Introduction to radiological performance assessment
International Nuclear Information System (INIS)
Moss, G.
1995-02-01
A radiological performance assessment is conducted to provide reasonable assurance that performance objectives for low-level radioactive waste (LLW) disposal will be met. Beginning in the early stages of development, a radiological performance assessment continues through the operational phase, and is instrumental in the postclosure of the facility. Fundamental differences exist in the regulation of commercial and defense LLW, but the radiological performance assessment process is essentially the same for both. The purpose of this document is to describe that process in a concise and straightforward manner. This document focuses on radiological performance assessment as it pertains to commercial LLW disposal, but is applicable to US Department of Energy sites as well. Included are discussions on performance objectives, site characterization, and how a performance assessment is conducted. A case study is used to illustrate how the process works as a whole. A bibliography is provided to assist in locating additional information
Radiological environmental impacts from transportation of nuclear materials
International Nuclear Information System (INIS)
Shuai Zhengqing
1994-01-01
The author describes radiological impacts from transportation of nuclear materials. RADTRAN 4.0 supplied by IAEA was adopted to evaluate radiological consequence of incident-free transportation as well as the radiological risks from vehicular accidents occurring during transportation. The results of calculation show that the collective effective dose equivalent of incident-free transportation to the public and transportation workers is 7.94 x 10 -4 man·Sv. The calculated data suggest that the environmental impacts under normal and assumed accidental conditions are acceptable
International Nuclear Information System (INIS)
Aitken, S.B.
1995-07-01
The INEL Radiological Control Performance Indicator Report is provided quarterly, inaccordance with Article 133 of the INEL Radiological Control Manual. Indicators are used as a measure of performance of the Radiological Control Program and as a motivation for improvement, not as a goal in themselves. These indicators should be used by management to assist in focusing priorities and attention and adherence to As-Low-As-Reasonably-Achievable (ALARA) practices. The ALARA Committees establish ALARA goals for the INEL based on forecasts and goals provided by each facility organizational manager or supervisor.Performance goals are realistic and measurable. Stringent goals are set at least annually to reflect expected workloads and improvement of radiological performance. Goals higher than previous goals may occasionally be set due to changes in work scope or mission. The INEL Radiological Control Performance Indicators consist of: Collective dose in person-rem; average worker dose, maximum dose to a worker, and maximum neutron dose to a worker;the number of skin and clothing contaminations, including the number of contaminated wounds and facial contaminations; the number of radioactive material intakes; the area of Contamination, High Contamination, and Airborne Radioactivity Areas in square feet; and airborne radioactivity events and spills
Development of radiological performance indicators for nuclear power plants
International Nuclear Information System (INIS)
Lee, B.S.; Jung, K.H.; Lee, S.H.; Jang, S.Y.
2000-01-01
The purpose of this work was to improve the regulatory approach to check the licensee's compliance with regulation regarding radiation protection in operating nuclear power plants (NPPs). The current domestic inspection program for NPPs requires inspectors to conduct compliance-inspection for the systems/equipment and the procedures of NPPs. In this work, we have developed a set of draft radiological performance indicators (PIs) to assess radiation safety in NPPs. The development of PIs was based on the concept that the licensees' implementation of the radiation protection program in NPPs should be able to achieve the goal of radiation protection which the International Commission on Radiological Protection (ICRP) has recommended as ICRP 60 (1991). We selected and/or developed the radiological performance indicators considering the radiation exposure network (source-environment-receptor) for NPPs. The PIs intend to be applied only to normal exposure due to normal operations including transient operational conditions, but not to potential exposure due to accidents. Also, we have chosen the receptor as workers who are occupationally exposed to radiation as well as the members of public who are exposed to radiation from radioactive effluents. The PIs intend to track the past performance rather than to expect the future performance. Finally, the individual PIs do not verify the root cause of the trend of performance; however, they provide the basis for deciding whether the procedures and work management have been properly implemented. Currently a set of 21 draft PIs has been developed for the exposure network in NPPs. For the receptor, the PIs are divided into worker individual dose, worker collective dose and public individual dose. For the environment, the PIs are related to the dose rates of controlled areas, radioactive material concentrations in controlled areas, radioactive contamination in controlled areas and at exit points, and radioactive effluent
International Nuclear Information System (INIS)
Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.
1985-01-01
A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)
Assessment of the radiological impact of the transport of radioactive materials
International Nuclear Information System (INIS)
1986-12-01
In order to facilitate the assessment of the radiological impact of transport, and to guide the collection of data for future assessments, the IAEA convened a technical committee (The Technical Committee on the Assessment of the Radiological Impact from the Transport of Radioactive Materials; TC-556) in Vienna, Austria on 21-25 October 1985. The Terms of Reference called for this committee ''to collect and assess data on the radiation exposure of workers and the public during the transport of radioactive material, and to develop a summary statement, reflecting current practice and current state of knowledge, on the radiological impact of transport.'' This technical document provides the summary statement developed by TC-556. The statement should be viewed as an interim assessment since it utilized only data then available, or made available, to the committee. This document consists of three Sections: Section I - Background Information to the Summary Statement (prepared by the Secretariat); Section II - The Summary Statement on the Radiological Impact of the Transport of Radioactive Materials (developed by TC-556); and Section III - Recommendations for Future Assessments (a summary of statements and conclusions provided in the TC-556 Chairman's Report)
Radiological assessment of an area with uranium residual material
International Nuclear Information System (INIS)
Perez-Sanchez, Danyl; Cancio, David; Alvarez, Alicia
2008-01-01
As a result of a pilot project developed at the old Spanish 'Junta de Energia Nuclear' to extract uranium from ores, tailings materials were generated. Most of these residual materials were sent back to different uranium mines, but a small amount of it was mixed with conventional building materials and deposited near the old plant until the surrounding ground was flattened. The affected land is included in an area under institutional control and used as recreational area. At the time of processing, uranium isotopes were separated but other radionuclides of the uranium decays series as 230 Th, 226 Ra and daughters remain in the residue. Recently, the analyses of samples taken at different ground's depths confirm their presence. This paper presents the methodology used to calculate the derived concentration level to ensure the reference dose level of 0.1 mSv y-1 used as radiological criteria. In this study, a radiological impact assessment was performed modelling the area as recreational scenario. The modelization study was carried out with the code RESRAD considering as exposure pathways, external irradiation, inadvertent ingestion of soil, inhalation of resuspended particles, and inhalation of outdoor radon ( 222 Rn). As result was concluded that, if the concentration of 226 Ra in the first 15 cm of soil is lower than, 0.34 Bq g-1 , the dose would not exceed the reference dose. Applying this value as a derived concentration level and comparing with the results of measurements on the ground, some areas with a concentration of activity slightly higher than latter were found. In these zones the remediation proposal has been to cover with a layer of 15 cm of clean material. This action represents a reduction of 85% of the dose and ensures compliance with the reference dose. (author)
Methodology for performing measurements to release material from radiological control
International Nuclear Information System (INIS)
Durham, J.S.; Gardner, D.L.
1993-09-01
This report describes the existing and proposed methodologies for performing measurements of contamination prior to releasing material for uncontrolled use at the Hanford Site. The technical basis for the proposed methodology, a modification to the existing contamination survey protocol, is also described. The modified methodology, which includes a large-area swipe followed by a statistical survey, can be used to survey material that is unlikely to be contaminated for release to controlled and uncontrolled areas. The material evaluation procedure that is used to determine the likelihood of contamination is also described
The Spanish Protocol for Collaboration on the Radiological Surveillance of Metallic Materials
Energy Technology Data Exchange (ETDEWEB)
Redondo, J.M., E-mail: jmredondo@mityc.es [Ministry of Industry, Tourism and Trade (Spain)
2011-07-15
In recent years the presence of radioactive material in scrap metal has been detected relatively often. This can cause the contamination of people or of the environment, as well as of the industrial facilities and of the product. The Spanish iron and steel industry is one of the most important industrial sectors in the country, and depends to a large extent on the importation of a significant proportion of the scrap used as raw material. Experience has shown that countries that import large quantities of scrap for their industries are more exposed to the existence of orphan radioactive sources and therefore, they have to adopt measures to reduce the risks arising from their presence. In 1999, the Spanish authorities, along with the business associations involved in the metal recovery and smelting industry, and the radioactive waste management agency, established a national system for the radiological surveillance and control of scrap metal and the products resulting from its processing. Since then, the most relevant trade unions and others in the industrial sector have also joined the system. It is based on the existence of a legal framework and on a set of voluntary commitments taken on by the involved parties. It is known as the Protocol for Collaboration for the Radiological Surveillance of Metallic Materials and is implemented by the installation of specific radiological surveillance equipment, the development of radiological training and information plans for the staff involved in the metal recovery and smelting sectors, the definition of a fully operational system to safely manage the materials detected, and a general improvement of the national radiological emergency system. (author)
Radiological consequences of radioactive substances in building materials
International Nuclear Information System (INIS)
Tschurlovits, M.
1982-01-01
A review of radiological consequences of radioactive substances in building materials is given. Where the other contributing papers are dealing with technical problems and measuring techniques, this paper is going beyond the term dose and is considering the risk by radioactive substances in building materials in relation to conventional risks. The present state of international standards is also discussed. If a limit of 1 mSv is adopted, it is shown that this limit is just met at present conditions. (Author) [de
International Nuclear Information System (INIS)
Drake, J.
2009-01-01
Immediate action would be necessary to minimize the effects of a radiological 'dirty bomb' detonation in a major city. After a dirty bomb has been detonated, vehicular and pedestrian traffic, as well as weather effects, would increase the spread of loose contamination, making control and recovery more difficult and costly. While contaminant migration and chemical binding into surface materials can be relatively rapid, the immediate treatment of surfaces with large quantities of an appropriate compound could alleviate much of the difficulty in decontamination. The EPA's National Homeland Security Research Center (NHSRC), in collaboration with ASTM International, is currently developing performance standards for materials which could be applied to exterior surfaces contaminated by an RDD to mitigate the spread and migration of radioactive contamination. These performance standards are being promulgated via an ASTM Standard Specification to be published by ASTM International. Test methods will be developed to determine if candidate coatings meet the performance requirements stipulated in the ASTM performance standard. These test methods will be adapted from existing standard methods, or will be devised through laboratory research. The final set of test methods will be codified in an ASTM or other standard test method. The principal market for products described in the ASTM performance standard would be federal, state and local government emergency responders and response planners, decontamination service providers and those whose interests include protection and recovery of real estate potentially at risk from radiological terrorism. (authors)
General Employee Radiological Training and Radiological Worker Training: Program management manual
International Nuclear Information System (INIS)
1992-10-01
This manual defines and describes the DOE General Employee Radiological Training (GERT) and Radiological Worker I and II (RW I and II) Training programs. It includes material development requirements, standards and policies, and program administration. This manual applies to General Employee Radiological Training and Radiological Worker Training at all DOE contractor sites. The training materials of both GERT and RW I and II training reflect the requirements identified in the DOE Radiological Control Manual and DOE Order 5480.11. The training programs represent the minimum requirement for the standardized core materials. Each contractor shall implement the program in its entirety and may augment the standardized core materials to increase the general employee and radiological worker level of competency
Radioactive Waste Management Complex low-level waste radiological performance assessment
Energy Technology Data Exchange (ETDEWEB)
Maheras, S.J.; Rood, A.S.; Magnuson, S.O.; Sussman, M.E.; Bhatt, R.N.
1994-04-01
This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsite receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected.
Radioactive Waste Management Complex low-level waste radiological performance assessment
International Nuclear Information System (INIS)
Maheras, S.J.; Rood, A.S.; Magnuson, S.O.; Sussman, M.E.; Bhatt, R.N.
1994-04-01
This report documents the projected radiological dose impacts associated with the disposal of radioactive low-level waste at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. This radiological performance assessment was conducted to evaluate compliance with applicable radiological criteria of the US Department of Energy and the US Environmental Protection Agency for protection of the public and the environment. The calculations involved modeling the transport of radionuclides from buried waste, to surface soil and subsurface media, and eventually to members of the public via air, groundwater, and food chain pathways. Projections of doses were made for both offsite receptors and individuals inadvertently intruding onto the site after closure. In addition, uncertainty and sensitivity analyses were performed. The results of the analyses indicate compliance with established radiological criteria and provide reasonable assurance that public health and safety will be protected
International Nuclear Information System (INIS)
Amran AB Majid; Aznan Fazli Ismail; Muhamad Samudi Yasir; Redzuwan Yahaya; Ismail Bahari
2013-01-01
Previous studies have shown that the natural radioactivity contained in building materials have significantly influenced the dose rates in dwelling. Exposure to natural radiation in building has been of concerned since almost 80 % of our daily live are spend indoor. Thus, the aim of the study is to assess the radiological risk associated by natural radioactivity in soil based building materials to dwellers. A total of 13 Portland cement, 46 sand and 43 gravel samples obtained from manufacturers or bought directly from local hardware stores in Peninsular of Malaysia were analysed for their radioactivity concentrations. The activity concentrations of 226 Ra, 232 Th and 40 K in the studied building materials samples were found to be in the range of 3.7-359.3, 2.0-370.8 and 10.3-1,949.5 Bq kg -1 respectively. The annual radiation dose rates (μSv year -1 ) received by dwellers were evaluated for 1 to 50 years of exposure using Resrad-Build Computer Code based on the activity concentration of 226 Ra, 232 Th and 40 K found in the studied building material samples. The rooms modelling were based on the changing parameters of concrete wall thickness and the room dimensions. The annual radiation dose rates to dwellers were found to increase annually over a period of 50 years. The concrete thicknesses were found to have significantly influenced the dose rates in building. The self-absorption occurred when the concrete thickness was thicker than 0.4 m. Results of this study shows that the dose rates received by the dwellers of the building are proportional to the size of the room. In general the study concludes that concrete building materials; Portland cements, sands, and gravels in Peninsular of Malaysia does not pose radiological hazard to the building dwellers. (author)
Medical Preparedness and Response for a Nuclear or Radiological Emergency. Training Materials
International Nuclear Information System (INIS)
2014-01-01
In almost all nuclear and radiological emergencies, local emergency services (e.g. local medical, law enforcement, and fire brigades) will have the most important role in the early response. Within hours, hospitals may also have an important role to play in the response at the local level. Since nuclear and radiological emergencies are rare, medical responders often have little or no experience in dealing with this type of emergency and inexperience may lead to an inadequate response. For this reason, training in medical preparedness and response for a nuclear or radiological emergency is an important aspect of preparedness and response activities. These materials are designed for use at a training course on medical preparedness and response for a nuclear or radiological emergency. They contain a wide range of lectures and supporting materials, which cover the basic topics and more specific areas of medical preparedness and response. Therefore, in planning their specific courses, organizers are encouraged to choose those lectures and supportive materials from the CD-ROM that best match their training priorities. Materials on the CD-ROM address the following areas: • Terrorism in Perspective; • Malicious Act Scenarios; • Providing Information to the Medical Community and the Public; • Medical Response to a Radiation Mass Casualty Event; • Handling of Contaminated Persons in Malicious Events; • Planning and Preparedness for Medical Response to Malicious Events with Radioactive Material; • Handling the Bodies of Decedents Contaminated with Radioactive Material; • Radiation Emergencies: Scope of the Problem; • Common Sources of Radiation; • Basic Concepts of Ionizing Radiation; • Basic Concepts of Radiation Protection; • Biological Effects of Ionizing Radiation – Basic Notions; • Basics of Radiopathology; • External Radioactive Contamination; • Internal Radioactive Contamination; • Acute Radiation Syndrome; • Cutaneous Radiation
American Society for Testing and Materials. Philadelphia
2009-01-01
1.1 This practice is intended to be used as a supplement to Practices E 1742, E 1255, and E 2033. 1.2 This practice describes procedures for radiologic examination of flat panel composites and sandwich core materials made entirely or in part from fiber-reinforced polymer matrix composites. Radiologic examination is: a) radiographic (RT) with film, b) Computed Radiography (CR) with Imaging Plate, c) Digital Radiology (DR) with Digital Detector Array’s (DDA), and d) Radioscopic (RTR) Real Time Radiology with a detection system such as an Image Intensifier. The composite materials under consideration typically contain continuous high modulus fibers (> 20 GPa), such as those listed in 1.4. 1.3 This practice describes established radiological examination methods that are currently used by industry that have demonstrated utility in quality assurance of flat panel composites and sandwich core materials during product process design and optimization, process control, after manufacture inspection, in service exami...
International Nuclear Information System (INIS)
Feng Guangwen; Hu Youhua; Liu Qian
2010-01-01
In this paper, the principle of TOPSIS method was introduced and applied to sorting the given indexes of glazed brick and granite respectively in different areas' decorative building materials in order to selecting the optimal low radiological decorative building materials. First, the entropy weight TOPSIS method was used for data processing about the sample numbers and radio nuclides content, and then different weights were given to different indexes. Finally, by using the SAS software for data analysis and sorting, we obtained that the optimal low radiological decorative building materials were Sichuan glazed brick and Henan granite. Through the results, it could be seen that the application of entropy weight TOPSIS method in selecting low radiological decorative building materials was feasible, and it will also provide the method reference. (authors)
A consequence index approach to identifying radiological sabotage targets
International Nuclear Information System (INIS)
Altman, W.D.; Hockert, J.W.
1988-01-01
One of the threats to concern to facilities using significant quantities of radioactive material is radiological sabotage. Both the Department of Energy (DOE) and the U.S. Nuclear Regulatory Commission have issued guidance to facilities for radiological sabotage protection. At those facilities where the inventories of radioactive materials change frequently, there is an operational need for a technically defensible method of determining whether or not the inventory of radioactive material at a given facility poses a potential radiological sabotage risk. In order to determine quickly whether a building is a potential radiological sabotage target, Lawrence Livermore National Loaboratory (LLNL) has developed a radiological sabotage consequence index that provides a conservative estimate of the maximum potential off-site consequences of a radiological sabotage attempt involving the facility. This radiological sabotage consequence index can be used by safeguards and security staff to rapidly determine whether a change in building operations poses a potential radiological sabotage risk. In those cases where such a potential risk is identified, a more detailed radiological sabotage vulnerability analysis can be performed
[Controlling instruments in radiology].
Maurer, M
2013-10-01
Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.
Study of the performance of diagnostic radiology instruments during calibration
International Nuclear Information System (INIS)
Freitas, Rodrigo N. de; Vivolo, Vitor; Potiens, Maria da Penha A.
2008-01-01
Full text: The instruments used in diagnostic radiology measurements represent 8 % of the tested instruments by the calibration laboratory of IPEN annually (approximately 1600 in 2007). Considering that the calibration of this kind of instrument is performed biannually it is possible to conclude that almost 300 instruments are being used to measure the air kerma in diagnostic radiology clinics to determine the in beam values (in front of the patient), attenuated measurements (behind the patient) and scattered radiation. This work presents the results of the calibration of the instruments used in mammography, computed tomography, dental and conventional diagnostic radiology dosimetry, performed during the period of 2005 to 2007. Their performances during the calibrations measurements were evaluated. Although at the calibration laboratory there are three available series of radiation quality to this type of calibration (RQR, N and M, according to standards IEC 61267 and ISO 4037-1.), the applications can be assorted (general radiology, computed tomography, mammography, radiation protection and fluoroscopy). Depending on its design and behaviour , one kind of instrument can be used for one or more type of applications. The instruments normally used for diagnostic radiology measurements are ionization chambers with volumes varying from 3 to 1800 cm 3 , and can be cylindrical, spherical or plane parallel plates kind. They usually are sensitive to photon particles, with energies greater than 15 keV and can be used up to 1200 keV. In this work they were tested in X radiation fields from 25 to 150 kV, in specific qualities depending on the utilization of the instrument. The calibration results of 390 instruments received from 2005 to 2007 were analyzed. About 20 instruments were not able to be calibrated due to bad functioning. The calibration coefficients obtained were between 0.88 and 1.24. The uncertainties were always less than ± 3.6% to instruments used in scattered
International Nuclear Information System (INIS)
Ondra, F.; Vasko, M.; Necas, V.
2012-01-01
An important part of nuclear installation decommissioning is conditional release of materials. The mass of conditionally released materials can significantly influence radioactive waste management and capacity of radioactive waste repository. The influence on a total decommissioning cost is also not negligible. Several scenarios for reuse of conditionally released materials were developed within CONRELMAT project. Each scenario contains preparation phase, construction phase and operation phase. For each above mentioned phase is needed to determine radiological, material, organizational and other constraints for conditionally released materials reuse to not break exposure limits for staff and public. Constraints are determined on the basis of external and internal exposure calculations in created models for selected takes in particular scenarios phases. The paper presents a developed methodology for determination of part of above mentioned constraints concerning external exposure of staff or public. Values of staff external exposure are also presented in paper to ensure that staff or public exposure does not break the limits. The methodology comprises a proposal of following constraints: radionuclide limit concentration of conditionally released materials for specific scenarios and nuclide vectors, specific deployment of conditionally released materials eventually shielding materials, staff and public during the scenario's phases, organizational measures concerning time of staff's or public's stay in the vicinity of conditionally released materials for individual performed scenarios and nuclide vectors. The paper further describes VISIPLAN 3D ALARA calculation planning software tool used for calculation of staff's and public's external exposure for individual scenarios. Several other parallel papers proposed for HND2012 are presenting selected details of the project.(author).
Radiological transport aspects of radioactive materials in Brazil
International Nuclear Information System (INIS)
Arrieta, C.M.A.; Guimaraes, C.A.; Meldonian, N.L.
1986-01-01
Many different types of radioactive materials are transported annually throughout the country, mainly those related with the nuclear fuel cycle and with the use in medicine, industry, agriculture and research fields. Considering the high number of packages that are transported by air and road a study is presented in order to assess their radiological aspects. For this purpose, data concerning the most significant radioisotopes are pointed out, including their activities and doses incurred by workers. (Author) [pt
International Nuclear Information System (INIS)
Sharma, Ranjit; Chatterjee, M.K.; Singh, Rajvir; Pradeepkumar, K.S.
2010-01-01
Nuclear and other radioactive materials may get smuggled into the country aimed at malicious acts. Radioactive material detected accidentally or during inspection at the entry points/national borders may indicate illicit trafficking for the purpose of nuclear/radiological terrorism. As country requires prevention and preparedness for response to these malicious acts, nuclear forensic techniques are to be developed incorporating radiological safety aspects. Nuclear forensics helps in determining the origin, intended use, legal owner and the smuggled route etc. by using fingerprinting as well as comparison with reference data. The suggested sequence of methods for analysis of radioactive material/samples will be radiological assessment, physical characterization, traditional forensic analysis, isotope analysis along with elemental/chemical analysis
International Nuclear Information System (INIS)
Harris, R.A.
1995-12-01
The objective of the characterization was to determine the extent of radiological contamination and presence of hazardous materials, to allow the preparation of an accurate cost estimate, and to plan for pre-demolition cleanup work to support building isolation. The scope of services for the project included the following tasks: Records Review and Interviews; Site Reconnaissance; Radiological Survey; and Sampling and Analysis
International Nuclear Information System (INIS)
Foltman, A.; Newsom, D.; Lerner, K.
1988-01-01
The nuclear industry has extensive radiological emergency planning (REP) experience that is directly applicable to hazardous materials emergency planning. Recently, the Feed Materials Production Center near Cincinnati, Ohio, successfully demonstrated such application. The REP experience includes conceptual bases and standards for developing plans that have been tested in hundreds of full-scale exercises. The exercise program itself is also well developed. Systematic consideration of the differences between chemical and radiological hazards shows that relatively minor changes to the REP bases and standards are necessary. Conduct of full-scale, REP-type exercises serves to test the plans, provide training, and engender confidence and credibility
International Nuclear Information System (INIS)
Nass, Jens
2010-01-01
The report on the risk of attacks with chemical, biological, radiological and nuclear weapons or materials covers the following topics: the variety of terrorism: ethnic-nationalistic, politically motivated, social revolutionary, political extremism, religious fanaticism, governmental terrorism; CBRN (chemical, biological, radiological, nuclear) weapons and materials: their availability and effectiveness in case of use; potential actor groups; prevention and counter measures, emergency and mitigating measures.
International Nuclear Information System (INIS)
Hochel, R.C.
1999-01-01
The cost effective radiological classification and disposal of solid materials with potential volume contamination, in accordance with applicable U.S. Department of Energy (DOE) Orders, suffers from an inability to unambiguously distinguish among transuranic waste, low-level waste, and unconditional-release materials in a generic way allowing in-situ measurement and verification. Depending on a material''s classification, disposal costs can vary by a hundred-fold. With these large costs at risk, the issues involved in making defensible decisions are ripe for closer scrutiny. In many cases, key issues can be easily resolved by a combination of process information, some simple measurements, and calculational predictions from a computer model for radiation shielding. The proper classification and disposal of many solid wastes requires a measurement regime that is able to show compliance with a variety of institutional and regulatory contamination limits. Ultimate responsibility for this, of course, rests with radiological control or health physics organization of the individual site, but there are many measurements which can be performed by operations and generation organizations to simplify the process and virtually guarantee acceptance. Although this is not possible for all potential solid wastes, there are many that do lend themselves to such measures, particularly some of large volumes and realizable cost savings. Mostly what is needed for this to happen are a few guiding rules, measurement procedures, and cross checks for potential pitfalls. Several examples are presented here and discussed that demonstrate the possibilities, including one which was successfully applied to bulk contamination
Handbook of radiologic procedures
International Nuclear Information System (INIS)
Hedgcock, M.
1986-01-01
This book is organized around radiologic procedures with each discussed from the points of view of: indications, contraindications, materials, method of procedures and complications. Covered in this book are: emergency radiology chest radiology, bone radiology, gastrointestinal radiology, GU radiology, pediatric radiology, computerized tomography, neuroradiology, visceral and peripheral angiography, cardiovascular radiology, nuclear medicine, lymphangiography, and mammography
Radiological impact assessment of building materials on ordinary houses dwellers
International Nuclear Information System (INIS)
Campos, M.P. de.
1994-01-01
The radiological impact due to building materials on habitants living in the Santo Andre district of Sao Paulo state, Brazil, was assessed through the total effective dose equivalent rate determination, for external and internal irradiation. The effective dose equivalent rate for external irradiation was calculated by the gamma spectrometry determination of natural radionuclides specific activity in the dwelling materials. The effective dose equivalent rate due to 222 Rn inhalation was calculated through the radon indoor activity determination by using solid state nuclear track detectors. (author). 46 refs, 6 figs, 14 tabs
Lääperi, A L
1996-01-01
The purpose of this study was to analyse the cost structure of radiological procedures in the intermediary referral hospitals and general practice and to develop a cost accounting system for radiological examinations that takes into consideration all relevant cost factors and is suitable for management of radiology departments and regional planning of radiological resources. The material comprised 174,560 basic radiological examinations performed in 1991 at 5 intermediate referral hospitals and 13 public health centres in the Pirkanmaa Hospital District in Finland. All radiological departments in the hospitals were managed by a specialist in radiology. The radiology departments at the public health care centres operated on a self-referral basis by general practitioners. The data were extracted from examination lists, inventories and balance sheets; parts of the data were estimated or calculated. The radiological examinations were compiled according to the type of examination and equipment used: conventional, contrast medium, ultrasound, mammography and roentgen examinations with mobile equipment. The majority of the examinations (87%) comprised conventional radiography. For cost analysis the cost items were grouped into 5 cost factors: personnel, equipment, material, real estate and administration costs. The depreciation time used was 10 years for roentgen equipment, 5 years for ultrasound equipment and 5 to 10 years for other capital goods. An annual interest rate of 10% was applied. Standard average values based on a sample at 2 hospitals were used for the examination-specific radiologist time, radiographer time and material costs. Four cost accounting versions with varying allocation of the major cost items were designed. Two-way analysis of variance of the effect of different allocation methods on the costs and cost structure of the examination groups was performed. On the basis of the cost analysis a cost accounting program containing both monetary and
Radiological aspects of the usability of red mud as building material additive
International Nuclear Information System (INIS)
Somlai, Janos; Jobbagy, Viktor; Kovacs, Jozsef; Tarjan, Sandor; Kovacs, Tibor
2008-01-01
Several researchers have examined and achieved favourable results in connection with the building industry's use of red mud extracted in large quantities from the processing of bauxite. These days more and more precedence is being given to limiting the radiological dose to the population. In this study carried out in Hungary, the use of red mud, bauxite, and clay additives recommended for the production of special cements, were examined from a radiological aspect. 226 Ra and 232 Th activity concentrations measured in Hungarian bauxite, red mud and clay samples were significantly similar with the levels for such raw materials mentioned in international literature. Taking radiation protection aspects into consideration, none of these products can be directly used for building construction. Taking Hungarian and international values into consideration, a small amount of red mud, not exceeding 15% could be used for brick production, for example as a colouring material. However, beyond this amount the standards for building materials would not be met. For the production of cements an even stricter limit needs to be determined when both bauxite and red mud are used
Natural radioactivity in granite stones and their radiological aspects as building material
International Nuclear Information System (INIS)
Kumaravel, S.; Sunil, C.N.; Narashimha Nath, V.; Raghunath, T.; Prashanth Kumar, M.; Ramakrishna, V.; Nair, B.S.K.; Purohit, R.G.; Tripati, R.M.
2014-01-01
Natural radioactivity in building and building decorating materials comes mainly from natural radioactive series like 238 U, 232 Th and 40 K. India is one of the leading users of granite stones as it is preferred by decorators and architects. The knowledge of presence of natural radioactivity in these materials is required for the assessment of radiation exposure due to them. The objective of this study is to determine the natural radioactivity and radiological aspects of granite stones as building material
Clearance of slightly radioactive material from radiological control in Germany
International Nuclear Information System (INIS)
Thierfeldt, S.
1995-01-01
Clearance from radiological control of slightly radioactive material arising from operation or decommissioning of nuclear installations has been practiced in Germany for nearly two decades. Meanwhile, for the clearance of metal generally approved and applicable recommendations for clearance levels have been issued. For other materials like building waste, case-by-case decisions are made by the state licensing authorities. Efforts to implement consistent sets of clearance levels for all kinds of material are under way. As several decommissioning projects will soon generate large amounts of materials from dismantling, a solution needs to be reached soon. The legal framework in Germany governing the use of atomic energy consists of the Atomic Energy Act and several ordinances. Rules and guidelines including the recommendations of the German Commission for Radiation Protection (SSK) exist on a lower level and are not legally binding. Several generic studies for the derivation of clearance levels for metals and building debris with alpha, beta, and gamma contamination have been performed on behalf of the Federal Ministry for Environment, Nature Conservation and Nuclear Safety, which oriented themselves on an individual dose of 10 microSv/a in agreement with IAEA recommendations. Stochastic models have been used for establishing the connection between specific activity of the material to be released and the resulting individual doses, with significant advantages over deterministic scenarios. In the future, for new SSK recommendations or an ordinance on clearance, the increase of masses from demolition of installations, higher recycling rates in the conventional sector and harmonization with international regulations and standards have to be taken into account
The radiological installation in dental office: selection and performance
International Nuclear Information System (INIS)
Cirre, Christian
2010-01-01
This thesis for a PhD in dental surgery aimed at identifying and analysing different ways to optimise radiographs. In a first part, the author presents the characteristics of X rays, and dosimetric values used in dental offices. He describes the interaction of X rays with living cells by recalling the discovery of biological effects and the emergence of radiation protection, and by discussing the consequences for the patient as well as for the practician. In the next part, the author comments technological advances of devices, and means available to practicians to improve their performance. He presents X ray tubes, discusses factors which influence ray production, and selection criteria, indicates additional devices (beam application tubes, filtration, collimation), discusses the selection of the receiver (types of receivers used in intra-oral radiology, digital or silver film-based sensors), and describes the picture-taking process (radiological techniques, use of angulators and lead shielding). He finally discusses how to optimise intra-oral dental imagery through good practices which comprise optimisation, selection of apparatuses and devices, performance of the radiological act with a patient sitting in the armchair, and maintenance of a good image quality [fr
International Nuclear Information System (INIS)
Kim, Jin Suh; Kim, Jae Kyun; Han, Dong Bok; Lim, Tae Hwan
1997-01-01
The purpose of this study was to determine current trends and the mode of future development in the field of medical radiology and to promote research among the nation's radiologists by analyzing the contents of the Journal of the Korean Radiologic Society(JKRS) and Radiology. The number of articles published in JKRS each year between 1990 and 1994 was counted. The research articles in JKRS(n=740) and in Radiology(n=1748) between 1992 and 1994 were categorized according to the objective, type, topic, materials, and radiologic techniques of their contents on the basis of predetermined criteria. Domestic Masters theses(n=126) and doctoral dissertations(n=75) accepted between 1990 and 1994, and domestic materials published in international journals (n=416) between 1986 and 1994 were also categorized using the same criteria. The greatest increase in the number of articles published in JKRS was seen during 1994. The majority of these aimed to retrospectively analyse the findings of diseases while the majority of articles published in Radiology dealt prospectively with the development and/or evaluation of diagnostic methods. More variety of topics and issues was seen in Radiology than in JKRS. The number of articles of domestic materials published in international journals increased from 1986 to 1994, while the number of articles of foreign materials published in Korea was relatively stationary : A significant number of theses and dissertations dealt, mostly prospectively, with studies of pathophysiologic and/or pharmacologic mechanisms using animal models. In order to understand both current trends and the direction and mode of future developments in the field of radiology, and to be able to actively deal with challenges at the forefront of radiologic development, it is essential to review research articles published in radiology-related journals
ICPP radiological and toxicological sabotage analysis
International Nuclear Information System (INIS)
Kubiak, V.R.; Mortensen, F.G.
1995-01-01
In June of 1993, the Department of Energy (DOE) issued Notice 5630.3A, open-quotes Protection of Departmental Facilities Against Radiological and Toxicological Sabotage,close quotes which states that all significant radiological and toxicological hazards at Department facilities must be examined for potential sabotage. This analysis has been completed at the Idaho Chemical Processing Plant (ICPP). The ICPP radiological and toxicological hazards include spent government and commercial fuels, Special Nuclear Materials (SNM), high-level liquid wastes, high-level solid wastes, and process and decontamination chemicals. The analysis effort included identification and assessment of quantities of hazardous materials present at the facility; identification and ranking of hazardous material targets; development of worst case scenarios detailing possible sabotage actions and hazard releases; performance of vulnerability assessments using table top and computer methodologies on credible threat targets; evaluation of potential risks to the public, workers, and the environment; evaluation of sabotage risk reduction options; and selection of cost effective prevention and mitigation options
Human performance in radiological survey scanning
International Nuclear Information System (INIS)
Brown, W.S.; Abelquist, E.W.
1998-03-01
The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor's performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors' performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments
Human performance in radiological survey scanning
Energy Technology Data Exchange (ETDEWEB)
Brown, W.S. [Brookhaven National Lab., Upton, NY (United States); Abelquist, E.W. [Oak Ridge Inst. for Science and Education, TN (United States)
1998-03-01
The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor`s performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors` performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments.
Belfi, Lily M; Bartolotta, Roger J; Giambrone, Ashley E; Davi, Caryn; Min, Robert J
2015-06-01
Among methods of "blended learning" (ie, combining online modules with in-class instruction), the "flipped classroom" involves student preclass review of material while reserving class time for interactive knowledge application. We integrated blended learning methodology in a "flipped" introductory clerkship in radiology, and assessed the impact of this approach on the student educational experience (performance and perception). In preparation for the "flipped clerkship," radiology faculty and residents created e-learning modules that were uploaded to an open-source website. The clerkship's 101 rising third-year medical students were exposed to different teaching methods during the course, such as blended learning, traditional lecture learning, and independent learning. Students completed precourse and postcourse knowledge assessments and surveys. Student knowledge improved overall as a result of taking the course. Blended learning achieved greater pretest to post-test improvement of high statistical significance (P value, .0060) compared to lecture learning alone. Blended learning also achieved greater pretest to post-test improvement of borderline statistical significance (P value, .0855) in comparison to independent learning alone. The difference in effectiveness of independent learning versus lecture learning was not statistically significant (P value, .2730). Student perceptions of the online modules used in blended learning portions of the course were very positive. They specifically enjoyed the self-paced interactivity and the ability to return to the modules in the future. Blended learning can be successfully applied to the introductory clerkship in radiology. This teaching method offers educators an innovative and efficient approach to medical student education in radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
Energy Technology Data Exchange (ETDEWEB)
Hochel, R.C.
1999-11-19
The cost effective radiological classification and disposal of solid materials with potential volume contamination, in accordance with applicable U.S. Department of Energy (DOE) Orders, suffers from an inability to unambiguously distinguish among transuranic waste, low-level waste, and unconditional-release materials in a generic way allowing in-situ measurement and verification. Depending on a material''s classification, disposal costs can vary by a hundred-fold. With these large costs at risk, the issues involved in making defensible decisions are ripe for closer scrutiny. In many cases, key issues can be easily resolved by a combination of process information, some simple measurements, and calculational predictions from a computer model for radiation shielding. The proper classification and disposal of many solid wastes requires a measurement regime that is able to show compliance with a variety of institutional and regulatory contamination limits. Ultimate responsibility for this, of course, rests with radiological control or health physics organization of the individual site, but there are many measurements which can be performed by operations and generation organizations to simplify the process and virtually guarantee acceptance. Although this is not possible for all potential solid wastes, there are many that do lend themselves to such measures, particularly some of large volumes and realizable cost savings. Mostly what is needed for this to happen are a few guiding rules, measurement procedures, and cross checks for potential pitfalls. Several examples are presented here and discussed that demonstrate the possibilities, including one which was successfully applied to bulk contamination.
International Nuclear Information System (INIS)
Margeanu, C.A.
2011-01-01
Nowadays, one of the most serious terrorist threats implies radiological dispersal devices (RDDs), the so-called dirty bombs, that combine a conventional explosive surrounded by an inflammatory material (like thermit) with radioactive material. The paper objective is to evaluate the radiological impact due to direct exposure to a RDD using a sealed radiation source (used for medical and industrial applications) as radioactive material. The simulations were performed for 60Co, 137Cs and 192Ir radiation sources. In order to model the contamination potential level and radiation exposure due to radioactive material spreading from RDD, Lawrence Livermore National Laboratory's HOTSPOT 2.07 computer code was used. The worst case scenario has been considered, calculations being performed for two radioactive material dispersion models, namely General radioactive Plume and General Explosion. Following parameters evolution with distance from the radiation source was investigated: total effective dose equivalent, time-integrated air concentration, ground surface deposition and ground shine dose rates. Comparisons between considered radiation sources and radioactive material dispersion models have been performed. The most drastic effects on population and the environment characterize 60Co sealed radiation source use in RDD.
Radiological Worker Training: Radiological Worker 2 lesson plans
International Nuclear Information System (INIS)
1992-10-01
Upon completion of this g course, the participant will have the knowledge to work safely in areas controlled for a radiological purposes using proper radiological practices. The participant will be able toidentify the fundamentals of radiation, radioactive material and radioactive contamination includes identify the three basic particles of an atom, define ionization, define ionizing radiation, radioactive material and radioactive contamination, distinguish between ionizing radiation and non-ionizing radiation, define radioactivity and radioactive half-life
International Nuclear Information System (INIS)
Hautecouverture, Benjamin
2009-10-01
Even if a 'dirty bomb' has never been used to date, the perception of the existence of a threat is shared by many. Four main types of radiological and nuclear terrorist attacks can be outlined: - acquisition and use of a nuclear weapon, - attacks and acts of sabotage against a nuclear reactor or another nuclear facility, - acquisition of fissile material for the elaboration of an Improvised Nuclear Device, - terrorist use of radiological materials for the elaboration of a Radiological Dispersal Device (RDD). This paper seeks to evaluate the probability for a terrorist group to acquire and make use of radiological materials in the objective of detonating a RDD, and the current international framework put into place to address such a threat. Is an international regime to cover radiological materials already in place? How comprehensive / integrated is it? Does a new and/or separate system need to be set up? Before 9/11, two events in particular served to illustrate the threat of a radiological or nuclear terrorist attack: Moscow in 1996, Argun in 1998. Since the 9/11 attacks, a few other radiological events have occurred, which could suggest that the threat is becoming more pressing. It must be noted that the use of a dirty bomb by a terrorist group would most probably be aimed at the contamination of a given geographical area, rather than mass destruction and killing. Indeed, the lethal impact of such weapons remains limited. For this reason, dirty bombs are considered by analysts as weapons of mass disruption rather than weapons of mass destruction. Impacts would be more important in the psychological or economic realms: - targeting highly populated environments, such as cities, would most probably not result in a high death toll; - compared with impacts on health, psychological impacts of such an attack would be much more serious, both within and outside the targeted population; - economic damage is probably the greatest threat posed by such attacks, particularly
Sorbent materials for rapid remediation of wash water during radiological event relief
Energy Technology Data Exchange (ETDEWEB)
Jolin, William C.; Kaminski, Michael
2016-11-01
Procedures for removing harmful radiation from interior and exterior surfaces of homes and businesses after a nuclear or radiological disaster may generate large volumes of radiologically contaminated waste water. Rather than releasing this waste water to potentially contaminate surrounding areas, it is preferable to treat it onsite. Retention barrels are a viable option because of their simplicity in preparation and availability of possible sorbent materials. This study investigated the use of aluminosilicate clay minerals as sorbent materials to retain 137Cs, 85Sr, and 152Eu. Vermiculite strongly retained 137Cs, though other radionuclides displayed diminished affinity for the surface. Montmorillonite exhibited increased affinity to sorb 85Sr and 152Eu in the presence of higher concentrations of 137Cs. To simulate flow within retention barrels, vermiculite was mixed with sand and used in small-scale column experiments. The GoldSim contaminate fate module was used to model breakthrough and assess the feasibility of using clay minerals as sorbent materials in retention barrels. The modeled radionuclide breakthrough profiles suggest that vermiculite-sand and montmorillonite-sand filled barrels could be used for treatment of contaminated water generated from field operations.
International Nuclear Information System (INIS)
Mommaert, Chantal; Andrieu, Caroline; Desnoyers, Yvon; Denis Pombet; Salsac, Marie-Delphine; Knaack, Michael; Altavilla, Massimo; Manes, Daniela; Takahashi, Hiroaki; Ul Syed, Naeem; Palomo, Nieves Martin; Larsson, Arne; Dunlop, Alister; Susan Brown; Emptage, Matthew; Black, Greg; Abu-Eid, Rateb; Szilagyi, Andrew; Weber, Inge; )
2017-01-01
Radiological characterisation is a key enabling activity for the planning and implementation of nuclear facility decommissioning. Effective characterisation allows the extent, location and nature of contamination to be determined and provides crucial information for facility dismantling, the management of material and waste arisings, the protection of workers, the public and the environment, and associated cost estimations. This report will be useful for characterisation practitioners who carry out tactical planning, preparation, optimisation and implementation of characterisation to support the decommissioning of nuclear facilities and the management of associated materials and waste. It compiles recent experience from NEA member countries in radiological characterisation, including from international experts, international case studies, an international conference, and international standards and guidance. Using this comprehensive evidence base, the report identifies relevant good practice and provides practical advice covering all stages of the characterisation process
Energy Technology Data Exchange (ETDEWEB)
1993-04-01
This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.
International Nuclear Information System (INIS)
1993-04-01
This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records
International Nuclear Information System (INIS)
2015-01-01
This publication provides guidance on performing specific assessments of candidate materials for dumping at sea, to determine whether the materials are de minimis in the meaning of the Convention on the Prevention of Marine Pollution by Dumping of Wastes and Other Matter 1972 (the London Convention 1972) and the related Protocol 1996 (the London Protocol 1996). It presents a detailed radiological procedure to assess doses to workers and members of the public and doses to marine flora and fauna related to the dumping of materials at sea. The procedures in this publication follow the requirements to protect the environment in the IAEA Safety Standards and in the recommendations by the International Commission of Radiological Protection. It is expected to be used by national regulatory authorities responsible for authorizing disposal at sea of candidate materials as well as by those companies and individuals applying to obtain permission to dispose these materials at sea
Radiology Technician, 10-5. Military Curriculum Materials for Vocational and Technical Education.
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
These five volumes of student materials for a secondary/postsecondary level course in radiology technology comprise one of a number of military-developed curriculum packages selected for adaptation to vocational instruction and curriculum development in a civilian setting. The purpose stated for the course is to provide the theory portion of…
International Nuclear Information System (INIS)
Margeanu, C.A.; Olteanu, G.; Bujoreanu, D.
2009-01-01
The hazardous waste problem imposes to respect national and international agreed regulations regarding their transport, taking into account both for maintaining humans, goods and environment exposure under specified limits, during transport and specific additional operations, and also to reduce impact on the environment. The paper follows to estimate the radiological risk and cask materials qualification according to the design specifications for disposed sealed radioactive sources normal transport situation. The shielding analysis has been performed by using Oak Ridge National Laboratory's SCALE 5 programs package. For thermal analysis and cask materials qualification ANSYS computer code has been used. Results have been obtained under the framework of Advanced system for monitoring of hazardous waste transport on the Romanian territory Research Project which main objective consists in implementation of a complex dual system for on-line monitoring both for transport special vehicle and hazardous waste packages, with data automatic transmission to a national monitoring center
Radiological Worker Training: Radiological Worker 1 lesson plans
International Nuclear Information System (INIS)
1992-10-01
Upon completion of this training course, the participant will have the knowledge to work safely in areas controlled for radiological purposes using proper radiological practices. Upon completion of this unit the participant will be able to identify the fundamentals of radiation, radioactive material and radioactive contamination. The participant will be able to select the correct response from a group of responses which verifies his/her ability to: Define ionizing radiation, radioactive material and radioactive contamination and identify the units used to measure radiation and radioactivity
Radiological monitoring of food in Cuba
International Nuclear Information System (INIS)
Jerez V, S.F.
1996-01-01
The appearing of the problem for protecting the environment from radioactive contamination is not an accidental matter. The introduction into the earth crust of radioactive material coming from nuclear weapons, accidents, wastes, etc, has caused, as a consequence, the contamination of the biosphere. The extensive trade of food in our country has made necessary the establishment of radiological monitoring in food, which was organized by the Department of Public Health. The structure, functions, characteristics and aspects related to radiological monitoring of food in Cuba are shown in the present paper. The organization and resources for performing the monitoring program, both for normal conditions and for nuclear and/or radiological emergency cases, are detailed. (author). 12 refs., 2 figs
International Nuclear Information System (INIS)
2003-10-01
on conducting specific assessments to determine whether candidate materials for disposal at sea contained de minimis levels of radioactivity. This report contains guidance on performing specific assessments of candidate materials to determine whether the materials are de minimis in the meaning of the London Convention 1972. It follows the guidelines adopted by the Twenty-first Consultative Meeting of the London Convention 1972 that incorporate a Stepwise Evaluation Procedure for screening candidate material to determine if it can be treated as 'non-radioactive' (i.e. de minimis) under the Convention. Material that cannot be readily defined as de minimis on the basis of Steps 1 to 5 of the Stepwise Evaluation Procedure require a specific assessment at Step 6. Such an assessment is the subject of this report. The assessment process described in this report is based on an inherently conservative procedure consistent with the precautionary approach, provided for under the London Convention 1972. Its purpose is to ensure the use of conservative models and cautious assumptions that result in the overestimation of the doses due to candidate materials that might be disposed of at sea in near coastal waters under de minimis provisions. Accordingly, the radiological consequences of disposal at sea of de minimis materials in other areas of the continental shelf and deeper waters will result in much lower radiation exposures than those considered here. It must be stressed that any candidate materials designated as de minimis must comply with all other provisions of the Convention. Section 2 provides a summary of the Stepwise Evaluation Procedure as detailed in the guidelines and background information necessary to understand the context of this guidance. Section 3 describes in detail a procedure to conduct the specific radiological assessment of the disposal of a candidate material. It contains a schematic diagram illustrating the specific assessment process and components of
International Nuclear Information System (INIS)
Shigang Chao; Xinwei Lu; Mengmeng Zhang; Long Pang
2014-01-01
Natural radioactivity of the commonly used building materials in Xining of China was measured using gamma-ray spectrometer system comprising a NaI(Tl) detector. Radioactivity concentrations of 226 Ra, 232 Th and 40 K in the studied samples range from 11.6 to 120.6, 10.2 to 107.1 and 228.0 to 1,036.2 Bq kg -1 , respectively. The concentrations for these natural radionuclides were compared with the reported data of other countries and the mean value for soil. Radium equivalent activity, indoor air absorbed dose rate, annual effective dose rate as well as external and internal hazard indices were calculated to assess radiological hazards for people living in dwelling made of the building materials. The radiological hazard assessment results show that the studied building materials, except for some aerated concrete block samples, are safe for use in construction of dwellings in the study area and do not pose any significant source of radiation hazard. (author)
A Business Analytics Software Tool for Monitoring and Predicting Radiology Throughput Performance.
Jones, Stephen; Cournane, Seán; Sheehy, Niall; Hederman, Lucy
2016-12-01
Business analytics (BA) is increasingly being utilised by radiology departments to analyse and present data. It encompasses statistical analysis, forecasting and predictive modelling and is used as an umbrella term for decision support and business intelligence systems. The primary aim of this study was to determine whether utilising BA technologies could contribute towards improved decision support and resource management within radiology departments. A set of information technology requirements were identified with key stakeholders, and a prototype BA software tool was designed, developed and implemented. A qualitative evaluation of the tool was carried out through a series of semi-structured interviews with key stakeholders. Feedback was collated, and emergent themes were identified. The results indicated that BA software applications can provide visibility of radiology performance data across all time horizons. The study demonstrated that the tool could potentially assist with improving operational efficiencies and management of radiology resources.
Mobile autonomous robot for radiological surveys
International Nuclear Information System (INIS)
Dudar, A.M.; Wagner, D.G.; Teese, G.D.
1992-01-01
The robotics development group at the Savannah River Laboratory (SRL) is developing a mobile autonomous robot that performs radiological surveys of potentially contaminated floors. The robot is called SIMON, which stands for Semi-Intelligent Mobile Observing Navigator. Certain areas of SRL are classified as radiologically controlled areas (RCAs). In an RCA, radioactive materials are frequently handled by workers, and thus, the potential for contamination is ever present. Current methods used for floor radiological surveying includes labor-intensive manual scanning or random smearing of certain floor locations. An autonomous robot such as SIMON performs the surveying task in a much more efficient manner and will track down contamination before it is contacted by humans. SIMON scans floors at a speed of 1 in./s and stops and alarms upon encountering contamination. Its environment is well defined, consisting of smooth building floors with wide corridors. The kind of contaminations that SIMON is capable of detecting are alpha and beta-gamma. The contamination levels of interest are low to moderate
International Nuclear Information System (INIS)
Ortiz, J.; Ballesteros, L.; Gallardo, S.; Martorell, S.
2014-01-01
In this presentation, radiological characterization is done by gamma spectrometry various types of ceramic tiles and use as building material in relation to the potential radiological risk deriving from this use are discussed. The discussion includes both the rules of the countries being targeted as the new basic security policy (BSS) issued by the EU 2014. (Author)
Key Performance Indicators in Radiology: You Can't Manage What You Can't Measure.
Harvey, H Benjamin; Hassanzadeh, Elmira; Aran, Shima; Rosenthal, Daniel I; Thrall, James H; Abujudeh, Hani H
2016-01-01
Quality assurance (QA) is a fundamental component of every successful radiology operation. A radiology QA program must be able to efficiently and effectively monitor and respond to quality problems. However, as radiology QA has expanded into the depths of radiology operations, the task of defining and measuring quality has become more difficult. Key performance indicators (KPIs) are highly valuable data points and measurement tools that can be used to monitor and evaluate the quality of services provided by a radiology operation. As such, KPIs empower a radiology QA program to bridge normative understandings of health care quality with on-the-ground quality management. This review introduces the importance of KPIs in health care QA, a framework for structuring KPIs, a method to identify and tailor KPIs, and strategies to analyze and communicate KPI data that would drive process improvement. Adopting a KPI-driven QA program is both good for patient care and allows a radiology operation to demonstrate measurable value to other health care stakeholders. Copyright © 2015 Mosby, Inc. All rights reserved.
Energy Technology Data Exchange (ETDEWEB)
Nam, Ki Chul; Cheung, Hwan [Seoul National University Hospital, Seoul (Korea, Republic of)
1986-11-15
As the angiography in the field of radiological sciences is being increasingly diversified in its techniques, clinical applications of interventional radiology are rapidly increasing not only for its usefulness in simple diagnosis but for its capabilities of affording, by means of radiological surveillance, biological data such as those concerning tissues which are even substitutionary or supplementary to treatment of diseases. During the last 5 years from July 1980 to 1984 such applications in the cardiovascular division showed a trend of radical increase and thus emerging as a new domain of radiological medicine which has vast influence on diagnosis and treatment. The present treatise presents the results of research performed on the following: 1) Need for close coordination among physicians, radiologists, and nurses in the radiology department. 2) Need for prior explanation to the patient of the procedure to be followed to relieve his anxiety. 3) Checking of the angiographic equipment and selection of technical factors. 4) Proper management of manpower including medical radiologists and assistant radiologists. 5) Sterilization of auxiliary equipment required for surgical operation. 6) Selection of a catheter and control of clinical materials such as contrast agents. 7) Supplementary arrangements for speedy performance of clinical services.
Energy Technology Data Exchange (ETDEWEB)
Perez-Sanchez, Danyl [CIEMAT, Avenida Complutense 40, 28040, Madrid (Spain)
2013-07-01
As a result of a pilot project developed at the old Spanish 'Junta de Energia Nuclear' to extract uranium from ores, tailings materials were generated. Most of these residual materials were sent back to different uranium mines, but a small amount of it was mixed with conventional building materials and deposited near the old plant until the surrounding ground was flattened. The affected land is included in an area under institutional control and used as recreational area. At the time of processing, uranium isotopes were separated but other radionuclides of the uranium decay series as Th-230, Ra-226 and daughters remain in the residue. Recently, the analyses of samples taken at different ground's depths confirmed their presence. This paper presents the methodology used to calculate the derived concentration level to ensure that the reference dose level of 0.1 mSv y-1 used as radiological criteria. In this study, a radiological impact assessment was performed modeling the area as recreational scenario. The modelization study was carried out with the code RESRAD considering as exposure pathways, external irradiation, inadvertent ingestion of soil, inhalation of resuspended particles, and inhalation of radon (Rn-222). As result was concluded that, if the concentration of Ra-226 in the first 15 cm of soil is lower than, 0.34 Bq g{sup -1}, the dose would not exceed the reference dose. Applying this value as a derived concentration level and comparing with the results of measurements on the ground, some areas with a concentration of activity slightly higher than latter were found. In these zones the remediation proposal has been to cover with a layer of 15 cm of clean material. This action represents a reduction of 85% of the dose and ensures compliance with the reference dose. (authors)
Radiological aspects of Arthroplasties
International Nuclear Information System (INIS)
Garcia, Sara Eugenia; Barragan, John Henry; Narvaez, Jorge Andres
2008-01-01
The development of new surgical techniques, of new prosthetic materials, and the increase in life expectancy with greater coverage of health services has ugmented the performance of hip replacements in our country. The radiologist should be familiar with the different surgical techniques and prosthetic devices, the evaluation of its components and associated complications. The most frequently performed arthroplasties are: shoulder, elbow, hip and knee replacement. This article reviews the most frequent prosthetic devices used, the radiological aspects of arthroplasties and their most common complications.
International Nuclear Information System (INIS)
Chavez, Miguel
1997-03-01
This manual of use and accounting of material radioactive and procedures of radiological safety tries to facilitate workings of protection of material radioactive in services of medicine nuclear, during diagnosis (examinations with x-rays, or those that are made in nuclear medicine), or during the processing of diseases, mainly of the carcinomas (x-ray)
International Nuclear Information System (INIS)
SANDGREN, K.R.
2006-01-01
This document quantifies the offsite radiological consequence of the bounding mixing of incompatible materials accident for comparison with the 25 rem Evaluation Guideline established in Appendix A of DOE-STD-3009. The bounding accident is an inadvertent addition of acid to a waste tank. The calculated offsite dose does not challenge the Evaluation Guideline. Revision 4 updates the analysis to consider bulk chemical additions to single shell tanks (SSTs)
Energy Technology Data Exchange (ETDEWEB)
Clevert, D.-A.; Reiser, M. [Universitaetsklinikum Muenchen (Germany). Institut fuer klinische Radiologie; Jung, E.M.; Rupp, N. [Institut fuer diagnostische Radiologie, Passau (Germany)
2004-10-01
Purpose: To perform a cost analysis for assessing options of reorganizing material supplies and reducing costs of the radiology division through the introduction of a materials management system. Materials and Methods: A materials management system (Piranha, Boston Scientific) was installed on an existing computer system. All consumables were inventoried and entered into the system. An ABC analysis determined further action. On the basis of order frequencies and availability requirements for emergencies, safety levels were agreed with physicians and other medical staff. Inventory costs were computed using these data. The interest rate for the capital tied up in the inventory was 8% per year. Results: The inventory showed that the capital tied up in stocks was Euro 260,000 and 2001 and Euro 190,000 in 2002. A change in supply strategy reduced inventory cost in 2001 and 2002. Annual interest expense was lowered by Euro 18,420. Another saving of Euro 2,700 was achieved by a reduction in storage cost. Annual inventory turnover totaled Euro 298,000. The total cost cut through improved inventory management was Euro 21,120 per year, which is equivalent to 7% of the annual expenses. Adding the decline in the cost of shelf time overruns equal to 5% of the annual expenses, the saving was approximately 12% of total interventional radiology cost in 2001 and some 11% in 2002. Conclusion: Flexible supply strategies and the introduction of a materials management program can help to reduce inventory costs in interventional radiology divisions without any impact on service levels. (orig.)
Evidence-based Practice of Radiology.
Lavelle, Lisa P; Dunne, Ruth M; Carroll, Anne G; Malone, Dermot E
2015-10-01
Current health care reform in the United States is producing a shift in radiology practice from the traditional volume-based role of performing and interpreting a large number of examinations to providing a more affordable and higher-quality service centered on patient outcomes, which is described as a value-based approach to the provision of health care services. In the 1990 s, evidence-based medicine was defined as the integration of current best evidence with clinical expertise and patient values. When these methods are applied outside internal medicine, the process is called evidence-based practice (EBP). EBP facilitates understanding, interpretation, and application of the best current evidence into radiology practice, which optimizes patient care. It has been incorporated into "Practice-based Learning and Improvement" and "Systems-based Practice," which are two of the six core resident competencies of the Accreditation Council for Graduate Medical Education and two of the 12 American Board of Radiology milestones for diagnostic radiology. Noninterpretive skills, such as systems-based practice, are also formally assessed in the "Quality and Safety" section of the American Board of Radiology Core and Certifying examinations. This article describes (a) the EBP framework, with particular focus on its relevance to the American Board of Radiology certification and maintenance of certification curricula; (b) how EBP can be integrated into a residency program; and (c) the current value and likely place of EBP in the radiology information technology infrastructure. Online supplemental material is available for this article. © RSNA, 2015.
International Nuclear Information System (INIS)
York, David L.; Love, Tracia L.; Rochau, Gary Eugene
2005-01-01
Concerns over the illicit trafficking of radiological and nuclear materials were focused originally on the lack of security and accountability of such material throughout the former Soviet states. This is primarily attributed to the frequency of events that have occurred involving the theft and trafficking of critical material components that could be used to construct a Radiological Dispersal Device (RDD) or even a rudimentary nuclear device. However, with the continued expansion of nuclear technology and the deployment of a global nuclear fuel cycle these materials have become increasingly prevalent, affording a more diverse inventory of dangerous materials and dual-use items. To further complicate the matter, the list of nuclear consumers has grown to include: (1) Nation-states that have gone beyond the IAEA agreed framework and additional protocols concerning multiple nuclear fuel cycles and processes that reuse the fuel through reprocessing to exploit technologies previously confined to the more industrialized world; (2) Terrorist organizations seeking to acquire nuclear and radiological material due to the potential devastation and psychological effect of their use; (3) Organized crime, which has discovered a lucrative market in trafficking of illicit material to international actors and/or countries; and (4) Amateur smugglers trying to feed their families in a post-Soviet era. An initial look at trafficking trends of this type seems scattered and erratic, localized primarily to a select group of countries. This is not necessarily the case. The success with which other contraband has been smuggled throughout the world suggests that nuclear trafficking may be carried out with relative ease along the same routes by the same criminals or criminal organizations. Because of the inordinately high threat posed by terrorist or extremist groups acquiring the ingredients for unconventional weapons, it is necessary that illicit trafficking of these materials be better
Secondary electron interactions in materials with environmental and radiological interest
International Nuclear Information System (INIS)
Garcia, G.; Blanco, F.; Pablos, J.L. de; Perez, J.M.; Williart, A.
2003-01-01
Important environmental and radiological applications require energy deposition models including the interactions between secondary electrons and the atoms or molecules of the medium. In this work we propose a method to obtain reliable cross-section data to be used in these models by combining total and ionization cross-section measurements with simple calculations of the differential and integral elastic cross-sections. The energy loss spectra obtained in this experiment have been also used to drive stopping power of the considered materials for electrons. Some examples of results for atomic (Xe) and molecular (CF 4 ) targets are presented and discussed in this paper. (author)
Palliative Airway Stenting Performed Under Radiological Guidance and Local Anesthesia
International Nuclear Information System (INIS)
Profili, Stefano; Manca, Antonio; Feo, Claudio F.; Padua, Guglielmo; Ortu, Riccardo; Canalis, Giulio C.; Meloni, Giovanni B.
2007-01-01
Purpose. To assess the effectiveness of airway stenting performed exclusively under radiological guidance for the palliation of malignant tracheobronchial strictures. Methods. We report our experience in 16 patients with malignant tracheobronchial stricture treated by insertion of 20 Ultraflex self-expandable metal stents performed under fluoroscopic guidance only. Three patients presented dysphagia grade IV due to esophageal malignant infiltration; they therefore underwent combined airway and esophageal stenting. All the procedures were performed under conscious sedation in the radiological room; average procedure time was around 10 min, but the airway impediment never lasted more than 40 sec. Results. We obtained an overall technical success in 16 cases (100%) and clinical success in 14 patients (88%). All prostheses were successfully placed without procedural complications. Rapid clinical improvement with symptom relief and normalization of respiratory function was obtained in 14 cases. Two patients died within 48 hr from causes unrelated to stent placement. Two cases (13%) of migration were observed; they were successfully treated with another stent. Tumor overgrowth developed in other 2 patients (13%); however, no further treatment was possible because of extensive laryngeal infiltration. Conclusions. Tracheobronchial recanalization with self-expandable metal stents is a safe and effective palliative treatment for malignant strictures. Airway stenting performed exclusively under fluoroscopic view was rapid and well tolerated
Mantero, J; Gazquez, M J; Bolivar, J P; Garcia-Tenorio, R; Vaca, F
2013-06-01
A study about the distribution of several radionuclides from the uranium and the thorium series radionuclides along the production process of a typical NORM industry devoted to the production of titanium dioxide has been performed. With this end the activity concentrations in raw materials, final product, co-products, and wastes of the production process have been determined by both gamma-ray and alpha-particle spectrometry. The main raw material used in the studied process (ilmenite) presents activity concentrations of around 300 Bq kg(-1) for Th-series radionuclides and 100 Bq kg(-1) for the U-series ones. These radionuclides in the industrial process are distributed in the different steps of the production process according mostly to the chemical behaviour of each radioelement, following different routes. As an example, most of the radium remains associated with the un-dissolved material waste, with activity concentrations around 3 kBq kg(-1) of (228)Ra and around 1 kBq kg(-1) of (226)Ra, while the final commercial products (TiO2 pigments and co-products) contain negligible amounts of radioactivity. The obtained results have allowed assessing the possible public radiological impact associated with the use of the products and co-products obtained in this type of industry, as well as the environmental radiological impact associated with the solid residues and liquid generated discharges. Copyright © 2013 Elsevier Ltd. All rights reserved.
International Nuclear Information System (INIS)
Livingstone, Roshan S.; Timothy Peace, B.S.; Sunny, S.; Victor Raj, D.
2007-01-01
Introduction: The advent of the computed radiography (CR) has brought about remarkable changes in the field of diagnostic radiology. A relatively large cross-section of the human population is exposed to ionizing radiation on account of common radiological investigations. This study is intended to audit radiation doses imparted to patients during common radiological investigations involving the use of CR systems. Method: The entrance surface doses (ESD) were measured using thermoluminescent dosimeters (TLD) for various radiological investigations performed using the computed radiography (CR) systems. Optimization of radiographic techniques and radiation doses was done by fine tuning the work practices. Results and conclusion: Reduction of radiation doses as high as 47% was achieved during certain investigations with the use of optimized exposure factors and fine-tuned work practices
Valorisation of phosphogypsum as building material: Radiological aspects
Directory of Open Access Journals (Sweden)
Tayibi, H.
2011-12-01
Full Text Available Nowadays, alternative uses of phosphogypsum (PG in the building industry are being considered in several countries; however, the natural radioactivity level in the PG could be a restriction for those uses. United States Environmental Protection Agency (US-EPA classified PG as Technologically Enhanced Naturally Occurring Radioactive Material (TENORM. This drawback could be avoided controlling its percentage in the cement preparation and the radionuclides content in the other raw materials used in its production, and calculating the activity concentration index (I in the final by-products.
