WorldWideScience

Sample records for perform photographic sampling

  1. Apollo Lunar Sample Photographs: Digitizing the Moon Rock Collection

    Science.gov (United States)

    Lofgren, Gary E.; Todd, Nancy S.; Runco, S. K.; Stefanov, W. L.

    2011-01-01

    The Acquisition and Curation Office at JSC has undertaken a 4-year data restoration project effort for the lunar science community funded by the LASER program (Lunar Advanced Science and Exploration Research) to digitize photographs of the Apollo lunar rock samples and create high resolution digital images. These sample photographs are not easily accessible outside of JSC, and currently exist only on degradable film in the Curation Data Storage Facility

  2. Determination of ruthenium in photographic emulsions - Development and comparison of different sample treatments and mass spectrometric methods

    NARCIS (Netherlands)

    Krystek, Petra; Heumann, Klaus G.

    1999-01-01

    Different sample treatment procedures were combined with inductively coupled plasma mass spectrometry (ICP-MS) and negative thermal ionisation mass spectrometry (NTI-MS) for the determination of ruthenium traces in photographic emulsions. Dissolution of the samples in concentrated ammonia solution

  3. An evaluation of inductively coupled plasma optical emission spectrometry using electrothermal atomisation sample introduction and photographic plate detection

    International Nuclear Information System (INIS)

    Khathing, D.T.; Pickford, C.J.

    1984-05-01

    A photographic radiation measurement approach has been used with an inductively coupled plasma source to evaluate and tabulate the more prominent optical emission lines of 66 elements. Compared with the more common sample introduction technique using nebulisation, increased sensitivity for multielement analysis of small samples was achieved by using a simple graphite electrothermal atomisation system. This was constructed to serve as a dual purpose atomiser ie both for Atomic Absorption and for Inductively Coupled Plasma Emission spectroscopy. The system offers the advantage of a wide multi-elemental coverage, but sensitivities achieved with photographic detection are poorer than those obtained photoelectrically. (author)

  4. Reframing the photograph: confronting the Nazi past through artistic performance strategies since the 1960s

    OpenAIRE

    Allwork, Larissa

    2015-01-01

    Working in a period when the western modernist focus on the originality of the artist, painterly form and composition had given way to more post Duchampian practices such as reappropriation, performance and the role of the spectator in creating artistic meaning, this paper will focus on works by Gerhard Richter, Anselm Kiefer and Gustav Metzger. This paper will evaluate how these artists perform the photograph in three divergent yet distinctly post-Duchampian ways in order to articulate chall...

  5. New color-photographic observation of thermoluminescence from sliced rock samples

    International Nuclear Information System (INIS)

    Hashimoto, Tetsuo; Kimura, Kenichi; Koyanagi, Akira; Takahashi, Kuniaki; Sotobayashi, Takeshi

    1983-01-01

    New observation technique has been established for the thermoluminescence photography using extremely high-sensitive color films. Considering future application to the geological fields, a granite was selected as a testing material. The sliced specimens (0.5--0.7 mm in thickness), which were irradiated with a 60 Co source, were mounted on the heater attached with a thermocouple, which was connected to a microcomputer for measuring the temperature. The samples were heated in the temperature range of 80--400 0 C by operating the camera-shutter controlled with the microcomputer. Four commercially available films (Kodak-1000(ASA), -400, Sakura-400, Fuji-400) could give apparently detectable color-images of artificial thermoluminescence above a total absorbed dose of 880 Gy(88 krad). The specimens, irradiated upto 8.4 kGy(840krad), allowed easily to distinguish the distinct appearance of the thermoluminescence images depending on kinds of white mineral constituents. Moreover, such color images were changeable with the heating temperature. Sakura-400 film has proved the most colorful images from aspects of color tone although Kodak-1000 film showed the highest sensitivity. By applying this Kodak-1000, it was found that the characteristic color image due to natural thermoluminescence was significantly observed on the Precambrian granite which was exposed with natural radiation alone since its formation. This simple and interesting technique, obtainable surface information reflecting impurities and local crystal defects in addition to small mineral constituents, was named as the thermoluminescence color imaging (abbreviated to TLCI) technique by the authors and its versatile applications were discussed. (author)

  6. Performance samples on academic tasks : improving prediction of academic performance

    NARCIS (Netherlands)

    Tanilon, Jenny

    2011-01-01

    This thesis is about the development and validation of a performance-based test, labeled as Performance Samples on academic tasks in Education and Child Studies (PSEd). PSEd is designed to identify students who are most able to perform the academic tasks involved in an Education and Child Studies

  7. Predicting sample size required for classification performance

    Directory of Open Access Journals (Sweden)

    Figueroa Rosa L

    2012-02-01

    Full Text Available Abstract Background Supervised learning methods need annotated data in order to generate efficient models. Annotated data, however, is a relatively scarce resource and can be expensive to obtain. For both passive and active learning methods, there is a need to estimate the size of the annotated sample required to reach a performance target. Methods We designed and implemented a method that fits an inverse power law model to points of a given learning curve created using a small annotated training set. Fitting is carried out using nonlinear weighted least squares optimization. The fitted model is then used to predict the classifier's performance and confidence interval for larger sample sizes. For evaluation, the nonlinear weighted curve fitting method was applied to a set of learning curves generated using clinical text and waveform classification tasks with active and passive sampling methods, and predictions were validated using standard goodness of fit measures. As control we used an un-weighted fitting method. Results A total of 568 models were fitted and the model predictions were compared with the observed performances. Depending on the data set and sampling method, it took between 80 to 560 annotated samples to achieve mean average and root mean squared error below 0.01. Results also show that our weighted fitting method outperformed the baseline un-weighted method (p Conclusions This paper describes a simple and effective sample size prediction algorithm that conducts weighted fitting of learning curves. The algorithm outperformed an un-weighted algorithm described in previous literature. It can help researchers determine annotation sample size for supervised machine learning.

  8. Performance evaluation soil samples utilizing encapsulation technology

    Science.gov (United States)

    Dahlgran, James R.

    1999-01-01

    Performance evaluation soil samples and method of their preparation using encapsulation technology to encapsulate analytes which are introduced into a soil matrix for analysis and evaluation by analytical laboratories. Target analytes are mixed in an appropriate solvent at predetermined concentrations. The mixture is emulsified in a solution of polymeric film forming material. The emulsified solution is polymerized to form microcapsules. The microcapsules are recovered, quantitated and introduced into a soil matrix in a predetermined ratio to form soil samples with the desired analyte concentration.

  9. Photographic Tourism Research: Literature Review

    OpenAIRE

    Virdee, Inderpal

    2017-01-01

    This study reviews the current photographic tourism literature to identify what fields within tourism have been studied by researchers, the contexts, the samples used, the sampling methods employed, the photographic methods and supporting methods used, the data analysis techniques applied and the countries studied. A set of 115 relevant academic articles were selected and assessed using content analysis. The findings showed that overall publications in the field of photographic tourism increa...

  10. Oblique Photographs

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set includes photographs of marine mammals and sea turtles taken in the field. Most are lateral views of animals that are used to confirm species identity...

  11. Vertical Photographs

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set includes of photographs of marine mammals and sea turtles taken with high resolution cameras mounted in airplanes, unmanned platforms or the bow of...

  12. Radiography using photographic paper

    International Nuclear Information System (INIS)

    Gromov, Yu.V.; Kapustin, V.I.; Volkova, T.G.

    1982-01-01

    The possibility of radiographic control with application of ''Fototelegrafnaya BS'' photographic paper in conjunction with the ''Standart'' image intensifier as an X-ray image converter is studied. Investigations were made using steel samples 5 to 45 mm thick, X-ray radiation energy varied from 80 to 240 keV. Specifications of the image intensifier of the ''Standart type and photographic paper are given. It is shown, that the photographic paper improves the sensitivity of the method to the detection of small defects. The method provides standard and panoramic radioscopy, conservation of objective documentation, enables one to mechanize and automatize the process of photodevelopment. The application of the photographic paper is beneficial, its cost being six times as low as that of X-ray film

  13. Matching Faces to Photographs: Poor Performance in Eyewitness Memory (without the Memory)

    Science.gov (United States)

    Megreya, Ahmed M.; Burton, A. Mike

    2008-01-01

    Eyewitness memory is known to be fallible. We describe 3 experiments that aim to establish baseline performance for recognition of unfamiliar faces. In Experiment 1, viewers were shown live actors or photos (targets), and then immediately presented with arrays of 10 faces (test items). Asked whether the target was present among the test items, and…

  14. Performing the nation between us: urban photographic sets with young migrants

    Directory of Open Access Journals (Sweden)

    Tania Rossetto

    2015-08-01

    Full Text Available First developed during the 1990s, the transnational paradigm in the study of migration has been associated with the notions of displacement, deterritorialisation and frictionless-ness. In more recent times, there has been a growing tendency to spatially ground transnational studies by locating and emplacing transnational practices. The emergence of the so-called transnational urbanism has led to a prolific urban stream within transnational research. With respect to the growing diversity of Western societies, this literature has tended to emphasise the potentialities of the city as the location of lived diversity, sharing, dynamism, vibrancy and encounter, in contrast to the deficiencies of the nation, identified with formal politics, discourse and ideology, singular belonging, fixity and constraint. Against this narrative of the city/nation divide, this article draws attention to the alternative conceptualisations of the nation that have emerged in recent debates and have embraced local, material and agency-based, rather than discursively-oriented approaches to the nation. As well as the city/nation divide, a progressive idea of the nation as shared experiences is analysed within an urban performance project which involved young migrants in the city of Padua (Italy during winter 2013. These performances are read from the particular perspective of the scale debate, suggesting that, through the performance of urban heritage sites, those migrants physically and emotionally locate themselves within the hosting nation. Finally, I discuss this scalar shift and I propose extrapolating the concept of the “urban unconscious” to the national level, thus suggesting a way to think about the nation as a frame of co-existence and not as an identity bond.

  15. Clinical Strategies for Sampling Word Recognition Performance.

    Science.gov (United States)

    Schlauch, Robert S; Carney, Edward

    2018-04-17

    Computer simulation was used to estimate the statistical properties of searches for maximum word recognition ability (PB max). These involve presenting multiple lists and discarding all scores but that of the 1 list that produced the highest score. The simulations, which model limitations inherent in the precision of word recognition scores, were done to inform clinical protocols. A secondary consideration was a derivation of 95% confidence intervals for significant changes in score from phonemic scoring of a 50-word list. The PB max simulations were conducted on a "client" with flat performance intensity functions. The client's performance was assumed to be 60% initially and 40% for a second assessment. Thousands of estimates were obtained to examine the precision of (a) single lists and (b) multiple lists using a PB max procedure. This method permitted summarizing the precision for assessing a 20% drop in performance. A single 25-word list could identify only 58.4% of the cases in which performance fell from 60% to 40%. A single 125-word list identified 99.8% of the declines correctly. Presenting 3 or 5 lists to find PB max produced an undesirable finding: an increase in the word recognition score. A 25-word list produces unacceptably low precision for making clinical decisions. This finding holds in both single and multiple 25-word lists, as in a search for PB max. A table is provided, giving estimates of 95% critical ranges for successive presentations of a 50-word list analyzed by the number of phonemes correctly identified.

  16. Boosting quantum annealer performance via sample persistence

    Science.gov (United States)

    Karimi, Hamed; Rosenberg, Gili

    2017-07-01

    We propose a novel method for reducing the number of variables in quadratic unconstrained binary optimization problems, using a quantum annealer (or any sampler) to fix the value of a large portion of the variables to values that have a high probability of being optimal. The resulting problems are usually much easier for the quantum annealer to solve, due to their being smaller and consisting of disconnected components. This approach significantly increases the success rate and number of observations of the best known energy value in samples obtained from the quantum annealer, when compared with calling the quantum annealer without using it, even when using fewer annealing cycles. Use of the method results in a considerable improvement in success metrics even for problems with high-precision couplers and biases, which are more challenging for the quantum annealer to solve. The results are further enhanced by applying the method iteratively and combining it with classical pre-processing. We present results for both Chimera graph-structured problems and embedded problems from a real-world application.

  17. Robust H2 performance for sampled-data systems

    DEFF Research Database (Denmark)

    Rank, Mike Lind

    1997-01-01

    Robust H2 performance conditions under structured uncertainty, analogous to well known methods for H∞ performance, have recently emerged in both discrete and continuous-time. This paper considers the extension into uncertain sampled-data systems, taking into account inter-sample behavior. Convex...... conditions for robust H2 performance are derived for different uncertainty sets...

  18. SPHINCS: A system for cataloguing and interpreting seabed photographs of nodules

    Digital Repository Service at National Institute of Oceanography (India)

    Sharma, R.; Kodagali, V.N.

    . There is also a provision for appending data and for performing mathe- matical calculations involving various fields defined in the structure. Examples of data processing Comparison between photographic data and grab sample data Data from a seabed...

  19. Photographic materials

    International Nuclear Information System (INIS)

    1980-01-01

    Radiographic films based on silver halides are normally handled under red or orange safelights to prevent fogging due to their sensitivity to white light. The present invention relates to ultraviolet radiation sensitive material which can be handled under virtually white light without significant fogging. A photographic, chemically sensitised silver halide emulsion is described, containing 50-100 mole % of silver chloride, the higher the silver chloride content, the lower the visible light sensitivity. The remaining silver halide, if any, is silver bromide and/or silver iodide. The silver halide grains are grown in the presence of ammonia, an excess of chloride ions and tetraazaindene growth controller. Examples illustrating the invention are given. (U.K.)

  20. Photographic materials

    International Nuclear Information System (INIS)

    Jamieson, P.B.

    1980-01-01

    Radiographic films based on silver halides are normally handled under red or orange safelights to prevent fogging due to their sensitivity to white light. The present invention relates to ultraviolet radiation sensitive material which can be handled under virtually white light without significant fogging. The film material is comprised of a base having at least one layer of a photographic silver halide emulsion and a yellow filter dye screening the emulsion from visible radiation. The silver halide emulsion contains 50-100 mole % of silver chloride, the higher the silver chloride content, the lower the visible light sensitivity. The nature and properties of the yellow filter dye are described. When recording an X-ray image, the film is loaded into the camera under white safelight conditions from which light of wavelength shorter than 400 nm is excluded. The film is in contact with one or more phosphor screens capable when struck by X-rays of emitting ultraviolet radiation, the screens having a peak ultraviolet emission within the wavelength range of 250-380 nm. After X-ray exposure, the film is removed and developed. Two examples illustrating the invention are given. (U.K.)

  1. How many tigers Panthera tigris are there in Huai Kha Khaeng Wildlife Sanctuary, Thailand? An estimate using photographic capture-recapture sampling

    Science.gov (United States)

    Simcharoen, S.; Pattanavibool, A.; Karanth, K.U.; Nichols, J.D.; Kumar, N.S.

    2007-01-01

    We used capture-recapture analyses to estimate the density of a tiger Panthera tigris population in the tropical forests of Huai Kha Khaeng Wildlife Sanctuary, Thailand, from photographic capture histories of 15 distinct individuals. The closure test results (z = 0.39, P = 0.65) provided some evidence in support of the demographic closure assumption. Fit of eight plausible closed models to the data indicated more support for model Mh, which incorporates individual heterogeneity in capture probabilities. This model generated an average capture probability $\\hat p$ = 0.42 and an abundance estimate of $\\widehat{N}(\\widehat{SE}[\\widehat{N}])$ = 19 (9.65) tigers. The sampled area of $\\widehat{A}(W)(\\widehat{SE}[\\widehat{A}(W)])$ = 477.2 (58.24) km2 yielded a density estimate of $\\widehat{D}(\\widehat{SE}[\\widehat{D}])$ = 3.98 (0.51) tigers per 100 km2. Huai Kha Khaeng Wildlife Sanctuary could therefore hold 113 tigers and the entire Western Forest Complex c. 720 tigers. Although based on field protocols that constrained us to use sub-optimal analyses, this estimated tiger density is comparable to tiger densities in Indian reserves that support moderate prey abundances. However, tiger densities in well-protected Indian reserves with high prey abundances are three times higher. If given adequate protection we believe that the Western Forest Complex of Thailand could potentially harbour >2,000 wild tigers, highlighting its importance for global tiger conservation. The monitoring approaches we recommend here would be useful for managing this tiger population.

  2. Performance of an active well coincidence counter for HEU samples

    International Nuclear Information System (INIS)

    Ferrari, Francesca; Peerani, Paolo

    2010-01-01

    Neutron coincidence counting is the reference NDA technique used in nuclear safeguards to measure the mass of nuclear material in samples. For high-enriched uranium (HEU) samples active neutron interrogation is generally performed and the most common device used by nuclear inspectors is the Active Well Coincidence Counter (AWCC). Within her master thesis at the Polytechnic of Milan, the first author performed an intensive study on the characteristics and performances of the AWCC in order to assess the 235 U mass in HEU oxide samples at the PERLA laboratory of JRC. The work has been summarised in this paper that starts with the optimisation of the use of AWCC for nuclear safeguards, describing the calibration procedure, reporting results of a series of verification measurements, summarising the performances that can be obtained with this instruments during inspections at fuel production plants and concluding with the discussion of uncertainties related to these measurements.

  3. Precision of a photogrammetric method to perform 3D wound measurements compared to standard 2D photographic techniques in the horse.

    Science.gov (United States)

    Labens, R; Blikslager, A

    2013-01-01

    Methods of 3D wound imaging in man play an important role in monitoring of healing and determination of the prognosis. Standard photographic assessments in equine wound management consist of 2D analyses, which provide little quantitative information on the wound bed. 3D imaging of equine wounds is feasible using principles of stereophotogrammetry. 3D measurements differ significantly and are more precise than results with standard 2D assessments. Repeated specialised photographic imaging of 4 clinical wounds left to heal by second intention was performed. The intraoperator variability in measurements due to imaging and 3D processing was compared to that of a standard 2D technique using descriptive statistics and multivariate repeated measures ANOVA. Using a custom made imaging system, 3D analyses were successfully performed. Area and circumference measurements were significantly different between imaging modalities. The intraoperator variability of 3D measurements was up to 2.8 times less than that of 2D results. On average, the maximum discrepancy between repeated measurements was 5.8% of the mean for 3D and 17.3% of the mean for 2D assessments. The intraoperator repeatability of 3D wound measurements based on principles of stereophotogrammetry is significantly increased compared to that of a standard 2D photographic technique indicating it may be a useful diagnostic and monitoring tool. The equine granulation bed plays an important role in equine wound healing. When compared to 2D analyses 3D monitoring of the equine wound bed allows superior quantitative characterisation, contributing to clinical and experimental investigations by offering potential new parameters. © 2012 EVJ Ltd.

  4. Hydrazine Determination in Sludge Samples by High Performance Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    G. Elias; G. A. Park

    2006-02-01

    A high-performance liquid chromatographic method using ultraviolet (UV) detection was developed to detect and quantify hydrazine in a variety of environmental matrices. The method was developed primarily for sludge samples, but it is also applicable to soil and water samples. The hydrazine in the matrices was derivatized to their hydrazones with benzaldehyde. The derivatized hydrazones were separated using high performance liquid chromatography (HPLC) with a reversed-phase C-18 column in an isocratic mode with methanol-water (95:5, v/v), and detected with UV detection at 313 nm. The detection limit (25 ml) for the new analytical method is 0.0067 mg ml-1of hydrazine. Hydrazine showed low recovery in soil samples because components in soil oxidized hydrazine. Sludge samples that contained relatively high soil content also showed lower recovery. The technique is relatively simple and cost-effective, and is applicable for hydrazine analysis in different environmental matrices.

  5. Sampling Efficiency and Performance of Selected Thoracic Aerosol Samplers.

    Science.gov (United States)

    Görner, Peter; Simon, Xavier; Boivin, Alexis; Bau, Sébastien

    2017-08-01

    Measurement of worker exposure to a thoracic health-related aerosol fraction is necessary in a number of occupational situations. This is the case of workplaces with atmospheres polluted by fibrous particles, such as cotton dust or asbestos, and by particles inducing irritation or bronchoconstriction such as acid mists or flour dust. Three personal and two static thoracic aerosol samplers were tested under laboratory conditions. Sampling efficiency with respect to particle aerodynamic diameter was measured in a horizontal low wind tunnel and in a vertical calm air chamber. Sampling performance was evaluated against conventional thoracic penetration. Three of the tested samplers performed well, when sampling the thoracic aerosol at nominal flow rate and two others performed well at optimized flow rate. The limit of flow rate optimization was found when using cyclone samplers. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  6. Glacier Photograph Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Glacier Photograph Collection is a database of photographs of glaciers from around the world, some dating back to the mid-1850's, that provide an historical...

  7. Sampling Approaches for Multi-Domain Internet Performance Measurement Infrastructures

    Energy Technology Data Exchange (ETDEWEB)

    Calyam, Prasad

    2014-09-15

    The next-generation of high-performance networks being developed in DOE communities are critical for supporting current and emerging data-intensive science applications. The goal of this project is to investigate multi-domain network status sampling techniques and tools to measure/analyze performance, and thereby provide “network awareness” to end-users and network operators in DOE communities. We leverage the infrastructure and datasets available through perfSONAR, which is a multi-domain measurement framework that has been widely deployed in high-performance computing and networking communities; the DOE community is a core developer and the largest adopter of perfSONAR. Our investigations include development of semantic scheduling algorithms, measurement federation policies, and tools to sample multi-domain and multi-layer network status within perfSONAR deployments. We validate our algorithms and policies with end-to-end measurement analysis tools for various monitoring objectives such as network weather forecasting, anomaly detection, and fault-diagnosis. In addition, we develop a multi-domain architecture for an enterprise-specific perfSONAR deployment that can implement monitoring-objective based sampling and that adheres to any domain-specific measurement policies.

  8. ACS sampling system: design, implementation, and performance evaluation

    Science.gov (United States)

    Di Marcantonio, Paolo; Cirami, Roberto; Chiozzi, Gianluca

    2004-09-01

    By means of ACS (ALMA Common Software) framework we designed and implemented a sampling system which allows sampling of every Characteristic Component Property with a specific, user-defined, sustained frequency limited only by the hardware. Collected data are sent to various clients (one or more Java plotting widgets, a dedicated GUI or a COTS application) using the ACS/CORBA Notification Channel. The data transport is optimized: samples are cached locally and sent in packets with a lower and user-defined frequency to keep network load under control. Simultaneous sampling of the Properties of different Components is also possible. Together with the design and implementation issues we present the performance of the sampling system evaluated on two different platforms: on a VME based system using VxWorks RTOS (currently adopted by ALMA) and on a PC/104+ embedded platform using Red Hat 9 Linux operating system. The PC/104+ solution offers, as an alternative, a low cost PC compatible hardware environment with free and open operating system.

  9. A Photographer From Ankara: Osman Darcan

    Directory of Open Access Journals (Sweden)

    Gülseren Mungan Yavuztürk

    2015-12-01

    Full Text Available This work introduces Osman Darcan, an important name in the history of Ankara photography studios. Darcan followed in the footsteps of famous Austrian photographer Othmar Pferschy, whom he met in Istanbul, to go on to create his own valuable work. On leaving the Public Press Authority Photo Film Center, where he worked as a newsreel photographer and film operator, in 1943 he began taking photographs at the Tatbikat Theater at the Ankara State Conservatoire, where he continued as the photographer for the State Theater until the end of his life. At the same time, this master photographer took the pictures of a select coterie of Ankara’s leading individuals and well-known performers at a studio he opened on Anafartalar Caddesi. In both these roles, his photographs evoke admiration thanks to Darcan’s professional abilities and level of artistry.

  10. Effect of sample size on bias correction performance

    Science.gov (United States)

    Reiter, Philipp; Gutjahr, Oliver; Schefczyk, Lukas; Heinemann, Günther; Casper, Markus C.

    2014-05-01

    The output of climate models often shows a bias when compared to observed data, so that a preprocessing is necessary before using it as climate forcing in impact modeling (e.g. hydrology, species distribution). A common bias correction method is the quantile matching approach, which adapts the cumulative distribution function of the model output to the one of the observed data by means of a transfer function. Especially for precipitation we expect the bias correction performance to strongly depend on sample size, i.e. the length of the period used for calibration of the transfer function. We carry out experiments using the precipitation output of ten regional climate model (RCM) hindcast runs from the EU-ENSEMBLES project and the E-OBS observational dataset for the period 1961 to 2000. The 40 years are split into a 30 year calibration period and a 10 year validation period. In the first step, for each RCM transfer functions are set up cell-by-cell, using the complete 30 year calibration period. The derived transfer functions are applied to the validation period of the respective RCM precipitation output and the mean absolute errors in reference to the observational dataset are calculated. These values are treated as "best fit" for the respective RCM. In the next step, this procedure is redone using subperiods out of the 30 year calibration period. The lengths of these subperiods are reduced from 29 years down to a minimum of 1 year, only considering subperiods of consecutive years. This leads to an increasing number of repetitions for smaller sample sizes (e.g. 2 for a length of 29 years). In the last step, the mean absolute errors are statistically tested against the "best fit" of the respective RCM to compare the performances. In order to analyze if the intensity of the effect of sample size depends on the chosen correction method, four variations of the quantile matching approach (PTF, QUANT/eQM, gQM, GQM) are applied in this study. The experiments are further

  11. The Performance Analysis Based on SAR Sample Covariance Matrix

    Directory of Open Access Journals (Sweden)

    Esra Erten

    2012-03-01

    Full Text Available Multi-channel systems appear in several fields of application in science. In the Synthetic Aperture Radar (SAR context, multi-channel systems may refer to different domains, as multi-polarization, multi-interferometric or multi-temporal data, or even a combination of them. Due to the inherent speckle phenomenon present in SAR images, the statistical description of the data is almost mandatory for its utilization. The complex images acquired over natural media present in general zero-mean circular Gaussian characteristics. In this case, second order statistics as the multi-channel covariance matrix fully describe the data. For practical situations however, the covariance matrix has to be estimated using a limited number of samples, and this sample covariance matrix follow the complex Wishart distribution. In this context, the eigendecomposition of the multi-channel covariance matrix has been shown in different areas of high relevance regarding the physical properties of the imaged scene. Specifically, the maximum eigenvalue of the covariance matrix has been frequently used in different applications as target or change detection, estimation of the dominant scattering mechanism in polarimetric data, moving target indication, etc. In this paper, the statistical behavior of the maximum eigenvalue derived from the eigendecomposition of the sample multi-channel covariance matrix in terms of multi-channel SAR images is simplified for SAR community. Validation is performed against simulated data and examples of estimation and detection problems using the analytical expressions are as well given.

  12. Determining the Particle Size of Debris from a Tunnel Boring Machine Through Photographic Analysis and Comparison Between Excavation Performance and Rock Mass Properties

    Science.gov (United States)

    Rispoli, A.; Ferrero, A. M.; Cardu, M.; Farinetti, A.

    2017-10-01

    This paper presents the results of a study carried out on a 6.3-m-diameter exploratory tunnel excavated in hard rock by an open tunnel boring machine (TBM). The study provides a methodology, based on photographic analysis, for the evaluation of the particle size distribution of debris produced by the TBM. A number of tests were carried out on the debris collected during the TBM advancement. In order to produce a parameter indicative of the particle size of the debris, the coarseness index (CI) was defined and compared with some parameters representative of the TBM performance [i.e. the excavation specific energy (SE) and field penetration index (FPI)] and rock mass features, such as RMR, GSI, uniaxial compression strength and joint spacing. The results obtained showed a clear trend between the CI and some TBM performance parameters, such as SE and FPI. On the contrary, due to the rock mass fracturing, a clear relationship between the CI and rock mass characteristics was not found.

  13. Personnel photographic film dosimetry

    International Nuclear Information System (INIS)

    Keirim-Markus, I.B.

    1981-01-01

    Technology of personnel photographic film dosimetry (PPD) based on the photographic effect of ionizing radiation is described briefly. Kinds of roentgen films used in PPD method are enumerated, compositions of a developer and fixing agents for these films are given [ru

  14. Agreement in the diagnosis of dental fluorosis in central incisors performed by a standardized photographic method and clinical examination Concordância no diagnóstico da fluorose dentária em incisivos centrais realizado por um método fotográfico padronizado e pelo exame clínico

    OpenAIRE

    Carolina Castro Martins; Loliza Chalub; Ynara Bosco Lima-Arsati; Isabela Almeida Pordeus; Saul Martins Paiva

    2009-01-01

    The aim of this study was to assess agreement in the diagnosis of dental fluorosis performed by a standardized digital photographic method and a clinical examination (gold standard). 49 children (aged 7-9 years) were clinically evaluated by a trained examiner for the assessment of dental fluorosis. Central incisors were evaluated for the presence or absence of dental fluorosis and were photographed with a digital camera. Photographs were presented to three pediatric dentists, who examined the...

  15. [Natural head position's reproducibility on photographs].

    Science.gov (United States)

    Eddo, Marie-Line; El Hayeck, Émilie; Hoyeck, Maha; Khoury, Élie; Ghoubril, Joseph

    2017-12-01

    The purpose of this study is to evaluate the reproducibility of natural head position with time on profile photographs. Our sample is composed of 96 students (20-30 years old) at the department of dentistry of Saint Joseph University in Beirut. Two profile photographs were taken in natural head position about a week apart. No significant differences were found between T0 and T1 (E = 1.065°). Many studies confirmed this reproducibility with time. Natural head position can be adopted as an orientation for profile photographs in orthodontics. © EDP Sciences, SFODF, 2017.

  16. Performance test of SAUNA xenon mobile sampling system

    International Nuclear Information System (INIS)

    Hu Dan; Yang Bin; Yang Weigeng; Jia Huaimao; Wang Shilian; Li Qi; Zhao Yungang; Fan Yuanqing; Chen Zhanying; Chang Yinzhong; Liu Shujiang; Zhang Xinjun; Wang Jun

    2011-01-01

    In this article, the structure and basic functions of SAUNA noble gas xenon mobile sampling system are introduced. The sampling capability of this system is about 2.2 mL per day, as a result from a 684-h operation. The system can be transported to designated locations conveniently to collect xenon sample for routine or emergency environment monitoring. (authors)

  17. Sample preparation of environmental samples using benzene synthesis followed by high-performance LSC

    International Nuclear Information System (INIS)

    Filippis, S. De; Noakes, J.E.

    1991-01-01

    Liquid scintillation counting (LSC) techniques have been widely employed as the detection method for determining environmental levels of tritium and 14 C. Since anthropogenic and nonanthropogenic inputs to the environment are a concern, sampling the environment surrounding a nuclear power facility or fuel reprocessing operation requires the collection of many different sample types, including agriculture products, water, biota, aquatic life, soil, and vegetation. These sample types are not suitable for the direct detection of tritium of 14 C for liquid scintillation techniques. Each sample type must be initially prepared in order to obtain the carbon or hydrogen component of interest and present this in a chemical form that is compatible with common chemicals used in scintillation counting applications. Converting the sample of interest to chemically pure benzene as a sample preparation technique has been widely accepted for processing samples for radiocarbon age-dating applications. The synthesized benzene is composed of the carbon or hydrogen atoms from the original sample and is ideal as a solvent for LSC with excellent photo-optical properties. Benzene synthesis followed by low-background scintillation counting can be applied to the preparation and measurement of environmental samples yielding good detection sensitivities, high radionuclide counting efficiency, and shorter preparation time. The method of benzene synthesis provides a unique approach to the preparation of a wide variety of environmental sample types using similar chemistry for all samples

  18. Evaluation of common methods for sampling invertebrate pollinator assemblages: net sampling out-perform pan traps.

    Directory of Open Access Journals (Sweden)

    Tony J Popic

    Full Text Available Methods for sampling ecological assemblages strive to be efficient, repeatable, and representative. Unknowingly, common methods may be limited in terms of revealing species function and so of less value for comparative studies. The global decline in pollination services has stimulated surveys of flower-visiting invertebrates, using pan traps and net sampling. We explore the relative merits of these two methods in terms of species discovery, quantifying abundance, function, and composition, and responses of species to changing floral resources. Using a spatially-nested design we sampled across a 5000 km(2 area of arid grasslands, including 432 hours of net sampling and 1296 pan trap-days, between June 2010 and July 2011. Net sampling yielded 22% more species and 30% higher abundance than pan traps, and better reflected the spatio-temporal variation of floral resources. Species composition differed significantly between methods; from 436 total species, 25% were sampled by both methods, 50% only by nets, and the remaining 25% only by pans. Apart from being less comprehensive, if pan traps do not sample flower-visitors, the link to pollination is questionable. By contrast, net sampling functionally linked species to pollination through behavioural observations of flower-visitation interaction frequency. Netted specimens are also necessary for evidence of pollen transport. Benefits of net-based sampling outweighed minor differences in overall sampling effort. As pan traps and net sampling methods are not equivalent for sampling invertebrate-flower interactions, we recommend net sampling of invertebrate pollinator assemblages, especially if datasets are intended to document declines in pollination and guide measures to retain this important ecosystem service.

  19. Evaluation of common methods for sampling invertebrate pollinator assemblages: net sampling out-perform pan traps.

    Science.gov (United States)

    Popic, Tony J; Davila, Yvonne C; Wardle, Glenda M

    2013-01-01

    Methods for sampling ecological assemblages strive to be efficient, repeatable, and representative. Unknowingly, common methods may be limited in terms of revealing species function and so of less value for comparative studies. The global decline in pollination services has stimulated surveys of flower-visiting invertebrates, using pan traps and net sampling. We explore the relative merits of these two methods in terms of species discovery, quantifying abundance, function, and composition, and responses of species to changing floral resources. Using a spatially-nested design we sampled across a 5000 km(2) area of arid grasslands, including 432 hours of net sampling and 1296 pan trap-days, between June 2010 and July 2011. Net sampling yielded 22% more species and 30% higher abundance than pan traps, and better reflected the spatio-temporal variation of floral resources. Species composition differed significantly between methods; from 436 total species, 25% were sampled by both methods, 50% only by nets, and the remaining 25% only by pans. Apart from being less comprehensive, if pan traps do not sample flower-visitors, the link to pollination is questionable. By contrast, net sampling functionally linked species to pollination through behavioural observations of flower-visitation interaction frequency. Netted specimens are also necessary for evidence of pollen transport. Benefits of net-based sampling outweighed minor differences in overall sampling effort. As pan traps and net sampling methods are not equivalent for sampling invertebrate-flower interactions, we recommend net sampling of invertebrate pollinator assemblages, especially if datasets are intended to document declines in pollination and guide measures to retain this important ecosystem service.

  20. Sequential effects in pigeon delayed matching-to-sample performance.

    Science.gov (United States)

    Roitblat, H L; Scopatz, R A

    1983-04-01

    Pigeons were tested in a three-alternative delayed matching-to-sample task in which second-choices were permitted following first-choice errors. Sequences of responses both within and between trials were examined in three experiments. The first experiment demonstrates that the sample information contained in first-choice errors is not sufficient to account for the observed pattern of second choices. This result implies that second-choices following first-choice errors are based on a second examination of the contents of working memory. Proactive interference was found in the second experiment in the form of a dependency, beyond that expected on the basis of trial independent response bias, of first-choices from one trial on the first-choice emitted on the previous trial. Samples from the previous trial were not found to exert a significant influence on later trials. The magnitude of the intertrial association (Experiment 3) did not depend on the duration of the intertrial interval. In contrast, longer intertrial intervals and longer sample durations did facilitate choice accuracy, by strengthening the association between current samples and choices. These results are incompatible with a trace-decay and competition model; they suggest strongly that multiple influences act simultaneously and independently to control delayed matching-to-sample responding. These multiple influences include memory for the choice occurring on the previous trial, memory for the sample, and general effects of trial spacing.

  1. Hotspot and sampling analysis for effective maintenance and performance monitoring.

    Science.gov (United States)

    2017-05-01

    In this project, we propose two sampling methods addressing how much and where the agencies need to collect infrastraucture condition data for accurate Level-of-Maintenance (LOM) estimation in maintenance network with single type or multiple ty...

  2. D Photographs in Cultural Heritage

    Science.gov (United States)

    Schuhr, W.; Lee, J. D.; Kiel, St.

    2013-07-01

    This paper on providing "oo-information" (= objective object-information) on cultural monuments and sites, based on 3D photographs is also a contribution of CIPA task group 3 to the 2013 CIPA Symposium in Strasbourg. To stimulate the interest in 3D photography for scientists as well as for amateurs, 3D-Masterpieces are presented. Exemplary it is shown, due to their high documentary value ("near reality"), 3D photography support, e.g. the recording, the visualization, the interpretation, the preservation and the restoration of architectural and archaeological objects. This also includes samples for excavation documentation, 3D coordinate calculation, 3D photographs applied for virtual museum purposes and as educational tools. In addition 3D photography is used for virtual museum purposes, as well as an educational tool and for spatial structure enhancement, which in particular holds for inscriptions and in rock arts. This paper is also an invitation to participate in a systematic survey on existing international archives of 3D photographs. In this respect it is also reported on first results, to define an optimum digitization rate for analog stereo views. It is more than overdue, in addition to the access to international archives for 3D photography, the available 3D photography data should appear in a global GIS(cloud)-system, like on, e.g., google earth. This contribution also deals with exposing new 3D photographs to document monuments of importance for Cultural Heritage, including the use of 3D and single lense cameras from a 10m telescope staff, to be used for extremely low earth based airborne 3D photography, as well as for "underwater staff photography". In addition it is reported on the use of captive balloon and drone platforms for 3D photography in Cultural Heritage. It is liked to emphasize, the still underestimated 3D effect on real objects even allows, e.g., the spatial perception of extremely small scratches as well as of nuances in color differences

  3. The effect of sample preparation methods on glass performance

    International Nuclear Information System (INIS)

    Oh, M.S.; Oversby, V.M.

    1990-01-01

    A series of experiments was conducted using SRL 165 synthetic waste glass to investigate the effects of surface preparation and leaching solution composition on the alteration of the glass. Samples of glass with as-cast surfaces produced smooth reaction layers and some evidence for precipitation of secondary phases from solution. Secondary phases were more abundant in samples reacted in deionized water than for those reacted in a silicate solution. Samples with saw-cut surfaces showed a large reduction in surface roughness after 7 days of reaction in either solution. Reaction in silicate solution for up to 91 days produced no further change in surface morphology, while reaction in DIW produced a spongy surface that formed the substrate for further surface layer development. The differences in the surface morphology of the samples may create microclimates that control the details of development of alteration layers on the glass; however, the concentrations of elements in leaching solutions show differences of 50% or less between samples prepared with different surface conditions for tests of a few months duration. 6 refs., 7 figs., 1 tab

  4. Performance evaluation of communication systems via importance sampling

    NARCIS (Netherlands)

    Remondo Bueno, D.

    2000-01-01

    In the design and development of telecommunication systems, the preparation of experiments can be made more effective by predicting the system performance and its dependence on the different system parameters. This can be done by modeling the system and using performance evaluation methods. This

  5. Performance of sampling methods to estimate log characteristics for wildlife.

    Science.gov (United States)

    Lisa J. Bate; Torolf R. Torgersen; Michael J. Wisdom; Edward O. Garton

    2004-01-01

    Accurate estimation of the characteristics of log resources, or coarse woody debris (CWD), is critical to effective management of wildlife and other forest resources. Despite the importance of logs as wildlife habitat, methods for sampling logs have traditionally focused on silvicultural and fire applications. These applications have emphasized estimates of log volume...

  6. Electro photographic materials

    International Nuclear Information System (INIS)

    Buzdugan, A.; Andries, A.; Iovu, M.

    2000-01-01

    The invention relates to the creation of electro photographic materials . The invention allows to extend the material photosensitivity into the infrared range of the spectrum. An electro photographic materials contains an electro conducting base, including a dielectric base 1, for example glass, an electro conducting layer 2, for example of Al, Ni, Cr, an injecting layer 3, consisting of amorphous indium phosphide, a vitreous layer 4 of the arsenic sulphide - antimony sulphide system and a transporting layer 5 of the arsenic sulphide or arsenic selenide

  7. Reproductive performance in a select sample of dairy herds.

    Science.gov (United States)

    Ferguson, James D; Skidmore, Andrew

    2013-02-01

    Sixteen herds were selected from a pool of 64 herds nominated by consultants for participation in a national survey to demonstrate excellence in reproductive performance. For inclusion in the survey, herds had to have comprehensive records in a farm computer database or participate in a Dairy Herd Improvement Association record system and have superior reproductive performance as judged by the herd advisor. Herd managers were asked to fill out a questionnaire to describe their reproductive management practices and provide herd records for data analysis. Reproductive analysis was based on individual cow records for active and cull dairy cows that calved during the calendar year 2010. Breeding records by cow were used to calculate indices for insemination rate (IR), conception rate (CR), pregnancy rate (PR), and culling. Herds ranged in size from 262 to 6,126 lactating and dry cows, with a mean of 1,654 [standard deviation (SD) 1,494] cows. Mean days to first insemination (DFS) was 71.2d (SD 4.7d), and IR for first insemination was 86.9%. Mean days between inseminations were 33.4d (SD 3.1d), and 15.4% of insemination intervals were greater than 48 d (range: 7.2 to 21.5%). First-service conception rate was 44.4% (SD 4.8%) across all herds and ranged from 37.5 to 51.8%. Mean PR was 32.0% (SD 3.9%) with a range of 26.5 to 39.4%. Lactation cull rate was 32.2% (SD 12.4%) with a range from 13.6 to 58.1%. Compared with mean data and SD for herds in the Raleigh Dairy Herd Improvement Association system, mean indices for these herds ranked them in the 99 th percentile for IR (using heat detection rate as comparison), 99 th percentile for PR, the bottom 18.6 percentile for DFS, and around the 50th percentile for CR. This suggests that excellent herd reproductive performance was associated with reproductive management that resulted in high insemination rates combined with average CR. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights

  8. Evaluation of photographs supporting an FFQ developed for adolescents.

    Science.gov (United States)

    Brito, Alessandra Page; Guimarães, Celso Pereira; Pereira, Rosangela Alves

    2014-01-01

    To evaluate the validity of food photographs used to support the reporting of food intake with an FFQ designed for adolescents from Rio de Janeiro, Brazil. A set of ninety-five food photographs was elaborated. The photographs' evaluation process included the acknowledgement of foods and portions in the pictures. In the identification of foods (ninety-five photographs) and typical portions (twelve photographs), the adolescents were requested to answer a structured questionnaire related to the food photographs. The identification of the portion size of amorphous foods (forty-three photographs) was performed using three different portion sizes of actual preparations. The proportions (and 95% confidence intervals) of adolescents who correctly identified foods and portion size in each photograph were estimated. A public school in Niterói, Rio de Janeiro State, Brazil. Sixty-two adolescents between 11·0 and 18·9 years old, randomly selected. At least 90% of adolescents correctly identified the food in ninety-two photographs and the food in the three remaining photographs was recognized by 80-89% of the adolescents. At least 98% of the adolescents correctly identified eleven typical or natural portions in the food photographs. For amorphous foods, at least 70% of teenagers correctly identified the portion size in the photograph of thirty-one foods; for the other photographs, the portion size was correctly recognized by 50-69% of the adolescents for eight foods and by less than 50% of adolescents for four foods. The analysed photographs are appropriate visual aids to the reporting of food consumption by adolescents.

  9. Does Taking Photographs Help?

    Science.gov (United States)

    Hand, Sarah

    2010-01-01

    Since many people tend to use photographs as memory anchors, this author decided she wanted to know whether the process of capturing and manipulating an image taken during a learning activity would act as a memory anchor for children's visual, auditory and kinaesthetic memories linked to their cognitive learning at the time. In plain English,…

  10. Geotagging Photographs in Student Fieldwork

    Science.gov (United States)

    Welsh, Katharine E.; France, Derek; Whalley, W. Brian; Park, Julian R.

    2012-01-01

    This resource paper provides guidance for staff and students on the potential educational benefits, limitations and applications of geotagging photographs. It also offers practical advice for geotagging photographs in a range of fieldwork settings and reviews three free smartphone applications (apps) for geotagging photographs (Flickr, Evernote…

  11. Preferences for photographic art among hospitalized patients with cancer.

    Science.gov (United States)

    Hanson, Hazel; Schroeter, Kathryn; Hanson, Andrew; Asmus, Kathryn; Grossman, Azure

    2013-07-01

    To determine the preferences of patients with cancer for viewing photographic art in an inpatient hospital setting and to evaluate the impact of viewing photographic art. Quantitative, exploratory, single-group, post-test descriptive design incorporating qualitative survey questions. An academic medical center in the midwestern United States. 80 men (n = 44) and women (n = 36) aged 19-85 years (X = 49) and hospitalized for cancer treatment. Participants viewed photographs via computers and then completed a five-instrument electronic survey. Fatigue, quality of life, performance status, perceptions of distraction and restoration, and content categories of photographs. Ninety-six percent of participants enjoyed looking at the study photographs. The photographs they preferred most often were lake sunset (76%), rocky river (66%), and autumn waterfall (66%). The most rejected photographs were amusement park (54%), farmer's market vegetable table (51%), and kayakers (49%). The qualitative categories selected were landscape (28%), animals (15%), people (14%), entertainment (10%), imagery (10%), water (7%), spiritual (7%), flowers (6%), and landmark (3%). Some discrepancy between the quantitative and qualitative sections may be related to participants considering water to be a landscape. The hypothesis that patients' preferences for a category of photographic art are affected by the psychophysical and psychological qualities of the photographs, as well as the patients' moods and characteristics, was supported. Nurses can play an active role in helping patients deal with the challenges of long hospital stays and life-threatening diagnoses through distraction and restoration interventions such as viewing photographic images of nature. Nurses can use photographic imagery to provide a restorative intervention during the hospital experience. Photographic art can be used as a distraction from the hospital stay and the uncertainty of a cancer diagnosis. Having patients view

  12. Photograph of the Month

    Science.gov (United States)

    2015-04-01

    For dykes, magma flow direction can be deciphered from various fabrics in the chilled margin (Correa-Gomez et al., 2001, JSG 23, 1415). This photograph represents part of a chilled margin of a appr. N- S trending dyke at Kharghar Hills, Mumbai, Maharashtra, India. The section is sub-vertical. The elongated grooves indicate flow of magma through a fault and the tapered grooves (arrows) connote the flow direction: towards the pointed end of the groove. The magma flowed towards the north in this case. Such fabrics of wall-magma interaction in the Deccan volcanic province prove that dykes injected along fault planes. 19° 2‧ 22.3″ N, 73° 3‧ 28.7″ E. Photograph Ayan Achyuta Misra, Mumbai, India.

  13. Computer aided photographic engineering

    Science.gov (United States)

    Hixson, Jeffrey A.; Rieckhoff, Tom

    1988-01-01

    High speed photography is an excellent source of engineering data but only provides a two-dimensional representation of a three-dimensional event. Multiple cameras can be used to provide data for the third dimension but camera locations are not always available. A solution to this problem is to overlay three-dimensional CAD/CAM models of the hardware being tested onto a film or photographic image, allowing the engineer to measure surface distances, relative motions between components, and surface variations.

  14. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  15. Organisation of a laboratory of photographic dosimetry

    International Nuclear Information System (INIS)

    Soudain, Georges

    1961-01-01

    After a recall of the main properties of photographic dosimetry, the author describes the principle of this method, and comments the issue of chromatic sensitivity of photographic emulsions. He discusses the calibration process for gamma radiation, X rays, and thermal neutrons. He describes how fast neutron dosimetry is performed. In the next part, he describes the organisation of the photometry laboratory which has to prepare and distribute dosimeters, to collect and exploit them, and to prepare a publication of results. These different missions and tasks are described

  16. Food photographs in nutritional surveillance: errors in portion size estimation using drawings of bread and photographs of margarine and beverages consumption.

    Science.gov (United States)

    De Keyzer, Willem; Huybrechts, Inge; De Maeyer, Mieke; Ocké, Marga; Slimani, Nadia; van 't Veer, Pieter; De Henauw, Stefaan

    2011-04-01

    Food photographs are widely used as instruments to estimate portion sizes of consumed foods. Several food atlases are available, all developed to be used in a specific context and for a given study population. Frequently, food photographs are adopted for use in other studies with a different context or another study population. In the present study, errors in portion size estimation of bread, margarine on bread and beverages by two-dimensional models used in the context of a Belgian food consumption survey are investigated. A sample of 111 men and women (age 45-65 years) were invited for breakfast; two test groups were created. One group was asked to estimate portion sizes of consumed foods using photographs 1-2 d after consumption, and a second group was asked the same after 4 d. Also, real-time assessment of portion sizes using photographs was performed. At the group level, large overestimation of margarine, acceptable underestimation of bread and only small estimation errors for beverages were found. Women tended to have smaller estimation errors for bread and margarine compared with men, while the opposite was found for beverages. Surprisingly, no major difference in estimation error was found after 4 d compared with 1-2 d. Individual estimation errors were large for all foods. The results from the present study suggest that the use of food photographs for portion size estimation of bread and beverages is acceptable for use in nutrition surveys. For photographs of margarine on bread, further validation using smaller amounts corresponding to actual consumption is recommended.

  17. The Life of Digital Photographs

    DEFF Research Database (Denmark)

    Larsen, Jonas

    )mobilities of things, practice approaches to photography and multi sited ethnography, this talk discusses and empirically track the life (the conception, birth, transformative years, ageing and death) travel, detours, makeovers and destinations of (analogue and digital) photographs in our present network societies. So...... we can understand the life of more-than representational photographs, and then I turn to my ethnographies to flesh out empirically the life of tourist photographs...

  18. Photographic Portraits: Narrative and Memory

    Directory of Open Access Journals (Sweden)

    Brian Roberts

    2011-05-01

    Full Text Available This article is a more general "companion" to the subsequent, Brian ROBERTS (2011 "Interpreting Photographic Portraits: Autobiography, Time Perspectives and Two School Photographs". The article seeks to add to the growing awareness of the importance of visual materials and methods in qualitative social research and to give an introduction to the "photographic self image"—self-portraits and portraits. It focuses on time and memory, including the experiential associations (in consciousness and the senses that the self engenders, thus linking the "visual" (photographic and "auto/biographical". The article attempts to "map" a field—the use of portraiture within social science—drawing on narrative and biographical research, on one side, and photographic portraiture, on the other. In supporting the use of photography in qualitative research it points to the need for researchers to have a greater knowledge of photographic (and art criticism and cognisance of photographic practices. The article does not intend to give a definitive account of photographic portraiture or prescribe in detail how it may be used within social science. It is an initial overview of the development and issues within the area of photographic portraiture and an exploration of relevant methodological issues when images of individuals are employed within social science—so that "portraiture" is better understood and developed within biographical and narrative research. URN: http://nbn-resolving.de/urn:nbn:de:0114-fqs110263

  19. Performance of local information-based link prediction: a sampling perspective

    Science.gov (United States)

    Zhao, Jichang; Feng, Xu; Dong, Li; Liang, Xiao; Xu, Ke

    2012-08-01

    Link prediction is pervasively employed to uncover the missing links in the snapshots of real-world networks, which are usually obtained through different kinds of sampling methods. In the previous literature, in order to evaluate the performance of the prediction, known edges in the sampled snapshot are divided into the training set and the probe set randomly, without considering the underlying sampling approaches. However, different sampling methods might lead to different missing links, especially for the biased ways. For this reason, random partition-based evaluation of performance is no longer convincing if we take the sampling method into account. In this paper, we try to re-evaluate the performance of local information-based link predictions through sampling method governed division of the training set and the probe set. It is interesting that we find that for different sampling methods, each prediction approach performs unevenly. Moreover, most of these predictions perform weakly when the sampling method is biased, which indicates that the performance of these methods might have been overestimated in the prior works.

  20. Method of making stepped photographic density standards of radiographic photographs

    International Nuclear Information System (INIS)

    Borovin, I.V.; Kondina, M.A.

    1987-01-01

    In industrial radiography practice the need often arises for a prompt evaluation of the photographic density of an x-ray film. A method of making stepped photographic density standards for industrial radiography by contact printing from a negative is described. The method is intended for industrial radiation flaw detection laboratories not having specialized sensitometric equipment

  1. The Social Effects of War Photographs

    Directory of Open Access Journals (Sweden)

    Gökhan DEMİREL

    2017-07-01

    Full Text Available In today’s world, knowledge is increasingly impacted via visual representation. The messages sent through various sources, such as newspaper, television and the internet, lead people to form opinions about various topics. In this context, photography is one of the most powerful source of information. Moreover, the visual power and the ability to show nonverbal communication makes it a perfect tool for propaganda. These days, photographs showing war themes are used more often than the past. It can be said that war photographs serve as a tool for showing the world the realities of war to those, even to those who turn their back to massacres. After all, a dead body creates a shocking effect in the seer. In this study, the context of the photographs of the war, examined in sample of photograph of Aylan Kurdi, which became the “icon” of immigration due to Syrian civil war and war it relates to and it is studied to understand how it is assessed and understood considering the environment and conditions on the date the photo was taken, existing values, beliefs and things happened in the world in that time, from a critical point of view.

  2. Test plan for evaluating the performance of the in-tank fluidic sampling system

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    The PHMC will provide Low Activity Wastes (LAW) tank wastes for final treatment by a privatization contractor from double-shell feed tanks, 241-AP-102 and 241-AP-104, Concerns about the inability of the baseline ''grab'' sampling to provide large volume samples within time constraints has led to the development of a conceptual sampling system that would be deployed in a feed tank riser, This sampling system will provide large volume, representative samples without the environmental, radiation exposure, and sample volume impacts of the current base-line ''grab'' sampling method. This test plan identifies ''proof-of-principle'' cold tests for the conceptual sampling system using simulant materials. The need for additional testing was identified as a result of completing tests described in the revision test plan document, Revision 1 outlines tests that will evaluate the performance and ability to provide samples that are representative of a tanks' content within a 95 percent confidence interval, to recovery from plugging, to sample supernatant wastes with over 25 wt% solids content, and to evaluate the impact of sampling at different heights within the feed tank. The test plan also identifies operating parameters that will optimize the performance of the sampling system

  3. A new unbiased stochastic derivative estimator for discontinuous sample performances with structural parameters

    NARCIS (Netherlands)

    Peng, Yijie; Fu, Michael C.; Hu, Jian Qiang; Heidergott, Bernd

    In this paper, we propose a new unbiased stochastic derivative estimator in a framework that can handle discontinuous sample performances with structural parameters. This work extends the three most popular unbiased stochastic derivative estimators: (1) infinitesimal perturbation analysis (IPA), (2)

  4. Performance Comparison of Reconstruction Algorithms in Discrete Blind Multi-Coset Sampling

    DEFF Research Database (Denmark)

    Grigoryan, Ruben; Arildsen, Thomas; Tandur, Deepaknath

    2012-01-01

    This paper investigates the performance of different reconstruction algorithms in discrete blind multi-coset sampling. Multi-coset scheme is a promising compressed sensing architecture that can replace traditional Nyquist-rate sampling in the applications with multi-band frequency sparse signals...

  5. Sensor performance as a function of sampling (d) and optical blur (Fλ)

    NARCIS (Netherlands)

    Bijl, P.; Hogervorst, M.A.

    2009-01-01

    Detector sampling and optical blur are two major factors affecting Target Acquisition (TA) performance with modern EO and IR systems. In order to quantify their relative significance, we simulated five realistic LWIR and MWIR sensors from very under-sampled (detector pitch d >> diffraction blur Fλ)

  6. Model Complexity and Out-of-Sample Performance: Evidence from S&P 500 Index Returns

    NARCIS (Netherlands)

    Kaeck, Andreas; Rodrigues, Paulo; Seeger, Norman J.

    We apply a range of out-of-sample specification tests to more than forty competing stochastic volatility models to address how model complexity affects out-of-sample performance. Using daily S&P 500 index returns, model confidence set estimations provide strong evidence that the most important model

  7. Experimental performance evaluation of two stack sampling systems in a plutonium facility

    International Nuclear Information System (INIS)

    Glissmeyer, J.A.

    1992-04-01

    The evaluation of two routine stack sampling systems at the Z-Plant plutonium facility operated by Rockwell International for USERDA is part of a larger study, sponsored by Rockwell and conducted by Battelle, Pacific Northwest Laboratories, of gaseous effluent sampling systems. The gaseous effluent sampling systems evaluated are located at the main plant ventilation stack (291-Z-1) and at a vessel vent stack (296-Z-3). A preliminary report, which was a paper study issued in April 1976, identified many deficiencies in the existing sampling systems and made recommendations for corrective action. The objectives of this experimental evaluation of those sampling systems were as follows: Characterize the radioactive aerosols in the stack effluents; Develop a tracer aerosol technique for validating particulate effluent sampling system performance; Evaluate the performance of the existing routine sampling systems and their compliance with the sponsor's criteria; and Recommend corrective action where required. The tracer aerosol approach to sampler evaluation was chosen because the low concentrations of radioactive particulates in the effluents would otherwise require much longer sampling times and thus more time to complete this evaluation. The following report describes the sampling systems that are the subject of this study and then details the experiments performed. The results are then presented and discussed. Much of the raw and finished data are included in the appendices

  8. Breaking Free of Sample Size Dogma to Perform Innovative Translational Research

    Science.gov (United States)

    Bacchetti, Peter; Deeks, Steven G.; McCune, Joseph M.

    2011-01-01

    Innovative clinical and translational research is often delayed or prevented by reviewers’ expectations that any study performed in humans must be shown in advance to have high statistical power. This supposed requirement is not justifiable and is contradicted by the reality that increasing sample size produces diminishing marginal returns. Studies of new ideas often must start small (sometimes even with an N of 1) because of cost and feasibility concerns, and recent statistical work shows that small sample sizes for such research can produce more projected scientific value per dollar spent than larger sample sizes. Renouncing false dogma about sample size would remove a serious barrier to innovation and translation. PMID:21677197

  9. "Photographing money" task pricing

    Science.gov (United States)

    Jia, Zhongxiang

    2018-05-01

    "Photographing money" [1]is a self-service model under the mobile Internet. The task pricing is reasonable, related to the success of the commodity inspection. First of all, we analyzed the position of the mission and the membership, and introduced the factor of membership density, considering the influence of the number of members around the mission on the pricing. Multivariate regression of task location and membership density using MATLAB to establish the mathematical model of task pricing. At the same time, we can see from the life experience that membership reputation and the intensity of the task will also affect the pricing, and the data of the task success point is more reliable. Therefore, the successful point of the task is selected, and its reputation, task density, membership density and Multiple regression of task positions, according to which a nhew task pricing program. Finally, an objective evaluation is given of the advantages and disadvantages of the established model and solution method, and the improved method is pointed out.

  10. Sensory evaluation of meat colour using photographs

    Directory of Open Access Journals (Sweden)

    Gianluigi Destefanis

    2010-01-01

    Full Text Available Five m. longissimus thoracis steaks from different breeds, purchased at retail, were cut into samples and simultaneously photographed under standard shooting conditions. The first photo was taken on samples just arrived at the laboratory, the second one on a freshly cut surface after blooming. Two consumer panels evaluated beef colour using respectively photo 1 and photo 2. Each consumer was asked to rank samples in order of preference. Rank sums were evaluated with Fridman’s test. Immediately after taking the photos, colour was measured with a colorimeter. Regarding photo 1, consumers were able to discriminate one sample, the worst, from all the others. Concerning photo 2, consumers discriminated the worst sample, as in photo 1, but also the best one. Therefore a more accurate colour evaluation can be obtained if the assessment is carried out on a fresh cut surface after blooming. In general consumers preferred samples with high lightness and a relatively high yellowness. The sensory evaluation of meat colour using photographs is a promising tool to overcome the difficulties when the meat is directly evaluated. But it is very important to standardize the shooting conditions to obtain a true reproduction of the meat. For this purpose the use of a colour target is useful to check the validity of the adopted parameters.

  11. STATISTICAL EVALUATION OF SMALL SCALE MIXING DEMONSTRATION SAMPLING AND BATCH TRANSFER PERFORMANCE - 12093

    Energy Technology Data Exchange (ETDEWEB)

    GREER DA; THIEN MG

    2012-01-12

    The ability to effectively mix, sample, certify, and deliver consistent batches of High Level Waste (HLW) feed from the Hanford Double Shell Tanks (DST) to the Waste Treatment and Immobilization Plant (WTP) presents a significant mission risk with potential to impact mission length and the quantity of HLW glass produced. DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS) has previously presented the results of mixing performance in two different sizes of small scale DSTs to support scale up estimates of full scale DST mixing performance. Currently, sufficient sampling of DSTs is one of the largest programmatic risks that could prevent timely delivery of high level waste to the WTP. WRPS has performed small scale mixing and sampling demonstrations to study the ability to sufficiently sample the tanks. The statistical evaluation of the demonstration results which lead to the conclusion that the two scales of small DST are behaving similarly and that full scale performance is predictable will be presented. This work is essential to reduce the risk of requiring a new dedicated feed sampling facility and will guide future optimization work to ensure the waste feed delivery mission will be accomplished successfully. This paper will focus on the analytical data collected from mixing, sampling, and batch transfer testing from the small scale mixing demonstration tanks and how those data are being interpreted to begin to understand the relationship between samples taken prior to transfer and samples from the subsequent batches transferred. An overview of the types of data collected and examples of typical raw data will be provided. The paper will then discuss the processing and manipulation of the data which is necessary to begin evaluating sampling and batch transfer performance. This discussion will also include the evaluation of the analytical measurement capability with regard to the simulant material used in the demonstration tests. The

  12. 3D PHOTOGRAPHS IN CULTURAL HERITAGE

    Directory of Open Access Journals (Sweden)

    W. Schuhr

    2013-07-01

    Full Text Available This paper on providing "oo-information" (= objective object-information on cultural monuments and sites, based on 3D photographs is also a contribution of CIPA task group 3 to the 2013 CIPA Symposium in Strasbourg. To stimulate the interest in 3D photography for scientists as well as for amateurs, 3D-Masterpieces are presented. Exemplary it is shown, due to their high documentary value ("near reality", 3D photography support, e.g. the recording, the visualization, the interpretation, the preservation and the restoration of architectural and archaeological objects. This also includes samples for excavation documentation, 3D coordinate calculation, 3D photographs applied for virtual museum purposes and as educational tools. In addition 3D photography is used for virtual museum purposes, as well as an educational tool and for spatial structure enhancement, which in particular holds for inscriptions and in rock arts. This paper is also an invitation to participate in a systematic survey on existing international archives of 3D photographs. In this respect it is also reported on first results, to define an optimum digitization rate for analog stereo views. It is more than overdue, in addition to the access to international archives for 3D photography, the available 3D photography data should appear in a global GIS(cloud-system, like on, e.g., google earth. This contribution also deals with exposing new 3D photographs to document monuments of importance for Cultural Heritage, including the use of 3D and single lense cameras from a 10m telescope staff, to be used for extremely low earth based airborne 3D photography, as well as for "underwater staff photography". In addition it is reported on the use of captive balloon and drone platforms for 3D photography in Cultural Heritage. It is liked to emphasize, the still underestimated 3D effect on real objects even allows, e.g., the spatial perception of extremely small scratches as well as of nuances in

  13. Performance of the Lot Quality Assurance Sampling Method Compared to Surveillance for Identifying Inadequately-performing Areas in Matlab, Bangladesh

    OpenAIRE

    Bhuiya, Abbas; Hanifi, S.M.A.; Roy, Nikhil; Streatfield, P. Kim

    2007-01-01

    This paper compared the performance of the lot quality assurance sampling (LQAS) method in identifying inadequately-performing health work-areas with that of using health and demographic surveillance system (HDSS) data and examined the feasibility of applying the method by field-level programme supervisors. The study was carried out in Matlab, the field site of ICDDR,B, where a HDSS has been in place for over 30 years. The LQAS method was applied in 57 work-areas of community health workers i...

  14. Oscilloscope trace photograph digitizing system (TRACE)

    International Nuclear Information System (INIS)

    Richards, M.; Dabbs, R.D.

