WorldWideScience

Sample records for performance standards apply

  1. The improvement of environmental performances by applying ISO 14001 standard: A case study

    Directory of Open Access Journals (Sweden)

    Živković Snežana

    2013-01-01

    Full Text Available This paper presents the analysis of the advantages of applying ISO 14001 system in an environmental protection management system. The environmental protection management system which is not licensed, i.e., compatible with the principles and standard pre-conditions considerably increases the plausibility for ecological risk. There are some issues that remain to be solved in the areas which are not expressed by financial values only but also have a non-financial character with the aim of expanding markets, company image improvement and improvement of the environmental performance indicators. By improving a company’s environmental management system efficiency we expect to achieve the minimization and elimination of damaging influences on the environment which are the consequence of company’s activities. A case study in the Oil Refinery Belgrade (RNB analyses the implementation of the standard ISO 14001:2004 into its environment protection management system, particularly emphasizing the company’s own way of evaluating the environment aspects with the aim of establishing results of ecological performances indicators improvement. The average values of the first ecological indicator of the plant, the total amount of the waste waters in m3 per a ton of product, clearly show the downturn trend, which is confirmed by the proportional reduction of the second ecological plant indicator, that is by the flocculants consumption (Al2(SO43, Na2CO3 in kg per m3 of the waste water of the Oil Refinery of Belgrade for the given period 2008-2010. Case study RNB confirms the improvement of environmental performances using the ISO 14001 standard.

  2. 40 CFR 60.1025 - Do subpart E new source performance standards also apply to my municipal waste combustion unit?

    Science.gov (United States)

    2010-07-01

    ... standards also apply to my municipal waste combustion unit? 60.1025 Section 60.1025 Protection of... NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for Which... municipal waste combustion unit? If this subpart AAAA applies to your municipal waste combustion unit, then...

  3. 20 CFR 669.500 - What performance measures and standards apply to the NFJP?

    Science.gov (United States)

    2010-04-01

    ... account the characteristics of the population to be served and the economic conditions in the service area... must be included in the approved plan. (b) We may develop additional performance indicators with... service area economy and local demographics of eligible MSFW's. The levels of performance for these...

  4. Standards for Lithotripter Performance

    Science.gov (United States)

    Schultheiss, Reiner; Doerffel, Michael

    2008-09-01

    Standards for lithotripsy have been developed by the International Electrotechnical Commission (IEC) and the FDA. In addition to the existing regulations and norms for the manufacturers, special standards were developed to address a treatment method developed in the early 1980's using extracorporeal shock waves. Initially, the FDA regulated the premarket approval process for lithotripters as a Class III device but reclassified lithotripters in 2000 to a Class II device. The corresponding guidance document for showing the substantial equivalence of new devices with predicate devices will be described in detail. The FDA guidance document is very useful in helping device manufacturers: (i) develop technical performance testing for a shock wave lithotripter within the parameters of an FDA submission, and (ii) conduct clinical performance testing via at least one clinical confirmation study with a small number of subjects. Unfortunately although the submitted data are available at the FDA they are not available in the marketplace and this causes difficulties for physicians in deciding which device to use. The results of the technical performance testing of the LithoGold™ are provided.

  5. Performance standard for dose Calibrator

    CERN Document Server

    Darmawati, S

    2002-01-01

    Dose calibrator is an instrument used in hospitals to determine the activity of radionuclide for nuclear medicine purposes. International Electrotechnical Commission (IEC) has published IEC 1303:1994 standard that can be used as guidance to test the performance of the instrument. This paper briefly describes content of the document,as well as explains the assessment that had been carried out to test the instrument accuracy in Indonesia through intercomparison measurement.Its is suggested that hospitals acquire a medical physicist to perform the test for its dose calibrator. The need for performance standard in the form of Indonesia Standard is also touched.

  6. Applying consensus standards to cask development

    International Nuclear Information System (INIS)

    Leatham, J.; Abbott, D.G.; Warrant, M.M.

    1987-01-01

    The Department of Energy's (DOE's) Office of Civilian Radioactive Waste Management is procuring cask systems for transporting commercial spent nuclear fuel and is encouraging development of innovative cask designs and materials to improve system efficiency. New designs and innovative materials require that consensus standards be established so that cask designers and regulators have criteria for determining acceptability. Recent DOE experience in certifying three spent fuel shipping casks, NUPAC-125B, TN-BRP, and TN-REG, is discussed. Certification of the NUPAC-125B was expedited because it was made of conventional American Society for Testing and Materials (ASTM) materials and complied with the American Society of Mechanical Engineers (ASME) Code and Nuclear Regulatory Commission Regulatory Guides. The TN-BRP and TN-REG cask designs are still being reviewed because baskets included in the casks are made of borated stainless steel, which has no ASTM Specification or ASME Code approval. The process of developing and approving consensus standards is discussed, including the role of ANSI and ANSI N14. Specific procedures for ASTM and ASME are described. A draft specification or standard must be prepared and then approved by the appropriate body. For new material applications to the ASME Code, an existing ASTM Specification is needed. These processes may require several years. The status of activities currently in progress to develop consensus standards for spent fuel casks is discussed, including (1) ASME NUPAC, and (2) ASTM Specifications for ductile cast iron and borated stainless steel

  7. Rethinking Game Based Learning: applying pedagogical standards to educational games

    NARCIS (Netherlands)

    Schmitz, Birgit; Kelle, Sebastian

    2010-01-01

    Schmitz, B., & Kelle, S. (2010, 1-6 February). Rethinking Game Based Learning: applying pedagogical standards to educational games. Presentation at JTEL Winter School 2010 on Advanced Learning Technologies, Innsbruck, Austria.

  8. Interdisciplinary strate in applied performance and activism

    OpenAIRE

    Johansson, Ola

    2014-01-01

    The paper addresses the challenges and advantages of collaborative stratification in the continuum of theatre and fine arts, with examples from applied performance projects in international contexts. With different approaches to performance/media, acting/agency, devising/curatorship and participation/social engagement, collaborative processes have proved to be quite incongruent in method and motif, although inclusive and versatile in media tactics and political outreach. In post-Brechtian the...

  9. European standards applied by Gas Transmission System Operator

    International Nuclear Information System (INIS)

    Witek, M.; Kuchta, K.; Oleszkiewicz, J.; Teperek, T.

    2005-01-01

    The lecture described actual state of implementation of European standards concerning transmission of natural gas and underlined their importance for proper performance of Transmission System Operator (TSO). European standards implemented to Polish Standards as PN-EN, necessary for TSO, related to design, construction and operation of high pressure gas network were also described. The lecture underlined as well the impact of standards application on preparation process of national regulations. They obligate TSO to create the technical conditions that ensure safety of gas transmission network functioning as well as environmental and surroundings safety. (authors)

  10. Exponential models applied to automated processing of radioimmunoassay standard curves

    International Nuclear Information System (INIS)

    Morin, J.F.; Savina, A.; Caroff, J.; Miossec, J.; Legendre, J.M.; Jacolot, G.; Morin, P.P.

    1979-01-01

    An improved computer processing is described for fitting of radio-immunological standard curves by means of an exponential model on a desk-top calculator. This method has been applied to a variety of radioassays and the results are in accordance with those obtained by more sophisticated models [fr

  11. Performance Monitoring Applied to System Supervision

    Directory of Open Access Journals (Sweden)

    Bertille Somon

    2017-07-01

    Full Text Available Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL performance problem.

  12. 77 FR 56421 - Standards of Performance for Petroleum Refineries; Standards of Performance for Petroleum...

    Science.gov (United States)

    2012-09-12

    ... Parts 9 and 60 Standards of Performance for Petroleum Refineries; Standards of Performance for Petroleum...-9672-3] RIN 2060-AN72 Standards of Performance for Petroleum Refineries; Standards of Performance for Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After May 14, 2007...

  13. Nuclear performance standards: Promoting efficient generation

    International Nuclear Information System (INIS)

    Nagelhout, M.

    1990-01-01

    Nuclear plant performance standards are designed to share the risks of operation associated with nuclear generation. Such standards often shift risks from ratepayers to utility shareholders, even without a finding of imprudence or mismanagement. The rationale underlying nuclear performance standards is that ratepayers should not be responsible for excessive replacement power costs incurred as a result of unreasonable decisions by utility management, especially because the high fixed costs of nuclear plants are already included in base rates. In addition, performance standards can be designed to provide incentives to reward utilities that achieve superior nuclear performance, for the benefit of both ratepayers and shareholders

  14. Performance Standards for Windows | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  15. Intelligence Level Performance Standards Research for Autonomous Vehicles.

    Science.gov (United States)

    Bostelman, Roger B; Hong, Tsai H; Messina, Elena

    2015-01-01

    United States and European safety standards have evolved to protect workers near Automatic Guided Vehicles (AGV's). However, performance standards for AGV's and mobile robots have only recently begun development. Lessons can be learned from research and standards efforts for mobile robots applied to emergency response and military applications. Research challenges, tests and evaluations, and programs to develop higher intelligence levels for vehicles can also used to guide industrial AGV developments towards more adaptable and intelligent systems. These other efforts also provide useful standards development criteria for AGV performance test methods. Current standards areas being considered for AGVs are for docking, navigation, obstacle avoidance, and the ground truth systems that measure performance. This paper provides a look to the future with standards developments in both the performance of vehicles and the dynamic perception systems that measure intelligent vehicle performance.

  16. Applying and extending ISO/TC42 digital camera resolution standards to mobile imaging products

    Science.gov (United States)

    Williams, Don; Burns, Peter D.

    2007-01-01

    There are no fundamental differences between today's mobile telephone cameras and consumer digital still cameras that suggest many existing ISO imaging performance standards do not apply. To the extent that they have lenses, color filter arrays, detectors, apertures, image processing, and are hand held, there really are no operational or architectural differences. Despite this, there are currently differences in the levels of imaging performance. These are driven by physical and economic constraints, and image-capture conditions. Several ISO standards for resolution, well established for digital consumer digital cameras, require care when applied to the current generation of cell phone cameras. In particular, accommodation of optical flare, shading non-uniformity and distortion are recommended. We offer proposals for the application of existing ISO imaging resolution performance standards to mobile imaging products, and suggestions for extending performance standards to the characteristic behavior of camera phones.

  17. Performance standards of road safety management

    Directory of Open Access Journals (Sweden)

    Čabarkapa Milenko R.

    2016-01-01

    Full Text Available Road safety management controlling means the process of finding out the information whether the road safety is improving in a measure to achieve the objectives. The process of control consists of three basic elements: definition of performances and standards, measurement of current performances and comparison with the set standards, and improvement of current performances, if they deviate from the set standards. The performance standards of road safety management system are focused on a performances measurement, in terms of their design and characteristics, in order to support the performances improvement of road safety system and thus, ultimately, improve the road safety. Defining the performance standards of road safety management system, except that determines the design of the system for performances measurement, directly sets requirements whose fulfillment will produce a road safety improvement. The road safety management system, based on the performance standards of road safety, with a focus on results, will produce the continuous improvement of road safety, achieving the long-term 'vision zero', the philosophy of road safety, that human life and health take priority over mobility and other traffic objectives of the road traffic.

  18. Applying Standards for Leaders to the Selection of Secondary School Principals

    Science.gov (United States)

    Wildy, Helen; Pepper, Coral; Guanzhong, Luo

    2011-01-01

    Purpose: The purpose of this paper is to report innovative research aimed at ascertaining whether standards for school leaders could be applied to the process of selecting senior secondary school principals for appointment. Specifically, psychometrically robust measures of performance are sought that would sufficiently differentiate performance to…

  19. Business School's Performance Management System Standards Design

    Science.gov (United States)

    Azis, Anton Mulyono; Simatupang, Togar M.; Wibisono, Dermawan; Basri, Mursyid Hasan

    2014-01-01

    This paper aims to compare various Performance Management Systems (PMS) for business school in order to find the strengths of each standard as inputs to design new model of PMS. There are many critical aspects and gaps notified for new model to improve performance and even recognized that self evaluation performance management is not well…

  20. Grain Elevators: New Source Performance Standards (NSPS)

    Science.gov (United States)

    The New Source Performance Standards (NSPS) for Grain Elevators aims to reduce particulate matter pollution. The new amendments seek to clarify definitions, and requirements, as well as propose new regulations on particulate matter emissions

  1. 24 CFR 115.206 - Performance assessments; Performance standards.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Performance assessments; Performance standards. 115.206 Section 115.206 Housing and Urban Development Regulations Relating to Housing... AGENCIES Certification of Substantially Equivalent Agencies § 115.206 Performance assessments; Performance...

  2. Motivational Implications of Faculty Performance Standards

    Science.gov (United States)

    Hardre, Patricia L.; Kollmann, Sherry L.

    2012-01-01

    Expectations and how they are communicated influence employees' motivation, effort, goals, efficacy and performance. This study examined faculty performance evaluation standards and processes of 60 academic departments in research universities for motivationally relevant elements. Characteristics were systematically analysed to understand their…

  3. Federal Procurement Standards Applied to School Food Services.

    Science.gov (United States)

    VanEgmond-Pannell, Dorothy

    1984-01-01

    Explains standards laid out in Federal Circular A-120 to ensure accountability, uniformity of standards, legal compliance, and efficiency in school food service procurement. Includes bidding and contract award procedures, contract compliance considerations, and cost-cutting methods. (MCG)

  4. Lightening protection, techniques, applied codes and standards. Vol. 4

    International Nuclear Information System (INIS)

    Mahmoud, M.; Shaaban, H.; Lamey, S.

    1996-01-01

    Lightening is the only natural disaster that protection against is highly effective. Therefore for the safety of critical installations specifically nuclear, an effective lightening protection system (LPS) is required. The design and installation of LPS's have been addressed by many international codes and standards. In this paper, the various LPS's are discussed and compared, including radioactive air terminals, ionizing air terminals, and terminals equipped with electrical trigging devices. Also, the so-called dissipation array systems are discussed and compared to other systems technically and economically. Moreover, the available international codes and standards related to the lightening protection are discussed. such standards include those published by the national fire protection association (NFPA), lightening protection institute (LPI), underwriters laboratories (UL), and british standards Finally, the possibility of developing an egyptian national standards is discussed

  5. Hearing protector performance and standard deviation.

    Science.gov (United States)

    Williams, W; Dillon, H

    2005-01-01

    The attenuation performance of a hearing protector is used to estimate the protected exposure level of the user. The aim is to reduce the exposed level to an acceptable value. Users should expect the attenuation to fall within a reasonable range of values around a norm. However, an analysis of extensive test data indicates that there is a negative relationship between attenuation performance and the standard deviation. This result is deduced using a variation in the method of calculating a single number rating of attenuation that is more amenable to drawing statistical inferences. As performance is typically specified as a function of the mean attenuation minus one or two standard deviations from the mean to ensure that greater than 50% of the wearer population are well protected, the implication of increasing standard deviation with decreasing attenuation found in this study means that a significant number of users are, in fact, experiencing over-protection. These users may be disinclined to use their hearing protectors because of an increased feeling of acoustic isolation. This problem is exacerbated in areas with lower noise levels.

  6. Understanding Grades and Standards: and how to apply them

    OpenAIRE

    Giovannucci, Daniele; Reardon, Thomas

    2000-01-01

    With the expanding globalization of trade, grades and standards help to set the ‘rules of the game’ and their implications for developing countries are becoming increasingly relevant. While they are clearly important to trade, their formation and utilization is also undergoing a shift from being neutral market lubricants to also being tools of product differentiation. This implies a fundamental shift in the role of standards from just reducing transaction costs of commodity market particip...

  7. Standard specification for agencies performing nondestructive testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This specification covers minimum requirements for agencies performing nondestructive testing (NDT). 1.2 When using this specification to assess the capability of, or to accredit NDT agencies, Guide E 1359 shall be used as a basis for the survey. It can be supplemented as necessary with more detail in order to meet the auditor's specific needs. 1.3 This specification can be used as a basis to evaluate testing or inspection agencies, or both, and is intended for use for the qualifying or accrediting, or both, of testing or inspection agencies, public or private. 1.4 The use of SI or inch-pound units, or combination thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to...

  8. 25 CFR 900.49 - What procurement standards apply to subcontracts?

    Science.gov (United States)

    2010-04-01

    ... ASSISTANCE ACT Standards for Tribal or Tribal Organization Management Systems Procurement Management System Standards § 900.49 What procurement standards apply to subcontracts? Each subcontract entered into under the... 25 Indians 2 2010-04-01 2010-04-01 false What procurement standards apply to subcontracts? 900.49...

  9. 77 FR 52553 - Standards of Performance for Stationary Gas Turbines; Standards of Performance for Stationary...

    Science.gov (United States)

    2012-08-29

    ... still perform the traditional reconstruction analysis, i.e., the owner/operator would compare the total... blending to achieve the applicable SO 2 standard. Under the proposed language, an owner/operator of an...

  10. Applying Standard Industrial Components for Active Magnetic Bearings

    Directory of Open Access Journals (Sweden)

    Bert-Uwe Koehler

    2017-02-01

    Full Text Available With the increasing number of active magnetic bearing applications, satisfying additional requirements is becoming increasingly more important. As for every technology, moving away from being a niche product and achieving a higher level of maturity, these requirements relate to robustness, reliability, availability, safety, security, traceability, certification, handling, flexibility, reporting, costs, and delivery times. Employing standard industrial components, such as those from flexible modular motion control drive systems, is an approach that allows these requirements to be satisfied while achieving rapid technological innovation. In this article, we discuss technical and non-technical aspects of using standard industrial components in magnetic bearing applications.

  11. 32 CFR 1656.11 - Job performance standards and sanctions.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Job performance standards and sanctions. 1656.11... ALTERNATIVE SERVICE § 1656.11 Job performance standards and sanctions. (a) Standards of Performance. An ASW is..., appearance or performance violates reasonable employer standards; or (4) He quits or leaves his job without...

  12. EUROPE AND GLOBALIZATION: FRAMEWORK FOR APPLYING DOUBLE-STANDARDS

    Directory of Open Access Journals (Sweden)

    Rada Cristina IRIMIE

    2014-11-01

    Full Text Available The term of “globalization” has been very much used in recent days in order to explain a series of phenomena, especially from the economic field. Indeed, after a thorough research, globalization could be mostly relegated to the economic field. However, the term can also designate a series of other processes, from other fields of activities. The present paper shall deal with an analysis of two economic colossus – the European Union and China by applying to them the variable of “globalization”. It is globalization that made possible the establishment of such relations, as well as their effective management and constant improvement. Even if the relations have had their ups and downs, the general framework provided by globalization helped appease conflicts when they were about to break out, and even offered an alternative to situations which seemed impossible to manage (as is the arms embargo. The paper shall be structured as follows: an analysis of the term from several perspectives, including the social and economic one, followed by its application to the given situation: the European Union-Chinese relations. In this regard, given time and space constraints, we shall limit the research to only two types of cooperation: economic and political and security-related cooperation. The final chapter of the paper shall also refer to several elements of discontent within this relation, such as the arms embargo, the disrespect for human rights in China and the unstable situation of Taiwan. However, these elements of discontent shall only be referred to when necessary, leaving a deeper analysis of them to a future academic endeavor.

  13. 40 CFR 415.115 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY Potassium Metal Production... achieve the following new source performance standards (NSPS): There shall be no discharge of process...

  14. Load carriage, human performance, and employment standards.

    Science.gov (United States)

    Taylor, Nigel A S; Peoples, Gregory E; Petersen, Stewart R

    2016-06-01

    The focus of this review is on the physiological considerations necessary for developing employment standards within occupations that have a heavy reliance on load carriage. Employees within military, fire fighting, law enforcement, and search and rescue occupations regularly work with heavy loads. For example, soldiers often carry loads >50 kg, whilst structural firefighters wear 20-25 kg of protective clothing and equipment, in addition to carrying external loads. It has long been known that heavy loads modify gait, mobility, metabolic rate, and efficiency, while concurrently elevating the risk of muscle fatigue and injury. In addition, load carriage often occurs within environmentally stressful conditions, with protective ensembles adding to the thermal burden of the workplace. Indeed, physiological strain relates not just to the mass and dimensions of carried objects, but to how those loads are positioned on and around the body. Yet heavy loads must be borne by men and women of varying body size, and with the expectation that operational capability will not be impinged. This presents a recruitment conundrum. How do employers identify capable and injury-resistant individuals while simultaneously avoiding discriminatory selection practices? In this communication, the relevant metabolic, cardiopulmonary, and thermoregulatory consequences of loaded work are reviewed, along with concomitant impediments to physical endurance and mobility. Also emphasised is the importance of including occupation-specific clothing, protective equipment, and loads during work-performance testing. Finally, recommendations are presented for how to address these issues when evaluating readiness for duty.

  15. 12 CFR 345.26 - Small bank performance standards.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Small bank performance standards. 345.26... GENERAL POLICY COMMUNITY REINVESTMENT Standards for Assessing Performance § 345.26 Small bank performance standards. (a) Performance criteria—(1) Small banks that are not intermediate small banks. The FDIC...

  16. Standardization of Nuclear Instrumentation Applied in the NPP and in other nuclear installations

    International Nuclear Information System (INIS)

    Kusnowo, Arlinah; Darmawati, Suzie

    2002-01-01

    Nuclear power plant (NPP) and other nuclear installations have been recognized as applications needing very sophisticated technologies. One of technologies used in this all nuclear facilities is nuclear instrumentation. In order that NPP and other nuclear installations be operated safely, nuclear instrumentation requires standardization from design to its operation. Internationally, standardizations of nuclear instrumentation have been issued by IEC (International Electrotechnical Commission). Formulation of standard in nuclear instrumentation in IEC is carried out by Technical Committee (TC) 45. This paper describes briefly the standardization of nuclear instrumentation applied in Indonesia as Indonesian National Standard (SNI, Standard National Indonesia), standardization of nuclear instrumentation developed by TC 45, SC 45A, and SC 45B, as well as the possibility to adopt and apply those IEC standard in Indonesia

  17. Recommendations for Autonomous Industrial Vehicle Performance Standards

    OpenAIRE

    Bostelman , Roger

    2016-01-01

    International audience; A workshop was held at the IEEE International Conference on Robotics and Automation, called: “Autonomous Industrial Vehicles: From the Laboratory to the Factory Floor”. Nine research papers were presented followed by a discussion session summarized in this paper. The workshop findings are intended to be useful for developing standards within the ASTM F45 Committee for Driverless Automatic Industrial Vehicles. This paper provides feedback from the discussion listing the...

  18. 12 CFR 228.26 - Small bank performance standards.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Small bank performance standards. 228.26... bank performance standards. (a) Performance criteria—(1) Small banks that are not intermediate small... performance is evaluated pursuant to the following criteria: (1) The bank's loan-to-deposit ratio, adjusted...

  19. 12 CFR 25.26 - Small bank performance standards.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Small bank performance standards. 25.26 Section... § 25.26 Small bank performance standards. (a) Performance criteria—(1) Small banks that are not... lending performance is evaluated pursuant to the following criteria: (1) The bank's loan-to-deposit ratio...

  20. 40 CFR 415.645 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY Cadmium Pigments and Salts Production Subcategory § 415.645 New source performance standards (NSPS). (a) Any new source subject to this subpart and producing cadmium pigments must achieve the following new source performance standards (NSPS...

  1. 47 CFR 25.209 - Antenna performance standards.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Antenna performance standards. 25.209 Section 25.209 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Standards § 25.209 Antenna performance standards. (a) The gain of any...

  2. ASDTIC control and standardized interface circuits applied to buck, parallel and buck-boost dc to dc power converters

    Science.gov (United States)

    Schoenfeld, A. D.; Yu, Y.

    1973-01-01

    Versatile standardized pulse modulation nondissipatively regulated control signal processing circuits were applied to three most commonly used dc to dc power converter configurations: (1) the series switching buck-regulator, (2) the pulse modulated parallel inverter, and (3) the buck-boost converter. The unique control concept and the commonality of control functions for all switching regulators have resulted in improved static and dynamic performance and control circuit standardization. New power-circuit technology was also applied to enhance reliability and to achieve optimum weight and efficiency.

  3. Performance Standards': Utility for Different Uses of Assessments

    Directory of Open Access Journals (Sweden)

    Robert L. Linn

    2003-09-01

    Full Text Available Performance standards are arguably one of the most controversial topics in educational measurement. There are uses of assessments such as licensure and certification where performance standards are essential. There are many other uses, however, where performance standards have been mandated or become the preferred method of reporting assessment results where the standards are not essential to the use. Distinctions between essential and nonessential uses of performance standards are discussed. It is argued that the insistence on reporting in terms of performance standards in situations where they are not essential has been more harmful than helpful. Variability in the definitions of proficient academic achievement by states for purposes of the No Child Left Behind Act of 2001 is discussed and it is argued that the variability is so great that characterizing achievement is meaningless. Illustrations of the great uncertainty in standards are provided.

  4. 47 CFR 80.1101 - Performance standards.

    Science.gov (United States)

    2010-10-01

    ... radiocommunication equipment and systems—General requirements—Methods of testing and required test results,” Edition... Equipment—Keyboard Layouts for Numeric Applications,” First Edition 1976(E). (c) The equipment specified in... Inmarsat system—operational and performance requirements, methods of testing and required test results...

  5. Fulfillment of GMP standard, halal standard, and applying HACCP for production process of beef floss (Case study: Ksatria enterprise)

    Science.gov (United States)

    A'diat, Arkan Addien Al; Liquiddanu, Eko; Laksono, Pringgo Widyo; Sutopo, Wahyudi; Suletra, I. Wayan

    2018-02-01

    Along with the increasing number of the modern retail business in Indonesia, give an opportunity to small and medium enterprise (SME) to sell its products through the modern retailer. There are some obstacles faced by the SMEs, one of them is about product standard. Product standard that must be owned by SMEs are GMP standard and halal standard. This research was conducted to know the fulfillment by the beef floss enterprise in jagalan in fulfilling the GMP standard and halal. In addition, Hazard Analysis and Critical Control Points (HACCP) system was applied to analyze the process. HACCP which used in this research was based on the seven principles in SNI (Indonesian National Standard) 01-4852-1998. The seven principles included hazard analysis, critical control point (CCP) determination, critical limit establishment, CCP monitor system establishment, corrective action establishment, verification, and also documentation establishment that must be applied in preparing HACCP plan. Based on this case study, it is concluded that there were 5 CCPs : the boiling process, roasting process, frying process, the beef floss draining process, and the packaging process.

  6. 40 CFR 267.171 - What standards apply to the containers?

    Science.gov (United States)

    2010-07-01

    ... STANDARDIZED PERMIT Use and Management of Containers § 267.171 What standards apply to the containers... to the management of the containers. (a) Condition of containers. If a container holding hazardous... that are compatible and will not react with the hazardous waste to be stored. (c) Management of...

  7. 12 CFR 563e.26 - Small savings association performance standards.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Small savings association performance standards. 563e.26 Section 563e.26 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY COMMUNITY REINVESTMENT Standards for Assessing Performance § 563e.26 Small savings association performance...

  8. 33 CFR 332.5 - Ecological performance standards.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Ecological performance standards..., DEPARTMENT OF DEFENSE COMPENSATORY MITIGATION FOR LOSSES OF AQUATIC RESOURCES § 332.5 Ecological performance... objective and verifiable. Ecological performance standards must be based on the best available science that...

  9. Swimming and other activities: applied aspects of fish swimming performance

    Science.gov (United States)

    Castro-Santos, Theodore R.; Farrell, A.P.

    2011-01-01

    Human activities such as hydropower development, water withdrawals, and commercial fisheries often put fish species at risk. Engineered solutions designed to protect species or their life stages are frequently based on assumptions about swimming performance and behaviors. In many cases, however, the appropriate data to support these designs are either unavailable or misapplied. This article provides an overview of the state of knowledge of fish swimming performance – where the data come from and how they are applied – identifying both gaps in knowledge and common errors in application, with guidance on how to avoid repeating mistakes, as well as suggestions for further study.

  10. 10 CFR 435.4 - Energy efficiency performance standard.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Energy efficiency performance standard. 435.4 Section 435.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential...

  11. A comparative study of performance measurement standards of railway operator

    Directory of Open Access Journals (Sweden)

    Pongjirawut Siripong

    2017-01-01

    Full Text Available The European standard (EN 13816, is one of the widely accepted standards for measuring the quality of public passenger transport (PPT service. EN 13816 indicates 8 measurement criteria, 29 sub-criteria and 193 Key Performance Indicators (KPIs to be used to measure the performance of railway operators. Nowadays, there are other addition criteria beyond EN13816, developed by various organisations. This research firstly aims to explore the service performance measurement of railway operators used by actual railway operators at international level and in Thailand. After an intensive review of performance measurement standards, 9 standards are compiled and compared in terms of criteria, sub-criteria and KPIs using a cluster analysis methodology. The result found additional performance measurement aspects at 2 sub-criteria and 91 KPIs in addition to EN 13816. This research summarized and compared different performance measurement standards to measure service quality of metro rail line.

  12. 20 CFR 404.1643 - Performance accuracy standard.

    Science.gov (United States)

    2010-04-01

    ... DISABILITY INSURANCE (1950- ) Determinations of Disability Performance Standards § 404.1643 Performance... have been in the file but was not included, even though its inclusion does not change the result in the...

  13. Comparison of the Standards applied to Instrumentation and Control Systems for Nuclear Power Stations in Korea and Russia

    International Nuclear Information System (INIS)

    Park, Joo Hyun; Hwang, In Koo; Lee, Dong Young

    2005-04-01

    This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian standards however provide only conceptual definitions and requirements in the seismic related aspects. Therefore, it is conceived that any equipment or system qualified seismically in accordance with Korean standards should additionally provide technical evidence that it is satisfactory with Russian standards as well. In electromagnetic interference qualification, because Russian standard requires more testing items than the current Korean standard, the additional qualification tests are necessary to meet the Russian requirements. However, these additional test items are based on IEC(International Electrotechnical Commission), therefore it is not a problem to perform those tests in a Korean testing facility

  14. Comparison of the Standards applied to Instrumentation and Control Systems for Nuclear Power Stations in Korea and Russia

    Energy Technology Data Exchange (ETDEWEB)

    Park, Joo Hyun; Hwang, In Koo; Lee, Dong Young

    2005-04-15

    This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian standards however provide only conceptual definitions and requirements in the seismic related aspects. Therefore, it is conceived that any equipment or system qualified seismically in accordance with Korean standards should additionally provide technical evidence that it is satisfactory with Russian standards as well. In electromagnetic interference qualification, because Russian standard requires more testing items than the current Korean standard, the additional qualification tests are necessary to meet the Russian requirements. However, these additional test items are based on IEC(International Electrotechnical Commission), therefore it is not a problem to perform those tests in a Korean testing facility.

  15. Experience with local lymph node assay performance standards using standard radioactivity and nonradioactive cell count measurements.

    Science.gov (United States)

    Basketter, David; Kolle, Susanne N; Schrage, Arnhild; Honarvar, Naveed; Gamer, Armin O; van Ravenzwaay, Bennard; Landsiedel, Robert

    2012-08-01

    The local lymph node assay (LLNA) is the preferred test for identification of skin-sensitizing substances by measuring radioactive thymidine incorporation into the lymph node. To facilitate acceptance of nonradioactive variants, validation authorities have published harmonized minimum performance standards (PS) that the alternative endpoint assay must meet. In the present work, these standards were applied to a variant of the LLNA based on lymph node cell counts (LNCC) run in parallel as a control with the standard LLNA with radioactivity measurements, with threshold concentrations (EC3) being determined for the sensitizers. Of the 22 PS chemicals tested in this study, 21 yielded the same results from standard radioactivity and cell count measurements; only 2-mercaptobenzothiazole was positive by LLNA but negative by LNCC. Of the 16 PS positives, 15 were positive by LLNA and 14 by LNCC; methylmethacrylate was not identified as sensitizer by either of the measurements. Two of the six PS negatives tested negative in our study by both LLNA and LNCC. Of the four PS negatives which were positive in our study, chlorobenzene and methyl salicylate were tested at higher concentrations than the published PS, whereas the corresponding concentrations resulted in consistent negative results. Methylmethacrylate and nickel chloride tested positive within the concentration range used for the published PS. The results indicate cell counts and radioactive measurements are in good accordance within the same LLNA using the 22 PS test substances. Comparisons with the published PS results may, however, require balanced analysis rather than a simple checklist approach. Copyright © 2011 John Wiley & Sons, Ltd.

  16. Standardized assessment of infrared thermographic fever screening system performance

    Science.gov (United States)

    Ghassemi, Pejhman; Pfefer, Joshua; Casamento, Jon; Wang, Quanzeng

    2017-03-01

    Thermal modalities represent the only currently viable mass fever screening approach for outbreaks of infectious disease pandemics such as Ebola and SARS. Non-contact infrared thermometers (NCITs) and infrared thermographs (IRTs) have been previously used for mass fever screening in transportation hubs such as airports to reduce the spread of disease. While NCITs remain a more popular choice for fever screening in the field and at fixed locations, there has been increasing evidence in the literature that IRTs can provide greater accuracy in estimating core body temperature if appropriate measurement practices are applied - including the use of technically suitable thermographs. Therefore, the purpose of this study was to develop a battery of evaluation test methods for standardized, objective and quantitative assessment of thermograph performance characteristics critical to assessing suitability for clinical use. These factors include stability, drift, uniformity, minimum resolvable temperature difference, and accuracy. Two commercial IRT models were characterized. An external temperature reference source with high temperature accuracy was utilized as part of the screening thermograph. Results showed that both IRTs are relatively accurate and stable (<1% error of reading with stability of +/-0.05°C). Overall, results of this study may facilitate development of standardized consensus test methods to enable consistent and accurate use of IRTs for fever screening.

  17. Applying open source data visualization tools to standard based medical data.

    Science.gov (United States)

    Kopanitsa, Georgy; Taranik, Maxim

    2014-01-01

    Presentation of medical data in personal health records (PHRs) requires flexible platform independent tools to ensure easy access to the information. Different backgrounds of the patients, especially elder people require simple graphical presentation of the data. Data in PHRs can be collected from heterogeneous sources. Application of standard based medical data allows development of generic visualization methods. Focusing on the deployment of Open Source Tools, in this paper we applied Java Script libraries to create data presentations for standard based medical data.

  18. Standards and reliability in evaluation: when rules of thumb don't apply.

    Science.gov (United States)

    Norcini, J J

    1999-10-01

    The purpose of this paper is to identify situations in which two rules of thumb in evaluation do not apply. The first rule is that all standards should be absolute. When selection decisions are being made or when classroom tests are given, however, relative standards may be better. The second rule of thumb is that every test should have a reliability of .80 or better. Depending on the circumstances, though, the standard error of measurement, the consistency of pass/fail classifications, and the domain-referenced reliability coefficients may be better indicators of reproducibility.

  19. Measurement uncertainty analysis techniques applied to PV performance measurements

    International Nuclear Information System (INIS)

    Wells, C.

    1992-10-01

    The purpose of this presentation is to provide a brief introduction to measurement uncertainty analysis, outline how it is done, and illustrate uncertainty analysis with examples drawn from the PV field, with particular emphasis toward its use in PV performance measurements. The uncertainty information we know and state concerning a PV performance measurement or a module test result determines, to a significant extent, the value and quality of that result. What is measurement uncertainty analysis? It is an outgrowth of what has commonly been called error analysis. But uncertainty analysis, a more recent development, gives greater insight into measurement processes and tests, experiments, or calibration results. Uncertainty analysis gives us an estimate of the I interval about a measured value or an experiment's final result within which we believe the true value of that quantity will lie. Why should we take the time to perform an uncertainty analysis? A rigorous measurement uncertainty analysis: Increases the credibility and value of research results; allows comparisons of results from different labs; helps improve experiment design and identifies where changes are needed to achieve stated objectives (through use of the pre-test analysis); plays a significant role in validating measurements and experimental results, and in demonstrating (through the post-test analysis) that valid data have been acquired; reduces the risk of making erroneous decisions; demonstrates quality assurance and quality control measures have been accomplished; define Valid Data as data having known and documented paths of: Origin, including theory; measurements; traceability to measurement standards; computations; uncertainty analysis of results

  20. Applying legal principles to stimulate open standards: the role of forums and consortia

    NARCIS (Netherlands)

    Hoenkamp, R.A.; Folmer, E.J.A.; Huitema, G.B

    2012-01-01

    In this paper it is argued that openness in standards raises its quality level. This study is done not only from a technical business administration point of view but also from a legal perspective. It is shown that applying legal principles, in particular the principles of Good Governance can

  1. 24 CFR 943.151 - What procurement standards apply to a joint venture itself?

    Science.gov (United States)

    2010-04-01

    ... a joint venture itself? 943.151 Section 943.151 Housing and Urban Development Regulations Relating... HOUSING, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT PUBLIC HOUSING AGENCY CONSORTIA AND JOINT VENTURES Subsidiaries, Affiliates, Joint Ventures in Public Housing § 943.151 What procurement standards apply to a...

  2. 24 CFR 943.150 - What procurement standards apply to a PHA's joint venture partner?

    Science.gov (United States)

    2010-04-01

    ... a PHA's joint venture partner? 943.150 Section 943.150 Housing and Urban Development Regulations... HOUSING, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT PUBLIC HOUSING AGENCY CONSORTIA AND JOINT VENTURES Subsidiaries, Affiliates, Joint Ventures in Public Housing § 943.150 What procurement standards apply to a PHA...

  3. 40 CFR 415.345 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true New source performance standards (NSPS). 415.345 Section 415.345 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY Chrome Pigments Production...

  4. 10 CFR 433.4 - Energy efficiency performance standard.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Energy efficiency performance standard. 433.4 Section 433.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR THE DESIGN AND... consumption level at or better than the maximum level of energy efficiency that is life-cycle cost-effective...

  5. 40 CFR 425.74 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.74 Section 425.74 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Shearling Subcategory § 425.74...

  6. 40 CFR 425.24 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.24 Section 425.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save, Chrome Tan, Retan-Wet...

  7. 40 CFR 425.34 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.34 Section 425.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Save or Pulp, Non-Chrome...

  8. 40 CFR 425.44 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.44 Section 425.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Retan-Wet Finish-Sides...

  9. 40 CFR 425.94 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.94 Section 425.94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Retan-Wet Finish-Splits...

  10. 40 CFR 425.84 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.84 Section 425.84 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Pigskin Subcategory § 425.84 New...

  11. 40 CFR 425.64 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.64 Section 425.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Through-the-Blue Subcategory...

  12. 40 CFR 425.54 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.54 Section 425.54 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY No Beamhouse Subcategory § 425...

  13. 40 CFR 425.14 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards (NSPS). 425.14 Section 425.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE CATEGORY Hair Pulp, Chrome Tan, Retan-Wet...

  14. 40 CFR 471.103 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... achieve the following new source performance standards (NSPS). The mass of pollutants in the metal powder process wastewater shall not exceed the following values: (a) Metal powder production atom-ization... GUIDELINES AND STANDARDS NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY Metals Powders...

  15. 40 CFR 471.73 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY Uranium Forming... achieve the following new source performance standards (NSPS). The mass of pollutants in the uranium... mg/off-kg (pounds per million off-pounds) of uranium extruded Cadmium 0.007 0.003 Chromium 0.013 0...

  16. Evaluation model applied to TRANSPETRO's Marine Terminals Standardization Program

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de; Mueller, Gabriela [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Garcia, Luciano Maldonado [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes an innovative evaluation model applied to TRANSPETRO's 'Marine Terminals Standardization Program' based on updating approaches of programs evaluation and organizational learning. Since the program was launched in 2004, the need for having an evaluation model able to evaluate its implementation progress, to measure the degree of standards compliance and its potential economic, social and environmental impacts has become evident. Within a vision of safe and environmentally responsible operations of marine terminals, this evaluation model was jointly designed by TRANSPETRO and PUC-Rio to promote continuous improvement and learning in operational practices and in the standardization process itself. TRANSPETRO believes that standardization supports its services and management innovation capability by creating objective and internationally recognized parameters, targets and metrology for its business activities. The conceptual model and application guidelines for this important tool are presented in this paper, as well as the next steps towards its implementation. (author)

  17. Measurement uncertainty analysis techniques applied to PV performance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Wells, C.

    1992-10-01

    The purpose of this presentation is to provide a brief introduction to measurement uncertainty analysis, outline how it is done, and illustrate uncertainty analysis with examples drawn from the PV field, with particular emphasis toward its use in PV performance measurements. The uncertainty information we know and state concerning a PV performance measurement or a module test result determines, to a significant extent, the value and quality of that result. What is measurement uncertainty analysis It is an outgrowth of what has commonly been called error analysis. But uncertainty analysis, a more recent development, gives greater insight into measurement processes and tests, experiments, or calibration results. Uncertainty analysis gives us an estimate of the I interval about a measured value or an experiment's final result within which we believe the true value of that quantity will lie. Why should we take the time to perform an uncertainty analysis A rigorous measurement uncertainty analysis: Increases the credibility and value of research results; allows comparisons of results from different labs; helps improve experiment design and identifies where changes are needed to achieve stated objectives (through use of the pre-test analysis); plays a significant role in validating measurements and experimental results, and in demonstrating (through the post-test analysis) that valid data have been acquired; reduces the risk of making erroneous decisions; demonstrates quality assurance and quality control measures have been accomplished; define Valid Data as data having known and documented paths of: Origin, including theory; measurements; traceability to measurement standards; computations; uncertainty analysis of results.

  18. Measurement uncertainty analysis techniques applied to PV performance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Wells, C

    1992-10-01

    The purpose of this presentation is to provide a brief introduction to measurement uncertainty analysis, outline how it is done, and illustrate uncertainty analysis with examples drawn from the PV field, with particular emphasis toward its use in PV performance measurements. The uncertainty information we know and state concerning a PV performance measurement or a module test result determines, to a significant extent, the value and quality of that result. What is measurement uncertainty analysis? It is an outgrowth of what has commonly been called error analysis. But uncertainty analysis, a more recent development, gives greater insight into measurement processes and tests, experiments, or calibration results. Uncertainty analysis gives us an estimate of the I interval about a measured value or an experiment`s final result within which we believe the true value of that quantity will lie. Why should we take the time to perform an uncertainty analysis? A rigorous measurement uncertainty analysis: Increases the credibility and value of research results; allows comparisons of results from different labs; helps improve experiment design and identifies where changes are needed to achieve stated objectives (through use of the pre-test analysis); plays a significant role in validating measurements and experimental results, and in demonstrating (through the post-test analysis) that valid data have been acquired; reduces the risk of making erroneous decisions; demonstrates quality assurance and quality control measures have been accomplished; define Valid Data as data having known and documented paths of: Origin, including theory; measurements; traceability to measurement standards; computations; uncertainty analysis of results.

  19. Radioactive material package test standards and performance requirements - public perception

    International Nuclear Information System (INIS)

    Pope, R.B.; Shappert, L.B.; Rawl, R.R.

    1992-01-01

    This paper addresses issues related to the public perception of the regulatory test standards and performance requirements for packaging and transporting radioactive material. Specifically, it addresses the adequacy of the package performance standards and testing for Type B packages, which are those packages designed for transporting the most hazardous quantities and forms of radioactive material. Type B packages are designed to withstand accident conditions in transport. To improve public perception, the public needs to better understand: (a) the regulatory standards and requirements themselves, (b) the extensive history underlying their development, and (c) the soundness of the technical foundation. The public needs to be fully informed on studies, tests, and analyses that have been carried out worldwide and form the basis of the regulatory standards and requirements. This paper provides specific information aimed at improving the public perception of packages test standards

  20. Preliminary results of testing bioassay analytical performance standards

    International Nuclear Information System (INIS)

    Fisher, D.R.; Robinson, A.V.; Hadley, R.T.

    1983-08-01

    The analytical performance of both in vivo and in vitro bioassay laboratories is being studied to determine the capability of these laboratories to meet the minimum criteria for accuracy and precision specified in the draft ANSI Standard N13.30, Performance Criteria for Radiobioassay. This paper presents preliminary results of the first round of testing

  1. 24 CFR 902.43 - Management operations performance standards.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Management operations performance... URBAN DEVELOPMENT PUBLIC HOUSING ASSESSMENT SYSTEM PHAS Indicator #3: Management Operations § 902.43 Management operations performance standards. (a) Management operations sub-indicators. The following sub...

  2. Performance Evaluation of Five Turbidity Sensors in Three Primary Standards

    Science.gov (United States)

    Snazelle, Teri T.

    2015-10-28

    Open-File Report 2015-1172 is temporarily unavailable.Five commercially available turbidity sensors were evaluated by the U.S. Geological Survey, Hydrologic Instrumentation Facility (HIF) for accuracy and precision in three types of turbidity standards; formazin, StablCal, and AMCO Clear (AMCO–AEPA). The U.S. Environmental Protection Agency (EPA) recognizes all three turbidity standards as primary standards, meaning they are acceptable for reporting purposes. The Forrest Technology Systems (FTS) DTS-12, the Hach SOLITAX sc, the Xylem EXO turbidity sensor, the Yellow Springs Instrument (YSI) 6136 turbidity sensor, and the Hydrolab Series 5 self-cleaning turbidity sensor were evaluated to determine if turbidity measurements in the three primary standards are comparable to each other, and to ascertain if the primary standards are truly interchangeable. A formazin 4000 nephelometric turbidity unit (NTU) stock was purchased and dilutions of 40, 100, 400, 800, and 1000 NTU were made fresh the day of testing. StablCal and AMCO Clear (for Hach 2100N) standards with corresponding concentrations were also purchased for the evaluation. Sensor performance was not evaluated in turbidity levels less than 40 NTU due to the unavailability of polymer-bead turbidity standards rated for general use. The percent error was calculated as the true (not absolute) difference between the measured turbidity and the standard value, divided by the standard value.The sensors that demonstrated the best overall performance in the evaluation were the Hach SOLITAX and the Hydrolab Series 5 turbidity sensor when the operating range (0.001–4000 NTU for the SOLITAX and 0.1–3000 NTU for the Hydrolab) was considered in addition to sensor accuracy and precision. The average percent error in the three standards was 3.80 percent for the SOLITAX and -4.46 percent for the Hydrolab. The DTS-12 also demonstrated good accuracy with an average percent error of 2.02 percent and a maximum relative standard

  3. On the measurement of the neutrino velocity applying the standard time of the Global Positioning System

    International Nuclear Information System (INIS)

    Skeivalas, J; Parseliunas, E

    2013-01-01

    The measurement of the neutrino velocity applying the standard time of the Global Positioning System (GPS) is presented in the paper. The practical data were taken from the OPERA experiment, in which neutrino emission from the CERN LHC accelerator to Gran Sasso detector was investigated. The distance between accelerator and detector is about 730 km. The time interval was measured by benchmark clocks, which were calibrated by the standard GPS time signals received from GPS satellites. The calculation of the accuracy of the GPS time signals with respect to changes of the signals' frequencies due to the Doppler effect is presented. It is shown that a maximum error of about 200 ns could occur when GPS time signals are applied for the calibration of the clocks for the neutrino velocity measurements. (paper)

  4. Fundamental Research Applied To Enable Hardware Performance in Microgravity

    Science.gov (United States)

    Sheredy, William A.

    2005-01-01

    NASA sponsors microgravity research to generate knowledge in physical sciences. In some cases, that knowledge must be applied to enable future research. This article describes one such example. The Dust and Aerosol measurement Feasibility Test (DAFT) is a risk-mitigation experiment developed at the NASA Glenn Research Center by NASA and ZIN Technologies, Inc., in support of the Smoke Aerosol Measurement Experiment (SAME). SAME is an investigation that is being designed for operation in the Microgravity Science Glovebox aboard the International Space Station (ISS). The purpose of DAFT is to evaluate the performance of P-Trak (TSI Incorporated, Shoreview, MN)--a commercially available condensation nuclei counter and a key SAME diagnostic- -in long-duration microgravity because of concerns about its ability to operate properly in that environment. If its microgravity performance is proven, this device will advance the state of the art in particle measurement capabilities for space vehicles and facilities, such as aboard the ISS. The P-Trak, a hand-held instrument, can count individual particles as small as 20 nm in diameter in an aerosol stream. Particles are drawn into the device by a built-in suction pump. Upon entering the instrument, these particles pass through a saturator tube where they mix with an alcohol vapor (see the following figure). This mixture then flows through a cooled condenser tube where some of the alcohol condenses onto the sample particles, and the droplets grow in a controlled fashion until they are large enough to be counted. These larger droplets pass through an internal nozzle and past a focused laser beam, producing flashes of light that are sensed by a photodetector and then counted to determine particle number concentration. The operation of the instrument depends on the proper internal flow and recycling of isopropyl alcohol in both the vapor and liquid phases.

  5. Setting Performance Standards for Technical and Nontechnical Competence in General Surgery.

    Science.gov (United States)

    Szasz, Peter; Bonrath, Esther M; Louridas, Marisa; Fecso, Andras B; Howe, Brett; Fehr, Adam; Ott, Michael; Mack, Lloyd A; Harris, Kenneth A; Grantcharov, Teodor P

    2017-07-01

    The objectives of this study were to (1) create a technical and nontechnical performance standard for the laparoscopic cholecystectomy, (2) assess the classification accuracy and (3) credibility of these standards, (4) determine a trainees' ability to meet both standards concurrently, and (5) delineate factors that predict standard acquisition. Scores on performance assessments are difficult to interpret in the absence of established standards. Trained raters observed General Surgery residents performing laparoscopic cholecystectomies using the Objective Structured Assessment of Technical Skill (OSATS) and the Objective Structured Assessment of Non-Technical Skills (OSANTS) instruments, while as also providing a global competent/noncompetent decision for each performance. The global decision was used to divide the trainees into 2 contrasting groups and the OSATS or OSANTS scores were graphed per group to determine the performance standard. Parametric statistics were used to determine classification accuracy and concurrent standard acquisition, receiver operator characteristic (ROC) curves were used to delineate predictive factors. Thirty-six trainees were observed 101 times. The technical standard was an OSATS of 21.04/35.00 and the nontechnical standard an OSANTS of 22.49/35.00. Applying these standards, competent/noncompetent trainees could be discriminated in 94% of technical and 95% of nontechnical performances (P < 0.001). A 21% discordance between technically and nontechnically competent trainees was identified (P < 0.001). ROC analysis demonstrated case experience and trainee level were both able to predict achieving the standards with an area under the curve (AUC) between 0.83 and 0.96 (P < 0.001). The present study presents defensible standards for technical and nontechnical performance. Such standards are imperative to implementing summative assessments into surgical training.