The valorization of PG as a building material has been studied, from a radiological point of view, by developing a new stabilisation/solidification process. PG is incorporated within a polymeric sulphur matrix, obtaining a concrete-like material, which presents lower natural radioactive content than the initial PG. The 226Ra content of this material ranged between 26-27 Bq·kg-1 and it is quite similar to that of common Spanish building materials.
Actualmente, en muchos países se está contemplando el uso alternativo del fosfoyeso (PG en la industria de la construcción, aunque su contenido en radionucleidos naturales puede presentar ciertas restricciones para dicha aplicación (material clasificado por la US-EPA como TENORM: “Technologically Enhanced Naturally Occurring Materials. No obstante, estos inconvenientes podrían paliarse controlando el porcentaje del PG y los niveles de radioactividad en las materias primas a incorporar al cemento y calculando el índice de concentración de actividad (I en los productos finales.
La valorización del PG como material de construcción se ha estudiado en este trabajo desde el punto de vista radiológico, desarrollando un nuevo proceso de estabilización/solidificación, obteniéndose un material de características similares al cemento y que presenta menor contenido de radionucleidos naturales que el
Analysis of the Radiology Reports from Radiology Clinics
International Nuclear Information System (INIS)
Kim, Eun Jin; Kwack, Kyu Sung; Cho, Jae Hyun; Jang, Eun Ho
2009-01-01
The purpose of this study was to investigate the form and content of the radiology reports from radiology clinics in Korea. One hundred and sixty six radiology reports from 49 radiology clinics were collected, and these reports were referred to the academic tertiary medical center from March 2008 to February 2009. These included reports for CT (n = 18), MRI (n = 146) and examinations not specified (n = 2). Each report was evaluated for the presence of required contents (demographics, technical information, findings, conclusion, the name, license number and signature of the radiologist and the referring facility). These requirements were based on the guideline of the American College of Radiology and the previous research. The name of the patient, the gender, the body part, the type of examination, the time of examination and the conclusion, the name of the radiologist and the name of facility were well recorded in over 90% of the radiology reports. However, the identification number of the patient, the referring facility, the referring physician, the use of contrast material, the clinical information, the time of dictation, the signature of the radiologist and the license number of the radiologist were poorly recorded (less than 50%). The optimal format of a radiology report should be established for reliable and valid communication with clinicians
International Nuclear Information System (INIS)
Mueller-Neumann, M.
1992-01-01
The volume presents the full texts of the SSK Recommendations addressing the aspects and problems involved, and which can be separately retrieved from the database: 1) Radiological protection principles concerning the release of scrap from the shut-down of uranium mining plants; 2) Radiological protection principles concerning the release for industrial use of areas contaminated from uranium mining; 3) Radiological protection principles concerning the use for forest and agricultural purposes and as public gardens (parks) and residential areas of areas contaminated from uranium mining; 4) Radiological protection principles concerning the safeguard and use of mine dumps; 5) Radiological protection principles concerning the release for further commercial or industrial use of buildings used for commercial or industrial purposes and the disposal of building debris from uranium mining and milling; 6) Radiological protection principles concerning the release for general use of reusable equipment and installations from uranium mining. The following appendices round up the material: 1) Radiation exposure from mining in Saxony and Thuringia and its evaluation (Summary of the results of consultations during the 1990 closed meeting); 2) Radiological protection principles for the limitation of the radiation exposure of the public to radon and its daughters; 3) Epidemiological studies on the health state of the inhabitants of the mining region and the miners in Saxony and Thuringia. (orig.) [de
International Nuclear Information System (INIS)
Jefferson, R.M.
1990-01-01
This paper discusses how medical personnel faced with treating victims of an accident involving radioactive material should be suspicious concerning possible radiological involvement. At the same time, they should be careful to obtain the necessary information in order to make a rational decision as to the likelihood of such involvement. Having made that decision, it is entirely possible then to approach the problem from a medical standpoint in such a way as to determine the extent of radiological involvement and to apply proper medical treatment consistent with that exposure
324 Building Baseline Radiological Characterization
International Nuclear Information System (INIS)
Reeder, R.J.; Cooper, J.C.
2010-01-01
This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building. A total of 85 technical (100 square centimeter (cm 2 )) smears were collected from the Room 147 hoods, the Shielded Materials Facility (SMF), and the Radiochemical Engineering Cells (REC). Exposure rate readings (window open and window closed) were taken at a distance of 2.5 centimeters (cm) and 30 cm from the surface of each smear. Gross beta-gamma and alpha counts of each smear were also performed. The smear samples were analyzed by gamma energy analysis (GEA). Alpha energy analysis (AEA) and strontium-90 analysis were also performed on selected smears. GEA results for one or more samples reported the presence of manganese-54, cobalt-60, silver-108m antimony-125, cesium-134, cesium-137, europium-154, europium-155, and americium-241. AEA results reported the presence of plutonium-239/240, plutonium-238/ 241 Am, curium-243/244, curium-242, and americium-243. Tables 5 through 9 present a summary by location of the estimated maximum removable and total contamination levels in the Room 147 hoods, the SMF, and the REC. The smear sample survey data and laboratory analytical results are presented in tabular form by sample in Appendix A. The Appendix A tables combine survey data documented in radiological survey reports found in Appendix B and laboratory analytical results reported in the 324 Building Physical and Radiological Characterization Study (Berk, Hill, and Landsman 1998), supplemented by the laboratory analytical results found in Appendix C.
Radiological/toxicological sabotage assessments at the Savannah River Site
International Nuclear Information System (INIS)
Johnson, H.D.; Pascal, M.D.; Richardson, D.L.
1995-01-01
This paper describes the methods being employed by Westinghouse Savannah River Company (WSRC) to perform graded assessments of radiological and toxicological sabotage vulnerability at Savannah River Site (SRS) facilities. These assessments are conducted to ensure that effective measures are in place to prevent, mitigate, and respond to a potential sabotage event which may cause an airborne release of radiological/toxicological material, causing an adverse effect on the health and safety of employees, the public, and the environment. Department of Energy (DOE) Notice 5630.3A, open-quotes Protection of Departmental Facilities Against Radiological and Toxicological Sabotage,close quotes and the associated April 1993 DOE-Headquarters guidance provide the requirements and outline an eight-step process for hazardous material evaluation. The process requires the integration of information from a variety of disciplines, including safety, safeguards and security, and emergency preparedness. This paper summarizes WSRC's approach towards implementation of the DOE requirements, and explains the inter-relationships between the Radiological and Toxicological Assessments developed using this process, and facility Hazard Assessment Reports (HAs), Safety Analysis Reports (SARs), and Facility Vulnerability Assessments (VAs)
International Nuclear Information System (INIS)
Lopez V, J.; Capadona, N.
2006-01-01
The present work has by objective to indicate rules for the establishment and the use of the Radiological Protection Programs (PPR) that are of application to the transport of radioactive materials according to that required by the Transport Regulation of the International Atomic Energy Agency (IAEA). The PPR are established and applied in systematic form for remittent, transport and addressees, to consider the measures of radiological protection and its appropriately control during the transport stages of radioactive material. In particular, in the work it is analyzed the PPR applied to the operative stage, in the one that can be considered as one of the more important documents to use since it summarizes the evaluations and the necessary controls of radiological protection. Also it is analyzed the importance that this document gets ready on the base that it converges in the the analyses, evaluations and data that have been kept in mind during the previous stages of design of bundles and production of packings, the types and quantities of involved bundles, as well as of considering the quantities of expeditions and its frequencies, the ways of transport, etc. It is included a brief description of the parts that the PPR conforms on the base of that suggested in the advanced draft of the TS-G-1.5 Guide 'Radiation Protection Programmes for Transport of Radioactive Material', of October, 2005, of the IAEA: objectives. necessity, scope, basic elements of a PPR in function of the occupational dose. assignment of functions and responsibilities for the establishment of a PPR, evaluation and dose optimization, surface contamination, segregation and other protection measures, responses in emergencies. training and administration systems for baled and transport of radioactive material. Next an example of PPR for the transport of bundles of the A Type by lorry with content of radiopharmaceuticals that are the bundles more used worldwide in the expeditions of radioactive
International Nuclear Information System (INIS)
Gray, I.L.S.; Lange, F.; Hoermann, E.; Carr, N.A.
2004-01-01
be reached; Some terms, such as ''distributed throughout'', are not well defined, and this makes it difficult to demonstrate unequivocal compliance with the regulatory requirements; The relevance of the leaching test for LSA-III material is not obvious, and the test is very difficult to perform in practice; Even trace quantities of materials that are forbidden can bring compliance into question. There is consequently a need for improvements concerning the material specifications of the IAEA Transport Regulations and for a radiological model that allows new activity limits to be derived in connection with an alternative system of requirements
RADRELAY RADIOLOGICAL DATA LINK DEVICE
International Nuclear Information System (INIS)
Harpring, L.; Frank Heckendorn, F.
2007-01-01
The RadRelay effort developed small, field appropriate, portable prototype devices that allow radiological spectra to be downloaded from field radiological detectors, like the identiFINDER-U, and transmitted to land based experts. This communications capability was designed for the U. S. Coast Guard (USCG) but is also applicable to the Customs and Border Protection (CBP) personnel working in remote locations. USCG Level II personnel currently use the identiFINDER-U Hand-Held Radioisotope ID Devices (HHRIID) to detect radiological materials during specific boarding operations. These devices will detect not only radiological emissions but will also evaluate those emissions against a table of known radiological spectra. The RadRelay has been developed to significantly improve the functionality of HHRIID, by providing the capability to download radiological spectra and then transmit them using satellite or cell phone technology. This remote wireless data transfer reduces the current lengthy delay often encountered between the shipboard detection of unknown radiological material and the evaluation of that data by technical and command personnel. That delay is reduced from hours to minutes and allows the field located personnel to remain on station during the inspection and evaluation process
Asaduzzaman, Khandoker; Mannan, Farhana; Khandaker, Mayeen Uddin; Farook, Mohideen Salihu; Elkezza, Aeman; Amin, Yusoff Bin Mohd; Sharma, Sailesh; Abu Kassim, Hasan Bin
2015-01-01
The concentrations of primordial radionuclides (226Ra, 232Th and 40K) in commonly used building materials (brick, cement and sand), the raw materials of cement and the by-products of coal-fired power plants (fly ash) collected from various manufacturers and suppliers in Bangladesh were determined via gamma-ray spectrometry using an HPGe detector. The results showed that the mean concentrations of 226Ra, 232Th and 40K in all studied samples slightly exceeded the typical world average values of 50 Bq kg(-1), 50 Bq kg(-1) and 500 Bq kg(-1), respectively. The activity concentrations (especially 226Ra) of fly-ash-containing cement in this study were found to be higher than those of fly-ash-free cement. To evaluate the potential radiological risk to individuals associated with these building materials, various radiological hazard indicators were calculated. The radium equivalent activity values for all samples were found to be lower than the recommended limit for building materials of 370 Bq kg(-1), with the exception of the fly ash. For most samples, the values of the alpha index and the radiological hazard (external and internal) indices were found to be within the safe limit of 1. The mean indoor absorbed dose rate was observed to be higher than the population-weighted world average of 84 nGy h(-1), and the corresponding annual effective dose for most samples fell below the recommended upper dose limit of 1 mSv y(-1). For all investigated materials, the values of the gamma index were found to be greater than 0.5 but less than 1, indicating that the gamma dose contribution from the studied building materials exceeds the exemption dose criterion of 0.3 mSv y(-1) but complies with the upper dose principle of 1 mSv y(-1).
Unenhanced computed tomography in acute renal colic reduces cost outside radiology department
DEFF Research Database (Denmark)
Lauritsen, J.; Andersen, J.R.; Nordling, J.
2008-01-01
BACKGROUND: Unenhanced multidetector computed tomography (UMDCT) is well established as the procedure of choice for radiologic evaluation of patients with renal colic. The procedure has both clinical and financial consequences for departments of surgery and radiology. However, the financial effect...... outside the radiology department is poorly elucidated. PURPOSE: To evaluate the financial consequences outside of the radiology department, a retrospective study comparing the ward occupation of patients examined with UMDCT to that of intravenous urography (IVU) was performed. MATERIAL AND METHODS......) saved the hospital USD 265,000 every 6 months compared to the use of IVU. CONCLUSION: Use of UMDCT compared to IVU in patients with renal colic leads to cost savings outside the radiology department Udgivelsesdato: 2008/12...
Lim-Dunham, Jennifer E; Ensminger, David C; McNulty, John A; Hoyt, Amy E; Chandrasekhar, Arcot J
2016-02-01
The principles of Collins' cognitive apprenticeship model were used to design a radiology curriculum in which medical students practice radiological skills using online case-based modules. The modules are embedded within clinical third-year clerkships, and students are provided with personalized feedback from the instructors. We describe the development of the vertical online radiology curriculum and evaluate its impact on student achievement and learning process using a mixed method approach. The curriculum was developed over a 2-year period. Student participation was voluntary in the first year and mandatory in the second year. For quantitative curriculum evaluation, student metrics for voluntary versus mandatory groups were assessed using independent sample t tests and variable entry method regression analysis. For qualitative analysis, responses from a survey of students about the value of the curriculum were organized into defined themes using consensus coding. Mandatory participation significantly improved (p = .001) the mean radiology examination score (82 %) compared to the voluntary group (73%), suggesting that mandatory participation had a beneficial effect on student performance. Potential preexisting differences in underlying general academic performance were accounted for by including mean basic science grades as the first variable in the regression model. The significant increase in R(2) from .16 to .28 when number of radiology cases completed was added to the original model, and the greater value of the standardized beta for this variable, suggest that the curriculum made a significant contribution to students' radiology examination scores beyond their baseline academic performance. Five dominant themes about curricular characteristics that enhanced student learning and beneficial outcomes emerged from consensus coding. These themes were (1) self-paced design, (2) receiving feedback from faculty, (3) clinical relevance of cases, (4) gaining
Radiological properties of a wax-gypsum compensator material
International Nuclear Information System (INIS)
Plessis, F.C.P. du; Willemse, C.A.
2005-01-01
In this paper the radiological properties of a compensator material consisting of wax and gypsum is presented. Effective attenuation coefficients (EACs) have been determined from transmission measurements with an ion chamber in a Perspex phantom. Measurements were made at 80 and 100 cm source-to-skin distance (SSD) for beam energies of 6, 8, and 15 MV, for field sizes ranging from narrow beam geometries up to 40x40 cm 2 , and at measurement depths of maximum dose build-up, 5 and 10 cm. A parametrization equation could be constructed to predict the EAC values within 4% uncertainty as a function of field size and depth of measurement. The EAC dependence on off-axis position was also quantified at each beam energy and SSD. It was found that the compensator material reduced the required thickness for compensation by 26% at 8 MV when compared to pure paraffin wax for a 10x10 cm 2 field. Relative surface ionization (RSI) measurements have been made to quantify the effect of scattered electrons from the wax-gypsum compensator. Results indicated that for 80 cm SSD the RSI would exceed 50% for fields larger than 15x15 cm 2 . At 100 cm SSD the RSI values were below 50% for all field sizes used
International Nuclear Information System (INIS)
Larsson, C.L.
2004-12-01
An assessment of the availability of radioactive material used for medical applications in Canada has been performed as part of the CBRN Research and Technology Initiative (CRTI) Project CRTI-02-0024RD (Probabilistic Risk Assessment Tool for Radiological Dispersal Devices). A general list of medical radioisotopes used worldwide was compiled via literature searches and Internet investigations. This list was then compared to all isotopes licenced to healthcare facilities in Canada. Sources of lesser concern for this study, such as noble gases, short-lived isotopes, and radioisotopes not licenced for medical applications in Canada, were eliminated. The remaining sources were then analysed for frequency of use and maximum licenced activity to assess which materials would be of highest concern in relation to radiological terrorism. A detailed description of the application, typical administered activity, and other relevant information for these most common and highest licenced activity medical sources was assembled to feed directly into the risk assessment database. A general discussion of security in healthcare facilities is also given. Due to the constant advances made in medicine, the information relating to licenced isotopes is dynamic and thus requires updating to ensure the database is kept current. (author)
An honest day's work: pay for performance in a pediatric radiology department
International Nuclear Information System (INIS)
Bisset, George S.
2017-01-01
Compensation models in radiology take a variety of forms, but regardless of practice type, successful models must reward productivity, be simple, and epitomize fairness. The ideal model should also be flexible enough to transition, based upon the changing strategic goals of a department. The plan should be constructed around rewarding the behaviors that the organization values. In this minisymposium article the author presents the value of different types of compensation plans and discusses advantages and disadvantages. Finally, the author presents a pay-for-performance model that has had long-term success at a private-turned-academic practice in pediatric radiology. (orig.)
A َKalantari; SAM Khosravani
2014-01-01
Background & aim: Radiology personnel’s working in terms of performance and safety is one of the most important functions in order to increase the quality and quantity. This study aimed to evaluate the radiological standards in Shahid Beheshti Hospital of Yasuj, Iran, in 2013. Methods: The present cross-sectional study was based on a 118 randomly selected graphs and the ranking list, with full knowledge of the standards in radiology was performed two times. Data were analyzed using descri...
Radiology education: a radiology curriculum for all medical students?
Zwaan, Laura; Kok, E.M.; van der Gijp, Anouk
2017-01-01
Diagnostic errors in radiology are frequent and can cause severe patient harm. Despite large performance differences between radiologists and non-radiology physicians, the latter often interpret medical images because electronic health records make images available throughout the hospital. Some
Physical and cognitive task analysis in interventional radiology
Energy Technology Data Exchange (ETDEWEB)
Johnson, S [School of Psychology, University of Liverpool, Liverpool (United Kingdom); Healey, A [Royal Liverpool University Hospital, Liverpool (United Kingdom); Evans, J [Royal Liverpool University Hospital, Liverpool (United Kingdom); Murphy, M [Royal Liverpool University Hospital, Liverpool (United Kingdom); Crawshaw, M [Department of Psychology, University of Hull, Hull (United Kingdom); Gould, D [Royal Liverpool University Hospital, Liverpool (United Kingdom)
2006-01-15
AIM: To identify, describe and detail the cognitive thought processes, decision-making, and physical actions involved in the preparation and successful performance of core interventional radiology procedures. MATERIALS AND METHODS: Five commonly performed core interventional radiology procedures were selected for cognitive task analysis. Several examples of each procedure being performed by consultant interventional radiologists were videoed. The videos of those procedures, and the steps required for successful outcome, were analysed by a psychologist and an interventional radiologist. Once a skeleton algorithm of the procedures was defined, further refinement was achieved using individual interview techniques with consultant interventional radiologists. Additionally a critique of each iteration of the established algorithm was sought from non-participating independent consultant interventional radiologists. RESULTS: Detailed task descriptions and decision protocols were developed for five interventional radiology procedures (arterial puncture, nephrostomy, venous access, biopsy-using both ultrasound and computed tomography, and percutaneous transhepatic cholangiogram). Identical tasks performed within these procedures were identified and standardized within the protocols. CONCLUSIONS: Complex procedures were broken down and their constituent processes identified. This might be suitable for use as a training protocol to provide a universally acceptable safe practice at the most fundamental level. It is envisaged that data collected in this way can be used as an educational resource for trainees and could provide the basis for a training curriculum in interventional radiology. It will direct trainees towards safe practice of the highest standard. It will also provide performance objectives of a simulator model.
Physical and cognitive task analysis in interventional radiology
International Nuclear Information System (INIS)
Johnson, S.; Healey, A.; Evans, J.; Murphy, M.; Crawshaw, M.; Gould, D.
2006-01-01
AIM: To identify, describe and detail the cognitive thought processes, decision-making, and physical actions involved in the preparation and successful performance of core interventional radiology procedures. MATERIALS AND METHODS: Five commonly performed core interventional radiology procedures were selected for cognitive task analysis. Several examples of each procedure being performed by consultant interventional radiologists were videoed. The videos of those procedures, and the steps required for successful outcome, were analysed by a psychologist and an interventional radiologist. Once a skeleton algorithm of the procedures was defined, further refinement was achieved using individual interview techniques with consultant interventional radiologists. Additionally a critique of each iteration of the established algorithm was sought from non-participating independent consultant interventional radiologists. RESULTS: Detailed task descriptions and decision protocols were developed for five interventional radiology procedures (arterial puncture, nephrostomy, venous access, biopsy-using both ultrasound and computed tomography, and percutaneous transhepatic cholangiogram). Identical tasks performed within these procedures were identified and standardized within the protocols. CONCLUSIONS: Complex procedures were broken down and their constituent processes identified. This might be suitable for use as a training protocol to provide a universally acceptable safe practice at the most fundamental level. It is envisaged that data collected in this way can be used as an educational resource for trainees and could provide the basis for a training curriculum in interventional radiology. It will direct trainees towards safe practice of the highest standard. It will also provide performance objectives of a simulator model
Energy Technology Data Exchange (ETDEWEB)
Ketelsen, D. [Tuebingen Univ. (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Talanow, R. [Cleveland Clinic, Cleveland, OH (United States). Abt. fuer Nuklearmedizin; Uder, M. [Erlangen-Nuernberg Univ. (Germany). Inst. fuer Diagnostische Radiologie; Grunewald, M. [Erlangen-Nuernberg Univ. (Germany). Nuklearmedizinische Klinik
2009-04-15
Purpose: The aim of the study was to analyze the availability of published radiological e-learning tools and to establish a solution for quality assurance. Materials and Methods: Substantial pubmed research was performed to identify radiological e-learning tools. 181 e-learning programs were selected. As examples two databases expanding their programs with external links, Compare (n = 435 external links) and TNT-Radiology (n = 1078 external links), were evaluated. A concept for quality assurance was developed by an international taskforce. Results: At the time of assessment, 56.4 % (102/181) of the investigated e-learning tools were accessible at their original URL. A subgroup analysis of programs published 5 to 8 years ago showed significantly inferior availability to programs published 3 to 5 years ago (p < 0.01). The analysis of external links showed 49.2 % and 61.0 % accessible links for the programs Compare (published 2003) and TNT-Radiology (published 2006), respectively. As a consequence, the domain www.eLearning-radiology.com was developed by the taskforce and published online. This tool allows authors to present their programs and users to evaluate the e-learning tools depending on several criteria in order to remove inoperable links and to obtain information about the complexity and quality of the e-learning tools. (orig.)
International Nuclear Information System (INIS)
1981-07-01
This report is issued as guidance to those fuel cycle and major materials licensees who are required by the NRC to prepare and submit a radiological contingency plan. This Standard Format has been prepared to help assure uniformity and completeness in the preparation of those plans
Radiological clerkships as a critical curriculum component in radiology education
International Nuclear Information System (INIS)
Kourdioukova, Elena V.; Verstraete, Koenraad L.; Valcke, Martin
2011-01-01
Objective: The aim of this research was to explore the perceived value of clinical clerkships in the radiology curriculum as well as the impact of radiology clerkship on students' beliefs about the profession of radiology as a whole and as a career. Methods: This study is a sequel to a previous survey in which student perceptions about radiology curriculum components were investigated. The present study focuses on a further analysis of a subsection in this study, based on 14 statements about radiology clerkship and two statements about radiology as a career. Results: Perceived usefulness of the aspects of radiology clerkship as 'radiology examination', 'skills development' and 'diagnosis focus' were awarded the highest scores. The predict value of the subscale 'radiology examination' on the level of performance was very high (adjusted R 2 = 0.19, p < .001). Conclusion: Students expressed highly favorable evaluation of clerkship as a learning environment to learn to order and to interpret imaging studies as well as an unique possibility to attend various radiological examinations and to access to specific radiology software systems, as well as to get a better view on radiology and to improve image interpretation skills. This positive attitude towards clerkship is closely tied to students' beliefs about the profession of radiology as a whole. These aspects of dedicated radiology clerkship are crucial for effective and high-quality education as well as for the choice of radiology as a career.
Radiological Control Technician: Phase 1, Site academic training study guides
International Nuclear Information System (INIS)
1992-10-01
This volume is a study guide for training Radiological Control Technicians. Provided herein are support materials for learning radiological documentation, communication systems, counting errors and statistics, dosimetry, contamination control, airborne sampling program methods, respiratory protection, radiological source control, environmental monitoring, access control and work area setup, radiological work coverage, shipment and receipt for radioactive material, radiological incidents and emergencies, personnel decontamination, first aid, radiation survey instrumentation, contamination monitoring, air sampling, and counting room equipment
Radiological protection in interventional radiology
International Nuclear Information System (INIS)
Padovani, R.
2001-01-01
Interventional radiology (IR) reduces the need for many traditional interventions, particularly surgery, so reducing the discomfort and risk for patients compared with traditional systems. IR procedures are frequently performed by non-radiologist physicians, often without the proper radiological equipment and sufficient knowledge of radiation protection. Levels of doses to patients and staff in IR vary enormously. A poor correlation exists between patient and staff dose, and large variations of dose are reported for the same procedure. The occurrence of deterministic effects in patients is another peculiar aspect of IR owing to the potentially high skin doses of some procedures. The paper reviews the use of IR and the radiological protection of patients and staff, and examines the need for new standards for IR equipment and the training of personnel. (author)
SU-E-T-424: Feasibility of 3D Printed Radiological Equivalent Customizable Tissue Like Materials
Energy Technology Data Exchange (ETDEWEB)
Johnson, D; Ferreira, C; Ahmad, S [University of Oklahoma Health Science Center, Oklahoma City, OK (United States)
2015-06-15
Purpose: To investigate the feasibility of 3D printing CT# specific radiological equivalent tissue like materials. Methods: A desktop 3D printer was utilized to create a series of 3 cm x 3 cm x 2 cm PLA plastic blocks of varying fill densities. The fill pattern was selected to be hexagonal (Figure 1). A series of blocks was filled with paraffin and compared to a series filled with air. The blocks were evaluated with a “GE Lightspeed” 16 slice CT scanner and average CT# of the centers of the materials was determined. The attenuation properties of the subsequent blocks were also evaluated through their isocentric irradiation via “TrueBeam” accelerator under six beam energies. Blocks were placed upon plastic-water slabs of 4 cm in thickness assuring electronic equilibrium and data was collected via Sun Nuclear “Edge” diode detector. Relative changes in dose were compared with those predicted by Varian “Eclipse” TPS. Results: The CT# of 3D printed blocks was found to be a controllable variable. The fill material was able to narrow the range of variability in each sample. The attenuation of the block tracked with the density of the total fill structure. Assigned CT values in the TPS were seen to fall within an expected range predicted by the CT scans of the 3D printed blocks. Conclusion: We have demonstrated that it is possible to 3D print materials of varying tissue equivalencies, and that these materials have radiological properties that are customizable and predictable.
SU-E-T-424: Feasibility of 3D Printed Radiological Equivalent Customizable Tissue Like Materials
International Nuclear Information System (INIS)
Johnson, D; Ferreira, C; Ahmad, S
2015-01-01
Purpose: To investigate the feasibility of 3D printing CT# specific radiological equivalent tissue like materials. Methods: A desktop 3D printer was utilized to create a series of 3 cm x 3 cm x 2 cm PLA plastic blocks of varying fill densities. The fill pattern was selected to be hexagonal (Figure 1). A series of blocks was filled with paraffin and compared to a series filled with air. The blocks were evaluated with a “GE Lightspeed” 16 slice CT scanner and average CT# of the centers of the materials was determined. The attenuation properties of the subsequent blocks were also evaluated through their isocentric irradiation via “TrueBeam” accelerator under six beam energies. Blocks were placed upon plastic-water slabs of 4 cm in thickness assuring electronic equilibrium and data was collected via Sun Nuclear “Edge” diode detector. Relative changes in dose were compared with those predicted by Varian “Eclipse” TPS. Results: The CT# of 3D printed blocks was found to be a controllable variable. The fill material was able to narrow the range of variability in each sample. The attenuation of the block tracked with the density of the total fill structure. Assigned CT values in the TPS were seen to fall within an expected range predicted by the CT scans of the 3D printed blocks. Conclusion: We have demonstrated that it is possible to 3D print materials of varying tissue equivalencies, and that these materials have radiological properties that are customizable and predictable
Energy Technology Data Exchange (ETDEWEB)
Vainio, J; Rokkanen, P [Tampere Univ. (Finland). Inst. of Clinical Sciences; Central Hospital, Tampere (Finland))
1978-01-01
The potential of a bis-GMA composite resin as implant material in bone is evaluated. The material is claimed to have mechanical and physical properties superior to those of the bone cements used today. A groove made in the cortex of the tibia in 18 rats was filled with bis-GMA, while a similar was left empty in the contralateral tibia. The reaction of the bone to this material was evaluated by histologic, radiologic, microradiograph and OTC-fluorescence methods. The material was well tolerated by the bone; after 1,3 and 6 weeks no reaction to the material was observed.
The Effectiveness of Hypermedia Instructional Modules for Radiology Residents.
Shaw, Steven G.; And Others
1995-01-01
Details the development and field testing of hypermedia training materials for teaching radiology residents at the Montreal General Hospital (Canada). Compares results of randomly teaching 24 residents with either hypermedia or traditional classroom methods. Results indicate that residents who learned with hypermedia generally performed as well as…
Radiology Residents' Performance in Screening Mammography Interpretation
International Nuclear Information System (INIS)
Lee, Eun Hye; Lyou, Chae Yeon
2013-01-01
To evaluate radiology residents' performance in screening mammography interpretation and to analyze the factors affecting performance. We enrolled 203 residents from 21 institutions and performed mammography interpretation tests. Between the trainee and non-trainee groups, we compared the interpretation score, recall rate, sensitivity, positive predictive value (PPV) and false-positive rate (FPR). We estimated the training effect using the score differences between trainee and non-trainee groups. We analyzed the factors affecting performance between training-effective and non-effective groups. Trainees were superior to non-trainees regarding interpretation score (43.1 vs. 37.1), recall rate (11.0 vs. 15.5%), sensitivity (83.6 vs. 72.0%), PPV (53.0 vs. 32.4%) and FPR (13.5 vs. 25.5). The longer the training period, the better were the interpretation score, recall rate, sensitivity, PPV and FPR (rho = 0.486, -0.375, 0.343, 0.504, -0.446, respectively). The training affected an increase by an average of 6 points; however, 31.6% of institutions showed no effect. A difference was noted in the volume of mammography interpretation during a month (594.0 vs. 476.9) and dedication of breast staff (61.5 vs. 0%) between training-effective and non-effective groups. Trainees showed better performance in mammography interpretation compared to non-trainees. Moreover, performance was correlated with the training period. The factors affecting performance were the volume of mammography interpretation and the dedication of the breast staff.
Radiological analysis of materials sampled on the old nuclear test site of In Ekker (Algeria)
International Nuclear Information System (INIS)
Chareyron, Bruno
2010-01-01
After having recalled the context of the French nuclear test campaign in Algeria between 1961 and 1966, this document reports and comments radiological measurements performed on the site of In Ekker, and also results of analysis performed in laboratory (contamination by cesium 137, americium 241, plutonium); recommendations are given
Radiological Control Manual. Revision 0, January 1993
Energy Technology Data Exchange (ETDEWEB)
1993-04-01
This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.
E-learning and education in radiology
International Nuclear Information System (INIS)
Pinto, Antonio; Brunese, Luca; Pinto, Fabio; Acampora, Ciro; Romano, Luigia
2011-01-01
Purpose: To evaluate current applications of e-learning in radiology. Material and methods: A Medline search was performed using PubMed (National Library of Medicine, Bethesda, MD) for publications discussing the applications of e-learning in radiology. The search strategy employed a single combination of the following terms: (1) e-learning, and (2) education and (3) radiology. This review was limited to human studies and to English-language literature. We reviewed all the titles and subsequent the abstract of 29 articles that appeared pertinent. Additional articles were identified by reviewing the reference lists of relevant papers. Finally, the full text of 38 selected articles was reviewed. Results: Literature data shows that with the constant development of technology and global spread of computer networks, in particular of the Internet, the integration of multimedia and interactivity introduced into electronic publishing has allowed the creation of multimedia applications that provide valuable support for medical teaching and continuing medical education, specifically for radiology. Such technologies are valuable tools for collaboration, interactivity, simulation, and self-testing. However, not everything on the World Wide Web is useful, accurate, or beneficial: the quality and veracity of medical information on the World Wide Web is variable and much time can be wasted as many websites do not meet basic publication standards. Conclusion: E-learning will become an important source of education in radiology.
E-learning and education in radiology
Energy Technology Data Exchange (ETDEWEB)
Pinto, Antonio, E-mail: antopin1968@libero.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Brunese, Luca, E-mail: lucabrunese@libero.it [Department of Health Science, Faculty of Medicine and Surgery, University of Molise, I-86100 Campobasso (Italy); Pinto, Fabio, E-mail: fpinto1966@libero.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Acampora, Ciro, E-mail: itrasente@libero.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Romano, Luigia, E-mail: luigia.romano@fastwebnet.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy)
2011-06-15
Purpose: To evaluate current applications of e-learning in radiology. Material and methods: A Medline search was performed using PubMed (National Library of Medicine, Bethesda, MD) for publications discussing the applications of e-learning in radiology. The search strategy employed a single combination of the following terms: (1) e-learning, and (2) education and (3) radiology. This review was limited to human studies and to English-language literature. We reviewed all the titles and subsequent the abstract of 29 articles that appeared pertinent. Additional articles were identified by reviewing the reference lists of relevant papers. Finally, the full text of 38 selected articles was reviewed. Results: Literature data shows that with the constant development of technology and global spread of computer networks, in particular of the Internet, the integration of multimedia and interactivity introduced into electronic publishing has allowed the creation of multimedia applications that provide valuable support for medical teaching and continuing medical education, specifically for radiology. Such technologies are valuable tools for collaboration, interactivity, simulation, and self-testing. However, not everything on the World Wide Web is useful, accurate, or beneficial: the quality and veracity of medical information on the World Wide Web is variable and much time can be wasted as many websites do not meet basic publication standards. Conclusion: E-learning will become an important source of education in radiology.
International Nuclear Information System (INIS)
Taylor, J.M.; Daniel, S.L.; DuCharme, A.R.; Finley, N.N.
1977-01-01
A model has been developed which predicts the radiological consequences of the transportation of radioactive material in and around urban environments. This discussion of the model includes discussion of the following general topics: health effects from radiation exposure, urban area characterization, computation of dose resulting from normal transportation, computation of dose resulting from vehicular accidents or sabotage, and preliminary results and conclusions
Natural Language Processing in Radiology: A Systematic Review.
Pons, Ewoud; Braun, Loes M M; Hunink, M G Myriam; Kors, Jan A
2016-05-01
Radiological reporting has generated large quantities of digital content within the electronic health record, which is potentially a valuable source of information for improving clinical care and supporting research. Although radiology reports are stored for communication and documentation of diagnostic imaging, harnessing their potential requires efficient and automated information extraction: they exist mainly as free-text clinical narrative, from which it is a major challenge to obtain structured data. Natural language processing (NLP) provides techniques that aid the conversion of text into a structured representation, and thus enables computers to derive meaning from human (ie, natural language) input. Used on radiology reports, NLP techniques enable automatic identification and extraction of information. By exploring the various purposes for their use, this review examines how radiology benefits from NLP. A systematic literature search identified 67 relevant publications describing NLP methods that support practical applications in radiology. This review takes a close look at the individual studies in terms of tasks (ie, the extracted information), the NLP methodology and tools used, and their application purpose and performance results. Additionally, limitations, future challenges, and requirements for advancing NLP in radiology will be discussed. (©) RSNA, 2016 Online supplemental material is available for this article.
International Nuclear Information System (INIS)
Cowen, A.R.
1986-01-01
Over the preceding decade the Leeds Radiological Imaging Group have developed a range of test objects with which to assess the performance of radiological imaging systems. The types of imaging equipment which can be assessed include X-ray image intensifier television systems, small-format 100mm/105mm fluorography systems and radiographic screen-film combinations. We have recently extended our interest to the evaluation of digital radiological imaging equipment including digital subtraction fluorography and digital (greyscale) radiographic imaging systems. These test objects were initially developed for the purpose of evaluating imaging performance under laboratory conditions but they have also proved useful under field (clinical) conditions. (author)
International Nuclear Information System (INIS)
Woollam, P.B.
1984-08-01
This report considers whether it may be possible to reduce the radiological consequences of reactor decommissioning by careful attention to the specification of the elemental concentration of materials used in the reactor's construction. In particular, consideration is given to the potential for reduction of the concentration of elements known to activate to long lived daughter isotopes. Two particular areas are addressed, both applied to Sizewell 'B' PWR. The first is the choice of raw materials for the construction of the concrete bioshield to minimise future waste arisings. The second is the specification of some trace element concentrations in the steel pressure vessel and reactor internal structures to minimise personnel exposure at decommissioning time. The report presents extensive analyses of many of the candidate raw materials for Sizewell 'B' concrete, including PFA, and derives the radiological consequences for the eventual disposal of these materials to a hypothetical municipal land fill waste site. Data are also presented on the concentrations of important elements activating to gamma emitting daughters in type 304 stainless steels, leading to an assessment of likely dose equivalent rates at decommissioning time from the pressure vessel and from the internal components. (author)
Energy Technology Data Exchange (ETDEWEB)
Ferreira, C.C., E-mail: cassio.c.ferreira@gmail.co [Departamento de Fisica, Universidade Federal de Sergipe, Postal Code 353, Sergipe-SE 49100-000 (Brazil); Ximenes Filho, R.E.M., E-mail: raimundoximenes@hotmail.co [Departamento de Fisica, Universidade Federal de Sergipe, Postal Code 353, Sergipe-SE 49100-000 (Brazil); Vieira, J.W., E-mail: jwvieira@br.inter.ne [Centro Federal de Educacao Tecnologica de Pernambuco (CEFET-PE), Av. Professor Luiz Freire, 500 Curado, CEP 50740-540, Recife (Brazil); Escola Politecnica de Pernambuco, Universidade de Pernambuco (EPP/UPE), Rua Benfica, 455, Madalena, CEP 50720-001, Recife (Brazil); Tomal, A., E-mail: alessandratomal@pg.ffclrp.usp.b [Departamento de Fisica e Matematica, FFCLRP, Universidade de Sao Paulo, Ribeirao Preto-SP 14040-90 (Brazil); Poletti, M.E., E-mail: poletti@ffclrp.usp.b [Departamento de Fisica e Matematica, FFCLRP, Universidade de Sao Paulo, Ribeirao Preto-SP 14040-90 (Brazil); Garcia, C.A.B., E-mail: cgarcia@ufs.b [Departamento de Quimica, Universidade Federal de Sergipe, Postal Code 353, Sergipe-SE 49100-000 (Brazil); Maia, A.F., E-mail: afmaia@ufs.b [Departamento de Fisica, Universidade Federal de Sergipe, Postal Code 353, Sergipe-SE 49100-000 (Brazil)
2010-08-15
Tissue-equivalent materials to be used as substitutes for human brain tissue in dosimetry for diagnostic radiology have been investigated in terms of calculated total mass attenuation coefficient ({mu}/{rho}), calculated mass energy-absorption coefficient ({mu}{sub en}/{rho}) and absorbed dose. Measured linear attenuation coefficients ({mu}) have been used for benchmarking the calculated total mass attenuation coefficient ({mu}/{rho}). The materials examined were bolus, nylon (registered) , orange articulation wax, red articulation wax, PMMA (polymethylmethacrylate), bees wax, paraffin I, paraffin II, pitch and water. The results show that water is the best substitute for brain among the materials investigated. The average percentage differences between the calculated {mu}/{rho} and {mu}{sub en}/{rho} coefficients for water and those for brain were 1.0% and 2.5%, respectively. Absorbed doses determined by Monte Carlo methods confirm water as being the best brain substitute to be used in dosimetry for diagnostic radiology, showing maximum difference of 0.01%. Additionally this study showed that PMMA, a material often used for the manufacturing of head phantoms for computed tomography, cannot be considered to be a suitable substitute for human brain tissue in dosimetry.
Services of radiological protection: as sizing the human and material resources
International Nuclear Information System (INIS)
Rueda Guerrero, M. D.; Sierra Perler, I.; Lorenzo Perez, P.
2014-01-01
Discussion of radiological protection in the Middle Health has formed a task force to develop a technical document recommendatory to help plan and evaluate resources radiological protection services. (Author)
324 Building Baseline Radiological Characterization
Energy Technology Data Exchange (ETDEWEB)
R.J. Reeder, J.C. Cooper
2010-06-24
This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building.
Aerial vehicle with paint for detection of radiological and chemical warfare agents
Farmer, Joseph C.; Brunk, James L.; Day, S. Daniel
2013-04-02
A paint that warns of radiological or chemical substances comprising a paint operatively connected to the surface, an indicator material carried by the paint that provides an indication of the radiological or chemical substances, and a thermo-activation material carried by the paint. In one embodiment, a method of warning of radiological or chemical substances comprising the steps of painting a surface with an indicator material, and monitoring the surface for indications of the radiological or chemical substances. In another embodiment, a paint is operatively connected to a vehicle and an indicator material is carried by the paint that provides an indication of the radiological or chemical substances.
Energy Technology Data Exchange (ETDEWEB)
Hill, R.L.; Aaberg, R.L.; Baker, D.A.; Kennedy, W.E. Jr.
1995-07-01
Pacific Northwest Laboratory is providing Environmental Protection Support and Assistance to the USDOE, Office of Environmental Guidance. Air, Water, and Radiation Division. As part of this effort, PNL is collecting data and conducting technical evaluations to support DOE analyses of the feasibility of developing radiological control levels for recycling or reuse of metals, concrete, or equipment containing residual radioactive contamination from DOE operations. The radiological control levels will be risk-based, as developed through a radiation exposure scenario and pathway analysis. The analysis will include evaluation of relevant radionuclides, potential mechanisms of exposure, and both health and non-health-related impacts. The main objective of this report is to develop a methodology for establishing radiological control levels for recycle or reuse. This report provides the results of the radiation exposure scenario and pathway analyses for 42 key radionuclides generated during DOE operations that may be contained in metals or equipment considered for either recycling or reuse. The scenarios and information developed by the IAEA. Application of Exemption Principles to the Recycle and Reuse of Materials from Nuclear Facilities, are used as the initial basis for this study. The analyses were performed for both selected worker populations at metal smelters and for the public downwind of a smelter facility. Doses to the public downwind were estimated using the US (EPA) CAP88-PC computer code with generic data on atmospheric dispersion and population density. Potential non-health-related effects of residual activity on electronics and on film were also analyzed.
International Nuclear Information System (INIS)
Hill, R.L.; Aaberg, R.L.; Baker, D.A.; Kennedy, W.E. Jr.
1995-07-01
Pacific Northwest Laboratory is providing Environmental Protection Support and Assistance to the USDOE, Office of Environmental Guidance. Air, Water, and Radiation Division. As part of this effort, PNL is collecting data and conducting technical evaluations to support DOE analyses of the feasibility of developing radiological control levels for recycling or reuse of metals, concrete, or equipment containing residual radioactive contamination from DOE operations. The radiological control levels will be risk-based, as developed through a radiation exposure scenario and pathway analysis. The analysis will include evaluation of relevant radionuclides, potential mechanisms of exposure, and both health and non-health-related impacts. The main objective of this report is to develop a methodology for establishing radiological control levels for recycle or reuse. This report provides the results of the radiation exposure scenario and pathway analyses for 42 key radionuclides generated during DOE operations that may be contained in metals or equipment considered for either recycling or reuse. The scenarios and information developed by the IAEA. Application of Exemption Principles to the Recycle and Reuse of Materials from Nuclear Facilities, are used as the initial basis for this study. The analyses were performed for both selected worker populations at metal smelters and for the public downwind of a smelter facility. Doses to the public downwind were estimated using the US (EPA) CAP88-PC computer code with generic data on atmospheric dispersion and population density. Potential non-health-related effects of residual activity on electronics and on film were also analyzed
Radiologic protection in intensive therapy units
International Nuclear Information System (INIS)
Andrea, H.; Juliana, C.; Gerusa, R.; Laurete, M.B.; Suelen, S.; Derech, Rodrigo D.A.
2013-01-01
The discovery of X-ray was a great achievement for humanity, especially for the medical community. In Intensive Care Units (ICUs), the RX tests, performed with mobile devices, add immense value to the diagnosis of inpatients who do not have the option to carry them out of bed. Following the technology and its improvements, fatalities arose from misuse of ionizing radiation, which mostly gave up for lack of knowledge of the biological effects caused by them, which leads to fear among professionals and often prevents a quick job and effectively by professionals of radiological techniques. The research it is a systematic review of the literature and justified by the scarcity of materials that reflect on the radiological protection in ICUs. For this study we found the Virtual Health Library (VHL) and Pubmed were indexed terms radiological protection and intensive care units, the search in Portuguese and English terms were used radiological protection and intensive care unit. The study aims to inform professionals of ICUs on the main aspects that refer to X-rays in hospital beds, the standards of radiological protection and personal protective equipment, thus avoiding possible damage to the biological health of workers, addressing subjects in rules and laws about the X radiation, emphasizing the protection of professionals in intensive care. It is clear, finally, that little research is conducted in the context of radiological protection of workers ICU's and this is a place that receives daily RX equipment, deserving more attention to protect the worker. (author)
Energy Technology Data Exchange (ETDEWEB)
Gellermann, Rainer; Nickstadt, Kristin [Nuclear Control and Consulting GmbH, Braunschweig (Germany)
2014-10-01
During utilization of deep geothermal energy sources NORM waste accumulate with radiological properties similar to the residues from crude oil or natural gas production or water treatment plants. The specific activities of these waste materials are in the range from less than 1 Bq/g to more than 1000 Bq/g. The estimated total annual amount of radiological relevant materials (scales, combustible materials, scrap metals) is about 5 to 6 tons with a total activity of about 0.4 GBq Ra-226 and about 2 GBq Pb-210. The established disposal paths for metal waste exist.
Exercises for radiological and nuclear emergency response. Planing - performance - evaluation
International Nuclear Information System (INIS)
Bayer, A.; Faleschini, J.; Goelling, K.; Stapel, R.; Strobl, C.
2010-01-01
The report of the study group emergency response seminar covers the following topics: (A) purpose of exercises and exercise culture: fundamentals and appliances for planning, performance and evaluation; (B) exercises in nuclear facilities; (C) exercises of national authorities and aid organizations on nuclear scenarios; exercises of national authorities and aid organizations on other radiological scenarios; (D) exercises in industrial plants, universities, medical facilities and medical services, and research institutes; (E) transnational exercises, international exercises; (F): exercises on public information.
International Society of Radiology and Radiation Protection
International Nuclear Information System (INIS)
Standertskjoeld-Nordenstam, C.G.
2001-01-01
The purpose of the International Society of Radiology (ISR), as being the global organization of radiologists, is to promote and help co-ordinate the progress of radiology throughout the world. In this capacity and as a co-operating organization of the IAEA, the ISR has a specific responsibility in the global radiological protection of patients. Globally, there are many users of medical radiation, and radiology may be practised in the most awkward circumstances. The individuals performing X ray studies as well as those interpreting them may be well trained, as in industrialized parts of the world, but also less knowledgeable, as in developing areas. The problems of radiological protection, both of patients and of radiation workers, still exist, and radiation equipment is largely diffused throughout the world. That is why a conference like this is today as important as ever. Radiation protection is achieved through education, on the one hand, and legislation, on the other. Legislation and regulation are the instruments of national authorities. The means of the ISR are education and information. Good radiological practice is something that can be taught. The ISR is doing this mainly through the biannual International Congress of Radiology (ICR), now arranged in an area of radiological need; the three previous ICRs were in China, in India and in South America; the next one is going to be in Mexico in 2002. The goal of the ICR is mainly to be an instructive and educational event, especially designed for the needs of its surrounding region. The ISR is aiming at producing educational material. The International Commission on Radiological Education (ICRE), as part of the ISR, is launching the production of a series of educational booklets, which also include radiation protection. The ICRE is actively involved in shaping and organizing the educational and scientific programme of the ICRs
Interventional Radiology in Paediatrics.
Chippington, Samantha J; Goodwin, Susie J
2015-01-01
As in adult practice, there is a growing role for paediatric interventional radiology expertise in the management of paediatric pathologies. This review is targeted for clinicians who may refer their patients to paediatric interventional radiology services, or who are responsible for patients who are undergoing paediatric interventional radiology procedures. The article includes a brief overview of the indications for intervention, techniques involved and the commonest complications. Although some of the procedures described are most commonly performed in a tertiary paediatric centre, many are performed in most Children's hospitals.
International Nuclear Information System (INIS)
Keats, T.E.
1986-01-01
This book is the German, translated version of the original published in 1984 in the U.S.A., entitled 'Emergency Radiology'. The publication for the most part is made up as an atlas of the radiological images presenting the findings required for assessment of the emergency cases and their first treatment. The test parts' function is to explain the images and give the necessary information. The material is arranged in seven sections dealing with the skull, the facial part of the skull, the spine, thorax, abdominal region, the pelvis and the hip, and the limbs. With 690 figs [de
International Nuclear Information System (INIS)
Lopes, Amanda Gomes
2015-01-01
The handling of glassware in ampoules, containing solution is very common in research or production laboratories. During manipulation, there is a likelihood of occurrence of incidents such as the breaking of ampoules or glass vials containing material in liquid or powdered form which may cause a wound to the possibility of contamination with handled material. When the solution is radioactive there is a concern due to the risk of incorporation of that material. According to NCRP 156, the scientific literature contains over 2100 cases of wounds contaminated with radionuclides and more than 90% of the reported cases occurred in the hands and arms, but mainly on the fingers. Despite having no cases of wounds reported radioactive material in Brazil or a protocol developed by the National Agencies, applications and hence the manipulation of radionuclides is increasing in the country, rising the possibility of wound occurrence contaminated by radionuclides. In this work was proposed a methodology for management of individuals who suffered wounds from radioactive material in cases of nuclear accidents and radiological emergencies that present intake, which consisted of four steps: definition of the accident scenario, individual triage of the public or workers, proper measurements with detectors PRD, IdentiFINDER2 and germanium in different thicknesses material tissue-equivalent, and later adoption of first aid measures consisting of attendance, monitoring of contaminated personnel, evaluation of effective dose and direct to specialized medical center. As an example of results it follows the case of 241 Am where the best performance was obtained by measurements with the shielded HPGe (7%) and the shielded and collimation of 0.5 cm IdentiFINDER2 (10%). While, unshielded PRD, unshielded or shielded side IdentiFINDER2 and unshielded TeCd showed performance ranging from 30 to 70%. In general, the uncertainties obtained had values below 1.5%. In this work a protocol for
International Nuclear Information System (INIS)
Vieru, Gheorghe
2008-01-01
The transport of radioactive materials (RAM) is a very important problem considering the potential risks and radiological consequences in carrying-out this activity. Romania as a Member State of the International Atomic Energy Agency has implemented national regulations for a safe transport of RAM in accordance with the Agency's recommendations as well as other international specialized organizations. Based on the IAEA's Safety Standard-TS-R-1 (ST-1), Romanian National Nuclear Regulatory Body - CNCAN adopted and implemented, by Act no. 357/December 21, 2005, the safety regulations for the transport of radioactive materials in Romania under the title: 'Regulations for the Transport of Radioactive Materials'. The paper will present the main sources of radioactive materials in Romania their transportation routes with a particular interest paid to the radioactive wastes (low level radioactive materials), isotopes and radioactive sources, uranium ore. Starting from the fact that the safety in the transport of radioactive materials is dependent on appropriate packaging for the contents being shipped, rather than operational and/or administrative actions required for the package, the paper presents, briefly the main packages used for transport and storage of such RAM in Romania. There are presented hypothetical scenarios for specific problems related to the identification and evaluation of the risks and potential radiological consequences associated with the transport of radioactive materials in Romania, for all these three situations: routine transport (without incidents), normal transport (with minor incidents) and during possible accidents. As a conclusion, it is ascertained that the evaluated annual collective dose for the population due to RAM transport is less than that received by natural radiation sources. At the same time it is concluded that Romanian made packages are safe and prevent loss of their radioactive contents into the environment. (author)
Radiological safety training for uranium facilities
Energy Technology Data Exchange (ETDEWEB)
NONE
1998-02-01
This handbook contains recommended training materials consistent with DOE standardized core radiological training material. These materials consist of a program management guide, instructor`s guide, student guide, and overhead transparencies.
Natural radioactivity and radiological hazards of building materials in Xianyang, China
International Nuclear Information System (INIS)
Lu Xinwei; Yang Guang; Ren Chunhui
2012-01-01
Common building materials collected from Xianyang, China were analyzed for the natural radioactivity of 226 Ra, 232 Th and 40 K using γ-ray spectroscopy. The average activity concentration of 226 Ra, 232 Th and 40 K in the studied building materials ranges from 13.4 to 69.9, 13.1–99.1 and 124.7–915.1 Bq kg −1 , respectively. The measured activity concentrations for these radionuclides were compared with the reported data of other countries and with the worldwide average activity of soil. To assess the radiation hazard of the natural radioactivity in all samples to the people, the radium equivalent activity, external hazard index, internal hazard index, indoor absorbed dose rate and total annual effective dose were estimated. The radium equivalent activities of the studied samples are below the internationally accepted values. The external hazard index and internal hazard index of all analyzed building materials are less than unity. The mean values of indoor absorbed dose rate for all building materials except for lime are higher than the world population-weighted average of 84 nGy h −1 and the total annual effective dose values of building materials are lower than 1 mSv y −1 except for some cyan brick samples. The study shows the measured building materials do not pose significant source of radiation hazard and are safe for use in the construction of dwellings. - Highlights: ► Natural radioactivity in building materials was determined by gamma ray spectrometry. ► The radiological hazard of studied building materials is within the recommended safety limit. ► Most of the studied building materials do not pose significant radiation risk to residents.
Comparison of time-oriented cost accounting catalogs to control a Departement of Radiology
International Nuclear Information System (INIS)
Hacklaender, T.; Mertens, H.; Cramer, B.M.
2005-01-01
Purpose: Within a hospital, the radiology department has taken over the role of a cost center. Cost accounting can be applied to analyze the cost for the performance of services. By assigning the expenditures of resources to the service, the cash value can directly be distributed to the costs of equipment, material and rooms. Time-oriented catalogs of services are predefined to calculate the number of the employees for a radiology department. Using our own survey of time data, we examined whether such catalogs correctly represent the time consumed in a radiology department. Only services relevant for the turnover were compared. Materials and Methods: For 96 primary radiological services defined by the score-oriented German fee catalog for physicians (Gebuehrenordnung fuer Aerzte), a ranking list was made for the annual procedures in descending frequency order. According to the Pareto principle, the 11 services with the highest frequency were chosen and the time consumed for the technical and medical services was collected over a period of 2 months. This survey was compared with the time-oriented catalogs TARMED and EBM 2000plus. Results: The included 11 relevant radiological services represented 80.3% of the annual procedures of our radiology department. When comparing the technical services between the time-oriented catalogs and our own survey, TARMED gives a better description of the time consumed in 7 of the 11 services and EMB 2000plus in 3 services. When comparing the medical services, TARMED gives a better description of the time consumed in 6 of the 11 services and EBM 2000plus in 4 services. When averaging all the radiological services, TARMED overestimates the current number of physicians necessary for primary reading by a factor of 10.0% and EBM 2000plus by a factor of 2.6%. Conclusion: As to the time spent on performing the relevant radiological services. TARMED is slightly superior to describe the radiology department of a hospital than EBM 2000plus
Liang, Hui; DeWald, Janice P; Solomon, Eric S
2018-02-01
Dental hygiene students' performance in oral radiology courses may give an early indication of their readiness prior to taking the National Board Dental Hygiene Examination (NBDHE). The aim of this study was to determine the relationship between dental hygiene students' performance in an oral radiology lecture course and their performance on the NBDHE. Data were collected for all 117 dental hygiene students at Texas A&M University College of Dentistry from 2006 to 2009 who took the NBDHE during their second year of the program. Their final grades and scores on three written section examinations in an oral radiology course taken in their first year were compared with their overall NBDHE scores and raw scores on the oral radiology and case study sections. Moderate correlations (0.3radiology course, with the strongest correlation with the final grade (r=0.488, pradiology, followed by scores in anatomic sciences; the weakest relationship was with scores in pharmacology. This relationship can help identify students who may need extra support in the oral radiology course and other courses to prepare them to succeed when they take the NBDHE. This study also contributes to understanding of the general relationship between dental hygiene program courses and students' success on the clinical licensing exam and will hopefully encourage other programs to assess their students' performance in this way.
ASSET RECOVERY OF HAZARDOUS MATERIALS BENEFICIAL REUSE OF RADIOLOGICALLY ENCUMBERED LEAD STOCKS
International Nuclear Information System (INIS)
Lloyd, E.R.; Meehan, R.W.
2003-01-01
Underutilized and surplus lead stocks and leaded components are a common legacy environmental problem across much of the Department of Energy (DOE) Complex. While seeking to dispose of these items through its Environmental Management Program, DOE operational programs continue to pursue contemporary mission requirements such as managing and/or storing radioactive isotopes that require lead materials for shielding. This paradox was identified in late 1999 when DOE's policies for managing scrap metal were assessed. In January 2000, the Secretary of Energy directed the National Center of Excellence for Materials Recycle (NMR) to develop and implement a comprehensive lead reuse program for all of DOE. Fluor Hanford, contractor for DOE Richland Operations, subsequently contacted NMR to pilot lead reclamation and reuse at the Hanford Site. This relationship resulted in the development of a beneficial reuse pathway for lead reclaimed from spent fuel transport railcars being stored at Hanford. The 1.3 million pounds of lead in the railcars is considered radiologically encumbered due to its prior use. Further, the material was considered a mixed Resource Conservation and Recovery Act (RCRA) low-level radioactive waste that would require expensive storage or macro encapsulation to meet land disposal restrictions prior to burial. Working closely with Flour Hanford and the Office of Air, Water, and Radiation (EH-412), NMR developed a directed reuse pathway for this and other radiologically encumbered lead. When derived supplemental release limits were used, the lead recovered from these railcars became eligible for reuse in shielding products to support DOE and commercial nuclear industry operations. Using this disposition pathway has saved Hanford one third of the cost of disposing of the lead and the cost of acquiring additional lead for nuclear shielding applications. Furthermore, the environmental costs associated with mining and producing new lead for shielding products a
International Nuclear Information System (INIS)
1996-08-01
Two volumes contain more than 183 complete papers presented during the Third Regional Meeting on Radiological Protection and Nuclear Safety held on 23-27 October, 1995 in Cusco-Peru. Latin american specialist talk about nuclear safety and radiological protection, radiation natural exposure, biological effect of radiation, radiotherapy and medical radiological safety, radiological safety in industry and research. Also we deal with subjects related to radiological safety of nuclear and radioactive facilities, radioactive waste management, radioactive material transport, environmental radiological monitoring program, radiological emergency and accidents, instruments and dosimetry, basic safety standards of protection against radiation
Radiological control criteria for materials considered for recycle and reuse
International Nuclear Information System (INIS)
Kennedy, W.E. Jr.; Hill, R.L.; Aaberg, R.L.; Wallo, A. III
1994-11-01
Pacific Northwest Laboratory (PNL) is conducting technical analyses to support the US Department of Energy (DOE), Office of Environmental Guidance, Air, Water, and Radiation Division (DOE/EH-232) in developing radiological control criteria for recycling or reuse of metals or equipment containing residual radioactive contamination from DOE operations. The criteria, framed as acceptable concentrations for release of materials for recycling or reuse, are risk-based and were developed through analysis of generic radiation exposure scenarios and pathways. The analysis includes evaluation of relevant radionuclides, potential mechanisms of exposure, and non-health-related impacts of residual radioactivity on electronics and film. The analysis considers 42 key radionuclides that DOE operations are known to generate and that may be contained in recycled or reused metals or equipment. Preliminary results are compared with similar results reported by the International Atomic Energy Agency, by radionuclide grouping
International Nuclear Information System (INIS)
Smith, K.P.; Blunt, D.L.; Williams, G.P.; Tebes, C.L.
1995-01-01
A preliminary radiological dose assessment related to equipment decontamination, subsurface disposal, landspreading, equipment smelting, and equipment burial was conducted to address concerns regarding the presence of naturally occurring radioactive materials in production waste streams. The assessment evaluated the relative dose of these activities and included a sensitivity analysis of certain input parameters. Future studies and potential policy actions are recommended
An honest day's work: pay for performance in a pediatric radiology department
Energy Technology Data Exchange (ETDEWEB)
Bisset, George S. [Texas Children' s Hospital, Department of Radiology, Baylor College of Medicine, Houston, TX (United States)
2017-06-15
Compensation models in radiology take a variety of forms, but regardless of practice type, successful models must reward productivity, be simple, and epitomize fairness. The ideal model should also be flexible enough to transition, based upon the changing strategic goals of a department. The plan should be constructed around rewarding the behaviors that the organization values. In this minisymposium article the author presents the value of different types of compensation plans and discusses advantages and disadvantages. Finally, the author presents a pay-for-performance model that has had long-term success at a private-turned-academic practice in pediatric radiology. (orig.)
International Nuclear Information System (INIS)
Azorin N, J.; Azorin V, J. C.
2010-01-01
This work is directed to all those people related with the exercise of the radiological protection and has the purpose of providing them a base of knowledge in this discipline so that they can make decisions documented on technical and scientist factors for the protection of the personnel occupationally exposed, the people in general and the environment during the work with ionizing radiations. Before de lack of a text on this matter, this work seeks to cover the specific necessities of our country, providing a solid presentation of the radiological protection, included the bases of the radiations physics, the detection and radiation dosimetry, the radiobiology, the normative and operational procedures associates, the radioactive wastes, the emergencies and the transport of the radioactive material through the medical and industrial applications of the radiations, making emphasis in the relative particular aspects to the radiological protection in Mexico. The book have 16 chapters and with the purpose of supplementing the given information, are included at the end four appendixes: 1) the radioactive waste management in Mexico, 2-3) the Mexican official standards related with the radiological protection, 4) a terms glossary used in radiological protection. We hope this book will be of utility for those people that work in the investigation and the applications of the ionizing radiations. (Author)
Prabhu, Arpan V; Donovan, Ashley L; Crihalmeanu, Tudor; Hansberry, David R; Agarwal, Nitin; Beriwal, Sushil; Kale, Hrishikesh; Heller, Matthew
The internet creates opportunities for Americans to access medical information about imaging tests and modalities to guide them in their medical decision-making. Owing to health literacy variations in the general population, the American Medical Association and National Institutes of Health recommend patient education resources to be written between the third and seventh grade levels. Our purpose is to quantitatively assess the readability levels of online radiology educational materials, written for the public, in 20 major university hospitals. In September and October 2016, we identified 20 major university hospitals with radiology residency-affiliated hospital systems. On each hospital׳s website, we downloaded all radiology-related articles written for patient use. A total of 375 articles were analyzed for readability level using 9 quantitative readability scales that are well validated in the medical literature. The 375 articles from 20 hospital systems were collectively written at an 11.4 ± 3.0 grade level (range: 8.4-17.1). Only 11 (2.9%) articles were written at the recommended third to seventh grade levels. Overall, 126 (33.6%) were written above a full high-school reading level. University of Washington Medical Center׳s articles were the most readable with a reading level corresponding to 7.9 ± 0.9. The vast majority of websites at major academic hospitals with radiology residencies designed to provide patients with information about imaging were written above the nationally recommended health literacy guidelines to meet the needs of the average American. This may limit the benefit that patients can derive from these educational materials. Copyright © 2018 Elsevier Inc. All rights reserved.
eLearning-radiology.com. Sustainability for quality assurance
International Nuclear Information System (INIS)
Ketelsen, D.; Talanow, R.; Uder, M.; Grunewald, M.
2009-01-01
Purpose: The aim of the study was to analyze the availability of published radiological e-learning tools and to establish a solution for quality assurance. Materials and Methods: Substantial pubmed research was performed to identify radiological e-learning tools. 181 e-learning programs were selected. As examples two databases expanding their programs with external links, Compare (n = 435 external links) and TNT-Radiology (n = 1078 external links), were evaluated. A concept for quality assurance was developed by an international taskforce. Results: At the time of assessment, 56.4 % (102/181) of the investigated e-learning tools were accessible at their original URL. A subgroup analysis of programs published 5 to 8 years ago showed significantly inferior availability to programs published 3 to 5 years ago (p < 0.01). The analysis of external links showed 49.2 % and 61.0 % accessible links for the programs Compare (published 2003) and TNT-Radiology (published 2006), respectively. As a consequence, the domain www.eLearning-radiology.com was developed by the taskforce and published online. This tool allows authors to present their programs and users to evaluate the e-learning tools depending on several criteria in order to remove inoperable links and to obtain information about the complexity and quality of the e-learning tools. (orig.)
Radiological controls integrated into design
Energy Technology Data Exchange (ETDEWEB)
Kindred, G.W. [Cleveland Electric Illuminating Co., Perry, OH (United States)
1995-03-01
Radiological controls are required by law in the design of commercial nuclear power reactor facilities. These controls can be relatively minor or significant, relative to cost. To ensure that radiological controls are designed into a project, the health physicist (radiological engineer) must be involved from the beginning. This is especially true regarding keeping costs down. For every radiological engineer at a nuclear power plant there must be fifty engineers of other disciplines. The radiological engineer cannot be an expert on every discipline of engineering. However, he must be knowledgeable to the degree of how a design will impact the facility from a radiological perspective. This paper will address how to effectively perform radiological analyses with the goal of radiological controls integrated into the design package.
