WorldWideScience

Sample records for perforated pvc pipe

  1. CONTECH(R) A-2000 polyvinyl chloride (PVC) plastic pipe.

    Science.gov (United States)

    2015-03-01

    Determine the effectiveness and long-term durability of the Contech A-2000 PVC pipe : in an irrigation application. This type of pipe may prove to be a viable alternative to : reinforced concrete pipe (RCP).

  2. Properties of lightweight aggregate concrete prepared with PVC granules derived from scraped PVC pipes.

    Science.gov (United States)

    Kou, S C; Lee, G; Poon, C S; Lai, W L

    2009-02-01

    This paper aims to investigate the fresh and hardened properties of lightweight aggregate concretes that are prepared with the use of recycled plastic waste sourced from scraped PVC pipes to replace river sand as fine aggregates. A number of laboratory prepared concrete mixes were tested, in which river sand was partially replaced by PVC plastic waste granules in percentages of 0%, 5%, 15%, 30% and 45% by volume. Two major findings are identified. The positive side shows that the concrete prepared with a partial replacement by PVC was lighter (lower density), was more ductile (greater Poisson's ratios and reduced modulus of elasticity), and had lower drying shrinkage and higher resistance to chloride ion penetration. The negative side reveals that the workability, compressive strength and tensile splitting strength of the concretes were reduced. The results gathered would form a part of useful information for recycling PVC plastic waste in lightweight concrete mixes.

  3. Residual lifetime assessment of uPVC gas pipes

    NARCIS (Netherlands)

    Visser, H.A.

    2010-01-01

    The Dutch gas distribution network consists of about 20% (22,500 km) of unplasticised poly(vinyl chloride) (uPVC) pipes, most of which have been installed from the mid-sixties up to the mid-seventies of the previous century and have been in service ever since. In the next decade the specified

  4. Volatile organic components migrating from plastic pipes (HDPE, PEX and PVC) into drinking water.

    Science.gov (United States)

    Skjevrak, Ingun; Due, Anne; Gjerstad, Karl Olav; Herikstad, Hallgeir

    2003-04-01

    High-density polyethylene pipes (HDPE), crossbonded polyethylene pipes (PEX) and polyvinyl chloride (PVC) pipes for drinking water were tested with respect to migration of volatile organic components (VOC) to water. The odour of water in contact with plastic pipes was assessed according to the quantitative threshold odour number (TON) concept. A major migrating component from HDPE pipes was 2,4-di-tert-butyl-phenol (2,4-DTBP) which is a known degradation product from antioxidants such as Irgafos 168(R). In addition, a range of esters, aldehydes, ketones, aromatic hydrocarbons and terpenoids were identified as migration products from HDPE pipes. Water in contact with HDPE pipes was assessed with respect to TON, and values > or =4 were determined for five out of seven brands of HDPE pipes. The total amount of VOC released to water during three successive test periods were fairly constant for the HDPE pipes. Corresponding migration tests carried out for PEX pipes showed that VOC migrated in significant amounts into the test water, and TON >/=5 of the test water were observed in all tests. Several of the migrated VOC were not identified. Oxygenates predominated the identified VOC in the test water from PEX pipes. Migration tests of PVC pipes revealed few volatile migrants in the test samples and no significant odour of the test water.

  5. Sensory aspects and water quality impacts of chlorinated and chloraminated drinking water in contact with HDPE and cPVC pipe.

    Science.gov (United States)

    Heim, Timothy H; Dietrich, Andrea M

    2007-02-01

    Pipes constructed with high-density polyethylene (HDPE) or chlorinated polyvinyl chloride (cPVC) are commonly used in drinking water distribution systems and premise plumbing. In this comprehensive investigation, the effects on odor, organic chemical release, trihalomethane (THM) formation, free chlorine demand and monochloramine demand were determined for water exposed to HDPE and cPVC pipes. The study was conducted in accordance with the Utility Quick Test (UQT), a migration/leaching protocol for analysis of materials in contact with drinking water. The sensory panel consistently attributed a weak to moderate intensity of a "waxy/plastic/citrus" odor to the water from the HDPE pipes but not the cPVC-contacted water samples. The odor intensity generated by the HDPE pipe remained relatively constant for multiple water flushes, and the odor descriptors were affected by disinfectant type. Water samples stored in both types of pipe showed a significant increase in the leaching of organic compounds when compared to glass controls, with HDPE producing 0.14 microgTOC/cm(2) pipe surface, which was significantly greater than the TOC release from cPVC. Water stored in both types of pipe showed disinfectant demands of 0.1-0.9 microg disinfectant/cm(2) pipe surface, with HDPE exerting more demand than cPVC. No THMs were detected in chlorinated water exposed to the pipes. The results demonstrate the impact that synthetic plumbing materials can have on sensory and chemical water quality, as well as the significant variations in drinking water quality generated from different materials.

  6. Fittings of unplasticized polyvinyl chloride (PVC-U), chlorinated polyvinyl chloride (PVC-C) or acrylonitrile/butadiene/styrene (ABS) with plain sockets for pipes under pressure - Dimensions of sockets - Metric series

    CERN Document Server

    International Organization for Standardization. Geneva

    1985-01-01

    Fittings of unplasticized polyvinyl chloride (PVC-U), chlorinated polyvinyl chloride (PVC-C) or acrylonitrile/butadiene/styrene (ABS) with plain sockets for pipes under pressure - Dimensions of sockets - Metric series

  7. Review of the use of rigid and high-impact PVC pipes in natural gas distribution systems in the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Mutter, F; Benjamin, P

    1974-08-01

    Because of a number of instances of stress corrosion cracking or crazing occurring in PVC pipes used in Dutch gas distribution systems, VEG-GASINSTITUUT began an intensive investigation of rigid PVC pipes and high-impact pipes in distribution use under various conditions and with varying service lives. The work led to an investigation of laboratory testing techniques in which the stress-cracking phenomenon found in practice could be duplicated under controllable conditions. Pipes of various materials were examined for their resistance to stress cracking, then this resistance was compared with other long- and short-term physical properties of the material.

  8. Evaluation of the influence of water and oil derivatives absorption on PVC pipes

    International Nuclear Information System (INIS)

    Carpio, D.C.F. del; D'Almeida, J.R.M.

    2010-01-01

    PVC is the only polymer of large consume that is not totally obtained from petroleum, since it contains 57% of chlorine. As chlorine containing materials are resistant to bacteria rich environments, such as buried pipes, PVC is being used for fluid transportation, principally water, but it can also be considered as an alternative material for the transportation of other fluids. This work analyzes the aging behavior of PVC exposed to water, ethanol and diesel oil, using TGA, DSC, FT-IR and DR-X techniques. The results showed that the chemical structure of PVC is not affected by exposure to water and ethanol. For these fluids a dipolar interaction could be occurring, increasing at the beginning of the absorption process, the polymer thermal stability. The diesel oil caused plasticization, with reduction of the Tg since the beginning of the aging process. (author)

  9. Plastics piping systems for industrial applications : acrylonitrile-butadiene- styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) : specifications for components and the system : metric series

    CERN Document Server

    International Organization for Standardization. Geneva

    2003-01-01

    Plastics piping systems for industrial applications : acrylonitrile-butadiene- styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) : specifications for components and the system : metric series

  10. Understanding and coming through PVC-tape-induced stress corrosion cracking in PWR piping system

    International Nuclear Information System (INIS)

    Shibayama, Motoaki; Shigemoto, Naoya; Noguchi, Shinji; Hirano, Shin-ichi; Takagi, Toshimitsu

    2003-01-01

    In October 2000, the 24 years old Ikata-1 PWR-type nuclear power plant suffered cracking in pipes of special two lines, where poly vinyl chloride (PVC) tape had been placed and had become baked over time. The existence of residual stress over 100 MPa in the pipes, a bit of chlorine and a feather like-pattern on the crack faces suggested the event was one of stress corrosion cracking. Residual chlorine on the pipes of special two lines was estimated to be 1100 mg/m 2 . A four points bending stress test was performed on the steel plates with the baked on PVC tape in humid air at 80degC. Taking the actual temperature, stress and chlorine on the pipes of the special two lines into consideration, cracking times were estimated to be 12 years and 15 years respectively, which were close to the actual cracking time of 24 years. The authors calculated damage to pipes with fluids of various temperature and duration, and graphed damage contour with a fluid temperature ordinate and a flow duration abscissa. The fluid conditions of major pipes at the Ikata-1 nuclear power plant, which had not received the full inspection, were positioned on so low area on the damage contour that the plant was estimated to be safe for the coming forty years. (author)

  11. Plastics piping systems for industrial applications – Acrylonitrile-butadiene-styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) – Specifications for components and the system – Metric series

    CERN Document Server

    Deutsches Institut für Normung. Berlin

    2003-01-01

    Plastics piping systems for industrial applications – Acrylonitrile-butadiene-styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) – Specifications for components and the system – Metric series

  12. AN INVESTIGATION OF THE IMPACT OF IMPURITIES ON THE MECHANICAL PROPERTIES OF RECYCLED PVC EXTRUSION PIPES

    OpenAIRE

    Adamu Alhaji Umar; Raji Olalere Fatai

    2007-01-01

    This work studied the effect of using recycled scraps in the production of rigid PVC extrusion pipe. Different formulations with varied percentages of scraps were extruded and various tests carried out on the sample specimen to determine their corresponding mechanical properties. It was finally discovered that among the two sources of scraps, the in-house scraps contained less impurities and blending about 10% of it with virgin PVC material in the production gave improved mechanical propertie...

  13. PVC pipes in gas distribution: still going strong!

    NARCIS (Netherlands)

    Hermkens, Rene; Wolters, Mannes; Weller, Jeroen; Visser, Roy; Davidovski, Z.; Belloir, P.; Fumire, J.

    2008-01-01

    In the Netherlands (impact-modified) PVC is the preferred material for low-pressure (30 and 100 mbar) gas distribution systems. More than 50% of the total length (about 122,000 km) of this system is rigid PVC or impact-modified PVC. The installation of rigid PVC (uPVC) pipelines started about 50

  14. Mechanical, Spectroscopic and Micro-structural Characterization of Banana Particulate Reinforced PVC Composite as Piping Material

    Directory of Open Access Journals (Sweden)

    B. Dan-asabe

    2016-06-01

    Full Text Available A banana particulate reinforced polyvinyl chloride (PVC composite was developed with considerabley low cost materials having an overall light-weight and good mechanical properties for potential application as piping material. The specimen composite material was produced with the banana (stem particulate as reinforcement using compression molding. Results showed that density and elastic Modulus of the composite decreases and increases respectively with increasing weight fraction of the particulate reinforcement. The tensile strength increased to a maximum of 42 MPa and then decreased steadily. The composition with optimum mechanical property (42 MPa was determined at 8, 62 and 30 % formulation of banana stem particulates (reinforcement, PVC (matrix and Kankara clay (filler respectively with corresponding percentage water absorption of 0.79 %, Young’s Modulus of 1.3 GPa, flexural strength of 92 MPa and density of 1.24 g/cm3. Fourier Transform Infrared (FTIR analysis of the constituents showed identical bands within the range 4000–1000 cm-1 with renown research work. Scanning Electron Microscopy (SEM result showed fairly uniform distribution of constituents’ phases. X-Ray Fluorescence (XRF confirms the X-ray diffraction (XRD result of the presence of minerals of kaolinite, quartz, rutile and illite in the kaolin clay. Comparison with conventional piping materials showed the composite offered a price savings per meter length of 84 % and 25 % when compared with carbon steel and PVC material.

  15. Evaluation of the influence of water and oil derivatives absorption on PVC pipes; Avaliacao da influencia da absorcao de agua e de derivados de petroleo em tubulacoes de PVC

    Energy Technology Data Exchange (ETDEWEB)

    Carpio, D.C.F. del; D' Almeida, J.R.M., E-mail: dalmeida@puc-rio.b [Pontificia Univ. Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil). Dept. de Engenharia de Materiais

    2010-07-01

    PVC is the only polymer of large consume that is not totally obtained from petroleum, since it contains 57% of chlorine. As chlorine containing materials are resistant to bacteria rich environments, such as buried pipes, PVC is being used for fluid transportation, principally water, but it can also be considered as an alternative material for the transportation of other fluids. This work analyzes the aging behavior of PVC exposed to water, ethanol and diesel oil, using TGA, DSC, FT-IR and DR-X techniques. The results showed that the chemical structure of PVC is not affected by exposure to water and ethanol. For these fluids a dipolar interaction could be occurring, increasing at the beginning of the absorption process, the polymer thermal stability. The diesel oil caused plasticization, with reduction of the Tg since the beginning of the aging process. (author)

  16. Carneiro hidráulico com tubulação de alimentação em aço galvanizado e em PVC Hydraulic ram pump perfomance with PVC and steel pipes

    Directory of Open Access Journals (Sweden)

    Caroline Abate

    2002-03-01

    Full Text Available A recente crise da energia convencional tem ocasionado a exploração de fontes alternativas de energia. O bombeamento de água utilizando carneiro hidráulico é amplamente empregado em propriedades onde a energia elétrica é escassa ou inexistente. Procurando dar subsídios técnicos para a utilização do PVC nos sistemas de alimentação de um carneiro hidráulico, foi desenvolvido um experimento com objetivo de avaliar o desempenho de um carneiro hidráulico quando alimentado por uma tubulação de PVC e outra de aço galvanizado, sob três alturas de queda (2,1, 3,8 e 4,7 m. Foi utilizada a equação de D'Aubussion's para a avaliação do rendimento, calculado a partir de leituras de altura de recalque, vazão de escape, vazão de recalque e altura de alimentação. Pode-se conseguir o máximo rendimento com o carneiro hidráulico utilizando-se de tubulação de PVC com até 4,2 m de desnível; além desse valor a tubulação de aço galvanizado é mais eficiente.The recent conventional energy crisis is leading to the exploration of alternative energy sources. The pumping of water using ram pumps is widely used in farms where electric energy is scarce or inexistent. This experiment was carried out to evaluate the performance of an hydraulic ram pump utilizing two kinds of supply pipes (PVC and steel using three different supply heads (2.1, 3.8 and 4.7. Delivery head, delivery discharge, waste discharge and supply head were utilized to calculate the yield of the hydraulic ram by the equation of D'Aubussion. The maximum yield of the hydraulic ram was obtained for the PVC pipe for the 4.2 m head; for heads higher than 4.2 m the steel pipe was more efficient.

  17. Heat Conductivity Resistance of Concrete Wall Panel by Water Flowing in Different Orientations of Internal PVC pipe

    Science.gov (United States)

    Umi, N. N.; Norazman, M. N.; Daud, N. M.; Yusof, M. A.; Yahya, M. A.; Othman, M.

    2018-04-01

    Green building technology and sustainability development is current focus in the world nowadays. In Malaysia and most tropical countries the maximum temperature recorded typically at 35°C. Air-conditioning system has become a necessity in occupied buildings, thereby increasing the cost of electric consumption. The aim of this study is to find out the solution in minimizing heat transfer from the external environment and intentions towards going green. In this study, the experimental work includes testing three types of concrete wall panels. The main heat intervention material in this research is 2 inch diameter Polyvinyl Chloride (PVC) pipe embedded at the center of the concrete wall panel, while the EPS foam beads were added to the cement content in the concrete mix forming the outer layer of the wall panel. Water from the rainwater harvesting system is regulated in the PVC pipe to intervene with the heat conductivity through the wall panel. Results from the experimental works show that the internal surface temperature of these heat resistance wall panels is to 3□C lower than control wall panel from plain interlocking bricks.

  18. Application of water flowing PVC pipe and EPS foam bead as insulation for wall panel

    Science.gov (United States)

    Ali, Umi Nadiah; Nor, Norazman Mohamad; Yusuf, Mohammed Alias; Othman, Maidiana; Yahya, Muhamad Azani

    2018-02-01

    Malaysia located in tropical climate which have a typical temperature range between 21 °C to 36 °C. Due to this, air-conditioning system for buildings become a necessity to provide comfort to occupants. In order to reduce the energy consumption of the air-conditioning system, the transmission of heat from outdoor to indoor space should be kept as minimum as possible. This article discuss about a technology to resist heat transfer through concrete wall panel using a hybrid method. In this research, PVC pipe was embedded at the center of concrete wall panel while the EPS foam beads were added about 1% of the cement content in the concrete mix forming the outer layer of the wall panel. Water is regulated in the PVC pipe from the rainwater harvesting system. The aim of this study is to minimize heat transfer from the external environment into the building. Internal building temperature which indicated in BS EN ISO 7730 or ASHRAE Standard 55 where the comfort indoor thermal is below 25°C during the daytime. Study observed that the internal surface temperature of heat resistance wall panel is up to 3°C lower than control wall panel. Therefore, we can conclude that application of heat resistance wall panel can lead to lower interior building temperature.

  19. Construction and demolition waste as a source of PVC for recycling.

    Science.gov (United States)

    Prestes, Sabrina Moretto Darbello; Mancini, Sandro Donnini; Rodolfo, Antonio; Keiroglo, Raquel Carramillo

    2012-02-01

    Construction and demolition waste can contain considerable amounts of polyvinyl chloride (PVC). This paper describes a study of the recycling of PVC pipes collected from such waste materials. In a sorting facility for the specific disposal of construction and demolition waste, PVC was found to represent one-third of the plastics separated by workers. Pipes were sorted carefully to preclude any possible contamination by poly(ethylene terephthalate) (PET) found in the waste. The material was ground into two distinct particle sizes (final mesh of 12.7 and 8 mm), washed, dried and recycled. The average formulation of the pipes was determined based on ash content tests and used in the fabrication of a similar compound made mainly of virgin PVC. Samples of recycled pipes and of compound based on virgin material were subjected to tensile and impact tests and provided very similar results. These results are a good indication of the application potential of the recycled material and of the fact that longer grinding to obtain finer particles is not necessarily beneficial.

  20. Investigation on the Acoustic Absorption of Flexible Micro-Perforated Panel with Ultra-Micro Perforations

    Science.gov (United States)

    Li, Guoxin; Tang, Xiaoning; Zhang, Xiaoxiao; Qian, Y. J.; Kong, Deyi

    2017-11-01

    Flexible micro-perforated panel has unique advantages in noise reduction due to its good flexibility compared with traditional rigid micro-perforated panel. In this paper, flexible micro-perforated panel was prepared by computer numerical control (CNC) milling machine. Three kinds of plastics including polyvinylchloride (PVC), polyethylene terephthalate (PET), and polyimide (PI) were taken as the matrix materials to prepare flexible micro-perforated panel. It has been found that flexible micro-perforated panel made of PET possessing good porosity and proper density, elastic modulus and poisson ratio exhibited the best acoustic absorption properties. The effects of various structural parameters including perforation diameter, perforation ratio, thickness and air gap have also been investigated, which would be helpful to the optimization of acoustic absorption properties.

  1. Detection of active noise control on the standard motorcycle exhaust Supra X 125 D using PVC pipe technique form Y

    Science.gov (United States)

    Isranuri, I.; Alfisyahrin; Nasution, A. R.

    2018-02-01

    This detection aims to obtain noise reduction on the supra X 125D motorcycle exhaust by using the Active Noise Control Method. The technique is done using a Y-shaped PVC pipe to be bolted on the exhaust, which then branch Y PVC is placed loudspeaker with impermeable conditions. The function of this loudspeaker is as a secondary noise to counter the primary noise of the sound of exhaust motorcycle Supra X 125D. The sound generator in this study is the ISD 4004 module, which serves to generate noise to counter the source noise. How this ISD 4004 module works is by recording source noise then recording the source noise and then reversed the phase 180° by phase reversing circuit. So that, the noise generated by the sound generator will hit the source noise and encounter or such as addition of two different phase of sound will result in noise reduction when detected at the end of the Y-shaped PVC pipe. Inverted phase reversed using feed-back resistor 1 kΩ and 2 kΩ input resistors, 16V capacitor 2500μf and as amplifier using ICL 7660 and TL 702 CP. Test results on the highest 1000 rpm rotation engine speed on the Z axis of 2 dB, and at the highest 2000 rpm rotation engine speed also occurs on the Z axis of 1.5 dB.

  2. Polarizing PVC — A Discrepant Event

    Science.gov (United States)

    Headly, David; Karabatek, Mohamed

    2016-01-01

    Each year when teaching polarization phenomena and the Triboelectric Series in a unit on electrostatics, I would balance some rods (2-3 ft in length) made from wood, aluminum, PVC, and Plexiglas on an inverted watch glass and demonstrate to the class how a party balloon rubbed with fake rabbit fur (charging the balloon negative) would always attract the uncharged rods, causing them to rotate towards the balloon (see Fig. 1). The fact that a charged object always attracts a neutral object due to the induced dipole in the latter is a great way to test if something is in fact charged. Surprisingly, the PVC pipe would usually, but not always, repel the charged balloon and rotate away! Repulsion means that neither of the objects are electrically neutral. In a separate test, after rubbing together a Plexiglas rod with a polyethylene grocery bag (making the rod positively charged and the bag negatively charged), the PVC usually attracts the rod. With the help of a student as part of his senior project, I finally decided to investigate further the source of the negative charge that exists on PVC. Specifically, is it nothing more than static charge that builds up on the pipe from unavoidable contact with its surroundings, or is it somehow intrinsic to the manufacturing process?

  3. A numerical study on the conjugate natural convection in a circular pipe containing water

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Myoung-Young; Choi, Hyoung-Gwon [Seoul National University of Science & Technology, Seoul (Korea, Republic of)

    2017-07-15

    In this paper, the effect of material property of pipe on the conjugate natural convection in a circular pipe containing water was investigated by solving the unsteady incompressible Navier-Stokes equations coupled with energy equations of the water and pipe. Natural convection and conduction of water inside the pipe was coupled with the conduction of the pipe whose bottom was subject to uniform heat source. From the present grid resolution and time-step independent solutions, it has been confirmed that the water temperature inside a PVC pipe was higher than that inside a steel pipe due to the smaller heat capacity of PVC and that the streamline patterns of the two cases were found to be opposite because the thermal diffusivity of steel (PVC) is larger (smaller) than that of water such that steel (PVC) pipe is heated faster (slower) than water. Furthermore, a quantitative comparison of heat flux to water was performed by examining the distributions of the heat flux along the inside walls of steel/PVC. The average temperature of water inside steel was found to be higher than that inside PVC at the initial stage of heating. On the other hand, PVC provided a larger heat flux to water when it reached a steady value.

  4. Excellent impact performance of PVC pipeline materials in gas distribution networks after many years of service (CD-rom)

    NARCIS (Netherlands)

    Visser, Roy; Hermkens, R.M.J.; Wolters, Mannes; Weller, J.; Warnet, Laurent; Beckervordersandforth, C.; Verberg, G.H.B.; Kramer, M.

    2008-01-01

    It has been about fifty years ago since the first unplasticized poly(vinyl chloride) (uPVC) pipes were installed for use in gas distribution purposes. Currently, about 22,500 km of uPVC is still in use in the Dutch gas distribution network. The pipes were originally designed for a lifetime of 50

  5. A physical probabilistic model to predict failure rates in buried PVC pipelines

    International Nuclear Information System (INIS)

    Davis, P.; Burn, S.; Moglia, M.; Gould, S.

    2007-01-01

    For older water pipeline materials such as cast iron and asbestos cement, future pipe failure rates can be extrapolated from large volumes of existing historical failure data held by water utilities. However, for newer pipeline materials such as polyvinyl chloride (PVC), only limited failure data exists and confident forecasts of future pipe failures cannot be made from historical data alone. To solve this problem, this paper presents a physical probabilistic model, which has been developed to estimate failure rates in buried PVC pipelines as they age. The model assumes that under in-service operating conditions, crack initiation can occur from inherent defects located in the pipe wall. Linear elastic fracture mechanics theory is used to predict the time to brittle fracture for pipes with internal defects subjected to combined internal pressure and soil deflection loading together with through-wall residual stress. To include uncertainty in the failure process, inherent defect size is treated as a stochastic variable, and modelled with an appropriate probability distribution. Microscopic examination of fracture surfaces from field failures in Australian PVC pipes suggests that the 2-parameter Weibull distribution can be applied. Monte Carlo simulation is then used to estimate lifetime probability distributions for pipes with internal defects, subjected to typical operating conditions. As with inherent defect size, the 2-parameter Weibull distribution is shown to be appropriate to model uncertainty in predicted pipe lifetime. The Weibull hazard function for pipe lifetime is then used to estimate the expected failure rate (per pipe length/per year) as a function of pipe age. To validate the model, predicted failure rates are compared to aggregated failure data from 17 UK water utilities obtained from the United Kingdom Water Industry Research (UKWIR) National Mains Failure Database. In the absence of actual operating pressure data in the UKWIR database, typical

  6. Development of a continuous flow model system for studies of biofilm formation on polymers and its application on PVC-C and PVC-P

    DEFF Research Database (Denmark)

    Corfitzen, Charlotte B.; Albrechtsen, Hans-Jørgen

    could be harvested from three different combinations of flow velocity and residence time. Biofilm formation was followed by ATP analysis on test material (chlorinated polyvinylchloride, PVC-C), negative control (stainless steel) and positive control (plasticized polyvinylchloride, PVC-P) incubated......-C, while most of the very deviating values for PVC-P were between 2-13,000 pg ATP/cm2. During 43 weeks of operation of the continuous flow model systems the biofilm formation increased on all three materials, with biofilm formation on PVC-C at the same level as on the negative steel control (values of 75...... system. In this study, a continuous flow model system was developed, for investigating biofilm formation on polymers, simulating conditions in the distribution system. Commercially available pipes were used for exchangeable test pieces, which allowed for testing over prolonged time periods. Test pieces...

  7. Co-occurrence of invasive Cuban Treefrogs and native treefrogs in PVC pipe refugia

    Science.gov (United States)

    Elston, Laura M.; Waddle, J. Hardin; Rice, Kenneth G.; Percival, H. Franklin

    2013-01-01

    The Cuban Treefrog (Osteopilus septentrionalis) was first introduced to Florida at Key West. Since this introduction, Cuban Treefrogs have spread to Miami and are now established throughout most of peninsular Florida. Cuban Treefrogs can become very abundant in areas they colonize. Several reasons contribute to their success, including a generalist diet, high fecundity and the ability to reproduce year-round, and use of disturbed or human-modified habitats. Scientists and managers are concerned that Cuban Treefrogs may contribute to the decline of native treefrogs. Cuban Treefrogs may exclude native treefrogs through both competition and predation. Because the evidence from our study and others suggests that Green and Squirrel Treefrogs do not alter their behavior to avoid Cuban Treefrogs, there is cause for concern that sampling with PVC pipes may increase the vulnerability of the native species to predation. This possibility needs further research, including whether other species of native treefrogs sympatric to where Cuban Treefrogs have invaded are also naïve to the possible threat posed by these frogs, and also if native treefrogs eventually learn to avoid Cuban Treefrogs.

  8. Investigation of fatigue and mechanical properties of the pipe grade poly(vinyl chloride using recycled scraps

    Directory of Open Access Journals (Sweden)

    J-M. Lee

    2015-04-01

    Full Text Available In this paper, the effect of using pre-consumer PVC scraps on static and long-term mechanical properties is studied. The degradation characteristics of mixing virgin PVC with crushed pre-consumer and PVC pipe scraps are analyzed using various tools including Gel Permeation Chromatography (GPC, Thermogravimetric Analysis (TGA, X-ray fluorescence (XRF and Fourier Transform Infrared (FTIR spectroscopy. The variation of static mechanical properties as a function of adding pre-consumer PVC pipe scraps is investigated using the degradation analyses of recycled PVC scraps. In addition, fatigue tests are executed to evaluate the long-term durability of blending virgin PVC and recycled PVC scraps, and the fracture surface is investigated in detail to reveal the variation of the fracture mechanisms.

  9. Reseeding of mussels on denuded rocky shores: preliminary studies ...

    African Journals Online (AJOL)

    A method is developed to establish clumps of mussels Perna perna in denuded areas on high-energy rocky shores on the south-east coast of South Africa. A total of 20 small (20–30 mm total length) mussels is placed under a 30 cm half-section of perforated PVC drainage pipe bolted to the rock surface. The pipe is left in ...

  10. Passive aeration composting of chicken litter: effects of aeration pipe orientation and perforation size on losses of compost elements.

    Science.gov (United States)

    Ogunwande, Gbolabo A; Osunade, James A

    2011-01-01

    A passive aeration composting study was undertaken to investigate the effects of aeration pipe orientation (PO) and perforation size (PS) on some physico-chemical properties of chicken litter (chicken manure + sawdust) during composting. The experimental set up was a two-factor completely randomised block design with two pipe orientations: horizontal (Ho) and vertical (Ve), and three perforation sizes: 15, 25 and 35 mm diameter. The properties monitored during composting were pile temperature, moisture content (MC), pH, electrical conductivity (EC), total carbon (C(T)), total nitrogen (N(T)) and total phosphorus (P(T)). Moisture level in the piles was periodically replenished to 60% for efficient microbial activities. The results of the study showed that optimum composting conditions (thermophilic temperatures and sanitation requirements) were attained in all the piles. During composting, both PO and PS significantly affected pile temperature, moisture level, pH, C(T) loss and P(T) gain. EC was only affected by PO while N(T) was affected by PS. Neither PO nor PS had a significant effect on the C:N ratio. A vertical pipe was effective for uniform air distribution, hence, uniform composting rate within the composting pile. The final values showed that PO of Ve and PS of 35 mm diameter resulted in the least loss in N(T). The PO of Ho was as effective as Ve in the conservation of C(T) and P(T). Similarly, the three PSs were equally effective in the conservation of C(T) and P(T). In conclusion, the combined effects of PO and PS showed that treatments Ve35 and Ve15 were the most effective in minimizing N(T) loss. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. Quality control in the recycling stream of PVC from window frames by hyperspectral imaging

    Science.gov (United States)

    Luciani, Valentina; Serranti, Silvia; Bonifazi, Giuseppe; Di Maio, Francesco; Rem, Peter

    2013-05-01

    Polyvinyl chloride (PVC) is one of the most commonly used thermoplastic materials in respect to the worldwide polymer consumption. PVC is mainly used in the building and construction sector, products such as pipes, window frames, cable insulation, floors, coverings, roofing sheets, etc. are realised utilising this material. In recent years, the problem of PVC waste disposal gained increasing importance in the public discussion. The quantity of used PVC items entering the waste stream is gradually increased as progressively greater numbers of PVC products approach to the end of their useful economic lives. The quality of the recycled PVC depends on the characteristics of the recycling process and the quality of the input waste. Not all PVC-containing waste streams have the same economic value. A transparent relation between value and composition is required to decide if the recycling process is cost effective for a particular waste stream. An objective and reliable quality control technique is needed in the recycling industry for the monitoring of both recycled flow streams and final products in the plant. In this work hyperspectral imaging technique in the near infrared (NIR) range (1000-1700 nm) was applied to identify unwanted plastic contaminants and rubber present in PVC coming from windows frame waste in order to assess a quality control procedure during its recycling process. Results showed as PVC, PE and rubber can be identified adopting the NIR-HSI approach.

  12. Experimental and numerical analysis of water hammer in a large-scale PVC pipeline apparatus

    NARCIS (Netherlands)

    Bergant, A.; Hou, Q.; Keramat, A.; Tijsseling, A.S.; Gajic, A.; Benisek, M.; Nedeljkovic, M.

    2011-01-01

    This paper investigates the effects of the pipe-wall viscoelasticity on water-hammer pressures. A large-scale pipeline apparatus made of polyvinyl chloride (PVC) at Deltares, Delft, The Netherlands, has been used to carry out waterhammer experiments. Tests have been conducted in a

  13. Investigation of organic matter migrating from polymeric pipes into drinking water under different flow manners.

    Science.gov (United States)

    Zhang, Ling; Liu, Shuming; Liu, Wenjun

    2014-02-01

    Polymeric pipes, such as unplasticized polyvinyl chloride (uPVC) pipes, polypropylene random (PPR) pipes and polyethylene (PE) pipes are increasingly used for drinking water distribution lines. Plastic pipes may include some additives like metallic stabilizers and other antioxidants for the protection of the material during its production and use. Thus, some compounds can be released from those plastic pipes and cast a shadow on drinking water quality. This work develops a new procedure to investigate three types of polymer pipes (uPVC, PE and PPR) with respect to the migration of total organic carbon (TOC) into drinking water. The migration test was carried out in stagnant conditions with two types of migration processes, a continuous migration process and a successive migration process. These two types of migration processes are specially designed to mimic the conditions of different flow manners in drinking water pipelines, i.e., the situation of continuous stagnation with long hydraulic retention times and normal flow status with regular water renewing in drinking water networks. The experimental results showed that TOC release differed significantly with different plastic materials and under different flow manners. The order of materials with respect to the total amount of TOC migrating into drinking water was observed as PE > PPR > uPVC under both successive and continuous migration conditions. A higher amount of organic migration from PE and PPR pipes was likely to occur due to more organic antioxidants being used in pipe production. The results from the successive migration tests indicated the trend of the migration intensity of different pipe materials over time, while the results obtained from the continuous migration tests implied that under long stagnant conditions, the drinking water quality could deteriorate quickly with the consistent migration of organic compounds and the dramatic consumption of chlorine to a very low level. Higher amounts of TOC

  14. A reciclagem de PVC no Brasil Recycling of PVC Brazil

    Directory of Open Access Journals (Sweden)

    Ana Magda Piva

    1999-12-01

    Full Text Available Esta pesquisa discute as possibilidades práticas da reciclagem de PVC. Na reciclagem de polímeros, a do PVC representa uma importante parcela. PVC é um polímero que é usado em uma ampla faixa de produtos: filmes, fios, cabos, em compostos para uma variedade de formas. A reciclagem é uma técnica vantajosa, capaz de reproduzir as propriedades do polímero original, no polímero reciclado e isto em condições razoavelmente econômicas. A tecnologia brasileira, em relação a produtos reciclados, apresenta algumas diferenças da reciclagem tradicional. Métodos alternativos de reciclagens são necessários se os processos não desvalorizam os resultados finais.This research discuss the practical possibilities of recycling PVC. PVC, plays an important part in the recycleability of polymers; PVC is a polymer which is used in a very wide range of products -films, wire, cabes, in compounds for a variety of forms. Recycling is only worthwile, one is able to reproduce the original polymer properties in the polymer being recycled, and this under reasonable economics conditions. The brasilian technology that produces recycled products is a little different from the tradicional recycling. Therefore alternative methods to recycle are needed if recycling is not to devalue the end results.

  15. Electrospinning of PVC with natural rubber

    Science.gov (United States)

    Othman, Muhammad Hariz; Mohamed, Mahathir; Abdullah, Ibrahim

    2013-11-01

    Polyvinyl chloride (PVC) was mixed with natural rubbers which are liquid natural rubber (LNR), liquid epoxidised natural rubber (LENR) and liquid epoxidised natural rubber acrylate (LENRA) for a preparation of a fine non-woven fiber's mat. PVC and each natural rubbers(PVC:LENR, PVC:LNR and PVC:LENRA) were mixed based on ratio of 70:30. Electrospinning method was used to prepare the fiber. The results show that the spinnable concentration of PVC/ natural rubber/THF solution is 16 wt%. The morphology, diameter, structure and degradation temperature of electrospun fibers were investigated by scanning electron microscopy (SEM) and thermogravimetric analysis (TGA). SEM photos showed that the morphology and diameter of the fibers were mainly affected by the addition of natural rubber. TGA results suggested that PVC electrospun fiber has higher degradation temperature than those electrospun fibers that contain natural rubber.

  16. Electrospinning of PVC with natural rubber

    International Nuclear Information System (INIS)

    Othman, Muhammad Hariz; Abdullah, Ibrahim; Mohamed, Mahathir

    2013-01-01

    Polyvinyl chloride (PVC) was mixed with natural rubbers which are liquid natural rubber (LNR), liquid epoxidised natural rubber (LENR) and liquid epoxidised natural rubber acrylate (LENRA) for a preparation of a fine non-woven fiber’s mat. PVC and each natural rubbers(PVC:LENR, PVC:LNR and PVC:LENRA) were mixed based on ratio of 70:30. Electrospinning method was used to prepare the fiber. The results show that the spinnable concentration of PVC/ natural rubber/THF solution is 16 wt%. The morphology, diameter, structure and degradation temperature of electrospun fibers were investigated by scanning electron microscopy (SEM) and thermogravimetric analysis (TGA). SEM photos showed that the morphology and diameter of the fibers were mainly affected by the addition of natural rubber. TGA results suggested that PVC electrospun fiber has higher degradation temperature than those electrospun fibers that contain natural rubber

  17. Electrospinning of PVC with natural rubber

    Energy Technology Data Exchange (ETDEWEB)

    Othman, Muhammad Hariz; Abdullah, Ibrahim [Department of Chemistry, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia); Mohamed, Mahathir [Radiation Processing Technology Division (BTS), Malaysian Nuclear Agency, Bangi, 43000, Kajang (Malaysia)

    2013-11-27

    Polyvinyl chloride (PVC) was mixed with natural rubbers which are liquid natural rubber (LNR), liquid epoxidised natural rubber (LENR) and liquid epoxidised natural rubber acrylate (LENRA) for a preparation of a fine non-woven fiber’s mat. PVC and each natural rubbers(PVC:LENR, PVC:LNR and PVC:LENRA) were mixed based on ratio of 70:30. Electrospinning method was used to prepare the fiber. The results show that the spinnable concentration of PVC/ natural rubber/THF solution is 16 wt%. The morphology, diameter, structure and degradation temperature of electrospun fibers were investigated by scanning electron microscopy (SEM) and thermogravimetric analysis (TGA). SEM photos showed that the morphology and diameter of the fibers were mainly affected by the addition of natural rubber. TGA results suggested that PVC electrospun fiber has higher degradation temperature than those electrospun fibers that contain natural rubber.

  18. Plastics pipe couplings

    International Nuclear Information System (INIS)

    Glover, J.B.

    1980-07-01

    A method is described of making a pipe coupling of the type comprising a plastics socket and a resilient annular sealing member secured in the mouth thereof, in which the material of at least one component of the coupling is subjected to irradiation with high energy radiation whereby the material is caused to undergo cross-linking. As examples, the coupling may comprise a polyethylene or plasticised PVC socket the material of which is subjected to irradiation, and the sealing member may be moulded from a thermoplastic elastomer which is subjected to irradiation. (U.K.)

  19. Estudo do uso de plastificantes de fontes renovável em composições de PVC Study of the use of plasticizer from renewable sources in PVC compositions

    Directory of Open Access Journals (Sweden)

    Emerson Madaleno

    2009-01-01

    Full Text Available Polímeros sintéticos são largamente utilizados em diversos produtos devido às suas propriedades físicas, químicas e facilidade de transformação. O poli(cloreto de vinila, conhecido como PVC, é um dos polímeros mais versáteis desenvolvidos pelo homem, de grande utilidade para a sociedade moderna. Suas aplicações incluem: janelas, calhas de chuva, revestimentos de paredes, portas, papel de parede, mangueiras, brinquedos, calçados, bolsas de sangue e tubos para condução de água. Em todas estas aplicações são utilizados aditivos junto à resina de PVC, sendo que um dos aditivos mais utilizados é o plastificante. Este estudo apresenta a análise comparativa de formulações flexíveis de PVC, baseada em dois plastificantes de origem renovável (óleo vegetal modificado - OVM e óleo vegetal modificado e epoxidado - OVME, e também dois plastificantes petroquímicos convencionais, di(2-etilhexil ftalato - (DEHP ou DOP e di(2-etilhexil adipato - (DEHA ou DOA. Não foram observadas diferenças significativas entre as propriedades mecânicas das formulações. Os diferentes plastificantes demonstram influenciar na dureza e resistência química das formulações, sendo que o grupo epóxi e a maior massa molar no plastificante vegetal apresentam maior compatibilidade com a resina de PVC. A análise de MEV apresenta uma provável exudação do plastificante OVM da matriz do PVC.Synthetic polymers have been widely used in manufactured products because of their physical and chemical properties and low cost of production. Poly(vinyl chloride, called PVC, is a versatile, inexpensive plastic whose use has become pervasive in modern society. Its applications include window frames, rain gutters, wall paneling, doors, wallpapers, flooring, garden furniture, toys, blood bags and pipes. In all of these applications additives are used, with plasticizers being among the most important. This work shows a comparative study among distinct

  20. SELECTED PHYSICAL PROPERTIES OF EXTRUDED COMPOSITES TYPE OF POROUS PVC-METAL

    Directory of Open Access Journals (Sweden)

    Aneta Tor-Świątek

    2014-09-01

    Full Text Available The article presents studies of selected physical and mechanical properties of hybrid materials type of polymer-metal. In the frame of this work modification of PVC with the iron and copper powder in amount of 0, 1.5 and 3% and blowing agent in amount of 0, 0.5, 1% was done. Extrudates in a form of pipe were tested to determine density, porosity, maximum tensile stress, stress at break, modulus of elasticity and elongation with break. The samples were also observed in a microscope. The studies have shown significant influence of the added components on the properties tested.

  1. The viability of PVC/Al blister reuse and PVC property studies after ionizing radiation processing

    International Nuclear Information System (INIS)

    Castro, Alex Terela Pinheiro de

    2008-01-01

    The objective of this research was to separate, by means of a process of dissolution, the PVC and the aluminum that compose blister packs, generally used for pharmaceutical pills. We also studied the effect of the ionizing radiation on the PVC, and, finally, the mechanical recycling of the separated PVC, by a process of extrusion. The material we used in this work is the surplus of the pharmaceutical industry, i.e., packs with defects or burrs. We ground the material to facilitate the handling and the homogenization of the system. After that, we chose two bases for the dissolution of the aluminum: the sodium hydroxide and the potassium hydroxide. We used a system with two concentrations (1 and 2M) for each base, and for every solution we had also an agitated and a non-agitated process. From this method resulted eight experiments. After the dissolution, the samples of the material were submitted to ionizing radiation with doses of 50, 100, 150 and 200 kGy in the Dynamitron II electron accelerator of the CTR-IPEN/CNEN-SP. In the following, these samples were submitted to traction resistance tests to analyze which modifications the irradiation caused. The last step of the research was the recycling of the PVC separated from the Aluminum. We made the recycling in industrial equipment, a PVC tube extruder. The material was combined with lubricants, heat stabilizers and pigment in an intensive mixer and processed into the form of rigid PVC electrical conduits. After the eight experiments, the system with potassium hydroxide base, concentration of 2M and agitation presented the best relation between time of dissolution and characteristics of the resulting material, without degradation of the PVC. In the irradiated samples, the color of the material changed as well as its extension that was as larger as the dose of irradiation they received, indicating the dissociation of the PVC molecules. The extrusion of the PVC was successfully realized: about 200 kg (440 pounds) of

  2. Studies on heat shrinkage PVC tubes

    International Nuclear Information System (INIS)

    Pyun, Hyung Chick; Kim, Ki Yup; Nho, Young Chang

    1991-01-01

    Radiation crosslinking of PVC was investigated for the purpose of obtaining a suitable formulation for heat shrinkable tube. PVC was not only compounded with various crosslinking agents and plasticizers to evaluate their effects on the radiation sensitivity, heat shrinkable property and other mechanical properties, but also mixed with NBR, crosslinking agents and plasticizers to obtain efficient crosslinking yield and suitable mechanical properties for heat shrinkable tube. Gel yield of PVC increased with increasing unsaturation levels per molecular weight of crosslinking agents. Among crosslinking agents tested, TMPTMA with three unsaturated groups showed highest gel yield, while PVC containing NBR was more sensitive to crosslinking than PVC itself regardless the types of crosslinking agents and plasticizers. Tensile strength was increased with increasing radiation dose and gel percent, but elongation decreased. It was found that gel percent was increased with increasing radiation dose, heat transformation was decreased with increasing gel percent. When NBR was mixed with PVC, the radiation dosage required for enhancing yield of gel percent and heat transformation were found to be much smaller comparing with the case containing no NBR. Therefore, the addition of NBR to PVC was very effective to increase heat-resisting property of PVC. Heat shrinkage was not much varied with radiation dose, the types of crosslinking agents and plasticizers, but it was increased remarkably with decreasing stretching temperature and increasing annealing temperature. (Author)

  3. Butt-welding technology for double walled Polyethylene pipe

    International Nuclear Information System (INIS)

    Lee, Bo-Young; Kim, Jae-Seong; Lee, Sang-Yul; Kim, Yeong K.

    2012-01-01

    Highlights: ► We developed a butt welding apparatus for doubled walled Polyethylene pipe. ► We design the welding process by analyzing thermal behaviors of the material. ► We performed the welding and tested the welded structural performances. ► We also applied the same technology to PVC pipes. ► We verified the butt welding was successful and effective for the pipes with irregular sections. -- Abstract: In this study, mechanical analyses of a butt welding technology for joining Polyethylene pipe are presented. The pipe had unique structure with double wall, and its section topology was not flat. For an effective repair of leakage and replacements of the pipe, the butt welding technology was developed and tested. For the material characterizations, thermodynamic analyses such as thermal gravimetric analysis and differential scanning calorimetry were performed. Based on the test results, the process temperature and time were determined to ensure safe joining of the pipes using a hot plate apparatus. The welding process was carefully monitored by measuring the temperature. Then, the joined pipes were tested by various methods to evaluate the quality. The analyses results showed the detail process mechanism during the joining process, and the test results demonstrated the successful application of the technology to the sewage pipe repairs.

  4. The viability of PVC/Al blister reuse and PVC property studies after ionizing radiation processing; Viabilizacao do reaproveitamento dos 'blister' de PVC/Al e estudos das propriedades do PVC apos processamento por radiacao ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Alex Terela Pinheiro de

    2008-07-01

    The objective of this research was to separate, by means of a process of dissolution, the PVC and the aluminum that compose blister packs, generally used for pharmaceutical pills. We also studied the effect of the ionizing radiation on the PVC, and, finally, the mechanical recycling of the separated PVC, by a process of extrusion. The material we used in this work is the surplus of the pharmaceutical industry, i.e., packs with defects or burrs. We ground the material to facilitate the handling and the homogenization of the system. After that, we chose two bases for the dissolution of the aluminum: the sodium hydroxide and the potassium hydroxide. We used a system with two concentrations (1 and 2M) for each base, and for every solution we had also an agitated and a non-agitated process. From this method resulted eight experiments. After the dissolution, the samples of the material were submitted to ionizing radiation with doses of 50, 100, 150 and 200 kGy in the Dynamitron II electron accelerator of the CTR-IPEN/CNEN-SP. In the following, these samples were submitted to traction resistance tests to analyze which modifications the irradiation caused. The last step of the research was the recycling of the PVC separated from the Aluminum. We made the recycling in industrial equipment, a PVC tube extruder. The material was combined with lubricants, heat stabilizers and pigment in an intensive mixer and processed into the form of rigid PVC electrical conduits. After the eight experiments, the system with potassium hydroxide base, concentration of 2M and agitation presented the best relation between time of dissolution and characteristics of the resulting material, without degradation of the PVC. In the irradiated samples, the color of the material changed as well as its extension that was as larger as the dose of irradiation they received, indicating the dissociation of the PVC molecules. The extrusion of the PVC was successfully realized: about 200 kg (440 pounds) of

  5. Preparation of a new gamma irradiated PVC-Olive oil cake plastic composite material

    International Nuclear Information System (INIS)

    Messaud, F.A.; Almsmary, Y.A.; Elwerfalli, S.M.; Benayad, S.M.; Haraga, S.O.; Benfaid, N.A.; Kabar, Y.M.

    2003-01-01

    This paper dealt with the investigation on preparing new plastic composite material, utilizing polyvinyl chloride polymer (a commercial product in abu-kammash chemical complex) and olive oil cake (a waste of many olive oil production factories), followed by gamma irradiation (26.3 Kg ry) o induce crosslinking of the polymer. The new material possess good, electrical and mechanical properties as compared to plastic products of (PVC plastic pipe factory), and which could be used as new construction anti corrosive material, such as special roofing and partitioning or household goods

  6. Evaluation of retail fresh meat packagings covered with stretch films of plasticized PVC and non-PVC alternatives

    DEFF Research Database (Denmark)

    Petersen, Jens Højslev; Togeskov, P.; Hallas, J.

    2004-01-01

    The characteristics and performance of several non-PVC stretch films were compared to those of plasticized PVC. Initially the main polymer components Of the film were identified by infrared spectrometry and differential scanning calorimetry. The differences between films in mechanical properties......, such as puncture resistance and tensile strength, varied about a factor of two, while the differences in elongation at break were considerably higher. Plasticized PVC showed properties somewhere in the middle. The water vapour transmission was highest for PVC, while its permeability to oxygen was the lowest...

  7. Heat pipe nuclear reactor for space power

    Science.gov (United States)

    Koening, D. R.

    1976-01-01

    A heat-pipe-cooled nuclear reactor has been designed to provide 3.2 MWth to an out-of-core thermionic conversion system. The reactor is a fast reactor designed to operate at a nominal heat-pipe temperature of 1675 K. Each reactor fuel element consists of a hexagonal molybdenum block which is bonded along its axis to one end of a molybdenum/lithium-vapor heat pipe. The block is perforated with an array of longitudinal holes which are loaded with UO2 pellets. The heat pipe transfers heat directly to a string of six thermionic converters which are bonded along the other end of the heat pipe. An assembly of 90 such fuel elements forms a hexagonal core. The core is surrounded by a thermal radiation shield, a thin thermal neutron absorber, and a BeO reflector containing boron-loaded control drums.

  8. Australia slaps duties on PVC imports

    International Nuclear Information System (INIS)

    Young, I.

    1992-01-01

    The Australian Anti-Dumping Authority (ADA0) has imposed dumping duties on imports of polyvinyl chloride (PVC) resin from seven countries and on certain expanded polystyrene (EPS) beads from Korea and Singapore. The decisions come at the end of two separate investigations begun earlier this year. In its first finding, the ADA concluded that there has been dumping of PVC resin from Canada, China, France, Japan, Norway, Saudi Arabia, and Thailand, which has caused and threatens to cause material injury to the domestic PVC industry. An eighth country, Romania, was found not to have been exporting PVC to Australia. The case is the second of its kind in Australia focusing on PVC. In December 1991 the ADA found in favor of local producer sin a dumping complaint against Argentina, Brazil, Hungary, Israel, Korea, Mexico, Poland, Singapore, Taiwan, and the US

  9. Simulation of air velocity in a vertical perforated air distributor

    Science.gov (United States)

    Ngu, T. N. W.; Chu, C. M.; Janaun, J. A.

    2016-06-01

    Perforated pipes are utilized to divide a fluid flow into several smaller streams. Uniform flow distribution requirement is of great concern in engineering applications because it has significant influence on the performance of fluidic devices. For industrial applications, it is crucial to provide a uniform velocity distribution through orifices. In this research, flow distribution patterns of a closed-end multiple outlet pipe standing vertically for air delivery in the horizontal direction was simulated. Computational Fluid Dynamics (CFD), a tool of research for enhancing and understanding design was used as the simulator and the drawing software SolidWorks was used for geometry setup. The main purpose of this work is to establish the influence of size of orifices, intervals between outlets, and the length of tube in order to attain uniformity of exit flows through a multi outlet perforated tube. However, due to the gravitational effect, the compactness of paddy increases gradually from top to bottom of dryer, uniform flow pattern was aimed for top orifices and larger flow for bottom orifices.

  10. Energy-saving by the optimization of the operation conditions in the vinylcloride lining steel pipe baking furnace. Enbirainingu kokan yakitsukero no sogyo joken saitekika ni yoru sho energy

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Y. (Kawasaki Steel Corp., Tokyo (Japan))

    1991-02-04

    By the investigation of the operation conditions in the small experimental furnace, the improvement of the heat pattern of the steel pipes, and the remodeling and arrangement of the furnace, the progress of the yield and the productivity, and the reduction of the fuel unit were expected. In baking of a PVC pipe with a steel pipe, defects of PVC pipes as the blister of the inner surface occurred often. Accordingly the conditions when the blister occurred were investigated in the experimental furnace and optimized operation conditions when it does not occur were established. Next the flow rate of the hot air and the temperature distribution in the actual furnace were examined and the mechanism of occurrence of the defects of the blister of the inner surface was investigated. As a result, it was proved that the deviation of the hot air flux and the intrusion of the outer air cause it, and the places where the outer air intruded were closed by steel plates. After the improvements the rate of the defects of PVC pipes of the blister of the inner surface was decreased from 5% to 0.5%. Further, by the optimization of the operation conditions the fuel unit decreased and 31% of the rate of the energy-saving was achieved. The reduction of 10,414,000 yen a year was achieved. 29 figs., 4 tabs.

  11. Discoloration of plasticized PVC upon irradiation

    International Nuclear Information System (INIS)

    Kojima, Keiichi; Ueno, Keiji; Kumafuji, Hisao.

    1981-01-01

    The effects of the factors on the discoloration of PVC cross-linked by electron irradiation, such as irradiation dose, the polymerization degree of PVC resin, plasticizers and stabilizers, were studied. The composition of the plasticized PVC used for the experiment was 100 PHR of PVC, 50 PHR of plasticizer, 5 PHR of stabilizer and 5 PHR of cross-linking agent (TMPMA). Three samples with the different degree of polymerization of the PVC resin were used, namely 750, 1050 and 2600. As the plasticizers, phthalic acid esters (DBP, DOP, DIDP), trimellitic acid esters (TOTM, n-TOTM), fatty acid esters (DOS, DOZ), polyester and epoxy group plasticizers were used. The irradiation dose for the test was 3, 6 and 12 Mrad. The experimental results are summarized as follows. As the electron irradiation dose was higher, the resultant discoloration was more remarkable, and the optimum irradiation dose was below 6 Mrad. The degree of polymerization of the PVC resin did not affect the irradiation discoloration. However it was noticed that the cross-linking efficiency was better as the degree of polymerization was higher. The cross-linking efficiency was better as the content of plasticizer was more. The fatty acid esters and epoxy groups showed less discoloration and better cross-linking efficiency. Tin and barium-zinc stabilizers were good. (Kako, I.)

  12. Pipe Penetrating Radar: a New Tool for the Assessment of Critical Infrastructure

    Science.gov (United States)

    Ekes, C.; Neducz, B.

    2012-04-01

    This paper describes the development of Pipe Penetrating Radar (PPR), the underground in-pipe application of GPR, a non-destructive testing method that can detect defects and cavities within and outside mainline diameter (>18 in / 450mm) non-metallic (concrete, PVC, HDPE, etc.) underground pipes. The method uses two or more high frequency GPR antennae carried by a robot into underground pipes. The radar data is transmitted to the surface via fibre optic cable and is recorded together with the output from CCTV (and optionally sonar and laser). Proprietary software analyzes the data and pinpoints defects or cavities within and outside the pipe. Thus the testing can identify existing pipe and pipe bedding symptoms that can be addressed to prevent catastrophic failure due to sinkhole development and can provide useful information about the remaining service life of the pipe. The key innovative aspect is the unique ability to map pipe wall thickness and deterioration including cracks and voids outside the pipe, enabling accurate predictability of needed intervention or the timing of replacement. This reliable non-destructive testing method significantly impacts subsurface infrastructure condition based asset management by supplying previously unattainable measurable conditions. Keywords: pipe penetrating radar (PPR), ground penetrating radar (GPR), pipe inspection, concrete deterioration, municipal engineering

  13. A reciclagem de PVC no Brasil

    OpenAIRE

    Piva,Ana Magda; Bahiense Neto,Miguel; Wiebeck,Hélio

    1999-01-01

    Esta pesquisa discute as possibilidades práticas da reciclagem de PVC. Na reciclagem de polímeros, a do PVC representa uma importante parcela. PVC é um polímero que é usado em uma ampla faixa de produtos: filmes, fios, cabos, em compostos para uma variedade de formas. A reciclagem é uma técnica vantajosa, capaz de reproduzir as propriedades do polímero original, no polímero reciclado e isto em condições razoavelmente econômicas. A tecnologia brasileira, em relação a produtos reciclados, apres...

  14. Radiation crosslinking of PVC with polyfunctional monomers

    International Nuclear Information System (INIS)

    Dobo, J.; Takacs, E.; Csato, P.

    1984-01-01

    The radiation crosslinking of PVC in the presence of ethylene glycol dimethacrylate (EGDM) and of trimethylol propane trimethacrylate (TMPTM) was investigated. The effect of PVC powders of different types on the polymerization rate of these monomers was studied by a Calvet-type microcalorimeter. In the milled PVC sheets containing 50 part EGDM a high concentration of trapped free radicals was found by ESR after 16 months storage. (author)

  15. Hoechst and Wacker plan joint venture in PVC

    International Nuclear Information System (INIS)

    Young, I.

    1992-01-01

    Restructuring of Europe's petrochemical industry has taken a further step with the announcement that Hoechst (Frankfurt) and Wacker Chemie (Munich) are planning a joint venture in polyvinyl chloride (PVC). The venture would include production, R ampersand D, sales and marketing, plus both companies' PVC recycling activities. However, their vinyl chloride monomer (VCM) plants, and Hoechst's Kalle PVC film business, have been left out. Erich Schnitzler, head of Hoechst's PVC business unit, does not anticipate problems with the European Community's competition directorate. We are both among the middle-sized European PVC producers, and together we would have a 9%-10% market share. Our joint venture would not limit competition. Both partners are hoping for approval from Brussels in first-quarter 1993. Hoechst has 255,000 m.t./year of PVC capacity at Gendorfand Knapsack, while Wacker has 365,000 m.t./year at Burghausen and Cologne. All the units, except Wacker's Cologne plant, are back integrated to VCM. The joint venture would buy VCM from the two parent companies and on the merchant market

  16. Gunning for accuracy: Company targets human error with 'foolproof' perforating gun

    Energy Technology Data Exchange (ETDEWEB)

    Ross, E.

    2002-12-01

    An innovative new design for a scalloped expandable perforating gun is described. The gun is manufactured in Edmonton by LRI Perforating Systems, and it aimed at reducing the chances of human error that can result in sub-optimal performance. A perforating gun is used to pierce the well's casing to allow hydrocarbons to flow into the wellbore. It consists of a carrier, a pipe with an eighth-inch thick wall that protects the explosives downhole, and an inner tube containing the explosives. The LRI system has a unique interlocking mechanism for the end plates, which are attached to either end of the thin-walled charge holder tube, in addition to other advantageous features, including a price advantage of 10 to 15 per cent. Marketing strategy is designed to interest wi reline companies that focus on vertical well applications. 1 photo.

  17. Mycelial fungi completely remediate di(2-ethylhexyl)phthalate, the hazardous plasticizer in PVC blood storage bag

    Energy Technology Data Exchange (ETDEWEB)

    Pradeep, S. [Enzyme Technology Laboratory, Biotechnology Division, Department of Botany, University of Calicut, Kerala 673 635 (India); Benjamin, Sailas, E-mail: sailasben@yahoo.co.in [Enzyme Technology Laboratory, Biotechnology Division, Department of Botany, University of Calicut, Kerala 673 635 (India)

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer Three novel phthalate utilizing fungi: A. parasiticus, F. subglutinans and P. funiculosum. Black-Right-Pointing-Pointer Fungi utilize DEHP in PVC plastics in situ, in simple mineral salt medium. Black-Right-Pointing-Pointer Employing these fungi, a batch process can remediate phthalates in plastics. Black-Right-Pointing-Pointer Phthalate-free PVC can be recycled afresh. Black-Right-Pointing-Pointer Mineral salt and phthalate remediated into fungal biomass. - Abstract: This pioneering work describes how simply, inexpensively and efficiently novel fungi utilize the alarming plasticizer, di(2-ethylhexyl)phthalate (DEHP) blended in PVC blood storage bags (BB). In order to quantify total DEHP (33.5%, w/w) present in BB, it was extracted using n-hexane and confirmed by GC-MS. Three mycelial fungi, viz., Aspergillus parasiticus, Fusarium subglutinans and Penicillium funiculosum isolated in our laboratory form heavily plastics-contaminated soil - either singly or in consortium - completely consumed intact DEHP physically bound to BB by static submerged growth (28 Degree-Sign C) in simple basal salt medium (BSM). A two-stage cultivation strategy was adopted for the complete removal of DEHP from BB in situ. During the first growth stage, almost 70% DEHP contained in the BB was consumed in 2 weeks, accompanied by increased fungal biomass ({approx}0.15-0.35 g/g BB; OD {approx}7 at 600 nm) and a sharp declining (3.3) of initial pH (7.2). Spent BSM was replaced at this stagnant growth state (low pH), thus in the second stage, remaining DEHP bound to BB utilized completely (over 99%). Furthermore, A. parasiticus and F. subglutinans also grew well on scrapes of PVC water pipes in BSM. F. subglutinans was as efficient independently as consortium in completely utilizing the DEHP bound to BB, and these fungi offer great potentials for the inexpensive and eco-friendly bioremediation of phthalates in medical and allied PVC wastes on a large

  18. Mycelial fungi completely remediate di(2-ethylhexyl)phthalate, the hazardous plasticizer in PVC blood storage bag

    International Nuclear Information System (INIS)

    Pradeep, S.; Benjamin, Sailas

    2012-01-01

    Highlights: ► Three novel phthalate utilizing fungi: A. parasiticus, F. subglutinans and P. funiculosum. ► Fungi utilize DEHP in PVC plastics in situ, in simple mineral salt medium. ► Employing these fungi, a batch process can remediate phthalates in plastics. ► Phthalate-free PVC can be recycled afresh. ► Mineral salt and phthalate remediated into fungal biomass. - Abstract: This pioneering work describes how simply, inexpensively and efficiently novel fungi utilize the alarming plasticizer, di(2-ethylhexyl)phthalate (DEHP) blended in PVC blood storage bags (BB). In order to quantify total DEHP (33.5%, w/w) present in BB, it was extracted using n-hexane and confirmed by GC–MS. Three mycelial fungi, viz., Aspergillus parasiticus, Fusarium subglutinans and Penicillium funiculosum isolated in our laboratory form heavily plastics-contaminated soil – either singly or in consortium – completely consumed intact DEHP physically bound to BB by static submerged growth (28 °C) in simple basal salt medium (BSM). A two-stage cultivation strategy was adopted for the complete removal of DEHP from BB in situ. During the first growth stage, almost 70% DEHP contained in the BB was consumed in 2 weeks, accompanied by increased fungal biomass (∼0.15–0.35 g/g BB; OD ∼7 at 600 nm) and a sharp declining (3.3) of initial pH (7.2). Spent BSM was replaced at this stagnant growth state (low pH), thus in the second stage, remaining DEHP bound to BB utilized completely (over 99%). Furthermore, A. parasiticus and F. subglutinans also grew well on scrapes of PVC water pipes in BSM. F. subglutinans was as efficient independently as consortium in completely utilizing the DEHP bound to BB, and these fungi offer great potentials for the inexpensive and eco-friendly bioremediation of phthalates in medical and allied PVC wastes on a large scale through a batch process in alleviating the plactics waste management issue.

  19. Chalk effect on PVC cross-linking under irradiation

    International Nuclear Information System (INIS)

    Chudinova, V.V.; Guzeev, V.V.; Mozzhukhin, V.B.; Pomerantseva, Eh.G.; Nozrina, F.D.; Zhil'tsov, V.V.; Zubov, V.P.

    1994-01-01

    Effect of nonmodified and modified chalk on curing degree of polymer matrix was studied under-irradiation of PVC-compositions. Films of the compositions (100 mass part 7 PVC, 0-100 mas.part of chalk, 2.5 - lead sulfate, 1.5 - lead stearate and 0.3 - glycerin) were irradiated up to absorbed dose 0.1 MGy in an inert medium. Content of gel-fraction after boiling in THF was determined with use of IR spectroscopy. It was established, that intensive dehydrochlorination and polymer curing took place on chalk particle surface. Network fixed strongly chalk particles. However, chalk inhibited processes of dehydrochlorination and PVC curing, increasing amount of noncured PVC in polymer matrix

  20. Studies of PVC/ENR blends: blend compositions

    International Nuclear Information System (INIS)

    Chantara Thevy Ratnam; Khairul Zaman Mohd Dahlan; Nasir, M.; Baharin, A.

    2002-01-01

    Blends of poly(vinyl chloride/epoxidized natural rubber (PVC/ENR) were prepared by using Bra bender Plasticorder at compositions ranging from 0-100% PVC. They were blended at 150 degree C mixing temperature, 50 rpm rotor speed and 10 minutes mixing time. The blends were characterized for tensile strength , elongation at break, glass transition temperatures and Fourier transform infra red spectroscopy (FTIR). Results revealed that as the PVC content increases the blend behaviour changes from elastomeric to glassy. However the blends found to be compatible at all compositions. (Author)

  1. Typhoid Intestinal Perforation: 24 Perforations in One Patient

    African Journals Online (AJOL)

    Intestinal perforation is a common cause of peritonitis necessitating emergency surgical intervention. Perforation ... Mortality rates of typhoid intestinal perforation (TIP) cases are ... may be obscured clinical features with resultant delays in.

  2. Radiation cross-linked PVC and its applications

    International Nuclear Information System (INIS)

    Lan Junming; Chen Ruyan; Jia Chaoxing; Li Min; Li Chengxin

    1990-04-01

    The radiation cross-linking technique is adopted for improving the polyvinyl chloride (PVC) heat-resistance and reducing its thermocontractibility. For examining its properties a small insulation sheath made from modified PVC material has been tested at 260 0 5 seconds. The results obtained were satisfactory

  3. Study on dinamic behavior and least burying depth of underground protective pipe

    Energy Technology Data Exchange (ETDEWEB)

    Kataoka, Tetsuyuki; Kokusyo, Goji; Tanaka, Yukihisa; Kobayashi, Seiichi

    1988-03-30

    Effect of unit load per travel wheel on the protective pipe was studied when electricity cable distribution lines were buried in the depth less than the present standard for electric equipment, and logical burying depth was investigated. Test items were material test of the protective pipe, indoor load test, and field test at loamy ground. Impact resistance hard PVC pipe was used as the protective pipe, and its strength and elastic modulus were measured. Along with these tests, it was confirmed that there was no problem of cracking by repeated flattening or breakage by fatigue. By indoor test, it was observed that, in case of shallow burying, creap deformation was small, stress concentrate occured at the middle of axial direction, and that flattening ratio was seriously affected by the method of backfilling. Field test was conducted by applying the static load of a 20 ton dump truck, and the deformation, stress, and subsidence of the protective pipe, were measured. As the conclusion of those experiments, it was found that burying of protective pipe in the depth of not less than 30 cm is allowable, as long as sufficient bakfilling is made. (14 figs, 3 tabs, 3 refs)

  4. Manufacture of mold of polymeric composite water pipe reinforced charcoal

    Science.gov (United States)

    Zulfikar; Misdawati; Idris, M.; Nasution, F. K.; Harahap, U. N.; Simanjuntak, R. K.; Jufrizal; Pranoto, S.

    2018-03-01

    In general, household wastewater pipelines currently use thermoplastic pipes of Polyvinyl Chloride (PVC). This material is known to be not high heat resistant, contains hazardous chemicals (toxins), relatively inhospitable, and relatively more expensive. Therefore, researchers make innovations utilizing natural materials in the form of wood charcoal as the basic material of making the water pipe. Making this pipe requires a simple mold design that can be worked in the scale of household and intermediate industries. This research aims to produce water pipe mold with simple design, easy to do, and making time relatively short. Some considerations for molding materials are weight of mold, ease of raw material, strong, sturdy, and able to cast. Pipe molds are grouped into 4 (four) main parts, including: outer diameter pipe molding, pipe inside diameter, pipe holder, and pipe alignment control. Some materials have been tested as raw materials for outer diameter of pipes, such as wood, iron / steel, cement, and thermoset. The best results are obtained on thermoset material, where the process of disassembling is easier and the resulting mold weight is relatively lighter. For the inside diameter of the pipe is used stainless steel, because in addition to be resistant to chemical processes that occur, in this part of the mold must hold the press load due to shrinkage of raw materials of the pipe during the process of hardening (polymerization). Therefore, it needs high pressure resistant material and does not blend with the raw material of the pipe. The base of the mold is made of stainless steel material because it must be resistant to corrosion due to chemical processes. As for the adjustment of the pipe is made of ST 37 carbon steel, because its function is only as a regulator of the alignment of the pipe structure.

  5. Economic sensitivity of DAW incineration to PVC content

    International Nuclear Information System (INIS)

    Rossmassler, R.L.

    1986-01-01

    Economic analyses of the volume reduction of low level radwaste, including the incinerator of Dry Active Waste (DAW), spent resins and filter sludges, are performed using the microcomputer code VOLREDUCER. Based on BWR and PWR data taken from previous EPRI work, the sensitivity of incinerator economics to polyvinyl chloride (PVC) content in DAW is examined. An annual cost penalty associated with the presence of PVC in the waste is formulated, and the sensitivity of this penalty to a variety of parameters is determined. The alternative of sorting out PVC from the rest of the waste is compared to incineration with regard to this annual cost penalty. These penalties may range as high as $100,000 annually depending on the waste characteristics and percent of PVC

  6. Molecular analysis of long-term biofilm formation on PVC and cast iron surfaces in drinking water distribution system.

    Science.gov (United States)

    Liu, Ruyin; Zhu, Junge; Yu, Zhisheng; Joshi, DevRaj; Zhang, Hongxun; Lin, Wenfang; Yang, Min

    2014-04-01

    To understand the impacts of different plumbing materials on long-term biofilm formation in water supply system, we analyzed microbial community compositions in the bulk water and biofilms on faucets with two different materials-polyvinyl chloride (PVC) and cast iron, which have been frequently used for more than10 years. Pyrosequencing was employed to describe both bacterial and eukaryotic microbial compositions. Bacterial communities in the bulk water and biofilm samples were significantly different from each other. Specific bacterial populations colonized on the surface of different materials. Hyphomicrobia and corrosion associated bacteria, such as Acidithiobacillus spp., Aquabacterium spp., Limnobacter thiooxidans, and Thiocapsa spp., were the most dominant bacteria identified in the PVC and cast iron biofilms, respectively, suggesting that bacterial colonization on the material surfaces was selective. Mycobacteria and Legionella spp. were common potential pathogenic bacteria occurred in the biofilm samples, but their abundance was different in the two biofilm bacterial communities. In contrast, the biofilm samples showed more similar eukaryotic communities than the bulk water. Notably, potential pathogenic fungi, i.e., Aspergillus spp. and Candida parapsilosis, occurred in similar abundance in both biofilms. These results indicated that microbial community, especially bacterial composition was remarkably affected by the different pipe materials (PVC and cast iron). Copyright © 2014 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  7. Structure and performance of ZnO/PVC nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Elashmawi, I.S., E-mail: islam_shukri2000@yahoo.co [Spectroscopy department, Physics division, National Research Centre, Dokki (Egypt); Hakeem, N.A. [Spectroscopy department, Physics division, National Research Centre, Dokki (Egypt); Marei, L.K.; Hanna, F.F. [Faculty of Petroleum and Mining Engineering, Suez Canal University, Suez (Egypt)

    2010-10-01

    ZnO/PVC nanocomposites films have been prepared by the solvent casting method and investigated by various techniques. All results show good dispersion of ZnO nanoparticles in the polymeric matrix. XRD revealed that pure PVC films are partially crystalline with hallow peak but ZnO nanoparticles have wurtzite structure and the nanocomposite films were almost the same as those of ZnO with decrease in the degree of crystallization, causing increase in the amorphous region. FT-IR presented the same spectra for nanocomposites in the wavenumber range 700-3100 cm{sup -1}, weak band located at 500-700 cm{sup -1},which can be attributed to stretching of Zn---O bond and an increase of the bending band of O-H at 1631 cm{sup -1} was observed. The surface of the films was analyzed by SEM, which becomes rough with some small aggregates compared with pure PVC with good distribution in the entire surface region with bright spots. TEM revealed a regular crystalline lattice superimposed on an amorphous background due to carbon support and PVC matrix and the structure of these particles is hexagonal. In addition, the nanocomposites films have higher glass transition temperature, specific heat and thermal stability relative to those of pure PVC because of strong interaction among ZnO nanoparticles and PVC.