    1977-10-01

    The digitizing system allows digitization of photographs or sketches of waveforms and then the computer is used to reduce and analyze the data. The software allows for alignment, calibration, removal of baselines, removal of unwanted points and addition of new points which makes for a fairly versatile system as far as data reduction and manipulation are concerned. System considerations are introduced first to orient the potential user to the process of digitizing information. The start up and actual commands for TRACE are discussed. Detailed descriptions of each subroutine and program section are also provided. Three general examples of typical photographs are included. A partial listing of FAWTEK is made available. Once suitable arrays that contain the data are arranged, ''GO FA'' (active FAWTEK) and many mathematical operations to further analyze the data may be performed

  15. Scanning negatives and slides digitizing your photographic archive

    CERN Document Server

    Steinhoff, Sascha

    2009-01-01

    Many photographers have either moved into digital photography exclusively or use both analog and digital media in their work. In either case, there is sure to be an archive of slides and negatives that cannot be directly integrated into the new digital workflow, nor can it be archived in a digital format. Increasingly, photographers are trying to bridge this gap with the use of high-performance film scanners. In this 2nd edition, you will learn how to achieve the best possible digital image from a negative or a slide, and how to build a workflow to make this process efficient, repeatable, and reliable. The author uses Nikon's film scanners, but all steps can easily be accomplished while using a different scanner. The most common software tools for scanning (SilverFast, VueScan, NikonScan) are not only covered extensively in the book, but trial versions are also provided on a DVD, which also contains other useful tools for image editing, as well as numerous sample scans.

  16. Performance of the lot quality assurance sampling method compared to surveillance for identifying inadequately-performing areas in Matlab, Bangladesh.

    Science.gov (United States)

    Bhuiya, Abbas; Hanifi, S M A; Roy, Nikhil; Streatfield, P Kim

    2007-03-01

    This paper compared the performance of the lot quality assurance sampling (LQAS) method in identifying inadequately-performing health work-areas with that of using health and demographic surveillance system (HDSS) data and examined the feasibility of applying the method by field-level programme supervisors. The study was carried out in Matlab, the field site of ICDDR,B, where a HDSS has been in place for over 30 years. The LQAS method was applied in 57 work-areas of community health workers in ICDDR,B-served areas in Matlab during July-September 2002. The performance of the LQAS method in identifying work-areas with adequate and inadequate coverage of various health services was compared with those of the HDSS. The health service-coverage indicators included coverage of DPT, measles, BCG vaccination, and contraceptive use. It was observed that the difference in the proportion of work-areas identified to be inadequately performing using the LQAS method with less than 30 respondents, and the HDSS was not statistically significant. The consistency between the LQAS method and the HDSS in identifying work-areas was greater for adequately-performing areas than inadequately-performing areas. It was also observed that the field managers could be trained to apply the LQAS method in monitoring their performance in reaching the target population.

  17. Comparison of the performances of the CS model coil and the Good Joint SULTAN sample

    International Nuclear Information System (INIS)

    Wesche, Rainer; Herzog, Robert; Bruzzone, Pierluigi

    2008-01-01

    The relevance of short sample measurements in SULTAN for the prediction of the performance of the coils of the International Thermonuclear Experimental Reactor (ITER) is assessed using the case of the Nb 3 Sn high-field central solenoid model coil (CSMC) conductor, for which both coil performance and short sample SULTAN results (Good Joint (GJ) sample) are available. A least-squares fit procedure, based on a uniform current distribution among the strands and the Durham scaling relations for the field, temperature and strain dependences of the strand J c provides a thermal strain of -0.294% and a degradation factor of approximately 60% for the GJ sample. In the calculation of the voltage along Layer 1A of the CSMC the hoop stress and the variation of the magnetic field in the conductor cross-section were taken into account. The temperature profile, used in the calculations, is based on published temperature profiles and empirical relations between helium inlet and outlet temperatures. A comparison with the GJ results indicates that short sample measurements in SULTAN provide a conservative estimate of the coil performance

  18. Single point aerosol sampling: Evaluation of mixing and probe performance in a nuclear stack

    Energy Technology Data Exchange (ETDEWEB)

    Rodgers, J.C.; Fairchild, C.I.; Wood, G.O. [Los Alamos National Laboratory, NM (United States)] [and others

    1995-02-01

    Alternative Reference Methodologies (ARMs) have been developed for sampling of radionuclides from stacks and ducts that differ from the methods required by the U.S. EPA. The EPA methods are prescriptive in selection of sampling locations and in design of sampling probes whereas the alternative methods are performance driven. Tests were conducted in a stack at Los Alamos National Laboratory to demonstrate the efficacy of the ARMs. Coefficients of variation of the velocity tracer gas, and aerosol particle profiles were determined at three sampling locations. Results showed numerical criteria placed upon the coefficients of variation by the ARMs were met at sampling stations located 9 and 14 stack diameters from flow entrance, but not at a location that is 1.5 diameters downstream from the inlet. Experiments were conducted to characterize the transmission of 10 {mu}m aerodynamic equivalent diameter liquid aerosol particles through three types of sampling probes. The transmission ratio (ratio of aerosol concentration at the probe exit plane to the concentration in the free stream) was 107% for a 113 L/min (4-cfm) anisokinetic shrouded probe, but only 20% for an isokinetic probe that follows the EPA requirements. A specially designed isokinetic probe showed a transmission ratio of 63%. The shrouded probe performance would conform to the ARM criteria; however, the isokinetic probes would not.

  19. The Relationship between Mental Health, Acculturative Stress, and Academic Performance in a Latino Middle School Sample

    Science.gov (United States)

    Albeg, Loren J.; Castro-Olivo, Sara M.

    2014-01-01

    This study evaluated the relationship between acculturative stress, symptoms of internalizing mental health problems, and academic performance in a sample of 94 Latino middle school students. Students reported on symptoms indicative of depression and anxiety related problems and acculturative stress. Teachers reported on students' academic…

  20. DETERMINATION OF CHLOROPHEONIS, NITROPHENOIS AND METHYLPHENOIS IN GROUND-WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Science.gov (United States)

    A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...

  1. DETERMINATION OF CHLOROPHENOLS, NITROPHENOLS, AND METHYLPHENOLS IN GROUND-WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Science.gov (United States)

    A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...

  2. Associations Between Academic and Motor Performance in a Heterogeneous Sample of Children With Learning Disabilities

    NARCIS (Netherlands)

    Vuijk, Pieter Jelle; Hartman, Esther; Mombarg, Remo; Scherder, Erik; Visscher, Chris

    2011-01-01

    A heterogeneous sample of 137 school-aged children with learning disabilities (IQ > 80) attending special needs schools was examined on the Movement Assessment Battery for Children (MABC). The results show that compared to the available norm scores, 52.6% of the children tested performed below the

  3. How to best freeze liver samples to perform the in vivo mammalian alkaline comet assay

    Directory of Open Access Journals (Sweden)

    José Manuel Enciso Gadea

    2015-06-01

    None of the different methods used was capable of giving good results, except immersing the liver samples in liquid nitrogen, followed by Jackson’s et al. (2013 thawing protocol, suggesting that the thawing process may be as critical as the freezing process. To sum up, these results highlight the importance of deepening the possibility to perform the comet assay with frozen tissue.

  4. Spatial delayed nonmatching-to-sample performances in long-living Ames dwarf mice.

    Science.gov (United States)

    Derenne, Adam; Brown-Borg, Holly M; Martner, Sarah; Wolff, Wendy; Frerking, Morgan

    2014-01-17

    Ames dwarf mice have an extended lifespan by comparison with normal mice. Behavioral testing has revealed that sometimes Ames dwarf mice also evince superior performances relative to normal mice, but in other cases they do not. In this experiment, Ames dwarf and normal mice were compared on a T-maze test and on a delayed nonmatching-to-sample variant of a T-maze test. On the simple T-maze, Ames dwarf and normal mice committed comparable numbers of errors. On the nonmatching-to-sample task, normal mice mastered the discrimination by the end of the experiment while Ames dwarf mice did not. The apparatus, distances traveled and session duration were equivalent between the two tasks. The poorer performances of Ames dwarf mice on the nonmatching-to-sample task suggests that Ames dwarf mice may not be as capable of learning relatively cognitively complex tasks as normal mice. © 2013.

  5. Experiencing Photographs Qua Photographs: What's So Special about Them?

    Directory of Open Access Journals (Sweden)

    Jiri Benovsky

    2013-01-01

    Full Text Available Merely rhetorically and answering in the negative, Kendall Walton has asked: "Isn't photography just another method people have of making pictures, one that merely uses different tools and materials; cameras, photosensitive paper, and darkroom equipment, rather than canvas, paint, and brushes? And don't the results differ only contingently and in degree, not fundamentally, from pictures of other kinds?" Contrary to Walton and others, I answer with a resounding "Yes" to Walton’s questions in this article. It is a widely shared view that photographs are somehow special and that they fundamentally differ from hand-made pictures such as paintings, both from a phenomenological point of view (in the way we experience them and an epistemic point of view (since they are supposed to have a different that is, greater, epistemic value from paintings that gives us a privileged access to the world. I almost reject the totality of these claims and, as a consequence, there remains little difference between photographs and paintings. As we shall see, “photographs are always partly paintings,” a claim that is true not only of retouched digital photographs but of all photographs, including traditional ones made using photosensitive film and development techniques.

  6. Impact of Cesium decontamination on performances of high activity sample analysis

    Energy Technology Data Exchange (ETDEWEB)

    Maillard, Christophe; Boyer-Deslys, Valerie; Dautheribes, Jean L.; Esbelin, Eric; Beres, Andre; Jan, Steve; Baghdadi, Sarah; Rivier, Cedric [CEA, Nuclear Energy Division, Bagnols sur Ceze (France). RadioChemistry and Processes Dept.

    2017-09-01

    Experiments in the ATALANTE facility can lead to high activity samples (for example the dissolution of hulls and spent fuels), essentially coming from the presence of {sup 137}Cs. Usually, these samples are handled in a shielded cell. The removal of this radionuclide from the sample would make it possible to handle it in glove boxes without having to perform an important dilution in the shielded cells beforehand. It would allow to analyze samples using techniques usually implemented in glove boxes (such as ICP, α spectrometry..) and to reach lower detection and quantification limits. To do so, a separation by extraction chromatography using a Triskem AMP-PAN column was developed. A cesium decontamination factor higher than 5 x 10{sup 4} and detection limits improvement up to a factor 100 were obtained.

  7. Performance Evaluation of Commercial Dengue Diagnostic Tests for Early Detection of Dengue in Clinical Samples

    Directory of Open Access Journals (Sweden)

    Tuan Nur Akmalina Mat Jusoh

    2017-01-01

    Full Text Available The shattering rise in dengue virus infections globally has created a need for an accurate and validated rapid diagnostic test for this virus. Rapid diagnostic test (RDT and reverse transcription-polymerase chain reaction (RT-PCR diagnostic detection are useful tools for diagnosis of early dengue infection. We prospectively evaluated the diagnostic performance of nonstructural 1 (NS1 RDT and real-time RT-PCR diagnostic kits in 86 patient serum samples. Thirty-six samples were positive for dengue NS1 antigen while the remaining 50 were negative when tested with enzyme-linked immunosorbent assay (ELISA. Commercially available RDTs for NS1 detection, RTK ProDetect™, and SD Bioline showed high sensitivity of 94% and 89%, respectively, compared with ELISA. GenoAmp® Trioplex Real-Time RT-PCR and RealStar® Dengue RT-PCR tests presented a comparable kappa agreement with 0.722. The result obtained from GenoAmp® Real-Time RT-PCR Dengue test showed that 14 samples harbored dengue virus type 1 (DENV-1, 8 samples harbored DENV-2, 2 samples harbored DENV-3, and 1 sample harbored DENV-4. 1 sample had a double infection with DENV-1 and DENV-2. The NS1 RDTs and real-time RT-PCR tests were found to be a useful diagnostic for early and rapid diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.

  8. Recommended procedures for performance testing of radiobioassay laboratories: Volume 2, In vitro samples

    International Nuclear Information System (INIS)

    Fenrick, H.W.; MacLellan, J.A.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard specifies the criteria for defining the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of in vitro test samples (artificial urine and fecal matter) for indirect bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented. 8 refs., 3 tabs

  9. Delayed match-to-sample early performance decrement in monkeys after 60Co irradiation

    International Nuclear Information System (INIS)

    Bruner, A.; Bogo, V.; Jones, R.K.

    1975-01-01

    Sixteen monkeys were trained on a delayed match-to-sample task (DMTS) based on shock avoidance and irradiated with single, whole-body exposures of from 396 to 2000 rad 60 Co (midbody dose) at between 163 and 233 rad/min. Pre- to post-irradiation performance changes were assessed using a penalty-scaling measure which differentially weighted incorrect responses, response omissions, and error-omission sequences. Thirteen of the animals displayed early performance decrement, including five incapacitations, at lower doses (less than 1000 rad) than heretofore found effective. This was considered a function of task complexity, measurement sensitivity, and gamma effectiveness. The minimum effective midbody dose for inducing decrement using the DMTS task was estimated to be on the order of 500 rad. The nature of early, transient performance decrement seems to reflect more of an inability to perform than an inability to perform correctly

  10. Registration of 3-dimensional facial photographs for clinical use.

    Science.gov (United States)

    Maal, Thomas J J; van Loon, Bram; Plooij, Joanneke M; Rangel, Frits; Ettema, Anke M; Borstlap, Wilfred A; Bergé, Stefaan J

    2010-10-01

    To objectively evaluate treatment outcomes in oral and maxillofacial surgery, pre- and post-treatment 3-dimensional (3D) photographs of the patient's face can be registered. For clinical use, it is of great importance that this registration process is accurate (photographs were captured at 3 different times: baseline (T(0)), after 1 minute (T(1)), and 3 weeks later (T(2)). Furthermore, a 3D photograph of the volunteer laughing (T(L)) was acquired to investigate the effect of facial expression. Two different registration methods were used to register the photographs acquired at all different times: surface-based registration and reference-based registration. Within the surface-based registration, 2 different software packages (Maxilim [Medicim NV, Mechelen, Belgium] and 3dMD Patient [3dMD LLC, Atlanta, GA]) were used to register the 3D photographs acquired at the various times. The surface-based registration process was repeated with the preprocessed photographs. Reference-based registration (Maxilim) was performed twice by 2 observers investigating the inter- and intraobserver error. The mean registration errors are small for the 3D photographs at rest (0.39 mm for T(0)-T(1) and 0.52 mm for T(0)-T(2)). The mean registration error increased to 1.2 mm for the registration between the 3D photographs acquired at T(0) and T(L). The mean registration error for the reference-based method was 1.0 mm for T(0)-T(1), 1.1 mm for T(0)-T(2), and 1.5 mm for T(0) and T(L). The mean registration errors for the preprocessed photographs were even smaller (0.30 mm for T(0)-T(1), 0.42 mm for T(0)-T(2), and 1.2 mm for T(0) and T(L)). Furthermore, a strong correlation between the results of both software packages used for surface-based registration was found. The intra- and interobserver error for the reference-based registration method was found to be 1.2 and 1.0 mm, respectively. Surface-based registration is an accurate method to compare 3D photographs of the same individual at

  11. Evaluation of surface sampling method performance for Bacillus Spores on clean and dirty outdoor surfaces.

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Mollye C.; Einfeld, Wayne; Boucher, Raymond M.; Brown, Gary Stephen; Tezak, Matthew Stephen

    2011-06-01

    Recovery of Bacillus atrophaeous spores from grime-treated and clean surfaces was measured in a controlled chamber study to assess sampling method performance. Outdoor surfaces investigated by wipe and vacuum sampling methods included stainless steel, glass, marble and concrete. Bacillus atrophaeous spores were used as a surrogate for Bacillus anthracis spores in this study designed to assess whether grime-coated surfaces significantly affected surface sampling method performance when compared to clean surfaces. A series of chamber tests were carried out in which known amounts of spores were allowed to gravitationally settle onto both clean and dirty surfaces. Reference coupons were co-located with test coupons in all chamber experiments to provide a quantitative measure of initial surface concentrations of spores on all surfaces, thereby allowing sampling recovery calculations. Results from these tests, carried out under both low and high humidity conditions, show that spore recovery from grime-coated surfaces is the same as or better than spore recovery from clean surfaces. Statistically significant differences between method performance for grime-coated and clean surfaces were observed in only about half of the chamber tests conducted.

  12. Determination of rock fragmentation based on a photographic technique

    International Nuclear Information System (INIS)

    Dehgan Banadaki, M.M.; Majdi, A.; Raessi Gahrooei, D.

    2002-01-01

    The paper represents a physical blasting model in laboratory scale along with a photographic approach to describe the distribution of blasted rock materials. For this purpose, based on wobble probability distribution function, eight samples each weighted 100 kg,were obtained. Four pictures from four different section of each sample were taken. Then, pictures were converted into graphic files with characterizing boundary of each piece of rocks in the samples. Error caused due to perspective were eliminated. Volume of each piece of the blasted rock materials and hence the required sieve size, each piece of rock to pass through, were calculated. Finally, original blasted rock size distribution was compared with that obtained from the photographic method. The paper concludes with presenting an approach to convert the results of photographic technique into size distribution obtained by seine analysis with sufficient verification

  13. Overestimation of test performance by ROC analysis: Effect of small sample size

    International Nuclear Information System (INIS)

    Seeley, G.W.; Borgstrom, M.C.; Patton, D.D.; Myers, K.J.; Barrett, H.H.

    1984-01-01

    New imaging systems are often observer-rated by ROC techniques. For practical reasons the number of different images, or sample size (SS), is kept small. Any systematic bias due to small SS would bias system evaluation. The authors set about to determine whether the area under the ROC curve (AUC) would be systematically biased by small SS. Monte Carlo techniques were used to simulate observer performance in distinguishing signal (SN) from noise (N) on a 6-point scale; P(SN) = P(N) = .5. Four sample sizes (15, 25, 50 and 100 each of SN and N), three ROC slopes (0.8, 1.0 and 1.25), and three intercepts (0.8, 1.0 and 1.25) were considered. In each of the 36 combinations of SS, slope and intercept, 2000 runs were simulated. Results showed a systematic bias: the observed AUC exceeded the expected AUC in every one of the 36 combinations for all sample sizes, with the smallest sample sizes having the largest bias. This suggests that evaluations of imaging systems using ROC curves based on small sample size systematically overestimate system performance. The effect is consistent but subtle (maximum 10% of AUC standard deviation), and is probably masked by the s.d. in most practical settings. Although there is a statistically significant effect (F = 33.34, P<0.0001) due to sample size, none was found for either the ROC curve slope or intercept. Overestimation of test performance by small SS seems to be an inherent characteristic of the ROC technique that has not previously been described

  14. Chance constrained problems: penalty reformulation and performance of sample approximation technique

    Czech Academy of Sciences Publication Activity Database

    Branda, Martin

    2012-01-01

    Roč. 48, č. 1 (2012), s. 105-122 ISSN 0023-5954 R&D Projects: GA ČR(CZ) GBP402/12/G097 Institutional research plan: CEZ:AV0Z10750506 Keywords : chance constrained problems * penalty functions * asymptotic equivalence * sample approximation technique * investment problem Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.619, year: 2012 http://library.utia.cas.cz/separaty/2012/E/branda-chance constrained problems penalty reformulation and performance of sample approximation technique.pdf

  15. Evaluating the performance of species richness estimators: sensitivity to sample grain size

    DEFF Research Database (Denmark)

    Hortal, Joaquín; Borges, Paulo A. V.; Gaspar, Clara

    2006-01-01

    and several recent estimators [proposed by Rosenzweig et al. (Conservation Biology, 2003, 17, 864-874), and Ugland et al. (Journal of Animal Ecology, 2003, 72, 888-897)] performed poorly. 3.  Estimations developed using the smaller grain sizes (pair of traps, traps, records and individuals) presented similar....... Data obtained with standardized sampling of 78 transects in natural forest remnants of five islands were aggregated in seven different grains (i.e. ways of defining a single sample): islands, natural areas, transects, pairs of traps, traps, database records and individuals to assess the effect of using...

  16. Small Scale Mixing Demonstration Batch Transfer and Sampling Performance of Simulated HLW - 12307

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Jesse; Townson, Paul; Vanatta, Matt [EnergySolutions, Engineering and Technology Group, Richland, WA, 99354 (United States)

    2012-07-01

    The ability to effectively mix, sample, certify, and deliver consistent batches of High Level Waste (HLW) feed from the Hanford Double Shell Tanks (DST) to the Waste treatment Plant (WTP) has been recognized as a significant mission risk with potential to impact mission length and the quantity of HLW glass produced. At the end of 2009 DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS), awarded a contract to EnergySolutions to design, fabricate and operate a demonstration platform called the Small Scale Mixing Demonstration (SSMD) to establish pre-transfer sampling capacity, and batch transfer performance data at two different scales. This data will be used to examine the baseline capacity for a tank mixed via rotational jet mixers to transfer consistent or bounding batches, and provide scale up information to predict full scale operational performance. This information will then in turn be used to define the baseline capacity of such a system to transfer and sample batches sent to WTP. The Small Scale Mixing Demonstration (SSMD) platform consists of 43'' and 120'' diameter clear acrylic test vessels, each equipped with two scaled jet mixer pump assemblies, and all supporting vessels, controls, services, and simulant make up facilities. All tank internals have been modeled including the air lift circulators (ALCs), the steam heating coil, and the radius between the wall and floor. The test vessels are set up to simulate the transfer of HLW out of a mixed tank, and collect a pre-transfer sample in a manner similar to the proposed baseline configuration. The collected material is submitted to an NQA-1 laboratory for chemical analysis. Previous work has been done to assess tank mixing performance at both scales. This work involved a combination of unique instruments to understand the three dimensional distribution of solids using a combination of Coriolis meter measurements, in situ chord length distribution

  17. Use of proficiency samples to assess diagnostic laboratories in France performing a Trichinella digestion assay.

    Science.gov (United States)

    Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal

    2007-07-01

    Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.

  18. Laboratory EXAFS using photographic method

    International Nuclear Information System (INIS)

    Joshi, S K; Gaur, A; Johari, A; Shrivastava, B D

    2009-01-01

    Laboratory EXAFS facilities have been used since long. However, EXAFS data analysis has not been reported as yet for the spectra recorded photographically. Though from our laboratory we have been reporting various studies employing X-ray spectrographs using the photographic method of registration of EXAFS spectra, but the data has never been analyzed using the Fourier transformation method and fitting with standards. This paper reports the study of copper metal EXAFS spectra at the K-edge recorded photographically employing a 400 mm curved mica crystal Cauchois type spectrograph with 0.5 kW tungsten target X-ray tube. The data obtained in digital form with the help of a microphotometer has been processed using EXAFS data analysis programs Athena and Artemis. The experimental data for copper metal foil have been fitted with the theoretical standards. The results have been compared with those obtained from another laboratory EXAFS set up employing 12 kW Rigaku rotating anode, Johansson-type spectrometer with Si(311) monochromator crystal and scintillation counter. The results have also been compared with those obtained from SSRL. The parameters obtained for the first two shells from the photographic method are comparable with those obtained from the other two methods. The present work shows that the photographic method of registering EXAFS spectra in laboratory set up using fixed target X-ray tubes can also be used for getting structural information at least for the first two coordination shells.

  19. Laboratory EXAFS using photographic method

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, S K [Government College, Badnawar (Dhar)-454660 (India); Gaur, A; Johari, A; Shrivastava, B D, E-mail: joshisantoshk@yahoo.co [School of Studies in Physics, Vikram University, Ujjain-456010 (India)

    2009-11-15

    Laboratory EXAFS facilities have been used since long. However, EXAFS data analysis has not been reported as yet for the spectra recorded photographically. Though from our laboratory we have been reporting various studies employing X-ray spectrographs using the photographic method of registration of EXAFS spectra, but the data has never been analyzed using the Fourier transformation method and fitting with standards. This paper reports the study of copper metal EXAFS spectra at the K-edge recorded photographically employing a 400 mm curved mica crystal Cauchois type spectrograph with 0.5 kW tungsten target X-ray tube. The data obtained in digital form with the help of a microphotometer has been processed using EXAFS data analysis programs Athena and Artemis. The experimental data for copper metal foil have been fitted with the theoretical standards. The results have been compared with those obtained from another laboratory EXAFS set up employing 12 kW Rigaku rotating anode, Johansson-type spectrometer with Si(311) monochromator crystal and scintillation counter. The results have also been compared with those obtained from SSRL. The parameters obtained for the first two shells from the photographic method are comparable with those obtained from the other two methods. The present work shows that the photographic method of registering EXAFS spectra in laboratory set up using fixed target X-ray tubes can also be used for getting structural information at least for the first two coordination shells.

  20. Adobe Photoshop CS6 for photographers

    CERN Document Server

    Evening, Martin

    2012-01-01

    Renowned Photographer and Photoshop hall-of-famer, Martin Evening returns with his comprehensive guide to Photoshop. This acclaimed work covers everything from the core aspects of working in Photoshop to advanced techniques for refined workflows and professional results. Using concise advice, clear instruction and real world examples, this essential guide will give you the skills, regardless of your experience, to create professional quality results. A robust accompanying website features sample images, tutorial videos, bonus chapters and a plethora of extra resources. Quite simply, this is

  1. Photographic paper for determining physical parameters in radiobiological experiments with accelerated ions

    International Nuclear Information System (INIS)

    Eichhorn, K.; Regel, K.

    1979-01-01

    It is possible to display the energy flux density distribution of a beam of accelerated ions in the absorbed dose range of 1 Gy to 100 Gy with the aid of photographic paper. A special Al absorber arrangement in connection with photographic paper allows to determine both particle range and energy. Finally, photographic paper is shown to be suitable for an intercomparison of the absorbed doses of irradiated samples. (author)

  2. Finite sample performance of the E-M algorithm for ranks data modelling

    Directory of Open Access Journals (Sweden)

    Angela D'Elia

    2007-10-01

    Full Text Available We check the finite sample performance of the maximum likelihood estimators of the parameters of a mixture distribution recently introduced for modelling ranks/preference data. The estimates are derived by the E-M algorithm and the performance is evaluated both from an univariate and bivariate points of view. While the results are generally acceptable as far as it concerns the bias, the Monte Carlo experiment shows a different behaviour of the estimators efficiency for the two parameters of the mixture, mainly depending upon their location in the admissible parametric space. Some operative suggestions conclude the paer.

  3. The role of anxiety symptoms in school performance in a community sample of children and adolescents

    OpenAIRE

    Mazzone, Luigi; Ducci, Francesca; Scoto, Maria Cristina; Passaniti, Eleonora; D'Arrigo, Valentina Genitori; Vitiello, Benedetto

    2007-01-01

    Abstract Background Anxiety symptoms are relatively common among children and adolescents and can interfere with functioning. The prevalence of anxiety and the relationship between anxiety and school performance were examined among elementary, middle, and high school students. Methods Samples of elementary (N = 131, age 8–10 years), middle (N = 267, age 11–13 years), and high school (N = 80, age 14–16 years) children were recruited from four public schools in a predominantly middle-class comm...

  4. Evaluation of polyethersulfone performance for the microextraction of polar chlorinated herbicides from environmental water samples.

    Science.gov (United States)

    Prieto, Ailette; Rodil, Rosario; Quintana, José Benito; Cela, Rafael; Möder, Monika; Rodríguez, Isaac

    2014-05-01

    In this work, the suitability of bulk polyethersulfone (PES) for sorptive microextraction of eight polar, chlorinated phenoxy acids and dicamba from environmental water samples is assessed and the analytical features of the optimized method are compared to those reported for other microextraction techniques. Under optimized conditions, extractions were performed with samples (18 mL) adjusted at pH 2 and containing a 30% (w/v) of sodium chloride, using a tubular PES sorbent (1 cm length × 0.7 mm o.d., sorbent volume 8 µL). Equilibrium conditions were achieved after 3h of direct sampling, with absolute extraction efficiencies ranging from 39 to 66%, depending on the compound. Analytes were recovered soaking the polymer with 0.1 mL of ethyl acetate, derivatized and determined by gas chromatography-mass spectrometry (GC-MS). Achieved quantification limits (LOQs) varied between 0.005 and 0.073 ng mL(-1). After normalization with the internal surrogate (IS), the efficiency of the extraction was only moderately affected by the particular characteristics of different water samples (surface and sewage water); thus, pseudo-external calibration, using spiked ultrapure water solutions, can be used as quantification technique. The reduced cost of the PES polymer allowed considering it as a disposable sorbent, avoiding variations in the performance of the extraction due to cross-contamination problems and/or surface modification with usage. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Characteristic Performance Evaluation of a new SAGe Well Detector for Small and Large Sample Geometries

    International Nuclear Information System (INIS)

    Adekola, A.S.; Colaresi, J.; Douwen, J.; Jaederstroem, H.; Mueller, W.F.; Yocum, K.M.; Carmichael, K.

    2015-01-01

    Environmental scientific research requires a detector that has sensitivity low enough to reveal the presence of any contaminant in the sample at a reasonable counting time. Canberra developed the germanium detector geometry called Small Anode Germanium (SAGe) Well detector, which is now available commercially. The SAGe Well detector is a new type of low capacitance germanium well detector manufactured using small anode technology capable of advancing many environmental scientific research applications. The performance of this detector has been evaluated for a range of sample sizes and geometries counted inside the well, and on the end cap of the detector. The detector has energy resolution performance similar to semi-planar detectors, and offers significant improvement over the existing coaxial and Well detectors. Energy resolution performance of 750 eV Full Width at Half Maximum (FWHM) at 122 keV γ-ray energy and resolution of 2.0 - 2.3 keV FWHM at 1332 keV γ-ray energy are guaranteed for detector volumes up to 425 cm 3 . The SAGe Well detector offers an optional 28 mm well diameter with the same energy resolution as the standard 16 mm well. Such outstanding resolution performance will benefit environmental applications in revealing the detailed radionuclide content of samples, particularly at low energy, and will enhance the detection sensitivity resulting in reduced counting time. The detector is compatible with electric coolers without any sacrifice in performance and supports the Canberra Mathematical efficiency calibration method (In situ Object Calibration Software or ISOCS, and Laboratory Source-less Calibration Software or LABSOCS). In addition, the SAGe Well detector supports true coincidence summing available in the ISOCS/LABSOCS framework. The improved resolution performance greatly enhances detection sensitivity of this new detector for a range of sample sizes and geometries counted inside the well. This results in lower minimum detectable

  6. Characteristic Performance Evaluation of a new SAGe Well Detector for Small and Large Sample Geometries

    Energy Technology Data Exchange (ETDEWEB)

    Adekola, A.S.; Colaresi, J.; Douwen, J.; Jaederstroem, H.; Mueller, W.F.; Yocum, K.M.; Carmichael, K. [Canberra Industries Inc., 800 Research Parkway, Meriden, CT 06450 (United States)

    2015-07-01

    Environmental scientific research requires a detector that has sensitivity low enough to reveal the presence of any contaminant in the sample at a reasonable counting time. Canberra developed the germanium detector geometry called Small Anode Germanium (SAGe) Well detector, which is now available commercially. The SAGe Well detector is a new type of low capacitance germanium well detector manufactured using small anode technology capable of advancing many environmental scientific research applications. The performance of this detector has been evaluated for a range of sample sizes and geometries counted inside the well, and on the end cap of the detector. The detector has energy resolution performance similar to semi-planar detectors, and offers significant improvement over the existing coaxial and Well detectors. Energy resolution performance of 750 eV Full Width at Half Maximum (FWHM) at 122 keV γ-ray energy and resolution of 2.0 - 2.3 keV FWHM at 1332 keV γ-ray energy are guaranteed for detector volumes up to 425 cm{sup 3}. The SAGe Well detector offers an optional 28 mm well diameter with the same energy resolution as the standard 16 mm well. Such outstanding resolution performance will benefit environmental applications in revealing the detailed radionuclide content of samples, particularly at low energy, and will enhance the detection sensitivity resulting in reduced counting time. The detector is compatible with electric coolers without any sacrifice in performance and supports the Canberra Mathematical efficiency calibration method (In situ Object Calibration Software or ISOCS, and Laboratory Source-less Calibration Software or LABSOCS). In addition, the SAGe Well detector supports true coincidence summing available in the ISOCS/LABSOCS framework. The improved resolution performance greatly enhances detection sensitivity of this new detector for a range of sample sizes and geometries counted inside the well. This results in lower minimum detectable

  7. Adobe Photoshop CC for photographers

    CERN Document Server

    Evening, Martin

    2014-01-01

    Adobe Photoshop for Photographers 2014 Release by Photoshop hall-of-famer and acclaimed digital imaging professional Martin Evening has been fully updated to include detailed instruction for all of the updates to Photoshop CC 2014 on Adobe's Creative Cloud, including significant new features, such as Focus Area selections, enhanced Content-Aware filling, and new Spin and Path blur gallery effects. This guide covers all the tools and techniques photographers and professional image editors need to know when using Photoshop, from workflow guidance to core skills to advanced techniques for profess

  8. Performance of a hydrostatic sampler for collecting samples at the water-sediment interface in lakes

    Directory of Open Access Journals (Sweden)

    Fernando PEDROZO

    2008-02-01

    Full Text Available The water-sediment interface plays a significant role in the determination of the trophic degree of a waterbody. Numerous redox reactions take place there, resulting in the release of contaminants from the sediments to the water column. The aim of the present work was to develop an equipment for collecting samples from the water-sediment interface. Such equipment was to have a simple design, low construction cost, no depth limitations, and high levels of personal safety and to be reliable in the collection of samples. The performance of the hydrostatic sampler thus developed was tested against samples collected either remotely with a corer or directly with syringes by autonomous divers. The hydrostatic sampler permits access to depths where the costs of the traditional diving methodology are expensive, and where working conditions are dangerous for the diver. The hydrostatic sampler provides an additional means of collecting samples from the water-sediment interface, which together with pore-water samples, facilitates the investigation and understanding of chemical mechanisms in lakes, for instance, those that control the P release from sediment to the water column.

  9. Effect of the Target Motion Sampling Temperature Treatment Method on the Statistics and Performance

    Science.gov (United States)

    Viitanen, Tuomas; Leppänen, Jaakko

    2014-06-01

    Target Motion Sampling (TMS) is a stochastic on-the-fly temperature treatment technique that is being developed as a part of the Monte Carlo reactor physics code Serpent. The method provides for modeling of arbitrary temperatures in continuous-energy Monte Carlo tracking routines with only one set of cross sections stored in the computer memory. Previously, only the performance of the TMS method in terms of CPU time per transported neutron has been discussed. Since the effective cross sections are not calculated at any point of a transport simulation with TMS, reaction rate estimators must be scored using sampled cross sections, which is expected to increase the variances and, consequently, to decrease the figures-of-merit. This paper examines the effects of the TMS on the statistics and performance in practical calculations involving reaction rate estimation with collision estimators. Against all expectations it turned out that the usage of sampled response values has no practical effect on the performance of reaction rate estimators when using TMS with elevated basis cross section temperatures (EBT), i.e. the usual way. With 0 Kelvin cross sections a significant increase in the variances of capture rate estimators was observed right below the energy region of unresolved resonances, but at these energies the figures-of-merit could be increased using a simple resampling technique to decrease the variances of the responses. It was, however, noticed that the usage of the TMS method increases the statistical deviances of all estimators, including the flux estimator, by tens of percents in the vicinity of very strong resonances. This effect is actually not related to the usage of sampled responses, but is instead an inherent property of the TMS tracking method and concerns both EBT and 0 K calculations.

  10. Examiner Reliability of Fluorosis Scoring: A Comparison of Photographic and Clinical Examination Findings

    Science.gov (United States)

    Cruz-Orcutt, Noemi; Warren, John J.; Broffitt, Barbara; Levy, Steven M.; Weber-Gasparoni, Karin

    2012-01-01

    Objective To assess and compare examiner reliability of clinical and photographic fluorosis examinations using the Fluorosis Risk Index (FRI) among children in the Iowa Fluoride Study (IFS). Methods The IFS examined 538 children for fluorosis and dental caries at age 13 and obtained intra-oral photographs from nearly all of them. To assess examiner reliability, duplicate clinical examinations were conducted for 40 of the subjects. In addition, 200 of the photographs were scored independently for fluorosis by two examiners in a standardized manner. Fluorosis data were compared between examiners for the clinical exams and separately for the photographic exams, and a comparison was made between clinical and photographic exams. For all 3 comparisons, examiner reliability was assessed using kappa statistics at the tooth level. Results Inter-examiner reliability for the duplicate clinical exams on the sample of 40 subjects as measured by kappa was 0.59, while the repeat exams of the 200 photographs yielded a kappa of 0.64. For the comparison of photographic and clinical exams, inter-examiner reliability, as measured by weighted kappa, was 0.46. FRI scores obtained using the photographs were higher on average than those obtained from the clinical exams. Fluorosis prevalence was higher for photographs (33%) than found for clinical exam (18%). Conclusion Results suggest inter-examiner reliability is greater and fluorosis scores higher when using photographic compared to clinical examinations. PMID:22316120

  11. Safety analysis report for packaging (onsite) transuranic performance demonstration program sample packaging

    International Nuclear Information System (INIS)

    Mccoy, J.C.

    1997-01-01

    The Transuranic Performance Demonstration Program (TPDP) sample packaging is used to transport highway route controlled quantities of weapons grade (WG) plutonium samples from the Plutonium Finishing Plant (PFP) to the Waste Receiving and Processing (WRAP) facility and back. The purpose of these shipments is to test the nondestructive assay equipment in the WRAP facility as part of the Nondestructive Waste Assay PDP. The PDP is part of the U. S. Department of Energy (DOE) National TRU Program managed by the U. S. Department of Energy, Carlsbad Area Office, Carlsbad, New Mexico. Details of this program are found in CAO-94-1045, Performance Demonstration Program Plan for Nondestructive Assay for the TRU Waste Characterization Program (CAO 1994); INEL-96/0129, Design of Benign Matrix Drums for the Non-Destructive Assay Performance Demonstration Program for the National TRU Program (INEL 1996a); and INEL-96/0245, Design of Phase 1 Radioactive Working Reference Materials for the Nondestructive Assay Performance Demonstration Program for the National TRU Program (INEL 1996b). Other program documentation is maintained by the national TRU program and each DOE site participating in the program. This safety analysis report for packaging (SARP) provides the analyses and evaluations necessary to demonstrate that the TRU PDP sample packaging meets the onsite transportation safety requirements of WHC-CM-2-14, Hazardous Material Packaging and Shipping, for an onsite Transportation Hazard Indicator (THI) 2 packaging. This SARP, however, does not include evaluation of any operations within the PFP or WRAP facilities, including handling, maintenance, storage, or operating requirements, except as they apply directly to transportation between the gate of PFP and the gate of the WRAP facility. All other activities are subject to the requirements of the facility safety analysis reports (FSAR) of the PFP or WRAP facility and requirements of the PDP

  12. A note on photographing otoliths

    African Journals Online (AJOL)

    The sagiu..al otoliths of rlShes have in recent years become importanttuonomic aids. Forthis purpose high quality photographs have become essential to illustrate such fine: structures as the crislae and the colliculi which art often useful in distinguishing between closely related species. The method described bdow proved ...

  13. Globes, Maps, Photographs: Geographic Tools.

    Science.gov (United States)

    McDermott, Paul D.; And Others

    This compilation of reprinted articles that originally appeared in the Journal of Geography from September 1969 through the May 1970 issues, is intended to help teachers use globes, maps, and photographs with skill and understanding. The articles were designed with several objectives in mind: 1) to provide information regarding the design,…

  14. Classifier-guided sampling for discrete variable, discontinuous design space exploration: Convergence and computational performance

    Energy Technology Data Exchange (ETDEWEB)

    Backlund, Peter B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Shahan, David W. [HRL Labs., LLC, Malibu, CA (United States); Seepersad, Carolyn Conner [Univ. of Texas, Austin, TX (United States)

    2014-04-22

    A classifier-guided sampling (CGS) method is introduced for solving engineering design optimization problems with discrete and/or continuous variables and continuous and/or discontinuous responses. The method merges concepts from metamodel-guided sampling and population-based optimization algorithms. The CGS method uses a Bayesian network classifier for predicting the performance of new designs based on a set of known observations or training points. Unlike most metamodeling techniques, however, the classifier assigns a categorical class label to a new design, rather than predicting the resulting response in continuous space, and thereby accommodates nondifferentiable and discontinuous functions of discrete or categorical variables. The CGS method uses these classifiers to guide a population-based sampling process towards combinations of discrete and/or continuous variable values with a high probability of yielding preferred performance. Accordingly, the CGS method is appropriate for discrete/discontinuous design problems that are ill-suited for conventional metamodeling techniques and too computationally expensive to be solved by population-based algorithms alone. In addition, the rates of convergence and computational properties of the CGS method are investigated when applied to a set of discrete variable optimization problems. Results show that the CGS method significantly improves the rate of convergence towards known global optima, on average, when compared to genetic algorithms.

  15. Evaluation of the performance of the shields in the EPMAs used for radioactive samples

    International Nuclear Information System (INIS)

    Matsui, Hiroki; Suzuki, Miho; Obata, Hiroki; Kanazawa, Hiroyuki

    2014-06-01

    The Reactor Fuel Examination Facility (RFEF) in Japan Atomic Energy Agency (JAEA) has been used for Post Irradiation Examinations (PIEs) to verify the reliability and safety of the nuclear fuels irradiated in commercial reactors. EPMA (Electron Probe Micro Analyzer) has been utilized for the qualitative analysis of the fission product in the fuel pellet and the detailed observation of the oxide layers formed at the inner and outer surfaces of fuel cladding. Commercial EPMAs were remodeled so that the EPMAs can be applied for radioactive samples. Several shields were set in the EPMA to avoid the gamma-rays which radiate from a radioactive sample to the proportional counter in the EPMA. It is important to calculate this shielding performance adequately to maintain the precision of analysis. This report describes the results of re-evaluation of the performance of the shields in the EPMAs in the RFEF by using the Particle and Heavy Ion Transport Code System (PHITS) and the examination results of gamma-ray effect to the X-ray spectrum data by using a radioactive sample. (author)

  16. Electromembrane extraction of tartrazine from food samples: Effects of nano-sorbents on membrane performance.

    Science.gov (United States)

    Yaripour, Saeid; Mohammadi, Ali; Nojavan, Saeed

    2016-07-01

    In the present study, for the first time electromembrane extraction followed by high-performance liquid chromatography coupled with ultraviolet detection was developed and validated for the determination of tartrazine in some food samples. The parameters influencing electromembrane extraction were evaluated and optimized. The membrane consists of 1-octanol immobilized in the pores of a hollow fiber. As a driving force, a 30 V electrical field was applied to make the analyte migrate from sample solution with pH 3, through the supported liquid membrane into an acceptor solution with pH 10. Best preconcentration (enrichment factor >21) was obtained in extraction duration of 15 min. Effects of some solid nano-sorbents like carbon nanotubes and molecularly imprinted polymers on membrane performance and electromembrane extraction efficiency were evaluated. The method provided the linearity in the range 25-1000 ng/mL for tartrazine (R(2) > 0.9996) with repeatability range (RSD) between 3.8 and 8.5% (n = 3). The limits of detection and quantitation were 7.5 and 25 ng/mL, respectively. Finally, the method was applied to the determination and quantification of tartrazine from some food samples with relative recoveries in the range between 90 and 98%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Performance improvement of ionic surfactant flooding in carbonate rock samples by use of nanoparticles

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Ahmadi

    2016-07-01

    Full Text Available Abstract Various surfactants have been used in upstream petroleum processes like chemical flooding. Ultimately, the performance of these surfactants depends on their ability to reduce the interfacial tension between oil and water. The surfactant concentration in the aqueous solution decreases owing to the loss of the surfactant on the rock surface in the injection process. The main objective of this paper is to inhibit the surfactant loss by means of adding nanoparticles. Sodium dodecyl sulfate and silica nanoparticles were used as ionic surfactant and nanoparticles in our experiments, respectively. AEROSIL® 816 and AEROSIL® 200 are hydrophobic and hydrophilic nanoparticles. To determine the adsorption loss of the surfactant onto rock samples, a conductivity approach was used. Real carbonate rock samples were used as the solid phase in adsorption experiments. It should be noted that the rock samples were water wet. This paper describes how equilibrium adsorption was investigated by examining adsorption behavior in a system of carbonate sample (solid phase and surfactant solution (aqueous phase. The initial surfactant and nanoparticle concentrations were 500–5000 and 500–2000 ppm, respectively. The rate of surfactant losses was extremely dependent on the concentration of the surfactant in the system, and the adsorption of the surfactant decreased with an increase in the nanoparticle concentration. Also, the hydrophilic nanoparticles are more effective than the hydrophobic nanoparticles.

  18. Improved metamodel-based importance sampling for the performance assessment of radioactive waste repositories

    International Nuclear Information System (INIS)

    Cadini, F.; Gioletta, A.; Zio, E.

    2015-01-01

    In the context of a probabilistic performance assessment of a radioactive waste repository, the estimation of the probability of exceeding the dose threshold set by a regulatory body is a fundamental task. This may become difficult when the probabilities involved are very small, since the classically used sampling-based Monte Carlo methods may become computationally impractical. This issue is further complicated by the fact that the computer codes typically adopted in this context requires large computational efforts, both in terms of time and memory. This work proposes an original use of a Monte Carlo-based algorithm for (small) failure probability estimation in the context of the performance assessment of a near surface radioactive waste repository. The algorithm, developed within the context of structural reliability, makes use of an estimated optimal importance density and a surrogate, kriging-based metamodel approximating the system response. On the basis of an accurate analytic analysis of the algorithm, a modification is proposed which allows further reducing the computational efforts by a more effective training of the metamodel. - Highlights: • We tackle uncertainty propagation in a radwaste repository performance assessment. • We improve a kriging-based importance sampling for estimating failure probabilities. • We justify the modification by an analytic, comparative analysis of the algorithms. • The probability of exceeding dose thresholds in radwaste repositories is estimated. • The algorithm is further improved reducing the number of its free parameters

  19. Cultural influences on Facebook photographs.

    Science.gov (United States)

    Huang, Chih-Mao; Park, Denise

    2013-01-01

    Prior research in social psychology indicates that East Asians from collectivistic and interdependent sociocultural systems are more sensitive to contextual information than Westerners, whereas Westerners with individualistic and independent representation have a tendency to process focal and discrete attributes of the environment. Here we have demonstrated that such systematic cultural variations can also be observed in cyberspace, focusing on self-presentation of photographs on Facebook, the most popular worldwide online social network site. We examined cultural differences in face/frame ratios for Facebook profile photographs in two studies. For Study 1, 200 digital profile face photographs of active Facebook users were randomly selected from native and immigrant Taiwanese and Americans. For Study 2, 312 Facebook profiles of undergraduate students of six public universities in East Asia (Hong Kong, Singapore, and Taiwan) and the United States (California and Texas) were randomly selected. Overall, the two studies clearly showed that East Asian Facebook users are more likely to deemphasize their faces compared to Americans. Specifically, East Asians living in Hong Kong, Singapore, and Taiwan exhibited a predilection for context inclusiveness in their profile photographs, whereas Americans tended to prioritize their focal face at the expense of the background. Moreover, East Asian Facebook users had lower intensity of facial expression than Americans on their photographs. These results demonstrate marked cultural differences in context-inclusive styles versus object-focused styles between East Asian and American Facebook users. Our findings extend previous findings from the real world to cyberspace, and provide a novel approach to investigate cognition and behaviors across cultures by using Facebook as a data collection platform.

  20. Cultural influences on Facebook photographs

    Science.gov (United States)

    Huang, Chih-Mao; Park, Denise

    2012-01-01

    Prior research in social psychology indicates that East Asians from collectivistic and interdependent sociocultural systems are more sensitive to contextual information than Westerners, whereas Westerners with individualistic and independent representation have a tendency to process focal and discrete attributes of the environment. Here we have demonstrated that such systematic cultural variations can also be observed in cyberspace, focusing on self-presentation of photographs on Facebook, the most popular worldwide online social network site. We examined cultural differences in face/frame ratios for Facebook profile photographs in two studies. For Study 1, 200 digital profile face photographs of active Facebook users were randomly selected from native and immigrant Taiwanese and Americans. For Study 2, 312 Facebook profiles of undergraduate students of six public universities in East Asia (Hong Kong, Singapore, and Taiwan) and the United States (California and Texas) were randomly selected. Overall, the two studies clearly showed that East Asian Facebook users are more likely to deemphasize their faces compared to Americans. Specifically, East Asians living in Hong Kong, Singapore, and Taiwan exhibited a predilection for context inclusiveness in their profile photographs, whereas Americans tended to prioritize their focal face at the expense of the background. Moreover, East Asian Facebook users had lower intensity of facial expression than Americans on their photographs. These results demonstrate marked cultural differences in context-inclusive styles versus object-focused styles between East Asian and American Facebook users. Our findings extend previous findings from the real world to cyberspace, and provide a novel approach to investigate cognition and behaviors across cultures by using Facebook as a data collection platform. PMID:22468606

  1. Development of high performance liquid chromatography method for miconazole analysis in powder sample

    Science.gov (United States)

    Hermawan, D.; Suwandri; Sulaeman, U.; Istiqomah, A.; Aboul-Enein, H. Y.

    2017-02-01

    A simple high performance liquid chromatography (HPLC) method has been developed in this study for the analysis of miconazole, an antifungal drug, in powder sample. The optimized HPLC system using C8 column was achieved using mobile phase composition containing methanol:water (85:15, v/v), a flow rate of 0.8 mL/min, and UV detection at 220 nm. The calibration graph was linear in the range from 10 to 50 mg/L with r 2 of 0.9983. The limit of detection (LOD) and limit of quantitation (LOQ) obtained were 2.24 mg/L and 7.47 mg/L, respectively. The present HPLC method is applicable for the determination of miconazole in the powder sample with a recovery of 101.28 % (RSD = 0.96%, n = 3). The developed HPLC method provides short analysis time, high reproducibility and high sensitivity.

  2. Effect of the Target Motion Sampling temperature treatment method on the statistics and performance

    International Nuclear Information System (INIS)

    Viitanen, Tuomas; Leppänen, Jaakko

    2015-01-01

    Highlights: • Use of the Target Motion Sampling (TMS) method with collision estimators is studied. • The expected values of the estimators agree with NJOY-based reference. • In most practical cases also the variances of the estimators are unaffected by TMS. • Transport calculation slow-down due to TMS dominates the impact on figures-of-merit. - Abstract: Target Motion Sampling (TMS) is a stochastic on-the-fly temperature treatment technique that is being developed as a part of the Monte Carlo reactor physics code Serpent. The method provides for modeling of arbitrary temperatures in continuous-energy Monte Carlo tracking routines with only one set of cross sections stored in the computer memory. Previously, only the performance of the TMS method in terms of CPU time per transported neutron has been discussed. Since the effective cross sections are not calculated at any point of a transport simulation with TMS, reaction rate estimators must be scored using sampled cross sections, which is expected to increase the variances and, consequently, to decrease the figures-of-merit. This paper examines the effects of the TMS on the statistics and performance in practical calculations involving reaction rate estimation with collision estimators. Against all expectations it turned out that the usage of sampled response values has no practical effect on the performance of reaction rate estimators when using TMS with elevated basis cross section temperatures (EBT), i.e. the usual way. With 0 Kelvin cross sections a significant increase in the variances of capture rate estimators was observed right below the energy region of unresolved resonances, but at these energies the figures-of-merit could be increased using a simple resampling technique to decrease the variances of the responses. It was, however, noticed that the usage of the TMS method increases the statistical deviances of all estimators, including the flux estimator, by tens of percents in the vicinity of very

  3. Quantification of glibenclamide in cleaning samples of pharmaceutical equipment through high performance liquid chromatography

    International Nuclear Information System (INIS)

    Baeza Fonte, Alen Nils; Diaz Aguila, Elsa Eneida; Martinez Alfonso; Nancy

    2012-01-01

    to submit a selective analytical method for quantization of glibenclamide in cleaning samples of pharmaceutical equipment using high performance liquid chromatography. The mobile phase consisted of an equal mixing of acetonitrile/phosphate buffer KH 2 PO 4 ; with 0.037 mol/L concentration pH 5.25 and flow of 1.5 mL/min, in a Nucleosil 100 C8 column. Glibenclamide was injected with progesterone as internal standard and using an UV detector= 230 nm

  4. Heavenly bodies the photographer's guide to astrophotography

    CERN Document Server

    Krages, Esq, Bert P

    2003-01-01

    Detailing the photographic equipment and astronomical instruments needed to capture celestial images, this guide shows how astrophotography can be accessible to all photographers. Included is a detailed introduction to basic astronomy with information on mapping the sky, locating celestial bodies, and planning an expedition to photograph astronomical phenomena. Photographers learn how to determine the color sensitivity of various films and achieve the best possible exposure, how to ensure a captivating composition, and how commercially processed prints can support their artistic vision. Whethe

  5. Performance of the Brazilian laboratories on radionuclide analysis in environmental samples

    International Nuclear Information System (INIS)

    Vianna, Maria Elizabeth; Tauhata, Luiz; Oliveira, Josue P.; Oliveira, Antonio E.; Clain, Almir F.; Garcia, Luiz Carlos; Conceicao, Cirilo C. da

    1995-01-01

    The performance of fifteen Brazilian environmental radioanalytical laboratories was evaluated after their participation in nine intercomparison runs of the National Intercomparison Program, PNI, offered by the Instituto de Radioprotecao e Dosimetria, CNEN. A total of 549 radionuclide determinations in environmental samples were evaluated. The results classified as Good ranged from 56.4% for Alpha and Beta Gross determinations up to 84.9% for Gamma spectrometry determinations. These results shows that the best performance in radionuclide determination is reached in gamma spectrometry analyses and the worst in Alpha and Beta Gross determinations. This general behavior is similar to the one reached by other laboratories in international intercomparison programs. (author). 1 ref., 1 fig., 1 tab

  6. Automatic system for 3D reconstruction of the chick eye based on digital photographs.

    Science.gov (United States)

    Wong, Alexander; Genest, Reno; Chandrashekar, Naveen; Choh, Vivian; Irving, Elizabeth L

    2012-01-01

    The geometry of anatomical specimens is very complex and accurate 3D reconstruction is important for morphological studies, finite element analysis (FEA) and rapid prototyping. Although magnetic resonance imaging, computed tomography and laser scanners can be used for reconstructing biological structures, the cost of the equipment is fairly high and specialised technicians are required to operate the equipment, making such approaches limiting in terms of accessibility. In this paper, a novel automatic system for 3D surface reconstruction of the chick eye from digital photographs of a serially sectioned specimen is presented as a potential cost-effective and practical alternative. The system is designed to allow for automatic detection of the external surface of the chick eye. Automatic alignment of the photographs is performed using a combination of coloured markers and an algorithm based on complex phase order likelihood that is robust to noise and illumination variations. Automatic segmentation of the external boundaries of the eye from the aligned photographs is performed using a novel level-set segmentation approach based on a complex phase order energy functional. The extracted boundaries are sampled to construct a 3D point cloud, and a combination of Delaunay triangulation and subdivision surfaces is employed to construct the final triangular mesh. Experimental results using digital photographs of the chick eye show that the proposed system is capable of producing accurate 3D reconstructions of the external surface of the eye. The 3D model geometry is similar to a real chick eye and could be used for morphological studies and FEA.

  7. 31 CFR 91.10 - Photographs.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 1 2010-07-01 2010-07-01 false Photographs. 91.10 Section 91.10 Money and Finance: Treasury Regulations Relating to Money and Finance REGULATIONS GOVERNING CONDUCT IN OR ON THE BUREAU OF THE MINT BUILDINGS AND GROUNDS § 91.10 Photographs. The taking of photographs on...

  8. 22 CFR 51.26 - Photographs.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Photographs. 51.26 Section 51.26 Foreign Relations DEPARTMENT OF STATE NATIONALITY AND PASSPORTS PASSPORTS Application § 51.26 Photographs. The applicant must submit with his or her application photographs as prescribed by the Department that are a...

  9. Preserving local writers, genealogy, photographs, newspapers, and related materials

    CERN Document Server

    Smallwood, Carol

    2012-01-01

    Preserving Local Writers, Genealogy, Photographs, Newspapers, and Related Materials draws on the practical knowledge of archivists, preservationists, librarians, and others who share the goal of making local history accessible to future generations. Anyone who plans to start a local history project or preserve important historical materials will find plenty of tips, techniques, sample documents, project ideas, and inspiration in its pages.

  10. How to Perform Precise Soil and Sediment Sampling? One solution: The Fine Increment Soil Collector (FISC)

    International Nuclear Information System (INIS)

    Mabit, L.; Toloza, A.; Meusburger, K.; Alewell, C.; Iurian, A-R.; Owens, P.N.

    2014-01-01

    Soil and sediment related research for terrestrial agrienvironmental assessments requires accurate depth incremental sampling to perform detailed analysis of physical, geochemical and biological properties of soil and exposed sediment profiles. Existing equipment does not allow collecting soil/sediment increments at millimetre resolution. The Fine Increment Soil Collector (FISC), developed by the SWMCN Laboratory, allows much greater precision in incremental soil/sediment sampling. It facilitates the easy recovery of collected material by using a simple screw-thread extraction system (see Figure 1). The FISC has been designed specifically to enable standardized scientific investigation of shallow soil/sediment samples. In particular, applications have been developed in two IAEA Coordinated Research Projects (CRPs): CRP D1.20.11 on “Integrated Isotopic Approaches for an Area-wide Precision Conservation to Control the Impacts of Agricultural Practices on Land Degradation and Soil Erosion” and CRP D1.50.15 on “Response to Nuclear Emergencies Affecting Food and Agriculture.”

  11. Performance evaluation of an importance sampling technique in a Jackson network

    Science.gov (United States)

    brahim Mahdipour, E.; Masoud Rahmani, Amir; Setayeshi, Saeed

    2014-03-01

    Importance sampling is a technique that is commonly used to speed up Monte Carlo simulation of rare events. However, little is known regarding the design of efficient importance sampling algorithms in the context of queueing networks. The standard approach, which simulates the system using an a priori fixed change of measure suggested by large deviation analysis, has been shown to fail in even the simplest network settings. Estimating probabilities associated with rare events has been a topic of great importance in queueing theory, and in applied probability at large. In this article, we analyse the performance of an importance sampling estimator for a rare event probability in a Jackson network. This article carries out strict deadlines to a two-node Jackson network with feedback whose arrival and service rates are modulated by an exogenous finite state Markov process. We have estimated the probability of network blocking for various sets of parameters, and also the probability of missing the deadline of customers for different loads and deadlines. We have finally shown that the probability of total population overflow may be affected by various deadline values, service rates and arrival rates.

  12. Comparative Performance of PLZT and PVDF Pyroelectric Sensors Used to the Thermal Characterization of Liquid Samples

    Directory of Open Access Journals (Sweden)

    Gemima Lara Hernandez

    2013-01-01

    Full Text Available Among the photothermal methods, the photopyroelectric (PPE technique is a suitable method to determine thermal properties of different kinds of samples ranging from solids to liquids and gases. Polyvinylidene difluoride (PVDF is one of the most frequently used pyroelectric sensors in PPE technique but has the disadvantage that it can be easily deformed by the sample weight. This deformation could add a piezoelectric effect to the thermal parameters assessment; also PVDF has a narrow temperature operation range when compared with ceramic pyroelectric sensors. In order to minimize possible piezoelectric effects due to sensor deformation, a ceramic of lanthanum modified lead zirconate (PLZT was used as pyroelectric sensor in the PPE technique. Then, thermal diffusivity of some liquid samples was measured, by using the PPE configuration that denominated the thermal wave resonator cavity (TWRC, with a PLZT ceramic as pyroelectric detector. The performance obtained with the proposed ceramic in the TWRC configuration was compared with that obtained with PVDF by using the same configuration.

  13. How to Perform Precise Soil and Sediment Sampling? One solution: The Fine Increment Soil Collector (FISC)

    Energy Technology Data Exchange (ETDEWEB)

    Mabit, L.; Toloza, A. [Soil and Water Management and Crop Nutrition Laboratory, IAEA, Seibersdorf (Austria); Meusburger, K.; Alewell, C. [Environmental Geosciences, Department of Environmental Sciences, University of Basel, Basel (Switzerland); Iurian, A-R. [Babes-Bolyai University, Faculty of Environmental Science and Engineering, Cluj-Napoca (Romania); Owens, P. N. [Environmental Science Program and Quesnel River Research Centre, University of Northern British Columbia, Prince George, British Columbia (Canada)

    2014-07-15

    Soil and sediment related research for terrestrial agrienvironmental assessments requires accurate depth incremental sampling to perform detailed analysis of physical, geochemical and biological properties of soil and exposed sediment profiles. Existing equipment does not allow collecting soil/sediment increments at millimetre resolution. The Fine Increment Soil Collector (FISC), developed by the SWMCN Laboratory, allows much greater precision in incremental soil/sediment sampling. It facilitates the easy recovery of collected material by using a simple screw-thread extraction system (see Figure 1). The FISC has been designed specifically to enable standardized scientific investigation of shallow soil/sediment samples. In particular, applications have been developed in two IAEA Coordinated Research Projects (CRPs): CRP D1.20.11 on “Integrated Isotopic Approaches for an Area-wide Precision Conservation to Control the Impacts of Agricultural Practices on Land Degradation and Soil Erosion” and CRP D1.50.15 on “Response to Nuclear Emergencies Affecting Food and Agriculture.”.

  14. Tribological performance of titanium samples oxidized by fs-laser radiation, thermal heating, or electrochemical anodization

    Science.gov (United States)

    Kirner, S. V.; Slachciak, N.; Elert, A. M.; Griepentrog, M.; Fischer, D.; Hertwig, A.; Sahre, M.; Dörfel, I.; Sturm, H.; Pentzien, S.; Koter, R.; Spaltmann, D.; Krüger, J.; Bonse, J.

    2018-04-01

    Commercial grade-1 titanium samples (Ti, 99.6%) were treated using three alternative methods, (i) femtosecond laser processing, (ii) thermal heat treatment, and (iii) electrochemical anodization, respectively, resulting in the formation of differently conditioned superficial titanium oxide layers. The laser processing (i) was carried out by a Ti:sapphire laser (pulse duration 30 fs, central wavelength 790 nm, pulse repetition rate 1 kHz) in a regime of generating laser-induced periodic surface structures (LIPSS). The experimental conditions (laser fluence, spatial spot overlap) were optimized in a sample-scanning setup for the processing of several square-millimeters large surface areas covered homogeneously by these nanostructures. The differently oxidized titanium surfaces were characterized by optical microscopy, micro Raman spectroscopy, variable angle spectroscopic ellipsometry, and instrumented indentation testing. The tribological performance was characterized in the regime of mixed friction by reciprocating sliding tests against a sphere of hardened steel in fully formulated engine oil as lubricant. The specific tribological performance of the differently treated surfaces is discussed with respect to possible physical and chemical mechanisms.

  15. Performance evaluation of continuous blood sampling system for PET study. Comparison of three detector-systems

    CERN Document Server

    Matsumoto, K; Sakamoto, S; Senda, M; Yamamoto, S; Tarutani, K; Minato, K

    2002-01-01

    To measure cerebral blood flow with sup 1 sup 5 O PET, it is necessary to measure the time course of arterial blood radioactivity. We examined the performance of three different types of continuous blood sampling system. Three kinds of continuous blood sampling system were used: a plastic scintillator-based beta detector (conventional beta detector (BETA)), a bismuth germinate (BGO)-based coincidence gamma detector (Pico-count flow-through detector (COINC)) and a Phoswich detector (PD) composed by a combination of plastic scintillator and BGO scintillator. Performance of these systems was evaluated for absolute sensitivity, count rate characteristic, sensitivity to background gamnra photons, and reproducibility for nylon tube geometry. The absolute sensitivity of the PD was 0.21 cps/Bq for sup 6 sup 8 Ga positrons at the center of the detector. This was approximately three times higher than BETA, two times higher than COINC. The value measured with BETA was stable, even when background radioactivity was incre...

  16. The role of anxiety symptoms in school performance in a community sample of children and adolescents

    Directory of Open Access Journals (Sweden)

    D'Arrigo Valentina

    2007-12-01

    Full Text Available Abstract Background Anxiety symptoms are relatively common among children and adolescents and can interfere with functioning. The prevalence of anxiety and the relationship between anxiety and school performance were examined among elementary, middle, and high school students. Methods Samples of elementary (N = 131, age 8–10 years, middle (N = 267, age 11–13 years, and high school (N = 80, age 14–16 years children were recruited from four public schools in a predominantly middle-class community in Catania, Italy. Children completed the Multidimensional Anxiety Scale for Children (MASC. T-scores were computed for the MASC total scores, and considered to be in the anxious range if 65 or above. Current academic grades were obtained from school records. Results Of the 478 children, 35 (7.3% had a MASC T-score in the anxious range. The rate of children in the anxious range was 2.3% in elementary, 7.9% in middle, and 15.9% in high school (χ2 = 7.8, df = 2, p 2 = 11.68, df = 2, p Conclusion In this community sample of children and adolescents attending elementary through high school, the prevalence of abnormally high self-reported levels of anxiety increased in frequency with age and was negatively associated with school performance.

