WorldWideScience

Sample records for perforated semiconductor neutron

  1. Non-streaming high-efficiency perforated semiconductor neutron detectors, methods of making same and measuring wand and detector modules utilizing same

    Science.gov (United States)

    McGregor, Douglas S.; Shultis, John K.; Rice, Blake B.; McNeil, Walter J.; Solomon, Clell J.; Patterson, Eric L.; Bellinger, Steven L.

    2010-12-21

    Non-streaming high-efficiency perforated semiconductor neutron detectors, method of making same and measuring wands and detector modules utilizing same are disclosed. The detectors have improved mechanical structure, flattened angular detector responses, and reduced leakage current. A plurality of such detectors can be assembled into imaging arrays, and can be used for neutron radiography, remote neutron sensing, cold neutron imaging, SNM monitoring, and various other applications.

  2. Use of pulsed neutron logging to evaluate perforation washing

    International Nuclear Information System (INIS)

    Dimon, C.A.

    1986-01-01

    This invention relates to the use of pulsed neutron logging techniques before and after perforation washing operations are performed to evaluate the degree of success of the perforation washing operations. Well logging operations of a type designed to respond to the difference between a formation immediately behind the well sheath and voids in the formation are performed both before and after the perforation washing operation. differences between the two resulting logs are then indicative of voids created by perforation washing. In a preferred embodiment, pulsed neutron logging is used as the logging technique, while a weighted brine having a high absorption cross section to pulsed neutrons is used as the perforation washing fluid

  3. Solid State Neutron Detector - A Review of Status

    International Nuclear Information System (INIS)

    Mukhopadhyay, Sanjoy

    2010-01-01

    The PowerPoint presentation was organized into the following areas: Driving forces behind research in semiconductor neutron devices; The (sup 3)He shortage crisis; Alternative detectors for neutron; Semiconductor diodes coated with boron; Perforated semiconductors for neutron detection; and, Three dimensional pillar and trench structured semiconductors.

  4. Semiconductor research with reactor neutrons

    International Nuclear Information System (INIS)

    Kimura, Itsuro

    1992-01-01

    Reactor neutrons play an important role for characterization of semiconductor materials as same as other advanced materials. On the other hand reactor neutrons bring about not only malignant irradiation effects called radiation damage, but also useful effects such as neutron transmutation doping and defect formation for opto-electronics. Research works on semiconductor materials with the reactor neutrons of the Kyoto University Reactor (KUR) are briefly reviewed. In this review, a stress is laid on the present author's works. (author)

  5. Layered semiconductor neutron detectors

    Science.gov (United States)

    Mao, Samuel S; Perry, Dale L

    2013-12-10

    Room temperature operating solid state hand held neutron detectors integrate one or more relatively thin layers of a high neutron interaction cross-section element or materials with semiconductor detectors. The high neutron interaction cross-section element (e.g., Gd, B or Li) or materials comprising at least one high neutron interaction cross-section element can be in the form of unstructured layers or micro- or nano-structured arrays. Such architecture provides high efficiency neutron detector devices by capturing substantially more carriers produced from high energy .alpha.-particles or .gamma.-photons generated by neutron interaction.

  6. Neutron detection using boron gallium nitride semiconductor material

    Directory of Open Access Journals (Sweden)

    Katsuhiro Atsumi

    2014-03-01

    Full Text Available In this study, we developed a new neutron-detection device using a boron gallium nitride (BGaN semiconductor in which the B atom acts as a neutron converter. BGaN and gallium nitride (GaN samples were grown by metal organic vapor phase epitaxy, and their radiation detection properties were evaluated. GaN exhibited good sensitivity to α-rays but poor sensitivity to γ-rays. Moreover, we confirmed that electrons were generated in the depletion layer under neutron irradiation. This resulted in a neutron-detection signal after α-rays were generated by the capture of neutrons by the B atoms. These results prove that BGaN is useful as a neutron-detecting semiconductor material.

  7. Dual-sided microstructured semiconductor neutron detectors (DSMSNDs)

    International Nuclear Information System (INIS)

    Fronk, Ryan G.; Bellinger, Steven L.; Henson, Luke C.; Ochs, Taylor R.; Smith, Colten T.; Kenneth Shultis, J.; McGregor, Douglas S.

    2015-01-01

    Microstructured semiconductor neutron detectors (MSNDs) have in recent years received much interest as high-efficiency replacements for thin-film-coated thermal neutron detectors. The basic device structure of the MSND involves micro-sized trenches that are etched into a vertically-oriented pvn-junction diode that are backfilled with a neutron converting material. Neutrons absorbed within the converting material induce fission of the parent nucleus, producing a pair of energetic charged-particle reaction products that can be counted by the diode. The MSND deep-etched microstructures produce good neutron-absorption and reaction-product counting efficiencies, offering a 10× improvement in intrinsic thermal neutron detection efficiency over thin-film-coated devices. Performance of present-day MSNDs are nearing theoretical limits; streaming paths between the conversion-material backfilled trenches, allow a considerable fraction of neutrons to pass undetected through the device. Dual-sided microstructured semiconductor neutron detectors (DSMSNDs) have been developed that utilize a complementary second set of trenches on the back-side of the device to count streaming neutrons. DSMSND devices are theoretically capable of greater than 80% intrinsic thermal neutron detection efficiency for a 1-mm thick device. The first such prototype DSMSNDs, presented here, have achieved 29.48±0.29% nearly 2× better than MSNDs with similar microstructure dimensions.

  8. Neutron and gamma irradiation effects on power semiconductor switches

    International Nuclear Information System (INIS)

    Schwarze, G.E.; Frasca, A.J.

    1990-01-01

    The performance characteristics of high power semiconductor switches subjected to high levels of neutron fluence and gamma dose must be known by the designer of the power conditioning, control and transmission subsystem of space nuclear power systems. Location and the allowable shielding mass budget will determine the level of radiation tolerance required by the switches to meet performance and reliability requirements. Neutron and gamma ray interactions with semiconductor materials and how these interactions affect the electrical and switching characteristics of solid state power switches is discussed. The experimental measurement system and radiation facilities are described. Experimental data showing the effects of neutron and gamma irradiation on the performance characteristics are given for power-type NPN bipolar junction transistors (BJTs), and metal-oxide-semiconductor field effect transistors (MOSFETs)

  9. Neutron and gamma irradiation effects on power semiconductor switches

    Science.gov (United States)

    Schwarze, G. E.; Frasca, A. J.

    1990-01-01

    The performance characteristics of high power semiconductor switches subjected to high levels of neutron fluence and gamma dose must be known by the designer of the power conditioning, control and transmission subsystem of space nuclear power systems. Location and the allowable shielding mass budget will determine the level of radiation tolerance required by the switches to meet performance and reliability requirements. Neutron and gamma ray interactions with semiconductor materials and how these interactions affect the electrical and switching characteristics of solid state power switches is discussed. The experimental measurement system and radiation facilities are described. Experimental data showing the effects of neutron and gamma irradiation on the performance characteristics are given for power-type NPN Bipolar Junction Transistors (BJTs), and Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs). BJTs show a rapid decrease in gain, blocking voltage, and storage time for neutron irradiation, and MOSFETs show a rapid decrease in the gate threshold voltage for gamma irradiation.

  10. Peculiarities of neutron interaction with boron containing semiconductors

    International Nuclear Information System (INIS)

    Didyk, A.Yu.; ); Hofman, A.; Institute of Atomic Energy, Otwock/Swierk; Vlasukova, L.A.

    2009-01-01

    The results of point defect creation calculation in B 4 C, BN and BP semiconductor single crystals irradiated in the fast neutron reactor IBR-2 are presented. It has been shown that during the thermal neutron interaction with light isotope boron atoms ( 10 B) the damage creation by means of fission nuclear reaction fragments (alpha particles and 7 Li recoil nuclei) exceeds the damage created by fast neutrons (E n > 0.1 MeV) by more than two orders of value. It has been concluded that such irradiation can create a well developed radiation defect structure in boron-containing crystals with nearly homogeneous vacancy depth distribution. This may be used in technological applications for more effective diffusion of impurities implanted at low energies or deposited onto the semiconductor surface. The developed homogeneous vacancy structure is very suitable for the radiation enhanced diffusion of electrically charged or neutral impurities from the surface into the technological depth of semiconductor devices under post irradiation treatment. (authors)

  11. Neutron detection with cryogenics and semiconductors

    International Nuclear Information System (INIS)

    Bell, Zane W.; Carpenter, D.A.; Cristy, S.S.; Lamberti, V.E.; Burger, Arnold; Woodfield, Brian F.; Niedermayr, Thomas; Dragos Hau, I.; Labov, Simon E.; Friedrich, Stephan; Geoffrey West, W.; Pohl, Kenneth R.; Berg, Lodewijk van den

    2005-01-01

    The common methods of neutron detection are reviewed with special attention paid to the application of cryogenics and semiconductors to the problem. The authors' work with LiF- and boron-based cryogenic instruments is described as well as the use of CdTe and HgI 2 for direct detection of neutrons. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  12. Semiconductor neutron detectors based on new types of materials

    International Nuclear Information System (INIS)

    Pochet, T.; Foulon, F.

    1993-01-01

    Neutron detection in hostile environments such as nuclear reactors has been performed using a new kind of semiconductor detector. So far, crystalline semiconductor detectors are not used in nuclear reactor instrumentation because of their sensitivity to radiation damage. For doses in excess of a few tens of kilo rads, radiation induced lattice defects produce a strong loss in the standard semiconductor detector performances. In the last few years, new semiconductor materials having amorphous or polycrystalline structures such as silicon, silicon carbide or CVD diamond, became available. These semiconductors, produced by Chemical Vapor Deposition, come in the form of thin layers being typically a few tens of micron thick. Their crystalline structure is particularly resistant to radiation damage up to a few Mrads but prevent the material use in spectrometry measurements. Nevertheless, these detectors, working in a counting mode, are suitable for the detection of alpha particles produced by the neutron capture reaction with boron. Such thin film detectors have a very poor sensitivity to γ-ray background. Furthermore, they are easier and cheaper to implement than current neutron gas counters. Preliminary results obtained with diamond and amorphous silicon diodes exposed to α particles are presented. (authors). 7 figs., 3 tabs., 11 refs

  13. Measurement of neutron flux by semiconductor detector; Merenje raspodele neutronskog fluksa poluprovodnickim detektorom

    Energy Technology Data Exchange (ETDEWEB)

    Obradovic, D; Bosevski, T [The Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1965-07-01

    Using semiconductor detectors for measuring the neutron flux distribution is considered suitable and faster than using activation foils. Results of radial neutron flux distribution obtained by semiconductor detectors are presented.

  14. Energy response of neutron area monitor with silicon semiconductor detector

    International Nuclear Information System (INIS)

    Kitaguchi, Hiroshi; Izumi, Sigeru; Kobayashi, Kaoru; Kaihara, Akihisa; Nakamura, Takashi.

    1993-01-01

    A prototype neutron area monitor with a silicon semiconductor detector has been developed which has the energy response of 1 cm dose equivalent recommended by the ICRP-26. Boron and proton radiators are coated on the surface of the silicon semiconductor detector. The detector is set at the center of a cylindrical polyethylene moderator. This moderator is covered by a porous cadmium board which serves as the thermal neutron absorber. Neutrons are detected as α-particles generated by the nuclear reaction 10 B(n,α) 7 Li and as recoil protons generated by the interaction of fast neutrons with hydrogen. The neutron energy response of the monitor was measured using thermal neutrons and monoenergetic fast neutrons generated by an accelerator. The response was consistent with the 1 cm dose equivalent response required for the monitor within ±34% in the range of 0.025 - 15 Mev. (author)

  15. A semiconductor counter telescope for neutron reaction studies

    Energy Technology Data Exchange (ETDEWEB)

    Lalovic, B I; Ajdacic, V S [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1963-12-15

    A counter telescope consisting of two or three semiconductor counters for {delta}E/{delta}x vs. E analysis was made for studying nuclear reactions induced by 14.4 MeV neutrons. Various factors important for the telescope performance are discussed in details and some solutions for getting an optimum resolution and a low background are given. Protons, deuterons and alpha particles resulting from scattering and reactions of 14.4 MeV neutrons on deuterium, tritium, praseodymium and niobium were detected, and pulses from the counters recorded on a two-dimensional analyzer. These experiments have shown that the telescope compares favorably with other types of telescopes with regards to the upper limit of neutron flux which can be used, (DELTADELTA)x and E resolution, versatility and compactness (author)

  16. Semiconductor dosimetry system for gamma and neutron radiation

    International Nuclear Information System (INIS)

    Savic, Z.; Pavlovic, Z.

    1995-01-01

    The semiconductor dosimetry system for gamma and neutron radiation based on pMOS transistor and PIN diode is described. It is intended for tactical or accidental personal dosimetry. The production steps are given. The temperature, dose and time (fading) response are reported. Hardware and software requirements which are needed for obtaining the desired measurement error are pointed. (author)

  17. Neutron, gamma ray and post-irradiation thermal annealing effects on power semiconductor switches

    Science.gov (United States)

    Schwarze, G. E.; Frasca, A. J.

    1991-01-01

    The effects of neutron and gamma rays on the electrical and switching characteristics of power semiconductor switches must be known and understood by the designer of the power conditioning, control, and transmission subsystem of space nuclear power systems. The SP-100 radiation requirements at 25 m from the nuclear source are a neutron fluence of 10(exp 13) n/sq cm and a gamma dose of 0.5 Mrads. Experimental data showing the effects of neutrons and gamma rays on the performance characteristics of power-type NPN Bipolar Junction Transistors (BJTs), Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs), and Static Induction Transistors (SITs) are presented. These three types of devices were tested at radiation levels which met or exceeded the SP-100 requirements. For the SP-100 radiation requirements, the BJTs were found to be most sensitive to neutrons, the MOSFETs were most sensitive to gamma rays, and the SITs were only slightly sensitive to neutrons. Post-irradiation thermal anneals at 300 K and up to 425 K were done on these devices and the effectiveness of these anneals are also discussed.

  18. Neutron, gamma ray and post-irradiation thermal annealing effects on power semiconductor switches

    International Nuclear Information System (INIS)

    Schwarze, G.E.; Frasca, A.J.

    1994-01-01

    The effects of neutrons and gamma rays on the electrical and switching characteristics of power semiconductor switches must be known and understood by the designer of the power conditioning, control, and transmission subsystem of space nuclear power systems. The SP-100 radiation requirements at 25 m from the nuclear source are a neutron fluence of 10 13 n/cm 2 and a gamma dose of 0.5 Mrads. Experimental data showing the effects of neutrons and gamma rays on the performance characteristics of power-type NPN Bipolar Junction Transistors (BJTs), Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs), and Static Induction Transistors (SITs) are given in this paper. These three types of devices were tested at radiation levels which met or exceeded the SP-100 requirements. For the SP-100 radiation requirements, the BJTs were found to be most sensitive to neutrons, the MOSFETs were most sensitive to gamma rays, and the SITs were only slightly sensitive to neutrons. Post-irradiation thermal anneals at 300 K and up to 425 K were done on these devices and the effectiveness of these anneals are also discussed

  19. Monte Carlo simulations of the particle transport in semiconductor detectors of fast neutrons

    International Nuclear Information System (INIS)

    Sedlačková, Katarína; Zaťko, Bohumír; Šagátová, Andrea; Nečas, Vladimír

    2013-01-01

    Several Monte Carlo all-particle transport codes are under active development around the world. In this paper we focused on the capabilities of the MCNPX code (Monte Carlo N-Particle eXtended) to follow the particle transport in semiconductor detector of fast neutrons. Semiconductor detector based on semi-insulating GaAs was the object of our investigation. As converter material capable to produce charged particles from the (n, p) interaction, a high-density polyethylene (HDPE) was employed. As the source of fast neutrons, the 239 Pu–Be neutron source was used in the model. The simulations were performed using the MCNPX code which makes possible to track not only neutrons but also recoiled protons at all interesting energies. Hence, the MCNPX code enables seamless particle transport and no other computer program is needed to process the particle transport. The determination of the optimal thickness of the conversion layer and the minimum thickness of the active region of semiconductor detector as well as the energy spectra simulation were the principal goals of the computer modeling. Theoretical detector responses showed that the best detection efficiency can be achieved for 500 μm thick HDPE converter layer. The minimum detector active region thickness has been estimated to be about 400 μm. -- Highlights: ► Application of the MCNPX code for fast neutron detector design is demonstrated. ► Simulations of the particle transport through conversion film of HDPE are presented. ► Simulations of the particle transport through detector active region are presented. ► The optimal thickness of the HDPE conversion film has been calculated. ► Detection efficiency of 0.135% was reached for 500 μm thick HDPE conversion film

  20. Measurement of fast neutron spectra inside reactors with a Li{sup 6} semiconductor counter spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Ajdacic, V S; Lalovic, B I; Petrovic, B P [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1963-12-15

    The possibility of using the Li{sup 6} semiconductor counter spectrometer for measuring fast neutron spectra inside reactors has been investigated in details and some solutions of the difficulties associated with the high interference of thermal neutrons in well-moderated reactors are suggested and checked experimentally (author)

  1. Calculation of neutron-induced single-event upset cross sections for semiconductor memory devices

    International Nuclear Information System (INIS)

    Ikeuchi, Taketo; Watanabe, Yukinobu; Nakashima, Hideki; Sun, Weili

    2001-01-01

    Neutron-induced single-event upset (SEU) cross sections for semiconductor memory devices are calculated by the Burst Generation Rate (BGR) method using LA150 data and QMD calculation in the neutron energy range between 20 MeV and 10 GeV. The calculated results are compared with the measured SEU cross sections for energies up to 160 MeV, and the validity of the calculation method and the nuclear data used is verified. The kind of reaction products and the neutron energy range that have the most effect on SEU are discussed. (author)

  2. Dosimetric evaluation of semiconductor detectors for application in neutron dosimetry and microdosimetry in nuclear reactor and radiosurgical facilities

    International Nuclear Information System (INIS)

    Cardenas, Jose Patricio Nahuel

    2010-01-01

    The main objective of this research is the dosimetric evaluation of semiconductor components (surface barrier detectors and PIN photodiodes) for applications in dose equivalent measurements on low dose fields (fast and thermal fluxes) using an AmBe neutron source, the IEA-R1 reactor neutrongraphy facility (epithermal and thermal fluxes) and the Critical Unit facility IPEN/MB-01 (fast fluxes). As moderator compound to fast neutrons flux from the AmBe source was used paraffin and boron and polyethylene as converter for thermal and fast neutrons measurements. The resulting fluxes were used to the irradiation of semiconductor components (SSB - Surface Barrier Detector and PIN photodiodes). A mixed converter made of a borated polyethylene foil (Kodak) was also used. Monte Carlo simulation methodology was employed to evaluate analytically the optimal paraffin thickness. The obtained results were similar to the experimental data and allowed the evaluation of emerging neutron flux from moderator, as well as the fast neutron flux reaching the polyethylene covering the semiconductor sensitive surface. Gamma radiation levels were evaluated covering the whole detector with cadmium foil 1 mm thick, allowing thermal neutrons blockage and gamma radiation measurements. The IPEN/MB-01 facility was employed to evaluate the detector response for high neutron flux. The results were in good agreement with other studies published. Using the obtained spectra an approach to dose equivalent calculation was established. (author)

  3. Flux distribution by neutrons semi-conductors detectors during the startup of the EL4 reactor

    International Nuclear Information System (INIS)

    Fuster, S.; Tarabella, A.

    1967-01-01

    The Cea developed neutron semi-conductors detectors which allows a quasi-instantaneous monitoring of neutrons flux distribution, when placed in a reactor during the tests. These detectors have been experimented in the EL4 reactor. The experiment and the results are presented and compared with reference mappings. (A.L.B.)

  4. Properties of SiC semiconductor detector of fast neutrons investigated using MCNPX code

    International Nuclear Information System (INIS)

    Sedlakova, K.; Sagatova, A.; Necas, V.; Zatko, B.

    2013-01-01

    The potential of silicon carbide (SiC) for use in semiconductor nuclear radiation detectors has been long recognized. The wide bandgap of SiC (3.25 eV for 4H-SiC polytype) compared to that for more conventionally used semiconductors, such as silicon (1.12 eV) and germanium (0.67 eV), makes SiC an attractive semiconductor for use in high dose rate and high ionization nuclear environments. The present work focused on the simulation of particle transport in SiC detectors of fast neutrons using statistical analysis of Monte Carlo radiation transport code MCNPX. Its possibilities in detector design and optimization are presented.(authors)

  5. Neutron measurements inside reactors with semiconductor counters; Apsolutno merenje neutronskih flukseva u jezgru reaktora RA visokim snagama

    Energy Technology Data Exchange (ETDEWEB)

    Ajdacic, V; Lalovic, B; Barucija, M; Petrovic, B [Institute of Nuclear Sciences Boris Kidric, Laboratorija za fiziku i dinamiku reaktora, Vinca, Beograd (Serbia and Montenegro)

    1964-06-15

    A method of absolute in-core measurement of high neutron fluxes inside reactors operating in the megawatt region is described. In this method a semiconductor counter observes particles coming from neutron induced reactions in a target placed inside the reactor core through a long evacuated aluminum tube. The paper deals with factors which influence the accuracy of the method. Possible use of the long- tube method for neutron flux measurements in advanced reactors with neutron flux of 10{sup 15}-10{sup 16} n/cm{sup 2} sec is also discussed. The possibility of using the Li{sup 6} semiconductor counter spectrometer for measuring fast neutron spectra inside the zero power reactor at Vinca has been investigated. Great difficulties associated with the high interference of thermal neutrons have been encountered. The thermal neutron interference is almost completely suppressed by a new detector-target arrangement, in which only those products of the Li{sup 6} (n,alpha)T reactions whose mutual angle of emission is different from 180 deg are detected in coincidence. Resolution of the spectrometer as a function of the reactor power and correction factors of the spectrometer efficiency for various neutron energies are presented (author)

  6. Development of a semiconductor neutron dosimeter with a PIN diode

    International Nuclear Information System (INIS)

    Kim, Seungho; Lee, Namho; Cho, Jaiwan; Youk, Geunuck

    2004-01-01

    When a Si PIN diode is exposed to fast neutrons, it produces displacement in Si lattice structure of the diode. Defects induced from structural dislocation become effective recombination centers for carriers which pass through the base of a PIN diode. Hence, increasing the resistivity of the diode decreases the current for the applied forward voltage. This paper involves the development of a neutron sensor based on the phenomena of the displacement effect damaged by neutron exposure. The neutron effect on the semiconductor was analyzed, and multi PIN diode arrays with various intrinsic layer (I layer) thicknesses and cross sections were fabricated. Under irradiation tests with a neutron beam, the manufactured diodes have good characteristics of linearity in a neutron irradiation experiment and give results that the increase of thickness of I layer and the decrease of the cross-section of the PIN diodes improve the sensitivity. Newly developed PIN diodes with a thicker I layer and various cross sections were retested and showed the best neutron sensitivity in the condition that the I layer thickness was similar to the length of a side of the cross-section. On the basis of two test results, final PIN diodes with a rectangular shape were manufactured and the characteristics for neutron detectors were analyzed through the neutron beam test using the on-line electronic dosimetry system. The developed PIN diode shows a good linearity to absorbed dose in the range of 0 to 1,000cGy (Tissue) and its neutron sensitivity is 13 mV/cGy at a constant current of 5 mA, that is three higher than that of similar commercially developed neutron detectors. Moreover the device shows less dependency on the orientation of the neutron beam and a considerable stability in an annealing test for a long period. (author)

  7. Second International Conference on Neutron Transmutation Doping in Semiconductors

    CERN Document Server

    Neutron Transmutation Doping in Semiconductors

    1979-01-01

    This volume contains the invited and contributed papers presented at the Second International Conference on Neutron Transmutation Doping in Semiconductors held April 23-26, 1978 at the University of Missouri-Columbia. The first "testing of the waters" symposium on this subject was organized by John Cleland and Dick Wood of the Solid-State Division of Oak Ridge National Laboratory in April of 1976, just one year after NTD-silicon appeared on the marketplace. Since this first meeting, NTD-silicon has become established as the starting material for the power device industry and reactor irradiations are now measured in tens of tons of material per annum making NTD processing the largest radiation effects technology in the semiconductor industry. Since the first conference at Oak Ridge, new applications and irradiation techniques have developed. Interest in a second con­ ference and in publishing the proceedings has been extremely high. The second conference at the University of Missouri was attended by 114 perso...

  8. Measurement of neutron flux distribution by semiconductor detector

    International Nuclear Information System (INIS)

    Obradovic, D.; Bosevski, T.

    1964-01-01

    Application of semiconductor detectors for measuring neutron flux distribution is about 10 times faster than measurements by activation foils and demands significantly lower reactor power. Following corrections are avoided: mass of activation foils which influences the self shielding, nuclear decay during activity measurements; counter dead-time. It is possible to control the measured data during experiment and repeat measurements if needed. Precision of the measurement is higher since it is possible to choose the wanted statistics. The method described in this paper is applied for measurements at the RB reactor. It is concluded that the method is suitable for fast measurements but the activation analysis is still indispensable

  9. Neutron scattering studies of a dilute magnetic semiconductor: Cd1-xMnxTe

    DEFF Research Database (Denmark)

    Steigenberger, Ursula; Lebech, Bente; Galazka, Robert R.

    1986-01-01

    The development of the magnetic ordering in the magnetic semiconductor Cd1-xMnxTe was investigated by elastic neutron scattering. A detailed study of the correlation length and the intensity as a function of temperature, direction in reciprocal space and concentration of the magnetic ions has been...

  10. Polycrystalline semiconductor probes for monitoring the density distribution of an intense thermal neutron flux in nuclear reactors

    International Nuclear Information System (INIS)

    Graul, J.; Mueller, R.G.; Wagner, E.

    1975-05-01

    The applicability of semiconductor detectors for high thermal neutron flux densities is theoretically estimated and experimentally examined. For good thermal stability and low radiation capture rate silicon carbide is used as semiconductor material, produced in polycristalline layers to achieve high radiation resistance. The relations between crystallinity, photoelectric sensitivity and radiation resistance are shown. The radiation resistance of polycrystalline SiC-probes is approximately 100 times greater than that of conventional single crystal radiation detectors. For thermal neutron measurement they can be used in the flux range of approx. 10 10 13 (cm -2 sec -1 ) with operation times of 1.6 a >= tsub(b,max) >= 30 d, resp. (orig.) [de

  11. Nuclear data relevant to single event upsets in semiconductor memories induced by cosmic-ray neutrons and protons

    International Nuclear Information System (INIS)

    Watanabe, Yukinobu

    2008-01-01

    The role of nuclear data is examined in the study of single event upset (SEU) phenomena in semiconductor memories caused by cosmic-ray neutrons and protons. Neutron and proton SEU cross sections are calculated with a simplified semi-empirical model using experimental heavy-ion SEU cross-sections and a dedicated database of neutron and proton induced reactions on 28 Si. Some impacts of the nuclear reaction data on SEU simulation are analyzed by investigating relative contribution of secondary ions and neutron elastic scattering to SEU and influence of simultaneous multiple ions emission on SEU. (author)

  12. Neutron activation determination of phosphorus in semiconductor materials

    International Nuclear Information System (INIS)

    Verevkin, G.V.; Gil'bert, Eh.N.; Gol'dshtejn, M.M.; Yudelevich, I.G.; Yurchenko, V.K.

    1976-01-01

    The solvent extraction of molybdophosphoric acid (MPA) with benzene and dichloroethane solutions of dioctylsulphoxide has been studied. A neutron-activation method has been worked out of determining phosphorus in semiconductor silicon, high purity gallium, and homoepitaxial films of gallium arsenide. The method is based on separation of radiochemically pure phosphorus in the form of MPA by extraction with 0.2 M solution of dioctylsulphoxide in benzene and measurement of 32 P activity on a liquid scintillation spectrometer. The method makes it possible to determine phosphorus in the materials enumerated with a limit of detection of 1.9x10 -10 g and a relative standard deviation of not more than 0.05

  13. Influence of nuclear cross section data at efficiency calculation of the 3He semiconductor neutron spectrometer

    International Nuclear Information System (INIS)

    Avdic, S.; Pesic, M.

    1992-01-01

    The ORTEC 580 Neutron Spectrometer system contains a detector unit in diode coincidence arrangement for measurement of fast neutron spectrum in the energy range from 1 MeV to 14 MeV. Numerical code HE3 for computation of semiconductor 3 He detector efficiency in a collimated neutron beam is based on analytical method in infinite diode approximation and Monte Carlo method for real spectrometer geometry. Calculations are performed in the first collision approximation in the detector active volume including evaluation of correction factors. Accuracy of relative detector efficiency calculation is improved by using neutron cross section from nuclear library ENDF/B-6. (author)

  14. Semiconductor Thermal Neutron Detector

    Directory of Open Access Journals (Sweden)

    Toru Aoki

    2014-02-01

    Full Text Available The  CdTe  and  GaN  detector  with  a  Gd  converter  have  been developed  and  investigated  as  a  neutron  detector  for neutron  imaging.  The  fabricated  Gd/CdTe  detector  with  the  25  mm  thick  Gd  was  designed  on  the  basis  of  simulation results  of  thermal  neutron  detection  efficiency  and  spatial  resolution.  The  Gd/CdTe  detector  shows  the  detection  of neutron  capture  gamma  ray  emission  in  the  155Gd(n,  g156Gd,  157Gd(n,  g158Gd  and  113Cd(n,  g114Cd  reactions  and characteristic X-ray emissions due to conversion-electrons generated inside the Gd film. The observed efficient thermal neutron detection with the Gd/CdTe detector shows its promise in neutron radiography application. Moreover, a BGaN detector has also investigated to separate neutron signal from gamma-ray clearly. 

  15. Comparison of Cadmium-Zinc-Telluride semiconductor and Yttrium-Aluminum-Perovskite scintillator as photon detectors for epithermal neutron spectroscopy

    International Nuclear Information System (INIS)

    Tardocchi, M.; Pietropaolo, A.; Andreani, C.; Gorini, G.; Imberti, S.; Perelli-Cippo, E.; Senesi, R.; Rhodes, N.; Schooneveld, E.M.

    2006-01-01

    The range of applications of epithermal neutron scattering experiments has been recently extended by the development of the Resonance Detector. In a Resonance Detector, resonant neutron absorption in an analyzer foil results in prompt emission of X- and γ-rays which are detected by a photon counter. Several combinations of analyzer foils and photon detectors have been studied and tested over the years and best results have been obtained with the combination of a natural uranium and (i) Cadmium-Zinc-Telluride (CZT) semiconductor (ii) Yttrium-Aluminum-Perovskite (YAP) scintillators. Here we compare the performance of the CZT semiconductor and YAP scintillator as Resonance Detector units. Two Resonance Detector prototypes made of natural uranium foil viewed by CZT and YAP were tested on the VESUVIO spectrometer at the ISIS spallation neutron source. The results show that both YAP and CZT can be used to detect epithermal neutrons in the energy range from 1 up to 66 eV. It was found that the signal-to-background ratio of the measurement can significantly be improved by raising the lower level discrimination threshold on the γ energy to about 600 keV. The advantages/disadvantages of the choice of a Resonance Detector based on YAP or CZT are discussed together with some potential applications

  16. Design and operation of a 2-D thin-film semiconductor neutron detector array for use as a beamport monitor

    International Nuclear Information System (INIS)

    Unruh, Troy C.; Bellinger, Steven L.; Huddleston, David E.; McNeil, Walter J.; Patterson, Eric; Sobering, Tim J.; McGregor, Douglas S.

    2009-01-01

    Silicon-based diodes coated with a thin film of neutron reactive materials have been shown to produce excellent low-efficiency neutron detectors. This work employs the same technology, but groups 25 equally sized and spaced diodes on a single 29 mm by 29 mm substrate. A 5x5 array was fabricated and coated with a thin film of 6 LiF for use as a low-efficiency neutron beam monitor. The 5x5 neutron detector array is coupled to an array of amplifiers, allowing the response to be interpreted using a LabVIEW FPGA. The 5x5 array has been characterized in a diffracted neutron beam. This work is a part of on-going research to develop various designs of high- and low-efficiency semiconductor neutron detectors.

  17. Microstructured silicon neutron detectors for security applications

    International Nuclear Information System (INIS)

    Esteban, S; Fleta, C; Jumilla, C; Pellegrini, G; Quirion, D; Rodriguez, J; Lozano, M; Guardiola, C

    2014-01-01

    In this paper we present the design and performance of a perforated thermal neutron silicon detector with a 6 LiF neutron converter. This device was manufactured within the REWARD project workplace whose aim is to develop and enhance technologies for the detection of nuclear and radiological materials. The sensor perforated structure results in a higher efficiency than that obtained with an equivalent planar sensor. The detectors were tested in a thermal neutron beam at the nuclear reactor at the Instituto Superior Técnico in Lisbon and the intrinsic detection efficiency for thermal neutrons and the gamma sensitivity were obtained. The Geant4 Monte Carlo code was used to simulate the experimental conditions, i.e. thermal neutron beam and the whole detector geometry. An intrinsic thermal neutron detection efficiency of 8.6%±0.4% with a discrimination setting of 450 keV was measured

  18. neutron-Induced Failures in semiconductor Devices

    Energy Technology Data Exchange (ETDEWEB)

    Wender, Stephen Arthur [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-13

    Single Event Effects are a very significant failure mode in modern semiconductor devices that may limit their reliability. Accelerated testing is important for semiconductor industry. Considerable more work is needed in this field to mitigate the problem. Mitigation of this problem will probably come from Physicists and Electrical Engineers working together

  19. Neutron-Induced Failures in Semiconductor Devices

    Energy Technology Data Exchange (ETDEWEB)

    Wender, Stephen Arthur [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-04-06

    This slide presentation explores single event effect, environmental neutron flux, system response, the Los Alamos Neutron Science Center (LANSCE) neutron testing facility, examples of SEE measurements, and recent interest in thermal neutrons.

  20. Typhoid Intestinal Perforation: 24 Perforations in One Patient

    African Journals Online (AJOL)

    Intestinal perforation is a common cause of peritonitis necessitating emergency surgical intervention. Perforation ... Mortality rates of typhoid intestinal perforation (TIP) cases are ... may be obscured clinical features with resultant delays in.

  1. The Los Alamos Neutron Science Center Spallation Neutron Sources

    International Nuclear Information System (INIS)

    Nowicki, Suzanne F.; Wender, Stephen A.; Mocko, Michael

    2017-01-01

    The Los Alamos Neutron Science Center (LANSCE) provides the scientific community with intense sources of neutrons, which can be used to perform experiments supporting civilian and national security research. These measurements include nuclear physics experiments for the defense program, basic science, and the radiation effect programs. This paper focuses on the radiation effects program, which involves mostly accelerated testing of semiconductor parts. When cosmic rays strike the earth's atmosphere, they cause nuclear reactions with elements in the air and produce a wide range of energetic particles. Because neutrons are uncharged, they can reach aircraft altitudes and sea level. These neutrons are thought to be the most important threat to semiconductor devices and integrated circuits. The best way to determine the failure rate due to these neutrons is to measure the failure rate in a neutron source that has the same spectrum as those produced by cosmic rays. Los Alamos has a high-energy and a low-energy neutron source for semiconductor testing. Both are driven by the 800-MeV proton beam from the LANSCE accelerator. The high-energy neutron source at the Weapons Neutron Research (WNR) facility uses a bare target that is designed to produce fast neutrons with energies from 100 keV to almost 800 MeV. The measured neutron energy distribution from WNR is very similar to that of the cosmic-ray-induced neutrons in the atmosphere. However, the flux provided at the WNR facility is typically 5×107 times more intense than the flux of the cosmic-ray-induced neutrons. This intense neutron flux allows testing at greatly accelerated rates. An irradiation test of less than an hour is equivalent to many years of neutron exposure due to cosmic-ray neutrons. The low-energy neutron source is located at the Lujan Neutron Scattering Center. It is based on a moderated source that provides useful neutrons from subthermal energies to ~100 keV. The characteristics of these sources

  2. The Los Alamos Neutron Science Center Spallation Neutron Sources

    Science.gov (United States)

    Nowicki, Suzanne F.; Wender, Stephen A.; Mocko, Michael

    The Los Alamos Neutron Science Center (LANSCE) provides the scientific community with intense sources of neutrons, which can be used to perform experiments supporting civilian and national security research. These measurements include nuclear physics experiments for the defense program, basic science, and the radiation effect programs. This paper focuses on the radiation effects program, which involves mostly accelerated testing of semiconductor parts. When cosmic rays strike the earth's atmosphere, they cause nuclear reactions with elements in the air and produce a wide range of energetic particles. Because neutrons are uncharged, they can reach aircraft altitudes and sea level. These neutrons are thought to be the most important threat to semiconductor devices and integrated circuits. The best way to determine the failure rate due to these neutrons is to measure the failure rate in a neutron source that has the same spectrum as those produced by cosmic rays. Los Alamos has a high-energy and a low-energy neutron source for semiconductor testing. Both are driven by the 800-MeV proton beam from the LANSCE accelerator. The high-energy neutron source at the Weapons Neutron Research (WNR) facility uses a bare target that is designed to produce fast neutrons with energies from 100 keV to almost 800 MeV. The measured neutron energy distribution from WNR is very similar to that of the cosmic-ray-induced neutrons in the atmosphere. However, the flux provided at the WNR facility is typically 5×107 times more intense than the flux of the cosmic-ray-induced neutrons. This intense neutron flux allows testing at greatly accelerated rates. An irradiation test of less than an hour is equivalent to many years of neutron exposure due to cosmic-ray neutrons. The low-energy neutron source is located at the Lujan Neutron Scattering Center. It is based on a moderated source that provides useful neutrons from subthermal energies to ∼100 keV. The characteristics of these sources, and

  3. Proceedings of the specialist research meetings on semiconductors with research reactors

    International Nuclear Information System (INIS)

    Kawakubo, Tetsuya; Kimura, Itsuro

    1987-01-01

    The meeting was proceeded divided five sessions, (I) structure analysis of semiconductors with neutrons, (II) structure analysis with positrons, (III) neutron transmutation doping and radiation damage, (IV) discussion on the way of research on semiconductors in the Institute. (author)

  4. Absolute measurement of neutron fluxes inside the reactor core

    International Nuclear Information System (INIS)

    Ajdacic, S. V.

    1964-10-01

    The subject of this work is the development and study of two methods of neutron measurements in nuclear reactors, the new method of high neutron flux measurements and the Li 6 -semiconductor neutron spectrometer. This work is presented in four sections: Section I. The introduction explains the need for neutron measurements in reactors. A critical survey is given of the existing methods of high neutron flux measurement and methods of fast neutron spectrum determination. Section II. Theoretical basis of the work of semiconductor counters and their most important characteristics are given. Section III. The main point of this section is in presenting the basis of the new method which the author developed, i.e., the long-tube method, and the results obtained by it, with particular emphasis on absolute measurement of high neutron fluxes. Advantages and limitations of this method are discussed in details at the end of this section. Section IV. A comparison of the existing semiconductor neutron spectrometers is made and their advantages and shortcomings underlined. A critical analysis of the obtained results with the Li 6 -semiconductor spectrometer with plane geometry is given. A new type of Li 6 -semiconductor spectrometer is described, its characteristics experimentally determined, and a comparison of it with a classical Li 6 -spectrometer made (author)

  5. Pedicled perforator flaps

    DEFF Research Database (Denmark)

    Demirtas, Yener; Ozturk, Nuray; Kelahmetoglu, Osman

    2009-01-01

    Described in this study is a surgical concept that supports the "consider and use a pedicled perforator flap whenever possible and indicated" approach to reconstruct a particular skin defect. The operation is entirely free-style; the only principle is to obtain a pedicled perforator flap...... to reconstruct the defect. The perforators are marked with a hand-held Doppler probe and multiple flaps are designed. The appropriate flap is elevated after identifying the perforator(s). Dissection of the perforator(s) or complete incision of the flap margins are not mandatory if the flap is mobilized...... adequately to cover the defect. Defects measuring 3 x 3 cm up to 20 x 20 cm at diverse locations were successfully reconstructed in 20 of 21 patients with 26 flaps. Pedicled perforator flaps offer us reliable and satisfactory results of reconstruction at different anatomic territories of the body. It sounds...

  6. Absolute measurement of neutron fluxes inside the reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Ajdacic, S V [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1964-10-15

    The subject of this work is the development and study of two methods of neutron measurements in nuclear reactors, the new method of high neutron flux measurements and the Li{sup 6}-semiconductor neutron spectrometer. This work is presented in four sections: Section I. The introduction explains the need for neutron measurements in reactors. A critical survey is given of the existing methods of high neutron flux measurement and methods of fast neutron spectrum determination. Section II. Theoretical basis of the work of semiconductor counters and their most important characteristics are given. Section III. The main point of this section is in presenting the basis of the new method which the author developed, i.e., the long-tube method, and the results obtained by it, with particular emphasis on absolute measurement of high neutron fluxes. Advantages and limitations of this method are discussed in details at the end of this section. Section IV. A comparison of the existing semiconductor neutron spectrometers is made and their advantages and shortcomings underlined. A critical analysis of the obtained results with the Li{sup 6}-semiconductor spectrometer with plane geometry is given. A new type of Li{sup 6}-semiconductor spectrometer is described, its characteristics experimentally determined, and a comparison of it with a classical Li{sup 6}-spectrometer made (author)

  7. Measurement of neutron flux distribution by semiconductor detector; merenje raspodele neutronskog fluksa poluprovodnickim detektorom

    Energy Technology Data Exchange (ETDEWEB)

    Obradovic, D; Bosevski, T [Institut za nuklearne nauke Boris Kidric, Vinca, Beograd (Yugoslavia)

    1964-07-01

    Application of semiconductor detectors for measuring neutron flux distribution is about 10 times faster than measurements by activation foils and demands significantly lower reactor power. Following corrections are avoided: mass of activation foils which influences the self shielding, nuclear decay during activity measurements; counter dead-time. It is possible to control the measured data during experiment and repeat measurements if needed. Precision of the measurement is higher since it is possible to choose the wanted statistics. The method described in this paper is applied for measurements at the RB reactor. It is concluded that the method is suitable for fast measurements but the activation analysis is still indispensable.

  8. Differentiating perforated from non-perforated appendicitis on contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Rosenbaum, Daniel G.; Kovanlikaya, Arzu; Askin, Gulce; Beneck, Debra M.

    2017-01-01

    The role of magnetic resonance imaging (MRI) in pediatric appendicitis is increasing; MRI findings predictive of appendiceal perforation have not been specifically evaluated. To assess the performance of MRI in differentiating perforated from non-perforated appendicitis. A retrospective review of pediatric patients undergoing contrast-enhanced MRI and subsequent appendectomy was performed, with surgicopathological confirmation of perforation. Appendiceal diameter and the following 10 MRI findings were assessed: appendiceal restricted diffusion, wall defect, appendicolith, periappendiceal free fluid, remote free fluid, restricted diffusion within free fluid, abscess, peritoneal enhancement, ileocecal wall thickening and ileus. Two-sample t-test and chi-square tests were used to analyze continuous and discrete data, respectively. Sensitivity and specificity for individual MRI findings were calculated and optimal thresholds for measures of accuracy were selected. Seventy-seven patients (mean age: 12.2 years) with appendicitis were included, of whom 22 had perforation. The perforated group had a larger mean appendiceal diameter and mean number of MRI findings than the non-perforated group (12.3 mm vs. 8.6 mm; 5.0 vs. 2.0, respectively). Abscess, wall defect and restricted diffusion within free fluid had the greatest specificity for perforation (1.00, 1.00 and 0.96, respectively) but low sensitivity (0.36, 0.25 and 0.32, respectively). The receiver operator characteristic curve for total number of MRI findings had an area under the curve of 0.92, with an optimal threshold of 3.5. A threshold of any 4 findings had the best ability to accurately discriminate between perforated and non-perforated cases, with a sensitivity of 82% and specificity of 85%. Contrast-enhanced MRI can differentiate perforated from non-perforated appendicitis. The presence of multiple findings increases diagnostic accuracy, with a threshold of any four findings optimally discriminating between

  9. Differentiating perforated from non-perforated appendicitis on contrast-enhanced magnetic resonance imaging.

    Science.gov (United States)

    Rosenbaum, Daniel G; Askin, Gulce; Beneck, Debra M; Kovanlikaya, Arzu

    2017-10-01

    The role of magnetic resonance imaging (MRI) in pediatric appendicitis is increasing; MRI findings predictive of appendiceal perforation have not been specifically evaluated. To assess the performance of MRI in differentiating perforated from non-perforated appendicitis. A retrospective review of pediatric patients undergoing contrast-enhanced MRI and subsequent appendectomy was performed, with surgicopathological confirmation of perforation. Appendiceal diameter and the following 10 MRI findings were assessed: appendiceal restricted diffusion, wall defect, appendicolith, periappendiceal free fluid, remote free fluid, restricted diffusion within free fluid, abscess, peritoneal enhancement, ileocecal wall thickening and ileus. Two-sample t-test and chi-square tests were used to analyze continuous and discrete data, respectively. Sensitivity and specificity for individual MRI findings were calculated and optimal thresholds for measures of accuracy were selected. Seventy-seven patients (mean age: 12.2 years) with appendicitis were included, of whom 22 had perforation. The perforated group had a larger mean appendiceal diameter and mean number of MRI findings than the non-perforated group (12.3 mm vs. 8.6 mm; 5.0 vs. 2.0, respectively). Abscess, wall defect and restricted diffusion within free fluid had the greatest specificity for perforation (1.00, 1.00 and 0.96, respectively) but low sensitivity (0.36, 0.25 and 0.32, respectively). The receiver operator characteristic curve for total number of MRI findings had an area under the curve of 0.92, with an optimal threshold of 3.5. A threshold of any 4 findings had the best ability to accurately discriminate between perforated and non-perforated cases, with a sensitivity of 82% and specificity of 85%. Contrast-enhanced MRI can differentiate perforated from non-perforated appendicitis. The presence of multiple findings increases diagnostic accuracy, with a threshold of any four findings optimally discriminating between

  10. Differentiating perforated from non-perforated appendicitis on contrast-enhanced magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Rosenbaum, Daniel G.; Kovanlikaya, Arzu [New York-Presbyterian Hospital/Weill Cornell Medicine, Division of Pediatric Radiology, New York, NY (United States); Askin, Gulce [Weill Cornell Medical College, Division of Biostatistics and Epidemiology, New York, NY (United States); Beneck, Debra M. [New York-Presbyterian Hospital/Weill Cornell Medicine, Department of Pathology, New York, NY (United States)

    2017-10-15

    The role of magnetic resonance imaging (MRI) in pediatric appendicitis is increasing; MRI findings predictive of appendiceal perforation have not been specifically evaluated. To assess the performance of MRI in differentiating perforated from non-perforated appendicitis. A retrospective review of pediatric patients undergoing contrast-enhanced MRI and subsequent appendectomy was performed, with surgicopathological confirmation of perforation. Appendiceal diameter and the following 10 MRI findings were assessed: appendiceal restricted diffusion, wall defect, appendicolith, periappendiceal free fluid, remote free fluid, restricted diffusion within free fluid, abscess, peritoneal enhancement, ileocecal wall thickening and ileus. Two-sample t-test and chi-square tests were used to analyze continuous and discrete data, respectively. Sensitivity and specificity for individual MRI findings were calculated and optimal thresholds for measures of accuracy were selected. Seventy-seven patients (mean age: 12.2 years) with appendicitis were included, of whom 22 had perforation. The perforated group had a larger mean appendiceal diameter and mean number of MRI findings than the non-perforated group (12.3 mm vs. 8.6 mm; 5.0 vs. 2.0, respectively). Abscess, wall defect and restricted diffusion within free fluid had the greatest specificity for perforation (1.00, 1.00 and 0.96, respectively) but low sensitivity (0.36, 0.25 and 0.32, respectively). The receiver operator characteristic curve for total number of MRI findings had an area under the curve of 0.92, with an optimal threshold of 3.5. A threshold of any 4 findings had the best ability to accurately discriminate between perforated and non-perforated cases, with a sensitivity of 82% and specificity of 85%. Contrast-enhanced MRI can differentiate perforated from non-perforated appendicitis. The presence of multiple findings increases diagnostic accuracy, with a threshold of any four findings optimally discriminating between

  11. Time-of-flight neutron diffraction investigation of temperature factors in the Zn blende semiconductor InP

    International Nuclear Information System (INIS)

    Ferrari, C.; Bocchi, C.; Fornari, R.; Moze, O.; Wilson, C.C.

    1992-01-01

    A structural investigation of the Zn blende structure semiconductor InP has been carried out using the single crystal diffractometer SXD at the pulsed neutron facility ISIS. The ability to measure structure factors accurately at large Q values even with highly absorbing materials such as InP is demonstrated. Measurements were performed on a single crystal of InP at 293, 100 and 50 K with the crystallographic axis mounted perpendicular to the scattering plane. This enabled collection of (hhl) reflections up to a maximum with Miller indices (10, 10, 8). (orig.)

  12. Radiation damage in semiconductor detectors

    International Nuclear Information System (INIS)

    Kraner, H.W.

    1981-12-01

    A survey is presented of the important damage-producing interactions in semiconductor detectors and estimates of defect numbers are made for MeV protons, neutrons and electrons. Damage effects of fast neutrons in germanium gamma ray spectrometers are given in some detail. General effects in silicon detectors are discussed and damage constants and their relationship to leakage current is introduced

  13. Spontaneous external gallbladder perforation

    International Nuclear Information System (INIS)

    Noeldge, G.; Wimmer, B.; Kirchner, R.

    1981-01-01

    Spontaneous perforation of the gallbladder is one complication of cholelithiasis. There is a greater occurence of free perforation in the peritoneal cavity with bilary pertonitis, followed by the perforation into the stomach, small intestine and colon. A single case of the nowadays rare spontaneous perforation in and through the abdominal wall will be reported. Spontaneous gallbladder perforation appears nearly asymptomatic in its clinical course because of absent biliary peritonitis. (orig.) [de

  14. The Versatile Modiolus Perforator Flap

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Thomsen, Jorn Bo

    2016-01-01

    BACKGROUND: Perforator flaps are well established, and their usefulness as freestyle island flaps is recognized. The whereabouts of vascular perforators and classification of perforator flaps in the face are a debated subject, despite several anatomical studies showing similar consistency. In our...... experience using freestyle facial perforator flaps, we have located areas where perforators are consistently found. This study is focused on a particular perforator lateral to the angle of the mouth; the modiolus and the versatile modiolus perforator flap. METHODS: A cohort case series of 14 modiolus...... perforator flap reconstructions in 14 patients and a color Doppler ultrasonography localization of the modiolus perforator in 10 volunteers. RESULTS: All 14 flaps were successfully used to reconstruct the defects involved, and the location of the perforator was at the level of the modiolus as predicted...

  15. Effects of the inversion layer thickness and 10B distribution in it on the characteristics of ion-doped semiconductor neutron counters

    International Nuclear Information System (INIS)

    Diasamidze, Eh.M.; Solov'ev, Yu.A.; Shmakov, A.N.

    1984-01-01

    The technique for calculating the dependence of energy spectrum of the 10 B(n, α) 7 Li reaction products in the thickness of the inversion layer in a semiconductor counter fabricated using the diffusion method is proposed. The inversion layer is formed as a result of the 10 B ion implantation into n-type silicon. The cases of uniform and Gaussian distributions of 10 B impurity are considered. Corrections for neutron fluence calculation by α-peak, taking into account α-particle absorption in the inversion layer are obtained. It is concluded that the suggested calculational technique can be used for semiconductor counters fabricated by the diffusion method

  16. Characteristics of Fabricated SiC Neutron Detectors for Neutron Flux Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han Soo; Ha, Jang Ho; Park, Se Hwan; Lee, Kyu Hong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Cheol Ho [Hanyang University, Seoul (Korea, Republic of)

    2011-05-15

    An SPND (Self-powered Neutron Detector) is commonly used for neutron detection in NPP (Nuclear Power Plant) by virtue of un-reactivity for gamma-rays. But it has a drawback, which is that it cannot detect neutrons in real time due to beta emissions (about > 48 s) after reactions between neutrons and {sup 103}Rh in an SPND. And Generation IV reactors such as MSR (Molten-salt reactor), SFR (Sodium-cooled fast reactor), and GFR (Gas-cooled fast reactor) are designed to compact size and integration type. For GEN IV reactor, neutron monitor also must be compact-sized to apply such reactor easily and much more reliable. The wide band-gap semiconductors such as SiC, AlN, and diamond make them an attractive alternative in applications in harsh environments by virtue of the lower operating voltage, faster charge-collection times compared with gas-filled detectors, and compact size.1) In this study, two PIN-type SiC semiconductor neutron detectors, which are for fast neutron detection by elastic and inelastic scattering SiC atoms and for thermal neutron detection by charged particle emissions of 6LiF reaction, were designed and fabricated for NPP-related applications. Preliminary tests such as I-V and alpha response were performed and neutron responses at ENF in HANARO research reactor were also addressed. The application feasibility of the fabricated SiC neutron detector as an in-core neutron monitor was discussed

  17. Salmonella intestinal perforation: (27 perforations in one patient, 14 perforations in another Are the goal posts changing?

    Directory of Open Access Journals (Sweden)

    Adeniran J

    2005-01-01

    Full Text Available The pathology of salmonellosis after a faeco-oral transmission was first clearly described by Jenner in 1850. Over the years, the pathological manifestations in different tissues of the body have been described. The ileum is however mostly involved leading to enlarged Peyer′s patches, ulceration, and sometimes bleeding and perforation. Efforts at control have largely been improvement in public water supply, safe disposal of waste, and general public health measures. Despite these measures, intestinal perforation from salmonellosis remains the commonest cause of emergency operation in children above 3 years. The incidence continues to rise, so also the mortality, despite new antibiotics and improvement in facilities in the hospitals. Even more disturbing is that we now see more perforations per patient, and more involvement of the colon. Three recently managed patients with multiple ileal/colonic perforations were reviewed. Presenting problems, delay in referral, choice of antibiotics and postoperative complications were noted. One patient had 27 perforations and another 14 perforations. Both survived. Is salmonella changing? Are our patients changing? Is the environment changing? Are the goal posts changing? This article details our recent experience with this dreadful disease, reviews the new literature and makes suggestions for the way forwards.

  18. Simulation of space protons influence on silicon semiconductor devices using gamma-neutron irradiation

    International Nuclear Information System (INIS)

    Zhukov, Y.N.; Zinchenko, V.F.; Ulimov, V.N.

    1999-01-01

    In this study the authors focus on the problems of simulating the space proton energy spectra under laboratory gamma-neutron radiation tests of semiconductor devices (SD). A correct simulation of radiation effects implies to take into account and evaluate substantial differences in the processes of formation of primary defects in SD in space environment and under laboratory testing. These differences concern: 1) displacement defects, 2) ionization defects and 3) intensity of radiation. The study shows that: - the energy dependence of nonionizing energy loss (NIEL) is quite universal to predict the degradation of SD parameters associated to displacement defects, and - MOS devices that are sensitive to ionization defects indicated the same variation of parameters under conditions of equality of ionization density generated by protons and gamma radiations. (A.C.)

  19. Investigation on the Acoustic Absorption of Flexible Micro-Perforated Panel with Ultra-Micro Perforations

    Science.gov (United States)

    Li, Guoxin; Tang, Xiaoning; Zhang, Xiaoxiao; Qian, Y. J.; Kong, Deyi

    2017-11-01

    Flexible micro-perforated panel has unique advantages in noise reduction due to its good flexibility compared with traditional rigid micro-perforated panel. In this paper, flexible micro-perforated panel was prepared by computer numerical control (CNC) milling machine. Three kinds of plastics including polyvinylchloride (PVC), polyethylene terephthalate (PET), and polyimide (PI) were taken as the matrix materials to prepare flexible micro-perforated panel. It has been found that flexible micro-perforated panel made of PET possessing good porosity and proper density, elastic modulus and poisson ratio exhibited the best acoustic absorption properties. The effects of various structural parameters including perforation diameter, perforation ratio, thickness and air gap have also been investigated, which would be helpful to the optimization of acoustic absorption properties.

  20. Differentiation of Acute Perforated from Non-Perforated Appendicitis: Usefulness of High-Resolution Ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Gyu Chang [Dept. of Radiology, Gumi Hospital, Soonchunhyang University College of Medicine, Gumi (Korea, Republic of)

    2011-07-15

    To evaluate the usefulness of high-resolution ultrasonography (US) for the differentiation of acute perforated appendicitis from non-perforated appendicitis. The high-resolution US features in 96 patients (49 males, 47 females; mean age, 33.8 years; age range, 4-80 years) with pathologically proven acute appendicitis were evaluated. The following US findings were evaluated for differentiation of acute perforated appendicitis from non-perforated appendicitis: circumferential loss of the echogenic submucosal layer, periappendiceal fluid collection, disruption of the serosal layer, asymmetrical wall thickening, maximum overall diameter > 10.5 mm, and the presence of appendicoliths. The sensitivity and specificity of the US features in the diagnosis of acute perforated appendicitis were calculated. All of the US findings, except for appendicoliths, were significantly more common in the acute perforated appendicitis group (p < 0.001). The sensitivity of circumferential loss of the echogenic submucosal layer, periappendiceal fluid collection, disruption of the serosal layer, asymmetrical wall thickening, maximum overall diameter > 10.5 mm, and the presence of appendicoliths was 85.4, 73.2, 68.3, 70.7, 80.5, and 36.6%, respectively, while the specificity was 65.5, 89.1, 96.4, 98.2, 81.8, and 80.0%, respectively. High-resolution US was found to be useful for differentiating acute perforated appendicitis from non-perforated appendicitis.

  1. Nontraumatic terminal ileal perforation

    Directory of Open Access Journals (Sweden)

    Wani Rauf A

    2006-03-01

    Full Text Available Abstract Background There is still confusion and controversy over the diagnosis and optimal surgical treatment of non traumatic terminal ileal perforation-a cause of obscure peritonitis. Methods This study was a prospective study aimed at evaluating the clinical profile, etiology and optimal surgical management of patients with nontraumatic terminal ileal perforation. Results There were 79 cases of nontraumatic terminal ileal perforation; the causes for perforation were enteric fever(62%, nonspecific inflammation(26%, obstruction(6%, tuberculosis(4% and radiation enteritis (1%. Simple closure of the perforation (49% and end to side ileotransverse anastomosis(42% were the mainstay of the surgical management. Conclusion Terminal ileal perforation should be suspected in all cases of peritonitis especially in developing countries and surgical treatment should be optimized taking various accounts like etiology, delay in surgery and operative findings into consideration to reduce the incidence of deadly complications like fecal fistula.

  2. Determination of uranium and thorium in semiconductor memory materials by high fluence neutron activation analysis

    International Nuclear Information System (INIS)

    Dyer, F.F.; Emery, J.F.; Northcutt, K.J.; Scott, R.M.

    1981-01-01

    Uranium and thorium were measured by absolute neutron activation analysis in high-purity materials used to manufacture semiconductor memories. The main thrust of the study concerned aluminum and aluminum alloys used as sources for thin film preparation, evaporated metal films, and samples from the Czochralski silicon crystal process. Average levels of U and Th were found for the source alloys to be approx. 65 and approx. 45 ppB, respectively. Levels of U and Th in silicon samples fell in the range of a few parts per trillion. Evaporated metal films contained about 1 ppB U and Th, but there is some question about these results due to the possibility of contamination

  3. Radiation tolerance of amorphous semiconductors

    International Nuclear Information System (INIS)

    Nicolaides, R.V.; DeFeo, S.; Doremus, L.W.

    1976-01-01

    In an attempt to determine the threshold radiation damage in amorphous semiconductors, radiation tests were performed on amorphous semiconductor thin film materials and on threshold and memory devices. The influence of flash x-rays and neutron radiation upon the switching voltages, on- and off-state characteristics, dielectric response, optical transmission, absorption band edge and photoconductivity were measured prior to, during and following irradiation. These extensive tests showed the high radiation tolerance of amorphous semiconductor materials. Electrical and optical properties, other than photoconductivity, have a neutron radiation tolerance threshold above 10 17 nvt in the steady state and 10 14 nvt in short (50 μsec to 16 msec) pulses. Photoconductivity increases by 1 1 / 2 orders of magnitude at the level of 10 14 nvt (short pulses of 50 μsec). Super flash x-rays up to 5000 rads (Si), 20 nsec, do not initiate switching in off-state samples which are voltage biased up to 90 percent of the threshold voltage. Both memory and threshold amorphous devices are capable of switching on and off during nuclear radiation transients at least as high as 2 x 10 14 nvt in 50 μsec pulses

  4. Temperature driven annealing of perforations in bicellar model membranes.

    Science.gov (United States)

    Nieh, Mu-Ping; Raghunathan, V A; Pabst, Georg; Harroun, Thad; Nagashima, Kazuomi; Morales, Hannah; Katsaras, John; Macdonald, Peter

    2011-04-19

    Bicellar model membranes composed of 1,2-dimyristoylphosphatidylcholine (DMPC) and 1,2-dihexanoylphosphatidylcholine (DHPC), with a DMPC/DHPC molar ratio of 5, and doped with the negatively charged lipid 1,2-dimyristoylphosphatidylglycerol (DMPG), at DMPG/DMPC molar ratios of 0.02 or 0.1, were examined using small angle neutron scattering (SANS), (31)P NMR, and (1)H pulsed field gradient (PFG) diffusion NMR with the goal of understanding temperature effects on the DHPC-dependent perforations in these self-assembled membrane mimetics. Over the temperature range studied via SANS (300-330 K), these bicellar lipid mixtures exhibited a well-ordered lamellar phase. The interlamellar spacing d increased with increasing temperature, in direct contrast to the decrease in d observed upon increasing temperature with otherwise identical lipid mixtures lacking DHPC. (31)P NMR measurements on magnetically aligned bicellar mixtures of identical composition indicated a progressive migration of DHPC from regions of high curvature into planar regions with increasing temperature, and in accord with the "mixed bicelle model" (Triba, M. N.; Warschawski, D. E.; Devaux, P. E. Biophys. J.2005, 88, 1887-1901). Parallel PFG diffusion NMR measurements of transbilayer water diffusion, where the observed diffusion is dependent on the fractional surface area of lamellar perforations, showed that transbilayer water diffusion decreased with increasing temperature. A model is proposed consistent with the SANS, (31)P NMR, and PFG diffusion NMR data, wherein increasing temperature drives the progressive migration of DHPC out of high-curvature regions, consequently decreasing the fractional volume of lamellar perforations, so that water occupying these perforations redistributes into the interlamellar volume, thereby increasing the interlamellar spacing. © 2011 American Chemical Society

  5. Reactive perforating collagenosis

    Directory of Open Access Journals (Sweden)

    Yadav Mukesh

    2009-01-01

    Full Text Available Reactive perforating collagenosis is a rare cutaneous disorder of unknown etiology. We hereby describe a case of acquired reactive perforating collagenosis in a patient of diabetes and chronic renal failure.

  6. Combining rhinoplasty with septal perforation repair.

    Science.gov (United States)

    Foda, Hossam M T; Magdy, Emad A

    2006-11-01

    A combined septal perforation repair and rhinoplasty was performed in 80 patients presenting with septal perforations (size 1 to 5 cm) and external nasal deformities. The external rhinoplasty approach was used for all cases and the perforation was repaired using bilateral intranasal mucosal advancement flaps with a connective tissue interposition graft in between. Complete closure of the perforation was achieved in 90% of perforations of size up to 3.5 cm and in only 70% of perforations that were larger than 3.5 cm. Cosmetically, 95% were very satisfied with their aesthetic result. The external rhinoplasty approach proved to be very helpful in the process of septal perforation repair especially in large and posteriorly located perforations and in cases where the caudal septal cartilage was previously resected. Our results show that septal perforation repair can be safely combined with rhinoplasty and that some of the routine rhinoplasty maneuvers, such as medial osteotomies and dorsal lowering, could even facilitate the process of septal perforation repair.

  7. Review of current neutron detection systems for emergency response

    Science.gov (United States)

    Mukhopadhyay, Sanjoy; Maurer, Richard; Guss, Paul; Kruschwitz, Craig

    2014-09-01

    Neutron detectors are used in a myriad of applications—from safeguarding special nuclear materials (SNM) to determining lattice spacing in soft materials. The transformational changes taking place in neutron detection and imaging techniques in the last few years are largely being driven by the global shortage of helium-3 (3He). This article reviews the status of neutron sensors used specifically for SNM detection in radiological emergency response. These neutron detectors must be highly efficient, be rugged, have fast electronics to measure neutron multiplicity, and be capable of measuring direction of the neutron sources and possibly image them with high spatial resolution. Neutron detection is an indirect physical process: neutrons react with nuclei in materials to initiate the release of one or more charged particles that produce electric signals that can be processed by the detection system. Therefore, neutron detection requires conversion materials as active elements of the detection system; these materials may include boron-10 (10B), lithium-6 (6Li), and gadollinium-157 (157Gd), to name a few, but the number of materials available for neutron detection is limited. However, in recent years, pulse-shape-discriminating plastic scintillators, scintillators made of helium-4 (4He) under high pressure, pillar and trench semiconductor diodes, and exotic semiconductor neutron detectors made from uranium oxide and other materials have widely expanded the parameter space in neutron detection methodology. In this article we will pay special attention to semiconductor-based neutron sensors. Modern microfabricated nanotubes covered inside with neutron converter materials and with very high aspect ratios for better charge transport will be discussed.

  8. Soft error modeling and analysis of the Neutron Intercepting Silicon Chip (NISC)

    International Nuclear Information System (INIS)

    Celik, Cihangir; Unlue, Kenan; Narayanan, Vijaykrishnan; Irwin, Mary J.

    2011-01-01

    Soft errors are transient errors caused due to excess charge carriers induced primarily by external radiations in the semiconductor devices. Soft error phenomena could be used to detect thermal neutrons with a neutron monitoring/detection system by enhancing soft error occurrences in the memory devices. This way, one can convert all semiconductor memory devices into neutron detection systems. Such a device is being developed at The Pennsylvania State University and named Neutron Intercepting Silicon Chip (NISC). The NISC is envisioning a miniature, power efficient, and active/passive operation neutron sensor/detector system. NISC aims to achieve this goal by introducing 10 B-enriched Borophosphosilicate Glass (BPSG) insulation layers in the semiconductor memories. In order to model and analyze the NISC, an analysis tool using Geant4 as the transport and tracking engine is developed for the simulation of the charged particle interactions in the semiconductor memory model, named NISC Soft Error Analysis Tool (NISCSAT). A simple model with 10 B-enriched layer on top of the lumped silicon region is developed in order to represent the semiconductor memory node. Soft error probability calculations were performed via the NISCSAT with both single node and array configurations to investigate device scaling by using different node dimensions in the model. Mono-energetic, mono-directional thermal and fast neutrons are used as the neutron sources. Soft error contribution due to the BPSG layer is also investigated with different 10 B contents and the results are presented in this paper.