  8. Strawberries packaged with Polyvinyl Chloride (PVC film/ Morangos embalados com filme de Ppolicloreto de Vinila (PVC

    Directory of Open Access Journals (Sweden)

    Sergio Ruffo Roberto

    2006-06-01

    Full Text Available Strawberries cv. Dover with approximately 75% of their surface with red color was packaged in disposable polyethylene terephthalate (PET container and sealed with PVC film of 15mm thick. Strawberries without film serves as control. The fruits were stored at 12°C for ten days and there were determined during storage time the titratable acidity, solid soluble and vitamin C contents, color, respiration rate, texture and weight loss. After 6 days the strawberries packaged without film had decayed while the fruits packaged with PVC film were in conditions of consumption and commercialization. After 10 days all fruits were inappropriate to consumption. Packages with PVC film extended the shelf life of strawberries preserving the color characteristic of the product and vitamin C content, reducing the respiration rate and weight loss, characterizing this packaging as being adequate to this kind of product.Foram utilizados morangos cv. Dover com aproximadamente 75% de sua superfície com coloração vermelha e embalados em potes de polietileno tereftalato (PET. No tratamento CONTROLE os morangos foram acondicionados sem filme e no tratamento FILME, as embalagens foram seladas com filme de PVC de 15mm de espessura. As frutas foram armazenadas a 12°C por dez dias e foram determinadas ao longo do tempo acidez titulável, sólidos solúveis, vitamina C, cor, taxa de respiração, textura e perda de massa. Após 6 dias de armazenagem os morangos CONTROLE estavam impróprios para consumo pois apresentavam deterioração visível por bolores enquanto que os embalados com PVC estavam em condições de consumo e comercialização. Após 10 dias todos os morangos estavam impróprios para consumo. A embalagem utilizando filme de PVC aumentou a vida de prateleira de morangos em relação aos sem embalagem pois preservou melhor a coloração característica do produto e teor de vitamina C e reduziu as taxas de respiração e de perda de massa, caracterizando a

  9. Self-Plasticization of PVC via click reaction of a monooctyl phthalate derivative

    Directory of Open Access Journals (Sweden)

    Jia Puyou

    2017-09-01

    Full Text Available Modified PVC (M-PVC material with suppressed migration and low glass transition temperature was prepared via click reaction of a monooctyl phthalate derivative. Chemical structure and composition of M-PVC were characterized by FT-IR, 1H NMR and element analysis. Thermal stability, glass transition temperature and migration stability of M-PVC were studied with TGA, DSC and migration tests, respectively. The study showed that M-PVC exhibited poor thermal stability, and low glass transition temperature of 66.0°C. No migration was found in distilled water, 10% (v/v ethanol, 30% (w/vacetic acid and petroleum ether. The PVC material is expected to preparing PVC products in the areas with high migration resistance requirement.

  10. Effect of radiation on Poly Vinyl chloride (PVC)

    International Nuclear Information System (INIS)

    Massaud, F.; Haraga, S.; Benfaid, N.; Benayad, S.; Kabar, Y.; Elmesmary, Y; Elwerfeli, M.; Omran, Sh.

    1993-01-01

    Radiation crosslinking of polymeric materials is of increasing commercial importance because of the improved thermal, electrical and mechanical properties. Poly Vinylchloride (PVC) is one of the most important polymers. Many attempts were made to study the primary reactions induced by the direct effect of radiation on PVC. In this study, powder PVC was irradiated with different doses at ambient temperature. Formation of free radicals was investigated by electron spin resonance (ESR) method and molecular weight was determined by viscosity measurements. It has been observed that hydrogen chloride was evolved because of noticeable change in color. One type of radical, Poly enyl structure was trapped at room temperature. The non-symmetric singlet structure of the ESR spectra is due to the presence of oxygen. The radical concentration increased with increase of dose. The molecular weight of irradiated PVC was found to be inversely proportional to the increase of radiation dose, which is believed to be due to the occurrence of degradation. It can be concluded that gamma radiation will be the best method for crosslinking of PVC if multi-functional groups or monomers are present. (author)

  11. High Doses Gamma Radiolysis of PVC: Mechanisms of Degradation

    International Nuclear Information System (INIS)

    Colombani, J.

    2006-01-01

    PVC radiolysis leads to the formation of various degradation products: radicals, gas, oxidized products or polyenes. In order to predict the formation of the degradation products with regard to irradiation and ageing parameters, it is important to improve the understanding of the radiolysis mechanisms of PVC. Thus, we used several analytical techniques (Electron Spin Resonance, Fourier Transform Infrared spectroscopy, Nuclear Magnetic Resonance, Size Exclusion Chromatography) to get information on PVC samples irradiated at high doses (up to 4MGy) under different conditions. Gamma irradiation induces the formation of various radicals into PVC. Older studies were generally focused on the effect of low dose and/or low temperature irradiations on PVC. We present here ESR signals of PVC irradiated at high doses and at room temperature. We show that peroxyl radicals are producted by radiolysis under aerobe conditions and that polyenyl radicals are formed under anaerobe conditions. PVC radiolysis induces gas production and especially hydrogen chloride. Production of hydrogen chloride is well known until 1 MGy. We have studied by FTIR, the evolution of the quantity of HCl produced until 4 MGy. We show that higher irradiation dose leads to the lower radiolytic yield of HCl (G(HCl)). Moreover, G(HCl) obtained in aerobe conditions is about fourfold as great as G(HCl) observed in anaerobe radiolysis. Propagation and termination reactions induce degradation products: polyene sequences and crosslinking reactions are observed under anaerobe conditions; oxidized products with addition of chain scissions are formed under aerobe conditions. Although the literature about PVC radiolysis is rich, the main reacting pathways are not well established. Moreover the high doses studies are almost non-existent. We show by FTIR that aerobe radiolysis induces formation of ketons and acids. NMR experiments confirme these results but also focuse on small acids formed (with 2, 3 or 4 carbons). The

  12. Experimental study on dynamic pipe fracture in consideration of hydropower plant model

    Directory of Open Access Journals (Sweden)

    Kazumi Ishikawa

    2009-12-01

    Full Text Available In the case of sudden valve closure, water hammer creates the most powerful pressure and damage to pipeline systems. The best way to protect the pipeline system is to eliminate water hammer. The main reasons for water hammer occurrence are valve closure, high initial velocity, and static pressure. However, it is difficult to eliminate water hammer. Water hammer tends to occur when the valve is being closed. In this study, the pipe fracture caused by static water pressure, gradually increasing pressure, and suddenly increasing pressure were compared experimentally in a breaking PVC test pipe. The quasi-static zone, the dynamic zone, and the transition zone are defined through the results of those experiments, with consideration of the fracture patterns of test pipes and impulses. The maximum pressure results were used to design the pipeline even though it is in the dynamic zone.

  13. Investigation of transient cavitating flow in viscoelastic pipes

    International Nuclear Information System (INIS)

    Keramat, A; Tijsseling, A S; Ahmadi, A

    2010-01-01

    A study on water hammer in viscoelastic pipes when the fluid pressure drops to liquid vapour pressure is performed. Two important concepts including column separation and the effects of retarded strains in the pipe wall on the fluid response have been investigated separately in recent works, but there is some curiosity as to how the results for pressure and discharge are when column separation occurs in a viscoelastic pipe. For pipes made of plastic such as polyethylene (PE) and polyvinyl chloride (PVC), viscoelasticity is a crucial mechanical property which changes the hydraulic and structural transient responses. Based on previous developments in the analysis of water hammer, a model which is capable of analysing column separation in viscoelastic pipes is presented and used for solving the selected case studies. For the column-separation modelling the Discrete Vapour Cavity Model (DVCM) is utilised and the viscoelasticity property of the pipe wall is modelled by Kelvin-Voigt elements. The effects of viscoelasticity play an important role in the column separation phenomenon because it changes the water hammer fundamental frequency and so affects the time of opening or collapse of the cavities. Verification of the implemented computer code is performed for the effects of viscoelasticity and column separation - separately and simultaneously - using experimental results from the literature. In the provided examples the focus is placed on the simultaneous effect of viscoelasticity and column separation on the hydraulic transient response. The final conclusions drawn are that if rectangular grids are utilised the DVCM gives acceptable predictions of the phenomenon and that the pipe wall material's retarded behaviour strongly dampens the pressure spikes caused by column separation.

  14. Investigation of transient cavitating flow in viscoelastic pipes

    Science.gov (United States)

    Keramat, A.; Tijsseling, A. S.; Ahmadi, A.

    2010-08-01

    A study on water hammer in viscoelastic pipes when the fluid pressure drops to liquid vapour pressure is performed. Two important concepts including column separation and the effects of retarded strains in the pipe wall on the fluid response have been investigated separately in recent works, but there is some curiosity as to how the results for pressure and discharge are when column separation occurs in a viscoelastic pipe. For pipes made of plastic such as polyethylene (PE) and polyvinyl chloride (PVC), viscoelasticity is a crucial mechanical property which changes the hydraulic and structural transient responses. Based on previous developments in the analysis of water hammer, a model which is capable of analysing column separation in viscoelastic pipes is presented and used for solving the selected case studies. For the column-separation modelling the Discrete Vapour Cavity Model (DVCM) is utilised and the viscoelasticity property of the pipe wall is modelled by Kelvin-Voigt elements. The effects of viscoelasticity play an important role in the column separation phenomenon because it changes the water hammer fundamental frequency and so affects the time of opening or collapse of the cavities. Verification of the implemented computer code is performed for the effects of viscoelasticity and column separation - separately and simultaneously - using experimental results from the literature. In the provided examples the focus is placed on the simultaneous effect of viscoelasticity and column separation on the hydraulic transient response. The final conclusions drawn are that if rectangular grids are utilised the DVCM gives acceptable predictions of the phenomenon and that the pipe wall material's retarded behaviour strongly dampens the pressure spikes caused by column separation.

  15. Pedicled perforator flaps

    DEFF Research Database (Denmark)

    Demirtas, Yener; Ozturk, Nuray; Kelahmetoglu, Osman

    2009-01-01

    Described in this study is a surgical concept that supports the "consider and use a pedicled perforator flap whenever possible and indicated" approach to reconstruct a particular skin defect. The operation is entirely free-style; the only principle is to obtain a pedicled perforator flap...... to reconstruct the defect. The perforators are marked with a hand-held Doppler probe and multiple flaps are designed. The appropriate flap is elevated after identifying the perforator(s). Dissection of the perforator(s) or complete incision of the flap margins are not mandatory if the flap is mobilized...... adequately to cover the defect. Defects measuring 3 x 3 cm up to 20 x 20 cm at diverse locations were successfully reconstructed in 20 of 21 patients with 26 flaps. Pedicled perforator flaps offer us reliable and satisfactory results of reconstruction at different anatomic territories of the body. It sounds...

  16. PVC removal from mixed plastics by triboelectrostatic separation

    International Nuclear Information System (INIS)

    Park, Chul-Hyun; Jeon, Ho-Seok; Park, Jai-Koo

    2007-01-01

    Ever increasing oil price and the constant growth in generation of waste plastics stimulate a research on material separation for recycling of waste plastics. At present, most waste plastics cause serious environmental problems due to the disposal by reclamation and incineration. Particularly, polyvinyl chloride (PVC) materials among waste plastics generates hazardous HCl gas, dioxins containing Cl, and so on, which lead to air pollution and shorten the life of incinerator, and it makes difficultly recycling of other plastics. Therefore, we designed a bench scale triboelectrostatic separator for PVC removal from mixed plastics (polyvinyl chloride/polyethylene terephthalate), and then carried out material separation tests. In triboelectrostatic separation, PVC and PET particles are charged negatively and positively, respectively, due to the difference of the work function of plastics in tribo charger of the fluidized-bed, and are separated by means of splitter through an opposite electric field. In this study, the charge efficiency of PVC and PET was strongly dependent on the tribo charger material (polypropylene), relative humidity (below 30%), air velocity (over 10 m/s), and mixture ratio (PET:PVC = 1:1). At the optimum conditions (electrode potential of 20 kV and splitter position of -2 cm), PVC rejection and PET recovery in PET products were 99.60 and 98.10%, respectively, and the reproducibility of optimal test was very good (±1%). In addition, as a change of splitter position, we developed the technique to recover high purity PET (over 99.99%) although PET recovery decreases by degrees

  17. Detection of underground water distribution piping system and leakages using ground penetrating radar (GPR)

    Science.gov (United States)

    Amran, Tengku Sarah Tengku; Ismail, Mohamad Pauzi; Ahmad, Mohamad Ridzuan; Amin, Mohamad Syafiq Mohd; Sani, Suhairy; Masenwat, Noor Azreen; Ismail, Mohd Azmi; Hamid, Shu-Hazri Abdul

    2017-01-01

    A water pipe is any pipe or tubes designed to transport and deliver water or treated drinking with appropriate quality, quantity and pressure to consumers. The varieties include large diameter main pipes, which supply entire towns, smaller branch lines that supply a street or group of buildings or small diameter pipes located within individual buildings. This distribution system (underground) is used to describe collectively the facilities used to supply water from its source to the point of usage. Therefore, a leaking in the underground water distribution piping system increases the likelihood of safe water leaving the source or treatment facility becoming contaminated before reaching the consumer. Most importantly, leaking can result in wastage of water which is precious natural resources. Furthermore, they create substantial damage to the transportation system and structure within urban and suburban environments. This paper presents a study on the possibility of using ground penetrating radar (GPR) with frequency of 1GHz to detect pipes and leakages in underground water distribution piping system. Series of laboratory experiment was designed to investigate the capability and efficiency of GPR in detecting underground pipes (metal and PVC) and water leakages. The data was divided into two parts: 1. detecting/locating underground water pipe, 2. detecting leakage of underground water pipe. Despite its simplicity, the attained data is proved to generate a satisfactory result indicating GPR is capable and efficient, in which it is able to detect the underground pipe and presence of leak of the underground pipe.

  18. Electron beam crosslinked PVC : structure property relationships

    International Nuclear Information System (INIS)

    Gupta, Neeraj K.; Sabharwal, Sunil

    2001-01-01

    PVC is used extensively for its insulating properties for the manufacture of wires and cables and for other applications. Its gradual degradation, oxidation and even dehydro chlorination restricts use for long lasting period in installations such as high temperature zones, underground cables, communication systems, electro-nuclear facilities, etc. The technological properties and performance characteristics of PVC based insulation can be improved via crosslinking by high-energy electrons. PVC is however a polymer, which on irradiation predominantly undergoes degradation. To avoid degradation, it needs to be compounded with sensitizing agents or multifunctional monomers so that crosslinking is the predominant reaction. Radiation cross linkable formulations are complex mixtures of resin and various additives incorporated for achieving desired technological and performance characteristics, ease of processing and improving quality. The proper choice of additives and sensitizing agents enable low dose requirements for efficient crosslinking and improvements in various technological properties. The purposes of this work was to investigate the effect of using a binary sensitizer blend of a trifunctional monomer and a rubber in PVC, and develop suitable electron beam cross linkable formulations for wire insulation. This paper presents some aspects of the investigations and development of insulation demonstrated at industrial scale

  19. Desenvolvimento de PVC reforçado com fibras de vidro longas para fabricação de produtos moldados Long glass fiber reinforcement of PVC molding compounds

    Directory of Open Access Journals (Sweden)

    Leandro H. Grizzo

    2011-01-01

    Full Text Available Neste trabalho foi desenvolvido um método para reforçar PVC rígido com fibras de vidro longas através da incorporação pelo processo de recobrimento da fibra contínua com um composto de PVC plastificado. Posteriormente o filamento foi picotado para a formação de grânulos, com fibras de vidro já incorporadas, que foram misturados mecanicamente ao PVC rígido granulado para alimentação direta por moldagem. A moldagem por injeção direta foi realizada com sucesso não sendo necessário a compostagem prévia, o que foi considerado conveniente, pois reduziu as etapas de processamento da resina de PVC e que proporcionou, possivelmente, redução de custos, redução da degradação do comprimento médio das fibras de vidro e diminuição da possibilidade de degradação da resina de PVC. O reforçamento do PVC rígido com 20% em massa de fibras de vidro longas de comprimento inicial entre 13 e 14 mm resultou em adequadas propriedades mecânicas, bem superiores ao PVC rígido não reforçado. Os módulos (tração e flexão e a resistência ao impacto Charpy praticamente dobraram, mesmo com os compósitos apresentando grande quantidade de plastificante em sua formulação, que possibilita ao PVC ser utilizado em outras aplicações não antes possíveis como em peças técnicas de engenharia.In this paper, a method to reinforce rigid PVC with long glass fibers (LGF was developed through the incorporation of continuous glass fibers, as rovings, with plasticized vinyl matrix prepared by the wire coating technique. The plasticized vinyl rovings were pelletized. The pellets (13-14 mm were then blended to a granulated rigid PVC formulation and directly injection molded as testing specimens. The direct injection molding, eliminating the preliminary melt-compounding process, was achieved successfully, which was considered convenient because it reduced the number of processing steps, which allowed cutting expenses, reduced the deterioration of the

  20. Estudo de propriedades de PVC modificado com grupos alquila e benzila Study of the properties of PVC modified through substitution by alkyl and benzyl groups

    Directory of Open Access Journals (Sweden)

    G. M Vinhas

    2005-07-01

    Full Text Available O poli(cloreto de vinila (PVC é o segundo termoplástico mais consumido em todo o mundo, sendo considerado o mais versátil dentre os plásticos. A grande versatilidade do PVC deve-se a suas propriedades e também a sua adequação aos mais variados processos de transformação. Uma vez que a resina de PVC é atóxica e inerte, a escolha de aditivos com essas mesmas características, permite a fabricação de filmes para embalagens de alimentos e produtos médico-hospitalares. Entretanto, suas propriedades podem se alterar quando submetido a qualquer processo de esterilização, especialmente por radiação gama. Neste trabalho foi realizado um estudo sobre a flexibilidade e estabilidade frente à radiação gama do PVC modificado quimicamente. O PVC foi modificado pela substituição de átomos de cloro por grupos alquila e benzila através de reações com reagentes de Grignard. Amostras de PVC modificado foram caracterizadas por espectroscopia de ressonância magnética nuclear de hidrogênio (RMN ¹H, espectroscopia na região do infravermelho com transformada de Fourier e calorimetria diferencial exploratória. A degradação do PVC modificado, quando submetido à radiação gama, foi avaliada por seus parâmetros viscosimétricos. De uma forma geral, o PVC modificado apresentou maior estabilidade à radiação gama que o original. O polímero modificado por substituição do cloro por grupo que contém um anel aromático foi o que apresentou maior estabilidade, quando submetido à dose de esterilização de 25 kGy. O PVC modificado apresentou temperaturas de transição vítrea ligeiramente mais baixas que o PVC original, indicando uma tendência ao aumento de flexibilidade pela presença de grupos alquila e benzila na cadeia do polímero.Poly(vinyl chloride (PVC ranks second among the most consumed thermoplastics in the world, and is considered the most versatile plastic. This versatility arises from its properties and suitability to a

  1. Degradation studies on plasticized PVC films submited to gamma radiation

    Directory of Open Access Journals (Sweden)

    Vinhas Glória Maria

    2003-01-01

    Full Text Available Poly (vinyl chloride, PVC, is a rigid polymer and for several of its applications must be compounded with plasticizing agents. The plasticizers minimize the dipolar interactions, which exist between the polymer's chains, promoting their mobility. In this work we studied the properties of PVC/plasticizer systems submitted to different doses of gamma radiation. We have used four commercial plasticizers amongt them di(2-ethylhexyl phthalate, DEHP, which is present in a great number of commercial applications. The PVC/plasticizer systems have been studied as films made by the solvent evaporation technique. Irradiated and non-irradiated films have been characterized by viscosimetric analysis, mechanical essays and infrared spectroscopy. The results have shown that the rigid, non plasticized, PVC film presented the greatest degradation index, while among the plasticized films the one which presented the larger degradation index due to chain scission was the DEHP plasticized PVC.

  2. Degradation studies on plasticised PVC films submitted to gamma radiation

    International Nuclear Information System (INIS)

    Vinhas, Gloria Maria; Souto-Maior, Rosa Maria; Lapa, Camila Maria; Almeida, Yeda Medeiros Bastos de

    2003-01-01

    Poly (vinyl chloride), PVC, is a rigid polymer and for several of its applications must be compounded with plasticizing agents. The plasticizers minimize the dipolar interactions, which exist between the polymer's chains, promoting their mobility. In this work we studied the properties of PVC/plasticizer systems submitted to different doses of gamma radiation. We have used four commercial plasticizers among them di(2-ethylhexyl) phthalate, DEHP, which is present in a great number of commercial applications. The PVC/plasticizer systems have been studied as films made by the solvent evaporation technique. Irradiated and non-irradiated films have been characterized by viscosimetric analysis, mechanical essays and infrared spectroscopy. The results have shown that the rigid, non plasticized, PVC film presented the greatest degradation index, while among the plasticised films the one which presented the larger degradation index due to chain scission was the DEHP plasticised PVC. (author)

  3. Preparation and characterization of PVC /ENR/CNTs Nano composites

    International Nuclear Information System (INIS)

    Ratnam, C.T.; Nur Azrini Ramlee; Keong, C.C.

    2011-01-01

    Poly (vinyl chloride), PVC/ epoxidized natural rubber blend, ENR/ carbon nano tubes, CNTs were prepared by using melt and solution blending methods. Addition of 2 phr of CNTs found to cause a drop in the tensile strength, Ts of the 50/ 50 PVC/ ENR blend. The nano composites prepared by the melt blending method exhibited higher values of Ts compared to the nano composites prepared by solution blending. Melt blending found to be an efficient method to prepare PVC/ ENR/ CNTs nano composites. (author)

  4. Study on Preparation and Properties of PVC Film Modified by Rare Earth

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The transparent PVC films were prepared by tape casting. In the process of preparation, rare earth nitrate, as a kind of modifier, was added to the solution of PVC and THF. These PVC films were tested after being crosslinked by ultraviolet light. It is found that the mechanical and physical properties of all the PVC films modified by rare earth nitrate are greatly enhanced.

  5. Recycling of PVC Waste via Environmental Friendly Vapor Treatment

    Science.gov (United States)

    Cui, Xin; Jin, Fangming; Zhang, Guangyi; Duan, Xiaokun

    2010-11-01

    This paper focused on the dechlorination of polyvinyl chloride (PVC), a plastic which is widely used in the human life and thereby is leading to serious "white pollution", via vapor treatment process to recycle PVC wastes. In the process, HCl emitted was captured into water solution to avoid hazardous gas pollution and corruption, and remaining polymers free of chlorine could be thermally degraded for further energy recovery. Optimal conditions for the dechlorination of PVC using vapor treatment was investigated, and economic feasibility of this method was also analyzed based on the experimental data. The results showed that the efficiency of dechlorination increased as the temperature increased from 200° C to 250° C, and the rate of dechlorination up to 100% was obtained at the temperature near 250° C. Meanwhile, about 12% of total organic carbon was detected in water solution, which indicated that PVC was slightly degraded in this process. The main products in solution were identified to be acetone, benzene and toluene. In addition, the effects of alkali catalysis on dechlorination were also studied in this paper, and it showed that alkali could not improve the efficiency of the dechlorination of PVC.

  6. Tratamento químico superficial e metalização de ABS, PVC e blendas de PVC/ABS

    Directory of Open Access Journals (Sweden)

    Ana Paula Kurek

    2015-04-01

    Full Text Available Visando à substituição do ABS em peças cromadas, amostras de PVC e blendas de PVC/ABS, na razão mássica de 20/80, 40/60 e 60/40, foram submetidas ao pré-tratamento em solução sulfocrômica sob diferentes condições de concentração, tempo e temperatura e sendo em seguida cromadas. As modificações na superfície das peças após o condicionamento foram analisadas por microscopia eletrônica de varredura, microscopia de força atômica e rugosidade. A qualidade da deposição metálica foi avaliada por inspeção visual e teste de adesão. Os resultados mostraram que, aumentando a concentração de PVC nas peças necessitou-se de condições operacionais mais agressivas, tais como maiores temperaturas de banho, tempo de imersão e concentração de solução sulfocrômica para que ocorresse a adesão da camada metálica. De todas as condições testadas com a solução condicionante sulfocrômica no tratamento das peças de PVC e blendas PVC/ABS de 20/80 e 40/60, a concentração de 350 g/L de ácido crômico e 400 g/L de ácido sulfúrico, temperatura de 70°C e tempo de imersão de 15 minutos, ocasionou deposição do metal em toda a superfície das peças, as quais foram aprovadas nos testes de adesão e corrosão.

  7. Improvement of PVC floor tiles by gamma radiation

    International Nuclear Information System (INIS)

    Plessis, T.A. du; Badenhorst, F.

    1988-01-01

    Gamma radiation presents a unique method of transforming highly plasticized PVC floor tiles, manufactured at high speed through injection moulding, into a high quality floor covering at a cost at least 30% less than similarly rated rubber tiles. A specially formulated PVC compound was developed in collaboration with a leading manufacturer of floor tiles. These tiles are gamma crosslinked in its shipping cartons to form a dimensionally stable product which is highly fire resistant and inert to most chemicals and solvents. These crosslinked tiles are more flexible than the highly filled conventional PVC floor tiles, scratch resistant and have a longer lifespan and increased colour fastness. These tiles are also less expensive to install than conventional rubber tiles. (author)

  8. Differentiating perforated from non-perforated appendicitis on contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Rosenbaum, Daniel G.; Kovanlikaya, Arzu; Askin, Gulce; Beneck, Debra M.

    2017-01-01

    The role of magnetic resonance imaging (MRI) in pediatric appendicitis is increasing; MRI findings predictive of appendiceal perforation have not been specifically evaluated. To assess the performance of MRI in differentiating perforated from non-perforated appendicitis. A retrospective review of pediatric patients undergoing contrast-enhanced MRI and subsequent appendectomy was performed, with surgicopathological confirmation of perforation. Appendiceal diameter and the following 10 MRI findings were assessed: appendiceal restricted diffusion, wall defect, appendicolith, periappendiceal free fluid, remote free fluid, restricted diffusion within free fluid, abscess, peritoneal enhancement, ileocecal wall thickening and ileus. Two-sample t-test and chi-square tests were used to analyze continuous and discrete data, respectively. Sensitivity and specificity for individual MRI findings were calculated and optimal thresholds for measures of accuracy were selected. Seventy-seven patients (mean age: 12.2 years) with appendicitis were included, of whom 22 had perforation. The perforated group had a larger mean appendiceal diameter and mean number of MRI findings than the non-perforated group (12.3 mm vs. 8.6 mm; 5.0 vs. 2.0, respectively). Abscess, wall defect and restricted diffusion within free fluid had the greatest specificity for perforation (1.00, 1.00 and 0.96, respectively) but low sensitivity (0.36, 0.25 and 0.32, respectively). The receiver operator characteristic curve for total number of MRI findings had an area under the curve of 0.92, with an optimal threshold of 3.5. A threshold of any 4 findings had the best ability to accurately discriminate between perforated and non-perforated cases, with a sensitivity of 82% and specificity of 85%. Contrast-enhanced MRI can differentiate perforated from non-perforated appendicitis. The presence of multiple findings increases diagnostic accuracy, with a threshold of any four findings optimally discriminating between

  9. Differentiating perforated from non-perforated appendicitis on contrast-enhanced magnetic resonance imaging.

    Science.gov (United States)

    Rosenbaum, Daniel G; Askin, Gulce; Beneck, Debra M; Kovanlikaya, Arzu

    2017-10-01

    The role of magnetic resonance imaging (MRI) in pediatric appendicitis is increasing; MRI findings predictive of appendiceal perforation have not been specifically evaluated. To assess the performance of MRI in differentiating perforated from non-perforated appendicitis. A retrospective review of pediatric patients undergoing contrast-enhanced MRI and subsequent appendectomy was performed, with surgicopathological confirmation of perforation. Appendiceal diameter and the following 10 MRI findings were assessed: appendiceal restricted diffusion, wall defect, appendicolith, periappendiceal free fluid, remote free fluid, restricted diffusion within free fluid, abscess, peritoneal enhancement, ileocecal wall thickening and ileus. Two-sample t-test and chi-square tests were used to analyze continuous and discrete data, respectively. Sensitivity and specificity for individual MRI findings were calculated and optimal thresholds for measures of accuracy were selected. Seventy-seven patients (mean age: 12.2 years) with appendicitis were included, of whom 22 had perforation. The perforated group had a larger mean appendiceal diameter and mean number of MRI findings than the non-perforated group (12.3 mm vs. 8.6 mm; 5.0 vs. 2.0, respectively). Abscess, wall defect and restricted diffusion within free fluid had the greatest specificity for perforation (1.00, 1.00 and 0.96, respectively) but low sensitivity (0.36, 0.25 and 0.32, respectively). The receiver operator characteristic curve for total number of MRI findings had an area under the curve of 0.92, with an optimal threshold of 3.5. A threshold of any 4 findings had the best ability to accurately discriminate between perforated and non-perforated cases, with a sensitivity of 82% and specificity of 85%. Contrast-enhanced MRI can differentiate perforated from non-perforated appendicitis. The presence of multiple findings increases diagnostic accuracy, with a threshold of any four findings optimally discriminating between

  10. Differentiating perforated from non-perforated appendicitis on contrast-enhanced magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Rosenbaum, Daniel G.; Kovanlikaya, Arzu [New York-Presbyterian Hospital/Weill Cornell Medicine, Division of Pediatric Radiology, New York, NY (United States); Askin, Gulce [Weill Cornell Medical College, Division of Biostatistics and Epidemiology, New York, NY (United States); Beneck, Debra M. [New York-Presbyterian Hospital/Weill Cornell Medicine, Department of Pathology, New York, NY (United States)

    2017-10-15

    The role of magnetic resonance imaging (MRI) in pediatric appendicitis is increasing; MRI findings predictive of appendiceal perforation have not been specifically evaluated. To assess the performance of MRI in differentiating perforated from non-perforated appendicitis. A retrospective review of pediatric patients undergoing contrast-enhanced MRI and subsequent appendectomy was performed, with surgicopathological confirmation of perforation. Appendiceal diameter and the following 10 MRI findings were assessed: appendiceal restricted diffusion, wall defect, appendicolith, periappendiceal free fluid, remote free fluid, restricted diffusion within free fluid, abscess, peritoneal enhancement, ileocecal wall thickening and ileus. Two-sample t-test and chi-square tests were used to analyze continuous and discrete data, respectively. Sensitivity and specificity for individual MRI findings were calculated and optimal thresholds for measures of accuracy were selected. Seventy-seven patients (mean age: 12.2 years) with appendicitis were included, of whom 22 had perforation. The perforated group had a larger mean appendiceal diameter and mean number of MRI findings than the non-perforated group (12.3 mm vs. 8.6 mm; 5.0 vs. 2.0, respectively). Abscess, wall defect and restricted diffusion within free fluid had the greatest specificity for perforation (1.00, 1.00 and 0.96, respectively) but low sensitivity (0.36, 0.25 and 0.32, respectively). The receiver operator characteristic curve for total number of MRI findings had an area under the curve of 0.92, with an optimal threshold of 3.5. A threshold of any 4 findings had the best ability to accurately discriminate between perforated and non-perforated cases, with a sensitivity of 82% and specificity of 85%. Contrast-enhanced MRI can differentiate perforated from non-perforated appendicitis. The presence of multiple findings increases diagnostic accuracy, with a threshold of any four findings optimally discriminating between

  11. ELECTROCHEMICAL OXIDATION OF ETHANOL USING Ni-Co-PVC COMPOSITE ELECTRODE

    Directory of Open Access Journals (Sweden)

    Riyanto Riyanto

    2011-07-01

    Full Text Available The morphological characteristics and electrochemical behavior of nickel metal foil (Ni, nickel-polyvinyl chloride (Ni-PVC and nickel-cobalt-polyvinyl chloride (Ni-Co-PVC electrodes in alkaline solution has been investigated. The morphological characteristics of the electrode surface were studied using SEM and EDS, while the electrochemical behavior of the electrodes was studied using cyclic voltammetry (CV. It was found that composite electrodes (Ni-PVC and Ni-Co-PVC have a porous, irregular and rough surface. In situ studies using electrochemical technique using those three electrodes exhibited electrochemical activity for redox system, as well as selectivity in the electrooxidation of ethanol to acetic acid. The studies also found that an electrokinetics and electrocatalytic activity behaviors of the electrodes prepared were Ni metal foil

  12. Phthalate Migration Study from PVC Grafted by Gamma Radiation

    International Nuclear Information System (INIS)

    Manzoli, J.E.; Duarte, C.; Somesari, E.; Silveira, C.; Paes, H.A.; Manzoli, J.E.; Araujo, F.D.C.; Panzarini, L.C.G.A.

    2009-01-01

    PVC is a useful polymer used for many applications, as packaging of food, blood and in contact with body fluids. The most widely-used plasticizer, to make it flexible, is the phthalate DEHP, and its toxicity is a problem. A special radiation grafting of PVC allows an important reduction of thrombogenic properties, and it could cause changes in the DEHP migration too. In this work it is presented the methodology using gas chromatography and numerical simulation for the measurement of DEHP migration from PVC grafted with monomer DMAEMA. The grafting could be an interesting way to reduce DEHP migration

  13. Spontaneous external gallbladder perforation

    International Nuclear Information System (INIS)

    Noeldge, G.; Wimmer, B.; Kirchner, R.

    1981-01-01

    Spontaneous perforation of the gallbladder is one complication of cholelithiasis. There is a greater occurence of free perforation in the peritoneal cavity with bilary pertonitis, followed by the perforation into the stomach, small intestine and colon. A single case of the nowadays rare spontaneous perforation in and through the abdominal wall will be reported. Spontaneous gallbladder perforation appears nearly asymptomatic in its clinical course because of absent biliary peritonitis. (orig.) [de

  14. The Versatile Modiolus Perforator Flap

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Thomsen, Jorn Bo

    2016-01-01

    BACKGROUND: Perforator flaps are well established, and their usefulness as freestyle island flaps is recognized. The whereabouts of vascular perforators and classification of perforator flaps in the face are a debated subject, despite several anatomical studies showing similar consistency. In our...... experience using freestyle facial perforator flaps, we have located areas where perforators are consistently found. This study is focused on a particular perforator lateral to the angle of the mouth; the modiolus and the versatile modiolus perforator flap. METHODS: A cohort case series of 14 modiolus...... perforator flap reconstructions in 14 patients and a color Doppler ultrasonography localization of the modiolus perforator in 10 volunteers. RESULTS: All 14 flaps were successfully used to reconstruct the defects involved, and the location of the perforator was at the level of the modiolus as predicted...

  15. PVC mixtures’ mechanical properties with the addition of modified calcite as filler

    Directory of Open Access Journals (Sweden)

    Vučinić Dušica R.

    2012-01-01

    Full Text Available In this study mechanical properties of PVC mixtures (PVC, stabilizer, lubricant, filler such as tensile strength, tensile elongation, breaking strength, and breaking elongation were investigated. Unmodified calcite, as well as calcite modified by stearic acid, were used as fillers in wet and dry processes. The PVC mixtures containing the calcite modified by wet procedure have better mechanical properties compared to those with the calcite modified by the dry process. Tensile and breaking strength of the PVC mixture containing the calcite modified with 1.5% stearic acid using wet process, are higher for 2.8% and 5.2%, respectively, compared to the PVC mixture containing the calcite modified with the same amount of acid used in the dry process. The tensile strength difference between the mixtures increases with the increase of the concentration of used stearic acid up to 3%. The strength of PVC mixture with the calcite modified by wet process is 3.1% higher compared to the mixture containing calcite modified by dry process. The results showed that the bonding strength between calcite and the adsorbed organic component affected tensile strength, tensile elongation and breaking strength of the PVC mixtures. The best filler was obtained by wet modification using 1.5% stearic acid solution that provided the formation of a stearate monolayer chemisorbed on calcite. The PVC mixtures containing the calcite modified by wet process using 1.5% stearic acid solution exhibited the best mechanical properties. This calcite was completely hydrophobic with dominant chemically adsorbed surfactant, which means that stearate chemisorbed on calcite provided stronger interaction in the calcite-stearic acid-PVC system.

  16. PVC makers study expansions to meet demand growth

    International Nuclear Information System (INIS)

    Hunter, D.; Coeyman, M.

    1993-01-01

    As prospects for the polyvinyl chloride (PVC) industry continue to improve, the next batch of capacity increases is being studied. Vista Chemical (Houston) sees an opportunity to achieve what company president James R. Ball calls the lowest-cost capacity addition in the market, by debottlenecking its PVC plants at Aberdeen, MS and Oklahoma City. That would increase capacity 40%, adding 300 million lbs/year to Vista's 830 million lbs/year. US demand for PVC grew 12.5% through the first 10 months of 1992, to 7.3 billion lbs, according to the latest figures available from the Society of the Plastics Industry. Alan Bailey, Oxy-Chem's executive v.p./polymers and plastics, predicts a good demand year in 1993 - better even than 1992, driven by an upward trend in housing starts and a recovering economy

  17. RETGEM with polyvinylchloride (PVC) electrodes

    CERN Document Server

    Razin, V I; Reshetin, A I; Filippov, S N

    2009-01-01

    This paper presents a new design of the RETGEM (Resistive Electrode Thick GEM) based on electrodes made of a polyvinylchloride material (PVC). Our device can operate with gains of 10E5 as a conventional TGEM at low counting rates and as RPC in the case of high counting rates without of the transit to the violent sparks. The distinct feature of present RETGEM is the absent of the metal coating and lithographic technology for manufacturing of the protective dielectric rms. The electrodes from PVC permit to do the holes by a simple drilling machine. Detectors on a RETGEM basis could be useful in many fields of an application requiring a more cheap manufacturing and safe operation, for example, in a large neutrino experiments, in TPC, RICH systems.

  18. Influence of pipe material and surfaces on sulfide related odor and corrosion in sewers.

    Science.gov (United States)

    Nielsen, Asbjørn Haaning; Vollertsen, Jes; Jensen, Henriette Stokbro; Wium-Andersen, Tove; Hvitved-Jacobsen, Thorkild

    2008-09-01

    Hydrogen sulfide oxidation on sewer pipe surfaces was investigated in a pilot scale experimental setup. The experiments were aimed at replicating conditions in a gravity sewer located immediately downstream of a force main where sulfide related concrete corrosion and odor is often observed. During the experiments, hydrogen sulfide gas was injected intermittently into the headspace of partially filled concrete and plastic (PVC and HDPE) sewer pipes in concentrations of approximately 1,000 ppm(v). Between each injection, the hydrogen sulfide concentration was monitored while it decreased because of adsorption and subsequent oxidation on the pipe surfaces. The experiments showed that the rate of hydrogen sulfide oxidation was approximately two orders of magnitude faster on the concrete pipe surfaces than on the plastic pipe surfaces. Removal of the layer of reaction (corrosion) products from the concrete pipes was found to reduce the rate of hydrogen sulfide oxidation significantly. However, the rate of sulfide oxidation was restored to its background level within 10-20 days. A similar treatment had no observable effect on hydrogen sulfide removal in the plastic pipe reactors. The experimental results were used to model hydrogen sulfide oxidation under field conditions. This showed that the gas-phase hydrogen sulfide concentration in concrete sewers would typically amount to a few percent of the equilibrium concentration calculated from Henry's law. In the plastic pipe sewers, significantly higher concentrations were predicted because of the slower adsorption and oxidation kinetics on such surfaces.

  19. Method to evaluate stress and deformation of small-sized buried pipe induced by wheel loads. Shokokei maisetsukan no rinkaju ni okeru oryoku henkei hyokaho

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Y.; Kataoka, T.; Kokusho, T.; Yoshida, Y. (Central Research Institute of Electric Power Industry, Tokyo (Japan))

    1994-03-21

    In order to establish a practical method to evaluate safety of buried pipes, which were generally used as cable-protection pipes, at shallow depth and under vehicle loads, a series of experiments and analyses were performed. Based on the results, a simplified method to evaluate stress and deformation of the buried pipes in pavement were proposed. In the experiments, hard PVC pipes, light steel conduit pipes, and corrugated hard PE pipes in nominal diameters from 75 to 200 mm were applied as specimens for representative flexible pipes, and field load tests in actual size as well as laboratory load tests using soil vessels were carried out. The calculated results by the proposed method were compared to the experimental results, finding that the calculated values gave a satisfactory agreement with measured values which were obtained by the field tests. As a result, it was confirmed that the practical method to evaluate circumferential stresses at the top of pipes and flat-deflection ratios of small-sized buried Pipes induced by wheel loads under various conditions were presented. 20 refs., 17 figs., 6 tabs.

  20. Study on the effect of stabilizers on discoloring of PVC by irradiation

    International Nuclear Information System (INIS)

    Peng Chaorong; Wang Jingxia; Chen Zhuping; Liu Siyang

    2009-01-01

    Composites of polyvinyl chloride (PVC) filled with stabilizers was irradiated by 60 Co γ-ray. The effect of different stabilizers on the radiation-induced discoloring of PVC was investigated and the structures of irradiated PVC were characterized by ultraviolet spectrum (UV) and Fourrier transfer infrared spectrum (FT-IR). It shows that the stabilizers including calcium stearate/zinc stearate, epoxidised oil, phosphite and photostabilizer can improve the property of resistance to radiation-induced discoloring of PVC, and phosphite can improve the property of resistance to radiation-induced oxidation of PVC. Among the stabilizers, formulations with calcium stearate/zinc stearate show high transparency and excellent property of resistance to radiation at same absorbed dose. Change rate of yellow index of formulation (calcium stearate: zinc stearate=2:1) has been determined to be 8.3% at the absorbed dose of 30 kGy. It has been found that the structures of PVC with numbers of conjugated double bond or α, β-unsaturated ketone are formed after irradiation by γ-rays. (authors)

  1. Salmonella intestinal perforation: (27 perforations in one patient, 14 perforations in another Are the goal posts changing?

    Directory of Open Access Journals (Sweden)

    Adeniran J

    2005-01-01

    Full Text Available The pathology of salmonellosis after a faeco-oral transmission was first clearly described by Jenner in 1850. Over the years, the pathological manifestations in different tissues of the body have been described. The ileum is however mostly involved leading to enlarged Peyer′s patches, ulceration, and sometimes bleeding and perforation. Efforts at control have largely been improvement in public water supply, safe disposal of waste, and general public health measures. Despite these measures, intestinal perforation from salmonellosis remains the commonest cause of emergency operation in children above 3 years. The incidence continues to rise, so also the mortality, despite new antibiotics and improvement in facilities in the hospitals. Even more disturbing is that we now see more perforations per patient, and more involvement of the colon. Three recently managed patients with multiple ileal/colonic perforations were reviewed. Presenting problems, delay in referral, choice of antibiotics and postoperative complications were noted. One patient had 27 perforations and another 14 perforations. Both survived. Is salmonella changing? Are our patients changing? Is the environment changing? Are the goal posts changing? This article details our recent experience with this dreadful disease, reviews the new literature and makes suggestions for the way forwards.

  2. Studies in cross-linking PVC footwear soling compounds using gamma-irradiation

    International Nuclear Information System (INIS)

    Bloom, L.I.

    1983-01-01

    Irradiation cross-linking of polymeric materials has been known for some time, but it is only in recent years that it has been put to commercial advantage. Well known uses are the modification of PVC for higher temperature applications. Fundamental studies were carried out on amongst other materials, plasticised PVC compounds for use in cable applications. The results of this work, encouraged the author to investigate cross-linkable PVC in areas such as footwear soling

  3. Degradação biológica do PVC em aterro sanitário e avaliação microbiológica Biological degradation of PVC in landfill and microbiological evaluation

    Directory of Open Access Journals (Sweden)

    Ana M. C. Grisa

    2011-01-01

    Full Text Available O poli(cloreto de vinila (PVC é um dos polímeros utilizado no campo das embalagens e no setor calçadista, e, em função da sua aplicação diversificada, apresenta elevados percentuais em aterros domésticos e industriais. É um polímero amorfo podendo apresentar diferentes teores de plastificante e outros aditivos responsáveis pela sua estabilização, os quais podem influenciar no tempo de vida útil e nas propriedades do produto final. Este trabalho apresenta o estudo da degradação química e biológica de filmes de poli(cloreto de vinila flexível (PVC-f, no aterro sanitário São Giácomo, na cidade de Caxias do Sul/RS, antes e após 330 dias de disposição. As amostras de PVC-f antes e após a disposição no aterro sanitário foram avaliadas por análise térmica (TGA, estrutural (FT-IR e morfológica (MEV e MO. Observou-se que as amostras de PVC-f dispostas no aterro sanitário (PVC-fa, apresentam um único evento de perda de massa, em relação ao PVC-f não degradado ou virgem (PVC-fv, além de um maior % de perda de massa e de mudanças estruturais. Nas amostras de PVC-fa foram observadas modificações morfológicas importantes para descrever os fenômenos de degradação como erosão da superfície, bioerosão, que propiciaram a ação das leveduras, bactérias e fungos presentes no meio no polímero aterrado.The poly (vinyl chloride (PVC is one of the polymers used in the field of packing materials and footwear sector, and due its diversified applications, it has presented in a high percentage of domestic and industrial landfills It is an amorphous polymer and may present different levels of plasticizer and other additives responsible for its stabilization, which can influence the lifetime and the properties of the final product. This work presents the study of the chemical and biological degradation of poly (vinyl chloride flexible (PVC-f films, at São Giácomo landfill, in Caxias do Sul city after 330 days of

  4. The development of PVC-laminated steel sheet by an electron beam curing method

    International Nuclear Information System (INIS)

    Masuhara, Ken-ichi; Koshiishi, Kenji; Tomosue, Takao; Mori, Koji; Honma, Nobuyuki

    1988-01-01

    Polyvinyl chloride (PVC) film-laminated steel sheets are used for household electric appliances and building materials. Those are produced usually by pressing a PVC film onto a steel sheet imediately after a themosetting adhesive has been applied to the sheet and curing. However, a major problem of this method is that the appearance of the PVC films such as gloss and embossment changes during pressing due to the heat that is required for causing bonding, therefore, the development of an adhesive which can be cured at lower temperature is necessary. Nisshin Steel Co., Ltd. has developed PVC film-laminated steel sheets for which electron beam (EB) curable adhesives are used to overcome this problem. The advantage of these adhesives is that they can be quickly cured at room temperature. The production procedure of PVC-laminated steel sheets by EB curing is outlined. But this method has encountered two problems: poor adhesion between substrates and adhesive due to the residual stress, and the deterioration of the PVC films due to EB irradiation. EB curable adhesives are mainly composed of acrylic ester oligomers and monomers, and thier adhesion was improved by organic pretreatment. On the other hand, EB-proof PVC films were developed. The general properties of PVC-laminated steel sheets produced by EB curing are reported. (K.I.)

  5. Change Spectroscopic, thermal and mechanical studies of PU/PVC blends

    Energy Technology Data Exchange (ETDEWEB)

    Hezma, A.M. [Spectroscopy Department, Physics Division, National Research Center, Giza (Egypt); Elashmawi, I.S. [Spectroscopy Department, Physics Division, National Research Center, Giza (Egypt); Physic Department, Faculty of Science, Taibah University, Al-Ula (Saudi Arabia); Rajeh, A., E-mail: a.rajeh88@yahoo.com [Physic Department, Faculty of Science, Amran University, Sa' dah (Yemen); Physics Department, Faculty of science, Mansoura University, Mansoura (Egypt); Kamal, Mustafa [Physics Department, Faculty of science, Mansoura University, Mansoura (Egypt)

    2016-08-15

    Blends of polyurethane (PU) and polyvinyl chloride (PVC) with different concentrations were prepared by casting method. The effects of PU on PVC blends was examined by Fourier transform-infrared (FTIR), Ultra-violet visible studies (UV/VIS.), X-ray diffraction (XRD), Thermogravimetric (TGA), Differential scanning calorimetry (DSC), and mechanical properties (stress–strain curve). The interaction between PU and PVC was examined by FT-IR through the absorbance of the N–H groups and was correlated to mechanical/thermal properties. Ultra-violet visible said that optical energy gap decrease with increasing concentration of PU. Differential scanning calorimetry results was observed a single glass transition temperature (T{sub g}) for blends this confirming existence miscibility within the blends. The causes for best thermal stability of some blends may be described by measurements of interactions between C=O groups of PU and the α-hydrogen of PVC or a dipole–dipole –C=O..Cl–C– interactions. Significant alterations in FTIR, X-ray and DSC examination shows an interactions between blends had good miscibility. X-ray shows some alterations in the intensity with additional PU. PU change the mechanical behavior of PVC through of the blends. When polyurethane content increase causes polyvinyl chloride tensile strength decreases and elongation at break increase.

  6. The role of chlorine and additives of PVC-plastic in combustion

    International Nuclear Information System (INIS)

    Mattila, H.

    1991-01-01

    The PVC differs from other common plastics due to the chlorine content. As the PVC is combusted, the chlorine is released mainly as hydrogen chloride. The content of chlorinated hydrocarbons is small, but these can also contain polychlorinated dibenzofuranes and dibenzodioxines, which are extremely poisonous. The aim of this study was to find out, what is the portion of PVC combustion in total emission of chlorinated hydrocarbons. Additionally, the amounts chlorine coming into combustion process with ordinary fuels have been estimated, and they are compared with the amounts of PVC. The chloride content of municipal wastes vary in between 0.4-0.9 %. The portion of plastics is about 30 % of the total, and the rest being from paper, food , wood and garden wastes an textiles. Both organic and inorganic chlorine form gaseous hydrogen chlorid in combustion processes. HCl can then react with oxygen and produce caseous chlorine. This can react with unreacted carbon of the smoke and produce different kinds of chlorinated hydrocarbons. The portion of PVC of the chlorine going into combustion in Finland has been estimated to be about 1-2 %. Combustion tests were made using coal and bark and plastic waste as additional fuel. It was noticed that addition of plastic decreased the amount of polyaromatic hydrocarbons in the smoke. Chlorinated dioxins and furans occurred a little less in the gases of combustion of plastic mixtures not containing PVC than in reference tests, but they increased when PVC containing plastic mixture was combusted, but more chlorinated dioxins and furans were absorbed into fly ash, so the emissions remained almost the same

  7. Differentiation of Acute Perforated from Non-Perforated Appendicitis: Usefulness of High-Resolution Ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Gyu Chang [Dept. of Radiology, Gumi Hospital, Soonchunhyang University College of Medicine, Gumi (Korea, Republic of)

    2011-07-15

    To evaluate the usefulness of high-resolution ultrasonography (US) for the differentiation of acute perforated appendicitis from non-perforated appendicitis. The high-resolution US features in 96 patients (49 males, 47 females; mean age, 33.8 years; age range, 4-80 years) with pathologically proven acute appendicitis were evaluated. The following US findings were evaluated for differentiation of acute perforated appendicitis from non-perforated appendicitis: circumferential loss of the echogenic submucosal layer, periappendiceal fluid collection, disruption of the serosal layer, asymmetrical wall thickening, maximum overall diameter > 10.5 mm, and the presence of appendicoliths. The sensitivity and specificity of the US features in the diagnosis of acute perforated appendicitis were calculated. All of the US findings, except for appendicoliths, were significantly more common in the acute perforated appendicitis group (p < 0.001). The sensitivity of circumferential loss of the echogenic submucosal layer, periappendiceal fluid collection, disruption of the serosal layer, asymmetrical wall thickening, maximum overall diameter > 10.5 mm, and the presence of appendicoliths was 85.4, 73.2, 68.3, 70.7, 80.5, and 36.6%, respectively, while the specificity was 65.5, 89.1, 96.4, 98.2, 81.8, and 80.0%, respectively. High-resolution US was found to be useful for differentiating acute perforated appendicitis from non-perforated appendicitis.

  8. Nontraumatic terminal ileal perforation

    Directory of Open Access Journals (Sweden)

    Wani Rauf A

    2006-03-01

    Full Text Available Abstract Background There is still confusion and controversy over the diagnosis and optimal surgical treatment of non traumatic terminal ileal perforation-a cause of obscure peritonitis. Methods This study was a prospective study aimed at evaluating the clinical profile, etiology and optimal surgical management of patients with nontraumatic terminal ileal perforation. Results There were 79 cases of nontraumatic terminal ileal perforation; the causes for perforation were enteric fever(62%, nonspecific inflammation(26%, obstruction(6%, tuberculosis(4% and radiation enteritis (1%. Simple closure of the perforation (49% and end to side ileotransverse anastomosis(42% were the mainstay of the surgical management. Conclusion Terminal ileal perforation should be suspected in all cases of peritonitis especially in developing countries and surgical treatment should be optimized taking various accounts like etiology, delay in surgery and operative findings into consideration to reduce the incidence of deadly complications like fecal fistula.

  9. Structural, optical and thermal characterization of PVC/SnO2 nanocomposites

    Science.gov (United States)

    Taha, T. A.; Ismail, Z.; Elhawary, M. M.

    2018-04-01

    The structural, optical, and thermal properties of PVC/SnO2 nanocomposites were investigated. XRD patterns were used to explore the structures of these prepared samples. Optical UV-Vis measurements were analyzed to calculate the spectroscopic optical constants of the prepared PVC/SnO2 nanocomposites. Both direct and indirect optical band gaps decreased with increasing SnO2 content. The refractive index, high frequency dielectric constant, plasma frequency, and optical conductivity values increased with SnO2. The single oscillator energy increased from 5.64 to 10.97 eV and the dispersion energy increased from 6.35 to 19.80 eV with the addition of SnO2. The other optical parameters such as optical moments, single oscillator strength, volume energy loss, and surface energy loss were calculated for different SnO2 concentrations. Raman spectra of the PVC/SnO2 nanocomposite films revealed the characteristic vibrational modes of PVC and surface phonon modes of SnO2. The thermal stability of PVC/SnO2 nanocomposite films was studied using DTA and thermogravimetric analysis. The glass transition ( T g) values abruptly changed from 46 °C for PVC to an average value of 59 °C for the polymer films doped with 2.0, 4.0, and 6.0 wt% SnO2. The weight loss decreased as the SnO2 concentration increased in the temperature range of 350-500 °C, corresponding to enhanced thermal stability.

  10. Estado de mistura e dispersão da fase borrachosa em blendas PVC/NBR Phase separation and rubber phase dispersion in PVC/NBR blends

    Directory of Open Access Journals (Sweden)

    Fábio R. Passador

    2006-01-01

    Full Text Available Termoplásticos modificados com elastômeros têm despertado grande interesse de pesquisadores e de indústrias devido à atraente relação custo/benefício e a possibilidade de aumento significativo da tenacidade sob impacto de polímeros frágeis com a incorporação de uma fase borrachosa dispersa. Este artigo mostra a relação entre o estado de mistura e a dispersão da fase borrachosa em blendas de poli (cloreto de vinila (PVC com borracha nitrílica (NBR. O estado de mistura de blendas poliméricas é um fator muito importante a ser considerado no desenvolvimento destes tipos de materiais, uma vez que determina o nível de mistura molecular das blendas. A característica estrutural do PVC é responsável pela morfologia das blendas PVC/NBR, sendo que há uma otimização de propriedades mecânicas quando as partículas de borracha formam a morfologia "pseudo-network", ou seja, quando as partículas de borracha estão randomicamente dispersas entre as partículas primárias do PVC.Thermoplastics modified with elastomers have attracted great interest of researchers and industries due to the low cost/benefit relationship and the possibility of significant increase in the toughness of brittle polymers through the incorporation of a dispersed rubber phase. This article shows the relationship between the interaction between phases and rubber phase dispersion in poly (vinyl chloride/nitrile rubber blends. The interaction between components in polymer blends is an important factor to be considered in the development of this kind of materials because it determines the level of the mixture at the molecular level. The particulate nature of PVC and the degree of nitrile groups in the NBR are responsible to the PVC/NBR blends morphologies leading to an optimization of the mechanical properties when the rubber particles form a pseudo-network morphology with the rubber particles randomly dispersed in between the PVC primary particles.

  11. Bedside identification of patients at risk for PVC-induced cardiomyopathy: Is ECG useful?

    Science.gov (United States)

    Garster, Noelle C; Henrikson, Charles A

    2017-07-01

    Premature ventricular complexes (PVCs) are an underrecognized cause of cardiomyopathy. Standard 12-lead electrocardiogram (ECG) has potential to direct attention toward at-risk patients. We performed a single-center, retrospective chart review of 1,240 patients who completed ECG and Holter monitoring at Oregon Health and Science University Hospital between January 1, 2011 and December 31, 2013 to investigate the relationship of PVC frequency on ECG with burden on Holter. Primary outcome measures included PVC quantity on ECG, mean PVC quantity on Holter, and percentage of total beats on Holter recorded as PVCs. High PVC burden was defined as ≥10% of total beats. Weighted mean percentages of total beats on Holter monitor recorded as PVCs were calculated for 0, 1, 2, and ≥3 PVCs on ECG and found to be 1.4% (n = 1,128), 3.5% (n = 32), 4.3% (n = 25), and 16.6% (n = 55), respectively, which represent statistically significant differences (P ECG for ≥10% PVC Holter burden was 58%. Negative predictive value for 0 PVCs on ECG was 98%. The sensitivity and specificity of ECG to identify high PVC burden on Holter was 72% and 93.6%, respectively, when utilizing a positive ECG result as one PVC or more, and 44% and 98.9%, respectively, with ≥3 PVCs on ECG. The positive likelihood ratio corresponding to ≥3 PVCs on ECG was 40. These findings demonstrate that the number of PVCs on ECG can be utilized for quick bedside estimation of high PVC burden. © 2017 Wiley Periodicals, Inc.

  12. Near infrared reflectance spectroscopy for the fast identification of PVC-based films.

    Science.gov (United States)

    Laasonen, M; Rantanen, J; Harmia-Pulkkinen, T; Michiels, E; Hiltunen, R; Räsänen, M; Vuorela, H

    2001-07-01

    Near infrared (NIR) reflectance spectroscopy was used to develop a non-destructive and rapid qualitative method for the analysis of plastic films used by the pharmaceutical industry for blistering. Three types of films were investigated: 250 microm PVC [poly(vinyl chloride)] films, 250 microm PVC films coated with 40 g m(-2) of PVDC [poly(vinylidene dichloride)] and 250 microm PVC films coated with 5 g m(-2) of TE (Thermoelast) and 90 g m(-2) of PVDC. Three analyses were carried out using different pre-treatment options and a PLS (partial least squares) algorithm. Each analysis was aimed at identifying one type of film and rejecting all types of false sample (different thickness, colour or layer). True and false samples from four plastics manufacturers were included in the calibration sets in order to obtain robust methods that were suitable regardless of the supplier. Specificity was demonstrated by testing validation sets against the methods. The tests showed 0% of type I (false negative identification) and 1% of type II errors (false positive identification) for the PVC method, 13 and 3%, respectively, for the PVC-PVDC method and no error for the PVC-TE-PVDC method. Type II errors, mostly due to the slight sensitivity of the methods to film thickness, are easily corrected by simple thickness measurements. This study demonstrates that NIR spectroscopy is an excellent tool for the identification of PVC-based films. The three methods can be used by the pharmaceutical industry or plastics manufacturers for the quality control of films used in blister packaging.

  13. The Paradigms They Are a-Changin': past, present and future of PVC bacteria research.

    Science.gov (United States)

    Rivas-Marín, Elena; Devos, Damien P

    2018-06-01

    These are exciting times for PVC researchers! The PVC superphylum is composed of the bacterial phyla Planctomycetes, Verrucomicrobia, Chlamydiae (those three founders giving it its name), Lentisphaerae and Kirimatiellaeota as well as some uncultured candidate phyla, such as the Candidatus Omnitrophica (previously known as OP3). Despite early debates, most of the disagreements that surround this group of bacteria have been recently resolved. In this article, we review the history of the study of PVC bacteria, with a particular focus on the misinterpretations that emerged early in the field and their resolution. We begin with a historical perspective that describes the relevant facts of PVC research from the early times when they were not yet termed PVC. Those were controversial times and we refer to them as the "discovery age" of the field. We continue by describing new discoveries due to novel techniques and data that combined with the reinterpretations of old ones have contributed to solve most of the discordances and we refer to these times as the "illumination age" of PVC research. We follow by arguing that we are just entering the "golden age" of PVC research and that the future of this growing community is looking bright. We finish by suggesting a few of the directions that PVC researches might take in the future.

  14. Physicomechanical properties of PVC radiation-modified by tridecaethyleneglycol methacrylic ester

    International Nuclear Information System (INIS)

    Lomonosova, N.V.

    1988-01-01

    A study was made on physicomechanical properties of radiation-modified system on the basis of PVC and TGM-13 oligomer (dimethacrylic ester of tridecaethyleneglycol, 43.2%). Main physical properties of the composition (maximal stresses, softening point, double refraction value, activation energy, temperature positions of the first and the second maximums on isometric heating diagram) were used to determine its isotropic and oriented states, depending on absorbed radiation dose (0-128 kGy). It is shown that radiation PVC modification by TGM-13 oligomer results in formation of linked 'soft' plastic. In terms of strength it is on a par with isotropic linear PVC, but compare favourably with it with respect to t ρ and ε

  15. Investigation of Ice-PVC separation under Flexural Loading using FEM Analysis

    Directory of Open Access Journals (Sweden)

    H Xue

    2016-08-01

    Full Text Available This paper presents the FEM technique applied in the study of ice separation over a polyvinyl chloride (PVC surface. A two layer model of ice and PVC is analysed theoretically using Euler-Bernoulli beam theory and the rule of mixtures. The physical samples are prepared by freezing ice over the PVC surfaces. The samples are tested experimentally in a four-point loading setup. The experimental results contain strain data gathered through a data acquisition system using the LabView software. The data is collected at the rate of 1 kHz per load step. A model is also coded in MATLAB® and simulated using the finite element method (FEM in ANSYS® Multiphysics. The FEM model of the ice and PVC sample is built using solid elements. The mesh is tested for sensitively. A good agreement is found between the theoretical, experimental and numerical simulation results.

  16. Reactive perforating collagenosis

    Directory of Open Access Journals (Sweden)

    Yadav Mukesh

    2009-01-01

    Full Text Available Reactive perforating collagenosis is a rare cutaneous disorder of unknown etiology. We hereby describe a case of acquired reactive perforating collagenosis in a patient of diabetes and chronic renal failure.

  17. Combining rhinoplasty with septal perforation repair.

    Science.gov (United States)

    Foda, Hossam M T; Magdy, Emad A

    2006-11-01

    A combined septal perforation repair and rhinoplasty was performed in 80 patients presenting with septal perforations (size 1 to 5 cm) and external nasal deformities. The external rhinoplasty approach was used for all cases and the perforation was repaired using bilateral intranasal mucosal advancement flaps with a connective tissue interposition graft in between. Complete closure of the perforation was achieved in 90% of perforations of size up to 3.5 cm and in only 70% of perforations that were larger than 3.5 cm. Cosmetically, 95% were very satisfied with their aesthetic result. The external rhinoplasty approach proved to be very helpful in the process of septal perforation repair especially in large and posteriorly located perforations and in cases where the caudal septal cartilage was previously resected. Our results show that septal perforation repair can be safely combined with rhinoplasty and that some of the routine rhinoplasty maneuvers, such as medial osteotomies and dorsal lowering, could even facilitate the process of septal perforation repair.

  18. Comparative Study of PVC-Free All-Solid-State, PVC Membrane, and Carbon Paste Ion-Selective Electrodes for the Determination of Dapoxetine Hydrochloride in Pharmaceutical Formulation.

    Science.gov (United States)

    Aziz, Azza; Khamees, Nesrin; Mohamed, Tagreed Abdel-Fattah; Derar, Abeer Rashad

    2016-11-01

    The potentiometric response characteristics and analytical applications of a poly(vinyl chloride) (PVC)-free all-solid-state ion-selective electrode for dapoxetine hydrochloride (DAP) are examined. The Nernstian response of the electrode was evaluated by comparison with PVC-based liquid membrane and carbon paste electrodes. The PVC-free electrode is prepared by direct incorporation of dapoxetine-tetraphenyl borate (DAP-TPB) as a sensing element into a commercial nail varnish containing cellulose acetate propionate. The composite was applied onto a 3 mm diameter graphite disk electrode. The electrode exhibited a Nernstian slope of 56.0 mV/decade in the concentration range of 1 × 10-4 to 1 × 10-2 mol/L with an LOD of 2 × 10-5 mol/L. The electrode is independent of pH in the range of 2 to 6 and showed good selectivity for DAP with respect to a large number of inorganic cations and amino acids. Comparable Nernstian slope, sensitivity, pH range, and selectivity pattern were obtained with a PVC membrane and a carbon paste incorporating DAP-TPB as a sensing element and dioctylphthalate as a solvent mediator. The electrodes were used for the determination of DAP in pure solution and in tablets without extraction with high accuracy and precision (RSD ≤ 2%). The nail varnish solid-state electrode is simple, economical, and rapid when compared with PVC membrane and carbon paste electrodes.

  19. Spectrum of Perforation Peritonitis

    Science.gov (United States)

    Chakma, Sujit M.; Singh, Rahul L.; Parmekar, Mahadev V.; Singh, K.H. Gojen; Kapa, Buru; Sharatchandra, K.H.; Longkumer, Amenla T.; Rudrappa, Santhosh

    2013-01-01

    Introduction: Perforation peritonitis mostly results from the perforation of a diseased viscus. Other causes of perforation include abdominal trauma, ingestion of sharp foreign body and iatrogenic perforation. The diagnosis is mainly based on clinical grounds. Plain abdominal X-rays (erect) may reveal dilated and oedematous intestines with pneumoperitoneum. Ultrasound and CT scan may diagnose up to 72% and 82% of perforation respectively. The present study was carried out to study various etiological factors, modes of clinical presentation, morbidity and mortality patterns of perforation peritonitis presented in the RIMS hospital, Imphal, India. Material and Methods: The study was conducted from September 2010 to August 2012 on 490 cases of perforation peritonitis admitted and treated in the Department of Surgery. Initial diagnosis was made on the basis of detailed history, clinical examination and presence of pneumoperitoneum on erect abdominal X-ray. Results: A total of 490 patients of perforation peritonitis were included in the study, with mean age of 48.28 years. 54.29% patients were below 50 years and 45.71% patients were above 50 years. There were 54.29% male patients and 45.71% female patients. Only 30% patients presented within 24 hours of onset of symptoms, 31.43% patients presented between 24 to 72 hours and 38.57% patients presented 72 hours after the onset of symptoms. Mean duration of presentation was 54.7 hours. Overall 469 patients were treated surgically and 21 patients were managed conservatively. Overall morbidity and mortality recorded in this study were 52.24% and 10% respectively. PMID:24392388

  20. Estudo do comportamento de compostos de PVC com adição de amido Study of the behavior of PVC compounds with added starch

    Directory of Open Access Journals (Sweden)

    Lisandra Abatti

    2011-01-01

    Full Text Available Este trabalho apresenta o estudo do comportamento de compostos de PVC com adição de amido para aplicação especialmente na indústria calçadista. As propriedades mecânicas dos compostos nas proporções de 5, 7,5 e 10% foram estudadas através de ensaios de tração. Também foram verificados os índices de fluidez, alterações de propriedades quando submetidos ao envelhecimento artificial em estufa e natural ao expor às intempéries e enterrar no solo. A viabilidade da aplicação na indústria calçadista foi feita por injeção em gáspeas e tiras de sandálias, com testes de resistência, flexão e testes de campo. Os resultados demonstraram que o acréscimo de amido ao PVC provoca perda nas propriedades mecânicas, justificado pela baixa resistência mecânica do amido em relação ao PVC. Após envelhecimento em estufa o processo de retrogradação do amido deixa os compostos mais rígidos e com menor fluidez. Quando expostos às intempéries e ao solo, o PVC pode ser degradado com perda de HCl, o que leva à acidificação do solo. Nas aplicações em calçados e sandálias a resistência mecânica não atende aos requisitos do mercado. Apesar do baixo custo, o fraco comportamento mecânico dificulta sua viabilização para substituição em escala.This paper deals with the behavior of PVC compounds with addition of starch for applications, especially in the footwear industry. The mechanical properties of the compounds in the proportions of 5, 7.5 and 10% were studied using tensile tests. Also investigated were the flow rates, in addition to changes in properties when the material was subjected to artificial aging in an oven and exposed to natural weather and buried in the soil. The feasibility of application in the industry was evaluated with tests of endurance, strength and field tests in injection uppers and straps of sandals. The results showed that the addition of starch to PVC causes loss of mechanical properties, owing to

  1. Perforations during contrast enema

    International Nuclear Information System (INIS)

    Vogel, H.; Steinkamp, U.; Grabbe, E.; Allgemeines Krankenhaus Ochsenzoll, Hamburg

    1983-01-01

    During contrast enema, perforation into the retroperitoneal space can be differentiated from perforation into the peritoneum and perforation into the intestinal wall associated with formation of barium granulomas or submucosal spreading of the contrast medium. Other special forms are perforation with contrast medium embolism of diverticula; of the processus vermiformis; penetration of contrast medium into fistulous systems and from the operated areas. Risk factors are: balloon catheter, intestinal tubes with a hard tip, preternatural anus, excessive enema pressure, contrast medium additions, preceding manipulations, intestinal diseases, advanced age and delegation of manipulations to assistants and unskilled staff. Children are particularly at risk. (orig.) [de

  2. Electrochemical Behaviour of Ni and Ni-PVC Electrodes for the Electroxidation of Ethanol

    International Nuclear Information System (INIS)

    Mohd Syafiq Hamdan; Norazzizi Nordin; Siti Fathrita Mohd Amir; Riyanto; Mohamed Rozali Othman

    2011-01-01

    In this study, two nickel based electrodes were prepared; nickel foil and nickel-polyvinylchloride (Ni-PVC), in order to study their electrochemical behavior using cyclic voltammetry, CV and chronocoulometry, CC. Ni electrode was prepared from Ni metal foil while Ni-PVC electrode was prepared by mixing a weighed portion of Ni powder and PVC in THF solvent, swirled until the suspension was homogeneous and drying the suspension in an oven at 50 degree Celsius for 3 h. The dry sample was then placed in a 1 cm diameter stainless steel mould and pressed at 10 ton/ cm 2 . From CV data, Ni-PVC electrode showed a better electrochemical behavior compared to Ni metal foil electrode. The use of Ni-PVC electrode at higher concentration of supporting electrolyte (1.0 M KOH) was better than at lower concentration of the same supporting electrolyte in electroxidation of ethanol. In addition to acetic acid, the oxidation of ethanol also produced ethyl acetate and acetaldehyde. (author)

  3. An Enhanced Soft Vibrotactile Actuator Based on ePVC Gel with Silicon Dioxide Nanoparticles.

    Science.gov (United States)

    Park, Won-Hyeong; Shin, Eun-Jae; Yun, Sungryul; Kim, Sang-Youn

    2018-01-01

    In this paper, we propose a soft vibrotactile actuator made by mixing silicon dioxide nanoparticles and plasticized PVC gel. The effect of the silicon dioxide nanoparticles in the plasticized PVC gel for the haptic performance is investigated in terms of electric, dielectric, and mechanical properties. Furthermore, eight soft vibrotactile actuators are prepared as a function of the content. Experiments are conducted to examine the haptic performance of the prepared eight soft vibrotactile actuators and to find the best weight ratio of the plasticized PVC gel to the nanoparticles. The experiments should show that the plasticized PVC gel with silicon dioxide nanoparticles improves the haptic performance of the plasticized PVC gel-based vibrotactile actuator, and the proposed vibrotactile actuator can create a variety of haptic sensations in a wide frequency range.