  6. Applying importance-performance analysis to patient safety culture.

    Science.gov (United States)

    Lee, Yii-Ching; Wu, Hsin-Hung; Hsieh, Wan-Lin; Weng, Shao-Jen; Hsieh, Liang-Po; Huang, Chih-Hsuan

    2015-01-01

    The Sexton et al.'s (2006) safety attitudes questionnaire (SAQ) has been widely used to assess staff's attitudes towards patient safety in healthcare organizations. However, to date there have been few studies that discuss the perceptions of patient safety both from hospital staff and upper management. The purpose of this paper is to improve and to develop better strategies regarding patient safety in healthcare organizations. The Chinese version of SAQ based on the Taiwan Joint Commission on Hospital Accreditation is used to evaluate the perceptions of hospital staff. The current study then lies in applying importance-performance analysis technique to identify the major strengths and weaknesses of the safety culture. The results show that teamwork climate, safety climate, job satisfaction, stress recognition and working conditions are major strengths and should be maintained in order to provide a better patient safety culture. On the contrary, perceptions of management and hospital handoffs and transitions are important weaknesses and should be improved immediately. Research limitations/implications - The research is restricted in generalizability. The assessment of hospital staff in patient safety culture is physicians and registered nurses. It would be interesting to further evaluate other staff's (e.g. technicians, pharmacists and others) opinions regarding patient safety culture in the hospital. Few studies have clearly evaluated the perceptions of healthcare organization management regarding patient safety culture. Healthcare managers enable to take more effective actions to improve the level of patient safety by investigating key characteristics (either strengths or weaknesses) that healthcare organizations should focus on.

  7. 36 CFR 1235.42 - What specifications and standards for transfer apply to audiovisual records, cartographic, and...

    Science.gov (United States)

    2010-07-01

    ... standards for transfer apply to audiovisual records, cartographic, and related records? 1235.42 Section 1235... Standards § 1235.42 What specifications and standards for transfer apply to audiovisual records... elements that are needed for future preservation, duplication, and reference for audiovisual records...

  8. Potential Performance Theory (PPT): A General Theory of Task Performance Applied to Morality

    Science.gov (United States)

    Trafimow, David; Rice, Stephen

    2008-01-01

    People can use a variety of different strategies to perform tasks and these strategies all have two characteristics in common. First, they can be evaluated in comparison with either an absolute or a relative standard. Second, they can be used at varying levels of consistency. In the present article, the authors develop a general theory of task…

  9. Factors Contributing to SMEs Failure in Meeting Supplier Performance Standards

    Directory of Open Access Journals (Sweden)

    van Scheers Louise

    2016-01-01

    Full Text Available This study sought to determine the factors that contribute to the failure of small and medium enterprises (SMEs in meeting supplier performance standards. Suppliers are faced with the challenge of SMEs failing to meet supplier performance standards because they rely on these providers of products and services, mainly SMEs, for their operations and to ultimately achieve their mandate. The researchers were able to establish the main factors contributing to SME failure in meeting supplier performance standards. These are as follows: unclear specifications and terms of references from suppliers; insufficient information provided to SME suppliers to ensure understanding of requirements; insufficient feedback and support; no support of SME suppliers based on their Black Economic Empowerment (BEE status; limited or no use of business support programs by SME suppliers; and external factors such as access to finance, changes in the economy, and location.

  10. Performance Measurement of Management System Standards Using the Balanced Scorecard

    Directory of Open Access Journals (Sweden)

    Jan Kopia

    2017-11-01

    Full Text Available Management system standards (MSS, such as ISO standards, TQM, etc. are widely-used standards adopted by millions of organizations worldwide. It is still an unclear question whether these standards are beneficial for an organization, besides the fact that they might be required or expected by law or customers. The question, whether MSS increase the efficiency, the output, or the performance of an organization is still discussed in scientific research. One reason might be that performance measurement itself is not fully understood or in constant development ranging from pure financial evaluations over intellectual capital rating to calculating of levels of environmental, social or economic expectations known as the Trible Bottom Line. The Balanced Scorecard is one possible solution for performance measurement on a strategic and operational level and therefore useful for the measurement of the influence of MSS within organizations. This study summarized current research in the field of performance measurement in the context of MSS and IMS and the use of BSC and quantitatively and qualitatively tests the usefulness of BSC in measuring the effect of MSSs using the Execution Premium. It was found that BSC is often used, that an average number of companies integrate their measurement initiatives of their MSSs into the BSC-process, and that a high integration of MSS into the BSC improves the organizational performance. This research is useful for researchers and practitioners in order to understand the benefits of the usage of the BSC in the context of MSS or Integrated Management Systems.

  11. Performance assurance of the re-applying project documentation

    Science.gov (United States)

    Kozlova, Olga

    2017-10-01

    Usage of the re-applying project documentation is cost effective measure. Saving of budgetary funds for purchases for development of new project documentation occurs by means of it. It also becomes possible to consider better decisions and prevent the repetition of mistakes. Nowadays, state authorities in construction management are forming separate institute for re-applying project documentation. The article shows the main tasks of such events and the issues to be solved for achievement of a high positive result.

  12. Performance of an extrapolation chamber in computed tomography standard beams

    International Nuclear Information System (INIS)

    Castro, Maysa C.; Silva, Natália F.; Caldas, Linda V.E.

    2017-01-01

    Among the medical uses of ionizing radiations, the computed tomography (CT) diagnostic exams are responsible for the highest dose values to the patients. The dosimetry procedure in CT scanner beams makes use of pencil ionization chambers with sensitive volume lengths of 10 cm. The aim of its calibration is to compare the values that are obtained with the instrument to be calibrated and a standard reference system. However, there is no primary standard system for this kind of radiation beam. Therefore, an extrapolation ionization chamber built at the Calibration Laboratory (LCI), was used to establish a CT primary standard. The objective of this work was to perform some characterization tests (short- and medium-term stabilities, saturation curve, polarity effect and ion collection efficiency) in the standard X-rays beams established for computed tomography at the LCI. (author)

  13. Performance of an extrapolation chamber in computed tomography standard beams

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Maysa C.; Silva, Natália F.; Caldas, Linda V.E., E-mail: mcastro@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Among the medical uses of ionizing radiations, the computed tomography (CT) diagnostic exams are responsible for the highest dose values to the patients. The dosimetry procedure in CT scanner beams makes use of pencil ionization chambers with sensitive volume lengths of 10 cm. The aim of its calibration is to compare the values that are obtained with the instrument to be calibrated and a standard reference system. However, there is no primary standard system for this kind of radiation beam. Therefore, an extrapolation ionization chamber built at the Calibration Laboratory (LCI), was used to establish a CT primary standard. The objective of this work was to perform some characterization tests (short- and medium-term stabilities, saturation curve, polarity effect and ion collection efficiency) in the standard X-rays beams established for computed tomography at the LCI. (author)

  14. A tool for standardized collector performance calculations including PVT

    DEFF Research Database (Denmark)

    Perers, Bengt; Kovacs, Peter; Olsson, Marcus

    2012-01-01

    A tool for standardized calculation of solar collector performance has been developed in cooperation between SP Technical Research Institute of Sweden, DTU Denmark and SERC Dalarna University. The tool is designed to calculate the annual performance of solar collectors at representative locations...... can be tested and modeled as a thermal collector, when the PV electric part is active with an MPP tracker in operation. The thermal collector parameters from this operation mode are used for the PVT calculations....

  15. Testing of camera performance standards at steady and local overloading

    International Nuclear Information System (INIS)

    Keszthelyine Landori, S.; Adorjanne Farkas, M.; Csirik, J.

    1983-01-01

    Camera performance standards are usually given for low count rates and uniform irradiation. A conventional analog gamma camera system (Gamma MB 9100 manufactured under the know-how of Picker DC 4/12 in Hungary) was studied on the basis of the Picker test procedure and the NEMA standard system. Uniformity, linearity, spatial and energy resolution were measured at high count rates and uniform irradiation (steady overloading). Linearity was studied at local overloading. Linearity, spatial and energy resolution were measured by a 1024-channel analyzer-computer system of KFKI, Hungary. The data were evaluated on the basis of NEMA standards, while uniformity was measured by the Gamma data processing system and evaluated by special SEGAMS programs. Performance variations were studied between 7500 cps and 75.000 cps pulse rates. Spatial and energy resolution were influenced strongly, uniformity slightly by pulse rates, while linearity did not change at all. Linearity was not influenced even by local overloading. (author)

  16. 6 CFR 27.230 - Risk-based performance standards.

    Science.gov (United States)

    2010-01-01

    ... 6 Domestic Security 1 2010-01-01 2010-01-01 false Risk-based performance standards. 27.230 Section 27.230 Domestic Security DEPARTMENT OF HOMELAND SECURITY, OFFICE OF THE SECRETARY CHEMICAL FACILITY... the facility and that discourages abuse through established disciplinary measures; (4) Deter, Detect...

  17. 20 CFR 404.1641 - Standards of performance.

    Science.gov (United States)

    2010-04-01

    ... appropriate Regional Commissioner after negotiation with each State agency. The intermediate goals are... considering the State agency to be substantially failing to comply with the performance standards. However... 404.1641 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE, SURVIVORS AND DISABILITY...

  18. 20 CFR 416.1041 - Standards of performance.

    Science.gov (United States)

    2010-04-01

    ... appropriate Regional Commissioner after negotiation with each State agency. The intermediate goals are... considering the State agency to be substantially failing to comply with the performance standards. However... 416.1041 Employees' Benefits SOCIAL SECURITY ADMINISTRATION SUPPLEMENTAL SECURITY INCOME FOR THE AGED...

  19. 40 CFR 430.25 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... Soda Subcategory § 430.25 New source performance standards (NSPS). New sources subject to this subpart... fine papers are produced and soda facilities where pulp and paper are produced] Pollutant or pollutant... that does not use an exclusively TCF bleaching process, as disclosed by the discharger in its NPDES...

  20. Vocational and Technical Education Performance Standards and Competencies.

    Science.gov (United States)

    Connecticut State Board of Education, Hartford.

    These Connecticut vocational and technical performance standards and competencies are a guide for overall quality attainment in these seven vocational and technical program areas: agricultural science technology education; business and finance technology education; cooperative work education; family and consumer sciences education; marketing…

  1. 30 CFR 827.12 - Coal preparation plants: Performance standards.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Coal preparation plants: Performance standards...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.12 Coal preparation plants..., modification, reclamation, and removal activities at coal preparation plants shall comply with the following...

  2. Using SWE Standards for Ubiquitous Environmental Sensing: A Performance Analysis

    Directory of Open Access Journals (Sweden)

    Joaquín Huerta

    2012-08-01

    Full Text Available Although smartphone applications represent the most typical data consumer tool from the citizen perspective in environmental applications, they can also be used for in-situ data collection and production in varied scenarios, such as geological sciences and biodiversity. The use of standard protocols, such as SWE, to exchange information between smartphones and sensor infrastructures brings benefits such as interoperability and scalability, but their reliance on XML is a potential problem when large volumes of data are transferred, due to limited bandwidth and processing capabilities on mobile phones. In this article we present a performance analysis about the use of SWE standards in smartphone applications to consume and produce environmental sensor data, analysing to what extent the performance problems related to XML can be alleviated by using alternative uncompressed and compressed formats.

  3. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    We identify one potential source of bias that influences children’s performance on standardized tests and that is predictable based on psychological theory: the time at which students take the test. Using test data for all children attending Danish public schools between school years 2009....../10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus......, as the day wears on, students become increasingly fatigued and consequently more likely to underperform on a standardized test....

  4. Performance evaluation of emerging JPEGXR compression standard for medical images

    International Nuclear Information System (INIS)

    Basit, M.A.

    2012-01-01

    Medical images require loss less compression as a small error due to lossy compression may be considered as a diagnostic error. JPEG XR is the latest image compression standard designed for variety of applications and has a support for lossy and loss less modes. This paper provides in-depth performance evaluation of latest JPEGXR with existing image coding standards for medical images using loss less compression. Various medical images are used for evaluation and ten images of each organ are tested. Performance of JPEGXR is compared with JPEG2000 and JPEGLS using mean square error, peak signal to noise ratio, mean absolute error and structural similarity index. JPEGXR shows improvement of 20.73 dB and 5.98 dB over JPEGLS and JPEG2000 respectively for various test images used in experimentation. (author)

  5. Standard Guide for Specifying Thermal Performance of Geothermal Power Systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide covers power plant performance terms and criteria for use in evaluation and comparison of geothermal energy conversion and power generation systems. The special nature of these geothermal systems makes performance criteria commonly used to evaluate conventional fossil fuel-fired systems of limited value. This guide identifies the limitations of the less useful criteria and defines an equitable basis for measuring the quality of differing thermal cycles and plant equipment for geothermal resources. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Standards of performance and aesthetics in counselling and beyond

    DEFF Research Database (Denmark)

    Nissen, Morten

    2016-01-01

    The article discusses performance standards in relation to Danish experiments with expanding drug counselling into ‘aesthetic documentation’ which is a hybrid of art with narrative practice. This relation is problematic, since the instrumental use defies the point in art, and since ‘aesthetic...... subjectivity. Then five claims are made about ‘aesthetic documentation’ as an alternative: The art works can be seen as prototypes rather than rigid standardizations; they represent collaboration rather than individualized performance; they work as staging or display in close connection with the substantial...... meaning of activities and their products; they objectify and thus achieve social recognition of clients and professionals; as art, they open to flexible, diverse and transforming attributions of meaning and value; and they address social problems rather than individualized malfunctions. In conclusion...

  7. Force coordination in static manipulation tasks performed using standard and non-standard grasping techniques.

    Science.gov (United States)

    de Freitas, Paulo B; Jaric, Slobodan

    2009-04-01

    We evaluated coordination of the hand grip force (GF; normal component of the force acting at the hand-object contact area) and load force (LF; the tangential component) in a variety of grasping techniques and two LF directions. Thirteen participants exerted a continuous sinusoidal LF pattern against externally fixed handles applying both standard (i.e., using either the tips of the digits or the palms; the precision and palm grasps, respectively) and non-standard grasping techniques (using wrists and the dorsal finger areas; the wrist and fist grasp). We hypothesized (1) that the non-standard grasping techniques would provide deteriorated indices of force coordination when compared with the standard ones, and (2) that the nervous system would be able to adjust GF to the differences in friction coefficients of various skin areas used for grasping. However, most of the indices of force coordination remained similar across the tested grasping techniques, while the GF adjustments for the differences in friction coefficients (highest in the palm and the lowest in the fist and wrist grasp) provided inconclusive results. As hypothesized, GF relative to the skin friction was lowest in the precision grasp, but highest in the palm grasp. Therefore, we conclude that (1) the elaborate coordination of GF and LF consistently seen across the standard grasping techniques could be generalized to the non-standard ones, while (2) the ability to adjust GF using the same grasping technique to the differences in friction of various objects cannot be fully generalized to the GF adjustment when different grasps (i.e., hand segments) are used to manipulate the same object. Due to the importance of the studied phenomena for understanding both the functional and neural control aspects of manipulation, future studies should extend the current research to the transient and dynamic tasks, as well as to the general role of friction in our mechanical interactions with the environment.

  8. 40 CFR 80.216 - What standards apply to gasoline produced or imported for use in the GPA?

    Science.gov (United States)

    2010-07-01

    ... Geographic Phase-in Program § 80.216 What standards apply to gasoline produced or imported for use in the GPA? (a) The refinery or importer annual average sulfur standard for gasoline produced or imported for use...), shall be 150.00 ppm. (b) The per-gallon cap standard for gasoline produced or imported for use in the...

  9. UK key performance indicators and quality assurance standards for colonoscopy.

    Science.gov (United States)

    Rees, Colin J; Thomas Gibson, Siwan; Rutter, Matt D; Baragwanath, Phil; Pullan, Rupert; Feeney, Mark; Haslam, Neil

    2016-12-01

    Colonoscopy should be delivered by endoscopists performing high quality procedures. The British Society of Gastroenterology, the UK Joint Advisory Group on GI Endoscopy, and the Association of Coloproctology of Great Britain and Ireland have developed quality assurance measures and key performance indicators for the delivery of colonoscopy within the UK. This document sets minimal standards for delivery of procedures along with aspirational targets that all endoscopists should aim for. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Self-assessment: Strategy for higher standards, consistency, and performance

    International Nuclear Information System (INIS)

    Ide, W.E.

    1996-01-01

    In late 1994, Palo Verde operations underwent a transformation from a unitized structure to a single functional unit. It was necessary to build consistency in watchstanding practices and create a shared mission. Because there was a lack of focus on actual plant operations and because personnel were deeply involved with administrative tasks, command and control of evolutions were weak. Improvement was needed. Consistent performance standards have been set for all three operating units. These expectation focus on nuclear, radiological, and industrial safety. Straightforward descriptions of watchstanding and monitoring practices have been provided to all department personnel. The desired professional and leadership qualities for employee conduct have been defined and communicated thoroughly. A healthy and competitive atmosphere developed with the successful implementation of these standards. Overall performance improved. The auxiliary operators demonstrated increased pride and ownership in the performance of their work activities. In addition, their morale improved. Crew teamwork improved as well as the quality of shift briefs. There was a decrease in the noise level and the administrative functions in the control room. The use of self-assessment helped to anchor and define higher and more consistent standards. The proof of Palo Verde's success was evident when an Institute of Nuclear Power Operations finding was turned into a strength within 1 yr

  11. Performance analysis of numeric solutions applied to biokinetics of radionuclides

    International Nuclear Information System (INIS)

    Mingatos, Danielle dos Santos; Bevilacqua, Joyce da Silva

    2013-01-01

    Biokinetics models for radionuclides applied to dosimetry problems are constantly reviewed by ICRP. The radionuclide trajectory could be represented by compartmental models, assuming constant transfer rates between compartments. A better understanding of physiological or biochemical phenomena, improve the comprehension of radionuclide behavior in the human body and, in general, more complex compartmental models are proposed, increasing the difficulty of obtaining the analytical solution for the system of first order differential equations. Even with constant transfer rates numerical solutions must be carefully implemented because of almost singular characteristic of the matrix of coefficients. In this work we compare numerical methods with different strategies for ICRP-78 models for Thorium-228 and Uranium-234. The impact of uncertainty in the parameters of the equations is also estimated for local and global truncation errors. (author)

  12. Applying emerging digital video interface standards to airborne avionics sensor and digital map integrations: benefits outweigh the initial costs

    Science.gov (United States)

    Kuehl, C. Stephen

    1996-06-01

    Video signal system performance can be compromised in a military aircraft cockpit management system (CMS) with the tailoring of vintage Electronics Industries Association (EIA) RS170 and RS343A video interface standards. Video analog interfaces degrade when induced system noise is present. Further signal degradation has been traditionally associated with signal data conversions between avionics sensor outputs and the cockpit display system. If the CMS engineering process is not carefully applied during the avionics video and computing architecture development, extensive and costly redesign will occur when visual sensor technology upgrades are incorporated. Close monitoring and technical involvement in video standards groups provides the knowledge-base necessary for avionic systems engineering organizations to architect adaptable and extendible cockpit management systems. With the Federal Communications Commission (FCC) in the process of adopting the Digital HDTV Grand Alliance System standard proposed by the Advanced Television Systems Committee (ATSC), the entertainment and telecommunications industries are adopting and supporting the emergence of new serial/parallel digital video interfaces and data compression standards that will drastically alter present NTSC-M video processing architectures. The re-engineering of the U.S. Broadcasting system must initially preserve the electronic equipment wiring networks within broadcast facilities to make the transition to HDTV affordable. International committee activities in technical forums like ITU-R (former CCIR), ANSI/SMPTE, IEEE, and ISO/IEC are establishing global consensus on video signal parameterizations that support a smooth transition from existing analog based broadcasting facilities to fully digital computerized systems. An opportunity exists for implementing these new video interface standards over existing video coax/triax cabling in military aircraft cockpit management systems. Reductions in signal

  13. Performance Enhancement of the Patch Antennas Applying Micromachining Technology

    Directory of Open Access Journals (Sweden)

    Mohamed N. Azermanesh

    2007-09-01

    Full Text Available This paper reports on the application of micromachining technology for performance enhancement of two types of compact antennas which are becoming a common practice in microsystems. Shorted patch antennas (SPA and folded shorted patch antennas operating in the 5-6 GHz ISM band, with intended application in short-range wireless communications, are considered. The electrical length of antennas are modified by etching the substrate of the antennas, thus providing a new degree of freedom to control the antenna operating properties, which is the main novelty of our work. The gain and bandwidth of the antennas are increased by increasing the etching depth. However, etching the substrate affects the operating frequency as well. To keep the operating frequency at a pre-specified value, the dimension of the antennas must be increased by deepening the etching depth. Therefore, a trade off between the performance enhancement of the antennas and the dimensional enlargement is required.

  14. PERFORMANCE INDICATORS APPLIED TO BRAZILIAN PRIVATE EDUCATIONAL INSTITUTIONS

    Directory of Open Access Journals (Sweden)

    Átila de Melo Lira

    2015-06-01

    Full Text Available Initially focused on for-profit companies the Balance Scorecard (BSC has been adopted by many organizations with different objectives, such as higher education institutions (HEIs. However, it is not clear if the adoption of the BSC model is appropriate, or yet is hard to perceive how HEIs have modified and implemented this tool for evaluating educational institutions, public or privates, in Brazil. This study aims to fill the gap existent in the context of using the BSC in organizations. We intend to demonstrate how these organizations use performance indicators to measure their primary activities. A quantitative and exploratory study was developed from the analysis of performance indicators found in the web sites to Brazilian universities. A total of 91 Brazilian private universities evaluation process were reviewed. Even with a considerable amount of private HEIs there are few that have performance indicators guided by numerical and statistical data covering its main activities which is a concern for their managers in terms of managerial control.

  15. 40 CFR 427.35 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Paper (Starch Binder) Subcategory § 427.35 Standards of performance for new sources. The following standards of...

  16. 40 CFR 427.45 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Paper (Elastomeric Binder) Subcategory § 427.45 Standards of performance for new sources. The following standards of...

  17. Levitation performance of YBCO bulk in different applied magnetic fields

    International Nuclear Information System (INIS)

    Liu, W.; Wang, S.Y.; Jing, H.; Zheng, J.; Jiang, M.; Wang, J.S.

    2008-01-01

    The maglev performance of bulk high-T c superconductor (HTS) is investigated above three different types of permanent magnet guideways (PMGs). The main difference among these PMGs is the method used to concentrate the magnetic flux. The experimental results indicate that the levitation force depends only in part on the peak value of the magnetic field. The variation of the vertical component of the magnetic field (B z ), and the structure of the magnetic field are also responsible for the levitation force. These results imply that the permanent magnet with high coercive force is better at concentrating flux th an iron. The conclusions contribute in a very helpful way to the design and optimization of PMGs for HTS maglev systems

  18. Levitation performance of YBCO bulk in different applied magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Liu, W. [Applied Superconductivity Laboratory, Southwest Jiaotong University, Chengdu 610031 (China)], E-mail: asclab@asclab.cn; Wang, S.Y.; Jing, H.; Zheng, J.; Jiang, M.; Wang, J.S. [Applied Superconductivity Laboratory, Southwest Jiaotong University, Chengdu 610031 (China)

    2008-07-01

    The maglev performance of bulk high-T{sub c} superconductor (HTS) is investigated above three different types of permanent magnet guideways (PMGs). The main difference among these PMGs is the method used to concentrate the magnetic flux. The experimental results indicate that the levitation force depends only in part on the peak value of the magnetic field. The variation of the vertical component of the magnetic field (B{sub z}), and the structure of the magnetic field are also responsible for the levitation force. These results imply that the permanent magnet with high coercive force is better at concentrating flux th an iron. The conclusions contribute in a very helpful way to the design and optimization of PMGs for HTS maglev systems.

  19. Applying importance-performance analysis to evaluate banking service quality

    Directory of Open Access Journals (Sweden)

    André Luís Policani Freitas

    2012-11-01

    Full Text Available In an increasingly competitive market, the identification of the most important aspects and the measurement of service quality as perceived by the customers are important actions taken by organizations which seek the competitive advantage. In particular, this scenario is typical of Brazilian banking sector. In this context, this article presents an exploratory case study in which the Importance-Performance Analysis (IPA was used to identify the strong and the weak points related to services provided by a bank. In order to check the reliability of the questionnaire, Cronbach's alpha and correlation analyses were used. The results are presented and some actions have been defined in order to improve the quality of services.

  20. Academy of Nutrition and Dietetics: standards of practice and standards of professional performance for registered dietitian nutritionists (competent, proficient, and expert) in adult weight management.

    Science.gov (United States)

    Jortberg, Bonnie; Myers, Eileen; Gigliotti, Linda; Ivens, Barbara J; Lebre, Monica; Burke March, Susan; Nogueira, Isadora; Nwankwo, Robin; Parkinson, Meredith R; Paulsen, Barbara; Turner, Tonya

    2015-04-01

    Weight management encompasses the inter-relationship of nutrition, physical activity, and health behavior change. Nutrition is key for the prevention and treatment of obesity and chronic disease and maintenance of overall health. Thus, the Weight Management Dietetic Practice Group, with guidance from the Academy of Nutrition and Dietetics Quality Management Committee, has developed Standards of Practice and Standards of Professional Performance for Registered Dietitian Nutritionists (RDNs) in Adult Weight Management as a resource for RDNs working in weight management. This document allows RDNs to assess their current skill levels and to identify areas for further professional development in this expanding practice area. This document describes the current standards for weight management practice for RDNs. The Standards of Practice represent the four steps in the Nutrition Care Process as applied to the care of patients/clients. The Standards of Professional Performance consist of six domains of professionalism: Quality in Practice, Competence and Accountability, Provision of Services, Application of Research, Communication and Application of Knowledge, and Utilization and Management of Resources. Within each standard, specific indicators provide measurable action statements that illustrate how the standard can be applied to practice. The indicators describe three skill levels (competent, proficient, and expert) for RDNs working in weight management. The Standards of Practice and Standards of Professional Performance are complementary resources for the Registered Dietitian Nutritionist in weight management. Copyright © 2015 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  1. Considerations in the development of subsurface containment barrier performance standards

    International Nuclear Information System (INIS)

    Dunstan, S.; Zdinak, A.P.; Lodman, D.

    1997-01-01

    The U.S. Department of Energy (DOE) is supporting subsurface barriers as an alternative remedial option for management of contamination problems at their facilities. Past cleanup initiatives have sometimes proven ineffective or extremely expensive. Economic considerations coupled with changing public and regulatory philosophies regarding remediation techniques makes subsurface barriers a promising technology for future cleanup efforts. As part of the initiative to develop subsurface containment barriers as an alternative remedial option, DOE funded MSE Technology Applications, Inc. (MSE) to conduct a comprehensive review to identify performance considerations for the acceptability of subsurface barrier technologies as a containment method. Findings from this evaluation were intended to provide a basis for selection and application of containment technologies to address waste problems at DOE sites. Based on this study, the development of performance standards should consider: (1) sustainable low hydraulic conductivity; (2) capability to meet applicable regulations; (3) compatibility with subsurface environmental conditions; (4) durability and long-term stability; (5) repairability; and (6) verification and monitoring. This paper describes the approach for determining considerations for performance standards

  2. Academy of nutrition and dietetics: revised 2014 standards of practice and standards of professional performance for registered dietitian nutritionists (competent, proficient, and expert) in sports nutrition and dietetics.

    Science.gov (United States)

    Steinmuller, Patricia L; Kruskall, Laura J; Karpinski, Christine A; Manore, Melinda M; Macedonio, Michele A; Meyer, Nanna L

    2014-04-01

    Sports nutrition and dietetics addresses relationships of nutrition with physical activity, including weight management, exercise, and physical performance. Nutrition plays a key role in the prevention and treatment of obesity and chronic disease and for maintenance of health, and the ability to engage in physical activity, sports, and other aspects of physical performance. Thus, the Sports, Cardiovascular, and Wellness Nutrition Dietetic Practice Group, with guidance from the Academy of Nutrition and Dietetics Quality Management Committee, has developed the Revised 2014 Standards of Practice and Standards of Professional Performance as a resource for Registered Dietitian Nutritionists working in sports nutrition and dietetics to assess their current skill levels and to identify areas for further professional development in this emerging practice area. The revised document reflects advances in sports nutrition and dietetics practice since the original standards were published in 2009 and replaces those standards. The Standards of Practice represents the four steps in the Nutrition Care Process as applied to the care of patients/clients. The Standards of Professional Performance covers six standards of professional performance: quality in practice, competence and accountability, provision of services, application of research, communication and application of knowledge, and utilization and management of resources. Within each standard, specific indicators provide measurable action statements that illustrate how the standards can be applied to practice. The indicators describe three skill levels (competent, proficient, and expert) for Registered Dietitian Nutritionists working in sports nutrition and dietetics. The Standards of Practice and Standards of Professional Performance are complementary resources for Registered Dietitian Nutritionists in sports nutrition and dietetics practice. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc

  3. Performance evaluation of the EM algorithm applied to radiographic images

    International Nuclear Information System (INIS)

    Brailean, J.C.; Giger, M.L.; Chen, C.T.; Sullivan, B.J.

    1990-01-01

    In this paper the authors evaluate the expectation maximization (EM) algorithm, both qualitatively and quantitatively, as a technique for enhancing radiographic images. Previous studies have qualitatively shown the usefulness of the EM algorithm but have failed to quantify and compare its performance with those of other image processing techniques. Recent studies by Loo et al, Ishida et al, and Giger et al, have explained improvements in image quality quantitatively in terms of a signal-to-noise ratio (SNR) derived from signal detection theory. In this study, we take a similar approach in quantifying the effect of the EM algorithm on detection of simulated low-contrast square objects superimposed on radiographic mottle. The SNRs of the original and processed images are calculated taking into account both the human visual system response and the screen-film transfer function as well as a noise component internal to the eye-brain system. The EM algorithm was also implemented on digital screen-film images of test patterns and clinical mammograms

  4. Academic performance in terms of the applied assessment system

    Directory of Open Access Journals (Sweden)

    Arribas, José María

    2012-05-01

    Full Text Available This paper examines the academic performance depending on the evaluation and rating system used in the university. The sample under study consists of 30 subjects -taught by 35 professors to 2192 students from 7 different degrees at 14 universities of all Spain-. The results confirm that continuous assessment is the one that best results not only in terms of rate of return and success rate but also in terms of grades. En este trabajo se estudia el rendimiento académico en función del sistema de evaluación y calificación empleado en el ámbito universitario. La muestra objeto de estudio está formada por 30 asignaturas -impartidas por 35 profesores a 2192 alumnos de 7 titulaciones diferentes en 14 universidades de toda España-. Los resultados obtenidos confirman que la evaluación continua es la que propicia los mejores resultados no solo en cuanto a la Tasa de Rendimiento y a la Tasa de Éxito, sino también en cuanto a las calificaciones obtenidas.

  5. Alternate performance standard project: Interpreting the post-construction test

    International Nuclear Information System (INIS)

    Williamson, A.D.; McDonough, S.E.

    1993-01-01

    The paper describes the results of a project commissioned by the State of Florida, in cooperation with the US Environmental Protection Agency, as one portion of the Florida Radon Research Program (FRRP). The purpose of the FRRP is to provide technical support for a statewide Building Standard for Radon-Resistant Construction currently in the rulemaking process. In this case the information provides technical background for a post-construction radon test specified as a performance element of the code which accompanies the prescriptive alternative that does not incorporate active radon reduction systems

  6. FACTORS AFFECTING THE COMPLIANCE OF MYANMAR NURSES IN PERFORMING STANDARD PRECAUTION

    Directory of Open Access Journals (Sweden)

    Sa Sa Aung

    2017-06-01

    Full Text Available Introduction: Exposure to pathogens is a serious issue for nurses. The literature explains that standard precaution have not consistently done in nursing. The purpose of this study was to analyze the factors affecting the compliance of nurses in Myanmar in performing standard precautions. Methods: This study used a cross-sectional design. Samples included 34 nurses in Waibagi Specialist Hospital (SHW, Myanmar. The independent variables were the characteristics of nurses, knowledge of standard precaution, and exposure to blood / body fluids and needle puncture wounds. The dependent variable was the performance of standard prevention. Data analyzed using descriptive analysis and logistic regression. Results: The result showed that almost respondents (91.18% had a good knowledge about prevention standards and 73.5% of respondents had good adherence in performing standard precaution. However, in practice nurses have not been consistent in closing the needles that have been used correctly. The results showed that nurse characteristics did not significantly affect adherence to standard precaution with statistical test results as follows: age (p = 0.97, gender (p = 1.00, religion (p = 0.72, education (p = 0.85, work experience at SHW (p = 0, 84, education training program (p = 0.71, knowledge (p = 0.76, and needle stick injury (p = 0,17. But, there was a significant influence between adherence to standard precaution on the incidence of injury due to puncture needle with p value = 0.01. Discussion: The barriers to applying standard precautions by Myanmar nurses can be reduced by providing basic training, supervision and improvement of operational standard procedures.

  7. Relating Standardized Visual Perception Measures to Simulator Visual System Performance

    Science.gov (United States)

    Kaiser, Mary K.; Sweet, Barbara T.

    2013-01-01

    Human vision is quantified through the use of standardized clinical vision measurements. These measurements typically include visual acuity (near and far), contrast sensitivity, color vision, stereopsis (a.k.a. stereo acuity), and visual field periphery. Simulator visual system performance is specified in terms such as brightness, contrast, color depth, color gamut, gamma, resolution, and field-of-view. How do these simulator performance characteristics relate to the perceptual experience of the pilot in the simulator? In this paper, visual acuity and contrast sensitivity will be related to simulator visual system resolution, contrast, and dynamic range; similarly, color vision will be related to color depth/color gamut. Finally, we will consider how some characteristics of human vision not typically included in current clinical assessments could be used to better inform simulator requirements (e.g., relating dynamic characteristics of human vision to update rate and other temporal display characteristics).

  8. Improving health, safety and energy efficiency in New Zealand through measuring and applying basic housing standards.

    Science.gov (United States)

    Gillespie-Bennett, Julie; Keall, Michael; Howden-Chapman, Philippa; Baker, Michael G

    2013-08-02

    Substandard housing is a problem in New Zealand. Historically there has been little recognition of the important aspects of housing quality that affect people's health and safety. In this viewpoint article we outline the importance of assessing these factors as an essential step to improving the health and safety of New Zealanders and household energy efficiency. A practical risk assessment tool adapted to New Zealand conditions, the Healthy Housing Index (HHI), measures the physical characteristics of houses that affect the health and safety of the occupants. This instrument is also the only tool that has been validated against health and safety outcomes and reported in the international peer-reviewed literature. The HHI provides a framework on which a housing warrant of fitness (WOF) can be based. The HHI inspection takes about one hour to conduct and is performed by a trained building inspector. To maximise the effectiveness of this housing quality assessment we envisage the output having two parts. The first would be a pass/fail WOF assessment showing whether or not the house meets basic health, safety and energy efficiency standards. The second component would rate each main assessment area (health, safety and energy efficiency), potentially on a five-point scale. This WOF system would establish a good minimum standard for rental accommodation as well encouraging improved housing performance over time. In this article we argue that the HHI is an important, validated, housing assessment tool that will improve housing quality, leading to better health of the occupants, reduced home injuries, and greater energy efficiency. If required, this tool could be extended to also cover resilience to natural hazards, broader aspects of sustainability, and the suitability of the dwelling for occupants with particular needs.

  9. 13 CFR 121.409 - What size standard applies in an unrestricted procurement for Certificate of Competency purposes?

    Science.gov (United States)

    2010-01-01

    ... Standards Size Eligibility Requirements for Government Procurement § 121.409 What size standard applies in an unrestricted procurement for Certificate of Competency purposes? For the purpose of receiving a... unrestricted procurement for Certificate of Competency purposes? 121.409 Section 121.409 Business Credit and...

  10. The influence of anthropometrics on physical employment standard performance.

    Science.gov (United States)

    Reilly, T; Spivock, M; Prayal-Brown, A; Stockbrugger, B; Blacklock, R

    2016-10-01

    The Canadian Armed Forces (CAF) recently implemented the Fitness for Operational Requirements of CAF Employment (FORCE), a new physical employment standard (PES). Data collection throughout development included anthropometric profiles of the CAF. To determine if anthropometric measurements and demographic information would predict the performance outcomes of the FORCE and/or Common Military Task Fitness Evaluation (CMTFE). We conducted a secondary analysis of data from FORCE research. We obtained bioelectrical impedance and segmental analysis. Statistical analysis included correlation and linear regression analyses. Among the 668 study subjects, as predicted, any task requiring lifting, pulling or moving of an object was significantly and positively correlated (r > 0.67) to lean body mass (LBM) measurements. LBM correlated with stretcher carry (r = 0.78) and with lifting actions such as sand bag drag (r = 0.77), vehicle extrication (r = 0.71), sand bag fortification (r = 0.68) and sand bag lift time (r = -0.67). The difference between the correlation of dead mass (DM) with task performance compared with LBM was not statistically significant. DM and LBM can be used in a PES to predict success on military tasks such as casualty evacuation and manual material handling. However, there is no minimum LBM required to perform these tasks successfully. These data direct future research on how we should diversify research participants by anthropometrics, in addition to the traditional demographic variables of gender and age, to highlight potential important adverse impact with PES design. In addition, the results can be used to develop better training regimens to facilitate passing a PES. © All rights reserved. ‘The Influence of Anthropometrics on Physical Employment Standard Performance’ has been reproduced with the permission of DND, 2016.

  11. 40 CFR 80.350 - What alternative sulfur standards and requirements apply to importers who transport gasoline by...

    Science.gov (United States)

    2010-07-01

    ... requirements apply to importers who transport gasoline by truck? 80.350 Section 80.350 Protection of... ADDITIVES Gasoline Sulfur Sampling, Testing and Retention Requirements for Refiners and Importers § 80.350 What alternative sulfur standards and requirements apply to importers who transport gasoline by truck...

  12. A survey of NASA and military standards on fault tolerance and reliability applied to robotics

    Science.gov (United States)

    Cavallaro, Joseph R.; Walker, Ian D.

    1994-01-01

    There is currently increasing interest and activity in the area of reliability and fault tolerance for robotics. This paper discusses the application of Standards in robot reliability, and surveys the literature of relevant existing standards. A bibliography of relevant Military and NASA standards for reliability and fault tolerance is included.

  13. Non destructive methods applied on condenser tubes of copper alloys, stainless steel and titanium in the various standards and specifications

    International Nuclear Information System (INIS)

    Richter, H.; Heckhaeuser, H.

    1982-01-01

    For condenser tubes the Eddy current method is mostly applied and is found to be a suitable instrument to fulfil the demand to segregate tubes with harmful, injurious defects. Depending on individual special requirements ultrasonic testing may be performed as a additional test to increase the defect detection probability. Most standards applicable for condenser tubes do give preference the exclusive requirements ''test standard'' and ''sensitivity level'' which practically cannot maintain identical or strictly comparable test results relating to different equipment and test data. For a mutual understanding between the various partners involved additional test data should be taken into consideration as to allow clear interpretations of results anticipated. The type of artificial defects specified should take into account, that the exclusive mean of this defect is to establish the sensitivity and not to simulate any natural defect occuring in the tube to be tested. Regarding the physical interactions of EC and UT is recommended to specify bore holes drilled through the wall for EC and longitudinal notches on outside and/or inside surface for UT. For setting purpose the size of bore hole and notch should be selected such as to maintain easy reproducable preparation and sufficient clear and reliable responses

  14. Performance of the standard FAIR equipment controller prototype

    International Nuclear Information System (INIS)

    Rauch, S.; Baer, R.C.; Panschow, W.; Thieme, M.

    2012-01-01

    For the control system of the new FAIR accelerator facility a standard equipment controller, the Scalable Control Unit (SCU), is presently under development. First prototypes have already been tested in real applications. The controller combines an *86 COM Express TM Board and an Altera Arria TM II FPGA. Over a parallel bus interface called the SCU bus, up to 12 slave boards can be controlled. Communication between CPU and FPGA is done by a PCIe link. We discuss the real time behaviour between the Linux OS and the FPGA Hardware. For the test, a Front-End Software Architecture (FESA) class, running under Linux, communicates with the PCIe bridge in the FPGA. Although we are using PCIe only for single 32 bit wide accesses to the FPGA address space, the performance still seems sufficient. The tests showed an average response time to IRQs of 50 μs with a 1.6 GHz Intel Atom CPU. This includes the context change to the FESA user space application and the reply back to the FPGA. Further topics are the bandwidth of the PCIe link for single/burst transfers and the performance of the SCU bus communication. (authors)

  15. International standards for the indoor environment. Where are we and do they apply to Asian countries?

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2003-01-01

    On the international level, ISO (International Organization for Standardization), CEN (European Committee for Standardization) and ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers) are writing and reviewing standards relating to the indoor environment on a regular...... basis. This presentation will focus on the development of standards for the indoor thermal environment and indoor air quality (ventilation). In the future, recommendations for acceptable indoor environments will be specified as classes. This allows for national differences in the requirements as well...... as for designing buildings for different quality levels. Several of these standards have been developed mainly by experts from Europe, North America and Japan. Are there, however, special considerations relating to South-East Asia (lifestyle, outdoor climate, economy) that are not dealt with in these standards...

  16. 40 CFR 428.15 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Standards of performance for new...) EFFLUENT GUIDELINES AND STANDARDS RUBBER MANUFACTURING POINT SOURCE CATEGORY Tire and Inner Tube Plants Subcategory § 428.15 Standards of performance for new sources. The following standards of performance...

  17. Hydrogen Field Test Standard: Laboratory and Field Performance

    Science.gov (United States)

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are

  18. 40 CFR 80.210 - What sulfur standards apply to gasoline downstream from refineries and importers?

    Science.gov (United States)

    2010-07-01

    ... combined with non-S-RGAS for the sole purpose of producing midgrade gasoline. (6) Where S-RGAS is being... of the gasoline. (f) Downstream standards applicable to S-RGAS when produced or imported. (1) The downstream standard applicable to any gasoline classified as S-RGAS when produced or imported shall be...

  19. Using Narratives to Develop Standards for Leaders: Applying an Innovative Approach in Western Australia

    Science.gov (United States)

    Wildy, Helen; Pepper, Coral

    2005-01-01

    Dissatisfaction with long lists of duties as substitutes for standards led to the innovative application of narratives as an alternative approach to the generation and use of standards for school leaders. This paper describes research conducted over nearly a decade in collaboration with the state education authority in Western Australia,…

  20. A primer on standards setting as it applies to surgical education and credentialing.

    Science.gov (United States)

    Cendan, Juan; Wier, Daryl; Behrns, Kevin

    2013-07-01

    Surgical technological advances in the past three decades have led to dramatic reductions in the morbidity associated with abdominal procedures and permanently altered the surgical practice landscape. Significant changes continue apace including surgical robotics, natural orifice-based surgery, and single-incision approaches. These disruptive technologies have on occasion been injurious to patients, and high-stakes assessment before adoption of new technologies would be reasonable. We reviewed the drivers for well-established psychometric techniques available for the standards-setting process. We present a series of examples that are relevant in the surgical domain including standards setting for knowledge and skills assessments. Defensible standards for knowledge and procedural skills will likely become part of surgical clinical practice. Understanding the methodology for determining standards should position the surgical community to assist in the process and lead within their clinical settings as standards are considered that may affect patient safety and physician credentialing.

  1. Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure. 1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions. 1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution. 1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest. 1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this s...

  2. The Influence of Adaptation and Standardization of the Marketing Mix on Performance: a Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Vinícius Andrade Brei

    2011-07-01

    Full Text Available This article analyzes the relationship between strategies of standardization and adaptation of the marketing mix and performance in an international context. We carried out a meta-analysis on a sample of 23 studies published between 1992 and 2010. The sample was analyzed based on measures of the effect size (ES – or the strength of the relation (Wolf, 1986 – between standardization/adaptation and performance. The results suggest the existence of a medium strength (ES ranging from .133 to .209 for the relationship considered. The results support the existence of a positive impact of both marketing mix adaptation and standardization on performance. However, our results suggest that companies should slightly emphasize the marketing mix adaptation (ES mean = .168 instead of standardizing it (ES mean = .134 when entering in a new international market. Results also indicate that, among the adaptation choices, price (ES = .209 should be the first element of the marketing mix to be adapted, followed by promotion (ES = .155, product (ES = .154, and distribution (ES = .141. Finally, we suggest some new research paths, such as the use of quantitative methods to compare degrees of adaptation to be applied to different segments, regions, and sectors, among other suggestions.

  3. Proposed performance standards for the Agricultural Hazardous Occupations Order certification training program.

    Science.gov (United States)

    French, B F; Field, W E; Tormoehlen, R

    2007-07-01

    The performance standards that accompany Gearing Up for Safety, the agricultural production safety training curriculum for youth, were designed to meet the certification testing requirements of the Agricultural Hazardous Occupations Order (AgHOs) certification training program. The AgHOs requires that certain youth who are older than 13 and younger than 16 years of age complete a prescribed training program before being eligible for employment on farms to perform certain tasks considered hazardous. These training resources will be available for implementation and can be accessed by contacting the second author. To our knowledge, up until this time, few, if any, standardized testing procedures or instruments have had the necessary psychometric evidence to support use of the resulting scores to assess the readiness of youth to meet the basic certification requirements contained in the AgHOs. This article describes the rationale, methods, and key findings from a standard-setting session held to establish minimum passing scores for a proposed testing process. The test will be used as a component of the Gearing Up for Safety certification process for youth workers seeking employment to perform job functions as specified under the AgHOs. Readers may be able to apply this standardized testing process, or similarly accepted processes, to other or future testing and certification projects involving agricultural safety and health.

  4. 34 CFR 369.44 - What wage and hour standards apply to community rehabilitation programs?

    Science.gov (United States)

    2010-07-01

    ... VOCATIONAL REHABILITATION SERVICE PROJECTS What Conditions Must Be Met by a Grantee? § 369.44 What wage and... hour standards must be observed in projects carried out in community rehabilitation programs...

  5. NEURO-FUZZY MODELING APPLIED IN PROGRAM MANAGEMENT TO INCREASE LOCAL PUBLIC ADMINISTRATION PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Adrian-Mihai Zaharia-Radulescu

    2016-07-01

    Full Text Available One of the challenges in local public administration is dealing with an increasing number of competing requests coming from the communities they serve. The traditional approach would be to handle each request as a standalone project and be prioritized according to benefits and budget available. More and more nowadays program management is becoming a standard approach in managing the initiatives of local public administration. Program management approach is itself an enabler for performance in public sector organizations by allowing an organization to better coordinate its efforts and resources in managing a portfolio of projects. This paper aims to present how neuro-fuzzy modeling applied in program management can help an organization to increase its performance. Neuro-fuzzy modeling would lead organizations one step further by allowing them to simulate different scenarios and manage better the risks accompanying their initiatives. The research done by the authors is theoretical and combines knowledge from different areas and a neuro-fuzzy model is proposed and discussed.

  6. 40 CFR 417.85 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.85 Standards of performance for new sources. The following standards of...

  7. [Precautions of physical performance requirements and test methods during product standard drafting process of medical devices].

    Science.gov (United States)

    Song, Jin-Zi; Wan, Min; Xu, Hui; Yao, Xiu-Jun; Zhang, Bo; Wang, Jin-Hong

    2009-09-01

    The major idea of this article is to discuss standardization and normalization for the product standard of medical devices. Analyze the problem related to the physical performance requirements and test methods during product standard drafting process and make corresponding suggestions.

  8. 40 CFR 463.24 - New source performance standards.

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY Cleaning Water Subcategory § 463... standards (i.e., mass of pollutant discharged) calculated by multiplying the average process water usage... process water usage flow rate for the new source cleaning water processes from the permittee. ...

  9. 24 CFR 943.148 - What procurement standards apply to PHAs selecting partners for a joint venture?

    Science.gov (United States)

    2010-04-01

    ... PHAs selecting partners for a joint venture? 943.148 Section 943.148 Housing and Urban Development... VENTURES Subsidiaries, Affiliates, Joint Ventures in Public Housing § 943.148 What procurement standards apply to PHAs selecting partners for a joint venture? (a) The requirements of part 85 of this title are...

  10. 25 CFR 900.42 - What are the general financial management system standards that apply to an Indian tribe carrying...

    Science.gov (United States)

    2010-04-01

    ... HEALTH AND HUMAN SERVICES CONTRACTS UNDER THE INDIAN SELF-DETERMINATION AND EDUCATION ASSISTANCE ACT... standards that apply to an Indian tribe carrying out a self-determination contract? 900.42 Section 900.42... carrying out a self-determination contract? An Indian tribe shall expend and account for contract funds in...

  11. 20 CFR 667.274 - What health and safety standards apply to the working conditions of participants in activities...

    Science.gov (United States)

    2010-04-01

    ... and safety standards apply to the working conditions of participants in activities under title I of... working conditions of participants in activities under title I of WIA? 667.274 Section 667.274 Employees... working conditions of employees are equally applicable to working conditions of participants engaged in...

  12. Science and art of setting performance standards and cutoff scores in kinesiology.

    Science.gov (United States)

    Zhu, Weimo

    2013-12-01

    Setting standards and cutoff scores is essential to any measurement and evaluation practice. Two evaluation frameworks, norm-referenced (NR) and criterion-referenced (CR), have often been used for setting standards. Although setting fitness standards based on the NR evaluation is relatively easy as long as a nationally representative sample can be obtained and regularly updated, it has several limitations-namely, time dependency, population dependence, discouraging low-level performers, and favoring advantaged or punishing disadvantaged individuals. Fortunately, these limitations can be significantly eliminated by employing the CR evaluation, which was introduced to kinesiology by Safrit and colleagues in the 1980s and has been successfully applied to some practical problems (e.g., set health-related fitness standards for FITNESSGRAM). Yet, the CR evaluation has its own challenges, e.g., selecting an appropriate measure for a criterion behavior, when the expected relationship between the criterion behavior and a predictive measure is not clear, and when standards are not consistent among multiple field measures. Some of these challenges can be addressed by employing the latest statistical methods (e.g., test equating). This article provides a comprehensive review of the science and art of setting standards and cutoff scores in kinesiology. After a brief historical overview of the standard-setting practice in kinesiology is presented, a case analysis of a successful CR evaluation, along with related challenges, is described. Lessons learned from past and current practice as well as how to develop a defendable standard are described. Finally, future research needs and directions are outlined.

  13. Applying transpose matrix on advanced encryption standard (AES) for database content

    Science.gov (United States)

    Manurung, E. B. P.; Sitompul, O. S.; Suherman

    2018-03-01

    Advanced Encryption Standard (AES) is a specification for the encryption of electronic data established by the U.S. National Institute of Standards and Technology (NIST) and has been adopted by the U.S. government and is now used worldwide. This paper reports the impact of transpose matrix integration to AES. Transpose matrix implementation on AES is aimed at first stage of chypertext modifications for text based database security so that the confidentiality improves. The matrix is also able to increase the avalanche effect of the cryptography algorithm 4% in average.

