  1. Percutaneous locking plates for fractures of the distal tibia: our experience and a review of the literature.

    Science.gov (United States)

    Ahmad, Mudussar Abrar; Sivaraman, Alagappan; Zia, Ahmed; Rai, Amarjit; Patel, Amratlal D

    2012-02-01

    Distal tibial metaphyseal fractures pose many complexities. This study assessed the outcomes of distal tibial fractures treated with medial locking plates. Eighteen patients were selected based on the fracture pattern and classified using the AO classification and stabilized with an AO medial tibial locking plate. Time to fracture union, complications, and outcomes were assessed with the American Orthopedic Foot and Ankle Society Ankle score at 12 months. Sixteen of the 18 patients achieved fracture union, with 1 patient lost to follow-up. Twelve fractures united within 24 weeks, with an average union time of 23.1 weeks. Three delayed unions, two at 28 weeks and one at 56 weeks. The average time to union was 32 weeks in the smokers and 15.3 weeks in the nonsmokers. Five of the 18 patients (27%) developed complications. One superficial wound infection, and one chronic wound infection, resulting in nonunion at 56 weeks, requiring revision. Two patients required plate removal, one after sustaining an open fracture at the proximal end of the plate 6 months after surgery (postfracture union)and the other for painful hardware. One patient had implant failure of three proximal diaphyseal locking screws at the screwhead/neck junction, but successful fracture union. The average American Orthopedic Foot and Ankle Society ankle score was 88.8 overall, and 92.1 in fractures that united within 24 weeks. Distal tibial locking plates have high fracture union rates, minimum soft tissue complications, and good functional outcomes. The literature shows similar fracture union and complication rates in locking and nonlocking plates. Copyright © 2012 by Lippincott Williams & Wilkins

  2. [Case-control study on minimally invasive percutaneous locking compression plate internal fixation for the treatment of type II and III pilon fractures].

    Science.gov (United States)

    Zhang, Zhi-Da; Ye, Xiu-Yi; Shang, Li-Yong; Xu, Rong-Ming; Zhu, Yan-Zhao

    2011-12-01

    To explore the clinical efficacy of delayed open reduction and internal fixation with minimally invasive percutaneous locking compression plate for the treatment of type II and III Pilon fractures. From January 2007 to September 2009, 32 patients with type II and III Pilon fractures were treated with open reduction and anatomic plate fixation (AP group) and minimally invasive percutaneous locking compression plate osteosynthesis (LCP group). There were 11 males and 6 females in AP group, with an average age of (37.4 +/- 13.3) years (ranged, 19 to 55 years). And there were 10 males and 5 females in LCP group, with an average age of (34.6 +/- 11.3) years(ranged, 21 to 56 years). The operating time, fracture healing time, aligned angulation and ankle function were compared between the two groups. All the patients were followed up, and the during ranged from 12 to 25 months, with a mean of (15.0 +/- 1.7) months. The average operation time was (76.5 +/- 8.3) min for AP group and (58.3 +/- 3.4) min for LCP group; the average time of fracture healing was (20.5 +/- 0.4) weeks for AP group and (15.7 +/- 0.2) weeks for LCP group; the total angulation between anterior posterior film and lateral film was averaged (6.6 +/- 0.5) degrees for AP group and (3.6 +/- 0.2) degrees for LCP group. As to above index, the results of LCP group were better than those of AP group (P ankle joint, the results of LCP group were better than those of AP group in ankle joint pain, wakling and ankle joint function (P fracture with less invasion, faster bone union, more stabilized fixation, quicker recovery of ankle function and fewer complications, which is more advantaged for type II and III Pilon fractures.

  3. PWR integral tie plate and locking mechanism

    International Nuclear Information System (INIS)

    Flora, B.S.; Osborne, J.L.

    1980-01-01

    A locking mechanism for securing an upper tie plate to the tie rods of a nuclear fuel bundle is described. The mechanism includes an upper tie plate assembly and locking sleeves fixed to the ends of the tie rods. The tie plate is part of the upper tie plate assembly and is secured to the fuel bundle by securing the entire upper tie plate assembly to the locking sleeves fixed to the tie rods. The assembly includes, in addition to the tie plate, locking nuts for engaging the locking sleeves, retaining sleeves to operably connect the locking nuts to the assembly, a spring biased reaction plate to restrain the locking nuts in the locked position and a means to facilitate the removal of the entire assembly as a unit from the fuel bundle

  4. [Locked plating with minimally invasive percutaneous plate osteosynthesis versus intramedullary nailing of distal extra-articular tibial fracture: a retrospective study].

    Science.gov (United States)

    Yao, Qi; Ni, Jie; Peng, Li-bin; Yu, Da-xin; Yuan, Xiao-ming

    2013-12-17

    To compare the efficacies of minimally invasive plate osteosynthesis (MIPPO) and interlocking intramedullary nailing (IMN) in the treatment of extra-articular fractures of distal tibia. Retrospective reviews were conducted for 126 patients with extra-articular distal tibia fractures. Treatment was either MIPPO (n = 61) or IMN (n = 65). The outcomes were assessed by comparing operating duration, time to union, the last follow-up American Orthopedic Foot and Ankle Society (AOFAS) score and complication rate. The average follow-up period was 23.7 (12-53) months. In the minimally invasive plate osteosynthesis group, there were deep infections (n = 2), superficial infections (n = 5), delayed union (n = 2), malunion (n = 2) and knee joint pain (n = 10) were observed. In addition, the average operating duration (85.9 ± 18.9 min), average time to union (17.3 ± 3.8 weeks) and average AOFAS (83.2 ± 11.9) were analyzed. In the interlocking intramedullary nailing group, there were delayed union (n = 3), malunion (n = 12) and knee joint pain (n = 22). And the average operating duration (83.3 ± 15.7 min), average time to union (16.5 ± 3.1 weeks) and average AOFAS (84.9 ± 12.0) were analyzed. No statistical significance existed in operating duration, time to union and the last follow-up AOFAS between two groups (P > 0.05). However, the rates of malformation and knee joint pain were higher in the intramedullary nail group than those in the plate group. And the difference was statistically significant (P = 0.015, P = 0.025). Both MIPPO and IMN are effective for extra-articular fractures of distal tibia. However, the former has the advantage of lowers rate of malformation and knee joint pain. Therefore a surgeon should consider the degree of injury while managing extra-articular fracture of distal tibia.

  5. Minimally invasive percutaneous plate fixation of distal tibia fractures.

    LENUS (Irish Health Repository)

    Bahari, Syah

    2007-10-01

    We report a series of 42 patients reviewed at a mean of 19.6 months after treatment of distal tibial and pilon fractures using the AO distal tibia locking plate with a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. Mean time to union was 22.4 weeks. All fractures united with acceptable alignment and angulation. Two cases of superficial infection were noted, with one case of deep infection. Mean SF36 score was 85 and mean AOFAS score was 90 at a mean of 19 months follow-up. We report satisfactory outcomes with the use of the AO distal tibia locking plate in treatment of unstable distal tibial fractures. Eighty-nine percent of the patients felt that they were back to their pre injury status and 95% back to their previous employment.

  6. Locking plate fixation for proximal humerus fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-02-01

    Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

  7. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    Directory of Open Access Journals (Sweden)

    Lokesh

    2016-05-01

    Full Text Available INTRODUCTION Most of these fractures except intra-articular fractures are treated with interlocking nail. 1,2 These nails are a boon for these fractures. But as the fracture nears to the joint stability the fracture fixation will be compromised due to malreduction and alignment, it leads to increased chances of delayed and nonunion. 3 Locking anatomical plates are evaluated for anatomical and relative stability fixation. Since then most intra and near intra-articular fractures are fixed with these plates with minimally invasive percutaneous plate osteosynthesis method, these plates have given excellent result 4 . But again these plates have some disadvantages 5 . This study is done to see the outcome of locking plates in distal tibia fracture. METHODS This study is done in the Department of Orthopaedics, Bangalore Medical College, Bangalore. This study is done from 2013 to 2015. 30 patients who came to outpatient department were treated with locking plates. All patients above 16 years having distal third tibia fracture are included. All open fractures except type 1 and elderly above 60 years and pathological fractures are excluded in our study. All patients were followed up for initial 5 months, thereafter, once in 3 months, for clinical and radiological evaluation of union status, knee range of motion, ankle range of motion and other complications. Assessment of the patient with functional recovery was done with American Orthopaedic Foot and Ankle Surgery(AOFAS 6 minimum 5 months after injury. RESULTS Majority of the patients are from age group 18-29 years (50%. Average age group was 30 years. Majority of the patients were males 80.6% (25. All fractures were closed fractures except 2 cases which are type 1. There were 12 cases of AO type A, 8 patients were AO type B and 10 patients were type C. Majority of the patients had fracture due to road traffic accidents, 74%. All fractures were united by the end of 20 weeks. There was delayed union in

  8. [Tibiotalocalcaneal arthrodesis using a humeral locking plate].

    Science.gov (United States)

    Cabrera Méndez, M P; Gamba, C; Hernández, E; Molano, J; Andrade, J C

    2016-01-01

    To describe the results of tibiotalocalcáneal arthrodesis (TTC) using a humeral locking plate. A retrospective, observational study was conducted between January 2007 and December 2013 in the Hospital Militar Central de Bogotá. The study included patients with symptomatic osteoarthritis diagnosed clinically and radiologically, and who underwent TTC arthrodesis using a humeral locking plate with a minimum follow up of 6 months. The total number patients was 35, of whom 7 (20%) were women and 28 (80%) men, with a mean age 36.3 years (19.77). 74% with post-traumatic arthritis, most of them secondary to gunshot wounds and fragmentation weapons, and neuropathic in 20%. An autogenous graft was used in 13 cases, and 14 cases using both, with a mean consolidation time of 4.37 months. Complications include, delayed union in 3 cases, and surgical site infection in 4. The postoperative functionality (AOFAS) mean was 66.7/100 points, with a score of 2.35 on a visual analogue pain scale. TTC arthrodesis using a humeral locking plate is a suitable option for fixing this type of arthrodesis, with a low rate of complications, and postoperative results that revealed satisfactory improvement in pain and consolidation. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  9. UK DRAFFT - A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

    Directory of Open Access Journals (Sweden)

    Brown Jaclyn

    2011-09-01

    Full Text Available Abstract Background Fractures of the distal radius are extremely common injuries in adults. However, the optimal management remains controversial. In general, fractures of the distal radius are treated non-operatively if the bone fragments can be held in anatomical alignment by a plaster cast or orthotic. However, if this is not possible, then operative fixation is required. There are several operative options but the two most common in the UK, are Kirschner-wire fixation (K-wires and volar plate fixation using fixed-angle screws (locking-plates. The primary aim of this trial is to determine if there is a difference in the Patient-Reported Wrist Evaluation one year following K-wire fixation versus locking-plate fixation for adult patients with a dorsally-displaced fracture of the distal radius. Methods/design All adult patients with an acute, dorsally-displaced fracture of the distal radius, requiring operative fixation are potentially eligible to take part in this study. A total of 390 consenting patients will be randomly allocated to either K-wire fixation or locking-plate fixation. The surgery will be performed in trauma units across the UK using the preferred technique of the treating surgeon. Data regarding wrist function, quality of life, complications and costs will be collected at six weeks and three, six and twelve months following the injury. The primary outcome measure will be wrist function with a parallel economic analysis. Discussion This pragmatic, multi-centre trial is due to deliver results in December 2013. Trial registration Current Controlled Trials ISRCTN31379280 UKCRN portfolio ID 8956

  10. The strength of polyaxial locking interfaces of distal radius plates.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2009-10-01

    Currently available polyaxial locking plates represent the consequent enhancement of fixed-angle, first-generation locking plates. In contrast to fixed-angle locking plates which are sufficiently investigated, the strength of the new polyaxial locking options has not yet been evaluated biomechanically. This study investigates the mechanical strength of single polyaxial interfaces of different volar radius plates. Single screw-plate interfaces of the implants Palmar 2.7 (Königsee Implantate und Instrumente zur Osteosynthese GmbH, Allendorf, Germany), VariAx (Stryker Leibinger GmbH & Co. KG, Freiburg, Germany) und Viper (Integra LifeSciences Corporation, Plainsboro, NJ, USA) were tested by cantilever bending. The strength of 0 degrees, 10 degrees and 20 degrees screw locking angle was obtained during static and dynamic loading. The Palmar 2.7 interfaces showed greater ultimate strength and fatigue strength than the interfaces of the other implants. The strength of the VariAx interfaces was about 60% of Palmar 2.7 in both, static and dynamic loading. No dynamic testing was applied to the Viper plate because of its low ultimate strength. By static loading, an increase in screw locking angle caused a reduction of strength for the Palmar 2.7 and Viper locking interfaces. No influence was observed for the VariAx locking interfaces. During dynamic loading; angulation had no influence on the locking strength of Palmar 2.7. However, reduction of locking strength with increasing screw angulation was observed for VariAx. The strength of the polyaxial locking interfaces differs remarkably between the examined implants. Depending on the implant an increase of the screw locking angle causes a reduction of ultimate or fatigue strength, but not in all cases a significant impact was observed.

  11. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates.

    Science.gov (United States)

    Hak, David J; Fader, Ryan; Baldini, Todd; Chadayammuri, Vivek B S

    2017-09-01

    Carbon-fibre reinforced polyetheretherketone (CFR-PEEK) plates have recently been introduced for proximal humerus fracture treatment. The purpose of this study was to compare the locking screw-plate interface stability in CFR-PEEK versus stainless steel (SS) proximal humerus plates. Locking screw mechanical stability was evaluated independently in proximal and shaft plate holes. Stiffness and load to failure were tested for three conditions: (1) on-axis locking screw insertion in CFR-PEEK versus SS plates, (2) on-axis locking screw insertion, removal, and reinsertion in CFR-PEEK plates, and (3) 10-degree off-axis locking screw insertion in CFR-PEEK plates. Cantilever bending at a rate of 1 mm/minute was produced by an Instron machine and load-displacement data recorded. Shaft locking screw load to failure was significantly greater in CFR-PEEK plates compared to SS plates (746.4 ± 89.7 N versus 596.5 ± 32.6 N, p PEEK plates (p PEEK plates. The mechanical stability of locking screws in CFR-PEEK plates is comparable or superior to locking screws in SS plates.

  12. Complication with Removal of a Lumbar Spinal Locking Plate

    Directory of Open Access Journals (Sweden)

    Brooke Crawford

    2015-01-01

    Full Text Available Introduction. The use of locking plate technology for anterior lumbar spinal fusion has increased stability of the vertebral fusion mass over traditional nonconstrained screw and plate systems. This case report outlines a complication due to the use of this construct. Case. A patient with a history of L2 corpectomy and anterior spinal fusion presented with discitis at the L4/5 level and underwent an anterior lumbar interbody fusion (ALIF supplemented with a locking plate placed anterolaterally for stability. Fifteen months after the ALIF procedure, he returned with a hardware infection. He underwent debridement of the infection site and removal of hardware. Results. Once hardware was exposed, removal of the locking plate screws was only successful in one out of four screws using a reverse thread screw removal device. Three of the reverse thread screw removal devices broke in attempt to remove the subsequent screws. A metal cutting drill was then used to break hoop stresses associated with the locking device and the plate was removed. Conclusion. Anterior locking plates add significant stability to an anterior spinal fusion mass. However, removal of this hardware can be complicated by the inherent properties of the design with significant risk of major vascular injury.

  13. Displaced proximal humeral fractures: an Indian experience with locking plates

    Directory of Open Access Journals (Sweden)

    Aggarwal Sameer

    2010-08-01

    Full Text Available Abstract Background The treatment of displaced proximal humerus fractures, especially in elderly, remains controversial. The objective of this study was to evaluate functional outcome of locking plate used for fixation of these fractures after open reduction. We also attempted to evaluate the complications and predictors of loss of fixation for such an implant. Methods Over two and a half years, 56 patients with an acute proximal humerus fracture were managed with locking plate osteosynthesis. 47 of these patients who completed a minimum follow up of 1 year were evaluated using Constant score calculation. Statistical analysis was done using SPSS 16 and a p value of less than 0.05 was taken as statistically significant. Results The average follow up period was around 21.5 months. Outcomes were excellent in 17%, good in 38.5%, moderate in 34% while poor in 10.5%. The Constant score was poorer for AO-OTA type 3 fractures as compared to other types. The scores were also inferior for older patients (> 65 years old. Complications included screw perforation of head, AVN, subacromial impingement, loss of fixation, axillary nerve palsy and infection. A varus malalignment was found to be a strong predictor of loss of fixation. Conclusion Locking plate osteosynthesis leads to satisfactory functional outcomes in all the patients. Results are better than non locking plates in osteoporotic fractures of the elderly. However the surgery has steep learning curve and various complications could be associated with its use. Nevertheless we believe that a strict adherence to the principles of locking plate use can ensure good result in such challenging fractures.

  14. [Development of polyaxial locking plate screw system of sacroiliac joint].

    Science.gov (United States)

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P 0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. The polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw

  15. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    OpenAIRE

    Lokesh; Dayanand; Deepak; Hemanth

    2016-01-01

    INTRODUCTION Most of these fractures except intra-articular fractures are treated with interlocking nail. 1,2 These nails are a boon for these fractures. But as the fracture nears to the joint stability the fracture fixation will be compromised due to malreduction and alignment, it leads to increased chances of delayed and nonunion. 3 Locking anatomical plates are evaluated for anatomical and relative stability fixation. Since then most intra and near intra-articul...

  16. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model.

    Science.gov (United States)

    Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B

    2009-12-01

    Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.

  17. Locking plates in distal humerus fractures: study of 43 patients

    Directory of Open Access Journals (Sweden)

    Gupta Rakesh Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: The treatment of multi-fragmentary, intraarticular fractures of the distal humerus is difficult, even in young patients with bone of good quality. Small distal fragment, diminished bone mineral quality and increased trauma-associated joint destruction make stable joint reconstruction more problematic. The anatomically preshaped locking plates allow angular stable fixation for these complex fractures. We evaluated functional results of patients treated with open reduction and internal fixation with distal humerus locking plates for complex distal hu-merus fractures. Methods: Forty-three consecutive patients with ar-ticular fractures of the distal humerus were treated by open reduction and internal fixation with AO distal humerus plate system and locking reconstruction plates. Forty patients were available for the final outcome analysis. According to AO/ASIF classification, there were 2 cases of type A2, 4 cases of type A3, 1 case of type B1, 1 case of type B2, 14 cases of type C1, 7 cases of type C2 and 11 cases of type C3. Open reduction with triceps splitting technique was used in all patients. The clinical and radiographic follow-up was performed and outcome measures included pain assessment, range of motion, and Mayo elbow performance score. Results: Forty patients were available for the final outcome analysis. There were 29 males and 11 females with an average age of 38.4 years (18-73 years. Clinical and ra-diological consolidation of the fracture was observed in all cases at an average of 11.6 weeks (9-14 weeks. The average follow-up was 12 months (10-18 months. Using the Mayo elbow performance score the results obtained were graded as excellent or good results in 33 patients (82.5%. One pa-tient had superficial infection, and 4 had myositis ossificans. There were no cases of primary malposition or secondary displacement, implant failure or ulnar neuropathy. Conclusion: Anatomically preshaped distal humerus locking

  18. Fractures of the distal tibia treated with polyaxial locking plating.

    Science.gov (United States)

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2009-03-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial infections and evidence of delayed wound healing. Using the American Orthopaedic Foot and Ankle Society ankle score, the average functional score was 87.3 points (of 100 total possible points). Our results show the polyaxial locking plates, which offer more fixation versatility, may be a reasonable treatment option for distal tibia fractures with very short metaphyseal segments.

  19. [Curative efficacies of mini-invasive percutaneous osteosynthesis versus supercutaneous plating for distal tibial fractures].

    Science.gov (United States)

    He, Xianfeng; Zhu, Limei; Zhang, Jingwei; Li, Ming; Yu, Yihui

    2014-12-30

    To compare the clinical efficacies of mini-invasive percutaneous osteosynthesis (MIPO) versus supercutaneous plating with closed reduction in the treatment of distal tibial fractures. A total of 48 patients with close distal tibial fractures were treated between January 2010 and January 2012. The MIPO group included 16 males and 8 females with an average age of 36 years. And the types were A (n = 15), B (n = 6) and C (n = 3) according to the classification scheme of Association for the Study of Internal Fixation (AO/ASIF). The supercutaneous plating group also included 16 males and 8 females with an average age of 37 years. And the types were A (n = 15), B (n = 6) and C (n = 3). And the operative duration, hospital stay, union time, postoperative complications and function of ankle were compared between two groups. The mean follow-up period was 18.5 (12-26) months. There was no instance of nonunion, hardware breakdown or deep infection. Patients in supercutaneous plating group had significantly shorter mean operative duration, hospital stay and union time. Three patients and 1 patient in MIPO group presented with superficial infection and delayed union respectively while there was no occurrence in supercutaneous plating group. And the differences were not statistically significant. Fifteen patients (62.5%) complained of implant impingement or discomfort. And stripping occurred at an incidence of 15.6% during the removal time of locking screws in MIPO group. While in supercutaneous plating group, there as no complaint of skin irritation and removal of supercutaneous plate was easily performed without anesthesia. The mean AOFAS score was 90.7 ± 3.8 in supercutaneous plating group versus 88.9 ± 4.1 in MIPO group (P = 0.070). Distal tibia fractures may be treated successfully with MIPO or supercutaneous plating. However, supercutaneous plating offers multiple advantages in terms of mean operative duration, hospital stay, union time, skin irritation and implant

  20. Adult periarticular locking plates for the treatment of pediatric and adolescent subtrochanteric hip fractures.

    Science.gov (United States)

    Sanders, Samuel; Egol, Kenneth A

    2009-01-01

    Two cases are presented in which adult, precontoured, lower-extremity periarticular locking plates were utilized for fixation of subtrochanteric femur fractures in pediatric patients. Recognition of the fact that a distal tibial locking plate in a small child and a proximal tibial locking plate in an adolescent anatomically ft the proximal femur in each case may provide a surgeon treating subtrochanteric hip fractures in this population increased options for operative stabilization.

  1. A locking compression plate versus the gold-standard non-locking plate with lag screw for first metatarsophalangeal fusion: A biomechanical comparison.

    Science.gov (United States)

    Mandell, Daniel; Karbassi, John; Zhou, Hanbing; Burroughs, Brian; Aurigemma, Philip; Patel, Abhay R

    2018-03-01

    The treatment of end-stage first metatarso-phalangeal joint (MTP) arthritis has been arthrodesis. A dorsal non-locking plate with a lag screw has been the standard traditional fixation method. This study compares the biomechanical strength of a locking compression plate (LCP) with and without internal compression versus this known gold standard. In group 1, six matched pairs of cadaver great toes were used to compare the standard non-locking dorsal plate and 3.5mm lag screw to an anatomic locking compression plate in which a lag screw was utilized rather than the internal compression features of the plate. In group 2, another six matched pairs of cadaver great toes were used to compare the gold standard to the locking compression plate, utilizing the plate's internal compression feature instead of a lag screw. A material testing system (MTS) machine applied loads to the MTP joints and measured displacement and stiffness of the constructs. The stiffness of the constructs (Young's modulus) was calculated from the force-displacement curves, and the displacement was measured. The locking compression plate group that used the compression features of the plate, without the lag screw, had less joint displacement and higher stiffness than control (p<0.05). The same plating construct in which a lag screw was used rather than internal compression of the plate was found to be stiffer than the control (p<0.05), but displacement was not statistically significant. The results suggest that a locking compression plate alone provides the stiffest construct for a first MTP joint fusion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Use of locking plates for fixation of the greater trochanter in patients with hip replacement

    Directory of Open Access Journals (Sweden)

    Allison K. Tetreault, BA

    2016-12-01

    Conclusions: Locking plate technology is a successful method of fixation of the greater trochanter in patients with THA. Postoperative trochanteric pain and reoperation for hardware-related issues remain a challenge.

  3. Locking plate osteosynthesis in displaced 4-part fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Brorson, Stig; Frich, Lars H; Winther, Annika

    2011-01-01

    There is considerable uncertainty about the optimal treatment of displaced 4-part fractures of the proximal humerus. Within the last decade, locking plate technology has been considered a breakthrough in the treatment of these complex injuries....

  4. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    Science.gov (United States)

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  5. Use of a percutaneous osteotomy with plate fixation in hallux valgus correction.

    Science.gov (United States)

    Díaz Fernández, Rodrigo

    2017-09-20

    With hundreds of operative methods described for correction of hallux valgus we can state that the ideal surgical treatment is still controversial. The Bösch technique has been used as a percutaneous way of correcting hallux valgus deformities with the use of a pin fixation. The aim of this study is to evaluate a new method of fixation by using a percutaneous locking plate. Between June 2013 and January 2015, 24 consecutive percutaneous subcapital osteotomies of the first metatarsal bone were performed for the treatment of painful hallux valgus deformities in 24 patients. Additional surgical procedures included DMMO's (Distal Metatarsal Minimally-Invasive Osteotomies) in 12 of the operated feet (44.44%); minor digits were corrected in 7 cases (25.9%). An Akin procedure was performed in 81% of cases and all cases underwent an adductor hallucis tenotomy. All patients were clinically assessed using the AOFAS score. Radiographic measures included the preoperative and postoperative values of the Hallux Valgus Angle (HVA), Intermetatarsal Angle (IMA), and the Distal Metatarsal Articular Angle (DMAA). The mean correction achieved improved for AHV from 36.57±7.1 to 12.22±8.69°, for IMA from 13.8±1.59 to 7.08±2.72 and for DMAA from 13.98±7.38 to 6.07±4.99. Clinically, scores on the AOFAS scale improved from a 45.8±9.6 to 91.29±9.8. Although healing of the osteotomies was observed radiographically within 6 to 12 weeks, two cases (8.3%) exhibited delayed healing. There were no cases of nonunion. There were no superficial or deep infections or wound healing problems. Plate had to be removed in 3 cases (12.5%). This technique modification is an acceptable procedure to correct hallux valgus in patients with a moderate level of deformity. Level IV. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  6. First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

    Directory of Open Access Journals (Sweden)

    Leif Claassen

    2017-07-01

    Full Text Available Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis with crossed-screwsor with a nonlocking plate with lag screw. Results: There were four non-unions in crossed-screws patients and one nonunion in non-locked plate group. All the patients in locking plate group achieved union. 90% of the patients were completely or mildly satisfied in locking plate group, whereas this rate was 80% for patients in both crossed screws and non-locking plate groups. Conclusions: Use of dorsal plating for arthrodesis of MTP1 joint either locking or non-locking were associated with high union rate and acceptable and comparable functional outcome. Although nonunion rate was high using two crossed screws but functional outcome was not significantly different compare to dorsal plating. Level of evidence:Ш, retrospective comparative study

  7. A prospective, randomised trial comparing closed intramedullary nailing with percutaneous plating in the treatment of distal metaphyseal fractures of the tibia.

    Science.gov (United States)

    Guo, J J; Tang, N; Yang, H L; Tang, T S

    2010-07-01

    We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients' age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p fractures had united. Patients who had intramedullary nailing had a higher mean pain score (40 = no pain, 0 = severe pain), [corrected] but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with

  8. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.

    Science.gov (United States)

    Lujan, Trevor J; Henderson, Chris E; Madey, Steven M; Fitzpatrick, Dan C; Marsh, J Lawrence; Bottlang, Michael

    2010-03-01

    Locked plating constructs may be too stiff to reliably promote secondary bone healing. This study used a novel imaging technique to quantify periosteal callus formation of distal femur fractures stabilized with locking plates. It investigated the effects of cortex-to-plate distance, bridging span, and implant material on periosteal callus formation. Retrospective cohort study. One Level I and one Level II trauma center. Sixty-four consecutive patients with distal femur fractures (AO types 32A, 33A-C) stabilized with periarticular locking plates. Osteosynthesis using indirect reduction and bridge plating with periarticular locking plates. Periosteal callus size on lateral and anteroposterior radiographs. Callus size varied from 0 to 650 mm2. Deficient callus (20 mm2 or less) formed in 52%, 47%, and 37% of fractures at 6, 12, and 24 weeks postsurgery, respectively. Callus formation was asymmetric, whereby the medial cortex had on average 64% more callus (P=0.001) than the anterior or posterior cortices. A longer bridge span correlated minimally with an increased callus size at Week 6 (P=0.02), but no correlation was found at Weeks 12 and 24 postsurgery. Compared with stainless steel plates, titanium plates had 76%, 71%, and 56% more callus at Week 6 (P=0.04), Week 12 (P=0.03), and Week 24 (P=0.09), respectively. Stabilization of distal femur fractures with periarticular locking plates can cause inconsistent and asymmetric formation of periosteal callus. A larger bridge span only minimally improves callus formation. The more flexible titanium plates enhanced callus formation compared with stainless steel plates.

  9. Compartment syndrome like picture in metaphyseal comminuted fracture of tibia treated by locking plate due to tight closure

    Directory of Open Access Journals (Sweden)

    Prafulla Herode

    2013-01-01

    Full Text Available A 22-year-old male came to casualty on 5 th May 2012 after a fall from motorcycle. He complained of excruciating pain and swelling over right knee. There was an open wound of 7 × 2 cm over supra-patellar region and diffuse swelling over knee joint with severe tenderness over proximal aspect of right tibia. X-ray showed intra-articular fracture of proximal tibia extending to diaphysis classified as type 6 by Schatzker classification for proximal tibia, with fibula shaft transverse fracture. The skin over the fracture was contused. Debridement with primary wound closure was done in emergency. Skeletal traction was applied through a lower tibial Steinman pin. Patient was operated after 15 days when wound healed and swelling subsided. Locking plate was applied on medial aspect using Minimally invasive percutaneous plate osteosysthesis (MIPPO technique. Post-operatively over 4 hours patient developed severe pain and swelling in operated leg which mimicked compartment syndrome. Suture removal was done immediately in the ward from the distal aspect, which relieved the symptoms but lead to exposure of the plate. A rotational flap was done to cover the plate in coordination with a plastic surgeon on the next day.

  10. Comparative evaluation of 2.3 mm locking plate system vs conventional 2.0 mm non locking plate system for mandibular condyle fracture fixation: a seven year retrospective study.

    Science.gov (United States)

    Zhang, J; Wang, X; Wu, R-H; Zhuang, Q-W; Gu, Q P; Meng, J

    2015-01-01

    This retrospective study evaluated the efficacy of a 2.3 mm locking plate/screw system compared with a 2.0-mm non-locking plate/screw system in fixation of isolated non comminuted mandibular condyle fractures. Surgical records of 101 patients who received either a 2.3 mm locking plate (group A, n = 51) or 2.0 mm non locking plate (group B, n = 50) were analyzed. All patients were followed up to a minimum of 6 months postoperatively and evaluated for hardware related complications, occlusal stability, need for and duration of MMF and mandibular functional results. Four complications occurred in the locking group and eighteen in the non locking group with complication rates equalling 8% and 36% respectively. When comparing the overall results according to plates used, the χ2 test showed a statistically significant difference between the locking and non locking plates (p Mandibular condyle fractures treated with a 2.3 mm locking plate exhibited stable osteosynthesis, were associated with minimal complications and resulted in acceptable mandibular range of motion compared with a 2.0 mm non locking plate.

  11. Femoral fracture repair using a locking plate technique in an adult captive polar bear (Ursus maritimus).

    Science.gov (United States)

    Zimmerman, Dawn M; Dew, Terry; Douglass, Michael; Perez, Edward

    2010-02-01

    To report successful femoral fracture repair in a polar bear. Case report. Female polar bear (Ursus maritimus) 5 years and approximately 250 kg. A closed, complete, comminuted fracture of the distal midshaft femur was successfully reduced and stabilized using a compression plating technique with 2 specialized human femur plates offering axial, rotational, and bending support, and allowing the bone to share loads with the implant. Postoperative radiographs were obtained at 11.5 weeks, 11 months, and 24 months. Bone healing characterized by marked periosteal reaction was evident at 11 months with extensive remodeling evident at 24 months. No complications were noted. Distal mid shaft femoral fracture was reduced, stabilized, and healed in an adult polar bear with a locking plate technique using 2 plates. Previously, femoral fractures in polar bears were considered irreparable. Use of 2 plates applied with a locking plate technique can result in successful fracture repair despite large body weight and inability to restrict postoperative activity.

  12. Poor relation between biomechanical and clinical studies for the proximal femoral locking compression plate

    DEFF Research Database (Denmark)

    Viberg, Bjarke; Voergård Rasmussen, Katrine Marie; Overgaard, Søren

    2017-01-01

    Background and purpose — The proximal femur locking compression plate (PF-LCP) is a new concept in the treatment of hip fractures. When releasing new implants onto the market, biomechanical studies are conducted to evaluate performance of the implant. We investigated the relation between biomecha......Background and purpose — The proximal femur locking compression plate (PF-LCP) is a new concept in the treatment of hip fractures. When releasing new implants onto the market, biomechanical studies are conducted to evaluate performance of the implant. We investigated the relation between...

  13. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.

    Science.gov (United States)

    Ma, Ching-Hou; Tu, Yuan-Kun; Yeh, Jih-Hsi; Yang, Shih-Chieh; Wu, Chin-Hsien

    2011-09-01

    The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.

  14. Fractures of the Distal Tibia Treated with Polyaxial Locking Plating

    OpenAIRE

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2008-01-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial in...

  15. Treatment of proximal humerus fractures with locking plates: a systematic review.

    Science.gov (United States)

    Thanasas, Christos; Kontakis, George; Angoules, Antonios; Limb, David; Giannoudis, Peter

    2009-01-01

    Locking plates with special configuration for the anatomic region of the proximal humerus have been introduced recently to address the difficulties of stabilizing proximal humeral fractures. The purpose of this study was to carry out a systematic review of the literature on the efficacy and early to medium term functional results of locking plates for stabilization of proximal humeral fractures. Using the PubMed database, a systematic review of the English and German literature was carried out in order to assess the efficacy and complications related to the use of these plates and the patients' functional outcome, using the key words "locking plates proximal humeral fractures," "angular stability plates proximal humeral fractures," "PHILOS plate," and "LPHP plate." Our criteria for eligibility were clinical studies with more than ten cases followed-up, adult patients, and adequate data provided at least in terms of implant related complications. Articles written in English and German language were included. Exclusion criteria were: studies dealing exclusively with 2-part fractures (since this category has a more favorable outcome); experimental studies; case reports; and, literature other than English or German. Each one of the articles was evaluated for quality of the study using the Structured Effectiveness Quality Evaluation Scale (SEQES). Twelve studies including 791 patients met the inclusion criteria. Patients in these studies continued to improve up to one year, achieving a mean Constant score of 74.3. The incidence of the reported complications was: avascular necrosis 7.9%, screw cut-out 11.6% and re-operation rate 13.7%. The high incidence of cut-out may be secondary to the rigidity of the implant in combination with medial inadequate support, in cases compromised by severe underlying osteoporotic bone. Definition of indications for the use of locking plates and attention on technical aspects of applying them would help optimization of the results

  16. The mechanical benefit of medial support screws in locking plating of proximal humerus fractures.

    Directory of Open Access Journals (Sweden)

    Wen Zhang

    Full Text Available BACKGROUND: The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs in the locking proximal humeral plate for treating proximal humerus fractures. METHODS: Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal humerus plate. Group A was fixed with medial cortical support and no MSSs; Group B was fixed with 3 MSSs but without medial cortical support; Group C was fixed with neither medial cortical support nor MSSs. Axial compression, torsional stiffness, shear stiffness, and failure tests were performed. RESULTS: Constructs with medial support from cortical bone showed statistically higher axial and shear stiffness than other subgroups examined (P<0.0001. When the proximal humerus was not supported by medial cortical bone, locking plating with medial support screws exhibited higher axial and torsional stiffness than locking plating without medial support screws (P ≤ 0.0207. Specimens with medial cortical bone failed primarily by fracture of the humeral shaft or humeral head. Specimens without medial cortical bone support failed primarily by significant plate bending at the fracture site followed by humeral head collapse or humeral head fracture. CONCLUSIONS: Anatomic reduction with medial cortical support was the stiffest construct after a simulated two-part fracture. Significant biomechanical benefits of MSSs in locking plating of proximal humerus fractures were identified. The reconstruction of the medial column support for proximal humerus fractures helps to enhance mechanical stability of the humeral head and prevent implant failure.