  4. Radiation effect on PVC/ENR blends

    International Nuclear Information System (INIS)

    Chantara Thevy Ratnam; Khairul Zaman Mohd Dahlan

    1997-01-01

    The effect of irradiation on the physical properties of Polyvinyl Chloride / Epoxidised Natural Rubber Blends (PVC/ENR blends) were investigated. The enhancement in tensile strength, elongation at break, hardness and aging properties of the blends have confirmed the positive effect of irradiation on the blends. It is evident from gel fraction and infra red spectroscopic studies that the blends of PVC and ENR cross-linked upon irradiation. The results also revealed that at any blend composition, the enhancement in properties depend on irradiation dose which controls the degree of radiation induced cross-linking. In an attempt to maximize the constructive effect of irradiation, the influence of various additives such as stabilizers, radiation sensitizers, fillers and processing aids on the blend properties were studied. The changes in blend properties upon irradiation with the presents of above additives were also presented in this paper

  5. Thermal and catalytic decomposition behavior of PVC mixed plastic waste with petroleum residue

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Mohammad Farhat; Siddiqui, Mohammad Nahid [Department of Chemistry, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2005-08-15

    The pyrolysis and hydropyrolysis of PVC mixed plastic waste alone and with petroleum residue was carried out at 150 and 350{sup o}C under N{sub 2} gas and at 430{sup o}C under 6.5MPa H{sub 2} gas pressure. The behavior of plastic waste during thermal and catalytic decomposition has also been studied in single- and two-stage reaction processes. In the individual pyrolysis process, both the petroleum residue and polystyrene (PS) undergo more than 90% conversion to liquid and gaseous products, whereas low-density polyethylene (LDPE) and high-density polyethylene (HDPE) yielded lower conversions products, and polypropylene (PP) and polyvinyl chloride (PVC) afforded somewhere a moderate to high conversion products. In a single-stage pyrolysis reaction, PVC was processed with petroleum residue at 150 and 430{sup o}C, under N{sub 2} gas for 1h at each temperature in a glass reactor. The model PVC and waste PVC showed slight variations in the products distribution obtained from the glass reactor. In two-stage process, model PVC, vacuum gas oil (VGO) and a number of different catalysts were used in a stainless steel autoclave micro tubular reactor at 350{sup o}C under the stream of N{sub 2} gas for 1h and at 430{sup o}C under 950psi (6.5MPa) H{sub 2} pressure for the duration of 2h. Significantly, different products distributions were obtained. Among the catalysts used, fluid catalytic cracking (FCC) and hydrocracking catalysts (HC-1) were most effective in producing liquid fuel (hexane soluble) materials. The study shows that the catalytic coprocessing of PVC with VGO is a feasible process by which PVC and VGO materials can be converted into transportation fuels.

  6. Web Based ATM PVC Management

    NARCIS (Netherlands)

    van der Waaij, B.D.; Sprenkels, Ron; van Beijnum, Bernhard J.F.; Pras, Aiko

    1998-01-01

    This paper discusses the design of a public domain web based ATM PVC Management tool for the Dutch SURFnet research ATM network. The aim of this tool is to assists in the creation and deletion of PVCs through local and remote ATM network domains. The tool includes security mechanisms to restrict the

  7. The freestyle pedicle perforator flap

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Jackson, Ian T; Westvik, Tormod S

    2015-01-01

    BACKGROUND: Perforating vessels are a consistent anatomical finding and well described in the current literature. Any skin flap can be raised on a subcutaneous pedicle as long as it contains at least one supplying perforator. Perforator flaps have been interlinked with microsurgery and generally...... not widely performed by the general plastic surgeons. The aim of this paper is to present the simplicity of pedicled perforator flap reconstruction of moderate-sized defects of the extremities and torso. METHODS: We retrospectively reviewed the charts of 34 patients reconstructed using 34 freestyle pedicled...... perforator flaps for moderate-sized defects of the truncus and extremities. We registered indications, flap size and localization, success rate, and complications. Most importantly, we describe a simple approach to the design of freestyle pedicled perforator flaps and elaborate on technical aspects...

  8. Effect of oil extracted from coffee grounds in the radiolytic stabilization of PVC

    International Nuclear Information System (INIS)

    Lima, Thaysa Araujo de; Aquino, Katia Aparecida da Silva; Araujo, Elmo S.

    2013-01-01

    Commercial Poly(vinyl chloride) (PVC) containing oil extracted from coffee grounds (OCG) at concentrations of 0.50; 1.00 and 1.50 wt% were investigated. The samples were irradiated with gamma radiation ( 60 Co) at room temperature and air atmosphere. The viscosity-average molar mass (M v ) was measured for PVC systems without and with oil. Decreases in molar mass observed when the systems were gamma irradiated reflect the random scission effects that take place in the main chain. Degradation index (DI) value was also obtained by viscosity analysis. DI results showed that the addition of OCG at 0.5 wt% into PVC matrix irradiated at dose of 25 kGy decreased the number of main chain scissions and was calculated a protection index of 67% in PVC matrix. Results about the free radical scavenger action of the OCG were obtained by use of 2,2-diphenyl-1-(2,4,6-trinitrophenyl)-hydrazyl radical (DPPH) and are discussed in this study. Decrease of 7% of Young's modulus value and a decrease of 31.5% on the elongation at break value were recorded for PVC films exposed to gamma irradiation. However, no significant changes were recorded in mechanical properties of PVC with OCG. (author)

  9. Effect of oil extracted from coffee grounds in the radiolytic stabilization of PVC

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Thaysa Araujo de; Aquino, Katia Aparecida da Silva; Araujo, Elmo S., E-mail: aquino@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2013-07-01

    Commercial Poly(vinyl chloride) (PVC) containing oil extracted from coffee grounds (OCG) at concentrations of 0.50; 1.00 and 1.50 wt% were investigated. The samples were irradiated with gamma radiation ({sup 60}Co) at room temperature and air atmosphere. The viscosity-average molar mass (M{sub v}) was measured for PVC systems without and with oil. Decreases in molar mass observed when the systems were gamma irradiated reflect the random scission effects that take place in the main chain. Degradation index (DI) value was also obtained by viscosity analysis. DI results showed that the addition of OCG at 0.5 wt% into PVC matrix irradiated at dose of 25 kGy decreased the number of main chain scissions and was calculated a protection index of 67% in PVC matrix. Results about the free radical scavenger action of the OCG were obtained by use of 2,2-diphenyl-1-(2,4,6-trinitrophenyl)-hydrazyl radical (DPPH) and are discussed in this study. Decrease of 7% of Young's modulus value and a decrease of 31.5% on the elongation at break value were recorded for PVC films exposed to gamma irradiation. However, no significant changes were recorded in mechanical properties of PVC with OCG. (author)

  10. Photostabilizing Efficiency of PVC in the Presence of Schiff Bases as Photostabilizers

    Directory of Open Access Journals (Sweden)

    Emad Yousif

    2015-11-01

    Full Text Available The photostabilization of polyvinyl chloride (PVC films by Schiff bases was investigated. Polyvinyl chloride films containing 0.5 wt % Schiff bases were produced using the same casting method as that used for additive-free PVC films from tetrahydrofuran (THF solvent. The photostabilization activities of these compounds were determined by monitoring the carbonyl, polyene and hydroxyl indices with irradiation time. The changes in viscosity average molecular weight of PVC with irradiation time were also monitored using THF as a solvent. The quantum yield of chain scission (Φcs for the studied complexes in PVC was estimated to range between 4.72 and 8.99 × 10−8. According to the experimental results, several mechanisms were suggested, depending on the structure of the additive. Ultra violet (UV absorption, peroxide decomposition and radical scavenging were suggested as the photostabilizing mechanisms.

  11. Penelitian pengaruh asam sulfat terhadap sifat fisika kekerasan atasan sepatu kerja PVC

    Directory of Open Access Journals (Sweden)

    Kusumo Retno Winahyu

    1996-12-01

    Full Text Available The Research of hardness aspect of PVC boot upper treated by sulfuric acid to detect influence of sulfuric acid to hardness upper on PVC boot upper. The method of the research has been done by immersing samples in sulfuric acid solution 30 % (v/v for 24 hours. After immersing samples examined connected with hardness physical property. The result of the research shown that hardness physical property become decreasing until 16,08 % has error standard 5,48. It is still agree with SNI 12 – 1848-1990. Sepatu bot dari PVC.

  12. Thermal stabilisation of pvc with jatropha seed, khaya seed and rubber seed oils. Effect of barium and cadmium soaps of the seed oils on the thermal degradation of pvc

    International Nuclear Information System (INIS)

    Okieimen, F.E.

    2003-01-01

    Polyvinyl chloride was mixed with barium and cadmium soaps of Jatropha seed, Khaya seed and rubber seed oils and mixtures of the metal soaps and degraded at 190 deg. C under oxidative and non oxidative conditions. The effectiveness of the additives in stabilizing PVC against thermal degradation was evaluated by comparing (a) the kinetic data measured at 1% conversion for the degradation of PVC in the presence of the additives with the corresponding values obtained in the absence of the additives (b) the intrinsic viscosity and level of unsaturation in the polymer samples degraded for the under graded polymer and (c) the thermogravimetric data obtained for the degradation of PVC in the presence of the additives at a constant heating rate of 10 degree C min/sup -1/ up to 500 degree C. It was found that the additives retarded the rate of dehydro chlorination of PVC (by up to about 50% and 1% conversion) and reduced the extent of decomposition of the polymer by as much as 60%. The mixtures of the metal soaps containing more than 70% (wt) cadmium soap showed marked synergistic stabilizing effect on the degradation of PVC. (author)

  13. CT in acute perforated sigmoid diverticulitis

    International Nuclear Information System (INIS)

    Lohrmann, Christian; Ghanem, Nadir; Pache, Gregor; Makowiec, Frank; Kotter, Elmar; Langer, Mathias

    2005-01-01

    Background: To assess the value of computed tomography (CT) in patients with acute perforated sigmoid diverticulitis in correlation with the Hinchey classification of perforated diverticular disease. Methods: Thirty patients with acute perforated sigmoid diverticulitis underwent computed tomography prior to surgery. Computed tomography scans were compared with the surgical and histopathological reports, utilizing the Hinchey classification. Results: In 28 of the 30 (93%) patients examined, the Hinchey stage was correctly determined by means of computed tomography. One patient with Hinchey stage IV was falsely classified as Hinchey stage III, and one patient with Hinchey stage III as Hinchey stage II. Computed tomography revealed 12 out of 14 (86%) patients with perforation sites and 3 out of 3 (100%) patients with contained perforation. In one of 17 (6%) patients with surgically or histopathologically proven perforation or contained perforation, a bowel wall discontinuity was revealed by computed tomography. In 6 of the 17 (35%) patients with surgical or histopathological perforation or contained perforation, extraluminal contrast material was detected by computed tomography. Conclusions: Computed tomography is a valuable imaging tool for determining the degree of acute perforated sigmoid diverticulitis, by means of which patients can be stratified according to the severity of the disease; furthermore, this tool is of assistance in surgical planning

  14. High-Resolution Ultrasonography (US) of Appendiceal Specimens: Differentiation of Acute Non-perforated Appendicitis from Perforated Appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Gyo Chang; Kim, Suk; Im, Han Hyeok; Lee, Sang Jin; Yang, Seung Boo; Lee, Seung Woo; Kim, Il Young [Soonchunhyang University Gumi Hospital, Gumi (Korea, Republic of); Lee, Hae Kyung [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Kwon, Kui Hyang; Shin, Hyung Chul [Soonchunhyang University, College of Medicine, Seoul (Korea, Republic of)

    2007-09-15

    To analyze surgical specimens from patients with acute non-perforated and perforated appendicitis using high-resolution ultrasonography (US), and to correlate the US features with the pathologic findings. One hundred and six surgical appendix specimens obtained from patients with suspected acute appendicitis were evaluated. The following US features were evaluated for differentiating acute non-perforated appendicitis from perforated appendicitis: circumferential loss of the echogenic submucosal layer, disruption of the serosal layer, asymmetrical wall thickening, the sum of opposing walls {>=} 9 mm and the presence of appendicoliths. The sensitivity and specificity of the US findings for diagnosing perforated appendicitis were determined. All US features were detected significantly more often in the perforated appendicitis group of specimens. The disruption of the serosal layer was the most significant independent predictor of perforation (p < .001). The sensitivity for circumferential loss of the echogenic submucosal layer, disruption of the serosal layer, asymmetrical wall thickening, wall thickness {>=} 9 mm, and the presence of appendicoliths individually was 84.6%, 69.2%, 61.5%, 73.1% and 46.2%, respectively. The specificity for all of these findings was 86.3%, 98.7%, 95.0%, 85.0% and 85.0%, respectively. High-resolution US of appendiceal specimens was very useful for differentiating acute non-perforated from perforated appendicitis

  15. Management of biliary perforation in children

    Directory of Open Access Journals (Sweden)

    Mirza Bilal

    2010-01-01

    Full Text Available Background: To study the aetiology, management and outcome of biliary perforations in paediatric age group. Patients and Methods: In a retrospective study, the records of patients presented with biliary peritonitis due to biliary perforations, managed from March 2006 to July 2009, are reviewed. Results: Eight male patients with biliary peritonitis due to biliary perforation were managed. These patients were divided in two groups, A and B. Group A, (n = 3 patients, had common bile duct (CBD perforation, and Group B (n=5 patients had gallbladder perforation. The presenting features were abdominal pain, fever, abdominal distension, vomiting, constipation, jaundice and signs of peritonism. The management of CBD perforations in Group A was by draining the site of perforation and biliary diversion (tube cholecystostomy. In Group B, the gallbladder perforations were managed by tube cholecystostomy in four patients and cholecystectomy in one patient, however, one patient had to be re-explored and cholecystectomy performed due to complete necrosis of gall bladder. There was no mortality in our series. All patients were asymptomatic on regular follow-up. Conclusion: Early optimal management of biliary perforations remarkably improved the very high mortality and morbidity that characterised this condition in the past.

  16. Study of microporous PVA/PVC composite polymer membrane and it application to MnO2 capacitors

    International Nuclear Information System (INIS)

    Yang, C.-C.; Wu, G.M.

    2009-01-01

    A microporous poly(vinyl alcohol)/poly(vinyl chloride) (PVA/PVC) composite polymer membrane was successfully synthesized by a solution casting method and a preferential dissolution method. The characteristic properties of PVA/PVC composite polymer membranes were systematically studied by X-ray diffraction (XRD), scanning electron microscopy (SEM), thermal gravimetric analysis (TGA), micro-Raman spectroscopy and AC impedance spectroscopy. The PVA/PVC composite polymer membrane shows excellent thermal property, dimensional stability, and the ionic conductivity; it is due to the addition of secondary PVC polymer fillers. The MnO 2 capacitors with the PVA/PVC composite polymer membrane with 1 M Na 2 SO 4 was assembled and examined. It was found that the MnO 2 capacitor based on a microporous PVA/5 wt.%PVC composite polymer electrolyte membrane exhibited the maximum specific capacitance of 238 F g -1 and the current efficiency of 99% at 25 mV s -1 after 1000 cycle test. The result demonstrates that the novel microporous PVA/PVC composite polymer membrane is a potential candidate for use on the capacitors

  17. Preparation of modified clay with benzethonium or cetylpyridinium chloride and evaluation of their interactions with PVC

    International Nuclear Information System (INIS)

    Resende, Daniel K.; Dornelas, Camila B.; Moreira, Leonardo A.; Gomes, Ailton S.; Tavares, Maria I.B.; Cabral, Lucio M.; Simeoni, Luiz A.

    2009-01-01

    The objective of this work was the preparation of modified clays with benzethonium or cetylpyridinium to obtain organophilic silicates with good stability and evaluate the possible use of them for the preparation of nanocomposites of poly(vinyl chloride) (PVC). The reactions of modification of clays and the PVC were prepared by solution intercalation. The new clays were evaluated by X-ray diffraction (XRD) and Low field nuclear magnetic resonance (NMR). The reactions of clays with PVC were assessed by Low-field NMR, through the determination of proton spin lattice relaxation time. The stability of new organophilic clays and their reactions with PVC were evaluated by thermogravimetric analysis (TGA). High stability was observed for organophilic clays prepared. The degradation of PVC materials obtained with the organophilic clay began at temperatures above 200 deg C. If it is considered that the temperatures normally used in the processing of PVC are between 140 deg C to 180 deg C, the observed results may indicate the possibility of the use of clays for preparation of nanomaterials with PVC. (author)

  18. Estimation of life of PVC cables

    International Nuclear Information System (INIS)

    Bora, J.S.; Babar, A.K.

    1989-01-01

    Life-spans at various extrapolated temperatures corresponding to early, mid and late-stage failures of PVC are quite consistent and is about 32 years at 30degC. For every 10degC rise in ambient temperature life becomes less than half. (author). 2 tabs

  19. Early Management Experience of Perforation after ERCP

    Directory of Open Access Journals (Sweden)

    Guohua Li

    2012-01-01

    Full Text Available Background and Aim. Perforation after endoscopic retrograde cholangiopancreatography (ERCP is a rare complication, but it is associated with significant mortality. This study evaluated the early management experience of these perforations. Patients and Methods. Between November 2003 and December 2011, a total of 8504 ERCPs were performed at our regional endoscopy center. Sixteen perforations (0.45% were identified and retrospectively reviewed. Results. Nine of these 16 patients with perforations were periampullary, 3 duodenal, 1 gastric fundus, and 3 patients had a perforation of an afferent limb of a Billroth II anastomosis. All patients with perforations were recognized during ERCP by X-ray and managed immediately. One patient with duodenal perforation and three patients with afferent limb perforation received surgery, others received medical conservative treatment which included suturing lesion, endoscopic nasobiliary drainage (ENBD, endoscopic retrograde pancreatic duct drainage (ERPD, gastrointestinal decompression, fasting, broad-spectrum antibiotics, and so on. All patients with perforation recovered successfully. Conclusions. We found that: (1 the diagnosis of perforation during ERCP may be easy, but you must pay attention to it. (2 Most retroperitoneal perforations can recover with only medical conservative treatment in early phase. (3 Most peritoneal perforations need surgery unless you can close the lesion up under endoscopy in early phase.

  20. Migration of additives from poly(vinyl chloride) (PVC) tubes into aqueous media

    DEFF Research Database (Denmark)

    Wang, Qian; Storm, Birgit Kjærside

    2005-01-01

    The stability and migration product of medical PVC tubes plasticized with polyadipates were investigated by ageing in phosphate buffer at pH 1.679 and water at different temperatures. Changes in the PVC tubes were studied by wtaer absorption, weight loss, Fourier infrared spectroscopy (FTIR.......5% and only a small amount of adipic acid migrated when a tube was aged at 37 C in water and phosphate buffer (pH 1.679), and at 70 C in water after 56 days. However, when aged at 70 and 110 C, gradual deactivation of heat stabilizer after 21 days of ageing in buffer solution and separation of plasticizer...... from PVC matrix occurred. When the tube was aged at 110 C, significant degradation of both polyadipates and PVC were observed. Adipic acid and 1,4-butanediol monomers and oligomers of polyadipate were the major migration products from polyadipates in the water ageing solution, while only a relatively...

  1. The Perforation-Operation time Interval; An Important Mortality Indicator in Peptic Ulcer Perforation.

    Science.gov (United States)

    Surapaneni, Sushama; S, Rajkumar; Reddy A, Vijaya Bhaskar

    2013-05-01

    To find out the significance of the Perforation-Operation Interval (POI) with respect to an early prognosis, in patients with peritonitis which is caused by peptic ulcer perforation. Case series. Place and Duration of the Study: Department of General Surgery, Konaseema Institute of Medical Sciences and RF Amalapuram, Andhra Pradesh, India from 2008-2011. This study included 150 patients with generalized peritonitis, who were diagnosed to have Perforated Peptic Ulcers (PPUs). The diagnosis of the PPUs was established on the basis of the history , the clinical examination and the radiological findings. The perforation-operation interval was calculated from the time of onset of the symptoms like severe abdominal pain or vomiting till the time the patient was operated. Out of the 150 patients 134 were males and 16 were females, with a male : female ratio of 9:1. Their ages ranged between 25-70 years. Out of the 150 patients, 65 patients (43.3%) presented within 24 hours of the onset of severe abdominal pain (Group A), 27 patients (18%) presented between 24-48 hours of the onset of severe abdominal pain (Group B) and 58 patients (38.6%) presented after 48 hours. There was no mortality in Group A and the morbidity was more in Group B and Group C. There were 15 deaths in Group C. The problem of peptic ulcer perforation with its complication, can be decreased by decreasing the perforation -operation time interval, which as per our study, appeared to be the single most important mortality and morbidity indicator in peptic ulcer perforation.

  2. Cell Adhesion to Plasma-Coated PVC

    Directory of Open Access Journals (Sweden)

    Elidiane C. Rangel

    2014-01-01

    Full Text Available To produce environments suitable for cell culture, thin polymer films were deposited onto commercial PVC plates from radiofrequency acetylene-argon plasmas. The proportion of argon in the plasmas, PAr, was varied from 5.3 to 65.8%. The adhesion and growth of Vero cells on the coated surfaces were examined for different incubation times. Cytotoxicity tests were performed using spectroscopic methods. Carbon, O, and N were detected in all the samples using XPS. Roughness remained almost unchanged in the samples prepared with 5.3 and 28.9% but tended to increase for the films deposited with PAr between 28.9 and 55.3%. Surface free energy increased with increasing PAr, except for the sample prepared at 28.9% of Ar, which presented the least reactive surface. Cells proliferated on all the samples, including the bare PVC. Independently of the deposition condition there was no evidence of cytotoxicity, indicating the viability of such coatings for designing biocompatible devices.

  3. COMPORTAMIENTO DE UN CEMENTO ASFÁLTICO MODIFICADO CON UN DESECHO DE PVC

    Directory of Open Access Journals (Sweden)

    Fredy Alberto Reyes Lizcano

    2013-06-01

    Full Text Available Las propiedades físicas y reológicas a altas temperaturas de servicio de un cemento asfáltico (CA modificado con un desecho de policloruro de vinilo (PVC fueron evaluadas y son presentadas en el artículo. Adicionalmente se presenta la influencia del tiempo de mezcla del CA con el PVC y el envejecimiento a corto plazo. Un incremento notable en la rigidez y la resistencia a fluir se reporta cuando se adiciona el desecho de PVC a un CA 80-100. De la misma forma, se reporta un incremento en la temperatura máxima de operación en servicio del ligante modificado.

  4. Strength analysis of welded corners of PVC window profiles

    Science.gov (United States)

    Postawa, P.; Stachowiak, T.; Gnatowski, A.

    2017-08-01

    The article presents the results of researches which main purpose was to define the influence of welding parameters on strength of welded corners of PVC window profile. PVC profiles of a branded name GENEO® produced by Rehau Company were used for this research. The profiles were made by using a co-extrusion method. The surface of the profile was made of PVC mixture with no additives. Its main task was to get a smooth surface resistant to a smudge. The use of an unfilled polyester provides an aesthetic look and improves the resistance of extrudate to water getting into inner layers. The profile's inner layers have been filled up with glass fibre in order to improve its stiffness and mechanical properties. Window frames with cut corners used for this research, were produced on technological line of EUROCOLOR Company based in Pyskowice (Poland). The main goal of this analysis was to evaluate the influence of the main welding parameter (temperature upsetting) on hardness of welds we received in whole process. A universal testing machine was used for the research.

  5. High photocatalytic degradation activity of the polyvinyl chloride (PVC)-vitamin C (VC)-TiO2 nano-composite film

    International Nuclear Information System (INIS)

    Yang Changjun; Gong Chuqing; Peng Tianyou; Deng Kejian; Zan Ling

    2010-01-01

    A novel photodegradable polyvinyl chloride (PVC)-vitamin C (VC)-TiO 2 nano-composite film was prepared by embedding VC modified nano-TiO 2 photocatalyst into the commercial PVC plastic. The solid-phase photocatalytic degradation behavior of PVC-VC-TiO 2 nano-composite film under UV light irradiation was investigated and compared with those of the PVC-TiO 2 film and the pure PVC film, with the aid of UV-Vis spectroscopy, scanning electron microscopy (SEM), weight loss monitoring, and X-ray diffraction spectra (XRD). The results show that PVC-VC-TiO 2 nano-composite film has a high photocatalytic activity; the photocatalytic degradation rate of it is two times higher than that of PVC-TiO 2 film and fifteen times higher than that of pure PVC film. The optimal mass ratio of VC to TiO 2 is found to be 0.5. The mechanism of enhancing photocatalytic activity is attributed to the formation of a Ti IV -VC charge-transfer complex with five-member chelate ring structure and a rapid photogenerated charge separation is thus achieved.

  6. Preparation of Non-Woven Fiber Mats by Mixture of PVC and Epoxidized Natural Rubber

    International Nuclear Information System (INIS)

    Muhammad Hariz Othman; Mahathir Mohamed; Dahlan Mohd

    2014-01-01

    Eletrospun non-woven fibre mats prepared from ENR modified PVC were successfully fabricated at ambient temperature by electro spinning method. Liquid epoxidized natural rubber (LENR) was used because it is easier to handle compared to dried ENR. PVC was mixed with LENR based on 3 different ratios (9:1, 8:2 and 7:3). The effect of ENR on electrospinnibality of PVC was investigated.The morphologies and thermal properties of the electro span fibre mats were characterized and assessed using scanning calorimetry (DSC). The polymer solution concentration 16 aut % formed a diameter of the fibres were mainly affected by the addition of natural rubber and weight ratio of the solution. The diameter of the fibres also decreased with increasing amount of LENR in the solution. Thermal degradation involved two-step degradation with the first degradation representing the dehydro chlorination of PVC to form polyene and followed by the decomposition of LENR and the polyene.Addition of LENR into the sample caused the T g of electro spun fibre mats of PVC/LENR to shift toward lower temperature. (author)

  7. Chalk effect on PVC cross-linking under irradiation; Vliyanie mela na sshivanie PVKh pri obluchenii

    Energy Technology Data Exchange (ETDEWEB)

    Chudinova, V V; Guzeev, V V; Mozzhukhin, V B; Pomerantseva, Eh G; Nozrina, F D; Zhil` tsov, V V; Zubov, V P

    1994-12-31

    Effect of nonmodified and modified chalk on curing degree of polymer matrix was studied under-irradiation of PVC-compositions. Films of the compositions (100 mass part 7 PVC, 0-100 mas.part of chalk, 2.5 - lead sulfate, 1.5 - lead stearate and 0.3 - glycerin) were irradiated up to absorbed dose 0.1 MGy in an inert medium. Content of gel-fraction after boiling in THF was determined with use of IR spectroscopy. It was established, that intensive dehydrochlorination and polymer curing took place on chalk particle surface. Network fixed strongly chalk particles. However, chalk inhibited processes of dehydrochlorination and PVC curing, increasing amount of noncured PVC in polymer matrix.

  8. Scoring system for differentiating perforated and non-perforated pediatric appendicitis.

    Science.gov (United States)

    Blumfield, Einat; Yang, Daniel; Grossman, Joshua

    2017-10-01

    Appendicitis is the most common indication for emergency pediatric surgery and its most significant complication is perforation. Perforated appendicitis (PA) may be managed conservatively, whereas non-perforated appendicitis (NP) is managed surgically. Recent studies have shown that ultrasound (US) is effective for differentiating between PA and NP, and does not expose pediatric patients to ionizing radiation. The purpose of this study is to enhance the accuracy of differentiation with a novel scoring system based on clinical, laboratory, and US findings. This retrospective study included 243 patients aged 2-17 years who presented between 2006 and 2013 with surgically proven appendicitis, of whom 60 had perforation. Clinical and laboratory data were collected and US images evaluated by a pediatric radiologist. To create the scoring system, point values were assigned to each parameter. A randomly selected training sample of 137 subjects was used to create a scoring prediction model. The model was tested on the remaining 106 patients. Scores of ≥6, ≥11, and ≥15 yielded specificities of 64, 91, and 99%, and sensitivities of 96, 61, and 29%, respectively (p < 0.001). We have designed a scoring system incorporating clinical, laboratory, and sonographic findings which can differentiate PA from NP with high specificity.

  9. Effect of PVC on ionic conductivity, crystallographic structural, morphological and thermal characterizations in PMMA-PVC blend-based polymer electrolytes

    International Nuclear Information System (INIS)

    Ramesh, S.; Liew, Chiam-Wen; Morris, Ezra; Durairaj, R.

    2010-01-01

    In this paper, temperature dependence of ionic conductivity, crystallographic structural, morphological and thermal characteristics of polymer blends of PMMA and PVC with lithium bis(trifluoromethanesulfonyl) imide (LiTFSI) as a dopant salt are investigated. The study on the temperature dependence of ionic conductivity shows that these polymer blends exhibit Arrhenius behavior. The highest ionic conductivity was achieved when 70 wt% of PMMA was blended with 30 wt% of PVC. X-ray diffraction (XRD) and scanning electron microscopy (SEM) reveal the amorphous nature and surface morphology of polymer electrolytes, respectively. In DSC analysis it was found that the glass transition temperature (T g ) and melting temperature (T m ) decreased, whereas the decomposition temperature (T d ) increased. In contrast, the shift towards higher decomposition temperature and decrease in weight loss of polymer electrolytes, in TGA studies, indicates that the thermal stability of polymer electrolytes improved.

  10. Dimensional changes of alginate impression by using perforated and non-perforated ring trays

    Directory of Open Access Journals (Sweden)

    Sumadhi Sastrodihardjo

    2010-03-01

    Full Text Available Dimensional changes are a common occurrence in impressions, either during or after impression taking. It produces a difference in the dimensions of the object and the model, which leads to the restoration being ill-fitted. Several causal factors have been proposed such as friction between the impression material and the teeth, the bulk of the impression material, the type of impression materials used, the impression technique, the pouring time and many others. The exact causal factor is still unknown and the dimensional change mechanism is still poorly understood. The objective of this research was to investigate the role of the perforation on the ring trays in producing dimensional changes in the impression by using perforated and non-perforated ring trays. Alginate impressions were made on the frustum of cone metal master die with a 7.08 mm base diameter, 7.03 mm top diameter and 9.23 mm height using perforated and non-perforated ring trays with 9.40 mm in diameter and 14.17 mm in height. The dimensional change was determined by comparing the dimension of the dental stone die and its metal master die. The results showed that the percentage of dimensional changes that occurred by using perforated ring tray were (+ 0.56±0.40 on the top area, (- 3.54±2.92 on base area and (+ 1.54±0.83 in height, respectively. As compared to using non-perforated ring trays, the percentage of dimensional changes that occurred were (- 0.49±0.49 on top area, (- 8.76±3.95 on base area and (+ 1.19±0.71 in height, respectively. There was a significant difference in the direction of the dimensional changes on both the top areas, but not in the base areas and height.

  11. Dose Rate Effect on Grafting by Gamma Radiation of DMAEMA onto Flexible PVC

    International Nuclear Information System (INIS)

    Panzarini, L.C.G.A.; Araujo, F.D.C.; Martinello, V.C.; Somesari, E.; Manzoli, J.E.; Silveira, C.; Paes, H.A.; Moura, E.

    2009-01-01

    Intravenous tubing, blood bags and catheters stays in contact with blood and body fluids. They are normally made by flexible PVC. The contact of PVC with this fluid is not possible for long periods and there is the necessity of addition of non-thrombogenic substances into blood. This work shows the radiation grafting process to produce copolymer PVC-g-DMAEMA, a new material that allows a future grafting of Heparin on it, and will have the perspective of avoiding undesirable substances additions to blood or body fluid contact. In this preliminary work, only radiation dose rate effect on grafting was studied

  12. D-FNN Based Modeling and BP Neural Network Decoupling Control of PVC Stripping Process

    Directory of Open Access Journals (Sweden)

    Shu-zhi Gao

    2014-01-01

    Full Text Available PVC stripping process is a kind of complicated industrial process with characteristics of highly nonlinear and time varying. Aiming at the problem of establishing the accurate mathematics model due to the multivariable coupling and big time delay, the dynamic fuzzy neural network (D-FNN is adopted to establish the PVC stripping process model based on the actual process operation datum. Then, the PVC stripping process is decoupled by the distributed neural network decoupling module to obtain two single-input-single-output (SISO subsystems (slurry flow to top tower temperature and steam flow to bottom tower temperature. Finally, the PID controller based on BP neural networks is used to control the decoupled PVC stripper system. Simulation results show the effectiveness of the proposed integrated intelligent control method.

  13. Fate of free chlorine in drinking water during distribution in premise plumbing.

    Science.gov (United States)

    Zheng, Muzi; He, Chunguang; He, Qiang

    2015-12-01

    Free chlorine is a potent oxidizing agent and has been used extensively as a disinfectant in processes including water treatment. The presence of free chlorine residual is essential for the prevention of microbial regrowth in water distribution systems. However, excessive levels of free chlorine can cause adverse health effects. It is a major challenge to maintain appropriate levels of free chlorine residual in premise plumbing. As the first effort to assessing the fate of chlorine in premise plumbing using actual premise plumbing pipe sections, three piping materials frequently used in premise plumbing, i.e. copper, galvanized iron, and polyvinyl chloride (PVC), were investigated for their performance in maintaining free chlorine residual. Free chlorine decay was shown to follow first-order kinetics for all three pipe materials tested. The most rapid chlorine decay was observed in copper pipes, suggesting the need for higher chlorine dosage to maintain appropriate levels of free chlorine residual if copper piping is used. PVC pipes exhibited the least reactivity with free chlorine, indicative of the advantage of PVC as a premise plumbing material for maintaining free chlorine residual. The reactivity of copper piping with free chlorine was significantly hindered by the accumulation of pipe deposits. In contrast, the impact on chlorine decay by pipe deposits was not significant in galvanized iron and PVC pipes. Findings in this study are of great importance for the development of effective strategies for the control of free chlorine residual and prevention of microbiological contamination in premise plumbing.

  14. Delta neutrophil index: A reliable marker to differentiate perforated appendicitis from non-perforated appendicitis in the elderly.

    Science.gov (United States)

    Shin, Dong Hyuk; Cho, Young Suk; Kim, Yoon Sung; Ahn, Hee Cheol; Oh, Young Taeck; Park, Sang O; Won, Moo-Ho; Cho, Jun Hwi; Kim, Young Myeong; Seo, Jeong Yeol; Lee, Young Hwan

    2018-01-01

    Delta neutrophil index (DNI) is a new inflammatory marker and the present study aimed to evaluate the predictive value of the DNI for the presence of a perforation in elderly with acute appendicitis. This retrospective observational study was conducted on 108 consecutive elderly patients (≥65 years old) with acute appendicitis treated over a 24-month period. Sixty-nine of the 108 patients (median, IQR: 72, 67-77 years) were allocated to the perforated appendicitis group (63.9%) and 39 to the non-perforated appendicitis group (36.1%). WBC, neutrophil-to-lymphocyte ratio, platelet-to-lymphocyte ratio and DNI were significantly higher in the perforated group. In multiple logistic regression analyses, initial DNI was the only independent marker that can significantly predict the presence of perforation in multiple regression [odds ratio 9.38, 95% confidence interval (2.51-35.00), P=.001]. Receiver operator characteristic curve analysis showed that DNI is a good predictor for the presence of appendiceal perforation at an optimal cut-off for DNI being 1.4% (sensitivity 67.7%, specificity 90.0%, AUC 0.807). Clinicians can reliably differentiate acute perforated appendicitis from non-perforated appendicitis by DNI level of 1.4 or more in elderly patients. © 2017 Wiley Periodicals, Inc.

  15. Influência do tipo de agente de partição da borracha nitrílica na obtenção de blendas PVC/NBR Influence of the partitioning agent on the preparation of PVC/NBR Blends

    Directory of Open Access Journals (Sweden)

    Fábio R. Passador

    2008-09-01

    Full Text Available Borrachas nitrílicas para utilização em misturas com PVC são fornecidas em forma de pó, que são recobertas com um agente de partição para evitar compactação do produto no transporte e armazenamento, além de garantir alta fluidez e livre escoamento. Neste trabalho, buscou-se estudar a influência do tipo de agente de partição da borracha nitrílica (resina de PVC e CaCO3 na obtenção de blendas PVC/NBR. As propriedades mecânicas das blendas foram avaliadas por ensaios de tração, rasgo e dureza. As blendas com NBR com agente de partição de PVC apresentaram maior tensão na ruptura e módulo elástico que as blendas em que utilizaram NBR com agente de partição de CaCO3. A morfologia foi avaliada por microscopia eletrônica de varredura sendo bastante afetada pelo tipo de agente de partição.Nitrile rubbers used in mixture with PVC resin are supplied in powder. This kind of nitrile rubber has a partitioning agent to avoid agglomeration in the particles during the transport and storage. In this study, the influence of the partitioning agent on the preparation of PVC/NBR blends was investigated. The mechanical properties of the blends were evaluated by tensile properties, tear strength and hardness. The PVC/NBR blends with partitioning agent of PVC showed an increase in the tensile stress and Young's modulus compared to the PVC/NBR blends with partitioning agent of CaCO3. The morphology of the blends examined by scanning electron microscopy demonstrated the influence of the partitioning agent.

  16. CT findings of exophageal perforation

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Jeong Nam; Choi, Yo Won; Jeon, Seok Chol; Park, Choong Ki; Hahm, Chang Kok [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2002-09-01

    To determine which CT findings are useful for the early disgnosis of esophageal perforation, and on the basis of these findings, to assess the accuracy of prediction of the perforation site. A review of medical records indicated that between January 1995 and December 2001, 36 patients with esophageal perforation were admitted to our hospital. Thirteen of these [M:F=8:5, age; 28-69 (mean, 52.4) years], who had undergone CT chest scanning, were included in this study. The causes of esophageal perforation were trauma (n=5), infectious diseases (n=4), Boerhaave syndrome (n=1), lung cancer (n=1), esophageal cancer (n=1), and idiopathic. Two chest radiologists unaware of the clinical findings reviewed the CT scans and predicted whether the upper or lower esophagus was perforated. The most common CT finding was extraluminal air at the posterior mediastinum (n=11), while other findings included pulmonary consolidation (n=10), pleural effusion (n=7), discontinuity of the esophageal wall (n=6) and subcutaneous emphysema (n=4), fluid collection around the esophagus (n-4), esophageal wall thickening (n=4), pneumothorax (n=2), and lung abscess (n=2). The perforation site was accurately predicted in 76.9% of cases (10/13). The CT findings which help the diagnosis of esophageal perforation, and prediction of the sites at which it occurs, are extraluminal air of fluid collection, focal defect of the esophageal wall, and esophageal wall thickening.

  17. CT findings of exophageal perforation

    International Nuclear Information System (INIS)

    Heo, Jeong Nam; Choi, Yo Won; Jeon, Seok Chol; Park, Choong Ki; Hahm, Chang Kok

    2002-01-01

    To determine which CT findings are useful for the early disgnosis of esophageal perforation, and on the basis of these findings, to assess the accuracy of prediction of the perforation site. A review of medical records indicated that between January 1995 and December 2001, 36 patients with esophageal perforation were admitted to our hospital. Thirteen of these [M:F=8:5, age; 28-69 (mean, 52.4) years], who had undergone CT chest scanning, were included in this study. The causes of esophageal perforation were trauma (n=5), infectious diseases (n=4), Boerhaave syndrome (n=1), lung cancer (n=1), esophageal cancer (n=1), and idiopathic. Two chest radiologists unaware of the clinical findings reviewed the CT scans and predicted whether the upper or lower esophagus was perforated. The most common CT finding was extraluminal air at the posterior mediastinum (n=11), while other findings included pulmonary consolidation (n=10), pleural effusion (n=7), discontinuity of the esophageal wall (n=6) and subcutaneous emphysema (n=4), fluid collection around the esophagus (n-4), esophageal wall thickening (n=4), pneumothorax (n=2), and lung abscess (n=2). The perforation site was accurately predicted in 76.9% of cases (10/13). The CT findings which help the diagnosis of esophageal perforation, and prediction of the sites at which it occurs, are extraluminal air of fluid collection, focal defect of the esophageal wall, and esophageal wall thickening

  18. Current management of peptic ulcer perforations

    International Nuclear Information System (INIS)

    Menakuru, S.R.

    2004-01-01

    Perforation is a life-threatening complication of peptic ulcer disease. Smoking and use of non-steroidal anti-inflammatory drugs are important risk factors for perforation. Diagnosis is made clinically and confirmed by the presence of pneumoperitoneum on radiographs. Nonoperative management is successful in patients identified to have a spontaneously sealed perforation proven by water-soluble contrast gastroduodenogram. Operative management consists of the time-honoured practice of mental patch closure, but now this can be done by laparoscopic methods. The practice of addition of acid-reducing procedures is currently being debated though it continues to be recommended in good-risk patients. Laparoscopic approaches to closure of duodenal perforation are now being applied widely and may become the gold standard in the future especially in patients with < 10 mm perforation size presenting within the first 24 hours of onset of pain. The role of Helicobacter pylori in duodenal ulcer perforation is controversial and more studies are needed to answer this question though recent indirect evidence suggests that eradicating H pylori may reduce the necessity for adding acid reducing procedures and the associated morbidity. Perforation is a life-threatening complication of peptic ulcer disease. The management of peptic ulcer disease has evolved over the decades, due to advances in operative techniques, bacteriology and pharmacology. While the recognition of the role of Helicobacter pylori (H. pylori) in peptic ulceration has resulted in a paradigm shift in the management of uncomplicated peptic ulcers, debate continues about the appropriate management of perforated duodenal bulb and prepyloric ulcers. A new dimension has been added to this controversy by the advent of laparoscopic techniques for closing the perforation. A Medline search of all articles dealing with the management of peptic ulcer perforation published after 1985 was undertaken. The short listed articles were

  19. The pvc operon regulates the expression of the Pseudomonas aeruginosa fimbrial chaperone/usher pathway (cup genes.

    Directory of Open Access Journals (Sweden)

    Uzma Qaisar

    Full Text Available The Pseudomonas aeruginosa fimbrial structures encoded by the cup gene clusters (cupB and cupC contribute to its attachment to abiotic surfaces and biofilm formation. The P. aeruginosa pvcABCD gene cluster encodes enzymes that synthesize a novel isonitrile functionalized cumarin, paerucumarin. Paerucumarin has already been characterized chemically, but this is the first report elucidating its role in bacterial biology. We examined the relationship between the pvc operon and the cup gene clusters in the P. aeruginosa strain MPAO1. Mutations within the pvc genes compromised biofilm development and significantly reduced the expression of cupB1-6 and cupC1-3, as well as different genes of the cupB/cupC two-component regulatory systems, roc1/roc2. Adjacent to pvc is the transcriptional regulator ptxR. A ptxR mutation in MPAO1 significantly reduced the expression of the pvc genes, the cupB/cupC genes, and the roc1/roc2 genes. Overexpression of the intact chromosomally-encoded pvc operon by a ptxR plasmid significantly enhanced cupB2, cupC2, rocS1, and rocS2 expression and biofilm development. Exogenously added paerucumarin significantly increased the expression of cupB2, cupC2, rocS1 and rocS2 in the pvcA mutant. Our results suggest that pvc influences P. aeruginosa biofilm development through the cup gene clusters in a pathway that involves paerucumarin, PtxR, and different cup regulators.

  20. Glove Perforations During Interventional Radiological Procedures

    International Nuclear Information System (INIS)

    Leena, R. V.; Shyamkumar, N. K.

    2010-01-01

    Intact surgical gloves are essential to avoid contact with blood and other body fluids. The objective of this study was to estimate the incidence of glove perforations during interventional radiological procedures. In this study, a total of 758 gloves used in 94 interventional radiological procedures were examined for perforations. Eleven perforations were encountered, only one of which was of occult type. No significant difference in the frequency of glove perforation was found between the categories with varying time duration.

  1. Enhanced Design of a Soft Thin-Film Vibrotactile Actuator Based on PVC Gel

    Directory of Open Access Journals (Sweden)

    Won-Hyeong Park

    2017-09-01

    Full Text Available We fabricated a soft thin-film vibrotactile actuator, which can be easily inserted into wearable devices, based on an electroactive PVC gel. One of the most important factors in fabricating a soft and thin vibrotactile actuator is to create vibrational force strong enough to stimulate human skin in a wide frequency range. To achieve this, we investigate the working principle of the PVC gel and suggest a new structure in which most of electric energy contributes to the deformation of the PVC gel. Due to this structure, the vibrational amplitude of the proposed PVC gel actuator could considerably increase (0.816 g (g = 9.8 m/s2 at resonant frequency. The vibrotactile amplitude is proportional to the amount of input voltage. It increased from 0.05 g up to 0.416 g with increasing applied voltages from 200 V to 1 kV at 1 Hz. The experimental results show that the proposed actuator can create a variety of haptic sensations.

  2. Helicobacter pylori in gastroduodenal perforation

    Directory of Open Access Journals (Sweden)

    Bharat B Dogra

    2014-01-01

    Full Text Available Background:peptic ulcers were earlier believed to be caused by dietary factors, gastric acid, and stress. However, in 1983, Warren and Marshall identified the correlation between Helicobacter pylori (H. pylori and peptic ulcers. It is now well established that most of the peptic ulcers occur as a result of H. pylori infection. But the co-relation between perforated peptic ulcer and H. pylori infection is not yet fully established. Aims and objectives : to study the prevalence of H. pylori infection in patients with perforated peptic ulcer. Materials and methods: this was a prospective study carried out in all cases of perforated peptic ulcer reporting in surgical wards of a medical college during 2008-2010. A total of 50 cases, presenting as acute perforation of duodenum and stomach during this period, formed the study group. After resuscitation, all the cases were subjected to emergency exploratory laparotomy. The exact site of perforation was identified, biopsy was taken from the ulcer margin from 2-3 sites and the tissue was sent for H. pylori culture and histopathological examination. Simple closure of perforation, omentoplasty, thorough peritoneal lavage and drainage was carried out. Results: out of the 50 cases of perforated peptic ulcer, 38 happened to be males, and only 12 were females. The age of the patients ranged from 20 to 70 years. All the patients underwent only emergency laparotomy. As many as 46 cases (92% turned out to be positive for H. pylori and only four cases (8% were negative for this infection. Postoperatively, patients who were found to be positive for H. pylori were put on anti-H. pylori treatment. Conclusion: there was a high prevalence of H. pylori infection in patients with perforated gastroduodenal ulcers.

  3. Spectrum of perforation peritonitis in delhi: 77 cases experience.

    Science.gov (United States)

    Yadav, Dinesh; Garg, Puneet K

    2013-04-01

    Perforation peritonitis is the most common surgical emergency encountered by surgeons all over the world as well in India. The spectrum of etiology of perforation peritonitis in tropical countries continues to differ from its western counterpart. This study was conducted at Hindu Rao Hospital, Municipal Corporation of Delhi, New Delhi, India, designed to highlight the spectrum of perforation peritonitis in the eastern countries and to improve its outcome. This prospective study included 77 consecutive patients of perforation peritonitis studied in terms of clinical presentations, causes, site of perforation, surgical treatment, postoperative complications, and mortality at Hindu Rao Hospital, Delhi, from March 1, 2011 to December 1, 2011, over a period of 8 months. All patients were resuscitated and underwent emergency exploratory laparotomy. On laparotomy cause of perforation peritonitis was found and controlled. The most common cause of perforation peritonitis noticed in our series was perforated duodenal ulcer (26.4 %) and ileal typhoid perforation (26.4 %), each followed by small bowel tuberculosis (10.3 %) and stomach perforation (9.2 %), perforation due to acute appendicitis (5 %). The highest number of perforations was seen in ileum (39.1 %), duodenum (26.4 %), stomach (11.5 %), appendix (3.5 %), jejunum (4.6 %), and colon (3.5 %). Overall mortality was 13 %. The spectrum of perforation peritonitis in India continuously differs from western countries. The highest number of perforations was noticed in the upper part of the gastrointestinal tract as compared to the western countries where the perforations seen mostly in the distal part. The most common cause of perforation peritonitis was perforated duodenal ulcer and small bowel typhoid perforation followed by typhoid perforation. Large bowel perforations and malignant perforations were least common in our setup.

  4. PVC posting bags for glove boxes

    International Nuclear Information System (INIS)

    1976-12-01

    This specification covers the materials, measurements and manufacture of unpigmented PVC posting bags for use on glove boxes, together with methods of testing the materials. These bags are used in the handling of radioactive and toxic materials of a hazardous nature and therefore must be of the highest standard of mechanical strength, leak tightness and general finish. (author)

  5. Effect of Modified Natural Rubber on PVC-ENR Electrospun Membrane: Thermal and Morphological Studies

    International Nuclear Information System (INIS)

    Mahathir Mohamed; Dahlan Mohd; Ratnam, C.T.; Pairu Ibrahim

    2016-01-01

    Electrospun fibers membrane (EFM) based on modified epoxidized natural rubber (ENR) and polyvinyl chloride (PVC) was successfully prepared by electro spinning technique. Epoxidized natural rubber was firstly prepared in solution by using 5 L flask and exposed to high intensity UV lamp for degradation. The PVC/ ENR mixture solution concentration were about 16 wt% and blended for 5 hours for homogeneity. The PVC/ ENR mixture were electro spun to form fibers membrane. The sample of electro spun fibers membrane were cured by electron beam. The resulting membranes were characterized for thermal and morphological studies. Thermal decomposition behavior of EFM was analyzed by thermogravimetric analysis (TGA). Thermo gram from TGA showed two stages of degradation for all formulation (90:10, 80:20, 70:30 PVC/ ENR) from 240 to 265 degree Celsius and 400 to 410 degree Celsius, respectively. From the DSC thermo gram of PVC/ ENR electro spun fibers showed that the addition of ENR resulted in the shifting of glass transition temperature (Tg) towards lower temperatures. The morphology of electro spun fibers was examined using scanning electron microscopy and it showed a variety of fiber morphologies. (author)

  6. The management of large perforations of duodenal ulcers

    Directory of Open Access Journals (Sweden)

    Sharma Rajeev

    2005-06-01

    Full Text Available Abstract Background Duodenal ulcer perforations are a common surgical emergency, but literature is silent on the exact definition, incidence, management and complications of large perforations of duodenal ulcers. Methods The case files of 162 patients who underwent emergency laparotomy for duodenal ulcer perforations over a period of three years (2001 – 2003 were retrospectively reviewed and sorted into groups based on the size of the perforations – one group was defined as 'small 'perforations (less than 1 cm in diameter, another 'large' (when the perforation was more than 1 cm but less than 3 cms, and the third, 'giant'(when the perforation exceeded 3 cm. These groups of patients were then compared with each other in regard to the patient particulars, duration of symptoms, surgery performed and the outcome. Results A total of 40 patients were identified to have duodenal ulcer perforations more than 1 cm in size, thus accounting for nearly 25 % of all duodenal ulcer perforations operated during this period. These patients had a significantly higher incidence of leak, morbidity and mortality when compared to those with smaller perforations. Conclusion There are three distinct types of perforations of duodenal ulcers that are encountered in clinical practice. The first, are the 'small' perforations that are easy to manage and have low morbidity and mortality. The second are the 'large' perforations, that are also not uncommon, and omental patch closure gives the best results even in this subset of patients. The word 'giant' should be reserved for perforations that exceed 3 cms in diameter, and these are extremely uncommon.

  7. Vida útil e metabolismo de carboidratos em raízes de mandioquinha-salsa sob refrigeração e filme de PVC Shelf life and carbohydrate metabolism of arracacha roots stored under refrigeration and PVC film

    Directory of Open Access Journals (Sweden)

    Rosilene Antonio Ribeiro

    2007-04-01

    Full Text Available O objetivo deste trabalho foi avaliar a influência da temperatura de armazenamento e do uso do filme de cloreto de polivinila (PVC sobre a perda de matéria fresca e água, incidência de danos causados por frio e metabolismo pós-colheita dos carboidratos, em raízes tuberosas de mandioquinha-salsa (Arracacia xanthorrhiza. O filme de PVC reduziu a perda de matéria fresca e manteve o teor de água das raízes, durante o armazenamento por 60 dias a 5 e 10ºC. Os danos causados por frio foram inibidos nas raízes embaladas em filme de PCV, em ambas as temperaturas de armazenamento. As baixas temperaturas induziram o acúmulo de açúcares solúveis e a degradação de amido e, para as raízes armazenadas sem PVC, o aumento do conteúdo dos açúcares solúveis foi transiente e a taxa de degradação de amido foi superior à das raízes armazenadas com PVC.The objective of this work was to evaluate the influence of the storage temperature and stretch polyvinylchloride (PVC film on the loss of fresh weight and water, on the development of chilling injury symptoms, and on the postharvest metabolism of carbohydrates, in arracacha tuber roots (Arracacia xanthorrhiza. The PVC film reduced the fresh weight loss and kept water content in the roots during 60-day storage period at 5 and 10ºC. PVC film in both storage temperatures inhibited the development of external and internal chilling injury symptoms. The low temperatures induced the increase of soluble sugar content and decrease of starch concentration, where the increase in soluble sugar was transient in roots stored without PVC film, and the rate of starch degradation was higher compared to the roots stored with PVC.

  8. Effect of PVC on ionic conductivity, crystallographic structural, morphological and thermal characterizations in PMMA-PVC blend-based polymer electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Ramesh, S., E-mail: rameshtsubra@gmail.com [Centre for Ionics University Malaya, Department of Physics, Faculty of Science, University of Malaya, Lembah Pantai, 50603 Kuala Lumpur (Malaysia); Liew, Chiam-Wen; Morris, Ezra; Durairaj, R. [Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Setapak, 53300 Kuala Lumpur (Malaysia)

    2010-11-20

    In this paper, temperature dependence of ionic conductivity, crystallographic structural, morphological and thermal characteristics of polymer blends of PMMA and PVC with lithium bis(trifluoromethanesulfonyl) imide (LiTFSI) as a dopant salt are investigated. The study on the temperature dependence of ionic conductivity shows that these polymer blends exhibit Arrhenius behavior. The highest ionic conductivity was achieved when 70 wt% of PMMA was blended with 30 wt% of PVC. X-ray diffraction (XRD) and scanning electron microscopy (SEM) reveal the amorphous nature and surface morphology of polymer electrolytes, respectively. In DSC analysis it was found that the glass transition temperature (T{sub g}) and melting temperature (T{sub m}) decreased, whereas the decomposition temperature (T{sub d}) increased. In contrast, the shift towards higher decomposition temperature and decrease in weight loss of polymer electrolytes, in TGA studies, indicates that the thermal stability of polymer electrolytes improved.

  9. Laparoscopic pyloroplasty for perforated peptic ulcer.

    Science.gov (United States)

    Grišin, Edvard; Mikalauskas, Saulius; Poškus, Tomas; Jotautas, Valdemaras; Strupas, Kęstutis

    2017-09-01

    Peptic ulcer is a common disease affecting millions of people every year. Despite improved understanding and treatment of the disease, the number of patients admitted with duodenal peptic ulcer perforation has not decreased. Deaths from peptic ulcer disease overcome other common emergency situations. Laparoscopic repair of the perforated peptic ulcer (PPU) is the gold standard approach for simple perforation. However, in patients with large perforated chronic ulcers laparotomy with pyloroplasty is the standard treatment. It is generally accepted to perform open surgery in PPU emergencies because of the greater knowledge and experience gathered over the past decades and less potential harm for the patient or surgical complications. We present a case of successful laparoscopic pyloroplasty of a perforated duodenal ulcer with stenosis.

  10. Electroless plating of PVC plastic through new surface modification method applying a semi-IPN hydrogel film

    International Nuclear Information System (INIS)

    Wang, Ming-Qiu; Yan, Jun; Du, Shi-Guo; Li, Hong-Guang

    2013-01-01

    A novel palladium-free surface activation process for electroless nickel plating was developed. This method applied a semi-Interpenetrating Polymer Network (semi-IPN) hydrogel film to modify the poly(vinyl chloride) (PVC) surface by chemical bonds. The activation process involved the formation of semi-IPN hydrogel film on the PVC surface and the immobilization of catalyst for electroless plating linking to the pretreated substrate via N-Ni chemical bond. The hydrogel layer was used as the chemisorption sites for nickel ions, and the catalyst could initiate the subsequent electroless nickel plating onto the PVC surface. Finally, a Ni–P layer was deposited on the nickel-activated PVC substrate by electroless plating technique. The composition and morphology of nickel-plated PVC foils were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). The results of SEM and XRD show that a compact and continuous Ni–P layer with amorphous nickel phase is formed on the PVC surface. EDS shows that the content of the nickel and the phosphorus in the deposits is 89.4 wt.% and 10.6 wt.%, respectively.

  11. Electroless plating of PVC plastic through new surface modification method applying a semi-IPN hydrogel film

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ming-Qiu, E-mail: mqwang1514@163.com; Yan, Jun; Du, Shi-Guo; Li, Hong-Guang

    2013-07-15

    A novel palladium-free surface activation process for electroless nickel plating was developed. This method applied a semi-Interpenetrating Polymer Network (semi-IPN) hydrogel film to modify the poly(vinyl chloride) (PVC) surface by chemical bonds. The activation process involved the formation of semi-IPN hydrogel film on the PVC surface and the immobilization of catalyst for electroless plating linking to the pretreated substrate via N-Ni chemical bond. The hydrogel layer was used as the chemisorption sites for nickel ions, and the catalyst could initiate the subsequent electroless nickel plating onto the PVC surface. Finally, a Ni–P layer was deposited on the nickel-activated PVC substrate by electroless plating technique. The composition and morphology of nickel-plated PVC foils were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). The results of SEM and XRD show that a compact and continuous Ni–P layer with amorphous nickel phase is formed on the PVC surface. EDS shows that the content of the nickel and the phosphorus in the deposits is 89.4 wt.% and 10.6 wt.%, respectively.

  12. Electroless plating of PVC plastic through new surface modification method applying a semi-IPN hydrogel film

    Science.gov (United States)

    Wang, Ming-Qiu; Yan, Jun; Du, Shi-Guo; Li, Hong-Guang

    2013-07-01

    A novel palladium-free surface activation process for electroless nickel plating was developed. This method applied a semi-Interpenetrating Polymer Network (semi-IPN) hydrogel film to modify the poly(vinyl chloride) (PVC) surface by chemical bonds. The activation process involved the formation of semi-IPN hydrogel film on the PVC surface and the immobilization of catalyst for electroless plating linking to the pretreated substrate via Nsbnd Ni chemical bond. The hydrogel layer was used as the chemisorption sites for nickel ions, and the catalyst could initiate the subsequent electroless nickel plating onto the PVC surface. Finally, a Ni-P layer was deposited on the nickel-activated PVC substrate by electroless plating technique. The composition and morphology of nickel-plated PVC foils were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). The results of SEM and XRD show that a compact and continuous Ni-P layer with amorphous nickel phase is formed on the PVC surface. EDS shows that the content of the nickel and the phosphorus in the deposits is 89.4 wt.% and 10.6 wt.%, respectively.

  13. Degradation behavior of PVC film in aqueous solution at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Shun-Myung; Kim, Jong-Hwa; Lee, Soo [Changwon National University, Changwon(Korea)

    2001-02-28

    The heat treatment of PVC film containing PVC 65%, DOP (Dioctyl Phthalate) 32% as plasticizer, Ca-Zn stearates and surface agent was performed under several conditions to study the dehydrochlorination of PVC and char production. In the case of H{sub 2}SO{sub 4}, the dehydrochlorination was ca.100% at 250 deg.C for 3h. The char involving the smaller pores was produced with hydrothermal treatment. The pore size became small with increasing the treatment time and temperature. In the case of treatment with Ca(OH){sub 2}, the sizes of pores produced in char were about sever {approx}10 {mu}m at 225 deg.C for 12h. In the case of H{sub 2}SO{sub 4}, the size of pores were about 1 {mu}m in 5M H{sub 2}SO{sub 4} for 12h. (author). 6 refs., 3 tabs., 11 figs.

  14. CLINICAL STUDY OF DUODENAL PERFORATION

    Directory of Open Access Journals (Sweden)

    Sambasiva Rao

    2016-04-01

    Full Text Available BACKGROUND The duodenal injury can pose a formidable challenge to the surgeon and failure to manage it properly may have devastating results. Over the centuries, there was little to offer the patient of acute abdomen beyond cupping, purgation and enemas, all of which did more harm than good. It was not until 1884 that Mikulicz made an attempt to repair a perforation. Recent statistics indicate roughly 10% of population develop gastric or duodenal ulcer in life time. Roughly 1-3% of population above the age of 20 years have some degree of peptic ulcer activity during any annual period. A detailed history with regards to the signs and symptoms of the patient, a meticulous examination, radiological and biochemical investigations help to arrive at a correct preoperative diagnosis. In this study, a sincere effort has been put to understand the demographic patterns, to understand the underlying aetiology and to understand the effectiveness of the standard methods of investigation and treatment in use today. METHODS This is a 24 months prospective study i.e., from September 2011 to September 2013 carried out at Dr. Pinnamaneni Siddhartha Institute of Medical Sciences & Research Foundation. The study included the patients presenting to Dr. Pinnamaneni Siddhartha Institute of Medical Sciences & Research Foundation to emergency ward with signs and symptoms of hollow viscus perforation. The sample size included 30 cases of duodenal perforation. RESULTS Duodenal ulcer perforation commonly occurs in the age group of 30-60 years, but it can occur in any age group. Majority of the patients were male. Smoking and alcohol consumption were risk factors in most cases (53.3% for the causation of duodenal ulcer perforation. Sudden onset of abdominal pain, situated at epigastrium and right hypochondrium was a constant symptom (100%. Vomiting, constipation and fever were not so common. CONCLUSION The emergency surgical management for perforated duodenal ulcer is by

  15. The 1st EMBO workshop on PVC bacteria-Planctomycetes-Verrucomicrobia-Chlamydiae superphylum: exceptions to the bacterial definition?

    Science.gov (United States)

    Devos, Damien P; Jogler, Christian; Fuerst, John A

    2013-10-01

    The PVC superphylum is a phylogenetically supported collection of various related bacterial phyla that comprise unusual characteristics and traits. The 'PVC' abbreviation derives from Planctomycetes, Verrucomicrobia and Chlamydiae as members of this superphylum, while additional bacterial phyla are related. There has recently been increasing and exciting interest in the cell biology, physiology and ecology of members of this superphylum, including evolutionary implications of the complex cell organization of some species. It is timely that international researchers in the PVC superphylum field met to discuss these developments. The first meeting entirely dedicated to those bacteria, the EMBO workshop "PVC superphylum: Exceptions to the bacterial definition" was held at the Heidelberg University to catalyze the formation of a vital scientific community supporting PVC-bacterial research. More than 45 investigators from more than 20 countries (PIs, senior scientists and students) attended the meeting and produced a great starting point for future collaborative research. This Special Issue will focus on the EMBO-PVC meeting. This Perspective briefly summarizes the history of PVC-research, focusing on the key findings and provides a brief summary of the meeting with a focus on the major questions that arose during discussion and that might influence the research in the years to come.

  16. A perforated diverticulum in Cushing's disease

    OpenAIRE

    de Havenon, Adam; Ehrenkranz, Joel

    2011-01-01

    We report a case of perforated colonic diverticulum in Cushing's disease. Although perforated diverticuli have been described in patients with Cushing's syndrome secondary to exogenous glucocorticoids, this complication has not been described in patients with Cushing's disease. Patients with hypercortisolism, from either exogenous or endogenous sources, should be monitored for diverticular perforation.

  17. Synthesis of AzPhchitosan-bifenthrin-PVC to protect cables against termites.

    Science.gov (United States)

    Zhang, Lingkun; Cai, Weiwei; Chen, Wu-Ya; Zhang, Li; Hu, Kaikai; Guan, Yan-Qing

    2016-03-30

    The destruction of PVC cables by termites is a continuing and long-standing problem, which can lead to power leakage and power cut. Given the environmental demerits of insecticide overuse, alternative methods of addressing this problem are a highly desirable goal. In this study, we used photo-immobilization to develop a chitosan carrier system to help bifenthrin immobilize on the surface of the PVC substrate. The immobilization was analyzed using nuclear magnetic resonance (NMR), UV absorption, reverse-phase high-performance liquid chromatography (RP-HPLC), Raman absorption spectroscopy, and thermal gravimetric analysis (TGA). The surface structure and biological activity of the embedded and immobilized bifenthrin were examined using scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray photon-electron spectroscopy (XPS). Its efficacy was assessed in pest experiments. The results indicate a successful embedding and immobilization of bifenthrin. Furthermore, the chemical bonding network between AzPhchitosan, bifenthrin, and PVC is stable, guaranteeing no environmental release of bifenthrin, and also providing more efficacious protection against termites. The evidence suggests that this photo-immobilization of bifenthrin-embedded chitosan on the surface of PVC substrates is a novel and environmentally friendly technique for termite control. This paper also reports a modification of chitosan with respect to its novel application in environmental protection. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Analysis of Phthalate Ester Content in PVC Plastics by means of FT-Raman Spectroscopy

    DEFF Research Database (Denmark)

    Nørbygaard, Thomas; Berg, Rolf W.

    2004-01-01

    Polyvinyl chloride, PVC or [CH2-CHCl]n , is a common polymer used extensively for a wide range of industrial and household products. To achieve the proper material characteristics (e.g. softness, ductility), plasticizers such as phthalates are usually added to the otherwise hard and brittle PVC......, medical devices and toys may harm the e.g. reproductive organs of exposed infants. PVC is readily distinguished from other common polymers (e.g. polyethylene, polypropylene, polystyrene) by the use of Raman spectroscopy. By far the most commonly used phthalate plasticizer in PVC is di(2-ethylhexyl......-phenyl group, and as the relative intensities of the six bands vary only slightly from one phthalate ester to the next one we have obtained an identifiable, characteristic fingerprint of the phthalate ester group as a whole. By use of the set of six bands, which are common to all the measured Raman spectra, we...

  19. Designed biocompatible nano-inhibitor based on poly(β-cyclodextrin-ester) for reduction of the DEHP migration from plasticized PVC.

    Science.gov (United States)

    Raeisi, Ahmad; Faghihi, Khalil; Shabanian, Meisam

    2017-10-15

    The easy migration of di(2-ethylhexyl) phthalate (DEHP) from the plasticized PVC (P-PVC) poses a serious threat to human health and the ecosystems. Thus, its control migration from the P-PVC products is very important. In this work, a poly(β-cyclodextrin-ester) network (β-CDP) was synthesized via reaction of β-cyclodextrin with 3,3',4,4'-benzophenone tetracarboxylic dianhydride. As a potential inhibitor for reduction of the DEHP migration, the β-CDP was grafted to Fe 3 O 4 nanoparticles. Poly(β-cyclodextrin-ester) functionalized Fe 3 O 4 nanoparticles (MNP-CDP) has been used in PVC/DEHP system as a reactive nano-inhibitor to reduce DEHP migration. Thermal stability and mechanical properties of obtained films were investigated. DEHP migration tests of the P-PVC films were also carried out by using Gas chromatography. It was found that by incorporating the small amounts of nano-inhibitor in PVC/DEHP system, the migration of DEHP effectively reduced from the P-PVC samples about 65% without any serious changes in mechanical and thermal properties of the P-PVC films. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. High photocatalytic degradation activity of the polyvinyl chloride (PVC)-vitamin C (VC)-TiO{sub 2} nano-composite film

    Energy Technology Data Exchange (ETDEWEB)

    Yang Changjun; Gong Chuqing; Peng Tianyou [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); Deng Kejian [Key Laboratory of Catalysis and Materials Science of the State Ethnic Affairs Commission and Ministry of Education, South-Central University for Nationalities, Wuhan 430074 (China); Zan Ling, E-mail: irlab@whu.edu.cn [College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China)

    2010-06-15

    A novel photodegradable polyvinyl chloride (PVC)-vitamin C (VC)-TiO{sub 2} nano-composite film was prepared by embedding VC modified nano-TiO{sub 2} photocatalyst into the commercial PVC plastic. The solid-phase photocatalytic degradation behavior of PVC-VC-TiO{sub 2} nano-composite film under UV light irradiation was investigated and compared with those of the PVC-TiO{sub 2} film and the pure PVC film, with the aid of UV-Vis spectroscopy, scanning electron microscopy (SEM), weight loss monitoring, and X-ray diffraction spectra (XRD). The results show that PVC-VC-TiO{sub 2} nano-composite film has a high photocatalytic activity; the photocatalytic degradation rate of it is two times higher than that of PVC-TiO{sub 2} film and fifteen times higher than that of pure PVC film. The optimal mass ratio of VC to TiO{sub 2} is found to be 0.5. The mechanism of enhancing photocatalytic activity is attributed to the formation of a Ti{sup IV}-VC charge-transfer complex with five-member chelate ring structure and a rapid photogenerated charge separation is thus achieved.

  1. CLINICAL STUDY AND MANAGEMENT OF BENIGN GASTROINTESTINAL PERFORATIONS

    Directory of Open Access Journals (Sweden)

    Kishan

    2016-05-01

    Full Text Available INTRODUCTION Peritonitis due to gastrointestinal perforation is one of the commonest surgical emergencies encountered by a general surgeon. (1,2 Mortality and morbidity is still very high despite early diagnosis and intensive management. This study is aimed to find common causes of perforations, its presentations, mode of investigations and treatment done and outcome of patients. METHODS Case records of all patients, in exclusion and inclusion criteria, who were admitted in emergency surgical ward with suspected GI perforation and peritonitis were included in study and diagnosis confirmed by either investigations preoperatively or by laparotomy and results analysed over a period of 16 months. RESULTS GI perforations due to benign causes are most common causes of peritonitis, of which gastroduodenal perforations are commonest followed by appendicular perforation closely followed by infective perforations. CONCLUSION Benign causes of upper gastroduodenal perforations are common causes of peritonitis (2,3. Mortality increases with delay in presentation and treatment. Abdominal signs like guarding rigidity are present in majority of cases. X-ray erect abdomen was effective in detecting perforation in majority of cases. Surgery is the treatment in all cases of perforation.

  2. Using bamboo (Bambusa vulgaris) as a field drainage material in ...

    African Journals Online (AJOL)

    user

    shaped ceramic tile, circular clay tile, concrete tile, bituminized fibre perforated pipe, perforated smooth plastic pipe to corrugated plastic pipe. Currently, corrugated pipes are frequently used, although clay and concrete pipes are still being used as well. The use of drainage pipes made of various assorted materials is.

  3. Model fire tests on polyphosphazene rubber and polyvinyl chloride (PVC)/nitrile rubber foams

    Science.gov (United States)

    Widenor, W. M.

    1978-01-01

    A video tape record of model room fire tests was shown, comparing polyphosphazene (P-N) rubber and polyvinyl chloride (PVC)/nitrile rubber closed-cell foams as interior finish thermal insulation under conditions directly translatable to an actual fire situation. Flashover did not occur with the P-N foam and only moderate amounts of low density smoke were formed, whereas with the PVC/nitrile foam, flashover occurred quickly and large volumes of high density smoke were emitted. The P-N foam was produced in a pilot plant under carefully controlled conditions. The PVC/nitrile foam was a commercial product. A major phase of the overall program involved fire tests on P-N open-cell foam cushioning.