  14. 78 FR 38735 - Autopsy Performance Criteria: Standards, Guidelines and Best Practices

    Science.gov (United States)

    2013-06-27

    ... DEPARTMENT OF JUSTICE Office of Justice Programs [OJP (NIJ) Docket No. 1626] Autopsy Performance Criteria: Standards, Guidelines and Best Practices AGENCY: National Institute of Justice, DOJ. ACTION... entitled, ``Autopsy Performance Criteria: Standards, Guidelines and Best Practices''. The opportunity to...

  15. 40 CFR 80.217 - How does a refiner or importer apply for the GPA standards?

    Science.gov (United States)

    2010-07-01

    ... annual average sulfur standard for gasoline produced for use in the GPA for the 2004 through 2006 annual... for gasoline produced for use in the GPA. (d) If EPA finds that a refiner or importer provided false... (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Geographic Phase...

  16. Quality control provisions applied in the preparation and characterization of Pu-bearing PERLA standards

    International Nuclear Information System (INIS)

    Guardini, S.; Guzzi, G.; Mousty, F.; Kuhn, E.; Regge, P. de

    1990-01-01

    This report describes the work carried out at the different laboratories where Pu-bearing samples, intended for use as reference materials for NDA measurements, were prepared and characterized. The standard samples were produced from PuO2 and MOX batches of different nature and are at present stored in the PERLA facility at the Institute for Safety Technology of the JRC Ispra and are available for use. Particular attention is paid to the quality control procedures adopted during the sampling, preparation and analysis of the material, to fulfil the requirements established a priori for NDA standards to be used in Safeguards. The results of the different quality control checks are presented and discussed. The drawings of the containers for the PuO2 and MOX powders and of the special fuel rods for MOX pellets are also presented. This report is intended for use in conjunction with the PERLA STANDARD CERTIFICATES which are issued for each type of material considered, and gives to the user the possibility of tracing all analytical data back to primary standards

  17. The Impact of Standards-Based Reform: Applying Brantlinger's Critique of "Hierarchical Ideologies"

    Science.gov (United States)

    Bacon, Jessica; Ferri, Beth

    2013-01-01

    Brantlinger's [2004b. "Ideologies Discerned, Values Determined: Getting past the Hierarchies of Special Education." In "Ideology and the Politics of (in)Exclusion," edited by L. Ware, 11-31. New York: Peter Lang Publishing] critique of hierarchical ideologies lays bare the logics embedded in standards-based reform. Drawing on…

  18. Applying international standards and guidelines on corporate social responsibility: An action plan

    NARCIS (Netherlands)

    Cramer, J.M.

    2005-01-01

    How can a company start the process of corporate social responsibility in an international context, thereby makinge use of diverse standards and guidelines? This question immediately came to the fore emerged after the start of the programme ‘Corporate social responsibility in international context’

  19. 40 CFR 432.105 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS MEAT AND POULTRY PRODUCTS POINT SOURCE CATEGORY Renderers § 432.105 New source... renderer that does not cure cattle hide as part of the plant operations. If a renderer does cure hide, the...

  20. 40 CFR 440.24 - New Source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Aluminum Ore Subcategory § 440.24 New... pollutants discharged in mine drainage from mines producting bauxite ores shall not exceed: Effluent...

  1. 40 CFR 406.35 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 406.35 Section 406.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... § 406.35 Standards of performance for new sources. The following standards of performance establish the...

  2. 40 CFR 406.45 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 406.45 Section 406.45 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... § 406.45 Standards of performance for new sources. The following standards of performance establish the...

  3. 75 FR 68296 - Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources...

    Science.gov (United States)

    2010-11-05

    ... Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources: Sewage... ``Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources: Sewage... performance standards for new units and emission guidelines for existing units for specific categories of...

  4. 76 FR 18407 - Standards of Performance for New Stationary Sources and Emissions Guidelines for Existing Sources...

    Science.gov (United States)

    2011-04-04

    ... Standards of Performance for New Stationary Sources and Emissions Guidelines for Existing Sources: Hospital... performance standards and emissions guidelines for hospital/medical/infectious waste incinerators by the U.S... amendments to the new source performance standards and emissions guidelines, correcting inadvertent drafting...

  5. Risky Business: Applying Ethical Standards to Social Media Use with Vulnerable Populations

    Directory of Open Access Journals (Sweden)

    Hillary Rose Dolinsky

    2015-07-01

    Full Text Available Social media is changing how those in the helping professions offer clinical, medical, or educational services, provide referrals, administer therapeutic interventions, and conduct research. Non-profits and government organizations working with vulnerable populations need to consider the possibility of ethical mistakes when using social media. A comparison of Facebook strategies used with the National Youth in Transition Database (NYTD mandate to engage and locate current and former youth in the child welfare system was conducted. Facebook practices and strategies were examined based on the National Association of Social Workers (NASW Code of Ethics and the Association of Social Work Boards (ASWB Standards for Technology and Social Work Practice. The ethical standards examined include: obtaining consent, preserving confidentiality, verifying youth identity online, and avoiding disclosure of foster care affiliation. Findings demonstrate the importance of providing guidelines and best practices when adopting social media tools for interacting with vulnerable populations.

  6. Optical high-performance computing: introduction to the JOSA A and Applied Optics feature.

    Science.gov (United States)

    Caulfield, H John; Dolev, Shlomi; Green, William M J

    2009-08-01

    The feature issues in both Applied Optics and the Journal of the Optical Society of America A focus on topics of immediate relevance to the community working in the area of optical high-performance computing.

  7. Embedded Web Technology: Applying World Wide Web Standards to Embedded Systems

    Science.gov (United States)

    Ponyik, Joseph G.; York, David W.

    2002-01-01

    Embedded Systems have traditionally been developed in a highly customized manner. The user interface hardware and software along with the interface to the embedded system are typically unique to the system for which they are built, resulting in extra cost to the system in terms of development time and maintenance effort. World Wide Web standards have been developed in the passed ten years with the goal of allowing servers and clients to intemperate seamlessly. The client and server systems can consist of differing hardware and software platforms but the World Wide Web standards allow them to interface without knowing about the details of system at the other end of the interface. Embedded Web Technology is the merging of Embedded Systems with the World Wide Web. Embedded Web Technology decreases the cost of developing and maintaining the user interface by allowing the user to interface to the embedded system through a web browser running on a standard personal computer. Embedded Web Technology can also be used to simplify an Embedded System's internal network.

  8. Improving performances of the knee replacement surgery process by applying DMAIC principles.

    Science.gov (United States)

    Improta, Giovanni; Balato, Giovanni; Romano, Maria; Ponsiglione, Alfonso Maria; Raiola, Eliana; Russo, Mario Alessandro; Cuccaro, Patrizia; Santillo, Liberatina Carmela; Cesarelli, Mario

    2017-12-01

    The work is a part of a project about the application of the Lean Six Sigma to improve health care processes. A previously published work regarding the hip replacement surgery has shown promising results. Here, we propose an application of the DMAIC (Define, Measure, Analyse, Improve, and Control) cycle to improve quality and reduce costs related to the prosthetic knee replacement surgery by decreasing patients' length of hospital stay (LOS) METHODS: The DMAIC cycle has been adopted to decrease the patients' LOS. The University Hospital "Federico II" of Naples, one of the most important university hospitals in Southern Italy, participated in this study. Data on 148 patients who underwent prosthetic knee replacement between 2010 and 2013 were used. Process mapping, statistical measures, brainstorming activities, and comparative analysis were performed to identify factors influencing LOS and improvement strategies. The study allowed the identification of variables influencing the prolongation of the LOS and the implementation of corrective actions to improve the process of care. The adopted actions reduced the LOS by 42%, from a mean value of 14.2 to 8.3 days (standard deviation also decreased from 5.2 to 2.3 days). The DMAIC approach has proven to be a helpful strategy ensuring a significant decreasing of the LOS. Furthermore, through its implementation, a significant reduction of the average costs of hospital stay can be achieved. Such a versatile approach could be applied to improve a wide range of health care processes. © 2017 John Wiley & Sons, Ltd.

  9. Recommendations for a proposed standard for performing systems analysis

    International Nuclear Information System (INIS)

    LaChance, J.; Whitehead, D.; Drouin, M.

    1998-01-01

    In August 1995, the Nuclear Regulatory Commission (NRC) issued a policy statement proposing improved regulatory decisionmaking by increasing the use of PRA [probabilistic risk assessment] in all regulatory matters to the extent supported by the state-of-the-art in PRA methods and data. A key aspect in using PRA in risk-informed regulatory activities is establishing the appropriate scope and attributes of the PRA. In this regard, ASME decided to develop a consensus PRA Standard. The objective is to develop a PRA Standard such that the technical quality of nuclear plant PRAs will be sufficient to support risk-informed regulatory applications. This paper presents examples recommendations for the systems analysis element of a PRA for incorporation into the ASME PRA Standard

  10. Stereotactically Standard Areas: Applied Mathematics in the Service of Brain Targeting in Deep Brain Stimulation

    Directory of Open Access Journals (Sweden)

    Ioannis N. Mavridis

    2017-12-01

    Full Text Available The concept of stereotactically standard areas (SSAs within human brain nuclei belongs to the knowledge of the modern field of stereotactic brain microanatomy. These are areas resisting the individual variability of the nuclear location in stereotactic space. This paper summarizes the current knowledge regarding SSAs. A mathematical formula of SSAs was recently invented, allowing for their robust, reproducible, and accurate application to laboratory studies and clinical practice. Thus, SSAs open new doors for the application of stereotactic microanatomy to highly accurate brain targeting, which is mainly useful for minimally invasive neurosurgical procedures, such as deep brain stimulation.

  11. Stereotactically Standard Areas: Applied Mathematics in the Service of Brain Targeting in Deep Brain Stimulation.

    Science.gov (United States)

    Mavridis, Ioannis N

    2017-12-11

    The concept of stereotactically standard areas (SSAs) within human brain nuclei belongs to the knowledge of the modern field of stereotactic brain microanatomy. These are areas resisting the individual variability of the nuclear location in stereotactic space. This paper summarizes the current knowledge regarding SSAs. A mathematical formula of SSAs was recently invented, allowing for their robust, reproducible, and accurate application to laboratory studies and clinical practice. Thus, SSAs open new doors for the application of stereotactic microanatomy to highly accurate brain targeting, which is mainly useful for minimally invasive neurosurgical procedures, such as deep brain stimulation.

  12. Current Methods Applied to Biomaterials - Characterization Approaches, Safety Assessment and Biological International Standards.

    Science.gov (United States)

    Oliveira, Justine P R; Ortiz, H Ivan Melendez; Bucio, Emilio; Alves, Patricia Terra; Lima, Mayara Ingrid Sousa; Goulart, Luiz Ricardo; Mathor, Monica B; Varca, Gustavo H C; Lugao, Ademar B

    2018-04-10

    Safety and biocompatibility assessment of biomaterials are themes of constant concern as advanced materials enter the market as well as products manufactured by new techniques emerge. Within this context, this review provides an up-to-date approach on current methods for the characterization and safety assessment of biomaterials and biomedical devices from a physicalchemical to a biological perspective, including a description of the alternative methods in accordance with current and established international standards. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  13. 78 FR 37723 - Laser Products; Proposed Amendment to Performance Standard

    Science.gov (United States)

    2013-06-24

    ... of products that incorporate lasers are compact disc and DVD players, fax machines, fiber optic and... incorporate lasers are compact disc and DVD players, fax machines, fiber optic and free-air communication... additional training costs associated with learning the new standard, but believe estimated costs would be so...

  14. 40 CFR 471.43 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ....0 at all times. (f) Metal powder production atomization wastewater. Subpart D—NSPS Pollutant or... GUIDELINES AND STANDARDS NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY Precious Metals...—Subpart D—NSPS. There shall be no discharge of process wastewater pollutants. (b) Rolling spent emulsions...

  15. 40 CFR 471.53 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ...) Metal powder production floor wash wastewater—Subpart E—NSPS. There shall be no discharge of process... all times. (i) Metal powder production wastewater. Subpart E—NSPS Pollutant or pollutant property... GUIDELINES AND STANDARDS NONFERROUS METALS FORMING AND METAL POWDERS POINT SOURCE CATEGORY Refractory Metals...

  16. 76 FR 65653 - New Source Performance Standards (NSPS) Review

    Science.gov (United States)

    2011-10-24

    ... current within their review cycle, there are also multiple standards in different phases of the review... Rock Plants NN 04/16/1982 (47FR16589) 10/17/2000 3 4 (65FR61760) Polymeric Coating of Supporting VVV 09... whether review of a particular NSPS is necessary during the review cycle. A listing of any NSPS for which...

  17. 40 CFR 420.124 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... subject to this subpart shall not exceed the standards set forth below. (a) Galvanizing, terne coating and... hexavalent chromium shall be applicable only to galvanizing operations which discharge wastewaters from the chromate rinse step. 2 Within the range of 6.0 to 9.0. (2) [Reserved] (b) Galvanizing and other coatings—(1...

  18. 40 CFR 463.14 - New source performance standards.

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY Contact Cooling and Heating Water... pollutant discharged), which are calculated by multiplying the average process water usage flow rate for the... 9.0 at all times. The permit authority will obtain the average process water usage flow rate for the...

  19. 40 CFR 463.34 - New source performance standards.

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY Finishing Water Subcategory § 463... process water usage flow rate for the finishing water processes at a new source times the following... usage flow rate for the new source finishing water processes from the permittee. ...

  20. 40 CFR 440.104 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Copper, Lead, Zinc, Gold, Silver, and... copper, lead, zinc, gold, silver, or molybdenum bearing ores or any combination of these ores from open... discharge of process wastewater to navigable waters from mills that use the froth-flotation process alone...

  1. Applying the EBU R128 loudness standard in live-streaming sound sculptures

    DEFF Research Database (Denmark)

    Højlund, Marie Koldkjær; Riis, Morten S.; Rothmann, Daniel

    2017-01-01

    to preserve a natural sounding dynamic image from the varying sound sources that can be played back under varying conditions, an adaptation of the EBU R128 loudness measurement recommendation, originally developed for levelling non-real-time broadcast material, has been applied. The paper describes the Pure......This paper describes the development of a loudness-based compressor for live audio streams. The need for this device arose while developing the public sound art project The Overheard, which involves mixing together several live audio streams through a web based mixing interface. In order...

  2. Reverse translated and gold standard continuous performance tests predict global cognitive performance in schizophrenia.

    Science.gov (United States)

    Bismark, Andrew W; Thomas, Michael L; Tarasenko, Melissa; Shiluk, Alexandra L; Rackelmann, Sonia Y; Young, Jared W; Light, Gregory A

    2018-04-12

    Attentional dysfunction contributes to functional impairments in schizophrenia (SZ). Sustained attention is typically assessed via continuous performance tasks (CPTs), though many CPTs have limited cross-species translational validity and place demands on additional cognitive domains. A reverse-translated 5-Choice Continuous Performance Task (5C-CPT) for human testing-originally developed for use in rodents-was designed to minimize demands on perceptual, visual learning, processing speed, or working memory functions. To-date, no studies have validated the 5C-CPT against gold standard attentional measures nor evaluated how 5C-CPT scores relate to cognition in SZ. Here we examined the relationship between the 5C-CPT and the CPT-Identical Pairs (CPT-IP), an established and psychometrically robust measure of vigilance from the MATRICS Consensus Cognitive Battery (MCCB) in a sample of SZ patients (n = 35). Relationships to global and individual subdomains of cognition were also assessed. 5C-CPT and CPT-IP measures of performance (d-prime) were strongly correlated (r = 0.60). In a regression model, the 5C-CPT and CPT-IP collectively accounted for 54% of the total variance in MCCB total scores, and 27.6% of overall cognitive variance was shared between the 5C-CPT and CPT-IP. These results indicate that the reverse translated 5C-CPT and the gold standard CPT-IP index a common attentional construct that also significantly overlaps with variance in general cognitive performance. The use of simple, cross-species validated behavioral indices of attentional/cognitive functioning such as the 5C-CPT could accelerate the development of novel generalized pro-cognitive therapeutics for SZ and related neuropsychiatric disorders.

  3. Pad-weighing test performed with standardized bladder volume

    DEFF Research Database (Denmark)

    Lose, G; Rosenkilde, P; Gammelgaard, J

    1988-01-01

    The result of the one-hour pad-weighing test proposed by the International Continence Society has been demonstrated to depend on the urine load during the test. To increase reproducibility of the pad-weighing test by minimizing the influence of variation in urine load the test was done with a sta...... to +/- 24 g between two tests. It is concluded that this setup (i.e., standardized bladder volume) of the one-hour pad-weighing test allows for a more reliable assessment of urinary incontinence for quantitative purposes....... with a standardized bladder volume (50% of the cystometric bladder capacity). Twenty-five female patients with stress or mixed incontinence underwent two separate tests. Test-retest results were highly correlated (r = 0.97, p less than 0.001). Nonetheless, analysis of test-retest differences revealed a variation up...

  4. Are we ready to apply the de minimis concept to standard setting: a historical approach

    International Nuclear Information System (INIS)

    Stannard, J.N.

    1984-01-01

    The pros and cons of the de minimis concept is discussed from a historical point of view. The purpose is first to indicate how long ago many common occupational hazards were recognized and second to conclude that there had to be exposure levels that were essentially trivial, i.e., de minimis. Some aspects of the history of radiation protection are presented. The topics of discussion include: empiricism; the tolerance dose; the maximum permissible exposure dose; as low as possible dose (ALAP) and as low as reasonable achievable (ALARA); and the challenge of the '80s. In the '80s with the strong movement to use risk as a basis for both radiation and chemical standards, the need for adding the concept of a trivial risk has taken hold. Some examples of possible de minimis levels, as well as some of the problems and current activities, are presented

  5. 40 CFR 437.14 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... GUIDELINES AND STANDARDS THE CENTRALIZED WASTE TREATMENT POINT SOURCE CATEGORY Metals Treatment and Recovery....3 Metal Parameters Antimony 0.111 0.0312 Arsenic 0.0993 0.0199 Cadmium 0.782 0.163 Chromium 0.167 0.0522 Cobalt 0.182 0.0703 Copper 0.659 0.216 Lead 1.32 0.283 Mercury 0.000641 0.000246 Nickel 0.794 0...

  6. Thermal stress, human performance, and physical employment standards.

    Science.gov (United States)

    Cheung, Stephen S; Lee, Jason K W; Oksa, Juha

    2016-06-01

    Many physically demanding occupations in both developed and developing economies involve exposure to extreme thermal environments that can affect work capacity and ultimately health. Thermal extremes may be present in either an outdoor or an indoor work environment, and can be due to a combination of the natural or artificial ambient environment, the rate of metabolic heat generation from physical work, processes specific to the workplace (e.g., steel manufacturing), or through the requirement for protective clothing impairing heat dissipation. Together, thermal exposure can elicit acute impairment of work capacity and also chronic effects on health, greatly contributing to worker health risk and reduced productivity. Surprisingly, in most occupations even in developed economies, there are rarely any standards regarding enforced heat or cold safety for workers. Furthermore, specific physical employment standards or accommodations for thermal stressors are rare, with workers commonly tested under near-perfect conditions. This review surveys the major occupational impact of thermal extremes and existing employment standards, proposing guidelines for improvement and areas for future research.

  7. Heterophobia: Subverting Heterosexual Hegemony through Intermedial Applied Performance for Young People

    Science.gov (United States)

    Phillips, Hannah

    2016-01-01

    This article responds to intermediality through a case study of an intermedial applied performance for young people. "Heterophobia," a hybrid fusion of live performance, digital technology, social media and urban street art, aimed to challenge homophobia in schools and online. Intermediality was used as a tool to enhance young people's…

  8. Data Mining Methods Applied to Flight Operations Quality Assurance Data: A Comparison to Standard Statistical Methods

    Science.gov (United States)

    Stolzer, Alan J.; Halford, Carl

    2007-01-01

    In a previous study, multiple regression techniques were applied to Flight Operations Quality Assurance-derived data to develop parsimonious model(s) for fuel consumption on the Boeing 757 airplane. The present study examined several data mining algorithms, including neural networks, on the fuel consumption problem and compared them to the multiple regression results obtained earlier. Using regression methods, parsimonious models were obtained that explained approximately 85% of the variation in fuel flow. In general data mining methods were more effective in predicting fuel consumption. Classification and Regression Tree methods reported correlation coefficients of .91 to .92, and General Linear Models and Multilayer Perceptron neural networks reported correlation coefficients of about .99. These data mining models show great promise for use in further examining large FOQA databases for operational and safety improvements.

  9. Draft American National Standard N42.17A: performance specifications for health physics instrumentation

    International Nuclear Information System (INIS)

    Selby, J.M.

    1984-07-01

    The report describes the history of the development of the N42.17 standard on instrument performance, describes the standard itself and its relationship to other standards, and discusses ways the standards might be used on either a voluntary or semi-voluntary basis

  10. Visual operations management tools applied to the oil pipelines and terminals standardization process: the experience of TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Santiago, Adilson; Ribeiro, Kassandra Senra; Arruda, Daniela Mendonca [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes the process by which visual operations management (VOM) tools were implemented, concerning standards and operational procedures in TRANSPETRO's Oil Pipelines and Terminals Unit. It provides: a brief literature review of visual operations management tools applied to total quality management and the standardization processes; a discussion of the assumptions from the second level of VOM (visual standards) upon which TRANSPETRO's oil pipelines and terminals business processes and operational procedures are based; and a description of the VOM implementation process involving more than 100 employees and one illustrative example of 'Quick Guides' for right-of- way management activities. Finally, it discusses the potential impacts and benefits of using VOM tools in the current practices in TRANSPETRO's Oil Pipelines and Terminals Unit, reinforcing the importance of such visual guides as vital to implement regional and corporate procedures, focusing on the main operational processes. (author)

  11. Visual operations management tools applied to the oil pipelines and terminals standardization process: the experience of TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Maria Fatima Ludovico de [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio/ITUC), Rio de Janeiro, RJ (Brazil). Instituto Tecnologico; Santiago, Adilson; Ribeiro, Kassandra Senra; Arruda, Daniela Mendonca [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper describes the process by which visual operations management (VOM) tools were implemented, concerning standards and operational procedures in TRANSPETRO's Oil Pipelines and Terminals Unit. It provides: a brief literature review of visual operations management tools applied to total quality management and the standardization processes; a discussion of the assumptions from the second level of VOM (visual standards) upon which TRANSPETRO's oil pipelines and terminals business processes and operational procedures are based; and a description of the VOM implementation process involving more than 100 employees and one illustrative example of 'Quick Guides' for right-of- way management activities. Finally, it discusses the potential impacts and benefits of using VOM tools in the current practices in TRANSPETRO's Oil Pipelines and Terminals Unit, reinforcing the importance of such visual guides as vital to implement regional and corporate procedures, focusing on the main operational processes. (author)

  12. 75 FR 63259 - Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources...

    Science.gov (United States)

    2010-10-14

    ... Standards of Performance for New Stationary Sources and Emission Guidelines for Existing Sources: Sewage... performance standards for new units and emission guidelines for existing units for specific categories of... standards and emission guidelines for large municipal waste combustion units, small municipal waste...

  13. 40 CFR 1700.14 - Marine Pollution Control Device (MPCD) Performance Standards. [Reserved

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Marine Pollution Control Device (MPCD... UNIFORM NATIONAL DISCHARGE STANDARDS FOR VESSELS OF THE ARMED FORCES Marine Pollution Control Device (MPCD) Performance Standards § 1700.14 Marine Pollution Control Device (MPCD) Performance Standards. [Reserved] ...

  14. Applying the Australian and New Zealand Risk Management Standard to Information Systems in SMES

    Directory of Open Access Journals (Sweden)

    Robyn Davidson

    2004-11-01

    Full Text Available This paper advocates the use of the Australia/New Zealand Risk Management Standard (SA/SNZ, 1999 in conjunction with of a modified version of Birch and McEvoy’s (1992 Structured Risk Analysis for Information Systems (SRA-IS to identify information systems security risks in SMEs. The use of Internet based commerce by SMEs exposes them to information systems security risks that they are ill equipped to recognise let alone mitigate. Unlike the identification of some business risks, identification of risks associated with information systems requires certain technical expertise. The structure of the existing information system must be understood and modelled before risks can be identified and it is acknowledged that the required technical expertise may not be present in SMEs, thus the involvement of information systems consultants may be necessary. Once the information system has been modelled little information systems expertise is required to complete the analysis, keeping consultant involvement to a minimum and maximising owner/manager involvement.

  15. HEP graphics: Standards and portability versus performance and cost

    International Nuclear Information System (INIS)

    Myers, D.R.

    1989-01-01

    After mentioning the range of applications for which computer graphics is used in high energy physics, some of the characteristics required of graphics hardware are presented, along with a discussion of how well these requirements are likely to be met by the computer industry. Moving on to the topic of software, the status of the more important graphics standards is covered briefly, as well as their evolution in the medium term. The point will be made that HEP, perhaps even more than other areas, has conflicting requirements for graphics systems. The subject is manpower-intensive, and the physics community has to made a trade-off. (orig.)

  16. Standardization of test conditions for gamma camera performance measurement

    International Nuclear Information System (INIS)

    Jordan, K.

    1982-02-01

    The way of measuring gamma camera performance is to use point sources or flood sources in air, often in combination with bar phantoms. This method has nothing in common with the use of a camera in clinical practice. Particularly in the case of low energy emitters, like Tc-99m, the influence of scattered radiation over the performance of cameras is very high. The IEC document 'Characteristics and test conditions of radionuclide imaging devices' is discussed

  17. Experience with NQA-1 quality assurance standards applied to in vitro bioassay

    International Nuclear Information System (INIS)

    Bihl, D.E.; MacLellan, J.A.

    1991-10-01

    On June 1, 1990, the large (about 4000 samples per year) excreta bioassay program at the Hanford Site ceased abruptly when the contract with the bioassay laboratory was terminated. An intense, high-priority effort was begun to replace the services on an interim basis until a new contract could be procured. Despite the urgency to get the excreta bioassay program going again, the Hanford Internal Dosimetry Program was constrained to use only labs that could meet stringent quality assurance (QA) requirements, even during the interim period. The QA requirements were based on NQA-1 with selected additions from the Environmental Protection Agency's QAMS 005/80 (EPA 1983) and the American Society for Testing and Materials' C 1009-83 (ASTM 1984). This constraint was driven both by legal reasons and by the Hanford Site contractors and workers not wanting the quality of the data to be sacrificed. Finding labs that could (1) handle the large throughput, (2) meet the technical requirements, and (3) pass the QA audit proved more difficult than first anticipated. This presentation focuses on the QA requirements that the labs had to meet and how those very broad requirements were applied specifically to excreta bioassay. 5 refs

  18. Experience with NQA-1 quality assurance standards applied to in vitro bioassay

    International Nuclear Information System (INIS)

    Bihl, D.E.; MacLellan, J.A.

    1991-01-01

    On June 1, 1990, the large (about 4,000 samples per year) excreta bioassay program at the Hanford Site ceased abruptly when the contract with the bioassay laboratory was terminated. An intense, high-priority effort was begun to replace the services on an interim basis until a new contract could be procured. Despite the urgency to get the excreta bioassay program going again, the Hanford Internal Dosimetry Program was constrained to use only labs that could meet stringent quality assurance (QA) requirements, even during the interim period. The QA requirements were based on NQA-1 with selected additions from the Environmental Protection Agency's QAMS 005/80 (EPA 1983) and the American Society for Testing and Materials' C 1009-83 (ASTM 1984). This constraint was driven both by legal reasons and by the Hanford Site contractors and workers not wanting the quality of the data to be sacrificed. Finding labs that could (1) handle the large throughput, (2) meet the technical requirements, and (3) pass the QA audit proved more difficult than first anticipated. This presentation focuses on the QA requirements that the labs had to meet and how those very broad requirements were applied specifically to excreta bioassay

  19. 40 CFR 437.45 - New source performance standards (NSPS).

    Science.gov (United States)

    2010-07-01

    ... Conventional Parameters BOD 5 163 53.0 O&G 127 38.0 pH (2) (2) TSS 29.6 11.3 Metal Parameters Antimony 0.111 0... 0.216 Lead 0.350 0.160 Mercury 0.000641 0.000246 Nickel 0.794 0.309 Selenium 0.176 0.0698 Silver 0... following in-plant limitations apply to metal-bearing wastewater containing cyanide: In-Plant Limitations...

  20. Evaluation of standardized and applied variables in predicting treatment outcomes of polytrauma patients.

    Science.gov (United States)

    Aksamija, Goran; Mulabdic, Adi; Rasic, Ismar; Muhovic, Samir; Gavric, Igor

    2011-01-01

    Polytrauma is defined as an injury where they are affected by at least two different organ systems or body, with at least one life-threatening injuries. Given the multilevel model care of polytrauma patients within KCUS are inevitable weaknesses in the management of this category of patients. To determine the dynamics of existing procedures in treatment of polytrauma patients on admission to KCUS, and based on statistical analysis of variables applied to determine and define the factors that influence the final outcome of treatment, and determine their mutual relationship, which may result in eliminating the flaws in the approach to the problem. The study was based on 263 polytrauma patients. Parametric and non-parametric statistical methods were used. Basic statistics were calculated, based on the calculated parameters for the final achievement of research objectives, multicoleration analysis, image analysis, discriminant analysis and multifactorial analysis were used. From the universe of variables for this study we selected sample of n = 25 variables, of which the first two modular, others belong to the common measurement space (n = 23) and in this paper defined as a system variable methods, procedures and assessments of polytrauma patients. After the multicoleration analysis, since the image analysis gave a reliable measurement results, we started the analysis of eigenvalues, that is defining the factors upon which they obtain information about the system solve the problem of the existing model and its correlation with treatment outcome. The study singled out the essential factors that determine the current organizational model of care, which may affect the treatment and better outcome of polytrauma patients. This analysis has shown the maximum correlative relationships between these practices and contributed to development guidelines that are defined by isolated factors.

  1. Standardization of test conditions for gamma camera performance measurement

    International Nuclear Information System (INIS)

    Jordan, K.

    1980-01-01

    The actual way of measuring gamma camera performance is to use point sources or flood sources in air, often in combination with bar phantoms. This method mostly brings best performance parameters for cameras but it has nothing in common with the use of a camera in clinical practice. Particular in the case of low energy emitters, like Tc-99m, the influence of scattered radiation over the performance of cameras is very high. Therefore it is important to have test conditions of radionuclide imaging devices, that will approach as best as practicable the measuring conditions in clinical applications. It is therefore a good news that the International Electrochemical Commission IEC has prepared a draft 'Characteristics and test conditions of radionuclide imaging devices' which is now submitted to the national committees for formal approval under the Six Months' Rule. Some essential points of this document are discussed in the paper. (orig.) [de

  2. Design Performance Standards for Large Scale Wind Farms

    DEFF Research Database (Denmark)

    Gordon, Mark

    2009-01-01

    of connection into the Eastern Australian power system under the Rules and guidelines set out by AEMC and NEMMCO (AEMO). Where applicable some international practices are also mentioned. Standards are designed to serve as a technical envelope under which wind farm proponents design the plant and maintain...... ongoing technical compliance of the plant during its operational lifetime. This report is designed to provide general technical information for the wind farm connection engineer to be aware of during the process of connection, registration and operation of wind power plants interconnected into the HV TSO......’s network. No special NER Rule has been used in this document, however V30 (year 2009) has been used as the latest reference on some of the topics discussed. Care has been taken to emphasise certain wind farm design and connection issues that could be considered throughout different stages of the wind farm...

  3. Overview of the Quality Assurance Program Applied to the Performance Assessment of the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    Pickering, S.Y.

    1999-01-01

    The Waste Isolation Pilot Plant (WIPP) is the first deep geologic repository for radioactive waste disposal in the world to be certified by a regulator. Rigorous, nuclear-industry quality assurance (QA) requirements were imposed by the US Environmental Protection Agency. As the Scientific Advisor to the US Department of Energy, Sandia National Laboratories applied these standards to the experimental studies and performance assessment used in the certification process. The QA program ensured that activities conducted by SNL were traceable, transparent, reviewed, reproducible, and retrievable. As a result, regulators and stakeholders were able to evaluate and ultimately certify and accept the WIPP

  4. Cognitive Fatigue Influences Students’ Performance on Standardized Tests

    DEFF Research Database (Denmark)

    Sievertsen, Hans Henrik; Gino, Francesca; Piovesan, Marco

    2016-01-01

    /10 and 2012/13, we find that, for every hour later in the day, test scores decrease by 0.9% of an SD. In addition, a 20- to 30-minute break improves average test scores. Time of day affects students’ test performance because, over the course of a regular day, students’ mental resources get taxed. Thus...

  5. Improving the road wear performance of heavy vehicles in South Africa using a performance-based standards approach

    CSIR Research Space (South Africa)

    Nordengen, Paul A

    2010-05-01

    Full Text Available of the world to achieve regional harmonisation and effective road use have had limited success. Another approach is to consider performance-based standards (PBS); in this case standards specify the performance required from the operation of a vehicle on a...

  6. Accurate simulation of MPPT methods performance when applied to commercial photovoltaic panels.

    Science.gov (United States)

    Cubas, Javier; Pindado, Santiago; Sanz-Andrés, Ángel

    2015-01-01

    A new, simple, and quick-calculation methodology to obtain a solar panel model, based on the manufacturers' datasheet, to perform MPPT simulations, is described. The method takes into account variations on the ambient conditions (sun irradiation and solar cells temperature) and allows fast MPPT methods comparison or their performance prediction when applied to a particular solar panel. The feasibility of the described methodology is checked with four different MPPT methods applied to a commercial solar panel, within a day, and under realistic ambient conditions.

  7. Accurate Simulation of MPPT Methods Performance When Applied to Commercial Photovoltaic Panels

    Directory of Open Access Journals (Sweden)

    Javier Cubas

    2015-01-01

    Full Text Available A new, simple, and quick-calculation methodology to obtain a solar panel model, based on the manufacturers’ datasheet, to perform MPPT simulations, is described. The method takes into account variations on the ambient conditions (sun irradiation and solar cells temperature and allows fast MPPT methods comparison or their performance prediction when applied to a particular solar panel. The feasibility of the described methodology is checked with four different MPPT methods applied to a commercial solar panel, within a day, and under realistic ambient conditions.

  8. A Note on the Determination of "Acceptable" Performance in Thorndike's Standard of Fair Selection.

    Science.gov (United States)

    Brown, Charles

    1980-01-01

    The determination of acceptable performance in Thorndike's constant ratio standard of fair selection is considered. It is shown that suitable choice of acceptable performance can make any minority-majority selection disparity consistent with Thorndike's standard. A rule for determining acceptable performance which avoids the Petersen-Novick…

  9. Applying a social network analysis (SNA) approach to understanding radiologists' performance in reading mammograms

    Science.gov (United States)

    Tavakoli Taba, Seyedamir; Hossain, Liaquat; Heard, Robert; Brennan, Patrick; Lee, Warwick; Lewis, Sarah

    2017-03-01

    Rationale and objectives: Observer performance has been widely studied through examining the characteristics of individuals. Applying a systems perspective, while understanding of the system's output, requires a study of the interactions between observers. This research explains a mixed methods approach to applying a social network analysis (SNA), together with a more traditional approach of examining personal/ individual characteristics in understanding observer performance in mammography. Materials and Methods: Using social networks theories and measures in order to understand observer performance, we designed a social networks survey instrument for collecting personal and network data about observers involved in mammography performance studies. We present the results of a study by our group where 31 Australian breast radiologists originally reviewed 60 mammographic cases (comprising of 20 abnormal and 40 normal cases) and then completed an online questionnaire about their social networks and personal characteristics. A jackknife free response operating characteristic (JAFROC) method was used to measure performance of radiologists. JAFROC was tested against various personal and network measures to verify the theoretical model. Results: The results from this study suggest a strong association between social networks and observer performance for Australian radiologists. Network factors accounted for 48% of variance in observer performance, in comparison to 15.5% for the personal characteristics for this study group. Conclusion: This study suggest a strong new direction for research into improving observer performance. Future studies in observer performance should consider social networks' influence as part of their research paradigm, with equal or greater vigour than traditional constructs of personal characteristics.

  10. Applying Best Business Practices from Corporate Performance Management to DoD

    Science.gov (United States)

    2013-01-01

    leading or governing large, complex corporations and are experienced in creating reliable solutions to complex management issues guided by best business ...recommendations and effective solutions aimed at improving DoD. Defense Business Board Corporate Performance Management REPORT FY13-03 Task...Group 1 Applying Best Business Practices from Corporate Performance Management to DoD TASK The Deputy Secretary of Defense (DEPSECDEF

  11. Pilot test of ANSI draft standard N13.29 environmental dosimetry -- Performance criteria for testing

    International Nuclear Information System (INIS)

    Klemic, G.; Shebell, P.; Monetti, M.; Raccah, F.; Sengupta, S.

    1998-09-01

    American National Standards Institute Draft N13.29 describes performance tests for environmental radiation dosimetry providers. If approved it would be the first step toward applying the types of performance testing now required in personnel dosimetry to environmental radiation monitoring. The objective of this study was to pilot test the draft standard, before it undergoes final balloting, on a small group of dosimetry providers that were selected to provide a mix of facility types, thermoluminescent dosimeter designs and monitoring program applications. The first phase of the pilot test involved exposing dosimeters to laboratory photon, beta, and x-ray sources at routine and accident dose levels. In the second phase, dosimeters were subjected to ninety days of simulated environmental conditions in an environmental chamber that cycled through extremes of temperature and humidity. Two out of seven participants passed all categories of the laboratory testing phase, and all seven passed the environmental test phase. While some relatively minor deficiencies were uncovered in the course of the pilot test, the results show that draft N13.29 describes useful tests that could be appropriate for environmental dosimetry providers. An appendix to this report contains recommendations that should be addressed by the N13.29 working group before draft N13.29 is submitted for balloting

  12. THE IMPACT OF ENVIRONMENTAL MANAGEMENT SYSTEMS (EMSs AND ISO 14001 STANDARDS ON CORPORATE PERFORMANCE: A SYSTEMATIC LITERATURE REVIEW

    Directory of Open Access Journals (Sweden)

    Dajana Grandic

    2017-02-01

    Full Text Available This paper is based on the systematic literature review method and investigates the impacts of the EMS and ISO 14001 Standards towards corporate performance. Two units are considered through the methodology of research; firm size and market orientation. The evidence comes from the analysed dataset of 19 papers. Aggregated search results show that global firms orientated towards export have a higher probability to achieve product and process innovation than companies who focus primarily on regional and local markets due to higher competition in the global market. Moreover, firms who adopted EMS and ISO 14001 standard have a greater impact on performance, a positive influence on innovation and commitment to the environment related to company targets than those firms who did not apply it. The results of this research could be interesting for both investors and academics to know how the voluntary adoption of these two standards affects corporate performance.

  13. EPA's high-level waste standards and waste package performance

    International Nuclear Information System (INIS)

    Meyers, S.

    1985-01-01

    The seven assurance requirements EPA was considering were these: (1) Disposal systems shall not depend on active institutional controls for more than 100 years after disposal; (2) Long-term disposal system performance should be monitored for a reasonable time as a supplement to other types of protection; (3) Disposal systems shall be marked and their locations recorded in all appropriate government records; (4) Disposal systems shall be designed with several different types of barriers, both natural and engineered; (5) Sites should not be located where scarce or easily accessible resources are located; (6) Site selection should consider the relative isolation offered by potential alternatives; and (7) Wastes shall be recoverable for a reasonable time after disposal. (orig./PW)

  14. A method to evaluate performance reliability of individual subjects in laboratory research applied to work settings.

    Science.gov (United States)

    1978-10-01

    This report presents a method that may be used to evaluate the reliability of performance of individual subjects, particularly in applied laboratory research. The method is based on analysis of variance of a tasks-by-subjects data matrix, with all sc...

  15. Students as Employees: Applying Performance Management Principles in the Management Classroom

    Science.gov (United States)

    Gillespie, Treena L.; Parry, Richard O.

    2009-01-01

    The student-as-employee metaphor emphasizes student accountability and participation in learning and provides instructors with work-oriented methods for creating a productive class environment. The authors propose that the tenets of performance management in work organizations can be applied to the classroom. In particular, they focus on three…

  16. Performance study of the primary standard ionization chamber for deployment of the diagnostic radiology qualities

    International Nuclear Information System (INIS)

    Cardoso, Ricardo de Souza; Bossio, Francisco; Quaresma, Daniel da Silva; Peixoto, Jose Guilherme Pereira

    2013-01-01

    Activities radiotherapy, diagnostic radiology and radiation protection, require knowledge of physical and dosimetric parameters, to be applied safely. Aiming to meet demand in Brazil, the National Laboratory of Metrology of Ionising Radiation - LNMRI - is deploying the primary standard for the calibration of secondary standard chambers, used in quality control in hospitals, clinics and industries. (author)

  17. 40 CFR 417.165 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417.165 Standards of performance for new sources. The following standards...) For normal liquid detergent operations the following values pertain: Effluent characteristic Effluent...

  18. Review of Consensus Standard Spectra for Flat Plate and Concentrating Photovoltaic Performance

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D.

    2011-09-01

    Consensus standard reference terrestrial solar spectra are used to establish nameplate ratings for photovoltaic device performance at standard reporting conditions. This report describes reference solar spectra developed in the United States and international consensus standards community which are widely accepted as of this writing (June 2011).

  19. Medicaid management information systems performance standards: Health Care Financing Administration. Notice with comment period.

    Science.gov (United States)

    1981-06-30

    This notice contains performance standards (review elements and factors). We are required by section 1903(r)(6)(E) of the Social Security Act to notify all States of proposed procedures, standards, and other requirements at least one quarter prior to the fiscal year in which the procedures, standards, and other requirements will be used for Medicaid Management Information Systems reapproval reviews. This Notice meets that statutory requirements. By October 1, 1981, we will use the performance standards and existing systems requirements when conducting the annual review of State system performance.

  20. Comparing Performance Standards on the Retention of Words Read Correctly per Minute

    Science.gov (United States)

    Kubina, Richard M., Jr.; Amato, Janelle; Schwilk, Christopher L.; Therrien, William J.

    2008-01-01

    To measure retention of oral reading fluency, three students attending a learning support classroom used a repeating reading strategy with two passages. Each student read one passage to a high performance standard and the other passage to a lower performance standard. Results show it took the students more practice to reach the higher performance…

  1. 40 CFR 450.24 - New source performance standards reflecting the best available demonstrated control technology...

    Science.gov (United States)

    2010-07-01

    ... performance standards reflecting the best available demonstrated control technology (NSPS). Any new source... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards reflecting the best available demonstrated control technology (NSPS). 450.24 Section 450.24 Protection of...

  2. "Circumstance and Proper Timing": Context and the Construction of a Standards Framework for School Principals' Performance.

    Science.gov (United States)

    Louden, William; Wildy, Helen

    1999-01-01

    Professional standards for school principals typically describe an ideal performance in a generalized context. This article describes an alternative method of developing a standards framework, combining qualitative vignettes with probabilistic measurement techniques to provide essential or ideal performance qualities with contextually rich…

  3. Standards Performance Continuum: Development and Validation of a Measure of Effective Pedagogy.

    Science.gov (United States)

    Doherty, R. William; Hilberg, R. Soleste; Epaloose, Georgia; Tharp, Roland G.

    2002-01-01

    Describes the development and validation of the Standards Performance Continuum (SPC) for assessing teacher performance of the Standards for Effective Pedagogy. Three studies involving Florida, California, and New Mexico public school teachers provided evidence of inter-rater reliability, concurrent validity, and criterion-related validity…

  4. 26 CFR 1.23-4 - Performance and quality standards. [Reserved

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 1 2010-04-01 2010-04-01 true Performance and quality standards. [Reserved] 1.23-4 Section 1.23-4 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY INCOME TAX INCOME TAXES Changes in Rates During A Taxable Year § 1.23-4 Performance and quality standards. [Reserved...

  5. 20 CFR 901.20 - Standards of performance of actuarial services.

    Science.gov (United States)

    2010-04-01

    ... services. 901.20 Section 901.20 Employees' Benefits JOINT BOARD FOR THE ENROLLMENT OF ACTUARIES REGULATIONS... Standards of Performance for Enrolled Actuaries § 901.20 Standards of performance of actuarial services. In the discharge of duties required by ERISA of enrolled actuaries with respect to any plan to which the...

  6. Use of performance standards in behavioral health carve-out contracts among Fortune 500 firms.

    Science.gov (United States)

    Merrick, E L; Garnick, D W; Horgan, C M; Goldin, D; Hodgkin, D; Sciegaj, M

    1999-06-25

    To determine the prevalence and nature of performance standards in specialty managed behavioral healthcare contracts among Fortune 500 companies. This was a cross-sectional survey of all companies listed on the Fortune 500 during 1994, 1995, or both. From April 1997 to May 1998 we conducted a mailed survey with phone follow-up. Of the 68% of firms that responded, over one third reported carve-out contracts. The survey focused on whether companies had behavioral health carve-out contracts with specialty vendors and characteristics of these contracts, including the use of performance standards. More than three quarters of the Fortune 500 companies reporting specialty behavioral healthcare contracts used at least one performance standard. Most common were administrative standards (70.2%) and customer service standards (69.4%). About half of the companies used quality standards, whereas only a third used provider-related standards. Most (58.8%) companies using performance standards also specified financial consequences. Larger Fortune 500 firms were significantly more likely to use performance standards. Risk contracts and contracts that included all covered employees were also more likely to include some categories of standards. Administrative and customer service standards may be most common because companies find it easier to specify those standards, especially compared with clinical quality measures. To the extent that employers want to obtain the most value from their behavioral healthcare purchasing, we expect that more will begin to adopt quality standards in their contracts, especially as performance measures become more refined. Reliance on accreditation, however, is an alternative approach for employers.

  7. Performance Values for Non-Destructive Assay (NDA) Technique Applied to Wastes: Evaluation by the ESARDA NDA Working Group

    International Nuclear Information System (INIS)

    Rackham, Jamie; Weber, Anne-Laure; Chard, Patrick

    2012-01-01

    The first evaluation of NDA performance values was undertaken by the ESARDA Working Group for Standards and Non Destructive Assay Techniques and was published in 1993. Almost ten years later in 2002 the Working Group reviewed those values and reported on improvements in performance values and new measurement techniques that had emerged since the original assessment. The 2002 evaluation of NDA performance values did not include waste measurements (although these had been incorporated into the 1993 exercise), because although the same measurement techniques are generally applied, the performance is significantly different compared to the assay of conventional Safeguarded special nuclear material. It was therefore considered more appropriate to perform a separate evaluation of performance values for waste assay. Waste assay is becoming increasingly important within the Safeguards community, particularly since the implementation of the Additional Protocol, which calls for declaration of plutonium and HEU bearing waste in addition to information on existing declared material or facilities. Improvements in the measurement performance in recent years, in particular the accuracy, mean that special nuclear materials can now be accounted for in wastes with greater certainty. This paper presents an evaluation of performance values for the NDA techniques in common usage for the assay of waste containing special nuclear material. The main topics covered by the document are: 1- Techniques for plutonium bearing solid wastes 2- Techniques for uranium bearing solid wastes 3 - Techniques for assay of fissile material in spent fuel wastes. Originally it was intended to include performance values for measurements of uranium and plutonium in liquid wastes; however, as no performance data for liquid waste measurements was obtained it was decided to exclude liquid wastes from this report. This issue of the performance values for waste assay has been evaluated and discussed by the ESARDA

  8. Performance Values for Non-Destructive Assay (NDA) Technique Applied to Wastes: Evaluation by the ESARDA NDA Working Group

    Energy Technology Data Exchange (ETDEWEB)

    Rackham, Jamie [Babcock International Group, Sellafield, Seascale, Cumbria, (United Kingdom); Weber, Anne-Laure [Institut de Radioprotection et de Surete Nucleaire Fontenay-Aux-Roses (France); Chard, Patrick [Canberra, Forss Business and Technology park, Thurso, Caithness (United Kingdom)

    2012-12-15

    The first evaluation of NDA performance values was undertaken by the ESARDA Working Group for Standards and Non Destructive Assay Techniques and was published in 1993. Almost ten years later in 2002 the Working Group reviewed those values and reported on improvements in performance values and new measurement techniques that had emerged since the original assessment. The 2002 evaluation of NDA performance values did not include waste measurements (although these had been incorporated into the 1993 exercise), because although the same measurement techniques are generally applied, the performance is significantly different compared to the assay of conventional Safeguarded special nuclear material. It was therefore considered more appropriate to perform a separate evaluation of performance values for waste assay. Waste assay is becoming increasingly important within the Safeguards community, particularly since the implementation of the Additional Protocol, which calls for declaration of plutonium and HEU bearing waste in addition to information on existing declared material or facilities. Improvements in the measurement performance in recent years, in particular the accuracy, mean that special nuclear materials can now be accounted for in wastes with greater certainty. This paper presents an evaluation of performance values for the NDA techniques in common usage for the assay of waste containing special nuclear material. The main topics covered by the document are: 1- Techniques for plutonium bearing solid wastes 2- Techniques for uranium bearing solid wastes 3 - Techniques for assay of fissile material in spent fuel wastes. Originally it was intended to include performance values for measurements of uranium and plutonium in liquid wastes; however, as no performance data for liquid waste measurements was obtained it was decided to exclude liquid wastes from this report. This issue of the performance values for waste assay has been evaluated and discussed by the ESARDA

  9. An analysis of the intent of environmental standards in the U.S. that apply to waste disposed at the Nevada Test Site

    International Nuclear Information System (INIS)

    Hechanova, A.E.; Mattingly, B.T.; Gitnacht, D.

    2001-01-01

    This paper contains a discussion on the application of U.S. regulatory standards for transuranic waste disposed at the Nevada Test Site. Application of current compliance requirements and regulatory guidance defined for a generic disposal system, although satisfying the 'letter of the law,' is shown to be incompatible with the 'intent of the law' based on a thorough review of the preamble and background documents supporting the regulation. Specifically, the standards that apply to transuranic waste disposal were derived assuming deep geologic disposal and much larger and more hazardous waste forms: irradiated nuclear reactor fuel and high-level radioactive waste. Therefore, key assumptions that underpin the analyses used to justify the standards (e.g., the ground water pathway being considered the only major release mechanism) are inconsistent with the nature of the radionuclide inventory and the intermediate depth of waste emplacement in Greater Confinement Disposal boreholes at the Nevada Test Site. The authors recommend that site specific performance metrics be determined to foster an analysis which is transparent and consistent with U.S. Environmental Protection Agency intent in developing the standards for a generic disposal system. (authors)

  10. A suggested approach toward measuring sorption and applying sorption data to repository performance assessment

    International Nuclear Information System (INIS)

    Rundberg, R.S.