  17. Can you estimate body composition in dogs from photographs?

    Science.gov (United States)

    Gant, Poppy; Holden, Shelley L; Biourge, Vincent; German, Alexander J

    2016-01-20

    A validated method for assessing the visual characteristics of body condition from photographs (vBCS), would be a useful initial screening tool for client-owned dogs. In this retrospective study, photographs taken before and after weight loss from 155 overweight and obese dogs attending a weight management referral clinic were used in designing and testing the feasibility of vBCS. Observers with a range of experience examined the photographs, and estimated body condition indirectly (vBCS) using three different methods. In the first method (vBCSmeasured), the ratio of abdominal width to thoracic width (A:T) was measured, and cut-points used to determine body condition; the second method (iBCSsubjective) involved semi-quantitative examination using visual descriptors of BCS; the third (vBCSadjusted) was a combined approach whereby A:T ratio was first determined, and the final score modified if necessary after assessing photographs. When an experienced observer performed vBCS, there were moderate-to-good associations between body fat (measured by dual-energy X-ray absorptiometry) and the three vBCS methods (median Rs: 0.51-0.75; P  0.05 for all). Compared with ideal weight and obese dogs, errors in assessing body condition were more common for overweight dogs (e.g. BCS 6-7/9, P photographs, but performance varies amongst observers.

  18. Mapping species distributions with MAXENT using a geographically biased sample of presence data: a performance assessment of methods for correcting sampling bias.

    Science.gov (United States)

    Fourcade, Yoan; Engler, Jan O; Rödder, Dennis; Secondi, Jean

    2014-01-01

    MAXENT is now a common species distribution modeling (SDM) tool used by conservation practitioners for predicting the distribution of a species from a set of records and environmental predictors. However, datasets of species occurrence used to train the model are often biased in the geographical space because of unequal sampling effort across the study area. This bias may be a source of strong inaccuracy in the resulting model and could lead to incorrect predictions. Although a number of sampling bias correction methods have been proposed, there is no consensual guideline to account for it. We compared here the performance of five methods of bias correction on three datasets of species occurrence: one "virtual" derived from a land cover map, and two actual datasets for a turtle (Chrysemys picta) and a salamander (Plethodon cylindraceus). We subjected these datasets to four types of sampling biases corresponding to potential types of empirical biases. We applied five correction methods to the biased samples and compared the outputs of distribution models to unbiased datasets to assess the overall correction performance of each method. The results revealed that the ability of methods to correct the initial sampling bias varied greatly depending on bias type, bias intensity and species. However, the simple systematic sampling of records consistently ranked among the best performing across the range of conditions tested, whereas other methods performed more poorly in most cases. The strong effect of initial conditions on correction performance highlights the need for further research to develop a step-by-step guideline to account for sampling bias. However, this method seems to be the most efficient in correcting sampling bias and should be advised in most cases.

  19. Photographs of the southern heavens

    CERN Document Server

    West, R M

    1975-01-01

    The 1 m Schmidt telescope of the European Southern Observatory (ESO) has been used for a number of sky surveys. In particular a main task has been an examination of the southern night sky between declinations of -20 degrees and -90 degrees . This exercise is known as the ESO(B) Survey (or Quick Blue Survey); some of the more interesting results are shown and are briefly discussed. The photographic plates used were Kodak II a-o. There are photographs of the two Magellanic Clouds and of the galaxy NGC 1313 and the globular cluster NGC 6752. A spectrogram of our Galaxy for wavelengths in the band 3900 A to 4900 A, taken with the telescope's large objective prism is also shown. (0 refs).

  20. Chimpanzee responding during matching to sample: control by exclusion.

    OpenAIRE

    Beran, Michael J; Washburn, David A

    2002-01-01

    Three chimpanzees performed a computerized matching-to-sample task in which samples were photographs of items and comparison stimuli were geometric symbols called lexigrams. In Experiment 1, samples were either defined (i.e., they represented items that were associated already with a specific lexigram label by the chimpanzees) or undefined (i.e., they did not have an already learned association with a specific lexigram). On each trial, the foil (incorrect) comparison could be either a defined...

  1. Automated cell counts on CSF samples: A multicenter performance evaluation of the GloCyte system.

    Science.gov (United States)

    Hod, E A; Brugnara, C; Pilichowska, M; Sandhaus, L M; Luu, H S; Forest, S K; Netterwald, J C; Reynafarje, G M; Kratz, A

    2018-02-01

    Automated cell counters have replaced manual enumeration of cells in blood and most body fluids. However, due to the unreliability of automated methods at very low cell counts, most laboratories continue to perform labor-intensive manual counts on many or all cerebrospinal fluid (CSF) samples. This multicenter clinical trial investigated if the GloCyte System (Advanced Instruments, Norwood, MA), a recently FDA-approved automated cell counter, which concentrates and enumerates red blood cells (RBCs) and total nucleated cells (TNCs), is sufficiently accurate and precise at very low cell counts to replace all manual CSF counts. The GloCyte System concentrates CSF and stains RBCs with fluorochrome-labeled antibodies and TNCs with nucleic acid dyes. RBCs and TNCs are then counted by digital image analysis. Residual adult and pediatric CSF samples obtained for clinical analysis at five different medical centers were used for the study. Cell counts were performed by the manual hemocytometer method and with the GloCyte System following the same protocol at all sites. The limits of the blank, detection, and quantitation, as well as precision and accuracy of the GloCyte, were determined. The GloCyte detected as few as 1 TNC/μL and 1 RBC/μL, and reliably counted as low as 3 TNCs/μL and 2 RBCs/μL. The total coefficient of variation was less than 20%. Comparison with cell counts obtained with a hemocytometer showed good correlation (>97%) between the GloCyte and the hemocytometer, including at very low cell counts. The GloCyte instrument is a precise, accurate, and stable system to obtain red cell and nucleated cell counts in CSF samples. It allows for the automated enumeration of even very low cell numbers, which is crucial for CSF analysis. These results suggest that GloCyte is an acceptable alternative to the manual method for all CSF samples, including those with normal cell counts. © 2017 John Wiley & Sons Ltd.

  2. The Determination of Polyethylene Glycol in Untreated Urine Samples by High Performance Liquid Chromatography for Intestinal Permeability Studies

    DEFF Research Database (Denmark)

    Larsen, Elfinn; Pedersen, Walther Batsberg; Philipsen, E.

    1985-01-01

    Polyethylene glycol in urine samples has been investigated by high performance liquid chromatography. The molecular weights ranged from 634 to 1338. The urine samples were applied to the chromatographic system without any pre-treatment. For samples with a concentration of 0.2% polyethylene glycol...

  3. Blood pressure interacts with APOE ε4 to predict memory performance in a midlife sample.

    Science.gov (United States)

    Oberlin, Lauren E; Manuck, Stephen B; Gianaros, Peter J; Ferrell, Robert E; Muldoon, Matthew F; Jennings, J Richard; Flory, Janine D; Erickson, Kirk I

    2015-09-01

    Elevated blood pressure and the Apolipoprotein ε4 allele (APOE ε4) are independent risk factors for Alzheimer's disease. We sought to determine whether the combined presence of the APOE ε4 allele and elevated blood pressure is associated with lower cognitive performance in cognitively healthy middle-aged adults. A total of 975 participants aged 30-54 (mean age = 44.47) were genotyped for APOE. Cardiometabolic risk factors including blood pressure, lipids, and glucose were assessed and cognitive function was measured using the Trail Making Test and the Visual Reproduction and Logical Memory subtests from the Wechsler Memory Scale. Multivariable regression analysis showed that the association between APOE ε4 and episodic memory performance varied as a function of systolic blood pressure (SBP), such that elevated SBP was predictive of poorer episodic memory performance only in APOE ε4 carriers (β = -.092; t = -2.614; p = .009). Notably, this association was apparent at prehypertensive levels (≥130 mmHg), even after adjusting for physical activity, depression, smoking, and other cardiometabolic risk factors. The joint presence of APOE ε4 and elevated SBP, even at prehypertensive levels, is associated with lower cognitive performance in healthy, middle-aged adults. Results of this study suggest that the combination of APOE ε4 and elevated SBP may synergistically compromise memory function well before the appearance of clinically significant impairments. Interventions targeting blood pressure control in APOE ε4 carriers during midlife should be studied as a possible means to reduce the risk of cognitive decline in genetically susceptible samples. (c) 2015 APA, all rights reserved).

  4. A simple high performance liquid chromatography method for analyzing paraquat in soil solution samples.

    Science.gov (United States)

    Ouyang, Ying; Mansell, Robert S; Nkedi-Kizza, Peter

    2004-01-01

    A high performance liquid chromatography (HPLC) method with UV detection was developed to analyze paraquat (1,1'-dimethyl-4,4'-dipyridinium dichloride) herbicide content in soil solution samples. The analytical method was compared with the liquid scintillation counting (LSC) method using 14C-paraquat. Agreement obtained between the two methods was reasonable. However, the detection limit for paraquat analysis was 0.5 mg L(-1) by the HPLC method and 0.05 mg L(-1) by the LSC method. The LSC method was, therefore, 10 times more precise than the HPLC method for solution concentrations less than 1 mg L(-1). In spite of the high detection limit, the UC (nonradioactive) HPLC method provides an inexpensive and environmentally safe means for determining paraquat concentration in soil solution compared with the 14C-LSC method.

  5. Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors

    International Nuclear Information System (INIS)

    Judenhofer, Martin S; Pichler, Bernd J; Cherry, Simon R

    2005-01-01

    Detectors used for positron emission tomography (PET) provide fast, randomly distributed signals that need to be digitized for further processing. One possibility is to sample the signals at the peak initiated by a trigger from a constant fraction discriminator (CFD). For PET detectors, simultaneous acquisition of many channels is often important. To develop and evaluate novel PET detectors, a flexible, relatively low cost and high performance laboratory data acquisition (DAQ) system is therefore required. The use of dedicated DAQ systems, such as a multi-channel analysers (MCAs) or continuous sampling boards at high rates, is expensive. This work evaluates the suitability of well-priced peripheral component interconnect (PCI)-based 8-channel DAQ boards (PD2-MFS-8 2M/14 and PD2-MFS-8-500k/14, United Electronic Industries Inc., Canton, MA, USA) for signal acquisition from novel PET detectors. A software package was developed to access the board, measure basic board parameters, and to acquire, visualize, and analyse energy spectra and position profiles from block detectors. The performance tests showed that the boards input linearity is >99.2% and the standard deviation is 22 Na source was 14.9% (FWHM) at 511 keV and is slightly better than the result obtained with a high-end single channel MCA (8000A, Amptek, USA) using the same detector (16.8%). The crystals (1.2 x 1.2 x 12 mm 3 ) within a 9 x 9 LSO block detector could be clearly separated in an acquired position profile. Thus, these boards are well suited for data acquisition with novel detectors developed for nuclear imaging

  6. Performance of laboratories analysing welding fume on filter samples: results from the WASP proficiency testing scheme.

    Science.gov (United States)

    Stacey, Peter; Butler, Owen

    2008-06-01

    This paper emphasizes the need for occupational hygiene professionals to require evidence of the quality of welding fume data from analytical laboratories. The measurement of metals in welding fume using atomic spectrometric techniques is a complex analysis often requiring specialist digestion procedures. The results from a trial programme testing the proficiency of laboratories in the Workplace Analysis Scheme for Proficiency (WASP) to measure potentially harmful metals in several different types of welding fume showed that most laboratories underestimated the mass of analyte on the filters. The average recovery was 70-80% of the target value and >20% of reported recoveries for some of the more difficult welding fume matrices were welding fume trial filter samples. Consistent rather than erratic error predominated, suggesting that the main analytical factor contributing to the differences between the target values and results was the effectiveness of the sample preparation procedures used by participating laboratories. It is concluded that, with practice and regular participation in WASP, performance can improve over time.

  7. Episodic memory change in late adulthood: generalizability across samples and performance indices.

    Science.gov (United States)

    Dixon, Roger A; Wahlin, Ake; Maitland, Scott B; Hultsch, David F; Hertzog, Christopher; Bäckman, Lars

    2004-07-01

    Younger adults recall more information from episodic memory tasks than do older adults. Because longitudinal studies are rare and often incompatible, the extent of actual late-life memory change is not well established. We assemble two different longitudinal samples of normal older adults, each of which is tested twice at a 3-year interval, using a large battery of episodic memory indicators. Together, two-wave data from both the Victoria Longitudinal Study in Canada (n = 400) and the Kungsholmen Project in Sweden (n = 168) cover a 40-year span of adulthood, ranging from 54 to 94 years of age. Principal memory tasks include categorizable word lists, story recall, and random word lists, as well as indicators of cognitive support. Overall, an examination of performance on sets of common and complementary episodic tasks reveals that, for both samples, actual 3-year changes are modest and that, when decline occurs, it is gradual. The exception-greater decline for more supported tasks-suggests that these may be especially sensitive to late-life changes.

  8. Analysis of Fluconazole in Human Urine Sample by High Performance Liquid Chromatography Method

    International Nuclear Information System (INIS)

    Hermawan, D; Ali, N A Md; Ibrahim, W A Wan; Sanagi, M M

    2013-01-01

    A method for determination of fluconazole, antifungal drug in human urine by using reversed-phased high performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detector was developed. Optimization HPLC conditions were carried out by changing the flow rate and composition of mobile phase. The optimum separation conditions at a flow rate 0.85 mL/min with a composition of mobile phase containing methanol:water (70:30, v/v) with UV detection at a wavelength 254 nm was able to analyze fluconazole within 3 min. The excellent linearity was obtained in the range of concentration 1 to 10 μg/mL with r 2 = 0.998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.39 μg/mL and 1.28 μg/mL, respectively. Solid phase extraction (SPE) method using octadecylsilane (C18) as a sorbent was used to clean-up and pre-concentrated of the urine sample prior to HPLC analysis. The average recoveries of fluconazole in spiked urine sample was 72.4% with RSD of 3.21% (n=3).

  9. Children's Recognition of Emotional Facial Expressions Through Photographs and Drawings.

    Science.gov (United States)

    Brechet, Claire

    2017-01-01

    The author's purpose was to examine children's recognition of emotional facial expressions, by comparing two types of stimulus: photographs and drawings. The author aimed to investigate whether drawings could be considered as a more evocative material than photographs, as a function of age and emotion. Five- and 7-year-old children were presented with photographs and drawings displaying facial expressions of 4 basic emotions (i.e., happiness, sadness, anger, and fear) and were asked to perform a matching task by pointing to the face corresponding to the target emotion labeled by the experimenter. The photographs we used were selected from the Radboud Faces Database and the drawings were designed on the basis of both the facial components involved in the expression of these emotions and the graphic cues children tend to use when asked to depict these emotions in their own drawings. Our results show that drawings are better recognized than photographs, for sadness, anger, and fear (with no difference for happiness, due to a ceiling effect). And that the difference between the 2 types of stimuli tends to be more important for 5-year-olds compared to 7-year-olds. These results are discussed in view of their implications, both for future research and for practical application.

  10. Study of the radioactivity of rocks by the photographic method

    Energy Technology Data Exchange (ETDEWEB)

    Picciotto, E E

    1949-08-16

    The use of photographic plates, and especially of the new Ilford and Kodak plates, in nuclear physics is briefly described. In particular, the application of these methods to the study of the radioactivity of rocks is discussed. In a series of studies made by the authors, the photographic plates were placed in close contact with a thin, highly polished sheet of the rock sample and then developed under specified conditions. This method was used to determine the concentration of U and Th in two radioactive rock samples and the results are given. The samples were then reduced to powder form and the concentrations were again determined. Work on dissolved samples has not yet been completed. In conclusion, the relative merits of these different techniques are indicated.

  11. The Role of Clarity and Blur in Guiding Visual Attention in Photographs

    Science.gov (United States)

    Enns, James T.; MacDonald, Sarah C.

    2013-01-01

    Visual artists and photographers believe that a viewer's gaze can be guided by selective use of image clarity and blur, but there is little systematic research. In this study, participants performed several eye-tracking tasks with the same naturalistic photographs, including recognition memory for the entire photo, as well as recognition memory…

  12. Effects of photographic distance on tree crown atributes calculated using urbancrowns image analysis software

    Science.gov (United States)

    Mason F. Patterson; P. Eric Wiseman; Matthew F. Winn; Sang-mook Lee; Philip A. Araman

    2011-01-01

    UrbanCrowns is a software program developed by the USDA Forest Service that computes crown attributes using a side-view digital photograph and a few basic field measurements. From an operational standpoint, it is not known how well the software performs under varying photographic conditions for trees of diverse size, which could impact measurement reproducibility and...

  13. Glass sample preparation and performance investigations. [solar x-ray imager

    Science.gov (United States)

    Johnson, R. Barry

    1992-01-01

    This final report details the work performed under this delivery order from April 1991 through April 1992. The currently available capabilities for integrated optical performance modeling at MSFC for large and complex systems such as AXAF were investigated. The Integrated Structural Modeling (ISM) program developed by Boeing for the U.S. Air Force was obtained and installed on two DECstations 5000 at MSFC. The structural, thermal and optical analysis programs available in ISM were evaluated. As part of the optomechanical engineering activities, technical support was provided in the design of support structure, mirror assembly, filter wheel assembly and material selection for the Solar X-ray Imager (SXI) program. As part of the fabrication activities, a large number of zerodur glass samples were prepared in different sizes and shapes for acid etching, coating and polishing experiments to characterize the subsurface damage and stresses produced by the grinding and polishing operations. Various optical components for AXAF video microscope and the x-ray test facility were also fabricated. A number of glass fabrication and test instruments such as a scatter plate interferometer, a gravity feed saw and some phenolic cutting blades were fabricated, integrated and tested.

  14. The role of anxiety symptoms in school performance in a community sample of children and adolescents.

    Science.gov (United States)

    Mazzone, Luigi; Ducci, Francesca; Scoto, Maria Cristina; Passaniti, Eleonora; D'Arrigo, Valentina Genitori; Vitiello, Benedetto

    2007-12-05

    Anxiety symptoms are relatively common among children and adolescents and can interfere with functioning. The prevalence of anxiety and the relationship between anxiety and school performance were examined among elementary, middle, and high school students. Samples of elementary (N = 131, age 8-10 years), middle (N = 267, age 11-13 years), and high school (N = 80, age 14-16 years) children were recruited from four public schools in a predominantly middle-class community in Catania, Italy. Children completed the Multidimensional Anxiety Scale for Children (MASC). T-scores were computed for the MASC total scores, and considered to be in the anxious range if 65 or above. Current academic grades were obtained from school records. Of the 478 children, 35 (7.3%) had a MASC T-score in the anxious range. The rate of children in the anxious range was 2.3% in elementary, 7.9% in middle, and 15.9% in high school (chi2 = 7.8, df = 2, p children and adolescents attending elementary through high school, the prevalence of abnormally high self-reported levels of anxiety increased in frequency with age and was negatively associated with school performance.

  15. The performance of the Mini-Cog in a sample of low educational level elderly.

    Science.gov (United States)

    Ribeiro Filho, Sergio Telles; Lourenço, Roberto Alves

    2009-01-01

    To study the criterion validity of the Mini-Cog in low educational level elderly. Design: Cross-sectional and validation design. Setting: Policlínica Piquet Carneiro, an outpatient unit of Rio de Janeiro State University Hospital, in Brazil. Participants: A convenient sample consisting of 306 individuals, 65 yrs or older, selected from April 8 th to July 15 th , 2002. All participants underwent comprehensive geriatric evaluations which included the Mini-Mental State Examination (MMSE) and the cognitive part of the Cambridge Examination for Mental Disorders of the Elderly - Revised (CAMCOG-R). They were classified as demented or non-demented (DSM-IV). A post-hoc analysis was performed on the data from the 3 word recall test of the MMSE, and the Clock Drawing Test from the CAMCOG-R, and respective scores were added and interpreted in accordance with the Mini-Cog protocol. 293 individuals completed all the study steps; 211 had 4 or less years of schooling and were included in the data analysis. 32% had dementia. Mini-Cog sensitivity and specificity was consistently low independently of the different cut-off points considered. The best performance was found at the cut-off point of 2/3 which yielded sensitivity and specificity of 60% and 65%, respectively. The Mini-Cog is not a good cognitive screening tool for individuals with less than five years of formal education.

  16. The performance of the Mini-Cog in a sample of low educational level elderly

    Directory of Open Access Journals (Sweden)

    Sergio Telles Ribeiro Filho

    Full Text Available Abstract Objectives: To study the criterion validity of the Mini-Cog in low educational level elderly. Design: Cross-sectional and validation design. Setting: Policlínica Piquet Carneiro, an outpatient unit of Rio de Janeiro State University Hospital, in Brazil. Participants: A convenient sample consisting of 306 individuals, 65 yrs or older, selected from April 8th to July 15th, 2002. Methods: All participants underwent comprehensive geriatric evaluations which included the Mini-Mental State Examination (MMSE and the cognitive part of the Cambridge Examination for Mental Disorders of the Elderly - Revised (CAMCOG-R. They were classified as demented or non-demented (DSM-IV. A post-hoc analysis was performed on the data from the 3 word recall test of the MMSE, and the Clock Drawing Test from the CAMCOG-R, and respective scores were added and interpreted in accordance with the Mini-Cog protocol. Results: 293 individuals completed all the study steps; 211 had 4 or less years of schooling and were included in the data analysis. 32% had dementia. Mini-Cog sensitivity and specificity was consistently low independently of the different cut-off points considered. The best performance was found at the cut-off point of 2/3 which yielded sensitivity and specificity of 60% and 65%, respectively. Conclusion: The Mini-Cog is not a good cognitive screening tool for individuals with less than five years of formal education.

  17. Procrastination, Flow, and Academic Performance in Real Time Using the Experience Sampling Method.

    Science.gov (United States)

    Sumaya, Isabel C; Darling, Emily

    2018-01-01

    The authors' aim was to first provide an alternative methodology in the assessment of procrastination and flow that would not reply on retrospective or prospective self-reports. Using real-time assessment of both procrastination and flow, the authors investigated how these factors impact academic performance by using the Experience Sampling Method. They assessed flow by measuring student self-reported skill versus challenge, and procrastination by measuring the days to completion of an assignment. Procrastination and flow were measured for six days before a writing assignment due date while students (n = 14) were enrolled in a research methods course. Regardless of status of flow, both the nonflow and flow groups showed high levels of procrastination. Students who experienced flow as they worked on their paper, in real time, earned significantly higher grades (M = 3.05 ± 0.30: an average grade of B) as compared with the nonflow group (M = 1.16 ± 0.33: an average grade of D; p = .007). Additionally, students experiencing flow were more accurate in predicting their grade (difference scores, flow M = 0.12 ± 0.33 vs. nonflow M = 1.39 ± 0.29; p = .015). Students in the nonflow group were nearly a grade and a half off in their prediction of their grade on the paper. To the authors' knowledge, the study is the first to provide experimental evidence showing differences in academic performance between students experiencing flow and nonflow students.

  18. Expressing analytical performance from multi-sample evaluation in laboratory EQA.

    Science.gov (United States)

    Thelen, Marc H M; Jansen, Rob T P; Weykamp, Cas W; Steigstra, Herman; Meijer, Ron; Cobbaert, Christa M

    2017-08-28

    To provide its participants with an external quality assessment system (EQAS) that can be used to check trueness, the Dutch EQAS organizer, Organization for Quality Assessment of Laboratory Diagnostics (SKML), has innovated its general chemistry scheme over the last decade by introducing fresh frozen commutable samples whose values were assigned by Joint Committee for Traceability in Laboratory Medicine (JCTLM)-listed reference laboratories using reference methods where possible. Here we present some important innovations in our feedback reports that allow participants to judge whether their trueness and imprecision meet predefined analytical performance specifications. Sigma metrics are used to calculate performance indicators named 'sigma values'. Tolerance intervals are based on both Total Error allowable (TEa) according to biological variation data and state of the art (SA) in line with the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Milan consensus. The existing SKML feedback reports that express trueness as the agreement between the regression line through the results of the last 12 months and the values obtained from reference laboratories and calculate imprecision from the residuals of the regression line are now enriched with sigma values calculated from the degree to which the combination of trueness and imprecision are within tolerance limits. The information and its conclusion to a simple two-point scoring system are also graphically represented in addition to the existing difference plot. By adding sigma metrics-based performance evaluation in relation to both TEa and SA tolerance intervals to its EQAS schemes, SKML provides its participants with a powerful and actionable check on accuracy.

  19. Performance of an app measuring spot quality in dried blood spot sampling

    NARCIS (Netherlands)

    Veenhof, Herman

    2016-01-01

    Introduction: The Dried Blood Spot sampling (DBS) method gives patients and health care workers the opportunity for remote sampling using a drop of blood from a fingerprick on a sampling card which can be send to the laboratory by mail. Laboratory analysts frequently reject DBS samples because of

  20. Quantification of LSD in illicit samples by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Pablo Alves Marinho

    2010-12-01

    Full Text Available In the present study, a method using high performance liquid chromatography to quantify LSD, in blotter papers seized in Minas Gerais, was optimized and validated. Linearity, precision, recovery, limits of detection and quantification, and selectivity were the parameters used to evaluate performance. The samples were extracted with methanol:water (1: 1 in an ultra-sound bath. The linearity between 0.05 and 20.00 μg/mL (0.5 and 200.0μg of LSD/blotter was observed with satisfactory mean intra and inter assay precision (RSDr = 4.4% and RSD R = 6.4%, respectively and with mean recoveries of 83.4% and 84.9% to the levels of 1.00 and 20.00 μg/mL (10 and 200μg LSD/blotter. The limits of detection and quantification were 0.01 and 0.05 μg/mL, respectively (0.1 and 0.5 μg of LSD/blotter. The samples of blotters (n =22 were analyzed and the mean value of 67.55 μg of LSD/blotter (RSD=27.5% was found. Thus, the method used showed satisfactory analytical performance, and proved suitable as an analytical tool for LSD determination in illicit samples seized by police forces.No presente trabalho, um método utilizando cromatografia líquida de alta eficiência foi otimizado e validado para quantificar o LSD em selos apreendidos em Minas Gerais. A linearidade, precisão, recuperação, limites de detecção e quantificação e seletividade foram os parâmetros de desempenho avaliados. As amostras foram extraídas com metanol: água (1:1 em banho de ultra-som. A linearidade entre 0,05 a 20,00 mg/mL (0,5 a 200 μg LSD/blotter foi observada com precisão média, intra e inter ensaio, satisfatória (RSDr = 4,4% e RSD R = 6,4%, respectivamente e com recuperações médias de 83,4% e 84,9% para os níveis de LSD de 1,00 e 20,00 mg/mL (10 e 200 μg LSD/selo. Os limites de detecção e quantificação encontrados foram de 0,01 e 0,05 mg/mL, respectivamente (0,1 e 0,5 μg LSD/selo. As amostras de selos (n = 22 foram analisadas e o valor médio encontrado foi de 67

  1. High performance liquid chromatography--atomic fluorescence spectrometric determination of arsenic species in beer samples

    International Nuclear Information System (INIS)

    Melo Coelho, N.M.; Parrilla, Carmen; Cervera, M.L.; Pastor, A.; Guardia, M. de la

    2003-01-01

    A method has been developed for the direct determination of As(III), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and As(V) in beers by hydride generation--atomic fluorescence spectrometry after separation of arsenic species by high performance liquid chromatography. Compounds were separated by anion-exchange chromatography with isocratic elution using KH 2 PO 4 /K 2 HPO 4 as mobile phase with elution times of 1.67, 2.08, 6.52 and 10.72 min for As(III), DMA, MMA and As(V), respectively. Parameters affecting the hydride generation of all arsenic species were studied and the best conditions were established as a reaction coil of 150 cm, for a sample injected volume of 100 μl, a 4.0% (m/v) solution of sodium tetrahydroborate and 2.0 mol l -1 hydrochloric acid with flow rates of 2.7 and 1.7 ml min -1 , respectively and a flow rate of 500 ml min -1 for the argon carrier gas. Under the best experimental conditions, the detection limit was found to be 0.12, 0.20, 0.27 and 0.39 μg l -1 for As(III), DMA, MMA and As(V), respectively. The relative standard deviation for eight independent determinations varied from 3.9 till 8.9% for species considered at a concentration level of 10.0 μg l -1 . Recovery and comparative studies evidenced that the method is suitable for the accurate determination of arsenic species in water and beer samples

  2. High performance liquid chromatography--atomic fluorescence spectrometric determination of arsenic species in beer samples

    Energy Technology Data Exchange (ETDEWEB)

    Melo Coelho, N.M.; Parrilla, Carmen; Cervera, M.L.; Pastor, A.; Guardia, M. de la

    2003-04-10

    A method has been developed for the direct determination of As(III), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and As(V) in beers by hydride generation--atomic fluorescence spectrometry after separation of arsenic species by high performance liquid chromatography. Compounds were separated by anion-exchange chromatography with isocratic elution using KH{sub 2}PO{sub 4}/K{sub 2}HPO{sub 4} as mobile phase with elution times of 1.67, 2.08, 6.52 and 10.72 min for As(III), DMA, MMA and As(V), respectively. Parameters affecting the hydride generation of all arsenic species were studied and the best conditions were established as a reaction coil of 150 cm, for a sample injected volume of 100 {mu}l, a 4.0% (m/v) solution of sodium tetrahydroborate and 2.0 mol l{sup -1} hydrochloric acid with flow rates of 2.7 and 1.7 ml min{sup -1}, respectively and a flow rate of 500 ml min{sup -1} for the argon carrier gas. Under the best experimental conditions, the detection limit was found to be 0.12, 0.20, 0.27 and 0.39 {mu}g l{sup -1} for As(III), DMA, MMA and As(V), respectively. The relative standard deviation for eight independent determinations varied from 3.9 till 8.9% for species considered at a concentration level of 10.0 {mu}g l{sup -1}. Recovery and comparative studies evidenced that the method is suitable for the accurate determination of arsenic species in water and beer samples.

  3. Damage Atlas for Photographic materials

    Directory of Open Access Journals (Sweden)

    Kristel Van Camp

    2010-11-01

    Full Text Available La conservation des documents photographiques peut nécessiter des interventions préventives ou curatives. Ce choix est guidé par leur état de conservation. Une meilleure connaissance des détériorations est donc cruciale. Le répertoire présenté ici essaie de les classifier selon des caractéristiques spécifiques et leur niveau de gravité. Les différents types de dégradation sont illustrés et décrits avec une terminologie précise. L’auteur propose en regard de ceux-ci l’intervention qui semble la plus appropriée. Ce répertoire s’adresse à toutes les personnes concernées par la photographie, qu’ils soient dans le milieu de la conservation ou dans le domaine artistique, dans les musées ou dans les archives. In order to rescue a damaged photographic object, preventive or conservative actions are needed. Knowing the specific characteristics of different types of damage is crucial. A damage atlas can provide these characteristics. With this atlas the damage can be recognised and appropriate actions can be taken. This damage atlas offers a first attempt to such a characterisation in the field of photography. The damage atlas contains images and the necessary information about damage on photographic material. The atlas with special annotations about the terminology and the grade of the damage is meant for everybody who works with photographic material, as well in museums as in archives.

  4. Out-of-sample Forecasting Performance of Won/Dollar Exchange Rate Return Volatility Model

    Directory of Open Access Journals (Sweden)

    Hojin Lee

    2009-06-01

    Full Text Available We compare the out-of-sample forecasting performance of volatility models using daily exchange rate for the KRW/USD during the period from 1992 to 2008. For various forecasting horizons, historical volatility models with a long memory tend to make more accurate forecasts. Especially, we carefully observe the difference between the EWMA and the GARCH(1,1 model. Our empirical finding that the GARCH model puts too much weight on recent observations relative to those in the past is consistent with prior evidence showing that asset market volatility has a long memory, such as Ding and Granger (1996. The forecasting model with the lowest MSFE and VaR forecast error among the models we consider is the EWMA model in which the forecast volatility for the coming period is a weighted average of recent squared return with exponentially declining weights. In terms of forecast accuracy, it clearly dominates the widely accepted GARCH and rolling window GARCH models. We also present a multiple comparison of the out-of-sample forecasting performance of volatility using the stationary bootstrap of Politis and Romano (1994. We find that the White's reality check for the GARCH(1,1 expanding window model and the FIGARCH(1,1 expanding window model clearly reject the null hypothesis and there exists a better model than the two benchmark models. On the other hand, when the EWMA model is the benchmark, the White's for all forecasting horizons are very high, which indicates the null hypothesis may not be rejected. The Hansen's report the same results. The GARCH(1,1 expanding window model and the FIGARCH(1,1 expanding window model are dominated by the best competing model in most of the forecasting horizons. In contrast, the RiskMetrics model seems to be the most preferred. We also consider combining the forecasts generated by averaging the six raw forecasts and a trimmed set of forecasts which calculate the mean of the four forecasts after disregarding the highest and

  5. X-ray photographic apparatus

    International Nuclear Information System (INIS)

    1977-01-01

    The X-ray photographic system is designed for medical applications. Two detectors are used for surveys in different planes, and produce electrical signals which are supplied to a comparator. The electron beams are examined according to a system of reference time steps. The apparatus includes a light source and a photo-detector and enables a reference signal to be produced against which the detected signals are compared. The beam source is formed from an electron gun, an extractor electrode and an anode; beam then passes through a collimator. (G.C.)

  6. Specification for personal photographic dosemeters

    International Nuclear Information System (INIS)

    1981-01-01

    The 1981 British/International Standard Specification, prepared under the direction of the Nuclear Engineering Standards Committee and TC85 of the International Organization for Standardization, is described for personal photographic dosemeters. The Standard specifies classification, characteristics and test procedures to determine absorbed doses due to X or gamma radiations (energy less than 3 MeV) and absorbed doses due to beta radiation (max. energy 0.6 to 3 MeV), whether or not accompanied by X, gamma or bremsstrahlung photon radiation. The Standard is particularly applicable to dosemeters intended to be carried on the chest or wrist. (U.K.)

  7. National intercomparison programme for radionuclide analysis in environmental samples: Aramar radioecological laboratory performance

    Energy Technology Data Exchange (ETDEWEB)

    Arine, Bruno Burini Robles, E-mail: bruno.arine@ctmsp.mar.mil.b [Centro Tecnologico da Marinha em Sao Paulo (CTMSP/ARAMAR), Ipero, SP (Brazil). Lab. Radioecologico; Moraes, Marco Antonio P.V., E-mail: marco.proenca@ctmsp.mar.mil.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The radioecological laboratory is concerned with the measurements of background radiation (mainly uranium and thorium natural series) and present effluents in the Aramar Experimental Centre, as well as in its surroundings. The laboratory is directly subordinated to the Navy Technological Centre in Sao Paulo (CTMSP - Sao Paulo - Brazil), a military research organization whose goal is to develop nuclear and energy systems for the Brazilian naval ship propulsion. The measurements were performed in addition to the Environmental Monitoring Programme carried out in the same region. For this endeavour, the laboratory has attended to the National Intercomparison Programme conducted by the Institute for Radioprotection and Dosimetry (IRD) by analyzing several kinds of solid and liquid samples containing specific radionuclides through gamma spectrometry, liquid scintillation, alpha-beta total counting and fluorimetry techniques, since December 1995. In the last 15 years, our results were compared to another 19 laboratories and rated as 'very good' and 'acceptable' in at least 90% of the results. (author)

  8. Potential use of produced oil sample analysis to monitor SAGD performance

    Energy Technology Data Exchange (ETDEWEB)

    Li, Z. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[Nexen Petroleum International, Calgary, AB (Canada); Wollen, C. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[OPTI-Nexen Inc., Calgary, AB (Canada); Yang, P.; Fustic, M. [Nexen Petroleum International, Calgary, AB (Canada)

    2008-10-15

    Oil viscosity and compositional gradients can affect the performance of steam injection recovery processes. In this study, reservoir simulations were conducted to investigate the effects of viscosity variation with depth on steam assisted gravity drainage (SAGD) processes and produced oil characteristics. The 2-D reservoir model consisted of a reservoir with a 40 m clean sand matrix, overtopped with interbedded shales and sand. The oil phase was comprised of 2 pseudo-components representing top and bottom bitumens. Viscosities and concentrations of the pseudo-components were calculated using linear mixing rules. Four different viscosity distribution scenarios were examined. Conceptual 3-D models were then constructed to examine the characteristics of produced oil samples in scenarios with shale barriers extending down the well directions and blocking parts of the reservoir. Results from the simulations showed that produced oil characteristics are related to the in situ profiles of reservoir flow barriers. Produced oil characteristics can be used in conjunction with oil rates, surface heave and other data to predict steam chamber development and detect the presence of baffles and barriers. The relationship between the SAGD steam chamber and variations in produced fluid characteristics were accurately characterized by the simulations. It was concluded that the approach can be used to monitor SAGD steam chamber growth. 10 refs., 1 tab., 19 figs.

  9. Sex equity in French newspaper photographs: A content analysis of 2012 Olympic Games by L'Equipe.

    Science.gov (United States)

    Delorme, Nicolas; Testard, Nadège

    2015-01-01

    The aim of this article was to examine sex equity in the photographic coverage of the London 2012 Olympic Games by a French sports daily newspaper. A sample of 1073 photographs was collected and analysed. A content analysis was carried out focusing on the number of photographs, the space they cover, their location and position, the type and colour of shot and the sport they depict. A significant under-representation of female athletes' photographs was found. However, contrary to most of previous research in this field, the other quantitative and qualitative variables do not show any differences. Furthermore, a significant positive correlation between the number of photographs for each sport and the number of French medals was found (for women, for men and for the whole sample), suggesting that the photographic coverage of this event is mainly based on the success of French athletes independently of their sex.

  10. Track photographing in 8-m streamer chamber

    International Nuclear Information System (INIS)

    Anisimova, N.Z.; Davidenko, V.A.; Kantserov, V.A.; Rybakov, V.G.; Somov, S.V.

    1981-01-01

    A system for obtaining data from a streamer chamber intended for measuring muon polarization is described. An optical scheme for photographing of tracks in the chamber is given. The photographing process is complicated at the expense of large dimensions and module structure of the chamber as well as due to insufficient for direct photographing brightness of streamers. The system described was tested during a long time in a physical experiment. More than 100 thousand photos have been taken by its means [ru

  11. Agreement in the diagnosis of dental fluorosis in central incisors performed by a standardized photographic method and clinical examination Concordância no diagnóstico da fluorose dentária em incisivos centrais realizado por um método fotográfico padronizado e pelo exame clínico

    Directory of Open Access Journals (Sweden)

    Carolina Castro Martins

    2009-05-01

    Full Text Available The aim of this study was to assess agreement in the diagnosis of dental fluorosis performed by a standardized digital photographic method and a clinical examination (gold standard. 49 children (aged 7-9 years were clinically evaluated by a trained examiner for the assessment of dental fluorosis. Central incisors were evaluated for the presence or absence of dental fluorosis and were photographed with a digital camera. Photographs were presented to three pediatric dentists, who examined the images. Data were analyzed using Cohen's kappa and validity values. Agreement in the diagnosis performed by the photographic method and clinical examination was good (0.67 and accuracy was 83.7%. The prevalence of dental fluorosis was reported to be higher in the clinical examination (49% compared with the photographic method (36.7%. The photographic method presented higher specificity (96% than sensitivity (70.8%, a positive predictive value (PPV of 94.4% and a negative predictive value (NPV of 77.4%. The diagnosis of dental fluorosis performed using the photographic method presented high specificity and PPV, which indicates that the method is reproducible and reliable for recording dental fluorosis.O objetivo do estudo foi comparar o diagnóstico de fluorose dentária realizado por um método fotográfico com o exame clínico (padrão ouro. Quarenta e nove crianças, de 7 e 9 anos, foram clinicamente examinadas por um examinador calibrado para fluorose dentária. Os incisivos foram fotografados com câmera digital e as fotografias foram apresentadas a três odontopediatras, que examinaram as imagens. A concordância por kappa entre o método fotográfico e o padrão ouro foi boa (0,67 e a acurácia foi de 83,67%. A prevalência de fluorose dentária foi levemente maior pelo método clínico (49% do que pelo fotográfico (36,7%. O método fotográfico apresentou maior especificidade (96% que sensibilidade (70,83%, valor de predição positivo (VPP de 94

  12. Short Communication: A Simple Method for Performing Worm-Egg Counts on Sodium Acetate Formaldehyde-Preserved Samples

    Directory of Open Access Journals (Sweden)

    Wayne Melrose

    2012-01-01

    Full Text Available The Kato Katz method is the most common way of performing worm-egg counts on human faecal samples, but it must be done in the field using freshly collected samples. This makes it difficult to use in remote, poorly accessible situations. This paper describes a simple method for egg counts on preserved samples collected in the field and sent to a central location for further processing.

  13. Effects of Sample Size and Dimensionality on the Performance of Four Algorithms for Inference of Association Networks in Metabonomics

    NARCIS (Netherlands)

    Suarez Diez, M.; Saccenti, E.

    2015-01-01

    We investigated the effect of sample size and dimensionality on the performance of four algorithms (ARACNE, CLR, CORR, and PCLRC) when they are used for the inference of metabolite association networks. We report that as many as 100-400 samples may be necessary to obtain stable network estimations,

  14. Photographic quality assurance in diagnostic radiology, nuclear medicine, and radiation therapy. Volume II. Photographic processing, quality assurance, and the evaluation of photographic materials. Final report

    International Nuclear Information System (INIS)

    Gray, J.E.; Vucich, J.J.

    1977-03-01

    Contents: Sensitometers, densitometers, and testing equipment; Pitfalls of the photographic (and radiographic) process; Evaluation and optimization of photographic processes; Quality assurance; Odds 'n' ends

  15. Photographs of quantized vortex lines in rotating superfluid helium

    International Nuclear Information System (INIS)

    Williams, G.A.

    1974-01-01

    The spatial positions of quantized vortex lines in rotating He II have been determined using a photographic technique. Electrons are trapped on the vortices and then extracted through the liquid surface and accelerated into a phosphor screen. The light from the phosphor is transmitted to room temperature with coherent fiber optics and photographed with an image intensifier camera. Photographs taken with pure 4 He at T = 0.3 K were complete blurs. These blurs are attributed to nonequilibrium motion of the vortices, arising from the lack of normal fluid damping at this temperature. To resolve the individual vortex lines it was found necessary to add 3 He to the 4 He sample to damp the vortex motion. Photographs are presented for 3 He concentrations up to 1.6 percent. The number of vortices visible varies linearly with rotation speed, but is only about one-half the number expected from theory. The vortex lines in the apparatus were not observed to form a stable array

  16. Classical boson sampling algorithms with superior performance to near-term experiments

    Science.gov (United States)

    Neville, Alex; Sparrow, Chris; Clifford, Raphaël; Johnston, Eric; Birchall, Patrick M.; Montanaro, Ashley; Laing, Anthony

    2017-12-01

    It is predicted that quantum computers will dramatically outperform their conventional counterparts. However, large-scale universal quantum computers are yet to be built. Boson sampling is a rudimentary quantum algorithm tailored to the platform of linear optics, which has sparked interest as a rapid way to demonstrate such quantum supremacy. Photon statistics are governed by intractable matrix functions, which suggests that sampling from the distribution obtained by injecting photons into a linear optical network could be solved more quickly by a photonic experiment than by a classical computer. The apparently low resource requirements for large boson sampling experiments have raised expectations of a near-term demonstration of quantum supremacy by boson sampling. Here we present classical boson sampling algorithms and theoretical analyses of prospects for scaling boson sampling experiments, showing that near-term quantum supremacy via boson sampling is unlikely. Our classical algorithm, based on Metropolised independence sampling, allowed the boson sampling problem to be solved for 30 photons with standard computing hardware. Compared to current experiments, a demonstration of quantum supremacy over a successful implementation of these classical methods on a supercomputer would require the number of photons and experimental components to increase by orders of magnitude, while tackling exponentially scaling photon loss.

  17. "Photographers Are the Devil": An Essay in the Historiography of Photographing Schools

    Science.gov (United States)

    Hardcastle, John

    2013-01-01

    Today, the use of photographs in publications and exhibitions is commonplace, but this was not always so. This article shows how photographs of certain schools that have had lasting impact on design stand in ambiguous relationships to the buildings themselves. Photographs function as part of the design process; they record details of construction…

  18. An international study of the performance of sample collection from patients

    NARCIS (Netherlands)

    Dzik, WH; Murphy, MF; Andreu, G; Heddle, N; Hogman, C; Kekomaki, R; Murphy, S; Shimizu, M; Smit Sibinga, C.T.

    2003-01-01

    Background and Objectives Collection of a blood sample from the correct patient is the first step in the process of safe transfusion. The aim of this international collaborative study was to assess the frequency of mislabelled and miscollected samples drawn for blood grouping. Materials and Methods

  19. 8 CFR 333.2 - Attachment of photographs to documents.

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Attachment of photographs to documents. 333... PHOTOGRAPHS § 333.2 Attachment of photographs to documents. A signed photograph of the applicant must be... portion of the photograph in such a manner as not to obscure the features of the applicant. [56 FR 50495...

  20. Looking for an old aerial photograph

    Science.gov (United States)

    ,

    1997-01-01

    Attempts to photograph the surface of the Earth date from the 1800's, when photographers attached cameras to balloons, kites, and even pigeons. Today, aerial photographs and satellite images are commonplace. The rate of acquiring aerial photographs and satellite images has increased rapidly in recent years. Views of the Earth obtained from aircraft or satellites have become valuable tools to Government resource planners and managers, land-use experts, environmentalists, engineers, scientists, and a wide variety of other users. Many people want historical aerial photographs for business or personal reasons. They may want to locate the boundaries of an old farm or a piece of family property. Or they may want a photograph as a record of changes in their neighborhood, or as a gift. The U.S. Geological Survey (USGS) maintains the Earth Science Information Centers (ESIC?s) to sell aerial photographs, remotely sensed images from satellites, a wide array of digital geographic and cartographic data, as well as the Bureau?s wellknown maps. Declassified photographs from early spy satellites were recently added to the ESIC offerings of historical images. Using the Aerial Photography Summary Record System database, ESIC researchers can help customers find imagery in the collections of other Federal agencies and, in some cases, those of private companies that specialize in esoteric products.

  1. Stephen Marc: Photographer for Our Time

    Science.gov (United States)

    Smith, Toni M. Shorter

    2012-01-01

    It is said that "a picture is worth a thousand words" as visual images can express complex and multilayered ideas. Sometimes photographic imagery is so strong and resonant of certain success, struggles, or events that it becomes key to a community or generation. As historic records, photographs are uniquely able to present not only success and…

  2. 36 CFR 702.4 - Photographs.

    Science.gov (United States)

    2010-07-01

    ... 702.4 Parks, Forests, and Public Property LIBRARY OF CONGRESS CONDUCT ON LIBRARY PREMISES § 702.4 Photographs. (a) The policy set out herein applies to all individuals who are photographing Library of... conditions may include provision for a fee for services rendered consistent with the Library's policies and...

  3. PREFACE: Workshop Photograph and Program

    Science.gov (United States)

    2011-07-01

    Workshop photograph Workshop Program Sunday 28 March 201019:00-21:00 Reception at Okura Frontier Hotel Tsukuba(Buffet style dinner with drink) Monday 29 March 2010Introduction (Chair: André Rubbia (ETH Zurich))09:00 Welcome address (05') Atsuto Suzuki (KEK)09:05 Message from CERN on neutrino physics (10') Sergio Bertolucci (CERN)09:15 Message from FNAL on neutrino physics (10') Young Kee Kim (FNAL)09:25 Message from KEK on neutrino physics (10') Koichiro Nishikawa (KEK)09:35 Introductory remark on GLA2010 (10') Takuya Hasegawa (KEK) Special session (Chair: Koichiro Nishikawa (KEK))09:45 The ICARUS Liquid Argon TPC (45') Carlo Rubbia (CERN)10:30-11:00 Coffee break Main goals of Giant Liquid Argon Charge Imaging Experiments I (Chair: Takashi Kobayashi (KEK))11:00 Results from massive underground detectors (non accelerator) (30') Takaaki Kajita (ICRR, U. of Tokyo)11:30 Present long baseline neutrino experiments (30') Chang Kee Jung (SUNY Stony Brook)12:00-12:10 Workshop picture12:10-14:00 Lunch break Main goals of Giant Liquid Argon Charge Imaging Experiments II (Chair: Takashi Kobayashi (KEK))14:00 Physics goals of the next generation massive underground experiments (30') David Wark (Imperial College London)14:30 Near detectors for long baseline neutrino experiments (20') Tsuyoshi Nakaya (Kyoto U.) Lessons on Liquid Argon Charge Imaging technology from ongoing developments (Chair: Chang Kee Jung (SUNY Stony Brook))14:50 WARP (30') Claudio Montanari (U. of Pavia)15:20 ArDM (30') Alberto Marchionni (ETH Zurich)15:50 From ArgoNeuT to MicroBooNE (30') Bonnie Fleming (Yale U.)16:20 250L (30') Takasumi Maruyama (KEK)16:50 The DEAP/CLEAN project (20') Mark Boulay (Queen's U.)17:10-17:40 Coffee break Lessons from Xe based Liquids Imaging detectors (Chair: Flavio Cavanna (U. of L'Aquilla))17:30 MEG (20') Satoshi Mihara (KEK)17:50 The XENON project (20') Elena Aprile (Columbia U.)18:10 XMASS (20') Hiroyuki Sekiya (ICRR, U. of Tokyo) Studies on physics performance (Chair

  4. Exploratory factor analysis of Kenny Music Performance Anxiety Inventory (K-MPAI) in a Brazilian musician sample

    OpenAIRE

    Ana Elisa Medeiros Barbar; José Alexandre de Souza; Flávia de Lima Osório

    2015-01-01

    Abstract Background The Kenny Music Performance Anxiety Inventory (K-MPAI) is very significant among the available instruments which measures Musical Performance Anxiety (MPA). Objective The aim of this study is to find evidence of validity of the Kenny Music Performance Anxiety Inventory (K-MPAI), in its translated and adapted Brazilian version, through the study of its factor structure. Methods A convenience sample of 230 amateur musicians completed the K-MPAI. Results The initial facto...

  5. Examining gray matter structure associated with academic performance in a large sample of Chinese high school students

    OpenAIRE

    Song Wang; Ming Zhou; Taolin Chen; Xun Yang; Guangxiang Chen; Meiyun Wang; Qiyong Gong

    2017-01-01

    Achievement in school is crucial for students to be able to pursue successful careers and lead happy lives in the future. Although many psychological attributes have been found to be associated with academic performance, the neural substrates of academic performance remain largely unknown. Here, we investigated the relationship between brain structure and academic performance in a large sample of high school students via structural magnetic resonance imaging (S-MRI) using voxel-based morphome...

  6. Study of performance characteristics of a radiochemical method to determine uranium in biological samples

    International Nuclear Information System (INIS)

    Puga, Maria J.; Cerchietti, Maria L.R.; Prudenzo, J.E.; Arguelles, Maria G.

    2005-01-01

    In this paper is described a methodology to calculate detection limit (Ld), quantification level (Lq) and minimum detectable activity (MDA) in a radiochemical method for determination of uranium in urine samples. The concentration is measured by fluorimetry and alpha gross activity using liquid scintillation counting (LSC). The calculation of total propagated uncertainty on a spike sample is presented. Furthermore, the major sources of uncertainty and percentage contribution in both measurements are assessed. (author)

  7. The effect of sample storage on the performance and reproducibility of the galactomannan EIA test.

    Science.gov (United States)

    Kimpton, George; White, P Lewis; Barnes, Rosemary A

    2014-08-01

    Galactomannan enzyme immune assay (GM EIA) is a nonculture test for detecting invasive aspergillosis (IA) forming a key part of diagnosis and management. Recent reports have questioned the reproducibility of indices after sample storage. To investigate this, 198 serum samples (72 from cases and 126 from controls) and 61 plasma samples (24 from cases and 37 from controls), initially tested between 2010 and 2013, were retested to determine any change in index. Data were also collected on circulatory protein levels for false-positive serum samples. Serum indices significantly declined on retesting (median: initial, 0.50, retest, 0.23; P < 0.0001). This was shown to be diagnosis dependent as the decline was apparent on retesting of control samples (median: initial 0.50, retest 0.12; P < 0.0001), but was not evident with case samples (median: initial, 0.80, retest, 0.80; P = 0.724). Plasma samples showed little change on reanalysis after long-term storage at 4°C. Retesting after freezing showed a decrease in index values for controls (median: initial 0.40, retest 0.26; P = 0.0505), but no significant change in cases. Circulatory proteins showed a correlation between serum albumin concentration and difference in index value on retesting. Overall, this study suggests that a lack of reproducibility in GM EIA positivity is only significant when disease is absent. Retesting after freezing helps to differentiate false-positive GM EIA results and, with consecutive positivity, could help to improve accuracy in predicting disease status. The freezing of samples prior to testing could potentially reduce false-positivity rates and the need to retest. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Evaluation of species richness estimators based on quantitative performance measures and sensitivity to patchiness and sample grain size

    Science.gov (United States)

    Willie, Jacob; Petre, Charles-Albert; Tagg, Nikki; Lens, Luc

    2012-11-01

    Data from forest herbaceous plants in a site of known species richness in Cameroon were used to test the performance of rarefaction and eight species richness estimators (ACE, ICE, Chao1, Chao2, Jack1, Jack2, Bootstrap and MM). Bias, accuracy, precision and sensitivity to patchiness and sample grain size were the evaluation criteria. An evaluation of the effects of sampling effort and patchiness on diversity estimation is also provided. Stems were identified and counted in linear series of 1-m2 contiguous square plots distributed in six habitat types. Initially, 500 plots were sampled in each habitat type. The sampling process was monitored using rarefaction and a set of richness estimator curves. Curves from the first dataset suggested adequate sampling in riparian forest only. Additional plots ranging from 523 to 2143 were subsequently added in the undersampled habitats until most of the curves stabilized. Jack1 and ICE, the non-parametric richness estimators, performed better, being more accurate and less sensitive to patchiness and sample grain size, and significantly reducing biases that could not be detected by rarefaction and other estimators. This study confirms the usefulness of non-parametric incidence-based estimators, and recommends Jack1 or ICE alongside rarefaction while describing taxon richness and comparing results across areas sampled using similar or different grain sizes. As patchiness varied across habitat types, accurate estimations of diversity did not require the same number of plots. The number of samples needed to fully capture diversity is not necessarily the same across habitats, and can only be known when taxon sampling curves have indicated adequate sampling. Differences in observed species richness between habitats were generally due to differences in patchiness, except between two habitats where they resulted from differences in abundance. We suggest that communities should first be sampled thoroughly using appropriate taxon sampling

  9. The first DC performance test and analysis of CC conductor short sample at ASIPP conductor test facility

    International Nuclear Information System (INIS)

    Shi Yi; Wu Yu; Liu Huajun; Long Feng; Qian Li; Ren Zhibin; Li Shaolei; Liu Bo; Chen Jinglin

    2012-01-01

    Highlights: ► In this study the first DC performance experiments of ITER correction coil conductor short sample have been carried out in ASIPP test facility. ► A CC conductor short sample was fabricated and tested to confirm the capability of this test facility for qualification tests of CC conductors. ► There is no obvious impact of cycling on DC performance measurement. ► Those measured results of current sharing temperature are in agreement with the expected results from strand scaling - Abstract: The first DC performance experiments of ITER correction coil (CC) conductor short sample have been carried out in the conductor test facility of Institute of Plasma Physics, CAS (ASIPP) in January this year. Those experiments aim to investigate the DC performance of ITER CC conductor. The tested conductor short sample is bended as a half circle with the diameter of 270 mm to meet the background magnetic field shape. The half circle part of sample is longer than the final twist pitch. The current sharing temperature (T cs ) in the 3.86 T external magnetic field (B ex ), ≤12 kA could be measured including the critical current (I c ) run. There is no obvious impact of 1000 cycles on DC performance. Those measured T cs results are in agreement with the expected results from strand scaling.

  10. Aging Audiences: Association of Live Performance Attendance and Cognitive Decline in a Biracial Sample.

    Science.gov (United States)

    Rajan, Kumar B; Rajan, Rekha S; Manning, Lydia K; Evans, Denis A

    2018-03-01

    To examine if attendance in live performances was associated with change in cognition among African Americans (AAs) and European Americans (EAs). The study consisted of 5,567 older adults with at least follow-up interview and analyzed using a linear mixed effects regression model adjusting for demographic and health variables. We found that frequent performance attendance was associated with slower decline in composite cognitive function among older AAs and EAs. Attending 10 or more performances per year was associated with 23% slower cognitive decline among AAs and 31% slower cognitive decline among EAs compared with those who never attend any performance. However, this difference was not significant ( p = .56). Attending live performances was also associated with slower decline in individual tests of perceptual speed, episodic memory, and mini-mental state exam (MMSE). Our findings suggest that live performances form a valuable component of arts engagement and should be encouraged for potential cognitive benefits.

  11. Mobile dynamic passive sampling of trace organic compounds: Evaluation of sampler performance in the Danube River.

    Science.gov (United States)

    Vrana, Branislav; Smedes, Foppe; Allan, Ian; Rusina, Tatsiana; Okonski, Krzysztof; Hilscherová, Klára; Novák, Jiří; Tarábek, Peter; Slobodník, Jaroslav

    2018-03-29

    A "dynamic" passive sampling (DPS) device, consisting of an electrically driven large volume water pumping device coupled to a passive sampler exposure cell, was designed to enhance the sampling rate of trace organic compounds. The purpose of enhancing the sampling rate was to achieve sufficient method sensitivity, when the period available for sampling is limited to a few days. Because the uptake principle in the DPS remains the same as for conventionally-deployed passive samplers, free dissolved concentrations can be derived from the compound uptake using available passive sampler calibration parameters. This was confirmed by good agreement between aqueous concentrations of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and hexachlorobenzene (HCB) derived from DPS and conventional caged passive sampler. The DPS device enhanced sampling rates of compounds that are accumulated in samplers under water boundary layer control (WBL) more than five times compared with the conventionally deployed samplers. The DPS device was deployed from a ship cruising downstream the Danube River to provide temporally and spatially integrated concentrations. A DPS-deployed sampler with surface area of 400cm 2 can reach sampling rates up to 83Ld -1 . The comparison of three passive samplers made of different sorbents and co-deployed in the DPS device, namely silicone rubber (SR), low density polyethylene (LDPE) and SDB-RPS Empore™ disks showed a good correlation of surface specific uptake for compounds that were sampled integratively during the entire exposure period. This provided a good basis for a cross-calibration between the samplers. The good correlation of free dissolved PAHs, PCBs and HCB concentration estimates obtained using SR and LDPE confirmed that both samplers are suitable for the identification of concentration gradients and trends in the water column. We showed that the differences in calculated aqueous concentrations between sampler types

  12. Rigorous Training of Dogs Leads to High Accuracy in Human Scent Matching-To-Sample Performance.

    Directory of Open Access Journals (Sweden)

    Sophie Marchal

    Full Text Available Human scent identification is based on a matching-to-sample task in which trained dogs are required to compare a scent sample collected from an object found at a crime scene to that of a suspect. Based on dogs' greater olfactory ability to detect and process odours, this method has been used in forensic investigations to identify the odour of a suspect at a crime scene. The excellent reliability and reproducibility of the method largely depend on rigor in dog training. The present study describes the various steps of training that lead to high sensitivity scores, with dogs matching samples with 90% efficiency when the complexity of the scents presented during the task in the sample is similar to that presented in the in lineups, and specificity reaching a ceiling, with no false alarms in human scent matching-to-sample tasks. This high level of accuracy ensures reliable results in judicial human scent identification tests. Also, our data should convince law enforcement authorities to use these results as official forensic evidence when dogs are trained appropriately.

  13. X-radiography using photographic papers

    International Nuclear Information System (INIS)

    Nitiyaporn, W.

    1986-01-01

    The objective of this research is to study the possibility of using photographic paper, available on the market, for x-ray radiography instead of x-ray film which is more expensive and more complicate to develop. This research concerned about (1) the method and the limitation of x-ray radiography by using 3 types of photographic paper, namely, F2, F3 and F4 distributed by the Kodak Company, as the screen with 3 different kinds of intensifying screens produced by the Phillips Company, Toshiba Company and Picker Company to increase photographic efficiency; (2) correction factor between these 3 types of photographic paper and intensifying screens; (3) the most suitable combination of photographic paper and intensifying screens used; (4) the result of using photographic paper and x-ray film in x-ray radiography regarding quality, cost and film developing. From the research, it was found that (1) the combination of intensifying screen from Picker Company and Kodak photographic paper No. F4 coating with silver bromide with a little mixture of silver iodide resulted in higher sensitivity and more contrast than other combination; (2) photographic papers had more limitation than x-ray film in the sense that it could be used with the iron test piece no thicker than 3 cm.with the x-ray energy of 220 k Vp; (3) photographic papers would give almost the same degree of contrast and sensitivity as x-ray film when used with thin test specimens. For instance the smallest wire No.12 of DIN 62 FE could be seen in the photographic paper at 220 k Vp while it could be seen in the x-ray film at 200 k Vp while it could be seen in the x-ray film at 200 k Vp. The exposure of photographic paper would be in vicinity of x-ray film when it was used with thin test specimens. Photographic paper would produce sharpness definition, density and contrast picture and also details of the picture closely to what given by x-ray film. It is concluded that if the test specimens are thin, photographic papers

  14. Application of calorimetry to the assessment of the performance of ITER Nb3Sn TF conductor samples in SULTAN tests

    International Nuclear Information System (INIS)

    Richard, L Savoldi; Zanino, R

    2008-01-01

    In the frame of the International Thermonuclear Experimental Reactor (ITER), several short full-size Nb 3 Sn samples of candidate toroidal field (TF) conductors were tested in 2007 at the SULTAN facility, PSI Villigen, Switzerland, in conditions relevant to the ITER TF (background magnetic field of 10.78 T and transport current of 68 kA). The performance of a SULTAN sample is determined by the current sharing temperature T CS . This can be obtained in principle from voltage measurements along the conductor sample, but the procedure is not free of issues and ambiguities. Here a complementary approach, based on the calorimetric assessment of the Joule heating due to current sharing, is critically discussed. Suitable algorithms are defined and the respective error bars are estimated, also based on numerical thermal-hydraulic modeling. The calorimetric approach is then applied to assess the performance of the samples tested in 2007 and compared with the results of the standard (electrical) approach

  15. Production of aerosols by optical catapulting: Imaging, performance parameters and laser-induced plasma sampling rate

    International Nuclear Information System (INIS)

    Abdelhamid, M.; Fortes, F.J.; Fernández-Bravo, A.; Harith, M.A.; Laserna, J.J.

    2013-01-01

    Optical catapulting (OC) is a sampling and manipulation method that has been extensively studied in applications ranging from single cells in heterogeneous tissue samples to analysis of explosive residues in human fingerprints. Specifically, analysis of the catapulted material by means of laser-induced breakdown spectroscopy (LIBS) offers a promising approach for the inspection of solid particulate matter. In this work, we focus our attention in the experimental parameters to be optimized for a proper aerosol generation while increasing the particle density in the focal region sampled by LIBS. For this purpose we use shadowgraphy visualization as a diagnostic tool. Shadowgraphic images were acquired for studying the evolution and dynamics of solid aerosols produced by OC. Aluminum silicate particles (0.2–8 μm) were ejected from the substrate using a Q-switched Nd:YAG laser at 1064 nm, while time-resolved images recorded the propagation of the generated aerosol. For LIBS analysis and shadowgraphy visualization, a Q-switched Nd:YAG laser at 1064 nm and 532 nm was employed, respectively. Several parameters such as the time delay between pulses and the effect of laser fluence on the aerosol production have been also investigated. After optimization, the particle density in the sampling focal volume increases while improving the aerosol sampling rate till ca. 90%. - Highlights: • Aerosol generation by optical catapulting has been successfully optimized. • We study the evolution and dynamics of solid aerosols produced by OC. • We use shadowgraphy visualization as a diagnostic tool. • Effects of temporal conditions and laser fluence on the elevation of the aerosol cloud have been investigated. • The observed LIBS sampling rate increased from 50% reported before to approximately 90%

  16. Devils Hole, Nevada—A photographic story of a restricted subaqueous environment

    Science.gov (United States)

    Hoffman, Ray J.

