes calculated for the lavaged knees ranged from 0.555 to 71.71ml with a median volume of 3.048ml. There was no correlation of SF volume to KL grade but there was a positive correlation (P=0.001) between SF volume and self-reported individual knee pain. Our urea results for direct aspirates indicate an equilibrium state between serum and SF with regard to the water fraction. This equilibrium exists regardless of disease status (KL grade), inflammation (cell count), or age, making it possible to calculate intraarticular volume of lavaged joints based upon this urea method. Most of the joint volumes we calculated fell within the previously reported range for normal knees of 0.5-4.0ml

  9. Multicenter Study of Brain Volume Abnormalities in Children and Adolescent-Onset Psychosis

    Science.gov (United States)

    Reig, Santiago; Parellada, Mara; Castro-Fornieles, Josefina; Janssen, Joost; Moreno, Dolores; Baeza, Inmaculada; Bargalló, Nuria; González-Pinto, Ana; Graell, Montserrat; Ortuño, Felipe; Otero, Soraya; Arango, Celso; Desco, Manuel

    2011-01-01

    The goal of the study is to determine the extent of structural brain abnormalities in a multicenter sample of children and adolescents with a recent-onset first episode of psychosis (FEP), compared with a sample of healthy controls. Total brain and lobar volumes and those of gray matter (GM), white matter, and cerebrospinal fluid (CSF) were measured in 92 patients with a FEP and in 94 controls, matched for age, gender, and years of education. Male patients (n = 64) showed several significant differences when compared with controls (n = 61). GM volume in male patients was reduced in the whole brain and in frontal and parietal lobes compared with controls. Total CSF volume and frontal, temporal, and right parietal CSF volumes were also increased in male patients. Within patients, those with a further diagnosis of “schizophrenia” or “other psychosis” showed a pattern similar to the group of all patients relative to controls. However, bipolar patients showed fewer differences relative to controls. In female patients, only the schizophrenia group showed differences relative to controls, in frontal CSF. GM deficit in male patients with a first episode correlated with negative symptoms. Our study suggests that at least part of the GM deficit in children and adolescent-onset schizophrenia and in other psychosis occurs before onset of the first positive symptoms and that, contrary to what has been shown in children-onset schizophrenia, frontal GM deficits are probably present from the first appearance of positive symptoms in children and adolescents. PMID:20478821

  10. A PRACTICAL MODEL OF LOW-VOLUME HIGH-INTENSITY INTERVAL TRAINING INDUCES PERFORMANCE AND METABOLIC ADAPTATIONS THAT RESEMBLE 'ALL-OUT' SPRINT INTERVAL TRAINING

    Directory of Open Access Journals (Sweden)

    Mahdi Bayati

    2011-09-01

    Full Text Available Recently, a novel type of high-intensity interval training known as sprint interval training has demonstrated increases in aerobic and anaerobic performance with very low time commitment. However, this type of training program is unpractical for general populations. The present study compared the impact of a low-volume high-intensity interval training to a "all-out" sprint interval training. Twenty-four active young males were recruited and randomized into three groups: (G1: 3-5 cycling bouts × 30-s all-out with 4 min recovery; G2: 6- 10 cycling bouts × 125% Pmax with 2 min recovery and a non-trained control group. They all performed a VO2max test, a time to exhaustion at Pmax (Tmax and a Wingate test before and after the intervention. Capillary blood lactate was taken at rest, 3, and 20 min after the Wingate trial. Training was performed 3 sessions per week for 4 weeks. In G1, significant improvements (p < 0.05 following training were found in VO2max (9.6%, power at VO2max (12.8%, Tmax (48.4%, peak power output (10.3% and mean power output (17.1%. In G2, significant improvements following training were found in VO2max (9.7%, power at VO2max (16.1%, Tmax (54.2%, peak power output (7.4%; p < 0.05, but mean power output did not change significantly. Blood lactate recovery (20th min significantly decreased in G1 and G2 when compared with pre-testing and the CON group (p < 0.05. In conclusion, the results of the current study agree with earlier work demonstrating the effectiveness of 30-s all-out training program to aerobic and anaerobic adaptations. Of substantial interest is that the low volume high intensity training provides similar results but involves only half the intensity with double the repetitions

  11. Experimental study of DI diesel engine performance using biodiesel blends with kerosene

    Energy Technology Data Exchange (ETDEWEB)

    Azad, A.K.; Ameer Uddin, S.M.; Alam, M.M. [Department of Mechanical Engineering, Bangladesh University of Engineering and Technology, Dhaka-1000 (Bangladesh)

    2013-07-01

    The experimental investigation offers a comprehensive study of DI diesel engine performance using bio-diesel from mustard oil blends with kerosene. The vegetable oil without trans-esterification reaction have been blended with kerosene oil by volume in some percentage like 20%, 30%, 40% and 50% which have been named as M20 (20% mustard, 80% kerosene), M30 (30% mustard, 70% kerosene), M40 (40% mustard, 60% kerosene) and M50 (50% mustard, 50% kerosene). The properties of the bio-fuel blended with kerosene have been tested in the laboratories with maintaining different ASTM standards. Then a four stroke, single cylinder, direct injection diesel engine has been mounted on the dynamometer bed for testing the performance of the engine using the bio-diesel blends. Several engine parameters like bsfc, bhp, break mean effective pressure, exhaust gas temperature, lube oil temperature, sound level etc. have been determined. A comparison has been made for engine performance of different bio-diesel blends with kerosene with the engine performance of diesel fuel.

  12. Study on the micro direct ethanol fuel cell (Micro-DEFC) performance

    Science.gov (United States)

    Saisirirat, Penyarat; Joommanee, Bordindech

    2018-01-01

    The direct ethanol fuel cell (DEFC) is selected for this research. DEFC uses ethanol in the fuel cell instead of the more toxic methanol. Ethanol is more attractive than methanol by many reasons. Ethanol is a hydrogen-rich liquid and it has a higher specific energy (8.0 kWh/kg) compared to that of methanol (6.1 kWh/kg). Ethanol can be obtained in great quantity from biomass through a fermentation process from renewable resources such as sugar cane, wheat, corn, and even straw. The use of ethanol would also overcome both the storage and infrastructure challenge of hydrogen for fuel cell applications. The experimental apparatus on the micro direct ethanol fuel cell for measuring the cell performance has been set for this research. The objective is to study the micro direct ethanol fuel cell performance for applying with the portable electronic devices. The cell performance is specified in the terms of cell voltage, cell current and power of the cell at room operating temperature and 1 atm for the pressure and also includes the ethanol fuel consumption. The effect of operating temperature change on the electrical production performance is also studied. The steady-state time for collecting each data value is about 5-10 minutes. The results show that with the increase of concentrations of ethanol by volume, the reactant concentration at the reaction sites increases so the electrochemical rate also increases but when it reaches the saturated point the performance gradually drops.

  13. The relationship of hospital charges and volume to surgical site infection after total hip replacement.

    Science.gov (United States)

    Boas, Rebecca; Ensor, Kelsey; Qian, Edward; Hutzler, Lorraine; Slover, James; Bosco, Joseph

    2015-05-01

    The purpose of this study was to analyze the effect of hospital volume and charges on the rate of surgical site infections for total hip replacements (THRs) in New York State (NYS). In NYS, higher volume hospitals have higher charges after THR. The study team analyzed 93,620 hip replacements performed in NYS between 2008 and 2011. Hospital charges increased significantly from $43,713 in 2008 to $50,652 in 2011 (P<.01). Compared with lower volume hospitals, patients who underwent THR at the highest volume hospitals had significantly lower surgical site infection rates (P=.003) and higher total hospital charges (P<.0001). The study team found that in the highest volume hospitals, preventing one surgical site infection was associated with $1.6 million dollars in increased charges. © 2014 by the American College of Medical Quality.

  14. A comparison of case volumes among urologic surgeons identified on an industry-sponsored website to an all provider peer group.

    Science.gov (United States)

    See, William A; Jacobson, Kenneth; Derus, Sue; Langenstroer, Peter

    2014-11-01

    Industry-sponsored websites for robotic surgery direct to surgeons listed as performing specific robotic surgical procedures. The purpose of this study was to compare average annual, surgeon-specific, case volumes for those procedures for which they were listed as performing on the commercial website with the volumes of all providers performing these same procedures across a defined geographic region. A list of providers within the state of Wisconsin cited as performing specific urologic procedures was obtained through the Intuitive Surgical website 〈http://www.davincisurgery.com/da-vinci-urology/〉. Surgeon-specific annual case volumes from 2009 to 2013 for these same cases were obtained for all Wisconsin providers through DataBay Resources (Warrendale, PA) based on International classification of diseases-9 codes. Procedural activity was rank ordered, and surgeons were placed in "volume deciles" derived from the total annual number of cases performed by all surgeons. The distribution of commercially listed surgeon volumes, both 5-year average and most recent year, was compared with the average and 2013 volumes of all surgeons performing a specific procedure. A total of 35 individual urologic surgeons listed as performing robotic surgery in Wisconsin were identified through a "search" using the Intuitive Surgical website. Specific procedure analysis returned 5, 12, 9, and 15 surgeon names for cystectomy, partial nephrectomy, radical nephrectomy, and prostatectomy, respectively. This compared with the total number of surgeons who had performed the listed procedure in Wisconsin at least 1 time during the prior 5 years of 123, 153, 242, and 165, respectively. When distributed by surgeon-volume deciles, surgeons listed on industry-sponsored sites varied widely in their respective volume decile. More than half of site-listed, procedure-specific surgeons fell below the fifth decile for surgeon volume. Data analysis based solely on 2013 case volumes had no effect on

  15. A checkpoint compression study for high-performance computing systems

    Energy Technology Data Exchange (ETDEWEB)

    Ibtesham, Dewan [Univ. of New Mexico, Albuquerque, NM (United States). Dept. of Computer Science; Ferreira, Kurt B. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Scalable System Software Dept.; Arnold, Dorian [Univ. of New Mexico, Albuquerque, NM (United States). Dept. of Computer Science

    2015-02-17

    As high-performance computing systems continue to increase in size and complexity, higher failure rates and increased overheads for checkpoint/restart (CR) protocols have raised concerns about the practical viability of CR protocols for future systems. Previously, compression has proven to be a viable approach for reducing checkpoint data volumes and, thereby, reducing CR protocol overhead leading to improved application performance. In this article, we further explore compression-based CR optimization by exploring its baseline performance and scaling properties, evaluating whether improved compression algorithms might lead to even better application performance and comparing checkpoint compression against and alongside other software- and hardware-based optimizations. Our results highlights are: (1) compression is a very viable CR optimization; (2) generic, text-based compression algorithms appear to perform near optimally for checkpoint data compression and faster compression algorithms will not lead to better application performance; (3) compression-based optimizations fare well against and alongside other software-based optimizations; and (4) while hardware-based optimizations outperform software-based ones, they are not as cost effective.

  16. Evaluation of fourier transform profilometry performance: quantitative waste volume determination under simulated Hanford waste tank conditions

    International Nuclear Information System (INIS)

    Jang, Ping-Rey; Leone, Teresa; Long, Zhiling; Mott, Melissa A.; Perry Norton, O.; Okhuysen, Walter P.; Monts, David L.

    2007-01-01

    The Hanford Site is currently in the process of an extensive effort to empty and close its radioactive single-shell and double-shell waste storage tanks. Before this can be accomplished, it is necessary to know how much residual material is left in a given waste tank and the chemical makeup of the residue. The objective of Mississippi State University's Institute for Clean Energy Technology's (ICET) efforts is to develop, fabricate, and deploy inspection tools for the Hanford waste tanks that will (1) be remotely operable; (2) provide quantitative information on the amount of wastes remaining; and (3) provide information on the spatial distribution of chemical and radioactive species of interest. A collaborative arrangement has been established with the Hanford Site to develop probe-based inspection systems for deployment in the waste tanks. ICET is currently developing an in-tank inspection system based on Fourier Transform Profilometry, FTP. FTP is a non-contact, 3-D shape measurement technique. By projecting a fringe pattern onto a target surface and observing its deformation due to surface irregularities from a different view angle, FTP is capable of determining the height (depth) distribution (and hence volume distribution) of the target surface, thus reproducing the profile of the target accurately under a wide variety of conditions. Hence FTP has the potential to be utilized for quantitative determination of residual wastes within Hanford waste tanks. We have completed a preliminary performance evaluation of FTP in order to document the accuracy, precision, and operator dependence (minimal) of FTP under conditions similar to those that can be expected to pertain within Hanford waste tanks. Based on a Hanford C-200 series tank with camera access through a riser with significant offset relative to the centerline, we devised a testing methodology that encompassed a range of obstacles likely to be encountered 'in tank'. These test objects were inspected by use

  17. Retrospective study of renal distribution volume with DTPA-99mTc: performance of single plasma method for glomerular filtration rate estimation

    International Nuclear Information System (INIS)

    Legendre, J.M.; Cledes, J.; Morin, J.F.; Morin, P.P.

    1997-01-01

    169 glomerular filtration rate (GFR) measurements, performed in clinical practice, were analysed for estimation of GFR by several common methods. In one half of patients, we observed that early (2-3-4 hours) and tardive (3-4-5 hours three point plasma methods were highly correlated, r = 0,998 (n = 82). Even if regression line significantly differed from identify, differences between methods were low (-6, 1 to + 4,4 mL/min/1,73 m 2 ). Method with urinary collection was also correlated to plasma methods (r = 0,920 in both cases). Plasma based mean values were higher than that for urinary by 3,6 mL/min/1,73 m 2 (2-3-4 hours) and 3, 1 (3-4-5 hours). Using plasma GFR values and distribution volume, linear and quadratic regressions were tested for GFR = f (V) and GFR = f (In (V). The lowest observed standard deviation (3,6 mL/min; n = 82) was for GFR 234 = f (V 4h ) using a quadratic equation. This was applied to the second patient group for GFR estimation with 4 hours single point plasma method. Estimations were compared to GFR plasma values. For comparison, GFR estimations were also obtained using the Christensen's equation. (authors)

  18. A study of nasal cavity volume by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tosa, Yasuyoshi [Showa Univ., Tokyo (Japan). School of Medicine

    1992-04-01

    The nasal cavity volume in 69 healthy volunteers from 8 to 23 years old (17 males and 52 females) was studied using magnetic resonance imaging (MRI). Merits of MRI such as no radiation exposure, less artifact due to bone and air and measurement of intravascular blood flow; and demerits such as contraindication in users of heart pace-makers or magnetic clips, contraindication in people with claustrophobia and influence of environmental magnetic fields must be considered. A Magunetom M10 (Siemens), a superconduction device with 1.0 Tesla magnetic flux density was used. Enhanced patterns of T[sub 1], and pulse lines were photographed at 600 msec TR (repetition time) and 19 msec TE (echo time) using SE (spin echo) and short SE (spin echo), and 3 or 4 mm slices. Photographs were made of the piriform aperture, choana, superior-middle-inferior concha including the nasal meatus, the frontal sinus, maxillary sinus, cribriform plate, and upper surface of the palate. The line connecting the maximum depression point in the nasal root and the pontomedullary junction was selected by sagittal median section, because this corresponds well with the CM (canthomeatal) line which is useful in CT (computed tomography). The transverse section of the nasal cavity volume was traced by display console with an accessory MRI device and calculated by integration of the slice width. The increase of height and body weight neared a plateau at almost 16 years, whereas increase of nasal cavity volume continued until about 20 years. Pearson's coefficient of correlation and regression line were significant. There were no significant differences in these parameters between male and female groups. Comparatively strong correlation between nasal cavity volume, and age, height and body weight was statistically evident. (author).

  19. Impact of institutional volume and experience with CT interpretation on sizing of transcatheter aortic valves: A multicenter retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Divya Ratan [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Division of Interventional Cardiology, Banner University Medical Center, Phoenix, AZ (United States); Pershad, Yash [Department of Radiology, Banner University Medical Center, Phoenix, AZ (United States); Pershad, Ashish [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Division of Interventional Cardiology, Banner University Medical Center, Phoenix, AZ (United States); Fang, Kenith [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Division of Cardiothoracic Surgery, Banner University Medical Center, Phoenix, AZ (United States); Gellert, George [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Department of Anesthesiology, Banner University Medical Center, Phoenix, AZ (United States); Morris, Michael F., E-mail: mfmorris@mail.arizona.edu [Cardiovascular Institute, Banner University Medical Center, Phoenix, AZ (United States); Department of Radiology, Banner University Medical Center, Phoenix, AZ (United States)

    2016-12-15

    Background: Computed tomography (CT) has become the standard imaging modality for pre-procedural aortic annular sizing prior to transcatheter aortic valve replacement (TAVR). We hypothesized that the accuracy of CT derived annular measurements would be greater at sites with higher TAVR procedural volume. Methods: Within a large integrated health system, TAVR was performed at low (<40 cases), intermediate (40–75 cases), and high-volume sites (>75 cases). 181 patients underwent TAVR with a Sapien XT transcatheter heart valve (THV). Two blinded experienced readers independently remeasured the annulus on CT and compared their measurements to site reported measurements. Hypothetical THV sizes were chosen based on measurements from site CT reports and independent readers’ measurements, and compared to the implanted THV size. Results: Correlation between site reported measurements and independent readers measurements of mean annulus size varied between low-volume (r = 0.31, p = 0.18), intermediate-volume (r = 0.34, p = 0.01), and high-volume sites (r = 0.96, p < 0.01). On multivariate analysis, interpretation of ≥20 CT scans (OR 0.29; 95% CI 0.03–0.81; p 0.02) and high-volume site (OR 0.16; 95% CI 0.10–0.82; p 0.02) were associated with reduced mismatch between the site predicted THV size and independent readers predicted THV size. Mismatch between site predicted THV size and implanted THV size was associated with a worse 30-day composite of mortality, dialysis-dependent renal failure, cerebrovascular accident, new permanent pacemaker, and hospital readmission (55.3 vs. 38.7%; p = 0.05). Conclusions: Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. These findings should be confirmed in larger, prospective studies. - Highlights: • Accuracy of CT aortic annular sizing is improved with higher individual experience and site TAVR volume. • CT readers with experience interpreting ≥20 pre-TAVR CT scans had

  20. Quantificação em escala de bancada do volume de ar em ligações prediais de água Measuring air volume in household pipes by means of a pilot scale study

    Directory of Open Access Journals (Sweden)

    Ney Procópio Lopes

    2011-12-01

    Full Text Available A presente pesquisa em escala piloto, simulando trecho de uma rede interligada a um ramal predial, visou quantificar o volume de ar aferido pelos hidrômetros residenciais. Para tal fim, testaram-se ventosas, bloqueadores de ar e válvulas eliminadoras de ar. Sob condições normais de operação da rede, o volume de ar medido pelos hidrômetros é comparável ao encontrado na água natural, não justificando a instalação de equipamento de eliminação de ar de qualquer natureza. Todavia, logo após esvaziamento da rede interligada ao ramal, a sobremedição pode atingir até 21% em condições de pressão máxima na rede de distribuição (500 kPa. Por fim, verificou-se que a menor vazão afluente associa-se ao maior volume de ar aferido pelo hidrômetro. Dessa forma, é possível supor que os consumidores situados na menor faixa de consumo sejam os mais prejudicados pela situação de desabastecimento.The purpose of the present work is to evaluate the volume of air measured in domestic water supply pipe connections. Tests were performed to evaluate the efficiency and applicability of air reducing valves in domestic water supply connections. The results obtained under regular water supply conditions showed that the volume of air in the water measured by the hydrometers is comparable to the one found in natural waters. On the other hand, other tests, right after emptying the network connected to the domestic water supply pipe, revealed that the volume of water which gets to the gauged reservoir comprehends up to 21% of the total air-water volume recorded by the hydrometer for the experiments performed under pressure of 500 kPa.

  1. Report on the behalf of the special commission for the examination of the bill project, after activation of the accelerated procedure, related to energy transition for a green growth (nr 2188) - Nr 2230. Volume I, Volume II - comparative table, Volume III - hearings, impact study

    International Nuclear Information System (INIS)

    Bareigts, Ericka; Battistel, Marie-Noelle; Buis, Sabine; Baupin, Denis; Plisson, Philippe

    2014-01-01

    The first volume of this huge report reports the general discussion and the detailed examination, discussion and modifications of the French bill project on energy transition. The addressed topics are: the definition of common objectives for a successful energy transition, for a strengthening of France energy independence and for the struggle against global warming; a better renovation of buildings to save energy, to reduce prices and to create jobs; the development of clean transports to improve air quality and to protect health; the struggle against wastage and the promotion of circular economy from product design to product recycling; the promotion of renewable energies to diversify our energies and valorise territorial resources; the strengthening of nuclear safety and citizen information; the simplification and clarification of procedures for efficiency and competitiveness gains; the empowerment of citizen, enterprises, territories and State to act together. The second volume proposes a table which gives a comparative overview between the bill project text and the text modified and adopted by the commission. The third volume reports hearings of the minister and of several representatives of professional, public, and consumer organisations and bodies. It also contains the report of an impact study performed on all the different arrangements and measures contained by the bill project

  2. Different partial volume correction methods lead to different conclusions

    DEFF Research Database (Denmark)

    Greve, Douglas N; Salat, David H; Bowen, Spencer L

    2016-01-01

    A cross-sectional group study of the effects of aging on brain metabolism as measured with (18)F-FDG-PET was performed using several different partial volume correction (PVC) methods: no correction (NoPVC), Meltzer (MZ), Müller-Gärtner (MG), and the symmetric geometric transfer matrix (SGTM) usin...

  3. Brookhaven National Laboratory 2008 Site Environment Report Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Brookhaven National Laboratory

    2009-10-01

    Brookhaven National Laboratory (BNL) prepares an annual Site Environmental Report (SER) in accordance with DOE Order 231.1A, Environment, Safety and Health Reporting of the U.S. Department of Energy. The report is written to inform the public, regulators, employees, and other stakeholders of the Laboratory's environmental performance during the calendar year in review. Volume I of the SER summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and performance in restoration and surveillance monitoring programs. BNL has prepared annual SERs since 1971 and has documented nearly all of its environmental history since the Laboratory's inception in 1947. Volume II of the SER, the Groundwater Status Report, also is prepared annually to report on the status of and evaluate the performance of groundwater treatment systems at the Laboratory. Volume II includes detailed technical summaries of groundwater data and its interpretation, and is intended for internal BNL users, regulators, and other technically oriented stakeholders. A brief summary of the information contained in Volume II is included in this volume in Chapter 7, Groundwater Protection. Both reports are available in print and as downloadable files on the BNL web page at http://www.bnl.gov/ewms/ser/. An electronic version on compact disc is distributed with each printed report. In addition, a summary of Volume I is prepared each year to provide a general overview of the report, and is distributed with a compact disc containing the full report.

  4. Study on magnetic field mapping within cylindrical center volume of general magnet

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Li; Lee, Sang Jin [Uiduk University, Gyeongju (Korea, Republic of)

    2016-06-15

    For the magnetic field analysis or design, it is important to know the behavior of the magnetic field in an interesting space. Magnetic field mapping becomes a useful tool for the study of magnetic field. In this paper, a numerical way for mapping the magnetic field within the cylindrical center volume of magnet is presented, based on the solution of the Laplace's equation in the cylindrical coordinate system. The expression of the magnetic field can be obtained by the magnetic flux density, which measured in the mapped volume. According to the form of the expression, the measurement points are arranged with the parallel cylindrical line (PCL) method. As example, the magnetic flux density generated by an electron cyclotron resonance ion source (ECRIS) magnet and a quadrupole magnet were mapped using the PCL method, respectively. The mapping results show the PCL arrangement method is feasible and convenience to map the magnetic field within a cylindrical center volume generated by the general magnet.

  5. Volume-dependent hemodynamic effects of blood collection in canine donors - evaluation of 13% and 15% of total blood volume depletion

    Directory of Open Access Journals (Sweden)

    RUI R.F. FERREIRA

    2015-03-01

    Full Text Available Background: There is no consensus regarding the blood volume that could be safely donated by dogs, ranging from 11 to 25% of its total blood volume (TBV. No previous studies evaluated sedated donors.Aim: To evaluate the hemodynamic effects of blood collection from sedated and non-sedated dogs and to understand if such effects were volume-dependent.Materials and Methods: Fifty three donations of 13% of TBV and 20 donations of 15% TBV were performed in dogs sedated with diazepam and ketamine. Additionally, a total of 30 collections of 13% TBV and 20 collections of 15% TBV were performed in non-sedated dogs. Non-invasive arterial blood pressures and pulse rates were registered before and 15 min after donation. Results: Post-donation pulse rates increased significantly in both sedated groups, with higher differences in the 15% TBV collections. Systolic arterial pressures decreased significantly in these groups, while diastolic pressures increased significantly in 13% TBV donations. Non-sedated groups revealed a slight, but significant, SBP decrease. No clinical signs related to donations were registered.Conclusion: These results suggest that the collection of 15% TBV in sedated donors induces hemodynamic variations that may compromise the harmlessness of the procedure, while it seems to be a safe procedure in non-sedated dogs.