  17. Plate fixation in periprosthetic femur fractures Vancouver type B1-Trochanteric hook plate or subtrochanterical bicortical locking?

    Science.gov (United States)

    Lenz, Mark; Stoffel, Karl; Kielstein, Heike; Mayo, Keith; Hofmann, Gunther O; Gueorguiev, Boyko

    2016-12-01

    Proximal plate fixation in periprosthetic femur fractures can be improved by plate anchorage in the greater trochanter (lateral tension band principle) or bicortical locking screw placement beside the prosthesis stem in an embracement configuration. Both concepts were compared in a biomechanical test using a femoral hook plate (hook) or a locking attachment plate (LAP). After bone mineral density (BMD) measurement in the greater trochanter, six pairs of fresh frozen human femora were assigned to two groups and instrumented with cemented hip endoprostheses. A transverse osteotomy was set distal to the tip of the prosthesis, simulating a Vancouver B1 fracture. Each pair was instrumented using a plate tensioner with either hook or LAP construct. Cyclic testing (2Hz) with physiologic profile and monotonically increasing load was performed until catastrophic failure. Plate stiffness was compared in a four-point-bending-test. Paired student's-t-test was used for statistical evaluation (pTrochanteric fixation is highly BMD dependent and may be restricted to major greater trochanteric involvement requiring stabilization. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. The Dynamic Locking Blade Plate : innovation in the treatment of femoral neck fractures

    NARCIS (Netherlands)

    Roerdink, W.H.

    2011-01-01

    The scope of this thesis was to describe the design and development of the Dynamic Locking Blade Plate (DLBP), an improved internal fixation (IF) device for intracapsular hip fractures. This thesis focuses on intracapsular hip fractures since the results of current surgical treatment of this type of

  19. Computational modelling of long bone fractures fixed with locking plates - How can the risk of implant failure be reduced?

    LENUS (Irish Health Repository)

    Nassiri, M

    2013-03-01

    The Locking Compression Plate (LCP) is part of a new plate generation requiring an adapted surgical technique and new thinking about commonly used concepts of internal fixation using plates. Knowledge of the fixation stability provided by these new plates is very limited and clarification is still necessary to determine how the mechanical stability and the risk of implant failure can best be controlled.

  20. Evaluation of Bone Atrophy After Treatment of Forearm Fracture Using Nonlinear Finite Element Analysis: A Comparative Study of Locking Plates and Conventional Plates.

    Science.gov (United States)

    Matsuura, Yusuke; Rokkaku, Tomoyuki; Suzuki, Takane; Thoreson, Andrew Ryan; An, Kai-Nan; Kuniyoshi, Kazuki

    2017-08-01

    Forearm diaphysis fractures are usually managed by open reduction internal fixation. Recently, locking plates have been used for treatment. In the long-term period after surgery, some patients present with bone atrophy adjacent to the plate. However, a comparison of locking and conventional plates as a cause of atrophy has not been reported. The aim of this study was to investigate long-term bone atrophy associated with use of locking and conventional plates for forearm fracture treatment. In this study we included 15 patients with forearm fracture managed by either locking or conventional plates and with more than 5 years of follow-up. Computed tomographic imaging of both forearms was performed to assess bone thickness and local bone mineral density and to predict bone strength without plate reinforcement based on finite element analysis. Mean patient age at surgery was 48.0 years. Eight patients underwent reduction with fixed locking plates and were followed up for a mean of 79.5 months; the remaining 7 patients were treated with conventional plates and were followed up for a mean of 105.0 months. Compared with the conventional plate group, the locking plate group had the same fractured limb-contralateral limb ratio of cortex bone thickness, but had significantly lower ratios of mineral density adjacent to the plate and adjusted bone strength. This study demonstrated bone atrophy after locking plate fixation for forearm fractures. Treatment plans for forearm fracture should take into consideration the impact of bone atrophy long after plate fixation. Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.

    Science.gov (United States)

    Darrow, Brett G; Biskup, Jeffrey J; Weigel, Joseph P; Jones, Michael P; Xie, Xie; Liaw, Peter K; Tharpe, Josh L; Sharma, Aashish; Penumadu, Dayakar

    2017-05-01

    OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.

  2. Treatment for proximal humeral fractures with percutaneous plating: our first results.

    Science.gov (United States)

    Imarisio, D; Trecci, A; Sabatini, L; Scagnelli, R

    2013-06-01

    Proximal humeral fractures are common lesions; there is no generally accepted strategy about the treatment for displaced and unstable two- to four-part fractures. We have nowadays many different surgical solutions, ranging from percutaneous pinning to shoulder arthroplasty. Percutaneous plating can be a good solution to treat some of these fractures using a minimally invasive technique and performing stable fixation that can allow early mobilization. Purpose of this paper is to evaluate the results of our first cases of percutaneous plating in proximal humeral fractures in order to assess the theoretical advantages and the incidence of possible complications. From June 2009 to February 2012, we treated 29 proximal humeral fractures with a percutaneous plating (NCB-PH plate) through an anterolateral deltoid split. For each patient, we evaluated the clinical outcome according to Constant score and the radiographic results, paying attention to fracture healing, loss of reduction, hardware complications, and head necrosis. The clinical evaluation gave a mean Constant score value of 79 points. Comparing each value to the unaffected shoulder, we could find these results: 7 excellent, 10 good, 8 fair, and 4 poor. No axillary nerve lesions were clinically detected. The radiographic evaluation showed a complete bone healing in all cases within the first 3 months. No head necrosis was detected, as well as screws loosening. In two cases, the X-ray at 2 months revealed a little loss of reduction in varus. Two patients had an anterior pain; in one of these two cases, the plate was removed. In our series, we had no cases of head necrosis, screws cutout, fracture collapse, hardware mobilization, and we think this could be the real advantage of the percutaneous technique compared to the open one, thanks to the reduced biological damage. We had some poor results, related more to patient's age than to other factors. The safety of the technique for the axillary nerve is

  3. A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

    Directory of Open Access Journals (Sweden)

    Prakash Jayakumar

    2015-04-01

    Full Text Available Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking screw, which must also avoid the olecranon, coronoid, and radial fossae. We describe 3 patients (ages 27, 49, and 73 years with a bicolumnar fracture of the distal humerus where very short distal locking screws were used. Intra-articular screw placement was avoided but loss of fixation occurred in two patients and a third was treated with a prolonged period of immobilization. We postulate that fixed-angle screw trajectories may make it difficult for the surgeon to place screws of adequate length in this anatomically confined region, and may lead to insufficient distal fixation. Surgical tactics should include placement of as many screws as possible into the distal fragment, as long as possible, and that each screw pass through a plate without necessarily locking in.

  4. External fixation using locking plate in distal tibial fracture: a finite element analysis.

    Science.gov (United States)

    Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei

    2015-08-01

    External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.

  5. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients

    OpenAIRE

    Gupta, Rakesh K.; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2009-01-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-...

  6. [Effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture].

    Science.gov (United States)

    Yan, Rongliang; Qu, Jiafu; Cao, Lihai; Liu, Hongda; Chen, Jianghua; Gao, Yan; Peng, Yi

    2018-05-01

    To summarize the effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture. Between January 2011 and October 2016, 25 cases with comminuted Jones fracture were treated with mini locking plate combined with Kirschner wire. There were 9 males and 16 females with an average age of 31.4 years (range, 16-66 years). The fractures located on the left side in 11 cases and on the right side in 14 cases. The causes of injury included spraining in 21 cases, falling down in 3 cases, and bruise in 1 case. The bone fragment of all cases was more than 3 pieces. The fracture line was mostly Y-shape or T-shape. Twelve of them were combined with other fractures. The time from injury to operation was 1-9 days (mean, 5 days). The mini locking plate and Kirschner wire were removed at 9-12 months postoperatively. At 12 months postoperatively, the pain was evaluated by the visual analogue scale (VAS) score, and the function by the American Orthopaedic Foot & Ankle Society (AOFAS) score. All incisions healed by first intention. All cases were followed up 12-36 months with an average of 21.7 months. Fracture union was observed in all patients without complications such as nonunion, delayed union, and malunion. The fracture union time was 8-12 weeks (mean, 9.4 weeks). At 12 months postoperatively, the VAS score was 1.15±0.87; the AOFAS score was 89.45±6.24, and the results were excellent in 14 cases, good in 9 cases, fair in 1 case, and poor in 1 case, with an excellent and good rate of 92%. The procedure of mini locking plate combined with Kirschner wire for comminuted Jones fracture has such advantages as convenient operation, more rigid fixation, high rate of fracture healing, and good functional recovery in foot.

  7. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.

    Science.gov (United States)

    Röderer, Götz; Scola, Alexander; Schmölz, Werner; Gebhard, Florian; Windolf, Markus; Hofmann-Fliri, Ladina

    2013-10-01

    Proximal humerus fracture fixation can be difficult because of osteoporosis making it difficult to achieve stable implant anchorage in the weak bone stock even when using locking plates. This may cause implant failure requiring revision surgery. Cement augmentation has, in principle, been shown to improve stability. The aim of this study was to investigate whether augmentation of particular screws of a locking plate aimed at a region of low bone quality is effective in improving stability in a proximal humerus fracture model. Twelve paired human humerus specimens were included. Quantitative computed tomography was performed to determine bone mineral density (BMD). Local bone quality in the direction of the six proximal screws of a standard locking plate (PHILOS, Synthes) was assessed using mechanical means (DensiProbe™). A three-part fracture model with a metaphyseal defect was simulated and fixed with the plate. Within each pair of humeri the two screws aimed at the region of the lowest bone quality according to the DensiProbe™ were augmented in a randomised manner. For augmentation, 0.5 ml of bone cement was injected in a screw with multiple outlets at its tip under fluoroscopic control. A cyclic varus-bending test with increasing upper load magnitude was performed until failure of the screw-bone fixation. The augmented group withstood significantly more load cycles. The correlation of BMD with load cycles until failure and BMD with paired difference in load cycles to failure showed that augmentation could compensate for a low BMD. The results demonstrate that augmentation of screws in locked plating in a proximal humerus fracture model is effective in improving primary stability in a cyclic varus-bending test. The augmentation of two particular screws aimed at a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality

  8. Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Jiang-Jun Zhou

    2017-01-01

    Full Text Available In this study, we developed and validated a refined three-dimensional finite element model of middle femoral comminuted fracture to compare the biomechanical stability after two kinds of plate fixation: a newly designed assembly locking compression plate (NALCP and a locking compression plate (LCP. CT data of a male volunteer was converted to middle femoral comminuted fracture finite element analysis model. The fracture was fixated by NALCP and LCP. Stress distributions were observed. Under slow walking load and torsion load, the stress distribution tendency of the two plates was roughly uniform. The anterolateral femur was the tension stress area, and the bone block shifted toward the anterolateral femur. Maximum stress was found on the lateral border of the number 5 countersink of the plate. Under a slow walking load, the NALCP maximum stress was 2.160e+03 MPa and the LCP was 8.561e+02 MPa. Under torsion load, the NALCP maximum stress was 2.260e+03 MPa and the LCP was 6.813e+02 MPa. Based on those results of finite element analysis, the NALCP can provide adequate mechanical stability for comminuted fractures, which would help fixate the bone block and promote bone healing.

  9. Functional Results of Unstable (Type 2 Distal Clavicle Fractures Treated with Superior Anterior Locking Plate

    Directory of Open Access Journals (Sweden)

    Rajesh Govindasamy

    2017-11-01

    Full Text Available Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior locking plate.Methods: From June 2011 to August 2015 a retrospective study of12 male patients (mean age of 41.3 years 11 withunilateral and 1 with bilateral distal clavicle fractures treated with superior anterior locking plate was done. They wereevaluated at regular intervals with mean follow up of 14 months(12-18 months.Those with minimum one year followup were included in our study. All were evaluated for the functioning of the shoulder joint by both Oxford shoulder scoreand Quick DASH scores, rate of bone union, complications and earliest time for return to work.Results: All fractures union seen within 6-8 weeks (mean time: 7.1 weeks.All had good shoulder range of motion. Theaverage oxford shoulder and Quick DASH score were 46.2 and 6.5.There were no major complications in our studyviz. non-union, plate failure, secondary fracture. But one patient had superficial wound infection. All patients returned towork within 3 months of postoperative period.Conclusion: Displaced distal clavicle fractures treated with superior anterior locking plates achieved excellent resultsin terms of bony union with rarely any complications and demonstrate promising results with this novel technique.

  10. A FUNCTIONAL EVALUATION STUDY OF DISTAL FEMORAL FRACTURES FIXED WITH DISTAL FEMORAL LOCKING PLATE

    Directory of Open Access Journals (Sweden)

    Manikumar C. J

    2017-04-01

    Full Text Available BACKGROUND Fractures of the distal femur present considerable challenges in management. Older patients especially women sustain fractures due to osteoporosis. Supracondylar fractures of femur have a bimodal distribution. They account for 6% of all femur fractures and 31% if hip fractures were excluded. Nearly, 50% of distal femur intra-articular fractures are open fractures. Before 1970, most supracondylar fractures were treated nonoperatively; however, difficulties were often encountered including persistent angulatory deformity, knee joint incongruity, loss of knee motion and delayed mobilisation. The trend of open reduction and internal fixation has become evident in recent years with good results being obtained with AO blade plate, dynamic condylar screw, intramedullary supracondylar nail and locking compression plate. Elderly patients and osteoporosis pose difficulty in treating intra-articular fractures of the lower end of femur. Loss of stable fixation is of great concern in these cases. Hence, locking compression plate use has an advantage in these patients. MATERIALS AND METHODS In this study, 20 patients with closed fracture of distal femur were studied. All the cases were treated at the Department of Orthopaedics, Rangaraya Medical College/Government General Hospital, Kakinada, Andhra Pradesh, between November 2013 and November 2015. The method used for fracture fixation was open reduction and internal fixation with distal femoral locking plate. The duration of follow up ranged from 3 months to 24 months. All the fractures in this series were posttraumatic. The patients were functionally evaluated with Neer’s scoring system. 1 RESULTS Twenty distal femoral fractures were treated with distal femoral locking plates. 15 patients were males and 5 patients were females. The median age was 47 years ranging from 28-70 years. 16 of the fractures were caused by road traffic accidents and 2 were due to fall, 2 were due to assault. 12 patients

  11. Locking internal fixator with minimally invasive plate osteosynthesis for the proximal and distal tibial fractures

    Directory of Open Access Journals (Sweden)

    TONG Da-ke

    2012-02-01

    Full Text Available 【Abstract】Objective: To investigate the efficacy of the locking internal fixator (LIF, which includes the locking compression plate (LCP and the less invasive stable system (LISS, in the proximal and distal tibial fractures. Methods: We did a retrospective study on a total of 98 patients with either proximal or distal tibial fractures from January 2003 to January 2007, who had received the opera- tion with LIF by the minimally invasive plate osteosynthesis (MIPO technique. The data consisted of 43 proximal tibial fractures (type AO41C3 and 55 distal tibial fractures (type AO43C3. Results: No complications were observed in all patients after operation. The mean healing time was 8.4 months (range 5-14 months. Only two cases of delayed union occurred at postoperative 10 months. No infections were reported after the definitive surgery even in the cases of open fractures. All patients reached a full range of motion at postoperative 6 to 9 months and regained the normal functions of knee and ankle joints. Conclusion: Using LIF in MIPO technique is a reliable approach towards the proximal and distal tibial fractures that are not suitable for intramedullary nailing. Key words: Internal fixator; Tibial fractures; Fracture fixation, intramedullary; Bone plates

  12. Supraglenoid tubercle fractures repair with transverse locking compression plates in 4 horses.

    Science.gov (United States)

    Ahern, B J; Bayliss, I P M; Zedler, S T; Getman, L M; Richardson, D W

    2017-05-01

    To report on a series of 4 horses with supraglenoid tubercle fractures repaired with locking compression plates. Case series. Four horses ranging in age from 6 weeks to 20 months and weighing from 121 to 425 kg with supraglenoid tubercle fractures of 1 day to 6 weeks in duration. Supraglenoid tubercle fractures were reduced and stabilized with transversely positioned locking compression plate(s) with and without additional tension band wiring. All fractures reached bony union. Two postoperative surgical site infections were managed with drainage and antibiotherapy. Three of the 4 horses continued onto athletic careers including flat racing, dressage, and hunter/jumper competition. The remaining horse was lame for a prolonged period, but was sound at 4 years. The application of one or two, transversely positioned LCPs should be considered for the repair of SGT fractures because of the relative ease of the technique, and its elimination of a biceps brachii tenotomy. All screws can be inserted in a lateral to medial direction without transection or drill penetration of the biceps brachii tendon. SGT fractures of various durations can be repaired in a wide range of horses with transversely positioned LCPs, and allow return to athletic function. © 2017 The American College of Veterinary Surgeons.

  13. Locking device of a guiding ring on a plate including an aperture; application to guide tube of nuclear reactor

    International Nuclear Information System (INIS)

    Cauquelin, C.; Poitrenaud, P.

    1987-01-01

    To make easy to take to pieces a guide tube, by a simple tool, this device includes a guide ring. This guide ring aligned with an aperture in a plate has a tubular support fixed to the plate and coaxial with the aperture and lock the guide tube by rotation [fr

  14. Perioperative lateral trochanteric wall fractures: sliding hip screw versus percutaneous compression plate for intertrochanteric hip fractures.

    Science.gov (United States)

    Langford, Joshua; Pillai, Gita; Ugliailoro, Anthony D; Yang, Edward

    2011-04-01

    This study was performed to determine the incidence of perioperative lateral wall fractures with a standard sliding hip screw (SHS) versus a percutaneous compression plate (PCCP) using identical meticulous closed reduction techniques in both groups. Retrospective analysis of a prospective trauma registry. Urban Level I trauma center. Over a 7-year period, 337 patients with intertrochanteric hip fractures were treated with either a SHS or a PCCP at our institution. The PCCP group (Group 1) consisted of 200 patients, of which 141 (71%) had adequate images to be included in the study. The SHS group (Group 2) consisted of 137 patients, of which 100 (73%) had adequate images to be included in the study. Closed reduction and plate application with either a standard sliding hip screw or a percutaneous compression plate for an Orthopaedic Trauma Association 31A1 or 31A2 intertrochanteric hip fracture. : Radiographic evidence of lateral trochanteric wall fracture as measured by intraoperative and perioperative radiographs. There was an overall lateral wall fracture incidence of 20% in the SHS group versus 1.4% in the PCCP group (P fracture types, there was a lateral wall fracture incidence of 29.8% in the SHS group versus 1.9% in the PCCP group (P trochanteric wall fracture compared with the SHS group. This difference became greater when just unstable intertrochanteric fractures were analyzed. An anatomic reduction, combined with a device (PCCP) that uses small-diameter defects in the lateral trochanteric wall, essentially eliminates perioperative lateral trochanteric wall fractures.

  15. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

    Science.gov (United States)

    Gupta, Rakesh K; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2010-12-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures (n = 41) to maintain the second column of the ankle so as to achieve indirect reduction and to prevent collapse of the fracture. There were two cases of delayed wound breakdown in fractures fixed with the 4.5-mm LC-LCP. Five patients required primary bone grafting and three patients required secondary bone grafting. All cases of delayed union (n = 7) and nonunion (n = 3) were observed in cases where plates were used in bridge mode. Minimally invasive plate osteosynthesis (MIPO) with LCP was observed to be a reliable method of stabilisation for these fractures. Peri-operative docking of fracture ends may be a good option in severely impacted fractures with gap. The precontoured distal medial tibial LCP was observed to be a better tolerated implant in comparison to the 4.5-mm LC-LCP or metaphyseal LCP with respect to complications of soft tissues, bone healing and functional outcome, though its contour needs to be modified.

  16. A STUDY OF SURGICAL MANAGEMENT OF DISTAL FEMORAL FRACTURES BY DISTAL FEMORAL LOCKING COMPRESSION PLATE OSTEOSYNTHESIS

    Directory of Open Access Journals (Sweden)

    Dema Rajaiah

    2016-08-01

    Full Text Available AIMS AND OBJECTIVES To study the fractures of distal end of femur and the mechanism of injury in distal end femur fractures, the advantages and disadvantages of open reduction and internal fixation of distal end femur fractures by distal femoral locking compression plate osteosynthesis and to analyse the outcome in terms of range of Knee motion, time to union, and limb shortening. RESULTS The mean age of patient is 44 years, 85% are males, road traffic accidents account for majority (80%, right side involved in 70%, Muller’s type C fracture is common, good range of movements is seen 90% of cases and union occurred in 95% in 5 months. The results were assessed using Neer’s score, seven (35% patients had excellent results, eight (40% patients had good results, four (20% patients had fair results and one (5% patient had poor result. CONCLUSION From our study, we conclude that DF-LCP is a safe and reliable implant and has shown excellent to satisfactory results in majority of intra-articular fractures (AO type C. Fixation with locking compression plate showed more effectiveness in severely osteoporotic bones, shorter operative stay, faster recovery, faster union rates and excellent functional outcome.

  17. Osteosynthesis with long volar locking plates for meta- physeal-diaphyseal fractures of the distal radius

    Directory of Open Access Journals (Sweden)

    Gogna Paritosh

    2013-12-01

    Full Text Available 【Abstract】Objective: Metaphyseal-diaphyseal fractures of the distal radius are a major treatment dilemma and orthopaedic surgeons have to pay due consideration to restoration of anatomy of distal radius together with ro- tation of the radial shaft and maintenance of radial bow and interosseous space. We performed this study to evaluate the clinic-radiological outcome of metaphyseal-diaphyseal fractures of the distal radius treated with long volar locking plates. Methods: This prospective study involved 27 pa- tients (22 males and 5 females with metaphyseal-diaphy- seal fracture of the distal radius. Their mean age was (30.12± 11.48 years (range 19-52 years and the follow-up was 26.8 months (range 22-34 months. All patients underwent open reduction and internal fixation with a long volar locking plate. According to AO/OTA classification, there were 7 type A3, 13 type C2 and 7 type C3 fractures. Subjective assessment was done based on the disabilities of the arm, shoulder and hand (DASH questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist and the radiological determinants included radial angle, radial length, volar angle and ulnar variance. The final as- sessment was done according to Gartland and Werley scor- ing system. Results: Postoperative radiological parameters were well maintained throughout the trial, and there was signifi- cant improvement in the functional parameters from 6 weeks to final follow-up. The average DASH scores improved from 37.5 at 6 weeks to 4.2 at final follow-up. Final assessment using Gartland and Werley scoring system revealed 66.67% (n=18 excellent and 33.33% (n=9 good results. There was one case of superficial infection which responded to antibi- otics and another carpel tunnel syndrome which was ma- naged conservatively. Conclusion: Volar locking plate fixation for metaphy- seal-diaphyseal fractures of distal radius is associated with excellent to good

  18. It is time for a better clip applier - 3 mm, percutaneous, non-crushing and locking.

    Science.gov (United States)

    Yuval, Jonathan B; Weiss, Daniel J; Paz, Adrian; Bachar, Yehuda; Brodie, Ronit; Shapira, Yinon; Mintz, Yoav

    2017-10-06

    Since the advent of laparoscopy there have been attempts to minimize abdominal wall incisions. For this purpose smaller instruments have been produced. Our aim was to develop the first 3 mm percutaneous clip applier and to make it better than the standard clips of today. The ClipTip clip is made of Nitinol and has a crocodile shaped jaws, which when apposed effectively seal vessels. The shaft operates as a retractable needle permitting percutaneous insertion. Closing, reopening and reclosing is possible. The physical properties of the device were compared to three commercially available clip appliers. Surgeries were performed on porcine animals by experienced surgeons. In comparison to available clips, the superiority of the ClipTip is a combination of wide effective length alongside the ability to withstand strong forces. In live animal studies the Cliptip was inserted into the peritoneal cavity without any injuries. Vessels were ligated successfully and no clip dislodgement or leakage occurred. We developed the next generation clip applier with better properties. Advantages include its length, the needleoscopic caliber, non-crushing effect, locking mechanism and wide aperture. The device has performed safely and effectively in pre-clinical tests. Further studies are planned in humans.

  19. Percutaneous sacroiliac screw versus anterior plating for sacroiliac joint disruption: A retrospective cohort study.

    Science.gov (United States)

    Zhang, Ruipeng; Yin, Yingchao; Li, Shilun; Hou, Zhiyong; Jin, Lin; Zhang, Yingze

    2018-02-01

    Sacroiliac joint disruption (SJD) is a common cause of pelvic ring instability. Clinically, percutaneous unilateral S1 sacroiliac screw and anterior plating are always applied to manage SJD. The objective of this study is to elaborate their respective therapeutic traits. Patients with SJD fixed with unilateral S1 sacroiliac screw or anterior plating from June 2011 to June 2015 were recruited into this study and were divided into two groups: group A (unilateral sacroiliac screw) and group B (anterior plating). Surgical time, blood loss, frequency of intraoperative fluoroscopy and complications were reviewed. Postoperative radiograph and CT were conducted to assess the reduction quality. Fracture healing was evaluated by radiograph performed at each follow-up. Majeed score was recorded at the final follow-up to assess the functional outcome. Thirty-eight patients were included in group A and thirty-two patients in group B in this study. There was no significant difference in the demographic data of the two groups. A significant difference existed in the results for average operation time (P = .022) and blood loss (P = .000) between group A and group B. The mean frequency of intraoperative fluoroscopy was 15.82 in group A and 3.94 in group B (P = .000). All the fractures healed in this study. The rates of satisfactory reduction quality and functional outcome showed no significant difference between the two groups (P > .05). The complication rate was 15.79% (6/38) in group A and 9.38% (3/32) in group B (P = .660). Compared with anterior plating, percutaneous unilateral S1 sacroiliac screw usage is less invasive; however, more intraoperative X-ray exposure and permanent neurologic damage may accompany this procedure. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  20. [APPLICATION OF BUTTERFLY SHAPED LOCKING COMPRESSION PLATE IN COMPLEX DISTAL RADIUS FRACTURES].

    Science.gov (United States)

    Jiang, Zongyuan; Ma, Tao; Xia, Jiang; Hu, Caizhi; Xu, Lei

    2014-06-01

    To investigate the effectiveness of butterfly shaped locking compression plate for the treatment of complex distal radius fractures. Between June 2011 and January 2013, 20 cases of complex distal radius fractures were treated with butterfly shaped locking compression plate fixation. There were 11 males and 9 females with an average age of 54 years (range, 25-75 years). Injury was caused by falling in 10 cases, by traffic accident in 7 cases, and by falling from height in 3 cases. All of fractures were closed. According to AO classification system, there were 8 cases of type C1, 8 cases of type C2, and 4 cases of type C3. Of them, 9 cases had radial styloid process fracture, 4 cases had sigmoid notch fracture, and 7 cases had both radial styloid process fracture and sigmoid notch fracture. The mean interval between injury and operation was 5.2 days (range, 3-15 days). All incisions healed by first intention; no complications of infection and necrosis occurred. All cases were followed up 14 months on average (range, 10-22 months). All factures healed after 9.3 weeks on average (range, 6-11 weeks). No complications such as displacement of fracture, joint surface subsidence, shortening of the radius, and carpal tunnel syndrome were found during follow-up. At last follow-up, the mean palmar tilt angle was 10.2° (range, 7-15°), and the mean ulnar deviation angle was 21.8° (range, 17-24°). The mean range of motion of the wrist was 45.3° (range, 35-68°) in dorsal extension, 53.5° (range, 40-78°) in palmar flexion, 19.8° (range, 12-27°) in radial inclination, 26.6° (range, 18-31°) in ulnar inclination, 70.2° (range, 45-90°) in pronation, and 68.4° (range, 25-88°) in supination. According to the Dienst scoring system, the results were excellent in 8 cases, good in 10 cases, and fair in 2 cases, and the excellent and good rate was 90%. Treatment of complex distal radius fractures with butterfly shaped locking compression plate can reconstruct normal anatomic

  1. Minimally invasive locked plating of distal tibia fractures is safe and effective.

    Science.gov (United States)

    Ronga, Mario; Longo, Umile Giuseppe; Maffulli, Nicola

    2010-04-01

    Distal tibial fractures are difficult to manage. Limited soft tissue and poor vascularity impose limitations for traditional plating techniques that require large exposures. The nature of the limitations for traditional plating techniques is intrinsic to the large exposure required to approach distal tibia, a bone characterized by limited soft tissue coverage and poor vascularity. The locking plate (LP) is a new device for treatment of fractures. We assessed the bone union rate, deformity, leg-length discrepancy, ankle range of motion, return to preinjury activities, infection, and complication rate in 21 selected patients who underwent minimally invasive osteosynthesis of closed distal tibia fractures with an LP. According to the AO classification, there were 12 Type A, 5 Type B, and 4 Type C fractures. The minimum followup was 2 years (average, 2.8 years; range, 2-4 years). Two patients were lost to followup. Union was achieved in all but one patient by the 24th postoperative week. Four patients had angular deformity less than 7 degrees . No patient had a leg-length discrepancy more than 1.1 cm. Five patients had ankle range of motion less than 20 degrees compared with the contralateral side. Sixteen patients had not returned to their preinjury sporting or leisure activities. Three patients developed a delayed infection. We judge the LP a reasonable device for treating distal tibia fractures. The level of physical activities appears permanently reduced in most patients. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  2. Initial outcome and efficacy of S3 proximal humerus locking plate in the treatment of proximal humerus fractures

    International Nuclear Information System (INIS)

    Zhang Zhiming; Zhu Xuesong; Bao Zhaohua; Yang Huilin

    2012-01-01

    Objective: to explore the initial outcome and efficacy of S 3 proximal humerus locking plate in the treatment of proximal humerus fractures. Methods: Twenty-two patients with proximal humerus fracture were treated with the S 3 proximal humerus locking plate. Most of the fractures were complex, two-part (n=4), three-part (n=11) and four-part (n=7) fractures according to the Neer classification of the proximal humerus fractures. Results: All patients were followed up for 3∼15 months. There were no complications related to the implant including loosening or breakage of the plate. Good and excellent results were documented in 17 patients fair results in 4 patients according the Neer scores of shoulder. Conclusion: New design concepts of S 3 proximal humerus plate provide the subchondral support and the internal fixation support. With the addition of the proper exercise of the shoulder joint, the outcomes would be satisfied. (authors)

  3. Technical Errors May Affect Accuracy of Torque Limiter in Locking Plate Osteosynthesis.

    Science.gov (United States)

    Savin, David D; Lee, Simon; Bohnenkamp, Frank C; Pastor, Andrew; Garapati, Rajeev; Goldberg, Benjamin A

    2016-01-01

    In locking plate osteosynthesis, proper surgical technique is crucial in reducing potential pitfalls, and use of a torque limiter makes it possible to control insertion torque. We conducted a study of the ways in which different techniques can alter the accuracy of torque limiters. We tested 22 torque limiters (1.5 Nm) for accuracy using hand and power tools under different rotational scenarios: hand power at low and high velocity and drill power at low and high velocity. We recorded the maximum torque reached after each torque-limiting event. Use of torque limiters under hand power at low velocity and high velocity resulted in significantly (P torque and subsequent complications. For torque limiters, the most reliable technique involves hand power at slow velocity or drill power with careful control of insertion speed until 1 torque-limiting event occurs.

  4. A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation A study on synthetic bones

    Directory of Open Access Journals (Sweden)

    Korhan Ozkan

    2015-01-01

    Conclusion: The proximal femoral intramedullary nail provides more stability and allows for earlier weight bearing than the locking plate when used for the treatment of unstable intertrochanteric fractures of the femur. Clinicians should be cautious for early weight bearing with locking plate for unstable intertrochanteric femur fractures.

  5. Locking compression plate osteosynthesis of complicated mandibular fractures in six horses.

    Science.gov (United States)

    Kuemmerle, J M; Kummer, M; Auer, J A; Nitzl, D; Fürst, A E

    2009-01-01

    Complicated mandibular fractures were recognised in one foal, one pony and four horses. The foal was two months old while the adult animals ranged in age from 12 to 24 years. Three horses had a unilateral horizontal ramus fracture. Two fractures were open and one was closed. Comminution was present in one of these patients while the other two horses had marked displacement of the fragments. Two suffered from comminuted fractures of the horizontal and vertical ramus of the mandible. One of these patients had open and infected fractures. One foal had a bilateral horizontal ramus fracture with marked periosteal 'new bone' formation and malalignement which required corrective osteotomy. Each horse underwent locking compression plate (LCP) osteosynthesis consisting of open fracture reduction and application of one to three 4.5/5.0 mm LCP at the ventral, lateral or caudal aspect of the mandible under fluoroscopic control. Two 3.5 mm LCP were used in the foal. Plate fixation was supported by application of a cerclage wire construct between the incisor and premolar teeth in most patients. Complete fracture healing, with an excellent functional and cosmetic outcome, was achieved in all of the patients. Complications encountered included seroma formation, screw and wire breakage, as well as implant and apical tooth root infections. The LCP was removed after fracture healing had occurred in four patients.

  6. Fixation of supraglenoid tubercle fractures using distal femoral locking plates in three Warmblood horses.

    Science.gov (United States)

    Frei, Sina; Fürst, Anton E; Sacks, Murielle; Bischofberger, Andrea S

    2016-05-18

    Three horses that were presented with supraglenoid tubercle fractures were treated with open reduction and internal fixation using distal femoral locking plates (DFLP). Placing the DFLP caudal to the scapular spine in order to preserve the suprascapular nerve led to a stable fixation, however, it resulted in infraspinatus muscle atrophy and mild scapulohumeral joint instability (case 1). Placing the DFLP cranial to the scapular spine and under the suprascapular nerve resulted in a stable fixation, however, it resulted in severe atrophy of the supraspinatus and infraspinatus muscles and scapulohumeral joint instability (case 2). Placing the DFLP cranial to the scapular spine and slightly overbending it at the suprascapular nerve passage site resulted in the best outcome (case 3). Only a mild degree of supraspinatus and infraspinatus muscle atrophy was apparent, which resolved quickly and with no effect on scapulohumeral joint stability. In all cases, fixation of supraglenoid tubercle fractures using DFLP in slightly different techniques led to stable fixations with good long-term outcome. One case suffered from a mild incisional infection and plates were removed in two horses. Placement of the DFLP cranial to the scapular spine and slightly overbending it at the suprascapular nerve passage prevented major nerve damage. Further cases investigating the degree of muscle atrophy following the use of the DFLP placed in the above-described technique are justified to improve patient outcome.

  7. SURGICAL MANAGEMENT OF TRAUMATIC MANUBRIO-STERNAL DISLOCATION WITH LOCKING COMPRESSION PLATE; A CASE REPORT AND REVIEW OF LITERATURE

    Directory of Open Access Journals (Sweden)

    FAREED AHMED SHAIKH

    2017-05-01

    Full Text Available Background: Manubriosternal joint dislocation as a result of trauma is rare with only few case reports published in literature. Materials that have been used for fixation of displaced manubriosternal joint are steel wires, polydioxanone ropes, and plates with screws. Case: We present a case of manubriosternal dislocation in which fixation was done with locking compression plate. This is a case of 32 years old lady with history of road traffic accident, car ran over her chest. She had bilateral lung contusions with multiple rib fractures on right side and manubriosternal joint dislocation of type-I. Patient was initially stabilized in high dependency unit, and once her contusions got better, she underwent fixation of her manubriosternal dislocation with locking compression plate. Post-operatively she remained pain free and was discharged home. Conclusion: This case is an important addition to literature regarding options that can be used for fixation of manubriosternal joint dislocation.