  4. Production of PVC/Abs/Nbr blend and the study of its physical and mechanical properties, thermal behaviour and its morphology

    International Nuclear Information System (INIS)

    Mehrabzadeh, M.; Honarkar, H.

    2001-01-01

    In this research a product of triplet blend of polyvinyl chloride, acrylonitrile-butadiene-styrene, acrylonitrile butadiene rubber (PVC/Abs/Nbr) is obtained. The physical, mechanical and thermal behaviour as well as morphology of the blend were studied. Results show that optimum properties in ratio PVC/Abs: 60/40 is obtained. For substituting the Nbr by a portion of Dop to modify the migration to surface, a triplet blend of PVC/Abs/Nbr was made. Experiments with constant amount of Nbr and variable Dop and vice versa were carried out. For preparation of triplet blend from PVC/Abs, a ratio of 60/40 was used. The best results were obtained for a blend with Nbr (10%) and PVC powder, 20% Nbr and PVC granules containing 34% Dop and the thermo formability of PVC/Abs/Nbr blend was examined as well

  5. Perforated peptic ulcer

    DEFF Research Database (Denmark)

    Søreide, Kjetil; Thorsen, Kenneth; Harrison, Ewen M

    2015-01-01

    Perforated peptic ulcer is a common emergency condition worldwide, with associated mortality rates of up to 30%. A scarcity of high-quality studies about the condition limits the knowledge base for clinical decision making, but a few published randomised trials are available. Although Helicobacter...... need further assessment. Adequate trials with low risk of bias are urgently needed to provide better evidence. We summarise the evidence for perforated peptic ulcer management and identify directions for future clinical research....

  6. Improving the Healthiness of Sustainable Construction: Example of Polyvinyl Chloride (PVC

    Directory of Open Access Journals (Sweden)

    Emina Kristina Petrović

    2018-02-01

    Full Text Available With the increasing emphasis on sustainable construction, it has become important to better understand the impacts of common materials. This is especially paramount with the introduction of the United Nations (UN Sustainable Development Goals (SDGs which call for more comprehensive evaluations, adding many aspects of social consideration to the issues of environmental sustainability, including human health. Polyvinyl chloride (PVC/vinyl can be seen as a material with potential for significant adverse effects on a multiplicity of levels, and the construction industry is its single most significant consumer. This article presents a transdisciplinary review of adverse health impacts associated with PVC showing a number of issues: some that could be eliminated through design, but also some which appear inherent to the material itself and therefore unavoidable. The totality of issues revealed in relation to PVC presents a compelling case for a call for complete elimination of use of this material in sustainable construction.

  7. Producción y modelamiento de gliceril-ésteres como plastificantes para PVC / Production et modelisation de glycerol-esters comme plastifiants pour le PVC

    OpenAIRE

    Suárez Palacios, Oscar Yesid

    2011-01-01

    El aumento en la producción mundial de glicerina, debido al crecimiento en el uso de biodiesel, y la tendencia a reemplazar los plastificantes derivados del anhídrido ftálico en la industria del PVC, por la toxicidad de dichas sustancias, motivaron la investigación de la plastificación del PVC con gliceril-ésteres derivados de ácidos carboxílicos de cadena corta (C3 - C8) y aromáticos. En este estudio se aplicó una metodología de diseño de producto para abordar la solución a las problemáticas...

  8. Optimization of geometrical characteristics of perforated plates

    International Nuclear Information System (INIS)

    Radisavljevic, Igor; Balos, Sebastian; Nikacevic, Milutin; Sidjanin, Leposava

    2013-01-01

    Highlights: ► Perforated plate are tested against 12.7 mm API projectile. ► Perforations similar to the projectile diameter offer more efficient core fracture. ► Larger perforations gave a more efficient core fragmentation. ► SEM microscopy analysis has shown a ductile fracture mode at impact point. - Abstract: In this paper, an attempt was made to design effective non-homogenous armor in form of perforated plate mounted at close distance from basic armor plate. Perforated plate with three perforation diameters: 9, 10 and 11 mm, two ligaments length: 3.5 and 4.5 mm ligaments, set at 0° and 28° angles, were combined to 13 mm basic plate and tested against 12.7 mm API ammunition. It has been shown that larger perforations gave a more efficient core fragmentation, while angled specimens were the only ones that offer full protection against five API shots when the perforated plate was placed at 100 mm from the basic plate. Perforations that are similar in size to the penetrating core diameter offer a more efficient core fracture, leading to a faster fragment separation. This may enable a smaller distance between the add-on perforated and basic plate to be used. Scanning electron microscopy analysis has shown a ductile fracture mode at impact point, with hardness values on plate basic level. On the other hand, a brittle fracture mode with a rise in local hardness measured near impact point is a result of intensive high speed plastic deformation produced by bending stresses. A drop in local hardness measured near impact point, may be the result of intensive cracking that occur due to repeated projectile impact

  9. Effects of 60 MeV C5+ ion irradiation on PmT-PVC and p-TSA doped PoT-PVC blends

    International Nuclear Information System (INIS)

    Lakshmi, G.B.V.S.; Siddiqui, Azher M.; Ali, Vazid; Kulriya, Pawan K.; Zulfequar, M.

    2008-01-01

    Poly(m-toluidine) (PmT) and Poly(o-toluidine) (PoT) have been synthesized from derivatives of aniline (m-toluidine), (o-toluidine) monomers by chemical oxidative polymerization method. After polymerization, PoT powder was doped with p-toluene sulphonic acid (p-TSA) and the polymer powders were blended with poly vinyl chloride (PVC) to achieve PmT and p-TSA doped PoT dispersed films. XRD, FTIR and UV-visible studies were carried out to get their structural changes and optical information. These blends were irradiated by 60 MeV C 5+ ions with different fluences. Post Irradiation XRD, FTIR and UV-visible spectroscopy were also performed on all films. On p-TSA doped PoT-PVC blends dc-conductivity measurements are also carried out before and after irradiation. The results show structural modifications which lead to changes in optical and electrical properties

  10. Multiple, Pan-Enteric Perforation Secondary to Intestinal Tuberculosis

    Science.gov (United States)

    Masood, Irfan; Majid, Zain; Rafiq, Ali; Rind, Waqas; Zia, Aisha; Raza, Sajjad

    2015-01-01

    Free perforation is one of the most feared complications of the intestinal tuberculosis. The terminal ileum is the most common site of perforation, while the majority of (90%) perforations are solitary. Herein, we describe a case of a 25-year-old male who presented with generalized peritonitis requiring an emergency exploratory laparotomy, which revealed pan-enteric perforation characterized by multiple perforations of the small bowel extending 10–15 cm from the DJ flexure up to the terminal ileum. The perforations were primarily closed, while 6–8 cm of the diseased terminal ileum was resected and the two ends were brought out as double-barreled ostomy. To the best of our knowledge, such an extensive tuberculous perforation of the small bowel has not been previously reported in the literature before. PMID:26798540

  11. Mechanical behavior of styrene grafted PVC films by electron beam irradiation

    International Nuclear Information System (INIS)

    Cardoso, Jessica R.; Moura, Eduardo; Somessari, Elisabeth S.R.; Silveira, Carlos G.; Paes, Helio A.; Souza, Carlos A.; Manzoli, Jose E.; Geraldo, Aurea B.C.

    2011-01-01

    The polyvinyl chloride (PVC) is a technological and low cost polymer, however it presents high sensitivity to high energy irradiation because of the weakness of carbon-chloride bond face to carbon-carbon and carbon-hydrogen bonds. Grafting is a type of co-polymerization process that can allow it an increase of mechanical characteristics. The aim of this work is to evaluate the mechanical properties of styrene grafted PVC by electron beam irradiation using mutual and pre-irradiation methods to verify the mechanical resistance changes of obtained product whether grafting process is applied from non-irradiated or from pre-irradiated substrates. The irradiation procedures were performed in atmosphere air or inert atmosphere and the irradiation conditions comprised doses from 10 kGy to 100 kGy and dose rates of 2.2 kGy/s and 22.4 kGy/s. The styrene grafted samples were analyzed by gravimetry to determinate the grafting yield; the final values have been averaged from a series of three measurements. The Mid-A TR-FTIR was the spectrophotometer technique used for qualitative/semi-quantitative analysis of grafted samples. The Young's module and tensile strength of pre-irradiated and grafted PVC samples at both methods were measured at a Lloyd LXR tensile tester at a cross-head speed of 10.00 mm/min. We observed the decrease of Young's module and tensile strength with the increase of absorbed dose at pre-irradiated PVC samples. These mechanical parameters results are discussed. (author)

  12. Effect of Thermal Shock During Legionella Bacteria Removal on the Corrosion Properties of Zinc-Coated Steel Pipes

    Science.gov (United States)

    Orlikowski, Juliusz; Ryl, Jacek; Jazdzewska, Agata; Krakowiak, Stefan

    2016-07-01

    The purpose of this investigation was to conduct the failure analysis of a water-supply system made from zinc-coated steel. The observed corrosion process had an intense and complex character. The brownish deposits and perforations were present after 2-3 years of exploitation. The electrochemical study based on the Tafel polarization, corrosion potential monitoring, and electrochemical impedance spectroscopy together with microscopic analysis via SEM and EDX were performed in order to identify the cause of such intense corrosion. The performed measurements allowed us to determine that thermal shock was the source of polarity-reversal phenomenon. This process had begun the corrosion of steel which later led to the formation of deposits and perforations in the pipes. The work includes appropriate action in order to efficiently identify the described corrosion threat.

  13. Mortality risk factor analysis in colonic perforation: would retroperitoneal contamination increase mortality in colonic perforation?

    Science.gov (United States)

    Yoo, Ri Na; Kye, Bong-Hyeon; Kim, Gun; Kim, Hyung Jin; Cho, Hyeon-Min

    2017-10-01

    Colonic perforation is a lethal condition presenting high morbidity and mortality in spite of urgent surgical treatment. This study investigated the surgical outcome of patients with colonic perforation associated with retroperitoneal contamination. Retrospective analysis was performed for 30 patients diagnosed with colonic perforation caused by either inflammation or ischemia who underwent urgent surgical treatment in our facility from January 2005 to December 2014. Patient characteristics were analyzed to find risk factors correlated with increased postoperative mortality. Using the Physiological and Operative Severity Score for the Enumeration of Mortality and Morbidity (POSSUM) audit system, the mortality and morbidity rates were estimated to verify the surgical outcomes. Patients with retroperitoneal contamination, defined by the presence of retroperitoneal air in the preoperative abdominopelvic CT, were compared to those without retroperitoneal contamination. Eight out of 30 patients (26.7%) with colonic perforation had died after urgent surgical treatment. Factors associated with mortality included age, American Society of Anesthesiologists (ASA) physical status classification, and the ischemic cause of colonic perforation. Three out of 6 patients (50%) who presented retroperitoneal contamination were deceased. Although the patients with retroperitoneal contamination did not show significant increase in the mortality rate, they showed significantly higher ASA physical status classification than those without retroperitoneal contamination. The mortality rate predicted from Portsmouth POSSUM was higher in the patients with retroperitoneal contamination. Patients presenting colonic perforation along with retroperitoneal contamination demonstrated severe comorbidity. However, retroperitoneal contamination was not found to be correlated with the mortality rate.

  14. Electron beam processing of PVC insulating material in presence of additives

    International Nuclear Information System (INIS)

    Sharma, V.K.; Bhattacharyya, P.K.

    1994-01-01

    Using electron beam radiation flexible PVC (polyvinyl chloride) was cross linked in the dose range up to 15 Mrad. The effect of sensitizers and other additives on the cross linking and other physical properties like tensile strength have been investigated. It has been found that tri functional sensitizer like TMPTM (tri methyl propane tri methacrylate) is better sensitizer for PVC. In presence of TMPTM the physical properties related to crosslinking are found to be better than some of the other sensitizers used. The results are discussed. (author). 2 refs., 2 figs

  15. Multiple, Pan-Enteric Perforation Secondary to Intestinal Tuberculosis

    Directory of Open Access Journals (Sweden)

    Irfan Masood

    2015-01-01

    Full Text Available Free perforation is one of the most feared complications of the intestinal tuberculosis. The terminal ileum is the most common site of perforation, while the majority of (90% perforations are solitary. Herein, we describe a case of a 25-year-old male who presented with generalized peritonitis requiring an emergency exploratory laparotomy, which revealed pan-enteric perforation characterized by multiple perforations of the small bowel extending 10–15 cm from the DJ flexure up to the terminal ileum. The perforations were primarily closed, while 6–8 cm of the diseased terminal ileum was resected and the two ends were brought out as double-barreled ostomy. To the best of our knowledge, such an extensive tuberculous perforation of the small bowel has not been previously reported in the literature before.

  16. STUDY OF CLINICAL OUTCOMES OF SUBFASCIAL PERFORATOR LIGATION SURGERY IN PERFORATOR INCOMPETENCE

    Directory of Open Access Journals (Sweden)

    Vasuki Rajam

    2017-02-01

    Full Text Available BACKGROUND Chronic venous insufficiency presents with a spectrum of clinical features ranging from pain or heaviness of affected limbs to non-healing ulcers over the lower limbs and usually require some form of surgical intervention, performing direct perforator vein division preferably by subfascial endoscopic perforator ligation surgery for perforator incompetence, as despite aggressive conservative therapy including compression, lifestyle modification and venotonic medications which are of high cost treatment with increased risk of increasing symptoms. MATERIALS AND METHODS A prospective longitudinal clinical study of 30 patients selected by systematic sampling method from November 2014 to September 2015 at our institution was conducted to determine the results of subfascial endoscopic perforator vein surgery (SEPS in perforator incompetence. RESULTS For venous clinical severity scoring pre operatively and after 3 weeks post-surgery, the mean for VCSS pre-operatively was 6.66 and a standard deviation of 2.399. The T value was calculated and was found to be 4.9321 and p value of 0.00001(p value less than 0.05 is significant. Similarly for the cases with active ulcer, the size assessment pre-operatively and post-SEPS was again analysed using student t test and the mean ulcer size prior to surgery was found to be 3.3 and standard deviation of 1.984. The T value was calculated and was found to be 1.789009 and a p value of 0.04 (p value less than 0.05 is significant. CONCLUSION Our study concluded that favourable and significant ulcer healing rate with improvement and reduction in clinical severity suggests that SEPS plays an important role in surgical management of advanced stages of venous insufficiency.

  17. Study on the gamma radiolysis of poly (vinyl chloride). Application to the study on degradation by irradiation and leaching of industrial PVC

    International Nuclear Information System (INIS)

    Colombani, J.

    2006-01-01

    The works presented in this memory enter in the context of the management of plastic nuclear waste. This study was carried out on pure PVC and industrial PVC (formulated polymer). The radiolysis at high doses (up to 4 MGy) of pure PVC in anaerobic condition involves the formation of polyenyl radicals, polyenic sequences, hydrogen chloride and reactions of crosslinking. In aerobic condition, the radiolysis at high doses of pure PVC generates the formation of peroxyl radicals, hydrogen chloride, acid water, carboxylic acids, saturated or conjugated ketones and phenomena of scission. The production of HCl generated by irradiation of industrial PVC was carried out up to 40 MGy. The HCl formed by radiolysis is completely trapped by the calcic loads contained in industrial PVC and by the water produced by these reactions of trapping. A qualitative study on the formation of the products of radiolysis highlighted that the mechanisms of radiolysis of industrial PVC are different from those of pure PVC. This difference is due to the presence of additives belonging to the formulation of industrial PVC. The irradiation of plasticizers such as phthalic esters could induce the formation of radicals being able to react, by reaction of grafting, with the macro-radicals of PVC or with the polyenic sequences formed by radiolysis of PVC macromolecules. The results of leaching experiments tend to confirm this type of mechanism. (author)

  18. Thermal stability of formulations of PVC irradiated with {gamma} of {sup 60}; Estabilidad termica de formulaciones de PVC irradiadas con {gamma} de {sup 60} Co

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M.E.; Carrasco A, H. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)]. E-mail: memp@nuclear.inin.mx; Castaneda F, A.; Benavides C, R.; Garcia R, S.P. [CIQA, 25100 Saltillo, Coahuila (Mexico)

    2004-07-01

    The industry of cables and wires frequently use cable isolations with base of formulations of PVC, in those that stabilizer has usually been used with the help of heavy metals, as the lead, which is toxic. To solve the problem, from the 2002 one has come studying in combined form in the National Institute of Nuclear Research ININ and the Center of Investigation in Applied Chemistry CIQA, the modifications induced by the radiation in formulations with the help of vinyl poly chloride PVC. In these formulations, prepared with cross linking agent, plastifying industrial grade, stuff and non toxic stabilizers of calcium estearate and zinc industrial grade, it is sought to replace the stabilizer of Pb. For this were irradiated it test tubes of PVC with gamma radiation of cobalt 60 to three different dose in atmospheres of air and argon. Later it was determined their thermal stability at different times of heating and it was measured the Young modulus by means of thermo mechanical analysis. Those results obtained together with other techniques of characterization suggest that the irradiated proposed formulation can substitute the one stabilized with lead. (Author)

  19. Tricholithobezoar Causing Gastric Perforation

    Directory of Open Access Journals (Sweden)

    Juliana Santos Valenciano

    2012-01-01

    Full Text Available A bezoar is an intraluminal mass formed by the accumulation of undigested material in the gastrointestinal tract. Trichobezoar is a rare condition seen almost exclusively in young women with trichotillomania and trichotillophagia. When not recognized, the trichobezoar continues to grow, which increases the risk of severe complications such as gastric ulceration and even perforation. Formation of a gallstone within the trichobezoar (tricholithobezoar is an event that has not yet been described. We report the case of a 22-year-old woman admitted to the emergency room with signals and symptoms of an epigastric mass and perforative acute abdomen. Radiological study revealed bilateral pneumoperitoneum. Personal history revealed depressive syndrome, trichotillomania and trichophagia. With a diagnosis of visceral perforation, an urgent exploratory laparotomy was performed. This confirmed the diagnosis of gastric perforation due to a large trichobezoar with the formation of a gastrolith that was removed by anterior gastrotomy. Biochemical study of the gastric stone revealed that it was composed of bile salts. There were no complications. The patient was discharged on the 5th postoperative day and was referred for psychiatric treatment.

  20. Clinical applications of the superior epigastric artery perforator (SEAP) flap: anatomical studies and preoperative perforator mapping with multidetector CT.

    Science.gov (United States)

    Hamdi, Moustapha; Van Landuyt, Koenraad; Ulens, Sara; Van Hedent, Eddy; Roche, Nathalie; Monstrey, Stan

    2009-09-01

    Pedicled superior epigastric artery perforator (SEAP) flaps can be raised to cover challenging thoracic defects. We present an anatomical study based on multidetector computerized tomography (MDCT) scan findings of the SEA perforators in addition to the first reported clinical series of SEAP flaps in anterior chest wall reconstruction. (a) In the CT scan study, images of a group of 20 patients who underwent MDCT scan analysis were used to visualise bilaterally the location of musculocutaneous SEAP. X- and Y-axes were used as landmarks to localise the perforators. The X-axis is a horizontal line at the junction of sternum and xyphoid (JCX) and the Y-axis is at the midline. (b) In the clinical study, seven pedicled SEAP flaps were performed in another group of patients. MDCT images revealed totally 157 perforators with a mean of 7.85 perforators per patient. The dominant perforators (137 perforators) were mainly localised in an area between 1.5 and 6.5 cm from the X-axis on both sides and between 3 and 16 cm below the Y-axis. The calibre of these dominant perforators was judged as 'good' to 'very good' in 82.5% of the cases. The average dimension of the flap was 21.7x6.7 cm. All flaps were based on one perforator. Mean harvesting time was 110 min. There were no flap losses. Minor tip necrosis occurred in two flaps. One of them was treated with excision and primary closure. Our clinical experience indicates that the SEAP flap provides a novel and useful approach for reconstruction of anterior chest wall defects. CT-based imaging allows for anatomical assessment of the perforators of the superior epigastric artery (SEA).

  1. Research on the Perforating Algorithm Based on STL Files

    Science.gov (United States)

    Yuchuan, Han; Xianfeng, Zhu; Yunrui, Bai; Zhiwen, Wu

    2018-04-01

    In the process of making medical personalized external fixation brace, the 3D data file should be perforated to increase the air permeability and reduce the weight. In this paper, a perforating algorithm for 3D STL file is proposed, which can perforate holes, hollow characters and engrave decorative patterns on STL files. The perforating process is composed of three steps. Firstly, make the imaginary space surface intersect with the STL model, and reconstruct triangles at the intersection. Secondly, delete the triangular facets inside the space surface and make a hole on the STL model. Thirdly, triangulate the inner surface of the hole, and thus realize the perforating. Choose the simple space equations such as cylindrical and rectangular prism equations as perforating equations can perforate round holes and rectangular holes. Through the combination of different holes, lettering, perforating decorative patterns and other perforated results can be accomplished. At last, an external fixation brace and an individual pen container were perforated holes using the algorithm, and the expected results were reached, which proved the algorithm is feasible.

  2. Spectrum of perforation peritonitis in Pakistan: 300 cases Eastern experience.

    Science.gov (United States)

    Afridi, Shahida Parveen; Malik, Faiza; Ur-Rahman, Shafiq; Shamim, Shahid; Samo, Khursheed A

    2008-11-08

    Perforation peritonitis is the most common surgical emergency encountered by the surgeons all over the world as well in Pakistan. The spectrum of etiology of perforation peritonitis in tropical countries continues to differ from its western counter part. This study was conducted at Dow University of health sciences and Civil Hospital Karachi (DUHS & CHK) Pakistan, designed to highlight the spectrum of perforation peritonitis in the East and to improve its outcome. A prospective study includes three hundred consecutive patients of perforation peritonitis studied in terms of clinical presentations, Causes, site of perforation, surgical treatment, post operative complications and mortality, at (DUHS&CHK) Pakistan, from 1st September 2005 - 1st March 2008, over a period of two and half years. All patients were resuscitated underwent emergency exploratory laparotomy. On laparotomy cause of perforation peritonitis was found and controlled. The most common cause of perforation peritonitis noticed in our series was acid peptic disease 45%, perforated duodenal ulcer (43.6%) and gastric ulcer 1.3%. followed by small bowel tuberculosis (21%) and typhoid (17%). large bowel perforation due to tuberculosis 5%, malignancy 2.6% and volvulus 0.3%. Perforation due to acute appendicitis (5%). Highest number of perforations has seen in the duodenum 43.6%, ileum37.6%, and colon 8%, appendix 5%, jejunum 3.3%, and stomach 2.3%. Overall mortality was (10.6%). The spectrum of perforation peritonitis in Pakistan continuously differs from western country. Highest number of perforations noticed in the upper part of the gastrointestinal tract as compared to the western countries where the perforations seen mostly in the distal part. Most common cause of perforation peritonitis is perforated duodenal ulcer, followed by small bowel tuberculosis and typhoid perforation. Majority of the large bowel perforations are also tubercular. Malignant perforations are least common in our setup.

  3. Spectrum of perforation peritonitis in Pakistan: 300 cases Eastern experience

    Directory of Open Access Journals (Sweden)

    Ur-Rahman Shafiq

    2008-11-01

    Full Text Available Abstract Background Perforation peritonitis is the most common surgical emergency encountered by the surgeons all over the world as well in Pakistan. The spectrum of etiology of perforation peritonitis in tropical countries continues to differ from its western counter part. This study was conducted at Dow University of health sciences and Civil Hospital Karachi (DUHS & CHK Pakistan, designed to highlight the spectrum of perforation peritonitis in the East and to improve its outcome. Methods A prospective study includes three hundred consecutive patients of perforation peritonitis studied in terms of clinical presentations, Causes, site of perforation, surgical treatment, post operative complications and mortality, at (DUHS&CHK Pakistan, from 1st September 2005 – 1st March 2008, over a period of two and half years. All patients were resuscitated underwent emergency exploratory laparotomy. On laparotomy cause of perforation peritonitis was found and controlled. Results The most common cause of perforation peritonitis noticed in our series was acid peptic disease 45%, perforated duodenal ulcer (43.6% and gastric ulcer 1.3%. followed by small bowel tuberculosis (21% and typhoid (17%. large bowel perforation due to tuberculosis 5%, malignancy 2.6% and volvulus 0.3%. Perforation due to acute appendicitis (5%. Highest number of perforations has seen in the duodenum 43.6%, ileum37.6%, and colon 8%, appendix 5%, jejunum 3.3%, and stomach 2.3%. Overall mortality was (10.6%. Conclusion The spectrum of perforation peritonitis in Pakistan continuously differs from western country. Highest number of perforations noticed in the upper part of the gastrointestinal tract as compared to the western countries where the perforations seen mostly in the distal part. Most common cause of perforation peritonitis is perforated duodenal ulcer, followed by small bowel tuberculosis and typhoid perforation. Majority of the large bowel perforations are also tubercular

  4. Effects of low dose gamma irradiation on PVC blood bags containing anticoagulant CPDA solution

    International Nuclear Information System (INIS)

    Mitra, D.; Varshney, Lalit; Arjun, Chanda

    2006-01-01

    PVC blood bags were exposed to 20Gy and 60Gy low gamma radiation dose to investigate possibility of change in leaching behavior of the plasticizer into CPDA solution and the blood. Reversed phase HPLC was used for the investigations on anti coagulant solution CPDA(citrate, phosphate, dextrose and adenine) contained in PVC bag before and after gamma irradiation. The studies were repeated using methanol as an extractant instead of CPDA solution, considering higher extractability of plasticizer by blood. Irradiation of PVC bags by gamma radiation for a dose up to 60Gy does not lead to change in leaching behavior of the plasticizer in CPDA solution and methanol indicating similar expected behavior in blood. (author)

  5. Colonic perforation following endoscopic retrograde ...

    African Journals Online (AJOL)

    She developed severe upper abdominal pain after the ... non-surgical management of pancreatitis and associated complications, colonic perforation should be considered in patients who deteriorate ... To our knowledge this is the first case of a secure pre-operative diagnosis of colonic perforation due to to pancreatitis.

  6. Experimental Investigations on Combustion Behaviors of Live PVC Cables

    Science.gov (United States)

    Wang, Liufang; Zhang, Jiaqing; Zhang, Bosi; Liu, Min; Fan, Minghao; Li, Qiang

    2018-03-01

    This paper investigated the combustion behaviors of live PVC cables with overload currents experimentally. The smoke coefficient of released smoke and the released gas concentration were examined. The results indicate that the combustion of live PVC cables can be divided into four stages, i.e., core exposed with a little smoke, obvious flame, maximum smoke and smoke depress. For most cases, using blue laser is better than using rad laser, since the extinction coefficient of the rad laser was larger than that of the blue laser. The response time of the detection of the released typical gases due to cable pyrolysis decreased and the peak values of the typical gases increased with the overload currents. In addition, the time to reach the peak value of gas concentration also decreased with the overload currents.

  7. Mechanical behavior of styrene grafted PVC films by electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Jessica R.; Moura, Eduardo; Somessari, Elisabeth S.R.; Silveira, Carlos G.; Paes, Helio A.; Souza, Carlos A.; Manzoli, Jose E.; Geraldo, Aurea B.C., E-mail: ageraldo@ipen.br, E-mail: jmanzoli@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The polyvinyl chloride (PVC) is a technological and low cost polymer, however it presents high sensitivity to high energy irradiation because of the weakness of carbon-chloride bond face to carbon-carbon and carbon-hydrogen bonds. Grafting is a type of co-polymerization process that can allow it an increase of mechanical characteristics. The aim of this work is to evaluate the mechanical properties of styrene grafted PVC by electron beam irradiation using mutual and pre-irradiation methods to verify the mechanical resistance changes of obtained product whether grafting process is applied from non-irradiated or from pre-irradiated substrates. The irradiation procedures were performed in atmosphere air or inert atmosphere and the irradiation conditions comprised doses from 10 kGy to 100 kGy and dose rates of 2.2 kGy/s and 22.4 kGy/s. The styrene grafted samples were analyzed by gravimetry to determinate the grafting yield; the final values have been averaged from a series of three measurements. The Mid-A TR-FTIR was the spectrophotometer technique used for qualitative/semi-quantitative analysis of grafted samples. The Young's module and tensile strength of pre-irradiated and grafted PVC samples at both methods were measured at a Lloyd LXR tensile tester at a cross-head speed of 10.00 mm/min. We observed the decrease of Young's module and tensile strength with the increase of absorbed dose at pre-irradiated PVC samples. These mechanical parameters results are discussed. (author)

  8. Radiologic Study of Meniscus Perforations in the Temporomandibular Joint

    International Nuclear Information System (INIS)

    Kim, Kee Duck; Park, Chang Seo

    1990-01-01

    Thirty-nine patients (forty-four joints) who had been diagnosed as having meniscus perforation of the temporomandibular joint by inferior joint space arthrography and had been treated by surgical procedures were evaluated retrospectively. Information of clinical findings, arthrotomographic findings and surgical findings was collected on a standardized form and evaluated. The results were as follows: 1. On the 34 patients of 38 joints which were surgically confirmed perforation of meniscus or its attachments of the temporomandibular joint, there were 29 females and 5 males (5.8:1). The average age was 36 years (range 17 to 70). 2. The common clinical findings of group that had meniscus displacement without reduction and with perforation were pain on the affected joint and limitation of mouth opening. In the group showing meniscus displacement with reduction and with perforation the common clinical findings were pain and clicking on the affected joint. 3. 32 joints (84.2%) were arthrotomographically anterior meniscus displacement without reduction and with perforation, 6 joints (15.8%) showed anterior meniscus displacement with reduction and with perforation. 4. Joints categorized arthrotomographically as having meniscus displacement without reduction and with perforation were less likely to have full translation of the condyle in comparison with the normal or meniscus displacement with reduction and with perforation groups (p<0.05) 5. The arthrographic findings of 44 joints having meniscus perforation were compared with surgical findings, there were 6 false positive findings of meniscus perforation, the reliability of arthrographic findings of meniscus perforation was a 86.4% correlation with surgical findings. 6. On the site of perforations of 38 joints which were surgically confirmed perforation of meniscus or its attachments, twenty-three of perforations (60.5%) were in location at the junction of the meniscus and posterior attachment, fourteen (36.9%) were

  9. Isolated jejunal perforation following blunt abdominal trauma

    Directory of Open Access Journals (Sweden)

    Ahmet Pergel

    2012-09-01

    Full Text Available Isolated perforation of the jejunum, following blunt abdominaltrauma, is extremely rare. These injuries aredifficult to diagnose because initial clinical signs are frequentlynonspecific and a delay in treatment increasesmortality and morbidity of the patients. Conventional radiogramsare often inadequate for diagnosing this subsetof trauma. For an accurate and timely diagnosis, thepossibility of bowel perforation and the need for repeatedexaminations should be kept in mind. Herein, we presenta 28-year-old man with isolated jejunal perforation followingblunt abdominal trauma.Key words: Blunt abdominal trauma, isolated jejunal perforation,early diagnosis

  10. Perforated peptic ulcer.

    Science.gov (United States)

    Søreide, Kjetil; Thorsen, Kenneth; Harrison, Ewen M; Bingener, Juliane; Møller, Morten H; Ohene-Yeboah, Michael; Søreide, Jon Arne

    2015-09-26

    Perforated peptic ulcer is a common emergency condition worldwide, with associated mortality rates of up to 30%. A scarcity of high-quality studies about the condition limits the knowledge base for clinical decision making, but a few published randomised trials are available. Although Helicobacter pylori and use of non-steroidal anti-inflammatory drugs are common causes, demographic differences in age, sex, perforation location, and underlying causes exist between countries, and mortality rates also vary. Clinical prediction rules are used, but accuracy varies with study population. Early surgery, either by laparoscopic or open repair, and proper sepsis management are essential for good outcome. Selected patients can be managed non-operatively or with novel endoscopic approaches, but validation of such methods in trials is needed. Quality of care, sepsis care bundles, and postoperative monitoring need further assessment. Adequate trials with low risk of bias are urgently needed to provide better evidence. We summarise the evidence for perforated peptic ulcer management and identify directions for future clinical research. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. [Saphenous perforator flap].

    Science.gov (United States)

    Winkel, R; Tajsic, N; Husum, H; Schlageter, M; Hanebuth, G; Hoffmann, R

    2013-04-01

    Replacement of full thickness soft tissue defects in the lower leg and ankle, appropriate to the defect and following the course of blood vessels feeding the skin of a distally hinged fasciocutaneous flap most reliably based on the individual anatomy of distal perforators of the posterior tibial artery. Full thickness soft tissue defects, up to 12 cm in length and up to 8 cm in width. Sufficient vascularization of the foot required, in osteomyelitis, and when joints, fractures, implants and tendons are exposed and when a split skin graft, a local flap, a suralis perforator flap or a free flap is not indicated. For patients, in whom a 1-2 h operation is not possible; necessity of angioplasty; decollement or scars around the distal perforators of the posterior tibial artery; local infection or necrosis of soft tissues and/or bone, which cannot be totally excised. Radical debridement; flap dissection without tourniquet; microdissection; design of the flap on the skin: pivot point ~ 10 cm (6-14 cm) proximal of the tip of the medial malleolus; base ~ 5 cm in width, between the course of the saphenous nerve and of the great saphenous vein and the Achilles tendon; adipofascial pedicle up to 15 cm in length sited over the septum between soleus and flexor digitorum muscles, following the course of the saphenous nerve, with a central skin stripe, which expands into a proximal skin island; skin island is outlined similar to the defect, but larger by 1 to 2 cm, surrounded by an adipofascial border: adjustment of the planning as well as of the elevation of these flaps according to the individual position and the caliber of perforators requires in each case the search for a perforator at the estimated pivot point. Delay of transposition, if the division of more than one perforator proximal to the pivot point obviously diminishes circulation. No "tunnelling "of the pedicle; defects of skin due to the elevation of the flap are replaced by split and meshed skin grafts or temporary

  12. Perforated marginal ulcers after laparoscopic gastric bypass.

    Science.gov (United States)

    Felix, Edward L; Kettelle, John; Mobley, Elijah; Swartz, Daniel

    2008-10-01

    Perforated marginal ulcer (PMU) after laparoscopic Roux-en-Y gastric bypass (LRYGB) is a serious complication, but its incidence and etiology have rarely been investigated. Therefore, a retrospective review of all patients undergoing LRYGB at the authors' center was conducted to determine the incidence of PMU and whether any causative factors were present. A prospectively kept database of all patients at the authors' bariatric center was retrospectively reviewed. The complete records of patients with a PMU were examined individually for accuracy and analyzed for treatment, outcome, and possible underlying causes of the marginal perforation. Between April 1999 and August 2007, 1% of the patients (35/3,430) undergoing laparoscopic gastric bypass experienced one or more perforated marginal ulcers 3 to 70 months (median, 18 months) after LRYGB. The patients with and without perforation were not significantly different in terms of mean age (37 vs 41 years), weight (286 vs 287 lb), body mass index (BMI) (46 vs 47), or female gender (89% vs 83%). Of the patients with perforations, 2 (6%) were taking steroids, 10 (29%) were receiving nonsteroidal antiinflammatory drugs (NSAIDs) at the time of the perforation, 18 (51%) were actively smoking, and 6 of the smokers also were taking NSAIDs. Eleven of the patients (31%) who perforated did not have at least one of these possible risk factors, but 4 (36%) of the 11 patients in this group had been treated after bypass for a marginal ulcer. Only 7 (20%) of the 35 patients who had laparoscopic bypass, or 7 (0.2%) in the entire group of 3,430 patients, perforated without any warning. There were no deaths, but three patients reperforated. The incidence of a marginal ulcer perforating after LRYGB was significant (>1%) and appeared to be related to smoking or the use of NSAIDs or steroids. Because only 0.2% of all patients acutely perforated without some risk factor or warning, long-term ulcer prophylaxis or treatment may be necessary

  13. Imaging gastrointestinal perforation in pediatric blunt abdominal trauma

    International Nuclear Information System (INIS)

    Jamieson, D.H.; Babyn, P.S.; Pearl, R.

    1996-01-01

    Objective. To assess the role of imaging, in particular CT, in the early detection of GI perforation. Subjects and methods. In a 10-year period, 43 patients with surgically confirmed GI perforation were identified from hospital records; 22 of these had preoperative CT evaluation. Medical records and radiology were retrospectively reviewed and CT studies were particularly assessed for extraluminal air, free intraperitoneal fluid, bowel wall thickening, bowel wall enhancement, and bowel dilatation. During the study period an additional 12 trauma patients were identified who had CT studies demonstrating the above findings, but who had hypovolemic shock bowel or nondisrupting bowel injury without perforation evident. Results. Extraluminal air was demonstrated in 47 % of the imaged perforations. There was one false-positive extraluminal air. Perforation was confirmed in patients who had all five of the above CT findings, but this was the case for only 18 % of patients with perforation. One or more of the five specified CT findings were present in all CT studies reviewed. No false-negative CT study was performed in the study period. Conclusion. Separating nondisrupting bowel injury from perforation is diagnostically difficult; however, CT remains a good modality for assessing GI perforation in pediatric blunt trauma, but it cannot replace diligent and repeated clinical evaluation of all potential perforation victims. (orig.). With 4 figs., 1 tab

  14. Development and characterization of a synthetic PVC/DEHP myocardial tissue analogue material for CT imaging applications.

    Science.gov (United States)

    Ramadan, Sherif; Paul, Narinder; Naguib, Hani E

    2018-04-01

    A simple myocardial analogue material has great potential to help researchers in the creation of medical CT Imaging phantoms. This work aims to outline a Bis(2-ethylhexyl) phthalate (DEHP) plasticizer/PVC material to achieve this. DEHP-PVC was manufactured in three ratios, 75, 80, and 85% DEHP by heating at 110 °C for 10 min to promote DEHP-PVC binding followed by heating at 150 °C to melt the blend. The material was then tested utilizing FTIR, tensile testing, dynamic mechanical analysis and imaged with computed tomography. The FTIR testing finds the presence of C-CL and carbonyl bonds that demonstrate the binding required in this plasticized material. The tensile testing finds a modulus of 180-20 kPa that increases with the proportion of plasticizer. The dynamic mechanical analysis finds a linear increase in viscoelastic properties with a storage/loss modulus of 6/.5-120/18 kPa. Finally, the CT number of the material increases with higher PVC content from 55 to 144HU. The 80% DEHP-PVC ratio meets the mechanical and CT properties necessary to function as a myocardial tissue analogue.

  15. Analysis of Adipate Ester Contents in PVC Plastics

    DEFF Research Database (Denmark)

    Berg, Rolf W.

    2006-01-01

    Plasticizers are needed in flexible PVC (PolyVinylChloride) products. There is serious concern that commonly used phthalate esters may harm life reproduction systems. To avoid the problems, instead adipate di-esters (AEs) of C8 to C10 alcohols are used as higher prized alternatives; e.g. di-2......-ethylhexyl adipate or DEHA [103-23-1], also known as Adimoll® or di-octyl adipate, DOA, see Fig. 1. A widely used plasticizer in food (cling) films is DEHA, often in combination with polymers, epoxidized soya-bean oil, etcetera. DEHA also occurs in children toys. We have previously shown that the presence...... of phthalate esters in PVC can be rapidly analyzed by Fourier transform (FT-) Raman spectroscopy excited with a 1064 nm laser. Here in this project we report a similar study. The aim was to find out whether FT-Raman spectroscopy can be used to determine the presence of adipate esters (AEs) as plasticizers...

  16. Thermogravimetric-Mass Spectrometric Study of the Pyrolysis Behavior of PVC

    Institute of Scientific and Technical Information of China (English)

    SUN Qing-lei; SHI Xin-gang; LIN Yun-liang; ZHU He; WANG Xiao; CHENG Chuan-ge; LIU Jian-hua

    2007-01-01

    The pyrolysis characteristics of PVC were systematically investigated using a Netzschne TG thermo-balance coupled to a quadrupole mass spectrometer. The pyrolysis conditions were 0.1 MPa of Ar, a heating rate of 10 ℃/min and a final temperature of 1000 ℃. Both the thermogravimetric properties and the simultaneous evolution of gaseous products during pyrolysis were studied. The TG/DTG results showed that as the pyrolysis temperature increases the weight loss and weight loss rate of PVC increases. Near 412 ℃ the weight loss rate attained its peak value. At higher temperatures the rate of loss gradually decreases. The gases evolved during thermogravimetric analysis were analyzed by a mass spectrometer, monitoring the relative intensity of HCl, C6H6, light hydrocarbon and chlorine-containing gases. The evolution curves showed that HCl, C6H6, light hydrocarbon and chlorine-containing gases all peak at about 416 ℃. This is consistent with the fact that the weight loss curves also peak at about 412 ℃. The extensive HCl evolution is consistent with the high chlorine content of PVC. The formation of these gases can be explained by considering these reactions: dehydrochlorination, intramolecular cyclization and the addition of HCl to unsaturated hydrocarbons.

  17. PVC flooring at home and development of asthma among young children in Sweden, a 10-year follow-up.

    Science.gov (United States)

    Shu, H; Jönsson, B A; Larsson, M; Nånberg, E; Bornehag, C-G

    2014-06-01

    The incidence of asthma and allergy has increased throughout the developed world over the past decades. During the same period of time, the use of industrial chemicals such as phthalates, commonly used as plasticizers in polyvinylchloride (PVC) flooring material, has increased. The aim of this study was to investigate whether PVC flooring in the home of children in the age of 1-5 years is associated with the development of asthma in 5- and 10-year follow-up investigations (n = 3228). Dampness in Buildings and Health Study (DBH Study) commenced in 2000 in Värmland, Sweden. The current analyses included subjects who answered all baseline and follow-up questionnaires. Logistic regression analyses were applied to questionnaire results. Children who had PVC floorings in the bedroom at baseline were more likely to develop doctor-diagnosed asthma during the following 10-year period when compared with children living without. There were indications that PVC flooring in the parents' bedrooms was strongly associated with the new cases of doctor-diagnosed asthma when compared with child's bedroom. Our results suggest that PVC flooring exposure during pregnancy could be a critical period in the development of asthma in children at a later time; prenatal exposure and measurements of phthalate metabolites should be included in the future. This study has found that PVC flooring material in early life was related to incidence of asthma during the following 10 years when compared with other flooring materials and especially when comparing with wood flooring type.The study has further indicated that PVC flooring in the parents’ bedroom (proxy for prenatal exposure) was more associated with the development of asthma than PVC in the child’s bedroom was. Our results suggest that PVC flooring exposure during pregnancy could be a critical period in the development of asthma in children at a later time. In future prospective cohort study, prenatal exposure and measurements of

  18. Experimental perforation of tubing with a hydraulic sand jet

    Energy Technology Data Exchange (ETDEWEB)

    Semenov, Yu V

    1970-01-01

    A series of field tests has shown that perforation with a hydraulic sand jet improves the quality of well completion. The sand jet does not crack the cement sheath or the casing, and the perforations are larger and deeper than perforations formed by explosive charges. Fluid circulation during sand jet perforation can safely be stopped for at least 10 min. Water containing a surfactant can be used as a sand carrier. Sand jet perforation allows successful completion of wells cased by 2 tubing strings. Sand jet perforation can be used to clean the borehole well and to remove foreign objects from the well.

  19. Perforated Sigmoid Diverticular Disease: a Management Protocol

    Science.gov (United States)

    Moin, Thajammul

    2008-01-01

    Background: To develop an evidence-based protocol for the management of perforated sigmoid diverticular disease. Methods: A search of the literature was undertaken. All publications pertaining to perforated sigmoid diverticular disease were analyzed and then categorized according to their level of evidence. Recommendations were then made on the basis of this. Results: Multiple case reports suggest that primary closure of perforation of sigmoid diverticula is safe in the absence of peritoneal contamination. Conclusions: A 2-stage laparoscopic approach incorporating the principles of damage limitation surgery may be a safe strategy in the management of perforated diverticular disease. PMID:18435896

  20. Perforator anatomy of the ulnar forearm fasciocutaneous flap.

    Science.gov (United States)

    Mathy, Jon A; Moaveni, Zachary; Tan, Swee T

    2012-08-01

    The ulnar forearm fasciocutaneous flap (UFFF) is a favourable alternative to the radial forearm flap when thin and pliable tissue is required. The precise anatomy of the cutaneous perforators of UFFF has not been previously reported. The position of cutaneous perforators>0.5 mm was recorded while raising 52 consecutive free UFFFs in 51 patients at our Centre. Three (6%) UFFFs in two patients demonstrated direct cutaneous supply through a superficial ulnar artery, a known anatomic variance. There was no cutaneous perforator>0.5 mm in one flap. Among the remaining 48 dissections, an average of 3 (range, 1-6) cutaneous perforators were identified. Ninety-four percent of these forearms demonstrated at least one perforator>0.5 mm within 3 cm, and all had at least one perforator within 6 cm of the midpoint of the forearm. Proximal perforators were more likely to be musculo-cutaneous through the edge of flexor carpi ulnaris or flexor digitorum superficialis, while mid- to distal perforators were septo-cutaneous. UFFF skin paddle designed to overlie an area within 3 cm of the midpoint between the medial epicondyle and the pisiform is most likely to include at least one cutaneous perforator from the ulnar artery, without a need for intra-operative skin island adjustment. This novel anatomic finding and other practical generalisations are discussed to facilitate successful elevation of UFFF. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Perforated gastric carcinoma in a young-age patient

    Directory of Open Access Journals (Sweden)

    Feng-Hsu Wu

    2018-06-01

    Full Text Available Perforation is a rare complication of gastric carcinoma, and it occurs in less than 5% of all gastric carcinoma cases and in less than 1% within all acute abdomen cases. The diagnosis of malignancy is usually not validated preoperatively. In previous reported English literature, all patients with perforated gastric cancer have the feature of old age. This feature might be able to guide the surgeon to impress the differential diagnosis of malignancy before or during the emergent operation of gastric perforation.This 32-year-old male patient suffered from sudden onset of epigastric pain. We performed emergent operation under the impression of hollow organ perforation. The postoperative pathologic report of gastric ulcer revealed gastric carcinoma. We performed second-stage operation of total gastrectomy with D2 lymphadenectomy smoothly 7 days later. As we know, this is the youngest patient having the condition of perforated gastric carcinoma reported in the literature. This case reminds us that it is possible for perforated gastric carcinoma to occur in young-age patients. Keywords: Gastric cancer, Acute abdomen, Gastric perforation

  2. PERFORATED PEPTIC ULCER: A CLINICAL ANALYSIS AND OUTCOME

    OpenAIRE

    Bijit

    2016-01-01

    BACKGROUND The incidence of perforated peptic ulcer is approximately 7-10 cases per one lakh population per year. Perforation is seen in about 7% of patients hospitalized for peptic ulcer disease. Peptic ulcer perforation, which can be gastric/duodenal perforation can be a serious life-threatening condition if not detected early and treated urgently. Peptic ulcer disease has decreased considerably worldwide with the advent of potent anti-ulcer medicines, but its complication l...

  3. Synthesis and characterization of Zn-doped MgAl-layered double hydroxide nanoparticles as PVC heat stabilizer

    International Nuclear Information System (INIS)

    Wang, Gongling; Yang, Mei; Li, Zhiwen; Lin, Kaifeng; Jin, Quan; Xing, Chaojian; Hu, Zhudong; Wang, Dan

    2013-01-01

    Zn-doped MgAl-layered double hydroxides (LDHs) with M 2+ /M 3+ = 2 and different molar ratios of Mg/Zn have been synthesized by modified homogeneous co-precipitation method and characterized by powder X-ray diffraction, Transmission electron microscopy, Fourier transform infrared spectrum and thermogravimetry, and differential thermal analysis techniques. The thermal stabilizing effects of different LDHs on PVC were studied by Congo red test and thermal aging test. All of the nanoparticles show plate-like morphology and the average diameter of particles is around 90 nm. Results show that the introduction of Zn increased the average bond length and area of the layers of LDHs, therefore enhanced the adsorption ability on HCl gas which was generated during degradation of PVC to improve the thermal stability of PVC. LDHs with molar ratio of Mg/Zn = 1.0 shows the best thermal stabilizing effect on PVC

  4. Synthesis and characterization of Zn-doped MgAl-layered double hydroxide nanoparticles as PVC heat stabilizer

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Gongling; Yang, Mei [Chinese Academy of Sciences, State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering (China); Li, Zhiwen; Lin, Kaifeng [Harbin Institute of Technology, Academy of Fundamental Interdisciplinary Sciences (China); Jin, Quan; Xing, Chaojian; Hu, Zhudong [Chinese Academy of Sciences, State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering (China); Wang, Dan, E-mail: danwang@mail.ipe.ac.cn [Harbin Institute of Technology, Academy of Fundamental Interdisciplinary Sciences (China)

    2013-09-15

    Zn-doped MgAl-layered double hydroxides (LDHs) with M{sup 2+}/M{sup 3+} = 2 and different molar ratios of Mg/Zn have been synthesized by modified homogeneous co-precipitation method and characterized by powder X-ray diffraction, Transmission electron microscopy, Fourier transform infrared spectrum and thermogravimetry, and differential thermal analysis techniques. The thermal stabilizing effects of different LDHs on PVC were studied by Congo red test and thermal aging test. All of the nanoparticles show plate-like morphology and the average diameter of particles is around 90 nm. Results show that the introduction of Zn increased the average bond length and area of the layers of LDHs, therefore enhanced the adsorption ability on HCl gas which was generated during degradation of PVC to improve the thermal stability of PVC. LDHs with molar ratio of Mg/Zn = 1.0 shows the best thermal stabilizing effect on PVC.

  5. Perforated membrane-type acoustic metamaterials

    International Nuclear Information System (INIS)

    Langfeldt, F.; Kemsies, H.; Gleine, W.; Estorff, O. von

    2017-01-01

    This letter introduces a modified design of membrane-type acoustic metamaterials (MAMs) with a ring mass and a perforation so that an airflow through the membrane is enabled. Simplified analytical investigations of the perforated MAM (PMAM) indicate that the perforation introduces a second anti-resonance, where the effective surface mass density of the PMAM is much higher than the static value. The theoretical results are validated using impedance tube measurements, indicating good agreement between the theoretical predictions and the measured data. The anti-resonances yield high low-frequency sound transmission loss values with peak values over 25 dB higher than the corresponding mass-law. - Highlights: • A new membrane-type acoustic metamaterial exhibiting negative density is presented. • The metamaterial design contains a ring mass with a perforation through the membrane. • The sound transmission loss exhibits narrow-band peaks much higher than the mass-law. • The emergence of the peaks is explained using a simple theoretical model. • Impedance tube measurements are used to validate the theoretical predictions.

  6. Perforated membrane-type acoustic metamaterials

    Energy Technology Data Exchange (ETDEWEB)

    Langfeldt, F., E-mail: Felix.Langfeldt@haw-hamburg.de [Department of Automotive and Aeronautical Engineering, Hamburg University of Applied Sciences, Berliner Tor 9, D-20099 Hamburg (Germany); Kemsies, H., E-mail: Hannes.Kemsies@haw-hamburg.de [Department of Automotive and Aeronautical Engineering, Hamburg University of Applied Sciences, Berliner Tor 9, D-20099 Hamburg (Germany); Gleine, W., E-mail: Wolfgang.Gleine@haw-hamburg.de [Department of Automotive and Aeronautical Engineering, Hamburg University of Applied Sciences, Berliner Tor 9, D-20099 Hamburg (Germany); Estorff, O. von, E-mail: estorff@tu-harburg.de [Institute of Modelling and Computation, Hamburg University of Technology, Denickestr. 17, D-21073 Hamburg (Germany)

    2017-04-25

    This letter introduces a modified design of membrane-type acoustic metamaterials (MAMs) with a ring mass and a perforation so that an airflow through the membrane is enabled. Simplified analytical investigations of the perforated MAM (PMAM) indicate that the perforation introduces a second anti-resonance, where the effective surface mass density of the PMAM is much higher than the static value. The theoretical results are validated using impedance tube measurements, indicating good agreement between the theoretical predictions and the measured data. The anti-resonances yield high low-frequency sound transmission loss values with peak values over 25 dB higher than the corresponding mass-law. - Highlights: • A new membrane-type acoustic metamaterial exhibiting negative density is presented. • The metamaterial design contains a ring mass with a perforation through the membrane. • The sound transmission loss exhibits narrow-band peaks much higher than the mass-law. • The emergence of the peaks is explained using a simple theoretical model. • Impedance tube measurements are used to validate the theoretical predictions.

  7. Thermal stability of formulations of PVC irradiated with γ of 60

    International Nuclear Information System (INIS)

    Martinez P, M.E.; Carrasco A, H.; Castaneda F, A.; Benavides C, R.; Garcia R, S.P.

    2004-01-01

    The industry of cables and wires frequently use cable isolations with base of formulations of PVC, in those that stabilizer has usually been used with the help of heavy metals, as the lead, which is toxic. To solve the problem, from the 2002 one has come studying in combined form in the National Institute of Nuclear Research ININ and the Center of Investigation in Applied Chemistry CIQA, the modifications induced by the radiation in formulations with the help of vinyl poly chloride PVC. In these formulations, prepared with cross linking agent, plastifying industrial grade, stuff and non toxic stabilizers of calcium estearate and zinc industrial grade, it is sought to replace the stabilizer of Pb. For this were irradiated it test tubes of PVC with gamma radiation of cobalt 60 to three different dose in atmospheres of air and argon. Later it was determined their thermal stability at different times of heating and it was measured the Young modulus by means of thermo mechanical analysis. Those results obtained together with other techniques of characterization suggest that the irradiated proposed formulation can substitute the one stabilized with lead. (Author)

  8. Oriented cluster perforating technology and its application in horizontal wells

    Directory of Open Access Journals (Sweden)

    Huabin Chen

    2016-11-01

    Full Text Available An oriented cluster perforating technology, which integrates both advantages of cluster and oriented perforating, will help solve a series of technical complexities in horizontal well drilling. For realizing its better application in oil and gas development, a series of technologies were developed including perforator self-weight eccentricity, matching of the electronic selective module codes with the surface program control, axial centralized contact signal transmission, and post-perforation intercluster sealing insulation. In this way, the following functions could be realized, such as cable-transmission horizontal well perforator self-weight orientation, dynamic signal transmission, reliable addressing & selective perforation and post-perforation intercluster sealing. The combined perforation and bridge plug or the multi-cluster perforation can be fulfilled in one trip of perforation string. As a result, the horizontal-well oriented cluster perforating technology based on cable conveying was developed. This technology was successfully applied in unconventional gas reservoir exploitation, such as shale gas and coalbed methane, with accurate orientation, reliable selective perforation and satisfactory inter-cluster sealing. The horizontal-well oriented cluster perforating technology benefits the orientation of horizontal well drilling with a definite target and direction, which provides a powerful support for the subsequent reservoir stimulation. It also promotes the fracturing fluid to sweep the principal pay zones to the maximum extent. Moreover, it is conductive to the formation of complex fracture networks in the reservoirs, making quality and efficient development of unconventional gas reservoirs possible.

  9. Platelet storage in Fresenius/NPBI polyolefin and BTHC-PVC bags: a direct comparison.

    Science.gov (United States)

    Hornsey, V S; McColl, K; Drummond, O; Macgregor, I R; Prowse, C V

    2008-08-01

    New platelet storage systems, such as changes in the plastic of the storage bags, require validation. In this study, pooled buffy coat platelets stored in Fresenius/NPBI polyolefin bags were compared with those stored in Fresenius/NPBI butyryl-trihexyl citrate (BTHC) plasticized polyvinyl chloride (PVC). The CompoSelect thrombocyte polishing filter system (1000 mL polyolefin bag) and the CompoStop F730 system (1300 mL BTHC-PVC bag) were used to prepare paired, plasma-suspended, buffy coat platelet concentrates. Samples were taken up to day 7 for in vitro analysis. In a separate experiment, 12 units were prepared using the CompoStop F730 system and samples taken after leucofiltration for FXIIa assay. By day 7, platelet concentrates stored in BTHC-PVC demonstrated significantly higher pH levels (7.32 +/- 0.05 vs. 7.26 +/- 0.05) and a greater degree of cell lysis as shown by increased lactate dehydrogenase levels (497 +/- 107 vs. 392 +/- 81 U L(-1)). The supernatants contained higher concentrations of soluble P-selectin and the chemokine 'regulated on activation, normal T-cell expressed and presumably secreted', which are released from the alpha-granules during activation. The ATP concentrations were significantly lower in BTHC-PVC. Platelet counts, mean platelet volume and hypotonic shock response were similar for both bags. FXIIa antigen concentrations were 0.6 +/- 0.2 ng mL(-1) indicating that activation of the contact factor pathway had not occurred. Although the CompoStop F730 leucoreduction filter did not activate the contact system, platelets stored in 100% plasma in BTHC-PVC bags demonstrated different in vitro characteristics from those stored in polyolefin. Further work is required to demonstrate whether these differences will affect in vivo recovery and survival.

  10. The value of CT in detecting pathologic bowel perforation

    International Nuclear Information System (INIS)

    Chang, Jong Wun; Shin, Joo Yong; Kim, Hong; Rhee, Chang Soo; Lee, Sung Moon; Joo, Yang Goo; Suh, Soo Jhi

    1997-01-01

    To evaluate the usefulness of CT for assessing the location and cause of pathologic gastrointestinal perforation. A retrospective analysis of abdominal CT was performed in 27 perforations of 26 patients with underlying gastrointestinal pathology. Fifteen benign and 12 malignant perforations consisted of five gastric cancers, one gastric ulcer, ten duodenal bulb ulcers. two bowel adhesions, one jejunal metastasis from lung cancer, one ileocolic Crohn's disease, one radiation colitis and six colon cancers. CT scans were evaluated for 1) diagnosis of bowel perforation, 2) assessment of the cause and site of perforation, and, in particular, differentiation between benignancy and malignancy, and 3) complications and their extent. CT easily detected varying amounts of free air or fluid collection, and infiltration or abscess formation adjacent to the main lesion, and the diagnosis of gastrointestinal perforation was therefore easy. In 11 of the 12 malignancies (92%), primary tumor was diagnosed, but detection of the site of perforation was possible in only seven cases(7/12, 58%). The 15 benign lesions revealed nonspecific CT findings, and the perforation site could be presumed in six (6/15, 40%). In one case of Crohn's disease, the primary cause was visualized. Among six colonic cancers, four pericolic abscesses and two fistulas to adjacent organs were found, but there was no evidence of diffuse peritonitis. CT was helpful to lead to optimal treatment of pathologic gastrointestinal On CT the detectability of perforation, primary benign or malignant lesion, perforation site and extent of complication was high, and this modality was therefore a useful indicator of the optimal treatment for pathologic gastrointestinal perforations.=20

  11. Investigation of dielectric behavior of the PVC/BaTiO3 composite in low-frequencies

    Science.gov (United States)

    Berrag, A.; Belkhiat, S.; Madani, L.

    2018-04-01

    Polyvinyl chloride (PVC) is widely used as insulator in electrical engineering especially as cable insulation sheaths. In order to improve the dielectric properties, polymers are mixed with ceramics. In this paper, PVC composites with different weight percentages 2 wt.%, 5 wt.%, 8 wt.% and 10 wt.% were prepared and investigated. Loss index (𝜀″) and dielectric constant (𝜀‧) have been measured using an impedance analyzer RLC. Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) equipped with energy dispersive X-ray (EDX) have been used as characterization techniques. The incorporation of BaTiO3 does not modify the crystallinity and the morphology of the PVC but reduces the space charges, therefore the dielectric losses. The frequency response analysis has been followed in the frequency ranges (20-140 Hz and 115-1 MHz). Relaxation frequencies have been evaluated in each frequency range. Experimental measurements have been validated using Cole-Cole’s model. Experimental results show well that BaTiO3 as a filler improves the dielectric properties of PVC.

  12. Duodenal perforation during percutaneous nephrolithotomy (PCNL ...

    African Journals Online (AJOL)

    A. Bansal

    2016-06-03

    Jun 3, 2016 ... Calculus;. Duodenum;. Injury;. Paediatric;. Percutaneous nephrolithotomy. Abstract. Introduction: Colonic perforations are known complications of percutaneous nephrolithotomy (PCNL). However, to the best of our knowledge, small bowel perforation has rarely been reported.. Observation: We report the ...

  13. External perforated window Solar Screens: The effect of screen depth and perforation ratio on energy performance in extreme desert environments

    KAUST Repository

    Sherif, A.

    2012-09-01

    In hot arid desert environments, the solar radiation passing through windows increases the cooling loads and the energy consumption of buildings. Shading of windows can reduce these loads. Unlike the woven solar screens, wooden solar screens have a thickness that provides selective shading properties. Perforated wooden solar screens were traditionally used for windows shading. Developing modern types of these shading systems can lead to significant energy savings. The paper addresses the influence of changing the perforation percentage and depth of these screens on the annual energy loads, hence defining the optimum depth/perforation configurations for various window orientations. Series of experiments were performed using the EnergyPlus simulation software for a typical residential building in the Kharga Oasis, located in the Egyptian desert. A range of perforation percentages and depths were tested. Conclusions prove that external fixed deep perforated solar screens could effectively achieve energy savings up to 30% of the total energy consumption in the West and South orientations. Optimum range of depths and perforation percentages were recommended. These are: 80-90% perforation rate and 1:1 depth/opening width ratio. These lighter and deeper solar screen configurations were found to be more efficient in energy consumption in comparison with the traditional ones. © 2012 Elsevier B.V. All rights reserved.

  14. Intestinal perforation by an ingested foreign body*

    Science.gov (United States)

    Nicolodi, Gabriel Cleve; Trippia, Cesar Rodrigo; Caboclo, Maria Fernanda F. S.; de Castro, Francisco Gomes; Miller, Wagner Peitl; de Lima, Raphael Rodrigues; Tazima, Leandro; Geraldo, Jamylle

    2016-01-01

    Objective To identify the computed tomography findings suggestive of intestinal perforation by an ingested foreign body. Materials and Methods This was a retrospective study of four cases of surgically proven intestinal perforation by a foreign body, comparing the computed tomography findings with those described in the literature. Results None of the patients reported having ingested a foreign body, all were over 60 years of age, three of the four patients used a dental prosthesis, and all of the foreign bodies were elongated and sharp. In all four patients, there were findings indicative of acute abdomen. None of the foreign bodies were identified on conventional X-rays. The computed tomography findings suggestive of perforation were thickening of the intestinal walls (in all four cases), increased density of mesenteric fat (in all four cases), identification of the foreign body passing through the intestinal wall (in three cases), and gas in the peritoneal cavity (in one case). Conclusion In cases of foreign body ingestion, intestinal perforation is more common when the foreign body is elongated and sharp. Although patients typically do not report having ingested such foreign bodies, the scenario should be suspected in elderly individuals who use dental prostheses. A computed tomography scan can detect foreign bodies, locate perforations, and guide treatment. The findings that suggest perforation are thickening of the intestinal walls, increased mesenteric fat density, and, less frequently, gas in the peritoneal cavity, often restricted to the point of perforation. PMID:27818542

  15. Intestinal perforation by an ingested foreign body

    International Nuclear Information System (INIS)

    Nicolodi, Gabriel Cleve; Trippia, Cesar Rodrigo; Caboclo, Maria Fernanda F.S.; Castro, Francisco Gomes de; Miller, Wagner Peitl; Lima, Raphael Rodrigues de; Tazima, Leandro; Geraldo, Jamylle

    2016-01-01

    Objective: To identify the computed tomography findings suggestive of intestinal perforation by an ingested foreign body. Materials and Methods: This was a retrospective study of four cases of surgically proven intestinal perforation by a foreign body, comparing the computed tomography findings with those described in the literature. Results: None of the patients reported having ingested a foreign body, all were over 60 years of age, three of the four patients used a dental prosthesis, and all of the foreign bodies were elongated and sharp. In all four patients, there were findings indicative of acute abdomen. None of the foreign bodies were identified on conventional X-rays. The computed tomography findings suggestive of perforation were thickening of the intestinal walls (in all four cases), increased density of mesenteric fat (in all four cases), identification of the foreign body passing through the intestinal wall (in three cases), and gas in the peritoneal cavity (in one case). Conclusion: In cases of foreign body ingestion, intestinal perforation is more common when the foreign body is elongated and sharp. Although patients typically do not report having ingested such foreign bodies, the scenario should be suspected in elderly individuals who use dental prostheses. A computed tomography scan can detect foreign bodies, locate perforations, and guide treatment. The findings that suggest perforation are thickening of the intestinal walls, increased mesenteric fat density, and, less frequently, gas in the peritoneal cavity, often restricted to the point of perforation. (author)

  16. Intestinal perforation by an ingested foreign body.

    Science.gov (United States)

    Nicolodi, Gabriel Cleve; Trippia, Cesar Rodrigo; Caboclo, Maria Fernanda F S; de Castro, Francisco Gomes; Miller, Wagner Peitl; de Lima, Raphael Rodrigues; Tazima, Leandro; Geraldo, Jamylle

    2016-01-01

    To identify the computed tomography findings suggestive of intestinal perforation by an ingested foreign body. This was a retrospective study of four cases of surgically proven intestinal perforation by a foreign body, comparing the computed tomography findings with those described in the literature. None of the patients reported having ingested a foreign body, all were over 60 years of age, three of the four patients used a dental prosthesis, and all of the foreign bodies were elongated and sharp. In all four patients, there were findings indicative of acute abdomen. None of the foreign bodies were identified on conventional X-rays. The computed tomography findings suggestive of perforation were thickening of the intestinal walls (in all four cases), increased density of mesenteric fat (in all four cases), identification of the foreign body passing through the intestinal wall (in three cases), and gas in the peritoneal cavity (in one case). In cases of foreign body ingestion, intestinal perforation is more common when the foreign body is elongated and sharp. Although patients typically do not report having ingested such foreign bodies, the scenario should be suspected in elderly individuals who use dental prostheses. A computed tomography scan can detect foreign bodies, locate perforations, and guide treatment. The findings that suggest perforation are thickening of the intestinal walls, increased mesenteric fat density, and, less frequently, gas in the peritoneal cavity, often restricted to the point of perforation.

  17. Intestinal perforation by an ingested foreign body

    Energy Technology Data Exchange (ETDEWEB)

    Nicolodi, Gabriel Cleve; Trippia, Cesar Rodrigo; Caboclo, Maria Fernanda F.S.; Castro, Francisco Gomes de; Miller, Wagner Peitl; Lima, Raphael Rodrigues de; Tazima, Leandro; Geraldo, Jamylle, E-mail: gabrielnicolodi@gmail.com [Hospital Sao Vicente - Funef, Curitiba, PR (Brazil)

    2016-09-15

    Objective: To identify the computed tomography findings suggestive of intestinal perforation by an ingested foreign body. Materials and Methods: This was a retrospective study of four cases of surgically proven intestinal perforation by a foreign body, comparing the computed tomography findings with those described in the literature. Results: None of the patients reported having ingested a foreign body, all were over 60 years of age, three of the four patients used a dental prosthesis, and all of the foreign bodies were elongated and sharp. In all four patients, there were findings indicative of acute abdomen. None of the foreign bodies were identified on conventional X-rays. The computed tomography findings suggestive of perforation were thickening of the intestinal walls (in all four cases), increased density of mesenteric fat (in all four cases), identification of the foreign body passing through the intestinal wall (in three cases), and gas in the peritoneal cavity (in one case). Conclusion: In cases of foreign body ingestion, intestinal perforation is more common when the foreign body is elongated and sharp. Although patients typically do not report having ingested such foreign bodies, the scenario should be suspected in elderly individuals who use dental prostheses. A computed tomography scan can detect foreign bodies, locate perforations, and guide treatment. The findings that suggest perforation are thickening of the intestinal walls, increased mesenteric fat density, and, less frequently, gas in the peritoneal cavity, often restricted to the point of perforation. (author)

  18. Intestinal perforation by an ingested foreign body

    Directory of Open Access Journals (Sweden)

    Gabriel Cleve Nicolodi

    Full Text Available Abstract Objective: To identify the computed tomography findings suggestive of intestinal perforation by an ingested foreign body. Materials and Methods: This was a retrospective study of four cases of surgically proven intestinal perforation by a foreign body, comparing the computed tomography findings with those described in the literature. Results: None of the patients reported having ingested a foreign body, all were over 60 years of age, three of the four patients used a dental prosthesis, and all of the foreign bodies were elongated and sharp. In all four patients, there were findings indicative of acute abdomen. None of the foreign bodies were identified on conventional X-rays. The computed tomography findings suggestive of perforation were thickening of the intestinal walls (in all four cases, increased density of mesenteric fat (in all four cases, identification of the foreign body passing through the intestinal wall (in three cases, and gas in the peritoneal cavity (in one case. Conclusion: In cases of foreign body ingestion, intestinal perforation is more common when the foreign body is elongated and sharp. Although patients typically do not report having ingested such foreign bodies, the scenario should be suspected in elderly individuals who use dental prostheses. A computed tomography scan can detect foreign bodies, locate perforations, and guide treatment. The findings that suggest perforation are thickening of the intestinal walls, increased mesenteric fat density, and, less frequently, gas in the peritoneal cavity, often restricted to the point of perforation.

  19. Neurodevelopmental outcome after neonatal perforator stroke

    NARCIS (Netherlands)

    Ecury-Goossen, Ginette M; van der Haer, Marit; Smit, Liesbeth S; Feijen-Roon, Monique; Lequin, Maarten; de Jonge, Rogier C J; Govaert, Paul; Dudink, Jeroen

    AIM: To assess outcome after neonatal perforator stroke in the largest cohort to date. METHOD: Survivors from a cohort of children diagnosed with neonatal perforator stroke using cranial ultrasound or magnetic resonance imaging were eligible for inclusion. Recovery and Recurrence Questionnaire

  20. In vitro quality of apheresis platelets divided into paediatric-sized units and stored in PVC bags plasticised with TOTM, BTHC or DINCH.

    Science.gov (United States)

    Bashir, S; Meli, A; Cardigan, R

    2018-04-11

    Two of the predictive factors of the quality of small volumes of platelets suitable for paediatric use are bag size and material. This study evaluated the storage properties of paediatric platelet aliquots in TOTM-, BTHC- or DINCH-PVC bags. (i) Three apheresis platelet concentrates (PC) were pooled and split into three units. One was retained as an adult unit (control; polyolefin bag). The second and third units were split into four MacoPharma TOTM-PVC and BTHC-PVC paediatric bags, respectively. (ii) Two apheresis PC were pooled and split into two units. One PC was retained as an adult unit, and the other was split into four Fresenius DINCH-PVC paediatric bags. Testing was performed on storage for pH, blood gases, hypotonic shock response, soluble CD62P, LDH, glucose and lactate, ATP, CD62P, CD63, platelet-derived microparticles and annexin V. The volumes, platelet yields and pH of all paediatric units met local specifications. The TOTM-PVC bag showed no worse quality than the adult bag up to day 7 for all parameters studied, and it maintained pH higher than BTHC-PVC and DINCH-PVC over storage. The BTHC-PVC bag was shown to be the most gas permeable; however, it had the highest glucose consumption rates and the highest platelet activation. All bags showed an acceptable in vitro quality. Overall, the TOTM-PVC paediatric bag showed better platelet quality compared to the other storage bags, whereas storage in the BTHC-PVC bag resulted in poorer platelet quality. © 2018 British Blood Transfusion Society.