    1992-01-01

    The prediction of radionuclide migration for the purpose of assessing the safety of a nuclear waste repository will be based on a collective knowledge of hydrologic and geochemical properties of the surrounding rock and groundwater. This knowledge along with assumption about the interactions of radionuclides with groundwater and minerals form the scientific basis for a model capable of accurately predicting the repository's performance. Because the interaction of radionuclides in geochemical systems is known to be complicated, several fundamental and empirical approaches to measuring the interaction between radionuclides and the geologic barrier have been developed. The approaches applied to the measurement of sorption involve the use of pure minerals, intact, or crushed rock in dynamic and static experiments. Each approach has its advantages and disadvantages. There is no single best method for providing sorption data for performance assessment models which can be applied without invoking information derived from multiple experiments. 53 refs., 12 figs

  11. Performance values for non destructive assay (NDA) techniques applied to safeguards: the 2002 evaluation by the ESARDA NDA Working Group

    International Nuclear Information System (INIS)

    Guardini, S.

    2003-01-01

    The first evaluation of NDA performance values undertaken by the ESARDA Working Group for Standards and Non Destructive Assay Techniques (WGNDA) was published in 1993. Almost 10 years later the Working Group decided to review those values, to report about improvements and to issue new performance values for techniques which were not applied in the early nineties, or were at that time only emerging. Non-Destructive Assay techniques have become more and more important in recent years, and they are used to a large extent in nuclear material accountancy and control both by operators and control authorities. As a consequence, the performance evaluation for NDA techniques is of particular relevance to safeguards authorities in optimising Safeguards operations and reducing costs. Performance values are important also for NMAC regulators, to define detection levels, limits for anomalies, goal quantities and to negotiate basic audit rules. This paper presents the latest evaluation of ESARDA Performance Values (EPVs) for the most common NDA techniques currently used for the assay of nuclear materials for Safeguards purposes. The main topics covered by the document are: techniques for plutonium bearing materials: PuO 2 and MOX; techniques for U-bearing materials; techniques for U and Pu in liquid form; techniques for spent fuel assay. This issue of the performance values is the result of specific international round robin exercises, field measurements and ad hoc experiments, evaluated and discussed in the ESARDA NDA Working Group. (author)

  12. Analytical Performance Verification of FCS-MPC Applied to Power Electronic Converters

    DEFF Research Database (Denmark)

    Novak, Mateja; Dragicevic, Tomislav; Blaabjerg, Frede

    2017-01-01

    Since the introduction of finite control set model predictive control (FCS-MPC) in power electronics the algorithm has been missing an important aspect that would speed up its implementation in industry: a simple method to verify the algorithm performance. This paper proposes to use a statistical...... model checking (SMC) method for performance evaluation of the algorithm applied to power electronics converters. SMC is simple to implement, intuitive and it requires only an operational model of the system that can be simulated and checked against properties. Device under test for control algorithm...

  13. The First Molecular Identification of an Olive Collection Applying Standard Simple Sequence Repeats and Novel Expressed Sequence Tag Markers.

    Science.gov (United States)

    Mousavi, Soraya; Mariotti, Roberto; Regni, Luca; Nasini, Luigi; Bufacchi, Marina; Pandolfi, Saverio; Baldoni, Luciana; Proietti, Primo

    2017-01-01

    Germplasm collections of tree crop species represent fundamental tools for conservation of diversity and key steps for its characterization and evaluation. For the olive tree, several collections were created all over the world, but only few of them have been fully characterized and molecularly identified. The olive collection of Perugia University (UNIPG), established in the years' 60, represents one of the first attempts to gather and safeguard olive diversity, keeping together cultivars from different countries. In the present study, a set of 370 olive trees previously uncharacterized was screened with 10 standard simple sequence repeats (SSRs) and nine new EST-SSR markers, to correctly and thoroughly identify all genotypes, verify their representativeness of the entire cultivated olive variation, and validate the effectiveness of new markers in comparison to standard genotyping tools. The SSR analysis revealed the presence of 59 genotypes, corresponding to 72 well known cultivars, 13 of them resulting exclusively present in this collection. The new EST-SSRs have shown values of diversity parameters quite similar to those of best standard SSRs. When compared to hundreds of Mediterranean cultivars, the UNIPG olive accessions were splitted into the three main populations (East, Center and West Mediterranean), confirming that the collection has a good representativeness of the entire olive variability. Furthermore, Bayesian analysis, performed on the 59 genotypes of the collection by the use of both sets of markers, have demonstrated their splitting into four clusters, with a well balanced membership obtained by EST respect to standard SSRs. The new OLEST ( Olea expressed sequence tags) SSR markers resulted as effective as the best standard markers. The information obtained from this study represents a high valuable tool for ex situ conservation and management of olive genetic resources, useful to build a common database from worldwide olive cultivar collections

  14. Anodal tDCS applied during multitasking training leads to transferable performance gains.

    Science.gov (United States)

    Filmer, Hannah L; Lyons, Maxwell; Mattingley, Jason B; Dux, Paul E

    2017-10-11

    Cognitive training can lead to performance improvements that are specific to the tasks trained. Recent research has suggested that transcranial direct current stimulation (tDCS) applied during training of a simple response-selection paradigm can broaden performance benefits to an untrained task. Here we assessed the impact of combined tDCS and training on multitasking, stimulus-response mapping specificity, response-inhibition, and spatial attention performance in a cohort of healthy adults. Participants trained over four days with concurrent tDCS - anodal, cathodal, or sham - applied to the left prefrontal cortex. Immediately prior to, 1 day after, and 2 weeks after training, performance was assessed on the trained multitasking paradigm, an untrained multitasking paradigm, a go/no-go inhibition task, and a visual search task. Training combined with anodal tDCS, compared with training plus cathodal or sham stimulation, enhanced performance for the untrained multitasking paradigm and visual search tasks. By contrast, there were no training benefits for the go/no-go task. Our findings demonstrate that anodal tDCS combined with multitasking training can extend to untrained multitasking paradigms as well as spatial attention, but with no extension to the domain of response inhibition.

  15. Performance estimation of Tesla turbine applied in small scale Organic Rankine Cycle (ORC) system

    International Nuclear Information System (INIS)

    Song, Jian; Gu, Chun-wei; Li, Xue-song

    2017-01-01

    Highlights: • One-dimensional model of the Tesla turbine is improved and applied in ORC system. • Working fluid properties and system operating conditions impact efficiency. • The influence of turbine efficiency on ORC system performance is evaluated. • Potential of using Tesla turbine in ORC systems is estimated. - Abstract: Organic Rankine Cycle (ORC) system has been proven to be an effective method for the low grade energy utilization. In small scale applications, the Tesla turbine offers an attractive option for the organic expander if an efficient design can be achieved. The Tesla turbine is simple in structure and is easy to be manufactured. This paper improves the one-dimensional model for the Tesla turbine, which adopts a non-dimensional formulation that identifies the dimensionless parameters that dictates the performance features of the turbine. The model is used to predict the efficiency of a Tesla turbine that is applied in a small scale ORC system. The influence of the working fluid properties and the operating conditions on the turbine performance is evaluated. Thermodynamic analysis of the ORC system with different organic working fluids and under various operating conditions is conducted. The simulation results reveal that the ORC system can generate a considerable net power output. Therefore, the Tesla turbine can be regarded as a potential choice to be applied in small scale ORC systems.

  16. Topically applied standardized aqueous extract of Curcuma longa Linn. suppresses endotoxin-induced uveal inflammation in rats.

    Science.gov (United States)

    Agarwal, Renu; Gupta, S K; Agarwal, Puneet; Srivastava, Sushma

    2013-10-01

    Aqueous extract of C. longa when administered 4 h after induction of E. coli lipopolysaccharide-induced uveitis in rats showed significantly suppressed inflammation with a significantly lower mean clinical grade, histopathological grade and aqueous humor (AH) protein level compared to vehicle treated group. Although, prednisolone group showed significantly lower clinical grade, histopathological grades and AH protein levels compared to C. longa group, TNF-alpha levels did not differ significantly. Moreover, when the aqueous extract was administered starting from 3 days before induction of uveitis, the mean clinical and histopathological grade as well as AH protein and TNF-alpha levels were comparable to C. longa group when treatment was administered 4 h after induction of uveitis. It is concluded that topically applied standardized aqueous extract of C. longa suppresses endotoxin-induced uveitis in rats by reducing TNF-alpha activity.

  17. The status of ANSI N13.11 - The dosimeter performance test standard

    International Nuclear Information System (INIS)

    Sims, C.S.

    1991-01-01

    The standard designated ANSI N13.11 was issued in 1983 and is the basis for the dosimeter performance test associated with the National Voluntary Laboratory Accreditation Program (NVLAP). The standard is important because the Nuclear Regulatory Commission requires that all licensees use personnel dosimeters processed by NVLAP-accredited processors. The standard has undergone review and modifications have been recommended. Historical information concerning the development and utilization of the present standard, ANSI N13.11-1983, is presented. Details associated with the review of the standard (e.g., policy, group selection) are then given. Finally, the modifications recommended by the review group are discussed

  18. Best-Matched Internal Standard Normalization in Liquid Chromatography-Mass Spectrometry Metabolomics Applied to Environmental Samples.

    Science.gov (United States)

    Boysen, Angela K; Heal, Katherine R; Carlson, Laura T; Ingalls, Anitra E

    2018-01-16

    The goal of metabolomics is to measure the entire range of small organic molecules in biological samples. In liquid chromatography-mass spectrometry-based metabolomics, formidable analytical challenges remain in removing the nonbiological factors that affect chromatographic peak areas. These factors include sample matrix-induced ion suppression, chromatographic quality, and analytical drift. The combination of these factors is referred to as obscuring variation. Some metabolomics samples can exhibit intense obscuring variation due to matrix-induced ion suppression, rendering large amounts of data unreliable and difficult to interpret. Existing normalization techniques have limited applicability to these sample types. Here we present a data normalization method to minimize the effects of obscuring variation. We normalize peak areas using a batch-specific normalization process, which matches measured metabolites with isotope-labeled internal standards that behave similarly during the analysis. This method, called best-matched internal standard (B-MIS) normalization, can be applied to targeted or untargeted metabolomics data sets and yields relative concentrations. We evaluate and demonstrate the utility of B-MIS normalization using marine environmental samples and laboratory grown cultures of phytoplankton. In untargeted analyses, B-MIS normalization allowed for inclusion of mass features in downstream analyses that would have been considered unreliable without normalization due to obscuring variation. B-MIS normalization for targeted or untargeted metabolomics is freely available at https://github.com/IngallsLabUW/B-MIS-normalization .

  19. Examining applying high performance genetic data feature selection and classification algorithms for colon cancer diagnosis.

    Science.gov (United States)

    Al-Rajab, Murad; Lu, Joan; Xu, Qiang

    2017-07-01

    This paper examines the accuracy and efficiency (time complexity) of high performance genetic data feature selection and classification algorithms for colon cancer diagnosis. The need for this research derives from the urgent and increasing need for accurate and efficient algorithms. Colon cancer is a leading cause of death worldwide, hence it is vitally important for the cancer tissues to be expertly identified and classified in a rapid and timely manner, to assure both a fast detection of the disease and to expedite the drug discovery process. In this research, a three-phase approach was proposed and implemented: Phases One and Two examined the feature selection algorithms and classification algorithms employed separately, and Phase Three examined the performance of the combination of these. It was found from Phase One that the Particle Swarm Optimization (PSO) algorithm performed best with the colon dataset as a feature selection (29 genes selected) and from Phase Two that the Support Vector Machine (SVM) algorithm outperformed other classifications, with an accuracy of almost 86%. It was also found from Phase Three that the combined use of PSO and SVM surpassed other algorithms in accuracy and performance, and was faster in terms of time analysis (94%). It is concluded that applying feature selection algorithms prior to classification algorithms results in better accuracy than when the latter are applied alone. This conclusion is important and significant to industry and society. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Direct cost analysis of intensive care unit stay in four European countries: applying a standardized costing methodology.

    Science.gov (United States)

    Tan, Siok Swan; Bakker, Jan; Hoogendoorn, Marga E; Kapila, Atul; Martin, Joerg; Pezzi, Angelo; Pittoni, Giovanni; Spronk, Peter E; Welte, Robert; Hakkaart-van Roijen, Leona

    2012-01-01

    The objective of the present study was to measure and compare the direct costs of intensive care unit (ICU) days at seven ICU departments in Germany, Italy, the Netherlands, and the United Kingdom by means of a standardized costing methodology. A retrospective cost analysis of ICU patients was performed from the hospital's perspective. The standardized costing methodology was developed on the basis of the availability of data at the seven ICU departments. It entailed the application of the bottom-up approach for "hotel and nutrition" and the top-down approach for "diagnostics," "consumables," and "labor." Direct costs per ICU day ranged from €1168 to €2025. Even though the distribution of costs varied by cost component, labor was the most important cost driver at all departments. The costs for "labor" amounted to €1629 at department G but were fairly similar at the other departments (€711 ± 115). Direct costs of ICU days vary widely between the seven departments. Our standardized costing methodology could serve as a valuable instrument to compare actual cost differences, such as those resulting from differences in patient case-mix. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  1. Standard test method to determine the performance of tiled roofs to wind-driven rain

    Directory of Open Access Journals (Sweden)

    Sánchez de Rojas, M. I.

    2008-09-01

    Full Text Available The extent to which roof coverings can resist water penetration from the combination of wind and rain, commonly referred to as wind driven rain, is important for the design of roofs. A new project of European Standard prEN 15601 (1 specifies a method of test to determine the performance of the roof covering against wind driven rain. The combined action of wind and rain varies considerably with geographical location of a building and the associated differences in the rain and wind climate. Three windrain conditions and one deluge condition covering Northern Europe Coastal, Central Europe and Southern Europe are specified in the project standard, each subdivided into four wind-speeds and rainfall rates to be applied to the test. The project does not contain information on the level of acceptable performance.Para el diseño de los tejados es importante determinar el punto hasta el cual éstos pueden resistirse a la penetración de agua causada por la combinación de viento y lluvia. Un nuevo proyecto de Norma Europeo prEN 15601 (1 especifica un método de ensayo para determinar el comportamiento del tejado frente a la combinación de viento y lluvia. La acción combinada de viento y lluvia varía considerablemente con la situación geográfica de un edificio y las diferencias asociadas al clima de la lluvia y del viento. El proyecto de norma especifica las condiciones de viento y lluvia y una condición de diluvio para cada una de las tres zonas de Europa: Europa del Norte y Costera, Europa Central y Europa del Sur, cada una subdividida en cuatro condiciones de velocidades de viento y caudal de lluvia para ser aplicadas en los ensayos. El proyecto no contiene la información sobre condiciones aceptables.

  2. Assessing the performance and satisfaction of medical residents utilizing standardized patient versus mannequin-simulated training

    Directory of Open Access Journals (Sweden)

    Alsaad AA

    2017-07-01

    Full Text Available Ali A Alsaad,1 Swetha Davuluri,2 Vandana Y Bhide,3 Amy M Lannen,4 Michael J Maniaci3 1Department of Internal Medicine, Mayo Clinic, 2University of Miami, Coral Gables, 3Division of Hospital Internal Medicine, 4J. Wayne and Delores Barr Weaver Simulation Center, Mayo Clinic, Jacksonville, FL, USA Background: Conducting simulations of rapidly decompensating patients are a key part of internal medicine (IM residency training. Traditionally, mannequins have been the simulation tool used in these scenarios. Objective: To compare IM residents’ performance and assess realism in specific-simulated decompensating patient scenarios using standardized patients (SPs as compared to mannequin. Methods: Nineteen IM residents were randomized to undergo simulations using either a mannequin or an SP. Each resident in the two groups underwent four different simulation scenarios (calcium channel blocker overdose, severe sepsis, severe asthma exacerbation, and acute bacterial meningitis. Residents completed pretest and post-test evaluations as well as a questionnaire to assess the reality perception (realism score. Results: Nine residents completed mannequin-based scenarios, whereas 10 completed SP-based scenarios. Improvement in the post-test scores was seen in both groups. However, there were significantly higher post-test scores achieved with SP simulations in three out of the four scenarios (P=0.01. When compared with the mannequin group, the SP simulation group showed a significantly higher average realism score (P=0.002. Conclusions: Applying SP-based specific-simulation scenarios in IM residency training may result in better performance and a higher sense of a realistic experience by medical residents. Keywords: simulation, standardized patient, satisfaction, mannequin, assessment, resident education

  3. High-performance piezoelectric nanogenerators for self-powered nanosystems: quantitative standards and figures of merit

    Science.gov (United States)

    Wu, Wenzhuo

    2016-03-01

    Harvesting energies from the atmosphere cost-effectively is critical for both addressing worldwide long-term energy needs at the macro-scale, and achieving the sustainable maintenance-free operation of nanodevices at the micro-scale (Wang and Wu 2012 Angew. Chem. Int. Ed. 51 11700-21). Piezoelectric nanogenerator (NG) technology has demonstrated its great application potential in harvesting the ubiquitous and abundant mechanical energy. Despite of the progress made in this rapidly-advancing field, a fundamental understanding and common standard for consistently quantifying and evaluating the performance of the various types of piezoelectric NGs is still lacking. In their recent study Crossley and Kar-Narayan (2015 Nanotechnology 26 344001), systematically investigated dynamical properties of piezoelectric NGs by taking into account the effect of driving mechanism and load frequency on NG performance. They further defined the NGs’ figures of merit as energy harvested normalized by applied strain or stress for NGs under strain-driven or stress-driven conditions, which are commonly seen in the vibrational energy harvesting. This work provides new insight and a feasible approach for consistently evaluating piezoelectric nanomaterials and NG devices, which is important for designing and optimizing nanoscale piezoelectric energy harvesters, as well as promoting their applications in emerging areas e.g. the internet of things, wearable devices, and self-powered nanosystems.

  4. The radiation performance standard. A presentation model for ionizing radiation in the living environment

    International Nuclear Information System (INIS)

    Schaap, L.E.J.J.; Bosmans, G.; Van der Graaf, E.R.; Hendriks, Ch.F.

    1998-01-01

    By means of the so-called radiation performance standard (SPN, abbreviated in Dutch) the total radioactivity from building constructions which contributes to the indoor radiation dose can be calculated. The SPN is implemented with related boundary values and is part of the Building Decree ('Bouwbesluit') in the Netherlands. The model, presented in this book, forms the basis of a new Dutch radiation protection standard, to be published by the Dutch Institute for Standardization NEN (formerly NNI). 14 refs

  5. 40 CFR 407.25 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 407.25 Section 407.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE...

  6. 40 CFR 407.35 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 407.35 Section 407.35 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE...

  7. 40 CFR 407.45 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 407.45 Section 407.45 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE...

  8. 40 CFR 407.15 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 407.15 Section 407.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE...

  9. 40 CFR 406.25 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 406.25 Section 406.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GRAIN MILLS POINT SOURCE CATEGORY Corn Dry Milling Subcategory § 406.25...

  10. 40 CFR 406.15 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Standards of performance for new sources. 406.15 Section 406.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GRAIN MILLS POINT SOURCE CATEGORY Corn Wet Milling Subcategory § 406.15...

  11. 40 CFR 421.274 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... times. (e) Sodium hypochlorite filter backwash. NSPS for the Primary Rare Earth Metals Subcategory...) EFFLUENT GUIDELINES AND STANDARDS NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY Primary Rare Earth Metals Subcategory § 421.274 Standards of performance for new sources. Any new source subject to this...

  12. 40 CFR 60.2035 - How are these new source performance standards structured?

    Science.gov (United States)

    2010-07-01

    ... standards structured? 60.2035 Section 60.2035 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... source performance standards contain the eleven major components listed in paragraphs (a) through (k) of this section. (a) Preconstruction siting analysis. (b) Waste management plan. (c) Operator training and...

  13. 30 CFR 820.11 - Performance standards: Anthracite mines in Pennsylvania.

    Science.gov (United States)

    2010-07-01

    ... Pennsylvania. 820.11 Section 820.11 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... STANDARDS-ANTHRACITE MINES IN PENNSYLVANIA § 820.11 Performance standards: Anthracite mines in Pennsylvania. Anthracite mines in Pennsylvania, as specified in section 529 of the Act, shall comply with its approved...

  14. 40 CFR 428.65 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Standards of performance for new sources. 428.65 Section 428.65 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS RUBBER MANUFACTURING POINT SOURCE CATEGORY Medium-Sized General Molded...

  15. A study on the implementation of the performance of electrical products standards

    Energy Technology Data Exchange (ETDEWEB)

    Berkowitz, M A

    1984-03-01

    The Steering Committee on Electrical Products (SCOPEP) has developed a number of performance standards for selected electrical products and product attributes, under the direction of the Canadian Standards Association. Although the development of these standards shows that a successful standards writing process is in place, the initiation and implementation has been achieved by one or more stakeholder groups spearheading the requirement for the standard. As a result, SCOPEP has been unable to achieve its full potential in its role of developing peformance standards for electrical products. A study was undertaken with the aim of developing a strategic plan for SCOPEP which would be supported by marketing and other strategies. The major elements of the strategy include: selecting those products for which the benefits of a standards program significantly outweigh the costs; agreeing on the use of a framework which rigorously evaluates the cost-benefits of developing performance standards; producing a critical mass of products through the selection process so that revenues from label fees will ultimately balance program costs and support a full time SCOPEP secretariat; aggressively marketing the standards in all sectors, using a balanced push-and-pull strategy; and developing a protagonist attitude so that standards programs implemented are credible to all SCOPEP stakeholders. Detailed cost-benefit tables are appended. 11 figs., 18 tabs.

  16. Performance Analysis of a Utility Helicopter with Standard and Advanced Rotors

    National Research Council Canada - National Science Library

    Yeo, Hyeonsoo; Bousman, William G; Johnson, Wayne

    2002-01-01

    Flight test measurements of the performance of the UH-60 Black Hawk helicopter with both standard and advanced rotors are compared with calculations obtained using the comprehensive helicopter analysis CAMRAD II...

  17. Surface Coating of Plastic Parts for Business Machines (Industrial Surface Coating): New Source Performance Standards (NSPS)

    Science.gov (United States)

    Learn more about the new source performance standards (NSPS) for surface coating of plastic parts for business machines by reading the rule summary and history and finding the code of federal regulations as well as related rules.

  18. Responding to hypnotic and nonhypnotic suggestions: performance standards, imaginative suggestibility, and response expectancies.

    Science.gov (United States)

    Meyer, Eric C; Lynn, Steven Jay

    2011-07-01

    This study examined the relative impact of hypnotic inductions and several other variables on hypnotic and nonhypnotic responsiveness to imaginative suggestions. The authors examined how imaginative suggestibility, response expectancies, motivation to respond to suggestions, and hypnotist-induced performance standards affected participants' responses to both hypnotic and nonhypnotic suggestions and their suggestion-related experiences. Suggestions were administered to 5 groups of participants using a test-retest design: (a) stringent performance standards; (b) lenient performance standards; (c) hypnosis test-retest; (d) no-hypnosis test-retest; and (e) no-hypnosis/hypnosis control. The authors found no support for the influence of a hypnotic induction or performance standards on responding to suggestions but found considerable support for the role of imaginative suggestibility and response expectancies in predicting responses to both hypnotic and nonhypnotic suggestions.

  19. Best practices in selecting performance measures and standards for effective asset management.

    Science.gov (United States)

    2011-06-01

    "This report assesses and provides guidance on best practices in performance measurement, management and standards : setting for effective Transportation Asset Management (TAM). The study is conducted through a literature review, a : survey of the 50...

  20. Medicaid program; Medicaid Management Information Systems; performance standards--HCFA. General notice.

    Science.gov (United States)

    1983-05-31

    The purpose of this notice is to respond to the comments we received on the Medicaid Management Information Systems Performance Standards that we published in a notice with comment period on June 30, 1981 (46 FR 33653).

  1. 76 FR 62074 - Proposed Revision of Performance Standards for State Medicaid Fraud Control Units

    Science.gov (United States)

    2011-10-06

    ... familiar with, and adhere to, policies and procedures. In meeting this standard, the following performance... funding permits. E. Through cross-training or by other means, Unit staff receive training on the role and...

  2. Municipal Solid Waste Landfill New Source Performance Standards (NSPS) and Emission Guidelines (EG) -- Questions and Answers

    Science.gov (United States)

    This November 1998 document of questions and answers are provided as a guide for those subject to the new source performance standards (NSPS) or emission guidelines (EG), as well as those implementing the NSPS or EG.

  3. 20 CFR 666.420 - Under what circumstances may a sanction be applied to local areas for poor performance?

    Science.gov (United States)

    2010-04-01

    ... applied to local areas for poor performance? 666.420 Section 666.420 Employees' Benefits EMPLOYMENT AND... sanction be applied to local areas for poor performance? (a) If a local area fails to meet the levels of... achieving poor levels of performance; or (3) Requires other appropriate measures designed to improve the...

  4. Towards a Quantitative Performance Measurement Framework to Assess the Impact of Geographic Information Standards

    Science.gov (United States)

    Vandenbroucke, D.; Van Orshoven, J.; Vancauwenberghe, G.

    2012-12-01

    Over the last decennia, the use of Geographic Information (GI) has gained importance, in public as well as in private sector. But even if many spatial data and related information exist, data sets are scattered over many organizations and departments. In practice it remains difficult to find the spatial data sets needed, and to access, obtain and prepare them for using in applications. Therefore Spatial Data Infrastructures (SDI) haven been developed to enhance the access, the use and sharing of GI. SDIs consist of a set of technological and non-technological components to reach this goal. Since the nineties many SDI initiatives saw light. Ultimately, all these initiatives aim to enhance the flow of spatial data between organizations (users as well as producers) involved in intra- and inter-organizational and even cross-country business processes. However, the flow of information and its re-use in different business processes requires technical and semantic interoperability: the first should guarantee that system components can interoperate and use the data, while the second should guarantee that data content is understood by all users in the same way. GI-standards within the SDI are necessary to make this happen. However, it is not known if this is realized in practice. Therefore the objective of the research is to develop a quantitative framework to assess the impact of GI-standards on the performance of business processes. For that purpose, indicators are defined and tested in several cases throughout Europe. The proposed research will build upon previous work carried out in the SPATIALIST project. It analyzed the impact of different technological and non-technological factors on the SDI-performance of business processes (Dessers et al., 2011). The current research aims to apply quantitative performance measurement techniques - which are frequently used to measure performance of production processes (Anupindi et al., 2005). Key to reach the research objectives

  5. Standards - the common element in providing the safety, quality and performance of the medical practice

    Science.gov (United States)

    Greabu, Mihai

    2009-01-01

    Knowing and applying standards is an opportunity of the years 2007-2008 in any kind of field where a successful activity is intended and this assures a certain way towards competence and quality. The most recent German studies highlighted, to the surprise of the specialists, that standardization holds the second place, after the material means, in the row of the elements considered to be decisive for the success of a business. The existence of standards and the concern for their implementation in the activity provides a high technical and quality level of the products services offered to the clients and the increase in the level of competence of the personnel, who will be able to cope with all the challenges. This need comes from the process of Romania’s accession to the European Union. There are a lot of reasons why standards represent a fundamental part of our daily life. Practically, we are surrounded by standards. Everything is „working” well and it is efficient if the standards used as a base for manufacturing „things” have been correctly developed and applied. Standards open communication channels and commercial channels, promote the understanding of technical products, the compatibility of products and services, facilitate mass production and, most importantly, they are the necessary base for the achievement of the objectives in the fields of health and safety and a better quality of life. The transition towards the global market needs an instrument for the removal of the barriers to the application of the latest discoveries in the field of medical instruments, materials and manual labor. Each medical device, equipment and material used in the Dental and General Medicine is standardized, in fact that leads to their better knowing and provides controllable treatment for manual labor with predictable and repeatable results. This presentation intends to make a survey of some general aspects on standardization as well as a review of the standards in

  6. The impact of laboratory quality assurance standards on laboratory operational performance

    Directory of Open Access Journals (Sweden)

    E Ratseou

    2014-01-01

    Full Text Available It has become a trend for companies to implement and be certified to various quality management systems so as to improve consistency, reliability, and quality of product delivery to customers. The most common quality management systems adopted are the ISO 9000 series of standards for manufacturing and services related organisations, with ISO 17025 and Good Laboratory Practices (GLP standards adopted specifically by laboratories as quality assurance initiatives. There are various reports on the impact of the ISO 9000 series on organisational performance but no studies or reports have been done on the performance of laboratory standards. Therefore this article reports on a study conducted to investigate the impact of ISO 17025 and GLP on the operational performance of both commercial and non-commercial laboratories. A qualitative research study was conducted to examine the impact standards on the aspects of health and safety, supplier selection and performance, human resources, customer satisfaction and profitability of the laboratory. The data collected suggest that there is no difference in laboratory operational performance with or without the standards. In other words it appears that the basic fundamental requirements inherent with laboratories are sufficient to perform both operationally and optimally. This leads to the view that standards are implemented as a customer requirement and not as an operational requirement.

  7. Assessing the accuracy of forecasting: applying standard diagnostic assessment tools to a health technology early warning system.

    Science.gov (United States)

    Simpson, Sue; Hyde, Chris; Cook, Alison; Packer, Claire; Stevens, Andrew

    2004-01-01

    Early warning systems are an integral part of many health technology assessment programs. Despite this finding, to date, there have been no quantitative evaluations of the accuracy of predictions made by these systems. We report a study evaluating the accuracy of predictions made by the main United Kingdom early warning system. As prediction of impact is analogous to diagnosis, a method normally applied to determine the accuracy of diagnostic tests was used. The sensitivity, specificity, and predictive values of the National Horizon Scanning Centre's prediction methods were estimated with reference to an (imperfect) gold standard, that is, expert opinion of impact 3 to 5 years after prediction. The sensitivity of predictions was 71 percent (95 percent confidence interval [CI], 0.36-0.92), and the specificity was 73 percent (95 percent CI, 0.64-0.8). The negative predictive value was 98 percent (95 percent CI, 0.92-0.99), and the positive predictive value was 14 percent (95 percent CI, 0.06-0.3). Forecasting is difficult, but the results suggest that this early warning system's predictions have an acceptable level of accuracy. However, there are caveats. The first is that early warning systems may themselves reduce the impact of a technology, as helping to control adoption and diffusion is their main purpose. The second is that the use of an imperfect gold standard may bias the results. As early warning systems are viewed as an increasingly important component of health technology assessment and decision making, their outcomes must be evaluated. The method used here should be investigated further and the accuracy of other early warning systems explored.

  8. Performance Analysis of a Neuro-PID Controller Applied to a Robot Manipulator

    Directory of Open Access Journals (Sweden)

    Saeed Pezeshki

    2012-11-01

    Full Text Available The performance of robot manipulators with nonadaptive controllers might degrade significantly due to the open loop unstable system and the effect of some uncertainties on the robot model or environment. A novel Neural Network PID controller (NNP is proposed in order to improve the system performance and its robustness. The Neural Network (NN technique is applied to compensate for the effect of the uncertainties of the robot model. With the NN compensator introduced, the system errors and the NN weights with large dispersion are guaranteed to be bounded in the Lyapunov sense. The weights of the NN compensator are adaptively tuned. The simulation results show the effectiveness of the model validation approach and its efficiency to guarantee a stable and accurate trajectory tracking process in the presence of uncertainties.

  9. A comparison of two standard-setting approaches in high-stakes clinical performance assessment using generalizability theory.

    Science.gov (United States)

    Richter Lagha, Regina A; Boscardin, Christy K; May, Win; Fung, Cha-Chi

    2012-08-01

    Scoring clinical assessments in a reliable and valid manner using criterion-referenced standards remains an important issue and directly affects decisions made regarding examinee proficiency. This generalizability study of students' clinical performance examination (CPX) scores examines the reliability of those scores and of their interpretation, particularly according to a newly introduced, "critical actions" criterion-referenced standard and scoring approach. The authors applied a generalizability framework to the performance scores of 477 third-year students attending three different medical schools in 2008. The norm-referenced standard included all station checklist items. The criterion-referenced standard included only those items deemed critical to patient care by a faculty panel. The authors calculated and compared variance components and generalizability coefficients for each standard across six common stations. Norm-referenced scores had moderate generalizability (ρ = 0.51), whereas criterion-referenced scores showed low dependability (φ = 0.20). The estimated 63% of measurement error associated with the person-by-station interaction suggests case specificity. Increasing the number of stations on the CPX from 6 to 24, an impractical solution both for cost and time, would still yield only moderate dependability (φ = 0.50). Though the performance assessment of complex skills, like clinical competence, seems intrinsically valid, careful consideration of the scoring standard and approach is needed to avoid misinterpretation of proficiency. Further study is needed to determine how best to improve the reliability of criterion-referenced scores, by implementing changes to the examination structure, the process of standard-setting, or both.

  10. 76 FR 63878 - New Source Performance Standards Review for Nitric Acid Plants

    Science.gov (United States)

    2011-10-14

    ... technologies. Nitric acid production is also one of the industrial sectors for which ``white papers'' were... standards (NSPS) for nitric acid plants. Nitric acid plants include one or more nitric acid production units. These proposed revisions include a change to the nitrogen oxides (NO X ) emission limit, which applies...

  11. Developments in life cycle assessment applied to evaluate the environmental performance of construction and demolition wastes.

    Science.gov (United States)

    Bovea, M D; Powell, J C

    2016-04-01

    This paper provides a review of the literature that applies the life cycle assessment (LCA) methodology to the assessment of the environmental performance of the life cycle of construction and demolition waste (CDW) management systems. This article is focused on generating a general mapping of the literature and on identifying the best practices in compliance with LCA framework and proposing directions for future LCA studies in this field. The temporal evolution of the research in this field and the aim of the studies have grown in parallel with the legal framework related to waste and energy efficiency of buildings. Most studies have been published in Europe, followed by USA. Asia and Australia, being at an incipient application stage to the rest of the world. Topics related to "LCA of buildings, including their EoL" and "LCA of general CDW management strategies" are the most frequently analysed, followed by "LCA of EoL of construction elements" and "LCA of natural material vs recycled material". Regarding the strategies, recycling off-site and incineration, both combined with landfill for the rejected fractions, are the most commonly applied. Re-use or recycling on-site is the strategy least applied. The key aspect when LCA is applied to evaluate CDW management systems is the need to normalise which processes to include in the system boundary and the functional unit, the use of inventory data adapted to the context of the case study and the definition of a common set of appropriate impact assessment categories. Also, it is important to obtain results disaggregated by unit processes. This will allow the comparison between case studies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Applying the balanced scorecard to local public health performance measurement: deliberations and decisions.

    Science.gov (United States)

    Weir, Erica; d'Entremont, Nadine; Stalker, Shelley; Kurji, Karim; Robinson, Victoria

    2009-05-08

    All aspects of the heath care sector are being asked to account for their performance. This poses unique challenges for local public health units with their traditional focus on population health and their emphasis on disease prevention, health promotion and protection. Reliance on measures of health status provides an imprecise and partial picture of the performance of a health unit. In 2004 the provincial Institute for Clinical Evaluative Sciences based in Ontario, Canada introduced a public-health specific balanced scorecard framework. We present the conceptual deliberations and decisions undertaken by a health unit while adopting the framework. Posing, pondering and answering key questions assisted in applying the framework and developing indicators. Questions such as: Who should be involved in developing performance indicators? What level of performance should be measured? Who is the primary intended audience? Where and how do we begin? What types of indicators should populate the health status and determinants quadrant? What types of indicators should populate the resources and services quadrant? What type of indicators should populate the community engagement quadrant? What types of indicators should populate the integration and responsiveness quadrants? Should we try to link the quadrants? What comparators do we use? How do we move from a baseline report card to a continuous quality improvement management tool? An inclusive, participatory process was chosen for defining and creating indicators to populate the four quadrants. Examples of indicators that populate the four quadrants of the scorecard are presented and key decisions are highlighted that facilitated the process.

  13. Performance and Stability Enhancement of Perovskite-Type Nanomaterials Applied for Carbon Capture Utilizing Oxyfuel Combustion

    Directory of Open Access Journals (Sweden)

    Qiuwan Shen

    2017-02-01

    Full Text Available A new series of Ba-Co-Operovskite-type oxygen carriers has been successfully synthesized by the microwave-assisted sol-gel method and further applied for producing an O2/CO2 mixture gas. The oxygen adsorption/desorption performance of synthesized samples was studied in a fixed-bed reactor system. Effects of A/B-site substitution on the oxygen desorption performance of Ba-Co-O–based perovskites are also included. Furthermore, the effects of operating conditions including the adsorption time and temperature as well as the desorption temperature on oxygen production performance were investigated in detail. The results indicated that BaCoO3-δ exhibited an excellent oxygen desorption performance among the synthesized A/B-site–substituted ACoO3-δ and BaBO3-δ samples, and that the optimal adsorption time, adsorption temperature and desorption temperatureforBaCoO3-δ were determined to be 20min, 850◦Cand850◦C, respectively, in this study.

  14. Applying lessons learned to enhance human performance and reduce human error for ISS operations

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, W.R.

    1998-09-01

    A major component of reliability, safety, and mission success for space missions is ensuring that the humans involved (flight crew, ground crew, mission control, etc.) perform their tasks and functions as required. This includes compliance with training and procedures during normal conditions, and successful compensation when malfunctions or unexpected conditions occur. A very significant issue that affects human performance in space flight is human error. Human errors can invalidate carefully designed equipment and procedures. If certain errors combine with equipment failures or design flaws, mission failure or loss of life can occur. The control of human error during operation of the International Space Station (ISS) will be critical to the overall success of the program. As experience from Mir operations has shown, human performance plays a vital role in the success or failure of long duration space missions. The Department of Energy`s Idaho National Engineering and Environmental Laboratory (INEEL) is developed a systematic approach to enhance human performance and reduce human errors for ISS operations. This approach is based on the systematic identification and evaluation of lessons learned from past space missions such as Mir to enhance the design and operation of ISS. This paper describes previous INEEL research on human error sponsored by NASA and how it can be applied to enhance human reliability for ISS.

  15. Thermal buffering performance of composite phase change materials applied in low-temperature protective garments

    Science.gov (United States)

    Yang, Kai; Jiao, Mingli; Yu, Yuanyuan; Zhu, Xueying; Liu, Rangtong; Cao, Jian

    2017-07-01

    Phase change material (PCM) is increasingly being applied in the manufacturing of functional thermo-regulated textiles and garments. This paper investigated the thermal buffering performance of different composite PCMs which are suitable for the application in functional low-temperature protective garments. First, according to the criteria selecting PCM for functional textiles/garments, three kinds of pure PCM were selected as samples, which were n-hexadecane, n-octadecane and n-eicosane. To get the adjustable phase change temperature range and higher phase change enthalpy, three kinds of composite PCM were prepared using the above pure PCM. To evaluate the thermal buffering performance of different composite PCM samples, the simulated low-temperature experiments were performed in the climate chamber, and the skin temperature variation curves in three different low temperature conditions were obtained. Finally composite PCM samples’ thermal buffering time, thermal buffering capacity and thermal buffering efficiency were calculated. Results show that the comprehensive thermal buffering performance of n-octadecane and n-eicosane composite PCM is the best.

  16. Development of measurement standards for verifying functional performance of surface texture measuring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, A [Life and Industrial Product Development Department Olympus Corporation, 2951 Ishikawa-machi, Hachiouji-shi, Tokyo (Japan); Suzuki, H [Industrial Marketing and Planning Department Olympus Corporation, Shinjyuku Monolith, 3-1 Nishi-Shinjyuku 2-chome, Tokyo (Japan); Yanagi, K, E-mail: a_fujii@ot.olympus.co.jp [Department of Mechanical Engineering, Nagaoka University of Technology, 1603-1 Kamitomioka-machi, Nagaoka-shi, Niigata (Japan)

    2011-08-19

    A new measurement standard is proposed for verifying overall functional performance of surface texture measuring instruments. Its surface is composed of sinusoidal surface waveforms of chirp signals along horizontal cross sections of the material measure. One of the notable features is that the amplitude of each cycle in the chirp signal form is geometrically modulated so that the maximum slope is kept constant. The maximum slope of the chirp-like signal is gradually decreased according to movement in the lateral direction. We fabricated the measurement standard by FIB processing, and it was calibrated by AFM. We tried to evaluate the functional performance of Laser Scanning Microscope by this standard in terms of amplitude response with varying slope angles. As a result, it was concluded that the proposed standard can easily evaluate the performance of surface texture measuring instruments.

  17. Do field position and playing standard influence athlete performance in wheelchair basketball?

    NARCIS (Netherlands)

    de Witte, A.M.H.; Hoozemans, M.J.M.; Berger, M.A.; van der Woude, L.H.V.; Veeger, H.E.J.

    2016-01-01

    Improved understanding of mobility performance in wheelchair basketball is required to increase game performance. The aim of this study was to quantify the wheelchair-athlete activities of players in different field positions and of different playing standard during wheelchair basketball matches.

  18. Evaluating Faculty Work: Expectations and Standards of Faculty Performance in Research Universities

    Science.gov (United States)

    Hardre, Patricia; Cox, Michelle

    2009-01-01

    Expectations and the way they are communicated can influence employees' motivation and performance. Previous research has demonstrated individual effects of workplace climate and individual differences on faculty productivity. The present study focused on the characteristics of institutional performance standards, evaluation processes and…

  19. 30 CFR 827.13 - Coal preparation plants: Interim performance standards.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Coal preparation plants: Interim performance...-COAL PREPARATION PLANTS NOT LOCATED WITHIN THE PERMIT AREA OF A MINE § 827.13 Coal preparation plants: Interim performance standards. (a) Persons operating or who have operated coal preparation plants after...

  20. Performance Characterization of an xy-Stage Applied to Micrometric Laser Direct Writing Lithography

    Directory of Open Access Journals (Sweden)

    Juan Jaramillo

    2017-01-01

    Full Text Available This article concerns the characterization of the stability and performance of a motorized stage used in laser direct writing lithography. The system was built from commercial components and commanded by G-code. Measurements use a pseudo-periodic-pattern (PPP observed by a camera and image processing is based on Fourier transform and phase measurement methods. The results report that the built system has a stability against vibrations determined by peak-valley deviations of 65 nm and 26 nm in the x and y directions, respectively, with a standard deviation of 10 nm in both directions. When the xy-stage is in movement, it works with a resolution of 0.36 μm, which is an acceptable value for most of research and development (R and D microtechnology developments in which the typical feature size used is in the micrometer range.

  1. Performance Characterization of an xy-Stage Applied to Micrometric Laser Direct Writing Lithography.

    Science.gov (United States)

    Jaramillo, Juan; Zarzycki, Artur; Galeano, July; Sandoz, Patrick

    2017-01-31

    This article concerns the characterization of the stability and performance of a motorized stage used in laser direct writing lithography. The system was built from commercial components and commanded by G-code. Measurements use a pseudo-periodic-pattern (PPP) observed by a camera and image processing is based on Fourier transform and phase measurement methods. The results report that the built system has a stability against vibrations determined by peak-valley deviations of 65 nm and 26 nm in the x and y directions, respectively, with a standard deviation of 10 nm in both directions. When the xy-stage is in movement, it works with a resolution of 0.36 μm, which is an acceptable value for most of research and development (R and D) microtechnology developments in which the typical feature size used is in the micrometer range.

  2. CASE STUDIES ON THE ASSESSMENT OF A REAL ESTATE IN TOURISM BY APPLYING THE 2017 PROPERTY VALUATION STANDARDS AS COMPARED TO 2016 GOODS VALUATION STANDARDS

    Directory of Open Access Journals (Sweden)

    ENEA CONSTANTIN

    2017-12-01

    Full Text Available By means of evaluation, in the Romanian legislation, is the value estimation activity, materialized in a document, called an evaluation report, carried out in accordance with the standards specific to this activity and with professional ethics, by an authorized evaluator. By law, the competent authority to organize, coordinate and authorize the evaluation activity in Romania is the National Association of Authorized Assessors in Romania (ANEVAR or the Association, as an autonomous legal entity, Authorized evaluators are part of it. Due to the dynamic nature of the profession of assessor, the Romanian legislation and other professions with an impact on evaluation, evaluation standards require periodic review. The Standards Collection, 2017, is called the 2017 Property Valuation Standards and will enter into force on May 1, 2017. The structure of the standards of the previous edition has been retained in this edition.

  3. Performance of computer-aided detection applied to full-field digital mammography in detection of breast cancers

    International Nuclear Information System (INIS)

    Sadaf, Arifa; Crystal, Pavel; Scaranelo, Anabel; Helbich, Thomas

    2011-01-01

    Objective: The aim of this retrospective study was to evaluate performance of computer-aided detection (CAD) with full-field digital mammography (FFDM) in detection of breast cancers. Materials and Methods: CAD was retrospectively applied to standard mammographic views of 127 cases with biopsy proven breast cancers detected with FFDM (Senographe 2000, GE Medical Systems). CAD sensitivity was assessed in total group of 127 cases and for subgroups based on breast density, mammographic lesion type, mammographic lesion size, histopathology and mode of presentation. Results: Overall CAD sensitivity was 91% (115 of 127 cases). There were no statistical differences (p > 0.1) in CAD detection of cancers in dense breasts 90% (53/59) versus non-dense breasts 91% (62/68). There was statistical difference (p 20 mm 97% (22/23). Conclusion: CAD applied to FFDM showed 100% sensitivity in identifying cancers manifesting as microcalcifications only and high sensitivity 86% (71/83) for other mammographic appearances of cancer. Sensitivity is influenced by lesion size. CAD in FFDM is an adjunct helping radiologist in early detection of breast cancers.

  4. Technical evaluation of draft ANSI Standard N13.30, ''performance criteria for radiobioassay''

    International Nuclear Information System (INIS)

    MacLellan, J.A.; Traub, R.J.

    1986-03-01

    The Pacific Northwest Laboratory (PNL) is conducting a research program to evaluate the appropriateness of criteria in the ANSI draft Standard N13.30, ''Performance Criteria for Radiobioassay.'' The evaluation has progressed parallel with the preparation of the Standard by evaluating the performance of existing bioassay laboratories against the criteria specified. Recommendations for revision of the Standard and implementation of a testing/accreditation program have been formulated based on study results. The current performance testing program includes both in-vivo counting and in-vitro sample measurements. Test criteria specified in the Standard include relative bias, relative precision, and acceptable minimum detectable activity (AMDA). Results to date have indicated that the acceptance criteria in the Standard are appropriate for the existing state of the industry and are achievable by a majority of the participating laboratories. Specific conclusions are that the AMDA criteria are most difficult for the laboratories to achieve; the relative bias criterion is second in difficulty, and the precision criterion presents no problem for the laboratories; most of the participating laboratories can meet the Standard; and failure rates may decrease as the laboratories become more knowledgeable of the performance criteria. 3 refs., 11 figs., 6 tabs

  5. A Systematic Review of Studies Regarding Applying Standardized Patients for Teaching Communication Skills to Medical Students Between 2000 - 2013

    Directory of Open Access Journals (Sweden)

    M Shirazi

    2015-09-01

    Full Text Available Introduction : Standardized patients, people who are prepared to act as patient as if they are factual and proven performance.   Methods : BEME systematic review of the current approach was for the first time. Databases searched in this study, Scopus, Medline Cinahl, Web of science, Eric, Cochrane, Jama, Ebsco. According to the study, the general criteria for inclusion of articles to study 42 papers were accepted for inclusion into the check list. Check list used is taken from the BEME coding sheet that fits certain criteria, it was added to the study objectives and was developed.   Results : 42 Articles entered into the study, all articles were searched using electronic search. According to a Check list design , types of communication skills that have been studied in this way that doctors and patients communicate Article 7 , Article 2 to start the discussion with the patient, listening skills Article 7 , Article 16 verbal communication with the patient, patient 18, article nonverbal communication , such as body movements , eye contact , etc. 7 articles to gather information , to communicate article 5 , article 5 to understand the patient's perspective , article 13 words, bad news patient (e.g. adversity , cancer, etc , articles 10 to empathize with the patient.   Conclusions : Standardized patients as a teaching method and teaching and assessment practices in recent years have been considered. The lack of articles in the area, the possibility of a vacuum in the decisions of the causes that systematic crossings are operating, particularly the kind of BEME and update that due to the growth of the papers in this area, partly to solve this problem will help.

  6. Multidimensional performance characteristics and standard of performance in talented youth field hockey players : A longitudinal study

    NARCIS (Netherlands)

    Elferink-Gemser, Marije T.; Visscher, Chris; Lemmink, Koen A. P. M.; Mulder, Theo

    2007-01-01

    To identify performance characteristics that could help predict future elite field hockey players, we measured the anthropometric, physiological, technical, tactical, and psychological characteristics of 30 elite and 35 sub-elite youth players at the end of three consecutive seasons. The mean age of

  7. Applying Machine Learning and High Performance Computing to Water Quality Assessment and Prediction

    Directory of Open Access Journals (Sweden)

    Ruijian Zhang

    2017-12-01

    Full Text Available Water quality assessment and prediction is a more and more important issue. Traditional ways either take lots of time or they can only do assessments. In this research, by applying machine learning algorithm to a long period time of water attributes’ data; we can generate a decision tree so that it can predict the future day’s water quality in an easy and efficient way. The idea is to combine the traditional ways and the computer algorithms together. Using machine learning algorithms, the assessment of water quality will be far more efficient, and by generating the decision tree, the prediction will be quite accurate. The drawback of the machine learning modeling is that the execution takes quite long time, especially when we employ a better accuracy but more time-consuming algorithm in clustering. Therefore, we applied the high performance computing (HPC System to deal with this problem. Up to now, the pilot experiments have achieved very promising preliminary results. The visualized water quality assessment and prediction obtained from this project would be published in an interactive website so that the public and the environmental managers could use the information for their decision making.

  8. Cameco engineered tailings program: linking applied research with industrial processes for improved tailings performance

    International Nuclear Information System (INIS)

    Kotzer, T.G.