  8. Evaluation of locked plate in the osteosynthesis of fractures in osteoporotic bones.

    Science.gov (United States)

    Oboirien, Muhammad; Agbo, Stephen Patrick; Ajiboye, Lukman Olalekan

    2017-01-01

    The use of conventional dynamic compression plates (DCPs) in osteoporotic bones is associated with higher chances of implant failure. The advent and use of locking combi-plates have ensured a stable construct during osteosynthesis of fractures in osteoporotic bones. The study aims to assess the outcome of use of locking combi-plates in the management of fractures in osteoporotic bones in our environment. Cases of patients with nonunion and localized osteoporosis from January 2014 to December 2014 that were managed with locked combi-plates were reviewed. Outcome was assessed by time to healing, stability of implant construct after 6 and 12 months. There were 10 patients with mean age of 47.4 ± 12.63 years. There were 9 males and 1 female, and road traffic crashes were the mechanism of injury in 90% (n = 9) and gunshot injuries in 10% (n = 1). Atrophic nonunion was the most common indication for osteosynthesis with 80%, followed by fibrous nonunion with 10.0%. The humerus was the most common long bone involved with 50%. Locked broad DCP was used in 62.5%, and the duration between initial injury and surgery was 6 and 48 months, with an average of 17.5 months. The outcome was such that 90% healed after 12 months on follow-up while one case had the implant backing out and delay union at 6 months. The use of locked plate in the management of nonunion in the presence of osteoporosis ensures stable fixation construct and healing. Contexte: L'utilisation de plaques de compression dynamiques conventionnelles dans les os ostéoporotiques est associée à des chances plus élevées de défaillance de l'implant. L'avènement et l'utilisation de combi-plaques de verrouillage ont assuré une construction stable lors de l'ostéosyntheis de fractures dans les os ostéoporotiques. Objectifs: L'étude vise à évaluer le résultat de l'utilisation de combi-plaques de verrouillage dans la gestion des fractures dans les os ostéoporotiques dans notre environnement. Méthodologie: Les

  9. Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study.

    Science.gov (United States)

    Chen, Pengbo; Lu, Hua; Shen, Hao; Wang, Wei; Ni, Binbin; Chen, Jishizhan

    2017-02-23

    Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. Three different 3D finite element models of the lateral tibial plateau fracture with the bone plates were created. Various axial forces (100, 500, 1000, and 1500 N) were applied to simulate the axial compressive load on an adult knee during daily life. The equivalent maps of displacement and stress were output, and relative displacement was calculated along the fracture lines. The displacement and stresses in the fixation complexes increased with the axial force. The equivalent displacement or stress map of each fixation under different axial forces showed similar distributing characteristics. The motion characteristics of the three models differed, and the max-shear stress of trabecula increased with the axial load. These two novel plates could fix lateral tibial plateau fractures involving anterolateral and posterolateral fragments. Motions after open reduction and stable internal fixation should be advised to decrease the risk of trabecular microfracture. The relative displacement of the posterolateral fragments is different when using anterolateral plate and posterolateral plate, which should be considered in choosing the implants for different posterolateral plateau fractures.

  10. The Clinical and Economic Impact of Generic Locking Plate Utilization at a Level II Trauma Center.

    Science.gov (United States)

    Mcphillamy, Austin; Gurnea, Taylor P; Moody, Alastair E; Kurnik, Christopher G; Lu, Minggen

    2016-12-01

    In today's climate of cost containment and fiscal responsibility, generic implant alternatives represent an interesting area of untapped resources. As patents have expired on many commonly used trauma implants, generic alternatives have recently become available from a variety of sources. The purpose of this study was to examine the clinical and economic impact of a cost containment program using high quality, generic orthopaedic locking plates. The implants available for study were anatomically precontoured plates for the clavicle, proximal humerus, distal radius, proximal tibia, distal tibia, and distal fibula. Retrospective review. Level II Trauma center. 828 adult patients with operatively managed clavicle, proximal humerus, distal radius, proximal tibia, tibial pilon, and ankle fractures. Operative treatment with conventional or generic implants. The 414 patients treated with generic implants were compared with 414 patients treated with conventional implants. There were no significant differences in age, sex, presence of diabetes, smoking history or fracture type between the generic and conventional groups. No difference in operative time, estimated blood loss or intraoperative complication rate was observed. No increase in postoperative infection rate, hardware failure, hardware loosening, malunion, nonunion or need for hardware removal was noted. Overall, our hospital realized a 56% reduction in implant costs, an average savings of $1197 per case, and a total savings of $458,080 for the study period. Use of generic orthopaedic implants has been successful at our institution, providing equivalent clinical outcomes while significantly reducing implant expenditures. Based on our data, the use of generic implants has the potential to markedly reduce operative costs as long as quality products are used. Therapeutic Level III.

  11. Treatment of Unstable Trochanteric Femur Fractures: Proximal Femur Nail Versus Proximal Femur Locking Compression Plate.

    Science.gov (United States)

    Singh, Ashutosh Kumar; Narsaria, Nidi; G R, Arun; Srivastava, Vivek

    Unstable trochanteric femur fractures are common fractures that are difficult to manage. We conducted a prospective study to compare functional outcomes and complications of 2 different implant designs, proximal femur nail (PFN) and proximal femur locking compression plate (PFLCP), used in internal fixation of unstable trochanteric femur fractures. On hospital admission, 48 patients with unstable trochanteric fractures were randomly assigned (using a sealed envelope method) to treatment with either PFN (24 patients) or PFLCP (24 patients). Perioperative data and complications were recorded. All cases were followed up for 2 years. The groups did not differ significantly (P > .05) in operative time, reduction quality, complications, hospital length of stay, union rate, or time to union. Compared with the PFLCP group, the PFN group had shorter incisions and less blood loss. Regarding functional outcomes, there was no significant difference in mean Harris Hip Score (P = .48) or Palmer and Parker mobility score (P = .58). Both PFN and PFLCP are effective in internal fixation of unstable trochanteric femur fractures.

  12. Use of locking compression plates in ulnar fractures of 18 horses.

    Science.gov (United States)

    Jacobs, Carrie C; Levine, David G; Richardson, Dean W

    2017-02-01

    To describe the outcome, clinical findings, and complications associated with the use of the locking compression plate (LCP) for various types of ulnar fractures in horses. Retrospective case series. Client owned horses (n = 18). Medical records, radiographs, and follow-up for horses having an ulnar fracture repaired using at least 1 LCP were reviewed. Fifteen of 18 horses had fractures of the ulna only, and 3 horses had fractures of the ulna and proximal radius. All 18 horses were discharged from the hospital. Complications occurred in 5 horses; incisional infection (n = 4, 22%), implant-associated infection (n = 2, 11%), and colic (n = 1, 6%). Follow-up was available for all horses at a range of 13-120 months and 15 horses (83%) were sound for their intended purpose and 3 horses (17%) were euthanatized. One horse was euthanatized for complications associated with original injury and surgery. The LCP is a viable method of internal fixation for various types of ulnar fractures, with most horses in this series returning to soundness. © 2017 The American College of Veterinary Surgeons.

  13. Quantification of defects depth in glass fiber reinforced plastic plate by infrared lock-in thermography

    Energy Technology Data Exchange (ETDEWEB)

    Ranjit, Shrestha; Kim, Won Tae [Kongju National University, Cheonan (Korea, Republic of); Choi, Man Yong [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2016-03-15

    The increasing use of composite materials in various industries has evidenced the need for development of more effective nondestructive evaluation methodologies in order to reduce rejected parts and to optimize production cost. Infrared thermography is a noncontact, fast and reliable non-destructive evaluation technique that has received vast and growing attention for diagnostic and monitoring in the recent years. This paper describes the quantitative analysis of artificial defects in Glass fiber reinforced plastic plate by using Lockin infrared thermography. The experimental analysis was performed at several excitation frequencies to investigate the sample ranging from 2.946 Hz down to 0.019 Hz and the effects of each excitation frequency on defect detachability. The four point method was used in post processing of every pixel of thermal images using the MATLAB programming language. The relationship between the phase contrast with defects depth and area was examined. Finally, phase contrast method was used to calculate the defects depth considering the thermal diffusivity of the material being inspected and the excitation frequency for which the defect becomes visible. The obtained results demonstrated the effectiveness of Lock-in infrared thermography as a powerful measurement technique for the inspection of Glass fiber reinforced plastic structures.

  14. Biomechanical testing of a hybrid locking plate fixation of equine sesamoid osteotomies.

    Science.gov (United States)

    Almeida da Silveira, E; Levasseur, A; Lacourt, M; Elce, Y; Petit, Y

    2014-01-01

    To compare the biomechanical properties of a hybrid locking compression plate (LCP) construct with the compression screw technique as a treatment for transverse mid-body proximal sesamoid bone fractures. Ten paired forelimbs from abattoir horses were used. The medial proximal sesamoid bone of each limb was osteotomized transversely and randomly assigned, to either repair with a two-hole 3.5 mm LCP or a 4.5 mm cortical screw placed in lag fashion. Each limb was tested biomechanically by axial loading in single cycle until failure. The point of failure was evaluated from the load-displacement curves. Then a gross evaluation and radiographs were performed to identify the mode of failure. The loads to failure of limbs repaired with the hybrid LCP construct (4968 N ± 2167) and the limbs repaired with the screw technique (3009 N ± 1091) were significantly different (p fracture of the apical fragment of the proximal sesamoid bone. The LCP technique has potential to achieve a better fracture stability and healing when applied to mid-body fractures of the proximal sesamoid bone. Further testing, particularly fatigue resistance is required to corroborate its potential as a treatment option for mid-body fractures of the proximal sesamoid bone.

  15. Application of Minimally Invasive Treatment of Locking Compression Plate in Schatzker Ⅰ-Ⅲ Tibial Plateau Fracture

    OpenAIRE

    Guohui Zhao

    2014-01-01

    Objective: To investigate the clinical effect of minimally invasive treatment of locking compression plate (LCP) in Schatzker Ⅰ-Ⅲ tibial plateau fracture. Methods: Thirty-eight patients with Schatzker Ⅰ-Ⅲ tibial plateau fracture in our hospital were given minimally invasive treatment of LCP, and the artificial bone was transplanted to the depressed bone. Adverse responses, wound healing time and clinical efficacy were observed. Results: All patients were followed-up for 14- 20 months, and the...

  16. Treatment of Displaced Sacroiliac Fracture Using the Lateral Window for Short Plate Buttress Reduction and Percutaneous Sacroiliac Screw Fixation.

    Directory of Open Access Journals (Sweden)

    Colin Murphy

    2016-04-01

    Full Text Available Fractures through the sacroiliac joint are very challenging to treat, technically difficult to reduce through closed methods on account of the multiaxial displacement of fractures fragments, frequently occur in very unwell patients, and have poor outcomes if malreduction is present. We describe a technique utilising the lateral window and a short buttress plate to reduce and stabilize the fragments prior to percutaneous fixation with sacroiliac screws.

  17. FUNCTIONAL OUTCOME OF SUPRACONDYLAR FRACTURES OF FEMUR MANAGED BY OPEN REDUCTION AND INTERNAL FIXATION WITH LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    Madhusudhana

    2015-10-01

    Full Text Available INTRODUCTION : Incidence of distal femur fractures is approximately 37 per 1 , 00,000 person - years.¹Distal femoral fractures has two different injury mechanisms, high energy trauma and low energy trauma. In high - energy trauma, the problem of restoring the function in a destroyed knee joint persists. Complex knee ligament injuries frequently occur additionally to extensive cartilage injuries. In elderly patients, extreme osteoporosis represents a particular problem for anchoring the implant. 2 Supracondylar and inter condylar fractures often are unstable and comminuted and tend to occur in the elderly or those with multiple injuries. Treatment options are many with varied results. The final outcome would depend upon the type of fracture, stabilization of fixation and and perhaps patient general condition. 3 The options for operative treatment are traditional plating techniques that require compression of the implant to the femoral shaft (blade plate, Dynamic Condylar Screw, non - locking condylar buttress plate, antegrade nailing fixation, retrograde nailing, sub muscular locked internal fixation and external fixation. 4 However, as the complexity of fractures needing treatment has changed from simple extra - articular supra - condylar types to inter - condylar and metaphyseal comminuted types, these implants may not be ideal. Double plating, and more recently, locked plating techniques have been advocated 5 . However with double plating there is often extensive soft tissue stripping on both sides of the femur, resulting in reduced blood supply and potential non - union and failure of the implants 6 . The LCP is a single beam construct where the strength of its fixation is equal to the sum of all screw - bone interfaces rather than a single screw’s axial stiffness or pullout resistance as seen in unlocked plates 7,8 . Its unique biomechanical function is based on splinting rather than compression resulting in flexible stabilization

  18. [Treatment of complex tibial plateau fractures with bilateral locking plate and bone graft].

    Science.gov (United States)

    Yan, Ying-Jie; Cheng, Zhan-Wei; Feng, Kai; Yan, Shao-Hua

    2012-07-01

    To explore the effective methods for the treatment of complex tibial plateau fractures. From May 2008 to April 2011, 28 patients with complex tibial plateau fractures were treated indirect reduction techniques, bilateral locking plate fixation combined with autologous bone grafts. There were 21 males and 7 females, with an average age of 43 years ranging from 21 to 65. There were 11 cases in Schatzker type V, 17 in VI. The effect was evaluated by Rasmussen standard on clinical and radiological. All patients were followed-up for 7 to 36 months (averaged of 21.5 months). Healing time of fracture was from 3 to 8 months (averaged 5.5 months). The results of Rasmussen scores in clinical was 4.50 +/- 1.32 in pain, 4.32 +/- 1.63 in walking ability, 4.07 +/- 1.34 in knee activity, 4.78 +/- 1.27 in stability of the knee, 4.85 +/- 1.12 in stretch knee; the results in radiation was 5.07 +/- 0.92 in articular surface collapse, 5.00 +/- 0.98 in platform widened, 5.14 +/- 0.85 in knee external varus. The effect result was excellent in 8 cases, good in 15, fair in 3 and poor in 2. The key for the treatment of complex tibial plateau fractures was to fully assess the damage as much as possible to protect the soft tissue, select the appropriate timing of surgery and surgical incision, application of indirect reduction techniques, limited incision and effective internal fixation to restore joint surface smooth and good limb alignment, early exercise, in order to achieve maximum recovery of joint function.

  19. Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.

    Science.gov (United States)

    Burkhart, Klaus Josef; Mueller, Lars P; Krezdorn, David; Appelmann, Philipp; Prommersberger, Karl J; Sternstein, Werner; Rommens, Pol M

    2007-12-01

    Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs. Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0-mm radial head plate. Implants were tested under axial (N/mm) and torsional (Ncm/ degrees ) loads with a servohydraulic materials testing machine. The radial head plate was significantly stiffer than all other implants under axial as well as under torsional loads, with values of 36 N/mm and 13 Ncm/ degrees . The second-stiffest implant was the blade plate, with values of 20 N/mm and 6 Ncm/ degrees . The weakest implants were the 2.0-mm LCP, with values of 6 N/mm and 2 Ncm/ degrees , and the 2.0-mm crossed screws, with values of 18 N/mm and 2 Ncm/ degrees . The 2.4-mm T plate, with values of 14 N/mm and 4 Ncm/ degrees , and the 2.0-mm grid plate, with values of 8 N/mm and 4 Ncm/ degrees came to lie in the midfield. The 2.0-mm angle-stable plates-depending on their design-allow fixation with comparable or even higher stability than the bulky 2.4-mm nonlocking implants and 2.0-mm crossed screws.

  20. PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures.

    Science.gov (United States)

    Schliemann, Benedikt; Seifert, Robert; Theisen, Christina; Gehweiler, Dominic; Wähnert, Dirk; Schulze, Martin; Raschke, Michael J; Weimann, Andre

    2017-01-01

    The high rigidity of metal implants may be a cause of failure after fixation of proximal humerus fractures. Carbon fiber-reinforced polyetheretherketone (PEEK) plates with a modulus similar to human cortical bone may help to overcome this problem. The present study assesses the biomechanical behavior of a PEEK plate compared with a titanium locking plate. Unstable two- and three-part fractures were simulated in 12 pairs of cadaveric humeri and were fixed with either a PEEK or a titanium locking plate using a pairwise comparison. With an optical motion capture system, the stiffness, failure load, plate bending, and the relative motion at the bone-implant interface and at the fracture site were evaluated. The mean load to failure for two- and three-part fracture fixations was, respectively, 191 N (range 102-356 N) and 142 N (range 102-169 N) in the PEEK plate group compared with 286 N (range 191-395 N) and 258 N (range 155-366 N) in the titanium locking plate group. The PEEK plate showed significantly more bending in both the two- and three-part fractures (p PEEK plate showed lower fixation strength and increased motion at the bone-implant interface compared with a titanium locking plate.

  1. Effect of screw position on single cycle to failure in bending and torsion of a locking plate-rod construct in a synthetic feline femoral gap model.

    Science.gov (United States)

    Niederhäuser, Simone K; Tepic, Slobodan; Weber, Urs T

    2015-05-01

    To evaluate the effect of screw position on strength and stiffness of a combination locking plate-rod construct in a synthetic feline femoral gap model. 30 synthetic long-bone models derived from beechwood and balsa wood. 3 constructs (2 locking plate-rod constructs and 1 locking plate construct; 10 specimens/construct) were tested in a diaphyseal bridge plating configuration by use of 4-point bending and torsion. Variables included screw position (near the fracture gap and far from the fracture gap) and application of an intramedullary pin. Constructs were tested to failure in each loading mode to determine strength and stiffness. Failure was defined as plastic deformation of the plate or breakage of the bone model or plate. Strength, yield angle, and stiffness were compared by use of a Wilcoxon test. Placement of screws near the fracture gap did not increase bending or torsional stiffness in the locking plate-rod constructs, assuming the plate was placed on the tension side of the bone. Addition of an intramedullary pin resulted in a significant increase in bending strength of the construct. Screw positioning did not have a significant effect on any torsion variables. Results of this study suggested that, in the investigated plate-rod construct, screw insertion adjacent to the fracture lacked mechanical advantages over screw insertion at the plate ends. For surgeons attempting to minimize soft tissue dissection, the decision to make additional incisions for screw placement should be considered with even more caution.

  2. High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate.

    Science.gov (United States)

    Wirtz, C; Abbassi, F; Evangelopoulos, D S; Kohl, S; Siebenrock, K A; Krüger, A

    2013-06-01

    Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. Early results for PF-LCP osteosynthesis show major

  3. [Treatment type C fracture of the distal radius with locking compression plate and external fixators].

    Science.gov (United States)

    Yang, Xiang; Zhao, You-ming; Chen, Lin; Ye, Cong-cong; Guo, Wei-jun; Wang, Bo

    2013-12-01

    To compare efficacy of unilateral external fixators and locking compression plates in treating type C fractures of the distal radius. From January 2009 to June 2010, 76 patients with distal radius fracture were treated with LCP and external fixators, 54 patients were followed up. Among them, 29 cases were male and 25 cases were female with an average age of 45.31 (ranged, 24 to 68) years old. There were 29 patients in LCP group. According to AO classification, 8 cases were type C1, 7 cases were type C2 and 14 cases were type C3. There were 25 cases in external fixators group. According to AO classification, 6 cases were type C1, 8 cases were type C2 and 11 cases were type C3. Radial height, volar tilt and radial inclination were compared, advanced Gartland-Werley scoring were used to assessed wrist joint function after 6 and 12 months' following up. Two cases were suffered from nail infection in external fixators group. Fifty-four patients were followed up from 12 to 24 months with an average of 21.3 months. Radial height was (9.60 +/- 0.72) mm, volar tilt was (9.55 +/- 0.80) degrees and radial inclination was (21.40 +/- 0.78) degrees in LCP group,while those were (9.40 +/- 0.70) mm, (9.47 +/- 0.71) degrees and (21.20 +/- 0.73) degrees in external fixtors group, and with no statistical significance (P>0.05). Advanced Gartland-Werley score after 6 months' following up was 3.31 +/- 1.17 in LCP group, 5.56 +/- 1.58 in external fixtors group, and with significant difference (t=-5.99,Pmeaning (t=-1.55, P>0.05). LCP and external fixtors can receive good curative effects in treating type C distal radius fracture, and LCP can obtain obviously short-term efficacy, while there is no significant difference between two groups in long-term results. For serious distal radius comminuted fracture which unable to plate internal fixation, external fixators is a better choice.

  4. Clinical comparative analysis on unstable pelvic fractures in the treatment with percutaneous sacroiliac screws and sacroiliac joint anterior plate fixation.

    Science.gov (United States)

    Li, C-L

    2014-01-01

    To investigate clinical efficacy of unstable pelvic fractures in the treatment with percutaneous sacroiliac screws and sacroiliac joint anterior plate fixation. 64 patients with unstable pelvic fractures were selected in the hospital from January 2008 to June 2011, and were randomly divided into two groups.(32 patients with sacroiliac anterior plate fixation as the control group, and another 32 patients with percutaneous sacroiliac screw internal fixation as the observation group). The perioperative period clinical indicators, postoperative Matta score, postoperative Majeed function score of all patients were compared and analyzed. The operation time, intraoperative blood loss, wound total length, postoperative fever time, duration of hospitalization in the observation group were significantly less than those in the control group. The complication rate (3.1%) in the observation group was lower than that in the control group (21.9%). The rate of Matta score excellent (96.9%) in the observation group was higher than that in the control group (81.2%) after the treatment. The rate of Majeed function score excellent (93.8%) in the observation group was significantly higher than that in the control group (75%) after the treatment. Percutaneous sacroiliac screw internal fixation in the treatment of unstable pelvic fractures has less injury, less bleeding, less pain and rapid recovery which is a safe and effective minimally invasive operation method. The clinical curative effect of percutaneous sacroiliac screw internal fixation is better than anterior plate fixation for the treatment of sacroiliac joint. The full preparation before the surgery and patients with positive can substantially reduce the occurrence of complications rate.

  5. Plate rotations, fault slip rates, fault locking, and distributed deformation in northern Central America from 1999-2017 GPS observations

    Science.gov (United States)

    Ellis, A. P.; DeMets, C.; Briole, P.; Cosenza, B.; Flores, O.; Guzman-Speziale, M.; Hernandez, D.; Kostoglodov, V.; La Femina, P. C.; Lord, N. E.; Lasserre, C.; Lyon-Caen, H.; McCaffrey, R.; Molina, E.; Rodriguez, M.; Staller, A.; Rogers, R.

    2017-12-01

    We describe plate rotations, fault slip rates, and fault locking estimated from a new 100-station GPS velocity field at the western end of the Caribbean plate, where the Motagua-Polochic fault zone, Middle America trench, and Central America volcanic arc faults converge. In northern Central America, fifty-one upper-plate earthquakes caused approximately 40,000 fatalities since 1900. The proximity of main population centers to these destructive earthquakes and the resulting loss of human life provide strong motivation for studying the present-day tectonics of Central America. Plate rotations, fault slip rates, and deformation are quantified via a two-stage inversion of daily GPS position time series using TDEFNODE modeling software. In the first stage, transient deformation associated with three M>7 earthquakes in 2009 and 2012 is estimated and removed from the GPS position time series. In Stage 2, linear velocities determined from the corrected GPS time series are inverted to estimate deformation within the western Caribbean plate, slip rates along the Motagua-Polochic faults and faults in the Central America volcanic arc, and the gradient of extension in the Honduras-Guatemala wedge. Major outcomes of the second inversion include the following: (1) Confirmation that slip rates on the Motagua fault decrease from 17-18 mm/yr at its eastern end to 0-5 mm/yr at its western end, in accord with previous results. (2) A transition from moderate subduction zone locking offshore from southern Mexico and parts of southern Guatemala to weak or zero coupling offshore from El Salvador and parts of Nicaragua along the Middle America trench. (3) Evidence for significant east-west extension in southern Guatemala between the Motagua fault and volcanic arc. Our study also shows evidence for creep on the eastern Motagua fault that diminishes westward along the North America-Caribbean plate boundary.

  6. Distraction osteogenesis using combined locking plate and Ilizarov fixator in the treatment of bone defect: A report of 2 cases

    Directory of Open Access Journals (Sweden)

    John Mukhopadhaya

    2017-01-01

    Full Text Available Distraction osteogenesis and bone transport has been used to reconstruct bone loss defect by allowing new bone to form in the gap. Plate-guided bone transport has been successfully described in literature to treat bone loss defect in the femur, tibia, and mandible. This study reports two cases of fracture of femur with segmental bone loss treated with locking plate fixation and bone transport with Ilizarov ring fixator. At the time of docking, when the transport segment is compressed with bone fragment, the bone fragment is fixed with additional locking or nonlocking screws through the plate. The bone defect size was 7 cm in case 1 and 8 cm in case 2 and the external fixation indexes were 12.7 days/cm and 14 days/cm. No shortening was present in either of our cases. The average radiographic consolidation index was 37 days/cm. Both cases achieved infection-free bone segment regeneration and satisfactorily functional outcome. This technique reduces the duration of external fixation during the consolidation phase, allows correction of length and alignment and provides earlier rehabilitation.

  7. The Use of the String of Pearls Locking Plate System in the Stabilisation of a Comminuted Calcaneal Fracture in a Giant Breed Dog

    Directory of Open Access Journals (Sweden)

    A. B. Scrimgeour

    2011-01-01

    Full Text Available An eight-year-old male Pyrenean mountain dog was presented with a comminuted fracture of the right calcaneus following motor vehicle trauma. The fracture was stabilised with a plate-rod construct, using the String of Pearls locking plate system and an intramedullary pin. Healing was uncomplicated.

  8. Locking plate versus external fixation for type C distal radius fractures: A meta-analysis of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Dong Wang

    2018-04-01

    Full Text Available Purpose: Distal radial fracture is one of the most common fractures. Up to now, locking plates (LP and external fixation (EF are two conventional surgical approaches to type C radius fracture. Which method is superior has not yet reached a consensus. We try to assess the clinical effectiveness of the two interventions by this meta-analysis. Methods: We used network to search the PubMed, Embase, and Cochrane Medical Library of randomized controlled clinical trials about the type C distal radius fractures performed according to the search strategy mentioned in Cochrane Handbook 5.1.0 from Jan. 2005 to Jan. 2016. Patients in the experimental group were used LP, in the control group were included EF and other surgical approaches. Publication language was restricted to English. Studies that patient population and surgical indication did not define had been excluded. Studies must report at least one of the outcomes as follow: radial inclination, palmar tilt, ulnar variance, range of wrist flexion and extension, and range of wrist supination and pronation. The trials in which participants included children were excluded. We used Jadad study scores to appraise the study. Results: Seven studies included 162 patients (LP group and 190 patients (EF group. We compared the radial inclination, palmar tilt, ulnar variance, range of wrist flexion and extension, and range of wrist supination and pronation. The radial inclination were revealed a difference favoring LP over EF [WMD = 1.84, 95% CI (0.17, 3.50, p = 0.03] and the palmar tilt and ulnar variance was no significant difference between the two groups [(WMD = 3.61, 95% CI (0.00, 7.23, p = 0.05; WMD = 0.05, 95% CI (−0.99, 1.09, p = 0.93]. The functional activities of range of flexion and extension and range of supination and pronation between the two groups was no difference [WMD = 10.04, 95% CI (−6.88, 26.96, p = 0.24; WMD = 12.53, 95% CI (−9.99, 35.06, p = 0.28]. Conclusion

  9. Benefits and harms of locking plate osteosynthesis in intraarticular (OTA Type C) fractures of the proximal humerus: A systematic review

    DEFF Research Database (Denmark)

    Brorson, Stig; Rasmussen, Jeppe Vejlgaard; Frich, Lars Henrik

    2012-01-01

    stable plates in AO/OTA Type C fractures of the proximal humerus. METHODS: We conducted an iterative search in PubMed, Embase, Cochrane Library, Web of Science, Cinahl, and PEDro in all languages from 1999 to November 2010. Eligible studies should study the outcome for Type C fractures after primary...... according to study type and synthesised qualitatively. No randomised clinical trials were identified. Two comparative, observational studies reported a mean CS of 71 (relative to contralateral shoulder) and 75 (non-adjusted Constant Score) for Type C fractures. For all studies mean non-adjusted CS ranged......INTRODUCTION: Locking plate osteosynthesis of proximal humeral fractures are widely recommended and used, even in complex intraarticular fracture patterns such as AO/OTA Type C fractures. We systematically reviewed clinical studies assessing the benefits and harms of osteosynthesis with angle...

  10. EVALUATION OF FUNCTIONAL OUTCOME AFTER OPEN REDUCTION AND INTERNAL FIXATION OF DISTAL FEMUR FRACTURES BY LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    L. Lokanadha Rao

    2016-09-01

    Full Text Available BACKGROUND In the supra and intercondylar fractures of femur particularly with intra articular extension, patient may develop stiffness of knee, shortening, rotational deformities, internal derangement of knee with instability, varus and valgus deformities which affect patient’s routine lifestyle. If these cases were treated with locking compression plate, the results obtained were successful, superior, timesaving providing early ambulation and least disability improving the functional outcome. MATERIALS AND METHODS This is a prospective interventional study. This study includes 25 supracondylar and intercondylar fractures of femur (both Muller’s Type ‘A’, Type B and Type ‘C’ fractures treated with open reduction and internal fixation by Locking Compression Plate in the Department of Orthopaedics, King George Hospital, Visakhapatnam from September 2013 to September 2015. There are 16 males and 9 females with age ranging from 20 to 80 years with an average of 44.6 years. Average age for males is 28.9 years and average age for females is 25 years. 18 fractures were due to road traffic accidents and 6 cases are due to fall from significant heights, 1 case due to simple fall from standing (osteoporosis. 15 cases were in right femur (60% and 10 cases were in left femur (40%. RESULTS 25 cases were included in the study. There is an increase in the rate of union, decreased time taken for union, increased knee range of motion, decreased time for weight-bearing, postoperative complications and duration for hospital stay. CONCLUSION LCP proved to be a good implant which could take the challenges like poor bone stock, severe comminution both metaphyseal and articular and prove successful. The locking head screws distally have prevented varus collapse, even in cases of osteoporosis. The Condylar LCP can be used in either an open or a minimally invasive manner.

  11. Biomechanical properties of orthogonal plate configuration versus parallel plate configuration using the same locking plate system for intra-articular distal humeral fractures under radial or ulnar column axial load.

    Science.gov (United States)

    Kudo, Toshiya; Hara, Akira; Iwase, Hideaki; Ichihara, Satoshi; Nagao, Masashi; Maruyama, Yuichiro; Kaneko, Kazuo

    2016-10-01

    Previous reports have questioned whether an orthogonal or parallel configuration is superior for distal humeral articular fractures. In previous clinical and biomechanical studies, implant failure of the posterolateral plate has been reported with orthogonal configurations; however, the reason for screw loosening in the posterolateral plate is unclear. The purpose of this study was to evaluate biomechanical properties and to clarify the causes of posterolateral plate loosening using a humeral fracture model under axial compression on the radial or ulnar column separately. And we changed only the plate set up: parallel or orthogonal. We used artificial bone to create an Association for the Study of Internal Fixation type 13-C2.3 intra-articular fracture model with a 1-cm supracondylar gap. We used an anatomically-preshaped distal humerus locking compression plate system (Synthes GmbH, Solothurn, Switzerland). Although this is originally an orthogonal plate system, we designed a mediolateral parallel configuration to use the contralateral medial plate instead of the posterolateral plate in the system. We calculated the stiffness of the radial and ulnar columns and anterior movement of the condylar fragment in the lateral view. The parallel configuration was superior to the orthogonal configuration regarding the stiffness of the radial column axial compression. There were significant differences between the two configurations regarding anterior movement of the capitellum during axial loading of the radial column. The posterolateral plate tended to bend anteriorly under axial compression compared with the medial or lateral plate. We believe that in the orthogonal configuration axial compression induced more anterior displacement of the capitellum than the trochlea, which eventually induced secondary fragment or screw dislocation on the posterolateral plate, or nonunion at the supracondylar level. In the parallel configuration, anterior movement of the capitellum or

  12. [Development and clinical application of a new type of anatomical locking plate for sternoclavicular joint fracture and dislocation].

    Science.gov (United States)

    Sun, Yuanlin; Yang, Yunkang; Ge, Jianhua; Yang, Kun; Xiang, Feifan; Zhou, Ju; Liang, Jie

    2018-03-01

    To report a new type of anatomical locking plate for sternocalvicular joint, and investigate its effectiveness in treatment of sternoclavicular joint fracture and dislocation. A new type of anatomical locking plate for sternoclavicular joint was developed, which accorded with the anatomical features and biomechanical characteristics of Chinese sternoclavicular joint. By adopting the method of clinical randomized controlled study, 32 patients with the sternoclavicular joint fracture and dislocation who met the selection criteria between June 2008 and May 2015 were randomly divided into groups A and B ( n =16), and the patients were treated with new anatomic locking plate and distal radial T locking plate internal fixation, respectively. There was no significant difference between 2 groups in gender, age, injured side, body mass index, cause of injury, type of injury, the time from injury to operation, and preoperative Rockwood grading score ( P >0.05). The operation time, intraoperative blood loss, incision length, hospitalization time, and postoperative complications in 2 groups were recorded, and the effectiveness was evaluated by Rockwood grading score. The operations of 2 groups completed successfully. The operation time, intraoperative blood loss, and hospitalization time in group A were significantly less than those in group B ( P case of sternoclavicular joint pain and 2 cases of wound infection; in group B, there were 1 case of sternoclavicular joint pain, 1 case of internal fixation loosening, and 1 case of sternoclavicular joint re-dislocation; there was no significant difference in complication incidence between 2 groups ( P =1.000). The Rockwood grading scores at each time point after operation in 2 groups were significantly higher than those before operation. At 1 month after operation, the Rockwood grading score in group A was significantly higher than that in group B ( t= 2.270, P =0.031); but there was no significant difference in the Rockwood

  13. Choosing a proper working length can improve the lifespan of locked plates. A biomechanical study.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2011-05-01

    It is hypothesized that the working length influences the implants fatigue behavior. However, few studies addressing this issue came to contrary results. Therefore, we tested systematically the influence of working length and implant material on the plate's endurance. We used an artificial model providing the substantial angle and length conditions of a human femur. A fracture gap of 10mm was bridged with identical shaped plate implants made of stainless steel and grade-2 titanium. The fatigue strength was tested for a short, medium and long working length. Aiming at an implant failure within 80,000 loading cycles the upper load threshold was set to 265N for the titanium plates and to 420N for the steel plates. The lower load threshold was -20N for both plates. For the steel plates there was no correlation between fatigue strength and working length. The construct stiffness did not differ at short and medium working length and was reduced by 10% (P=0.047) at long working length. For the titanium plates the fatigue strength tends to increase with the working length but this correlation was not significant (τ=0.417, P=0.051). Further there was a negative correlation between working length and construct stiffness (τ=0.552; P=0.01). The working length has no appreciable effect on the endurance of the steel plates. Compared to the grade 2-titanium plates the stainless steel plates sustain a larger amount of cyclic load. However, for the titanium plates a larger working length tends to improve the endurance. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. Close Intramedullary Interlocking Nailing Versus Locking Compression Plating In the Treatment of Closed Fracture Shaft of the Tibia.