    2017-07-24

    This report presents selected photographic images taken by the author during U.S. Geological Survey (USGS) research into paleoclimatology and geochemistry in Devils Hole cavern during 1984 to 1993 in cooperation with the National Park Service. The unaltered suite of photographs was prepared by the USGS dive team as an aid to assist nondiving scientists with a visual perspective of the environment where earth-science samples were collected and subsequently analyzed for chemical and isotopic composition.

  17. Networked control systems with communication constraints :tradeoffs between sampling intervals, delays and performance

    NARCIS (Netherlands)

    Heemels, W.P.M.H.; Teel, A.R.; Wouw, van de N.; Nesic, D.

    2010-01-01

    There are many communication imperfections in networked control systems (NCS) such as varying transmission delays, varying sampling/transmission intervals, packet loss, communication constraints and quantization effects. Most of the available literature on NCS focuses on only some of these aspects,

  18. The finite sample performance of estimators for mediation analysis under sequential conditional independence

    DEFF Research Database (Denmark)

    Huber, Martin; Lechner, Michael; Mellace, Giovanni

    Using a comprehensive simulation study based on empirical data, this paper investigates the finite sample properties of different classes of parametric and semi-parametric estimators of (natural) direct and indirect causal effects used in mediation analysis under sequential conditional independence...

  19. Performances on five verbal fluency tests in a healthy, elderly Danish sample

    DEFF Research Database (Denmark)

    Stokholm, Jette; Jørgensen, Kasper; Vogel, Asmus

    2013-01-01

    Verbal fluency tests are widely used as measures of language and executive functions. This study presents data for five tests; semantic fluency (animals, supermarket items and alternating between cities and professions), lexical fluency (s-words), and action fluency (verbs) based on a sample of 100...

  20. The finite sample performance of estimators for mediation analysis under sequential conditional independence

    DEFF Research Database (Denmark)

    Huber, Martin; Lechner, Michael; Mellace, Giovanni

    2016-01-01

    Using a comprehensive simulation study based on empirical data, this paper investigates the finite sample properties of different classes of parametric and semi-parametric estimators of (natural) direct and indirect causal effects used in mediation analysis under sequential conditional independen...... of the methods often (but not always) varies with the features of the data generating process....

  1. Agreement between radiographic and photographic trabecular patterns

    International Nuclear Information System (INIS)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der; Spruijt, R.J.; Mosekilde, L.

    1998-01-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach's α>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  2. Agreement between radiographic and photographic trabecular patterns

    Energy Technology Data Exchange (ETDEWEB)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der [Dept. of Oral Radiology, Academic Centre for Dentistry, Amsterdam (Netherlands); Spruijt, R.J. [Div. of Psychosocial Research and Epidemiology, Netherlands Cancer Inst., Amsterdam (Netherlands); Mosekilde, L. [Dept. of Cell Biology, Univ. of Aarhus (Denmark)

    1998-11-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach`s {alpha}>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  3. The Photoshop CS4 Companion for Photographers

    CERN Document Server

    Story, Derrick

    2009-01-01

    "Derrick shows that Photoshop can be friendly as well as powerful. In part, he does that by focusing photographers on the essential steps of an efficient workflow. With this guide in hand, you'll quickly learn how to leverage Photoshop CS4's features to organize and improve your pictures."-- John Nack, Principal Product Manager, Adobe Photoshop & BridgeMany photographers -- even the pros -- feel overwhelmed by all the editing options Photoshop provides. The Photoshop CS4 Companion for Photographers pares it down to only the tools you'll need most often, and shows you how to use those tools as

  4. Guidelines for the Ethical Publication of Facial Photographs and Review of the Literature.

    Science.gov (United States)

    Bennett, Katelyn G; Bonawitz, Steven C; Vercler, Christian J

    2018-01-01

    Facial photography presents a unique ethical dilemma, as faces are difficult to deidentify for publication. We performed a review of the literature to examine current guidelines for the publication of facial photographs. We also reviewed societies' websites, journal requirements, and ethical and legal aspects of confidentiality. Most articles emphasized the importance of consent for photography and publication. Masking is not appropriate, but some journals continue to allow masking. Most legislation allows patients to restrict the uses of photographs. In the end, it is imperative to protect patient privacy by obtaining consent for photograph publication after full disclosure of risks, and specific recommendations are provided regarding a comprehensive consent process.

  5. Comprehensive sample analysis using high performance liquid chromatography with multi-detection

    International Nuclear Information System (INIS)

    Pravadali, Sercan; Bassanese, Danielle N.; Conlan, Xavier A.; Francis, Paul S.; Smith, Zoe M.; Terry, Jessica M.; Shalliker, R. Andrew

    2013-01-01

    Graphical abstract: -- Highlights: •Detection selectivity was assessed with 6 detection modes. •Natural samples show great diversity in detection selectivity. •Complex samples require evaluation using a multifaceted approach to detection. •23/30 known compounds (detected by MS) detected by chemiluminescence, DPPH and UV. -- Abstract: Herein we assess the separation space offered by a liquid chromatography system with an optimised uni-dimensional separation for the determination of the key chemical entities in the highly complex matrix of a tobacco leaf extract. Multiple modes of detection, including UV–visible absorbance, chemiluminescence (acidic potassium permanganate, manganese(IV), and tris(2,2′-bipyridine)ruthenium(III)), mass spectrometry and DPPH radical scavenging were used in an attempt to systematically reduce the data complexity of the sample whilst obtaining a greater degree of molecule-specific information. A large amount of chemical data was obtained, but several limitations in the ability to assign detector responses to particular compounds, even with the aid of complementary detection systems, were observed. Thirty-three compounds were detected via MS on the tobacco extract and 12 out of 32 compounds gave a peak height ratio (PHR) greater than 0.33 on one or more detectors. This paper serves as a case study of these limitations, illustrating why multidimensional chromatography is an important consideration when developing a comprehensive chemical detection system

  6. Comprehensive sample analysis using high performance liquid chromatography with multi-detection

    Energy Technology Data Exchange (ETDEWEB)

    Pravadali, Sercan [Australian Centre for Research on Separation Sciences (ACROSS), School of Science and Health, University of Western Sydney (Parramatta), NSW 1797 (Australia); Bassanese, Danielle N.; Conlan, Xavier A.; Francis, Paul S.; Smith, Zoe M.; Terry, Jessica M. [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Victoria 3216 (Australia); Shalliker, R. Andrew, E-mail: R.Shalliker@uws.edu.au [Australian Centre for Research on Separation Sciences (ACROSS), School of Science and Health, University of Western Sydney (Parramatta), NSW 1797 (Australia)

    2013-11-25

    Graphical abstract: -- Highlights: •Detection selectivity was assessed with 6 detection modes. •Natural samples show great diversity in detection selectivity. •Complex samples require evaluation using a multifaceted approach to detection. •23/30 known compounds (detected by MS) detected by chemiluminescence, DPPH and UV. -- Abstract: Herein we assess the separation space offered by a liquid chromatography system with an optimised uni-dimensional separation for the determination of the key chemical entities in the highly complex matrix of a tobacco leaf extract. Multiple modes of detection, including UV–visible absorbance, chemiluminescence (acidic potassium permanganate, manganese(IV), and tris(2,2′-bipyridine)ruthenium(III)), mass spectrometry and DPPH radical scavenging were used in an attempt to systematically reduce the data complexity of the sample whilst obtaining a greater degree of molecule-specific information. A large amount of chemical data was obtained, but several limitations in the ability to assign detector responses to particular compounds, even with the aid of complementary detection systems, were observed. Thirty-three compounds were detected via MS on the tobacco extract and 12 out of 32 compounds gave a peak height ratio (PHR) greater than 0.33 on one or more detectors. This paper serves as a case study of these limitations, illustrating why multidimensional chromatography is an important consideration when developing a comprehensive chemical detection system.

  7. Actual distribution of Cronobacter spp. in industrial batches of powdered infant formula and consequences for performance of sampling strategies.

    Science.gov (United States)

    Jongenburger, I; Reij, M W; Boer, E P J; Gorris, L G M; Zwietering, M H

    2011-11-15

    The actual spatial distribution of microorganisms within a batch of food influences the results of sampling for microbiological testing when this distribution is non-homogeneous. In the case of pathogens being non-homogeneously distributed, it markedly influences public health risk. This study investigated the spatial distribution of Cronobacter spp. in powdered infant formula (PIF) on industrial batch-scale for both a recalled batch as well a reference batch. Additionally, local spatial occurrence of clusters of Cronobacter cells was assessed, as well as the performance of typical sampling strategies to determine the presence of the microorganisms. The concentration of Cronobacter spp. was assessed in the course of the filling time of each batch, by taking samples of 333 g using the most probable number (MPN) enrichment technique. The occurrence of clusters of Cronobacter spp. cells was investigated by plate counting. From the recalled batch, 415 MPN samples were drawn. The expected heterogeneous distribution of Cronobacter spp. could be quantified from these samples, which showed no detectable level (detection limit of -2.52 log CFU/g) in 58% of samples, whilst in the remainder concentrations were found to be between -2.52 and 2.75 log CFU/g. The estimated average concentration in the recalled batch was -2.78 log CFU/g and a standard deviation of 1.10 log CFU/g. The estimated average concentration in the reference batch was -4.41 log CFU/g, with 99% of the 93 samples being below the detection limit. In the recalled batch, clusters of cells occurred sporadically in 8 out of 2290 samples of 1g taken. The two largest clusters contained 123 (2.09 log CFU/g) and 560 (2.75 log CFU/g) cells. Various sampling strategies were evaluated for the recalled batch. Taking more and smaller samples and keeping the total sampling weight constant, considerably improved the performance of the sampling plans to detect such a type of contaminated batch. Compared to random sampling

  8. The COMT Val158 allele is associated with impaired delayed-match-to-sample performance in ADHD

    Directory of Open Access Journals (Sweden)

    Matthews Natasha

    2012-05-01

    Full Text Available Abstract Background This study explored the association between three measures of working memory ability and genetic variation in a range of catecholamine genes in a sample of children with ADHD. Methods One hundred and eighteen children with ADHD performed three working memory measures taken from the CANTAB battery (Spatial Span, Delayed-match-to-sample, and Spatial Working Memory. Associations between performance on working memory measures and allelic variation in catecholamine genes (including those for the noradrenaline transporter [NET1], the dopamine D4 and D2 receptor genes [DRD4; DRD2], the gene encoding dopamine beta hydroxylase [DBH] and catechol-O-methyl transferase [COMT] were investigated using regression models that controlled for age, IQ, gender and medication status on the day of test. Results Significant associations were found between performance on the delayed-match-to-sample task and COMT genotype. More specifically, val/val homozygotes produced significantly more errors than did children who carried a least one met allele. There were no further associations between allelic variants and performance across the other working memory tasks. Conclusions The working memory measures employed in the present study differed in the degree to which accurate task performance depended upon either the dynamic updating and/or manipulation of items in working memory, as in the spatial span and spatial working memory tasks, or upon the stable maintenance of representations, as in the delay-match–to-sample task. The results are interpreted as evidence of a relationship between tonic dopamine levels associated with the met COMT allele and the maintenance of stable working memory representations required to perform the delayed-match-to-sample-task.

  9. The effects of sampling bias and model complexity on the predictive performance of MaxEnt species distribution models.

    Science.gov (United States)

    Syfert, Mindy M; Smith, Matthew J; Coomes, David A

    2013-01-01

    Species distribution models (SDMs) trained on presence-only data are frequently used in ecological research and conservation planning. However, users of SDM software are faced with a variety of options, and it is not always obvious how selecting one option over another will affect model performance. Working with MaxEnt software and with tree fern presence data from New Zealand, we assessed whether (a) choosing to correct for geographical sampling bias and (b) using complex environmental response curves have strong effects on goodness of fit. SDMs were trained on tree fern data, obtained from an online biodiversity data portal, with two sources that differed in size and geographical sampling bias: a small, widely-distributed set of herbarium specimens and a large, spatially clustered set of ecological survey records. We attempted to correct for geographical sampling bias by incorporating sampling bias grids in the SDMs, created from all georeferenced vascular plants in the datasets, and explored model complexity issues by fitting a wide variety of environmental response curves (known as "feature types" in MaxEnt). In each case, goodness of fit was assessed by comparing predicted range maps with tree fern presences and absences using an independent national dataset to validate the SDMs. We found that correcting for geographical sampling bias led to major improvements in goodness of fit, but did not entirely resolve the problem: predictions made with clustered ecological data were inferior to those made with the herbarium dataset, even after sampling bias correction. We also found that the choice of feature type had negligible effects on predictive performance, indicating that simple feature types may be sufficient once sampling bias is accounted for. Our study emphasizes the importance of reducing geographical sampling bias, where possible, in datasets used to train SDMs, and the effectiveness and essentialness of sampling bias correction within MaxEnt.

  10. Calibration and field performance of membrane-enclosed sorptive coating for integrative passive sampling of persistent organic pollutants in water

    International Nuclear Information System (INIS)

    Vrana, Branislav; Paschke, Albrecht; Popp, Peter

    2006-01-01

    Membrane-enclosed sorptive coating (MESCO) is a miniaturised monitoring device that enables integrative passive sampling of persistent, hydrophobic organic pollutants in water. The system combines the passive sampling with solventless preconcentration of organic pollutants from water and subsequent desorption of analytes on-line into a chromatographic system. Exchange kinetics of chemicals between water and MESCO was studied at different flow rates of water, in order to characterize the effect of variable environmental conditions on the sampler performance, and to identify a method for in situ correction of the laboratory-derived calibration data. It was found that the desorption of chemicals from MESCO into water is isotropic to the absorption of the analytes onto the sampler under the same exposure conditions. This allows for the in situ calibration of the uptake of pollutants using elimination kinetics of performance reference compounds and more accurate estimates of target analyte concentrations. A field study was conducted to test the sampler performance alongside spot sampling. A good agreement of contaminant patterns and water concentrations was obtained by the two sampling techniques. - A robust calibration method of a passive sampling device for monitoring of persistent organic pollutants in water is described

  11. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab...

  12. The Applicability of 360 Degree Feedback Performance Appraisal System: A Brigade Sample

    Directory of Open Access Journals (Sweden)

    Hakan TURGUT

    2012-03-01

    Full Text Available On the subject of measuring individual performances, which considered to be one of the fundamental functions of the human resources management process, 360 Degree Feedback Performance Appraisal System (360 DFPAS preferred for taking into account more than one aspect while providing opportunities in order to achieve more objective results. It’s been thought that the applicability of the above mentioned method is not investigated enough in the public sector where most of the employments take place in Turkey. The purpose of this study is to probe into the applicability of the 360 DFPAS on low and mid-level managers in a brigade. Within this framework, differences between the raters (manager, subordinate, peer, client, self-evaluation have been examined and comparisons made between traditional performance appraisal and 360 DFPAS. There are meaningful differences only inner client between two different evaluation methods (Traditional manager evalution-360 DFPAS within evaluation raters. But there aren’t any meaningful differences between traditional performance appraisal and 360 DFPAS as whole method.

  13. Heritability of Verbal and Performance Intelligence in a Pediatric Longitudinal Sample

    NARCIS (Netherlands)

    van Soelen, I.L.C.; Brouwer, R.M.; van Leeuwen, M.; Kahn, R.S.; Hulshoff Pol, H.E.; Boomsma, D.I.

    2011-01-01

    The longitudinal stability of IQ is well-documented as is its increasing heritability with age. In a longitudinal twin study, we addressed the question to what extent heritability and stability differ for full scale (FSIQ), verbal (VIQ), and performance IQ (PIQ) in childhood (age 9-11 years), and

  14. Use of individual containers for prostate biopsy samples: Do we gain diagnostic performance?

    Science.gov (United States)

    Panach-Navarrete, J; García-Morata, F; Valls-González, L; Martínez-Jabaloyas, J M

    2016-05-01

    Prostate cores from transrectal biopsies are usually sent in separate vials for pathological processing. Although this is a common practice, there are controversial studies on its usefulness. We wanted to compare the rate of prostate cancer diagnosis between processing samples in 2 containers and processing them in individual containers to see if there are differences. Our secondary objective was to check the rate of diagnosis of various tumour subtypes in each of the 2 groups. A retrospective observational study was conducted of 2,601 cases of prostate biopsies. Ten cores were extracted in each biopsy. We divided the sample into 2 groups: biopsies sent in 2 containers to the department of pathology (left and right lobes) or sent in 10 (one for each cylinder), according to the different criteria used in our centre in the past. We then classified the cases according to the absence of neoplasia, insignificant tumour (involvement of just 1 cylinder, container group, and 824 were included in the 10-container group. We diagnosed a rate of 32.4% of cancers in the 2-container group and 40% in the 10-container group, a difference that was statistically significant (Pcontainer group than in the 10-container group (6.4% vs. 4.3%, respectively; P=.03). Samples with a Gleason score of 6 were diagnosed more often in the 10-container group than in the 2-container group (11.9% vs. 8.1%, respectively; P=.002). The same occurred with the Gleason score≥7 (23.8% in the 10-container group vs. 17.9% in the 2-container group; Pcontainers. Once the procedure was conducted, we also observed in our series a reduction in the diagnoses of insignificant carcinoma to the detriment of an increased diagnosis of not insignificant carcinomas. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2009-01-01

    Full Text Available Background/Aim. Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Methods. Separation of the drug from matrix is achieved by reversedphase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1 at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10 using chlorophorm. Results. Calibration curves were in the range 0.1-5 μg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD of carbamazepine in serum and saliva were 0.166 and 0.178 μg/mL, respectively. Limits of quantification (LOQ in the serum and saliva were 0.237 and 0.226 μg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001. Conclusion. The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  16. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav

    2009-05-01

    Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  17. Further examination of embedded performance validity indicators for the Conners' Continuous Performance Test and Brief Test of Attention in a large outpatient clinical sample.

    Science.gov (United States)

    Sharland, Michael J; Waring, Stephen C; Johnson, Brian P; Taran, Allise M; Rusin, Travis A; Pattock, Andrew M; Palcher, Jeanette A

    2018-01-01

    Assessing test performance validity is a standard clinical practice and although studies have examined the utility of cognitive/memory measures, few have examined attention measures as indicators of performance validity beyond the Reliable Digit Span. The current study further investigates the classification probability of embedded Performance Validity Tests (PVTs) within the Brief Test of Attention (BTA) and the Conners' Continuous Performance Test (CPT-II), in a large clinical sample. This was a retrospective study of 615 patients consecutively referred for comprehensive outpatient neuropsychological evaluation. Non-credible performance was defined two ways: failure on one or more PVTs and failure on two or more PVTs. Classification probability of the BTA and CPT-II into non-credible groups was assessed. Sensitivity, specificity, positive predictive value, and negative predictive value were derived to identify clinically relevant cut-off scores. When using failure on two or more PVTs as the indicator for non-credible responding compared to failure on one or more PVTs, highest classification probability, or area under the curve (AUC), was achieved by the BTA (AUC = .87 vs. .79). CPT-II Omission, Commission, and Total Errors exhibited higher classification probability as well. Overall, these findings corroborate previous findings, extending them to a large clinical sample. BTA and CPT-II are useful embedded performance validity indicators within a clinical battery but should not be used in isolation without other performance validity indicators.

  18. The integrated performance evaluation program quality assurance guidance in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-05-01

    EM's (DOE's Environmental Restoration and Waste Management) Integrated Performance Evaluation Program (IPEP) has the purpose of integrating information from existing PE programs with expanded QA activities to develop information about the quality of radiological, mixed waste, and hazardous environmental sample analyses provided by all laboratories supporting EM programs. The guidance addresses the goals of identifying specific PE sample programs and contacts, identifying specific requirements for participation in DOE's internal and external (regulatory) programs, identifying key issues relating to application and interpretation of PE materials for EM headquarters and field office managers, and providing technical guidance covering PE materials for site-specific activities. (PE) Performance Evaluation materials or samples are necessary for the quality assurance/control programs covering environmental data collection

  19. New ISO standard - personnel photographic film dosemeters

    International Nuclear Information System (INIS)

    Brabec, D.

    1980-01-01

    The ISO Standard 1757 ''Personnel Photographic Film Dosemeters'', issued in June 1980, is briefly described. UVVVR's own dosemeter developed for use in the national film dosimetry service in Czechoslovakia is evaluated in relation to this ISO Standard. (author)

  20. Reliability of the craniocervical posture assessment: visual and angular measurements using photographs and radiographs.

    Science.gov (United States)

    Gadotti, Inae C; Armijo-Olivo, Susan; Silveira, Anelise; Magee, David

    2013-01-01

    The purposes of this study were to determine the intrarater and interrater reliability of the craniocervical posture in a sagittal view using quantitative measurements on photographs and radiographs and to determine the agreement of the visual assessment of posture between raters. One photograph and 1 radiograph of the sagittal craniocervical posture were simultaneously taken from 39 healthy female subjects. Three angles were measured on the photographs and 10 angles on the radiographs of 22 subjects using Alcimage software (Alcimage; Uberlândia, MG, Brazil). Two repeated measurements were performed by 2 raters. The measurements were compared within and between raters to test the intrarater and interrater reliability, respectively. Intraclass correlation coefficient and SEM were used. κ Agreement was calculated for the visual assessment of 39 subjects using photographs and radiographs between 2 raters. Good to excellent intrarater and interrater intraclass correlation coefficient values were found on both photographs and radiographs. Interrater SEM was large and clinically significant for cervical lordosis photogrammetry and for 1 angle measuring cervical lordosis on radiographs. Interrater κ agreement for the visual assessment using photographs was poor (κ = 0.37). The raters were reliable to measure angles in photographs and radiographs to quantify craniocervical posture with exception of 2 angles measuring lordosis of the cervical spine when compared between raters. The visual assessment of posture between raters was not reliable. © 2013. Published by National University of Health Sciences All rights reserved.

  1. Special photographic emulsions for high LET dosimetry

    International Nuclear Information System (INIS)

    Katz, R.

    1978-12-01

    The purpose of these investigations into photographic emulsion dosimetry is to attempt to use the photographic emulsion to mimic the response of human tissues to high LET radiations. The program therefore requires that a systematic understanding of the response of mammalian cells to ionizing radiations be achieved. We have been concerned with differences in RBE and in radiation response to both high and LET radiations, and in the interrelationship between observations with these different radiations

  2. Sample handling and contamination encountered when coupling offline normal phase high performance liquid chromatography fraction collection of petroleum samples to Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Oro, Nicole E; Whittal, Randy M; Lucy, Charles A

    2012-09-05

    Normal phase high performance liquid chromatography (HPLC) is used to separate a gas oil petroleum sample, and the fractions are collected offline and analyzed on a high resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FT-ICR MS). The separation prior to MS analysis dilutes the sample significantly; therefore the fractions need to be prepared properly to achieve the best signal possible. The methods used to prepare the HPLC fractions for MS analysis are described, with emphasis placed on increasing the concentration of analyte species. The dilution effect also means that contamination in the MS spectra needs to be minimized. The contamination from molecular sieves, plastics, soap, etc. and interferences encountered during the offline fraction collection process are described and eliminated. A previously unreported MS contamination of iron formate clusters with a 0.8 mass defect in positive mode electrospray is also described. This interference resulted from the stainless steel tubing in the HPLC system. Contamination resulting from what has tentatively been assigned as palmitoylglycerol and stearoylglycerol was also observed; these compounds have not previously been reported as contaminant peaks. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Gaussian vs. Bessel light-sheets: performance analysis in live large sample imaging

    Science.gov (United States)

    Reidt, Sascha L.; Correia, Ricardo B. C.; Donnachie, Mark; Weijer, Cornelis J.; MacDonald, Michael P.

    2017-08-01

    Lightsheet fluorescence microscopy (LSFM) has rapidly progressed in the past decade from an emerging technology into an established methodology. This progress has largely been driven by its suitability to developmental biology, where it is able to give excellent spatial-temporal resolution over relatively large fields of view with good contrast and low phototoxicity. In many respects it is superseding confocal microscopy. However, it is no magic bullet and still struggles to image deeply in more highly scattering samples. Many solutions to this challenge have been presented, including, Airy and Bessel illumination, 2-photon operation and deconvolution techniques. In this work, we show a comparison between a simple but effective Gaussian beam illumination and Bessel illumination for imaging in chicken embryos. Whilst Bessel illumination is shown to be of benefit when a greater depth of field is required, it is not possible to see any benefits for imaging into the highly scattering tissue of the chick embryo.

  4. A histogram-based technique for rapid vector extraction from PIV photographs

    Science.gov (United States)

    Humphreys, William M., Jr.

    1991-01-01

    A new analysis technique, performed totally in the image plane, is proposed which rapidly extracts all available vectors from individual interrogation regions on PIV photographs. The technique avoids the need for using Fourier transforms with the associated computational burden. The data acquisition and analysis procedure is described, and results of a preliminary simulation study to evaluate the accuracy of the technique are presented. Recently obtained PIV photographs are analyzed.

  5. Photographic zoom fisheye lens design for DSLR cameras

    Science.gov (United States)

    Yan, Yufeng; Sasian, Jose

    2017-09-01

    Photographic fisheye lenses with fixed focal length for cameras with different sensor formats have been well developed for decades. However, photographic fisheye lenses with variable focal length are rare on the market due in part to the greater design difficulty. This paper presents a large aperture zoom fisheye lens for DSLR cameras that produces both circular and diagonal fisheye imaging for 35-mm sensors and diagonal fisheye imaging for APS-C sensors. The history and optical characteristics of fisheye lenses are briefly reviewed. Then, a 9.2- to 16.1-mm F/2.8 to F/3.5 zoom fisheye lens design is presented, including the design approach and aberration control. Image quality and tolerance performance analysis for this lens are also presented.

  6. Subjective memory complaints and cognitive performance in a sample of healthy elderly

    Directory of Open Access Journals (Sweden)

    Paulo Caramelli

    Full Text Available Abstract Memory loss is a major complaint among the elderly population. However, the clinical significance of this symptom is variable and also controversial in the scientific literature. Objective: To compare the cognitive performance of two groups of healthy elderly, one group with and the other without, subjective memory complaints (SMC. Methods: Sixty cognitively intact elderly individuals (39 females and 21 males, aged 69.9±6.3 years and with educational level of 8.5±5.5 years, were included in the study. Participants were submitted to the Mini-Mental State Examination and to the Cornell depression scale in order to rule out global cognitive impairment and depression, respectively. Moreover, they answered the MAC-Q, a questionnaire devised to evaluate subjective impression of memory function. Subsequently, they were submitted to the digit span forward and backward, the Brief Cognitive Screening Battery, and to the Frontal Assessment Battery. Results: Twenty-seven individuals had MAC-Q scores <25 and thus were classified as not having SMC, while 33 had MAC-Q scores ³25 and were considered to have SMC. No differences for age, gender, education and MMSE scores were found between the two groups. The comparison between the performance of the groups of complainers and non-complainers on the different cognitive tests yielded no significant difference, although there was a trend toward non-complainers performing better on incidental memory. Conclusions: The presence of SMC was not associated to objective memory impairment or to other cognitive deficits in this group of elderly individuals.

  7. Calibration of UFBC counters and their performance in the assay of large mass plutonium samples

    International Nuclear Information System (INIS)

    Verrecchia, G.P.D.; Smith, B.G.R.; Cranston, R.

    1991-01-01

    This paper reports on the cross-calibration of four Universal Fast Breeder reactor assembly coincidence (UFBC) counters using multi-can containers of Plutonium oxide powders with masses between 2 and 12 Kg of plutonium and a parametric study on the sensitivity of the detector response to the positioning or removal and substitution of the material with empty cans. The paper also reports on the performance of the UFBC for routine measurements on large mass, multi-can containers of plutonium oxide powders and compares the results to experience previously obtained in the measurement of fast reactor type fuel assemblies in the mass range 2 to 16 Kg of plutonium

  8. Performance and separation occurrence of binary probit regression estimator using maximum likelihood method and Firths approach under different sample size

    Science.gov (United States)

    Lusiana, Evellin Dewi

    2017-12-01

    The parameters of binary probit regression model are commonly estimated by using Maximum Likelihood Estimation (MLE) method. However, MLE method has limitation if the binary data contains separation. Separation is the condition where there are one or several independent variables that exactly grouped the categories in binary response. It will result the estimators of MLE method become non-convergent, so that they cannot be used in modeling. One of the effort to resolve the separation is using Firths approach instead. This research has two aims. First, to identify the chance of separation occurrence in binary probit regression model between MLE method and Firths approach. Second, to compare the performance of binary probit regression model estimator that obtained by MLE method and Firths approach using RMSE criteria. Those are performed using simulation method and under different sample size. The results showed that the chance of separation occurrence in MLE method for small sample size is higher than Firths approach. On the other hand, for larger sample size, the probability decreased and relatively identic between MLE method and Firths approach. Meanwhile, Firths estimators have smaller RMSE than MLEs especially for smaller sample sizes. But for larger sample sizes, the RMSEs are not much different. It means that Firths estimators outperformed MLE estimator.

  9. Spacelab-3 (STS-51B) Onboard Photograph

    Science.gov (United States)

    1985-01-01

    The primary purpose of the Spacelab-3 mission was to conduct materials science experiments in a stable low-gravity environment. In addition, the crew performed research in life sciences, fluid mechanics, atmospheric science, and astronomy. Spacelab-3 was equipped with several new minilabs, special facilities that would be used repeatedly on future flights. Two elaborate crystal growth furnaces, a life support and housing facility for small animals, and two types of apparatus for the study of fluids were evaluated on their inaugural flight. In this photograph, astronaut Don Lind observes the mercuric iodide growth experiment through a microscope at the vapor crystal growth furnace. The goals of this investigation were to grow near-perfect single crystals of mercuric iodide and to gain improved understanding of crystal growth by a vapor process. Mercuric iodide crystals have practical use as sensitive x-ray and gamma-ray detectors, and in portable detector devices for nuclear power plant monitoring, natural resource prospecting, biomedical applications in diagnosis and therapy, and in astronomical instruments. Managed by the Marshall Space Flight Center, Spacelab-3 (STS-51B) was launched aboard the Space Shuttle Orbiter Challenger on April 29, 1985.

  10. Determination of some organophosphorus pesticides in water and watermelon samples by microextraction prior to high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Chun; Wu, Qiuhua; Wu, Chunxia; Wang, Zhi

    2011-11-01

    A novel method based on simultaneous liquid-liquid microextraction and carbon nanotube reinforced hollow fiber microporous membrane solid-liquid phase microextraction has been developed for the determination of six organophosphorus pesticides, i.e. isocarbophos, phosmet, parathion-methyl, triazophos, fonofos and phoxim, in water and watermelon samples prior to high-performance liquid chromatography (HPLC). Under the optimum conditions, the method shows a good linearity within a range of 1-200 ng/mL for water samples and 5-200 ng/g for watermelon samples, with the correlation coefficients (r) varying from 0.9990 to 0.9997 and 0.9986 to 0.9995, respectively. The limits of detection (LODs) were in the range between 0.1 and 0.3 ng/mL for water samples and between 1.0 and 1.5 ng/g for watermelon samples. The recoveries of the method at spiking levels of 5.0 and 50.0 ng/mL for water samples were between 85.4 and 100.8%, and at spiking levels of 5.0 and 50.0 ng/g for watermelon samples, they were between 82.6 and 92.4%, with the relative standard deviations (RSDs) varying from 4.5-6.9% and 5.2-7.4%, respectively. The results suggested that the developed method represents a simple, low-cost, high analytes preconcentration and excellent sample cleanup procedure for the determination of organophosphorus pesticides in water and watermelon samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. 44 CFR 15.12 - Photographs and other depictions.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Photographs and other... NATIONAL EMERGENCY TRAINING CENTER § 15.12 Photographs and other depictions. (a) Photographs and other depictions at Mt. Weather. We prohibit taking photographs and making notes, sketches, or diagrams of...

  12. 8 CFR 1236.5 - Fingerprints and photographs.

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Fingerprints and photographs. 1236.5... ORDERED REMOVED Detention of Aliens Prior to Order of Removal § 1236.5 Fingerprints and photographs. Every... photographed. Such fingerprints and photographs shall be made available to Federal, State, and local law...

  13. 8 CFR 333.1 - Description of required photographs.

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Description of required photographs. 333.1 Section 333.1 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY NATIONALITY REGULATIONS PHOTOGRAPHS § 333.1 Description of required photographs. (a) Every applicant required to furnish photographs of...

  14. Registration of dental erosive wear on study models and intra-oral photographs.

    Science.gov (United States)

    Hove, L H; Mulic, A; Tveit, A B; Stenhagen, K R; Skaare, A B; Espelid, I

    2013-02-01

    Clinical photographs and study models may provide permanent records of dental erosion and be useful supplements to clinical registration. To assess the reliability and validity of registrations on clinical photographs and study models performed by a group of examiners. Thirty tooth surfaces were selected and assessed clinically, using the visual erosion dental examination system. The chosen surfaces provided the whole range of dental erosions including sound surfaces. The tooth surfaces were photographed and impressions were obtained for preparation of study models. Thirty-three dentists examined and scored the selected surfaces both on photographs and study models. The quality of diagnosis (AUC, area under curve) was slightly higher using photographs as compared to study models. The difference was statistically significant when the validation criterion was erosion, assuming dentine exposure. The inter-method agreement on photographs and study models versus the clinical evaluation were approximately in the same range with a mean κw of 0.48 and 0.43, respectively. When comparing study models with photographs the mean κw was 0.52. The intra-examiner agreement was strong/substantial for both (photographs mean κw = 0.63 and study models mean κw = 0.60). Linear weighted Cohen's kappa (κw) was used to evaluate inter-method and intra-examiner agreement. Receiver operating characteristic and area under the curves were used to express diagnostic quality according to a clinical examination. The results indicated that photographs were as good as study models for recording erosive lesions.

  15. Comprehensive sample analysis using high performance liquid chromatography with multi-detection.

    Science.gov (United States)

    Pravadali, Sercan; Bassanese, Danielle N; Conlan, Xavier A; Francis, Paul S; Smith, Zoe M; Terry, Jessica M; Shalliker, R Andrew

    2013-11-25

    Herein we assess the separation space offered by a liquid chromatography system with an optimised uni-dimensional separation for the determination of the key chemical entities in the highly complex matrix of a tobacco leaf extract. Multiple modes of detection, including UV-visible absorbance, chemiluminescence (acidic potassium permanganate, manganese(IV), and tris(2,2'-bipyridine)ruthenium(III)), mass spectrometry and DPPH radical scavenging were used in an attempt to systematically reduce the data complexity of the sample whilst obtaining a greater degree of molecule-specific information. A large amount of chemical data was obtained, but several limitations in the ability to assign detector responses to particular compounds, even with the aid of complementary detection systems, were observed. Thirty-three compounds were detected via MS on the tobacco extract and 12 out of 32 compounds gave a peak height ratio (PHR) greater than 0.33 on one or more detectors. This paper serves as a case study of these limitations, illustrating why multidimensional chromatography is an important consideration when developing a comprehensive chemical detection system. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Performance of an adult Brazilian sample on the Trail Making Test and Stroop Test

    Directory of Open Access Journals (Sweden)

    Kenia Repiso Campanholo

    Full Text Available ABSTRACT Objective: The Trail Making Test (TMT and Stroop Test (ST are attention tests widely used in clinical practice and research. The aim of this study was to provide normative data for the adult Brazilian population and to study the influence of gender, age and education on the TMT parts A and B, and ST cards A, B and C. Methods: We recruited 1447 healthy subjects aged ≥18 years with an educational level of 0-25 years who were native speakers of Portuguese (Brazilian. The subjects were evaluated by the Matrix Reasoning and Vocabulary subtests of the Wechsler Adult Intelligence Scale-III, along with the TMTA, TMTB and ST A, B and C. Results: Among the participants, mean intellectual efficiency was 103.20 (SD: 12.0, age 41.0 (SD: 16.4 years and education 11.9 (SD: 5.6 years. There were significant differences between genders on the TMTA (p=0.002, TMTB (p=0.017 and STC (p=0.024. Age showed a positive correlation with all attention tests, whereas education showed a negative correlation. Gender was not found to be significant on the multiple linear regression model, but age and education maintained their interference. Conclusion: Gender did not have the major impact on attentional tasks observed for age and education, both of which should be considered in the stratification of normative samples.

  17. False negative rate and other performance measures of a sponge-wipe surface sampling method for low contaminant concentrations.

    Energy Technology Data Exchange (ETDEWEB)

    Einfeld, Wayne; Krauter, Paula A.; Boucher, Raymond M.; Tezak, Mathew; Amidan, Brett G. (Pacific Northwest National Laboratory, Richland, WA); Piepel, Greg F. (Pacific Northwest National Laboratory, Richland, WA)

    2011-05-01

    Recovery of spores from environmental surfaces is known to vary due to sampling methodology, techniques, spore size and characteristics, surface materials, and environmental conditions. A series of tests were performed to evaluate a new, validated sponge-wipe method. Specific factors evaluated were the effects of contaminant concentrations and surface materials on recovery efficiency (RE), false negative rate (FNR), limit of detection (LOD) - and the uncertainties of these quantities. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show a roughly linear dependence of surface roughness on RE, where the smoothest surfaces have the highest mean RE values. REs were not influenced by the low spore concentrations tested (3 x 10{sup -3} to 1.86 CFU/cm{sup 2}). The FNR data were consistent with RE data, showing a trend of smoother surfaces resulting in higher REs and lower FNRs. Stainless steel generally had the lowest mean FNR (0.123) and plastic had the highest mean FNR (0.479). The LOD{sub 90} varied with surface material, from 0.015 CFU/cm{sup 2} on stainless steel up to 0.039 on plastic. Selecting sampling locations on the basis of surface roughness and using roughness to interpret spore recovery data can improve sampling. Further, FNR values, calculated as a function of concentration and surface material, can be used pre-sampling to calculate the numbers of samples for statistical sampling plans with desired performance, and post-sampling to calculate the confidence in characterization and clearance decisions.

  18. Performance assessment of refractory samples in the Los Alamos Controlled Air Incinerator

    International Nuclear Information System (INIS)

    Hutchins, D.A.; Borduin, L.C.; Koenig, R.A.; Vavruska, J.S.; Warner, C.L.

    1986-01-01

    A refractory evaluation project was initiated in 1979 to study the performance of six selected refractory materials within the Los Alamos Controlled Air Incinerator (CAI). Determining refractory resistance to thermal shock, chemical attack, and plutonium uptake was of particular interest. The experimental refractories were subjected to a variety of waste materials, including transuranic (TRU) contaminated wastes, highly chlorinated compounds and alkaline metal salts of perchlorate, chlorate, nitrate and oxylate, over the six year period of this study. Results of this study to date indicate that the use of high alumina, and possibly specialty plastic refractories, is advisable for the lining of incinerators used for the thermal destruction of diverse chemical compounds. 12 refs., 4 tabs

  19. Personality traits and theory of mind: Performance data of a Spanish sample of university students

    Directory of Open Access Journals (Sweden)

    José M. Gavilán

    2017-10-01

    Full Text Available This article allows consulting the performance data of 96 Spanish university students in two personality questionnaires and two theory of mind (ToM tasks. Personality dimensions were evaluated through the OPERAS questionnaire (Vigil-Colet et al., 2013 [1], which evaluates global personality through 5 scales: extraversion, agreeableness, conscientiousness, emotional stability, openness to experience, and the ESQUIZO-Q questionnaire (Fonseca-Pedrero et al., 2010 [2], which assesses schizotypy by means of 10 subscales: ideas of reference, magical thinking, unusual perceptual experiences, odd thinking and language, paranoid ideation, physical anhedonia, social anhedonia, odd behavior, lack of close friends, and excessive social anxiety. The ability to attribute/infer mental states, i.e. ToM, was measured through two computerized tasks: the revised Reading the Mind in the Eyes (Baron-Cohen et al., 1997, 2001 [3,4], and the Director's task (Keysar et al., 2000, 2003; Dumontheil et al., 2010 [5–7].

  20. Personality traits and theory of mind: Performance data of a Spanish sample of university students.

    Science.gov (United States)

    Gavilán, José M; Haro, Juan

    2017-10-01

    This article allows consulting the performance data of 96 Spanish university students in two personality questionnaires and two theory of mind (ToM) tasks. Personality dimensions were evaluated through the OPERAS questionnaire (Vigil-Colet et al., 2013) [1], which evaluates global personality through 5 scales: extraversion , agreeableness , conscientiousness , emotional stability , openness to experience , and the ESQUIZO-Q questionnaire (Fonseca-Pedrero et al., 2010) [2], which assesses schizotypy by means of 10 subscales: ideas of reference , magical thinking , unusual perceptual experiences , odd thinking and language , paranoid ideation , physical anhedonia , social anhedonia , odd behavior , lack of close friends , and excessive social anxiety . The ability to attribute/infer mental states, i.e. ToM, was measured through two computerized tasks: the revised Reading the Mind in the Eyes (Baron-Cohen et al., 1997, 2001) [3], [4], and the Director's task (Keysar et al., 2000, 2003; Dumontheil et al., 2010) [5-7].

  1. Workplace bullying and relationships with health and performance among a sample of New Zealand veterinarians.

    Science.gov (United States)

    Gardner, D H; Rasmussen, W

    2018-03-01

    To examine the relationships between workplace bullying, destructive leadership and team conflict, and physical health, strain, self-reported performance and intentions to quit among veterinarians in New Zealand, and how these relationships could be moderated by psychological capital and perceived organisational support. Data were collected by means of an online survey, distributed to members of the New Zealand Veterinary Association. Participation was voluntary and all responses were anonymous and confidential. Scores for the variables measured were based on responses to questions or statements with responses categorised on a linear scale. A series of regression analyses were used to assess mediation or moderation by intermediate variables on the relationships between predictor variables and dependent variables. Completed surveys were provided by 197 veterinarians, of which 32 (16.2%) had been bullied at work, i.e. they had experienced two or more negative acts at least weekly over the previous 6 months, and nine (4.6%) had experienced cyber-bullying. Mean scores for workplace bullying were higher for female than male respondents, and for non-managers than managers (pbullying were positively associated with scores for destructive leadership and team conflict, physical health, strain, and intentions to quit (pbullying and team conflict mediated the relationship between destructive leadership and strain, physical health and intentions to quit. Perceived organisational support moderated the effects of workplace bullying on strain and self-reported job performance (pbullied. The negative effects of destructive leadership on strain, physical health and intentions to quit were mediated by team conflict and workplace bullying. It should be noted that the findings of this study were based on a survey of self-selected participants and the findings may not represent the wider population of New Zealand veterinarians.

  2. Provenance study of obsidian samples by using portable and conventional X ray fluorescence spectrometers. Performance comparison of both instrumentations

    International Nuclear Information System (INIS)

    Cristina Vazquez

    2012-01-01

    The potentiality of portable instrumentation lies on the possibility of the in situ determinations. Sampling, packaging and transport of samples from the site to the laboratory are avoided and the analysis becomes non destructive at all. However, detection limits for light elements are, in most cases, a limitation for quantification purposes. In this work a comparison between the results obtained with an X ray fluorescence spectrometer laboratory based and a portable instrument is performed. A set of 76 obsidian archaeological specimens from northwest Patagonia, Argentina was used to carry out the study. Samples were collected in the area of the middle and high basin of the Limay River. The analytical information obtained with both instrumentations was complemented with Principal Component Analysis in order to define groups and identify provenance sources. The information from both instruments allows arriving to the same conclusion about sample provenance and mobility of hunter-gatherer groups. Three groups of sources were identified in both cases matching with the geographical information. Also, same sets of outlier samples or not associated to these sources were found. Artifact samples were associated mainly to the closest sources, but some of them are related to sources located more than three hundred kilometers, evidencing the large mobility of the hunter-gatherers by the obsidian interchange. No significant differences between concentrations values obtained by laboratory based instrument and portable one were found. (author)

  3. The reliability of test results from simple test samples in predicting the fatigue performance of automotive components

    International Nuclear Information System (INIS)

    Fourlaris, G.; Ellwood, R.; Jones, T.B.

    2007-01-01

    The use of high strength steels (HSS) in automotive components is steadily increasing as automotive designers use modern steel grades to improve structural performance, reduce vehicle weight and enhance crash performance. Weight reduction can be achieved by substituting mild steel with a thinner gauge HSS, however, it must be ensured that no deterioration in performance including fatigue capability occurs. In this study, tests have been carried out to determine the effects that gauge and material strength have on the fatigue performance of a fusion welded automotive suspension arm. Current finite element (FE) modelling and fatigue prediction techniques have been evaluated to determine their reliability when used for thin strip steels. Results have shown the fatigue performance of welded components to be independent of the strength of the parent material for the steel grades studied, with material thickness and joining process the key features determining the fatigue performance. The correlation between the fatigue performance of simple welded samples under uniaxial, constant amplitude loading and complex components under biaxial in service road load data, has been shown to be unreliable. This study also indicates that with the application of modern technologies, such as tailor-welded blanks (TWB), significant weight savings can be achieved. This is demonstrated by a 19% weight reduction with no detrimental effect on the fatigue performance

  4. [Study on the analytical methods of catechins in tea and green tea polyphenol samples by high performance liquid chromatography].

    Science.gov (United States)

    Dai, J; Wang, H X; Chen, S W; Tang, J

    2001-09-01

    Hypersil BDS C18 and Zorbax SB C18, suitable to separate simultaneously seven kinds of catechins and caffeine, were screened out from seven brands of reversed-phase columns. Mobile phase was a solution of methanol-water-acetic acid (or trifluoro acetic acid). Seven kinds of catechins in tea samples from six places in China and three green tea polyphenol(GTP) samples from different producers were separated and determined in 30 min by isocratic and gradient elutions. The effects of mobile phase components and temperature of column on retention parameters of catechins and caffeine are reviewed. Chromatographic conditions and pretreatment methods of samples were optimized. Gallocatechin gallate(GCG) and (-)-catechin gallate(CG) were identified by electrospray ionization mass spectrometry(ESI-MS) and prepared by high performance liquid chromatography for quantitative analysis. The other catechins, (-)-epigallocatechin (EGC), (+)-catechin (D-C), (-)-epicatechin(EC), (-)-epigallocatechin gallate(EGCG), (-)-epicatechin gallate(ECG) were identified with standards.

  5. Proposal of sampling protocols to verify possible performance objectives for Campylobacter species control in Italian broiler batches

    Directory of Open Access Journals (Sweden)

    Gerardo Manfreda

    2013-04-01

    Full Text Available Campylobacteriosis represents the most important food-borne illness in the EU. Broilers, as well as poultry meat, spread the majority of strains responsible for human cases. The main aims of this study were to suggest an approach for the definition of performance objectives (POs based on prevalence and concentration of Campylobacter species (spp. in broiler carcasses; moreover, sampling plans to determine the acceptability of broiler batches at the slaughterhouses in relation to such POs were formulated. The dataset used in this study was the one regarding Italy composed during the European Food Safety Authority baseline survey which was performed in the EU in 2008. A total of 393 carcasses obtained from 393 different batches collected from 48 Italian slaughterhouses were included in the analysis. Uncertainty in prevalence and concentration of Campylobacter spp. on carcasses was quantified assuming a beta and log normal distribution. Statistical analysis and distribution fitting were performed in ModelRisk v4.3 (Monte Carlo simulation with 10,000 iterations. By taking the 50th percentile of prevalence distribution as safety limit, sampling plans were subsequently calculated basing on the binomial approach. Final values of number of samples were equal to 4 or 5 to test with qualitative analysis. Considering a limit of quantification of 10 colony forming units/g, a higher number of samples (i.e. 10-13 would be necessary to test using enumeration. An increase of the sensibility of the analytical technique should be necessary to achieve realistic and useful sampling plans based on concentration data.

  6. Supercritical Fluid Extraction and Ultra Performance Liquid Chromatography of Respiratory Quinones for Microbial Community Analysis in Environmental and Biological Samples

    OpenAIRE

    Hanif, Muhammad; Atsuta, Yoichi; Fujie, Koichi; Daimon, Hiroyuki

    2012-01-01

    Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE) and ultra performance liquid chromatography (UPLC) method for the analysis of bacterial respiratory quinones (RQ) in environmental and biological samples. RQ profile analysi...

  7. Molecularly Imprinted Polymers (MIP for Selective Solid Phase Extraction of Celecoxib in Urine Samples Followed by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Saeedeh Ansari

    2017-09-01

    Full Text Available In this study, for the analysis of human urine samples, a novel method explained for the determination of celecoxib, a nonsteroidal anti-inflammatory drug (NSAID, using molecularly imprinted solid-phase extraction (MISPE coupled with high-performance liquid chromatography (HPLC. The synthesis of the MIP was performed by precipitation polymerization in methacrylic acid (MAA, ethylene glycol dimethacrylate (EGDMA, chloroform, 2,2′-azobisisobutyronitrile (AIBN and celecoxib as the functional monomer, cross-linker monomer, solvent, initiator and target drug, respectively. The celecoxib imprinted polymer was utilized as a specific sorbent for the solid phase extraction (SPE of celecoxib from samples. The molecularly imprinted polymer (MIP performance was compared with the synthesized non-molecularly imprinted polymer (NIP. Scanning electron microscopy (SEM, FT-IR spectroscopy, UV-VIS spectrophotometry and thermogravimetric analysis (TGA/DTG were used for characterizing the synthesized polymers. Moreover, the MISPE procedure parameters such as pH, eluent solvent flow rate, eluent volume and sorbent mass that probably influence the extraction process have been optimized to achieve the highest celecoxib extraction efficiency. The relative standard deviation (RSD %, recovery percent, limit of detection (LOD and limit of quantification (LOQ of this proposed method were 1.12%, 96%, 8 µg L-1 and 26.7 µg L-1, respectively. The proposed MISPE-HPLC-UV method can be used for the separation and enrichment of trace amounts of celecoxib in human urine and biological samples.

  8. Standards for illumination of digital prints and photographs

    International Nuclear Information System (INIS)

    Green, Phil

    2010-01-01

    Standards for illuminating digital prints and photographs have a number of quite different applications. In the graphic arts industry, the main applications are defined as appraisal and critical comparison, for which 500lux and 2000lux are specified in ISO 3664. In the museum world much lower levels of illumination are imposed when artefacts are considered to be prone to damage from such exposure. For display and storage of photographic prints, BS 5454:2000 is applicable and specifies maximum levels of 50 lux and 200 lux respectively. While these standards provide recommendations for exposure to radiant energy with the goal of limiting damage to materials and maximising visual discrimination, there is a need for more data on the radiative damage spectrum for the materials used in digital prints and photographs and other artefacts, and on the viewing conditions which can maximise visual performance for specific tasks. It is recommended that radiative exposure is measured in watts per square metre instead of lux to give a better indication of the propensity for radiative damage of a given illumination source.

  9. Reliable scar scoring system to assess photographs of burn patients.

    Science.gov (United States)

    Mecott, Gabriel A; Finnerty, Celeste C; Herndon, David N; Al-Mousawi, Ahmed M; Branski, Ludwik K; Hegde, Sachin; Kraft, Robert; Williams, Felicia N; Maldonado, Susana A; Rivero, Haidy G; Rodriguez-Escobar, Noe; Jeschke, Marc G

    2015-12-01

    Several scar-scoring scales exist to clinically monitor burn scar development and maturation. Although scoring scars through direct clinical examination is ideal, scars must sometimes be scored from photographs. No scar scale currently exists for the latter purpose. We modified a previously described scar scale (Yeong et al., J Burn Care Rehabil 1997) and tested the reliability of this new scale in assessing burn scars from photographs. The new scale consisted of three parameters as follows: scar height, surface appearance, and color mismatch. Each parameter was assigned a score of 1 (best) to 4 (worst), generating a total score of 3-12. Five physicians with burns training scored 120 representative photographs using the original and modified scales. Reliability was analyzed using coefficient of agreement, Cronbach alpha, intraclass correlation coefficient, variance, and coefficient of variance. Analysis of variance was performed using the Kruskal-Wallis test. Color mismatch and scar height scores were validated by analyzing actual height and color differences. The intraclass correlation coefficient, the coefficient of agreement, and Cronbach alpha were higher for the modified scale than those of the original scale. The original scale produced more variance than that in the modified scale. Subanalysis demonstrated that, for all categories, the modified scale had greater correlation and reliability than the original scale. The correlation between color mismatch scores and actual color differences was 0.84 and between scar height scores and actual height was 0.81. The modified scar scale is a simple, reliable, and useful scale for evaluating photographs of burn patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Examining gray matter structure associated with academic performance in a large sample of Chinese high school students.

    Science.gov (United States)

    Wang, Song; Zhou, Ming; Chen, Taolin; Yang, Xun; Chen, Guangxiang; Wang, Meiyun; Gong, Qiyong

    2017-04-18

    Achievement in school is crucial for students to be able to pursue successful careers and lead happy lives in the future. Although many psychological attributes have been found to be associated with academic performance, the neural substrates of academic performance remain largely unknown. Here, we investigated the relationship between brain structure and academic performance in a large sample of high school students via structural magnetic resonance imaging (S-MRI) using voxel-based morphometry (VBM) approach. The whole-brain regression analyses showed that higher academic performance was related to greater regional gray matter density (rGMD) of the left dorsolateral prefrontal cortex (DLPFC), which is considered a neural center at the intersection of cognitive and non-cognitive functions. Furthermore, mediation analyses suggested that general intelligence partially mediated the impact of the left DLPFC density on academic performance. These results persisted even after adjusting for the effect of family socioeconomic status (SES). In short, our findings reveal a potential neuroanatomical marker for academic performance and highlight the role of general intelligence in explaining the relationship between brain structure and academic performance.

  11. Development of the method of sensitivity improvement of photographic film applicable in high-energy physics experiments

    International Nuclear Information System (INIS)

    Gokieli, V.D.

    1986-01-01

    Sensitivity improvement of photographic films applicable in high-energy physics experiments is discussed. To get optimal operating conditions for photographic film PT-6 to check its physical properties on electron beam and in cosmic rays a set for film samples exposure in visible spectrum and in X-rays is constructed. The set includes a start up device, high-voltage pulse oscillator, shapers, a chamber for the sample exposure, voltage divider and electron oscillograph

  12. Performance of a Brazilian sample on the Portuguese translation of the BNI Screen for Higher Cerebral Functions.

    Science.gov (United States)

    Prigatano, George P; Souza, Lígia M N; Braga, Lucia W

    2018-03-01

    The Barrow Neurological Institute (BNI) Screen for Higher Cerebral Functions (BNIS) has been translated into several languages and found useful in evaluating multiple domains of cognitive and affective dysfunction, particularly in neuro-rehabilitation settings. Normative data from countries with high literacy rates have reported strikingly similar mean level of performance scores on this test, with age typically correlating higher with total score performance than education. In the present study, we obtain convenience sample normative data from a native Brazilian population on a Portuguese translation of the BNIS (i.e., BNIS-PT). The BNIS was translated into Portuguese by two native speaking Portuguese neuropsychologists who were also fluent in English. It was then administered to 201 normally functioning native Brazilian individuals who varied considerably in age and formal educational training. The mean BNIS total score was similar to what previous studies reported, but primarily in younger adults with at least 12 years of formal education. In this Brazilian sample, the correlation of educational level and BNIS total score was r = .68, p < .001. The correlation of age and BNIS total score was r = -.36, p < .001. This is the opposite pattern to that observed in previous standardization studies. The strong correlation of education with performance in various subtests was observed in all age groups (ages ranging from 15 to 85 years). This standardization study provides guidelines for calculating expected average performance levels on the BNIS-PT for Brazilian individuals with varying degrees of age and education. Educational level positively correlated with test performance on the BNIS-PT and was repeatedly observed to overshadow the effects of age, suggesting its important role in the development of higher cerebral functions in multiple domains in a Brazilian sample of normally functioning individuals.

  13. Performance of polymerase chain reaction for the diagnosis of cystic echinococcosis using serum, urine, and cyst fluid samples.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2014-01-01

    Cystic echinococcosis (CE) is a chronic zoonosis which presents with variable clinical manifestations. Currently the diagnosis of this disease is based on radiological findings and serological tests which lack specificity. Although antigen detection from the cyst fluid is the most specific, it is seldom done due to the complications involved. Detecting the presence of Echinococcus granulosus specific deoxyribonucleic acid (DNA) by the polymerase chain reaction (PCR) could provide a definitive diagnosis of CE. An in-house PCR assay was devised to detect E. granulosus specific DNA in serum, urine and hydatid cyst fluid. The ability of the PCR to detect E. granulosus in the above mentioned samples were observed in comparison with other antigen and antibody detection tests. Serum samples from surgically confirmed patients of CE with ruptured cysts contained the corresponding DNA while the in the majority of cases who had an intact cyst had no DNA of E. granulosus in their serum. DNA of E. granulosus was not found to be excreted in urine. PCR performed equal to antigen detection ELISA while testing hydatid cyst fluid samples. Serum and urine might not serve as useful samples for the molecular diagnosis of cystic echinococcosis. However, PCR can be useful on serum samples to detect ruptured hydatid cysts and on hydatid cyst fluid to confirm the parasitic diagnosis.

  14. Photographic program of a BWR for ALARA

    International Nuclear Information System (INIS)

    Dodd, A.M.; Parry, J.O.

    1984-01-01

    High radiation areas have often been photographed in commercial nuclear plants to identify radiation sources and equipment so workers having to go into the areas become familiar with them prior to entering. This helps minimize the workers' time in a high radiation area and is useful as a visual aid in training. Previous problems encountered in using this type of file included indexing, storing for long term use and reproducing photos for use in the field. At WNP-2, a program has been adopted from Aerojet of Idaho where negatives from photographs are mounted on computer aperture cards. The cards are coded to identify the equipment, physical location in the plant, reference drawings and other data. The aperture cards are reproduced using a process called Diazo. The information is put in a data file that can be sorted by any field on the card. A paper copy of the photo can be made in seconds on a machine similar to a dry silver copier, then mounted for training or maintenance purposes. The cost of duplicating the aperture cards and/or the paper copies is a fraction of that for reproducing color glossies. The computer data file provides cross-referencing to correlate the equipment with the photograph. The results are low cost, easy storage and easy access to the photograph file. Using this program, several thousand photographs can easily be stored and used

  15. Practicing IEF-PAGE of EPO: the impact of detergents and sample application methods on analytical performance in doping control.

    Science.gov (United States)

    Reichel, Christian

    2010-01-01

    Electrophoretic techniques, namely isoelectric focusing polyacrylamide gel electrophoresis (IEF-PAGE) and sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) are key techniques used for confirming the doping-related abuse of recombinant erythropoietins and analogs. IEF-PAGE is performed on horizontal slab-gels with samples applied to the surface of the gel. Different sample application techniques can be employed, but application pieces and applicator strips are most frequently used. However, defective application pieces cause lane streaking during IEF of erythropoietin (EPO), which is especially pronounced in the acidic region of the gel. The effect is due to an incompatibility of the substance used for enhancing the wettability of the cellulose-based commercial product and is batch-dependent. A detailed mass spectrometric study was performed, which revealed that defective sample application pieces (bought between 2007 and 2010) contained a complex mixture of alcohol ethoxylates, alcohol ethoxysulfates, and alkyl sulfates (e.g. SDS). Anionic detergents, like the sulfates contained in these application pieces, are in general incompatible with IEF. Alternative application techniques proved partly useful. While homemade pieces made of blotting paper are a good alternative, the usage of applicator strips or shims is hampered by the risk of leaking wells, which lead to laterally diffused samples. Casting IEF-gels with wells appears to be the best solution, since sustained release of retained proteins from the application pieces can be avoided. Edge effects do not occur if wells are correctly filled with the samples. The evaluation of EPO-profiles with defects is prohibited by the technical document on EPO-analytics (TD2009EPO) of the World Anti-Doping Agency (WADA). Copyright © 2010 John Wiley & Sons, Ltd.

  16. Nobels Nobels laureates photographed by Peter Badge

    CERN Document Server

    2008-01-01

    A unique photographic record of all living Nobel laureates. In this handsome coffee-table book, photographer Peter Badge captures the likeness of every living Nobel laureate in a lasting black-and-white image -- more than 300 striking portraits in all. Brief biographical sketches accompanying the large-scale photographs pay homage to each laureate's singular contribution to science, literature or world peace. Bringing readers face-to-face with Nelson Mandela, Jimmy Carter, the Dalai Lama, James Watson, Gabriel García Márquez, Toni Morrison, Rita Levi-Montalcini, Linda Buck, and Paul Samuelson among many others, NOBELS offers an intimate and compelling look at well-known honorees as well as lesser-known recipients. A fascinating word/image tableau.

  17. A Relational Ecology of Photographic Practices

    Directory of Open Access Journals (Sweden)

    Jacqui Knight

    2017-11-01

    Full Text Available This paper proposes a relational history of media artifacts, which decentralizes the dominance of the photographer or filmmaker as the absolute author of the work. It adds an alternative account to understanding the creative process and the subsequent study of media forms by discussing film and photographic practices as the reciprocal affective relationship between the maker, their intentions, materials, technologies, non-human agents and the environment. By reorganizing the anthropocentrism of art historical narratives, which typically exclude corporeality and materiality as drivers of human history, we are able to discuss the complex dynamic meshwork of determinants that bring photographic artifacts into existence: the lived, animate, vital materialism at once emergent and mixing of different causalities and temporalities.

  18. The influence of uncertainties of measurements in laboratory performance evaluation by intercomparison program in radionuclide analyses of environmental samples

    International Nuclear Information System (INIS)

    Tauhata, L.; Vianna, M.E.; Oliveira, A.E. de; Clain, A.F.; Ferreira, A.C.M.; Bernardes, E.M.

    2000-01-01

    The accuracy and precision of results of the radionuclide analyses in environmental samples are widely claimed internationally due to its consequences in the decision process coupled to evaluation of environmental pollution, impact, internal and external population exposure. These characteristics of measurement of the laboratories can be shown clearly using intercomparison data, due to the existence of a reference value and the need of three determinations for each analysis. In intercomparison studies accuracy in radionuclide assays in low-level environmental samples has usually been the main focus in performance evaluation and it can be estimated by taking into account the deviation between the experimental laboratory mean value and the reference value. The laboratory repeatability of measurements or their standard deviation is seldom included in performance evaluation. In order to show the influence of the uncertainties in performance evaluation of the laboratories, data of 22 intercomparison runs which distributed 790 spiked environmental samples to 20 Brazilian participant laboratories were compared, using the 'Normalised Standard Deviation' as statistical criteria for performance evaluation of U.S.EPA. It mainly takes into account the laboratory accuracy and the performance evaluation using the same data classified by normalised standard deviation modified by a weight reactor that includes the individual laboratory uncertainty. The results show a relative decrease in laboratory performance in each radionuclide assay: 1.8% for 65 Zn, 2.8% for 40 K, 3.4 for 60 Co, 3.7% for 134 Cs, 4.0% for 137 Cs, 4.4% for Th and U nat , 4.5% for 3 H, 6.3% for 133 Ba, 8.6% for 90 Sr, 10.6% for Gross Alpha, 10.9% for 106 Ru, 11.1% for 226 Ra, 11.5% for Gross Beta and 13.6% for 228 Ra. The changes in the parameters of the statistical distribution function were negligible and the distribution remained as Gaussian type for all radionuclides analysed. Data analyses in terms of

  19. Impacts of suppression on emotional responses and performance outcomes: an experience-sampling study in younger and older workers.