  9. Spectrum of Perforation Peritonitis

    Science.gov (United States)

    Chakma, Sujit M.; Singh, Rahul L.; Parmekar, Mahadev V.; Singh, K.H. Gojen; Kapa, Buru; Sharatchandra, K.H.; Longkumer, Amenla T.; Rudrappa, Santhosh

    2013-01-01

    Introduction: Perforation peritonitis mostly results from the perforation of a diseased viscus. Other causes of perforation include abdominal trauma, ingestion of sharp foreign body and iatrogenic perforation. The diagnosis is mainly based on clinical grounds. Plain abdominal X-rays (erect) may reveal dilated and oedematous intestines with pneumoperitoneum. Ultrasound and CT scan may diagnose up to 72% and 82% of perforation respectively. The present study was carried out to study various etiological factors, modes of clinical presentation, morbidity and mortality patterns of perforation peritonitis presented in the RIMS hospital, Imphal, India. Material and Methods: The study was conducted from September 2010 to August 2012 on 490 cases of perforation peritonitis admitted and treated in the Department of Surgery. Initial diagnosis was made on the basis of detailed history, clinical examination and presence of pneumoperitoneum on erect abdominal X-ray. Results: A total of 490 patients of perforation peritonitis were included in the study, with mean age of 48.28 years. 54.29% patients were below 50 years and 45.71% patients were above 50 years. There were 54.29% male patients and 45.71% female patients. Only 30% patients presented within 24 hours of onset of symptoms, 31.43% patients presented between 24 to 72 hours and 38.57% patients presented 72 hours after the onset of symptoms. Mean duration of presentation was 54.7 hours. Overall 469 patients were treated surgically and 21 patients were managed conservatively. Overall morbidity and mortality recorded in this study were 52.24% and 10% respectively. PMID:24392388

  10. Perforations during contrast enema

    International Nuclear Information System (INIS)

    Vogel, H.; Steinkamp, U.; Grabbe, E.; Allgemeines Krankenhaus Ochsenzoll, Hamburg

    1983-01-01

    During contrast enema, perforation into the retroperitoneal space can be differentiated from perforation into the peritoneum and perforation into the intestinal wall associated with formation of barium granulomas or submucosal spreading of the contrast medium. Other special forms are perforation with contrast medium embolism of diverticula; of the processus vermiformis; penetration of contrast medium into fistulous systems and from the operated areas. Risk factors are: balloon catheter, intestinal tubes with a hard tip, preternatural anus, excessive enema pressure, contrast medium additions, preceding manipulations, intestinal diseases, advanced age and delegation of manipulations to assistants and unskilled staff. Children are particularly at risk. (orig.) [de

  11. Device fabrication, characterization, and thermal neutron detection response of LiZnP and LiZnAs semiconductor devices

    Science.gov (United States)

    Montag, Benjamin W.; Ugorowski, Philip B.; Nelson, Kyle A.; Edwards, Nathaniel S.; McGregor, Douglas S.

    2016-11-01

    Nowotny-Juza compounds continue to be explored as candidates for solid-state neutron detectors. Such a device would have greater efficiency, in a compact form, than present day gas-filled 3He and 10BF3 detectors. The 6Li(n,t)4He reaction yields a total Q-value of 4.78 MeV, larger than 10B, an energy easily identified above background radiations. Hence, devices fabricated from semiconductor compounds having either natural Li (nominally 7.5% 6Li) or enriched 6Li (usually 95% 6Li) as constituent atoms may provide a material for compact high efficiency neutron detectors. Starting material was synthesized by preparing equimolar portions of Li, Zn, and As sealed under vacuum (10-6 Torr) in quartz ampoules lined with boron nitride and subsequently reacted in a compounding furnace [1]. The raw synthesized material indicated the presence high impurity levels (material and electrical property characterizations). A static vacuum sublimation in quartz was performed to help purify the synthesized material [2,3]. Bulk crystalline samples were grown from the purified material [4,5]. Samples were cut using a diamond wire saw, and processed into devices. Bulk resistivity was determined from I-V curve measurements, ranging from 106-1011 Ω cm. Devices were characterized for sensitivity to 5.48 MeV alpha particles, 337 nm laser light, and neutron sensitivity in a thermal neutron diffracted beam at the Kansas State University TRIGA Mark II nuclear reactor. Thermal neutron reaction product charge induction was measured with a LiZnP device, and the reaction product spectral response was observed.

  12. The freestyle pedicle perforator flap

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Jackson, Ian T; Westvik, Tormod S

    2015-01-01

    BACKGROUND: Perforating vessels are a consistent anatomical finding and well described in the current literature. Any skin flap can be raised on a subcutaneous pedicle as long as it contains at least one supplying perforator. Perforator flaps have been interlinked with microsurgery and generally...... not widely performed by the general plastic surgeons. The aim of this paper is to present the simplicity of pedicled perforator flap reconstruction of moderate-sized defects of the extremities and torso. METHODS: We retrospectively reviewed the charts of 34 patients reconstructed using 34 freestyle pedicled...... perforator flaps for moderate-sized defects of the truncus and extremities. We registered indications, flap size and localization, success rate, and complications. Most importantly, we describe a simple approach to the design of freestyle pedicled perforator flaps and elaborate on technical aspects...

  13. Semiconductor radiation detector

    Science.gov (United States)

    Bell, Zane W.; Burger, Arnold

    2010-03-30

    A semiconductor detector for ionizing electromagnetic radiation, neutrons, and energetic charged particles. The detecting element is comprised of a compound having the composition I-III-VI.sub.2 or II-IV-V.sub.2 where the "I" component is from column 1A or 1B of the periodic table, the "II" component is from column 2B, the "III" component is from column 3A, the "IV" component is from column 4A, the "V" component is from column 5A, and the "VI" component is from column 6A. The detecting element detects ionizing radiation by generating a signal proportional to the energy deposited in the element, and detects neutrons by virtue of the ionizing radiation emitted by one or more of the constituent materials subsequent to capture. The detector may contain more than one neutron-sensitive component.

  14. Blasting detonators incorporating semiconductor bridge technology

    Energy Technology Data Exchange (ETDEWEB)

    Bickes, R.W. Jr.

    1994-05-01

    The enormity of the coal mine and extraction industries in Russia and the obvious need in both Russia and the US for cost savings and enhanced safety in those industries suggests that joint studies and research would be of mutual benefit. The author suggests that mine sites and well platforms in Russia offer an excellent opportunity for the testing of Sandia`s precise time-delay semiconductor bridge detonators, with the potential for commercialization of the detonators for Russian and other world markets by both US and Russian companies. Sandia`s semiconductor bridge is generating interest among the blasting, mining and perforation industries. The semiconductor bridge is approximately 100 microns long, 380 microns wide and 2 microns thick. The input energy required for semiconductor bridge ignition is one-tenth the energy required for conventional bridgewire devices. Because semiconductor bridge processing is compatible with other microcircuit processing, timing and logic circuits can be incorporated onto the chip with the bridge. These circuits can provide for the precise timing demanded for cast effecting blasting. Indeed tests by Martin Marietta and computer studies by Sandia have shown that such precise timing provides for more uniform rock fragmentation, less fly rock, reduce4d ground shock, fewer ground contaminants and less dust. Cost studies have revealed that the use of precisely timed semiconductor bridges can provide a savings of $200,000 per site per year. In addition to Russia`s vast mineral resources, the Russian Mining Institute outside Moscow has had significant programs in rock fragmentation for many years. He anticipated that collaborative studies by the Institute and Sandia`s modellers would be a valuable resource for field studies.

  15. Terrestrial neutron-induced soft errors in advanced memory devices

    CERN Document Server

    Nakamura, Takashi; Ibe, Eishi; Yahagi, Yasuo; Kameyama, Hideaki

    2008-01-01

    Terrestrial neutron-induced soft errors in semiconductor memory devices are currently a major concern in reliability issues. Understanding the mechanism and quantifying soft-error rates are primarily crucial for the design and quality assurance of semiconductor memory devices. This book covers the relevant up-to-date topics in terrestrial neutron-induced soft errors, and aims to provide succinct knowledge on neutron-induced soft errors to the readers by presenting several valuable and unique features. Sample Chapter(s). Chapter 1: Introduction (238 KB). Table A.30 mentioned in Appendix A.6 on

  16. The electronic band structures of gadolinium chalcogenides: a first-principles prediction for neutron detecting.

    Science.gov (United States)

    Li, Kexue; Liu, Lei; Yu, Peter Y; Chen, Xiaobo; Shen, D Z

    2016-05-11

    By converting the energy of nuclear radiation to excited electrons and holes, semiconductor detectors have provided a highly efficient way for detecting them, such as photons or charged particles. However, for detecting the radiated neutrons, those conventional semiconductors hardly behave well, as few of them possess enough capability for capturing these neutral particles. While the element Gd has the highest nuclear cross section, here for searching proper neutron-detecting semiconductors, we investigate theoretically the Gd chalcogenides whose electronic band structures have never been characterized clearly. Among them, we identify that γ-phase Gd2Se3 should be the best candidate for neutron detecting since it possesses not only the right bandgap of 1.76 eV for devices working under room temperature but also the desired indirect gap nature for charge carriers surviving longer. We propose further that semiconductor neutron detectors with single-neutron sensitivity can be realized with such a Gd-chalcogenide on the condition that their crystals can be grown with good quality.

  17. Determination of thorium and uranium at the nanogram per gram level in semiconductor potting plastics by neutron activation analysis

    International Nuclear Information System (INIS)

    Dyer, F.F.; Emery, J.F.; Bate, L.C.

    1985-01-01

    A method was developed to determine thorium and uranium in semiconductor potting plastics. The method is based on neutron activation and subsequent radiochemical separation to isolate and permit measurement of the induced 233 Pa and 239 Np. These plastics typically contain macro amounts of silicon, bromine and antimony and nanogram per gram amounts of thorium and uranium. The radiochemical method provides the necessary sensitivity and makes it possible to easily attain adequate decontamination of the tiny amounts of 233 Pa and 239 Np from the high levels of radioactive bromine and antimony. 8 refs

  18. CT in acute perforated sigmoid diverticulitis

    International Nuclear Information System (INIS)

    Lohrmann, Christian; Ghanem, Nadir; Pache, Gregor; Makowiec, Frank; Kotter, Elmar; Langer, Mathias

    2005-01-01

    Background: To assess the value of computed tomography (CT) in patients with acute perforated sigmoid diverticulitis in correlation with the Hinchey classification of perforated diverticular disease. Methods: Thirty patients with acute perforated sigmoid diverticulitis underwent computed tomography prior to surgery. Computed tomography scans were compared with the surgical and histopathological reports, utilizing the Hinchey classification. Results: In 28 of the 30 (93%) patients examined, the Hinchey stage was correctly determined by means of computed tomography. One patient with Hinchey stage IV was falsely classified as Hinchey stage III, and one patient with Hinchey stage III as Hinchey stage II. Computed tomography revealed 12 out of 14 (86%) patients with perforation sites and 3 out of 3 (100%) patients with contained perforation. In one of 17 (6%) patients with surgically or histopathologically proven perforation or contained perforation, a bowel wall discontinuity was revealed by computed tomography. In 6 of the 17 (35%) patients with surgical or histopathological perforation or contained perforation, extraluminal contrast material was detected by computed tomography. Conclusions: Computed tomography is a valuable imaging tool for determining the degree of acute perforated sigmoid diverticulitis, by means of which patients can be stratified according to the severity of the disease; furthermore, this tool is of assistance in surgical planning

  19. Experimental characterization of semiconductor-based thermal neutron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bedogni, R., E-mail: roberto.bedogni@lnf.infn.it [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); Bortot, D.; Pola, A.; Introini, M.V.; Lorenzoli, M. [Politecnico di Milano, Dipartimento di Energia, via La Masa 34, 20156 Milano (Italy); INFN—Milano, Via Celoria 16, 20133 Milano (Italy); Gómez-Ros, J.M. [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); CIEMAT, Av. Complutense 40, 28040 Madrid (Spain); Sacco, D. [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); INAIL—DIT, Via di Fontana Candida 1, 00040 Monteporzio Catone (Italy); Esposito, A.; Gentile, A.; Buonomo, B. [IFNF—LNF, via E. Fermi n. 40, 00044 Frascati, Roma (Italy); Palomba, M.; Grossi, A. [ENEA Triga RC-1C.R. Casaccia, via Anguillarese 301, 00060 S. Maria di Galeria, Roma (Italy)

    2015-04-21

    In the framework of NESCOFI@BTF and NEURAPID projects, active thermal neutron detectors were manufactured by depositing appropriate thickness of {sup 6}LiF on commercially available windowless p–i–n diodes. Detectors with different radiator thickness, ranging from 5 to 62 μm, were manufactured by evaporation-based deposition technique and exposed to known values of thermal neutron fluence in two thermal neutron facilities exhibiting different irradiation geometries. The following properties of the detector response were investigated and presented in this work: thickness dependence, impact of parasitic effects (photons and epithermal neutrons), linearity, isotropy, and radiation damage following exposure to large fluence (in the order of 10{sup 12} cm{sup −2})

  20. High-Resolution Ultrasonography (US) of Appendiceal Specimens: Differentiation of Acute Non-perforated Appendicitis from Perforated Appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Gyo Chang; Kim, Suk; Im, Han Hyeok; Lee, Sang Jin; Yang, Seung Boo; Lee, Seung Woo; Kim, Il Young [Soonchunhyang University Gumi Hospital, Gumi (Korea, Republic of); Lee, Hae Kyung [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Kwon, Kui Hyang; Shin, Hyung Chul [Soonchunhyang University, College of Medicine, Seoul (Korea, Republic of)

    2007-09-15

    To analyze surgical specimens from patients with acute non-perforated and perforated appendicitis using high-resolution ultrasonography (US), and to correlate the US features with the pathologic findings. One hundred and six surgical appendix specimens obtained from patients with suspected acute appendicitis were evaluated. The following US features were evaluated for differentiating acute non-perforated appendicitis from perforated appendicitis: circumferential loss of the echogenic submucosal layer, disruption of the serosal layer, asymmetrical wall thickening, the sum of opposing walls {>=} 9 mm and the presence of appendicoliths. The sensitivity and specificity of the US findings for diagnosing perforated appendicitis were determined. All US features were detected significantly more often in the perforated appendicitis group of specimens. The disruption of the serosal layer was the most significant independent predictor of perforation (p < .001). The sensitivity for circumferential loss of the echogenic submucosal layer, disruption of the serosal layer, asymmetrical wall thickening, wall thickness {>=} 9 mm, and the presence of appendicoliths individually was 84.6%, 69.2%, 61.5%, 73.1% and 46.2%, respectively. The specificity for all of these findings was 86.3%, 98.7%, 95.0%, 85.0% and 85.0%, respectively. High-resolution US of appendiceal specimens was very useful for differentiating acute non-perforated from perforated appendicitis

  1. Management of biliary perforation in children

    Directory of Open Access Journals (Sweden)

    Mirza Bilal

    2010-01-01

    Full Text Available Background: To study the aetiology, management and outcome of biliary perforations in paediatric age group. Patients and Methods: In a retrospective study, the records of patients presented with biliary peritonitis due to biliary perforations, managed from March 2006 to July 2009, are reviewed. Results: Eight male patients with biliary peritonitis due to biliary perforation were managed. These patients were divided in two groups, A and B. Group A, (n = 3 patients, had common bile duct (CBD perforation, and Group B (n=5 patients had gallbladder perforation. The presenting features were abdominal pain, fever, abdominal distension, vomiting, constipation, jaundice and signs of peritonism. The management of CBD perforations in Group A was by draining the site of perforation and biliary diversion (tube cholecystostomy. In Group B, the gallbladder perforations were managed by tube cholecystostomy in four patients and cholecystectomy in one patient, however, one patient had to be re-explored and cholecystectomy performed due to complete necrosis of gall bladder. There was no mortality in our series. All patients were asymptomatic on regular follow-up. Conclusion: Early optimal management of biliary perforations remarkably improved the very high mortality and morbidity that characterised this condition in the past.

  2. Early Management Experience of Perforation after ERCP

    Directory of Open Access Journals (Sweden)

    Guohua Li

    2012-01-01

    Full Text Available Background and Aim. Perforation after endoscopic retrograde cholangiopancreatography (ERCP is a rare complication, but it is associated with significant mortality. This study evaluated the early management experience of these perforations. Patients and Methods. Between November 2003 and December 2011, a total of 8504 ERCPs were performed at our regional endoscopy center. Sixteen perforations (0.45% were identified and retrospectively reviewed. Results. Nine of these 16 patients with perforations were periampullary, 3 duodenal, 1 gastric fundus, and 3 patients had a perforation of an afferent limb of a Billroth II anastomosis. All patients with perforations were recognized during ERCP by X-ray and managed immediately. One patient with duodenal perforation and three patients with afferent limb perforation received surgery, others received medical conservative treatment which included suturing lesion, endoscopic nasobiliary drainage (ENBD, endoscopic retrograde pancreatic duct drainage (ERPD, gastrointestinal decompression, fasting, broad-spectrum antibiotics, and so on. All patients with perforation recovered successfully. Conclusions. We found that: (1 the diagnosis of perforation during ERCP may be easy, but you must pay attention to it. (2 Most retroperitoneal perforations can recover with only medical conservative treatment in early phase. (3 Most peritoneal perforations need surgery unless you can close the lesion up under endoscopy in early phase.

  3. The Perforation-Operation time Interval; An Important Mortality Indicator in Peptic Ulcer Perforation.

    Science.gov (United States)

    Surapaneni, Sushama; S, Rajkumar; Reddy A, Vijaya Bhaskar

    2013-05-01

    To find out the significance of the Perforation-Operation Interval (POI) with respect to an early prognosis, in patients with peritonitis which is caused by peptic ulcer perforation. Case series. Place and Duration of the Study: Department of General Surgery, Konaseema Institute of Medical Sciences and RF Amalapuram, Andhra Pradesh, India from 2008-2011. This study included 150 patients with generalized peritonitis, who were diagnosed to have Perforated Peptic Ulcers (PPUs). The diagnosis of the PPUs was established on the basis of the history , the clinical examination and the radiological findings. The perforation-operation interval was calculated from the time of onset of the symptoms like severe abdominal pain or vomiting till the time the patient was operated. Out of the 150 patients 134 were males and 16 were females, with a male : female ratio of 9:1. Their ages ranged between 25-70 years. Out of the 150 patients, 65 patients (43.3%) presented within 24 hours of the onset of severe abdominal pain (Group A), 27 patients (18%) presented between 24-48 hours of the onset of severe abdominal pain (Group B) and 58 patients (38.6%) presented after 48 hours. There was no mortality in Group A and the morbidity was more in Group B and Group C. There were 15 deaths in Group C. The problem of peptic ulcer perforation with its complication, can be decreased by decreasing the perforation -operation time interval, which as per our study, appeared to be the single most important mortality and morbidity indicator in peptic ulcer perforation.

  4. Pulsed Neutron log application in accurate fluid contact determination and remedial action planning

    International Nuclear Information System (INIS)

    Kalu, I.; Mukerji, P.

    2002-01-01

    A common application of pulsed neutron logging in the Niger Delta is saturation monitoring when run in carbon-oxygen (CO) mode. Recently, one such log was run across a reservoir to confirm the position of the oil-water contact on a well that was producing at very high water cut on the short string of a dual string producer. Material balance calculations had predicted an oil-water contact about 5ft from the deepest perforations and so a water shut-off operation had been planned. The interpreted log however showed that the OWC was about 30ft from the perforation and it also showed fluid movement in the borehole in front of the perforations. A production log was subsequently run which identified a tubing leak and confirmed the crossflow of water from the long string into the short string detected on the pulsed neutron log. The proposed water shut-off treatment was aborted based on the interpretation and resulted in substantial savings

  5. Simulation of a silicon neutron detector coated with TiB2 absorber

    International Nuclear Information System (INIS)

    Krapohl, D; Nilsson, H-E; Petersson, S; Slavicek, T; Thungström, G; Pospisil, S

    2012-01-01

    Neutron radiation cannot be directly detected in semiconductor detectors and therefore needs converter layers. Planar clean-room processing can be used in the manufacturing process of semiconductor detectors with metal layers to produce a cost-effective device. We used the Geant4 Monte-Carlo toolkit to simulate the performance of a semiconductor neutron detector. A silicon photo-diode was coated with vapour deposited titanium, aluminium thin films and a titaniumdiboride (TiB 2 ) neutron absorber layer. The neutron capture reaction 10B(n, alpha)7Li is taken advantage of to create charged particles that can be counted. Boron-10 has a natural abundance of about SI 19.8%. The emitted alpha particles are absorbed in the underlying silicon detector. We varied the thickness of the converter layer and ran the simulation with a thermal neutron source in order to find the best efficiency of the TiB 2 converter layer and optimize the clean room process.

  6. Vibrational spectra for hydrogenated amorphous semiconductors

    International Nuclear Information System (INIS)

    Kamitakahara, W.A.; Bouchard, A.M.; Biswas, R.; Gompf, F.; Suck, J.B.

    1990-01-01

    Hydrogen vibration spectra have been measured by neutron scattering for several amorphous semiconductor materials, including a-Ge:H and a-SiC:H samples containing about 10 at. % H. The data for a-Ge:H are compared in detail with the results of realistic computer simulations

  7. Scoring system for differentiating perforated and non-perforated pediatric appendicitis.

    Science.gov (United States)

    Blumfield, Einat; Yang, Daniel; Grossman, Joshua

    2017-10-01

    Appendicitis is the most common indication for emergency pediatric surgery and its most significant complication is perforation. Perforated appendicitis (PA) may be managed conservatively, whereas non-perforated appendicitis (NP) is managed surgically. Recent studies have shown that ultrasound (US) is effective for differentiating between PA and NP, and does not expose pediatric patients to ionizing radiation. The purpose of this study is to enhance the accuracy of differentiation with a novel scoring system based on clinical, laboratory, and US findings. This retrospective study included 243 patients aged 2-17 years who presented between 2006 and 2013 with surgically proven appendicitis, of whom 60 had perforation. Clinical and laboratory data were collected and US images evaluated by a pediatric radiologist. To create the scoring system, point values were assigned to each parameter. A randomly selected training sample of 137 subjects was used to create a scoring prediction model. The model was tested on the remaining 106 patients. Scores of ≥6, ≥11, and ≥15 yielded specificities of 64, 91, and 99%, and sensitivities of 96, 61, and 29%, respectively (p < 0.001). We have designed a scoring system incorporating clinical, laboratory, and sonographic findings which can differentiate PA from NP with high specificity.

  8. Pulsed neutron generator for mass flow measurement using the pulsed neutron activation technique

    International Nuclear Information System (INIS)

    Rochau, G.E.; Hornsby, D.R.; Mareda, J.F.; Riggan, W.C.

    1980-01-01

    A high-output, transportable neutron generator has been developed to measure mass flow velocities in reactor safety tests using the Pulsed Neutron Activation (PNA) Technique. The PNA generator produces >10 10 14 MeV D-T neutrons in a 1.2 millisecond pulse. The Millisecond Pulse (MSP) Neutron Tube, developed for this application, has an expected operational life of 1000 pulses, and it limits the generator pulse repetition rate to 12 pulses/minute. A semiconductor neutron detector is included in the generator package to monitor the neutron output. The control unit, which can be operated manually or remotely, also contains a digital display with a BCD output for the neutron monitor information. The digital logic of the unit controls the safety interlocks and rejects transient signals which could accidently fire the generator

  9. Dimensional changes of alginate impression by using perforated and non-perforated ring trays

    Directory of Open Access Journals (Sweden)

    Sumadhi Sastrodihardjo

    2010-03-01

    Full Text Available Dimensional changes are a common occurrence in impressions, either during or after impression taking. It produces a difference in the dimensions of the object and the model, which leads to the restoration being ill-fitted. Several causal factors have been proposed such as friction between the impression material and the teeth, the bulk of the impression material, the type of impression materials used, the impression technique, the pouring time and many others. The exact causal factor is still unknown and the dimensional change mechanism is still poorly understood. The objective of this research was to investigate the role of the perforation on the ring trays in producing dimensional changes in the impression by using perforated and non-perforated ring trays. Alginate impressions were made on the frustum of cone metal master die with a 7.08 mm base diameter, 7.03 mm top diameter and 9.23 mm height using perforated and non-perforated ring trays with 9.40 mm in diameter and 14.17 mm in height. The dimensional change was determined by comparing the dimension of the dental stone die and its metal master die. The results showed that the percentage of dimensional changes that occurred by using perforated ring tray were (+ 0.56±0.40 on the top area, (- 3.54±2.92 on base area and (+ 1.54±0.83 in height, respectively. As compared to using non-perforated ring trays, the percentage of dimensional changes that occurred were (- 0.49±0.49 on top area, (- 8.76±3.95 on base area and (+ 1.19±0.71 in height, respectively. There was a significant difference in the direction of the dimensional changes on both the top areas, but not in the base areas and height.

  10. Delta neutrophil index: A reliable marker to differentiate perforated appendicitis from non-perforated appendicitis in the elderly.

    Science.gov (United States)

    Shin, Dong Hyuk; Cho, Young Suk; Kim, Yoon Sung; Ahn, Hee Cheol; Oh, Young Taeck; Park, Sang O; Won, Moo-Ho; Cho, Jun Hwi; Kim, Young Myeong; Seo, Jeong Yeol; Lee, Young Hwan

    2018-01-01

    Delta neutrophil index (DNI) is a new inflammatory marker and the present study aimed to evaluate the predictive value of the DNI for the presence of a perforation in elderly with acute appendicitis. This retrospective observational study was conducted on 108 consecutive elderly patients (≥65 years old) with acute appendicitis treated over a 24-month period. Sixty-nine of the 108 patients (median, IQR: 72, 67-77 years) were allocated to the perforated appendicitis group (63.9%) and 39 to the non-perforated appendicitis group (36.1%). WBC, neutrophil-to-lymphocyte ratio, platelet-to-lymphocyte ratio and DNI were significantly higher in the perforated group. In multiple logistic regression analyses, initial DNI was the only independent marker that can significantly predict the presence of perforation in multiple regression [odds ratio 9.38, 95% confidence interval (2.51-35.00), P=.001]. Receiver operator characteristic curve analysis showed that DNI is a good predictor for the presence of appendiceal perforation at an optimal cut-off for DNI being 1.4% (sensitivity 67.7%, specificity 90.0%, AUC 0.807). Clinicians can reliably differentiate acute perforated appendicitis from non-perforated appendicitis by DNI level of 1.4 or more in elderly patients. © 2017 Wiley Periodicals, Inc.

  11. CT findings of exophageal perforation

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Jeong Nam; Choi, Yo Won; Jeon, Seok Chol; Park, Choong Ki; Hahm, Chang Kok [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2002-09-01

    To determine which CT findings are useful for the early disgnosis of esophageal perforation, and on the basis of these findings, to assess the accuracy of prediction of the perforation site. A review of medical records indicated that between January 1995 and December 2001, 36 patients with esophageal perforation were admitted to our hospital. Thirteen of these [M:F=8:5, age; 28-69 (mean, 52.4) years], who had undergone CT chest scanning, were included in this study. The causes of esophageal perforation were trauma (n=5), infectious diseases (n=4), Boerhaave syndrome (n=1), lung cancer (n=1), esophageal cancer (n=1), and idiopathic. Two chest radiologists unaware of the clinical findings reviewed the CT scans and predicted whether the upper or lower esophagus was perforated. The most common CT finding was extraluminal air at the posterior mediastinum (n=11), while other findings included pulmonary consolidation (n=10), pleural effusion (n=7), discontinuity of the esophageal wall (n=6) and subcutaneous emphysema (n=4), fluid collection around the esophagus (n-4), esophageal wall thickening (n=4), pneumothorax (n=2), and lung abscess (n=2). The perforation site was accurately predicted in 76.9% of cases (10/13). The CT findings which help the diagnosis of esophageal perforation, and prediction of the sites at which it occurs, are extraluminal air of fluid collection, focal defect of the esophageal wall, and esophageal wall thickening.

  12. CT findings of exophageal perforation

    International Nuclear Information System (INIS)

    Heo, Jeong Nam; Choi, Yo Won; Jeon, Seok Chol; Park, Choong Ki; Hahm, Chang Kok

    2002-01-01

    To determine which CT findings are useful for the early disgnosis of esophageal perforation, and on the basis of these findings, to assess the accuracy of prediction of the perforation site. A review of medical records indicated that between January 1995 and December 2001, 36 patients with esophageal perforation were admitted to our hospital. Thirteen of these [M:F=8:5, age; 28-69 (mean, 52.4) years], who had undergone CT chest scanning, were included in this study. The causes of esophageal perforation were trauma (n=5), infectious diseases (n=4), Boerhaave syndrome (n=1), lung cancer (n=1), esophageal cancer (n=1), and idiopathic. Two chest radiologists unaware of the clinical findings reviewed the CT scans and predicted whether the upper or lower esophagus was perforated. The most common CT finding was extraluminal air at the posterior mediastinum (n=11), while other findings included pulmonary consolidation (n=10), pleural effusion (n=7), discontinuity of the esophageal wall (n=6) and subcutaneous emphysema (n=4), fluid collection around the esophagus (n-4), esophageal wall thickening (n=4), pneumothorax (n=2), and lung abscess (n=2). The perforation site was accurately predicted in 76.9% of cases (10/13). The CT findings which help the diagnosis of esophageal perforation, and prediction of the sites at which it occurs, are extraluminal air of fluid collection, focal defect of the esophageal wall, and esophageal wall thickening

  13. Current management of peptic ulcer perforations

    International Nuclear Information System (INIS)

    Menakuru, S.R.

    2004-01-01

    Perforation is a life-threatening complication of peptic ulcer disease. Smoking and use of non-steroidal anti-inflammatory drugs are important risk factors for perforation. Diagnosis is made clinically and confirmed by the presence of pneumoperitoneum on radiographs. Nonoperative management is successful in patients identified to have a spontaneously sealed perforation proven by water-soluble contrast gastroduodenogram. Operative management consists of the time-honoured practice of mental patch closure, but now this can be done by laparoscopic methods. The practice of addition of acid-reducing procedures is currently being debated though it continues to be recommended in good-risk patients. Laparoscopic approaches to closure of duodenal perforation are now being applied widely and may become the gold standard in the future especially in patients with < 10 mm perforation size presenting within the first 24 hours of onset of pain. The role of Helicobacter pylori in duodenal ulcer perforation is controversial and more studies are needed to answer this question though recent indirect evidence suggests that eradicating H pylori may reduce the necessity for adding acid reducing procedures and the associated morbidity. Perforation is a life-threatening complication of peptic ulcer disease. The management of peptic ulcer disease has evolved over the decades, due to advances in operative techniques, bacteriology and pharmacology. While the recognition of the role of Helicobacter pylori (H. pylori) in peptic ulceration has resulted in a paradigm shift in the management of uncomplicated peptic ulcers, debate continues about the appropriate management of perforated duodenal bulb and prepyloric ulcers. A new dimension has been added to this controversy by the advent of laparoscopic techniques for closing the perforation. A Medline search of all articles dealing with the management of peptic ulcer perforation published after 1985 was undertaken. The short listed articles were

  14. Glove Perforations During Interventional Radiological Procedures

    International Nuclear Information System (INIS)

    Leena, R. V.; Shyamkumar, N. K.

    2010-01-01

    Intact surgical gloves are essential to avoid contact with blood and other body fluids. The objective of this study was to estimate the incidence of glove perforations during interventional radiological procedures. In this study, a total of 758 gloves used in 94 interventional radiological procedures were examined for perforations. Eleven perforations were encountered, only one of which was of occult type. No significant difference in the frequency of glove perforation was found between the categories with varying time duration.

  15. Helicobacter pylori in gastroduodenal perforation

    Directory of Open Access Journals (Sweden)

    Bharat B Dogra

    2014-01-01

    Full Text Available Background:peptic ulcers were earlier believed to be caused by dietary factors, gastric acid, and stress. However, in 1983, Warren and Marshall identified the correlation between Helicobacter pylori (H. pylori and peptic ulcers. It is now well established that most of the peptic ulcers occur as a result of H. pylori infection. But the co-relation between perforated peptic ulcer and H. pylori infection is not yet fully established. Aims and objectives : to study the prevalence of H. pylori infection in patients with perforated peptic ulcer. Materials and methods: this was a prospective study carried out in all cases of perforated peptic ulcer reporting in surgical wards of a medical college during 2008-2010. A total of 50 cases, presenting as acute perforation of duodenum and stomach during this period, formed the study group. After resuscitation, all the cases were subjected to emergency exploratory laparotomy. The exact site of perforation was identified, biopsy was taken from the ulcer margin from 2-3 sites and the tissue was sent for H. pylori culture and histopathological examination. Simple closure of perforation, omentoplasty, thorough peritoneal lavage and drainage was carried out. Results: out of the 50 cases of perforated peptic ulcer, 38 happened to be males, and only 12 were females. The age of the patients ranged from 20 to 70 years. All the patients underwent only emergency laparotomy. As many as 46 cases (92% turned out to be positive for H. pylori and only four cases (8% were negative for this infection. Postoperatively, patients who were found to be positive for H. pylori were put on anti-H. pylori treatment. Conclusion: there was a high prevalence of H. pylori infection in patients with perforated gastroduodenal ulcers.

  16. Spectrum of perforation peritonitis in delhi: 77 cases experience.

    Science.gov (United States)

    Yadav, Dinesh; Garg, Puneet K

    2013-04-01

    Perforation peritonitis is the most common surgical emergency encountered by surgeons all over the world as well in India. The spectrum of etiology of perforation peritonitis in tropical countries continues to differ from its western counterpart. This study was conducted at Hindu Rao Hospital, Municipal Corporation of Delhi, New Delhi, India, designed to highlight the spectrum of perforation peritonitis in the eastern countries and to improve its outcome. This prospective study included 77 consecutive patients of perforation peritonitis studied in terms of clinical presentations, causes, site of perforation, surgical treatment, postoperative complications, and mortality at Hindu Rao Hospital, Delhi, from March 1, 2011 to December 1, 2011, over a period of 8 months. All patients were resuscitated and underwent emergency exploratory laparotomy. On laparotomy cause of perforation peritonitis was found and controlled. The most common cause of perforation peritonitis noticed in our series was perforated duodenal ulcer (26.4 %) and ileal typhoid perforation (26.4 %), each followed by small bowel tuberculosis (10.3 %) and stomach perforation (9.2 %), perforation due to acute appendicitis (5 %). The highest number of perforations was seen in ileum (39.1 %), duodenum (26.4 %), stomach (11.5 %), appendix (3.5 %), jejunum (4.6 %), and colon (3.5 %). Overall mortality was 13 %. The spectrum of perforation peritonitis in India continuously differs from western countries. The highest number of perforations was noticed in the upper part of the gastrointestinal tract as compared to the western countries where the perforations seen mostly in the distal part. The most common cause of perforation peritonitis was perforated duodenal ulcer and small bowel typhoid perforation followed by typhoid perforation. Large bowel perforations and malignant perforations were least common in our setup.

  17. The management of large perforations of duodenal ulcers

    Directory of Open Access Journals (Sweden)

    Sharma Rajeev

    2005-06-01

    Full Text Available Abstract Background Duodenal ulcer perforations are a common surgical emergency, but literature is silent on the exact definition, incidence, management and complications of large perforations of duodenal ulcers. Methods The case files of 162 patients who underwent emergency laparotomy for duodenal ulcer perforations over a period of three years (2001 – 2003 were retrospectively reviewed and sorted into groups based on the size of the perforations – one group was defined as 'small 'perforations (less than 1 cm in diameter, another 'large' (when the perforation was more than 1 cm but less than 3 cms, and the third, 'giant'(when the perforation exceeded 3 cm. These groups of patients were then compared with each other in regard to the patient particulars, duration of symptoms, surgery performed and the outcome. Results A total of 40 patients were identified to have duodenal ulcer perforations more than 1 cm in size, thus accounting for nearly 25 % of all duodenal ulcer perforations operated during this period. These patients had a significantly higher incidence of leak, morbidity and mortality when compared to those with smaller perforations. Conclusion There are three distinct types of perforations of duodenal ulcers that are encountered in clinical practice. The first, are the 'small' perforations that are easy to manage and have low morbidity and mortality. The second are the 'large' perforations, that are also not uncommon, and omental patch closure gives the best results even in this subset of patients. The word 'giant' should be reserved for perforations that exceed 3 cms in diameter, and these are extremely uncommon.

  18. Laparoscopic pyloroplasty for perforated peptic ulcer.

    Science.gov (United States)

    Grišin, Edvard; Mikalauskas, Saulius; Poškus, Tomas; Jotautas, Valdemaras; Strupas, Kęstutis

    2017-09-01

    Peptic ulcer is a common disease affecting millions of people every year. Despite improved understanding and treatment of the disease, the number of patients admitted with duodenal peptic ulcer perforation has not decreased. Deaths from peptic ulcer disease overcome other common emergency situations. Laparoscopic repair of the perforated peptic ulcer (PPU) is the gold standard approach for simple perforation. However, in patients with large perforated chronic ulcers laparotomy with pyloroplasty is the standard treatment. It is generally accepted to perform open surgery in PPU emergencies because of the greater knowledge and experience gathered over the past decades and less potential harm for the patient or surgical complications. We present a case of successful laparoscopic pyloroplasty of a perforated duodenal ulcer with stenosis.

  19. CLINICAL STUDY OF DUODENAL PERFORATION

    Directory of Open Access Journals (Sweden)

    Sambasiva Rao

    2016-04-01

    Full Text Available BACKGROUND The duodenal injury can pose a formidable challenge to the surgeon and failure to manage it properly may have devastating results. Over the centuries, there was little to offer the patient of acute abdomen beyond cupping, purgation and enemas, all of which did more harm than good. It was not until 1884 that Mikulicz made an attempt to repair a perforation. Recent statistics indicate roughly 10% of population develop gastric or duodenal ulcer in life time. Roughly 1-3% of population above the age of 20 years have some degree of peptic ulcer activity during any annual period. A detailed history with regards to the signs and symptoms of the patient, a meticulous examination, radiological and biochemical investigations help to arrive at a correct preoperative diagnosis. In this study, a sincere effort has been put to understand the demographic patterns, to understand the underlying aetiology and to understand the effectiveness of the standard methods of investigation and treatment in use today. METHODS This is a 24 months prospective study i.e., from September 2011 to September 2013 carried out at Dr. Pinnamaneni Siddhartha Institute of Medical Sciences & Research Foundation. The study included the patients presenting to Dr. Pinnamaneni Siddhartha Institute of Medical Sciences & Research Foundation to emergency ward with signs and symptoms of hollow viscus perforation. The sample size included 30 cases of duodenal perforation. RESULTS Duodenal ulcer perforation commonly occurs in the age group of 30-60 years, but it can occur in any age group. Majority of the patients were male. Smoking and alcohol consumption were risk factors in most cases (53.3% for the causation of duodenal ulcer perforation. Sudden onset of abdominal pain, situated at epigastrium and right hypochondrium was a constant symptom (100%. Vomiting, constipation and fever were not so common. CONCLUSION The emergency surgical management for perforated duodenal ulcer is by

  20. Neutron detection in an atomic reactor core using semi-conductors; Detection des neutrons par semi-conducteur dans un coeur de reacteur atomique

    Energy Technology Data Exchange (ETDEWEB)

    Divoux, F [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1968-07-01

    In this paper, the first part describes the principle of nuclear particle detection by means of semiconductor diodes and the general application of these. The second part describes fabrication of the device used to estimate thermic neutron fluxes in core of a swimming pool type reactor. The useful volume (2.9 mm thickness) is in the light water moderator, between combustible elements plates. The results, principally obtained in the core of Siloette reactor at the 'Centre d'Etudes Nucleaires de Grenoble' at low power, are mentioned in the third part. Flux maps have been set and comparison between converter's products: Bore 10, Lithium 6, Uranium 235 is made. (author) [French] Dans ce rapport, une premiere partie porte sur la description du principe de detection des particules nucleaires par diodes a semi-conducteur et sur l'application generale de celles-ci. Une deuxieme partie s'attache a decrire la fabrication du materiel utilise pour evaluer les flux de neutrons thermiques dans un coeur de reacteur type pile piscine. L'espace de mesure (2,9 mm d'epaisseur) se situe entre les plaques des elements combustibles, dans le moderateur eau legere. Les resultats, obtenus principalement dans le coeur du reacteur Siloette du Centre d'Etudes Nucleaires de Grenoble aux basses puissances de fonctionnement, sont rapportes dans la troisieme partie. Des cartes de flux ont ete dressees et une comparaison est faite entre les produits 'convertisseurs' suivants: Bore 10, Lithium 6, Uranium 235. (auteur)

  1. A perforated diverticulum in Cushing's disease

    OpenAIRE

    de Havenon, Adam; Ehrenkranz, Joel

    2011-01-01

    We report a case of perforated colonic diverticulum in Cushing's disease. Although perforated diverticuli have been described in patients with Cushing's syndrome secondary to exogenous glucocorticoids, this complication has not been described in patients with Cushing's disease. Patients with hypercortisolism, from either exogenous or endogenous sources, should be monitored for diverticular perforation.

  2. CLINICAL STUDY AND MANAGEMENT OF BENIGN GASTROINTESTINAL PERFORATIONS

    Directory of Open Access Journals (Sweden)

    Kishan

    2016-05-01

    Full Text Available INTRODUCTION Peritonitis due to gastrointestinal perforation is one of the commonest surgical emergencies encountered by a general surgeon. (1,2 Mortality and morbidity is still very high despite early diagnosis and intensive management. This study is aimed to find common causes of perforations, its presentations, mode of investigations and treatment done and outcome of patients. METHODS Case records of all patients, in exclusion and inclusion criteria, who were admitted in emergency surgical ward with suspected GI perforation and peritonitis were included in study and diagnosis confirmed by either investigations preoperatively or by laparotomy and results analysed over a period of 16 months. RESULTS GI perforations due to benign causes are most common causes of peritonitis, of which gastroduodenal perforations are commonest followed by appendicular perforation closely followed by infective perforations. CONCLUSION Benign causes of upper gastroduodenal perforations are common causes of peritonitis (2,3. Mortality increases with delay in presentation and treatment. Abdominal signs like guarding rigidity are present in majority of cases. X-ray erect abdomen was effective in detecting perforation in majority of cases. Surgery is the treatment in all cases of perforation.

  3. Perforated peptic ulcer

    DEFF Research Database (Denmark)

    Søreide, Kjetil; Thorsen, Kenneth; Harrison, Ewen M

    2015-01-01

    Perforated peptic ulcer is a common emergency condition worldwide, with associated mortality rates of up to 30%. A scarcity of high-quality studies about the condition limits the knowledge base for clinical decision making, but a few published randomised trials are available. Although Helicobacter...... need further assessment. Adequate trials with low risk of bias are urgently needed to provide better evidence. We summarise the evidence for perforated peptic ulcer management and identify directions for future clinical research....

  4. Development of resonant detectors for epithermal neutron spectroscopy at pulsed neutron sources

    International Nuclear Information System (INIS)

    Tardocchi, M.; Pietropaolo, A.; Senesi, R.; Andreani, C.; Gorini, G.

    2004-01-01

    New perspectives for epithermal neutron spectroscopy are opened by the development of new detectors for inverse geometry time of flight spectrometers at pulsed neutron sources. One example is the Very Low Angle Detector (VLAD) bank planned to be delivered, within the next 4 years, within the eVERDI project, on the neutron spectrometer VESUVIO, at the ISIS pulsed neutron source (UK). VLAD will extend the (q,ω) kinematical region for neutron scattering to low wavefactor transfer (q -1 ) still keeping energy transfer >1 eV, thus allowing the investigations of new experimental studies in condensed matter systems. The technique being developed for detection of epithermal neutrons, within this low q and high-energy transfer region, is the Resonance Detection Technique. In this work, the state of the detector development will be presented with special focus on the results obtained with some prototype detectors, namely YAP scintillators and cadmium-zinc-telluride semiconductors

  5. Optimization of geometrical characteristics of perforated plates

    International Nuclear Information System (INIS)

    Radisavljevic, Igor; Balos, Sebastian; Nikacevic, Milutin; Sidjanin, Leposava

    2013-01-01

    Highlights: ► Perforated plate are tested against 12.7 mm API projectile. ► Perforations similar to the projectile diameter offer more efficient core fracture. ► Larger perforations gave a more efficient core fragmentation. ► SEM microscopy analysis has shown a ductile fracture mode at impact point. - Abstract: In this paper, an attempt was made to design effective non-homogenous armor in form of perforated plate mounted at close distance from basic armor plate. Perforated plate with three perforation diameters: 9, 10 and 11 mm, two ligaments length: 3.5 and 4.5 mm ligaments, set at 0° and 28° angles, were combined to 13 mm basic plate and tested against 12.7 mm API ammunition. It has been shown that larger perforations gave a more efficient core fragmentation, while angled specimens were the only ones that offer full protection against five API shots when the perforated plate was placed at 100 mm from the basic plate. Perforations that are similar in size to the penetrating core diameter offer a more efficient core fracture, leading to a faster fragment separation. This may enable a smaller distance between the add-on perforated and basic plate to be used. Scanning electron microscopy analysis has shown a ductile fracture mode at impact point, with hardness values on plate basic level. On the other hand, a brittle fracture mode with a rise in local hardness measured near impact point is a result of intensive high speed plastic deformation produced by bending stresses. A drop in local hardness measured near impact point, may be the result of intensive cracking that occur due to repeated projectile impact

  6. Development of the external cooling device of increase the productivity of neutron-transmutation-doped silicon semiconductor (NTD-Si) (Joint research)

    International Nuclear Information System (INIS)

    Hirose, Akira; Wada, Shigeru; Sasajima, Fumio; Kusunoki, Tsuyoshi; Kameyama, Iwao; Aizawa, Ryouji; Kikuchi, Naoyuki

    2007-01-01

    Neutron-Transmutation-Doped Silicon Semiconductor (hereinafter referred as 'NTD-Si') is the best semiconductor for the power device. The needs of NTD-Si increase recently in proportion to the popularization of hybrid-cars. A fission research reactor, which is a steady state neutron source, is being expected as the best device to meet the needs. So far, we have reconsidered the existing approach which is employed for NTD-Si production works at the research reactors JRR-3, JRR-4 and JMTR of JAEA so as to meet the needs. As one of the effective measures, we found out that the productivity can be increased by incorporating a new device to cool down radioactivity of irradiated silicon ingots at the place outside the main stream from the loading of silicon ingots to the withdrawal of irradiated ingots to the existing JRR-3 Uniformity Irradiation System. Consequently, we developed and installed the device (hereinafter referred as 'external cooling device'). After an ingot was irradiated once, it is turned over manually and irradiated again in order to irradiate the ingot uniformly. With the conventional system, it was necessary to wait the radioactivity of ingot decrease less than the permissible level with holding the ingot in the irradiation equipment. It was effective to shorten the waiting period by using an external cooling device for production increase of NTD-Si. It is expected that the productivity of NTD-Si will be increased by using the external cooling device. This report mentions the design of the external cooling device and verification between its design specifications and the performance of the device completed. (author)

  7. High sensitivity MOSFET-based neutron dosimetry

    International Nuclear Information System (INIS)

    Fragopoulou, M.; Konstantakos, V.; Zamani, M.; Siskos, S.; Laopoulos, T.; Sarrabayrouse, G.

    2010-01-01

    A new dosemeter based on a metal-oxide-semiconductor field effect transistor sensitive to both neutrons and gamma radiation was manufactured at LAAS-CNRS Laboratory, Toulouse, France. In order to be used for neutron dosimetry, a thin film of lithium fluoride was deposited on the surface of the gate of the device. The characteristics of the dosemeter, such as the dependence of its response to neutron dose and dose rate, were investigated. The studied dosemeter was very sensitive to gamma rays compared to other dosemeters proposed in the literature. Its response in thermal neutrons was found to be much higher than in fast neutrons and gamma rays.

  8. Device fabrication, characterization, and thermal neutron detection response of LiZnP and LiZnAs semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Montag, Benjamin W., E-mail: bmontag@ksu.edu; Ugorowski, Philip B.; Nelson, Kyle A.; Edwards, Nathaniel S.; McGregor, Douglas S.

    2016-11-11

    Nowotny-Juza compounds continue to be explored as candidates for solid-state neutron detectors. Such a device would have greater efficiency, in a compact form, than present day gas-filled {sup 3}He and {sup 10}BF{sub 3} detectors. The {sup 6}Li(n,t){sup 4}He reaction yields a total Q-value of 4.78 MeV, larger than {sup 10}B, an energy easily identified above background radiations. Hence, devices fabricated from semiconductor compounds having either natural Li (nominally 7.5% {sup 6}Li) or enriched {sup 6}Li (usually 95% {sup 6}Li) as constituent atoms may provide a material for compact high efficiency neutron detectors. Starting material was synthesized by preparing equimolar portions of Li, Zn, and As sealed under vacuum (10{sup −6} Torr) in quartz ampoules lined with boron nitride and subsequently reacted in a compounding furnace [1]. The raw synthesized material indicated the presence high impurity levels (material and electrical property characterizations). A static vacuum sublimation in quartz was performed to help purify the synthesized material [2,3]. Bulk crystalline samples were grown from the purified material [4,5]. Samples were cut using a diamond wire saw, and processed into devices. Bulk resistivity was determined from I–V curve measurements, ranging from 10{sup 6}–10{sup 11} Ω cm. Devices were characterized for sensitivity to 5.48 MeV alpha particles, 337 nm laser light, and neutron sensitivity in a thermal neutron diffracted beam at the Kansas State University TRIGA Mark II nuclear reactor. Thermal neutron reaction product charge induction was measured with a LiZnP device, and the reaction product spectral response was observed. - Highlights: • Devices were fabricated from in-house synthesized and purified LiZnAs and LiZnP. • Devices ranged in bulk resistivity from 10{sup 6}–10{sup 11} Ω cm. • Devices showed sensitivity to 5.48 MeV alpha particles. • Devices were characterized with a 337 nm laser light. • Devices were evaluated

  9. Multiple, Pan-Enteric Perforation Secondary to Intestinal Tuberculosis

    Science.gov (United States)

    Masood, Irfan; Majid, Zain; Rafiq, Ali; Rind, Waqas; Zia, Aisha; Raza, Sajjad

    2015-01-01

    Free perforation is one of the most feared complications of the intestinal tuberculosis. The terminal ileum is the most common site of perforation, while the majority of (90%) perforations are solitary. Herein, we describe a case of a 25-year-old male who presented with generalized peritonitis requiring an emergency exploratory laparotomy, which revealed pan-enteric perforation characterized by multiple perforations of the small bowel extending 10–15 cm from the DJ flexure up to the terminal ileum. The perforations were primarily closed, while 6–8 cm of the diseased terminal ileum was resected and the two ends were brought out as double-barreled ostomy. To the best of our knowledge, such an extensive tuberculous perforation of the small bowel has not been previously reported in the literature before. PMID:26798540

  10. Mortality risk factor analysis in colonic perforation: would retroperitoneal contamination increase mortality in colonic perforation?

    Science.gov (United States)

    Yoo, Ri Na; Kye, Bong-Hyeon; Kim, Gun; Kim, Hyung Jin; Cho, Hyeon-Min

    2017-10-01

    Colonic perforation is a lethal condition presenting high morbidity and mortality in spite of urgent surgical treatment. This study investigated the surgical outcome of patients with colonic perforation associated with retroperitoneal contamination. Retrospective analysis was performed for 30 patients diagnosed with colonic perforation caused by either inflammation or ischemia who underwent urgent surgical treatment in our facility from January 2005 to December 2014. Patient characteristics were analyzed to find risk factors correlated with increased postoperative mortality. Using the Physiological and Operative Severity Score for the Enumeration of Mortality and Morbidity (POSSUM) audit system, the mortality and morbidity rates were estimated to verify the surgical outcomes. Patients with retroperitoneal contamination, defined by the presence of retroperitoneal air in the preoperative abdominopelvic CT, were compared to those without retroperitoneal contamination. Eight out of 30 patients (26.7%) with colonic perforation had died after urgent surgical treatment. Factors associated with mortality included age, American Society of Anesthesiologists (ASA) physical status classification, and the ischemic cause of colonic perforation. Three out of 6 patients (50%) who presented retroperitoneal contamination were deceased. Although the patients with retroperitoneal contamination did not show significant increase in the mortality rate, they showed significantly higher ASA physical status classification than those without retroperitoneal contamination. The mortality rate predicted from Portsmouth POSSUM was higher in the patients with retroperitoneal contamination. Patients presenting colonic perforation along with retroperitoneal contamination demonstrated severe comorbidity. However, retroperitoneal contamination was not found to be correlated with the mortality rate.

  11. Multiple, Pan-Enteric Perforation Secondary to Intestinal Tuberculosis

    Directory of Open Access Journals (Sweden)

    Irfan Masood

    2015-01-01

    Full Text Available Free perforation is one of the most feared complications of the intestinal tuberculosis. The terminal ileum is the most common site of perforation, while the majority of (90% perforations are solitary. Herein, we describe a case of a 25-year-old male who presented with generalized peritonitis requiring an emergency exploratory laparotomy, which revealed pan-enteric perforation characterized by multiple perforations of the small bowel extending 10–15 cm from the DJ flexure up to the terminal ileum. The perforations were primarily closed, while 6–8 cm of the diseased terminal ileum was resected and the two ends were brought out as double-barreled ostomy. To the best of our knowledge, such an extensive tuberculous perforation of the small bowel has not been previously reported in the literature before.

  12. STUDY OF CLINICAL OUTCOMES OF SUBFASCIAL PERFORATOR LIGATION SURGERY IN PERFORATOR INCOMPETENCE

    Directory of Open Access Journals (Sweden)

    Vasuki Rajam

    2017-02-01

    Full Text Available BACKGROUND Chronic venous insufficiency presents with a spectrum of clinical features ranging from pain or heaviness of affected limbs to non-healing ulcers over the lower limbs and usually require some form of surgical intervention, performing direct perforator vein division preferably by subfascial endoscopic perforator ligation surgery for perforator incompetence, as despite aggressive conservative therapy including compression, lifestyle modification and venotonic medications which are of high cost treatment with increased risk of increasing symptoms. MATERIALS AND METHODS A prospective longitudinal clinical study of 30 patients selected by systematic sampling method from November 2014 to September 2015 at our institution was conducted to determine the results of subfascial endoscopic perforator vein surgery (SEPS in perforator incompetence. RESULTS For venous clinical severity scoring pre operatively and after 3 weeks post-surgery, the mean for VCSS pre-operatively was 6.66 and a standard deviation of 2.399. The T value was calculated and was found to be 4.9321 and p value of 0.00001(p value less than 0.05 is significant. Similarly for the cases with active ulcer, the size assessment pre-operatively and post-SEPS was again analysed using student t test and the mean ulcer size prior to surgery was found to be 3.3 and standard deviation of 1.984. The T value was calculated and was found to be 1.789009 and a p value of 0.04 (p value less than 0.05 is significant. CONCLUSION Our study concluded that favourable and significant ulcer healing rate with improvement and reduction in clinical severity suggests that SEPS plays an important role in surgical management of advanced stages of venous insufficiency.

  13. Tricholithobezoar Causing Gastric Perforation

    Directory of Open Access Journals (Sweden)

    Juliana Santos Valenciano

    2012-01-01

    Full Text Available A bezoar is an intraluminal mass formed by the accumulation of undigested material in the gastrointestinal tract. Trichobezoar is a rare condition seen almost exclusively in young women with trichotillomania and trichotillophagia. When not recognized, the trichobezoar continues to grow, which increases the risk of severe complications such as gastric ulceration and even perforation. Formation of a gallstone within the trichobezoar (tricholithobezoar is an event that has not yet been described. We report the case of a 22-year-old woman admitted to the emergency room with signals and symptoms of an epigastric mass and perforative acute abdomen. Radiological study revealed bilateral pneumoperitoneum. Personal history revealed depressive syndrome, trichotillomania and trichophagia. With a diagnosis of visceral perforation, an urgent exploratory laparotomy was performed. This confirmed the diagnosis of gastric perforation due to a large trichobezoar with the formation of a gastrolith that was removed by anterior gastrotomy. Biochemical study of the gastric stone revealed that it was composed of bile salts. There were no complications. The patient was discharged on the 5th postoperative day and was referred for psychiatric treatment.

  14. Clinical applications of the superior epigastric artery perforator (SEAP) flap: anatomical studies and preoperative perforator mapping with multidetector CT.

    Science.gov (United States)

    Hamdi, Moustapha; Van Landuyt, Koenraad; Ulens, Sara; Van Hedent, Eddy; Roche, Nathalie; Monstrey, Stan

    2009-09-01

    Pedicled superior epigastric artery perforator (SEAP) flaps can be raised to cover challenging thoracic defects. We present an anatomical study based on multidetector computerized tomography (MDCT) scan findings of the SEA perforators in addition to the first reported clinical series of SEAP flaps in anterior chest wall reconstruction. (a) In the CT scan study, images of a group of 20 patients who underwent MDCT scan analysis were used to visualise bilaterally the location of musculocutaneous SEAP. X- and Y-axes were used as landmarks to localise the perforators. The X-axis is a horizontal line at the junction of sternum and xyphoid (JCX) and the Y-axis is at the midline. (b) In the clinical study, seven pedicled SEAP flaps were performed in another group of patients. MDCT images revealed totally 157 perforators with a mean of 7.85 perforators per patient. The dominant perforators (137 perforators) were mainly localised in an area between 1.5 and 6.5 cm from the X-axis on both sides and between 3 and 16 cm below the Y-axis. The calibre of these dominant perforators was judged as 'good' to 'very good' in 82.5% of the cases. The average dimension of the flap was 21.7x6.7 cm. All flaps were based on one perforator. Mean harvesting time was 110 min. There were no flap losses. Minor tip necrosis occurred in two flaps. One of them was treated with excision and primary closure. Our clinical experience indicates that the SEAP flap provides a novel and useful approach for reconstruction of anterior chest wall defects. CT-based imaging allows for anatomical assessment of the perforators of the superior epigastric artery (SEA).

  15. Research on the Perforating Algorithm Based on STL Files

    Science.gov (United States)

    Yuchuan, Han; Xianfeng, Zhu; Yunrui, Bai; Zhiwen, Wu

    2018-04-01

    In the process of making medical personalized external fixation brace, the 3D data file should be perforated to increase the air permeability and reduce the weight. In this paper, a perforating algorithm for 3D STL file is proposed, which can perforate holes, hollow characters and engrave decorative patterns on STL files. The perforating process is composed of three steps. Firstly, make the imaginary space surface intersect with the STL model, and reconstruct triangles at the intersection. Secondly, delete the triangular facets inside the space surface and make a hole on the STL model. Thirdly, triangulate the inner surface of the hole, and thus realize the perforating. Choose the simple space equations such as cylindrical and rectangular prism equations as perforating equations can perforate round holes and rectangular holes. Through the combination of different holes, lettering, perforating decorative patterns and other perforated results can be accomplished. At last, an external fixation brace and an individual pen container were perforated holes using the algorithm, and the expected results were reached, which proved the algorithm is feasible.

  16. Water distribution in an orchard irrigated by perforated distributors in stony ground

    International Nuclear Information System (INIS)

    Decroix, M.; Marcesse, J.; Normand, M.

    1975-01-01

    In the context of new irrigation techniques the Compagnie Nationale d'Amenagement du Bas-Rhone et du Languedoc (B.Rh.L.) has developed a process of localized irrigation by perforated distributors. Conditions were defined for the optimum use of this process, especially the distribution of water in the ground. The study was carried out in a peach orchard in stony ground. The neutronic method was used to measure the soil moisture content. Because of the heterogeneous stone size distribution it was necessary for the specific humidity determination to take into account the dry apparent density. This parameter was measured by gammametry [fr

  17. Spectrum of perforation peritonitis in Pakistan: 300 cases Eastern experience.

    Science.gov (United States)

    Afridi, Shahida Parveen; Malik, Faiza; Ur-Rahman, Shafiq; Shamim, Shahid; Samo, Khursheed A

    2008-11-08

    Perforation peritonitis is the most common surgical emergency encountered by the surgeons all over the world as well in Pakistan. The spectrum of etiology of perforation peritonitis in tropical countries continues to differ from its western counter part. This study was conducted at Dow University of health sciences and Civil Hospital Karachi (DUHS & CHK) Pakistan, designed to highlight the spectrum of perforation peritonitis in the East and to improve its outcome. A prospective study includes three hundred consecutive patients of perforation peritonitis studied in terms of clinical presentations, Causes, site of perforation, surgical treatment, post operative complications and mortality, at (DUHS&CHK) Pakistan, from 1st September 2005 - 1st March 2008, over a period of two and half years. All patients were resuscitated underwent emergency exploratory laparotomy. On laparotomy cause of perforation peritonitis was found and controlled. The most common cause of perforation peritonitis noticed in our series was acid peptic disease 45%, perforated duodenal ulcer (43.6%) and gastric ulcer 1.3%. followed by small bowel tuberculosis (21%) and typhoid (17%). large bowel perforation due to tuberculosis 5%, malignancy 2.6% and volvulus 0.3%. Perforation due to acute appendicitis (5%). Highest number of perforations has seen in the duodenum 43.6%, ileum37.6%, and colon 8%, appendix 5%, jejunum 3.3%, and stomach 2.3%. Overall mortality was (10.6%). The spectrum of perforation peritonitis in Pakistan continuously differs from western country. Highest number of perforations noticed in the upper part of the gastrointestinal tract as compared to the western countries where the perforations seen mostly in the distal part. Most common cause of perforation peritonitis is perforated duodenal ulcer, followed by small bowel tuberculosis and typhoid perforation. Majority of the large bowel perforations are also tubercular. Malignant perforations are least common in our setup.

  18. Spectrum of perforation peritonitis in Pakistan: 300 cases Eastern experience

    Directory of Open Access Journals (Sweden)

    Ur-Rahman Shafiq

    2008-11-01

    Full Text Available Abstract Background Perforation peritonitis is the most common surgical emergency encountered by the surgeons all over the world as well in Pakistan. The spectrum of etiology of perforation peritonitis in tropical countries continues to differ from its western counter part. This study was conducted at Dow University of health sciences and Civil Hospital Karachi (DUHS & CHK Pakistan, designed to highlight the spectrum of perforation peritonitis in the East and to improve its outcome. Methods A prospective study includes three hundred consecutive patients of perforation peritonitis studied in terms of clinical presentations, Causes, site of perforation, surgical treatment, post operative complications and mortality, at (DUHS&CHK Pakistan, from 1st September 2005 – 1st March 2008, over a period of two and half years. All patients were resuscitated underwent emergency exploratory laparotomy. On laparotomy cause of perforation peritonitis was found and controlled. Results The most common cause of perforation peritonitis noticed in our series was acid peptic disease 45%, perforated duodenal ulcer (43.6% and gastric ulcer 1.3%. followed by small bowel tuberculosis (21% and typhoid (17%. large bowel perforation due to tuberculosis 5%, malignancy 2.6% and volvulus 0.3%. Perforation due to acute appendicitis (5%. Highest number of perforations has seen in the duodenum 43.6%, ileum37.6%, and colon 8%, appendix 5%, jejunum 3.3%, and stomach 2.3%. Overall mortality was (10.6%. Conclusion The spectrum of perforation peritonitis in Pakistan continuously differs from western country. Highest number of perforations noticed in the upper part of the gastrointestinal tract as compared to the western countries where the perforations seen mostly in the distal part. Most common cause of perforation peritonitis is perforated duodenal ulcer, followed by small bowel tuberculosis and typhoid perforation. Majority of the large bowel perforations are also tubercular

  19. Colonic perforation following endoscopic retrograde ...

    African Journals Online (AJOL)

    She developed severe upper abdominal pain after the ... non-surgical management of pancreatitis and associated complications, colonic perforation should be considered in patients who deteriorate ... To our knowledge this is the first case of a secure pre-operative diagnosis of colonic perforation due to to pancreatitis.

  20. A portable and wide energy range semiconductor-based neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Hoshor, C.B. [Department of Physics, University of Missouri, Kansas City, MO (United States); Oakes, T.M. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Myers, E.R.; Rogers, B.J.; Currie, J.E.; Young, S.M.; Crow, J.A.; Scott, P.R. [Department of Physics, University of Missouri, Kansas City, MO (United States); Miller, W.H. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Missouri University Research Reactor, Columbia, MO (United States); Bellinger, S.L. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Sobering, T.J. [Electronics Design Laboratory, Kansas State University, Manhattan, KS (United States); Fronk, R.G.; Shultis, J.K.; McGregor, D.S. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Caruso, A.N., E-mail: carusoan@umkc.edu [Department of Physics, University of Missouri, Kansas City, MO (United States)

    2015-12-11

    Hand-held instruments that can be used to passively detect and identify sources of neutron radiation—either bare or obscured by neutron moderating and/or absorbing material(s)—in real time are of interest in a variety of nuclear non-proliferation and health physics applications. Such an instrument must provide a means to high intrinsic detection efficiency and energy-sensitive measurements of free neutron fields, for neutrons ranging from thermal energies to the top end of the evaporation spectrum. To address and overcome the challenges inherent to the aforementioned applications, four solid-state moderating-type neutron spectrometers of varying cost, weight, and complexity have been designed, fabricated, and tested. The motivation of this work is to introduce these novel human-portable instruments by discussing the fundamental theory of their operation, investigating and analyzing the principal considerations for optimal instrument design, and evaluating the capability of each of the four fabricated spectrometers to meet the application needs.

  1. A portable and wide energy range semiconductor-based neutron spectrometer

    International Nuclear Information System (INIS)

    Hoshor, C.B.; Oakes, T.M.; Myers, E.R.; Rogers, B.J.; Currie, J.E.; Young, S.M.; Crow, J.A.; Scott, P.R.; Miller, W.H.; Bellinger, S.L.; Sobering, T.J.; Fronk, R.G.; Shultis, J.K.; McGregor, D.S.; Caruso, A.N.

    2015-01-01

    Hand-held instruments that can be used to passively detect and identify sources of neutron radiation—either bare or obscured by neutron moderating and/or absorbing material(s)—in real time are of interest in a variety of nuclear non-proliferation and health physics applications. Such an instrument must provide a means to high intrinsic detection efficiency and energy-sensitive measurements of free neutron fields, for neutrons ranging from thermal energies to the top end of the evaporation spectrum. To address and overcome the challenges inherent to the aforementioned applications, four solid-state moderating-type neutron spectrometers of varying cost, weight, and complexity have been designed, fabricated, and tested. The motivation of this work is to introduce these novel human-portable instruments by discussing the fundamental theory of their operation, investigating and analyzing the principal considerations for optimal instrument design, and evaluating the capability of each of the four fabricated spectrometers to meet the application needs.

  2. Applications of neutrons for laboratory and industrial activation analysis problems

    International Nuclear Information System (INIS)

    Szabo, Elek; Bakos, Laszlo

    1986-01-01

    This chapter presents some particular applications and case studies of neutrons in activation analysis for research and industrial development purposes. The reactor neutrons have been applied in Hungarian laboratories for semiconductor research, for analysis of geological (lunar) samples, and for a special comparator measurement of samples. Some industrial applications of neutron generator and sealed sources for analytical problems are presented. Finally, prompt neutron activation analysis is outlined briefly. (R.P.)