International Nuclear Information System (INIS)
Taylor, J.M.; Daniel, S.L.
1978-01-01
The analysis of accidental releases of radioactive material which may result from transportation accidents in high-density urban areas is influenced by several urban characteristics which make computer simulation the calculational method of choice. These urban features fall into four categories. Each of these categories contains time- and location-dependent parameters which must be coupled to the actual time and location of the release in the calculation of the anticipated radiological consequences. Due to the large number of dependent parameters a computer model, METRAN, has been developed to quantify these radiological consequences. Rather than attempt to describe an urban area as a single entity, a specific urban area is subdivided into a set of cells of fixed size to permit more detailed characterization. Initially, the study area is subdivided into a set of 2-dimensional cells. A uniform set of time-dependent physical characteristics which describe the land use, population distribution, traffic density, etc., within that cell are then computed from various data sources. The METRAN code incorporates several details of urban areas. A principal limitation of the analysis is the limited availability of accurate information to use as input data. Although the code was originally developed to analyze dispersal of radioactive material, it is currently being evaluated for use in analyzing the effects of dispersal of other hazardous materials in both urban and rural areas
Consequence Assessment for Potential Scenarios of Radiological Terrorists Events
International Nuclear Information System (INIS)
Shin, Hyeongki; Kim, Juyoul
2007-01-01
Radiological dispersal device (RDD) means any method used to deliberately disperse radioactive material to create terror or harm. Dirty bomb is an example of RDD, which usually consists of radioactive material and unconventional explosive. Dirty bomb was a problem long before September 11, 2001. In 1987, the Iraqi government tested a one-ton radiological bomb. The Iraqi tests confirmed that a dirty bomb is not effective as weapons of mass destruction (WMD) and that its main value is as a psychological weapon. In 1995, Chechen rebels buried a dirty bomb in a park in Moscow threatening to detonate one in the future if their demands were not met. Another good example of potential dirty bomb effects was an incident in Goiania, Brazil on September 18, 1987, where an orphaned medical source containing 1,375 Ci of Cs-137 resulted the death of four people and extensive environmental contamination. The purposes of radiological terrorists events are not to destroy or damage the target but to disperse radioactivity in the environment. They inflict panic on a public and economic damage by disruption of business. They also have influence on enormous clean-up costs by spreading radioactive contamination including secondary impacts on water supply reservoirs. Generally, two major long-term concerns following a RDD are human health and economic impacts. In this study, we developed potential scenarios of radiological terrorists events and performed their radiological consequence assessments in terms of total effective dose equivalent (TEDE), projected cumulative external and internal dose, and ground deposition of radioactivity
Consequence Assessment for Potential Scenarios of Radiological Terrorists Events
Energy Technology Data Exchange (ETDEWEB)
Shin, Hyeongki [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Kim, Juyoul [Seoul National University, Seoul (Korea, Republic of)
2007-07-01
Radiological dispersal device (RDD) means any method used to deliberately disperse radioactive material to create terror or harm. Dirty bomb is an example of RDD, which usually consists of radioactive material and unconventional explosive. Dirty bomb was a problem long before September 11, 2001. In 1987, the Iraqi government tested a one-ton radiological bomb. The Iraqi tests confirmed that a dirty bomb is not effective as weapons of mass destruction (WMD) and that its main value is as a psychological weapon. In 1995, Chechen rebels buried a dirty bomb in a park in Moscow threatening to detonate one in the future if their demands were not met. Another good example of potential dirty bomb effects was an incident in Goiania, Brazil on September 18, 1987, where an orphaned medical source containing 1,375 Ci of Cs-137 resulted the death of four people and extensive environmental contamination. The purposes of radiological terrorists events are not to destroy or damage the target but to disperse radioactivity in the environment. They inflict panic on a public and economic damage by disruption of business. They also have influence on enormous clean-up costs by spreading radioactive contamination including secondary impacts on water supply reservoirs. Generally, two major long-term concerns following a RDD are human health and economic impacts. In this study, we developed potential scenarios of radiological terrorists events and performed their radiological consequence assessments in terms of total effective dose equivalent (TEDE), projected cumulative external and internal dose, and ground deposition of radioactivity.
Virtual pilot course in radiological protection
International Nuclear Information System (INIS)
Gonzalez Romero, Angela Maria; Plazas, Maria Cristina
2008-01-01
Full text: The radiological protection performs vital importance in the fields medically, industrially and environmental. The X-rays and the radioactive materials used in medicine have allowed to realize important progresses and to develop new technologies skills for the diagnosis, the therapy and the prevention of diseases. Having in it counts tells the risks associated with the ionizing radiations, it is required legally that the personnel that intervenes in the different procedures has the necessary knowledge of radiological protection to assure that the use of radiations in the medical practice should carry out of ideal form, at the right moment and adopting all the necessary measures to guarantee the best protection, so much of the occupationally exposed personnel, since as, like of the patients and the public in general. The virtual environments for the construction of the knowledge like it is the virtual university, allows presenting an effective alternative in the learning of different areas and in this particular case of the radiological protection. With the aim lens to give response to these needs there is implemented this pilot virtual course year based on the current course of radiological protection that is dictated in the Mastery in Medical Physics of the National University of Colombia, sedate Bogota. The purpose of this virtual course is to use as academic and bibliographical support on radiological protection, as well as to answer to the needs of initial formation that the professionals have, to acquire a solid base in the mentioned matter. It has been conceived so that it provides theoretical formation, so much scientific as technology and that contemplates the recommendations and international and national procedure on radiological protection and some applications. Given the incorporation of the technologies of information and communication that in the academic area it has brought with it not only to give support to the curricular activities but
Radiological performance assessment for the E-Area Vaults Disposal Facility
International Nuclear Information System (INIS)
Cook, J.R.
2000-01-01
This report is the first revision to ''Radiological Performance Assessment for the E-Area Vaults Disposal Facility, Revision 0'', which was issued in April 1994 and received conditional DOE approval in September 1994. The title of this report has been changed to conform to the current name of the facility. The revision incorporates improved groundwater modeling methodology, which includes a large data base of site specific geotechnical data, and special Analyses on disposal of cement-based wasteforms and naval wastes, issued after publication of Revision 0
Radiological studies on Egyptian mummies
International Nuclear Information System (INIS)
Pahl, W.M.
1982-01-01
The goal of this work as part of a mummy study project is to obtain the maximum amount of information through radiological methods with the minimum destruction of the object. For this proven radiological methods were used as well as conventional radiological methods which had not yet been used with mummy research and modern radiological methods using an electronic basis relative to their importance for the study of medical archaeological materials. It is shown that the knowledge which is gained from the use of a combination of classical radiological methods and computed tomography cannot be enhanced by an autopsy of the study objects. Since because of this the objects can be kept in their original condition, a later checking of the results is guaranteed with the possibility of clearing up remaining open questions by means of further developed methods. (orig.) [de
Radiological analyses of France Telecom surge arresters. Study performed for the CGT FAPT Cantal
International Nuclear Information System (INIS)
2010-02-01
This document reports the radiological characterization of various versions of surge arresters used in the past to protect telephone lines against over-voltages. These equipment, which use various radioactive materials, were assessed by gamma radiation flow measurements, alpha-beta-gamma count rate measurements, dose rate measurements, gamma spectrometry analyses, tritium emanation test, radon 222 emanation test, smearing. Recommendations are formulated to manage radioactive surge arresters which are still being operated
International Nuclear Information System (INIS)
Ed, D.; Chu, L.; Chepulis, P.; Hamel, M.
1986-01-01
The State of Illinois, Department of Nuclear Safety, has decontaminated and decommissioned the defunct Luminous Processes, Inc. facility located in Ottawa, Illinois. The state's overall experience throughout the project is generally described, with particular emphasis given to the radiological characterization (Ra-226+progeny and H-3) and subsequent segregation and disposal of building materials as either radioactive or non-radioactive. Experiences involving direct application of health physics principles (criteria selection, sampling schemes, analytical techniques, data reduction, quality assurance) are discussed. Experiences involving other health physics regimens (personnel protection and dosimetry, environmental monitoring) as well as social sciences and economic considerations (public perception, media relations, political involvement, contractor interactions, fiscal management) are discussed only insofar as they affect the radiological characterization, segregation and disposal processes
Radiological control technician: Training program management manual
International Nuclear Information System (INIS)
1992-10-01
This manual defines and describes the DOE Radiological Control Technician Core Training Program qualification and training process, material development requirements, standards and policies, and administration. The manual applies to Radiological Control Technician Training Programs at all DOE contractor sites
Radiological health training resources, 1975
International Nuclear Information System (INIS)
1975-01-01
The Division of Training and Medical Applications is the component of the Bureau of Radiological Health which has the responsibility for providing training assistance to the Nation's radiological health agencies. Recognizing that these agencies are establishing their own user and personnel training programs, the Division offers through the Training Resources Center a variety of educational materials which may be utilized for specific training purposes. This bulletin contains a list of educational materials, including publications, booklets, slides and transparencies, movies, video tapes, training guides, and training seminars for the education of x-ray technicians in radiation protection
Radiological terrorism and Australia's response
International Nuclear Information System (INIS)
Patterson, D.
2003-01-01
A terrorist attack in Australia involving dispersal of radioactive material is different from conventional terrorist attacks involving explosives. The trauma experienced by victims during an explosive incident includes cuts, broken limbs, burns and shock. When an explosive device involving radioactive materials is involved, there are a number of additional characteristics including the contamination of victims and the surrounding area and the potential requirement for ongoing monitoring and decontamination. Response actions may require additional complex emergency response measures including immediate protective actions to protect those potentially exposed to contamination, mass casualty care, and public and mental health. There are concerns that terrorist organizations are showing increasing interest in acquiring radiological material that could be used with explosive. A dirty bomb or technically known as a radiological dispersal device (RDD) is a device designed to spread radioactive contamination over a wide area and pose a health and safety threat to those within the contaminated area. The radioactive material could be in the form of a large chunk of material, fine powder, a liquid mist, or a gas. The material may also be spread in other ways, such as by simply emptying a container over the desired area. As RDD's do not require large amounts of explosives, there is unlikely to be a large numbers of casualties, however the areas contaminated by the radiological material may cause immediate and long term health risks to those exposed. An RDD is a weapon of Mass Disruption rather than destruction. While the likelihood of RDD's being employed by terrorist in Australia is still considered remote, Australia's emergency response organizations are developing plans to ensure a rapid and comprehensive response occurs should such an event occur in this country, The presentation will outline Australia's response arrangements at the local/state level and the type of federal
International Nuclear Information System (INIS)
Zeevaert, T.
1998-01-01
Radiological optimization is one of the basic principles in each radiation-protection system and it is a basic requirement in the safety standards for radiation protection in the European Communities. The objectives of the research, performed in this field at the Belgian Nuclear Research Centre SCK-CEN, are: (1) to implement the ALARA principles in activities with radiological consequences; (2) to develop methodologies for optimization techniques in decision-aiding; (3) to optimize radiological assessment models by validation and intercomparison; (4) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (5) to develop methods and programmes to assist decision-makers during a nuclear emergency; (6) to support the policy of radioactive waste management authorities in the field of radiation protection; (7) to investigate existing software programmes in the domain of multi criteria analysis. The main achievements for 1997 are given
Radiological control criteria for materials considered for recycle and reuse
International Nuclear Information System (INIS)
Kennedy, W.E. Jr.; Hill, R.L.; Aaberg, R.L.; Wallo, A. III.
1995-01-01
Pacific Northwest Laboratory (PNL) is conducting technical analyses to support the U.S. Department of Energy (DOE), Office of Environmental Guidance, Air, Water, and Radiation Division (DOE/EH-232) in developing radiological control criteria for recycling or reuse of metals or equipment containing residual radioactive contamination from DOE operations. The criteria, framed as acceptable concentrations for release of materials for recycling or reuse, are risk-based and were developed through analysis of generic radiation exposure scenarios and pathways. The analysis includes evaluation of relevant radionuclides, potential mechanisms of exposure, and non-health-related impacts of residual radioactivity on electronics and film. The analysis considers 42 key radionuclides that DOE operations are known to generate and that may be contained in recycled or reused metals or equipment. The preliminary results are compared with similar results reported by the International Atomic Energy Agency, by radionuclide grouping. (author)
Assessment of radiological hazards of naturally occurring radioactive materials in cement industry
International Nuclear Information System (INIS)
Aslam, M.; Gul, R.; Ara, T.; Hussain, M.
2012-01-01
A study on the radiological hazard in Portland cement due to the presence of naturally occurring radioactive materials is being carried out. The Portland cement manufactured in the Islamabad/Rawalpindi region of Pakistan, intermediate products (clinker) and the various raw materials which compose the product have been analysed for 226 Ra, 232 Th and 40 K using a gamma spectrometry system with a N-type high-purity germanium detector of 80 % relative efficiency. From the measured gamma ray spectra, specific activities were determined. The mean values of the total specific activity of 226 Ra, 232 Th and 40 K are 34.2±11.9, 29.1±3.6 and 295.1±66.9 Bq kg -1 , respectively in Portland cement, 28.4±8.7, 11.3±1.7 and 63.1±17.3 Bq kg -1 , respectively in lime stone, 8.2±1.9, 16.2±3.9 and 187.7±53.2 Bq kg -1 , respectively in gypsum, 34.7±13.1, 41.2±6.7 and 187.6±17.2 Bq kg -1 , respectively in clay, 41.1±11.8, 39.3±6.9 and 195.1±29.2 Bq kg -1 , respectively in laterite and 51.1±18.2, 23.2±1.2 and 258.4±15.3 Bq kg -1 , respectively in clinker. The radium equivalent activities (Ra eq ), external hazard index (H ex ), internal hazard index (H in ), absorbed dose rate in air (D) and annual effective dose rate (E eff ) were also determined. The measured activity concentrations for these radio nuclides and radiological indices were compared with the reported national and international data. All these measured values are comparable with the worldwide data reported in UNSCEAR publications. (authors)
Remote inspection with multi-copters, radiological sensors and SLAM techniques
Carvalho, Henrique; Vale, Alberto; Marques, Rúben; Ventura, Rodrigo; Brouwer, Yoeri; Gonçalves, Bruno
2018-01-01
Activated material can be found in different scenarios, such as in nuclear reactor facilities or medical facilities (e.g. in positron emission tomography commonly known as PET scanning). In addition, there are unexpected scenarios resulting from possible accidents, or where dangerous material is hidden for terrorism attacks using nuclear weapons. Thus, a technological solution is important to cope with fast and reliable remote inspection. The multi-copter is a common type of Unmanned Aerial Vehicle (UAV) that provides the ability to perform a first radiological inspection in the described scenarios. The paper proposes a solution with a multi-copter equipped with on-board sensors to perform a 3D reconstruction and a radiological mapping of the scenario. A depth camera and a Geiger-Müler counter are the used sensors. The inspection is performed in two steps: i) a 3D reconstruction of the environment and ii) radiation activity inference to localise and quantify sources of radiation. Experimental results were achieved with real 3D data and simulated radiation activity. Experimental tests with real sources of radiation are planned in the next iteration of the work.
Remote inspection with multi-copters, radiological sensors and SLAM techniques
Directory of Open Access Journals (Sweden)
Carvalho Henrique
2018-01-01
Full Text Available Activated material can be found in different scenarios, such as in nuclear reactor facilities or medical facilities (e.g. in positron emission tomography commonly known as PET scanning. In addition, there are unexpected scenarios resulting from possible accidents, or where dangerous material is hidden for terrorism attacks using nuclear weapons. Thus, a technological solution is important to cope with fast and reliable remote inspection. The multi-copter is a common type of Unmanned Aerial Vehicle (UAV that provides the ability to perform a first radiological inspection in the described scenarios. The paper proposes a solution with a multi-copter equipped with on-board sensors to perform a 3D reconstruction and a radiological mapping of the scenario. A depth camera and a Geiger-Müler counter are the used sensors. The inspection is performed in two steps: i a 3D reconstruction of the environment and ii radiation activity inference to localise and quantify sources of radiation. Experimental results were achieved with real 3D data and simulated radiation activity. Experimental tests with real sources of radiation are planned in the next iteration of the work.
International Nuclear Information System (INIS)
Reavis, R.
1996-03-01
The INEL Radiological Control Performance Indicator Report is comprised of a description of the indicator and the criteria used for measurement. Indicators evaluated in this report include: collective radiation dose; average worker radiation dose; maximum radiation dose to a worker; maximum neutron dose to a worker; number of skin contaminations; number of clothing contaminations; airborne events; total radiological intakes; contamination areas; high contamination area; airborne radioactivity area; and radioactive spills
White Paper: Curriculum in Interventional Radiology.
Mahnken, Andreas H; Bücker, Arno; Hohl, Christian; Berlis, Ansgar
2017-04-01
Purpose Scope and clinical importance of interventional radiology markedly evolved over the last decades. Consequently it was acknowledged as independent subspecialty by the "European Union of Medical Specialists" (UEMS). Based on radiological imaging techniques Interventional Radiology is an integral part of Radiology. Materials und Methods In 2009 the German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a structured training in Interventional Radiology. In cooperation with the German Society of Neuroradiology (DGNR) this training was extended to also cover Interventional Neuroradiology in 2012. Tailored for this training in Interventional Radiology a structured curriculum was developed, covering the scope of this modular training. Results The curriculum is based on the DeGIR/DGNR modular training concept in Interventional Radiology. There is also an European Curriculum and Syllabus for Interventional Radiology developed by the "Cardiovascular and Interventional Radiological Society of Europe" (CIRSE). The presented curriculum in Interventional Radiology is designed to provide a uniform base for the training in Interventional Radiology in Germany, based on the competencies obtained during residency. Conclusion This curriculum can be used as a basis for training in Interventional Radiology by all training sites. Key Points: · Interventional Radiology is an integral part of clinical radiology. · The German Society for Interventional Radiology and minimally-invasive therapy (DeGIR) developed a curriculum in Interventional Radiology. · This curriculum is an integrative basis for the training in interventional. Citation Format · Mahnken AH, Bücker A, Hohl C et al. White Paper: Curriculum in Interventional Radiology. Fortschr Röntgenstr 2017; 189: 309 - 311. © Georg Thieme Verlag KG Stuttgart · New York.
Machine Learning and Radiology
Wang, Shijun; Summers, Ronald M.
2012-01-01
In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. PMID:22465077
Radiologic placement of Hickman catheters
International Nuclear Information System (INIS)
Robertson, L.J.; Mauro, M.A.; Jaques, P.F.
1988-01-01
Hickman catheter inserter has previously been predominantly accomplished surgically by means of venous cutdown or percutaneous placement in the operating room. The authors describe their method and results for 55 consecutive percutaneous placements of Hickman catheters in the interventional radiology suite. Complication rates were comparable to those for surgical techniques. Radiologic placement resulted in increased convenience, decreased time and cost of insertion, and super fluoroscopic control of catheter placement and any special manipulations. Modern angiographic materials provide safer access to the subclavian vein than traditional methods. The authors conclude that radiologic placement of Hickman catheters offers significant advantages over traditional surgical placement
An Advanced Radiological Survey and Mapping System
International Nuclear Information System (INIS)
McCown, J.; Rogers, D.; Waggoner, Ch.
2009-01-01
A variety of radiological surveying systems have been described in the literature. This paper describes relative performances of a system that can employ a variety of radiological sensors including NaI, LiI, and LaBr 3 units of various sizes. The system includes navigation and data collection software that facilitates surveying without the use of survey grid-lines. Parameters presented to the operator via a graphical user interface (GUI) for monitoring system performance and navigation are described. Radiological spectra are logged along with position data from three differential GPS sensors to enhance position accuracy by taking into account the pitch and roll as the survey vehicle moves over uneven terrain. Accuracy of position data increases the potential for, and value of, data fusion with other survey data such as electromagnetic induction images. The survey system described has been developed around a zero turn radius lawn mower equipped with on-board generator/inverter for powering electronic and data communication equipment to maximize surveying effectiveness. Detection limits for U-238 will be discussed for the NaI (FIDLER, 75x75 mm, and 100x100x400 mm) and LaBr 3 (75x75 mm) detectors. These parameters will be reported for a variety of survey speeds (stationary, 1, 2, and 3 m/s), with and without the use of advanced signal processing to increase detection sensitivity. A background subtraction algorithm evaluating each spectrum for the presence of naturally occurring radiological materials will also be described for correcting each datum prior to mapping using Geosoft Oasis montaj. (authors)
IAEA Perspectives on Radiological Characterisation
International Nuclear Information System (INIS)
O'Sullivan, Patrick; Ljubenov, Vladan
2012-01-01
Requirements for characterization of radiological and other hazards in nuclear facilities are reflected in the IAEA Safety Standards. WS-R-5, Safety Requirements for Decommissioning of Facilities using Radioactive Material, includes a requirement that 'During the preparation of the final decommissioning plan, the extent and type of radioactive material (irradiated and contaminated structures and components) at the facility shall be determined by means of a detailed characterization survey and on the basis of records collected during the operational period'. The subsidiary Safety Guide WS-G-2.1, Decommissioning of Nuclear Power Plants and Research Reactors, further elaborates that 'A survey of radiological and non-radiological hazards provides an important input for the safety assessment and for implementing a safe approach during the work'. Although the characterisation requirements addressed in the Safety Standards relate primarily to the detailed survey activities undertaken following the shutdown of the facility, it is evident that radiological characterization is of relevance to all major phases of the lifetime of a nuclear facility, including: - the siting phase - baseline surveys are undertaken to determine background radiation levels; - the construction phase - construction materials are retained to support future calculations of radioactivity distributions; - the operational phase - surveys are done regularly, with additional surveys being required following incidents involving plant contamination; - the transition phase - detailed radiological surveys are required to support the development of the final decommissioning plan; and - the closure phase - a final survey of the site and any remaining structures will be needed to support an application for release of the site from regulatory control. In the case of facilities that are already shut down, the main purpose of radiological characterisation is to provide a reliable database of information on the
Energy Technology Data Exchange (ETDEWEB)
Ortiz, J.; Ballesteros, L.; Gallardo, S.; Martorell, S.
2014-07-01
In this presentation, radiological characterization is done by gamma spectrometry various types of ceramic tiles and use as building material in relation to the potential radiological risk deriving from this use are discussed. The discussion includes both the rules of the countries being targeted as the new basic security policy (BSS) issued by the EU 2014. (Author)
Research and development in radiological protection
International Nuclear Information System (INIS)
Butragueno, J. L.; Villota, C.; Gutierrez, C.; Rodriguez, A.
2004-01-01
The objective of Radiological Protection is to guarantee that neither people, be they workers or members of the public, or the environment are exposed to radiological risks considered by society to be unacceptable. Among the various resources available to meet this objective is Research and Development (R and D), which is carried out in three areas: I. Radiological protection of persons: (a) knowledge of the biological effects of radiations, in order to determine the relationship that exists between radiation exposure dose and its effects on health; (b) the development of new personal dosimetry techniques in order to adapt to new situations, instrumental techniques and information management technologies allowing for better assessment of exposure dose; and (c) development of the principle of radiological protection optimisation (ALARA), which has been set up internationally as the fundamental principle on which radiological protection interventions are based. II. Assessment of environmental radiological impact, the objective of which is to assess the nature and magnitude of situations of exposure to ionising radiations as a result of the controlled or uncontrolled release of radioactive material to the environment, and III.Reduction of the radiological impact of radioactive wastes, the objective of which is to develop radioactive material and waste management techniques suitable for each situation, in order to reduce the risks associated with their definitive management or their release to the environment. Briefly described below are the strategic lines of R and D of the CSN, the Electricity Industry, Ciemat and Enresa in the aforementioned areas. (Author)
Radiation protection and quality assurance in dental radiology: II. Panoramic radiology
International Nuclear Information System (INIS)
Jodar-Porlan, S.; Alcaraz, M.; Martinez-Beneyto, Y.; Saura-Iniesta, A.M.; Velasco-Hidalgo, E.
2001-01-01
This paper studies 278 official reports on quality assurance in dental radiology in the context of the first revision of these dental clinics, as a result of the entry into force of the regulations establishing the duties for these types of facilities. In the results section we present a quantitative analysis of the facilities equipped with an panoramic radiology apparatus, making a special reference to the brands they have available, as well as their physical features (kV, mA, filtration) and the deviations detected in their operation. Some of their features in the process of obtaining radiological images at those facilities (film control, development time, liquid renewal) are determined, and the average dose of ionising radiation used in order to obtain the same tooth radiological image is presented. This paper shows, in a quantitative way, the characteristic features of panoramic radiology in our medium. The study is intended to be continued during the next years, which would allow the assessment of the prospective improvement in dental radiological performances as a result of the newly established regulations. (author)
Bavarnegin, Elham; Moghaddam, Masoud Vahabi; Fathabadi, Nasrin
2013-04-01
Building materials, collected from different sites in Ramsar, a northern coastal city in Iran, were analyzed for their natural radionuclide contents. The measurements were carried out using a high resolution high purity Germanium (HPGe) gamma-ray spectrometer system. The activity concentration of (226)Ra, (232)Th, and (40)K content varied from below the minimum detection limit up to 86,400 Bqkg(-1), 187 Bqkg(-1), and 1350 Bqkg(-1), respectively. The radiological hazards incurred from the use of these building materials were estimated through various radiation hazard indices. The result of this survey shows that values obtained for some samples are more than the internationally accepted maximum limits and as such, the use of them as a building material pose significant radiation hazard to individuals.
Research on photoconductor radiological sensors
International Nuclear Information System (INIS)
Beaumont, Francois
1989-01-01
Because of the evolution of medical imaging techniques to digital systems, it is necessary to replace radiological film which has many drawbacks, by a detector quite as efficient and quickly giving a digitable signal. The purpose of this thesis is to find new X-ray digital imaging processes using photoconductor materials such as amorphous selenium. After reviewing the principle of direct radiology and functions to be served by the X-ray sensor (i e. detection, memory, assignment, visualization), we explain specification. We especially show the constraints due to the object to be radio-graphed (condition of minimal exposure), and to the reading signal (electronic noise detection associated with a reading frequency). As a result of this study, a first photoconductor sensor could be designed. Its principle is based on photo carrier trapping at dielectric-photoconductor structure interface. The reading system needs the scanning of a laser beam upon the sensor surface. The dielectric-photoconductor structure enabled us to estimate the possibilities offered by the sensor and to build a complete x-ray imaging system. The originality of thermos-dielectric sensor, that was next studied, is to allow a thermal assignment reading. The chosen system consists in varying the ferroelectric polymer capacity whose dielectric permittivity is weak at room temperature. The thermo-dielectric material was studied by thermal or Joule effect stimulation. During our experiments, trapping was found in a sensor made of amorphous selenium between two electrodes. This new effect was performed and enabled us to expose a first interpretation. Eventually, the comparison of these new sensor concepts with radiological film shows the advantage of the proposed solution. (author) [fr
International Nuclear Information System (INIS)
Mueller, P.G.
2000-01-01
During the 1960's and 70's the expanded use of nuclear materials to generate electricity, to provide medical benefits, and for research purposes continued to grow in the United States. While substantial effort went into constructing plants and facilities and providing for a number of redundant backup systems for safety purposes, little effort went into the development of emergency response plans for possible major radiological accidents. Unfortunately, adequate plans and procedures had not been developed to co-ordinate either state or federal emergency response assets and personnel should a major radiological accident occur. This situation became quite evident following the Three Mile Island Nuclear Reactor accident in 1979. An accident of that magnitude had not been adequately prepared for and Pennsylvania's limited emergency radiological resources and capabilities were quickly exhausted. Several federal agencies with statutory responsibilities for emergency response, including the U.S. Environmental Protection Agency (EPA), U.S. Department of Energy (DOE), Federal Emergency Management Agency (FEMA), Nuclear Regulatory Commission (NRC), and others provided extensive assistance and support during the accident. However, the assistance was not fully co-ordinated nor controlled. Following the Three Mile Island incident 13 federal agencies worked co-operatively to develop an agreement called the Federal Radiological Emergency Response Plan (FRERP). Signed in November 1985, this plan delineated the statutory responsibilities and authorities of each federal agency signatory to the FRERP. In the event of a major radiological accident, the FRERP would be activated to ensure that a co-ordinated federal emergency response would be available to respond to any major radiological accident scenario. The FRERP encompasses a wide variety of radiological accidents, not just those stemming from nuclear power plants. Activation of the FRERP could occur from major accidents involving
Nevada National Security Site Radiological Control Manual
International Nuclear Information System (INIS)
2012-01-01
This document supersedes DOE/NV/25946--801, 'Nevada Test Site Radiological Control Manual,' Revision 1 issued in February 2010. Brief Description of Revision: A complete revision to reflect a recent change in name for the NTS; changes in name for some tenant organizations; and to update references to current DOE policies, orders, and guidance documents. Article 237.2 was deleted. Appendix 3B was updated. Article 411.2 was modified. Article 422 was re-written to reflect the wording of DOE O 458.1. Article 431.6.d was modified. The glossary was updated. This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE) and the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection.' Programs covered by this manual are located at the Nevada National Security Site (NNSS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Livermore, California; and Andrews Air Force Base, Maryland. In addition, fieldwork by NNSA/NSO at other locations is covered by this manual. Current activities at NNSS include operating low-level radioactive and mixed waste disposal facilities for United States defense-generated waste, assembly and execution of subcritical experiments, assembly/disassembly of special experiments, the storage and use of special nuclear materials, performing criticality experiments, emergency responder training, surface cleanup and site characterization of contaminated land areas, environmental activity by the University system, and nonnuclear test operations, such as controlled spills of hazardous materials at the Hazardous Materials Spill Center. Currently, the major potential for occupational radiation exposure is associated with the burial of
Nevada National Security Site Radiological Control Manual
Energy Technology Data Exchange (ETDEWEB)
Radiological Control Managers’ Council
2012-03-26
This document supersedes DOE/NV/25946--801, 'Nevada Test Site Radiological Control Manual,' Revision 1 issued in February 2010. Brief Description of Revision: A complete revision to reflect a recent change in name for the NTS; changes in name for some tenant organizations; and to update references to current DOE policies, orders, and guidance documents. Article 237.2 was deleted. Appendix 3B was updated. Article 411.2 was modified. Article 422 was re-written to reflect the wording of DOE O 458.1. Article 431.6.d was modified. The glossary was updated. This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE) and the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection.' Programs covered by this manual are located at the Nevada National Security Site (NNSS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Livermore, California; and Andrews Air Force Base, Maryland. In addition, fieldwork by NNSA/NSO at other locations is covered by this manual. Current activities at NNSS include operating low-level radioactive and mixed waste disposal facilities for United States defense-generated waste, assembly and execution of subcritical experiments, assembly/disassembly of special experiments, the storage and use of special nuclear materials, performing criticality experiments, emergency responder training, surface cleanup and site characterization of contaminated land areas, environmental activity by the University system, and nonnuclear test operations, such as controlled spills of hazardous materials at the Hazardous Materials Spill Center. Currently, the major potential for occupational radiation exposure is associated with the burial of
Radiology findings in adult patients with vocal fold paralysis
Energy Technology Data Exchange (ETDEWEB)
Robinson, S. [Helsinki Medical Imaging Centre, University of Helsinki, Haartmaninkatu, Helsinki (Finland)]. E-mail: s.robinson@dzu.at; Pitkaeranta, A. [Department of Otorhinolaryngology, Haartmaninkatu, Helsinki (Finland)
2006-10-15
Aim: To compile imaging findings in patients with vocal fold paralysis. Materials and methods: A retrospective analysis of the medical charts of 100 consecutive patients, admitted to our department with vocal fold paralysis was undertaken. After laryngoscopy, patients were referred for radiological work-up depending on their clinical history and clinical findings. Ultrasound of the neck and/or contrast-enhanced spiral computed tomography (CT) of the neck and mediastinum was performed, extending to include the whole chest if necessary. In one patient, CT of the brain and in two patients, magnetic resonance angiography was undertaken. Analysis of the clinical and radiological data was performed to assess the most frequent causes for vocal fold paralysis. Results: In 66% of patients, the paralysis was related to previous surgery. Thirty-four percent of cases were labelled idiopathic after clinical examination. After imaging and follow-up, only 8% remained unexplained. Nine patients suffered from neoplasms, four from vascular disease, and 12 from infections. One patient developed encephalomyelitis disseminata on follow-up. Conclusion: Thorough radiological work-up helps to reduce the amount of idiopathic cases of vocal fold paralysis and guides appropriate therapy.
Radiology findings in adult patients with vocal fold paralysis
International Nuclear Information System (INIS)
Robinson, S.; Pitkaeranta, A.
2006-01-01
Aim: To compile imaging findings in patients with vocal fold paralysis. Materials and methods: A retrospective analysis of the medical charts of 100 consecutive patients, admitted to our department with vocal fold paralysis was undertaken. After laryngoscopy, patients were referred for radiological work-up depending on their clinical history and clinical findings. Ultrasound of the neck and/or contrast-enhanced spiral computed tomography (CT) of the neck and mediastinum was performed, extending to include the whole chest if necessary. In one patient, CT of the brain and in two patients, magnetic resonance angiography was undertaken. Analysis of the clinical and radiological data was performed to assess the most frequent causes for vocal fold paralysis. Results: In 66% of patients, the paralysis was related to previous surgery. Thirty-four percent of cases were labelled idiopathic after clinical examination. After imaging and follow-up, only 8% remained unexplained. Nine patients suffered from neoplasms, four from vascular disease, and 12 from infections. One patient developed encephalomyelitis disseminata on follow-up. Conclusion: Thorough radiological work-up helps to reduce the amount of idiopathic cases of vocal fold paralysis and guides appropriate therapy
Quality Control Assessment of Radiology Devices in Kerman Province, Iran
Zahra Jomehzadeh; Ali Jomehzadeh; Mohammad Bagher Tavakoli
2016-01-01
Introduction Application of quality control (QC) programs at diagnostic radiology departments is of great significance for optimization of image quality and reduction of patient dose. The main objective of this study was to perform QC tests on stationary radiographic X-ray machines, installed in 14 hospitals of Kerman province, Iran. Materials and Methods In this cross-sectional study, QC tests were performed on 28 conventional radiographic X-ray units in Kerman governmental hospitals, based ...
Radiology education: a radiology curriculum for all medical students?
Zwaan, Laura; Kok, Ellen M; van der Gijp, Anouk
2017-09-26
Diagnostic errors in radiology are frequent and can cause severe patient harm. Despite large performance differences between radiologists and non-radiology physicians, the latter often interpret medical images because electronic health records make images available throughout the hospital. Some people argue that non-radiologists should not diagnose medical images at all, and that medical school should focus on teaching ordering skills instead of image interpretation skills. We agree that teaching ordering skills is crucial as most physicians will need to order medical images in their professional life. However, we argue that the availability of medical images is so ubiquitous that it is important that non-radiologists are also trained in the basics of medical image interpretation and, additionally in recognizing when radiological consultancy should be sought. In acute situations, basic image interpretations skills can be life-saving. We plead for a radiology curriculum for all medical students. This should include the interpretation of common abnormalities on chest and skeletal radiographs and a basic distinction of normal from abnormal images. Furthermore, substantial attention should be given to the correct ordering of radiological images. Finally, it is critical that students are trained in deciding when to consult a radiologist.
The radiological impact of the normal rail transport of radioactive materials in the United Kingdom
International Nuclear Information System (INIS)
Mairs, J.H.
1983-01-01
Recently the NRPB, under contract to the Health and Safety Executive, and in association with the British Railways Board, has assessed the radiological impact of consignments transported on the British Rail system. The work has shown the radiation exposure of British Rail staff and of the public to be low. This paper identifies the types of radioactive materials transported by rail, outlines the methods used to assess the doses to persons exposed and presents the results of these assessments. (author)
International Nuclear Information System (INIS)
Lee, Young Han
2012-01-01
Purpose: The objectives are (1) to introduce an easy open-source macro program as connection software and (2) to illustrate the practical usages in radiologic reading environment by simulating the radiologic reading process. Materials and methods: The simulation is a set of radiologic reading process to do a practical task in the radiologic reading room. The principal processes are: (1) to view radiologic images on the Picture Archiving and Communicating System (PACS), (2) to connect the HIS/EMR (Hospital Information System/Electronic Medical Record) system, (3) to make an automatic radiologic reporting system, and (4) to record and recall information of interesting cases. This simulation environment was designed by using open-source macro program as connection software. Results: The simulation performed well on the Window-based PACS workstation. Radiologists practiced the steps of the simulation comfortably by utilizing the macro-powered radiologic environment. This macro program could automate several manual cumbersome steps in the radiologic reading process. This program successfully acts as connection software for the PACS software, EMR/HIS, spreadsheet, and other various input devices in the radiologic reading environment. Conclusion: A user-friendly efficient radiologic reading environment could be established by utilizing open-source macro program as connection software.
Machine learning and radiology.
Wang, Shijun; Summers, Ronald M
2012-07-01
In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. Copyright © 2012. Published by Elsevier B.V.
Non-Destructive Radiological Characterisation Of Contaminated And Activated Concrete
International Nuclear Information System (INIS)
Cantrel, E.
2005-01-01
The decommissioning of nuclear facilities leads to large quantities of concrete and building material wastes. Radioactivity in building structures arise from very different physical processes such as neutron activation (bioshield), diffusion of the contaminants in the material (primary coolant leakage, maintenance and fuel loading) or aerosol deposition. The variety of the building material also extends the range of faced radiological characteristics. Therefore the minimization of concrete waste generation requires extensive characterisations and the availability of different measurement tools and methods. Up to now, these measurements came from the coring and the radiological analysis of the concrete, which is a destructive, long and costly technique. Looking for alternative solutions, SCK-CEN has started to investigate in collaboration with EDF -research and development and CEA (France) several non destructive methods based on gamma spectroscopy and different spectral examinations using mathematical calibration and modelling tools available on the market. Information on in-depth activity distribution can be derived from in situ gamma spectra by modelling absorption laws (peak to peak ratios) and photons interactions (Compton front) in the bulk of the concrete. As they combine modelling and measurement, the different methodologies being evaluated involve a lot of uncertainty sources linked to the measurement environment, to the knowledge available on site (historical background, material composition), to the operator responsible for the data acquisition and to the performance of the equipment. Therefore a detailed sensitivity analysis is required to define the range of applicability and the performances of the different methods
Guidelines for a radiology department
International Nuclear Information System (INIS)
1981-05-01
This manual presents guidelines for hospitals on a radiology quality assurance and dose measurement audit program and a system of planned actions that monitor and record the performance and effectiveness of the radiological service
International Nuclear Information System (INIS)
Lopez, Felix A.; Gazquez, Manuel; Alguacil, Francisco Jose; Bolivar, Juan Pedro; Garcia-Diaz, Irene; Lopez-Coto, Israel
2011-01-01
Highlights: → Microencapsulation of phosphogypsum residues into a sulfur polymer matrix. → Inertization of a waste material. → Radiological characterization of the as built new material (phosphogypsum plus sulfur polymer matrix). - Abstract: The aim of this work is to prepare a new type of phosphogypsum-sulfur polymer cements (PG-SPC) to be utilised in the manufacture of building materials. Physico-chemical and radiological characterization was performed in phosphogypsum and phosphogypsum-sulfur polymer concretes and modeling of exhalation rates has been also carried out. An optimized mixture of the materials was obtained, the solidified material with optimal mixture (sulfur/phosphogypsum = 1:0.9, phosphogypsum dosage = 10-40 wt.%) results in highest strength (54-62 MPa) and low total porosity (2.8-6.8%). The activity concentration index (I) in the PG-SPC is lower than the reference value in the most international regulations and; therefore, these cements can be used without radiological restrictions in the manufacture of building materials. Under normal conditions of ventilation, the contribution to the expected radon indoor concentration in a standard room is below the international recommendations, so the building materials studied in this work can be applied to houses built up under normal ventilation conditions. Additionally, and taking into account that the PG is enriched in several natural radionuclides as 226 Ra, the leaching experiments have demonstrated that environmental impact of the using of SPCs cements with PG is negligible.
Energy Technology Data Exchange (ETDEWEB)
Lopez, Felix A., E-mail: flopez@cenim.csic.es [Centro Nacional de Investigaciones Metalurgicas (CENIM), CSIC, Avda. Gregorio del Amo, 8, 28040 Madrid (Spain); Gazquez, Manuel [Departamento de Fisica Aplicada, Universidad de Huelva, Campus de El Carmen, 21071 Huelva (Spain); Alguacil, Francisco Jose [Centro Nacional de Investigaciones Metalurgicas (CENIM), CSIC, Avda. Gregorio del Amo, 8, 28040 Madrid (Spain); Bolivar, Juan Pedro [Departamento de Fisica Aplicada, Universidad de Huelva, Campus de El Carmen, 21071 Huelva (Spain); Garcia-Diaz, Irene [Centro Nacional de Investigaciones Metalurgicas (CENIM), CSIC, Avda. Gregorio del Amo, 8, 28040 Madrid (Spain); Lopez-Coto, Israel [Departamento de Fisica Aplicada, Universidad de Huelva, Campus de El Carmen, 21071 Huelva (Spain)
2011-08-15
Highlights: {yields} Microencapsulation of phosphogypsum residues into a sulfur polymer matrix. {yields} Inertization of a waste material. {yields} Radiological characterization of the as built new material (phosphogypsum plus sulfur polymer matrix). - Abstract: The aim of this work is to prepare a new type of phosphogypsum-sulfur polymer cements (PG-SPC) to be utilised in the manufacture of building materials. Physico-chemical and radiological characterization was performed in phosphogypsum and phosphogypsum-sulfur polymer concretes and modeling of exhalation rates has been also carried out. An optimized mixture of the materials was obtained, the solidified material with optimal mixture (sulfur/phosphogypsum = 1:0.9, phosphogypsum dosage = 10-40 wt.%) results in highest strength (54-62 MPa) and low total porosity (2.8-6.8%). The activity concentration index (I) in the PG-SPC is lower than the reference value in the most international regulations and; therefore, these cements can be used without radiological restrictions in the manufacture of building materials. Under normal conditions of ventilation, the contribution to the expected radon indoor concentration in a standard room is below the international recommendations, so the building materials studied in this work can be applied to houses built up under normal ventilation conditions. Additionally, and taking into account that the PG is enriched in several natural radionuclides as {sup 226}Ra, the leaching experiments have demonstrated that environmental impact of the using of SPCs cements with PG is negligible.
Rosenkrantz, Andrew B; Lawson, Kirk; Ally, Rosina; Chen, David; Donno, Frank; Rittberg, Steven; Rodriguez, Joan; Recht, Michael P
2015-01-01
To evaluate sustainability of impact of rapid, focused process improvement (PI) events on process and performance within an academic radiology department. Our department conducted PI during 2011 and 2012 in CT, MRI, ultrasound, breast imaging, and research billing. PI entailed participation by all stakeholders, facilitation by the department chair, collection of baseline data, meetings during several weeks, definition of performance metrics, creation of an improvement plan, and prompt implementation. We explore common themes among PI events regarding initial impact and durability of changes. We also assess performance in each area pre-PI, immediately post-PI, and at the time of the current study. All PI events achieved an immediate improvement in performance metrics, often entailing both examination volumes and on-time performance. IT-based solutions, process standardization, and redefinition of staff responsibilities were often central in these changes, and participants consistently expressed improved internal leadership and problem-solving ability. Major environmental changes commonly occurred after PI, including a natural disaster with equipment loss, a change in location or services offered, and new enterprise-wide electronic medical record system incorporating new billing and radiology informatics systems, requiring flexibility in the PI implementation plan. Only one PI team conducted regular post-PI follow-up meetings. Sustained improvement was frequently, but not universally, observed: in the long-term following initial PI, measures of examination volume showed continued progressive improvements, whereas measures of operational efficiency remained stable or occasionally declined. Focused PI is generally effective in achieving performance improvement, although a changing environment influences the sustainability of impact. Thus, continued process evaluation and ongoing workflow modifications are warranted. Copyright © 2015 American College of Radiology
Do, Bao H; Wu, Andrew; Biswal, Sandip; Kamaya, Aya; Rubin, Daniel L
2010-11-01
Storing and retrieving radiology cases is an important activity for education and clinical research, but this process can be time-consuming. In the process of structuring reports and images into organized teaching files, incidental pathologic conditions not pertinent to the primary teaching point can be omitted, as when a user saves images of an aortic dissection case but disregards the incidental osteoid osteoma. An alternate strategy for identifying teaching cases is text search of reports in radiology information systems (RIS), but retrieved reports are unstructured, teaching-related content is not highlighted, and patient identifying information is not removed. Furthermore, searching unstructured reports requires sophisticated retrieval methods to achieve useful results. An open-source, RadLex(®)-compatible teaching file solution called RADTF, which uses natural language processing (NLP) methods to process radiology reports, was developed to create a searchable teaching resource from the RIS and the picture archiving and communication system (PACS). The NLP system extracts and de-identifies teaching-relevant statements from full reports to generate a stand-alone database, thus converting existing RIS archives into an on-demand source of teaching material. Using RADTF, the authors generated a semantic search-enabled, Web-based radiology archive containing over 700,000 cases with millions of images. RADTF combines a compact representation of the teaching-relevant content in radiology reports and a versatile search engine with the scale of the entire RIS-PACS collection of case material. ©RSNA, 2010
International Nuclear Information System (INIS)
Morton, J. R.
2000-01-01
From the 1950s, the Vance Road laboratory was the site of extensive nuclear medical research and involved the used of numerous radionuclides. These nuclides were stored in a source vault stored on the first floor of the facility. Nuclear medical research is no longer conducted in this facility, and the source vault was remediated in preparation for converting the area to office space and general use. The Environmental Survey and Site Assessment Program (ESSAP) of ORISE performed a radiological assessment survey of the source vault and its associated miscellaneous building materials and laboratory equipment in preparation for the conversion to general use space
Talanow, Roland
2010-01-01
This article focuses on Radiology Olympics (www.RadiologyOlympics.com) - a collaboration with the international Radiology community for Radiology education, Radiolopolis (www.Radiolopolis.com). The Radiology Olympics honour the movers and shakers in Radiology education and offer an easy to use platform for educating medical professionals based on Radiology cases.
International Nuclear Information System (INIS)
Bigot, J.M.; Moreau, J.F.; Nahum, H.; Bellet, M.
1990-01-01
The 17th International Congress of Radiology was conducted in two separate scientific sessions, one for radiodiagnosis and one for radiation oncology. Topics covered are: Radiobiology -radioprotection; imaging and data processing; contrast media; MRI; nuclear medicine; radiology and disasters; radiology of tropical diseases; cardiovascular radiology; interventional radiology; imaging of trauma; imaging of chest, gastro-intestinal tract, breast and genito-urinary tract; imaging in gynecology;imaging in oncology; bone and joint radiology; head and neck-radiology; neuro-radiology. (H.W.). refs.; fig.; tabs
Improving efficiency in the radiology department
Energy Technology Data Exchange (ETDEWEB)
Towbin, Alexander J.; Perry, Laurie A. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Larson, David B. [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)
2017-06-15
The modern radiology department is built around the flow of information. Ordering providers request imaging studies to be performed, technologists complete the work required to perform the imaging studies, and radiologists interpret and report on the imaging findings. As each of these steps is performed, data flow between multiple information systems, most notably the radiology information system (RIS), the picture archiving and communication system (PACS) and the voice dictation system. Even though data flow relatively seamlessly, the majority of our systems and processes are inefficient. The purpose of this article is to describe the radiology value stream and describe how radiology informaticists in one department have worked to improve the efficiency of the value stream at each step. Through these examples, we identify and describe several themes that we believe have been crucial to our success. (orig.)
Systematic Layout Planning of a Radiology Reporting Area to Optimize Radiologists' Performance.
Benitez, Guilherme Brittes; Fogliatto, Flavio Sanson; Cardoso, Ricardo Bertoglio; Torres, Felipe Soares; Faccin, Carlo Sasso; Dora, José Miguel
2018-04-01
Optimizing radiologists' performance is a major priority for managers of health services/systems, since the radiologists' reporting activity imposes a severe constraint on radiology productivity. Despite that, methods to optimize radiologists' reporting workplace layout are scarce in the literature. This study was performed in the Radiology Division (RD) of an 850-bed University-based general hospital. The analysis of the reporting workplace layout was carried out using the systematic layout planning (SLP) method, in association with cluster analysis as a complementary tool in early stages of SLP. Radiologists, architects, and hospital managers were the stakeholders consulted for the completion of different stages of the layout planning process. A step-by-step description of the proposed methodology to plan an RD reporting layout is presented. Clusters of radiologists were defined using types of exams reported and their frequency of occurrence as clustering variables. Sectors with high degree of interaction were placed in proximity in the new RD layout, with separation of noisy and quiet areas. Four reporting cells were positioned in the quiet area, grouping radiologists by subspecialty, as follows: cluster 1-abdomen; cluster 2-musculoskeletal; cluster 3-neurological, vascular and head & neck; cluster 4-thoracic and cardiac. The creation of reporting cells has the potential to limit unplanned interruptions and enhance the exchange of knowledge and information within cells, joining radiologists with the same expertise. That should lead to improvements in productivity, allowing managers to more easily monitor radiologists' performance.
Radiological performance assessment for the Z-Area Saltstone Disposal Facility
Energy Technology Data Exchange (ETDEWEB)
Cook, J.R.; Fowler, J.R. [Westinghouse Savannah River Co., Aiken, SC (United States)
1992-12-18
This radiological performance assessment (RPA) for the Savannah River Site (SRS) Saltstone Disposal Facility (SDF) was prepared in accordance with the requirements of Chapter III of the US Department of Energy Order 5820.2A. The Order specifies that an RPA should provide reasonable assurance that a low-level waste (LLW) disposal facility will comply with the performance objectives of the Order. The performance objectives require that: (1) exposures of the general public to radioactivity in the waste or released from the waste will not result in an effective dose equivalent of 25 mrem per year; (2) releases to the atmosphere will meet the requirements of 40 CFR 61; (3) inadvertent intruders will not be committed to an excess of an effective dose equivalent of 100 mrem per year from chronic exposure, or 500 mrem from a single acute exposure; and (4) groundwater resources will be protected in accordance with Federal, State and local requirements.
Radiological performance assessment for the Z-Area Saltstone Disposal Facility
International Nuclear Information System (INIS)
Cook, J.R.; Fowler, J.R.
1992-01-01
This radiological performance assessment (RPA) for the Savannah River Site (SRS) Saltstone Disposal Facility (SDF) was prepared in accordance with the requirements of Chapter III of the US Department of Energy Order 5820.2A. The Order specifies that an RPA should provide reasonable assurance that a low-level waste (LLW) disposal facility will comply with the performance objectives of the Order. The performance objectives require that: (1) exposures of the general public to radioactivity in the waste or released from the waste will not result in an effective dose equivalent of 25 mrem per year; (2) releases to the atmosphere will meet the requirements of 40 CFR 61; (3) inadvertent intruders will not be committed to an excess of an effective dose equivalent of 100 mrem per year from chronic exposure, or 500 mrem from a single acute exposure; and (4) groundwater resources will be protected in accordance with Federal, State and local requirements
General Employee Radiological Training: Study guide
International Nuclear Information System (INIS)
1992-10-01
Upon completion of this class, the participant will be able to discuss his/her responsibilities for maintaining exposures to radiation and radioactive material As Low As Reasonably Achievable. The participant will be able to select the correct response from a group of responses which verifies his/her ability to: Identify natural background and man-made sources of radiation; state the whole body radiation exposure limit for non-radiological workers; state the potential biological effects from chronic radiation exposure; identify the ALARA concept and practices; state methods used to control radiological material; and state employee responsibilities for the ALARA Program
International Nuclear Information System (INIS)
Benz-Bohm, G.
1997-01-01
Pediatric radiology is an important subsection of diagnostic radiology involving specific difficulties, but unfortunately is quite too often neglected as a subject of further education and training. The book therefore is not intended for specialists in the field, but for radiologists wishing to plunge deeper into the matter of pediatric radiology and to acquire a sound, basic knowledge and information about well-proven modalities, the resulting diagnostic images, and interpretation of results. The book is a compact guide and a helpful source of reference and information required for every-day work, or in special cases. With patients who are babies or children, the challenges are different. The book offers all the information needed, including important experience from pediatric hospital units that may be helpful in diagnostic evaluation, information about specific dissimilarities in anatomy and physiology which affect the imaging results, hints for radiology planning and performance, as well as information about the various techniques and their indication and achievements. The book presents a wide spectrum of informative and annotated images. (orig./CB) [de
C. Giuroiu; Maria Vataman; Liana Aminov; Mihaela Sălceanu; S. Andrian
2012-01-01
The present study aimed at assesssing – by clinical, histological and radiological investigations – the influence of some external factors on the pulp-dentin complex, and at providing a causal interpretation of the structural changes observed. Materials and methods. Clinical and radiological exams were performed on 65 old patients with ages between 60-75, and also on 40 young patients with ages between 20-35, presenting different dental-periodontal pathologies. The ...
Directory of Open Access Journals (Sweden)
Alexander R. Margulis
2011-07-01
Full Text Available It has been my good fortune to live and practice radiology during a long period of momentous change – to see the transformation of the discipline from a supportive service into a mainstream, essential branch of clinical medicine. I remember wearing red goggles to adapt my vision before performing fluoroscopy; observing the horrible, now thankfully obsolete, practice of ventriculography, which was considered advanced neuroradiology; and performing other, now rarely prescribed procedures, such as double-contrast barium enemas and intravenous pyelography. Witnessing the beginnings of interventional radiology, I suggested its name in an editorial. I also had the good fortune to see the introduction of computed tomography (CT and a technology first known as nuclear magnetic resonance imaging. Together with fellow members of a committee of the American College of Radiology and editors of prestigious radiological journals, I took part in changing the name of the latter modality to MRI, freeing it from threatening implications. Looking back on these experiences, one lesson stands out above all: Innovation and transformation never cease. Looking forward, it is clear that radiology, along with the rest of medicine, is now undergoing further momentous changes that will affect the future of all those already practicing as well as those yet to start their careers.
Review of Atomic Energy Laws Related to Radiological Accidents and Methods of Improvement
Energy Technology Data Exchange (ETDEWEB)
Chang, Gun Hyun; Kim, Sang Won; Yoo, Jeong; Ahn, Hyoung Jun; Park, Young Sik; Kim, Hong Suk; Kwon, Jeong Wan; Jang, Ki Won; Kim, Sok Chul [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)
2009-05-15
Atomic energy-related laws in Korea have a two pronged management system for radiological accidents. To be specific, the Atomic Energy Act is applicable to all radiological accidents, i.e. accidents pertaining to nuclear facilities and radioactive materials while the Act for Physical Protection and Radiological Emergency ('APPRE') applies to accidents related to nuclear materials and large-scale nuclear facilities. The Atomic Energy Act contains three provisions directly related with radiological accidents (Articles 89, 98 and 102). Article 89 provides for the obligations of nuclear licensees or consigned transporters to institute safety measures and file a report to the head of the Ministry of Education, Science and Technology ('MEST') in the event of any radiological accident during transport or packing of radioactive materials, etc. Article 98 stipulates obligations of nuclear licensees to implement safety procedures and submit a report to the Minister of Education, Science and Technology concerning radiation hazards arising in the event a radiological accident occurs in connection with nuclear projects, as well as the Minister's requests to implement necessary measures. Article 102 explicitly provides for obligations to file a report to the Minister in the event of theft, loss, fire or other accidents involving radioactive materials, etc. in the possession of nuclear licensees. The APPRE classifies radiological accidents according to location and scale of the accidents. Based on location, accidents are divided into accidents inside or outside nuclear facilities. Accidents inside nuclear facilities refer to accidents that occur at nuclear reactors, nuclear fuel cycling facilities, radioactive waste storage, treatment and disposal facilities, facilities using nuclear materials and facilities related to radioisotopes of not lower than 18.5PBq (Subparagraph 2, Article 2 of the APPRE) while accidents outside nuclear facilities mean accidents
Review of Atomic Energy Laws Related to Radiological Accidents and Methods of Improvement
International Nuclear Information System (INIS)
Chang, Gun Hyun; Kim, Sang Won; Yoo, Jeong; Ahn, Hyoung Jun; Park, Young Sik; Kim, Hong Suk; Kwon, Jeong Wan; Jang, Ki Won; Kim, Sok Chul
2009-01-01
Atomic energy-related laws in Korea have a two pronged management system for radiological accidents. To be specific, the Atomic Energy Act is applicable to all radiological accidents, i.e. accidents pertaining to nuclear facilities and radioactive materials while the Act for Physical Protection and Radiological Emergency ('APPRE') applies to accidents related to nuclear materials and large-scale nuclear facilities. The Atomic Energy Act contains three provisions directly related with radiological accidents (Articles 89, 98 and 102). Article 89 provides for the obligations of nuclear licensees or consigned transporters to institute safety measures and file a report to the head of the Ministry of Education, Science and Technology ('MEST') in the event of any radiological accident during transport or packing of radioactive materials, etc. Article 98 stipulates obligations of nuclear licensees to implement safety procedures and submit a report to the Minister of Education, Science and Technology concerning radiation hazards arising in the event a radiological accident occurs in connection with nuclear projects, as well as the Minister's requests to implement necessary measures. Article 102 explicitly provides for obligations to file a report to the Minister in the event of theft, loss, fire or other accidents involving radioactive materials, etc. in the possession of nuclear licensees. The APPRE classifies radiological accidents according to location and scale of the accidents. Based on location, accidents are divided into accidents inside or outside nuclear facilities. Accidents inside nuclear facilities refer to accidents that occur at nuclear reactors, nuclear fuel cycling facilities, radioactive waste storage, treatment and disposal facilities, facilities using nuclear materials and facilities related to radioisotopes of not lower than 18.5PBq (Subparagraph 2, Article 2 of the APPRE) while accidents outside nuclear facilities mean accidents that take place on
Development of mobile radiological assessment laboratory
International Nuclear Information System (INIS)
Pujari, R.N.; Saindane, Shashank S.; Jain, Amit; Parmar, Jayesh; Narsaiah, M.V.R.; Pote, M.B.; Murali, S.; Chaudhury, Probal
2018-01-01
During any emergency situations real-time radiation measurements and the fast analysis of the measured radiological data are of crucial importance. The newly developed mobile vehicle based laboratory known as 'Radiological Assessment Laboratory' (RAL) can be used for real time measurements in different radiation emergency scenarios, such as the release of radioactive materials from a radiological/nuclear incident, during search of an orphan source or during radioisotope transportation. RAL is equipped with several high sensitive detectors/systems such as NaI(Tl) gamma spectrometers, large size plastic scintillators and air-sampler, along with GPS and data transfer capability through GSM modem
Radiological protection for the dental practice
International Nuclear Information System (INIS)
Mora Rodriguez, Patricia; Loria Meneses, Luis Guillermo
2007-01-01
This work offers a didactical material, of easy reading and without mathematical complexity, about the fundamentals of the radiological protection in the dental area. It is dedicated to the personnel of the Ministerio de Salud, responsible to realize radiological inspection in dentistry clinics of the country. It is recommended to consult other bibliographical references if it is wished to extend about a particular subject [es
International Nuclear Information System (INIS)
Wallis, A.; Edey, A.; Prothero, D.; McCoubrie, P.
2013-01-01
Aim: To review the development of a workplace-based assessment tool to assess the quality of written radiology reports and assess its reliability, feasibility, and validity. Materials and methods: A comprehensive literature review and rigorous Delphi study enabled the development of the Bristol Radiology Report Assessment Tool (BRRAT), which consists of 19 questions and a global assessment score. Three assessors applied the assessment tool to 240 radiology reports provided by 24 radiology trainees. Results: The reliability coefficient for the 19 questions was 0.79 and the equivalent coefficient for the global assessment scores was 0.67. Generalizability coefficients demonstrate that higher numbers of assessors and assessments are needed to reach acceptable levels of reliability for summative assessments due to assessor subjectivity. Conclusion: The study methodology gives good validity and strong foundation in best-practice. The assessment tool developed for radiology reporting is reliable and most suited to formative assessments
Radiological Worker II Training, Course 20301 (Live), Course 12909 (Test)
Energy Technology Data Exchange (ETDEWEB)
Harris, Jimmy D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
2017-01-13
Radiological worker training is the basic building block for any additional radiological training you may receive. Upon completing radiological worker training, you will have the basic knowledge needed to work safely, using proper radiological practices, in areas where radiological hazards exist. You will also have a better understanding of the hazards and responsibilities associated with radiological work to help prevent the carelessness that can occur when working continually with or around radioactive material. This course does not qualify you for any specific radiological work. You may be required to take additional training at individual facilities to address facility- and job-specific hazards and procedures.
International Nuclear Information System (INIS)
Reichelt, Andreas; Niedermayer, Matthias; Sitte, Beate; Hamel, Peter Michael
2007-01-01
Natural radionuclides are part of the human environment and of the raw materials used. Technical processes may cause their accumulation in residues, and the result will be so-called NORM materials (Naturally occurring radioactive material). The amended Radiation Protection Ordinance (StrlSchV 2001) specifies how the public should be protected, but there are also residues dating back before the issuing of the StrlSchV 2001, the so-called NORM residues. The project intended to assess the risks resulting from these residues. It comprises four parts. Part 1 was for clarification of the radiological relevance of NORM residues and for the development of concepts to detect them. The criterion for their radiological relevance was their activity per mass unit and the material volume accumulated through the centuries. The former was calculated from a wide bibliographic search in the relevant literature on radiation protection, while the mass volume was obtained by a detailed historical search of the consumption of materials that may leave NORM residues. These are, in particular, residues from coal and ore mining and processing. To identify concrete sites, relevant data sources were identified, and a concept for identification of concrete NORM residues was developed on this basis. (orig.) [de
International Nuclear Information System (INIS)
Hochel, R.C.
1999-01-01
The cost effective radiological classification and disposal of solid materials with potential volume contamination, in accordance with applicable U.S. Department of Energy (DOE) Orders, suffers from an inability to unambiguously distinguish among transuranic waste, low-level waste, and unconditional-release materials. Depending on the classification, disposal costs can vary by a hundred-fold. But in many cases, the issues can be easily resolved by a combination of process information, some simple measurements, and calculational predictions from a computer model for radiation shielding.The proper classification and disposal of many solid wastes requires a measurement regime that is able to show compliance with a variety of institutional and regulatory contamination limits. Although this is not possible for all solid wastes, there are many that do lend themselves to such measures. Several examples are discussed which demonstrate the possibilities, including one which was successfully applied to bulk contamination.The only barriers to such broader uses are the slow-to-change institutional perceptions and procedures. For many issues and materials, the measurement tools are available; they need only be applied
Energy Technology Data Exchange (ETDEWEB)
Hochel, R.C.
1999-06-14
The cost effective radiological classification and disposal of solid materials with potential volume contamination, in accordance with applicable U.S. Department of Energy (DOE) Orders, suffers from an inability to unambiguously distinguish among transuranic waste, low-level waste, and unconditional-release materials. Depending on the classification, disposal costs can vary by a hundred-fold. But in many cases, the issues can be easily resolved by a combination of process information, some simple measurements, and calculational predictions from a computer model for radiation shielding.The proper classification and disposal of many solid wastes requires a measurement regime that is able to show compliance with a variety of institutional and regulatory contamination limits. Although this is not possible for all solid wastes, there are many that do lend themselves to such measures. Several examples are discussed which demonstrate the possibilities, including one which was successfully applied to bulk contamination.The only barriers to such broader uses are the slow-to-change institutional perceptions and procedures. For many issues and materials, the measurement tools are available; they need only be applied.
Quality assurance in diagnostic radiology
International Nuclear Information System (INIS)
1982-01-01
The present guide endeavours to provide an outline of the type of quality assurance programme to be recommended for (1) routine implementation by those performing radiodiagnostic procedures (medical radiology technicians, medical physicists, and radiologists), (2) for application by the responsible national authorities, and (3) for use by international bodies such as the International Society of Radiology (ISR), the International Commission on Radiological Protection (ICRP), and the International Commission on Radiation Units and Measurements (ICRU)
The economics of interventional radiology
International Nuclear Information System (INIS)
Price, G.W.