    Science.gov (United States)

    Yeung, Dannii Y; Fung, Helene H

    2012-11-01

    Past studies have demonstrated that older adults used less emotional suppression to regulate their emotions than did younger adults, but the effectiveness of using this emotion regulatory strategy on psychosocial well-being across age remains largely unexplored. The present study adopted an experience-sampling method to examine whether the impacts of momentary employment of emotional suppression on momentary positive and negative emotions and job performance would be different by age. Eighty-seven Chinese insurance workers, aged between 18 and 61 years, participated in a 5-day sampling study. Their affective responses at work, momentary task performance, and sales productivity were recorded. Results showed that older workers' greater use of suppression at work was associated with lower intensity of negative emotions, whereas such association was not found among younger workers. Moreover, greater use of suppression over the sampling period was significantly predictive of sales productivity of older workers, but such a positive association was not shown in younger workers. These findings reveal that the use of suppression at work may be more effective for older workers than for younger workers.

  20. Cloud chamber photographs of the cosmic radiation

    CERN Document Server

    Rochester, George Dixon

    1952-01-01

    Cloud Chamber Photographs of the Cosmic Radiation focuses on cloud chamber and photographic emulsion wherein the tracks of individual subatomic particles of high energy are studied. The publication first offers information on the technical features of operation and electrons and cascade showers. Discussions focus on the relationship in time and space of counter-controlled tracks; techniques of internal control of the cloud chamber; cascade processes with artificially-produced electrons and photons; and nuclear interaction associated with an extensive shower. The manuscript then elaborates on

  1. Development of Curriculum of Learning through Photograph

    Science.gov (United States)

    Suzuki, Keiko; Aoki, Naokazu; Kobayashi, Hiroyuki

    A curriculum of an integrated learning using power of photography in the junior highschool was constructed, and was experimented in the class "Seminar for Photographic Expression" of the integrated learning at a junior high school. The center of the curriculum is viewing photographs and self-expression using photography. By comparing the results of questionnaires investigation between before and after the class it is suggested that the curriculum brings about increase in self-esteem, empathy, and motivation for learning. This educational effect is really to foster ability to live self-sufficient lives. On the basis of these results curriculums which can be conducted by anyone at every junior highschool were proposed.

  2. Salvaging and Conserving Water Damaged Photographic Materials

    Science.gov (United States)

    Suzuki, Ryuji

    Degradation of water damaged photographic materials is discussed; the most vulnerable elements are gelatin layers and silver image. A simple and inexpensive chemical treatment is proposed, consisting of a bath containing a gelatin-protecting biocide and a silver image protecting agent. These ingredients were selected among those used in manufacturing of silver halide photographic emulsions or processing chemicals. Experiments confirmed that this treatment significantly reduced oxidative attacks to silver image and bacterial degradation of gelatin layers. The treated material was also stable under intense light fading test. Method of hardening gelatin to suppress swelling is also discussed.

  3. Determination of sulfonamides in butter samples by ionic liquid magnetic bar liquid-phase microextraction high-performance liquid chromatography.

    Science.gov (United States)

    Wu, Lijie; Song, Ying; Hu, Mingzhu; Xu, Xu; Zhang, Hanqi; Yu, Aimin; Ma, Qiang; Wang, Ziming

    2015-01-01

    A novel, simple, and environmentally friendly pretreatment method, ionic liquid magnetic bar liquid-phase microextraction, was developed for the determination of sulfonamides in butter samples by high-performance liquid chromatography. The ionic liquid magnetic bar was prepared by inserting a stainless steel wire into the hollow of a hollow fiber and immobilizing ionic liquid in the micropores of the hollow fiber. In the extraction process, the ionic liquid magnetic bars were used to stir the mixture of sample and extraction solvent and enrich the sulfonamides in the mixture. After extraction, the analyte-adsorbed ionic liquid magnetic bars were readily isolated with a magnet from the extraction system. It is notable that the present method was environmentally friendly since water and only several microliters of ionic liquid were used in the whole extraction process. Several parameters affecting the extraction efficiency were investigated and optimized, including the type of ionic liquid, sample-to-extraction solvent ratio, the number of ionic liquid magnetic bars, extraction temperature, extraction time, salt concentration, stirring speed, pH of the extraction solvent, and desorption conditions. The recoveries were in the range of 73.25-103.85 % and the relative standard deviations were lower than 6.84 %. The experiment results indicated that the present method was effective for the extraction of sulfonamides in high-fat content samples.

  4. Determination of polycyclic aromatic hydrocarbons in drinking water samples by solid-phase nanoextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Huiyong; Campiglia, Andres D

    2008-11-01

    A novel alternative is presented for the extraction and preconcentration of polycyclic aromatic hydrocarbons (PAH) from water samples. The new approachwhich we have named solid-phase nanoextraction (SPNE)takes advantage of the strong affinity that exists between PAH and gold nanoparticles. Carefully optimization of experimental parameters has led to a high-performance liquid chromatography method with excellent analytical figures of merit. Its most striking feature correlates to the small volume of water sample (500 microL) for complete PAH analyses. The limits of detection ranged from 0.9 (anthracene) to 58 ng.L (-1) (fluorene). The relative standard deviations at medium calibration concentrations vary from 3.2 (acenaphthene) to 9.1% (naphthalene). The analytical recoveries from tap water samples of the six regulated PAH varied from 83.3 +/- 2.4 (benzo[ k]fluoranthene) to 95.7 +/- 4.1% (benzo[ g,h,i]perylene). The entire extraction procedure consumes less than 100 microL of organic solvents per sample, which makes it environmentally friendly. The small volume of extracting solution makes SPNE a relatively inexpensive extraction approach.

  5. Supercritical fluid extraction and ultra performance liquid chromatography of respiratory quinones for microbial community analysis in environmental and biological samples.

    Science.gov (United States)

    Hanif, Muhammad; Atsuta, Yoichi; Fujie, Koichi; Daimon, Hiroyuki

    2012-03-05

    Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE) and ultra performance liquid chromatography (UPLC) method for the analysis of bacterial respiratory quinones (RQ) in environmental and biological samples. RQ profile analysis is one of the most widely used culture-independent tools for characterizing microbial community structure. A UPLC equipped with a photo diode array (PDA) detector was successfully applied to the simultaneous determination of ubiquinones (UQ) and menaquinones (MK) without tedious pretreatment. Supercritical carbon dioxide (scCO(2)) extraction with the solid-phase cartridge trap proved to be a more effective and rapid method for extracting respiratory quinones, compared to a conventional organic solvent extraction method. This methodology leads to a successful analytical procedure that involves a significant reduction in the complexity and sample preparation time. Application of the optimized methodology to characterize microbial communities based on the RQ profile was demonstrated for a variety of environmental samples (activated sludge, digested sludge, and compost) and biological samples (swine and Japanese quail feces).

  6. High-performance liquid chromatographic determination of histamine in biological samples: the cerebrospinal fluid challenge--a review.

    Science.gov (United States)

    Wang, Zhaopin; Wu, Juanli; Wu, Shihua; Bao, Aimin

    2013-04-24

    Histamine, a neurotransmitter crucially involved in a number of basic physiological functions, undergoes changes in neuropsychiatric disorders. Detection of histamine in biological samples such as cerebrospinal fluid (CSF) is thus of clinical importance. The most commonly used method for measuring histamine levels is high performance liquid chromatography (HPLC). However, factors such as very low levels of histamine, the even lower CSF-histamine and CSF-histamine metabolite levels, especially in certain neuropsychiatric diseases, rapid formation of histamine metabolites, and other confounding elements during sample collection, make analysis of CSF-histamine and CSF-histamine metabolites a challenging task. Nonetheless, this challenge can be met, not only with respect to HPLC separation column, derivative reagent, and detector, but also in terms of optimizing the CSF sample collection. This review aims to provide a general insight into the quantitative analyses of histamine in biological samples, with an emphasis on HPLC instruments, methods, and hyphenated techniques, with the aim of promoting the development of an optimal and practical protocol for the determination of CSF-histamine and/or CSF-histamine metabolites. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Analysis of chlorpheniramine in human urine samples using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Mehdi Maham

    2014-09-01

    Full Text Available A simple and environmentally friendly microextraction technique was used for determination of chlorpheniramine (CPM, an antihistamine drug, in human urine samples using dispersive liquid-liquid microextraction (DLLME followed by high performance liquid chromatography with diode array detection (HPLC-DAD. In this extraction technique, an appropriate mixture of acetonitrile (disperser solvent and carbon tetrachloride (extraction solvent was rapidly injected into the urine sample containing the target analyte. Tiny droplets of extractant were formed and dispersed into the sample solution and then sedimented at the bottom of the conical test tube by centrifugation. Under optimal conditions, the calibration curve was linear in the range of 0.055-5.5 µg mL-1, with a detection limit of 16.5 ng mL-1. This proposed method was successfully applied to the analysis of real urine samples. Low consumption of toxic organic solvents, simplicity of operation, low cost and acceptable figures of merit are the main advantages of the proposed technique.

  8. Supercritical Fluid Extraction and Ultra Performance Liquid Chromatography of Respiratory Quinones for Microbial Community Analysis in Environmental and Biological Samples

    Directory of Open Access Journals (Sweden)

    Koichi Fujie

    2012-03-01

    Full Text Available Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE and ultra performance liquid chromatography (UPLC method for the analysis of bacterial respiratory quinones (RQ in environmental and biological samples. RQ profile analysis is one of the most widely used culture-independent tools for characterizing microbial community structure. A UPLC equipped with a photo diode array (PDA detector was successfully applied to the simultaneous determination of ubiquinones (UQ and menaquinones (MK without tedious pretreatment. Supercritical carbon dioxide (scCO2 extraction with the solid-phase cartridge trap proved to be a more effective and rapid method for extracting respiratory quinones, compared to a conventional organic solvent extraction method. This methodology leads to a successful analytical procedure that involves a significant reduction in the complexity and sample preparation time. Application of the optimized methodology to characterize microbial communities based on the RQ profile was demonstrated for a variety of environmental samples (activated sludge, digested sludge, and compost and biological samples (swine and Japanese quail feces.

  9. Trestima – Digital Photographs for Forest Inventory

    Directory of Open Access Journals (Sweden)

    T. Rouvinen

    2014-10-01

    Full Text Available Higher efficiency of forest survey is a corner stone of forest inventory and forest planning. Mobile technologies create a unique opportunity to solve the problem as well as measurement accuracy improvement, higher data objectiveness and independent control of the results. Trestima technology bases on extraction of forest attributes such as basal area, tree stem diameter, tree height and species distribution from photographs captured by a mobile phone. Image processing is performed automatically in a cloud service using machine vision, which is aided by a human operator when necessary. That allows automating all further calculations. Functions of electronic compass and geopositioning implemented on modern smart-phones allows registering the direction as well as sufficiently accurate geographic coordinates, which enables unambiguously association of a measurement and its location. The service produces reports about timber stock, basal area, average diameter, average height, number of tree trunks and diameter distribution. The report prepared for each tree stand includes standard error, as well as confidence interval for the measurements results and the assessment, with a 95 % probability level. Using thecross-section area, the average diameter and average height, the timber stock and the number of stems in the specific area may be calculated. The report generated by Trestima can be easily supplemented by a derived parameters, as well as any of the applicable formulas can be easily modified or altered in accordance with the needs, for example, dependingon the particularforest inventory area. One of the key features of the Trestima technology is the fact that each measurement contains geographic coordinates’ data. It means that, the location of eachmeasurementcan be displayedon the map, and the route, and the area cover under consideration can be analyzed.

  10. Signal processing of data from short sample tests for the projection of conductor performance in ITER magnets

    International Nuclear Information System (INIS)

    Martovetsky, Nicolai

    2008-01-01

    Qualification of the ITER conductor is absolutely necessary. Testing large scale conductors is expensive and time-consuming. To test 3-4 m long straight samples in a bore of a split solenoid is a relatively economical way in comparison with the fabrication of a coil to be tested in a bore of a background field solenoid. However, testing short samples may give ambiguous results due to different constraints in current redistribution in the cable or other end effects which are not present in the large magnet. This paper discusses the processes taking place in the ITER conductor, conditions when conductor performance could be distorted and possible signal processing to deduce the behaviour of ITER conductors in ITER magnets from the test data

  11. Errors induced in the measurement and azimuth directions of morphological features imaged on oblique Lunar Orbiter photographs

    Science.gov (United States)

    Siegal, B. S.

    1974-01-01

    Many quantitative lunar studies, e.g., the morphology and dimensions of craters, crater density and distribution, have been performed using oblique Lunar Orbiter photographs. If the inherent change in scale and azimuth direction of features imaged on these photographs are not corrected, the measurement can be in considerable error and the resulting statistical inferences may be invalid. The magnitude of this error is dependent upon: the depression angle of the camera, the flight height of the spacecraft, the focal length of the camera, and the position and orientation of the object on the ground. The errors introduced by using unrectified oblique photographs as though they were vertical photographs are examined for several Lunar Orbiter high resolution NASA LRC Enhancement photographic prints taken at various depression angles.

  12. A comparison of photographic, replication and direct clinical examination methods for detecting developmental defects of enamel

    Directory of Open Access Journals (Sweden)

    Pakshir Hamid-Reza

    2011-04-01

    Full Text Available Abstract Background Different methods have been used for detecting developmental defects of enamel (DDE. This study aimed to compare photographic and replication methods with the direct clinical examination method for detecting DDE in children's permanent incisors. Methods 110 8-10-year-old schoolchildren were randomly selected from an examined sample of 335 primary Shiraz school children. Modified DDE index was used in all three methods. Direct examinations were conducted by two calibrated examiners using flat oral mirrors and tongue blades. Photographs were taken using a digital SLR camera (Nikon D-80, macro lens, macro flashes, and matt flash filters. Impressions were taken using additional-curing silicon material and casts made in orthodontic stone. Impressions and models were both assessed using dental loupes (magnification=x3.5. Each photograph/impression/cast was assessed by two calibrated examiners. Reliability of methods was assessed using kappa agreement tests. Kappa agreement, McNemar's and two-sample proportion tests were used to compare results obtained by the photographic and replication methods with those obtained by the direct examination method. Results Of the 110 invited children, 90 were photographed and 73 had impressions taken. The photographic method had higher reliability levels than the other two methods, and compared to the direct clinical examination detected significantly more subjects with DDE (P = 0.002, 3.1 times more DDE (P Conclusion The photographic method was much more sensitive than direct clinical examination in detecting DDE and was the best of the three methods for epidemiological studies. The replication method provided less information about DDE compared to photography. Results of this study have implications for both epidemiological and detailed clinical studies on DDE.

  13. Implementation trial of high performance trace analysis/environmental sampling (HPTA/ES) in uranium centrifuge enrichment plants

    International Nuclear Information System (INIS)

    Nackaerts, H.; Kloeckner, W.; Landresse, G.; MacLean, F.; Betti, M.; Forcina, V.; Hiernaut, T.; Tamborini, G.; Koch, L.; Schenkel, R.

    1999-01-01

    Field trials have demonstrated that the analysis of particles upon swipes obtained from inside nuclear installations provides clear signatures of past operations in that installation. This can offer a valuable tool for gaining assurance regarding the compliance with declared activities and the absence of undeclared activities (e.g. enrichment, reprocessing, and reactor operation) at such sites. This method, known as 'Environmental Sampling' (ES) or 'High Performance Trace Analysis' (HPTA) in EURATOM terminology, is at present being evaluated by the EURATOM Safeguards Directorate (ESD) in order to assess its possible use in nuclear installations within the European Union. It is expected that incorporation of HPTA/ES of sample collection and analysis into routine inspection activities will allow EURATOM to improve the effectiveness of safeguards in these installations and hopefully save inspection resources as well. The EURATOM Safeguards Directorate has therefore performed implementation trials involving the collection of particles by the so-called swipe sampling method in uranium centrifuge enrichment plants and hot cells in the European Union. These samples were subsequently analysed by the Joint Research Centre, Institute for Transuranium Elements (ITU) in Karlsruhe. Sampling points were chosen on the basis of the activities performed in the vicinity and by considering the possible ways through which particles are released, diffused and transported. The aim was to test the efficiency of the method as regards: the collection of enough representative material; the identification of a large enough number of uranium particles; the accurate measurement of the enrichment of the uranium particles found on the swipe; the representativity of the results in respect of past activities in the plant; the capability of detecting whether highly enriched uranium has been produced, used or occasionally transported in a location where low enriched uranium is routinely produced in

  14. An Investigation into Japine Platinum Photographs: William Willis´s Proprietary Paper

    DEFF Research Database (Denmark)

    Vila, Anna; Clark, Matthew L; McCabe, Constance

    2015-01-01

    and are essentially unknown to modern-day scholars who may mistake them as prints with thin binder layers, such as albumen or gelatin. Indeed, the approach to conservation of these photographs may differ from one designed for a traditional platinum print. The parchmentized Japine paper was criticized for its tendency......Analyses of two samples of the commercial platinum photographic paper “Japine” revealed that this trade-name product was sold with a range of surface properties from matte to glossy. An in-depth examination of an unprocessed glossy Japine sample showed a chemically modified surface resulting from...... parchmentization by treatment with sulfuric acid. This treatment results in a thin film of amorphous cellulose on the printing surface, altering its visual appearance and wet strength. Photographers selected this paper due to its aesthetic qualities. However, such papers have never been characterized...

  15. Automated detection of actinic keratoses in clinical photographs.

    Science.gov (United States)

    Hames, Samuel C; Sinnya, Sudipta; Tan, Jean-Marie; Morze, Conrad; Sahebian, Azadeh; Soyer, H Peter; Prow, Tarl W

    2015-01-01

    Clinical diagnosis of actinic keratosis is known to have intra- and inter-observer variability, and there is currently no non-invasive and objective measure to diagnose these lesions. The aim of this pilot study was to determine if automatically detecting and circumscribing actinic keratoses in clinical photographs is feasible. Photographs of the face and dorsal forearms were acquired in 20 volunteers from two groups: the first with at least on actinic keratosis present on the face and each arm, the second with no actinic keratoses. The photographs were automatically analysed using colour space transforms and morphological features to detect erythema. The automated output was compared with a senior consultant dermatologist's assessment of the photographs, including the intra-observer variability. Performance was assessed by the correlation between total lesions detected by automated method and dermatologist, and whether the individual lesions detected were in the same location as the dermatologist identified lesions. Additionally, the ability to limit false positives was assessed by automatic assessment of the photographs from the no actinic keratosis group in comparison to the high actinic keratosis group. The correlation between the automatic and dermatologist counts was 0.62 on the face and 0.51 on the arms, compared to the dermatologist's intra-observer variation of 0.83 and 0.93 for the same. Sensitivity of automatic detection was 39.5% on the face, 53.1% on the arms. Positive predictive values were 13.9% on the face and 39.8% on the arms. Significantly more lesions (p<0.0001) were detected in the high actinic keratosis group compared to the no actinic keratosis group. The proposed method was inferior to assessment by the dermatologist in terms of sensitivity and positive predictive value. However, this pilot study used only a single simple feature and was still able to achieve sensitivity of detection of 53.1% on the arms.This suggests that image analysis is

  16. On the reverse. Some notes on photographic images from the Warburg Institute Photographic Collection

    Directory of Open Access Journals (Sweden)

    Katia Mazzucco

    2012-10-01

    Full Text Available How can the visual and textual data about an image – the image of a work of art – on recto and verso of a picture be interpreted? An analogical-art-documentary photograph represents a palimpsest to be considered layer by layer. The examples discussed in this article, which refer to both Aby Warburg himself and the first nucleus of the Warburg Institute Photographic Collection, contribute to effectively outline elements of the debate around the question of the photographic reproduction of the work of art as well as of the position of photography in relation to the perception of the work of art.

  17. Determination of technetium-99 in soil samples by high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Muto, Toshio; Shimokawa, Toshinari

    1997-01-01

    A new powerful analytical technique viz. high performance liquid chromatography(HPLC) coupled to inductively coupled plasma mass spectrometry(HPLC/ICP-MS) has been applied to the determination of technetium-99( 99 Tc) in soils as a typical environmental sample. Technetium was enriched in a solution from incinerated soil samples by leaching in HNO 3 and passed through 'TEVA resin' column. The solution was injected into HPLC/ICP-MS system to eliminate the interfering elements (i.e. Ru and Mo) and to determine the 99 Tc concentration at the same time. The concentrations of 99 Tc in the incinerated soils were found to be 0.49Bq/kg(0.77ng/kg)-1.4Bq/kg(2.2ng/kg) with the determination limit of 0.02Bq/kg(0.03ng/kg(0.03ppt)). The results indicate the following findings; 1) the determination of 99 Tc by ICP-MS after strict elimination of the interfering elements by HPLC brings about the improvement in their reliability; 2) the detection limits identified are much lower compared with those by conventional ICP-MS methods because of the concentration of 99 Tc to smaller volume, which is due to only 100μl of samples could be measured by HPLC/ICP-MS system; 3) sample preparation could be simplified because of strict elimination of the interfering elements by HPLC. This research showed that HPLC/ICP-MS system is very effective to determine 99 Tc in environmental samples. (author)

  18. Determination of rare earth elements in water ore and grass sample around monazite dressing plant by high performance liquid chromatography

    International Nuclear Information System (INIS)

    Laoharojanaphand, S.

    1993-01-01

    High performance liquid chromatography technique for the analysis of rare earth elements; yttrium, cerium and lanthanum, was developed. A comparison of two mobile phases between α-hydroxy isobutyric acid and mandelic acid was carried out using C 1 8 column for separation and the amount of the rare earth elements were detected by post column complex formation with Arsenazo III. It was found that α-hydroxy isobutyric acid had higher efficiency in separation of the rare earth elements than mandelic acid when 1-octanesulfonic acid was used as an organic modifier. The optimum conditions of the mobile phase were comprised of the p H of 3.65, a flow rate of 1 ml/min which resulted in the values of resolution to be 13.62 between yttrium and cerium and 3.49 between cerium and lanthanum. Standard curves of yttrium and lanthanum yielded linear range of 0.1-45 and 1-60 ppm whereas the cerium curve was in the range of 1-100 ppm. The analyses of water, ore and grass samples collected around the monazite dressing plants from Prachuap Khiri Khan and Phuket showed that none of the rare earth elements was detected in all samples from Prachuap Khiri Khan. But 0.5 ppm of yttrium and 1.5 ppm of lanthanum were found in the water samples from Phuket while in the grass samples contained yttrium and cerium in the amounts of 2 ppm and 14 ppm whereas none was detected in the ore samples by this technique under the previous conditions

  19. Cryptography Would Reveal Alterations In Photographs

    Science.gov (United States)

    Friedman, Gary L.

    1995-01-01

    Public-key decryption method proposed to guarantee authenticity of photographic images represented in form of digital files. In method, digital camera generates original data from image in standard public format; also produces coded signature to verify standard-format image data. Scheme also helps protect against other forms of lying, such as attaching false captions.

  20. Astronaut Ronald Evans photographed during transearth coast EVA

    Science.gov (United States)

    1972-01-01

    Astronaut Ronald E. Evans is photographed performing extravehicular activity (EVA) during the Apollo 17 spacecraft's transearth coast. During his EVA Command Module pilot Evans retrieved film cassettes from the Lunar Sounder, Mapping Camera, and Panoramic Camera. The total time for the transearth EVA was one hour seven minutes 19 seconds, starting at ground elapsed time of 257:25 (2:28 p.m.) amd ending at ground elapsed time of 258:42 (3:35 p.m.) on Sunday, December 17, 1972.

  1. Performance of optimized McRAPD in identification of 9 yeast species frequently isolated from patient samples: potential for automation.

    Science.gov (United States)

    Trtkova, Jitka; Pavlicek, Petr; Ruskova, Lenka; Hamal, Petr; Koukalova, Dagmar; Raclavsky, Vladislav

    2009-11-10

    Rapid, easy, economical and accurate species identification of yeasts isolated from clinical samples remains an important challenge for routine microbiological laboratories, because susceptibility to antifungal agents, probability to develop resistance and ability to cause disease vary in different species. To overcome the drawbacks of the currently available techniques we have recently proposed an innovative approach to yeast species identification based on RAPD genotyping and termed McRAPD (Melting curve of RAPD). Here we have evaluated its performance on a broader spectrum of clinically relevant yeast species and also examined the potential of automated and semi-automated interpretation of McRAPD data for yeast species identification. A simple fully automated algorithm based on normalized melting data identified 80% of the isolates correctly. When this algorithm was supplemented by semi-automated matching of decisive peaks in first derivative plots, 87% of the isolates were identified correctly. However, a computer-aided visual matching of derivative plots showed the best performance with average 98.3% of the accurately identified isolates, almost matching the 99.4% performance of traditional RAPD fingerprinting. Since McRAPD technique omits gel electrophoresis and can be performed in a rapid, economical and convenient way, we believe that it can find its place in routine identification of medically important yeasts in advanced diagnostic laboratories that are able to adopt this technique. It can also serve as a broad-range high-throughput technique for epidemiological surveillance.

  2. Multi-domain computerized cognitive training program improves performance of bookkeeping tasks: a matched-sampling active-controlled trial.

    Science.gov (United States)

    Lampit, Amit; Ebster, Claus; Valenzuela, Michael

    2014-01-01

    Cognitive skills are important predictors of job performance, but the extent to which computerized cognitive training (CCT) can improve job performance in healthy adults is unclear. We report, for the first time, that a CCT program aimed at attention, memory, reasoning and visuo-spatial abilities can enhance productivity in healthy younger adults on bookkeeping tasks with high relevance to real-world job performance. 44 business students (77.3% female, mean age 21.4 ± 2.6 years) were assigned to either (a) 20 h of CCT, or (b) 20 h of computerized arithmetic training (active control) by a matched sampling procedure. Both interventions were conducted over a period of 6 weeks, 3-4 1-h sessions per week. Transfer of skills to performance on a 60-min paper-based bookkeeping task was measured at three time points-baseline, after 10 h and after 20 h of training. Repeated measures ANOVA found a significant Group X Time effect on productivity (F = 7.033, df = 1.745; 73.273, p = 0.003) with a significant interaction at both the 10-h (Relative Cohen's effect size = 0.38, p = 0.014) and 20-h time points (Relative Cohen's effect size = 0.40, p = 0.003). No significant effects were found on accuracy or on Conners' Continuous Performance Test, a measure of sustained attention. The results are discussed in reference to previous findings on the relationship between brain plasticity and job performance. Generalization of results requires further study.

  3. Multi-domain computerized cognitive training program improves performance of bookkeeping tasks: a matched-sampling active-controlled trial

    Directory of Open Access Journals (Sweden)

    Amit eLampit

    2014-07-01

    Full Text Available Cognitive skills are important predictors of job performance, but the extent to which Computerized Cognitive Training (CCT can improve job performance in healthy adults is unclear. We report, for the first time, that a CCT program aimed at attention, memory, reasoning and visuo-spatial abilities can enhance productivity in healthy younger adults on bookkeeping tasks with high relevance to real-world job performance. 44 business students (77.3% female, mean age 21.4 ± 2.6 years were assigned to either (a 20 hours of CCT, or (b 20 hours of computerized arithmetic training (active control by a matched sampling procedure. Both interventions were conducted over a period of six weeks, 3-4 one-hour sessions per week. Transfer of skills to performance on a 60-minute paper-based bookkeeping task was measured at three time points – baseline, after 10 hours and after 20 hours of training. Repeated measures ANOVA found a significant Group X Time effect on productivity (F=7.033, df=1.745; 73.273, p=0.003 with a significant interaction at both the 10-hour (Relative Cohen’s effect size = 0.38, p=0.014 and 20-hour time points (Relative Cohen’s effect size = 0.40, p=0.003. No significant effects were found on accuracy or on Conners’ Continuous Performance Test, a measure of sustained attention. The results are discussed in reference to previous findings on the relationship between brain plasticity and job performance. Generalization of results requires further study.

  4. The reliability of language performance measurement in language sample analysis of children aged 5-6 years

    Directory of Open Access Journals (Sweden)

    Zahra Soleymani

    2014-04-01

    Full Text Available Background and Aim: The language sample analysis (LSA is more common in other languages than Persian to study language development and assess language pathology. We studied some psychometric properties of language sample analysis in this research such as content validity of written story and its pictures, test-retest reliability, and inter-rater reliability.Methods: We wrote a story based on Persian culture from Schneider’s study. The validity of written story and drawn pictures was approved by experts. To study test-retest reliability, 30 children looked at the pictures and told their own story twice with 7-10 days interval. Children generated the story themselves and tester did not give any cue about the story. Their audio-taped story was transcribed and analyzed. Sentence and word structures were detected in the analysis.Results: Mean of experts' agreement with the validity of written story was 92.28 percent. Experts scored the quality of pictures high and excellent. There was correlation between variables in sentence and word structure (p<0.05 in test-retest, except complex sentences (p=0.137. The agreement rate was 97.1 percent in inter-rater reliability assessment of transcription. The results of inter-rater reliability of language analysis showed that correlation coefficients were significant.Conclusion: The results confirmed that the tool was valid for eliciting language sample. The consistency of language performance in repeated measurement varied from mild to high in language sample analysis approach.

  5. Comparing the performance of cluster random sampling and integrated threshold mapping for targeting trachoma control, using computer simulation.

    Directory of Open Access Journals (Sweden)

    Jennifer L Smith

    Full Text Available Implementation of trachoma control strategies requires reliable district-level estimates of trachomatous inflammation-follicular (TF, generally collected using the recommended gold-standard cluster randomized surveys (CRS. Integrated Threshold Mapping (ITM has been proposed as an integrated and cost-effective means of rapidly surveying trachoma in order to classify districts according to treatment thresholds. ITM differs from CRS in a number of important ways, including the use of a school-based sampling platform for children aged 1-9 and a different age distribution of participants. This study uses computerised sampling simulations to compare the performance of these survey designs and evaluate the impact of varying key parameters.Realistic pseudo gold standard data for 100 districts were generated that maintained the relative risk of disease between important sub-groups and incorporated empirical estimates of disease clustering at the household, village and district level. To simulate the different sampling approaches, 20 clusters were selected from each district, with individuals sampled according to the protocol for ITM and CRS. Results showed that ITM generally under-estimated the true prevalence of TF over a range of epidemiological settings and introduced more district misclassification according to treatment thresholds than did CRS. However, the extent of underestimation and resulting misclassification was found to be dependent on three main factors: (i the district prevalence of TF; (ii the relative risk of TF between enrolled and non-enrolled children within clusters; and (iii the enrollment rate in schools.Although in some contexts the two methodologies may be equivalent, ITM can introduce a bias-dependent shift as prevalence of TF increases, resulting in a greater risk of misclassification around treatment thresholds. In addition to strengthening the evidence base around choice of trachoma survey methodologies, this study illustrates

  6. Two-step microextraction combined with high performance liquid chromatographic analysis of pyrethroids in water and vegetable samples.

    Science.gov (United States)

    Mukdasai, Siriboon; Thomas, Chunpen; Srijaranai, Supalax

    2014-03-01

    Dispersive liquid microextraction (DLME) combined with dispersive µ-solid phase extraction (D-µ-SPE) has been developed as a new approach for the extraction of four pyrethroids (tetramethrin, fenpropathrin, deltamethrin and permethrin) prior to the analysis by high performance liquid chromatography (HPLC) with UV detection. 1-Octanol was used as the extraction solvent in DLME. Magnetic nanoparticles (Fe3O4) functionalized with 3-aminopropyl triethoxysilane (APTS) were used as the dispersive in DLME and as the adsorbent in D-µ-SPE. The extracted pyrethroids were separated within 30 min using isocratic elution with acetonitrile:water (72:28). The factors affecting the extraction efficiency were investigated. Under the optimum conditions, the enrichment factors were in the range of 51-108. Linearity was obtained in the range 0.5-400 ng mL(-1) (tetramethrin) and 5-400 ng mL(-1) (fenpropathrin, deltamethrin and permethrin) with the correlation coefficients (R(2)) greater than 0.995. Detection limits were 0.05-2 ng mL(-1) (water samples) and 0.02-2.0 ng g(-1) (vegetable samples). The relative standard deviations of peak area varied from 1.8 to 2.5% (n=10). The extraction recoveries of the four pyrethroids in field water and vegetable samples were 91.7-104.5%. The proposed method has high potential for use as a sensitive method for determination of pyrethroid residues in water and vegetable samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Chemometrics enhanced HPLC-DAD performance for rapid quantification of carbamazepine and phenobarbital in human serum samples.

    Science.gov (United States)

    Vosough, Maryam; Ghafghazi, Shiva; Sabetkasaei, Masoumeh

    2014-02-01

    This paper describes development and validation of a simple and efficient bioanalytical procedure for simultaneous determination of phenobarbital and carbamazepine in human serum samples using high performance liquid chromatography with photodiode-array detection (HPLC-DAD) regarding a fast elution methodology in less than 5 min. Briefly, this method consisted of a simple deproteinization step of serum samples followed by HPLC analysis on a Bonus-RP column using an isocratic mode of elution with acetonitrile/K2HPO4 (pH=7.5) buffer solution (45:55). Due to the presence of serum endogenous components as non-calibrated components in the sample, second-order calibration based on multivariate curve resolution-alternating least squares (MCR-ALS), has been applied on a set of absorbance matrices collected as a function of retention time and wavelengths. Acceptable resolution and quantification results were achieved in the presence of matrix interferences and the second-order advantage was fully exploited. The average recoveries for carbamazepine and phenobarbital were 89.7% and 86.1% and relative standard deviation values were lower than 9%. Additionally, computed elliptical joint confidence region (EJCR) confirmed the accuracy of the proposed method and indicated the absence of both constant and proportional errors in the predicted concentrations. The developed method enabled the determination of the analytes in different serum samples in the presence of overlapped profiles, while keeping experimental time and extraction steps at minimum. Finally, the serum concentration levels of carbamazepine in three time intervals were reported for morphine-dependents who had received carbamazepine for treating their neuropathic pain. © 2013 Elsevier B.V. All rights reserved.

  8. Photographic and drafting techniques simplify method of producing engineering drawings

    Science.gov (United States)

    Provisor, H.

    1968-01-01

    Combination of photographic and drafting techniques has been developed to simplify the preparation of three dimensional and dimetric engineering drawings. Conventional photographs can be converted to line drawings by making copy negatives on high contrast film.

  9. An interactive program for digitization of seabed photographs

    Digital Repository Service at National Institute of Oceanography (India)

    Ramprasad, T.; Sharma, R.

    A program for dignitization of seabed photographs to compute coverage and abundance of polymetallic nodules is developed. Since the objects in the seabed photograph are partially covered by thin sediment layer, the automatic scanning devices may...

  10. Time perception of action photographs is more precise than that of still photographs.

    Science.gov (United States)

    Moscatelli, Alessandro; Polito, Laura; Lacquaniti, Francesco

    2011-04-01

    A photograph of an action contains implicit information about the depicted motion. Previous studies using either psychophysics or neuroimaging suggested that the neural processing of implied-motion images shares some features of real-motion processing. According to the hypothesis that the target depicted in photographs with implied motion is mentally represented as continuing in motion, such kind of photographs should be processed by the brain similarly to the individual frames of a running movie. In order to decode the functional significance of a movie, we must be able to estimate the duration of each frame and the time interval between successive frames as precisely as possible. Therefore, under naturalistic conditions, one would expect that the precision of time duration estimates is higher for action pictures than for still pictures. To test this prediction, we asked human observers to compare the variable duration of test photographs with the reference duration of their scrambled version. We found that, as expected, the duration of photographs with implied motion was discriminated better than the duration of photographs without implied motion. We also found that the average reaction time for the discrimination of photographs with implied motion was longer than that for photographs without implied motion, suggesting that the processing of implied motion involves longer and/or slower neural routes to compute time duration. This longer processing may depend on the engagement of two visual systems in parallel, one for processing form and the other one for processing implied motion. The perceptual decision about time duration would occur after the convergence of signals from these two pathways.

  11. EEG and autonomic responses during performance of matching and non-matching to sample working memory tasks with emotional content.

    Directory of Open Access Journals (Sweden)

    Ana eGarcia

    2011-12-01

    Full Text Available Working memory (WM is a neural system responsible for the temporary storage of information and its utilization in problem solving. The central executive is theorized as the controller of storage functions that support WM. Neurophysiological data suggest that EEG theta and alpha oscillations in frontal and midline regions are involved in neural communication between the central executive and storage functions during WM performance. Emotion is known to modulate several memory systems, including WM, through central and peripheral pathways. However, the physiological correlations (electroencephalographic – EEG; autonomic nervous activity of the effect of emotion over WM are not well described. In this study we aimed to identify physiological responses related to emotional WM performance. EEG (21 channels, heart rate (HR and galvanic skin response (GSR recordings were obtained from 54 volunteers while performing delayed matching and non-matching to sample tasks (DMTS/DNMTS. Emotional and neutral pictures from the International Affective Picture System and geometric figures were used as stimuli. As expected, WM performance was accompanied by presence of theta (frontal and midline electrodes and Alpha power (parietal electrodes. Beta and gamma oscillations were concentrated in frontopolar and left temporal regions. DNMTS task was accompanied by increases in Beta power, HR and GSR compared to DMTS task. Correlation analysis showed a positive tendency for gamma in Fp2 site, ratio of LF/HF (HR low and high frequency and skin conductance in both tasks. The HR results indicate an inverse reaction related to parasympathetic and sympathetic nervous system during the performance of the tasks. Taken together, our results contribute to elucidate the complex interactions between central and autonomic nervous systems in the modulation of emotional WM tasks.

  12. Black-and-white photographic chemistry: A reference

    Science.gov (United States)

    Walker, E. D. (Compiler)

    1986-01-01

    This work is intended as a reference of black-and-white photographic chemistry. Included is a basic history of the photographic processes and a complete description of all chemicals used, formulas for the development and fixation process, and associated formulas such as cleaners, hardeners, and toners. The work contains a complete glossary of photographic terms, a trouble-shooting section listing causes and effects regarding photographic film and papers, and various conversion charts.

  13. Exploratory factor analysis of Kenny Music Performance Anxiety Inventory (K-MPAI in a Brazilian musician sample

    Directory of Open Access Journals (Sweden)

    Ana Elisa Medeiros Barbar

    2015-10-01

    Full Text Available Abstract Background The Kenny Music Performance Anxiety Inventory (K-MPAI is very significant among the available instruments which measures Musical Performance Anxiety (MPA. Objective The aim of this study is to find evidence of validity of the Kenny Music Performance Anxiety Inventory (K-MPAI, in its translated and adapted Brazilian version, through the study of its factor structure. Methods A convenience sample of 230 amateur musicians completed the K-MPAI. Results The initial factor analysis yielded eight factors, explaining 62.4% of variance. However, due to the factors’ composition and internal consistency values lower than 0.50, the number of factors was later set at three, considering the internal consistency of those, the theoretical propositions and symptomatology aspects that supported the construction of scale. They were named “Worries and insecurity” (α = 0.82, “Depression and hopelessness” (α = 0.77 and “Early parental relationships” (α = 0.57. Discussion/Conclusions These results point to the scale’s construct validity, since they support the theoretical basis used for the development of the K-MPAI and the clinical manifestations of the MPA.

  14. 8 CFR 236.5 - Fingerprints and photographs.

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Fingerprints and photographs. 236.5 Section... to Order of Removal § 236.5 Fingerprints and photographs. Every alien 14 years of age or older... photographs shall be made available to Federal, State, and local law enforcement agencies upon request to the...

  15. Best of Adobe Photoshop techniques and images from professional photographers

    CERN Document Server

    Hurter, Bill

    2006-01-01

    Bill Hurter is the editor of ""Rangefinder"" magazine, the former editor of ""Petersen's PhotoGraphic,"" and the author of ""The Best of Wedding Photography, Group Portrait Photography Handbook, The Portrait Photographer's Guide to Posing, ""and ""Portrait Photographer's Handbook. ""He lives in Santa Monica, California.

  16. The aesthetic appeal of depth of field in photographs

    NARCIS (Netherlands)

    Zhang, T.; Nefs, H.T.; Redi, J.; Heynderickx, I.E.J.

    2014-01-01

    We report here how depth of field (DOF) affects the aesthetic appeal of photographs for different content categories. 339 photographs spanning eight categories were selected from Flickr, Google+, and personal collections. First, we classified the 339 photographs into three levels of depth of field:

  17. Using Photographs to Integrate Liberal Arts Learning in Business Education

    Science.gov (United States)

    Madden, Laura T.; Smith, Anne D.

    2015-01-01

    The inclusion of photographic approaches in the business classroom can incorporate missing elements of liberal education into business education, which were highlighted in a recent Carnegie study of undergraduate business education. Building on photographic methods in social science research, we identify three categories of photographic approaches…

  18. 7 CFR 500.9 - Photographs for news or advertising.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Photographs for news or advertising. 500.9 Section 500... for news or advertising. Photographs for news purposes may be taken at the USNA without prior permission. Photographs for advertising and other commercial purposes may be taken, but only with the prior...

  19. Images of the Great Depression: A Photographic Essay.

    Science.gov (United States)

    Stevens, Robert L.; Fogel, Jared A.

    2001-01-01

    Provides background information on the Farm Security Administration (FSA) and the photographic section of the FSA. Identifies six photographers and features three photographers (Walker Evans, Dorothea Lange, and Ben Shahn) who were recruited to document farm conditions. Discusses using FSA photos in the classroom and provides lesson plans to help…

  20. Recognition Memory for Movement in Photographs: A Developmental Study.

    Science.gov (United States)

    Futterweit, Lorelle R.; Beilin, Harry

    1994-01-01

    Investigated whether children's recognition memory for movement in photographs is distorted forward in the direction of implied motion. When asked whether the second photograph was the same as or different from the first, subjects made more errors for test photographs showing the action slightly forward in time, compared with slightly backward in…

  1. Use of photographic film to estimate exposure near the Three Mile Island Nuclear Power Station

    International Nuclear Information System (INIS)

    Shuping, R.E.

    1981-02-01

    This report documents the methodology and results of a Bureau of Radiological Health study of the use of photographic film samples for estimating exposure levels near the Three Mile Island nuclear power station. The study was conducted to provide an independent assessment of the radiation levels near TMI following the accident on March 28, 1979

  2. Culture and importance of backgrounds: a cross-cultural study of photograph taking.

    Science.gov (United States)

    Zhang, Jie; Li, Chen; Smithson, Adam; Spann, Ethan; Ruan, Fang

    2010-10-01

    To compare the focus on targeted people while taking a photograph, samples of American and Chinese college students were randomly selected and asked to take casual pictures of people around them with digital cameras. About 200 photographs were rated for the focus on the intended target in the picture. American students were more likely to focus on the targeted individual, while the Chinese students were more likely to attend to the background and the environment of the targeted individual. The findings imply that for the Chinese college students, the environment can be equally important as the person. Possibly for Americans the environment is less important due to the more individualistic culture.

  3. Performance of the flow cytometric E-screen assay in screening estrogenicity of pure compounds and environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Vanparys, Caroline, E-mail: caroline.vanparys@ua.ac.be [Laboratory of Ecophysiology, Biochemistry and Toxicology, University of Antwerp, Antwerp (Belgium); Depiereux, Sophie; Nadzialek, Stephanie [Research Unit in Organismal Biology (URBO), University of Namur (FUNDP), Namur (Belgium); Robbens, Johan; Blust, Ronny [Laboratory of Ecophysiology, Biochemistry and Toxicology, University of Antwerp, Antwerp (Belgium); Kestemont, Patrick [Research Unit in Organismal Biology (URBO), University of Namur (FUNDP), Namur (Belgium); De Coen, Wim [Laboratory of Ecophysiology, Biochemistry and Toxicology, University of Antwerp, Antwerp (Belgium); European Chemicals Agency (ECHA), Helsinki (Finland)

    2010-09-15

    In vitro estrogenicity screens are believed to provide a first prioritization step in hazard characterization of endocrine disrupting chemicals. When applied to complex environmental matrices or mixture samples, they have been indicated valuable in estimating the overall estrogen-mimicking load. In this study, the performance of an adapted format of the classical E-screen or MCF-7 cell proliferation assay was profoundly evaluated to rank pure compounds as well as influents and effluents of sewage treatment plants (STPs) according to estrogenic activity. In this adapted format, flow cytometric cell cycle analysis was used to allow evaluation of the MCF-7 cell proliferative effects after only 24 h of exposure. With an average EC{sub 50} value of 2 pM and CV of 22%, this assay appears as a sensitive and reproducible system for evaluation of estrogenic activity. Moreover, estrogenic responses of 17 pure compounds corresponded well, qualitatively and quantitatively, with other in vitro and in vivo estrogenicity screens, such as the classical E-screen (R{sup 2} = 0.98), the estrogen receptor (ER) binding (R{sup 2} = 0.84) and the ER transcription activation assay (R{sup 2} = 0.87). To evaluate the applicability of this assay for complex samples, influents and effluents of 10 STPs covering different treatment processes, were compared and ranked according to estrogenic removal efficiencies. Activated sludge treatment with phosphorus and nitrogen removal appeared most effective in eliminating estrogenic activity, followed by activated sludge, lagoon and filter bed. This is well in agreement with previous findings based on chemical analysis or biological activity screens. Moreover, ER blocking experiments indicated that cell proliferative responses were mainly ER mediated, illustrating that the complexity of the end point, cell proliferation, compared to other ER screens, does not hamper the interpretation of the results. Therefore, this study, among other E-screen studies

  4. Performance of the flow cytometric E-screen assay in screening estrogenicity of pure compounds and environmental samples

    International Nuclear Information System (INIS)

    Vanparys, Caroline; Depiereux, Sophie; Nadzialek, Stephanie; Robbens, Johan; Blust, Ronny; Kestemont, Patrick; De Coen, Wim

    2010-01-01

    In vitro estrogenicity screens are believed to provide a first prioritization step in hazard characterization of endocrine disrupting chemicals. When applied to complex environmental matrices or mixture samples, they have been indicated valuable in estimating the overall estrogen-mimicking load. In this study, the performance of an adapted format of the classical E-screen or MCF-7 cell proliferation assay was profoundly evaluated to rank pure compounds as well as influents and effluents of sewage treatment plants (STPs) according to estrogenic activity. In this adapted format, flow cytometric cell cycle analysis was used to allow evaluation of the MCF-7 cell proliferative effects after only 24 h of exposure. With an average EC 50 value of 2 pM and CV of 22%, this assay appears as a sensitive and reproducible system for evaluation of estrogenic activity. Moreover, estrogenic responses of 17 pure compounds corresponded well, qualitatively and quantitatively, with other in vitro and in vivo estrogenicity screens, such as the classical E-screen (R 2 = 0.98), the estrogen receptor (ER) binding (R 2 = 0.84) and the ER transcription activation assay (R 2 = 0.87). To evaluate the applicability of this assay for complex samples, influents and effluents of 10 STPs covering different treatment processes, were compared and ranked according to estrogenic removal efficiencies. Activated sludge treatment with phosphorus and nitrogen removal appeared most effective in eliminating estrogenic activity, followed by activated sludge, lagoon and filter bed. This is well in agreement with previous findings based on chemical analysis or biological activity screens. Moreover, ER blocking experiments indicated that cell proliferative responses were mainly ER mediated, illustrating that the complexity of the end point, cell proliferation, compared to other ER screens, does not hamper the interpretation of the results. Therefore, this study, among other E-screen studies, supports the use of

  5. Food Sample Preparation for the Determination of Sulfonamides by High-Performance Liquid Chromatography: State-of-the-Art

    Directory of Open Access Journals (Sweden)

    Dimitrios Bitas

    2018-06-01

    Full Text Available Antibiotics are a common practice in veterinary medicine, mainly for therapeutic purposes. Sectors of application include livestock farming, aquacultures, and bee-keeping, where bacterial infections are frequent and can be economically damaging. However, antibiotics are usually administered in sub-therapeutic doses as prophylactic and growth promoting agents. Due to their excessive use, antibiotic residues can be present in foods of animal origin, which include meat, fish, milk, eggs, and honey, posing health risks to consumers. For this reason, authorities have set maximum residue limits (MRLs of certain antibiotics in food matrices, while analytical methods for their determination have been developed. This work focuses on antibiotic extraction and determination, part of which was presented at the “1st Conference in Chemistry for Graduate, Postgraduate Students and PhD Candidates at the Aristotle University of Thessaloniki”. Taking a step further, this paper is a review of the most recent sample preparation protocols applied for the extraction of sulfonamide antibiotics from food samples and their determination with high-performance liquid chromatography (HPLC, covering a five-year period.

  6. Equilibrium Passive Sampling of POP in Lipid-Rich and Lean Fish Tissue: Quality Control Using Performance Reference Compounds.

    Science.gov (United States)

    Rusina, Tatsiana P; Carlsson, Pernilla; Vrana, Branislav; Smedes, Foppe

    2017-10-03

    Passive sampling is widely used to measure levels of contaminants in various environmental matrices, including fish tissue. Equilibrium passive sampling (EPS) of persistent organic pollutants (POP) in fish tissue has been hitherto limited to application in lipid-rich tissue. We tested several exposure methods to extend EPS applicability to lean tissue. Thin-film polydimethylsiloxane (PDMS) passive samplers were exposed statically to intact fillet and fish homogenate and dynamically by rolling with cut fillet cubes. The release of performance reference compounds (PRC) dosed to passive samplers prior to exposure was used to monitor the exchange process. The sampler-tissue exchange was isotropic, and PRC were shown to be good indicators of sampler-tissue equilibration status. The dynamic exposures demonstrated equilibrium attainment in less than 2 days for all three tested fish species, including lean fish containing 1% lipid. Lipid-based concentrations derived from EPS were in good agreement with lipid-normalized concentrations obtained using conventional solvent extraction. The developed in-tissue EPS method is robust and has potential for application in chemical monitoring of biota and bioaccumulation studies.

  7. Performance of two liquids scintillation and optimization of a Wallac 1411 counter in the tritium quantification in aqueous samples

    International Nuclear Information System (INIS)

    Contreras de la Cruz, E. de J.; Lopez del Rio, H.; Davila R, J. I.; Mireles G, F.; Pinedo V, J. L.

    2014-10-01

    The optimization of a liquid scintillation counting Wallac 1411 is presented as well as the performance of the liquids scintillation miscible in water OptiPhase Hi Safe 3 and Last Gold Ab, in the tritium quantification in aqueous samples. The luminescence effect, the quenching, the solution ph and the level of pulse amplitude comparator (Pac) were evaluated in the response of both liquids scintillation in the tritium measurement. The quenching and the luminescence modify the scintillators response; in the first of them the counting efficiency decreases and the minimum detectable activity increases; the second interferes in the tritium quantification in the interest window, but the effect disappears after 4 hours of darkness of the samples. The maximum counting efficiency was of 24% for OptiPhase Hi Safe 3 and 31% for Last Gold Ab, diminishing with the quenching until values of 8 and 11%, respectively. For a counting time of 6 hours and lower quenching, the minimum detectable concentration for OptiPhase Hi Safe 3 was of 13.4 ± 0.2 Bq/L and 9.9 ± 0.1 Bq/L for Last Gold Ab. Both scintillators responded appropriately to sour and basic solutions, being only presented chemiluminescence in Last Gold Ab to ph highly basic. The Pac application that varies between 1 and 256 does not have effect in the tritium measurement until values above 90. (Author)

  8. Observation of atomic arrangement by using photoelectron holography and atomic stereo-photograph

    International Nuclear Information System (INIS)

    Matsushita, Tomohiro; Guo, Fang Zhun; Agui, Akane; Matsui, Fumihiko; Daimon, Hiroshi

    2006-01-01

    Both a photoelectron holography and atomic stereo-photograph are the atomic structure analysis methods on the basis of photoelectron diffraction. They have six special features such as 1) direct determination of atomic structure, 2) measurement of three dimensional atomic arrangements surrounding of specific element in the sample, 3) determination of position of atom in spite of electron cloud, 4) unnecessary of perfect periodic structure, 5) good sensitivity of structure in the neighborhood of surface and 6) information of electron structure. Photoelectron diffraction, the principle and measurement system of photoelectron holography and atomic stereo-photograph is explained. As application examples of atomic stereo-photograph, the single crystal of cupper and graphite are indicated. For examples of photoelectron holography, Si(001)2p and Ge(001)3s are explained. (S.Y.)

  9. ECR plasma photographs as a plasma diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Racz, R; Biri, S; Palinkas, J [Institute of Nuclear Research (ATOMKI), H-4026 Debrecen, Bem ter 18/c (Hungary)

    2011-04-15

    Low, medium or highly charged ions delivered by electron cyclotron resonance (ECR) ion sources all are produced in the ECR plasma. In order to study such plasmas, high-resolution visible light plasma photographs were taken at the ATOMKI ECR ion source. An 8 megapixel digital camera was used to photograph plasmas made from He, methane, N, O, Ne, Ar, Kr, Xe gases and from their mixtures. The analysis of the photo series gave many qualitative and some valuable physical information on the nature of ECR plasmas. A comparison was made between the plasma photos and computer simulations, and conclusions were drawn regarding the cold electron component of the plasma. The warm electron component of similar simulation was compared with x-ray photos emitted by plasma ions. While the simulations are in good agreement with the photos, a significant difference was found between the spatial distribution of the cold and warm electrons.

  10. The Cambridge photographic atlas of galaxies

    CERN Document Server

    König, Michael

    2017-01-01

    Galaxies - the Milky Way's siblings - offer a surprising variety of forms and colours. Displaying symmetrical spiral arms, glowing red nebulae or diffuse halos, even the image of a galaxy can reveal much about its construction. All galaxies consist of gas, dust and stars, but the effects of gravity, dark matter and the interaction of star formation and stellar explosions all influence their appearances. This volume showcases more than 250 of the most beautiful galaxies within an amateur's reach and uses them to explain current astrophysical research. It features fantastic photographs, unique insights into our knowledge, tips on astrophotography and essential facts and figures based on the latest science. From the Andromeda Galaxy to galaxy clusters and gravitational lenses, the nature of galaxies is revealed through these stunning amateur photographs. This well illustrated reference atlas deserves a place on the bookshelves of astronomical imagers, observers and armchair enthusiasts.

  11. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters.

    Science.gov (United States)

    Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B

    2013-11-01

    Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and

  12. Investigation of Photographic Image Quality Estimators

    Science.gov (United States)

    1980-04-01

    Bibeman (1973) describes acutance as being "expressed in terms of the mean square of the gradient of . . . density (in a photographic image) with...the density difference AD. for each interval from the (smoothed) microdensitometer trace (calibrated in density units). 4. Compute the gradient -77...resolution." Rotacion Effects: The conditions were: Target: Shutter Speed: I- requency: Arplitude: Medium contrast, variable aspect 250 milliseconds

  13. Front Cover Photograph & Interview for FREEYE Magazine

    OpenAIRE

    Murray, Matthew

    2003-01-01

    Matthew Murray Front Cover Photograph & Interview for FREEYE Magazine - Dutch Quarterly For Exceptional International Photography, Holland.\\ud The article focuses on Murray's practice, his personal work, commissioned work, advertising, gallery and exhibition work along with his methodology. Looking at Murray's inspirations and how they feed into his personal projects and how this personal work feeds into shooting above the line advertising campaigns. Murray's work blurs the lines between pers...

  14. Perfection of the individual photographic emulsion dosimeter

    International Nuclear Information System (INIS)

    Soudain, G.

    1960-01-01

    A photographic dosimeter making possible the measurement of γ radiation doses of from 10 mr up to 800 r by means of 3 emulsion bands of varying sensitivity stuck to the same support is described. The dosimeter has also a zone for marking and a test film insensitive to radiation. This requires a photometric measurement by diffuse reflection an d makes it possible to measure doses with an accuracy of 20 per cent. (author) [fr

  15. Tracking Protests Using Geotagged Flickr Photographs.

    Directory of Open Access Journals (Sweden)

    Merve Alanyali

    Full Text Available Recent years have witnessed waves of protests sweeping across countries and continents, in some cases resulting in political and governmental change. Much media attention has been focused on the increasing usage of social media to coordinate and provide instantly available reports on these protests. Here, we investigate whether it is possible to identify protest outbreaks through quantitative analysis of activity on the photo sharing site Flickr. We analyse 25 million photos uploaded to Flickr in 2013 across 244 countries and regions, and determine for each week in each country and region what proportion of the photographs are tagged with the word "protest" in 34 different languages. We find that higher proportions of "protest"-tagged photographs in a given country and region in a given week correspond to greater numbers of reports of protests in that country and region and week in the newspaper The Guardian. Our findings underline the potential value of photographs uploaded to the Internet as a source of global, cheap and rapidly available measurements of human behaviour in the real world.

  16. The Impact of Simulated Nature on Patient Outcomes: A Study of Photographic Sky Compositions.

    Science.gov (United States)

    Pati, Debajyoti; Freier, Patricia; O'Boyle, Michael; Amor, Cherif; Valipoor, Shabboo

    2016-01-01

    To examine whether incorporation of simulated nature, in the form of ceiling mounted photographic sky compositions, influences patient outcomes. Previous studies have shown that most forms of nature exposure have a positive influence on patients. However, earlier studies have mostly focused on wall-hung nature representations. The emergence of simulated nature products has raised the question regarding the effects of the new product on patient outcomes. A between-subject experimental design was adopted, where outcomes from five inpatient rooms with sky composition ceiling fixture were compared to corresponding outcomes in five identical rooms without the intervention. Data were collected from a total of 181 subjects on 11 outcomes. Independent sample tests were performed to identify differences in mean outcomes. Significant positive outcomes were observed in environmental satisfaction and diastolic blood pressure (BP). Environmental satisfaction in the experimental group was 12.4% higher than the control group. Direction of association for diastolic BP, nausea/indigestion medication, acute stress, anxiety, pain, and environmental satisfaction were consistent with a priori hypothesis. A post hoc exploratory assessment involving patients who did not self-request additional pain and sleep medication demonstrated confirmatory directions for all outcomes except Systolic BP, and statistically significant outcomes for Acute Stress and Anxiety-Acute Stress and Anxiety levels of the experimental group subjects was 53.4% and 34.79% lower, respectively, than that of the control group subjects. Salutogenic benefits of photographic sky compositions render them better than traditional ceiling tiles and offer an alternative to other nature interventions. © The Author(s) 2015.

  17. Relationships Between Selected Teacher Behaviors and Pupil Academic Achievement: Preliminary Observations (Sample Project A). The Effect of Teacher Input on Student Performance (Sample Project B). Technical Report #35.

    Science.gov (United States)

    Au, Kathryn H.

    This Kamehameha Early Education Program (KEEP) report describes two studies on the effects of student-teacher interaction on student performance. Study I explored the relationship between three kinds of teacher behaviors (modeling, teacher attention to individual students, and praise-giving to individual students) and the pupil's academic…

  18. When representations conflict with reality: the preschooler's problem with false beliefs and "false" photographs.

    Science.gov (United States)

    Zaitchik, D

    1990-04-01

    It has been argued that young preschoolers cannot correctly attribute a false belief to a deceived actor (Wimmer & Perner, 1983). Some researchers claim that the problem lies in the child's inadequate epistemology (Chandler & Boyes, 1982; Wellman, 1988); as such, it is specific to the child's theory of mind and no such problem should appear in reasoning about nonmental representations. This prediction is tested below in the "false photograph" task: here an actor takes a photograph of an object in location X; the object is then moved to location Y. Preschool subjects are asked: "In the picture, where is the object?" Results indicate that photographs are no easier to reason about than are beliefs. Manipulations to boost performance on the photograph task proved ineffective. Further, an explanation of the failure as a processing limitation having nothing to do with the representational nature of beliefs or photographs was ruled out. It is argued that young children's failure on the false belief task is not due to an inadequate epistemology (though they may have one) and is symptomatic of a larger problem with representations.

  19. Reframing Photographic Research Methods in Human Geography: A Long-Term Reflection

    Science.gov (United States)

    Hall, Tim

    2015-01-01

    This paper offers a long-term reflection on the introduction of a photographic research project into a third-year undergraduate Human Geography module. The findings indicate that, whilst the students valued the project, it did impact on their overall performance, their evaluation of the module and the ways in which they spoke about it. The paper…

  20. Analysis of performance of a PCR-based assay to detect DNA of Aspergillus fumigatus in whole blood and serum: a comparative study with clinical samples.

    Science.gov (United States)

    Bernal-Martínez, Leticia; Gago, Sara; Buitrago, María J; Gomez-Lopez, Alicia; Rodríguez-Tudela, Juan L; Cuenca-Estrella, Manuel

    2011-10-01

    The performance of a real-time PCR-based assay was retrospectively analyzed (according to European Organization for Research and Treatment of Cancer/Mycosis Study Group criteria) in the samples of patients with invasive aspergillosis. A total of 711 serial samples (356 whole-blood and 355 serum samples) from 38 adult patients were analyzed. The Aspergillus fumigatus PCR assay results were positive for 89 of 356 (25%) whole-blood samples and 90 of 355 (25.35%) serum samples. Positive PCR results were seen in 29 of 31 (93.5%) patients for which serum was analyzed and in 31 of 33 (93.9%) cases with whole-blood specimens. Both blood and serum samples were available in 26 cases, and significant differences were not observed in this subgroup of cases. The average number of threshold cycles (C(T)) for positive blood samples was 37.6, and the average C(T) for serum was 37.4. The DNA concentration ranged between 2 and 50 fg per μl of sample, with average DNA concentrations of 10.2 and 11.7 fg in positive blood and serum samples, respectively (P > 0.01). The performance of this PCR-based quantitative assay was similar for both serum and blood samples. We recommend serum samples as the most convenient hematological sample to use for Aspergillus DNA quantification when serial determinations are done.

  1. Parametric study on the thermal performance of beam screen samples of the High-Luminosity LHC upgrade

    Science.gov (United States)

    Borges de Sousa, P.; Morrone, M.; Hovenga, N.; Garion, C.; van Weelderen, R.; Koettig, T.; Bremer, J.

    2017-12-01

    The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) will increase the accelerator’s luminosity by a factor 10 beyond its original design value, giving rise to more collisions and generating an intense flow of debris. A new beam screen has been designed for the inner triplets that incorporates tungsten alloy blocks to shield the superconducting magnets and the 1.9 K superfluid helium bath from incoming radiation. These screens will operate between 60 K and 80 K and are designed to sustain a nominal head load of 15 Wm-1, over 10 times the nominal heat load for the original LHC design. Their overall new and more complex design requires them and their constituent parts to be characterised from a thermal performance standpoint. In this paper we describe the experimental parametric study carried out on two principal thermal components: a representative sample of the beam screen with a tungsten-based alloy block and thermal link and the supporting structure composed of an assembly of ceramic spheres and titanium springs. Results from both studies are shown and discussed regarding their impact on the baseline considerations for the thermal design of the beam screens.

  2. The Relationship Between Cell Phone Use and Academic Performance in a Sample of U.S. College Students

    Directory of Open Access Journals (Sweden)

    Andrew Lepp

    2015-02-01

    Full Text Available The cell phone is ever-present on college campuses and is frequently used in settings where learning occurs. This study assessed the relationship between cell phone use and actual college grade point average (GPA after controlling for known predictors. As such, 536 undergraduate students from 82 self-reported majors at a large, public university were sampled. A hierarchical regression (R2 = .449 demonstrated that cell phone use was significantly (p < .001 and negatively (β = −.164 related to actual college GPA after controlling for demographic variables, self-efficacy for self-regulated learning, self-efficacy for academic achievement, and actual high school GPA, which were all significant predictors (p < .05. Thus, after controlling for other established predictors, increased cell phone use was associated with decreased academic performance. Although more research is needed to identify the underlying mechanisms, findings suggest a need to sensitize students and educators about the potential academic risks associated with high-frequency cell phone use.

  3. Performance comparison of machine learning methods for prognosis of hormone receptor status in breast cancer tissue samples.