  3. Radiologic Study of Meniscus Perforations in the Temporomandibular Joint

    International Nuclear Information System (INIS)

    Kim, Kee Duck; Park, Chang Seo

    1990-01-01

    Thirty-nine patients (forty-four joints) who had been diagnosed as having meniscus perforation of the temporomandibular joint by inferior joint space arthrography and had been treated by surgical procedures were evaluated retrospectively. Information of clinical findings, arthrotomographic findings and surgical findings was collected on a standardized form and evaluated. The results were as follows: 1. On the 34 patients of 38 joints which were surgically confirmed perforation of meniscus or its attachments of the temporomandibular joint, there were 29 females and 5 males (5.8:1). The average age was 36 years (range 17 to 70). 2. The common clinical findings of group that had meniscus displacement without reduction and with perforation were pain on the affected joint and limitation of mouth opening. In the group showing meniscus displacement with reduction and with perforation the common clinical findings were pain and clicking on the affected joint. 3. 32 joints (84.2%) were arthrotomographically anterior meniscus displacement without reduction and with perforation, 6 joints (15.8%) showed anterior meniscus displacement with reduction and with perforation. 4. Joints categorized arthrotomographically as having meniscus displacement without reduction and with perforation were less likely to have full translation of the condyle in comparison with the normal or meniscus displacement with reduction and with perforation groups (p<0.05) 5. The arthrographic findings of 44 joints having meniscus perforation were compared with surgical findings, there were 6 false positive findings of meniscus perforation, the reliability of arthrographic findings of meniscus perforation was a 86.4% correlation with surgical findings. 6. On the site of perforations of 38 joints which were surgically confirmed perforation of meniscus or its attachments, twenty-three of perforations (60.5%) were in location at the junction of the meniscus and posterior attachment, fourteen (36.9%) were

  4. Isolated jejunal perforation following blunt abdominal trauma

    Directory of Open Access Journals (Sweden)

    Ahmet Pergel

    2012-09-01

    Full Text Available Isolated perforation of the jejunum, following blunt abdominaltrauma, is extremely rare. These injuries aredifficult to diagnose because initial clinical signs are frequentlynonspecific and a delay in treatment increasesmortality and morbidity of the patients. Conventional radiogramsare often inadequate for diagnosing this subsetof trauma. For an accurate and timely diagnosis, thepossibility of bowel perforation and the need for repeatedexaminations should be kept in mind. Herein, we presenta 28-year-old man with isolated jejunal perforation followingblunt abdominal trauma.Key words: Blunt abdominal trauma, isolated jejunal perforation,early diagnosis

  5. Perforated peptic ulcer.

    Science.gov (United States)

    Søreide, Kjetil; Thorsen, Kenneth; Harrison, Ewen M; Bingener, Juliane; Møller, Morten H; Ohene-Yeboah, Michael; Søreide, Jon Arne

    2015-09-26

    Perforated peptic ulcer is a common emergency condition worldwide, with associated mortality rates of up to 30%. A scarcity of high-quality studies about the condition limits the knowledge base for clinical decision making, but a few published randomised trials are available. Although Helicobacter pylori and use of non-steroidal anti-inflammatory drugs are common causes, demographic differences in age, sex, perforation location, and underlying causes exist between countries, and mortality rates also vary. Clinical prediction rules are used, but accuracy varies with study population. Early surgery, either by laparoscopic or open repair, and proper sepsis management are essential for good outcome. Selected patients can be managed non-operatively or with novel endoscopic approaches, but validation of such methods in trials is needed. Quality of care, sepsis care bundles, and postoperative monitoring need further assessment. Adequate trials with low risk of bias are urgently needed to provide better evidence. We summarise the evidence for perforated peptic ulcer management and identify directions for future clinical research. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. [Saphenous perforator flap].

    Science.gov (United States)

    Winkel, R; Tajsic, N; Husum, H; Schlageter, M; Hanebuth, G; Hoffmann, R

    2013-04-01

    Replacement of full thickness soft tissue defects in the lower leg and ankle, appropriate to the defect and following the course of blood vessels feeding the skin of a distally hinged fasciocutaneous flap most reliably based on the individual anatomy of distal perforators of the posterior tibial artery. Full thickness soft tissue defects, up to 12 cm in length and up to 8 cm in width. Sufficient vascularization of the foot required, in osteomyelitis, and when joints, fractures, implants and tendons are exposed and when a split skin graft, a local flap, a suralis perforator flap or a free flap is not indicated. For patients, in whom a 1-2 h operation is not possible; necessity of angioplasty; decollement or scars around the distal perforators of the posterior tibial artery; local infection or necrosis of soft tissues and/or bone, which cannot be totally excised. Radical debridement; flap dissection without tourniquet; microdissection; design of the flap on the skin: pivot point ~ 10 cm (6-14 cm) proximal of the tip of the medial malleolus; base ~ 5 cm in width, between the course of the saphenous nerve and of the great saphenous vein and the Achilles tendon; adipofascial pedicle up to 15 cm in length sited over the septum between soleus and flexor digitorum muscles, following the course of the saphenous nerve, with a central skin stripe, which expands into a proximal skin island; skin island is outlined similar to the defect, but larger by 1 to 2 cm, surrounded by an adipofascial border: adjustment of the planning as well as of the elevation of these flaps according to the individual position and the caliber of perforators requires in each case the search for a perforator at the estimated pivot point. Delay of transposition, if the division of more than one perforator proximal to the pivot point obviously diminishes circulation. No "tunnelling "of the pedicle; defects of skin due to the elevation of the flap are replaced by split and meshed skin grafts or temporary

  7. Perforated marginal ulcers after laparoscopic gastric bypass.

    Science.gov (United States)

    Felix, Edward L; Kettelle, John; Mobley, Elijah; Swartz, Daniel

    2008-10-01

    Perforated marginal ulcer (PMU) after laparoscopic Roux-en-Y gastric bypass (LRYGB) is a serious complication, but its incidence and etiology have rarely been investigated. Therefore, a retrospective review of all patients undergoing LRYGB at the authors' center was conducted to determine the incidence of PMU and whether any causative factors were present. A prospectively kept database of all patients at the authors' bariatric center was retrospectively reviewed. The complete records of patients with a PMU were examined individually for accuracy and analyzed for treatment, outcome, and possible underlying causes of the marginal perforation. Between April 1999 and August 2007, 1% of the patients (35/3,430) undergoing laparoscopic gastric bypass experienced one or more perforated marginal ulcers 3 to 70 months (median, 18 months) after LRYGB. The patients with and without perforation were not significantly different in terms of mean age (37 vs 41 years), weight (286 vs 287 lb), body mass index (BMI) (46 vs 47), or female gender (89% vs 83%). Of the patients with perforations, 2 (6%) were taking steroids, 10 (29%) were receiving nonsteroidal antiinflammatory drugs (NSAIDs) at the time of the perforation, 18 (51%) were actively smoking, and 6 of the smokers also were taking NSAIDs. Eleven of the patients (31%) who perforated did not have at least one of these possible risk factors, but 4 (36%) of the 11 patients in this group had been treated after bypass for a marginal ulcer. Only 7 (20%) of the 35 patients who had laparoscopic bypass, or 7 (0.2%) in the entire group of 3,430 patients, perforated without any warning. There were no deaths, but three patients reperforated. The incidence of a marginal ulcer perforating after LRYGB was significant (>1%) and appeared to be related to smoking or the use of NSAIDs or steroids. Because only 0.2% of all patients acutely perforated without some risk factor or warning, long-term ulcer prophylaxis or treatment may be necessary

  8. A Study on the Thermal Neutron Filter for the Irradiation of Electronic Materials at HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seong Woo; Kim, Sung Ryul; Park, Seung Jae; Shin, Yoon Taeg; Cho, Man Soon; Cho, Kee Nam [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The representative example is a technique of making the semiconductor with the transmutation using the pure Si. This NTD (Neutron Transmutation Doping) Si is used as a high-quality semiconductor because it has a uniform resistance. Likewise, the electronic materials are being investigated to improve the performance of material using the neutron irradiation method. The mechanism for reaction between the electronic materials and the neutrons depends on the energy of the neutron. Capturing reaction by thermal neutrons causes the transmutation and a lot of defects are made by fast neutrons. The study for the effect by such neutron energy is necessary to understand the performance improvement of the irradiated electronic materials. The thermal neutron filter was investigated to be used for the irradiation of electronic materials at HANARO. IP irradiation hole was selected and the irradiation device was designed. The analysis was conducted considering four candidate materials.

  9. Imaging gastrointestinal perforation in pediatric blunt abdominal trauma

    International Nuclear Information System (INIS)

    Jamieson, D.H.; Babyn, P.S.; Pearl, R.

    1996-01-01

    Objective. To assess the role of imaging, in particular CT, in the early detection of GI perforation. Subjects and methods. In a 10-year period, 43 patients with surgically confirmed GI perforation were identified from hospital records; 22 of these had preoperative CT evaluation. Medical records and radiology were retrospectively reviewed and CT studies were particularly assessed for extraluminal air, free intraperitoneal fluid, bowel wall thickening, bowel wall enhancement, and bowel dilatation. During the study period an additional 12 trauma patients were identified who had CT studies demonstrating the above findings, but who had hypovolemic shock bowel or nondisrupting bowel injury without perforation evident. Results. Extraluminal air was demonstrated in 47 % of the imaged perforations. There was one false-positive extraluminal air. Perforation was confirmed in patients who had all five of the above CT findings, but this was the case for only 18 % of patients with perforation. One or more of the five specified CT findings were present in all CT studies reviewed. No false-negative CT study was performed in the study period. Conclusion. Separating nondisrupting bowel injury from perforation is diagnostically difficult; however, CT remains a good modality for assessing GI perforation in pediatric blunt trauma, but it cannot replace diligent and repeated clinical evaluation of all potential perforation victims. (orig.). With 4 figs., 1 tab

  10. Experimental perforation of tubing with a hydraulic sand jet

    Energy Technology Data Exchange (ETDEWEB)

    Semenov, Yu V

    1970-01-01

    A series of field tests has shown that perforation with a hydraulic sand jet improves the quality of well completion. The sand jet does not crack the cement sheath or the casing, and the perforations are larger and deeper than perforations formed by explosive charges. Fluid circulation during sand jet perforation can safely be stopped for at least 10 min. Water containing a surfactant can be used as a sand carrier. Sand jet perforation allows successful completion of wells cased by 2 tubing strings. Sand jet perforation can be used to clean the borehole well and to remove foreign objects from the well.

  11. Isotopically controlled semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Haller, Eugene E.

    2006-06-19

    The following article is an edited transcript based on the Turnbull Lecture given by Eugene E. Haller at the 2005 Materials Research Society Fall Meeting in Boston on November 29, 2005. The David Turnbull Lectureship is awarded to recognize the career of a scientist who has made outstanding contributions to understanding materials phenomena and properties through research, writing, and lecturing, as exemplified by the life work of David Turnbull. Haller was named the 2005 David Turnbull Lecturer for his 'pioneering achievements and leadership in establishing the field of isotopically engineered semiconductors; for outstanding contributions to materials growth, doping and diffusion; and for excellence in lecturing, writing, and fostering international collaborations'. The scientific interest, increased availability, and technological promise of highly enriched isotopes have led to a sharp rise in the number of experimental and theoretical studies with isotopically controlled semiconductor crystals. This article reviews results obtained with isotopically controlled semiconductor bulk and thin-film heterostructures. Isotopic composition affects several properties such as phonon energies, band structure, and lattice constant in subtle, but, for their physical understanding, significant ways. Large isotope-related effects are observed for thermal conductivity in local vibrational modes of impurities and after neutron transmutation doping. Spectacularly sharp photoluminescence lines have been observed in ultrapure, isotopically enriched silicon crystals. Isotope multilayer structures are especially well suited for simultaneous self- and dopant-diffusion studies. The absence of any chemical, mechanical, or electrical driving forces makes possible the study of an ideal random-walk problem. Isotopically controlled semiconductors may find applications in quantum computing, nanoscience, and spintronics.

  12. Perforated Sigmoid Diverticular Disease: a Management Protocol

    Science.gov (United States)

    Moin, Thajammul

    2008-01-01

    Background: To develop an evidence-based protocol for the management of perforated sigmoid diverticular disease. Methods: A search of the literature was undertaken. All publications pertaining to perforated sigmoid diverticular disease were analyzed and then categorized according to their level of evidence. Recommendations were then made on the basis of this. Results: Multiple case reports suggest that primary closure of perforation of sigmoid diverticula is safe in the absence of peritoneal contamination. Conclusions: A 2-stage laparoscopic approach incorporating the principles of damage limitation surgery may be a safe strategy in the management of perforated diverticular disease. PMID:18435896

  13. Perforator anatomy of the ulnar forearm fasciocutaneous flap.

    Science.gov (United States)

    Mathy, Jon A; Moaveni, Zachary; Tan, Swee T

    2012-08-01

    The ulnar forearm fasciocutaneous flap (UFFF) is a favourable alternative to the radial forearm flap when thin and pliable tissue is required. The precise anatomy of the cutaneous perforators of UFFF has not been previously reported. The position of cutaneous perforators>0.5 mm was recorded while raising 52 consecutive free UFFFs in 51 patients at our Centre. Three (6%) UFFFs in two patients demonstrated direct cutaneous supply through a superficial ulnar artery, a known anatomic variance. There was no cutaneous perforator>0.5 mm in one flap. Among the remaining 48 dissections, an average of 3 (range, 1-6) cutaneous perforators were identified. Ninety-four percent of these forearms demonstrated at least one perforator>0.5 mm within 3 cm, and all had at least one perforator within 6 cm of the midpoint of the forearm. Proximal perforators were more likely to be musculo-cutaneous through the edge of flexor carpi ulnaris or flexor digitorum superficialis, while mid- to distal perforators were septo-cutaneous. UFFF skin paddle designed to overlie an area within 3 cm of the midpoint between the medial epicondyle and the pisiform is most likely to include at least one cutaneous perforator from the ulnar artery, without a need for intra-operative skin island adjustment. This novel anatomic finding and other practical generalisations are discussed to facilitate successful elevation of UFFF. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Perforated gastric carcinoma in a young-age patient

    Directory of Open Access Journals (Sweden)

    Feng-Hsu Wu

    2018-06-01

    Full Text Available Perforation is a rare complication of gastric carcinoma, and it occurs in less than 5% of all gastric carcinoma cases and in less than 1% within all acute abdomen cases. The diagnosis of malignancy is usually not validated preoperatively. In previous reported English literature, all patients with perforated gastric cancer have the feature of old age. This feature might be able to guide the surgeon to impress the differential diagnosis of malignancy before or during the emergent operation of gastric perforation.This 32-year-old male patient suffered from sudden onset of epigastric pain. We performed emergent operation under the impression of hollow organ perforation. The postoperative pathologic report of gastric ulcer revealed gastric carcinoma. We performed second-stage operation of total gastrectomy with D2 lymphadenectomy smoothly 7 days later. As we know, this is the youngest patient having the condition of perforated gastric carcinoma reported in the literature. This case reminds us that it is possible for perforated gastric carcinoma to occur in young-age patients. Keywords: Gastric cancer, Acute abdomen, Gastric perforation

  15. Neutron Imaging with Timepix Coupled Lithium Indium Diselenide

    Directory of Open Access Journals (Sweden)

    Elan Herrera

    2017-12-01

    Full Text Available The material lithium indium diselenide, a single crystal neutron sensitive semiconductor, has demonstrated its capabilities as a high resolution imaging device. The sensor was prepared with a 55 μ m pitch array of gold contacts, designed to couple with the Timepix imaging ASIC. The resulting device was tested at the High Flux Isotope Reactor, demonstrating a response to cold neutrons when enriched in 95% 6 Li. The imaging system performed a series of experiments resulting in a <200 μ m resolution limit with the Paul Scherrer Institute (PSI Siemens star mask and a feature resolution of 34 μ m with a knife-edge test. Furthermore, the system was able to resolve the University of Tennessee logo inscribed into a 3D printed 1 cm 3 plastic block. This technology marks the application of high resolution neutron imaging using a direct readout semiconductor.

  16. PERFORATED PEPTIC ULCER: A CLINICAL ANALYSIS AND OUTCOME

    OpenAIRE

    Bijit

    2016-01-01

    BACKGROUND The incidence of perforated peptic ulcer is approximately 7-10 cases per one lakh population per year. Perforation is seen in about 7% of patients hospitalized for peptic ulcer disease. Peptic ulcer perforation, which can be gastric/duodenal perforation can be a serious life-threatening condition if not detected early and treated urgently. Peptic ulcer disease has decreased considerably worldwide with the advent of potent anti-ulcer medicines, but its complication l...

  17. Perforated membrane-type acoustic metamaterials

    International Nuclear Information System (INIS)

    Langfeldt, F.; Kemsies, H.; Gleine, W.; Estorff, O. von

    2017-01-01

    This letter introduces a modified design of membrane-type acoustic metamaterials (MAMs) with a ring mass and a perforation so that an airflow through the membrane is enabled. Simplified analytical investigations of the perforated MAM (PMAM) indicate that the perforation introduces a second anti-resonance, where the effective surface mass density of the PMAM is much higher than the static value. The theoretical results are validated using impedance tube measurements, indicating good agreement between the theoretical predictions and the measured data. The anti-resonances yield high low-frequency sound transmission loss values with peak values over 25 dB higher than the corresponding mass-law. - Highlights: • A new membrane-type acoustic metamaterial exhibiting negative density is presented. • The metamaterial design contains a ring mass with a perforation through the membrane. • The sound transmission loss exhibits narrow-band peaks much higher than the mass-law. • The emergence of the peaks is explained using a simple theoretical model. • Impedance tube measurements are used to validate the theoretical predictions.

  18. Perforated membrane-type acoustic metamaterials

    Energy Technology Data Exchange (ETDEWEB)

    Langfeldt, F., E-mail: Felix.Langfeldt@haw-hamburg.de [Department of Automotive and Aeronautical Engineering, Hamburg University of Applied Sciences, Berliner Tor 9, D-20099 Hamburg (Germany); Kemsies, H., E-mail: Hannes.Kemsies@haw-hamburg.de [Department of Automotive and Aeronautical Engineering, Hamburg University of Applied Sciences, Berliner Tor 9, D-20099 Hamburg (Germany); Gleine, W., E-mail: Wolfgang.Gleine@haw-hamburg.de [Department of Automotive and Aeronautical Engineering, Hamburg University of Applied Sciences, Berliner Tor 9, D-20099 Hamburg (Germany); Estorff, O. von, E-mail: estorff@tu-harburg.de [Institute of Modelling and Computation, Hamburg University of Technology, Denickestr. 17, D-21073 Hamburg (Germany)

    2017-04-25

    This letter introduces a modified design of membrane-type acoustic metamaterials (MAMs) with a ring mass and a perforation so that an airflow through the membrane is enabled. Simplified analytical investigations of the perforated MAM (PMAM) indicate that the perforation introduces a second anti-resonance, where the effective surface mass density of the PMAM is much higher than the static value. The theoretical results are validated using impedance tube measurements, indicating good agreement between the theoretical predictions and the measured data. The anti-resonances yield high low-frequency sound transmission loss values with peak values over 25 dB higher than the corresponding mass-law. - Highlights: • A new membrane-type acoustic metamaterial exhibiting negative density is presented. • The metamaterial design contains a ring mass with a perforation through the membrane. • The sound transmission loss exhibits narrow-band peaks much higher than the mass-law. • The emergence of the peaks is explained using a simple theoretical model. • Impedance tube measurements are used to validate the theoretical predictions.

  19. Oriented cluster perforating technology and its application in horizontal wells

    Directory of Open Access Journals (Sweden)

    Huabin Chen

    2016-11-01

    Full Text Available An oriented cluster perforating technology, which integrates both advantages of cluster and oriented perforating, will help solve a series of technical complexities in horizontal well drilling. For realizing its better application in oil and gas development, a series of technologies were developed including perforator self-weight eccentricity, matching of the electronic selective module codes with the surface program control, axial centralized contact signal transmission, and post-perforation intercluster sealing insulation. In this way, the following functions could be realized, such as cable-transmission horizontal well perforator self-weight orientation, dynamic signal transmission, reliable addressing & selective perforation and post-perforation intercluster sealing. The combined perforation and bridge plug or the multi-cluster perforation can be fulfilled in one trip of perforation string. As a result, the horizontal-well oriented cluster perforating technology based on cable conveying was developed. This technology was successfully applied in unconventional gas reservoir exploitation, such as shale gas and coalbed methane, with accurate orientation, reliable selective perforation and satisfactory inter-cluster sealing. The horizontal-well oriented cluster perforating technology benefits the orientation of horizontal well drilling with a definite target and direction, which provides a powerful support for the subsequent reservoir stimulation. It also promotes the fracturing fluid to sweep the principal pay zones to the maximum extent. Moreover, it is conductive to the formation of complex fracture networks in the reservoirs, making quality and efficient development of unconventional gas reservoirs possible.

  20. The value of CT in detecting pathologic bowel perforation

    International Nuclear Information System (INIS)

    Chang, Jong Wun; Shin, Joo Yong; Kim, Hong; Rhee, Chang Soo; Lee, Sung Moon; Joo, Yang Goo; Suh, Soo Jhi

    1997-01-01

    To evaluate the usefulness of CT for assessing the location and cause of pathologic gastrointestinal perforation. A retrospective analysis of abdominal CT was performed in 27 perforations of 26 patients with underlying gastrointestinal pathology. Fifteen benign and 12 malignant perforations consisted of five gastric cancers, one gastric ulcer, ten duodenal bulb ulcers. two bowel adhesions, one jejunal metastasis from lung cancer, one ileocolic Crohn's disease, one radiation colitis and six colon cancers. CT scans were evaluated for 1) diagnosis of bowel perforation, 2) assessment of the cause and site of perforation, and, in particular, differentiation between benignancy and malignancy, and 3) complications and their extent. CT easily detected varying amounts of free air or fluid collection, and infiltration or abscess formation adjacent to the main lesion, and the diagnosis of gastrointestinal perforation was therefore easy. In 11 of the 12 malignancies (92%), primary tumor was diagnosed, but detection of the site of perforation was possible in only seven cases(7/12, 58%). The 15 benign lesions revealed nonspecific CT findings, and the perforation site could be presumed in six (6/15, 40%). In one case of Crohn's disease, the primary cause was visualized. Among six colonic cancers, four pericolic abscesses and two fistulas to adjacent organs were found, but there was no evidence of diffuse peritonitis. CT was helpful to lead to optimal treatment of pathologic gastrointestinal On CT the detectability of perforation, primary benign or malignant lesion, perforation site and extent of complication was high, and this modality was therefore a useful indicator of the optimal treatment for pathologic gastrointestinal perforations.=20

  1. Duodenal perforation during percutaneous nephrolithotomy (PCNL ...

    African Journals Online (AJOL)

    A. Bansal

    2016-06-03

    Jun 3, 2016 ... Calculus;. Duodenum;. Injury;. Paediatric;. Percutaneous nephrolithotomy. Abstract. Introduction: Colonic perforations are known complications of percutaneous nephrolithotomy (PCNL). However, to the best of our knowledge, small bowel perforation has rarely been reported.. Observation: We report the ...

  2. External perforated window Solar Screens: The effect of screen depth and perforation ratio on energy performance in extreme desert environments

    KAUST Repository

    Sherif, A.

    2012-09-01

    In hot arid desert environments, the solar radiation passing through windows increases the cooling loads and the energy consumption of buildings. Shading of windows can reduce these loads. Unlike the woven solar screens, wooden solar screens have a thickness that provides selective shading properties. Perforated wooden solar screens were traditionally used for windows shading. Developing modern types of these shading systems can lead to significant energy savings. The paper addresses the influence of changing the perforation percentage and depth of these screens on the annual energy loads, hence defining the optimum depth/perforation configurations for various window orientations. Series of experiments were performed using the EnergyPlus simulation software for a typical residential building in the Kharga Oasis, located in the Egyptian desert. A range of perforation percentages and depths were tested. Conclusions prove that external fixed deep perforated solar screens could effectively achieve energy savings up to 30% of the total energy consumption in the West and South orientations. Optimum range of depths and perforation percentages were recommended. These are: 80-90% perforation rate and 1:1 depth/opening width ratio. These lighter and deeper solar screen configurations were found to be more efficient in energy consumption in comparison with the traditional ones. © 2012 Elsevier B.V. All rights reserved.

  3. Intestinal perforation by an ingested foreign body*

    Science.gov (United States)

    Nicolodi, Gabriel Cleve; Trippia, Cesar Rodrigo; Caboclo, Maria Fernanda F. S.; de Castro, Francisco Gomes; Miller, Wagner Peitl; de Lima, Raphael Rodrigues; Tazima, Leandro; Geraldo, Jamylle

    2016-01-01

    Objective To identify the computed tomography findings suggestive of intestinal perforation by an ingested foreign body. Materials and Methods This was a retrospective study of four cases of surgically proven intestinal perforation by a foreign body, comparing the computed tomography findings with those described in the literature. Results None of the patients reported having ingested a foreign body, all were over 60 years of age, three of the four patients used a dental prosthesis, and all of the foreign bodies were elongated and sharp. In all four patients, there were findings indicative of acute abdomen. None of the foreign bodies were identified on conventional X-rays. The computed tomography findings suggestive of perforation were thickening of the intestinal walls (in all four cases), increased density of mesenteric fat (in all four cases), identification of the foreign body passing through the intestinal wall (in three cases), and gas in the peritoneal cavity (in one case). Conclusion In cases of foreign body ingestion, intestinal perforation is more common when the foreign body is elongated and sharp. Although patients typically do not report having ingested such foreign bodies, the scenario should be suspected in elderly individuals who use dental prostheses. A computed tomography scan can detect foreign bodies, locate perforations, and guide treatment. The findings that suggest perforation are thickening of the intestinal walls, increased mesenteric fat density, and, less frequently, gas in the peritoneal cavity, often restricted to the point of perforation. PMID:27818542

  4. Intestinal perforation by an ingested foreign body

    International Nuclear Information System (INIS)

    Nicolodi, Gabriel Cleve; Trippia, Cesar Rodrigo; Caboclo, Maria Fernanda F.S.; Castro, Francisco Gomes de; Miller, Wagner Peitl; Lima, Raphael Rodrigues de; Tazima, Leandro; Geraldo, Jamylle

    2016-01-01

    Objective: To identify the computed tomography findings suggestive of intestinal perforation by an ingested foreign body. Materials and Methods: This was a retrospective study of four cases of surgically proven intestinal perforation by a foreign body, comparing the computed tomography findings with those described in the literature. Results: None of the patients reported having ingested a foreign body, all were over 60 years of age, three of the four patients used a dental prosthesis, and all of the foreign bodies were elongated and sharp. In all four patients, there were findings indicative of acute abdomen. None of the foreign bodies were identified on conventional X-rays. The computed tomography findings suggestive of perforation were thickening of the intestinal walls (in all four cases), increased density of mesenteric fat (in all four cases), identification of the foreign body passing through the intestinal wall (in three cases), and gas in the peritoneal cavity (in one case). Conclusion: In cases of foreign body ingestion, intestinal perforation is more common when the foreign body is elongated and sharp. Although patients typically do not report having ingested such foreign bodies, the scenario should be suspected in elderly individuals who use dental prostheses. A computed tomography scan can detect foreign bodies, locate perforations, and guide treatment. The findings that suggest perforation are thickening of the intestinal walls, increased mesenteric fat density, and, less frequently, gas in the peritoneal cavity, often restricted to the point of perforation. (author)

  5. Intestinal perforation by an ingested foreign body.

    Science.gov (United States)

    Nicolodi, Gabriel Cleve; Trippia, Cesar Rodrigo; Caboclo, Maria Fernanda F S; de Castro, Francisco Gomes; Miller, Wagner Peitl; de Lima, Raphael Rodrigues; Tazima, Leandro; Geraldo, Jamylle

    2016-01-01

    To identify the computed tomography findings suggestive of intestinal perforation by an ingested foreign body. This was a retrospective study of four cases of surgically proven intestinal perforation by a foreign body, comparing the computed tomography findings with those described in the literature. None of the patients reported having ingested a foreign body, all were over 60 years of age, three of the four patients used a dental prosthesis, and all of the foreign bodies were elongated and sharp. In all four patients, there were findings indicative of acute abdomen. None of the foreign bodies were identified on conventional X-rays. The computed tomography findings suggestive of perforation were thickening of the intestinal walls (in all four cases), increased density of mesenteric fat (in all four cases), identification of the foreign body passing through the intestinal wall (in three cases), and gas in the peritoneal cavity (in one case). In cases of foreign body ingestion, intestinal perforation is more common when the foreign body is elongated and sharp. Although patients typically do not report having ingested such foreign bodies, the scenario should be suspected in elderly individuals who use dental prostheses. A computed tomography scan can detect foreign bodies, locate perforations, and guide treatment. The findings that suggest perforation are thickening of the intestinal walls, increased mesenteric fat density, and, less frequently, gas in the peritoneal cavity, often restricted to the point of perforation.

  6. Intestinal perforation by an ingested foreign body

    Energy Technology Data Exchange (ETDEWEB)

    Nicolodi, Gabriel Cleve; Trippia, Cesar Rodrigo; Caboclo, Maria Fernanda F.S.; Castro, Francisco Gomes de; Miller, Wagner Peitl; Lima, Raphael Rodrigues de; Tazima, Leandro; Geraldo, Jamylle, E-mail: gabrielnicolodi@gmail.com [Hospital Sao Vicente - Funef, Curitiba, PR (Brazil)

    2016-09-15

    Objective: To identify the computed tomography findings suggestive of intestinal perforation by an ingested foreign body. Materials and Methods: This was a retrospective study of four cases of surgically proven intestinal perforation by a foreign body, comparing the computed tomography findings with those described in the literature. Results: None of the patients reported having ingested a foreign body, all were over 60 years of age, three of the four patients used a dental prosthesis, and all of the foreign bodies were elongated and sharp. In all four patients, there were findings indicative of acute abdomen. None of the foreign bodies were identified on conventional X-rays. The computed tomography findings suggestive of perforation were thickening of the intestinal walls (in all four cases), increased density of mesenteric fat (in all four cases), identification of the foreign body passing through the intestinal wall (in three cases), and gas in the peritoneal cavity (in one case). Conclusion: In cases of foreign body ingestion, intestinal perforation is more common when the foreign body is elongated and sharp. Although patients typically do not report having ingested such foreign bodies, the scenario should be suspected in elderly individuals who use dental prostheses. A computed tomography scan can detect foreign bodies, locate perforations, and guide treatment. The findings that suggest perforation are thickening of the intestinal walls, increased mesenteric fat density, and, less frequently, gas in the peritoneal cavity, often restricted to the point of perforation. (author)

  7. Intestinal perforation by an ingested foreign body

    Directory of Open Access Journals (Sweden)

    Gabriel Cleve Nicolodi

    Full Text Available Abstract Objective: To identify the computed tomography findings suggestive of intestinal perforation by an ingested foreign body. Materials and Methods: This was a retrospective study of four cases of surgically proven intestinal perforation by a foreign body, comparing the computed tomography findings with those described in the literature. Results: None of the patients reported having ingested a foreign body, all were over 60 years of age, three of the four patients used a dental prosthesis, and all of the foreign bodies were elongated and sharp. In all four patients, there were findings indicative of acute abdomen. None of the foreign bodies were identified on conventional X-rays. The computed tomography findings suggestive of perforation were thickening of the intestinal walls (in all four cases, increased density of mesenteric fat (in all four cases, identification of the foreign body passing through the intestinal wall (in three cases, and gas in the peritoneal cavity (in one case. Conclusion: In cases of foreign body ingestion, intestinal perforation is more common when the foreign body is elongated and sharp. Although patients typically do not report having ingested such foreign bodies, the scenario should be suspected in elderly individuals who use dental prostheses. A computed tomography scan can detect foreign bodies, locate perforations, and guide treatment. The findings that suggest perforation are thickening of the intestinal walls, increased mesenteric fat density, and, less frequently, gas in the peritoneal cavity, often restricted to the point of perforation.

  8. Neurodevelopmental outcome after neonatal perforator stroke

    NARCIS (Netherlands)

    Ecury-Goossen, Ginette M; van der Haer, Marit; Smit, Liesbeth S; Feijen-Roon, Monique; Lequin, Maarten; de Jonge, Rogier C J; Govaert, Paul; Dudink, Jeroen

    AIM: To assess outcome after neonatal perforator stroke in the largest cohort to date. METHOD: Survivors from a cohort of children diagnosed with neonatal perforator stroke using cranial ultrasound or magnetic resonance imaging were eligible for inclusion. Recovery and Recurrence Questionnaire

  9. Duodenal perforation: an unusual complication of sickle cell anemia.

    Science.gov (United States)

    Acıpayam, Can; Aldıç, Güliz; Akçora, Bülent; Çelikkaya, Mehmet Emin; Aşkar, Hasan; Dorum, Bayram Ali

    2014-01-01

    Duodenal perforation in childhood is a rare condition with a high mortality rate if not treated surgically. Primary gastroduodenal perforation is frequently associated with peptic ulcer and exhibits a positive family history. Helicobacter pylorus is the most significant agent. Secondary gastroduodenal perforation may be a finding of specific diseases, such as Crohn disease, or more rarely may be associated with diseases such as cystic fibrosis or sickle cell anemia. A 14-year-old boy presented with abdominal and back pain. The patient was operated on for acute abdomen and diagnosed with duodenal perforation. Helicobacter pylorus was negative. There was no risk factor to account for duodenal perforation other than sickle cell anemia. Surgical intervention was successful and without significant sequelae. Duodenal perforation is a rare entity described in patients with sickle cell anemia. To our knowledge, this is the first report of duodenal perforation in a patient sickle cell anemia.

  10. The value of CT in detecting pathologic bowel perforation

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Jong Wun; Shin, Joo Yong; Kim, Hong; Rhee, Chang Soo; Lee, Sung Moon; Joo, Yang Goo; Suh, Soo Jhi [Keimyung Univ. School of Medicine, Taegu (Korea, Republic of)

    1997-10-01

    To evaluate the usefulness of CT for assessing the location and cause of pathologic gastrointestinal perforation. A retrospective analysis of abdominal CT was performed in 27 perforations of 26 patients with underlying gastrointestinal pathology. Fifteen benign and 12 malignant perforations consisted of five gastric cancers, one gastric ulcer, ten duodenal bulb ulcers. two bowel adhesions, one jejunal metastasis from lung cancer, one ileocolic Crohn's disease, one radiation colitis and six colon cancers. CT scans were evaluated for (1) diagnosis of bowel perforation, (2) assessment of the cause and site of perforation, and, in particular, differentiation between benignancy and malignancy, and (3) complications and their extent. CT easily detected varying amounts of free air or fluid collection, and infiltration or abscess formation adjacent to the main lesion, and the diagnosis of gastrointestinal perforation was therefore easy. In 11 of the 12 malignancies (92%), primary tumor was diagnosed, but detection of the site of perforation was possible in only seven cases(7/12, 58%). The 15 benign lesions revealed nonspecific CT findings, and the perforation site could be presumed in six (6/15, 40%). In one case of Crohn's disease, the primary cause was visualized. Among six colonic cancers, four pericolic abscesses and two fistulas to adjacent organs were found, but there was no evidence of diffuse peritonitis. CT was helpful to lead to optimal treatment of pathologic gastrointestinal On CT the detectability of perforation, primary benign or malignant lesion, perforation site and extent of complication was high, and this modality was therefore a useful indicator of the optimal treatment for pathologic gastrointestinal perforations.=20.

  11. Laparoscopic treatment of perforated appendicitis

    Science.gov (United States)

    Lin, Heng-Fu; Lai, Hong-Shiee; Lai, I-Rue

    2014-01-01

    The use of laparoscopy has been established in improving perioperative and postoperative outcomes for patients with simple appendicitis. Laparoscopic appendectomy is associated with less wound pain, less wound infection, a shorter hospital stay, and faster overall recovery when compared to the open appendectomy for uncomplicated cases. In the past two decades, the use of laparoscopy for the treatment of perforated appendicitis to take the advantages of minimally invasiveness has increased. This article reviewed the prevalence, approaches, safety disclaimers, perioperative and postoperative outcomes of the laparoscopic appendectomy in the treatment of patients with perforated appendicitis. Special issues including the conversion, interval appendectomy, laparoscopic approach for elderly or obese patient are also discussed to define the role of laparoscopic treatment for patients with perforated appendicitis. PMID:25339821

  12. DETERMINATION OF THE TEMPERATURE DISTRIBUTION THE PERFORATED FINS UNDER

    Directory of Open Access Journals (Sweden)

    Aziz7 M. Mhamuad

    2015-02-01

    Full Text Available This work treats the problem of heat transfer for perforated fins under natural convection. The temperature distribution is examined for an array of rectangular fins (15 fins with uniform cross-sectional area (100x270 mm embedded with various vertical body perforations that extend through the fin thickness. The patterns of perforations include 18 circular perforations (holes. Experiments were carried out in an experimental facility that was specifically design and constructed for this purpose. The heat transfer rate and the coefficient of heat transfer increases with perforation diameter increased. 

  13. Perforated peptic ulcer: How to improve outcome?

    DEFF Research Database (Denmark)

    Møller, Morten Hylander; Adamsen, Sven; Wøjdemann, Morten

    2008-01-01

    Despite the introduction of histamine H(2)-receptor antagonists, proton-pump inhibitors and the discovery of Helicobacter pylori, both the incidence of emergency surgery for perforated peptic ulcer and the mortality rate for patients undergoing surgery for peptic ulcer perforation have increased...... with an emphasis on risks that are preventable. A systematic review including randomized studies was carried out. There are a limited number of studies of patients with peptic ulcer perforation. Most of these studies are of low evidential status. Only a few randomized, controlled trials have been published...... to improve the outcome of patients with peptic ulcer perforation, sepsis needs to be factored into the existing knowledge and treatment Udgivelsesdato: 2008/8/27...

  14. Fast track pathway for perforated appendicitis.

    Science.gov (United States)

    Frazee, Richard; Abernathy, Stephen; Davis, Matthew; Isbell, Travis; Regner, Justin; Smith, Randall

    2017-04-01

    Perforated appendicitis is associated with an increased morbidity and length of stay. "Fast track" protocols have demonstrated success in shortening hospitalization without increasing morbidity for a variety of surgical processes. This study evaluates a fast track pathway for perforated appendicitis. In 2013, a treatment pathway for perforated appendicitis was adopted by the Acute Care Surgery Service for patients having surgical management of perforated appendicitis. Interval appendectomy was excluded. Patients were treated initially with intravenous antibiotics and transitioned to oral antibiotics and dismissed when medically stable and tolerating oral intake. A retrospective review of patients managed on the fast track pathway was undertaken to analyze length of stay, morbidity, and readmissions. Thirty-four males and twenty-one females with an average age of 46.8 years underwent laparoscopic appendectomy for perforated appendicitis between January 2013 and December 2014. Pre-existing comorbidities included hypertension 42%, diabetes mellitus 11%, COPD 5% and heart disease 2%. No patient had conversion to open appendectomy. Average length of stay was 2.67 days and ranged from 1 to 12 days (median 2 days). Postoperative morbidity was 20% and included abscess (6 patients), prolonged ileus (3 patients), pneumonia (1 patient), and congestive heart failure (1 patient). Five patients were readmitted for abscess (3 patients), congestive heart failure (1 patient), and pneumonia (1 patient). A fast track pathway for perforated appendicitis produced shorter length of stay and acceptable postoperative morbidity and readmission. This offers the potential for significant cost savings over current national practice patterns. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. The Heidelberg Appendicitis Score Predicts Perforated Appendicitis in Children.

    Science.gov (United States)

    Boettcher, Michael; Günther, Patrick; Breil, Thomas

    2017-10-01

    In the future, surgical management of pediatric appendicitis might become limited to nonperforating appendicitis. Thus, it becomes increasingly important to differentiate advanced from simple appendicitis and to predict perforated appendicitis among a group of children with right-sided abdominal pain, which was the aim of this study. An institutionally approved, single-center retrospective analysis of all patients with appendectomy from January 2009 to December 2010 was conducted. All diagnostic aspects were evaluated to identify predictors and differentiators of perforated appendicitis. In 2 years, 157 children suffered from appendicitis. Perforation occurred in 47 (29.9%) of the patients. C-reactive protein (CRP) levels higher than 20 mg/dL ( P = .037) and free abdominal fluid on ultrasonography ( P = .031) are the most important features to differentiate perforated from simple appendicitis. Moreover, all children with perforation had a positive Heidelberg Appendicitis Score (HAS). A negative HAS excludes perforation in all cases (negative predictive value = 100%). Perforated appendicitis can be ruled out by the HAS. In a cohort with right-sided abdominal pain, perforation should be considered in children with high CRP levels and free fluids or abscess formation on ultrasound.

  16. Medicolegal aspects of iatrogenic root perforations

    DEFF Research Database (Denmark)

    Tsesis, I; Rosen, E; Bjørndal, L

    2014-01-01

    AIM: To retrospectively analyze the medico-legal aspects of iatrogenic root perforations (IRP) that occurred during endodontic treatments. METHODOLOGY: A comprehensive search in a professional liability insurance database was conducted to retrospectively identify cases of IRP following root canal...... treatment (p root perforation is a complication of root canal treatment and may result in tooth extraction...... and in legal actions against the treating practitioner. Mandibular molars are more prone to medico-legal claims related to root perforations. The patient should be informed of the risks during RCT and should get information on alternative treatments and their risks and prognosis...

  17. Spontaneous ileal perforation complicating low anorectal malformation

    Directory of Open Access Journals (Sweden)

    TiJesuni Olatunji

    2015-01-01

    Full Text Available Anorectal malformation is a common anomaly in neonates. Although colorectal perforations have been reported as a complication, ileal perforation is rarely encountered. This is a report of a 2-day-old boy presenting with a low anorectal malformation, complicated with ileal perforation, necessitating laparotomy and ileal repair. Anoplasty was done for the low anomaly. Early presentation and prompt treatment of anorectal malformations is important to prevent such potential life threatening complication.

  18. Premixed Combustion of Coconut Oil on Perforated Burner

    Directory of Open Access Journals (Sweden)

    I.K.G. Wirawan

    2013-10-01

    Full Text Available Coconut oil premixed combustion behavior has been studied experimentally on perforated burner with equivalence ratio (φ varied from very lean until very rich. The results showed that burning of glycerol needs large number of air so that the laminar burning velocity (SL is the highest at very lean mixture and the flame is in the form of individual Bunsen flame on each of the perforated plate hole. As φ is increased the  SL decreases and the secondary Bunsen flame with open tip occurs from φ =0.54 at the downstream of perforated flame. The perforated flame disappears at φ = 0.66 while the secondary Bunsen flame still exist with SL increases following that of hexadecane flame trend and then extinct when the equivalence ratio reaches one or more. Surrounding ambient air intervention makes SL decreases, shifts lower flammability limit into richer mixture, and performs triple and cellular flames. The glycerol diffusion flame radiation burned fatty acids that perform cellular islands on perforated hole.  Without glycerol, laminar flame velocity becomes higher and more stable as perforated flame at higher φ. At rich mixture the Bunsen flame becomes unstable and performs petal cellular around the cone flame front. Keywords: cellular flame; glycerol; perforated flame;secondary Bunsen flame with open tip; triple flame

  19. Microvascular anatomy of the cerebellar parafloccular perforating space.

    Science.gov (United States)

    Sosa, Pablo; Dujovny, Manuel; Onyekachi, Ibe; Sockwell, Noressia; Cremaschi, Fabián; Savastano, Luis E

    2016-02-01

    The cerebellopontine angle is a common site for tumor growth and vascular pathologies requiring surgical manipulations that jeopardize cranial nerve integrity and cerebellar and brainstem perfusion. To date, a detailed study of vessels perforating the cisternal surface of the middle cerebellar peduncle-namely, the paraflocculus or parafloccular perforating space-has yet to be published. In this report, the perforating vessels of the anterior inferior cerebellar artery (AICA) in the parafloccular space, or on the cisternal surface of the middle cerebellar peduncle, are described to elucidate their relevance pertaining to microsurgery and the different pathologies that occur at the cerebellopontine angle. Fourteen cadaveric cerebellopontine cisterns (CPCs) were studied. Anatomical dissections and analysis of the perforating arteries of the AICA and posterior inferior cerebellar artery at the parafloccular space were recorded using direct visualization by surgical microscope, optical histology, and scanning electron microscope. A comprehensive review of the English-language and Spanish-language literature was also performed, and findings related to anatomy, histology, physiology, neurology, neuroradiology, microsurgery, and endovascular surgery pertaining to the cerebellar flocculus or parafloccular spaces are summarized. A total of 298 perforating arteries were found in the dissected specimens, with a minimum of 15 to a maximum of 26 vessels per parafloccular perforating space. The average outer diameter of the cisternal portion of the perforating arteries was 0.11 ± 0.042 mm (mean ± SD) and the average length was 2.84 ± 1.2 mm. Detailed schematics and the surgical anatomy of the perforating vessels at the CPC and their clinical relevance are reported. The parafloccular space is a key entry point for many perforating vessels toward the middle cerebellar peduncle and lateral brainstem, and it must be respected and protected during surgical approaches to the

  20. Simulation and Performance Test Technology Development for Semiconductor Radiation Detection Instrument Fabrication

    International Nuclear Information System (INIS)

    Kim, Jong Kyung; Lee, W. G.; Kim, S. Y.; Shin, C. H.; Kim, K. O.; Park, J. M.; Jang, D. Y.; Kang, J. S.

    2010-06-01

    - Analysis on the Absorbed Dose and Electron Generation by Using MCNPX Code - Analysis on the Change of Measured Energy Spectrum As a Function of Bias Voltage Applied in Semiconductor Detector - Comparison of Monte Carlo Simulation Considering the Charge Collection Efficiency and Experimental Result - Development of Semiconductor Sensor Design Code Based on the Graphic User Interface - Analysis on Depth Profile of Ion-implanted Semiconductor Wafer Surface and Naturally Generated SiO2 Insulation Layer Using Auger Electron Spectroscopy - Measurement of AFM Images and Roughness to Abalyze Surface of Semiconductor Wafer with respect to Annealing and Cleaning Process - Measurement of Physical Properties for Semiconductor Detector Surface after CZT Passivation Process - Evaluation of Crystal Structure and Specific Resistance of CZT - Measurement/Analysis on Band Structure of CZT Crystal - Evaluation of Neutron Convertor Layer with respect to Change in Temperature - Measurement/Evaluation of physical characteristics for lattice parameter, specific resistance, and band structure of CZT crystal - Measurement/Evaluation of lattice transition of SiC semiconductor detector after radiation irradiation - Measurement/Evaluation of performance of semiconductor detector with respect to exposure in high temperature environment

  1. A Novel Perforator Flap Training Model Using a Chicken Leg.

    Science.gov (United States)

    Cifuentes, Ignacio J; Yañez, Ricardo A; Salisbury, Maria C; Rodriguez, José R; Varas, Julian E; Dagnino, Bruno L

    2016-04-01

    Living animal models are frequently used for perforator flap dissection training, but no ex vivo models have been described. The aim of this study is to present a novel nonliving model for perforator flap training based on a constant perforator in the chicken leg. A total of 15 chicken legs were used in this study. Anatomical dissection of the perforator was performed after its identification using ink injection, and in four of these specimens a perforator-based flap was raised. The anatomical dissection revealed a constant intramuscular perforator with a median length of 5.7 cm. Median proximal and distal vessel diameters were 0.93 and 0.4 mm, respectively. The median dissection time was 77.5 minutes. This study introduces a novel, affordable, and reproducible model for the intramuscular dissection of a perforator-based flap using an ex vivo animal model. Its consistent perforator and appropriate-sized vessels make it useful for training.

  2. Esophageal perforation

    Science.gov (United States)

    ... esophagus into the space around the lungs. Collapsed lung. X-rays taken after you drink a non-harmful dye can help pinpoint the location of the perforation. You may also have chest CT scan look for an abscess in the chest or esophageal cancer.

  3. [Iatrogen perforation of the rectum after colon radiography].

    Science.gov (United States)

    Eggum, R; Kressner, U; Haffner, J

    1998-05-10

    Perforation of the rectum following barium enema is relatively rare, occurring in 1 of 3,000 procedures. Colorectal perforation is a serious condition and early diagnosis is of paramount importance in order to avoid any delay in treating the patient. Direct suture of the perforation, lavage, presacral drainage and stomia are the preferred methods of primary surgical treatment.

  4. Monitoring of the Irradiated Neutron Fluence in the Neutron Transmutation Doping Process of Hanaro

    Science.gov (United States)

    Kim, Myong-Seop; Park, Sang-Jun

    2009-08-01

    Neutron transmutation doping (NTD) for silicon is a process of the creation of phosphorus impurities in intrinsic or extrinsic silicon by neutron irradiation to obtain silicon semiconductors with extremely uniform dopant distribution. HANARO has two vertical holes for the NTD, and the irradiation for 5 and 6 inch silicon ingots has been going on at one hole. In order to achieve the accurate neutron fluence corresponding to the target resistivity, the real time neutron flux is monitored by self-powered neutron detectors. After irradiation, the total irradiation fluence is confirmed by measuring the absolute activity of activation detectors. In this work, a neutron fluence monitoring method using zirconium foils with the mass of 10 ~ 50 mg was applied to the NTD process of HANARO. We determined the proportional constant of the relationship between the resistivity of the irradiated silicon and the neutron fluence determined by using zirconium foils. The determined constant for the initially n-type silicon was 3.126 × 1019 n·Ω/cm. It was confirmed that the difference between this empirical value and the theoretical one was only 0.5%. Conclusively, the practical methodology to perform the neutron transmutation doping of silicon was established.

  5. Neutron spectrometry by diamond detector for nuclear radiation

    International Nuclear Information System (INIS)

    Kozlov, S.F.; Konorova, E.A.; Barinov, A.L.; Jarkov, V.P.

    1975-01-01

    Experiments on fast neutron spectrometry using the nuclear radiation diamond detector inside a horizontal channel of a water-cooled and water-moderated reactor are described. It is shown that the diamond detector enables neutron spectra to be measured within the energy range of 0.3 to 10 MeV against reactor gamma-radiation background and has radiation resistance higher than that of conventional semiconductor detectors. (U.S.)

  6. Perforated duodenal ulcer: an unusual complication of gastroenteritis.

    OpenAIRE

    Wilson, J M; Darby, C R

    1990-01-01

    A 7 year old boy was admitted to hospital with gastroenteritis, which was complicated by an acute perforated duodenal ulcer. After oversewing of the perforation he made an uncomplicated recovery. Peptic ulceration is under-diagnosed in childhood and this leads to delay in diagnosis and appropriate management. Ulceration is associated with severe illness and viral infections, but perforation is rare.

  7. Iatrogen perforation of the rectum following barium enema

    International Nuclear Information System (INIS)

    Eggum, R.; Kressner, U.; Haffner, J.

    1998-01-01

    Perforation of the rectum following barium enema is relatively rare, occurring in 1 of 3,000 procedures. Colorectal perforation is a serious condition and early diagnosis is of paramount importance in order to avoid any delay in treating the patient. Direct suture of the perforation, lavage, presacral drainage and stomia are the preferred methods of primary surgical treatment. 10 refs., 1 fig

  8. Test and evaluation of semiconductor components in mixed field radiation monitoring

    International Nuclear Information System (INIS)

    Cardenas, Jose Patricio N.; Madi Filho, Tufic; Rodrigues, Leticia L.C.

    2009-01-01

    Silicon components have found extensive use in nuclear spectroscopy and counting, as described in many articles in the last three decades. These devices have found utility in radiation dosimetry because a diode, for instance, produces a current approximately 18000 times higher than any ionization chamber of equal sensitive volume. This reduces stringent requirements from the electronics used to amplify or integrate the current and / or allows approaching the ideal detector point for the mapping of radiation fields. For better performance, in the case of diodes, they are normally used with high inverse polarity to obtain a deeper barrier, less noise and shorter transit time. The aim of this work was the evaluation of these semiconductor components for application in ionizing radiation fields monitoring, in nuclear research reactors and radiotherapy facilities, for radiation protection and health physics purposes. Experimental configurations to analyze the performance of commercial semiconductors, such as silicon PIN Photodiodes and Silicon Surface Barrier Detectors, were developed and the performance of three different configurations of charge preamplifier with silicon components was also studied. Components were evaluated for application as neutron detectors, using some types of radiators (converters). The radiation response of these silicon components to neutron fields from nuclear research reactors IEA-R1 and IPEN-MB1 (thermal, epithermal and fast neutrons), from beam holes, experimental halls and AmBe neutron sources in laboratory was investigated. (author)

  9. Parasacral Perforator Flaps for Reconstruction of Sacral Pressure Sores.

    Science.gov (United States)

    Lin, Chin-Ta; Chen, Shih-Yi; Chen, Shyi-Gen; Tzeng, Yuan-Sheng; Chang, Shun-Cheng

    2015-07-01

    Despite advances in reconstruction techniques, pressure sores continue to present a challenge to the plastic surgeon. The parasacral perforator flap is a reliable flap that preserves the entire contralateral side as a future donor site. On the ipsilateral side, the gluteal muscle itself is preserved and all flaps based on the inferior gluteal artery are still possible. We present our experience of using parasacral perforator flaps in reconstructing sacral defects. Between August 2004 and January 2013, 19 patients with sacral defects were included in this study. All the patients had undergone surgical reconstruction of sacral defects with a parasacral perforator flap. The patients' sex, age, cause of sacral defect, flap size, flap type, numbers of perforators used, rotation angle, postoperative complications, and hospital stay were recorded. There were 19 parasacral perforator flaps in this series. All flaps survived uneventfully except for 1 parasacral perforator flap, which failed because of methicillin-resistant Staphylococcus aureus infection. The overall flap survival rate was 95% (18/19). The mean follow-up period was 17.3 months (range, 2-24 months). The average length of hospital stay was 20.7 days (range, 9-48 days). No flap surgery-related mortality was found. Also, there was no recurrence of sacral pressure sores or infected pilonidal cysts during the follow-up period. Perforator-based flaps have become popular in modern reconstructive surgery because of low donor-site morbidity and good preservation of muscle. Parasacral perforator flaps are durable and reliable in reconstructing sacral defects. We recommend the parasacral perforator flap as a good choice for reconstructing sacral defects.

  10. Acquired perforating dermatosis in a patient with chronic renal failure.

    Science.gov (United States)

    Fernandes, Karen de Almeida Pinto; Lima, Lourenço de Azevedo; Guedes, Juliana Chaves Ruiz; Lima, Ricardo Barbosa; D'Acri, Antônio Macedo; Martins, Carlos José

    2016-01-01

    Perforating dermatoses are a group of skin diseases characterized by transepidermal elimination of dermal material. The disease is divided into two groups: the primary group and the secondary group. The classical or primary perforating dermatoses are subdivided into four types according to the eliminated dermal materials: Kyrle disease, perforating reactive collagenosis, elastosis perforans serpiginosa, and perforating folliculitis. The secondary form is known as acquired perforating dermatosis. The term was proposed in 1989 by Rapini to designate the perforating dermatoses affecting adult patients with systemic disease, regardless of the dermal materials eliminated. This report describes a case of the disease with elimination of collagen and elastic fibers in a patient with chronic renal failure.

  11. Idiopathic gastric perforation in an asplenic infant | Olsen | African ...

    African Journals Online (AJOL)

    Introduction: The cause of idiopathic gastric perforations in neonates remains unknown. Perforations of the abdominal oesophagus, stomach and duodenum in infants and children are the rarest type of intestinal perforations. There are 21 reported cases of an idiopathic gastric rupture in nonneonates. Case Report: A ...

  12. Next Generation Neutron Scintillators Based On Semiconductor Nanostructures

    International Nuclear Information System (INIS)

    Wang, Cai-Lin

    2008-01-01

    The results reported here successfully demonstrate the technical feasibility of ZnS QDs/ 6 LiF/polymer composites as thermal neutron scintillators. PartTec has obtained stable ZnS QDs with a quantum yield of 17% induced by UV light, and light pulse decay lifetimes of 10-30 ns induced by both UV and neutrons. These lifetime values are much shorter than those of commercial ZnS microparticle and 6 Li-glass scintillators. Clear pulse height peaks induced by neutron irradiation were seen for PartTec's ZnS nanocomposites. By adjusting the concentrations, particle size and degree of dispersion of ZnS QD/ 6 LiF in a PVA matrix, the light absorption and light yield of films at 420-440 nm can be optimized. PartTec's novel scintillators will replace traditional 6 Li-glass and ZnS/ 6 LiF:Ag scintillators if the PL quantum yield can be improved above 30%, and/or increase the transparency of present nanoscintillators. Time and resources inhibited PartTec's total success in Phase I. For example, bulk doping preparations of ZnS QDs with Ag + , Eu 3+ or Ce 3+ QDs was impractical given those constraints, nor did they permit PartTec to measure systematically the change of PL decay lifetimes in different samples. PartTec will pursue these studies in the current proposal, as well as develop a better capping and dopant along with developing brighter and faster ZnS QD scintillators.

  13. CORRELATION BETWEEN TYMPANIC MEMBRANE PERFORATION AND HEARING LOSS

    Directory of Open Access Journals (Sweden)

    Lidija RISTOVSKA

    2016-04-01

    Full Text Available Introduction: Perforation of the tympanic membrane primarily results from middle ear infections, trauma or iatrogenic causes. The perforation causes conductive hearing loss by reducing the surface area available for sound transmission to the ossicular chain. Objective: The objective was to analyze the characteristics of tympanic membrane perforations in relation to hearing loss and to determine the type and degree of hearing loss. Materials and methods: We analyzed audiometric, otoscopic findings and medical reports of 218 patients, 114 males (52.3% and 104 females (47.7%, aged 9 to 75 years (mean age of 47.9 years, examined during the period of November 2012 to October 2015. For statistical data analysis we used Chi-square test with level of significance p<0.05. Results: Most of the patients had unilateral perforations (89% with right ear predominance and involvement of two quadrants of pars tensa (37.2%. Mean air-bone gap was 23.9 dB. The largest air-bone gap was at frequency of 250 Hz. Most of the patients (73.1% had mixed hearing loss (p=0.032, and average hearing thresholds from 21 to 40 dB. Conclusion: Mean air-bone gap is largest at the lower frequencies, and decreases as frequency increases. Size of the perforation has effect on hearing loss. Mean air-bone gap increases with increasing size of the perforation. There is no big difference between the mean air-bone gap in posterior versus anterior perforations.

  14. Gallbladder perforation complicating typhoid fever: report of two cases.

    Science.gov (United States)

    Gali, B M; Ali, N; Agbese, G O; Duna, V D; Dawha, S D; Ismai, G I; Mohammed, M

    2011-01-01

    Gallbladder perforation (GBP) is rare and as a complication of typhoid fever is extremely rare. We present two consecutive patients with GBP diagnosed incidentally at laparotomy. Information on the management of two patients with gallbladder perforation seen at Federal Medical Centre Azare in June and October 2008 was extracted from their case records. The two patients were both males aged 13 years and 16 years. They both presented with high fever of more than 2 weeks duration; and abdominal pain and distension. Both patients had features of generalised peritonitis. Pre-operative diagnoses of typhoid enteric perforation were made based on a positive Widal test. Intra-operative findings however, were that of bile peritonitis and gallbladder perforation. Both had cholecystectomy. Culture of the bile aspirate yielded Salmonella typhi. Gallbladder perforation secondary to typhoid fever should be considered as a differential diagnosis in patients with suspected typhoid enteric perforation in typhoid fever endemic region.

  15. Quantitative autoradiography of semiconductor base material

    International Nuclear Information System (INIS)

    Treutler, H.C.; Freyer, K.

    1983-01-01

    Autoradiographic methods for the quantitative determination of elements interesting in semiconductor technology and their distribution in silicon are described. Whereas the local concentration and distribution of phosphorus has been determined with the aid of silver halide films the neutron-induced autoradiography has been applied in the case of boron. Silicon disks containing diffused phosphorus or implanted or diffused boron have been used as standard samples. Different possibilities of the quantitative evaluation of autoradiograms are considered and compared

  16. The development of the market for neutron transmutation doped silicon

    International Nuclear Information System (INIS)

    Herzer, H.; Vieweg-Gutberlet, G.

    1984-01-01

    Neutron transmutation doped silicon was introduced to the electronic device market in the 1975-1976 time period. Today, neutron transmutation doping is definitely a mature technology applied mainly to semiconductor power devices. There is no doubt that the power device sector will remain the major consumer of NTD silicon in the near future. This paper examines the possible application of NTD silicon to other areas of the semiconductor market, and concludes that the need for NTD silicon will continue to grow and will expand into other applications. Consequently, unless new reactor capacities become available by the end of the decade, NTD silicon applications will probably be limited mainly to power and sensor devices

  17. Hyperbilirubinemia as a predictor for appendiceal perforation

    DEFF Research Database (Denmark)

    Burcharth, J; Pommergaard, H C; Rosenberg, J

    2013-01-01

    Delayed or wrong diagnosis in patients with appendicitis can result in perforation and consequently increased morbidity and mortality. Serum bilirubin may be a useful marker for appendiceal perforation. The purpose of this systematic review was to evaluate studies investigating elevated serum...

  18. Sigmoid Colonic Perforation with Faecal Peritonitis due to Faecaloma

    Directory of Open Access Journals (Sweden)

    Ibrahim Khalil

    2014-09-01

    Full Text Available Colon perforation is an uncommon event usually caused by malignancy, diverticular disease, amoebic colitis, steroid therapy, trauma and ulcerative colitis, but stercoral perforation is very rare. Severe chronic constipation is considered to be the main causative factor in development of stercoral perforation of colon. Sometimes it can also produce catastrophic complications like colonic obstruction, faecal peritonitis and septicaemia. We report a rare case of sigmoid colonic perforation with faecal peritonitis and pneumoperitonium due to faecaloma which was diagnosed after exploratory laparotomy.

  19. Peptic ulcer perforation

    African Journals Online (AJOL)

    FinePrint

    2015-06-01

    Jun 1, 2015 ... Peptic ulcer perforation is one of the surgical complications of peptic ulcer ... Treatment can be operative or non-operative followed by proton .... chronic gastritis without evidence of ... inhibits pancreatic bicarbonate secretion.

  20. Perforated peptic ulcer following gastric bypass for obesity.

    Science.gov (United States)

    Macgregor, A M; Pickens, N E; Thoburn, E K

    1999-03-01

    Peptic ulcer in the excluded segment of a gastric bypass performed in the management of morbid obesity has only rarely been reported in the literature. The purpose of this study is to review our experience with the condition in a series of 4300 patients who underwent gastric-restrictive surgery between 1978 and 1997. Eleven patients presented with acute perforation of a peptic ulcer in the excluded gastric segment. Nine ulcers were duodenal, one was gastric, and one patient had both gastric and duodenal perforations. The time between primary gastric-restrictive surgery and ulcer perforation varied from 20 days to 12 years. All patients presented with upper abdominal pain. The classical radiological sign of perforated peptic ulcer, free air under the diaphragm, did not occur in any patient. Nine patients were initially treated by primary closure of the perforation with subsequent definitive ulcer therapy by vagotomy, pyloroplasty, or gastrectomy. One case, initially treated elsewhere, was managed by placement of a Malecot catheter through the duodenal perforation, gastrostomy, and peritoneal drainage. One recent case remains symptom-free on H2 blockers after simple closure. There was no mortality. Six cases were previously reported in the literature with a 33 per cent mortality rate.

  1. Comparison between Silicon-Carbide and diamond for fast neutron detection at room temperature

    Directory of Open Access Journals (Sweden)

    Obraztsova O.

    2018-01-01

    Full Text Available Neutron radiation detector for nuclear reactor applications plays an important role in getting information about the actual neutron yield and reactor environment. Such detector must be able to operate at high temperature (up to 600° C and high neutron flux levels. It is worth nothing that a detector for industrial environment applications must have fast and stable response over considerable long period of use as well as high energy resolution. Silicon Carbide is one of the most attractive materials for neutron detection. Thanks to its outstanding properties, such as high displacement threshold energy (20-35 eV, wide band gap energy (3.27 eV and high thermal conductivity (4.9 W/cm·K, SiC can operate in harsh environment (high temperature, high pressure and high radiation level without additional cooling system. Our previous analyses reveal that SiC detectors, under irradiation and at elevated temperature, respond to neutrons showing consistent counting rates as function of external reverse bias voltages and radiation intensity. The counting-rate of the thermal neutron-induced peak increases with the area of the detector, and appears to be linear with respect to the reactor power. Diamond is another semi-conductor considered as one of most promising materials for radiation detection. Diamond possesses several advantages in comparison to other semiconductors such as a wider band gap (5.5 eV, higher threshold displacement energy (40-50 eV and thermal conductivity (22 W/cm·K, which leads to low leakage current values and make it more radiation resistant that its competitors. A comparison is proposed between these two semiconductors for the ability and efficiency to detect fast neutrons. For this purpose the deuterium-tritium neutron generator of Technical University of Dresden with 14 MeV neutron output of 1010 n·s-1 is used. In the present work, we interpret the first measurements and results with both 4H-SiC and chemical vapor deposition (CVD

  2. Comparison between Silicon-Carbide and diamond for fast neutron detection at room temperature

    Science.gov (United States)

    Obraztsova, O.; Ottaviani, L.; Klix, A.; Döring, T.; Palais, O.; Lyoussi, A.

    2018-01-01

    Neutron radiation detector for nuclear reactor applications plays an important role in getting information about the actual neutron yield and reactor environment. Such detector must be able to operate at high temperature (up to 600° C) and high neutron flux levels. It is worth nothing that a detector for industrial environment applications must have fast and stable response over considerable long period of use as well as high energy resolution. Silicon Carbide is one of the most attractive materials for neutron detection. Thanks to its outstanding properties, such as high displacement threshold energy (20-35 eV), wide band gap energy (3.27 eV) and high thermal conductivity (4.9 W/cm·K), SiC can operate in harsh environment (high temperature, high pressure and high radiation level) without additional cooling system. Our previous analyses reveal that SiC detectors, under irradiation and at elevated temperature, respond to neutrons showing consistent counting rates as function of external reverse bias voltages and radiation intensity. The counting-rate of the thermal neutron-induced peak increases with the area of the detector, and appears to be linear with respect to the reactor power. Diamond is another semi-conductor considered as one of most promising materials for radiation detection. Diamond possesses several advantages in comparison to other semiconductors such as a wider band gap (5.5 eV), higher threshold displacement energy (40-50 eV) and thermal conductivity (22 W/cm·K), which leads to low leakage current values and make it more radiation resistant that its competitors. A comparison is proposed between these two semiconductors for the ability and efficiency to detect fast neutrons. For this purpose the deuterium-tritium neutron generator of Technical University of Dresden with 14 MeV neutron output of 1010 n·s-1 is used. In the present work, we interpret the first measurements and results with both 4H-SiC and chemical vapor deposition (CVD) diamond

  3. Stercoral perforation in a 17-year old.

    LENUS (Irish Health Repository)

    McHugh, S

    2012-02-01

    INTRODUCTION: Stercoral perforation is a rare cause of perforation. This is the first reported case where a partial eating disorder (ED) is the primary causative differential. CASE PRESENTATION: We present the case of a 17-year-old girl who presented to her local Emergency Department with a 24-h history of left-sided abdominal pain. She subsequently deteriorated and a computed tomography scan of her abdomen showed gross distension of the large bowel with a sigmoid perforation. She underwent total colectomy with end ileostomy. Histology reported stercoral perforation but normal bowel ganglia. While an inpatient she was reviewed by the Psychiatric team who were concerned she was suffering from a partial ED. CONCLUSION: This case highlights the importance of a multidisciplinary approach in optimally treating patients such as these. Aggressive medical management with involvement of a psychiatric team and dietetics addresses any underlying causative psychiatric issues and helps prevent recurrence.