  6. Inner volume leakage during integrated leakage rate testing

    International Nuclear Information System (INIS)

    Glover, J.P.

    1987-01-01

    During an integrated leak rate test (ILRT), the containment structure is maintained at test pressure with most penetrations isolated. Since penetrations typically employ dual isolation, the possibility exists for the inner isolation to leak while the outer holds. In this case, the ILRT instrumentation system would indicate containment out-leakage when, in fact, only the inner volume between closures is being pressurized. The problem is compounded because this false leakage is not readily observable outside of containment by standard leak inspection techniques. The inner volume leakage eventually subsides after the affected volumes reach test pressure. Depending on the magnitude of leakage and the size of the volumes, equalization could occur prior to the end of the pretest stabilization period, or significant false leakages may persist throughout the entire test. Two simple analyses were performed to quantify the effects of inside volume leakages. First, a lower bound for the equalization time was found. A second analysis was performed to find an approximate upper bound for the stabilization time. The results of both analyses are shown

  7. Volume conduction effects on wavelet cross-bicoherence analysis

    International Nuclear Information System (INIS)

    Memon, I.A.; Channa, C.

    2013-01-01

    Cross-bicoherence analysis is one of the important nonlinear signal processing tools which is used to measure quadratic phase coupling between frequencies of two different time series. It is frequently used in the diagnosis of various cognitive and neurological disorders in EEG (Electroencephalography) analysis. Volume conduction effects of various uncorrelated sources present in the brain can produce biased estimates into the estimated values of cross-bicoherence function. Previous studies have discussed volume conduction effects on coherence function which is used to measure linear relationship between EEG signals in terms of their phase and amplitude. However, volume conduction effect on cross-bicoherence analysis which is quite a different technique has not been investigated up to now to the best of our knowledge. This study is divided into two major parts, the first part deals with the investigation of VCUS (Volume Conduction effects due to Uncorrelated Sources) characteristics on EEG-cross-bicoherence analysis. The simulated EEG data due to uncorrelated sources present in the brain was used in this part of study. The next part of study is based upon investigating the effects of VCUS on the statistical analysis of results of EEG-based cross-bicoherence analysis. The study provides an important clinical application because most of studies based on EEG cross-bicoherence analysis have avoided the issue of VCUS. The cross-bicoherence analysis was performed by detecting the change in MSCB (Magnitude Square Cross-Bicoherence Function) between EEG activities of change detection and no-change detection trials. The real EEG signals were used. (author)

  8. Effect of restoration volume on stresses in a mandibular molar: a finite element study.

    Science.gov (United States)

    Wayne, Jennifer S; Chande, Ruchi; Porter, H Christian; Janus, Charles

    2014-10-01

    There can be significant disagreement among dentists when planning treatment for a tooth with a failing medium-to-large--sized restoration. The clinician must determine whether the restoration should be replaced or treated with a crown, which covers and protects the remaining weakened tooth structure during function. The purpose of this study was to evaluate the stresses generated in different sized amalgam restorations via a computational modeling approach and reveal whether a predictable pattern emerges. A computer tomography scan was performed of an extracted mandibular first molar, and the resulting images were imported into a medical imaging software package for tissue segmentation. The software was used to separate the enamel, dentin, and pulp cavity through density thresholding and surface rendering. These tissue structures then were imported into 3-dimensional computer-aided design software in which material properties appropriate to the tissues in the model were assigned. A static finite element analysis was conducted to investigate the stresses that result from normal occlusal forces. Five models were analyzed, 1 with no restoration and 4 with increasingly larger restoration volume proportions: a normal-sized tooth, a small-sized restoration, 2 medium-sized restorations, and 1 large restoration as determined from bitewing radiographs and occlusal surface digital photographs. The resulting von Mises stresses for dentin-enamel of the loaded portion of the tooth grew progressively greater as the size of the restoration increased. The average stress in the normal, unrestored tooth was 4.13 MPa, whereas the smallest restoration size increased this stress to 5.52 MPa. The largest restoration had a dentin-enamel stress of 6.47 MPa. A linear correlation existed between restoration size and dentin-enamel stress, with an R(2) of 0.97. A larger restoration volume proportion resulted in higher dentin-enamel stresses under static loading. A comparison of the von Mises

  9. Novel genetic loci associated with hippocampal volume

    OpenAIRE

    Hibar, Derrek P.; Adams, Hieab H. H.; Jahanshad, Neda; Chauhan, Ganesh; Stein, Jason L.; Hofer, Edith; Renteria, Miguel E.; Bis, Joshua C.; Arias-Vasquez, Alejandro; Ikram, M. Kamran; Desrivieres, Sylvane; Vernooij, Meike W.; Abramovic, Lucija; Alhusaini, Saud; Amin, Najaf

    2017-01-01

    International audience; The hippocampal formation is a brain structure integrally involved in episodic memory, spatial navigation, cognition and stress responsiveness. Structural abnormalities in hippocampal volume and shape are found in several common neuropsychiatric disorders. To identify the genetic underpinnings of hippocampal structure here we perform a genome-wide association study (GWAS) of 33,536 individuals and discover six independent loci significantly associated with hippocampal ...

  10. High-Performance Home Technologies: Solar Thermal & Photovoltaic Systems; Volume 6 Building America Best Practices Series

    Energy Technology Data Exchange (ETDEWEB)

    None

    2007-06-01

    The sixth volume of the Building America Best Practices Series presents information that is useful throughout the U.S. for enhancing the energy efficiency practices in the specific climate zones that are presented in each of the volumes.

  11. Changes of pituitary gland volume in Kennedy disease.

    Science.gov (United States)

    Pieper, C C; Teismann, I K; Konrad, C; Heindel, W L; Schiffbauer, H

    2013-12-01

    Kennedy disease is a rare X-linked neurodegenerative disorder caused by a CAG repeat expansion in the first exon of the androgen-receptor gene. Apart from neurologic signs, this mutation can cause a partial androgen insensitivity syndrome with typical alterations of gonadotropic hormones produced by the pituitary gland. The aim of the present study was therefore to evaluate the impact of Kennedy disease on pituitary gland volume under the hypothesis that endocrinologic changes caused by partial androgen insensitivity may lead to morphologic changes (ie, hypertrophy) of the pituitary gland. Pituitary gland volume was measured in sagittal sections of 3D T1-weighted 3T-MR imaging data of 8 patients with genetically proven Kennedy disease and compared with 16 healthy age-matched control subjects by use of Multitracer by a blinded, experienced radiologist. The results were analyzed by a univariant ANOVA with total brain volume as a covariant. Furthermore, correlation and linear regression analyses were performed for pituitary volume, patient age, disease duration, and CAG repeat expansion length. Intraobserver reliability was evaluated by means of the Pearson correlation coefficient. Pituitary volume was significantly larger in patients with Kennedy disease (636 [±90] mm(3)) than in healthy control subjects (534 [±91] mm(3)) (P = .041). There was no significant difference in total brain volume (P = .379). Control subjects showed a significant decrease in volume with age (r = -0.712, P = .002), whereas there was a trend to increasing gland volume in patients with Kennedy disease (r = 0.443, P = .272). Gland volume correlated with CAG repeat expansion length in patients (r = 0.630, P = .047). The correlation coefficient for intraobserver reliability was 0.94 (P pituitary volume that correlated with the CAG repeat expansion length. This could reflect hypertrophy as the result of elevated gonadotropic hormone secretion caused by the androgen receptor mutation with partial

  12. Regional Differences in Brain Volume Predict the Acquisition of Skill in a Complex Real-Time Strategy Videogame

    Science.gov (United States)

    Basak, Chandramallika; Voss, Michelle W.; Erickson, Kirk I.; Boot, Walter R.; Kramer, Arthur F.

    2011-01-01

    Previous studies have found that differences in brain volume among older adults predict performance in laboratory tasks of executive control, memory, and motor learning. In the present study we asked whether regional differences in brain volume as assessed by the application of a voxel-based morphometry technique on high resolution MRI would also…

  13. Cerebrospinal fluid volume measurements in hydrocephalic rats.

    Science.gov (United States)

    Basati, Sukhraaj; Desai, Bhargav; Alaraj, Ali; Charbel, Fady; Linninger, Andreas

    2012-10-01

    Object Experimental data about the evolution of intracranial volume and pressure in cases of hydrocephalus are limited due to the lack of available monitoring techniques. In this study, the authors validate intracranial CSF volume measurements within the lateral ventricle, while simultaneously using impedance sensors and pressure transducers in hydrocephalic animals. Methods A volume sensor was fabricated and connected to a catheter that was used as a shunt to withdraw CSF. In vitro bench-top calibration experiments were created to provide data for the animal experiments and to validate the sensors. To validate the measurement technique in a physiological system, hydrocephalus was induced in weanling rats by kaolin injection into the cisterna magna. At 28 days after induction, the sensor was implanted into the lateral ventricles. After sealing the skull using dental cement, an acute CSF drainage/infusion protocol consisting of 4 sequential phases was performed with a pump. Implant location was confirmed via radiography using intraventricular iohexol contrast administration. Results Controlled CSF shunting in vivo with hydrocephalic rats resulted in precise and accurate sensor measurements (r = 0.98). Shunting resulted in a 17.3% maximum measurement error between measured volume and actual volume as assessed by a Bland-Altman plot. A secondary outcome confirmed that both ventricular volume and intracranial pressure decreased during CSF shunting and increased during infusion. Ventricular enlargement consistent with successful hydrocephalus induction was confirmed using imaging, as well as postmortem. These results indicate that volume monitoring is feasible for clinical cases of hydrocephalus. Conclusions This work marks a departure from traditional shunting systems currently used to treat hydrocephalus. The overall clinical application is to provide alternative monitoring and treatment options for patients. Future work includes development and testing of a chronic

  14. Correlated volume-energy fluctuations of phospholipid membranes: A simulation study

    DEFF Research Database (Denmark)

    Pedersen, Ulf. R.; Peters, Günther H.J.; Schröder, Thomas B.

    2010-01-01

    This paper reports all-atom computer simulations of five phospholipid membranes (DMPC, DPPC, DMPG, DMPS, and DMPSH) with focus on the thermal equilibrium fluctuations of volume, energy, area, thickness, and chain order. At constant temperature and pressure, volume and energy exhibit strong...... membranes, showing a similar picture. The cause of the observed strong correlations is identified by splitting volume and energy into contributions from tails, heads, and water, and showing that the slow volume−energy fluctuations derive from van der Waals interactions of the tail region; they are thus...

  15. Effect of fluid loading on left ventricular volume and stroke volume variability in patients with end-stage renal disease: a pilot study

    Science.gov (United States)

    Kanda, Hirotsugu; Hirasaki, Yuji; Iida, Takafumi; Kanao-Kanda, Megumi; Toyama, Yuki; Kunisawa, Takayuki; Iwasaki, Hiroshi

    2015-01-01

    Purpose The aim of this study was to investigate fluid loading-induced changes in left ventricular end-diastolic volume (LVEDV) and stroke volume variability (SVV) in patients with end-stage renal disease (ESRD) using real-time three-dimensional transesophageal echocardiography and the Vigileo-FloTrac system. Patients and methods After obtaining ethics committee approval and informed consent, 28 patients undergoing peripheral vascular procedures were studied. Fourteen patients with ESRD on hemodialysis (HD) were assigned to the HD group and 14 patients without ESRD were assigned to the control group. Institutional standardized general anesthesia was provided in both groups. SVV was measured using the Vigileo-FloTrac system. Simultaneously, a full-volume three-dimensional transesophageal echocardiography dataset was acquired to measure LVEDV, left ventricular end-systolic volume, and left ventricular ejection fraction. Measurements were obtained before and after loading 500 mL hydroxyethyl starch over 30 minutes in both groups. Results In the control group, intravenous colloid infusion was associated with a significant decrease in SVV (13.8%±2.6% to 6.5%±2.6%, P<0.001) and a significant increase in LVEDV (83.6±23.4 mL to 96.1±28.8 mL, P<0.001). While SVV significantly decreased after infusion in the HD group (16.2%±6.0% to 6.2%±2.8%, P<0.001), there was no significant change in LVEDV. Conclusion Our preliminary data suggest that fluid responsiveness can be assessed not by LVEDV but also by SVV due to underlying cardiovascular pathophysiology in patients with ESRD. PMID:26527879

  16. Associations between regional brain volumes at term-equivalent age and development at 2 years of age in preterm children.

    Science.gov (United States)

    Lind, Annika; Parkkola, Riitta; Lehtonen, Liisa; Munck, Petriina; Maunu, Jonna; Lapinleimu, Helena; Haataja, Leena

    2011-08-01

    Altered brain volumes and associations between volumes and developmental outcomes have been reported in prematurely born children. To assess which regional brain volumes are different in very low birth weight (VLBW) children without neurodevelopmental impairments ([NDI] cerebral palsy, hearing loss, blindness and significantly delayed cognitive performance) compared with VLBW children with NDI, and to evaluate the association between regional brain volumes at term-equivalent age and cognitive development and neurological performance at a corrected age of 2 years. The study group consisted of a regional cohort of 164 VLBW children, divided into one group of children without NDI (n = 148) and one group of children with NDI (n = 16). Brain (MRI) was performed at term-equivalent age, from which brain volumes were manually analysed. Cognitive development was assessed with the Bayley Scales of Infant Development II (BSID-II), and neurological performance with the Hammersmith Infant Neurological Examination at the corrected age of 2 years. The volumes of total brain tissue, cerebrum, frontal lobes, basal ganglia and thalami, and cerebellum were significantly smaller, and the volume of the ventricles significantly larger, in the children with NDI than in those without NDI. Even in children without NDI, a smaller cerebellar volume was significantly correlated with poor neurological performance at 2 years of corrected age. Volumetric analysis at brain MRI can provide an additional parameter for early prediction of outcome in VLBW children.

  17. Topologically-based visualization of large-scale volume data

    International Nuclear Information System (INIS)

    Takeshima, Y.; Tokunaga, M.; Fujishiro, I.; Takahashi, S.

    2004-01-01

    Due to the recent progress in the performance of computing/measurement environments and the advent of ITBL environments, volume datasets have become larger and more complicated. Although computer visualization is one of the tools to analyze such datasets effectively, it is almost impossible to adjust the visualization parameter value by trial and error without taking the feature of a given volume dataset into consideration. In this article, we introduce a scheme of topologically-based volume visualization, which is intended to choose appropriate visualization parameter values automatically through topological volume skeletonization. (author)

  18. Microstructure-Aided Digital Volume Correlation

    Directory of Open Access Journals (Sweden)

    Hild F.

    2010-06-01

    Full Text Available This paper describes how volumic images of a composite material could be used to measure 3D displacement fields, and assess mechanical properties. The exemple of a tensile test performed on a sample made of an energetic material is chosen. Different tools are used, namely, X-ray microtomography of an in situ experiment, image acquisition and processing, volume correlation to measure 3D displacement fields. The principle of an integrated approach is finally introduced.

  19. Enhancing economic competiveness of dish Stirling technology through production volume and localization: Case study for Morocco

    Science.gov (United States)

    Larchet, Kevin; Guédez, Rafael; Topel, Monika; Gustavsson, Lars; Machirant, Andrew; Hedlund, Maria-Lina; Laumert, Björn

    2017-06-01

    The present study quantifies the reduction in the levelized cost of electricity (LCoE) and capital expenditure (CAPEX) of a dish Stirling power plant (DSPP) through an increase in localization and unit production volume. Furthermore, the localization value of the plant is examined to determine how much investment is brought into the local economy. Ouarzazate, Morocco, was chosen as the location of the study due to the country's favorable regulatory framework with regards to solar power technologies and its established industry in the concentrating solar power (CSP) field. A detailed techno-economic model of a DSPP was developed using KTH's in-house modelling tool DYESOPT, which allows power plant evaluation by means of technical and economic performance indicators. Results on the basis of LCoE and CAPEX were compared between two different cases of production volume, examining both a minimum and maximum level of localization. Thereafter, the DSPP LCoE and localization value were compared against competing solar technologies to evaluate its competitiveness. In addition, a sensitivity analysis was conducted around key design parameters. The study confirms that the LCoE of a DSPP can be reduced to values similar to solar photovoltaic (PV) and lower than other CSP technologies. Furthermore, the investment in the local economy is far greater when compared to PV and of the same magnitude to other CSP technologies. The competiveness of a DSPP has the potential to increase further when coupled with thermal energy storage (TES), which is currently under development.

  20. Influence of thyroid volume reduction on absorbed dose in "1"3"1I therapy studied by using Geant4 Monte Carlo simulation

    International Nuclear Information System (INIS)

    Rahman, Ziaur; Arshed, Waheed; Ahmed, Waheed; Mirza, Sikander M.; Mirza, Nasir M.

    2014-01-01

    A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of "1"3"1I with volume/mass of thyroid, for water, ICRP- and ICRU-soft tissue taken as thyroid material. A Monte Carlo model of the thyroid, in the Geant4 radiation transport simulation toolkit was constructed to compute the β- and γ-absorbed dose in the simulated thyroid phantom for various values of its volume. The effect of the size and shape of the thyroid on energy deposition per decay has also been studied by using spherical, ellipsoidal and cylindrical models for the thyroid and varying its volume in 1-25 cm"3 range. The relative differences of Geant4 results for different models with each other and MCNP results lie well below 1.870%. The maximum relative difference among the Geant4 estimated results for water with ICRP and ICRU soft tissues is not more than 0.225%. S-values for ellipsoidal, spherical and cylindrical thyroid models were estimated and the relative difference with published results lies within 3.095%. The absorbed fraction values for beta particles show a good agreement with published values within 2.105% deviation. The Geant4 based simulation results of absorbed fractions for gammas again show a good agreement with the corresponding MCNP and EGS4 results (± 6.667%) but have 29.032% higher values than that of MIRD calculated values. Consistent with previous studies, the reduction of the thyroid volume is found to have a substantial effect on the absorbed dose. Geant4 simulations confirm dose dependence on the volume/mass of thyroid in agreement with MCNP and EGS4 computed values but are substantially different from MIRD8 data. Therefore, inclusion of size/mass dependence is indicated for "1"3"1I radiotherapy of the thyroid. (authors)

  1. Which echocardiographic parameter is a better marker of volume status in hemodialysis patients?

    Science.gov (United States)

    Sabaghian, Tahereh; Hajibaratali, Bahareh; Samavat, Shiva

    2016-11-01

    Bio-impedance analysis (BIA) is a preferred method for estimating the volume status. However, it cannot be utilized in daily practice. Since the assessment of the volume status is important and challenging for hemodialysis (HD) patients, the aim of study was to determine the volume status in chronic HD patients using echocardiographic parameters and assess its correlation with BIA. In this cross-sectional analysis, echocardiography and BIA were performed on 30 chronic HD patients 30 min before and 30 min after dialysis. All the cases of dialysis were performed in the middle of the week. This study also assessed the correlation between echocardiographic parameters and BIA parameters. There were significant differences between ECW, TBW, and TBW% (TBW/W) before and after HD. Significant differences were observed between echocardiographic parameters of IVCD, IVCDi min , IVCDi max before and after the HD. LVEDD, LVESD, LA area, mitral valve inflow, E/E', and IVRT, were improved after dialysis, too. There was a significant correlation between IVCDi min as an index of volume status, ECW% and TBW% before HD and IVCDi min change after dialysis had a significant correlation with %ECW change after dialysis. Comparison between hypertensive and non-hypertensive groups indicated IVCDi min was significantly lower in non-hypertensive group after dialysis. Our results showed a correlation between IVCDi min and BIA parameters before HD. So, it seems that IVCDi min can be a good parameter for determining the volume status of HD patients. However, further studies, with larger sample size and with a prospective study design, are required to confirm these results.

  2. Occipital Lobe Gray Matter Volume in Male Patients with Chronic Schizophrenia: A Quantitative MRI Study

    Science.gov (United States)

    Onitsuka, Toshiaki; McCarley, Robert W.; Kuroki, Noriomi; Dickey, Chandlee C.; Kubicki, Marek; Demeo, Susan S.; Frumin, Melissa; Kikinis, Ron; Jolesz, Ferenc A.; Shenton, Martha E.

    2008-01-01

    Schizophrenia is characterized by deficits in cognition as well as visual perception. There have, however, been few magnetic resonance imaging (MRI) studies of the occipital lobe as an anatomically defined region of interest in schizophrenia. To examine whether or not patients with chronic schizophrenia show occipital lobe volume abnormalities, we measured gray matter volumes for both the primary visual area (PVA) and the visual association areas (VAA) using MRI based neuroanatomical landmarks and three-dimensional information. PVA and VAA gray matter volumes were measured using high-spatial resolution MRI in 25 male patients diagnosed with chronic schizophrenia and in 28 male normal controls. Chronic schizophrenia patients showed reduced bilateral VAA gray matter volume (11%), compared with normal controls, whereas patients showed no group difference in PVA gray matter volume. These results suggest that reduced bilateral VAA may be a neurobiological substrate of some of the deficits observed in early visual processing in schizophrenia. PMID:17350226

  3. Mapping growing stock volume and forest live biomass: a case study of the Polissya region of Ukraine

    Science.gov (United States)

    Bilous, Andrii; Myroniuk, Viktor; Holiaka, Dmytrii; Bilous, Svitlana; See, Linda; Schepaschenko, Dmitry

    2017-10-01

    Forest inventory and biomass mapping are important tasks that require inputs from multiple data sources. In this paper we implement two methods for the Ukrainian region of Polissya: random forest (RF) for tree species prediction and k-nearest neighbors (k-NN) for growing stock volume and biomass mapping. We examined the suitability of the five-band RapidEye satellite image to predict the distribution of six tree species. The accuracy of RF is quite high: ~99% for forest/non-forest mask and 89% for tree species prediction. Our results demonstrate that inclusion of elevation as a predictor variable in the RF model improved the performance of tree species classification. We evaluated different distance metrics for the k-NN method, including Euclidean or Mahalanobis distance, most similar neighbor (MSN), gradient nearest neighbor, and independent component analysis. The MSN with the four nearest neighbors (k = 4) is the most precise (according to the root-mean-square deviation) for predicting forest attributes across the study area. The k-NN method allowed us to estimate growing stock volume with an accuracy of 3 m3 ha-1 and for live biomass of about 2 t ha-1 over the study area.

  4. Limiting volume with modern ventilators.

    Science.gov (United States)

    Wing, Thomas J; Haan, Lutana; Ashworth, Lonny J; Anderson, Jeff

    2015-06-01

    The acute respiratory distress syndrome (ARDS) network low tidal-volume study comparing tidal volumes of 12 ml/kg versus 6 ml/kg was published in 2000. The study was stopped early as data revealed a 22% relative reduction in mortality rate when using 6 ml/kg tidal volume. The current generation of critical care ventilators allows the tidal volume to be set during volume-targeted, assist/control (volume A/C); however, some ventilators include options that may prevent the tidal volume from being controlled. The purpose of this bench study was to evaluate the delivered tidal volume, when these options are active, in a spontaneously breathing lung model using an electronic breathing simulator. Four ventilators were evaluated: CareFusion AVEA (AVEA), Dräger Evita® XL (Evita XL), Covidien Puritan Bennett® 840(TM) (PB 840), and Maquet SERVO-i (SERVO-i). Each ventilator was connected to the Hans Rudolph Electronic Breathing Simulator at an amplitude of 0 cm H2O and then 10 cm H2O. All four ventilators were set to deliver volume A/C, tidal volume 400 ml, respiratory rate 20 bpm, positive end-expiratory pressure 5 cm H2O, peak flowrate 60 L/min. The displayed tidal volume was recorded for each ventilator at the above settings with additional options OFF and then ON. The AVEA has two options in volume A/C: demand breaths and V-sync. When activated, these options allow the patient to exceed the set tidal volume. When using the Evita XL, the option AutoFlow can be turned ON or OFF, and when this option is ON, the tidal volume may vary. The PB 840 does not have any additional options that affect volume delivery, and it maintains the set tidal volume regardless of patient effort. The SERVO-i's demand valve allows additional flow if the patient's inspiratory flowrate exceeds the set flowrate, increasing the delivered tidal volume; this option can be turned OFF with the latest software upgrade. Modern ventilators have an increasing number of optional settings. These settings may

  5. Method and apparatus for imaging volume data

    International Nuclear Information System (INIS)

    Drebin, R.; Carpenter, L.C.