    Science.gov (United States)

    Kalinli, Adem; Sarikoc, Fatih; Akgun, Hulya; Ozturk, Figen

    2013-06-01

    We examined the classification and prognostic scoring performances of several computer methods on different feature sets to obtain objective and reproducible analysis of estrogen receptor status in breast cancer tissue samples. Radial basis function network, k-nearest neighborhood search, support vector machines, naive bayes, functional trees, and k-means clustering algorithm were applied to the test datasets. Several features were employed and the classification accuracies of each method for these features were examined. The assessment results of the methods on test images were also experimentally compared with those of two experts. According to the results of our experimental work, a combination of functional trees and the naive bayes classifier gave the best prognostic scores indicating very good kappa agreement values (κ=0.899 and κ=0.949, p<0.001) with the experts. This combination also gave the best dichotomization rate (96.3%) for assessment of estrogen receptor status. Wavelet color features provided better classification accuracy than Laws texture energy and co-occurrence matrix features. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. iPad for digital photographers

    CERN Document Server

    Story, Derrick

    2013-01-01

    Discover innovative ways to strengthen your photography business with your iPad Many photographers are turning to the flexible, easy-to-use tools of the iPad and relying on them to wear a variety of hats in their photography business. Whether portable portfolio, editing tool, payment-tracking system, or appointment calendar, the iPad melds together the best attributes of the cell phone and a laptop computer and this unique book highlights them all. With this helpful resource, you'll learn how to get the most out of your iPad to not only improve your business but also enhance your p

  5. Adobe Photoshop CS5 for photographers

    CERN Document Server

    Evening, Martin

    2010-01-01

    With the new edition of this proven bestseller, Photoshop users can master the power of Photoshop CS5 with internationally renowned photographer and Photoshop hall-of-famer Martin Evening by their side.  In this acclaimed reference work, Martin covers everything from the core aspects of working in Photoshop to advanced techniques for professional results. Subjects covered include organizing a digital workflow, improving creativity, output, automating Photoshop, and using Camera RAW. The style of the book is extremely clear, with real examples, diagrams, illustrations, and step-by-step ex

  6. Adobe Photoshop Elements 11 for photographers

    CERN Document Server

    Andrews, Philip

    2013-01-01

    To coincide with some of the biggest changes in Photoshop Elements for years, Philip Andrews completely revises his bestselling title to include all the new features of this release. See how the new interface works alongside new tools, techniques and workflows to make editing, enhancing and sharing your pictures easier than ever. And as always, he introduces the changed and improved features with colorful illustrations and the clear step-by-step instruction that has made his books the go-to titles for photographers the world over. ????In this edition Andrews highlights followi

  7. The Effect of Subconscious Performance Goals on Academic Performance

    Science.gov (United States)

    Bipp, Tanja; Kleingeld, Ad; van Mierlo, Heleen; Kunde, Wilfried

    2017-01-01

    We investigated the impact of subconscious goals on academic performance in two field experiments. We show that unobtrusive priming of goals with regard to achievement motivation by means of a photograph improves performance in different educational contexts. High-school students who were exposed to an achievement-related photograph achieved…

  8. Critical assessment of the performance of electronic moisture analyzers for small amounts of environmental samples and biological reference materials.

    Science.gov (United States)

    Krachler, M

    2001-12-01

    Two electronic moisture analyzers were critically evaluated with regard to their suitability for determining moisture in small amounts (environmental matrices such as leaves, needles, soil, peat, sediments, and sewage sludge, as well as various biological reference materials. To this end, several homogeneous bulk materials were prepared which were subsequently employed for the development and optimization of all analytical procedures. The key features of the moisture analyzers included a halogen or ceramic heater and an integrated balance with a resolution of 0.1 mg, which is an essential prerequisite for obtaining precise results. Oven drying of the bulk materials in a conventional oven at 105 degrees C until constant mass served as reference method. A heating temperature of 65degrees C was found to provide accurate and precise results for almost all matrices investigated. To further improve the accuracy and precision, other critical parameters such as handling of sample pans, standby temperature, and measurement delay were optimized. Because of its ponderous heating behavior, the performance of the ceramic radiator was inferior to that of the halogen heater, which produced moisture results comparable to those obtained by oven drying. The developed drying procedures were successfully applied to the fast moisture analysis (1.4-6.3 min) of certified biological reference materials of similar provenance to the investigated the bulk materials. Moisture results for 200 mg aliquots ranged from 1.4 to 7.8% and good agreement was obtained between the recommended drying procedure for the reference materials and the electronic moisture analyzers with absolute uncertainties amounting to 0.1% and 0.2-0.3%, respectively.

  9. A photographic method to measure food item intake. Validation in geriatric institutions.

    Science.gov (United States)

    Pouyet, Virginie; Cuvelier, Gérard; Benattar, Linda; Giboreau, Agnès

    2015-01-01

    From both a clinical and research perspective, measuring food intake is an important issue in geriatric institutions. However, weighing food in this context can be complex, particularly when the items remaining on a plate (side dish, meat or fish and sauce) need to be weighed separately following consumption. A method based on photography that involves taking photographs after a meal to determine food intake consequently seems to be a good alternative. This method enables the storage of raw data so that unhurried analyses can be performed to distinguish the food items present in the images. Therefore, the aim of this paper was to validate a photographic method to measure food intake in terms of differentiating food item intake in the context of a geriatric institution. Sixty-six elderly residents took part in this study, which was performed in four French nursing homes. Four dishes of standardized portions were offered to the residents during 16 different lunchtimes. Three non-trained assessors then independently estimated both the total and specific food item intakes of the participants using images of their plates taken after the meal (photographic method) and a reference image of one plate taken before the meal. Total food intakes were also recorded by weighing the food. To test the reliability of the photographic method, agreements between different assessors and agreements among various estimates made by the same assessor were evaluated. To test the accuracy and specificity of this method, food intake estimates for the four dishes were compared with the food intakes determined using the weighed food method. To illustrate the added value of the photographic method, food consumption differences between the dishes were explained by investigating the intakes of specific food items. Although they were not specifically trained for this purpose, the results demonstrated that the assessor estimates agreed between assessors and among various estimates made by the same

  10. New applications of photographic materials in science and technique

    International Nuclear Information System (INIS)

    Buschmann, H.T.; Deml, R.; Duville, R.; Philippaerts, H.; Bollen, R.; Ranz, E.

    1976-01-01

    In spite of some disatvantages photographic materials based on silver halides possess the outstanding feature of high sensitivity. So again and again special photographic materials have been developed for new techniques including information storage. This contribution reports on some special photographic materials and it briefly discusses some applications. Materials are discussed in detail for holography, carrier-frequency photography, producing masks for integrated circuits, recording equidensities, bubble chamber photography, and for neutron-radiography. (orig.) [de

  11. Preserving and Archiving Astronomical Photographic Plates

    Science.gov (United States)

    Castelaz, M. W.; Cline, J. D.

    2005-05-01

    Astronomical objects change with time. New observations complement past observations recorded on photographic plates. Analyses of changes provide essential routes to information about an object's formation, constitution and evolution. Preserving a century of photographic plate observations is thus of paramount importance. Plate collections are presently widely dispersed; plates may be stored in poor conditions, and are effectively inaccessible to both researchers and historians. We describe a planned project at Pisgah Astronomical Research Institute to preserve the collections of astronomical plates in the United States by gathering them into a single storage location. Collections will be sorted, cleaned, and cataloged on-line so as to provide access to researchers. Full scientific and historic use of the material then requires the observations themselves to be accessible digitally. The project's goal will be the availability of these data as a unique, fully-maintained scientific and educational resource. The new archive will support trans-disciplinary research such as the chemistry of the Earth's atmosphere, library information science, trends in local weather patterns, and impacts of urbanization on telescope use, while the hand-written observatory logs will be a valuable resource for science historians and biographers.

  12. ASCII Art Synthesis from Natural Photographs.

    Science.gov (United States)

    Xu, Xuemiao; Zhong, Linyuan; Xie, Minshan; Liu, Xueting; Qin, Jing; Wong, Tien-Tsin

    2017-08-01

    While ASCII art is a worldwide popular art form, automatic generating structure-based ASCII art from natural photographs remains challenging. The major challenge lies on extracting the perception-sensitive structure from the natural photographs so that a more concise ASCII art reproduction can be produced based on the structure. However, due to excessive amount of texture in natural photos, extracting perception-sensitive structure is not easy, especially when the structure may be weak and within the texture region. Besides, to fit different target text resolutions, the amount of the extracted structure should also be controllable. To tackle these challenges, we introduce a visual perception mechanism of non-classical receptive field modulation (non-CRF modulation) from physiological findings to this ASCII art application, and propose a new model of non-CRF modulation which can better separate the weak structure from the crowded texture, and also better control the scale of texture suppression. Thanks to our non-CRF model, more sensible ASCII art reproduction can be obtained. In addition, to produce more visually appealing ASCII arts, we propose a novel optimization scheme to obtain the optimal placement of proportional-font characters. We apply our method on a rich variety of images, and visually appealing ASCII art can be obtained in all cases.

  13. Development of new methodology for dose calculation in photographic dosimetry

    International Nuclear Information System (INIS)

    Daltro, T.F.L.; Campos, L.L.; Perez, H.E.B.

    1996-01-01

    The personal dosemeter system of IPEN is based on film dosimetry. Personal doses at IPEN are mainly due to X or gamma radiation. The use of personal photographic dosemeters involves two steps: firstly, data acquisition including their evaluation with respect to the calibration quantity and secondly, the interpretation of the data in terms of effective dose. The effective dose was calculated using artificial intelligence techniques by means of neural network. The learning of the neural network was performed by taking the readings of optical density as a function of incident energy and exposure from the calibration curve. The obtained output in the daily grind is the mean effective energy and the effective dose. (author)

  14. Development of new methodology for dose calculation in photographic dosimetry

    International Nuclear Information System (INIS)

    Daltro, T.F.L.

    1994-01-01

    A new methodology for equivalent dose calculations has been developed at IPEN-CNEN/SP to be applied at the Photographic Dosimetry Laboratory using artificial intelligence techniques by means of neutral network. The research was orientated towards the optimization of the whole set of parameters involves in the film processing going from the irradiation in order to obtain the calibration curve up to the optical density readings. The learning of the neutral network was performed by taking the readings of optical density from calibration curve as input and the effective energy and equivalent dose as output. The obtained results in the intercomparison show an excellent agreement with the actual values of dose and energy given by the National Metrology Laboratory of Ionizing Radiation. (author)

  15. Development of new methodology for dose calculation in photographic dosimetry

    International Nuclear Information System (INIS)

    Daltro, T.F.L.; Campos, L.L.

    1994-01-01

    A new methodology for equivalent dose calculation has been developed at IPEN-CNEN/SP to be applied at the Photographic Dosimetry Laboratory using artificial intelligence techniques by means of neural network. The research was oriented towards the optimization of the whole set of parameters involved in the film processing going from the irradiation in order to obtain the calibration curve up to the optical density readings. The learning of the neural network was performed by taking readings of optical density from calibration curve as input and the effective energy and equivalent dose as output. The obtained results in the intercomparison show an excellent agreement with the actual values of dose and energy given by the National Metrology Laboratory of Ionizing Radiation

  16. Route Network Construction with Location-Direction-Enabled Photographs

    Science.gov (United States)

    Fujita, Hideyuki; Sagara, Shota; Ohmori, Tadashi; Shintani, Takahiko

    2018-05-01

    We propose a method for constructing a geometric graph for generating routes that summarize a geographical area and also have visual continuity by using a set of location-direction-enabled photographs. A location- direction-enabled photograph is a photograph that has information about the location (position of the camera at the time of shooting) and the direction (direction of the camera at the time of shooting). Each nodes of the graph corresponds to a location-direction-enabled photograph. The location of each node is the location of the corresponding photograph, and a route on the graph corresponds to a route in the geographic area and a sequence of photographs. The proposed graph is constructed to represent characteristic spots and paths linking the spots, and it is assumed to be a kind of a spatial summarization of the area with the photographs. Therefore, we call the routes on the graph as spatial summary route. Each route on the proposed graph also has a visual continuity, which means that we can understand the spatial relationship among the continuous photographs on the route such as moving forward, backward, turning right, etc. In this study, when the changes in the shooting position and shooting direction satisfied a given threshold, the route was defined to have visual continuity. By presenting the photographs in order along the generated route, information can be presented sequentially, while maintaining visual continuity to a great extent.

  17. Automated detection of fundus photographic red lesions in diabetic retinopathy.

    Science.gov (United States)

    Larsen, Michael; Godt, Jannik; Larsen, Nicolai; Lund-Andersen, Henrik; Sjølie, Anne Katrin; Agardh, Elisabet; Kalm, Helle; Grunkin, Michael; Owens, David R

    2003-02-01

    To compare a fundus image-analysis algorithm for automated detection of hemorrhages and microaneurysms with visual detection of retinopathy in patients with diabetes. Four hundred fundus photographs (35-mm color transparencies) were obtained in 200 eyes of 100 patients with diabetes who were randomly selected from the Welsh Community Diabetic Retinopathy Study. A gold standard reference was defined by classifying each patient as having or not having diabetic retinopathy based on overall visual grading of the digitized transparencies. A single-lesion visual grading was made independently, comprising meticulous outlining of all single lesions in all photographs and used to develop the automated red lesion detection system. A comparison of visual and automated single-lesion detection in replicating the overall visual grading was then performed. Automated red lesion detection demonstrated a specificity of 71.4% and a resulting sensitivity of 96.7% in detecting diabetic retinopathy when applied at a tentative threshold setting for use in diabetic retinopathy screening. The accuracy of 79% could be raised to 85% by adjustment of a single user-supplied parameter determining the balance between the screening priorities, for which a considerable range of options was demonstrated by the receiver-operating characteristic (area under the curve 90.3%). The agreement of automated lesion detection with overall visual grading (0.659) was comparable to the mean agreement of six ophthalmologists (0.648). Detection of diabetic retinopathy by automated detection of single fundus lesions can be achieved with a performance comparable to that of experienced ophthalmologists. The results warrant further investigation of automated fundus image analysis as a tool for diabetic retinopathy screening.

  18. Computer aided method for colour calibration and analysis of digital rock photographs

    Directory of Open Access Journals (Sweden)

    Matic Potočnik

    2015-12-01

    Full Text Available The methods used in geology to determine colour and colour coverage are expensive, time consuming, and/ or subjective. Estimates of colour coverage can only be approximate since they are based on rough comparisonbased measuring etalons and subjective estimation, which is dependent upon the skill and experience of the person performing the estimation. We present a method which accelerates, simplifis, and objectifis these tasks using a computer application. It automatically calibrates the colours of a digital photo, and enables the user to read colour values and coverage, even after returning from fild work. Colour identifiation is based on the Munsell colour system. For the purposes of colour calibration we use the X-Rite ColorChecker Passport colour chart placed onto the photographed scene. Our computer application detects the ColorChecker colour chart, and fids a colour space transformation to calibrate the colour in the photo. The user can then use the application to read colours within selected points or regions of the photo. The results of the computerised colour calibration were compared to the reference values of the ColorChecker chart. The values slightly deviate from the exact values, but the deviation is around the limit of human capability for visual comparison. We have devised an experiment, which compares the precision of the computerised colour analysis and manual colour analysis performed on a variety of rock samples with the help of geology students using Munsell Rock-color Chart. The analysis showed that the precision of manual comparative identifiation on multicoloured samples is somewhat problematic, since the choice of representative colours and observation points for a certain part of a sample are subjective. The computer based method has the edge in verifibility and repeatability of the analysis since the application the original photo to be saved with colour calibration, and tagging of colouranalysed points and regions.

  19. Comparison of the diagnostic performance of bacterial culture of nasopharyngeal swab and bronchoalveolar lavage fluid samples obtained from calves with bovine respiratory disease.

    Science.gov (United States)

    Capik, Sarah F; White, Brad J; Lubbers, Brian V; Apley, Michael D; DeDonder, Keith D; Larson, Robert L; Harhay, Greg P; Chitko-McKown, Carol G; Harhay, Dayna M; Kalbfleisch, Ted S; Schuller, Gennie; Clawson, Michael L

    2017-03-01

    OBJECTIVE To compare predictive values, extent of agreement, and gamithromycin susceptibility between bacterial culture results of nasopharyngeal swab (NPS) and bronchoalveolar lavage fluid (BALF) samples obtained from calves with bovine respiratory disease (BRD). ANIMALS 28 beef calves with clinical BRD. PROCEDURES Pooled bilateral NPS samples and BALF samples were obtained for bacterial culture from calves immediately before and at various times during the 5 days after gamithromycin (6 mg/kg, SC, once) administration. For each culture-positive sample, up to 12 Mannheimia haemolytica, 6 Pasteurella multocida, and 6 Histophilus somni colonies underwent gamithromycin susceptibility testing. Whole-genome sequencing was performed on all M haemolytica isolates. For paired NPS and BALF samples collected 5 days after gamithromycin administration, the positive and negative predictive values for culture results of NPS samples relative to those of BALF samples and the extent of agreement between the sampling methods were determined. RESULTS Positive and negative predictive values of NPS samples were 67% and 100% for M haemolytica, 75% and 100% for P multocida, and 100% and 96% for H somni. Extent of agreement between results for NPS and BALF samples was substantial for M haemolytica (κ, 0.71) and H somni (κ, 0.78) and almost perfect for P multocida (κ, 0.81). Gamithromycin susceptibility varied within the same sample and between paired NPS and BALF samples. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated culture results of NPS and BALF samples from calves with BRD should be interpreted cautiously considering disease prevalence within the population, sample collection relative to antimicrobial administration, and limitations of diagnostic testing methods.

  20. Liquid chromatography and ultra-performance liquid chromatography-mass spectrometry fingerprinting of human urine: sample stability under different handling and storage conditions for metabonomics studies.

    Science.gov (United States)

    Gika, Helen G; Theodoridis, Georgios A; Wilson, Ian D

    2008-05-02

    Typically following collection biological samples are kept in a freezer for periods ranging from a few days to several months before analysis. Experience has shown that in LC-MS-based metabonomics research the best analytical practice is to store samples as these are collected, complete the sample set and analyse it in a single run. However, this approach is prudent only if the samples stored in the refrigerator or in the freezer are stable. Another important issue is the stability of the samples following the freeze-thaw process. To investigate these matters urine samples were collected from 6 male volunteers and analysed by LC-MS and ultra-performance liquid chromatography (UPLC)-MS [in both positive and negative electrospray ionization (ESI)] on the day of collection or at intervals of up to 6 months storage at -20 degrees C and -80 degrees C. Other sets of these samples underwent a series of up to nine freeze-thaw cycles. The stability of samples kept at 4 degrees C in an autosampler for up to 6 days was also assessed, with clear differences appearing after 48h. Data was analysed using multivariate statistical analysis (principal component analysis). The results show that sample storage at both -20 and -80 degrees C appeared to ensure sample stability. Similarly up to nine freeze thaw cycles were without any apparent effect on the profile.

  1. Matching-to-sample performance is better analyzed in terms of a four-term contingency than in terms of a three-term contingency.

    Science.gov (United States)

    Jones, Brent M; Elliffe, Douglas M

    2013-07-01

    Four pigeons performed a simultaneous matching-to-sample (MTS) task involving two samples and two comparisons that differed in their pixel density and luminance. After a long history of reinforcers for correct responses after both samples, 15 conditions arranged either continuous reinforcement of correct responses after Sample 1 and extinction for all responses after Sample 2, or vice versa. The sample after which correct responses were reinforced alternated across successive conditions. The disparity between the samples and the disparity between the comparisons were varied independently across conditions in a quasifactorial design. Contrary to predictions of extant quantitative models, which assume that MTS tasks involve two 3-term contingencies of reinforcement, matching accuracies were not at chance levels in these conditions, comparison-selection ratios differed after the two samples, and effects on matching accuracies of both sample disparity and comparison disparity were observed. These results were, however, consistent with ordinal and sometimes quantitative predictions of Jones' (2003) theory of stimulus and reinforcement effects in MTS tasks. This theory asserts that MTS tasks involve four-term contingencies of reinforcement and that any tendency to select one comparison more often than the other over a set of trials reflects meaningful differences between comparison-discrimination accuracies after the two samples. © Society for the Experimental Analysis of Behavior.

  2. AHP 44: DPAL RGYAL: ARTIST AND PHOTOGRAPHER

    Directory of Open Access Journals (Sweden)

    Klu thar rgyal ཀླུ་ཐར་རྒྱལ།

    2017-02-01

    Full Text Available One sweltering summer afternoon in 2016, my family was enjoying yogurt while sitting in order of age around a table at my home. Father suddenly clapped his leg and blurted out "Oh! I remember!" took his cell phone from his coat pocket and said, "Klu kho, please translate these new Chinese messages for me." "China Mobile is really your best friend! It texts you almost every day!" I joked, taking the phone from his hand. One message was for my older brother, Dpal rgyal. The prefecture government informed Brother (b. 1980 that he was chosen to represent Mtsho lho (Hainan Tibetan Autonomous Prefecture for the 2016 Mtsho sngon (Qinghai Province Disabled Persons vocational skills competition in the photography category. Photography contestants were required to bring their own camera and would take photographs at the competition venue. ...

  3. Determination of drugs in biological fluids by high-performance liquid chromatography with on-line sample processing.

    Science.gov (United States)

    Oertel, R; Richter, K; Gramatté, T; Kirch, W

    1998-02-27

    An automated two column HPLC system with the new packing material LiChrospher RP-18 ADS (alkyl-diol-silica) was tested for the determination of several drugs and metabolites (talinolol, celiprolol, metoprolol, oxprenolol, triamterene, trimethoprim, tiracizine, articaine, detajmium, ajmaline, lamotrigine) in various biological fluids (serum, urine, intestinal aspirates, supernatants of cell cultures and supernatants after protein denaturation). The method allows the direct injection of biological fluids into a reversed-phase HPLC system and on-line clean-up and sample enrichment by a column-switching technique. Precision, accuracy and sensitivity were similar to conventional assays as described in the literature. With this new method it was possible to measure drug concentrations in various biological fluids without changing the sample preparation procedure. In some cases an additional sample preparation like protein denaturation or solid-phase extraction was advantageous to enhance the sensitivity of the method and the life-time of the ADS column.

  4. Molecularly imprinted membrane extraction combined with high-performance liquid chromatography for selective analysis of cloxacillin from shrimp samples.

    Science.gov (United States)

    Du, Wei; Sun, Min; Guo, Pengqi; Chang, Chun; Fu, Qiang

    2018-09-01

    Nowadays, the abuse of antibiotics in aquaculture has generated considerable problems for food safety. Therefore, it is imperative to develop a simple and selective method for monitoring illegal use of antibiotics in aquatic products. In this study, a method combined molecularly imprinted membranes (MIMs) extraction and liquid chromatography was developed for the selective analysis of cloxacillin from shrimp samples. The MIMs was synthesized by UV photopolymerization, and characterized by scanning electron microscope, Fourier transform infrared spectra, thermo-gravimetric analysis and swelling test. The results showed that the MIMs exhibited excellent permselectivity, high adsorption capacity and fast adsorption rate for cloxacillin. Finally, the method was utilized to determine cloxacillin from shrimp samples, with good accuracies and acceptable relative standard deviation values for precision. The proposed method was a promising alternative for selective analysis of cloxacillin in shrimp samples, due to the easy-operation and excellent selectivity. Copyright © 2018. Published by Elsevier Ltd.

  5. Photographic assessment of burn size and depth: reliability and validity

    NARCIS (Netherlands)

    Hop, M.; Moues, C.; Bogomolova, K.; Nieuwenhuis, M.; Oen, I.; Middelkoop, E.; Breederveld, R.; de Baar, M.

    2014-01-01

    Objective: The aim of this study was to examine the reliability and validity of using photographs of burns to assess both burn size and depth. Method: Fifty randomly selected photographs taken on day 0-1 post burn were assessed by seven burn experts and eight referring physicians. Inter-rater

  6. Using Photographs and Diagrams to Test Young Children's Mass Thinking

    Science.gov (United States)

    Cheeseman, Jill; McDonough, Andrea

    2013-01-01

    This paper reports the results of a pencil-and-paper test developed to assess young children's understanding of mass measurement. The innovative element of the test was its use of photographs. We found many children of the 295 6-8 year-old children tested could "read" the photographs and diagrams and recognise the images as…

  7. The Preservation and Care of Photographic Records in Heritage ...

    African Journals Online (AJOL)

    It is not unusual for libraries and heritage institutions to include photographic records and collections in their archival holdings. The short history of photography reveals that a range of different materials, chemicals and processes are involved in capturing photographic records, indicating the chemical complexity of the ...

  8. Photographs and Classroom Response Systems in Middle School Astronomy Classes

    Science.gov (United States)

    Lee, Hyunju; Feldman, Allan

    2015-01-01

    In spite of being readily available, photographs have played a minor and passive role in science classes. In our study, we present an active way of using photographs in classroom discussions with the use of a classroom response system (CRS) in middle school astronomy classes to teach the concepts of day-night and seasonal change. In this new…

  9. Evaluation of Genotoxic Effect of Photographic Effluent Using Allium ...

    African Journals Online (AJOL)

    The increased need to keep graphic records of events has led to the use of photography in investigation and surveys and hence increased photographic activities. Toxicological survey of photographic effluents has received little attention in Nigeria, though the constituents have been shown to be very toxic. This study ...

  10. Re-Presenting Self: Reading Some Van Kalker Studio Photographs ...

    African Journals Online (AJOL)

    The photographic implement, from the earliest days of its invention in Europe, in 1839, has been used to document events considered as real. However, notions of 'reality' could be ambiguous as objects or sceneries intended to be photographed are sometimes constructed to represent an imagined stereotypical reality.

  11. Camera aboard 'Friendship 7' photographs John Glenn during spaceflight

    Science.gov (United States)

    1962-01-01

    A camera aboard the 'Friendship 7' Mercury spacecraft photographs Astronaut John H. Glenn Jr. during the Mercury-Atlas 6 spaceflight (00302-3); Photographs Glenn as he uses a photometer to view the sun during sunsent on the MA-6 space flight (00304).

  12. The Estimated Impact of Performing Arts on Adolescent Mood within a Community Sample of Mental Health Professionals

    Science.gov (United States)

    King, Alan; Grieves, Julie; Opp, Dean

    2007-01-01

    In a brief survey, the authors solicited professional opinions regarding the probable impact of performing arts on adolescent mood stability using a hypothetical scenario where 20 moderately depressed 15-year-olds agreed to participate in a high school play, musical, or other singing performance. The results of the survey indicated that clinicians…

  13. Assessing the performance of multiplexed tandem PCR for the diagnosis of pathogenic genotypes of Theileria orientalis using pooled blood samples from cattle.

    Science.gov (United States)

    Gebrekidan, Hagos; Gasser, Robin B; Stevenson, Mark A; McGrath, Sean; Jabbar, Abdul

    2017-02-01

    Oriental theileriosis caused by multiple genotypes of Theileria orientalis is an important tick-borne disease of bovines. Here, we assessed the performance of an established multiplexed tandem PCR (MT-PCR) for the diagnosis of the two recognized, pathogenic genotypes (chitose and ikeda) of T. orientalis in cattle using pooled blood samples. We used a total of 265 cattle blood samples, which were divided into two groups according to previous MT-PCR results for individual samples. Samples in group 1 (n = 155) were from a herd with a relatively high prevalence of T. orientalis infection; and those in group 2 (n = 110) were from four herds with a low prevalence. For group 1, 31 and 15 batches of five- and ten-pooled samples (selected at random), respectively, were formed. For group 2, 22 and 11 batches of five- and ten-pooled samples (selected at random), respectively, were formed. DNAs from individual pooled samples in each batch and group were then tested by MT-PCR. For group 1, the apparent prevalences estimated using the 31 batches of five-pooled samples (97%) and 15 batches of ten-pooled samples (100%) were significantly higher compared with individual samples (75%). For group 2, higher apparent prevalences (9% and 36%) were also recorded for the 22 and 11 batches of pooled samples, respectively, compared with individual samples (7%). Overall, the average infection intensity recorded for the genotypes of chitose and ikeda were considerably lower in pooled compared with individual samples. The diagnostic specificities of MT-PCR were estimated at 95% and 94%, respectively, when batches of five- and ten-pooled samples were tested, and 94% for individual samples. The diagnostic sensitivity of this assay was estimated at 98% same for all individual, five- and ten-pooled samples. This study shows that screening batches of five- and ten-pooled blood samples from cattle herds are similar to those obtained for individual samples, and, importantly, that the reduced cost

  14. Effects of ozone on the various digital print technologies: Photographs and documents

    Energy Technology Data Exchange (ETDEWEB)

    Burge, D; Gordeladze, N; Bigourdan, J-L; Nishimura, D, E-mail: dmbpph@rit.ed [Image Permanence Institute at Rochester Institute of Technology, 70 Lomb Memorial Drive, Rochester, NY 14623 (United States)

    2010-06-01

    The harmful effects of ozone on inkjet photographs have been well documented. This project expands on that research by performing ozone tests on a greater variety of digital prints including colour electrophotographic and dye sublimation. The sensitivities of these materials are compared to traditionally printed materials (black-and-white electrophotographic, colour photographic and offset lithographic) to determine if the digital prints require special care practices. In general, the digital prints were more sensitive to ozone than traditional prints. Dye inkjet prints were more sensitive to fade than pigment inkjet, though pigment was not immune. The dye sublimation, colour electrophotographic (dry and liquid toner), and traditional print systems were relatively resistant to ozone. Text-based documents were evaluated in addition to photographic images, since little work has been done to determine if the type of object (image or text) has an impact on its sensitivity to ozone. The results showed that documents can be more resistant to ozone than photographs even when created using the same printer and inks. It is recommended that cultural heritage institutions not expose their porous-coated, dye-based inkjet photos to open air for extended periods of time. Other inkjet prints should be monitored for early signs of change.

  15. Effects of ozone on the various digital print technologies: Photographs and documents

    International Nuclear Information System (INIS)

    Burge, D; Gordeladze, N; Bigourdan, J-L; Nishimura, D

    2010-01-01

    The harmful effects of ozone on inkjet photographs have been well documented. This project expands on that research by performing ozone tests on a greater variety of digital prints including colour electrophotographic and dye sublimation. The sensitivities of these materials are compared to traditionally printed materials (black-and-white electrophotographic, colour photographic and offset lithographic) to determine if the digital prints require special care practices. In general, the digital prints were more sensitive to ozone than traditional prints. Dye inkjet prints were more sensitive to fade than pigment inkjet, though pigment was not immune. The dye sublimation, colour electrophotographic (dry and liquid toner), and traditional print systems were relatively resistant to ozone. Text-based documents were evaluated in addition to photographic images, since little work has been done to determine if the type of object (image or text) has an impact on its sensitivity to ozone. The results showed that documents can be more resistant to ozone than photographs even when created using the same printer and inks. It is recommended that cultural heritage institutions not expose their porous-coated, dye-based inkjet photos to open air for extended periods of time. Other inkjet prints should be monitored for early signs of change.

  16. In-camera automation of photographic composition rules.

    Science.gov (United States)

    Banerjee, Serene; Evans, Brian L

    2007-07-01

    At the time of image acquisition, professional photographers apply many rules of thumb to improve the composition of their photographs. This paper develops a joint optical-digital processing framework for automating composition rules during image acquisition for photographs with one main subject. Within the framework, we automate three photographic composition rules: repositioning the main subject, making the main subject more prominent, and making objects that merge with the main subject less prominent. The idea is to provide to the user alternate pictures obtained by applying photographic composition rules in addition to the original picture taken by the user. The proposed algorithms do not depend on prior knowledge of the indoor/outdoor setting or scene content. The proposed algorithms are also designed to be amenable to software implementation on fixed-point programmable digital signal processors available in digital still cameras.

  17. Actual distribution of Cronobacter spp. in industrial batches of powdered infant formula and consequences for performance of sampling strategies

    NARCIS (Netherlands)

    Jongenburger, I.; Reij, M.W.; Boer, E.P.J.; Gorris, L.G.M.; Zwietering, M.H.

    2011-01-01

    The actual spatial distribution of microorganisms within a batch of food influences the results of sampling for microbiological testing when this distribution is non-homogeneous. In the case of pathogens being non-homogeneously distributed, it markedly influences public health risk. This study

  18. The influence of uncertainties of measurements in laboratory performance evaluation using an intercomparison program of radionuclide assays in environmental samples

    International Nuclear Information System (INIS)

    Tauhata, Luiz; Elizabeth Couto Machado Vianna, Maria; Eduardo de Oliveira, Antonio; Cristina de Melo Ferreira, Ana; Julia Camara da Silva Braganca, Maura; Faria Clain, Almir

    2006-01-01

    To show the influence of measurement uncertainties in performance evaluation of laboratories, data from 42 comparison runs were evaluated using two statistical criteria. The normalized standard deviation, D, used by US EPA, that mainly takes into account the accuracy, and the normalized deviation, E, that includes the individual laboratory uncertainty used for performance evaluation in the key-comparisons by BIPM. The results show that data evaluated by the different criteria give a significant deviation of laboratory performance in each radionuclide assay when we analyse a large quantity of data

  19. A Comparison of Measures of Abnormal Performance on a Sample of Monthly Mutual Fund Returns, formerly titled; The Evaluation of Mutual Fund Performance: An Analysis of Monthly Returns

    OpenAIRE

    Grinblatt, Mark

    1989-01-01

    This paper empirically examines the Jensen Measure, the Positive Period Weighting Measure, developed in Grinblatt and Titman (1987a), measures developed from the Treynor-Mazuy (1966) quadratic regression on a sample 179 mutual funds, using a variety of benchmark portfolios. We find that the measures generally yield similar inferences when using the same benchmark and that inferences can vary, even from the same measure, when using different benchmarks. Several benchmarks, developed here, appe...

  20. Determine Conjugate Points of an Aerial Photograph Stereopairs using Seperate Channel Mean Value Technique

    Directory of Open Access Journals (Sweden)

    Andri Hernandi

    2009-11-01

    Full Text Available In the development of digital photogrammetric system, automatic image matching process play an important role. The automatic image matching is used in finding the conjugate points of an aerial photograph stereopair automatically. This matching technique gives quite significant contribution especially in the development of 3D photogrammetry in an attempt to get the exact and precise topographic information during the stereo restitution. There are two image matching methods that have been so far developed, i.e. the area based system for gray level environment and the feature based system for natural feature environment. This re¬search is trying to implement the area based matching with normalized cross correlation technique to get the correlation coefficient between the spectral value of the left image and its pair on the right. Based on the previous researches, the use of color image could increase the quality of match-ing. One of the color image matching technique is known as Separate Channel Mean Value. In order to be able to see the performance of the technique, a number of sampling areas with various different characteristics have been chosen, i.e. the heterogeneous, homogeneous, texture, shadow, and contrast. The result shows the highest similarity measure is obtained on heterogeneous sample area at size of all reference and search image, i.e. (11 pixels x 11 pixels and (23 pixels x 23 pixels. In these area the correlation coefficient reached more than 0.7 and the highest percentage of similarity measure is obtained. The average of total similarity measure of conjugate images in the sampling image area only reach about 41.43 % of success. Therefore, this technique has a weakness and some treatment to overcome the problems is still needed.

  1. Hybrid Capture 2 and cobas human papillomavirus assays perform similarly on SurePath samples from women with abnormalities

    DEFF Research Database (Denmark)

    Fornari, D; Rebolj, M; Bjerregaard, B

    2016-01-01

    OBJECTIVE: In two laboratories (Departments of Pathology, Copenhagen University Hospitals of Herlev and Hvidovre), we compared cobas and Hybrid Capture 2 (HC2) human papillomavirus (HPV) assays using SurePath® samples from women with atypical squamous cells of undetermined significance (ASCUS......) at ≥30 years and women after treatment of cervical intraepithelial neoplasia (CIN). METHODS: Samples from 566 women with ASCUS and 411 women after treatment were routinely tested with HC2 and, thereafter, with cobas. Histological outcomes were retrieved from the Danish Pathology Data Base. We calculated...... the overall agreement between the assays, and compared their sensitivity and specificity for ≥CIN2. RESULTS: In women with ASCUS, HC2 and cobas testing results were similar in the two laboratories. The overall agreement was 91% (95% CI, 88-93). After CIN treatment, the overall agreement was 87% (95% CI, 82...

  2. Lot quality assurance sampling to monitor supplemental immunization activity quality: an essential tool for improving performance in polio endemic countries.

    Science.gov (United States)

    Brown, Alexandra E; Okayasu, Hiromasa; Nzioki, Michael M; Wadood, Mufti Z; Chabot-Couture, Guillaume; Quddus, Arshad; Walker, George; Sutter, Roland W

    2014-11-01

    Monitoring the quality of supplementary immunization activities (SIAs) is a key tool for polio eradication. Regular monitoring data, however, are often unreliable, showing high coverage levels in virtually all areas, including those with ongoing virus circulation. To address this challenge, lot quality assurance sampling (LQAS) was introduced in 2009 as an additional tool to monitor SIA quality. Now used in 8 countries, LQAS provides a number of programmatic benefits: identifying areas of weak coverage quality with statistical reliability, differentiating areas of varying coverage with greater precision, and allowing for trend analysis of campaign quality. LQAS also accommodates changes to survey format, interpretation thresholds, evaluations of sample size, and data collection through mobile phones to improve timeliness of reporting and allow for visualization of campaign quality. LQAS becomes increasingly important to address remaining gaps in SIA quality and help focus resources on high-risk areas to prevent the continued transmission of wild poliovirus. © Crown copyright 2014.

  3. MALDI MS peptide mapping performance by in-gel digestion on a probe with prestructured sample supports

    DEFF Research Database (Denmark)

    Klenø, Tina Guldberg; Andreasen, Christian Maaløv; Kjeldal, Helle Ørsted

    2004-01-01

    Matrix-assisted laser desorption/ionization (tandem) mass spectrometry (MALDI MS) is widely used in protein chemistry and proteomics research for the identification and characterization of proteins isolated by polyacrylamide gel electrophoresis. In an effort to minimize sample handling and increa......-probe digestion protocol combined with MALDI tandem mass spectrometry provides a robust platform for proteomics research, including protein identification and determination of posttranslational modifications....

  4. Synthesis, characterization and nitrite ion sensing performance of reclaimable composite samples through a core-shell structure

    Science.gov (United States)

    Cui, Xiao; Yuqing, Zhao; Cui, Jiantao; Zheng, Qian; Bo, Wang

    2018-02-01

    The following paper reported and discussed a nitrite ion optical sensing platform based on a core-shell structure, using superamagnetic nanoparticles as the core, a silica molecular sieve MCM-41 as the shell and two rhodamine derivatives as probe, respectively. This superamagnetic core made this sensing platform reclaimable after finishing nitrite ion sensing procedure. This sensing platform was carefully characterized by means of electron microscopy images, porous structure analysis, magnetic response, IR spectra and thermal stability analysis. Detailed analysis suggested that the emission of these composite samples was quenchable by nitrite ion, showing emission turn off effect. A static sensing mechanism based on an additive reaction between chemosensors and nitrite ion was proposed. These composite samples followed Demas quenching equation against different nitrite ion concentrations. Limit of detection value was obtained as low as 0.4 μM. It was found that, after being quenched by nitrite ion, these composite samples could be reclaimed and recovered by sulphamic acid, confirming their recyclability.

  5. Preservation of photographic and cinematographic films by gamma radiation: Preliminary analyses

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, Maria Luiza E.; Santos, Paulo S.; Otubo, Larissa; Oliveira, Maria José A.; Vasquez, Pablo A.S., E-mail: malunagai@usp.br, E-mail: pavsalva@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    Brazilian weather conditions affect directly tangible materials causing deterioration notably getting worse by insects and fungi attack. In this sense, gamma radiation provided from the cobalt-60 is an excellent alternative tool to the traditional preservation process mainly because it has biocidal action. Radiation processing using gamma radiation for cultural heritage materials for disinfection has been widely used around the world in the last decades. Many cultural heritage objects especially made on paper and wood were studied in scientific publications aiming mechanical, physical and chemical properties changes. Over the last fifteen years, the Multipurpose Gamma Irradiation Facility of the Nuclear and Energy Research Institute located inside the Sao Paulo University campus has been irradiated many collections of archived materials, books, paintings and furniture. Adequate storage of photographic and cinematographic materials is a challenge for conservators from preservation institutions. Contamination by fungi is one of leading causes of problem in photographic and cinematographic collections. Several Sao Paulo University libraries have been affected by fungi in their photographic and cinematographic collections making it impossible to research on these materials either manipulate them for health and safety reasons. In this work are presented preliminary results of effects of the ionizing radiation in photographic and cinematographic films. Selected film samples made on cellulose acetate were prepared and characterized by FTIR-ATR spectroscopy. Samples were irradiated by gamma rays with absorbed dose between 2 kGy and 50 kGy. Irradiated samples were analyzed by UV-VIS spectroscopy and electron microscopy techniques. Results shown that disinfection by gamma radiation can be achieved safely applying the disinfection dose between 6 kGy to 15 kGy with no significant change or modification of main properties of the constitutive materials. (author)

  6. Preservation of photographic and cinematographic films by gamma radiation: Preliminary analyses

    International Nuclear Information System (INIS)

    Nagai, Maria Luiza E.; Santos, Paulo S.; Otubo, Larissa; Oliveira, Maria José A.; Vasquez, Pablo A.S.

    2017-01-01

    Brazilian weather conditions affect directly tangible materials causing deterioration notably getting worse by insects and fungi attack. In this sense, gamma radiation provided from the cobalt-60 is an excellent alternative tool to the traditional preservation process mainly because it has biocidal action. Radiation processing using gamma radiation for cultural heritage materials for disinfection has been widely used around the world in the last decades. Many cultural heritage objects especially made on paper and wood were studied in scientific publications aiming mechanical, physical and chemical properties changes. Over the last fifteen years, the Multipurpose Gamma Irradiation Facility of the Nuclear and Energy Research Institute located inside the Sao Paulo University campus has been irradiated many collections of archived materials, books, paintings and furniture. Adequate storage of photographic and cinematographic materials is a challenge for conservators from preservation institutions. Contamination by fungi is one of leading causes of problem in photographic and cinematographic collections. Several Sao Paulo University libraries have been affected by fungi in their photographic and cinematographic collections making it impossible to research on these materials either manipulate them for health and safety reasons. In this work are presented preliminary results of effects of the ionizing radiation in photographic and cinematographic films. Selected film samples made on cellulose acetate were prepared and characterized by FTIR-ATR spectroscopy. Samples were irradiated by gamma rays with absorbed dose between 2 kGy and 50 kGy. Irradiated samples were analyzed by UV-VIS spectroscopy and electron microscopy techniques. Results shown that disinfection by gamma radiation can be achieved safely applying the disinfection dose between 6 kGy to 15 kGy with no significant change or modification of main properties of the constitutive materials. (author)

  7. High performance liquid chromatography for simultaneous determination of xipamide, triamterene and hydrochlorothiazide in bulk drug samples and dosage forms.

    Science.gov (United States)

    Abd El-Hay, Soad S; Hashem, Hisham; Gouda, Ayman A

    2016-03-01

    A novel, simple and robust high-performance liquid chromatography (HPLC) method was developed and validated for simultaneous determination of xipamide (XIP), triamterene (TRI) and hydrochlorothiazide (HCT) in their bulk powders and dosage forms. Chromatographic separation was carried out in less than two minutes. The separation was performed on a RP C-18 stationary phase with an isocratic elution system consisting of 0.03 mol L(-1) orthophosphoric acid (pH 2.3) and acetonitrile (ACN) as the mobile phase in the ratio of 50:50, at 2.0 mL min(-1) flow rate at room temperature. Detection was performed at 220 nm. Validation was performed concerning system suitability, limits of detection and quantitation, accuracy, precision, linearity and robustness. Calibration curves were rectilinear over the range of 0.195-100 μg mL(-1) for all the drugs studied. Recovery values were 99.9, 99.6 and 99.0 % for XIP, TRI and HCT, respectively. The method was applied to simultaneous determination of the studied analytes in their pharmaceutical dosage forms.

  8. Performances on Symbol Digit Modalities Test, Color Trails Test, and modified Stroop test in a healthy, elderly Danish sample

    DEFF Research Database (Denmark)

    Vogel, Asmus; Stokholm, Jette; Jørgensen, Kasper

    2013-01-01

    This study presents Danish data for the Symbol Digit Modalities Test (SDMT), Color Trails Test (CTT), and a modified Stroop test from 100 subjects aged 60-87 years. Among the included demographic variables, age had the highest impact on test performances. Thus, the study presents separate data...

  9. Diagnostic performance of Schistosoma real-time PCR in urine samples from Kenyan children infected with Schistosoma haematobium

    DEFF Research Database (Denmark)

    Vinkeles Melchers, Natalie V. S.; van Dam, Govert J.; Shaproski, David

    2014-01-01

    treatment. METHODOLOGY: Previously collected urine samples (N = 390) from 114 preselected proven parasitological and/or clinical S. haematobium positive Kenyan schoolchildren were analyzed by a Schistosoma internal transcribed spacer-based real-time PCR after 14 years of storage. Pre-treatment day......, respectively. Based on the 'gold standard', PCR showed high sensitivity (>92%) as compared to >31% sensitivity for microscopy, both pre- and post-treatment. CONCLUSIONS/SIGNIFICANCE: Detection and quantification of Schistosoma DNA in urine by real-time PCR was shown to be a powerful and specific diagnostic...

  10. Ibuprofen analysis in blood samples by palladium particles-impregnated sodium montmorillonite electrodes: Validation using high performance liquid chromatography.

    Science.gov (United States)

    Loudiki, A; Boumya, W; Hammani, H; Nasrellah, H; El Bouabi, Y; Zeroual, M; Farahi, A; Lahrich, S; Hnini, K; Achak, M; Bakasse, M; El Mhammedi, M A

    2016-12-01

    The electrochemical detection of ibuprofen has been studied on Palladium-Montmorillonite (Mt) modified carbon paste electrode using differential pulse voltammetry. The optimization of the modifier preparation and the instrumental parameters was investigated. The results indicate that ibuprofen oxidation was favored in the presence of Pd-PdO particles. The quantitative determination of ibuprofen was statistically analyzed and validated using HPLC method. The detection and quantification limits, specificity and precision were found to be acceptable. Finally, the developed method was successfully applied for ibuprofen determination in human blood samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Diagnostic performance of an indirect enzyme-linked immunosorbent assay (ELISA) to detect bovine leukemia virus antibodies in bulk-tank milk samples

    Science.gov (United States)

    Nekouei, Omid; Durocher, Jean; Keefe, Greg

    2016-01-01

    This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs. PMID:27429469

  12. Classification of cultivation locations of Panax quinquefolius L samples using high performance liquid chromatography-electrospray ionization mass spectrometry and chemometric analysis

    Science.gov (United States)

    Panax quinquefolius L (P. quinquefolius L) samples grown in the United States and China were analyzed with high performance liquid chromatography-mass spectrometry (HPLC—MS). Prior to classification, the two-way datasets were subjected to pretreatment including baseline correction and retention tim...

  13. Validation of a high performance liquid chromatography analysis for the determination of noradrenaline and adrenaline in human urine with an on-line sample purification

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Kristiansen, J; Nielsen, J L

    1999-01-01

    A high performance liquid chromatography (HPLC) method with fluorescence detection including an on-line purification was established for determination of catecholamines in human urine. The method was evaluated using samples of pooled urine spiked with catecholamines and validated for measurements...

  14. Experiences performed at the C:R: Saluggia of ENEA in low-level determination of plutonium in biological and environmental samples

    International Nuclear Information System (INIS)

    Spezzano, Pasquale

    1997-10-01

    This report describes some experiences performed at the Research Center Saluggia of ENEA concerning low-level determination of plutonium in biological and environmental samples, with discussions of practical analytical problems. The main characteristics and properties of plutonium with emphasis to aqueous solutions chemistry and environmental behaviour are also reported

  15. Correlations between cephalometric and photographic measurements of facial attractiveness in Chinese and US patients after orthodontic treatment.

    Science.gov (United States)

    Oh, Hee Soo; Korn, Edward L; Zhang, Xiaoyun; Liu, Yan; Xu, Tianmin; Boyd, Robert; Baumrind, Sheldon

    2009-12-01

    Orthodontists rely on esthetic judgments from facial photographs. Concordance between estimates of facial attractiveness made from lateral cephalograms and those made from clinical photographs has not been determined. We conducted a preliminary examination to correlate clinicians' rankings of facial attractiveness from standardized end-of-treatment facial photographs (Photo Attractiveness Rank) with cephalometric measurements of facial attractiveness made for the same subjects at the same time. Forty-five Chinese and US orthodontic clinicians ranked end-of-treatment photographs of separate samples of 45 US and 48 Chinese adolescent patients for facial attractiveness. Separately for each sample, the photographic rankings were correlated with the values of 21 conventional hard- and soft-tissue measures from lateral cephalograms taken at the same visits as the photographs. Among US patients, higher rank for facial attractiveness on the photographs was strongly associated with higher values for profile angle, chin prominence, lower lip prominence, and Z-angle, and also with lower values for angle of convexity, H-angle, and ANB. Among Chinese patients, higher rank for facial attractiveness on the photographs was strongly associated with higher values for Z-angle and chin prominence, and also with lower values for angle of convexity, H-angle, B-line to upper lip, and mandibular plane angle. Chinese patients whose %lower face height values approximated the ethnic "ideal" (54%) tended to rank higher for facial attractiveness than patients with either higher or lower values for %lower face height. The absolute values of the correlations for the 7 US measures noted above ranged from 0.41 to 0.59; those of the 7 Chinese measures ranged from 0.39 to 0.49.The P value of the least statistically significant of these 14 correlations was 0.006, unadjusted for multiple comparisons. On the other hand, many cephalometric measures believed by clinicians to be indicators of facial

  16. SU-E-I-46: Sample-Size Dependence of Model Observers for Estimating Low-Contrast Detection Performance From CT Images

    International Nuclear Information System (INIS)

    Reiser, I; Lu, Z

    2014-01-01

    Purpose: Recently, task-based assessment of diagnostic CT systems has attracted much attention. Detection task performance can be estimated using human observers, or mathematical observer models. While most models are well established, considerable bias can be introduced when performance is estimated from a limited number of image samples. Thus, the purpose of this work was to assess the effect of sample size on bias and uncertainty of two channelized Hotelling observers and a template-matching observer. Methods: The image data used for this study consisted of 100 signal-present and 100 signal-absent regions-of-interest, which were extracted from CT slices. The experimental conditions included two signal sizes and five different x-ray beam current settings (mAs). Human observer performance for these images was determined in 2-alternative forced choice experiments. These data were provided by the Mayo clinic in Rochester, MN. Detection performance was estimated from three observer models, including channelized Hotelling observers (CHO) with Gabor or Laguerre-Gauss (LG) channels, and a template-matching observer (TM). Different sample sizes were generated by randomly selecting a subset of image pairs, (N=20,40,60,80). Observer performance was quantified as proportion of correct responses (PC). Bias was quantified as the relative difference of PC for 20 and 80 image pairs. Results: For n=100, all observer models predicted human performance across mAs and signal sizes. Bias was 23% for CHO (Gabor), 7% for CHO (LG), and 3% for TM. The relative standard deviation, σ(PC)/PC at N=20 was highest for the TM observer (11%) and lowest for the CHO (Gabor) observer (5%). Conclusion: In order to make image quality assessment feasible in the clinical practice, a statistically efficient observer model, that can predict performance from few samples, is needed. Our results identified two observer models that may be suited for this task

  17. Children's aesthetic understanding of photographic art and the quality of art-related parent-child interactions.

    Science.gov (United States)

    Szechter, Lisa E; Liben, Lynn S

    2007-01-01

    This research was designed to examine the quality of children's aesthetic understanding of photographs, observe social interactions between parents and children in this aesthetic domain, and study whether qualitatively different dyadic interactions were associated with children's own aesthetic understanding. Parents and children (7-13 years; 40 dyads) individually completed measures of aesthetic understanding and jointly selected photographs for a souvenir scrapbook. Parents' artistic experience varied widely and was associated with their own performance on aesthetic understanding measures. Children's performance on the individual aesthetic tasks was related to age, but not to parents' art experience nor to the qualities of parent-child discussions of aesthetic concepts. Among both parents and children, artistic experience was associated with aesthetic preferences for photographs.

  18. Development and validation of reversed-phase high performance liquid chromatographic method for analysis of cephradine in human plasma samples

    International Nuclear Information System (INIS)

    Ahmad, M.; Usman, M.; Madni, A.; Akhtar, N.; Khalid, N.; Asghar, W.

    2010-01-01

    An HPLC method with high precision, accuracy and selectivity was developed and validated for the assessment of cephradine in human plasma samples. The extraction procedure was simple and accurate with single step followed by direct injection of sample into HPLC system. The extracted cephradine in spiked human plasma was separated and quantitated using reversed phase C/sub 18/ column and UV detection wavelength of 254 nm. The optimized mobile phase of new composition of 0.05 M potassium dihydrogen phosphate (pH 3.4)-acetonitrile (88: 12) was pumped at an optimum flow rate of 1 mL.min/sup 1/. The method resulted linearity in the concentration range 0.15- 20 micro g mL/sup -1/. The limit of detection (LOD) and limit of quantification (LOQ) were 0.05 and 0.150 Microg.mL/sup -1/, respectively. The accuracy of method was 98.68 %. This method can 1>e applied for bioequivalence studies and therapeutic drug monitoring as well as for the routine analysis of cephradine. (author)

  19. Method Performance of Total Mercury (Hg) Testing in the Biological Samples by Using Cold Vapour Atomic Absorption Spectrophotometer (CV-AAS)

    International Nuclear Information System (INIS)

    Susanna TS; Samin

    2007-01-01

    Method performance (validation) of total mercury (Hg) testing in the biological samples by using cold vapour atomic absorption spectrophotometer (CV-AAS) has been done. The objective of this research is to know the method performance of CV-AAS as one of points for the accreditation testing of laboratory according IS0/IEC 17025-2005. The method performance covering limit of detection (LOD), accuracy, precision and bias. As a standard material used SRM Oyster Tissue 15660 from Winopal Forshung Germany, whereas the biological samples were human hair. In principle of mercury testing for solid samples using CV-AAS is dissolving this sample and standard with 10 mL HNO 3 supra pure into a closed quartz tube and heating at 150 °C for 4 hours. The concentration of mercury in each samples was determined at the condition of operation were stirring time (T 1 ) 70 seconds, delay time (T 2 ) 15 seconds, heating time (T 3 ) 13 seconds and cooling time (T 4 ) of 25 seconds. Mercury ion in samples are reduced with SnCl 2 10 % in H 2 SO 4 20 %, and then the vapour of mercury from reduction is passed in NaOH 20 % solution and aquatridest. The result of method performance were: limit of detection (LOD) = 0.085 ng, accuracy 99.70 %, precision (RSD) = 1.64 % and bias = 0.30 %. From the validation result showed that the content of mercury total was in the range of certified values. The total mercury content (Hg) in human hair were varied from 406.93 - 699.07 ppb. (author)

  20. Spacelab Life Science-1 Mission Onboard Photograph

    Science.gov (United States)

    1995-01-01

    Spacelab Life Science -1 (SLS-1) was the first Spacelab mission dedicated solely to life sciences. The main purpose of the SLS-1 mission was to study the mechanisms, magnitudes, and time courses of certain physiological changes that occur during space flight, to investigate the consequences of the body's adaptation to microgravity and readjustment to Earth's gravity, and bring the benefits back home to Earth. The mission was designed to explore the responses of the heart, lungs, blood vessels, kidneys, and hormone-secreting glands to microgravity and related body fluid shifts; examine the causes of space motion sickness; and study changes in the muscles, bones, and cells. This photograph shows astronaut Rhea Seddon conducting an inflight study of the Cardiovascular Deconditioning experiment by breathing into the cardiovascular rebreathing unit. This experiment focused on the deconditioning of the heart and lungs and changes in cardiopulmonary function that occur upon return to Earth. By using noninvasive techniques of prolonged expiration and rebreathing, investigators can determine the amount of blood pumped out of the heart (cardiac output), the ease with which blood flows through all the vessels (total peripheral resistance), oxygen used and carbon dioxide released by the body, and lung function and volume changes. SLS-1 was launched aboard the Space Shuttle Orbiter Columbia (STS-40) on June 5, 1995.

  1. Analysis of abandoned potential CERCLA hazardous waste sites using historic aerial photographs

    International Nuclear Information System (INIS)

    Rosowitz, D.W.; Franzen, P.A.; Green, D.J.

    1993-01-01

    Aerial photographs of varying scale from federal agencies and commercial aerial service companies covering the years 1938, 1942, 1948, 1952, 1957, 1960, 1970, 1971, 1977, and 1986 of the Edgewood Area of Aberdeen Proving Ground (APG), Maryland, (Gunpowder Neck 7.5 Minute United States Geological Survey Topographic Quadrangle Map) were evaluated for identification of potential Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) hazardous waste sites and land use changes for approximately 1500 acres (610 hectares) used in the testing of military-related chemicals and munitions on Carroll Island and Graces Quarters. Detailed testing records exist only for July 1964 to December 1971, thus making the interpretation of aerial photographs a valuable tool in reconstructing past activities from the late 1930s to June 1964 and guiding future sampling locations in the multiphased CERCLA process. Many potential test sites were activated by either clear-cutting tracks of vegetation or using existing cleared land until final abandonment of the site(s) circa 1974-1975. Ground inspection of open-quotes land scarringclose quotes at either known or suspected sites was essential for verifying the existence, location, and subsequent sampling of potential CERCLA sites. Photomorphic mapping techniques are described to delineate and compare different land use changes in past chemical and munitions handling and testing. Delineation of features was based on photographic characteristics of tone, pattern, texture, shape, shadow, size, and proximity to known features. 7 refs., 9 figs

  2. New methods for sampling sparse populations

    Science.gov (United States)

    Anna Ringvall

    2007-01-01

    To improve surveys of sparse objects, methods that use auxiliary information have been suggested. Guided transect sampling uses prior information, e.g., from aerial photographs, for the layout of survey strips. Instead of being laid out straight, the strips will wind between potentially more interesting areas. 3P sampling (probability proportional to prediction) uses...

  3. The peculiar A star HD 110066: a photographic region line identification study

    International Nuclear Information System (INIS)

    Adelman, S.J.

    1988-01-01

    A line identification study of the very sharp-lined peculiar A star HD 110066 has been performed using four high dispersion photographic region spectrograms. New species found include Al I, Si I, S II, Ti I, Co II, Zr II, Cd I, La II, Ce III, Gd III, Dy II, Er II and Tm II. The presence of these species is in accord with the continuity of the magnetic Ap star sequence. (author)

  4. Peculiar A star HD 43819 - A photographic region line-identification study

    International Nuclear Information System (INIS)

    Adelman, S.J.; The Citadel, Charleston, SC)

    1985-01-01

    A line identification study of the sharp-lined silicon star HD 43819 has been performed for the photographic region 3759-4924 A. Comparison of this star's spectrum with those of other silicon stars shows that it shares many of their apparent abundance anomalies. The TiII, CrII, FeI, and FeII spectra are well represented while the singly ionized rare earths are represented by at best a few lines per species. 21 references

  5. Optimal wavelet transform for the detection of microaneurysms in retina photographs

    OpenAIRE

    Quellec, Gwénolé; Lamard, Mathieu; Josselin, Pierre Marie; Cazuguel, Guy; Cochener, Béatrice; Roux, Christian

    2008-01-01

    11 pages; International audience; In this paper, we propose an automatic method to detect microaneurysms in retina photographs. Microaneurysms are the most frequent and usually the first lesions to appear as a consequence of diabetic retinopathy. So, their detection is necessary for both screening the pathology and follow up (progression measurement). Automating this task, which is currently performed manually, would bring more objectivity and reproducibility. We propose to detect them by loc...

  6. Refracted Gazes: A Woman Photographer during Mandate Lebanon

    Directory of Open Access Journals (Sweden)

    Yasmine Nachabe

    2012-11-01

    This paper explores the relationship between modernity and femininity as manifest through the women’s activity, gaze and attire in Marie al-Khazen as well as other photographs taken in the Middle East region between the 1930s and the 1940s. Al-Khazen and the women represented in the photographs of this period were part of a cosmopolitan sensibility that reveals the Middle East region to be far more international than one might have imagined. Caught between projecting a self-image of the cosmopolitan woman and one of the traditional bedouin, these photographs provide a rich field for tracking the ambiguities of the modern.

  7. Calculation and construction of electron-diffraction photographs using computer

    International Nuclear Information System (INIS)

    Khayurov, S.S.; Notkin, A.B.

    1981-01-01

    A method of computer construction and indexing of theoretical electronograms for monophase structures with arbitrary type of crystal lattice and for polyphase ones with known orientational coorrelations between phases is presented. Electron-diffraction photograph is presented, obtained from the foil area of two-phase VT22 alloy at β phase orientation in comparison with theoretical electron-diffraction photographs, built ap by computer, with the [100] β phase zone axis and with three variants of α phase orientation relatively to β phase. It is shown that on the experimental electron-diffraction photograph simultaneously presents α-phase three orientations, which reflexes can be indexing correctly [ru

  8. Adsorptive behavior and solid-phase microextraction of bare stainless steel sample loop in high performance liquid chromatography.

    Science.gov (United States)

    Zhang, Wenpeng; Zhang, Zixin; Meng, Jiawei; Zhou, Wei; Chen, Zilin

    2014-10-24

    In this work, we interestingly happened to observe the adsorption of stainless steel sample loop of HPLC. The adsorptive behaviors of the stainless steel loop toward different kinds of compounds were studied, including polycyclic aromatic hydrocarbons (PAHs), halogeno benzenes, aniline derivatives, benzoic acid derivatives, phenols, benzoic acid ethyl ester, benzaldehyde, 1-phenyl-ethanone and phenethyl alcohol. The adsorptive mechanism was probably related to hydrophobic interaction, electron-rich element-metal interaction and hydrogen bond. Universal adsorption of stainless steels was also testified. Inspired by its strong adsorptive capability, bare stainless steel loop was developed as a modification-free in-tube device for solid-phase microextraction (SPME), which served as both the substrate and sorbent and possessed ultra-high strength and stability. Great extraction efficiency toward PAHs was obtained by stainless steel loop without any modification, with enrichment factors of 651-834. By connecting the stainless steel loop onto a six-port valve, an online SPME-HPLC system was set up and an SPME-HPLC method has been validated for determination of PAHs. The method has exceptionally low limits of detection of 0.2-2pg/mL, which is significantly lower than that of reported methods with different kinds of sorbents. Wide linear range (0.5-500 and 2-1000pg/mL), good linearity (R(2)≥0.9987) and good reproducibility (RSD≤2.9%) were also obtained. The proposed method has been applied to determine PAHs in environmental samples. Good recoveries were obtained, ranging from 88.5% to 93.8%. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. The effects of armodafinil on objective sleepiness and performance in a shift work disorder sample unselected for objective sleepiness.

    Science.gov (United States)

    Howard, Ryan; Roth, Thomas; Drake, Christopher L

    2014-06-01

    Armodafinil is a medication used to treat excessive sleepiness in individuals with shift work disorder (SWD). In the present study, we investigate whether armodafinil can normalize nocturnal sleepiness in a group of typical SWD patients. Participants were 12 night workers (aged 33.8 ± 8.57 years, 7 female subjects) with excessive sleepiness (≥10 on the Epworth Sleepiness Scale; mean, 14.8 ± 3.16), meeting the International Classification of Sleep Disorders, Second Edition criteria for SWD, with no other sleep or medical disorders verified by polysomnogram. The multiple sleep latency test (MSLT) was not used as an entry criteria. Armodafinil was administered at 10:30 pm in a randomized, double-blind, placebo-controlled, crossover design with experimental nights separated by 1 week. Primary end point was the MSLT, with naps at 1:30, 3:30, 5:30, and 7:30 am. Other study measures included a sleepiness-alertness visual analog scale administered before each nap, and 2 computer-based performance tests evaluating attention and memory. Subjects with SWD had a mean MSLT of 5.3 ± 3.25 minutes, indicating a mean level of pathological sleepiness. Armodafinil significantly improved MSLT score to 11.1 ± 4.79 minutes (P = 0.006). Subjective levels of alertness on the visual analog scale also improved (P = 0.008). For performance, reaction time to central (P = 0.006) and peripheral (P = 0.003) stimuli and free recall memory (P = 0.05) were also improved. Armodafinil 150 mg administered at the beginning of a night shift normalizes nocturnal sleepiness in individuals with SWD unselected for objective sleepiness. Subjective measures of sleepiness and cognitive performance are also improved. This suggests that armodafinil can improve levels of nocturnal alertness to within normal daytime levels in the majority of patients with SWD.