  4. Stercoral perforation in a 17-year old.

    LENUS (Irish Health Repository)

    McHugh, S

    2009-04-02

    INTRODUCTION: Stercoral perforation is a rare cause of perforation. This is the first reported case where a partial eating disorder (ED) is the primary causative differential. CASE PRESENTATION: We present the case of a 17-year-old girl who presented to her local Emergency Department with a 24-h history of left-sided abdominal pain. She subsequently deteriorated and a computed tomography scan of her abdomen showed gross distension of the large bowel with a sigmoid perforation. She underwent total colectomy with end ileostomy. Histology reported stercoral perforation but normal bowel ganglia. While an inpatient she was reviewed by the Psychiatric team who were concerned she was suffering from a partial ED. CONCLUSION: This case highlights the importance of a multidisciplinary approach in optimally treating patients such as these. Aggressive medical management with involvement of a psychiatric team and dietetics addresses any underlying causative psychiatric issues and helps prevent recurrence.

  5. Colonic carcinoma with multiple small bowel perforations mimicking intestinal obstruction

    Directory of Open Access Journals (Sweden)

    Khanna Rahul

    2006-09-01

    Full Text Available Abstract Background Carcinoma of the colon may present with perforation proximal to the site of malignancy. Caecum is the commonest site of perforation if the ileocecal valve is patent and the jejunal and ileal perforations are very rare. Case presentation A 35 year male presented with intestinal obstruction. Emergency laparotomy revealed carcinoma of the transverse colon with multiple pinpoint perforations along antimesenteric border of ileum, which were wrapped with omentum, and no peritoneal contamination was present. Extended right hemicolectomy with jejunocolic anastomosis was done. Patient made uneventful recovery in postoperative period and was treated with adjuvant chemotherapy. Conclusion Patients with colonic carcinoma and incompetent ileocecal valve may present with intestinal perforation. Increased intraluminal pressure and closed loop obstruction may lead to ischemia and perforation of the small bowel.

  6. Energy Analysis of Solar Collector With perforated Absorber Plate

    Directory of Open Access Journals (Sweden)

    Ammar A. Farhan

    2017-09-01

    Full Text Available The thermal performance of three solar collectors with 3, 6 mm and without perforation absorber plate was assessed experimentally. The experimental tests were implemented in Baghdad during the January and February 2017. Five values of airflow rates range between 0.01 – 0.1 m3/s were used through the test with a constant airflow rate during the test day. The variation of the following parameters air temperature difference, useful energy, absorber plate temperature, and collector efficiency was recorded every 15 minutes. The experimental data reports that the increases the number of absorber plate perforations with a small diameter is more efficient rather than increasing the hole diameter of the absorber plate with decreasing the perforation numbers. Maximum air temperature difference throughout the solar collector with 3, 6 mm perforations and without perforations are 17, 15, and 12 oC, respectively. Also, it can be concluded that the energy gained from the solar collector with 3 mm perforation absorber plate is 28.2 % more than the energy gained from solar collector without holes per day for 0.1 m3/s airflow rate. The maximum values of the thermal performance curves are 0.67, 0.64, and 0.56 for the solar collector with 3, 6 mm, and without perforations, respectively.

  7. Arrangement for formation perforating and fracturing

    Energy Technology Data Exchange (ETDEWEB)

    Belyaev, B M; Vitsenii, E M; Zheltov, Yu P; Nikolaev, S I

    1962-03-06

    An arrangement for perforating and hydraulic fracturing, to be lowered on a wire line, consists of a chamber with a shaped charge, a head and a nozzle. This arrangement enables carrying out, simultaneously, the operations of perforating and fracturing. The device may be equipped with separate sections with shaped charges and a powder chamber in which powder charges are placed, designed to be ignited in sequence by slow- acting electric igniters. For controlling the gas pressure and strengthening the arrangement in the zone of perforation, the device is equipped with rubber seals which release the ring elements under pressure of explosive gas. Between the walls of the casing and the rubber seals is an annular space through the gas escapes.

  8. Neutron moisture gaging of agricultural soil

    International Nuclear Information System (INIS)

    Pospisil, S.; Janout, Z.; Kovacik, M.

    1987-01-01

    The design is described of a neutron moisture gage which consists of a measuring probe, neutron detector, small electronic recording device and a 241 Am-Be radionuclide source. The neutron detector consists of a surface barrier semiconductor silicon detector and a conversion layer of lithium fluoride. The detection of triton which is the reaction product of lithium with neutrons by the silicon detector is manifested as a voltage pulse. The detector has low sensitivity for fast neutrons and for gamma radiation and is suitable for determining moisture values in large volume samples. Verification and calibration measurements were carried out of chernozem, brown soil and podzolic soils in four series. The results are tabulated. Errors of measurement range between 0.8 to 1.0%. The precision of measurement could be improved by the calibration of the device for any type of soil. (E.S.). 4 tabs., 6 refs., 5 figs

  9. Intraabdominal contamination after gallbladder perforation during laparoscopic cholecystectomy and its complications.

    Science.gov (United States)

    Kimura, T; Goto, H; Takeuchi, Y; Yoshida, M; Kobayashi, T; Sakuramachi, S; Harada, Y

    1996-09-01

    Gallbladder perforation often occurs during laparoscopic cholecystectomy. The frequency and causes of gallbladder perforation as well as the relevant clinical background factors were investigated in 110 patients undergoing laparoscopic cholecystectomy. We also evaluated intraperitoneal contamination by bacteria and gallstones at the time of gallbladder perforation and investigated whether perforation caused early or late postoperative complications. Intraoperative gallbladder perforation occurred in 29 of the 110 patients (26.3%). It was caused by injury with an electric knife during dissection of the gallbladder bed, injury during gallbladder retraction with grasping forceps, injury during gallbladder extraction from the abdomen, and slippage of cystic duct clips (potentially causing bile and stone spillage). Perforation was more frequent in patients with positive bile cultures and in those with pigment stones (p gallbladder perforation is sometimes unavoidable during laparoscopic cholecystectomy, the risk of severe complications appears to be minimized by early closure of perforation, retrieval of as many of the spilled stones as possible, and intraperitoneal lavage.

  10. Neutron scattering studies of mixed-valence semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Mignot, J M [Laboratoire Leon Brillouin (LLB) - Centre d` Etudes de Saclay, 91 - Gif-sur-Yvette (France); Alekseev, P A [Kurchatov Institute, Moscow (Russian Federation)

    1994-12-31

    Neutron scattering experiments on the mixed-valence (MV) compounds SmB{sub 6} are reported. The inelastic magnetic response of SmB{sub 6} at T = 2 K, measured on a double-isotope single crystal,displays a strongly damped peak at 35 meV corresponding to the inter multiplet transition of Sm{sup 2+}. At lower energies ( h.{omega} {approx_equal} 14 meV), a narrow magnetic excitation is observed, with remarkable scattering-vector and temperature dependences of its intensity. This novel feature is discussed in terms of recent theoretical works describing the formation of an anisotropic local bound state in semiconducting MV materials. If the average samarium valence is decreased by substituting La for Sm, a peak is found to appear at high energies. The elastic magnetic form factor of SmB{sub 6} was determined using polarised neutrons and no significant difference is observed in its Q-dependence with respect to that of pure divalent samarium. This surprising behaviour is constant with previous measurements on the gold (high-pressure) phase of SmS. The above results are compared to those already reported for other MV materials. In particular existing information for TmSe is supplemented by recent inelastic scattering measurements carried out on a large stoichiometric single crystal. (author). 44 refs., 7 figs.

  11. Physics with isotopically controlled semiconductors

    International Nuclear Information System (INIS)

    Haller, E.E.

    1994-08-01

    Control of the isotopic composition of semiconductors offers a wide range of new scientific opportunities. In this paper a number of recent results obtained with isotopically pure as well as deliberately mixed diamond and Ge bulk single crystals and Ge isotope superlattices will be reviewed. Isotopic composition affects several properties such as phonon energies, bandstructure and lattice constant in subtle but theoretically well understood ways. Large effects are observed for thermal conductivity, local vibrational modes of impurities and after neutron transmutation doping (NTD). Several experiments which could profit greatly from isotope control are proposed

  12. MRI of perforated gall bladder

    International Nuclear Information System (INIS)

    Sood, B.; Jain, M.; Khandelwal, N.; Singh, P.; Suri, S.

    2002-01-01

    Gall bladder perforation is a dreaded complication of acute cholecystitis that, if not diagnosed early in the course, might have a poor prognosis. Both CT and ultrasonography have been used until now extensively for the diagnosis of acute cholecystitis, but diagnosis of perforation is always difficult. Magnetic resonance, by its superior soft tissue resolution and multiplanar capability, is a better modality and should fare better than ultrasonography and CT, as demonstrated in our case. Magnetic resonance imaging demonstrates the wall of the gall bladder and defects to a much better advantage and more convincingly. In addition, MR colangiopancreatography images demonstrate the biliary tree better than other modalities. We suggest that in the case of acute cholecystitis, if perforation is suspected and CT and ultrasonography are not conclusive, MR should be the modality of choice. It can be used as a first line of investigation; however, it might not be cost-effective. Copyright (2002) Blackwell Science Pty Ltd

  13. Conducting Polymers for Neutron Detection

    International Nuclear Information System (INIS)

    Clare Kimblin; Kirk Miller; Bob Vogel; Bill Quam; Harry McHugh; Glen Anthony; Steve Jones; Mike Grover

    2007-01-01

    Conjugated polymers have emerged as an attractive technology for large-area electronic applications. As organic semiconductors, they can be used to make large-area arrays of diodes or transistors using fabrication techniques developed for polymer coatings, such as spraying and screen-printing. We have demonstrated both neutron and alpha detection using diodes made from conjugated polymers and have done preliminary work to integrate a boron carbide layer into the conventional polymer device structure to capture thermal neutrons. The polymer devices appear to be insensitive to gamma rays, due to their small physical thickness and low atomic number

  14. Optimization of the process of steel strip perforation and nickel platting for the purpose of elimination of trichloroethylene from the cleaning process of perforated steel strip

    Directory of Open Access Journals (Sweden)

    Petrović Aleksandra B.

    2009-01-01

    Full Text Available In the production of pocket type electrodes for Ni-Cd batteries perforation of proper steel strips and then nickel platting of perforated steel strips were made. In the nickel platting process, the organic solvent, trichloroethylene, has previously been used for cleaning. Due to the carcinogenic nature of trichloroethylene and the many operations previously required during cleaning, it was considered to do cleaning of perforated steel strips without use of the mentioned organic solvent. In the purpose of elimination of trichloroethylene from the cleaning process of perforated steel strips, the tests of perforation of steel strips with use of oils of different viscosity were made. It was shown that there was no dysfunction during the work of the perforation plants, meaning there was no additional heating of the strips, deterring of the steel filings, nor excessive wearing of the perforation apparatus. The perforation percent was the same irrelevant of the viscosity of the used oil. Before being perforated using the oils with different viscosity, the nickel platting steel strips were cleaned in different degreasers (based on NaOH as well as on KOH. It was shown that efficient cleaning without the use of trichloroethylene is possible with the use of oil with smaller viscosity in the perforated steel strips process and the degreaser based on KOH in the cleaning process, before nickel platting. It also appeared that the alkali degreaser based on KOH was more efficient, bath corrections were made less often and the working period of the baths was longer, which all in summary means less quantity of chemicals needed for degreasing of perforated steel strips.

  15. Fouling Resilient Perforated Feed Spacers for Membrane Filtration

    KAUST Repository

    Kerdi, Sarah

    2018-04-24

    The improvement of feed spacers with optimal geometry remains a key challenge for spiral-wound membrane systems in water treatment due to their impact on the hydrodynamic performance and fouling development. In this work, novel spacer designs are proposed by intrinsically modifying cylindrical filaments through perforations. Three symmetric perforated spacers (1-Hole, 2-Hole, and 3-Hole) were in-house 3D-printed and experimentally evaluated in terms of permeate flux, feed channel pressure drop and membrane fouling. Spacer performance is characterized and compared with standard no perforated (0-Hole) design under constant feed pressure and constant feed flow rate. Perforations in the spacer filaments resulted in significantly lowering the net pressure drop across the spacer filled channel. The 3-Hole spacer was found to have the lowest pressure drop (50% - 61%) compared to 0-Hole spacer for various average flow velocities. Regarding permeate flux production, the 0-Hole spacer produced 5.7 L.m-2.h-1 and 6.6 L.m-2.h-1 steady state flux for constant pressure and constant feed flow rate, respectively. The 1-Hole spacer was found to be the most efficient among the perforated spacers with 75% and 23% increase in permeate production at constant pressure and constant feed flow, respectively. Furthermore, membrane surface of 1-Hole spacer was found to be cleanest in terms of fouling, contributing to maintain higher permeate flux production. Hydrodynamic understanding of these perforated spacers is also quantified by performing Direct Numerical Simulation (DNS). The performance enhancement of these perforated spacers is attributed to the formation of micro-jets in the spacer cell that aided in producing enough unsteadiness/turbulence to clean the membrane surface and mitigate fouling phenomena. In the case of 1-Hole spacer, the unsteadiness intensity at the outlet of micro-jets and the shear stress fluctuations created inside the cells are higher than those observed with

  16. Fouling resilient perforated feed spacers for membrane filtration.

    Science.gov (United States)

    Kerdi, Sarah; Qamar, Adnan; Vrouwenvelder, Johannes S; Ghaffour, Noreddine

    2018-04-24

    The improvement of feed spacers with optimal geometry remains a key challenge for spiral-wound membrane systems in water treatment due to their impact on the hydrodynamic performance and fouling development. In this work, novel spacer designs are proposed by intrinsically modifying cylindrical filaments through perforations. Three symmetric perforated spacers (1-Hole, 2-Hole, and 3-Hole) were in-house 3D-printed and experimentally evaluated in terms of permeate flux, feed channel pressure drop and membrane fouling. Spacer performance is characterized and compared with standard no perforated (0-Hole) design under constant feed pressure and constant feed flow rate. Perforations in the spacer filaments resulted in significantly lowering the net pressure drop across the spacer filled channel. The 3-Hole spacer was found to have the lowest pressure drop (50%-61%) compared to 0-Hole spacer for various average flow velocities. Regarding permeate flux production, the 0-Hole spacer produced 5.7 L m -2 .h -1 and 6.6 L m -2 .h -1 steady state flux for constant pressure and constant feed flow rate, respectively. The 1-Hole spacer was found to be the most efficient among the perforated spacers with 75% and 23% increase in permeate production at constant pressure and constant feed flow, respectively. Furthermore, membrane surface of 1-Hole spacer was found to be cleanest in terms of fouling, contributing to maintain higher permeate flux production. Hydrodynamic understanding of these perforated spacers is also quantified by performing Direct Numerical Simulation (DNS). The performance enhancement of these perforated spacers is attributed to the formation of micro-jets in the spacer cell that aided in producing enough unsteadiness/turbulence to clean the membrane surface and mitigate fouling phenomena. In the case of 1-Hole spacer, the unsteadiness intensity at the outlet of micro-jets and the shear stress fluctuations created inside the cells are higher than those

  17. Ways of providing radiation resistance of magnetic field semiconductor sensors

    CERN Document Server

    Bolshakova, I A; Holyaka, R; Matkovskii, A; Moroz, A

    2001-01-01

    Hall magnetic field sensors resistant to hard ionizing irradiation are being developed for operation under the radiation conditions of space and in charged particle accelerators. Radiation resistance of the sensors is first determined by the properties of semiconductor materials of sensitive elements; we have used microcrystals and thin layers of III-V semiconductors. Applying complex doping by rare-earth elements and isovalent impurities in certain proportions, we have obtained magnetic field sensors resistant to irradiation by fast neutrons and gamma-quanta. Tests of their radiation resistance were carried out at IBR-2 at the Joint Institute for Nuclear Research (Dubna). When exposed to neutrons with E=0.1-13 MeV and intensity of 10 sup 1 sup 0 n cm sup - sup 2 s sup - sup 1 , the main parameter of the sensors - their sensitivity to magnetic fields - changes by no more than 0.1% up to fluences of 10 sup 1 sup 4 n cm sup - sup 2. Further improvement of radiation resistance of sensor materials is expected by ...

  18. Nasal Septum Perforation due to Methamphetamine abuse

    Directory of Open Access Journals (Sweden)

    Mehdi Bakhshaee

    2012-07-01

    Full Text Available Introduction: Spontaneous Perforation of the nasal septum is an uncommon condition. Nasal inhalation of substances such as cocaine has long been linked to this Perforation. Case Report: This report describes the case of a 46-year-old woman who was addicted to methamphetamine and who presented with perforation of the nasal septum.This is the first reported case of nasal septal necrosis linked to nasal inhalation of methamphetamine. Conclusions: Patient history and assurance regardingillegal drug consumption and abuse is a key point for fast and accurate diagnosis. The pathophysiology of drug-induced sinunasal disease and a review of the literature are also presented.

  19. Spectrum of perforation peritonitis in India--review of 504 consecutive cases.

    Science.gov (United States)

    Jhobta, Rajender Singh; Attri, Ashok Kumar; Kaushik, Robin; Sharma, Rajeev; Jhobta, Anupam

    2006-09-05

    Perforation peritonitis is the most common surgical emergency in India. The spectrum of etiology of perforation in Tropical countries continues to be different from its Western counterpart. The objective of the study was to highlight the spectrum of perforation peritonitis as encountered by us at Government Medical College and Hospital (GMCH), Chandigarh. Five hundred and four consecutive cases of perforation peritonitis over a period of five years were reviewed in terms of clinical presentation, operative findings and postoperative course retrospectively at GMCH, Chandigarh. The most common cause of perforation in our series was perforated duodenal ulcer (289 cases) followed by appendicitis (59 cases), gastrointestinal perforation due to blunt trauma abdomen (45 cases), typhoid fever (41 cases) and tuberculosis (20 cases). Despite delay in seeking medical treatment (53%), the overall mortality (10%) was favourably comparable with other published series though the overall morbidity (50%) was unusually high. In contrast to western literature, where lower gastrointestinal tract perforations predominate, upper gastrointestinal tract perforations constitute the majority of cases in India. The increasing incidence of post-traumatic gastro-enteric injuries may be due to an increase in high speed motor vehicle accidents which warrant early recognition and prompt treatment to avoid serious complications and death.

  20. Spectrum of perforation peritonitis in India-review of 504 consecutive cases

    Directory of Open Access Journals (Sweden)

    Sharma Rajeev

    2006-09-01

    Full Text Available Abstract Background/objective Perforation peritonitis is the most common surgical emergency in India. The spectrum of etiology of perforation in Tropical countries continues to be different from its Western counterpart. The objective of the study was to highlight the spectrum of perforation peritonitis as encountered by us at Government Medical College and Hospital (GMCH, Chandigarh. Methods Five hundred and four consecutive cases of perforation peritonitis over a period of five years were reviewed in terms of clinical presentation, operative findings and postoperative course retrospectively at GMCH, Chandigarh. Results The most common cause of perforation in our series was perforated duodenal ulcer (289 cases followed by appendicitis (59 cases, gastrointestinal perforation due to blunt trauma abdomen (45 cases, typhoid fever (41 cases and tuberculosis (20 cases. Despite delay in seeking medical treatment (53%, the overall mortality (10% was favourably comparable with other published series though the overall morbidity (50% was unusually high. Conclusion In contrast to western literature, where lower gastrointestinal tract perforations predominate, upper gastrointestinal tract perforations constitute the majority of cases in India. The increasing incidence of post-traumatic gastro-enteric injuries may be due to an increase in high speed motor vehicle accidents which warrant early recognition and prompt treatment to avoid serious complications and death.

  1. Contact lens rehabilitation following repaired corneal perforations

    Science.gov (United States)

    Titiyal, Jeewan S; Sinha, Rajesh; Sharma, Namrata; Sreenivas, V; Vajpayee, Rasik B

    2006-01-01

    Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60%) required aphakic contact lenses. The best corrected visual acuity (BCVA) of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25%) eyes with spectacle correction and 37 (92.5%) eyes with the use of contact lens (p < 0.001). The best-corrected visual acuity with spectacles was 0.20 ± 0.13 while the same with contact lens was 0.58 ± 0.26. All the patients showed an improvement of ≥ 2 lines over spectacles in the snellen's acuity chart with contact lens. Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries. PMID:16536877

  2. Frequency of wound infection in non-perforated appendicitis with use of single dose perforative antibiotics

    International Nuclear Information System (INIS)

    Ali, K.; Latif, H.; Ahmad, S.

    2015-01-01

    Antibiotics are used both pre and post-operatively in acute appendicitis for preventing wound infection. It has been observed that the routine use of post-operative antibiotics is not necessary in cases of non-perforated appendicitis as only prophylactic antibiotics are sufficient to prevent wound infection. The aim of this study was to see the frequency of wound infection in non-perforated appendicitis with single dose preoperative antibiotics only. Method: This observational study was conducted at the Department of Surgery, Ayub Medical College, Abbottabad from May to November 2014. A total of 121 patients with non-perforated appendicitis were included in the study. Only single dose preoperative antibiotics were used. The patients were followed for wound infection till 8th post-operative day. Results: 121 patients, 56(46.28%) male and 65(53.72%) female were included in the study. The mean age of patients was 27.41 ± 7.12 years with an age range of 18 to 45 years. In the entire series, 7(5.78%) patients developed wound infection. The infection was minor which settled with conservative therapy. Prophylactic antibiotics were found efficacious in 114(94.21%) patients. There was no significant association between wound infection and age and gender. Conclusion: Single dose preoperative antibiotics were found effective in controlling post-operative wound infection without the need of extending the antibiotics to post-operative period in cases of non-perforated appendicitis. (author)

  3. Preoperative chest x-ray findings in peptic ulcer perforation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. H.; Kim, S. W.; Lim, J. S.; Kim, Y. J. [Kyungpook National University School of Medicine, Taegu (Korea, Republic of)

    1981-12-15

    This study was carried out to analyze the distribution of age, sex, chief complaint, physical examination and findings of chest x-ray films before operation in 59 cases of peptic ulcer perforation. The ratio of male to female was 1.7 : 1 and incidence of the ulcer perforation was most common in 5th decades. Thirty five among 59 cases showed pleural effusion, segmental atelectasis and pneumonic infiltration on chest x-ray film. Twenty nine among 50 cases of duodenal ulcer perforation and 6 of 9 cases of stomach ulcer perforation showed positive chest x-ray findings. No relationship was found between fever and preoperative chest x-ray findings.

  4. Preoperative chest x-ray findings in peptic ulcer perforation

    International Nuclear Information System (INIS)

    Kim, T. H.; Kim, S. W.; Lim, J. S.; Kim, Y. J.

    1981-01-01

    This study was carried out to analyze the distribution of age, sex, chief complaint, physical examination and findings of chest x-ray films before operation in 59 cases of peptic ulcer perforation. The ratio of male to female was 1.7 : 1 and incidence of the ulcer perforation was most common in 5th decades. Thirty five among 59 cases showed pleural effusion, segmental atelectasis and pneumonic infiltration on chest x-ray film. Twenty nine among 50 cases of duodenal ulcer perforation and 6 of 9 cases of stomach ulcer perforation showed positive chest x-ray findings. No relationship was found between fever and preoperative chest x-ray findings

  5. Prediction of inelastic behavior and creep-fatigue life of perforated plates

    International Nuclear Information System (INIS)

    Igari, Toshihide; Setoguchi, Katsuya; Nakano, Shohki; Nomura, Shinichi

    1991-01-01

    Prediction methods of macroscopic and local stress-strain behavior of perforated plates in plastic and creep regime which are proposed by the authors are applied to the inelastic analysis and creep-fatigue life prediction of perforated cylinder subjected to cyclic thermal stress. Stress-strain behavior of perforated cylinder is analyzed by modeling the perforated portion to cylinder with equivalent-solid-plate properties. Creep-fatigue lives at around a hole of perforated plates are predicted by using the local stress-strain behavior and are compared with experimentally observed lives. (author)

  6. Primary Closure versus Gastric Resection for Perforated Gastric

    African Journals Online (AJOL)

    Perforated gastric ulcer is one of the most life‑threatening complications of peptic ulcer disease with high .... tubes were removed and oral nutrition resumed. The .... surgical approach for perforated gastric cancer: One‑stage vs. two‑stage ...

  7. Study on Dynamic Response of Downhole Tools under Perforation Impact Load

    Directory of Open Access Journals (Sweden)

    Liu Jun

    2017-01-01

    Full Text Available A model of a multibody system is established to investigate the dynamic response of an oil tube-shock absorber-perforating gun system in downhole perforation-test joint operation. In the model, the oil tube and perforating gun are modeled as elastic rods and the shock absorber is modeled as single particle system with damping and a spring. Two force continuity conditions are used to simulate the interactions among the three components. The perforation impact load is determined by an experiment of underwater explosion of perforating bullets. Using the model, the effects of charge quantity of perforating bullet, the number of shock absorbers, and the length of oil tube on the dynamic response of oil tube and packer are investigated. On this basis, a basic principle of the combination design of shock absorber and oil tube is proposed to improve the mechanical state of downhole tools. The study results can provide theoretical support for the design of downhole perforation-test joint operation.

  8. Preliminary neutron design of the flux flatter for silicon doping at the RA10

    International Nuclear Information System (INIS)

    Cintas, A.; Bazzana, S.

    2012-01-01

    The neutron transmutation doping of silicon (NTD) is one of the facilities under development for the RA10 project. In order to obtain high quality semiconductor, commercial requirements of NTD include achieving high axial and radial uniformity in the silicon targets. Axial uniformity is achieved locating a neutron screen around the Si ingot, obtaining a flat axial distribution of the dopant concentration. We present the neutron design of this screen, also known as flux flattener. MCNP5 was used to model the screen design. We have reached a satisfactory preliminary screen design after numerous iterations. The fluctuation in the axial distribution of the reaction capture rate ( 30 Si(n,γ) 31 Si) is under ≠1,5%, which is the required level by the semiconductor industry to accept the final product (author)

  9. Clinical Factors of Delayed Perforation after Endoscopic Submucosal Dissection for Gastric Neoplasms

    Directory of Open Access Journals (Sweden)

    Yoshinobu Yamamoto

    2017-01-01

    Full Text Available Background. Delayed perforation is a rare but severe complication of endoscopic submucosal dissection (ESD for early gastric neoplasm (EGN. The aim of this study was to clarify clinical factors related to delayed perforation after ESD. Methods. A total of 1158 consecutive patients with 1199 EGNs underwent ESD at our hospital between January 2000 and December 2015. Univariate analysis was used to identify clinicopathological factors related to delayed perforation. Moreover, duration of cautery needed for hemostasis was measured by comparison between perforated and nonperforated points in patients with delayed perforation. Results. Delayed perforation occurred in 5 of 1158 consecutive patients with 1199 EGNs who underwent ESD (0.42%. All cases were diagnosed within 24 h after ESD and recovered with conservative management. On univariate analysis, location in the upper stomach was the factor most significantly associated with delayed perforation (P<0.01. Duration of cautery needed for hemostasis was significantly longer at perforated points (9 s than at nonperforated points (3.5 s in five patients. Conclusions. Location in the upper stomach was the risk factor most prominently associated with delayed perforation after ESD for EGNs. In addition, delayed perforation appears associated with excessive electrocautery for hemostasis.

  10. Clinicopathological Analysis of Factors Related to Colorectal Tumor Perforation

    OpenAIRE

    Medina-Arana, Vicente; Martínez-Riera, Antonio; Delgado-Plasencia, Luciano; Rodríguez-González, Diana; Bravo-Gutiérrez, Alberto; Álvarez-Argüelles, Hugo; Alarcó-Hernández, Antonio; Salido-Ruiz, Eduardo; Fernández-Peralta, Antonia M.; González-Aguilera, Juan J.

    2015-01-01

    Abstract Colorectal tumor perforation is a life-threatening complication of this disease. However, little is known about the anatomopathological factors or pathophysiologic mechanisms involved. Pathological and immunohistochemical analysis of factors related with tumoral neo-angiogenesis, which could influence tumor perforation are assessed in this study. A retrospective study of patients with perforated colon tumors (Group P) and T4a nonperforated (controls) was conducted between 2001 and 20...

  11. Predictors of appendiceal perforation in an equal access system.

    Science.gov (United States)

    Walker, Avery; Hatch, Quinton; Drake, Thurston; Nelson, Daniel W; Fitzpatrick, Emilie; Bingham, Jason; Black, George; Maykel, Justin A; Steele, Scott R

    2014-07-01

    Discrepancies in socioeconomic factors have been associated with higher rates of perforated appendicitis. As an equal-access health care system theoretically removes these barriers, we aimed to determine if remaining differences in demographics, education, and pay result in disparate outcomes in the rate of perforated appendicitis. All patients undergoing appendectomy for acute appendicitis (November 2004-October 2009) at a tertiary care equal access institution were categorized by demographics and perioperative data. Rank of the sponsor was used as a surrogate for economic status. A multivariate logistic regression model was performed to determine patient and clinical characteristics associated with perforated appendicitis. A total of 680 patients (mean age 30±16 y; 37% female) were included. The majority were Caucasian (56.4% [n=384]; African Americans 5.6% [n=38]; Asians 1.9% [n=13]; and other 48.9% [n=245]) and enlisted (87.2%). Overall, 6.4% presented with perforation, with rates of 6.6%, 5.8%, and 6.7% (P=0.96) for officers, enlisted soldiers, and contractors, respectively. There was no difference in perforation when stratified by junior or senior status for either officers or enlisted (9.3% junior versus 4.40% senior officers, P=0.273; 6.60% junior versus 5.50% senior enlisted, P=0.369). On multivariate analysis, parameters such as leukocytosis and temperature, as well as race and rank were not associated with perforation (P=0.7). Only age had a correlation, with individuals aged 66-75 y having higher perforation rates (odds ratio, 1.04; 95% confidence interval, 1.02-1.05; P<0.001). In an equal-access health care system, older age, not socioeconomic factors, correlated with increased appendiceal perforation rates. Published by Elsevier Inc.

  12. Capture analysis of element content of a substance with other neutron methods

    International Nuclear Information System (INIS)

    Kurbanov, B.I.

    2004-01-01

    Full text: Neutron analysis method of determining element composition have found wide range of applications in industry thanks to different types of interaction of neutron with substances /1/. With the aim of widening the range of problems to be solved, on the basis of the device /2/ for determining the element content of substance, possibilities of combining the method based on the use of neutron capture gamma-ray spectrometry with other neutron methods, in particular neutron activation analysis and neutron absorption analysis were studied. In this radionuclide source ( 252 Cf) with the yield of 1,5 x 10 7 neutron/sec is used. By means of using neutron capture gamma radiation spectrometry the possibilities of determining some elements (H, B, N, S etc. ), which are not determined by very widely used method, activation analysis. These elements can be determined by both the semiconductor and scintillation detectors with parameters fitting the manufacturing requirements. And for a number of elements ( B, Cl, Cd, Sm, Gd) very high limits of determination ( up to 10- 5 %) are possible using semiconductor Ge (Li) -detectors with high resolution. Possibility of determination of some 'well' activated elements ( K, Al, Fe, Mn, Ti, Sc etc.) in samples of ore and products of their processing using the neutron-activation analysis. For 1 hour of irradiation on the experimental device quite accurate analytical peak, of these elements are obtained, allowing to determine them qualitatively. However, with decreasing neutron yield of radionuclide source it becomes more difficult to achieve the necessary parameters both in neutron capture and activation analysis. Experimental works on determination of some elements with large cross-sections of capture ( B, Cd, Sm ) by absorption of neutrons in the investigated substance, i.e. using the neutron absorption analysis method with absence of other large capture cross section elements in the samples being studied

  13. Silicon photo-multiplier radiation hardness tests with a beam controlled neutron source

    International Nuclear Information System (INIS)

    Angelone, M.; Pillon, M.; Faccini, R.; Pinci, D.; Baldini, W.; Calabrese, R.; Cibinetto, G.; Cotta Ramusino, A.; Malaguti, R.; Pozzati, M.

    2010-01-01

    Radiation hardness tests were performed at the Frascati Neutron Generator on silicon Photo-Multipliers that were made of semiconductor photon detectors built from a square matrix of avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated, integrating up to 7x10 10 1-MeV-equivalent neutrons per cm 2 . Detector performance was recorded during the neutron irradiation, and a gradual deterioration of their properties began after an integrated fluence of the order of 10 8 1-MeV-equivalent neutrons per cm 2 was reached.

  14. Influence of operating microscope in the sealing of cervical perforations.

    Science.gov (United States)

    Schmidt, Bruna Schwingel; Zaccara, Ivana Maria; Reis Só, Marcus Vinícius; Kuga, Milton Carlos; Palma-Dibb, Regina Guenka; Kopper, Patrícia Maria Poli

    2016-01-01

    Accidental root canal perforations are among the main complications of endodontic treatment. This study evaluated the influence of operating microscope (OM) in the marginal adaptation of mineral trioxide aggregate (MTA) (Angelus(®)) and glass ionomer (Vitremer) inserted into cervical perforations. Perforations were made in the cervical third of the buccal wall of the root canal in mandibular incisors. Next, the teeth were divided into four groups (N = 10): MG - MTA without OM; VG - Vitremer without OM; MOMG - MTA with OM; VOMG - Vitremer with OM. The perforations were sealed according to the group and the teeth were prepared for analysis by confocal laser scanning microscope. Images of perforation region (1,024×) were made and the gap presented by the materials was measured using the Image J program. LEXT OLS4100 three dimensional (3D) measuring laser microscope measured the volumetric misfit. Data of gap were analyzed by Kruskal-Wallis and Dunn's tests. Analysis of variance (ANOVA) and Tukey's tests compared the volumetric misfits. The results showed lower volume and gap in the interface dentin/material in VOMG compared to the other groups (P < 0.05). The use of OM improved the quality of cervical perforations sealed with Vitremer, being indicated in clinical situations of iatrogenic cervical perforations.

  15. Laparoscopic Primary Colorrhaphy for Acute Iatrogenic Perforations during Colonoscopy

    Directory of Open Access Journals (Sweden)

    Eric M. Haas

    2013-01-01

    Full Text Available Purpose. We present our experience with laparoscopic colorrhaphy as definitive surgical modality for the management of colonoscopic perforations. Methods. Over a 17-month period, we assessed the outcomes of consecutive patients presenting with acute colonoscopic perforations. Patient characteristics and perioperative parameters were tabulated. Postoperative outcomes were evaluated within 30 days following discharge. Results. Five female patients with a mean age of 71.4 ± 9.7 years (range: 58–83, mean BMI of 26.4 ± 3.4 kg/m2 (range: 21.3–30.9, and median ASA score of 2 (range: 2-3 presented with acute colonoscopic perforations. All perforations were successfully managed through laparoscopic colorrhaphy within 24 hours of development. The perforations were secondary to direct trauma (n=3 or thermal injury (n=2 and were localized to the sigmoid (n=4 or cecum (n=1. None of the patients required surgical resection, diversion, or conversion to an open procedure. No intra- or postoperative complications were encountered. The mean length of hospital stay was 3.8 ± 0.8 days (range: 3–5. There were no readmissions or reoperations. Conclusion. Acute colonoscopic perforations can be safely managed via laparoscopic primary repair without requiring resection or diversion. Early recognition and intervention are essential for successful outcomes.

  16. Semiconductor

    International Nuclear Information System (INIS)

    2000-01-01

    This book deals with process and measurement of semiconductor. It contains 20 chapters, which goes as follows; semiconductor industry, introduction of semiconductor manufacturing, yield of semiconductor process, materials, crystal growth and a wafer forming, PN, control pollution, oxidation, photomasking photoresist chemistry, photomasking technologies, diffusion and ion injection, chemical vapor deposition, metallization, wafer test and way of evaluation, semiconductor elements, integrated circuit and semiconductor circuit technology.

  17. Esophageal Perforation due to Transesophageal Echocardiogram: New Endoscopic Clip Treatment

    Directory of Open Access Journals (Sweden)

    John Robotis

    2014-07-01

    Full Text Available Esophageal perforation due to transesophageal echocardiogram (TEE during cardiac surgery is rare. A 72-year-old female underwent TEE during an operation for aortic valve replacement. Further, the patient presented hematemesis. Gastroscopy revealed an esophageal bleeding ulcer. Endoscopic therapy was successful. Although a CT scan excluded perforation, the patient became febrile, and a second gastroscopy revealed a big perforation at the site of ulcer. The patient's clinical condition required endoscopic intervention with a new OTSC® clip (Ovesco Endoscopy, Tübingen, Germany. The perforation was successfully sealed. The patient remained on intravenous antibiotics, proton pump inhibitors and parenteral nutrition for few days, followed by enteral feeding. She was discharged fully recovered 3 months later. We clearly demonstrate an effective, less invasive treatment of an esophageal perforation with a new endoscopic clip.

  18. Perforated duodenal diverticulum caused by Bezoar: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Jung; Moon, Sung Kyoung; Park, Seong Jin; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae [Dept. of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    2013-11-15

    Duodenal diverticulum is common, but its perforation is a rare complication. Duodenal diverticulum perforation requires prompt treatments because of its high mortality rate. However, an accurate diagnosis is difficult to make due to nonspecific symptoms and signs. It can be misdiagnosed as pancreatitis, cholecystitis, or peptic ulcer. Herein, we report a case of perforated duodenal diverticulum caused by bezoar in a 33-year-old woman whom was diagnosed by abdomen computed tomography and ultrasonography.

  19. Duodenal perforation: an unusual complication of sickle cell anemia

    OpenAIRE

    Acıpayam, Can; Aldıç, Güliz; Akçora, Bülent; Çelikkaya, Mehmet Emin; Aşkar, Hasan; Dorum, Bayram Ali

    2014-01-01

    Duodenal perforation in childhood is a rare condition with a high mortality rate if not treated surgically. Primary gastroduodenal perforation is frequently associated with peptic ulcer and exhibits a positive family history. Helicobacter pylorus is the most significant agent. Secondary gastroduodenal perforation may be a finding of specific diseases, such as Crohn disease, or more rarely may be associated with diseases such as cystic fibrosis or sickle cell anemia. A 14-year-old boy presente...

  20. Spectrum of Perforation Peritonitis in Delhi: 77 Cases Experience

    OpenAIRE

    Yadav, Dinesh; Garg, Puneet K.

    2012-01-01

    Perforation peritonitis is the most common surgical emergency encountered by surgeons all over the world as well in India. The spectrum of etiology of perforation peritonitis in tropical countries continues to differ from its western counterpart. This study was conducted at Hindu Rao Hospital, Municipal Corporation of Delhi, New Delhi, India, designed to highlight the spectrum of perforation peritonitis in the eastern countries and to improve its outcome. This prospective study included 77 co...

  1. Perforated duodenal diverticulum caused by Bezoar: A case report

    International Nuclear Information System (INIS)

    Lee, Eun Jung; Moon, Sung Kyoung; Park, Seong Jin; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae

    2013-01-01

    Duodenal diverticulum is common, but its perforation is a rare complication. Duodenal diverticulum perforation requires prompt treatments because of its high mortality rate. However, an accurate diagnosis is difficult to make due to nonspecific symptoms and signs. It can be misdiagnosed as pancreatitis, cholecystitis, or peptic ulcer. Herein, we report a case of perforated duodenal diverticulum caused by bezoar in a 33-year-old woman whom was diagnosed by abdomen computed tomography and ultrasonography.

  2. Perforated peptic ulcer

    Science.gov (United States)

    Søreide, Kjetil; Thorsen, Kenneth; Harrison, Ewen M.; Bingener, Juliane; Møller, Morten H.; Ohene-Yeboah, Michael; Søreide, Jon Arne

    2015-01-01

    Summary Perforated peptic ulcer (PPU) is a frequent emergency condition worldwide with associated mortality up to 30%. A paucity of studies on PPU limits the knowledge base for clinical decision-making, but a few randomised trials are available. While Helicobacter pylori and use of non-steroidal anti-inflammatory drugs are frequent causes of PPU, demographic differences in age, gender, perforation location and aetiology exist between countries, as do mortality rates. Clinical prediction rules are used, but accuracy varies with study population. Early surgery, either by laparoscopic or open repair, and proper sepsis management are essential for good outcome. Selected patients can perhaps be managed non-operatively or with novel endoscopic approaches, but validation in trials is needed. Quality of care, sepsis care-bundles and postoperative monitoring need further evaluation. Adequate trials with low risk of bias are urgently needed for better evidence. Here we summarize the evidence for PPU management and identify directions for future clinical research. PMID:26460663

  3. Surgical management of perforated duodenal ulcer: the changing scene.

    Science.gov (United States)

    Plummer, J M; McFarlane, M E C; Newnham

    2004-12-01

    To determine the management of perforated duodenal ulcer at the University Hospital of the West Indies (UHWI) in this era of Helicobacter pylori, the medical records of all patients seen at the UHWI during the period July 1997 to June 2002 with an intra-operative diagnosis of perforated peptic ulcer were reviewed The records were analyzed for the following: age, gender, duration of symptoms, non-steroidal anti-inflammatory drug (NSAID) use, smoking status, operative repair duration of hospitalization, Helicobacter pylori status and medical therapy, peri-operative complications, mortality and recurrence. Ninety per cent of the cases were males. All females in whom perforation occurred were age 50 years and older compared to males where 58% of cases presented before age 50 years. Perforations in acute ulcers occurred in 80% of cases. The majority of patients were male smokers. Non-steroidal anti-inflammatory drug use was also an important risk factor in elderly females. Simple surgical closure and standard triple therapy antibiotics to eradicate Helicobacter pylori was the most common treatment offered. Mortality was one per cent and follow-up poor but 11% of patients had documented recurrent peptic ulceration. In this study population, perforated duodenal ulcer occured overwhelmingly in males less than 50 years of age. There is a trend towards exclusive simple surgical closure and H pylori eradication at the UHWI for patients with perforated duodenal ulcer but this needs to be supported by documentation of H pylori prevalence in the population of patients presenting with perforated peptic ulcers.

  4. Factors related to persisting perforations after ventilation tube insertion.

    Science.gov (United States)

    O'Connell Ferster, Ashley P; Tanner, April Michelle; Karikari, Kodjo; Roberts, Christopher; Wiltz, Derek; Carr, Michele M

    2016-02-01

    Over a million ventilation tubes are placed annually in the United States, making this one of the most commonly performed procedures in the field of medicine. Certain factors increase the risk of persistent tympanic membrane perforation following the extrusion of short term ventilation tubes. Persistent perforations may fail to heal on their own, necessitating surgical closure to avoid conductive hearing loss. It is important to detect factors that may predict children who are at increased risk for persistent perforations. This study was a retrospective chart review that involved 757 patients between 2003 and 2008. The patients studied were within the age of 2 months-17 years, and all had short term tubes placed. The chart data also included demographic information, comorbidities, and information related to tube insertion and follow-up care. Chi-square, t-test, and multivariate logistic regression were conducted to compare variables between patients with perforations and those without. Data from 757 patients was analyzed, showing that perforation rate is associated with rhinorrhea, operative tube removal, aural polyps, and otorrhea (OR 1.72, 8.16, 4.69, and 1.72 respectively). The absence of otorrhea decreased the likelihood of TM perforations and no significant differences were found in gender, total number of sets of tubes, type of tube, use of nasal steroids, adenoidectomy, or nasal congestion. Our findings suggest that children with rhinorrhea, otorrhea, aural polyps, or prolonged intubation requiring operative tube removal should be identified clinically as children at risk of persisting perforation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Common Bile Duct Perforation Due to Tuberculosis: A Case Report

    OpenAIRE

    Razman Jarmin; Shaharin Shaharuddin

    2004-01-01

    A young man with HIV presented with biliary peritonitis secondary to spontaneous common bile duct perforation. Investigation revealed that the perforation was due to Mycobacterium tuberculosis. Tuberculosis of the bile duct is uncommon and usually presents with obstructive jaundice due to stricture. Bile duct perforation due to tuberculosis is extremely rare. Its management is discussed.

  6. Spectrum of perforation peritonitis in India-review of 504 consecutive cases

    OpenAIRE

    Jhobta, Rajender Singh; Attri, Ashok Kumar; Kaushik, Robin; Sharma, Rajeev; Jhobta, Anupam

    2006-01-01

    Abstract Background/objective Perforation peritonitis is the most common surgical emergency in India. The spectrum of etiology of perforation in Tropical countries continues to be different from its Western counterpart. The objective of the study was to highlight the spectrum of perforation peritonitis as encountered by us at Government Medical College and Hospital (GMCH), Chandigarh. Methods Five hundred and four consecutive cases of perforation peritonitis over a period of five years were r...

  7. Diaphragmatic eventration complicated by gastric volvulus with perforation

    OpenAIRE

    Gupta, V; Chandra, A; Gupta, P

    2012-01-01

    Eventration of the diaphragm with gastric volvulus is uncommon. Gastric perforation in these cases is rare and usually associated with acute gastric volvulus with strangulation. We describe a case of diaphragmatic eventration with chronic gastric volvulus with gastric perforation without strangulation in an elderly man.

  8. Common Bile Duct Perforation Due to Tuberculosis: A Case Report

    Directory of Open Access Journals (Sweden)

    Razman Jarmin

    2004-10-01

    Full Text Available A young man with HIV presented with biliary peritonitis secondary to spontaneous common bile duct perforation. Investigation revealed that the perforation was due to Mycobacterium tuberculosis. Tuberculosis of the bile duct is uncommon and usually presents with obstructive jaundice due to stricture. Bile duct perforation due to tuberculosis is extremely rare. Its management is discussed.

  9. Preoperative factors influencing mortality and morbidity in peptic ulcer perforation.

    Science.gov (United States)

    Sivaram, P; Sreekumar, A

    2018-04-01

    Perforated peptic ulcer is one of the most common surgical emergencies worldwide. With the improvement in medical therapy for peptic ulcers, the number of elective surgical procedures has come down. However, the incidence of perforated peptic ulcer is still increasing and remains as a substantial health problem with significant postoperative morbidity and mortality. This study aimed to find out the association between various preoperative and intraoperative factors with the postoperative mortality and morbidity in patients operated for peptic ulcer perforation. This prospective observational study had a time based sample of 101 perforation peritonitis cases admitted to the surgical wards of a tertiary care center from February 2015 to January 2016 who underwent laparotomy, diagnosed to have peptic ulcer perforation and underwent simple closure with an omental patch. Data regarding age, gender, presenting complaints, time elapsed from the onset of symptoms to surgery, physical examination findings, comorbid diseases, laboratory and imaging findings, intraoperative findings, length of hospital stay, postoperative morbidity, and mortality were recorded and analyzed. Female gender, older age group, perforation surgery interval more than 36 h, and size of perforation more than 1 cm 2 were found to be significant factors influencing postoperative mortality and morbidity. Postoperative morbidity was also associated with comorbid diseases. Abnormal renal function on presentation was identified as an additional risk factor for postoperative morbidity and longer hospital stay. An understanding of these factors, identification of patients at risk and early intervention can help in reducing the postoperative morbidity and mortality in peptic ulcer perforation.

  10. Jejunal Diverticular Perforation due to Enterolith

    Directory of Open Access Journals (Sweden)

    Ronaldo Nonose

    2011-08-01

    Full Text Available Jejunal diverticulosis is a rare entity with variable clinical and anatomical presentations. Although there is no consensus on the management of asymptomatic jejunal diverticular disease, some complications are potentially life-threatening and require early surgical treatment. Small bowel perforation secondary to jejunal diverticulitis by enteroliths is rare. The aim of this study was to report a case of small intestinal perforation caused by a large jejunal enterolith. An 86-year-old woman was admitted with signs of diffuse peritonitis. After initial fluid recovery the patient underwent emergency laparotomy. The surgery showed that she had small bowel diverticular disease, mainly localized in the proximal jejunum. The peritonitis was due to intestinal perforation caused by an enterolith 12 cm in length, localized inside one of these diverticula. The intestinal segment containing the perforated diverticulum with the enterolith was removed and an end-to-end anastomosis was done to reconstruct the intestinal transit. The patient recovered well and was discharged from hospital on the 5th postoperative day. There were no signs of abdominal pain 1 year after the surgical procedure. Although jejunal diverticular disease with its complications, such as formation of enteroliths, is difficult to suspect in patients with peritonitis, it should be considered as a possible source of abdominal infection in the elderly patient when more common diagnoses have been excluded.

  11. Sonographic templates of newborn perforator stroke.

    Science.gov (United States)

    Abels, Lyanne; Lequin, Maarten; Govaert, Paul

    2006-07-01

    Many paediatric strokes occur in the perinatal period. Improvement in neuroimaging has increased detection in newborns with neurological symptoms. To define sonographic templates of neonatal stroke in the territory of perforators of the anterior choroidal artery (AChA) and the anterior (ACA), middle (MCA) and posterior (PCA) cerebral arteries. In 24 neonates with perforator stroke, we retrospectively studied antenatal and perinatal events. Brain sonography was performed with an 8.5-MHz probe. Only hyperechoic lesions in the thalamus and/or striatum and/or centrum semiovale were included. MRI was obtained using a 1.5-T machine. We detected 28 perforator strokes in 24 infants (6 preterm): 5 MCA medial striate, 8 MCA lateral striate, 3 MCA centrum semiovale, 4 ACA Heubner's, 5 PCA thalamic arteries, 1 AChA, and 2 hypothalamic perforators. We attributed clinical seizures to stroke in two infants only. Catheter-related embolism (certain in three, possible in six others) and birth trauma (two) were probable causes. Specific conditions were found in six others. Only one infant (in nine evaluated) had an increased prothrombotic risk (fII mutation). In describing the lesions, we focused on the templates of infarction as seen in a parasagittal US sweep. Infarcts were confirmed by MRI in 21 patients. Our study showed that infarct topography can be evaluated reliably with brain sonography. This is important given the asymptomatic character of most lesions.

  12. Sen perforation af tyndtarm efter laparoskopisk gastrisk bypass

    DEFF Research Database (Denmark)

    Spanager, Lene; Sigild, Ulf Henrik; Neuenschwander, Anders Ulrich

    2010-01-01

    We present two cases in which the patients were admitted to a local hospital with acute abdominal pain four or five months after having undergone laparoscopic gastric bypass. In both cases, operation revealed a perforation of the small bowel close to the distal anastomosis. In the first case......, a massive constipation of the small bowel was most likely a contributing factor. In the second case, the cause was a kink of the entero-entero anastomosis leading to obstruction and finally perforation of the biliary limp. Late perforations are among the rarely reported complications associated with gastric...

  13. Equivalent Young's Modulus of Perforated Shell with Square Penetration Pattern

    Energy Technology Data Exchange (ETDEWEB)

    Jhung, Myung Jo; Ryu, Yong Ho [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2011-05-15

    The analysis of a plate or shell perforated with a large number of holes, by finite element method for instance, was a very costly and time-consuming technique which solves only one particular problem. But it is possible to model the perforated plate or shell and to analyze it and it is no more time-consuming theses days due to the rapid development of the computer and software. However, if a perforated plate or shell is submerged in fluid it is almost impossible to model and analyze it as is and the fluid at the same time, which is needed to investigate the effect of the fluid structure interaction. The simplest way to avoid time consuming and costly analysis of perforated plate or shell submerged in fluid is to replace the perforated plate or shell by an equivalent solid one considering weakening effect of holes. Many authors have proposed experimental or theoretical method to solve this problem for the plate. Slot and O'Donnell determined the effective elastic constants for the thick perforated plates by equating strains in the equivalent solid material to the average strains in the perforated material. O'Donnell also presented those of thin perforated plates. These results are implemented in Article A-8000 of Appendix A to the ASME code Section III, which contains a method of analysis for flat perforated plates when subjected to directly applied loads or loadings resulting from structural interaction with adjacent members. Unfortunately the effective elastic constants for the perforated shell are not found in any references. Therefore in this study the modal characteristics of the perforated shell are investigated and the equivalent material properties of perforated shell are suggested by performing several finite element analyses with respect to the ligament efficiencies

  14. Perforated pyloroduodenal peptic ulcer and sonography.

    Science.gov (United States)

    Kuzmich, Siarhei; Harvey, Chris J; Fascia, Daniel T M; Kuzmich, Tatsiana; Neriman, Deena; Basit, Rizwan; Tan, Kai Lee

    2012-11-01

    The purpose of this article is to illustrate the spectrum of sonographic findings in perforated pyloroduodenal peptic ulcer and discuss the potential role of sonography in the diagnosis. Although sonography is not the first-line investigation of choice in suspected perforated peptic ulcer, understanding of the characteristic appearances seen during general abdominal sonography may aid the reader in the diagnosis of this important and sometimes overlooked cause of nonspecific abdominal pain. This may shorten time to the diagnosis and ultimate surgical management.

  15. Spontaneous Uterine Perforation due to Pyometra Presenting as Acute Abdomen

    Directory of Open Access Journals (Sweden)

    Loabat Geranpayeh

    2006-01-01

    Full Text Available Spontaneous perforation of the uterus is rare, its incidence being about 0.01%–0.05%. We report a rare case of diffuse peritonitis caused by spontaneously perforated pyometra. A 63-year-old woman with severe abdominal pain was admitted to our hospital. Laparotomy was performed because of the suspicion of gastrointestinal perforation with generalized peritonitis. At laparotomy, about 900 mL of pus was found in the peritoneal cavity. There were no abnormal findings in the alimentary tract, liver, or gallbladder. A total abdominal hysterectomy with bilateral salpingo-oophorectomy was performed. Pathological investigation of the surgical specimen revealed endometritis and myometritis of the uterus; but there was no evidence of malignancy, and the cervical canal was patent. Although spontaneously perforated pyometra is rare, a perforated pyometra should therefore also be considered when elderly women present with acute abdominal pain.

  16. Risk of surgical glove perforation in oral and maxillofacial surgery.

    Science.gov (United States)

    Kuroyanagi, N; Nagao, T; Sakuma, H; Miyachi, H; Ochiai, S; Kimura, Y; Fukano, H; Shimozato, K

    2012-08-01

    Oral and maxillofacial surgery, which involves several sharp instruments and fixation materials, is consistently at a high risk for cross-contamination due to perforated gloves, but it is unclear how often such perforations occur. This study aimed to address this issue. The frequency of the perforation of surgical gloves (n=1436) in 150 oral and maxillofacial surgeries including orthognathic surgery (n=45) was assessed by the hydroinsufflation technique. Orthognathic surgery had the highest perforation rate in at least 1 glove in 1 operation (91.1%), followed by cleft lip and palate surgery (55.0%), excision of oral soft tumour (54.5%) and dental implantation (50.0%). The perforation rate in scrub nurses was 63.4%, followed by 44.4% in surgeons and first assistants, and 16.3% in second assistants. The odds ratio for the perforation rate in orthognathic surgery versus other surgeries was 16.0 (95% confidence interval: 5.3-48.0). The protection rate offered by double gloving in orthognathic surgery was 95.2%. These results suggest that, regardless of the surgical duration and blood loss in all fields of surgery, orthognathic surgery must be categorized in the highest risk group for glove perforation, following gynaecological and open lung surgery, due to the involvement of sharp objects. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Perforated peptic ulcer associated with abdominal compartment syndrome.

    Science.gov (United States)

    Lynn, Jiun-Jen; Weng, Yi-Ming; Weng, Chia-Sui

    2008-11-01

    Abdominal compartment syndrome (ACS) is defined as an increased intra-abdominal pressure with adverse physiologic consequences. Abdominal compartment syndrome caused by perforated peptic ulcer is rare owing to early diagnosis and management. Delayed recognition of perforated peptic ulcer with pneumoperitoneum, bowel distension, and decreased abdominal wall compliance can make up a vicious circle and lead to ACS. We report a case of perforated peptic ulcer associated with ACS. A 74-year-old man with old stroke and dementia history was found to have distended abdomen, edema of bilateral legs, and cyanosis. Laboratory tests revealed deterioration of liver and kidney function. Abdominal compartment syndrome was suspected, and image study was arranged to find the cause. The study showed pneumoperitoneum, contrast stasis in heart with decreased caliber of vessels below the abdominal aortic level, and diffuse lymphedema at the abdominal walls. Emergent laparotomy was performed. Perforated peptic ulcer was noted and the gastrorrhaphy was done. The symptoms, and liver and kidney function improved right after emergent operation.

  18. Perforated peptic ulcer in an infant.

    Science.gov (United States)

    Feng, C Y; Hsu, W M; Chen, Y

    2001-02-01

    We describe a case of perforated peptic ulcer (PPU) in a 9-month-old boy. Abdominal distension was the first clinical sign of PPU. Before he developed abdominal distension, the patient had suffered from an upper respiratory tract infection with fever for about 2 weeks, which was treated intermittently with ibuprofen. A plain abdominal radiograph revealed pneumoperitoneum with a football sign. At laparotomy, a 0.8-cm perforated hole was found over the prepyloric area. Simple closure with omental patching was performed after debridement of the perforation. Pathologic examination showed chronic peptic ulcer with Helicobacter pylori infection. The postoperative course and outcome were satisfactory. The stress of underlying disease, use of ibuprofen, blood type (A), and H. pylori infection might have contributed to the development of PPU in this patient. PPU in infancy is rare and has a high mortality rate; early recognition and prompt surgical intervention are key to successful management.

  19. Neutron absorbed dose in a pacemaker CMOS

    International Nuclear Information System (INIS)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R.; Paredes G, L.

    2012-01-01

    The neutron spectrum and the absorbed dose in a Complementary Metal Oxide Semiconductor (CMOS), has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes an oncology patient that must be treated in a linear accelerator. Pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. Above 7 MV therapeutic beam is contaminated with photoneutrons that could damage the CMOS. Here, the neutron spectrum and the absorbed dose in a CMOS cell was calculated, also the spectra were calculated in two point-like detectors in the room. Neutron spectrum in the CMOS cell shows a small peak between 0.1 to 1 MeV and a larger peak in the thermal region, joined by epithermal neutrons, same features were observed in the point-like detectors. The absorbed dose in the CMOS was 1.522 x 10 -17 Gy per neutron emitted by the source. (Author)

  20. Neutron absorbed dose in a pacemaker CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Paredes G, L., E-mail: fermineutron@yahoo.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2012-06-15

    The neutron spectrum and the absorbed dose in a Complementary Metal Oxide Semiconductor (CMOS), has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes an oncology patient that must be treated in a linear accelerator. Pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. Above 7 MV therapeutic beam is contaminated with photoneutrons that could damage the CMOS. Here, the neutron spectrum and the absorbed dose in a CMOS cell was calculated, also the spectra were calculated in two point-like detectors in the room. Neutron spectrum in the CMOS cell shows a small peak between 0.1 to 1 MeV and a larger peak in the thermal region, joined by epithermal neutrons, same features were observed in the point-like detectors. The absorbed dose in the CMOS was 1.522 x 10{sup -17} Gy per neutron emitted by the source. (Author)

  1. A case report of esophageal perforation: Complication of nasogastric tube placement

    Science.gov (United States)

    Isik, Arda; Firat, Deniz; Peker, Kemal; Sayar, Ilyas; Idiz, Oguz; Soytürk, Mehmet

    2014-01-01

    Patient: Male, 70 Final Diagnosis: Esophageal perforation Symptoms: Abdominal pain • nausea • vomiting Medication: — Clinical Procedure: — Specialty: Surgery Objective: Unusual clinical course Background: Esophageal perforation is a well-defined and severe clinical condition. There are several etiologies of esophagus perforation. Case Report: We report the case of a 70-year-old Caucasian man who underwent an emergency cholecystectomy due to acute cholecystitis. Two days after surgery, his condition deteriorated. Thorax computerized tomography revealed an esophageal perforation. Conclusions: Esophageal perforation due to nasogastric application is relatively rare but the consequences are potentially serious. The anatomy of the upper gastrointestinal system should be understood by all healthcare professionals involved in the treatment. PMID:24803977

  2. Low-energy plasma-cathode electron gun with a perforated emission electrode

    Science.gov (United States)

    Burdovitsin, Victor; Kazakov, Andrey; Medovnik, Alexander; Oks, Efim; Tyunkov, Andrey

    2017-11-01

    We describe research of influence of the geometric parameters of perforated electrode on emission parameters of a plasma cathode electron gun generating continuous electron beams at gas pressure 5-6 Pa. It is shown, that the emission current increases with increasing the hole diameters and decreasing the thickness of the perforated emission electrode. Plasma-cathode gun with perforated electron can provide electron extraction with an efficiency of up to 72 %. It is shown, that the current-voltage characteristic of the electron gun with a perforated emission electrode differs from that of similar guns with fine mesh grid electrode. The plasma-cathode electron gun with perforated emission electrode is used for electron beam welding and sintering.

  3. Transmutation doping of semiconductors by charged particles (review)

    International Nuclear Information System (INIS)

    Kozlovskii, V.V.; Zakharenkov, L.F.; Shustrov, B.A.

    1992-01-01

    A review is given of the state of the art in one of the current topics in radiation doping of semiconductors, which is process of nuclear transmutation doping (NTD) charged particles. In contrast to the neutron and photonuclear transmutation doping, which have been dealt with in monographs and reviews, NTD caused by the action of charged particles is a subject growing very rapidly in the last 10-15 years, but still lacking systematic accounts. The review consists of three sections. The first section deals with the characteristics of nuclear reactions in semiconductors caused by the action of charged particles: the main stress is on the modeling of NTD processes in semiconductors under the action of charged particles. An analysis is made of the modeling intended to give the total numbers of donors and acceptor impurities introduced by the NTD process, to optimize the compensation coefficients, and to estimate the distributions of the dopants with depth in a semiconductor crystal. In the second section the state of the art of experimental investigations of NTD under the influence of charged particles is considered. In view of the specific objects that have been investigated experimntally, the second section is divided into three subsections: silicon, III-V compounds, other semiconductors and related materials (such as high-temperature superconductors, ferroelectric films, etc.). An analysis is made of the communications reporting experimental data on the total numbers of dopants which are introduced, concentration of the electrically active fraction of the impurity, profiles of the dopant distributions, and conditions for efficient annealing of radiation defects. The third section deals with the suitability of NTD by charged particles for the fabrication of semiconductor devices. 45 refs

  4. Perforate on CHO cell membranes induced by electromagnetic ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-06-17

    Jun 17, 2009 ... Key words: Electromagnetic pulse (EMP), atomic force microscope, CHO cell, cell membrane. INTRODUCTION .... of perforation ranges from 390 to 660 nm and the depth is. 392.95 nm. ... cell membrane perforations increased when both the field intensity and ..... Melatonin and a spin-trap compound block.

  5. Perforated appendicitis: Risk factors and outcomes of management ...

    African Journals Online (AJOL)

    The case files of patients with perforated appendicitis were analysed in relation to age, sex, clinical presentation, management and outcome of management. The aim was to detect the main factors that contributed to the perforation of the appendix in these patients and assess the effectiveness of the treatment offered.

  6. Color Doppler Ultrasonography-Targeted Perforator Mapping and Angiosome-Based Flap Reconstruction

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Tei, Troels; Thomsen, Jørn Bo

    2016-01-01

    Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap reconstr......Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap...

  7. Optimizing time management after perforation by colonoscopy results in better outcome for the patients.

    Science.gov (United States)

    Rumstadt, Bernhard; Schilling, Dieter

    2008-01-01

    Perforation during colonoscopy is a rare but severe complication. The aim of this study was to assess the time management and laparoscopic therapy of this complication and to evaluate patient outcomes. A retrospective analysis was done on 15 patients operated for a perforation from colonoscopy between January 2000 and December 2006. Three perforations occurred during diagnostic and 12 perforations during interventional colonoscopy. Two perforations occurred as transmural thermal injury to the colon wall. Peritonitis was found in 4 cases and significantly correlated with the mean time between perforation and operation. Twelve perforations were oversewn laparoscopically and 3 perforations were oversewn by laparotomy. After laparoscopic treatment, hospital stay was significantly shorter than after laparotomy. One patient had a postoperative wound infection, mortality was 0%. Laparoscopic oversewing is a safe and effective method in the treatment of perforation from colonoscopy. Optimizing the time range between perforation and laparoscopic therapy results in a better outcome for the patients.

  8. Bladder perforations in children

    African Journals Online (AJOL)

    2014-11-20

    Nov 20, 2014 ... Mean recovery time for patients was 15 days. ... fracture.[1,2] Isolated bladder perforations are rare, and they .... PA, perineal injury, pelvic fracture. Trauma .... Lower genitourinary injury and pelvic fractures in pediatric patients.

  9. Traumatic oesophageal perforation due to haematoma

    DEFF Research Database (Denmark)

    Grønhøj Larsen, Christian; Brandt, Bodil

    2014-01-01

    . Three explanations postulated to be the cause for late perforation which might be due to esophageal wall ischemia from pressure built up between the hematoma, azygos vein and the lower part of thoracic trachea; or could be an immediate rupture walled-off until the patient became symptomatic......; or the intramural hematoma gradually lysed and causing late perforation. CONCLUSION: Although extremely rare, an oesophageal haematoma and late complications must be considered in patients on anti-coagulant therapy following blunt thoracic trauma and complaining only of chest pain....