  1. Aging and characterization of PVC compound used as flat-panel of a low cost solar collector; Envelhecimento e caracterizacao de compostos de PVC usado em placas de coletores solares de baixo custo

    Energy Technology Data Exchange (ETDEWEB)

    Prado, Bruna R.; Pinto, Tatiana T.; Bartoli, Julio R. [Depto. de Tecnologia de Polimeros, Faculdade de Engenharia Quimica/Universidade Estadual de Campinas. FEQ/UNICAMP, SP (Brazil)], e-mail: bartoli@feq.unicamp.br; Fernandes, Elizabeth G. [Tezca P and D Celulas Solares (Brazil)

    2011-07-01

    Regardless the excellent amount of solar irradiation in Brazil, the development and production of solar water heating systems did not reach the low-income families yet. The relatively high cost of conventional solar water heaters is still the main reason to prevent it. The development of a low cost solar water heater (around US$ 200), easy technology, was the scope of previous work. All-plastic solar collector prototypes were developed using unplasticized Poly (vinyl chloride) ceiling panels and tubes, commodities from building engineering. Nevertheless, the main thermal and photo degradation mechanisms for PVC are well known; the unusual application of PVC as solar collector materials should need a specific investigation on environmental aging. This work presents a study on outdoor aging and characterization of PVC flat-plate absorber of solar collectors after 5 years on use. (author)

  2. Duodenal perforation: an unusual complication of sickle cell anemia.

    Science.gov (United States)

    Acıpayam, Can; Aldıç, Güliz; Akçora, Bülent; Çelikkaya, Mehmet Emin; Aşkar, Hasan; Dorum, Bayram Ali

    2014-01-01

    Duodenal perforation in childhood is a rare condition with a high mortality rate if not treated surgically. Primary gastroduodenal perforation is frequently associated with peptic ulcer and exhibits a positive family history. Helicobacter pylorus is the most significant agent. Secondary gastroduodenal perforation may be a finding of specific diseases, such as Crohn disease, or more rarely may be associated with diseases such as cystic fibrosis or sickle cell anemia. A 14-year-old boy presented with abdominal and back pain. The patient was operated on for acute abdomen and diagnosed with duodenal perforation. Helicobacter pylorus was negative. There was no risk factor to account for duodenal perforation other than sickle cell anemia. Surgical intervention was successful and without significant sequelae. Duodenal perforation is a rare entity described in patients with sickle cell anemia. To our knowledge, this is the first report of duodenal perforation in a patient sickle cell anemia.

  3. Spectroscopic analysis of PMMA/PVC blends containing CoCl2

    Directory of Open Access Journals (Sweden)

    N.S. Alghunaim

    2015-01-01

    Full Text Available Composites of polymethyl methacrylate (PMMA and polyvinyl chloride (PVC polymer blend containing different concentrations (⩽10 wt. of cobalt chloride (CoCl2 were prepared by casting techniques. The changes of the structural, spectroscopic, optical and thermal parameters of the samples are studied using different tools. FT-IR spectroscopy confirmed the complexation between the blends and Co+2-ions. The decrease or increase of IR band intensity with some shifts of other bands suggests an interaction and compatibility between PMMA/PVC blends with CoCl2 take place. The Ultra violet and visible (UV/Vis spectra indicated that the presence of band gap energy depends on increasing of CoCl2 contents. The absorption intensity of the samples doped with CoCl2 becomes faint lower than the pure blend. The values of energy gap for direct and indirect transition decreases with the increase of CoCl2 due to the presence of charge transfer between PMMA/PVC and CoCl2. The thermogravimetric analysis (TGA curves for all the samples have the same behavior and more steps of decomposition were observed. The reduction of mass loss for samples containing CoCl2 compared to the pure blend was observed and it was attributed to crosslink formation between the blend and CoCl2.

  4. Selective flotation of PVC using gelatin and lignin alkali.

    Science.gov (United States)

    Yenial, Unzile; Kangal, Olgaç; Güney, Ali

    2013-06-01

    Recycling has become one of the most important issues as a result of increasing waste mass in present day. This is especially important for polymer wastes as they are hard to degenerate in nature. Today, most of the practical methods used for the recycling of waste mass, such as hand sorting, gravity separation, etc., cannot be performed successfully owing to close densities of polymers. Froth flotation can be used successfully and economically for this purpose. The main objective of this study was to investigate the effect of plasticizer reagents and the success of froth flotation at plastic recycling. In this study, lignin alkali and gelatin were used as plasticizer reagents. The effect of these reagents was searched with the parameters of pH, concentration, conditioning and flotation time. In the case of post-consumed polyethylene terephthalate and polyvinyl chloride (PVC), 98.9% purity of PVC was obtained at optimum conditions.

  5. The value of CT in detecting pathologic bowel perforation

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Jong Wun; Shin, Joo Yong; Kim, Hong; Rhee, Chang Soo; Lee, Sung Moon; Joo, Yang Goo; Suh, Soo Jhi [Keimyung Univ. School of Medicine, Taegu (Korea, Republic of)

    1997-10-01

    To evaluate the usefulness of CT for assessing the location and cause of pathologic gastrointestinal perforation. A retrospective analysis of abdominal CT was performed in 27 perforations of 26 patients with underlying gastrointestinal pathology. Fifteen benign and 12 malignant perforations consisted of five gastric cancers, one gastric ulcer, ten duodenal bulb ulcers. two bowel adhesions, one jejunal metastasis from lung cancer, one ileocolic Crohn's disease, one radiation colitis and six colon cancers. CT scans were evaluated for (1) diagnosis of bowel perforation, (2) assessment of the cause and site of perforation, and, in particular, differentiation between benignancy and malignancy, and (3) complications and their extent. CT easily detected varying amounts of free air or fluid collection, and infiltration or abscess formation adjacent to the main lesion, and the diagnosis of gastrointestinal perforation was therefore easy. In 11 of the 12 malignancies (92%), primary tumor was diagnosed, but detection of the site of perforation was possible in only seven cases(7/12, 58%). The 15 benign lesions revealed nonspecific CT findings, and the perforation site could be presumed in six (6/15, 40%). In one case of Crohn's disease, the primary cause was visualized. Among six colonic cancers, four pericolic abscesses and two fistulas to adjacent organs were found, but there was no evidence of diffuse peritonitis. CT was helpful to lead to optimal treatment of pathologic gastrointestinal On CT the detectability of perforation, primary benign or malignant lesion, perforation site and extent of complication was high, and this modality was therefore a useful indicator of the optimal treatment for pathologic gastrointestinal perforations.=20.

  6. Laparoscopic treatment of perforated appendicitis

    Science.gov (United States)

    Lin, Heng-Fu; Lai, Hong-Shiee; Lai, I-Rue

    2014-01-01

    The use of laparoscopy has been established in improving perioperative and postoperative outcomes for patients with simple appendicitis. Laparoscopic appendectomy is associated with less wound pain, less wound infection, a shorter hospital stay, and faster overall recovery when compared to the open appendectomy for uncomplicated cases. In the past two decades, the use of laparoscopy for the treatment of perforated appendicitis to take the advantages of minimally invasiveness has increased. This article reviewed the prevalence, approaches, safety disclaimers, perioperative and postoperative outcomes of the laparoscopic appendectomy in the treatment of patients with perforated appendicitis. Special issues including the conversion, interval appendectomy, laparoscopic approach for elderly or obese patient are also discussed to define the role of laparoscopic treatment for patients with perforated appendicitis. PMID:25339821

  7. DETERMINATION OF THE TEMPERATURE DISTRIBUTION THE PERFORATED FINS UNDER

    Directory of Open Access Journals (Sweden)

    Aziz7 M. Mhamuad

    2015-02-01

    Full Text Available This work treats the problem of heat transfer for perforated fins under natural convection. The temperature distribution is examined for an array of rectangular fins (15 fins with uniform cross-sectional area (100x270 mm embedded with various vertical body perforations that extend through the fin thickness. The patterns of perforations include 18 circular perforations (holes. Experiments were carried out in an experimental facility that was specifically design and constructed for this purpose. The heat transfer rate and the coefficient of heat transfer increases with perforation diameter increased. 

  8. Perforated peptic ulcer: How to improve outcome?

    DEFF Research Database (Denmark)

    Møller, Morten Hylander; Adamsen, Sven; Wøjdemann, Morten

    2008-01-01

    Despite the introduction of histamine H(2)-receptor antagonists, proton-pump inhibitors and the discovery of Helicobacter pylori, both the incidence of emergency surgery for perforated peptic ulcer and the mortality rate for patients undergoing surgery for peptic ulcer perforation have increased...... with an emphasis on risks that are preventable. A systematic review including randomized studies was carried out. There are a limited number of studies of patients with peptic ulcer perforation. Most of these studies are of low evidential status. Only a few randomized, controlled trials have been published...... to improve the outcome of patients with peptic ulcer perforation, sepsis needs to be factored into the existing knowledge and treatment Udgivelsesdato: 2008/8/27...

  9. Fast track pathway for perforated appendicitis.

    Science.gov (United States)

    Frazee, Richard; Abernathy, Stephen; Davis, Matthew; Isbell, Travis; Regner, Justin; Smith, Randall

    2017-04-01

    Perforated appendicitis is associated with an increased morbidity and length of stay. "Fast track" protocols have demonstrated success in shortening hospitalization without increasing morbidity for a variety of surgical processes. This study evaluates a fast track pathway for perforated appendicitis. In 2013, a treatment pathway for perforated appendicitis was adopted by the Acute Care Surgery Service for patients having surgical management of perforated appendicitis. Interval appendectomy was excluded. Patients were treated initially with intravenous antibiotics and transitioned to oral antibiotics and dismissed when medically stable and tolerating oral intake. A retrospective review of patients managed on the fast track pathway was undertaken to analyze length of stay, morbidity, and readmissions. Thirty-four males and twenty-one females with an average age of 46.8 years underwent laparoscopic appendectomy for perforated appendicitis between January 2013 and December 2014. Pre-existing comorbidities included hypertension 42%, diabetes mellitus 11%, COPD 5% and heart disease 2%. No patient had conversion to open appendectomy. Average length of stay was 2.67 days and ranged from 1 to 12 days (median 2 days). Postoperative morbidity was 20% and included abscess (6 patients), prolonged ileus (3 patients), pneumonia (1 patient), and congestive heart failure (1 patient). Five patients were readmitted for abscess (3 patients), congestive heart failure (1 patient), and pneumonia (1 patient). A fast track pathway for perforated appendicitis produced shorter length of stay and acceptable postoperative morbidity and readmission. This offers the potential for significant cost savings over current national practice patterns. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Effect of radiation on properties of ENR/PVC/SiO{sub 2} membrane

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, Nur Farahein Hadina; Abdullah, Ibrahim; Daik, Rusli; Ahmad, Ishak; Jamil, Suzereen; Lazim, Mohammad Azwan Mat; Othaman, Rizafizah [School of Chemical Sciences and Food Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor Darul Ehsan. Malaysia (Malaysia)

    2015-09-25

    In this study epoxidised natural rubber (ENR)/polyvinyl chloride (PVC) matrix was prepared by melt blending. The matrix was swelled in THF and silica as a filler was introduced to the solution to generate pore formation. The ENR/PVC/10 % SiO{sub 2} membrane was prepared using a casting knife technique. The membrane was irradiated using 2 MeV electron beam accelerator at a dose range of 10-100 kGy. The effect of electron beam irradiation of the membrane was studied by undergo characterization of Scanning electron microscope (SEM) and Fourier transform infra red (FTIR). Morphological studies showed that pores generated in ENR/PVC/10 % SiO{sub 2} membrane increased with the dosage of radiation. While FTIR analysis showed the presence of peak of Si-O-Si asymmetric stretching at 834 cm{sup −1}. There are no significant changes in the functional group before and after radiation.

  11. Forensic utility of the carbon isotope ratio of PVC tape backings

    Science.gov (United States)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  12. The Heidelberg Appendicitis Score Predicts Perforated Appendicitis in Children.

    Science.gov (United States)

    Boettcher, Michael; Günther, Patrick; Breil, Thomas

    2017-10-01

    In the future, surgical management of pediatric appendicitis might become limited to nonperforating appendicitis. Thus, it becomes increasingly important to differentiate advanced from simple appendicitis and to predict perforated appendicitis among a group of children with right-sided abdominal pain, which was the aim of this study. An institutionally approved, single-center retrospective analysis of all patients with appendectomy from January 2009 to December 2010 was conducted. All diagnostic aspects were evaluated to identify predictors and differentiators of perforated appendicitis. In 2 years, 157 children suffered from appendicitis. Perforation occurred in 47 (29.9%) of the patients. C-reactive protein (CRP) levels higher than 20 mg/dL ( P = .037) and free abdominal fluid on ultrasonography ( P = .031) are the most important features to differentiate perforated from simple appendicitis. Moreover, all children with perforation had a positive Heidelberg Appendicitis Score (HAS). A negative HAS excludes perforation in all cases (negative predictive value = 100%). Perforated appendicitis can be ruled out by the HAS. In a cohort with right-sided abdominal pain, perforation should be considered in children with high CRP levels and free fluids or abscess formation on ultrasound.

  13. Medicolegal aspects of iatrogenic root perforations

    DEFF Research Database (Denmark)

    Tsesis, I; Rosen, E; Bjørndal, L

    2014-01-01

    AIM: To retrospectively analyze the medico-legal aspects of iatrogenic root perforations (IRP) that occurred during endodontic treatments. METHODOLOGY: A comprehensive search in a professional liability insurance database was conducted to retrospectively identify cases of IRP following root canal...... treatment (p root perforation is a complication of root canal treatment and may result in tooth extraction...... and in legal actions against the treating practitioner. Mandibular molars are more prone to medico-legal claims related to root perforations. The patient should be informed of the risks during RCT and should get information on alternative treatments and their risks and prognosis...

  14. Spontaneous ileal perforation complicating low anorectal malformation

    Directory of Open Access Journals (Sweden)

    TiJesuni Olatunji

    2015-01-01

    Full Text Available Anorectal malformation is a common anomaly in neonates. Although colorectal perforations have been reported as a complication, ileal perforation is rarely encountered. This is a report of a 2-day-old boy presenting with a low anorectal malformation, complicated with ileal perforation, necessitating laparotomy and ileal repair. Anoplasty was done for the low anomaly. Early presentation and prompt treatment of anorectal malformations is important to prevent such potential life threatening complication.

  15. Premixed Combustion of Coconut Oil on Perforated Burner

    Directory of Open Access Journals (Sweden)

    I.K.G. Wirawan

    2013-10-01

    Full Text Available Coconut oil premixed combustion behavior has been studied experimentally on perforated burner with equivalence ratio (φ varied from very lean until very rich. The results showed that burning of glycerol needs large number of air so that the laminar burning velocity (SL is the highest at very lean mixture and the flame is in the form of individual Bunsen flame on each of the perforated plate hole. As φ is increased the  SL decreases and the secondary Bunsen flame with open tip occurs from φ =0.54 at the downstream of perforated flame. The perforated flame disappears at φ = 0.66 while the secondary Bunsen flame still exist with SL increases following that of hexadecane flame trend and then extinct when the equivalence ratio reaches one or more. Surrounding ambient air intervention makes SL decreases, shifts lower flammability limit into richer mixture, and performs triple and cellular flames. The glycerol diffusion flame radiation burned fatty acids that perform cellular islands on perforated hole.  Without glycerol, laminar flame velocity becomes higher and more stable as perforated flame at higher φ. At rich mixture the Bunsen flame becomes unstable and performs petal cellular around the cone flame front. Keywords: cellular flame; glycerol; perforated flame;secondary Bunsen flame with open tip; triple flame

  16. PVC flooring is related to human uptake of phthalates in infants.

    Science.gov (United States)

    Carlstedt, F; Jönsson, B A G; Bornehag, C-G

    2013-02-01

    Polyvinyl chloride (PVC) flooring material contains phthalates, and it has been shown that such materials are important sources for phthalates in indoor dust. Phthalates are suspected endocrine-disrupting chemicals (EDCs). Consecutive infants between 2 and 6 months old and their mothers were invited. A questionnaire about indoor environmental factors and family lifestyle was used. Urinary metabolites of the phthalates diethyl phthalate (DEP), dibutyl phthalate (DBP), butylbenzyl phthalate (BBzP), and dietylhexyl phthalate (DEHP) were measured in the urine of the children. Of 209 invited children, 110 (52%) participated. Urine samples were obtained from 83 of these. Urine levels of the BBzP metabolite monobenzyl phthalate (MBzP) was significantly higher in infants with PVC flooring in their bedrooms (P flooring material may increase the human uptake of phthalates in infants. Urinary levels of phthalate metabolites during early life are associated with the use of PVC flooring in the bedroom, body area, and the use of infant formula. This study shows that the uptake of phthalates is not only related to oral uptake from, for example, food but also to environmental factors such as building materials. This new information should be considered when designing indoor environment, especially for children. © 2012 John Wiley & Sons A/S.

  17. Microvascular anatomy of the cerebellar parafloccular perforating space.

    Science.gov (United States)

    Sosa, Pablo; Dujovny, Manuel; Onyekachi, Ibe; Sockwell, Noressia; Cremaschi, Fabián; Savastano, Luis E

    2016-02-01

    The cerebellopontine angle is a common site for tumor growth and vascular pathologies requiring surgical manipulations that jeopardize cranial nerve integrity and cerebellar and brainstem perfusion. To date, a detailed study of vessels perforating the cisternal surface of the middle cerebellar peduncle-namely, the paraflocculus or parafloccular perforating space-has yet to be published. In this report, the perforating vessels of the anterior inferior cerebellar artery (AICA) in the parafloccular space, or on the cisternal surface of the middle cerebellar peduncle, are described to elucidate their relevance pertaining to microsurgery and the different pathologies that occur at the cerebellopontine angle. Fourteen cadaveric cerebellopontine cisterns (CPCs) were studied. Anatomical dissections and analysis of the perforating arteries of the AICA and posterior inferior cerebellar artery at the parafloccular space were recorded using direct visualization by surgical microscope, optical histology, and scanning electron microscope. A comprehensive review of the English-language and Spanish-language literature was also performed, and findings related to anatomy, histology, physiology, neurology, neuroradiology, microsurgery, and endovascular surgery pertaining to the cerebellar flocculus or parafloccular spaces are summarized. A total of 298 perforating arteries were found in the dissected specimens, with a minimum of 15 to a maximum of 26 vessels per parafloccular perforating space. The average outer diameter of the cisternal portion of the perforating arteries was 0.11 ± 0.042 mm (mean ± SD) and the average length was 2.84 ± 1.2 mm. Detailed schematics and the surgical anatomy of the perforating vessels at the CPC and their clinical relevance are reported. The parafloccular space is a key entry point for many perforating vessels toward the middle cerebellar peduncle and lateral brainstem, and it must be respected and protected during surgical approaches to the

  18. PET and PVC Separation with Hyperspectral Imagery

    Science.gov (United States)

    Moroni, Monica; Mei, Alessandro; Leonardi, Alessandra; Lupo, Emanuela; La Marca, Floriana

    2015-01-01

    Traditional plants for plastic separation in homogeneous products employ material physical properties (for instance density). Due to the small intervals of variability of different polymer properties, the output quality may not be adequate. Sensing technologies based on hyperspectral imaging have been introduced in order to classify materials and to increase the quality of recycled products, which have to comply with specific standards determined by industrial applications. This paper presents the results of the characterization of two different plastic polymers—polyethylene terephthalate (PET) and polyvinyl chloride (PVC)—in different phases of their life cycle (primary raw materials, urban and urban-assimilated waste and secondary raw materials) to show the contribution of hyperspectral sensors in the field of material recycling. This is accomplished via near-infrared (900–1700 nm) reflectance spectra extracted from hyperspectral images acquired with a two-linear-spectrometer apparatus. Results have shown that a rapid and reliable identification of PET and PVC can be achieved by using a simple two near-infrared wavelength operator coupled to an analysis of reflectance spectra. This resulted in 100% classification accuracy. A sensor based on this identification method appears suitable and inexpensive to build and provides the necessary speed and performance required by the recycling industry. PMID:25609050

  19. PET and PVC separation with hyperspectral imagery.

    Science.gov (United States)

    Moroni, Monica; Mei, Alessandro; Leonardi, Alessandra; Lupo, Emanuela; Marca, Floriana La

    2015-01-20

    Traditional plants for plastic separation in homogeneous products employ material physical properties (for instance density). Due to the small intervals of variability of different polymer properties, the output quality may not be adequate. Sensing technologies based on hyperspectral imaging have been introduced in order to classify materials and to increase the quality of recycled products, which have to comply with specific standards determined by industrial applications. This paper presents the results of the characterization of two different plastic polymers--polyethylene terephthalate (PET) and polyvinyl chloride (PVC)--in different phases of their life cycle (primary raw materials, urban and urban-assimilated waste and secondary raw materials) to show the contribution of hyperspectral sensors in the field of material recycling. This is accomplished via near-infrared (900-1700 nm) reflectance spectra extracted from hyperspectral images acquired with a two-linear-spectrometer apparatus. Results have shown that a rapid and reliable identification of PET and PVC can be achieved by using a simple two near-infrared wavelength operator coupled to an analysis of reflectance spectra. This resulted in 100% classification accuracy. A sensor based on this identification method appears suitable and inexpensive to build and provides the necessary speed and performance required by the recycling industry.

  20. A Novel Perforator Flap Training Model Using a Chicken Leg.

    Science.gov (United States)

    Cifuentes, Ignacio J; Yañez, Ricardo A; Salisbury, Maria C; Rodriguez, José R; Varas, Julian E; Dagnino, Bruno L

    2016-04-01

    Living animal models are frequently used for perforator flap dissection training, but no ex vivo models have been described. The aim of this study is to present a novel nonliving model for perforator flap training based on a constant perforator in the chicken leg. A total of 15 chicken legs were used in this study. Anatomical dissection of the perforator was performed after its identification using ink injection, and in four of these specimens a perforator-based flap was raised. The anatomical dissection revealed a constant intramuscular perforator with a median length of 5.7 cm. Median proximal and distal vessel diameters were 0.93 and 0.4 mm, respectively. The median dissection time was 77.5 minutes. This study introduces a novel, affordable, and reproducible model for the intramuscular dissection of a perforator-based flap using an ex vivo animal model. Its consistent perforator and appropriate-sized vessels make it useful for training.

  1. Esophageal perforation

    Science.gov (United States)

    ... esophagus into the space around the lungs. Collapsed lung. X-rays taken after you drink a non-harmful dye can help pinpoint the location of the perforation. You may also have chest CT scan look for an abscess in the chest or esophageal cancer.

  2. [Iatrogen perforation of the rectum after colon radiography].

    Science.gov (United States)

    Eggum, R; Kressner, U; Haffner, J

    1998-05-10

    Perforation of the rectum following barium enema is relatively rare, occurring in 1 of 3,000 procedures. Colorectal perforation is a serious condition and early diagnosis is of paramount importance in order to avoid any delay in treating the patient. Direct suture of the perforation, lavage, presacral drainage and stomia are the preferred methods of primary surgical treatment.

  3. Discoloration of polyvinyl chloride (PVC) tape as a proxy for water-table depth in peatlands: validation and assessment of seasonal variability

    Science.gov (United States)

    Booth, Robert K.; Hotchkiss, Sara C.; Wilcox, Douglas A.

    2005-01-01

    Summary: 1. Discoloration of polyvinyl chloride (PVC) tape has been used in peatland ecological and hydrological studies as an inexpensive way to monitor changes in water-table depth and reducing conditions. 2. We investigated the relationship between depth of PVC tape discoloration and measured water-table depth at monthly time steps during the growing season within nine kettle peatlands of northern Wisconsin. Our specific objectives were to: (1) determine if PVC discoloration is an accurate method of inferring water-table depth in Sphagnum-dominated kettle peatlands of the region; (2) assess seasonal variability in the accuracy of the method; and (3) determine if systematic differences in accuracy occurred among microhabitats, PVC tape colour and peatlands. 3. Our results indicated that PVC tape discoloration can be used to describe gradients of water-table depth in kettle peatlands. However, accuracy differed among the peatlands studied, and was systematically biased in early spring and late summer/autumn. Regardless of the month when the tape was installed, the highest elevations of PVC tape discoloration showed the strongest correlation with midsummer (around July) water-table depth and average water-table depth during the growing season. 4. The PVC tape discoloration method should be used cautiously when precise estimates are needed of seasonal changes in the water-table.

  4. Study on plasma pre-functionalized PVC film grafted with TiO2/PVP to improve blood compatible and antibacterial properties

    International Nuclear Information System (INIS)

    Suganya, Arjunan; Shanmugavelayutham, Gurusamy; Rodríguez, Carmen Serra

    2017-01-01

    Research into the design of new biopolymers/polymer functionalized with nanoparticles is of tremendous interest to the medical sector, particularly with regard to blood-contacting devices. In this present study, a steady blood compatible and active antibacterial coating was fabricated by the grafting of titanium dioxide (TiO 2 )/polyvinylpyyrolidone (PVP) onto a polyvinyl chloride (PVC) film surface via the direct-current glow discharge plasma method. To enhance the chemical interaction between TiO 2 /PVP and PVC, the surfaces of the PVC films were functionalized by different plasmas (air, argon, and oxygen) before coating. In this study, the plasma parameters were varied, such as treatment time of about 5–20 min for a constant power of 100 W, potential 300 V, and a constant gas pressure of 2 Pa for air, argon, and oxygen gas environment. Then, the different plasma treatments on the PVC films, TiO 2 /PVP were grafted using a simple dip-coating method. In addition, the TiO 2 /PVP-grafted PVC films were characterized by contact angle, attenuated total reflectance Fourier transform infrared spectroscopy, field-emission scanning electron microscope, and x-ray photo electron spectroscopy. Importantly, TiO 2 /PVP is grafted onto the PVC surface due to the plasma-based retained functionality and demonstrates adhesive efficiency, which was observed by XPS. The bio-stability of the TiO 2 /PVP-modified PVC film was evaluated by in vitro platelet activation analysis and protein adsorption analysis. Then, the antibacterial properties were evaluated by the agar diffusion method against Escherichia coli . The result reveals that the grafting of TiO 2 /PVP was slightly higher for the 15 min oxygen plasma-functionalized PVC, which significantly decreases the platelet adhesion and protein adsorption. Moreover, the antibacterial properties of the 15 min oxygen plasma-functionalized PVC with TiO 2 /PVP-grafted film is also greatly improved compared with an air- and argon

  5. Pipe-to-pipe impact program

    International Nuclear Information System (INIS)

    Alzheimer, J.M.; Bampton, M.C.C.; Friley, J.R.; Simonen, F.A.

    1984-06-01

    This report documents the tests and analyses performed as part of the Pipe-to-Pipe Impact (PTPI) Program at the Pacific Northwest Laboratory. This work was performed to assist the NRC in making licensing decisions regarding pipe-to-pipe impact events following postulated breaks in high energy fluid system piping. The report scope encompasses work conducted from the program's start through the completion of the initial hot oil tests. The test equipment, procedures, and results are described, as are analytic studies of failure potential and data correlation. Because the PTPI Program is only partially completed, the total significance of the current test results cannot yet be accurately assessed. Therefore, although trends in the data are discussed, final conclusions and recommendations will be possible only after the completion of the program, which is scheduled to end in FY 1984

  6. Practical problems in radiation sterilization of medical devices made from plasticized PVC

    International Nuclear Information System (INIS)

    Beenen, J.H.

    1990-01-01

    The following three methods for sterilizing medical devices made from plasticised PVC are used in the Netherlands. 1. sterilization by steam, steam-air or superheated water. 2. sterilization by electron beam or gamma irradiation. 3. ethylene oxide sterilization. IV-bags, blood bags and other bag types for similar applications made from plasticized PVC are mostly sterilized by steam-air or super heated water, especially when filled or partly filled containers are considered. More complicated products or products with components that cannot resist steam sterilization of 121 0 C are sterilized by ethylene oxide or irradiation. These last two methods also are favoured for sterilizing empty bags where sticking of the surfaces at the sterilization temperature creates a serious handicap. Moreover, steam sterilization may cause a permanent opacity of some plastics. However, we have to add that due to developments in formulations steam sterilization of empty bags is going to be of an increasing importance. proven carcinogenity of the gas ethylene oxide, difficult deaeration and retention of the gas in plasticized PVC has increased the demand for better radiation resistant plastics as an alternative for steam sterilization. (author)

  7. A Laboratory Experimental Study: An FBG-PVC Tube Integrated Device for Monitoring the Slip Surface of Landslides

    Science.gov (United States)

    Zhang, Shaojie; Chen, Jiang; Teng, Pengxiao; Wei, Fangqiang; Chen, Qiao

    2017-01-01

    A new detection device was designed by integrating fiber Bragg grating (FBG) and polyvinyl chloride (PVC) tube in order to monitor the slip surface of a landslide. Using this new FBG-based device, a corresponding slope model with a pre-set slip surface was designed, and seven tests with different soil properties were carried out in laboratory conditions. The FBG sensing fibers were fixed on the PVC tube to measure strain distributions of PVC tube at different elevation. Test results indicated that the PVC tube could keep deformation compatible with soil mass. The new device was able to monitor slip surface location before sliding occurrence, and the location of monitored slip surface was about 1–2 cm above the pre-set slip surface, which basically agreed with presupposition results. The monitoring results are expected to be used to pre-estimate landslide volume and provide a beneficial option for evaluating the potential impact of landslides on shipping safety in the Three Gorges area. PMID:29084157

  8. Perforated duodenal ulcer: an unusual complication of gastroenteritis.

    OpenAIRE

    Wilson, J M; Darby, C R

    1990-01-01

    A 7 year old boy was admitted to hospital with gastroenteritis, which was complicated by an acute perforated duodenal ulcer. After oversewing of the perforation he made an uncomplicated recovery. Peptic ulceration is under-diagnosed in childhood and this leads to delay in diagnosis and appropriate management. Ulceration is associated with severe illness and viral infections, but perforation is rare.

  9. Iatrogen perforation of the rectum following barium enema

    International Nuclear Information System (INIS)

    Eggum, R.; Kressner, U.; Haffner, J.

    1998-01-01

    Perforation of the rectum following barium enema is relatively rare, occurring in 1 of 3,000 procedures. Colorectal perforation is a serious condition and early diagnosis is of paramount importance in order to avoid any delay in treating the patient. Direct suture of the perforation, lavage, presacral drainage and stomia are the preferred methods of primary surgical treatment. 10 refs., 1 fig

  10. Casing of preinsulated district heating pipes. Functional Requirements. Scientific report

    Energy Technology Data Exchange (ETDEWEB)

    Bryder, K.L.; Feld, T.; Randloev, P.; Vestergaard, J.B.; Noergaard Pedersen, H.; Palle, S.; Amby, L.

    1996-10-01

    Requirements for the wall thickness of the casing pipes in Europe were formulated to clarify the laying conditions, representative for the European district heating areas. We achieved a broad estimate by defining four scenarios for the laying of district heating pipes. It is common to the four scenarios that that all bends, branches etc. are always laid in sand. The four scenarios are differentiated by soil types. The soil types include: Uniform sand, Well graded gravel, Sand with fines and Sand with crushed stone. In the following analysis it was possible to examine the influence from following parameters: Casing thickness; Diameter of steel pipe; Diameter of casing; Material properties (PUR and PE); Soil type. The results from the model showed that uniform sand is the absolute best soil type. Based on the results from and earlier project a laboratory method has been developed. The result was a test method based on the indentation of three mandrels with a diameter of {phi}30 mm with a taper with an angle of 45 deg. and with roundings on the apex of R5 mm, R10 mm and R15 mm, respectively. The mandrels simulate stones. The examinations among other things showed that even a 1.5 mm casing demands an indentation of 20 mm with a R5 mm mandrel before it is perforated. The demanded force is 1.6 kN, which is considerably higher than the theoretically highest force in an actual situation. On this background it is recommended that the minimum requirement for the wall thickness of the casings with diameters less than 200 mm should still follow the EN 253, whereas the minimum requirement for the larger casing pipes securely can be reduced. Based on the tests and an evaluation of the safety factors it is proposed that the wall thickness for the largest pipes can be reduced 50%. Thus the wall thickness of an 800 mm casing should be 6.6 mm with a linear reduction down to 3 mm for 180 mm casing. (EG)

  11. Photoetching of Immobilized TiO2-ENR50-PVC Composite for Improved Photocatalytic Activity

    Directory of Open Access Journals (Sweden)

    M. A. Nawi

    2012-01-01

    Full Text Available Commercially acquired TiO2 photocatalyst (99% anatase powder was mixed with epoxidized natural rubber-50 (ENR50/polyvinyl chloride (PVC blend by ultrasonication and immobilized onto glass plates as TiO2-ENR50-PVC composite via a dip-coating method. Photoetching of the immobilized TiO2-ENR50-PVC composite was investigated under the irradiation of a 45 W compact fluorescent lamp and characterized by chemical oxygen demand (COD analysis, scanning electron microscopy-energy dispersive X-ray (SEM-EDX spectrometry, thermogravimetry analysis (TGA, and fourier transform infrared (FTIR spectroscopy. The BET surface area of the photoetched TiO2 composite was observed to be larger than the original TiO2 powder due to the systematic removal of ENR50 while PVC was retained within the composite. It also exhibited better photocatalytic efficiency than the TiO2 powder in a slurry mode and was highly reproducible and reusable. More than 98% of MB removal was consistently achieved for 10 repeated runs of the photo-etched photocatalyst system. About 93% of the 20 mg L−1 MB was mineralized over a period of 480 min. The presence of SO42−, NO3−, and Cl− anions was detected in the mineralized solution where the solution pH was reduced from 7 to 4.

  12. Parasacral Perforator Flaps for Reconstruction of Sacral Pressure Sores.

    Science.gov (United States)

    Lin, Chin-Ta; Chen, Shih-Yi; Chen, Shyi-Gen; Tzeng, Yuan-Sheng; Chang, Shun-Cheng

    2015-07-01

    Despite advances in reconstruction techniques, pressure sores continue to present a challenge to the plastic surgeon. The parasacral perforator flap is a reliable flap that preserves the entire contralateral side as a future donor site. On the ipsilateral side, the gluteal muscle itself is preserved and all flaps based on the inferior gluteal artery are still possible. We present our experience of using parasacral perforator flaps in reconstructing sacral defects. Between August 2004 and January 2013, 19 patients with sacral defects were included in this study. All the patients had undergone surgical reconstruction of sacral defects with a parasacral perforator flap. The patients' sex, age, cause of sacral defect, flap size, flap type, numbers of perforators used, rotation angle, postoperative complications, and hospital stay were recorded. There were 19 parasacral perforator flaps in this series. All flaps survived uneventfully except for 1 parasacral perforator flap, which failed because of methicillin-resistant Staphylococcus aureus infection. The overall flap survival rate was 95% (18/19). The mean follow-up period was 17.3 months (range, 2-24 months). The average length of hospital stay was 20.7 days (range, 9-48 days). No flap surgery-related mortality was found. Also, there was no recurrence of sacral pressure sores or infected pilonidal cysts during the follow-up period. Perforator-based flaps have become popular in modern reconstructive surgery because of low donor-site morbidity and good preservation of muscle. Parasacral perforator flaps are durable and reliable in reconstructing sacral defects. We recommend the parasacral perforator flap as a good choice for reconstructing sacral defects.

  13. Acquired perforating dermatosis in a patient with chronic renal failure.

    Science.gov (United States)

    Fernandes, Karen de Almeida Pinto; Lima, Lourenço de Azevedo; Guedes, Juliana Chaves Ruiz; Lima, Ricardo Barbosa; D'Acri, Antônio Macedo; Martins, Carlos José

    2016-01-01

    Perforating dermatoses are a group of skin diseases characterized by transepidermal elimination of dermal material. The disease is divided into two groups: the primary group and the secondary group. The classical or primary perforating dermatoses are subdivided into four types according to the eliminated dermal materials: Kyrle disease, perforating reactive collagenosis, elastosis perforans serpiginosa, and perforating folliculitis. The secondary form is known as acquired perforating dermatosis. The term was proposed in 1989 by Rapini to designate the perforating dermatoses affecting adult patients with systemic disease, regardless of the dermal materials eliminated. This report describes a case of the disease with elimination of collagen and elastic fibers in a patient with chronic renal failure.

  14. Use of pulsed neutron logging to evaluate perforation washing

    International Nuclear Information System (INIS)

    Dimon, C.A.

    1986-01-01

    This invention relates to the use of pulsed neutron logging techniques before and after perforation washing operations are performed to evaluate the degree of success of the perforation washing operations. Well logging operations of a type designed to respond to the difference between a formation immediately behind the well sheath and voids in the formation are performed both before and after the perforation washing operation. differences between the two resulting logs are then indicative of voids created by perforation washing. In a preferred embodiment, pulsed neutron logging is used as the logging technique, while a weighted brine having a high absorption cross section to pulsed neutrons is used as the perforation washing fluid

  15. Idiopathic gastric perforation in an asplenic infant | Olsen | African ...

    African Journals Online (AJOL)

    Introduction: The cause of idiopathic gastric perforations in neonates remains unknown. Perforations of the abdominal oesophagus, stomach and duodenum in infants and children are the rarest type of intestinal perforations. There are 21 reported cases of an idiopathic gastric rupture in nonneonates. Case Report: A ...

  16. MECHANICAL, ELECTRICAL, AND THERMAL PROPERTIES OF MALEIC ANHYDRIDE MODIFIED RICE HUSK FILLED PVC COMPOSITES

    OpenAIRE

    Navin Chand; Bhajan Das Jhod

    2008-01-01

    Unmodified and modified rice husk powder filled PVC composites were prepared having different amounts of rice husk powder. Mechanical, thermal, and electrical properties of these composites were determined. The tensile strength of rice husk powder PVC composites having 0, 10, 20, 30, and 40 weight percent of rice husk powder was found to be 33.9, 19.4, 18.1, 14.6, and 9.5 MPa, respectively. Adding of maleic anhydride- modified rice husk powder improved the tensile strength of rice husk powder...

  17. CORRELATION BETWEEN TYMPANIC MEMBRANE PERFORATION AND HEARING LOSS

    Directory of Open Access Journals (Sweden)

    Lidija RISTOVSKA

    2016-04-01

    Full Text Available Introduction: Perforation of the tympanic membrane primarily results from middle ear infections, trauma or iatrogenic causes. The perforation causes conductive hearing loss by reducing the surface area available for sound transmission to the ossicular chain. Objective: The objective was to analyze the characteristics of tympanic membrane perforations in relation to hearing loss and to determine the type and degree of hearing loss. Materials and methods: We analyzed audiometric, otoscopic findings and medical reports of 218 patients, 114 males (52.3% and 104 females (47.7%, aged 9 to 75 years (mean age of 47.9 years, examined during the period of November 2012 to October 2015. For statistical data analysis we used Chi-square test with level of significance p<0.05. Results: Most of the patients had unilateral perforations (89% with right ear predominance and involvement of two quadrants of pars tensa (37.2%. Mean air-bone gap was 23.9 dB. The largest air-bone gap was at frequency of 250 Hz. Most of the patients (73.1% had mixed hearing loss (p=0.032, and average hearing thresholds from 21 to 40 dB. Conclusion: Mean air-bone gap is largest at the lower frequencies, and decreases as frequency increases. Size of the perforation has effect on hearing loss. Mean air-bone gap increases with increasing size of the perforation. There is no big difference between the mean air-bone gap in posterior versus anterior perforations.

  18. Stabilizing effect of epoxidized sunflower oil as a secondary stabilizer for Ca/Hg stabilized PVC

    Directory of Open Access Journals (Sweden)

    2008-01-01

    Full Text Available Unsaturated triglyceride oil sunflower was epoxidized and characterized by chemical and spectroscopic methods. Epoxidized sunflower oil (ESO was used as an organic thermal co-stabilizer for rigid poly(vinyl chloride (PVC in the presence of tricalcium dicitrate (Ca3(C6H5O72 and mercury (II acetate (Hg(CH3COO2. The thermo-oxidative degradation of PVC was studied in the presence of these ternary stabilizer systems at 170, 180, 190 and 200°C in N2 atmosphere. The effects of metal carboxylate combination Ca/Hg in the absence and in the presence of epoxidized sunflower oil on static heat treatment of PVC have been studied. The formation of polyene sequences was investigated by UV-visible and FT-IR spectroscopy and by comparing viscosity data obtained in the presence and in the absence of the additives. It was found that the additives retard the rate of degradation and reduce the extent of polymer chain scission associated with the thermal degradation of poly(vinyl chloride. Synergistic effects were found when stabilizer was blended in 50:50 weight ratios with either. It was found that ESO exerted a stabilizing effect on the degradation of PVC. The activation energy for degraded PVC in absence of stabilizers was 38.6 kJ•mol–1 and in the presence of Ca/Hg and Ca/Hg/ESO were 53.3 and 64.7 kJ•mol–1 respectively. In order of compare the efficiency of the epoxidized sunflower oil with these metal soap stabilizers, thermal stabilities were evaluated on the basis of evolved hydrogen chloride determined by conductometry technique and degree of discoloration are discussed.

  19. Gallbladder perforation complicating typhoid fever: report of two cases.

    Science.gov (United States)

    Gali, B M; Ali, N; Agbese, G O; Duna, V D; Dawha, S D; Ismai, G I; Mohammed, M

    2011-01-01

    Gallbladder perforation (GBP) is rare and as a complication of typhoid fever is extremely rare. We present two consecutive patients with GBP diagnosed incidentally at laparotomy. Information on the management of two patients with gallbladder perforation seen at Federal Medical Centre Azare in June and October 2008 was extracted from their case records. The two patients were both males aged 13 years and 16 years. They both presented with high fever of more than 2 weeks duration; and abdominal pain and distension. Both patients had features of generalised peritonitis. Pre-operative diagnoses of typhoid enteric perforation were made based on a positive Widal test. Intra-operative findings however, were that of bile peritonitis and gallbladder perforation. Both had cholecystectomy. Culture of the bile aspirate yielded Salmonella typhi. Gallbladder perforation secondary to typhoid fever should be considered as a differential diagnosis in patients with suspected typhoid enteric perforation in typhoid fever endemic region.

  20. Hyperbilirubinemia as a predictor for appendiceal perforation

    DEFF Research Database (Denmark)

    Burcharth, J; Pommergaard, H C; Rosenberg, J

    2013-01-01

    Delayed or wrong diagnosis in patients with appendicitis can result in perforation and consequently increased morbidity and mortality. Serum bilirubin may be a useful marker for appendiceal perforation. The purpose of this systematic review was to evaluate studies investigating elevated serum...

  1. Properties of Commercial PVC Films with Respect to Electron Dosimetry

    DEFF Research Database (Denmark)

    Miller, Arne; Liqing, Xie

    The properties of three commercially available polyvinyl chloride (PVC) film supplies and one made without additives were tested with respect to their application as routine dose monitors at electron accelerators. Dose fractionation was found to increase the response and the post-irradiation heat...

  2. Sigmoid Colonic Perforation with Faecal Peritonitis due to Faecaloma

    Directory of Open Access Journals (Sweden)

    Ibrahim Khalil

    2014-09-01

    Full Text Available Colon perforation is an uncommon event usually caused by malignancy, diverticular disease, amoebic colitis, steroid therapy, trauma and ulcerative colitis, but stercoral perforation is very rare. Severe chronic constipation is considered to be the main causative factor in development of stercoral perforation of colon. Sometimes it can also produce catastrophic complications like colonic obstruction, faecal peritonitis and septicaemia. We report a rare case of sigmoid colonic perforation with faecal peritonitis and pneumoperitonium due to faecaloma which was diagnosed after exploratory laparotomy.

  3. Peptic ulcer perforation

    African Journals Online (AJOL)

    FinePrint

    2015-06-01

    Jun 1, 2015 ... Peptic ulcer perforation is one of the surgical complications of peptic ulcer ... Treatment can be operative or non-operative followed by proton .... chronic gastritis without evidence of ... inhibits pancreatic bicarbonate secretion.

  4. Pipe whip: a summary of the damage observed in BNL pipe-on-pipe impact tests

    International Nuclear Information System (INIS)

    Baum, M.R.

    1987-01-01

    This paper describes examples of the damage resulting from the impact of a whipping pipe on a nearby pressurised pipe. The work is a by-product of a study of the motion of a whipping pipe. The tests were conducted with small-diameter pipes mounted in rigid supports and hence the results are not directly applicable to large-scale plant applications where flexible support mountings are employed. The results illustrate the influence of whipping pipe energy, impact position and support type on the damage sustained by the target pipe. (author)

  5. Blendas PVC/NBR por processamento reativo I: desenvolvimento do processo de vulcanização Dinâmica in situ PVC/NBR blends by reactive processing I: in situ dynamic vulcanization process

    Directory of Open Access Journals (Sweden)

    Fábio R. Passador

    2007-06-01

    Full Text Available Vulcanização dinâmica é o processo de vulcanização de um elastômero durante a mistura no estado fundido com um termoplástico, que resulta em uma classe de materiais denominada termoplásticos vulcanizados. Neste trabalho, um novo tipo de termoplástico vulcanizado foi obtido por vulcanização dinâmica in situ da blenda PVC/NBR, utilizando-se um sistema de cura a base de enxofre (S e combinação dos aceleradores 2,2-ditiomercaptobenzotiazol (MBTS e dissulfeto de tetrametiltiuram (TMTD. As blendas PVC/NBR (90/10, 80/20 e 70/30% em massa foram processadas em um reômetro de torque Haake (Rheomix 600 a 160 °C com rotação de 60 rpm. As blendas obtidas por processamento reativo foram caracterizadas por calorimetria diferencial de varredura (DSC para determinação do grau de cura. Observou-se aumento no grau de cura das blendas com o tempo de mistura sendo o sistema de cura considerado eficiente.Dynamic vulcanization is a process of vulcanization of an elastomer during melt mixing with a thermoplastic wich results in material called thermoplastic vulcanizates or TPVs. In this study, a new kind of TPV was obtained by in situ dynamic curing of poly(vinyl chloride (PVC/nitrile rubber (NBR blends. The crosslinking of PVC/NBR blends was accomplished using sulphur (S/tetramethylthiuram disulphide (TMTD and mercaptobenzthiazyl disulphide (MBTS curative system during the reactive processing. The blends of PVC/NBR at the ratio of 90/10; 80/20 and 70/30 wt. (% were melt mixed using a Haake Rheomix 600 at 160 °C and rotor speed of 60 rpm. The curing behavior of NBR was investigated by a Monsanto Rheometer and the degree of cure was calculated using differential scanning calorimetry (DSC for different mixing times. It was observed that the degree of cure increases with the mixing time and the crosslinking system used in this work was considered efficient.

  6. Perforated peptic ulcer following gastric bypass for obesity.

    Science.gov (United States)

    Macgregor, A M; Pickens, N E; Thoburn, E K

    1999-03-01

    Peptic ulcer in the excluded segment of a gastric bypass performed in the management of morbid obesity has only rarely been reported in the literature. The purpose of this study is to review our experience with the condition in a series of 4300 patients who underwent gastric-restrictive surgery between 1978 and 1997. Eleven patients presented with acute perforation of a peptic ulcer in the excluded gastric segment. Nine ulcers were duodenal, one was gastric, and one patient had both gastric and duodenal perforations. The time between primary gastric-restrictive surgery and ulcer perforation varied from 20 days to 12 years. All patients presented with upper abdominal pain. The classical radiological sign of perforated peptic ulcer, free air under the diaphragm, did not occur in any patient. Nine patients were initially treated by primary closure of the perforation with subsequent definitive ulcer therapy by vagotomy, pyloroplasty, or gastrectomy. One case, initially treated elsewhere, was managed by placement of a Malecot catheter through the duodenal perforation, gastrostomy, and peritoneal drainage. One recent case remains symptom-free on H2 blockers after simple closure. There was no mortality. Six cases were previously reported in the literature with a 33 per cent mortality rate.

  7. Functionalization of PVC membrane with ss oligonucleotides for a potentiometric biosensor.

    Science.gov (United States)

    Shishkanova, T V; Volf, R; Krondak, M; Král, V

    2007-05-15

    A novel application of a single stranded (ss) oligonucleotide as an active component of polymeric membrane in an ion-selective electrode (ISE) is described. The original oligonucleotides, oligo(dA)(15), modified by cholesterol, triphenylmethyl and hexadecyl derivatives, were immobilized into poly(vinyl chloride) (PVC) membrane using extraction protocol. In parallel, the adsorption protocol was used to immobilize unmodified oligo(dA)(15) on the PVC membrane based on tridodecylmethyammonium chloride (TDDMA(+)Cl(-)). Immobilization of ss oligonucleotide probe through spacer was more effective for the potentiometric detection of the hybridization between complementary oligonucleotides. It was found that cholesterol-oligo(dA)(15) modified membranes were sensitive toward complementary oligo(dT)(15) in the concentration range 2-80 nM at pH 7. An explanation for the detection mechanism is proposed.

  8. Composite phase change materials prepared by encapsuling paraffin in PVC macrocapsules

    International Nuclear Information System (INIS)

    Chen, Yingbo; Zhang, Shifeng; Zhang, Qi; Chen, Yusheng; Zhang, Yufeng

    2014-01-01

    Highlights: • PVC macrocapsules coated with SiO 2 were synthesized. • Paraffin was encapsuled in the capsules. • The composite PCM has high heat capacity. • The composite PCM has no surpercooling. - Abstract: A novel phase change material capsules with SiO 2 in their surface was prepared by absorbing paraffin into PVC hollow capsules and by the polycondensation reaction of TEOS in different conditions. X-ray photoelectron spectroscopy (XPS) analysis and scanning electronic microscope (SEM) were used to determine chemical composition and microstructure of the composite capsules, respectively. Enthalpy capacity and thermal stability of the composite capsules are systematically characterized by using differential scanning calorimeter (DSC), thermogravimetric analyzer (TGA) and thermocycling tests. The composite has high heat capacity with good stability and absence of supercooling phenomena

  9. Stercoral perforation in a 17-year old.

    LENUS (Irish Health Repository)

    McHugh, S

    2012-02-01

    INTRODUCTION: Stercoral perforation is a rare cause of perforation. This is the first reported case where a partial eating disorder (ED) is the primary causative differential. CASE PRESENTATION: We present the case of a 17-year-old girl who presented to her local Emergency Department with a 24-h history of left-sided abdominal pain. She subsequently deteriorated and a computed tomography scan of her abdomen showed gross distension of the large bowel with a sigmoid perforation. She underwent total colectomy with end ileostomy. Histology reported stercoral perforation but normal bowel ganglia. While an inpatient she was reviewed by the Psychiatric team who were concerned she was suffering from a partial ED. CONCLUSION: This case highlights the importance of a multidisciplinary approach in optimally treating patients such as these. Aggressive medical management with involvement of a psychiatric team and dietetics addresses any underlying causative psychiatric issues and helps prevent recurrence.

  10. Stercoral perforation in a 17-year old.

    LENUS (Irish Health Repository)

    McHugh, S

    2009-04-02

    INTRODUCTION: Stercoral perforation is a rare cause of perforation. This is the first reported case where a partial eating disorder (ED) is the primary causative differential. CASE PRESENTATION: We present the case of a 17-year-old girl who presented to her local Emergency Department with a 24-h history of left-sided abdominal pain. She subsequently deteriorated and a computed tomography scan of her abdomen showed gross distension of the large bowel with a sigmoid perforation. She underwent total colectomy with end ileostomy. Histology reported stercoral perforation but normal bowel ganglia. While an inpatient she was reviewed by the Psychiatric team who were concerned she was suffering from a partial ED. CONCLUSION: This case highlights the importance of a multidisciplinary approach in optimally treating patients such as these. Aggressive medical management with involvement of a psychiatric team and dietetics addresses any underlying causative psychiatric issues and helps prevent recurrence.

  11. Colonic carcinoma with multiple small bowel perforations mimicking intestinal obstruction

    Directory of Open Access Journals (Sweden)

    Khanna Rahul

    2006-09-01

    Full Text Available Abstract Background Carcinoma of the colon may present with perforation proximal to the site of malignancy. Caecum is the commonest site of perforation if the ileocecal valve is patent and the jejunal and ileal perforations are very rare. Case presentation A 35 year male presented with intestinal obstruction. Emergency laparotomy revealed carcinoma of the transverse colon with multiple pinpoint perforations along antimesenteric border of ileum, which were wrapped with omentum, and no peritoneal contamination was present. Extended right hemicolectomy with jejunocolic anastomosis was done. Patient made uneventful recovery in postoperative period and was treated with adjuvant chemotherapy. Conclusion Patients with colonic carcinoma and incompetent ileocecal valve may present with intestinal perforation. Increased intraluminal pressure and closed loop obstruction may lead to ischemia and perforation of the small bowel.

  12. Energy Analysis of Solar Collector With perforated Absorber Plate

    Directory of Open Access Journals (Sweden)

    Ammar A. Farhan

    2017-09-01

    Full Text Available The thermal performance of three solar collectors with 3, 6 mm and without perforation absorber plate was assessed experimentally. The experimental tests were implemented in Baghdad during the January and February 2017. Five values of airflow rates range between 0.01 – 0.1 m3/s were used through the test with a constant airflow rate during the test day. The variation of the following parameters air temperature difference, useful energy, absorber plate temperature, and collector efficiency was recorded every 15 minutes. The experimental data reports that the increases the number of absorber plate perforations with a small diameter is more efficient rather than increasing the hole diameter of the absorber plate with decreasing the perforation numbers. Maximum air temperature difference throughout the solar collector with 3, 6 mm perforations and without perforations are 17, 15, and 12 oC, respectively. Also, it can be concluded that the energy gained from the solar collector with 3 mm perforation absorber plate is 28.2 % more than the energy gained from solar collector without holes per day for 0.1 m3/s airflow rate. The maximum values of the thermal performance curves are 0.67, 0.64, and 0.56 for the solar collector with 3, 6 mm, and without perforations, respectively.

  13. Arrangement for formation perforating and fracturing

    Energy Technology Data Exchange (ETDEWEB)

    Belyaev, B M; Vitsenii, E M; Zheltov, Yu P; Nikolaev, S I

    1962-03-06

    An arrangement for perforating and hydraulic fracturing, to be lowered on a wire line, consists of a chamber with a shaped charge, a head and a nozzle. This arrangement enables carrying out, simultaneously, the operations of perforating and fracturing. The device may be equipped with separate sections with shaped charges and a powder chamber in which powder charges are placed, designed to be ignited in sequence by slow- acting electric igniters. For controlling the gas pressure and strengthening the arrangement in the zone of perforation, the device is equipped with rubber seals which release the ring elements under pressure of explosive gas. Between the walls of the casing and the rubber seals is an annular space through the gas escapes.

  14. Satisfactory reliability among nursing students using the instrument PVC ASSESS to evaluate management of peripheral venous catheters.

    Science.gov (United States)

    Ahlqvist, Margary; Berglund, Britta; Nordström, Gun; Klang, Birgitta; Johansson, Eva

    2014-01-01

    Nursing students should be given opportunities to participate in clinical audits during their education. However, audit tools are seldom tested for reliability among nursing students. The aim of this study was to present reliability among nursing students using the instrument PVC assess to assess management of peripheral venous catheters (PVCs) and PVC-related signs of thrombophlebitis. PVC assess was used to assess 67 inserted PVCs in 60 patients at ten wards at a university hospital. One group of nursing students (n=4) assessed PVCs at the bedside (inter-rater reliability) and photographs of these PVCs were taken. Another group of students (n=3) assessed the PVCs in the photographs after 4 weeks (test-retest reliability). To determine reliability, proportion of agreement [P(A)] and Cohen's kappa coefficient (κ) were calculated. For bedside assessment of PVCs, P(A) ranged from good to excellent (0.80-1.0) in 55% of the 26 PVC assess items that were tested. P(A) was poor (satisfactory reliability among nursing students. However, students need training in how to use the instrument before assessing PVCs.

  15. Pipe support

    International Nuclear Information System (INIS)

    Pollono, L.P.

    1979-01-01

    A pipe support for high temperature, thin-walled piping runs such as those used in nuclear systems is described. A section of the pipe to be suppported is encircled by a tubular inner member comprised of two walls with an annular space therebetween. Compacted load-bearing thermal insulation is encapsulated within the annular space, and the inner member is clamped to the pipe by a constant clamping force split-ring clamp. The clamp may be connected to pipe hangers which provide desired support for the pipe

  16. Selective separation of virgin and post-consumer polymers (PET and PVC) by flotation method

    International Nuclear Information System (INIS)

    Burat, Firat; Gueney, Ali; Olgac Kangal, M.

    2009-01-01

    More and more polymer wastes are generated by industry and householders today. Recycling is an important process to reduce the amount of waste resulting from human activities. Currently, recycling technologies use relatively homogeneous polymers because hand-sorting waste is costly. Many promising technologies are being investigated for separating mixed thermoplastics, but they are still uneconomical and unreliable. At present, most waste polymers cause serious environmental problems. Burning polymers for recycling is not practiced since poisonous gases are released during the burning process. Particularly, polyvinyl chloride (PVC) materials among waste polymers generate hazardous HCl gas, dioxins containing Cl, etc., which lead to air pollution and shorten the life of the incinerator. In addition, they make other polymers difficult to recycle. Both polyethylene terephthalate (PET) and PVC have densities of 1.30-1.35 g/cm 3 and cannot be separated using conventional gravity separation techniques. For this reason, polymer recycling needs new techniques. Among these techniques, froth flotation, which is also used in mineral processing, can be useful because of its low cost and simplicity. The main objective of this research is to recycle PET and PVC selectively from post-consumer polymer wastes and virgin polymers by using froth flotation. According to the results, all PVC particles were floated with 98.8% efficiency in virgin polymer separation while PET particles were obtained with 99.7% purity and 57.0% efficiency in post-consumer polymer separation.

  17. PVC--as flooring material--and its association with incident asthma in a Swedish child cohort study.

    Science.gov (United States)

    Larsson, M; Hägerhed-Engman, L; Kolarik, B; James, P; Lundin, F; Janson, S; Sundell, J; Bornehag, C G

    2010-12-01

    The Dampness in Buildings and Health study (DBH) started in the year 2000 in Värmland, Sweden, with a baseline questionnaire sent to all children (n = 14,077) aged 1-6. Five years later, a follow-up questionnaire was sent to the children who were 1-3 years at baseline. A total of 4779 children participated in both the baseline and the follow-up studies and constitute the study population in this cohort study. The aim of this study was to examine the association between exposure to PVC-flooring in the child's and parent's bedroom in homes of children aged 1-3 and the incidence of asthma, rhinitis, and eczema during the following 5-year period. Adjusted analyses showed that the incidence of asthma among children was associated with PVC-flooring in the child's bedroom (AOR 1.52; 95% CI 0.99-2.35) and in the parent's bedroom (1.46; 0.96-2.23). The found risks were on borderline of significance and should therefore be interpreted with caution. There was further a positive relationship between the number of rooms with PVC-flooring and the cumulative incidence of asthma. PVC-flooring was found to be a stronger risk factor for incident asthma in multifamily homes when compared with single-family houses and in smoking families compared with non-smoking families and in women. These longitudinal data from the DBH study found an association between the presence of PVC-flooring in the home and incident asthma in children. However, earlier results from the DBH study have shown that PVC-flooring is one important source for phthalates in indoor dust, and exposure to such phthalates was found to be associated with asthma and allergy among children. This emphasizes the need for prospective studies that focus on the importance of prenatal and neonatal exposure to phthalates in the development of asthma and allergy in children. © 2010 John Wiley & Sons A/S.

  18. Intraabdominal contamination after gallbladder perforation during laparoscopic cholecystectomy and its complications.

    Science.gov (United States)

    Kimura, T; Goto, H; Takeuchi, Y; Yoshida, M; Kobayashi, T; Sakuramachi, S; Harada, Y

    1996-09-01

    Gallbladder perforation often occurs during laparoscopic cholecystectomy. The frequency and causes of gallbladder perforation as well as the relevant clinical background factors were investigated in 110 patients undergoing laparoscopic cholecystectomy. We also evaluated intraperitoneal contamination by bacteria and gallstones at the time of gallbladder perforation and investigated whether perforation caused early or late postoperative complications. Intraoperative gallbladder perforation occurred in 29 of the 110 patients (26.3%). It was caused by injury with an electric knife during dissection of the gallbladder bed, injury during gallbladder retraction with grasping forceps, injury during gallbladder extraction from the abdomen, and slippage of cystic duct clips (potentially causing bile and stone spillage). Perforation was more frequent in patients with positive bile cultures and in those with pigment stones (p gallbladder perforation is sometimes unavoidable during laparoscopic cholecystectomy, the risk of severe complications appears to be minimized by early closure of perforation, retrieval of as many of the spilled stones as possible, and intraperitoneal lavage.

  19. The influence of soil and landfill leachate microorganisms in the degradation of PVC/PCL films cast from DMF

    Directory of Open Access Journals (Sweden)

    Adriana de Campos

    2012-01-01

    Full Text Available While the use of plastics continues to increase in our daily lives in a growing range products, these materials are very persistent in the environment. The blending of aliphatic polyesters with other thermoplastic polymers is a profitable way of producing materials with changed physical properties and biodegradability, which can facilitate microbial adhesion to the polymer matrix and help to reduce (post-consumer degradation time of these materials in landfills. This study was an investigation of the biodegradation of films of blends of poly(vinyl chloride (PVC and poly(ε-caprolactone (PCL by soil microorganisms and leachate, by means of respirometry, infrared absorption spectroscopy (FTIR, differential calorimetry scanning (DSC, scanning electron microscopy (SEM, contact angle and weight loss. The results showed that in the soil, the films suffered oxidative biodegradation. The PCL promoted degradation of the PVC in the film of PVC/PCL and the PVC inhibited the rapid degradation of the PCL.

  20. Casing of preinsulated district heating pipes. Functional Requirements. Enclosures

    Energy Technology Data Exchange (ETDEWEB)

    Bryder, K.L.; Feld, T.; Randloev, P.; Vestergaard, J.B.; Noergaard Pedersen, H.; Palle, S.; Amby, L.

    1996-10-01

    Requirements for the wall thickness of the casing pipes in Europe were formulated. In order to clarify the laying conditions, representative for the European district heating areas. It was possible to achieve a sufficiently broad estimate by defining four scenarios for the laying of district heating pipes. It is common to the four scenarios that that all bends, branches etc. are always laid in sand. The four scenarios are differentiated by soil types. The soil types include: Uniform sand, Well graded gravel, Sand with fines and Sand with crushed stone. In the following analysis it was possible to examine the influence from following parameters: Casing thickness; Diameter of steel pipe; Diameter of casing; Material properties (PUR and PE); Soil type. The results from the model showed that uniform sand is the absolute best soil type. Based on the results from and earlier project a laboratory method has been developed. The result was a test method based on the indentation of three mandrels with a diameter of {phi}30 mm with a taper with an angle of 45 deg. and with roundings on the apex of R5 mm, R10 mm and R15 mm, respectively. The mandrels simulate stones. The examinations among other things showed that even a 1.5 mm casing demands an indentation of 20 mm with a R5 mm mandrel before it is perforated. The demanded force is 1.6 kN, which is considerably higher than the theoretically highest force in an actual situation. On this background it is recommended that the minimum requirement for the wall thickness of the casings with diameters less than 200 mm should still follow the EN 253, whereas the minimum requirement for the larger casing pipes securely can be reduced. Based on the tests and an evaluation of the safety factors it is proposed that the wall thickness for the largest pipes can be reduced 50%. Thus the wall thickness of an 800 mm casing should be 6.6 mm with a linear reduction down to 3 mm for 180 mm casing. (EG)

  1. MRI of perforated gall bladder

    International Nuclear Information System (INIS)

    Sood, B.; Jain, M.; Khandelwal, N.; Singh, P.; Suri, S.

    2002-01-01

    Gall bladder perforation is a dreaded complication of acute cholecystitis that, if not diagnosed early in the course, might have a poor prognosis. Both CT and ultrasonography have been used until now extensively for the diagnosis of acute cholecystitis, but diagnosis of perforation is always difficult. Magnetic resonance, by its superior soft tissue resolution and multiplanar capability, is a better modality and should fare better than ultrasonography and CT, as demonstrated in our case. Magnetic resonance imaging demonstrates the wall of the gall bladder and defects to a much better advantage and more convincingly. In addition, MR colangiopancreatography images demonstrate the biliary tree better than other modalities. We suggest that in the case of acute cholecystitis, if perforation is suspected and CT and ultrasonography are not conclusive, MR should be the modality of choice. It can be used as a first line of investigation; however, it might not be cost-effective. Copyright (2002) Blackwell Science Pty Ltd

  2. Electrical and spectroscopic characterization of polyaniline-polyvinyl chloride (PANI-PVC) blends doped with sodium thiosulphate

    International Nuclear Information System (INIS)

    Ameen, Sadia; Ali, Vazid; Zulfequar, M.; Mazharul Haq, M.; Husain, M.

    2008-01-01

    Polyaniline is doped with sodium thiosulphate in aqueous tetrahydrofuran (THF) and the blended films have been prepared by changing the amount of doped polyaniline (PANI) in the fixed amount of polyvinyl chloride (PVC). The electrical conductivity of various samples of polyaniline-polyvinyl chloride (PANI-PVC) blends has been studied to see the effect of dopant in the temperature range 300-400 K. Mott's parameters are used to explain the conduction mechanism. Different parameters such as pre-exponential factor (σ 0 ), activation energy (ΔE) and T 0 have also been calculated to see the effect of chemical doping. The crystallinity of the blends is explained on the basis of T 0 . The calculated values of T 0 show that crystallinity increases with an increase of doped PANI in PANI-PVC blends. Fourier transform-infrared (FTIR) spectroscopy is done to explore the nature and interaction of dopant into the polymeric chain

  3. Pipe clamp effects on thin-walled pipe design

    International Nuclear Information System (INIS)

    Lindquist, M.R.

    1980-01-01

    Clamp induced stresses in FFTF piping are sufficiently large to require structural assessment. The basic principles and procedures used in analyzing FFTF piping at clamp support locations for compliance with ASME Code rules are given. Typical results from a three-dimensional shell finite element pipe model with clamp loads applied over the clamp/pipe contact area are shown. Analyses performed to categorize clamp induced piping loads as primary or secondary in nature are described. The ELCLAMP Computer Code, which performs analyses at clamp locations combining clamp induced stresses with stresses from overall piping system loads, is discussed. Grouping and enveloping methods to reduce the number of individual clamp locations requiring analysis are described

  4. Study on the interactions PVC/plasticizers by NMR

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, Maria I.B.; Monteiro, Elisabeth E.C. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Macromoleculas; Harris, Robin [Durham Univ. (United Kingdom). Dept. of Chemistry

    1992-12-31

    The nature of the interactions between PVC and plasticizers as di-butyl phthalate and di-2-ethyl-hexyl phthalate can be investigated using proton/carbon-13 NMR techniques. The measurements of T{sub 1} for protons and carbon-13 and T{sub 1} P for protons can provide a good source of information about the complex behaviour for those two systems which were investigated. (author) 14 refs., 5 figs., 1 tab.

  5. New polyvinyl chloride (PVC) nanocomposite consisting of aromatic polyamide and chitosan modified ZnO nanoparticles with enhanced thermal stability, low heat release rate and improved mechanical properties

    Science.gov (United States)

    Hajibeygi, Mohsen; Maleki, Mahdiye; Shabanian, Meisam; Ducos, Franck; Vahabi, Henri

    2018-05-01

    New ternary nanocomposite systems containing polylvinyl chloride (PVC), chitosan modified ZnO (CMZN) nanoparticles and new synthesized polyamide (PA) were designed and prepared by solution casting method. As a potential reinforcement, CMZN was used in PVC system combined with and without PA. Morphology, mechanical, thermal and combustion properties of the all PVC systems were studied. In the presence of the CMZN, PA showed a synergistic effect on improvement of the all investigated properties of PVC. The 5 mass% loss temperature (T5) was increased from 195 °C to 243 °C in PVC/CMZN-PA nanocomposite containing 1 mass% of each PA and CMZN (PZP 2). The peak of heat release rate was decreased from 131 W/g for PVC to 104 W/g for PVC/CMZN-PA nanocomposite containing 3 mass% of each PA and CMZN (PZP 6). According to the tensile tests, compared to the neat PVC, the tensile strength was increased from 35.4 to 53.4 MPa for PZP 6.

  6. Cyclic Voltammetry of Biopolymer Heparin at PVC Plasticized Liquid Membrane

    Czech Academy of Sciences Publication Activity Database

    Samec, Zdeněk; Trojánek, Antonín; Langmaier, Jan; Samcová, E.

    2003-01-01

    Roč. 5, - (2003), s. 867-870 ISSN 1388-2481 R&D Projects: GA ČR GA203/04/0424 Institutional research plan: CEZ:AV0Z4040901 Keywords : cyclic voltammetry * PVC plasticized liquit membrane * heparin Subject RIV: CG - Electrochemistry Impact factor: 2.300, year: 2003

  7. Optimization of the process of steel strip perforation and nickel platting for the purpose of elimination of trichloroethylene from the cleaning process of perforated steel strip

    Directory of Open Access Journals (Sweden)

    Petrović Aleksandra B.

    2009-01-01

    Full Text Available In the production of pocket type electrodes for Ni-Cd batteries perforation of proper steel strips and then nickel platting of perforated steel strips were made. In the nickel platting process, the organic solvent, trichloroethylene, has previously been used for cleaning. Due to the carcinogenic nature of trichloroethylene and the many operations previously required during cleaning, it was considered to do cleaning of perforated steel strips without use of the mentioned organic solvent. In the purpose of elimination of trichloroethylene from the cleaning process of perforated steel strips, the tests of perforation of steel strips with use of oils of different viscosity were made. It was shown that there was no dysfunction during the work of the perforation plants, meaning there was no additional heating of the strips, deterring of the steel filings, nor excessive wearing of the perforation apparatus. The perforation percent was the same irrelevant of the viscosity of the used oil. Before being perforated using the oils with different viscosity, the nickel platting steel strips were cleaned in different degreasers (based on NaOH as well as on KOH. It was shown that efficient cleaning without the use of trichloroethylene is possible with the use of oil with smaller viscosity in the perforated steel strips process and the degreaser based on KOH in the cleaning process, before nickel platting. It also appeared that the alkali degreaser based on KOH was more efficient, bath corrections were made less often and the working period of the baths was longer, which all in summary means less quantity of chemicals needed for degreasing of perforated steel strips.

  8. Penelitian penggunaan minarex sebagai plasticizer untuk pembuatan kompon slang PVC

    Directory of Open Access Journals (Sweden)

    Niken Karsiati

    1995-12-01

    Full Text Available The objective of the research is to find out the maximum quantity of Minarex as plasticizer which can be added in making compound PVC hose which fulfills the requirements of JIS K. 6771-77 “Flexible Vinyl Tube. Materials used are PVC resin added by additives, i.e DOP, BaCdZn, Stearic Acid, dyes and Minarex as DOP substitution. They all must be mixed and feed to two roll mill homogenizing. Temperature of operational is within 50-800C, roll speed is approximately 10 and 8,6 rpm. Then the compound is moulded into slab form using hydraulic press machine at 1700C, pressure 150 kg/cm2for 10 minutes. The slab is tested its physical properties including tensile strength, elongation at break, tensile strength after accelerated aging, and also observed organoleptically. Based on the research, compound with Minarex substitution 10 parts still conform to JIS K. 6771-77 and the appearance is good.

  9. Desenvolvimento de PVC reforçado com resíduos de Pinus para substituir madeira convencional em diversas aplicações Development of PVC/wood composites for the replacement of conventional wood products

    Directory of Open Access Journals (Sweden)

    Antonio Rodolfo Jr.