    Science.gov (United States)

    Kundu, I K; Datta, N K; Chowdhury, A Z; Das, K P; Tarik, M M; Faisal, M A

    2016-07-01

    Fracture of tibial shaft is the commonest site of long bone fractures due to its superficial location involving young or middle-age people. Proper management is an important issue regarding the future effective movements. In this study patients were grouped in closed Intra medullary interlocking nailing and locking compression plating. Post-operative follow up at 2 weeks, 6 weeks, 12 weeks and 3 months thereafter up to 6 months were done. Each of the patients was evaluated clinically and radiologically by tucker criteria of Tuker et al. Patients were assessed for pain on full weight bearing and kneeling, shortening and range of motion of knee and ankle joints. Radiological assessment for union of fracture, alignment of fracture and angulations and position of nail and screws and infection were observed during follow up. A total number of 32 patients were selected but only 27 patients were available for follow up for a period of 6 months. They were grouped into Group A, consisting of 15 patients who took the treatment in the form of closed intramedullary interlocking nailing and Group B, consisting of 12 patients those underwent ORIF with locking compression plating. In both of the groups Motor Vehicle Accident was the main mechanism of trauma. Fracture involving the middle 3rd of the tibia is common in both the groups. During post-operative follow up, four patients in Group A complained anterior knee pain, one patient in Group B had superficial infection, most of the patients had no restriction of movement in the ankle and knee joints and a single patient in Group B showed 1.5cm shortening of the lower limb. Period of hospital stay and fracture union time were less in Group A, which was statistically significant. Both groups showed excellent result with minimum complications. So this study permits to conclude that close IM interlocking nailing and open reduction and internal fixation by locking compression plating is equally effective for the management of close

  15. [Comparison of clinical effect on locking plate for proximal humeral fracture with or without application of inferomedial screws].

    Science.gov (United States)

    Guo, Xiu-wu; Fan, Jian; Yuan, Feng

    2016-06-01

    To compare clinical outcomes of locking plate for proximal humeral fracture whether application of inferomedial screws. From January 2012 to July 2013, 46 patients with proximal humeral fracture underwent locking plates were retrospectively analyzed. There were 25 males and 21 females aged from 29 to 80 years old with an average of 55.1 years old. Among them, 25 patients were treated with inferomedial screws (support group), including 13 males and 12 females aged from 38 to 80 years old with an average of (55.8 ± 11.8) years old; 8 cases were part two fracture,10 cases were part three fracture and 7 cases were part four fracture according to Neer classification. Twenty-one patients were treated without inferomedial screws (non-support group), including 12 males and 9 females aged from 29 to 79 years old with an average of (54.2 ± 14.8)years old; 6 cases were part two fracture, 9 cases were part three fracture and 6 cases were part four fracture according to Neer classification. Operative time, fracture healing time and complications were observed and compared, Neer scoring of shoulder joint were used to evaluate clinical effect. All patients were followed up from 12 to 41 months with an average of 15.6 months. Operative time and fracture healing time in support group was (1.6 ± 0.4) h and (3.0 ± 0.6) months, and (1.5 ± 0.4) h and (3.1 ± 0.6) months in non-support group, while there was no statistical difference in operative time and fracture healing time between two groups. There was significant differences in Neer score between support group (89.7± 4.9) and non-support group (83.1 ± 7.1). No complication occurred in support group,while 4 cases occurred complications in non-support group. Locking plate with inferomedial screws for proximal humeral fracture has advantages of stable fixation, less complications, quick recovery of function and satisfied clinical effect.

  16. Proximal humeral fractures: the role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates.

    Science.gov (United States)

    Somasundaram, K; Huber, C P; Babu, V; Zadeh, H

    2013-04-01

    The aim of our study is to analyse the results of our surgical technique for the treatment of proximal humeral fractures and fracture dislocations using locking plates in conjunction with calcium sulphate bone-substitute augmentation and tuberosity repair using high-strength sutures. We used the extended deltoid-splitting approach for fracture patterns involving displacement of both lesser and greater tuberosities and for fracture-dislocations. Optimal surgical management of proximal humeral fractures remains controversial. Locking plates have become a popular method of fixation. However, failure of fixation may occur if they are used as the sole method of fixation in comminuted fractures, especially in osteopenic bone. We retrospectively analysed 22 proximal humeral fractures in 21 patients; 10 were male and 11 female with an average age of 64.6 years (range 37-77). Average follow-up was 24 months. Eleven of these fractures were exposed by the extended deltoid-splitting approach. Fractures were classified according to Neer and Hertel systems. Preoperative radiographs and computed tomography (CT) scans in three- and four-part fractures were done to assess the displacement and medial calcar length for predicting the humeral head vascularity. According to the Neer classification, there were five two-part, six three-part, five four-part fractures and six fracture-dislocations (two anterior and four posterior). Results were assessed clinically with disabilities of the arm, shoulder and hand (DASH) scores, modified Constant and Murley scores and serial postoperative radiographs. The mean DASH score was 16.18 and the modified Constant and Murley score was 64.04 at the last follow-up. Eighteen out of twenty-two cases achieved good clinical outcome. All the fractures united with no evidence of infection, failure of fixation, malunion, tuberosity failure, avascular necrosis or adverse reaction to calcium sulphate bone substitute. There was no evidence of axillary nerve

  17. Full title: Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures.

    Science.gov (United States)

    Mugnai, Raffaele; Tarallo, Luigi; Capra, Francesco; Catani, Fabio

    2018-05-25

    As the popularity of volar locked plate fixation for distal radius fractures has increased, so have the number and variety of implants, including variations in plate design, the size and angle of the screws, the locking screw mechanism, and the material of the plates. carbon-fiber reinforced polyetheretherketone (CFR-PEEK) plate features similar biomechanical properties to metallic plates, representing, therefore, an optimal alternative for the treatment of distal radius fractures. three different materials-composed plates were evaluated: stainless steel volar lateral column (Zimmer); titanium DVR (Hand Innovations); CFR-PEEK DiPHOS-RM (Lima Corporate). Six plates for each type were implanted in sawbones and an extra-articular rectangular osteotomy was created. Three plates for each material were tested for load to failure and bending stiffness in axial compression. Moreover, 3 constructs for each plate were evaluated after dynamically loading for 6000 cycles of fatigue. the mean bending stiffness pre-fatigue was significantly higher for the stainless steel plate. The titanium plate yielded the higher load to failure both pre and post fatigue. After cyclic loading, the bending stiffness increased by a mean of 24% for the stainless steel plate; 33% for the titanium; and 17% for the CFR-PEEK plate. The mean load to failure post-fatigue increased by a mean of 10% for the stainless steel and 14% for CFR-PEEK plates, whereas it decreased (-16%) for the titanium plate. Statistical analysis between groups reported significant values (p plastic deformation, and lower load to failure. N/A. Copyright © 2018. Published by Elsevier Masson SAS.

  18. Functional Outcomes After Temporary Bridging With Locking Plates in Lisfranc Injuries

    NARCIS (Netherlands)

    van Koperen, Paul J.; de Jong, Vincent M.; Luitse, Jan S. K.; Schepers, Tim

    2016-01-01

    The standard operative treatment of Lisfranc fracture dislocations currently consists of open reduction and transarticular fixation. Recently, bridge plating has been used more often. Using joint spanning, the reduced fracture dislocation is temporary stabilized to minimize articular damage. The

  19. Transduced for determining if steam generator tubes are locked in at support plate

    International Nuclear Information System (INIS)

    Hayes, J.K.

    1984-01-01

    A nuclear steam generator is described which includes a vessel, means to introduce vaporizable fluid into the bottom portion of the vessel, an outlet near the top through which vapor is discharged, a horizontal tube sheet extending across the vessel, a plurality of U-shaped tubes, having each end secured to and extending through the tube sheet, means for introducing heating fluid to one end of each of the U-shaped tubes, means for removing heating fluid from the other end of each of the U-shaped tubes, tube support means positioned within the vessel for preventing tube vibration, the tube support means including horizontally positioned means closely surrounding, but slightly spaced from each tube, means through which access can be had to the vessel interior beneath the tube sheet when the steam generator is not in operation, and testing means for determining whether or not a tube is locked into a tube support means including a longitudinal member, with a first end located inside the tube to be tested, and a second end located outside of the tube, means for securing the first end of the member to the inside of the tube, means for heating a length of the longitudinal member, and an equal length of the tube, to an elevated temperature, and means for indicating movement of the second end of the longitudinal member away from the tube end, which would indicate that the tube is locked into the support means

  20. Periprosthetic Vancouver type B1 and C fractures treated by locking-plate osteosynthesis

    DEFF Research Database (Denmark)

    Froberg, Lonnie; Troelsen, Anders; Brix, Michael

    2012-01-01

    Historically, the treatment of periprosthetic femoral fractures (PFFs) has been associated with a high frequency of complications and reoperations. The preferred treatment is internal fixation, a revision of the femoral stem, or a combination of both. An improved understanding of plate use during...

  1. Application of Minimally Invasive Treatment of Locking Compression Plate in Schatzker Ⅰ-Ⅲ Tibial Plateau Fracture

    Directory of Open Access Journals (Sweden)

    Guohui Zhao

    2014-06-01

    Full Text Available Objective: To investigate the clinical effect of minimally invasive treatment of locking compression plate (LCP in Schatzker Ⅰ-Ⅲ tibial plateau fracture. Methods: Thirty-eight patients with Schatzker Ⅰ-Ⅲ tibial plateau fracture in our hospital were given minimally invasive treatment of LCP, and the artificial bone was transplanted to the depressed bone. Adverse responses, wound healing time and clinical efficacy were observed. Results: All patients were followed-up for 14- 20 months, and the mean duration was 16 months. Within 1 week after operation, 1 patient suffered from short-term rejection reaction to artificial bone, but he healed after corresponding measures were taken. There were no complications like skin necrosis and externally-exposed steel plate among the patients. In addition, all fractures were recovered, and the recovery time was 2.6 - 4.1 months, with the mean duration being 3.4 months. The recovery of knee function was favorable, in which 20 cases were excellent, 14 were good, and 4 were general. The excellent and good rate was 89.5%. Conclusion: Minimally invasive treatment of LCP for Schatzker Ⅰ - Ⅲ tibial plateau fracture can reduce the postoperative relocation loss, and has small trauma and stable fixation.

  2. Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?

    Science.gov (United States)

    Königshausen, M; Kübler, L; Godry, H; Citak, M; Schildhauer, T A; Seybold, D

    2012-02-01

    The surgical treatment of displaced proximal humeral fractures (ORIF) is a perpetual challenge to the surgeon. For this reason, the principle of polyaxiality was developed to provide an improved primary stability of the fracture through better anchorage of the screws, especially in osteoporotic bone. The aim of this study was to present clinical results with the polyaxial locking plate in the operative treatment of proximal humerus fractures in order to determine whether the technique of polyaxiality leads to better functional outcome and lower complication rates in comparison to monoaxial plates in the literature. Seventy-three patients with displaced proximal humeral fractures were treated surgically with the polyaxial locking Suture Plate™ (Arthrex(®)) between 03/2007 and 06/2009. Fifty-two of the patients (mean age, 69.9 ± 12.1) were included in a radiographical and clinical examination using the Constant score (CS) and the Disabilities of the Arm, Shoulder and Hand score (DASH). The follow-up examinations were on average 13.9 ± 4.5 months (10-27 months) after surgical treatment. The mean CS of the patients was 66.0 ± 13.7 points, the age- and gender-related CS was 90.9% ± 20.0% and the mean DASH score was 23.8 ± 19.8 points for the injured side. The patients with a nearly anatomical reduction of their fracture (n = 13) reached a significantly higher CS (75.1 ± 8.5; p = 0.004) and DASH-score (13.6 ± 11.6; p = 0.043) and none of these patients had a complication. The complications were identified in 12 (23.1%) cases, 5 of which involved loss of reduction. All of these 5 cases were lacking of initial medial column support and 4 of which were type C2.3 AO-Classification. The data show that the combination of angular stability with the possibility of variable polyaxial screw direction is a good concept for reduction and fixation of displaced proximal humeral fractures, but anatomical reduction and medial support remain important preconditions for a good

  3. Indirect reduction technique using a distraction support in minimally invasive percutaneous plate osteosynthesis of tibial shaft fractures.

    Science.gov (United States)

    Dong, Wen-Wei; Shi, Zeng-Yuan; Liu, Zheng-Xin; Mao, Hai-Jiao

    2016-12-01

    To describe an indirect reduction technique during minimally invasive percutaneous plate osteosynthesis (MIPPO) of tibial shaft fractures with the use of a distraction support. Between March 2011 and October 2014, 52 patients with a mean age of 48 years (16-72 years) sustaining tibial shaft fractures were included. All the patients underwent MIPPO for the fractures using a distraction support prior to insertion of the plate. Fracture angular deformity was assessed by goni- ometer measurement on preoperative and postoperative images. Preoperative radiographs revealed a mean of 7.6°(1.2°-28°) angulation in coronal plane and a mean of 6.8°(0.5°-19°) angulation in sagittal plane. Postoperative anteroposterior and lateral radio- graphs showed a mean of 0.8°(0°-4.0°) and 0.6°(0°-3.6°) of varus/valgus and apex anterior/posterior angulation, respectively. No intraoperative or postoperative complications were noted. This study suggests that the distraction support during MIPPO of tibial shaft fractures is an effective and safe method with no associated complications.

  4. Fragment-Specific Fixation Versus Volar Locking Plates in Primarily Nonreducible or Secondarily Redisplaced Distal Radius Fractures: A Randomized Controlled Study.

    Science.gov (United States)

    Landgren, Marcus; Abramo, Antonio; Geijer, Mats; Kopylov, Philippe; Tägil, Magnus

    2017-03-01

    To compare the patient-reported, clinical, and radiographic outcome of 2 methods of internal fixation in distal radius fractures. Fifty patients, mean age 56 years (range, 21-69 years) with primarily nonreducible or secondarily redisplaced distal radius fractures were randomized to open reduction internal fixation using volar locking plates (n = 25) or fragment-specific fixation (n = 25). The patients were assessed on grip strength, range of motion, patient-reported outcome (Quick Disabilities of the Arm, Shoulder, and Hand), pain (visual analog scale), health-related quality of life (Short Form-12 [SF-12]), and radiographic evaluation. Grip strength at 12 months was the primary outcome measure. At 12 months, no difference was found in grip strength, which was 90% of the uninjured side in the volar plate group and 87% in the fragment-specific fixation group. No differences were found in range of motion and the median Quick Disabilities of the Arm, Shoulder, and Hand score was 5 in both groups. The overall complication rate was significant, 21% in the volar locking plate group, compared with 52% in the fragment-specific group. In treatment of primarily nonreducible or secondarily redisplaced distal radius fractures, volar locking plates and fragment-specific fixation both achieve good and similar patient-reported outcomes, although more complications were recorded in the fragment-specific group. Therapeutic II. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures.

    Science.gov (United States)

    Chen, Fancheng; Huang, Xiaowei; Ya, Yingsun; Ma, Fenfen; Qian, Zhi; Shi, Jifei; Guo, Shuolei; Yu, Baoqing

    2018-01-16

    Proximal tibia fractures are one of the most familiar fractures. Surgical approaches are usually needed for anatomical reduction. However, no single treatment method has been widely established as the standard care. Our present study aims to compare the stress and stability of intramedullary nails (IMN) fixation and double locking plate (DLP) fixation in the treatment of extra-articular proximal tibial fractures. A three-dimensional (3D) finite element model of the extra-articular proximal tibial fracture, whose 2-cm bone gap began 7 cm from the tibial plateau articular surface, was created fixed by different fixation implants. The axial compressive load on an adult knee during single-limb stance was imitated by an axial force of 2500 N with a distribution of 60% to the medial compartment, while the distal end was fixed effectively. The equivalent von Mises stress and displacement of the model was used as the output measures for analysis. The maximal equivalent von Mises stress value of the system in the IMN model was 293.23 MPa, which was higher comparing against that in the DLP fixation model (147.04 MPa). And the mean stress of the model in the IMN model (9.25 MPa) was higher than that of the DLP fixation system in terms of equivalent von Mises stress (EVMS) (P tibial fractures of young patients.

  6. Treatment of type 2 and 4 olecranon fractures with locking compression plate (LCP) osteosynthesis in horses: a prospective study (2002-2008)

    OpenAIRE

    Jackson, M; Kummer, M; Auer, J; Hagen, R; Fürst, A

    2011-01-01

    This prospective study describes a series of 18 olecranon fractures in 16 horses that were treated with locking compression plates (LCP). Twelve of the 18 fractures were simple (type 2), whereas six were comminuted (type 4). Six fractures were open and 12 were closed. Each horse underwent LCP osteosynthesis consisting of open reduction and application of one or two LCP. Complete fracture healing was achieved in 13 horses. Three horses had to be euthanatized: two because of severe infection an...

  7. MINIMUM INCISION PERCUTANEOUS PLATE OSTEOSYNTHESIS FOR DISTAL FIBULAR FRACTURES: A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Ramkumar Reddy

    2015-09-01

    Full Text Available Distal fibular fractures are usually communitted and most of the times osteoporotic especially if they are occurring in females and in geriatric age group. These fractures are usu ally associated with other fractures, which necessitates them to be fixed accurately. Owing to the fact that distal fragment is subcutaneous with scanty soft tissue over bone, which pose these fracture fixations become difficult by open methods in view of wound healing. A prospective study of 26 patients with distal fibular fractures were treated with MIPPO with hook plate were healed with less complications and better outcome. With this background we suggest a minimally invasive incision over proximal frag ment where sufficient soft tissue cover is present. From there pushing the special hook plate subperiosteally to distal fragment, hooking the tip of fibula and fixing the proximal fragment after reduction gives a simple and effective stable fixation

  8. Functional Recovery Following Pertrochanteric Hip Fractures Fixated with the Dynamic Hip Screw vs. the Percutaneous Compression Plate

    Directory of Open Access Journals (Sweden)

    Yocheved Laufer

    2005-01-01

    Full Text Available The Dynamic Hip Screw (DHS is currently the most frequently used implant for the treatment of pertrochanteric hip fractures. The Percutaneous Compression Plate (PCCP is a recently developed, alternative device that involves minimal invasive surgery. The objective of the present study was to compare functional recovery following these two surgical procedures. A total of 76 consecutive elderly subjects (mean age and standard deviation, 80.6 ± 5.5 following pertrochanteric hip fracture fixation were evaluated prospectively. Functional recovery was assessed 3 and 12 weeks and 2 years following surgery. Differences between groups 3 weeks postsurgery were found only in pain level during ambulation and in the weight-bearing capability of the operated extremity, which were both in favor of the PCCP. By 3 months, both groups had improved in all measures, but did not reach their preinjury level of independence. However, the PCCP group ambulated with fewer assistive devices and demonstrated better recovery of basic activities of daily living (BADL. While the majority of the subjects from both groups ambulated independently 2 years postsurgery, the PCCP group exhibited less pain during ambulation, was more independent in ADL, and required fewer assistive devices for ambulation. To summarize, the PCCP presents enhanced short- and long-term recovery of functional abilities in comparison to DHS. However, given the limited number of patients, further studies are necessary to substantiate these results.

  9. [Efficacy of Sacroiliac Joint Anterior Approach with Double Reconstruction Plate and Computer Assisted Navigation Percutaneous Sacroiliac Screw for Treating Tile C1 Pelvic Fractures].

    Science.gov (United States)

    Tan, Zhen; Fang, Yue; Zhang, Hui; Liu, Lei; Xiang, Zhou; Zhong, Gang; Huang, Fu-Guo; Wang, Guang-Lin

    2017-09-01

    To compare the efficacy of sacroiliac joint anterior approach with double reconstruction plate and computer assisted navigation percutaneous sacroiliac screw for treating Tile C1 pelvic fractures. Fifty patients with pelvic Tile C1 fractures were randomly divided into two groups ( n =25 for each) in the orthopedic department of West China Hospital of Sichuan University from December 2012 to November 2014. Patients in group A were treated by sacroiliac joint dislocation with anterior plate fixation. Patients in group B were treated with computerized navigation for percutaneous sacroiliac screw. The operation duration,intraoperative blood loss,incision length,and postoperative complications (nausea,vomiting,pulmonary infection,wound complications,etc.) were compared between the two groups. The postoperative fracture healing time,postoperative patient satisfaction,and postoperative fractures MATTA scores (to evaluate fracture reduction),postoperative MAJEED function scores,and SF36 scores of the patients were also recorded and compared. No significant differences in baseline characteristics were found between the two groups of patients. All of the patients in both groups had their operations successfully completed. Patients in group B had significantly shorter operations and lower intraoperative blood loss,incision length and postoperative complications than those in group A ( P 0.05). Sacroiliac joint anterior approach with double reconstruction plate and computer assisted navigation percutaneous sacroiliac screws are both effective for treating Tile C1type pelvic fractures,with similar longterm efficacies. However,computer assisted navigation percutaneous sacroiliac screw has the advantages of less trauma,less bleeding,and quicker.

  10. Advantage and limitations of a minimally-invasive approach and early weight bearing in the treatment of tibial shaft fractures with locking plates.

    Science.gov (United States)

    Adam, P; Bonnomet, F; Ehlinger, M

    2012-09-01

    Intramedullary nailing is a common method of treating tibial shaft fractures. However, precise control of reduction at the proximal and distal quarters is difficult to achieve. The purpose of this study was to assess the results of plating using locking screws and the feasibility of a minimally-invasive approach. All patients with tibial shaft fracture treated by means of locking plates from January 2004 to October 2006. Thirty-two fractures were treated in 32 patients with a mean age of 43.8 years. Internal fixation with a locking plate and screw construct, using a minimally-invasive or standard approach. Surgical approach, time to weight bearing, complications and their type, time to bone union, alignment in the frontal and sagittal planes on anteroposterior and lateral radiographs. The minimally-invasive approach was performed in 28 cases and immediate full weight bearing allowed in 25 cases. At a mean follow-up of 27 months, two patients had died and two patients were lost to follow-up. The mean time to bone union was 9.1 weeks. Four cases had a complicated course: one infection, one compartment syndrome, one hardware breakage and one pseudarthrosis. Six cases ended up with valgus malunion exceeding 5° in the frontal plane, already present at the time of surgery. Where a minimally-invasive approach can be performed, immediate pain-free weight bearing can be allowed without further displacement at follow-up. The observed rate of malunion underlines the need for adequate reduction and shows that the rationale for success does not solely depend on the plate anatomic design but also on the skills of the operating surgeon. Level I university regional hospital Cohort study. Copyright © 2012. Published by Elsevier Masson SAS.

  11. [Close reduction combined with minimally invasive percutaneous plate osteosynthesis for proximal and distal tibial fractures: a report of 56 patients].

    Science.gov (United States)

    Liu, Yin-Wen; Kuang, Yong; Gu, Xin-Feng; Zheng, Yu-Xin; Li, Zhi-Qiang; Wei, Xiao-En; Zhang, Ming-Cai; Zhan, Hong-Sheng; Shi, Yin-yu

    2013-03-01

    To evaluate the clinical effects of close reduction combined with minimally invasive percutanous plate osteosynthesis (MIPPO) for proximal and distal tibial fractures. From March 2007 to December 2010, 56 patients with proximal and distal tibial fractures were treated with close reduction combined with MIPPO technique. There were 39 males and 17 females,aged from 22 to 67 years with an average of 41.3 years. Left fracture was in 25 cases and right fracture was in 31 cases; proximal tibial fracture was in 15 cases and distal tibial fractures was in 41 cases; 34 cases caused by fall down and 22 cases caused by road accident. The mean time from injury to operation was 1.7 d. Clinical manifestation included pain, swelling of leg with limitation of activity. According to the standard of Johner-Wruhs, clinical effects were evaluated. The mean operative time was 46 min in 56 patients. All fractures obtained satisfactory reduction and the location of plate was good. Incisions healed with one-stage and no superficial or deep infection was found. All the patients were followed up from 8 to 23 months with an average of 14.2 months. Only one fracture complication with delayed union,and after auto grafting with ilium bone,the fracture got union. Other 55 cases obtained bone healing in 15 to 20 weeks after operation and no internal fixation failure was found. The time of walking was 4-6 months after operation,without limping at 7 months after operation. Both lower extremities were symmetrical and the function of knee and ankle got complete recovery. According to the criteria of Johner-Wruhs score,46 cases obtained excellent results,9 good and 2 fair. Treatment of proximal and distal tibial fractures with close reduction and MIPPO technique can not only preserve soft tissue,simplify operative procedure and decrease wound, but also can obtain rigid internal fixation and guarantee early function exercises of knee and ankle joints. The method has the advantages of less soft tissue

  12. [Comparison study on locking compress plate external fixator and standard external fixator for treatment of tibial open fractures].

    Science.gov (United States)

    Wu, Gang; Luo, Xiaozhong; Tan, Lun; Lin, Xu; Wu, Chao; Guo, Yong; Zhong, Zewei

    2013-11-01

    To compare the clinical results of locking compress plate (LCP) as an external fixator and standard external fixator for treatment of tibial open fractures. Between May 2009 and June 2012, 59 patients with tibial open fractures were treated with LCP as an external fixator in 36 patients (group A), and with standard external fixator in 23 patients (group B). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, location, and interval between injury and surgery between 2 groups (P > 0.05). The time of fracture healing and incision healing, the time of partial weight-bearing, the range of motion (ROM) of knee and ankle, and complications were compared between 2 groups. The incidence of pin-track infection in group A (0) was significantly lower than that in group B (21.7%) (P=0.007). No significant difference was found in the incidence of superficial infection and deep infection of incision, and the time of incision healing between 2 groups (P > 0.05). Deep vein thrombosis occurred in 5 cases of group A and 2 cases of group B, showing no significant difference (Chi(2)=0.036, P=0.085). All patients were followed up 15.2 months on average (range, 9-28 months) in group A, and 18.6 months on average (range, 9-47 months) in group B. The malunion rate and nonunion rate showed no significant difference between groups A and B (0 versus 13.0% and 0 versus 8.7%, P > 0.05); the delayed union rate of group A (2.8%) was significantly lower than that of group B (21.7%) (Chi(2)=5.573, P=0.018). Group A had shorter time of fracture healing, quicker partial weight-bearing, greater ROM of the knee and ankle than group B (P fracture, and has good patients' compliance, so it is helpful to do functional exercise, improve fracture healing and function recovery, and reduce the complication incidence.

  13. Impact of double-tiered subchondral support procedure with a polyaxial locking plate on the stability of distal radius fractures using fresh cadaveric forearms: Biomechanical and radiographic analyses.

    Science.gov (United States)

    Tsutsui, Sadaaki; Kawasaki, Keikichi; Yamakoshi, Ken-Ichi; Uchiyama, Eiichi; Aoki, Mitsuhiro; Inagaki, Katsunori

    2016-09-01

    The present study compared the changes in biomechanical and radiographic properties under cyclic axial loadings between the 'double-tiered subchondral support' (DSS) group (wherein two rows of screws were used) and the 'non-DSS' (NDSS) group (wherein only one row of distal screws was used) using cadaveric forearm models of radius fractures fixed with a polyaxial locking plate. Fifteen fresh cadaveric forearms were surgically operated to generate an Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 23-C2 fracture model with the fixation of polyaxial volar locking plates. The model specimens were randomized into two groups: DSS (n = 7) and NDSS (n = 8). Both the groups received 4 locking screws in the most distal row, as is usually applied, whereas the DSS group received 2 additional screws in the second row inserted at an inclination of about 15° to support the dorsal aspect of the dorsal subchondral bone. Cyclic axial compression test was performed (3000 cycles; 0-250 N; 60 mm/min) to measure absolute rigidity and displacement, after 1, 1000, 2000 and 3000 cycles, and values were normalized relative to cycle 1. These absolute and normalized values were compared between those two groups. Radiographic images were taken before and after the cyclic loading to measure changes in volar tilt (ΔVT) and radial inclination (ΔRI). The DSS group maintained significantly higher rigidity and lower displacement values than the NDSS group during the entire loading period. Radiographic analysis indicated that the ΔVT values of the DSS group were lower than those of the NDSS group. In contrast, the fixation design did not influence the impact of loading on the ΔRI values. Biomechanical and radiographic analyses demonstrated that two rows of distal locking screws in the DSS procedure conferred higher stability than one row of distal locking screws. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  14. A COMPARATIVE STUDY OF PROXIMAL FEMUR LOCKING COMPRESSION PLATE VERSUS PROXIMAL FEMORAL NAILING IN THE MANAGEMENT OF COMMINUTED TROCHANTERIC AND SUBTROCHANTERIC FRACTURE

    Directory of Open Access Journals (Sweden)

    Satish Koti

    2016-11-01

    Full Text Available BACKGROUND Fractures of proximal femur and hip are relatively common injuries in elderly individuals constituting 11.6% of total fractures. The latest implant for management of intertrochanteric fracture is Proximal Femoral Locking Compression Plate (PF-LCP. In this study, we compare the clinical outcome of fractures treated by proximal femoral nail with that of proximal femur locking compression plate. MATERIALS AND METHODS The present study consists of 24 elderly patients of peritrochanteric factures of femur satisfying the inclusion criteria who were treated with PF-LCP or PFN in Department of Orthopaedics, S.V.R.R.G.G.H, Tirupati, during a period between December 2013 to October 2015. RESULTS 24 cases were treated with PF-LCP or PFN in a randomised pattern who satisfied inclusion criteria. Intraoperative complication were found to be more with PF-LCP in contrast to PFN. Postoperative rehabilitation was easier with PFN though not statistically significant functional and anatomical outcomes were found to be better with PFN. CONCLUSION Both PFN and PF-LCP have good effectiveness in the treatment of intertrochanteric fractures with the lateral unsubstantial femoral wall in the elderly patients. Each has its own advantages and disadvantages. Further studies with large number of patients and long-term follow up is needed to determine the optimal implant for the internal fixation of comminuted pertrochanteric femoral fractures.

  15. Locking plate fixation provides superior fixation of humerus split type greater tuberosity fractures than tension bands and double row suture bridges.

    Science.gov (United States)

    Gaudelli, Cinzia; Ménard, Jérémie; Mutch, Jennifer; Laflamme, G-Yves; Petit, Yvan; Rouleau, Dominique M

    2014-11-01

    This paper aims to determine the strongest fixation method for split type greater tuberosity fractures of the proximal humerus by testing and comparing three fixation methods: a tension band with No. 2 wire suture, a double-row suture bridge with suture anchors, and a manually contoured calcaneal locking plate. Each method was tested on eight porcine humeri. A osteotomy of the greater tuberosity was performed 50° to the humeral shaft and then fixed according to one of three methods. The humeri were then placed in a testing apparatus and tension was applied along the supraspinatus tendon using a thermoelectric cooling clamp. The load required to produce 3mm and 5mm of displacement, as well as complete failure, was recorded using an axial load cell. The average load required to produce 3mm and 5mm of displacement was 658N and 1112N for the locking plate, 199N and 247N for the double row, and 75N and 105N for the tension band. The difference between the three groups was significant (Prow (456N) and tension band (279N) (Prow (71N/mm) and tension band (33N/mm) (Pbiomechanical fixation for split type greater tuberosity fractures. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Locking plate and fibular strut-graft augmentation in the reconstruction of unicameral bone cyst of proximal femur in the paediatric population.

    Science.gov (United States)

    Jamshidi, Khodamorad; Mirkazemi, Masoud; Izanloo, Azra; Mirzaei, Alireza

    2018-01-01

    Several therapeutic strategies have been used for managing unicameral bone cyst (UBC) of the proximal femur. However, there is insufficient evidence to support one treatment over another, and the optimal treatment is controversial. This study aims at describing our experience with surgical reconstruction of paediatric UBCs of the proximal femur using a proximal locking plate and fibular strut allograft. In total, 14 consecutive paediatric patients with Dormans types IB (four cases) and IIB (10 cases) UBC were assessed. Mean patient age was 8.6 ± 2.3 years, and mean follow-up period was 41.7 ± 29.8 months. Six patients (42.8%) were referred with a pathologic fracture. Clinical/radiological outcome and complication rates were evaluated at the final follow-up session. No cysts were Capanna's class III (recurrence) or IV (no response). Complete healing (Capanna's class I) was seen in ten cysts, while four other cysts healed with residual radiolucent areas (Capanna's class II). Mean healing period was 14.1 ± 5.1 (9-24 months). One patient had superficial infection, one heterotopic ossification, and one mild coxa vara, and mean Musculoskeletal Tumor Society (MSTS) score was 99.5%. According to our results, locking plate and fibular strut graft in Dormans classification types IB and IIB results in a favorable outcome in managing UBC of the proximal femur in the paediatric population.

  17. Societal costs in displaced transverse olecranon fractures: using decision analysis tools to find the most cost-effective strategy between tension band wiring and locked plating.

    Science.gov (United States)

    Francis, Tittu; Washington, Travis; Srivastava, Karan; Moutzouros, Vasilios; Makhni, Eric C; Hakeos, William

    2017-11-01

    Tension band wiring (TBW) and locked plating are common treatment options for Mayo IIA olecranon fractures. Clinical trials have shown excellent functional outcomes with both techniques. Although TBW implants are significantly less expensive than a locked olecranon plate, TBW often requires an additional operation for implant removal. To choose the most cost-effective treatment strategy, surgeons must understand how implant costs and return to the operating room influence the most cost-effective strategy. This cost-effective analysis study explored the optimal treatment strategies by using decision analysis tools. An expected-value decision tree was constructed to estimate costs based on the 2 implant choices. Values for critical variables, such as implant removal rate, were obtained from the literature. A Monte Carlo simulation consisting of 100,000 trials was used to incorporate variability in medical costs and implant removal rates. Sensitivity analysis and strategy tables were used to show how different variables influence the most cost-effective strategy. TBW was the most cost-effective strategy, with a cost savings of approximately $1300. TBW was also the dominant strategy by being the most cost-effective solution in 63% of the Monte Carlo trials. Sensitivity analysis identified implant costs for plate fixation and surgical costs for implant removal as the most sensitive parameters influencing the cost-effective strategy. Strategy tables showed the most cost-effective solution as 2 parameters vary simultaneously. TBW is the most cost-effective strategy in treating Mayo IIA olecranon fractures despite a higher rate of return to the operating room. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. Angular-stable locking plate fixation of tibial plateau fractures-clinical and radiological midterm results in 101 patients

    OpenAIRE

    Sven Mardian; Felix Landmann; Florian Wichlas; Norbert P Haas; Klaus-Dieter Schaser; Philipp Schwabe

    2015-01-01

    Background: Articular reconstruction and stable fixation of tibial plateau fractures and its various subtypes continue to represent a surgical challenge. Only few trials have studied results following angular stable plate fixation. The present study aimed to investigate the clinical, radiological, functional and quality of life results following tibial plateau fractures using angular stable plate fixation. Materials and Methods: 101 patients were retrospectively studied using functional (...

  19. Treatment of type 2 and 4 olecranon fractures with locking compression plate osteosynthesis in horses: a prospective study (2002-2008).

    Science.gov (United States)

    Jackson, M; Kummer, M; Auer, J; Hagen, R; Fuerst, A

    2011-01-01

    This prospective study describes a series of 18 olecranon fractures in 16 horses that were treated with locking compression plates (LCP). Twelve of the 18 fractures were simple (type 2), whereas six were comminuted (type 4). Six fractures were open and 12 were closed. Each horse underwent LCP osteosynthesis consisting of open reduction and application of one or two LCP. Complete fracture healing was achieved in 13 horses. Three horses had to be euthanatized: two because of severe infection and one because of a comminuted radial fracture 11 days after fixation of the olecranon fracture. Complications encountered after discharge of the horses from the Equine Hospital at the Vetsuisse Faculty (University of Zurich) included implant infection (n=2) and lameness (n=3), which were successfully treated with implant removal. Despite being easier to use, LCP osteosynthesis resulted in a clinical outcome similar to DCP osteosynthesis.

  20. Equine ulnar fracture repair with locking compression plates can be associated with inadvertent penetration of the lateral cortex of the radius.

    Science.gov (United States)

    Kuemmerle, Jan M; Kühn, Karolin; Bryner, Marco; Fürst, Anton E

    2013-10-01

    To evaluate if the use of locking head screws (LHS) in the distal holes of a locking compression plate (LCP) applied to the caudal aspect of the ulna to treat equine ulnar fractures is associated with a risk of injury to the lateral cortex of the radius. Controlled laboratory study. Cadaveric equine forelimbs (n = 8 pair). After transverse ulnar osteotomy, osteosynthesis was performed with a narrow 10-13 hole 4.5/5.0 LCP applied to the caudal aspect of each ulna. The distal 3 holes were filled with 4.5 mm cortex screws (CS) in 1 limb (group 1) and with 5.0 mm LHS contralaterally (group 2). CS were inserted in an angle deemed appropriate by the surgeon and LHS were inserted perpendicular to the plate. Implant position and injury to the lateral cortex of the radius were assessed by radiography, CT, and limb dissection. In group 1, injury of the lateral radius cortex did not occur. In group 2, 4 limbs and 6/24 LHS were associated with injury of the lateral radius cortex by penetration of a LHS. This difference was statistically significant. CS were inserted with a mean angle of 17.6° from the sagittal plane in a caudolateral-craniomedial direction. Use of LHS in the distal part of a LCP applied to the caudal aspect of the ulna is associated with a risk of inadvertent injury to the lateral cortex of the radius. © Copyright 2013 by The American College of Veterinary Surgeons.