  10. Perforation of the Esophagus Secondary to Insertion of Covered Wallstent Endoprostheses

    International Nuclear Information System (INIS)

    Farrugia, Mark; Morgan, Robert A.; Latham, Jennifer A.; Glynos, Michael; Mason, Robert C.; Adam, Andreas

    1997-01-01

    Perforation of the esophagus is a very rare complication of metallic esophageal stent insertion. Two cases are presented in which esophageal perforations were caused by the sharp ends of metallic stents impinging on the esophageal wall. In retrospect, both perforations might have been prevented by additional stent insertion

  11. The US findings of acute nonperforated and perforated appendicitis in children

    International Nuclear Information System (INIS)

    Bae, Jun Gi; Lee, Young Seok; Jung, Yoon Ho; Kim, Ji Hye; Lee, Woon Ki; Lee, Tae Hoon

    1996-01-01

    To analyse and interpret different sonographic findings in acute nonperforated and appendicitis. In 46 cases of acute appendicitis in children(26 girls, 20 boys) proven by surgery, sonographic findings were reviewed retrospectively. The findings of nonperforated and perforated appendicitis were analysed, focusing on the size, shape and echogenicity of the appendix, echo patterns of periappendiceal abscesses, mesenteric lymphadenopathy, and the prevalence of appendicolith. A noncompressible distended appendix was present in 18 of 21 patients with nonperforated appendicitis and in 13 of 25 patients with perforation. In 18 patients with nonperforated appendicitis, the average diameter of distended appendix was 8.6 mm ; target appearance was noted in 16 patients and loss of echogenic submucosa in two. In 13 patients with perforated appendicitis, the average diameter of appendix was 9.1 mm ; target appearance was noted in four patients and loss of echogenic submucosa in nine. Periappendiceal abscesses were present in 21 of 25 cases of perforated appendicitis, and the echogenicity of abscesses was mixed in 12 patients, hypoechogenic in eight, and hyperechogenic in one. Mesenteric lymphadenopathy was present in two of 21 patients with nonperforated appendicitis and in four of 25 with perforation. Appendicolith was detected on sonography in three of 25 patients with perforated appendicitis, but was found in seven patients during surgery. One patients with perforated appendicitis also had right side hydronephrosis. Sonographically false-negative results were obtained in six cases. A sonographic examination was useful to differenciate perforated and nonperforated appendicitis in children. Loss of echogenic submucosa in the distended appendix and periappendiceal abscess formation were important findings in diagnosis of perforated appendicitis

  12. Esophageal perforation during or after conformal radiotherapy for esophageal carcinoma

    International Nuclear Information System (INIS)

    Chen Haiyan; Ma Xiumei; Ye Ming; Hou Yanli; Xie Huaying; Bai Yongrui

    2014-01-01

    The aim of this study was to analyze the risk factors and prognosis for patients with esophageal perforation occurring during or after radiotherapy for esophageal carcinoma. We retrospectively analyzed 322 patients with esophageal carcinoma. These patients received radiotherapy for unresectable esophageal tumors, residual tumors after operation, or local recurrence. Of these, 12 had radiotherapy to the esophagus before being admitted, 68 patients had concurrent chemoradiotherapy (CRT), and 18 patients had esophageal perforation after RT (5.8%). Covered self-expandable metallic stents were placed in 11 patients. Two patients continued RT after stenting and control of infection; one of these suffered a new perforation, and the other had a massive hemorrhage. The median overall survival was 2 months (0-3 months) compared with 17 months in the non-perforation group. In univariate analysis, the Karnofsky performance status (KPS) being ≤ 70, age younger than 60, T4 stage, a second course of radiotherapy to the esophagus, extracapsular lymph nodes (LN) involving the esophagus, a total dose > 100 Gy (biologically effective dose -10 ), and CRT were risk factors for perforation. In multivariate analysis, age younger than 60, extracapsular LN involving the esophagus, T4 stage, and a second course of radiotherapy to the esophagus were risk factors. In conclusion, patients with T4 stage, extracapsular LN involving the esophagus, and those receiving a second course of RT should be given particular care to avoid perforation. The prognosis after perforation was poor. (author)

  13. Magnetic excitations in intermediate valence semiconductors with singlet ground state

    International Nuclear Information System (INIS)

    Kikoin, K.A.; Mishchenko, A.S.

    1994-01-01

    The explanation of the origin inelastic peaks in magnetic neutron scattering spectra of the mixed-valent semiconductor SmB 6 is proposed. It is shown that the excitonic theory of intermediate valence state not only gives the value of the peak frequency but also explains the unusual angular dependence of intensity of inelastic magnetic scattering and describes the dispersion of magnetic excitations in good agreement with experiment

  14. A CLINICAL STUDY ON PATIENTS WITH DUODENAL ULCER PERFORATION

    Directory of Open Access Journals (Sweden)

    Kishore Babu

    2016-03-01

    Full Text Available INTRODUCTION Perforated duodenal ulcer, the most catastrophic complication was Associated with high mortality in the past due to late presentation of the patients, delay in surgery and lack of antibiotics. Various authors state that the incidence of peptic ulcer disease and perforation has been declining for the past 3 decades. Because of advances in the medical therapy of peptic ulcer with a wide range of drugs the management of peptic ulcer disease has been changing and the role of surgery has been declining. Perforation is usually seen in 3rd and 4th decades with a male preponderance and the epidemiological trend is not the same worldwide. Incidence is slightly declining in western countries. The present study has been done during the period between 2013 and 2014 in S. V. R. R. Government general hospital Tirupati. AIMS AND OBJECTIVES The aim of the present study is to analyze the probable factors for increase in incidence of duodenal ulcer perforation, with particular emphasis on assessment of impact of H2 receptor antagonists and Proton Pump inhibitors on the incidence of perforation. STUDY SETTING S. V. Medical College, Department of General Surgery, Tirupati. STUDY PERIOD Patients attending S. V. Medical College, Department of General Surgery with perforation during the period from November 2013 to October 2014. INCLUSION CRITERIA Patients between age group of more than 14 years presenting with pain abdomen and who are diagnosed to have peritonitis due to duodenal ulcer perforation. EXCLUSION CRITERIA Patients with peritonitis due causes other than duodenal ulcer. STUDY METHOD Prospective Observational study among the selected patients. Total numbers of peptic ulcer cases that were admitted in this hospital and treated either medically or surgically were noted. The details of their clinical history and findings, investigation reports, operative findings, post-operative complications were recorded. Simple closure was performed for all the

  15. Jejunal perforation by swallowed ibuprofen caplet | Njoku | Nigerian ...

    African Journals Online (AJOL)

    We present a case of jejunal perforation caused by an unusual foreign body, an ibuprofen caplet in its blister packing believed to be the first of its kind, perforation of the intestine caused by an ingested medication. The patient eventually developed an enterocutaneous fistula through the weak wall of a preexisting incisional ...

  16. Silicon Photo-Multiplier Radiation Hardness Tests with a White Neutron Beam

    International Nuclear Information System (INIS)

    Montanari, A.; Tosi, N.; Pietropaolo, A.; Andreotti, M.; Baldini, W.; Calabrese, R.; Cibinetto, G.; Luppi, E.; Cotta Ramusino, A.; Malaguti, R.; Santoro, V.; Tellarini, G.; Tomassetti, L.; De Donato, C.; Reali, E.

    2013-06-01

    We report radiation hardness tests performed, with a white neutron beam, at the Geel Electron Linear Accelerator in Belgium on silicon Photo-Multipliers. These are semiconductor photon detectors made of a square matrix of Geiger-Mode Avalanche photo-diodes on a silicon substrate. Several samples from different manufacturers have been irradiated integrating up to about 6.2 x 10 9 1-MeV-equivalent neutrons per cm 2 . (authors)

  17. Cause rare d'une perforation de la cloison nasale

    Science.gov (United States)

    Jahidi, Ali; Hemmaoui, Bouchaïb; Itoua, Wulfran Rosaire; Errami, Noureddine; Benariba, Fouad

    2014-01-01

    Les perforations de la cloison nasale constituent une pathologie fréquente en ORL. Leurs causes sont multiples et restent dominées par les traumatismes chirurgicaux. Les étiologies infectieuses et notamment la tuberculose sont rares. Nous présentons le cas d'une patiente ayant bénéficié d'une méatotomie bilatérale et chez laquelle une perforation de la cloison nasale a été découverte lors d'un examen systématique à un an de son intervention. D'abord considérée comme une complication de la chirurgie, la biopsie des berges de la perforation a permis de déterminer son origine tuberculeuse. La présentation clinique des perforations de la cloison nasale n'est pas spécifique. Elles sont souvent asymptomatiques et de découverte fortuite. Les traumatismes notamment chirurgicaux sont le plus siuvent en cause. L′orogine tuberculeuse resta très rare. Le diagnostic de certitude de tuberculose repose sur la biopsie des berges de cette perforation. Le but de ce travail est de mettre en avant l'intérêt de la biopsie dans le diagnostic de la tuberculose de la cloison nasale. Cette biopsie doit être systématique même en cas d'antécédents de chirurgie endonasale qui est le plus souvent en cause dans les perforations de la cloison nasale. PMID:24932334

  18. Reconstruction of pressure sores with perforator-based propeller flaps.

    Science.gov (United States)

    Jakubietz, Rafael G; Jakubietz, Danni F; Zahn, Robert; Schmidt, Karsten; Meffert, Rainer H; Jakubietz, Michael G

    2011-03-01

    Perforator flaps have been successfully used for reconstruction of pressure sores. Although V-Y advancement flaps approximate debrided wound edges, perforator-based propeller flaps allow rotation of healthy tissue into the defect. Perforator-based propeller flaps were planned in 13 patients. Seven pressure sores were over the sacrum, five over the ischial tuberosity, and one on the tip of the scapula. Three patients were paraplegic, six were bedridden, and five were ambulatory. In three patients, no perforators were found. In 10 patients, propeller flaps were transferred. In two patients, total flap necrosis occurred, which was reconstructed with local advancement flaps. In two cases, a wound dehiscence occurred and had to be revised. One hematoma required evacuation. No further complications were noted. No recurrence at the flap site occurred. Local perforator flaps allow closure of pressure sores without harvesting muscle. The propeller version has the added benefit of transferring tissue from a distant site, avoiding reapproximation of original wound edges. Twisting of the pedicle may cause torsion and venous obstruction. This can be avoided by dissecting a pedicle of at least 3 cm. Propeller flaps are a safe option for soft tissue reconstruction of pressure sores. © Thieme Medical Publishers.

  19. Small bowel perforation due to fish bone: A case report

    Directory of Open Access Journals (Sweden)

    Huseyin Pulat

    2015-09-01

    Full Text Available Accidental ingestion of foreign bodies are a common condition in clinical practice. However, small bowel perforation which dues to ingestion foreign bodies has been rarely seen. In this article, we report a case of small bowel perforation which dues to ingestion foreign body. A 80-year-old female patient, presenting with complaints of acute abdomen, was admitted to the emergency department. She denied abdominal pain, nausea and vomiting. The patient had tenderness and defense on the right lower quadrant. Contrast enhanced abdominal computed tomography has been used on the patient's diagnosis. This revealed small bowel perforation due to the ingestion of foreign body. The patient was operated emergency. A microperforation due to fish bone was detected on the terminal ileum. The patient underwent debridement and primary repair. The patient was discharged postoperative 7th day without problem. Bowel perforation due to the ingestion of foreign bodies should be considered in the differential diagnosis of acute abdomen. Keywords: Foreign body, Small intestine, Perforation

  20. Damage induced in semiconductors by swift heavy ion irradiation

    International Nuclear Information System (INIS)

    Levalois, M.; Marie, P.

    1999-01-01

    The behaviour of semiconductors under swift heavy ion irradiation is different from that of metals or insulators: no spectacular effect induced by the inelastic energy loss has been reported in these materials. We present here a review of irradiation effects in the usual semiconductors (silicon, germanium and gallium arsenide). The damage is investigated by means of electrical measurements. The usual mechanisms of point defect creation can account for the experimental results. Besides, some results obtained on the wide gap semiconductor silicon carbide are reported. Concerning the irradiation effects induced by heavy ions in particle detectors, based on silicon substrate, we show that the deterioration of the detector performances can be explained from the knowledge of the substrate properties which are strongly perturbed after high doses of irradiation. Finally, some future ways of investigation are proposed. The silicon substrate is a good example to compare the irradiation effects with different particles such as electrons, neutrons and heavy ions. It is then necessary to use parameters which account for the local energy deposition, in order to describe the damage in the material

  1. Perforated Duodenal Ulcer in a Young Child: An Uncommon Condition

    Directory of Open Access Journals (Sweden)

    Rohit Prasad Yadav

    2009-04-01

    Full Text Available Duodenal ulcer is an uncommonly diagnosed entity in children. H. pyloriinfection, blood group ‘O’ or secondary to medications like non steroidal anti-infl ammatory drugs (NSAID and corticosteroids or physiological stress in burns, head injury and mucosal ischemia are implicated as risk factors for their causation. The diagnosis is usually overlooked because of vague and variable symptoms and remote index of suspicion accounted for their low incidence in children. Undiagnosed or mistreated perforations may carry high morbidity and mortality. We report a successfully treated 41/2 year old male child who presented with features of perforation peritonitis and was incidentally found to have a perforated duodenal ulcer. Key Words: duodenal ulcer, laparotomy, perforation

  2. Perforated choledochal cyst in a Jehovah's Witness patient.

    Science.gov (United States)

    Jones, V S; Philip, C

    2007-07-01

    Perforation is a rare presentation of a choledochal cyst. The case reported is a 9-month-old female baby with a perforated choledochal cyst. Being a Jehovah's Witness, blood tranfusion was refused. Apart from highlighting this social dilemma, the suitability of a cystojejunostomy as a temporary measure in the above scenario is evaluated and discussed.

  3. Gastric Perforation by Ingested Rabbit Bone Fragment

    Directory of Open Access Journals (Sweden)

    Giulio Gambaracci

    2016-04-01

    Full Text Available The majority of accidentally ingested foreign bodies is excreted from the gastrointestinal (GI tract without any complications. Sometimes sharp foreign bodies – like chicken and fish bones – can lead to intestinal perforation and may present insidiously with a wide range of symptoms and, consequently, different diagnoses. We report the case of a 59-year-old woman presenting with fever and a 1-month history of vague abdominal pain. Computed tomography (CT showed the presence of a hyperdense linear image close to the gastric antrum surrounded by a fluid collection and free peritoneal air. At laparotomy, a 4-cm rabbit bone fragment covered in inflamed tissue was detected next to a gastric wall perforation. Rabbit bone fragment ingestion, even if rarely reported, should not be underestimated as a possible cause of GI tract perforation.

  4. A rare manifestation of perforated diverticulitis: parastomal subcutaneous abscess.

    NARCIS (Netherlands)

    Peters, J.H.; Bleichrodt, R.P.; Goor, H. van

    2003-01-01

    Perforation is a serious complication of diverticular disease. The sigmoid is the main affected anatomic site of perforated diverticulitis and sigmoid resection followed either by Hartmann procedure or primary anastomosis are the standard surgical approaches. Surgery, however, does not cure

  5. Study on modal characteristics of perforated shell using effective Young's modulus

    International Nuclear Information System (INIS)

    Jhung, Myung Jo; Yu, Seon Oh

    2011-01-01

    Research highlights: → The effective Young's modulus of perforated shell is proposed for modal analysis. → The penetration pattern is almost negligible for effective elastic constants. → The frequency of perforated shell decreases significantly due to the hole effect. - Abstract: For the perforated cylindrical shell submerged in fluid, it is almost impossible to develop a finite element model due to the necessity of the fine meshing of the shell and the fluid at the same time. This necessitates the use of solid shell with effective material properties. Unfortunately the effective elastic constants are not found in any references even though the ASME code is suggesting those for perforated plate. Therefore in this study the effective material properties of perforated shell are suggested by performing several finite element analyses with respect to the ligament efficiencies.

  6. Delayed Diagnosis of Pharyngeal Perforation following Exploding Tyre Blast Barotrauma

    Directory of Open Access Journals (Sweden)

    Samantha M. Field

    2014-01-01

    Full Text Available Introduction. Pharyngoesophageal perforation secondary to barotrauma is a rare phenomenon that can have serious complications if identified late. It is challenging to detect due to nonspecific symptoms. We present a case in which detection proved difficult leading to delayed diagnosis. Case Report. A 27-year-old mechanic presented with haemoptysis, dysphonia, and odynophagia after a car tyre exploded in his face. Flexible nasoendoscopy (FNE revealed blood in the pharynx, thought to represent mucosal haemorrhage. Initial treatment consisted of IV dexamethasone and antibiotics. After 3 days, odynophagia persisted prompting a CT scan. This revealed a defect in the posterior hypopharynx and surgical emphysema in the deep neck tissues. Contrast swallow confirmed posterior hypopharyngeal leak. NG feeding was commenced until repeated contrast swallow confirmed resolution of the defect. Discussion. Prompt nonsurgical management of pharyngoesophageal perforation has good outcomes but untreated perforation can have serious complications. FNE should be performed routinely, but only a contrast swallow can diagnose a functional perforation. Clinicians should have a high index of clinical suspicion when patients present with barotrauma and odynophagia. Patients should be kept nil by mouth until perforation has been excluded. Conclusion. When faced with cases of facial barotrauma, clinicians should have a low threshold for further imaging to exclude pharyngoesophageal perforation.

  7. Laparoscopic lavage for perforated diverticulitis with purulent peritonitis

    DEFF Research Database (Denmark)

    Thornell, Anders; Angenete, Eva; Bisgaard, Thue

    2016-01-01

    Background: Perforated diverticulitis with purulent peritonitis has traditionally been treated with open colon resection and stoma formation with risk for reoperations, morbidity, and mortality. Laparoscopic lavage alone has been suggested as definitive treatment. Objective: To compare laparoscopic...... lavage with open colon resection and colostomy (Hartmann procedure) for perforated diverticulitis with purulent peritonitis. Design: Randomized, controlled, multicenter, open-label trial. (ISRCTN registry number: ISRCTN82208287) Setting: 9 hospitals in Sweden and Denmark. Patients: Patients who have...... confirmed Hinchey grade III perforated diverticulitis with purulent peritonitis at diagnostic laparoscopy. Intervention: Randomization between laparoscopic lavage and the Hartmann procedure. Measurements: Primary outcome was the percentage of patients having 1 or more reoperations within 12 months. Key...

  8. Transmural coil embolization—alternative technique for management of arterial perforation during subintimal angioplasty

    Directory of Open Access Journals (Sweden)

    Karthikeyan Damodharan

    2016-01-01

    Full Text Available Subintimal angioplasty of lower limb arterial occlusion carries a relatively higher risk of vessel perforation compared to transluminal angioplasty. Vessel perforation is a potentially life threatening complication which requires prompt recognition and management. They are usually managed by endovascular techniques such as low-pressure balloon tamponade, covered stents, and coil embolization of the ruptured artery. We describe a technique of treating vessel perforation following balloon angioplasty. Patient developed a large perforation of the proximal superficial femoral artery (SFA after balloon inflation during subintimal angioplasty of complete SFA occlusion. Following failure of balloon tamponade in sealing the perforation, we successfully treated it by deploying an embolization coil at the site of perforation through the vessel wall followed by balloon tamponade. Our technique could be a useful relatively inexpensive alternative treatment option in the management of vessel perforation compared to covered stents.

  9. External perforated Solar Screens for daylighting in residential desert buildings: Identification of minimum perforation percentages

    KAUST Repository

    Sherif, Ahmed

    2012-06-01

    The desert climate is endowed by clear sky conditions, providing an excellent opportunity for optimum utilization of natural light in daylighting building indoor spaces. However, the sunny conditions of the desert skies, in countries like Egypt and Saudi Arabia, result in the admittance of direct solar radiation, which leads to thermal discomfort and the incidence of undesired glare. One type of shading systems that is used to permit daylight while controlling solar penetration is " Solar Screens" Very little research work addressed different design aspects of external Solar Screens and their influence on daylighting performance, especially in desert conditions, although these screens proved their effectiveness in controlling solar radiation in traditional buildings throughout history.This paper reports on the outcomes of an investigation that studied the influence of perforation percentage of Solar Screens on daylighting performance in a typical residential living room of a building in a desert location. The objective was to identify minimum perforation percentage of screen openings that provides adequate illuminance levels in design-specific cases and all-year-round.Research work was divided into three stages. Stage one focused on the analysis of daylighting illuminance levels in specific dates and times, while the second stage was built on the results of the first stage, and addressed year round performance using Dynamic Daylight Performance Metrics (DDPMs). The third stage addressed the possibility of incidence of glare in specific cases where illuminance levels where found very high in some specific points during the analysis of first stage. The research examined the daylighting performance in an indoor space with a number of assumed fixed experimentation parameters that were chosen to represent the principal features of a typical residential living room located in a desert environment setting.Stage one experiments demonstrated that the screens fulfilled the

  10. Spectrum of perforation peritonitis in Pakistan: 300 cases Eastern experience

    OpenAIRE

    Ur-Rahman Shafiq; Malik Faiza; Afridi Shahida; Shamim Shahid; Samo Khursheed A

    2008-01-01

    Abstract Background Perforation peritonitis is the most common surgical emergency encountered by the surgeons all over the world as well in Pakistan. The spectrum of etiology of perforation peritonitis in tropical countries continues to differ from its western counter part. This study was conducted at Dow University of health sciences and Civil Hospital Karachi (DUHS & CHK) Pakistan, designed to highlight the spectrum of perforation peritonitis in the East and to improve its outcome. Methods ...

  11. CLINICAL STUDY OF APPENDICULAR PERFORATION IN A TERTIARY CARE HOSPITAL

    Directory of Open Access Journals (Sweden)

    Venkata Anantha Lakshmi Manabala

    2016-06-01

    Full Text Available INTRODUCTION Acute Appendicitis is the commonest abdominal surgical emergency in young adults all over the world. In early 1900s, Ochsner in Chicago and Sherren at the London Hospital were both advocates of conservative treatment in late cases. Appendicular perforation is a serious complication in view of the ensuing peritonitis with the consequent sequelae and morbidity. AIM To study the incidence, morbidity and sequelae of appendicular perforation. MATERIALS & METHODS This is a prospective study done in our hospital where 110 cases of peritonitis due to appendicular perforation were selected for our study. All the cases where peritonitis was due to appendicular perforation at laparotomy were included. The study period was from January 2014 to December 2015. The cases of peritonitis due to other causes like duodenal, gastric, enteric perforation were excluded. Patients with acute abdominal emergency with clinical diagnosis of peritonitis were examined carefully with detailed history and clinical examination. Necessary investigations were done and patients taken up for emergency surgery. CONCLUSIONS Acute Appendicitis is the commonest abdominal surgical emergency in young adults all over the world. Age incidence of appendicular perforation is maximum in the age group of 21–30 years. Next common age group is 31–40 yrs. Incidence is more in males. Male to female ratio is 2.4:1. Pain abdomen, vomiting, fever and anorexia were common symptoms in all the patients. Majority of the patients came late to the hospital accounting for the cause of perforation and subsequent mortality and morbidity.

  12. The research progress of acute small bowel perforation

    Directory of Open Access Journals (Sweden)

    Rudolf Schiessel

    2015-08-01

    Full Text Available This article reviews the various aetiologies of small bowel perforations and their management. In addition to the well-known aetiologies such as trauma, inflammation and circulatory disorders, several new causes of small bowel perforation have been described in recent years. The spectrum reaches from iatrogenic perforations during laparoscopic surgery or enteroscopies to drug-induced perforations with new anticancer agents. The management of small bowel perforations requires a concept consisting of the safe revision of the leaking bowel and the treatment of the peritonitis. Depending on the local situation and the condition of the patient, several treatment options are available. The surgical management of the bowel leak can range from a simple primary closure to a delayed restoration of bowel continuity. When the condition of the bowel or patient is frail, the risk of a failure of a closure or anastomosis is too high, and the exteriorization of the bowel defect as a primary measure is a safe option. The treatment of the peritonitis is also dependent on the condition of the patient and the local situation. Early stages of peritonitis can be treated by a simple peritoneal lavage, either performed by laparoscopy or laparotomy. Severe forms of peritonitis with multi-organ failure and an abdominal compartment syndrome need repeated peritoneal revisions. In such cases, the abdomen can only be closed temporarily. Different technical options are available in order to overcome the difficult care of these patients.

  13. Analysis of colonoscopic perforations at a local clinic and a tertiary hospital.

    Science.gov (United States)

    Sagawa, Toshihiko; Kakizaki, Satoru; Iizuka, Haruhisa; Onozato, Yasuhiro; Sohara, Naondo; Okamura, Shinichi; Mori, Masatomo

    2012-09-21

    To define the clinical characteristics, and to assess the management of colonoscopic complications at a local clinic. A retrospective review of the medical records was performed for the patients with iatrogenic colon perforations after endoscopy at a local clinic between April 2006 and December 2010. Data obtained from a tertiary hospital in the same region were also analyzed. The underlying conditions, clinical presentations, perforation locations, treatment types (operative or conservative) and outcome data for patients at the local clinic and the tertiary hospital were compared. A total of 10  826 colonoscopies, and 2625 therapeutic procedures were performed at a local clinic and 32  148 colonoscopies, and 7787 therapeutic procedures were performed at the tertiary hospital. The clinic had no perforations during diagnostic colonoscopy and 8 (0.3%) perforations were determined to be related to therapeutic procedures. The perforation rates in each therapeutic procedure were 0.06% (1/1609) in polypectomy, 0.2% (2/885) in endoscopic mucosal resection (EMR), and 3.8% (5/131) in endoscopic submucosal dissection (ESD). Perforation rates for ESD were significantly higher than those for polypectomy or EMR (P hospital. Six perforations occurred with therapeutic endoscopy (perforation rate, 0.08%; 1 per 1298 procedures). Perforation rates for specific procedure types were 0.02% (1 per 5500) for polypectomy, 0.17% (1 per 561) for EMR, 2.3% (1 per 43) for ESD in the tertiary hospital. There were no differences in the perforation rates for each therapeutic procedure between the clinic and the tertiary hospital. The incidence of iatrogenic perforation requiring surgical treatment was quite low in both the clinic and the tertiary hospital. No procedure-related mortalities occurred. Performing closure with endoscopic clipping reduced the C-reactive protein (CRP) titers. The mean maximum CRP titer was 2.9 ± 1.6 mg/dL with clipping and 9.7 ± 6.2 mg/dL without clipping

  14. Perforated peptic ulcer in southeastern Taiwan.

    Science.gov (United States)

    Li, Chin-Hsien; Chang, Wen-Hsiung; Shih, Shou-Chuan; Lin, Shee-Chan; Bair, Ming-Jong

    2010-09-01

    No studies focus on the population with perforated peptic ulcer in southeastern Taiwan. The present study aimed to assess the differences between the different races and the risk factors related to mortality and morbidity in postoperative patients in southeastern Taiwan. The medical records of 237 patients were reviewed retrospectively. The following factors were analyzed: patient profiles, coexisting illnesses, diagnostic method, fever, preoperative shock, clinical data at emergency room, delay operation, site of perforation, operative method, positive ascites culture, species of microbes in ascites culture, postoperative complications, death and the length of hospital stay. Aborigines were significantly different from non-aborigines in the ratio of female cases and in the habits of alcohol drinking and betel nut chewing. There were also four significantly different variables between them: fever, hemoglobin value, site of perforation and operative method. Total postoperative complication rate was 41.3% and 39 patients (16.6%) died. In multivariate analysis, age > or = 65 years, lipase > upper normal limit and preoperative shock were independent predictors of mortality. Significant risk factors associated with morbidity were NSAIDs use, creatinine > 1.5 mg/dL and preoperative shock. Aborigines were different from non-aborigines in several categories. In southeastern Taiwan, NSAIDs use, creatinine > 1.5 mg/dL and preoperative shock were independent risk factors of morbidity, and age > or = 65 years, lipase > upper normal limit and preoperative shock were independent risk factors of mortality in postoperative perforated peptic ulcer. Lipase > upper normal limit is needed for further research on the influence on mortality.

  15. Case report: Stercoral sigmoid colonic perforation with fecal peritonitis

    International Nuclear Information System (INIS)

    Sharma, Monika; Agrawal, Anjali

    2010-01-01

    Chronic constipation can lead to fecal impaction. It can also rarely lead to catastrophic complications like perforation, colonic obstruction, and fecal peritonitis. We report a rare case of stercoral sigmoid colonic perforation with fecal peritonitis and pneumoperitoneum, which was diagnosed on preoperative CT scan

  16. Identification and spectrometry of charged particles produced in reactions induced by 14 MeV neutrons. II

    International Nuclear Information System (INIS)

    Sellem, C.; Perroud, J.P.; Loude, J.F.

    1975-01-01

    A counter telescope consisting of gas proportional counters, a thin semiconductor detector and a thick one has been built and used for the study of the angular differential cross sections of (n, charged particles) reactions induced by 14 MeV neutrons. Detection of the α-particles emitted in the neutron production reaction 3 H(d,n) 4 He gives a time reference for the measurement of the time of flight of the charged particles and allows a precise monitoring of the intensity of the neutron beam. High energy protons, deuterons and tritons are identified by their energy losses in the thin semiconductor detector and in the thick one and by their time of flight. Low energy protons, deuterons, tritons and all α-particles stop in the thin semiconductor detector and are identified by their energy losses in this detector and in one gas proportional counter as well as by their time of flight. It is possible to identify and to measure the energy of all charged particles in the energy range of 2 to 15 MeV: a very low background results from the use of the time of flight. (Auth.)

  17. Generalized multiscale finite element methods for problems in perforated heterogeneous domains

    KAUST Repository

    Chung, Eric T.

    2015-06-08

    Complex processes in perforated domains occur in many real-world applications. These problems are typically characterized by physical processes in domains with multiple scales. Moreover, these problems are intrinsically multiscale and their discretizations can yield very large linear or nonlinear systems. In this paper, we investigate multiscale approaches that attempt to solve such problems on a coarse grid by constructing multiscale basis functions in each coarse grid, where the coarse grid can contain many perforations. In particular, we are interested in cases when there is no scale separation and the perforations can have different sizes. In this regard, we mention some earlier pioneering works, where the authors develop multiscale finite element methods. In our paper, we follow Generalized Multiscale Finite Element Method (GMsFEM) and develop a multiscale procedure where we identify multiscale basis functions in each coarse block using snapshot space and local spectral problems. We show that with a few basis functions in each coarse block, one can approximate the solution, where each coarse block can contain many small inclusions. We apply our general concept to (1) Laplace equation in perforated domains; (2) elasticity equation in perforated domains; and (3) Stokes equations in perforated domains. Numerical results are presented for these problems using two types of heterogeneous perforated domains. The analysis of the proposed methods will be presented elsewhere. © 2015 Taylor & Francis

  18. Colonic perforation with peritonitis in amoebiasis: a tropical disease with high mortality.

    Science.gov (United States)

    Jain, Bhupendra Kumar; Garg, Pankaj Kumar; Kumar, Anjay; Mishra, Kiran; Mohanty, Debajyoti; Agrawal, Vivek

    2013-01-01

    Invasive colonic amoebiasis presents primarily with dysentery; colonic perforation occurs rarely. Cases of amoebic colonic perforations have been reported sporadically over the past 20 years. A retrospective study was done in the surgical unit of a tertiary care hospital in North India. The case records of those patients were reviewed who underwent exploratory laparotomy from January 2011 to September 2012 and were diagnosed with amoebic colonic perforation on histopathological examination. Details concerning the clinical presentation, investigations, intraoperative findings, operative procedures, and postoperative outcomes were retrieved. Amongst, a total of 186 emergency exploratory laparotomies carried out during the study, 15 patients of amoebic colonic perforation were identified. The median age of the patients was 42 years (IQR 32.0-58.0) and the male to female ratio was 13:2. Previous history of colitis was present in only 1 patient. The preoperative diagnosis was perforation peritonitis in 12 patients; and intussusception, intestinal obstruction and ruptured liver abscess in 1 patient each. Ten patients had single perforation while 5 had multiple colonic perforations. All the patients except one had perforations in the right colon. Bowel resection was performed depending upon the site and extent of the colon involved-right hemicolectomy (8), limited ileocolic resection (6) and sigmoidectomy (1). Bowel continuity could be restored only in 2 of the 15 patients and a stoma was constructed in the remaining 13 patients. The overall mortality rate was found to be 40% (6/15). Amoebic colonic perforation is associated with unusually high mortality.

  19. [Laparoscopic surgery for perforated peptic ulcer].

    Science.gov (United States)

    Yasuda, Kazuhiro; Kitano, Seigo

    2004-03-01

    Laparoscopic surgery has become the treatment of choice for the management of perforated peptic ulcer. The advantages of laparoscopic repair for perforated peptic ulcer include less pain, a short hospital stay, and an early return to normal activity. Although the operation time of laparoscopic surgery is significantly longer than that of open surgery, laparoscopic technique is safe, feasible, and with morbidity and mortality comparable to that of the conventional open technique. To benefit from the advantages offered by minimally invasive laparoscopic technique, further study will need to determine whether laparoscopic surgery is safe in patients with generalized peritonitis or sepsis.

  20. Perforated Meckel's diverticulum in omphalocele

    OpenAIRE

    Jin, Hanna; Han, Ji-Won; Oh, Chaeyoun; Kim, Hyun-Young; Jung, Sung-Eun

    2017-01-01

    Meckel's diverticulum is a rare condition in neonates with reports of concurrent Meckel's diverticulum and omphalocele being few. Herein, we present a case of omphalocele associated with perforated Meckel's diverticulum.

  1. Perforated Meckel's diverticulitis complicating active Crohn's ileitis: a case report.

    Science.gov (United States)

    Schwenter, Frank; Gervaz, Pascal; de Saussure, Philippe; McKee, Thomas; Morel, Philippe

    2009-01-13

    In Crohn's disease, the extension of active terminal ileitis into a Meckel's diverticulum is possible, but usually has no impact on clinical decision-making. We describe an original surgical approach in a young woman presenting with a combination of perforated Meckel's diverticulitis and active Crohn's ileitis. We report the case of a 22-year-old woman with Crohn's disease, who was admitted for abdominal pain, fever and diarrhoea. CT scan demonstrated active inflammation of the terminal ileum, as well as a fluid collection in the right iliac fossa, suggesting intestinal perforation. Laparoscopy was performed and revealed, in addition to extensive ileitis, a 3 x 3 cm abscess in connection with perforated Meckel's diverticulitis. It was therefore possible to avoid ileocaecal resection by only performing Meckel's diverticulectomy; pathological examination of the surgical specimen revealed the presence of transmural inflammation with granulomas and perforation of the diverticulum at its extremity. Crohn's disease of the ileum may be responsible for Meckel's diverticulitis and cause perforation which, in this case, proved to be a blessing in disguise and spared the patient an extensive small bowel resection.

  2. Research reactor of the future: The advanced neutron source

    International Nuclear Information System (INIS)

    Appleton, B.; West, C.

    1994-01-01

    Agents for cancer detection and treatment, stronger materials, better electronic gadgets, and other consumer and industrial products - these are assured benefits of a research reactor project proposed for Oak Ridge. Just as American companies have again assumed world leadership in producing semiconductor chips as well as cars and trucks, the United States is poised to retake the lead in neutron science by building and operating the $2.9 billion Advanced Neutron Source (ANS) research reactor by the start of the next century. In 1985, the neutron community, led by ORNL researchers, proposed a pioneering project, later called the ANS. Scheduled to begin operation in 2003, the ANS is seen not only as a replacement for the aging HFIR and HFBR but also as the best laboratory in the world for conducting neutron-based research

  3. A Five-Year Review of Perforated Peptic Ulcer Disease in Irrua, Nigeria.

    Science.gov (United States)

    Dongo, A E; Uhunmwagho, O; Kesieme, E B; Eluehike, S U; Alufohai, E F

    2017-01-01

    Peptic ulcer perforation is a common cause of emergency admission and surgery. This is the first study that documents the presentation and outcome of management in Irrua, Nigeria. This is a prospective study of all patients operated on for perforated peptic ulcer between April 1, 2010, and March 31, 2015. A structured questionnaire containing patients' demographics, operation findings, and outcome was filled upon discharge or death. There were 104 patients. 81 males and 23 females (M : F = 3.5 : 1). The age range was between 17 years and 95 years. The mean age was 48.99 years ± SD 16.1 years. The ratio of gastric to duodenal perforation was 1.88 : 1. Perforation was the first sign of peptic ulcer disease in 62 (59.6%). Pneumoperitoneum was detectable with plain radiographs in 95 (91%) patients. 72 (69.2%) had Graham's Omentopexy. Death rate was 17.3%. We note that gastric perforation is a far commoner disease in our environment. Perforation is often the first sign of peptic ulcer disease. We identify fasting amongst Christians as a risk factor for perforation.

  4. Spontaneous perforation of sigmoid colon in a child with acute lymphoblastic leukemia

    Directory of Open Access Journals (Sweden)

    Miolski Jelena

    2017-01-01

    Full Text Available Introduction. Perforation of the sigmoid colon is rare in children and its descriptions in medical literature are infrequent. Case Outline. In a 13-year-old boy with acute lymphoblastic leukemia, a ten-month course of chemotherapy was accompanied by many complications: parasitic infestation (Enterobius vermicularis, lung candidiasis, esophageal candidiasis, steroid diabetes, anaphylactoid reaction to L-asparaginase, febrile neutropenia, mucositis, anemia, thrombocytopenia, enterocolitis, and respiratory distress syndrome. During reinduction treatment, consisting of dexamethasone, vincristine, doxorubicin, and crisantaspase, he complained of abdominal pain and, upon radiographic examination, was found to have pneumoperitoneum. Because of suspicion of abdominal hollow organ perforation, he was subjected to explorative laparotomy, which yielded the diagnosis of perforation of the sigmoid colon. Conclusion. After an extensive review of the published reports on sigmoid perforation, all associated conditions that could possibly induce perforation – such as Hirschsprung’s disease or foreign body – were systematically excluded in our patient. Although typhlitis was the first diagnostic hypothesis, this was excluded by intraoperative findings, histopathology, and perforation site. To the best of our knowledge, this is the first report of a spontaneous perforation of the sigmoid colon in a child with acute lymphoblastic leukemia.

  5. Laparoscopic management of duodenal ulcer perforation: is it advantageous?

    Science.gov (United States)

    Palanivelu, C; Jani, Kalpesh; Senthilnathan, P

    2007-01-01

    Surgery is the mainstay of treatment of patients with peptic duodenal perforation. With the advent of minimal access techniques, laparoscopy is being used for the treatment of this condition. Retrospective analysis of 120 consecutive patients (mean age 44.5 years; 111 men) with duodenal ulcer perforation who had undergone laparoscopic surgery. 87 patients had history of tobacco consumption, 12 were chronic NSAID users, 72 had Helicobacter pylori infection and 36 had a co-morbid condition. The mean time to surgery from onset of symptoms was 28.4 hours. The median operating time was 46 minutes. All patients underwent laparoscopic closure of the perforation with Graham's patch omentopexy; 12 patients underwent additional definitive ulcer surgery. The morbidity rate was 7.5%; no patient needed conversion to open surgery or died. The mean postoperative hospital stay was 5.8 days. Results of laparoscopic management of perforated peptic ulcer are encouraging, with no conversion to open surgery, low morbidity and no mortality.

  6. Corneal perforation after conductive keratoplasty with previous refractive surgery.

    Science.gov (United States)

    Kymionis, George D; Titze, Patrik; Markomanolakis, Marinos M; Aslanides, Ioannis M; Pallikaris, Ioannis G

    2003-12-01

    A 56-year-old woman had conductive keratoplasty (CK) for residual hyperopia and astigmatism. Three years before the procedure, the patient had arcuate keratotomy, followed by laser in situ keratomileusis 2 years later for high astigmatism correction in both eyes. During CK, a corneal perforation occurred in the right eye; during the postoperative examination, an iris perforation and anterior subcapsule opacification were seen beneath the perforation site. The perforation was managed with a bandage contact lens and an antibiotic-steroid ointment; it had a negative Seidel sign by the third day. The surgery in the left eye was uneventful. Three months after the procedure, the uncorrected visual acuity was 20/32 and the best corrected visual acuity 20/20 in both eyes with a significant improvement in corneal topography. Care must be taken to prevent CK-treated spots from coinciding with areas in the corneal stroma that might have been altered by previous refractive procedures.

  7. Single Event Upset in Static Random Access Memories in Atmospheric Neutron Environments

    Science.gov (United States)

    Arita, Yutaka; Takai, Mikio; Ogawa, Izumi; Kishimoto, Tadafumi

    2003-07-01

    Single-event upsets (SEUs) in a 0.4 μm 4 Mbit complementary metal oxide semiconductor (CMOS) static random access memory (SRAM) were investigated in various atmospheric neutron environments at sea level, at an altitude of 2612 m mountain, at an altitude of commercial airplane, and at an underground depth of 476 m. Neutron-induced SEUs increase with the increase in altitude. For a device with a borophosphosilicate glass (BPSG) film, SEU rates induced by thermal neutrons increase with the decrease in the cell charge of a memory cell. A thermal neutron-induced SEU is significant in SRAMs with a small cell charge. With the conditions of small cell charge, thermal neutron-induced SEUs account for 60% or more of the total neutron-induced SEUs. The SEU rate induced by atmospheric thermal neutrons can be estimated by an acceleration test using 252Cf.

  8. An Experimentally Validated Numerical Modeling Technique for Perforated Plate Heat Exchangers.

    Science.gov (United States)

    White, M J; Nellis, G F; Kelin, S A; Zhu, W; Gianchandani, Y

    2010-11-01

    Cryogenic and high-temperature systems often require compact heat exchangers with a high resistance to axial conduction in order to control the heat transfer induced by axial temperature differences. One attractive design for such applications is a perforated plate heat exchanger that utilizes high conductivity perforated plates to provide the stream-to-stream heat transfer and low conductivity spacers to prevent axial conduction between the perforated plates. This paper presents a numerical model of a perforated plate heat exchanger that accounts for axial conduction, external parasitic heat loads, variable fluid and material properties, and conduction to and from the ends of the heat exchanger. The numerical model is validated by experimentally testing several perforated plate heat exchangers that are fabricated using microelectromechanical systems based manufacturing methods. This type of heat exchanger was investigated for potential use in a cryosurgical probe. One of these heat exchangers included perforated plates with integrated platinum resistance thermometers. These plates provided in situ measurements of the internal temperature distribution in addition to the temperature, pressure, and flow rate measured at the inlet and exit ports of the device. The platinum wires were deposited between the fluid passages on the perforated plate and are used to measure the temperature at the interface between the wall material and the flowing fluid. The experimental testing demonstrates the ability of the numerical model to accurately predict both the overall performance and the internal temperature distribution of perforated plate heat exchangers over a range of geometry and operating conditions. The parameters that were varied include the axial length, temperature range, mass flow rate, and working fluid.

  9. The posterolateral mid-forearm perforator flap: anatomical study and clinical application.

    Science.gov (United States)

    Zhuang, Yue-Hong; Lin, Jian; Fu, Fei-Huan; Cai, Zhen-De; Huang, Hui-Mei; Zheng, He-Ping

    2013-11-01

    Defects sustained at the distal forearm are common and pedicled perforator flaps have unique advantages in resurfacing it. The purpose of this study is to reappraise the anatomy of the perforator in the posterolateral aspect of the mid-forearm and present our clinical experience on using perforator flaps based on it for reconstruction of defects in the distal forearm. This study was divided into anatomical study and clinical application. In the anatomical study, 30 preserved upper limbs were used. Clinically, 11 patients with defects at the forearm underwent reconstruction with the posterolateral mid-forearm perforator flaps. The defects, ranging from 4.5 × 2.5 cm to 10.5 × 4.5 cm, were located at the dorsal aspect of the distal forearm in 6 cases and at the volar aspect of the distal forearm in 5 cases. Three patterns of the perforator were observed in the posterolateral aspect of the mid-forearm, which originated from the posterior interosseous artery, the proximal segment of the radial artery or the radial recurrent artery, and the middle segment of the radial artery, respectively. The perforator was located 11.8 ± 0.2 cm to 15.8 ± 0.4 cm inferior to the lateral humeral epicondyle. Clinically, flaps in 8 cases survived uneventfully, while the other 3 cases suffered mild marginal epidermal necrosis, which was cured with continuous dress changing. The location of the perforator at the posterolateral aspect of the mid-forearm is consistent; the posterolateral mid-forearm perforator flap is particularly suitable to cover defects in the distal one-third of the forearm. Copyright © 2013 Wiley Periodicals, Inc.

  10. Three-dimensional numerical simulation of wave interaction with perforated quasi-ellipse caisson

    Directory of Open Access Journals (Sweden)

    Yong-xue Wang

    2011-03-01

    Full Text Available The finite difference method and the volume of fluid (VOF method were used to develop a three-dimensional numerical model to study wave interaction with a perforated caisson. The partial cell method was adopted to solve this type of problem for the first time. The validity of the present model, with and without the presence of caisson structures, was examined by comparing the model results with experimental data. Then, the numerical model was used to investigate the effects of various wave and structure parameters on the wave force and wave runup of the perforated quasi-ellipse caisson. Compared with the solid quasi-ellipse caisson, the wave force on the perforated quasi-ellipse caisson is significantly reduced with increasing porosity of the perforated quasi-ellipse caisson. Furthermore, the perforated quasi-ellipse caisson can also reduce the wave runup, and it tends to decrease with the increase of the porosity of the perforated quasi-ellipse caisson and the relative wave height.

  11. Peritonitis by jejunal ulcer perforation in a child: a case report

    Directory of Open Access Journals (Sweden)

    Ndèye Aby Ndoye

    2017-01-01

    Full Text Available Ulcer perforation is a rare cause of peritonitis in children. The cases reported in the literature are caused by peptic ulcer. We report on a case of peritonitis caused by jejunal ulcer perforation, discovered in a girl's abdomen during an acute surgical procedure. The treatment consisted of a resection of the perforation followed by an end-to-end anastomosis. Postoperative period was uneventful.

  12. Phototransistor response under a neutron fluence

    International Nuclear Information System (INIS)

    Santos, Luiz A.P.; Barros, Fabio R.; Ursulino, Luciano C.; Silva Junior, Eronides F.; Antonio Filho, Joao

    2009-01-01

    The purpose of this communication is to show some effects on a bipolar phototransistor after it has been under a neutron fluence. Unlike a transistor, a phototransistor is designed so that the collector has a large area and consequently it has a higher radiation detection probability. Then, it is possible to have a certain number of interactions so that any changes in the internal structure of the phototransistor can be observed after a neutron irradiation. If a phototransistor is under a certain spectra of neutron fluence the interaction depends on the cross section of the either silicon chip or its encapsulation, and recoil protons could be the charged particle responsible for changes in the semiconductor structure. Furthermore, neutron irradiation could give to the device a state of vanishing in its electrical characteristic which can be performed tracing the current versus voltage curve (I x V). The experimental arrangement basically consists of a photonic device, a neutron-gamma radiation source and a Flip-Flop electrometer second generation (EFF-2G). One of the main parameters of evaluation was the phototransistor dark current. In fact, the first results demonstrate that when the phototransistor is neutron irradiated there is a significant variation in its I x V characteristic curve. (author)

  13. Single center experience in laparoscopic treatment of gallbladder perforation.

    Science.gov (United States)

    Sahbaz, Nuri Alper; Peker, Kivanc Derya; Kabuli, Hamit Ahmet; Gumusoglu, Alpen Yahya; Alis, Halil

    2017-12-01

    Gallbladder perforation (GBP) is a rare disease with potential mortality. Previous series have reported an incidence of approximately 2-11% and it still continues to be a significant problem for surgeons. To present our clinical experience with gallbladder perforation. The records of 2754 patients who received surgical treatment for cholelithiasis between 2010 and 2016 were reviewed retrospectively. One hundred thirty-three patients had gallbladder perforation. Age, gender, time from the onset of symptoms, diagnostic procedures, surgical treatment, morbidity and mortality rates were evaluated. 15.78% of patients had a body mass index > 35. 6.76% had chronic obstructive pulmonary disease, 6.76% had cardiac disease, 10.52% had diabetes and 4.51% had sepsis. American Society of Anesthesiology scores were I in 54.13%, II in 35.33%, III in 6.01% and IV in 4.51% of the patients. 27.81% of patients were diagnosed during surgery. The perforation site was the gallbladder fundus in 69.17%, body in 17.30%, Hartman's pouch in 10.53% and cystic duct in 3% of patients. Treatment modalities were laparoscopic cholecystectomy in 82.71%, open cholecystectomy in 3%, percutaneous drainage catheters + laparoscopic cholecystectomy in 3%, laparoscopic cholecystectomy + fistula repair in 10.53% and open cholecystectomy + fistula repair in 0.75% of patients. Mean length of hospital stay was 1.69 days. Mortality and morbidity rates were 8.27% and 10.52%, respectively. Histopathology results were acute cholecystitis in 69.93%, chronic cholecystitis in 20.30% and acute exacerbation over chronic cholecystitis in 9.77% of patients. Appropriate classification and management of perforated cholecystitis is essential. Laparoscopic cholecystectomy is a safe and feasible method to decrease morbidity in gallbladder perforations.

  14. Perforated peptic ulcer - an update.

    Science.gov (United States)

    Chung, Kin Tong; Shelat, Vishalkumar G

    2017-01-27

    Peptic ulcer disease (PUD) affects 4 million people worldwide annually. The incidence of PUD has been estimated at around 1.5% to 3%. Perforated peptic ulcer (PPU) is a serious complication of PUD and patients with PPU often present with acute abdomen that carries high risk for morbidity and mortality. The lifetime prevalence of perforation in patients with PUD is about 5%. PPU carries a mortality ranging from 1.3% to 20%. Thirty-day mortality rate reaching 20% and 90-d mortality rate of up to 30% have been reported. In this review we have summarized the current evidence on PPU to update readers. This literature review includes the most updated information such as common causes, clinical features, diagnostic methods, non-operative and operative management, post-operative complications and different scoring systems of PPU. With the advancement of medical technology, PUD can now be treated with medications instead of elective surgery. The classic triad of sudden onset of abdominal pain, tachycardia and abdominal rigidity is the hallmark of PPU. Erect chest radiograph may miss 15% of cases with air under the diaphragm in patients with bowel perforation. Early diagnosis, prompt resuscitation and urgent surgical intervention are essential to improve outcomes. Exploratory laparotomy and omental patch repair remains the gold standard. Laparoscopic surgery should be considered when expertise is available. Gastrectomy is recommended in patients with large or malignant ulcer.

  15. Perforated peptic ulcer - an update

    Science.gov (United States)

    Chung, Kin Tong; Shelat, Vishalkumar G

    2017-01-01

    Peptic ulcer disease (PUD) affects 4 million people worldwide annually. The incidence of PUD has been estimated at around 1.5% to 3%. Perforated peptic ulcer (PPU) is a serious complication of PUD and patients with PPU often present with acute abdomen that carries high risk for morbidity and mortality. The lifetime prevalence of perforation in patients with PUD is about 5%. PPU carries a mortality ranging from 1.3% to 20%. Thirty-day mortality rate reaching 20% and 90-d mortality rate of up to 30% have been reported. In this review we have summarized the current evidence on PPU to update readers. This literature review includes the most updated information such as common causes, clinical features, diagnostic methods, non-operative and operative management, post-operative complications and different scoring systems of PPU. With the advancement of medical technology, PUD can now be treated with medications instead of elective surgery. The classic triad of sudden onset of abdominal pain, tachycardia and abdominal rigidity is the hallmark of PPU. Erect chest radiograph may miss 15% of cases with air under the diaphragm in patients with bowel perforation. Early diagnosis, prompt resuscitation and urgent surgical intervention are essential to improve outcomes. Exploratory laparotomy and omental patch repair remains the gold standard. Laparoscopic surgery should be considered when expertise is available. Gastrectomy is recommended in patients with large or malignant ulcer. PMID:28138363

  16. Medical image of the week: eosphageal perforation

    Directory of Open Access Journals (Sweden)

    Bilal J

    2015-04-01

    Full Text Available No abstract available. Article truncated after 150 words. A 74 year old man with a past medical history of esophageal strictures status post dilatation, coronary artery disease status post CABG, and atrial fibrillation presented to hospital with complaints of severe chest pain that began after the consumption of tortilla chips one hour prior to presentation. Electrocardiogram and cardiac enzymes were not consistent with acute coronary syndrome. Chest X-ray was consistent with a widened mediastinal silhouette. Contrast esophogram was negative for extra luminal extravasation. CT scan of the chest with oral contrast demonstrated thickening of the mid-thoracic esophagus with an extra-luminal focus of gas in the mediastinum along with fluid along the inferior aspect of the esophagus (Figures 1 and 2. These findings were concerning for esophageal perforation. The patient was taken to the operating room for endoscopy which showed micro perforation in mid-esophagus. Esophageal perforation remains a highly morbid condition. Mortality rates are based predominantly on time of ...

  17. Use of Computed Tomography to Determine Perforation in Patients With Acute Appendicitis.

    Science.gov (United States)

    Gaskill, Cameron E; Simianu, Vlad V; Carnell, Jonathan; Hippe, Daniel S; Bhargava, Puneet; Flum, David R; Davidson, Giana H

    Urgent appendectomy has long been the standard of care for acute appendicitis. Six randomized trials have demonstrated that antibiotics can safely treat appendicitis, but approximately 1 in 4 of these patients eventually requires appendectomy. Overall treatment success may be limited by complex disease including perforation. Patients׳ success on antibiotic therapy may depend on preoperative identification of complex disease on imaging. However, the effectiveness of computed tomography (CT) in differentiating complex disease including perforated from nonperforated appendicitis remains to be determined. The purpose of this study was to assess the preoperative diagnostic accuracy of CT in determining appendiceal perforation in patients operated for acute appendicitis. We performed a retrospective review of pathology and radiology reports from consecutive patients who presented to the emergency department with suspicion for acute appendicitis between January 2012 and May 2015. CT scans were re-reviewed by abdominal imaging fellowship-trained radiologists using standardized criteria, and the radiologists were blinded to pathology and surgical findings. Radiologists specifically noted presence or absence of periappendiceal gas, abscess, appendicolith, fat stranding, and bowel wall thickening. The overall radiologic impression as well as these specific imaging findings was compared to results of pathology and operative reports. Pathology reports were considered the standard for diagnostic accuracy. Eighty-nine patients (65% male, average age of 34 years) presenting with right lower quadrant pain underwent CT imaging and prompt appendectomy. Final pathology reported perforation in 48% (n = 43) of cases. Radiologic diagnosis of perforation was reported in 9% (n = 8), correctly identifying perforation in 37.5% (n = 3), and incorrectly reporting perforation in 62.5% of nonperforated cases per pathology. Radiology missed 93% (n = 40) of perforations postoperatively diagnosed

  18. Perforated Meckel's diverticulum in omphalocele

    Directory of Open Access Journals (Sweden)

    Hanna Jin

    2017-02-01

    Full Text Available Meckel's diverticulum is a rare condition in neonates with reports of concurrent Meckel's diverticulum and omphalocele being few. Herein, we present a case of omphalocele associated with perforated Meckel's diverticulum.

  19. Vitrectomy in double-perforation gunshot injury

    Directory of Open Access Journals (Sweden)

    Abd El Alim Mohamed A

    2013-11-01

    Full Text Available Ahmed Abd El Alim MohamedOphthalmology department, Ain Shams University, Cairo, EgyptObjective: This study sought to evaluate the result of pars plana vitrectomy in patients with gunshot wounds involving double perforation.Methods: This was a retrospective, noncomparative, interventional case series.Results: Eighteen patients (18 eyes with double-perforation gunshot injuries were treated from February 2010 to March 2012. The group included 16 men (88% and two women (11%; the mean age was 24 (15–33 years. In each case, vitrectomy was scheduled 1–6 weeks after repair of the entrance site. Associated retinal detachments were observed in two eyes (11%, retinal incarceration was observed surrounding the exit site in three eyes (16%, and retention of an intraocular foreign body was observed in two cases. After a follow-up period of 8 ± 2 months, two eyes (11% had achieved visual acuity (VA of 0.5, nine eyes (50% had achieved VA between 0.5 and 0.1, and seven eyes (38% had achieved VA between 0.1 and hand movement. The main reasons for functional failure (VA 0.1 to hand movement were macular dragging (due to fibrosis at the exit site near the macula in seven cases (38%, submacular hemorrhage in four cases (22%, and epimacular fibrosis in five cases (27%. All cases developed postoperative exotropia. One case (5% developed postoperative hemorrhage. No cases exhibited signs of postoperative redetachment.Conclusion: The outcome of pars plana vitrectomy in cases with double perforations is variable. Factors including the surgeon's skill level, the time to surgery, and the efficacy of the intraocular tamponade affect the postoperative outcome.Keywords: pars plana vitrectomy, gunshot injury, double perforation

  20. Lack of utility of measuring serum bilirubin concentration in distinguishing perforation status of pediatric appendicitis.

    Science.gov (United States)

    Bonadio, William; Bruno, Santina; Attaway, David; Dharmar, Logesh; Tam, Derek; Homel, Peter

    2017-06-01

    Pediatric appendicitis is a common, potentially serious condition. Determining perforation status is crucial to planning effective management. Determine the efficacy of serum total bilirubin concentration [STBC] in distinguishing perforation status in children with appendicitis. Retrospective review of 257 cases of appendicitis who received abdominal CT scan and measurement of STBC. There were 109 with perforation vs 148 without perforation. Although elevated STBC was significantly more common in those with [36%] vs without perforation [22%], the mean difference in elevated values between groups [0.1mg/dL] was clinically insignificant. Higher degrees of hyperbilirubinemia [>2mg/dL] were rarely encountered [5%]. Predictive values for elevated STBC in distinguishing perforation outcome were imprecise [sensitivity 38.5%, specificity 78.4%, PPV 56.8%, NPV 63.4%]. ROC curve analysis of multiple clinical and other laboratory factors for predicting perforation status was unenhanced by adding the STBC variable. Specific analysis of those with perforated appendicitis and percutaneously-drained intra-abdominal abscess which was culture-positive for Escherichia coli showed an identical rate of STBC elevation compared to all with perforation. The routine measurement of STBC does not accurately distinguish perforation status in children with appendicitis, nor discern infecting organism in those with perforation and intra-abdominal abscess. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. An unusual cause of duodenal perforation due to a lollipop stick

    Directory of Open Access Journals (Sweden)

    Mi Jin Kim

    2013-04-01

    Full Text Available Children have a natural tendency to explore objects with their mouths; this can result in the swallowing of foreign objects. Most ingested foreign bodies pass uneventfully through the gastrointestinal tract.However, some foreign bodies cause obstruction or perforation of the gastrointestinal tract, requiring surgical intervention. Perforation of the gastrointestinal tract may be associated with considerable morbidity and mortality. The most common sites of intestinal foreign body perforation are the ileocecal and rectosigmoid regions. Foreign body perforation of the duodenum is relatively uncommon. We report the first Korean case of duodenal perforation by an ingested 8-cm lollipop stick. Lollipops are popular with the children and fairly accessible to them, as most parents are not aware of their potential harm. Pediatric clinicians should be aware of the risks associated with lollipop stick ingestion. Our report also describes the feasibility and safety of laparoscopic diagnosis and management of pediatric patients with peritonitis induced by the ingestion of foreign bodies.

  2. Endoscopic Management of Gastrointestinal Leaks and Perforation with Polyglycolic Acid Sheets

    Directory of Open Access Journals (Sweden)

    Sojung Han

    2017-05-01

    Full Text Available Gastrointestinal (GI leakage, fistulae, and perforations can be serious and life threatening. There has been a paradigm shift in the management approach of these conditions, from surgical to conservative, including endoscopic management. Here, we report two cases of endoscopic closure of a GI fistula and perforation using polyglycolic acid (PGA sheets with fibrin glue. The first case is of an anastomotic leak detected after subtotal gastrectomy with gastroduodenostomy. After failed application of endoclips, a PGA sheet was applied, and the fistula was successfully closed. The second case was of a 15-mm large perforated gastric ulcer, which was also successfully closed with a PGA sheet. This is the first case report that PGA sheet was used for the treatment of overt perforation. The outcome of these cases suggest that endoscopic closure using PGA sheets can be considered as a useful alternative for the management of GI leakage, fistulae, and perforations.

  3. Changing trend in emergency surgery for perforated duodenal ulcer

    International Nuclear Information System (INIS)

    Gurteyik, E.

    2003-01-01

    Objective: To evaluate changes in the emergency surgery of the duodenal ulcer. Subjects and Methods: Hospital records of 523 surgically treated patients, with duodenal ulcer perforation, during the period of 25 years 91975-1999) in the same surgical department, was retrospectively analysed. Changing aspects of emergency surgery of peptic ulcer disease, in the recent period, were determined in respect to number of operations per year and in the choice of operative methods. Results: The average number of patients and emergency operations per year was 21. No significant change was observed during the study period. Elective operations gradually decreased in the last ten years, and none was performed in the last 4 years. On the other hand, 226 emergency interventions for duodenal ulcer perforation were performed in the last ten years and 84 interventions in the last 4 years. Definitive anti-ulcer surgery was performed in 42% of patients between 1985 and 1994. Simple closure of the perforation plus treatment with proton pump inhibitors and with anti-Helicobacter pylori medication was the method in 80% during the last year. Conclusion: Emergency surgery for perforated duodenal ulcer preserves its steady rate despite disappearance of elective operations after tremendous progress in medical control of peptic ulcer disease. There is an obvious return from definitive anti-ulcer surgery to simple closure of the perforation followed by antisecretory and antibacterial medications in the recent years. (author)

  4. Gastric cancer perforation: experience from a tertiary care hospital.

    Science.gov (United States)

    Kandel, Bishnu Prasad; Singh, Yogendra; Singh, Keshav Prasad; Khakurel, Mahesh

    2013-01-01

    Gastric cancer perforation can occurs in advanced stage of the disease and is often associated with a high morbidity and mortality. Peritonitis due to perforation needs emergency laparotomy and different surgical procedures can be performed for definitive treatment. Surgical procedures largely depend on the stage of the disease and general condition of the patient. This study was carried out to evaluate the outcome and role of different surgical procedures in gastric cancer perforation. Medical record of patients with gastric perforation, who were treated during ten years period, was reviewed retrospectively. Data regarding clinical presentation, surgical procedures, staging and survival of patients were obtained. Features suggestive of diffuse peritonitis were evident in all cases. The majority of the patients underwent emergency surgery except one who died during resuscitation. The majority of patients were in stage III and stage IV. Surgical procedure includes simple closure and omental patch in five patients, simple closure and gastrojejunostomy in nine patients, gastrectomy in six patients and Devine's antral exclusion in one patient. Surgical site infection was the most common (45.5%) postoperative complication. Four patients died within one month of the surgery. Three patients who underwent gastrectomy survived for one year and one patient survived for five years. Although gastric cancer perforation usually occurs in advanced stage of the disease, curative resection should be considered as far as possible.

  5. Rare occupational cause of nasal septum perforation: Nickel exposure

    Directory of Open Access Journals (Sweden)

    Ertugrul Cagri Bolek

    2017-10-01

    Full Text Available Many etiologies are held accountable for nasal septum perforations. Topical nasal drug usage, previous surgeries, trauma, nose picking, squamous cell carcinoma, some rheumatological disorders such as granulomatosis with polyangiitis (Wegener granulomatosis, some infectious diseases such as syphilis and leprosy are among the causes of the perforations. Occupational heavy metal exposures by inhalation rarely may also cause nasal septum perforation. Here, we present a 29-year-old patient without any known diseases, who is a worker at a metallic coating and nickel-plating factory, referred for investigation of his nasal cartilage septum perforation from an otorhinolaryngology clinic. The patient questioning, physical examination and laboratory assessment about rheumatic and infectious diseases were negative. There was a metallic smell in the breath during the physical examination. The analysis showed serum nickel level at 31 μg/l and urine nickel at 18 μg/l (84.11 μg/g creatinine. Other possible serum and urine heavy metal levels were within normal ranges. Nickel exposure is usually together with other heavy metals (chromium or cadmium, it is rarely alone. Nickel ingested by inhalation usually leads to respiratory problems such as reduced olfactory acuity, ulcers, septum perforation or tumors of the nasal sinuses. This case demonstrates the importance of occupational anamnesis and awareness of diagnosis. Int J Occup Med Environ Health 2017;30(6:963–967

  6. Duodenal perforation precipitated by scrub typhus

    Directory of Open Access Journals (Sweden)

    Raghunath Rajat

    2015-01-01

    Full Text Available Scrub typhus is an acute febrile illness usually presenting with fever, myalgia, headache, and a pathognomonic eschar. Severe infection may lead to multiple organ failure and death. Gastrointestinal tract involvement in the form of gastric mucosal erosions and ulcerations owing to vasculitis resulting in gastrointestinal bleeding is common. This process may worsen a pre-existent asymptomatic peptic ulcer, causing duodenal perforation, and present as an acute abdomen requiring surgical exploration. We report the case of a patient with no previous symptoms or risk factors for a duodenal ulcer, who presented with an acute duodenal perforation, probably precipitated by scrub typhus infection.

  7. Bowel Perforation in Premature Infants with Necrotizing Enterocolitis: Risk Factors and Outcomes

    Directory of Open Access Journals (Sweden)

    Lingling Yu

    2016-01-01

    Full Text Available We aim to determine risk factors and clinical outcomes for bowel perforation in premature infants with NEC. We analyzed clinical data of 57 cases of premature infants with NEC at our NICU between January 2010 and December 2012. Based on the presence of bowel perforation, we divided these infants into two groups: perforated NEC group (n=10 and nonperforated NEC group (n=47. We compared general information, clinical characteristics, and laboratory findings between groups. The perforated NEC group, compared to the nonperforated NEC group, had significantly lesser gestational age, lower birth weight, higher prevalence of apnea, mechanical ventilation, sepsis and shock, lower blood pH, higher levels of blood glucose, abnormal WBC count and thrombocytopenia, and elevated CRP (all P<0.05. Moreover, the perforated NEC group had significantly longer durations of fasting and TPN usage, higher incidences of EUGR and cholestasis, longer duration of antibiotics, higher frequency of advanced antibiotics use, and poorer prognosis than the nonperforated NEC group (all P<0.05. Bowel perforation in premature infants with NEC was associated with multiple risk factors. Early identification of some of these risk factors in premature infants with NEC may help implement early intervention to reduce the incidence of bowel perforation and thereby improve the prognosis.

  8. Soft error rate simulation and initial design considerations of neutron intercepting silicon chip (NISC)

    Science.gov (United States)

    Celik, Cihangir

    -scale technologies. Prevention of SEEs has been studied and applied in the semiconductor industry by including radiation protection precautions in the system architecture or by using corrective algorithms in the system operation. Decreasing 10B content (20%of natural boron) in the natural boron of Borophosphosilicate glass (BPSG) layers that are conventionally used in the fabrication of semiconductor devices was one of the major radiation protection approaches for the system architecture. Neutron interaction in the BPSG layer was the origin of the SEEs because of the 10B (n,alpha) 7Li reaction products. Both of the particles produced have the capability of ionization in the silicon substrate region, whose thickness is comparable to the ranges of these particles. Using the soft error phenomenon in exactly the opposite manner of the semiconductor industry can provide a new neutron detection system based on the SERs in the semiconductor memories. By investigating the soft error mechanisms in the available semiconductor memories and enhancing the soft error occurrences in these devices, one can convert all memory using intelligent systems into portable, power efficient, directiondependent neutron detectors. The Neutron Intercepting Silicon Chip (NISC) project aims to achieve this goal by introducing 10B-enriched BPSG layers to the semiconductor memory architectures. This research addresses the development of a simulation tool, the NISC Soft Error Analysis Tool (NISCSAT), for soft error modeling and analysis in the semiconductor memories to provide basic design considerations for the NISC. NISCSAT performs particle transport and calculates the soft error probabilities, or SER, depending on energy depositions of the particles in a given memory node model of the NISC. Soft error measurements were performed with commercially available, off-the-shelf semiconductor memories and microprocessors to observe soft error variations with the neutron flux and memory supply voltage. Measurement

  9. Risk factors for reintervention after surgery for perforated gastroduodenal ulcer

    DEFF Research Database (Denmark)

    Hasselager, R B; Lohse, N; Duch, P

    2016-01-01

    BACKGROUND: Perforated gastroduodenal ulcer carries a high mortality rate. Need for reintervention after surgical repair is associated with worse outcome, but knowledge on risk factors for reintervention is limited. The aim was to identify prognostic risk factors for reintervention after perforated...... gastroduodenal ulcer in a nationwide cohort. METHODS: All patients treated surgically for perforated gastroduodenal ulcer in Denmark between 2003 and 2014 were included using data from the Danish Clinical Register of Emergency Surgery. Potential risk factors for reintervention were assessed, and their crude...... and adjusted associations calculated by the competing risks subdistribution hazards approach. RESULTS: A total of 4086 patients underwent surgery for perforated gastroduodenal ulcer during the study interval. Median age was 71·1 (i.q.r. 59·6-81·0) years and the overall 90-day mortality rate was 30·8 per cent...