    1987-01-01

    An imaging system projects a two dimensional representation of three dimensional volumes where surface boundaries and objects internal to the volumes are readily shown, and hidden surfaces and the surface boundaries themselves are accurately rendered by determining volume elements or voxels. An image volume representing a volume object or data structure is written into memory. A color and opacity is assigned to each voxel within the volume and stored as a red (R), green (G), blue (B), and opacity (A) component, three dimensional data volume. The RGBA assignment for each voxel is determined based on the percentage component composition of the materials represented in the volume, and thus, the percentage of color and transparency associated with those materials. The voxels in the RGBA volume are used as mathematical filters such that each successive voxel filter is overlayed over a prior background voxel filter. Through a linear interpolation, a new background filter is determined and generated. The interpolation is successively performed for all voxels up to the front most voxel for the plane of view. The method is repeated until all display voxels are determined for the plane of view. (author)

  6. Effect of hydration status on atrial and ventricular volumes and function in healthy adult volunteers.

    Science.gov (United States)

    Schantz, Daryl I; Dragulescu, Andreea; Memauri, Brett; Grotenhuis, Heynric B; Seed, Mike; Grosse-Wortmann, Lars

    2016-10-01

    Assessment of cardiac chamber volumes is a fundamental part of cardiac magnetic resonance (CMR) imaging. While the effects of inter- and intraobserver variability have been studied and have a recognized effect on the comparability of serial cardiac MR imaging studies, the effect of differences in hydration status has not been evaluated. To evaluate the effects of volume administration on cardiac chamber volumes. Thirteen healthy adults underwent a baseline cardiac MR to evaluate cardiac chamber volumes after an overnight fast. They were then given two saline boluses of 10 ml/kg of body weight and the cardiac MR was repeated immediately after each bolus. From the baseline scan to the final scan there was a significant increase in all four cardiac chamber end-diastolic volumes. Right atrial volumes increased 8.0%, from 61.1 to 66.0 ml/m2 (PHydration status has a significant effect on the end-diastolic volumes of all cardiac chambers assessed by cardiac MR. Thus, hydration represents a "variable" that should be taken into account when assessing cardiac chamber volumes, especially when performing serial imaging studies in a patient.

  7. Comparative Studies on Thermal Performance of Conic Cut Twist Tape Inserts with SiO2 and TiO2 Nanofluids

    Directory of Open Access Journals (Sweden)

    Sami D. Salman

    2015-01-01

    Full Text Available This paper presents a comparison study on thermal performance conic cut twist tape inserts in laminar flow of nanofluids through a constant heat fluxed tube. Three tape configurations, namely, quadrant cut twisted tape (QCT, parabolic half cut twisted tape (PCT, and triangular cut twisted (VCT of twist ratio y = 2.93 and cut depth de = 0.5 cm were used with 1% and 2% volume concentration of SiO2/water and TiO2/water nanofluids. Typical twist tape with twist ratio of y = 2.93 was used for comparison. The results show that the heat transfer was enhanced by increasing of Reynolds number and nanoparticles concentration of nanofluid. The results have also revealed that the use of twist tape enhanced the heat transfer coefficient significantly and maximum heat transfer enhancement was achieved by the presence of triangular cut twist tape insert with 2% volume concentration of SiO2 nanofluid. Over the range investigated, the maximum thermal performance factor of 5.13 is found with the simultaneous use of the SiO2 nanofluid at 2% volume concentration VCT at Reynolds number of 220. Furthermore, new empirical correlations for Nusselt number, friction factor, and thermal performance factor are developed and reported.

  8. Estimation of lung volume and pulmonary blood volume from radioisotopic images

    International Nuclear Information System (INIS)

    Kanazawa, Minoru

    1989-01-01

    Lung volume and pulmonary blood volume in man were estimated from the radioisotopic image using single photon emission computed tomography (SPECT). Six healthy volunteers were studied in a supine position with normal and altered lung volumes by applying continuous negative body-surface pressure (CNP) and by positive end-expiratory pressure (PEEP). 99m Tc labeled human serum albumin was administered as an aerosol to image the lungs. The CNP caused the diaphragm to be lowered and it increased the mean lung tissue volume obtained by SPECT from 3.09±0.49 l for baseline to 3.67±0.62 l for 10 cmH 2 O (p 2 O (p 2 O), respectively. The PEEP also increased the lung tissue volume to 3.68±0.68 l for 10 cmH 2 O as compared with the baseline (p 2 O PEEP. The lung tissue volume obtained by SPECT showed a positive correlation with functional residual capacity measured by the He dilution method (r=0.91, p 99m Tc-labeled red blood cells. The L/H ratio decreased after either the CNP or PEEP, suggesting a decrease in the blood volume per unit lung volume. However, it was suggested that the total pulmonary blood volume increased slightly either on the CNP (+7.4% for 10 cmH 2 O, p 2 O,p<0.05) when we extrapolated the L/H ratio to the whole lungs by multiplying the lung tissue volume obtained by SPECT. We concluded that SPECT could offer access to the estimation of lung volume and pulmonary blood volume in vivo. (author)

  9. PET functional volume delineation: a robustness and repeatability study

    International Nuclear Information System (INIS)

    Hatt, Mathieu; Cheze-le Rest, Catherine; Albarghach, Nidal; Pradier, Olivier; Visvikis, Dimitris

    2011-01-01

    Current state-of-the-art algorithms for functional uptake volume segmentation in PET imaging consist of threshold-based approaches, whose parameters often require specific optimization for a given scanner and associated reconstruction algorithms. Different advanced image segmentation approaches previously proposed and extensively validated, such as among others fuzzy C-means (FCM) clustering, or fuzzy locally adaptive bayesian (FLAB) algorithm have the potential to improve the robustness of functional uptake volume measurements. The objective of this study was to investigate robustness and repeatability with respect to various scanner models, reconstruction algorithms and acquisition conditions. Robustness was evaluated using a series of IEC phantom acquisitions carried out on different PET/CT scanners (Philips Gemini and Gemini Time-of-Flight, Siemens Biograph and GE Discovery LS) with their associated reconstruction algorithms (RAMLA, TF MLEM, OSEM). A range of acquisition parameters (contrast, duration) and reconstruction parameters (voxel size) were considered for each scanner model, and the repeatability of each method was evaluated on simulated and clinical tumours and compared to manual delineation. For all the scanner models, acquisition parameters and reconstruction algorithms considered, the FLAB algorithm demonstrated higher robustness in delineation of the spheres with low mean errors (10%) and variability (5%), with respect to threshold-based methodologies and FCM. The repeatability provided by all segmentation algorithms considered was very high with a negligible variability of <5% in comparison to that associated with manual delineation (5-35%). The use of advanced image segmentation algorithms may not only allow high accuracy as previously demonstrated, but also provide a robust and repeatable tool to aid physicians as an initial guess in determining functional volumes in PET. (orig.)

  10. Going the Extra Mile: Improved Survival for Pancreatic Cancer Patients Traveling to High-volume Centers.

    Science.gov (United States)

    Lidsky, Michael E; Sun, Zhifei; Nussbaum, Daniel P; Adam, Mohamed A; Speicher, Paul J; Blazer, Dan G

    2017-08-01

    This study compares outcomes following pancreaticoduodenectomy (PD) for patients treated at local, low-volume centers and those traveling to high-volume centers. Although outcomes for PD are superior at high-volume institutions, not all patients live in proximity to major medical centers. Theoretical advantages for undergoing surgery locally exist. The 1998 to 2012 National Cancer Data Base was queried for T1-3N0-1M0 pancreatic adenocarcinoma patients who underwent PD. Travel distances to treatment centers were calculated. Overlaying the upper and lower quartiles of travel distance with institutional volume established short travel/low-volume (ST/LV) and long travel/high-volume (LT/HV) cohorts. Overall survival was evaluated. Of 7086 patients, 773 ST/LV patients traveled ≤6.3 (median 3.2) miles to centers performing ≤3.3 PDs yearly, and 758 LT/HV patients traveled ≥45 (median 97.3) miles to centers performing ≥16 PDs yearly. LT/HV patients had higher stage disease (P travel to a high-volume center remained associated with reduced long-term mortality (hazard ratio 0.75, P travel burden, patients treated at high-volume centers had improved perioperative outcomes, short-term mortality, and overall survival. These data support ongoing efforts to centralize care for patients undergoing PD.

  11. Estimated maximal and current brain volume predict cognitive ability in old age

    Science.gov (United States)

    Royle, Natalie A.; Booth, Tom; Valdés Hernández, Maria C.; Penke, Lars; Murray, Catherine; Gow, Alan J.; Maniega, Susana Muñoz; Starr, John; Bastin, Mark E.; Deary, Ian J.; Wardlaw, Joanna M.

    2013-01-01

    Brain tissue deterioration is a significant contributor to lower cognitive ability in later life; however, few studies have appropriate data to establish how much influence prior brain volume and prior cognitive performance have on this association. We investigated the associations between structural brain imaging biomarkers, including an estimate of maximal brain volume, and detailed measures of cognitive ability at age 73 years in a large (N = 620), generally healthy, community-dwelling population. Cognitive ability data were available from age 11 years. We found positive associations (r) between general cognitive ability and estimated brain volume in youth (male, 0.28; females, 0.12), and in measured brain volume in later life (males, 0.27; females, 0.26). Our findings show that cognitive ability in youth is a strong predictor of estimated prior and measured current brain volume in old age but that these effects were the same for both white and gray matter. As 1 of the largest studies of associations between brain volume and cognitive ability with normal aging, this work contributes to the wider understanding of how some early-life factors influence cognitive aging. PMID:23850342

  12. A computational study on the performance of a solar air-conditioning system with a partitioned storage tank

    International Nuclear Information System (INIS)

    Li, Z.F.; Sumathy, K.

    2003-01-01

    This paper reports the performance of a modified solar powered air-conditioning system, which is integrated with a partitioned storage tank. In addition, the effect of two main parameters that influence the system performance is presented and discussed. The study shows that by partitioning the storage tank, the solar cooling effect can be realized much earlier and could attain a total solar cooling COP of 12% higher compared to the conventional whole-tank mode. Simulation results also indicate that there exists an optimum ratio of storage tank volume over collector area

  13. Fort Hood Solar Total Energy Project. Volume II. Preliminary design. Part 2. System performance and supporting studies. Final report

    Energy Technology Data Exchange (ETDEWEB)

    None,

    1979-01-01

    The preliminary design developed for the Solar Total Energy System to be installed at Fort Hood, Texas, is presented. System performance analysis and evaluation are described. Feedback of completed performance analyses on current system design and operating philosophy is discussed. The basic computer simulation techniques and assumptions are described and the resulting energy displacement analysis is presented. Supporting technical studies are presented. These include health and safety and reliability assessments; solar collector component evaluation; weather analysis; and a review of selected trade studies which address significant design alternatives. Additional supporting studies which are generally specific to the installation site are reported. These include solar availability analysis; energy load measurements; environmental impact assessment; life cycle cost and economic analysis; heat transfer fluid testing; meteorological/solar station planning; and information dissemination. (WHK)

  14. Evaluation of a cumulative SUV-volume histogram method for parameterizing heterogeneous intratumoural FDG uptake in non-small cell lung cancer PET studies

    International Nuclear Information System (INIS)

    Velden, Floris H.P. van; Cheebsumon, Patsuree; Yaqub, Maqsood; Hoekstra, Otto S.; Lammertsma, Adriaan A.; Boellaard, Ronald; Smit, Egbert F.

    2011-01-01

    Standardized uptake values (SUV) are commonly used for quantification of whole-body [ 18 F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) studies. Changes in SUV following therapy, however, only provide a proper measure of response in case of homogeneous FDG uptake in the tumour. The purpose of this study was therefore to implement and characterize a method that enables quantification of heterogeneity in tumour FDG uptake. Cumulative SUV-volume histograms (CSH), describing % of total tumour volume above % threshold of maximum SUV (SUV max ), were calculated. The area under a CSH curve (AUC) is a quantitative index of tumour uptake heterogeneity, with lower AUC corresponding to higher degrees of heterogeneity. Simulations of homogeneous and heterogeneous responses were performed to assess the value of AUC-CSH for measuring uptake and/or response heterogeneity. In addition, partial volume correction and image denoising was applied prior to calculating AUC-CSH. Finally, the method was applied to a number of human FDG scans. Partial volume correction and noise reduction improved CSH curves. Both simulations and clinical examples showed that AUC-CSH values corresponded with level of tumour heterogeneity and/or heterogeneity in response. In contrast, this correspondence was not seen with SUV max alone. The results indicate that the main advantage of AUC-CSH above other measures, such as 1/COV (coefficient of variation), is the possibility to measure or normalize AUC-CSH in different ways. AUC-CSH might be used as a quantitative index of heterogeneity in tracer uptake. In response monitoring studies it can be used to address heterogeneity in response. (orig.)

  15. Baseline design of an OTEC pilot plantship. Volume A. Detailed report. [Performance analysis of OTEC power plant

    Energy Technology Data Exchange (ETDEWEB)

    George, J. F.; Richards, D.; Perini, L. L.

    1979-05-01

    The Applied Physics Laboratory (APL) of the Johns Hopkins University has engineered a baseline design of an Ocean Thermal Energy Conversion (OTEC) pilot plantship. The work was sponsored jointly by the Department of Energy and the US Maritime Administration of the Department of Commerce. The design, drawings, specifications, supporting calculations, and narrative documentation are available through APL for use by the Government and industry for the acquisition of a pilot OTEC system. The baseline design features a platform that is configured to produce up to 20 MW(e) (net) power, using low-cost folded-tube aluminum heat exchangers, while it grazes slowly in tropical waters where the thermal gradient is greatest and the ocean environment is least severe. The design was developed by a team of contractors whose capabilities provided a systems approach to the design process. The work is documented in three volumes. Volume A is the Detailed report, which develops the design rationale, summarizes important calculations, outlines areas for future work, and presents a study of system costs. Volumes B and C, respectively, contain the engineering drawings and specifications.

  16. Ultrasound and Histologic Examination after Subcutaneous Injection of Two Volumizing Hyaluronic Acid Fillers: A Preliminary Study

    Science.gov (United States)

    Besse, Stéphanie; Sarazin, Didier; Quinodoz, Pierre; Elias, Badwi; Safa, Marva; Vandeputte, Joan

    2017-01-01

    Background: This study examined the influence of hyaluronic acid (HA) crosslinking technology on the ultrasound and histologic behavior of HA fillers designed for subcutaneous injection. Methods: One subject received subcutaneous injections of 0.25 ml Cohesive Polydensified Matrix (CPM) and Vycross volumizing HA in tissue scheduled for abdominoplasty by bolus and retrograde fanning techniques. Ultrasound analyses were performed on days 0 and 8 and histologic analyses on days 0 and 21 after injection. A series of simple rheologic tests was also performed. Results: Day 0 ultrasound images after bolus injection showed CPM and Vycross as hypoechogenic papules in the hypodermis. CPM appeared little changed after gentle massage, whereas Vycross appeared more hyperechogenic and diminished in size. Ultrasound images at day 8 were similar. On day 0, both gels appeared less hypoechogenic after retrograde fanning than after bolus injection. Vycross was interspersed with hyperechogenic areas (fibrous septa from the fat network structure) and unlike CPM became almost completely invisible after gentle massage. On day 8, CPM appeared as a hypoechogenic pool and Vycross as a long, thin rod. Day 0 histologic findings confirmed ultrasound results. Day 21 CPM histologic findings showed a discrete inflammatory reaction along the injection row after retrograde fanning. Vycross had a more pronounced inflammatory reaction, particularly after retrograde fanning, with macrophages and giant cells surrounding the implant. Rheologic tests showed CPM to have greater cohesivity and resistance to traction forces than Vycross. Conclusions: CPM HA volumizer appears to maintain greater tissue integrity than Vycross after subcutaneous injection with less inflammatory activity. PMID:28280664

  17. Free-volume study of ethylene - vinyl alcohol copolymer evaluated through positronium lifetime measurement

    International Nuclear Information System (INIS)

    Ito, K.; Hong-ling Li; Ujihira, Y.; Nomura, K.; Saito, Y.; Yamamoto, T.; Nishihara, Y.

    2003-01-01

    The free-volume, of size ranging from 0.2 to 0.4 nm in radius, in an ethylene-vinyl alcohol copolymer was estimated using positronium lifetime measurement to elucidate the dependence of oxygen permeability on the free-volume size and fraction, on the ethylene content and on the crystallinity. The permeability and the free-volume fraction with varying the ethylene content were well related and the relation was interpreted based on the free-volume theory near below and above the glass transition temperature. On the other hand, the crystallinity significantly influenced the fraction of the amorphous region, where the free-volume hole exists, along with a slight change of the free-volume size. The variation of the permeability with the crystalline degree cannot be explained from the averaged free-volume fraction estimated by the whole volume of the polymer, but the permeability correlated with the free-volume size apparently. (author)

  18. Feasibility of disposal of high-level radioactive waste into the seabed. Volume 3: Geoscience characterization studies

    International Nuclear Information System (INIS)

    Shephard, L.E.; Auffret, G.A.; Buckley, D.E.; Schuettenhelm, R.T.E.; Searle, R.C.

    1988-01-01

    One of the options suggested for disposal of high-level radioactive waste resulting from the generation of nuclear power is burial beneath the deep ocean floor in geologically stable sediment formations which have no economic value. The 8-volume series provides an assessment of the technical feasibility and radiological safety of this disposal concept based on the results obtained by ten years of co-operation and information exchange among the Member countries participating in the NEA Seabed Working Group. This report summarizes the results of a study performed to establish if, on the basis of available data, sites may be found that will satisfy the geoscience requirements for a potential subseabed high-level waste repository

  19. Human Performance in Continuous Operations. Volume 3. Technical Documentation

    Science.gov (United States)

    1980-03-01

    completed for the U. S. Commander, V Corps. Artillery, by Manning (1978). Manning collected information which bears on the following three questions: 0 Can...performance data were not collected in these pre- liminary studies. Field Studies of Continuous Tank OperationsLI __ _ _ __ _ _ _ To simulate a combat...on routine, monotonous tasks tends A show rapid and severe decrement after peri- odk of more than 24 hours without sleep. I Increasing task complexity

  20. SLSF loop handling system. Volume I. Structural analysis

    International Nuclear Information System (INIS)

    Ahmed, H.; Cowie, A.; Ma, D.

    1978-10-01

    SLSF loop handling system was analyzed for deadweight and postulated dynamic loading conditions, identified in Chapters II and III in Volume I of this report, using a linear elastic static equivalent method of stress analysis. Stress analysis of the loop handling machine is presented in Volume I of this report. Chapter VII in Volume I of this report is a contribution by EG and G Co., who performed the work under ANL supervision

  1. A Monte Carlo study of the impact of the choice of rectum volume definition on estimates of equivalent uniform doses and the volume parameter

    International Nuclear Information System (INIS)

    Kvinnsland, Yngve; Muren, Ludvig Paul; Dahl, Olav

    2004-01-01

    Calculations of normal tissue complication probability (NTCP) values for the rectum are difficult because it is a hollow, non-rigid, organ. Finding the true cumulative dose distribution for a number of treatment fractions requires a CT scan before each treatment fraction. This is labour intensive, and several surrogate distributions have therefore been suggested, such as dose wall histograms, dose surface histograms and histograms for the solid rectum, with and without margins. In this study, a Monte Carlo method is used to investigate the relationships between the cumulative dose distributions based on all treatment fractions and the above-mentioned histograms that are based on one CT scan only, in terms of equivalent uniform dose. Furthermore, the effect of a specific choice of histogram on estimates of the volume parameter of the probit NTCP model was investigated. It was found that the solid rectum and the rectum wall histograms (without margins) gave equivalent uniform doses with an expected value close to the values calculated from the cumulative dose distributions in the rectum wall. With the number of patients available in this study the standard deviations of the estimates of the volume parameter were large, and it was not possible to decide which volume gave the best estimates of the volume parameter, but there were distinct differences in the mean values of the values obtained

  2. Liquidity Effects on the Simultaneity of Trading Volume and Order Imbalance

    Directory of Open Access Journals (Sweden)

    Erman Denny Arfianto

    2016-10-01

    Full Text Available The purpose of this research is to analyze the simultaneity between trading volume and order imbalance, the influence of past performance, market risk, market capitalization, tick size to the trading volume and the influence of tick size, depth and bid-ask spread to the order imbalance of companies that were listed on LQ 45 index. The samples in this research were selected by using the purposive sampling method with some selected criteria. Fifty-five companies listed on 2014’s LQ 45 index were chosen as the sample. The results showed that the trading volume is simultaneously related to the order imbalance; past performance, market risk, and market capitalization have the positive and significant effect to the trading volume; tick size has the negative and significant effect to the trading volume; the order imbalance has the negative and insignificant effect to the trading volume; tick size, depth, bid-ask spread, and trading volume have no significant effect to the order imbalance.

  3. Effect of volume loading on the Frank-Starling relation during reductions in central blood volume in heat-stressed humans

    DEFF Research Database (Denmark)

    Bundgaard-Nielsen, Morten; Wilson, T E; Seifert, Thomas

    2010-01-01

    During reductions in central blood volume while heat stressed, a greater decrease in stroke volume (SV) for a similar decrease in ventricular filling pressure, compared to normothermia, suggests that the heart is operating on a steeper portion of a Frank-Starling curve. If so, volume loading...... of heat-stressed individuals would shift the operating point to a flatter portion of the heat stress Frank-Starling curve thereby attenuating the reduction in SV during subsequent decreases in central blood volume. To investigate this hypothesis, right heart catheterization was performed in eight males...... from whom pulmonary capillary wedge pressure (PCWP), central venous pressure and SV (via thermodilution) were obtained while central blood volume was reduced via lower-body negative pressure (LBNP) during normothermia, whole-body heating (increase in blood temperature 1 degrees C), and during whole...

  4. A feasibility study for the design of a simulated radioactive waste repository facility. Volume 1 Text-References

    International Nuclear Information System (INIS)

    Mott; Hay; Anderson.

    1987-01-01

    The report is in two volumes: Volume 1 contains the main text and the references, and volume 2, all the figures and tables. The great majority of published concepts for the disposal of heat generating radioactive waste envisage the emplacement of waste packages in boreholes backfilled with an engineered material described as the buffer. The need for a full scale experimental programme to investigate buffer placement and performance was identified, and this report describes the first stage in the development of that programme. The nature of candidate buffer materials and the factors defining their behaviour have been reviewed and the nature of a buffer material selection and testing programme have been outlined. The properties of crystalline rocks, saliferous formations and clay host materials have been reviewed and the complex interactions between them have been identified. The difficulty of modelling these properties and the interaction between buffer and host materials has been discussed and the instrumentation requirements for measuring this interaction have been outlined. A limited amount of thermomechanical analysis has been performed to give a preliminary indication of the parameters of major significance in selection of instrumentation and modelling materials. It has been concluded that a complete simulation of host material properties is not presently viable, although it may be attainable for some crystalline rock types. Alternative strategies for assessment of the host/buffer interaction are suggested

  5. Dosimetric impact of the variation of the prostate volume and shape between pretreatment planning and treatment procedure

    International Nuclear Information System (INIS)

    Beaulieu, Luc; Aubin, Sylviane; Taschereau, Richard; Pouliot, Jean; Vigneault, Eric

    2002-01-01

    Purpose: The goal of this study is to evaluate the dosimetric impact on a pretreatment planning of prostatic volume and shape variations occurring between the moment of the volume study (preplanning) and just before a transperineal permanent seed implant procedure. Such variations could be an obvious source of misplacement of the seeds relative to the prostate gland and organs at risk. Other sources of dosimetric uncertainties, such as misplacement due to the procedure itself or edema, are eliminated by looking at these variations before the implant procedure. Methods and Materials: For 35 clinical cases, prostate contours were taken at preplanning time as well as in the operating room (OR) minutes before the procedure. Comparison of shape and volume between the two sets was made. The impact on V100 was evaluated by placing the seeds in their planned positions in the new volume (clinical situation) and also by performing a new plan with the second set of contours to simulate an intraoperative approach. Results: The volume taken in the OR remained unchanged compared to the pretreatment planning volume in only 37% of the cases. While on average the dose coverage loss from pretreatment planning due to a combination of variations of volume and shape was small at 5.7%, a V100 degradation of up to 20.9% was observed in extreme cases. Even in cases in which no changes in volume were observed, changes in shape occurred and strongly affected implant dosimetry. Conclusions: Variations of volume and shape between pretreatment planning and the implant procedure can have a strong impact on the dosimetry if the planning and the implant procedure are not performed on the same day. This is an argument in favor of performing implant dosimetry in the OR

  6. Variation in Annual Volume at a University Hospital Does Not Predict Mortality for Pancreatic Resections

    Directory of Open Access Journals (Sweden)

    Rita A. Mukhtar

    2008-01-01

    Full Text Available Annual volume of pancreatic resections has been shown to affect mortality rates, prompting recommendations to regionalize these procedures to high-volume hospitals. Implementation has been difficult, given the paucity of high-volume centers and the logistical hardships facing patients. Some studies have shown that low-volume hospitals achieve good outcomes as well, suggesting that other factors are involved. We sought to determine whether variations in annual volume affected patient outcomes in 511 patients who underwent pancreatic resections at the University of California, San Francisco between 1990 and 2005. We compared postoperative mortality and complication rates between low, medium, or high volume years, designated by the number of resections performed, adjusting for patient characteristics. Postoperative mortality rates did not differ between high volume years and medium/low volume years. As annual hospital volume of pancreatic resections may not predict outcome, identification of actual predictive factors may allow low-volume centers to achieve excellent outcomes.