  1. Aspects of internal fixation of fractures in porotic bone. Principles, technologies and procedures using locked plate screws.

    Science.gov (United States)

    Perren, S M; Linke, B; Schwieger, K; Wahl, D; Schneider, E

    2005-01-01

    Fractures of the bones of elderly people occur more often and have a more important effect because of a generally diminished ability to coordinate stance and walking. These fractures occur at a lower level of load because of lack of strength of the porotic bone. Prompt recovery of skeletal support function is essential to avoid respiratory and circulatory complications in the elderly. To prevent elderly people from the risks of being bedridden, demanding internal fixation of fractures is required. The weak porotic bone and the high level of uncontrolled loading after internal fixation pose complex problems. A combination of several technical elements of design, application and aftercare in internal fixation are proposed. Internal fixators with locked screws improve the biology and the mechanics of internal fixation. When such fixators are used as elevated splints they may stimulate early callus formation because of their flexibility, the limit of flexibility being set by the demands of resistance and function of the limb. Our own studies of triangulation of locked screws have demonstrated their beneficial effects and unexpected limitations.

  2. Patient-specific distal radius locking plate for fixation and accurate 3D positioning in corrective osteotomy.

    Science.gov (United States)

    Dobbe, J G G; Vroemen, J C; Strackee, S D; Streekstra, G J

    2014-11-01

    Preoperative three-dimensional planning methods have been described extensively. However, transferring the virtual plan to the patient is often challenging. In this report, we describe the management of a severely malunited distal radius fracture using a patient-specific plate for accurate spatial positioning and fixation. Twenty months postoperatively the patient shows almost painless reconstruction and a nearly normal range of motion.

  3. Drilling the near cortex with elongated figure-of-8 holes to reduce the stiffness of a locking compression plate construct.

    Science.gov (United States)

    Chen, Jerry Yongqiang; Zhou, Zhihong; Ang, Benjamin Fu Hong; Yew, Andy Khye Soon; Chou, Siaw Meng; Chia, Shi-Lu; Koh, Joyce Suang Bee; Howe, Tet Sen

    2015-12-01

    To compare the stiffness of locking compression plate (LCP) constructs with or without drilling the near cortex with elongated figure-of-8 holes. 24 synthetic bones were sawn to create a 10-mm gap and were fixed with a 9-hole 4.5-mm narrow LCP. In 12 bones, the near cortex of the adjacent holes to the LCP holes was drilled to create elongated figure-of-8 holes before screw insertion. The stiffness of LCP constructs under axial loading or 4-point bending was assessed by (1) dynamic quasi-physiological testing for fatigue strength, (2) quasi-static testing for stiffness, and (3) testing for absolute strength to failure. None of the 24 constructs had subcatastrophic or catastrophic failure after 10 000 cycles of fatigue loading (p=1.000). The axial stiffness reduced by 16% from 613±62 to 517±44 N/mm (p=0.012) in the case group, whereas the bending stiffness was 16±1 Nm2 in both groups (p=1.000). The maximum axial load to catastrophic failure was 1596±84 N for the control group and 1627±48 N for the case group (p=0.486), whereas the maximum bending moment to catastrophic failure was 79±12 and 80±10 Nm, respectively (p=0.919). Drilling the near cortex with elongated figure-of-8 holes reduces the axial stiffness of the LCP construct, without compromising its bending stiffness or strength.

  4. Assessment of Outcomes of Treatment of Fractures of Distal Femur with a Locking Plate Taking into Account Factors Influencing the Result.

    Science.gov (United States)

    Pakuła, Grzegorz; Kwiatkowski, Krzysztof; Kuczmera, Piotr; Fudalej, Piotr

    2015-10-01

    The aim of this paper is to evaluate the results of treatment of distal femoral fractures (DFF) fixed with locking plates and analysis of factors that influence the final outcome. The patients were treated at the Department of Traumatology and Orthopedics, Military Medical Institute in Warsaw, and the Department of Orthopedics and Traumatology, 4th Military Research Hospital in Wroclaw. We analysed 39 patients with 42 fractures of the distal femur. Treatment results were analysed using the KOOS and KSS scales. Factors influencing the outcome were also investigated. Statistical analysis was performed using STATISTICA v. 10. Mean KOOS scores indicate a predominance of poor outcomes, while mean KSS scores indicate good outcomes. Treatment outcomes were significantly influenced by pain and limited mobility. 1. Subjective evaluation of treatment of fractures of the distal femur using the KOOS scale per form edworse than a clinical evaluation using the KSS. 2. Post-operative management should emphasise pain relief and restoration of the performance of the treated lower limb to ensure good mobility without crutches. 3. Despite the use of modern operational methods of fracture fixation, treatment of distal femur fractures is still a challenge.

  5. A CLINICAL STUDY OF PROXIMAL FEMUR LOCKING COMPRESSION PLATE (LCP - PF IN THE MANAGEMENT OF COMMUNITED INTERTROCHANTERIC AND SUBTROCHANTERIC FRACTURES OF THE FEMUR

    Directory of Open Access Journals (Sweden)

    Hari Babu

    2015-10-01

    Full Text Available Fractures of proximal femur and hip are relatively common injuries in elderly individuals . The incidence of peritrochanteric and intertrochanteric fracture is also increasing among young population, who sustain high energy trauma Rigid Internal fixation and early mobilization has been the standard method of treatment. A combination of orthopaedic surgery and early postoperative physiotherapy and ambulation is the best approach. The overall goal in the treatment of hip fractures is to return the patient to pre - morbid level of function. AIMS & OBJECTIVE : To analyse the anatomical and f unctional outcome of the treatment with LCP - Proximal femur. METHODOLOGY : The present study consists of 12 adult patients of peritrochanteric factures of femur satisfying the inclusion criteria , treated with Proximal Femoral Locking Compression Plate at S. V. R. R . Govt . General Hospital, Tirupati during the period of nov 2013 to Oct 2015. INCLUSION CRITERIA : Age >18years , comminuted trochanteric and sub trochanteric fractures , Signed written informed consent . EXCLUSION CRITERIA: Inter trochanteric fractures involving piriformis fossa , Compound fractures . Pathological fractures . Any displacement of a femoral neck fracture . A ssociated malignancy. RESULTS : Average age incidence in the present study was 62.7 years. , Predominantly males (75% were affected. , Most cases occurred after a fall 10 (50% cases which was statistically significant , Right side involvement was more common. , Average post - operative stay was 13.5 days. , Out of the 12 cases, evaluated using Salvati - Wilson scoring : 3 cases (25% had good, 8 cases (66.67% fair, 1 case (8.33% had poor score , Average weight bearing time was14.5 weeks , Average union rate was 19.45 weeks.

  6. Biomechanics of far cortical locking.

    Science.gov (United States)

    Bottlang, Michael; Feist, Florian

    2011-02-01

    The development of far cortical locking (FCL) was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biologic fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have been shown to enhance fixation and healing of fractures: flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80% to 88% to actively promote callus proliferation similar to an external fixator. Load is evenly distributed between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by the S-shaped flexion of FCL screws promotes symmetric callus formation. In combination, these features of FCL constructs have been shown to induce more callus and to yield significantly stronger and more consistent healing compared with standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biologic healing response of external fixators.

  7. Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol.

    Science.gov (United States)

    Raduan Neto, Jorge; de Moraes, Vinicius Ynoe; Gomes Dos Santos, João B; Faloppa, Flávio; Belloti, João Carlos

    2014-03-05

    Various treatments are available for reducible unstable fractures of the distal radius, such as closed reduction combined with fixation by external fixator (EF), and rigid internal fixation using a locked volar plate (VP). Although there are studies comparing these methods, there is no conclusive evidence indicating which treatment is best. The hypothesis of this study is that surgical treatment with a VP is more effective than EF from the standpoint of functional outcome (patient-reported). The study is randomized clinical trial with parallel groups and a blinded evaluator and involves the surgical interventions EF and VP. Patients will be randomly assigned (assignment ratio 1:1) using sealed opaque envelopes. This trial will include consecutive adult patients with an acute (up to 15 days) displaced, unstable fracture of the distal end of the radius of type A2, A3, C1, C2 or C3 by the Arbeitsgemeinschaft für Osteosynthesefragen-Association for the Study of Internal Fixation classification and type II or type III by the IDEAL32 classification, without previous surgical treatments of the wrist. The surgical intervention assigned will be performed by three surgical specialists familiar with the techniques described. Evaluations will be performed at 2, and 8 weeks, 3, 6 and 12 months, with the primary outcomes being measured by the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire and measurement of pain (Visual Analog Pain Scale and digital algometer). Secondary outcomes will include radiographic parameters, objective functional evaluation (goniometry and dynamometry), and the rate of complications and method failure according to the intention-to-treat principle. Final postoperative evaluations (6 and 12 months) will be performed by independent blinded evaluators. For the Student's t-test, a difference of 10 points in the DASH score, with a 95% confidence interval, a statistical power of 80%, and 20% sampling error results in 36 patients per group

  8. Automatic locking radioisotope camera lock

    International Nuclear Information System (INIS)

    Rosauer, P.J.

    1978-01-01

    The lock of the present invention secures the isotope source in a stored shielded condition in the camera until a positive effort has been made to open the lock and take the source outside of the camera and prevents disconnection of the source pigtail unless the source is locked in a shielded condition in the camera. It also gives a visual indication of the locked or possible exposed condition of the isotope source and prevents the source pigtail from being completely pushed out of the camera, even when the lock is released. (author)

  9. Filling Open Screw Holes in the Area of Metaphyseal Comminution Does Not Affect Fatigue Life of the Synthes Variable Angle Distal Femoral Locking Plate in the AO/OTA 33-A3 Fracture Model.

    Science.gov (United States)

    Grau, Luis; Collon, Kevin; Alhandi, Ali; Kaimrajh, David; Varon, Maria; Latta, Loren; Vilella, Fernando

    2018-06-01

    The aim of this study is to evaluate the biomechanical effect of filling locking variable angle (VA) screw holes at the area of metaphyseal fracture comminution in a Sawbones® (Sawbones USA, Vashon, Washington) model (AO/OTA 33A-3 fracture) using a Synthes VA locking compression plate (LCP) (Depuy Synthes, Warsaw, Indiana). Seven Sawbones® femur models had a Synthes VA-LCP placed as indicated by the manufacturers technique. A 4cm osteotomy was then created to simulate an AO/OTA 33-A3 femoral fracture pattern with metaphyseal comminution. The control group consisted of four constructs in which the open screw holes at the area of comminution were left unfilled; the experimental group consisted of three constructs in which the VA screw holes were filled with locking screws. One of the control constructs was statically loaded to failure at a rate of 5mm/min. A value equal to 75% of the ultimate load to failure was used as the loading force for fatigue testing of 250,000 cycles at 3Hz. Cycles to failure was recorded for each construct and averages were compared between groups. The average number of cycles to failure in the control and experimental groups were 37524±8187 and 43304±23835, respectively (p=0.72). No significant difference was observed with respect to cycles to failure or mechanism of failure between groups. In all constructs in both the control and experimental groups, plate failure reproducibly occurred with cracks through the variable angle holes in the area of bridged comminution. The Synthes VA-LCP in a simulated AO/OTA 33-A3 comminuted metaphyseal femoral fracture fails in a reproducible manner at the area of comminution through the "honeycomb" VA screw holes. Filling open VA screw holes at the site of comminution with locking screws does not increase fatigue life of the Synthes VA-LCP in a simulated AO/OTA 33-A3 distal femoral fracture. Further studies are necessary to determine whether use of this particular plate is contraindicated when bridging

  10. Air lock

    International Nuclear Information System (INIS)

    Palkovich, P.; Gruber, J.; Madlener, W.

    1974-01-01

    The patent refers to an air lock system preferably for nuclear stations for the transport of heavy loads by means of a trolley on rails. For opening and closing of the air lock parts of the rails are removed, e.g. by a second rail system perpendicular to the main rails. (P.K.)

  11. [Long-term results of calcaneal fracture treatment by open reduction and internal fixation using a calcaneal locking compression plate from an extended lateral approach].

    Science.gov (United States)

    Zeman, P; Zeman, J; Matejka, J; Koudela, K

    2008-12-01

    To report on the surgical treatment of intra-articular calcaneal fractures by open reduction and internal fixation with a calcaneal locking compression plate (LCP) from an extended lateral approach, and to retrospectively analyze the mid-term results in a group of patients treated by this technique. In the period from August 2005 till March 2007, a total of 49 patients with 61 calcaneal fractures were treated. Of these, 11 (18 %) were treated conservatively. Reduction combined with Kirschner-wire fixation was used in four fractures (6.6 %). Open reduction with internal calcaneal LCP fixation (ORIF- calcaneal LCP) from an extended lateral approach was carried out to treat 46 fractures (75.4 %) in 38 patients. The group evaluated here comprised 29 patients with 33 calcaneal fractures treated by ORIF-calcaneal LCP at a follow-up longer than 6 months. The fractures were classified on the basis of computer tomography (CT) findings as Sanders types I to IV. The group had two woman (6.9 %) and 27 men (93.1 %) with an average age of 34.2 years (range, 19-55 years). In 11 fractures (33.3 %), the primary treatment included filling a central cancellous bone defect area. Calcium phosphate bone substitute material (resorbable ChronOS) was used in nine cases (27.3 %), a self-solidifying hydroxyapatite implant was injected in two (6.1 %) cases (X3 Wright and Norian SRS, respectively), and a bone allograft was implanted in one case (3 %). Indicated for surgery were patients with an intra-articular calcaneal fracture, Sanders type II or type III, with articular surface displacement by more than 1 mm. Contraindications included age over sixty years, poor cooperation, smoking habits, peripheral vascular disease or skin infection. Surgery was performed only after oedema had resolved. The aim of our treatment was to achieve anatomical reconstruction of all articular surfaces, to restore the height, length, width and axis of the heel bone, to carry out primary stable osteosynthesis, and

  12. Treatment of unstable sacral fractures with percutaneous reconstruction plate internal fixation Tratamento de fraturas sacrais instáveis com reconstrução percutânea com fixação de placa interna

    Directory of Open Access Journals (Sweden)

    Hong-Wei Chen

    2012-05-01

    Full Text Available PURPOSE: To study the effects of percutaneous reconstruction plate internal fixation in the treatment of unstable sacral fractures. METHODS: Percutaneous reconstruction plate internal fixation was applied on 21 cases of unstable sacral fracture (15 males and six females, at age range of 16-65 years, mean 38.3 years including four cases of Denis Zone I, 14 cases of Zone II and three cases of Zone III. In operation, an arc incision (about 3-5 cm long was made along the iliac crest on the outside border of posterior superior iliac spine (PSIS on both sides, and then the plate was transported from the wounded side to the opposite one through the subcutaneous tunnel. RESULTS: The mean incision length, operation time, intraoperative blood loss was 4.3cm, 45.2min, and 160.8ml respectively. All these patients were followed up for 12-33 months (average 16.3 months, which showed no incision infection, intraoperative neurovascular injury, internal fixation loose or breakage, disunion, or obvious lower limb length inequality. The function result was rated as excellent in six cases, good in 12 and fair in 3, with excellence rate of 85.7%, according to the Majeed scoring system. CONCLUSION: Percutaneous reconstruction plate internal fixation is an ideal surgical approach to unstable sacral fractures, as it is easy, safe, causing less trauma and fewer complications, and conducive to quicker recovery.OBJETIVO: Estudar os efeitos da reconstrução percutânea com fixação de placa interna no tratamento de fraturas sacrais instáveis. MÉTODOS: A reconstrução percutânea com fixação de placa interna foi aplicada em 21 casos de fratura sacral instável (15 homens e seis mulheres, com idade variando entre 16 e 65 anos, média de 38,3 anos incluindo quatro casos de Zona I de Denis, 14 casos de Zona II e três casos de Zona III. No ato operatório, uma incisão arqueada (cerca de 3 a 5cm de comprimento foi feita ao longo da crista ilíaca na borda externa da

  13. Features of Three- and Four-Part Proximal Humeral Fractures and Outcome of Internal Fixation Using the Philos® Locking Plate

    Directory of Open Access Journals (Sweden)

    Ali Sadighi

    2017-03-01

    Full Text Available Background: Proximal humeral fractures are among common types of fractures and remain a challenging issue for surgical management. This study aimed to assess the clinical outcomes and complication rates of three- vs. four-part proximal humeral fractures, treated with internal fixation using the Philos® plate. Material and Methods: In this cohort study, a total of 30 consecutive patients with three-part or four-part proximal humeral fractures based on the Neer classification were included. Surgical treatment was performed with open reduction and internal fixation using the Philos® plate. The constant score was evaluated 6 months later in follow-up. The P<0.05 was considered significant. Results: Four-part fractures were mainly caused by trauma from above, while insults of opposite direction were responsible for more than half of 3 part fractures (P=0.01. Open fractures were only observed in patients with a four-part fracture (P=0.018. No significant differences were noticed regarding gender, cause, and side of the fracture. The presence of other fractures, fracture of the implant, reduction loss, avascular necrosis (AVN of humerus head, rotator cuff injury, and revision surgery were significantly higher in patients with four-part fractures. The mean constant score was 81.40±11.61 and 65.09±16.09 for three-part and four-part fractures, respectively (P=0.006. Conclusion: Open reduction and internal fixation with Philos® plate yield acceptable results in both types of fractures, however, the prognosis of this intervention is poorer four-part fractures.

  14. Automatic locking orthotic knee device

    Science.gov (United States)

    Weddendorf, Bruce C. (Inventor)

    1993-01-01

    An articulated tang in clevis joint for incorporation in newly manufactured conventional strap-on orthotic knee devices or for replacing such joints in conventional strap-on orthotic knee devices is discussed. The instant tang in clevis joint allows the user the freedom to extend and bend the knee normally when no load (weight) is applied to the knee and to automatically lock the knee when the user transfers weight to the knee, thus preventing a damaged knee from bending uncontrollably when weight is applied to the knee. The tang in clevis joint of the present invention includes first and second clevis plates, a tang assembly and a spacer plate secured between the clevis plates. Each clevis plate includes a bevelled serrated upper section. A bevelled shoe is secured to the tank in close proximity to the bevelled serrated upper section of the clevis plates. A coiled spring mounted within an oblong bore of the tang normally urges the shoes secured to the tang out of engagement with the serrated upper section of each clevic plate to allow rotation of the tang relative to the clevis plate. When weight is applied to the joint, the load compresses the coiled spring, the serrations on each clevis plate dig into the bevelled shoes secured to the tang to prevent relative movement between the tang and clevis plates. A shoulder is provided on the tang and the spacer plate to prevent overextension of the joint.

  15. Study of transient flow in fuel element of tubular plates. Accident: Shaft locking of primary cooling pump without opening the emergency gate; Estudio del regimen transitorio en el elemento combustible de placas tubulares. Accidente: Agarrotamiento de la bomba. No se abre la compuerta

    Energy Technology Data Exchange (ETDEWEB)

    Aguilas, F; Moneva, M A; Garcia Ramirez, L; Lopez Jimenez, J; Diaz Diaz, J

    1971-07-01

    It is analysed the thermal distribution of a fuel element of tubular plates irradiated in the JEN-1 reactor in the case of shaft locking of the primary cooling pump without opening the emergency gate. The fuel element hottest channel is studied in the position of maximum neutronic flux for three reactor power levels: 3 Hw (maximum reactor power), 2 Mw and 1 Hw. (Author) 8 refs.

  16. Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience.

    Science.gov (United States)

    Yu, Ke-He; Hong, Jian-Jun; Guo, Xiao-Shan; Zhou, Dong-Sheng

    2015-09-22

    The objective of this study is to compare the biomechanical properties and clinical outcomes of Tile B1 type pubic symphysis diastasis (PSD) treated by percutaneous cannulated screw fixation (PCSF) and reconstruction plate screw fixation (RPSF). Finite element analysis (FEA) was used to compare the biomechanical properties between PCSF and RPSF. CT scan data of one PSD patient were used for three-dimensional reconstructions. After a validated pelvic finite element model was established, both PCSF and RPSF were simulated, and a vertical downward load of 600 N was loaded. The distance of pubic symphysis and stress were tested. Then, 51 Tile type B1 PSD patients (24 in the PCSF group; 27 in the RPSF group) were reviewed. Intra-operative blood loss, operative time, and the length of the skin scar were recorded. The distance of pubic symphysis was measured, and complications of infection, implant failure, and revision surgery were recorded. The Majeed scoring system was also evaluated. The maximum displacement of the pubic symphysis was 0.408 and 0.643 mm in the RPSF and PCSF models, respectively. The maximum stress of the plate in RPSF was 1846 MPa and that of the cannulated screw in PCSF was 30.92 MPa. All 51 patients received follow-up at least 18 months post-surgery (range 18-54 months). Intra-operative blood loss, operative time, and the length of the skin scar in the PCSF group were significantly different than those in the RPSF group. No significant differences were found in wound infection, implant failure, rate of revision surgery, distance of pubic symphysis, and Majeed score. PCSF can provide comparable biomechanical properties to RPSF in the treatment of Tile B1 type PSD. Meanwhile, PCSF and RPSF have similar clinical and radiographic outcomes. Furthermore, PCSF also has the advantages of being minimally invasive, has less blood loss, and has shorter operative time and skin scar.

  17. Percutaneous nephrostomy

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, In Hoon; Ryu, Kook Hyun; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun; Chung, Hyeon De [Chonnam National University College of Medicine, Chonju (Korea, Republic of)

    1990-12-15

    Percutaneous nephrostomy was performed in 82 patients under the fluoroscopic guidance for recent 3 years. The cause of hydronephrosis were as follows: unknown origin of stricture (N=37), stone (N=20), tumor (N=14), tuberculosis (N=8), postoperative ureteral injury (N=1), postoperative anastomotic stricture(N=1)and renal transplantation complication (N=1). Successful nephrostomy was achieved in 79 patients (96%). Causes if failure were minimal dilatation of pelvocaliceal system (N=2) and staghorn calculi (N=1). Follow up laboratory test shows high BUN and creatinine level returned to normal limit within 1 or 3 weeks in 73 patient. Major complication was not found, but temporary hematuria (N=4) or fever (N=1) was noted. In conclusion, percutaneous nephrostomy is the safe and effective method for the temporary and permanent relief of urinary obstruction and maintenance of ureteral patency.

  18. Percutaneous nephrostomy

    International Nuclear Information System (INIS)

    Ryu, In Hoon; Ryu, Kook Hyun; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun; Chung, Hyeon De

    1990-01-01

    Percutaneous nephrostomy was performed in 82 patients under the fluoroscopic guidance for recent 3 years. The cause of hydronephrosis were as follows: unknown origin of stricture (N=37), stone (N=20), tumor (N=14), tuberculosis (N=8), postoperative ureteral injury (N=1), postoperative anastomotic stricture(N=1)and renal transplantation complication (N=1). Successful nephrostomy was achieved in 79 patients (96%). Causes if failure were minimal dilatation of pelvocaliceal system (N=2) and staghorn calculi (N=1). Follow up laboratory test shows high BUN and creatinine level returned to normal limit within 1 or 3 weeks in 73 patient. Major complication was not found, but temporary hematuria (N=4) or fever (N=1) was noted. In conclusion, percutaneous nephrostomy is the safe and effective method for the temporary and permanent relief of urinary obstruction and maintenance of ureteral patency

  19. Locking of metacarpophalangeal joints in a patient with acromegaly

    Energy Technology Data Exchange (ETDEWEB)

    Tani, Y.; Tanaka, N.; Isoya, Eiji [Dept. of Orthopaedic Surgery, Soseikai General Hospital, Kyoto (Japan)

    1999-11-01

    A 39-year-old man with acromegaly exhibited locking of metacarpophalangeal (MCP) joints of both index fingers. Large osteophytes were found at the metacarpal heads by radiography and computerized tomography (CT). Magnetic resonance (MR) images revealed hypertrophy of volar plates. We suggest that these characteristic acromegalic features caused locking of MCP joints. Surgery was required on one of the joints to release the locking. (orig.)

  20. Locking of metacarpophalangeal joints in a patient with acromegaly

    International Nuclear Information System (INIS)

    Tani, Y.; Tanaka, N.; Isoya, Eiji

    1999-01-01

    A 39-year-old man with acromegaly exhibited locking of metacarpophalangeal (MCP) joints of both index fingers. Large osteophytes were found at the metacarpal heads by radiography and computerized tomography (CT). Magnetic resonance (MR) images revealed hypertrophy of volar plates. We suggest that these characteristic acromegalic features caused locking of MCP joints. Surgery was required on one of the joints to release the locking. (orig.)

  1. Percutaneous cholecystostomy

    International Nuclear Information System (INIS)

    Akhan, Okan; Akinci, Devrim; Oezmen, Mustafa N.

    2002-01-01

    Percutaneous cholecystostomy (PC), a technique that consists of percutaneous catheter placement in the gallbladder lumen under imaging guidance, has become an alternative to surgical cholecystostomy in recent years. Indications of PC include calculous or acalculous cholecystitis, cholangitis, biliary obstruction and opacification of biliary ducts. It also provides a potential route for stone dissolution therapy and stone extraction. Under aseptic conditions and ultrasound guidance, using local anesthesia, the procedure is carried out by using either modified Seldinger technique or trocar technique. Transhepatic or transperitoneal puncture can be performed as an access route. Several days after the procedure transcatheter cholangiography is performed to assess the patency of cystic duct, presence of gallstones and catheter position. The tract is considered mature in the absence of leakage to the peritoneal cavity, subhepatic, subcapsular, or subdiaphragmatic spaces. Response rates to PC in the literature are between the range of 56-100% as the variation of different patient population. Complications associated with PC usually occur immediately or within days and include haemorrhage, vagal reactions, sepsis, bile peritonitis, pneumothorax, perforation of the intestinal loop, secondary infection or colonisation of the gallbladder and catheter dislodgment. Late complications have been reported as catheter dislodgment and recurrent cholecystitis. PC under ultrasonographic guidance is a cost-effective, easy to perform and reliable procedure with low complication and high success rates for critically ill patients with acute cholecystitis. It is generally followed by elective cholecystectomy, if possible. However, it may be definitive treatment, especially in acalculous cholecystitis

  2. Percutaneous cholecystostomy

    Energy Technology Data Exchange (ETDEWEB)

    Akhan, Okan E-mail: akhano@tr.net; Akinci, Devrim; Oezmen, Mustafa N

    2002-09-01

    Percutaneous cholecystostomy (PC), a technique that consists of percutaneous catheter placement in the gallbladder lumen under imaging guidance, has become an alternative to surgical cholecystostomy in recent years. Indications of PC include calculous or acalculous cholecystitis, cholangitis, biliary obstruction and opacification of biliary ducts. It also provides a potential route for stone dissolution therapy and stone extraction. Under aseptic conditions and ultrasound guidance, using local anesthesia, the procedure is carried out by using either modified Seldinger technique or trocar technique. Transhepatic or transperitoneal puncture can be performed as an access route. Several days after the procedure transcatheter cholangiography is performed to assess the patency of cystic duct, presence of gallstones and catheter position. The tract is considered mature in the absence of leakage to the peritoneal cavity, subhepatic, subcapsular, or subdiaphragmatic spaces. Response rates to PC in the literature are between the range of 56-100% as the variation of different patient population. Complications associated with PC usually occur immediately or within days and include haemorrhage, vagal reactions, sepsis, bile peritonitis, pneumothorax, perforation of the intestinal loop, secondary infection or colonisation of the gallbladder and catheter dislodgment. Late complications have been reported as catheter dislodgment and recurrent cholecystitis. PC under ultrasonographic guidance is a cost-effective, easy to perform and reliable procedure with low complication and high success rates for critically ill patients with acute cholecystitis. It is generally followed by elective cholecystectomy, if possible. However, it may be definitive treatment, especially in acalculous cholecystitis.

  3. A comparison of anterior cervical discectomy and fusion (ACDF) using self-locking stand-alone polyetheretherketone (PEEK) cage with ACDF using cage and plate in the treatment of three-level cervical degenerative spondylopathy: a retrospective study with 2-year follow-up.

    Science.gov (United States)

    Chen, Yuqiao; Lü, Guohua; Wang, Bing; Li, Lei; Kuang, Lei

    2016-07-01

    To evaluate the clinical efficacy and radiological outcomes of anterior cervical discectomy and fusion (ACDF) using self-locking polyetheretherketone (PEEK) cages for treatment of three-level cervical degenerative spondylopathy. Twenty-eight patients underwent three-level ACDF using self-locking stand-alone PEEK cages (group A), and 26 patients underwent three-level ACDF using cages and plate fixation (group B) were reviewed retrospectively. Clinical efficacy was evaluated by pre- and post-operative Japanese Orthopedic Association (JOA) scores and Neck Disability Index (NDI). The operation time, blood loss, surgical results according to Odom's criteria and post-operative dysphagia status were also recorded. Radiological outcomes including fusion, cervical Cobb's lordosis, fused segment angle, disc height, and cage subsidence were assessed. Clinical outcome measures such as dysphagia and fusion rate and the results of surgery evaluated according to Odom's criteria were not statistically significant (P > 0.05) between groups. The operation time was shorter and blood loss was less in group A (P  0.05). Post-operative cage subsidence, the loss of disc height, cervical lordosis and the fused segment angle were relatively higher in group A than group B (P < 0.05). ACDF using self-locking stand-alone cages showed similar clinical results as compared to ACDF using cages and plate fixation for the treatment of three-level cervical degenerative spondylopathy. However, potential long-term problems such as cage subsidence, loss of cervical lordosis and fused segment angle post-operatively were shown to be associated with patients who underwent ACDF using self-locking stand-alone cages.

  4. Rotationally Stable Screw-Anchor With Locked Trochanteric Stabilizing Plate Versus Proximal Femoral Nail Antirotation in the Treatment of AO/OTA 31A2.2 Fracture: A Biomechanical Evaluation.

    Science.gov (United States)

    Knobe, Matthias; Nagel, Philipp; Maier, Klaus-Jürgen; Gradl, Gertraud; Buecking, Benjamin; Sönmez, Tolga T; Modabber, Ali; Prescher, Andreas; Pape, Hans-Christoph

    2016-01-01

    Third-generation cephalomedullary nails currently represent the gold standard in the treatment of unstable trochanteric femur fractures. Recently, an extramedullary rotationally stable screw-anchor system (RoSA) has been developed. It was designed to combine the benefits of screw and blade and to improve stability using a locked trochanteric stabilizing plate (TSP). The purpose of this study was to compare the biomechanical behavior of RoSA/TSP and the proximal femoral nail antirotation (PFNA). Standardized AO/OTA 31A2.2 fractures were induced by an oscillating saw in 10 paired human specimens (n = 20; mean age = 85 years; range: 71-96 years). The fractures were stabilized by either the RoSA/TSP (Koenigsee Implants, Allendorf, Germany) or the PFNA (DePuy Synthes, Zuchwil, Switzerland). Femurs were positioned in 25 degrees of adduction and 10 degrees of posterior flexion and were cyclically loaded with axial sinusoidal pattern at 0.5 Hz, starting at 300 N, with stepwise increase by 300 N every 500 cycles until bone-implant failure occurred. After every load step, the samples were measured visually and radiographically. Femoral head migration was assessed. The stiffness at the load up to the clinically relevant load step of 1800 N (639 ± 378 N/mm (RoSA/TSP) vs. 673 ± 227 N/mm (PFNA); P = 0.542) was comparable, as was the failure load (3000 ± 787 N vs. 3780 ± 874 N; P = 0.059). Up to 1800 N, no femoral head rotation, head migration, or femoral neck shortening were observed either for RoSA/TSP or PFNA. Whereas failure of the PFNA subsumed fractures of the greater trochanter and the lateral wall, a posterior femoral neck fracture with a significantly increased femoral neck shortening (1.7 mm vs. 0 mm; P = 0.012) was the cause of failure with RoSA/TSP. This specific kind of failure was induced by a femoral neck weakening caused by the posterior TSP stabilizing screw. There was no significant difference in biomechanical properties between the RoSA/TSP and the PFNA for

  5. Percutaneous Tracheostomy

    Science.gov (United States)

    Mehta, Chitra; Mehta, Yatin

    2017-01-01

    Percutaneous dilatational tracheostomy (PDT) is a commonly performed procedure in critically sick patients. It can be safely performed bedside by intensivists. This has resulted in decline in the use of surgical tracheostomy in intensive care unit (ICU) except in few selected cases. Most common indication of tracheostomy in ICU is need for prolonged ventilation. About 10% of patients requiring at least 3 days of mechanical ventilator support get tracheostomised during ICU stay. The ideal timing of PDT remains undecided at present. Contraindications and complications become fewer with increase in experience. Various methods of performing PDT have been discovered in last two decades. Preoperative work up, patient selection and post tracheostomy care form key components of a successful PDT. Bronchoscopy and ultrasound have been found to be useful procedural adjuncts, especially in presence of unfavorable anatomy. This article gives a brief overview about the use of PDT in ICU. PMID:28074819

  6. Percutaneous gastroenterostomy

    Energy Technology Data Exchange (ETDEWEB)

    Wittich, G.R.; Van Sonnenberg, E.; Casola, G.; Jantsch, H.; Walter, R.; Lechner, G.

    1987-05-01

    Percutaneous gastrostomies or gastroenterostomies serve for temporary or permanent enteric feeding in patients with obstruction or functional derangement of the esophagus or hypopharynx. In addition, this radiological procedure may be indicated for small bowel decompression. The authors present their experience in 71 patients. Insufflation of air through a nasogastric tube or catheter is the preferred method for gastric distension. The inferior margin of the left lobe of the liver and the transverse colon are localized sonographically and fluoroscopically prior to puncture. Either Seldinger or Trocartechniques have proven effective in establishing access to the stomach. The feeding tube is advanced into the proximal jejunum to reduce the likelyhood of gastroesophageal reflux and possible aspiration. Complications were encountered in four patients and included catheter dislocation in three and respiratory distress in one patient.

  7. Percutaneous angioscopy

    International Nuclear Information System (INIS)

    Beck, A.

    1987-01-01

    In dogs and 11 patients a new endoscopic method for arteries has been developed. The approach is transfemoral, and endoscopy is combined with angiography, percutaneous transluminal angioplasty (PTA), and local lysis. An ultrathin endoscope with a diameter of 2.4 mm is used, which also provides a working channel with a diameter of 0.4 mm. Guide wires, contrast media, and drugs for local lysis can be inserted through this channel. Under fluoroscopic control, the endoscope is placed in the region of interest, followed by a special method for decreasing blood flow. Endoscopy is documented by video or by a high-speed camera. No complications have occurred. In all patients, it was possible to demonstrate the results of dilatation, recanalization, or local lysis before and after the interventional procedure. (orig.) [de

  8. [Percutaneous tracheotomy].