  10. Posterior perforation of gastric ulcer: a rare surgical emergency ...

    African Journals Online (AJOL)

    BACKGROUND:Gastric ulcer perforation is a rare surgical emergency.Posterior gastric ulcer is even rarer and usually has a delayed presentation with attendant greater morbidity and mortality. AIM:To report a case of posterior perforation of gastric ulcer and review the literature. CASE REPORT:A 65yr old driver was seen in ...

  11. Semiconducting lithium indium diselenide: Charge-carrier properties and the impacts of high flux thermal neutron irradiation

    Science.gov (United States)

    Hamm, Daniel S.; Rust, Mikah; Herrera, Elan H.; Matei, Liviu; Buliga, Vladimir; Groza, Michael; Burger, Arnold; Stowe, Ashley; Preston, Jeff; Lukosi, Eric D.

    2018-06-01

    This paper reports on the charge carrier properties of several lithium indium diselenide (LISe) semiconductors. It was found that the charge collection efficiency of LISe was improved after high flux thermal neutron irradiation including the presence of a typically unobservable alpha peak from hole-only collection. Charge carrier trap energies of the irradiated sample were measured using photo-induced current transient spectroscopy. Compared to previous studies of this material, no significant differences in trap energies were observed. Through trap-filled limited voltage measurements, neutron irradiation was found to increase the density of trap states within the bulk of the semiconductor, which created a polarization effect under alpha exposure but not neutron exposure. Further, the charge collection efficiency of the irradiated sample was higher (14-15 fC) than that of alpha particles (3-5 fC), indicating that an increase in hole signal contribution resulted from the neutron irradiation. Finally, it was observed that significant charge loss takes place near the point of generation, producing a significant scintillation response and artificially inflating the W-value of all semiconducting LISe crystals.

  12. ASSESSMENT OF SEVERITY OF PERFORATED PERITONITIS USING MODIFIED APACHE II SCORE

    Directory of Open Access Journals (Sweden)

    L. Rajeswar Reddy

    2016-06-01

    Full Text Available Acute generalised peritonitis from gastrointestinal hollow viscus perforation is a potentially life threatening condition. It is a common surgical emergency in many general surgical units in the developing countries and it is often associated with high morbidity and mortality. Grading the severity of acute peritonitis has assisted in no small way in decision making and has improved therapy in the management of severely ill patients. Empirically based risk assessment for important clinical events has been extremely useful in evaluating new therapies, in monitoring resources for effective use and improving quality of care. MATERIAL AND METHODS A prospective survey of patients with acute generalised peritonitis due to gastrointestinal perforation was carried out in general surgical wards of KIMS Hospital, Amalapuram during the period starting from July 2013-November 2016. The study population consisted of 50 consecutive patients who had laparotomy during the study period for acute peritonitis due to gastrointestinal perforation, after diagnostic conformation. RESULT AND DISCUSSION The most common cause of peritonitis in our study was perforated duodenal ulcer (31 cases, followed by appendicular perforation (7 cases, followed by stomach perforation (7 cases. Despite delay in seeking treatment, the overall mortality rate (14% was favourably comparable with other published series.

  13. New Icosahedral Boron Carbide Semiconductors

    Science.gov (United States)

    Echeverria Mora, Elena Maria

    Novel semiconductor boron carbide films and boron carbide films doped with aromatic compounds have been investigated and characterized. Most of these semiconductors were formed by plasma enhanced chemical vapor deposition. The aromatic compound additives used, in this thesis, were pyridine (Py), aniline, and diaminobenzene (DAB). As one of the key parameters for semiconducting device functionality is the metal contact and, therefore, the chemical interactions or band bending that may occur at the metal/semiconductor interface, X-ray photoemission spectroscopy has been used to investigate the interaction of gold (Au) with these novel boron carbide-based semiconductors. Both n- and p-type films have been tested and pure boron carbide devices are compared to those containing aromatic compounds. The results show that boron carbide seems to behave differently from other semiconductors, opening a way for new analysis and approaches in device's functionality. By studying the electrical and optical properties of these films, it has been found that samples containing the aromatic compound exhibit an improvement in the electron-hole separation and charge extraction, as well as a decrease in the band gap. The hole carrier lifetimes for each sample were extracted from the capacitance-voltage, C(V), and current-voltage, I(V), curves. Additionally, devices, with boron carbide with the addition of pyridine, exhibited better collection of neutron capture generated pulses at ZERO applied bias, compared to the pure boron carbide samples. This is consistent with the longer carrier lifetimes estimated for these films. The I-V curves, as a function of external magnetic field, of the pure boron carbide films and films containing DAB demonstrate that significant room temperature negative magneto-resistance (> 100% for pure samples, and > 50% for samples containing DAB) is possible in the resulting dielectric thin films. Inclusion of DAB is not essential for significant negative magneto

  14. Testing FLUKA on neutron activation of Si and Ge at nuclear research reactor using gamma spectroscopy

    Science.gov (United States)

    Bazo, J.; Rojas, J. M.; Best, S.; Bruna, R.; Endress, E.; Mendoza, P.; Poma, V.; Gago, A. M.

    2018-03-01

    Samples of two characteristic semiconductor sensor materials, silicon and germanium, have been irradiated with neutrons produced at the RP-10 Nuclear Research Reactor at 4.5 MW. Their radionuclides photon spectra have been measured with high resolution gamma spectroscopy, quantifying four radioisotopes (28Al, 29Al for Si and 75Ge and 77Ge for Ge). We have compared the radionuclides production and their emission spectrum data with Monte Carlo simulation results from FLUKA. Thus we have tested FLUKA's low energy neutron library (ENDF/B-VIIR) and decay photon scoring with respect to the activation of these semiconductors. We conclude that FLUKA is capable of predicting relative photon peak amplitudes, with gamma intensities greater than 1%, of produced radionuclides with an average uncertainty of 13%. This work allows us to estimate the corresponding systematic error on neutron activation simulation studies of these sensor materials.

  15. Dual detector neutron lifetime log: theory and practical applications

    International Nuclear Information System (INIS)

    Serpas, C.J.; Wichmann, P.A.; Fertl, W.H.; DeVries, M.R.; Rndall, R.R.

    1977-01-01

    The Neutron Lifetime Log instrumentation has continued to evolve and now is equipped with dual detectors for increased ease in gas detection and also a ratio response for a simultaneous porosity determination. A good deal of experimentation was involved to minimize both lithology and salinity effects on the porosity indication. This paper contains a discussion of the theory and concepts related to the application of the Dual Detector Neutron Lifetime Log (DNLL). It is important to note that with these advances the recording of thermal neutron capture cross section (Σ) remains consistent with the past measurements of earlier generations of instruments as the most accurate determination of this parameter. A number of field examples of the newly logged results are shown. These field cases include Dual Detector NLL's run thru the drill strings of highly deviated holes when difficulties were encountered in getting conventional open hole logs to bottom, logs thru open perforations and hot radioactive zones, comparisons of the large and small diameter instruments, logs with anomalous fluids in the annulus, logs thru multiple casing strings, and a number of other examples

  16. Single event upset in static random access memories in atmospheric neutron environments

    CERN Document Server

    Arita, Y; Ogawa, I; Kishimoto, T

    2003-01-01

    Single-event upsets (SEUs) in a 0.4 mu m 4Mbit complementary metal oxide semiconductor (CMOS) static random access memory (SRAM) were investigated in various atmospheric neutron environments at sea level, at an altitude of 2612 m mountain, at an altitude of commercial airplane, and at an underground depth of 476m. Neutron-induced SEUs increase with the increase in altitude. For a device with a borophosphosilicate glass (BPSG) film, SEU rates induced by thermal neutrons increase with the decrease in the cell charge of a memory cell. A thermal neutron-induced SEU is significant in SRAMs with a small cell charge. With the conditions of small cell charge, thermal neutron-induced SEUs account for 60% or more of the total neutron-induced SEUs. The SEU rate induced by atmospheric thermal neutrons can be estimated by an acceleration test using sup 2 sup 5 sup 2 Cf. (author)

  17. Spontaneous Uterine Perforation of Pyometra Presenting as Acute Abdomen

    Directory of Open Access Journals (Sweden)

    Toshihiro Kitai

    2014-01-01

    Full Text Available Pyometra is the accumulation of pus in the uterine cavity, and spontaneous perforation of pyometra resulting in generalized diffuse peritonitis is extremely uncommon. We report a rare case of diffuse peritonitis caused by spontaneous perforation of pyometra. A 66-year-old postmenopausal woman with diffuse abdominal pain and vomiting was admitted to our institution. She had a history of mixed connective-tissue disease and had been taking steroids for 20 years. Under a diagnosis of generalized peritonitis secondary to perforation of the gastrointestinal tract or uterus, supravaginal hysterectomy and bilateral salpingo-oophorectomy were performed. Unfortunately, wound dehiscence and infection occurred during the postoperative course, which were exacerbated by her immunocompromised state. Despite intensive care and a course of antibiotics, the patient died of multiple organ failure resulting from sepsis on the 36th postoperative day. Although correct diagnosis, early intervention, and proper treatment can reduce morbidity and mortality of spontaneous perforation of pyometra, if severe infection occurs, this disease can be life threatening for immunocompromised hosts.

  18. An investigation of the damaged zone created by perforating

    International Nuclear Information System (INIS)

    Pucknell, J.K.; Behrmann, L.A.

    1991-01-01

    This paper reports on underbalance perforation flow experiments performed on reservoir and outcrop sandstones to investigate the perforation damaged zone. Cores from several different formations were perforated under reservoir conditions. After perforating, the cores were examined using CAT scans (Computer Aided tomography), thin sections and mercury porosimetry. In conjunction with these measurements, permeabilities in the damaged zone were measured using a minipermeameter and radial flow permeameter or were estimated from pore size distribution. The density and porosity of the damaged zone (at least for saturated rocks) is essentially the same as that in the undamaged rock. The damaged zone is not compacted, contrary to suggestions made in earlier work. However, the creation of this zone involves the destruction of large pores. The volume lost from these pores is replaced by microfractures created when rock grains are fractured by penetration of the shaped charge jet. This reduction in the average pore size causes a reduction in the permeability with the damaged zone. Although direct measurement of this permeability was made difficult by naturally occurring permeability variations, unambiguous measurements were obtained

  19. Costs of treating bleeding and perforated peptic ulcers in The Netherlands.

    Science.gov (United States)

    de Leest, Helena; van Dieten, Hiske; van Tulder, Maurits; Lems, Willem F; Dijkmans, Ben A C; Boers, Maarten

    2004-04-01

    Gastrointestinal toxicity of nonsteroidal antiinflammatory drugs includes perforations and bleeds. Several preventive strategies are being tested for cost-effectiveness, but little is known about the costs of the complications they are trying to prevent. We estimated the direct costs of hospital treatment of bleeding and perforated ulcers in a university hospital, from data in discharge letters and the hospital management information system. Eligible patients had been treated in the VU University Medical Center between January 1997 and August 2000 for an ulcer bleed or perforation (International Classification of Diseases code 531-4). Resource use comprised hospitalization days and diagnostic and therapeutic interventions. Insurance claim prices determined the costs from the payers' perspective. In a secondary analysis we excluded resource use that was clearly related to the treatment of comorbid illness. Fifty-three patients with a bleeding (n = 35) or perforated ulcer (n = 15) or both (n = 3) were studied, including 14 with comorbidity; 22 complications occurred in the stomach, 29 in the duodenum, one in both stomach and duodenum, and one after partial gastrectomy. A simultaneous bleed and perforation was most expensive (26,000 euro), followed by perforation (19,000 euro) and bleeding (12,000 euro). A bleed in the duodenum was more expensive than in the stomach (13,000 euro vs 10,000 euro), while the opposite was seen for perforations (13,000 euro vs 21,000 euro). Comorbidity increased costs substantially: even after correction for procedures unrelated to the ulcer complication, comorbidity more than doubled the costs of treatment. Treatment of complicated ulcers is expensive, especially in patients with comorbid conditions.

  20. Perforated Gastric Ulcer Associated with Anti-Angiogenic Therapy

    Directory of Open Access Journals (Sweden)

    Diogo Libânio

    2017-08-01

    Full Text Available Anti-angiogenic therapy with bevacizumab, an inhibitor of vascular endothelial growth factor, is commonly used in metastatic colorectal cancer and is rarely associated with gastrointestinal perforation, perforation being more frequent in the primary tumor site or at the anastomotic level. We present the case of a 64-year-old male with stage IV rectal adenocarcinoma who was on palliative chemotherapy with FOLFOX and bevacizumab. After the 4th chemotherapy cycle, our patient started fever and epigastric pain. He was hemodynamically stable, and signs of peritoneal irritation were absent. There were no alterations in the abdominal X-ray, and C-reactive protein was markedly elevated. A CT scan revealed a de novo thickness in the gastric antrum. Upper digestive endoscopy showed an ulcerated 40-mm lesion in the angulus, with a 20-mm orifice communicating with an exsudative cavity revested by the omentum. A conservative approach was decided including fasting, broad-spectrum intravenous antibiotics, and proton-pump inhibitors. Subsequent gastroduodenal series showed no contrast extravasation, allowing the resumption of oral nutrition. Esophagogastroduodenoscopy after 8 weeks showed perforation closure. Biopsies did not show neoplastic cells or Heliobacter pylori infection. Although the success in the conservative management of perforation allowing the maintenance of palliative chemotherapy (without bevacizumab, the patient died after 4 months due to liver failure. The reported case shows an uncommon endoscopic finding due to a rare complication of anti-angiogenic therapy. Additionally, it reminds clinicians that a history of gastroduodenal ulcers should be actively sought before starting anti-angiogenic treatment and that suspicion for perforation should be high in these cases.

  1. Conservative Management of Colonoscopic Perforation: A Case Report.

    Science.gov (United States)

    Parsa, Hossein; Miroliaee, Arash; Doagoo, Zafar; Sina, Saeed

    2017-07-01

    Colonoscopy is widely used for the diagnosis, treatment and a follow up of colorectal diseases. Perforation of the large bowel during elective colonoscopy is rare but serious life threatening complication. We report a 51-year-old woman who experienced recto sigmoid perforation during diagnostic colonoscopy. During 8 days of total hospitalization, she spent 3 days in ICU with gastrointestinal rest. The patient was hydrated and took intravenous antibiotics. In take-output and temperature were closely monitored. Serial abdominal examinations were performed to rule out peritonitis. After transferring to surgery ward in the day 4, liquid diet started slowly, and she was ambulated. At the day 8, she was discharged with the good clinical condition. Conservative management of the patients with early diagnosis of perforation and no signs and symptoms of peritonitis or sepsis could be the modality of choice.

  2. Primary tubercular caecal perforation: a rare clinical entity

    Directory of Open Access Journals (Sweden)

    Moses Sonia

    2010-03-01

    Full Text Available Abstract Background Intestinal tuberculosis is a common problem in endemic areas, causing considerable morbidity and mortality. An isolated primary caecal perforation of tubercular origin is exceptionally uncommon. Case presentation We report the case of a 39 year old male who presented with features of perforation peritonitis, which on laparotomy revealed a caecal perforation with a dusky appendix. A standard right hemicolectomy with ileostomy and peritoneal toileting was done. Histopathology revealed multiple transmural caseating granulomas with Langerhans-type giant cells and acid-fast bacilli, consistent with tuberculosis, present only in the caecum. Conclusions We report this extremely rare presentation of primary caecal tuberculosis to sensitize the medical fraternity to its rare occurrence, which will be of paramount importance owing to the increasing incidence of tuberculosis all over the world, especially among the developing countries.

  3. A semiconductor parameter analyzer for ionizing radiation detectors

    International Nuclear Information System (INIS)

    Santos, Luiz A.P.

    2009-01-01

    Electrometers and ion chamber are normally used to make several types of measurements in a radiation field and there is a unique voltage applied to each detector type. Some electronic devices that are built of semiconductor materials like silicon crystal can also be used for the same purpose. In this case, a characteristic curve of the device must be acquired to choose an operation point which consists of an electrical current or voltage to be applied to the device. Unlike ion chambers, such an electronic device can have different operation points depending on its current versus voltage curve (I x V). The best operation point of the device is also a function of the radiation, energy, dose rate and fluence. The purpose of this work is to show a semiconductor parameter analyzer built to acquire I x V curves as usually, and the innovation here is the fact that it can be used to obtain such a parametric curve when a quad-polar device is under irradiation. The results demonstrate that the system is a very important tool to scientists interested to evaluate a semiconductor detector before, during and after irradiation. A collection of results for devices under an X-ray beam and a neutron fluence are presented: photodiode, phototransistors, bipolar transistor and MOSFET. (author)

  4. Perforated peptic ulcer in Tikur Anbessa Hospital: a review of 74 cases.

    Science.gov (United States)

    Ersumo, Tessema; W/Meskel, Yidnekachew; Kotisso, Berhanu

    2005-01-01

    Little is known on the pattern of perforated peptic ulcer in Ethiopia. To evaluate the early, outcome of management, a five-year retrospective analysis of 74 operated cases of perforated peptic ulcer was undertaken. Perforated peptic ulcer accounted for 3.4% of the adult emergency surgical procedures. The mean age was 32.6 years, with a male to female ratio of 7.2 to 1.0. Fifty-six percent of the cases were unmarried. In nearly 22.0% of the patients, no previous history of peptic ulcer disease was documented. Delay in diagnosis was noted in 95% of the cases. Most patients had duodenal ulcer perforation, and about 78% had purulent peritonitis at laparotomy. Fourteen died in hospital. Early presentation of patients to surgical care facilities may reduce morbidity and mortality in cases of peptic ulcer perforation.

  5. Giant trochanteric pressure sore: Use of a pedicled chimeric perforator flap for cover

    Directory of Open Access Journals (Sweden)

    Mehrotra Sandeep

    2009-01-01

    Full Text Available Pressure sores are increasing in frequency commensurate with an ageing population with multi-system disorders and trauma. Numerous classic options are described for providing stable wound cover. With the burgeoning knowledge on perforator anatomy, recent approaches focus on the use of perforator-based flaps in bedsore surgery. A giant neglected trochanteric pressure sore in a paraplegic is presented. Since conventional options of reconstruction appeared remote, the massive ulcer was successfully managed by a chimeric perforator-based flap. The combined muscle and fasciocutaneous flaps were raised as separate paddles based on the anterolateral thigh perforator branches and provided stable cover without complications. Perforators allow versatility in managing complex wounds without compromising on established principles.

  6. Detection system for neutron β decay correlations in the UCNB and Nab experiments

    Energy Technology Data Exchange (ETDEWEB)

    Broussard, L.J., E-mail: broussardlj@ornl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Zeck, B.A. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); North Carolina State University, Raleigh, NC 27695 (United States); Adamek, E.R. [Indiana University, Bloomington, IN 47405 (United States); Baeßler, S. [University of Virginia, Charlottesville, VA 22904 (United States); Birge, N. [University of Tennessee, Knoxville, TN 37996 (United States); Blatnik, M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Cleveland State University, Cleveland, OH 44115 (United States); Bowman, J.D. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Brandt, A.E. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); North Carolina State University, Raleigh, NC 27695 (United States); Brown, M. [University of Kentucky, Lexington, KY 40506 (United States); Burkhart, J. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Callahan, N.B. [Indiana University, Bloomington, IN 47405 (United States); Clayton, S.M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Crawford, C. [University of Kentucky, Lexington, KY 40506 (United States); Cude-Woods, C. [North Carolina State University, Raleigh, NC 27695 (United States); Currie, S. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Dees, E.B. [North Carolina State University, Raleigh, NC 27695 (United States); Ding, X. [Virginia Polytechnic Institute & State University, Blacksburg, VA 24061 (United States); Fomin, N. [University of Tennessee, Knoxville, TN 37996 (United States); Frlez, E.; Fry, J. [University of Virginia, Charlottesville, VA 22904 (United States); and others

    2017-03-21

    We describe a detection system designed for precise measurements of angular correlations in neutron β decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for β electron detection with energy thresholds below 10 keV, energy resolution of ∼3 keV FWHM, and rise time of ∼50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of β particles and recoil protons from neutron β decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments to determine the neutron β decay parameters B, a, and b.

  7. Rare occupational cause of nasal septum perforation: Nickel exposure.

    Science.gov (United States)

    Bolek, Ertugrul Cagri; Erden, Abdulsamet; Kulekci, Cagri; Kalyoncu, Umut; Karadag, Omer

    2017-10-06

    Many etiologies are held accountable for nasal septum perforations. Topical nasal drug usage, previous surgeries, trauma, nose picking, squamous cell carcinoma, some rheumatological disorders such as granulomatosis with polyangiitis (Wegener granulomatosis), some infectious diseases such as syphilis and leprosy are among the causes of the perforations. Occupational heavy metal exposures by inhalation rarely may also cause nasal septum perforation. Here, we present a 29-year-old patient without any known diseases, who is a worker at a metallic coating and nickel-plating factory, referred for investigation of his nasal cartilage septum perforation from an otorhinolaryngology clinic. The patient questioning, physical examination and laboratory assessment about rheumatic and infectious diseases were negative. There was a metallic smell in the breath during the physical examination. The analysis showed serum nickel level at 31 μg/l and urine nickel at 18 μg/l (84.11 μg/g creatinine). Other possible serum and urine heavy metal levels were within normal ranges. Nickel exposure is usually together with other heavy metals (chromium or cadmium), it is rarely alone. Nickel ingested by inhalation usually leads to respiratory problems such as reduced olfactory acuity, ulcers, septum perforation or tumors of the nasal sinuses. This case demonstrates the importance of occupational anamnesis and awareness of diagnosis. Int J Occup Med Environ Health 2017;30(6):963-967. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  8. Diagnosing perforated appendicitis in pediatric patients: a new model.

    Science.gov (United States)

    van den Bogaard, Veerle A B; Euser, Sjoerd M; van der Ploeg, Tjeerd; de Korte, Niels; Sanders, Dave G M; de Winter, Derek; Vergroesen, Diederik; van Groningen, Krijn; de Winter, Peter

    2016-03-01

    Studies have investigated sensitivity and specificity of symptoms and tests for diagnosing appendicitis in children. Less is known with regard to the predictive value of these symptoms and tests with respect to the severity of appendicitis. The aim of this study was to determine the predictive value of patient's characteristics and tests for discriminating between perforated and nonperforated appendicitis in children. Pediatric patients who underwent an appendectomy at Spaarne Hospital Hoofddorp, the Netherlands, between January 1, 2009 and December 31, 2013, were included. Baseline patient's characteristics, history, physical examination, laboratory data and results of ultrasounds were collected. Univariate and multivariate logistic regressions were used to determine predictors of perforation. In total, 375 patients were included in this study of which 97 children (25.9%) had significant signs of perforation. Univariate analysis showed that age, duration of complaints, temperature, vomiting, CRP, WBC, different findings on ultrasound and the diameter of the appendix were good predictors of a perforated appendicitis. The final multivariate prediction model included temperature, CRP, clearly visible appendix and free fluids on ultrasound and diameter of the appendix and resulted in an area under the curve (AUC) of 0.91 showing sensitivity and specificity of respectively 85.2% and 81.2%. This prediction model can be used for identification of 'high-risk' children for a perforated appendicitis and might be helpful to prevent complications and longer hospitalization by bringing these children to theater earlier. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Using perforators as recipient vessels (supermicrosurgery) for free flap reconstruction of the knee region.

    Science.gov (United States)

    Hong, Joon Pio; Koshima, Isao

    2010-03-01

    The purpose of this article is to evaluate the feasibility of a perforator as a recipient vessel to reconstruct soft tissue defects of the knee region.From December of 2006 to August of 2008, total of 25 patients underwent reconstructive procedure using either an anterolateral thigh or an upper medial thigh perforator flap. The flaps were anastomosed in a perforator to perforator manner using supermicrosurgery technique.Minimum of 3 perforators were traced around the knee defect. All flaps survived attached to a recipient perforator with artery diameter ranging from 0.4 to 0.9 mm and accompanying veins ranging from 0.4 to 1.2 mm. This approach allowed reduction in time for pedicle and recipient vessel dissection and minimized the trauma involved during isolation of the vessels.Using the perforator as recipient vessel allows an increase in selection for choice of recipient. By using a perforator as recipient, less time is consumed to secure the vessel, does not need long pedicles for flap, is not bound by the condition of major arteries, and minimizes any risk for major vessel injury while having acceptable flap survival.

  10. Typhoid ileal perforation: a 13-year experience

    Directory of Open Access Journals (Sweden)

    Poras Chaudhary

    2015-07-01

    Full Text Available Typhoid fever is endemic in many developing countries with a high rate of complications. Aim of this study is to analyse epidemiological features, clinical presentations, complications and therapeutic outcomes of enteric perforation peritonitis diagnosed and treated in our hospital. Records of total number of 646 patients, who presented with perforation peritonitis due to enteric fever in the surgical emergency unit of Dr Ram Manohar Lohia hospital, New Delhi between January 2001 and December 2013, were reviewed retrospectively. Descriptive statistics was used to analyze the data. Out of 646 patients, 62 (9.59% presented in shock. Stomal, peristomal, local and systemic complications were high in these patients. Primary closure was done in 212 (33.12 patients, primary ileostomy was created in 410 (64.06 patients, and resection and anastomosis was done in 24 (3.75 patients. Thirteen patients (2.01% died of typhoid intestinal perforation. To prevent complications of typhoid fever, in addition to control sanitation, it is also important to control quackery and malpractices. Awareness and education about the disease, its nature and complications will also be of great help.

  11. Influence of delays on perforation risk in adults with acute appendicitis.

    LENUS (Irish Health Repository)

    Kearney, D

    2012-02-03

    PURPOSE: This study analyzed whether prehospital or in-hospital delay was the more significant influence on perforation rates for acute appendicitis and whether any clinical feature designated patients requiring higher surgical priority. METHODS: A retrospective analysis was conducted over one year at a tertiary referral hospital without a dedicated emergency surgical theater. Admission notes, theater logbook, and the Hospital Inpatient Enquiry system were reviewed to identify the characteristics and clinical course of patients aged greater than 16 years who were operated upon for histologically confirmed acute appendicitis. RESULTS: One hundred and fifteen patients were studied. The overall perforation rate was 17 percent. The mean duration of symptoms prior to hospital presentation was 38.1 hours with the mean in-hospital waiting time prior to operation being 23.4 hours. Although body temperature on presentation was significantly greater in patients found to have perforated appendicitis (P < 0.05), only patient heart rate at presentation and overall duration of symptoms, but not in-hospital waiting time, independently predicted perforation by stepwise linear regression modeling. CONCLUSION: In-hospital delay was not an independent predictor of perforation in adults with acute appendicitis although delays may contribute if patients are left to wait unduly. Tachycardia at presentation may be a quantifiable feature of those more likely to have perforation and who should be given higher surgical priority.

  12. [Reconstruction of ankle and foot with combination of free perforator flaps and skin graft].

    Science.gov (United States)

    Yin, Lu; Gong, Ketong; Yin, Zhonggang; Zhang, Bo; Xu, Jianhua

    2017-03-01

    To evaluate the clinical outcomes of free perforator flaps combined with skin graft for reconstruction of ankle and foot soft tissue defects. Between June 2014 and October 2015, 20 cases of ankle and foot soft tissue defects were treated. There were 16 males and 4 females, aged from 19 to 61 years (mean, 43.3 years). Injury was caused by traffic accident in 7 cases, by crashing in 9 cases, and machine twist in 4 cases. The locations were the ankle in 6 cases, the heel in 3 cases, the dorsum pedis in 4 cases, and the plantar forefoot in 7 cases of avulsion injury after toes amputation. The size of wound ranged from 15 cm×10 cm to 27 cm×18 cm. The time from injury to treatment was from 11 to 52 days (mean, 27 days). The anterolateral thigh perforator flap was used in 11 cases, thoracodorsal antery perforator flap in 3 cases, medial sural artery perforator flap in 4 cases, deep inferior epigastric perforator flap in 1 case, and anteromedial thigh perforator flap in 1 case, including 5 chimeric perforator flaps, 5 polyfoliate perforator flaps, 3 flow-through perforator flaps, and 3 conjoined perforator flaps. The size of the perforator flap ranged from 10.0 cm×6.5 cm to 36.0 cm×8.0 cm, the size of skin graft from 5 cm×3 cm to 18 cm×12 cm. Venous crisis occurred in 2 flaps which survived after symptomatic treatment; 18 flaps survived successfully and skin grafting healed well. The follow-up time ranged 4-18 months (mean, 8.3 months). The flaps had good appearance, texture and color, without infection. The patients could walk normally and do daily activities. Only linear scars were observed at the donor sites. Free perforator flap can be used to reconstruct defects in the ankle and foot, especially in the weight-bearing area of the plantar forefoot. A combination of free perforator flap and skin graft is ideal in reconstruction of great soft tissue defects in the ankle and foot.

  13. Perforation in a patient with stercoral colitis and diverticulosis: who did it?

    Directory of Open Access Journals (Sweden)

    Vijaya R. Bhatt

    2014-02-01

    Full Text Available Stercoral colitis with perforation of the colon is an uncommon, yet life-threatening cause of the acute abdomen. No one defining symptom exists for stercoral colitis; it may present asymptomatically or with vague symptoms. Diagnostic delay may result in perforation of the colon resulting in complications, even death. Moreover, stercoral perforation of the colon can also present with localized left lower quadrant abdominal pain masquerading as diverticulitis. Diverticular diseases and stercoral colitis share similar pathophysiology; furthermore, they may coexist, further complicating the diagnostic dilemma. The ability to decide the cause of perforation in a patient with both stercoral colitis and diverticulosis has not been discussed. We, therefore, report this case of stercoral perforation in a patient with diverticulosis and include a discussion of the epidemiology, clinical presentation, and a review of helpful diagnostic clues for a rapid differentiation to allow for accurate diagnosis and treatment.

  14. [An Analysis of Perforated Gastric Cancer with Acute Peritonitis in Our Hospital].

    Science.gov (United States)

    Adachi, Shinichi; Endo, Shunji; Chinen, Yoshinao; Itakura, Hiroaki; Takayama, Hirotoshi; Tsuda, Yujiro; Ueda, Masami; Nakashima, Shinsuke; Ohta, Katsuya; Ikenaga, Masakazu; Yamada, Terumasa

    2018-01-01

    Perforated gastric cancer is relatively rare and the incidence is reported about 1% of all the cases of gastric cancer. We retrospectively analyzed the clinical data of the consecutive 12 patients with perforated gastric cancer who underwent operation in our hospital between January 2005 and December 2016. There were 5 men and 7 women, with an average age of 65.8 years old(34-87). Perforated gastric cancer occurred in the region U(1 cases), M(6 cases), L(5 cases). There were 11 cases with distant metastasis. We could successfully diagnosed as perforated gastric cancer in 8 cases before emergency operation. Gastrectomy was performed in 5 cases. However, the curative resection was performed only 1 case. Prognosis of perforated gastric cancer is poor. We considered as an appropriate two-step surgical strategy that the first step of surgery is an acute peritonitis treatment followed by radical gastrectomy with lymphadenectomy.

  15. Preoperative CT angiography reduces surgery time in perforator flap reconstruction

    NARCIS (Netherlands)

    Smit, Jeroen M.; Dimopoulou, Angeliki; Liss, Anders G.; Zeebregts, Clark J.; Kildal, Morten; Whitaker, Iain S.; Magnusson, Anders; Acosta, Rafael

    The use of perforator flaps in breast reconstructions has increased considerably in the past decade. A disadvantage of the perforator flap is difficult dissection, which results in a longer procedure. During spring 2006, we introduced CT angiography (CTA) as part of the diagnostic work-up in

  16. Perforation af rectum med faekal peritonitis efter staplet haemorideoperation

    DEFF Research Database (Denmark)

    Beuke, Anna-Christina; Pedersen, Mark Ellebaek; Qvist, Niels

    2008-01-01

    Rectal perforation and faecal peritonitis after stapled operation for grade IV haemorrhoids is described. The complication is rare, but surgeons performing the procedure must be familiar with potential risk factors.......Rectal perforation and faecal peritonitis after stapled operation for grade IV haemorrhoids is described. The complication is rare, but surgeons performing the procedure must be familiar with potential risk factors....

  17. Semiconductor apparatus and method of fabrication for a semiconductor apparatus

    NARCIS (Netherlands)

    2010-01-01

    The invention relates to a semiconductor apparatus (1) and a method of fabrication for a semiconductor apparatus (1), wherein the semiconductor apparatus (1) comprises a semiconductor layer (2) and a passivation layer (3), arranged on a surface of the semiconductor layer (2), for passivating the

  18. Critical impact energy for the perforation of metallic plates

    International Nuclear Information System (INIS)

    Aly, S.Y.; Li, Q.M.

    2008-01-01

    This paper investigates the empirical formulae used in engineering practice to predict the critical perforation energy of metallic plates struck by rigid projectiles in the sub-ordnance regime. Main factors affecting the critical perforation energy are identified and valid conditions for each empirical formula are compared. Dimensional analysis is conducted to show the dependence of the non-dimensional critical impact energy on other influential non-dimensional numbers. Available empirical formulae are re-expressed in non-dimensional forms. A modified Jowett/AEA equation is proposed to predict the critical perforation energy of a flat-ended short projectile. The present work increases the confidence of using these empirical formulae and can be regarded as a quick guide for ballistic protection design of metallic shields and steel armour plates

  19. Solid-State Neutron Multiplicity Counting System Using Commercial Off-the-Shelf Semiconductor Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Rozhdestvenskyy, S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-08-09

    This work iterates on the first demonstration of a solid-state neutron multiplicity counting system developed at Lawrence Livermore National Laboratory by using commercial off-the-shelf detectors. The system was demonstrated to determine the mass of a californium-252 neutron source within 20% error requiring only one-hour measurement time with 20 cm2 of active detector area.

  20. A Case Report of Stercoraceous Perforation of the Cecum due to Scybalum

    Directory of Open Access Journals (Sweden)

    HR Khorshidi

    2006-10-01

    Introduction & Objective: Non-traumatic colon perforations are usually caused by malignancy, diverticulum and colitis. Stercoraceous perforation of the colon has rarely been reported in the literature. This lesion is assumed to be produced by the pressure from a hard scybalum resulting in a perforated ulcer with necrotic edges. We report a case of stercoraceous perforation of the cecum due to scybalum. Case: We report a 50-year-old man who had a severe abdominal pain from 3 days ago and had peritonitis in physical exam. He was admitted in Mars, 2005 at Mobasher Kashani Hospital in Hamadan and he was parapelegic from 8 months ago due to trauma in his medical history and then he had severe and chronic constipation that necessitated the use of cathartic drugs. We operated him with diagnosis of peritonitis, and perforation of cecum due to scybalum was seen and right hemicolectomy and colostomy and ileostomy was done. Conclusion: The most common site of colon perforation due to scybalum is rectosigmoid area and cecal perforation is a rare area in the literature. It is presented with peritonitis in old patients that have chronic constipation. It is difficult to diagnose this lesion preoperatively. This lesion was only 11% correctly diagnosed before operation and should be always suspected when a patient with chronic constipation suffers from sudden abdominal pain. Resection and colostomy is the treatment of choice in most situations.

  1. Surgical management of perforated peptic ulcer disease.

    Science.gov (United States)

    Sweeney, K J; Faolain, M O; Gannon, D; Gorey, T F; Kerin, M J

    2006-01-01

    Surgery for perforated peptic ulcer disease is one of the most common emergency procedures carried out in the western world. The role of postoperative empiric Helicobacter Pylori eradication therapy is controversial. The clinical, operative and postoperative surveillance details of 84 consecutive patients who underwent surgery for perforated peptic ulcer were reviewed. All patients underwent omentopexy +/- simple closure followed by proton pump therapy. Patients were followed-up for an average of 44 +/- 19 months. Females were older than male patients (59 +/- 20 vs. 46 + 17 years; pperforated peptic ulcer is associated with a significant perioperative mortality rate. Elderly female patients are particularly at risk.

  2. Non-operative management of perforated peptic ulcer

    International Nuclear Information System (INIS)

    Rahman, M.M.; Ahsan, H.N.; Hossain, M.D.

    2003-01-01

    Objective: The aim of this study was to see the morbidity and mortality in peptic ulcer perforation cases by non-operative management in selected cases. Results: In the selected 54 patients, male: female were 49:05. Nine had history of NSAID intake. There was no mortality. Morbidity analysis showed that three had hepatic abscess, four had pelvic abscess, six took prolonged time for improvement, in two cases conservative treatment had to be abandoned and laparotomy was done in the same hospital admission. Conclusion: Non-operative procedure is a safe and effective measure for the management of perforated peptic ulcer in selected cases. (author)

  3. Acute spontaneous gastric perforation in neonates: A report of three ...

    African Journals Online (AJOL)

    Gastric perforation in neonates is a rare, serious and life-threatening problem. The precise aetiology is obscure in most cases. By virtue of its high mortality rate, it requires prompt recognition and surgical intervention. We report three cases of neonatal gastric perforation managed by early resuscitation and primary repair.

  4. Perforated gastric and duodenal ulcers in an urban African population

    African Journals Online (AJOL)

    Background: Perforations of the stomach and duodenum are frequent causes of acute generalized peritonitis in our environment. This is a prospective study of 331 cases of gastric and duodenal perforations. Study design: A consecutive series of adult patients admitted and treated for acute generalized peritonitis due to ...

  5. The "stamp method" : a new treatment for perforated peptic ulcer?

    NARCIS (Netherlands)

    Bertleff, M.J.O.E.; Liem, RSB; Robinson, PH; Bonjer, HJ; Lange, J. F.; Bartels, H.; van der Werf, J.F.A.

    Background: The aim of this study was to develop a simple method for closure of a perforated peptic ulcer, making it more accessible for laparoscopic surgery. Methods: An experimental pilot study was performed using five male Wistar rats. The perforation was closed by a bioabsorbable patch made of

  6. Percutaneous drainage in conservative therapy for perforated gastroduodenal ulcers.

    Science.gov (United States)

    Oida, Takatsugu; Kano, Hisao; Mimatsu, Kenji; Kawasaki, Atsushi; Kuboi, Youichi; Fukino, Nobutada; Kida, Kazutoshi; Amano, Sadao

    2012-01-01

    The management of peptic ulcers has dramatically changed and the incidence of elective surgery for gastroduodenal peptic ulcers has markedly decreased; hence, the incidence of emergency surgery for perforated peptic ulcers has slightly increased. In select cases, conservative therapy can be used as an alternative for treating perforated gastroduodenal ulcers. In this study, we evaluated the efficacy of percutaneous abdominal drainage for the conservative treatment of perforated gastroduodenal ulcers. We retrospectively studied 51 patients who had undergone conservative therapy for perforated gastroduodenal ulcers. These patients were divided into 2 groups on the basis of the initial treatment with conservative therapy with or without percutaneous drainage: group PD included patients who had undergone percutaneous drainage and group NPD, patients who had undergone non-percutaneous drainage. In the PD group, 14.3% (n=3) of the patients did not respond to conservative therapy, while this value was 43.3% (n=13) in the NPD group. The 2 groups differed significantly with respect to conversion from conservative therapy to surgery (pperforated gastroduodenal ulcers should be performed only in the case of patients meeting the required criteria; its combination with percutaneous intraperitoneal drainage is effective as initial conservative therapy.

  7. Influence of perforation erosion on multiple growing hydraulic fractures in multi-stage fracturing

    Directory of Open Access Journals (Sweden)

    Yongming Li

    2018-02-01

    Full Text Available In multi-stage hydraulic fracturing, the limited-entry method is widely used to promote uniform growth of multiple fractures. However, this method's effectiveness may be lost because the perforations will be eroded gradually during the fracturing period. In order to study the influence of perforation erosion on multiple growing hydraulic fractures, we combined the solid–fluid coupled model of hydraulic fracture growth with an empirical model of perforation erosion to implement numerical simulation. The simulations show clearly that the erosion of perforation will significantly deteriorate the non-uniform growth of multiple fractures. Based on the numerical model, we also studied the influences of proppant concentration and injection rates on perforation erosion in multi-stage hydraulic fracturing. The results indicate that the initial erosion rates become higher with the rising proppant concentration, but the growth of multiple hydraulic fractures is not sensitive to the varied proppant concentration. In addition, higher injection rates are beneficial significantly to the limited-entry design, leading to more uniform growth of fractures. Thus, in multi-stage hydraulic fracturing enough high injection rates are proposed to keep uniform growths. Keywords: Unconventional oil and gas reservoir, Horizontal well, Perforation friction, Perforation erosion, Multi-stage hydraulic fracturing, Numerical simulation, Mathematic model, Uniform growth of fractures

  8. Biliary peritonitis due to gall bladder perforation after percutaneous nephrolithotomy

    Directory of Open Access Journals (Sweden)

    Nikhil Ranjan

    2015-01-01

    Full Text Available A 19-year-old male patient underwent right percutaneous nephrolithotomy (PNL for right renal 1.5 × 1.5 cm lower pole stone. The procedure was completed uneventfully with complete stone clearance. The patient developed peritonitis and shock 48 h after the procedure. Exploratory laparotomy revealed a large amount of bile in the abdomen along with three small perforations in the gall bladder (GB and one perforation in the caudate lobe of the liver. Retrograde cholecystectomy was performed but the patient did not recover and expired post-operatively. This case exemplifies the high mortality of GB perforation after PNL and the lack of early clinical signs.

  9. Intraoperative Tumor Perforation is Associated with Decreased 5-Year Survival in Colon Cancer

    DEFF Research Database (Denmark)

    Bundgaard, N S; Bendtsen, V O; Ingeholm, P

    2017-01-01

    BACKGROUND: It is a widely held belief that intraoperative tumor perforation in colon cancer impairs survival and causes local recurrence, although the prognostic importance remains unclear. AIM: The aim of this study was to assess the effect of unintended intraoperative tumor perforation...... on postoperative mortality and long-term survival. MATERIAL AND METHODS: This national cohort study was based on data from a prospectively maintained nationwide colorectal cancer database. We included 16,517 colon cancer patients who were resected with curative intent from 2001 to 2012. RESULTS: Intraoperative...... tumor perforation produced a significantly impaired 5-year survival of 40% compared to 64% in non-perforated colon cancer. Intraoperative tumor perforation was an independent risk factor for death, hazard ratio 1.63 (95% confidence interval: 1.4-1.94), with a significantly increased 90-day postoperative...

  10. Study on modal characteristics of perforated shell using effective Young's modulus

    Energy Technology Data Exchange (ETDEWEB)

    Jhung, Myung Jo, E-mail: mjj@kins.re.kr [Korea Institute of Nuclear Safety, 19 Guseong-dong, Yuseong-gu, Daejeon 305-338 (Korea, Republic of); Yu, Seon Oh [Korea Institute of Nuclear Safety, 19 Guseong-dong, Yuseong-gu, Daejeon 305-338 (Korea, Republic of)

    2011-06-15

    Research highlights: > The effective Young's modulus of perforated shell is proposed for modal analysis. > The penetration pattern is almost negligible for effective elastic constants. > The frequency of perforated shell decreases significantly due to the hole effect. - Abstract: For the perforated cylindrical shell submerged in fluid, it is almost impossible to develop a finite element model due to the necessity of the fine meshing of the shell and the fluid at the same time. This necessitates the use of solid shell with effective material properties. Unfortunately the effective elastic constants are not found in any references even though the ASME code is suggesting those for perforated plate. Therefore in this study the effective material properties of perforated shell are suggested by performing several finite element analyses with respect to the ligament efficiencies.

  11. Malrotation with midgut volvulus associated with perforated ileal duplication

    Directory of Open Access Journals (Sweden)

    Anand Pandey

    2013-01-01

    Full Text Available Duplication of the alimentary tract is an important surgical condition. It may occur anywhere in the gastrointestinal tract. An important complication of this entity is perforation of the normal or abnormal gut. Malrotation with midgut volvulus can be a surgical emergency. We present a patient, who presented as malrotation with midgut volvulus associated with perforated ileal duplication. The patient was successfully managed.

  12. Spontaneous bile duct perforation in an infant, managed with simple ...

    African Journals Online (AJOL)

    Spontaneous bile duct perforation is a very rare but important cause of surgical jaundice in pediatric patients and one of the most common causes of surgical jaundice during infancy after biliary atresia. Preoperative diagnosis may not be possible in most of the cases. The exact cause of the perforation remains unclear.

  13. Experience with Acute Perforated Duodenal Ulcer in a West African ...

    African Journals Online (AJOL)

    Plain chest x-rays demonstrated gas under the diaphragm in 21(65.6%) of the patients. After adequate resuscitation, all the patients underwent laparotomy where the abdomen was explored, the diagnosis of perforated duodenal ulcer was confirmed and 29(70.7%) had simple closure of the perforation with omentum (after ...

  14. Ceramic microsieves: influence of perforation shape and distribution on flow resistance and membrane strength

    NARCIS (Netherlands)

    Kuiper, S.; Brink, R.; Nijdam, W.; Krijnen, Gijsbertus J.M.; Elwenspoek, Michael Curt

    2002-01-01

    Ceramic microsieves with slit-shaped perforations were compared to sieves with circular-shaped perforations, regarding flow resistance and membrane strength. Destructive tests show that the highest strength is obtained if the perforations are placed in a non-alternating pattern. Especially for

  15. Colorectal cancer with intestinal perforation - a retrospective analysis of treatment outcomes.

    Science.gov (United States)

    Banaszkiewicz, Zbigniew; Woda, Łukasz; Tojek, Krzysztof; Jarmocik, Paweł; Jawień, Arkadiusz

    2014-01-01

    Colorectal cancer (CRC) is one of the leading cause of death in European population. It progresses without any symptoms in the early stages or those clinical symptoms are very discrete. The aim of this study was a retrospective analysis of treatment outcomes in patients with colorectal cancer complicated with intestinal perforation. A retrospective analysis of patients urgently operated upon in our Division of General Surgery, because of large intestine perforation, from February 1993 to February 2013 has been made. Results were compared with a group of patients undergoing the elective surgery for colorectal cancer in the same time and Division. Intestinal perforation occurred more often in males (6.52% vs. 6.03%), patients with mucous component in histopathological examination (9.09% vs. 6.01%) and with clinicaly advanced CRC. Patients treated because of perforation had a five-fold higher 30 day mortality rate (9.09% vs. 1.83%), however long-term survival did not differ significantly in both groups. After resectional surgery in 874 patients an intestinal anastomosis was made. Anastomotic leakage was present in 23 (2.6%) patients. This complication occurred six-fold more frequently in a group of patients operated upon because of intestinal perforation (12.20% vs. 2.16%). In patients with CRC complicated with perforation of the colon in a 30-day observation significantly higher rate of complications and mortality was shown, whereas there was no difference in distant survival rates.

  16. Quality Management for Neutron Transmutation Doping of Silicon Ingot in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ki-Doo; Kim, Ji-Uk; Yun, Hwa-Kyung; Lim, Chul-Hong; Kim, Young-Chil; Kim, Myong-Seop; Park, Sang-Jun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2007-10-15

    By using this doping method, silicon semiconductors with extremely uniform dopant distributions can be produced, and this is the dominant advantage of NTD compared with a conventional chemical doping. Good uniformity of a dopant concentration is usually required for high power applications such as thyristor (SCR), IGBT, IGCT and GTO and for special sensors. Achieving an accurate neutron fluence corresponding to a target resistivity as well as a uniform irradiation is the prime target of a neutron irradiation for NTD. Generally, in order to reach an accurate neutron fluence, a real time neutron flux is monitored by a neutron detector such as a Self-powered Neutron Detector(SPND). And, after an irradiation, the total irradiation fluence is confirmed by measuring the absolute activity of a neutron activation sample that has been irradiated with a silicon ingot, and thus the SPND can be properly calibrated. Excellent irradiation uniformity and a high accuracy for a target neutron dose have been achieved from the early works of NTD. However, to maintain this excellent quality, the neutron irradiation fluence should be continuously modified and controlled. So, in this work, an activity to maintain the irradiation quality is introduced.

  17. Acoustic Liner Drag: Measurements on Novel Facesheet Perforate Geometries

    Science.gov (United States)

    Howerton, Brian M.; Jones, Michael G.

    2016-01-01

    Interest in characterization of the aerodynamic drag of acoustic liners has increased in the past several years. This paper details experiments in the NASA Langley Grazing Flow Impedance Tube to quantify the relative drag of several perforate-over-honeycomb liner configurations at flow speeds of centerline flow Mach number equals 0.3 and 0.5. Various perforate geometries and orientations are investigated to determine their resistance factors using a static pressure drop approach. Comparison of these resistance factors gives a relative measurement of liner drag. For these same flow conditions, acoustic measurements are performed with tonal excitation from 400 to 3000 hertz at source sound pressure levels of 140 and 150 decibels. Educed impedance and attenuation spectra are used to determine the impact of variations in perforate geometry on acoustic performance.

  18. Congenital Infantile Fibrosarcoma Causing Intestinal Perforation in a Newborn

    Directory of Open Access Journals (Sweden)

    Margarita Kaiser

    2017-01-01

    Full Text Available Congenital infantile fibrosarcoma (CIF is a rare malignant mesenchymal tumor and only 14 cases have been reported with gastrointestinal manifestation. We report about a female newborn delivered per emergency cesarean section at 34 weeks of gestation. Postnatally, she rapidly developed an acute abdomen and sonographic evidence of intestinal perforation requiring laparotomy on the first day of life. A perforated 2 × 3 cm sized spherical tumorous structure of the jejunum was identified. Due to unknown histopathology at this point and unclear resectional margins, she received a temporary ileostomy, which was closed two months later. Histopathology revealed a congenital intestinal fibrosarcoma without the characteristic ETV6-NTRK3 fusion transcript. In conclusion, this rare tumor must be considered as differential diagnosis of intestinal perforations in newborns.

  19. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation.

    Science.gov (United States)

    Limmer, Alexandra M; Clement, Zackariah

    2017-01-01

    Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient's caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.

  20. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation

    Directory of Open Access Journals (Sweden)

    Alexandra M. Limmer

    2017-01-01

    Full Text Available Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient’s caecum was decompressed in the emergency department using a needle under local anaesthetic. The patient subsequently underwent laparoscopic hernia repair and had an uncomplicated recovery. When conducted safely and with precision in an appropriate patient, percutaneous needle caecostomy can provide immediate symptom relief, reduce risk of caecal perforation, and allow a laparoscopic surgical approach.

  1. Perforated duodenal ulcer -a rare cause of acute abdomen in pregnancy.

    Science.gov (United States)

    Goel, Bharti; Rani, Jyotsna; Huria, Anju; Gupta, Pratiksha; Dalal, Usha

    2014-09-01

    Acute abdomen during pregnancy is a medico-surgical emergency demanding concerted, synchronized specialties approach of obstetrician, surgeon and gastroenterologist. Duodenal perforation is one of the rarer causes of acute abdomen in pregnancy. Here, we report a case of duodenal perforation with peritonitis in third trimester of pregnancy requiring surgical management. Our aim of reporting this case is to stress the physicians to keep the differential of duodenal perforation also in mind while dealing with cases of acute abdomen in pregnancy and to proceed with multidisciplinary approach for better feto-maternal outcome.

  2. Method for improving the electrostatics perforation pattern using power controlled discharges

    Energy Technology Data Exchange (ETDEWEB)

    Garzon, C; Miranda, E; GarcIa-Garcia, J [Departament d' Enginyeria Electronica, Universitat Autonoma de Barcelona, 08193 Bellaterra, Barcelona (Spain); Martinez-Cisneros, C; Alonso, J, E-mail: carolina.garzon@uab.cat [Departament de Quimica Analitica, Universitat Autonoma de Barcelona, 08193 Bellaterra, Barcelona (Spain)

    2011-06-23

    The aims of this work are to show the influence of adding a series resistance at the output of a discharge generator circuit and to point out that this component can be used to control the spark energy in electrostatic perforation systems. Analysis of the experimental results reveals that there exists a close connection between the resistor value and the obtained perforation pattern both in hole density and size. The use of a series resistor has a strong influence on the material porosity, which is an important industrial parameter for assessing the pattern perforation quality.

  3. Effect of neutron irradiation on the breakdown voltage of power MOSFET's

    International Nuclear Information System (INIS)

    Hasan, S.M.Y.; Kosier, S.L.; Schrimpf, R.D.; Galloway, K.F.

    1994-01-01

    The effect of neutron irradiation on power metal-oxide-semiconductor field effect transistor (power MOSFET) breakdown voltage has been investigated. Transistors with various breakdown voltage ratings were irradiated in a TRIGA nuclear reactor with cumulative fluence levels up to 5 x 10 14 neutrons/cm 2 (1 MeV equivalent). Noticeable increases in the breakdown voltages are observed in n-type MOSFET's after 10 13 neutrons/cm 2 and in p-type MOSFETs after 10 12 neutrons/cm 2 . An increase in breakdown voltage of as much as 30% is observed after 5 x 10 14 neutrons/cm 2 . The increase in breakdown voltage is attributed to the neutron-irradiation-induced defects which decrease the mean free path and trap majority carriers in the space charge region. The effect of positive trapped oxide charge due to concomitant gamma radiation and the effect of the termination structure on the increase in breakdown voltage are considered. An empirical model is presented to predict the value of the breakdown voltage as a function of neutron fluence

  4. Abdominal wall perforation in a patient with recurrent epithelial ovarian cancer after bevacizumab treatment

    Directory of Open Access Journals (Sweden)

    Efnan Algin

    2016-08-01

    Full Text Available Bowel perforation is a rare but well-described complication of bevacizumab, a VEGF monoclonal antibody. However, bevacizumab associated abdominal wall perforation is a more serious complication. In here, a patient with recurrent epithelial ovarian cancer developing both bowel and abdominal wall perforation after bevacizumab treatment is reported with review of the literature to point out the clinical significance of this rare complication. To our knowledge, this is the first case with bevacizumab associated abdominal wall perforation.

  5. Spontaneous neonatal gastrointestinal perforation: surgical or ...

    African Journals Online (AJOL)

    ... cases of spontaneous gastrointestinal perforation in neonates at the University of Benin Teaching Hospital, Benin City. The perinatal stress factors were caesarian delivery, prematurity and fetal distress due to prolonged obstructed labour.

  6. Bowel perforation in type IV vascular Ehlers-Danlos syndrome. A systematic review.

    Science.gov (United States)

    El Masri, H; Loong, T-H; Meurette, G; Podevin, J; Zinzindohoue, F; Lehur, P-A

    2018-05-01

    Spontaneous gastrointestinal (GI) perforation is a well-known complication occurring in patients suffering from Type IV vascular Ehlers-Danlos syndrome (EDS IV). The aim of the present study was to review the current literature on spontaneous GI perforation in EDS IV and illustrate the surgical management and outcome when possible. A systematic review of all the published data on EDS IV patients with spontaneous GI perforation between January 2000 and December 2015 was conducted using three major databases PUBMED, EMBASE, and Cochrane Central Register of Controlled Trails. References of the selected articles were screened to avoid missing main articles. Twenty-seven published case reports and four retrospective studies, including 31 and 527 cases, respectively, matched the search criteria. A case from our institution was added. Mean age was 26 years (range 6-64 years). The most frequent site of perforation was the colon, particularly the sigmoid, followed by small bowel, upper rectum, and finally stomach. The majority of cases were initially managed with Hartmann's procedure. In recurrent perforations, total colectomy was performed. The reperforation rate was considerably higher in the "partial colectomy with anastomosis" group than in the Hartmann group. Colonic perforation is the most common spontaneous GI perforation in EDS IV patients. An unexpected fragility of the tissues should raise the possibility of a connective tissue disorder and prompt further investigation with eventual management of these high-risk patients with a multidisciplinary team approach in dedicated centres. In the emergency setting, a Hartmann procedure should be performed.

  7. Anatomical study of the popliteal artery perforator-based propeller flap and its clinical application.

    Science.gov (United States)

    Onishi, Tadanobu; Shimizu, Takamasa; Omokawa, Shohei; Sananpanich, Kanit; Kido, Akira; Mahakkanukrauh, Pasuk; Tanaka, Yasuhito

    2018-05-30

    There is lack of anatomical information regarding cutaneous perforator of the popliteal artery and its connections with the descending branch of the inferior gluteal and profunda femoris arteries. We aimed to evaluate the anatomical basis of popliteal artery perforator-based propeller flap from the posterior thigh region and to demonstrate our experience utilizing this flap. Ten fresh cadaveric lower extremities were dissected following injection of a silicone compound into the femoral artery. We investigated the number, location, length, and diameter of cutaneous perforators of the popliteal artery. Based on the results, we treated three cases with a large soft tissue defect around the knee using popliteal artery perforator-based propeller flap. We found a mean of 1.9 cutaneous perforators arising from the popliteal artery with a mean pedicle length of 6 cm and a mean arterial internal diameter of 0.9 mm, which were located at an average of 4 cm proximal to the bicondylar line. The most distal perforator consistently arose along the small saphenous vein and connected proximally with concomitant artery of the posterior femoral cutaneous nerve, forming a connection with perforating arteries of the profunda femoris artery. A mean of 4.5 cutaneous perforators branched from the arterial connection sites. All clinical cases healed without any complications. The popliteal artery perforator-based propeller flap is reliable for reconstruction of soft tissue defects around the knee. The flap should include the deep fascia and concomitant artery along with the posterior femoral cutaneous nerve for maintaining the blood supply.

  8. Perfuração de Luvas durante Cirurgias Ginecológicas Glove Perforation during Gynecologic Surgeries

    Directory of Open Access Journals (Sweden)

    Eddie Fernando Candido Murta

    2000-05-01

    Full Text Available Objetivo: analisar a incidência de perfuração de luvas cirúrgicas durante atos operatórios ginecológicos. Métodos: estudo prospectivo de 454 luvas usadas em 65 procedimentos utilizando-se o método de pressão de água. Resultados: do total de 454 luvas examinadas, foram verificadas perfurações em 54 (11,9%, sendo estatisticamente significativo o maior número de perfurações em comparação ao grupo controle, uma (1,7% em 60 analisadas (pPurpose: to analyze the frequency of glove perforation during gynecologic surgeries. Methods: a prospective study of 454 gloves used in 65 surgeries by the water pressure method. Results: of a total of 454 gloves, 54 (11.9% had perforations. Comparison with the control group showed p<0.05 (chi² test, 1 (1.7% perforation in 60 gloves tested. Of the total of gloves used in 65 surgeries, 29 (44.6% had perforations, 44 (81% had one perforation and 10 (19% had more than one perforation. The two most common sites of perforations were the index finger, 20 (29.5% and the thumb, 14 (25.9%. Perforation was predominant in the left hand (72.1%. The surgeons were the members of the team with the greatest number of glove perforations. Total hysterectomy was the most frequent surgery in which glove perforations occurred (50% of the cases. Conclusion: the glove perforations occurred with relatively high frequency during gynecologic surgeries. The index finger of the left hand proved to be the most affected region. Among the members of the team, the highest percentage of glove perforations occurred in those of the surgeons. Total hysterectomy had the highest perforation rate.

  9. Right ventricular perforation by a passive-fixation pacemaker lead two weeks after implantation

    Directory of Open Access Journals (Sweden)

    Azeem S. Sheikh, BSc, MBBS, FCPS, MRCP

    2014-12-01

    Full Text Available Myocardial perforation is a rare complication of permanent pacemaker implantation. While most of the perforations occur at the time of implantation or within the first 24 h, delayed myocardial perforations are very rare. The clinical course is extremely variable with some patients presenting completely asymptomatic, while others can develop cardiac tamponade and haemodynamic instability. We report an unusual case of a subacute ventricular perforation caused by a passive-fixation lead two weeks after implantation and we successfully managed to extract the lead under local anaesthesia, without the patient undergoing surgery, as recommended in the previously published reports.

  10. The activation method for determining neutron spectra and fluences

    International Nuclear Information System (INIS)

    Hogel, J.; Vespalec, R.

    1980-01-01

    3 mm thick foils of 4 and 17 mm in diameter were used for measurements. NaI scintillation detectors 45 mm in diameter by 50 mm thick and 40 mm in diameter by 1 mm thick, and a Ge-Li spectrometer of 53 cm 3 in volume were used for gamma detection. A photopeak or a certain part of the integral spectrum was measured for each radionuclide. Computer code PIKAR was applied in automatic calculation of a simple gamma spectrum obtained using the semiconductor spectrometer. The FACT code was used for calculating foil activity. Codes SAND II and RFSP were used for neutron spectra unfolding. Ge-Li detector spectrometry was used for determining neutron fluence. Code FLUE was used for determining the mean value of neutron flux density and fluence. (J.P.)

  11. Photothermal IR spectroscopy with perforated membrane micromechanical resonators

    DEFF Research Database (Denmark)

    Kurek, Maksymilian

    -IR method. In order to overcome them, string resonators were replaced by membranes. A reliable sampling technique was maintained by adding perforation to membranes and thereby essentially getting membrane porous filters. Membranes gave also access to fully integrated magnetic transduction that allowed...... for significant shrinkage and simplification of the system. An analytical model of a locally heated membrane was developed and confirmed through FEM simulations. Then, low stress silicon nitride perforated membranes were fabricated and characterized using two different experimental setups that employed optical...

  12. Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Conijn, Mandy M.A.; Hendrikse, Jeroen; Takahara, Taro; Mali, Willem P.T.M. [University Medical Center Utrecht, Department of Radiology (Hp E 01.132), P.O. Box 85500, Utrecht (Netherlands); Zwanenburg, Jaco J.M. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Geerlings, Mirjam I. [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Luijten, Peter R. [University Medical Center Utrecht, Department of Radiology (Hp E 01.132), P.O. Box 85500, Utrecht (Netherlands); University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands)

    2009-12-15

    The aim of this study was to investigate the ability of time-of-flight (TOF) magnetic resonance (MR) angiography at 7.0 Tesla to show the perforating branches of the posterior communicating artery (PCoA), and to investigate the presence of such visible perforating branches in relation to the size of the feeding PCoA. The secondary aim was to visualise and describe the anterior choroidal artery and the perforating branches of the P1-segment of posterior cerebral artery (P1). Forty-six healthy volunteers underwent TOF MR angiography at 7.0 Tesla. With 7.0-Tesla imaging, we visualised for the first time perforating arteries originating from the PCoA in vivo without the use of contrast agents. A perforating artery from the PCoA was found in a large proportion of the PCoAs (64%). The presence was associated with a larger diameter of the underlying PCoA (1.23 versus 1.06 mm, P = 0.03). The anterior choroidal artery was visible bilaterally in all participants. In 83% of all P1s, one or two perforating branches were visible. Non-invasive assessment of the perforating arteries of the PCoA together with the anterior choroidal artery and the perforating arteries of the P1 may increase our understanding of infarcts in the deep brain structures supplied by these arteries. (orig.)

  13. Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study

    International Nuclear Information System (INIS)

    Conijn, Mandy M.A.; Hendrikse, Jeroen; Takahara, Taro; Mali, Willem P.T.M.; Zwanenburg, Jaco J.M.; Geerlings, Mirjam I.; Luijten, Peter R.

    2009-01-01

    The aim of this study was to investigate the ability of time-of-flight (TOF) magnetic resonance (MR) angiography at 7.0 Tesla to show the perforating branches of the posterior communicating artery (PCoA), and to investigate the presence of such visible perforating branches in relation to the size of the feeding PCoA. The secondary aim was to visualise and describe the anterior choroidal artery and the perforating branches of the P1-segment of posterior cerebral artery (P1). Forty-six healthy volunteers underwent TOF MR angiography at 7.0 Tesla. With 7.0-Tesla imaging, we visualised for the first time perforating arteries originating from the PCoA in vivo without the use of contrast agents. A perforating artery from the PCoA was found in a large proportion of the PCoAs (64%). The presence was associated with a larger diameter of the underlying PCoA (1.23 versus 1.06 mm, P = 0.03). The anterior choroidal artery was visible bilaterally in all participants. In 83% of all P1s, one or two perforating branches were visible. Non-invasive assessment of the perforating arteries of the PCoA together with the anterior choroidal artery and the perforating arteries of the P1 may increase our understanding of infarcts in the deep brain structures supplied by these arteries. (orig.)

  14. Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study.

    Science.gov (United States)

    Conijn, Mandy M A; Hendrikse, Jeroen; Zwanenburg, Jaco J M; Takahara, Taro; Geerlings, Mirjam I; Mali, Willem P Th M; Luijten, Peter R

    2009-12-01

    The aim of this study was to investigate the ability of time-of-flight (TOF) magnetic resonance (MR) angiography at 7.0 Tesla to show the perforating branches of the posterior communicating artery (PCoA), and to investigate the presence of such visible perforating branches in relation to the size of the feeding PCoA. The secondary aim was to visualise and describe the anterior choroidal artery and the perforating branches of the P1-segment of posterior cerebral artery (P1). Forty-six healthy volunteers underwent TOF MR angiography at 7.0 Tesla. With 7.0-Tesla imaging, we visualised for the first time perforating arteries originating from the PCoA in vivo without the use of contrast agents. A perforating artery from the PCoA was found in a large proportion of the PCoAs (64%). The presence was associated with a larger diameter of the underlying PCoA (1.23 versus 1.06 mm, P = 0.03). The anterior choroidal artery was visible bilaterally in all participants. In 83% of all P1s, one or two perforating branches were visible. Non-invasive assessment of the perforating arteries of the PCoA together with the anterior choroidal artery and the perforating arteries of the P1 may increase our understanding of infarcts in the deep brain structures supplied by these arteries.

  15. Semiconductor Manufacturing equipment introduction

    International Nuclear Information System (INIS)

    Im, Jong Sun

    2001-02-01

    This book deals with semiconductor manufacturing equipment. It is comprised of nine chapters, which are manufacturing process of semiconductor device, history of semiconductor manufacturing equipment, kinds and role of semiconductor manufacturing equipment, construction and method of semiconductor manufacturing equipment, introduction of various semiconductor manufacturing equipment, spots of semiconductor manufacturing, technical elements of semiconductor manufacturing equipment, road map of technology of semiconductor manufacturing equipment and semiconductor manufacturing equipment in the 21st century.

  16. Fatal Gastrointestinal Perforations in sudden death cases in Last 10 ...

    African Journals Online (AJOL)

    Pathology unit of University Malaya, Kuala Lumpur in the year 2006 by reviewing the autopsy reports. There were 61 cases of GIT perforation out of 5579 autopsies conducted during a period of ten years (1996-2005). The incidence rate of fatal gastrointestinal perforation was 1.09% during this period. Out of these 61 cases, ...

  17. Use of the TRIGA reactor for the study of neutron pulses effect on semiconductors

    International Nuclear Information System (INIS)

    Di Giorgio, A.; Gallo, G.