  7. Hippocampus and amygdala volumes in patients with vaginismus.

    Science.gov (United States)

    Atmaca, Murad; Baykara, Sema; Ozer, Omer; Korkmaz, Sevda; Akaslan, Unsal; Yildirim, Hanefi

    2016-06-22

    To compare hippocampus and amygdala volumes of patients with vaginismus with those of healthy control subjects. Magnetic resonance imaging was performed on ten patients with vaginismus and ten control subjects matched for age and gender. Volumes of the hippocampus and amygdala were blindly measured. We found that the mean right amygdala volume of patients with vaginismus were smaller than that of the healthy controls. With regard to hippocampus volumes, the mean left and right hippocampus volumes were smaller than those of the healthy controls. Our present findings suggest that there have been hippocampus and amygdala structural abnormalities in patients with vaginismus. These changes provide the notion that vaginismus may be a fear-related condition.

  8. Trends in Penile Prosthetics: Influence of Patient Demographics, Surgeon Volume, and Hospital Volume on Type of Penile Prosthesis Inserted in New York State.

    Science.gov (United States)

    Kashanian, James A; Golan, Ron; Sun, Tianyi; Patel, Neal A; Lipsky, Michael J; Stahl, Peter J; Sedrakyan, Art

    2018-02-01

    Penile prostheses (PPs) are a discrete, well-tolerated treatment option for men with medical refractory erectile dysfunction. Despite the increasing prevalence of erectile dysfunction, multiple series evaluating inpatient data have found a decrease in the frequency of PP surgery during the past decade. To investigate trends in PP surgery and factors affecting the choice of different PPs in New York State. This study used the New York State Department of Health Statewide Planning and Research Cooperative (SPARCS) data cohort that includes longitudinal information on hospital discharges, ambulatory surgery, emergency department visits, and outpatient services. Patients older than 18 years who underwent inflatable or non-inflatable PP insertion from 2000 to 2014 were included in the study. Influence of patient demographics, surgeon volume, and hospital volume on type of PP inserted. Since 2000, 14,114 patients received PP surgery in New York State; 12,352 PPs (88%) were inflatable and 1,762 (12%) were non-inflatable, with facility-level variation from 0% to 100%. There was an increasing trend in the number of annual procedures performed, with rates of non-inflatable PP insertion decreasing annually (P New York State and the results might not be generalizable to men in other states. Also, patient preference was not accounted for in these analyses, which can play a role in PP selection. During the past 14 years, there has been an increasing trend in inflatable PP surgery for the management of erectile dysfunction. Most procedures are performed in the ambulatory setting and not previously captured by prior studies using inpatient data. Kashanian JA, Golan R, Sun T, et al. Trends in Penile Prosthetics: Influence of Patient Demographics, Surgeon Volume, and Hospital Volume on Type of Penile Prosthesis Inserted in New York State. J Sex Med 2018;15:245-250. Copyright © 2017 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  9. Performance of SBR for the treatment of textile dye wastewater: Optimization and kinetic studies

    Directory of Open Access Journals (Sweden)

    S. Sathian

    2014-06-01

    Full Text Available In this work, sequential batch reactor (SBR was employed for the treatment of textile dye wastewater. The performance of four white rot fungi (WRF viz. Coriolus versicolor, Pleurotus floridanus, Ganoderma lucidum and Trametes pubescens was evaluated in pure and mixed combinations in terms of decolorization. From the results it was found that the combination of Pleurotus floridanus, Ganoderma lucidum and Trametes pubescens was best and they were used in the SBR. The process parameters like air flow rate, sludge retention time (SRT and cycle period were optimized using response surface methodology (RSM. At these optimized conditions, treatment of textile dye wastewater was carried out at various initial dye wastewater concentration and hydraulic retention time. The performance of SBR was analyzed in terms of decolorization, COD reduction and sludge volume index (SVI. From the results it was found that a maximum decolorization and COD reduction of 71.3% and 79.4%, respectively, was achieved in the SBR at an organic loading rate of 0.165 KgCOD/m3 d. The sludge volume index (SVI was found to be low in the range of 90–103 mL/g. The kinetic study was carried out using a first order based model and the degradation follows the first order system.

  10. Reduced striatal volumes in Parkinson’s disease: a magnetic resonance imaging study

    Directory of Open Access Journals (Sweden)

    Pitcher Toni L

    2012-08-01

    Full Text Available Abstract Background The presence and extent of structural changes in the brain as a consequence of Parkinson’s disease (PD is still poorly understood. Methods High-resolution 3-tesla T1-weighted structural magnetic resonance images in sixty-five PD and 27 age-matched healthy control participants were examined. Putamen, caudate, and intracranial volumes were manually traced in the axial plane of 3D reconstructed images. Striatal nuclei volumes were normalized to intracranial volume for statistical comparison. Disease status was assessed using the Unified Parkinson’s Disease Rating Scale and Hoehn and Yahr scale. Cognitive status was assessed using global status tests and detailed neuropsychological testing. Results Both caudate and putamen volumes were smaller in PD brains compared to controls after adjusting for age and gender. Caudate volumes were reduced by 11% (p = 0.001 and putamen volumes by 8.1% (p = 0.025. PD striatal volumes were not found to be significantly correlated with cognitive or motor decline. Conclusion Small, but significant reductions in the volume of both the caudate and putamen occur in PD brains. These reductions are independent of the effects of age and gender, however the relation of these reductions to the functional loss of dopamine, which is characteristic of PD, remains unclear.

  11. Experimental studies for the development of a new method for stroke volume measuring using X-ray videodensitometry

    International Nuclear Information System (INIS)

    Odenthal, H.J.

    1982-01-01

    Quantitative videodensitometry was studied with a view to its possible application as a new, non-invasive method of measuring cardiac stroke volume. To begin with, the accuracy of roentgen volumetric measurements was determined. After this, blood volume variations were measured by densitometry in five animal experiments. The findings were compared with the volumes measured by a flowmeter in the pulmonary artery. The total stroke volume was found to be proportional to the difference between the maximum and mean densitometric volume. A comparison between videodensitometry and other non-invasive methods showed that, in a stable circulatory system, the results of videodensitometry are equally reliable as, or even more reliable than, those of the conventional methods. (orig./MG) [de

  12. Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992. Volume 1, Third comparison with 40 CFR 191, Subpart B

    Energy Technology Data Exchange (ETDEWEB)

    1992-12-01

    Before disposing of transuranic radioactive wastes in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments of the WIPP for the DOE to provide interim guidance while preparing for final compliance evaluations. This volume contains an overview of WIPP performance assessment and a preliminary comparison with the long-term requirements of the Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B).

  13. Predictive tool of energy performance of cold storage in agrifood industries: The Portuguese case study

    International Nuclear Information System (INIS)

    Nunes, José; Neves, Diogo; Gaspar, Pedro D.; Silva, Pedro D.; Andrade, Luís P.

    2014-01-01

    Highlights: • A predictive tool for assessment of the energy performance in agrifood industries that use cold storage is developed. • The correlations used by the predictive tool result from the greatest number of data sets collected to date in Portugal. • Strong relationships between raw material, energy consumption and volume of cold stores were established. • Case studies were analyzed that demonstrate the applicability of the tool. • The tool results are useful in the decision-making process of practice measures for the improvement of energy efficiency. - Abstract: Food processing and conservation represent decisive factors for the sustainability of the planet given the significant growth of the world population in the last decades. Therefore, the cooling process during the manufacture and/or storage of food products has been subject of study and improvement in order to ensure the food supply with good quality and safety. A predictive tool for assessment of the energy performance in agrifood industries that use cold storage is developed in order to contribute to the improvement of the energy efficiency of this industry. The predictive tool is based on a set of characteristic correlated parameters: amount of raw material annually processed, annual energy consumption and volume of cold rooms. Case studies of application of the predictive tool consider industries in the meat sector, specifically slaughterhouses. The results obtained help on the decision-making of practice measures for improvement of the energy efficiency in this industry

  14. Procedures for treating common cause failures in safety and reliability studies: Volume 2, Analytic background and techniques: Final report

    International Nuclear Information System (INIS)

    Mosleh, A.; Fleming, K.N.; Parry, G.W.; Paula, H.M.; Worledge, D.H.; Rasmuson, D.M.

    1988-12-01

    This report presents a framework for the inclusion of the impact of common cause failures in risk and reliability evaluations. Common cause failures are defined as that subset of dependent failures for which causes are not explicitly included in the logic model as basic events. The emphasis here is on providing procedures for a practical, systematic approach that can be used to perform and clearly document the analysis. The framework and the methods discussed for performing the different stages of the analysis integrate insights obtained from engineering assessments of the system and the historical evidence from multiple failure events into a systematic, reproducible, and defensible analysis. This document, Volume 2, contains a series of appendices that provide additional background and methodological detail on several important topics discussed in Volume 1

  15. Emphysema lung lobe volume reduction: effects on the ipsilateral and contralateral lobes

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Matthew S.; Kim, Hyun J.; Abtin, Fereidoun G.; Galperin-Aizenberg, Maya; Pais, Richard; Da Costa, Irene G.; Ordookhani, Arash; Chong, Daniel; Ni, Chiayi; McNitt-Gray, Michael F.; Goldin, Jonathan G. [David Geffen School of Medicine at UCLA, Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, Los Angeles, CA (United States); Strange, Charlie [Medical University of South Carolina, Department of Pulmonary and Critical Care Medicine, Columbia, SC (United States); Tashkin, Donald P. [David Geffen School of Medicine at UCLA, Division of Pulmonary and Critical Care Medicine, Los Angeles, CA (United States)

    2012-07-15

    To investigate volumetric and density changes in the ipsilateral and contralateral lobes following volume reduction of an emphysematous target lobe. The study included 289 subjects with heterogeneous emphysema, who underwent bronchoscopic volume reduction of the most diseased lobe with endobronchial valves and 132 untreated controls. Lobar volume and low-attenuation relative area (RA) changes post-procedure were measured from computed tomography images. Regression analysis (Spearman's rho) was performed to test the association between change in the target lobe volume and changes in volume and density variables in the other lobes. The target lobe volume at full inspiration in the treatment group had a mean reduction of -0.45 L (SE = 0.034, P < 0.0001), and was associated with volume increases in the ipsilateral lobe (rho = -0.68, P < 0.0001) and contralateral lung (rho = -0.16, P = 0.006), and overall reductions in expiratory RA (rho = 0.31, P < 0.0001) and residual volume (RV)/total lung capacity (TLC) (rho = 0.13, P = 0.03). When the volume of an emphysematous target lobe is reduced, the volume is redistributed primarily to the ipsilateral lobe, with an overall reduction. Image-based changes in lobar volumes and densities indicate that target lobe volume reduction is associated with statistically significant overall reductions in air trapping, consistent with expansion of the healthier lung. (orig.)

  16. Emphysema lung lobe volume reduction: effects on the ipsilateral and contralateral lobes

    International Nuclear Information System (INIS)

    Brown, Matthew S.; Kim, Hyun J.; Abtin, Fereidoun G.; Galperin-Aizenberg, Maya; Pais, Richard; Da Costa, Irene G.; Ordookhani, Arash; Chong, Daniel; Ni, Chiayi; McNitt-Gray, Michael F.; Goldin, Jonathan G.; Strange, Charlie; Tashkin, Donald P.

    2012-01-01

    To investigate volumetric and density changes in the ipsilateral and contralateral lobes following volume reduction of an emphysematous target lobe. The study included 289 subjects with heterogeneous emphysema, who underwent bronchoscopic volume reduction of the most diseased lobe with endobronchial valves and 132 untreated controls. Lobar volume and low-attenuation relative area (RA) changes post-procedure were measured from computed tomography images. Regression analysis (Spearman's rho) was performed to test the association between change in the target lobe volume and changes in volume and density variables in the other lobes. The target lobe volume at full inspiration in the treatment group had a mean reduction of -0.45 L (SE = 0.034, P < 0.0001), and was associated with volume increases in the ipsilateral lobe (rho = -0.68, P < 0.0001) and contralateral lung (rho = -0.16, P = 0.006), and overall reductions in expiratory RA (rho = 0.31, P < 0.0001) and residual volume (RV)/total lung capacity (TLC) (rho = 0.13, P = 0.03). When the volume of an emphysematous target lobe is reduced, the volume is redistributed primarily to the ipsilateral lobe, with an overall reduction. Image-based changes in lobar volumes and densities indicate that target lobe volume reduction is associated with statistically significant overall reductions in air trapping, consistent with expansion of the healthier lung. (orig.)

  17. Urban area and green space: volume estimation using medium resolution satellite imagery

    Science.gov (United States)

    Handayani, H. H.

    2017-12-01

    The latest revision of the UN World Urbanization Prospects predicts the world's urban population to increase by 1.4 billion between 2010 and 2030, 60% of the population will live in cities. Consequently, this expansion affects the existence of ecosystem services in the context of sustainability environment. Green space is a focal point of the ecological system and is affected by the urbanization process. The green space has essential functions in cleaning the water, adjusting the microclimate, eliminating noise, and beautifying the surrounding makes the green quantity as well as quality very vital to its existence. The urban expansion leads the growth into vertical development. Therefore, the third dimension using urban volume as an indicator of vertical development is introduced. Therefore, this study estimates the urban and green volume by using medium resolution remote sensing. Surabaya is used as a case study since the city has grown up significantly in both of population and capital investment in this decade. Here, urban and green volume is investigated by ALOS datasets with urban referring built-up. Also, we examine the area with low and high green volume by performing hot and cold spots analysis. The average of built-up volume reaches 173.05 m3/pixel presented by the building for a residential single house with the height less than 7m. The average of green volume is 14.74m3/pixel performed by the vegetation with the height generally 0.6 to 1m which is frequently planted in the backyard of house. However, the ratio of green volume to the built-up volume shows a small portion which is around 8.52%. Therefore, we identify the hot and cold spots, we evaluate 5 areas having cold spot regarding lack of green volume. The two locations of cold spot are located in the northern part and another is in the southern part. Those areas have high number of built-up volume which is in particularly as sub-CBD area. We emphasize that the improvement of green quantity is needed

  18. Advanced Transportation System Studies. Technical Area 3: Alternate Propulsion Subsystems Concepts. Volume 3; Program Cost Estimates

    Science.gov (United States)

    Levack, Daniel J. H.

    2000-01-01

    The objective of this contract was to provide definition of alternate propulsion systems for both earth-to-orbit (ETO) and in-space vehicles (upper stages and space transfer vehicles). For such propulsion systems, technical data to describe performance, weight, dimensions, etc. was provided along with programmatic information such as cost, schedule, needed facilities, etc. Advanced technology and advanced development needs were determined and provided. This volume separately presents the various program cost estimates that were generated under three tasks: the F- IA Restart Task, the J-2S Restart Task, and the SSME Upper Stage Use Task. The conclusions, technical results , and the program cost estimates are described in more detail in Volume I - Executive Summary and in individual Final Task Reports.

  19. Subcortical volume and cortical surface architecture in women with acute and remitted anorexia nervosa: An exploratory neuroimaging study.

    Science.gov (United States)

    Miles, Amy E; Voineskos, Aristotle N; French, Leon; Kaplan, Allan S

    2018-04-13

    Anorexia nervosa (AN) is a highly heritable psychiatric disorder characterized by starvation and emaciation and associated with changes in brain structure. The precise nature of these changes remains unclear, as does their developmental time course and capacity for reversal with weight-restoration. In this comprehensive neuroimaging study, we sought to characterize these changes by measuring subcortical volume and cortical surface architecture in women with acute and remitted AN. Structural magnetic resonance imaging data was acquired from underweight women with a current diagnosis of AN (acAN: n = 23), weight-recovered women with a past diagnosis of AN (recAN: n = 24), and female controls (HC: n = 24). Subcortical segmentation and cortical surface reconstruction were performed with FreeSurfer 6.0.0, and group differences in regional volume and vertex-wise, cortex-wide thickness, surface area, and local gyrification index (LGI), a measure of folding, were tested with separate univariate analyses of covariance. Mean hippocampal and thalamic volumes were significantly reduced in acAN participants, as was mean cortical thickness in four frontal and temporal clusters. Mean LGI was significantly reduced in acAN and recAN participants in five frontal and parietal clusters. No significant group differences in cortical surface area were detected. Reductions in subcortical volume, cortical thickness, and right postcentral LGI were unique to women with acute AN, indicating state-dependence and pointing towards cellular remodeling and sulcal widening as consequences of disease manifestation. Reductions in bilateral frontal LGI were observed in women with acute and remitted AN, suggesting a role of atypical neurodevelopment in disease vulnerability. Copyright © 2018. Published by Elsevier Ltd.

  20. Free volume changes in mechanically milled PS and PC studied by positron annihilation lifetime spectroscopy (PALS)

    NARCIS (Netherlands)

    Günther-Schade, K.; Castricum, H.L.; Ziegler, H.J.; Bakker, H.; Faupel, F.

    2004-01-01

    The effect of mechanical milling on free volume was studied by means of positron annihilation lifetime spectroscopy (PALS) in polystyrene (PS) as a typical brittle polymer and in polycarbonate (PC) as a tough representative. Long-time milling increases the free volume, while a decrease is observed

  1. Studies on the partial specific volume of a poly(ethylene glycol) derivative in different solvent systems

    NARCIS (Netherlands)

    Tziatzios, C.; Precup, A.A.; Weidl, C.H.; Schubert, U.S.; Schuck, P.; Durchschlag, H.; Mächtle, W.; Broek, van den J.A.; Schubert, D.

    2002-01-01

    The specific volume of charged supramolecular compounds dissolved in organic solvents varies considerably with the solvent system applied; in addition, it is influenced by the presence of salt. In this study we determined the specific volume of an uncharged molecule from the same molar mass range in

  2. The design of the run Clever randomized trial: running volume, -intensity and running-related injuries.

    Science.gov (United States)

    Ramskov, Daniel; Nielsen, Rasmus Oestergaard; Sørensen, Henrik; Parner, Erik; Lind, Martin; Rasmussen, Sten

    2016-04-23

    Injury incidence and prevalence in running populations have been investigated and documented in several studies. However, knowledge about injury etiology and prevention is needed. Training errors in running are modifiable risk factors and people engaged in recreational running need evidence-based running schedules to minimize the risk of injury. The existing literature on running volume and running intensity and the development of injuries show conflicting results. This may be related to previously applied study designs, methods used to quantify the performed running and the statistical analysis of the collected data. The aim of the Run Clever trial is to investigate if a focus on running intensity compared with a focus on running volume in a running schedule influences the overall injury risk differently. The Run Clever trial is a randomized trial with a 24-week follow-up. Healthy recreational runners between 18 and 65 years and with an average of 1-3 running sessions per week the past 6 months are included. Participants are randomized into two intervention groups: Running schedule-I and Schedule-V. Schedule-I emphasizes a progression in running intensity by increasing the weekly volume of running at a hard pace, while Schedule-V emphasizes a progression in running volume, by increasing the weekly overall volume. Data on the running performed is collected by GPS. Participants who sustain running-related injuries are diagnosed by a diagnostic team of physiotherapists using standardized diagnostic criteria. The members of the diagnostic team are blinded. The study design, procedures and informed consent were approved by the Ethics Committee Northern Denmark Region (N-20140069). The Run Clever trial will provide insight into possible differences in injury risk between running schedules emphasizing either running intensity or running volume. The risk of sustaining volume- and intensity-related injuries will be compared in the two intervention groups using a competing

  3. The study of the volume and 1H MRS of the hippocampus in posttraumatic stress disorder

    International Nuclear Information System (INIS)

    Yang Bo; Zhou Yicheng; Xia Jun; Xia Liming; Wang Chengyuan

    2006-01-01

    Objective: To study the changes of the hippocampus metabolites and the hippoeampus volume with MRI, and to explore the posibble pathophysiology of the hippocampus injure in posttraumatic stress disorder(PTSD). Methods: Seventeen cases of PTSD and 17 age-matched normal subjects (control subjects) were examined on a clinical 1.5 T MRI/MRS system. Proton multi-voxel spectroscopy imaging ( 1 H-MRSI) was obtained from two sides of the hippocampus region. The metabolites included N-acetylaspartate (NAA), creatine and phosphocreatine (Cr), and choline-containing compounds (Cho). The values of NAA, Cr, and Cho were calculated by integration of their peaks. The volume of the hippocampus of the two sides and the brain volume were measured with volume analysis software, and the resulting data were normalized according to the individual brain volume. Both the value of the metabolites and volume of the hippocampus were compared between the two groups respectively. Results: The volumes of left and right hippocampus were (2130±221 )mm 3 and (2571±190) mm 3 in PTSD cases, and they were (2382±157) mm 3 and (2572±186) mm 3 in the control subjects. The volume of left hippocampus of PTSD was smaller than that of the control subjects (P 0.05). NAA and Cr was significantly reduced in PTSD (Left: NAA= 2.8±0.7, Cr=2.3±0.6; Right: NAA 2.9±0.9, Cr=2.3±0.7) bilaterally when compared with those of control subjects (Left: NAA=3.8±0.8, Cr=2.7±0.5; Right: NAA=3.9±0.8, Cr=2.8±0.5) (P 0.05). Conclusion: The results of this study add support to the view that the hippocampus may participate in the pathophysiology of PTSD, and the findings of volume and metabolite changes in the hippocampus has great value in diagnosing PTSD and in exploring the posibble pathophysiology mechanisms of hippocampus injure in PTSD. (authors)

  4. Lower Flathead System Fisheries Study, Executive Summary, Volume I, 1983-1987 Final Report.

    Energy Technology Data Exchange (ETDEWEB)

    Cross, David; DosSantos, Joseph M.

    1988-06-01

    This Executive Summary, Volume I, of the lower Flathead System Fisheries Study Final Report, was prepared to provide a study overview for persons who are not fisheries scientists. The contents provide an introduction to the study and its objectives, a short description of the study area, a discussion of the major findings and conclusions of the study, and the description of fisheries management alternatives available to managers of the lower Flathead system. Technical reports were prepared for those portions of the study dealing with the lower Flathead River and its tributaries, Volume II, and the South Bay of Flathead Lake, Volume III. The annual hydrographic regime of the Flathead system, consisting of upper rivers, lake and lower river, has been modified by the construction and operation of two major hydroelectric facilities, Hungry Horse Dam on the south fork Flathead River and Kerr Dam at the outlet of Flathead Lake. The modified hydrographic regime has resulted in significant impacts to kokanee (Oncorhynchus nerka) and several species of trout. Kerr Dam, closed in 1938, controls Flathead Lake levels between 878.7 m (2883 ft) and 881.8 m (2893 ft) and discharges into the lower Flathead River. Kerr Dam is a 63.4 m (208 ft) high concrete arch structure located 7.2 km (4.5 miles) downstream from the outlet of Flathead Lake. The facility is used by Montana Power Company primarily for system frequency load control with some use for low level base load. 77 refs., 5 figs.

  5. The Value of Children: A Cross-National Study, Volume Two. Philippines.

    Science.gov (United States)

    Bulatao, Rodolfo A.

    This volume, second in a series of seven reports of the Value of Children Project, discusses results of the survey in the Philippines. The study identifies major values and disvalues that Filipino parents attach to children. It also examines characteristics of parents that are related to values and disvalues. The document is presented in seven…

  6. Los Alamos Controlled Air Incinerator for radioactive waste. Volume II. Engineering design reference manual

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, R.A.; Draper, W.E.; Newmyer, J.M.; Warner, C.L.

    1982-10-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawings, specifications, calculations, and costs. It aids duplication of the process at other facilities.

  7. Los Alamos Controlled Air Incinerator for radioactive waste. Volume II. Engineering design reference manual

    International Nuclear Information System (INIS)

    Koenig, R.A.; Draper, W.E.; Newmyer, J.M.; Warner, C.L.