  10. Effects of Creating Awareness Through Photographs and Posters on Skin Self-Examination in Nursing Students.

    Science.gov (United States)

    Erkin, Özüm; Ardahan, Melek; Temel, Ayla Bayık

    2018-02-01

    Nurses can have an influence on primary and secondary prevention of skin cancer. Therefore, it is important to help them acquire knowledge and skills necessary to modify behavior in relation to skin cancers. The aim of this study was to examine effects of creating awareness through photographs and posters on knowledge and skills of skin self-examination in nursing students. The study had a quasi-experimental design with a pretest and a posttest in a single group. The study population included 249 last-year nursing students in Turkey. Non-probability sampling was used to reach the population. The study sample was composed of 201 students volunteering to participate in the study, and the response rate was 81 %. Of the students, 85.1 % (n = 171) were female and the mean age of the students was 22.18 ± 0.78 years. Of the students, 94.5 % did not know the asymmetry, border, color, diameter, evolution (ABCDE) criteria on the pretest, but this rate decreased to 20.9 % on the posttest. The mean score for knowledge of symptoms of skin cancer was 10.95 ± 1.37 on the pretest and 11.48 ± 0.90 on the posttest. There was a significant linear increase in the scores for knowledge of the symptoms (F = 7.874, p < 0.001) after the intervention with photographs and posters. The students were observed to learn the ABCDE criteria and had increased knowledge of skin cancer symptoms after the intervention using photographs and posters. Photographs and posters are effective tools which can be used to increase awareness of skin self-examination.

  11. Confirmation of congenital adrenal hyperplasia by adrenal steroid profiling of filter paper dried blood samples using ultra-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Rossi, Claudia; Calton, Lisa; Brown, Heather A; Gillingwater, Scott; Wallace, A Michael; Petrucci, Francesca; Ciavardelli, Domenico; Urbani, Andrea; Sacchetta, Paolo; Morris, Michael

    2011-04-01

    The specificity of screening for congenital adrenal hyperplasia by direct measurement of 17-hydroxyprogesterone in filter paper dried blood spot samples by immunoassay is low and has a high false-positive rate. In order to reduce the false-positive rate of this test, we developed a rapid, robust, specific confirmatory procedure in which cortisol, 4-androstene-3,17-dione and 17-hydroxyprogesterone were measured simultaneously by ultra-performance liquid chromatography-tandem mass spectrometry. After extraction, samples were analysed by ultra-performance liquid chromatography-tandem mass spectrometry and 17-hydroxyprogesterone was quantified accurately. Other steroids were determined using stable deuterated internal standards. In total, 25 patient blood spot samples and 92 control samples were analysed. The assay was linear for 17-hydroxyprogesterone, with a coefficient of determination >0.997 and imprecision ≤ 6.5%. An upper limit of normal for 17-hydroxyprogester-one of 4.45 nmol/L was established by analysing a cohort of samples from unaffected newborns. In addition, a cut-off of 3.5 for the peak areas ratio (17-hydroxyprogesterone+4-androstene-3,17-dione)/cortisol, allows confirmation of the affected steroidogenic enzyme. A high throughput method for the detection of steroids related to congenital adrenal hyperplasia has been developed, allowing the false-positive rate associated with screening for 17-hydroxyprogesterone by immunoassay to be determined.

  12. Diagnosing dementia and normal aging: clinical relevance of brain ratios and cognitive performance in a Brazilian sample

    Directory of Open Access Journals (Sweden)

    Chaves M.L.F.

    1999-01-01

    Full Text Available The main objective of the present study was to evaluate the diagnostic value (clinical application of brain measures and cognitive function. Alzheimer and multiinfarct patients (N = 30 and normal subjects over the age of 50 (N = 40 were submitted to a medical, neurological and cognitive investigation. The cognitive tests applied were Mini-Mental, word span, digit span, logical memory, spatial recognition span, Boston naming test, praxis, and calculation tests. The brain ratios calculated were the ventricle-brain, bifrontal, bicaudate, third ventricle, and suprasellar cistern measures. These data were obtained from a brain computer tomography scan, and the cutoff values from receiver operating characteristic curves. We analyzed the diagnostic parameters provided by these ratios and compared them to those obtained by cognitive evaluation. The sensitivity and specificity of cognitive tests were higher than brain measures, although dementia patients presented higher ratios, showing poorer cognitive performances than normal individuals. Normal controls over the age of 70 presented higher measures than younger groups, but similar cognitive performance. We found diffuse losses of tissue from the central nervous system related to distribution of cerebrospinal fluid in dementia patients. The likelihood of case identification by functional impairment was higher than when changes of the structure of the central nervous system were used. Cognitive evaluation still seems to be the best method to screen individuals from the community, especially for developing countries, where the cost of brain imaging precludes its use for screening and initial assessment of dementia.

  13. Automated syndrome detection in a set of clinical facial photographs.

    Science.gov (United States)

    Boehringer, Stefan; Guenther, Manuel; Sinigerova, Stella; Wurtz, Rolf P; Horsthemke, Bernhard; Wieczorek, Dagmar

    2011-09-01

    Computer systems play an important role in clinical genetics and are a routine part of finding clinical diagnoses but make it difficult to fully exploit information derived from facial appearance. So far, automated syndrome diagnosis based on digital, facial photographs has been demonstrated under study conditions but has not been applied in clinical practice. We have therefore investigated how well statistical classifiers trained on study data comprising 202 individuals affected by one of 14 syndromes could classify a set of 91 patients for whom pictures were taken under regular, less controlled conditions in clinical practice. We found a classification accuracy of 21% percent in the clinical sample representing a ratio of 3.0 over a random choice. This contrasts with a 60% accuracy or 8.5 ratio in the training data. Producing average images in both groups from sets of pictures for each syndrome demonstrates that the groups exhibit large phenotypic differences explaining discrepancies in accuracy. A broadening of the data set is suggested in order to improve accuracy in clinical practice. In order to further this goal, a software package is made available that allows application of the procedures and contributions toward an improved data set. Copyright © 2011 Wiley-Liss, Inc.

  14. Alignment and referencing of maps and aerial photographs

    International Nuclear Information System (INIS)

    Cullings, Harry M.; Fujita, Shoichiro; Hoshi, Masaharu; Egbert, Stephen D.; Kerr, George D.

    2005-01-01

    Documentation of survivor locations as well as sample collection sites for dosimetry-related measurements requires reference to suitable maps. The maps traditionally used at RERF for these purposes are the U.S. Army maps that date from circa 1945 (see Chapter 1). In later years, some use has been made of Japanese city plan maps, which are much newer (1979 in Hiroshima and 1981 in Nagasaki) and of larger scale (1:2,500 vs. 1:12,500 for the U.S. Army maps). Even before the publication of DS86, efforts were made to reconcile the locations of buildings and other features of interest on these two sets of maps. Beyond the simple desire to compare two different sources of map information, it was thought that a better standard of accuracy for technical reasons could be achieved with the use of the newer maps. The U.S. Army maps were compiled under wartime conditions from an assortment of older Japanese maps and other sources, including aerial photographs of limited quality, using the best methods available at the time. The newer Japanese maps had the benefit of 34 years of improvement in cartographic methods and were made with extensive new survey information. Because of their larger scale, they are also more detailed than the U.S. Army maps. (J.P.N.)

  15. Environmental sampling

    International Nuclear Information System (INIS)

    Puckett, J.M.

    1998-01-01

    Environmental Sampling (ES) is a technology option that can have application in transparency in nuclear nonproliferation. The basic process is to take a sample from the environment, e.g., soil, water, vegetation, or dust and debris from a surface, and through very careful sample preparation and analysis, determine the types, elemental concentration, and isotopic composition of actinides in the sample. The sample is prepared and the analysis performed in a clean chemistry laboratory (CCL). This ES capability is part of the IAEA Strengthened Safeguards System. Such a Laboratory is planned to be built by JAERI at Tokai and will give Japan an intrinsic ES capability. This paper presents options for the use of ES as a transparency measure for nuclear nonproliferation

  16. Determination of captopril in biological samples by high-performance liquid chromatography with ThioGlo 3 derivatization.

    Science.gov (United States)

    Aykin, N; Neal, R; Yusof, M; Ercal, N

    2001-11-01

    Captopril, a well-known angiotensin converting enzyme (ACE) inhibitor, is widely used for treatment of arterial hypertension. Recent studies suggest that it may also act as a scavenger of free radicals because of its thiol group. Therefore, the present study describes a rapid, sensitive and relatively simple method for the detection of captopril in biological tissues with reverse-phase HPLC. Captopril was first derivatized with ThioGlo 3 [3H-Naphto[2,1-b]pyran,9-acetoxy-2-(4-(2,5-dihydro-2,5-dioxo-1H-pyrrol-1-yl)phenyl-3-oxo-)]. It was then detected by fluorescence-HPLC using an Astec C(18) column as the stationary phase and a water:acetonitrile:acetic acid:phosphoric acid mixture (50:50; 1 mL/L acids) as the mobile phase (excitation wavelength, 365 nm; emission wavelength, 445 nm). The calibration curve for captopril was linear over a range of 10-2500 nM and the coefficient of variation acquired for the within- and between-run precision for captopril was 0.5 and 3.8%, respectively. The detection limit of captopril with this method was found to be 200 fmol/20 microL injection volume. Its relative recovery from biological samples was determined to the range from 93.3 to 105.3%. Based on these results, we believe that our method is advantageous for captopril determination. Copyright 2001 John Wiley & Sons, Ltd.

  17. Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-11-01

    Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Aliquots of 20 venous samples were adjusted to the following pO2 values: oxygen sensitive. © 2013 Diabetes Technology Society.

  18. Arsenic speciation in seafood samples with emphasis on minor constituents. An investigation by high performance liquid chromatography with inductively coupled plasma mass spectrometric detection

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Pritzl, G.; Hansen, S. H.

    1993-01-01

    Extracts of 11 samples of shrimp, crab, fish, fish liver, shellfish and lobster digestive gland (hepatopancreas), including five certified reference materials, were investigated for their contents of arsenic compounds (arsenic speciation). The cation-exchange high performance liquid chromatography...... (as arsenic atom) relative to the total arsenic extracted from the samples were: arsenobetaine 19-98%, arsenocholine and trimethylarsine oxide 0-0.6% and the trimethylarsonium ion 0-2.2%. Additionally, an unknown arsenic species (U1) was present at 3.1-18% in the shellfish and in the lobster digestive...

  19. Adsorptioin performance of modified nkalagu bentonite in dye removal: kinetics, equilibrium, thermodynamics and structureal properties of the modified samples

    International Nuclear Information System (INIS)

    Ajemba, R.O.

    2015-01-01

    The adsorption performance of modified Nkalagu bentonite in removing Congo red (CR) from solution was investigated. The raw bentonite was modified by three different physicochemical methods: thermal activation (TA), acid activation (AA), and combined acid and thermal activation (ATA). The Congo red adsorption increased with increase in contact time, initial dye concentration, adsorbent dosage, temperature, and pH change. The results of the kinetics analysis of the adsorption data revealed that adsorption follows pseudo second-order kinetics. Analysis of the equilibrium data showed that Langmuir isotherm provided a better fit to the data. Evaluation of the thermodynamic parameters revealed that adsorption process is spontaneous and endothermic. The results from this study suggest that a combination of thermal and acid activation is an effective modification method to improve adsorption capacity of bentonite and makes the bentonite as low-cost adsorbent for removal of water pollutants. (author)

  20. Martin Parr in Mexico: Does Photographic Style Translate?

    Directory of Open Access Journals (Sweden)

    Timothy R. Gleason

    2011-11-01

    Full Text Available This study analyzes Martin Parr’s 2006 photobook, Mexico. Parr is a British documentary photographer best known for a direct photographic style that reflects upon “Englishness.”Mexico is his attempt to understand this foreign country via his camera. Mexico, as a research subject, is not a problem to solve but an opportunity to understand a photographer’s work. Parr’s Mexico photography (technique, photographic content, and interest in globalization, economics, and culture is compared to his previous work to explain how Parr uses fashion and icons to represent a culture or class. This article argues Parr’s primary subjects, heads/hats, food, and Christs, are photographed without excessive aesthetic pretensions so that the thrust of Parr’s message about globalization can be more evident:Mexico maintains many of its traditions and icons while adopting American brands.

  1. Improvements in televisual and photographic inspections of AGRs

    International Nuclear Information System (INIS)

    Hayter, R.; Wadsworth, A.

    1988-01-01

    The visual inspection techniques and equipment used at AGR Power Stations have been improved and updated in the light of need and technological advance, new equipment being developed and introduced where necessary. Specifically this report covers the development and use of: a short TRIUMPH compatible photographic camera 600 mm long x 75 mm dia taking 50 shots on a 35 mm film; a 240 mm dia photographic pod taking high quality 70 mm format photographs of large in-reactor volumes; a photographic camera of cross section 37 x 17 mm for the inspection of helically wound AGR boilers and the subsequent development of this latter device into a state of the art TV inspection camera. (author)

  2. Photographic atlas of fish otoliths of the Northwest Atlantic Ocean

    National Research Council Canada - National Science Library

    Campana, Steven E

    2004-01-01

    This photographic atlas presents light and (or) scanning electron micrographs of 580 pairs of sagittal otoliths representing 288 species, 97 families, and 27 orders of fish from the northwest Atlantic...

  3. 7 CFR 97.9 - Drawings and photographs.

    Science.gov (United States)

    2010-01-01

    ...) Drawings or photographs shall be in color when color is a distinguishing characteristic of the variety, and the color shall be described by use of Nickerson's or other recognized color chart. (c) Drawings...

  4. Project Birdseye Aerial Photograph Collection: Digital and Analog Materials

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This collection consists of both analog and digital aerial photographs from Arctic areas in and around Baffin Bay, the Labrador Sea, the Arctic Ocean, the Beaufort...

  5. Post-Processing Resolution Enhancement of Open Skies Photographic Imagery

    National Research Council Canada - National Science Library

    Sperl, Daniel

    2000-01-01

    ...), which manages implementation of the Open Skies Treaty for the US Air Force, wants to determine if post-processing of the photographic images can improve spatial resolution beyond 30 cm, and if so...

  6. A multiobserver study of the effects of including point-of-care patient photographs with portable radiography: a means to detect wrong-patient errors.

    Science.gov (United States)

    Tridandapani, Srini; Ramamurthy, Senthil; Provenzale, James; Obuchowski, Nancy A; Evanoff, Michael G; Bhatti, Pamela

    2014-08-01

    To evaluate whether the presence of facial photographs obtained at the point-of-care of portable radiography leads to increased detection of wrong-patient errors. In this institutional review board-approved study, 166 radiograph-photograph combinations were obtained from 30 patients. Consecutive radiographs from the same patients resulted in 83 unique pairs (ie, a new radiograph and prior, comparison radiograph) for interpretation. To simulate wrong-patient errors, mismatched pairs were generated by pairing radiographs from different patients chosen randomly from the sample. Ninety radiologists each interpreted a unique randomly chosen set of 10 radiographic pairs, containing up to 10% mismatches (ie, error pairs). Radiologists were randomly assigned to interpret radiographs with or without photographs. The number of mismatches was identified, and interpretation times were recorded. Ninety radiologists with 21 ± 10 (mean ± standard deviation) years of experience were recruited to participate in this observer study. With the introduction of photographs, the proportion of errors detected increased from 31% (9 of 29) to 77% (23 of 30; P = .006). The odds ratio for detection of error with photographs to detection without photographs was 7.3 (95% confidence interval: 2.29-23.18). Observer qualifications, training, or practice in cardiothoracic radiology did not influence sensitivity for error detection. There is no significant difference in interpretation time for studies without photographs and those with photographs (60 ± 22 vs. 61 ± 25 seconds; P = .77). In this observer study, facial photographs obtained simultaneously with portable chest radiographs increased the identification of any wrong-patient errors, without substantial increase in interpretation time. This technique offers a potential means to increase patient safety through correct patient identification. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  7. Simultaneous extraction and quantification of lamotrigine, phenobarbital, and phenytoin in human plasma and urine samples using solidified floating organic drop microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Asadi, Mohammad; Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Abbasi, Bijan

    2015-07-01

    A novel and simple method based on solidified floating organic drop microextraction followed by high-performance liquid chromatography with ultraviolet detection has been developed for simultaneous preconcentration and determination of phenobarbital, lamotrigine, and phenytoin in human plasma and urine samples. Factors affecting microextraction efficiency such as the type and volume of the extraction solvent, sample pH, extraction time, stirring rate, extraction temperature, ionic strength, and sample volume were optimized. Under the optimum conditions (i.e. extraction solvent, 1-undecanol (40 μL); sample pH, 8.0; temperature, 25°C; stirring rate, 500 rpm; sample volume, 7 mL; potassium chloride concentration, 5% and extraction time, 50 min), the limits of detection for phenobarbital, lamotrigine, and phenytoin were 1.0, 0.1, and 0.3 μg/L, respectively. Also, the calibration curves for phenobarbital, lamotrigine, and phenytoin were linear in the concentration range of 2.0-300.0, 0.3-200.0, and 1.0-200.0 μg/L, respectively. The relative standard deviations for six replicate extractions and determinations of phenobarbital, lamotrigine, and phenytoin at 50 μg/L level were less than 4.6%. The method was successfully applied to determine phenobarbital, lamotrigine, and phenytoin in plasma and urine samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Digitising photographs for small museums and historical societies

    OpenAIRE

    Holley, Rose

    2005-01-01

    Many small museums and historical societies have recently embarked on digitisation projects, or are investigating how they can make a start. Most commonly these projects involve digitisation of photographs or negatives. This paper gives a general overview of why we might want to do this, the benefits, the issues, and some tips for starting. A case study of a photograph digitisation project that was carried out at the University of Auckland is then described in detail.

  9. Neural correlates for perception of companion animal photographs.

    Science.gov (United States)

    Hayama, Sara; Chang, Linda; Gumus, Kazim; King, George R; Ernst, Thomas

    2016-05-01

    Anthrozoological neuroscience, which we propose as the use of neuroscience techniques to study human-animal interaction, may help to elucidate mechanisms underlying the associated psychological, physiological, and other purported health effects. This preliminary study investigates the neural response to animal photographs in pet owners and non-pet owners, and both attraction and attachment to companion animals as modulators of human perception of companion animal photographs. Thirty male participants, 15 "Pet Owners" (PO) and 15 "Non-Pet Owners" (NPO), viewed photographs of companion animals during functional MRI (fMRI) scans at 3 T and provided ratings of attraction to the animal species represented in the photographs. Fourteen subjects additionally submitted and viewed personal pet photographs during fMRI scans, and completed the Lexington Attachment to Pets Scale (LAPS). PO exhibited greater activation than NPO during the viewing of animal photographs in areas of the insula, and frontal and occipital cortices. Moreover, ratings of attraction to animals correlated positively with neural activation in the cingulate gyrus, precentral gyrus, inferior parietal lobule, and superior temporal gyrus during the viewing of representative photographs. For subjects with household pets, scores on the LAPS correlated positively with neural activation during the viewing of owned pet photographs in the precuneus, cuneus, and superior parietal lobule. Our preliminary findings suggest that human perception of companion animals involve the visual attention network, which may be modulated at the neural level by subjective experiences of attraction or attachment to animals. Our understanding of human-animal interactions through anthrozoological neuroscience may better direct therapeutic applications, such as animal-assisted therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Forehardened photographic elements and their use in radiography

    International Nuclear Information System (INIS)

    Dickerson, R.E.

    1983-01-01

    This U.K. patent application relates to forehardened photographic elements, particularly radiographic elements having among hydrophilic colloid layers at least one emulsion layer wherein thin tabular silver halide grains having a thickness of less than 0.3 micrometer provide at least 50 percent of the total projected grain area. When developed in less than 1 minute to produce a viewable silver image, these photographic elements exhibit increased covering power. Methods of preparing the tabular grain silver halide emulsions are described. (author)

  11. Identification of Active Faults by Aerial Photograph Interpretation and Case

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.R.; Chang, C.J.; Choi, W.H.; Yun, K.H.; Park, D.H.; Shin, S.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    This report is the technical memo of the research project entitled ''Development of Technology of Advanced Seismic Safety Assessment for NPP sites''. The purposes of this report are to describe analysis methods of photographic characteristics related with active faults, to identify active faults by aerial photograph interpretation and to review case studies. (author). 27 refs., 165 figs., 8 tabs.

  12. Evaluation of Factors Affecting Continuous Performance Test Identical Pairs Version Score of Schizophrenic Patients in a Japanese Clinical Sample

    Directory of Open Access Journals (Sweden)

    Takayoshi Koide

    2012-01-01

    Full Text Available Aim. Cognitive impairment in schizophrenia strongly relates to social outcome and is a good candidate for endophenotypes. When we accurately measure drug efficacy or effects of genes or variants relevant to schizophrenia on cognitive impairment, clinical factors that can affect scores on cognitive tests, such as age and severity of symptoms, should be considered. To elucidate the effect of clinical factors, we conducted multiple regression analysis using scores of the Continuous Performance Test Identical Pairs Version (CPT-IP, which is often used to measure attention/vigilance in schizophrenia. Methods. We conducted the CPT-IP (4-4 digit and examined clinical information (sex, age, education years, onset age, duration of illness, chlorpromazine-equivalent dose, and Positive and Negative Symptom Scale (PANSS scores in 126 schizophrenia patients in Japanese population. Multiple regression analysis was used to evaluate the effect of clinical factors. Results. Age, chlorpromazine-equivalent dose, and PANSS-negative symptom score were associated with mean d′ score in patients. These three clinical factors explained about 28% of the variance in mean d′ score. Conclusions. As conclusion, CPT-IP score in schizophrenia patients is influenced by age, chlorpromazine-equivalent dose and PANSS negative symptom score.

  13. Performances on Rey Auditory Verbal Learning Test and Rey Complex Figure Test in a healthy, elderly Danish sample--reference data and validity issues

    DEFF Research Database (Denmark)

    Vogel, Asmus; Stokholm, Jette; Jørgensen, Kasper

    2012-01-01

    . The RCFT copy score was significantly related to age and the DART score. On RCFT recall a highly significant difference was found between persons who could make a faultless copy and persons with incomplete copy performance. Thus, this study presents separate data for RCFT recall scores according...... to the subjects' copying performance (in separate tables for age and education groups). For all measures on both RAVLT and RCFT wide distributions of scores were found and the impact of this broad score range on the tests' discriminative validity is discussed. RAVLT performances for elderly were similar...... to previous published meta-norms, but the included sample of elderly Danes performed better on RCFT (copy and recall) than elderly from the United States....

  14. Impact of mental disorders on work performance in a community sample of workers in Japan: the World Mental Health Japan Survey 2002-2005.

    Science.gov (United States)

    Tsuchiya, Masao; Kawakami, Norito; Ono, Yutaka; Nakane, Yoshibumi; Nakamura, Yosikazu; Fukao, Akira; Tachimori, Hisateru; Iwata, Noboru; Uda, Hidenori; Nakane, Hideyuki; Watanabe, Makoto; Oorui, Masashi; Naganuma, Yoichi; Furukawa, Toshiaki A; Kobayashi, Masayo; Ahiko, Tadayuki; Takeshima, Tadashi; Kikkawa, Takehiko

    2012-06-30

    Most studies that investigate the impact of mental disorders on work performance have been conducted in Western countries, but this study examines the impact of common mental disorders on sick leave and on-the-job work performance in a community sample of Japanese workers. Data from the World Mental Health Japan survey were analyzed. A subsample of 530 workers aged 20-60years were interviewed using the WHO Composite International Diagnostic Interview 3.0. The WHO Health and Work Performance Questionnaire, was used to assess sick days and on-the-job work performance for the previous 30days. Linear regression was used to estimate the impact of mental disorders on these indicators of work performance over 12months. Mood disorders, including major depressive disorder, and alcohol abuse/dependence were significantly associated with decreased on-the-job performance. There were no significant associations between mental disorders and sick/absent days. Consistent with previous studies, major depression has a great impact on on-the-job work performance in Japan. The lost productivity was estimated at approximately 28-30 lost days per year. A similar decrease in on-the-job work performance was found for alcohol abuse/dependence, which is stronger than that in other countries, probably attributable to greater tolerance of problematic drinking at Japanese worksites. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Manual versus automated streaking system in clinical microbiology laboratory: Performance evaluation of Previ Isola for blood culture and body fluid samples.

    Science.gov (United States)

    Choi, Qute; Kim, Hyun Jin; Kim, Jong Wan; Kwon, Gye Cheol; Koo, Sun Hoe

    2018-01-04

    The process of plate streaking has been automated to improve routine workflow of clinical microbiology laboratories. Although there were many evaluation reports about the inoculation of various body fluid samples, few evaluations have been reported for blood. In this study, we evaluated the performance of automated inoculating system, Previ Isola for various routine clinical samples including blood. Blood culture, body fluid, and urine samples were collected. All samples were inoculated on both sheep blood agar plate (BAP) and MacConkey agar plate (MCK) using Previ Isola and manual method. We compared two methods in aspect of quality and quantity of cultures, and sample processing time. To ensure objective colony counting, an enumeration reading reference was made through a preliminary experiment. A total of 377 nonduplicate samples (102 blood culture, 203 urine, 72 body fluid) were collected and inoculated. The concordance rate of quality was 100%, 97.0%, and 98.6% in blood, urine, and other body fluids, respectively. In quantitative aspect, it was 98.0%, 97.0%, and 95.8%, respectively. The Previ Isola took a little longer to inoculate the specimen than manual method, but the hands-on time decreased dramatically. The shortened hands-on time using Previ Isola was about 6 minutes per 10 samples. We demonstrated that the Previ Isola showed high concordance with the manual method in the inoculation of various body fluids, especially in blood culture sample. The use of Previ Isola in clinical microbiology laboratories is expected to save considerable time and human resources. © 2018 Wiley Periodicals, Inc.

  16. Quantitative evaluation of papilledema from stereoscopic color fundus photographs.

    Science.gov (United States)

    Tang, Li; Kardon, Randy H; Wang, Jui-Kai; Garvin, Mona K; Lee, Kyungmoo; Abràmoff, Michael D

    2012-07-03

    To derive a computerized measurement of optic disc volume from digital stereoscopic fundus photographs for the purpose of diagnosing and managing papilledema. Twenty-nine pairs of stereoscopic fundus photographs and optic nerve head (ONH) centered spectral domain optical coherence tomography (SD-OCT) scans were obtained at the same visit in 15 patients with papilledema. Some patients were imaged at multiple visits in order to assess their changes. Three-dimensional shape of the ONH was estimated from stereo fundus photographs using an automated multi-scale stereo correspondence algorithm. We assessed the correlation of the stereo volume measurements with the SD-OCT volume measurements quantitatively, in terms of volume of retinal surface elevation above a reference plane and also to expert grading of papilledema from digital fundus photographs using the Frisén grading scale. The volumetric measurements of retinal surface elevation estimated from stereo fundus photographs and OCT scans were positively correlated (correlation coefficient r(2) = 0.60; P photographs compares favorably with that from OCT scans and with expert grading of papilledema severity. Stereoscopic color imaging of the ONH combined with a method of automated shape reconstruction is a low-cost alternative to SD-OCT scans that has potential for a more cost-effective diagnosis and management of papilledema in a telemedical setting. An automated three-dimensional image analysis method was validated that quantifies the retinal surface topography with an imaging modality that has lacked prior objective assessment.

  17. A Geospatial Semantic Enrichment and Query Service for Geotagged Photographs

    Science.gov (United States)

    Ennis, Andrew; Nugent, Chris; Morrow, Philip; Chen, Liming; Ioannidis, George; Stan, Alexandru; Rachev, Preslav

    2015-01-01

    With the increasing abundance of technologies and smart devices, equipped with a multitude of sensors for sensing the environment around them, information creation and consumption has now become effortless. This, in particular, is the case for photographs with vast amounts being created and shared every day. For example, at the time of this writing, Instagram users upload 70 million photographs a day. Nevertheless, it still remains a challenge to discover the “right” information for the appropriate purpose. This paper describes an approach to create semantic geospatial metadata for photographs, which can facilitate photograph search and discovery. To achieve this we have developed and implemented a semantic geospatial data model by which a photograph can be enrich with geospatial metadata extracted from several geospatial data sources based on the raw low-level geo-metadata from a smartphone photograph. We present the details of our method and implementation for searching and querying the semantic geospatial metadata repository to enable a user or third party system to find the information they are looking for. PMID:26205265

  18. Determination of Sunset Yellow and Tartrazine in Food Samples by Combining Ionic Liquid-Based Aqueous Two-Phase System with High Performance Liquid Chromatography

    Science.gov (United States)

    Sha, Ou; Zhu, Xiashi; Feng, Yanli; Ma, Weixing

    2014-01-01

    We proposed a simple and effective method, by coupling ionic liquid-based aqueous two-phase systems (IL-ATPSs) with high performance liquid chromatography (HPLC), for the analysis of determining tartrazine and sunset yellow in food samples. Under the optimized conditions, IL-ATPSs generated an extraction efficiency of 99% for both analytes, which could then be directly analyzed by HPLC without further treatment. Calibration plots were linear in the range of 0.01–50.0 μg/mL for both Ta and SY. The limits of detection were 5.2 ng/mL for Ta and 6.9 ng/mL for SY. This method proves successful for the separation/analysis of tartrazine and sunset yellow in soft drink sample, candy sample, and instant powder drink and leads to consistent results as obtained from the Chinese national standard method. PMID:25538857

  19. Determination of Sunset Yellow and Tartrazine in Food Samples by Combining Ionic Liquid-Based Aqueous Two-Phase System with High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Ou Sha

    2014-01-01

    Full Text Available We proposed a simple and effective method, by coupling ionic liquid-based aqueous two-phase systems (IL-ATPSs with high performance liquid chromatography (HPLC, for the analysis of determining tartrazine and sunset yellow in food samples. Under the optimized conditions, IL-ATPSs generated an extraction efficiency of 99% for both analytes, which could then be directly analyzed by HPLC without further treatment. Calibration plots were linear in the range of 0.01–50.0 μg/mL for both Ta and SY. The limits of detection were 5.2 ng/mL for Ta and 6.9 ng/mL for SY. This method proves successful for the separation/analysis of tartrazine and sunset yellow in soft drink sample, candy sample, and instant powder drink and leads to consistent results as obtained from the Chinese national standard method.

  20. Determination of sunset yellow and tartrazine in food samples by combining ionic liquid-based aqueous two-phase system with high performance liquid chromatography.

    Science.gov (United States)

    Sha, Ou; Zhu, Xiashi; Feng, Yanli; Ma, Weixing

    2014-01-01

    We proposed a simple and effective method, by coupling ionic liquid-based aqueous two-phase systems (IL-ATPSs) with high performance liquid chromatography (HPLC), for the analysis of determining tartrazine and sunset yellow in food samples. Under the optimized conditions, IL-ATPSs generated an extraction efficiency of 99% for both analytes, which could then be directly analyzed by HPLC without further treatment. Calibration plots were linear in the range of 0.01-50.0 μg/mL for both Ta and SY. The limits of detection were 5.2 ng/mL for Ta and 6.9 ng/mL for SY. This method proves successful for the separation/analysis of tartrazine and sunset yellow in soft drink sample, candy sample, and instant powder drink and leads to consistent results as obtained from the Chinese national standard method.

  1. A programming system for bubble chamber photographs measuring tables on-line to a computer

    International Nuclear Information System (INIS)

    Miche, Roger.

    1975-06-01

    A programming system available on an industrial computer, type PDP 15/20, performing the exploitation of bubble chamber pictures with the projection tables on line to the computer was developed. This system must suit the particular conditions met in the analysis of photographs from different bubble chambers, the different stage for dealing with the views (scanning, premeasurement, measurement) adapting to different strategies in the handling of measurements. The exploitation of photographs takes place in a conversational mode to which a concrete form is given by sending messages to the operators at the tables and by receiving coded answers. In this framework, the aims of the operating system are: to guide the operator work at the tables while allowing them to interrupt the normal sequence of events, to carry out some elementary logical checks, to write on magnetic tape the checked data with the appropriate labels as required [fr

  2. Possibilities to improve sensitivity and rendering of detail of streamer chamber track photographs

    Energy Technology Data Exchange (ETDEWEB)

    Baehr, J

    1975-01-01

    Streamer chambers are increasingly used as effective particle detectors in the field of experimental elementary particle physics. The photographic recording of high energy events in streamer chambers is limited by performance of current photographic silver-halide layers. Similar limiting problems occur in other fields as well, e.g., in astronomy, x-ray medicine and photogrammetry; therefore methods have been developed to increase sensitivity and improve the information transfer of the emulsion. In this paper these methods have been classified and summarized under the aspect of their application to streamer image recording. Proposals for further investigations are given. Especially the applicability of these methods, their possibility of combination to large film lengths should be investigated The detective quantum efficiency (DQE) is proposed as criterion to estimate and compare the different methods.

  3. Development of ultra high speed photographic system using high repetition rate visible laser

    International Nuclear Information System (INIS)

    Lee, Jong Min; Cha, Byung Hun; Kim, Sung Ho; Kim, Jung Bog; Lim, Chang Hwan; Cha, Hyung Ki; Song, Kyu Seok; Lee, Byung Deok; Rhi, Jong Hoon; Baik, Dae Hyun; Han, Jae Min; Rho, Si Pyo; Lee, Byung Cheol; Jeong, Do Yung; Choi, An Seong; Jeong, Chan Ik; Park, Dae Ung; Jeong, Sung Min; Lee, Sang Kil; Kim, Heon Jun; Jang, Rae gak; Jo, Do Hun; Park, Min Young

    1992-12-01

    The goal of this project is to develop and commercialize a high speed photographic system equipped with a high repetition rate visible laser. The developed system provides the characteristics of high time resolution and large number of frames. The system consists of 10 W air cooled CVL or a 30 W water cooled CVL, a rotating drum-type high speed camera with the framing rate of 35,000 fps, and a automatic control device. The system has the performance of 10 nsec time resolution, 35,000 fps framing rate, and 250 picture frames. The high speed photographic systems are widely applied to the fields such as high-efficient engine development, high-speed vibration analysis, shock wave propagation study, flow visualization analysis, weapon development, etc. (Author)

  4. Optimal wavelet transform for the detection of microaneurysms in retina photographs.

    Science.gov (United States)

    Quellec, Gwénolé; Lamard, Mathieu; Josselin, Pierre Marie; Cazuguel, Guy; Cochener, Béatrice; Roux, Christian

    2008-09-01

    In this paper, we propose an automatic method to detect microaneurysms in retina photographs. Microaneurysms are the most frequent and usually the first lesions to appear as a consequence of diabetic retinopathy. So, their detection is necessary for both screening the pathology and follow up (progression measurement). Automating this task, which is currently performed manually, would bring more objectivity and reproducibility. We propose to detect them by locally matching a lesion template in subbands of wavelet transformed images. To improve the method performance, we have searched for the best adapted wavelet within the lifting scheme framework. The optimization process is based on a genetic algorithm followed by Powell's direction set descent. Results are evaluated on 120 retinal images analyzed by an expert and the optimal wavelet is compared to different conventional mother wavelets. These images are of three different modalities: there are color photographs, green filtered photographs, and angiographs. Depending on the imaging modality, microaneurysms were detected with a sensitivity of respectively 89.62%, 90.24%, and 93.74% and a positive predictive value of respectively 89.50%, 89.75%, and 91.67%, which is better than previously published methods.

  5. Application of dispersive liquid-liquid microextraction for the preconcentration of eight parabens in real samples and their determination by high-performance liquid chromatography.

    Science.gov (United States)

    Shen, Xiong; Liang, Jian; Zheng, Luxia; Lv, Qianzhou; Wang, Hong

    2017-11-01

    A simple and sensitive method for the simultaneous determination of eight parabens in human plasma and urine samples was developed. The samples were preconcentrated using dispersive liquid-liquid microextraction based on the solidification of floating organic drops and determined by high-performance liquid chromatography with ultraviolet detection. The influence of variables affecting the extraction efficiency was investigated and optimized using Placket-Burman design and Box-Behnken design. The optimized values were: 58 μL of 1-decanol (as extraction solvent), 0.65 mL methanol (as disperser solvent), 1.5% w/v NaCl in 5.0 mL of sample solution, pH 10.6, and 4.0 min centrifugation at 4000 rpm. The extract was injected into the high-performance liquid chromatography system for analysis. Under the optimum conditions, the linear ranges for eight parabens in plasma and urine were 1.0-1000 ng/mL, with correlation coefficients above 0.994. The limit of detection was 0.2-0.4 and 0.1-0.4 ng/mL for plasma and urine samples, respectively. Relative recoveries were between 80.3 and 110.7%, while relative standard deviations were less than 5.4%. Finally, the method was applied to analyze the parabens in 98 patients of primary breast cancer. Results showed that parabens existed widely, at least one paraben detected in 96.9% (95/98) of plasma samples and 98.0% (96/98) of urine samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Application of ultrasound-assisted emulsification microextraction for simultaneous determination of aminophenol isomers in human urine, hair dye, and water samples using high-performance liquid chromatography.

    Science.gov (United States)

    Asghari, Alireza; Fazl-Karimi, Hamidreza; Barfi, Behruz; Rajabi, Maryam; Daneshfar, Ali

    2014-08-01

    Aminophenol isomers (2-, 3-, and 4-aminophenols) are typically classified as industrial pollutants with genotoxic and mutagenic effects due to their easy penetration through the skin and membranes of human, animals, and plants. In the present study, a simple and efficient ultrasound-assisted emulsification microextraction procedure coupled with high-performance liquid chromatography with ultraviolet detector was developed for preconcentration and determination of these compounds in human fluid and environmental water samples. Effective parameters (such as type and volume of extraction solvent, pH and ionic strength of sample, and ultrasonication and centrifuging time) were investigated and optimized. Under optimum conditions (including sample volume: 5 mL; extraction solvent: chloroform, 80 µL; pH: 6.5; without salt addition; ultrasonication: 3.5 min; and centrifuging time: 3 min, 5000 rpm min(-1)), the enrichment factors and limits of detection were ranged from 42 to 51 and 0.028 to 0.112 µg mL(-1), respectively. Once optimized, analytical performance of the method was studied in terms of linearity (0.085-157 µg mL(-1), r (2) > 0.998), accuracy (recovery = 88.6- 101.7%), and precision (repeatability: intraday precision water samples. © The Author(s) 2014.

  7. Reversed-phase single drop microextraction followed by high-performance liquid chromatography with fluorescence detection for the quantification of synthetic phenolic antioxidants in edible oil samples.

    Science.gov (United States)

    Farajmand, Bahman; Esteki, Mahnaz; Koohpour, Elham; Salmani, Vahid

    2017-04-01

    The reversed-phase mode of single drop microextraction has been used as a preparation method for the extraction of some phenolic antioxidants from edible oil samples. Butylated hydroxyl anisole, tert-butylhydroquinone and butylated hydroxytoluene were employed as target compounds for this study. High-performance liquid chromatography followed by fluorescence detection was applied for final determination of target compounds. The most interesting feature of this study is the application of a disposable insulin syringe with some modification for microextraction procedure that efficiently improved the volume and stability of the solvent microdrop. Different parameters such as the type and volume of solvent, sample stirring rate, extraction temperature, and time were investigated and optimized. Analytical performances of the method were evaluated under optimized conditions. Under the optimal conditions, relative standard deviations were between 4.4 and 10.2%. Linear dynamic ranges were 20-10 000 to 2-1000 μg/g (depending on the analytes). Detection limits were 5-670 ng/g. Finally, the proposed method was successfully used for quantification of the antioxidants in some edible oil samples prepared from market. Relative recoveries were achieved from 88 to 111%. The proposed method had a simplicity of operation, low cost, and successful application for real samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Molecularly imprinted polymer cartridges coupled on-line with high performance liquid chromatography for simple and rapid analysis of dextromethorphan in human plasma samples.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Javanbakht, Mehran; Akbari-Adergani, Behrouz

    2011-04-01

    In this paper, a novel method is described for automated determination of dextromethorphan in biological fluids using molecularly imprinted solid-phase extraction (MISPE) as a sample clean-up technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and dextromethorphan as template molecule. These imprinted polymers were used as solid-phase extraction sorbent for the extraction of dextromethorphan from human plasma samples. Various parameters affecting the extraction efficiency of the MIP cartridges were evaluated. The high selectivity of the sorbent coupled to the high performance liquid chromatographic system permitted a simple and rapid analysis of this drug in plasma samples with limits of detection (LOD) and quantification (LOQ) of 0.12 ng/mL and 0.35 ng/mL, respectively. The MIP selectivity was evaluated by analyzing of the dextromethorphan in presence of several substances with similar molecular structures and properties. Results from the HPLC analyses showed that the recoveries of dextromethorphan using MIP cartridges from human plasma samples in the range of 1-50 ng/mL were higher than 87%. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Performance testing of a semi-automatic card punch system, using direct STR profiling of DNA from blood samples on FTA™ cards.

    Science.gov (United States)

    Ogden, Samantha J; Horton, Jeffrey K; Stubbs, Simon L; Tatnell, Peter J

    2015-01-01

    The 1.2 mm Electric Coring Tool (e-Core™) was developed to increase the throughput of FTA(™) sample collection cards used during forensic workflows and is similar to a 1.2 mm Harris manual micro-punch for sampling dried blood spots. Direct short tandem repeat (STR) DNA profiling was used to compare samples taken by the e-Core tool with those taken by the manual micro-punch. The performance of the e-Core device was evaluated using a commercially available PowerPlex™ 18D STR System. In addition, an analysis was performed that investigated the potential carryover of DNA via the e-Core punch from one FTA disc to another. This contamination study was carried out using Applied Biosystems AmpflSTR™ Identifiler™ Direct PCR Amplification kits. The e-Core instrument does not contaminate FTA discs when a cleaning punch is used following excision of discs containing samples and generates STR profiles that are comparable to those generated by the manual micro-punch. © 2014 American Academy of Forensic Sciences.

  10. Um estudo dos relatos afetivos subjetivos a estímulos do International Affective Picture System em uma amostra geriátrica brasileira Subjective affective ratings to photographic stimuli of the International Affective Picture System in a Brazilian elderly sample

    Directory of Open Access Journals (Sweden)

    Weyler Galvão Porto

    2008-08-01

    Manikin scale scores. METHOD: Forty-eight clinically and cognitively capable elderly volunteer subjects from the Third Age Open University evaluated 71 randomly chosen images of the International Affective Picture System in terms of arousal and affective valence. RESULTS: For the elderly, the greater the arousal, the smaller the pleasure resulting in a strong negative correlation (r = 0.93 observed between arousal and negative valence. A comparison with another similar normative experiment performed in young Brazilian and American individuals showed a possible cultural difference in subjective reports of emotional stimuli. CONCLUSIONS: This investigation indicates that there may be a difference between elderly and young individuals when affective reports of arousal are studied. A normalization of the International Affective Picture System for the elderly in a larger sample, representative of the population, might be useful to address this issue.

  11. STS-98 Onboard Photograph-U.S. Laboratory, Destiny

    Science.gov (United States)

    2001-01-01

    The International Space Station (ISS), with the newly installed U.S. Laboratory, Destiny, is backdropped over clouds, water and land in South America. South Central Chile shows up at the bottom of the photograph. Just below the Destiny, the Chacao Charnel separates the large island of Chile from the mainland and connects the Gulf of Coronado on the Pacific side with the Gulf of Ancud, southwest of the city of Puerto Montt. The American-made Destiny module is the cornerstone for space-based research aboard the orbiting platform and the centerpiece of the ISS, where unprecedented science experiments will be performed in the near-zero gravity of space. Destiny will also serve as the command and control center for the ISS. The aluminum module is 8.5-meters (28-feet) long and 4.3-meters (14-feet) in diameter. The laboratory consists of three cylindrical sections and two endcones with hatches that will be mated to other station components. A 50.9-centimeter (20-inch-) diameter window is located on one side of the center module segment. This pressurized module is designed to accommodate pressurized payloads. It has a capacity of 24 rack locations. Payload racks will occupy 15 locations especially designed to support experiments. The Destiny module was built by the Boeing Company under the direction of the Marshall Space Flight Center.

  12. 32 CFR 705.11 - Supplying photographs and services to other than Navy and Marine Corps.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Supplying photographs and services to other than....11 Supplying photographs and services to other than Navy and Marine Corps. (a) To avoid competition with civilian photographic organizations, naval aircraft will not be used to take photographs for, nor...

  13. 46 CFR 386.17 - Photographs for news, advertising, or commercial purposes.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Photographs for news, advertising, or commercial... § 386.17 Photographs for news, advertising, or commercial purposes. Such photographs for news... Court Order or rule prohibits, photographs for news purposes may be taken in entrances, lobbies, foyers...

  14. 32 CFR 228.11 - Restrictions on the taking of photographs.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false Restrictions on the taking of photographs. 228... photographs. In order to protect the security of the Agency's facilities, photographs may be taken on... photographs includes the use of television cameras, video taping equipment, and still or motion picture...

  15. Evaluation of an online peer fundus photograph matching program in teaching direct ophthalmoscopy to medical students.

    Science.gov (United States)

    Kwok, Jason; Liao, Walter; Baxter, Stephanie

    2017-10-01

    Direct ophthalmoscopy is an important clinical skill that is often poorly performed by medical professionals and students. This is attributable to a declining emphasis on ophthalmology in medical school. We present and evaluate a self-directed approach of teaching ophthalmoscopy to medical students that is suitable for the current medical curriculum. Prospective medical education trial. Ninety-five second-year medical students at Queen's University: 32 in the experimental group and 63 in the control group. The experimental group consisted of medical students who practised ophthalmoscopy with one another using an online peer fundus photograph matching exercise created by the Department of Ophthalmology at Queen's University. To use the program, students first examined a peer with an ophthalmoscope and then selected an online photograph of a fundus corresponding to that of the examinee. The program notifies students if a correct selection is made. To encourage use of the program, students participated in a 2-week ophthalmoscopy competition during their ophthalmology rotation. The control group consisted of students who did not participate in the learning exercise. On assessment at the end of the ophthalmology rotation, the experimental group (n = 32) was more accurate in matching fundus photographs compared with the control group (n = 63) (p = 0.02). Participants were faster at performing ophthalmoscopy at the end of the learning exercise (p peer fundus photographs in a self-directed manner appeared to increase the skill and confidence of medical students in ophthalmoscopy. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  16. Reading and writing direction effects on the aesthetic appreciation of photographs.

    Science.gov (United States)

    Chahboun, Sobh; Flumini, Andrea; Pérez González, Carmen; McManus, I Chris; Santiago, Julio

    2017-05-01

    Does reading and writing direction (RWD) influence the aesthetic appreciation of photography? Pérez González showed that nineteenth-century Iranian and Spanish professional photographers manifest lateral biases linked to RWD in their compositions. The present study aimed to test whether a population sample showed similar biases. Photographs with left-to-right (L-R) and right-to-left (R-L) directionality were selected from Pérez González's collections and presented in both original and mirror-reversed forms to Spanish (L-R readers) and Moroccan (R-L readers) participants. In Experiment 1, participants rated each picture for its aesthetic pleasingness. The results showed neither effects of lateral organization nor interactions with RWD. In Experiment 2, each picture and its mirror version were presented together and participants chose the one they liked better. Spaniards preferred rightward versions and Moroccans preferred leftward versions. RWD therefore affects aesthetic impressions of photography in our participants when people pay attention to the lateral spatial dimension of pictures. The observed directional aesthetic preferences were not sensitive to the sex of the model in the photographs, failing to support expectations from the hypotheses of emotionality and agency. Preferences were attributable to the interaction between general scanning strategies and scanning habits linked to RWD.

  17. Performance on cognitive tests, instrumental activities of daily living and depressive symptoms of a community-based sample of elderly adults in Rio de Janeiro, Brazil

    Science.gov (United States)

    Lima, Christina Martins Borges; Alves, Heloisa Veiga Dias; Mograbi, Daniel Correa; Pereira, Flávia Furtado; Fernandez, Jesus Landeira; Charchat-Fichman, Helenice

    2017-01-01

    Objective To describe the performance on basic cognitive tasks, instrumental activities of daily living, and depressive symptoms of a community-based sample of elderly adults in Rio de Janeiro (Brazil) who participated in multiple physical, social, and cognitive activities at government-run community centers. Methods A total of 264 educated older adults (> 60 years of age of both genders) were evaluated by the Brief Cognitive Screening Battery (BCSB), Lawton's and Pfeffer's activities of daily living indexes, and the Geriatric Depressive Scale (GDS). Results The mean age of the sample was 75.7 years. The participants had a mean of 9.3 years of formal education. With the exception of the Clock Drawing Test (CDT), mean scores on the cognitive tests were consistent with the values in the literature. Only 6.4% of the sample had some kind of dependence for activities of daily living. The results of the Geriatric Depression Scale (GDS-15) indicated mild symptoms of depression in 16.8% of the sample Conclusion This study provided important demographic, cognitive, and functional characteristics of a specific community-based sample of elderly adults in Rio de Janeiro, Brazil. PMID:29213494

  18. Performance on cognitive tests, instrumental activities of daily living and depressive symptoms of a community-based sample of elderly adults in Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    Christina Martins Borges Lima

    Full Text Available ABSTRACT Objective: To describe the performance on basic cognitive tasks, instrumental activities of daily living, and depressive symptoms of a community-based sample of elderly adults in Rio de Janeiro (Brazil who participated in multiple physical, social, and cognitive activities at government-run community centers. Methods: A total of 264 educated older adults (> 60 years of age of both genders were evaluated by the Brief Cognitive Screening Battery (BCSB, Lawton's and Pfeffer's activities of daily living indexes, and the Geriatric Depressive Scale (GDS . Results: The mean age of the sample was 75.7 years. The participants had a mean of 9.3 years of formal education. With the exception of the Clock Drawing Test (CDT, mean scores on the cognitive tests were consistent with the values in the literature. Only 6.4% of the sample had some kind of dependence for activities of daily living. The results of the Geriatric Depression Scale (GDS-15 indicated mild symptoms of depression in 16.8% of the sample. Conclusion: This study provided important demographic, cognitive, and functional characteristics of a specific community-based sample of elderly adults in Rio de Janeiro, Brazil.

  19. Remote diagnosis of traumatic dental injuries using digital photographs captured via a mobile phone.

    Science.gov (United States)

    de Almeida Geraldino, Rogério; Rezende, Liliana Vicente Melo de Lucas; da-Silva, Cibele Queiroz; Almeida, Júlio César Franco

    2017-10-01

    Intra-oral photographs have been aided diagnosis of several pathologies in teledentistry. Mobile phone cameras may produce high-quality photographs, presenting itself as a viable tool for remote diagnosis of traumatic dental injuries. To evaluate the levels of interexaminer agreement in cases of traumatic dental injuries when comparing diagnoses conducted in person and remotely. The sample included 40 patients with 73 traumatized teeth, and a total of 90 diagnoses, who had presented to two dental clinics, one private, and the other public, in Brazil's Federal District. The dental history and clinical examination data were registered in electronic forms, and digital photographs were captured with a mobile phone camera and uploaded to a cloud drive. Six remote examiners formulated their diagnoses based solely on photographic analysis. Thereafter, they were provided with additional clinical data and asked to provide a second round of diagnoses. These diagnoses were compared to those conducted in person, which were considered the gold standard. The data were analyzed with Gwet's AC1 interexaminers' measure to evaluate the agreement between the in-surgery and remote diagnoses. The levels of interexaminer agreement between the in-surgery and remote diagnoses formulated exclusively with images were 0.83 or higher (95% confidence interval: 0.73-0.91), and 0.93 or higher (95% confidence interval: 0.88-0.97), when clinical information was available. The precision of the remote diagnoses was comparable to the diagnoses conducted in person. The levels of interexaminer agreement were higher when clinical data were included with the images. Mobile phones may be an effective tool for capturing images that assist in the remote diagnosis of traumatic dental injuries. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Socioeconomic, emotional, and physical execution variables as predictors of cognitive performance in a Spanish sample of middle-aged and older community-dwelling participants.

    Science.gov (United States)

    González, Mari Feli; Facal, David; Juncos-Rabadán, Onésimo; Yanguas, Javier

    2017-10-01

    Cognitive performance is not easily predicted, since different variables play an important role in the manifestation of age-related declines. The objective of this study is to analyze the predictors of cognitive performance in a Spanish sample over 50 years from a multidimensional perspective, including socioeconomic, affective, and physical variables. Some of them are well-known predictors of cognition and others are emergent variables in the study of cognition. The total sample, drawn from the "Longitudinal Study Aging in Spain (ELES)" project, consisted of 832 individuals without signs of cognitive impairment. Cognitive function was measured with tests evaluating episodic and working memory, visuomotor speed, fluency, and naming. Thirteen independent variables were selected as predictors belonging to socioeconomic, emotional, and physical execution areas. Multiple linear regressions, following the enter method, were calculated for each age group in order to study the influence of these variables in cognitive performance. Education is the variable which best predicts cognitive performance in the 50-59, 60-69, and 70-79 years old groups. In the 80+ group, the best predictor is objective economic status and education does not enter in the model. Age-related decline can be modified by the influence of educational and socioeconomic variables. In this context, it is relevant to take into account how easy is to modify certain variables, compared to others which depend on each person's life course.

  1. Lewis M. Rutherfurd and the First Photograph of Solar Granulation

    Science.gov (United States)

    Harvey, J. W.; Briggs, John W.; Prosser, Sian

    2017-08-01

    A major astronomical controversy of the mid-19th century was discordant descriptions of the small scale structure of the solar surface. Visual observers contradicted each other by describing the surface as consisting of “corrugations”, “willow leaves”, “rice grains”, “cumuli”, “thatch”, “granules”, etc. Early photographs of the solar surface were not good enough to settle the controversy. The French astronomer Jules Janssen is credited with the first 1876 photographs that clearly showed what we now call solar granulation (1876, CRAS 82, 1363). Upon seeing these images, New Yorker Lewis M. Rutherfurd (1878, MNRAS 38, 410) praised the high quality of Janssen’s images but asserted that he had also photographed granulation as early as 1871 using collodion wet plates. He sent copies of his best photograph to the Royal Astronomical Society to support his assertion. Curious about his claim, Briggs and Harvey set up Rutherfurd’s 13-inch achromatic refractor on Kitt Peak and found that it easily showed well-resolved solar granulation, so his claim might well have been justified. But without his plates we could not confirm the claim. For 140 years the copies of Rutherfurd’s best solar photograph remained in the archives of the Royal Astronomical Society and were recently discovered by Prosser (RAS Photographs A3/001B and A3/002). By coincidence a few days later, Briggs found the original August 11, 1871 plate. Despite poor condition these photographs show solar granulation. There are at least two other possible early claimants (Reade; Vogel) but their plates are almost certainly lost. Rutherfurd was a master of astronomical instrumentation and photography. He was reticent about his work, letting results speak for themselves, so it is satisfying to find that he was justified in making his claim of priority.

  2. Study of face pleasantness using facial analysis in standardized frontal photographs

    Directory of Open Access Journals (Sweden)

    Imara de Almeida Castro Morosini

    2012-10-01

    Full Text Available OBJECTIVE: The purpose of this research was to check if the numeric facial analysis can determine facial attractiveness. METHOD: The sample consisted of frontal and lateral standard facial photographs, in natural head position, of 85 Brazilian Caucasian women, without facial plastic surgery report. The sample mean age was 23 years and 9 months. A group of 5 orthodontists, 5 layman and 5 plastic artists classified the photographs according to their own attractiveness graduation in: pleasant, acceptable and not pleasant. The numeric facial analysis was then performed using a computerized method. Linear, proportional and angular measurements were compared among groups. RESULTS: According subjective analysis the sample was consisted of 18.8% of pleasant, 70.6% of acceptable and 10.6% of not pleasant. In most measurements there were no differences among groups. Just in three of them significant statistical difference was observed and in two of them the comparison value was within decision limit. All the differences found were related to the lower third of the face and to facial pattern. CONCLUSION: On the present research, the numeric facial analysis, by itself, was not capable of detecting facial attractiveness, considering that beauty judgment seems to be very personal.OBJETIVO: esse estudo foi desenvolvido com o propósito de verificar se a análise facial numérica realizada em fotografias frontais é sensível em detectar a atratividade da face. MÉTODOS: a amostra foi composta por fotografias faciais padronizadas, frontais e laterais, em posição natural da cabeça, de 85 mulheres brasileiras, leucodermas, com idades entre 18 e 30 anos, sem histórico de cirurgia plástica facial. A idade média da amostra foi de 23 anos e 9 meses. As fotografias foram classificadas de acordo com o grau de atratividade da face por uma banca composta de cinco especialistas em Ortodontia, cinco leigos e cinco artistas plásticos. A partir dessa classifica

  3. Impact of partial pressure of oxygen in blood samples on the performance of systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Schmid, Christina; Baumstark, Annette; Pleus, Stefan; Haug, Cornelia; Tesar, Martina; Freckmann, Guido

    2014-03-01

    The partial pressure of oxygen (pO2) in blood samples can affect glucose measurements with oxygen-sensitive systems. In this study, we assessed the influence of different pO2 levels on blood glucose (BG) measurements with five glucose oxidase (GOD) systems and one glucose dehydrogenase (GDH) system. All selected GOD systems were indicated by the manufacturers to be sensitive to increased oxygen content of the blood sample. Venous blood samples of 16 subjects (eight women, eight men; mean age, 52 years; three with type 1 diabetes, four with type 2 diabetes, and nine without diabetes) were collected. Aliquots of each sample were adjusted to the following pO2 values: ≤45 mm Hg, approximately 70 mm Hg, and ≥150 mm Hg. For each system, five consecutive measurements on each sample were performed using the same test strip lot. Relative differences between the mean BG value at a pO2 level of approximately 70 mm Hg, which was considered to be similar to pO2 values in capillary blood samples, and the mean BG value at pO2 levels ≤45 mm Hg and ≥150 mm Hg were calculated. The GOD systems showed mean relative differences between 11.8% and 44.5% at pO2 values ≤45 mm Hg and between -14.6% and -21.2% at pO2 values ≥150 mm Hg. For the GDH system, the mean relative differences were -0.3% and -0.2% at pO2 values ≤45 mm Hg and ≥150 mm Hg, respectively. The magnitude of the pO2 impact on BG measurements seems to vary among the tested oxygen-sensitive GOD systems. The pO2 range in which oxygen-sensitive systems operate well should be provided in the product information.

  4. Determination of benzothiazole and benzotriazole derivates in tire and clothing textile samples by high performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Avagyan, Rozanna; Sadiktsis, Ioannis; Thorsén, Gunnar; Östman, Conny; Westerholm, Roger

    2013-09-13

    A high performance liquid chromatography-tandem mass spectrometry method utilizing electrospray ionization in positive and negative mode has been developed for the separation and detection of benzothiazole and benzotriazole derivates. Ultra-sonication assisted solvent extraction of these compounds has also been developed and the overall method demonstrated on a selected clothing textile and an automobile tire sample. Matrix effects and extraction recoveries, as well as linearity and limits of detection have been evaluated. The calibration curves spanned over more than two orders of magnitude with coefficients of correlation R(2)>0.99 and the limits of detection and the limits of quantification were in the range 1.7-58pg injected and 18-140pg/g, respectively. The extraction recoveries ranged between 69% and 102% and the matrix effects between 75% and 101%. Benzothiazole and benzotriazole derivates were determined in the textile sample and benzothiazole derivatives determined in the tire sample with good analytical performance. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Construction of tomographic head model using sectioned photographic images of cadaver

    International Nuclear Information System (INIS)

    Lee, Choon Sik; Lee, Jai Ki; Park, Jin Seo; Chung, Min Suk

    2004-01-01

    Tomographic models are currently the most complete, developed and realistic models of the human anatomy. They have been used to estimate organ doses for diagnostic radiation examination and radiotherapy treatment planning, and radiation protection. The quality of original anatomic images is a key factor to build a quality tomographic model. Computed tomography (CT) and magnetic resonance imaging (MRI) scan, from which most of current tomographic models are constructed, have their inherent shortcomings. In this study, a tomographic model of Korean adult male head was constructed by using serially sectioned photographs of cadaver. The cadaver was embedded, frozen, serially sectioned and photographed by high resolution digital camera at 0.2 mm interval. The contours of organs and tissues in photographs were segmented by several trained anatomists. The 120 segmented images of head at 2mm interval were converted into binary files and ported into Monte Carlo code to perform an example calculation of organ dose. Whole body tomographic model will be constructed by using the procedure developed in this study

  6. Psycholinguistic norms for action photographs in French and their relationships with spoken and written latencies.

    Science.gov (United States)

    Bonin, Patrick; Boyer, Bruno; Méot, Alain; Fayol, Michel; Droit, Sylvie

    2004-02-01

    A set of 142 photographs of actions (taken from Fiez & Tranel, 1997) was standardized in French on name agreement, image agreement, conceptual familiarity, visual complexity, imageability, age of acquisition, and duration of the depicted actions. Objective word frequency measures were provided for the infinitive modal forms of the verbs and for the cumulative frequency of the verbal forms associated with the photographs. Statistics on the variables collected for action items were provided and compared with the statistics on the same variables collected for object items. The relationships between these variables were analyzed, and certain comparisons between the current database and other similar published databases of pictures of actions are reported. Spoken and written naming latencies were also collected for the photographs of actions, and multiple regression analyses revealed that name agreement, image agreement, and age of acquisition are the major determinants of action naming speed. Finally, certain analyses were performed to compare object and action naming times. The norms and the spoken and written naming latencies corresponding to the pictures are available on the Internet (http://www.psy.univ-bpclermont.fr/~pbonin/pbonin-eng.html) and should be of great use to researchers interested in the processing of actions.

  7. Photographic Standards for Patients With Facial Palsy and Recommendations by Members of the Sir Charles Bell Society.

    Science.gov (United States)

    Santosa, Katherine B; Fattah, Adel; Gavilán, Javier; Hadlock, Tessa A; Snyder-Warwick, Alison K

    2017-07-01

    There is no widely accepted assessment tool or common language used by clinicians caring for patients with facial palsy, making exchange of information challenging. Standardized photography may represent such a language and is imperative for precise exchange of information and comparison of outcomes in this special patient population. To review the literature to evaluate the use of facial photography in the management of patients with facial palsy and to examine the use of photography in documenting facial nerve function among members of the Sir Charles Bell Society-a group of medical professionals dedicated to care of patients with facial palsy. A literature search was performed to review photographic standards in patients with facial palsy. In addition, a cross-sectional survey of members of the Sir Charles Bell Society was conducted to examine use of medical photography in documenting facial nerve function. The literature search and analysis was performed in August and September 2015, and the survey was conducted in August and September 2013. The literature review searched EMBASE, CINAHL, and MEDLINE databases from inception of each database through September 2015. Additional studies were identified by scanning references from relevant studies. Only English-language articles were eligible for inclusion. Articles that discussed patients with facial palsy and outlined photographic guidelines for this patient population were included in the study. The survey was disseminated to the Sir Charles Bell Society members in electronic form. It consisted of 10 questions related to facial grading scales, patient-reported outcome measures, other psychological assessment tools, and photographic and videographic recordings. In total, 393 articles were identified in the literature search, 7 of which fit the inclusion criteria. Six of the 7 articles discussed or proposed views specific to patients with facial palsy. However, none of the articles specifically focused on

  8. Validation of Performance of the Gen-Probe Human Immunodeficiency Virus Type 1 Viral Load Assay with Genital Swabs and Breast Milk Samples

    Science.gov (United States)

    DeVange Panteleeff, Dana; Emery, Sandra; Richardson, Barbra A.; Rousseau, Christine; Benki, Sarah; Bodrug, Sharon; Kreiss, Joan K.; Overbaugh, Julie

    2002-01-01

    Human immunodeficiency type 1 (HIV-1) continues to spread at an alarming rate. The virus may be transmitted through blood, genital secretions, and breast milk, and higher levels of systemic virus in the index case, as measured by plasma RNA viral load, have been shown to correlate with increased risk of transmitting HIV-1 both vertically and sexually. Less is known about the correlation between transmission and HIV-1 levels in breast milk or genital secretions, in part because reliable quantitative assays to detect HIV-1 in these fluids are not available. Here we show that the Gen-Probe HIV-1 viral load assay can be used to accurately quantify viral load in expressed breast milk and in cervical and vaginal samples collected on swabs. Virus could be quantified from breast milk and swab samples spiked with known amounts of virus, including HIV-1 subtypes A, C, and D. As few as 10 copies of HIV-1 RNA could be detected above background threshold levels in ≥77% of assays performed with spiked breast milk supernatants and mock swabs. In genital swab samples from HIV-1-infected women, similar levels of HIV-1 RNA were consistently detected in duplicate swabs taken from the same woman on the same clinic visit, suggesting that the RNA values from a single swab sample can be used to measure genital viral load. PMID:12409354

  9. Screening and identification of antioxidants in biological samples using high-performance liquid chromatography-mass spectrometry and its application on Salacca edulis Reinw.