    1972-01-01

    For the analysis of the behavior and the response of Si crystal solid state semiconductor detectors to n-radiations and/or gamma pulsating fluxes, experiments are in progress for a long time, using TRIGA of the LENA Reactor. At first, it had been taken into consideration the possibility to use particle accelerators with which, taking advantage of several types of reactions, neutrons fluxes can be obtained with temporal distribution of remarkable interest in the field of the measures of resolution of the sensitive elements. But the possibility of using the accelerators in the field of n-fluxes radiometry appears to be limited as the flux modulators, the Klystron-Reflex ones, do not allow the operation in stable regime with frequencies of order lower than a 10 Hz limit. That causes a remarkable accumulation of heat in the detectors, at the higher radiation fluxes, than does not allow to determine the response range in a linear operation regime; moreover, it turns out to be difficult to obtain a wide energetic spectrum n-flux. The TRIGA reactor, on the contrary, is able to operate, as acknowledged, both at steady state, with variable powers up to 250 KW, and at pulse mode with variable peak powers up to 250 MW and with impulse width around 30 msec, and it's able to supply: elevated wide energetic spectrum n-fluxes; gamma mounts/impulse up to the values of the Mrad; reproducible single impulses; proportionality between n-fluxes and peak power; possibility to control the sensitivity of the detectors in thermal, epithermal and fast groups of the n-flux. Such performances assure an wide range of experimental research, particularly concerning the spectral analysis of the output signals of the detectors, possibly used as transducers in systems measuring n- and/or gamma-flux

  18. Management of a Small Paracentral Corneal Perforation Using Iatrogenic Iris Incarceration and Tissue Adhesive

    Directory of Open Access Journals (Sweden)

    Akira Kobayashi

    2012-07-01

    Full Text Available Background: Surgical intervention for corneal perforation is indicated when the anterior chamber does not reform within a short period of time. Herein, we report the successful management of a small paracentral corneal perforation using autologous iris incarceration and tissue adhesive. Case: A 41-year-old man developed a small paracentral corneal perforation (0.5 mm in size in the right eye, while the treating physician attempted to remove the residual rust ring after removal of a piece of metallic foreign body. Observations: The eye was initially managed with a bandage soft contact lens to ameliorate the aqueous leakage; however, without success. Iatrogenic iris incarceration of the wound was first induced, followed by application of cyanoacrylate tissue adhesive to the perforated site. As a result, the anterior chamber was immediately reformed and maintained. Complete corneal epithelialization of the perforation was achieved in 2 months without visual compromises. Conclusions: Cyanoacrylate tissue adhesive with iatrogenic incarceration of the autologous iris was effective in treating this type of small corneal perforation. This technique is simple and potentially useful for small paracentral corneal perforations outside the visual axis and without good apposition.

  19. [Operative laparoscopy in the management of perforated peptic ulcer].

    Science.gov (United States)

    Schirru, Angelo; Cavaliere, Davide; Caristo, Ilario; Bianchi, Massimo; Cosce, Umberto; Mariani, Federica; Scarimbolo, Monica; Cavaliere, Paolo

    2004-01-01

    The aim of this retrospective study was to assess the feasibility, safety and efficacy of the laparoscopic approach in the management of perforated peptic ulcers. From January 1997 to December 2002, all patients referred to our community hospital for abdominal surgical emergencies were routinely managed by laparoscopic surgery. A review was carried out on 39 consecutive patients suffering from perforated peptic ulcers with or without generalised peritonitis. The study population comprised 24 male and 15 female patients, aged 30 to 94 years (mean age: 62 +/- 18). Laparoscopic repair was attempted in all patients. Laparoscopy afforded the correct diagnosis in all cases. Laparoscopic peritoneal washout (irrigation and suction of the entire abdominal cavity) with simple suture of the perforation proved successful in 34 patients. An additional omental patching was performed in 15 of these cases. Conversion to conventional open surgery was necessary in 5 patients. The morbidity and mortality rates were 13% and 10%, respectively. The mean operative time was 77 minutes (range: 40-120) and the mean hospital stay 9 days (range: 3-22). Laparoscopic repair of perforated ulcers is technically feasible but requires sound experience in laparoscopic abdominal emergencies. This study shows that the mini-invasive procedure is safe and effective, offering a valid alternative to traditional laparotomy.

  20. Radiation doping methods of semiconductor materials: the nuclear doping by charged particles

    International Nuclear Information System (INIS)

    Kozlovskii, V.V.; Zakharenkov, L.F.

    1996-01-01

    A review is given of the state of the art in one of the current topics in radiation doping of semiconductors, which is process of nuclear transmutation doping (NTD) by charged particles. In contrast to the neutron and photonuclear transmutation doping, which have been dealt with in monograths and reviews, NTD caused by the action of charged particles is a subject growing very rapidly in the last 10-15 years, but still lacking systematic accounts. The review consists of three sections. The first section deals with the characteristics of nuclear reactions in semiconductors caused by the action of charged particles: the main stress is on the modeling of NTD processes in semiconductors under the action of charged particles. In the second section the state of the art of experimental investigations of NTD under the influence of charged particles is considered. An analysis is made of the communications reporting experimental data on the total numbers of dopants which are introduced, concentration of the electrically active fraction of the impurity, profiles of the dopant distributions, and conditions for efficient annealing of radiation defects. The third section deals with the suitability of NTD by charged particles for the fabrication of semiconductor devices. (author)

  1. Primary Report of Totally Tubeless Percutaneous Nephrolithotomy Despite Pelvi-calyceal Perforations.

    Science.gov (United States)

    Aghamir, Seyed Mohammad Kazem; Salavati, Alborz; Hamidi, Morteza; FallahNejad, Asghar

    2017-07-02

    Nephrostomy tube insertion and/or a ureteral stent placement is advised when pelvi-calyceal perforations are encountered during percutaneous nephrolithotomy (PNL) nevertheless totally tubeless PNL is a possible exit strategy in percutaneous renal surgery therefore case series on the short term clinical outcomes of noninvasive management of iatrogenic pelvicalyceal perforations encountered during PNL is presented. During retrospective analysis of 1271 PNL procedures, 25 incidents of accidental ureteral catheter/ jj stent dislodgement during first 24 post-operative hours were identified in patient who had pelvi calyceal perforations and had no nephrostomy tube (tubeless). Thirteen patients could not be re-stented nor a nephrostomytube could have been placed for them mainly due to patient refusal or comorbid conditions. The main outcome was rate of successful noninvasive management. Eighteen Patients bearing mucosal tears (grade I trauma) or visible peri-pelvic fat (grade II) successfully recovered without need for ureteral stenting or nephrostomy (72.0%). In seven (28.0%) cases of extension of the perforation into the peri-pelvic fat (grade III), either nephrostomy insertion or JJ stenting was needed for resolution of fever and urinoma. The major limitation was the necessity to exclude patients and manage them in the standard fashion according to clinical guidelines. Iatrogenic perforations of the collecting system are quite diverse in terms of severity that result in different natural histories and not all might need urinary diversion via nephrostomy or ureteral stenting.Low grade perforations may be successfully managed in totally tubeless fashion nevertheless further prospective investigations seem warranted.

  2. Management of nontraumatic corneal perforation with tectonic drape patch and cyanoacrylate glue.

    Science.gov (United States)

    Khalifa, Yousuf M; Bailony, M Rami; Bloomer, Michele M; Killingsworth, Daniel; Jeng, Bennie H

    2010-10-01

    To report a case of nontraumatic corneal perforation managed with a tectonic drape patch. Interventional case report. A 60-year-old patient with a corneal scar in his left eye likely secondary to herpes simplex virus interstitial keratitis underwent laser peripheral iridotomy for narrow angles. He developed progressive thinning of the cornea overlying the scar that led to a descemetocele and then ultimately a 1.2- × 1.7-mm perforation. Intraoperatively, several attempts were made to seal the perforation with cyanoacrylate glue, but the wound continued to leak. Sterile plastic drape that was on the surgical field was fashioned into a 2-mm-diameter patch, and the peripheral edge of the tectonic drape patch was glued over the perforation, successfully sealing the cornea. One week later, the drape patch was intact without leak, and a penetrating keratoplasty was carried out without complication. Tectonic drape patch technique for nontraumatic corneal perforations in which there is tissue loss is a viable temporizing option when cyanoacrylate glue alone fails and when there is no corneal tissue or amniotic membrane available to close the wound.

  3. Perforation and bacterial contamination of microscope covers in lumbar spinal decompressive surgery.

    Science.gov (United States)

    Osterhoff, Georg; Spirig, José; Klasen, Jürgen; Kuster, Stefan P; Zinkernagel, Annelies S; Sax, Hugo; Min, Kan

    2014-01-01

    To determine the integrity of microscope covers and bacterial contamination at the end of lumbar spinal decompressive surgery. A prospective study of 25 consecutive lumbar spinal decompressions with the use of a surgical microscope was performed. For detection of perforations, the microscope covers were filled with water at the end of surgery and the presence of water leakage in 3 zones (objective, ocular and control panel) was examined. For detection of bacterial contamination, swabs were taken from the covers at the same locations before and after surgery. Among the 25 covers, 1 (4%) perforation was observed and no association between perforation and bacterial contamination was seen; 3 (4%) of 75 smears from the 25 covers showed post-operative bacterial contamination, i.e. 2 in the ocular zone and 1 in the optical zone, without a cover perforation. The incidence of microscope cover perforation was very low and was not shown to be associated with bacterial contamination. External sources of bacterial contamination seem to outweigh the problem of contamination due to failure of cover integrity. © 2014 S. Karger AG, Basel.

  4. Gastro-duodenal perforations: conventional plain film, US and CT findings in 166 consecutive patients

    International Nuclear Information System (INIS)

    Grassi, Roberto; Romano, Stefania; Pinto, Antonio; Romano, Luigia

    2004-01-01

    Introduction: Gastro-duodenal perforations may be suspected in patients with history of ulceration, who present with acute pain and abdominal wall rigidity, but radiological findings in these cases may be unable to confirm a clinical diagnosis. The aim of our study was to report our experience in the diagnosis of gastro-duodenal perforation by conventional radiography, US and CT examinations. Material and methods: We retrospectively reviewed medical records of 166 consecutive patients who presented in the last 2 years to our institutions with symptoms of acute abdomen and submitted to surgery at the Emergency Unit of the ''A.Cardarelli'' Hospital of Naples with a surgical finding of perforated gastro-duodenal ulcer. The evidence of free intraperitoneal air on abdominal plain film was considered as a direct or suggestive finding of perforation. Evidence of intraperitoneal free fluid and/or reduced intestinal peristalsis at sonographic examination were considered indirect signs of gastro-duodenal perforation. Evidence of free peritoneal gas at CT was considered as a direct evidence of gastro-duodenal perforation. Results: Twenty patients underwent immediate surgery with no preoperative imaging evaluation, in 10 of them the site of perforation was found in a juxta-pyloric region and in the others at level of duodenum. In 146 patients submitted to serial radiological investigations before surgery, the site of perforation was in 56 (38.3%) duodenal, in 52 (35.6%) juxta-pyloric, in 28 (19.1%) gastric and in 10 (6.8%) pyloric. The cause of perforation was in all cases gastric or duodenal ulceration, in seven cases involving pancreatic parenchyma. In 110 (75.4%) patients with direct findings of perforation, in 94 cases (85.5%) the correct diagnosis was established on abdominal plain film, in two (1.8%) with radiographic and sonographic examinations and in 14 (12.7%) on CT findings. In 36 (24,6%) patients with no direct findings of perforation, only 24 (16,4%) of them

  5. Gastro-duodenal perforations: conventional plain film, US and CT findings in 166 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Grassi, Roberto; Romano, Stefania E-mail: stefromano@libero.it; Pinto, Antonio; Romano, Luigia

    2004-04-01

    Introduction: Gastro-duodenal perforations may be suspected in patients with history of ulceration, who present with acute pain and abdominal wall rigidity, but radiological findings in these cases may be unable to confirm a clinical diagnosis. The aim of our study was to report our experience in the diagnosis of gastro-duodenal perforation by conventional radiography, US and CT examinations. Material and methods: We retrospectively reviewed medical records of 166 consecutive patients who presented in the last 2 years to our institutions with symptoms of acute abdomen and submitted to surgery at the Emergency Unit of the ''A.Cardarelli'' Hospital of Naples with a surgical finding of perforated gastro-duodenal ulcer. The evidence of free intraperitoneal air on abdominal plain film was considered as a direct or suggestive finding of perforation. Evidence of intraperitoneal free fluid and/or reduced intestinal peristalsis at sonographic examination were considered indirect signs of gastro-duodenal perforation. Evidence of free peritoneal gas at CT was considered as a direct evidence of gastro-duodenal perforation. Results: Twenty patients underwent immediate surgery with no preoperative imaging evaluation, in 10 of them the site of perforation was found in a juxta-pyloric region and in the others at level of duodenum. In 146 patients submitted to serial radiological investigations before surgery, the site of perforation was in 56 (38.3%) duodenal, in 52 (35.6%) juxta-pyloric, in 28 (19.1%) gastric and in 10 (6.8%) pyloric. The cause of perforation was in all cases gastric or duodenal ulceration, in seven cases involving pancreatic parenchyma. In 110 (75.4%) patients with direct findings of perforation, in 94 cases (85.5%) the correct diagnosis was established on abdominal plain film, in two (1.8%) with radiographic and sonographic examinations and in 14 (12.7%) on CT findings. In 36 (24,6%) patients with no direct findings of perforation, only 24

  6. Hollow organ perforation in blunt abdominal trauma: the role of diagnostic peritoneal lavage.

    Science.gov (United States)

    Wang, Yu-Chun; Hsieh, Chi-Hsun; Fu, Chih-Yuan; Yeh, Chun-Chieh; Wu, Shih-Chi; Chen, Ray-Jade

    2012-05-01

    With recent advances in radiologic diagnostic procedures, the use of diagnostic peritoneal lavage (DPL) has markedly declined. In this study, we reviewed data to reevaluate the role of DPL in the diagnosis of hollow organ perforation in patients with blunt abdominal trauma. Adult patients who had sustained blunt abdominal trauma and who were hemodynamically stable after initial resuscitation underwent an abdominal computed tomographic (CT) scan. Diagnostic peritoneal lavage was performed for patients who were indicated to receive nonoperative management and where hollow organ perforation could not be ruled out. During a 60-month period, 64 patients who had received abdominal CT scanning underwent DPL. Nineteen patients were diagnosed as having a positive DPL based on cell count ratio of 1 or higher. There were 4 patients who sustained small bowel perforation. The sensitivity and specificity of the cell count ratio for a hollow organ perforation in this study were 100% and 75%, respectively. No missed hollow organ perforations were detected. For patients with blunt abdominal trauma and hemoperitoneum who plan to receive nonoperative management, DPL is still a useful tool to exclude hollow organ perforation that is undetected by CT. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Combined esophageal injury complicated by progression to a second perforation: a case report

    Directory of Open Access Journals (Sweden)

    Krieg Andreas

    2009-09-01

    Full Text Available Abstract Introduction Intramural dissection of the esophagus is a rare disorder characterized by a lesion between the submucosa and mucosa dividing the esophagus into a false and true lumen. The etiology of esophageal dissection remains uncertain but it affects predominantly women in their seventies and eighties. Symptoms may include uncharacteristic ones such as retrosternal pain, odynophagia or dysphagia. Conservative management is thought to be adequate and surgery should only be performed if complications such as abscess formation or perforation appear. Here we report the case and surgical management of a combined esophageal perforation and dissection. Case presentation We report the case of a combined esophageal perforation and dissection in a 45-year-old Caucasian woman with a history of relapsing periods of dysphagia since her childhood. The clinical course in this patient was complicated by progression to a second perforation, which made a definitive surgical management by esophagectomy necessary. Conclusion To the best of our knowledge, this is the first reported case of a combined esophageal perforation and dissection complicated by progression to a second perforation. This emphasizes that cautious and intensive observation is necessary in patients with esophageal dissection.

  8. Oral antibiotics for perforated appendicitis is not recommended

    DEFF Research Database (Denmark)

    Alamili, Mahdi; Gögenur, Ismail; Rosenberg, Jacob

    2010-01-01

    In the majority of surgical departments in Denmark, the postoperative treatment for acute perforated appendicitis comprises three days of intravenous antibiotics. Recently, it has been proposed that such antibiotic regimen should be replaced by orally administered antibiotics. The aim of this paper...... was to give an overview of studies on acute perforated appendicitis with postoperative oral antibiotics. Five studies were found in a database search covering the 1966-2009 period. There is no evidence to support a conversion of the postoperative antibiotic regimen from intravenous to oral administration...

  9. Perforated Peptic Ulcer: new insights

    NARCIS (Netherlands)

    M.J.O.E. Bertleff (Marietta)

    2011-01-01

    textabstractMuch has been written on perforated peptic ulcer (PPU) during the last hundred years. In 1500, when necropsies were first allowed, often a small hole was found in the anterior wall of the stomach, giving an explanation for symptoms of acute abdominal pain, nausea, vomiting which often

  10. Repair of an Endoscopic Retrograde Cholangiopancreatography-Related Large Duodenal Perforation Using Double Endoscopic Band Ligation and Endoclipping

    Directory of Open Access Journals (Sweden)

    Keunmo Kim

    2017-03-01

    Full Text Available Endoscopic closure techniques have been introduced for the repair of duodenal wall perforations that occur during endoscopic retrograde cholangiopancreatography (ERCP. We report a case of successful repair of a large duodenal wall perforation by using double endoscopic band ligation (EBL and an endoclip. Lateral duodenal wall perforation occurred during ERCP in a 93-year-old woman with acute calculous cholangitis. We switched to a forward endoscope that had a transparent band apparatus. A 2.0-cm oval-shaped perforation was found at the lateral duodenal wall. We repaired the perforation by sequentially performing double EBL and endoclipping. The first EBL was performed at the proximal edge of the perforation orifice, and two-thirds of the perforation were repaired. The second EBL, which also included the contents covered under the first EBL, repaired the defect almost completely. Finally, to account for the possible presence of a residual perforation, an endoclip was applied at the distal end of the perforation. The detection and closure of the perforation were completed within 10 minutes. We suggest that double EBL is an effective method for closure.

  11. Comparative research of finite element methods for perforated structures of nuclear power plant primary equipment

    International Nuclear Information System (INIS)

    Xiong Guangming; Deng Xiaoyun; Jin Ting

    2013-01-01

    Many perforated structures are used for nuclear power plant primary equipment, and they are complex, and have various forms. In order to explore the analysis and evaluation method, this paper used finite element method and equivalent analytic method to do the comparative analysis of perforated structures. The paper considered the main influence factors (including perforated forms, arrangements, and etc.), obtaining the systematic analysis methods of perforated structures. (authors)

  12. The Effect of Perforation on the Dynamics of a Flexible Panel

    Directory of Open Access Journals (Sweden)

    A. Putra

    2014-01-01

    Full Text Available Introduction of holes into plate-like structures is commonly found as one of the practical noise control measures to reduce sound radiation. However, perforation also reduces the panel stiffness and hence increases its vibration. The discussion on this effect is lacking and hence this paper discusses the dynamics of a perforated panel from the results obtained from Finite Element (FE model. Different hole geometries and arrangement are simulated to investigate their effect on the plate mobility. In general, it is found that increasing the perforation ratio increases the plate mobility. For a fixed perforation ratio, the mobility increases at high frequency (above 1 kHz for a smaller hole density in the plate. The plate with holes concentrated at the middle shows the largest increase of vibration around the plate centre compared to those uniformly distributed or away from the middle and concentrated at the plate edges. This is because as the hole separation becomes smaller, the reduction of the global stiffness around the mid area of the plate becomes greater. This also corresponds to the finding here that the mobility is greater at the vicinity of the hole. Different conditions of the plate edges are found to give consistent trend of the effect of perforation.

  13. Investigation of efficient termination structure for improved breakdown properties of semiconductor radiation detectors

    International Nuclear Information System (INIS)

    Krizaj, D.; Resnik, D.; Vrtacnik, D.; Amon, S.

    1998-01-01

    Efficiency of a new junction termination structure for improvement of breakdown properties of semiconductor radiation detectors is investigated. The structure consists of a diffused resistor winding around the active junction in a spiral fashion. The current flow through the spiral enables controlled potential distribution along the spiral turns and thus controlled depletion spreading from the main junction, efficiently preventing premature avalanche breakdown. Both multiple guard-ring structures and spiral junction termination structures have shown good breakdown properties typically three to five times higher than breakdown voltages of diodes without junction termination. The breakdown voltages of spiral junction termination structures are only weakly influenced by changes in substrate doping concentration caused by neutron irradiation. They can thus be considered for termination of future semiconductor radiation detectors

  14. Vinorelbine induced perforation of a metastatic gastric lesion.

    Science.gov (United States)

    Mullally, W J; O'Súilleabháin, C B; Brady, C; O'Reilly, S

    2017-08-01

    Breast carcinoma metastasis to the gastrointestinal tract is rare and more frequently associated with lobular than ductal carcinoma (Borst and Ingold, Surg 114(4):637-641 [1]). The purpose of this article is to present a case based review of a unique gastrointestinal metastasis and literature review. A 46 year old lady with metastatic invasive ductal breast cancer was admitted to A&E with sudden onset of epigastric and left shoulder pain. She completed the first cycle of capecitabine/vinorelbine 1 week previously. Clinical examination revealed a tender epigastrium with rigidity in the upper abdomen. Free air under the diaphragm and a positive Rigler's sign was radiologically identified. A laparoscopy demonstrated a fibrinous exudate in the left upper quadrant consistent with a walled off lesser curvature gastric perforation. A subsequent oesophagogastroduodenoscopy (OGD) demonstrated a healed gastric ulcer of benign appearance; however the pathology confirmed metastatic breast carcinoma. Literature review confirmed no previously reported cases of vinorelbine induced gastric perforation. Four cases of metastatic breast cancer with gastric metastasis presenting with perforation were identified; three of these cases (Fra et al., Presse Med 25(26):1215 (1996) [2], Solis-Caxaj et al., Gastroenterol Clin Biol 28(1):91-92 (2004) [3], Ghosn et al., Bull Cancer 78(11):1071-1073 (1991) [4]), were in the French medical literature, including one male patient (Fra et al., Presse Med 25(26):1215 (1996) [2]) and at least one ductal breast carcinoma (Solis-Caxaj et al., Gastroenterol Clin Biol 28(1):91-92 (2004) [3]). The fourth case (van Geel et al., Ned Tijdschr Geneeskd 144(37):1761-1763 (2000) [5]), was in the Dutch medical literature and a lobular breast carcinoma. This case represents a rare complication of breast cancer chemotherapy, the subsequent significant benefit the patient received from treatment is consistent with the chemosensitivity to therapy that also resulted

  15. Neutron scattering study of Ce3Au3Sb4

    International Nuclear Information System (INIS)

    Kasaya, Mitsuo; Katoh, Kenichi; Kohgi, Masahumi; Osakabe, Toyotaka

    1993-01-01

    Rare-earth compounds with an Y 3 Au 3 Sb 4 -type crystal structure are semiconductors or semi-metals. Among them, Ce 3 Au 3 Sb 4 is a semiconductor with an activation energy of about 640 K and shows no magnetic order down to 1.5 K. The magnetic part of the specific heat for Ce 3 Au 3 Sb 4 obtained by subtracting the value for La 3 Au 3 Sb 4 from the total specific heat of Ce 3 Au 3 Sb 4 shows a broad peak at around 10 K, the origin of which is well explained by the crystalline-field splitting determined by neutron scattering. (author)

  16. Mesenchymal stem cell-laden hybrid scaffold for regenerating subacute tympanic membrane perforation

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Chul Ho, E-mail: chulsavio@hanmail.net [Department of Otolaryngology, Chonnam National University Medical School, Gwangju (Korea, Republic of); Ahn, SeungHyun [Department of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon (Korea, Republic of); Lee, Jae Whi; Lee, Byeong Ha [School of Information and Communications, Gwangju Institute of Science and Technology, Gwangju (Korea, Republic of); Lee, Hyeongjin [Department of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon (Korea, Republic of); Kim, GeunHyung, E-mail: gkimbme@skku.edu [Department of Biomechatronic Engineering, College of Biotechnology and Bioengineering, Sungkyunkwan University, Suwon (Korea, Republic of)

    2017-03-01

    Tympanic membrane (TM) perforation is one of the most common otology complications. To date, there has not been reported TM regeneration using bioprinted scaffold. The purpose of this study was to evaluate the efficacy and feasibility of bioprinted polycaprolactone/collagen/alginate-mesenchymal stem cell (PCAMSC) scaffolds for the regeneration of subacute TM perforation. Sprague-Dawley rats were used in an animal model of subacute TM perforation. In the experimental group (n = 7), bioprinted 3D PCAMSC scaffold was placed on the perforation. The control group (n = 7) were treated with polycaprolactone/collagen/alginate (PCA) scaffold. Healing time, acoustic-mechanical properties, and morphological analysis were performed by otoendoscopy, auditory brainstem response (ABR), single-point laser doppler vibrometer (LDV), optical coherence tomography (OCT), and light microscopic evaluation. The closure of the TM perforation was achieved in 100% of the experimental group vs. 72% of the control group, and this difference was statistically significant (p < 0.05). The ABR threshold at all frequencies of the experimental group was recovered to the normal level compared to the control group. TM vibration velocity in the experimental group recovered similar to the normal control level. The difference are very small and they are not statistically significant below 1 kHz (p = 0.074). By OCT and light microscopic examination, regenerated TM of the experimental group showed thickened fibrous and mucosal layer. In contrast, the control group showed well regenerated but less thickened than experimental group. From these results, the cell-laden PCAMSC scaffold offers a significant advantage in the TM regeneration in a rat subacute TM perforation model. It may offer attractive opportunities in the conservative clinical treatment. - Highlights: • MSCs-laden scaffold was fabricated using a centrifugal spinning and cell-printing process. • The cell-laden scaffold showed the outstanding

  17. Mesenchymal stem cell-laden hybrid scaffold for regenerating subacute tympanic membrane perforation

    International Nuclear Information System (INIS)

    Jang, Chul Ho; Ahn, SeungHyun; Lee, Jae Whi; Lee, Byeong Ha; Lee, Hyeongjin; Kim, GeunHyung

    2017-01-01

    Tympanic membrane (TM) perforation is one of the most common otology complications. To date, there has not been reported TM regeneration using bioprinted scaffold. The purpose of this study was to evaluate the efficacy and feasibility of bioprinted polycaprolactone/collagen/alginate-mesenchymal stem cell (PCAMSC) scaffolds for the regeneration of subacute TM perforation. Sprague-Dawley rats were used in an animal model of subacute TM perforation. In the experimental group (n = 7), bioprinted 3D PCAMSC scaffold was placed on the perforation. The control group (n = 7) were treated with polycaprolactone/collagen/alginate (PCA) scaffold. Healing time, acoustic-mechanical properties, and morphological analysis were performed by otoendoscopy, auditory brainstem response (ABR), single-point laser doppler vibrometer (LDV), optical coherence tomography (OCT), and light microscopic evaluation. The closure of the TM perforation was achieved in 100% of the experimental group vs. 72% of the control group, and this difference was statistically significant (p < 0.05). The ABR threshold at all frequencies of the experimental group was recovered to the normal level compared to the control group. TM vibration velocity in the experimental group recovered similar to the normal control level. The difference are very small and they are not statistically significant below 1 kHz (p = 0.074). By OCT and light microscopic examination, regenerated TM of the experimental group showed thickened fibrous and mucosal layer. In contrast, the control group showed well regenerated but less thickened than experimental group. From these results, the cell-laden PCAMSC scaffold offers a significant advantage in the TM regeneration in a rat subacute TM perforation model. It may offer attractive opportunities in the conservative clinical treatment. - Highlights: • MSCs-laden scaffold was fabricated using a centrifugal spinning and cell-printing process. • The cell-laden scaffold showed the outstanding

  18. Mounting and testing of a 'sandwich' type neutron spectrometer with semiconductor detectors and 6Li

    International Nuclear Information System (INIS)

    Fabro, M.A.

    1973-01-01

    Commercial surface barrier detectors (Si(Au)) were used to construct the spectrometer; the 6 LiF was evaporated by vacuum onto a film of Formvar and afterwards over the surface of one of the detectors, with a 6 LiF thickness of 0,2 μm (50 μg/cm 2 ) and 1,5 μm(400 μg/cm 2 ) respectively. Tests were made with slow neutrons and with neutrons from the reactions D(d,n) 3 He (2,65 MeV) and T(d,n) 4 He (14 MeV). The energy resolution for thermal neutrons was about 200 keV (FWHM) for the sum (E sub(t) + E sub(α)) and about 7 keV (FWHM) for the difference (E sub(t) - E sub(α)) with an evaluated efficiency of 5,5x10 -4 , for the sum. For the 2,65 MeV neutrons, the energy resolution was about 240 keV (FWHM) and an evaluated efficiency of 2,1 x 10 -7 . It was not possible to detect 14 MeV neutrons [pt

  19. Study of PIN diode energy traps created by neutrons

    International Nuclear Information System (INIS)

    Sopko, V; Dammer, J; Sopko, B; Chren, D

    2013-01-01

    Characterization of radiation defects is still ongoing and finds greater application in the increasing radiation doses on semiconductor detectors in experiments. Studying the changes of silicon PIN diode for high doses of radiation is the fundamental motivation for our measurements. In this article we describe the behavior of the PIN diode and development of the disorder caused by neutrons from a 252Cf and doses up to 8 Gy. The calibration curve for PIN diode shows the effect of disorders as the changes of the voltampere characteristics depending on the dose of neutron irradiation. The measured values for defects are in good agreement with created energy traps.

  20. Ultrasound and Perforated Viscus; Dirty Fluid, Dirty Shadows, and Peritoneal Enhancement

    Directory of Open Access Journals (Sweden)

    Hamid Shokoohi

    2016-04-01

    Full Text Available Early detection of free air in the peritoneal cavity is vital in diagnosis of life-threatening emergencies, and can play a significant role in expediting treatment. We present a series of cases in which bedside ultrasound (US in the emergency department accurately identified evidence of free intra-peritoneal air and echogenic (dirty free fluid consistent with a surgical final diagnosis of a perforated hollow viscus. In all patients with suspected perforated viscus, clinicians were able to accurately identify the signs of pneumoperitoneum including enhanced peritoneal stripe sign (EPSS, peritoneal stripe reverberations, and focal air collections associated with dirty shadowing or distal multiple reflections as ring down artifacts. In all cases, hollow viscus perforation was confirmed surgically. It seems that, performing US in patients with suspected perforated viscus can accurately identify presence of intra-peritoneal echogenic or “dirty” free fluid as well as evidence of free air, and may expedite patient management.

  1. Acute abdominal compartment syndrome complicating a colonoscopic perforation: a case report

    Directory of Open Access Journals (Sweden)

    Souadka Amine

    2012-02-01

    Full Text Available Abstract Introduction A perforation occurring during colonoscopy is an extremely rare complication that may be difficult to diagnose. It can be responsible for acute abdominal compartment syndrome, a potentially lethal complex pathological state in which an acute increase in intra-abdominal pressure may provoke the failure of several organ systems. Case presentation We report a case of acute abdominal compartment syndrome after perforation of the bowel during a colonoscopy in a 60-year-old North African man with rectal cancer, resulting in respiratory distress, cyanosis and cardiac arrest. Our patient was treated by needle decompression after the failure of cardiopulmonary resuscitation. An emergency laparotomy with anterior resection, including the perforated sigmoid colon, was then performed followed by immediate anastomosis. Our patient remains alive and free of disease three years later. Conclusion Acute abdominal compartment syndrome is a rare disease that may occasionally occur after a colonoscopic perforation. It should be kept in mind during colonoscopy, especially considering its simple salvage treatment.

  2. Nuclear radiation detectors using high resistivity neutron transmutation doped silicon

    International Nuclear Information System (INIS)

    Gessner, T.; Irmer, K.

    1983-01-01

    A method for the production of semiconductor detectors based on high resistivity n-type silicon is described. The n-type silicon is produced by neutron irradiation of p-type silicon. The detectors are produced by planar technique. They are suitable for the spectrometry of alpha particles and for the pulse count measurement of beta particles at room temperature. (author)

  3. Feasibility study of a SiC sandwich neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jian, E-mail: caepwujian@163.com [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province (China); Lei, Jiarong, E-mail: jiarong_lei@163.com [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province (China); Jiang, Yong; Chen, Yu; Rong, Ru; Zou, Dehui; Fan, Xiaoqiang [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province (China); Chen, Gang; Li, Li; Bai, Song [Nanjing Electronic Devices Institute, Nanjing 210016 (China)

    2013-04-21

    Semiconductor sandwich neutron spectrometers are suitable for in-pile measurements of fast reactor spectra thanks to their compact and relatively simple design. We have assembled and tested a sandwich neutron spectrometer based on 4H-silicon carbide (4H-SiC) Schottky diodes. The SiC diodes detect neutrons via neutron-induced charged particles (tritons and alpha particles) produced by {sup 6}Li(n,α){sup 3}H reaction. {sup 6}LiF neutron converter layers are deposited on the front surface of Schottky diodes by magnetron sputtering. The responses of SiC diodes to charged particles were investigated with an {sup 241}Am alpha source. A sandwich neutron spectrometer was assembled with two SiC Schottky diodes selected based on the charged-particle-response experimental results. The low-energy neutron response of the sandwich spectrometer was measured in the neutron field of the Chinese Fast Burst Reactor-II (CFBR-II). Spectra of alpha particles and tritons from {sup 6}Li(n,α){sup 3}H reaction were obtained with two well-resolved peaks. The energy resolution of the sum spectrum was 8.8%. The primary experimental results confirmed the 4H-SiC sandwich neutron spectrometer's feasibility. -- Highlights: ► Sandwich neutron spectrometer employing 4H-SiC as a detecting material has been developed for the first time. ► {sup 6}LiF neutron converter has been deposited on the surface of 4H-SiC Schottky diode. ► Preliminary testing results obtained with the 4H-SiC sandwich neutron spectrometer are presented.

  4. Improved productivity justifies world record underbalanced perforating operation

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, A. M.; Bakker, E. R. [NAM B.V. (Netherlands); Hungerford, K.

    1998-12-31

    To achieve vertical connectivity with all the layers, and thus long term sustained productivity in a highly stratified reservoir, a one run underbalanced perforating operation was considered necessary. Due to coiled tube limitations in this deep (5136 m along hole, 3700 m true vertical depth, with a maximum deviation of 89 degrees), high pressure well a hydraulic workover unit (HWU) was selected to deploy and retrieve the guns. The operation is considered a world record since this is the longest section (total gross interval of 1026 m perforated) of guns conveyed, fired underbalanced and deployed out of a live well. It is concluded that the improved productivity more than justified the additional time, effort and expenditure; considering the full life cycle of the well it is readily apparent that the operation was an economic and technical success. Details of the considerations leading to the perforating technique selection, the planning and the execution of the operation, and the validation of the technique in terms of productivity gains, are provided. 13 refs., 7 figs.

  5. Subacute right ventricle perforation by pacemaker lead presenting with left hemothorax and shock.

    Science.gov (United States)

    Nichols, Julianne; Berger, Natalie; Joseph, Praveen; Datta, Debapriya

    2015-01-01

    Cardiac perforation by pacemaker is a rare but potentially fatal complication. Acute perforations occurring within twenty-four hours of insertion of pacemaker can lead to hemopericardium, cardiac tamponade, and death. Hemothorax occurring as an acute complication of pacemaker insertion is reported but extremely rare. Previously, hemothorax and shock as a subacute complication following pacemaker insertion have not been reported. We report the case of an 85-year-old patient who presented with shock from hemothorax caused by pacemaker perforation, two weeks after insertion. Device interrogation showed normal function. Chest X-ray and echocardiogram missed lead dislocation and the diagnosis was made on computed tomogram (CT) of the chest. Following surgical repair, a new ventricular pacemaker was placed transvenously in the right ventricular septum. This case illustrates that CT scan of the chest should be performed in all patients in whom cardiac perforation by pacemaker is suspected but not diagnosed on chest X-ray and echocardiogram. Normal functioning of pacemaker on device interrogation does not exclude perforation.

  6. Toward designing semiconductor-semiconductor heterojunctions for photocatalytic applications

    Science.gov (United States)

    Zhang, Liping; Jaroniec, Mietek

    2018-02-01

    Semiconductor photocatalysts show a great potential for environmental and energy-related applications, however one of the major disadvantages is their relatively low photocatalytic performance due to the recombination of electron-hole pairs. Therefore, intensive research is being conducted toward design of heterojunctions, which have been shown to be effective for improving the charge-transfer properties and efficiency of photocatalysts. According to the type of band alignment and direction of internal electric field, heterojunctions are categorized into five different types, each of which is associated with its own charge transfer characteristics. Since the design of heterojunctions requires the knowledge of band edge positions of component semiconductors, the commonly used techniques for the assessment of band edge positions are reviewed. Among them the electronegativity-based calculation method is applied for a large number of popular visible-light-active semiconductors, including some widely investigated bismuth-containing semiconductors. On basis of the calculated band edge positions and the type of component semiconductors reported, heterojunctions composed of the selected bismuth-containing semiconductors are proposed. Finally, the most popular synthetic techniques for the fabrication of heterojunctions are briefly discussed.

  7. Percutaneous Emergency Needle Caecostomy for Prevention of Caecal Perforation

    OpenAIRE

    Limmer, Alexandra M.; Clement, Zackariah

    2017-01-01

    Caecal perforation is a life-threatening complication of large bowel obstruction with a reported mortality of 34% to 72%. This case describes the novel use of percutaneous needle caecostomy as a life-saving measure to prevent imminent caecal perforation in a 68-year-old lady with large bowel obstruction secondary to an incarcerated incisional hernia. After careful review of computed tomography images and measurement of distances from the abdominal wall to the caecum, the patient's caecum was ...

  8. Evaluation of risk factors for mortality in perforated peptic ulcer in ...

    African Journals Online (AJOL)

    Objective: To assess the risk factor that influence mortality from perforated peptic ulcer. Design: Retrospective study. Setting: Ankara Numune Teaching and Research Hospital, Ankara, Turkey. Subjects: A total of 342 patients with perforated peptic ulcer disease were identified from April 1997 to January 2004. Data for the ...

  9. Photon detectors for epithermal neutron scattering at high-ω and low-q

    International Nuclear Information System (INIS)

    Pietropaolo, A.; Senesi, R.; Tardocchi, M.; Andreani, C.; Gorini, G.

    2004-01-01

    Inelastic epithermal neutron scattering at high energy (ℎω≥1 eV) and low wave vector (q≤10 A -1 ) transfers is the unique technique for the investigation of high-energy excitations in a variety of systems, ranging from magnetic materials to semiconductors. The key issue in order to make these measurements feasible on inverse geometry spectrometers, is to develop suitable detection systems for neutrons in the energy range 1-100 eV. The Resonance Detector Spectrometer configuration has to be considered as the most promising approach for electron Volt neutron spectroscopy. This configuration will be employed in the new low angle detector bank, VLAD, planned for VESUVIO spectrometer operating at ISIS source

  10. Premixed Combustion of Kapok (ceiba pentandra seed oil on Perforated Burner

    Directory of Open Access Journals (Sweden)

    I.K.G. Wirawan

    2014-05-01

    Full Text Available Availability of fossil fuels in the world decrease gradually due to excessive fuel exploitation. This situations push researcher to look for alternative fuels as a source of renewable energy, one of them is kapok (ceiba pentandra seed oil. The aim this study was to know the behavior of laminar burning velocity, secondary Bunsen flame with open tip, cellular and triple flame. Premixed combustion of kapok seed oil was studied experimentally on perforated burner with equivalence ratio (φ varied from 0.30 until 1.07. The results showed that combustion of glycerol requires a large amount of air so that laminar burning velocity (SL is the highest at very lean mixture (φ =0.36 in the form of individual Bunsen flame on each of the perforated plate hole.  Perforated and secondary Bunsen flame both reached maximum SL similar with that of ethanol and higher than that of hexadecane. Slight increase of φ decreases drastically SL of perforated and secondary Bunsen flame. When the mixture was enriched, secondary Bunsen and perforated flame disappears, and then the flame becomes Bunsen flame with open tip and triple flame (φ = 0.62 to 1.07. Flame was getting stable until the mixture above the stoichiometry. Being isolated from ambient air, the SL of perforated flame, as well as secondary Bunsen flame, becomes equal with non-isolated flame. This shows the decreasing trend of laminar burning velocity while φ is increasing. When the mixture was enriched island (φ = 0.44 to 0.48 and petal (φ = 0.53 to 0.62 cellular flame take place. Flame becomes more unstable when the mixture was changed toward stoichiometry.

  11. The ectopic appendicolith from perforated appendicitis as a cause of tubo-ovarian abscess

    International Nuclear Information System (INIS)

    Vyas, Rajashree C.; Sides, Corey; Klein, Deborah J.; Reddy, Sireesha Y.; Santos, Mary C.

    2008-01-01

    Acute appendicitis is a common surgical cause of abdominal pain in the pediatric population. History and physical examination are atypical in up to a third of patients. Known potential complications of untreated or delayed management of acute appendicitis include appendiceal perforation, periappendiceal abscess formation, peritonitis, bowel obstruction and rarely septic thrombosis of mesenteric vessels. We report an unusual complication of perforated appendicitis. A tubo-ovarian abscess developed secondary to appendicolith migration into the right fallopian tube in a patient who had undergone interval laparoscopic appendectomy for perforated appendicitis. The retained appendicolith was visualized within the obstructed and dilated fallopian tube on contrast-enhanced CT. We discuss the CT imaging features of this unusual complication of perforated appendicitis. (orig.)

  12. The ectopic appendicolith from perforated appendicitis as a cause of tubo-ovarian abscess

    Energy Technology Data Exchange (ETDEWEB)

    Vyas, Rajashree C.; Sides, Corey; Klein, Deborah J. [University of Rochester Medical Center, Rochester, NY (United States); Reddy, Sireesha Y. [University of Rochester, Obstetrics and Gynecology, Rochester, NY (United States); Santos, Mary C. [University of Rochester, Pediatric Surgery, Rochester, NY (United States)

    2008-09-15

    Acute appendicitis is a common surgical cause of abdominal pain in the pediatric population. History and physical examination are atypical in up to a third of patients. Known potential complications of untreated or delayed management of acute appendicitis include appendiceal perforation, periappendiceal abscess formation, peritonitis, bowel obstruction and rarely septic thrombosis of mesenteric vessels. We report an unusual complication of perforated appendicitis. A tubo-ovarian abscess developed secondary to appendicolith migration into the right fallopian tube in a patient who had undergone interval laparoscopic appendectomy for perforated appendicitis. The retained appendicolith was visualized within the obstructed and dilated fallopian tube on contrast-enhanced CT. We discuss the CT imaging features of this unusual complication of perforated appendicitis. (orig.)

  13. Intestinal volvulus and perforation caused by multiple magnet ingestion: report of a case.

    Science.gov (United States)

    Ilçe, Zekeriya; Samsum, Hakan; Mammadov, Emil; Celayir, Sinan

    2007-01-01

    Ingested magnets can cause intestinal fistulas, perforation, and obstruction. There have been reports of magnet ingestion causing intestinal volvulus, but multiple magnet ingestion causing perforation and intestinal volvulus in a child is very unusual. We report the case of a 4-year-old girl, who ingested four magnets she acquired as toys, which caused intestinal volvulus and perforation as a result of pressure necrosis, several days after ingestion. At surgery we repaired two perforations, but additional bowel resection was not required. The patient was discharged on postoperative day 10. If multiple magnet ingestion is suspected in a child, the child must be monitored carefully. If there are signs of obstruction, emergency surgery is mandatory.

  14. Conservative treatment of perforated upper gastrointestinal tract

    International Nuclear Information System (INIS)

    Naoi, Daishi; Sano, Wataru; Nakata, Yasuyuki; Yano, Kentaro; Suzuki, Takeshi; Chiku, Tsuyoshi; Tashiro, Tsuguhiko

    2009-01-01

    In order to clarify the validity of indication criteria of the conservative treatment for perforated upper gastrointestinal tract, a retrospective study was carried out. We enrolled 28 patients with perforation of the gastrointestinal tract who were determined to receive conservative treatment at the time of hospitalization from January 2000 to December 2007. When the following criteria were satisfied, we treated the patients by the conservative treatment after informed consent was gained from them and their families: stable condition of vital signs; peritoneal signs localized in the upper abdomen; and no or slight fluid collection at the Douglas' pouch determined by computed tomography. Patients who showed changes for the worse of peritonitis or increased fluid collection during follow-up were promptly converted to surgery. Six patients were converted to surgery, but all of them were discharged very much improved. We compared patient's data of the conservative treatment group and the converted surgery group at the time of consultation. All data were not statistically different between two groups. If all criteria are satisfied, it seemed that we can start conservative treatment for perforated gastrointestinal tract with careful observation and the system of prompt conversion to operation for patients who showed changes for the worse of peritonitis or increased fluid collection. (author)

  15. Colorectal cancer complicated by perforation. Specific features of surgical tactics

    Directory of Open Access Journals (Sweden)

    S. N. Shchaeva

    2015-01-01

    Full Text Available Objective: to assess the immediate results of surgical interventions for colorectal cancer complicated by perforation.Materials and methods. The immediate results of surgical treatment were retrospectively analyzed in 56 patients with colorectal cancer complicated by perforated colon cancer, who had been treated at Smolensk surgical hospitals in 2001 to 2013. Patients with diastatic perforation of the colon in the presence of decompensated obturation intestinal obstruction of tumor genesis were not included into this investigation.Results. The immediate results of uni- and multistage surgical interventions were analyzed in relation to the extent of peritonitis and the stage of colon cancer. More satisfactory immediate results were observed after multistage surgical treatment. Following these interventions, a fatal outcome of disseminated peritonitis in the presence of performed colorectal cancer was recorded in 8 (53.3 % cases whereas after symptomatic surgery there were 11 (67.8 % deaths. A fatal outcome was noted in 1 case (7.7 % after multistage surgery.Discussion. The results of surgical treatment in the patients with perforated colorectal cancer are directly related to the degree of peritonitis and the choice of surgical tactics.

  16. COMPARATIVE ANALYSIS OF PRIMARY REPAIR VERSUS RESECTION AND ANASTOMOSIS IN JEJUNOILEAL PERFORATIONS IN SOUTHERN ODISHA

    Directory of Open Access Journals (Sweden)

    Charan Panda

    2017-11-01

    Full Text Available BACKGROUND Small intestinal perforation remains a major issue in this region of study. Most often, it is caused by either infections due to typhoid, tuberculosis or traumatic due to blunt or penetrating injuries. The mortality reported is related to various factors including age, delayed treatment, sepsis at presentation and inadequate treatment due to lack of resources. Management is therefore complex not only with regards to choose the most suitable surgical treatment, but also as regards an early diagnosis of complications, which is difficult in absence of diagnostic modalities that are often not available. The aim of the study is to compare primary repair versus intestinal resection and anastomosis in case of jejunoileal perforations due to various aetiologies. MATERIALS AND METHODS 60 patients with acute peritonitis underwent emergency laparotomy. Aetiology, number of perforations, size of perforations, site of perforations, surgical procedure undertaken and postoperative complications were recorded. The patients were divided into two groups according to the surgical procedure adapted at laparotomy; primary repair and intestinal resection and anastomosis. Clinical data, intraoperative findings and complications were evaluated and compared. RESULTS 40 out of 60, we found jejunoileal perforations, gastroduodenal in 20 patients. 23 had undergone primary repair and 17 resection and anastomosis. Postoperative complications were compared among both groups in relation to various factors. Conclusion was drawn as to prefer, which surgery in which group of patients. CONCLUSION In our study, detailed analysis of the complication pattern shows primary closure is associated with less number of complications in traumatic cases and resection and anastomosis is associated with lesser complications in infective cases. Primary closure is less complicated for single perforations as compared to multiple perforations. Resection and anastomosis is less

  17. ATLAS silicon microstrip Semiconductor Tracker (SCT)

    International Nuclear Information System (INIS)

    Unno, Y.

    2000-01-01

    Silicon microstrip semiconductor tracking system (SCT) will be in operation in the ATLAS detector in the Large Hadron Collider (LHC) at CERN. Challenging issues in the SCT are the radiation tolerance to the fluence of 2x10 14 1-MeV-neutron-equivalent particles/cm 2 at the designed luminosity of 1x10 34 cm -2 /s of the proton-proton collisions and the speed of the electronics to identify the crossing bunches at 25 ns. The developments and the status of the SCT are presented from the point of view of these issues. Series production of the SCT will start in the year 2001 and the SCT will be installed into the ATLAS detector during 2003-2004

  18. Iatrogenic stomach perforation complicating unrecognized ...

    African Journals Online (AJOL)

    We report a case of 21-year-old male patient with traumatic diaphragmatic herniation of the stomach that is misdiagnosed as a hemo-pneumothorax with the resulting insertion of a chest tube causing iatrogenic perforation of the stomach and draining of gastric content into the pleural cavity. An emergency thoracotomy was ...

  19. Augmented reality and dynamic infrared thermography for perforator mapping in the anterolateral thigh.

    Science.gov (United States)

    Cifuentes, Ignacio Javier; Dagnino, Bruno Leonardo; Salisbury, María Carolina; Perez, María Eliana; Ortega, Claudia; Maldonado, Daniela

    2018-05-01

    Dynamic infrared thermography (DIRT) has been used for the preoperative mapping of cutaneous perforators. This technique has shown a positive correlation with intraoperative findings. Our aim was to evaluate the accuracy of perforator mapping with DIRT and augmented reality using a portable projector. For this purpose, three volunteers had both of their anterolateral thighs assessed for the presence and location of cutaneous perforators using DIRT. The obtained image of these "hotspots" was projected back onto the thigh and the presence of Doppler signals within a 10-cm diameter from the midpoint between the lateral patella and the anterior superior iliac spine was assessed using a handheld Doppler device. Hotspots were identified in all six anterolateral thighs and were successfully projected onto the skin. The median number of perforators identified within the area of interest was 5 (range, 3-8) and the median time needed to identify them was 3.5 minutes (range, 3.3-4.0 minutes). Every hotspot was correlated to a Doppler sound signal. In conclusion, augmented reality can be a reliable method for transferring the location of perforators identified by DIRT onto the thigh, facilitating its assessment and yielding a reliable map of potential perforators for flap raising.

  20. Increased Flap Weight and Decreased Perforator Number Predict Fat Necrosis in DIEP Breast Reconstruction

    Directory of Open Access Journals (Sweden)

    Carolyn L. Mulvey, BS

    2013-05-01

    Conclusions: Flaps with increasing weight have increased risk of fat necrosis. These data suggest that inclusion of more than 1 perforator may decrease odds of fat necrosis in large flaps. Perforator flap breast reconstruction can be performed safely; however, considerations concerning race, body mass index, staging with tissue expanders, perforator number, and flap weight may optimize outcomes.

  1. A shovel with a perforated blade reduces energy expenditure required for digging wet clay.

    Science.gov (United States)

    Harivanam, Sridhar; Marklin, Richard W; Papanek, Paula E; Cariapa, Vikram

    2010-08-01

    A shovel with a blade perforated with small holes was tested to see whether a worker would use less whole-body energy to dig wet clay than with a shovel with an opaque blade. A perforated shovel is hypothesized to require less whole-body energy on the basis of adhesion theory; a smaller surface area would require less physical effort to dig and release soil from the blade. The study involved 13 workers from an electric utility who dug wet clay with two 1.5-m long-handled point shovels, which differed only in blade design (perforated and opaque). Oxygen consumption was measured with a portable system while each worker dug wet clay at a self-regulated pace for 10 min. There was no significant difference in number of scoops dug during the 10-min sessions, but workers dug 9.5% more weight of clay with the perforated shovel than with the conventional shovel (404 kg vs. 369 kg, respectively). Furthermore, stable oxygen uptake normalized to weight of participant and to the weight of clay dug revealed that participants expended 11.7% less relative energy per kilogram of clay dug with the perforated shovel. A point shovel with a perforated blade is recommended for digging and shoveling wet clay. However, the extra weight that workers chose to dig with the perforated shovel may increase the loading on the spine and may offset the metabolic advantages. Manual shoveling is a common task, and workers may experience less whole-body and muscle fatigue when using a perforated shovel.

  2. Colorectal cancer with intestinal perforation – a retrospective analysis of treatment outcomes

    Science.gov (United States)

    Woda, Łukasz; Tojek, Krzysztof; Jarmocik, Paweł; Jawień, Arkadiusz

    2014-01-01

    Aim of the study Colorectal cancer (CRC) is one of the leading cause of death in European population. It progresses without any symptoms in the early stages or those clinical symptoms are very discrete. The aim of this study was a retrospective analysis of treatment outcomes in patients with colorectal cancer complicated with intestinal perforation. Material and methods A retrospective analysis of patients urgently operated upon in our Division of General Surgery, because of large intestine perforation, from February 1993 to February 2013 has been made. Results were compared with a group of patients undergoing the elective surgery for colorectal cancer in the same time and Division. Results Intestinal perforation occurred more often in males (6.52% vs. 6.03%), patients with mucous component in histopathological examination (9.09% vs. 6.01%) and with clinicaly advanced CRC. Patients treated because of perforation had a five-fold higher 30 day mortality rate (9.09% vs. 1.83%), however long-term survival did not differ significantly in both groups. After resectional surgery in 874 patients an intestinal anastomosis was made. Anastomotic leakage was present in 23 (2.6%) patients. This complication occurred six-fold more frequently in a group of patients operated upon because of intestinal perforation (12.20% vs. 2.16%). Conclusions In patients with CRC complicated with perforation of the colon in a 30-day observation significantly higher rate of complications and mortality was shown, whereas there was no difference in distant survival rates. PMID:25784840

  3. Neutron absorbed dose in a pacemaker CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Borja H, C. G.; Guzman G, K. A.; Valero L, C. Y.; Banuelos F, A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Paredes G, L., E-mail: candy_borja@hotmail.com [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-11-15

    The absorbed dose due to neutrons by a Complementary Metal Oxide Semiconductor (CMOS) has been estimated using Monte Carlo methods. Eventually a person with a pacemaker becomes a patient that must be treated by radiotherapy with a linear accelerator; the pacemaker has integrated circuits as CMOS that are sensitive to intense and pulsed radiation fields. When the Linac is working in Bremsstrahlung mode an undesirable neutron field is produced due to photoneutron reactions; these neutrons could damage the CMOS putting the patient at risk during the radiotherapy treatment. In order to estimate the neutron dose in the CMOS a Monte Carlo calculation was carried out where a full radiotherapy vault room was modeled with a W-made spherical shell in whose center was located the source term of photoneutrons produced by a Linac head operating in Bremsstrahlung mode at 18 MV. In the calculations a phantom made of tissue equivalent was modeled while a beam of photoneutrons was applied on the phantom prostatic region using a field of 10 x 10 cm{sup 2}. During simulation neutrons were isotropically transported from the Linac head to the phantom chest, here a 1 {theta} x 1 cm{sup 2} cylinder made of polystyrene was modeled as the CMOS, where the neutron spectrum and the absorbed dose were estimated. Main damages to CMOS are by protons produced during neutron collisions protective cover made of H-rich materials, here the neutron spectrum that reach the CMOS was calculated showing a small peak around 0.1 MeV and a larger peak in the thermal region, both connected through epithermal neutrons. (Author)

  4. A theoretical model describing arterial flow in the DIEP flap related to number and size of perforator vessels.

    Science.gov (United States)

    Patel, Sameer A; Keller, Alex

    2008-11-01

    The deep inferior epigastric perforator flap is rapidly becoming a more widely employed method of autologous breast reconstruction. The technical considerations involved in the execution of the flap are many and include the selection of perforators to be incorporated in the flap. We attempt to give a mathematical explanation, based on the physics of flow through vessels and the properties of circuits with multiple resistances in parallel, for the clinical observations which have been arrived at through clinical experience. We compare the system of perforators to a circuit with multiple resistances in parallel. Each of these resistances represents a perforator vessel. In the event that there is only one perforator vessel, this simplifies to a single resistance in series with the capillary bed perfusing the flap. The flow through the flap is optimized by incorporation of the largest diameter perforator. Inclusion of other smaller perforators in addition to the largest diameter perforator will reduce the overall resistance, but this reduction in resistance is dependent on the diameter of the additional perforator and may not be worth the additional trauma of dissection and increased operative time. Incorporating several smaller perforators at the expense of excluding the largest diameter perforator appears to increase the overall resistance, unless the smaller perforators are only slightly smaller. We conclude that the best perfused flap involves use of the largest diameter vessel, that although adding additional perforators will decrease the resistance and increase flow, the magnitude of the benefit depends largely on the calibre of the additional perforator, and that this benefit needs to be weighed against the downside of increased muscle and facial trauma.

  5. Perforation of dental gloves during prosthodontic treatments as assessed by the conductivity and water inflation tests.

    Science.gov (United States)

    Nikawa, H; Hamada, T; Tamamoto, M; Abekura, H; Murata, H

    1996-01-01

    The incidence of latex glove perforation during prosthodontic treatment was investigated on 122 occasions using two methods, a conductivity test and a water inflation test. Latex glove perforation was detected in 38.5% of the treatments by the conductivity test and in 27.9% by the water inflation test. The perforation went unrecognized in 74.7% of the occurrences (35/47 incidents) using the conductivity test and in 64.7% (22/34) when the water inflation test was used. Of the total 55 glove perforations, 21 perforations were detected only by conductivity test, 3 were detected only by the water inflation test, and 31 perforations were detected by both methods, which suggested that the conductivity test is more sensitive than the water inflation test for the detection of glove perforation. The results of this research suggested that even when latex gloves are worn, the risk to prosthodontists of exposure to body fluids remains in four of every six treatments, often without the awareness of the prosthodontist.

  6. Neonatal gastric perforation: a report of 3 cases and literature review ...

    African Journals Online (AJOL)

    Neonatal gastric perforation (NGP) is an uncommon disease. Historical reports regard the aetiology as spontaneous while the mortality remains high. We present the report of the cases of neonatal gastric perforations who presented to our facility, its diverse aetiology and a review of the literature. Their clinical data including ...

  7. Persistent perforation in non-faeculant diverticular peritonitis--incidence and clinical significance.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2013-02-01

    Non-resectional strategies (NRS) have improved outcomes for a sub-group of patients with perforated diverticulitis. NRS are applicable to patients with non-faeculant peritonitis (Hinchey II and III). Success is dependent on the initial perforation sealing, which Hinchey estimated occurred \\'most of the time\\'. An exact percentage remains ill-defined.

  8. Micro direct methanol fuel cell with perforated silicon-plate integrated ionomer membrane

    DEFF Research Database (Denmark)

    Larsen, Jackie Vincent; Dalslet, Bjarke Thomas; Johansson, Anne-Charlotte Elisabeth Birgitta

    2014-01-01

    This article describes the fabrication and characterization of a silicon based micro direct methanol fuel cell using a Nafion ionomer membrane integrated into a perforated silicon plate. The focus of this work is to provide a platform for micro- and nanostructuring of a combined current collector...... at a perforation ratio of 40.3%. The presented fuel cells also show a high volumetric peak power density of 2 mW cm−3 in light of the small system volume of 480 μL, while being fully self contained and passively feed....... and catalytic electrode. AC impedance spectroscopy is utilized alongside IV characterization to determine the influence of the plate perforation geometries on the cell performance. It is found that higher ratios of perforation increases peak power density, with the highest achieved being 2.5 mW cm−2...

  9. Comparison of differently viscous iodinated and bariumcontaining contrast agents in the detection of pharyngeal perforation

    International Nuclear Information System (INIS)

    Keberle, M.; Wittenberg, G.; Trusen, A.; Hahn, D.; Baumgartner, W.

    2001-01-01

    Purpose: In contrast to esophageal perforations, the more radiopaque barium-suspensions are not as important as iodinated aqueous contrast agents for the detection of pharyngeal perforations. This study was performed to find out whether the highly different viscosities (of iodinated and barium-containing contrast agents with comparable radiopacities) are a reason for this. Methods: Viscosity, subjective difference in contrast, and CT-density of an iodinated aqueous (Telebrix) and a 50 wt/vol% barium-containing contrast agent (Micropaque) were determined. Moreover, to exclude postoperative perforation, 104 patients were prospectively examined by pharyngography using both contrast media. Pharyngographies of patients with perforation were later compared by two independent readers. All patients with perforation were followed up clinically to exclude complications due to barium administration. Results: In-vitro comparison showed comparable radiopacity but the 50 wt/vol% barium-suspension was much more viscous that the iodinated contrast agent. During pharyngography, totally, 14 perforations were clearly delineated with the iodinated aqueous contrast agent. However, two of them were not detected with the barium-suspension. All the other perforations presented equally. Conclusions: Given a sufficient radiopacity, a low viscosity appears to be essential for a contrast agent to detect especially pharyngeal perforations. Thus, we recommend the sole use of an iodinated contrast agent (at suspicion of aspiration as isoosmolar variant) for this purpose. (orig.) [de

  10. Directional bending wave propagation in periodically perforated plates

    DEFF Research Database (Denmark)

    Andreassen, Erik; Manktelow, Kevin; Ruzzene, Massimo

    2015-01-01

    We report on the investigation of wave propagation in a periodically perforated plate. A unit cell with double-C perforations is selected as a test article suitable to investigate two-dimensional dispersion characteristics, group velocities, and internal resonances. A numerical model, formulated...... using Mindlin plate elements, is developed to predict relevant wave characteristics such as dispersion, and group velocity variation as a function of frequency and direction of propagation. Experimental tests are conducted through a scanning laser vibrometer, which provides full wave field information...... for the design of phononic waveguides with directional and internal resonant characteristics....

  11. Perforated ileal duplication cyst with haemorrhagic pseudocyst formation

    International Nuclear Information System (INIS)

    Hwang, Im Kyung; Kim, Bong Soo; Kim, Heung Chul; Lee, In Sun; Hwang, Woo Chul; Namkung, Sook

    2003-01-01

    Duplication cysts of the gastrointestinal tract are rare congenital abnormalities. Ectopic gastric mucosa, which can be found in duplications, may cause peptic ulceration, gastrointestinal bleeding or perforation. We report a 1-year-old boy with a perforated ileal duplication cyst with haemorrhagic pseudocyst formation caused by peptic ulceration of the duplication cyst. It presented a snowman-like appearance consisting of a small, thick-walled, true enteric cyst and a large, thin-walled haemorrhagic pseudocyst on US and CT. It is an unusual manifestation of a duplication cyst, which has not been reported in the English language literature. (orig.)

  12. Non-invasive vascular imaging in perforator flap surgery

    International Nuclear Information System (INIS)

    Saba, Luca; Piga, Mario; Atzeni, Matteo; Ribuffo, Diego; Rozen, Warren Matthew; Alonso-Burgos, Alberto; Bura, Raffaella

    2013-01-01

    Preoperative imaging using a range of imaging modalities has become increasingly popular for preoperative planning in plastic surgery, in particular in perforator flap surgery. Modalities in this role include ultrasound (US), magnetic resonance angiography (MRA), and computed tomographic angiography (CTA). The evidence for the use of these techniques has been reported in only a handful of studies. In this paper we conducted a non-systematic review of the literature to establish the role for each of these modalities. The role of state-of-the-art vascular imaging as an application in perforator flap surgery is thus offered

  13. Pneumatosis cystoides intestinalis associated with massive free air mimicking perforated diffuse peritonitis.

    Science.gov (United States)

    Sakurai, Yoichi; Hikichi, Masahiro; Isogaki, Jun; Furuta, Shinpei; Sunagawa, Risaburo; Inaba, Kazuki; Komori, Yoshiyuki; Uyama, Ichiro

    2008-11-21

    While pneumatosis cystoides intestinalis (PCI) is a rare disease entity associated with a wide variety of gastrointestinal and non-gastrointestinal disorders, PCI associated with massive intra- and retroperitoneal free air is extremely uncommon, and is difficult to diagnose differentially from perforated peritonitis. We present two cases of PCI associated with massive peritoneal free air and/or retroperitoneal air that mimicked perforated peritonitis. These cases highlight the clinical importance of PCI that mimics perforated peritonitis, which requires emergency surgery. Preoperative imaging modalities and diagnostic laparoscopy are useful to make an accurate diagnosis.

  14. Modeling of displacement damage in silicon carbide detectors resulting from neutron irradiation

    Science.gov (United States)

    Khorsandi, Behrooz

    There is considerable interest in developing a power monitor system for Generation IV reactors (for instance GT-MHR). A new type of semiconductor radiation detector is under development based on silicon carbide (SiC) technology for these reactors. SiC has been selected as the semiconductor material due to its superior thermal-electrical-neutronic properties. Compared to Si, SiC is a radiation hard material; however, like Si, the properties of SiC are changed by irradiation by a large fluence of energetic neutrons, as a consequence of displacement damage, and that irradiation decreases the life-time of detectors. Predictions of displacement damage and the concomitant radiation effects are important for deciding where the SiC detectors should be placed. The purpose of this dissertation is to develop computer simulation methods to estimate the number of various defects created in SiC detectors, because of neutron irradiation, and predict at what positions of a reactor, SiC detectors could monitor the neutron flux with high reliability. The simulation modeling includes several well-known---and commercial---codes (MCNP5, TRIM, MARLOWE and VASP), and two kinetic Monte Carlo codes written by the author (MCASIC and DCRSIC). My dissertation will highlight the displacement damage that may happen in SiC detectors located in available positions in the OSURR, GT-MHR and IRIS. As extra modeling output data, the count rates of SiC for the specified locations are calculated. A conclusion of this thesis is SiC detectors that are placed in the thermal neutron region of a graphite moderator-reflector reactor have a chance to survive at least one reactor refueling cycle, while their count rates are acceptably high.

  15. Mucosal Perforation During Laparoscopic Heller Myotomy Has No Influence on Final Treatment Outcome.

    Science.gov (United States)

    Salvador, Renato; Spadotto, Lorenzo; Capovilla, Giovanni; Voltarel, Guerrino; Pesenti, Elisa; Longo, Cristina; Cavallin, Francesco; Nicoletti, Loredana; Ruol, Alberto; Valmasoni, Michele; Merigliano, Stefano; Costantini, Mario

    2016-12-01

    The aims of the study were (a) to examine the final outcome in patients experiencing accidental mucosal perforation during laparoscopic Heller myotomy with Dor fundoplication (LHD) and (b) to evaluate whether perforation episodes might influence the way in which surgeons subsequently approached the LHD procedure. We studied all consecutive patients that underwent LHD between 1992 and 2015. Patients were divided into two main groups: those who experienced an intraoperative mucosal perforation (group P) and those whose LHD was uneventful (group NP). Two additional groups were compared: group A, which consisted of patients operated by a given surgeon immediately before a perforation episode occurred, and group B, which included those operated immediately afterwards. Eight hundred seventy-five patients underwent LHD; a mucosal perforation was detected in 25 patients (2.9 %), which was found unrelated to patients' symptom's score and age, radiological stage, manometric pattern, or the surgeon's experience. The median postoperative symptom score was similar for the two groups as the failure rate: 92 failures in group NP (10.8 %) and 4 in group P (16 %) (p = 0.34); moreover, symptoms recurred in 2 patients of group A (10 %) and 3 patients of group B (15 %) (p = 0.9). Accidental perforation during LHD is infrequent and impossible to predict on the grounds of preoperative therapy or the surgeon's personal experience. Despite a longer surgical procedure and hospital stay, the outcome of LHD is much the same as for patients undergoing uneventful myotomy. A recent mucosal perforation does not influence the surgeon's subsequent performance.

  16. Traumatic tympanic membrane perforations: characteristics and ...

    African Journals Online (AJOL)

    Objective: To characterize traumatic tympanic membrane perforation (TTMP) in terms of distribution, mechanisms, and outcome of treatment. To assess the factors influencing such outcome. Study design: Prospective analytical study, assessing outcomes post-injuries. Setting: Clinical department of a tertiary referral hospital.