    1982-10-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawings, specifications, calculations, and costs. It aids duplication of the process at other facilities

  8. Reports on research achievements in developing high-performance industrial furnaces in fiscal 1998 (Research and development of high-performance industrial furnaces). Volume 1; 1998 nendo koseino kogyoro nado ni kansuru kenkyu kaihatsu seika hokokusho. 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    From the reports on research achievements in developing high-performance industrial furnaces in fiscal 1998, the report volume 1 was prepared as a research achievement report of each working group, detailing fundamental researches, heating furnaces, and heat treatment furnaces. The fundamental researches have researched combustion evaluating technology, characteristics of the area in the vicinity of a combustor, characteristics of combustion of high-temperature air, heating characteristics of a furnace to investigate effect of local heat absorption, and combustion evaluation. For the heating furnaces, the following subjects were studied: development of an in-furnace combustion model, summary of an experiment for evaluating high-temperature air combustion, furnace height relative to combustion heat transfer characteristics, heat loss minimizing technology, combustion heat transfer characteristics of liquid fuels, optimal operation of the high-temperature air combustion, basic control in heating control, and steel piece heating control. Studies were performed for the heat treatment furnaces on the case of a direct firing furnace in evaluating the heat transfer characteristics, the case of a radiant tube furnace, application of thermal fluid simulation technology, furnace averaging technology, soot reducing technology, control technology, and trial design on a high-performance heat treatment furnace. (NEDO)

  9. On the volume of cremated remains

    DEFF Research Database (Denmark)

    Harvig, Lise Lock; Lynnerup, Niels

    2013-01-01

    Harvig, L., Lynnerup, N. 2013. On the effective volume of prehistoric cremains - a comparative study of cremated bone volume measured manually and assessed by Computed Tomography. Journal of Archaeological Science 40, p. 2713–2722.......Harvig, L., Lynnerup, N. 2013. On the effective volume of prehistoric cremains - a comparative study of cremated bone volume measured manually and assessed by Computed Tomography. Journal of Archaeological Science 40, p. 2713–2722....

  10. A Comparative Study of Pituitary Volume Variations in MRI in Acute Onset of Psychiatric Conditions.

    Science.gov (United States)

    Soni, Brijesh Kumar; Joish, Upendra Kumar; Sahni, Hirdesh; George, Raju A; Sivasankar, Rajeev; Aggarwal, Rohit

    2017-02-01

    The growing belief that endocrine abnormalities may underlie many mental conditions has led to increased use of imaging and hormonal assays in patients attending to psychiatric OPDs. People who are in an acute phase of a psychiatric disorder show Hypothalamic Pituitary Adrenal (HPA) axis hyperactivity, but the precise underlying central mechanisms are unclear. To assess the pituitary gland volume variations in patients presenting with new onset acute psychiatric illness in comparison with age and gender matched controls by using MRI. The study included 50 patients, with symptoms of acute psychiatric illness presenting within one month of onset of illness and 50 age and gender matched healthy controls. Both patients and controls were made to undergo MRI of the Brain. A 0.9 mm slices of entire brain were obtained by 3 dimensional T1 weighted sequence. Pituitary gland was traced in all sagittal slices. Anterior pituitary and posterior pituitary bright spot were measured separately in each slice. Volume of the pituitary (in cubic centimetre- cm 3 ) was calculated by summing areas. Significance of variations in pituitary gland volumes was compared between the cases and controls using Analysis of Covariance (ANOVA). There were significantly larger pituitary gland volumes in the cases than the controls, irrespective of psychiatric diagnosis (ANOVA, f=15.56; p=0.0002). Pituitary volumes in cases were 15.36% (0.73 cm 3 ) higher than in controls. There is a strong likelihood of HPA axis overactivity during initial phase of all mental disorders along with increased pituitary gland volumes. Further studies including hormonal assays and correlation with imaging are likely to provide further insight into neuroanatomical and pathological basis of psychiatric disorders.

  11. Nuclear legislation. Analytical study. Regulatory and Institutional framework for nuclear activities in OECD Member countries. Volume I

    International Nuclear Information System (INIS)

    1983-01-01

    This study is part of a series of analytical studies of the major aspects of nuclear legislation in OECD Member countries and is published in two volumes. This Volume I of the study is a revision and an expansion of a 1969 study concerning the organisation and general regime governing nuclear activities. The national studies were prepared, to the extent possible, following a standard plan for all countries to facilitate information retrieval and comparison. (NEA) [fr

  12. Safety and efficacy of bariatric surgery in Mexico: A detailed analysis of 500 surgeries performed at a high-volume center.

    Science.gov (United States)

    Guilbert, L; Joo, P; Ortiz, C; Sepúlveda, E; Alabi, F; León, A; Piña, T; Zerrweck, C

    2018-06-19

    Bariatric surgery is the best method for treating obesity and its comorbidities. Our aim was to provide a detailed analysis of the perioperative outcomes in Mexican patients that underwent surgery at a high-volume hospital center. A retrospective study was conducted on all the patients that underwent bariatric surgery at a single hospital center within a time frame of 4 and one-half years. Demographics, the perioperative variables, complications (early and late), weight loss, failure, and type 2 diabetes mellitus remission were all analyzed. Five hundred patients were included in the study, 83.2% of whom were women. Mean patient age was 38.8 years and BMI was 44.1kg/m 2 . The most common comorbidities were high blood pressure, dyslipidemia, and diabetes. Laparoscopic gastric bypass surgery was performed in 85.8% of the patients, sleeve gastrectomy in 13%, and revision surgeries in 1%. There were 9.8% early complications and 12.2% late ones, with no deaths. Overall weight loss as the excess weight loss percentage at 12 and 24 months was 76.9 and 77.6%. The greatest weight loss at 12 months was seen in the patients that underwent laparoscopic gastric bypass. A total of 11.4% of the patients had treatment failure. In the patients with type 2 diabetes mellitus, 68.7% presented with complete disease remission and 9.3% with partial remission. There was improvement in 21.8% of the cases. In our experience at a high-volume hospital center, bariatric surgery is safe and effective, based on the low number of adverse effects and consequent weight loss and type 2 diabetes mellitus control. Long-term studies with a larger number of patients are needed to determine the final impact of those procedures. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  13. Long-Term Prediction of Emergency Department Revenue and Visitor Volume Using Autoregressive Integrated Moving Average Model

    Directory of Open Access Journals (Sweden)

    Chieh-Fan Chen

    2011-01-01

    Full Text Available This study analyzed meteorological, clinical and economic factors in terms of their effects on monthly ED revenue and visitor volume. Monthly data from January 1, 2005 to September 30, 2009 were analyzed. Spearman correlation and cross-correlation analyses were performed to identify the correlation between each independent variable, ED revenue, and visitor volume. Autoregressive integrated moving average (ARIMA model was used to quantify the relationship between each independent variable, ED revenue, and visitor volume. The accuracies were evaluated by comparing model forecasts to actual values with mean absolute percentage of error. Sensitivity of prediction errors to model training time was also evaluated. The ARIMA models indicated that mean maximum temperature, relative humidity, rainfall, non-trauma, and trauma visits may correlate positively with ED revenue, but mean minimum temperature may correlate negatively with ED revenue. Moreover, mean minimum temperature and stock market index fluctuation may correlate positively with trauma visitor volume. Mean maximum temperature, relative humidity and stock market index fluctuation may correlate positively with non-trauma visitor volume. Mean maximum temperature and relative humidity may correlate positively with pediatric visitor volume, but mean minimum temperature may correlate negatively with pediatric visitor volume. The model also performed well in forecasting revenue and visitor volume.

  14. Association Between Provider Volume and Comorbidity on Hospital Utilization and Outcomes of Total Hip Arthroplasty Among National Health Insurance Enrollees

    Directory of Open Access Journals (Sweden)

    Chung-Shih Huang

    2011-06-01

    Conclusions: This study revealed that the volume of THAs performed by individual surgeons was a more important determinant of hospital utilization than hospital volume. Perioperative adverse events were associated with patients' age and comorbidity.

  15. Effect of hospital volume on processes of breast cancer care: A National Cancer Data Base study.

    Science.gov (United States)

    Yen, Tina W F; Pezzin, Liliana E; Li, Jianing; Sparapani, Rodney; Laud, Purushuttom W; Nattinger, Ann B

    2017-05-15

    The purpose of this study was to examine variations in delivery of several breast cancer processes of care that are correlated with lower mortality and disease recurrence, and to determine the extent to which hospital volume explains this variation. Women who were diagnosed with stage I-III unilateral breast cancer between 2007 and 2011 were identified within the National Cancer Data Base. Multiple logistic regression models were developed to determine whether hospital volume was independently associated with each of 10 individual process of care measures addressing diagnosis and treatment, and 2 composite measures assessing appropriateness of systemic treatment (chemotherapy and hormonal therapy) and locoregional treatment (margin status and radiation therapy). Among 573,571 women treated at 1755 different hospitals, 38%, 51%, and 10% were treated at high-, medium-, and low-volume hospitals, respectively. On multivariate analysis controlling for patient sociodemographic characteristics, treatment year and geographic location, hospital volume was a significant predictor for cancer diagnosis by initial biopsy (medium volume: odds ratio [OR] = 1.15, 95% confidence interval [CI] = 1.05-1.25; high volume: OR = 1.30, 95% CI = 1.14-1.49), negative surgical margins (medium volume: OR = 1.15, 95% CI = 1.06-1.24; high volume: OR = 1.28, 95% CI = 1.13-1.44), and appropriate locoregional treatment (medium volume: OR = 1.12, 95% CI = 1.07-1.17; high volume: OR = 1.16, 95% CI = 1.09-1.24). Diagnosis of breast cancer before initial surgery, negative surgical margins and appropriate use of radiation therapy may partially explain the volume-survival relationship. Dissemination of these processes of care to a broader group of hospitals could potentially improve the overall quality of care and outcomes of breast cancer survivors. Cancer 2017;123:957-66. © 2016 American Cancer Society. © 2016 American Cancer Society.

  16. Relative strengths of the calf muscles based on MRI volume measurements.

    Science.gov (United States)

    Jeng, Clifford L; Thawait, Gaurav K; Kwon, John Y; Machado, Antonio; Boyle, James W; Campbell, John; Carrino, John A

    2012-05-01

    In 1985, Silver et al. published a cadaver study which determined the relative order of strength of the muscles in the calf. Muscle strength, which is proportional to volume, was obtained by dissecting out the individual muscles, weighing them, and then multiplying by the specific gravity. No similar studies have been performed using {\\it in vivo} measurements of muscle volume. Ten normal subjects underwent 3-Tesla MRI's of both lower extremities using non-fat-saturated T2 SPACE sequences. The volume for each muscle was determined by tracing the muscle contour on sequential axial images and then interpolating the volume using imaging software. The results from this study differ from Silver's original article. The lateral head of the gastrocnemius was found to be stronger than the tibialis anterior muscle. The FHL and EDL muscles were both stronger than the peroneus longus. There was no significant difference in strength between the peroneus longus and brevis muscles. This revised order of muscle strengths in the calf based on in vivo MRI findings may assist surgeons in determining the optimal tendons to transfer in order to address muscle weakness and deformity.

  17. Assessing brain volume changes in older women with breast cancer receiving adjuvant chemotherapy: a brain magnetic resonance imaging pilot study.

    Science.gov (United States)

    Chen, Bihong T; Sethi, Sean K; Jin, Taihao; Patel, Sunita K; Ye, Ningrong; Sun, Can-Lan; Rockne, Russell C; Haacke, E Mark; Root, James C; Saykin, Andrew J; Ahles, Tim A; Holodny, Andrei I; Prakash, Neal; Mortimer, Joanne; Waisman, James; Yuan, Yuan; Somlo, George; Li, Daneng; Yang, Richard; Tan, Heidi; Katheria, Vani; Morrison, Rachel; Hurria, Arti

    2018-05-02

    Cognitive decline is among the most feared treatment-related outcomes of older adults with cancer. The majority of older patients with breast cancer self-report cognitive problems during and after chemotherapy. Prior neuroimaging research has been performed mostly in younger patients with cancer. The purpose of this study was to evaluate longitudinal changes in brain volumes and cognition in older women with breast cancer receiving adjuvant chemotherapy. Women aged ≥ 60 years with stage I-III breast cancer receiving adjuvant chemotherapy and age-matched and sex-matched healthy controls were enrolled. All participants underwent neuropsychological testing with the US National Institutes of Health (NIH) Toolbox for Cognition and brain magnetic resonance imaging (MRI) prior to chemotherapy, and again around one month after the last infusion of chemotherapy. Brain volumes were measured using Neuroreader™ software. Longitudinal changes in brain volumes and neuropsychological scores were analyzed utilizing linear mixed models. A total of 16 patients with breast cancer (mean age 67.0, SD 5.39 years) and 14 age-matched and sex-matched healthy controls (mean age 67.8, SD 5.24 years) were included: 7 patients received docetaxel and cyclophosphamide (TC) and 9 received chemotherapy regimens other than TC (non-TC). There were no significant differences in segmented brain volumes between the healthy control group and the chemotherapy group pre-chemotherapy (p > 0.05). Exploratory hypothesis generating analyses focusing on the effect of the chemotherapy regimen demonstrated that the TC group had greater volume reduction in the temporal lobe (change = - 0.26) compared to the non-TC group (change = 0.04, p for interaction = 0.02) and healthy controls (change = 0.08, p for interaction = 0.004). Similarly, the TC group had a decrease in oral reading recognition scores (change = - 6.94) compared to the non-TC group (change = - 1.21, p for

  18. Volume calculations of coarse woody debris; evaluation of coarse woody debris volume calculations and consequences for coarse woody debris volume estimates in forest reserves

    NARCIS (Netherlands)

    Wijdeven, S.M.J.; Vaessen, O.H.B.; Hees, van A.F.M.; Olsthoorn, A.F.M.

    2005-01-01

    Dead wood is recognized as one of the key indicators for sustainable forest management and biodiversity. Accurate assessments of dead wood volume are thus necessary. In this study New volume models were designed based on actual volume measurements of coarse woody debris. The New generic model

  19. A Quantitative Analysis of the Relationship between Medicare Payment and Service Volume for Glaucoma Procedures from 2005 through 2009.

    Science.gov (United States)

    Gong, Dan; Jun, Lin; Tsai, James C

    2015-05-01

    To calculate the association between Medicare payment and service volume for 6 commonly performed glaucoma procedures. Retrospective, longitudinal database study. A 100% dataset of all glaucoma procedures performed on Medicare Part B beneficiaries within the United States from 2005 to 2009. Fixed-effects regression model using Medicare Part B carrier data for all 50 states and the District of Columbia, controlling for time-invariant carrier-specific characteristics, national trends in glaucoma service volume, Medicare beneficiary population, number of ophthalmologists, and income per capita. Payment-volume elasticities, defined as the percent change in service volume per 1% change in Medicare payment, for laser trabeculoplasty (Current Procedural Terminology [CPT] code 65855), trabeculectomy without previous surgery (CPT code 66170), trabeculectomy with previous surgery (CPT code 66172), aqueous shunt to reservoir (CPT code 66180), laser iridotomy (CPT code 66761), and scleral reinforcement with graft (CPT code 67255). The payment-volume elasticity was nonsignificant for 4 of 6 procedures studied: laser trabeculoplasty (elasticity, -0.27; 95% confidence interval [CI], -1.31 to 0.77; P = 0.61), trabeculectomy without previous surgery (elasticity, -0.42; 95% CI, -0.85 to 0.01; P = 0.053), trabeculectomy with previous surgery (elasticity, -0.28; 95% CI, -0.83 to 0.28; P = 0.32), and aqueous shunt to reservoir (elasticity, -0.47; 95% CI, -3.32 to 2.37; P = 0.74). Two procedures yielded significant associations between Medicare payment and service volume. For laser iridotomy, the payment-volume elasticity was -1.06 (95% CI, -1.39 to -0.72; P payment, laser iridotomy service volume increased by 1.06%. For scleral reinforcement with graft, the payment-volume elasticity was -2.92 (95% CI, -5.72 to -0.12; P = 0.041): for every 1% decrease in CPT code 67255 payment, scleral reinforcement with graft service volume increased by 2.92%. This study calculated the association

  20. Does Flywheel Paradigm Training Improve Muscle Volume and Force? A Meta-Analysis.

    Science.gov (United States)

    Nuñez Sanchez, Francisco J; Sáez de Villarreal, Eduardo

    2017-11-01

    Núñez Sanchez, FJ and Sáez de Villarreal, E. Does flywheel paradigm training improve muscle volume and force? A meta-analysis. J Strength Cond Res 31(11): 3177-3186, 2017-Several studies have confirmed the efficacy of flywheel paradigm training for improving or benefiting muscle volume and force. A meta-analysis of 13 studies with a total of 18 effect sizes was performed to analyse the role of various factors on the effectiveness of flywheel paradigm training. The following inclusion criteria were employed for the analysis: (a) randomized studies; (b) high validity and reliability instruments; (c) published in a high quality peer-reviewed journal; (d) healthy participants; (e) studies where the eccentric programme were described; and (f) studies where increases in muscle volume and force were measured before and after training. Increases in muscle volume and force were noted through the use of flywheel systems during short periods of training. The increase in muscle mass appears was not influenced by the existence of eccentric overload during the exercise. The increase in force was significantly higher with the existence of eccentric overload during the exercise. The responses identified in this analysis are essential and should be considered by strength and conditioning professionals regarding the most appropriate dose response trends for flywheel paradigm systems to optimize the increase in muscle volume and force.

  1. Effect of hydration status on atrial and ventricular volumes and function in healthy adult volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Schantz, Daryl I. [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); University of Manitoba, Variety Children' s Heart Centre, Winnipeg, MB (Canada); Dragulescu, Andreea [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); Memauri, Brett [University of Manitoba, Department of Radiology, St. Boniface General Hospital, Winnipeg, MB (Canada); Grotenhuis, Heynric B. [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); Wilhelmina Children' s Hospital, Utrecht (Netherlands); Seed, Mike; Grosse-Wortmann, Lars [The Hospital for Sick Children, The Labatt Family Heart Centre in the Department of Paediatrics, Toronto, ON (Canada); The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto, ON (Canada)

    2016-10-15

    Assessment of cardiac chamber volumes is a fundamental part of cardiac magnetic resonance (CMR) imaging. While the effects of inter- and intraobserver variability have been studied and have a recognized effect on the comparability of serial cardiac MR imaging studies, the effect of differences in hydration status has not been evaluated. To evaluate the effects of volume administration on cardiac chamber volumes. Thirteen healthy adults underwent a baseline cardiac MR to evaluate cardiac chamber volumes after an overnight fast. They were then given two saline boluses of 10 ml/kg of body weight and the cardiac MR was repeated immediately after each bolus. From the baseline scan to the final scan there was a significant increase in all four cardiac chamber end-diastolic volumes. Right atrial volumes increased 8.0%, from 61.1 to 66.0 ml/m2 (P<0.001), and left atrial volumes increased 10.0%, from 50.0 to 55.0 ml/m2 (P<0.001). Right ventricular volumes increased 6.0%, from 91.1 to 96.5 ml/m2 (P<0.001), and left ventricular volumes increased 3.2%, from 87.0 to 89.8 ml/m2 (P<0.001). Hydration status has a significant effect on the end-diastolic volumes of all cardiac chambers assessed by cardiac MR. Thus, hydration represents a ''variable'' that should be taken into account when assessing cardiac chamber volumes, especially when performing serial imaging studies in a patient. (orig.)

  2. Effect of hydration status on atrial and ventricular volumes and function in healthy adult volunteers

    International Nuclear Information System (INIS)

    Schantz, Daryl I.; Dragulescu, Andreea; Memauri, Brett; Grotenhuis, Heynric B.; Seed, Mike; Grosse-Wortmann, Lars

    2016-01-01

    Assessment of cardiac chamber volumes is a fundamental part of cardiac magnetic resonance (CMR) imaging. While the effects of inter- and intraobserver variability have been studied and have a recognized effect on the comparability of serial cardiac MR imaging studies, the effect of differences in hydration status has not been evaluated. To evaluate the effects of volume administration on cardiac chamber volumes. Thirteen healthy adults underwent a baseline cardiac MR to evaluate cardiac chamber volumes after an overnight fast. They were then given two saline boluses of 10 ml/kg of body weight and the cardiac MR was repeated immediately after each bolus. From the baseline scan to the final scan there was a significant increase in all four cardiac chamber end-diastolic volumes. Right atrial volumes increased 8.0%, from 61.1 to 66.0 ml/m2 (P<0.001), and left atrial volumes increased 10.0%, from 50.0 to 55.0 ml/m2 (P<0.001). Right ventricular volumes increased 6.0%, from 91.1 to 96.5 ml/m2 (P<0.001), and left ventricular volumes increased 3.2%, from 87.0 to 89.8 ml/m2 (P<0.001). Hydration status has a significant effect on the end-diastolic volumes of all cardiac chambers assessed by cardiac MR. Thus, hydration represents a ''variable'' that should be taken into account when assessing cardiac chamber volumes, especially when performing serial imaging studies in a patient. (orig.)

  3. Volume-monitored chest CT: a simplified method for obtaining motion-free images near full inspiratory and end expiratory lung volumes

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Kathryn S. [The Ohio State University College of Medicine, Columbus, OH (United States); Long, Frederick R. [Nationwide Children' s Hospital, The Children' s Radiological Institute, Columbus, OH (United States); Flucke, Robert L. [Nationwide Children' s Hospital, Department of Pulmonary Medicine, Columbus, OH (United States); Castile, Robert G. [The Research Institute at Nationwide Children' s Hospital, Center for Perinatal Research, Columbus, OH (United States)

    2010-10-15

    Lung inflation and respiratory motion during chest CT affect diagnostic accuracy and reproducibility. To describe a simple volume-monitored (VM) method for performing reproducible, motion-free full inspiratory and end expiratory chest CT examinations in children. Fifty-two children with cystic fibrosis (mean age 8.8 {+-} 2.2 years) underwent pulmonary function tests and inspiratory and expiratory VM-CT scans (1.25-mm slices, 80-120 kVp, 16-40 mAs) according to an IRB-approved protocol. The VM-CT technique utilizes instruction from a respiratory therapist, a portable spirometer and real-time documentation of lung volume on a computer. CT image quality was evaluated for achievement of targeted lung-volume levels and for respiratory motion. Children achieved 95% of vital capacity during full inspiratory imaging. For end expiratory scans, 92% were at or below the child's end expiratory level. Two expiratory exams were judged to be at suboptimal volumes. Two inspiratory (4%) and three expiratory (6%) exams showed respiratory motion. Overall, 94% of scans were performed at optimal volumes without respiratory motion. The VM-CT technique is a simple, feasible method in children as young as 4 years to achieve reproducible high-quality full inspiratory and end expiratory lung CT images. (orig.)

  4. Lung volumes during sustained microgravity on Spacelab SLS-1

    Science.gov (United States)

    Elliott, Ann R.; Prisk, Gordon Kim; Guy, Harold J. B.; West, John B.

    1994-01-01

    Gravity is known to influence the topographical gradients of pulmonary ventilation, perfusion, and pleural pressures. The effect of sustained microgravity on lung volumes has not previously been investigated. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box and flowmeter system and a respiratory mass spectrometer. Measurements of tidal volume (V(sub T)), expiratory reserve volume (ERV), inspiratory and expiratory vital capacities (IVC, EVC), functional residual capacity (FRC), and residual volume (RV) were made. During microgravity, V(sub T) decreased by 15%. IVC and EVC were slightly reduced during the first 24 hrs of microgravity and returned to 1 g standing values within 72 hrs after the onset of microgravity. FRC was reduced by 15% and ERV decreased by 10-20%. RV was significantly reduced by 18%. The reductions in FRC, ERV, and V(sub T) during microgravity are probably due to the cranial shift of the diaphragm and an increase in intrathoracic blood volume.

  5. Evidence for the changes of pituitary volumes in patients with post-traumatic stress disorder.

    Science.gov (United States)

    Atmaca, Murad; Ozer, Omer; Korkmaz, Sevda; Taskent, Ismail; Yildirim, Hanefi

    2017-02-28

    In pubertal and postpubertal patients with post-traumatic stress disorder (PTSD), significantly greater pituitary gland volumes have been reported. Moving from this point, in the present study, we aimed to investigate pituitary gland volumes in patients with PTSD and hypothesized that volumes of the gland would be structurally changed. Volumetric magnetic resonance imaging of the pituitary gland was performed among sixteen patients with PTSD and fifteen healthy control subjects. We found that the mean volume of the pituitary gland was statistically significant and smaller than that of healthy subjects (0.69±0.08cm 3 for patient group and 0.83±0.21 for control subjects). Consequently, in the present study, we found that patients with PTSD had smaller pituitary gland volumes than those of healthy controls like other anxiety disorders. It is important to provide support for this finding in future longitudinal investigations. Copyright © 2016. Published by Elsevier B.V.