1988-01-01
At a time when policy makers and regulators are scheming to reduce the costs and utilization of medical services, interventional radiology is poised for growth. Part of this potential for growth is based on wider acceptance of the procedures performed by interventional radiologists. A second factor in the growth potential is the relative value in cost of these procedures compared with alternative therapies. The author presents a discussion of the differences in the relative value of these procedures when performed by physicians of different specialties. This paper reviews the status of the economic climate in the health care delivery system and the role and potential growth of interventional radiology. This includes a review of current data on the utilization of interventional radiology procedures in the Medicare program. This overview includes a discussion of the initiatives of the federal government which directly impact interventional radiology
International Nuclear Information System (INIS)
1995-10-01
There we show works of the Third Regional Meeting on Radiological and Nuclear Safety held on 23-27 October, 1995 in Cusco-Peru. Latin americans specialists talk about nuclear safety and radiological protection, radiation natural exposure, biological effect of radiation, radiotherapy and medical radiological safety, radiological safety in industry and research. Also we deal with subjects related to radiological safety of nuclear and radioactive facilities, radioactive waste management, radioactive material transport, environmental radiological monitoring program, radiological emergency and accidents, instruments and dosimetry, basic safety standards of protection against radiation. More than 225 works were presented on the meeting
Design And Measurement Of Radiation Exposure Rates At An X-Ray Diagnostic Radiological Unit
International Nuclear Information System (INIS)
Tito-Sutjipto
2003-01-01
Every radiation employees suffers radiation exposure risk while doing his job. It is important therefore to investigate the occupational health and safety of radiation employees on its relationship with the design and measurement of radiation exposure rates at an X-ray diagnostic radiological unit in this work, a case study was held on the radiological unit at BP-4 Yogyakarta for patient diagnostics, This research armed to investigate the relationship between the design of radiological unit for X-ray diagnostics and the location of the X-ray machine, based on the distance variable and radiation exposure rate during patient diagnostics. This was performed using radiological unit design data for X-ray diagnostics and the measurement of radiation exposure rates throughout patient diagnostics. The design data can then be used for determining the requirement of primary and secondary shielding materials for radiological unit as well as a calculation basis of radiation exposure rates during patient diagnostics. From the result of the research, it can be concluded that from the occupational health and safety point of view, radiation exposure around the X-ray machines are fairly good, both for the shielding materials in each X-ray room and the radiation exposures received by the workers, because they are far beyond the maximum permittable average limit (16.67 m R/days). (author)
International Nuclear Information System (INIS)
Wallner, Paul E.; Ang, K. Kian; Zietman, Anthony L.; Harris, Jay R.; Ibbott, Geoffrey S.; Mahoney, Mary C.; Mezwa, Duane G.; Wilson, Lynn D.; Becker, Gary J.
2013-01-01
Introduction: In 1999, the American Board of Radiology (ABR) implemented an innovative training program track in diagnostic radiology (DR) and radiation oncology (RO) designed to stimulate development of a cadre of future academic researchers and educators in the 2 disciplines. The program was designated the Holman Research Pathway (HRP). An in-depth retrospective review of initial certification examination performance, post-training career choices, and academic productivity has not been written. This report represents a 10-year retrospective review of post-training performance of a cohort of trainees who have had sufficient time to complete their training and initial certification process and to enter practice. Methods and Materials: All pertinent proceedings of the ABR and Accreditation Council for Graduate Medical Education (ACGME) Residency Review Committees for DR and RO between 1997 and May 2011 were reviewed. Thirty-four HRP candidates who fulfilled the established evaluation criteria were identified, and their ABR data files were analyzed regarding performance on the qualifying and certifying examinations. All candidates were contacted directly to obtain a current curriculum vitae. Results: Twenty candidates in RO and 14 candidates in DR were identifiable for review. All candidates attained initial certification. At the time of analysis, 23 of 33 (66.6%) candidates were employed in full-time academic practice (1 DR candidate remained in a fellowship and was not evaluated regarding employment status). Fifteen of 20 (75%) RO candidates were in faculty positions compared with 7 of 13 (53.8%) DR trainees. Additional academic productivity metrics are reported. Conclusions: A high percentage of HRP trainees remained in academic practice and demonstrated significant academic productivity as measured by manuscript authorship and research support. Additional time and observation will be needed to determine whether these findings will be sustained by past, current
Hemming, C R; Charles, D; Ostmeyer, R M
1983-01-01
This report describes a comparison of the MARC (Methodology for Assessing Radiological Consequences) and CRAC2 (Calculation of Reactor Accident Consequences, version 2) computer programs for assessing the radiological consequences of accidental releases of radioactive material. A qualitative comparison has been made of the features of the constituent sub-models of the two codes, and potentially the most important differences identified. The influence of these differences has been investigated quantitatively by comparison of the predictions of the two codes in a wide variety of circumstances. Both intermediate quantities and endpoints used as a measure of risk have been compared in order to separate the variables more clearly. The results indicate that, in general, the predictions of MARC and CRAC2 are in good agreement.
Radiation Detection System for Prevention of Radiological and Nuclear Terrorism
International Nuclear Information System (INIS)
Kwak, Sung-Woo; Yoo, Ho-Sik; Jang, Sung-Sun; Kim, Jae-Kwang; Kim, Jung-Soo
2007-01-01
After the September 11 terrorist attack, the threat of a potential for a radiological or nuclear terrorist attack became more apparent. The threats relating to radiological or nuclear materials include a Radiological Dispersion Device (RDD), an Improved Nuclear Device (IND) or a State Nuclear Device (such as a Soviet manufactured suitcase nuclear weapon). For more effective countermeasures against the disaster, multilayer protection concept - prevention of smuggling of radioactive or nuclear material into our country through seaports or airports, detection and prevention of the threat materials in transit on a road, and prevention of their entry into a target building - is recommended. Due to different surrounding circumstances of where detection system is deployed, different types of radiation detection systems are required. There have been no studies on characteristics of detection equipment required under Korean specific conditions. This paper provides information on technical requirements of radiation detection system to achieve multi-layer countermeasures for the purpose of protecting the public and environment against radiological and nuclear terrorism
Learning from diagnostic errors: A good way to improve education in radiology
Energy Technology Data Exchange (ETDEWEB)
Pinto, Antonio, E-mail: antopin1968@libero.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Acampora, Ciro, E-mail: itrasente@libero.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Pinto, Fabio, E-mail: fpinto1966@libero.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Kourdioukova, Elena, E-mail: Elena.Kourdioukova@UGent.be [Department of Radiology, Ghent University Hospital (UZG), MR/-1K12, De Pintelaan 185, B-9000 Ghent (Belgium); Romano, Luigia, E-mail: luigia.romano@fastwebnet.it [Department of Diagnostic Imaging, A. Cardarelli Hospital, I-80131 Naples (Italy); Verstraete, Koenraad, E-mail: Koenraad.Verstraete@UGent.be [Department of Radiology, Ghent University Hospital (UZG), MR/-1K12, De Pintelaan 185, B-9000 Ghent (Belgium)
2011-06-15
Purpose: To evaluate the causes and the main categories of diagnostic errors in radiology as a method for improving education in radiology. Material and methods: A Medline search was performed using PubMed (National Library of Medicine, Bethesda, MD) for original research publications discussing errors in diagnosis with specific reference to radiology. The search strategy employed different combinations of the following terms: (1) diagnostic radiology, (2) radiological error and (3) medical negligence. This review was limited to human studies and to English-language literature. Two authors reviewed all the titles and subsequently the abstracts of 491 articles that appeared pertinent. Additional articles were identified by reviewing the reference lists of relevant papers. Finally, the full text of 75 selected articles was reviewed. Results: Several studies show that the etiology of radiological error is multi-factorial. The main category of claims against radiologists includes the misdiagnoses. Radiologic 'misses' typically are one of two types: either missed fractures or missed diagnosis of cancer. The most commonly missed fractures include those in the femur, the navicular bone, and the cervical spine. The second type of 'miss' is failure to diagnose cancer. Lack of appreciation of lung nodules on chest radiographs and breast lesions on mammograms are the predominant problems. Conclusion: Diagnostic errors should be considered not as signs of failure, but as learning opportunities.
Learning from diagnostic errors: A good way to improve education in radiology
International Nuclear Information System (INIS)
Pinto, Antonio; Acampora, Ciro; Pinto, Fabio; Kourdioukova, Elena; Romano, Luigia; Verstraete, Koenraad
2011-01-01
Purpose: To evaluate the causes and the main categories of diagnostic errors in radiology as a method for improving education in radiology. Material and methods: A Medline search was performed using PubMed (National Library of Medicine, Bethesda, MD) for original research publications discussing errors in diagnosis with specific reference to radiology. The search strategy employed different combinations of the following terms: (1) diagnostic radiology, (2) radiological error and (3) medical negligence. This review was limited to human studies and to English-language literature. Two authors reviewed all the titles and subsequently the abstracts of 491 articles that appeared pertinent. Additional articles were identified by reviewing the reference lists of relevant papers. Finally, the full text of 75 selected articles was reviewed. Results: Several studies show that the etiology of radiological error is multi-factorial. The main category of claims against radiologists includes the misdiagnoses. Radiologic 'misses' typically are one of two types: either missed fractures or missed diagnosis of cancer. The most commonly missed fractures include those in the femur, the navicular bone, and the cervical spine. The second type of 'miss' is failure to diagnose cancer. Lack of appreciation of lung nodules on chest radiographs and breast lesions on mammograms are the predominant problems. Conclusion: Diagnostic errors should be considered not as signs of failure, but as learning opportunities.
DOE Radiological Control Manual Core Training Program
International Nuclear Information System (INIS)
Scott, H.L.; Maisler, J.
1993-01-01
Over the past year, the Department of Energy (DOE) Office of Health (EH-40) has taken a leading role in the development of new standardized radiological control training programs for use throughout the DOE complex. The Department promulgated its Radiological Control (RadCon) Manual in June 1992. To ensure consistent application of the criteria presented in the RadCon Manual, standardized radiological control core training courses and training materials have been developed for implementation at all DOE facilities. In producing local training programs, standardized core courses are to be supplemented with site-specific lesson plans, viewgraphs, student handbooks, qualification standards, question banks, and wallet-sized training certificates. Training programs for General Employee Radiological Training, Radiological Worker I and II Training, and Radiological Control Technician Training have been disseminated. Also, training committees under the direction of the Office of Health (EH-40) have been established for the development of additional core training courses, development of examination banks, and the update of the existing core training courses. This paper discusses the current activities and future direction of the DOE radiological control core training program
Design aspects of radiological safety in nuclear facilities
International Nuclear Information System (INIS)
Patkulkar, D.S.; Purohit, R.G.; Tripathi, R.M.
2014-01-01
In order to keep operational performance of a nuclear facility high and to keep occupational and public exposure ALARA, radiological safety provisions must be reviewed at the time of facility design. Deficiency in design culminates in deteriorated system performance and non adherence to safety standards and could sometimes result in radiological incident. Important radiological aspects relevant to safety were compiled based on operating experiences, design deficiencies brought out from past nuclear incidents, experience gained during maintenance, participation in design review of upcoming nuclear facilities and radiological emergency preparedness
Radiological risk of building materials using homemade airtight radon chamber
International Nuclear Information System (INIS)
Norafatin Khalid; Amran Abdul Majid; Redzuwan Yahaya; Muhammad Samudi Yasir
2013-01-01
Full-text: Soil based building materials known to contain various amounts of natural radionuclide mainly 238 U and 232 Th series and 40 K. In general most individuals spend 80 % of their time indoors and the natural radioactivity in building materials is a main source of indoor radiation exposure. The internal exposure due to building materials in dwellings and workplaces is mainly caused by the activity concentrations of short lived 222 Radon and its progenies which arise from the decay of 226 Ra. In this study, the indoor radon concentration emanating from cement brick, red-clay brick, gravel aggregate and Portland cement samples were measured in a homemade airtight radon chamber using continuous radon monitor 1029 model of Sun Nuclear. Radon monitor were left in the chamber for 96 hours with an hour counting time interval. From the result, the indoor radon concentrations for cement brick, red-clay brick, gravel aggregate and Portland cement samples determined were 396 Bq m -3 , 192 Bq m -3 , 176 Bq m -3 and 28 Bq m -3 , respectively. The result indicates that the radon concentration in the studied building materials have more than 100 Bq m -3 for example higher than the WHO action level except for Portland cement sample. The calculated annual effective dose for cement brick, red-clay brick, gravel aggregate and Portland cement samples were determined to be 10 mSv y -1 , 4.85 mSv y -1 , 4.44 mSv y -1 and 0.72 mSv y -1 , respectively. This study showed that all the calculated effective doses generated from indoor radon to dwellers or workers were in the range of limit recommended ICRP action levels for example 3 - 10 mSv y -1 . As consequences, the radiological risk for the dwellers in terms of fatal lifetime cancer risk per million for cement brick, red-clay brick, gravel aggregate and Portland cement were calculated to be 550, 267, 244 and 40 persons respectively. (author)
Radiological risk of building materials using homemade airtight radon chamber
International Nuclear Information System (INIS)
Khalid, Norafatin; Majid, Amran Ab.; Yahaya, Redzuwan; Yasir, Muhammad Samudi
2014-01-01
Soil based building materials known to contain various amounts of natural radionuclide mainly 238 U and 232 Th series and 40 K. In general most individuals spend 80% of their time indoors and the natural radioactivity in building materials is a main source of indoor radiation exposure. The internal exposure due to building materials in dwellings and workplaces is mainly caused by the activity concentrations of short lived 222 Radon and its progenies which arise from the decay of 226 Ra. In this study, the indoor radon concentration emanating from cement brick, red-clay brick, gravel aggregate and Portland cement samples were measured in a homemade airtight radon chamber using continuous radon monitor 1029 model of Sun Nuclear. Radon monitor were left in the chamber for 96 hours with an hour counting time interval. From the result, the indoor radon concentrations for cement brick, red-clay brick, gravel aggregate and Portland cement samples determined were 396 Bq m −3 , 192 Bq m −3 , 176 Bq m −3 and 28 Bq m −3 , respectively. The result indicates that the radon concentration in the studied building materials have more than 100 Bq m −3 i.e. higher than the WHO action level except for Portland cement sample. The calculated annual effective dose for cement brick, red-clay brick, gravel aggregate and Portland cement samples were determined to be 10 mSv y −1 , 4.85 mSv y −1 , 4.44 mSv y −1 and 0.72 mSv y −1 , respectively. This study showed that all the calculated effective doses generated from indoor radon to dwellers or workers were in the range of limit recommended ICRP action levels i.e. 3 - 10 mSv y −1 . As consequences, the radiological risk for the dwellers in terms of fatal lifetime cancer risk per million for cement brick, red-clay brick, gravel aggregate and Portland cement were calculated to be 550, 267, 244 and 40 persons respectively
Image Quality in Vascular Radiology
International Nuclear Information System (INIS)
Vanhavere, F.; Struelens, L.
2005-01-01
In vascular radiology, the radiologists use the radiological image to diagnose or treat a specific vascular structure. From literature, we know that related doses are high and that large dose variability exists between different hospitals. The application of the optimization principle is therefore necessary and is obliged by the new legislation. So far, very little fieldwork has been performed and no practical instructions are available to do the necessary work. It's indisputable that obtaining quantitative data is of great interest for optimization purposes. In order to gain insight into these doses and the possible measures for dose reduction, we performed a comparative study in 7 hospitals. Patient doses will be measured and calculated for specific procedures in vascular radiology and evaluated against their most influencing parameters. In view of optimization purposes, a protocol for dose audit will be set-up. From the results and conclusions in this study, experimentally based guidelines will be proposed, in order to improve clinical practice in vascular radiology
A New Role for Local Police in Radiological Security
National Research Council Canada - National Science Library
Lee, Thomas
2007-01-01
.... Local police agencies have previously not had a formal role in radiological security. This thesis explores policy initiatives, based on community policing principles conducted at the local police level, which will enhance security at locations where radiological materials are kept.
Glover, McKinley; Choy, Garry; Boland, Giles W; Saini, Sanjay; Prabhakar, Anand M
2015-05-01
This study assesses the prevalence of use of the most commonly used social media sites among private radiology groups (PRGs) and academic radiology departments (ARDs). The 50 largest PRGs and the 50 ARDs with the highest level of funding from the National Institutes of Health were assessed for presence of a radiology-specific social media account on Facebook, Twitter, Instagram, Pinterest, YouTube, and LinkedIn. Measures of organizational activity and end-user activity were collected, including the number of posts and followers, as appropriate; between-group comparisons were performed. PRGs adopted Facebook 12 months earlier (P = .02) and Twitter 18 months earlier (P = .02) than did ARDs. A total of 76% of PRGs maintained ≥1 account on the social media sites included in the study, compared with 28% of ARDs (P Instagram, 2%. The prevalence of radiology-specific social media accounts for ARDs was: Facebook, 18%; LinkedIn, 0%; Twitter, 24%; YouTube, 6%; Pinterest, 0%; and Instagram, 0%. There was no significant difference between ARDs and PRGs in measures of end-user or organizational activity on Facebook or Twitter. Use of social media in health care is emerging as mainstream, with PRGs being early adopters of Facebook and Twitter in comparison with ARDs. Competitive environments and institutional policies may be strong factors that influence how social media is used by radiologists at the group and department levels. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Energy Technology Data Exchange (ETDEWEB)
Nass, Jens
2010-07-01
The report on the risk of attacks with chemical, biological, radiological and nuclear weapons or materials covers the following topics: the variety of terrorism: ethnic-nationalistic, politically motivated, social revolutionary, political extremism, religious fanaticism, governmental terrorism; CBRN (chemical, biological, radiological, nuclear) weapons and materials: their availability and effectiveness in case of use; potential actor groups; prevention and counter measures, emergency and mitigating measures.
International Nuclear Information System (INIS)
Meena, T.R.; Anoj Kumar; Patra, R.P.; Vikas; Patil, S.S.; Chatterjee, M.K.; Sharma, Ranjit; Murali, S.
2014-01-01
National level response mechanism is developed at emergency response centres of DAE (DAE-ERCs) at 22 different locations spread all over the country and National Disaster Response Forces with National Disaster Management Authority (NDMA). ERCs are equipped with radiation monitors, radionuclide identifinders, Personnel Radiation Dosimeters (PRD) with monitoring capabilities of the order of tens of nGy/h (μR/hr) above the radiation background at any suspected locations. Even if small amounts of radioactive material is smuggled and brought in some other form into public domain, ERCs are capable to detect, identify and segregate the radioactive material from any inactive scrap. DAE-ERCs have demonstrated their capability in source search, detection, identification and recovery during the radiological emergency at Mayapuri, New Delhi
Energy Technology Data Exchange (ETDEWEB)
Meena, T. R.; Kumar, Anoj; Patra, R. P.; Vikas,; Patil, S. S.; Chatterjee, M. K.; Sharma, Ranjit; Murali, S., E-mail: tejram@barc.gov.in [Radiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai (India)
2014-07-01
National level response mechanism is developed at emergency response centres of DAE (DAE-ERCs) at 22 different locations spread all over the country and National Disaster Response Forces with National Disaster Management Authority (NDMA). ERCs are equipped with radiation monitors, radionuclide identifinders, Personnel Radiation Dosimeters (PRD) with monitoring capabilities of the order of tens of nGy/h (μR/hr) above the radiation background at any suspected locations. Even if small amounts of radioactive material is smuggled and brought in some other form into public domain, ERCs are capable to detect, identify and segregate the radioactive material from any inactive scrap. DAE-ERCs have demonstrated their capability in source search, detection, identification and recovery during the radiological emergency at Mayapuri, New Delhi.
History of metaphoric signs in radiology
Energy Technology Data Exchange (ETDEWEB)
Baker, Stephen R., E-mail: bakersr@umdnj.edu; Noorelahi, Yasser M., E-mail: dr.ynoorelahi@gmail.com; Ghosh, Shanchita, E-mail: Ghoshs1@umdnj.edu; Yang, Lily C., E-mail: yangclily@gmail.com; Kasper, David J., E-mail: dkasp86@gmail.com
2013-09-15
Purpose: To survey the nearly 100 year history of metaphoric sign naming in radiology describing the pace of their overall accumulation in the radiology canon, their specific rates of growth by modality and subspecialty and the characteristics of the referents to which the signs are attached. Materials and methods: A comprehensive list of metaphoric signs was compiled from a search of articles in several major English language radiology journals, from a roster compiled in a monograph on the subject published in 1984 and from a search of several databases to find signs published in the first half of the 20th century. Results: The growth of radiological metaphorical signs naming was slow for several decades after the first one was published in 1918. It then increased rapidly until the 1980s encompassing all modalities and subspecialties. Recently the practice has shown a marked and steady decline. Conclusion: Metaphoric sign naming was a frequently reported contribution to the radiological literature in the second half of the 20th century corresponding with Radiology's growth as a descriptive discipline. Its decline since then may be a consequence of Radiology's evolution into a more analytic, data-driven field of inquiry.
History of metaphoric signs in radiology
International Nuclear Information System (INIS)
Baker, Stephen R.; Noorelahi, Yasser M.; Ghosh, Shanchita; Yang, Lily C.; Kasper, David J.
2013-01-01
Purpose: To survey the nearly 100 year history of metaphoric sign naming in radiology describing the pace of their overall accumulation in the radiology canon, their specific rates of growth by modality and subspecialty and the characteristics of the referents to which the signs are attached. Materials and methods: A comprehensive list of metaphoric signs was compiled from a search of articles in several major English language radiology journals, from a roster compiled in a monograph on the subject published in 1984 and from a search of several databases to find signs published in the first half of the 20th century. Results: The growth of radiological metaphorical signs naming was slow for several decades after the first one was published in 1918. It then increased rapidly until the 1980s encompassing all modalities and subspecialties. Recently the practice has shown a marked and steady decline. Conclusion: Metaphoric sign naming was a frequently reported contribution to the radiological literature in the second half of the 20th century corresponding with Radiology's growth as a descriptive discipline. Its decline since then may be a consequence of Radiology's evolution into a more analytic, data-driven field of inquiry
Radiological findings and interventions for iatrogenic vascular injuries
International Nuclear Information System (INIS)
Lee, Kyoung Ho; Chung, Jin Wook; Kim, Tae Kyoung; Han, Sang Wook; Lee, Jong Seog; Park, Jae Hyung; Kim, Jong Hyo; Han, Man Chung
1998-01-01
The purpose of this study is to evaluate the radiological findings and effectiveness of radiological interventions in patients with iatrogenic vascular injuries. We analyzed 50 patients with iatrogenic vascular injuries treated with radiological intervention. The causes of injuries were surgery (n=20), cardiovascular intervention (n=15), non-cardiovascular radiological intervention (n=14), and endoscopic intervention (n=1). The injury had resulted in hemorrhage in 35 cases. The iliac and/or femoral, hepatic, and renal vessels were commonly injured. Angiography, ultrasonography with Doppler examination, CT, and CT angiography were performed to diagnose vascular injuries and guide the radiological intervention. The mean follow-up period was 23 months and in 16 cases was more than one year. the major radiological findings were extravasation, pseudoaneurysm, arteriovenous shunt, or vascular obstruction. To control these lesions, radiological interventions such as embolization (n=36), local urokinase administration, stent insertion, foreign body removal, ultrasonography-guided compression, or stent-graft insertion were performed. The clinical problems were immediately controlled by the single trials of radiological interventions and did not recur in 40 cases (80%). Radiological examinations and interventions are useful in cases with iatrogenic vascular injuries. (author). 14 refs., 4 figs
Radiological Characterization and Final Facility Status Report Tritium Research Laboratory
International Nuclear Information System (INIS)
Garcia, T.B.; Gorman, T.P.
1996-08-01
This document contains the specific radiological characterization information on Building 968, the Tritium Research Laboratory (TRL) Complex and Facility. We performed the characterization as outlined in its Radiological Characterization Plan. The Radiological Characterization and Final Facility Status Report (RC ampersand FFSR) provides historic background information on each laboratory within the TRL complex as related to its original and present radiological condition. Along with the work outlined in the Radiological Characterization Plan (RCP), we performed a Radiological Soils Characterization, Radiological and Chemical Characterization of the Waste Water Hold-up System including all drains, and a Radiological Characterization of the Building 968 roof ventilation system. These characterizations will provide the basis for the Sandia National Laboratory, California (SNL/CA) Site Termination Survey .Plan, when appropriate
Radiological findings in NAO syndrome
Energy Technology Data Exchange (ETDEWEB)
Al-Otaibi, Leftan; Hugosson, Claes O. [Department of Radiology, King Faisal Specialist Hospital and Research Center, Riyadh (Saudi Arabia); Al-Mayouf, Sulalman M.; Majeed, Mahmoud; Al-Eid, Wea' am; Bahabri, Sultan [Department of Paediatrics, King Faisal Specialist Hospital and Research Center, Riyadh (Saudi Arabia)
2002-07-01
Background: Diseases exhibiting osteolysis in children are rare hereditary conditions. Several types have been recognised with different clinical manifestations. One type includes subcutaneous nodules, arthropathy and osteolysis and has been termed NAO syndrome. Previous radiological reports have described the affected bones, usually the carpal and tarsal regions, but a detailed analysis of the radiological findings of both the axial as well as the appendicular skeleton has not been reported. Objectives: To describe the radiological findings in a large group of children with an autosomal recessive disease characterized by nodules, familial arthropathy and osteolysis. Materials and methods: The study comprises 14 patients from 9 families and all patients had the triad of nodulosis, arthropathy and osteolysis (NAO). Results: The most common radiological manifestations were osteopenia, undertubulation of long bones, arthritic changes, sclerotic sutures of the calvaria, osteolysis and muscle contractures. Other common findings were squared vertebrae, broad medial clavicles and brachycephaly. Progress of disease was documented in more than half of the patients. Conclusions: Our study is the first report of the detailed radiological findings of NAO syndrome. In NAO syndrome, both the axial and appendicular skeleton are involved (orig.)
Radiological findings in NAO syndrome
International Nuclear Information System (INIS)
Al-Otaibi, Leftan; Hugosson, Claes O.; Al-Mayouf, Sulalman M.; Majeed, Mahmoud; Al-Eid, Wea'am; Bahabri, Sultan
2002-01-01
Background: Diseases exhibiting osteolysis in children are rare hereditary conditions. Several types have been recognised with different clinical manifestations. One type includes subcutaneous nodules, arthropathy and osteolysis and has been termed NAO syndrome. Previous radiological reports have described the affected bones, usually the carpal and tarsal regions, but a detailed analysis of the radiological findings of both the axial as well as the appendicular skeleton has not been reported. Objectives: To describe the radiological findings in a large group of children with an autosomal recessive disease characterized by nodules, familial arthropathy and osteolysis. Materials and methods: The study comprises 14 patients from 9 families and all patients had the triad of nodulosis, arthropathy and osteolysis (NAO). Results: The most common radiological manifestations were osteopenia, undertubulation of long bones, arthritic changes, sclerotic sutures of the calvaria, osteolysis and muscle contractures. Other common findings were squared vertebrae, broad medial clavicles and brachycephaly. Progress of disease was documented in more than half of the patients. Conclusions: Our study is the first report of the detailed radiological findings of NAO syndrome. In NAO syndrome, both the axial and appendicular skeleton are involved (orig.)
van der Gijp, A; Ravesloot, C J; Jarodzka, H; van der Schaaf, M F; van der Schaaf, I C; van Schaik, J P J; Ten Cate, Th J
2017-08-01
Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review of eye-tracking literature in the radiology domain aims to identify visual search patterns associated with high perceptual performance. Databases PubMed, EMBASE, ERIC, PsycINFO, Scopus and Web of Science were searched using 'visual perception' OR 'eye tracking' AND 'radiology' and synonyms. Two authors independently screened search results and included eye tracking studies concerning visual skills in radiology published between January 1, 1994 and July 31, 2015. Two authors independently assessed study quality with the Medical Education Research Study Quality Instrument, and extracted study data with respect to design, participant and task characteristics, and variables. A thematic analysis was conducted to extract and arrange study results, and a textual narrative synthesis was applied for data integration and interpretation. The search resulted in 22 relevant full-text articles. Thematic analysis resulted in six themes that informed the relation between visual search and level of expertise: (1) time on task, (2) eye movement characteristics of experts, (3) differences in visual attention, (4) visual search patterns, (5) search patterns in cross sectional stack imaging, and (6) teaching visual search strategies. Expert search was found to be characterized by a global-focal search pattern, which represents an initial global impression, followed by a detailed, focal search-to-find mode. Specific task-related search patterns, like drilling through CT scans and systematic search in chest X-rays, were found to be related to high expert levels. One study investigated teaching of visual search strategies, and did not find a significant effect on perceptual performance. Eye
International Nuclear Information System (INIS)
Davis, C.K.; Forbes, W.F.; Hayward, L.M.
1986-09-01
Occupational limits for exposure to ionizing radiation, in force in Canada, are based on recommendations of international bodies, particularly the International Commission on Radiological Protection (ICRP). To determine whether the ICRP assertions concerning the similarity of the distributions of occupational risk at the higher risk levels (from non-radiation and from radiation work) to Canada a study of the high end of the distributions of non-radiological risk of occupational fatalities in the province of Ontario was performed. For the present study total doses from exposure to sources of ionizing radiation for Ontario workers were converted to relative risk rates to allow direct comparison with the non-radiological results. In addition, absolute values for the radiological risk rates (RRR) were derived. The radiological risk estimates are based on workers who work both from nuclear reactions and from X-rays. The conclusion is made that the radiological and non-radiological risk rate (NRRR) distributions are similar in shape, but the RRR are approximately 1 to 27 percent of the NRRR, depending on the industry concerned
BNL ALARA Center's development of a computerized radiological assessment and design system (RADS)
International Nuclear Information System (INIS)
Dionne, B.J.; Masciulli, S.; Connelly, J.M.
1993-01-01
The US Department of Energy's (DOE) Office of Health Physics and Industrial Hygiene sponsored a study of Radiological Engineering Programs at selected DOE contractor facilities. This study was conducted to review, evaluate, and summarize techniques and practices that should be considered in the design phase that reduce dose and the spread of radioactive materials during subsequent construction and operation of DOE radiological facilities. As in a previous study on operational ALARA programs, a variety of good-practice documents will be generated. It is envisioned that these documents will serve as a resource to assist radiological engineers in the process of designing radiological facilities, and in performing radiological safety/ALARA design reviews. This paper presents the features for three good-practice documents and related software applications that are being developed based on the findings of this study. The proposed software called Radiological Assessment and Design System (RADS) will be a menu-driven database and spreadsheet program. It will be designed to provide easy, consistent, and effective implementation of the methodologies described in the three good-practice documents. These documents and the associated RADS software will provide the user with the following three functions: (1) enter dose assessment information and data into computer worksheets and provide printed tables of the results which can then be inserted into safety analysis reports or cost-benefit analyses, (2) perform a wide variety of sorts of radiological design criteria from DOE Orders and produce a checklist of the desired design criteria, and (3) enter cost/benefit data and qualitative rating of attributes for various design alternatives which reduce dose into computer worksheets and provide printed reports of cost-effectiveness results
Patient exposure evaluation in Romanian radiological departments
International Nuclear Information System (INIS)
Girjoaba, O.; Cucu, A.
2012-01-01
Purpose: A nation-wide evaluation of ionizing radiation exposure of the Romanian population due to the radiological examinations is performed in accordance with European Directive 97/43 EURATOM implemented in national regulations. Method: The study is applied to the collected data from radiological departments from Romanian hospitals during 2010. The radiological examinations were grouped in three categories: conventional diagnostic radiology, interventional radiology and computed tomography. The annual collective dose was determined from the reported data about the mean effective doses and the frequency for each type of radiological examination, in conformity with the national regulations. Regarding the frequency aspects, the results include the age and gender distributions. Major results: More then 6 million radiological examinations were performed in 2010, Romania having a population about of 20.3 million inhabitants. The collective effective dose for 2010 resulted from the study is 152 mSv per 1000 inhabitants. Conclusions: Medical practitioners must select the best medical imaging investigation for each clinical case taking into account the importance of keeping the patient dose as low as possible. Medical physicists should be strongly involved in the establishing of the dosimetry procedures. (author)
AUTHOR|(CDS)2081300; Froeschl, Robert; Forkel-Wirth, Doris
CERN, the European Organization for Nuclear Research, operates high energy accelerators for particle physics research. Because of beam losses and subsequent particle interactions, radioactivity can be induced in certain accelerator components. Material and waste taken out of the accelerators facilities as a result of maintenance repair and upgrade actions as well as in case of decommissioning needs to be radiologically classied for future handling. Depending on the level of residual activity, some of these components are candidates for clearance from regulatory control in Switzerland. The Swiss radiation protection ordinance sets as criteria for clearance of material and waste from regulatory control the compliance with radionuclide specic limits for surface contamination and for specic activity as well as an ambient dose equivalent rate criterion. For objects with a mass below 1 kg a radionuclide specic clearance limit for total activity has to be respected. This work is focused on the specic activity criter...
International Nuclear Information System (INIS)
White, R.I. Jr.; Rizer, D.M.; Shuman, K.; White, E.J.; Adams, P.; Doyle, K.; Kinnison, M.
1987-01-01
During a 5-year period (1982-1987), 376 patients were admitted to an interventional radiology service where they were managed by the senior physician and interventional radiology fellows. Sixty-eight percent of patients were admitted for angioplasty and 32% for elective embolotherapy/diagnostic angiography. A one-half-day, twice weekly interventional radiology clinic and employment of a physician's assistant who performed preadmission history and physicals and wrote orders accounted, in part, for a decrease in hospital stay length from 3.74 days (1982-1983) to 2.41 days (1986-1987). The authors conclude that use of the clinic and the physician's assistant streamlines patient flow and the admitting process and is partially responsible for a decreased length of stay for patients admitted to an interventional radiology service
Global risks due to illicit trafficking of nuclear and radiological materials
International Nuclear Information System (INIS)
Barakat, M. F.
2012-01-01
The global widespread applications of of the peaceful uses of atomic energy resulted in the production and accumulation of huge amounts of dangerous nuclear wastes and nuclear materials, the greater part of which is left either unattended or insufficiently protected. In the mean time, many terrorist groups appeared in the international arena aiming at fighting against all forms of pressure, discrimination or injustice in the international relations among developed and developing countries particularly in politically unstable regions of the world. Unfortunately, these terrorist groups were inclined to adopt the use of nuclear or radiological rather crude weapons to improve their methods and efforts in imposing situations of maximum horror possible to subjected communities. In the present work a brief study of the dimensions of nuclear terrorism, its forms and means directed to its support , has been carried out. The efforts to combat against nuclear proliferation in Central Asia as a region in which most of the violations of the non proliferation efforts occurred has been treated. In contrast, the prevailing conditions and efforts in the Americas region are discussed being a region in which combined efforts of the united states with other American countries were rather successful in combating nuclear proliferation. Some recommendations have been given concerning the necessary measures to face the global risk of illicit trafficking of nuclear materials all over the world. (author)
Energy Technology Data Exchange (ETDEWEB)
Lopez V, J.; Capadona, N. [Autoridad Regulatoria Nuclear, Av. Del Libertador 8250 (1429) Buenos Aires, (Argentina)]. e-mail: jlvietri@sede.arn.gov.ar
2006-07-01
The present work has by objective to indicate rules for the establishment and the use of the Radiological Protection Programs (PPR) that are of application to the transport of radioactive materials according to that required by the Transport Regulation of the International Atomic Energy Agency (IAEA). The PPR are established and applied in systematic form for remittent, transport and addressees, to consider the measures of radiological protection and its appropriately control during the transport stages of radioactive material. In particular, in the work it is analyzed the PPR applied to the operative stage, in the one that can be considered as one of the more important documents to use since it summarizes the evaluations and the necessary controls of radiological protection. Also it is analyzed the importance that this document gets ready on the base that it converges in the the analyses, evaluations and data that have been kept in mind during the previous stages of design of bundles and production of packings, the types and quantities of involved bundles, as well as of considering the quantities of expeditions and its frequencies, the ways of transport, etc. It is included a brief description of the parts that the PPR conforms on the base of that suggested in the advanced draft of the TS-G-1.5 Guide 'Radiation Protection Programmes for Transport of Radioactive Material', of October, 2005, of the IAEA: objectives. necessity, scope, basic elements of a PPR in function of the occupational dose. assignment of functions and responsibilities for the establishment of a PPR, evaluation and dose optimization, surface contamination, segregation and other protection measures, responses in emergencies. training and administration systems for baled and transport of radioactive material. Next an example of PPR for the transport of bundles of the A Type by lorry with content of radiopharmaceuticals that are the bundles more used worldwide in the expeditions of
Aspects of radiological protection in nuclear installations
International Nuclear Information System (INIS)
Hunt, J.G.; Oliveira Filho, D.S.; Rabello, P.N.P.
1987-01-01
Due to the short term, long term and genetic effects of radiation, the work with radioactive materials requires special protection measures. The objective of radiological protection is to assure the occupational health of the workers by maintaining the dose levels as low as reasonably achievable. The radiological protection measures implanted in the NUCLEBRAS fuel element factory are described. The philosophy and practical measures taken are explained, and a comparison between radiation protection and industrial safety norms is made. The result of this work shows that the radiological safety of the element factory is assured. (author) [pt
Radiological protective screen
International Nuclear Information System (INIS)
Flaugnatti, R.B.
1976-01-01
A radiological screen for placing on a patient's skin is discussed, comprising a flat jacket containing a fine particulate filler and a settable resin binder, the fine particulate filler being of a material which absorbs medical radiation, and the jacket including a window to transmit such radiation through the flat jacket. 16 claims, 4 drawing figures
A cross-site vascular radiology on-call service: the Manchester experience
International Nuclear Information System (INIS)
Ashleigh, R.J.; Butterfield, J.S.; Asquith, J.; Chalmers, N.; Murphy, G.
2005-01-01
AIM: A cross-site vascular radiology on-call service was established 5 years ago to cover two vascular centres in Manchester. We aimed to review the service. MATERIALS AND METHODS: A prospective audit of out-of hours referrals and procedures over a three month period (March-May 2003) was undertaken. RESULTS: There were 52 incidents in 49 patients (mean 4 calls per week). Nine involved telephone advice only, the remainder (82%) required a procedure. Angiography was performed on 88% of patients and therapeutic radiological intervention on 50%. 71% of calls occurred at a weekend. 50% of the calls were from vascular surgery and 50% from other sources. The consultant vascular radiologist was present for 93% of procedures. CONCLUSIONS: The workload suggests that a vascular radiology on call service is justified in Manchester. There have been no major problems with its implementation and operation. This is a consultant led service, with very few cases being devolved to a specialist registrar (SpR)
International Nuclear Information System (INIS)
Reyes, R.; Scott, A.; Falo, G.; Collins, J.; Szrom, F.; Collins, D.
1999-01-01
Radiological assessment of sites with radioactive residues starts with the identification of potential sources. The US Army Center for Health Promotion and Preventive Medicine (USACHPPM) has developed a technical guide that summarizes sources of potential radiological exposures of both civilian and military origin. These sources include those found in the natural environment, in the nuclear fuel cycle, in medical and industrial settings, in the transportation of radioactive materials, in US Army commodities and foreign materiel, and in the use and storage of nuclear weapons. This technical guide is intended to foster awareness of radiological hazards and to provide the reader with the knowledge necessary to take the first step in radiological health risk assessment: recognition of the hazard. Furthermore, this guide can be used in conjunction with other technical guides for performing radiological surveys and field dose assessments in war or peacetime operations. (author)
Hazardous materials package performance regulations
International Nuclear Information System (INIS)
Russell, N.A.; Glass, R.E.; McClure, J.D.; Finley, N.C.
1992-01-01
The hazardous materials (hazmat) packaging development and certification process is currently defined by two different regulatory philosophies, one based on specification packagings and the other based on performance standards. With specification packagings, a packaging is constructed according to an agreed set of design specifications. In contrast, performance standards do not specify the packaging design; they specify performance standards that a packaging design must be able to pass before it can be certified for transport. The packaging can be designed according to individual needs as long as it meets these performance standards. Performance standards have been used nationally and internationally for about 40 years to certify radioactive materials (RAM) packagings. It is reasonable to state that for RAM transport, performance specifications have maintained transport safety. A committee of United Nation's experts recommended the performance standard philosophy as the preferred regulation method for hazmat packaging. Performance standards for hazmat packagings smaller than 118 gallons have been adopted in 49CFR178. Packagings for materials that are classified as toxic-by-inhalation must comply with the performance standards by October 1, 1993, and packagings for all other classes of hazardous materials covered must comply by October 1, 1996. For packages containing bulk (in excess of 188 gallons) quantities of materials that are extremely toxic by inhalation, there currently are no performance requirements. This paper discusses a Hazmat Packaging Performance Evaluation (HPPE) project to look at the subset of bulk packagings that are larger than 2000 gallons. The objectives of this project are the evaluate current hazmat specification packagings and develop supporting documentation for determining performance requirements for packagings in excess of 2000 gallons that transport hazardous materials that have been classified as extremely toxic by inhalation (METBI)
Directory of Open Access Journals (Sweden)
A َKalantari
2014-08-01
Full Text Available Background & aim: Radiology personnel’s working in terms of performance and safety is one of the most important functions in order to increase the quality and quantity. This study aimed to evaluate the radiological standards in Shahid Beheshti Hospital of Yasuj, Iran, in 2013. Methods: The present cross-sectional study was based on a 118 randomly selected graphs and the ranking list, with full knowledge of the standards in radiology was performed two times. Data were analyzed using descriptive statistics. Results: 87.3% of the students chose the cassette, 76.3%, patients chose the position, 87.3%, member state, the central ray 83.9%, and the distance between the tube and the patient 68.6% had been operated in accordance with the standards practice. Among all the factors and variables, between view with cassette, view with SID, sex with position patients, grid with central ray, grid with SID, Request with positioning the patient and between density with patient position and member position significant relationship were observed p<0.05 . Conclusions: Staff and students in terms of performance were at high levels, but in the levels of protection were in poor condition. Therefore, in order to promote their conservation, education and periodical monitoring should be carried out continuously.
Radiological Protection Miscellaneous Provisions Act 2014
International Nuclear Information System (INIS)
Irish Legislation
2014-07-01
This Act provides for the dissolution of the Radiological Protection Institute of Ireland and the transfer of all its functions, assets, liabilities and staff to the Environmental Protection Agency, to give effect to the Amendment to the Convention on the Physical Protection of Nuclear Material done at Vienna on 8 July 2005, to amend the Radiological Protection Act 1991, the Environmental Protection Agency Act 1992 and certain other enactments, and to provide for matters connected therewith
Post-deployment usability evaluation of a radiology workstation
Jorritsma, Wiard; Cnossen, Fokie; Dierckx, Rudi; Oudkerk, Matthijs; van Ooijen, Peter
2015-01-01
Objective To evaluate the usability of a radiology workstation after deployment in a hospital. Significance In radiology, it is difficult to perform valid pre-deployment usability evaluations due to the heterogeneity of the user group, the complexity of the radiological workflow, and the complexity
International Nuclear Information System (INIS)
Bundy, A.L.
1988-01-01
Radiologists rely upon the talents of the technologists with whom they work. Indeed, a good technologist will only enhance the radiologist's performance. Radiological technologists no longer solely take radiographs, but are involved in many more detailed areas of imaging, such as computered tomography, magnetic resonance imaging, nuclear radiology, ultrasound, angiography, and special procedures. They are also required to make decisions that affect the radiological examination. Besides the degree in radiological technology (RT), advanced degrees in nuclear medicine technology (NMT) and diagnostic medical sonography (RDMS) are attainable. The liability of the technologist is not the same as the radiologist involved, but the liability is potentially real and governed by a subdivision of jurisprudence known as agency law. Since plaintiffs and attorneys are constantly searching for new frontiers of medical liability, it is wise for the radiologist and technologist to be aware of the legalities governing their working relationship and to behave accordingly. The legal principles that apply to this working relationship are discussed in this chapter, followed by a presentation of some relevant and interesting cases that have been litigated
Radiological survey results at 4400 Piehl Road, Ottawa Lake, Michigan
International Nuclear Information System (INIS)
Foley, R.D.; Johnson, C.A.
1993-04-01
At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at 4400 Piehl Road in Ottawa Lake, Michigan. The survey was performed in September, 1992. The purpose of the survey was to determine if materials containing uranium from work performed under government contract at the former Baker Brothers facility in Toledo, Ohio had been transported off-site to this neighboring area. The radiological survey included surface gamma scans indoors and outdoors, alpha and beta scans inside the house and attached garage, beta-gamma scans of the hard surfaces outside, and the collection of soil, water, and dust samples for radionuclide analyses. Results of the survey demonstrated that the majority of the measurements on the property were within DOE guidelines. However, the presence of isolated spots of uranium contamination were found in two areas where materials were allegedly transported to the property from the former Baker Brothers site. Uranium uptake by persons on the property by ingestion is fairly unlikely, but inhalation is a possibility. Based on these findings, it is recommended that the residential property at 4400 Piehl Road in Ottawa Lake, Michigan be considered for inclusion under FUSRAP
Study of photoconductor-based radiological image sensors
International Nuclear Information System (INIS)
Beaumont, Francois
1989-01-01
Because of the evolution of medical imaging techniques to digital Systems, it is necessary to replace radiological film which has many drawbacks, by a detector quite as efficient and quickly giving a digitizable signal. The purpose of this thesis is to find new X-ray digital imaging processes using photoconductor materials such as amorphous selenium. After reviewing the principle of direct radiology and functions to be served by the X-ray sensor (i.e. detection, memory, assignment, visualization), we explain specification. We especially show the constraints due to the object to be radiographed (condition of minimal exposure), and to the reading signal (electronic noise detection associated with a reading frequency). As a result of this study, a first photoconductor sensor could be designed. Its principle is based on photo-carrier trapping at dielectric-photoconductor structure interface. The reading System needs the scanning of a laser beam upon the sensor surface. The dielectric-photoconductor structure enabled us to estimate the possibilities offered by the sensor and to build a complete x-ray imaging System. The originality of thermo-dielectric sensor, that was next studied, is to allow a thermal assignment reading. The chosen System consists in varying the ferroelectric polymer capacity whose dielectric permittivity is weak at room temperature. The thermo-dielectric material was studied by thermal or Joule effect stimulation. During our experiments, trapping was found in a sensor made of amorphous selenium between two electrodes. This new effect was performed and enabled us to expose a first interpretation. Eventually, the comparison of these new sensor concepts with radiological film shows the advantage of the proposed solution. (author) [fr
Pediatric radiology fellows' experience with intussusception reduction
International Nuclear Information System (INIS)
Stein-Wexler, Rebecca; Bateni, Cyrus; Wootton-Gorges, Sandra L.; Li, Chin-Shang
2011-01-01
Intussusception reduction allows young children to avoid surgery. However, graduating residents have had relatively little training in intussusception reduction and, for the most part, consider themselves ill-prepared to perform this procedure. The goal of this study was to assess the extent of training in intussusception reduction during one year of a pediatric radiology fellowship and to determine whether graduating fellows consider themselves adequately trained in this technique. Pediatric radiology fellows were surveyed during June 2010 and asked to characterize their fellowship, to indicate the number of intussusception reductions performed (both the total number and those performed with faculty oversight but without active faculty involvement), and to assess the adequacy of their training. There were 31 responses, representing almost 1/3 of current fellows. Pediatric radiology fellows perform on average 6.9 reductions, 3.8 of which are with faculty oversight but without active faculty involvement. Ninety percent consider themselves well-trained in the technique, whereas 10% are uncertain (none consider their training inadequate). Almost all pediatric radiology fellows consider their training in intussusception reduction to be adequate. (orig.)
Radioactive material packaging performance testing
International Nuclear Information System (INIS)
Romano, T.; Cruse, J.M.
1991-02-01
To provide uniform packaging of hazardous materials on an international level, the United Nations has developed packaging recommendations that have been implemented worldwide. The United Nations packaging recommendations are performance oriented, allowing for a wide variety of package materials and systems. As a result of this international standard, efforts in the United States are being directed toward use of performance-oriented packaging and elimination of specification (designed) packaging. This presentation will focus on trends, design evaluation, and performance testing of radioactive material packaging. The impacts of US Department of Transportation Dockets HM-181 and HM-169A on specification and low-specific activity radioactive material packaging requirements are briefly discussed. The US Department of Energy's program for evaluating radioactive material packings per US Department of Transportation Specification 7A Type A requirements, is used as the basis for discussing low-activity packaging performance test requirements. High-activity package testing requirements are presented with examples of testing performed at the Hanford Site that is operated by Westinghouse Hanford Company for the US Department of Energy. 5 refs., 2 tabs
Evaluation of medical radiation exposure in pediatric interventional radiology procedures
Energy Technology Data Exchange (ETDEWEB)
Navarro, Valeria Coelho Costa; Navarro, Marcus Vinicius Teixeira; Oliveira, Aline da Silva Pacheco, E-mail: vccnavarro@gmail.com [Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia (IFBA), Salvador, BA (Brazil); Maia, Ana Figueiredo [Universidade Federal de Sergipe (UFS), Aracaju, SE (Brazil); Oliveira, Adriano Dias Dourado [Sociedade Brasileira de Hemodinamica e Cardiologia Intervencionista, Salvador, BA (Brazil)
2012-07-15
Objective: To evaluate pediatric radiation exposure in procedures of interventional radiology in two hospitals in the Bahia state, aiming at contributing to delineate the scenario at the state and national levels. The knowledge of exposure levels will allow an evaluation of the necessity of doses optimization, considering that peculiarities of radiology and pediatrics become even more significant in interventional radiology procedures which involve exposure to higher radiation doses. Materials and Methods: A total of 32 procedures were evaluated in four rooms of the two main hospitals performing pediatric interventional radiology procedures in the Bahia state. Air kerma rate and kerma-area product were evaluated in 27 interventional cardiac and 5 interventional brain procedures. Results: Maximum values for air kerma rate and kerma-area product and air kerma obtained in cardiac procedures were, respectively, 129.9 Gy.cm{sup 2} and 947.0 mGy; and, for brain procedures were 83.3 Gy.cm{sup 2} and 961.0 mGy. Conclusion: The present study results showed exposure values up to 14 times higher than those found in other foreign studies, and approximating those found for procedures in adults. Such results demonstrate excessive exposure to radiation, indicating the need for constant procedures optimization and evaluation of exposure rates. (author)
Radiological protection challenges at B.N.G. Sellafield
International Nuclear Information System (INIS)
Hallard, R.; Anderson, B.; Hutton, E.
2006-01-01
The UK Nuclear Industry is in the midst of a period of intense change with the formation of a national body to manage the clean up of Nuclear facilities. Previous owners of nuclear sites have become contractors and the emphasis has switched from production facilities for power or reprocessing to decommissioning and clean up. Many of the older facilities were not designed for decommissioning and now require attention to reduce risks. Sellafield represents a microcosm of the industry with operating and production facilities, waste storage facilities and plants awaiting or undergoing decommissioning. The experience already gained in decommissioning of redundant facilities over the last decade is being used to develop an accelerated response to clean up of the past. The major challenge is to accommodate the changes whilst monitoring and improving Radiological standards and performance. This paper describes a number of issues to which the site must be managed to ensure that the current Radiological performance is maintained and improved. The dose control arrangements for some 6000 radiation workers on the site requires a change in approach as we move towards localised project based systems with an increasingly mobile workforce. Work is proceeding to introduce a new generation of short term dose control equipment with an emphasis on safety culture and management responsibilities for dose control. The achievement and demonstration of ALARP in these circumstances, is being reviewed in situations where timescale, overall risk to public and workforce and exposure to non radiological hazards are factors. Clean up requires more attention to clearance of materials and this aspect has an increasing profile to recognize the need to balance risk and expenditure. The paper will review the current Radiological Protection challenges to the changing Nuclear Industry using the Sellafield site as the prime example and will discuss achievements and areas where further work is necessary
Practical interventional radiology
International Nuclear Information System (INIS)
Lammer, J.; Schreyer, H.
1991-01-01
The book is intended as a practical guide and manual for interventional radiology applications. Main emphasis is placed on the performance of the various techniques, with explanations of the various steps to be taken, illustrated by drawings or pictures. Indications, contra-indications and clinical achievements are given in brief. There is one chapter each for the following techniques: angioplasty - intra-arterial fibrinolysis - vascular stents - neuroembolisation - embolisation of other vessels - biliary interventions - abscess drainage - nephrostomy and ureteral manipulations -percutaneous fine-needle biopsy - vena cava filters - interventional radiology in infants. (orig.)
BNL ALARA center's development of a computerized Radiological Assessment and Design System (RADS)
International Nuclear Information System (INIS)
Dionne, B.J.; Connelly, J.M.
1993-01-01
The US Department of Energy's (DOE) Office of Health Physics and Industrial Hygiene sponsored a study of Radiological Engineering Programs at selected DOE contractor facilities. This study was conducted to review, evaluate, and summarize techniques and practices that should be considered in the design phase that reduce dose and the spread of radioactive materials during subsequent construction and operation at DOE radiological facilities. As in a previous study on operational ALARA programs, a variety of open-quotes good-practice documentsclose quotes will be generated. It is envisioned that these documents will serve as a resource to assist radiological engineers in the process of designing radiological facilities, and in performing radiological safety/ALARA design reviews. This paper presents the features for three good-practice documents and related software applications that are being developed based on the findings of this study. The proposed software called open-quotes Radiological Assessment and Design Systemclose quotes (RADS) will be a menu-driven database and spreadsheet program. It will be designed to provide easy, consistent, and effective implementation of the methodologies described in the three good-practice documents. These documents and the associated RADS software will provide the user with the following three functions: (1) enter dose assessment information and data into computer worksheets and provide printed tables of the results which can then be inserted into safety analysis reports or cost-benefit analysis, (2) perform a wide variety of sorts of radiological design criteria from DOE Orders and produce a checklist of the desired design criteria, and (3) enter cost/benefit data and qualitative ratings of attributes for various design alternatives which reduce dose into computer worksheets and provide printed reports of cost-effectiveness results
International Nuclear Information System (INIS)
Donner, M.W.; Heuck, F.H.W.
1981-01-01
The book encompasses the proceedings of a postgraduate course held in Salzburg in June 1980. 230 radiologists from 17 countries discussed here the important and practical advances of diagnostic radiology, nuclear medicine and ultrasound as they contribute to gastrointestinal, urologic, skeletal, cardiovascular, pediatric, and neuroradiology. The book contains 55 single contributions of different authors to the following main themes: Cardiovascular, Radiology, pulmonary radiology, gastrointestinal radiology, urinary tract radiology, skeletal radiology, mammography, lymphography, ultrasound, ENT radiology, and neuroradiology. (orig./MG)
United States Department of Energy radiological emergency response programme - a national capability
International Nuclear Information System (INIS)
Gordon-Hagerty, L.E.
1993-01-01
In order to respond to a radiological emergency, the United States Department of Energy (USDOE) maintains seven emergency response assets and capabilities in support of a radiological emergency of any proportion within the continental United States and abroad. The seven emergency response assets and capabilities include: Accident Response Group; Aerial Measuring Systems; Atmospheric Release Advisory Capability; Federal Radiological Monitoring and Assessment Center; Nuclear Emergency Search Team; Radiation Emergency Assistance Center/Training Site; and Radiological Assistance Program. Presently, USDOE maintains the most comprehensive national radiological emergency response assets in the United States, capable of dealing with any type of emergency involving nuclear materials. In all, the Department's assets are available to support any type of accident/incident involving radioactive materials in coordination with other United States Federal agencies, as well as state and local governments, as required. (author)
Radiological aerial monitoring in a nuclear emergency
International Nuclear Information System (INIS)
Shin, Hyeongki; Kim, Juyoul; Jung, Gunhyo
2008-01-01
Since North Korea announced the underground nuclear test on last October 9th, 2006, many countries around the world have worried about the atmospheric dispersion and pollution of radioactive materials crossing the border by the clandestine nuclear test. After that time, verifying the existence of nuclear test by detecting radioactive materials such as xenon, I-131, and Cs-134 at the early stage of radiological emergency, locating the position of test site by backward trajectory analysis, and chasing the moving path of airborne radionuclide have been heavily issued. And collection of airborne radioactivity and gamma radiation monitoring technology using an aircraft have been recently examined by an authority concerned in South Korea. Although various techniques of radiological aerial monitoring have been developed and operated around the world, the relevant technical development or research is still required. In order to decide potential measuring location and time within the framework of radiological monitoring system, we use HYSPLIT (Hybrid Single Particle Lagrangian Integrated Trajectory) model developed by National Oceanic and Atmospheric Administration (NOAA) of U.S. Department of Commerce. The model is validated and assessed against North Korea's nuclear test. Calculation results of radionuclide trajectory show a good agreement with measured values. Backward trajectory analysis is useful to track the radiological source term, possible time and place of nuclear accidents and/or activities. Nationwide early warning system using aircraft and atmospheric dispersion model can help a nearly real-time forecasting and warning in preparation for radiological emergencies. (author)
Radiological field survey problems and solutions
International Nuclear Information System (INIS)
Deming, E.J.; Boerner, A.J.
1986-01-01
Situations often arise during radiological field surveys which require the health physicist to improvise and/or make spot decisions. At times these situations can be humorous, but they can also present hazards more serious than normal radiological considerations. This presentation will depict various problematic situations encountered by Oak Ridge Associated Universities Radiological Site Assessment Program in the course of performing field environmental surveys. Detailing these potential hazards can alert other field survey groups to problems they may encounter
Radiology and the Internet: A systematic review of patient information resources
Energy Technology Data Exchange (ETDEWEB)
Smart, James M; Burling, David
2001-11-01
AIM: To determine whether the internet is a useful resource for patients seeking information on radiological procedures. MATERIALS AND METHODS: A systematic search of the world wide web was performed by means of four general search engines (AltaVista, Yahoo{exclamation_point}, Infoseek and Excite). Twenty-eight suitable patient-directed websites on arteriography were identified for analysis. The value of this material was measured by establishing inclusion or exclusion of a number of factors relating to the procedure. Readability of the materials was evaluated using the Flesch reading ease score. RESULTS: Advice on preparation was included in 21 (75%) sites. Contraindications were found in 16 (57%) sites, risks in 6 (21%) and aftercare in 25 (89%). Result availability was discussed in 15 (54%) sites, with links to other radiology sites in 13 (46%). Visual aids were used in 6 (21%) sites and a contact address found in 27 (96%). Mean Flesch reading ease score was 57, with 46% of sites below the preferred minimum of 60. CONCLUSIONS: Few sites provide the range of information a patient needs before arriving for a procedure. In addition, the readability of the material on these sites is frequently set at a level incomprehensible to patients with lower levels of literacy. Smart, J.M. and Burling, D. (2001)
Radiology and the Internet: A systematic review of patient information resources
International Nuclear Information System (INIS)
Smart, James M.; Burling, David
2001-01-01
AIM: To determine whether the internet is a useful resource for patients seeking information on radiological procedures. MATERIALS AND METHODS: A systematic search of the world wide web was performed by means of four general search engines (AltaVista, Yahoo!, Infoseek and Excite). Twenty-eight suitable patient-directed websites on arteriography were identified for analysis. The value of this material was measured by establishing inclusion or exclusion of a number of factors relating to the procedure. Readability of the materials was evaluated using the Flesch reading ease score. RESULTS: Advice on preparation was included in 21 (75%) sites. Contraindications were found in 16 (57%) sites, risks in 6 (21%) and aftercare in 25 (89%). Result availability was discussed in 15 (54%) sites, with links to other radiology sites in 13 (46%). Visual aids were used in 6 (21%) sites and a contact address found in 27 (96%). Mean Flesch reading ease score was 57, with 46% of sites below the preferred minimum of 60. CONCLUSIONS: Few sites provide the range of information a patient needs before arriving for a procedure. In addition, the readability of the material on these sites is frequently set at a level incomprehensible to patients with lower levels of literacy. Smart, J.M. and Burling, D. (2001)
Changes in IEC standards related to diagnostic radiology
International Nuclear Information System (INIS)
Porubszky, T.; Barsai, J.
2007-01-01
Complete test of publication follows. Purposes. Technical Committee TC62 of International Electrotechnical Commission (IEC) deals with medical electrical equipment (i.e. medical devices using electricity). Standardization concerning diagnostic radiology equipment is task of its Sub-Committee SC62B. An outlook of its activities and present situation, and especially of radiation protection aspects, is given. Materials and methods. Third edition of basic safety standard for medical electrical equipment IEC 60601-1 was issued in 2005. Elaboration of new collateral and particular standards - applicable together with it - is in progress. These standards are generally at the same time also European - EN - and national standards. There is a great importance of radiation protection in diagnostic X-ray equipment. Collateral standard IEC 6060-1-3 about it was at first issued in 1994. Rapid development of imaging technology demands updating of requirements. SC62B in 2003 founded a maintenance team MT37 for preparation of the second edition of this standard. According to new safety philosophy of IEC all modality specific requirements are to be collected in 'safety and essential performance' particular standards. A new working group WG42 - founded in 2006 - elaborates a new particular standard IEC 60601-2-54 for radiographic and radioscopic equipment. Maintenance team MT32 deals with safety and performance standards for X-ray tube assemblies. The authors actively participate in these activities. Results and discussion. Present and future system of diagnostic radiology IEC standards and some interesting details are presented. Conclusions. International standards - although they are not 'obligatory' - are generally the basis of safety and performance certification of diagnostic radiology equipment and often also of their quality assurance.
Pediatric digital radiography education for radiologic technologists: current state
International Nuclear Information System (INIS)
Morrison, Gregory; Culbertson, John; Carbonneau, Kira; John, Susan D.; Goske, Marilyn J.; Smith, Susan N.; Charkot, Ellen; Herrmann, Tracy
2011-01-01
Digital radiography (DR) is one of several new products that have changed our work processes from hard copy to digital formats. The transition from analog screen-film radiography to DR requires thorough user education because of differences in image production, processing, storage and evaluation between the forms of radiography. Without adequate education, radiologic technologists could unknowingly expose children to higher radiation doses than necessary for adequate radiograph quality. To evaluate knowledge about image quality and dose management in pediatric DR among radiologic technologists in the U.S. This communication describes a survey of 493 radiologic technologists who are members of the American Society of Radiologic Technologists (ASRT) and who evaluated the current state of radiological technologist education in image quality and dose management in pediatric DR. The survey included 23 survey questions regarding image acquisition issues, quality assurance, radiation exposure and education in DR of infants and children. Radiologic technologists express many needs in areas of training and education in pediatric DR. Suggested improvements include better tools for immediate feedback about image quality and exposure, more information about appropriate technique settings for pediatric patients, more user-friendly vendor manuals and educational materials, more reliable measures of radiation exposure to patients, and more regular and frequent follow-up by equipment vendors. There is a clear and widespread need for comprehensive and practical education in digital image technology for radiologic technologists, especially those engaged in pediatric radiography. The creation of better educational materials and training programs, and the continuation of educational opportunities will require a broad commitment from equipment manufacturers and vendors, educational institutions, pediatric radiology specialty organizations, and individual imaging specialists. (orig.)
Radiological Work Planning and Procedures
Kurtz, J E
2000-01-01
Each facility is tasked with maintaining personnel radiation exposure as low as reasonably achievable (ALARA). A continued effort is required to meet this goal by developing and implementing improvements to technical work documents (TWDs) and work performance. A review of selected TWDs from most facilities shows there is a need to incorporate more radiological control requirements into the TWD. The Radioactive Work Permit (RWP) provides a mechanism to place some of the requirements but does not provide all the information needed by the worker as he/she is accomplishing the steps of the TWD. Requiring the engineers, planners and procedure writers to put the radiological control requirements in the work steps would be very easy if all personnel had a strong background in radiological work planning and radiological controls. Unfortunately, many of these personnel do not have the background necessary to include these requirements without assistance by the Radiological Control organization at each facility. In add...
SHIELD 1.0: development of a shielding calculator program in diagnostic radiology
International Nuclear Information System (INIS)
Santos, Romulo R.; Real, Jessica V.; Luz, Renata M. da; Friedrich, Barbara Q.; Silva, Ana Maria Marques da
2013-01-01
In shielding calculation of radiological facilities, several parameters are required, such as occupancy, use factor, number of patients, source-barrier distance, area type (controlled and uncontrolled), radiation (primary or secondary) and material used in the barrier. The shielding design optimization requires a review of several options about the physical facility design and, mainly, the achievement of the best cost-benefit relationship for the shielding material. To facilitate the development of this kind of design, a program to calculate the shielding in diagnostic radiology was implemented, based on data and limits established by National Council on Radiation Protection and Measurements (NCRP) 147 and SVS-MS 453/98. The program was developed in C⌗ language, and presents a graphical interface for user data input and reporting capabilities. The module initially implemented, called SHIELD 1.0, refers to calculating barriers for conventional X-ray rooms. The program validation was performed by the comparison with the results of examples of shielding calculations presented in NCRP 147.