  17. Conservative Management of an Epicardial Collateral Perforation During Retrograde Chronic Total Occlusion Percutaneous Coronary Intervention.

    Science.gov (United States)

    Ngo, Christian; Christopoulos, George; Brilakis, Emmanouil S

    2016-01-01

    Coronary artery perforation is a highly feared complication of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) and can lead to pericardial effusion, tamponade, and, rarely, emergent cardiac surgery. Perforation of epicardial collaterals during retrograde CTO-PCI may be particularly challenging to treat, as embolization from both sides of the perforation may be required to control the bleeding. However, conservative measures can occasionally be effective. We present a case of epicardial collateral vessel perforation that was managed conservatively with anticoagulation reversal.

  18. Delayed Diagnosis of Iatrogenic Bladder Perforation in a Neonate

    Directory of Open Access Journals (Sweden)

    Antoinette S. Birs

    2016-01-01

    Full Text Available Iatrogenic bladder injuries have been reported in the neonate during umbilical artery/vein catheterization, voiding cystourethrogram, urinary catheterizations, and overwhelming hypoxic conditions. Patients with iatrogenic bladder perforations can present with acute abdomen indicating urinary peritonitis, septic-uremic shock, or subtle symptoms like abdominal distension, pain, hematuria, uremia, electrolyte imbalances, and/or difficulty urinating. The following neonatal case report of perforated bladder includes a review of the signs, symptoms, diagnostic tools, and management of bladder injury in neonates.

  19. A CLINICAL STUDY TO ANALYSE THE SPECTRUM OF PERITONITIS DUE TO HOLLOW VISCUS PERFORATION

    Directory of Open Access Journals (Sweden)

    Sai Datta

    2015-07-01

    Full Text Available Perforation peritonitis is the one of the common abdominal surgical emergency . The spectrum of etiology of perforation in Tropical countries continues to be different from its Western counterpart. The objective of the study was to highlight the spectrum of perforation peritonitis as encountered at K aturi M edical C ollege and H ospital , G untur. A.P. Hundred consec utive cases of perforation peritonitis over a period of 26 months . (June 2010 - July 2012 were reviewed in terms of clinical presentation, operative findings and postoperative course retrospectively. The most common type of perforation in our series was per forated duodenal ulcer (56 cases followed by Appendicular (16 cases, Ileal (12 cases, Colonic ( 6 cases, Gastric ( 4 cases, Jejunal (2 cases, Gall bladder (2 cases, Anastomotic ulcer ( 2 cases were reported . Despite delay in seeking medical treatment (32%, the overall mortality (11% , favorably comparable with other published series though the overall morbidity (29% was favorable. In contrast to western literature, where lower gastrointestinal tract perforations predominate, upper gastrointestinal tr act perforations constitute the majority of cases in India. Mostly males and elderly people are affected due to injudicious usage of NSAIDS, alcohol, smoking. ( 11 Withdrawal from these habits and using of proton pump inhibitors and H - Pylori eradication which warrant early recognition and prompt treatment to avoid serious complications and death.

  20. Investigation of incidence and risk factors for surgical glove perforation in small animal surgery.

    Science.gov (United States)

    Hayes, Galina M; Reynolds, Deborah; Moens, Noel M M; Singh, Ameet; Oblak, Michelle; Gibson, Thomas W G; Brisson, Brigitte A; Nazarali, Alim; Dewey, Cate

    2014-05-01

    To identify incidence and risk factors for surgical glove perforation in small animal surgery. Observational cohort study. Surgical gloves (n = 2132) worn in 363 surgical procedures. All gloves worn by operative personnel were assessed for perforation at end-procedure using a water leak test. Putative risk factors were recorded by a surgical team member. Associations between risk factors and perforation were assessed using multivariable multi-level random-effects logistic regression models to control for hierarchical data structure. At least 1 glove perforation occurred in 26.2% of procedures. Identified risk factors for glove perforation included increased surgical duration (surgery >1 hour OR = 1.79, 95% CI = 1.12-2.86), performing orthopedic procedures (OR = 1.88; 95% CI = 1.23-2.88), any procedure using powered instruments (OR = 1.93; 95% CI = 1.21-3.09) or surgical wire (OR = 3.02; 95% CI = 1.50-6.05), use of polyisoprene as a glove material (OR = 1.59, 95% CI = 1.05-2.39), and operative role as primary surgeon (OR = 2.01; 95% CI = 1.35-2.98). The ability of the wearer to detect perforations intraoperatively was poor, with a sensitivity of 30.8%. There is a high incidence of unrecognized glove perforations in small animal surgery. © Copyright 2014 by The American College of Veterinary Surgeons.

  1. Risk factors in patients surgically treated for peptic ulcer perforation

    DEFF Research Database (Denmark)

    Møller, Morten Hylander; Shah, Kamran; Bendix, Jørgen

    2009-01-01

    OBJECTIVE: The overall mortality for patients undergoing surgery for perforated peptic ulcer has increased despite improvements in perioperative monitoring and treatment. The objective of this study was to identify and describe perioperative risk factors in order to identify ways of optimizing...... the treatment and to improve the outcome of patients with perforated peptic ulcer. MATERIAL AND METHODS: Three hundred and ninety-eight patients undergoing emergency surgery in four university hospitals in Denmark were included in the study. Information regarding the pre-, intra- and postoperative phases were...... insufficiency upon admission and insufficient postoperative nutrition have been added to the list of independent risk factors for death within 30 days of surgery in patients with peptic ulcer perforation. Finding that shock upon admission, reduced albumin blood levels upon admission, renal insufficiency upon...

  2. Clinical features and outcomes of delayed perforation after endoscopic submucosal dissection for early gastric cancer.

    Science.gov (United States)

    Hanaoka, N; Uedo, N; Ishihara, R; Higashino, K; Takeuchi, Y; Inoue, T; Chatani, R; Hanafusa, M; Tsujii, Y; Kanzaki, H; Kawada, N; Iishi, H; Tatsuta, M; Tomita, Y; Miyashiro, I; Yano, M

    2010-12-01

    Perforation is a major complication of endoscopic submucosal dissection (ESD) for early gastric cancer (EGC). However, there have been no reports on delayed perforation after ESD for EGC. We aimed to elucidate the incidence and outcomes of delayed perforation after ESD. Clinical courses in 1159 consecutive patients with 1329 EGCs who underwent ESD were investigated. Delayed perforation occurred in six patients (0.45 %). All these patients had complete en bloc resection without intraoperative perforation during ESD. Five of six perforations were located in the upper third of the stomach, while one lesion was found in the middle third. Symptoms of peritoneal irritation with rebound tenderness presented within 24 h after ESD in all cases. One patient did not require surgery because the symptoms were localized, and recovered with conservative antibiotic therapy by nasogastric tube placement. The remaining five patients required emergency surgery. There was no mortality in this case series. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Spontaneous acalculous gallbladder perforation in a man secondary to chemotherapy and radiation: A rare case report.

    Science.gov (United States)

    Zhang, Jungang; Shen, Guoliang; Shi, Ying; Zhang, Chengwu; Hong, Defei; Jin, Li; Yang, Hongguo; Sun, Wei; Cai, Hanhui; Hu, Zhiming; Wu, Weiding

    2018-05-01

    Gallbladder perforation is a serious clinical condition and associated with high morbidity and mortality. A definitive diagnosis is contentious before surgery. We herein report a case of perforation of the gallbladder neck secondary to chemotherapy and radiation for nasopharyngeal carcinoma patient. Gallbladder perforation secondary to chemotherapy and radiation. To decrease the mortality associated with gallbladder perforation, Laparoscopic cholecystectomy and peritoneal lavage were performed followed for gallbladder perforation patient because of chemotherapy and radiation. The patient recovered fully without serious complication and discharged on the 10th postoperative day. A pathological examination of the resected gallbladder revealed cholecystitis in the thinning of the neck. Early diagnosis and surgical intervention of gallbladder perforation in relation to asopharyngeal carcinoma chemotherapy and radiation are of prime importance. The laparoscopic procedure is safe and feasible in the selected patients.

  4. Computational analysis of acoustic transmission through periodically perforated interfaces

    Directory of Open Access Journals (Sweden)

    Rohan E.

    2009-06-01

    Full Text Available The objective of the paper is to demonstrate the homogenization approach applied to modelling the acoustic transmission on perforated interfaces embedded in the acoustic fluid. We assume a layer, with periodically perforated obstacles, separating two half-spaces filled with the fluid. The homogenization method provides limit transmission conditions which can be prescribed at the homogenized surface representing the "limit" interface. The conditions describe relationship between jump of the acoustic pressures and the transversal acoustic velocity, on introducing the "in-layer pressure" which describes wave propagation in the tangent directions with respect to the interface.This approach may serve as a relevant tool for optimal design of devices aimed at attenuation of the acoustic waves, such as the engine exhaust mufflers or other structures fitted with sieves and grillages. We present numerical examples of wave propagation in a muffler-like structure illustrating viability of the approach when complex 3D geometries of the interface perforation are considered.

  5. Irradiation damages of semiconductor devices and their improvement

    Energy Technology Data Exchange (ETDEWEB)

    Uwatoko, Yoshiya [Saitama Univ., Urawa (Japan); Ohyama, Hidenori; Hayama, Kiyoteru; Hakata, Tetsuya; Kudou, Tomohiro

    1998-01-01

    In this study, effect of radiation on semiconductor devices was evaluated at both sides of electrical and crystalline properties for two years from 1995 fiscal years. And, damage of Si(sub 1-x)Ge(sub x) device was considered at viewpoints of Ge content and sprung-out atomic number and non ionization energy loss of constituting atom formed by radiation on its radiation source dependency of damage. This paper was a report on proton beam damage of the Si(sub 1-x)Ge(sub x) device, neutron damage of InGaAs photodiode, and effect of Ga content and kinds of beam on their damages. (G.K.)

  6. A case of radiation enteritis with perforated peritonitis caused by a piece of eggshell

    International Nuclear Information System (INIS)

    Kitamura, Hirotaka; Maeda, Kazuya; Miyanaga, Tamonn; Doden, Kenji; Hattori, Masakazu; Hashizume, Yasuo

    2011-01-01

    The patient was a woman in her sixties who had received radiation therapy for cancer of uterine cervix 7 years earlier and had been suffering from diarrhea for these several years. The patient was seen at our emergency clinic because of a 5 hour-history of lower abdominal pain at the beginning of July 2010. An abdominal CT scan showed free air and ascites. A high density structure 1.5 cm in size was identified within the small intestine, but its relation with the perforation was obscure. Emergency operation was done with the most likely diagnosis of intestinal perforation and general peritonitis. When the lower abdomen was opened by midline incision, about 200 ml of cloudy ascites was observed and the ileum became white in color and hard resulting from the radiation therapy. A perforation was identified in the ileum about 15 cm distant from the ileocecal valve, and a 1.5-cm sized thin and hard material was palpated within the intestine at the same portion. Ilececal resection including the perforated portion was performed and functional end-to-end anastomosis was made at a grossly normal area. There was a piece of eggshell 1.5-cm in size in the perforated portion in the resected specimen. From this together with histopathologial findings, perforation of the small intestine caused by a piece of eggshell associated with radiation enteritis was finally diagnosed. Small bowel perforation must be kept in mind as a possible late complication of radiation therapy, however, no cases of small bowel perforation caused by eggshell have been reported so far. This rare case is reported here, with a review of the literature. (author)

  7. Acute mesenteric ischemia and duodenal ulcer perforation: a unique double pathology

    Directory of Open Access Journals (Sweden)

    Haruna Lois

    2012-10-01

    Full Text Available Abstract Background Acute mesenteric ischaemia and duodenal perforation are surgical emergencies with serious consequences. Patients presenting with acute mesenteric ischaemia alone face a high mortality rate as high as 60% whereas those presenting with peptic ulcer perforation the mortality rates range from 6-14%. There are very few reported cases of patients presenting with this dual pathology. Case presentation We report a unique case of a 53 year old Italian lady who presented with acute mesenteric ischaemia and duodenal perforation. This is the first report of massive bowel ischaemia and duodenal perforation with no apparent underlying common pathophysiology leading to this presentation. Conclusion Early management in the intensive care unit and appropriate surgical intervention maximised the patient’s chances of survival despite the poor prognosis associated with her dual pathology. The rare pathology of the patient described can be explained by two possible hypotheses: peptic ulcer disease causing duodenal ulceration, which precipitated ischaemic infarction of the small bowel. The second hypothesis is the patient developed a stress related ulcer following ischaemic bowel infarction secondary to arterial thrombosis.

  8. Experimental investigation of the unsteady one-phase flow through perforated plates

    International Nuclear Information System (INIS)

    Casadei, F.

    1982-07-01

    The flow of the coolant through the perforated dip-plate during a hypothetical core-disruptive accident in a sodium-cooled fast breeder reactor was simulated in a one-dimensional model. Several experiments with water as fluid and with various perforation ratios of the dip-plate and different initial heights of the fluid head over the dip plate were run. The pressure drop through the dip-plate and the forces acting on the dip-plate and on the upper plug of the reactor vessel in a wide range of the Reynolds and Strouhal numbers were measured. The flow pattern downstreams the perforated plate was filmed with high-speed cameras. The resistance coefficients for the unsteady flow of the coolant through the perforated plate were obtained as a function of the acceleration. The forces acting on the upper plug and their time integral were compared with those acting on the dip-plate. Finally, using the high-speed film pictures the formation of fluid jets downstream the dip-plate was investigated. (orig.) [de

  9. Prediction of inelastic behavior and creep-fatigue life of perforated plates

    International Nuclear Information System (INIS)

    Igari, Toshihide; Yamauchi, Masafumi; Nomura, Shinichi.

    1992-01-01

    Prediction methods of macroscopic and local stress-strain behaviors of perforated plates in plastic and creep regime are proposed in this paper, and are applied to the creep-fatigue life prediction of perforated plates. Both equivalent-solid-plate properties corresponding to the macroscopic behavior and the stress-strain concentration around a hole were obtained by assuming the analogy between plasticity and creep and also by extending the authors' proposal in creep condition. The perforated plates which were made of Hastelloy XR were subjected to the strain-controlled cyclic test at 950degC in air in order to experimentally obtain the macroscopic behavior such as the cyclic stress-strain curve and creep-fatigue life around a hole. The results obtained are summarized as follows. (1) The macroscopic behavior of perforated plates including cyclic stress-strain behavior and relaxation is predictable by using the proposed method in this paper. (2) The creep-fatigue life around a hole can be predicted by using the proposed method for stress-strain concentration around a hole. (author)

  10. Case Report: Rectal perforation during CT colonography [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Marianna Zukiwskyj

    2016-03-01

    Full Text Available Introduction Computer tomography colonoscopy (CTC is an increasingly prevalent procedure for the investigation of colorectal symptoms, or as a component of colorectal cancer screening.  It is considered a low risk procedure, however colonic perforation is a recognized significant complication.   Case Report We report the case of an 81-year-old female patient who underwent CTC after failed optical colonoscopy as part of routine colorectal cancer screening.  Perforation of the rectum with surrounding pararectal air was confirmed on CTC.  The patient had minimal symptoms and was treated successful non-operatively with bowel rest and antibiotics.   Conclusion Perforation sustained during CTC is an uncommon complication.  The incidence of perforation during CTC is still lower than that during optical colonoscopy.  In the absence of significant abdominal signs and symptoms, this rare complication may be successfully managed non-operatively.

  11. CLINICAL STUDY OF APPENDICULAR PERFORATION IN A TERTIARY CARE HOSPITAL

    OpenAIRE

    Venkata Anantha Lakshmi Manabala; Krishna Mohan Narayanrao

    2016-01-01

    INTRODUCTION Acute Appendicitis is the commonest abdominal surgical emergency in young adults all over the world. In early 1900s, Ochsner in Chicago and Sherren at the London Hospital were both advocates of conservative treatment in late cases. Appendicular perforation is a serious complication in view of the ensuing peritonitis with the consequent sequelae and morbidity. AIM To study the incidence, morbidity and sequelae of appendicular perforation. MATERIALS & METHODS ...

  12. Subacute Right Ventricle Perforation by Pacemaker Lead Presenting with Left Hemothorax and Shock

    Directory of Open Access Journals (Sweden)

    Julianne Nichols

    2015-01-01

    Full Text Available Cardiac perforation by pacemaker is a rare but potentially fatal complication. Acute perforations occurring within twenty-four hours of insertion of pacemaker can lead to hemopericardium, cardiac tamponade, and death. Hemothorax occurring as an acute complication of pacemaker insertion is reported but extremely rare. Previously, hemothorax and shock as a subacute complication following pacemaker insertion have not been reported. We report the case of an 85-year-old patient who presented with shock from hemothorax caused by pacemaker perforation, two weeks after insertion. Device interrogation showed normal function. Chest X-ray and echocardiogram missed lead dislocation and the diagnosis was made on computed tomogram (CT of the chest. Following surgical repair, a new ventricular pacemaker was placed transvenously in the right ventricular septum. This case illustrates that CT scan of the chest should be performed in all patients in whom cardiac perforation by pacemaker is suspected but not diagnosed on chest X-ray and echocardiogram. Normal functioning of pacemaker on device interrogation does not exclude perforation.

  13. Segmental resection with primary anastomosis is not always safe in splenic flexure perforation.

    Science.gov (United States)

    Weledji, Elroy P; Mokake, Martin D; Sinju, Motaze

    2016-01-16

    Familial adenomatous polyposis (FAP) is caused by a rare mutation of the adenomatous polyposis coli gene on Chromosome 5q. The risk of colorectal cancer in patients with FAP is nearly 100% and intensive endoscopic surveillance or prophylactic colectomy are mandatory. If extensive endoscopic surveillance is chosen, there is a cumulative risk of perforation and bleeding especially after polypectomy. We discussed the problems and options in the management of the late diagnosis of an iatrogenic perforation of the splenic flexure complicating endoscopic surveillance in FAP. We present a 35-year-old black African man with FAP who sustained a splenic flexure perforation following a colonoscopic polypectomy of a suspicious lesion. He underwent a splenic flexure resection and primary anastomosis that dehisced and the patient benefited from an emergency definitive colectomy and ileorectal anastomosis. Resection with primary anastomosis following iatrogenic perforation of the splenic flexure is not safe because of a high chance of anastomotic dehiscence. Following a late diagnosis in an unstable patient exteriorization of the perforation as a stoma is a better option prior to a definitive prophylactic colectomy.

  14. Free vibration analysis of perforated plate with square penetration pattern using equivalent material properties

    Energy Technology Data Exchange (ETDEWEB)

    Jhung, Myung Ho [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Jeong, Kyeong Hoon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-06-15

    In this study, the natural frequencies of the perforated square plate with a square penetration pattern are obtained as a function of ligament efficiency using the commercial finite-element analysis code ANSYS. In addition, they are used to extract the effective modulus of elasticity under an assumption of a constant Poisson's ratio. The effective modulus of elasticity of the fully perforated square plate is applied to the modal analysis of a partially perforated square plate using a homogeneous finite-element analysis model. The natural frequencies and the corresponding mode shapes of the homogeneous model are compared with the results of the detailed finite-element analysis model of the partially perforated square plate to check the validity of the effective modulus of elasticity. In addition, the theoretical method to calculate the natural frequencies of a partially perforated square plate with fixed edges is suggested according to the Rayleigh-Ritz method.

  15. EVALUAT I ON OF VARIOUS PROGNOSTIC FACTORS IN PERFORATIVE PERITONITIS MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Sarada

    2015-09-01

    Full Text Available Peritonitis is one of the major problems confronting the surgeons in day to day practice. Despite many advances in understanding pathophysiology, mortality rate of diffuse suppurative peritonitis remains high. A prospective study, with prior institutional ethics committee approval, involving 100 patients of perforative peritonitis is done to assess the vari ous prognostic factors in management of generalized peritonitis. Role of age, gender, duration, type of perforation, associated systemic factors are studied in relation to morbidity and mortality in the outcome of management of peritonitis. Elderly age, il eal perforations, delay in presentation of more than 24 hours and associated shock on day one are found to have bad prognosis

  16. The use of endoluminal vacuum (E-Vac) therapy in the management of upper gastrointestinal leaks and perforations.

    Science.gov (United States)

    Smallwood, Nathan R; Fleshman, James W; Leeds, Steven G; Burdick, J S

    2016-06-01

    Upper intestinal leaks and perforations are associated with high morbidity and mortality rates. Despite the growing experience using endoscopically placed stents, the treatment of these leaks and perforations remain a challenge. Endoluminal vacuum (E-Vac) therapy is a novel treatment that has been successfully used in Germany to treat upper gastrointestinal leaks and perforations. There currently are no reports on its use in the USA. E-Vac therapy was used to treat 11 patients with upper gastrointestinal leaks and perforations from September 2013 to September 2014. Five patients with leaks following sleeve gastrectomy were excluded from this study. A total of six patients were treated with E-Vac therapy; these included: (n = 2) iatrogenic esophageal perforations, (n = 1) iatrogenic esophageal and gastric perforations, (n = 1) iatrogenic gastric perforation, (n = 1) gastric staple line leak following a surgical repair of a traumatic gastric perforation, and (n = 1) esophageal perforation due to an invasive fungal infection. Four patients had failed an initial surgical repair prior to starting E-Vac therapy. All six patients (100 %) had complete closure of their perforation or leak after an average of 35.8 days of E-Vac therapy requiring 7.2 different E-Vac changes. No deaths occurred in the 30 days following E-Vac therapy. One patient died following complete closure of his perforation and transfer to an acute care facility due to an unrelated complication. There were no complications directly related to the use of E-Vac therapy. Only one patient had any symptoms of dysphagia. This patient had severe dysphagia from an esophagogastric anastomotic stricture prior to her iatrogenic perforations. Following E-Vac therapy, her dysphagia had actually improved and she could now tolerate a soft diet. E-Vac therapy is a promising new method in the treatment of upper gastrointestinal leaks and perforations. Current successes need to be validated through future

  17. Perforation of the sinus membrane during sinus floor elevation

    DEFF Research Database (Denmark)

    von Arx, Thomas; Fodich, Ivo; Bornstein, Michael M

    2014-01-01

    PURPOSE: To analyze the frequency of perforation of the sinus membrane during maxillary sinus floor elevation (SFE) and to assess possible risk factors. MATERIALS AND METHODS: Seventy-seven cases of SFE performed with a lateral window approach were evaluated retrospectively. Clinical and radiogra......PURPOSE: To analyze the frequency of perforation of the sinus membrane during maxillary sinus floor elevation (SFE) and to assess possible risk factors. MATERIALS AND METHODS: Seventy-seven cases of SFE performed with a lateral window approach were evaluated retrospectively. Clinical...

  18. Semiconductor physics

    CERN Document Server

    Böer, Karl W

    2018-01-01

    This handbook gives a complete survey of the important topics and results in semiconductor physics. It addresses every fundamental principle and most research topics and areas of application in the field of semiconductor physics. Comprehensive information is provided on crystalline bulk and low-dimensional as well as amporphous semiconductors, including optical, transport, and dynamic properties.

  19. Perforated Duodenal Ulcer: Has Anything Changed?

    Science.gov (United States)

    Koskensalo, Selja; Leppäniemi, Ari

    2010-04-01

    To assess the current management and outcome of perforated duodenal peptic ulcer managed with open repair, a focused analysis was conducted, excluding gastric, traumatic and iatrogenic perforations. A retrospective study of a 6-year period identified 61 patients. Mean age was 59 (range 19-87) years and 33 (54%) were male. Medical history included nonsteroidal anti-inflammatory drugs in 46%, smoking in 30%, atherosclerosis in 26% and excessive alcohol use in 23%. Generalized abdominal tenderness was recorded in 64% of the cases. The mean (SD) C-reactive protein value was 100 (141) g/l and white blood cell count was 12.8 (7.9) E9/l. Plain abdominal X-ray was positive for air in 87% (41/47) and CT scan in 86% (18/21). Four patients (7%) were operated without radiological imaging. There were 31 patients (51%) with a delay of 24 h or more from the start of symptoms to surgery. The mean (SD) delay from admission to surgery was 9 (3) (range 3-12) h. The treatment consisted of open suture repair in 92%, peritoneal lavage in 92%, external drainage in 80% and nasogastric decompression in 92%. The overall hospital mortality and morbidity rates were 11 and 21%, respectively. The duodenal suture leak rate was 7% and intra-abdominal abscess rate was 2%. The majority of patients with perforated duodenal ulcer can be diagnosed with conventional clinical and radiological methods, and treated according to established surgical principles. The mortality and duodenal morbidity rates have remained unchanged for the last decade. Shortening preoperative delay could improve the prognosis.

  20. Foreign body causing perforation of the appendix in an African boy ...

    African Journals Online (AJOL)

    Abstract. Foreign bodies in the appendix are a rare but well described clinical entity and may cause perforation. Presented here is the case of a 13yr old Ugandan boy who had features of acute appendicitis, was sent for appendicectomy and during the operation was found to have perforation of the appendix due to a seed.

  1. Case report of idiopathic cecal perforation presenting as acute appendicitis on ultrasound

    Directory of Open Access Journals (Sweden)

    Calista Harbaugh

    2016-08-01

    Full Text Available Cecal perforation is an uncommon phenomenon in a pediatric population. It has been linked to a number of underlying medical conditions, which may result in focal inflammation or relative ischemia including hematologic malignancy, infection, and inflammatory bowel disease. We present an otherwise healthy 16-year-old male diagnosed with acute uncomplicated appendicitis on ultrasound, who was found to have cecal perforation with normal appendix intraoperatively, ultimately requiring ileocectomy. With this report, we aim to present the numerous pathophysiologic etiologies of cecal perforation, and to promote a comprehensive differential diagnosis despite the clinical and radiologic findings consistent with uncomplicated appendicitis.

  2. Bladder perforation owing to a unipolar coagulating device.

    Science.gov (United States)

    Pakter, J; Budnick, L D

    1981-09-15

    A report on a patient who sustained a burn and perforation of the urinary bladder from visible sparks emanating from a unipolar coagulating device during the couse of laparoscopic sterilization is presented. It is the first report of urinary bladder burns using a unipolar coagulating device. A 24-year-old woman, gravida 10, para 3, abortus 7, underwent a laparoscopic sterilization with a unipolar coagulating device. As the physician was finishing the coagulation, a spark from the device caused a 1-2 cm burn with a central area of perforation into the urinary bladder. Conservative treatment was recommended, and consisted of Foley catheterization and drainage for 5 days. Initial urine culture revealed Klebsiella species, and oral ampicillin was prescribed. Hematuria was noted throughout the patient's hospitalization, and blood clots were present in the urine on Day 2 postoperation. The patient had no abdominal or flank pain, was afebrile, and had a stable hemoglobin level during the hospital stay. Cystography was performed on Day 5 postoperatively and demonstrated no perforation. Foley catheter was removed. Patient was discharged 2 days later and remains in good health 3 months postoperatively.

  3. Segmental absence of intestinal musculature with metachronous bowel perforations in an infant

    Directory of Open Access Journals (Sweden)

    Noboru Oyachi

    2018-03-01

    Full Text Available Segmental absence of intestinal musculature is a rare condition. A female patient was born at 39 weeks gestational age with birth weight of 2,900 g. The patient was prenatally diagnosed as having segmental bowel distension in the fetal stage. She manifested bilious emesis with abdominal distension at day 1. Although excretion of viscous meconium was observed by gastrografin enema, gastrointestinal perforation developed. Emergency laparotomy and peritoneal drainage was required at that time and further laparotomy was performed on day 15. Multiple perforations were recognized discontinuously from the jejunum to the transverse colon, and jejunostomy was constructed. Additional bowel perforations occurred and re-exploration was required at day 43. We found newly formed small perforations in the proximal jejunum, ileum and the transverse colon and a tube jejunostomy and a colostomy were established. The patient required prolonged TPN management, which induced correlated cholestasis and liver failure, and died at day 143. Pathologic findings showed partial hypoplasia of the intrinsic muscle layer in the small intestine and diagnosed as segmental absence of intestinal musculature. Her disorder was unusual in its presentation, which included prenatal bowel dilatation, metachronous superimposed bowel perforation, and extensive discrete lesions from the jejunum to the transverse colon.

  4. Small bowel perforation without tumor recurrence after radiotherapy for cervical carcinoma: report of seven cases.

    Science.gov (United States)

    Yamashita, Hideomi; Nakagawa, Keiichi; Tago, Masao; Igaki, Hiroshi; Shiraishi, Kenshirou; Nakamura, Naoki; Sasano, Nakashi; Yamakawa, Sen; Ohtomo, Kuni

    2006-04-01

    We describe the clinical presentation, evaluation, management and outcome of patients experiencing small bowel perforation following radiation therapy for cervical cancer. A database consisting of 95 Japanese women with stage 0-4 A cervix cancer treated between 1991 and 2004 contained seven patients (7.4%) with small bowel perforation. The median age at the time of perforation was 72.5 years (range 62-78). The median time from completion of radiotherapy to perforation was 6 months (range 2-58). Surgery (one small bowel resection and anastomosis with diversion; six small bowel resection and anastomosis) was performed immediately in all seven patients. One of seven patients died of small bowel perforation (i.e. mortality rate was 14%). Bowel adhesion was detected during the operation in only three cases (43%). Signs of peritonitis were absent in six cases (86%). Severe abdominal pain was seen in all seven patients. The perforation site was ileum in all seven cases. In all patients, pathological changes were compatible with postirradiation injury of the gastrointestinal tract. The presenting complaints of patients with bowel perforation following radiotherapy vary, and signs of peritonitis may be absent. Emergency physicians must be alert for these complications in patients who have been treated with radiotherapy.

  5. Impact of thermal and intermediate energy neutrons on the semiconductor memories for the CERN accelerators

    CERN Document Server

    Cecchetto, Matteo; Gerardin, Simone

    A wide quantity of SRAM memories are employed along the Large Hadron Collider (LHC), the main CERN accelerator, and they are subjected to high levels of ionizing radiations which compromise the reliability of these devices. The Single Event Effect (SEE) qualification for components to be used in the complex high-energy accelerator at CERN relies on the characterization of two cross sections: 200-MeV protons and thermal neutrons. However, due to cost and time constraints, it is not always possible to characterize the SEE response of components to thermal neutrons, which is often regarded as negligible for components without borophosphosilicate glass (BPSG). Nevertheless, as recent studies show, the sensitivity of deep sub-micron technologies to thermal neutrons has increased owing to the presence of Boron 10 as a dopant and contact contaminant. The very large thermal neutron fluxes relative to high-energy hadron fluxes in some of the heavily shielded accelerator areas imply that even comparatively small therm...

  6. Discriminating between simple and perforated appendicitis

    NARCIS (Netherlands)

    Bröker, Mirelle E. E.; van Lieshout, Esther M. M.; van der Elst, Maarten; Stassen, Laurents P. S.; Schepers, Tim

    2012-01-01

    Several studies have been performed in order to diagnose an acute appendicitis using history taking and laboratory investigations. The aim of this study was to create a model for the identification of a perforated appendicitis. All consecutive patients who have undergone an appendectomy in the

  7. Infantile perforated appendicitis: A forgotten diagnosis

    Directory of Open Access Journals (Sweden)

    Katherine W. Gonzalez

    2015-04-01

    Full Text Available Acute appendicitis in the infant is a rare surgical diagnosis despite its frequency in older patients. The clinical presentation is often vague and can be misleading. We present the successful diagnosis and treatment of a 3 month old female with perforated appendicitis.

  8. Management of perforated peptic ulcer in patients at a teaching hospital.

    Science.gov (United States)

    Bin-Taleb, Ali K; Razzaq, Riyadh A; Al-Kathiri, Zaki O

    2008-02-01

    To explore and analyze the current status in management of patients with perforated peptic ulcers (PPU). A retrospective study carried out at the Surgical Department, Al-Gamhouria Teaching Hospital, Aden, Yemen. Patients admitted with perforated benign peptic ulcers from January 1997 to December 2006 were included in the study. A total of 156 patients, 138 (88.5%) male and 18 (11.5%) female, with an overall mean age of 39.08 years (range 14-75 years) and a higher frequency of PPU was noted in patients 21-40 years (58.3%). The perforated duodenal ulcer and perforated gastric ulcer ratio was 4.38:1. The mean time of presentation was 16.5 hours, and operative intervention after admission was 5.25 hours. Simple perforation closure was used in 91.7% of the patients. Postoperative complication rate was 41% (statistically significant in cases admitted later than 12 hours), wound sepsis making the majority at 55.2%, 6 deaths (3.9%), the correlation with presentation time was not significant. The overall mean post-operative hospitalization period was 12.76 days; 14.7% of the patients stayed more than 3 weeks. Younger patients (21-40 years) were frequently affected. Emphasis should be placed on shortening the time to surgery. Simple closure remains the selected treatment in the majority of patients. Overall post-operative mortality was low (3.9%). Improving the surgical skills, wound care, administrative regulations, hospital environment, and equipment are needed to reduce the high rate of complications.

  9. Anatomical study of terminal peroneal artery perforators and their clinical applications

    Directory of Open Access Journals (Sweden)

    Rajendran Purushothaman

    2013-01-01

    Full Text Available Introduction: Peroneal artery gives off plenty of perforators that pass through fascial septum to supply skin and tenosynovium of peroneal muscles. Aim: The aim of this study was to study the anatomical basis of perforators from terminal part of peroneal artery axiality and to make use of this knowledge in reconstructing defects of posterior heel with the advantage of reducing the morbidity of conventional flaps. Materials and Methods: Our study was conducted at Department of Plastic surgery, Madras Medical College and Rajiv Gandhi Government General Hospital, India. We have carried out eleven cadaver dissections (from six cadavers-four fresh cadavers and two preserved cadavers and delineated all septocutaneous and septosynovial perforators of distal peroneal axis and studied their relation with short saphenous vein (SSV and sural nerve. Using this anatomical knowledge we have fashioned perforator based flaps in 13 patients (three propeller, four V-Y advancement, six tenosynovial flaps for reconstruction of defects over tendo achilles and pericalcaneal region . Results: In all cases, SSV and sural nerve were preserved and donor site was closed primarily. No total flap loss was noted. Conclusion: Perforator based flaps from distal most part of peroneal artery provide a good and reliable method for reconstruction of pericalcaneal and tendo achilles region defects with preservation of SSV and sural nerve. It also avoids contour deformity of the grafted donor site of the classical lateral calcaneal artery axial flap.

  10. Repair of post polypectomy colonic perforation by Endoclip: a case report

    Directory of Open Access Journals (Sweden)

    Ahmad Hormati

    2015-10-01

    Full Text Available A 73-year-old woman was admitted to evaluate for iron deficiency anemia, increased serum creatinine, and ascites. Her colonoscopy revealed a polyp at the junction of sigmoid and descending colon, and after polypectomy, a 6 mm colonic perforation was seen. The perforation was detected by radiography and CT scan; and beside conservative management and antibiotics, her perforation was closed by using Endoclip. The patient was observed and discharged from hospital without any surgery 5 days later, and in follow-up there was no problem regarding perforation. Resumo: Mulher, 73 anos, internada para avaliação para anemia ferropriva, com aumento da creatinina sérica e ascite. A colonoscopia revelou um pólipo na junção dos colos sigmoide e descendente e, em seguida à polipectomia, foi observada uma perfuração de 6 mm no cólon, comprovada por radiografias e tomografia computadorizada. Além do tratamento conservador e da antibioticoterapia, a perfuração foi ocluída com Endoclip. A paciente ficou sob observação e recebeu alta do hospital sem qualquer cirurgia 5 dias mais tarde. Durante o seguimento, não foram observados problemas com relação à perfuração. Keywords: Polypectomy, Colonic perforation, Endoclip, Palavras-chave: Polipectomia, Perfuração de cólon, Endoclip

  11. Marginal ulcer perforation: a single center experience.

    Science.gov (United States)

    Natarajan, S K; Chua, D; Anbalakan, K; Shelat, V G

    2017-10-01

    Marginal ulcer (MU) is defined as ulcer on the jejunal side of the gastrojejunostomy (GJ) anastomosis. Most MUs are managed medically but those with complications like bleeding or perforation require intervention. It is recommended that GJ anastomosis be revised in patients with MU perforation (MUP). The aim of this case series is to study the clinical presentation and management of MUP. Three hundred and thirty-two patients who underwent emergency surgery for perforated peptic ulcer at a single center were studied over a period of 5 years. Nine patients (2.7 %) presented with MUP. GJ was previously done for either complicated peptic ulcer (n = 4) or for suspected gastric malignancy (n = 5). Two patients had previously completed H. pylori therapy. None of the patients presented with septic shock. MU was on the jejunal side of GJ in all patients. The median MUP size was 10 mm. Four patients (44.4 %) had omental patch repair, three (33.3 %) had primary closure, and one each had revision of GJ and jejunal serosal patch repair. There were no leaks, intra-abdominal abscess or reoperation and no malignancies. MUP patients do not present with septic shock. Omental patch repair or primary closure is sufficient enough. Revision of Billroth-II-GJ into Roux-en-Y-GJ is not mandatory.

  12. Perforated coins from graves at the Viminacium necropolis of Više Grobalja

    Directory of Open Access Journals (Sweden)

    Vojvoda Mirjana D.

    2015-01-01

    Full Text Available A common problem that occurs when interpreting finds of perforated Roman coins is whether they had been perforated in Roman times or later. Hence, the specimens that originate from an undisturbed archaeological context, as is the case with finds from the Viminacium necropolis of Više Grobalja, are indispensable. A total of 47 perforated coins were discovered: 31 with a single and 16 with three perforations. The analysis of the context of the finds, in some specimens, allows the confident assertion that they had constituted a part of jewellery. [Projekat Ministarstva nauke Republike Srbije, br. 47018: IRS - Viminacium, Roman city and military legion camp - research of the material and non-material culture of inhabitants using the latest technologies of remote detection, geophysics, GIS, digitalisation and 3D visualisation

  13. LaPlace's law revisited: Cecal perforation as an unusual presentation of pancreatic carcinoma

    Directory of Open Access Journals (Sweden)

    Cason Frederick D

    2007-02-01

    Full Text Available Abstract Background Pancreatic cancer is often locally and distally aggressive, but initial presentation as cecal perforation is uncommon. Case presentation We describe a patient presenting with pneumoperitoneum, found at initial exploration to have a cecal perforation believed to be secondary to a large cecal adenoma, after palpation of the remainder of the colon revealed hard stool but no distal obstruction. Postoperatively, however, the patient progressed to large bowel obstruction and upon reexploration, a mass could now be delineated, encompassing the splenic flexure, splenic hilum, and distal pancreas. Histological evaluation determined this was locally invasive pancreatic adenocarcinoma, and therefore the true etiology of the original cecal perforation. Conclusion Any perforation localized to the cecum must be highly suspicious for a distal obstruction, as dictated by the law of LaPlace.

  14. Electrical and optical analyses of low fluence fast neutron damage to JFETs

    International Nuclear Information System (INIS)

    Hoffmann, A.; Charles, J.P.; Kerns, S.E.; Kerns, D.V. Jr.; Bardonnie, M. de la; Mialhe, P.

    1999-01-01

    The effects of fast neutron irradiation (30 MeV) on silicon n-channel JFETs are studied. Electrical parameters of the gate-channel junction are analysed at 3 fluences: 4,06*10 10 , 8,12*10 10 and 1,22*10 11 n/cm 2 for a flux of 2,82*10 6 n/s*cm 2 and using a custom software. Electrical parameter changes are attributed to bulk semi-conductor defects. Irradiation effects on passivation overlayers are evacuate using analysis of gate-channel junction electroluminescence. This study shows that even for low neutron fluences (10 11 n/cm 2 ), n-channel JFETs, characterized in direct conducting mode and submitted to neutron radiation, present a decrease in the reverse saturation current associated with recombination. (A.C.)

  15. Free vibration analysis of perforated plate with square penetration pattern using equivalent material properties

    Directory of Open Access Journals (Sweden)

    Myung Jo Jhung

    2015-06-01

    Full Text Available In this study, the natural frequencies of the perforated square plate with a square penetration pattern are obtained as a function of ligament efficiency using the commercial finite-element analysis code ANSYS. In addition, they are used to extract the effective modulus of elasticity under an assumption of a constant Poisson's ratio. The effective modulus of elasticity of the fully perforated square plate is applied to the modal analysis of a partially perforated square plate using a homogeneous finite-element analysis model. The natural frequencies and the corresponding mode shapes of the homogeneous model are compared with the results of the detailed finite-element analysis model of the partially perforated square plate to check the validity of the effective modulus of elasticity. In addition, the theoretical method to calculate the natural frequencies of a partially perforated square plate with fixed edges is suggested according to the Rayleigh–Ritz method.

  16. Pneumoperitoneum without Intestinal Perforation in a Neonate: Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Prabhavathi Gummalla

    2017-01-01

    Full Text Available Pneumoperitoneum in a preterm neonate usually indicates perforation of the intestine and is considered a surgical emergency. However, there are cases of pneumoperitoneum with no evidence of rupture of the intestine reported in the literature. We report a case of pneumoperitoneum with no intestinal perforation in a preterm neonate with respiratory distress syndrome who was on high frequency oscillatory ventilation (HFOV. He developed bilateral pulmonary interstitial emphysema with localized cystic lesion, likely localized pulmonary interstitial emphysema, and recurrent pneumothoraces. He was treated with dexamethasone to wean from the ventilator. Pneumoperitoneum developed in association with left sided pneumothorax following mechanical ventilation and cardiopulmonary resuscitation. Pneumoperitoneum resolved after the pneumothorax was resolved with chest tube drainage. He died from acute cardiorespiratory failure. At autopsy, there was no evidence of intestinal perforation. This case highlights the fact that pneumoperitoneum can develop secondary to pneumothorax and does not always indicate intestinal perforation or require exploratory laparotomy.

  17. Experimental investigation of sound absorption properties of perforated date palm fibers panel

    International Nuclear Information System (INIS)

    Elwaleed, A K; Nikabdullah, N; Nor, M J M; Tahir, M F M; Zulkifli, R

    2013-01-01

    This paper presents the sound absorption properties of a natural waste of date palm fiber perforated panel. A single layer of the date palm fibers was tested in this study for its sound absorption properties. The experimental measurements were carried out using impedance tube at the acoustic lab, Faculty of Engineering, Universiti Kebangsaan Malaysia. The experiment was conducted for the panel without air gap, with air gap and with perforated plate facing. Three air gap thicknesses of 10 mm, 20 mm and 30 mm were used between the date palm fiber sample and the rigid backing of the impedance tube. The results showed that when facing the palm date fiber sample with perforated plate the sound absorption coefficient improved at the higher and lower frequency ranges. This increase in sound absorption coincided with reduction in medium frequency absorption. However, this could be improved by using different densities or perforated plate with the date palm fiber panel.

  18. Pseudolipomatosis in Endometrial Specimens Does Not Represent Uterine Perforation.

    Science.gov (United States)

    Heller, Alexis

    2017-02-01

    Specimens of endometrial biopsies can sometimes present with an artifact within blood, composed of optically clear vacuoles mimicking adipose tissue, pseudolipomatosis. This artifact can be mistaken for adipose tissue and lead to an overdiagnosis of uterine perforation. We describe the case of pseudolipomatosis seen within the evacuated products of conception from a missed abortion. Areas of vacuolization in the blood clot mimicked adipose tissue. However, the vacuoles varied in size and did not contain adipocytes. Familiarity with this artifact will lead to avoidance of overdiagnosis of adipose tissue and uterine perforation in curettage specimens.

  19. Colonic perforation in the first few hours of life associated with rhizomelic chondrodysplasia punctata.

    Science.gov (United States)

    Fairbanks, Timothy; Emil, Sherif

    2005-08-01

    Rhizomelic chondrodysplasia punctata (RCP), a rare autosomal recessive disease characterized by a disorder of peroxisome metabolism, has been shown to affect multiple organ systems. A neonate presenting with a colonic perforation in the first few hours of life was subsequently diagnosed with RCP. A literature search revealed no previous reports of intestinal perforation associated with RCP. Intestinal perforation should be added to the list of medical complications associated with RCP.

  20. Thermal neutron detection using a silicon pad detector and {sup 6}LiF removable converters

    Energy Technology Data Exchange (ETDEWEB)

    Barbagallo, Massimo [Istituto Nazionale di Fisica Nucleare, Sezione di Bari (Italy); Cosentino, Luigi; Marchetta, Carmelo; Pappalardo, Alfio; Scire, Carlotta; Scire, Sergio; Schillaci, Maria; Vecchio, Gianfranco; Finocchiaro, Paolo [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Catania (Italy); Forcina, Vittorio; Peerani, Paolo [European Commission, Joint Research Centre, Institute of Transuranium Elements, Ispra (Italy); Vaccaro, Stefano [European Commission, Directorate-General for Energy (Luxembourg)

    2013-03-15

    A semiconductor detector coupled with a neutron converter is a good candidate for neutron detection, especially for its compactness and reliability if compared with other devices, such as {sup 3}He tubes, even though its intrinsic efficiency is rather lower. In this paper we show a neutron detector design consisting of a 3 cm Multiplication-Sign 3 cm silicon pad detector coupled with one or two external {sup 6}LiF layers, enriched in {sup 6}Li at 95%, placed in contact with the Si active surfaces. This prototype, first characterized and tested at INFN Laboratori Nazionali del Sud and then at JRC Ispra, was successfully shown to detect thermal neutrons with the expected efficiency and an outstanding gamma rejection capability.

  1. Probe high-Tc Superconductors by neutron scattering

    International Nuclear Information System (INIS)

    Fauque, B.

    2007-10-01

    This research thesis explores two aspects of the phase diagram of high critical temperature superconductors: the evolution of AF correlations and the nature of the pseudo-gap phase. The author presents the problematic associated with these particular semiconductors, describes the neutron diffusion probe used in this study, and presents the three families of semiconductors investigated during this research: Bi 2 Sr 2 CaCu 2 O 8+x , YBa 2 Cu 3 O 6+x and La 2-x Sr x CuO 4 . He reports the results of the investigation of the spin dynamics in the Bi 2 Sr 2 CaCu 2 O 8+x . He reports a detailed investigation of the magnetic cross section associated with different types of non conventional magnetic orders proposed as candidates for the pseudo-gap phase. He reports and comments the results obtained for the pseudo-gap phase for the YBa 2 Cu 3 O 6+x and La 2-x Sr x CuO 4 families. Finally, the author discusses the consequences of the obtained results for the description of the diagram phase of high critical temperature semiconductors

  2. [Peritonitis following gastroduodenal ulcer perforation disease in children: report of 4 cases].

    Science.gov (United States)

    Ndour, O; Bansouda, J; Fall, A F; Alumeti, D M; Diouf, C; Ngom, G; Ndoye, M

    2012-10-01

    Peritonitis due to gastroduodenal ulcer perforation disease is a rare entity in pediatric surgery. In Senegal, no study has been dedicated to ulcer complications in children. The aim of this study was to describe the epidemiology, diagnosis, and treatment of perforated peptic ulcer in patients less than 15 years old. This retrospective study was conducted in the Surgical Emergencies and Paediatric Surgery Department at Aristide Le Dantec University Hospital Center in Dakar, Senegal, during a period of 11 years (January 1999 to December 2010). We found 4 children who presented perforated gastroduodenal ulcer: 3 females and 1 male. The average age of these patients was 9 years (range, 7-14 years). No family history was found. We noted 3 cases of perforated duodenal ulcer and one perforated gastric ulcer. The clinical diagnosis was suspected based on a peritoneal irritation syndrome. A plain x-ray of the abdomen was taken in all patients, which objectified a pneumoperitoneum image in 3 cases. The leukocytosis was constant. Treatment in all patients consisted on pre-, intra-, and postoperative intensive care, supra- and infraumbilical midline laparotomy, which allowed us to perform a debridement-suture of the gap followed by epiploplasty and extensive washing with lukewarm physiologic serum. Adjuvant therapy based on anti-ulcer and antibiotic therapy was initiated. Bacteriological examination of peritoneal fluid isolated a polymicrobial flora. Helicobacter pylori was not isolated. Histological examination of the biopsied perforation edges showed a benign ulcer in all cases. The follow-up endoscopy was performed 4 weeks after surgery and showed cicatrization of the ulcer in all patients. After a mean of 2 years, no recurrence was noted. The gastric or duodenal ulcer in children is rare. It is often discovered at the stage of perforation, a complication for which the essential treatment is surgery. Routine screening would certainly help to reduce the risk of this

  3. The Peptic Ulcer Perforation (PULP) score: a predictor of mortality following peptic ulcer perforation. A cohort study

    DEFF Research Database (Denmark)

    Møller, M H; Engebjerg, M C; Adamsen, S

    2012-01-01

    Accurate and early identification of high-risk surgical patients with perforated peptic ulcer (PPU) is important for triage and risk stratification. The objective of the present study was to develop a new and improved clinical rule to predict mortality in patients following surgical treatment...

  4. Candidiasis, A Rare Cause of Gastric Perforation: A Case Report and Review of Literature.

    Science.gov (United States)

    Ukekwe, F I; Nwajiobi, C; Agbo, M O; Ebede, S O; Eni, A O

    2015-01-01

    Fungi are unusually rare causes of gastric perforation, with most cases of gastric perforation occurring as complications of peptic ulcer disease (PUD), nonsteroidal anti-inflammatory drugs (NSAIDs) and gastric neoplasms. Here, we report the case of a 70-year-old Nigerian male who presented with severe epigastric pain, with no associated history of PUD, NSAIDs use or gastric neoplasm. An emergency exploratory laparotomy was performed and a gastric perforation was discovered and repaired. Histopathological examination of the gastric perforation edge biopsy revealed an intense Candida growth consisting of numerous fungal spores and hyphae invading and destroying the gastric wall. He was subsequently treated with fluconazole antifungal and discharged home after an uneventful postoperative period.

  5. A High Temperature-Tolerant and Radiation-Resistant In-Core Neutron Sensor for Advanced Reactors. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Lei [The Ohio State Univ., Columbus, OH (United States); Miller, Don [The Ohio State Univ., Columbus, OH (United States)

    2015-01-23

    The objectives of this project are to develop a small and reliable gallium nitride (GaN) neutron sensor that is capable of withstanding high neutron fluence and high temperature, isolating gamma background, and operating in a wide dynamic range. The first objective will be the understanding of the fundamental materials properties and electronic response of a GaN semiconductor materials and device in an environment of high temperature and intense neutron field. To achieve such goal, an in-situ study of electronic properties of GaN device such as I-V, leakage current, and charge collection efficiency (CCE) in high temperature using an external neutron beam will be designed and implemented. We will also perform in-core irradiation of GaN up to the highest yet fast neutron fluence and an off-line performance evaluation.

  6. A High Temperature-Tolerant and Radiation-Resistant In-Core Neutron Sensor for Advanced Reactors. Final report

    International Nuclear Information System (INIS)

    Cao, Lei; Miller, Don

    2015-01-01

    The objectives of this project are to develop a small and reliable gallium nitride (GaN) neutron sensor that is capable of withstanding high neutron fluence and high temperature, isolating gamma background, and operating in a wide dynamic range. The first objective will be the understanding of the fundamental materials properties and electronic response of a GaN semiconductor materials and device in an environment of high temperature and intense neutron field. To achieve such goal, an in-situ study of electronic properties of GaN device such as I-V, leakage current, and charge collection efficiency (CCE) in high temperature using an external neutron beam will be designed and implemented. We will also perform in-core irradiation of GaN up to the highest yet fast neutron fluence and an off-line performance evaluation.

  7. Stress state in perforated plates

    International Nuclear Information System (INIS)

    Visner, J.

    1977-01-01

    The method is described of photoelastic measurement of stress concentration factors (s.c.f) in plates perforated by a square, triangular and diagonal grid of circular holes and loaded by uniaxial or biaxial tensile stress. A loading equipment which was developed and its modifications are described. Stress concentration factors found are compared with theoretical and experimental results given in references. (author)

  8. Acute Myocardial Infarction with Simultaneous Gastric Perforation

    Directory of Open Access Journals (Sweden)

    Alon Kaplan

    2017-05-01

    Full Text Available Acute myocardial infarction and perforated peptic ulcer disease with associated peritonitis are both medical emergencies requiring urgent intervention. This patient presented with both emergencies simultaneously. Current literature is devoid of guidance as to which should be addressed initially. A multidisciplinary discussion was conducted leading to a unanimous decision for initiating percutaneous coronary intervention (PCI. After successful PCI, the patient was immediately taken to the operating room for laparoscopic repair of the perforated viscous. Subsequent to the operative repair, the patient became hemodynamically unstable and a repeat electrocardiogram demonstrated complete right coronary occlusion. Shock ensued and the patient died in the intensive care unit despite this plan of care. It is our opinion that this case reveals the need for expert panels to devise decision algorithms for concomitant presentations of life-threatening diseases.

  9. The new generations of power components will depend on neutron and/or electron bombardment techniques

    International Nuclear Information System (INIS)

    Lilen, H.

    1976-01-01

    Neutron and electron bombardment techniques for materials doping, newly introduced in the fabrication of power semiconductor components: diodes, transistors, thyristors, and triacs are briefly outlined. A neutron bombardment of high purity silicon results in a short-lived 31 Si isotope (from 30 Si) decaying into 31 P. The phosphorus with its five peripheral electrons induces a negative doping (N), and the neutron technique gives a homogeneous doping. Furthermore, silicon bombardment with 1 to 2MeV electrons induces micro-ruptures in the lattice, that act as recombination traps reducing carrier lifetimes. Consequently, gold diffusion techniques can be replaced by electron bombardment with a gain in controlling carrier lifetimes [fr

  10. Distinction between upper and lower gastrointestinal perforation: Usefulness of the periportal free air sign on computed tomography

    International Nuclear Information System (INIS)

    Cho, Hyun Sun; Yoon, Seong Eon; Park, Seong Hoon; Kim, Hyewon; Lee, Young-Hwan; Yoon, Kwon-Ha

    2009-01-01

    Purpose: To evaluate the usefulness of the periportal free air (PPFA) sign on computed tomography (CT) to distinguish upper from lower gastrointestinal (GI) tract perforation. Materials and methods: During a 30-month period, we retrospectively analyzed abdominal CT images of 53 consecutive patients with surgically proven GI tract perforation. We divided the patients into two groups, i.e. upper and lower GI tract perforation groups. According to the distribution of free air, we divided the peritoneal cavity into supramesocolic compartment and inframesocolic compartment. We observed the presence or absence of free air in each compartment in each group. When there was free air in the periportal area, it was defined as periportal free air (PPFA) and the sign was positive. To evaluate the usefulness of the PPFA sign, we compared the PPFA sign with the falciform ligament sign and the ligamentum teres sign, both of which are well-known CT signs of pneumoperitoneum. Statistical analyses were performed with univariate and multivariate analyses using SPSS version 11.5 for significant findings among the CT signs. Results: Free air was seen in supramesocolic compartment in 29 of 30 (97%) patients in the upper GI perforation group and in 17 of 23 (74%) in the lower GI perforation group. Free air in inframesocolic compartment did not show significant difference in either group (p = .16). The PPFA sign was seen in 28 of 30 (93%) patients with upper GI tract perforation, but in only 8 of 23 (35%) patients with lower GI tract perforation (p < .0001). The falciform ligament sign was seen in 24 of 30 (80%) patients with upper GI tract perforation and in 10 of 23 (43%) patients with lower GI tract perforation (p = .020). The ligamentum teres sign was seen in 16 of 30 (53%) patients with upper GI tract perforation and in 2 of 23 (8%) patients with lower GI tract perforation (p = .008). Multivariate logistic regression analysis showed that the PPFA sign was the only variable, which

  11. Distinction between upper and lower gastrointestinal perforation: Usefulness of the periportal free air sign on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hyun Sun; Yoon, Seong Eon; Park, Seong Hoon; Kim, Hyewon; Lee, Young-Hwan [Department of Radiology, Wonkwang University School of Medicine, 344-2 Sinyong-dong, Iksan, Jeonbuk 570-711 (Korea, Republic of); Yoon, Kwon-Ha [Department of Radiology, Wonkwang University School of Medicine, 344-2 Sinyong-dong, Iksan, Jeonbuk 570-711 (Korea, Republic of)], E-mail: khy1646@wonkwang.ac.kr

    2009-01-15

    Purpose: To evaluate the usefulness of the periportal free air (PPFA) sign on computed tomography (CT) to distinguish upper from lower gastrointestinal (GI) tract perforation. Materials and methods: During a 30-month period, we retrospectively analyzed abdominal CT images of 53 consecutive patients with surgically proven GI tract perforation. We divided the patients into two groups, i.e. upper and lower GI tract perforation groups. According to the distribution of free air, we divided the peritoneal cavity into supramesocolic compartment and inframesocolic compartment. We observed the presence or absence of free air in each compartment in each group. When there was free air in the periportal area, it was defined as periportal free air (PPFA) and the sign was positive. To evaluate the usefulness of the PPFA sign, we compared the PPFA sign with the falciform ligament sign and the ligamentum teres sign, both of which are well-known CT signs of pneumoperitoneum. Statistical analyses were performed with univariate and multivariate analyses using SPSS version 11.5 for significant findings among the CT signs. Results: Free air was seen in supramesocolic compartment in 29 of 30 (97%) patients in the upper GI perforation group and in 17 of 23 (74%) in the lower GI perforation group. Free air in inframesocolic compartment did not show significant difference in either group (p = .16). The PPFA sign was seen in 28 of 30 (93%) patients with upper GI tract perforation, but in only 8 of 23 (35%) patients with lower GI tract perforation (p < .0001). The falciform ligament sign was seen in 24 of 30 (80%) patients with upper GI tract perforation and in 10 of 23 (43%) patients with lower GI tract perforation (p = .020). The ligamentum teres sign was seen in 16 of 30 (53%) patients with upper GI tract perforation and in 2 of 23 (8%) patients with lower GI tract perforation (p = .008). Multivariate logistic regression analysis showed that the PPFA sign was the only variable, which

  12. Experimental Studies on Wave Interactions of Partially Perforated Wall under Obliquely Incident Waves

    Directory of Open Access Journals (Sweden)

    Jong-In Lee

    2014-01-01

    Full Text Available This study presents wave height distribution in terms of stem wave evolution phenomena on partially perforated wall structures through three-dimensional laboratory experiments. The plain and partially perforated walls were tested to understand their effects on the stem wave evolution under the monochromatic and random wave cases with the various wave conditions, incident angle (from 10 to 40 degrees, and configurations of front and side walls. The partially perforated wall reduced the relative wave heights more effectively compared to the plain wall structure. Partially perforated walls with side walls showed a better performance in terms of wave height reduction compared to the structure without the side wall. Moreover, the relative wave heights along the wall were relatively small when the relative chamber width is large, within the range of the chamber width in this study. The wave spectra showed a frequency dependency of the wave energy dissipation. In most cases, the existence of side wall is a more important factor than the porosity of the front wall in terms of the wave height reduction even if the partially perforated wall was still effective compared to the plain wall.

  13. The Houdini effect--an unusual case of blunt abdominal trauma resulting in perforative appendicitis.

    LENUS (Irish Health Repository)

    O'Kelly, F

    2012-03-01

    We present a unique case of perforative appendicitis that occurred in an adult following blunt abdominal trauma. This case represents the first such reported case from Ireland. It also represents a modern practical example of Laplace\\'s theory of the effect of increased pressure on colonic wall tension leading to localized perforation, and serves to highlight not only the importance in preoperative imaging for blunt abdominal trauma, but also the importance of considering appendiceal perforation.

  14. Two cases of bowel perforation associated with sunitinib treatment for renal cell carcinoma.

    Science.gov (United States)

    Hoshino, Yoshinori; Hasegawa, Hirotoshi; Ishii, Yoshiyuki; Endo, Takashi; Ochiai, Hiroki; Okabayashi, Koji; Kaneko, Gou; Mikami, Shuji; Mukai, Makio; Oya, Mototsugu; Kitagawa, Yuko

    2012-08-01

    Sunitinib, a multitargeted tyrosine kinase inhibitor, is widely used in the treatment of carcinoma. Adverse events associated with this treatment, including fatigue, diarrhea, and hematotoxicity, have been reported in clinical trials. Bowel perforation is a surgical emergency that requires immediate treatment depending on the location and progression of the tumor. We report 2 cases of bowel perforation during sunitinib treatment. The patients presented with diffuse peritonitis, and emergency exploratory laparotomy was performed. We speculate that the underlying mechanisms were decrease in capillary density of the normal mucosa in case 1 and tumor shrinkage because of sunitinib treatment in case 2. To the best of our knowledge, this is the first study to report the pathological findings implicating bowel perforation due to sunitinib treatment. Further investigations are needed to clarify the risk factors for intestinal perforations associated with sunitinib treatment.

  15. A case of perforating injury of eyeball and traumatic cataract caused by acupuncture

    Directory of Open Access Journals (Sweden)

    Han Shuang

    2016-01-01

    Full Text Available Perforating globe injury is the leading cause of monocular blindness and vision loss. A 58-year-old male was injured by acupuncture needle during acupuncture treatment for his cerebral infarction. To the best of our knowledge, this is the first case report of perforating injury of the eyeball and traumatic cataract caused by acupuncture. The patient was hospitalized due to diagnosis of perforating ocular injury, traumatic cataract, and corneal and iris perforating injury. Moreover, he had to accept treatments of phacoemulsification, anterior vitrectomy along with intraocular lens implantation in the sulcus to improve his visual acuity. As acupuncture therapy has been widely performed for various diseases and achieved highly approval, the aim of this report is to remind acupuncturists operating accurately to avoid unnecessary injury during the treatment process, or the cure can also become the weapon.

  16. A case of perforating injury of eyeball and traumatic cataract caused by acupuncture.

    Science.gov (United States)

    Shuang, Han; Yichun, Kong

    2016-04-01

    Perforating globe injury is the leading cause of monocular blindness and vision loss. A 58-year-old male was injured by acupuncture needle during acupuncture treatment for his cerebral infarction. To the best of our knowledge, this is the first case report of perforating injury of the eyeball and traumatic cataract caused by acupuncture. The patient was hospitalized due to diagnosis of perforating ocular injury, traumatic cataract, and corneal and iris perforating injury. Moreover, he had to accept treatments of phacoemulsification, anterior vitrectomy along with intraocular lens implantation in the sulcus to improve his visual acuity. As acupuncture therapy has been widely performed for various diseases and achieved highly approval, the aim of this report is to remind acupuncturists operating accurately to avoid unnecessary injury during the treatment process, or the cure can also become the weapon.

  17. An analytical model for the determination of resonance frequencies of perforated beams

    International Nuclear Information System (INIS)

    Luschi, Luca; Pieri, Francesco

    2014-01-01

    In this paper, we develop closed expressions for the equivalent bending and shear stiffness of beams with regular square perforations, and apply them to the problem of determining the resonance frequencies of slender, regularly perforated clamped–clamped beams, which are of interest in the development of MEMS resonant devices. We prove that, depending on the perforation size, the Euler–Bernoulli equation or the more complex shear equation needs to be used to obtain accurate values for these frequencies. Extensive finite element method simulations are used to validate the proposed model over the full practical range of possible hole sizes. An experimental verification of the model is also presented. (paper)

  18. Perforator plus flaps: Optimizing results while preserving function and esthesis

    Directory of Open Access Journals (Sweden)

    Mehrotra Sandeep

    2010-01-01

    Full Text Available Background: The tenuous blood supply of traditional flaps for wound cover combined with collateral damage by sacrifice of functional muscle, truncal vessels, or nerves has been the bane of reconstructive procedures. The concept of perforator plus flaps employs dual vascular supply to flaps. By safeguarding perforators along with supply from its base, robust flaps can be raised in diverse situations. This is achieved while limiting collateral damage and preserving nerves, vessels, and functioning muscle with better function and aesthesis. Materials and Methods: The perforator plus concept was applied in seven different clinical situations. Functional muscle and fasciocutaneous flaps were employed in five and adipofascial flaps in two cases, primarily involving lower extremity defects and back. Adipofascial perforator plus flaps were employed to provide cover for tibial fracture in one patients and chronic venous ulcer in another. Results: All flaps survived without any loss and provided long-term stable cover, both over soft tissue and bone. Functional preservation was achieved in all cases where muscle flaps were employed with no clinical evidence of loss of power. There was no sensory loss or significant oedema in or distal to the flap in both cases where neurovascular continuity was preserved during flap elevation. Fracture union and consolidation were satisfactory. One patient had minimal graft loss over fascia which required application of stored grafts with subsequent take. No patient required re-operation. Conclusions: Perforator plus concept is holistic and applicable to most flap types in varied situations. It permits the exercise of many locoregional flap options while limiting collateral functional damage. Aesthetic considerations are also addressed while raising adipofascial flaps because of no appreciable donor defects. With quick operating times and low failure risk, these flaps can be a better substitute to traditional flaps and at

  19. The Use of Magnetic Resonance Imaging in Planning a Pedicled Perforator Flap for Pressure Sores in the Gluteal Region.

    Science.gov (United States)

    Park, Sun-June; Lee, Kyeong-Tae; Jeon, Byung-Joon; Woo, Kyong-Je

    2018-04-01

    Pedicled perforator flaps (PPFs) have been widely used to treat pressure sores in the gluteal region. Selection of a reliable perforator is crucial for successful surgical treatment of pressure sores using PPFs. In this study, we evaluate the role of magnetic resonance imaging (MRI) in planning PPF reconstruction of pressure sores in the gluteal region. A retrospective chart review was performed in patients who had undergone these PPF reconstructions and who had received preoperative MRI. Preoperatively, the extent of infection and necrotic tissue was evaluated using MRI, and a reliable perforator was identified, considering the perforator location in relation to the defect, perforator size, and perforator courses. Intraoperatively, the targeted perforator was marked on the skin at the locations measured on the MRI images, and the marked location was confirmed using intraoperative handheld Doppler. Superior gluteal artery, inferior gluteal artery, or parasacral perforators were used for the PPFs. Surgical outcomes were evaluated. A total of 12 PPFs were performed in 12 patients. Superior gluteal artery perforator flaps were performed in 7 patients, inferior gluteal artery perforator flaps were performed in 3 patients, and parasacral perforator flaps were performed in 2 patients. We could identify a reliable perforator on MRI, and it was found at the predicted locations in all cases. There was only one case of partial flap necrosis. There was no recurrence of the pressure sores during the mean follow-up period of 6.7 months (range = 3-15 months). In selected patients with gluteal pressure sores, MRI is a suitable means for not only providing information about disease extent and comorbidities but also for evaluating perforators for PPF reconstructions.

  20. The Electrical Characteristics of The N-Organic Semiconductor/P-Inorganic Semiconductor Diode

    International Nuclear Information System (INIS)

    Aydin, M. E.

    2008-01-01

    n-organic semiconductor (PEDOT) / p-inorganic semiconductor Si diode was formed by deep coating method. The method has been achieved by coating n-inorganic semiconductor PEDOT on top of p-inorganic semiconductor. The n-organic semiconductor PEDOT/ p-inorganic semiconductor diode demonstrated rectifying behavior by the current-voltage (I-V) curves studied at room temperature. The barrier height , ideality factor values were obtained as of 0.88 eV and 1.95 respectively. The diode showed non-ideal I-V behavior with an ideality factor greater than unity that could be ascribed to the interfacial layer