  6. Meditation and yoga practice are associated with smaller right amygdala volume: the Rotterdam study

    NARCIS (Netherlands)

    R.A. Gotink (Rinske); M.W. Vernooij (Meike); M.K. Ikram (Kamran); W.J. Niessen (Wiro); Krestin, G.P. (Gabriel P.); A. Hofman (Albert); H.W. Tiemeier (Henning); M.G.M. Hunink (Myriam)

    2018-01-01

    textabstractTo determine the association between meditation and yoga practice, experienced stress, and amygdala and hippocampal volume in a large population-based study. This study was embedded within the population-based Rotterdam Study and included 3742 participants for cross-sectional

  7. Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yingru; Vliegenthart, Rozemarijn; Wang, Ying; Ooijen, Peter M.A. van; Oudkerk, Matthijs [University of Groningen/University Medical Center Groningen, Center for Medical Imaging - North East Netherlands, Department of Radiology, P.O. Box 30.001, Groningen (Netherlands); Bock, Geertruida H. de [University of Groningen/University Medical Center Groningen, Department of Epidemiology, P.O. Box 30.001, Groningen (Netherlands); Klaveren, Rob J. van [Lievensberg Hospital, Department of Pulmonology, P.O. Box 135, Bergen op Zoom (Netherlands); Bogoni, Luca [CAD Group, Siemens Medical Solutions USA, Inc., Malvern, PA (United States); Jong, Pim A. de; Mali, Willem P. [University of Utrecht, Department of Radiology, University Medical Center Utrecht, P.O. Box 85500, Utrecht (Netherlands)

    2012-10-15

    To evaluate performance of computer-aided detection (CAD) beyond double reading for pulmonary nodules on low-dose computed tomography (CT) by nodule volume. A total of 400 low-dose chest CT examinations were randomly selected from the NELSON lung cancer screening trial. CTs were evaluated by two independent readers and processed by CAD. A total of 1,667 findings marked by readers and/or CAD were evaluated by a consensus panel of expert chest radiologists. Performance was evaluated by calculating sensitivity of pulmonary nodule detection and number of false positives, by nodule characteristics and volume. According to the screening protocol, 90.9 % of the findings could be excluded from further evaluation, 49.2 % being small nodules (less than 50 mm{sup 3}). Excluding small nodules reduced false-positive detections by CAD from 3.7 to 1.9 per examination. Of 151 findings that needed further evaluation, 33 (21.9 %) were detected by CAD only, one of them being diagnosed as lung cancer the following year. The sensitivity of nodule detection was 78.1 % for double reading and 96.7 % for CAD. A total of 69.7 % of nodules undetected by readers were attached nodules of which 78.3 % were vessel-attached. CAD is valuable in lung cancer screening to improve sensitivity of pulmonary nodule detection beyond double reading, at a low false-positive rate when excluding small nodules. circle Computer-aided detection (CAD) has known advantages for computed tomography (CT). (orig.)

  8. Performance of computer-aided detection of pulmonary nodules in low-dose CT: comparison with double reading by nodule volume

    International Nuclear Information System (INIS)

    Zhao, Yingru; Vliegenthart, Rozemarijn; Wang, Ying; Ooijen, Peter M.A. van; Oudkerk, Matthijs; Bock, Geertruida H. de; Klaveren, Rob J. van; Bogoni, Luca; Jong, Pim A. de; Mali, Willem P.

    2012-01-01

    To evaluate performance of computer-aided detection (CAD) beyond double reading for pulmonary nodules on low-dose computed tomography (CT) by nodule volume. A total of 400 low-dose chest CT examinations were randomly selected from the NELSON lung cancer screening trial. CTs were evaluated by two independent readers and processed by CAD. A total of 1,667 findings marked by readers and/or CAD were evaluated by a consensus panel of expert chest radiologists. Performance was evaluated by calculating sensitivity of pulmonary nodule detection and number of false positives, by nodule characteristics and volume. According to the screening protocol, 90.9 % of the findings could be excluded from further evaluation, 49.2 % being small nodules (less than 50 mm 3 ). Excluding small nodules reduced false-positive detections by CAD from 3.7 to 1.9 per examination. Of 151 findings that needed further evaluation, 33 (21.9 %) were detected by CAD only, one of them being diagnosed as lung cancer the following year. The sensitivity of nodule detection was 78.1 % for double reading and 96.7 % for CAD. A total of 69.7 % of nodules undetected by readers were attached nodules of which 78.3 % were vessel-attached. CAD is valuable in lung cancer screening to improve sensitivity of pulmonary nodule detection beyond double reading, at a low false-positive rate when excluding small nodules. circle Computer-aided detection (CAD) has known advantages for computed tomography (CT). (orig.)

  9. The relationship between patient volume and mortality in American trauma centres: a systematic review of the evidence.

    Science.gov (United States)

    Caputo, Lisa M; Salottolo, Kristin M; Slone, Denetta Sue; Mains, Charles W; Bar-Or, David

    2014-03-01

    To synthesise published and unpublished findings examining the relationship between institutional trauma centre volume or trauma patient volume per surgeon and mortality. Evidence on the relationship between patient volume and survival in trauma patients is inconclusive in the literature and remains controversial. A literature search was performed to identify studies published between 1976 and 2013 via MEDLINE (Pubmed) and the Cumulative Index to Nursing and Allied Health Literature (EbscoHost) as well as footnote chasing. Abstracts from appropriate conferences and ProQuest Dissertations and Theses were also searched. Inclusion criteria required studies to be original research published in English that examined the relationship between mortality and either institutional or per surgeon volume in American trauma centres. We employed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Statement checklist and flowchart. The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach was employed to rate the quality of the evidence. Of 1392 studies reviewed, 19 studies met defined inclusion criteria; all studies were retrospective. The definition of volume was heterogeneous across the studies. Patient population and analysis methods also varied across the studies. Sixteen studies (84%) examined the relationship between institutional trauma centre volume and mortality. Of the 16 studies, 12 examined the volume of severely injured patients and eight examined overall trauma patient volume. High institutional volume was associated with at least somewhat improved mortality in ten of 16 studies (63%); however, nearly half of these studies found only some subpopulations experienced benefits. In the remaining six studies, volume was not associated with any benefits. Four studies (25%) analysed the impact of surgeon volume on mortality. High volume per surgeon was associated with improved mortality in only one of four studies

  10. [Lung volume reduction surgery for severe pulmonary emphysema in Iceland].

    Science.gov (United States)

    Gunnarsson, Sverrir I; Johannsson, Kristinn B; Guðjónsdóttir, Marta; Jónsson, Steinn; Beck, Hans J; Magnusson, Bjorn; Gudbjartsson, Tomas

    2011-12-01

    Lung volume reduction surgery (LVRS) can benefit patients with severe emphysema. The aim of this study was to evaluate the outcome of LVRS performed in Iceland. A prospective study of 16 consecutive patients who underwent bilateral LVRS through median sternotomy between January 1996 and December 2008. All patients had disabling dyspnea, lung hyperinflation, and emphysema with upper lobe predominance. Preoperatively all patients underwent pulmonary rehabilitation. Spirometry, lung volumes, arterial blood gases and exercise capacity were measured before and after surgery. Mean follow-up time was 8.7 years. Mean age was 59.2 ± 5.9 years. All patients had a history of heavy smoking. There was no perioperative mortality and survival was 100%, 93%, and 63% at 1, 5, and 10 years, respectively. The forced expiratory volume in 1 second (FEV1) and the forced vital capacity (FVC) improved significantly after surgery by 35% (plung capacity, residual volume and partial pressure of CO2 also showed statistically significant improvements but exercise capacity, O2 consumption and diffusing capacity of the lung for CO did not change. Prolonged air leak (≥ 7 days) was the most common complication (n=7). Five patients required reoperation, most commonly for sternal dehiscence (n=4). In this small prospective study, FEV1 and FVC increased and lung volumes and PaCO2 improved after LVRS. Long term survival was satisfactory although complications such as reoperations for sternal dehiscence were common and hospital stay therefore often prolonged.

  11. Evaluation of a cumulative SUV-volume histogram method for parameterizing heterogeneous intratumoural FDG uptake in non-small cell lung cancer PET studies

    Energy Technology Data Exchange (ETDEWEB)

    Velden, Floris H.P. van; Cheebsumon, Patsuree; Yaqub, Maqsood; Hoekstra, Otto S.; Lammertsma, Adriaan A.; Boellaard, Ronald [VU University Medical Center, Department of Nuclear Medicine and PET Research, PO Box 7057, Amsterdam (Netherlands); Smit, Egbert F. [VU University Medical Center, Department of Pulmonary Diseases, Amsterdam (Netherlands)

    2011-09-15

    Standardized uptake values (SUV) are commonly used for quantification of whole-body [{sup 18}F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) studies. Changes in SUV following therapy, however, only provide a proper measure of response in case of homogeneous FDG uptake in the tumour. The purpose of this study was therefore to implement and characterize a method that enables quantification of heterogeneity in tumour FDG uptake. Cumulative SUV-volume histograms (CSH), describing % of total tumour volume above % threshold of maximum SUV (SUV{sub max}), were calculated. The area under a CSH curve (AUC) is a quantitative index of tumour uptake heterogeneity, with lower AUC corresponding to higher degrees of heterogeneity. Simulations of homogeneous and heterogeneous responses were performed to assess the value of AUC-CSH for measuring uptake and/or response heterogeneity. In addition, partial volume correction and image denoising was applied prior to calculating AUC-CSH. Finally, the method was applied to a number of human FDG scans. Partial volume correction and noise reduction improved CSH curves. Both simulations and clinical examples showed that AUC-CSH values corresponded with level of tumour heterogeneity and/or heterogeneity in response. In contrast, this correspondence was not seen with SUV{sub max} alone. The results indicate that the main advantage of AUC-CSH above other measures, such as 1/COV (coefficient of variation), is the possibility to measure or normalize AUC-CSH in different ways. AUC-CSH might be used as a quantitative index of heterogeneity in tracer uptake. In response monitoring studies it can be used to address heterogeneity in response. (orig.)

  12. The accuracy of MRI-determined synovial membrane and joint effusion volumes in arthritis. A comparison of pre- and post-aspiration volumes

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Stoltenberg, M; Henriksen, O

    1995-01-01

    Magnetic resonance imaging (MRI) of 18 knees of patients with arthritis was performed before and immediately after arthrocentesis. Pre- and post-aspiration volumes were calculated by adding the outlined areas of synovium/effusion from a continuous series of gadolinium-DTPA-enhanced 5 mm transversal...... T1-weighted MR-images. The difference between MRI-determined and syringe-determined volumes of aspirated joint fluid was 0-7 ml, median 2 ml, corresponding to 0-18%, median 7%, of the pre-aspiration effusion volume. Synovial membrane volumes, determined before and after arthrocentesis varied 0-10 ml......, median 3 ml (0-17%, median 7%). No significant systematic misinterpretation of the borderline between joint fluid and synovium was found. We conclude that effusion volumes and in all probability also synovial membrane volumes, can be determined by MRI with a maximal analytical error of approximately 20...

  13. Theoretical Study of the BaTiO3 Powder’s Volume Ratio’s Influence on the Output of Composite Piezoelectric Nanogenerator

    Directory of Open Access Journals (Sweden)

    Xi Zhou

    2017-06-01

    Full Text Available The combination of the piezoelectric materials and polymer is an effective way to make the piezoelectric nanogenerator (PENG possess both the polymer’s good flexibility and ferroelectric material’s high piezoelectric coefficient. The volume ratio of ferroelectric material in the composite is an important factor that determines the PENG’s output performance. In this paper, the BaTiO3/polydimethylsiloxane (PDMS composite PENG was demonstrated as having an optimal volume ratio (46% at which the PENG can output its highest voltage, and this phenomenon can be ascribed to the trade-off between the composite PENG’s top electrode charge and its capacitance. These results are of practical importance for the composite PENG’s performance optimization.

  14. Recurrent major depression and right hippocampal volume: A bivariate linkage and association study.

    Science.gov (United States)

    Mathias, Samuel R; Knowles, Emma E M; Kent, Jack W; McKay, D Reese; Curran, Joanne E; de Almeida, Marcio A A; Dyer, Thomas D; Göring, Harald H H; Olvera, Rene L; Duggirala, Ravi; Fox, Peter T; Almasy, Laura; Blangero, John; Glahn, David C

    2016-01-01

    Previous work has shown that the hippocampus is smaller in the brains of individuals suffering from major depressive disorder (MDD) than those of healthy controls. Moreover, right hippocampal volume specifically has been found to predict the probability of subsequent depressive episodes. This study explored the utility of right hippocampal volume as an endophenotype of recurrent MDD (rMDD). We observed a significant genetic correlation between the two traits in a large sample of Mexican American individuals from extended pedigrees (ρg = -0.34, p = 0.013). A bivariate linkage scan revealed a significant pleiotropic quantitative trait locus on chromosome 18p11.31-32 (LOD = 3.61). Bivariate association analysis conducted under the linkage peak revealed a variant (rs574972) within an intron of the gene SMCHD1 meeting the corrected significance level (χ(2) = 19.0, p = 7.4 × 10(-5)). Univariate association analyses of each phenotype separately revealed that the same variant was significant for right hippocampal volume alone, and also revealed a suggestively significant variant (rs12455524) within the gene DLGAP1 for rMDD alone. The results implicate right-hemisphere hippocampal volume as a possible endophenotype of rMDD, and in so doing highlight a potential gene of interest for rMDD risk. © 2015 Wiley Periodicals, Inc.

  15. Oxygen concentrators performance with nitrous oxide at 50:50 volume

    Directory of Open Access Journals (Sweden)

    Jorge Ronaldo Moll

    2014-06-01

    Full Text Available Background and objectives: Few investigations have addressed the safety of oxygen from concentrators for use in anesthesia in association with nitrous oxide. This study evaluated the percent of oxygen from a concentrator in association with nitrous oxide in a semi-closed rebreathing circuit. Methods: Adult patients undergoing low risk surgery were randomly allocated into two groups, receiving a fresh gas flow of oxygen from concentrators (O293 or of oxygen from concentrators and nitrous oxide (O293N2O. The fraction of inspired oxygen and the percentage of oxygen from fresh gas flow were measured every 10 min. The ratio of FiO2/oxygen concentration delivered was compared at various time intervals and between the groups. Results: Thirty patients were studied in each group. There was no difference in oxygen from concentrators over time for both groups, but there was a significant improvement in the FiO2 (p < 0.001 for O293 group while a significant decline (p < 0.001 for O293N2O. The FiO2/oxygen ratio varied in both groups, reaching a plateau in the O293 group. Pulse oximetry did not fall below 98.5% in either group. Conclusion: The FiO2 in the mixture of O293 and nitrous oxide fell during the observation period although oxygen saturation was higher than 98.5% throughout the study. Concentrators can be considered a stable source of oxygen for use during short anesthetic procedures, either pure or in association with nitrous oxide at 50:50 volume.

  16. Colorectal Surgery Fellowship Improves In-hospital Mortality After Colectomy and Proctectomy Irrespective of Hospital and Surgeon Volume.

    Science.gov (United States)

    Saraidaridis, Julia T; Hashimoto, Daniel A; Chang, David C; Bordeianou, Liliana G; Kunitake, Hiroko

    2018-03-01

    General surgery residents are increasingly pursuing sub-specialty training in colorectal (CR) surgery. However, the majority of operations performed by CR surgeons are also performed by general surgeons. This study aimed to assess in-hospital mortality stratified by CR training status after adjusting for surgeon and hospital volume. The Statewide Planning and Research Cooperative system database was used to identify all patients who underwent colectomy/proctectomy from January 1, 2000, to December 31, 2014, in the state of New York. Operations performed by board-certified CR surgeons were identified. The relationships between CR board certification and in-hospital mortality, in-hospital complications, length of stay, and ostomy were assessed using multivariate regression models. Two hundred seventy thousand six hundred eighty-four patients underwent colectomy/proctectomy over the study period. Seventy-two thousand two hundred seventy-nine (26.7%) of operations were performed by CR surgeons. Without adjusting for hospital and surgeon volume, in-hospital mortality was lower for those undergoing colectomy/proctectomy by a CR surgeon (OR 0.49, CI 0.44-0.54, p = 0.001). After controlling for hospital and surgeon volume, the odds of inpatient mortality after colectomy/proctectomy for those operated on by CR surgeons weakened to 0.76 (CI 0.68-0.86, p = 0.001). Hospital and surgeon volume accounted for 53% of the reduction in in-hospital mortality when CR surgeons performed colectomy/proctectomy. Patients who underwent surgery by a CR surgeon had a shorter inpatient stay (0.8 days, p = 0.001) and a decreased chance of colostomy (OR 0.86, CI 0.78-0.95, p accounting for hospital and surgeon volume.

  17. Study on the performance improvement of the high temperature superconducting coil with several separated coils at the edges

    International Nuclear Information System (INIS)

    Ishiguri, S.; Oka, T.; Fukui, S.; Ogawa, J.; Sato, T.

    2008-01-01

    In designing high temperature superconducting (HTS) coils, it is important to secure large magnetic fields and stored energy using shorter tape length. Thus, it is necessary to improve the transport current performance of the coils. The critical current and n-value of an HTS tape depend on magnetic fields and flux angles under constant temperature. Considering these dependencies, we established a model to analyze coil critical current. This model clarifies that relatively large electric fields are generated at the coil edges. This adversely affects the transport current performance. In this study, the coil edge is separated into several coils, keeping the total tape length constant. This increases the coil critical current, stored energy, central magnetic field, and also the coil volume, which contains vacancies created by the separation. To estimate coil performance, we calculated the stored energy density, whose denominator is the increased coil volume. This stored energy density reaches its maximum value when the number of the separated coils is eight. At this optimum separation, the central magnetic field increases by 13%, and the stored energy improves by 43%, compared to a rectangular coil wound with the same tape length

  18. Study on the barrier performance of molten solidified waste (I). Review of the performance assessment research

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Toshikatsu; Sakamoto, Yoshiaki; Nakayama, Shinichi; Yamaguchi, Tetsuji; Ogawa, Hiromichi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-02-01

    Application of melting technique is thought as one of the effective methods to treatment of the waste from the view point of its homogeneity and waste volume reduction. Solidified products by melting are expected as potential candidates of engineered barrier in a repository due to the good properties for their stabilization of radionuclides and hazardous elements. However, the methodology of performance evaluation has not been estimated so far. In this report, a literature survey on the properties of molten solidified waste was performed. It is clarified that the leachability of waste elements such as Co or Sr in molten waste form would be controlled by the corrosion behaviors of iron or silica which are the matrix elements of the waste form. While, no investigations into the durability of waste form have performed so far. Also noticed that the research items on performance evaluation such as the leachability for long-lived radionuclides and durability of waste form would be necessary for the long-term barrier assessment on the disposal. (author)

  19. Effect of Esophageal Cancer Surgeon Volume on Management and Mortality From Emergency Upper Gastrointestinal Conditions: Population-based Cohort Study.

    Science.gov (United States)

    Markar, Sheraz R; Mackenzie, Hugh; Askari, Alan; Faiz, Omar; Hanna, George B

    2017-11-01

    To study the influence of esophageal cancer surgeon volume upon mortality from upper gastrointestinal emergencies. Volume-outcome relationships led to the centralization of esophageal cancer surgery. Hospital Episode Statistics data were used to identify patients admitted to hospitals within England (1997-2012). The influence of esophageal high-volume (HV) cancer surgeon status (≥5 resections per year) upon 30-day and 90-day mortality from esophageal perforation (EP), paraesophageal hernia causing obstruction or gangrene (PEH) and perforated peptic ulcer (PPU) was analyzed, independent of HV esophageal cancer center status and patient and disease-specific confounding factors. A total of 3707, 12,411, and 57,164 patients with EP, PEH, and PPU, respectively, were included. The observed 90-day mortality was 36.5%, 11.5%, and 29.0% for EP, PEH, and PPU, respectively.Management by HV cancer surgeon was independently associated with significant reductions in 30-day and 90-day mortality from EP (odds ratio, OR 0.51, 95% confidence interval, CI, 0.40-0.66), PEH (OR=0.70, 95% CI 0.53-0.91), and PPU (OR=0.85, 95% CI 0.7-0.95). Subset analysis of those patients receiving primary surgery as treatment showed no change in mortality when performed by HV cancer surgeons.However HV cancer surgeons performed surgery as primary treatment more commonly for EP (OR=2.38, 95% CI 1.87-3.04) and PEH (OR=2.12, 95% CI 1.79-2.51). Furthermore surgery was independently associated with reduced mortality for all 3 conditions. The complex elective workload of HV esophageal cancer surgeons appears to lower the threshold for surgical intervention in specific upper gastrointestinal emergencies such as EP and PEH, which in turn reduces mortality.

  20. Automated planning volume definition in soft-tissue sarcoma adjuvant brachytherapy

    International Nuclear Information System (INIS)

    Lee, Eva K.; Fung, Albert Y.C.; Zaider, Marco; Brooks, J. Paul

    2002-01-01

    In current practice, the planning volume for adjuvant brachytherapy treatment for soft-tissue sarcoma is either not determined a priori (in this case, seed locations are selected based on isodose curves conforming to a visual estimate of the planning volume), or it is derived via a tedious manual process. In either case, the process is subjective and time consuming, and is highly dependent on the human planner. The focus of the work described herein involves the development of an automated contouring algorithm to outline the planning volume. Such an automatic procedure will save time and provide a consistent and objective method for determining planning volumes. In addition, a definitive representation of the planning volume will allow for sophisticated brachytherapy treatment planning approaches to be applied when designing treatment plans, so as to maximize local tumour control and minimize normal tissue complications. An automated tumour volume contouring algorithm is developed utilizing computational geometry and numerical interpolation techniques in conjunction with an artificial intelligence method. The target volume is defined to be the slab of tissue r cm perpendicularly away from the curvilinear plane defined by the mesh of catheters. We assume that if adjacent catheters are over 2r cm apart, the tissue between the two catheters is part of the tumour bed. Input data consist of the digitized coordinates of the catheter positions in each of several cross-sectional slices of the tumour bed, and the estimated distance r from the catheters to the tumour surface. Mathematically, one can view the planning volume as the volume enclosed within a minimal smoothly-connected surface which contains a set of circles, each circle centred at a given catheter position in a given cross-sectional slice. The algorithm performs local interpolation on consecutive triplets of circles. The effectiveness of the algorithm is evaluated based on its performance on a collection of

  1. Automated planning volume definition in soft-tissue sarcoma adjuvant brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eva K. [Department of Radiation Oncology, Emory University School of Medicine, Atlanta, GA (United States); School of Industrial and Systems Engineering, Georgia Institute of Technology, Atlanta, GA (United States); Fung, Albert Y.C.; Zaider, Marco [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY (United States); Brooks, J. Paul [School of Industrial and Systems Engineering, Georgia Institute of Technology, Atlanta, GA (United States)

    2002-06-07

    In current practice, the planning volume for adjuvant brachytherapy treatment for soft-tissue sarcoma is either not determined a priori (in this case, seed locations are selected based on isodose curves conforming to a visual estimate of the planning volume), or it is derived via a tedious manual process. In either case, the process is subjective and time consuming, and is highly dependent on the human planner. The focus of the work described herein involves the development of an automated contouring algorithm to outline the planning volume. Such an automatic procedure will save time and provide a consistent and objective method for determining planning volumes. In addition, a definitive representation of the planning volume will allow for sophisticated brachytherapy treatment planning approaches to be applied when designing treatment plans, so as to maximize local tumour control and minimize normal tissue complications. An automated tumour volume contouring algorithm is developed utilizing computational geometry and numerical interpolation techniques in conjunction with an artificial intelligence method. The target volume is defined to be the slab of tissue r cm perpendicularly away from the curvilinear plane defined by the mesh of catheters. We assume that if adjacent catheters are over 2r cm apart, the tissue between the two catheters is part of the tumour bed. Input data consist of the digitized coordinates of the catheter positions in each of several cross-sectional slices of the tumour bed, and the estimated distance r from the catheters to the tumour surface. Mathematically, one can view the planning volume as the volume enclosed within a minimal smoothly-connected surface which contains a set of circles, each circle centred at a given catheter position in a given cross-sectional slice. The algorithm performs local interpolation on consecutive triplets of circles. The effectiveness of the algorithm is evaluated based on its performance on a collection of

  2. ICPP calcined solids storage facility closure study. Volume III: Engineering design files

    International Nuclear Information System (INIS)

    1998-02-01

    The following information was calculated to support cost estimates and radiation exposure calculations for closure activities at the Calcined Solids Storage Facility (CSSF). Within the estimate, volumes were calculated to determine the required amount of grout to be used during closure activities. The remaining calcine on the bin walls, supports, piping, and floor was also calculated to approximate the remaining residual calcine volumes at different stages of the removal process. The estimates for remaining calcine and vault void volume are higher than what would actually be experienced in the field, but are necessary for bounding purposes. The residual calcine in the bins may be higher than was is experienced in the field as it was assumed that the entire bin volume is full of calcine before removal activities commence. The vault void volumes are higher as the vault roof beam volumes were neglected. The estimations that follow should be considered rough order of magnitude, due to the time constraints as dictated by the project's scope of work. Should more accurate numbers be required, a new analysis would be necessary

  3. ICPP calcined solids storage facility closure study. Volume III: Engineering design files

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    The following information was calculated to support cost estimates and radiation exposure calculations for closure activities at the Calcined Solids Storage Facility (CSSF). Within the estimate, volumes were calculated to determine the required amount of grout to be used during closure activities. The remaining calcine on the bin walls, supports, piping, and floor was also calculated to approximate the remaining residual calcine volumes at different stages of the removal process. The estimates for remaining calcine and vault void volume are higher than what would actually be experienced in the field, but are necessary for bounding purposes. The residual calcine in the bins may be higher than was is experienced in the field as it was assumed that the entire bin volume is full of calcine before removal activities commence. The vault void volumes are higher as the vault roof beam volumes were neglected. The estimations that follow should be considered rough order of magnitude, due to the time constraints as dictated by the project`s scope of work. Should more accurate numbers be required, a new analysis would be necessary.