    Science.gov (United States)

    Shui, Guanghou; Leong, Lai Peng

    2005-02-23

    In this study, a new approach was developed for screening and identifying antioxidants in biological samples. The approach was based on significant decreases of the intensities of ion peaks obtained from high-performance liquid chromatography (HPLC) coupled with mass spectrometry (MS) upon reaction with 2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) free radicals. HPLC-MS/MS was further applied to elucidate structures of antioxidant peaks characterized in a spiking test. The new approach could also be used to monitor the reactivity of antioxidants in biological sample with free radicals. The approach was successfully applied to the identification of antioxidants in salak (Salacca edulis Reinw), a tropical fruit that is reported to be a very good source of natural antioxidants, but it was still not clear which compounds were responsible for its antioxidant property. The antioxidants in salak were identified to be chlorogenic acid, (-)-epicatechin, and singly linked proanthocyanidins that mainly existed as dimers through hexamers of catechin or epicatechin. In salak, chlorogenic acid was identified to be an antioxidant of the slow reaction type as it reacted with free radicals much more slowly than either (-)-epicatechin or proanthocyanidins. The new approach was proved to be useful for the characterization and identification of antioxidants in biological samples as a mass detector combined with an HPLC separation system not only serves as an ideal tool to monitor free radical active components but also provides their possible chemical structures in a biological sample.

  10. Preconcentration and determination of ceftazidime in real samples using dispersive liquid-liquid microextraction and high-performance liquid chromatography with the aid of experimental design.

    Science.gov (United States)

    Razmi, Rasoul; Shahpari, Behrouz; Pourbasheer, Eslam; Boustanifar, Mohammad Hasan; Azari, Zhila; Ebadi, Amin

    2016-11-01

    A rapid and simple method for the extraction and preconcentration of ceftazidime in aqueous samples has been developed using dispersive liquid-liquid microextraction followed by high-performance liquid chromatography analysis. The extraction parameters, such as the volume of extraction solvent and disperser solvent, salt effect, sample volume, centrifuge rate, centrifuge time, extraction time, and temperature in the dispersive liquid-liquid microextraction process, were studied and optimized with the experimental design methods. Firstly, for the preliminary screening of the parameters the taguchi design was used and then, the fractional factorial design was used for significant factors optimization. At the optimum conditions, the calibration curves for ceftazidime indicated good linearity over the range of 0.001-10 μg/mL with correlation coefficients higher than the 0.98, and the limits of detection were 0.13 and 0.17 ng/mL, for water and urine samples, respectively. The proposed method successfully employed to determine ceftazidime in water and urine samples and good agreement between the experimental data and predictive values has been achieved. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Ultra-high performance liquid chromatography tandem mass spectrometry for the determination of five glycopeptide antibiotics in food and biological samples using solid-phase extraction.

    Science.gov (United States)

    Deng, Fenfang; Yu, Hong; Pan, Xinhong; Hu, Guoyuan; Wang, Qiqin; Peng, Rongfei; Tan, Lei; Yang, Zhicong

    2018-02-23

    This paper demonstrated the development and validation of an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of five glycopeptide antibiotics in food and biological samples. The target glycopeptide antibiotics were isolated from the samples by solvent extraction, and the extracts were cleaned with a tandem solid-phase extraction step using mixed strong cation exchange and hydrophilic/lipophilic balance cartridges. Subsequently, the analytes were eluted with different solvents, and then quantified by UHPLC-MS/MS in the positive ionization mode with multiple reaction monitoring. Under optimal conditions, good linear correlations were obtained for the five glycopeptide antibiotics in the concentration range of 1.0 μg/L to 20.0 μg/L, and with linear correlation coefficients >0.998. Employing this method, the target glycopeptide antibiotics in food and biological samples were identified with a recovery of 83.0-102%, and a low quantitation limit of 1.0 μg/kg in food and 2.0 μg/L in biological samples with low matrix effects. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Development of salt-tolerance interface for an high performance liquid chromatography/inductively coupled plasma mass spectrometry system and its application to accurate quantification of DNA samples.

    Science.gov (United States)

    Takasaki, Yuka; Sakagawa, Shinnosuke; Inagaki, Kazumi; Fujii, Shin-Ichiro; Sabarudin, Akhmad; Umemura, Tomonari; Haraguchi, Hiroki

    2012-02-03

    Accurate quantification of DNA is highly important in various fields. Determination of phosphorus by ICP-MS is one of the most effective methods for accurate quantification of DNA due to the fixed stoichiometry of phosphate to this molecule. In this paper, a smart and reliable method for accurate quantification of DNA fragments and oligodeoxythymidilic acids by hyphenated HPLC/ICP-MS equipped with a highly efficient interface device is presented. The interface was constructed of a home-made capillary-attached micronebulizer and temperature-controllable cyclonic spray chamber (IsoMist). As a separation column for DNA samples, home-made methacrylate-based weak anion-exchange monolith was employed. Some parameters, which include composition of mobile phase, gradient program, inner and outer diameters of capillary, temperature of spray chamber etc., were optimized to find the best performance for separation and accurate quantification of DNA samples. The proposed system could achieve many advantages, such as total consumption for small amount sample analysis, salt-tolerance for hyphenated analysis, high accuracy and precision for quantitative analysis. Using this proposed system, the samples of 20 bp DNA ladder (20, 40, 60, 80, 100, 120, 140, 160, 180, 200, 300, 400, 500 base pairs) and oligodeoxythymidilic acids (dT(12-18)) were rapidly separated and accurately quantified. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Electromembrane extraction of biogenic amines in food samples by a microfluidic-chip system followed by dabsyl derivatization prior to high performance liquid chromatography analysis.

    Science.gov (United States)

    Zarghampour, Fereshteh; Yamini, Yadollah; Baharfar, Mahroo; Faraji, Mohammad

    2018-06-29

    In the present research, an on-chip electromembrane extraction coupled with high performance liquid chromatography was developed for monitoring the trace levels of biogenic amines (BAs), including histamine, tryptamine, putrescine, cadaverine and spermidine in food samples. A porous polypropylene sheet membrane impregnated with an organic solvent was placed between the two parts of the chip device to separate the channels. Two platinum electrodes were mounted at the bottom of these channels, which were connected to a power supply, providing the electrical driving force for migration of ionized analytes from the sample solution through the porous sheet membrane into the acceptor phase. BAs were extracted from 2 mL aqueous sample solutions at neutral pH into 50 μL of acidified (HCl 90 mM) acceptor solution. Supported liquid membrane including NPOE containing 10% DEHP was used to ensure efficient extraction. Low voltage of 40 V was applied over the SLMs during extraction time. The influences of fundamental parameters affecting the transport of BAs were optimized. Under the optimized conditions, the relative standard deviations based on four replicate measurements were less than 8.0% and limit of detections were in range of 3.0-8.0 μg L -1 . Finally, the method was successfully applied to determinate BAs in the food samples and satisfactory results (recovery > 95.6) were obtained. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. The analysis of track chamber photographs using flying spot digitizers

    CERN Multimedia

    Powell, Brian W

    1966-01-01

    A vast quantity of data pours from the experiments on particle accelerators throughout the world. For example, over 300 000 photographs per week came from the three bubble chambers operating on the CERN PS at the end of 1965. The conventional method of processing these bubble chamber photographs is for each one of them to be examined ('scanned') to see whether it records an interesting particle interaction. The interesting photographs are then passed to hand operated measuring machines to obtain precise measurements of the particle trajectories recorded on the film. Similar measurements are carried out on photographs taken in film spark chamber experiments. This article on the Flying Spot Digitizers at CERN describes one of the most fruitful attempts to speed and make more accurate the process of analysis of bubble and spark chamber photographs. There are two types of Flying Spot Digitizer at CERN — the HPD or Hough Powell Device (named after Professor Hough and the author who, together, initiated the devel...

  15. Digitization of natural objects with micro CT and photographs.

    Science.gov (United States)

    Ijiri, Takashi; Todo, Hideki; Hirabayashi, Akira; Kohiyama, Kenji; Dobashi, Yoshinori

    2018-01-01

    In this paper, we present a three-dimensional (3D) digitization technique for natural objects, such as insects and plants. The key idea is to combine X-ray computed tomography (CT) and photographs to obtain both complicated 3D shapes and surface textures of target specimens. We measure a specimen by using an X-ray CT device and a digital camera to obtain a CT volumetric image (volume) and multiple photographs. We then reconstruct a 3D model by segmenting the CT volume and generate a texture by projecting the photographs onto the model. To achieve this reconstruction, we introduce a technique for estimating a camera position for each photograph. We also present techniques for merging multiple textures generated from multiple photographs and recovering missing texture areas caused by occlusion. We illustrate the feasibility of our 3D digitization technique by digitizing 3D textured models of insects and flowers. The combination of X-ray CT and a digital camera makes it possible to successfully digitize specimens with complicated 3D structures accurately and allows us to browse both surface colors and internal structures.

  16. Automated calculation of ptosis on lateral clinical photographs.

    Science.gov (United States)

    Lee, Juhun; Kim, Edward; Reece, Gregory P; Crosby, Melissa A; Beahm, Elisabeth K; Markey, Mia K

    2015-10-01

    The goal is to fully automate the calculation of a breast ptosis measure from clinical photographs through automatic localization of fiducial points relevant to the measure. Sixty-eight women (97 clinical photographs) who underwent or were scheduled for breast reconstruction were included. The photographs were divided into a development set (N = 49) and an evaluation set (N = 48). The breast ptosis measure is obtained automatically from distances between three fiducial points: the nipple, the lowest visible point of breast (LVP), and the lateral terminus of the inframammary fold (LT). The nipple is localized using the YIQ colour space to highlight the contrast between the areola and the surrounding breast skin. The areola is localized using its shape, location and high Q component intensity. The breast contour is estimated using Dijkstra's shortest path algorithm on the gradient of the photograph in greyscale. The lowest point of the estimated contour is set as the LVP. To locate the anatomically subtle LT, the location of patient's axilla is used as a reference. The algorithm's efficacy was evaluated by comparing manual and automated localizations of the fiducial points. The average nipple diameter was used as a cut-off to define success. The algorithm showed 90, 91 and 83% accuracy for locating the nipple, LVP and LT in the evaluation set, respectively. This study presents a new automated algorithm that may facilitate the quantification of breast ptosis from lateral views of patients' photographs. © 2015 John Wiley & Sons, Ltd.

  17. Food photographs in portion size estimation among adolescent Mozambican girls.

    Science.gov (United States)

    Korkalo, Liisa; Erkkola, Maijaliisa; Fidalgo, Lourdes; Nevalainen, Jaakko; Mutanen, Marja

    2013-09-01

    To assess the validity of food photographs in portion size estimation among adolescent girls in Mozambique. The study was carried out in preparation for the larger ZANE study, which used the 24 h dietary recall method. Life-sized photographs of three portion sizes of two staple foods and three sauces were produced. Participants ate weighed portions of one staple food and one sauce. After the meal, they were asked to estimate the amount of food with the aid of the food photographs. Zambezia Province, Mozambique. Ninety-nine girls aged 13–18 years. The mean differences between estimated and actual portion sizes relative to the actual portion size ranged from 219% to 8% for different foods. The respective mean difference for all foods combined was 25% (95% CI 212, 2 %). Especially larger portions of the staple foods were often underestimated. For the staple foods, between 62% and 64% of the participants were classified into the same thirds of the distribution of estimated and actual food consumption and for sauces, the percentages ranged from 38% to 63%. Bland–Altman plots showed wide limits of agreement. Using life-sized food photographs among adolescent Mozambican girls resulted in a rather large variation in the accuracy of individuals’ estimates. The ability to rank individuals according to their consumption was, however, satisfactory for most foods. There seems to be a need to further develop and test food photographs used in different populations in Sub-Saharan Africa to improve the accuracy of portion size estimates.

  18. Beauty is in the eye of the photographer

    CERN Multimedia

    Roberto Cantoni

    2010-01-01

    On Saturday 7 August, over 200 amateur photographers took part in the first “Particle Physics Photowalk”, a photo contest organized by CERN in collaboration with DESY in Germany, Fermilab in the USA, KEK in Japan and TRIUMF in Canada. As of mid-September you will be able to discover on a dedicated website the five particle physics laboratories as seen through the lenses of the participants.   Photographers at the photowalk. The Photowalk was a unique opportunity for the participants to photograph state-of-the-art accelerators and detectors in all their beauty and complexity. At CERN, the photographers were able to visit and take pictures of Linac4, the Computing Centre, SM18 and CLIC. Photographers came to CERN from Switzerland, France, the UK and Germany (one even came from the USA just for the event). “The 48 places available for the Photowalk at CERN were snatched up within days through the dedicated website”, says Sophie Tesauri from the Communication G...

  19. Using Network Oriented Research Assistant (NORA) Technology to Compare Digital Photographic With In-Person Assessment of Acne Vulgaris.

    Science.gov (United States)

    Singer, Hannah M; Almazan, Timothy; Craft, Noah; David, Consuelo V; Eells, Samantha; Erfe, Crisel; Lazzaro, Cynthia; Nguyen, Kathy; Preciado, Katy; Tan, Belinda; Patel, Vishal A

    2018-02-01

    Teledermatology has undergone exponential growth in the past 2 decades. Many technological innovations are becoming available without necessarily undergoing validation studies for specific dermatologic applications. To determine whether patient-taken photographs of acne using Network Oriented Research Assistant (NORA) result in similar lesion counts and Investigator's Global Assessment (IGA) findings compared with in-person examination findings. This pilot reliability study enrolled consecutive patients with acne vulgaris from a single general dermatology practice in Los Angeles, California, who were able to use NORA on an iPhone 6 to take self-photographs. Patients were enrolled from January 1 through March 31, 2016. Each individual underwent in-person and digital evaluation of his or her acne by the same dermatologist. A period of at least 1 week separated the in-person and digital assessments of acne. All participants were trained on how to use NORA on the iPhone 6 and take photographs of their face with the rear-facing camera. Reliability of patient-taken photographs with NORA for acne evaluation compared with in-person examination findings. Acne assessment measures included lesion count (total, inflammatory, noninflammatory, and cystic) and IGA for acne severity. A total of 69 patients (37 male [54%] and 32 female [46%]; mean [SD] age, 22.7 [7.7] years) enrolled in the study. The intraclass correlation coefficients of in-person and photograph-based acne evaluations indicated strong agreement. The intraclass correlation coefficient for total lesion count was 0.81; for the IGA, 0.75. Inflammatory lesion count, noninflammatory lesion count, and cyst count had intraclass correlation coefficients of 0.72, 0.72, and 0.82, respectively. This study found agreement between acne evaluations performed in person and from self-photographs with NORA. As a reliable telehealth technology for acne, NORA can be used as a teledermatology platform for dermatology research and can

  20. Novel magnetic hollow zein nanoparticles for preconcentration of chlorpyrifos from water and soil samples prior to analysis via high-performance liquid chromatography (HPLC).

    Science.gov (United States)

    Rahimi Moghadam, Mojtaba; Zargar, Behrooz; Rastegarzadeh, Saadat

    2018-04-30

    Herein, magnetically hollow zein nanoparticles were synthesized and used as a magnetic sorbent for the preconcentration of chlorpyrifos and its analysis by high-performance liquid chromatography (HPLC). Morphology of the sorbent was characterized by transmission electron microscopy (TEM). In this study, the effects of important parameters such as pH of the solution, adsorption and desorption time, type and volume of desorption solvent, and salt addition were investigated. Under optimized experimental conditions, the linear range was from 50 to 2000 μg mL-1, and an LOD of 25 μg L-1 was calculated. The relative standard deviations (RSD) varied from 3.8 to 5.1% (n = 5). The enrichment factors for 50 and 100 μg L-1 samples were calculated as 187 and 210, respectively. The developed method was successfully applied in soil and water samples and showed good extraction recoveries.

  1. Mature women’s attitude toward fashion photographs

    Directory of Open Access Journals (Sweden)

    Luis Fernando Hor-Meyll

    2015-12-01

    Full Text Available Objective –To investigate the influence of the cognitive age of upper-middle class mature women regarding their attitude towards photographs of articles of clothing, as a result of their identification with the model wearing them. Design/methodology/approach – Experiment with a sample of 164 women, aged 55- 70 years old, living in Rio de Janeiro. The questionnaire was were based on scales found in the literature. Theoretical foundation Cognitive age (Barak; Schiffman, 1981; Leventhal, 1997; Szmigin; Carrigan, 2000; Wray; Hodges, 2008; Amaro; Johann; Meira, 2007; Birtwistle; Tsim, 2005; Moschis, 2003; Moschis; Mathur, 2006 Mature woman and fashion (Schewe, 1988; Slongo et al., 2009; Thomas; Peters, 2009; Moschis, Lee, & Mathur, 1997; Young; Miller, 2006; Wilkes, 1992; Facenda, 2000; Holmlund; Hagman; Polsa, 2010; Szmigin; Carrigan, 2000. Mature woman and advertising (Moschis, 2003; Venkatesh et al., 2010; Nam et al., 2007; Kozar; Damhorst, 2008; Araujo, Casotti, Da Silva, & Pessôa, 2015 Findings – The identification with the model was greater when the respondent perceived her as being close to her own cognitive age (F(1, 162 =615.87, p=0.000. The attitude toward the collection was more positive when the respondent perceived the model as being closer to her own cognitive age (F (2, 162 =1074.55, p=0.000. Practical implications –The degree of the consumer’s identification is greater when the model appears to be the same cognitive age as the consumer. When the consumer believes that the model is close to her own cognitive age, her attitude toward the displayed item is more positive.

  2. Ultra-high performance liquid chromatography with fluorescence detection following salting-out assisted liquid-liquid extraction for the analysis of benzimidazole residues in farm fish samples.

    Science.gov (United States)

    Tejada-Casado, Carmen; Lara, Francisco J; García-Campaña, Ana M; Del Olmo-Iruela, Monsalud

    2018-03-30

    Ultra-high performance liquid chromatography (UHPLC) coupled with fluorescence detection (FL) has been proposed for the first time to determine thirteen benzimidazoles (BZs) in farmed fish samples. In order to optimize the chromatographic separation, parameters such as mobile phase composition and flow rate were carefully studied, establishing a gradient mode with a mobile phase consisted of water (solvent A) and acetonitrile (solvent B) at a flow rate of 0.4 mL/min. The separation was performed on a Zorbax Eclipse Plus RRHD C 18 column (50 × 2.1 mm, 1.8 μm), involving a total analysis time lower than 12 min. Salting-out assisted liquid-liquid extraction (SALLE) was applied as sample treatment to different types of farmed fish (trout, sea bream and sea bass). To obtain satisfactory extraction efficiencies for the studied analytes, several parameters affecting the SALLE procedure were optimized including the amount of sample, type and volume of the extraction solvent, and the nature and amount of the salt used. Characterization of the method in terms of performance characteristics was carried out, obtaining satisfactory results for the linearity (R 2  ≥ 0.997), repeatability (RSD ≤ 6.1%), reproducibility (RSD ≤ 10.8%) and recoveries (R ≥ 79%; RSD ≤ 7.8%). Detection limits between 0.04-29.9 μg kg -1 were obtained, demonstrating the applicability of this fast, simple and environmentally friendly method. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Estimation of the sugar cane cultivated area from LANDSAT images using the two phase sampling method

    Science.gov (United States)

    Parada, N. D. J. (Principal Investigator); Cappelletti, C. A.; Mendonca, F. J.; Lee, D. C. L.; Shimabukuro, Y. E.

    1982-01-01

    A two phase sampling method and the optimal sampling segment dimensions for the estimation of sugar cane cultivated area were developed. This technique employs visual interpretations of LANDSAT images and panchromatic aerial photographs considered as the ground truth. The estimates, as a mean value of 100 simulated samples, represent 99.3% of the true value with a CV of approximately 1%; the relative efficiency of the two phase design was 157% when compared with a one phase aerial photographs sample.

  4. Image processing and data reduction of Apollo low light level photographs

    Science.gov (United States)

    Alvord, G. C.

    1975-01-01

    The removal of the lens induced vignetting from a selected sample of the Apollo low light level photographs is discussed. The methods used were developed earlier. A study of the effect of noise on vignetting removal and the comparability of the Apollo 35mm Nikon lens vignetting was also undertaken. The vignetting removal was successful to about 10% photometry, and noise has a severe effect on the useful photometric output data. Separate vignetting functions must be used for different flights since the vignetting function varies from camera to camera in size and shape.

  5. Environmental waste site characterization utilizing aerial photographs and satellite imagery: Three sites in New Mexico, USA

    International Nuclear Information System (INIS)

    Van Eeckhout, E.; Pope, P.; Becker, N.; Wells, B.; Lewis, A.; David, N.

    1996-01-01

    The proper handling and characterization of past hazardous waste sites is becoming more and more important as world population extends into areas previously deemed undesirable. Historical photographs, past records, current aerial satellite imagery can play an important role in characterizing these sites. These data provide clear insight into defining problem areas which can be surface samples for further detail. Three such areas are discussed in this paper: (1) nuclear wastes buried in trenches at Los Alamos National Laboratory, (2) surface dumping at one site at Los Alamos National Laboratory, and (3) the historical development of a municipal landfill near Las Cruces, New Mexico

  6. Performance enhancement of the single-phase series active filter by employing the load voltage waveform reconstruction and line current sampling delay reduction methods

    DEFF Research Database (Denmark)

    Senturk, O.S.; Hava, A.M.

    2011-01-01

    This paper proposes the waveform reconstruction method (WRM), which is utilized in the single-phase series active filter's (SAF's) control algorithm, in order to extract the load harmonic voltage component of voltage harmonic type single-phase diode rectifier loads. Employing WRM and the line...... current sampling delay reduction method, a single-phase SAF compensated system provides higher harmonic isolation performance and higher stability margins compared to the system using conventional synchronous-reference-frame-based methods. The analytical, simulation, and experimental studies of a 2.5 k...

  7. Unfamiliar face matching with photographs of infants and children

    Directory of Open Access Journals (Sweden)

    Robin S.S. Kramer

    2018-06-01

    chance levels for one image set and above chance (although still low for the other set. As expected, participants were able to judge the sex of children (aged 4–5 from their faces. Discussion Identity matching with infant and child images resulted in low levels of performance, which were significantly worse than for an adult face matching task. Taken together, the results of the experiments presented here provide evidence that child facial photographs are ineffective for use in real-world identification.

  8. Sensitive determination of iodine species, including organo-iodine, for freshwater and seawater samples using high performance liquid chromatography and spectrophotometric detection

    International Nuclear Information System (INIS)

    Schwehr, Kathleen A.; Santschi, Peter H.

    2003-01-01

    In order to more effectively use iodine isotope ratios, 129 I/ 127 I, as hydrological and geochemical tracers in aquatic systems, a new high performance liquid chromatography (HPLC) method was developed for the determination of iodine speciation. The dissolved iodine species that dominate natural water systems are iodide, iodate, and organic iodine. Using this new method, iodide was determined directly by combining anion exchange chromatography and spectrophotometry. Iodate and the total of organic iodine species are determined as iodide, with minimal sample preparation, compared to existing methods. The method has been applied to quantitatively determine iodide, iodate as the difference of total inorganic iodide and iodide after reduction of the sample by NaHSO 3 , and organic iodine as the difference of total iodide (after organic decomposition by dehydrohalogenation and reduction by NaHSO 3 ) and total inorganic iodide. Analytical accuracy was tested: (1) against certified reference material, SRM 1549, powdered milk (NIST); (2) through the method of standard additions; and (3) by comparison to values of environmental waters measured independently by inductively coupled plasma mass spectrometry (ICP-MS). The method has been successfully applied to measure the concentrations of iodide species in rain, surface and ground water, estuarine and seawater samples. The detection limit was ∼1 nM (0.2 ppb), with less than 3% relative standard deviation (R.S.D.) for samples determined by standard additions to an iodide solution of 20 nM in 0.1 M NaCl. This technique is one of the few methods sensitive enough to accurately quantify stable iodine species at nanomolar concentrations in aquatic systems across a range of matrices, and to quantitatively measure organic iodine. Additionally, this method makes use of a very dilute mobile phase, and may be applied to small sample volumes without pre-column concentration or post-column reactions

  9. Utility of a Systematic Approach to Teaching Photographic Nasal Analysis to Otolaryngology Residents.

    Science.gov (United States)

    Robitschek, Jon; Dresner, Harley; Hilger, Peter

    2017-12-01

    Photographic nasal analysis constitutes a critical step along the path toward accurate diagnosis and precise surgical planning in rhinoplasty. The learned process by which one assesses photographs, analyzes relevant anatomical landmarks, and generates a global view of the nasal aesthetic is less widely described. To discern the common pitfalls in performing photographic nasal analysis and to quantify the utility of a systematic approach model in teaching photographic nasal analysis to otolaryngology residents. This prospective observational study included 20 participants from a university-based otolaryngology residency program. The control and intervention groups underwent baseline graded assessment of 3 patients. The intervention group received instruction on a systematic approach model for nasal analysis, and both groups underwent postintervention testing at 10 weeks. Data were collected from October 1, 2015, through June 1, 2016. A 10-minute, 11-slide presentation provided instruction on a systematic approach to nasal analysis to the intervention group. Graded photographic nasal analysis using a binary 18-point system. The 20 otolaryngology residents (15 men and 5 women; age range, 24-34 years) were adept at mentioning dorsal deviation and dorsal profile with focused descriptions of tip angle and contour. Areas commonly omitted by residents included verification of the Frankfort plane, position of the lower lateral crura, radix position, and ratio of the ala to tip lobule. The intervention group demonstrated immediate improvement after instruction on the teaching model, with the mean (SD) postintervention test score doubling compared with their baseline performance (7.5 [2.7] vs 10.3 [2.5]; P Otolaryngology residents demonstrated proficiency at incorporating nasal deviation, tip angle, and dorsal profile contour into their nasal analysis. They often omitted verification of the Frankfort plane, position of lower lateral crura, radix depth, and ala-to-tip lobule

  10. Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.

    Science.gov (United States)

    Li, Zhixi; He, Yifan; Keel, Stuart; Meng, Wei; Chang, Robert T; He, Mingguang

    2018-03-02

    To assess the performance of a deep learning algorithm for detecting referable glaucomatous optic neuropathy (GON) based on color fundus photographs. A deep learning system for the classification of GON was developed for automated classification of GON on color fundus photographs. We retrospectively included 48 116 fundus photographs for the development and validation of a deep learning algorithm. This study recruited 21 trained ophthalmologists to classify the photographs. Referable GON was defined as vertical cup-to-disc ratio of 0.7 or more and other typical changes of GON. The reference standard was made until 3 graders achieved agreement. A separate validation dataset of 8000 fully gradable fundus photographs was used to assess the performance of this algorithm. The area under receiver operator characteristic curve (AUC) with sensitivity and specificity was applied to evaluate the efficacy of the deep learning algorithm detecting referable GON. In the validation dataset, this deep learning system achieved an AUC of 0.986 with sensitivity of 95.6% and specificity of 92.0%. The most common reasons for false-negative grading (n = 87) were GON with coexisting eye conditions (n = 44 [50.6%]), including pathologic or high myopia (n = 37 [42.6%]), diabetic retinopathy (n = 4 [4.6%]), and age-related macular degeneration (n = 3 [3.4%]). The leading reason for false-positive results (n = 480) was having other eye conditions (n = 458 [95.4%]), mainly including physiologic cupping (n = 267 [55.6%]). Misclassification as false-positive results amidst a normal-appearing fundus occurred in only 22 eyes (4.6%). A deep learning system can detect referable GON with high sensitivity and specificity. Coexistence of high or pathologic myopia is the most common cause resulting in false-negative results. Physiologic cupping and pathologic myopia were the most common reasons for false-positive results. Copyright © 2018 American Academy of Ophthalmology. Published by

  11. Stock Photographs Do Not Comply With Infant Safe Sleep Guidelines.

    Science.gov (United States)

    Goodstein, Michael H; Lagon, Elena; Bell, Theodore; Joyner, Brandi L; Moon, Rachel Y

    2018-04-01

    We evaluated images in popular stock photography websites for adherence with American Academy of Pediatrics (AAP) guidelines for safe infant sleep practices. Three top stock photo websites were used to collect photographs generated from key phrases. All images depicting an infant sleep environment were analyzed for consistency with AAP guidelines. Descriptive statistics, chi-square and z test of proportions, were conducted. A total of 1233 of 1947 stock photographs showed sleeping infants on a flat surface. In all, 627 (50.8%) photographs showed the infant in the supine position and 79 (5%) of all infant sleep environments were adherent with AAP recommendations. Bedding inconsistent with safe sleep recommendations was identified in 1133 images (71.3%), with blankets noted in 49.5%. Images depicting sleeping infants on stock photography sites do not routinely adhere to AAP recommendations. Media messages inconsistent with health care messages create confusion and misinformation about infant sleep safety and may lead inadvertently to unsafe practices.

  12. Photographs from where the world is called Galicia

    Directory of Open Access Journals (Sweden)

    Margarita Ledo Andión, Ph. D.

    2010-01-01

    Full Text Available If our main goal is to reconstruct the history of photojournalism in Galicia from the photograph as part of the journalistic discourse, it leads us to confirm some uncertainties that disable a linear story by being unable to construct, much less in the case of a social institution as the press, the period leading to the Second Republic with the long years of dictatorship, nor able to extract a major influence by the photographic practices of the early years of political transition in the subsequent configuration of the role of photojournalism in the media enterprises. This study tries to establish an anthropological link between certain images, to punctuate the signification of the photographic act and, finally, to highlight the value of the act of viewing, and the photos remembered, those images that among all the other images are ours, and we recover them so that other people love them too.

  13. Effects of radiation on photographic film. A study

    International Nuclear Information System (INIS)

    Dutton, D.M.

    1971-01-01

    This study of the effects of radiation on photographic film is related to the Nevada Test Site's underground nuclear testing program, which has been active since implementation of the Limited Test Ban Treaty of 1963. Residual radioactivity, which has accidentally been released on several tests, adversely affects the photographic film used in test data acquisition. The report defines this problem in terms of radiation-caused image degradation, radiation/matter interactions, types of radiation released by accidental venting, and the photographic effects of gamma and x radiation. Techniques and experimental findings are documented that may be useful in recovering information from radiation-fogged film. Techniques discussed include processing methods, shielding, image enhancement techniques, and operational handling of potentially irradiated film. (U.S.)

  14. ARIADNE, a Photographic LAr TPC at the CERN Neutrino Platform

    CERN Document Server

    Mavrokoridis, K; Nessi, M; Roberts, A; Smith, N A; Touramanis, C; CERN. Geneva. SPS and PS Experiments Committee; SPSC

    2016-01-01

    This letter of intent describes a novel and innovative two-phase LAr TPC with photographic capabilities as an attractive alternative readout method to the currently accepted segmented THGEMs which will require many thousands of charge readout channels for kton-scale two-phase TPCs. These colossal LAr TPCs will be used for the future long-baseline-neutrino-oscillation experiments. Optical readout also presents many other clear advantages over current readout techniques such as ease of scalability, upgrade, installation and maintenance, and cost effectiveness. This technology has already been demonstrated at the Liverpool LAr facility with the photographic capturing of cosmic muon tracks and single gammas using a 40-litre prototype. We have now secured ERC funding to develop this further with the ARIADNE programme. ARIADNE will be a 1-ton two-phase LAr TPC utilizing THGEM and EMCCD camera readouts in order to photograph interactions, allowing for track reconstruction and particle identification. We are request...

  15. Determination of pharmaceutical compounds in surface- and ground-water samples by solid-phase extraction and high-performance liquid chromatography-electrospray ionization mass spectrometry

    Science.gov (United States)

    Cahill, J.D.; Furlong, E.T.; Burkhardt, M.R.; Kolpin, D.; Anderson, L.G.

    2004-01-01

    Commonly used prescription and over-the-counter pharmaceuticals are possibly present in surface- and ground-water samples at ambient concentrations less than 1 μg/L. In this report, the performance characteristics of a combined solid-phase extraction isolation and high-performance liquid chromatography–electrospray ionization mass spectrometry (HPLC–ESI-MS) analytical procedure for routine determination of the presence and concentration of human-health pharmaceuticals are described. This method was developed and used in a recent national reconnaissance of pharmaceuticals in USA surface waters. The selection of pharmaceuticals evaluated for this method was based on usage estimates, resulting in a method that contains compounds from diverse chemical classes, which presents challenges and compromises when applied as a single routine analysis. The method performed well for the majority of the 22 pharmaceuticals evaluated, with recoveries greater than 60% for 12 pharmaceuticals. The recoveries of angiotensin-converting enzyme inhibitors, a histamine (H2) receptor antagonist, and antihypoglycemic compound classes were less than 50%, but were retained in the method to provide information describing the potential presence of these compounds in environmental samples and to indicate evidence of possible matrix enhancing effects. Long-term recoveries, evaluated from reagent-water fortifications processed over 2 years, were similar to initial method performance. Method detection limits averaged 0.022 μg/L, sufficient for expected ambient concentrations. Compound-dependent matrix effects on HPLC/ESI-MS analysis, including enhancement and suppression of ionization, were observed as a 20–30% increase in measured concentrations for three compounds and greater than 50% increase for two compounds. Changing internal standard and more frequent ESI source maintenance minimized matrix effects. Application of the method in the national survey demonstrates that several

  16. Dispersion assessment in the location of facial landmarks on photographs.

    Science.gov (United States)

    Campomanes-Álvarez, B R; Ibáñez, O; Navarro, F; Alemán, I; Cordón, O; Damas, S

    2015-01-01

    The morphological assessment of facial features using photographs has played an important role in forensic anthropology. The analysis of anthropometric landmarks for determining facial dimensions and angles has been considered in diverse forensic areas. Hence, the quantification of the error associated to the location of facial landmarks seems to be necessary when photographs become a key element of the forensic procedure. In this work, we statistically evaluate the inter- and intra-observer dispersions related to the facial landmark identification on photographs. In the inter-observer experiment, a set of 18 facial landmarks was provided to 39 operators. They were requested to mark only those that they could precisely place on 10 photographs with different poses (frontal, oblique, and lateral views). The frequency of landmark location was studied together with their dispersion. Regarding the intra-observer evaluation, three participants identified 13 facial points on five photographs classified in the frontal and oblique views. Each landmark location was repeated five times at intervals of at least 24 h. The frequency results reveal that glabella, nasion, subnasale, labiale superius, and pogonion obtained the highest location frequency in the three image categories. On the contrary, the lowest rate corresponds to labiale inferius and menton. Meanwhile, zygia, gonia, and gnathion were significantly more difficult to locate than other facial landmarks. They produced a significant effect on the dispersion depending on the pose of the image where they were placed, regardless of the type of observer that positioned them. In particular, zygia and gonia presented a statistically greater variation in the three image poses, while the location of gnathion is less precise in oblique view photographs. Hence, our findings suggest that the latter landmarks tend to be highly variable when determining their exact position.

  17. Determination of the analytical performance of a headspace capillary gas chromatographic technique and karl Fischer coulometric titration by system calibration using oil samples containing known amounts of moisture.

    Science.gov (United States)

    Jalbert, J; Gilbert, R; Tétreault, P

    1999-08-01

    Over the past few years, concerns have been raised in the literature about the accuracy of the Karl Fischer (KF) method for assessing moisture in transformer mineral oils. To better understand this issue, the performance of a static headspace capillary gas chromatographic (HS-CGC) technique was compared to that of KF coulometric titration by analyzing moisture in samples containing known amounts of water and various samples obtained from the National Institute of Standards and Technology (NIST). Two modes of adding samples into the KF vessel were used:  direct injection and indirect injection via an azeotropic distillation of the moisture with toluene. Under the conditions used for direct injection, the oil matrix was totally dissolved in the anolyte, which allowed the moisture to be titrated in a single-phase solution rather than in a suspension. The results have shown that when HS-CGC and combined azeotropic distillation/KF titration are calibrated with moisture-in-oil standards, a linear relation is observed over 0-60 ppm H(2)O with a correlation coefficient better than 0.9994 (95% confidence), with the regression line crossing through zero. A similar relation can also be observed when calibration is achieved by direct KF addition of standards prepared with octanol-1, but in this case an intercept of 4-5 ppm is noted. The amount of moisture determined by curve interpolation in NIST reference materials by the three calibrated systems ranges from 13.0 to 14.8 ppm for RM 8506 and 42.5 to 46.4 ppm for RM 8507, and in any case, the results were as high as those reported in the literature with volumetric KF titration. However, titration of various dehydrated oil and solvent samples showed that direct KF titration is affected by a small bias when samples contain very little moisture. The source of error after correction for the large sample volume used for the determination (8 mL) is about 6 ppm for Voltesso naphthenic oil and 4 ppm for toluene, revealing a matrix

  18. Adobe Photoshop CS5 for Photographers The Ultimate Workshop

    CERN Document Server

    Evening, Martin

    2010-01-01

    If you already have a good knowledge of Adobe Photoshop and are looking to advance your skills, Adobe Photoshop CS5 for Photographers: The Ultimate Workshop is the book you've been waiting for.  Renowned photographers Martin Evening and Jeff Schewe impart their Photoshop tips and workflow, showing you how to use a vast array of rarely seen advanced Photoshop techniques.  Whether the subject is serious retouching work, weird and wonderful compositions, or planning a shoot before you've even picked up a camera, you can be sure that the advice is based on years of practical experience.

  19. "Objects and Places” – Photographs by Alan Trachtenberg


    Directory of Open Access Journals (Sweden)

    Géraldine Chouard

    2011-04-01

    Full Text Available  “Black-and-white images of diverse scenes in America—ranging from a Mississippi ���ghost” town to rooftops in Pennsylvania to an upper New York state racetrack—are featured in a new exhibition of photographs by Yale professor Alan Trachtenberg at the Henry Koerner Center for Emeritus Faculty. The exhibit, titled “Objects and Places,” is a selection of 22 photographs that Trachtenberg made over the past 30 years using a large-format (8×10 camera.” [Excerpt from the Yale Daily Bulletin]The foll...

  20. Adobe Photoshop CS4 for Photographers The Ultimate Workshop

    CERN Document Server

    Evening, Martin

    2009-01-01

    Professional commercial photographer and digital imager Jeff Schewe (based in Chicago, USA) has teamed up with best-selling Photoshop author Martin Evening to create this goldmine of information for advanced Photoshop users. Building on Martin Evening's successful Adobe Photoshop for Photographers series of titles, this new guide takes the same winning approach and applies it to a professional Photoshop workflow. Highly visual, with clear, step-by-step tutorials, this advanced guide will really appeal to those who want to see how the experts approach Photoshop, produci

  1. PaintShop Pro x6 for photographers

    CERN Document Server

    McMahon, Ken

    2014-01-01

    Written for photographers of all levels, PaintShop Pro X6 for Photographers is packed with inspirational, full-color images and easy-to-follow step-by-step projects that will have you producing great images in PaintShop Pro in no time! Everything you need to enhance and improve your digital photography is right here in this Corel® endorsed guide.In this new edition, Ken McMahon looks at the pros and cons of the new, faster 64-bit version of the software and covers new features, including working with the Instant Effects palette, using the Smart selection brush, mapping photos, automatically ta

  2. Conversation between photographer Brian Duffy and Grant Scott

    OpenAIRE

    Scott, Grant

    2010-01-01

    Brian Duffy (15 June 1933 – 31 May 2010) was an English photographer and film producer, best remembered for his fashion and portrait photography of the 1960s and 1970s.\\ud \\ud In 1957 Duffy was hired by British Vogue working under art director John Parsons where he remained working until 1963. During this time he worked closely with top models Jean Shrimpton (who he introduced to David Bailey), Paulene Stone, Joy Weston, Jennifer Hocking and Judy Dent.\\ud \\ud With fellow photographers; David ...

  3. Study of the international epidemiology of androgenetic alopecia in young caucasian men using photographs from the internet

    Directory of Open Access Journals (Sweden)

    Yaniv Shalom Avital

    2015-01-01

    Full Text Available Background: The epidemiological evaluation of androgenetic alopecia (AGA is based mainly on direct observation and questionnaires. The international epidemiology and environmental risk factors of AGA in young Caucasian men remain unknown. Aim: To use photographs and data from the Internet to evaluate severe AGA and generate greater understanding of the international epidemiology of the disorder in young Caucasian men. Materials and Methods: A population-based cross-sectional study design was used. The sample included 26,340 Caucasian men aged 30 to 40 years who had uploaded profiles to two dating websites. Their photographs were evaluated for AGA and graded as follows: severe AGA (Norwood type VI-VII, non-severe AGA, and unknown. Epidemiological data were collected from the sites. Logistic regression was used to analyze the effect of risk factors on the prevalence of severe AGA. Results : The overall success rate for identifying severe AGA by indirect evaluation of Internet photographs was 94%. The prevalence of severe AGA was 15.33% overall and varied significantly by geographical region. The risk of having severe AGA was increased by 1.092 for every year of age between 30 and 40 years. Severe AGA was more prevalent in subjects with higher body mass index. Conclusions: Photographs from the Internet can be used to evaluate severe AGA in epidemiological studies. The prevalence of severe AGA in young Caucasian men increases with age and varies by geographical region. Body mass index is an environmental risk factor for severe AGA.

  4. Study of the International Epidemiology of Androgenetic Alopecia in Young Caucasian Men Using Photographs From the Internet.

    Science.gov (United States)

    Avital, Yaniv Shalom; Morvay, Marta; Gaaland, Magdolna; Kemény, Lajos

    2015-01-01

    The epidemiological evaluation of androgenetic alopecia (AGA) is based mainly on direct observation and questionnaires. The international epidemiology and environmental risk factors of AGA in young Caucasian men remain unknown. To use photographs and data from the Internet to evaluate severe AGA and generate greater understanding of the international epidemiology of the disorder in young Caucasian men. A population-based cross-sectional study design was used. The sample included 26,340 Caucasian men aged 30 to 40 years who had uploaded profiles to two dating websites. Their photographs were evaluated for AGA and graded as follows: severe AGA (Norwood type VI-VII), non-severe AGA, and unknown. Epidemiological data were collected from the sites. Logistic regression was used to analyze the effect of risk factors on the prevalence of severe AGA. The overall success rate for identifying severe AGA by indirect evaluation of Internet photographs was 94%. The prevalence of severe AGA was 15.33% overall and varied significantly by geographical region. The risk of having severe AGA was increased by 1.092 for every year of age between 30 and 40 years. Severe AGA was more prevalent in subjects with higher body mass index. Photographs from the Internet can be used to evaluate severe AGA in epidemiological studies. The prevalence of severe AGA in young Caucasian men increases with age and varies by geographical region. Body mass index is an environmental risk factor for severe AGA.

  5. Measurement of K-27, an oxime-type cholinesterase reactivator by high-performance liquid chromatography with electrochemical detection from different biological samples.

    Science.gov (United States)

    Gyenge, Melinda; Kalász, Huba; Petroianu, George A; Laufer, Rudolf; Kuca, Kamil; Tekes, Kornélia

    2007-08-17

    K-27 is a bisquaternary asymmetric pyridinium aldoxime-type cholinesterase reactivator of use in the treatment of poisoning with organophosphorous esterase inhibitors. A sensitive, simple and reliable reverse-phase high-performance liquid chromatographic method with electrochemical detection was developed for the measurement of K-27 concentrations in rat brain, cerebrospinal fluid, serum and urine samples. Male Wistar rats were treated intramuscularly with K-27 and the samples were collected 60 min later. Separation was carried out on an octadecyl silica stationary phase and a disodium phosphate solution (pH 3.7) containing citric acid, octane sulphonic acid and acetonitrile served as mobile phase. Measurements were carried out at 30 degrees C at E(ox) 0.65 V. The calibration curve was linear through the range of 10-250 ng/mL. Accuracy, precision and the limit of detection calculated were satisfactory according to internationally accepted criteria. Limit of quantitation was 10 ng/mL. The method developed is reliable and sensitive enough for monitoring K-27 levels from different biological samples including as little as 10 microL of cerebrospinal fluid. The method--with slight modification in the composition of the mobile phase--can be used to measure a wide range of other related pyridinium aldoxime-type cholinesterase reactivators.

  6. Simultaneous identification and quantification of bisphenol A and 12 bisphenol analogues in environmental samples using precolumn derivatization and ultra high performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Wang, Zhonghe; Yu, Jing; Yao, Jiaxi; Wu, Linlin; Xiao, Hang; Wang, Jun; Gao, Rong

    2018-02-10

    A method for the identification and quantification of bisphenol A and 12 bisphenol analogues in river water and sediment samples combining liquid-liquid extraction, precolumn derivatization, and ultra high-performance liquid chromatography coupled with tandem mass spectrometry was developed and validated. Analytes were extracted from the river water sample using a liquid-liquid extraction method. Dansyl chloride was selected as a derivatization reagent. Derivatization reaction conditions affecting production of the dansyl derivatives were tested and optimized. All the derivatized target compounds were well separated and eluted in 10 min. Dansyl chloride labeled compounds were analyzed using a high-resolution mass spectrometer with electrospray ionization in the positive mode, and the results were confirmed and quantified in the parallel reaction monitoring mode. The method validation results showed a satisfactory level of sensitivity. Linearity was assessed using matrix-matched standard calibration, and good correlation coefficients were obtained. The limits of quantification for the analytes ranged from 0.005 to 0.02 ng/mL in river water and from 0.15 to 0.80 ng/g in sediment. Good reproducibility of the method in terms of intra- and interday precision was achieved, yielding relative standard deviations of less than 10.1 and 11.6%, respectively. Finally, this method was successfully applied to the analysis of real samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Speciation of mercury in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Jia Xiaoyu; Han Yi; Liu Xinli [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Science, Changchun 130022 (China); Graduate School of Chinese Academy of Sciences, Beijing 100039 (China); Duan Taicheng, E-mail: tcduan@ciac.jl.cn [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Science, Changchun 130022 (China); Chen Hangting, E-mail: htchen@ciac.jl.cn [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Science, Changchun 130022 (China)

    2011-01-15

    The dispersive liquid-liquid microextraction (DLLME) combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry for the speciation of mercury in water samples was described. Firstly methylmercury (MeHg{sup +}) and mercury (Hg{sup 2+}) were complexed with sodium diethyldithiocarbamate, and then the complexes were extracted into carbon tetrachloride by using DLLME. Under the optimized conditions, the enrichment factors of 138 and 350 for MeHg{sup +} and Hg{sup 2+} were obtained from only 5.00 mL sample solution. The detection limits of the analytes (as Hg) were 0.0076 ng mL{sup -1} for MeHg{sup +} and 0.0014 ng mL{sup -1} for Hg{sup 2+}, respectively. The relative standard deviations for ten replicate measurements of 0.5 ng mL{sup -1} MeHg{sup +} and Hg{sup 2+} were 6.9% and 4.4%, respectively. Standard reference material of seawater (GBW(E)080042) was analyzed to verify the accuracy of the method and the results were in good agreement with the certified values. Finally, the developed method was successfully applied for the speciation of mercury in three environmental water samples.

  8. Ionic liquid-based air-assisted liquid-liquid microextraction followed by high performance liquid chromatography for the determination of five fungicides in juice samples.

    Science.gov (United States)

    You, Xiangwei; Chen, Xiaochu; Liu, Fengmao; Hou, Fan; Li, Yiqiang

    2018-01-15

    A novel and simple ionic liquid-based air-assisted liquid-liquid microextraction technique combined with high performance liquid chromatography was developed to analyze five fungicides in juice samples. In this method, ionic liquid was used instead of a volatile organic solvent as the extraction solvent. The emulsion was formed by pulling in and pushing out the mixture of aqueous sample solution and extraction solvent repeatedly using a 10mL glass syringe. No organic dispersive solvent was required. Under the optimized conditions, the limits of detection (LODs) were 0.4-1.8μgL -1 at a signal-to-noise ratio of 3. The limits of quantification (LOQs) set as the lowest spiking levels with acceptable recovery in juices were 10μgL -1 , except for fludioxonil whose LOQ was 20μgL -1 . The proposed method was applied to determine the target fungicides in juice samples, and acceptable recoveries ranging from 74.9% to 115.4% were achieved. Copyright © 2017. Published by Elsevier Ltd.

  9. Determination of Bisphenol A and Bisphenol AF in Vinegar samples by two-component mixed ionic liquid dispersive liquid-phase microextraction coupled with high performance liquid chromatography

    International Nuclear Information System (INIS)

    Tai, Z.; Liu, M.; Hu, X.; Yang, Y.

    2014-01-01

    This paper describes a sensitive and simple method for the determination of bisphenol A (BPA) and bisphenol AF (BPAF) in vinegar samples using two-component mixed ionic liquid dispersive liquid-phase microextraction coupled with high performance liquid chromatography. In this work, BPA and BPAF were selected as the model analytes, and two-component mixed ionic liquid included 1-butyl-3-methylimidazolium hexafluorophosphate ((C4Mim)PF6) and 1-hexyl-3-methyl-imidazolium hexafluorophosphate ((C6Mim)PF6) was used as the extraction solvent for the first time here. Parameters that affect the extraction efficiency were investigated. Under the optimum conditions, good linear relationships were discovered in the range of 1.0-100 micro g/L for BPA and 2.0-150 micro g/L for BPAF, respectively. Detection limits of proposed method based on the signal-to-noise ratio (S/N=3) were in the range of 0.15-0.38 micro g/L. The efficiencies of proposed method have also been demonstrated with spiked real vinegar samples. The result show this method/ procedure to be a more efficient approach for the determination of BPA and BPAF in real vinegar, presenting average recovery rate of 89.3-112 % and precision values of 0.9-13.5% (RSDs, n = 6). In comparison with traditional solid phase extraction procedures this method results in lower solvent consumption, low pollution levels, and faster sample preparation. (author)

  10. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  11. Performance evaluation of a thermal desorption/gas chromatographic/mass spectrometric method for the characterization of waste tank headspace samples

    International Nuclear Information System (INIS)

    Ma, C.Y.; Skeen, J.T.; Dindal, A.B.; Bayne, C.K.; Jenkins, R.A.

    1997-01-01

    A thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) method was validated for the determination of volatile organic compounds collected on carbonaceous triple sorbent traps and applied to characterize samples of headspace gases collected from underground nuclear waste storage tanks at the U.S. Department of Energy's Hanford site, in Richland, WA. Method validation used vapor-phase standards generated from 25 target analytes, including alkanes, alkyl alcohols, alkyl ketones, alkylated aromatics, and alkyl nitriles. The target analytes represent a group of compounds identified in one of the most problematic tanks. TD/GC/MS was carried out with modified injectors. Performance was characterized based on desorption efficiency, reproducibility, stability, and linearity of the calibration, method detection limits, preanalytical holding time, and quality control limits for surrogate standard recoveries. Desorption efficiencies were all greater than 82%, and the majority of the analytes (23 out of 25) had reproducibility values less than 24% near the method detection levels. The method was applied to the analysis of a total of 305 samples collected from the headspaces of 48 underground waste storge tanks. Quality control procedures were implemented to monitor sampling and TD/GC/MS method. 33 refs., 2 figs., 4 tabs

  12. Dispersive Liquid-Liquid Microextraction Combined with Ultrahigh Performance Liquid Chromatography/Tandem Mass Spectrometry for Determination of Organophosphate Esters in Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Haiying Luo

    2014-01-01

    Full Text Available A new technique was established to identify eight organophosphate esters (OPEs in this work. It utilised dispersive liquid-liquid microextraction in combination with ultrahigh performance liquid chromatography/tandem mass spectrometry. The type and volume of extraction solvents, dispersion agent, and amount of NaCl were optimized. The target analytes were detected in the range of 1.0–200 µg/L with correlation coefficients ranging from 0.9982 to 0.9998, and the detection limits of the analytes were ranged from 0.02 to 0.07 µg/L (S/N=3. The feasibility of this method was demonstrated by identifying OPEs in aqueous samples that exhibited spiked recoveries, which ranged between 48.7% and 58.3% for triethyl phosphate (TEP as well as between 85.9% and 113% for the other OPEs. The precision was ranged from 3.2% to 9.3% (n=6, and the interprecision was ranged from 2.6% to 12.3% (n=5. Only 2 of the 12 selected samples were tested to be positive for OPEs, and the total concentrations of OPEs in them were 1.1 and 1.6 µg/L, respectively. This method was confirmed to be simple, fast, and accurate for identifying OPEs in aqueous samples.

  13. Quantification of methionine and selenomethionine in biological samples using multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS).

    Science.gov (United States)

    Vu, Dai Long; Ranglová, Karolína; Hájek, Jan; Hrouzek, Pavel

    2018-05-01

    Quantification of selenated amino-acids currently relies on methods employing inductively coupled plasma mass spectrometry (ICP-MS). Although very accurate, these methods do not allow the simultaneous determination of standard amino-acids, hampering the comparison of the content of selenated versus non-selenated species such as methionine (Met) and selenomethionine (SeMet). This paper reports two approaches for the simultaneous quantification of Met and SeMet. In the first approach, standard enzymatic hydrolysis employing Protease XIV was applied for the preparation of samples. The second approach utilized methanesulfonic acid (MA) for the hydrolysis of samples, either in a reflux system or in a microwave oven, followed by derivatization with diethyl ethoxymethylenemalonate. The prepared samples were then analyzed by multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS). Both approaches provided platforms for the accurate determination of selenium/sulfur substitution rate in Met. Moreover the second approach also provided accurate simultaneous quantification of Met and SeMet with a low limit of detection, low limit of quantification and wide linearity range, comparable to the commonly used gas chromatography mass spectrometry (GC-MS) method or ICP-MS. The novel method was validated using certified reference material in conjunction with the GC-MS reference method. Copyright © 2018. Published by Elsevier B.V.

  14. Determination of phthalate esters from environmental water samples by micro-solid-phase extraction using TiO2 nanotube arrays before high-performance liquid chromatography.

    Science.gov (United States)

    Zhou, Qingxiang; Fang, Zhi; Liao, Xiangkun

    2015-07-01

    We describe a highly sensitive micro-solid-phase extraction method for the pre-concentration of six phthalate esters utilizing a TiO2 nanotube array coupled to high-performance liquid chromatography with a variable-wavelength ultraviolet visible detector. The selected phthalate esters included dimethyl phthalate, diethyl phthalate, dibutyl phthalate, butyl benzyl phthalate, bis(2-ethylhexyl)phthalate and dioctyl phthalate. The factors that would affect the enrichment, such as desorption solvent, sample pH, salting-out effect, extraction time and desorption time, were optimized. Under the optimum conditions, the linear range of the proposed method was 0.3-200 μg/L. The limits of detection were 0.04-0.2 μg/L (S/N = 3). The proposed method was successfully applied to the determination of six phthalate esters in water samples and satisfied spiked recoveries were achieved. These results indicated that the proposed method was appropriate for the determination of trace phthalate esters in environmental water samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Speciation of mercury in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Jia Xiaoyu; Han Yi; Liu Xinli; Duan Taicheng; Chen Hangting

    2011-01-01

    The dispersive liquid-liquid microextraction (DLLME) combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry for the speciation of mercury in water samples was described. Firstly methylmercury (MeHg + ) and mercury (Hg 2+ ) were complexed with sodium diethyldithiocarbamate, and then the complexes were extracted into carbon tetrachloride by using DLLME. Under the optimized conditions, the enrichment factors of 138 and 350 for MeHg + and Hg 2+ were obtained from only 5.00 mL sample solution. The detection limits of the analytes (as Hg) were 0.0076 ng mL -1 for MeHg + and 0.0014 ng mL -1 for Hg 2+ , respectively. The relative standard deviations for ten replicate measurements of 0.5 ng mL -1 MeHg + and Hg 2+ were 6.9% and 4.4%, respectively. Standard reference material of seawater (GBW(E)080042) was analyzed to verify the accuracy of the method and the results were in good agreement with the certified values. Finally, the developed method was successfully applied for the speciation of mercury in three environmental water samples.

  16. Automated dispersive liquid-liquid microextraction coupled to high performance liquid chromatography - cold vapour atomic fluorescence spectroscopy for the determination of mercury species in natural water samples.

    Science.gov (United States)

    Liu, Yao-Min; Zhang, Feng-Ping; Jiao, Bao-Yu; Rao, Jin-Yu; Leng, Geng

    2017-04-14

    An automated, home-constructed, and low cost dispersive liquid-liquid microextraction (DLLME) device that directly coupled to a high performance liquid chromatography (HPLC) - cold vapour atomic fluorescence spectroscopy (CVAFS) system was designed and developed for the determination of trace concentrations of methylmercury (MeHg + ), ethylmercury (EtHg + ) and inorganic mercury (Hg 2+ ) in natural waters. With a simple, miniaturized and efficient automated DLLME system, nanogram amounts of these mercury species were extracted from natural water samples and injected into a hyphenated HPLC-CVAFS for quantification. The complete analytical procedure, including chelation, extraction, phase separation, collection and injection of the extracts, as well as HPLC-CVAFS quantification, was automated. Key parameters, such as the type and volume of the chelation, extraction and dispersive solvent, aspiration speed, sample pH, salt effect and matrix effect, were thoroughly investigated. Under the optimum conditions, linear range was 10-1200ngL -1 for EtHg + and 5-450ngL -1 for MeHg + and Hg 2+ . Limits of detection were 3.0ngL -1 for EtHg + and 1.5ngL -1 for MeHg + and Hg 2+ . Reproducibility and recoveries were assessed by spiking three natural water samples with different Hg concentrations, giving recoveries from 88.4-96.1%, and relative standard deviations <5.1%. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Analytical performances of laser-induced micro-plasma of Al samples with single and double ultrashort pulses in air and with Ar-jet: A comparative study

    International Nuclear Information System (INIS)

    Semerok, A.; Dutouquet, C.

    2014-01-01

    Ultrashort pulse laser microablation coupled with optical emission spectroscopy was under study to obtain several micro-LIBS analytical features (shot-to-shot reproducibility, spectral line intensity and lifetime, calibration curves, detection limits). Laser microablation of Al matrix samples with known Cu- and Mg-concentrations was performed by single and double pulses of 50 fs and 1 ps pulse duration in air and with Ar-jet. The micro-LIBS analytical features obtained under different experimental conditions were characterized and compared. The highest shot-to-shot reproducibility and gain in plasma spectral line intensity were obtained with double pulses with Ar-jet for both 50 fs and 1 ps pulse durations. The best calibration curves were obtained with 1 ps pulse duration with Ar-jet. Micro-LIBS with ultrashort double pulses may find its effective application for surface elemental microcartography. - Highlights: • Analytical performances of micro-LIBS with ultrashort double pulses were studied. • The maximal line intensity gain of 20 was obtained with double pulses and Ar-jet. • LIBS gain was obtained without additional ablation of a sample by the second pulse. • LIBS properties were almost the same for both 50 fs and 1 ps pulses. • The micro-LIBS detection limit was around 35 ppm

  18. Evaluating Photographs as a Replacement for the In-Person Physical Examination of the Scored Patient-Generated Subjective Global Assessment in Elderly Hospital Patients.

    Science.gov (United States)

    Miller, Michelle; Thomas, Jolene; Suen, Jenni; Ong, De Sheng; Sharma, Yogesh

    2018-05-01

    Undernourished patients discharged from the hospital require follow-up; however, attendance at return visits is low. Teleconsultations may allow remote follow-up of undernourished patients; however, no valid method to remotely perform physical examination, a critical component of assessing nutritional status, exists. This study aims to compare agreement between photographs taken by trained dietitians and in-person physical examinations conducted by trained dietitians to rate the overall physical examination section of the scored Patient Generated Subjective Global Assessment (PG-SGA). Nested cross-sectional study. Adults aged ≥60 years, admitted to the general medicine unit at Flinders Medical Centre between March 2015 and March 2016, were eligible. All components of the PG-SGA and photographs of muscle and fat sites were collected from 192 participants either in the hospital or at their place of residence after discharge. Validity of photograph-based physical examination was determined by collecting photographic and PG-SGA data from each participant at one encounter by trained dietitians. A dietitian blinded to data collection later assessed de-identified photographs on a computer. Percentage agreement, weighted kappa agreement, sensitivity, and specificity between the photographs and in-person physical examinations were calculated. All data collected were included in the analysis. Overall, the photograph-based physical examination rating achieved a percentage agreement of 75.8% against the in-person assessment, with a weighted kappa agreement of 0.526 (95% CI: 0.416, 0.637; Pexamination by trained dietitians achieved a nearly acceptable percentage agreement, moderate weighted kappa, and fair sensitivity-specificity pair. Methodological refinement before field testing with other personnel may improve the agreement and accuracy of photograph-based physical examination. Copyright © 2018 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights

  19. Dual-cloud point extraction coupled to high performance liquid chromatography for simultaneous determination of trace sulfonamide antimicrobials in urine and water samples.

    Science.gov (United States)

    Nong, Chunyan; Niu, Zongliang; Li, Pengyao; Wang, Chunping; Li, Wanyu; Wen, Yingying

    2017-04-15

    Dual-cloud point extraction (dCPE) was successfully developed for simultaneous extraction of trace sulfonamides (SAs) including sulfamerazine (SMZ), sulfadoxin (SDX), sulfathiazole (STZ) in urine and water samples. Several parameters affecting the extraction were optimized, such as sample pH, concentration of Triton X-114, extraction temperature and time, centrifugation rate and time, back-extraction solution pH, back-extraction temperature and time, back-extraction centrifugation rate and time. High performance liquid chromatography (HPLC) was applied for the SAs analysis. Under the optimum extraction and detection conditions, successful separation of the SAs was achieved within 9min, and excellent analytical performances were attained. Good linear relationships (R 2 ≥0.9990) between peak area and concentration for SMZ and STZ were optimized from 0.02 to 10μg/mL, for SDX from 0.01 to 10μg/mL. Detection limits of 3.0-6.2ng/mL were achieved. Satisfactory recoveries ranging from 85 to 108% were determined with urine, lake and tap water spiked at 0.2, 0.5 and 1μg/mL, respectively, with relative standard deviations (RSDs, n=6) of 1.5-7.7%. This method was demonstrated to be convenient, rapid, cost-effective and environmentally benign, and could be used as an alternative tool to existing methods for analysing trace residues of SAs in urine and water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. A column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry method to determine anandamide and 2-arachidonoylglycerol in plasma samples.

    Science.gov (United States)

    Marchioni, Camila; de Souza, Israel Donizeti; Grecco, Caroline Fernandes; Crippa, José Alexandre; Tumas, Vitor; Queiroz, Maria Eugênia Costa

    2017-05-01

    This study reports a fast, sensitive, and selective column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to determine the endocannabinoids (eCBs), anandamide (AEA), and 2-arachidonoylglycerol (2-AG) in plasma samples. This bidimensional system used a restricted access media column (RP-8 ADS, 25 mm × 4 mm × 25 μM) in the first dimension and a core-shell Kinetex C18 (100 mm × 2, 1.7 mm × 1 μM) column in the second dimension, followed by detection in a mass spectrometer triple quadrupole (multiple reactions monitoring mode) operating in the positive mode. RP-8 ADS was used for trace enrichment of eCBs (reverse phase partitioning) and macromolecular matrix size exclusion; the core-shell column was used for the chromatographic separation. The column switching UHPLC-MS/MS method presented a linear range spanning from 0.1 ng mL -1 (LOQ) to 6 ng mL -1 for AEA and from 0.04 ng mL -1 (LOQ) to 10 ng mL -1 for 2-AG. Excluding the LLOQ values, the precision assays provided coefficients of variation lower than 8% and accuracy with relative standard error values lower than 14%. Neither carryover nor matrix effects were detected. This high-throughput column switching method compared to conventional methods is time saving as it involves fewer steps, consumes less solvent, and presents lower LLOQ. The column switching UHPLC-MS/MS method was successfully applied to determine AEA and 2-AG in plasma samples obtained from Alzheimer's disease patients. Graphical abstract A column switching ultra high-performance liquid chromatography-tandem mass spectrometry method using RP-8 ADS column and core shell column to determine endocannabinoids in plasma samples.