    2010-01-01

    'Full text:' Mine tailings at Cameco's operations are by-products of milling uranium ore having variable concentrations of uranium, metals, oxyanions and trace elements or elements of concern (EOC). Cameco has undertaken an Engineered Tailings (ET) program to optimize tailings performance and minimize environmental EOC impacts, regardless of the milled ore source. Applied geochemical and geotechnical tailings research is key within the ET program. In-situ drilling and experimental programs are used to understand long-term tailings behaviour and help validate source term predictions. Within this, the ET program proactively aids in the development of mill-based processes for production of tailings having improved long-term stability. (author)

  9. Applying the balanced scorecard to local public health performance measurement: deliberations and decisions

    Directory of Open Access Journals (Sweden)

    Kurji Karim

    2009-05-01

    Full Text Available Abstract Background All aspects of the heath care sector are being asked to account for their performance. This poses unique challenges for local public health units with their traditional focus on population health and their emphasis on disease prevention, health promotion and protection. Reliance on measures of health status provides an imprecise and partial picture of the performance of a health unit. In 2004 the provincial Institute for Clinical Evaluative Sciences based in Ontario, Canada introduced a public-health specific balanced scorecard framework. We present the conceptual deliberations and decisions undertaken by a health unit while adopting the framework. Discussion Posing, pondering and answering key questions assisted in applying the framework and developing indicators. Questions such as: Who should be involved in developing performance indicators? What level of performance should be measured? Who is the primary intended audience? Where and how do we begin? What types of indicators should populate the health status and determinants quadrant? What types of indicators should populate the resources and services quadrant? What type of indicators should populate the community engagement quadrant? What types of indicators should populate the integration and responsiveness quadrants? Should we try to link the quadrants? What comparators do we use? How do we move from a baseline report card to a continuous quality improvement management tool? Summary An inclusive, participatory process was chosen for defining and creating indicators to populate the four quadrants. Examples of indicators that populate the four quadrants of the scorecard are presented and key decisions are highlighted that facilitated the process.

  10. ANSI/ASHRAE/IES Standard 90.1-2016 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eley, Charles [Eley and Associates, Hobe Sound, FL (United States)

    2017-09-29

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 is a new feature of the 2016 edition. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

  11. Comparison of exertion required to perform standard and active compression-decompression cardiopulmonary resuscitation.

    Science.gov (United States)

    Shultz, J J; Mianulli, M J; Gisch, T M; Coffeen, P R; Haidet, G C; Lurie, K G

    1995-02-01

    Active compression-decompression (ACD) cardiopulmonary resuscitation (CPR) utilizes a hand-held suction device with a pressure gauge that enables the operator to compress as well as actively decompress the chest. This new CPR method improves hemodynamic and ventilatory parameters when compared with standard CPR. ACD-CPR is easy to perform but may be more labor intensive. The purpose of this study was to quantify and compare the work required to perform ACD and standard CPR. Cardiopulmonary testing was performed on six basic cardiac life support- and ACD-trained St. Paul, MN fire-fighter personnel during performance of 10 min each of ACD and standard CPR on a mannequin equipped with a compression gauge. The order of CPR techniques was determined randomly with > 1 h between each study. Each CPR method was performed at 80 compressions/min (timed with a metronome), to a depth of 1.5-2 inches, and with a 50% duty cycle. Baseline cardiopulmonary measurements were similar at rest prior to performance of both CPR methods. During standard and ACD-CPR, respectively, rate-pressure product was 18.2 +/- 3.0 vs. 23.8 +/- 1.7 (x 1000, P CPR compared with standard CPR. Both methods require subanaerobic energy expenditure and can therefore be sustained for a sufficient length of time by most individuals to optimize resuscitation efforts. Due to the slightly higher work requirement, ACD-CPR may be more difficult to perform compared with standard CPR for long periods of time, particularly by individuals unaccustomed to the workload requirement of CPR, in general.

  12. Microwave-assisted versus conventional decomposition procedures applied to a ceramic potsherd standard reference material by inductively coupled plasma atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulou, D.N.; Zachariadis, G.A.; Anthemidis, A.N.; Tsirliganis, N.C.; Stratis, J.A

    2004-03-03

    Inductively coupled plasma atomic emission spectrometry (ICP-AES) is a powerful, sensitive analytical technique with numerous applications in chemical characterization including that of ancient pottery, mainly due to its multi-element character, and the relatively short time required for the analysis. A critical step in characterization studies of ancient pottery is the selection of a suitable decomposition procedure for the ceramic matrix. The current work presents the results of a comparative study of six decomposition procedures applied on a standard ceramic potsherd reference material, SARM 69. The investigated decomposition procedures included three microwave-assisted decomposition procedures, one wet decomposition (WD) procedure by conventional heating, one combined microwave-assisted and conventional heating WD procedure, and one fusion procedure. Chemical analysis was carried out by ICP-AES. Five major (Si, Al, Fe, Ca, Mg), three minor (Mn, Ba, Ti) and two trace (Cu, Co) elements were determined and compared with their certified values. Quantitation was performed at two different spectral lines for each element and multi-element matrix-matched calibration standards were used. The recovery values for the six decomposition procedures ranged between 75 and 110% with a few notable exceptions. Data were processed statistically in order to evaluate the investigated decomposition procedures in terms of recovery, accuracy and precision, and eventually select the most appropriate one for ancient pottery analysis.

  13. Evaluation of a draft standard on performance specifications for health physics instrumentation - program overview

    International Nuclear Information System (INIS)

    Kathren, R.L.; Selby, J.M.; Kenoyer, J.L.; Swinth, K.L.

    1983-01-01

    The draft ANSI Standard N42.17 on performance specifications for health physics instrumentation was written in 1981 by a task group that included both manufacturers and users of these instruments as well as representation from the regulatory bodies; the second draft of this standard is currently being evaluated by Pacific Northwest Laboratory. Objectives of this project include the evaluation of the applicability and practicality of the proposed standard and the determination of the degree of conformance of a cross-section of currently available commercial instruments to the proposed standard. This standard is being tested against such instruments as ionization chambers. G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. Radiological, electrical, mechanical, safety, and environmental performance criteria are specified and tests to evaluate conformance are detailed. Specific criteria which are discussed in this draft standard include inspection tests (e.g., readout units, scaling and zero set, decontamination, moisture protection, alarm threshold, battery status indication), AC and battery power requirements, alarm reset, stability, geotropism, response time, accuracy, precision, IER, beta, and neutron energy dependence, radiation overloads, angular dependence, extracameral response, nonionizing electromagnetic radiations, magnetic fields, interfering ionizing radiations, and effect of temperature, humidity, ambient pressure, shock, and vibration. The testing procedures were developed with emphasis on the requirements found in ANSI N42.17 with additional criteria from other draft and current ANSI and IEC standards

  14. Applying Required Navigation Performance Concept for Traffic Management of Small Unmanned Aircraft Systems

    Science.gov (United States)

    Jung, Jaewoo; D'Souza, Sarah N.; Johnson, Marcus A.; Ishihara, Abraham K.; Modi, Hemil C.; Nikaido, Ben; Hasseeb, Hashmatullah

    2016-01-01

    In anticipation of a rapid increase in the number of civil Unmanned Aircraft System(UAS) operations, NASA is researching prototype technologies for a UAS Traffic Management (UTM) system that will investigate airspace integration requirements for enabling safe, efficient low-altitude operations. One aspect a UTM system must consider is the correlation between UAS operations (such as vehicles, operation areas and durations), UAS performance requirements, and the risk to people and property in the operational area. This paper investigates the potential application of the International Civil Aviation Organizations (ICAO) Required Navigation Performance (RNP) concept to relate operational risk with trajectory conformance requirements. The approach is to first define a method to quantify operational risk and then define the RNP level requirement as a function of the operational risk. Greater operational risk corresponds to more accurate RNP level, or smaller tolerable Total System Error (TSE). Data from 19 small UAS flights are used to develop and validate a formula that defines this relationship. An approach to assessing UAS-RNP conformance capability using vehicle modeling and wind field simulation is developed to investigate how this formula may be applied in a future UTM system. The results indicate the modeled vehicles flight path is robust to the simulated wind variation, and it can meet RNP level requirements calculated by the formula. The results also indicate how vehicle-modeling fidelity may be improved to adequately verify assessed RNP level.

  15. Applying Importance-Performance Analysis as a Service Quality Measure in Food Service Industry

    Directory of Open Access Journals (Sweden)

    Gwo-Hshiung Tzeng

    2011-09-01

    Full Text Available As the global economy becomes a service oriented economy, food service accounts for over 20% of service revenue, with an annual growth rate of more than 3%. Compared to physical products, service features are invisible, and the production and sale occurs simultaneously. There is not easy to measure the performance of service. Therefore, the service quality of catering services is considered to be an important topic of service management. According Market Intelligence & Consulting Institute (MIC to apply blog text analyzing to point out top 10 restaurants of blog in Taiwan, what it’s popular restaurant in food service industries. This paper attempts to identify both the importance and performance of restaurant service quality in the Taiwan food service industry using the SERVQUAL and IPA model. We can conclude with certainty that three methods (SERVQUAL, IF and IPA are able to explain significant amount of service quality. At the same time, the service quality factors of IPA model had more comprehensive consideration in comparison to those of SERVQUAL and IF.

  16. Technical evaluation of draft ANSI Standard N13.30, ''Performance Criteria for Radiobioassay''

    International Nuclear Information System (INIS)

    MacLellan, J.A.; Traub, R.J.

    1986-01-01

    To evaluate the appropriateness of the draft Standard, a research program, entitled Technical Evaluation of Draft ANSI Standard N13.30, ''Performance Criteria for Radiobioassay,'' was initiated at the Pacific Northwest Laboratory (PNL). This program incorporates a number of tasks including a nationwide, two-round intercomparison study to test the analytical performance of both in-vitro and in-vivo bioassay laboratories and determine their ability to meet the minimum performance criteria specified in the American National Standards Institute (ANSI) draft Standard, and other tasks related to the establishment of an accreditation laboratory. Based on two rounds of in-vitro testing and the in-vivo pilot study, the project staff has concluded that the criteria selected are appropriate for the existing state of the industry and achievable by most participating laboratories. Specific conclusions are as follows: the AMDA criteria are most difficult for the laboratories to achieve, the relative bias criterion is second in difficulty, and the precision criterion presents no problem for the laboratories, most of the participating laboratories can meet the Standard, and failure rates may decrease as the laboratories become knowledgeable of the performance criteria

  17. Applying a new unequally weighted feature fusion method to improve CAD performance of classifying breast lesions

    Science.gov (United States)

    Zargari Khuzani, Abolfazl; Danala, Gopichandh; Heidari, Morteza; Du, Yue; Mashhadi, Najmeh; Qiu, Yuchen; Zheng, Bin

    2018-02-01

    Higher recall rates are a major challenge in mammography screening. Thus, developing computer-aided diagnosis (CAD) scheme to classify between malignant and benign breast lesions can play an important role to improve efficacy of mammography screening. Objective of this study is to develop and test a unique image feature fusion framework to improve performance in classifying suspicious mass-like breast lesions depicting on mammograms. The image dataset consists of 302 suspicious masses detected on both craniocaudal and mediolateral-oblique view images. Amongst them, 151 were malignant and 151 were benign. The study consists of following 3 image processing and feature analysis steps. First, an adaptive region growing segmentation algorithm was used to automatically segment mass regions. Second, a set of 70 image features related to spatial and frequency characteristics of mass regions were initially computed. Third, a generalized linear regression model (GLM) based machine learning classifier combined with a bat optimization algorithm was used to optimally fuse the selected image features based on predefined assessment performance index. An area under ROC curve (AUC) with was used as a performance assessment index. Applying CAD scheme to the testing dataset, AUC was 0.75+/-0.04, which was significantly higher than using a single best feature (AUC=0.69+/-0.05) or the classifier with equally weighted features (AUC=0.73+/-0.05). This study demonstrated that comparing to the conventional equal-weighted approach, using an unequal-weighted feature fusion approach had potential to significantly improve accuracy in classifying between malignant and benign breast masses.

  18. Applying accreditation standards in a self-evaluation process: The experience of Educational Development Center of Tehran University of Medical Sciences

    Directory of Open Access Journals (Sweden)

    A Mirzazadeh

    2016-03-01

    Full Text Available Introduction: Educational Development Centers (EDCs, as the coordinator in education development in Medical Sciences universities, in order to improve their quality should evaluate their activities. In spite of remarkable performance of Tehran University of Medical Sciences (TUMS EDC in previous national rankings, but it faces many challenges and problems. This paper provided the process, results and lessons learned from a self-evaluation experience conducted at TUMS EDC based on accreditation standards. Method: The present study is an Institutional self-evaluation study based on the national accreditation standards of EDCs (2012. Data were gathered using an open-ended questionnaire developed on the basis of the SWOT format. A directional content analysis applied to analyze the data. Results: In total, 84 point of strengths, 87 weaknesses, 15 opportunities, 24 threats and also 99 recommendations for quality improvement were reported. The most important strengths of the center were the existence of an established mechanism regarding research process in education and scholarship of education, holding various faculty development courses and training standardized patient. The most important weaknesses were the lack of specified procedures in some areas such as monitoring the planning and reviewing of educational programs in the field of educational programs and evaluation of empowerment courses. Conclusion: The present evaluation results will be useful in directing future policies of TUMS EDC such as revising its strategic planning. We hope that the current experience can be helpful for administrators in EDCs in the Ministry of Health and Medical Education and also other Medical Sciences Universities.

  19. Performance Based Plastic Design of Concentrically Braced Frame attuned with Indian Standard code and its Seismic Performance Evaluation

    Directory of Open Access Journals (Sweden)

    Sejal Purvang Dalal

    2015-12-01

    Full Text Available In the Performance Based Plastic design method, the failure is predetermined; making it famous throughout the world. But due to lack of proper guidelines and simple stepwise methodology, it is not quite popular in India. In this paper, stepwise design procedure of Performance Based Plastic Design of Concentrically Braced frame attuned with the Indian Standard code has been presented. The comparative seismic performance evaluation of a six storey concentrically braced frame designed using the displacement based Performance Based Plastic Design (PBPD method and currently used force based Limit State Design (LSD method has also been carried out by nonlinear static pushover analysis and time history analysis under three different ground motions. Results show that Performance Based Plastic Design method is superior to the current design in terms of displacement and acceleration response. Also total collapse of the frame is prevented in the PBPD frame.

  20. Interactive anatomical and surgical live stream lectures improve students' academic performance in applied clinical anatomy.

    Science.gov (United States)

    Shiozawa, Thomas; Butz, Benjamin; Herlan, Stephan; Kramer, Andreas; Hirt, Bernhard

    2017-01-01

    Tuebingen's Sectio Chirurgica (TSC) is an innovative, interactive, multimedia, and transdisciplinary teaching method designed to complement dissection courses. The Tuebingen's Sectio Chirurgica (TSC) allows clinical anatomy to be taught via interactive live stream surgeries moderated by an anatomist. This method aims to provide an application-oriented approach to teaching anatomy that offers students a deeper learning experience. A cohort study was devised to determine whether students who participated in the TSC were better able to solve clinical application questions than students who did not participate. A total of 365 students participated in the dissection course during the winter term of the 2012/2013 academic year. The final examination contained 40 standard multiple-choice (S-MC) and 20 clinically-applied multiple-choice (CA-MC) items. The CA-MC items referred to clinical cases but could be answered solely using anatomical knowledge. Students who regularly participated in the TSC answered the CA-MC questions significantly better than the control group (75% and 65%, respectively; P  0.05). The CA-MC questions had a slightly higher level of difficulty than the S-MC questions (0.725 and 0.801, respectively; P = 0.083). The discriminatory power of the items was comparable (S-MC median Pearson correlations: 0.321; CA-MC: 0.283). The TSC successfully teaches the clinical application of anatomical knowledge. Students who attended the TSC in addition to the dissection course were able to answer CA-MC questions significantly better than students who did not attend the TSC. Thus, attending the TSC in addition to the dissection course supported students' clinical learning goals. Anat Sci Educ 10: 46-52. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  1. Applying policy and health effects of air pollution in South Korea: focus on ambient air quality standards

    Science.gov (United States)

    Ha, Jongsik

    2014-01-01

    Objectives South Korea’s air quality standards are insufficient in terms of establishing a procedure for their management. The current system lacks a proper decision-making process and prior evidence is not considered. The purpose of this study is to propose a measure for establishing atmospheric environmental standards in South Korea that will take into consideration the health of its residents. Methods In this paper, the National Ambient Air Quality Standards (NAAQS) of the US was examined in order to suggest ways, which consider health effects, to establish air quality standards in South Korea. Up-to-date research on the health effects of air pollution was then reviewed, and tools were proposed to utilize the key results. This was done in an effort to ensure the reliability of the standards with regard to public health. Results This study showed that scientific research on the health effects of air pollution and the methodology used in the research have contributed significantly to establishing air quality standards. However, as the standards are legally binding, the procedure should take into account the effects on other sectors. Realistically speaking, it is impossible to establish standards that protect an entire population from air pollution. Instead, it is necessary to find a balance between what should be done and what can be done. Conclusions Therefore, establishing air quality standards should be done as part of an evidence-based policy that identifies the health effects of air pollution and takes into consideration political, economic, and social contexts. PMID:25300297

  2. A Gold Standards Approach to Training Instructors to Evaluate Crew Performance

    Science.gov (United States)

    Baker, David P.; Dismukes, R. Key

    2003-01-01

    The Advanced Qualification Program requires that airlines evaluate crew performance in Line Oriented Simulation. For this evaluation to be meaningful, instructors must observe relevant crew behaviors and evaluate those behaviors consistently and accurately against standards established by the airline. The airline industry has largely settled on an approach in which instructors evaluate crew performance on a series of event sets, using standardized grade sheets on which behaviors specific to event set are listed. Typically, new instructors are given a class in which they learn to use the grade sheets and practice evaluating crew performance observed on videotapes. These classes emphasize reliability, providing detailed instruction and practice in scoring so that all instructors within a given class will give similar scores to similar performance. This approach has value but also has important limitations; (1) ratings within one class of new instructors may differ from those of other classes; (2) ratings may not be driven primarily by the specific behaviors on which the company wanted the crews to be scored; and (3) ratings may not be calibrated to company standards for level of performance skill required. In this paper we provide a method to extend the existing method of training instructors to address these three limitations. We call this method the "gold standards" approach because it uses ratings from the company's most experienced instructors as the basis for training rater accuracy. This approach ties the training to the specific behaviors on which the experienced instructors based their ratings.

  3. Evaluation of performance indicators applied to a material recovery facility fed by mixed packaging waste.

    Science.gov (United States)

    Mastellone, Maria Laura; Cremiato, Raffaele; Zaccariello, Lucio; Lotito, Roberta

    2017-06-01

    Most of the integrated systems for municipal solid waste management aim to increase the recycling of secondary materials by means of physical processes including sorting, shredding and reprocessing. Several restrictions prevent from reaching a very high material recycling efficiency: the variability of the composition of new-marketed materials used for packaging production and its shape and complexity are critical issues. The packaging goods are in fact made of different materials (aluminium, polymers, paper, etc.), possibly assembled, having different shape (flat, cylindrical, one-dimensional, etc.), density, colours, optical properties and so on. These aspects limit the effectiveness and efficiency of the sorting and reprocessing plants. The scope of this study was to evaluate the performance of a large scale Material Recovery Facility (MRF) by utilizing data collected during a long period of monitoring. The database resulted from the measured data has been organized in four sections: (1) data related to the amount and type of inlet waste; (2) amount and composition of output products and waste; (3) operating data (such as worked hours for shift, planned and unscheduled maintenance time, setting parameters of the equipment, and energy consumption for shift); (4) economic data (value of each product, disposal price for the produced waste, penalty for non-compliance of products and waste, etc.). A part of this database has been utilized to build an executive dashboard composed by a set of performance indicators suitable to measure the effectiveness and the efficiency of the MRF operations. The dashboard revealed itself as a powerful tool to support managers and engineers in their decisions in respect to the market demand or compliance regulation variation as well as in the designing of the lay-out improvements. The results indicated that the 40% of the input waste was recovered as valuable products and that a large part of these (88%) complied with the standards of

  4. Performance Measurement Implementation Of Minimum Service Standards For Basic Education Based On The Balanced Scorecard

    Directory of Open Access Journals (Sweden)

    Budiman Rusli

    2015-08-01

    Full Text Available Policies Minimum Service Standards for Basic Education has rolled out since 2002 by the minister in accordance with the Decree No. 129a U 2004 About Minimum Service Standards Education is continually updated and lastly Regulation of the Minister of Education and Culture No. 23 of 2013. All of the district government town should achieve the target of achieving 100 per cent in each of the indicators listed in the minimum service standards for the end of 2014. achievement pad on each indicator is just one measure of the performance of the local government department of education. Unfortunately from the announced target for 27 indicators that exist almost all regions including local governments do not reach Tangerang Regency. It is necessary for measuring the performance of local authorities particularly the education department. One performance measure modern enough that measurements can be done that The Balance Scorecard BSc. In the Balanced Scorecard is a management tool contemporare complete measure company performance not only of the financial perspective but also non-financial performance such as Customer Perspective Internal Business Processes and Learning and Growth. This approach is actually ideally suited for multinational companies because this approach requires very expensive but can be used to measure the profit performance of the company in addition to the combination of a long-term strategic and short-strategic. Balanced Scorecard it can also be done in measuring the performance of public sector services as well by modifying a few things so it can be used to measure the performance of the public sector including the Performance Measurement Minimum Service Standards for Basic Education.

  5. Utility and performance relative to consumer product energy efficiency standards. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Coggins, J.L.

    1979-12-14

    An investigation of the relative utility and performance of nine major household consumer products covered by the Energy Policy and Conservation Act is summarized. The objective was to define the terms utility and performance, to recommend methods for quantifying these two concepts, and to recommend an approach for dealing with utility and performance issues in the energy efficiency standards program. The definitions developed are: performance of a consumer product is the objective measure of how well, with the expected level of consumer input (following the manufacturer's instructions for installation and operation), the product does its intended job; and utility of a consumer product is a subjective measure, based on the consumer's perception, of the capability of the product to satisfy human needs. Quantification is based on test procedures and consumer survey methods which are largely already in use by industry. Utility and performance issues are important in product classification for prescribing energy efficiency standards. The recommended approach to utility and performance issues and classification is: prior to setting standards, evaluate utility and performance issues in the most quantitative way allowed by resources and schedules in order to develop classification guidelines. This approach requires no changes in existing Department of Energy test procedures.

  6. Causes of failing the draft ANSI Standard N13.30 radiobioassay performance criterion for minimum detectable amount

    International Nuclear Information System (INIS)

    MacLellan, J.A.

    1990-02-01

    The test methods used for PNL bioassay performance tests were evaluated by comparing the MDA based on performance tests results with MDA calculated by PNL using the bioassay laboratory's own quality control (QC) data. Two in vitro laboratories and two in vivo laboratories were studied and a correlation between the performance test MDA estimates and QC data was demonstrated. However, it was often necessary to examine the QC data to identify important characteristics of the blank distribution that affect the MDA calculation. Since the MDA equation must be based on the specific analysis and calculational methods of the procedure evaluated. Even when the correct MDA equation is applied, the MDA calculated will have a relatively large confidence interval when only a few replicates are used to estimate the standard deviation. For this reason, a relatively precise estimate of the MDA is generally only available when Poisson statistics may be applied. It was concluded that performance testing alone cannot provide all the information necessary to make an accurate estimate of the measurement process MDA. Review of the laboratory's QC data and the entire measurement procedure will be necessary. Specific recommendations for changes to draft ANSI N13.30 ''Performance Criteria for Radiobioassay'' are given. 10 refs., 18 figs., 11 tabs

  7. 40 CFR 80.524 - What sulfur content standard applies to motor vehicle diesel fuel downstream of the refinery or...

    Science.gov (United States)

    2010-07-01

    ... to motor vehicle diesel fuel downstream of the refinery or importer? 80.524 Section 80.524 Protection... FUELS AND FUEL ADDITIVES Motor Vehicle Diesel Fuel; Nonroad, Locomotive, and Marine Diesel Fuel; and ECA Marine Fuel Motor Vehicle Diesel Fuel Standards and Requirements § 80.524 What sulfur content standard...

  8. 40 CFR 80.213 - What alternative sulfur standards and requirements apply to transmix processors and transmix...

    Science.gov (United States)

    2010-07-01

    ... recovers transmix gasoline product (TGP), as defined in § 80.84(a), from transmix through transmix... TGP meets the applicable sulfur standards under § 80.210 or § 80.220, prior to the TGP leaving the... the TGP sulfur is greater than the standard in § 80.210(b), and the transmix processor has product...

  9. Reference Material Properties and Standard Problems to Verify the Fuel Performance Models Ver 1.0

    International Nuclear Information System (INIS)

    Yang, Yong Sik; Kim, Jae Yong; Koo, Yang Hyun

    2010-12-01

    All fuel performance models must be validated by in-pile and out-pile tests. However, the model validation requires much efforts and times to confirm its exactness. In many fields, new performance models and codes are confirmed by code-to-code benchmarking process under simplified standard problem analysis. At present, the DUOS, which is the steady state fuel performance analysis code for dual cooled annular fuel, development project is progressing and new FEM module is developed to analyze the fuel performance during transient period. In addition, the verification process is planning to examine the new models and module's rightness by comparing with commercial finite element analysis such as a ADINA, ABAQUS and ANSYS. This reports contains the result of unification of material properties and establishment of standard problem to verify the newly developed models with commercial FEM code

  10. International performance-oriented packaging standards adopted in the united states

    International Nuclear Information System (INIS)

    McCall, D.L.

    1993-01-01

    On January 1, 1991, the U.S. Department of Transportation (DOT) initiated a transition to adopting a modified version of current international standards for packaging and transporting hazardous materials and hazardous wastes. This transition permits a 5-year phase-in period that will impact all phases of hazardous material transportation including material classification and description, packaging for shipment, and hazard communication standards. These changes are being enacted through the DOT Federal Docket HM-181, 'Performance-Oriented Packaging Standards.' These regulatory standards will have dramatic impact on nearly 5 billion tons of hazardous materials transported within the United States each year. This paper summarizes the principal elements of the new DOT regulations, the latest implementation schedule and impacts on U.S. shipping activities, and discusses outstanding issues that remain to be solved through the next 5 years. (author)

  11. Performances of the New Real Time Tsunami Detection Algorithm applied to tide gauges data

    Science.gov (United States)

    Chierici, F.; Embriaco, D.; Morucci, S.

    2017-12-01

    Real-time tsunami detection algorithms play a key role in any Tsunami Early Warning System. We have developed a new algorithm for tsunami detection (TDA) based on the real-time tide removal and real-time band-pass filtering of seabed pressure time series acquired by Bottom Pressure Recorders. The TDA algorithm greatly increases the tsunami detection probability, shortens the detection delay and enhances detection reliability with respect to the most widely used tsunami detection algorithm, while containing the computational cost. The algorithm is designed to be used also in autonomous early warning systems with a set of input parameters and procedures which can be reconfigured in real time. We have also developed a methodology based on Monte Carlo simulations to test the tsunami detection algorithms. The algorithm performance is estimated by defining and evaluating statistical parameters, namely the detection probability, the detection delay, which are functions of the tsunami amplitude and wavelength, and the occurring rate of false alarms. In this work we present the performance of the TDA algorithm applied to tide gauge data. We have adapted the new tsunami detection algorithm and the Monte Carlo test methodology to tide gauges. Sea level data acquired by coastal tide gauges in different locations and environmental conditions have been used in order to consider real working scenarios in the test. We also present an application of the algorithm to the tsunami event generated by Tohoku earthquake on March 11th 2011, using data recorded by several tide gauges scattered all over the Pacific area.

  12. Measurement of mental attention: Assessing a cognitive component underlying performance on standardized intelligence tests

    OpenAIRE

    Steven J. Howard; Janice Johnson; Juan Pascual-Leone

    2013-01-01

    Despite the widespread use of standardized IQ tests to measure human intelligence, problems with such measures have led some to suggest that better indices may derive from measurement of cognitive processes underlying performance on IQ tests (e.g., working memory capacity). However, measures from both approaches may exhibit performance biases in favour of majority groups, due to the influence of prior learning and experience. Mental attentional (M-) capacity is proposed to be a causal factor ...

  13. Multivariate regression applied to the performance optimization of a countercurrent ultracentrifuge - a preliminary study

    International Nuclear Information System (INIS)

    Migliavacca, Elder; Andrade, Delvonei Alves de

    2004-01-01

    In this work, the least-squares methodology with covariance matrix is applied to determine a data curve fitting in order to obtain a performance function for the separative power δU of a ultracentrifuge as a function of variables that are experimentally controlled. The experimental data refer to 173 experiments on the ultracentrifugation process for uranium isotope separation. The experimental uncertainties related with these independent variables are considered in the calculation of the experimental separative power values, determining an experimental data input covariance matrix. The process control variables, which significantly influence the δU values, are chosen in order to give information on the ultracentrifuge behaviour when submitted to several levels of feed flow F and cut θ . After the model goodness-of-fit validation, a residual analysis is carried out to verify the assumed basis concerning its randomness and independence and mainly the existence of residual heterocedasticity with any regression model variable. The response curves are made relating the separative power with the control variables F and θ, to compare the fitted model with the experimental data and finally to calculate their optimized values. (author)

  14. 40 CFR 421.334 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ... range of 7.5 to 10.0 at all times. (d) SiC14 purification wet air pollution control. NSPS for the... this subpart shall achieve the following new source performance standards: (a) Sand drying wet air... the range of 7.5 to 10.0 at all times. (b) Sand chlorination off-gas wet air pollution control. NSPS...

  15. Evaluation of a performance-based standards approach to heavy vehicle design to reduce pavement wear

    CSIR Research Space (South Africa)

    Nordengen, Paul A

    2013-11-01

    Full Text Available As a result of successful initiatives in Australia, New Zealand and Canada, the introduction of a performance-based standards (PBS) approach in the heavy vehicle sector in South Africa was identified by the Council for Scientific and Industrial...

  16. 40 CFR 51.352 - Basic I/M performance standard.

    Science.gov (United States)

    2010-07-01

    ... following model I/M program inputs and local characteristics, such as vehicle mix and local fuel controls... current version of the EPA mobile source emission model, and shall meet the minimum performance standard... specified in 40 CFR part 85, subpart W. (8) Emission control device inspections. None. (9) Stringency. A 20...

  17. 76 FR 3517 - Standards of Performance for Fossil-Fuel-Fired, Electric Utility, Industrial-Commercial...

    Science.gov (United States)

    2011-01-20

    ... Standards of Performance for Fossil-Fuel-Fired, Electric Utility, Industrial-Commercial-Institutional, and... following: Category NAICS \\1\\ Examples of regulated entities Industry 221112 Fossil fuel-fired electric utility steam generating units. Federal Government 22112 Fossil fuel-fired electric utility steam...

  18. 20 CFR 1001.123 - Performance standards governing the assignment and role of Local Veterans' Employment...

    Science.gov (United States)

    2010-04-01

    ... assignment and role of Local Veterans' Employment Representatives (LVERs). 1001.123 Section 1001.123... Veterans and Eligible Persons § 1001.123 Performance standards governing the assignment and role of Local... one member of each State agency staff, preferably an eligible veteran, shall be designated and...

  19. Performance assessment of select covers and disposal cell compliance with EPA [Environmental Protection Agency] groundwater standards

    International Nuclear Information System (INIS)

    1989-06-01

    This document describes the technical approach to the assessment of the performance of a full component topslope cover, three sideslope covers, and hence the way in which a Uranium Mill Tailings Remedial Action (UMTRA) Project disposal cell complies with the US Environmental Protection Agency (EPA) groundwater protection standards. 4 refs

  20. Raising the Bar on Faculty Productivity: Realigning Performance Standards to Enhance Quality Trajectories

    Science.gov (United States)

    Hardré, Patricia L.

    2014-01-01

    Many universities have observed needs and shared goals that include increasing faculty members' research productivity (in quantity or quality). Strategies for raising faculty performance include revising standards and supporting valued outcomes with rewards and incentives. One college at a research-extensive university received institutional…

  1. Assessing the Promise of Standards-Based Performance Evaluation for Principals: Results from a Randomized Trial

    Science.gov (United States)

    Kimball, Steven Miller; Milanowski, Anthony; McKinney, Sarah A.

    2009-01-01

    Principals (N = 76) in a large western U.S. school district were randomly assigned to be evaluated using either a new standards-based system or to continue with the old system. It was hypothesized that principals evaluated with the new system would report clearer performance expectations, better feedback, greater fairness and system satisfaction,…

  2. Innovations in Setting Performance Standards for K-12 Test-Based Accountability

    Science.gov (United States)

    Huff, Kristen; Plake, Barbara S.

    2010-01-01

    Standard setting is a systematic process that uses a combination of judgmental and empirical procedures to make recommendations about where on the score continuum "cut scores" should be placed. Cut scores divide the score scale into categories consistent with the descriptions of student performance associated with multiple levels of achievement.…

  3. Special Education Professional Standards: How Important Are They in the Context of Teacher Performance Evaluation?

    Science.gov (United States)

    Woolf, Sara B.

    2015-01-01

    Teacher performance evaluation represents a high stakes issue as evidenced by its pivotal emphasis in national and local education reform initiatives and federal policy levers. National, state, and local education leaders continue to experience unprecedented pressure to adopt standardized benchmarks to reflect and link student achievement data to…

  4. 49 CFR 179.400-4 - Insulation system and performance standard.

    Science.gov (United States)

    2010-10-01

    ... specification— (1) Standard Heat Transfer Rate (SHTR), expressed in Btu/day/lb of water capacity, means the rate of heat transfer used for determining the satisfactory performance of the insulation system of a..., whichever is greater. (5) Calculated heat transfer rate. The calculated heat transfer rate (CHTR) is...

  5. 40 CFR 417.155 - Standards of performance for new sources.

    Science.gov (United States)

    2010-07-01

    ...: (a) For normal operation of spray drying towers as defined above, the following values pertain... operation of a spray drying tower, but only when a high rate of wet scrubbing is in operation which produces... Spray Dried Detergents Subcategory § 417.155 Standards of performance for new sources. The following...

  6. Sewage Treatment Plants: Standards of Performance for New Stationary Sources 1977 Final Rule (42 FR 58520)

    Science.gov (United States)

    This document includes a copy of the Federal Register publication of the November 10, 1977 Final Rule for the Standards of Performance of New Stationary Sources for 40 CFR 60 Subparts O. This document is provided curtesy of HeinOnline.

  7. Evaluation of a draft standard on performance specifications for health physics instrumentation: results for environmental tests

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Mashburn, K.R.; Selby, J.M.

    1984-06-01

    Draft ANSI Standard N42.17 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. Evaluation is performed by testing a cross-section of currently available instruments with testing procedures based on specifications of the standard and then determining the degree of conformance to the various elements of the proposed standard. Data will be presented on the performance of a cross-section of beta-gamma survey instruments under various environmental tests. Test results that will be presented include temperature effects, humidity effects, radio frequency (r.f.) susceptibility, ambient pressure effects, vibration effects, and shock effects. Tests performed to date show that most instruments will meet the temperature, humidity, and ambient pressure tests. A large variability is noted among instruments from the same or different vendors. Preliminary r.f. susceptibility tests have shown large artificial responses at some frequencies for specific instruments. The presentation will also include a discussion of procedures used in the testing and weaknesses identified in the proposed standard

  8. 12 CFR 563e.21 - Performance tests, standards, and ratings, in general.

    Science.gov (United States)

    2010-01-01

    ... flexible underwriting standards for loans that benefit low- or moderate-income geographies or individuals... collects and reports the data required for other savings associations under § 563e.42. (4) Strategic plan. The OTS evaluates the performance of a savings association under a strategic plan if the savings...

  9. 30 CFR 903.819 - Special performance standards-Auger mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Special performance standards-Auger mining. 903.819 Section 903.819 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE ARIZONA § 903...

  10. 30 CFR 941.819 - Special performance standards-auger mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Special performance standards-auger mining. 941.819 Section 941.819 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE SOUTH DAKOTA...

  11. 30 CFR 921.819 - Special performance standards-auger mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Special performance standards-auger mining. 921.819 Section 921.819 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE MASSACHUSETTS...

  12. 30 CFR 922.819 - Special performance standards-auger mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Special performance standards-auger mining. 922.819 Section 922.819 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE MICHIGAN...

  13. 30 CFR 937.819 - Special performance standards-auger mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Special performance standards-auger mining. 937.819 Section 937.819 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE OREGON § 937...

  14. 30 CFR 942.819 - Special performance standards-Auger mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Special performance standards-Auger mining. 942.819 Section 942.819 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE TENNESSEE...

  15. 30 CFR 905.819 - Special performance standards-Auger mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Special performance standards-Auger mining. 905.819 Section 905.819 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE CALIFORNIA...

  16. 30 CFR 933.819 - Special performance standards-auger mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Special performance standards-auger mining. 933.819 Section 933.819 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE NORTH...

  17. 30 CFR 910.819 - Special performance standards-auger mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Special performance standards-auger mining. 910.819 Section 910.819 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE GEORGIA § 910...

  18. 30 CFR 912.819 - Special performance standards-auger mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Special performance standards-auger mining. 912.819 Section 912.819 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE IDAHO § 912...

  19. 30 CFR 939.819 - Special performance standards-auger mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Special performance standards-auger mining. 939.819 Section 939.819 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE RHODE ISLAND...

  20. 30 CFR 947.819 - Special performance standards-auger mining.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Special performance standards-auger mining. 947.819 Section 947.819 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING OPERATIONS WITHIN EACH STATE WASHINGTON...

  1. A pro-forma design for car-carriers: Low-speed performance-based standards

    CSIR Research Space (South Africa)

    Benade R, Berman R

    2015-07-01

    Full Text Available the constraints of the pro-forma design met the Level 1 requirements of the low-speed PBS. Future work will ensure compliance with the full set of twelve performance standards. It is estimated that the pro-forma approach as compared to doing full assessments would...

  2. A Proposed Framework for Applying the National Standards of Quality Assurance in Higher Education in Sudan from the Teaching Staff’s Perspective - Faculties of Business Administration

    Directory of Open Access Journals (Sweden)

    Alfatih Alamin Elfaki

    2017-08-01

    Full Text Available This study aimed to clarify the importance of having national standards and their role in achieving quality, as well as establishing a framework for the actual application of national standards in quality assurance so as to achieve quality in higher education institutions. The researchers  followed a descriptive analytical method to achieve the objectives of the study and developed a questionnaire covering primary and secondary variables that have a role in the design of specific models to help in applying the national standards by the Sudanese universities. The questionnaire included one dependent variable; the effective application of national standards of quality assurance in higher education institutions, and the four main variables (independent are: the national standards of quality assurance in higher education in Sudan, the standard of quality assurance, the standard of teaching and learning and the standard of scientific research and publication. The study revealed a number of conclusions: there were statistically significant differences in the extent of familiarity with the  national quality assurance standards in Sudan according to the academic rank of the  faculty members; there were also significant differences in the extent of compliance with the  national quality assurance standards in Sudan according to the academic rank of the faculty members; there was full agreement between the national standards for quality assurance in Sudan and the international standards for quality assurance; and  there were statistically significant differences in that the absence of specific models would have a negative impact on effective application of national standards of quality assurance in higher education in Sudan, according to the academic rank of the faculty members. Keywords: Quality, The program, Standards, University, Total quality management.

  3. Survey and analysis of environmental performance indicators applied to thermoelectric generation styles; Levantamento e analise de indicadores de desempenho ambiental aplicados a empreendimentos termeletricos

    Energy Technology Data Exchange (ETDEWEB)

    Freitas, Bruno Moreno Rodrigo de; Cardoso Junior, Ricardo Abranches Felix [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil)

    2010-07-01

    Country economic growth is proportional bond to it electric generation increasing capacity. Brazil, which has a power matrix predominantly renewable, currently is increasing generation, from thermoelectricity, due, mainly, to major facilities in relation to environmental licensing. Since this new Thermal Power Plants operating, tied to the generation with those ones already installed, will result in environmental impacts that must be properly controlled. Such control should follow the Environmental Performance Evaluation guidance, standardized by ABNT NBR ISO 14031/04. Therefore, the following work presents the main Environmental Performance Indicators applied to several thermoelectric generation styles (Oil, Natural Gas, Diesel, Mineral Coal, Biomass, Waste, Solar and Nuclear). (author)

  4. Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods provide special techniques needed to determine the electrical performance and spectral response of two-terminal, multijunction photovoltaic (PV) devices, both cell and modules. 1.2 These test methods are modifications and extensions of the procedures for single-junction devices defined by Test Methods E948, E1021, and E1036. 1.3 These test methods do not include temperature and irradiance corrections for spectral response and current-voltage (I-V) measurements. Procedures for such corrections are available in Test Methods E948, E1021, and E1036. 1.4 These test methods may be applied to cells and modules intended for concentrator applications. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and ...

  5. Department of Energy standard for the performance testing of personnel dosimetry systems

    International Nuclear Information System (INIS)

    1986-12-01

    This standard is intended to be used in the Department of Energy Laboratory Accreditation Program (DOELAP) for personnel dosimetry systems. It is based on the American National Standards Institute's (ANSI) ''Criteria for Testing Personnel Dosimetry Performance,'' ANSI N13.11-1983, recommendations made to DOE in ''Guidelines for the Calibration of Personnel Dosimeters,'' Pacific Northwest Laboratory (PNL)-4515 and comments received during peer review by DOE and DOE contractor personnel. The recommendations contained in PNL-4515 were based on an evaluation of ANSI N13.11 conducted for the Office of Nuclear Safety, DOE, by PNL. Parts of ANSI N13.11 that did not require modification were used essentially intact in this standard to maintain consistency with nationally recognized standards. Modifications to this standard have resulted from several DOE/DOE contractor reviews and a pilot testing session. An initial peer review by selected DOE and DOE contractor representatives on technical content was conducted in 1983. A review by DOE field offices, program offices, and contractors was conducted in mid-1984. A pilot performance testing session sponsored by the Office of Nuclear Safety was conducted in early 1985 by the Radiological and Environmental Sciences Laboratory, Idaho Falls. Results of the pilot test were reviewed in late 1985 by a DOE and DOE contractor committee. 11 refs., 4 tabs

  6. Performance test for implantation of a primary standard of low energy X-ray beams

    International Nuclear Information System (INIS)

    Cardoso, Ricardo de Souza; Bossio, Francisco; Peixoto, Jose Guilherme P.

    2005-01-01

    The implementation of a standard laboratory of calibration chambers that will serve to radiotherapy activities, radiodiagnosis and radioprotection, depends on the knowledge of physical and dosimetric parameters that characterize the quality of the radiation beam. With the aim of verifying the reliability of the ionizing free-air chamber with variable volume manufactured by Victoreen Instruments, model 481, as a primary standard, a study of the performance of the chamber to x-rays qualities of low energy was developed in this work. These qualities are the ones recommended by 'Bureau International des Poids et Mesures' - BIPM, for daily routine of the calibration service performed by the 'Laboratorio Nacional de Metrologia das Radiacoes Ionizantes - LNMRI/IRD, for calibration of this secondary standard chambers that serve to the control in hospitals, clinics and industries. The results obtained at the present work show that the Victoreen chamber model 481 behaves as a primary standard, being easy to handle and having simple mechanical construction, and showing an expanded uncertainty equal to 0,26%, regarding the quality of the radiation beam of 30 kV. However, some of the equipment used at the present study need to be submitted to a strict routine calibration, in order for the laboratory to be in accordance with the recommendations of the standard ABNT -NBR ISO/IEC 17025 (2003). (author)

  7. Academy of Nutrition and Dietetics: Revised 2017 Standards of Practice and Standards of Professional Performance for Registered Dietitian Nutritionists (Competent, Proficient, and Expert) in Diabetes Care.

    Science.gov (United States)

    Davidson, Patricia; Ross, Tamara; Castor, Chimene

    2018-05-01

    There are 30.3 million people with diabetes and 86 million with prediabetes in the United States, underscoring the growing need for comprehensive diabetes care and nutrition for the management of diabetes and diabetes-related conditions. Management of diabetes is also critical for the prevention of diabetes-related complications such as cardiovascular and renal disease. The Diabetes Care and Education Dietetic Practice Group along with the Academy of Nutrition and Dietetics Quality Management Committee have updated the Standards of Practice (SOP) and Standards of Professional Performance (SOPP) for Registered Dietitian Nutritionists (RDNs) in Diabetes Care. The SOP and SOPP for RDNs in Diabetes Care provide indicators that describe three levels of practice: competent, proficient, and expert. The SOP utilizes the Nutrition Care Process and clinical workflow elements for care and management of those with diabetes and prediabetes. The SOPP describes six domains that focus on professionalism: Quality in Practice, Competence and Accountability, Provision of Services, Application of Research, Communication and Application of Knowledge, and Utilization and Management of Resources. Specific indicators outlined in the SOP and SOPP depict how these standards apply to practice. The SOP and SOPP are complementary resources for RDNs caring for individuals with diabetes or specializing in diabetes care or practicing in other diabetes-related areas, including research. The SOP and SOPP are intended to be used for RDN self-evaluation for ensuring competent practice and for determining potential education and training needs for advancement to a higher practice level in a variety of settings. Copyright © 2018 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  8. Refocusing acute psychiatry, performance management, standards and accountability, a new context for mental health nursing.

    LENUS (Irish Health Repository)

    Harnett, P J

    2009-06-01

    The term \\'performance management\\' has an aversive \\'managerial\\' aspect, is unappealing to many public sector staff and has an \\'image problem\\'. Perhaps as a consequence, it has failed to make a significant impact on Irish public sector workers, notably mental health nurses. In this paper, performance management is introduced and examined within an Irish healthcare context and with reference to its use in other countries. Some of the challenges faced by Irish mental health nurses and the potential benefits of working within a performance managed workplace are discussed. The paper concludes that performance management is likely to increasingly affect nurses, either as active agents or as passive recipients of a change that is thrust on them. The authors anticipate that the performance management \\'image problem\\' will give way to recognition that this is a fundamental change which has the potential to enable health services to change. This change will bring high standards of transparency, worker involvement in decision making, an explicit value base for health services and individual teams. It provides the potential for clear practice standards and high standards of transparency as well as worker welfare in all aspects, including supporting employment and career progression.

  9. New Buildings Energy Performance Improvement through Incorporation of New Proven Technologies into Standard Designs. Standard Design for TEMF

    National Research Council Canada - National Science Library

    Zhivov, Alexander M

    2004-01-01

    ISSUES: Current Army Standard Designs don't specify potential energy saving and sustainable design opportunities, available energy saving technologies, and technologies resulting in better indoor air quality...

  10. Predicting failing performance on a standardized patient clinical performance examination: the importance of communication and professionalism skills deficits.

    Science.gov (United States)

    Chang, Anna; Boscardin, Christy; Chou, Calvin L; Loeser, Helen; Hauer, Karen E

    2009-10-01

    The purpose is to determine which assessment measures identify medical students at risk of failing a clinical performance examination (CPX). Retrospective case-control, multiyear design, contingency table analysis, n = 149. We identified two predictors of CPX failure in patient-physician interaction skills: low clerkship ratings (odds ratio 1.79, P = .008) and student progress review for communication or professionalism concerns (odds ratio 2.64, P = .002). No assessments predicted CPX failure in clinical skills. Performance concerns in communication and professionalism identify students at risk of failing the patient-physician interaction portion of a CPX. This correlation suggests that both faculty and standardized patients can detect noncognitive traits predictive of failing performance. Early identification of these students may allow for development of a structured supplemental curriculum with increased opportunities for practice and feedback. The lack of predictors in the clinical skills portion suggests limited faculty observation or feedback.

  11. Regulating web content: the nexus of legislation and performance standards in the United Kingdom and Norway.

    Science.gov (United States)

    Giannoumis, G Anthony

    2014-01-01

    Despite different historical traditions, previous research demonstrates a convergence between regulatory approaches in the United Kingdom and Norway. To understand this convergence, this article examines how different policy traditions influence the legal obligations of performance standards regulating web content for use by persons with disabilities. While convergence has led to similar policy approaches, I argue that national policy traditions have an impact on how governments establish legal obligations for standards compliance. The analysis reveals that national policy traditions influenced antidiscrimination legislation and the capacity and authority of regulatory agencies, which impacted the diverging legal obligations of standards in the United Kingdom and Norway. The analysis further suggests that policy actors mediate the reciprocal influence between national policy traditions and regulatory convergence mechanisms. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Performance improvement of standard turbo-compressor; Han`yo turbo asshukuki no seino kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Hokari, T.; Hasegawa, K.; Ozaki, S.; Majima, K. [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan)

    1999-05-01

    Abradable materials are soft and cause no contact damage to the impeller of the turbo-compressor. Using such materials for the inlet casing facing to the impeller allows very small clearances between the impeller and inlet casing, thus improving the compressor efficiency by 10% over conventional types. Changing the area of abradable material applied to the inlet casing identified the optimum area in which decrease of the compressor surge margin is minimized and efficiency is improved by 10%. As a result, turbo-compressors have the best performance when the abradable materials are applied from the impeller outlet to two-thirds of the forward location of the inlet casing. (author)

  13. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-01

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either of those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.

  14. Standard Test Method for Electrical Performance of Concentrator Terrestrial Photovoltaic Modules and Systems Under Natural Sunlight

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of the electrical performance of photovoltaic concentrator modules and systems under natural sunlight using a normal incidence pyrheliometer. 1.2 The test method is limited to module assemblies and systems where the geometric concentration ratio specified by the manufacturer is greater than 5. 1.3 This test method applies to concentrators that use passive cooling where the cell temperature is related to the air temperature. 1.4 Measurements under a variety of conditions are allowed; results are reported under a select set of concentrator reporting conditions to facilitate comparison of results. 1.5 This test method applies only to concentrator terrestrial modules and systems. 1.6 This test method assumes that the module or system electrical performance characteristics do not change during the period of test. 1.7 The performance rating determined by this test method applies only at the period of the test, and implies no past or future performance level. 1.8...

  15. Does Lean Improve Labor Standards? Management and Social Performance in the Nike Supply Chain

    OpenAIRE

    Distelhorst, Greg; Hainmueller, Jens; Locke, Richard M.

    2016-01-01

    This study tests the hypothesis that lean manufacturing improves the social performance of manufacturers in emerging markets. We analyze an intervention by Nike Inc. to promote the adoption of lean manufacturing in its apparel supply chain across eleven developing countries. Using difference-in-differences estimates from a panel of over three hundred factories, we find that lean adoption was associated with a 15 percentage point reduction in noncompliance with labor standards t...

  16. Estimate of Technical Potential for Minimum Efficiency Performance Standards in 13 Major World Economies

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Desroches, Louis-Benoit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ke, Jing [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McNeil, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-07-01

    As part of the ongoing effort to estimate the foreseeable impacts of aggressive minimum efficiency performance standards (MEPS) programs in the world’s major economies, Lawrence Berkeley National Laboratory (LBNL) has developed a scenario to analyze the technical potential of MEPS in 13 major economies around the world1 . The “best available technology” (BAT) scenario seeks to determine the maximum potential savings that would result from diffusion of the most efficient available technologies in these major economies.

  17. Seismic Performance Comparison of a High-Content SDA Frame and Standard RC Frame

    OpenAIRE

    van de Lindt, John W.; Rechan, R. Karthik

    2011-01-01

    This study presents the method and results of an experiment to study the seismic behavior of a concrete portal frame with fifty percent of its cement content replaced with a spray dryer ash (SDA). Based on multiple-shake-table tests, the high content SDA frame was found to perform as well as the standard concrete frame for two earthquakes exceeding design-level intensity earthquakes. Hence, from a purely seismic/structural standpoint, it may be possible to replace approximately fifty percen...