Radiological characterisation - Know your objective
International Nuclear Information System (INIS)
Lindow, Veronica; Moeller, Jennifer
2012-01-01
When developing a programme for mapping the radiological characteristics of a facility to be decommissioned it is important to take into account the objectives of the programme. Will the results be used to plan for radiological control and selection of appropriate decontamination and dismantling techniques? Will the radiological inventory be used for dimensioning of future waste repositories? These are two examples of the applications for such studies, which could require that a radiological characterisation programme be adapted to provide the data appropriate to the intended use. The level of detail and scope needed for a radiological characterisation will also vary depending on how the data will be used. An application to free-release a facility requires a comprehensive survey and well documented analysis in order to ensure that no radioactive contamination above prescribed levels is present. A bounding calculation to determine the maximum anticipated volumes and activity of radioactive waste requires a different approach. During the past few years, older decommissioning studies for the Swedish nuclear power plants have been updated (or are in the process of being updated). The decommissioning study's main purpose is to estimate the cost for decommissioning. The cost estimation is based on material and activity inventories, which in turn is based on previous and, in some cases, updated radiological characterisations of the facilities. The radiological inventory is an important part of the study as it affects the cost of decommissioning but also the uncertainties and accuracy of the cost estimation. The presentation will discuss the challenges in specifying a radiological characterisation programme with multiple objectives, together with insights on how data delivered can be applied to yield results suitable for the intended purpose, without introducing excessive conservatism. The intent of the presentation is to define issues that can be of use in various aspects
RadMAP: The Radiological Multi-sensor Analysis Platform
International Nuclear Information System (INIS)
Bandstra, Mark S.; Aucott, Timothy J.; Brubaker, Erik; Chivers, Daniel H.; Cooper, Reynold J.; Curtis, Joseph C.; Davis, John R.; Joshi, Tenzing H.; Kua, John; Meyer, Ross; Negut, Victor; Quinlan, Michael; Quiter, Brian J.; Srinivasan, Shreyas; Zakhor, Avideh; Zhang, Richard; Vetter, Kai
2016-01-01
The variability of gamma-ray and neutron background during the operation of a mobile detector system greatly limits the ability of the system to detect weak radiological and nuclear threats. The natural radiation background measured by a mobile detector system is the result of many factors, including the radioactivity of nearby materials, the geometric configuration of those materials and the system, the presence of absorbing materials, and atmospheric conditions. Background variations tend to be highly non-Poissonian, making it difficult to set robust detection thresholds using knowledge of the mean background rate alone. The Radiological Multi-sensor Analysis Platform (RadMAP) system is designed to allow the systematic study of natural radiological background variations and to serve as a development platform for emerging concepts in mobile radiation detection and imaging. To do this, RadMAP has been used to acquire extensive, systematic background measurements and correlated contextual data that can be used to test algorithms and detector modalities at low false alarm rates. By combining gamma-ray and neutron detector systems with data from contextual sensors, the system enables the fusion of data from multiple sensors into novel data products. The data are curated in a common format that allows for rapid querying across all sensors, creating detailed multi-sensor datasets that are used to study correlations between radiological and contextual data, and develop and test novel techniques in mobile detection and imaging. In this paper we will describe the instruments that comprise the RadMAP system, the effort to curate and provide access to multi-sensor data, and some initial results on the fusion of contextual and radiological data.
RadMAP: The Radiological Multi-sensor Analysis Platform
Energy Technology Data Exchange (ETDEWEB)
Bandstra, Mark S., E-mail: msbandstra@lbl.gov [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Aucott, Timothy J. [Department of Nuclear Engineering, University of California Berkeley, CA (United States); Brubaker, Erik [Sandia National Laboratory, Livermore, CA (United States); Chivers, Daniel H.; Cooper, Reynold J. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Curtis, Joseph C. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Department of Nuclear Engineering, University of California Berkeley, CA (United States); Davis, John R. [Department of Nuclear Engineering, University of California Berkeley, CA (United States); Joshi, Tenzing H.; Kua, John; Meyer, Ross; Negut, Victor; Quinlan, Michael; Quiter, Brian J. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Srinivasan, Shreyas [Department of Nuclear Engineering, University of California Berkeley, CA (United States); Department of Electrical Engineering and Computer Science, University of California Berkeley, CA (United States); Zakhor, Avideh; Zhang, Richard [Department of Electrical Engineering and Computer Science, University of California Berkeley, CA (United States); Vetter, Kai [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Department of Nuclear Engineering, University of California Berkeley, CA (United States)
2016-12-21
The variability of gamma-ray and neutron background during the operation of a mobile detector system greatly limits the ability of the system to detect weak radiological and nuclear threats. The natural radiation background measured by a mobile detector system is the result of many factors, including the radioactivity of nearby materials, the geometric configuration of those materials and the system, the presence of absorbing materials, and atmospheric conditions. Background variations tend to be highly non-Poissonian, making it difficult to set robust detection thresholds using knowledge of the mean background rate alone. The Radiological Multi-sensor Analysis Platform (RadMAP) system is designed to allow the systematic study of natural radiological background variations and to serve as a development platform for emerging concepts in mobile radiation detection and imaging. To do this, RadMAP has been used to acquire extensive, systematic background measurements and correlated contextual data that can be used to test algorithms and detector modalities at low false alarm rates. By combining gamma-ray and neutron detector systems with data from contextual sensors, the system enables the fusion of data from multiple sensors into novel data products. The data are curated in a common format that allows for rapid querying across all sensors, creating detailed multi-sensor datasets that are used to study correlations between radiological and contextual data, and develop and test novel techniques in mobile detection and imaging. In this paper we will describe the instruments that comprise the RadMAP system, the effort to curate and provide access to multi-sensor data, and some initial results on the fusion of contextual and radiological data.
Attention for pediatric interventional radiology
International Nuclear Information System (INIS)
Zhu Ming; Cheng Yongde
2005-01-01
Radiological interventions possess wide utilization in the diagnosis and treatment for pediatric patients. Pediatric interventional radiology is an important branch of interventional radiology and also an important branch of pediatric radiology. Pediatric interventional radiology has grown substantially over the last 30 years, radiologists closely cooperation with surgeons and other physicians providing a new horizon in the management of pediatric diseases in western countries. It includes pediatric cardiac interventional radiology, pediatric neuro-interventional radiology, pediatric vascular interventional radiology, pediatric nonvascular interventional radiology, pediatric tumor interventional radiology and others. In the United States, every children hospital which owns two hundred beds has to have special trained interventional radiologists in radiologic department installing with advanced digital subtraction angiographic equipment. Interventional therapeutic procedures and diagnostic angiography have been proceeding more and more for the congenital and acquired diseases of children. The promising results give use uprising and interventional therapy as an alternative or a replacement or supplement to surgical operation. Pediatric interventional radiology is rather underdeveloped in China with a few special pediatric interventional radiologist, lack of digital subtraction angiography equipment. Pediatric radiologists have no enough field for interventional procedures such as pediatric neuro-interventional radiology and pediatric vascular interventional radiology. In the contrary adult interventional radiologists do have better interventional jobs in China and Pediatric cardiologists also share the same trend. They perform angiocardiography for congenital heart diseases and treat congenital heart disease with interventional procedures including balloon dilation of valves and vessels, coil embolization of collaterals, patent ducts and other arterial fistulae
The Radiological Research Accelerator Facility
International Nuclear Information System (INIS)
Hall, E.J.
1992-05-01
The Radiological Research Accelerator Facility (RARAF) is based on a 4-MV Van de Graaff accelerator, which is used to generate a variety of well-characterized radiation beams for research in radiobiology, radiological physics, and radiation chemistry. It is part of the Center for Radiological Research (CRR) -- formerly the Radiological Research Laboratory (RRL) -- of Columbia University, and its operation is supported as a National Facility by the US Department of Energy (DOE). As such, RARAF is available to all potential users on an equal basis, and scientists outside the CRR are encouraged to submit proposals for experiments at RARAF. The operation of the Van de Graaff is supported by the DOE, but the research projects themselves must be supported separately. Experiments performed from May 1991--April 1992 are described
Radiological assessment. A textbook on environmental dose analysis
Energy Technology Data Exchange (ETDEWEB)
Till, J.E.; Meyer, H.R. (eds.)
1983-09-01
Radiological assessment is the quantitative process of estimating the consequences to humans resulting from the release of radionuclides to the biosphere. It is a multidisciplinary subject requiring the expertise of a number of individuals in order to predict source terms, describe environmental transport, calculate internal and external dose, and extrapolate dose to health effects. Up to this time there has been available no comprehensive book describing, on a uniform and comprehensive level, the techniques and models used in radiological assessment. Radiological Assessment is based on material presented at the 1980 Health Physics Society Summer School held in Seattle, Washington. The material has been expanded and edited to make it comprehensive in scope and useful as a text. Topics covered include (1) source terms for nuclear facilities and Medical and Industrial sites; (2) transport of radionuclides in the atmosphere; (3) transport of radionuclides in surface waters; (4) transport of radionuclides in groundwater; (5) terrestrial and aquatic food chain pathways; (6) reference man; a system for internal dose calculations; (7) internal dosimetry; (8) external dosimetry; (9) models for special-case radionuclides; (10) calculation of health effects in irradiated populations; (11) evaluation of uncertainties in environmental radiological assessment models; (12) regulatory standards for environmental releases of radionuclides; (13) development of computer codes for radiological assessment; and (14) assessment of accidental releases of radionuclides.
Radiological assessment. A textbook on environmental dose analysis
International Nuclear Information System (INIS)
Till, J.E.; Meyer, H.R.
1983-09-01
Radiological assessment is the quantitative process of estimating the consequences to humans resulting from the release of radionuclides to the biosphere. It is a multidisciplinary subject requiring the expertise of a number of individuals in order to predict source terms, describe environmental transport, calculate internal and external dose, and extrapolate dose to health effects. Up to this time there has been available no comprehensive book describing, on a uniform and comprehensive level, the techniques and models used in radiological assessment. Radiological Assessment is based on material presented at the 1980 Health Physics Society Summer School held in Seattle, Washington. The material has been expanded and edited to make it comprehensive in scope and useful as a text. Topics covered include (1) source terms for nuclear facilities and Medical and Industrial sites; (2) transport of radionuclides in the atmosphere; (3) transport of radionuclides in surface waters; (4) transport of radionuclides in groundwater; (5) terrestrial and aquatic food chain pathways; (6) reference man; a system for internal dose calculations; (7) internal dosimetry; (8) external dosimetry; (9) models for special-case radionuclides; (10) calculation of health effects in irradiated populations; (11) evaluation of uncertainties in environmental radiological assessment models; (12) regulatory standards for environmental releases of radionuclides; (13) development of computer codes for radiological assessment; and (14) assessment of accidental releases of radionuclides
Radiological chronometry of uranium metal samples
International Nuclear Information System (INIS)
Meyers, L.A.; Stalcup, A.M.; Glover, S.E.; Spitz, H.B.; LaMont, S.P.
2014-01-01
Radiological chronometry is an important tool in nuclear forensics that uses several methods to determine the length of time that has elapsed since a material was last purified. One of the chronometers used in determining the age of metallic uranium involves measuring the fractional ingrowth of 230 Th from its parent 234 U with the assumption that the uranium metal contained no impurities, especially thorium, when it was purified. The affects of different etching procedures were evaluated for the removal of surface oxidation with three different types of uranium metal samples to determine whether the etching procedure affects the radiological age. The sample treated with a rigorous etching procedure had exhibited the most reliable radiological age while less rigorous etching yields a radiological age from 15 years to hundreds of years older than the known age. Any excess thorium on the surface of a uranium metal sample presents a bias in age determination and the sample will appear older than the true age. Although this research demonstrates the need for rigorous surface etching, a bias in the radiological age could have arisen if the uranium in the metal was heterogeneously distributed. (author)
Directory of Open Access Journals (Sweden)
Karami
2016-04-01
Full Text Available Background Gonad shielding is one of the fundamental methods by which to protect reproductive organs in patients undergoing conventional radiological examinations. A lack of or inadequate shielding of the gonads may increase the exposure of these organs and result in malignancies future generations. Objectives The aim of this study is to investigate the prevalence of gonad shielding in patients undergoing conventional radiological examinations and the availability of gonad shields and gonad shielding protocols in radiology departments. Materials and Methods A retrospective, observational cross-sectional study on the application of gonad shielding, the availability of gonad shields and the existence of gonad shielding protocols in radiology departments was performed in five different hospitals in Ahvaz, Iran. Results The highest application of gonad shielding was 6.6% for the pediatric hospital. The prevalence of gonad shielding was less than 0.2%. In 64.3% of the radiography rooms, at least one flat-contact gonad shield of a large size was available. Only large-sized gonad shields were available. Curved-contact and shadow gonad shields did not exist. Gonad shielding protocols were not existence in any of the fourteen radiography rooms investigated. Conclusions Comprehensive protection programs with on-the-job training courses for staff members are strongly recommended, as well as, the provision of radiological shields and gonad shielding protocols in radiology departments to reduce the patient’s radiation dose during radiological examinations.
Radiologic and clinical bronchiectasis associated with autosomal dominant polycystic kidney disease.
Directory of Open Access Journals (Sweden)
Teng Moua
Full Text Available BACKGROUND: Polycystin 1 and 2, the protein abnormalities associated with autosomal dominant polycystic kidney disease (ADPKD, are also found in airway cilia and smooth muscle cells. There is evidence of increased radiologic bronchiectasis associated with ADPKD, though the clinical and functional implications of this association are unknown. We hypothesized an increased prevalence of both radiologic and clinical bronchiectasis is associated with APDKD as compared to non-ADPKD chronic kidney disease (CKD controls. MATERIALS AND METHODS: A retrospective case-control study was performed at our institution involving consecutive ADPKD and non-ADPKD chronic kidney disease (CKD patients seen over a 13 year period with both chest CT and PFT. CTs were independently reviewed by two blinded thoracic radiologists. Manually collected clinical data included symptoms, smoker status, transplant history, and PFT findings. RESULTS: Ninety-two ADPKD and 95 non-ADPKD CKD control patients were compared. Increased prevalence of radiologic bronchiectasis, predominantly mild lower lobe disease, was found in ADPKD patients compared to CKD control (19 vs. 9%, P = 0.032, OR 2.49 (CI 1.1-5.8. After adjustment for covariates, ADPKD was associated with increased risk of radiologic bronchiectasis (OR 2.78 (CI 1.16-7.12. Symptomatic bronchiectasis occurred in approximately a third of ADPKD patients with radiologic disease. Smoking was associated with increased radiologic bronchiectasis in ADPKD patients (OR 3.59, CI 1.23-12.1. CONCLUSIONS: Radiological bronchiectasis is increased in patients with ADPKD particularly those with smoking history as compared to non-ADPKD CKD controls. A third of such patients have symptomatic disease. Bronchiectasis should be considered in the differential in ADPKD patients with respiratory symptoms and smoking history.
Pediatric radiology for medical-technical radiology assistants/radiologists
International Nuclear Information System (INIS)
Oppelt, Birgit
2010-01-01
The book on pediatric radiology includes the following chapter: differences between adults and children; psycho-social aspects concerning the patient child in radiology; relevant radiation doses in radiology; help for self-help: simple phantoms for image quality estimation in pediatric radiology; general information; immobilization of the patient; pediatric features for radiological settings; traumatology; contrast agents; biomedical radiography; computerized tomography; NMR imaging; diagnostic ultrasonography; handling of stress practical recommendations; medical displays.
Risk communication and radiological/nuclear terrorism: a strategic view.
Becker, Steven M
2011-11-01
It is now widely recognized that effective communication is a crucial element in radiological/nuclear terrorism preparedness. Whereas in the past, communication and information issues were sometimes viewed as secondary in comparison with technical concerns, today the need to improve risk communication, public information, and emergency messaging is seen as a high priority. The process of improving radiological/nuclear terrorism risk communication can be conceptualized as occurring in four overlapping phases. The first phase involves the recognition that communication and information issues will be pivotal in shaping how a radiological/nuclear terrorism incident unfolds and in determining its outcome. This recognition has helped shape the second phase, in which various research initiatives have been undertaken to provide an empirical basis for improved communication. In the third and most recent phase, government agencies, professional organizations and others have worked to translate research findings into better messages and informational materials. Like the first and second phases, the third phase is still unfolding. The fourth phase in risk communication for radiological/nuclear terrorism-a mature phase-is only now just beginning. Central to this phase is a developing understanding that for radiological/nuclear terrorism risk communication to be fully effective, it must go beyond crafting better messages and materials (as essential as that may be). This emerging fourth phase seeks to anchor radiological/nuclear communication in a broader approach: one that actively engages and partners with the public. In this article, each of the four stages is discussed, and future directions for improving radiological/nuclear terrorism risk communication are explored.
International Nuclear Information System (INIS)
Samuels, W.D.; Camaioni, D.M.; Babad, H.
1994-01-01
The underground storage tanks at the Hanford Complex contain wastes generated over many years from plutonium production and recovery processes, and mixed wastes from radiological degradation processes. The chemical changes of the organic materials used in the extraction processes have a direct bearing on several specific safety issues, including potential energy releases from these tanks. The major portion of organic materials that have been added to the tanks consists of tributyl phosphate, dibutyl phosphate, butyl alcohol, hexone (methyl isobutyl ketone), normal paraffin hydrocarbons (NPH), ethylenediaminetetraacetic acid (EDTA), hydroxyethylethylenediaminetriadetic acid (HEDTA), other complexants, and lesser quantities of ion exchange polymers and minor organic compounds. A study of how thermal and radiological processes that may have changed the composition of organic tanks constituents has been initiated after a review of the open literature revealed little information was available about the rates and products of these processes under basic pH conditions. This paper will detail the initial findings as they relate to gas generation, e.g. H 2 , CO, NH 3 , CH 4 , and to changes in the composition of the organic and inorganic components brought about by ''Aging'' processes
A radiological control implementation guide
International Nuclear Information System (INIS)
Hamley, S.A.
1993-01-01
A manual is being developed to explain to line managers how radiological controls are designed and implemented. The manual also fills a gap in the Health Physics literature between textbooks and on-the-floor procedures. It may be helpful to new Health Physicists with little practical experience and to those wishing to improve self-assessment, audit, and appraisal processes. Many audits, appraisals, and evaluations have indicated a need for cultural change, increased vigor and example, and more effective oversight by line management. Inadequate work controls are a frequent and recurring problem identified in occurrence reports and accident investigations. Closer study frequently indicates that many line managers are willing to change and want to achieve excellence, but no effective guidance exists that will enable them to understand and implement a modern radiological control program. The manual is now in draft form and includes information that will be of use to line managers dealing with improving radiological performance and the practical aspects of radiological controls implementation. The manual is expected to be completed by the fall of 1993 and to be used in conjunction with a performance-based self-assessment training program at the Oak Ridge National Laboratory
International Nuclear Information System (INIS)
Stieve, F.E.; Stargardt, A.; Stender, H.S.
1996-01-01
The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe) [de
Radiological bile acid absorption test {sup 75}SeHCAT in patients with diarrhoea of unknown cause
Energy Technology Data Exchange (ETDEWEB)
Rudberg, U. [St. Goeran`s Hospital, Stockholm (Sweden). Dept. of Diagnostic Radiology; Nylander, B. [St. Goeran`s Hospital, Stockholm (Sweden). Dept. of Internal Medicine
1996-09-01
Purpose: The purpose with this study was to investigate the usefulness of the {sup 75}SeHCAT test in patients suffering from `functional` diarrhoea and to disclose earlier radiological investigations performed in the course of disease. Material and Methods: Twenty patients with chronic diarrhoea of unknown cause were investigated with the {sup 75}SeHCAT test. The cholestyramine test and an estimation of oro-caecal transit time (OCTT) were also performed in 13 and 10 patients respectively. Results: Ten patients had low 7-day retention ({<=}15%). Nine of these were tested with cholestyramine and 8 showed complete relief from the diarrhoea. The cholestyramine test had no effect on the 4 patients with normal bile acid retention. No correlation was found between the retention of {sup 75}SeHCAT and OCCT. A total of 80 inconclusive gastrointestinal barium examinations were performed during the course of disease. Conclusion: Pathological bile acid retention, studied with the radiological {sup 75}SeHCAT test, is common in patients with diarrhoea of unknown cause. The test should be performed earlier in the course of disease in order to prevent unnecessary radiological investigations and to reduce patient suffering and distress. (orig.).
MTR radiological database for SRS spent nuclear fuel facilities
International Nuclear Information System (INIS)
Blanchard, A.
2000-01-01
A database for radiological characterization of incoming Material Test Reactor (MTR) fuel has been developed for application to the Receiving Basin for Offsite Fuels (RBOF) and L-Basin spent fuel storage facilities at the Savannah River Site (SRS). This database provides a quick quantitative check to determine if SRS bound spent fuel is radiologically bounded by the Reference Fuel Assembly used in the L-Basin and RBOF authorization bases. The developed database considers pertinent characteristics of domestic and foreign research reactor fuel including exposure, fuel enrichment, irradiation time, cooling time, and fuel-to-moderator ratio. The supplied tables replace the time-consuming studies associated with authorization of SRS bound spent fuel with simple hand calculations. Additionally, the comprehensive database provides the means to overcome resource limitations, since a series of simple, yet conservative, hand calculations can now be performed in a timely manner and replace computational and technical staff requirements
Preventing radiological threat in the Republic of Azerbaijan
International Nuclear Information System (INIS)
Gabulov, I.A.
2005-01-01
Full text: Azerbaijan is a developing and transit country in the Caucasus, connecting East and West. In addition, Azerbaijan is neighboring countries with pronounced political instability, some of which have extensive nuclear infrastructure or try to develop nuclear infrastructure. Furthermore, in the recent past fundamentalist religious terrorism has taken roots in some of these countries. Therefore, in spite of the fact that the Republic of Azerbaijan has no nuclear facilities or nuclear materials in its own territory, it could be interesting for terrorist groups trying to develop a crude radiological dispersal device using radioactive sources that are widely used in everyday life especially in such areas as oil industry, medicine, agriculture and scientific researches. The issues of reduction and prevention of both radiological and nuclear terrorism threat are one of the main global challenges around the world. The Republic of Azerbaijan is a part of world community and so we are concerned that radioactive sources used for peaceful applications could be stolen by the terrorist groups and used in the development of radiological dispersal devices sometimes referred to as a 'dirty bomb'. It is obvious that using highly radioactive materials in radiological dispersal devices could be very disruptive to society, causing panic, environmental contamination, and large financial losses. One of the ways for reduction and prevention of radiological threat for the countries like Azerbaijan with underdeveloped nuclear security and radiation safety infrastructure is closely participation in the international cooperation programs. As an example of such cooperation, I would like to present the United States Department of Energy's International Radiological Threat Reduction (IRTR) Program. Good progress has made in the field of radiological security within the framework of this program that was started 2003. Actually, in comparison with any IAEA programs, the progress reached by
ASTM reference radiologic digital image standards
International Nuclear Information System (INIS)
Wysnewski, R.; Wysnewski, D.
1996-01-01
ASTM Reference Radiographs have been essential in defining industry's material defect grade levels for many years. ASTM Reference Radiographs are used extensively as even the American Society for Metals Nondestructive Inspection and Quality Control Metals Handbook, Volume 11, eighth edition refers to ASTM Standard Reference Radiographs. The recently published E 1648 Standard Reference Radiographs for Examination of Aluminum Fusion Welds is a prime example of the on-going need for these references. To date, 14 Standard Reference Radiographs have been published to characterize material defects. Standard Reference Radiographs do not adequately address film-less radiologic methods. There are differences in mediums to content with. On a computer CRT defect indications appear differently when compared to indications viewed in a radiograph on a view box. Industry that uses non-film radiologic methods of inspection can be burdened with additional time and money developing internal standard reference radiologic images. These references may be deemed necessary for grading levels of product defects. Because there are no ASTM Standard Reference Radiologic data files for addressing this need in the industry, the authors of this paper suggested implementing a method for their creation under ASTM supervision. ASTM can assure continuity to those users making the transition from analog radiographic images to digital image data by swiftly addressing the requirements for reference digital image standards. The current status and possible future activities regarding a method to create digital data files is presented in this paper summary
Prevention and preparedness for response to nuclear and radiological threats
International Nuclear Information System (INIS)
Pradeepkumar, K.S.
2016-01-01
Challenges from smuggled or illegally transported radioactive sources with malevolent intention of causing potential threats to the society are much higher to those potential radiological emergencies from misplaced, orphan or lost radioactive sources. Large number of radioactive sources world over is transported for its application in various fields. The emergency preparedness and response system is less developed for potential radiological emergencies caused by them compared to those at nuclear facilities which are kept in readiness to respond to any kind of emergency. After the terrorist attack on WTC of 2001, there is significant concern world over about the malicious use of nuclear and other radioactive material. This calls for prevention of stealing/smuggling of radioactive materials and improving the emergency response system. Use of Radiological Dispersal Device (RDD) and Improvised Nuclear Device (IND) are considered as possible radiological and nuclear threats, can lead to large area contamination in addition to the injuries caused by blast and thermal effects. (author)
Radiological health training resources, 1979
International Nuclear Information System (INIS)
Munzer, J.E.; Sauer, K.G.
1979-08-01
The training collection maintained by the Division of Training and Medical Applications includes videocassettes, movies, and printed material. Titles are limited to radiological health subjects only and include a variety of topics ranging from basic fundamentals to historical perspectives to current state-of-the-art
Physics Instruction for Radiologic Technologists
Chaney, Edward L.; And Others
1974-01-01
Discusses the Denver collaborative training program in radiologic technology with emphasis upon identification of core topics, preparation of quality instructional materials, and use of innovative teaching techniques, such as computer-assisted instruction and video tape presentations. Included is a 10-week course outline. (CC)
Integrative teaching in Radiology. A survey
International Nuclear Information System (INIS)
Dettmer, S.; Weidemann, J.; Wacker, F.; Fischer, V.
2015-01-01
To survey integrative teaching in radiology at German universities. A questionnaire about radiological education was sent electronically to all 37 chairpersons of university radiology departments in Germany. The questions included the course type, teaching methods, concept, perception, and advantages and disadvantages of integrative teaching. Statistical analysis was performed with nonparametric statistics and chi-square test. The survey was considered representative with a return rate of 68%. Integrative teaching is established at 4/5 of all departments. Integrative teaching is well accepted with an acceptance rate that is significantly higher in so-called 'Modellstudiengaengen' (model courses of study) (100%) compared to conventional courses of study (72%). The advantages of integrative teaching include linking of content (92%) and preparation for interdisciplinary work (76%). The disadvantages include high effort (75%) and time (67%) for organization. Furthermore, there is a risk that basic radiological facts and knowledge cannot be conveyed and that the visibility of radiology as an independent discipline is lost. Conventional radiological teaching has a similarly high acceptance (84%) compared to integrative courses (76%). Integrative teaching has a high acceptance among chairpersons in radiology in Germany despite the greater effort. A good interdisciplinary collaboration is essential for integrative teaching and at the same time this can be conveyed to the students. However, the visibility of radiology as a discipline and the possibility to cover basic radiological content must be ensured. Therefore, both conventional courses and integrative teaching seems reasonable, especially in cross-disciplinary subjects such as radiology.
Emergency radiology curriculum at Medical University - Plovdiv
International Nuclear Information System (INIS)
Velkova, K.; Hilendarov, A.; Cvetkova, S.; Stoeva, M.; Petrova, A.; Stefanov, P.; Simova, E.; Georgieva, V.; Sirakov, N.
2012-01-01
Full text: Introduction: Recent advances in contemporary radiology turn it into one of the major sources for patient information with improved emergency techniques. Emergency Radiology (EP) focuses on acute diagnosing conditions in ER patients. Objectives: The main objective of this paper is to present the ER curriculum at Medical Imaging Department, Medical University - Plovdiv, aiming to deliver knowledge about the indications, possibilities and diagnostic value of the contemporary imaging methods in ER cases. Material and methods: The curriculum covers various aspects of ER Radiology - diagnostic imaging methods, contrast enhanced examinations, imaging topography, traumatic and acute conditions, physical and technical aspects. It includes 6 lectures and 12 practical classes. Results and discussion: The educational course in Emergency Radiology is available for medical students in their 8-th and 9-th semester. Therapeutic methods under imaging control are also covered by the course. Conclusion: Being one of the most advanced areas of radiology, ER improves the quality of care and treatment of patients and of the emergency medicine as a whole
International Nuclear Information System (INIS)
Rathbun, L.A.; Boothe, G.F.
1992-10-01
On May 17, 1991 the US DOE Office of Waste Operations issued a moratorium on the shipment of hazardous waste from radiologically contaminated or potentially contaminated areas on DOE sites to offsite facilities not licensed for radiological material. This document describes a release protocol generated by Westinghouse Hanford submitted for US DOE approval. Topics considered include designating Radiological Materials Management Areas (RMMAs), classification of wastes, handling of mixed wastes, detection limits
2017-11-01
6201 Fort Belvoir, VA 22060-6201 T E C H N IC A L R E P O R T DTRA-TR-15-82 Radiological and Nuclear Detection Material Science : Novel...P.A. Dowben, “Surface Charging at the (100) Surface of Cu doped and undoped Li2B4O7”, Applied Surface Science 257 (2011) 3399-3403 27. S.R...V.T. Adamiv, Ya.V. Burak, P.A. Dowben, “The local structure of Mn doped Li2B4O7(001)”, in preparation for Materials Science and Engineering B 40. C
The Radiological Research Accelerator Facility
International Nuclear Information System (INIS)
Hall, E.J.; Marino, S.A.
1993-05-01
The Radiological Research Accelerator Facility (RARAF) is based on a 4-MV Van de Graaff accelerator, which is used to generate a variety of well-characterized radiation beams for research in radiobiology, radiological physics, and radiation chemistry. It is part of the Center for Radiological Research (CRR) - formerly the Radiological Research Laboratory of Columbia University, and its operation is supported as a National Facility by the US Department of Energy (DOE). As such, RARAF is available to all potential users on an equal basis and scientists outside the CRR are encouraged to submit proposals for experiments at RARAF. The operation of the Van de Graaff is supported by the DOE, but the research projects themselves must be supported separately. This report provides a listing and brief description of experiments performed at RARAF during the May 1, 1992 through April 30, 1993
Implementation of a Radiological Safety Coach program
Energy Technology Data Exchange (ETDEWEB)
Konzen, K.K. [Safe Sites of Colorado, Golden, CO (United States). Rocky Flats Environmental Technology Site; Langsted, J.M. [M.H. Chew and Associates, Golden, CO (United States)
1998-02-01
The Safe Sites of Colorado Radiological Safety program has implemented a Safety Coach position, responsible for mentoring workers and line management by providing effective on-the-job radiological skills training and explanation of the rational for radiological safety requirements. This position is significantly different from a traditional classroom instructor or a facility health physicist, and provides workers with a level of radiological safety guidance not routinely provided by typical training programs. Implementation of this position presents a challenge in providing effective instruction, requiring rapport with the radiological worker not typically developed in the routine radiological training environment. The value of this unique training is discussed in perspective with cost-savings through better radiological control. Measures of success were developed to quantify program performance and providing a realistic picture of the benefits of providing one-on-one or small group training. This paper provides a description of the unique features of the program, measures of success for the program, a formula for implementing this program at other facilities, and a strong argument for the success (or failure) of the program in a time of increased radiological safety emphasis and reduced radiological safety budgets.
Implementation of a Radiological Safety Coach program
International Nuclear Information System (INIS)
Konzen, K.K.
1998-01-01
The Safe Sites of Colorado Radiological Safety program has implemented a Safety Coach position, responsible for mentoring workers and line management by providing effective on-the-job radiological skills training and explanation of the rational for radiological safety requirements. This position is significantly different from a traditional classroom instructor or a facility health physicist, and provides workers with a level of radiological safety guidance not routinely provided by typical training programs. Implementation of this position presents a challenge in providing effective instruction, requiring rapport with the radiological worker not typically developed in the routine radiological training environment. The value of this unique training is discussed in perspective with cost-savings through better radiological control. Measures of success were developed to quantify program performance and providing a realistic picture of the benefits of providing one-on-one or small group training. This paper provides a description of the unique features of the program, measures of success for the program, a formula for implementing this program at other facilities, and a strong argument for the success (or failure) of the program in a time of increased radiological safety emphasis and reduced radiological safety budgets
Probabilistic Radiological Performance Assessment Modeling and Uncertainty
Tauxe, J.
2004-12-01
A generic probabilistic radiological Performance Assessment (PA) model is presented. The model, built using the GoldSim systems simulation software platform, concerns contaminant transport and dose estimation in support of decision making with uncertainty. Both the U.S. Nuclear Regulatory Commission (NRC) and the U.S. Department of Energy (DOE) require assessments of potential future risk to human receptors of disposal of LLW. Commercially operated LLW disposal facilities are licensed by the NRC (or agreement states), and the DOE operates such facilities for disposal of DOE-generated LLW. The type of PA model presented is probabilistic in nature, and hence reflects the current state of knowledge about the site by using probability distributions to capture what is expected (central tendency or average) and the uncertainty (e.g., standard deviation) associated with input parameters, and propagating through the model to arrive at output distributions that reflect expected performance and the overall uncertainty in the system. Estimates of contaminant release rates, concentrations in environmental media, and resulting doses to human receptors well into the future are made by running the model in Monte Carlo fashion, with each realization representing a possible combination of input parameter values. Statistical summaries of the results can be compared to regulatory performance objectives, and decision makers are better informed of the inherently uncertain aspects of the model which supports their decision-making. While this information may make some regulators uncomfortable, they must realize that uncertainties which were hidden in a deterministic analysis are revealed in a probabilistic analysis, and the chance of making a correct decision is now known rather than hoped for. The model includes many typical features and processes that would be part of a PA, but is entirely fictitious. This does not represent any particular site and is meant to be a generic example. A
Relevant radiological anatomy of the pig as a training model in interventional radiology
International Nuclear Information System (INIS)
Dondelinger, R.F.; Ghysels, M.P.; Brisbois, D.; Donkers, E.; Snaps, F.R.; Saunders, J.; Deviere, J.
1998-01-01
The use of swine for teaching purposes in medicine and surgery has largely increased in recent years. Detailed knowledge of the porcine anatomy and physiology is a prerequisite for proper use of pigs as a teaching or an experimental model in interventional radiology. A systematic study of the radiological anatomy was undertaken in more than 100 female pigs aged 6-8 weeks. All studies were performed under general anesthesia in a single session. Animals were sacrificed at the end of the study. Selective angiographies were systematically obtained in all anatomical territories. In other animals CT and MRI examinations were performed and were correlated to anatomical sections and acrylic casts of the vascular structures. Endoscopical examinations of the upper gastrointestinal tract, including retrograde opacification of the biliary and pancreatic ducts, were added in selected animals. The main angiographic aspects of the brain, head and neck, thorax, abdomen, and pelvis were recorded. Similarities and differences in comparison with human anatomy are stressed. Potential applications in interventional radiology are indicated. (orig.)
Auditor recommendations resulting from three clinical audit rounds in Finnish radiology units.
Miettunen, Kirsi; Metsälä, Eija
2017-06-01
Background The purpose of clinical audits performed in radiology units is to reduce the radiation dose of patients and staff and to implement evidence-based best practices. Purpose To describe auditor recommendations in three Finnish clinical audit rounds performed in 2002-2014, and to determine if auditor recommendations have had any impact on improving medical imaging practice. Material and Methods The retrospective observational study was performed in radiology units holding a radiation safety license issued by the Finnish Radiation and Nuclear Safety Authority. The data comprised a systematic sample (n = 120) of auditor reports produced in three auditing rounds in these units during the years 2002-2014. The data were analyzed by descriptive methods and by using the Friedman two-way ANOVA test. Results The number of auditor recommendations given varied between clinical audit rounds and according to the type of imaging unit, as well as according to calculation method. Proportionally, the most recommendations in all three clinical audit rounds were given about defining and using quality assurance functions and about guidelines and practices for carrying out procedures involving radiation exposure. Demanding radiology units improved their practices more than basic imaging units towards the third round. Conclusion Auditor recommendations help to address the deficiencies in imaging practices. There is a need to develop uniform guidelines and to provide tutoring for clinical auditors in order to produce comparable clinical audit results.
Radioactive material packaging performance testing
International Nuclear Information System (INIS)
Romano, T.
1992-06-01
In an effort to provide uniform packaging of hazardous material on an international level, recommendations for the transport of dangerous goods have been developed by the United Nations. These recommendations are performance oriented and contrast with a large number of packaging specifications in the US Department of Transportation's hazard materials regulations. This dual system presents problems when international shipments enter the US Department of Transportation's system. Faced with the question of continuing a dual system or aligning with the international system, the Research and Special Programs Administration of the US Department of Transportation responded with Docket HM-181. This began the transition toward the international transportation system. Following close behind is Docket HM-169A, which addressed low specific activity radioactive material packaging. This paper will discuss the differences between performance-oriented and specification packaging, the transition toward performance-oriented packaging by the US Department of Transportation, and performance-oriented testing of radioactive material packaging by Westinghouse Hanford Company. Dockets HM-181 and HM-169A will be discussed along with Type A (low activity) and Type B (high activity) radioactive material packaging evaluations
Shiraishi, Junji; Pesce, Lorenzo L.; Metz, Charles E.; Doi, Kunio
2009-01-01
Purpose: To provide a broad perspective concerning the recent use of receiver operating characteristic (ROC) analysis in medical imaging by reviewing ROC studies published in Radiology between 1997 and 2006 for experimental design, imaging modality, medical condition, and ROC paradigm. Materials and Methods: Two hundred ninety-five studies were obtained by conducting a literature search with PubMed with two criteria: publication in Radiology between 1997 and 2006 and occurrence of the phrase “receiver operating characteristic.” Studies returned by the query that were not diagnostic imaging procedure performance evaluations were excluded. Characteristics of the remaining studies were tabulated. Results: Two hundred thirty-three (79.0%) of the 295 studies reported findings based on observers' diagnostic judgments or objective measurements. Forty-three (14.6%) did not include human observers, with most of these reporting an evaluation of a computer-aided diagnosis system or functional data obtained with computed tomography (CT) or magnetic resonance (MR) imaging. The remaining 19 (6.4%) studies were classified as reviews or meta-analyses and were excluded from our subsequent analysis. Among the various imaging modalities, MR imaging (46.0%) and CT (25.7%) were investigated most frequently. Approximately 60% (144 of 233) of ROC studies with human observers published in Radiology included three or fewer observers. Conclusion: ROC analysis is widely used in radiologic research, confirming its fundamental role in assessing diagnostic performance. However, the ROC studies reported in Radiology were not always adequate to support clear and clinically relevant conclusions. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533081632/-/DC1 PMID:19864510
Guidelines for radiological performance assessment of DOE low-level radioactive waste disposal sites
International Nuclear Information System (INIS)
Case, M.J.; Otis, M.D.
1988-07-01
This document provides guidance for conducting radiological performance assessments of Department of Energy (DOE) low-level radioactive waste (LLW) disposal facilities. The guidance is specifically intended to provide the fundamental approach necessary to meet the performance assessment requirements. The document is written for LLW facility operators or other personnel who will manage the performance assessment task. The document is meant to provide guidance for conducting performance assessments in a generally consistent manner at all DOE LLW disposal facilities. The guidance includes a summary of performance objectives to be met by LLW disposal facilities (these objectives are derived from current DOE and other applicable federal regulatory guidelines); specific criteria for an adequate performance assessment and from which a minimum set of required calculations may be determined; recommendations of methods for screening critical components of the analysis system so that these components can be addressed in detail; recommendations for the selection of existing models and the development of site-specific models; recommendations of techniques for comparison of assessment results with performance objectives; and a summary of reporting requirements
International Nuclear Information System (INIS)
1997-06-01
A radiological dose assessment has been performed for Clean Slate Sites 1, 2, and 3 at the Tonopah Test Range, approximately 390 kilometers (240 miles) northwest of Las Vegas, Nevada. The assessment demonstrated that the calculated dose to hypothetical individuals who may reside or work on the Clean Slate sites, subsequent to remediation, does not exceed the limits established by the US Department of Energy for protection of members of the public and the environment. The sites became contaminated as a result of Project Roller Coaster experiments conducted in 1963 in support of the US Atomic Energy Commission (Shreve, 1964). Remediation of Clean Slate Sites 1, 2, and 3 is being performed to ensure that the 50-year committed effective dose equivalent to a hypothetical individual who lives or works on a Clean Slate site should not exceed 100 millirems per year. The DOE residual radioactive material guideline (RESRAD) computer code was used to assess the dose. RESRAD implements the methodology described in the DOE manual for establishing residual radioactive material guidelines (Yu et al., 1993a). In May and June of 1963, experiments were conducted at Clean Slate Sites 1, 2, and 3 to study the effectiveness of earth-covered structures for reducing the dispersion of nuclear weapons material as a result of nonnuclear explosions. The experiments required the detonation of various simulated weapons using conventional chemical explosives (Shreve, 1964). The residual radioactive contamination in the surface soil consists of weapons grade plutonium, depleted uranium, and their radioactive decay products
Energy Technology Data Exchange (ETDEWEB)
NONE
1997-06-01
A radiological dose assessment has been performed for Clean Slate Sites 1, 2, and 3 at the Tonopah Test Range, approximately 390 kilometers (240 miles) northwest of Las Vegas, Nevada. The assessment demonstrated that the calculated dose to hypothetical individuals who may reside or work on the Clean Slate sites, subsequent to remediation, does not exceed the limits established by the US Department of Energy for protection of members of the public and the environment. The sites became contaminated as a result of Project Roller Coaster experiments conducted in 1963 in support of the US Atomic Energy Commission (Shreve, 1964). Remediation of Clean Slate Sites 1, 2, and 3 is being performed to ensure that the 50-year committed effective dose equivalent to a hypothetical individual who lives or works on a Clean Slate site should not exceed 100 millirems per year. The DOE residual radioactive material guideline (RESRAD) computer code was used to assess the dose. RESRAD implements the methodology described in the DOE manual for establishing residual radioactive material guidelines (Yu et al., 1993a). In May and June of 1963, experiments were conducted at Clean Slate Sites 1, 2, and 3 to study the effectiveness of earth-covered structures for reducing the dispersion of nuclear weapons material as a result of nonnuclear explosions. The experiments required the detonation of various simulated weapons using conventional chemical explosives (Shreve, 1964). The residual radioactive contamination in the surface soil consists of weapons grade plutonium, depleted uranium, and their radioactive decay products.
Radiological characterization for small type light water reactor
International Nuclear Information System (INIS)
Tanaka, Ken-ichi; Ichige, Hideaki; Tanabe, Hidenori
2011-01-01
In order to plan a decommissioning, amount investigation of waste materials and residual radioactivity inventory evaluation must be performed at the first stage of preparatory tasks. These tasks are called radiological characterization. Reliable information from radiological characterization is crucial for specification of decommissioning plan. With the information, we can perform radiological safety analysis and optimize decommissioning scenario. Japan Atomic Power Company (JAPC) has already started preparatory tasks for Tsuruga Nuclear Power Plant Unit 1 (TS-1) that is the first commercial Small Type Light Water Reactor in Japan. To obtain reliable information about residual radioactivity inventory, we improved radioactivity inventory evaluation procedure. The procedure consists of neutron flux distribution calculation and radioactivity distribution calculation. We need a better understanding about characteristics of neutron transport phenomena in order to obtain reliable neutron flux distribution. Neutron flux was measured in Primary Containment Vessel (PCV) at 30 locations using activation foils. We chose locations where characteristic phenomena can be observed. Three dimensional (3D) neutron flux calculation was also performed to simulate continuous changes of neutron flux distribution. By assessing both the measured values and 3D calculation results, we could perform the calculation that simulates the phenomena well. We got knowledge about how to perform an appropriate neutron flux distribution calculation and also became able to calculate a reliable neutron flux distribution. Using the neutron flux distribution, we can estimate a reliable radioactivity distribution. We applied network-parallel-computing method to the estimation. And further we developed 'flux level approximation method' which use linear or parabola fitting method to estimation. Using these new methods, radioactivity by neutron irradiation, which is radioisotope formation, was calculated at
Radiology in managed care environment: Opportunities for cost savings in an HMO
International Nuclear Information System (INIS)
Schmidt, C.; Heller, M.
2003-01-01
Purpose: A large regional health plan in the Northeastern United States noted that its radiology costs were increasing more than it anticipated in its pricing, and noted further that other similar health plans in markets with high managed care penetration had significantly lower expenses for radiology services. This study describes the potential areas of improvement and managed care techniques that were implemented to reduce costs and reform processes. Materials and methods: We performed an in-depth analysis of financial data, claims logic, contracting with provider units and conducted interviews with employees, to identify potential areas of improvement and cost reduction. A detailed market analysis of the environment, competitors and vendors was accompanied by extensive literature, Internet and Medline search for comparable projects. All data were documented in Microsoft Excel trademark and analyzed by non-parametric tests using SPSS trademark 8.0 (Statistical Package for the Social Sciences) for Windows trademark . Results: The main factors driving the cost increases in radiology were divided into those internal or external to the HMO. Among the internal factors, the claims logic was allowing overpayment due to limitations of the IT system. Risk arrangements between insurer and provider units (PU) as well as the extent of provider unit management and administration showed a significant correlation with financial performance in terms of variance from budget. Among the external factors, shared risk arrangements between HMO and provider unit were associated with more efficient radiology utilization and overall improvement in financial performance. PU with full-time management had significantly less variance from their budget than those without. Finally, physicians with imaging equipment in their offices ordered up to 4 to 5 times more imaging procedures than physicians who did not perform imaging studies themselves. (orig.) [de
Radiological Worker Training: Radiological Worker 2 study guides
International Nuclear Information System (INIS)
1992-10-01
Upon completion of this training course, the participant will have the knowledge to work safely in areas controlled for radiological purposes using proper radiological practices. Radiological Worker H Training, for the worker whose job assignment involves entry into Radiological Buffer Areas and all types of Radiation Contamination and Airborne Radioactivity Areas. This course is designed to prepare the worker to work safely in and around radiological areas and present methods to use to ensure individual radiation exposure is maintained As Low As Reasonably Achievable
Radiological Work Planning and Procedures
International Nuclear Information System (INIS)
KURTZ, J.E.
2000-01-01
Each facility is tasked with maintaining personnel radiation exposure as low as reasonably achievable (ALARA). A continued effort is required to meet this goal by developing and implementing improvements to technical work documents (TWDs) and work performance. A review of selected TWDs from most facilities shows there is a need to incorporate more radiological control requirements into the TWD. The Radioactive Work Permit (RWP) provides a mechanism to place some of the requirements but does not provide all the information needed by the worker as he/she is accomplishing the steps of the TWD. Requiring the engineers, planners and procedure writers to put the radiological control requirements in the work steps would be very easy if all personnel had a strong background in radiological work planning and radiological controls. Unfortunately, many of these personnel do not have the background necessary to include these requirements without assistance by the Radiological Control organization at each facility. In addition, there seems to be confusion as to what should be and what should not be included in the TWD
ICRP PUBLICATION 121: Radiological Protection in Paediatric Diagnostic and Interventional Radiology
International Nuclear Information System (INIS)
Khong, P-L.; Ringertz, H.; Donoghue, V.; Frush, D.; Rehani, M.; Appelgate, K.; Sanchez, R.
2013-01-01
Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities – radiography and fluoroscopy, interventional radiology, and computed tomography – are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation
International Nuclear Information System (INIS)
Margulis, A.R.; Gooding, C.A.
1987-01-01
This is the latest version of the continuing education course on diagnostic radiology given yearly by the Department of Radiology at the University of California, San Francisco. The lectures are grouped into sections on gastrointestinal radiology, mammography, uroradiology, magnetic resonance, hepatobiliary radiology, pediatric radiology, ultrasound, interventional radiology, chest radiology, nuclear medicine, cardiovascular radiology, and skeletal radiology. Each section contains four to eight topics. Each of these consists of text that represents highlights in narrative form, selected illustrations, and a short bibliography. The presentation gives a general idea of what points were made in the lecture
Radiological safety and risk assessment
International Nuclear Information System (INIS)
Hunter, P.H.; Barg, D.C.; Baird, R.D.; Card, D.H.; de Souza, F.; Elder, J.; Felthauser, K.; Jensen, C.; Winkler, V.
1982-02-01
A brief radiological safety and risk assessment of a nuclear power generation center with an adjacent on-site waste disposal facility at a specific site in the State of Utah is presented. The assessment was conducted to assist in determining the feasibility and practicality of developing a nuclear energy center (NEC) in Utah consisting of nine 1250 MWe nuclear pressurized water reactor (PWR) electrical generating units arranged in 3 clusters of 3 units each known as triads. The site selected for this conceptual study is in the Horse Bench area about 15 miles directly south of the town of Green River, Utah. The radiological issues included direct radiation exposures to on-site workers and the off-site population, release of radioactive material, and effects of these releases for both normal operations and accidental occurrences. The basic finding of this study is that the concept of an NEC in the Green River area, specifically at the Horse Bench site, is radiologically feasible
Energy Technology Data Exchange (ETDEWEB)
Hickey, Eva E.; Strom, Daniel J.
2005-08-01
Staff of the King County Wastewater Treatment Division (WTD) have concern about the aftermath of a radiological dispersion event (RDE) leading to the introduction of significant quantities of radioactive material into the combined sanitary and storm sewer system in King County, Washington. Radioactive material could come from the use of a radiological dispersion device (RDD). RDDs include "dirty bombs" that are not nuclear detonations but are explosives designed to spread radioactive material (National Council on Radiation Protection and Measurements (NCRP) 2001). Radioactive material also could come from deliberate introduction or dispersion of radioactive material into the environment, including waterways and water supply systems. This document, Volume 3 of PNNL-15163 is the technical basis for the Annex to the West Point Treatment Plant (WPTP) Emergency Response Plan related to responding to a radiological emergency at the WPTP. The plan primarily considers response to radioactive material that has been introduced in the other combined sanitary and storm sewer system from a radiological dispersion device, but is applicable to any accidental or deliberate introduction of materials into the system.
Environmental aspects at radiological protection in ArcelorMittal Monlevade
International Nuclear Information System (INIS)
Silva Filho, Cleber Marques; Soares Filho, Mauricio; Franco, Jose Otavio Andrade; Leite, Roberto Paulo; Goncalves, Breno Cunha; Costa, Jose Gustavo de Souza
2010-01-01
ArcelorMittal Monlevade Environmental Management of Radiological Protection is based on radiological protection team training, start up of radioactivity materials detection equipment in several steps of industrial processes and internal procedures according to CNEN - Nuclear Energy National Commission guidelines. At this way ArcelorMittal Monlevade seeks to guarantee the safety of employees, community, customers, equipment and the environment and their business. (author)
Energy Technology Data Exchange (ETDEWEB)
Woisetschlaeger, Mischa, E-mail: Mischa.woisetschlager@lio.se [Center for Medical Image Science and Visualisation (CMIV), University Hospital Linkoeping, Linkoeping University, 58185 Linkoeping (Sweden); Lussi, Adrian, E-mail: anders.persson@cmiv.lio.se [Department of Preventive, Restorative and Pediatric Dentistry, School of Dental Medicine, University of Bern, Freiburgstrasse 7, 3010 Bern (Switzerland); Persson, Anders, E-mail: adrian.lussi@zmk.unibe.ch [Center for Medical Image Science and Visualisation (CMIV), University Hospital Linkoeping, Linkoeping University, 58185 Linkoeping (Sweden); Jackowski, Christian, E-mail: christian.jackowski@irm.uzh.ch [Center for Medical Image Science and Visualisation (CMIV), University Hospital Linkoeping, Linkoeping University, 58185 Linkoeping (Sweden); Institute of Legal Medicine, University of Zuerich, Winterthurerstrasse 190/52, 8057 Zuerich (Switzerland)
2011-11-15
Objectives: The aim of this study was to evaluate the use of high resolution CT to radiologically define teeth filling material properties in terms of Hounsfield units after high temperature exposure. Methods: 122 human molars with 10 different filling materials at defined filling diameters were examined. The teeth were CT scanned both before and after the exposure to different temperatures. After image reconstruction, the teeth and filling materials were analyzed regarding their morphology and Hounsfield units (HU) using an extended HU scale. Results: The majority of filling materials diminished in size at temperatures {>=}400 deg. C. HU values were stable for all materials up till 200 deg. C, and only slightly changed up to 600 deg. C. Cerec, Dyract and dentin showed only minor changes in HU at all temperatures. The other materials, inclusive enamel, showed specific patterns, either increasing or decreasing in HU with increasing temperatures over 600 deg. C. Conclusions: Over 600 deg. C the filling materials show specific patterns that can be used to discriminate filling materials. Ultra high resolution CT may improve the identification processes in fire victims. Existing 3D visualization presets for the dentition can be used until 600 deg. C and have to be optimized for bodies exposed to higher temperatures.
International Nuclear Information System (INIS)
Woisetschlaeger, Mischa; Lussi, Adrian; Persson, Anders; Jackowski, Christian
2011-01-01
Objectives: The aim of this study was to evaluate the use of high resolution CT to radiologically define teeth filling material properties in terms of Hounsfield units after high temperature exposure. Methods: 122 human molars with 10 different filling materials at defined filling diameters were examined. The teeth were CT scanned both before and after the exposure to different temperatures. After image reconstruction, the teeth and filling materials were analyzed regarding their morphology and Hounsfield units (HU) using an extended HU scale. Results: The majority of filling materials diminished in size at temperatures ≥400 deg. C. HU values were stable for all materials up till 200 deg. C, and only slightly changed up to 600 deg. C. Cerec, Dyract and dentin showed only minor changes in HU at all temperatures. The other materials, inclusive enamel, showed specific patterns, either increasing or decreasing in HU with increasing temperatures over 600 deg. C. Conclusions: Over 600 deg. C the filling materials show specific patterns that can be used to discriminate filling materials. Ultra high resolution CT may improve the identification processes in fire victims. Existing 3D visualization presets for the dentition can be used until 600 deg. C and have to be optimized for bodies exposed to higher temperatures.
The Pathology of Infection in the Department of Radiology
Energy Technology Data Exchange (ETDEWEB)
Shin, Seong Gyu [Dept. of Radiology, Dong a University Medical Center, Pusan (Korea, Republic of); Lee, Hyo Yeong [Dept. of Nuclear Medicine, Pusan National University Hospital, Pusan (Korea, Republic of)
2012-09-15
This study was performed to understand the bacteriologic contamination level of radiological equipment which have frequent contacts with patients in the Department of Radiology of an university hospital in Busan area. Before sterilizing in-patient of the radiology rooms, MRSA, VRE, acinetobacter baumannii, candida albicans, and enterococcus sp. were detected. After sterilization, all the bacteria were not found. As examine times become longer, more bacteria were detected and after 7 hours, bacillus sp.(GPR), CNS, acinetobacter baumannii, and Enterococcus sp. were detected. After examining infected patients, bacillus sp.(GPR), VRE, enterococcus sp. CNS, and micrococcus sp. were detected and on the hands of radiological technologists, CNS, enterococcus sp. escherichia coli, and enterobacter sp. were detected. Similar species of bacteria were detected from each radiology room, but pseudomonas aeruginosa was detected on the handles of portable radiological equipment and the chair in the waiting room. Therefore, it is the most important to regularly sterilize radiological equipment and devices which have frequent contacts with patients and to sterilize them right after the use of infected patients in order to prevent the spread of infection. Also, thorough hand washing, education on infection and management for the characteristics of Department of Radiology should be performed for the systematic prevention of infection.
The Pathology of Infection in the Department of Radiology
International Nuclear Information System (INIS)
Shin, Seong Gyu; Lee, Hyo Yeong
2012-01-01
This study was performed to understand the bacteriologic contamination level of radiological equipment which have frequent contacts with patients in the Department of Radiology of an university hospital in Busan area. Before sterilizing in-patient of the radiology rooms, MRSA, VRE, acinetobacter baumannii, candida albicans, and enterococcus sp. were detected. After sterilization, all the bacteria were not found. As examine times become longer, more bacteria were detected and after 7 hours, bacillus sp.(GPR), CNS, acinetobacter baumannii, and Enterococcus sp. were detected. After examining infected patients, bacillus sp.(GPR), VRE, enterococcus sp. CNS, and micrococcus sp. were detected and on the hands of radiological technologists, CNS, enterococcus sp. escherichia coli, and enterobacter sp. were detected. Similar species of bacteria were detected from each radiology room, but pseudomonas aeruginosa was detected on the handles of portable radiological equipment and the chair in the waiting room. Therefore, it is the most important to regularly sterilize radiological equipment and devices which have frequent contacts with patients and to sterilize them right after the use of infected patients in order to prevent the spread of infection. Also, thorough hand washing, education on infection and management for the characteristics of Department of Radiology should be performed for the systematic prevention of infection.
Radiological Assistance Program, DOE Region 6 response plan
International Nuclear Information System (INIS)
Jakubowski, F.M.
1993-02-01
This program plan meets all the requirements identified in DOE Order 5530.3, Radiological Assistance Program and supports those requirements leading to the establishment of a Federal Radiological Monitoring and Assessment Center (FRMAC) as required by DOE 5530-5. Requests for radiological assistance may come from other DOE facilities, Federal or state agencies, tribal officials, or from any private corporation or individual. Many of the requests will be handled by a telephone call, a conference or a letter, teletype or memorandum. Other requests for assistance may involve radioactive material in serious accidents, fire, personal injuries, contamination or possible hazards to the general public. Some occurrences may require the dispatch of trained personnel equipped with radiation monitoring instruments and related equipment necessary to evaluate, control and neutralize the hazard. The primary responsibility for incidents involving radioactive material always remains with the party having custody of the radioactive materials. In addition, the DOE recognizes that the assistance provided shall not in any way preempt state, tribal, or local authority and/or responsibility on state or tribal properties. Toward this end, DOE assistance for non-DOE radioactive materials, is limited to technical assistance, advice, measurement and other resources as deemed necessary by the local authorities but excludes DOE interface with the public media. This is a function handled by the local or state Incident Commander
International Nuclear Information System (INIS)
Smith, K.P.; Blunt, D.L.; Williams, G.P.
1996-09-01
A preliminary radiological dose assessment of equipment decontamination, subsurface disposal, landspreading, equipment smelting, and equipment burial was conducted to address concerns regarding the presence of naturally occurring radioactive materials (NORM) in production waste streams. The assessment estimated maximum individual dose equivalents for workers and the general public. Sensitivity analyses of certain input parameters also were conducted. On the basis of this assessment, it is concluded that (1) regulations requiring workers to wear respiratory protection during equipment cleaning operations are likely to result in lower worker doses, (2) underground injection and downhole encapsulation of NORM wastes present a negligible risk to the general public, and (3) potential doses to workers and the general public related to smelting NORM-contaminated equipment can be controlled by limiting the contamination level of the initial feed. It is recommended that (1) NORM wastes be further characterized to improve studies of potential radiological doses; (2) states be encouraged to permit subsurface disposal of NORM more readily, provided further assessments support this study; results; (3) further assessment of landspreading NORM wastes be conducted; and (4) the political, economic, sociological, and nonradiological issues related to smelting NORM-contaminated equipment be studied to fully examine the feasibility of this disposal option
RadSTraM: Radiological Source Tracking and Monitoring, Phase II Final Report
Energy Technology Data Exchange (ETDEWEB)
Warren, Tracy A [ORNL; Walker, Randy M [ORNL; Hill, David E [ORNL; Gross, Ian G [ORNL; Smith, Cyrus M [ORNL; Abercrombie, Robert K [ORNL
2008-12-01
This report focuses on the technical information gained from the Radiological Source Tracking and Monitoring (RadSTraM) Phase II investigation and its implications. The intent of the RadSTraM project was to determine the feasibility of tracking radioactive materials in commerce, particularly International Atomic Energy Agency (IAEA) Category 3 and 4 materials. Specifically, Phase II of the project addressed tracking radiological medical isotopes in commerce. These categories of materials are susceptible to loss or theft but the problem is not being addressed by other agencies.
RadSTraM: Radiological Source Tracking and Monitoring, Phase II Final Report
International Nuclear Information System (INIS)
Warren, Tracy A.; Walker, Randy M.; Hill, David E.; Gross, Ian G.; Smith, Cyrus M.; Abercrombie, Robert K.
2008-01-01
This report focuses on the technical information gained from the Radiological Source Tracking and Monitoring (RadSTraM) Phase II investigation and its implications. The intent of the RadSTraM project was to determine the feasibility of tracking radioactive materials in commerce, particularly International Atomic Energy Agency (IAEA) Category 3 and 4 materials. Specifically, Phase II of the project addressed tracking radiological medical isotopes in commerce. These categories of materials are susceptible to loss or theft but the problem is not being addressed by other agencies
International Nuclear Information System (INIS)
Mladineo, Stephen V.
2007-01-01
Introductory article for special edition of the JOURNAL OF NUCLEAR MATERIALS MANAGEMENT outlining the Institute of Nuclear Materials Management Nonproliferation and Arms Control Technical Division. In particular the International Nuclear and Radiological Security Standing Committee and its initial focus covering four topical areas--Radiological Threat Reduction, Nuclear Smuggling and Illicit Trafficking, Countering Nuclear Terrorism, and Radiological Terrorism Consequence Management
Implementation of a remote system for monitoring of radiological areas of radiological areas
International Nuclear Information System (INIS)
Velazquez E, Walter; Galuppo G, Emiliano; Gutierrez G, Jorge; Reyes R, Jerson
2008-01-01
Full text: Introduction: The present work shows the development of a radiation remote monitoring system which control radiological areas in the principal facilities at CCHEN and the development in the last years to use this system called SMARR (Remote Radiological Area Monitoring System). This is an important issue in radiological safety is to know 'on line' and in a 'continuously way' the radiological variables of areas, especially if in these areas people manage radioactive sources or material, the monitoring system are operative on La Reina and Lo Aguirre Nuclear Centers. This 'knowledge' gets a good support to the radiological safety to safeguard the environment and people in the facilities. Nuclear Chilean Commission: Actually, this system is daily operating to register the background radiation and level operation, for example of the facilities research reactor, cyclone, irradiators, in order to probe the behaviors under operational requirements. The system was made using common Geiger Muller and NaI detectors. This signal is received, data by data, for a collector computer which uses a Labview program to do this displayed on a screen computer using graphics to show the activity on a radiological area, and when the lectures pass a setting value automatically the system send by e-mail and text message which also can be received for cell phones enabled for this for the supervisor. Each monitored facility is completely independent of each other and store a data backup, also every installation are monitoring with server computer, it's concentrating the information and allow to view it on line in real time, trough the intranet and internet network. In addition, the information is stored in the special report in the server and available for to do a statistics and identify the operation periods, and control of radioactive sources. The Industry: The radiological protection on industry is necessary today, the typical instrumentation on the industry is growing up in the
Lu, Xinwei; Li, Nan; Yang, Guang; Zhao, Caifeng
2013-03-01
The concentration of natural radionuclides in commonly used building materials collected from Yan'an, China, was determined using gamma ray spectroscopy with a NaI(Tl) detector. The activity concentration of ²²⁶Ra, ²³²Th, and ⁴⁰K in the studied building materials ranges from 9.4-73.1, 11.5-86.9, and 258.9-1,055.1 Bq kg⁻¹, respectively. The concentrations for these natural radionuclides were compared with the reported data of other countries and the world mean values for soil. The radium equivalent activity (Raeq), external hazard index (Hex), internal hazard index (Hin), indoor air absorbed dose rate, and annual effective dose rate due to natural radionuclides in samples were estimated to assess radiological hazards for people living in dwellings made of the studied building materials. The calculated Raeq values of all building materials (75.7-222.1 Bq kg⁻¹) are lower than the limit of 370 Bq kg⁻¹. The values of Hex and Hin are less than unity. The mean values of indoor air absorbed dose rates of all building materials (101.0 ± 14.1-177.0 ± 6.8 nGy h⁻¹) are higher than the world population-weighted average of 84 nGy h⁻¹, while the mean values of annual effective dose range from 0.50 ± 0.07-0.87 ± 0.03 mSv y⁻¹, which are lower than the recommended limit of 1 mSv y⁻¹. It is found that these materials may be used safely as construction materials and do not pose significant radiation hazards to inhabitants.
Radiological emergency preparedness (REP) program
International Nuclear Information System (INIS)
Kwiatkowski, D.H.
1995-01-01
This talk focuses on the accomplishments of Radiological Emergency Preparedness Program. Major topics include the following: strengthening the partnership between FEMA, the States, and the Industry; the Standard Exercise Report Format (SERF); Multi-year performance partnership agreement (MYPPA); new REP Program guidance; comprehensive exercise program; federal radiological emergency response plan (FRERP); international interest; REP user fee; implementation EPA PAGs and Dose Limits; Contamination monitoring standard for portal monitors; guidance documents and training
Detecting Illicit Nuclear Materials
International Nuclear Information System (INIS)
Kouzes, Richard T.
2005-01-01
The threat that weapons of mass destruction might enter the United States has led to a number of efforts for the detection and interdiction of nuclear, radiological, chemical, and biological weapons at our borders. There have been multiple deployments of instrumentation to detect radiation signatures to interdict radiological material, including weapons and weapons material worldwide
van der Gijp, A; Ravesloot, C J; Jarodzka, H; van der Schaaf, M F; van der Schaaf, I C; van Schaik, J P J; ten Cate, Olle
Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review
A Performance Weighted Collaborative Filtering algorithm for personalized radiology education.
Lin, Hongli; Yang, Xuedong; Wang, Weisheng; Luo, Jiawei
2014-10-01
Devising an accurate prediction algorithm that can predict the difficulty level of cases for individuals and then selects suitable cases for them is essential to the development of a personalized training system. In this paper, we propose a novel approach, called Performance Weighted Collaborative Filtering (PWCF), to predict the difficulty level of each case for individuals. The main idea of PWCF is to assign an optimal weight to each rating used for predicting the difficulty level of a target case for a trainee, rather than using an equal weight for all ratings as in traditional collaborative filtering methods. The assigned weight is a function of the performance level of the trainee at which the rating was made. The PWCF method and the traditional method are compared using two datasets. The experimental data are then evaluated by means of the MAE metric. Our experimental results show that PWCF outperforms the traditional methods by 8.12% and 17.05%, respectively, over the two datasets, in terms of prediction precision. This suggests that PWCF is a viable method for the development of personalized training systems in radiology education. Copyright © 2014. Published by Elsevier Inc.