    Science.gov (United States)

    Paleczny, J; Maciejewski, D; Łoniewska-Paleczny, E; Sawczuk, M; Kaczur, A

    2000-01-01

    The purpose of this study was to compare on the basis of up to date papers currently applied methods of the percutaneous tracheostomy (PT). There are four main PT methods by: Ciaglia, Schachner, Griggs and Fantoni. In these methods a wire is introduced into the trachea serving as a guide for special forceps or series of dilatators of increasing diameter to dilate the wall and allow cannulation of the trachea. In the literature authors found a low incidence of complications after PT. Acute complications were documented in 6-18% and late complications in 1-3% of the patients. Follow-up showed no late obstructive complications at the level of stomia and very low (0.3-0.36%) mortality risk. Translaryngeal tracheostomy (TLT) by Fantoni ensures minimal risk of complications and tissue trauma. In the TLT method through a needle inserted in to the trachea a guide wire is retrogradely pushed out of the mouth and attached to special flexible tracheostomy tube by flexible plastic cone with pointed metal tip. This device is then pulled back through larynx and outwards across the trachea and neck wall by traction on the wire. TLT can also be used in infants and children and in difficult patients in whom other techniques are riskier Review of the literature suggests that the PT can be safe and also cost-effective for properly selected patients in intensive care and other hospital units.

  9. PERCUTANEOUS ELECTROHEMOSTASIS AFTER PERCUTANEOUS NEPHROLITHOTOMY

    Directory of Open Access Journals (Sweden)

    R. N. Trushkin

    2017-01-01

    Full Text Available The article describes the clinical case in a patient with bilateral nephrolithiasis, chronic kidney disease of the 4th stage, after which bleeding from the left kidney developed after simultaneous bilateral percutaneous nephrolithotomy (PNL, leading to severe hemic hypoxia. Conservative therapy, blood transfusion did not lead to a persistent effect, the bleeding continued to recur. Given the presence of chronic renal failure (CRF from the embolization of the branches of the renal artery, it was decided to abstain, given the extremely high risk of aggravation of nephropathy after the administration of the contrast drug. Left-sided nephrectomy would inevitably lead to the development of terminal chronic renal failure. Patients performed an electrocoagulation of the fistula wall with a Karl Storz 26C resectoscope in 60W mode. The bleeding was completely stopped. The patient is discharged from the hospital in a satisfactory condition. At the time of discharge in the conduct of replacement renal therapy did not need. When analyzing publications in The Cochrane Library, PubMed, Medline and Web of Science, we did not find a description of such a method of hemostasis.

  10. A STUDY ON PROXIMAL HUMERAL FRACTURES STABILISED WITH PHILOS PLATE

    Directory of Open Access Journals (Sweden)

    Praveen Sivakumar K

    2017-02-01

    Full Text Available BACKGROUND Techniques for treating complex proximal humeral fractures vary and include fixations using tension bands, percutaneous pins, bone suture, T-plates, intramedullary nails, double tubular plates, hemiarthroplasty, plant tan humerus fixator plates, Polaris nails and blade plates. Complications of these techniques include cutout or back out of the screws and plates, avascular necrosis, nonunion, malunion, nail migration, rotator cuff impairment and impingement syndromes. Insufficient anchorage from conventional implants may lead to early loosening and failure, especially in osteoporotic bones. In general, nonoperative treatment of displaced three and four-part fractures of the proximal humerus leads to poor outcome due to intraarticular nature of injury and inherent instability of the fragments. Comminuted fractures of the proximal humerus are at risk of fixation failure, screw loosening and fracture displacement. Open reduction and internal fixation with conventional plate and screws has been associated with unacceptably high incidence of screw pull out. PHILOS (the proximal humeral internal locking system plate is an internal fixation system that enables angled stabilisation with multiple interlocking screws for fractures of the proximal humerus. MATERIALS AND METHODS 30 patients with proximal humerus fractures who were admitted in the Department of Orthopaedics, Government General Hospital, Kakinada, during the period November 2014 - November 2016 were taken up for study according to inclusion criteria. All patients were treated with PHILOS plate. These proximal humerus fractures were classified according to Neer’s classification. Patients were followed up at 6 weeks, 12 weeks and 6 months’ interval. Functional outcomes for pain, range of motion and muscle power and function were assessed using the Constant-Murley scoring system. Collected data analysed with independent t-test and ANNOVA test. RESULTS The outcome of the study was 1

  11. Protective air lock

    International Nuclear Information System (INIS)

    Evans, H.W.

    1976-01-01

    A device suitable for preventing escape and subsequent circulation of toxic gases is described. An enclosure is sealed by a surrounding air lock, and an automatic mechanism partially evacuates the enclosure and air lock. The enclosure ventilating mechanism can be disconnected so that a relatively undisturbed atmosphere is created in the enclosure

  12. Bicycle Parking and Locking

    DEFF Research Database (Denmark)

    Larsen, Jonas

    2017-01-01

    . This article contributes with new insights into parking and locking - ‘moorings’ - to cycling literature. It presents an ethnography of ‘design moorings’ and practices associated with parking and locking bikes. The main case study is the very pro-cycling city of Copenhagen. Yet to explore what is unique about...

  13. Reusable locking tube insertion and removal fixture and method in a reconstitutable fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Ferlan, S.J.

    1987-01-01

    This patent describes a locking tube insertion and removal fixture for use with a reconstitutable fuel assembly. The process includes a top nozzle with an adapter plate having at least one passageway, at least one guide thimble with an upper end portion, and an attaching structure having a hollow locking tube insertable and removable into and from a locking position in the upper end portion of the guide thimble for releasably locking the upper end portion of the guide thimble within the passageway of the top nozzle and adapter plate

  14. Percutaneous Ureteral stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yup; Sung, Dong Wook; Choi, Woo Suk; Lee, Dong Ho; Ko, Young Tae; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1990-10-15

    Percutaneous ureteral stent insertion is a treatment of permanent or temporary urinary diversion to maintain continuity and function of the obstructed and injured ureter. We performed 31 cases of percutaneous double pig tall ureteral stent insertion in 21 patients, included 13 patients with malignant ureteral obstruction and eight patients with injured ureter as well as benign inflammatory stricture. Satisfactory resulted was obtained in all patients but one, who need percutaneous nephrostomy on week later for urinary diversion. No significant complication was encountered. The authors concluded that percutaneous ureteral stent insertion, an interventional procedure alternative to urologic retrograde method, is an effective method for urinary diversion.

  15. ''Old'' locked inflation

    International Nuclear Information System (INIS)

    Liu, Yang; Piao, Yun-Song; Si, Zong-Guo

    2009-01-01

    In this paper, we revisit the idea of locked inflation, which does not require a potential satisfying the normal slow-roll condition, but suffers from the problems associated with ''saddle inflation''. We propose a scenario based on locked inflation, however, with an alternative evolution mechanism of the ''waterfall field'' φ. Instead of rolling down along the potential, the φ field will tunnel to end the inflation stage like in old inflation, by which the saddle inflation could be avoided. Further, we study a cascade of old locked inflation, which can be motivated by the string landscape. Our model is based on the consideration of making locked inflation feasible so as to give a working model without slow roll; It also can be seen as an effort to embed the old inflation in string landscape

  16. Quantum noise locking

    International Nuclear Information System (INIS)

    McKenzie, Kirk; Mikhailov, Eugeniy E; Goda, Keisuke; Lam, Ping Koy; Grosse, Nicolai; Gray, Malcolm B; Mavalvala, Nergis; McClelland, David E

    2005-01-01

    Quantum optical states which have no coherent amplitude, such as squeezed vacuum states, cannot rely on standard readout techniques to generate error signals for control of the quadrature phase. Here we investigate the use of asymmetry in the quadrature variances to obtain a phase-sensitive readout and to lock the phase of a squeezed vacuum state, a technique which we call noise locking (NL). We carry out a theoretical derivation of the NL error signal and the associated stability of the squeezed and anti-squeezed lock points. Experimental data for the NL technique both in the presence and absence of coherent fields are shown, including a comparison with coherent locking techniques. Finally, we use NL to enable a stable readout of the squeezed vacuum state on a homodyne detector

  17. LOCKS AND KEYS SERVICE

    CERN Multimedia

    Locks and Keys Service

    2002-01-01

    The Locks and Keys service (ST/FM) will move from building 55 to building 570 from the 2nd August to the 9th August 2002 included. During this period the service will be closed. Only in case of extreme urgency please call the 164550. Starting from Monday, 12th August, the Locks and Keys Service will continue to follow the activities related to office keys (keys and locks) and will provide the keys for furniture. The service is open from 8h30 to 12h00 and from 13h00 to 17h30. We remind you that your divisional correspondents can help you in the execution of the procedures. We thank you for your comprehension and we remain at your service to help you in solving all the matters related to keys for offices and furniture. Locks and Keys Service - ST Division - FM Group

  18. Locke and botany.

    Science.gov (United States)

    Anstey, Peter R; Harris, Stephen A

    2006-06-01

    This paper argues that the English philosopher John Locke, who has normally been thought to have had only an amateurish interest in botany, was far more involved in the botanical science of his day than has previously been known. Through the presentation of new evidence deriving from Locke's own herbarium, his manuscript notes, journal and correspondence, it is established that Locke made a modest contribution to early modern botany. It is shown that Locke had close and ongoing relations with the Bobarts, keepers of the Oxford Botanic Garden, and that Locke distributed seeds and plant parts to other botanists, seeds of which the progeny almost certainly ended up in the most important herbaria of the period. Furthermore, it is claimed that the depth of Locke's interest in and practice of botany has a direct bearing on our understanding of his views on the correct method of natural philosophy and on the interpretation of his well known discussion of the nature of species in Book III of his Essay concerning human understanding.

  19. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.

    Science.gov (United States)

    Paulsson, Johnny; Stig, Josefine Corin; Olsson, Ola

    2017-08-24

    In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the respective treatment protocol, whereas one treatment protocol (Medoff sliding plate/dynamic hip screw) uses biaxial Medoff sliding plate for unstable pertrochanteric fractures and uniaxial Medoff sliding plate for subtrochanteric fractures, the second (intramedullary nail/dynamic hip screw) uses intramedullary nail for subtrochanteric fractures and for pertrochanteric fractures with intertrochanteric comminution or subtrochanteric extension. All orthopedic surgeries are registered in a regional database. All consecutive trochanteric fracture operations during 2011-2012 (n = 856) and subsequent technical reoperations (n = 40) were derived from the database. Reoperations were analysed and classified into the categories adjustment (percutaneous removal of the locking screw of the Medoff sliding plate or the intramedullary nail, followed by fracture healing) or minor, intermediate (reosteosynthesis) or major (hip joint replacement, Girdlestone or persistent nonunion) technical complications. The relative risk of intermediate or major technical complications was 4.2 (1.2-14) times higher in unstable pertrochanteric fractures and 4.6 (1.1-19) times higher in subtrochanteric fractures with treatment protocol: intramedullary nail/dynamic hip screw, compared to treatment protocol: Medoff sliding plate/dynamic hip screw. Overall rates of intermediate and major technical complications in unstable pertrochanteric and subtrochanteric fractures were with biaxial Medoff sliding plate 0.68%, with uniaxial Medoff sliding plate 1.4%, with dynamic hip screw 3.4% and with intramedullary nail 7.2%. The

  20. Pressure locking test results

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.{close_quotes} Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; the authors will publish the results of their thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions.

  1. Pressure locking test results

    International Nuclear Information System (INIS)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D.

    1996-01-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, open-quotes Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.close quotes Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; we will publish the results of our thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions

  2. Percutaneous transhepatic biliary drainage

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Hong, Seong Mo; Han, Man Chung

    1982-01-01

    Percutaneous transhepatic biliary drainage was successfully made 20 times on 17 patients of obstructive jaundice for recent 1 year since June 1981 at Department of Radiology in Seoul National University Hospital. The causes of obstructive jaundice was CBD Ca in 13 cases, metastasis in 2 cases, pancreatic cancer in 1 case and CBD stone in 1 case. Percutaneous transhepatic biliary drainage is a relatively ease, safe and effective method which can be done after PTC by radiologist. It is expected that percutaneous transhepatic biliary drainage should be done as an essential procedure for transient permanent palliation of obstructive jaundice

  3. Positioning and locking apparatus

    Science.gov (United States)

    Hayward, M.L.; Harper, W.H.

    1985-06-19

    A positioning and locking apparatus including a fixture having a rotatable torque ring provided with a plurality of cam segments for automatically guiding a container into a desired location within the fixture. Rotation of the ring turns the container into a final position in pressure sealing relation against a hatch member.

  4. Locked nucleic acid

    DEFF Research Database (Denmark)

    Jepsen, Jan Stenvang; Sørensen, Mads D; Wengel, Jesper

    2004-01-01

    Locked nucleic acid (LNA) is a class of nucleic acid analogs possessing very high affinity and excellent specificity toward complementary DNA and RNA, and LNA oligonucleotides have been applied as antisense molecules both in vitro and in vivo. In this review, we briefly describe the basic...

  5. Roller Locking Brake

    Science.gov (United States)

    Vranish, John M.

    1993-01-01

    Roller locking brake is normally braking rotary mechanism allowing free rotation when electromagnet in mechanism energized. Well suited to robots and other machinery which automatic braking upon removal of electrical power required. More compact and reliable. Requires little electrical power to maintain free rotation and exhibits minimal buildup of heat.

  6. Locks and Keys Service

    CERN Multimedia

    Claude Ducastel

    The GS-LS-SEM section is pleased to inform you that as from Monday 30 November 2009, the opening hours of the Locks and Keys service will be the following: 08h30 - 12h30 / 13h30 - 16:30, Mondays to Fridays. GS-SEM-LS 73333

  7. Less invasive plate osteosynthesis in humeral shaft fractures.

    Science.gov (United States)

    Apivatthakakul, Theerachai; Phornphutkul, Chanakarn; Laohapoonrungsee, Anupong; Sirirungruangsarn, Yuddhasert

    2009-12-01

    Stable internal fixation of the humeral shaft by less invasive percutaneous plate insertion using two separate (proximal and distal) incisions, indirect reduction by closed manipulation and fixation to preserve the soft tissue and blood supply at the fracture zone. Early mobilization of the shoulder and elbow to ensure a good functional outcome. Humeral shaft fractures (classified according to AO classification as: 12-A, B, C). Humeral shaft fractures extending to the proximal or distal shaft, small or deformed medullary canal or open growth plate. Humeral shaft fractures with primary radial nerve palsy. Proximal humeral shaft fractures extending to the humeral head. Distal humeral fractures extending to the elbow joint. Two incisions proximal and distal to the fracture zone are used. A 3-cm proximal incision lies between the lateral border of the proximal part of the biceps and the medial border of the deltoid. Distally, a 3-cm incision is made along the lateral border of the biceps. The interval between biceps and brachialis is identified. The biceps is retracted medially to expose the musculocutaneous nerve. The brachialis muscle has dual innervation, the medial half being innervated by the musculocutaneous nerve and the lateral half by the radial nerve. The brachialis is split longitudinally at its midline. The musculocutaneous nerve is retracted along with the medial half of the brachialis, while the lateral half of the brachialis serves as a cushion to protect the radial nerve. A deep subbrachial tunnel is created from the distal to the proximal incision. The selected plate is tied with a suture to a hole at the tip of the tunneling instrument for pulling the plate back along the prepared track. The plate is aligned in the correct position on the anterior surface of the humerus. Traction is applied and the fracture reduced to restore alignment by image intensifier, followed by plate fixation with at least two bicortical locking screws or three bicortical

  8. Innovation and Lock-in

    DEFF Research Database (Denmark)

    Cantner, Uwe; Vannuccini, Simone

    2016-01-01

    This study focuses on a well-known but yet elusive concept: (technological) lock-in. We summarize what is known about the nature of lock-in and offer a critical view on history-dependent processes based on recent contributions to the literature. We discuss if lock-ins are really inescapable......, especially when innovation is concerned. Also, we address the question if lock-in is a well-defined concept at all. To offer a fresh view on lock-in and to tackle the issues just raised, we employ the replicator dynamics model. By making a parallel between monopolization in the replicator dynamics...... and the occurrence of lock-ins, we show that the convergence of a system to a given outcome can be reversed, under certain conditions. We highlight the need for a more precise demarcation of the conceptual boundaries of lock-in and path dependence, both from the formal and the empirical side, and suggest...

  9. Percutaneous intervention in obstructive

    International Nuclear Information System (INIS)

    Souftas, V.

    2012-01-01

    Percutaneous intervention procedures in obstructive uropathy include percutaneous nephrostomy tube placements, nephroureteral stents, percutaneous nephrostomy combined with ureteral embolization, percutaneous management of stone disease, suprapubic tube placements into the bladder, and perinephric/retroperitoneal urinomas/abscesses drainages. Percutaneous nephrostomy is performed to relieve urinary obstruction or divert the urinary stream away from the ureter or bladder. Patients are given preprocedure antibiotics. Percutaneous nephrostomies can be emergent cases because of risk of pyuria and sepsis from a stagnant urine collection. The procedure is performed using both ultrasound and fluoroscopy (or fluoroscopy alone using anatomic landmarks, or an internal radiopaque calculus, or delayed phase excretion of the contrast into the renal collecting system) under local anesthesia or conscious sedation. Ureteral stents are placed to bypass an obstructing stone or to stent across of an area of stricture or ureteral laceration. Stents may be placed by the urologist via a transurethral approach or by the interventional radiologist via a percutaneous approach. The decision as to method of stent placement is based upon the location and accessibility of the ureteral pathology. Ureteral embolization is performed in patients with unresectable tumors of the pelvis with long-standing nephrostomy tubes and distal urine leaks refractory to other treatments. Coils, gelfoam and liquid embolic materials can be used. Ureteral embolization for ureteral fistulas and incontinence is technically successful in 100% of the patients. Complications include bleeding, infection, ureteral or renal injury, and deployment (or movement) of the coils within the renal pelvis. Percutaneous management of stone disease, including renal, ureteral, and bladder stones requires close cooperation between the urologist and interventional radiologist, because of availability of sonographic lithotripsy

  10. Percutaneous transhepatic sphincterotomy

    International Nuclear Information System (INIS)

    Gandin, G.; Zanon, E.; Righi, D.; Fonio, P.; Ferrari, A.; Recchia, S.

    1990-01-01

    The authors describe the techique employed for percutaneous trans-hepatic sphincterotomy as performed on 3 patients with common bile duct (CBD) stones. In all patients, previous endoscopic attempt had failed for anatomical reasons (Billroth II gastric resection or partial gastric resection with brown anastomosis), and the ampulla could not be correctly incannulated with the sphincterotome. In all aptients endoscopy was useful to check the position of the diethermic loop inserted percutaneously. Conplete and immediate success was obtained in all 3 cases. No major complications occurred during transhepatic treatment. To date, 1 recurrence has been observed, and the patient has been retreated with bilioplasty. All patients were followed after 5-6 months with US, plain X-rays of the abdomen and blood tests (γGt, alkaline phosphatase, and bilirubinemia). The authors suggest that percutaneous transhepatic sphincterotomy be employed electively in patients with biliary tree diseases in case the endoscopic approach failes

  11. Data port security lock

    Science.gov (United States)

    Quinby, Joseph D [Albuquerque, NM; Hall, Clarence S [Albuquerque, NM

    2008-06-24

    In a security apparatus for securing an electrical connector, a plug may be fitted for insertion into a connector receptacle compliant with a connector standard. The plug has at least one aperture adapted to engage at least one latch in the connector receptacle. An engagement member is adapted to partially extend through at least one aperture and lock to at least one structure within the connector receptacle.

  12. Avoiding lock-in

    DEFF Research Database (Denmark)

    Henriksen, Ingrid

    1999-01-01

    The paper investigates the initial phase of the cooperative organisation of agricultural processing firms in Denmark. It argues that the variations observed can be explained within the framework of the theory of industrial organisation. The focus is on the success of cooperative creameries. In 19...... of gathering information and of preserving and transporting a perishable product, were ideally suited to overcome the problems of potential lock-in and of asymmetric information...

  13. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.

    Science.gov (United States)

    Kandemir, Utku; Augat, Peter; Konowalczyk, Stefanie; Wipf, Felix; von Oldenburg, Geert; Schmidt, Ulf

    2017-08-01

    To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Using the

  14. Reusable locking tube in a reconstitutable fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Ferlan, S.J.

    1987-01-01

    This patent describes a reconstitutable fuel assembly including a top nozzle with an adapter plate having an interior wall forming at least one passageway, at least one guide thimble with an upper end portion, and an attaching structure having an outer socket formed by a circumferential groove defined in the adapter plate passageway wall and opening into the passageway and an inner socket formed by a circumferential bulge and at least one longitudinal slot defined in the upper end portion of the guide thimble. The circumferential bulge is capable of seating within the circumferential groove, an improved reusable tube for releasably locking the inner socket of the guide thimble upper end portion in locking engagement within the outer socket of the adapter plate passageway when the circumferential bulge is seated within the circumferential groove. The reusable tube comprises: (a) an elongated hollow tubular body capable of insertion within the adapter plate passageway and guide thimble upper end portion to a locking position therein such that the circumferential bulge of the inner socket is maintained seated in the locking engagement with the circumferential groove of the outer socket; and (b) at least a pair of dimples performed on the exterior of the tubular body prior to insertion of the body in the guide thimble upper end portion and to the locking position, the dimples being performed and configured to increase the thickness of the tubular body in relation to the remainder of the tubular body. The dimples are substantially resisting resilient yielding in relation to the remainder of the tubular body

  15. Cold plate

    Energy Technology Data Exchange (ETDEWEB)

    Marroquin, Christopher M.; O' Connell, Kevin M.; Schultz, Mark D.; Tian, Shurong

    2018-02-13

    A cold plate, an electronic assembly including a cold plate, and a method for forming a cold plate are provided. The cold plate includes an interface plate and an opposing plate that form a plenum. The cold plate includes a plurality of active areas arranged for alignment over respective heat generating portions of an electronic assembly, and non-active areas between the active areas. A cooling fluid flows through the plenum. The plenum, at the non-active areas, has a reduced width and/or reduced height relative to the plenum at the active areas. The reduced width and/or height of the plenum, and exterior dimensions of cold plate, at the non-active areas allow the non-active areas to flex to accommodate surface variations of the electronics assembly. The reduced width and/or height non-active areas can be specifically shaped to fit between physical features of the electronics assembly.

  16. Plating laboratory

    International Nuclear Information System (INIS)

    Seamster, A.G.; Weitkamp, W.G.

    1984-01-01

    The lead plating of the prototype resonator has been conducted entirely in the plating laboratory at SUNY Stony Brook. Because of the considerable cost and inconvenience in transporting personnel and materials to and from Stony Brook, it is clearly impractical to plate all the resonators there. Furthermore, the high-beta resonator cannot be accommodated at Stony Brook without modifying the set up there. Consequently the authors are constructing a plating lab in-house

  17. Percutaneous Transhepatic Cholangiography

    African Journals Online (AJOL)

    1974-03-30

    Mar 30, 1974 ... Percutaneous transhepatic cholangiography can play a major role in expediting the early diagnosis of surgically correctable jaundice. The need for this is emphasised by the fact that in a group of 46 patients the delay between the onset of jaundice and diagnosis ranged from 20 to 90 days. Transhepatic ...

  18. 49 CFR 236.338 - Mechanical locking required in accordance with locking sheet and dog chart.

    Science.gov (United States)

    2010-10-01

    ... locking sheet and dog chart. 236.338 Section 236.338 Transportation Other Regulations Relating to... in accordance with locking sheet and dog chart. Mechanical locking shall be in accordance with locking sheet and dog chart currently in effect. ...

  19. Percutaneous distraction lengthening in brachymetacarpia.

    Science.gov (United States)

    Volpi, Alexander D; Fragomen, Austin T

    2011-08-08

    Brachymetacarpia is a condition manifesting a shortened metacarpal that is caused by early closure of the epiphyseal plate and believed to arise idiopathically. The correction for brachymetacarpia is usually for cosmetic reasons as brachymetacarpia does not impair function. The literature indicates several different approaches to lengthening digits, including single-stage lengthening and rapid distraction lengthening with a bone graft. However, gradual distraction is the preferred method due to excellent cosmetic outcomes and few postoperative complications. This article reports a case of brachymetacarpia treated with distraction lengthening using a minimally invasive, percutaneous approach. A 16-year-old girl presented with a shortened left ring finger and underwent surgery to correct the deformity. The left ring finger measured 12 mm shorter than her right ring finger; however, there was normal mobility at the joints. In the operating room, an external fixator was attached using 4 self-drilling, self-tapping pins through several 3-mm skin incisions. The total fixation time was 14 weeks; however, the achieved length of 12 mm was achieved 6 weeks postoperatively. The healing index of the fixation period was 81 days/cm. The postoperative course and fixation period were uneventful, with no complications except for 2 pin infections that were treated with oral antibiotics. The method of gradual distraction lengthening in this case successfully achieved the desired length and yielded an excellent cosmetic result. Copyright 2011, SLACK Incorporated.

  20. 49 CFR 236.330 - Locking dog of switch-and-lock movement.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...

  1. Breaking Carbon Lock-in

    DEFF Research Database (Denmark)

    Driscoll, Patrick Arthur

    2014-01-01

    This central focus of this paper is to highlight the ways in which path dependencies and increasing returns (network effects) serve to reinforce carbon lock-in in large-scale road transportation infrastructure projects. Breaking carbon lock-in requires drastic changes in the way we plan future...

  2. Percutaneous lumbar discectomy

    International Nuclear Information System (INIS)

    Xiao Chengjiang; Su Huanbin; Xu Sui; He Xiaofeng; Li Yanhao

    2004-01-01

    Objective: To probe the therapeutic effects, indications and safety of the percutaneous lumbar discectomy (PLDP). Methods: To ameliorate percutaneous punctured route based on classic PLD and modified jaw structure of pulpiform nacleus forceps, with statistic analysis of the therapeutic results of 352 cases of patient undergone PLDP and follow up ranging from 6 to 38 months retrospectively. Results: The effective ratios were excellent in 45.5%, good for 45.4% and bad in 9.1%. 44 of 352 cases with pulps prolapse were cured. No intervertebral inflammation and paradisc hematoma took place. One case complicated with cauda equina injury and 4 cases with appliances broken inside the disc. Conclusions: PLDP is effective and safe, not only adaptive to the contained disc herniation, but also for noncontained herniation. (authors)

  3. Ameliorative percutaneous lumbar discectomy

    International Nuclear Information System (INIS)

    Xiao Chengjiang; Su Huanbin; He Xiaofeng; Li Yanhao

    2005-01-01

    Objective: To ameliorate the percutaneous lumbar discectomy (APLD) for improving the effectiveness and amplifying the indicative range of PLD. Methods: To ameliorate percutaneous punctured route based on classic PLD and discectomy of extracting pulp out of the herniated disc with special pulpforceps. The statistical analysis of the therapeutic results on 750 disc protrusions of 655 cases undergone APLD following up from 6 to 54 months retrospectively. Results: The effective ratios were excellent in 40.2%, good for 46.6% and bad of 13.3%. No occurrance of intervertebral inflammation and paradiscal hematoma, there were only 1 case complicated with injuried cauda equina, and 4 cases with broken appliance within disc. Conclusions: APLD is effective and safe, not only indicative for inclusion disc herniation, but also for noninclusion herniation. (authors)

  4. Percutaneous transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Przybojewski, J.Z.; Weich, H.F.H.

    1984-01-01

    The purpose of this article is to review PTCA, percutaneous transluminal coronary angioplasty, which can be considered to be a truly revolutionary and fairly simple invasive form of intervention to atherosclerotic obstruction. The 'epidemic' of IHD, ischaemic heart disease, in the Republic of South Africa calls for the employment of this technique, which has already been carried out in a few teaching hospitals in this country. Very recently, modified balloon dilatation catheters have been used percutaneously in the non-operative transluminal correction of congenital coarctation of the aorta in infants and children, congenital pulmonary value stenosis, and hypoplasia and stenosis of the pulmonary arteries. It has also been employed for PTCA and for the simultaneous occlusion of coronary-bronchial artery anastomosis using a detachable balloon. The isotopes thallium 201 and technetium 99 were also used in scintiscanning

  5. Homodyne locking of a squeezer.

    Science.gov (United States)

    Heurs, M; Petersen, I R; James, M R; Huntington, E H

    2009-08-15

    We report on the successful implementation of an approach to locking the frequencies of an optical parametric oscillator (OPO)-based squeezed-vacuum source and its driving laser. The technique allows the simultaneous measurement of the phase shifts induced by a cavity, which may be used for the purposes of frequency locking, as well as the simultaneous measurement of the sub-quantum-noise-limited (sub-QNL) phase quadrature output of the OPO. The homodyne locking technique is cheap, easy to implement, and has the distinct advantage that subsequent homodyne measurements are automatically phase locked. The homodyne locking technique is also unique in that it is a sub-QNL frequency discriminator.

  6. Payload Launch Lock Mechanism

    Science.gov (United States)

    Young, Ken (Inventor); Hindle, Timothy (Inventor)

    2014-01-01

    A payload launch lock mechanism includes a base, a preload clamp, a fastener, and a shape memory alloy (SMA) actuator. The preload clamp is configured to releasibly restrain a payload. The fastener extends, along an axis, through the preload clamp and into the base, and supplies a force to the preload clamp sufficient to restrain the payload. The SMA actuator is disposed between the base and the clamp. The SMA actuator is adapted to receive electrical current and is configured, upon receipt of the electrical current, to supply a force that causes the fastener to elongate without fracturing. The preload clamp, in response to the fastener elongation, either rotates or pivots to thereby release the payload.

  7. 49 CFR 236.765 - Locking, mechanical.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, mechanical. 236.765 Section 236.765 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, mechanical. An arrangement of locking bars, dogs, tappets, cross locking and other apparatus by...

  8. Escaping carbon lock-in

    International Nuclear Information System (INIS)

    Unruh, G.C.

    2002-01-01

    This article explores the climate policy implications of the arguments made in ''Understanding carbon lock-in'' (Unruh, 2000), which posited that industrial countries have become locked-into fossil fuel-based energy systems through path dependent processes driven by increasing returns to scale. Carbon lock-in arises through technological, organizational, social and institutional co-evolution, ''culminating'' in what was termed as techno-institutional complex (TIC). In order to resolve the climate problem, an escape from the lock-in condition is required. However, due to the self-referential nature of TIC, escape conditions are unlikely to be generated internally and it is argued here that erogenous forces are probably required. (author)

  9. Globalizing carbon lock-in

    International Nuclear Information System (INIS)

    Unruh, Gregory C.; Carrillo-Hermosilla, Javier

    2006-01-01

    This paper extends the arguments surrounding carbon lock-in elaborated in Unruh (Energy Policy 28 (2000) 817; 30 (2002) 317) to countries currently undergoing industrialization. It argues that, for numerous reasons, industrializing countries are unlikely to leapfrog carbon intensive energy development. On the contrary, carbon lock-in may be globalizing and could further constrain climate change mitigation options. It is then argued that many policy recommendations ignore carbon lock-in, possibly limiting their potential for successful implementation. The paper then discusses four policy approaches that appear to have advantages given lock-in conditions. It is recognized, however, that relative ease of implementation does not necessarily equate with superiority. Instead, it is merely a path dependent outcome of past development decisions. Pursuing policies on the basis of relative implementation ease may help address the issue of climate change, but could also result in sub-optimal outcomes along other dimensions of sustainable development

  10. Research of mechanism of density lock

    International Nuclear Information System (INIS)

    Wang Shengfei; Yan Changqi; Gu Haifeng

    2010-01-01

    Mechanism of density lock was analyzed according to the work conditions of density lock. The results showed that: the stratification with no disturbance satisfied the work conditions of density lock; fluids between the stratification were not mixed at the condition of connected to each other; the density lock can be open automatically by controlled the pressure balance at the stratification. When disturbance existed, the stratification might be broken and mass would be transferred by convection. The stability of stratification can be enhanced by put the special structure in density lock to ensure the normal work of density lock. At last, the minimum of heat loss in density lock was also analyzed. (authors)

  11. Hew Locke: House of Cards

    OpenAIRE

    Reckitt, Helena; Joyce, Julie; Locke, Hew

    2004-01-01

    ‘Hew Locke: House of Cards’ featured a selection of the artist's portraits of British royalty in various media, and his response to other trappings of the monarchy and empire. The show included works previously exhibited at the Luckman Gallery, Los Angeles, in tandem with a newly commissioned coat of arms, and other recent works. \\ud \\ud Locke draws from everyday sources, ranging from items found in London's Brixton Market to discount fabric shops and thrift stores. Other sources of inspirati...

  12. John locke on personal identity.

    Science.gov (United States)

    Nimbalkar, Namita

    2011-01-01

    John Locke speaks of personal identity and survival of consciousness after death. A criterion of personal identity through time is given. Such a criterion specifies, insofar as that is possible, the necessary and sufficient conditions for the survival of persons. John Locke holds that personal identity is a matter of psychological continuity. He considered personal identity (or the self) to be founded on consciousness (viz. memory), and not on the substance of either the soul or the body.

  13. John Locke on Personal Identity**

    OpenAIRE

    Nimbalkar, Namita

    2011-01-01

    John Locke speaks of personal identity and survival of consciousness after death. A criterion of personal identity through time is given. Such a criterion specifies, insofar as that is possible, the necessary and sufficient conditions for the survival of persons. John Locke holds that personal identity is a matter of psychological continuity. He considered personal identity (or the self) to be founded on consciousness (viz. memory), and not on the substance of either the soul or the body.

  14. [Ultrasound guided percutaneous nephrolithotripsy].

    Science.gov (United States)

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  15. Outdraft at Lock Approach, Tom Bevill Lock and Dam, Alabama: Hydraulic Model Investigation

    National Research Council Canada - National Science Library

    Lynch, Gary

    2001-01-01

    .... The lock is connected to the dam with a 150-ft abutment wall. A strong crosscurrent or outdraft existing in and around the upstream lock entrance causes difficulty for tow traffic navigating the lock...

  16. Assessing carbon lock-in

    International Nuclear Information System (INIS)

    Erickson, Peter; Kartha, Sivan; Lazarus, Michael; Tempest, Kevin

    2015-01-01

    The term ‘carbon lock-in’ refers to the tendency for certain carbon-intensive technological systems to persist over time, ‘locking out’ lower-carbon alternatives, and owing to a combination of linked technical, economic, and institutional factors. These technologies may be costly to build, but relatively inexpensive to operate and, over time, they reinforce political, market, and social factors that make it difficult to move away from, or ‘unlock’ them. As a result, by investing in assets prone to lock-in, planners and investors restrict future flexibility and increase the costs of achieving agreed climate protection goals. Here, we develop a straight-forward approach to assess the speed, strength, and scale of carbon lock-in for major energy-consuming assets in the power, buildings, industry, and transport sectors. We pilot the approach at the global level, finding that carbon lock-in is greatest, globally, for coal power plants, gas power plants, and oil-based vehicles. The approach can be readily applied at the national or regional scale, and may be of particular relevance to policymakers interested in enhancing flexibility in their jurisdictions for deeper emissions cuts in the future, and therefore in limiting the future costs associated with ‘stranded assets’. (letter)

  17. Percutaneous endoscopic gastrostomy.

    Science.gov (United States)

    Gay, F; el Nawar, A; Van Gossum, A

    1992-01-01

    From March 87 to March 92, fifty eight patients were referred to our department for percutaneous endoscopic gastrostomy (PEG). The modality of the feeding tube insertion is described. The most common indications for placement were neurologic disorders in 62% of the cases (n = 36) and malignant diseases in 32% (n = 19). The success rate of the technique was 98.3% (n = 57). No procedure-related mortality was observed. A low rate of major complication (1.7%) and minor complication (10.5%) was noted. Feeding tubes were removed in 21% of patients (n = 12); none of them with malignant disease. Survival curve analysis demonstrated that 50% of patients died within 3 months of PEG placement. Such results raise questions about the selection of patients undergoing PEG. Our experience of patients undergoing PEG. Our experience suggests that PEG is easy and safe, even in debilitated patients, having an acceptable life expectancy.