  18. Performance-based standards (PBS) vehicles for transport in the agricultural sector

    CSIR Research Space (South Africa)

    Nordengen, Paul A

    2008-07-01

    Full Text Available manufacturers start designing vehicles on an ad hoc basis. It should be borne in mind that PBS vehicle designs include certain safety features, and must be loaded in the correct manner. The RTMS approach offers the most suitable way of ensuring.... The objectives of the Performance-Based Standards (PBS) philosophy are to utilise technology to reduce road damage, improve safety, increase payloads and reduce costs. To overcome the limitations of prescriptive legislation, is has been proposed that PBS...

  19. 40 CFR 63.7334 - How do I demonstrate continuous compliance with the work practice standards that apply to me?

    Science.gov (United States)

    2010-07-01

    ... for each oven and records indicating the legitimate operational reason for any change in the pushing... least 3 hours of observations (thirty 6-minute averages) to demonstrate initial compliance does not apply. (5) If fewer than six but at least four 15-second observations can be made, use the average of...

  20. When Military Fitness Standards No Longer Apply: The High Prevalence of Metabolic Syndrome in Recent Air Force Retirees

    Science.gov (United States)

    2017-08-27

    81.9% ), enlisted (71.1 % ) and had a mean age of 48.2 years. When applying the American Heart Association (AHA) MetS diagnostic criteria to this...central obesity , 39.8%; elevated fasting glucose, 32.4%; high blood pressure, 56.8%; low HDL-cholesterol, 33.3%; and elevated triglycerides, 42.7

  1. Comparing the performance of a new disposable pneumatic tocodynamometer with a standard tocodynamometer.

    Science.gov (United States)

    Eswaran, Hari; Wilson, James D; Murphy, Pam; Siegel, Eric R; Lowery, Curtis L

    2016-03-01

    The goal was to test a newly developed pneumatic tocodynamometer (pTOCO) that is disposable and lightweight, and evaluate its equivalence to the standard strain gauge-based tocodynamometer (TOCO). The equivalence between the devices was determined by both mechanical testing and recording of contractile events on women. The data were recorded simultaneously from a pTOCO prototype and standard TOCO that were in place on women who were undergoing routine contraction monitoring in the Labor and Delivery unit at the University of Arkansas for Medical Sciences. In this prospective equivalence study, the output from 31 recordings on 28 pregnant women that had 171 measureable contractions simultaneously in both types of TOCO were analyzed. The traces were scored for contraction start, peak and end times, and the duration of the event was computed from these times. The response curve to loaded weights and applied pressure were similar for both devices, indicating their mechanical equivalence. The paired differences in times and duration between devices were subjected to mixed-models analysis to test the pTOCO for equivalence with standard TOCOs using the two-one-sided tests procedure. The event times and duration analyzed simultaneously from both TOCO types were all found to be significantly equivalent to within ±10 s (all p-values ≤0.0001). pTOCO is equivalent to the standard TOCO in the detection of the timing and duration of uterine contractions. pTOCO would provide a lightweight, disposable alternative to commercially available standard TOCOs. © 2015 Nordic Federation of Societies of Obstetrics and Gynecology.

  2. Performance of three pencil-type ionization chambers (10 cm) in computed tomography standard beams

    International Nuclear Information System (INIS)

    Castro, Maysa C. de; Xavier, Marcos; Caldas, Linda V.E.

    2015-01-01

    The use of computed tomography (CT) has increased over the years, thus generating a concern about the doses received by patients undergoing this procedure. Therefore, it is necessary to perform routinely beam dosimetry with the use of a pencil-type ionization chamber. This detector is the most utilized in the procedures of quality control tests on this kind of equipment. The objective of this work was to perform some characterization tests in standard CT beams, as the saturation curve, polarity effect, ion collection efficiency and linearity of response, using three ionization chambers, one commercial and two developed at the IPEN. (author)

  3. Next Generation Space Interconnect Standard (NGSIS): a modular open standards approach for high performance interconnects for space

    Science.gov (United States)

    Collier, Charles Patrick

    2017-04-01

    The Next Generation Space Interconnect Standard (NGSIS) effort is a Government-Industry collaboration effort to define a set of standards for interconnects between space system components with the goal of cost effectively removing bandwidth as a constraint for future space systems. The NGSIS team has selected the ANSI/VITA 65 OpenVPXTM standard family for the physical baseline. The RapidIO protocol has been selected as the basis for the digital data transport. The NGSIS standards are developed to provide sufficient flexibility to enable users to implement a variety of system configurations, while meeting goals for interoperability and robustness for space. The NGSIS approach and effort represents a radical departure from past approaches to achieve a Modular Open System Architecture (MOSA) for space systems and serves as an exemplar for the civil, commercial, and military Space communities as well as a broader high reliability terrestrial market.

  4. The Bland-Altman analysis: Does it have a role in assessing radiation dosimeter performance relative to an established standard?

    International Nuclear Information System (INIS)

    Hill, R.F.; Tofts, P.S.; Baldock, C.

    2010-01-01

    Bland-Altman analysis is used to compare two different methods of measurement and to determine whether a new method of measurement may replace an existing accepted 'gold standard' method. In this work, Bland-Altman analysis has been applied to radiation dosimetry to compare the PTW Markus and Roos parallel plate ionisation chambers and a PTW PinPoint chamber against a Farmer type ionisation chamber which is accepted as the gold standard for radiation dosimetry in the clinic. Depth doses for low energy x-rays beams with energies of 50, 75 and 100 kVp were measured using each of the ionisation chambers. Depth doses were also calculated by interpolation of the data in the British Journal of Radiology (BJR) Report 25. From the Bland-Altman analysis, the mean dose difference between the two parallel plate chambers and the Farmer chambers was 1% over the range of depths measured. The PinPoint chamber gave significant dose differences compared to the Farmer chamber. There were also differences of up to 12% between the BJR Report 25 depth doses and the measured data. For the Bland-Altman plots, the lines representing the limits of agreement were selected to be a particular percentage agreement e.g. 1 or 2%, instead of being based on the standard deviation (σ) of the differences. The Bland-Altman statistical analysis is a powerful tool for making comparisons of ionisation chambers with an ionisation chamber that has been accepted as a 'gold standard'. Therefore we conclude that Bland-Altman analysis does have a role in assessing radiation dosimeter performance relative to an established standard.

  5. Benefit using reasonable regulations in USA, how to skill up on professional engineers, apply international code, standard, and regulation

    International Nuclear Information System (INIS)

    Turner, S.L.; Morokuzu, Muneo; Amano, Osamu

    2005-01-01

    The reasonable regulations in USA consist of a graduated approach and a risk informed approach (RIA). RIA rationalizes the regulations on the basis of data of operations etc. PSA (Probabilistic Safety Assessment), a general method of RIA, is explained in detail. The benefits of nuclear power plant using RIA are increase of the rate of operation, visualization of risk, application of design standard and design, cost down of nuclear fuel cycle, waste, production and operation, and safety. RIA is supported by the field data, code, standard, regulation and professional engineers. The effects of introduction of RIA are explained. In order to introduce RIA in Japan, all the parties concerned such as the regulation authorities, the electric power industries, makers, universities, have to understand it and work together. A part of scientific society is stated. (S.Y.)

  6. Implementation experiences of ISO/IEEE11073 standard applied to new use cases for e-health environments.

    Science.gov (United States)

    Martinez, I; Escayola, J; Martinez-Espronceda, M; Serrano, L; Trigo, J D; Led, S; Garcia, J

    2009-01-01

    Recent advances in biomedical engineering and continuous technological innovations in last decade are promoting new challenges, especially in e-Health environments. In this context, the medical devices interoperability is one of the interest fields wherein these improvements require a standard-based design in order to achieve homogeneous solutions. Furthermore, the spreading of wearable devices, oriented to the paradigm of patient environment and supported by wireless technologies as Bluetooth or ZigBee, is bringing new medical use cases based on Ambient Assisted Living, home monitoring of elderly, heart failure, chronic, under palliative care or patients who have undergone surgery, urgencies and emergencies, or even fitness auto-control and health follow-up. In this paper, several implementation experiences based on ISO/IEEE11073 standard are detailed. These evolved e-Health services can improve the quality of the patient's care, increase the user's interaction, and assure these e-Health applications to be fully compatible with global telemedicine systems.

  7. Developing and applying mobility performance measures for freight transportation in urban areas.

    Science.gov (United States)

    2010-12-01

    This report summarizes the activities performed in a one-year study with the objective to develop an : understanding of the interrelationships of urban goods movement and congestion and identify performance : measures that will help evaluate the impa...

  8. The accuracy of k1-standardized INAA applied to a gold-lined well-type detector

    International Nuclear Information System (INIS)

    Blaauw, M.

    2000-01-01

    The k 1 -method for standardization in INAA specifically tackles the problem of the interpretation of gamma-ray spectra as obtained with highly efficient detectors, as opposed to the k 0 -method. Results obtained from three NIST reference materials, measured after neutron activation with a gold-lined well-type detector, are presented. It is concluded that the accuracy of the method is better than 1%. (author)

  9. Performance and Complexity Co-evaluation of the Advanced Video Coding Standard for Cost-Effective Multimedia Communications

    Directory of Open Access Journals (Sweden)

    Saponara Sergio

    2004-01-01

    Full Text Available The advanced video codec (AVC standard, recently defined by a joint video team (JVT of ITU-T and ISO/IEC, is introduced in this paper together with its performance and complexity co-evaluation. While the basic framework is similar to the motion-compensated hybrid scheme of previous video coding standards, additional tools improve the compression efficiency at the expense of an increased implementation cost. As a first step to bridge the gap between the algorithmic design of a complex multimedia system and its cost-effective realization, a high-level co-evaluation approach is proposed and applied to a real-life AVC design. An exhaustive analysis of the codec compression efficiency versus complexity (memory and computational costs project space is carried out at the early algorithmic design phase. If all new coding features are used, the improved AVC compression efficiency (up to 50% compared to current video coding technology comes with a complexity increase of a factor 2 for the decoder and larger than one order of magnitude for the encoder. This represents a challenge for resource-constrained multimedia systems such as wireless devices or high-volume consumer electronics. The analysis also highlights important properties of the AVC framework allowing for complexity reduction at the high system level: when combining the new coding features, the implementation complexity accumulates, while the global compression efficiency saturates. Thus, a proper use of the AVC tools maintains the same performance as the most complex configuration while considerably reducing complexity. The reported results provide inputs to assist the profile definition in the standard, highlight the AVC bottlenecks, and select optimal trade-offs between algorithmic performance and complexity.

  10. ACCESS, Absolute Color Calibration Experiment for Standard Stars: Integration, Test, and Ground Performance

    Science.gov (United States)

    Kaiser, Mary Elizabeth; Morris, Matthew; Aldoroty, Lauren; Kurucz, Robert; McCandliss, Stephan; Rauscher, Bernard; Kimble, Randy; Kruk, Jeffrey; Wright, Edward L.; Feldman, Paul; Riess, Adam; Gardner, Jonathon; Bohlin, Ralph; Deustua, Susana; Dixon, Van; Sahnow, David J.; Perlmutter, Saul

    2018-01-01

    Establishing improved spectrophotometric standards is important for a broad range of missions and is relevant to many astrophysical problems. Systematic errors associated with astrophysical data used to probe fundamental astrophysical questions, such as SNeIa observations used to constrain dark energy theories, now exceed the statistical errors associated with merged databases of these measurements. ACCESS, “Absolute Color Calibration Experiment for Standard Stars”, is a series of rocket-borne sub-orbital missions and ground-based experiments designed to enable improvements in the precision of the astrophysical flux scale through the transfer of absolute laboratory detector standards from the National Institute of Standards and Technology (NIST) to a network of stellar standards with a calibration accuracy of 1% and a spectral resolving power of 500 across the 0.35‑1.7μm bandpass. To achieve this goal ACCESS (1) observes HST/ Calspec stars (2) above the atmosphere to eliminate telluric spectral contaminants (e.g. OH) (3) using a single optical path and (HgCdTe) detector (4) that is calibrated to NIST laboratory standards and (5) monitored on the ground and in-flight using a on-board calibration monitor. The observations are (6) cross-checked and extended through the generation of stellar atmosphere models for the targets. The ACCESS telescope and spectrograph have been designed, fabricated, and integrated. Subsystems have been tested. Performance results for subsystems, operations testing, and the integrated spectrograph will be presented. NASA sounding rocket grant NNX17AC83G supports this work.

  11. Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the electrical performance of photovoltaic modules and arrays under natural or simulated sunlight using a calibrated reference cell. 1.1.1 These test methods allow a reference module to be used instead of a reference cell provided the reference module has been calibrated using these test methods against a calibrated reference cell. 1.2 Measurements under a variety of conditions are allowed; results are reported under a select set of reporting conditions (RC) to facilitate comparison of results. 1.3 These test methods apply only to nonconcentrator terrestrial modules and arrays. 1.4 The performance parameters determined by these test methods apply only at the time of the test, and imply no past or future performance level. 1.5 These test methods apply to photovoltaic modules and arrays that do not contain series-connected photovoltaic multijunction devices; such module and arrays should be tested according to Test Methods E 2236. 1.6 The values stated in SI units are to be re...

  12. BRAZILIAN AND INTERNATIONAL ACCOUNTING STANDARDS APPLIED TO THE PUBLIC SECTOR AND THE CHALLENGE OF CONVERGENCE: A COMPARATIVE ANALYSIS - IPSAS AND NBCTSP

    Directory of Open Access Journals (Sweden)

    José Francisco Ribeiro Filho (in memoriam

    2012-11-01

    Full Text Available The aim in this study is to analyze the current stage of conceptual convergence between Brazilian accounting standards applied to the public sector (NBCTSP and the International Public Sector Accounting Standard (IPSAS. The complexity and range of transactions between public or private sector entities, as a result of market internationalization, demand continuous and dynamic assessment of the events that promote quantitative or qualitative equity changes. For this evaluation process, observing accounting principles and standards is important to guarantee, among other information characteristics, understandability and comparability, thus reducing costs for investors and users in general, in view of the barriers raised by diverse languages, cultures, tax and economic policies. For convergence analysis, the standards’ contents were subject to a comparative study, based on a descriptive analysis, with a view to verifying the existing adherence between Brazilian and international standards applied to the public sector. The results found highlight that different aspects still have to be discussed with a view to an actual convergence with the international standards; the current convergence is partial. The high-quality conceptual exposure of the NBCPSPs is observed though, while the contents of the IPSAS are more focused on operating procedures

  13. Residual recovery and yield performance of nitrogen fertilizer applied at sugarcane planting

    Directory of Open Access Journals (Sweden)

    Henrique Coutinho Junqueira Franco

    2015-12-01

    Full Text Available ABSTRACTThe low effectiveness of nitrogen fertilizer (N is a substantial concern that threatens global sugarcane production. The aim of the research reported in this paper was to assess the residual effect of N-fertilizer applied at sugarcane planting over four crop seasons in relation to sugarcane crop yield. Toward this end three field experiments were established in the state of São Paulo, Brazil, during February of 2005 and July of 2009, in a randomized block design with four treatments: 0, 40, 80 and 120 kg ha−1 of N applied as urea during sugarcane planting. Within each plot, a microplot was established to which 15N-labeled urea was applied. The application of N at planting increased plant cane yield in two of the three sites and sucrose content at the other, whereas the only residual effect was higher sucrose content in one of the following ratoons. The combined effect was an increase in sugar yield for three of the 11 crop seasons evaluated. Over the crop cycle of a plant cane and three ratoon crops, only 35 % of the applied N was recovered, split 75, 13, 7 and 5 % in the plant cane, first, second and third ratoons, respectively. These findings document the low efficiency of N recovery by sugarcane, which increases the risk that excessive N fertilization will reduce profitability and have an adverse effect on the environment.

  14. Towards Sustainable Performance Measurement Frameworks for Applied Research in Canadian Community Colleges and Institutes

    Science.gov (United States)

    Williams, Keith

    2014-01-01

    Applied Research (AR) in Canadian community colleges is driven by a mandate, via the collective voice of Colleges and Institutes Canada--a national voluntary membership association of publicly supported colleges and related institutions--to address issues of interest to industry, government, and/or community. AR is supported through significant…

  15. Standard Guidelines of Care: Performing Procedures in Patients on or Recently Administered with Isotretinoin.

    Science.gov (United States)

    Mysore, Venkataram; Mahadevappa, Omprakash H; Barua, Shyamanta; Majid, Imran; Viswanath, Vishalakshi; Bhat, Ramesh M; Talwar, Suresh; Thurakkal, Salim; Aurangabadkar, Sanjeev J; Chatterjee, Manas; Ganjoo, Anil

    2017-01-01

    Currently, the standard protocol regarding the performance of procedures on patients receiving or having recently received isotretinoin (13- cis -retinoic acid) states that the procedures should not be performed. The recommendations in standard books and drug insert require discontinuation of isotretinoin for 6 months before performing cosmetic procedures, including waxing, dermabrasion, chemical peels, laser procedures, or incisional and excisional cold-steel surgery. These recommendations have been followed for over two decades despite little evidence for the stated increased risk of scarring. The Association of Cutaneous Surgeons (I) constituted a task force to review the evidence and to recommend consensus guidelines regarding the safety of skin procedures, including resurfacing, energy-device treatments, and dermatosurgical procedures in patients with concurrent or recent isotretinoin administration. Data were extracted from the literature through a PubMed search using the keywords "isotretinoin," "safety," "scarring," "keloids," "hypertrophic scarring," and "pigmentation." The evidence was then labeled and circulated to all members of task force for review. The task force is of the opinion that there is insufficient evidence to support the current protocol of avoiding and delaying treatments in the patient group under consideration and recommends that the current practice should be discontinued. The task force concludes that performing procedures such as laser hair removal, fractional lasers for aging and acne scarring, lasers for pigmented skin lesions, fractional radio-frequency microneedling, superficial and medium-depth peels, microdermabrasion, dermaroller, biopsies, radio-frequency ablation, and superficial excisions is safe in patients with concurrent or recent isotretinoin administration.

  16. High performance liquid chromatography-charged aerosol detection applying an inverse gradient for quantification of rhamnolipid biosurfactants.

    Science.gov (United States)

    Behrens, Beate; Baune, Matthias; Jungkeit, Janek; Tiso, Till; Blank, Lars M; Hayen, Heiko

    2016-07-15

    A method using high performance liquid chromatography coupled to charged-aerosol detection (HPLC-CAD) was developed for the quantification of rhamnolipid biosurfactants. Qualitative sample composition was determined by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The relative quantification of different derivatives of rhamnolipids including di-rhamnolipids, mono-rhamnolipids, and their precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) differed for two compared LC-MS instruments and revealed instrument dependent responses. Our here reported HPLC-CAD method provides uniform response. An inverse gradient was applied for the absolute quantification of rhamnolipid congeners to account for the detector's dependency on the solvent composition. The CAD produces a uniform response not only for the analytes but also for structurally different (nonvolatile) compounds. It was demonstrated that n-dodecyl-β-d-maltoside or deoxycholic acid can be used as alternative standards. The method of HPLC-ultra violet (UV) detection after a derivatization of rhamnolipids and HAAs to their corresponding phenacyl esters confirmed the obtained results but required additional, laborious sample preparation steps. Sensitivity determined as limit of detection and limit of quantification for four mono-rhamnolipids was in the range of 0.3-1.0 and 1.2-2.0μg/mL, respectively, for HPLC-CAD and 0.4 and 1.5μg/mL, respectively, for HPLC-UV. Linearity for HPLC-CAD was at least 0.996 (R(2)) in the calibrated range of about 1-200μg/mL. Hence, the here presented HPLC-CAD method allows absolute quantification of rhamnolipids and derivatives. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Perceptual-cognitive expertise in sport: some considerations when applying the expert performance approach.

    Science.gov (United States)

    Williams, A Mark; Ericsson, K Anders

    2005-06-01

    The number of researchers studying perceptual-cognitive expertise in sport is increasing. The intention in this paper is to review the currently accepted framework for studying expert performance and to consider implications for undertaking research work in the area of perceptual-cognitive expertise in sport. The expert performance approach presents a descriptive and inductive approach for the systematic study of expert performance. The nature of expert performance is initially captured in the laboratory using representative tasks that identify reliably superior performance. Process-tracing measures are employed to determine the mechanisms that mediate expert performance on the task. Finally, the specific types of activities that lead to the acquisition and development of these mediating mechanisms are identified. General principles and mechanisms may be discovered and then validated by more traditional experimental designs. The relevance of this approach to the study of perceptual-cognitive expertise in sport is discussed and suggestions for future work highlighted.

  18. Standard compliance - NDE performance demonstration/inspection in the CANDU industry

    International Nuclear Information System (INIS)

    Choi, E.

    2011-01-01

    CANDU nuclear power plants are operated in 3 provinces in Canada for electric power generation. A table in the paper will show the built and operating plants in Ontario, Quebec, New Brunswick and overseas. The regulator for nuclear power in Canada is the Canadian Nuclear Safety Commission (CNSC). The CNSC holds the plant licensees accountable for compliance to CSA N285.4 for periodic inspections. The Standard basically specifies the 'what, when, where, how, how much and how frequently' NDE is to be done on pressure retaining systems and components in CANDU nuclear power plants. In inspection methods, the Standard specifies they must be non-destructive. The NDE methods were grouped into visual, dimensional, surface, volumetric and integrative. The Standard also specifies that the licensees are responsible for the performance demonstration (PD) of the adequacy of the procedures and the proficiency of the personnel. This paper describes the Standard's requirement in NDE qualification and presents a joint project participated by Canadian and overseas CANDU owners. The sub-project for NDE included providing evidence and technical justification on the adequacy of the procedures and the proficiency of the personnel. The paper describes the qualification methodology followed by the participants. This will be followed by how the participants produced Inspection Specification, tools and procedures, personnel training and qualification programs, test and qualification samples, independent peer reviews and Technical Justification. (author)

  19. Applying the roofline performance model to the intel xeon phi knights landing processor

    OpenAIRE

    Doerfler, D; Deslippe, J; Williams, S; Oliker, L; Cook, B; Kurth, T; Lobet, M; Malas, T; Vay, JL; Vincenti, H

    2016-01-01

    � Springer International Publishing AG 2016. The Roofline Performance Model is a visually intuitive method used to bound the sustained peak floating-point performance of any given arithmetic kernel on any given processor architecture. In the Roofline, performance is nominally measured in floating-point operations per second as a function of arithmetic intensity (operations per byte of data). In this study we determine the Roofline for the Intel Knights Landing (KNL) processor, determining t...

  20. Development of Design Concept and Applied Technology for RCP Performance Test Facility

    International Nuclear Information System (INIS)

    Park, Sang Jin; Lee, Jung Ho; Yoon, Seok Ho

    2010-02-01

    Performance test facility for RCP (reactor coolant pump) is essential to verify the performance and reliability of RCP before installation in the nuclear power plant. The development of RCP for new-type reactor and the performance verification of hydraulic revolving body also needs the RCP test facility. The design concept of test loop and the technology of flow rate measurement are investigated in this research

  1. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    Science.gov (United States)

    Biranjia-Hurdoyal, Susheela D; Seetulsingh-Goorah, Sharmila P

    2016-01-01

    The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit. Stool and blood samples were collected from 162 apparently healthy participants (control) and 60 Type 2 diabetes mellitus (T2DM) patients. The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; ppoor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value. The performances of the detection kits were affected by various factors which should be taken into consideration.

  2. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    Directory of Open Access Journals (Sweden)

    Susheela D Biranjia-Hurdoyal

    Full Text Available The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit.Stool and blood samples were collected from 162 apparently healthy participants (control and 60 Type 2 diabetes mellitus (T2DM patients.The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; p<0.05, accuracy = 86.4%, followed by EIA IgG (AUC = 0.75; p<0.05, accuracy = 75.2%. The Rapid Hexagon and EIA IgA kits had relatively poor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value.The performances of the detection kits were affected by various factors which should be taken into consideration.

  3. The Stock Performance of C. Everett Koop Award Winners Compared With the Standard & Poor's 500 Index.

    Science.gov (United States)

    Goetzel, Ron Z; Fabius, Raymond; Fabius, Dan; Roemer, Enid C; Thornton, Nicole; Kelly, Rebecca K; Pelletier, Kenneth R

    2016-01-01

    To explore the link between companies investing in the health and well-being programs of their employees and stock market performance. Stock performance of C. Everett Koop National Health Award winners (n = 26) was measured over time and compared with the average performance of companies comprising the Standard and Poor's (S&P) 500 Index. The Koop Award portfolio outperformed the S&P 500 Index. In the 14-year period tracked (2000-2014), Koop Award winners' stock values appreciated by 325% compared with the market average appreciation of 105%. This study supports prior and ongoing research demonstrating a higher market valuation--an affirmation of business success by Wall Street investors--of socially responsible companies that invest in the health and well-being of their workers when compared with other publicly traded firms.

  4. The Stock Performance of C. Everett Koop Award Winners Compared With the Standard & Poor's 500 Index

    Science.gov (United States)

    Goetzel, Ron Z.; Fabius, Raymond; Fabius, Dan; Roemer, Enid C.; Thornton, Nicole; Kelly, Rebecca K.; Pelletier, Kenneth R.

    2016-01-01

    Objective: To explore the link between companies investing in the health and well-being programs of their employees and stock market performance. Methods: Stock performance of C. Everett Koop National Health Award winners (n = 26) was measured over time and compared with the average performance of companies comprising the Standard and Poor's (S&P) 500 Index. Results: The Koop Award portfolio outperformed the S&P 500 Index. In the 14-year period tracked (2000–2014), Koop Award winners’ stock values appreciated by 325% compared with the market average appreciation of 105%. Conclusions: This study supports prior and ongoing research demonstrating a higher market valuation—an affirmation of business success by Wall Street investors—of socially responsible companies that invest in the health and well-being of their workers when compared with other publicly traded firms. PMID:26716843

  5. Performance of Differential-Phase-Shift Keying Protocol Applying 1310 nm Up-Conversion Single-Photon Detector

    International Nuclear Information System (INIS)

    Chen-Xu, Feng; Rong-Zhen, Jiao; Wen-Han, Zhang

    2008-01-01

    The performance of the differential-phase-shift keying (DPSK) protocol applying a 1310 nm up-conversion single-photon detector is analysed. The error rate and the communication rate as a function of distance for three quantum key distribution protocols, the Bennett–Brassard 1984, the Bennett–Brassard–Mermin 1992, and the DPSK, are presented. Then we compare the performance of these three protocols using the 1310nm up-conversion detector. We draw the conclusion that the DPSK protocol applying the detector has significant advantage over the other two protocols. Longer transmission distance and lower error rate can be achieved. (general)

  6. Performativity Double Standards and the Sexual Orientation Climate at a Southern Liberal Arts University.

    Science.gov (United States)

    Byron, Reginald A; Lowe, Maria R; Billingsley, Brianna; Tuttle, Nathan

    2017-01-01

    This study employs quantitative and qualitative methods to examine how heterosexual, bisexual, and gay students rate and describe a Southern, religiously affiliated university's sexual orientation climate. Using qualitative data, queer theory, and the concept tyranny of sexualized spaces, we explain why non-heterosexual students have more negative perceptions of the university climate than heterosexual male students, in both bivariate and multivariate analyses. Although heterosexual students see few problems with the campus sexual orientation climate, bisexual men and women describe being challenged on the authenticity of their orientation, and lesbian and, to a greater extent, gay male students report harassment and exclusion in a number of settings. These distinct processes are influenced by broader heteronormative standards. We also shed much-needed light on how gendered sexual performativity double standards within an important campus microclimate (fraternity parties) contribute to creating a tyrannical sexualized space and negatively affect overall campus climate perceptions.

  7. Performance evaluation of grid-enabled registration algorithms using bronze-standards

    CERN Document Server

    Glatard, T; Montagnat, J

    2006-01-01

    Evaluating registration algorithms is difficult due to the lack of gold standard in most clinical procedures. The bronze standard is a real-data based statistical method providing an alternative registration reference through a computationally intensive image database registration procedure. We propose in this paper an efficient implementation of this method through a grid-interfaced workflow enactor enabling the concurrent processing of hundreds of image registrations in a couple of hours only. The performances of two different grid infrastructures were compared. We computed the accuracy of 4 different rigid registration algorithms on longitudinal MRI images of brain tumors. Results showed an average subvoxel accuracy of 0.4 mm and 0.15 degrees in rotation.

  8. Post-LOCA long term cooling performance in Korean standard nuclear power plants

    International Nuclear Information System (INIS)

    Bang, Young Seok; Jung, Jae Won; Seul, Kwang Won; Kim, Hho Jung

    1999-01-01

    The post-LOCA long term cooling (LTC) performance of the Korean Standard Nuclear Power Plant (KSNPP) is analyzed for both small break LOCA and large break LOCA. The RELAP5/MOD3.2.2 code is used to calculate the LTC sequences based on the LTC plan of the KSNPP. A standard input model is developed such that LOCA and the followed LTC sequence can be calculated in a single run for both small break LOCA and large break LOCA. A spectrum of small break LOCA ranging from 0.02 to 0.5 ft 2 of break area and a double-ended guillotine break are analyzed. Through the code calculations, the thermal-hydraulic behavior and the boron behavior are evaluated and the effect of the important manual action including the safety injection tank isolation in LTC procedure is investigated

  9. Effects of setting new source performance standards for fluidized-bed combustion systems

    Energy Technology Data Exchange (ETDEWEB)

    1978-02-01

    This study was undertaken for the US Environmental Protection Agency to examine the potential consequences of revisions in New Source Performance Standards (NSPS) on fluidized-bed combustor-based steam electric generators of greater than 250,000,000 Btu. A study of the appropriateness and differential effects of alternate regulatory approaches to the standards-setting process was made. Problems dealing with an emerging technology such as fluidized-bed combustion were emphasized. Finally, an examination was made of the potential benefits of fluidized-bed combustion (FBC) systems relative to conventional coal-fired systems equipped with scrubbers. Information is included on the relative advantages and disadvantages of utility-sized fluidized-bed combustors, the technical consequences of NSPS alternatives, policy implications concerning NSPS for steam-electric generators, and cost models for atmospheric and pressurized FBC systems. (LCL)

  10. A Three-Dimensional Foil Bearing Performance Map Applied to Oil-Free Turbomachinery

    Science.gov (United States)

    2009-04-01

    stress brought on by excessive viscous power loss; therefore a map that graphically relates component and system-level parameters (bearing size, applied...Introduction Foil bearings are self-acting, hydrodynamic gas bearings that use air as their working fluid . Their use in rotating systems eliminates the...weight, maintenance requirements, speed, and temperature limitations associated with conventional oil-lubricated rotor supports (i.e., bearings, dampers

  11. Rutting Performance of Cold-Applied Asphalt Repair Materials for Airfield Pavements

    Science.gov (United States)

    2017-06-23

    this study. Cold mix asphalt materials, further denoted cold mixes , were selected to reasonably represent available products on the market and were...pavement repair, primarily because of the small quantities involved and/or the unavailability of hot- mixed asphalt. These cold-applied mixtures have...poorer rutting resistance than hot mix asphalt because additives, often solvent, are required to provide adequate workability for them to be placed

  12. Performance comparison of two efficient genomic selection methods (gsbay & MixP) applied in aquacultural organisms

    Science.gov (United States)

    Su, Hailin; Li, Hengde; Wang, Shi; Wang, Yangfan; Bao, Zhenmin

    2017-02-01

    Genomic selection is more and more popular in animal and plant breeding industries all around the world, as it can be applied early in life without impacting selection candidates. The objective of this study was to bring the advantages of genomic selection to scallop breeding. Two different genomic selection tools MixP and gsbay were applied on genomic evaluation of simulated data and Zhikong scallop ( Chlamys farreri) field data. The data were compared with genomic best linear unbiased prediction (GBLUP) method which has been applied widely. Our results showed that both MixP and gsbay could accurately estimate single-nucleotide polymorphism (SNP) marker effects, and thereby could be applied for the analysis of genomic estimated breeding values (GEBV). In simulated data from different scenarios, the accuracy of GEBV acquired was ranged from 0.20 to 0.78 by MixP; it was ranged from 0.21 to 0.67 by gsbay; and it was ranged from 0.21 to 0.61 by GBLUP. Estimations made by MixP and gsbay were expected to be more reliable than those estimated by GBLUP. Predictions made by gsbay were more robust, while with MixP the computation is much faster, especially in dealing with large-scale data. These results suggested that both algorithms implemented by MixP and gsbay are feasible to carry out genomic selection in scallop breeding, and more genotype data will be necessary to produce genomic estimated breeding values with a higher accuracy for the industry.

  13. Appraising and applying evidence about a diagnostic test during a performance-based assessment

    Directory of Open Access Journals (Sweden)

    Franklin Ellen

    2004-10-01

    Full Text Available Abstract Background The practice of Evidence-based Medicine requires that clinicians assess the validity of published research and then apply the results to patient care. We wanted to assess whether our soon-to-graduate medical students could appraise and apply research about a diagnostic test within a clinical context and to compare our students with peers trained at other institutions. Methods 4th year medical students who previously had demonstrated competency at probability revision and just starting first-year Internal Medicine residents were used for this research. Following an encounter with a simulated patient, subjects critically appraised a paper about an applicable diagnostic test and revised the patient's pretest probability given the test result. Results The medical students and residents demonstrated similar skills at critical appraisal, correctly answering 4.7 and 4.9, respectively, of 6 questions (p = 0.67. Only one out of 28 (3% medical students and none of the 15 residents were able to correctly complete the probability revision task (p = 1.00. Conclusions This study found that most students completing medical school are able to appraise an article about a diagnostic test but few are able to apply the information from the article to a patient. These findings raise questions about the clinical usefulness of the EBM skills possessed by graduating medical students within the area of diagnostic testing.

  14. Applying Service Performance Guarantees to Reduce Risk Perception in the Purchase and Consumption of Higher Education

    Directory of Open Access Journals (Sweden)

    Nooraini Mohamad Sheriff

    2006-12-01

    Full Text Available The intangible nature of education is one contributor to consumers’ perception of risk prior to their purchase and consumption. This risk includes: functional risk, financial risk, temporal risk, physical risk, psychological risk and social risk. The presence of these risks often makes consumer evaluation prior to purchase and consumption difficult. Invoking a service guarantee is a platform available to enable higher educational institutions to minimize such risk perception so as to induce purchase. Specifically, service guarantee for higher education entails the application of teaching performance guarantee. This form of guarantee focuses on two important customer groups of higher educational institutions namely, students and faculty members, and focuses only on a specific performance aspect such as instructor’s performance. Thus, if students are dissatisfied with an instructor’s performance they are entitled to receive their money back. The imposition of such a teaching performance guarantee would implicate instructor’s accountability for certain aspects of their performance. It also establishes a mechanism to solicit feedback to better understand why and how instructors fail. Consequently, service performance guarantee creates a high level of customer focus and signals instructors’ care towards students

  15. Virginia Standards of Learning (Grades 6 through 12) That Are Covered When Students Attend Live Performances of Shakespeare's Plays.

    Science.gov (United States)

    Brookshire, Cathy A.

    This paper outlines Standards of Learning for grades 6-12 students in Virginia that are covered when they attend live performances of William Shakespeare's plays. The paper details separate standards for each grade in English, subdivided into standards which fulfill requirements in Oral Language, Reading/Literature, Writing, and Research, along…

  16. JACoW Automatic PID performance monitoring applied to LHC cryogenics

    CERN Document Server

    Bradu, Benjamin; Marti, Ruben; Tilaro, Filippo

    2018-01-01

    At CERN, the LHC (Large Hadron Collider) cryogenic system employs about 5000 PID (Proportional Integral Derivative) regulation loops distributed over the 27 km of the accelerator. Tuning all these regulation loops is a complex task and the systematic monitoring of them should be done in an automated way to be sure that the overall plant performance is improved by identifying the poorest performing PID controllers. It is nearly impossible to check the performance of a regulation loop with a classical threshold technique as the controlled variables could evolve in large operation ranges and the amount of data cannot be manually checked daily. This paper presents the adaptation and the application of an existing regulation indicator performance algorithm on the LHC cryogenic system and the different results obtained in the past year of operation. This technique is generic for any PID feedback control loop, it does not use any process model and needs only a few tuning parameters. The publication also describes th...

  17. ANALYTIC NETWORK PROCESS AND BALANCED SCORECARD APPLIED TO THE PERFORMANCE EVALUATION OF PUBLIC HEALTH SYSTEMS

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Reis dos Santos

    2015-08-01

    Full Text Available The performance of public health systems is an issue of great concern. After all, to assure people's quality of life, public health systems need different kinds of resources. Balanced Scorecard provides a multi-dimensional evaluation framework. This paper presents the application of the Analytic Network Process and Balanced Scorecard in the performance evaluation of a public health system in a typical medium-sized Southeastern town in Brazil.

  18. Environmental assessment for the electric and hybrid vehicle demonstration project, performance standards and financial incentives

    Energy Technology Data Exchange (ETDEWEB)

    LaBelle, S. J.

    1978-10-01

    The assessment is concerned with the impacts of the demonstration of electric and hybrid vehicles acquired to fulfill certain requirements of the Electric and Hybrid Vehicle Research, Development, and Demonstration Act, PL 94-413 as amended. The financial incentives programs and vehicle performance standards associated with the demonstration are also covered. Not included is an assessment of the long term effects of EHV commercialization and of the research and development program being carried out simultaneously with the demonstration, also in response to PL 94-413. These federal actions will be included in a programmatic environmental assessment scheduled for completion in FY 79.

  19. Confronting Regulatory Cost and Quality Expectations. An Exploration of Technical Change in Minimum Efficiency Performance Standards

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Margaret [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stanford Univ., CA (United States); Spurlock, C. Anna [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Yang, Hung-Chia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-09-21

    The dual purpose of this project was to contribute to basic knowledge about the interaction between regulation and innovation and to inform the cost and benefit expectations related to technical change which are embedded in the rulemaking process of an important area of national regulation. The area of regulation focused on here is minimum efficiency performance standards (MEPS) for appliances and other energy-using products. Relevant both to U.S. climate policy and energy policy for buildings, MEPS remove certain product models from the market that do not meet specified efficiency thresholds.

  20. Internationally Standardized Reporting (Checklist) on the Sustainable Development Performance of Uranium Mining and Processing Sites

    International Nuclear Information System (INIS)

    Harris, Frank

    2014-01-01

    The Internationally Standardized Reporting Checklist on the Sustainable Development Performance of Uranium Mining and Processing Sites: • A mutual and beneficial work between a core group of uranium miners and nuclear utilities; • An approach based on an long term experience, international policies and sustainable development principles; • A process to optimize the reporting mechanism, tools and efforts; • 11 sections focused on the main sustainable development subject matters known at an operational and headquarter level. The WNA will make available the sustainable development checklist for member utilities and uranium suppliers. Utilities and suppliers are encouraged to use the checklist for sustainable development verification.

  1. Applying Machine Learning and High Performance Computing to Water Quality Assessment and Prediction

    OpenAIRE

    Ruijian Zhang; Deren Li

    2017-01-01

    Water quality assessment and prediction is a more and more important issue. Traditional ways either take lots of time or they can only do assessments. In this research, by applying machine learning algorithm to a long period time of water attributes’ data; we can generate a decision tree so that it can predict the future day’s water quality in an easy and efficient way. The idea is to combine the traditional ways and the computer algorithms together. Using machine learning algorithms, the ass...

  2. Employee perceptions of line management performance: applying the AMO theory to explain the effectiveness of line managers' HRM implementation

    NARCIS (Netherlands)

    Bos-Nehles, Anna Christina; van Riemsdijk, Maarten; Looise, Jan C.

    2013-01-01

    Line managers are today seen as increasingly important in effectively implementing HRM practices. Based on the Ability-Motivation-Opportunity (AMO) theory, we predict that line managers' performance in this regard will depend on their ability to apply HRM practices, and that their motivation and the

  3. The learning theories’ knowledge applied in the performance of distance tutor

    Directory of Open Access Journals (Sweden)

    Fernanda Abreu de Moraes Figueiredo

    2016-07-01

    Full Text Available Abstract: This study aimed to identify the most influential theory of learning related to the practice of mentoring from behaviorism, cognitivism, humanism, the sociocultural theory and connectivism, and apply the most appropriate theories to solve common problems in distance education. For this purpose, we used the literature method. It was noted that each of the theories end up being influential to the role of tutor. Therefore, the learning tends to be richer in the ratio and effective to apply different theories together. However, that support better substantiating tutor's role is humanism, the sociocultural theory and connectivism. It was noticed that the problems often experienced by students in distance education are due to failures tutor interaction and affection, implying to resolve them closer tutor with the student to have more responsibility in the exchange of information, meeting deadlines and clarity in the disclosure notes assessments. Knowledge are mainly from humanism and sociocultural theory that end up not only reasons for existence of the tutor as serving to improve the development of the quality of tutor-student interaction. Keywords: learning theories; distance learning (DL; tutor distance.

  4. Investigation of Performance Task Studies Applied by Turkish Teachers for the Purpose of Consolidation and Evaluation

    Directory of Open Access Journals (Sweden)

    Ali GÖÇER

    2014-04-01

    Full Text Available The aim of this study is to provide an overview of the applications of task performance as they are used to determine the status of the development in process and acquire the senior mental, linguistic, and social skills of students in secondary school Turkish lessons. In this study which adapted action research design in qualitative research approach, the data were obtained through interviews and document analysis method. The study was conducted on a study group consisting of 13 Turkish teachers. The data were obtained using the main form of the interview as a means of data collection. Additionally, were collected as examined document that products made by the task performance of students. The data were examined with content analysis method. According to the results of the data, almost all of the teachers in the study group have implemented performance tasks in accordance with the decisions of branch and the curriculum of the course.

  5. Evaluation of post-LOCA long term cooling performance in Korean standard nuclear power plants

    International Nuclear Information System (INIS)

    Bang, Young Seok; Jung, Jae Won; Seul, Kwang Won; Kim, Hho Jung

    2001-01-01

    The post-LOCA long term cooling (LTC) performance of the Korean Standard Nuclear Power Plant (KSNPP) is analyzed for both small break loss-of-coolant accidents (LOCA) and large break LOCA at cold leg. The RELAP5/MOD3.2.2 beta code is used to calculate the LTC sequences based on the LTC plan of the Korean Standard Nuclear Power Plants (KSNPP). A standard input model is developed such that LOCA and the followed LTC sequence can be calculated in a single run for both small break LOCA and large break LOCA. A spectrum of small break LOCA ranging from 0.02 to 0.5 ft 2 of break area and a double-ended guillotine break are analyzed. Through the code calculations, the thermal-hydraulic behavior and the boron behavior are evaluated and the effect of the important action including the safety injection tank (SIT) isolation and the simultaneous injection in LTC procedure is investigated. As a result, it is found that the sufficient margin is available in avoiding the boron precipitation in the core. It is also found that a further specific condition for the SIT isolation action need to be setup and it is recommended that the early initiation of the simultaneous injection be taken for larger break LTC sequences. (author)

  6. Applying mathematical models to predict resident physician performance and alertness on traditional and novel work schedules.

    Science.gov (United States)

    Klerman, Elizabeth B; Beckett, Scott A; Landrigan, Christopher P

    2016-09-13

    In 2011 the U.S. Accreditation Council for Graduate Medical Education began limiting first year resident physicians (interns) to shifts of ≤16 consecutive hours. Controversy persists regarding the effectiveness of this policy for reducing errors and accidents while promoting education and patient care. Using a mathematical model of the effects of circadian rhythms and length of time awake on objective performance and subjective alertness, we quantitatively compared predictions for traditional intern schedules to those that limit work to ≤ 16 consecutive hours. We simulated two traditional schedules and three novel schedules using the mathematical model. The traditional schedules had extended duration work shifts (≥24 h) with overnight work shifts every second shift (including every third night, Q3) or every third shift (including every fourth night, Q4) night; the novel schedules had two different cross-cover (XC) night team schedules (XC-V1 and XC-V2) and a Rapid Cycle Rotation (RCR) schedule. Predicted objective performance and subjective alertness for each work shift were computed for each individual's schedule within a team and then combined for the team as a whole. Our primary outcome was the amount of time within a work shift during which a team's model-predicted objective performance and subjective alertness were lower than that expected after 16 or 24 h of continuous wake in an otherwise rested individual. The model predicted fewer hours with poor performance and alertness, especially during night-time work hours, for all three novel schedules than for either the traditional Q3 or Q4 schedules. Three proposed schedules that eliminate extended shifts may improve performance and alertness compared with traditional Q3 or Q4 schedules. Predicted times of worse performance and alertness were at night, which is also a time when supervision of trainees is lower. Mathematical modeling provides a quantitative comparison approach with potential to aid

  7. A performance improvement program applied to the Perry Nuclear Power Plant instrumentation and control section

    International Nuclear Information System (INIS)

    Anderson, G.R.

    1987-01-01

    The management at Cleveland Electric Illuminating Company sought to avoid problems typically encountered in the start-up of new nuclear generating units. In response to early indications that such problems may have been developing at their Perry Nuclear Power Plant, several performance improvement initiatives were undertaken. One of these initiatives was a performance improvement evaluation (PIE) for the instrumentation and control (IandC) section at Perry. The IandC PIE, which used a method designed to be adaptable to other disciplines as well, had important results that are applicable to other nuclear power plants

  8. Site Characterization and Preliminary Performance Assessment Calculation Applied To JAEA-Horonobe URL Site of Japan

    International Nuclear Information System (INIS)

    Lim, Doo Hyun; Hatanaka, Koichiro; Ishii, Eiichi

    2010-01-01

    JAEA-Horonobe Underground Research Laboratory (URL) is designed for research and development on high-level radioactive waste (HLW) repository in sedimentary rock. For a potential HLW repository, understanding and implementing fracturing and faulting system, with data from the site characterization, into the performance assessment is essential because fracture and fault will be the major conductors or barriers for the groundwater flow and radionuclide release. The objectives are i) quantitative derivation of characteristics and correlation of fracturing/faulting system with geologic and geophysics data obtained from the site characterization, and ii) preliminary performance assessment calculation with characterized site information

  9. Site Characterization and Preliminary Performance Assessment Calculation Applied To JAEA-Horonobe URL Site of Japan

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Doo Hyun [NE Union Hill Road, Suite 200, WA 98052 (United States); Hatanaka, Koichiro; Ishii, Eiichi [Japan Atomic Energy Agency, Hokkaido (Japan)

    2010-10-15

    JAEA-Horonobe Underground Research Laboratory (URL) is designed for research and development on high-level radioactive waste (HLW) repository in sedimentary rock. For a potential HLW repository, understanding and implementing fracturing and faulting system, with data from the site characterization, into the performance assessment is essential because fracture and fault will be the major conductors or barriers for the groundwater flow and radionuclide release. The objectives are i) quantitative derivation of characteristics and correlation of fracturing/faulting system with geologic and geophysics data obtained from the site characterization, and ii) preliminary performance assessment calculation with characterized site information

  10. Performance of Ruecking's Word-compression Method When Applied to Machine Retrieval from a Library Catalog

    Directory of Open Access Journals (Sweden)

    Ben-Ami Lipetz

    1969-12-01

    Full Text Available F. H. Ruecking's word-compression algorithm for retrieval of bibliographic data from computer stores was tested for performance in matching user-supplied, unedited bibliographic data to the bibliographic data contained in a library catalog. The algorithm was tested by manual simulation, using data derived from 126 case studies of successful manual searches of the card catalog at Sterling Memorial Library, Yale University. The algorithm achieved 70% recall in comparison to conventional searching. Its accepta- bility as a substitute for conventional catalog searching methods is ques- tioned unless recall performance can be improved, either by use of the algorithm alone or in combination with other algorithms.

  11. Frontier: High Performance Database Access Using Standard Web Components in a Scalable Multi-Tier Architecture

    International Nuclear Information System (INIS)

    Kosyakov, S.; Kowalkowski, J.; Litvintsev, D.; Lueking, L.; Paterno, M.; White, S.P.; Autio, Lauri; Blumenfeld, B.; Maksimovic, P.; Mathis, M.

    2004-01-01

    A high performance system has been assembled using standard web components to deliver database information to a large number of broadly distributed clients. The CDF Experiment at Fermilab is establishing processing centers around the world imposing a high demand on their database repository. For delivering read-only data, such as calibrations, trigger information, and run conditions data, we have abstracted the interface that clients use to retrieve data objects. A middle tier is deployed that translates client requests into database specific queries and returns the data to the client as XML datagrams. The database connection management, request translation, and data encoding are accomplished in servlets running under Tomcat. Squid Proxy caching layers are deployed near the Tomcat servers, as well as close to the clients, to significantly reduce the load on the database and provide a scalable deployment model. Details the system's construction and use are presented, including its architecture, design, interfaces, administration, performance measurements, and deployment plan

  12. Standardizing the performance evaluation of short-term wind prediction models

    DEFF Research Database (Denmark)

    Madsen, Henrik; Pinson, Pierre; Kariniotakis, G.

    2005-01-01

    Short-term wind power prediction is a primary requirement for efficient large-scale integration of wind generation in power systems and electricity markets. The choice of an appropriate prediction model among the numerous available models is not trivial, and has to be based on an objective...... evaluation of model performance. This paper proposes a standardized protocol for the evaluation of short-term wind-poser preciction systems. A number of reference prediction models are also described, and their use for performance comparison is analysed. The use of the protocol is demonstrated using results...... from both on-shore and off-shore wind forms. The work was developed in the frame of the Anemos project (EU R&D project) where the protocol has been used to evaluate more than 10 prediction systems....

  13. A lack of standardization: the basis for the ethical issues surrounding quality and performance reports.

    Science.gov (United States)

    Suchy, Kirsten

    2010-01-01

    Consumers in the United States are taking advantage of the proliferation of publicly available, internet-based performance reports and quality appraisals of health plans, healthcare organizations, hospitals, and physicians to aid in their healthcare decision making. However, these appraisal practices have given rise to controversy and debate over certain distinctive ethical issues. This article advocates a standardized ethical framework to guide current and future development and implementation of performance reports. This framework, which would resolve a number of the major issues, includes the following ethical principles to guide the practice of public reporting on the Internet and facilitate enhanced quality improvement in the healthcare industry: legitimacy, data integrity and quality, transparency, informed understanding, equity, privacy and confidentiality, collaboration, accountability, and evaluation and continuous improvement.

  14. Applying standard epidemiological methods for investigating foodborne disease outbreak in resource-poor settings: lessons from Vietnam.