    2006-03-01

    Full Text Available Este trabalho avalia a viabilidade técnica da obtenção de compósitos lignocelulósicos de PVC, utilizando-se resíduo de Pinus elliottii e Pinus taeda como carga reforçativa. Foi desenvolvido um processo simples e economicamente viável de tratamento de resíduos industriais desta madeira, processo este baseado na secagem e revestimento das partículas com lubrificantes funcionais e agentes de acoplamento utilizados como aditivos na indústria do PVC, bem como no uso de equipamentos tradicionais da indústria de processamento deste termoplástico. Foram avaliados os efeitos da incorporação da farinha de madeira em concentrações variáveis e do tipo de agente de tratamento superficial utilizado na processabilidade do composto de PVC, bem como em propriedades finais do compósito. Os resultados mostram que o desenvolvimento deste tipo de material compósito é uma alternativa viável para a substituição da madeira convencional em diversas aplicações.This work evaluates the technical viability of lignocellulosic vinyl composites, using residues of Pinus elliottii and Pinus taeda as the reinforcement fiber. A simple and economically viable process for the treatment of these industrial residues was developed. The process includes sieving, drying and treating the wood particles. Treatment is made with functional lubricants and coupling agents used as additives in the PVC industry. Extrusion was performed using traditional equipment available in the Brazilian PVC processing industry. The effect on the processability of the variable concentrations of the residues incorporated and the type of agent used for the treatment had been evaluated, as well as in the final properties of the composite. The results show that the development of this kind of composite material is a viable alternative for the substitution of conventional wood in diverse applications.

  10. Resistance of particleboard panels made of agricultural residues and bonded with synthetic resins or PVC plastic to wood-rotting fungi

    Directory of Open Access Journals (Sweden)

    Divino Eterno Teixeira

    2009-12-01

    Full Text Available This study aims to evaluate the resistance of three types of particleboard panel to biodeterioration, two of which bonded with synthetic resins and one bonded with PVC plastic. Composite panels were made using sugar cane straw particles as raw material which were bonded together with urea-formaldehyde (UF, tannin-formaldehyde (TANI and PVC plastic (PVC resins. Decay tests were performed following procedures outlined in the ASTM D2017-81/1994 standard, whereby sample specimens were subjected to attack by white rot fungus Trametes versicolor and brown rot fungus Gloeophyllum trabeum using pine (Pinus sp. and embaúba (Cecropia sp. as reference timber. Panels bonded with PVC resin were rated ‘resistant’ to attack by both fungi while those bonded with UF and TANI resins were rated ‘slightly resistant’ to their attack.

  11. Fouling Resilient Perforated Feed Spacers for Membrane Filtration

    KAUST Repository

    Kerdi, Sarah

    2018-04-24

    The improvement of feed spacers with optimal geometry remains a key challenge for spiral-wound membrane systems in water treatment due to their impact on the hydrodynamic performance and fouling development. In this work, novel spacer designs are proposed by intrinsically modifying cylindrical filaments through perforations. Three symmetric perforated spacers (1-Hole, 2-Hole, and 3-Hole) were in-house 3D-printed and experimentally evaluated in terms of permeate flux, feed channel pressure drop and membrane fouling. Spacer performance is characterized and compared with standard no perforated (0-Hole) design under constant feed pressure and constant feed flow rate. Perforations in the spacer filaments resulted in significantly lowering the net pressure drop across the spacer filled channel. The 3-Hole spacer was found to have the lowest pressure drop (50% - 61%) compared to 0-Hole spacer for various average flow velocities. Regarding permeate flux production, the 0-Hole spacer produced 5.7 L.m-2.h-1 and 6.6 L.m-2.h-1 steady state flux for constant pressure and constant feed flow rate, respectively. The 1-Hole spacer was found to be the most efficient among the perforated spacers with 75% and 23% increase in permeate production at constant pressure and constant feed flow, respectively. Furthermore, membrane surface of 1-Hole spacer was found to be cleanest in terms of fouling, contributing to maintain higher permeate flux production. Hydrodynamic understanding of these perforated spacers is also quantified by performing Direct Numerical Simulation (DNS). The performance enhancement of these perforated spacers is attributed to the formation of micro-jets in the spacer cell that aided in producing enough unsteadiness/turbulence to clean the membrane surface and mitigate fouling phenomena. In the case of 1-Hole spacer, the unsteadiness intensity at the outlet of micro-jets and the shear stress fluctuations created inside the cells are higher than those observed with

  12. Fouling resilient perforated feed spacers for membrane filtration.

    Science.gov (United States)

    Kerdi, Sarah; Qamar, Adnan; Vrouwenvelder, Johannes S; Ghaffour, Noreddine

    2018-04-24

    The improvement of feed spacers with optimal geometry remains a key challenge for spiral-wound membrane systems in water treatment due to their impact on the hydrodynamic performance and fouling development. In this work, novel spacer designs are proposed by intrinsically modifying cylindrical filaments through perforations. Three symmetric perforated spacers (1-Hole, 2-Hole, and 3-Hole) were in-house 3D-printed and experimentally evaluated in terms of permeate flux, feed channel pressure drop and membrane fouling. Spacer performance is characterized and compared with standard no perforated (0-Hole) design under constant feed pressure and constant feed flow rate. Perforations in the spacer filaments resulted in significantly lowering the net pressure drop across the spacer filled channel. The 3-Hole spacer was found to have the lowest pressure drop (50%-61%) compared to 0-Hole spacer for various average flow velocities. Regarding permeate flux production, the 0-Hole spacer produced 5.7 L m -2 .h -1 and 6.6 L m -2 .h -1 steady state flux for constant pressure and constant feed flow rate, respectively. The 1-Hole spacer was found to be the most efficient among the perforated spacers with 75% and 23% increase in permeate production at constant pressure and constant feed flow, respectively. Furthermore, membrane surface of 1-Hole spacer was found to be cleanest in terms of fouling, contributing to maintain higher permeate flux production. Hydrodynamic understanding of these perforated spacers is also quantified by performing Direct Numerical Simulation (DNS). The performance enhancement of these perforated spacers is attributed to the formation of micro-jets in the spacer cell that aided in producing enough unsteadiness/turbulence to clean the membrane surface and mitigate fouling phenomena. In the case of 1-Hole spacer, the unsteadiness intensity at the outlet of micro-jets and the shear stress fluctuations created inside the cells are higher than those

  13. Karakteristik sifat mekanik, ketahanan api dan pembakaran, dan morfologi nanokomposit campuran PVC dan LDPE

    Directory of Open Access Journals (Sweden)

    Arum Yuniari

    2014-06-01

    Full Text Available The purpose of the study was to determine the effect of addition of low density polyethylene (LDPE and flame retardant on mechanical properties, resistant to fire and burning and morphology from the mixture of polyvinyl chloride (PVC, LDPE, flame retardant, and nanoprecipitated calcium carbonate (NPCC as filler. The materials were mixed in laboplastomill at 215 ºC, torque speed 50 rpm, for 10 minutes. Nanocomposite was prepared by PVC/LDPE variations of 100/15; 100/20; 100/25; and 100/30 phr and flame retardant variations of 30 and 35 phr. The results showed that the hihger of LDPE in nanocomposite increased the hardness and impact resistance, however, it decreased the tensile strength, elongation at break, and density. Addition of flame retardant to the nanocomposites showed good resistance to fire and burning, and optimum mechanical properties were found in using of 35 phr flame retardant.The morphology of the nanocomposite, were observed by Scanning Electron Microscope (SEM confirmed that homogeneous mixture of LDPE dispersed in the PVC matrix.

  14. Nasal Septum Perforation due to Methamphetamine abuse

    Directory of Open Access Journals (Sweden)

    Mehdi Bakhshaee

    2012-07-01

    Full Text Available Introduction: Spontaneous Perforation of the nasal septum is an uncommon condition. Nasal inhalation of substances such as cocaine has long been linked to this Perforation. Case Report: This report describes the case of a 46-year-old woman who was addicted to methamphetamine and who presented with perforation of the nasal septum.This is the first reported case of nasal septal necrosis linked to nasal inhalation of methamphetamine. Conclusions: Patient history and assurance regardingillegal drug consumption and abuse is a key point for fast and accurate diagnosis. The pathophysiology of drug-induced sinunasal disease and a review of the literature are also presented.

  15. Chilled water optimization at Beek INEOS PVC Plant : ammonia cycle

    NARCIS (Netherlands)

    Karami Alaghinloo, B.

    2012-01-01

    In BEEK INEOS PVC plant, polymerization takes place in a suspension process in twenty reactors in five lines. As the reaction is exothermic, a 17MW chilled water unit (CWU) removing heat from reactors which are producing different grades in batch processes. The objective of the project was to

  16. Application of time-of-flight mass spectrometry with laser-based photoionization methods for analytical pyrolysis of PVC

    Energy Technology Data Exchange (ETDEWEB)

    Streibel, T.; Muehlberger, F. [GSF - Forschungszentrum fuer Umwelt und Gesundheit GmbH, Neuherberg (Germany); Adam, T.; Zimmermann, R. [Augsburg Univ. (Germany); Cao, L. [National Center for Iron and Steel, Beijing, BJ (China)

    2004-09-15

    Chlorinated benzenes and phenols generated from PVC pyrolysis are known to be precursors of PCDD/F formation. Therefore, selective and sensitive monitoring of these substances during PVC pyrolysis processes on an on-line, real-time basis could be very useful for the understanding of PCDD/F formation pathways. In this study, we investigated the pyrolysis gas from PVC samples derived from steel recycling by means of simultaneous single photon ionization/resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (SPI/REMPI-TOFMS). The application of these soft photo-ionization techniques in mass spectrometry enables a fast and comprehensive analysis of this complex matrix without generating fragment ions, which would interfere with molecule ions making interpretation of the obtained mass spectra very difficult.

  17. Antibacterial performance of ZnO-based fillers with mesoscale structured morphology in model medical PVC composites

    Energy Technology Data Exchange (ETDEWEB)

    Machovsky, Michal; Kuritka, Ivo, E-mail: ivo@kuritka.net; Bazant, Pavel; Vesela, Daniela; Saha, Petr

    2014-08-01

    Three different ZnO-based antibacterial fillers having different morphologies in microscale region were prepared by the use of the microwave assisted synthesis protocol created in our laboratory with additional annealing in one case. Further, PVC composites containing 0.5–5 wt.% of ZnO based antibacterial fillers were prepared by melt mixing and characterized by scanning electron microscopy (SEM) and X-ray diffractometry (XRD). Mechanical testing showed no adverse effect on the working of polymer composites due to either of the fillers used or the applied processing conditions in comparison with the neat medical grade PVC. The surface antibacterial activity of the compounded PVC composites was assessed against Escherichia coli ATCC 8739 and Staphylococcus aureus ATCC 6538P according to ISO 22196: 2007 (E). All materials at almost all filler loading levels were efficient against both species of bacteria. The material with the most expanding morphology assuring the largest contact between filler and matrix achieved an excellent level of more than 99.9999% reduction of viable cells of E. coli in comparison to untreated PVC and performed very well against S. aureus, too. A correlation between the morphology and efficacy of the filler was observed and, as a result, a general rule was formulated which links the proneness of the microparticles to perform well against bacteria to their shape and morphology. - Highlights: • ZnO-based nanostructured microparticles were prepared by microwave synthesis. • Prepared ZnO imparts excellent antibacterial activity to PVC composites. • The microparticulate character of filler makes it processable as common powders. • The inevitable disadvantages of nanoparticles are circumvented. • General rule of proneness of microparticles for antibacterial composites.

  18. Antibacterial performance of ZnO-based fillers with mesoscale structured morphology in model medical PVC composites

    International Nuclear Information System (INIS)

    Machovsky, Michal; Kuritka, Ivo; Bazant, Pavel; Vesela, Daniela; Saha, Petr

    2014-01-01

    Three different ZnO-based antibacterial fillers having different morphologies in microscale region were prepared by the use of the microwave assisted synthesis protocol created in our laboratory with additional annealing in one case. Further, PVC composites containing 0.5–5 wt.% of ZnO based antibacterial fillers were prepared by melt mixing and characterized by scanning electron microscopy (SEM) and X-ray diffractometry (XRD). Mechanical testing showed no adverse effect on the working of polymer composites due to either of the fillers used or the applied processing conditions in comparison with the neat medical grade PVC. The surface antibacterial activity of the compounded PVC composites was assessed against Escherichia coli ATCC 8739 and Staphylococcus aureus ATCC 6538P according to ISO 22196: 2007 (E). All materials at almost all filler loading levels were efficient against both species of bacteria. The material with the most expanding morphology assuring the largest contact between filler and matrix achieved an excellent level of more than 99.9999% reduction of viable cells of E. coli in comparison to untreated PVC and performed very well against S. aureus, too. A correlation between the morphology and efficacy of the filler was observed and, as a result, a general rule was formulated which links the proneness of the microparticles to perform well against bacteria to their shape and morphology. - Highlights: • ZnO-based nanostructured microparticles were prepared by microwave synthesis. • Prepared ZnO imparts excellent antibacterial activity to PVC composites. • The microparticulate character of filler makes it processable as common powders. • The inevitable disadvantages of nanoparticles are circumvented. • General rule of proneness of microparticles for antibacterial composites

  19. Spectrum of perforation peritonitis in India--review of 504 consecutive cases.

    Science.gov (United States)

    Jhobta, Rajender Singh; Attri, Ashok Kumar; Kaushik, Robin; Sharma, Rajeev; Jhobta, Anupam

    2006-09-05

    Perforation peritonitis is the most common surgical emergency in India. The spectrum of etiology of perforation in Tropical countries continues to be different from its Western counterpart. The objective of the study was to highlight the spectrum of perforation peritonitis as encountered by us at Government Medical College and Hospital (GMCH), Chandigarh. Five hundred and four consecutive cases of perforation peritonitis over a period of five years were reviewed in terms of clinical presentation, operative findings and postoperative course retrospectively at GMCH, Chandigarh. The most common cause of perforation in our series was perforated duodenal ulcer (289 cases) followed by appendicitis (59 cases), gastrointestinal perforation due to blunt trauma abdomen (45 cases), typhoid fever (41 cases) and tuberculosis (20 cases). Despite delay in seeking medical treatment (53%), the overall mortality (10%) was favourably comparable with other published series though the overall morbidity (50%) was unusually high. In contrast to western literature, where lower gastrointestinal tract perforations predominate, upper gastrointestinal tract perforations constitute the majority of cases in India. The increasing incidence of post-traumatic gastro-enteric injuries may be due to an increase in high speed motor vehicle accidents which warrant early recognition and prompt treatment to avoid serious complications and death.

  20. Spectrum of perforation peritonitis in India-review of 504 consecutive cases

    Directory of Open Access Journals (Sweden)

    Sharma Rajeev

    2006-09-01

    Full Text Available Abstract Background/objective Perforation peritonitis is the most common surgical emergency in India. The spectrum of etiology of perforation in Tropical countries continues to be different from its Western counterpart. The objective of the study was to highlight the spectrum of perforation peritonitis as encountered by us at Government Medical College and Hospital (GMCH, Chandigarh. Methods Five hundred and four consecutive cases of perforation peritonitis over a period of five years were reviewed in terms of clinical presentation, operative findings and postoperative course retrospectively at GMCH, Chandigarh. Results The most common cause of perforation in our series was perforated duodenal ulcer (289 cases followed by appendicitis (59 cases, gastrointestinal perforation due to blunt trauma abdomen (45 cases, typhoid fever (41 cases and tuberculosis (20 cases. Despite delay in seeking medical treatment (53%, the overall mortality (10% was favourably comparable with other published series though the overall morbidity (50% was unusually high. Conclusion In contrast to western literature, where lower gastrointestinal tract perforations predominate, upper gastrointestinal tract perforations constitute the majority of cases in India. The increasing incidence of post-traumatic gastro-enteric injuries may be due to an increase in high speed motor vehicle accidents which warrant early recognition and prompt treatment to avoid serious complications and death.

  1. Contact lens rehabilitation following repaired corneal perforations

    Science.gov (United States)

    Titiyal, Jeewan S; Sinha, Rajesh; Sharma, Namrata; Sreenivas, V; Vajpayee, Rasik B

    2006-01-01

    Background Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. Method Eyes that had undergone repair for corneal perforating injuries with or without lens aspiration were fitted rigid gas permeable contact lenses. The fitting pattern and the improvement in visual acuity by contact lens over spectacle correction were noted. Results Forty eyes of 40 patients that had undergone surgical repair of posttraumatic corneal perforations were fitted rigid gas permeable contact lenses for visual rehabilitation. Twenty-four eyes (60%) required aphakic contact lenses. The best corrected visual acuity (BCVA) of ≥ 6/18 in the snellen's acuity chart was seen in 10 (25%) eyes with spectacle correction and 37 (92.5%) eyes with the use of contact lens (p < 0.001). The best-corrected visual acuity with spectacles was 0.20 ± 0.13 while the same with contact lens was 0.58 ± 0.26. All the patients showed an improvement of ≥ 2 lines over spectacles in the snellen's acuity chart with contact lens. Conclusion Rigid gas permeable contact lenses are better means of rehabilitation in eyes that have an irregular cornea due to scars caused by perforating corneal injuries. PMID:16536877

  2. Frequency of wound infection in non-perforated appendicitis with use of single dose perforative antibiotics

    International Nuclear Information System (INIS)

    Ali, K.; Latif, H.; Ahmad, S.

    2015-01-01

    Antibiotics are used both pre and post-operatively in acute appendicitis for preventing wound infection. It has been observed that the routine use of post-operative antibiotics is not necessary in cases of non-perforated appendicitis as only prophylactic antibiotics are sufficient to prevent wound infection. The aim of this study was to see the frequency of wound infection in non-perforated appendicitis with single dose preoperative antibiotics only. Method: This observational study was conducted at the Department of Surgery, Ayub Medical College, Abbottabad from May to November 2014. A total of 121 patients with non-perforated appendicitis were included in the study. Only single dose preoperative antibiotics were used. The patients were followed for wound infection till 8th post-operative day. Results: 121 patients, 56(46.28%) male and 65(53.72%) female were included in the study. The mean age of patients was 27.41 ± 7.12 years with an age range of 18 to 45 years. In the entire series, 7(5.78%) patients developed wound infection. The infection was minor which settled with conservative therapy. Prophylactic antibiotics were found efficacious in 114(94.21%) patients. There was no significant association between wound infection and age and gender. Conclusion: Single dose preoperative antibiotics were found effective in controlling post-operative wound infection without the need of extending the antibiotics to post-operative period in cases of non-perforated appendicitis. (author)

  3. Dosimetry of the JS-6500 industrial irradiator for the irradiation of the PVC graduated flasks; Dosimetria del irradiador industrial JS-6500 para la irradiacion de probetas de PVC

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda F, A.; Carrasco A, H.; Martinez P, M.E. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The dosimetry of the JS-6500 AECL irradiator was realized, outside of the industrial transportation rails to know the dose distribution, as well as its dose speed. This one with the intention of exposing to gamma radiation; plastified PVC graduated flasks and evaluating their interweavement or degradation or both. This study of dosimetry was carried out by means of a theoretical and experimental evaluation in air atmosphere. The results allow to know the irradiation conditions of the PVC graduated flasks as well as those results prove that has not a significant difference among the obtained result as theoretical as experimentally due to that the obtained result in the theoretical evaluation is 2.62 KGy/h and the result for the case of the experimental evaluation is 2.74 KGy/h. (Author)

  4. Preoperative chest x-ray findings in peptic ulcer perforation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. H.; Kim, S. W.; Lim, J. S.; Kim, Y. J. [Kyungpook National University School of Medicine, Taegu (Korea, Republic of)

    1981-12-15

    This study was carried out to analyze the distribution of age, sex, chief complaint, physical examination and findings of chest x-ray films before operation in 59 cases of peptic ulcer perforation. The ratio of male to female was 1.7 : 1 and incidence of the ulcer perforation was most common in 5th decades. Thirty five among 59 cases showed pleural effusion, segmental atelectasis and pneumonic infiltration on chest x-ray film. Twenty nine among 50 cases of duodenal ulcer perforation and 6 of 9 cases of stomach ulcer perforation showed positive chest x-ray findings. No relationship was found between fever and preoperative chest x-ray findings.

  5. Preoperative chest x-ray findings in peptic ulcer perforation

    International Nuclear Information System (INIS)

    Kim, T. H.; Kim, S. W.; Lim, J. S.; Kim, Y. J.

    1981-01-01

    This study was carried out to analyze the distribution of age, sex, chief complaint, physical examination and findings of chest x-ray films before operation in 59 cases of peptic ulcer perforation. The ratio of male to female was 1.7 : 1 and incidence of the ulcer perforation was most common in 5th decades. Thirty five among 59 cases showed pleural effusion, segmental atelectasis and pneumonic infiltration on chest x-ray film. Twenty nine among 50 cases of duodenal ulcer perforation and 6 of 9 cases of stomach ulcer perforation showed positive chest x-ray findings. No relationship was found between fever and preoperative chest x-ray findings

  6. Prediction of inelastic behavior and creep-fatigue life of perforated plates

    International Nuclear Information System (INIS)

    Igari, Toshihide; Setoguchi, Katsuya; Nakano, Shohki; Nomura, Shinichi

    1991-01-01

    Prediction methods of macroscopic and local stress-strain behavior of perforated plates in plastic and creep regime which are proposed by the authors are applied to the inelastic analysis and creep-fatigue life prediction of perforated cylinder subjected to cyclic thermal stress. Stress-strain behavior of perforated cylinder is analyzed by modeling the perforated portion to cylinder with equivalent-solid-plate properties. Creep-fatigue lives at around a hole of perforated plates are predicted by using the local stress-strain behavior and are compared with experimentally observed lives. (author)

  7. Production of pre-basic potato seed by polyvinyl chloride PVC: articulate gutters hydroponic system

    Directory of Open Access Journals (Sweden)

    Jonny Everson Scherwinski-Pereira

    2009-10-01

    Full Text Available The development of more efficient and productive systems for pre-basic seed potato production would improve the quality of the propagative material used by the potato growers, directly affecting the crop yields. A two-year experiment was carried out to evaluate the potato pre-basic seed production by two types of hydroponic systems (fibrocement tiles and articulated PVC gutters, two cultivars (`Baronesa` and `Eliza` and two types of propagative material (plants coming from in vitro culture and minitubers. The PVC gutters system was highly efficient. When using minitubers, this system reached multiplication rates up to 74 tubers per plant. Minitubers were more productive than in vitro plants, independent of cultivar and hydroponic system utilized.Um experimento realizado por dois anos consecutivos avaliou a produção de sementes pré-básicas de batata por meio de sistemas de cultivo hidropônico. O trabalho testou a combinação de dois sistemas de cultivo (telha de fibrocimento e calhas de PVC articuladas, duas cultivares (Baronesa e Eliza e dois tipos de material propagativo (plântulas oriundas do cultivo in vitro e minitubérculos. O sistema de calhas de PVC foi altamente eficiente. Quando foi utilizado minitubérculos, este sistema alcançou taxas de multiplicação de até 74 tubérculos por planta. De modo geral, o uso de minitubérculos como material propagativo apresentou os melhores resultados de produtividade quando comparada ao material in vitro, independentemente da cultivar e sistemas hidropônicos utilizados.

  8. PVC gel soft actuator-based wearable assist wear for hip joint support during walking

    Science.gov (United States)

    Li, Yi; Hashimoto, Minoru

    2017-12-01

    Plasticized polyvinyl chloride (PVC) gel and mesh electrode-based soft actuators have considerable potential to provide new types of artificial muscle, exhibiting similar responsiveness to biological muscle in air, >10% deformation, >90 kPa output stress, variable stiffness, long cycle life (>5 million cycles), and low power consumption. We have designed and fabricated a prototype of walking assist wear using the PVC gel actuator in previous study. The system has several advantages compared with traditional motor-based exoskeletons, including lower weight and power consumption, and no requirement for rigid external structures that constrain the wearer’s joints. In this study, we designed and established a control and power system to making the whole system portable and wearable outdoors. And we designed two control strategies based on the characteristics of the assist wear and the biological kinematics. In a preliminary experimental evaluation, a hemiparetic stroke patient performed a 10 m to-and-fro straight line walking task with and without assist wear on the affected side. We found that the assist wear enabled natural movement, increasing step length and decreasing muscular activity during straight line walking. We demonstrated that the assistance effect could be adjusted by controlling the on-off time of the PVC gel soft actuators. The results show the effectiveness of the proposed system and suggest the feasibility of PVC gel soft actuators for developing practical soft wearable assistive devices, informing the development of future wearable robots and the other soft actuator technologies for human movement assistance and rehabilitation.

  9. Effect of complexing salt on conductivity of PVC/PEO polymer blend ...

    Indian Academy of Sciences (India)

    Administrator

    composite polymer, a blend-based polymer electrolyte, composed of two conductive ... LiClO4 electrolytes with various methacrylic and acrylic polymers used as additives .... Z real vs Z imaginary plot for PVC : PEO : LiBF4 at room temperature.

  10. Primary Closure versus Gastric Resection for Perforated Gastric

    African Journals Online (AJOL)

    Perforated gastric ulcer is one of the most life‑threatening complications of peptic ulcer disease with high .... tubes were removed and oral nutrition resumed. The .... surgical approach for perforated gastric cancer: One‑stage vs. two‑stage ...

  11. Study on Dynamic Response of Downhole Tools under Perforation Impact Load

    Directory of Open Access Journals (Sweden)

    Liu Jun

    2017-01-01

    Full Text Available A model of a multibody system is established to investigate the dynamic response of an oil tube-shock absorber-perforating gun system in downhole perforation-test joint operation. In the model, the oil tube and perforating gun are modeled as elastic rods and the shock absorber is modeled as single particle system with damping and a spring. Two force continuity conditions are used to simulate the interactions among the three components. The perforation impact load is determined by an experiment of underwater explosion of perforating bullets. Using the model, the effects of charge quantity of perforating bullet, the number of shock absorbers, and the length of oil tube on the dynamic response of oil tube and packer are investigated. On this basis, a basic principle of the combination design of shock absorber and oil tube is proposed to improve the mechanical state of downhole tools. The study results can provide theoretical support for the design of downhole perforation-test joint operation.

  12. Clinical Factors of Delayed Perforation after Endoscopic Submucosal Dissection for Gastric Neoplasms

    Directory of Open Access Journals (Sweden)

    Yoshinobu Yamamoto

    2017-01-01

    Full Text Available Background. Delayed perforation is a rare but severe complication of endoscopic submucosal dissection (ESD for early gastric neoplasm (EGN. The aim of this study was to clarify clinical factors related to delayed perforation after ESD. Methods. A total of 1158 consecutive patients with 1199 EGNs underwent ESD at our hospital between January 2000 and December 2015. Univariate analysis was used to identify clinicopathological factors related to delayed perforation. Moreover, duration of cautery needed for hemostasis was measured by comparison between perforated and nonperforated points in patients with delayed perforation. Results. Delayed perforation occurred in 5 of 1158 consecutive patients with 1199 EGNs who underwent ESD (0.42%. All cases were diagnosed within 24 h after ESD and recovered with conservative management. On univariate analysis, location in the upper stomach was the factor most significantly associated with delayed perforation (P<0.01. Duration of cautery needed for hemostasis was significantly longer at perforated points (9 s than at nonperforated points (3.5 s in five patients. Conclusions. Location in the upper stomach was the risk factor most prominently associated with delayed perforation after ESD for EGNs. In addition, delayed perforation appears associated with excessive electrocautery for hemostasis.

  13. Clinicopathological Analysis of Factors Related to Colorectal Tumor Perforation

    OpenAIRE

    Medina-Arana, Vicente; Martínez-Riera, Antonio; Delgado-Plasencia, Luciano; Rodríguez-González, Diana; Bravo-Gutiérrez, Alberto; Álvarez-Argüelles, Hugo; Alarcó-Hernández, Antonio; Salido-Ruiz, Eduardo; Fernández-Peralta, Antonia M.; González-Aguilera, Juan J.

    2015-01-01

    Abstract Colorectal tumor perforation is a life-threatening complication of this disease. However, little is known about the anatomopathological factors or pathophysiologic mechanisms involved. Pathological and immunohistochemical analysis of factors related with tumoral neo-angiogenesis, which could influence tumor perforation are assessed in this study. A retrospective study of patients with perforated colon tumors (Group P) and T4a nonperforated (controls) was conducted between 2001 and 20...

  14. Predictors of appendiceal perforation in an equal access system.

    Science.gov (United States)

    Walker, Avery; Hatch, Quinton; Drake, Thurston; Nelson, Daniel W; Fitzpatrick, Emilie; Bingham, Jason; Black, George; Maykel, Justin A; Steele, Scott R

    2014-07-01

    Discrepancies in socioeconomic factors have been associated with higher rates of perforated appendicitis. As an equal-access health care system theoretically removes these barriers, we aimed to determine if remaining differences in demographics, education, and pay result in disparate outcomes in the rate of perforated appendicitis. All patients undergoing appendectomy for acute appendicitis (November 2004-October 2009) at a tertiary care equal access institution were categorized by demographics and perioperative data. Rank of the sponsor was used as a surrogate for economic status. A multivariate logistic regression model was performed to determine patient and clinical characteristics associated with perforated appendicitis. A total of 680 patients (mean age 30±16 y; 37% female) were included. The majority were Caucasian (56.4% [n=384]; African Americans 5.6% [n=38]; Asians 1.9% [n=13]; and other 48.9% [n=245]) and enlisted (87.2%). Overall, 6.4% presented with perforation, with rates of 6.6%, 5.8%, and 6.7% (P=0.96) for officers, enlisted soldiers, and contractors, respectively. There was no difference in perforation when stratified by junior or senior status for either officers or enlisted (9.3% junior versus 4.40% senior officers, P=0.273; 6.60% junior versus 5.50% senior enlisted, P=0.369). On multivariate analysis, parameters such as leukocytosis and temperature, as well as race and rank were not associated with perforation (P=0.7). Only age had a correlation, with individuals aged 66-75 y having higher perforation rates (odds ratio, 1.04; 95% confidence interval, 1.02-1.05; P<0.001). In an equal-access health care system, older age, not socioeconomic factors, correlated with increased appendiceal perforation rates. Published by Elsevier Inc.

  15. Monitoring a PVC batch process with multivariate statistical process control charts

    NARCIS (Netherlands)

    Tates, A. A.; Louwerse, D. J.; Smilde, A. K.; Koot, G. L. M.; Berndt, H.

    1999-01-01

    Multivariate statistical process control charts (MSPC charts) are developed for the industrial batch production process of poly(vinyl chloride) (PVC). With these MSPC charts different types of abnormal batch behavior were detected on-line. With batch contribution plots, the probable causes of these

  16. Nuclear piping and pipe support design and operability relating to loadings and small bore piping

    International Nuclear Information System (INIS)

    Stout, D.H.; Tubbs, J.M.; Callaway, W.O.; Tang, H.T.; Van Duyne, D.A.

    1994-01-01

    The present nuclear piping system design practices for loadings, multiple support design and small bore piping evaluation are overly conservative. The paper discusses the results developed for realistic definitions of loadings and loading combinations with methodology for combining loads under various conditions for supports and multiple support design. The paper also discusses a simplified method developed for performing deadweight and thermal evaluations of small bore piping systems. Although the simplified method is oriented towards the qualification of piping in older plants, this approach is applicable to plants designed to any edition of the ASME Section III or B31.1 piping codes

  17. Properties of commercial PVC-films with respect to electron dosimetry

    International Nuclear Information System (INIS)

    Miller, A.; Liqing, X.

    1985-05-01

    The properties of three commercially available polyvinyl chloride (PVC) film supplies and one made without additives were tested with respects to their application as routine dose monitors at electron accelerators. Dose fractionation was found to increase the response and the post-irradiation heat treatment was very critical for some of the films. (author)

  18. Armazenamento de atemoias (Annona squamosa x Annona cherimola recobertas com filme PVC

    Directory of Open Access Journals (Sweden)

    P. A. de Souza

    2015-12-01

    Full Text Available A atemoia, assim como todos os frutos climatéricos, apresenta uma elevada perecibilidade, tornando-se importante a adoção de técnicas pós-colheita. Este trabalho teve como objetivo avaliar o armazenamento de atemoias recobertas com filme PVC. Os frutos utilizados foram da variedade ‘Gefner’ apresentando-se em estado de maturação verde-maduro. Estes foram transferidos para o laboratório de Química de Alimentos do IFCE, submetidos à higienização e divididos nos devidos tratamentos. O primeiro tratamento constou no armazenamento de cinco frutos em bandejas de isopor recobertos com filme PVC. O segundo, do recobrimento individual dos frutos em filme PVC, sendo estes acondicionados em bandejas de isopor e os frutos do controle. Estes foram armazenados durante 8 dias. O delineamento utilizado foi o DIC em esquema fatorial 3x4 com quatro repetições de cinco frutos por parcela. A cada tempo de armazenamento foram avaliadas: perda de massa, sólidos solúveis, acidez titulável, Ratio, pH e índice de rachaduras. O uso de filme plástico reduz a perda de massa, porém retarda o amadurecimento de frutos de atemoia. As rachaduras estão diretamente associadas ao amadurecimento dos frutos, ao aumento dos teores de sólidos solúveis e possivelmente a cultivar avaliada. Storage of atemoyas (Annona squamosa x Annona cherimola covered with PVC filmAbstract: The atemoya, as well as all climacteric fruits, is highly perishable, becoming important to adopt post-harvest techniques. This work aimed to evaluate the atemoyas storage covered with plastic wrap. The fruits used were of the variety 'Gefner' presenting itself in a state of green-mature aging. These were transferred to the Food Chemistry Lab IFCE submitted to cleaning and divided in appropriate treatments. The first treatment consisted in five fruit storage in styrofoam trays covered with plastic wrap. The second, the individual coating of the fruits in PVC film, which are packed in

  19. Influence of operating microscope in the sealing of cervical perforations.

    Science.gov (United States)

    Schmidt, Bruna Schwingel; Zaccara, Ivana Maria; Reis Só, Marcus Vinícius; Kuga, Milton Carlos; Palma-Dibb, Regina Guenka; Kopper, Patrícia Maria Poli

    2016-01-01

    Accidental root canal perforations are among the main complications of endodontic treatment. This study evaluated the influence of operating microscope (OM) in the marginal adaptation of mineral trioxide aggregate (MTA) (Angelus(®)) and glass ionomer (Vitremer) inserted into cervical perforations. Perforations were made in the cervical third of the buccal wall of the root canal in mandibular incisors. Next, the teeth were divided into four groups (N = 10): MG - MTA without OM; VG - Vitremer without OM; MOMG - MTA with OM; VOMG - Vitremer with OM. The perforations were sealed according to the group and the teeth were prepared for analysis by confocal laser scanning microscope. Images of perforation region (1,024×) were made and the gap presented by the materials was measured using the Image J program. LEXT OLS4100 three dimensional (3D) measuring laser microscope measured the volumetric misfit. Data of gap were analyzed by Kruskal-Wallis and Dunn's tests. Analysis of variance (ANOVA) and Tukey's tests compared the volumetric misfits. The results showed lower volume and gap in the interface dentin/material in VOMG compared to the other groups (P < 0.05). The use of OM improved the quality of cervical perforations sealed with Vitremer, being indicated in clinical situations of iatrogenic cervical perforations.

  20. Laparoscopic Primary Colorrhaphy for Acute Iatrogenic Perforations during Colonoscopy

    Directory of Open Access Journals (Sweden)

    Eric M. Haas

    2013-01-01

    Full Text Available Purpose. We present our experience with laparoscopic colorrhaphy as definitive surgical modality for the management of colonoscopic perforations. Methods. Over a 17-month period, we assessed the outcomes of consecutive patients presenting with acute colonoscopic perforations. Patient characteristics and perioperative parameters were tabulated. Postoperative outcomes were evaluated within 30 days following discharge. Results. Five female patients with a mean age of 71.4 ± 9.7 years (range: 58–83, mean BMI of 26.4 ± 3.4 kg/m2 (range: 21.3–30.9, and median ASA score of 2 (range: 2-3 presented with acute colonoscopic perforations. All perforations were successfully managed through laparoscopic colorrhaphy within 24 hours of development. The perforations were secondary to direct trauma (n=3 or thermal injury (n=2 and were localized to the sigmoid (n=4 or cecum (n=1. None of the patients required surgical resection, diversion, or conversion to an open procedure. No intra- or postoperative complications were encountered. The mean length of hospital stay was 3.8 ± 0.8 days (range: 3–5. There were no readmissions or reoperations. Conclusion. Acute colonoscopic perforations can be safely managed via laparoscopic primary repair without requiring resection or diversion. Early recognition and intervention are essential for successful outcomes.

  1. Esophageal Perforation due to Transesophageal Echocardiogram: New Endoscopic Clip Treatment

    Directory of Open Access Journals (Sweden)

    John Robotis

    2014-07-01

    Full Text Available Esophageal perforation due to transesophageal echocardiogram (TEE during cardiac surgery is rare. A 72-year-old female underwent TEE during an operation for aortic valve replacement. Further, the patient presented hematemesis. Gastroscopy revealed an esophageal bleeding ulcer. Endoscopic therapy was successful. Although a CT scan excluded perforation, the patient became febrile, and a second gastroscopy revealed a big perforation at the site of ulcer. The patient's clinical condition required endoscopic intervention with a new OTSC® clip (Ovesco Endoscopy, Tübingen, Germany. The perforation was successfully sealed. The patient remained on intravenous antibiotics, proton pump inhibitors and parenteral nutrition for few days, followed by enteral feeding. She was discharged fully recovered 3 months later. We clearly demonstrate an effective, less invasive treatment of an esophageal perforation with a new endoscopic clip.

  2. Closure report for underground storage tank 141-R3U1 and its associated underground piping

    Energy Technology Data Exchange (ETDEWEB)

    Mallon, B.J.; Blake, R.G.

    1994-03-01

    Underground storage tank UST 141-R3U1 at Lawrence Livermore National Laboratory (LLNL), was registered with the State Water Resources Control Board on June 27, 1984. This tank system consisted of a concrete tank, lined with polyvinyl chloride, and approximately 100 feet of PVC underground piping. UST 141-R3U1 had a capacity of 450 gallons. The underground piping connected three floor drains and one sink inside Building 141 to UST 141-R3U1. The wastewater collected in UST 141-R3U1 contained organic solvents, metals, and inorganic acids. On November 30, 1987, the 141-R3U1 tank system failed a precision tank test. The 141-R3U1 tank system was subsequently emptied and removed from service pending further precision tests to determine the location of the leak within the tank system. A precision tank test on February 5, 1988, was performed to confirm the November 30, 1987 test. Four additional precision tests were performed on this tank system between February 25, 1988, and March 6, 1988. The leak was located where the inlet piping from Building 141 penetrates the concrete side of UST 141-R3U1. The volume of wastewater that entered the backfill and soil around and/or beneath UST 141-R3U1 is unknown. On December 13, 1989, the LLNL Environmental Restoration Division submitted a plan to close UST 141-R3U1 and its associated piping to the Alameda County Department of Environmental Health. UST 141-R3U1 was closed as an UST, and shall be used instead as additional secondary containment for two aboveground storage tanks.

  3. Closure report for underground storage tank 141-R3U1 and its associated underground piping

    International Nuclear Information System (INIS)

    Mallon, B.J.; Blake, R.G.

    1994-03-01

    Underground storage tank UST 141-R3U1 at Lawrence Livermore National Laboratory (LLNL), was registered with the State Water Resources Control Board on June 27, 1984. This tank system consisted of a concrete tank, lined with polyvinyl chloride, and approximately 100 feet of PVC underground piping. UST 141-R3U1 had a capacity of 450 gallons. The underground piping connected three floor drains and one sink inside Building 141 to UST 141-R3U1. The wastewater collected in UST 141-R3U1 contained organic solvents, metals, and inorganic acids. On November 30, 1987, the 141-R3U1 tank system failed a precision tank test. The 141-R3U1 tank system was subsequently emptied and removed from service pending further precision tests to determine the location of the leak within the tank system. A precision tank test on February 5, 1988, was performed to confirm the November 30, 1987 test. Four additional precision tests were performed on this tank system between February 25, 1988, and March 6, 1988. The leak was located where the inlet piping from Building 141 penetrates the concrete side of UST 141-R3U1. The volume of wastewater that entered the backfill and soil around and/or beneath UST 141-R3U1 is unknown. On December 13, 1989, the LLNL Environmental Restoration Division submitted a plan to close UST 141-R3U1 and its associated piping to the Alameda County Department of Environmental Health. UST 141-R3U1 was closed as an UST, and shall be used instead as additional secondary containment for two aboveground storage tanks

  4. Perforated duodenal diverticulum caused by Bezoar: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Jung; Moon, Sung Kyoung; Park, Seong Jin; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae [Dept. of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    2013-11-15

    Duodenal diverticulum is common, but its perforation is a rare complication. Duodenal diverticulum perforation requires prompt treatments because of its high mortality rate. However, an accurate diagnosis is difficult to make due to nonspecific symptoms and signs. It can be misdiagnosed as pancreatitis, cholecystitis, or peptic ulcer. Herein, we report a case of perforated duodenal diverticulum caused by bezoar in a 33-year-old woman whom was diagnosed by abdomen computed tomography and ultrasonography.

  5. Duodenal perforation: an unusual complication of sickle cell anemia

    OpenAIRE

    Acıpayam, Can; Aldıç, Güliz; Akçora, Bülent; Çelikkaya, Mehmet Emin; Aşkar, Hasan; Dorum, Bayram Ali

    2014-01-01

    Duodenal perforation in childhood is a rare condition with a high mortality rate if not treated surgically. Primary gastroduodenal perforation is frequently associated with peptic ulcer and exhibits a positive family history. Helicobacter pylorus is the most significant agent. Secondary gastroduodenal perforation may be a finding of specific diseases, such as Crohn disease, or more rarely may be associated with diseases such as cystic fibrosis or sickle cell anemia. A 14-year-old boy presente...

  6. Spectrum of Perforation Peritonitis in Delhi: 77 Cases Experience

    OpenAIRE

    Yadav, Dinesh; Garg, Puneet K.

    2012-01-01

    Perforation peritonitis is the most common surgical emergency encountered by surgeons all over the world as well in India. The spectrum of etiology of perforation peritonitis in tropical countries continues to differ from its western counterpart. This study was conducted at Hindu Rao Hospital, Municipal Corporation of Delhi, New Delhi, India, designed to highlight the spectrum of perforation peritonitis in the eastern countries and to improve its outcome. This prospective study included 77 co...

  7. Perforated duodenal diverticulum caused by Bezoar: A case report

    International Nuclear Information System (INIS)

    Lee, Eun Jung; Moon, Sung Kyoung; Park, Seong Jin; Lim, Joo Won; Lee, Dong Ho; Ko, Young Tae

    2013-01-01

    Duodenal diverticulum is common, but its perforation is a rare complication. Duodenal diverticulum perforation requires prompt treatments because of its high mortality rate. However, an accurate diagnosis is difficult to make due to nonspecific symptoms and signs. It can be misdiagnosed as pancreatitis, cholecystitis, or peptic ulcer. Herein, we report a case of perforated duodenal diverticulum caused by bezoar in a 33-year-old woman whom was diagnosed by abdomen computed tomography and ultrasonography.

  8. Perforated peptic ulcer

    Science.gov (United States)

    Søreide, Kjetil; Thorsen, Kenneth; Harrison, Ewen M.; Bingener, Juliane; Møller, Morten H.; Ohene-Yeboah, Michael; Søreide, Jon Arne

    2015-01-01

    Summary Perforated peptic ulcer (PPU) is a frequent emergency condition worldwide with associated mortality up to 30%. A paucity of studies on PPU limits the knowledge base for clinical decision-making, but a few randomised trials are available. While Helicobacter pylori and use of non-steroidal anti-inflammatory drugs are frequent causes of PPU, demographic differences in age, gender, perforation location and aetiology exist between countries, as do mortality rates. Clinical prediction rules are used, but accuracy varies with study population. Early surgery, either by laparoscopic or open repair, and proper sepsis management are essential for good outcome. Selected patients can perhaps be managed non-operatively or with novel endoscopic approaches, but validation in trials is needed. Quality of care, sepsis care-bundles and postoperative monitoring need further evaluation. Adequate trials with low risk of bias are urgently needed for better evidence. Here we summarize the evidence for PPU management and identify directions for future clinical research. PMID:26460663

  9. Surgical management of perforated duodenal ulcer: the changing scene.

    Science.gov (United States)

    Plummer, J M; McFarlane, M E C; Newnham

    2004-12-01

    To determine the management of perforated duodenal ulcer at the University Hospital of the West Indies (UHWI) in this era of Helicobacter pylori, the medical records of all patients seen at the UHWI during the period July 1997 to June 2002 with an intra-operative diagnosis of perforated peptic ulcer were reviewed The records were analyzed for the following: age, gender, duration of symptoms, non-steroidal anti-inflammatory drug (NSAID) use, smoking status, operative repair duration of hospitalization, Helicobacter pylori status and medical therapy, peri-operative complications, mortality and recurrence. Ninety per cent of the cases were males. All females in whom perforation occurred were age 50 years and older compared to males where 58% of cases presented before age 50 years. Perforations in acute ulcers occurred in 80% of cases. The majority of patients were male smokers. Non-steroidal anti-inflammatory drug use was also an important risk factor in elderly females. Simple surgical closure and standard triple therapy antibiotics to eradicate Helicobacter pylori was the most common treatment offered. Mortality was one per cent and follow-up poor but 11% of patients had documented recurrent peptic ulceration. In this study population, perforated duodenal ulcer occured overwhelmingly in males less than 50 years of age. There is a trend towards exclusive simple surgical closure and H pylori eradication at the UHWI for patients with perforated duodenal ulcer but this needs to be supported by documentation of H pylori prevalence in the population of patients presenting with perforated peptic ulcers.

  10. Factors related to persisting perforations after ventilation tube insertion.

    Science.gov (United States)

    O'Connell Ferster, Ashley P; Tanner, April Michelle; Karikari, Kodjo; Roberts, Christopher; Wiltz, Derek; Carr, Michele M

    2016-02-01

    Over a million ventilation tubes are placed annually in the United States, making this one of the most commonly performed procedures in the field of medicine. Certain factors increase the risk of persistent tympanic membrane perforation following the extrusion of short term ventilation tubes. Persistent perforations may fail to heal on their own, necessitating surgical closure to avoid conductive hearing loss. It is important to detect factors that may predict children who are at increased risk for persistent perforations. This study was a retrospective chart review that involved 757 patients between 2003 and 2008. The patients studied were within the age of 2 months-17 years, and all had short term tubes placed. The chart data also included demographic information, comorbidities, and information related to tube insertion and follow-up care. Chi-square, t-test, and multivariate logistic regression were conducted to compare variables between patients with perforations and those without. Data from 757 patients was analyzed, showing that perforation rate is associated with rhinorrhea, operative tube removal, aural polyps, and otorrhea (OR 1.72, 8.16, 4.69, and 1.72 respectively). The absence of otorrhea decreased the likelihood of TM perforations and no significant differences were found in gender, total number of sets of tubes, type of tube, use of nasal steroids, adenoidectomy, or nasal congestion. Our findings suggest that children with rhinorrhea, otorrhea, aural polyps, or prolonged intubation requiring operative tube removal should be identified clinically as children at risk of persisting perforation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Common Bile Duct Perforation Due to Tuberculosis: A Case Report

    OpenAIRE

    Razman Jarmin; Shaharin Shaharuddin

    2004-01-01

    A young man with HIV presented with biliary peritonitis secondary to spontaneous common bile duct perforation. Investigation revealed that the perforation was due to Mycobacterium tuberculosis. Tuberculosis of the bile duct is uncommon and usually presents with obstructive jaundice due to stricture. Bile duct perforation due to tuberculosis is extremely rare. Its management is discussed.

  12. Spectrum of perforation peritonitis in India-review of 504 consecutive cases

    OpenAIRE

    Jhobta, Rajender Singh; Attri, Ashok Kumar; Kaushik, Robin; Sharma, Rajeev; Jhobta, Anupam

    2006-01-01

    Abstract Background/objective Perforation peritonitis is the most common surgical emergency in India. The spectrum of etiology of perforation in Tropical countries continues to be different from its Western counterpart. The objective of the study was to highlight the spectrum of perforation peritonitis as encountered by us at Government Medical College and Hospital (GMCH), Chandigarh. Methods Five hundred and four consecutive cases of perforation peritonitis over a period of five years were r...

  13. Diaphragmatic eventration complicated by gastric volvulus with perforation

    OpenAIRE

    Gupta, V; Chandra, A; Gupta, P

    2012-01-01

    Eventration of the diaphragm with gastric volvulus is uncommon. Gastric perforation in these cases is rare and usually associated with acute gastric volvulus with strangulation. We describe a case of diaphragmatic eventration with chronic gastric volvulus with gastric perforation without strangulation in an elderly man.

  14. Common Bile Duct Perforation Due to Tuberculosis: A Case Report

    Directory of Open Access Journals (Sweden)

    Razman Jarmin

    2004-10-01

    Full Text Available A young man with HIV presented with biliary peritonitis secondary to spontaneous common bile duct perforation. Investigation revealed that the perforation was due to Mycobacterium tuberculosis. Tuberculosis of the bile duct is uncommon and usually presents with obstructive jaundice due to stricture. Bile duct perforation due to tuberculosis is extremely rare. Its management is discussed.

  15. Preoperative factors influencing mortality and morbidity in peptic ulcer perforation.

    Science.gov (United States)

    Sivaram, P; Sreekumar, A

    2018-04-01

    Perforated peptic ulcer is one of the most common surgical emergencies worldwide. With the improvement in medical therapy for peptic ulcers, the number of elective surgical procedures has come down. However, the incidence of perforated peptic ulcer is still increasing and remains as a substantial health problem with significant postoperative morbidity and mortality. This study aimed to find out the association between various preoperative and intraoperative factors with the postoperative mortality and morbidity in patients operated for peptic ulcer perforation. This prospective observational study had a time based sample of 101 perforation peritonitis cases admitted to the surgical wards of a tertiary care center from February 2015 to January 2016 who underwent laparotomy, diagnosed to have peptic ulcer perforation and underwent simple closure with an omental patch. Data regarding age, gender, presenting complaints, time elapsed from the onset of symptoms to surgery, physical examination findings, comorbid diseases, laboratory and imaging findings, intraoperative findings, length of hospital stay, postoperative morbidity, and mortality were recorded and analyzed. Female gender, older age group, perforation surgery interval more than 36 h, and size of perforation more than 1 cm 2 were found to be significant factors influencing postoperative mortality and morbidity. Postoperative morbidity was also associated with comorbid diseases. Abnormal renal function on presentation was identified as an additional risk factor for postoperative morbidity and longer hospital stay. An understanding of these factors, identification of patients at risk and early intervention can help in reducing the postoperative morbidity and mortality in peptic ulcer perforation.

  16. Jejunal Diverticular Perforation due to Enterolith

    Directory of Open Access Journals (Sweden)

    Ronaldo Nonose

    2011-08-01

    Full Text Available Jejunal diverticulosis is a rare entity with variable clinical and anatomical presentations. Although there is no consensus on the management of asymptomatic jejunal diverticular disease, some complications are potentially life-threatening and require early surgical treatment. Small bowel perforation secondary to jejunal diverticulitis by enteroliths is rare. The aim of this study was to report a case of small intestinal perforation caused by a large jejunal enterolith. An 86-year-old woman was admitted with signs of diffuse peritonitis. After initial fluid recovery the patient underwent emergency laparotomy. The surgery showed that she had small bowel diverticular disease, mainly localized in the proximal jejunum. The peritonitis was due to intestinal perforation caused by an enterolith 12 cm in length, localized inside one of these diverticula. The intestinal segment containing the perforated diverticulum with the enterolith was removed and an end-to-end anastomosis was done to reconstruct the intestinal transit. The patient recovered well and was discharged from hospital on the 5th postoperative day. There were no signs of abdominal pain 1 year after the surgical procedure. Although jejunal diverticular disease with its complications, such as formation of enteroliths, is difficult to suspect in patients with peritonitis, it should be considered as a possible source of abdominal infection in the elderly patient when more common diagnoses have been excluded.

  17. Sonographic templates of newborn perforator stroke.

    Science.gov (United States)

    Abels, Lyanne; Lequin, Maarten; Govaert, Paul

    2006-07-01

    Many paediatric strokes occur in the perinatal period. Improvement in neuroimaging has increased detection in newborns with neurological symptoms. To define sonographic templates of neonatal stroke in the territory of perforators of the anterior choroidal artery (AChA) and the anterior (ACA), middle (MCA) and posterior (PCA) cerebral arteries. In 24 neonates with perforator stroke, we retrospectively studied antenatal and perinatal events. Brain sonography was performed with an 8.5-MHz probe. Only hyperechoic lesions in the thalamus and/or striatum and/or centrum semiovale were included. MRI was obtained using a 1.5-T machine. We detected 28 perforator strokes in 24 infants (6 preterm): 5 MCA medial striate, 8 MCA lateral striate, 3 MCA centrum semiovale, 4 ACA Heubner's, 5 PCA thalamic arteries, 1 AChA, and 2 hypothalamic perforators. We attributed clinical seizures to stroke in two infants only. Catheter-related embolism (certain in three, possible in six others) and birth trauma (two) were probable causes. Specific conditions were found in six others. Only one infant (in nine evaluated) had an increased prothrombotic risk (fII mutation). In describing the lesions, we focused on the templates of infarction as seen in a parasagittal US sweep. Infarcts were confirmed by MRI in 21 patients. Our study showed that infarct topography can be evaluated reliably with brain sonography. This is important given the asymptomatic character of most lesions.

  18. Sen perforation af tyndtarm efter laparoskopisk gastrisk bypass

    DEFF Research Database (Denmark)

    Spanager, Lene; Sigild, Ulf Henrik; Neuenschwander, Anders Ulrich

    2010-01-01

    We present two cases in which the patients were admitted to a local hospital with acute abdominal pain four or five months after having undergone laparoscopic gastric bypass. In both cases, operation revealed a perforation of the small bowel close to the distal anastomosis. In the first case......, a massive constipation of the small bowel was most likely a contributing factor. In the second case, the cause was a kink of the entero-entero anastomosis leading to obstruction and finally perforation of the biliary limp. Late perforations are among the rarely reported complications associated with gastric...

  19. Equivalent Young's Modulus of Perforated Shell with Square Penetration Pattern

    Energy Technology Data Exchange (ETDEWEB)

    Jhung, Myung Jo; Ryu, Yong Ho [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2011-05-15

    The analysis of a plate or shell perforated with a large number of holes, by finite element method for instance, was a very costly and time-consuming technique which solves only one particular problem. But it is possible to model the perforated plate or shell and to analyze it and it is no more time-consuming theses days due to the rapid development of the computer and software. However, if a perforated plate or shell is submerged in fluid it is almost impossible to model and analyze it as is and the fluid at the same time, which is needed to investigate the effect of the fluid structure interaction. The simplest way to avoid time consuming and costly analysis of perforated plate or shell submerged in fluid is to replace the perforated plate or shell by an equivalent solid one considering weakening effect of holes. Many authors have proposed experimental or theoretical method to solve this problem for the plate. Slot and O'Donnell determined the effective elastic constants for the thick perforated plates by equating strains in the equivalent solid material to the average strains in the perforated material. O'Donnell also presented those of thin perforated plates. These results are implemented in Article A-8000 of Appendix A to the ASME code Section III, which contains a method of analysis for flat perforated plates when subjected to directly applied loads or loadings resulting from structural interaction with adjacent members. Unfortunately the effective elastic constants for the perforated shell are not found in any references. Therefore in this study the modal characteristics of the perforated shell are investigated and the equivalent material properties of perforated shell are suggested by performing several finite element analyses with respect to the ligament efficiencies

  20. Perforated pyloroduodenal peptic ulcer and sonography.

    Science.gov (United States)

    Kuzmich, Siarhei; Harvey, Chris J; Fascia, Daniel T M; Kuzmich, Tatsiana; Neriman, Deena; Basit, Rizwan; Tan, Kai Lee

    2012-11-01

    The purpose of this article is to illustrate the spectrum of sonographic findings in perforated pyloroduodenal peptic ulcer and discuss the potential role of sonography in the diagnosis. Although sonography is not the first-line investigation of choice in suspected perforated peptic ulcer, understanding of the characteristic appearances seen during general abdominal sonography may aid the reader in the diagnosis of this important and sometimes overlooked cause of nonspecific abdominal pain. This may shorten time to the diagnosis and ultimate surgical management.

  1. Spontaneous Uterine Perforation due to Pyometra Presenting as Acute Abdomen

    Directory of Open Access Journals (Sweden)

    Loabat Geranpayeh

    2006-01-01

    Full Text Available Spontaneous perforation of the uterus is rare, its incidence being about 0.01%–0.05%. We report a rare case of diffuse peritonitis caused by spontaneously perforated pyometra. A 63-year-old woman with severe abdominal pain was admitted to our hospital. Laparotomy was performed because of the suspicion of gastrointestinal perforation with generalized peritonitis. At laparotomy, about 900 mL of pus was found in the peritoneal cavity. There were no abnormal findings in the alimentary tract, liver, or gallbladder. A total abdominal hysterectomy with bilateral salpingo-oophorectomy was performed. Pathological investigation of the surgical specimen revealed endometritis and myometritis of the uterus; but there was no evidence of malignancy, and the cervical canal was patent. Although spontaneously perforated pyometra is rare, a perforated pyometra should therefore also be considered when elderly women present with acute abdominal pain.

  2. Risk of surgical glove perforation in oral and maxillofacial surgery.

    Science.gov (United States)

    Kuroyanagi, N; Nagao, T; Sakuma, H; Miyachi, H; Ochiai, S; Kimura, Y; Fukano, H; Shimozato, K

    2012-08-01

    Oral and maxillofacial surgery, which involves several sharp instruments and fixation materials, is consistently at a high risk for cross-contamination due to perforated gloves, but it is unclear how often such perforations occur. This study aimed to address this issue. The frequency of the perforation of surgical gloves (n=1436) in 150 oral and maxillofacial surgeries including orthognathic surgery (n=45) was assessed by the hydroinsufflation technique. Orthognathic surgery had the highest perforation rate in at least 1 glove in 1 operation (91.1%), followed by cleft lip and palate surgery (55.0%), excision of oral soft tumour (54.5%) and dental implantation (50.0%). The perforation rate in scrub nurses was 63.4%, followed by 44.4% in surgeons and first assistants, and 16.3% in second assistants. The odds ratio for the perforation rate in orthognathic surgery versus other surgeries was 16.0 (95% confidence interval: 5.3-48.0). The protection rate offered by double gloving in orthognathic surgery was 95.2%. These results suggest that, regardless of the surgical duration and blood loss in all fields of surgery, orthognathic surgery must be categorized in the highest risk group for glove perforation, following gynaecological and open lung surgery, due to the involvement of sharp objects. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Perforated peptic ulcer associated with abdominal compartment syndrome.

    Science.gov (United States)

    Lynn, Jiun-Jen; Weng, Yi-Ming; Weng, Chia-Sui

    2008-11-01

    Abdominal compartment syndrome (ACS) is defined as an increased intra-abdominal pressure with adverse physiologic consequences. Abdominal compartment syndrome caused by perforated peptic ulcer is rare owing to early diagnosis and management. Delayed recognition of perforated peptic ulcer with pneumoperitoneum, bowel distension, and decreased abdominal wall compliance can make up a vicious circle and lead to ACS. We report a case of perforated peptic ulcer associated with ACS. A 74-year-old man with old stroke and dementia history was found to have distended abdomen, edema of bilateral legs, and cyanosis. Laboratory tests revealed deterioration of liver and kidney function. Abdominal compartment syndrome was suspected, and image study was arranged to find the cause. The study showed pneumoperitoneum, contrast stasis in heart with decreased caliber of vessels below the abdominal aortic level, and diffuse lymphedema at the abdominal walls. Emergent laparotomy was performed. Perforated peptic ulcer was noted and the gastrorrhaphy was done. The symptoms, and liver and kidney function improved right after emergent operation.

  4. Flame treatment for the selective wetting and separation of PVC and PET.

    Science.gov (United States)

    Pascoe, R D; O'Connell, B

    2003-01-01

    Flame treatment has been used for many years to modify the surface of plastics to allow coatings to be added. The effect of the treatment is to produce hydrophilic species on the surface of the plastic making it water-wettable. The production of hydrophilic plastic surfaces is also required in the selective separation of plastics by froth flotation. For the process to be selective one plastic must be rendered hydrophilic while another remains hydrophobic. In this study the potential for separation of PVC and PET has been investigated. Flame treatment was shown to be very effective in producing a hydrophilic surface on both plastics, although the process was not selective under the conditions investigated. Raising the temperature of the plastics above their softening point produced a hydrophobic recovery. As the softening point of PVC was significantly lower than for PET it was possible to produce a significant difference in hydrophobicity, as judged using contact angle measurement. When immersed in water the contact angle of the PVC was found to be strongly dependent on the pH. Good separation efficiency of the two plastics was achieved by froth flotation from pH 4 to 9. One particular advantage of the technique is that no chemical reagents may be required in the flotation stage. The practicalities of designing a flake treatment system however have to be addressed before considering it to be a viable industrial process.

  5. Flame treatment for the selective wetting and separation of PVC and PET

    International Nuclear Information System (INIS)

    Pascoe, R.D.; O'Connell, B.

    2003-01-01

    Flame treatment has been used for many years to modify the surface of plastics to allow coatings to be added. The effect of the treatment is to produce hydrophilic species on the surface of the plastic making it water-wettable. The production of hydrophilic plastic surfaces is also required in the selective separation of plastics by froth flotation. For the process to be selective one plastic must be rendered hydrophilic while another remains hydrophobic. In this study the potential for separation of PVC and PET has been investigated. Flame treatment was shown to be very effective in producing a hydrophilic surface on both plastics, although the process was not selective under the conditions investigated. Raising the temperature of the plastics above their softening point produced a hydrophobic recovery. As the softening point of PVC was significantly lower than for PET it was possible to produce a significant difference in hydrophobicity, as judged using contact angle measurement. When immersed in water the contact angle of the PVC was found to be strongly dependent on the pH. Good separation efficiency of the two plastics was achieved by froth flotation from pH 4 to 9. One particular advantage of the technique is that no chemical reagents may be required in the flotation stage. The practicalities of designing a flake treatment system however have to be addressed before considering it to be a viable industrial process

  6. Infrared studies of PVC-based electrolytes incorporated with lithium triflate and 1-butyl-3-methyl imidazolium trifluoromethanesulfonate as ionic liquid

    Science.gov (United States)

    Zulkepeli, Nik A. S. Nik; Winie, Tan; Subban, R. H. Y.

    2017-09-01

    In this work, 1-butyl-3-methylimidazolium trifluoromethanesulfonate (BMIMCF3SO3) is employed as ionic liquid in PVC-based polymer electrolyte system with lithium triflate (LiCF3SO3) as doping salt. The samples in film form were prepared by quantitatively varying the concentration of BMIMCF3SO3 to a fixed ratio of PVC-LiCF3SO3 using solution cast technique. The highest room temperature ionic conductivity of 1.120 × 10-7 Scm-1 was exhibited by PVC-LiCF3SO3-BMIMCF3SO3 containing 3 wt. % BMIMCF3SO3. FTIR spectra of the polymer electrolytes were examined to study the complexation of the PVC-based polymer electrolytes. Intensity of free ions, ion pairs, and ion aggregates were obtained from FTIR deconvolution in an attempt to correlate with ionic conductivity results. The intensity of free ions was found to be high for sample with 3 wt. % BMIMCF3SO3.

  7. Perforated peptic ulcer in an infant.

    Science.gov (United States)

    Feng, C Y; Hsu, W M; Chen, Y

    2001-02-01

    We describe a case of perforated peptic ulcer (PPU) in a 9-month-old boy. Abdominal distension was the first clinical sign of PPU. Before he developed abdominal distension, the patient had suffered from an upper respiratory tract infection with fever for about 2 weeks, which was treated intermittently with ibuprofen. A plain abdominal radiograph revealed pneumoperitoneum with a football sign. At laparotomy, a 0.8-cm perforated hole was found over the prepyloric area. Simple closure with omental patching was performed after debridement of the perforation. Pathologic examination showed chronic peptic ulcer with Helicobacter pylori infection. The postoperative course and outcome were satisfactory. The stress of underlying disease, use of ibuprofen, blood type (A), and H. pylori infection might have contributed to the development of PPU in this patient. PPU in infancy is rare and has a high mortality rate; early recognition and prompt surgical intervention are key to successful management.

  8. A case report of esophageal perforation: Complication of nasogastric tube placement

    Science.gov (United States)

    Isik, Arda; Firat, Deniz; Peker, Kemal; Sayar, Ilyas; Idiz, Oguz; Soytürk, Mehmet

    2014-01-01

    Patient: Male, 70 Final Diagnosis: Esophageal perforation Symptoms: Abdominal pain • nausea • vomiting Medication: — Clinical Procedure: — Specialty: Surgery Objective: Unusual clinical course Background: Esophageal perforation is a well-defined and severe clinical condition. There are several etiologies of esophagus perforation. Case Report: We report the case of a 70-year-old Caucasian man who underwent an emergency cholecystectomy due to acute cholecystitis. Two days after surgery, his condition deteriorated. Thorax computerized tomography revealed an esophageal perforation. Conclusions: Esophageal perforation due to nasogastric application is relatively rare but the consequences are potentially serious. The anatomy of the upper gastrointestinal system should be understood by all healthcare professionals involved in the treatment. PMID:24803977

  9. Low-energy plasma-cathode electron gun with a perforated emission electrode

    Science.gov (United States)

    Burdovitsin, Victor; Kazakov, Andrey; Medovnik, Alexander; Oks, Efim; Tyunkov, Andrey

    2017-11-01

    We describe research of influence of the geometric parameters of perforated electrode on emission parameters of a plasma cathode electron gun generating continuous electron beams at gas pressure 5-6 Pa. It is shown, that the emission current increases with increasing the hole diameters and decreasing the thickness of the perforated emission electrode. Plasma-cathode gun with perforated electron can provide electron extraction with an efficiency of up to 72 %. It is shown, that the current-voltage characteristic of the electron gun with a perforated emission electrode differs from that of similar guns with fine mesh grid electrode. The plasma-cathode electron gun with perforated emission electrode is used for electron beam welding and sintering.

  10. Comparative study of three different kinds of geo membranes (PVC-P, HDPE, EPDM) used in the waterproofing of reservoirs; Estudio comparativo de tres geomembranas de distinta naturaleza (PVC-P, PEAD, EPDM) empleadas en la impermeabilizacion de balsas

    Energy Technology Data Exchange (ETDEWEB)

    Blanco Fernandez, M.; Castillo Rubi, F.; Soriano Carrillo, J.; Noval Arango, A. M.; Touze-Foltz, N.; Pargada Iglesias, L.; Rico Arnaiz, G.; Aguilar gonzalez, E.

    2014-02-01

    This work describes the long-term behaviour of three kinds of geo membranes which are constituted by plasticised poly vinyl chloride (PVC-P), high density polyethylene (HDPE) and terpolymer rubber of ethylene-propylene-dienic monomer (EPDM) used as the waterproofing system of the reservoirs Los Llanos de Mesa, San Isidro and El Golfo, respectively. Characteristics of the three original geo membranes and their behaviour along time are presented. Thicknesses, content and nature of the plasticizers ( in PVC-P), tensile properties dynamic and static puncture, fold ability at low temperature, shore hardness, tear resistance and carbon black ( in HDPE), joint strength (shear and peeling test) and microscopy, both optical and electronic scanning tests were carried out. Results obtained conclude with a long-term durability of geo membranes, independently of their macromolecular nature. These characteristics were determined by advanced analytical techniques in PVC-P samples, such as fourier Transform Infrared Spectroscopy (FTIR), Gas Chromatography (GC) and Mass Spectrometry (MS). Spectrometry (MS). (Author)

  11. Effect analysis of material properties of picosecond laser ablation for ABS/PVC

    Science.gov (United States)

    Tsai, Y. H.; Ho, C. Y.; Chiou, Y. J.

    2017-06-01

    This paper analytically investigates the picosecond laser ablation of ABS/PVC. Laser-pulsed ablation is a wellestablished tool for polymer. However the ablation mechanism of laser processing for polymer has not been thoroughly understood yet. This study utilized a thermal transport model to analyze the relationship between the ablation rate and laser fluences. This model considered the energy balance at the decomposition interface and Arrhenius law as the ablation mechanisms. The calculated variation of the ablation rate with the logarithm of the laser fluence agrees with the measured data. It is also validated in this work that the variation of the ablation rate with the logarithm of the laser fluence obeys Beer's law for low laser fluences. The effects of material properties and processing parameters on the ablation depth per pulse are also discussed for picosecond laser processing of ABS/PVC.

  12. HPFRCC - Extruded Pipes

    DEFF Research Database (Denmark)

    Stang, Henrik; Pedersen, Carsten

    1996-01-01

    The present paper gives an overview of the research onHigh Performance Fiber Reinforced Cementitious Composite -- HPFRCC --pipes recently carried out at Department of Structural Engineering, Technical University of Denmark. The project combines material development, processing technique development......-w$ relationship is presented. Structural development involved definition of a new type of semi-flexiblecement based pipe, i.e. a cement based pipe characterized by the fact that the soil-pipe interaction related to pipe deformation is an importantcontribution to the in-situ load carrying capacity of the pipe...

  13. Perforate on CHO cell membranes induced by electromagnetic ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-06-17

    Jun 17, 2009 ... Key words: Electromagnetic pulse (EMP), atomic force microscope, CHO cell, cell membrane. INTRODUCTION .... of perforation ranges from 390 to 660 nm and the depth is. 392.95 nm. ... cell membrane perforations increased when both the field intensity and ..... Melatonin and a spin-trap compound block.

  14. Perforated appendicitis: Risk factors and outcomes of management ...

    African Journals Online (AJOL)

    The case files of patients with perforated appendicitis were analysed in relation to age, sex, clinical presentation, management and outcome of management. The aim was to detect the main factors that contributed to the perforation of the appendix in these patients and assess the effectiveness of the treatment offered.

  15. Color Doppler Ultrasonography-Targeted Perforator Mapping and Angiosome-Based Flap Reconstruction

    DEFF Research Database (Denmark)

    Gunnarsson, Gudjon Leifur; Tei, Troels; Thomsen, Jørn Bo

    2016-01-01

    Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap reconstr......Knowledge about perforators and angiosomes has inspired new and innovative flap designs for reconstruction of defects throughout the body. The purpose of this article is to share our experience using color Doppler ultrasonography (CDU)-targeted perforator mapping and angiosome-based flap...

  16. Optimizing time management after perforation by colonoscopy results in better outcome for the patients.

    Science.gov (United States)

    Rumstadt, Bernhard; Schilling, Dieter

    2008-01-01

    Perforation during colonoscopy is a rare but severe complication. The aim of this study was to assess the time management and laparoscopic therapy of this complication and to evaluate patient outcomes. A retrospective analysis was done on 15 patients operated for a perforation from colonoscopy between January 2000 and December 2006. Three perforations occurred during diagnostic and 12 perforations during interventional colonoscopy. Two perforations occurred as transmural thermal injury to the colon wall. Peritonitis was found in 4 cases and significantly correlated with the mean time between perforation and operation. Twelve perforations were oversewn laparoscopically and 3 perforations were oversewn by laparotomy. After laparoscopic treatment, hospital stay was significantly shorter than after laparotomy. One patient had a postoperative wound infection, mortality was 0%. Laparoscopic oversewing is a safe and effective method in the treatment of perforation from colonoscopy. Optimizing the time range between perforation and laparoscopic therapy results in a better outcome for the patients.