  18. Percutaneous Nephrolithotomy in Children

    Directory of Open Access Journals (Sweden)

    Romano T. DeMarco

    2011-01-01

    Full Text Available The surgical management of pediatric stone disease has evolved significantly over the last three decades. Prior to the introduction of shockwave lithotripsy (SWL in the 1980s, open lithotomy was the lone therapy for children with upper tract calculi. Since then, SWL has been the procedure of choice in most pediatric centers for children with large renal calculi. While other therapies such as percutaneous nephrolithotomy (PNL were also being advanced around the same time, PNL was generally seen as a suitable therapy in adults because of the concerns for damage in the developing kidney. However, recent advances in endoscopic instrumentation and renal access techniques have led to an increase in its use in the pediatric population, particularly in those children with large upper tract stones. This paper is a review of the literature focusing on the indications, techniques, results, and complications of PNL in children with renal calculi.

  19. Outcome of Percutaneous Nephrolithotomy

    International Nuclear Information System (INIS)

    Ali, S.; Kumar, N.; Baloch, U.

    2014-01-01

    Objective: To assess the implementation of Percutaneous Nephrolithotomy (PCNL) in renal stone management and evaluate the factors for efficacy and safety of PCNL. Study Design: Case series. Place and Duration of Study: Department of Urology at Jinnah Postgraduate Medical Centre, Karachi, from January 2008 to December 2011. Methodology: Patients aged above 12 years of age, irrespective of gender with normal renal function, mean stone size > 2 cm, lower pole stones > 1 cm, and ESWL failure were selected. After the procedure, on the first postoperative day, a plain abdominal radiograph was obtained to verify stone clearance. A nephrostomy tube was clamped overnight and subsequently removed when no residual stone which needs second sitting was seen. Results: In 175 patients, 62.86% (n=110) were male and the mean age was 35 A +- 9.56 years. One hundred and seventeen (66.85%) patients were primarily stone free and 13.71% (n=24) patients needed a second look procedure, thus, a total of 80.57% (n=141) patients were stone free in the same admission. Complications included failure in 4.0% (n=7) patients, bleeding in 8.57% (n=15) patients, a small residual stone in 15.43% (n=27) patients; and puncture site pain almost in every patient. Transient fever occurred in 55.43% (n=97) patients, urinary leakage in 8.57% (n=15) patients, urinary tract infections in 5.14% (n=9) patients, ureteric colic in 3.43% (n=6) patients, colonic injury in 0.57% (n=1) patient; and nephrectomy was required in 0.57% (n=1) patient due to severe bleeding. One patient (0.57%) expired due to anaesthesia complications. Conclusion: Percutaneous nephrolithotomy (PCNL) has a good success rate. There is minimal blood loss, and few major complications. (author)

  20. Advances in percutaneous stone surgery

    OpenAIRE

    Hartman, Christopher; Gupta, Nikhil; Leavitt, David; Hoenig, David; Okeke, Zeph; Smith, Arthur

    2015-01-01

    Treatment of large renal stones has changed considerably in recent years. The increasing prevalence of nephrolithiasis has mandated that urologists perform more surgeries for large renal calculi than before, and this has been met with improvements in percutaneous stone surgery. In this review paper, we examine recent developments in percutaneous stone surgery, including advances in diagnosis and preoperative planning, renal access, patient position, tract dilation, nephroscopes, lithotripsy, ...

  1. Advances in percutaneous stone surgery.

    Science.gov (United States)

    Hartman, Christopher; Gupta, Nikhil; Leavitt, David; Hoenig, David; Okeke, Zeph; Smith, Arthur

    2015-01-01

    Treatment of large renal stones has changed considerably in recent years. The increasing prevalence of nephrolithiasis has mandated that urologists perform more surgeries for large renal calculi than before, and this has been met with improvements in percutaneous stone surgery. In this review paper, we examine recent developments in percutaneous stone surgery, including advances in diagnosis and preoperative planning, renal access, patient position, tract dilation, nephroscopes, lithotripsy, exit strategies, and post-operative antibiotic prophylaxis.

  2. Coupled optical resonance laser locking.

    Science.gov (United States)

    Burd, S C; du Toit, P J W; Uys, H

    2014-10-20

    We have demonstrated simultaneous laser frequency stabilization of a UV and IR laser, to coupled transitions of ions in the same spectroscopic sample, by detecting only the absorption of the UV laser. Separate signals for locking the different lasers are obtained by modulating each laser at a different frequency and using lock-in detection of a single photodiode signal. Experimentally, we simultaneously lock a 369 nm and a 935 nm laser to the (2)S(1/2) → (2)(P(1/2) and (2)D(3/2) → (3)D([3/2]1/2) transitions, respectively, of Yb(+) ions generated in a hollow cathode discharge lamp. Stabilized lasers at these frequencies are required for cooling and trapping Yb(+) ions, used in quantum information and in high precision metrology experiments. This technique should be readily applicable to other ion and neutral atom systems requiring multiple stabilized lasers.

  3. Automatic locking knee brace joint

    Science.gov (United States)

    Weddendorf, Bruce (Inventor)

    1995-01-01

    This invention is an apparatus for controlling the pivotal movement of a knee brace comprising a tang-and-clevis joint that has been uniquely modified. Both the tang and the clevis have a set of teeth that, when engaged, can lock the tang and the clevis together. In addition, the tang is biased away from the clevis. Consequently, when there is no axial force (i.e., body weight) on the tang, the tang is free to pivot within the clevis. However, when an axial force is exerted on the tang, the tang is pushed into the clevis, both sets of teeth engage, and the tang and the clevis lock together.

  4. DYNAMIC RESPONSE OF THICK PLATES ON TWO PARAMETER ELASTIC FOUNDATION UNDER TIME VARIABLE LOADING

    OpenAIRE

    Ozgan, Korhan; Daloglu, Ayse T.

    2014-01-01

    In this paper, behavior of foundation plates with transverse shear deformation under time variable loading is presented using modified Vlasov foundation model. Finite element formulation of thick plates on elastic foundation is derived by using an 8-noded finite element based on Mindlin plate theory. Selective reduced integration technique is used to avoid shear locking problem which arises when smaller plate thickness is considered for the evaluation of the stiffness matrices. After comparis...

  5. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    Science.gov (United States)

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-11-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  6. The variable finesse locking technique

    International Nuclear Information System (INIS)

    Acernese, F; Al-Shourbagy, M

    2006-01-01

    Virgo is a power recycled Michelson interferometer, with 3 km long Fabry-Perot cavities in the arms. The locking of the interferometer has been obtained with an original lock acquisition technique. The main idea is to lock the instrument away from its working point. Lock is obtained by misaligning the power recycling mirror and detuning the Michelson from the dark fringe. In this way, a good fraction of light escapes through the antisymmetric port and the power build-up inside the recycling cavity is extremely low. The benefit is that all the degrees of freedom are controlled when they are almost decoupled, and the linewidth of the recycling cavity is large. The interferometer is then adiabatically brought on to the dark fringe. This technique is referred to as variable finesse, since the recycling cavity is considered as a variable finesse Fabry-Perot. This technique has been widely tested and allows us to reach the dark fringe in few minutes, in an essentially deterministic way

  7. Coupled optical resonance laser locking

    CSIR Research Space (South Africa)

    Burd, CC

    2014-10-01

    Full Text Available We have demonstrated simultaneous laser frequency stabilization of a UV and IR laser, to coupled transitions of ions in the same spectroscopic sample, by detecting only the absorption of the UV laser. Separate signals for locking the different...

  8. Advances phase-lock techniques

    CERN Document Server

    Crawford, James A

    2008-01-01

    From cellphones to micrprocessors, to GPS navigation, phase-lock techniques are utilized in most all modern electronic devices. This high-level book takes a systems-level perspective, rather than circuit-level, which differentiates it from other books in the field.

  9. 49 CFR 236.705 - Bar, locking.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Bar, locking. 236.705 Section 236.705..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.705 Bar, locking. A bar in an interlocking machine to which the locking dogs are attached. ...

  10. Bilateral locked facets in the thoracic spine

    NARCIS (Netherlands)

    M.H.A. Willems; Braakman, R. (Reinder); B. van Linge (Bert)

    1984-01-01

    textabstractTwo cases of traumatic bilateral locked facets in the thoracic spine are reported. Both patients had only minor neurological signs. They both made a full neurological recovery after surgical reduction of the locked facets. Bilateral locked facets are very uncommon in the thoracic spine.

  11. 49 CFR 236.761 - Locking, electric.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, electric. 236.761 Section 236.761 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, electric. The combination of one or more electric locks and controlling circuits by means of...

  12. 49 CFR 236.105 - Electric lock.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock. 236.105 Section 236.105 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION...: All Systems Inspections and Tests; All Systems § 236.105 Electric lock. Electric lock, except forced...

  13. 49 CFR 236.757 - Lock, electric.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lock, electric. 236.757 Section 236.757... Lock, electric. A device to prevent or restrict the movement of a lever, a switch or a movable bridge, unless the locking member is withdrawn by an electrical device, such as an electromagnet, solenoid or...

  14. 49 CFR 236.768 - Locking, time.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, time. 236.768 Section 236.768... Locking, time. A method of locking, either mechanical or electrical, which, after a signal has been caused to display an aspect to proceed, prevents, until after the expiration of a predetermined time...

  15. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  16. Duodenal perforation during percutaneous nephrolithotomy (PCNL ...

    African Journals Online (AJOL)

    A. Bansal

    2016-06-03

    Jun 3, 2016 ... Calculus;. Duodenum;. Injury;. Paediatric;. Percutaneous nephrolithotomy. Abstract. Introduction: Colonic perforations are known complications of percutaneous nephrolithotomy (PCNL). However, to the best of our knowledge, small bowel perforation has rarely been reported.. Observation: We report the ...

  17. Tidal locking of habitable exoplanets

    Science.gov (United States)

    Barnes, Rory

    2017-12-01

    Potentially habitable planets can orbit close enough to their host star that the differential gravity across their diameters can produce an elongated shape. Frictional forces inside the planet prevent the bulges from aligning perfectly with the host star and result in torques that alter the planet's rotational angular momentum. Eventually the tidal torques fix the rotation rate at a specific frequency, a process called tidal locking. Tidally locked planets on circular orbits will rotate synchronously, but those on eccentric orbits will either librate or rotate super-synchronously. Although these features of tidal theory are well known, a systematic survey of the rotational evolution of potentially habitable exoplanets using classic equilibrium tide theories has not been undertaken. I calculate how habitable planets evolve under two commonly used models and find, for example, that one model predicts that the Earth's rotation rate would have synchronized after 4.5 Gyr if its initial rotation period was 3 days, it had no satellites, and it always maintained the modern Earth's tidal properties. Lower mass stellar hosts will induce stronger tidal effects on potentially habitable planets, and tidal locking is possible for most planets in the habitable zones of GKM dwarf stars. For fast-rotating planets, both models predict eccentricity growth and that circularization can only occur once the rotational frequency is similar to the orbital frequency. The orbits of potentially habitable planets of very late M dwarfs ([InlineEquation not available: see fulltext.]) are very likely to be circularized within 1 Gyr, and hence, those planets will be synchronous rotators. Proxima b is almost assuredly tidally locked, but its orbit may not have circularized yet, so the planet could be rotating super-synchronously today. The evolution of the isolated and potentially habitable Kepler planet candidates is computed and about half could be tidally locked. Finally, projected TESS planets

  18. 49 CFR 236.766 - Locking, movable bridge.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, movable bridge. 236.766 Section 236.766... Locking, movable bridge. The rail locks, bridge locks, bolt locks, circuit controllers, and electric locks used in providing interlocking protection at a movable bridge. ...

  19. Safe percutaneous suprapubic catheterisation.

    Science.gov (United States)

    Goyal, N K; Goel, A; Sankhwar, S N

    2012-11-01

    We describe our technique of percutaneous suprapubic catheter insertion with special reference to steps that help to avoid common complications of haematuria and catheter misplacement. The procedure is performed using a stainless steel reusable trocar under local infiltrative anaesthesia, usually at the bedside. After clinical confirmation of a full bladder, the trocar is advanced into the bladder through a skin incision. Once the bladder is entered, the obturator is removed and the assistant inserts a Foley catheter followed by rapid balloon inflation. Slight traction is applied to the catheter for about five minutes. Patients with previous lower abdominal surgery, an inadequately distended bladder or acute pelvic trauma do not undergo suprapubic catheterisation using this method. The procedure was performed in 72 men (mean age: 42.4 years, range: 18-78 years) with urinary retention with a palpable bladder. The average duration of the procedure was less than five minutes. No complications were noted in any of the patients. Trocar suprapubic catheter insertion is a safe and effective bedside procedure for emergency bladder drainage and can be performed by resident surgeons. The common complications associated with the procedure can be avoided with a few careful steps.

  20. [Comparative study on the strength of different mechanisms of operation of multidirectionally angle-stable distal radius plates].

    Science.gov (United States)

    Rausch, S; Hoffmeier, K; Gueorguiev, B G; Klos, K; Gras, F; Hofmann, G O; Mückley, T

    2011-12-01

    Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The present study was performed to investigate the strength of polyaxial locking interfaces of distal radius plates. We tested the polyaxial interfaces of 3 different distal radius plates (2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate, Synthes, Palmar Classic, Königsee Implantate and VariAx Plate Stryker). The strength of 0° and 10° screw locking angle was obtained during static loading. The strength of Palmar Classic with a 0° locking angle is significantly the best of all tested systems. With a 10° locking angle there is no significant difference between Palmar Classic, Two column Plate and VariAx Plate. The strength of polyaxial interfaces differs between the tested systems. A reduction of ultimate strength is due to increases of screw locking angle. The design of polyaxial locking interfaces should be investigated in human bone models. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Lung abscess; Percutaneous catheter therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ha, H.K. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Kang, M.W. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Park, J.M. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Yang, W.J. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Shinn, K.S. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Bahk, Y.W. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of))

    1993-07-01

    Lung abscess was successfully treated with percutaneous drainage in 5 of 6 patients. Complete abscess resolution occurred in 4 patients, partial resolution in one, and no response in one. The duration of drainage ranged from 7 to 18 days (mean 15.5 days) in successful cases. The failure of drainage in one neurologicall impaired patient was attributed to persistent aspiration. In 2 patients, concurrent pleural empyema was also cured. CT provided the anatomic details necessary for choosing the puncture site and avoiding puncture of the lung parenchyma. Percutaneous catheter drainage is a safe and effective method for treating lung abscess. (orig.).

  2. Percutaneous drainage of lung abscess

    Energy Technology Data Exchange (ETDEWEB)

    Ri, Jong Min; Kim, Yong Joo; Kang, Duk Sik [Kyung-Pook National University Hospital, Daegu (Korea, Republic of)

    1992-05-15

    Medical treatment using antibiotics and postural drainage has been widely adopted as a treatment method of pulmonary abscess, accompanied by surgical methods in cases intractable to drug therapy. However long-term therapy may be required, and the tolerance of organisms to antibiotics or other complications are apt to be encountered, during medical treatment. To shorten the convalescent period or to decrease the risk of invasive procedures, rather simple and relatively easy interventional techniques such as transbronchial or percutaneous catheter drainage have been successfully tried. We have performed 12 cases of percutaneous drainages of lung abscesses under fluoroscope guidance. This report is on the results of this procedure.

  3. Percutaneous drainage of lung abscess

    International Nuclear Information System (INIS)

    Ri, Jong Min; Kim, Yong Joo; Kang, Duk Sik

    1992-01-01

    Medical treatment using antibiotics and postural drainage has been widely adopted as a treatment method of pulmonary abscess, accompanied by surgical methods in cases intractable to drug therapy. However long-term therapy may be required, and the tolerance of organisms to antibiotics or other complications are apt to be encountered, during medical treatment. To shorten the convalescent period or to decrease the risk of invasive procedures, rather simple and relatively easy interventional techniques such as transbronchial or percutaneous catheter drainage have been successfully tried. We have performed 12 cases of percutaneous drainages of lung abscesses under fluoroscope guidance. This report is on the results of this procedure

  4. Plate tectonics

    Digital Repository Service at National Institute of Oceanography (India)

    Chaubey, A.K.

    's continental drift theory was later disproved, it was one of the first times that the idea of crustal movement had been introduced to the scientific community; and it has laid the groundwork for the development of modern plate tectonics. In the early... of the structure of the atom was to physical sciences and the theory of evolution was to the life sciences. Tectonics is the study of the forces within the Earth that give rise to continents, ocean basins, mountain ranges, earthquake belts and other large-scale...

  5. Create Your Plate

    Medline Plus

    Full Text Available ... Plate Share Create Your Plate ! Share: Seven Simple Steps to Create Your Plate It's simple and effective ... foods within each food category. Try these seven steps to get started: Using your dinner plate, put ...

  6. Performance of arm locking in LISA

    International Nuclear Information System (INIS)

    McKenzie, Kirk; Spero, Robert E.; Shaddock, Daniel A.

    2009-01-01

    For the Laser Interferometer Space Antenna (LISA) to reach its design sensitivity, the coupling of the free-running laser frequency noise to the signal readout must be reduced by more than 14 orders of magnitude. One technique employed to reduce the laser frequency noise will be arm locking, where the laser frequency is locked to the LISA arm length. In this paper we detail an implementation of arm locking. We investigate orbital effects (changing arm lengths and Doppler frequencies), the impact of errors in the Doppler knowledge that can cause pulling of the laser frequency, and the noise limit of arm locking. Laser frequency pulling is examined in two regimes: at lock acquisition and in steady state. The noise performance of arm locking is calculated with the inclusion of the dominant expected noise sources: ultrastable oscillator (clock) noise, spacecraft motion, and shot noise. We find that clock noise and spacecraft motion limit the performance of dual arm locking in the LISA science band. Studying these issues reveals that although dual arm locking [A. Sutton and D. A. Shaddock, Phys. Rev. D 78, 082001 (2008)] has advantages over single (or common) arm locking in terms of allowing high gain, it has disadvantages in both laser frequency pulling and noise performance. We address this by proposing a modification to the dual arm-locking sensor, a hybrid of common and dual arm-locking sensors. This modified dual arm-locking sensor has the laser frequency pulling characteristics and low-frequency noise coupling of common arm locking, but retains the control system advantages of dual arm locking. We present a detailed design of an arm-locking controller and perform an analysis of the expected performance when used with and without laser prestabilization. We observe that the sensor phase changes beneficially near unity-gain frequencies of the arm-locking controller, allowing a factor of 10 more gain than previously believed, without degrading stability. With a time

  7. Active locking and entanglement in type II optical parametric oscillators

    Science.gov (United States)

    Ruiz-Rivas, Joaquín; de Valcárcel, Germán J.; Navarrete-Benlloch, Carlos

    2018-02-01

    Type II optical parametric oscillators are amongst the highest-quality sources of quantum-correlated light. In particular, when pumped above threshold, such devices generate a pair of bright orthogonally-polarized beams with strong continuous-variable entanglement. However, these sources are of limited practical use, because the entangled beams emerge with different frequencies and a diffusing phase difference. It has been proven that the use of an internal wave-plate coupling the modes with orthogonal polarization is capable of locking the frequencies of the emerging beams to half the pump frequency, as well as reducing the phase-difference diffusion, at the expense of reducing the entanglement levels. In this work we characterize theoretically an alternative locking mechanism: the injection of a laser at half the pump frequency. Apart from being less invasive, this method should allow for an easier real-time experimental control. We show that such an injection is capable of generating the desired phase locking between the emerging beams, while still allowing for large levels of entanglement. Moreover, we find an additional region of the parameter space (at relatively large injections) where a mode with well defined polarization is in a highly amplitude-squeezed state.

  8. Centering and fixing device of a control rod guide flange on a nuclear reactor core plate

    International Nuclear Information System (INIS)

    Chevereau, G.

    1990-01-01

    The device comprises at least two pins diametrally opposite entering into holes in the core plate and self locking pads sliding into bores in the flange. These pads have a command mechanism blocking the lateral displacement of the pads on the plate [fr

  9. Is John Locke a democrat?

    DEFF Research Database (Denmark)

    Svensson, Palle

      Over recent years there has been a tendency to present John Locke as an equalitarian democrat (Ashcraft) and being close to the political views of the levellers (Waldron). This is not a completely new interpretation (Kendall, 1941), but contrasts with the prevalent view presented in textbooks (......, criteria for a democratic process, and the institutions of polyarchy. The conclusion has implications for the relationship between political liberalism and constitutionalism on the one hand and democracy on the other....

  10. Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures.

    Science.gov (United States)

    Zettl, Ralph; Müller, Thorben; Topp, Tobias; Lewan, Ulrike; Krüger, Antonio; Kühne, Christian; Ruchholtz, Steffen

    2011-08-01

    The development of locking plate systems has led to polyaxial screws and new plate designs. This study compares monoaxial head locking screws (PHILOS© by Synthes) and a new generation of polyaxial locking screws (NCB-LE© by Zimmer) with respect to biomechanical stability. On nine pairs of randomised formalin fixed humerus specimens, standardised osteotomies and osteosyntheses with nine monoaxial (group A) und nine polyaxial (group B) plate/screw systems were performed. A material testing machine by Instron (M-10 14961-DE) was used for cyclic stress tests and crash tests until defined breakup criteria as endpoints were reached. After axial cyclic stress 200 times at 90 N, plastic deformation was 1.02 mm in group A and 1.25 mm in group B. After the next cycle using 180 N the additional deformation averaged 0.23 mm in group A and 0.39 mm in group B. The deformation using 450 N was 0.72 mm in group A compared to 0.92 mm in group B. The final full power test resulted in a deformation average of 0.49 mm in group A and 0.63 mm in group B after 2,000 cycles using 450 N. When reaching the breakup criteria the plastic deformation of the NCB plate was 9.04 mm on average. The PHILOS plate was similarly deformed by 9.00 mm. As a result of the crash test, in group A the screws pulled out of the humeral head four times whereas the shaft broke one time and another time the implant was ripped out. The gap was closed four times. In group B, there were three cases of screw cut-through, four shaft fractures/screw avulsions from the shaft and two cases of gap closure. The two systems resist the cyclic duration tests and the increasing force tests in a similar manner. The considerable clinical benefits of the polyaxial system are enhanced by equal biomechanical performance.

  11. [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock].

    Science.gov (United States)

    Hakimi, M; Jungbluth, P; Gehrmann, S; Nowak, J; Windolf, J; Wild, M

    2010-03-01

    Due to advances in the development of the unidirectional locking plates there is now an increased use of multidirectional palmar locking plates in the treatment of distal radius factures. The purpose of this study was to evaluate a possible improvement of the treatment and results. This prospective cohort study investigated 40 patients with C1 and C2 Colles' fractures who had been treated with unidirectional and multidirectional locking plates. The average time for the follow-up examinations was 12.3 months (range 12-15 months) after surgery. The intra-operative functional (neutral-zero method), radiological and subjective (DASH score, VAS) results were evaluated. The intra-operative fluoroscopy time of the unidirectional group was 58 s shorter compared to the multidirectional group. All fractures healed without any complication. The radiological, subjective (DASH score) and objective results for both groups were good and showed no differences. Unidirectional palmar locking plates are equally suited for the therapy of C1 and C2 fractures as multidirectional palmar locking plates but multidirectional plates require a longer fluoroscopy time.

  12. Robotics in percutaneous cardiovascular interventions.

    Science.gov (United States)

    Pourdjabbar, Ali; Ang, Lawrence; Behnamfar, Omid; Patel, Mitul P; Reeves, Ryan R; Campbell, Paul T; Madder, Ryan D; Mahmud, Ehtisham

    2017-11-01

    The fundamental technique of performing percutaneous cardiovascular (CV) interventions has remained unchanged and requires operators to wear heavy lead aprons to minimize exposure to ionizing radiation. Robotic technology is now being utilized in interventional cardiology partially as a direct result of the increasing appreciation of the long-term occupational hazards of the field. This review was undertaken to report the clinical outcomes of percutaneous robotic coronary and peripheral vascular interventions. Areas covered: A systematic literature review of percutaneous robotic CV interventions was undertaken. The safety and feasibility of percutaneous robotically-assisted CV interventions has been validated in simple to complex coronary disease, and iliofemoral disease. Studies have shown that robotically-assisted PCI significantly reduces operator exposure to harmful ionizing radiation without compromising procedural success or clinical efficacy. In addition to the operator benefits, robotically-assisted intervention has the potential for patient advantages by allowing more accurate lesion length measurement, precise stent placement and lower patient radiation exposure. However, further investigation is required to fully elucidate these potential benefits. Expert commentary: Incremental improvement in robotic technology and telecommunications would enable treatment of an even broader patient population, and potentially provide remote robotic PCI.

  13. Percutaneous nephrolithotomy and its legacy

    NARCIS (Netherlands)

    Skolarikos, A.; Alivizatos, G.; de la Rosette, J. J. M. C. H.

    2005-01-01

    Objective: We review the indications of Percutaneous Nephrolithotomy (PNL), its safety and efficacy when applied to various patient groups as well as the different points of technique, giving emphasis on new tips and ongoing debates. Methods: A literature search was performed using MEDLINE database

  14. Image guided percutaneous splenic interventions

    International Nuclear Information System (INIS)

    Kang, Mandeep; Kalra, Naveen; Gulati, Madhu; Lal, Anupam; Kochhar, Rohit; Rajwanshi, Arvind

    2007-01-01

    Aim: The objective of this study is to evaluate the efficacy and safety of image-guided percutaneous splenic interventions as diagnostic or therapeutic procedures. Materials and methods: We performed a retrospective review of our interventional records from July 2001 to June 2006. Ninety-five image-guided percutaneous splenic interventions were performed after informed consent in 89 patients: 64 men and 25 women who ranged in age from 5 months to 71 years (mean, 38.4 years) under ultrasound (n = 93) or CT (n = 2) guidance. The procedures performed were fine needle aspiration biopsy of focal splenic lesions (n = 78) and aspiration (n = 10) or percutaneous catheter drainage of a splenic abscess (n = 7). Results: Splenic fine needle aspiration biopsy was successful in 62 (83.78%) of 74 patients with benign lesions diagnosed in 43 (58.1%) and malignancy in 19 (25.67%) patients. The most common pathologies included tuberculosis (26 patients, 35.13%) and lymphoma (14 patients, 18.91%). Therapeutic aspiration or pigtail catheter drainage was successful in all (100%) patients. There were no major complications. Conclusions: Image-guided splenic fine needle aspiration biopsy is a safe and accurate technique that can provide a definitive diagnosis in most patients with focal lesions in the spleen. This study also suggests that image-guided percutaneous aspiration or catheter drainage of splenic abscesses is a safe and effective alternative to surgery

  15. Osteosíntesis percutánea con placas volares bloqueadas en fracturas metafisarias distales de radio Descripción de la técnica y resultados preliminares. [Percutaneous volar locked plate fixation in metaphyseal fractures of distal radius: technical description and preliminary results].

    Directory of Open Access Journals (Sweden)

    Natalia del Milagro Gutierrez Olivera

    2016-05-01

    Full Text Available Objetivo Evaluar resultados objetivos y subjetivos obtenidos luego de realizar osteosíntesis con placas en T bloqueadas volares, colocadas con técnica mínimamente invasiva, en fracturas del radio distal con extensión metafisaria. Material y Métodos Evaluación retrospectiva de seis pacientes adultos que presentaron fracturas inestables de radio distal, extra-articulares o articulares parciales, con extensión  metafisaria, tratadas quirúrgicamente con placas en T largas de compresión bloqueadas volares, mediante  técnica mínimamente invasiva, entre 2007 y  2012. Edad promedio 40,6 años. Todas las fracturas fueron cerradas, clasificadas como tipo 23A3 (n: 5 y 23B1 (n: 1 según el Sistema AO/ASIF. Se realizó reducción indirecta de la fractura, bajo visión radioscópica, a través de dos pequeñas incisiones se deslizó en forma percutánea una placa bloqueada volar en T. Se analizaron  parámetros radiológicos (angulación volar, inclinación radial y altura radial, el rango de movimiento y la fuerza. Los resultados subjetivos fueron evaluados usando la Escala de DASH y la Escala Visual Análoga. Resultados Tiempo de consolidaron promedio de 2,3 meses. Los resultados radiográficos no mostraron diferencias significativas entre el primer y el último control radiográfico al año de seguimiento. Flexión y extensión promedio 70° y 60°, pronación y supinación 79° y 80° respectivamente. Fuerza de prensión promedio 78,4%. El score de DASH 19,84 puntos y el EVA 1,5 puntos. Conclusión Las técnicas mínimamente invasivas reducen el daño quirúrgico y complicaciones. Son una opción en pacientes con daño severo de partes blandas, conminución metafisaria y trauma de alta energía. Pequeñas incisiones alejadas del sitio de fractura respetan los tejidos blandos y la biología ósea, contribuyendo a lograr la consolidación. La colocación de placas volares bloqueadas percutáneas es un procedimiento técnicamente demandante; permite obtener fijaciones estables y restaurar la anatomía radial en fracturas de radio distal con extensión metafisaria. El problema más común es la mala alineación ósea.

  16. Extended indications for percutaneous tracheostomy.

    Science.gov (United States)

    Ben Nun, Alon; Altman, Eduard; Best, Lael Anson

    2005-10-01

    In recent years, percutaneous tracheostomy has become a routine practice in many hospitals. In the early publications, most authors considered adverse conditions such as short, fat neck or obesity as relative contraindications whereas cervical injury, coagulopathy, and emergency were regarded as absolute contraindications. More recently, several reports demonstrated the feasibility of percutaneous tracheostomy in patients with some of these contraindications. The aim of this study is to determine the safety and efficacy of percutaneous tracheostomy in conditions commonly referred to as contraindications. Between June 2000 and July 2001, 157 consecutive percutaneous tracheostomy procedures were performed on 154 critically ill adult patients in the general intensive care unit of a major tertiary care facility. The Griggs technique and Portex set were used at the bedside. All procedures were performed by staff thoracic surgeons and anesthesiologists experienced with the technique. Anatomical conditions, presence of coagulopathy and anti-coagulation therapy, demographics, and complication rates were recorded. Five of 157 procedures (154 patients owing to three repeat tracheostomies) had complications. In patients with normal anatomical conditions and coagulation profiles, there was one case of bleeding (50 cc to 120 cc) and one case of mild cellulitis around the stoma. In patients with adverse conditions, there was one case of bleeding (50 cc to 120 cc) and two cases of minor bleeding (< 50 cc). Patients with adverse conditions had a low complication rate similar to patients with normal conditions. For this reason, we believe that percutaneous tracheostomy is indicated in patients with short, fat neck; inability to perform neck extension; enlarged isthmus of thyroid; previous tracheostomy; or coagulopathy and anti-coagulation therapy.

  17. Phase-locked Josephson soliton oscillators

    DEFF Research Database (Denmark)

    Holst, T.; Hansen, Jørn Bindslev; Grønbech-Jensen, N.

    1991-01-01

    Detailed experimental characterization of the phase-locking at both DC and at microwave frequencies is presented for two closely spaced Josephson soliton (fluxon) oscillators. In the phase-locked state, the radiated microwave power exhibited an effective gain. With one common bias source......, a frequency tunability of the phase-locked oscillators up to 7% at 10 GHz was observed. The interacting soliton oscillators were modeled by two inductively coupled nonlinear transmission lines...

  18. Microcontroller-based locking in optics experiments

    International Nuclear Information System (INIS)

    Huang, K.; Le Jeannic, H.; Ruaudel, J.; Morin, O.; Laurat, J.

    2014-01-01

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments

  19. Safety lock for radiography exposure device

    International Nuclear Information System (INIS)

    Gaines, T.M.

    1982-01-01

    A safety lock for securing a radiation source in a radiography exposure device is disclosed. The safety lock prevents the inadvertent extension of the radiation source from the exposure device. The exposure devices are used extensively in industry for nondestructive testing of metal materials for defect. Unnecessary exposure of the radiographer or operator occurs not infrequently due to operator's error in believing that the radiation source is secured in the exposure device when, in fact, it is not. The present invention solves this problem of unnecessary exposure by releasingly trapping the radiation source in the shield of the radiography exposure device each time the source is retracted therein so that it is not inadvertently extended therefrom without the operator resetting the safety lock, thereby releasing the radiation source. Further, the safety lock includes an indicator which indicates when the source is trapped in the exposure device and also when it is untrapped. The safety lock is so designed that it does not prevent the return of the source to the trapped, shielded position in the exposure device. Further the safety lock includes a key means for locking the radiation source in the trapped position. The key means cannot be actuated until said radiation source is in said trapped position to further insure the safety lock cannot be inadvertently locked with the source untrapped and thus still extendable from the exposure device

  20. Phase locking between Josephson soliton oscillators

    DEFF Research Database (Denmark)

    Holst, T.; Hansen, Jørn Bindslev; Grønbech-Jensen, N.

    1990-01-01

    We report observations of phase-locking phenomena between two Josephson soliton (fluxon) oscillators biased in self-resonant modes. The locking strength was measured as a function of bias conditions. A frequency tunability of the phase-locked oscillators up to 7% at 10 GHz was observed. Two coupled...... perturbed sine-Gordon equations were derived from an equivalent circuit consisting of inductively coupled, nonlinear, lossy transmission lines. These equations were solved numerically to find the locking regions. Good qualitative agreement was found between the experimental results and the calculations...

  1. Microcontroller-based locking in optics experiments.

    Science.gov (United States)

    Huang, K; Le Jeannic, H; Ruaudel, J; Morin, O; Laurat, J

    2014-12-01

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments.

  2. Microcontroller-based locking in optics experiments

    Energy Technology Data Exchange (ETDEWEB)

    Huang, K. [Laboratoire Kastler Brossel, UPMC-Sorbonne Universités, CNRS, ENS-PSL Research University, Collège de France, 4 place Jussieu, 75005 Paris (France); State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062 (China); Le Jeannic, H.; Ruaudel, J.; Morin, O.; Laurat, J., E-mail: julien.laurat@upmc.fr [Laboratoire Kastler Brossel, UPMC-Sorbonne Universités, CNRS, ENS-PSL Research University, Collège de France, 4 place Jussieu, 75005 Paris (France)

    2014-12-15

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments.

  3. Double pass locking and spatial mode locking for gravitational wave detectors

    CERN Document Server

    Cusack, B J; Slagmolen, B; Vine, G D; Gray, M B; McClelland, D E

    2002-01-01

    We present novel techniques for overcoming problems relating to the use of high-power lasers in mode cleaner cavities for second generation laser interferometric gravitational wave detectors. Rearranging the optical components into a double pass locking regime can help to protect locking detectors from damage. Modulator thermal lensing can be avoided by using a modulation-free technique such as tilt locking, or its recently developed cousin, flip locking.

  4. Effects of Volar Tilt, Wrist Extension, and Plate Position on Contact Between Flexor Pollicis Longus Tendon and Volar Plate.

    Science.gov (United States)

    Wurtzel, Caroline N Wolfe; Burns, Geoffrey T; Zhu, Andy F; Ozer, Kagan

    2017-12-01

    Volar plates positioned at, or distal to, the watershed line have been shown to have a higher incidence of attritional rupture of the flexor pollicis longus (FPL). In this study, we aimed to evaluate the effect of wrist extension and volar tilt on the contact between the plate and the FPL tendon in a cadaver model. We hypothesized that, following volar plate application, loss of native volar tilt increases the contact between the FPL and the plate at lower degrees of wrist extension. A volar locking plate was applied on 6 fresh-frozen cadavers. To determine the contact between the plate and the FPL tendon, both structures were wrapped with copper wire and circuit conductivity was monitored throughout wrist motion. A lateral wrist radiograph was obtained at each circuit closure, indicating tendon-plate contact. Baseline measurements were obtained with plate positioned at Soong grades 0, 1, and 2. An extra-articular osteotomy was made and contact was recorded at various volar tilt angles (+5°, 0°, -5°, -10°, -15°, and -20°) in 3 different plate positions. A blinded observer measured the degree of wrist extension on all lateral radiographs. Data were analyzed using linear mixed-effects regression model. Plates placed distal to the watershed line had the most contact throughout wrist range of motion. Significantly, less wrist extension was required for contact in wrists with neutral or dorsal tilt and in distally placed volar plates. Volar tilt, wrist extension, and plate position were 3 independent risk factors determining contact between plate and tendon. Loss of volar tilt, increased wrist extension, and higher Soong grade plate position result in greater contact between wire-wrapped FPL tendon and plate. The FPL/plate contact chart generated in this study may be used to assess the risk of rupture in the clinical setting. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Percutaneous cryoablation for hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    Kyoung Doo Song

    2016-12-01

    Full Text Available Local ablation therapy is considered as a conventional treatment option for patients with early stage hepatocellular carcinoma (HCC. Although radiofrequency (RF ablation is widely used for HCC, the use of cryoablation has been increasing as newer and safer cryoablation systems have developed. The thermodynamic mechanism of freezing and thawing used in cryoablation is the Joule-Thomson effect. Cryoablation destroys tissue via direct tissue destruction and vascular-related injury. A few recent comparative studies have shown that percutaneous cryoablation for HCCs is comparable to percutaneous RF ablation in terms of long term therapeutic outcomes and complications. Cryoablation has several advantages over RF ablation such as well visualization of iceball, no causation of severe pain, and lack of severe damage to great vessels and gallbladder. It is important to know the advantages and disadvantages of cryoablation compared with RF ablation for improvement of therapeutic efficacy and safety.