Evaluation of use of e-Learning in undergraduate radiology education: A review
Energy Technology Data Exchange (ETDEWEB)
Zafar, Saad, E-mail: saad.zafar@riphah.edu.pk [Riphah International University, Islamabad (Pakistan); Safdar, Saima, E-mail: saima.safdar@riphah.edu.pk [Riphah International University, Islamabad (Pakistan); Zafar, Aasma N., E-mail: aasmarad@gmail.com [Radiology Department, Senior Registrar Shifa College of Medicine and Assistant Consultant Shifa International Hospital, Islamabad (Pakistan)
2014-12-15
Highlights: • We have systematically reviewed the literature on use of e-Learning in Radiology at the undergraduate level. • Kirkpatrick's Learning Model is used to evaluate the learning outcomes of the reported studies. • There is an increase in positive response for learning management systems used in blended learning environments. • There are wide range of technologies being used for e-Learning including use of audio response system and customized PAC solutions. • There is a clear trend toward highly interactive, self directed learning environment to support the concept of life long independent learners. - Abstract: Purpose: The aim of this review is to investigate the evaluative outcomes present in the literature according to Kirkpatrick's learning model and to examine the nature and characteristics of the e-Learning interventions in radiology education at undergraduate level. Materials and methods: Four databases (PubMed, MEDLINE, Embase, Eric) are searched for publications related to the application of e-Learning in undergraduate radiology education. The search strategy is a combination of e-Learning and Mesh and non Mesh radiology and undergraduate related terms. These search strategies are established in relation to experts of respective domains. The full text of thirty pertinent articles is reviewed. Author's country and study location data is extracted to identify the most active regions and year's are extracted to know the existing trend. Data regarding radiology subfields and undergraduate year of radiology education is extracted along with e-Learning technologies to identify the most prevalent or suitable technologies or tools with respect to radiology contents. Kirkpatricks learning evaluation model is used to categorize the evaluative outcomes reported in the identified studies. Results: The results of this analysis reveal emergence of highly interactive games, audience response systems and designing of wide range of
Evaluation of use of e-Learning in undergraduate radiology education: A review
International Nuclear Information System (INIS)
Zafar, Saad; Safdar, Saima; Zafar, Aasma N.
2014-01-01
Highlights: • We have systematically reviewed the literature on use of e-Learning in Radiology at the undergraduate level. • Kirkpatrick's Learning Model is used to evaluate the learning outcomes of the reported studies. • There is an increase in positive response for learning management systems used in blended learning environments. • There are wide range of technologies being used for e-Learning including use of audio response system and customized PAC solutions. • There is a clear trend toward highly interactive, self directed learning environment to support the concept of life long independent learners. - Abstract: Purpose: The aim of this review is to investigate the evaluative outcomes present in the literature according to Kirkpatrick's learning model and to examine the nature and characteristics of the e-Learning interventions in radiology education at undergraduate level. Materials and methods: Four databases (PubMed, MEDLINE, Embase, Eric) are searched for publications related to the application of e-Learning in undergraduate radiology education. The search strategy is a combination of e-Learning and Mesh and non Mesh radiology and undergraduate related terms. These search strategies are established in relation to experts of respective domains. The full text of thirty pertinent articles is reviewed. Author's country and study location data is extracted to identify the most active regions and year's are extracted to know the existing trend. Data regarding radiology subfields and undergraduate year of radiology education is extracted along with e-Learning technologies to identify the most prevalent or suitable technologies or tools with respect to radiology contents. Kirkpatricks learning evaluation model is used to categorize the evaluative outcomes reported in the identified studies. Results: The results of this analysis reveal emergence of highly interactive games, audience response systems and designing of wide range of
Singh, Harjit
2011-01-01
""Radiology Fundamentals"" is a concise introduction to the dynamic field of radiology for medical students, non-radiology house staff, physician assistants, nurse practitioners, radiology assistants, and other allied health professionals. The goal of the book is to provide readers with general examples and brief discussions of basic radiographic principles and to serve as a curriculum guide, supplementing a radiology education and providing a solid foundation for further learning. Introductory chapters provide readers with the fundamental scientific concepts underlying the medical use of imag
Response to nuclear and radiological terrorism - the viewpoint from the security forces
International Nuclear Information System (INIS)
Baciu, A.
2005-01-01
Full text: A threat of a malevolent act may be deemed to exist when information has been received that terrorists, criminals or other persons intend to: manufacture, use, transport, dispose radioactive materials in order to hide the nature of material; perpetrate a deliberate act to irradiate a person or persons; perpetrate a deliberate act to contaminate food or water supplies with radioactive materials; create and deploy a radiation dispersal device; perpetrate a deliberate act to contaminate a site or the environment with radioactive materials; or mount a sabotage attack upon a nuclear facility aimed at causing an uncontrolled release of radioactive materials. Security forces will be involved in all aspects of the response: at the scene, to lead, to control the crime scene and preserve evidence; at the hospitals, to identify and manage witnesses who may assist in the ensuing investigation, and to protect emergency medical personnel if perpetrators are part of the casualties; and at the regional and national coordination level, to manage the overall criminal investigation; to take under physical protection the seized materials. Law enforcement response: key considerations to all police (security and investigating) personnel at the scene of a terrorist act will include the following: do not approach the scene without proper radiological support; be aware of the possible presence of other radiological hazards; the radiological team will seek the removal of safety hazards. Work with that team to minimize hazards while not compromising the investigation. Minimize traffic through the scene: this will help reduce the spread of radioactive contamination, if present; people present at the scene need to be held for questioning. However, they will also have fears due to the presence of radiation. Work with the radiological team to minimize radiological hazards and fears while not compromising the investigation procedure. (author)
Emergency response during the radiological control of scraps in Cuba
International Nuclear Information System (INIS)
Ramos Viltre, Enma O.; Cardenas Herrera, Juan; Dominguez Ley, Orlando; Capote Ferrera, Eduardo; Fernandez Gomez, Isis M.; Caveda Ramos, Celia; Carrazana, Jorge; Barroso Perez, Idelisa
2008-01-01
In the last few years, in the international scene, incidents have been reported due to the presence of radioactive materials in the scrap. This reality has motivated the adoption of measures of radiological security, due to the implications that these incidents have for the public and the environment, as well as for the international trade. Among theses actions is the implementation of the radiological control of scrap, with the additional requirement that this control has to be implemented in the framework of a Quality Management Program.Taking into account the international experience, our institution designed and organized in 2002 a national service for the radiological monitoring of scrap, being the clients the main exporting and trading enterprises of this material in the country. During these years, several contaminated materials have been detected, causing incidents that activated the radiological emergency response system. In this sense, since some years ago, our country has been working in the implementation of a national and ministerial system for facing and mitigating the consequences of accidental radiological situations, conjugating efforts and wills from different national institutions with the leadership of the Center of Radiation Protection and Hygiene (CPHR) and the Center of Nuclear Security (CNSN) in correspondence with the social responsibility assigned to the them. These incidents propitiate to have not only a system of capacity and quick response oriented to limit the exposure of people, to control the sources, to mitigate the consequences of the accident and to reestablish the conditions of normality, but also a previous adequate planning that guarantees the speed and effectiveness of it. In these work the experiences reached by the specialists of the CPHR from Cuba during the occurrence of an incident in the execution of the service of radiological monitoring of scraps are exposed. (author)
Building for tomorrow today: opportunities and directions in radiology resident research.
Yu, John-Paul J; Kansagra, Akash P; Thaker, Ashesh; Colucci, Andrew; Sherry, Steven J; Subramaniam, Rathan M
2015-01-01
With rapid scientific and technological advancements in radiological research, there is renewed emphasis on promoting early research training to develop researchers who are capable of tackling the hypothesis-driven research that is typically funded in contemporary academic research enterprises. This review article aims to introduce radiology residents to the abundant radiology research opportunities available to them and to encourage early research engagement among trainees. To encourage early resident participation in radiology research, we review the various research opportunities available to trainees spanning basic, clinical, and translational science opportunities to ongoing research in information technology, informatics, and quality improvement research. There is an incredible breadth and depth of ongoing research at academic radiology departments across the country, and the material presented herein aspires to highlight both subject matter and opportunities available to radiology residents eager to engage in radiologic research. The opportunities for interested radiology residents are as numerous as they are broad, spanning the basic sciences to clinical research to informatics, with abundant opportunities to shape our future practice of radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
Dosimetry in diagnosis examinations in radiology
International Nuclear Information System (INIS)
Lisbona, Albert; Aubert, Bernard; Laffont, Sophie; Beaumont, Stephane; Catala, Alexandre; Cohard, Cecile; Cordoliani, Yves-Sebastien; Giraud, Jean-Yves; Lescrainier, Jacques; Noel, Alain; Verdun, Francis R.
2003-01-01
This document aims at helping the professionals involved in radiology when assessing the delivered doses to patients during conventional radiology examinations, in mammography and scanography. The first part recalls all the dosimetric data susceptible to characterize the X ray beam, the patient exposure and the radiological risk. The second part addresses the different types of sensors which can be used to obtain the different measurable dosimetric values. The third part presents the calculation, analytical and numerical methods. The fourth part proposes a set of sheets of data to be acquired on an installation to perform a measurement and/or a dose calculation
Organizational decentralization in radiology.
Aas, I H Monrad
2006-01-01
At present, most hospitals have a department of radiology where images are captured and interpreted. Decentralization is the opposite of centralization and means 'away from the centre'. With a Picture Archiving and Communication System (PACS) and broadband communications, transmitting radiology images between sites will be far easier than before. Qualitative interviews of 26 resource persons were performed in Norway. There was a response rate of 90%. Decentralization of radiology interpretations seems less relevant than centralization, but several forms of decentralization have a role to play. The respondents mentioned several advantages, including exploitation of capacity and competence. They also mentioned several disadvantages, including splitting professional communities and reduced contact between radiologists and clinicians. With the new technology decentralization and centralization of image interpretation are important possibilities in organizational change. This will be important for the future of teleradiology.
2012-01-01
by Dr. Helmut Vincke (CERN), Chris Theis (CERN). Tuesday, October 30, 2012 from 15:00 to 16:30 at CERN ( 864-1-D02 - BE Auditorium Prévessin ) Description: The operation of a high-energy accelerator inevitably triggers the activation of equipment, which poses a safety hazard. Consequently access and handling constraints have to be imposed to ensure optimized working conditions. One of the key parameters determining the level of radioactivity is the material composition. Considering the radiological impact in addition to the engineering requirements during the selection of material clearly results in a safety benefit as well as a more efficient accelerator operation due to less stringent access and handling constraints. Another aspect is the minimization of future radioactive waste, which constitutes an important part of CERN’s commitment to limit its environmental impact by applying best practices. The ActiWiz software developed at CERN provides an easy to use method to optimize the m...
International Nuclear Information System (INIS)
Martinez A, C.G.; Peregrina M, A.
1991-01-01
The particular details of each one of the applications of radioactive materials are presented with the purpose of forming conscience on the application of procedures and appropriate standards of radiological protection with the purpose of diminishing to the minimum expression the risks that result in the non energy applications of the ionizing radiations
Integrative teaching in radiology - a survey.
Dettmer, S; Weidemann, J; Fischer, V; Wacker, F K
2015-04-01
To survey integrative teaching in radiology at German universities. A questionnaire about radiological education was sent electronically to all 37 chairpersons of university radiology departments in Germany. The questions included the course type, teaching methods, concept, perception, and advantages and disadvantages of integrative teaching. Statistical analysis was performed with nonparametric statistics and chi-square test. The survey was considered representative with a return rate of 68 %. Integrative teaching is established at 4/5 of all departments. Integrative teaching is well accepted with an acceptance rate that is significantly higher in so-called "Modellstudiengängen" [model courses of study] (100 %) compared to conventional courses of study (72 %). The advantages of integrative teaching include linking of content (92 %) and preparation for interdisciplinary work (76 %). The disadvantages include high effort (75 %) and time (67 %) for organization. Furthermore, there is a risk that basic radiological facts and knowledge cannot be conveyed and that the visibility of radiology as an independent discipline is lost. Conventional radiological teaching has a similarly high acceptance (84 %) compared to integrative courses (76 %). Integrative teaching has a high acceptance among chairpersons in radiology in Germany despite the greater effort. A good interdisciplinary collaboration is essential for integrative teaching and at the same time this can be conveyed to the students. However, the visibility of radiology as a discipline and the possibility to cover basic radiological content must be ensured. Therefore, both conventional courses and integrative teaching seems reasonable, especially in cross-disciplinary subjects such as radiology. Both integrative teaching and conventional radiological teaching are highly accepted. The advantages include the linking of multidisciplinary content and the preparation for interdisciplinary cooperation
Hassanpour, Saeed; Langlotz, Curtis P; Amrhein, Timothy J; Befera, Nicholas T; Lungren, Matthew P
2017-04-01
The purpose of this study is to evaluate the performance of a natural language processing (NLP) system in classifying a database of free-text knee MRI reports at two separate academic radiology practices. An NLP system that uses terms and patterns in manually classified narrative knee MRI reports was constructed. The NLP system was trained and tested on expert-classified knee MRI reports from two major health care organizations. Radiology reports were modeled in the training set as vectors, and a support vector machine framework was used to train the classifier. A separate test set from each organization was used to evaluate the performance of the system. We evaluated the performance of the system both within and across organizations. Standard evaluation metrics, such as accuracy, precision, recall, and F1 score (i.e., the weighted average of the precision and recall), and their respective 95% CIs were used to measure the efficacy of our classification system. The accuracy for radiology reports that belonged to the model's clinically significant concept classes after training data from the same institution was good, yielding an F1 score greater than 90% (95% CI, 84.6-97.3%). Performance of the classifier on cross-institutional application without institution-specific training data yielded F1 scores of 77.6% (95% CI, 69.5-85.7%) and 90.2% (95% CI, 84.5-95.9%) at the two organizations studied. The results show excellent accuracy by the NLP machine learning classifier in classifying free-text knee MRI reports, supporting the institution-independent reproducibility of knee MRI report classification. Furthermore, the machine learning classifier performed well on free-text knee MRI reports from another institution. These data support the feasibility of multiinstitutional classification of radiologic imaging text reports with a single machine learning classifier without requiring institution-specific training data.
Poul Erik Andersen's radiological work on Osteochondrodysplasias and interventional radiology
DEFF Research Database (Denmark)
Andersen, Poul Erik
2011-01-01
Hospital. His significant experience and extensive scientific work has led to many posts in the Danish Society of Interventional Radiology, the European Society of Radiology and the Cardiovascular and Interventional Radiological Society of Europe, where he is a fellow and has passed the European Board...... of Interventional Radiology - The European qualification in Interventional Radiology....
International Nuclear Information System (INIS)
Ferguston, C.D.; Ouagrham, S.B.
2002-01-01
An urgent need calls out for improved border security and export control systems in the Central Asian and Caucasus regions to prevent illicit nuclear and radioactive materials trafficking. Effective nuclear and radiological exports controls are essential because these regions contain numerous nuclear facilities and radioactive materials as well as lie at the crossroads between seekers and suppliers of technologies that could be employed in nuclear and radiological weapons. Porous and unprotected borders compound these concerns. Moreover, the states within these regions are struggling with forming new regulations and laws, obtaining sufficient portal monitoring equipment, training customs and border security personnel, and coordinating these activities with neighboring states. Building this infrastructure all at once can severely task any government. Thus, unsurprisingly, most of these states have inadequate export control and border security systems. To enable each state in these regions determine how to better prevent illicit nuclear and radiological materials trafficking, the authors have developed a prototype system dynamics model focused on evaluating and improving of effectiveness of export controls. System dynamics modeling, a management tool that grew out of the field of system engineering and nonlinear dynamics, uses two structures: causal loop diagrams and stock and flow diagrams. The former shows how endogenous systematic factors interact with each other to produce feedback mechanisms that results in either balancing or reinforcing loops. A classic example is a arms race, modeled as a vicious cycle or reinforcing loop. In addition to interacting with each other, causal loops influence the flow of stock, which is material concern. In the export control system dynamics model, the stock represents nuclear and radioactive materials. System dynamics modelling is an iterative process that is continually modified by user input. Therefore, export control
Development of radiology in Mongolia
International Nuclear Information System (INIS)
Gonchigsuren, D.; Munkhbaatar, D.; Tuvshinjargal, D.; Onkhuudai, P.
2007-01-01
Full text: Radiology had been introduced in Mongolia by the establishment of the first X-Ray room at the First State Central Hospital in 1934. First radiologists in Mongolia were invited from the former Soviet Union; V. Sokolov, P. Omelchenko and others worked at the ''Burevestnik'' X-ray equipment of Russian production with high X-ray exposure and low capacity; they could perform only limited arts of Xray studies like fluoroscopy of thorax, stomach, esophagus and roentgenography of skull and extremities. The second X- ray equipment has been presented by the close friend of Lenin, the Director of People's Commissariat of Health Protection of the Soviet Union, Dr. N.A. Semashko; the present had been dedicated to the 10th Anniversary of Mongolian Health Care sector. During the military maneuvers at Khalkhin- Gol in 1939, several province hospitals and military hospitals had been supplied by the Xray equipment. During the period 1959-1960 all province hospitals, specialized hospitals had got X-ray unit. In 1955, Radii 226 had been used at first time in Mongolia for a treatment. In 1959, the State Radiological Clinic had been founded as a branch of X-ray cabinet of the First State Central Hospital. By the initiative of the absolvent of University of Leipzig, German Democratic Republic, Dr. P. Onkhuudai, Laboratory of Nuclear Medicine was established on 31 PstP March 1975 at the First State Central Hospital, which performed urography, thyroid and liver studies using Iod-131, Au-198, Hg-203 isotopes. In 1982, the gamma-camera and radio immunological equipment had been donated by the World Health Organization, and the Laboratory of Nuclear Medicine had been reorganized into Department of Nuclear Laboratory. Afterwards, in 1992 CT and SPECT diagnostics had been introduced at the First State Central Hospital, therefore new possibilities for high quality radiological diagnostic in Mongolia had been created. In 2007 the Siemens Magnetom 0.3 Tesla had been installed at the
Machine Learning in Radiology: Applications Beyond Image Interpretation.
Lakhani, Paras; Prater, Adam B; Hutson, R Kent; Andriole, Kathy P; Dreyer, Keith J; Morey, Jose; Prevedello, Luciano M; Clark, Toshi J; Geis, J Raymond; Itri, Jason N; Hawkins, C Matthew
2018-02-01
Much attention has been given to machine learning and its perceived impact in radiology, particularly in light of recent success with image classification in international competitions. However, machine learning is likely to impact radiology outside of image interpretation long before a fully functional "machine radiologist" is implemented in practice. Here, we describe an overview of machine learning, its application to radiology and other domains, and many cases of use that do not involve image interpretation. We hope that better understanding of these potential applications will help radiology practices prepare for the future and realize performance improvement and efficiency gains. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Sampling on radiological protection training in diagnostic radiology
International Nuclear Information System (INIS)
Gaona, E.
2001-01-01
Radiological security aspects were evaluated in radiology departments from Mexico City. The study was carried out in two stages, the first one evaluated 40 departments just before the implementation of the new Official Mexican Standards related to Radiological Security and Quality Control in Radiology; in the second stage 33 departments were evaluated 2 years after those standards were implanted, showing a favorable impact of the training programs for the type of answers obtained [es
Workflow improvement and efficiency gain with near digitalization of a Radiology Department
International Nuclear Information System (INIS)
Langen, H.L.; Bielmeier, J.; Selbach, R.; Wittenberg, G.; Feustel, H.
2003-01-01
Purpose: To determine the temporal changes of the workflow caused by digitalization of the radiology department after installation of digital luminescence-radiography (DLR), a radiology information system (RIS) and picture archiving and communication system (PACS) at the Missionsaerztliche Klinik in April 2000. Materials and methods: In a comparative study, a workflow analysis by manual registration of different work steps was performed before (1999) and after (2001) digitalization of a radiology department. Results: The digitalization shortened the examination time for patients from a mean of 8 min to 5 min. The time the patient is absent from the emergency room did not change. Reporting radiographic examinations including comparison with previous studies begins earlier from a mean of 2 h 37 min to 17 min. Using PACS, 85.9% of all cases could be interpreted on the day of the examination (without PACS 41.2%) and 87.2% of the reports were completed the day after the examination (without PACS 64.5%). No time differences were found between reading conventional studies on the monitor or as soft-copy. Conclusion: Compared to conventional film-screen systems, complete digitalization of a radiology department is time saving at nearly all steps of the workflow, with expected positive effects on the workflow quality of the entire hospital. (orig.) [de
TSD-DOSE : a radiological dose assessment model for treatment, storage, and disposal facilities
International Nuclear Information System (INIS)
Pfingston, M.
1998-01-01
In May 1991, the U.S. Department of Energy (DOE), Office of Waste Operations, issued a nationwide moratorium on shipping slightly radioactive mixed waste from DOE facilities to commercial treatment, storage, and disposal (TSD) facilities. Studies were subsequently conducted to evaluate the radiological impacts associated with DOE's prior shipments through DOE's authorized release process under DOE Order 5400.5. To support this endeavor, a radiological assessment computer code--TSD-DOSE (Version 1.1)--was developed and issued by DOE in 1997. The code was developed on the basis of detailed radiological assessments performed for eight commercial hazardous waste TSD facilities. It was designed to utilize waste-specific and site-specific data to estimate potential radiological doses to on-site workers and the off-site public from waste handling operations at a TSD facility. The code has since been released for use by DOE field offices and was recently used by DOE to evaluate the release of septic waste containing residual radioactive material to a TSD facility licensed under the Resource Conservation and Recovery Act. Revisions to the code were initiated in 1997 to incorporate comments received from users and to increase TSD-DOSE's capability, accuracy, and flexibility. These updates included incorporation of the method used to estimate external radiation doses from DOE's RESRAD model and expansion of the source term to include 85 radionuclides. In addition, a detailed verification and benchmarking analysis was performed
Radiological Findings in Children with Acute Pneumonia: Age More Important Than Infectious Agent
International Nuclear Information System (INIS)
Wahlgren, H.; Mortensson, W.; Eriksson, M.; Finkel, Y.; Forsgren, M.; Leinonen, M.
2005-01-01
Purpose: To evaluate whether radiological findings and healing time in children with pneumonia are correlated to etiologic agent. Material and Methods: A total of 346 children with radiologically verified acute pneumonia, and with accomplished serological tests for bacteria and viruses, were included in the study. Five etiological groups were analysed: children with bacterial etiology only, with viral etiology only, with mixed bacterial and viral etiology, with Mycoplasma only, and children with no etiology. Results: The chest films of each etiological group were analysed and the findings were correlated to the children's age. The radiological findings did not differ between the etiological groups. Radiological findings correlated significantly with the patient's age. The radiological healing frequency at check-up X-ray was found to be significantly lower in children with mixed bacterial and viral etiology compared to children in each of the other groups and to the material as a whole. Conclusion: Conclusions about the etiology could not be drawn from the chest X-ray findings
Webb, Emily M; Vella, Maya; Straus, Christopher M; Phelps, Andrew; Naeger, David M
2015-04-01
There are little data as to whether appropriate, cost effective, and safe ordering of imaging examinations are adequately taught in US medical school curricula. We sought to determine the proportion of noninterpretive content (such as appropriate ordering) versus interpretive content (such as reading a chest x-ray) in the top-selling medical student radiology textbooks. We performed an online search to identify a ranked list of the six top-selling general radiology textbooks for medical students. Each textbook was reviewed including content in the text, tables, images, figures, appendices, practice questions, question explanations, and glossaries. Individual pages of text and individual images were semiquantitatively scored on a six-level scale as to the percentage of material that was interpretive versus noninterpretive. The predominant imaging modality addressed in each was also recorded. Descriptive statistical analysis was performed. All six books had more interpretive content. On average, 1.4 pages of text focused on interpretation for every one page focused on noninterpretive content. Seventeen images/figures were dedicated to interpretive skills for every one focused on noninterpretive skills. In all books, the largest proportion of text and image content was dedicated to plain films (51.2%), with computed tomography (CT) a distant second (16%). The content on radiographs (3.1:1) and CT (1.6:1) was more interpretive than not. The current six top-selling medical student radiology textbooks contain a preponderance of material teaching image interpretation compared to material teaching noninterpretive skills, such as appropriate imaging examination selection, rational utilization, and patient safety. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
International Nuclear Information System (INIS)
Real, A.; Cruz, T. de la; Girona, L.; Montesinos, L.; Sanchez, P.
2012-01-01
The Training Department of the Spanish Nuclear Industry Forum has undertaken a new project to develop an interactive educational material on Radiological Protection. The objective was to develop an attractive, comprehensive and interactive material, to facilitate students and teachers of Elementary, Middle and High schools, to become familiar with ionising radiations. The novelly of the project, is that based on the European framework of key competencies for file long learning, which are defined as a set of knowledge, skills and altitudes that all individuals need for personal fulfilment and employment. The material presented in this paper, is based in an integrated structure of tasks, activities and exercises, which will facilitate the acquisition of as may key competencies as possible. Besides, the material also includes reference texts, links to pertinent web sites and videos. Students, through the development of a specific task (and related activities and exercises), will learn the differences between ionizing and non ionising radiation, the origin, characteristics and types of types of ionising radiation, how to detect and measure them, the potential detrimental health effects, the principles of radiation protection and the beneficial applications can have for man. The material is freely available in www.rinconeducativo.org. (Author) 4 refs.
Assessment of the radiological risks of road transport accidents involving type A package shipments
International Nuclear Information System (INIS)
Lange, F.; Fett, H.J.; Schwarz, G.; Raffestin, D.; Schneider, T.; Gelder, R.; Hughes, J.S.; Shaw, K.B.; Hedberg, B.; Simenstad, P.; Svahn, B.; Hienen, J.F.A.; Jansma, R.
1998-01-01
This paper is an account of work performed within a multi-lateral research project on the radiological risks associated with the transportation of Type A packaged radioactive material. The research project has been performed on behalf of the European Commission and various national agencies of the participating countries and involved organizations and institutes of five EU Member States, France, Germany, The Netherlands, Sweden, and the UK. The main objectives of the research project were the assessment and appraisal of the potential radiological risks of road transport accidents involving Type A package shipments in participating EU Member States. Data were collected and include harmonized sets information related to the type, quantity and characteristics of Type A package shipments by road. Such databases were basically non-existent until recently. The results are expected to be valuable to both national agencies and international organizations, with responsibilities for the safe transport of radioactive materials by providing some insight in the carriage of radioactive materials by road making up a major fraction of radioactive material transports. Similarly, a wide body of information has been collected and compiled on road transport accidents in terms of the frequency of occurrence and the severity of accidental impact loads potentially experienced by a Type A package.In addition, the results will facilitate judgement of the adequacy of the IAEA Transport Regulations as far as Type A packages are concerned. (O.M.)
Energy Technology Data Exchange (ETDEWEB)
Lopes, Amanda Gomes
2015-07-01
The handling of glassware in ampoules, containing solution is very common in research or production laboratories. During manipulation, there is a likelihood of occurrence of incidents such as the breaking of ampoules or glass vials containing material in liquid or powdered form which may cause a wound to the possibility of contamination with handled material. When the solution is radioactive there is a concern due to the risk of incorporation of that material. According to NCRP 156, the scientific literature contains over 2100 cases of wounds contaminated with radionuclides and more than 90% of the reported cases occurred in the hands and arms, but mainly on the fingers. Despite having no cases of wounds reported radioactive material in Brazil or a protocol developed by the National Agencies, applications and hence the manipulation of radionuclides is increasing in the country, rising the possibility of wound occurrence contaminated by radionuclides. In this work was proposed a methodology for management of individuals who suffered wounds from radioactive material in cases of nuclear accidents and radiological emergencies that present intake, which consisted of four steps: definition of the accident scenario, individual triage of the public or workers, proper measurements with detectors PRD, IdentiFINDER2 and germanium in different thicknesses material tissue-equivalent, and later adoption of first aid measures consisting of attendance, monitoring of contaminated personnel, evaluation of effective dose and direct to specialized medical center. As an example of results it follows the case of {sup 241}Am where the best performance was obtained by measurements with the shielded HPGe (7%) and the shielded and collimation of 0.5 cm IdentiFINDER2 (10%). While, unshielded PRD, unshielded or shielded side IdentiFINDER2 and unshielded TeCd showed performance ranging from 30 to 70%. In general, the uncertainties obtained had values below 1.5%. In this work a protocol for
Chronicle of pediatric radiology
International Nuclear Information System (INIS)
Benz-Bohm, Gabriele; Richter, Ernst
2012-01-01
The chronicle of pediatric radiology covers the following issues: Development of pediatric radiology in Germany (BRD, DDR, pediatric radiological accommodations); development of pediatric radiology in the Netherlands (chronology and pediatric radiological accommodations); development of pediatric radiology in Austria (chronology and pediatric radiological accommodations); development of pediatric radiology in Switzerland (chronology and pediatric radiological accommodations).
The American Board of Radiology Maintenance of Certification (MOC) Program in Radiologic Physics
International Nuclear Information System (INIS)
Thomas, Stephen R.; Hendee, William R.; Paliwal, Bhudatt R.
2005-01-01
Maintenance of Certification (MOC) recognizes that in addition to medical knowledge, several essential elements involved in delivering quality care must be developed and maintained throughout one's career. The MOC process is designed to facilitate and document the professional development of each diplomate of The American Board of Radiology (ABR) through its focus on the essential elements of quality care in Diagnostic Radiology and its subspecialties, and in the specialties of Radiation Oncology and Radiologic Physics. The initial elements of the ABR-MOC have been developed in accord with guidelines of The American Board of Medical Specialties. All diplomates with a ten-year, time-limited primary certificate in Diagnostic Radiologic Physics, Therapeutic Radiologic Physics, or Medical Nuclear Physics who wish to maintain certification must successfully complete the requirements of the appropriate ABR-MOC program for their specialty. Holders of multiple certificates must meet ABR-MOC requirements specific to the certificates held. Diplomates with lifelong certificates are not required to participate in the MOC, but are strongly encouraged to do so. MOC is based on documentation of individual participation in the four components of MOC: (1) professional standing, (2) lifelong learning and self-assessment, (3) cognitive expertise, and (4) performance in practice. Within these components, MOC addresses six competencies: medical knowledge, patient care, interpersonal and communication skills, professionalism, practice-based learning and improvement, and systems-based practice
Radiological error: analysis, standard setting, targeted instruction and teamworking
International Nuclear Information System (INIS)
FitzGerald, Richard
2005-01-01
Diagnostic radiology does not have objective benchmarks for acceptable levels of missed diagnoses [1]. Until now, data collection of radiological discrepancies has been very time consuming. The culture within the specialty did not encourage it. However, public concern about patient safety is increasing. There have been recent innovations in compiling radiological interpretive discrepancy rates which may facilitate radiological standard setting. However standard setting alone will not optimise radiologists' performance or patient safety. We must use these new techniques in radiological discrepancy detection to stimulate greater knowledge sharing, targeted instruction and teamworking among radiologists. Not all radiological discrepancies are errors. Radiological discrepancy programmes must not be abused as an instrument for discrediting individual radiologists. Discrepancy rates must not be distorted as a weapon in turf battles. Radiological errors may be due to many causes and are often multifactorial. A systems approach to radiological error is required. Meaningful analysis of radiological discrepancies and errors is challenging. Valid standard setting will take time. Meanwhile, we need to develop top-up training, mentoring and rehabilitation programmes. (orig.)
Standard practice for radiological examination using digital detector arrays
American Society for Testing and Materials. Philadelphia
2010-01-01
1.1 This practice establishes the minimum requirements for radiological examination for metallic and nonmetallic material using a digital detector array (DDA) system. 1.2 The requirements in this practice are intended to control the quality of radiologic images and are not intended to establish acceptance criteria for parts or materials. 1.3 This practice covers the radiologic examination with DDAs including DDAs described in Practice E2597 such as a device that contains a photoconductor attached to a Thin Film Transistor (TFT) read out structure, a device that has a phosphor coupled directly to an amorphous silicon read-out structure, and devices where a phosphor is coupled to a CMOS (Complementary metal–oxide–semiconductor) array, a Linear Detector Array (LDA) or a CCD (charge coupled device) crystalline silicon read-out structure. 1.4 The DDA shall be selected for an NDT application based on knowledge of the technology described in Guide , and of the selected DDA properties provided by the manufactu...
A model for radiological risk assessment from transportation of radioactive material
International Nuclear Information System (INIS)
Mancioppi, S.; Piermattei, S.
1985-01-01
The transport of radioactive materials is an important step in every practice involving the use of nuclear energy. The record of safety until now attained is undoubtedly satisfactory; however being large quantities of radioactive substances transported every day throughout the world, it was deemed worthwhile to evaluate the radiological impact connected with the transport of radioactive materials. The International Atomic Energy Agency, as the Agency issuing the Regulations applied by almost all the national and international transport organizations, sponsored a study aimed to develop a model for the evaluation of the risk connected with the transport activity. A code INTERTRAN (International Transport) has been developed by a Swedish research group (1) and is mainly based on a code (Radtran) developed at Sandia Labs. Other research groups like US and Italy offered their cooperation in the preparation of the code. It appears that the collective dose equivalents involved in the shipments of all wastes to their hypothetical final destination are rather low (40 person-rem in the worst case) and do not depend strongly from the transport mode. Handlers and crew are the most exposed group as it was expected, while the dose contribution to the general public is negligible. The situation could change in case of accident as accident dynamic and accident rate strongly depend on the mode of transport; it might happen that in this case one transport mode could be preferred to another. It is therefore deemed very important to deserve great attention to accident analysis, taking into account also the fact that there exists a category of flammable waste. Our future studies are oriented in this direction
Interventional radiology; Diagnostic radiology; X-ray imaging ... DIAGNOSTIC RADIOLOGY Diagnostic radiology helps health care professionals see structures inside your body. Doctors that specialize in the interpretation ...
Radiological Protection and Nuclear Engineering Studies in Multi-MW Target Systems
Luis, Raul Fernandes
Several innovative projects involving nuclear technology have emerged around the world in recent years, for applications such as spallation neutron sources, accelerator-driven systems for the transmutation of nuclear waste and radioactive ion beam (RIB) production. While the available neutron Wuxes from nuclear reactors did not increase substantially in intensity over the past three decades, the intensities of neutron sources produced in spallation targets have increased steadily, and should continue to do so during the 21st century. Innovative projects like ESS, MYRRHA and EURISOL lie at the forefront of the ongoing pursuit for increasingly bright neutron sources; driven by proton beams with energies up to 2 GeV and intensities up to several mA, the construction of their proposed facilities involves complex Nuclear Technology and Radiological Protection design studies executed by multidisciplinary teams of scientists and engineers from diUerent branches of Science. The intense neutron Wuxes foreseen for those facilities can be used in several scientiVc research Velds, such as Nuclear Physics and Astrophysics, Medicine and Materials Science. In this work, the target systems of two facilitites for the production of RIBs using the Isotope Separation On-Line (ISOL) method were studied in detail: ISOLDE, operating at CERN since 1967, and EURISOL, the next-generation ISOL facility to be built in Europe. For the EURISOL multi-MW target station, a detailed study of Radiological Protection was carried out using the Monte Carlo code FLUKA. Simulations were done to assess neutron Wuences, Vssion rates, ambient dose equivalent rates during operation and after shutdown and the production of radioactive nuclei in the targets and surrounding materials. DiUerent materials were discussed for diUerent components of the target system, aiming at improving its neutronics performance while keeping the residual activities resulting from material activation as low as possible. The second
Development of gonad protectors to be used in children radiology from recycled materials
International Nuclear Information System (INIS)
Sousa, C.H.S.; Teixeira, G.J.; Peixoto, J.G.P.; Menezes, I.V.; Medeiros, D.O.; Nunes, M.M.; Pinheiro, R.A.; Bernardes, P.M.B.; Oliveira, D.
2014-01-01
The use of medical radiology as a diagnostic tool has become a common practice and its benefits are undeniable, however, the radiological protection of patients has become a constant concern of the international community. Since children have a longer life expectancy, the risks of stochastic effects increase significantly. Thus, this study developed and designed gonads protectors, taking into account the anatomy, dimensions and ages of pediatric patients, reducing exposure to the primary beam by 94%. Furthermore, as a result of a secondary objective,success was obtained in reusing discarded as defective aprons. (author)
Radiological response of ceramic and polymeric devices for breast brachytherapy
International Nuclear Information System (INIS)
Batista Nogueira, Luciana; Passos Ribeiro de Campos, Tarcisio
2012-01-01
In the present study, the radiological visibility of ceramic and polymeric devices implanted in breast phantom was investigated for future applications in brachytherapy. The main goal was to determine the radiological viability of ceramic and polymeric devices in vitro by performing simple radiological diagnostic methods such as conventional X-ray analysis and mammography due to its easy access to the population. The radiological response of ceramic and polymeric devices implanted in breast phantom was determined using conventional X-ray, mammography and CT analysis. - Highlights: ► Radiological visibility of ceramic and polymeric devices implanted in breast phantom. ► The barium incorporation in the seed improves the radiological contrast. ► Radiological monitoring shows the position, orientation and degradation of devices. ► Simple radiological methods such as X-ray and mammography were used for radiological monitoring.
Anesthesia for radiologic procedures
International Nuclear Information System (INIS)
Forestner, J.E.
1987-01-01
Anesthetic techniques for neurodiagnostic studies and radiation therapy have been recently reviewed, but anesthetic involvement in thoracic and abdominal radiology has received little attention. Patient reactions to radiologic contrast media may be of concern to the anesthesiologist, who is often responsible for injecting these agents during diagnostic procedures, and thus is included in this discussion. Finally, the difficulties of administering anesthesia for magnetic resonance imaging (MRI) scans are outlined, in an effort to help anesthesiologist to anticipate problems with this new technologic development. Although there are very few indications for the use of general anesthesia for diagnostic radiologic studies in adults, most procedures performed with children, the mentally retarded, or the combative adult require either heavy sedation or general anesthesia. In selecting an anesthetic technique for a specific procedure, both the patient's disease process and the requirements of the radiologist must be carefully balanced
Anesthesia for interventional radiology
International Nuclear Information System (INIS)
van Sonnenberg, E.; Casola, G.; Varney, R.R.; D'Agostino, H.B.; Zornow, M.; Mazzie, W.
1989-01-01
We recognized that the complexity and surgical nature of many interventional radiology procedures dictate essential radiologic involvement into traditional anesthesiologic areas. They reviewed our experience with a variety of interventional procedures to document complications and problems related to anesthetic use (or misuse) and compile recommendations for rational monitoring and control for these procedures. In particular, the authors have studied complications of drug therapies and the treatment of these complications; use of complex anesthesia procedures (e.g., epidural anesthesia, succinylcholine blockage); reasons for choice of drugs (e.g., fentanyl vs meperidine vs morphine); and medico-legal aspects of radiologist performing traditional anesthesiology-type procedures
Energy Technology Data Exchange (ETDEWEB)
Ribes, R. [Hospital Reina Sofia, Cordoba (Spain). Servicio de Radiologia; Ros, P.R. [Harvard Medical School, Boston, MA (United States). Div. of Radiology
2007-07-01
The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)
International Nuclear Information System (INIS)
Ribes, R.; Ros, P.R.
2007-01-01
The book is an introductory book to radiological English on the basis that there are a lot of radiologists, radiology residents, radiology nurses, radiology students, and radiographers worldwide whose English level is indeterminate because their reading skills are much higher than their fluency. It is intended to help those health care professionals who need English for their work but do not speak English on a day-to-day basis. (orig.)
International Nuclear Information System (INIS)
Enyinna, P.I.; Avwiri, G. O.
2011-01-01
This research study is aimed at carrying out radiometric analyses of the natural radioactivity resulting from the presence of radionuclides in dolerite and kaolin which are raw materials widely used in construction works. The activity concentrations of the identified natural radionuclides of 226 Ra, 228 Ra and 40 K in 40 samples of these solid minerals collected from 4 mining sites were determined by gamma ray spectroscopic technique using a well calibrated [NaI(Tl)] detector. The mean values of the activity concentrations of 226 Ra, 228 Ra and 40 K for the dolerite samples were found to be 10.989Bq/kg, 6.956Bq/kg, 723.253Bq/kg and 10.735Bq/kg, 6.175Bq/kg, 714.895Bq/kg respectively (for the 2 dolerite mining sites); and for the kaolin samples, 8.507Bq/kg, 7.33Bq/kg, 87.511Bq/kg and 8.416Bq/kg, 7.354Bq/kg, 86.727Bq/kg respectively (for the 2 kaolin mining sites). The radium equivalent activity, the absorbed dose rate, the equivalent dose rate, the external and internal hazard indices, the annual outdoor and indoor effective dose rates were computed and compared with international radiological standards to ascertain if these minerals pose any radiological hazard. The results obtained were found to conform within the limits of acceptable international radiological standards and may not pose any immediate threat to the public and users of these two solid minerals for construction works.
Assessment of the radiological quality of tap waters 2008-2009
International Nuclear Information System (INIS)
Caamano, Delphine; Tracol, Raphael; Guillotin, Laetitia; Jedor, Beatrice; Davezac, Henri; Loyen, Jeanne
2011-06-01
After a recall of the context (radioactivity, origin of natural radioactivity in waters, exposure of population to natural radioactivity and health impact, indicators of water radiological quality, presence of uranium in water), this document reports a study which is based on the health control of water radiological quality by regional health agencies, on the analysis of natural and artificial radionuclides, on a survey on tap water radiological quality performed in 2009 by regional health agencies, and on an inventory of results related to the presence of radon in water performed by the IRSN and these agencies. The obtained results are presented and discussed in terms of factors impacting the result representativeness, of generalisation of the implementation of a health control, of tap water radiological quality. It is outlined that the uranium-related chemical risk is higher than the radiological risk
van der Gijp, A.; Ravesloot, C. J.; Jarodzka, H.; van der Schaaf, M. F.; van der Schaaf, I. C.; van Schaik, J. P.; ten Cate, Th. J.
2017-01-01
Eye tracking research has been conducted for decades to gain understanding of visual diagnosis such as in radiology. For educational purposes, it is important to identify visual search patterns that are related to high perceptual performance and to identify effective teaching strategies. This review of eye-tracking literature in the radiology…
Planning for a radiological emergency in health care institutions
International Nuclear Information System (INIS)
Jerez Vegueria, S.F.; Jerez Vegueria, P.F.
1998-01-01
The possible occurrence of accidents involving sources of ionizing radiation calls for response plans to mitigate the consequences of radiological accidents. An emergency planning framework is suggested for institutions which use medical applications of ionizing radiation. Bearing in mind that the prevention of accidents is of prime importance in dealing with radioactive materials and other sources of ionizing radiation, it is recommended that emergency instructions and procedures address certain aspects of the causes of these radiological events. Issues such as identification of radiological events in medical practices and their consequences, protective measures, planning for an emergency response and maintenance of emergency capacity are considered. (author)
International Nuclear Information System (INIS)
Goske, Marilyn J.; Smith, Susan N.; Charkot, Ellen; Herrmann, Tracy; John, Susan D.; Mills, Thalia T.; Morrison, Gregory
2011-01-01
The development of digital radiography (DR) has provided numerous benefits for pediatric imaging, including the ability to post-process images and to make images immediately available for access by care providers. However, DR presents several significant challenges for the radiologic technologists who are responsible for operating the equipment and producing high-quality images in children. This paper discusses those challenges, including lack of standardization among vendors, particularly with regard to the exposure indicator; lack of pediatric-specific educational materials and pediatric techniques; the need for manual technique instead of the use of automatic exposure control in smaller children; and complications related to field size, collimation and shielding in small children. Specific actions and design modifications that might facilitate the effective management of these challenges will be also described. The implementation of measures to promote the production of optimal images while minimizing radiation exposure requires cooperation and communication among imaging professionals, manufacturers and regulatory agencies. (orig.)
International Nuclear Information System (INIS)
Kirks, D.R.; Chaffee, D.J.
1990-01-01
This paper develops a relative scale of value for pediatric radiology (RSVPR). Neither the HCFA/ACA Relative Value Scale nor the Workload Measurement System developed by Health and Welfare Canada specifically addressed pediatric radiologic examinations. Technical and professional charges for examinations at Children's Hospital Medical Center were reviewed and compared with time and cost analysis. A scale was developed with chest radiography (PA and lateral views) assigned a value of 1. After review by pediatric radiologic technologists, radiologic administrators, pediatric radiologists, and chairs of departments of children's hospitals, this proposed scale was modified to reflect more accurately relative value components of pediatric radiologic and imaging examinations
Energy Technology Data Exchange (ETDEWEB)
Andrea, H.; Juliana, C.; Gerusa, R.; Laurete, M.B.; Suelen, S., E-mail: andrea.huhn@ifsc.edu.br, E-mail: juliana@ifsc.edu.br, E-mail: gerusa@ifsc.edu.br, E-mail: laurete@ifsc.edu.br, E-mail: suelen.saraiva@ifsc.edu.br [Instituto Federal de Santa Catarina (IFSC), Florianopolis, SC (Brazil); Derech, Rodrigo D.A., E-mail: dagostiniderech@gmail.com [Policlinica Municipal Sul, Florianopolis, SC (Brazil)
2013-11-01
The discovery of X-ray was a great achievement for humanity, especially for the medical community. In Intensive Care Units (ICUs), the RX tests, performed with mobile devices, add immense value to the diagnosis of inpatients who do not have the option to carry them out of bed. Following the technology and its improvements, fatalities arose from misuse of ionizing radiation, which mostly gave up for lack of knowledge of the biological effects caused by them, which leads to fear among professionals and often prevents a quick job and effectively by professionals of radiological techniques. The research it is a systematic review of the literature and justified by the scarcity of materials that reflect on the radiological protection in ICUs. For this study we found the Virtual Health Library (VHL) and Pubmed were indexed terms radiological protection and intensive care units, the search in Portuguese and English terms were used radiological protection and intensive care unit. The study aims to inform professionals of ICUs on the main aspects that refer to X-rays in hospital beds, the standards of radiological protection and personal protective equipment, thus avoiding possible damage to the biological health of workers, addressing subjects in rules and laws about the X radiation, emphasizing the protection of professionals in intensive care. It is clear, finally, that little research is conducted in the context of radiological protection of workers ICU's and this is a place that receives daily RX equipment, deserving more attention to protect the worker. (author)
Quality assurance program on diagnostic radiology
International Nuclear Information System (INIS)
Yacovenco, Alejandro; Borges, Jose Carlos; Mota, Helvecio Correa
1995-01-01
Aiming to elaborate a methodology to optimize the performance of the Radiology Service of the Military Police Hospital, in Rio de Janeiro, some goals were established: improvement of the attendance to patients; improvement of the qualification of technicians; achievement and maintenance of high degrees of quality in each step of the radiological process; improvement of the image quality; optimization of dose per examination and cost reduction. (author). 8 refs., 3 figs
Radiological anatomy - evaluation of integrative education in radiology.
Dettmer, S; Schmiedl, A; Meyer, S; Giesemann, A; Pabst, R; Weidemann, J; Wacker, F K; Kirchhoff, T
2013-09-01
Evaluation and analysis of the integrative course "Radiological Anatomy" established since 2007 at the Medical School Hannover (MHH) in comparison with conventional education. Anatomy and radiology are usually taught separately with a considerable time lag. Interdisciplinary teaching of these associated subjects seems logical for several reasons. Therefore, the integrative course "Radiological Anatomy" was established in the second year of medical education, combining these two closely related subjects. This interdisciplinary course was retrospectively evaluated by consideration of a student questionnaire and staff observations. The advantages and disadvantages of integrative teaching in medical education are discussed. The course ratings were excellent (median 1; mean 1.3 on a scale of 1 to 6). This is significantly (p radiology increased during the course (88 %). According to the students' suggestions the course was enhanced by a visitation in the Department of Radiology and the additional topic central nervous system. Integrative teaching of anatomy and radiology was well received by the students. Both, anatomical and radiological comprehension and the motivation to learn were improved. However, it should be considered, that the amount of work and time required by the teaching staff is considerably increased compared to traditional teaching. © Georg Thieme Verlag KG Stuttgart · New York.
Preventing radiological terrorism - opportunities and challenges
International Nuclear Information System (INIS)
Barlow, Maegon E.
2016-01-01
The Office of Radiological Security (ORS), within the U.S. Department of Energy's National Nuclear Security Administration, enhances global security by preventing high activity radioactive materials from use in acts of terrorism. This is a challenging task considering that high activity radiological materials are ubiquitous, constantly moving and mostly found in operational civil facilities. The implementation of the ORS mission is based on a three pillar strategy - protect, remove and reduce. ORS works both domestically and internationally with government authorities, law enforcement, and businesses to protect radioactive sources used for vital medical, research, and commercial purposes, remove and dispose of disused radioactive sources, and reduce the global reliance on radioactive sources through the promotion of viable non-isotopic alternative technologies. ORS has active engagement in all 50 States and in over 80 countries. This presentation will provide an overview of ORS protect, remove, and reduce strategy, as well as security challenges and opportunities
Guidelines for planning and design of mobile radiological units
Energy Technology Data Exchange (ETDEWEB)
Schelenz, R [Federal Office for Environmental Radioactivity in Food, Total Diet and Infant Food, Federal Research Centre for Nutrition, Karlsruhe (Germany)
1995-07-01
A significant number of mobile radiological units are in operation worldwide aiming to provide reliable radiological data. They mainly have been designed and constructed on a national basis according to the particular needs and commitments of the specific laboratory or country. In most cases, these units are intended to be used in emergency situations for in-situ radiological measurements of accidentally released radioactivity, sometimes for monitoring environmental pollution. As the purpose of these units is very diversified in regard to the kind of vehicle and its in-built measuring equipment the varying outfit of these units cannot be adopted in general for other countries aiming to improve their capability for in-situ radiological measurement. In order to achieve harmonization of equipment and comparability of radiological data being obtained from field measurements it is necessary to have general guidelines available for designing mobile radiological units taking into account different sceneries and tasks to be achieved. In the very early stages of an accident most of the information available on the quantity of radioactive material being released, its radionuclide composition and the likely progression of the accident will come from the operator, and will be based on the conditions in the plant. Few environmental monitoring results from off-side can be expected within the first few hours. In this very early phase, decisions on the application of protective measures will therefore, be based largely on plant status and forecasts of changes in that status as well as on meteorological data. As time progresses, results will increasingly become available from the monitoring of radionuclides in the environment (e.g. dose rates and concentration of radionuclides in air and particular materials such as water, food etc). Monitoring results can be used to estimate potential doses to people and the need for further protective measures can thus be determined from a
Guidelines for planning and design of mobile radiological units
International Nuclear Information System (INIS)
Schelenz, R.
1995-01-01
A significant number of mobile radiological units are in operation worldwide aiming to provide reliable radiological data. They mainly have been designed and constructed on a national basis according to the particular needs and commitments of the specific laboratory or country. In most cases, these units are intended to be used in emergency situations for in-situ radiological measurements of accidentally released radioactivity, sometimes for monitoring environmental pollution. As the purpose of these units is very diversified in regard to the kind of vehicle and its in-built measuring equipment the varying outfit of these units cannot be adopted in general for other countries aiming to improve their capability for in-situ radiological measurement. In order to achieve harmonization of equipment and comparability of radiological data being obtained from field measurements it is necessary to have general guidelines available for designing mobile radiological units taking into account different sceneries and tasks to be achieved. In the very early stages of an accident most of the information available on the quantity of radioactive material being released, its radionuclide composition and the likely progression of the accident will come from the operator, and will be based on the conditions in the plant. Few environmental monitoring results from off-side can be expected within the first few hours. In this very early phase, decisions on the application of protective measures will therefore, be based largely on plant status and forecasts of changes in that status as well as on meteorological data. As time progresses, results will increasingly become available from the monitoring of radionuclides in the environment (e.g. dose rates and concentration of radionuclides in air and particular materials such as water, food etc). Monitoring results can be used to estimate potential doses to people and the need for further protective measures can thus be determined from a
Ambulatory phlebectomy at radiologic outpatient clinic
International Nuclear Information System (INIS)
Yoon, Chang Jin; Kang, Sung Gwon; Choi, Sang Il; Lee, Whal; Chung, Jin Wook; Park, Jae Hyung
2007-01-01
To evaluate safety, efficacy, and patient's satisfaction of an ambulatory phlebectomy, performed at a radiology outpatient clinic. Between 2003 and 2006, an ambulatory phlebectomy was performed in 12 patients. Endovenous radiofrequency ablation was performed through a venotomy. The venotomy was ligated after RF ablation, and the ambulatory phlebectomy was performed. The patients visited the radiology outpatient clinic one day, one week, and 2 months after the procedure. The improvement in the clinical symptoms, cosmetic change in varicosity, and the procedure related complications were evaluated. The patient's satisfaction was evaluated using a 5-grade scale. RF ablation through a venotomy was performed successfully in all 12 patients. On average, 4.5 incisions were made, and 12.5 cm of varicosity had been removed. The mean procedure time was one hour and forty minutes. The complications of the ambulatory phlebectomy were bruising in one patient, and skin pigmentation in another. The complications associated with RF ablation were a hard palpable vein in 7 patients, numbness in 7 patients, and skin pigmentation along the vein in 2 patients. Follow-up duplex sonography was performed at 2 months after the procedure, showed complete occlusion in all 12 patients. The clinical symptoms had improved in 11 patients, and the varicosity disappeared cosmetically in 11 patients. An ambulatory phlebectomy, combined with RF ablation of the greater saphenous vein, can be performed safely and effectively at a radiology outpatient clinic
Ambulatory phlebectomy at radiologic outpatient clinic
Energy Technology Data Exchange (ETDEWEB)
Yoon, Chang Jin; Kang, Sung Gwon; Choi, Sang Il [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Lee, Whal; Chung, Jin Wook; Park, Jae Hyung [Seoul National University, Medical College, Seoul (Korea, Republic of)
2007-03-15
To evaluate safety, efficacy, and patient's satisfaction of an ambulatory phlebectomy, performed at a radiology outpatient clinic. Between 2003 and 2006, an ambulatory phlebectomy was performed in 12 patients. Endovenous radiofrequency ablation was performed through a venotomy. The venotomy was ligated after RF ablation, and the ambulatory phlebectomy was performed. The patients visited the radiology outpatient clinic one day, one week, and 2 months after the procedure. The improvement in the clinical symptoms, cosmetic change in varicosity, and the procedure related complications were evaluated. The patient's satisfaction was evaluated using a 5-grade scale. RF ablation through a venotomy was performed successfully in all 12 patients. On average, 4.5 incisions were made, and 12.5 cm of varicosity had been removed. The mean procedure time was one hour and forty minutes. The complications of the ambulatory phlebectomy were bruising in one patient, and skin pigmentation in another. The complications associated with RF ablation were a hard palpable vein in 7 patients, numbness in 7 patients, and skin pigmentation along the vein in 2 patients. Follow-up duplex sonography was performed at 2 months after the procedure, showed complete occlusion in all 12 patients. The clinical symptoms had improved in 11 patients, and the varicosity disappeared cosmetically in 11 patients. An ambulatory phlebectomy, combined with RF ablation of the greater saphenous vein, can be performed safely and effectively at a radiology outpatient clinic.
Enhancement of radiological protection through an internal quality assessment cycle
International Nuclear Information System (INIS)
Figueiredo, Filipe Morais de; Gama, Zenewton Andre da Silva
2012-01-01
Objective: To determine the level of quality in radiation protection of patients during radiological examination, evaluating the effectiveness of an intervention aimed at enhancing the quality of such a protection. Materials and Methods: A quality improvement cycle was implemented in a radiology service of the Regional Health Administration, in Algarve, Portugal. Based on six quality criteria, an initial evaluation was performed and followed by an intervention focused on the most problematic points (over an eight-month period) and a subsequent quality reassessment. A random sampling (n = 60) has allowed the authors to infer the point estimates and confidence intervals for each criterion, as well as calculating the statistical significance of the results by means of the Z-test. Results: Initially, deficiencies were observed in relation to all the quality criteria. After the intervention, a minimum relative improvement of 33% was observed in five of the six criteria, with statistical significance (p < 0.05) in two of them. The absolute frequency of noncompliance decreased from 38 (first evaluation) to 21 (second evaluation), corresponding to a 44.7% improvement. Conclusion: The first institutional evaluation cycle showed a seemingly incipient improvement margin. However, the implemented intervention was effective in stimulating good practices and improving the level of radiological protection of patients. (author)
Integrating technology into radiologic science education.
Wertz, Christopher Ira; Hobbs, Dan L; Mickelsen, Wendy
2014-01-01
To review the existing literature pertaining to the current learning technologies available in radiologic science education and how to implement those technologies. Only articles from peer-reviewed journals and scholarly reports were used in the research for this review. The material was further restricted to those articles that emphasized using new learning technologies in education, with a focus on radiologic science education. Teaching in higher education is shifting from a traditional classroom-based lecture format to one that incorporates new technologies that allow for more varied and diverse educational models. Radiologic technology educators must adapt traditional education delivery methods to incorporate current technologies. Doing so will help engage the modern student in education in ways in which they are already familiar. As students' learning methods change, so must the methods of educational delivery. The use of new technologies has profound implications for education. If implemented properly, these technologies can be effective tools to help educators.
Radiological control guide for decommissioning of the TRIGA mark-2, 3
International Nuclear Information System (INIS)
Lee, Bong Jae
2000-08-01
The purpose of radiological control for TRIGA mark-2, 3 research reactors and facilities at the KAERI Seoul site, which are to be decommissioned, is in minimizing the radiation exposure for workers and in preventing the release of the radioactive materials to the environment. In order to accomplish these goal, the radiological control guide will be prepared during the decommissioning activities. Therefore, it is expected that this technical report can be used in preparing radiological control guide for safety decommissioning of the TRIGA mark-2, 3
Schatzki ring in children and young adults: clinical and radiologic findings
Energy Technology Data Exchange (ETDEWEB)
Buckley, K.; Buonomo, C. [Department of Radiology, Children`s Hospital, Boston, MA (United States); Husain, K.; Nurko, S. [Division of Gastroenterology, Children`s Hospital, Boston, MA (United States)
1998-11-01
Background. The Schatzki ring is a well-known clinical and radiologic entity in adults, but is thought to be rare in childhood. Objective. To review the clinical presentations and radiologic findings of children and young adults with Schatzki rings. Materials and methods. A retrospective review of all barium swallow examinations done between 1990 and 1996 revealed 20 patients with Schatzki rings. Results. The most frequent presenting symptoms of these patients were progressive dysphagia with solid food and acute food impaction. Radiographic findings of Schatzki rings were typical in all cases. Twelve patients had endoscopy and all had evidence of esophagitis. Conclusion. Schatzki rings are not rare in childhood. The patients are symptomatic, presenting with either progressive dysphagia with solids or acute food impaction. A thorough evaluation of the distal esophagus should be performed in patients with a suggestive clinical history. (orig.) With 2 figs., 8 refs.
The clinical and radiological evaluation of absence of the corpus callosum
International Nuclear Information System (INIS)
Byrd, S.E.; Radkowski, M.A.; McLone, D.G.; Northwestern Univ., Chicago, IL; Flannery, A.
1990-01-01
A retrospective and prospective analysis of children with a diagnosis of complete absence of the corpus callosum (ACC) at the Children's Memorial Hospital in Chicago over a 5-year period was performed. The diagnosis was based on the computed tomography (CT) and/or magnetic resonance (MR) images. From this material, 105 children with a diagnosis of ACC were analyzed on the basis of clinical symptomatology and radiological studies (CT, MR and ultrasound). Eighty-three percent of our children were symptomatic. The most common symptoms and signs were macrocephaly with hydrocephalus and seizures. MR was the best radiological imaging modality for evaluating children with ACC and associated brain anomalies. The most common associated brain anomalies with ACC in decreasing frequency in our children were: interhemispheric cyst with hydrocephalus, Dandy-Walker malformation, migrational disorders, absence of the inferior vermis, cephaloceles and lipoma aof the interhemispheric fissure. (author). 15 refs.; 8 figs.; 2 tabs
Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Schoepf, U Joseph; Xu, Jiaqian; Lu, Guang Ming; Li, Enzhong
2017-10-01
To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. • Radiology research in Mainland China saw a substantial increase. • Neuroradiology, vascular/interventional Radiology, and abdominal Radiology are the most productive fields. • MRI is the most used modality in Mainland China's Radiology research. • Guangdong, Shanghai, and Beijing are the most productive provinces.
Radiological Findings in Children with Acute Pneumonia: Age More Important Than Infectious Agent
Energy Technology Data Exchange (ETDEWEB)
Wahlgren, H.; Mortensson, W.; Eriksson, M.; Finkel, Y.; Forsgren, M.; Leinonen, M. [Astrid Lindgren' s Children' s Hospital, Karolinska Hospital, Stockholm (Sweden). Depts. of Pediatric Radiology and Pediatrics
2005-07-01
Purpose: To evaluate whether radiological findings and healing time in children with pneumonia are correlated to etiologic agent. Material and Methods: A total of 346 children with radiologically verified acute pneumonia, and with accomplished serological tests for bacteria and viruses, were included in the study. Five etiological groups were analysed: children with bacterial etiology only, with viral etiology only, with mixed bacterial and viral etiology, with Mycoplasma only, and children with no etiology. Results: The chest films of each etiological group were analysed and the findings were correlated to the children's age. The radiological findings did not differ between the etiological groups. Radiological findings correlated significantly with the patient's age. The radiological healing frequency at check-up X-ray was found to be significantly lower in children with mixed bacterial and viral etiology compared to children in each of the other groups and to the material as a whole. Conclusion: Conclusions about the etiology could not be drawn from the chest X-ray findings.
The radiology perspective: needs and tools for management of life-threatening events
International Nuclear Information System (INIS)
Gaca, Ana Maria; Lerner, Catherine B.; Frush, Donald P.
2008-01-01
Studies have shown that life-threatening contrast agent reactions in adults are very rare, and even less common in children. The rarity of severe allergic reactions to contrast material challenges educators to achieve radiology resident competency in this setting. However, using a simulated anaphylactic contrast reaction paradigm, we have drawn two conclusions: (1) Residents are insufficiently prepared to recognize and manage these life-threatening events and (2) with an interactive, computer-based tool we can significantly improve resident performance in these situations. Simulation is a growing tool in medicine and allows standardized resident exposure to uncommon events in a setting that is conducive to resident education without fear of repercussions (see Ruddy and Patterson in this issue of Pediatric Radiology). More important, simulation provides a cornerstone in patient safety resident education without putting patients at risk. (orig.)
The radiology perspective: needs and tools for management of life-threatening events
Energy Technology Data Exchange (ETDEWEB)
Gaca, Ana Maria; Lerner, Catherine B.; Frush, Donald P. [Duke University Medical Center, Department of Radiology, Durham, NC (United States)
2008-11-15
Studies have shown that life-threatening contrast agent reactions in adults are very rare, and even less common in children. The rarity of severe allergic reactions to contrast material challenges educators to achieve radiology resident competency in this setting. However, using a simulated anaphylactic contrast reaction paradigm, we have drawn two conclusions: (1) Residents are insufficiently prepared to recognize and manage these life-threatening events and (2) with an interactive, computer-based tool we can significantly improve resident performance in these situations. Simulation is a growing tool in medicine and allows standardized resident exposure to uncommon events in a setting that is conducive to resident education without fear of repercussions (see Ruddy and Patterson in this issue of Pediatric Radiology). More important, simulation provides a cornerstone in patient safety resident education without putting patients at risk. (orig.)
Introduction of radiological protection; Pengenalan kepada perlindungan radiologi
Energy Technology Data Exchange (ETDEWEB)
NONE
1988-12-31
The chapter briefly discussed the following subjects: basic principles of radiological protection , dose limit which was suggested, stochastic and nonstochastic effects, equivalent dose and alternative of it`s calculation, limit for the publics, ICRP (International Commission for Radiological Protection) recommendations, and the principles of radiological protection. Dangerous radiation sources also briefly summarized i.e. x-ray generators, reactor nucleus.
Finding and evaluating potential radiological problems in the vicinity of uranium milling sites
International Nuclear Information System (INIS)
Goldsmith, W.A.; Yates, W.G.