  17. Pipe damping

    International Nuclear Information System (INIS)

    Ware, A.G.

    1985-01-01

    Studies are being conducted at the Idaho National Engineering Laboratory to determine whether an increase in the damping values used in seismic structural analyses of nuclear piping systems is justified. Increasing the allowable damping would allow fewer piping supports which could lead to safer, more reliable, and less costly piping systems. Test data from availble literature were examined to determine the important parameters contributing to piping system damping, and each was investigated in separate-effects tests. From the combined results a world pipe damping data bank was established and multiple regression analyses performed to assess the relative contributions of the various parameters. The program is being extended to determine damping applicable to higher frequency (33 to 100 Hz) fluid-induced loadings. The goals of the program are to establish a methodology for predicting piping system damping and to recommend revised guidelines for the damping values to be included in analyses

  18. Bladder perforations in children

    African Journals Online (AJOL)

    2014-11-20

    Nov 20, 2014 ... Mean recovery time for patients was 15 days. ... fracture.[1,2] Isolated bladder perforations are rare, and they .... PA, perineal injury, pelvic fracture. Trauma .... Lower genitourinary injury and pelvic fractures in pediatric patients.

  19. Traumatic oesophageal perforation due to haematoma

    DEFF Research Database (Denmark)

    Grønhøj Larsen, Christian; Brandt, Bodil

    2014-01-01

    . Three explanations postulated to be the cause for late perforation which might be due to esophageal wall ischemia from pressure built up between the hematoma, azygos vein and the lower part of thoracic trachea; or could be an immediate rupture walled-off until the patient became symptomatic......; or the intramural hematoma gradually lysed and causing late perforation. CONCLUSION: Although extremely rare, an oesophageal haematoma and late complications must be considered in patients on anti-coagulant therapy following blunt thoracic trauma and complaining only of chest pain....

  20. Pipe inspection using the pipe crawler. Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-05-01

    The US Department of Energy (DOE) continually seeks safer and more cost-effective remediation technologies for use in the decontamination and decommissioning (D and D) of nuclear facilities. In several of the buildings at the Fernald Site, there is piping that was used to transport process materials. As the demolition of these buildings occur, disposal of this piping has become a costly issue. Currently, all process piping is cut into ten-foot or less sections, the ends of the piping are wrapped and taped to prevent the release of any potential contaminants into the air, and the piping is placed in roll off boxes for eventual repackaging and shipment to the Nevada Test Site (NTS) for disposal. Alternatives that allow for the onsite disposal of process piping are greatly desired due to the potential for dramatic savings in current offsite disposal costs. No means is currently employed to allow for the adequate inspection of the interior of piping, and consequently, process piping has been assumed to be internally contaminated and thus routinely disposed of at NTS. The BTX-II system incorporates a high-resolution micro color camera with lightheads, cabling, a monitor, and a video recorder. The complete probe is capable of inspecting pipes with an internal diameter (ID) as small as 1.4 inches. By using readily interchangeable lightheads, the same system is capable of inspecting piping up to 24 inches in ID. The original development of the BTX system was for inspection of boiler tubes and small diameter pipes for build-up, pitting, and corrosion. However, the system is well suited for inspecting the interior of most types of piping and other small, confined areas. The report describes the technology, its performance, uses, cost, regulatory and policy issues, and lessons learned

  1. Pipe inspection using the pipe crawler. Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    The US Department of Energy (DOE) continually seeks safer and more cost-effective remediation technologies for use in the decontamination and decommissioning (D and D) of nuclear facilities. In several of the buildings at the Fernald Site, there is piping that was used to transport process materials. As the demolition of these buildings occur, disposal of this piping has become a costly issue. Currently, all process piping is cut into ten-foot or less sections, the ends of the piping are wrapped and taped to prevent the release of any potential contaminants into the air, and the piping is placed in roll off boxes for eventual repackaging and shipment to the Nevada Test Site (NTS) for disposal. Alternatives that allow for the onsite disposal of process piping are greatly desired due to the potential for dramatic savings in current offsite disposal costs. No means is currently employed to allow for the adequate inspection of the interior of piping, and consequently, process piping has been assumed to be internally contaminated and thus routinely disposed of at NTS. The BTX-II system incorporates a high-resolution micro color camera with lightheads, cabling, a monitor, and a video recorder. The complete probe is capable of inspecting pipes with an internal diameter (ID) as small as 1.4 inches. By using readily interchangeable lightheads, the same system is capable of inspecting piping up to 24 inches in ID. The original development of the BTX system was for inspection of boiler tubes and small diameter pipes for build-up, pitting, and corrosion. However, the system is well suited for inspecting the interior of most types of piping and other small, confined areas. The report describes the technology, its performance, uses, cost, regulatory and policy issues, and lessons learned.

  2. Perforation of the Esophagus Secondary to Insertion of Covered Wallstent Endoprostheses

    International Nuclear Information System (INIS)

    Farrugia, Mark; Morgan, Robert A.; Latham, Jennifer A.; Glynos, Michael; Mason, Robert C.; Adam, Andreas

    1997-01-01

    Perforation of the esophagus is a very rare complication of metallic esophageal stent insertion. Two cases are presented in which esophageal perforations were caused by the sharp ends of metallic stents impinging on the esophageal wall. In retrospect, both perforations might have been prevented by additional stent insertion

  3. THE STUDY OF TECHNOLOGICAL PROPERTIES OF PLASTISOLS BASED EMULSION PVC FILLED WITH CHALK GIDROFOBIZIROVANNYM

    Directory of Open Access Journals (Sweden)

    V. A. Sedykh

    2014-01-01

    Full Text Available Baby toys are made using the centrifugal molding plastisol based emulsion of polyvinyl chloride plasticized with dioctylphthalate. To reduce cost and decrease biotelemetry the dioctylphthalate on the surface of the product domestic toys than toys produced in China, there was a necessity of introduction of the filler is chalk from different manufacturers. By using a Brookfield vis-cometer PV-D was studied rheology of filled hydrophobized chalk PVC plastisols in storage conditions for up to 72 hours at temperatures of 14-20°C. It was found that the flow plastisols consistent with pseudo-plastic fluids. Given the flow rates of emulsion PVC plastisols filled to 35 % of the mass. hydrophobized chalk. The influence of the content of the plasticizer dioctylphthalate in a narrow interval (37,0 - 41,4 % of the mass. on the viscosity of polymer pastes and the kinetics of its changes during storage. Revealed a linear dependence of the viscosity of the filled hydrophobized chalk plastisols on the speed of rotation of the spindle of the viscometer and during storage. Given the rate of expansion changes the viscosity of the plastisols of the speed of rotation of the spindle of the viscometer, the rate of change in viscosity and calculation of the initial viscosity. Determined the stability of the dispersion hydrophobized chalk in a colloidal solution of PVC in dioctylphthalate during storage. We determined the variation of the content of chalk (ash with top and bottom layers plastisols height 8 cm after 24 hours storage. It is proved that the temperature of the preparation and storage of polymer pastes were determining factors in the regulation of such technological properties of PVC plastisols in the presence hydrophobized chalkas viscosity, stability of the dispersion of chalk and, consequently, the efficiency of distribution plastisols in the form of a centrifugal molding.

  4. Bending stresses: imposed on underground small diameter lines in city streets

    Energy Technology Data Exchange (ETDEWEB)

    Kottmann, A

    1975-05-01

    Die Technischen Werke der Stadt Stuttgart AG (TWS, Stuttgart) investigated the accuracy of available bending stress calculations to represent the actual stress exerted on underground pipelines, the effective bending intervals, and the pipe diameter required to effectively resist the expected stress. The investigation covers steel, cast iron, ductile cast iron, asbestos cement, and PVC 100. The theoretical stresses were determined by the Boussinesgne method from the effects of SLW60 vehicles on pipes buried 3.28 ft (1 m) underground. The cumulative load on the pipe was obtained as the total of the vehicle load, soil load, pipe load, and water load. Results indicate that the tensile stress from internal pipe pressure can be omitted, and that welded steel and sealed PVC pipes should account for longitudinal tensile stresses. Steel pipes are generally so oversized that they need not account for these stresses. The calculations also considered the interaction between the pipe and pipe joint as the pipe emerges from the trench for the 3 possible conditions: an overhang beam, a beam encased at one end and jointed at the other, and a beam, encased at both ends. The curves of the resisting moments varied according to the type of material and pipe diameter, with the greatest rate increase reported for asbestos cement, followed by PVC 100, cast iron, ductile cast iron, and steel. Operating data of a cast-iron underground TWS system in Stuttgart indicated that pipes with less than or equal to 4 in. ( less than or equal to 100 mm) nominal diameter were quite fragile while those with diameters >6 in. (>105 mm) sustained considerably less damage. The degree of damage was found to decrease with increasing diameters. The effect of temperature also proved important. Since it is not economically possible to reinstall the distribution lines with 8-in. (200-mm) pipes, elastic support systems such as crossing troughs are recommended to support the pipes in stress areas.

  5. The US findings of acute nonperforated and perforated appendicitis in children

    International Nuclear Information System (INIS)

    Bae, Jun Gi; Lee, Young Seok; Jung, Yoon Ho; Kim, Ji Hye; Lee, Woon Ki; Lee, Tae Hoon

    1996-01-01

    To analyse and interpret different sonographic findings in acute nonperforated and appendicitis. In 46 cases of acute appendicitis in children(26 girls, 20 boys) proven by surgery, sonographic findings were reviewed retrospectively. The findings of nonperforated and perforated appendicitis were analysed, focusing on the size, shape and echogenicity of the appendix, echo patterns of periappendiceal abscesses, mesenteric lymphadenopathy, and the prevalence of appendicolith. A noncompressible distended appendix was present in 18 of 21 patients with nonperforated appendicitis and in 13 of 25 patients with perforation. In 18 patients with nonperforated appendicitis, the average diameter of distended appendix was 8.6 mm ; target appearance was noted in 16 patients and loss of echogenic submucosa in two. In 13 patients with perforated appendicitis, the average diameter of appendix was 9.1 mm ; target appearance was noted in four patients and loss of echogenic submucosa in nine. Periappendiceal abscesses were present in 21 of 25 cases of perforated appendicitis, and the echogenicity of abscesses was mixed in 12 patients, hypoechogenic in eight, and hyperechogenic in one. Mesenteric lymphadenopathy was present in two of 21 patients with nonperforated appendicitis and in four of 25 with perforation. Appendicolith was detected on sonography in three of 25 patients with perforated appendicitis, but was found in seven patients during surgery. One patients with perforated appendicitis also had right side hydronephrosis. Sonographically false-negative results were obtained in six cases. A sonographic examination was useful to differenciate perforated and nonperforated appendicitis in children. Loss of echogenic submucosa in the distended appendix and periappendiceal abscess formation were important findings in diagnosis of perforated appendicitis

  6. Esophageal perforation during or after conformal radiotherapy for esophageal carcinoma

    International Nuclear Information System (INIS)

    Chen Haiyan; Ma Xiumei; Ye Ming; Hou Yanli; Xie Huaying; Bai Yongrui

    2014-01-01

    The aim of this study was to analyze the risk factors and prognosis for patients with esophageal perforation occurring during or after radiotherapy for esophageal carcinoma. We retrospectively analyzed 322 patients with esophageal carcinoma. These patients received radiotherapy for unresectable esophageal tumors, residual tumors after operation, or local recurrence. Of these, 12 had radiotherapy to the esophagus before being admitted, 68 patients had concurrent chemoradiotherapy (CRT), and 18 patients had esophageal perforation after RT (5.8%). Covered self-expandable metallic stents were placed in 11 patients. Two patients continued RT after stenting and control of infection; one of these suffered a new perforation, and the other had a massive hemorrhage. The median overall survival was 2 months (0-3 months) compared with 17 months in the non-perforation group. In univariate analysis, the Karnofsky performance status (KPS) being ≤ 70, age younger than 60, T4 stage, a second course of radiotherapy to the esophagus, extracapsular lymph nodes (LN) involving the esophagus, a total dose > 100 Gy (biologically effective dose -10 ), and CRT were risk factors for perforation. In multivariate analysis, age younger than 60, extracapsular LN involving the esophagus, T4 stage, and a second course of radiotherapy to the esophagus were risk factors. In conclusion, patients with T4 stage, extracapsular LN involving the esophagus, and those receiving a second course of RT should be given particular care to avoid perforation. The prognosis after perforation was poor. (author)

  7. A CLINICAL STUDY ON PATIENTS WITH DUODENAL ULCER PERFORATION

    Directory of Open Access Journals (Sweden)

    Kishore Babu

    2016-03-01

    Full Text Available INTRODUCTION Perforated duodenal ulcer, the most catastrophic complication was Associated with high mortality in the past due to late presentation of the patients, delay in surgery and lack of antibiotics. Various authors state that the incidence of peptic ulcer disease and perforation has been declining for the past 3 decades. Because of advances in the medical therapy of peptic ulcer with a wide range of drugs the management of peptic ulcer disease has been changing and the role of surgery has been declining. Perforation is usually seen in 3rd and 4th decades with a male preponderance and the epidemiological trend is not the same worldwide. Incidence is slightly declining in western countries. The present study has been done during the period between 2013 and 2014 in S. V. R. R. Government general hospital Tirupati. AIMS AND OBJECTIVES The aim of the present study is to analyze the probable factors for increase in incidence of duodenal ulcer perforation, with particular emphasis on assessment of impact of H2 receptor antagonists and Proton Pump inhibitors on the incidence of perforation. STUDY SETTING S. V. Medical College, Department of General Surgery, Tirupati. STUDY PERIOD Patients attending S. V. Medical College, Department of General Surgery with perforation during the period from November 2013 to October 2014. INCLUSION CRITERIA Patients between age group of more than 14 years presenting with pain abdomen and who are diagnosed to have peritonitis due to duodenal ulcer perforation. EXCLUSION CRITERIA Patients with peritonitis due causes other than duodenal ulcer. STUDY METHOD Prospective Observational study among the selected patients. Total numbers of peptic ulcer cases that were admitted in this hospital and treated either medically or surgically were noted. The details of their clinical history and findings, investigation reports, operative findings, post-operative complications were recorded. Simple closure was performed for all the

  8. Jejunal perforation by swallowed ibuprofen caplet | Njoku | Nigerian ...

    African Journals Online (AJOL)

    We present a case of jejunal perforation caused by an unusual foreign body, an ibuprofen caplet in its blister packing believed to be the first of its kind, perforation of the intestine caused by an ingested medication. The patient eventually developed an enterocutaneous fistula through the weak wall of a preexisting incisional ...

  9. Effects of silica composition on gas permeability of ENR/PVC ...

    African Journals Online (AJOL)

    At higher SiO2 loadings, the mechanical strength of the membrane decreased due to the agglomeration of SiO2 particles. Gas permeation test was done on ENR/PVC/SiO2 membranes using NO2 gas and CO2 gas. The permeability of both gasses increased with the amount of SiO2 added to the membrane, which attributed ...

  10. Migration from PVC cling films compared with their field of application

    DEFF Research Database (Denmark)

    Petersen, Jens Højslev; Lillemark, L.; Lund, L.

    1997-01-01

    Samples of PVC cling films were taken at importers, wholesalers and retail shops, and their overall migration to the alternative food simulant iso-octane was measured, after establishment of a correlation between overall migration to olive oil at 40 degrees C in 10 days and to iso-octane in 2 h...

  11. Mechanical properties of oil palm empty fruit bunch (OPEFB) fiber reinforced PVC/ENR blend

    International Nuclear Information System (INIS)

    Gunasunderi Raju Nor Azowa Ibrahim; Mohammad Zaki Abd Rahman; Wan Md Zin Wan Yunus; Chantara Thevy Ratnam

    2004-01-01

    The effect of OPEFB fiber on the mechanical properties of the 50/50 PVC/ENR was investigated over a range of fiber loadings (0 to 30%). The OPEFB fiber reinforced PVC/ENR blend was prepared by using Haake Rheomixer at 150 degree C mixing temperature, 20 minutes total mixing time and 50 rpm rotor speed. The changes in tensile strength (Ts), Young's modulus, elongation break (Eb), flexural modulus, hardness and impact strength with the OPEFB fiber loadings were investigated. The results revealed that the flexural modulus, Young's modulus and hardness increased with the fiber loading. However, the impact strength, Ts and Eb found to decrease with the increase in fiber loading. (Author)

  12. PVC membrane based potentiometric sensor for uranyl ion using thenoyl trifluoro acetone as ionophore

    International Nuclear Information System (INIS)

    Nanda, D.; Chouhan, H.P.S.; Maiti, B.

    2004-01-01

    Uranyl ion selective electrode based on thenoyl trifluoro acetone (TTA) incorporated into a polyvinyl chloride (PVC) membrane has been developed where dibutyl phthalate and sodium tetraphenyl borate have been used as plasticizer and anion excluder respectively. The PVC membrane containing the active ionophore, TTA, and the other ingredients has been directly cast a graphite electrode. The electrode shows near Nernstian response to UO 2 2+ in the concentration range of 10 -1 to 10 -6 mol. L -1 an average slope of 30 mV/decade. Alkali and alkaline earth ions do not interfere with the determination of uranyl ion. Interference of transition metal ions and Th (IV) is eliminated using EDTA. (author)

  13. Cause rare d'une perforation de la cloison nasale

    Science.gov (United States)

    Jahidi, Ali; Hemmaoui, Bouchaïb; Itoua, Wulfran Rosaire; Errami, Noureddine; Benariba, Fouad

    2014-01-01

    Les perforations de la cloison nasale constituent une pathologie fréquente en ORL. Leurs causes sont multiples et restent dominées par les traumatismes chirurgicaux. Les étiologies infectieuses et notamment la tuberculose sont rares. Nous présentons le cas d'une patiente ayant bénéficié d'une méatotomie bilatérale et chez laquelle une perforation de la cloison nasale a été découverte lors d'un examen systématique à un an de son intervention. D'abord considérée comme une complication de la chirurgie, la biopsie des berges de la perforation a permis de déterminer son origine tuberculeuse. La présentation clinique des perforations de la cloison nasale n'est pas spécifique. Elles sont souvent asymptomatiques et de découverte fortuite. Les traumatismes notamment chirurgicaux sont le plus siuvent en cause. L′orogine tuberculeuse resta très rare. Le diagnostic de certitude de tuberculose repose sur la biopsie des berges de cette perforation. Le but de ce travail est de mettre en avant l'intérêt de la biopsie dans le diagnostic de la tuberculose de la cloison nasale. Cette biopsie doit être systématique même en cas d'antécédents de chirurgie endonasale qui est le plus souvent en cause dans les perforations de la cloison nasale. PMID:24932334

  14. Reconstruction of pressure sores with perforator-based propeller flaps.

    Science.gov (United States)

    Jakubietz, Rafael G; Jakubietz, Danni F; Zahn, Robert; Schmidt, Karsten; Meffert, Rainer H; Jakubietz, Michael G

    2011-03-01

    Perforator flaps have been successfully used for reconstruction of pressure sores. Although V-Y advancement flaps approximate debrided wound edges, perforator-based propeller flaps allow rotation of healthy tissue into the defect. Perforator-based propeller flaps were planned in 13 patients. Seven pressure sores were over the sacrum, five over the ischial tuberosity, and one on the tip of the scapula. Three patients were paraplegic, six were bedridden, and five were ambulatory. In three patients, no perforators were found. In 10 patients, propeller flaps were transferred. In two patients, total flap necrosis occurred, which was reconstructed with local advancement flaps. In two cases, a wound dehiscence occurred and had to be revised. One hematoma required evacuation. No further complications were noted. No recurrence at the flap site occurred. Local perforator flaps allow closure of pressure sores without harvesting muscle. The propeller version has the added benefit of transferring tissue from a distant site, avoiding reapproximation of original wound edges. Twisting of the pedicle may cause torsion and venous obstruction. This can be avoided by dissecting a pedicle of at least 3 cm. Propeller flaps are a safe option for soft tissue reconstruction of pressure sores. © Thieme Medical Publishers.

  15. Hotspots for selected metal elements and microbes accumulation and the corresponding water quality deterioration potential in an unchlorinated drinking water distribution system.

    Science.gov (United States)

    Liu, Gang; Tao, Yu; Zhang, Ya; Lut, Maarten; Knibbe, Willem-Jan; van der Wielen, Paul; Liu, Wentso; Medema, Gertjan; van der Meer, Walter

    2017-11-01

    Biofilm formation, loose deposit accumulation and water quality deterioration in drinking water distribution systems have been widely reported. However, the accumulation and distribution of harbored elements and microbes in the different niches (loose deposits, PVC-U biofilm, and HDPE biofilm) and their corresponding potential contribution to water quality deterioration remain unknown. This precludes an in-depth understanding of water quality deterioration and the development of proactive management strategies. The present study quantitatively evaluated the distribution of elements, ATP, Aeromonas spp., and bacterial communities in distribution pipes (PVC-U, D = 110 mm, loose deposit and biofilm niches) and household connection pipes (HDPE, D = 32 mm, HDPE biofilm niches) at ten locations in an unchlorinated distribution system. The results show that loose deposits in PVC-U pipes, acting as sinks, constitute a hotspot (highest total amount per meter pipe) for elements, ATP, and target bacteria groups (e.g., Aeromonas spp., Mycobacterium spp., and Legionella spp.). When drinking water distribution system niches with harbored elements and microbes become sources in the event of disturbances, the highest quality deterioration potential (QDP) is that of HDPE biofilm; this can be attributed to its high surface-to-volume ratio. 16s rRNA analysis demonstrates that, at the genus level, the bacterial communities in the water, loose deposits, PVC-U biofilm, and HDPE biofilm were dominated, respectively, by Polaromonas spp. (2-23%), Nitrosipra spp. (1-47%), Flavobacterium spp. (1-36%), and Flavobacterium spp. (5-67%). The combined results of elemental composition and bacterial community analyses indicate that different dominant bio-chemical processes might occur within the different niches-for example, iron-arsenic oxidizing in loose deposits, bio-calumniation in PVC-U biofilm, and methane oxidizing in HDPE biofilm. The release of 20% loose deposits, 20% PVC-U biofilm

  16. Small bowel perforation due to fish bone: A case report

    Directory of Open Access Journals (Sweden)

    Huseyin Pulat

    2015-09-01

    Full Text Available Accidental ingestion of foreign bodies are a common condition in clinical practice. However, small bowel perforation which dues to ingestion foreign bodies has been rarely seen. In this article, we report a case of small bowel perforation which dues to ingestion foreign body. A 80-year-old female patient, presenting with complaints of acute abdomen, was admitted to the emergency department. She denied abdominal pain, nausea and vomiting. The patient had tenderness and defense on the right lower quadrant. Contrast enhanced abdominal computed tomography has been used on the patient's diagnosis. This revealed small bowel perforation due to the ingestion of foreign body. The patient was operated emergency. A microperforation due to fish bone was detected on the terminal ileum. The patient underwent debridement and primary repair. The patient was discharged postoperative 7th day without problem. Bowel perforation due to the ingestion of foreign bodies should be considered in the differential diagnosis of acute abdomen. Keywords: Foreign body, Small intestine, Perforation

  17. Pipe connector

    International Nuclear Information System (INIS)

    Sullivan, T.E.; Pardini, J.A.

    1978-01-01

    A safety test facility for testing sodium-cooled nuclear reactor components includes a reactor vessel and a heat exchanger submerged in sodium in the tank. The reactor vessel and heat exchanger are connected by an expansion/deflection pipe coupling comprising a pair of coaxially and slidably engaged tubular elements having radially enlarged opposed end portions of which at least a part is of spherical contour adapted to engage conical sockets in the ends of pipes leading out of the reactor vessel and in to the heat exchanger. A spring surrounding the pipe coupling urges the end portions apart and into engagement with the spherical sockets. Since the pipe coupling is submerged in liquid a limited amount of leakage of sodium from the pipe can be tolerated

  18. Monitoring underground water leakage pattern by ground penetrating radar (GPR) using 800 MHz antenna frequency

    Science.gov (United States)

    Amran, T. S. T.; Ismail, M. P.; Ahmad, M. R.; Amin, M. S. M.; Ismail, M. A.; Sani, S.; Masenwat, N. A.; Basri, N. S. M.

    2018-01-01

    Water is the most treasure natural resources, however, a huge amount of water are lost during its distribution that leads to water leakage problem. The leaks meant the waste of money and created more economic loss to treat and fix the damaged pipe. Researchers and engineers have put tremendous attempts and effort, to solve the water leakage problem especially in water leakage of buried pipeline. An advanced technology of ground penetrating radar (GPR) has been established as one of the non-destructive testing (NDT) method to detect the underground water pipe leaking. This paper focuses on the ability of GPR in water utility field especially on detection of water leaks in the underground pipeline distribution. A series of laboratory experiments were carried out using 800-MHz antenna, where the performance of GPR on detecting underground pipeline and locating water leakage was investigated and validated. A prototype to recreate water-leaking system was constructed using a 4-inch PVC pipe. Different diameter of holes, i.e. ¼ inch, ½ inch, and ¾ inch, were drilled into the pipe to simulate the water leaking. The PVC pipe was buried at the depth of 60 cm into the test bed that was filled with dry sand. 15 litres of water was injected into the PVC pipe. The water leakage patterns in term of radargram data were gathered. The effectiveness of the GPR in locating the underground water leakage was ascertained, after the results were collected and verified.

  19. Oil palm empty fruit bunch (OPEFB) fiber reinforced PVC/ENR blend-electron beam irradiation

    International Nuclear Information System (INIS)

    Ratnam, Chantara Thevy; Raju, Gunasunderi; Wan Md Zin Wan Yunus

    2007-01-01

    The effect of irradiation on the tensile properties of oil palm empty fruit bunch (OPEFB) fiber reinforced poly(vinyl chloride)/epoxidized natural rubber (PVC/ENR) blends were studied. The composites were prepared by mixing the fiber and the PVC/ENR blend using HAAKE Rheomixer at 150 deg. C. The composites were then irradiated by using a 3.0 MeV electron beam machine at doses ranging from 0 to 100 kGy in air and room temperature. The tensile strength, Young's modulus, elongation at break and gel fraction of the composites were measured. Comparative studies were also made by using poly(methyl acrylate) grafted OPEFB fiber in the similar blend system. An increase in tensile strength, Young's modulus and gel fraction, with a concurrent reduction in the elongation at break (Eb) of the PVC/ENR/OPEFB composites were observed upon electron beam irradiation. Studies revealed that grafting of the OPEFB fiber with methyl acrylate did not cause appreciable effect to the tensile properties and gel fraction of the composites upon irradiation. The morphology of fractured surfaces of the composites, examined by a scanning electron microscope showed an improvement in the adhesion between the fiber and the matrix was achieved upon grafting of the fiber with methyl acrylate

  20. Perforated Duodenal Ulcer in a Young Child: An Uncommon Condition

    Directory of Open Access Journals (Sweden)

    Rohit Prasad Yadav

    2009-04-01

    Full Text Available Duodenal ulcer is an uncommonly diagnosed entity in children. H. pyloriinfection, blood group ‘O’ or secondary to medications like non steroidal anti-infl ammatory drugs (NSAID and corticosteroids or physiological stress in burns, head injury and mucosal ischemia are implicated as risk factors for their causation. The diagnosis is usually overlooked because of vague and variable symptoms and remote index of suspicion accounted for their low incidence in children. Undiagnosed or mistreated perforations may carry high morbidity and mortality. We report a successfully treated 41/2 year old male child who presented with features of perforation peritonitis and was incidentally found to have a perforated duodenal ulcer. Key Words: duodenal ulcer, laparotomy, perforation

  1. Utilization of Agrowaste Polymers in PVC/NBR Alloys: Tensile, Thermal, and Morphological Properties

    Directory of Open Access Journals (Sweden)

    Ahmad Mousa

    2012-01-01

    Full Text Available Poly(vinyl chloride/nitrile butadiene rubber (PVC/NBR alloys were melt-mixed using a Brabender Plasticorder at 180∘C and 50 rpm rotor speed. Alloys obtained by melt mixing from PVC and NBR were formulated with wood-flour- (WF- based olive residue, a natural byproduct from olive oil extraction industry. WF was progressively increased from 0 to 30 phr. The effects of WF loadings on the tensile properties of the fabricated samples were inspected. The torque rheometry, which is an indirect indication of the melt strength, is reported. The pattern of water uptake for the composites was checked as a function WF loading. The fracture mode and the quality of bonding of the alloy with and without filler are studied using electron scanning microscope (SEM.

  2. Perforated choledochal cyst in a Jehovah's Witness patient.

    Science.gov (United States)

    Jones, V S; Philip, C

    2007-07-01

    Perforation is a rare presentation of a choledochal cyst. The case reported is a 9-month-old female baby with a perforated choledochal cyst. Being a Jehovah's Witness, blood tranfusion was refused. Apart from highlighting this social dilemma, the suitability of a cystojejunostomy as a temporary measure in the above scenario is evaluated and discussed.

  3. Tubo de PVC liso com diferentes envoltórios como material alternativo na drenagem subterrânea Smooth PVC tube with different envelopes as an alternative material in the subsurface drainage

    Directory of Open Access Journals (Sweden)

    Florício P. de Almeida

    2003-04-01

    Full Text Available Em regiões áridas e semi-áridas irrigadas a drenagem é, freqüentemente, necessária para prevenir o encharcamento do solo e o controle da salinidade. Um dos principais obstáculos na instalação de um sistema de drenagem subterrânea é o alto custo do investimento inicial. Assim, alguma contribuição que reduza o custo da instalação dos drenos e também do material usado, é altamente vantajosa. Diante disso, o objetivo desta pesquisa foi avaliar, em condições de laboratório, o desempenho hidráulico do sistema drenante constituído pelo tubo de PVC liso, próprio para esgoto doméstico, de 50,0 mm de diâmetro nominal e área aberta de 23,0 cm² m-1, e por três tipos de envoltório. O desempenho do tubo drenante de PVC liso demonstrou que esse material é tecnicamente viável para drenagem agrícola, principalmente com o uso de brita como envoltório.In irrigated arid and semi-arid regions the drainage is, frequently, necessary to prevent the waterlogging of the soil and to control the salinity. One of the main obstacles in the installation of a subsurface drainage system is the high cost of the initial investment. Thus, some contribution that reduces the cost of the installation of the drains and also of the material used is highly advantageous. The objective of this research was to evaluate, under laboratory conditions, the hydraulic performance of the drainage system constituted by smooth PVC tube used for sewer with 50.0 mm of nominal diameter and open area of 23.0 cm² m-1 and different types of envelopes, as an alternative material for subsurface drainage. The performance of the smooth PVC tube demonstrated that this material is technically viable for agricultural drainage principally when used with single stones as envelope.

  4. Gastric Perforation by Ingested Rabbit Bone Fragment

    Directory of Open Access Journals (Sweden)

    Giulio Gambaracci

    2016-04-01

    Full Text Available The majority of accidentally ingested foreign bodies is excreted from the gastrointestinal (GI tract without any complications. Sometimes sharp foreign bodies – like chicken and fish bones – can lead to intestinal perforation and may present insidiously with a wide range of symptoms and, consequently, different diagnoses. We report the case of a 59-year-old woman presenting with fever and a 1-month history of vague abdominal pain. Computed tomography (CT showed the presence of a hyperdense linear image close to the gastric antrum surrounded by a fluid collection and free peritoneal air. At laparotomy, a 4-cm rabbit bone fragment covered in inflamed tissue was detected next to a gastric wall perforation. Rabbit bone fragment ingestion, even if rarely reported, should not be underestimated as a possible cause of GI tract perforation.

  5. A rare manifestation of perforated diverticulitis: parastomal subcutaneous abscess.

    NARCIS (Netherlands)

    Peters, J.H.; Bleichrodt, R.P.; Goor, H. van

    2003-01-01

    Perforation is a serious complication of diverticular disease. The sigmoid is the main affected anatomic site of perforated diverticulitis and sigmoid resection followed either by Hartmann procedure or primary anastomosis are the standard surgical approaches. Surgery, however, does not cure

  6. Study on modal characteristics of perforated shell using effective Young's modulus

    International Nuclear Information System (INIS)

    Jhung, Myung Jo; Yu, Seon Oh

    2011-01-01

    Research highlights: → The effective Young's modulus of perforated shell is proposed for modal analysis. → The penetration pattern is almost negligible for effective elastic constants. → The frequency of perforated shell decreases significantly due to the hole effect. - Abstract: For the perforated cylindrical shell submerged in fluid, it is almost impossible to develop a finite element model due to the necessity of the fine meshing of the shell and the fluid at the same time. This necessitates the use of solid shell with effective material properties. Unfortunately the effective elastic constants are not found in any references even though the ASME code is suggesting those for perforated plate. Therefore in this study the effective material properties of perforated shell are suggested by performing several finite element analyses with respect to the ligament efficiencies.

  7. Delayed Diagnosis of Pharyngeal Perforation following Exploding Tyre Blast Barotrauma

    Directory of Open Access Journals (Sweden)

    Samantha M. Field

    2014-01-01

    Full Text Available Introduction. Pharyngoesophageal perforation secondary to barotrauma is a rare phenomenon that can have serious complications if identified late. It is challenging to detect due to nonspecific symptoms. We present a case in which detection proved difficult leading to delayed diagnosis. Case Report. A 27-year-old mechanic presented with haemoptysis, dysphonia, and odynophagia after a car tyre exploded in his face. Flexible nasoendoscopy (FNE revealed blood in the pharynx, thought to represent mucosal haemorrhage. Initial treatment consisted of IV dexamethasone and antibiotics. After 3 days, odynophagia persisted prompting a CT scan. This revealed a defect in the posterior hypopharynx and surgical emphysema in the deep neck tissues. Contrast swallow confirmed posterior hypopharyngeal leak. NG feeding was commenced until repeated contrast swallow confirmed resolution of the defect. Discussion. Prompt nonsurgical management of pharyngoesophageal perforation has good outcomes but untreated perforation can have serious complications. FNE should be performed routinely, but only a contrast swallow can diagnose a functional perforation. Clinicians should have a high index of clinical suspicion when patients present with barotrauma and odynophagia. Patients should be kept nil by mouth until perforation has been excluded. Conclusion. When faced with cases of facial barotrauma, clinicians should have a low threshold for further imaging to exclude pharyngoesophageal perforation.

  8. Laparoscopic lavage for perforated diverticulitis with purulent peritonitis

    DEFF Research Database (Denmark)

    Thornell, Anders; Angenete, Eva; Bisgaard, Thue

    2016-01-01

    Background: Perforated diverticulitis with purulent peritonitis has traditionally been treated with open colon resection and stoma formation with risk for reoperations, morbidity, and mortality. Laparoscopic lavage alone has been suggested as definitive treatment. Objective: To compare laparoscopic...... lavage with open colon resection and colostomy (Hartmann procedure) for perforated diverticulitis with purulent peritonitis. Design: Randomized, controlled, multicenter, open-label trial. (ISRCTN registry number: ISRCTN82208287) Setting: 9 hospitals in Sweden and Denmark. Patients: Patients who have...... confirmed Hinchey grade III perforated diverticulitis with purulent peritonitis at diagnostic laparoscopy. Intervention: Randomization between laparoscopic lavage and the Hartmann procedure. Measurements: Primary outcome was the percentage of patients having 1 or more reoperations within 12 months. Key...

  9. Some considerations on the utilization of thermal drainage for greenhouse heating by means of indirect heat exchange system

    International Nuclear Information System (INIS)

    Yamamoto, Yujiro; Aoki, Kiyoshi; Okano, Toshiaki

    1976-01-01

    The cost of maintaining the desirable temperature in winter is the principal element in the production of vegetables by greenhouse culture. Therefore very low heating cost and profitable operation are possible if the warm water from a condenser in a power plant is available as the heat source for greenhouse heating. In order to investigate the possibility of utilizing warm water discharge as the heat source for greenhouse heating, experiment was carried out with a miniature greenhouse equipped with the indirect heat exchanger with PVC pipes. The results obtained are summarized as follows. Under the conditions of the warm water discharge of 25 deg C and outside air temperature of -5 deg C, the average temperature and relative humidity in the greenhouse were about 10 deg C and 80%, respectively. From the experimentally obtained relationship between the heat transfer coefficient on the PVC pipe surfaces and the velocity of air passing through the pipes, the heat transfer coefficient at 8 m/sec air velocity was three times as much as that at 2 m/sec. From the theoretically obtained formula for calculating the number of pipes required for a greenhouse, it was determined that 72 PVC pipes of 10 cm diameter and 23 m long were required for a 23 x 25 m greenhouse to maintain 12 deg C inside under the before-described conditions. (Kako, I.)

  10. Transmural coil embolization—alternative technique for management of arterial perforation during subintimal angioplasty

    Directory of Open Access Journals (Sweden)

    Karthikeyan Damodharan

    2016-01-01

    Full Text Available Subintimal angioplasty of lower limb arterial occlusion carries a relatively higher risk of vessel perforation compared to transluminal angioplasty. Vessel perforation is a potentially life threatening complication which requires prompt recognition and management. They are usually managed by endovascular techniques such as low-pressure balloon tamponade, covered stents, and coil embolization of the ruptured artery. We describe a technique of treating vessel perforation following balloon angioplasty. Patient developed a large perforation of the proximal superficial femoral artery (SFA after balloon inflation during subintimal angioplasty of complete SFA occlusion. Following failure of balloon tamponade in sealing the perforation, we successfully treated it by deploying an embolization coil at the site of perforation through the vessel wall followed by balloon tamponade. Our technique could be a useful relatively inexpensive alternative treatment option in the management of vessel perforation compared to covered stents.

  11. External perforated Solar Screens for daylighting in residential desert buildings: Identification of minimum perforation percentages

    KAUST Repository

    Sherif, Ahmed

    2012-06-01

    The desert climate is endowed by clear sky conditions, providing an excellent opportunity for optimum utilization of natural light in daylighting building indoor spaces. However, the sunny conditions of the desert skies, in countries like Egypt and Saudi Arabia, result in the admittance of direct solar radiation, which leads to thermal discomfort and the incidence of undesired glare. One type of shading systems that is used to permit daylight while controlling solar penetration is " Solar Screens" Very little research work addressed different design aspects of external Solar Screens and their influence on daylighting performance, especially in desert conditions, although these screens proved their effectiveness in controlling solar radiation in traditional buildings throughout history.This paper reports on the outcomes of an investigation that studied the influence of perforation percentage of Solar Screens on daylighting performance in a typical residential living room of a building in a desert location. The objective was to identify minimum perforation percentage of screen openings that provides adequate illuminance levels in design-specific cases and all-year-round.Research work was divided into three stages. Stage one focused on the analysis of daylighting illuminance levels in specific dates and times, while the second stage was built on the results of the first stage, and addressed year round performance using Dynamic Daylight Performance Metrics (DDPMs). The third stage addressed the possibility of incidence of glare in specific cases where illuminance levels where found very high in some specific points during the analysis of first stage. The research examined the daylighting performance in an indoor space with a number of assumed fixed experimentation parameters that were chosen to represent the principal features of a typical residential living room located in a desert environment setting.Stage one experiments demonstrated that the screens fulfilled the

  12. Spectrum of perforation peritonitis in Pakistan: 300 cases Eastern experience

    OpenAIRE

    Ur-Rahman Shafiq; Malik Faiza; Afridi Shahida; Shamim Shahid; Samo Khursheed A

    2008-01-01

    Abstract Background Perforation peritonitis is the most common surgical emergency encountered by the surgeons all over the world as well in Pakistan. The spectrum of etiology of perforation peritonitis in tropical countries continues to differ from its western counter part. This study was conducted at Dow University of health sciences and Civil Hospital Karachi (DUHS & CHK) Pakistan, designed to highlight the spectrum of perforation peritonitis in the East and to improve its outcome. Methods ...

  13. CLINICAL STUDY OF APPENDICULAR PERFORATION IN A TERTIARY CARE HOSPITAL

    Directory of Open Access Journals (Sweden)

    Venkata Anantha Lakshmi Manabala

    2016-06-01

    Full Text Available INTRODUCTION Acute Appendicitis is the commonest abdominal surgical emergency in young adults all over the world. In early 1900s, Ochsner in Chicago and Sherren at the London Hospital were both advocates of conservative treatment in late cases. Appendicular perforation is a serious complication in view of the ensuing peritonitis with the consequent sequelae and morbidity. AIM To study the incidence, morbidity and sequelae of appendicular perforation. MATERIALS & METHODS This is a prospective study done in our hospital where 110 cases of peritonitis due to appendicular perforation were selected for our study. All the cases where peritonitis was due to appendicular perforation at laparotomy were included. The study period was from January 2014 to December 2015. The cases of peritonitis due to other causes like duodenal, gastric, enteric perforation were excluded. Patients with acute abdominal emergency with clinical diagnosis of peritonitis were examined carefully with detailed history and clinical examination. Necessary investigations were done and patients taken up for emergency surgery. CONCLUSIONS Acute Appendicitis is the commonest abdominal surgical emergency in young adults all over the world. Age incidence of appendicular perforation is maximum in the age group of 21–30 years. Next common age group is 31–40 yrs. Incidence is more in males. Male to female ratio is 2.4:1. Pain abdomen, vomiting, fever and anorexia were common symptoms in all the patients. Majority of the patients came late to the hospital accounting for the cause of perforation and subsequent mortality and morbidity.

  14. Deterioration of plasticized PVC components in Apollo spacesuits

    DEFF Research Database (Denmark)

    Shashoua, Yvonne; Schnell, Ulrich; Young, Lisa

    2002-01-01

    Spacesuits from the Apollo era are unique in their history, materials and construction. This project involved the first detailed examination of the condition of the spacesuits since their acquisition by the National Air and Space Museum in the 1970s. Plasticized polyvinyl chloride (PVC) tubing...... in the Life Support System, used to transport air and water to the astronaut, and in the Liquid Cooling Garment, used to cool the wearer of the spacesuit, exhibited high levels of deterioration. Tubing was unacceptably discoloured, tacky to the touch and surfaces were obscured by crystals. Visual examination...

  15. The research progress of acute small bowel perforation

    Directory of Open Access Journals (Sweden)

    Rudolf Schiessel

    2015-08-01

    Full Text Available This article reviews the various aetiologies of small bowel perforations and their management. In addition to the well-known aetiologies such as trauma, inflammation and circulatory disorders, several new causes of small bowel perforation have been described in recent years. The spectrum reaches from iatrogenic perforations during laparoscopic surgery or enteroscopies to drug-induced perforations with new anticancer agents. The management of small bowel perforations requires a concept consisting of the safe revision of the leaking bowel and the treatment of the peritonitis. Depending on the local situation and the condition of the patient, several treatment options are available. The surgical management of the bowel leak can range from a simple primary closure to a delayed restoration of bowel continuity. When the condition of the bowel or patient is frail, the risk of a failure of a closure or anastomosis is too high, and the exteriorization of the bowel defect as a primary measure is a safe option. The treatment of the peritonitis is also dependent on the condition of the patient and the local situation. Early stages of peritonitis can be treated by a simple peritoneal lavage, either performed by laparoscopy or laparotomy. Severe forms of peritonitis with multi-organ failure and an abdominal compartment syndrome need repeated peritoneal revisions. In such cases, the abdomen can only be closed temporarily. Different technical options are available in order to overcome the difficult care of these patients.

  16. Analysis of colonoscopic perforations at a local clinic and a tertiary hospital.

    Science.gov (United States)

    Sagawa, Toshihiko; Kakizaki, Satoru; Iizuka, Haruhisa; Onozato, Yasuhiro; Sohara, Naondo; Okamura, Shinichi; Mori, Masatomo

    2012-09-21

    To define the clinical characteristics, and to assess the management of colonoscopic complications at a local clinic. A retrospective review of the medical records was performed for the patients with iatrogenic colon perforations after endoscopy at a local clinic between April 2006 and December 2010. Data obtained from a tertiary hospital in the same region were also analyzed. The underlying conditions, clinical presentations, perforation locations, treatment types (operative or conservative) and outcome data for patients at the local clinic and the tertiary hospital were compared. A total of 10  826 colonoscopies, and 2625 therapeutic procedures were performed at a local clinic and 32  148 colonoscopies, and 7787 therapeutic procedures were performed at the tertiary hospital. The clinic had no perforations during diagnostic colonoscopy and 8 (0.3%) perforations were determined to be related to therapeutic procedures. The perforation rates in each therapeutic procedure were 0.06% (1/1609) in polypectomy, 0.2% (2/885) in endoscopic mucosal resection (EMR), and 3.8% (5/131) in endoscopic submucosal dissection (ESD). Perforation rates for ESD were significantly higher than those for polypectomy or EMR (P hospital. Six perforations occurred with therapeutic endoscopy (perforation rate, 0.08%; 1 per 1298 procedures). Perforation rates for specific procedure types were 0.02% (1 per 5500) for polypectomy, 0.17% (1 per 561) for EMR, 2.3% (1 per 43) for ESD in the tertiary hospital. There were no differences in the perforation rates for each therapeutic procedure between the clinic and the tertiary hospital. The incidence of iatrogenic perforation requiring surgical treatment was quite low in both the clinic and the tertiary hospital. No procedure-related mortalities occurred. Performing closure with endoscopic clipping reduced the C-reactive protein (CRP) titers. The mean maximum CRP titer was 2.9 ± 1.6 mg/dL with clipping and 9.7 ± 6.2 mg/dL without clipping

  17. Perforated peptic ulcer in southeastern Taiwan.

    Science.gov (United States)

    Li, Chin-Hsien; Chang, Wen-Hsiung; Shih, Shou-Chuan; Lin, Shee-Chan; Bair, Ming-Jong

    2010-09-01

    No studies focus on the population with perforated peptic ulcer in southeastern Taiwan. The present study aimed to assess the differences between the different races and the risk factors related to mortality and morbidity in postoperative patients in southeastern Taiwan. The medical records of 237 patients were reviewed retrospectively. The following factors were analyzed: patient profiles, coexisting illnesses, diagnostic method, fever, preoperative shock, clinical data at emergency room, delay operation, site of perforation, operative method, positive ascites culture, species of microbes in ascites culture, postoperative complications, death and the length of hospital stay. Aborigines were significantly different from non-aborigines in the ratio of female cases and in the habits of alcohol drinking and betel nut chewing. There were also four significantly different variables between them: fever, hemoglobin value, site of perforation and operative method. Total postoperative complication rate was 41.3% and 39 patients (16.6%) died. In multivariate analysis, age > or = 65 years, lipase > upper normal limit and preoperative shock were independent predictors of mortality. Significant risk factors associated with morbidity were NSAIDs use, creatinine > 1.5 mg/dL and preoperative shock. Aborigines were different from non-aborigines in several categories. In southeastern Taiwan, NSAIDs use, creatinine > 1.5 mg/dL and preoperative shock were independent risk factors of morbidity, and age > or = 65 years, lipase > upper normal limit and preoperative shock were independent risk factors of mortality in postoperative perforated peptic ulcer. Lipase > upper normal limit is needed for further research on the influence on mortality.

  18. Pipe damping

    International Nuclear Information System (INIS)

    Ware, A.G.; Arendts, J.G.

    1984-01-01

    A program has been developed to assess the available piping damping data, to generate additional data and conduct seperate effects tests, and to establish a plan for reporting and storing future test results into a data bank. This effort is providing some of the basis for developing higher allowable damping values for piping seismic analyses, which will potentially permit removal of a considerable number of piping supports, particularly snubbers. This in turn will lead to more flexible piping systems which will be less susceptible to thermal cracking, will be easier to maintain and inspect, as well as less costly

  19. Case report: Stercoral sigmoid colonic perforation with fecal peritonitis

    International Nuclear Information System (INIS)

    Sharma, Monika; Agrawal, Anjali

    2010-01-01

    Chronic constipation can lead to fecal impaction. It can also rarely lead to catastrophic complications like perforation, colonic obstruction, and fecal peritonitis. We report a rare case of stercoral sigmoid colonic perforation with fecal peritonitis and pneumoperitoneum, which was diagnosed on preoperative CT scan

  20. Generalized multiscale finite element methods for problems in perforated heterogeneous domains

    KAUST Repository

    Chung, Eric T.

    2015-06-08

    Complex processes in perforated domains occur in many real-world applications. These problems are typically characterized by physical processes in domains with multiple scales. Moreover, these problems are intrinsically multiscale and their discretizations can yield very large linear or nonlinear systems. In this paper, we investigate multiscale approaches that attempt to solve such problems on a coarse grid by constructing multiscale basis functions in each coarse grid, where the coarse grid can contain many perforations. In particular, we are interested in cases when there is no scale separation and the perforations can have different sizes. In this regard, we mention some earlier pioneering works, where the authors develop multiscale finite element methods. In our paper, we follow Generalized Multiscale Finite Element Method (GMsFEM) and develop a multiscale procedure where we identify multiscale basis functions in each coarse block using snapshot space and local spectral problems. We show that with a few basis functions in each coarse block, one can approximate the solution, where each coarse block can contain many small inclusions. We apply our general concept to (1) Laplace equation in perforated domains; (2) elasticity equation in perforated domains; and (3) Stokes equations in perforated domains. Numerical results are presented for these problems using two types of heterogeneous perforated domains. The analysis of the proposed methods will be presented elsewhere. © 2015 Taylor & Francis

  1. MEASUREMENT AND MODELLING OF SORPTION EQUILIBRIUM CURVE OF WATER ON PA6, PP, HDPE AND PVC BY USING FLORY-HUGGINS MODEL

    Directory of Open Access Journals (Sweden)

    Suherman Suherman

    2012-02-01

    Full Text Available The sorption of water on granular polyamide-6 (PA6, granular polypropylene (PP, and powdery high density polyethylene (HDPE and powdery polyvinyl chloride (PVC were measured using a gravimetric method in a magnetic suspension balance (MSB. The Flory-Huggins model was successfully applied on the sorption equilibrium curve of all investigated polymers. The influence of temperature is low. The value of Flory-Huggins parameters(c of PA6, PVC, PP and HDPE were 1.8, 5.8, 6.3, and 8.1, respectively. The water in PA6 is mainly bound moisture, while in PP, HDPE and PVC it is mainly surface moisture.

  2. Colonic perforation with peritonitis in amoebiasis: a tropical disease with high mortality.

    Science.gov (United States)

    Jain, Bhupendra Kumar; Garg, Pankaj Kumar; Kumar, Anjay; Mishra, Kiran; Mohanty, Debajyoti; Agrawal, Vivek

    2013-01-01

    Invasive colonic amoebiasis presents primarily with dysentery; colonic perforation occurs rarely. Cases of amoebic colonic perforations have been reported sporadically over the past 20 years. A retrospective study was done in the surgical unit of a tertiary care hospital in North India. The case records of those patients were reviewed who underwent exploratory laparotomy from January 2011 to September 2012 and were diagnosed with amoebic colonic perforation on histopathological examination. Details concerning the clinical presentation, investigations, intraoperative findings, operative procedures, and postoperative outcomes were retrieved. Amongst, a total of 186 emergency exploratory laparotomies carried out during the study, 15 patients of amoebic colonic perforation were identified. The median age of the patients was 42 years (IQR 32.0-58.0) and the male to female ratio was 13:2. Previous history of colitis was present in only 1 patient. The preoperative diagnosis was perforation peritonitis in 12 patients; and intussusception, intestinal obstruction and ruptured liver abscess in 1 patient each. Ten patients had single perforation while 5 had multiple colonic perforations. All the patients except one had perforations in the right colon. Bowel resection was performed depending upon the site and extent of the colon involved-right hemicolectomy (8), limited ileocolic resection (6) and sigmoidectomy (1). Bowel continuity could be restored only in 2 of the 15 patients and a stoma was constructed in the remaining 13 patients. The overall mortality rate was found to be 40% (6/15). Amoebic colonic perforation is associated with unusually high mortality.

  3. [Laparoscopic surgery for perforated peptic ulcer].

    Science.gov (United States)

    Yasuda, Kazuhiro; Kitano, Seigo

    2004-03-01

    Laparoscopic surgery has become the treatment of choice for the management of perforated peptic ulcer. The advantages of laparoscopic repair for perforated peptic ulcer include less pain, a short hospital stay, and an early return to normal activity. Although the operation time of laparoscopic surgery is significantly longer than that of open surgery, laparoscopic technique is safe, feasible, and with morbidity and mortality comparable to that of the conventional open technique. To benefit from the advantages offered by minimally invasive laparoscopic technique, further study will need to determine whether laparoscopic surgery is safe in patients with generalized peritonitis or sepsis.

  4. Insulated pipe clamp design

    International Nuclear Information System (INIS)

    Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

    1980-01-01

    Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. The design considerations and methods along with the development tests are presented. Special considerations to guard against adverse cracking of the insulation material, to maintain the clamp-pipe stiffness desired during a seismic event, to minimize clamp restraint on the pipe during normal pipe heatup, and to resist clamp rotation or spinning on the pipe are emphasized

  5. Preparation of Drug-loaded Chitosan Microspheres and Its Application in Paper-based PVC Wallpaper

    Science.gov (United States)

    Lin, Hui; Chen, Lihui; Yan, Guiyang; Chen, Feng; Huang, Liulian

    2018-03-01

    By screening through test, it was found that the drug-loaded chitosan microspheres with the average particle size of 615 nm may be prepared with NaF as the mold-proof drug, chitosan as the drug carrier and sodium tripolyphosphate as the cross-linking agent; and they can improve the aspergillus niger-proof effect if loaded onto the base paper surface of the paper-based PVC wallpaper. The results show that NaF and chitosan have mold-proof synergistic effects; the mold-proof effect of the wallpaper may be improved by increasing the dose of chitosan; when the mass ratio of NaF, sodium tripolyphosphate and chitosan was 2:7:28, the paper-based PVC wallpaper with good mold-proof property can be prepared.

  6. Perforated Meckel's diverticulum in omphalocele

    OpenAIRE

    Jin, Hanna; Han, Ji-Won; Oh, Chaeyoun; Kim, Hyun-Young; Jung, Sung-Eun

    2017-01-01

    Meckel's diverticulum is a rare condition in neonates with reports of concurrent Meckel's diverticulum and omphalocele being few. Herein, we present a case of omphalocele associated with perforated Meckel's diverticulum.

  7. Perforated Meckel's diverticulitis complicating active Crohn's ileitis: a case report.

    Science.gov (United States)

    Schwenter, Frank; Gervaz, Pascal; de Saussure, Philippe; McKee, Thomas; Morel, Philippe

    2009-01-13

    In Crohn's disease, the extension of active terminal ileitis into a Meckel's diverticulum is possible, but usually has no impact on clinical decision-making. We describe an original surgical approach in a young woman presenting with a combination of perforated Meckel's diverticulitis and active Crohn's ileitis. We report the case of a 22-year-old woman with Crohn's disease, who was admitted for abdominal pain, fever and diarrhoea. CT scan demonstrated active inflammation of the terminal ileum, as well as a fluid collection in the right iliac fossa, suggesting intestinal perforation. Laparoscopy was performed and revealed, in addition to extensive ileitis, a 3 x 3 cm abscess in connection with perforated Meckel's diverticulitis. It was therefore possible to avoid ileocaecal resection by only performing Meckel's diverticulectomy; pathological examination of the surgical specimen revealed the presence of transmural inflammation with granulomas and perforation of the diverticulum at its extremity. Crohn's disease of the ileum may be responsible for Meckel's diverticulitis and cause perforation which, in this case, proved to be a blessing in disguise and spared the patient an extensive small bowel resection.

  8. A Five-Year Review of Perforated Peptic Ulcer Disease in Irrua, Nigeria.

    Science.gov (United States)

    Dongo, A E; Uhunmwagho, O; Kesieme, E B; Eluehike, S U; Alufohai, E F

    2017-01-01

    Peptic ulcer perforation is a common cause of emergency admission and surgery. This is the first study that documents the presentation and outcome of management in Irrua, Nigeria. This is a prospective study of all patients operated on for perforated peptic ulcer between April 1, 2010, and March 31, 2015. A structured questionnaire containing patients' demographics, operation findings, and outcome was filled upon discharge or death. There were 104 patients. 81 males and 23 females (M : F = 3.5 : 1). The age range was between 17 years and 95 years. The mean age was 48.99 years ± SD 16.1 years. The ratio of gastric to duodenal perforation was 1.88 : 1. Perforation was the first sign of peptic ulcer disease in 62 (59.6%). Pneumoperitoneum was detectable with plain radiographs in 95 (91%) patients. 72 (69.2%) had Graham's Omentopexy. Death rate was 17.3%. We note that gastric perforation is a far commoner disease in our environment. Perforation is often the first sign of peptic ulcer disease. We identify fasting amongst Christians as a risk factor for perforation.

  9. Spontaneous perforation of sigmoid colon in a child with acute lymphoblastic leukemia

    Directory of Open Access Journals (Sweden)

    Miolski Jelena

    2017-01-01

    Full Text Available Introduction. Perforation of the sigmoid colon is rare in children and its descriptions in medical literature are infrequent. Case Outline. In a 13-year-old boy with acute lymphoblastic leukemia, a ten-month course of chemotherapy was accompanied by many complications: parasitic infestation (Enterobius vermicularis, lung candidiasis, esophageal candidiasis, steroid diabetes, anaphylactoid reaction to L-asparaginase, febrile neutropenia, mucositis, anemia, thrombocytopenia, enterocolitis, and respiratory distress syndrome. During reinduction treatment, consisting of dexamethasone, vincristine, doxorubicin, and crisantaspase, he complained of abdominal pain and, upon radiographic examination, was found to have pneumoperitoneum. Because of suspicion of abdominal hollow organ perforation, he was subjected to explorative laparotomy, which yielded the diagnosis of perforation of the sigmoid colon. Conclusion. After an extensive review of the published reports on sigmoid perforation, all associated conditions that could possibly induce perforation – such as Hirschsprung’s disease or foreign body – were systematically excluded in our patient. Although typhlitis was the first diagnostic hypothesis, this was excluded by intraoperative findings, histopathology, and perforation site. To the best of our knowledge, this is the first report of a spontaneous perforation of the sigmoid colon in a child with acute lymphoblastic leukemia.

  10. Laparoscopic management of duodenal ulcer perforation: is it advantageous?

    Science.gov (United States)

    Palanivelu, C; Jani, Kalpesh; Senthilnathan, P

    2007-01-01

    Surgery is the mainstay of treatment of patients with peptic duodenal perforation. With the advent of minimal access techniques, laparoscopy is being used for the treatment of this condition. Retrospective analysis of 120 consecutive patients (mean age 44.5 years; 111 men) with duodenal ulcer perforation who had undergone laparoscopic surgery. 87 patients had history of tobacco consumption, 12 were chronic NSAID users, 72 had Helicobacter pylori infection and 36 had a co-morbid condition. The mean time to surgery from onset of symptoms was 28.4 hours. The median operating time was 46 minutes. All patients underwent laparoscopic closure of the perforation with Graham's patch omentopexy; 12 patients underwent additional definitive ulcer surgery. The morbidity rate was 7.5%; no patient needed conversion to open surgery or died. The mean postoperative hospital stay was 5.8 days. Results of laparoscopic management of perforated peptic ulcer are encouraging, with no conversion to open surgery, low morbidity and no mortality.

  11. Corneal perforation after conductive keratoplasty with previous refractive surgery.

    Science.gov (United States)

    Kymionis, George D; Titze, Patrik; Markomanolakis, Marinos M; Aslanides, Ioannis M; Pallikaris, Ioannis G

    2003-12-01

    A 56-year-old woman had conductive keratoplasty (CK) for residual hyperopia and astigmatism. Three years before the procedure, the patient had arcuate keratotomy, followed by laser in situ keratomileusis 2 years later for high astigmatism correction in both eyes. During CK, a corneal perforation occurred in the right eye; during the postoperative examination, an iris perforation and anterior subcapsule opacification were seen beneath the perforation site. The perforation was managed with a bandage contact lens and an antibiotic-steroid ointment; it had a negative Seidel sign by the third day. The surgery in the left eye was uneventful. Three months after the procedure, the uncorrected visual acuity was 20/32 and the best corrected visual acuity 20/20 in both eyes with a significant improvement in corneal topography. Care must be taken to prevent CK-treated spots from coinciding with areas in the corneal stroma that might have been altered by previous refractive procedures.

  12. Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes

    Directory of Open Access Journals (Sweden)

    Eman Y. Z. Frag

    2011-01-01

    Full Text Available This study compares between unmodified carbon paste (CPE; the paste has no ion pair and polyvinyl chloride (PVC membrane selective electrodes that were used in potentiometric determination of ketotifen fumarate (KTF, where sodium tetraphenylborate (NaTPB was used as titrant. The performance characteristics of these sensors were evaluated according to IUPAC recommendations which reveal a fast, stable, and linear response for KTF over the concentration range of 10−7 to 10−2 mol L−1. The electrodes show Nernstian slope value of 52.51±0.20 and 51.51±0.25 mV decade−1 for CPE and PVC membrane electrodes at 30∘C, respectively. The potential is nearly stable over the pH range 3.0–6.0 and 2.0–7.0 for CPE and PVC membrane electrodes, respectively. Selectivity coefficient values towards different inorganic cations, sugars, and amino acids reflect high selectivity of the prepared electrodes. The electrodes responses at different temperatures were also studied, and long operational lifetime of 12 and 5 weeks for CPE and PVC membrane electrodes, respectively, were found. These are used for determination of ketotifen fumarate using potentiometric titration, calibration, and standard addition methods in pure samples, its pharmaceutical preparations (Zaditen tablets, and biological fluid (urine. The direct potentiometric determination of KTF using the proposed sensors gave recoveries % of 98.97±0.53 and 98.62±0.74 with RSD 1.42 and 0.63% for CPE and PVC membrane selective electrodes, respectively. Validation of the method shows suitability of the proposed sensors for use in quality control assessment of KTF. The obtained results were in a good agreement with those obtained using the reported spectrophotometric method.

  13. Potentiometric determination of ketotifen fumarate in pharmaceutical preparations and urine using carbon paste and PVC membrane selective electrodes.

    Science.gov (United States)

    Frag, Eman Y Z; Mohamed, Gehad G; Khalil, Mohamed M; Hwehy, Mohammad M A

    2011-01-01

    This study compares between unmodified carbon paste (CPE; the paste has no ion pair) and polyvinyl chloride (PVC) membrane selective electrodes that were used in potentiometric determination of ketotifen fumarate (KTF), where sodium tetraphenylborate (NaTPB) was used as titrant. The performance characteristics of these sensors were evaluated according to IUPAC recommendations which reveal a fast, stable, and linear response for KTF over the concentration range of 10(-7) to 10(-2) mol L(-1). The electrodes show Nernstian slope value of 52.51 ± 0.20 and 51.51 ± 0.25 mV decade(-1) for CPE and PVC membrane electrodes at 30°C, respectively. The potential is nearly stable over the pH range 3.0-6.0 and 2.0-7.0 for CPE and PVC membrane electrodes, respectively. Selectivity coefficient values towards different inorganic cations, sugars, and amino acids reflect high selectivity of the prepared electrodes. The electrodes responses at different temperatures were also studied, and long operational lifetime of 12 and 5 weeks for CPE and PVC membrane electrodes, respectively, were found. These are used for determination of ketotifen fumarate using potentiometric titration, calibration, and standard addition methods in pure samples, its pharmaceutical preparations (Zaditen tablets), and biological fluid (urine). The direct potentiometric determination of KTF using the proposed sensors gave recoveries % of 98.97 ± 0.53 and 98.62 ± 0.74 with RSD 1.42 and 0.63% for CPE and PVC membrane selective electrodes, respectively. Validation of the method shows suitability of the proposed sensors for use in quality control assessment of KTF. The obtained results were in a good agreement with those obtained using the reported spectrophotometric method.

  14. An Experimentally Validated Numerical Modeling Technique for Perforated Plate Heat Exchangers.

    Science.gov (United States)

    White, M J; Nellis, G F; Kelin, S A; Zhu, W; Gianchandani, Y

    2010-11-01

    Cryogenic and high-temperature systems often require compact heat exchangers with a high resistance to axial conduction in order to control the heat transfer induced by axial temperature differences. One attractive design for such applications is a perforated plate heat exchanger that utilizes high conductivity perforated plates to provide the stream-to-stream heat transfer and low conductivity spacers to prevent axial conduction between the perforated plates. This paper presents a numerical model of a perforated plate heat exchanger that accounts for axial conduction, external parasitic heat loads, variable fluid and material properties, and conduction to and from the ends of the heat exchanger. The numerical model is validated by experimentally testing several perforated plate heat exchangers that are fabricated using microelectromechanical systems based manufacturing methods. This type of heat exchanger was investigated for potential use in a cryosurgical probe. One of these heat exchangers included perforated plates with integrated platinum resistance thermometers. These plates provided in situ measurements of the internal temperature distribution in addition to the temperature, pressure, and flow rate measured at the inlet and exit ports of the device. The platinum wires were deposited between the fluid passages on the perforated plate and are used to measure the temperature at the interface between the wall material and the flowing fluid. The experimental testing demonstrates the ability of the numerical model to accurately predict both the overall performance and the internal temperature distribution of perforated plate heat exchangers over a range of geometry and operating conditions. The parameters that were varied include the axial length, temperature range, mass flow rate, and working fluid.

  15. The posterolateral mid-forearm perforator flap: anatomical study and clinical application.

    Science.gov (United States)

    Zhuang, Yue-Hong; Lin, Jian; Fu, Fei-Huan; Cai, Zhen-De; Huang, Hui-Mei; Zheng, He-Ping

    2013-11-01

    Defects sustained at the distal forearm are common and pedicled perforator flaps have unique advantages in resurfacing it. The purpose of this study is to reappraise the anatomy of the perforator in the posterolateral aspect of the mid-forearm and present our clinical experience on using perforator flaps based on it for reconstruction of defects in the distal forearm. This study was divided into anatomical study and clinical application. In the anatomical study, 30 preserved upper limbs were used. Clinically, 11 patients with defects at the forearm underwent reconstruction with the posterolateral mid-forearm perforator flaps. The defects, ranging from 4.5 × 2.5 cm to 10.5 × 4.5 cm, were located at the dorsal aspect of the distal forearm in 6 cases and at the volar aspect of the distal forearm in 5 cases. Three patterns of the perforator were observed in the posterolateral aspect of the mid-forearm, which originated from the posterior interosseous artery, the proximal segment of the radial artery or the radial recurrent artery, and the middle segment of the radial artery, respectively. The perforator was located 11.8 ± 0.2 cm to 15.8 ± 0.4 cm inferior to the lateral humeral epicondyle. Clinically, flaps in 8 cases survived uneventfully, while the other 3 cases suffered mild marginal epidermal necrosis, which was cured with continuous dress changing. The location of the perforator at the posterolateral aspect of the mid-forearm is consistent; the posterolateral mid-forearm perforator flap is particularly suitable to cover defects in the distal one-third of the forearm. Copyright © 2013 Wiley Periodicals, Inc.

  16. Three-dimensional numerical simulation of wave interaction with perforated quasi-ellipse caisson

    Directory of Open Access Journals (Sweden)

    Yong-xue Wang

    2011-03-01

    Full Text Available The finite difference method and the volume of fluid (VOF method were used to develop a three-dimensional numerical model to study wave interaction with a perforated caisson. The partial cell method was adopted to solve this type of problem for the first time. The validity of the present model, with and without the presence of caisson structures, was examined by comparing the model results with experimental data. Then, the numerical model was used to investigate the effects of various wave and structure parameters on the wave force and wave runup of the perforated quasi-ellipse caisson. Compared with the solid quasi-ellipse caisson, the wave force on the perforated quasi-ellipse caisson is significantly reduced with increasing porosity of the perforated quasi-ellipse caisson. Furthermore, the perforated quasi-ellipse caisson can also reduce the wave runup, and it tends to decrease with the increase of the porosity of the perforated quasi-ellipse caisson and the relative wave height.

  17. Fundamentals of piping design

    CERN Document Server

    Smith, Peter

    2013-01-01

    Written for the piping engineer and designer in the field, this two-part series helps to fill a void in piping literature,since the Rip Weaver books of the '90s were taken out of print at the advent of the Computer Aid Design(CAD) era. Technology may have changed, however the fundamentals of piping rules still apply in the digitalrepresentation of process piping systems. The Fundamentals of Piping Design is an introduction to the designof piping systems, various processes and the layout of pipe work connecting the major items of equipment forthe new hire, the engineering student and the vetera

  18. Heat pipe

    International Nuclear Information System (INIS)

    Triggs, G.W.; Lightowlers, R.J.; Robinson, D.; Rice, G.

    1986-01-01

    A heat pipe for use in stabilising a specimen container for irradiation of specimens at substantially constant temperature within a liquid metal cooled fast reactor, comprises an evaporator section, a condenser section, an adiabatic section therebetween, and a gas reservoir, and contains a vapourisable substance such as sodium. The heat pipe further includes a three layer wick structure comprising an outer relatively fine mesh layer, a coarse intermediate layer and a fine mesh inner layer for promoting unimpeded return of condensate to the evaporation section of the heat pipe while enhancing heat transfer with the heat pipe wall and reducing entrainment of the condensate by the upwardly rising vapour. (author)

  19. Peritonitis by jejunal ulcer perforation in a child: a case report

    Directory of Open Access Journals (Sweden)

    Ndèye Aby Ndoye

    2017-01-01

    Full Text Available Ulcer perforation is a rare cause of peritonitis in children. The cases reported in the literature are caused by peptic ulcer. We report on a case of peritonitis caused by jejunal ulcer perforation, discovered in a girl's abdomen during an acute surgical procedure. The treatment consisted of a resection of the perforation followed by an end-to-end anastomosis. Postoperative period was uneventful.

  20. Single center experience in laparoscopic treatment of gallbladder perforation.

    Science.gov (United States)

    Sahbaz, Nuri Alper; Peker, Kivanc Derya; Kabuli, Hamit Ahmet; Gumusoglu, Alpen Yahya; Alis, Halil

    2017-12-01

    Gallbladder perforation (GBP) is a rare disease with potential mortality. Previous series have reported an incidence of approximately 2-11% and it still continues to be a significant problem for surgeons. To present our clinical experience with gallbladder perforation. The records of 2754 patients who received surgical treatment for cholelithiasis between 2010 and 2016 were reviewed retrospectively. One hundred thirty-three patients had gallbladder perforation. Age, gender, time from the onset of symptoms, diagnostic procedures, surgical treatment, morbidity and mortality rates were evaluated. 15.78% of patients had a body mass index > 35. 6.76% had chronic obstructive pulmonary disease, 6.76% had cardiac disease, 10.52% had diabetes and 4.51% had sepsis. American Society of Anesthesiology scores were I in 54.13%, II in 35.33%, III in 6.01% and IV in 4.51% of the patients. 27.81% of patients were diagnosed during surgery. The perforation site was the gallbladder fundus in 69.17%, body in 17.30%, Hartman's pouch in 10.53% and cystic duct in 3% of patients. Treatment modalities were laparoscopic cholecystectomy in 82.71%, open cholecystectomy in 3%, percutaneous drainage catheters + laparoscopic cholecystectomy in 3%, laparoscopic cholecystectomy + fistula repair in 10.53% and open cholecystectomy + fistula repair in 0.75% of patients. Mean length of hospital stay was 1.69 days. Mortality and morbidity rates were 8.27% and 10.52%, respectively. Histopathology results were acute cholecystitis in 69.93%, chronic cholecystitis in 20.30% and acute exacerbation over chronic cholecystitis in 9.77% of patients. Appropriate classification and management of perforated cholecystitis is essential. Laparoscopic cholecystectomy is a safe and feasible method to decrease morbidity in gallbladder perforations.