    Science.gov (United States)

    Vo, Thuan Huu; Nguyen, Dat Van; Le, Loan Thi Kim; Phan, Lan Trong; Nuorti, J Pekka; Tran Minh, Nguyen Nhu

    2014-07-01

    An outbreak of gastroenteritis occurred among workers of company X after eating lunch prepared by a catering service. Of 430 workers attending the meal, 56 were hospitalized with abdominal pain, diarrhea, vomiting, and nausea, according to the initial report. We conducted an investigation to identify the extent, vehicle, and source of the outbreak. In our case-control study, a case was a worker who attended the meal and who was hospitalized with acute gastroenteritis; controls were randomly selected from non-ill workers. Cases and controls were interviewed using a standard questionnaire. We used logistic regression to calculate adjusted odds ratios for the consumption of food items. Catering service facilities and food handlers working for the service were inspected. Food samples from the catering service were tested at reference laboratories. Of hospitalized cases, 54 fulfilled the case definition, but no stool specimens were collected for laboratory testing. Of four food items served during lunch, only "squash and pork soup" was significantly associated with gastroenteritis, with an adjusted odds ratio of 9.5 (95 % CI 3.2, 27.7). The caterer did not separate cooked from raw foods but used the same counter for both. Cooked foods were kept at room temperature for about 4 h before serving. Four of 14 food handlers were not trained on basic food safety principles and did not have health certificates. Although no microbiological confirmation was obtained, our epidemiological investigation suggested that squash and pork soup caused the outbreak. Hospitals should be instructed to obtain stool specimens from patients with gastroenteritis. Food catering services should be educated in basic food safety measures.

  15. Standardization of the energy performance of photovoltaic modules in real operating conditions

    Directory of Open Access Journals (Sweden)

    Viganó Davide

    2014-01-01

    Full Text Available The performance of a PV module at STC [1] is a useful indicator for comparing the peak performance of different module types, but on its own is not sufficient to accurately predict how much energy a module will deliver in the field when subjected to a wide range of real operating conditions [2]. An Energy Rating approach has to be preferred for that aim. It is currently under development the standard series IEC 61853 on Energy Rating, for which only part 1 [3] has been issued. It describes methods to characterize the module performance as a function of irradiance and temperature. The reproducibility of the power matrix measurements obtained by the three different methods specified in the standard, namely: under natural sunlight using a tracking system; under natural sunlight without tracker; and a large area pulsed solar simulator of Class AAA were evaluated and discussed [4,5]. The work here presented is focused on the second method listed above, which explores the real working conditions for a PV device and therefore it represents the situation where Energy Rating procedures are expected to give the largest deviations from the STC predictions. The system for continuous monitoring of module performances, already implemented at ESTI, has been recently replaced with a new system having a number of improvements described in the following. The two system results have been compared showing a discrete compatibility. The two power matrices are then merged together using a weighted average and compared to those acquired with the other two remaining “ideal” systems. An interesting tendency seems to come up from this comparison, making the power rating under real operating conditions an essential procedure for energy rating purposes.

  16. Standard Guidelines of Care: Performing Procedures in Patients on or Recently Administered with Isotretinoin

    Science.gov (United States)

    Mysore, Venkataram; Mahadevappa, Omprakash H.; Barua, Shyamanta; Majid, Imran; Viswanath, Vishalakshi; Bhat, Ramesh M.; Talwar, Suresh; Thurakkal, Salim; Aurangabadkar, Sanjeev J.; Chatterjee, Manas; Ganjoo, Anil

    2017-01-01

    Background: Currently, the standard protocol regarding the performance of procedures on patients receiving or having recently received isotretinoin (13-cis-retinoic acid) states that the procedures should not be performed. The recommendations in standard books and drug insert require discontinuation of isotretinoin for 6 months before performing cosmetic procedures, including waxing, dermabrasion, chemical peels, laser procedures, or incisional and excisional cold-steel surgery. These recommendations have been followed for over two decades despite little evidence for the stated increased risk of scarring. Objective: The Association of Cutaneous Surgeons (I) constituted a task force to review the evidence and to recommend consensus guidelines regarding the safety of skin procedures, including resurfacing, energy-device treatments, and dermatosurgical procedures in patients with concurrent or recent isotretinoin administration. Materials and Methods: Data were extracted from the literature through a PubMed search using the keywords “isotretinoin,” “safety,” “scarring,” “keloids,” “hypertrophic scarring,” and “pigmentation.” The evidence was then labeled and circulated to all members of task force for review. Results: The task force is of the opinion that there is insufficient evidence to support the current protocol of avoiding and delaying treatments in the patient group under consideration and recommends that the current practice should be discontinued. The task force concludes that performing procedures such as laser hair removal, fractional lasers for aging and acne scarring, lasers for pigmented skin lesions, fractional radio-frequency microneedling, superficial and medium-depth peels, microdermabrasion, dermaroller, biopsies, radio-frequency ablation, and superficial excisions is safe in patients with concurrent or recent isotretinoin administration. PMID:29491653

  17. Standard guidelines of care: Performing procedures in patients on or recently administered with isotretinoin

    Directory of Open Access Journals (Sweden)

    Venkataram Mysore

    2017-01-01

    Full Text Available Background: Currently, the standard protocol regarding the performance of procedures on patients receiving or having recently received isotretinoin (13-cis-retinoic acid states that the procedures should not be performed. The recommendations in standard books and drug insert require discontinuation of isotretinoin for 6 months before performing cosmetic procedures, including waxing, dermabrasion, chemical peels, laser procedures, or incisional and excisional cold-steel surgery. These recommendations have been followed for over two decades despite little evidence for the stated increased risk of scarring. Objective: The Association of Cutaneous Surgeons (I constituted a task force to review the evidence and to recommend consensus guidelines regarding the safety of skin procedures, including resurfacing, energy-device treatments, and dermatosurgical procedures in patients with concurrent or recent isotretinoin administration. Materials and Methods: Data were extracted from the literature through a PubMed search using the keywords “isotretinoin,” “safety,” “scarring,” “keloids,” “hypertrophic scarring,” and “pigmentation.” The evidence was then labeled and circulated to all members of task force for review. Results: The task force is of the opinion that there is insufficient evidence to support the current protocol of avoiding and delaying treatments in the patient group under consideration and recommends that the current practice should be discontinued.The task force concludes that performing procedures such as laser hair removal, fractional lasers for aging and acne scarring, lasers for pigmented skin lesions, fractional radio-frequency microneedling, superficial and medium-depth peels, microdermabrasion, dermaroller, biopsies, radio-frequency ablation, and superficial excisions is safe in patients with concurrent or recent isotretinoin administration.

  18. Photocatalysis applied to concrete products - part 2 : influencing factors and product performance

    NARCIS (Netherlands)

    Hunger, M.; Hüsken, G.; Brouwers, H.J.H.

    2008-01-01

    The second part of this three-part article series addresses the influence of physicochemical parameters on the degradation performance of concrete products containing photocatalytic active TiO2. The influence of process conditions like irradiance, relative humidity, pollutant concentration and flow

  19. Applied Chaos Level Test for Validation of Signal Conditions Underlying Optimal Performance of Voice Classification Methods

    Science.gov (United States)

    Liu, Boquan; Polce, Evan; Sprott, Julien C.; Jiang, Jack J.

    2018-01-01

    Purpose: The purpose of this study is to introduce a chaos level test to evaluate linear and nonlinear voice type classification method performances under varying signal chaos conditions without subjective impression. Study Design: Voice signals were constructed with differing degrees of noise to model signal chaos. Within each noise power, 100…

  20. Applying Learning Analytics for the Early Prediction of Students' Academic Performance in Blended Learning

    Science.gov (United States)

    Lu, Owen H. T.; Huang, Anna Y. Q.; Huang, Jeff C. H.; Lin, Albert J. Q.; Ogata, Hiroaki; Yang, Stephen J. H.

    2018-01-01

    Blended learning combines online digital resources with traditional classroom activities and enables students to attain higher learning performance through well-defined interactive strategies involving online and traditional learning activities. Learning analytics is a conceptual framework and is a part of our Precision education used to analyze…

  1. High-Performance Classrooms for Women? Applying a Relational Frame to Management/Organizational Behavior Courses.

    Science.gov (United States)

    Buttner, E. Holly

    2002-01-01

    Attributes of relational theory, based on women's development, include preventive connecting, mutual empowering, achieving, and team building. These attributes are compatible with the practices of high performance work organizations. Relational practices should be integrated into management and organizational behavior courses. (Contains 53…

  2. The development of national quality performance standards for disposable absorbent products for adult incontinence.

    Science.gov (United States)

    Muller, Nancy; McInnis, Elaine

    2013-09-01

    Disposable absorbent products are widely used in inpatient care settings and in the community to manage adult urinary and fecal incontinence, but few product standards exist to help guide their production or optimal use. Increasing costs and reduced revenues have caused a number of states to evaluate absorbent product use among persons who receive care at home with the assistance of the Medicaid Waiver Program, further increasing concerns about the lack of product performance standards. To address these issues, the National Association For Continence (NAFC) formed a council of experts and key stakeholders with the objective of establishing national, independent quality performance standards for disposable absorbent products provided by states to Waiver Program recipients. The Council consisted of representatives from five purposefully selected states, technical directors from six nonwoven product manufacturers, an officer of the nonwoven manufactures trade association, a delegate from an academic nursing program and professional societies, a family caregiver, and a patient representative. Following a consensus method and guidelines for use, nine specific recommendations were developed, posted for public comment, and further refined. Final recommendations for product performance assessment include: rewet rate (a measure of a product's ability to withstand multiple incontinent episodes between changes), rate of acquisition (a measure of the speed at which urine is drawn away from the skin by a product, product retention capacity (a measure of a product's capacity to hold fluid without rewetting the skin), sizing options, absorbency levels, product safety, closure technology, breathable zones (a measure of the air permeability across a textile-like fabric at a controlled differential pressure), and elasticity. The Council also set values for and recommended four quantifiable parameters, and the testing methodology associated with each, to help consumers and states

  3. Study on the coupling performance of a turboexpander compressor applied in cryogenic reverse Brayton air refrigerator

    International Nuclear Information System (INIS)

    Yang, Shanju; Chen, Shuangtao; Chen, Xingya; Zhang, Xingqun; Hou, Yu

    2016-01-01

    Highlights: • Numerical simulations on expansion and compression processes were carried out. • A coupling model was built based on analysis and simulation and verified by test. • Relations and interactions among coupling parameters were quantitatively described. • When T_0_C = 0.39 MPa, the cooling capacity of refrigerator reached 221 W at 129.6 K. - Abstract: A small cryogenic reverse Brayton air refrigerator with turboexpander compressor (TEC) is presented in this study. Because of stable process, simple matching between expander and brake blower, and easy regulation, a turboexpander with brake blower is usually used in small reverse Brayton refrigerator. However, a turboexpander with brake blower just consumes and wastes the output energy during the enthalpy drop. In contrast, the output energy of TEC is absorbed by its coupled compressor for recycling. Thus when employing a TEC, the reverse Brayton refrigerator will achieve lower refrigeration temperature, larger cooling capacity and more effective energy use. TEC overall performance, which has an important impact on the refrigerator thermal performance, is mainly determined by the coupling between expander and compressor. In a TEC, the compressor and expander should seek balance among energy, rotating speed, mass flow rate and pressure, though restricted by individual working characteristics. The coupling relations among compressor efficiency, expander efficiency, compressor pressure ratio and expander expansion ratio are quite complex. In this study, theoretical coupling analysis between expander and compressor was conducted. The aerodynamic performances of compressor and expander were calculated using CFX simulation with SST model. The performance curves of compressor and expander were obtained through simulation results, which were validated by experimental data. Based on the coupling analysis and numerical simulations, the automatic coupling model between compression process and expansion process

  4. Photovoltaic Device Performance Evaluation Using an Open-Hardware System and Standard Calibrated Laboratory Instruments

    Directory of Open Access Journals (Sweden)

    Jesús Montes-Romero

    2017-11-01

    Full Text Available This article describes a complete characterization system for photovoltaic devices designed to acquire the current-voltage curve and to process the obtained data. The proposed system can be replicated for educational or research purposes without having wide knowledge about electronic engineering. Using standard calibrated instrumentation, commonly available in any laboratory, the accuracy of measurements is ensured. A capacitive load is used to bias the device due to its versatility and simplicity. The system includes a common part and an interchangeable part that must be designed depending on the electrical characteristics of each PV device. Control software, developed in LabVIEW, controls the equipment, performs automatic campaigns of measurements, and performs additional calculations in real time. These include different procedures to extrapolate the measurements to standard test conditions and methods to obtain the intrinsic parameters of the single diode model. A deep analysis of the uncertainty of measurement is also provided. Finally, the proposed system is validated by comparing the results obtained from some commercial photovoltaic modules to the measurements given by an independently accredited laboratory.

  5. Heat transfer effects on the performance of an air standard Dual cycle

    International Nuclear Information System (INIS)

    Hou, S.-S.

    2004-01-01

    There are heat losses during the cycle of a real engine that are neglected in ideal air standard analysis. In this paper, the effects of heat transfer on the net work output and the indicated thermal efficiency of an air standard Dual cycle are analyzed. Heat transfer from the unburned mixture to the cylinder walls has a negligible effect on the performance for the compression process. Additionally, the heat transfer rates to the cylinder walls during combustion are the highest and extremely important. Therefore, we assume that the compression and power processes proceed instantaneously so that they are reversible adiabatics, and the heat losses during the heat rejection process can be neglected. The heat loss through the cylinder wall is assumed to occur only during combustion and is further assumed to be proportional to the average temperature of both the working fluid and the cylinder wall. The results show that the net work output versus efficiency characteristics and the maximum net work output and the corresponding efficiency bounds are strongly influenced by the magnitude of the heat transfer. Higher heat transfer to the combustion chamber walls lowers the peak temperature and pressure and reduces the work per cycle and the efficiency. The effects of other parameters, in conjunction with the heat transfer, including combustion constants, cut-off ratio and intake air temperature, are also reported. The results are of importance to provide good guidance for the performance evaluation and improvement of practical Diesel engines

  6. The case for improved HEPA-filter mechanical performance standards revisited

    Energy Technology Data Exchange (ETDEWEB)

    Ricketts, C.I.; Smith, P.R. [New Mexico State Univ., Las Cruces, NM (United States)

    1997-08-01

    Under benign operating conditions, High Efficiency Particulate Air (HEPA) filter units serve as reliable and relatively economical components in the air cleaning systems of nuclear facilities worldwide. Despite more than four decades of filter-unit evaluation and improvements, however, the material strength characteristics of the glass fiber filter medium continue to ultimately limit filter functional reliability. In worst-case scenarios involving fire suppression, loss-of-coolant accidents (LOCA`s), or exposure to shock waves or tornado induced flows, rupture of the filter medium of units meeting current qualification standards cannot be entirely ruled out. Even under so-called normal conditions of operation, instances of filter failure reported in the literature leave open questions of filter-unit reliability. Though developments of filter units with improved burst strengths have been pursued outside the United States, support for efforts in this country has been comparatively minimal. This despite user requests for filters with greater moisture resistance, for example. Or the fact that conventional filter designs result in not only the least robust component to be found in a nuclear air cleaning system, but also the one most sensitive to the adverse effects of conditions deviating from those of normal operation. Filter qualification-test specifications of current codes, standards, and regulatory guidelines in the United States are based primarily upon research performed in a 30-year period beginning in the 1950`s. They do not seem to reflect the benefits of the more significant developments and understanding of filter failure modes and mechanisms achieved since that time. One overseas design, based on such knowledge, has proven reliability under adverse operating conditions involving combined and serial challenges. Its widespread use, however, has faltered on a lack of consensus in upgrading filter performance standards. 34 refs., 2 figs., 3 tabs.

  7. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics-Three Decades of High-Quality, Technically-Rigorous Normalization

    Science.gov (United States)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high-quality, technically-rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards contain testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards are used to generate accurate, reliable, repeatable and complete data. Within Committee C28, users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, 50 standards since the Committee's founding in 1986. This paper provides a detailed retrospective of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of standards for advanced ceramics to demonstrate their practical applications.

  8. ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics, Three Decades of High-quality, Technically-rigorous Normalization

    Science.gov (United States)

    Jenkins, Michael G.; Salem, Jonathan A.

    2016-01-01

    Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high quality, rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards provide accurate, reliable, repeatable and complete data. Within Committee C28 users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, nearly 50 standards since the Committees founding in 1986. This paper provides a retrospective review of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of advanced ceramics standards to demonstrate their practical applications.

  9. Applying Importance-Performance Analysis as a Service Quality Measure in Food Service Industry

    OpenAIRE

    Tzeng, Gwo-Hshiung; Chang, Hung-Fan

    2011-01-01

    As the global economy becomes a service oriented economy, food service accounts for over 20% of service revenue, with an annual growth rate of more than 3%. Compared to physical products, service features are invisible, and the production and sale occurs simultaneously. There is not easy to measure the performance of service. Therefore, the service quality of catering services is considered to be an important topic of service management. According Market Intelligence & Consulting Institute (M...

  10. Web communication of CSR and financial performance: Study applied to catalan meat companies

    OpenAIRE

    Aramayo García, Alejandra; Arimany-Serrat, Nuria; Uribe Salazar, Clara; Sabata Aliberch, Anna

    2016-01-01

    Purpose: Understanding the relationship between CSR communication on corporate websites and the financial performance of Catalan meat companies. Design/methodology/approach: Qualitative and quantitative analysis of the CSR communication variables of corporate websites identifying the companies with the best CSR web communication’s practices, and economic and financial comparative analysis. It also modelled the financial returns to determine whether CSR communication, as an independent vari...

  11. Performance enhancement of microbial fuel cell by applying transient-state regulation

    International Nuclear Information System (INIS)

    Liang, Peng; Zhang, Changyong; Jiang, Yong; Bian, Yanhong; Zhang, Helan; Sun, Xueliang; Yang, Xufei; Zhang, Xiaoyuan; Huang, Xia

    2017-01-01

    Highlights: • MFC was operated with transient-state regulation to enhance its performance. • Effects of the TSR parameters on MFC performance were thoroughly investigated. • Long-term operation of MFC in TSR mode allowed 32.7% higher power production. • Anode capacitance helped reduce the MFC’s internal impedance in the TSR mode. - Abstract: A binder-free, pseudocapacitive anode was fabricated by coating reduced graphene oxide (rGO) and manganese oxide (MnO_2) nanoparticles on stainless steel fibre felt (SS). Microbial fuel cell (MFC) equipped with this novel anode yielded a maximum power density of 1045 mW m"−"2, 20 times higher than that of a similar MFC with a bare SS anode (46 mW m"−"2). Transient-state regulation (TSR) was implemented to further improve the MFC’s power generation. The optimal TSR duty cycle ranged from 67% to 95%, and the MFC’s power density increased with TSR frequency. A maximum power density output of 1238 mW m"−"2 was achieved at the TSR duty cycle of 75% and the frequency of 1 Hz, 18.4% greater than that obtained from the steady state operation. The TSR mode delivered better MFC performance especially when the external resistance was small. Long-term operation tests revealed that the current density and power density yielded in the TSR mode were on average 15.0% and 32.7% greater than those in the steady state mode, respectively. The TSR mode was believed to reduce the internal resistance of the MFC while enhance substrate mass transfer and electron transfer within the anode matrix, thereby improving the MFC performance.

  12. Ideal diet versus athletic performance: a study about nutritional stereotypes applied by triathletes

    Directory of Open Access Journals (Sweden)

    Patrícia Kanno

    2009-09-01

    Full Text Available Stereotype is a term designated to some generalized perceptions that people attri-bute to another individual, groups, objects and/or events. Objective: The purpose of this study was to evaluate the priorities that nutritionist and triathletes attributed to food to enhance the sport performance. Method: The sample was composed by 56 subjects, splited in two groups: Nutritionists (G1, n = 29 and Triathletes (G2, n = 27. The Intake Food Priority Question-naire (QPA, composed by food groups, was used to evaluate the importance of each food in the athletic performance. Results: To the data analysis, each food was grouped into one of the eight categories designed in nutrition pyramid. An arithmetic means were elaborated to categories and it was performed t tests for independent samples to compare nutritionists and triathletes priorities about each category. There were no differences between groups in Vegetables, Leguminous, Fruits and Sugar/Candies categories and, also, to the black coffee item. However, the triathletes overestimated the Cereals/Breads/Tubercle and Meat/Eggs categories and underestimated the Milk/Dairy Products and Oils/Fat categories. Conclusion: The triathletes overestimated some macronutrients (carbohydrates and proteins in detriment from another, like lipids.

  13. An applied artificial intelligence approach towards assessing building performance simulation tools

    Energy Technology Data Exchange (ETDEWEB)

    Yezioro, Abraham [Faculty of Architecture and Town Planning, Technion IIT (Israel); Dong, Bing [Center for Building Performance and Diagnostics, School of Architecture, Carnegie Mellon University (United States); Leite, Fernanda [Department of Civil and Environmental Engineering, Carnegie Mellon University (United States)

    2008-07-01

    With the development of modern computer technology, a large amount of building energy simulation tools is available in the market. When choosing which simulation tool to use in a project, the user must consider the tool's accuracy and reliability, considering the building information they have at hand, which will serve as input for the tool. This paper presents an approach towards assessing building performance simulation results to actual measurements, using artificial neural networks (ANN) for predicting building energy performance. Training and testing of the ANN were carried out with energy consumption data acquired for 1 week in the case building called the Solar House. The predicted results show a good fitness with the mathematical model with a mean absolute error of 0.9%. Moreover, four building simulation tools were selected in this study in order to compare their results with the ANN predicted energy consumption: Energy{sub 1}0, Green Building Studio web tool, eQuest and EnergyPlus. The results showed that the more detailed simulation tools have the best simulation performance in terms of heating and cooling electricity consumption within 3% of mean absolute error. (author)

  14. HTR-Based Power Plants’ Performance Analysis Applied on Conventional Combined Cycles

    Directory of Open Access Journals (Sweden)

    José Carbia Carril

    2015-01-01

    Full Text Available In high temperature reactors including gas cooled fast reactors and gas turbine modular helium reactors (GT-MHR specifically designed to operate as power plant heat sources, efficiency enhancement at effective cost under safe conditions can be achieved. Mentioned improvements concern the implementation of two cycle structures: (a, a stand alone Brayton operating with helium and a stand alone Rankine cycle (RC with regeneration, operating with carbon dioxide at ultrasupercritical pressure as working fluid (WF, where condensation is carried out at quasicritical conditions, and (b, a combined cycle (CC, in which the topping closed Brayton cycle (CBC operates with helium as WF, while the bottoming RC is operated with one of the following WFs: carbon dioxide, xenon, ethane, ammonia, or water. In both cases, an intermediate heat exchanger (IHE is proposed to provide thermal energy to the closed Brayton or to the Rankine cycles. The results of the case study show that the thermal efficiency, through the use of a CC, is slightly improved (from 45.79% for BC and from 50.17% for RC to 53.63 for the proposed CC with He-H2O operating under safety standards.

  15. Evaluation of linear accelerator performance standards using an outcome oriented approach

    International Nuclear Information System (INIS)

    Rangel, Alejandra; Ploquin, Nicolas; Kay, Ian; Dunscombe, Peter

    2008-01-01

    Radiation therapy, along with other branches of medicine, is moving towards a firmer basis in evidence to optimally utilize resources. As new treatment technology and strategies place greater demands on quality assurance resources, the need to objectively evaluate equipment and process performance standards from the perspective of predicted clinical impact becomes more urgent. This study evaluates the appropriateness of recommended quality control tolerance and action levels for linear accelerators based on the calculated dosimetric impact of suboptimal equipment performance. A method is described to quantify the dosimetric changes, as reflected by the changes in the outcome surrogate, equivalent uniform dose (EUD), of machine performance deviations from the optimal, specifically in the range of tolerance and action levels promulgated by the Canadian Association of Provincial Cancer Agencies (CAPCA). Linear accelerator performance deviations were simulated for the treatment of prostate, breast, lung, and brain using 3D conformal techniques, and the impact evaluated in terms of the changes in the EUD of the target volumes and two principal organs at risk (OARs) per site. The eight key performance characteristics examined are: Output constancy, beam flatness, gantry angle, collimator angle, field size indicator, laser alignment (three directions) and, by inference, the optical distance indicator. Currently accepted CAPCA tolerance levels for these eight performance characteristics are shown to maintain average EUD deviations to within 2% for the targets and 2 Gy for the OARs. However, within the 2% or 2 Gy range, the recommended tolerance levels are found to have markedly different effects on the EUDs of the structures of interest

  16. Performance Evaluation of Various STL File Mesh Refining Algorithms Applied for FDM-RP Process

    Science.gov (United States)

    Ledalla, Siva Rama Krishna; Tirupathi, Balaji; Sriram, Venkatesh

    2018-06-01

    Layered manufacturing machines use the stereolithography (STL) file to build parts. When a curved surface is converted from a computer aided design (CAD) file to STL, it results in a geometrical distortion and chordal error. Parts manufactured with this file, might not satisfy geometric dimensioning and tolerance requirements due to approximated geometry. Current algorithms built in CAD packages have export options to globally reduce this distortion, which leads to an increase in the file size and pre-processing time. In this work, different mesh subdivision algorithms are applied on STL file of a complex geometric features using MeshLab software. The mesh subdivision algorithms considered in this work are modified butterfly subdivision technique, loops sub division technique and general triangular midpoint sub division technique. A comparative study is made with respect to volume and the build time using the above techniques. It is found that triangular midpoint sub division algorithm is more suitable for the geometry under consideration. Only the wheel cap part is then manufactured on Stratasys MOJO FDM machine. The surface roughness of the part is measured on Talysurf surface roughness tester.

  17. Predicting biopharmaceutical performance of oral drug candidates - Extending the volume to dissolve applied dose concept.

    Science.gov (United States)

    Muenster, Uwe; Mueck, Wolfgang; van der Mey, Dorina; Schlemmer, Karl-Heinz; Greschat-Schade, Susanne; Haerter, Michael; Pelzetter, Christian; Pruemper, Christian; Verlage, Joerg; Göller, Andreas H; Ohm, Andreas

    2016-05-01

    The purpose of the study was to experimentally deduce pH-dependent critical volumes to dissolve applied dose (VDAD) that determine whether a drug candidate can be developed as immediate release (IR) tablet containing crystalline API, or if solubilization technology is needed to allow for sufficient oral bioavailability. pH-dependent VDADs of 22 and 83 compounds were plotted vs. the relative oral bioavailability (AUC solid vs. AUC solution formulation, Frel) in humans and rats, respectively. Furthermore, in order to investigate to what extent Frel rat may predict issues with solubility limited absorption in human, Frel rat was plotted vs. Frel human. Additionally, the impact of bile salts and lecithin on in vitro dissolution of poorly soluble compounds was tested and data compared to Frel rat and human. Respective in vitro - in vivo and in vivo - in vivo correlations were generated and used to build developability criteria. As a result, based on pH-dependent VDAD, Frel rat and in vitro dissolution in simulated intestinal fluid the IR formulation strategy within Pharmaceutical Research and Development organizations can be already set at late stage of drug discovery. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Calculation of the yearly energy performance of heating systems based on the European Building Energy Directive and related CEN Standards

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; de Carli, Michele

    2011-01-01

    According to the Energy Performance of Buildings Directive (EPBD) all new European buildings (residential, commercial, industrial, etc.) must since 2006 have an energy declaration based on the calculated energy performance of the building, including heating, ventilating, cooling and lighting syst......–20% of the building energy demand. The additional loss depends on the type of heat emitter, type of control, pump and boiler. Keywords: Heating systems; CEN standards; Energy performance; Calculation methods......According to the Energy Performance of Buildings Directive (EPBD) all new European buildings (residential, commercial, industrial, etc.) must since 2006 have an energy declaration based on the calculated energy performance of the building, including heating, ventilating, cooling and lighting...... systems. This energy declaration must refer to the primary energy or CO2 emissions. The European Organization for Standardization (CEN) has prepared a series of standards for energy performance calculations for buildings and systems. This paper presents related standards for heating systems. The relevant...

  19. Applying probabilistic well-performance parameters to assessments of shale-gas resources

    Science.gov (United States)

    Charpentier, Ronald R.; Cook, Troy

    2010-01-01

    In assessing continuous oil and gas resources, such as shale gas, it is important to describe not only the ultimately producible volumes, but also the expected well performance. This description is critical to any cost analysis or production scheduling. A probabilistic approach facilitates (1) the inclusion of variability in well performance within a continuous accumulation, and (2) the use of data from developed accumulations as analogs for the assessment of undeveloped accumulations. In assessing continuous oil and gas resources of the United States, the U.S. Geological Survey analyzed production data from many shale-gas accumulations. Analyses of four of these accumulations (the Barnett, Woodford, Fayetteville, and Haynesville shales) are presented here as examples of the variability of well performance. For example, the distribution of initial monthly production rates for Barnett vertical wells shows a noticeable change with time, first increasing because of improved completion practices, then decreasing from a combination of decreased reservoir pressure (in infill wells) and drilling in less productive areas. Within a partially developed accumulation, historical production data from that accumulation can be used to estimate production characteristics of undrilled areas. An understanding of the probabilistic relations between variables, such as between initial production and decline rates, can improve estimates of ultimate production. Time trends or spatial trends in production data can be clarified by plots and maps. The data can also be divided into subsets depending on well-drilling or well-completion techniques, such as vertical in relation to horizontal wells. For hypothetical or lightly developed accumulations, one can either make comparisons to a specific well-developed accumulation or to the entire range of available developed accumulations. Comparison of the distributions of initial monthly production rates of the four shale-gas accumulations that were

  20. A high performance Time-of-Flight detector applied to isochronous mass measurement at CSRe

    International Nuclear Information System (INIS)

    Mei Bo; Tu Xiaolin; Wang Meng; Xu Hushan; Mao Ruishi; Hu Zhengguo; Ma Xinwen; Yuan Youjin; Zhang Xueying; Geng Peng; Shuai Peng; Zang Yongdong; Tang Shuwen; Ma Peng; Lu Wan; Yan Xinshuai; Xia Jiawen; Xiao Guoqing; Guo Zhongyan; Zhang Hongbin

    2010-01-01

    A high performance Time-of-Flight detector has been designed and constructed for isochronous mass spectrometry at the experimental Cooler Storage Ring (CSRe). The detector has been successfully used in an experiment to measure the masses of the N∼Z∼33 nuclides near the proton drip-line. Of particular interest is the mass of 65 As. A maximum detection efficiency of 70% and a time resolution of 118±8 ps (FWHM) have been achieved in the experiment. The dependence of detection efficiency and signal average pulse height (APH) on atomic number Z has been studied. The potential of APH for Z identification has been discussed.

  1. A quantitative performance evaluation of the EM algorithm applied to radiographic images

    International Nuclear Information System (INIS)

    Brailean, J.C.; Sullivan, B.J.; Giger, M.L.; Chen, C.T.

    1991-01-01

    In this paper, the authors quantitatively evaluate the performance of the Expectation Maximization (EM) algorithm as a restoration technique for radiographic images. The perceived signal-to-noise ratio (SNR), of simple radiographic patterns processed by the EM algorithm are calculated on the basis of a statistical decision theory model that includes both the observer's visual response function and a noise component internal to the eye-brain system. The relative SNR (ratio of the processed SNR to the original SNR) is calculated and used as a metric to quantitatively compare the effects of the EM algorithm to two popular image enhancement techniques: contrast enhancement (windowing) and unsharp mask filtering

  2. Assessment of learning powered mobility use--applying grounded theory to occupational performance.

    Science.gov (United States)

    Nilsson, Lisbeth; Durkin, Josephine

    2014-01-01

    Collaboration by two grounded theory researchers, who each had developed a learning continuum instrument, led to the emergence of a new tool for assessment of learning powered mobility use. We undertook a rigorous process of comparative reanalysis that included merging, modifying, and expanding our previous research findings. A new instrument together with its facilitating strategies emerged in the course of revisits to our existing rich account of data taken from real environment powered mobility practice over an extensive time period. Instrument descriptors, categories, phases, and stages allow a facilitator to assess actual phase and plot actual occupational performance and provide a learner with the just right challenge through the learning process. Facilitating strategies are described for each of the phases and provide directions for involvement during learner performance. The learning approach is led by a belief system that the intervention is user-led, working in partnership and empowering the learner. The new assessment tool is inclusive of every potential powered mobility user because it focuses on the whole continuum of the learning process of powered mobility use from novice to expert. The new tool was appraised by clinicians and has been used successfully in clinical practice in the United Kingdom and Sweden.

  3. A Study of Performance Output of a Multivane Air Engine Applying Optimal Injection and Vane Angles

    Directory of Open Access Journals (Sweden)

    Bharat Raj Singh

    2012-01-01

    Full Text Available This paper presents a new concept of the air engine using compressed air as the potential power source for motorbikes, in place of an internal combustion engine. The motorbike is proposed to be equipped with an air engine, which transforms the energy of the compressed air into mechanical motion energy. A mathematical model is presented here, and performance evaluation is carried out on an air-powered novel air turbine engine. The maximum power output is obtained as 3.977 kW (5.50 HP at the different rotor to casing diameter ratios, optimal injection angle 60°, vane angle 45° for linear expansion (i.e., at minimum air consumption when the casing diameter is kept 100 mm, at injection pressure 6 bar (90 psi and speed of rotation 2500 rpm. A prototype air engine is built and tested in the laboratory. The experimental results are also seen much closer to the analytical values, and the performance efficiencies are recorded around 70% to 95% at the speed of rotation 2500–3000 rpm.

  4. Performance Modeling Applied to the Treatment and Disposal of a Mixed Waste at the SRS

    International Nuclear Information System (INIS)

    Pickett, J.B.; Jantzen, C.M.; Cook, J.R.; Whited, A.R.; Field, R.A.

    1997-05-01

    Performance modeling for Low Level Mixed Waste disposal was conducted using the measured leach rates from a number of vitrified waste formulations. The objective of the study was to determine if the improved durability of a vitrified mixed waste would allow trench disposal at the Savannah River Site (SRS). Leaching data were compiled from twenty-nine diverse reference glasses, encompassing a wide range of exposed glass surface area to leachant volume ratios (SA/V), and various leachant solutions; all of which had been leached at 90 degrees Celsius, using the MCC-1 or PCT procedures (ASTM Procedures C1220-92 and C1285-94, respectively). The normalized leach rates were scaled to the ambient disposal temperature of 25 degrees Celsius, and compared to the allowable leach rate of uranium - which would meet the performance assessment requirements. The results indicated that a glass of above average durability (vs. the reference glasses) would meet the uranium leaching concentration for direct SRS trench disposal

  5. Performance of an online translation tool when applied to patient educational material.

    Science.gov (United States)

    Khanna, Raman R; Karliner, Leah S; Eck, Matthias; Vittinghoff, Eric; Koenig, Christopher J; Fang, Margaret C

    2011-11-01

    Language barriers may prevent clinicians from tailoring patient educational material to the needs of individuals with limited English proficiency. Online translation tools could fill this gap, but their accuracy is unknown. We evaluated the accuracy of an online translation tool for patient educational material. We selected 45 sentences from a pamphlet available in both English and Spanish, and translated it into Spanish using GoogleTranslate™ (GT). Three bilingual Spanish speakers then performed a blinded evaluation on these 45 sentences, comparing GT-translated sentences to those translated professionally, along four domains: fluency (grammatical correctness), adequacy (information preservation), meaning (connotation maintenance), and severity (perceived dangerousness of an error if present). In addition, evaluators indicated whether they had a preference for either the GT-translated or professionally translated sentences. The GT-translated sentences had significantly lower fluency scores compared to the professional translation (3.4 vs. 4.7, P educational material, GT performed comparably to professional human translation in terms of preserving information and meaning, though it was slightly worse in preserving grammar. In situations where professional human translations are unavailable or impractical, online translation may someday fill an important niche. Copyright © 2011 Society of Hospital Medicine.

  6. ANALYSIS OF THE PREDICTIVE DMC CONTROLLER PERFORMANCE APPLIED TO A FEED-BATCH BIOREACTOR

    Directory of Open Access Journals (Sweden)

    J. A. D. RODRIGUES

    1997-12-01

    Full Text Available Two control algorithms were implemented in the stabilization of the dissolved oxygen concentration of the penicillin process production phase. A deterministic and nonstructured mathematical model was used, where were considered the balances of cell, substrate, dissolved oxygen and product formation as well as kinetic of the growth, respiration, product inhibition due to excess of substrate, penicillin hydrolyze, yield factors among cell growth, substrate consumption and dissolved oxygen consumption. The bioreactor was operated in a feed-batch way using an optimal strategy for the operational policy. The agitation speed was used as manipulated variable in order to achieve the dissolved oxygen control because it was found to be the most sensitive one. Two types of control configurations were implemented. First, the PID feedback control with the parameters estimated through Modified Simplex optimization method using the IAE index, and second, the DMC predictive control that had as control parameters the model, prediction and control horizons as well as suppression factor and the trajectory parameter. A sensitivity analysis of these two control algorithms was performed using the sample time and dead time as the index to make stability evaluation. Both configurations showed stable performance, however, the predictive one was found to be more robust in relation to the sample time, as well as the dead time variations. This is a very important characteristic to be considered for the implementation of control scheme in real fermentative process

  7. Plasma Treatment of Carbon Nanotubes Applied to Improve the High Performance of Carbon Nanofiber Supercapacitors

    International Nuclear Information System (INIS)

    Chang, Wei-Min; Wang, Cheng-Chien; Chen, Chuh-Yung

    2015-01-01

    Graphical abstract: This article focused on improving conductivity of carbon nanofibers (CNFs) by added plasma-treatment carbon nanotubes (CNTs). The plasma modification method avoided the destruction of the length and structure of the CNTs and maintained their good electrical properties. Through this method, the relation between conductivity and surface activity site of CNFs was investigated. The results shown that he CNTs-MA added to the CNFs successfully maintained the activity sites on the surface of the CNFs and provide a good electric network to enhance the supercapacitor performance of the CNFs. - Highlights: • The plasma modification method avoided the destruction of the length and structure of the CNTs and maintained their good electrical properties. • The highest conductivity of the CNTs-MA/CNF was 5.2 s/cm at 2.5 wt.% of CNTs-MA addition. It was increased to 8.7 time. • The CNTs-MA added to the CNFs successfully maintained the activity sites on the surface of the CNFs and provide a good electric network to enhance the supercapacitor performance of the CNFs. The highest capacitance was 382 F/g. - Abstract: Plasma-treatment carbon nanotubes (CNTs) grafted with maleic anhydride (MA) were embedded in polyacryonitrile nanofibers via electrospinning and subsequently carbonizated at 800 °C to fabricate carbon nanofibers (CNFs). The grafted degree of MA on CNTs (CNTs-MA) was determined via Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. The morphology, surface composition and conductivity of the CNTs-MA/CNF were characterized using electron microscopy, X-ray photoelectron and electrochemical impedance spectroscopy, respectively. CNTs-MA not only affected the conductivity of the CNFs but also the types of the nitrogen functional groups that could be represented as active sites on the CNFs to enhance the performance of the supercapacitors. When 2.5 wt.% CNTs-MA was embedded in the CNFs, the highest conductivity was obtained at

  8. Thermodynamic Simulation on the Performance of Twin Screw Expander Applied in Geothermal Power Generation

    Directory of Open Access Journals (Sweden)

    Yuanqu Qi

    2016-08-01

    Full Text Available A three-dimensional (3D geometry model of twin screw expander has been developed in this paper to measure and analyze geometric parameters such as groove volume, suction port area, and leakage area, which can be described as functions of rotation angle of male rotor. Taking the suction loss, leakage loss, and real gas effect into consideration, a thermodynamic model is developed using continuity and energy conservation equation. The developed model is verified by comparing predicted results of power output and internal efficiency with experimental data. Based on the model, the relationship between mass flow rate through inlet port and leakage path with rotation angle of male rotor as well as effects of the inlet parameter and operating parameter on the performance of the expander are analyzed.

  9. APPLIED BEHAVIORAL FINANCE: INVESTOR BIASES, PERFORMANCE REVERSION TO THE MEAN and TREND FORMATION

    Directory of Open Access Journals (Sweden)

    ADRIAN MITROI

    2014-02-01

    Full Text Available In the pursuit of understanding the behavior of the market player, the basic argument relays on the supposition that the risk appetite increases exactly at the worst moment - when the capacity to assume additional risk decreases significantly.People view a sample randomly drawn from a population as highly representative and cvasi similar to the population in all its essential characteristics. They expect any two samples drawn from a particular population to be more similar to one another and to the population than is statistically justifiable. This behavior is different from the tenets of classic finance theory. The paper aims at demonstating that investor psychological biases lead to investment performance to tilt to the mean in the long run and by following the trend, the financial market population do not enjoy significant sustainable benefits. As a reflection of the behavioral biases and influences, the statistical demonstration supports the conclusion that markets do not random walk.

  10. Web communication of CSR and financial performance: Study applied to catalan meat companies

    Directory of Open Access Journals (Sweden)

    Alejandra Aramayo García

    2016-02-01

    Full Text Available Purpose: Understanding the relationship between CSR communication on corporate websites and the financial performance of Catalan meat companies. Design/methodology/approach: Qualitative and quantitative analysis of the CSR communication variables of corporate websites identifying the companies with the best CSR web communication’s practices, and economic and financial comparative analysis. It also modelled the financial returns to determine whether CSR communication, as an independent variable, affects the net profit generated in relation to the investment of the stakeholders.  The analysis covered a sample of 130 Catalan meat companies. Findings: The report provides a diagnosis of the CSR web communication and also of the financial health of the companies in the period analyzed. The study contributes to the discussion on the relationship between CSR and financial performance. Research limitations/implications: It would be desirable extended periods of economic and financial analysis, and a more in depth study of online communication strategy incorporating the views of those responsible for the strategy and stakeholders. Practical implications: The analysis provides a better understanding of current corporate web communication and the economic and financial situation of the companies analyzed. It has practical benefits in making strategic decisions to improve the relationship with stakeholders and allows us to assess the forecast that has been made for this sector in Catalonia in the period analyzed. Social implications: The results of the study allow the industry to see the future prospects of this sector and to make the necessary changes. The results lead to improved transparency and responsible behavior. Originality/value: The analysis allows the stakeholders of the meat industry to evaluate the company’s social behavior, to assess the financial health and to take appropriate future actions.

  11. Life cycle performances of log wood applied for soil bioengineering constructions

    Science.gov (United States)

    Kalny, Gerda; Strauss-Sieberth, Alexandra; Strauss, Alfred; Rauch, Hans Peter

    2016-04-01

    Nowadays there is a high demand on engineering solutions considering not only technical aspects but also ecological and aesthetic values. Soil bioengineering is a construction technique that uses biological components for hydraulic and civil engineering solutions. Soil bioengineering solutions are based on the application of living plants and other auxiliary materials including among others log wood. This kind of construction material supports the soil bioengineering system as long as the plants as living construction material overtake the stability function. Therefore it is important to know about the durability and the degradation process of the wooden logs to retain the integral performance of a soil bio engineering system. These aspects will be considered within the framework of the interdisciplinary research project „ELWIRA Plants, wood, steel and concrete - life cycle performances as construction materials". Therefore field investigations on soil bioengineering construction material, specifically European Larch wood logs, of different soil bioengineering structures at the river Wien have been conducted. The drilling resistance as a parameter for particular material characteristics of selected logs was measured and analysed. The drilling resistance was measured with a Rinntech Resistograph instrument at different positions of the wooden logs, all surrounded with three different backfills: Fully surrounded with air, with earth contact on one side and near the water surface in wet-dry conditions. The age of the used logs ranges from one year old up to 20 year old. Results show progress of the drilling resistance throughout the whole cross section as an indicator to assess soil bioengineering construction material. Logs surrounded by air showed a higher drilling resistance than logs with earth contact and the ones exposed to wet-dry conditions. Hence the functional capability of wooden logs were analysed and discussed in terms of different levels of degradation

  12. Water spray cooling technique applied on a photovoltaic panel: The performance response

    International Nuclear Information System (INIS)

    Nižetić, S.; Čoko, D.; Yadav, A.; Grubišić-Čabo, F.

    2016-01-01

    Highlights: • An experimental study was conducted on a monocrystalline photovoltaic panel (PV). • A water spray cooling technique was implemented to determine PV panel response. • The experimental results showed favorable cooling effect on the panel performance. • A feasibility aspect of the water spray cooling technique was also proven. - Abstract: This paper presents an alternative cooling technique for photovoltaic (PV) panels that includes a water spray application over panel surfaces. An alternative cooling technique in the sense that both sides of the PV panel were cooled simultaneously, to investigate the total water spray cooling effect on the PV panel performance in circumstances of peak solar irradiation levels. A specific experimental setup was elaborated in detail and the developed cooling system for the PV panel was tested in a geographical location with a typical Mediterranean climate. The experimental result shows that it is possible to achieve a maximal total increase of 16.3% (effective 7.7%) in electric power output and a total increase of 14.1% (effective 5.9%) in PV panel electrical efficiency by using the proposed cooling technique in circumstances of peak solar irradiation. Furthermore, it was also possible to decrease panel temperature from an average 54 °C (non-cooled PV panel) to 24 °C in the case of simultaneous front and backside PV panel cooling. Economic feasibility was also determined for of the proposed water spray cooling technique, where the main advantage of the analyzed cooling technique is regarding the PV panel’s surface and its self-cleaning effect, which additionally acts as a booster to the average delivered electricity.

  13. Evaluation of a device for standardized measurements of reading performance in a prepresbyopic population.

    Science.gov (United States)

    Arad, Tschingis; Baumeister, Martin; Bühren, Jens; Kohnen, Thomas

    2017-04-20

    Automated measurements of reading performance are required for clinical trials involving presbyopia-correcting surgery options. Repeatability of a testing device for reading (Salzburg Reading Desk) was evaluated in a prepresbyopic population. Subjective reading performance of 50 subjects divided into 2 age groups (23-30 years and 38-49 years) with distance-corrected eyes was investigated with different log-scaled reading charts. At study entry, refractive parameters were measured and distance visual acuity assessed. Two standardized binocular measurements were performed for each subject (32.24 ± 9.87 days apart [mean ± SD]). The repeatability of the tests was estimated using correlation coefficients, Wilcoxon signed-rank test, and Bland-Altman method. The test parameters at both maximum reading rate (MRR) measurements demonstrate a strong relationship of age group 2 subjects (correlation coefficient [r] = 0.74 p = 10-4) and of younger subjects (age group 1: r = 0.69, p = 10-4). Prepresbyopic subjects of age group 2 showed moderate results for near reading distance (r = 0.67, p = 10-4); by contrast, younger subjects had poorer results (r = 0.55, p = 10-3). The Wilcoxon signed-rank test revealed agreement between measurements and Bland-Altman plots showed a wide data spread for MRR and near reading distance in both groups. The device measures repeatedly selected reading performance parameters of near real world conditions, such as MRR, in prepresbyopic populations if several factors are taken into account. The option to choose preferred distance leads to more variance in measuring repeated reading performance. German Clinical Trials Register (DRKS) registration reference number: DRKS00000784.

  14. Novel surgical performance evaluation approximates Standardized Incidence Ratio with high accuracy at simple means.

    Science.gov (United States)

    Gabbay, Itay E; Gabbay, Uri

    2013-01-01

    Excess adverse events may be attributable to poor surgical performance but also to case-mix, which is controlled through the Standardized Incidence Ratio (SIR). SIR calculations can be complicated, resource consuming, and unfeasible in some settings. This article suggests a novel method for SIR approximation. In order to evaluate a potential SIR surrogate measure we predefined acceptance criteria. We developed a new measure - Approximate Risk Index (ARI). "Number Needed for Event" (NNE) is the theoretical number of patients needed "to produce" one adverse event. ARI is defined as the quotient of the group of patients needed for no observed events Ge by total patients treated Ga. Our evaluation compared 2500 surgical units and over 3 million heterogeneous risk surgical patients that were induced through a computerized simulation. Surgical unit's data were computed for SIR and ARI to evaluate compliance with the predefined criteria. Approximation was evaluated by correlation analysis and performance prediction capability by Receiver Operating Characteristics (ROC) analysis. ARI strongly correlates with SIR (r(2) = 0.87, p 0.9) 87% sensitivity and 91% specificity. ARI provides good approximation of SIR and excellent prediction capability. ARI is simple and cost-effective as it requires thorough risk evaluation of only the adverse events patients. ARI can provide a crucial screening and performance evaluation quality control tool. The ARI method may suit other clinical and epidemiological settings where relatively small fraction of the entire population is affected. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  15. Proposal for implementation risk management according ABNT NBR ISO 31000 standard applied to internal audit process of Integrated Management System of IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Scapin Junior, Wilson S.; Salvetti, Tereza C.; Longo, Guilherme C., E-mail: wsscapin@ipen.br, E-mail: salvetti@ipen.br, E-mail: glongo@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The paper objective is to establish a risk management methodology applied to internal audits processes of IPEN Integrated Management System (IMS). In continuous seeking of updating methodologies to assist effective management based on the constant changes in the organizational world, and the development of management tools used for decision making, risk management demonstrates trends to be a new tool with high efficiency. This trend is accentuated by the fact that risk management is being incorporated into the new revision of quality management standard ISO 9001, estimated conclusion in November 2015. The identification, evaluation and treatment of risks are present in eleven items of its ten requirements at new revision. From the conclusion of the review, all organizations certified by that standard should make the necessary changes in their systems to meet the new requirements. This proposal will provide anticipate the changes that will occur in the management system of IPEN in accordance with this new revision. With the character of a pilot program to implement the organizational culture change in relationship to new concepts related to risks and implementation of risk management all other system processes that will be affected by the new revision of this standard. The methodology used for this paper is supported by the standards ABNT NBR ISO 31000. (author)

  16. Brazilian and International Accounting Standards Applied to the Public Sector and the Challenge of Convergence: a Comparative Analysis - IPSAS and NBCTSP

    Directory of Open Access Journals (Sweden)

    Adriana Rodrigues Fragoso

    2012-01-01

    Full Text Available The aim in this study is to analyze the current stage of conceptual convergence between Brazilian accounting standardsapplied to the public sector (NBCTSP and the International Public Sector Accounting Standard (IPSAS.The complexity and range of transactions between public or private sector entities, as a result of market internationalization,demand continuous and dynamic assessment of the events that promote quantitative or qualitative equitychanges. For this evaluation process, observing accounting principles and standards is important to guarantee, amongother information characteristics, understandability and comparability, thus reducing costs for investors and users in general, in view of the barriers raised by diverse languages, cultures, tax and economic policies. For convergenceanalysis, the standards’ contents were subject to a comparative study, based on a descriptive analysis, with a viewto verifying the existing adherence between Brazilian and international standards applied to the public sector. Theresults found highlight that different aspects still have to be discussed with a view to an actual convergence with theinternational standards; the current convergence is partial. The high-quality conceptual exposure of the NBCPSPsis observed though, while the contents of the IPSAS are more focused on operating procedures.