  4. Assessment of in vivo MR imaging compared to physical sections in vitro-A quantitative study of brain volumes using stereology

    DEFF Research Database (Denmark)

    Jelsing, Jacob; Rostrup, Egill; Markenroth, Karin

    2005-01-01

    The object of the present study was to compare stereological estimates of brain volumes obtained in vivo by magnetic resonance imaging (MRI) to corresponding volumes from physical sections in vitro. Brains of ten domestic pigs were imaged using a 3-T scanner. The volumes of different brain....... However, although intraobserver difference of MRI estimates was acceptable, the interobserver difference was not. A statistical highly significant difference of 11-41% was observed between observers for volume estimates of all compartments considered. The study demonstrates that quantitative MRI...

  5. Association Between Pain at Sites Outside the Knee and Knee Cartilage Volume Loss in Elderly People Without Knee Osteoarthritis: A Prospective Study.

    Science.gov (United States)

    Pan, Feng; Laslett, Laura; Tian, Jing; Cicuttini, Flavia; Winzenberg, Tania; Ding, Changhai; Jones, Graeme

    2017-05-01

    Pain is common in the elderly. Knee pain may predict knee cartilage loss, but whether generalized pain is associated with knee cartilage loss is unclear. This study, therefore, aimed to determine whether pain at multiple sites predicts knee cartilage volume loss among community-dwelling older adults, and, if so, to explore potential mechanisms. Data from the prospective Tasmanian Older Adult Cohort study was utilized (n = 394, mean age 63 years, range 52-79 years). Experience of pain at multiple sites was assessed using a questionnaire at baseline. T1-weighted fat-saturated magnetic resonance imaging of the right knee was performed to assess the cartilage volume at baseline and after 2.6 years. Linear regression modeling was used with adjustment for potential confounders. The median number of painful sites was 3 (range 0-7). There was a dose-response relationship between the number of painful sites and knee cartilage volume loss in the lateral and total tibiofemoral compartments (lateral β = -0.28% per annum; total β = -0.25% per annum, both P for trend knee osteoarthritis (OA) (P pain medication, and knee structural abnormalities. The number of painful sites independently predicts knee cartilage volume loss, especially in people without knee OA, suggesting that widespread pain may be an early marker of more rapid knee cartilage loss in those without radiographic knee OA. The underlying mechanism is unclear, but it is independent of anthropometrics, physical activity, and knee structural abnormalities. © 2016, American College of Rheumatology.

  6. Volume 1: Survey of Available Information in Support of the Energy-Water Bandwidth Study of Desalination Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Prakash [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Aghajanzadeh, Arian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sheaffer, Paul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Morrow, William R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Brueske, Sabine [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dollinger, Caroline [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Kevin [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sarker, Prateeti [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ward, Nicholas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cresko, Joe [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-10-01

    The U.S. Department of Energy (DOE) has set a goal to reduce the cost of seawater desalination systems to $0.50/ cubic meter (m3) through the development of technology pathways to reduce energy, capital, operating, soft, and system integration costs.1 In support of this goal and to evaluate the technology pathways to lower the energy and carbon intensity of desalination while also reducing the total water cost, DOE is undertaking a comprehensive study of the energy consumption and carbon dioxide (CO2) emissions for desalination technologies and systems. This study is being undertaken in two phases. Phase 1, Survey of Available Information in Support of the Energy-Water Bandwidth Study of Desalination Systems, collected the background information that will underpin Phase 2, the Energy Water Bandwidth Study for Desalination Systems. This report (Volume 1) summarizes the results from Phase 1. The results from Phase 2 will be summarized in Volume 2: Energy Water Bandwidth Study for Desalination Systems (Volume 2). The analysis effort for Phase 2 will utilize similar methods as other industry-specific Energy Bandwidth Studies developed by DOE,2 which has provided a framework to evaluate and compare energy savings potentials within and across manufacturing sectors at the macroscale. Volume 2 will assess the current state of desalination energy intensity and reduction potential through the use of advanced and emerging technologies. For the purpose of both phases of study, energy intensity is defined as the amount of energy required per unit of product water output (for example, kilowatt-hours per cubic meter of water produced). These studies will expand the scope of previous sectorial bandwidth studies by also evaluating CO2 intensity and reduction opportunities and informing a techno-economic analysis of desalination systems. Volume 2 is expected to be completed in 2017.

  7. Experimental study on the performance of a liquid cooling garment with the application of MEPCMS

    International Nuclear Information System (INIS)

    Wang, Tao; Wang, Liang; Bai, Lizhan; Lin, Guiping; Bu, Xueqin; Liu, Xiangyang; Xie, Guanghui

    2015-01-01

    Highlights: • MEPCMS was applied in a liquid cooling garment for space applications. • Extensive experimental study on the performance of the LCG was conducted. • LCG was assessed by heat dissipation, temperature control and thermal comfort. • Proper match of relevant parameters was crucial in enhancing LCG performance. • 26% enhancement in heat dissipation was achieved by MEPCMS compared to water. - Abstract: As a novel working fluid, microencapsulated phase change material suspension (MEPCMS) exhibits obvious superiority in both heat transfer and temperature control compared with traditional ones. In this paper, extensive experimental study on the performance of a liquid cooling garment (LCG) with the application of this novel working fluid was conducted for future space applications. The main task for a LCG is to efficiently collect, transport and dissipate the metabolic heat produced from the human body. In the experiment, a thermal manikin was employed to simulate the human body, and the performance of the LCG with MEPCMS as the working fluid was evaluated by a variety of aspects such as heat dissipation, temperature control, pump power consumption and thermal comfort under both steady state and transient conditions. Experimental results show that the inlet temperature, mass flowrate and volume concentration of the MEPCMS are three key parameters affecting the performance of the LCG, which can be enhanced significantly by a proper combination of these parameters. Otherwise, the performance of the LCG will deteriorate or even be worse than that using water as the working fluid. When the inlet temperature, mass flowrate and volume concentration of the MEPCMS were selected as 11 °C, 200 g/min and 20% respectively, the heat dissipation of the LCG was enhanced by up to 26% with no obvious increase of the pump power compared with that using water as the working fluid, the temperature distribution in the human body became more uniform, and the capability

  8. Volume-Dependent Overestimation of Spontaneous Intracerebral Hematoma Volume by the ABC/2 Formula

    International Nuclear Information System (INIS)

    Chih-Wei Wang; Chun-Jung Juan; Hsian-He Hsu; Hua-Shan Liu; Cheng-Yu Chen; Chun-Jen Hsueh; Hung-Wen Kao; Guo-Shu Huang; Yi-Jui Liu; Chung-Ping Lo

    2009-01-01

    Background: Although the ABC/2 formula has been widely used to estimate the volume of intracerebral hematoma (ICH), the formula tends to overestimate hematoma volume. The volume-related imprecision of the ABC/2 formula has not been documented quantitatively. Purpose: To investigate the volume-dependent overestimation of the ABC/2 formula by comparing it with computer-assisted volumetric analysis (CAVA). Material and Methods: Forty patients who had suffered spontaneous ICH and who had undergone non-enhanced brain computed tomography scans were enrolled in this study. The ICH volume was estimated based on the ABC/2 formula and also calculated by CAVA. Based on the ICH volume calculated by the CAVA method, the patients were divided into three groups: group 1 consisted of 17 patients with an ICH volume of less than 20 ml; group 2 comprised 13 patients with an ICH volume of 20 to 40 ml; and group 3 was composed of 10 patients with an ICH volume larger than 40 ml. Results: The mean estimated hematoma volume was 43.6 ml when using the ABC/2 formula, compared with 33.8 ml when using the CAVA method. The mean estimated difference was 1.3 ml, 4.4 ml, and 31.4 ml for groups 1, 2, and 3, respectively, corresponding to an estimation error of 9.9%, 16.7%, and 37.1% by the ABC/2 formula (P<0.05). Conclusion: The ABC/2 formula significantly overestimates the volume of ICH. A positive association between the estimation error and the volume of ICH is demonstrated

  9. Cerebellar contribution to motor and cognitive performance in multiple sclerosis: An MRI sub-regional volumetric analysis.

    Science.gov (United States)

    D'Ambrosio, Alessandro; Pagani, Elisabetta; Riccitelli, Gianna C; Colombo, Bruno; Rodegher, Mariaemma; Falini, Andrea; Comi, Giancarlo; Filippi, Massimo; Rocca, Maria A

    2017-08-01

    To investigate the role of cerebellar sub-regions on motor and cognitive performance in multiple sclerosis (MS) patients. Whole and sub-regional cerebellar volumes, brain volumes, T2 hyperintense lesion volumes (LV), and motor performance scores were obtained from 95 relapse-onset MS patients and 32 healthy controls (HC). MS patients also underwent an evaluation of working memory and processing speed functions. Cerebellar anterior and posterior lobes were segmented using the Spatially Unbiased Infratentorial Toolbox (SUIT) from Statistical Parametric Mapping (SPM12). Multivariate linear regression models assessed the relationship between magnetic resonance imaging (MRI) measures and motor/cognitive scores. Compared to HC, only secondary progressive multiple sclerosis (SPMS) patients had lower cerebellar volumes (total and posterior cerebellum). In MS patients, lower anterior cerebellar volume and brain T2 LV predicted worse motor performance, whereas lower posterior cerebellar volume and brain T2 LV predicted poor cognitive performance. Global measures of brain volume and infratentorial T2 LV were not selected by the final multivariate models. Cerebellar volumetric abnormalities are likely to play an important contribution to explain motor and cognitive performance in MS patients. Consistently with functional mapping studies, cerebellar posterior-inferior volume accounted for variance in cognitive measures, whereas anterior cerebellar volume accounted for variance in motor performance, supporting the assessment of cerebellar damage at sub-regional level.

  10. Outcomes of PCI in Relation to Procedural Characteristics and Operator Volumes in the United States.

    Science.gov (United States)

    Fanaroff, Alexander C; Zakroysky, Pearl; Dai, David; Wojdyla, Daniel; Sherwood, Matthew W; Roe, Matthew T; Wang, Tracy Y; Peterson, Eric D; Gurm, Hitinder S; Cohen, Mauricio G; Messenger, John C; Rao, Sunil V

    2017-06-20

    Professional guidelines have reduced the recommended minimum number to an average of 50 percutaneous coronary intervention (PCI) procedures performed annually by each operator. Operator volume patterns and associated outcomes since this change are unknown. The authors describe herein PCI operator procedure volumes; characteristics of low-, intermediate-, and high-volume operators; and the relationship between operator volume and clinical outcomes in a large, contemporary, nationwide sample. Using data from the National Cardiovascular Data Registry collected between July 1, 2009, and March 31, 2015, we examined operator annual PCI volume. We divided operators into low- (100 PCIs per year) volume groups, and determined the adjusted association between annual PCI volume and in-hospital outcomes, including mortality. The median annual number of procedures performed per operator was 59; 44% of operators performed PCI procedures per year. Low-volume operators more frequently performed emergency and primary PCI procedures and practiced at hospitals with lower annual PCI volumes. Unadjusted in-hospital mortality was 1.86% for low-volume operators, 1.73% for intermediate-volume operators, and 1.48% for high-volume operators. The adjusted risk of in-hospital mortality was higher for PCI procedures performed by low- and intermediate-volume operators compared with those performed by high-volume operators (adjusted odds ratio: 1.16 for low versus high; adjusted odds ratio: 1.05 for intermediate vs. high volume) as was the risk for new dialysis post PCI. No volume relationship was observed for post-PCI bleeding. Many PCI operators in the United States are performing fewer than the recommended number of PCI procedures annually. Although absolute risk differences are small and may be partially explained by unmeasured differences in case mix between operators, there remains an inverse relationship between PCI operator volume and in-hospital mortality that persisted in risk

  11. Age-Modulated Associations between KIBRA, Brain Volume, and Verbal Memory among Healthy Older Adults

    Directory of Open Access Journals (Sweden)

    Ariana Stickel

    2018-01-01

    Full Text Available The resource modulation hypothesis suggests that the influence of genes on cognitive functioning increases with age. The KIBRA single nucleotide polymorphism rs17070145, associated with episodic memory and working memory, has been suggested to follow such a pattern, but few studies have tested this assertion directly. The present study investigated the relationship between KIBRA alleles (T carriers vs. CC homozygotes, cognitive performance, and brain volumes in three groups of cognitively healthy adults—middle aged (ages 52–64, n = 38, young old (ages 65–72, n = 45, and older old (ages 73–92, n = 62—who were carefully matched on potentially confounding variables including apolipoprotein ε4 status and hypertension. Consistent with our prediction, T carriers maintained verbal memory performance with increasing age while CC homozygotes declined. Voxel-based morphometric analysis of magnetic resonance images showed an advantage for T carriers in frontal white matter volume that increased with age. Focusing on the older old group, this advantage for T carriers was also evident in left lingual gyrus gray matter and several additional frontal white matter regions. Contrary to expectations, neither KIBRA nor the interaction between KIBRA and age predicted hippocampal volumes. None of the brain regions investigated showed a CC homozygote advantage. Taken together, these data suggest that KIBRA results in decreased verbal memory performance and lower brain volumes in CC homozygotes compared to T carriers, particularly among the oldest old, consistent with the resource modulation hypothesis.

  12. Sound perception, performance

    CERN Document Server

    2013-01-01

    Musical Performance covers many aspects like Musical Acoustics, Music Psychology, or motor and prosodic actions. It deals with basic concepts of the origin or music and its evolution, ranges over neurocognitive foundations, and covers computational, technological, or simulation solutions. This volume gives an overview about current research in the foundation of musical performance studies on all these levels. Recent concepts of synchronized systems, evolutionary concepts, basic understanding of performance as Gestalt patterns, theories of chill as performance goals or historical aspects are covered. The neurocognitive basis of motor action in terms of music, musical syntax, as well as therapeutic aspects are discussed. State-of-the-art applications in performance realizations, like virtual room acoustics, virtual musicians, new concepts of real-time physical modeling using complex performance data as input or sensor and gesture studies with soft- and hardware solutions are presented. So although the field is ...

  13. Variability of Arthroscopy Case Volume in Orthopaedic Surgery Residency.

    Science.gov (United States)

    Gil, Joseph A; Waryasz, Gregory R; Owens, Brett D; Daniels, Alan H

    2016-05-01

    To examine orthopaedic surgery case logs for arthroscopy case volume during residency training and to evaluate trends in case volume and variability over time. Publicly available Accreditation Council for Graduate Medical Education surgical case logs from 2007 to 2013 for orthopaedic surgery residency were assessed for variability and case volume trends in shoulder, elbow, wrist, hip, knee, and ankle arthroscopy. The national average number of procedures performed in each arthroscopy category reported was directly compared from 2009 to 2013. The 10th and 90th percentile arthroscopy case volume was compared between 2007 and 2013 for shoulder and knee arthroscopy procedures. Subsequently, the difference between the 10th and 90th percentile arthroscopy case volume in each category in 2007 was compared with the difference between the 10th and 90th percentile arthroscopy case volume in each category in 2013. From 2007 to 2013, shoulder arthroscopy procedures performed per resident increased by 43.1% (P = .0001); elbow arthroscopy procedures increased by 28.0% (P = .00612); wrist arthroscopy procedures increased by 8.6% (P = .05); hip arthroscopy procedures, which were first reported in 2012, increased by 588.9%; knee arthroscopy procedures increased by 8.5% (P = .0435); ankle arthroscopy increased by 27.6% (P = .00149). The difference in knee and shoulder arthroscopy volume between residents in the 10th and 90th percentile in 2007 and residents in the 10th and 90th percentile in 2013 was not significant (P > .05). There was a 3.66-fold difference in knee arthroscopy volume between residents in the 10th and 90th percentile in 2007, whereas the difference was 3.36-fold in 2013 (P = .70). There was a 5.86-fold difference in shoulder arthroscopy case volume between residents in the 10th and 90th percentile in 2007, whereas the difference was 4.96-fold in 2013 (P = .29). The volume of arthroscopy cases performed by graduating orthopaedic surgery residents has

  14. The Canada country study: Climate impacts and adaptation -- Vol. 7: National sectoral volume

    Energy Technology Data Exchange (ETDEWEB)

    Koshida, G.; Avis, W. [eds.] [Environment Canada, Downsview, ON (Canada)

    1998-10-01

    The Canada Country Study is a comprehensive source of knowledge on how climate change could impact on communities across Canada. The Study consists of a series of eight volumes and constitutes the scientific and technical results of the assessment phase of the project. This volume (Vol. 7) contains 12 sectoral papers which provide a digest of the findings of the previous six regional volumes, but viewed from the vantage points of the various sectors of national life and the economy, i.e. (1) agriculture, (2) built environment, (3) energy, (4) fisheries, (5) forestry, (6) human health, (7) insurance, (8) recreation and tourism, (9) transportation, (10) unmanaged ecosystems, (11) water resources, and (12) wetlands. Each paper is accompanied by an extensive list of references, a list of tables, a list of figures, and a list of appendices. Readers are cautioned that confidence levels are higher in the hemispheric-to-continental projections of climate change than in the regional projections. Also, it should be borne in mind that the identified changes in climate are projected to occur over the next century, and that the average rate of warming used in the models underlying these projections may be greater than any seen in the last several millenia.

  15. A Study of the Transient Response of Duct Junctions: Measurements and Gas-Dynamic Modeling with a Staggered Mesh Finite Volume Approach

    Directory of Open Access Journals (Sweden)

    Antonio J. Torregrosa

    2017-05-01

    Full Text Available Duct junctions play a major role in the operation and design of most piping systems. The objective of this paper is to establish the potential of a staggered mesh finite volume model as a way to improve the description of the effect of simple duct junctions on an otherwise one-dimensional flow system, such as the intake or exhaust of an internal combustion engine. Specific experiments have been performed in which different junctions have been characterized as a multi-port, and that have provided precise and reliable results on the propagation of pressure pulses across junctions. The results obtained have been compared to simulations performed with a staggered mesh finite volume method with different flux limiters and different meshes and, as a reference, have also been compared with the results of a more conventional pressure loss-based model. The results indicate that the staggered mesh finite volume model provides a closer description of wave dynamics, even if further work is needed to establish the optimal calculation settings.

  16. Estimation of gas and tissue lung volumes by MRI: functional approach of lung imaging.

    Science.gov (United States)

    Qanadli, S D; Orvoen-Frija, E; Lacombe, P; Di Paola, R; Bittoun, J; Frija, G

    1999-01-01

    The purpose of this work was to assess the accuracy of MRI for the determination of lung gas and tissue volumes. Fifteen healthy subjects underwent MRI of the thorax and pulmonary function tests [vital capacity (VC) and total lung capacity (TLC)] in the supine position. MR examinations were performed at inspiration and expiration. Lung volumes were measured by a previously validated technique on phantoms. Both individual and total lung volumes and capacities were calculated. MRI total vital capacity (VC(MRI)) was compared with spirometric vital capacity (VC(SP)). Capacities were correlated to lung volumes. Tissue volume (V(T)) was estimated as the difference between the total lung volume at full inspiration and the TLC. No significant difference was seen between VC(MRI) and VC(SP). Individual capacities were well correlated (r = 0.9) to static volume at full inspiration. The V(T) was estimated to be 836+/-393 ml. This preliminary study demonstrates that MRI can accurately estimate lung gas and tissue volumes. The proposed approach appears well suited for functional imaging of the lung.

  17. The importance of tumor volume in the prognosis of patients with glioblastoma. Comparison of computerized volumetry and geometric models

    International Nuclear Information System (INIS)

    Iliadis, Georgios; Misailidou, Despina; Selviaridis, Panagiotis; Chatzisotiriou, Athanasios; Kalogera-Fountzila, Anna; Fragkoulidi, Anna; Fountzilas, George; Baltas, Dimos; Tselis, Nikolaos; Zamboglou, Nikolaos

    2009-01-01

    Background and purpose: the importance of tumor volume as a prognostic factor in high-grade gliomas is highly controversial and there are numerous methods estimating this parameter. In this study, a computer-based application was used in order to assess tumor volume from hard copies and a survival analysis was conducted in order to evaluate the prognostic significance of preoperative volumetric data in patients harboring glioblastomas. Patients and methods: 50 patients suffering from glioblastoma were analyzed retrospectively. Tumor volume was determined by the various geometric models as well as by an own specialized software (Volumio). Age, performance status, type of excision, and tumor location were also included in the multivariate analysis. Results: the spheroid and rectangular models overestimated tumor volume, while the ellipsoid model offered the best approximation. Volume failed to attain any statistical significance in prognosis, while age and performance status confirmed their importance in progression-free and overall survival of patients. Conclusion: geometric models provide a rough approximation of tumor volume and should not be used, as accurate determination of size is of paramount importance in order to draw safe conclusions in oncology. Although the significance of volumetry was not disclosed, further studies are definitely required. (orig.)

  18. ACCURATUM: improved calcium volume scoring using a mesh-based algorithm - a phantom study

    International Nuclear Information System (INIS)

    Saur, Stefan C.; Szekely, Gabor; Alkadhi, Hatem; Desbiolles, Lotus; Cattin, Philippe C.

    2009-01-01

    To overcome the limitations of the classical volume scoring method for quantifying coronary calcifications, including accuracy, variability between examinations, and dependency on plaque density and acquisition parameters, a mesh-based volume measurement method has been developed. It was evaluated and compared with the classical volume scoring method for accuracy, i.e., the normalized volume (measured volume/ground-truthed volume), and for variability between examinations (standard deviation of accuracy). A cardiac computed-tomography (CT) phantom containing various cylindrical calcifications was scanned using different tube voltages and reconstruction kernels, at various positions and orientations on the CT table and using different slice thicknesses. Mean accuracy for all plaques was significantly higher (p<0.0001) for the proposed method (1.220±0.507) than for the classical volume score (1.896±1.095). In contrast to the classical volume score, plaque density (p=0.84), reconstruction kernel (p=0.19), and tube voltage (p=0.27) had no impact on the accuracy of the developed method. In conclusion, the method presented herein is more accurate than classical calcium scoring and is less dependent on tube voltage, reconstruction kernel, and plaque density. (orig.)

  19. The impact of preload reduction with head-up tilt testing on longitudinal and transverse left ventricular mechanics: a study utilizing deformation volume analysis.

    Science.gov (United States)

    Schneider, Caroline; Forsythe, Lynsey; Somauroo, John; George, Keith; Oxborough, David

    2018-03-01

    Left ventricular (LV) function is dependent on load, intrinsic contractility and relaxation with a variable impact on specific mechanics. Strain (ε) imaging allows the assessment of cardiac function; however, the direct relationship between volume and strain is currently unknown. The aim of this study was to establish the impact of preload reduction through head-up tilt (HUT) testing on simultaneous left ventricular (LV) longitudinal and transverse function and their respective contribution to volume change. A focused transthoracic echocardiogram was performed on 10 healthy male participants (23 ± 3 years) in the supine position and following 1 min and 5 min of HUT testing. Raw temporal longitudinal ε (Ls) and transverse ε (Ts) values were exported and divided into 5% increments across the cardiac cycle and corresponding LV volumes were traced at each 5% increment. This provided simultaneous LV longitudinal and transverse ε and volume loops (deformation volume analysis - DVA). There was a leftward shift of the ε-volume loop from supine to 1 min and 5 min of HUT ( P  transverse thickening from supine to 1 min, which was further augmented at 5 min ( P  = 0.018). Preload reduction occurs within 1 min of HUT but does not further reduce at 5 min. This decline is associated with a decrease in longitudinal ε and concomitant increase in transverse ε. Consequently, augmented transverse relaxation appears to be an important factor in the maintenance of LV filling in the setting of reduced preload. DVA provides information on the relative contribution of mechanics to a change in LV volume and may have a role in the assessment of clinical populations. © 2018 The authors.