  1. Perforated peptic ulcer - an update.

    Science.gov (United States)

    Chung, Kin Tong; Shelat, Vishalkumar G

    2017-01-27

    Peptic ulcer disease (PUD) affects 4 million people worldwide annually. The incidence of PUD has been estimated at around 1.5% to 3%. Perforated peptic ulcer (PPU) is a serious complication of PUD and patients with PPU often present with acute abdomen that carries high risk for morbidity and mortality. The lifetime prevalence of perforation in patients with PUD is about 5%. PPU carries a mortality ranging from 1.3% to 20%. Thirty-day mortality rate reaching 20% and 90-d mortality rate of up to 30% have been reported. In this review we have summarized the current evidence on PPU to update readers. This literature review includes the most updated information such as common causes, clinical features, diagnostic methods, non-operative and operative management, post-operative complications and different scoring systems of PPU. With the advancement of medical technology, PUD can now be treated with medications instead of elective surgery. The classic triad of sudden onset of abdominal pain, tachycardia and abdominal rigidity is the hallmark of PPU. Erect chest radiograph may miss 15% of cases with air under the diaphragm in patients with bowel perforation. Early diagnosis, prompt resuscitation and urgent surgical intervention are essential to improve outcomes. Exploratory laparotomy and omental patch repair remains the gold standard. Laparoscopic surgery should be considered when expertise is available. Gastrectomy is recommended in patients with large or malignant ulcer.

  2. Perforated peptic ulcer - an update

    Science.gov (United States)

    Chung, Kin Tong; Shelat, Vishalkumar G

    2017-01-01

    Peptic ulcer disease (PUD) affects 4 million people worldwide annually. The incidence of PUD has been estimated at around 1.5% to 3%. Perforated peptic ulcer (PPU) is a serious complication of PUD and patients with PPU often present with acute abdomen that carries high risk for morbidity and mortality. The lifetime prevalence of perforation in patients with PUD is about 5%. PPU carries a mortality ranging from 1.3% to 20%. Thirty-day mortality rate reaching 20% and 90-d mortality rate of up to 30% have been reported. In this review we have summarized the current evidence on PPU to update readers. This literature review includes the most updated information such as common causes, clinical features, diagnostic methods, non-operative and operative management, post-operative complications and different scoring systems of PPU. With the advancement of medical technology, PUD can now be treated with medications instead of elective surgery. The classic triad of sudden onset of abdominal pain, tachycardia and abdominal rigidity is the hallmark of PPU. Erect chest radiograph may miss 15% of cases with air under the diaphragm in patients with bowel perforation. Early diagnosis, prompt resuscitation and urgent surgical intervention are essential to improve outcomes. Exploratory laparotomy and omental patch repair remains the gold standard. Laparoscopic surgery should be considered when expertise is available. Gastrectomy is recommended in patients with large or malignant ulcer. PMID:28138363

  3. Treatment of PVC using an alternative low energy ion bombardment procedure

    Science.gov (United States)

    Rangel, Elidiane C.; dos Santos, Nazir M.; Bortoleto, José Roberto R.; Durrant, Steven F.; Schreiner, Wido H.; Honda, Roberto Y.; Rangel, Rita de Cássia C.; Cruz, Nilson C.

    2011-12-01

    In many applications, polymers have progressively substituted traditional materials such as ceramics, glasses, and metals. Nevertheless, the use of polymeric materials is still limited by their surface properties. Frequently, selective modifications are necessary to suit the surface to a given application. Amongst the most common treatments, plasma immersion ion implantation (PIII) has attracted the attention of many researchers owing to its versatility and practicality. This method, however, requires a power supply to provide high voltage (tens of kV) negative pulses, with a controlled duty cycle, width and frequency. Owing to this, the implementation of PIII on the industrial scale can become economically inviable. In this work, an alternative plasma treatment that enables low energy ion bombardment without the need of a high voltage pulse generator is presented. To evaluate the efficiency of the treatment of polymers, polyvinylchloride, PVC, specimens were exposed to 5 Pa argon plasmas for 3600 s, at excitation powers, P, of between 10 and 125 W. Through contact angle and atomic force microscopy data, the influence of P on the wettability, surface free energy and roughness of the samples was studied. Surface chemical composition was measured by X-ray photoelectron spectroscopy, XPS. To evaluate the effect of aging under atmospheric conditions, contact angle and XPS measurements were performed one and 1334 days after the treatment. The plasma potential and ion density around the driven electrode were determined from Langmuir probe measurements while the self-bias potential was derived with the aid of an oscilloscope. From these data it was possible to estimate the mean energy of ions bombarding the PVC surface. Chlorine, carbon and oxygen contamination were detected on the surface of the as-received PVC. Upon exposure to the plasma, the proportion of chlorine was observed to decrease while that of oxygen increased. Consequently, the wettability and surface energy

  4. Treatment of PVC using an alternative low energy ion bombardment procedure

    International Nuclear Information System (INIS)

    Rangel, Elidiane C.; Santos, Nazir M. dos; Bortoleto, José Roberto R.; Durrant, Steven F.; Schreiner, Wido H.; Honda, Roberto Y.; Cássia C Rangel, Rita de; Cruz, Nilson C.

    2011-01-01

    In many applications, polymers have progressively substituted traditional materials such as ceramics, glasses, and metals. Nevertheless, the use of polymeric materials is still limited by their surface properties. Frequently, selective modifications are necessary to suit the surface to a given application. Amongst the most common treatments, plasma immersion ion implantation (PIII) has attracted the attention of many researchers owing to its versatility and practicality. This method, however, requires a power supply to provide high voltage (tens of kV) negative pulses, with a controlled duty cycle, width and frequency. Owing to this, the implementation of PIII on the industrial scale can become economically inviable. In this work, an alternative plasma treatment that enables low energy ion bombardment without the need of a high voltage pulse generator is presented. To evaluate the efficiency of the treatment of polymers, polyvinylchloride, PVC, specimens were exposed to 5 Pa argon plasmas for 3600 s, at excitation powers, P, of between 10 and 125 W. Through contact angle and atomic force microscopy data, the influence of P on the wettability, surface free energy and roughness of the samples was studied. Surface chemical composition was measured by X-ray photoelectron spectroscopy, XPS. To evaluate the effect of aging under atmospheric conditions, contact angle and XPS measurements were performed one and 1334 days after the treatment. The plasma potential and ion density around the driven electrode were determined from Langmuir probe measurements while the self-bias potential was derived with the aid of an oscilloscope. From these data it was possible to estimate the mean energy of ions bombarding the PVC surface. Chlorine, carbon and oxygen contamination were detected on the surface of the as-received PVC. Upon exposure to the plasma, the proportion of chlorine was observed to decrease while that of oxygen increased. Consequently, the wettability and surface energy

  5. Medical image of the week: eosphageal perforation

    Directory of Open Access Journals (Sweden)

    Bilal J

    2015-04-01

    Full Text Available No abstract available. Article truncated after 150 words. A 74 year old man with a past medical history of esophageal strictures status post dilatation, coronary artery disease status post CABG, and atrial fibrillation presented to hospital with complaints of severe chest pain that began after the consumption of tortilla chips one hour prior to presentation. Electrocardiogram and cardiac enzymes were not consistent with acute coronary syndrome. Chest X-ray was consistent with a widened mediastinal silhouette. Contrast esophogram was negative for extra luminal extravasation. CT scan of the chest with oral contrast demonstrated thickening of the mid-thoracic esophagus with an extra-luminal focus of gas in the mediastinum along with fluid along the inferior aspect of the esophagus (Figures 1 and 2. These findings were concerning for esophageal perforation. The patient was taken to the operating room for endoscopy which showed micro perforation in mid-esophagus. Esophageal perforation remains a highly morbid condition. Mortality rates are based predominantly on time of ...

  6. Use of Computed Tomography to Determine Perforation in Patients With Acute Appendicitis.

    Science.gov (United States)

    Gaskill, Cameron E; Simianu, Vlad V; Carnell, Jonathan; Hippe, Daniel S; Bhargava, Puneet; Flum, David R; Davidson, Giana H

    Urgent appendectomy has long been the standard of care for acute appendicitis. Six randomized trials have demonstrated that antibiotics can safely treat appendicitis, but approximately 1 in 4 of these patients eventually requires appendectomy. Overall treatment success may be limited by complex disease including perforation. Patients׳ success on antibiotic therapy may depend on preoperative identification of complex disease on imaging. However, the effectiveness of computed tomography (CT) in differentiating complex disease including perforated from nonperforated appendicitis remains to be determined. The purpose of this study was to assess the preoperative diagnostic accuracy of CT in determining appendiceal perforation in patients operated for acute appendicitis. We performed a retrospective review of pathology and radiology reports from consecutive patients who presented to the emergency department with suspicion for acute appendicitis between January 2012 and May 2015. CT scans were re-reviewed by abdominal imaging fellowship-trained radiologists using standardized criteria, and the radiologists were blinded to pathology and surgical findings. Radiologists specifically noted presence or absence of periappendiceal gas, abscess, appendicolith, fat stranding, and bowel wall thickening. The overall radiologic impression as well as these specific imaging findings was compared to results of pathology and operative reports. Pathology reports were considered the standard for diagnostic accuracy. Eighty-nine patients (65% male, average age of 34 years) presenting with right lower quadrant pain underwent CT imaging and prompt appendectomy. Final pathology reported perforation in 48% (n = 43) of cases. Radiologic diagnosis of perforation was reported in 9% (n = 8), correctly identifying perforation in 37.5% (n = 3), and incorrectly reporting perforation in 62.5% of nonperforated cases per pathology. Radiology missed 93% (n = 40) of perforations postoperatively diagnosed

  7. Perforated Meckel's diverticulum in omphalocele

    Directory of Open Access Journals (Sweden)

    Hanna Jin

    2017-02-01

    Full Text Available Meckel's diverticulum is a rare condition in neonates with reports of concurrent Meckel's diverticulum and omphalocele being few. Herein, we present a case of omphalocele associated with perforated Meckel's diverticulum.

  8. The use of artificial neural networks for mathematical modeling of the effect of composition and production conditions on the properties of PVC floor coverings

    Directory of Open Access Journals (Sweden)

    Radovanović Rajko M.

    2017-01-01

    Full Text Available The application of PVC floor coverings is strongly connected with their end-use properties, which depend on the composition and processing conditions. It is very difficult to estimate the proper influence of the production parameters on the characteristics of PVC floor coverings due to their complex composition and various preparation procedures. The effect of different processing variables (such as time of bowling, temperature of bowling and composition of PVC plastisol on the mechanical properties of PVC floor coverings was investigated. The influence of different input parameters on the mechanical properties was successfully determined using an artificial neural network with an optimized number of hidden neurons. The Garson and Yoon models were applied to calculate and describe the variable contributions in the artificial neural networks. [Projekat Ministarstva nauke Republike Srbije, br. III 45022

  9. Vitrectomy in double-perforation gunshot injury

    Directory of Open Access Journals (Sweden)

    Abd El Alim Mohamed A

    2013-11-01

    Full Text Available Ahmed Abd El Alim MohamedOphthalmology department, Ain Shams University, Cairo, EgyptObjective: This study sought to evaluate the result of pars plana vitrectomy in patients with gunshot wounds involving double perforation.Methods: This was a retrospective, noncomparative, interventional case series.Results: Eighteen patients (18 eyes with double-perforation gunshot injuries were treated from February 2010 to March 2012. The group included 16 men (88% and two women (11%; the mean age was 24 (15–33 years. In each case, vitrectomy was scheduled 1–6 weeks after repair of the entrance site. Associated retinal detachments were observed in two eyes (11%, retinal incarceration was observed surrounding the exit site in three eyes (16%, and retention of an intraocular foreign body was observed in two cases. After a follow-up period of 8 ± 2 months, two eyes (11% had achieved visual acuity (VA of 0.5, nine eyes (50% had achieved VA between 0.5 and 0.1, and seven eyes (38% had achieved VA between 0.1 and hand movement. The main reasons for functional failure (VA 0.1 to hand movement were macular dragging (due to fibrosis at the exit site near the macula in seven cases (38%, submacular hemorrhage in four cases (22%, and epimacular fibrosis in five cases (27%. All cases developed postoperative exotropia. One case (5% developed postoperative hemorrhage. No cases exhibited signs of postoperative redetachment.Conclusion: The outcome of pars plana vitrectomy in cases with double perforations is variable. Factors including the surgeon's skill level, the time to surgery, and the efficacy of the intraocular tamponade affect the postoperative outcome.Keywords: pars plana vitrectomy, gunshot injury, double perforation

  10. Lack of utility of measuring serum bilirubin concentration in distinguishing perforation status of pediatric appendicitis.

    Science.gov (United States)

    Bonadio, William; Bruno, Santina; Attaway, David; Dharmar, Logesh; Tam, Derek; Homel, Peter

    2017-06-01

    Pediatric appendicitis is a common, potentially serious condition. Determining perforation status is crucial to planning effective management. Determine the efficacy of serum total bilirubin concentration [STBC] in distinguishing perforation status in children with appendicitis. Retrospective review of 257 cases of appendicitis who received abdominal CT scan and measurement of STBC. There were 109 with perforation vs 148 without perforation. Although elevated STBC was significantly more common in those with [36%] vs without perforation [22%], the mean difference in elevated values between groups [0.1mg/dL] was clinically insignificant. Higher degrees of hyperbilirubinemia [>2mg/dL] were rarely encountered [5%]. Predictive values for elevated STBC in distinguishing perforation outcome were imprecise [sensitivity 38.5%, specificity 78.4%, PPV 56.8%, NPV 63.4%]. ROC curve analysis of multiple clinical and other laboratory factors for predicting perforation status was unenhanced by adding the STBC variable. Specific analysis of those with perforated appendicitis and percutaneously-drained intra-abdominal abscess which was culture-positive for Escherichia coli showed an identical rate of STBC elevation compared to all with perforation. The routine measurement of STBC does not accurately distinguish perforation status in children with appendicitis, nor discern infecting organism in those with perforation and intra-abdominal abscess. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. An unusual cause of duodenal perforation due to a lollipop stick

    Directory of Open Access Journals (Sweden)

    Mi Jin Kim

    2013-04-01

    Full Text Available Children have a natural tendency to explore objects with their mouths; this can result in the swallowing of foreign objects. Most ingested foreign bodies pass uneventfully through the gastrointestinal tract.However, some foreign bodies cause obstruction or perforation of the gastrointestinal tract, requiring surgical intervention. Perforation of the gastrointestinal tract may be associated with considerable morbidity and mortality. The most common sites of intestinal foreign body perforation are the ileocecal and rectosigmoid regions. Foreign body perforation of the duodenum is relatively uncommon. We report the first Korean case of duodenal perforation by an ingested 8-cm lollipop stick. Lollipops are popular with the children and fairly accessible to them, as most parents are not aware of their potential harm. Pediatric clinicians should be aware of the risks associated with lollipop stick ingestion. Our report also describes the feasibility and safety of laparoscopic diagnosis and management of pediatric patients with peritonitis induced by the ingestion of foreign bodies.

  12. Endoscopic Management of Gastrointestinal Leaks and Perforation with Polyglycolic Acid Sheets

    Directory of Open Access Journals (Sweden)

    Sojung Han

    2017-05-01

    Full Text Available Gastrointestinal (GI leakage, fistulae, and perforations can be serious and life threatening. There has been a paradigm shift in the management approach of these conditions, from surgical to conservative, including endoscopic management. Here, we report two cases of endoscopic closure of a GI fistula and perforation using polyglycolic acid (PGA sheets with fibrin glue. The first case is of an anastomotic leak detected after subtotal gastrectomy with gastroduodenostomy. After failed application of endoclips, a PGA sheet was applied, and the fistula was successfully closed. The second case was of a 15-mm large perforated gastric ulcer, which was also successfully closed with a PGA sheet. This is the first case report that PGA sheet was used for the treatment of overt perforation. The outcome of these cases suggest that endoscopic closure using PGA sheets can be considered as a useful alternative for the management of GI leakage, fistulae, and perforations.

  13. Heat pipe and method of production of a heat pipe

    International Nuclear Information System (INIS)

    Kemp, R.S.

    1975-01-01

    The heat pipe consists of a copper pipe in which a capillary network or wick of heat-conducting material is arranged in direct contact with the pipe along its whole length. Furthermore, the interior space of the tube contains an evaporable liquid for pipe transfer. If water is used, the capillary network consists of, e.g., a phosphorus band network. To avoid contamination of the interior of the heat pipe during sealing, its ends are closed by mechanical deformation so that an arched or plane surface is obtained which is in direct contact with the network. After evacuation of the interior space, the remaining opening is closed with a tapered pin. The ratio wall thickness/tube diameter is between 0.01 and 0.6. (TK/AK) [de

  14. Changing trend in emergency surgery for perforated duodenal ulcer

    International Nuclear Information System (INIS)

    Gurteyik, E.

    2003-01-01

    Objective: To evaluate changes in the emergency surgery of the duodenal ulcer. Subjects and Methods: Hospital records of 523 surgically treated patients, with duodenal ulcer perforation, during the period of 25 years 91975-1999) in the same surgical department, was retrospectively analysed. Changing aspects of emergency surgery of peptic ulcer disease, in the recent period, were determined in respect to number of operations per year and in the choice of operative methods. Results: The average number of patients and emergency operations per year was 21. No significant change was observed during the study period. Elective operations gradually decreased in the last ten years, and none was performed in the last 4 years. On the other hand, 226 emergency interventions for duodenal ulcer perforation were performed in the last ten years and 84 interventions in the last 4 years. Definitive anti-ulcer surgery was performed in 42% of patients between 1985 and 1994. Simple closure of the perforation plus treatment with proton pump inhibitors and with anti-Helicobacter pylori medication was the method in 80% during the last year. Conclusion: Emergency surgery for perforated duodenal ulcer preserves its steady rate despite disappearance of elective operations after tremendous progress in medical control of peptic ulcer disease. There is an obvious return from definitive anti-ulcer surgery to simple closure of the perforation followed by antisecretory and antibacterial medications in the recent years. (author)

  15. Gastric cancer perforation: experience from a tertiary care hospital.

    Science.gov (United States)

    Kandel, Bishnu Prasad; Singh, Yogendra; Singh, Keshav Prasad; Khakurel, Mahesh

    2013-01-01

    Gastric cancer perforation can occurs in advanced stage of the disease and is often associated with a high morbidity and mortality. Peritonitis due to perforation needs emergency laparotomy and different surgical procedures can be performed for definitive treatment. Surgical procedures largely depend on the stage of the disease and general condition of the patient. This study was carried out to evaluate the outcome and role of different surgical procedures in gastric cancer perforation. Medical record of patients with gastric perforation, who were treated during ten years period, was reviewed retrospectively. Data regarding clinical presentation, surgical procedures, staging and survival of patients were obtained. Features suggestive of diffuse peritonitis were evident in all cases. The majority of the patients underwent emergency surgery except one who died during resuscitation. The majority of patients were in stage III and stage IV. Surgical procedure includes simple closure and omental patch in five patients, simple closure and gastrojejunostomy in nine patients, gastrectomy in six patients and Devine's antral exclusion in one patient. Surgical site infection was the most common (45.5%) postoperative complication. Four patients died within one month of the surgery. Three patients who underwent gastrectomy survived for one year and one patient survived for five years. Although gastric cancer perforation usually occurs in advanced stage of the disease, curative resection should be considered as far as possible.

  16. Rare occupational cause of nasal septum perforation: Nickel exposure

    Directory of Open Access Journals (Sweden)

    Ertugrul Cagri Bolek

    2017-10-01

    Full Text Available Many etiologies are held accountable for nasal septum perforations. Topical nasal drug usage, previous surgeries, trauma, nose picking, squamous cell carcinoma, some rheumatological disorders such as granulomatosis with polyangiitis (Wegener granulomatosis, some infectious diseases such as syphilis and leprosy are among the causes of the perforations. Occupational heavy metal exposures by inhalation rarely may also cause nasal septum perforation. Here, we present a 29-year-old patient without any known diseases, who is a worker at a metallic coating and nickel-plating factory, referred for investigation of his nasal cartilage septum perforation from an otorhinolaryngology clinic. The patient questioning, physical examination and laboratory assessment about rheumatic and infectious diseases were negative. There was a metallic smell in the breath during the physical examination. The analysis showed serum nickel level at 31 μg/l and urine nickel at 18 μg/l (84.11 μg/g creatinine. Other possible serum and urine heavy metal levels were within normal ranges. Nickel exposure is usually together with other heavy metals (chromium or cadmium, it is rarely alone. Nickel ingested by inhalation usually leads to respiratory problems such as reduced olfactory acuity, ulcers, septum perforation or tumors of the nasal sinuses. This case demonstrates the importance of occupational anamnesis and awareness of diagnosis. Int J Occup Med Environ Health 2017;30(6:963–967

  17. Duodenal perforation precipitated by scrub typhus

    Directory of Open Access Journals (Sweden)

    Raghunath Rajat

    2015-01-01

    Full Text Available Scrub typhus is an acute febrile illness usually presenting with fever, myalgia, headache, and a pathognomonic eschar. Severe infection may lead to multiple organ failure and death. Gastrointestinal tract involvement in the form of gastric mucosal erosions and ulcerations owing to vasculitis resulting in gastrointestinal bleeding is common. This process may worsen a pre-existent asymptomatic peptic ulcer, causing duodenal perforation, and present as an acute abdomen requiring surgical exploration. We report the case of a patient with no previous symptoms or risk factors for a duodenal ulcer, who presented with an acute duodenal perforation, probably precipitated by scrub typhus infection.

  18. Bowel Perforation in Premature Infants with Necrotizing Enterocolitis: Risk Factors and Outcomes

    Directory of Open Access Journals (Sweden)

    Lingling Yu

    2016-01-01

    Full Text Available We aim to determine risk factors and clinical outcomes for bowel perforation in premature infants with NEC. We analyzed clinical data of 57 cases of premature infants with NEC at our NICU between January 2010 and December 2012. Based on the presence of bowel perforation, we divided these infants into two groups: perforated NEC group (n=10 and nonperforated NEC group (n=47. We compared general information, clinical characteristics, and laboratory findings between groups. The perforated NEC group, compared to the nonperforated NEC group, had significantly lesser gestational age, lower birth weight, higher prevalence of apnea, mechanical ventilation, sepsis and shock, lower blood pH, higher levels of blood glucose, abnormal WBC count and thrombocytopenia, and elevated CRP (all P<0.05. Moreover, the perforated NEC group had significantly longer durations of fasting and TPN usage, higher incidences of EUGR and cholestasis, longer duration of antibiotics, higher frequency of advanced antibiotics use, and poorer prognosis than the nonperforated NEC group (all P<0.05. Bowel perforation in premature infants with NEC was associated with multiple risk factors. Early identification of some of these risk factors in premature infants with NEC may help implement early intervention to reduce the incidence of bowel perforation and thereby improve the prognosis.

  19. Pipe drafting and design

    CERN Document Server

    Parisher, Roy A; Parisher

    2000-01-01

    Pipe designers and drafters provide thousands of piping drawings used in the layout of industrial and other facilities. The layouts must comply with safety codes, government standards, client specifications, budget, and start-up date. Pipe Drafting and Design, Second Edition provides step-by-step instructions to walk pipe designers and drafters and students in Engineering Design Graphics and Engineering Technology through the creation of piping arrangement and isometric drawings using symbols for fittings, flanges, valves, and mechanical equipment. The book is appropriate primarily for pipe

  20. Determination of the Composition and Quantity of Phthalate Ester Additives in PVC Children's Toys. Greenpeace Research Laboratories Technical Note 06/97.

    Science.gov (United States)

    Stringer, Ruth; Labounskaia, Irina; Santillo, David; Johnston, Paul; Siddorn, John; Stephenson, Angela

    Polyvinyl chloride (vinyl or PVC) is widely used in toys and other children's products. This study, conducted by Greenpeace, examined the composition and quantity of phthalate ester additives in children's PVC toys, used to give the toys added flexibility. Drawn from 17 countries, a total of 71 toys designed to be chewed by babies and young…

  1. SYNTHESIS OF ACETIC ACID FROM ETHANOL BY ELECTROOXIDATION TECHNIQUE USING Ni-Cu-PVC ELECTRODE

    Directory of Open Access Journals (Sweden)

    Riyanto Riyanto

    2017-11-01

    Full Text Available A usage of Ni-Cu-PVC electrode for the oxidation of ethanol by electrochemical technique will be reported in this paper. In this work, the effect of electrodes on the yields of acetic acid was determined. Electrode used was made of the mixtures of Ni powder, Cu powder and of polyvinyl chloride (PVC with various percentages. Electrooxidation of 0.20 M ethanol in 0.16 M KOH  (24 mL were carried out using chrono coulometry (CC at a potential of 1050 mV for 6 hours with continious stirring. Electrooxdation result obtained was analyzed using High Performance Liquid Chromatography (HPLC. The test result shows that the composition of  Ni:Cu:PVC  at 75:20:5 have higher efficiency in the electrooxidation of ethanol to acetic acid.

  2. Comparative study of three different kinds of geomembranes (PVC-P, HDPE, EPDM) used in the waterproofing of reservoirs

    International Nuclear Information System (INIS)

    Blanco Fernandez, M.; Castillo Rubi, F.; Soriano Carrillo, J.; Noval Arango, A. M.; Touze-Foltz, N.; Pargada Iglesias, L.; Rico Arnaiz, G.; Aguilar gonzalez, E.

    2014-01-01

    This work describes the long-term behaviour of three kinds of geomembranes which are constituted by plasticized poly vinyl chloride (PVC-P), high density polyethylene (HDPE) and terpolymer rubber of ethylene-propylene-dienic monomer (EPDM) used as the waterproofing system of the reservoirs Los Llanos de Mesa, San Isidro and El Golfo, respectively. Characteristics of the three original geomembranes and their behaviour along time are presented. Thicknesses, content and nature of the plasticizers ( in PVC-P), tensile properties dynamic and static puncture, foldability at low temperature, shore hardeness, tear resistance and carbon black ( in HDPE), joint strength (shear and peeling test) and microscopy, both optical and electronic scanning tests were carried out. Results obtained conclude with a long-term durability of geomembranes, independently of their macromolecular nature. These characteristics were determined by advanced analytical techniques in PVC-P samples, such as fourier Transform Infrared Spectroscopy (FTIR), Gas Chromatography (GC) and Mass Spectrometry (MS). Spectrometry (MS). (Author)

  3. Risk factors for reintervention after surgery for perforated gastroduodenal ulcer

    DEFF Research Database (Denmark)

    Hasselager, R B; Lohse, N; Duch, P

    2016-01-01

    BACKGROUND: Perforated gastroduodenal ulcer carries a high mortality rate. Need for reintervention after surgical repair is associated with worse outcome, but knowledge on risk factors for reintervention is limited. The aim was to identify prognostic risk factors for reintervention after perforated...... gastroduodenal ulcer in a nationwide cohort. METHODS: All patients treated surgically for perforated gastroduodenal ulcer in Denmark between 2003 and 2014 were included using data from the Danish Clinical Register of Emergency Surgery. Potential risk factors for reintervention were assessed, and their crude...... and adjusted associations calculated by the competing risks subdistribution hazards approach. RESULTS: A total of 4086 patients underwent surgery for perforated gastroduodenal ulcer during the study interval. Median age was 71·1 (i.q.r. 59·6-81·0) years and the overall 90-day mortality rate was 30·8 per cent...

  4. Posterior perforation of gastric ulcer: a rare surgical emergency ...

    African Journals Online (AJOL)

    BACKGROUND:Gastric ulcer perforation is a rare surgical emergency.Posterior gastric ulcer is even rarer and usually has a delayed presentation with attendant greater morbidity and mortality. AIM:To report a case of posterior perforation of gastric ulcer and review the literature. CASE REPORT:A 65yr old driver was seen in ...

  5. Structural, thermal, dielectric spectroscopic and AC impedance properties of SiC nanoparticles doped PVK/PVC blend

    Science.gov (United States)

    Alghunaim, Naziha Suliman

    2018-06-01

    Nanocomposite films based on poly (N-vinylcarbazole)/polyvinylchloride (PVK/PVC) blend doped with different concentrations of Silicon Carbide (SiC) nanoparticles have been prepared. The X-ray diffraction, Ultra violet-visible spectroscopy, thermogravimetric analysis and electrical spectroscopic has been used to characterize these nanocomposites. The X-ray analysis confirms the semi-crystalline nature of the films. The intensity of the main X-ray peak is decreased due to the interaction between the PVK/PVC and SiC. The main SiC peaks are absent due to complete dissolution of SiC in polymeric matrices. The UV-Vis spectra indicated that the band gap optical energy is affected by adding SiC nanoparticles because the charges transfer complexes between PVK/PVC with amount of SiC. The thermal stability is improved and the estimated values of ε‧ and ε″ are increased with increasing for SiC content due to the free charge carriers which in turn increase the ionic conductivity of the doped samples. The plots of tan δ with frequency are studied. A single peak from the plot between tan δ and Log (f) is appeared and shifted towards the higher frequency confirmed the presence of relaxing dipoles moment.

  6. Immobilization of ionophore and surface characterization studies of the titanium(III) ion in a PVC-membrane sensor.

    Science.gov (United States)

    Rezayi, Majid; Heng, Lee Yook; Kassim, Anuar; Ahmadzadeh, Saeid; Abdollahi, Yadollah; Jahangirian, Hossein

    2012-01-01

    Novel ionophores comprising various hydroxide and amine structures were immobilized onto poly(vinyl chloride) (PVC) matrices, and these were examined to determine Ti(III) selectivity. To predict the selectivity of Ti(III), a PVC membrane was used to investigate the binding of Ti(III) to c-methylcalix[4]resorcinarene (CMCR). The study showed that the chelating ligand, CMCR, was coordinated selectively to Ti(III) at eight coordination sites involving the oxygen atoms at the interface of the membrane/solution. The membrane was prepared, based on CMCR as an ionophore, sodium tetrakis(4-fluorophenyl) borate (NaTFPB) as a lipophilic ionic additive, and dioctylphthalate (DOP) as a plasticizer. The immobilization of the ionophore and surface characterization studies revealed that the performance of CMCR-immobilized PVC was equivalent to that of mobile ionophores in supported liquid membranes (SLMs). The strengths of the ion-ionophore (CMCR-Ti(OH)(OH(2))(5) (2+)) interactions and the role of ionophores on membranes were studied via UV-Vis, Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM) and and X-ray diffraction (XRD).

  7. Evaluation of dosimetric characteristics of graphene oxide/PVC nanocomposite for gamma radiation applications

    Energy Technology Data Exchange (ETDEWEB)

    Feizi, Shahzad; Malekie, Shahryar; Ziaie, Farhood [Nuclear Science and Technology Research Institute (NSTRI), Karaj (Iran, Islamic Republic of). Radiation Application Research School; Rahighi, Reza; Tayyebi, Ahmad [Univ. of Technology, Tehran (Iran, Islamic Republic of). Dept. of Physics

    2017-04-01

    Graphene oxide-polyvinyl chloride composite was prepared using tetrahydrofuran solvent-assisted dispersion of characterized nano flakes of graphene oxide in polymer matrix. Electrical percolation threshold of GO/PVC nanocomposite was determined via a finite element simulation method with a 2D model and compared with experimental results. A conductive cell with two silver coated walls was designed and fabricated for exploring dosimetric properties of the composite. Some characteristics of the new nanocomposite such as linearity of dose response, repeatability, sensitivity and angular dependence are investigated. According to 2D proposed method, obtained data associated to electrical conductivity of the GO/polymer composite for PVC matrix plotted in different GO weight percentages and had good compatibility (validity) with experimental data. The dose response is linear in the 17-51 mGy dose range and it can be introduced for gamma radiation dosimetry in diagnostic activities.

  8. ASSESSMENT OF SEVERITY OF PERFORATED PERITONITIS USING MODIFIED APACHE II SCORE

    Directory of Open Access Journals (Sweden)

    L. Rajeswar Reddy

    2016-06-01

    Full Text Available Acute generalised peritonitis from gastrointestinal hollow viscus perforation is a potentially life threatening condition. It is a common surgical emergency in many general surgical units in the developing countries and it is often associated with high morbidity and mortality. Grading the severity of acute peritonitis has assisted in no small way in decision making and has improved therapy in the management of severely ill patients. Empirically based risk assessment for important clinical events has been extremely useful in evaluating new therapies, in monitoring resources for effective use and improving quality of care. MATERIAL AND METHODS A prospective survey of patients with acute generalised peritonitis due to gastrointestinal perforation was carried out in general surgical wards of KIMS Hospital, Amalapuram during the period starting from July 2013-November 2016. The study population consisted of 50 consecutive patients who had laparotomy during the study period for acute peritonitis due to gastrointestinal perforation, after diagnostic conformation. RESULT AND DISCUSSION The most common cause of peritonitis in our study was perforated duodenal ulcer (31 cases, followed by appendicular perforation (7 cases, followed by stomach perforation (7 cases. Despite delay in seeking treatment, the overall mortality rate (14% was favourably comparable with other published series.

  9. Spontaneous Uterine Perforation of Pyometra Presenting as Acute Abdomen

    Directory of Open Access Journals (Sweden)

    Toshihiro Kitai

    2014-01-01

    Full Text Available Pyometra is the accumulation of pus in the uterine cavity, and spontaneous perforation of pyometra resulting in generalized diffuse peritonitis is extremely uncommon. We report a rare case of diffuse peritonitis caused by spontaneous perforation of pyometra. A 66-year-old postmenopausal woman with diffuse abdominal pain and vomiting was admitted to our institution. She had a history of mixed connective-tissue disease and had been taking steroids for 20 years. Under a diagnosis of generalized peritonitis secondary to perforation of the gastrointestinal tract or uterus, supravaginal hysterectomy and bilateral salpingo-oophorectomy were performed. Unfortunately, wound dehiscence and infection occurred during the postoperative course, which were exacerbated by her immunocompromised state. Despite intensive care and a course of antibiotics, the patient died of multiple organ failure resulting from sepsis on the 36th postoperative day. Although correct diagnosis, early intervention, and proper treatment can reduce morbidity and mortality of spontaneous perforation of pyometra, if severe infection occurs, this disease can be life threatening for immunocompromised hosts.

  10. An investigation of the damaged zone created by perforating

    International Nuclear Information System (INIS)

    Pucknell, J.K.; Behrmann, L.A.

    1991-01-01

    This paper reports on underbalance perforation flow experiments performed on reservoir and outcrop sandstones to investigate the perforation damaged zone. Cores from several different formations were perforated under reservoir conditions. After perforating, the cores were examined using CAT scans (Computer Aided tomography), thin sections and mercury porosimetry. In conjunction with these measurements, permeabilities in the damaged zone were measured using a minipermeameter and radial flow permeameter or were estimated from pore size distribution. The density and porosity of the damaged zone (at least for saturated rocks) is essentially the same as that in the undamaged rock. The damaged zone is not compacted, contrary to suggestions made in earlier work. However, the creation of this zone involves the destruction of large pores. The volume lost from these pores is replaced by microfractures created when rock grains are fractured by penetration of the shaped charge jet. This reduction in the average pore size causes a reduction in the permeability with the damaged zone. Although direct measurement of this permeability was made difficult by naturally occurring permeability variations, unambiguous measurements were obtained

  11. Costs of treating bleeding and perforated peptic ulcers in The Netherlands.

    Science.gov (United States)

    de Leest, Helena; van Dieten, Hiske; van Tulder, Maurits; Lems, Willem F; Dijkmans, Ben A C; Boers, Maarten

    2004-04-01

    Gastrointestinal toxicity of nonsteroidal antiinflammatory drugs includes perforations and bleeds. Several preventive strategies are being tested for cost-effectiveness, but little is known about the costs of the complications they are trying to prevent. We estimated the direct costs of hospital treatment of bleeding and perforated ulcers in a university hospital, from data in discharge letters and the hospital management information system. Eligible patients had been treated in the VU University Medical Center between January 1997 and August 2000 for an ulcer bleed or perforation (International Classification of Diseases code 531-4). Resource use comprised hospitalization days and diagnostic and therapeutic interventions. Insurance claim prices determined the costs from the payers' perspective. In a secondary analysis we excluded resource use that was clearly related to the treatment of comorbid illness. Fifty-three patients with a bleeding (n = 35) or perforated ulcer (n = 15) or both (n = 3) were studied, including 14 with comorbidity; 22 complications occurred in the stomach, 29 in the duodenum, one in both stomach and duodenum, and one after partial gastrectomy. A simultaneous bleed and perforation was most expensive (26,000 euro), followed by perforation (19,000 euro) and bleeding (12,000 euro). A bleed in the duodenum was more expensive than in the stomach (13,000 euro vs 10,000 euro), while the opposite was seen for perforations (13,000 euro vs 21,000 euro). Comorbidity increased costs substantially: even after correction for procedures unrelated to the ulcer complication, comorbidity more than doubled the costs of treatment. Treatment of complicated ulcers is expensive, especially in patients with comorbid conditions.

  12. Perforated Gastric Ulcer Associated with Anti-Angiogenic Therapy

    Directory of Open Access Journals (Sweden)

    Diogo Libânio

    2017-08-01

    Full Text Available Anti-angiogenic therapy with bevacizumab, an inhibitor of vascular endothelial growth factor, is commonly used in metastatic colorectal cancer and is rarely associated with gastrointestinal perforation, perforation being more frequent in the primary tumor site or at the anastomotic level. We present the case of a 64-year-old male with stage IV rectal adenocarcinoma who was on palliative chemotherapy with FOLFOX and bevacizumab. After the 4th chemotherapy cycle, our patient started fever and epigastric pain. He was hemodynamically stable, and signs of peritoneal irritation were absent. There were no alterations in the abdominal X-ray, and C-reactive protein was markedly elevated. A CT scan revealed a de novo thickness in the gastric antrum. Upper digestive endoscopy showed an ulcerated 40-mm lesion in the angulus, with a 20-mm orifice communicating with an exsudative cavity revested by the omentum. A conservative approach was decided including fasting, broad-spectrum intravenous antibiotics, and proton-pump inhibitors. Subsequent gastroduodenal series showed no contrast extravasation, allowing the resumption of oral nutrition. Esophagogastroduodenoscopy after 8 weeks showed perforation closure. Biopsies did not show neoplastic cells or Heliobacter pylori infection. Although the success in the conservative management of perforation allowing the maintenance of palliative chemotherapy (without bevacizumab, the patient died after 4 months due to liver failure. The reported case shows an uncommon endoscopic finding due to a rare complication of anti-angiogenic therapy. Additionally, it reminds clinicians that a history of gastroduodenal ulcers should be actively sought before starting anti-angiogenic treatment and that suspicion for perforation should be high in these cases.

  13. Conservative Management of Colonoscopic Perforation: A Case Report.

    Science.gov (United States)

    Parsa, Hossein; Miroliaee, Arash; Doagoo, Zafar; Sina, Saeed

    2017-07-01

    Colonoscopy is widely used for the diagnosis, treatment and a follow up of colorectal diseases. Perforation of the large bowel during elective colonoscopy is rare but serious life threatening complication. We report a 51-year-old woman who experienced recto sigmoid perforation during diagnostic colonoscopy. During 8 days of total hospitalization, she spent 3 days in ICU with gastrointestinal rest. The patient was hydrated and took intravenous antibiotics. In take-output and temperature were closely monitored. Serial abdominal examinations were performed to rule out peritonitis. After transferring to surgery ward in the day 4, liquid diet started slowly, and she was ambulated. At the day 8, she was discharged with the good clinical condition. Conservative management of the patients with early diagnosis of perforation and no signs and symptoms of peritonitis or sepsis could be the modality of choice.

  14. Primary tubercular caecal perforation: a rare clinical entity

    Directory of Open Access Journals (Sweden)

    Moses Sonia

    2010-03-01

    Full Text Available Abstract Background Intestinal tuberculosis is a common problem in endemic areas, causing considerable morbidity and mortality. An isolated primary caecal perforation of tubercular origin is exceptionally uncommon. Case presentation We report the case of a 39 year old male who presented with features of perforation peritonitis, which on laparotomy revealed a caecal perforation with a dusky appendix. A standard right hemicolectomy with ileostomy and peritoneal toileting was done. Histopathology revealed multiple transmural caseating granulomas with Langerhans-type giant cells and acid-fast bacilli, consistent with tuberculosis, present only in the caecum. Conclusions We report this extremely rare presentation of primary caecal tuberculosis to sensitize the medical fraternity to its rare occurrence, which will be of paramount importance owing to the increasing incidence of tuberculosis all over the world, especially among the developing countries.

  15. Perforated peptic ulcer in Tikur Anbessa Hospital: a review of 74 cases.

    Science.gov (United States)

    Ersumo, Tessema; W/Meskel, Yidnekachew; Kotisso, Berhanu

    2005-01-01

    Little is known on the pattern of perforated peptic ulcer in Ethiopia. To evaluate the early, outcome of management, a five-year retrospective analysis of 74 operated cases of perforated peptic ulcer was undertaken. Perforated peptic ulcer accounted for 3.4% of the adult emergency surgical procedures. The mean age was 32.6 years, with a male to female ratio of 7.2 to 1.0. Fifty-six percent of the cases were unmarried. In nearly 22.0% of the patients, no previous history of peptic ulcer disease was documented. Delay in diagnosis was noted in 95% of the cases. Most patients had duodenal ulcer perforation, and about 78% had purulent peritonitis at laparotomy. Fourteen died in hospital. Early presentation of patients to surgical care facilities may reduce morbidity and mortality in cases of peptic ulcer perforation.

  16. Heat pipes and use of heat pipes in furnace exhaust

    Science.gov (United States)

    Polcyn, Adam D.

    2010-12-28

    An array of a plurality of heat pipe are mounted in spaced relationship to one another with the hot end of the heat pipes in a heated environment, e.g. the exhaust flue of a furnace, and the cold end outside the furnace. Heat conversion equipment is connected to the cold end of the heat pipes.

  17. Drill pipe bridge plug

    International Nuclear Information System (INIS)

    Winslow, D.W.; Brisco, D.P.

    1991-01-01

    This patent describes a method of stopping flow of fluid up through a pipe bore of a pipe string in a well. It comprises: lowering a bridge plug apparatus on a work string into the pipe string to a position where the pipe bore is to be closed; communicating the pipe bore below a packer of the bridge plug apparatus through the bridge plug apparatus with a low pressure zone above the packer to permit the fluid to flow up through the bridge plug apparatus; engaging the bridge plug apparatus with an internal upset of the pipe string; while the fluid is flowing up through the bridge plug apparatus, pulling upward on the work string and the bridge plug apparatus and thereby sealing the packer against the pipe bore; isolating the pipe bore below the packer from the low pressure zone above the packer and thereby stopping flow of the fluid up through the pipe bore; disconnecting the work string from the bridge plug apparatus; and maintaining the bridge plug apparatus in engagement with the internal upset and sealed against the pipe bore due to an upward pressure differential applied to the bridge plug apparatus by the fluid contained therebelow

  18. Giant trochanteric pressure sore: Use of a pedicled chimeric perforator flap for cover

    Directory of Open Access Journals (Sweden)

    Mehrotra Sandeep

    2009-01-01

    Full Text Available Pressure sores are increasing in frequency commensurate with an ageing population with multi-system disorders and trauma. Numerous classic options are described for providing stable wound cover. With the burgeoning knowledge on perforator anatomy, recent approaches focus on the use of perforator-based flaps in bedsore surgery. A giant neglected trochanteric pressure sore in a paraplegic is presented. Since conventional options of reconstruction appeared remote, the massive ulcer was successfully managed by a chimeric perforator-based flap. The combined muscle and fasciocutaneous flaps were raised as separate paddles based on the anterolateral thigh perforator branches and provided stable cover without complications. Perforators allow versatility in managing complex wounds without compromising on established principles.

  19. Molecular Signatures for the PVC Clade (Planctomycetes, Verrucomicrobia, Chlamydiae and Lentisphaerae of Bacteria Provide Insights into their Evolutionary Relationships

    Directory of Open Access Journals (Sweden)

    Radhey S. Gupta

    2012-09-01

    Full Text Available The PVC superphylum is an amalgamation of species from the phyla Planctomycetes, Verrucomicrobia and Chlamydiae, along with the Lentisphaerae, Poribacteria and two other candidate divisions. The diverse species of this superphylum lack any significant marker that differentiates them from other bacteria. Recently, genome sequences for 37 species covering all of the main PVC groups of bacteria have become available. We have used these sequences to construct a phylogenetic tree based upon concatenated sequences for 16 proteins and identify molecular signatures in protein sequences that are specific for the species from these phyla or those providing molecular links among them. Of the useful molecular markers identified in the present work, 6 conserved signature indels (CSIs in the proteins Cyt c oxidase, UvrD helicase, urease and a helicase-domain containing protein are specific for the species from the Verrucomicrobia phylum; three other CSIs in an ABC transporter protein, cobyrinic acid ac-diamide synthase and SpoVG protein are specific for the Planctomycetes species. Additionally, a 3 aa insert in the RpoB protein is uniquely present in all sequenced Chlamydiae, Verrucomicrobia and Lentisphaerae species, providing evidence for the shared ancestry of the species from these three phyla. Lastly, we have also identified a conserved protein of unknown function that is exclusively found in all sequenced species from the phyla Chlamydiae, Verrucomicrobia, Lentisphaerae and Planctomycetes suggesting a specific linkage among them. The absence of this protein in Poribacteria, which branches separately from other members of the PVC clade, indicates that it is not specifically related to the PVC clade of bacteria. The molecular markers described here in addition to clarifying the evolutionary relationships among the PVC clade of bacteria also provide novel tools for their identification and for genetic and biochemical studies on these organisms.

  20. Insulated pipe clamp design

    International Nuclear Information System (INIS)

    Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

    1980-01-01

    Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. 5 refs

  1. Miniature Heat Pipes

    Science.gov (United States)

    1997-01-01

    Small Business Innovation Research contracts from Goddard Space Flight Center to Thermacore Inc. have fostered the company work on devices tagged "heat pipes" for space application. To control the extreme temperature ranges in space, heat pipes are important to spacecraft. The problem was to maintain an 8-watt central processing unit (CPU) at less than 90 C in a notebook computer using no power, with very little space available and without using forced convection. Thermacore's answer was in the design of a powder metal wick that transfers CPU heat from a tightly confined spot to an area near available air flow. The heat pipe technology permits a notebook computer to be operated in any position without loss of performance. Miniature heat pipe technology has successfully been applied, such as in Pentium Processor notebook computers. The company expects its heat pipes to accommodate desktop computers as well. Cellular phones, camcorders, and other hand-held electronics are forsible applications for heat pipes.

  2. Rare occupational cause of nasal septum perforation: Nickel exposure.

    Science.gov (United States)

    Bolek, Ertugrul Cagri; Erden, Abdulsamet; Kulekci, Cagri; Kalyoncu, Umut; Karadag, Omer

    2017-10-06

    Many etiologies are held accountable for nasal septum perforations. Topical nasal drug usage, previous surgeries, trauma, nose picking, squamous cell carcinoma, some rheumatological disorders such as granulomatosis with polyangiitis (Wegener granulomatosis), some infectious diseases such as syphilis and leprosy are among the causes of the perforations. Occupational heavy metal exposures by inhalation rarely may also cause nasal septum perforation. Here, we present a 29-year-old patient without any known diseases, who is a worker at a metallic coating and nickel-plating factory, referred for investigation of his nasal cartilage septum perforation from an otorhinolaryngology clinic. The patient questioning, physical examination and laboratory assessment about rheumatic and infectious diseases were negative. There was a metallic smell in the breath during the physical examination. The analysis showed serum nickel level at 31 μg/l and urine nickel at 18 μg/l (84.11 μg/g creatinine). Other possible serum and urine heavy metal levels were within normal ranges. Nickel exposure is usually together with other heavy metals (chromium or cadmium), it is rarely alone. Nickel ingested by inhalation usually leads to respiratory problems such as reduced olfactory acuity, ulcers, septum perforation or tumors of the nasal sinuses. This case demonstrates the importance of occupational anamnesis and awareness of diagnosis. Int J Occup Med Environ Health 2017;30(6):963-967. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  3. Diagnosing perforated appendicitis in pediatric patients: a new model.

    Science.gov (United States)

    van den Bogaard, Veerle A B; Euser, Sjoerd M; van der Ploeg, Tjeerd; de Korte, Niels; Sanders, Dave G M; de Winter, Derek; Vergroesen, Diederik; van Groningen, Krijn; de Winter, Peter

    2016-03-01

    Studies have investigated sensitivity and specificity of symptoms and tests for diagnosing appendicitis in children. Less is known with regard to the predictive value of these symptoms and tests with respect to the severity of appendicitis. The aim of this study was to determine the predictive value of patient's characteristics and tests for discriminating between perforated and nonperforated appendicitis in children. Pediatric patients who underwent an appendectomy at Spaarne Hospital Hoofddorp, the Netherlands, between January 1, 2009 and December 31, 2013, were included. Baseline patient's characteristics, history, physical examination, laboratory data and results of ultrasounds were collected. Univariate and multivariate logistic regressions were used to determine predictors of perforation. In total, 375 patients were included in this study of which 97 children (25.9%) had significant signs of perforation. Univariate analysis showed that age, duration of complaints, temperature, vomiting, CRP, WBC, different findings on ultrasound and the diameter of the appendix were good predictors of a perforated appendicitis. The final multivariate prediction model included temperature, CRP, clearly visible appendix and free fluids on ultrasound and diameter of the appendix and resulted in an area under the curve (AUC) of 0.91 showing sensitivity and specificity of respectively 85.2% and 81.2%. This prediction model can be used for identification of 'high-risk' children for a perforated appendicitis and might be helpful to prevent complications and longer hospitalization by bringing these children to theater earlier. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Using perforators as recipient vessels (supermicrosurgery) for free flap reconstruction of the knee region.

    Science.gov (United States)

    Hong, Joon Pio; Koshima, Isao

    2010-03-01

    The purpose of this article is to evaluate the feasibility of a perforator as a recipient vessel to reconstruct soft tissue defects of the knee region.From December of 2006 to August of 2008, total of 25 patients underwent reconstructive procedure using either an anterolateral thigh or an upper medial thigh perforator flap. The flaps were anastomosed in a perforator to perforator manner using supermicrosurgery technique.Minimum of 3 perforators were traced around the knee defect. All flaps survived attached to a recipient perforator with artery diameter ranging from 0.4 to 0.9 mm and accompanying veins ranging from 0.4 to 1.2 mm. This approach allowed reduction in time for pedicle and recipient vessel dissection and minimized the trauma involved during isolation of the vessels.Using the perforator as recipient vessel allows an increase in selection for choice of recipient. By using a perforator as recipient, less time is consumed to secure the vessel, does not need long pedicles for flap, is not bound by the condition of major arteries, and minimizes any risk for major vessel injury while having acceptable flap survival.

  5. Detecting failed elements on phased array ultrasound transducers using the Edinburgh Pipe Phantom

    Science.gov (United States)

    Inglis, Scott; Pye, Stephen D

    2016-01-01

    Aims Imaging faults with ultrasound transducers are common. Failed elements on linear and curvilinear array transducers can usually be detected with a simple image uniformity or ‘paperclip’ test. However, this method is less effective for phased array transducers, commonly used in cardiac imaging. The aim of this study was to assess whether the presence of failed elements could be detected through measurement of the resolution integral (R) using the Edinburgh Pipe Phantom. Methods A 128-element paediatric phased array transducer was studied. Failed elements were simulated using layered polyvinyl chloride (PVC) tape as an attenuator and measurements of resolution integral were carried out for several widths of attenuator. Results All widths of attenuator greater than 0.5 mm resulted in a significant reduction in resolution integral and low contrast penetration measurements compared to baseline (p tests to detect failed elements on phased array transducers. Particularly encouraging is the result for low contrast penetration as this is a quick and simple measurement to make and can be performed with many different test objects, thus enabling ‘in-the-field’ checks. PMID:27482276

  6. Complicações determinadas por placas de cloreto de polivinila (PVC na estabilização da porção cervical caudal da coluna vertebral de cães Complications determined by polyvinylchloride (PVC plates in the stabilization of caudal cervical vertebral column of dogs

    Directory of Open Access Journals (Sweden)

    Mônica Vicky Bahr Arias

    2003-12-01

    Full Text Available Em 10 cães com peso médio de 14,6kg, as vértebras cervicais 5 e 6 foram cirurgicamente desestabilizadas através da secção do disco intervertebral e, em seguida, estabilizadas com placas ortopédicas confeccionadas com PVC de 2mm de espessura, para após 180 dias, proceder-se ao estudo histológico do tecido ósseo e conjuntivo circunvizinho. Constatou-se que o PVC causou alterações ósseas que podem ter favorecido o afrouxamento dos parafusos e a falha do implante. O material induziu ainda à formação de granuloma de corpo estranho e a reações inflamatórias locais que podem ter causado degradação do material implantado. Assim, placas de PVC, apesar de proporcionarem estabilidade e alinhamento da coluna vertebral, não satisfazem a maioria das propriedades necessárias a um biomaterial, não sendo recomendadaa a sua utilização em ortopedia veterinária.In ten dogs with an average mean weight of 14,6 kg, the cervical vertebra 5 and 6 were destabilized and fixed with plates of 2mm of thickness. The purpose of this work was to verify the effect of orthopedic PVC plates on the internal stabilization of the caudal cervical spine of dogs by studying the occurrence of alterations in the bone tissue and fibrous tissue adjacent to the plate after 180 days of permanence of the material in the dogs' organism. PVC causes progressive bone alterations, which, in the long term, could promote the loosening of the screws and failure of the implant. It also induces the formation of foreign body granuloma and inflammatory reactions which could cause degradation of the implant. Thus, PVC plates do not satisfy the majority of properties required of a biomaterial, its use not being recommended in veterinary orthopedics.

  7. Riser pipe elevator

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, W.; Jimenez, A.F.

    1987-09-08

    This patent describes a method for storing and retrieving a riser pipe, comprising the steps of: providing an upright annular magazine comprised of an inside annular wall and an outside annular wall, the magazine having an open top; storing the riser pipe in a substantially vertically oriented position within the annular magazine; and moving the riser pipe upwardly through the open top of the annular magazine at an angle to the vertical along at least a portion of the length of the riser pipe.

  8. The Effect of Zn-Al-Hydrotalcites Composited with Calcium Stearate and β-Diketone on the Thermal Stability of PVC

    Directory of Open Access Journals (Sweden)

    Runjuan Wen

    2011-03-01

    Full Text Available A clean-route synthesis of Zn-Al-hydrotalcites (Zn-Al-LDHs using zinc oxide and sodium aluminate solution has been developed. The as-obtained materials were characterized by X-ray diffraction (XRD, Fourier transform infrared spectroscopy (FT-IR, and scanning electron microscopy (SEM. The effects of metal ions at different molar ratios on the performance of hydrotalcites were discussed. The results showed that the Zn-Al-hydrotalcites can be successfully synthesized at three different Zn/Al ratios of 3:1, 2:1 and 1:1. Thermal aging tests of polyvinyl chloride (PVC mixed with Zn-Al-LDHs, calcium stearate (CaSt2 and β-diketone were carried out in a thermal aging test box by observing the color change. The results showed that Zn-Al-LDHs can not only enhance the stability of PVC significantly due to the improved capacity of HCl-adsorption but also increase the initial stability and ensure good-initial coloring due to the presence of the Zn element. The effects of various amounts of Zn-Al-LDHs, CaSt2 and β-diketone on the thermal stability of PVC were discussed. The optimum composition was determined to be 0.1 g Zn-Al-LDHs, 0.15 g CaSt2 and 0.25 g β-diketone in 5 g PVC.

  9. All-Solid-State, PVC Membrane, and Carbon Paste Ion-Selective Electrodes for Determination of Donepezil Hydrochloride in Pharmaceutical Formulation.

    Science.gov (United States)

    Khamees, Nesreen; Mohamed, Tagreed Abdel-Fattah; Derar, Abeer Rashad; Aziz, Azza

    2017-09-01

    All-solid-state, polyvinyl chloride (PVC) membrane, and carbon paste potentiometric ion-selective electrodes (ISEs) were proposed for the determination of donepezil hydrochloride (DON) in the drug substance and a pharmaceutical formulation. The potentiometric response toward DON was based on the existence of donepezil-tetraphenyl borate (DON-TPB) in a PVC membrane or a carbon paste in the presence of dioctylphthalate. In contrast, the solid-state electrode was prepared by direct incorporation of DON-TPB into a commercial nail varnish without external additives. The electrodes exhibited Nernstian slopes of 55.0, 57.0, and 53.0 mV/decade over the concentration ranges of 1 × 10-5 to 1 × 10-3, 1 × 10-4 to 10-2, and 1 × 10-4 to 5 × 10-3 for the solid-state, PVC membrane, and carbon paste electrodes, respectively. The response of the electrodes is independent of pH in the range of 2-≤8. The electrodes showed good selectivity for DON with respect to a number of inorganic cations and amino acids. The electrodes were used for the determination of DON in pure solution and in pharmaceutical tablets with high accuracy (±2%) and precision (RSD ≤2%). The solid-state electrode is simple, economical, and rapid when compared to the PVC membrane and carbon paste electrodes.

  10. Elastic-Plastic Behaviour of Ultrasonic Assisted Compression of Polyvinyl Chloride (PVC) Foam

    Science.gov (United States)

    Muhalim, N. A. D.; Hassan, M. Z.; Daud, Y.

    2018-04-01

    The present study aims to investigate the elastic-plastic behaviour of ultrasonic assisted compression of PVC closed-cell foam. A series of static and ultrasonic compression test of PVC closed-cell foam were conducted at a constant cross head speed of 30 mm/min on dry surface condition. For quasi-static test, specimen was compressed between two rigid platens using universal testing machine. In order to evaluate the specimen behavior under ultrasonic condition, specimen was placed between a specifically design double-slotted block horn and rigid platen. The horn was designed and fabricated prior to the test as a medium to transmit the ultrasonic vibration from the ultrasonic transducer to the working specimen. It was tuned to a frequency of 19.89 kHz in longitudinal mode and provided an average oscillation amplitude at 6 µm on the uppermost surface. Following, the characteristics of stress-strain curves for quasi-static and ultrasonic compression tests were analyzed. It was found that the compressive stress was significantly reduced at the onset of superimposed ultrasonic vibration during plastic deformation.

  11. Typhoid ileal perforation: a 13-year experience

    Directory of Open Access Journals (Sweden)

    Poras Chaudhary

    2015-07-01

    Full Text Available Typhoid fever is endemic in many developing countries with a high rate of complications. Aim of this study is to analyse epidemiological features, clinical presentations, complications and therapeutic outcomes of enteric perforation peritonitis diagnosed and treated in our hospital. Records of total number of 646 patients, who presented with perforation peritonitis due to enteric fever in the surgical emergency unit of Dr Ram Manohar Lohia hospital, New Delhi between January 2001 and December 2013, were reviewed retrospectively. Descriptive statistics was used to analyze the data. Out of 646 patients, 62 (9.59% presented in shock. Stomal, peristomal, local and systemic complications were high in these patients. Primary closure was done in 212 (33.12 patients, primary ileostomy was created in 410 (64.06 patients, and resection and anastomosis was done in 24 (3.75 patients. Thirteen patients (2.01% died of typhoid intestinal perforation. To prevent complications of typhoid fever, in addition to control sanitation, it is also important to control quackery and malpractices. Awareness and education about the disease, its nature and complications will also be of great help.

  12. Charge Transfer Resistance and Differential Capacity of the Plasticized PVC Membrane/Water Interface

    Czech Academy of Sciences Publication Activity Database

    Langmaier, Jan; Stejskalová, Květoslava; Samec, Zdeněk

    2002-01-01

    Roč. 521, 1/2 (2002), s. 81-86 ISSN 0022-0728 R&D Projects: GA AV ČR IAA4040902 Institutional research plan: CEZ:AV0Z4040901 Keywords : impedance * PVC plasticized membrane * ion transfer kinetics Subject RIV: CG - Electrochemistry Impact factor: 2.027, year: 2002

  13. Influence of delays on perforation risk in adults with acute appendicitis.

    LENUS (Irish Health Repository)

    Kearney, D

    2012-02-03

    PURPOSE: This study analyzed whether prehospital or in-hospital delay was the more significant influence on perforation rates for acute appendicitis and whether any clinical feature designated patients requiring higher surgical priority. METHODS: A retrospective analysis was conducted over one year at a tertiary referral hospital without a dedicated emergency surgical theater. Admission notes, theater logbook, and the Hospital Inpatient Enquiry system were reviewed to identify the characteristics and clinical course of patients aged greater than 16 years who were operated upon for histologically confirmed acute appendicitis. RESULTS: One hundred and fifteen patients were studied. The overall perforation rate was 17 percent. The mean duration of symptoms prior to hospital presentation was 38.1 hours with the mean in-hospital waiting time prior to operation being 23.4 hours. Although body temperature on presentation was significantly greater in patients found to have perforated appendicitis (P < 0.05), only patient heart rate at presentation and overall duration of symptoms, but not in-hospital waiting time, independently predicted perforation by stepwise linear regression modeling. CONCLUSION: In-hospital delay was not an independent predictor of perforation in adults with acute appendicitis although delays may contribute if patients are left to wait unduly. Tachycardia at presentation may be a quantifiable feature of those more likely to have perforation and who should be given higher surgical priority.

  14. Roles of ionic strength and biofilm roughness on adhesion kinetics of Escherichia coli onto groundwater biofilm grown on PVC surfaces

    Science.gov (United States)

    Janjaroen, Dao; Ling, Fangqiong; Monroy, Guillermo; Derlon, Nicolas; Mogenroth, Eberhard; Boppart, Stephen A.; Liu, Wen-Tso; Nguyen, Thanh H.

    2013-01-01

    Mechanisms of Escherichia coli attachment on biofilms grown on PVC coupons were investigated. Biofilms were grown in CDC reactors using groundwater as feed solution over a period up to 27 weeks. Biofilm physical structure was characterized at the micro- and meso-scales using Scanning Electron Microscopy (SEM) and Optical Coherence Tomography (OCT), respectively. Microbial community diversity was analyzed with Terminal Restricted Fragment Length Polymorphism (T-RFLP). Both physical structure and microbial community diversity of the biofilms were shown to be changing from 2 weeks to 14 weeks, and became relatively stable after 16 weeks. A parallel plate flow chamber coupled with an inverted fluorescent microscope was also used to monitor the attachment of fluorescent microspheres and E. coli on clean PVC surfaces and biofilms grown on PVC surfaces for different ages. Two mechanisms of E. coli attachment were identified. The adhesion rate coefficients (kd) of E. coli on nascent PVC surfaces and 2-week biofilms increased with ionic strength. However, after biofilms grew for 8 weeks, the adhesion was found to be independent of solution chemistry. Instead, a positive correlation between kd and biofilm roughness as determined by OCT was obtained, indicating that the physical structure of biofilms could play an important role in facilitating the adhesion of E. coli cells. PMID:23497979

  15. [Reconstruction of ankle and foot with combination of free perforator flaps and skin graft].

    Science.gov (United States)

    Yin, Lu; Gong, Ketong; Yin, Zhonggang; Zhang, Bo; Xu, Jianhua

    2017-03-01

    To evaluate the clinical outcomes of free perforator flaps combined with skin graft for reconstruction of ankle and foot soft tissue defects. Between June 2014 and October 2015, 20 cases of ankle and foot soft tissue defects were treated. There were 16 males and 4 females, aged from 19 to 61 years (mean, 43.3 years). Injury was caused by traffic accident in 7 cases, by crashing in 9 cases, and machine twist in 4 cases. The locations were the ankle in 6 cases, the heel in 3 cases, the dorsum pedis in 4 cases, and the plantar forefoot in 7 cases of avulsion injury after toes amputation. The size of wound ranged from 15 cm×10 cm to 27 cm×18 cm. The time from injury to treatment was from 11 to 52 days (mean, 27 days). The anterolateral thigh perforator flap was used in 11 cases, thoracodorsal antery perforator flap in 3 cases, medial sural artery perforator flap in 4 cases, deep inferior epigastric perforator flap in 1 case, and anteromedial thigh perforator flap in 1 case, including 5 chimeric perforator flaps, 5 polyfoliate perforator flaps, 3 flow-through perforator flaps, and 3 conjoined perforator flaps. The size of the perforator flap ranged from 10.0 cm×6.5 cm to 36.0 cm×8.0 cm, the size of skin graft from 5 cm×3 cm to 18 cm×12 cm. Venous crisis occurred in 2 flaps which survived after symptomatic treatment; 18 flaps survived successfully and skin grafting healed well. The follow-up time ranged 4-18 months (mean, 8.3 months). The flaps had good appearance, texture and color, without infection. The patients could walk normally and do daily activities. Only linear scars were observed at the donor sites. Free perforator flap can be used to reconstruct defects in the ankle and foot, especially in the weight-bearing area of the plantar forefoot. A combination of free perforator flap and skin graft is ideal in reconstruction of great soft tissue defects in the ankle and foot.

  16. Application of electrostatic separation to the recycling of plastic wastes: separation of PVC, PET, and ABS.

    Science.gov (United States)

    Park, Chul-Hyun; Jeon, Ho-Seok; Yu, Hyo-Shin; Han, Oh-Hyung; Park, Jai-Koo

    2008-01-01

    Plastics are widely used in everyday life as a useful material, and thus their consumption is growing at a rate of about 5% per year in Korea. However, the constant generation of plastic wastes and their disposal generates environmental problems along with economic loss. In particular, mixed waste plastics are difficult to recycle because of their inferior characteristics. A laboratory-scale triboelectrostatic separator unit has been designed and assembled for this study. On the basis of the control of electrostatic charge, the separation of three kinds of mixed plastics, polyvinyl chloride (PVC), poly(ethylene terephthalate) (PET), and acrylonitrile-butadiene-styrene (ABS), in a range of similar gravities has been performed through a two-stage separation process. Polypropylene (PP) and high-impact polystyrene (HIPS) were found to be the most effective materials for a tribo-charger in the separation of PVC, PET, and ABS. The charge-to-mass ratio (nC/g) of plastics increased with increasing air velocity in the tribo charger. In the first stage, using the PP cyclone charger, the separation efficiency of particles considerably depended on the air velocity (10 m/s), the relative humidity ( 20 kV), and the splitter position (+2 cm from the center) in the triboelelctrostatic separator unit. At this time, a PVC grade of 99.40% and a recovery of 98.10% have successfully been achieved. In the second stage, using the HIPS cyclone charger, a PET grade of 97.80% and a recovery of 95.12% could be obtained under conditions of 10 m/s, over 25 kV, a central splitter position, and less than 40% relative humidity. In order to obtain 99.9% PVC grade and 99.3% PET grade, their recoveries should be sacrificed by 20.9% and 27%, respectively, with moving the splitter from the center to a (+)6 cm position.

  17. Perforation in a patient with stercoral colitis and diverticulosis: who did it?

    Directory of Open Access Journals (Sweden)

    Vijaya R. Bhatt

    2014-02-01

    Full Text Available Stercoral colitis with perforation of the colon is an uncommon, yet life-threatening cause of the acute abdomen. No one defining symptom exists for stercoral colitis; it may present asymptomatically or with vague symptoms. Diagnostic delay may result in perforation of the colon resulting in complications, even death. Moreover, stercoral perforation of the colon can also present with localized left lower quadrant abdominal pain masquerading as diverticulitis. Diverticular diseases and stercoral colitis share similar pathophysiology; furthermore, they may coexist, further complicating the diagnostic dilemma. The ability to decide the cause of perforation in a patient with both stercoral colitis and diverticulosis has not been discussed. We, therefore, report this case of stercoral perforation in a patient with diverticulosis and include a discussion of the epidemiology, clinical presentation, and a review of helpful diagnostic clues for a rapid differentiation to allow for accurate diagnosis and treatment.

  18. [An Analysis of Perforated Gastric Cancer with Acute Peritonitis in Our Hospital].

    Science.gov (United States)

    Adachi, Shinichi; Endo, Shunji; Chinen, Yoshinao; Itakura, Hiroaki; Takayama, Hirotoshi; Tsuda, Yujiro; Ueda, Masami; Nakashima, Shinsuke; Ohta, Katsuya; Ikenaga, Masakazu; Yamada, Terumasa

    2018-01-01

    Perforated gastric cancer is relatively rare and the incidence is reported about 1% of all the cases of gastric cancer. We retrospectively analyzed the clinical data of the consecutive 12 patients with perforated gastric cancer who underwent operation in our hospital between January 2005 and December 2016. There were 5 men and 7 women, with an average age of 65.8 years old(34-87). Perforated gastric cancer occurred in the region U(1 cases), M(6 cases), L(5 cases). There were 11 cases with distant metastasis. We could successfully diagnosed as perforated gastric cancer in 8 cases before emergency operation. Gastrectomy was performed in 5 cases. However, the curative resection was performed only 1 case. Prognosis of perforated gastric cancer is poor. We considered as an appropriate two-step surgical strategy that the first step of surgery is an acute peritonitis treatment followed by radical gastrectomy with lymphadenectomy.

  19. Preoperative CT angiography reduces surgery time in perforator flap reconstruction

    NARCIS (Netherlands)

    Smit, Jeroen M.; Dimopoulou, Angeliki; Liss, Anders G.; Zeebregts, Clark J.; Kildal, Morten; Whitaker, Iain S.; Magnusson, Anders; Acosta, Rafael

    The use of perforator flaps in breast reconstructions has increased considerably in the past decade. A disadvantage of the perforator flap is difficult dissection, which results in a longer procedure. During spring 2006, we introduced CT angiography (CTA) as part of the diagnostic work-up in

  20. Safety and effectiveness evaluation of a domestic peritoneal dialysis fluid packed in non-PVC bags: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Zhou, Jianhui; Cao, Xueying; Lin, Hongli; Ni, Zhaohui; He, Yani; Chen, Menghua; Zheng, Hongguang; Chen, Xiangmei

    2015-12-29

    Peritoneal dialysis is an important type of renal replacement therapy for uremic patients. In peritoneal dialysis, fluids fill in and flow out of the abdominal cavity three to five times per day. Usually, the fluid is packed in a polyvinyl chloride (PVC) bag. Safety concerns have arisen over di-(2-ethylhexyl) phthalate, which is essential in the formation of PVC materials. In 2011, the National Development and Reform Commission of China released a catalog of industrial structural adjustments, mandating the elimination of PVC bags for intravenous infusion and food containers. Although bags for peritoneal dialysis fluid were not included in the elimination list, several manufacturers began to develop new materials for fluid bags. HUAREN peritoneal dialysis fluid consists of the same electrolytes and buffer agent as in Baxter fluid, but is packed in bags that do not contain PVC. This multicenter randomized controlled trial was designed to compare peritoneal dialysis fluid packed in non-PVC-containing and PVC-containing bags. Further, the study sought to determine the proper dose of peritoneal dialysis fluid and the actual survival rates of Chinese patients undergoing peritoneal dialysis. The study participants are adults undergoing continuous ambulatory peritoneal dialysis for 30 days to 6 months. All eligible patients are randomized (1:1) to peritoneal dialysis with Baxter and HUAREN dialysis fluids (initial dose, 6 l/day), with dosages adjusted according to a unified protocol. The primary outcomes are the 1-, 2-, 3-, 4-, and 5-year overall survival rates. Secondary outcome measures include technique survival rates, reductions in estimated glomerular filtration rate, nutritional status, quality of life, cardiovascular events, medical costs and drop-out rates. Safety outcome measures include adverse events, changes in vital signs and laboratory parameters, peritonitis, allergies, and quality of products. This study is the first to evaluate the long-term safety and