1982-01-01
The Oak Ridge National Laboratory (ORNL) has been performing radiological surveys at former uranium and thorium milling and processing sites since 1975. Tailings at inactive milling sites usually have a low frequency of human occupancy but continuously generate 222 Rn into the atmosphere. Thus, independent 222 Rn surveys are conducted at the inactive mill sites and their environs by the Mound Facility. Measurements of airborne 222 Rn and 222 Rn flux are made on the sites to define the tailings source term. Concurrently with these measurements, an ambient 222 Rn monitoring network is established off-site and a meteorological station is established at or near the mill site. Unfortunately, tailings are not always confined to the milling site. Radioactivity can migrate to areas outside of site boundaries by wind and water erosion, groundwater transport, spillage of incoming ore, and removal of tailings or other material for private purposes. In order to identify and assess off-site radioactivity on properties in the vicinity of milling sites, a combination of aerial and ground-level radiological monitoring techniques are used. The ground mobile gamma-ray scan is conducted using a vehicle equipped with sensitive gamma-ray detectors. The detectors are shielded so that gamma radiation input is viewed through only one side of the vehicle. This system is capable of precisely locating properties which have anomalously high gamma radiation levels caused by the presence of tailings. Subsequently, these properties are identified as candidate vicinity properties and are scheduled for radiological surveys subject to the property owner's consent. The comprehensive radiological surveys conducted at these vicinity properties determine the amount, type, and location of tailings materials
Criteria for radiologic diagnosis of hypochondroplasia in neonates
Energy Technology Data Exchange (ETDEWEB)
Saito, Tomoko; Nagasaki, Keisuke; Wada, Masaki; Nyuzuki, Hiromi; Saitoh, Akihiko [Niigata University Graduate School of Medical and Dental Sciences, Division of Pediatrics, Department of Homeostatic Regulation and Development (Japan); Nishimura, Gen [Tokyo Metropolitan Children' s Medical Center, Department of Radiology, Tokyo (Japan); Takagi, Masaki [Tokyo Metropolitan Children' s Medical Center, Department of Endocrinology, Tokyo (Japan); Keio University School of Medicine, Department of Pediatrics, Tokyo (Japan); Hasegawa, Tomonobu; Amano, Naoko [Keio University School of Medicine, Department of Pediatrics, Tokyo (Japan); Murotsuki, Jun [Tohoku University Graduate School of Medicine, Miyagi Children' s Hospital, Department of Maternal and Fetal Medicine, Sendai (Japan); Sawai, Hideaki [Hyogo College of Medicine, Departments of Obstetrics and Gynecology, Hyogo (Japan); Yamada, Takahiro [Hokkaido University Hospital, Departments of Obstetrics and Gynecology, Hokkaido (Japan); Sato, Shuhei [Aomori Rosai Hospital, Department of Obstetrics and Gynecology, Aomori (Japan)
2016-04-15
A radiologic diagnosis of hypochondroplasia is hampered by the absence of age-dependent radiologic criteria, particularly in the neonatal period. To establish radiologic criteria and scoring system for identifying neonates with fibroblast growth factor receptor 3 (FGFR3)-associated hypochondroplasia. This retrospective study included 7 hypochondroplastic neonates and 30 controls. All subjects underwent radiologic examination within 28 days after birth. We evaluated parameters reflecting the presence of (1) short ilia, (2) squared ilia, (3) short greater sciatic notch, (4) horizontal acetabula, (5) short femora, (6) broad femora, (7) metaphyseal flaring, (8) lumbosacral interpedicular distance narrowing and (9) ovoid radiolucency of the proximal femora. Only parameters 1, 3, 4, 5 and 6 were statistically different between the two groups. Parameters 3, 5 and 6 did not overlap between the groups, while parameters 1 and 4 did. Based on these results, we propose a scoring system for hypochondroplasia. Two major criteria (parameters 3 and 6) were assigned scores of 2, whereas 4 minor criteria (parameters 1, 4, 5 and 9) were assigned scores of 1. All neonates with hypochondroplasia in our material scored ≥6. Our set of diagnostic radiologic criteria might be useful for early identification of hypochondroplastic neonates. (orig.)
Criteria for radiologic diagnosis of hypochondroplasia in neonates
International Nuclear Information System (INIS)
Saito, Tomoko; Nagasaki, Keisuke; Wada, Masaki; Nyuzuki, Hiromi; Saitoh, Akihiko; Nishimura, Gen; Takagi, Masaki; Hasegawa, Tomonobu; Amano, Naoko; Murotsuki, Jun; Sawai, Hideaki; Yamada, Takahiro; Sato, Shuhei
2016-01-01
A radiologic diagnosis of hypochondroplasia is hampered by the absence of age-dependent radiologic criteria, particularly in the neonatal period. To establish radiologic criteria and scoring system for identifying neonates with fibroblast growth factor receptor 3 (FGFR3)-associated hypochondroplasia. This retrospective study included 7 hypochondroplastic neonates and 30 controls. All subjects underwent radiologic examination within 28 days after birth. We evaluated parameters reflecting the presence of (1) short ilia, (2) squared ilia, (3) short greater sciatic notch, (4) horizontal acetabula, (5) short femora, (6) broad femora, (7) metaphyseal flaring, (8) lumbosacral interpedicular distance narrowing and (9) ovoid radiolucency of the proximal femora. Only parameters 1, 3, 4, 5 and 6 were statistically different between the two groups. Parameters 3, 5 and 6 did not overlap between the groups, while parameters 1 and 4 did. Based on these results, we propose a scoring system for hypochondroplasia. Two major criteria (parameters 3 and 6) were assigned scores of 2, whereas 4 minor criteria (parameters 1, 4, 5 and 9) were assigned scores of 1. All neonates with hypochondroplasia in our material scored ≥6. Our set of diagnostic radiologic criteria might be useful for early identification of hypochondroplastic neonates. (orig.)
International Nuclear Information System (INIS)
Edholm, P.R.
1990-01-01
This is a report describing diagnostic techniques used in radiology. It describes the equipment necessary for, and the operation of a radiological department. Also is described the standard methods used in radiodiagnosis. (K.A.E.)
Evidence-based radiology: why and how?
International Nuclear Information System (INIS)
Sardanelli, Francesco; Di Leo, Giovanni; Hunink, Myriam G.; Gilbert, Fiona J.; Krestin, Gabriel P.
2010-01-01
To provide an overview of evidence-based medicine (EBM) in relation to radiology and to define a policy for adoption of this principle in the European radiological community. Starting from Sackett's definition of EBM we illustrate the top-down and bottom-up approaches to EBM as well as EBM's limitations. Delayed diffusion and peculiar features of evidence-based radiology (EBR) are defined with emphasis on the need to shift from the demonstration of the increasing ability to see more and better, to the demonstration of a significant change in treatment planning or, at best, of a significant gain in patient outcome. The ''as low as reasonably achievable'' (ALARA) principle is thought as a dimension of EBR while EBR is proposed as part of the core curriculum of radiology residency. Moreover, we describe the process of health technology assessment in radiology with reference to the six-level scale of hierarchy of studies on diagnostic tests, the main sources of bias in studies on diagnostic performance, and levels of evidence and degrees of recommendations according to the Centre for Evidence-Based Medicine (Oxford, UK) as well as the approach proposed by the GRADE working group. Problems and opportunities offered by evidence-based guidelines in radiology are considered. Finally, we suggest nine points to be actioned by the ESR in order to promote EBR. Radiology will benefit greatly from the improvement in practice that will result from adopting this more rigorous approach to all aspects of our work. (orig.)
THE WORK PROCESS IN RADIOLOGICAL NURSING: INVISIBILITY OFIONIZING RADIATION
Melo,Juliana Almeida Coelho de; Gelbcke,Francine Lima; Huhn,Andrea; Vargas,Mara Ambrosina de Oliveira
2015-01-01
ABSTRACT Qualitative descriptive and exploratory research, performed with 20 nursing professionals working in a general radiology unit and surgery center with the "C-arm" equipment, and the hemodynamics unit of a southern Brazilian teaching hospital. Aim was to analyze the dimensions of the work process for radiological technology nurse professionals. This paper made clear that radiological technologies are outside nursing, which leads to the invisibility of ionizing radiation, leading to ina...
A reference standard-based quality assurance program for radiology.
Liu, Patrick T; Johnson, C Daniel; Miranda, Rafael; Patel, Maitray D; Phillips, Carrie J
2010-01-01
The authors have developed a comprehensive radiology quality assurance (QA) program that evaluates radiology interpretations and procedures by comparing them with reference standards. Performance metrics are calculated and then compared with benchmarks or goals on the basis of published multicenter data and meta-analyses. Additional workload for physicians is kept to a minimum by having trained allied health staff members perform the comparisons of radiology reports with the reference standards. The performance metrics tracked by the QA program include the accuracy of CT colonography for detecting polyps, the false-negative rate for mammographic detection of breast cancer, the accuracy of CT angiography detection of coronary artery stenosis, the accuracy of meniscal tear detection on MRI, the accuracy of carotid artery stenosis detection on MR angiography, the accuracy of parathyroid adenoma detection by parathyroid scintigraphy, the success rate for obtaining cortical tissue on ultrasound-guided core biopsies of pelvic renal transplants, and the technical success rate for peripheral arterial angioplasty procedures. In contrast with peer-review programs, this reference standard-based QA program minimizes the possibilities of reviewer bias and erroneous second reviewer interpretations. The more objective assessment of performance afforded by the QA program will provide data that can easily be used for education and management conferences, research projects, and multicenter evaluations. Additionally, such performance data could be used by radiology departments to demonstrate their value over nonradiology competitors to referring clinicians, hospitals, patients, and third-party payers. Copyright 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Assessing reader performance in radiology, an imperfect science: Lessons from breast screening
Energy Technology Data Exchange (ETDEWEB)
Soh, B.P., E-mail: bsoh6456@uni.sydney.edu.au [Medical Image Optimisation and Perception Group (MIOPeG), Faculty of Health Sciences, University of Sydney, Lidcombe, NSW (Australia); Lee, W.; Kench, P.L.; Reed, W.M.; McEntee, M.F.; Poulos, A.; Brennan, P.C. [Medical Image Optimisation and Perception Group (MIOPeG), Faculty of Health Sciences, University of Sydney, Lidcombe, NSW (Australia)
2012-07-15
The purpose of this article is to review the limitations associated with current methods of assessing reader accuracy in mammography screening programmes. Clinical audit is commonly used as a quality-assurance tool to monitor the performance of screen readers; however, a number of the metrics employed, such as recall rate as a surrogate for specificity, do not always accurately measure the intended clinical feature. Alternatively, standardized screening test sets, which benefit from ease of application, immediacy of results, and quicker assessment of quality improvement plans, suffer from experimental confounders, thus questioning the relevance of these laboratory-type screening test sets to clinical performance. Four key factors that impact on the external validity of screening test sets were identified: the nature and extent of scrutiny of one's action, the artificiality of the environment, the over-simplification of responses, and prevalence of abnormality. The impact of these factors on radiological and other contexts is discussed, and although it is important to acknowledge the benefit of standardized screening test sets, issues relating to the relevance of test sets to clinical activities remain. The degree of correlation between performance based on real-life clinical audit and performances at screen read test sets must be better understood and specific causal agents for any lack of correlation identified.
Marshall, Nina L; Spooner, Muirne; Galvin, P Leo; Ti, Joanna P; McElvaney, N Gerald; Lee, Michael J
2011-01-01
A preliminary audit of orders for computed tomography was performed to evaluate the typical performance of interns ordering radiologic examinations. According to the audit, the interns showed only minimal improvement after 8 months of work experience. The online radiology ordering module (ROM) program included baseline assessment of student performance (part I), online learning with the ROM (part II), and follow-up assessment of performance with simulated ordering with the ROM (part III). A curriculum blueprint determined the content of the ROM program, with an emphasis on practical issues, including provision of logistic information, clinical details, and safety-related information. Appropriate standards were developed by a committee of experts, and detailed scoring systems were devised for assessment. The ROM program was successful in addressing practical issues in a simulated setting. In the part I assessment, the mean score for noting contraindications for contrast media was 24%; this score increased to 59% in the part III assessment (P = .004). Similarly, notification of methicillin-resistant Staphylococcus aureus status and pregnancy status and provision of referring physician contact information improved significantly. The quality of the clinical notes was stable, with good initial scores. Part III testing showed overall improvement, with the mean score increasing from 61% to 76% (P radiology services, and the experience typically afforded to interns does not address this lack of knowledge. The ROM program was a successful intervention that resulted in statistically significant improvements in the quality of radiologic examination orders, particularly with regard to logistic and radiation safety issues.
Assessment of risk in radiology using malpractice RVU
International Nuclear Information System (INIS)
Cristofaro, Massimo; Bellandi, Giuseppe; Squarcione, Salvatore; Petecchia, Antonella; Mammarella, Assunta; Bibbolino, Corrado
2007-01-01
Introduction: Analysis on the causes and remedies needed to reduce the incidence of malpractice has been under continual studies, although limited data is available regarding quantitative evaluation of the risk. Objectives: To determine radiological risk in a preventive and quantitative manner and verify if the malpractice relative value units (MP-RVU) are a good indicator of associated risk factors. Materials and methods: Radiological examinations executed by our Radiology Department in 2000-2004 have been codified according to nomenclature HCPCS (Healthcare Common Procedure Coding System) used by United States of America Centers for Medicare and Medicaid Services (CMS). For every examination was calculated the annual weight of malpractice. The data has been groupped in macroaggregates by methodology. The ratio MP-RVU/no. examinations has been considered as an index of insurance risk (MP index) Results: A total of 133,005 examinations were performed, which produced 25,252 MP-RVU points, the total mp index was 0.193. Traditional radiology represents 38% of the examinations, accounting for 8% of MP-RVU with a MP index = 0.039. Ultrasound represents 35% of the examinations, accounting for 23% of MP-RVU with a MP index = 0.125. CT represents 13% of the examinations, accounting for 28% of MP-RVU with a MP index = 0.434. MR represents 11% of the examinations, accounting for 39% of MP-RVU with a MP index = 0.667. Conclusions: Malpractice relative value units (MP-RVU) are indicative of the risk considered globally and when subgrouped. MP index correlates this risk with number of exams carried out divided by methodology. This model providing quantitative data for projects concerning risk management and in allowing the correlation between data obtained in different departments
Assessment of risk in radiology using malpractice RVU
Energy Technology Data Exchange (ETDEWEB)
Cristofaro, Massimo [U.O. di Diagnostica per Immagini, Istituto Nazionale per le Malattie Infettive IRCCS, L. Spallanzani Via Portuense, 292, 00149 Rome (Italy)]. E-mail: mcristofar@srm.org; Bellandi, Giuseppe [Servizio di Radiologia ASL 3 Ospedale di Pescia, Via Battisti 2, 51017 Pescia (PT) (Italy)]. E-mail: g.bellandi@mail.vdn.usl3.toscana.it; Squarcione, Salvatore [Direzione Sanitaria Istituto Istituto Nazionale per le Malattie Infettive IRCCS, L. Spallanzani, Via Portuense 292, 00149 Rome (Italy)]. E-mail: squarcione@inmi.it; Petecchia, Antonella [Direzione Sanitaria Istituto Istituto Nazionale per le Malattie Infettive IRCCS, L. Spallanzani, Via Portuense 292, 00149 Rome (Italy)]. E-mail: petecchia@inmi.it; Mammarella, Assunta [Direzione Sanitaria Istituto Istituto Nazionale per le Malattie Infettive IRCCS, L. Spallanzani, Via Portuense 292, 00149 Rome (Italy)]. E-mail: mammarella@inmi.it; Bibbolino, Corrado [U.O. di Diagnostica per Immagini, Istituto Nazionale per le Malattie Infettive IRCCS, L. Spallanzani Via Portuense, 292, 00149 Rome (Italy)]. E-mail: bibbolino@inmi.it
2007-02-15
Introduction: Analysis on the causes and remedies needed to reduce the incidence of malpractice has been under continual studies, although limited data is available regarding quantitative evaluation of the risk. Objectives: To determine radiological risk in a preventive and quantitative manner and verify if the malpractice relative value units (MP-RVU) are a good indicator of associated risk factors. Materials and methods: Radiological examinations executed by our Radiology Department in 2000-2004 have been codified according to nomenclature HCPCS (Healthcare Common Procedure Coding System) used by United States of America Centers for Medicare and Medicaid Services (CMS). For every examination was calculated the annual weight of malpractice. The data has been groupped in macroaggregates by methodology. The ratio MP-RVU/no. examinations has been considered as an index of insurance risk (MP index) Results: A total of 133,005 examinations were performed, which produced 25,252 MP-RVU points, the total mp index was 0.193. Traditional radiology represents 38% of the examinations, accounting for 8% of MP-RVU with a MP index = 0.039. Ultrasound represents 35% of the examinations, accounting for 23% of MP-RVU with a MP index = 0.125. CT represents 13% of the examinations, accounting for 28% of MP-RVU with a MP index = 0.434. MR represents 11% of the examinations, accounting for 39% of MP-RVU with a MP index = 0.667. Conclusions: Malpractice relative value units (MP-RVU) are indicative of the risk considered globally and when subgrouped. MP index correlates this risk with number of exams carried out divided by methodology. This model providing quantitative data for projects concerning risk management and in allowing the correlation between data obtained in different departments.
International Nuclear Information System (INIS)
Foley, R.D.; Johnson, C.A.
1994-02-01
The property at 90 Avenue C, Lodi, New Jersey is one of the vicinity properties of the former Maywood Chemical Works, Maywood, New Jersey designated for remedial action by the US Department of Energy (DOE). In July 1991, Bechtel National, Inc. performed a partial remedial action on this property. At the request of DOE, a team from Oak Ridge National Laboratory conducted an independent radiological verification survey in July, 1991 at this site. The purpose of the verification survey was to ensure the effectiveness of remedial actions performed within FUSRAP and to confirm the site's compliance with DOE guidelines. The radiological survey included surface gamma scans indoors and outdoors, ground-level beta-gamma measurements, and systematic and biased soil and material sampling. Results of the verification survey demonstrated that all radiological measurements on the portions of the property that had been remediated were within DOE guidelines. However, there still remains a portion of the property to be remediated that is not covered by this verification survey
Radiology curriculum for undergraduate medical studies—A consensus survey
International Nuclear Information System (INIS)
Mirsadraee, S.; Mankad, K.; McCoubrie, P.; Roberts, T.; Kessel, D.
2012-01-01
Aim: To establish an expert consensus of what, when, and how the teaching of radiology should be incorporated into the core undergraduate medical curriculum. Methods and materials: This Delphi survey consisted of four iterative rounds, with feedback given at the start of each successive round in the form of the results of the previous round. The participants consisted of both radiologists and non-radiologists with significant interest and involvement in radiology and undergraduate/Foundation training. The study addressed the questions of how, where, when, and by whom radiology should be taught. Results: The number of responses in rounds 1–4 was 20, 23, 41, and 25 (25, 22, 31, and 61% response rate, respectively). There was good consensus amongst the responders on the following: radiology teaching must be delivered in conjunction with anatomy and clinical case-based teaching, if possible in the department of radiology on picture archiving and communication system (PACS) workstations, and the teaching should be delivered by a competent and credentialled individual. Case-based assessment was the most agreed method of assessment. The majority of the responders concurred that the curriculum should include general indications for commonly requested radiological investigations, consent and safety issues around radiological tests, and their basic interpretation. Conclusion: The consensus points reached by the present study not only serve as directive principles for developing a more comprehensive radiology curriculum, but also places emphasis on a broader range of knowledge required to promote the best use of a department of radiology by junior doctors in an attempt to improve patient experiences and care.
Diagnostic efficacy of radiological examinations in clefts of the hard palate
International Nuclear Information System (INIS)
Cieslinska-Wilk, G.
1992-01-01
The aim of the work has been: 1) evaluating the efficiency of individual radiological methods in visualizing the bone structure of the hard palate; 2) elaboration of a method for skull examination, by means of which the hard palate region in patients would be best visible; 3) presentation of radiological symptomatology of hard palate clefts; 4) establishing algorithms of diagnostic procedure and determining the type of radiological examination most helpful in planning the treatment of this anomaly. Selected problems from normal anatomy of the hard palate are presented, and the technique of radiological examination in the form of occlusal radiograms, pantomography and computerized tomography (CT) are discussed. Clinical material encompassed the total of 312 patients. A total of 470 radiograms were performed, 150 occlusal ones of hard palate, 200 pantomograms (jointly with the control group) as well as 120 scannings during CT examination. It has been stated the greatest efficiency and effectiveness in planning the treatment are ascribed to computerized tomography, the second place goes to pantomography, on the third position are occlusal radiograms targeted at the region of the cleft. Algorithms have been provided for roentgen-diagnostic procedure in cases of the hard palate clefts, with an emphasis that the very first examination of a child should include the occlusal radiograms targeted at the cleft region and pantomogram; in the course of conservative treatment only pantomogram is proposed to be made, and in case of planned operative procedure - CT examination. For evaluating the calcification of the cleft, the best and with the least irradiation are the intraoral occlusal radiograms, targeted at the region of the cleft, performed 12 months after the operation. (author). 100 refs, 21 figs, 12 tabs
Radiological diagnosis of pulmonary hypertension
International Nuclear Information System (INIS)
Huebsch, P.; Jenny, C.; Schwaighofer, B.; Seidl, G.; Burghuber, O.C.
1987-01-01
In 43 patients with obstructive and restrictive lung disease a catheterisation of the right heart with measurement of pulmonary artery pressure was performed. In a retrospective study several radiological parameters of pulmonary hypertension were evaluated on the chest radiographs of these patients. Considering those parameters on the p.a. and lateral chest radiograph, the diagnosis of pulmonary hypertension in patients with elevated pulmonary artery pressure at rest can be made with great accuracy. When pulmonary artery pressure is elevated only during exercise, the accuracy of radiological diagnosis is much lower. (orig.) [de
Effect of Massed Versus Interleaved Teaching Method on Performance of Students in Radiology.
Rozenshtein, Anna; Pearson, Gregory D N; Yan, Sherry X; Liu, Andrew Z; Toy, Dennis
2016-08-01
Radiology instruction is based on the principle that grouped (or massed) repetition of an intellectual activity leads to expertise. The aim of this study was to test the hypothesis that the spaced (or interleaved) method of teaching chest x-ray interpretation is more effective than the massed method. After institutional review board approval was obtained, 40 first- and second-year medical students were randomized into two groups matched by age, gender, and education experience. Both groups saw six examples of 12 common chest radiographic patterns, one grouped, the other scrambled randomly without repeating strings. After a distraction, participants took a multiple-choice test consisting of two cases in each radiographic pattern, one previously shown, one new. Results were analyzed using two-tailed Student's t test of proportion. Comparing interleaved and massed groups, the average overall score was 57% versus 43% (P = .03), the recollection score was 61% versus 47% (P = .03), and the induction score was 53% versus 40% (P = 0.10), respectively. Comparing second- and first-year students, average scores were 67% and 39%, respectively (P method of instruction leads to better results than the massed method across all levels of education. A higher level of medical education improves performance independent of method of instruction. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Evaluation criteria for emergency response plans in radiological transportation
International Nuclear Information System (INIS)
Lindell, M.K.; Perry, R.W.
1980-01-01
This paper identifies a set of general criteria which can be used as guides for evaluating emergency response plans prepared in connection with the transportation of radiological materials. The development of criteria takes the form of examining the meaning and role of emergency plans in general, reviewing the process as it is used in connection with natural disasters and other nonnuclear disasters, and explicitly considering unique aspects of the radiological transportation setting. Eight areas of critical importance for such response plans are isolated: notification procedures; accident assessment; public information; protection of the public at risk; other protective responses; radiological exposure control; responsibility for planning and operations; and emergency response training and exercises. (Auth.)
Data analysis for radiological characterisation: Geostatistical and statistical complementarity
International Nuclear Information System (INIS)
Desnoyers, Yvon; Dubot, Didier
2012-01-01
Radiological characterisation may cover a large range of evaluation objectives during a decommissioning and dismantling (D and D) project: removal of doubt, delineation of contaminated materials, monitoring of the decontamination work and final survey. At each stage, collecting relevant data to be able to draw the conclusions needed is quite a big challenge. In particular two radiological characterisation stages require an advanced sampling process and data analysis, namely the initial categorization and optimisation of the materials to be removed and the final survey to demonstrate compliance with clearance levels. On the one hand the latter is widely used and well developed in national guides and norms, using random sampling designs and statistical data analysis. On the other hand a more complex evaluation methodology has to be implemented for the initial radiological characterisation, both for sampling design and for data analysis. The geostatistical framework is an efficient way to satisfy the radiological characterisation requirements providing a sound decision-making approach for the decommissioning and dismantling of nuclear premises. The relevance of the geostatistical methodology relies on the presence of a spatial continuity for radiological contamination. Thus geo-statistics provides reliable methods for activity estimation, uncertainty quantification and risk analysis, leading to a sound classification of radiological waste (surfaces and volumes). This way, the radiological characterization of contaminated premises can be divided into three steps. First, the most exhaustive facility analysis provides historical and qualitative information. Then, a systematic (exhaustive or not) surface survey of the contamination is implemented on a regular grid. Finally, in order to assess activity levels and contamination depths, destructive samples are collected at several locations within the premises (based on the surface survey results) and analysed. Combined with
Radiological/biological/aerosol removal system
Haslam, Jeffery J
2015-03-17
An air filter replacement system for existing buildings, vehicles, arenas, and other enclosed airspaces includes a replacement air filter for replacing a standard air filter. The replacement air filter has dimensions and air flow specifications that allow it to replace the standard air filter. The replacement air filter includes a filter material that removes radiological or biological or aerosol particles.
International Nuclear Information System (INIS)
Larsson, Arne; Weber, Inge; Emptage, Matthew; )
2016-01-01
Full text of publication follows: The Task Group on Radiological Characterisation and Decommissioning within the Nuclear Energy Agency (NEA) Working Party on Decommissioning was established to identify and present Best Practice in radiological characterisation at different stages of decommissioning as well as areas that could or should be developed further by international cooperation and coordination. The first phase of the project was focusing on general aspects of strategies for radiological characterisation in decommissioning of nuclear facilities. The second phase of the project focus on strategies for optimising radiological characterisation in a waste and materials end-state perspective, building on previous task group findings. One of the activities within the second phase has been to conduct a survey with the main objective to identify Best Practice. The survey was in the form of a questionnaire in two versions, one for regulators and one for owners/implementers. Sections of the questionnaire to gather views on Best Practice: - Initiation of a characterisation program; - Planning and preparation; - Implementation (i.e. conducting the characterisation measurements and samplings); - Data assessment phase (evaluation of the results); - Quality assurance. A section on the national legislation in the regulator version and a case study section in the owner version complement the questionnaire in order to get an overview of the regulatory frameworks and also practical experiences. The extensive questionnaire was distributed to a wide audience of recognised experts throughout the member states. 53 responses were received from in total 12 countries. Most responses were from Europe but also Asia and North America were represented. The preliminary conclusions are: - There is a solid experience in radiological characterisation among regulators as well as owners/implementers; - Responses demonstrates to large extent a common view of regulators and owners
International Nuclear Information System (INIS)
Laurila, J.; Standertskjoeld-Nordenstam, C.G.; Suramo, I.; Tolppanen, E.M.; Tervonen, O.; Korhola, O.; Brommels, M.
2000-01-01
To study the efficacy of continuous quality improvement (CQI) compared to ordinary management in an on-duty radiology department. Because of complaints regarding delivery of on-duty radiological services, an improvement was initiated simultaneously at two hospitals, at the HUCH (Helsinki University Central Hospital) utilising the CQI-method, and at the OUH (Oulu University Hospital) with a traditional management process. For the CQI project, a team was formed to evaluate the process with flow-charts, cause and effect diagrams, Pareto analysis and control charts. Interventions to improve the process were based on the results of these analyses. The team at the HUCH implemented the following changes: A radiologist was added to the evening shift between 15:00 - 22:00 and a radiographer was moved from the morning shift to 15:00 - 22:00. A clear improvement was achieved in the turn-around time, but in the follow-up some of the gains were lost. Only minimal changes were achieved at the OUH, where the intervention was based on traditional management processes. CQI was an effective method for improving the quality of performance of a radiology department compared with ordinary management methods, but some of this improvement may be subsequently lost without a continuous measurement system
Radiation monitoring systems and methodologies for radiological impact assessment
International Nuclear Information System (INIS)
Chaudhury, Probal
2016-01-01
Radioactive sources of various strengths are used in large number of applications in industry, healthcare, agriculture and research. Though all the sources are transported and used under regulatory control, there is always a possibility of some of the sources getting into the hands of committed antisocial non state actors. In addition to this, there is a possible threat of radioactive material being illegally brought into a country. These gives rise to an increase in the global radiological threat and security experts world over are concerned about the possibility of malicious use of radiation in the public domain. Radiation detection systems are installed at various entry and exit ports of some of the countries to detect illicit trafficking of radioactive materials. IAEA has recommended that all States should have a national response plan for nuclear security events to provide for an appropriate and coordinated response. Considering the requirement of radiological emergency preparedness, various radiation monitoring systems and methodologies have been developed. A few aerial radiation monitoring systems developed at Bhabha Atomic Research Centre (BARC) for radiological impact assessment are described here
Thermoluminescent dosimetry in veterinary diagnostic radiology
International Nuclear Information System (INIS)
Hernández-Ruiz, L.; Jimenez-Flores, Y.; Rivera-Montalvo, T.; Arias-Cisneros, L.; Méndez-Aguilar, R.E.; Uribe-Izquierdo, P.
2012-01-01
This paper presents the results of Environmental and Personnel Dosimetry made in a radiology area of a veterinary hospital. Dosimetry was realized using thermoluminescent (TL) materials. Environmental Dosimetry results show that areas closer to the X-ray equipment are safe. Personnel Dosimetry shows important measurements of daily workday in some persons near to the limit established by ICRP. TL results of radiation measurement suggest TLDs are good candidates as a dosimeter to radiation dosimetry in veterinary radiology. - Highlights: ► Personnel dosimetry in laboratory veterinary diagnostic was determined. ► Student workplaces are safe against radiation. ► Efficiency value of apron lead was determined. ► X-ray beams distribution into veterinarian laboratory was measured.
Radiation Protection in Paediatric Radiology
International Nuclear Information System (INIS)
2012-01-01
Over the past decade and a half, special issues have arisen regarding the protection of children undergoing radiological examinations. These issues have come to the consciousness of a gradually widening group of concerned professionals and the public, largely because of the natural instinct to protect children from unnecessary harm. Some tissues in children are more sensitive to radiation and children have a long life expectancy, during which significant pathology can emerge. The instinct to protect children has received further impetus from the level of professional and public concern articulated in the wake of media responses to certain publications in the professional literature. Many institutions have highlighted the need to pay particular attention to the special problems of protecting paediatric patients. The International Commission on Radiological Protection has noted it and the IAEA's General Safety Requirements publication, Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards (BSS), requires it. This need has been endorsed implicitly in the advisory material on paediatric computed tomography scanning issued by bodies such as the US Food and Drug Administration and the National Cancer Institute in the United States of America, as well as by many initiatives taken by other national and regional radiological societies and professional bodies. A major part of patient exposure, in general, and paediatric exposure, in particular, now arises from practices that barely existed two decades ago. For practitioners and regulators, it is evident that this innovation has been driven both by the imaging industry and by an ever increasing array of new applications generated and validated in the clinical environment. Regulation, industrial standardization, safety procedures and advice on best practice lag (inevitably) behind industrial and clinical innovations. This Safety Report is designed to consolidate and provide timely advice on
Energy Technology Data Exchange (ETDEWEB)
Mostert, A.K. [Isala Clinics, Location Weezenlanden, Dept. of Orthopaedic Surgery, Zwolle (Netherlands); Dijkstra, P.F. [Jan van Breemen Inst., Dept. of Radiology, Amsterdam (Netherlands); Horn, J.R. van [Univ. Hospital Groningen, Dept. of Orthopaedic Surgery, Groningen (Netherlands); Jansen, B.R.H. [Reinier de Graaf Hospital, Dept. of Orthopaedic Surgery, Delft (Netherlands); Heutink, P. [Erasmus MCRotterdam, Dept. of Clinical Genetics, Rotterdam (Netherlands); Lindhout, D. [Univ. Medical Centre Utrecht, Dept. of Medical Genetics, Utrecht (Netherlands)
2002-07-01
Aim: To prove that bilateral hereditary micro-epiphyseal dysplasia (BHMED), first described by Elsbach in 1959, is a distinct disorder radiologically as well as clinically, compared with multiple epiphyseal dysplasia (MED). Material and Methods: We used the data of the revised pedigree with 84 family members, performed a medical history, physical examination and made a radiological evaluation for defining a clinical and radiological phenotype of BHMED family members. We used blood samples for genetic analysis. Results: Although there is a clear clinical picture of the dysplasia, the radiological signs are more reliable for making the diagnosis. Especially the typical deformity of the hip and knee joint are diagnostic for BHMED. By linkage analysis we excluded linkage with the three known MED-loci (EDM1, EDM2 and EDM3). Conclusion: BHMED is indeed an entity that is distinct from common multiple epiphyseal dysplasia (MED), clinically, as well as radiologically and genetically. (orig.) [German] Ziel: Es sollte dargelegt werden, dass sich eine vererbliche, laterale Mikro-Epiphysendysplasie (BHMED), Erstbeschreibung durch Elsbach 1959, klinisch, radiologisch und genetisch von einer mutiplen Epiphysendysplasie (MED) unterscheidet. Material und Methode: Anhand der Daten eines ueberarbeiteten Stammbaumes mit 84 Familienmitgliedern wurde der medizinische Werdegang rekonstruiert. Es erfolgte eine physische Untersuchung der Familienmitglieder. Schliesslich wurde eine radiologische Auswertung durchgefuehrt, um einen klinischen und radiologischen Phaenotyp der von BHMED betroffenen Familienmitglieder zu definieren. Fuer eine genetische Analyse wurden Blutproben entnommen. Ergebnisse: Obwohl es ein deutliches klinisches Bild einer Dysplasie gibt, sind die radiologischen Kennzeichen fuer die Diagnose zuverlaessiger. Insbesondere die typische Deformation der Huefte und des Kniegelenks ist diagnostisch fuer BHMED. Durch Linkage-Analyse konnte eine Verbindung zu den drei bekannten
Assessment of Safety Parameters for Radiological Explosion Based on Gaussian Dispersion Model
Energy Technology Data Exchange (ETDEWEB)
Pandey, Alok [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Yu, Hyungjoon; Kim, Hong Suk [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)
2014-10-15
These sources if used with explosive (called RDD - radiological dispersion device), can cause dispersion of radioactive material resulting in public exposure and contamination of the environment. Radiological explosion devices are not weapons for the mass destruction like atom bombs, but can cause the death of few persons and contamination of large areas. The reduction of the threat of radiological weapon attack by terrorist groups causing dispersion of radioactive material is one of the priority tasks of the IAEA Nuclear Safety and Security Program.Emergency preparedness is an essential part for reducing and mitigating radiological weapon threat. Preliminary assessment of dispersion study followed by radiological explosion and its quantitative effect will be helpful for the emergency preparedness team for an early response. The effect of the radiological dispersion depends on various factors like radioisotope, its activity, physical form, amount of explosive used and meteorological factors at the time of an explosion. This study aim to determine the area affected by the radiological explosion as pre assessment to provide feedback to emergency management teams for handling and mitigation the situation after an explosion. Most practical scenarios of radiological explosion are considered with conservative approach for the assessment of the area under a threat for emergency handling and management purpose. Radioisotopes under weak security controls can be used for a radiological explosion to create terror and socioeconomic threat for the public. Prior assessment of radiological threats is helpful for emergency management teams to take prompt decision about evacuation of the affected area and other emergency handling actions. Comparable activities of Co-60 source used in radiotherapy and Sr-90 source of disused and orphaned RTGs with two different quantities of TNT were used for the scenario development of radiological explosion. In the Basic Safety Standard (BSS
Assessment of Safety Parameters for Radiological Explosion Based on Gaussian Dispersion Model
International Nuclear Information System (INIS)
Pandey, Alok; Yu, Hyungjoon; Kim, Hong Suk
2014-01-01
These sources if used with explosive (called RDD - radiological dispersion device), can cause dispersion of radioactive material resulting in public exposure and contamination of the environment. Radiological explosion devices are not weapons for the mass destruction like atom bombs, but can cause the death of few persons and contamination of large areas. The reduction of the threat of radiological weapon attack by terrorist groups causing dispersion of radioactive material is one of the priority tasks of the IAEA Nuclear Safety and Security Program.Emergency preparedness is an essential part for reducing and mitigating radiological weapon threat. Preliminary assessment of dispersion study followed by radiological explosion and its quantitative effect will be helpful for the emergency preparedness team for an early response. The effect of the radiological dispersion depends on various factors like radioisotope, its activity, physical form, amount of explosive used and meteorological factors at the time of an explosion. This study aim to determine the area affected by the radiological explosion as pre assessment to provide feedback to emergency management teams for handling and mitigation the situation after an explosion. Most practical scenarios of radiological explosion are considered with conservative approach for the assessment of the area under a threat for emergency handling and management purpose. Radioisotopes under weak security controls can be used for a radiological explosion to create terror and socioeconomic threat for the public. Prior assessment of radiological threats is helpful for emergency management teams to take prompt decision about evacuation of the affected area and other emergency handling actions. Comparable activities of Co-60 source used in radiotherapy and Sr-90 source of disused and orphaned RTGs with two different quantities of TNT were used for the scenario development of radiological explosion. In the Basic Safety Standard (BSS
International Nuclear Information System (INIS)
Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Lu, Guang Ming; Schoepf, U.J.; Xu, Jiaqian; Li, Enzhong
2017-01-01
To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Zhang, Long Jiang; Wang, Yun Fei; Yang, Zhen Lu; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Xu, Jiaqian [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Li, Enzhong [National Natural Science Foundation of China, Department of Medical Science, Beijing (China)
2017-10-15
To evaluate the features and trends of Radiology research in Mainland China through bibliometric analysis of the original articles published in Radiology and European Radiology (ER) between 2006 and 2015. We reviewed the original articles published in Radiology and ER between 2006 and 2015. The following information was abstracted: imaging subspecialty, imaging technique(s) used, research type, sample size, study design, statistical analysis, study results, funding declarations, international collaborations, number of authors, department and province of the first author. All variables were examined longitudinally over time. Radiology research in Mainland China saw a substantial increase in original research articles published, especially in the last 5 years (P < 0.001). Within Mainland China's Radiology research, neuroradiology, vascular/interventional Radiology, and abdominal Radiology were the most productive fields; MR imaging was the most used modality, and a distinct geographic provenience was observed for articles published in Radiology and ER. Radiology research in Mainland China has seen substantial growth in the past 5 years with neuroradiology, vascular/interventional Radiology, and abdominal Radiology as the most productive fields. MR imaging is the most used modality. Article provenience shows a distinct geographical pattern. (orig.)
Estimation of Radiological Terrorism Risk by Administrative Districts
Energy Technology Data Exchange (ETDEWEB)
Kim, Suk Hoon; Kim, Ju Youl [Seoul National Univ., Seoul (Korea, Republic of); Yoo, Ho Sik [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)
2008-10-15
Since the 9/11 attack in USA, the threat of terrorism across the world has dramatically increased. Accordingly, estimating terrorism risk has become an essential part of catastrophe risk strategies throughout the world. There are many forms of terrorism. Recently, the prospect of the radiological terrorist attack using the radioactive material is considered as one of the most serious threats. The aim of this paper is to assess the radiological terrorism risk by administrative districts based on the parameters that imply threat, vulnerability, and consequences of terrorist attacks.
TENORM radiological survey of Utica and Marcellus Shale
International Nuclear Information System (INIS)
Ying, Leong; O’Connor, Frank
2013-01-01
Comprehensive on-site radiological survey of processed sludge drilled materials extracted from the oil and gas production activities in the Utica and Marcellus Shale in Ohio has been conducted with a shielded isotopic identifier incorporating an advanced patented algorithmic processor to measure low-activity levels in compliance with environmental standards. - highlights: • First on-site radiological survey of processed shale sludge from oil and gas fields. • Mobile spectroscopic radiation inspection system with shielding for low-activity measurements. • Quantification of Ra-226 and Ra-228 radionuclides contamination in soil samples
Estimation of Radiological Terrorism Risk by Administrative Districts
International Nuclear Information System (INIS)
Kim, Suk Hoon; Kim, Ju Youl; Yoo, Ho Sik
2008-01-01
Since the 9/11 attack in USA, the threat of terrorism across the world has dramatically increased. Accordingly, estimating terrorism risk has become an essential part of catastrophe risk strategies throughout the world. There are many forms of terrorism. Recently, the prospect of the radiological terrorist attack using the radioactive material is considered as one of the most serious threats. The aim of this paper is to assess the radiological terrorism risk by administrative districts based on the parameters that imply threat, vulnerability, and consequences of terrorist attacks
International Nuclear Information System (INIS)
Buecker, A.; Gross-Fengels, W.; Haage, P.; Huppert, P.; Landwehr, P.; Loose, R.; Reimer, P.; Tacke, J.; Vorwerk, D.; Fischer, J.
2012-01-01
The topics covered in the qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins are the following: Practical qualification: aorta iliac vessels and vessels in the upper and lower extremities, kidney and visceral arteries, head and neck arteries, dialysis shunts, veins and pulmonary arteries, aorta aneurysms and peripheral artery aneurysms. Knowledge acquisition concerning radiation protection: legal fundamentals, education and training, knowledge actualization and quality control, definition of the user and the procedure, competence preservation.
Current trends in gamma radiation detection for radiological emergency response
Mukhopadhyay, Sanjoy; Guss, Paul; Maurer, Richard
2011-09-01
Passive and active detection of gamma rays from shielded radioactive materials, including special nuclear materials, is an important task for any radiological emergency response organization. This article reports on the current trends and status of gamma radiation detection objectives and measurement techniques as applied to nonproliferation and radiological emergencies. In recent years, since the establishment of the Domestic Nuclear Detection Office by the Department of Homeland Security, a tremendous amount of progress has been made in detection materials (scintillators, semiconductors), imaging techniques (Compton imaging, use of active masking and hybrid imaging), data acquisition systems with digital signal processing, field programmable gate arrays and embedded isotopic analysis software (viz. gamma detector response and analysis software [GADRAS]1), fast template matching, and data fusion (merging radiological data with geo-referenced maps, digital imagery to provide better situational awareness). In this stride to progress, a significant amount of inter-disciplinary research and development has taken place-techniques and spin-offs from medical science (such as x-ray radiography and tomography), materials engineering (systematic planned studies on scintillators to optimize several qualities of a good scintillator, nanoparticle applications, quantum dots, and photonic crystals, just to name a few). No trend analysis of radiation detection systems would be complete without mentioning the unprecedented strategic position taken by the National Nuclear Security Administration (NNSA) to deter, detect, and interdict illicit trafficking in nuclear and other radioactive materials across international borders and through the global maritime transportation-the so-called second line of defense.
The radiological monitoring protocol for metallic products and cleared scrap management
International Nuclear Information System (INIS)
Gil Lopez, E.
2003-01-01
Event though the use of nuclear and radiological techniques is subject to strict controls in most countries, the presence of radioactive material in batches of metallic scrap has been detected with relative frequency in the last few years. This circumstance has motivated the implementation of a series of national and international initiatives aimed at detecting and preventing this type of events, whether they be intentional or involuntary. The Spanish iron and steel industry is one of the country's most important industrial sectors, and to a great extent it depends on the importation of a very significant amount of metallic scrap that it uses as raw material. Experience has shown that countries that import large amounts of scrap, apart from supporting the mentioned international initiatives, should complement them with other national initiatives to reduce the risks resulting from the presence of radioactive material in scrap. In this context, the Spanish authorities, together with trade unions and entrepreneurial associations in the metal reclamations and smelting sectors and ENRESA, have signed a voluntary Protocol that defines and implements a national radiological monitoring and control system for scrap materials and their byproducts. The Protocol defines the obligations and rights of the signatories, and it describes the monitoring and control system and its legal bases, the operation of both specific and other general-purpose radiological monitoring equipment that existed prior to this initiative, the development of radiological training and dissemination plans for professionals in the metal reclamation and smelting sectors, the establishment of effective systems for the safe management of any radioactive materials detected, and the general improvement of the national response system in the event of radiological emergencies. Since the Protocol took effect in November 1999, more than 100 enterprises from the metallurgical (steel, copper, lead and aluminum
Radiological Situation at the Bomb Test Sites
International Nuclear Information System (INIS)
Valkovic, V.
1998-01-01
An overview of radiological situation at the selected bomb test sites is presented. The report is based on the reports and measurements performed by IAEA while the author was a head of its Physics-Chemistry-Instrumentation Laboratory. Radiological conditions at Bikini Atoll (USA testing ground), Mururoa and Fangataufa Atolls (French testing ground) and Semipalatinsk (SSSR testing ground) have been discussed in some details. (author)
Energy Technology Data Exchange (ETDEWEB)
Butragueno, J. L.; Villota, C.; Gutierrez, C.; Rodriguez, A.
2004-07-01
The objective of Radiological Protection is to gurantee that neither people, be they workers or members of the public, or the environment are exposed to radiological risks considered by society to be unacceptable. Among the various resources available to meet this objective is Research and Development (R and D), which is carried out in three areas: I. Radiological protection of persons: (a) knowledge of the biological effects of radiations, in order to determine the relationship that exists between radiation exposure dose and its effects on health; (b) the development of new personal dosimetry techniques in order to adapt to new situations, instrumental techniques and information managmenet technologies allowing for better assessment of exposure dose; and (c) development of the principle of radiological protection optimisation (ALARA), which has been set up internationally as the fundamental principle on which radiological protection interventions are based. II. Assessment of environmental radiological impact, the objective of which is to assess the nature and magnitude of situations of exposure to ionising radiations as a result of the controlled or uncontrolled release of radioactive material to the environment, and III.Reduction of the radiological impact of radioactive wastes, the objective of which is to develop radioactive material and waste management techniques suitable for each situation, in order to reduce the risks assocaited with their definitive managmenet or thier release to the environment. Briefly desribed below are the strategic lines of R and D of the CSN, the Electricity Industry, Ciemat and Enresa in the aforementioned areas. (Author)
Application of historical Y-12 default radiological activity values to legacy waste
International Nuclear Information System (INIS)
Coleman, G.
2009-01-01
In June of 2003, Bechtel Jacobs Company LLC tasked Pacific Western Technologies (PWT) to perform a comprehensive audit of the Facility Acceptance Testing/ Container Analysis Tool (FAT-CAT), which is currently administered, by Bechtel Jacobs Company LLC... During this audit, a finding was issued on the subject of assigning historic Y-12 default radiological activity values to radiological containers, having no radiological data. Analysis of default radiological values versus known real radiological values showed the default values to be conservative as a place-holder for containers with no known radiological values. (authors)
Andriole, Katherine P; Morin, Richard L; Arenson, Ronald L; Carrino, John A; Erickson, Bradley J; Horii, Steven C; Piraino, David W; Reiner, Bruce I; Seibert, J Anthony; Siegel, Eliot
2004-12-01
The Society for Computer Applications in Radiology (SCAR) Transforming the Radiological Interpretation Process (TRIP) Initiative aims to spearhead research, education, and discovery of innovative solutions to address the problem of information and image data overload. The initiative will foster interdisciplinary research on technological, environmental and human factors to better manage and exploit the massive amounts of data. TRIP will focus on the following basic objectives: improving the efficiency of interpretation of large data sets, improving the timeliness and effectiveness of communication, and decreasing medical errors. The ultimate goal of the initiative is to improve the quality and safety of patient care. Interdisciplinary research into several broad areas will be necessary to make progress in managing the ever-increasing volume of data. The six concepts involved are human perception, image processing and computer-aided detection (CAD), visualization, navigation and usability, databases and integration, and evaluation and validation of methods and performance. The result of this transformation will affect several key processes in radiology, including image interpretation; communication of imaging results; workflow and efficiency within the health care enterprise; diagnostic accuracy and a reduction in medical errors; and, ultimately, the overall quality of care.
Evaluation of PC-based diagnostic radiology workstations
International Nuclear Information System (INIS)
Pollack, T.; Brueggenwerth, G.; Kaulfuss, K.; Niederlag, W.
2000-01-01
Material and Methods: During February 1999 and September 1999 medical users at the hospital Dresden-Friedrichstadt Germany had tested 7 types of radiology diagnostic workstations. Two types of test methods were used: In test type 1 ergonomic and handling functions were evaluated impartial according to 78 selected user requirements. In test type 2 radiologists and radiographers (3+4) performed 23 work flow steps with a subjectively evaluation. Results: By using a progressive rating no product could fully meet the user requirements. As a result of the summary evaluation for test 1 and test 2 the following compliance rating was calculated for the different products: Rad Works (66%), Magic View (63%), ID-Report (58%), Impax 3000 (53%), Medical Workstation (52%), Pathspeed (46%) and Autorad (39%). (orig.) [de
Report writing in skeletal radiology
International Nuclear Information System (INIS)
Rowe, L.J.; Yochum, T.R.
1987-01-01
The formulation of reports in clinical practice is a standard method of documentation of a patient's history, examination findings, therapeutic regime, and prognosis, as well as other important features. In the practice of producing and interpreting diagnostic radiographs, report writing also serves a number of important roles, which include providing an accurate means of recording findings in instances of 1) medicolegal circumstances; 2) a standard for comparison with previous or later examinations; 3) a permanent record if the radiographs are lost or not immediately available for perusal; 4) communication with other practitioners and health professionals; and 5) expediating the treatment regime by providing a resume of important indications and contraindictions for therapy. In the radiological literature there is a distinct lack of material on report writing and very little as to what would be considered a standard style. Consequently, radiological reporting has increasingly become a subjective, personalized procedure, with each individual modifying the report according to previous training, experience, and needs. It is the purpose of this chapter to provide basic guidelines on the mechanisms of formulating adequate standardized reports in radiological examinations of the skeletal system
International Nuclear Information System (INIS)
Wade, C.D.
1997-06-01
This document describes the implementation of the Laser-Assisted Ranging and Data System (LARADS) as it applies to performing radiological surveys on facility exterior and interior surfaces. The LARADS enables the system operator to document scanning measurements, stationary radiological measurements, and sample locations of surfaces, with the radiological readings and exact coordinates (<2 cm [0.8 in.] precision) automatically logged in real-time. After the survey is completed, the information is downloaded to a geographical information system, and the radiological information is overlaid on a digital picture of the survey area or may be generated as a computer- aided drafted drawing. The final product is a track map or contour of the survey area that clearly shows the area covered by the detector and the locations of elevated readings. The exact reproducibility of data facilitates locating hot spots for remediation and provides for objective review by regulators and verifiers
Cost analysis of radiological interventional procedures and reimbursement within a clinic
International Nuclear Information System (INIS)
Strotzer, M.; Voelk, M.; Lenhart, M.; Fruend, R.; Feuerbach, S.
2002-01-01
Purpose: Analysis of costs for vascular radiological interventions on a per patient basis and comparison with reimbursement based on GOAe(Gebuehrenordnung fuer Aerzte) and DKG-NT (Deutsche Krankenhausgesellschaft-Nebenkostentarif). Material and Methods: The ten procedures most frequently performed within 12 months were evaluated. Personnel costs were derived from precise costs per hour and estimated procedure time for each intervention. Costs for medical devices were included. Reimbursement based on GOAewas calculated using the official conversion factor of 0.114 DM for each specific relative value unit and a multiplication factor of 1.0. The corresponding conversion factor for DKG-NT, determined by the DKG, was 0.168 DM. Results: A total of 832 interventional procedures were included. Marked differences between calculated costs and reimbursement rates were found. Regarding the ten most frequently performed procedures, there was a deficit of 1.06 million DM according GOAedata (factor 1.0) and 0.787 million DM according DKG-NT. The percentage of reimbursement was only 34.2 (GOAe; factor 1.0) and 51.3 (DKG-NT), respectively. Conclusion: Reimbursement of radiological interventional procedures based on GOAeand DKG-NT data is of limited value for economic controlling purposes within a hospital. (orig.) [de
Nagy, Paul G; Warnock, Max J; Daly, Mark; Toland, Christopher; Meenan, Christopher D; Mezrich, Reuben S
2009-11-01
Radiology departments today are faced with many challenges to improve operational efficiency, performance, and quality. Many organizations rely on antiquated, paper-based methods to review their historical performance and understand their operations. With increased workloads, geographically dispersed image acquisition and reading sites, and rapidly changing technologies, this approach is increasingly untenable. A Web-based dashboard was constructed to automate the extraction, processing, and display of indicators and thereby provide useful and current data for twice-monthly departmental operational meetings. The feasibility of extracting specific metrics from clinical information systems was evaluated as part of a longer-term effort to build a radiology business intelligence architecture. Operational data were extracted from clinical information systems and stored in a centralized data warehouse. Higher-level analytics were performed on the centralized data, a process that generated indicators in a dynamic Web-based graphical environment that proved valuable in discussion and root cause analysis. Results aggregated over a 24-month period since implementation suggest that this operational business intelligence reporting system has provided significant data for driving more effective management decisions to improve productivity, performance, and quality of service in the department.
International Nuclear Information System (INIS)
Mckinney, S.M.
1997-01-01
This report provides a summary of the radiological surveys performed in support of near-facility environmental monitoring at the Hanford Site. The First Quarter 1997 survey results and the status of actions required are summarized below: (1) All of the routine environmental radiological surveys scheduled during January, February, and March 1997, were performed as planned. (2) One hundred four environmental radiological surveys were performed during the first quarter 1997, twenty-nine at the active waste sites and seventy-five at the inactive waste sites. Contamination above background levels was found at eight of the active waste sites and seven of the inactive waste sites. Contamination levels as high as >1,000,000 disintegrations per minute (dpm) were reported. Of these contaminated surveys twelve were in Underground Radioactive Material (URM) areas and three were in contamination areas. The contamination found within ten of the URM areas was immediately cleaned up and no further action was required. In the remaining five sites the areas were posted and will require decontamination. Radiological Problem Reports (RPR's) were issued and the sites were turned over to the landlord for further action if required. (3) During the first quarter of 1997, 5.6 hectares (13.8 acres) were stabilized and radiologically down posted from Contamination Area (CA)/Soil Contamination (SC) to URM. (4) During the first quarter of 1997, the size of 216-A-25 Gable Mountain Pond was increased from 30.4 to 34.5 hectares (75.0 to 85.2 acres). This increase in size was due to the correction of the original boundary area by using the advanced technology of a global positioning system (GPS). An area, 1.6 hectares (4.0 acres), east of and adjacent to the 241-S/SX/SY tank farm complex was posted as a contamination/soil contamination area. (5) Five open Surveillance Compliance Inspection Reports (SCIRs) had not been resolved
Radiological survey of the former Kellex Research Facility, Jersey City, New Jersey
International Nuclear Information System (INIS)
Berven, B.A.; Dickson, H.W.; Goldsmith, W.A.; Johnson, W.M.; Cottrell, W.D.; Doane, R.W.; Haywood, F.F.; Ryan, M.T.; Shinpaugh, W.H.
1982-02-01
A radiological survey has been conducted at the site of the former Kellex Corporation Research Facility in Jersey City, New Jersey. Kellex played a major role in the Manhattan Project, particularly in the area of engineering research in gaseous diffusion for uranium enrichment. As a result of those operations and subsequent work with radioactive materials, this site was selected for a radiological survey by the Department of Energy (DOE) [then Energy Research and Development Administration (ERDA)] in its program aimed at reviewing and documenting the radiological status of properties associated with early source material contracts. The survaty included measurement of external gamma radiation, beta-gamma surface dose rates, alpha and beta surface contamination, concentrations of selected radionuclides in surface and subsurface soil and water on the site, and background radiation in the northern part of New Jersey. The results of the radiological survey indicate radionuclide concentrations in the soil and water on the former Kellex property are within background levels, with the exception of nine isolated and well-defined areas on the site of the former Kellex Laboratory
International Nuclear Information System (INIS)
Horton, C.N.
1995-01-01
This paper was prepared for the Second Residual Radioactivity and Recycling Criteria Workshop and discusses decommissioning and decontamination activities at the Battelle Columbus Laboratories Decommissioning Project (BCLDP). The BCLDP is a joint effort between the Department of Energy (DOE) and Battelle Columbus Operations to decontaminate fifteen Battelle-owned buildings contaminated with DOE radioactive materials. The privately owned buildings located across the street from The Ohio State University campus became contaminated with natural uranium and thorium during nuclear research activities. BCLDP waste management is supported by an extensive radiological free-release program. Miscellaneous materials and building surfaces have been free-released from the BCLDP. The free-release program has substantially reduced radioactive waste volumes and supported waste minimization. Free release for unrestricted use has challenged regulators and NRC licensees since the development of early surface-release criteria. This paper discusses the surface radiological free-release program incorporated by the BCLDP and the historical development of the surface radiological free-release criteria. Concerns regarding radiological free-release criteria are also presented. (author)
International Nuclear Information System (INIS)
Denham, D.H.; Kathren, R.L.
1989-02-01
Current reductions in ''allowable'' levels of radiation and radioactive materials in the environment and an increased public awareness of naturally occurring radioactive materials have reinforced the need for consistency in evaluating the radiological environment. A key concern is the identification and interpretation of environmental levels of radiation and radioactive materials resulting from nuclear facility operations. If these levels can be detected and their source(s) identified, then corrective actions can be taken to eliminate or greatly reduce the environmental impacts of the facility operations. In this paper we address the lack of definitive guidance necessary to determine incremental levels of significance (or insignificance), and we propose a series of protocols to achieve more consistent collection and interpretation of radiological environmental data. 8 refs
Activity-based cost analysis in catheter-based angiography and interventional radiology
International Nuclear Information System (INIS)
Rautio, R.; Keski-Nisula, L.; Paakkala, T.
2003-01-01
The aim of this study was to analyse the costs of the interventional radiology unit and to identify the cost factors in the different activities of catheter-based angiographies and interventional radiology. In 1999 the number of procedures in the interventional radiological unit at Tampere University Hospital was 2968; 1601 of these were diagnostic angiographies, 526 endovascular and 841 nonvascular interventions. The costs were analysed by using Activity Based Cost (ABC) analysis. The budget of the interventional unit was approximately 1.8 million Euro. Material costs accounted for 67%, personnel costs for 17%, equipment costs for 14% and premises costs for 2% of this. The most expensive products were endografting of aortic aneurysms, with a mean price of 5291 Euro and embolizations of cerebral aneurysms (4472 Euro). Endografts formed 87.3% of the total costs in endografting and Guglielmi detachable coils accounted for 63.3% of the total costs in embolizations. The material costs formed the majority of the costs, especially in the newest and most complicated endovascular treatments. Despite the high cost of angiography equipment, its share of the costs is minor. In our experience ABC system is suitable for analysing costs in interventional radiology. (orig.)
Nevada Test Site Radiological Control Manual, Revision 1
International Nuclear Information System (INIS)
2010-01-01
Management. The NTS has been the primary location for testing nuclear explosives in the continental United States since 1951. The topographical and geological characteristics of the NTS afford some protection to the inhabitants of the surrounding areas from potential radiation exposure as a result of release of radioactivity or contamination from nuclear testing operations. Historically, testing programs at the NTS have included atmospheric testing in the 1950s and early 1960s; underground testing in drilled, vertical holes and horizontal tunnels; earth-cratering experiments; and open air nuclear reactor and engine testing. Current activities include operating low-level radioactive and mixed waste disposal facilities for United States defense-generated waste, assembly and execution of subcritical experiments, assembly/disassembly of special experiments, the storage and use of special nuclear materials, performing criticality experiments, emergency responder training, surface cleanup and site characterization of contaminated land areas, environmental activity by the University system, and nonnuclear test operations, such as controlled spills of hazardous materials at the Hazardous Materials Spill Center. Currently, the major potential for occupational radiation exposure is associated with the burial of low-level radioactive waste and the handling of radioactive sources. Remediation of contaminated land areas may also result in radiological exposures. The Tenant Organizations (TOs) that are responsible for conducting operations, according to this manual, include National Security Technologies, LLC (NSTec), Defense Threat Reduction Agency, Desert Research Institute, Lawrence Livermore National Laboratory, Los Alamos National Laboratory, Navarro Nevada Environmental Services, LLC, Sandia National Laboratories, and WSI. These organizations operate under this manual only when they are performing activities under the purview of NNSA/NSO. To ensure that the appropriate procedures
LENUS (Irish Health Repository)
Marshall, Nina L
2011-09-01
A preliminary audit of orders for computed tomography was performed to evaluate the typical performance of interns ordering radiologic examinations. According to the audit, the interns showed only minimal improvement after 8 months of work experience. The online radiology ordering module (ROM) program included baseline assessment of student performance (part I), online learning with the ROM (part II), and follow-up assessment of performance with simulated ordering with the ROM (part III). A curriculum blueprint determined the content of the ROM program, with an emphasis on practical issues, including provision of logistic information, clinical details, and safety-related information. Appropriate standards were developed by a committee of experts, and detailed scoring systems were devised for assessment. The ROM program was successful in addressing practical issues in a simulated setting. In the part I assessment, the mean score for noting contraindications for contrast media was 24%; this score increased to 59% in the part III assessment (P = .004). Similarly, notification of methicillin-resistant Staphylococcus aureus status and pregnancy status and provision of referring physician contact information improved significantly. The quality of the clinical notes was stable, with good initial scores. Part III testing showed overall improvement, with the mean score increasing from 61% to 76% (P < .0001). In general, medical students lack the core knowledge that is needed for good-quality ordering of radiology services, and the experience typically afforded to interns does not address this lack of knowledge. The ROM program was a successful intervention that resulted in statistically significant improvements in the quality of radiologic examination orders, particularly with regard to logistic and radiation safety issues.
The Oxford unicompartmental knee arthroplasty: a radiological perspective
Energy Technology Data Exchange (ETDEWEB)
Mukherjee, K. [Department of Orthopaedic Radiology, University Hospital of Wales, Cardiff (United Kingdom)], E-mail: kausik.mukherjee@cardiffandvale.wales.nhs.uk; Pandit, H. [North Hampshire Hospital, Basingstoke (United Kingdom); Nuffield Department of Orthopaedic Surgery, University of Oxford, Headington (United Kingdom); Dodd, C.A.F.; Ostlere, S. [Nuffield Orthopaedic Centre, Headington (United Kingdom); Murray, D.W. [Nuffield Department of Orthopaedic Surgery, University of Oxford, Headington (United Kingdom)
2008-10-15
Unicompartmental knee arthroplasty (UKA) is increasingly being performed in both specialist centres as well as district hospitals. The radiologists should be aware of the required preoperative imaging, the normal appearance, and complications of this procedure. Unfortunately, very little is available in the radiology literature. This review aims to provide a radiological perspective to an already widely used procedure.
Clinical, radiological and sonographic correlation in secondary hyperparathyroidism
International Nuclear Information System (INIS)
Giuseppetti, G.M.; Giovannoni, A.; Baldelli, S.; Bordoni, E.
1986-01-01
The results of US study on parathyroid glands, performed in 75 hemodialysed patients are reported. The correlation between morphological feature of the glands, biochemical and radiological pattern of secondary hyperparathyroidism is stressed. The results show a significant link between gland volume and hematic level of PTH: less interesting appears the correlation with radiological pattern of uremic osteodystrophy
Guidelines for selection of radiological protective head covering
International Nuclear Information System (INIS)
Galloway, G.R. Jr.
1995-08-01
The hood is recognized throughout the nuclear industry as the standard radiological protective head covering for use in radioactively contaminated work environments. As of June 15, 1995, hoods were required for all activities performed in contaminated areas at the Y-12 Plant. The use of hoods had historically been limited to those radiological activities with a high potential for personnel contamination. Due to the large size of many posted contaminated areas at the Y-12 Plant, and compounding safety factors, requirements for the use of hoods are being reevaluated. The purpose of the evaluation is to develop technically sound guidelines for the selection of hoods when prescribing radiological protective head covering. This report presents the guidelines for selection of radiological protective hoods
The evolution of radiology information management
International Nuclear Information System (INIS)
Patacsil, L.
2002-01-01
Aim: The use of PACS and the need for images and clinical data is increasing exponentially. This presentation will provide a historical overview of radiology information systems (RIS) and their interaction with hospital information systems (HIS), PACS systems and modalities. Materials and Methods: The various approaches to interfacing and integrating RIS and PACS systems will be described as well as their impact on radiology departmental work-flow and the productivity of radiologists, technologists and other RIS users. Specifically, the image-centric and RIS-centric approaches to PACS will be compared. Results: Instant access to vital clinical information enables radiology departments to go beyond simply managing processes to making fundamental improvements in productivity and care processes. Unity of design translates into simplicity of operations. Integration of historically separate applications makes the environment easier to support, reduces turnaround time, and improves patient care. Conclusion: Finally, insight on new technologies and future trends in PACS, system integration and work-flow strategies will be presented in light of delivery of both clinical images and clinical data
Enewetak radiological support project. Final report
International Nuclear Information System (INIS)
Friesen, B.
1982-09-01
From 1972 through 1980, the Department of Energy acted in an advisory role to the Defense Nuclear Agency during planning for and execution of the cleanup of Enewetak Atoll. The Nevada Operations Office of the Department of Energy was responsible for the radiological characterization of the atoll and for certification of radiological condition of each island upon completion of the project. In-situ measurements of gamma rays emitted by americium-241 were utilized along with wet chemistry separation of plutonium from soil samples to identify and delineate surface areas requiring removal of soil. Military forces removed over 100,000 cubic yards of soil from the surface of five islands and deposited this material in a crater remaining from the nuclear testing period. Subsurface soil was excavated and removed from several locations where measurements indicated the presence of radionuclides above predetermined criteria. The methodologies of data acquisition, analysis and interpretation are described and detailed results are provided in text, figures and microfiche. The final radiological condition of each of 43 islets is reported
Hazardous materials package performance regulations
International Nuclear Information System (INIS)
Russell, N.A.; Glass, R.E.; McClure, J.D.; Finley, N.C.