  20. The history of NATO TNF policy: The role of studies, analysis and exercises conference proceedings. Volume 1, Introduction and summary

    Energy Technology Data Exchange (ETDEWEB)

    Rinne, R.L. [ed.

    1994-02-01

    This conference was organized to study and analyze the role of simulation, analysis, modeling, and exercises in the history of NATO policy. The premise was not that the results of past studies will apply to future policy, but rather that understanding what influenced the decision process -- and how -- would be of value. The structure of the conference was built around discussion panels. The panels were augmented by a series of papers and presentations focusing on particular TNF events, issues, studies or exercise. The conference proceedings consist of three volumes. This volume, Volume 1, contains the conference introduction, agenda, biographical sketches of principal participants, and analytical summary of the presentations and discussion panels. Volume 2 contains a short introduction and the papers and presentations from the conference. Volume 3 contains selected papers by Brig. Gen. Robert C. Richardson III (Ret.).

  1. Cortical thickness and subcortical brain volumes in professional rugby league players

    Directory of Open Access Journals (Sweden)

    Magdalena Wojtowicz

    Full Text Available Purpose: The purpose of this study was to examine cortical thickness and subcortical volumes in professional rugby players with an extensive history of concussions compared to control subjects. Method: Participants included 24 active and former professional rugby league players [Age M(SD = 33.3(6.3; Range = 21–44] with an extensive history of concussion and 18 age- and education-matched controls with no history of neurotrauma or participation in contact sports. Participants underwent T1-weighted imaging and completed a neuropsychological battery, including two tests of memory. Whole brain cortical thickness analysis and structural volume analysis was performed using FreeSurfer version 6.0. Results: Professional rugby league players reported greater alcohol consumption (p < .001 and had significantly worse delayed recall of a visually complex design (p = .04. They did not differ from controls on other clinical outcome measures. There were no differences in cortical thickness between the groups. Professional players had smaller whole brain (p = .003, bilateral hippocampi (ps = .03, and left amygdala volumes (p = .01 compared to healthy controls. Within the players group, there were significant associations between greater alcohol use and smaller bilateral hippocampi and left amygdala volumes. There were no associations between structural volumes and history of concussions or memory performance. Conclusions: The literature examining cortical thickness in athletes with a history of multiple concussions is mixed. We did not observe differences in cortical thickness in professional rugby league players compared to controls. However, smaller subcortical volumes were found in players that were, in part, associated with greater alcohol consumption. Keywords: Volumetric MRI, Cortical thickness, Concussion, Brain morphometry, Athletes, Rugby

  2. Laser-induced incandescence: Towards quantitative soot volume fraction measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tzannis, A P; Wienbeucker, F; Beaud, P; Frey, H -M; Gerber, T; Mischler, B; Radi, P P [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    Laser-Induced Incandescence has recently emerged as a versatile tool for measuring soot volume fraction in a wide range of combustion systems. In this work we investigate the essential features of the method. LII is based on the acquisition of the incandescence of soot when heated through a high power laser pulse. Initial experiments have been performed on a model laboratory flame. The behaviour of the LII signal is studied experimentally. By applying numerical calculations we investigate the possibility to obtain two-dimensional soot volume fraction distributions. For this purpose a combination of LII with other techniques is required. This part is discussed in some extent and the future work is outlined. (author) 4 figs., 3 refs.

  3. Effect of volume expansion on systemic hemodynamics and central and arterial blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Bendtsen, F; Henriksen, Jens Henrik Sahl

    1995-01-01

    , and arterial pressure were determined before and during a volume expansion induced by infusion of a hyperosmotic galactose solution. RESULTS: During volume expansion, the central and arterial blood volume increased significantly in patients with class A and controls, whereas no significant change was found...... in patients with either class B or class C. Conversely, the noncentral blood volume increased in patients with class B and C. In both patients and controls, the cardiac output increased and the systemic vascular resistance decreased, whereas the mean arterial blood pressure did not change significantly......BACKGROUND & AIMS: Systemic vasodilatation in cirrhosis may lead to hemodynamic alterations with reduced effective blood volume and decreased arterial blood pressure. This study investigates the response of acute volume expansion on hemodynamics and regional blood volumes in patients with cirrhosis...

  4. Clinical associations of total kidney volume: the Framingham Heart Study.

    Science.gov (United States)

    Roseman, Daniel A; Hwang, Shih-Jen; Oyama-Manabe, Noriko; Chuang, Michael L; O'Donnell, Christopher J; Manning, Warren J; Fox, Caroline S

    2017-08-01

    Total kidney volume (TKV) is an imaging biomarker that may have diagnostic and prognostic utility. The relationships between kidney volume, renal function and cardiovascular disease (CVD) have not been characterized in a large community-dwelling population. This information is needed to advance the clinical application of TKV. We measured TKV in 1852 Framingham Heart Study participants (mean age 64.1 ± 9.2 years, 53% women) using magnetic resonance imaging. A healthy sample was used to define reference values. The associations between TKV, renal function and CVD risk factors were determined using multivariable logistic regression analysis. Overall, mean TKV was 278 ± 54 cm3 for women and 365 ± 66 cm3 for men. Risk factors for high TKV (>90% healthy referent size) were body surface area (BSA), diabetes, smoking and albuminuria, while age, female and estimated glomerular filtration rate (eGFR) kidney damage including albuminuria and eGFR <60 mL/min/1.73 m2, while high TKV is associated with diabetes and decreased odds of eGFR <60 mL/min/1.73 m2. Prospective studies are needed to characterize the natural progression and clinical consequences of TKV. Published by Oxford University Press on behalf of ERA-EDTA 2016. This work is written by US Government employees and is in the public domain in the US.

  5. Volume overload and adverse outcomes in chronic kidney disease: clinical observational and animal studies.

    Science.gov (United States)

    Hung, Szu-Chun; Lai, Yi-Shin; Kuo, Ko-Lin; Tarng, Der-Cherng

    2015-05-05

    Volume overload is frequently encountered and is associated with cardiovascular risk factors in patients with chronic kidney disease (CKD). However, the relationship between volume overload and adverse outcomes in CKD is not fully understood. A prospective cohort of 338 patients with stage 3 to 5 CKD was followed for a median of 2.1 years. The study participants were stratified by the presence or absence of volume overload, defined as an overhydration index assessed by bioimpedance spectroscopy exceeding 7%, the 90th percentile for the healthy population. The primary outcome was the composite of estimated glomerular filtration rate decline ≥50% or end-stage renal disease. The secondary outcome included a composite of morbidity and mortality from cardiovascular causes. Animal models were used to simulate fluid retention observed in human CKD. We found that patients with volume overload were at a higher risk of the primary and secondary end points in the adjusted Cox models. Furthermore, overhydration appears to be more important than hypertension in predicting an elevated risk. In rats subjected to unilateral nephrectomy and a high-salt diet, the extracellular water significantly increased. This fluid retention was associated with an increase in blood pressure, proteinuria, renal inflammation with macrophage infiltration and tumor necrosis factor-α overexpression, glomerular sclerosis, and cardiac fibrosis. Diuretic treatment with indapamide attenuated these changes, suggesting that fluid retention might play a role in the development of adverse outcomes. Volume overload contributes to CKD progression and cardiovascular diseases. Further research is warranted to clarify whether the correction of volume overload would improve outcomes for CKD patients. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  6. MRI volume measurement of basal ganglia volumes in patients with Tourette's syndrome

    International Nuclear Information System (INIS)

    Lu Jie; Li Kuncheng; Cao Yanxiang; Zhang Miao; Sui Xin; Zhang Xiaohua

    2009-01-01

    Objective: To evaluate MRI measurement of basal ganglia volumes in patients with Tourette's syndrome. Methods: Ten patients with Tourette's syndrome (TS) and 10 healthy volunteers were studied. Volumes of bilateral caudate, putamen and pallidum were measured, and the results were analyzed using paired t test. The basal ganglia volume was normalized according to individual brain volume. The basal ganglia volumes of TS patients were compared with normal control group using independent-sample t test. Results: In 10 healthy volunteers, volumes of the left caudate, putamen, pallidum were significantly larger compared with those of the right side (P 0.05) in TS patients. After normalized processing, the volumes of the left caudate (7.06 ± 0.48) cm 3 , putamen (8.81±1.01) cm 3 , pallidum (2.64± 0.38) cm 3 were smaller than those of control group [caudate (11.05±1.86) cm 3 , putamen (9.97± 1.11) cm 3 , pallidum (3.04±0.37) cm 3 ] (t=-6.577, -2.457, -2.376, P 3 in TS patients was significantly smaller compared with the control group (9.81±1.83) cm 3 (t=-4.258, P 0.05). Conclusion: The basal ganglia volumes were significantly decreased in patients with TS. MRI volumetric measurement was an important tool for evaluating pathologic changes of TS. (authors)

  7. Brain-derived Neurotrophic Factor (BDNF) and gray matter volume in bipolar disorder.

    Science.gov (United States)

    Poletti, S; Aggio, V; Hoogenboezem, T A; Ambrée, O; de Wit, H; Wijkhuijs, A J M; Locatelli, C; Colombo, C; Arolt, V; Drexhage, H A; Benedetti, F

    2017-02-01

    Bipolar Disorder (BD) is a severe psychiatric condition characterized by grey matter (GM) volumes reduction. Neurotrophic factors have been suggested to play a role in the neuroprogressive changes during the illness course. In particular peripheral brain-derived neurotrophic factor (BDNF) has been proposed as a potential biomarker related to disease activity and neuroprogression in BD. The aim of our study was to investigate if serum levels of BDNF are associated with GM volumes in BD patients and healthy controls (HC). We studied 36 inpatients affected by a major depressive episode in course of BD type I and 17 HC. Analysis of variance was performed to investigate the effect of diagnosis on GM volumes in the whole brain. Threshold for significance was PBDNF levels compared with HC. Reduced GM volumes in BD patients compared to HC were observed in several brain areas, encompassing the caudate head, superior temporal gyrus, insula, fusiform gyrus, parahippocampal gyrus, and anterior cingulate cortex. The interaction analysis between BDNF levels and diagnosis showed a significant effect in the middle frontal gyrus. HC reported higher BDNF levels associated with higher GM volumes, whereas no association between BDNF and GM volumes was observed in BD. Our study seems to suggest that although the production of BDNF is increased in BD possibly to prevent and repair neural damage, its effects could be hampered by underlying neuroinflammatory processes interfering with the neurodevelopmental role of BDNF. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  8. Mining exploitation of Imouraren.Complementary studies.Report of synthesis - volume I. and J. Project realization Economics variants and studies

    International Nuclear Information System (INIS)

    1980-07-01

    The object of volume I is to propose a plan for the Imouraren project realization. The study consists essentially of studies realization, supplies and construction and operator particular activities during investment period.This study : technical activities level to be attained and recommended method for their execution, project realization planning and overall complex investment costs mine, processing plant, utilities and general services, town and infrastructures. The aim of the volume J is to present studies result that have been carried out within three main directions : an essay of several procedure variants for the plant ; a modification of mining exploitation planning to minimize the overburden and obtain an average grade of maximum ore during first years functionment and economical studies in order to economically evaluate the project in many cases by calculating the internal rate of profit for many uranium sell prices and by utilizing as base investment costs and functioning project reference [fr

  9. Differential regional gray matter volumes in patients with on-line game addiction and professional gamers

    Science.gov (United States)

    Han, Doug Hyun; Lyoo, In Kyoon; Renshaw, Perry F.

    2015-01-01

    Patients with on-line game addiction (POGA) and professional video game players play video games for extended periods of time, but experience very different consequences for their on-line game play. Brain regions consisting of anterior cingulate, thalamus and occpito-temporal areas may increase the likelihood of becoming a pro-gamer or POGA. Twenty POGA, seventeen pro-gamers, and eighteen healthy comparison subjects (HC) were recruited. All magnetic resonance imaging (MRI) was performed on a 1.5 Tesla Espree MRI scanner (SIEMENS, Erlangen, Germany). Voxel-wise comparisons of gray matter volume were performed between the groups using the two-sample t-test with statistical parametric mapping (SPM5). Compared to HC, the POGA group showed increased impulsiveness and perseverative errors, and volume in left thalamus gray matter, but decreased gray matter volume in both inferior temporal gyri, right middle occipital gyrus, and left inferior occipital gyrus, compared with HC. Pro-gamers showed increased gray matter volume in left cingulate gyrus, but decreased gray matter volume in left middle occipital gyrus and right inferior temporal gyrus compared with HC. Additionally, the pro-gamer group showed increased gray matter volume in left cingulate gyrus and decreased left thalamus gray matter volume compared with the POGA group. The current study suggests that increased gray matter volumes of the left cingulate gyrus in pro-gamers and of the left thalamus in POGA may contribute to the different clinical characteristics of pro-gamers and POGA. PMID:22277302

  10. Cerebral gray matter volume in patients with chronic migraine: correlations with clinical features.

    Science.gov (United States)

    Coppola, Gianluca; Petolicchio, Barbara; Di Renzo, Antonio; Tinelli, Emanuele; Di Lorenzo, Cherubino; Parisi, Vincenzo; Serrao, Mariano; Calistri, Valentina; Tardioli, Stefano; Cartocci, Gaia; Ambrosini, Anna; Caramia, Francesca; Di Piero, Vittorio; Pierelli, Francesco

    2017-12-08

    To date, few MRI studies have been performed in patients affected by chronic migraine (CM), especially in those without medication overuse. Here, we performed magnetic resonance imaging (MRI) voxel-based morphometry (VBM) analyses to investigate the gray matter (GM) volume of the whole brain in patients affected by CM. Our aim was to investigate whether fluctuations in the GM volumes were related to the clinical features of CM. Twenty untreated patients with CM without a past medical history of medication overuse underwent 3-Tesla MRI scans and were compared to a group of 20 healthy controls (HCs). We used SPM12 and the CAT12 toolbox to process the MRI data and to perform VBM analyses of the structural T1-weighted MRI scans. The GM volume of patients was compared to that of HCs with various corrected and uncorrected thresholds. To check for possible correlations, patients' clinical features and GM maps were regressed. Initially, we did not find significant differences in the GM volume between patients with CM and HCs (p tablets taken per month. No gross morphometric changes were observed in patients with CM when compared with HCs. However, using more-liberal uncorrected statistical thresholds, we observed that CM is associated with subtle GM volume changes in several brain areas known to be involved in nociception/antinociception, multisensory integration, and analgesic dependence. We speculate that these slight morphometric impairments could lead, at least in a subgroup of patients, to the development and continuation of maladaptive acute medication usage.

  11. Remnant pancreatic parenchymal volume predicts postoperative pancreatic exocrine insufficiency after pancreatectomy.

    Science.gov (United States)

    Okano, Keisuke; Murakami, Yoshiaki; Nakagawa, Naoya; Uemura, Kenichiro; Sudo, Takeshi; Hashimoto, Yasushi; Kondo, Naru; Takahashi, Shinya; Sueda, Taijiro

    2016-03-01

    Pancreatectomy, including pancreatoduodenectomy and distal pancreatectomy, often causes postoperative pancreatic exocrine insufficiency (PEI). Our aim was to clarify a relationship between remnant pancreatic volume and postoperative PEI. A total of 227 patients who underwent pancreatoduodenectomy or distal pancreatectomy were enrolled in this study. All patients underwent a (13)C-labeled mixed triglyceride breath test to assess pancreatic exocrine function and abdominal dynamic computed tomography for assessing remnant pancreatic volume after pancreatectomy at a median of 7 months postoperatively. The percent (13)CO2 cumulative dose at 7 hours (% dose (13)C cum 7 h) pancreatectomy were performed in 174 (76.7%) and 53 (23.3%) patients, respectively. Of the 227 patients, 128 (56.3%) developed postoperative PEI. Postoperative % dose (13)C cum 7 h was strongly correlated with remnant pancreatic volume (r = .509, P pancreatectomy (P pancreatectomy. Remnant pancreatic volume may predict postoperative PEI in patients who undergo pancreatectomy. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Comparative methods for quantifying thyroid volume using planar imaging and SPECT

    International Nuclear Information System (INIS)

    Zaidi, H.

    1996-01-01

    Thyroid volume determination using planar imaging is a procedure often performed in routine nuclear medicine, but is hampered by several physical difficulties, in particular by structures which overlie or underlie the organ of interest. SPECT enables improved accuracy over planar imaging in the determination of the volume since it is derived from the 3-D data rather than from a 2-D projection with a certain geometric assumption regarding the thyroid configuration. By using the phantoms of known volume, it was possible to estimate the accuracy of 3 different methods of determining thyroid volume from planar imaging used in clinical routine. The experimental results demonstrate that compared with conventional scintigraphy, thyroid phantom volumes were most accurately determined with SPECT when attenuation and scatter corrections are performed which allows accurate radiation dosimetry in humans without the need for assumptions on organ size or concentrations. Poster 181. (author)

  13. Molecular representation of molar domain (volume), evolution equations, and linear constitutive relations for volume transport.

    Science.gov (United States)

    Eu, Byung Chan

    2008-09-07

    In the traditional theories of irreversible thermodynamics and fluid mechanics, the specific volume and molar volume have been interchangeably used for pure fluids, but in this work we show that they should be distinguished from each other and given distinctive statistical mechanical representations. In this paper, we present a general formula for the statistical mechanical representation of molecular domain (volume or space) by using the Voronoi volume and its mean value that may be regarded as molar domain (volume) and also the statistical mechanical representation of volume flux. By using their statistical mechanical formulas, the evolution equations of volume transport are derived from the generalized Boltzmann equation of fluids. Approximate solutions of the evolution equations of volume transport provides kinetic theory formulas for the molecular domain, the constitutive equations for molar domain (volume) and volume flux, and the dissipation of energy associated with volume transport. Together with the constitutive equation for the mean velocity of the fluid obtained in a previous paper, the evolution equations for volume transport not only shed a fresh light on, and insight into, irreversible phenomena in fluids but also can be applied to study fluid flow problems in a manner hitherto unavailable in fluid dynamics and irreversible thermodynamics. Their roles in the generalized hydrodynamics will be considered in the sequel.

  14. Radiographic determination of urinary bladder volume and residual urine volume

    International Nuclear Information System (INIS)

    Klumair, J.

    1977-01-01

    In the course of a long study the author has tested most of the methods for determination of urinary bladder volume. A radiographic method which can state bladder volume exactly in cc's is attainable only with great time and effort. In the author's experience, however, it is possible, by means of a pattern in connection with a IVP, to estimate residual urine volume from a post-void picture of the bladder with sufficient accuracy for practical purposes. An account is given of the production of this pattern and of two relatively simple calculations for residual volume based on AP and lateral views of circular- and ellipsoid-shaped bladders. Also discussed is the radiation exposure which varies with the radiographic methods used. In male patients, the radiation exposure appears to be negligible, especially when the testicles are protected by a radiation shield. In female patients - which make up only a small fraction of all patients -, radiation exposure is higher but must be accepted. (orig./MG) [de

  15. Chip-Oriented Fluorimeter Design and Detection System Development for DNA Quantification in Nano-Liter Volumes

    Directory of Open Access Journals (Sweden)

    Da-Sheng Lee

    2009-12-01

    Full Text Available The chip-based polymerase chain reaction (PCR system has been developed in recent years to achieve DNA quantification. Using a microstructure and miniature chip, the volume consumption for a PCR can be reduced to a nano-liter. With high speed cycling and a low reaction volume, the time consumption of one PCR cycle performed on a chip can be reduced. However, most of the presented prototypes employ commercial fluorimeters which are not optimized for fluorescence detection of such a small quantity sample. This limits the performance of DNA quantification, especially low experiment reproducibility. This study discusses the concept of a chip-oriented fluorimeter design. Using the analytical model, the current study analyzes the sensitivity and dynamic range of the fluorimeter to fit the requirements for detecting fluorescence in nano-liter volumes. Through the optimized processes, a real-time PCR on a chip system with only one nano-liter volume test sample is as sensitive as the commercial real-time PCR machine using the sample with twenty micro-liter volumes. The signal to noise (S/N ratio of a chip system for DNA quantification with hepatitis B virus (HBV plasmid samples is 3 dB higher. DNA quantification by the miniature chip shows higher reproducibility compared to the commercial machine with respect to samples of initial concentrations from 103 to 105 copies per reaction.

  16. Relation between injected volume and optical parameters in refilled isolated porcine lenses

    NARCIS (Netherlands)

    Koopmans, SA; Terwee, T; Haitjema, HJ; Deuring, H; van Aarle, S; Kooijman, AC

    2004-01-01

    Purpose: This study was performed to elucidate the correlation between added lens refill material and enhanced lens power as well as the correlation between lens refilling volume and accommodative amplitude as determined by equatorial stretching of ex vivo refilled pigs' lenses. Methods: Nine

  17. Regional differences in brain volume predict the acquisition of skill in a complex real-time strategy videogame.

    Science.gov (United States)

    Basak, Chandramallika; Voss, Michelle W; Erickson, Kirk I; Boot, Walter R; Kramer, Arthur F

    2011-08-01

    Previous studies have found that differences in brain volume among older adults predict performance in laboratory tasks of executive control, memory, and motor learning. In the present study we asked whether regional differences in brain volume as assessed by the application of a voxel-based morphometry technique on high resolution MRI would also be useful in predicting the acquisition of skill in complex tasks, such as strategy-based video games. Twenty older adults were trained for over 20 h to play Rise of Nations, a complex real-time strategy game. These adults showed substantial improvements over the training period in game performance. MRI scans obtained prior to training revealed that the volume of a number of brain regions, which have been previously associated with subsets of the trained skills, predicted a substantial amount of variance in learning on the complex game. Thus, regional differences in brain volume can predict learning in complex tasks that entail the use of a variety of perceptual, cognitive and motor processes. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Effect of Thyroid Remnant Volume on the Risk of Hypothyroidism After Hemithyroidectomy: A Prospective Study.

    Science.gov (United States)

    Lang, Brian Hung-Hin; Wong, Carlos K H; Wong, Kai Pun; Chu, Kelvin Ka-Wan; Shek, Tony W H

    2017-06-01

    Hypothyroidism is a common sequel after a hemithyroidectomy. Although various risk factors leading to hypothyroidism have been reported, the effect of the contralateral lobe's volume has been understudied. This study aimed to examine the association between the preoperative contralateral lobe's volume and the risk of postoperative hypothyroidism. During a 2-year period, 150 eligible patients undergoing a hemithyroidectomy were evaluated. The volume of the contralateral nonexcised lobe was estimated preoperatively by independent assessors on ultrasonography using the following formula: width (in cm) × depth (in cm) × length (in cm) × (π/6), adjusted for the body surface area (BSA). Postoperative hypothyroidism was defined as serum thyroid-stimulating hormone (TSH) exceeding 4.78 mIU/L. Any significant characteristics in the univariate analysis were entered into the multivariate analysis to determine independent factors. After a mean follow-up period of 53.5 ± 9.4 months, 44 patients (29.3 %) experienced postoperative hypothyroidism, and 10 of these patients required thyroxine replacement. Hypothyroidism was associated with a higher preoperative TSH level (p hypothyroidism. Patients with a BSA-adjusted volume smaller than 3.2 ml had a threefold greater hypothyroidism risk than those with a BSA-adjusted volume of 3.2 ml or more (p hypothyroidism risk was observed after hemithyroidectomy. Together with a higher preoperative TSH level and fewer ipsilateral nodules, a smaller BSA-adjusted volume measured by preoperative ultrasonography independently predicted hypothyroidism.

  19. Mechanical Properties and Shear Strengthening Capacity of High Volume Fly Ash-Cementitious Composite

    Science.gov (United States)

    Joseph, Aswin K.; Anand, K. B.

    2018-02-01

    This paper discusses development of Poly Vinyl Alcohol (PVA) fibre reinforced cementitious composites taking into account environmental sustainability. Composites with fly ash to cement ratios from 0 to 3 are investigated in this study. The mechanical properties of HVFA-cement composite are discussed in this paper at PVA fiber volume fraction maintained at 1% of total volume of composite. The optimum replacement of cement with fly ash was found to be 75%, i.e. fly ash to cement ratio (FA/C) of 3. The increase in fiber content from 1% to 2% showed better mechanical performance. A strain capacity of 2.38% was obtained for FA/C ratio of 3 with 2% volume fraction of fiber. With the objective of evaluating the performance of cementitious composites as a strengthening material in reinforced concrete beams, the beams deficient in shear capacity were strengthened with optimal mix having 2% volume fraction of fiber as the strengthening material and tested under four-point load. The reinforced concrete beams designed as shear deficient were loaded to failure and retrofitted with the composite in order to assess the efficiency as a repair material under shear.

  20. Cone-beam volume CT mammographic imaging: feasibility study

    Science.gov (United States)

    Chen, Biao; Ning, Ruola

    2001-06-01

    X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.