  17. Proposal for implementation risk management according ABNT NBR ISO 31000 standard applied to internal audit process of Integrated Management System of IPEN

    International Nuclear Information System (INIS)

    Scapin Junior, Wilson S.; Salvetti, Tereza C.; Longo, Guilherme C.

    2015-01-01

    The paper objective is to establish a risk management methodology applied to internal audits processes of IPEN Integrated Management System (IMS). In continuous seeking of updating methodologies to assist effective management based on the constant changes in the organizational world, and the development of management tools used for decision making, risk management demonstrates trends to be a new tool with high efficiency. This trend is accentuated by the fact that risk management is being incorporated into the new revision of quality management standard ISO 9001, estimated conclusion in November 2015. The identification, evaluation and treatment of risks are present in eleven items of its ten requirements at new revision. From the conclusion of the review, all organizations certified by that standard should make the necessary changes in their systems to meet the new requirements. This proposal will provide anticipate the changes that will occur in the management system of IPEN in accordance with this new revision. With the character of a pilot program to implement the organizational culture change in relationship to new concepts related to risks and implementation of risk management all other system processes that will be affected by the new revision of this standard. The methodology used for this paper is supported by the standards ABNT NBR ISO 31000. (author)

  18. Analysis the Appropriate using Standard Costing Applying in Land Cost Component of Real Estate Development Activities: A Case Study of PT Subur Agung

    Directory of Open Access Journals (Sweden)

    Elfrida Yanti

    2011-05-01

    Full Text Available Standard cost is generally used by manufacturing business, which direct material, labor, and factory overhead are cleared allocated. On real estate business in this case PT Subur Agung use standard cost based on three costs, raw land, land improvement and interest expense categories instead of direct material, direct labor and overhead. Developer use these cost to predict the project cost and estimate the pre-selling price, in accordance with the cost estimation classification matrix, the variance range is in the expected accuracy rate by testing the variance percentage between standard cost and actual cost. The additional similar projects in PT Subur Agung also follow the same scope. All these evidences have proved the appropriate using standard costing in land cost component of real estate development activities but how it applies this article will analyze in this particular project with using descriptive and exploratory method. The analysis started by knowing the conceptual situation of PT Subur Agung and the data was presented in tables and calculation with detail explanation. 

  19. Neonatal mannequin comparison of the Upright self-inflating bag and snap-fit mask versus standard resuscitators and masks: leak, applied load and tidal volumes.

    Science.gov (United States)

    Rafferty, Anthony Richard; Johnson, Lucy; Davis, Peter G; Dawson, Jennifer Anne; Thio, Marta; Owen, Louise S

    2017-11-30

    Neonatal mask ventilation is a difficult skill to acquire and maintain. Mask leak is common and can lead to ineffective ventilation. The aim of this study was to determine whether newly available neonatal self-inflating bags and masks could reduce mask leak without additional load being applied to the face. Forty operators delivered 1 min episodes of mask ventilation to a mannequin using the Laerdal Upright Resuscitator, a standard Laerdal infant resuscitator (Laerdal Medical) and a T-Piece Resuscitator (Neopuff), using both the Laerdal snap-fit face mask and the standard Laerdal size 0/1 face mask (equivalent sizes). Participants were asked to use pressure sufficient to achieve 'appropriate' chest rise. Leak, applied load, airway pressure and tidal volume were measured continuously. Participants were unaware that load was being recorded. There was no difference in mask leak between resuscitation devices. Leak was significantly lower when the snap-fit mask was used with all resuscitation devices, compared with the standard mask (14% vs 37% leak, Pmask was preferred by 83% of participants. The device-mask combinations had no significant effect on applied load. The Laerdal Upright Resuscitator resulted in similar leak to the other resuscitation devices studied, and did not exert additional load to the face and head. The snap-fit mask significantly reduced overall leak with all resuscitation devices and was the mask preferred by participants. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. [Performance of a standardized interrogation to improve the screening of Chlamydia trachomatis infection].

    Science.gov (United States)

    Grandcolin, S; de Hauteclocque, A; Lafoscade, A; Fritel, X

    2015-10-01

    To estimate the performance of a standardized interrogation tool facilitating the detection and screening of patients for the Chlamydia trachomatis infection, to estimate the prevalence of the infection in the family planning population studied. Prospective observational study, including the patients who had a consultation in the abortion center in the CHU of Poitiers. A sampling of the cervix was systematically carried out after the standardized interrogation in search of four clinical signs. The samples were analyzed by genetic amplification. Three hundred and eighty-six women were included and 56 (14.5 %) infections were identified. The medical history questionnaire was relatively effective for 2 or 3 clinical signs. The positive predictive value (PPV) was respectively 34.8 % and 53.8 % and was very relevant for 4 clinical signs with PPV at 83.3 % [CI 95 %: 74-93 %]. Among the infected women, 48.2 % had no clinical sign revealed by the medical history questionnaire. The presence of any clinical sign was strongly associated with the C. trachomatis infection (Pinterrogation are all significantly associated with the C. trachomatis infection. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  1. Analysis of the existing Standard on Power performance measurement and its application in complex terrain

    International Nuclear Information System (INIS)

    Cuerva, A.

    1997-01-01

    There are some groups working on the improvement of the existing Standard and recommendation on WECS power performance measurement and analysis. One of them, besides the one working in this project, is the MEASNET expert group. This one is trying to adequate the main reference, the IEC1400-12 Ref. [9]. to the current requirements on technical quality and trueness. Within this group and the MEASNET one, many deficiencies have been detected in the procedure followed up to now. Several of them belong to general aspects of the method (calculations, assumptions, etc. ) but the most critical fact regards to the inherent characteristics of complex terrain and to the issue of site calibration and uncertainties due to it, specifically. (Author)

  2. The IEEE 1355 Standard. Developments, performance and application in high energy physics

    International Nuclear Information System (INIS)

    Haas, S.

    1998-12-01

    The data acquisition systems of the next generation High Energy Physics experiments at the Large Hadron Collider (LHC) at CERN will rely on high-speed point-to-point links and switching networks for their higher level trigger and event building systems. This thesis provides a detailed evaluation of the DS-Link and switch technology, which is based on the IEEE 1355 standard for Heterogeneous Interconnect (HIC). The DS-Link is a bidirectional point-to-point serial interconnect, operating at speeds up to 200 MBaud. The objective of this thesis was to study the performance of the IEEE 1355 link and switch technology and to demonstrate that switching networks using this technology would scale to meet the requirements of the High Energy Physics applications

  3. Analysis of the existing Standard on Power performance measurement and its application in complex terrain

    Energy Technology Data Exchange (ETDEWEB)

    Cuerva, A.

    1997-10-01

    There are some groups working on the improvement of the existing Standard and recommendation on WECS power performance measurement and analysis. One of them, besides the one working in this project, is the MEASNET expert group. This one is trying to adequate the main reference, the IEC 1400-12 Re.[9]. to the current requirements on technical quality and trueness. Within this group and the MEASNET one, many deficiencies have been detected in the procedure followed up to now. Several of them belong to general aspects of the method (calculations, assumptions, etc.) but the most critical fact regards to the inherent characteristics of complex terrain and to the issue of site calibration and uncertainties due to it, specifically. (Author)

  4. The Effects of Dextromethorphan on Driving Performance and the Standardized Field Sobriety Test.

    Science.gov (United States)

    Perry, Paul J; Fredriksen, Kristian; Chew, Stephanie; Ip, Eric J; Lopes, Ingrid; Doroudgar, Shadi; Thomas, Kelan

    2015-09-01

    Dextromethorphan (DXM) is abused most commonly among adolescents as a recreational drug to generate a dissociative experience. The objective of the study was to assess driving with and without DXM ingestion. The effects of one-time maximum daily doses of DXM 120 mg versus a guaifenesin 400 mg dose were compared among 40 healthy subjects using a crossover design. Subjects' ability to drive was assessed by their performance in a driving simulator (STISIM® Drive driving simulator software) and by conducting a standardized field sobriety test (SFST) administered 1-h postdrug administration. The one-time dose of DXM 120 mg did not demonstrate driving impairment on the STISIM® Drive driving simulator or increase SFST failures compared to guaifenesin 400 mg. Doses greater than the currently recommended maximum daily dose of 120 mg are necessary to perturb driving behavior. © 2015 American Academy of Forensic Sciences.

  5. Seismic Performance Comparison of a High-Content SDA Frame and Standard RC Frame

    Directory of Open Access Journals (Sweden)

    John W. van de Lindt

    2011-01-01

    Full Text Available This study presents the method and results of an experiment to study the seismic behavior of a concrete portal frame with fifty percent of its cement content replaced with a spray dryer ash (SDA. Based on multiple-shake-table tests, the high content SDA frame was found to perform as well as the standard concrete frame for two earthquakes exceeding design-level intensity earthquakes. Hence, from a purely seismic/structural standpoint, it may be possible to replace approximately fifty percent of cement in a concrete mix with SDA for the construction of structural members in high seismic zones. This would help significantly redirect spray dryer ash away from landfills, thus, providing a sustainable greener alternative to concrete that uses only Portland cement, or only a small percentage of SDA or fly ash.

  6. How to improve the standardization and the diagnostic performance of the fecal egg count reduction test?

    DEFF Research Database (Denmark)

    Levecke, Bruno; Kaplan, Ray M.; Thamsborg, Stig M.

    2018-01-01

    Although various studies have provided novel insights into how to best design, analyze and interpret a fecal egg count reduction test (FECRT), it is still not straightforward to provide guidance that allows improving both the standardization and the analytical performance of the FECRT across...... a variety of both animal and nematode species. For example, it has been suggested to recommend a minimum number of eggs to be counted under the microscope (not eggs per gram of feces), but we lack the evidence to recommend any number of eggs that would allow a reliable assessment of drug efficacy. Other...... the UI methodology that yields the most reliable assessment of drug efficacy (coverage of TDE) and detection of reduced drug efficacy, and (iii) to determine the required sample size and number of eggs counted under the microscope that optimizes the detection of reduced efficacy. Our results confirm...

  7. Performance test on 2-dimensional PIV and 3-dimensional PIV using standard images

    International Nuclear Information System (INIS)

    Hwang, Tae Gyu; Doh, Deog Hee

    2004-01-01

    Quantitative performance test on the conventional 2D-PIV and the hybrid angular 3D-PIV (Stereoscopic PIV) was carried out. LES Data sets on an impinging jet which are provided on the webpage(http://www.vsj.or.jp/piv) for the PIV Standard Project were used for the generation of virtual images. The generated virtual images were used for the 2D-PIV and 3D-PIV measurements test. It has been shown that the results obtained by 2D-PIV on average values are slightly closer to the LES data than those obtained by 3D-PIV, but the turbulent properties obtained by 2D-PIV are largely underestimated than those obtained by 3D-PIV

  8. Improved performance of the microbial electrolysis desalination and chemical-production cell with enlarged anode and high applied voltages.

    Science.gov (United States)

    Ye, Bo; Luo, Haiping; Lu, Yaobin; Liu, Guangli; Zhang, Renduo; Li, Xiao

    2017-11-01

    The aim of this study was to improve performance of the microbial electrolysis desalination and chemical-production cell (MEDCC) using enlarged anode and high applied voltages. MEDCCs with anode lengths of 9 and 48cm (i.e., the 9cm-anode MEDCC and 48cm-anode MEDCC, respectively) were tested under different voltages (1.2-3.0V). Our results demonstrated for the first time that the MEDCC could maintain high performance even under the applied voltage higher than that for water dissociation (i.e., 1.8V). Under the applied voltage of 2.5V, the maximum current density in the 48cm-anode MEDCC reached 32.8±2.6A/m 2 , which is one of the highest current densities reported so far in the bioelectrochemical system (BES). The relative abundance of Geobacter was changed along the anode length. Our results show the great potential of the BES with enlarged anode and high applied voltages. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. EMPIRICAL MODELS FOR PERFORMANCE OF DRIPPERS APPLYING CASHEW NUT PROCESSING WASTEWATER

    Directory of Open Access Journals (Sweden)

    KETSON BRUNO DA SILVA

    2016-01-01

    Full Text Available The objective of this work was to develop empirical models for hydraulic performance of drippers operating with cashew nut processing wastewater depending on operating time, operating pressure and effluent quality. The experiment consisted of two factors, types of drippers (D1=1.65 L h-1, D2=2.00 L h-1 and D3=4.00 L h-1, and operating pressures (70, 140, 210 and 280 kPa, with three replications. The flow variation coefficient (FVC, distribution uniformity coefficient (DUC and the physicochemical and biological characteristics of the effluent were evaluated every 20 hours until complete 160 hours of operation. Data were interpreted through simple and multiple linear stepwise regression models. The regression models that fitted to the FVC and DUC as a function of operating time were square root, linear and quadratic, with 17%, 17% and 8%, and 17%, 17% and 0%, respectively. The regression models that fitted to the FVC and DUC as a function of operating pressures were square root, linear and quadratic, with 11%, 22% and 0% and the 0%, 22% and 11%, respectively. Multiple linear regressions showed that the dissolved solids content is the main wastewater characteristic that interfere in the FVC and DUC values of the drip units D1 (1.65 L h-1 and D3 (4.00 L h-1, operating at work pressure of 70 kPa (P1.

  10. Applying integrated software to optimize corporate production performance: a case study at Suncor

    International Nuclear Information System (INIS)

    Masse, L.P.; Rhynes, P.

    1997-01-01

    The feasibility and need to introduce a central database of basic well data for use in the petroleum industry in order to enhance production performance was discussed. Suncor developed a central database of well data as the foundation for a future systems architecture for its own use. The perceived, current and future benefits of such a system were described. Suncor identified the need for a corporate repository which is accessible to multiple applications, and provides the opportunity to upgrade the system to new technology that will benefit from integration. The objective was to document existing data sets, identify what additional data would be useful and document existing processes around this well data. The integrated set of data is supplied by multiple vendors and includes public land data, production budget, public well data, forecasting, economics, drilling, procurement system, fixed assets, maintenance, land administration, field data capture, production accounting and financial accounting. In addition to being able to access the current well data, significant added value is expected from the pro-active communication within the departments, and the additional time available for analysis and decisions as opposed to searching for data and comparing sources. 4 figs

  11. Performance of bioaugmentation-assisted phytoextraction applied to metal contaminated soils: A review

    International Nuclear Information System (INIS)

    Lebeau, Thierry; Braud, Armelle; Jezequel, Karine

    2008-01-01

    Bioaugmentation-assisted phytoextraction is a promising method for the cleaning-up of soils contaminated by metals. Bacteria mainly Plant Growth Promoting Rhizobacteria (PGPR) and fungi mainly Arbuscular Mycorrhizal Fungi (AMF) associated with hyperaccumulating or non-hyperaccumulating plants were analyzed on the basis of a bioprocess engineering approach (concentration and amount of metals extracted by plants, translocation and bioconcentration factor, and plant biomass). In average bioaugmentation increased metals accumulated by shoots by a factor of about 2 (metal concentration) and 5 (amount) without any obvious differences between bacteria and fungi. To optimize this process, new relevant microorganism-plant associations and field scale experiments are needed along with a common methodology for the comparison of all experiments on the same basis. Recommendations were suggested concerning both the microbial-plant selection and the implementation of bioaugmentation to enhance the microbial survival. The use of microbial consortia associated with plant was discussed notably for multi-contaminated soils. - Bioaugmentation-assisted plant improves the phytoextraction performances for soils contaminated by metals

  12. Performance of bioaugmentation-assisted phytoextraction applied to metal contaminated soils: A review

    Energy Technology Data Exchange (ETDEWEB)

    Lebeau, Thierry [Equipe Depollution Biologique des Sols (EDBS), University of Haute-Alsace, 28, rue de Herrlisheim, BP 50 568, 68 008 Colmar Cedex (France)], E-mail: thierry.lebeau@uha.fr; Braud, Armelle; Jezequel, Karine [Equipe Depollution Biologique des Sols (EDBS), University of Haute-Alsace, 28, rue de Herrlisheim, BP 50 568, 68 008 Colmar Cedex (France)

    2008-06-15

    Bioaugmentation-assisted phytoextraction is a promising method for the cleaning-up of soils contaminated by metals. Bacteria mainly Plant Growth Promoting Rhizobacteria (PGPR) and fungi mainly Arbuscular Mycorrhizal Fungi (AMF) associated with hyperaccumulating or non-hyperaccumulating plants were analyzed on the basis of a bioprocess engineering approach (concentration and amount of metals extracted by plants, translocation and bioconcentration factor, and plant biomass). In average bioaugmentation increased metals accumulated by shoots by a factor of about 2 (metal concentration) and 5 (amount) without any obvious differences between bacteria and fungi. To optimize this process, new relevant microorganism-plant associations and field scale experiments are needed along with a common methodology for the comparison of all experiments on the same basis. Recommendations were suggested concerning both the microbial-plant selection and the implementation of bioaugmentation to enhance the microbial survival. The use of microbial consortia associated with plant was discussed notably for multi-contaminated soils. - Bioaugmentation-assisted plant improves the phytoextraction performances for soils contaminated by metals.

  13. Performance comparison of digital microRNA profiling technologies applied on human breast cancer cell lines.

    Directory of Open Access Journals (Sweden)

    Erik Knutsen

    Full Text Available MicroRNA profiling represents an important first-step in deducting individual RNA-based regulatory function in a cell, tissue, or at a specific developmental stage. Currently there are several different platforms to choose from in order to make the initial miRNA profiles. In this study we investigate recently developed digital microRNA high-throughput technologies. Four different platforms were compared including next generation SOLiD ligation sequencing and Illumina HiSeq sequencing, hybridization-based NanoString nCounter, and miRCURY locked nucleic acid RT-qPCR. For all four technologies, full microRNA profiles were generated from human cell lines that represent noninvasive and invasive tumorigenic breast cancer. This study reports the correlation between platforms, as well as a more extensive analysis of the accuracy and sensitivity of data generated when using different platforms and important consideration when verifying results by the use of additional technologies. We found all the platforms to be highly capable for microRNA analysis. Furthermore, the two NGS platforms and RT-qPCR all have equally high sensitivity, and the fold change accuracy is independent of individual miRNA concentration for NGS and RT-qPCR. Based on these findings we propose new guidelines and considerations when performing microRNA profiling.

  14. Evaluation of icing drag coefficient correlations applied to iced propeller performance prediction

    Science.gov (United States)

    Miller, Thomas L.; Shaw, R. J.; Korkan, K. D.

    1987-01-01

    Evaluation of three empirical icing drag coefficient correlations is accomplished through application to a set of propeller icing data. The various correlations represent the best means currently available for relating drag rise to various flight and atmospheric conditions for both fixed-wing and rotating airfoils, and the work presented here ilustrates and evaluates one such application of the latter case. The origins of each of the correlations are discussed, and their apparent capabilities and limitations are summarized. These correlations have been made to be an integral part of a computer code, ICEPERF, which has been designed to calculate iced propeller performance. Comparison with experimental propeller icing data shows generally good agreement, with the quality of the predicted results seen to be directly related to the radial icing extent of each case. The code's capability to properly predict thrust coefficient, power coefficient, and propeller efficiency is shown to be strongly dependent on the choice of correlation selected, as well as upon proper specificatioon of radial icing extent.

  15. The performances of standard and ResMed masks during bag-valve-mask ventilation.

    Science.gov (United States)

    Lee, Hyoung Youn; Jeung, Kyung Woon; Lee, Byung Kook; Lee, Seung Joon; Jung, Yong Hun; Lee, Geo Sung; Min, Yong Il; Heo, Tag

    2013-01-01

    A tight mask seal is frequently difficult to obtain and maintain during single-rescuer bag-valve-mask (BVM) ventilation. The ResMed mask (Bella Vista, NSW, Australia) is a continuous-positive-airway-pressure mask (CM) designed for noninvasive ventilation. In this study, we compared the ventilation performances of a standard mask (SM) and a ResMed CM using a simulation manikin in an out-of-hospital single-rescuer BVM ventilation scenario. Thirty emergency medical technicians (EMTs) performed two 2-minute attempts to ventilate a simulation manikin using BVM ventilation, alternatively, with the SM or the ResMed CM in a randomized order. Ventilation parameters including tidal volume and peak airway pressure were measured using computer analysis software connected to the simulation manikin. Successful volume delivery was defined as delivery of 440-540 mL of tidal volume in accord with present cardiopulmonary resuscitation guidelines. BVM ventilation using the ResMed CM produced higher mean (± standard deviation) tidal volumes (452 ± 50 mL vs. 394 ± 113 mL, p = 0.014) and had a higher proportion of successful volume deliveries (65.3% vs. 26.7%, p < 0.001) than that using the SM. Peak airway pressure was higher in BVM ventilation using the ResMed CM (p = 0.035). Stomach insufflation did not occur during either method. Twenty-nine of the participants (96.7%) preferred BVM ventilation using the ResMed CM. BVM ventilations using ResMed CM resulted in a significantly higher proportion of successful volume deliveries meeting the currently recommended range of tidal volume. Clinical studies are needed to determine the value of the ResMed CM for BVM ventilation.

  16. Predictive performance for population models using stochastic differential equations applied on data from an oral glucose tolerance test

    DEFF Research Database (Denmark)

    Møller, Jonas Bech; Overgaard, R.V.; Madsen, Henrik

    2010-01-01

    Several articles have investigated stochastic differential equations (SDEs) in PK/PD models, but few have quantitatively investigated the benefits to predictive performance of models based on real data. Estimation of first phase insulin secretion which reflects beta-cell function using models of ...... obtained from the glucose tolerance tests. Since, the estimation time of extended models was not heavily increased compared to basic models, the applied method is concluded to have high relevance not only in theory but also in practice....

  17. Early detection of poor adherers to statins: applying individualized surveillance to pay for performance.

    Directory of Open Access Journals (Sweden)

    Andrew J Zimolzak

    Full Text Available Medication nonadherence costs $300 billion annually in the US. Medicare Advantage plans have a financial incentive to increase medication adherence among members because the Centers for Medicare and Medicaid Services (CMS now awards substantive bonus payments to such plans, based in part on population adherence to chronic medications. We sought to build an individualized surveillance model that detects early which beneficiaries will fall below the CMS adherence threshold.This was a retrospective study of over 210,000 beneficiaries initiating statins, in a database of private insurance claims, from 2008-2011. A logistic regression model was constructed to use statin adherence from initiation to day 90 to predict beneficiaries who would not meet the CMS measure of proportion of days covered 0.8 or above, from day 91 to 365. The model controlled for 15 additional characteristics. In a sensitivity analysis, we varied the number of days of adherence data used for prediction.Lower adherence in the first 90 days was the strongest predictor of one-year nonadherence, with an odds ratio of 25.0 (95% confidence interval 23.7-26.5 for poor adherence at one year. The model had an area under the receiver operating characteristic curve of 0.80. Sensitivity analysis revealed that predictions of comparable accuracy could be made only 40 days after statin initiation. When members with 30-day supplies for their first statin fill had predictions made at 40 days, and members with 90-day supplies for their first fill had predictions made at 100 days, poor adherence could be predicted with 86% positive predictive value.To preserve their Medicare Star ratings, plan managers should identify or develop effective programs to improve adherence. An individualized surveillance approach can be used to target members who would most benefit, recognizing the tradeoff between improved model performance over time and the advantage of earlier detection.

  18. Geographically weighted negative binomial regression applied to zonal level safety performance models.

    Science.gov (United States)

    Gomes, Marcos José Timbó Lima; Cunto, Flávio; da Silva, Alan Ricardo

    2017-09-01

    Generalized Linear Models (GLM) with negative binomial distribution for errors, have been widely used to estimate safety at the level of transportation planning. The limited ability of this technique to take spatial effects into account can be overcome through the use of local models from spatial regression techniques, such as Geographically Weighted Poisson Regression (GWPR). Although GWPR is a system that deals with spatial dependency and heterogeneity and has already been used in some road safety studies at the planning level, it fails to account for the possible overdispersion that can be found in the observations on road-traffic crashes. Two approaches were adopted for the Geographically Weighted Negative Binomial Regression (GWNBR) model to allow discrete data to be modeled in a non-stationary form and to take note of the overdispersion of the data: the first examines the constant overdispersion for all the traffic zones and the second includes the variable for each spatial unit. This research conducts a comparative analysis between non-spatial global crash prediction models and spatial local GWPR and GWNBR at the level of traffic zones in Fortaleza/Brazil. A geographic database of 126 traffic zones was compiled from the available data on exposure, network characteristics, socioeconomic factors and land use. The models were calibrated by using the frequency of injury crashes as a dependent variable and the results showed that GWPR and GWNBR achieved a better performance than GLM for the average residuals and likelihood as well as reducing the spatial autocorrelation of the residuals, and the GWNBR model was more able to capture the spatial heterogeneity of the crash frequency. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Broiler performance, hatching egg, and age relationships of progeny from standard and dwarf broiler dams.

    Science.gov (United States)

    Tahir, M; Cervantes, H; Farmer, C W; Shim, M Y; Pesti, G M

    2011-06-01

    The relationship of egg and chick weights to the performance of broiler chickens from two 42-wk-old flocks (standard and dwarf dams) having male parents from the same genetic stock was investigated in this study. Fertility (91.7 vs. 94.7%) and hatchability (95.2 vs. 96.3%) were not significantly (P > 0.10) different for eggs from standard and dwarf dams, respectively. Egg weight contributed significantly to the variation in BW [BW = β(0) + β(i) (egg weight) + β(i) (dam) + β(i) (sex)]. Body weight as a function of chick weight was not significant. However, chick weight was significant when included in a model with egg weight, suggesting that significant differences in BW at 50 d could be attributed to both egg and chick weights. The negative coefficient for chick weight indicated that between the 2 broilers of the same egg weight, the one with the greater chick weight would have the smaller 50-d BW. Chick weight was a linear function of egg weight. Similarly, the effect of egg or chick weight on broiler BW at 35 or 50 d was best represented by a single linear function. Dam genotype did not contribute significantly to variation in 50-d BW after variation attributable to egg weight was removed from the model. Differences in BW attributable to egg weight increased with broiler age. The coefficients of egg weight and chick weight showed that the differences in BW per gram of egg were 1.43, 3.06, 6.24, and 7.61 g and those per gram of chick were 1.87, 3.99, 8.14, and 9.93 g, respectively, at 7, 21, 35, and 50 d. Body weight increased by 0.1563 times egg weight (and 0.2092 times chick weight) with each additional day of age for both sexes and genotypes. Clearly, both egg and chick weights are important for modeling or predicting market-age broiler BW and economic returns. The relatively small relationship between BW and egg weight demonstrates that genetic selection over the past 3 decades has decreased the influence of egg weight on broiler growth. The present dwarf

  20. Performance Analysis of Video PHY Controller Using Unidirection and Bi-directional IO Standard via 7 Series FPGA

    DEFF Research Database (Denmark)

    Das, Bhagwan; Abdullah, M F L; Hussain, Dil muhammed Akbar

    2017-01-01

    graphics consumes more power, this creates a need of designing the low power design for Video PHY controller. In this paper, the performance of Video PHY controller is analyzed by comparing the power consumption of unidirectional and bi-directional IO Standard over 7 series FPGA. It is determined...... that total on-chip power is reduced for unidirectional IO Standard based Video PHY controller compared to bidirectional IO Standard based Video PHY controller. The most significant achievement of this work is that it is concluded that unidirectional IO Standard based Video PHY controller consume least...... standby power compared to bidirectional IO Standard based Video PHY controller. It is defined that for 6 GHz operated frequency Video PHY controller, the 32% total on-chip power is reduced using unidirectional IO Standard based Video PHY controller is less compared to bidirectional IO Standard based Video...

  1. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation

    International Nuclear Information System (INIS)

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This manual covers an array of modules written for the SCALE package, consisting of drivers, system libraries, cross section and materials properties libraries, input/output routines, storage modules, and help files

  2. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This manual covers an array of modules written for the SCALE package, consisting of drivers, system libraries, cross section and materials properties libraries, input/output routines, storage modules, and help files.

  3. Standard test methods for performance characteristics of metallic bonded resistance strain gages

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 The purpose of this standard is to provide uniform test methods for the determination of strain gauge performance characteristics. Suggested testing equipment designs are included. 1.2 Test Methods E 251 describes methods and procedures for determining five strain gauge parameters: Section Part I—General Requirements 7 Part II—Resistance at a Reference Temperature 8 Part III—Gauge Factor at a Reference Temperature 9 Part IV—Temperature Coefficient of Gauge Factor\t10 Part V—Transverse Sensitivity\t11 Part VI—Thermal Output\t12 1.3 Strain gauges are very sensitive devices with essentially infinite resolution. Their response to strain, however, is low and great care must be exercised in their use. The performance characteristics identified by these test methods must be known to an acceptable accuracy to obtain meaningful results in field applications. 1.3.1 Strain gauge resistance is used to balance instrumentation circuits and to provide a reference value for measurements since all data are...

  4. Analysis of free electron laser performance utilizing the National Bureau of Standards' CW microtron

    International Nuclear Information System (INIS)

    Tang, C.M.; Sprangle, P.; Penner, S.; Maruyama, X.K.

    1987-01-01

    The National Bureau of Standards' (NBS) CW racetrack microtron (RTM) will be utilized as a driver for a free electron laser (FEL) oscillator. The NBS RTM possesses many exceptional properties of value for the FEL: i) CW operation, ii) energy from 20-185 MeV, iii) small energy spread and emittance, iv) excellent energy stability, and v) high average power. The 1-D FEL gain formula predicts that the FEL would oscillate at the fundamental approximately from 0.25 μm to 10 μm when up-grading the peak current to ≥ 2 A. In this paper, the authors present 3-D self-consistent numerical results including several realistic effects, such as emittance, betatron oscillations, diffraction and refraction. The results indicate that the design value of the transverse emittance is small enough that it does not degrade the FEL performance for intermediate to long wavelengths, and only slightly degrades the performance at the shortest wavelength under consideration. Due to the good emittance, the current density is high enough that focusing, or guiding, begins to manifest itself for wavelengths > 2.0 μm

  5. Commercial and Industrial Solid Waste Incineration Units (CISWI): New Source Performance Standards (NSPS) and Emission Guidelines (EG) for Existing Sources

    Science.gov (United States)

    Learn about the New Source Performance Standards (NSPS) for commercial and industrial solid waste incineration (CISWI) units including emission guidelines and compliance times for the rule. Read the rule history and summary, and find supporting documents

  6. From 'Compliance-based' to 'Performance-based' Quality - A trend in and evolution of U. S. quality standards

    International Nuclear Information System (INIS)

    Brown, Douglas A.; Taylor, H. Stephen; Johnson, Robert B.; Erler, Bryan A.; Daley, Thomas J.

    1995-01-01

    This paper traces the evolution of quality systems for nuclear power plant design, procurement, fabrication, installation, pre-operational testing, operations and maintenance in the U. S., as reflected in consensus standards such as N45.2, NQA-1, etc. Using a 'Defense-In-Depth' Quality Model, it highlights the changes in understanding where the responsibilities for quality should reside. Industries' growing recognition and operating experience show that a 'graded' approach to quality, based on safety significance, can be used to determine which quality criteria apply and the depth of implementing those criteria, resulting in potential long term cost savings and increased effectiveness) is also examined and discussed. Together, these two approaches form the basis for a performance-based quality system suitable for the business and technical environment of the 1990's and beyond. Performance-based Quality System - an approach that focuses on the end results, not the process, that directly contribute to safe and reliable plant operations. This approach includes monitoring performance or condition against predetermined, licensee-established goals, limits, or criteria in a manner sufficient to provide reasonable assurance that the safety function will be fulfilled. These criteria are based upon the design basis safety function, operating experience, and pertinent reliability studies. A licensee is allowed the flexibility to determine how best to achieve the results and adjust the application of quality elements accordingly. The roles of the individual worker, site/line supervision and management, independent quality verifiers (QA and QC), and external regulators are examined in the context of where and how industry quality standards have historically placed emphasis and accountability. The changes in these standards and their of effects are illustrated. Based on industry experience, the current understanding of the controls necessary to achieve safe, reliable and

  7. Mercury-Cadmium-Telluride Focal Plane Array Performance Under Non-Standard Operating Conditions

    Science.gov (United States)

    Richardson, Brandon S.; Eastwood, Michael L.; Bruce, Carl F.; Green, Robert O.; Coles, J. B.

    2011-01-01

    This paper highlights a new technique that allows the Teledyne Scientific & Imaging LLC TCM6604A Mercury-Cadmium-Telluride (MCT) Focal Plane Array (FPA) to operate at room temperature. The Teledyne MCT FPA has been a standard in Imaging Spectroscopy since its creation in the 1980's. This FPA has been used in applications ranging from space instruments such as CRISM, M3 and ARTEMIS to airborne instruments such as MaRS and the Next Generation AVIRIS Instruments1. Precise focal plane alignment is always a challenge for such instruments. The current FPA alignment process results in multiple cold cycles requiring week-long durations, thereby increasing the risk and cost of a project. These alignment cycles are necessary because optimal alignment is approached incrementally and can only be measured with the FPA and Optics at standard operating conditions, requiring a cold instrument. Instruments using this FPA are normally cooled to temperatures below 150K for the MCT FPA to properly function. When the FPA is run at higher temperatures the dark current increases saturating the output. This paper covers the prospect of warm MCT FPA operation from a theoretical and experimental perspective. We discuss the empirical models and physical laws that govern MCT material properties and predict the optimal settings that will result in the best MCT PA performance at 300K. Theoretical results are then calculated for the proposed settings. We finally present the images and data obtained using the actual system with the warm MCT FPA settings. The paper concludes by emphasizing the strong positive correlation between the measured values and the theoretical results.

  8. Performance of the RAD-57 pulse CO-oximeter compared with standard laboratory carboxyhemoglobin measurement.

    Science.gov (United States)

    Touger, Michael; Birnbaum, Adrienne; Wang, Jessica; Chou, Katherine; Pearson, Darion; Bijur, Polly

    2010-10-01

    We assess agreement between carboxyhemoglobin levels measured by the Rad-57 signal extraction pulse CO-oximeter (RAD), a Food and Drug Administration-approved device for noninvasive bedside measurement, and standard laboratory arterial or venous measurement in a sample of emergency department (ED) patients with suspected carbon monoxide poisoning. The study was a cross-sectional cohort design using a convenience sample of adult and pediatric ED patients in a Level I trauma, burn, and hyperbaric oxygen referral center. Measurement of RAD carboxyhemoglobin was performed simultaneously with blood sampling for laboratory determination of carboxyhemoglobin level. The difference between the measures for each patient was calculated as laboratory carboxyhemoglobin minus carboxyhemoglobin from the carbon monoxide oximeter. The limits of agreement from a Bland-Altman analysis are calculated as the mean of the differences between methods ±1.96 SDs above and below the mean. Median laboratory percentage carboxyhemoglobin level was 2.3% (interquartile range 1 to 8.5; range 0% to 38%). The mean difference between laboratory carboxyhemoglobin values and RAD values was 1.4% carboxyhemoglobin (95% confidence interval [CI] 0.2% to 2.6%). The limits of agreement of differences of measurement made with the 2 devices were -11.6% and 14.4% carboxyhemoglobin. This range exceeded the value of ±5% carboxyhemoglobin defined a priori as clinically acceptable. RAD correctly identified 11 of 23 patients with laboratory values greater than 15% carboxyhemoglobin (sensitivity 48%; 95% CI 27% to 69%). There was one case of a laboratory carboxyhemoglobin level less than 15%, in which the RAD device gave a result greater than 15% (specificity of RAD 96/97=99%; 95% CI 94% to 100%). In the range of carboxyhemoglobin values measured in this sample, the level of agreement observed suggests RAD measurement may not be used interchangeably with standard laboratory measurement. Copyright © 2010 American

  9. Standards should be applied in the prevention and handling of missing data for patient-centered outcomes research: a systematic review and expert consensus.

    Science.gov (United States)

    Li, Tianjing; Hutfless, Susan; Scharfstein, Daniel O; Daniels, Michael J; Hogan, Joseph W; Little, Roderick J A; Roy, Jason A; Law, Andrew H; Dickersin, Kay

    2014-01-01

    To recommend methodological standards in the prevention and handling of missing data for primary patient-centered outcomes research (PCOR). We searched National Library of Medicine Bookshelf and Catalog as well as regulatory agencies' and organizations' Web sites in January 2012 for guidance documents that had formal recommendations regarding missing data. We extracted the characteristics of included guidance documents and recommendations. Using a two-round modified Delphi survey, a multidisciplinary panel proposed mandatory standards on the prevention and handling of missing data for PCOR. We identified 1,790 records and assessed 30 as having relevant recommendations. We proposed 10 standards as mandatory, covering three domains. First, the single best approach is to prospectively prevent missing data occurrence. Second, use of valid statistical methods that properly reflect multiple sources of uncertainty is critical when analyzing missing data. Third, transparent and thorough reporting of missing data allows readers to judge the validity of the findings. We urge researchers to adopt rigorous methodology and promote good science by applying best practices to the prevention and handling of missing data. Developing guidance on the prevention and handling of missing data for observational studies and studies that use existing records is a priority for future research. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Academy of Nutrition and Dietetics: Standards of professional performance for Registered Dietitian Nutritionists (Competent, Proficient, and Expert) in Sustainable, Resilient, and Healthy Food and Water Systems.

    Science.gov (United States)

    Tagtow, Angie; Robien, Kim; Bergquist, Erin; Bruening, Meg; Dierks, Lisa; Hartman, Barbara E; Robinson-O'Brien, Ramona; Steinitz, Tamara; Tahsin, Bettina; Underwood, Teri; Wilkins, Jennifer

    2014-03-01

    Sustainability is the ability of a system to be maintained over the long term. Resilience is the ability of a system to withstand disturbances and continue to function in a sustainable manner. Issues of sustainability and resilience apply to all aspects of nutrition and dietetics practice, can be practiced at both the program and systems level, and are broader than any one specific practice setting or individual intervention. Given an increasing need to apply principles of sustainability and resilience to nutrition and dietetics practice, as well as growing interest among the public and by Registered Dietitian Nutritionists of health issues related to food and water systems, the Hunger and Environmental Nutrition Dietetic Practice Group, with guidance from the Academy of Nutrition and Dietetics Quality Management Committee, has developed the Standards of Professional Performance as a tool for Registered Dietitian Nutritionists working in sustainable, resilient, and healthy food and water systems to assess their current skill levels and to identify areas for further professional development in this emerging practice area. This Standards of Professional Performance document covers six standards of professional performance: quality in practice, competence and accountability, provision of services, application of research, communication and application of knowledge, and utilization and management of resources. Within each standard, specific indicators provide measurable action statements that illustrate how sustainable, resilient, and healthy food and water systems principles can be applied to practice. The indicators describe three skill levels (competent, proficient, and expert) for Registered Dietitian Nutritionists working in sustainable, resilient, and healthy food and water systems. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  11. Collectivism versus individualism: performance-related pay and union coverage for non-standard workers in Britain

    OpenAIRE

    Booth, Alison L.; Francesconi, Marco

    2000-01-01

    This paper documents the extent of union coverage and performance-related pay (PRP) - the latter representing one aspect of pay flexibility - across standard and non-standard workers in Britain, using the first seven waves of the British Household Panel Survey, 1991-1997. We find there is no evidence of expansion of either union coverage or PRP towards any type of non-standard employment in the 1990s. Thus union rhetoric about a 'strategy of enlargement' towards non-standard workers remains j...

  12. Analysis of Minimum Efficiency Performance Standards for Residential General Service Lighting in Chile

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie E.; McNeil, Michael A.; Leiva Ibanez, Francisco Humberto; Ruiz, Ana Maria; Pavon, Mariana; Hall, Stephen

    2011-06-01

    Minimum Efficiency Performance Standards (MEPS) have been chosen as part of Chile's national energy efficiency action plan. As a first MEPS, the Ministry of Energy has decided to focus on a regulation for lighting that would ban the sale of inefficient bulbs, effectively phasing out the use of incandescent lamps. Following major economies such as the US (EISA, 2007) , the EU (Ecodesign, 2009) and Australia (AS/NZS, 2008) who planned a phase out based on minimum efficacy requirements, the Ministry of Energy has undertaken the impact analysis of a MEPS on the residential lighting sector. Fundacion Chile (FC) and Lawrence Berkeley National Laboratory (LBNL) collaborated with the Ministry of Energy and the National Energy Efficiency Program (Programa Pais de Eficiencia Energetica, or PPEE) in order to produce a techno-economic analysis of this future policy measure. LBNL has developed for CLASP (CLASP, 2007) a spreadsheet tool called the Policy Analysis Modeling System (PAMS) that allows for evaluation of costs and benefits at the consumer level but also a wide range of impacts at the national level, such as energy savings, net present value of savings, greenhouse gas (CO2) emission reductions and avoided capacity generation due to a specific policy. Because historically Chile has followed European schemes in energy efficiency programs (test procedures, labelling program definitions), we take the Ecodesign commission regulation No 244/2009 as a starting point when defining our phase out program, which means a tiered phase out based on minimum efficacy per lumen category. The following data were collected in order to perform the techno-economic analysis: (1) Retail prices, efficiency and wattage category in the current market, (2) Usage data (hours of lamp use per day), and (3) Stock data, penetration of efficient lamps in the market. Using these data, PAMS calculates the costs and benefits of efficiency standards from two distinct but related perspectives: (1) The

  13. Performance, compliance and reliability of Waste stabilization pond: Effluent discharge quality and environmental protection agency standards in Ghana

    DEFF Research Database (Denmark)

    Owusu-Ansah, Emmanuel de-Graft Johnson; Sampson, Angelina; Amponsah, Samuel K.

    2015-01-01

    function to establish the relationship between the statistical coefficient of variation and the coefficient of reliability based on rth moment about the origin in the moment of generation function to generate the functions of the mean and standard deviation, properties of the standard Z normal distribution...... were used to establish the coefficient of reliability relationship depending on the coefficient of variation influenced by the standard of deviation. Discharge values of Physico-chemical Parameters measured from the WSP were found be performing acceptably based on the EPA standards, whereas only four......Measuring performance has been arguerably, one of the metric with many facets with different school of thoughts, as there exist different approaches of measuring it. Several of the existing approaches measure such metric by comparison with standards esherined in policy documents and as a result...

  14. The radiation performance standard (SPN) in the Netherlands; De stralingsprestatienorm (SPN) nader toegelicht

    Energy Technology Data Exchange (ETDEWEB)

    Van Aernsbergen, L.M.; Klomberg, T.; Van Luijk, P. [Ministerie van VROM, Den Haag (Netherlands)

    2002-07-01

    The radiation performance standard (SPN, abbreviated in Dutch) is a measure for the maximum level of radiation in newly built houses (radon and external radiation). A brief overview is given of the principle of the SPN, the planned legal implementation as part of the Dutch Building Decree ('Bouwbesluit'), and the calculation method (NEN 1781) [Dutch] Vanaf 1 januari 2003 wordt het stralingsniveau in nieuwbouwwoningen aan een maximum gebonden. Het gaat daarbij om de totale dosis door radon en externe straling. Vergeleken met het buitenland is het stralingsniveau in de woning laag in ons land. Desalniettemin loopt de gemiddelde Nederlander de helft van de totale stralingsdosis binnenshuis op. Volgens de Gezondheidsraad leidt blootstelling aan radon binnenshuis in Nederland tot naar schatting tussen 100 en 1200 extra gevallen van longkanker (centrale schatting is 800). Verder blijkt uit onderzoek dat in Nederlandse nieuwbouwwoningen de gemiddelde radonconcentratie in de twee decennia na 1970 met circa 50% is toegenomen. De Nederlandse overheid vindt een gezond binnenklimaat belangrijk, daarom is een zogenaamde Stralings Prestatie Norm (SPN) ontwikkeld. Het beleid is om te vermijden dat de straling in de woning verder toeneemt. De SPN richt zich op nog te bouwen woningen.

  15. The Impact of Minimum Energy Performance Standards (MEPS) Regulation on Electricity Saving in Malaysia

    Science.gov (United States)

    Fatihah Salleh, Siti; Eqwan Roslan, Mohd; Isa, Aishah Mohd; Faizal Basri Nair, Mohd; Syafiqah Salleh, Siti

    2018-03-01

    One of Malaysia’s key strategies to promote efficient energy use in the country is to implement the minimum energy performance standards (MEPS) through the Electricity Regulations (Amendment) 2013. Five selected electrical appliances (refrigerator, air conditioner, television, domestic fans and lamp fittings) must comply with MEPS requirement in order to be sold in Malaysian market. Manufacturers, importers or distributors are issued Certificate of Approval (COA) if products are MEPS-compliant. In 2015, 1,215 COAs were issued but the number of MEPS products in the market is unknown. This work collects sales data from major manufacturers to estimate the annual sales of MEPS appliances and the cumulative electricity consumption and electricity saving. It was found that most products sold have 3-star rating and above. By year 2015, total cumulative electricity savings gained from MEPS implementation is 3,645 GWh, with air conditioner being the highest contributor (30%). In the future, it is recommended that more MEPS products and related incentives be introduced to further improve efficiency of energy use in Malaysia.

  16. Inquiry-based laboratory investigations and student performance on standardized tests in biological science

    Science.gov (United States)

    Patke, Usha

    Achievement data from the 3rd International Mathematics and Sciences Study and Program for International Student Assessment in science have indicated that Black students from economically disadvantaged families underachieve at alarming rates in comparison to White and economically advantaged peer groups. The study site was a predominately Black, urban school district experiencing underachievement. The purpose of this correlational study was to examine the relationship between students' use of inquiry-based laboratory investigations and their performance on the Biology End of Course Test, as well as to examine the relationship while partialling out the effects of student gender. Constructivist theory formed the theoretical foundation of the study. Students' perceived levels of experience with inquiry-based laboratory investigations were measured using the Laboratory Program Variable Inventory (LPVI) survey. LPVI scores of 256 students were correlated with test scores and were examined by student gender. The Pearson correlation coefficient revealed a small direct correlation between students' experience in inquiry-based laboratory investigation classes and standardized test scores on the Biology EOCT. A partial correlational analysis indicated that the correlation remained after controlling for gender. This study may prompt a change from teacher-centered to student-centered pedagogy at the local site in order to increase academic achievement for all students. The results of this study may also influence administrators and policy makers to initiate local, state, or nationwide curricular development. A change in curriculum may promote social change as students become more competent, and more able, to succeed in life beyond secondary school.

  17. Energy Efficiency: The Implementation of Minimum Energy Performance Standard (MEPS Application on Home Appliances for Residential

    Directory of Open Access Journals (Sweden)

    Rahman K.A

    2016-01-01

    Full Text Available Generally, Minimum Energy Performance Standard (MEPS has been widespread across the country especially developed country. However, most consumers do not even know about the MEPS. Without sufficient knowledge, much energy have been wasted before this. The aim of this study is to review the implementation of MEPS of Asia country and to compare electricity consumption of home appliances with star rating and without star rating. In order to fulfil the objectives of the study, the equipment must be chosen correctly and must be learned properly. The home appliances that will be used also need to be chosen so that the comparison between the appliances will be matched correctly. To understand the results, the analysis was done using graphs and table. The purpose of using graph and table is to understand the comparison between appliances more clearly. The results show that home appliances with MEPS is more efficient on energy saving rather than without MEPS. This is the evidence as a method to educate a consumer on energy saving.

  18. The performance of a surface-applied corrosion inhibitor for the carbon steel in saturated Ca(OH)2 solutions

    International Nuclear Information System (INIS)

    Zheng, Haibing; Li, Weihua; Ma, Fubin; Kong, Qinglin

    2014-01-01

    In the present work, the performance of an amino alcohol based surface applied inhibitor was studied by the electrochemical techniques in saturated Ca(OH) 2 solutions. The surface morphology of the carbon steel was observed by scanning electron microscope, and the energy diffraction spectrum was also tested. Results showed that the inhibitor used in this work demonstrated obvious inhibition efficiency on the carbon steel in saturated Ca(OH) 2 solutions. The inhibition mechanism of the inhibitor lies in the quick adsorption of the active component on carbon steel surface

  19. Marker based standardization of polyherbal formulation (SJT-DI-02 by high performance thin layer chromatography method

    Directory of Open Access Journals (Sweden)

    Bhakti J Ladva

    2014-01-01

    Full Text Available Background: Preparation of highly standardized herbal products with respect to chemical composition and biological activity is considered to be a valuable approach in this field. SJT-DI-02 polyherbal formulation was successfully developed at our institute and filed for patent at Mumbai patent office. Objective: The present work was marker based standardization of patented, novel and efficacious polyherbal formulation namely SJT-DI-02 for the treatment of diabetes. The SJT-DI-02 was comprised of dried extracts of rhizomes of Acorus calamus, leaves of Aegle marmelose, fruits of Benincasa hispida, roots of Chlorophytum arendinaceum, seeds of Eugenia jambolana, leaves of Ocimum sanctum, pericarp of Punica granatum, seeds of Tamarindus indica. Selected plants were collected, dried and extracted with suitable solvents. The formulation was prepared by mixing different fractions of extracts. Materials and Methods: For successful and best standardization, first of all selection and procurement was carried out. Selection is done on the basis of therapeutic efficacy and amount of the marker present in the particular plant part. At the time of procurement side by side phytochemical screening and estimation of phytoconstituents was carried out. After completion of preliminary screening using characterized markers, we tried to develop best TLC systems using selected solvent composition. Finally well-developed TLC systems were applied in HPTLC. In the present study polyherbal formulation was standardized by using different four markers. TLC Densitometric methods were developed using HPTLC for the quantification of these marker compounds. Solvent systems were optimized to achieve best resolution of the marker compounds from other components of the sample extract. The identity of the bands in the sample extracts were confirmed by comparing the Rf and the absorption spectra by overlaying their UV absorption spectra with those of their respective standards. The

  20. Adjustable ETHD lubrication applied to the improvement of dynamic performance of flexible rotors supported by active TPJB

    DEFF Research Database (Denmark)

    Salazar, Jorge Andrés González; Cerda Varela, Alejandro Javier; Santos, Ilmar

    2013-01-01

    This paper reports the dynamic study of a flexible rotor-bearing test rig which resembles a large overhung centrifugal compressor. The rotor is supported by an active tilting pad journal bearing (TPJB) able to perform the adjustable lubrication regime. Such a regime is obtained by injecting...... pressurized oil directly into the bearing clearance through a nozzle placed in a radial bore at the middle of the pad and connected to a high pressure supply unit by servovalves. The theoretical model is based on a finite element model, where the active TPJB with adjustable lubrication is included using...... and the experimental results are obtained. The improvements are obtained when the system response amplitudes in a bounded speed range is reduced by applying the adjustable lubrication. Results are in agreement with the established fact that a significant improvement of the rotor-bearing system dynamic performance can...