1993-01-01
Two regulatory philosophies, one based on 'specification' packaging standards and the other based on 'performance' packaging standards, currently define the hazmat packaging certification process. A main concern when setting performance standards is determining the appropriate standards necessary to assure adequate public protection. This paper discusses a Hazmat Packaging Performance Evaluation (HPPE) project being conducted at Sandia National Laboratories for the U.S. Department of Transportation Research and Special Programs Administration. In this project, the current bulk packagings (larger than 2000 gallons) for transporting Materials Extremely Toxic By Inhalation (METBI) are being evaluated and performance standards will be recommended. A computer software system, HazCon, has been developed which can calculate the dispersion of dense, neutral, and buoyant gases. HazCon also has a database of thermodynamic and toxicity data for the METBI materials, a user-friendly menu-driven format for creating input data sets for calculating dispersion of the METBI in the event of an accidental release, and a link between the METBI database and the dense gas dispersion code (which requires thermodynamic properties). The primary output of HazCon is a listing of mass concentrations of the released material at distances downwind from the release point. (J.P.N.)
Standarized radiological hazard analysis for a broad based operational safety program
International Nuclear Information System (INIS)
Wadman, W.W. III; Andrews, L.L.
1992-01-01
The Radiological hazard Analysis (RHA) Manual provides a methodology and detailed guidance for systematic analysis of radiological hazards over a broad spectrum of program functions, housed in a wide variety of facilities. Radiological programs at LANL include: research and experimentation; routine materials operations; production; non-destructive examination or testing; isotope and machine produced radiations; chemistry; and metallurgy. The RHA permits uniform evaluation of hazard types over a range of several orders of magnitude of hazard severity. The results are used to estimate risk, evaluate types and level or resource allocations, identify deficiencies, and plan corrective actions for safe working environments. 2 refs
Standardized radiological hazard analysis for a broad based operational safety program
International Nuclear Information System (INIS)
Wadman, W. III; Andrews, L.
1992-01-01
The Radiological Hazard Analysis (RHA) Manual provides a methodology and detailed guidance for systematic analysis of radiological hazards over a broad spectrum of program functions, housed in a wide variety of facilities. Radiological programs at LANL include: research and experimentation routine materials operations; production; non-destructive examination or testing; isotope and machine produced radiations; chemistry; and metallurgy. The RHA permits uniform evaluation of hazard types over a range of several orders of magnitude of hazard severity. The results are used to estimate risk, evaluate types and level of resource allocations, identify deficiencies, and plan corrective actions for safe working environments. (author)
Pediatric interventional radiology: vascular interventions
International Nuclear Information System (INIS)
Kandasamy, Devasenathipathy; Gamanagatti, Shivanand; Gupta, Arun Kumar
2016-01-01
Pediatric interventional radiology (PIR) comprises a range of minimally invasive diagnostic and therapeutic procedures that are performed using image guidance. PIR has emerged as an essential adjunct to various surgical and medical conditions. Over the years, technology has undergone dramatic and continuous evolution, making this speciality grow. In this review, the authors will discuss various vascular interventional procedures undertaken in pediatric patients. It is challenging for the interventional radiologist to accomplish a successful interventional procedure. There are many vascular interventional radiology procedures which are being performed and have changed the way the diseases are managed. Some of the procedures are life saving and have become the treatment of choice in those patients. The future is indeed bright for the practice and practitioners of pediatric vascular and non-vascular interventions. As more and more of the procedures that are currently being performed in adults get gradually adapted for use in the pediatric population, it may be possible to perform safe and successful interventions in many of the pediatric vascular lesions that are otherwise being referred for surgery. (author)
US Department of Energy Radiological Control Manual
International Nuclear Information System (INIS)
1992-06-01
This manual establishes practices for the conduct of radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. (VC)
International Nuclear Information System (INIS)
Nolte-Ernsting, C.; Abel, K.; Krupski, G.; Lorenzen, J.; Adam, G.
2006-01-01
Purpose: To determine the economic efficiency of a whole-radiology in- and outpatient treatment with angiographic interventions performed as the main or sole therapy. Materials and Methods: The calculations represent the data of a university radiology department, including the following angiographic interventions (neuroradiology not considered): Vascular intervention (PTA, stent implantation) of kidneys and extremities, recanalization of hemodialysis access, chemoembolization, diagnostic arterioportal liver CT, port implantation, varicocele embolization, PTCD, percutaneous implantation of biliary stent. First, the different angiographic interventions are categorized with reference to the German DRG system 2005. Considering the example of a university hospital, the individual cost of each intervention is calculated and correlated with reimbursements by G-DRG2005 and so-called ''ambulant operation'' (EBM200plus). With these data, profits and losses are calculated for both in- and outpatient care. Results: Radiologic interventions of inpatients yield a profit in the majority of cases. With a base rate of 2900 Euro, the profits in our university hospital range between -872 Euro and +3411 Euro (mean: +1348 Euro). On the other hand, those angiographic interventions suitable for ''ambulant operation'' generate average profits of +372 Euro, if only direct costs are considered. The data of outpatient radiological interventions average between 381 Euro up to 1612 Euro lower than compared with profits obtained from in patient care. (orig.)
International Nuclear Information System (INIS)
Doyle, J.F. III.
1986-01-01
The Federal Radiological Emergency Response Plan (FRERP) calls for the Department of Energy to establish a Federal Radiological Monitoring and Assessment Center (FRMAC) immediately following a major radiological accident to coordinate all federal off-site monitoring efforts in support of the State and the Cognizant Federal Agency (CFA) for the facility or material involved in the accident. Some accidents are potentailly very complex and may require hundreds of radiation specialists to ensure immediate protection of the public and workers in the area, and to identify priorities for the Environmental Protection Agency (EPA) long-term efforts once the immediate protective actions have been carried out. The FRMAC provides a working environment with today's high technology tools (i.e., communication, computers, management procedures, etc.) to assure that the State and CFA decision makers have the best possible information in a timely manner on which to act. The FRMAC planners also recognize an underlying responsibility to continuously document such operations in order to provide the State, the CFA, and the EPA the technical information they will require for long term assessments. In addition, it is fully recognized that information collected and actions taken by the FRMAC will be subjected to the same scrutiny as other parts of the accident and the overall response
Establishing a health outcomes and economics center in radiology: strategies and resources required
International Nuclear Information System (INIS)
Medina, Santiago L.; Altman, Nolan R.
2002-01-01
To describe the resources and strategies required to establish a health outcomes and economics center in radiology.Methods. Human and nonhuman resources required to perform sound outcomes and economics studies in radiology are reviewed.Results. Human resources needed include skilled medical and nonmedical staff. Nonhuman resources required are: (1) communication and information network; (2) education tools and training programs; (3) budgetary strategies; and (4) sources of income. Effective utilization of these resources allows the performance of robust operational and clinical research projects in decision analysis, cost-effectiveness, diagnostic performance (sensitivity, specificity, and ROC curves), and clinical analytical and experimental studies.Conclusion. As new radiologic technology and techniques are introduced in medicine, society is increasingly demanding sound clinical studies that will determine the impact of radiologic studies on patient outcome. Health-care funding is scarce, and therefore third-party payers and hospitals are demanding more efficiency and productivity from radiologic service providers. To meet these challenges, radiology departments could establish health outcomes and economics centers to study the clinical effectiveness of imaging and its impact on patient outcome. (orig.)
International Nuclear Information System (INIS)
Mori, Hiroshige
2015-01-01
The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses’ annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units’ pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses. (practical matter)
Mori, Hiroshige
2015-06-01
The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses' annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units' pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses.
Laser additive manufacturing of high-performance materials
Gu, Dongdong
2015-01-01
This book entitled “Laser Additive Manufacturing of High-Performance Materials” covers the specific aspects of laser additive manufacturing of high-performance new materials components based on an unconventional materials incremental manufacturing philosophy, in terms of materials design and preparation, process control and optimization, and theories of physical and chemical metallurgy. This book describes the capabilities and characteristics of the development of new metallic materials components by laser additive manufacturing process, including nanostructured materials, in situ composite materials, particle reinforced metal matrix composites, etc. The topics presented in this book, similar as laser additive manufacturing technology itself, show a significant interdisciplinary feature, integrating laser technology, materials science, metallurgical engineering, and mechanical engineering. This is a book for researchers, students, practicing engineers, and manufacturing industry professionals interested i...
International Nuclear Information System (INIS)
2011-01-01
There are some basic actions and self-protective actions to take in an radiological emergency. Radiation is detected with appropriate instrumentation and measuring the rate of exposure (Sv per hour) in contact with radioactive materials involved. Is important to note: Responsive to a radiological emergency, tool to identify radiological risks, radiation protection, radioactive symbol and instrumentation
Phosphate gypsum wastes in Venice lagoon. Radiological impact
International Nuclear Information System (INIS)
Belli, M; Blasi, M; Guogang, J.; Rosamilia, S.; Sansone, U.; Biancotto, R.; Bidoli, P.; Sepulcri, D.
2000-03-01
The phosphoric minerals utilized in phosphoric acid production, presents high concentrations of radioactive materials: U238, Th 232, K 40. The phosphogypsum is the waste material obtained in the phosphoric acid production in wet process. This type of production method is employed for many years in Venice lagoon (Porto Marghera chemical plants). In this paper are reported evaluations of radiological impact on aquatic environment of lagoon [it
Energy Technology Data Exchange (ETDEWEB)
NONE
1996-08-01
Two volumes contain more than 183 complete papers presented during the Third Regional Meeting on Radiological Protection and Nuclear Safety held on 23-27 October, 1995 in Cusco-Peru. Latin american specialist talk about nuclear safety and radiological protection, radiation natural exposure, biological effect of radiation, radiotherapy and medical radiological safety, radiological safety in industry and research. Also we deal with subjects related to radiological safety of nuclear and radioactive facilities, radioactive waste management, radioactive material transport, environmental radiological monitoring program, radiological emergency and accidents, instruments and dosimetry, basic safety standards of protection against radiation.
International Nuclear Information System (INIS)
Garcia-Tenorio, R.; Bolivar, J. P.
2010-01-01
In this work it is documented why is quite limited the number os Spanish NORM industries devoted to the processing of minerals and/or raw materials where it is necessary to adopt occupational radiological protection countermeasures. These countermeasures are coincident in some cases with OHS countermeasures historically applied in the affected industries and in most cases can be only needed in working situations associated with maintenance operations. (Author) 6 refs.
Abdullahi, S.; Ismail, A. F.; Samat, S. B.; Yasir, M. S.
2018-04-01
The activity concentration and radiological risk of commonly used flooring materials (tiles) in Malaysia were studied. The natural radionuclide concentrations of 226Ra, 232Th and 40K were measured using high-purity germanium detector. The average concentration of 226Ra, 232Th and 40K in the samples were 65.75±1.1 Bq kg-1, 61.92±1.43 Bq kg-1 and 617.77±6.72 Bq kg-1 respectively. The mean concentration of radium equivalent activity, absorbed dose rate, external and internal hazard indices and annual effective dose equivalent were 195.21±2.88 Bq kg-1, 92.75±1.27 nGy h-1, 0.53±0.01, 0.7±0.01 and 0.44±0.0 mSv y-1 respectively. The aim was to assess the possible radiological risks attributed from the tile materials. Even though, the activity concentrations were higher than worldwide average values, but none of the radiological impact parameters exceeded the maximum recommended values. Hence, it was concluded that, contribution of tiles to radiation exposure is negligible and therefore, radiologically safe to use as building materials.
Kruskal, Jonathan B; Reedy, Allen; Pascal, Laurie; Rosen, Max P; Boiselle, Phillip M
2012-01-01
Many hospital radiology departments are adopting "lean" methods developed in automobile manufacturing to improve operational efficiency, eliminate waste, and optimize the value of their services. The lean approach, which emphasizes process analysis, has particular relevance to radiology departments, which depend on a smooth flow of patients and uninterrupted equipment function for efficient operation. However, the application of lean methods to isolated problems is not likely to improve overall efficiency or to produce a sustained improvement. Instead, the authors recommend a gradual but continuous and comprehensive "lean transformation" of work philosophy and workplace culture. Fundamental principles that must consistently be put into action to achieve such a transformation include equal involvement of and equal respect for all staff members, elimination of waste, standardization of work processes, improvement of flow in all processes, use of visual cues to communicate and inform, and use of specific tools to perform targeted data collection and analysis and to implement and guide change. Many categories of lean tools are available to facilitate these tasks: value stream mapping for visualizing the current state of a process and identifying activities that add no value; root cause analysis for determining the fundamental cause of a problem; team charters for planning, guiding, and communicating about change in a specific process; management dashboards for monitoring real-time developments; and a balanced scorecard for strategic oversight and planning in the areas of finance, customer service, internal operations, and staff development. © RSNA, 2012.
Directory of Open Access Journals (Sweden)
Y. Raghu
2017-07-01
Full Text Available One-hundred-fifty-one samples of six types of building materials were collected from different locations of the Tiruvannamalai District, Tamilnadu, and were analyzed using a gamma ray spectroscopy system. From the results, the highest values observed in the specific activities of 226Ra, 232Th and 40K were 116.1 (soil 106.67 (sand and 527.533 (tiles in Bq kg−1, while the lowest values observed in the specific activities of the same radionuclides were 35.73, 37.75 and 159.83 for cement in Bq kg−1, respectively. The potential radiological hazards were assessed by calculating the radium equivalent activity (Raeq, the indoor absorbed gamma dose rate (DR, the annual effective dose rate (HR, the activity utilization index (I, the alpha index (Iα, the gamma index (Iγ, and the external hazard (Hex and internal hazard (Hin indices. The estimated mean value of the absorbed dose rate of 148.35 nGy h−1 is slightly higher than the world average value of 84 nGy h−1, and the annual effective dose in the studied samples is 0.1824 mSv y−1, which is lower than the recommended limit. Multivariate statistical methods are applied to determine the existing relationship between radionuclides and radiological health hazard parameters and to identify the maximum contribution of radionuclide in radioactivity. The values of the hazard indices were below the recommended levels; therefore, it is concluded that the buildings constructed from such materials are safe for the inhabitants. The findings from this research will be useful to assess the radiation hazards of building materials in humans.
Electronic publishing in radiology: beginnings, current status, and expanding horizons.
Chew, Felix S; Llewellyn, Kevin; Olsen, Kathryn M
2004-10-01
Electronic publishing in radiology began in the 1980s and gathered momentum as use of the personal computer and subsequently the World Wide Web became commonplace. The ease of access and wide distribution that the Internet affords have presented both experts and lay users with the challenge of distinguishing reliable from unreliable material. In the field of radiology, peer-reviewed journals, the sine qua non of reliability in the scientific realm, began to appear in online versions in 1988, and now, nearly all such journals currently have online versions. Electronic versions of textbooks and textbook-like material have become more common, although the vast majority of publishers' catalogs are traditional print books. Electronic material is more common in the fields of internal, emergency, and family medicine than in the field of diagnostic radiology. The latest publishing medium is the personal digital assistant. Challenges that face electronic publishing include the issues of permanent archiving, citation, and indexing. Peer review seems to be the best method for distinguishing reliable from unreliable information. The use of Web technology has improved the logistics of peer review, and some journals have begun posting peer reviews themselves on the Web alongside peer-reviewed articles. Electronic publishing has changed the manner in which radiologists obtain information, providing wider, more immediate access.
Deep Learning to Classify Radiology Free-Text Reports.
Chen, Matthew C; Ball, Robyn L; Yang, Lingyao; Moradzadeh, Nathaniel; Chapman, Brian E; Larson, David B; Langlotz, Curtis P; Amrhein, Timothy J; Lungren, Matthew P
2018-03-01
Purpose To evaluate the performance of a deep learning convolutional neural network (CNN) model compared with a traditional natural language processing (NLP) model in extracting pulmonary embolism (PE) findings from thoracic computed tomography (CT) reports from two institutions. Materials and Methods Contrast material-enhanced CT examinations of the chest performed between January 1, 1998, and January 1, 2016, were selected. Annotations by two human radiologists were made for three categories: the presence, chronicity, and location of PE. Classification of performance of a CNN model with an unsupervised learning algorithm for obtaining vector representations of words was compared with the open-source application PeFinder. Sensitivity, specificity, accuracy, and F1 scores for both the CNN model and PeFinder in the internal and external validation sets were determined. Results The CNN model demonstrated an accuracy of 99% and an area under the curve value of 0.97. For internal validation report data, the CNN model had a statistically significant larger F1 score (0.938) than did PeFinder (0.867) when classifying findings as either PE positive or PE negative, but no significant difference in sensitivity, specificity, or accuracy was found. For external validation report data, no statistical difference between the performance of the CNN model and PeFinder was found. Conclusion A deep learning CNN model can classify radiology free-text reports with accuracy equivalent to or beyond that of an existing traditional NLP model. © RSNA, 2017 Online supplemental material is available for this article.
Cost analysis in interventional radiology-A tool to optimize management costs
International Nuclear Information System (INIS)
Clevert, D.-A.; Stickel, M.; Jung, E.M.; Reiser, M.; Rupp, N.
2007-01-01
Objective: The objective of the study was to analyze the methods to reduce cost in interventional radiology departments by reorganizing procurement. Materials and methods: All products used in Department of Interventional Radiology were inventoried. An ABC-analysis was completed and A-products (high-value and high turnover products) underwent a XYZ-analysis which predicted demand on the basis of ordering frequency. Then criteria for a procurement strategy for the different material categories were fixed. The net working capital (NWC) was calculated using an interest rate of 8%/year. Results: Total annual material turnover was 353,000 Euro . The value of all A-products determined by the inventory was 260,000 Euro . Changes in the A-product procurement strategy tapped a cost reduction potential of 14,500/year Euro . The resulting total saving was 17,200 Euro . Improved stores management added another 37,500 Euro. The total cost cut of 52,000 Euro is equivalent to 14.7% of annual expenses. Conclusion: A flexible procurement strategy helps to reduce the storage and capital tie-up costs of A-products in interventional radiology without affecting the quality of service provided to patients
Optimized determination of the radiological inventory during different phases of decommissioning
International Nuclear Information System (INIS)
Hillberg, Matthias; Beltz, Detlef; Karschnick, Oliver
2012-01-01
The decommissioning of nuclear facilities comprises a lot of activities such as decontamination, dismantling and demolition of equipment and structures. For these activities the aspects of health and safety of the operational personnel and of the general public as well as the minimization of radioactive waste have to be taken into account. An optimized, comprehensible and verifiable determination of the radiological inventory is essential for the decommissioning management with respect to safety, time, and costs. For example: right from the start of the post operational phase, the radiological characterization has to enable the decision whether to perform a system decontamination or not. Furthermore it is necessary, e.g. to determine the relevant nuclides and their composition (nuclide vector) for the release of material and for sustaining the radiological health and safety at work (e. g. minimizing the risk of incorporation). Our contribution will focus on the optimization of the radiological characterization with respect to the requisite extent and the best instant of time during the decommissioning process. For example: which additional information, besides the history of operation, is essential for an adequate amount of sampling and measurements needed in order to determine the relevant nuclides and their compositions? Furthermore, the characterization of buildings requires a kind of a graded approach during the decommissioning process. At the beginning of decommissioning, only a rough estimate of the expected radioactive waste due to the necessary decontamination of the building structures is sufficient. With ongoing decommissioning, a more precise radiological characterization of buildings is needed in order to guarantee an optimized, comprehensible and verifiable decontamination, dismantling and trouble-free clearance. These and other examples will be discussed on the background of and with reference to different decommissioning projects involving direct
Radiological shielding of low power compact reactor: calculation and design
International Nuclear Information System (INIS)
Marino, Raul
2004-01-01
The development of compact reactors becoming a technology that offers great projection and innumerable use possibilities, both in electricity generation and in propulsion.One of the requirements for the operation of this type of reactor is that it must include a radiological shield that will allow for different types of configurations and that, may be moved with the reactor if it needs to be transported.The nucleus of a reactor emits radiation, mainly neutrons and gamma rays in the heat of power, and gamma radiation during the radioactive decay of fission products.This radiation must be restrained in both conditions of operation to avoid it affecting workers or the public.The combination of different materials and properties in layers results in better performance in the form of a decrease in radiation, hence causing the dosage outside the reactor, whether in operation or shut down, to fall within the allowed limits.The calculations and design of radiological shields is therefore of paramount importance in reactor design.The choice of material and the design of the shield have a strong impact on the cost and the load capacity, the latter being one of the characteristics to optimize.The imposed condition of design is that the reactor can be transported together with the decay shield in a standard container of 40 foot [es
Surface with two paint strips for detection and warning of chemical warfare and radiological agents
Farmer, Joseph C.
2013-04-02
A system for warning of corrosion, chemical, or radiological substances. The system comprises painting a surface with a paint or coating that includes an indicator material and monitoring the surface for indications of the corrosion, chemical, or radiological substances.
Digital image information systems in radiology
International Nuclear Information System (INIS)
Greinacher, C.F.C.; Luetke, B.; Seufert, G.
1987-01-01
About 25% of all patient examinations are performed digitally in a today's radiological department. A computerized system is described that supports generation, transport, interpretation and archiving of digital radiological images (Picture Archiving and Communication System PACS). The technical features concerning image communication via local area networks, image storage on magnetic and optical media and digital workstations for image display and manipulation are described. A structured system architecture is introduced. It allows flexible adaption to individual organizations and minimizes the requirements of the communication network. (orig.) [de
Radiologic Percutaneous Gastrostomy in Nondistended Stomach: A Modified Approach
Energy Technology Data Exchange (ETDEWEB)
Petrocelli, Francesco, E-mail: francesco.petrocelli@hsanmartino.it; Salsano, Giancarlo, E-mail: giancarlo.salsano@yahoo.it; Bovio, Giulio, E-mail: giulio.bovio@hsanmartino.it; Camerano, Francesco, E-mail: francesco.camerano@gmail.com; Utili, Alice, E-mail: aliceutili@gmail.com; Ferro, Carlo, E-mail: carlo.ferro@hsanmartino.it [IRCCS San Martino University Hospital, Department of Radiology and Interventional Radiology (Italy)
2016-07-15
IntroductionGastrostomy tube placement for patients requiring long-term nutritional support may be performed using different techniques including endoscopic, surgical, and percutaneous radiologically guided methods. Radiologically inserted gastrostomy (RIG), typically performed when percutaneous endoscopic gastrostomy is not possible, requires proper gastric distension that is achieved by insufflating air through a nasogastric tube. We describe a simple technique to prevent air escape from the stomach during gastrostomy tube placement. To the best of our knowledge, this technique has not yet been described in the literature.Materials and MethodsFour patients with unsuccessful percutaneous endoscopic gastrostomy were referred for fluoroscopic-guided gastrostomy. One patient had a pyriform sinus tumor and three had an ischemic stroke causing dysphagia. Gastric distention was not achieved in the patients due to air escaping into the bowel during the standard RIG procedure. A modified approach using a balloon catheter inflated in the pylorus to avoid air passing into the duodenum permitted successful RIG.ResultsThe modified RIG procedure was successfully carried out in all cases without complications.DiscussionInadequate air distension of the stomach is an unusual event that causes a failure of gastrostomy tube placement and an increased risk of both major and minor complications. The use of a balloon catheter inflated in the first part of the duodenum prevents the air passage into the bowel allowing the correct positioning of the gastrostomy.
Bionic Design, Materials and Performance of Bone Tissue Scaffolds
Directory of Open Access Journals (Sweden)
Tong Wu
2017-10-01
Full Text Available Design, materials, and performance are important factors in the research of bone tissue scaffolds. This work briefly describes the bone scaffolds and their anatomic structure, as well as their biological and mechanical characteristics. Furthermore, we reviewed the characteristics of metal materials, inorganic materials, organic polymer materials, and composite materials. The importance of the bionic design in preoperative diagnosis models and customized bone scaffolds was also discussed, addressing both the bionic structure design (macro and micro structure and the bionic performance design (mechanical performance and biological performance. Materials and performance are the two main problems in the development of customized bone scaffolds. Bionic design is an effective way to solve these problems, which could improve the clinical application of bone scaffolds, by creating a balance between mechanical performance and biological performance.
Directory of Open Access Journals (Sweden)
Vahid Karami
2017-04-01
Full Text Available Background Increasing the x-ray film to focus distance (FFD, has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether increasing the FFD from 100 to 130 cm is equally effective for other common radiological procedures and performing a literature review of published studies to address the feasibility and probable limitations against implementing this optimization tool in clinical practice. Materials and Methods Radiographic examination of the pelvis (AP view, abdomen (AP view, skull (AP and lateral view, and spine (AP and lateral view, were taken of pediatric patients. The radiation dose and image quality of a radiological procedure is measured in FFD of 100 cm (reference FFD and 130 cm (increased FFD. The thermo-luminescent dosimeters (TLD were used for radiation dose measurements and visual grading analysis (VGA for image quality assessments. Results: Statistically significant reduction in the ESD ranged from 21.91% for the lateral skull projection to 35.24% for the lateral spine projection was obtained, when the FFD was increased from 100 to 130 cm (P0.05. Conclusion Increasing the FFD from 100 to 130 cm has significantly reduced radiation exposure without affecting on image quality. Our findings are commensurate with the literatures and emphasized that radiographers should learn to use of an updated reference FFD of 130 cm in clinical practice.
Radiologic protection in dental radiology
International Nuclear Information System (INIS)
Pacheco Jimenez, R.E.; Bermudez Jimenez, L.A.
2000-01-01
With this work and employing the radioprotection criterion, the authors pretend to minimize the risks associated to this practice; without losing the quality of the radiologic image. Odontology should perform the following criterions: 1. Justification: all operation of practice that implies exposition to radiations, should be reweighed, through an analysis of risks versus benefits, with the purpose to assure, that the total detriment will be small, compared to resultant benefit of this activity. 2. Optimization: all of the exposures should be maintained as low as reasonable possible, considering the social and economic factors. 3. Dose limit: any dose limit system should be considered as a top condition, nota as an admissible level. (S. Grainger)
International Nuclear Information System (INIS)
Wagner-Manslau, C.
1989-01-01
This radiology volume is a concise handbook of imaging techniques, nuclear medicine, and radiation therapy, albeit that the main emphasis is on classic radiology. It offers, for instance, a survey of radiological findings for the most frequent pathological conditions, many overviews of differential diagnosis, a glossary of the technical bases of radiology and so forth. The contents are divided into the following chapters: Physical and biological bases; skeleton; thorax with the subdivisions lungs, heart, mediastinum, and pleura; gastrointestinal tract with the subsections esophagus, small and large intestine; liver; biliary tract; pancreas; retroperitoneal space; kidney; suprarenal glands; bladder; blood vessels, lymph nodes, spleen; mammary glands; female genitals; prostate and scrotum, epididymis and seminal vesicle. (orig./MG) With 23 figs [de
Radiological problems in Kazakhstan
International Nuclear Information System (INIS)
Kadyrzhanov, K.K.; Lukashenko, S.N.
2001-01-01
Kazakhstan historical development and available mineral resources have pre-determined a scale of radiological problems in the state. Kazakhstan keeps leading positions in the world in explored uranium resources and hydrocarbon raw. More than five hundred nuclear explosions were performed in various regions of Kazakhstan. There is necessity to carry out remediation actions at the former test sites of Kazakhstan, especially at the Semipalatinsk test-site (STS). But because of the high cost of such actions it should be expedient to carry out them only in case of emergency and inclusion of the former test sites lands to the national economic activity, as in general, under conditions of competent policy of inhabitants, STS doesn't represent a hazard. At the same time, we ought not to lose an invaluable scientific material of test-sites. It is necessary to keep some areas of Semipalatinsk test-site as a rarities, reflected the important stages of the human evolution. Test-sites should be considered as world laboratory for studies of artificial radionuclides behaviour in natural medium. Illustrations of radiation-hazardous objects, of used technologies and procedures, under the Kazakhstan Republic instance, show that main power industries lead to the common increase of radioactivity materials in human environment. Mankind certainly will become aware of fact that industrial activities, under the current level of science and technologies development, will lead to the common increase of radioactivity materials in human environment. Solving of radioecological problems is possible only when people review their approach to a radioactivity, as a whole. Not only specialists involved in this field, but also all local population have to know rules of radiation safety and how reasonable manage with radioactive materials
Energy Technology Data Exchange (ETDEWEB)
Kim, Jae Young; Choi, Yeong Chull [Dept. of Preventive Medicine, Keimyung University College of Medicine, Daegu (Korea, Republic of); Lee, Won Jin; Cha, Eun Shil [Dept. of Preventive Medicine, Korea University College of Medicine, Seoul (Korea, Republic of)
2016-12-15
Radiologic technologists currently consist of 31.5% among diagnostic radiation workers in South Korea. Among diagnostic radiation workers, radiologic technologists receive the highest annual and collective doses in South Korea. Comprehensive assessment of the work practices and associated radiation doses from diagnostic radiology procedures should be undertaken for effective prevention for radiologic technologists. Using the national survey, this study aimed (1) to explore the distribution of the work procedures performed by gender, (2) to evaluate occupational radiation exposure by work characteristics and safety compliance, (3) to identify the primary factors influencing high radiation exposure among radiologic technologists in South Korea. This study provided detailed information on work practices, number of procedures performed on weekly basis, and occupational radiation doses among radiologic technologists in South Korea. Average radiation dose for radiologic technologists is higher than other countries, and type of facility, work safety, and wearing lead apron explained quite a portion of increased risk in the association between radiology procedures and radiation exposure among radiologic technologists.
International Nuclear Information System (INIS)
Kim, Jae Young; Choi, Yeong Chull; Lee, Won Jin; Cha, Eun Shil
2016-01-01
Radiologic technologists currently consist of 31.5% among diagnostic radiation workers in South Korea. Among diagnostic radiation workers, radiologic technologists receive the highest annual and collective doses in South Korea. Comprehensive assessment of the work practices and associated radiation doses from diagnostic radiology procedures should be undertaken for effective prevention for radiologic technologists. Using the national survey, this study aimed (1) to explore the distribution of the work procedures performed by gender, (2) to evaluate occupational radiation exposure by work characteristics and safety compliance, (3) to identify the primary factors influencing high radiation exposure among radiologic technologists in South Korea. This study provided detailed information on work practices, number of procedures performed on weekly basis, and occupational radiation doses among radiologic technologists in South Korea. Average radiation dose for radiologic technologists is higher than other countries, and type of facility, work safety, and wearing lead apron explained quite a portion of increased risk in the association between radiology procedures and radiation exposure among radiologic technologists.
Uncertainty Analysis on the Health Risk Caused by a Radiological Terror
International Nuclear Information System (INIS)
Jeong, Hyojoon; Hwang, Wontae; Kim, Eunhan; Han, Moonhee
2010-01-01
Atmospheric dispersion modeling and uncertainty analysis were carried out support the decision making in case of radiological emergency events. The risk caused by inhalation is highly dependent on air concentrations for radionuclides, therefore air monitoring and dispersion modeling have to be performed carefully to reduce the uncertainty of the health risk assessment for the public. When an intentional release of radioactive materials occurs in an urban area, air quality for radioactive materials in the environment is of great importance to take action for countermeasures and environmental risk assessments. Atmospheric modeling is part of the decision making tasks and that it is particularly important for emergency managers as they often need to take actions quickly on very inadequate information. In this study, we assume an 137 Cs explosion of 50 TBq using RDDs in the metropolitan area of Soul, South Korea. California Puff Model is used to calculate an atmospheric dispersion and transport for 137 Cs, and environmental risk analysis is performed using the Monte Carlo method
International Nuclear Information System (INIS)
MCKINNEY, S.M.
1998-01-01
This report provides a summary of the radiological surveys performed in support of near-facility environmental monitoring at the Hanford Site. The Third Quarter 1998 survey results and the status of actions required are summarized: (1) All of the eighty-five environmental radiological surveys scheduled during July, August and September were performed as planned. Fifty-one of the surveys were conducted at Project Hanford Management Contractors (PHMC) sites and thirty-four at Environmental Restoration Contractor (ERC) sites. Contamination above background levels was found at seventeen of the PHMC waste sites and two of the ERC waste sites. Contamination levels as high and gt;1,000,000 disintegrations per minute (dpm) per 100 cm(sup 2) were reported. Of these contaminated surveys nine were in Underground Radioactive Material (URM) areas, three were in unposted areas and seven were in contamination areas. The contamination found within four of the URM and three of the CA areas was immediately cleaned up and no further action was required. The remaining five URM and two unposted sites were posted and along with the five CA sites will require remediation. Radiological Problem Reports (RPR's) were issued and the sites were turned over to the landlord for further action as required. (2) During the second quarter of 1998, 1.2 hectares (3.0 acres) were stabilized and radiologically down posted from Contamination Area (CA)/Soil Contamination (SC) to URM. (3) Four hectares (10 acres) located south and west of B-Plant were posted as a radiological buffer area as a result of a contamination spread. This off-normal occurrence is currently being investigated. (4) Four Surveillance Compliance Inspection Reports (SCIRs) remained open and had not been resolved. Tank Farms Operations has responsibility for the unresolved SCIRs
Improving Communication of Diagnostic Radiology Findings through Structured Reporting
Panicek, David M.; Berk, Alexandra R.; Li, Yuelin; Hricak, Hedvig
2011-01-01
Purpose: To compare the content, clarity, and clinical usefulness of conventional (ie, free-form) and structured radiology reports of body computed tomographic (CT) scans, as evaluated by referring physicians, attending radiologists, and radiology fellows at a tertiary care cancer center. Materials and Methods: The institutional review board approved the study as a quality improvement initiative; no written consent was required. Three radiologists, three radiology fellows, three surgeons, and two medical oncologists evaluated 330 randomly selected conventional and structured radiology reports of body CT scans. For nonradiologists, reports were randomly selected from patients with diagnoses relevant to the physician’s area of specialization. Each physician read 15 reports in each format and rated both the content and clarity of each report from 1 (very dissatisfied or very confusing) to 10 (very satisfied or very clear). By using a previously published radiology report grading scale, physicians graded each report’s effectiveness in advancing the patient’s position on the clinical spectrum. Mixed-effects models were used to test differences between report types. Results: Mean content satisfaction ratings were 7.61 (95% confidence interval [CI]: 7.12, 8.16) for conventional reports and 8.33 (95% CI: 7.82, 8.86) for structured reports, and the difference was significant (P radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101913/-/DC1 PMID:21518775
High Performance Bulk Thermoelectric Materials
Energy Technology Data Exchange (ETDEWEB)
Ren, Zhifeng [Boston College, Chestnut Hill, MA (United States)
2013-03-31
Over 13 plus years, we have carried out research on electron pairing symmetry of superconductors, growth and their field emission property studies on carbon nanotubes and semiconducting nanowires, high performance thermoelectric materials and other interesting materials. As a result of the research, we have published 104 papers, have educated six undergraduate students, twenty graduate students, nine postdocs, nine visitors, and one technician.
Quality assurance programme in diagnostic radiology
International Nuclear Information System (INIS)
Yacovenco, A.A.
1996-01-01
One hundred years after the discovery of X-rays, they continue being nowadays part of physicians' daily activities, and the diagnosis through the use of X-ray equipment is one of the most important fields in clinical medicine, thus becoming the most important cause of human exposure to artificial sources. For this reason, in the last twenty years, most of the developed countries did the utmost to establish programs which could warrant the quality of the radiographic image. Aiming the protection of human being against the harmful effects of ionizing radiations, in December 1980, World Health Organization decided to form a group of professionals highly experienced in medical radiology, and initiate an inspection and quality control program. In September 1988, the Group of Studies of the Program Related to Radiological Protection of the Commission in the European Communities, prepared a working paper in which guidelines were set up regarding quality of images, dosage to patient, and associated radiographic factors, necessary to obtain acceptable radiologic performance. In Brazil, efforts driven in this direction, guided by some equipment testing, starting in 1990, began to be more known. When the Director and the Head of Radiology in the Military Police Hospital of the State of Rio de Janeiro (HPM) reamed about these efforts, they decided to contact the Institute for Radioprotection and Dosimetry (IRD) of Comissao Nacional de Energia Nuclear and submit the problem of low radiologic performance and increasing rates of rejection. Thus, with the coincidence of interests and needs, along with a proposal from the Commission of the European Communities (CEC), IRD decided to offer the author laboratory support to elaborate a Quality Assurance Program (QAP) to be implemented in HPM. (author)
International Nuclear Information System (INIS)
Langen, Heinz Jakob; Muras, S.; Kohlhauser-Vollmuth, C.; Stenzel, M.; Beer, M.
2009-01-01
A computer program was created to train technologists to perform chest X-rays in crying infants at maximum inspiration. Videos of 4 children were used. Using a computer program, the moment of deepest inspiration was determined in the video in the single frame view. During the normal running video, 14 technologists (3 with significant experience, 3 with little experience and 8 with very little experience in pediatric radiography) simulated a chest radiograph by pushing a button. The computer program stopped the video and the period of time to the optimal moment for a chest x-ray was calculated. Every technologist simulated 10 chest X-rays in each of the 4 video clips. The technologists then trained themselves to perform chest X-rays at optimal inspiration like playing a computer game. After training, the test was repeated. Changes were evaluated by t-test for unpaired samples (level of significance p < 0.05). Although the differences improved in all children, minimal deviation from the optimal moment for taking an X-ray at inspiration occurred in the periodically crying child (0.21 sec before and 0.13 sec after training). In a non-periodically crying infant, the largest differences were shown. The values improved significantly from 0.29 sec to 0.22 sec. The group with substantial experience in pediatric radiology improved significantly from 0.22 sec to 0.15 sec. The group with very little experience in pediatric radiology showed worse results (improvement from 0.29 sec to 0.21 sec). (orig.)
Marinković, Slobodan; Stošić-Opinćal, Tatjana; Tomić, Oliver
2012-07-01
The radiologic aesthetics of some body parts and internal organs have inspired certain artists to create specific works of art. Our aim was to describe the link between radiology and fine art. We explored 13,625 artworks in the literature produced by 2049 artists and found several thousand photographs in an online image search. The examination revealed 271 radiologic artworks (1.99%) created by 59 artists (2.88%) who mainly applied radiography, sonography, CT, and MRI. Some authors produced radiologic artistic photographs, and others used radiologic images to create artful compositions, specific sculptures, or digital works. Many radiologic artworks have symbolic, metaphoric, or conceptual connotations. Radiology is clearly becoming an original and important field of modern art.
Energy Technology Data Exchange (ETDEWEB)
Carton, Matthieu; Auvert, Bertran; Guerini, Henri; Boulard, Jean-Christophe; Heautot, Jean-Francois; Landre, Marie-France; Beauchet, Alain; Sznajderi, Marc; Brun-Ney, Dominique; Chagnon, Sophie
2002-02-01
AIM: To assess medical emergency radiology referral practice compared with a set of French guidelines and to measure the efficiency of computer-based guidelines on unnecessary medical imaging. MATERIALS AND METHODS: All radiological requests were computerized in the medical emergency departments of two French teaching hospitals. During control periods, radiological requests were recorded but no action was taken. During intervention periods, reminder displays on screen indicated the appropriate recommendations. Three control and three intervention periods of 1 month each were conducted. The percentage of requests that did not conform to the guidelines and variation related to periods of control and intervention were measured. RESULTS: The proportion of requests that did not conform to the guidelines was 33{center_dot}2% when the guidelines were inactive and decreased to 26{center_dot}9% when the recommendations were active (P < 0{center_dot}0001). The three imaging examinations (chest radiographs, abdominal plain radiographs and CT of the brain) accounted for more than 80% of all requests; more than 50% of abdominal plain radiographs requests did not conform with recommendations while this percentage was respectively 24{center_dot}9% and 15{center_dot}8% for chest radiographs and computed tomography (CT) of the brain. Seven situations accounted for 70% of non-conforming radiological referrals; in these situations, junior practitioners' knowledge was inadequate. CONCLUSION: While the computer provided advice that was tailored to the needs of individual patients, concurrent with care, the effect of our intervention was weak. However, our study identified the few situations that were responsible for the majority of unnecessary radiological requests; we expect that this result could help clinicians and radiologists to develop more specific actions for these situations. Carton, M. et al. (2002). Clinical Radiology (2002)
International Nuclear Information System (INIS)
Carton, Matthieu; Auvert, Bertran; Guerini, Henri; Boulard, Jean-Christophe; Heautot, Jean-Francois; Landre, Marie-France; Beauchet, Alain; Sznajderi, Marc; Brun-Ney, Dominique; Chagnon, Sophie
2002-01-01
AIM: To assess medical emergency radiology referral practice compared with a set of French guidelines and to measure the efficiency of computer-based guidelines on unnecessary medical imaging. MATERIALS AND METHODS: All radiological requests were computerized in the medical emergency departments of two French teaching hospitals. During control periods, radiological requests were recorded but no action was taken. During intervention periods, reminder displays on screen indicated the appropriate recommendations. Three control and three intervention periods of 1 month each were conducted. The percentage of requests that did not conform to the guidelines and variation related to periods of control and intervention were measured. RESULTS: The proportion of requests that did not conform to the guidelines was 33·2% when the guidelines were inactive and decreased to 26·9% when the recommendations were active (P < 0·0001). The three imaging examinations (chest radiographs, abdominal plain radiographs and CT of the brain) accounted for more than 80% of all requests; more than 50% of abdominal plain radiographs requests did not conform with recommendations while this percentage was respectively 24·9% and 15·8% for chest radiographs and computed tomography (CT) of the brain. Seven situations accounted for 70% of non-conforming radiological referrals; in these situations, junior practitioners' knowledge was inadequate. CONCLUSION: While the computer provided advice that was tailored to the needs of individual patients, concurrent with care, the effect of our intervention was weak. However, our study identified the few situations that were responsible for the majority of unnecessary radiological requests; we expect that this result could help clinicians and radiologists to develop more specific actions for these situations. Carton, M. et al. (2002). Clinical Radiology (2002)
International Nuclear Information System (INIS)
Groves, Ken L.
2008-01-01
Full text: This paper will present an overview of the current training the author is presenting to First Responders (fire-fighters, emergency medical technicians, law enforcement and others) who may encounter either a Radiological Dispersal Device (RDD or Dirty Bomb) or an Improvised Nuclear Device (IND) as a part of their Emergency Response activities. The emphasis of the training is putting the radiological/nuclear material in perspective as compared with other Weapons of Mass Destruction (WMD) materials such as chemical and/or biological weapon agents. A goal of the training is to help this First Responder Community understand that under almost all conditions, they can perform their primary mission of 'putting out fires', rescuing and treating injured persons, and chasing 'bad guys' even in the presence of relatively large amount of radiological/nuclear contamination. The rare cases of high activity unshielded sources will be reviewed and explained. Current International guidance on dose 'limits' will be discussed. A discussion of the use of Time, Distance and Shielding as well as appropriate Personal Protective Clothing and how it will provide the needed protection while immediate actions take place early in an RDD/IND event, will take place. The use of appropriate radiation detection instrumentation, documented Standard Operating Procedures along with realistic training, drills and exercises are the key to a successful response to an RDD/IND event for this community of critical emergency responders. (author)
Pediatric interventional radiology clinic - how are we doing?
International Nuclear Information System (INIS)
Rubenstein, Jonathan; Zettel, Julie C.; Lee, Eric; Cote, Michelle; Aziza, Albert; Connolly, Bairbre L.
2016-01-01
Development of a pediatric interventional radiology clinic is a necessary component of providing a pediatric interventional radiology service. Patient satisfaction is important when providing efficient, high-quality care. To analyze the care provided by a pediatric interventional radiology clinic from the perspective of efficiency and parent satisfaction, so as to identify areas for improvement. The prospective study was both quantitative and qualitative. The quantitative component measured clinic efficiency (waiting times, duration of clinic visit, nurse/physician time allocation and assessments performed; n = 91). The qualitative component assessed parental satisfaction with their experience with the pediatric interventional radiology clinic, using a questionnaire (5-point Likert scale) and optional free text section for feedback (n = 80). Questions explored the family's perception of relevance of information provided, consent process and overall satisfaction with their pediatric interventional radiology clinic experience. Families waited a mean of 11 and 10 min to meet the physician and nurse, respectively. Nurses and physicians spent a mean of 28 and 21 min with the families, respectively. The average duration of the pediatric interventional radiology clinic consultation was 56 min. Of 80 survey participants, 83% were satisfied with their experience and 94% said they believed providing consent before the day of the procedure was helpful. Only 5% of respondents were not satisfied with the time-efficiency of the interventional radiology clinic. Results show the majority of patients/parents are very satisfied with the pediatric interventional radiology clinic visit. The efficiency of the pediatric interventional radiology clinic is satisfactory; however, adherence to stricter scheduling can be improved. (orig.)
Chemical and radiological vulnerability assessment in urban areas
Directory of Open Access Journals (Sweden)
Stojanović Božidar
2006-01-01
Full Text Available Cities and towns are faced with various types of threat from the extraordinary events involving chemical and radiological materials as exemplified by major chemical accidents, radiological incidents, fires, explosions, traffic accidents, terrorist attacks, etc. On the other hand, many sensitive or vulnerable assets exist within cities, such as: settlements, infrastructures, hospitals, schools, churches, businesses, government, and others. Besides emergency planning, the land use planning also represents an important tool for prevention or reduction of damages on people and other assets due to unwanted events. This paper considers development of method for inclusion vulnerability assessment in land use planning with objective to assess and limit the consequences in cities of likely accidents involving hazardous materials. We made preliminary assessment of criticality and vulnerability of the assets within Belgrade city area in respect to chemical sites and transportation roads that can be exposed to chemical accidents, or terrorist attacks.
Radiological contamination control training for laboratory research
International Nuclear Information System (INIS)
1997-02-01
This program management guide describes the proper implementation standard for core training as outlined in the DOE Radiological Control (RadCon) Manual. The guide is to assist those individuals, both within the Department of Energy (DOE) and Managing and Operating (M and O) contractors, identified as having responsibility for implementing the core training recommended by the RadCon Manual. The management guide is divided into the following sections: introduction; instructional materials development; training program standards and policies; and course-specific information. The goal of the core training program is to provide a standardized, baseline knowledge for those individuals completing the core training. Standardization of the knowledge provides personnel with the information necessary to perform their assigned duties at a predetermined level of expertise. Implementing a core training program ensures consistent and appropriate training of personnel
International Nuclear Information System (INIS)
2001-01-01
An International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy organized by the International Atomic Energy Agency and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization was held in Malaga, Spain, from 26 to 30 March 2001. The Government of Spain hosted this Conference through the Ministerio de Sanidad y Consumo, the Consejo de Seguridad Nuclear, the Junta de Andalucia, the Universidad de Malaga and the Grupo de Investigacion en Proteccion Radiologica de la Universidad de Malaga (PRUMA). The Conference was organized in co-operation with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP) and the following professional societies: International Organization of Medical Physicists (IOMP), International Radiation Protection Association (IRPA), International Society of Radiation Oncology (ISRO), International Society of Radiology (ISR), International Society of Radiographers and Radiological Technologists (ISRRT) and World Federation of Nuclear Medicine and Biology (WFNMB). This publication contains contributed papers submitted to the Conference Programme Committee. The papers are in one of the two working languages of this Conference, English and Spanish. The topics covered by the Conference are as follows: Radiological protection of patients in general diagnostic radiology (radiography), Radiological protection of patients in general diagnostic radiology (fluoroscopy), Radiological protection issues in specific uses of diagnostic radiology, such as mammography and computed tomography (with special consideration of the impact of digital techniques), Radiological protection in interventional radiology, including fluoroscopy not carried out by radiologists, Radiological protection of patients in nuclear medicine, Developing and
Energy Technology Data Exchange (ETDEWEB)
NONE
2001-03-01
An International Conference on the Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy organized by the International Atomic Energy Agency and co-sponsored by the European Commission, the Pan American Health Organization and the World Health Organization was held in Malaga, Spain, from 26 to 30 March 2001. The Government of Spain hosted this Conference through the Ministerio de Sanidad y Consumo, the Consejo de Seguridad Nuclear, the Junta de Andalucia, the Universidad de Malaga and the Grupo de Investigacion en Proteccion Radiologica de la Universidad de Malaga (PRUMA). The Conference was organized in co-operation with the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), the International Commission on Radiological Protection (ICRP) and the following professional societies: International Organization of Medical Physicists (IOMP), International Radiation Protection Association (IRPA), International Society of Radiation Oncology (ISRO), International Society of Radiology (ISR), International Society of Radiographers and Radiological Technologists (ISRRT) and World Federation of Nuclear Medicine and Biology (WFNMB). This publication contains contributed papers submitted to the Conference Programme Committee. The papers are in one of the two working languages of this Conference, English and Spanish. The topics covered by the Conference are as follows: Radiological protection of patients in general diagnostic radiology (radiography), Radiological protection of patients in general diagnostic radiology (fluoroscopy), Radiological protection issues in specific uses of diagnostic radiology, such as mammography and computed tomography (with special consideration of the impact of digital techniques), Radiological protection in interventional radiology, including fluoroscopy not carried out by radiologists, Radiological protection of patients in nuclear medicine, Developing and
International Nuclear Information System (INIS)
Kwak, Sung Woo; Jang, Sung Soon; Lee, Joung Hoon; Yoo, Ho Sik
2009-01-01
Since 1990s, some events - detection of a dirty bomb in a Russian nation park in 1995, 9/11 terrorist attack to WTC in 2001, discovery of Al-Qaeda's experimentation to build a dirty bomb in 2003 etc - have showed that nuclear or radiological terrorism relating to radioactive materials (hereinafter 'radioactive materials' is referred to as 'nuclear material, nuclear spent fuel and radioactive source') is not incredible but serious and credible threat. Thus, to respond to the new threat, the international community has not only strengthened security and physical protection of radioactive materials but also established prevention of and response to illicit trafficking of radioactive materials. In this regard, our government has enacted or revised the national regulatory framework with a view to improving security of radioactive materials and joined the international convention or agreement to meet this international trend. For the purpose of prevention of nuclear/radiological terrorism, this paper reviews physical characteristics of nuclear material and existing detection instruments used for prevention of illicit trafficking. Finally, national detection regime against nuclear/radiological terrorism based on paths of the smuggled radioactive materials to terrorist's target building/area, national topography and road networks, and defence-in-depth concept is suggested in this paper. This study should contribute to protect people's health, safety and environment from nuclear/radiological terrorism
International Nuclear Information System (INIS)
Kemp, A.M.; Butler, A.; Morris, S.; Mann, M.; Kemp, K.W.; Rolfe, K.; Sibert, J.R.; Maguire, S.
2006-01-01
Aims: To determine which radiological investigations should be performed and which children should be investigated. Materials and methods: An all language literature search of original articles; from 1950-October 2005. Two reviewers independently reviewed each article. A third was carried out on disagreement. Each study was assessed using standardised data extraction, critical appraisal and evidence forms. Results: Thirty-four studies were included. Fifteen addressed the question: which investigation has a higher yield, skeletal surveys (SS) or bone scintigraphy (BS)? Studies gave conflicting results. Overall neither investigation is as good as the two combined. BS predominately missed skull, metaphyseal and epiphyseal fractures, whereas SS commonly missed rib fractures. Two studies showed that a repeat SS 2 weeks after the initial study provided significant additional information about tentative findings, the number and age of fractures. A comparative study evaluated additional oblique views of ribs in 73 children and showed improved diagnostic sensitivity, specificity and accuracy. Four studies addressed the diagnostic yield for occult fractures with respect to age. This was significant for children under 2-years old. Conclusions: In children under 2-years old, where physical abuse is suspected, diagnostic imaging of the skeleton should be mandatory. SS or BS alone is inadequate to identify all fractures. It is recommended that all SS should include oblique views of the ribs. This review suggests that the following options would optimize the diagnostic yield. However, each needs to be evaluated prospectively: SS that includes oblique views, SS and BS, a SS with repeat SS or selected images 2 weeks later or a BS plus skull radiography and coned views of metaphyses and epiphyses
Energy Technology Data Exchange (ETDEWEB)
Kemp, A.M.; Butler, A.; Morris, S.; Mann, M.; Kemp, K.W.; Rolfe, K.; Sibert, J.R.; Maguire, S
2006-09-15
Aims: To determine which radiological investigations should be performed and which children should be investigated. Materials and methods: An all language literature search of original articles; from 1950-October 2005. Two reviewers independently reviewed each article. A third was carried out on disagreement. Each study was assessed using standardised data extraction, critical appraisal and evidence forms. Results: Thirty-four studies were included. Fifteen addressed the question: which investigation has a higher yield, skeletal surveys (SS) or bone scintigraphy (BS)? Studies gave conflicting results. Overall neither investigation is as good as the two combined. BS predominately missed skull, metaphyseal and epiphyseal fractures, whereas SS commonly missed rib fractures. Two studies showed that a repeat SS 2 weeks after the initial study provided significant additional information about tentative findings, the number and age of fractures. A comparative study evaluated additional oblique views of ribs in 73 children and showed improved diagnostic sensitivity, specificity and accuracy. Four studies addressed the diagnostic yield for occult fractures with respect to age. This was significant for children under 2-years old. Conclusions: In children under 2-years old, where physical abuse is suspected, diagnostic imaging of the skeleton should be mandatory. SS or BS alone is inadequate to identify all fractures. It is recommended that all SS should include oblique views of the ribs. This review suggests that the following options would optimize the diagnostic yield. However, each needs to be evaluated prospectively: SS that includes oblique views, SS and BS, a SS with repeat SS or selected images 2 weeks later or a BS plus skull radiography and coned views of metaphyses and epiphyses.
Accountable care organizations and radiology: threat or opportunity?
Abramson, Richard G; Berger, Paul E; Brant-Zawadzki, Michael N
2012-12-01
Although the anticipated rise of accountable care organizations brings certain potential threats to radiologists, including direct threats to revenue and indirect systemic changes jeopardizing the bargaining leverage of radiology groups, accountable care organizations, and other integrated health care delivery models may provide radiology with an important opportunity to reassert its leadership and assume a more central role within health care systems. Capitalizing on this potential opportunity, however, will require radiology groups to abandon the traditional "film reader" mentality and engage actively in the design and implementation of nontraditional systems service lines aimed at adding differentiated value to larger health care organizations. Important interlinked and mutually reinforcing components of systems service lines, derived from radiology's core competencies, may include utilization management and decision support, IT leadership, quality and safety assurance, and operational enhancements to meet organizational goals. Such systems-oriented service products, tailored to the needs of individual integrated care entities and supported by objective performance metrics, may provide market differentiation to shield radiology from commoditization and could become an important source of new nonclinical revenue. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Radiology and the mobile device: Radiology in motion
Directory of Open Access Journals (Sweden)
Sridhar G Panughpath
2012-01-01
Full Text Available The use of mobile devices is revolutionizing the way we communicate, interact, are entertained, and organize our lives. With healthcare in general and radiology in particular becoming increasingly digital, the use of such devices in radiologic practice is inevitable. This article reviews the current status of the use of mobile devices in the clinical practice of radiology, namely in emergency teleradiology. Technical parameters such as luminance and resolution are discussed. The article also discusses the benefits of such mobility vis-à-vis the current limitations of the technologies available.
Radiology and the mobile device: Radiology in motion
International Nuclear Information System (INIS)
Panughpath, Sridhar G; Kalyanpur, Arjun
2012-01-01
The use of mobile devices is revolutionizing the way we communicate, interact, are entertained, and organize our lives. With healthcare in general and radiology in particular becoming increasingly digital, the use of such devices in radiologic practice is inevitable. This article reviews the current status of the use of mobile devices in the clinical practice of radiology, namely in emergency teleradiology. Technical parameters such as luminance and resolution are discussed. The article also discusses the benefits of such mobility vis-à-vis the current limitations of the technologies available
Performance analysis of nuclear materials accounting systems
International Nuclear Information System (INIS)
Cobb, D.D.; Shipley, J.P.
1979-01-01
Techniques for analyzing the level of performance of nuclear materials accounting systems in terms of the four performance measures, total amount of loss, loss-detection time, loss-detection probability, and false-alarm probability, are presented. These techniques are especially useful for analyzing the expected performance of near-real-time (dynamic) accounting systems. A conservative estimate of system performance is provided by the CUSUM (cumulative summation of materials balances) test. Graphical displays, called performance surfaces, are developed as convenient tools for representing systems performance, and examples from a recent safeguards study of a nuclear fuels reprocessing plant are given. 6 refs
International Nuclear Information System (INIS)
Larsson, Arne; Weber, Inge
2016-01-01
Radiological characterisation plays a significant role in the process of decommissioning of shut-down nuclear facilities in order to ensure the protection of the environment and radiation safety. At all stages of a decommissioning programme or project, adequate radiological characterisation is of crucial importance, not least from a material and waste perspective. The radiological characterisation is a key element for planning, controlling and optimising decommissioning and dismantling activities. Experience has shown that data and information from the operation of a facility can - supplemented by recently collected and analysed data and information - be of crucial importance for decisions on waste management and for characterisation of radioactive waste. Once the dismantling has been done, some information may be hard, costly or even impossible to obtain later in the waste management process. This was the reason why the Working Party on Decommissioning and Dismantling (WPDD) of the OECD Nuclear Energy Agency (NEA) decided in late 2013 to extend the mandate of the Task Group on Radiological Characterisation and Decommissioning (TGRCD) for a second phase focusing on nuclear facility characterisation from a waste and material end-state perspective whereas the first phase focused on overall strategies of radiological characterisation. This paper gives an overview of the activities and findings within both phases up to now. (authors)
International Nuclear Information System (INIS)
Kim, Seon Chil
2008-01-01
Distribution of microorganisms were examined for the bucky tables in the radiology rooms of the department of radiological technology, the aprons, handles of various apparatus, handles of mobile radiological apparatus, and hands of the radiological technologists. As a result, relatively larger amounts of bacteria were found on the handles of the mobile radiological apparatus and the aprons. Among the isolated bacteria, Acinetobacter baumanni (7.3%), Klebsiella pneumoniae (6.7%), Staphylococcus aureus (3.9%), Serratia liquefaciens (1.7%), Enterobacter cloaceae (0.6%), Providenica rettgeri (0.6%) are known as the cause of nosocomial infection (hospital acquired infection). In addition, similar colonies were also found on the hands of the radiological technologists such as microorganisms of Klebsiella pneumoniae (8.4%), Staphylococcus aureus (6.6%), Yersinia enterocolotica (5.4%), Acinetobacter baumanni (4.2%), Enterobacter cloaceae (2.4%), Serratia liquefaciens (1.8%), Yersinia pseuotuberculosis (18%), Enterobacter sakazakii (1.2%), and Escherichia coli (0.6%). In particular, this result indicates clinical significance since Staphylococcus aureus and Escherichia coli show strong pathogenicity. Therefore, a continuous education is essential for the radiological technologists to prevent the nosocomial infection.
Energy Technology Data Exchange (ETDEWEB)
Kim, Seon Chil [Dept. of Radiologic Technology, Daegu Health College, Daegu (Korea, Republic of)
2008-12-15
Distribution of microorganisms were examined for the bucky tables in the radiology rooms of the department of radiological technology, the aprons, handles of various apparatus, handles of mobile radiological apparatus, and hands of the radiological technologists. As a result, relatively larger amounts of bacteria were found on the handles of the mobile radiological apparatus and the aprons. Among the isolated bacteria, Acinetobacter baumanni (7.3%), Klebsiella pneumoniae (6.7%), Staphylococcus aureus (3.9%), Serratia liquefaciens (1.7%), Enterobacter cloaceae (0.6%), Providenica rettgeri (0.6%) are known as the cause of nosocomial infection (hospital acquired infection). In addition, similar colonies were also found on the hands of the radiological technologists such as microorganisms of Klebsiella pneumoniae (8.4%), Staphylococcus aureus (6.6%), Yersinia enterocolotica (5.4%), Acinetobacter baumanni (4.2%), Enterobacter cloaceae (2.4%), Serratia liquefaciens (1.8%), Yersinia pseuotuberculosis (18%), Enterobacter sakazakii (1.2%), and Escherichia coli (0.6%). In particular, this result indicates clinical significance since Staphylococcus aureus and Escherichia coli show strong pathogenicity. Therefore, a continuous education is essential for the radiological technologists to prevent the nosocomial infection.
Terrorism: the threat of a radiological device
International Nuclear Information System (INIS)
Kingshott, B.F.
2005-01-01
Full text: This paper will discuss terrorism from the perspective of a terrorist organization building and detonating a 'dirty bomb' with a radiological component. The paper will discuss how such devices are made and how security of radiological material world wide will minimize the risk of such devices being used. It will discuss the threat assessments against nuclear waste processing and storage sites, threats to nuclear plants and other sites and the adequacy of current security. It will also discuss the phenomenon of suicide attacks by the bomb carriers and the role of the media in informing and educating the general public of the consequences should such a device be detonated. (author)
A TWO-STAGE MODEL OF RADIOLOGICAL INSPECTION: SPENDING TIME
International Nuclear Information System (INIS)
BROWN, W.S.
2000-01-01
The paper describes a model that visually portrays radiological survey performance as basic parameters (surveyor efficiency and criteria, duration of pause, and probe speed) are varied; field and laboratory tests provided typical parameter values. The model is used to illustrate how practical constraints on the time allotted to the task can affect radiological inspection performance. Similar analyses are applicable to a variety of other tasks (airport baggage inspection, and certain types of non-destructive testing) with similar characteristics and constraints
Solutions in radiology services management: a literature review
Directory of Open Access Journals (Sweden)
Aline Garcia Pereira
2015-10-01
Full Text Available AbstractObjective:The present study was aimed at reviewing the literature to identify solutions for problems observed in radiology services.Materials and Methods:Basic, qualitative, exploratory literature review at Scopus and SciELO databases, utilizing the Mendeley and Illustrator CC Adobe softwares.Results:In the databases, 565 papers – 120 out of them, pdf free – were identified. Problems observed in the radiology sector are related to procedures scheduling, humanization, lack of training, poor knowledge and use of management techniques, and interaction with users. The design management provides the services with interesting solutions such as Benchmarking, CRM, Lean Approach, ServiceBlueprinting, continued education, among others.Conclusion:Literature review is an important tool to identify problems and respective solutions. However, considering the small number of studies approaching management of radiology services, this is a great field of research for the development of deeper studies.
Solutions in radiology services management: a literature review*
Pereira, Aline Garcia; Vergara, Lizandra Garcia Lupi; Merino, Eugenio Andrés Díaz; Wagner, Adriano
2015-01-01
Objective The present study was aimed at reviewing the literature to identify solutions for problems observed in radiology services. Materials and Methods Basic, qualitative, exploratory literature review at Scopus and SciELO databases, utilizing the Mendeley and Illustrator CC Adobe softwares. Results In the databases, 565 papers – 120 out of them, pdf free – were identified. Problems observed in the radiology sector are related to procedures scheduling, humanization, lack of training, poor knowledge and use of management techniques, and interaction with users. The design management provides the services with interesting solutions such as Benchmarking, CRM, Lean Approach, ServiceBlueprinting, continued education, among others. Conclusion Literature review is an important tool to identify problems and respective solutions. However, considering the small number of studies approaching management of radiology services, this is a great field of research for the development of deeper studies. PMID:26543281
International Nuclear Information System (INIS)
1987-03-01
The increasing use of radioactive materials and the increasing public concern about possible accidents involving these materials has led to greater emphasis on preparing for such emergencies. The ANS Topical Meeting on Radiological Accidents - Perspectives and Emergency Planning provided a review of experiences with radiological accidents. The meeting covered some of the most important aspects of radiological accidents. Papers were presented which dealt with radiological accident experience. Technical response to accidents is of primary interest to many in the nuclear community; most of the papers submitted fell into this area. So many of these papers dealt with the use of computers in response that a session on that topic was arranged. A very significant impact of most radiological accidents is the cost, especially the cost of cleanup. There were papers on what is known about costs and associated current topics, such as modification and extension of the Price-Anderson Act. At least as important as the technical response to accidents is how society attempts to deal with them. A session on institutional issues was included to discuss how governments and other organizations respond to and deal with accidents. Medical effects of accidents are of great concern to the public. Invited papers to review the effects of high doses of radiation as well as very low doses were included in that session. Although the nuclear industry has an excellent safety record, this fact often does not agree with the public perception of the industry. The final session explored the public response to and perception of radiological emergencies and accidents. This subject will ultimately determine the future use of radioactive materials in this country
Guidelines on radiology standards for primary dental care
International Nuclear Information System (INIS)
1994-01-01
A Joint Working Party (JWP) on patient dose reduction in diagnostic radiology was established between the Royal College of Radiologists (RCR) and the National Radiological Protection Board (NRPB) towards the end of 1988. JWP identified a large potential for patient dose reduction on a national scale, and a report of its findings was published in 1990. This guidance was only generally applicable to dental radiology and in 1992 a further joint venture between RCR and NRPB resulted in the formation of a Working Party (WP) to consider all aspects of dental radiology applicable to primary dental care. Dental radiology is one of the largest single groups of radiographic examination performed, although the effective dose per radiograph is small. This means that individual risks from dental radiology are low, but WP has identified a significant potential for reduction in the collective dose and for improvements in the diagnostic quality of radiographs. The WP recommendations cover all aspects of dental radiology: training and examination regimes for dentists and staff, patient selection and clinical justification for radiography, diagnostic interpretation, equipment and procedural aspects, and finally the question of quality assurance in dental radiology. The economic impact of the many recommendations by WP has been considered in some detail. The benefits and cost of each recommendation either have been assigned a monetary value or have been assessed more qualitatively. The conclusion is that there is a strong economic justification for implementation of the full package of recommendations. (Author)