  6. Percutaneous tracheostomy: a comprehensive review

    Science.gov (United States)

    Rashid, Ashraf O.

    2017-01-01

    Tracheostomy is a common procedure. It can be done surgically or percutaneously by dilating the stoma using Seldinger technique. Percutaneous tracheostomy (PT) is now routinely performed by surgeons and non-surgeons such as intensivists and anesthesiologists in the intensive care units (ICU) all over the world. Although obesity, emergent tracheostomy, coagulopathy, inability to extend the neck and high ventilator demand (HVD) were initially thought to be a relative contraindication, recent data suggest safety of PT in these patient population. Ultrasound can be helpful in limited cases to identify the neck structure especially in patients with a difficult anatomy. Bronchoscopy during PT can shorten the duration and avoid complications. PT has favorable complication rate, lower infection rate, shorter procedural duration and is cost-effective. Experience with the technique and careful planning is needed to minimize any avoidable potential complication. PMID:29214070

  7. Comparing the Overhead of Lock-based and Lock-free Implementations of Priority Queues

    DEFF Research Database (Denmark)

    Passas, Stavros; Karlsson, Sven

    2011-01-01

    . In this paper, we compare a lock-free implementation of a priority queue with a lock-based implementation. We perform experiments with processors of different generations and observe large performance differences for lock-free data structures depending on the processor generation. The lock-free implementation...... performs much better on the most recent processor generation. We investigate this performance trend, using a set of micro-benchmarks and show a significant difference in the overhead of atomic operations between processor generations. The lock-free implementation executes approximately three times as many...

  8. Percutaneous aspiration of hydatid cysts

    International Nuclear Information System (INIS)

    Hernandez, G.; Serrano, R.

    1996-01-01

    A perspective study was carried out to assess the efficacy of a combination of percutaneous aspiration plus oral albendazole to assess its efficacy as an alternative to surgery in the treatment of hydatid cyst. We performed percutaneous aspiration followed by injection of 20% hypertonic saline solution into 16 hydatid cysts in 13 patients. All the patients received oral albendazole (400 mg/12 hours) starting 2 days before and lasting until there weeks after the procedure. There were no anaphylactic reactions during or after the procedure. Follow-up included monthly ultrasound over a period ranging between 10 and 36 months. Three cysts disappeared completely; in 10 cases, the cysts cavity was replaced by a complex ultrasonographic findings, with strong signals similar to those of a pseudotumor. In another case, the aspirate was sterile and its morphology remained unchanged. In two cases, infection of the cyst ensued, requiring surgical treatment. We consider that percutaneous aspiration in combination with albendazole may prove to be a good alternative to surgery for the management of hepatic hydatid disease. (Author) 15 refs

  9. Past, Present, Future Erosion at Locke Island

    Energy Technology Data Exchange (ETDEWEB)

    Bjornstad, Bruce N.

    2006-08-08

    This report describes and documents the erosion that has occurred along the northeast side of Locke Island over the last 10 to 20 years. The principal cause of this erosion is the massive Locke Island landslide complex opposite the Columbia River along the White Bluffs, which constricts the flow of the river and deflects the river's thalweg southward against the island.

  10. An automatic mode-locked system for passively mode-locked fiber laser

    Science.gov (United States)

    Li, Sha; Xu, Jun; Chen, Guoliang; Mei, Li; Yi, Bo

    2013-12-01

    This paper designs and implements one kind of automatic mode-locked system. It can adjust a passively mode-locked fiber laser to keep steady mode-locked states automatically. So the unsteadiness of traditional passively mode-locked fiber laser can be avoided. The system transforms optical signals into electrical pulse signals and sends them into MCU after processing. MCU calculates the frequency of the signals and judges the state of the output based on a quick judgment algorithm. A high-speed comparator is used to check the signals and the comparison voltage can be adjusted to improve the measuring accuracy. Then by controlling two polarization controllers at an angle of 45degrees to each other, MCU extrudes the optical fibers to change the polarization until it gets proper mode-locked output. So the system can continuously monitor the output signal and get it back to mode-locked states quickly and automatically. States of the system can be displayed on the LCD and PC. The parameters of the steady mode-locked states can be stored into an EEPROM so that the system will get into mode-locked states immediately next time. Actual experiments showed that, for a 6.238MHz passively mode-locked fiber lasers, the system can get into steady mode-locked states automatically in less than 90s after starting the system. The expected lock time can be reduced to less than 20s after follow up improvements.

  11. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    Science.gov (United States)

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate

  12. Commonwealth Edison Company pressure locking test report

    Energy Technology Data Exchange (ETDEWEB)

    Bunte, B.D.; Kelly, J.F.

    1996-12-01

    Pressure Locking is a phenomena which can cause the unseating thrust for a gate valve to increase dramatically from its typical static unseating thrust. This can result in the valve actuator having insufficient capability to open the valve. In addition, this can result in valve damage in cases where the actuator capability exceeds the valve structural limits. For these reasons, a proper understanding of the conditions which may cause pressure locking and thermal binding, as well as a methodology for predicting the unseating thrust for a pressure locked or thermally bound valve, are necessary. This report discusses the primary mechanisms which cause pressure locking. These include sudden depressurization of piping adjacent to the valve and pressurization of fluid trapped in the valve bonnet due to heat transfer. This report provides a methodology for calculating the unseating thrust for a valve which is pressure locked. This report provides test data which demonstrates the accuracy of the calculation methodology.

  13. Commonwealth Edison Company pressure locking test report

    International Nuclear Information System (INIS)

    Bunte, B.D.; Kelly, J.F.

    1996-01-01

    Pressure Locking is a phenomena which can cause the unseating thrust for a gate valve to increase dramatically from its typical static unseating thrust. This can result in the valve actuator having insufficient capability to open the valve. In addition, this can result in valve damage in cases where the actuator capability exceeds the valve structural limits. For these reasons, a proper understanding of the conditions which may cause pressure locking and thermal binding, as well as a methodology for predicting the unseating thrust for a pressure locked or thermally bound valve, are necessary. This report discusses the primary mechanisms which cause pressure locking. These include sudden depressurization of piping adjacent to the valve and pressurization of fluid trapped in the valve bonnet due to heat transfer. This report provides a methodology for calculating the unseating thrust for a valve which is pressure locked. This report provides test data which demonstrates the accuracy of the calculation methodology

  14. Neglected locked vertical patellar dislocation

    Science.gov (United States)

    Gupta, Rakesh Kumar; Gupta, Vinay; Sangwan, Sukhbir Singh; Kamboj, Pradeep

    2012-01-01

    Patellar dislocations occurring about the vertical and horizontal axis are rare and irreducible. The neglected patellar dislocation is still rarer. We describe the clinical presentation and management of a case of neglected vertical patellar dislocation in a 6 year-old boy who sustained an external rotational strain with a laterally directed force to his knee. Initially the diagnosis was missed and 2 months later open reduction was done. The increased tension generated by the rotation of the lateral extensor retinaculum kept the patella locked in the lateral gutter even with the knee in full extension. Traumatic patellar dislocation with rotation around a vertical axis has been described earlier, but no such neglected case has been reported to the best of our knowledge. PMID:23162154

  15. Neglected locked vertical patellar dislocation

    Directory of Open Access Journals (Sweden)

    Rakesh Kumar Gupta

    2012-01-01

    Full Text Available Patellar dislocations occurring about the vertical and horizontal axis are rare and irreducible. The neglected patellar dislocation is still rarer. We describe the clinical presentation and management of a case of neglected vertical patellar dislocation in a 6 year-old boy who sustained an external rotational strain with a laterally directed force to his knee. Initially the diagnosis was missed and 2 months later open reduction was done. The increased tension generated by the rotation of the lateral extensor retinaculum kept the patella locked in the lateral gutter even with the knee in full extension. Traumatic patellar dislocation with rotation around a vertical axis has been described earlier, but no such neglected case has been reported to the best of our knowledge.

  16. Unusual Cause of Knee Locking

    Directory of Open Access Journals (Sweden)

    Gazi Huri

    2013-01-01

    Full Text Available We report a case of partial intrasubstance tear of popliteus tendon as an unusual cause of pseudolocking of the knee. A 13-year-old semiprofessional soccer player applied to our clinic with a locked right knee in spite of the therapy applied (cold pack, NSAID, and immobilization in another institution 20 days after the injury. Significant extension loss was observed in his right knee with 30∘–90∘ ROM. Magnetic resonance imaging (MRI and arthroscopy confirmed the intrasubstance tear of popliteus tendon and synovitis. The ruptured part of the tendon was debrided, and the inflammatory tissue around the tendon, which may lead to pseudolocking, was gently removed with a shaver in order to regain the normal ROM. The patient was discharged with full ROM and weight bearing first day after the surgery. To our knowledge, this is the first case demonstrating intrasubstance tear of popliteus tendon causing pseudolocking of the knee.

  17. Development of hold down plate of INGLE fuel assembly

    International Nuclear Information System (INIS)

    Kim, Hyeong Koo; Kim, Kyu Tae

    1996-07-01

    Hold down plate for the INGLE fuel which has been designed for high performance in the standpoints of thermal margin and structural integrity compared to current fuel for YGN 3/4 and UCN 3/4 has been developed and its structural integrity has been verified based on the eh stress analysis. The design feature of the developed hold down plate has not only perfect compatibility with the reactor internals of Korea standard reactor, but also brand-new locking mechanism between upper tie plate and guide tubes. This locking mechanism introduced to the INGLE fuel provides very simple and reliable reconstitutability. In this report, finite element stress analysis with the aid of the ANSYS code as a solver and the MSC/PATRAN code as a pre and post processor were performed to verify structural integrity of the hold down plate considering various load cases which seem to be applied to the hold down plate during its lifetime. Based on the analysis results, the developed hold down plate for INGLE fuel sustains structural integrity under considered load conditions. 3 tabs., 16 figs., 9 refs. (Author)

  18. Obituary: Martha Locke Hazen, 1931-2006

    Science.gov (United States)

    Williams, Thomas R.; Willson, Lee Anne

    2007-12-01

    Longtime Harvard Curator of Astronomical Photographs and AAVSO officer Martha Hazen passed away on 23 December 2006 at Hingham, Massachusetts, after a short illness due to acute myelogenous leukemia. One of four children of Harold Locke and Katherine (neé Salisbury) Hazen, Martha was born in Cambridge, Massachusetts, on 15 July 1931, and raised in the Town of Belmont, near Cambridge, where she lived for most of her life. Her father coined the term "servo-mechanism" while serving as an engineering professor and dean for graduate students at the Massachusetts Institute of Technology. Her mother majored in chemistry at Mount Holyoke College. After receiving an A.B. in astronomy from Mount Holyoke College in 1953, Martha earned a Ph.D. in astronomy in 1958 from the University of Michigan, defending a dissertation on the distribution of intensity in elliptical galaxies in the Virgo cluster. Martha's marriage to William Liller in 1959, and the births of two children, inevitably slowed down her progress in observational astronomy. As a research fellow of the Harvard College Observatory, Martha continued to observe two to three weeks a year in Chile, and to reduce those observations and publish the results for sixteen years. Martha's first publication, at least as far as Astrophysics Data System includes the literature, was with Alice Farnsworth on the 1952 occultations of stars by the Moon, published in the Astronomical Journal (1953). In 1958 she joined L. R. Doherty and D. H. Menzel on a short note about the calculation of line profiles in a stratified atmosphere, her only theory paper. Martha's most cited paper is "The Distribution of Intensity in Elliptical Galaxies of the Virgo Cluster," (ApJ, 132, p.306, 1960). There she acknowledges Allan Sandage for suggesting the problem and providing some of the data. Her second most cited paper is "Photometric histories of QSOs - Two QSOs with large light amplitude," (Liller, M. H. & Liller, W., ApJ (Letters), 199, p. L133-L

  19. No Snowball on Habitable Tidally Locked Planets

    Science.gov (United States)

    Checlair, Jade; Menou, Kristen; Abbot, Dorian S.

    2017-08-01

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO2 outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  20. No Snowball on Habitable Tidally Locked Planets

    Energy Technology Data Exchange (ETDEWEB)

    Checlair, Jade; Abbot, Dorian S. [Department of the Geophysical Sciences, University of Chicago, 5734 South Ellis Avenue, Chicago, IL 60637 (United States); Menou, Kristen, E-mail: jadecheclair@uchicago.edu [Centre for Planetary Sciences, Department of Physical and Environmental Sciences, University of Toronto at Scarborough, Toronto, ON M1C 1A4 (Canada)

    2017-08-20

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO{sub 2} outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  1. No Snowball on Habitable Tidally Locked Planets

    International Nuclear Information System (INIS)

    Checlair, Jade; Abbot, Dorian S.; Menou, Kristen

    2017-01-01

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO 2 outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  2. Percutaneous vertebroplasty (pv): indications, contraindications, and technique

    International Nuclear Information System (INIS)

    Hoffmann, R.T.; Jakobs, T.F.; Wallnoefer, A.; Reiser, M.F.; Helmberger, T.K.

    2003-01-01

    Percutaneous vertebroplasty (pv) is a worldwide increasingly performed interventional therapeutic procedure. This article addresses indications, patient preparation, technical requirements and approach as well as possible complications of percutaneous vertebroplasty. Percutaneous vertebroplasty is a technique consisting in an injection of bone cement into a vertebral body under imaging guidance. This procedure is performed to relief pain and support the mechanical stability in partially collapsed vertebral bodies. In the management of spinal compression fractures secondary to osteoporosis, myeloma, osteolytic metastases and aggressive hemangiomas, percutaneous vertebroplasty yields analgesic effect, and provides additional fortification in weakened segments of the vertebral column. Contraindications include major bleeding disorders, radicular pain and pain caused by compression of the myelon. Percutaneous vertebroplasty results in prompt pain relief and rapid rehabilitation. In experienced hands, using correct technique, pv is a safe and effective procedure for treating pain, caused either by osteoporotic or malignant vertebral compression fractures. (orig.) [de

  3. 408-fs SESAM mode locked Cr:ZnSe laser

    Science.gov (United States)

    Bu, Xiangbao; Shi, Yuhang; Xu, Jia; Li, Huijuan; Wang, Pu

    2018-01-01

    We report self-starting femtosecond operation of a 127-MHz SESAM mode locked Cr:ZnSe laser around 2420 nm. A thulium doped double clad fiber laser at 1908 nm was used as the pumping source. In the normal dispersion regime, stable pulse pairs with constant phase differences in the multipulse regime were observed. The maximum output power was 342 mW with respect to incident pump power of 4.8 W and the corresponding slope efficiency was 10.4%. By inserting a piece of sapphire plate, dispersion compensation was achieved and the intra-cavity dispersion was moved to the anomalous regime. A maximum output power of 403 mW was obtained and the corresponding slope efficiency was 12.2%. Pulse width was measured to be 408 fs by a collinear autocorrelator using two-photon absorption in an InGaAs photodiode. The laser spectrum in multipulse operation showed a clear periodic modulation.

  4. Percutaneous biliary drainage and stenting

    International Nuclear Information System (INIS)

    Totev, M.

    2012-01-01

    Full text: Percutaneous transhepatic cholangiography (PTC) is an X-ray or US guided procedure that involves the injection of a contrast material directly into the bile ducts inside the liver to produce pictures of them. If a blockage or narrowing is found, additional procedures may be performed: 1. insertion of a catheter to drain excess bile out of the body or both - internal and external; 2. plastic endoprothesis placement; 3. self-expandable metal stents placement to help open bile ducts or to bypass an obstruction and allow fluids to drain. Current percutaneous biliary interventions include percutaneous transhepatic cholangiography (PTC) and biliary drainage to manage benign and malignant obstructions. Internal biliary stents are either plastic or metallic, and various types of each kind are available. Internal biliary stents have several advantages. An external tube can be uncomfortable and have a psychological disadvantage. An internal stent prevents the problems related to external catheters, for example, pericatheter leakage of bile and the need for daily flushing. The disadvantages include having to perform endoscopic retrograde cholangiopancreatography (ERCP) or new PTC procedures to obtain access in case of stent obstruction. Better patency rates are reported with metallic than with plastic stents in cases of malignant obstruction, though no effect on survival is noted. Plastic internal stents are the cheapest but reportedly prone to migration. Metallic stents are generally not used in the treatment of benign disease because studies have shown poor long-term patency rates. Limited applications may include the treatment of patients who are poor surgical candidates or of those in whom surgical treatment fails. Most postoperative strictures are treated surgically, though endoscopic and (less commonly) percutaneous placement of nonmetallic stents has increasingly been used in the past few years. Now there are some reports about use of biodegradable biliary

  5. [The percutaneous absorption of diclofenac].

    Science.gov (United States)

    Riess, W; Schmid, K; Botta, L; Kobayashi, K; Moppert, J; Schneider, W; Sioufi, A; Strusberg, A; Tomasi, M

    1986-07-01

    The percutaneous absorption of diclofenac diethylammonium 1.16% (w/w) in a combination of emulsion cream and gel (Voltaren Emulgel) and of diclofenac sodium 1% (w/w) in a cream formulation (Voltaren cream) was investigated in guinea-pig, rabbit and man. The percutaneous absorption of diclofenac sodium in guinea-pig was 3 to 6% of the dose when the cream formulation in doses of 320, 100 or 40 mg was applied on 10 cm2 of occluded skin and left in place for 6 h. The transdermal delivery of 14C-labelled diclofenac yielded plateau plasma concentrations of radiotracer from 1.5 h after application until removal of the residual cream. Subsequently the steady state drug depots in the skin and muscle tissue were depleted promptly. During daily administration the steady state levels in the muscle tissue in proximity to the application site were about 3 times higher than in distant muscle tissue. By topical application on knee joints of rabbits diclofenac penetrated into the patellar ligament, the adipose corpus and the synovial fluid. In man the percutaneous absorption was 6% of the dose when the Emulgel formulation was spread by 5 mg/cm2 and left for 12 h on non-occluded skin. The pattern of metabolites of diclofenac in human urine was the same after topical and oral administration. In man, upon daily topical administration of 3 times 2.5 g cream formulation (10 mg/cm2) the diclofenac steady state plasma levels were 20 to 40 nmol/l.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Correlations between locked modes and impurity influxes

    Energy Technology Data Exchange (ETDEWEB)

    Fishpool, G M [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Lawson, K D [UKAEA Culham Lab., Abingdon (United Kingdom)

    1994-07-01

    An analysis of pulses that were disturbed by medium Z impurity influxes (Cl, Cr, Fe and Ni) recorded during the 91/92 JET operations, has demonstrated that such influxes can result in MHD modes which subsequently ``lock``. A correlation is found between the power radiated by the influx and the time difference between the start of the influx and the beginning of the locked mode. The growth in the amplitude of the locked mode itself can lead to further impurity influxes. A correlation is noted between intense influxes (superior to 10 MW) and the mode ``unlocking``. (authors). 4 refs., 4 figs.

  7. The Advanced Thread-Locking Mechanism

    Science.gov (United States)

    Weiss, Wolfgang

    2005-12-01

    Locking of threaded members is accomplished by a wide variety of engineering solutions. Generally, in terms of separate locking devices or by built-in locking features such as friction generating means.In regard of space flight vehicles, threaded joints are subject to severe vibration loads during launch, maneuvering, and reentry. This requires fastening systems which are capable to join structural members and attach accessories or equipment in a secure manner. However, manned spacecraft and especially payload components will be subject to installation activity during orbital or interstellar flight maintenance, repair, or mission modification. This, in turn, requires fast separation and engaging of the concerned fasteners, yet providing performance characteristics for high reliable and safe joints.The further described Advanced Thread Locking Mechanism (ATLM) has been developed to combine the merits of both, safe joining technique and a fast installation process. The ATLM uses a freewheel which is securely installed in one part of the threaded member and releasable coupled with the engaged counterpart. While screwing the threaded members together, once coupled, the freewheel will allow free mating of the threaded members including torquing to the desired value. The moment, the pair of threaded fasteners is forced to unscrew (by intended or unintended occurrence of torque in the undoing direction) the freewheel does lock instantly. Disengaging the coupling between the members of the threaded joint takes a separate release action.Owing to the nature of the ATLM, there are a number of design variants ready for implementation.Threaded fasteners in ATLM design are highly recommended for mechanical joints subject to fastening and unfastening during Extra Vehicular Activity (EVA) in course of space flight operations. This is justified through:1. Threaded members mate free running, thus, torque values preset at the wrenching tool are not influenced by varying prevailing

  8. Recent Advances in Percutaneous Nephrolithotomy

    Directory of Open Access Journals (Sweden)

    Erem Kaan Basok

    2014-05-01

    Full Text Available The continuous innovations in technology, instrumentations, and techniques allow urologists to perform percutaneous nephrolithotomy (PCNL with increasing efficacy. Although recent advances have facilitated the procedure, some steps are still challenging. A thorough review of the recent urologic literature was performed to identify these improvements in PCNL technique. The newer developments mainly focused on multimodal imaging techniques, miniaturisation of instruments, tracking and navigation systems during access to the stone, and robotic systems. Further studies are necessary to better define the benefits of these new fruitful developments which remain an active research field.

  9. Clinical review: Percutaneous dilatational tracheostomy

    Science.gov (United States)

    Al-Ansari, Mariam A; Hijazi, Mohammed H

    2006-01-01

    As the number of critically ill patients requiring tracheotomy for prolonged ventilation has increased, the demand for a procedural alternative to the surgical tracheostomy (ST) has also emerged. Since its introduction, percutaneous dilatational tracheostomies (PDT) have gained increasing popularity. The most commonly cited advantages are the ease of the familiar technique and the ability to perform the procedure at the bedside. It is now considered a viable alternative to (ST) in the intensive care unit. Evaluation of PDT procedural modifications will require evaluation in randomized clinical trials. Regardless of the PDT technique, meticulous preoperative and postoperative management are necessary to maintain the excellent safety record of PDT. PMID:16356203

  10. Percutaneous drainage of lung abscesses

    International Nuclear Information System (INIS)

    van Sonnenberg, E.; D'Agostino, H.; Casola, G.; Vatney, R.R.; Wittich, G.R.; Harker, C.

    1989-01-01

    The authors performed percutaneous drainage of lung abscesses in 12 patients. Indications for drainage were septicemia and persistence or worsening of radiographic findings. These lung abscesses were refractory to intravenous antibiotics and to bronchial toilet. Etiology of the abscesses included pneumonia (most frequently), trauma, postoperative development, infected necrotic neoplasm, and infected sequestration. Guidelines for drainage included passage of the catheter through contiguously abnormal lung and pleura, inability of the patient to cough, and/or bronchial obstruction precluding bronchial drainage. Cure was achieved in 11 of 12 patients. Catheters were removed on an average of 16 days after insertion. Antibiotics were administered an average of 18 days before drainage. No major complications occurred

  11. Percutaneous placement of ureteral stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Hyup; Park, Jae Hyung; Han, Joon Koo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Antegrade placement of ureteral stents has successfully achieved in 41 of 46 ureters. When it was difficult to advance ureteral stents through the lesion, it was facilitated by retrograde guide-wire snare technique through urethra. Complications associated with the procedure were non-function of ureteral stent by occlusion, upward migration,and spontaneous fracture of ureteral stent. These complications were managed by percutaneous nephrostomy and removal of ureteral stents by guide-wire snare technique and insertion of a new ureteral stent. While blood cell in urine was markedly increased in about 50% of patients following the procedure.

  12. Dynamic plate osteosynthesis for fracture stabilization: how to do it

    Directory of Open Access Journals (Sweden)

    Juerg Sonderegger

    2010-01-01

    Full Text Available Plate osteosynthesis is one treatment option for the stabilization of long bones. It is widely accepted to achieve bone healing with a dynamic and biological fixation where the perfusion of the bone is left intact and micromotion at the fracture gap is allowed. The indications for a dynamic plate osteosynthesis include distal tibial and femoral fractures, some midshaft fractures, and adolescent tibial and femoral fractures with not fully closed growth plates. Although many lower limb shaft fractures are managed successfully with intramedullary nails, there are some important advantages of open-reduction-and-plate fixation: the risk of malalignment, anterior knee pain, or nonunion seems to be lower. The surgeon performing a plate osteosynthesis has the possibility to influence fixation strength and micromotion at the fracture gap. Long plates and oblique screws at the plate ends increase fixation strength. However, the number of screws does influence stiffness and stability. Lag screws and screws close to the fracture site reduce micromotion dramatically. Dynamic plate osteosynthesis can be achieved by applying some simple rules: long plates with only a few screws should be used. Oblique screws at the plate ends increase the pullout strength. Two or three holes at the fracture site should be omitted. Lag screws, especially through the plate, must be avoided whenever possible. Compression is not required. Locking plates are recommended only in fractures close to the joint. When respecting these basic concepts, dynamic plate osteosynthesis is a safe procedure with a high healing and a low complication rate. 

  13. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  14. Optical double-locked semiconductor lasers

    Science.gov (United States)

    AlMulla, Mohammad

    2018-06-01

    Self-sustained period-one (P1) nonlinear dynamics of a semiconductor laser are investigated when both optical injection and modulation are applied for stable microwave frequency generation. Locking the P1 oscillation through modulation on the bias current, injection strength, or detuning frequency stabilizes the P1 oscillation. Through the phase noise variance, the different modulation types are compared. It is demonstrated that locking the P1 oscillation through optical modulation on the output of the master laser outperforms bias-current modulation of the slave laser. Master laser modulation shows wider P1-oscillation locking range and lower phase noise variance. The locking characteristics of the P1 oscillation also depend on the operating conditions of the optical injection system

  15. Improving generalized inverted index lock wait times

    Science.gov (United States)

    Borodin, A.; Mirvoda, S.; Porshnev, S.; Ponomareva, O.

    2018-01-01

    Concurrent operations on tree like data structures is a cornerstone of any database system. Concurrent operations intended for improving read\\write performance and usually implemented via some way of locking. Deadlock-free methods of concurrency control are known as tree locking protocols. These protocols provide basic operations(verbs) and algorithm (ways of operation invocations) for applying it to any tree-like data structure. These algorithms operate on data, managed by storage engine which are very different among RDBMS implementations. In this paper, we discuss tree locking protocol implementation for General inverted index (Gin) applied to multiversion concurrency control (MVCC) storage engine inside PostgreSQL RDBMS. After that we introduce improvements to locking protocol and provide usage statistics about evaluation of our improvement in very high load environment in one of the world’s largest IT company.

  16. Automatic NMR field-frequency lock-pulsed phase locked loop approach.

    Science.gov (United States)

    Kan, S; Gonord, P; Fan, M; Sauzade, M; Courtieu, J

    1978-06-01

    A self-contained deuterium frequency-field lock scheme for a high-resolution NMR spectrometer is described. It is based on phase locked loop techniques in which the free induction decay signal behaves as a voltage-controlled oscillator. By pulsing the spins at an offset frequency of a few hundred hertz and using a digital phase-frequency discriminator this method not only eliminates the usual phase, rf power, offset adjustments needed in conventional lock systems but also possesses the automatic pull-in characteristics that dispense with the use of field sweeps to locate the NMR line prior to closure of the lock loop.

  17. Interband optical pulse injection locking of quantum dot mode-locked semiconductor laser.

    Science.gov (United States)

    Kim, Jimyung; Delfyett, Peter J

    2008-07-21

    We experimentally demonstrate optical clock recovery from quantum dot mode-locked semiconductor lasers by interband optical pulse injection locking. The passively mode-locked slave laser oscillating on the ground state or the first excited state transition is locked through the injection of optical pulses generated via the opposite transition bands, i.e. the first excited state or the ground state transition from the hybridly mode-locked master laser, respectively. When an optical pulse train generated via the first excited state from the master laser is injected to the slave laser oscillating via ground state, the slave laser shows an asymmetric locking bandwidth around the nominal repetition rate of the slave laser. In the reverse injection case of, i.e. the ground state (master laser) to the first excited state (slave laser), the slave laser does not lock even though both lasers oscillate at the same cavity frequency. In this case, the slave laser only locks to higher injection rates as compared to its own nominal repetition rate, and also shows a large locking bandwidth of 6.7 MHz.

  18. Radiation shielding plate

    International Nuclear Information System (INIS)

    Kobayashi, Torakichi; Sugawara, Takeo.

    1983-01-01

    Purpose: To reduce the weight and stabilize the configuration of a radiation shielding plate which is used in close contact with an object to be irradiated with radiation rays. Constitution: The radiation shielding plate comprises a substrate made of lead glass and a metallic lead coating on the surface of the substrate by means of plating, vapor deposition or the like. Apertures for permeating radiation rays are formed to the radiation shielding plate. Since the shielding plate is based on a lead glass plate, a sufficient mechanical strength can be obtained with a thinner structure as compared with the conventional plate made of metallic lead. Accordingly, if the shielding plate is disposed on a soft object to be irradiated with radiation rays, the object and the plate itself less deform to obtain a radiation irradiation pattern with distinct edges. (Moriyama, K.)

  19. QPSK regeneration without active phase-locking

    DEFF Research Database (Denmark)

    Kjøller, Niels-Kristian; Da Ros, Francesco; Røge, Kasper Meldgaard

    2016-01-01

    QPSK regeneration without active phase stabilization is investigated in numerical simulations. We propose an improved scheme for phase-locking free QPSK regeneration showing significant improvements in the error vector magnitude of the signal.......QPSK regeneration without active phase stabilization is investigated in numerical simulations. We propose an improved scheme for phase-locking free QPSK regeneration showing significant improvements in the error vector magnitude of the signal....

  20. Percutaneous transcatheter sclerotherapy of oophoritic cysts

    International Nuclear Information System (INIS)

    Huang Youhua; Xu Qiang; Sun Jun; Shen Tao; Shi Hongjian; Tang Qingfang; Chen Qiying; Zhou Mingxia; Li Hongyao

    2005-01-01

    Objective: To evaluate the clinical value of percutaneous transcatheter sclerotherapy in oophoritic cysts. Methods: Seventy six oophoritic cysts incluoling 48 simple and 28 chocolate cysts of 64 patients were treated with percutaneous transcatheter sclerotherapy under CT guidance. 4F multisideholes pigtail catheter was introduced into cyst using absolute alcohol as sclerosing agents. Results: The successful rate of percutaneous oophoritc cyst puncture was 100% in all 64 patients. Among them 58 were cured (90.6%), 6 improved significantly (9.4%). The total effective rate reached 100% with no serious complications. Conclusions: Catheterization sclerotherapy for oophoritic cyst is a simple, complete, safe and effective method. (authors)

  1. Create Your Plate

    Medline Plus

    Full Text Available ... foods you want, but changes the portion sizes so you are getting larger portions of non-starchy ... plate. Then on one side, cut it again so you will have three sections on your plate. ...

  2. Create Your Plate

    Medline Plus

    Full Text Available ... of the differences in types of vegetables. When creating your plate at home, remember that half of ... effective for both managing diabetes and losing weight. Creating your plate lets you still choose the foods ...

  3. Create Your Plate

    Medline Plus

    Full Text Available ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ... Plate Create Your Plate is a simple and effective way to manage your blood glucose levels and ...

  4. Create Your Plate

    Medline Plus

    Full Text Available ... Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with ... Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy ...

  5. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ... Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook ...

  6. Computation of the lock-in ranges of phase-locked loops with PI filter

    OpenAIRE

    Aleksandrov, Konstantin D.; Kuznetsov, Nikolay; Leonov, Gennady A.; Neittaanmäki, Pekka; Yuldashev, Marat V.; Yuldashev, Renat V.

    2016-01-01

    In the present work the lock-in range of PLL-based circuits with proportionallyintegrating filter and sinusoidal phase-detector characteristics are studied. Considered circuits have sinusoidal phase detector characteristics. Analytical approach based on the methods of phase plane analysis is applied to estimate the lock-in ranges of the circuits under consideration. Obtained analytical results are compared with simulation results.

  7. Multi-operational tuneable Q-switched mode-locking Er fibre laser

    Science.gov (United States)

    Qamar, F. Z.

    2018-01-01

    A wavelength-spacing tuneable, Q-switched mode-locking (QML) erbium-doped fibre laser based on non-linear polarization rotation controlled by four waveplates and a cube polarizer is proposed. A mode-locked pulse train using two quarter-wave plates and a half-wave plate (HWP) is obtained first, and then an extra HWP is inserted into the cavity to produce different operation regimes. The evolutions of temporal and spectral dynamics with different orientation angles of the extra HWP are investigated. A fully modulated stable QML pulse train is observed experimentally. This is, to the author’s best knowledge, the first experimental work reporting QML operation without adding an extra saturable absorber inside the laser cavity. Multi-wavelength pulse laser operation, multi-pulse train continuous-wave mode-locking operation and pulse-splitting operations are also reported at certain HWP angles. The observed operational dynamics are interpreted as a mutual interaction of dispersion, non-linear effect and insertion loss. This work provides a new mechanism for fabricating cheap tuneable multi-wavelength lasers with QML pulses.

  8. DLS 5.0--the biomechanical effects of dynamic locking screws.

    Directory of Open Access Journals (Sweden)

    Stefan Döbele

    Full Text Available INTRODUCTION: Indirect reduction of dia-/metaphyseal fractures with minimally invasive implant application bridges the fracture zone in order to protect the soft-tissue and blood supply. The goal of this fixation strategy is to allow stable motion at the fracture site to achieve indirect bone healing with callus formation. However, concerns have arisen that the high axial stiffness and eccentric position of locked plating constructs may suppress interfragmentary motion and callus formation, particularly under the plate. The reason for this is an asymmetric fracture movement. The biological need for sufficient callus formation and secondary bone healing is three-dimensional micro movement in the fracture zone. The DLS was designed to allow for increased fracture site motion. The purpose of the current study was to determine the biomechanical effect of the DLS_5.0. METHODS: Twelve surrogate bone models were used for analyzing the characteristics of the DLS_5.0. The axial stiffness and the interfragmentary motion of locked plating constructs with DLS were compared to conventional constructs with Locking Head Screws (LS_5.0. A quasi-static axial load of 0 to 2.5 kN was applied. Relative motion was measured. RESULTS: The dynamic system showed a biphasic axial stiffness distribution and provided a significant reduction of the initial axial stiffness of 74.4%. Additionally, the interfragmentary motion at the near cortex increased significantly from 0.033 mm to 0.210 mm (at 200N. CONCLUSIONS: The DLS may ultimately be an improvement over the angular stable plate osteosynthesis. The advantages of the angular stability are not only preserved but even supplemented by a dynamic element which leads to homogenous fracture movement and to a potentially uniform callus distribution.

  9. Assessment of Optimum Value for Dip Angle and Locking Rate Parameters in Makran Subduction Zone

    Science.gov (United States)

    Safari, A.; Abolghasem, A. M.; Abedini, N.; Mousavi, Z.

    2017-09-01

    Makran subduction zone is one of the convergent areas that have been studied by spatial geodesy. Makran zone is located in the South Eastern of Iran and South of Pakistan forming the part of Eurasian-Arabian plate's border where oceanic crust in the Arabian plate (or in Oman Sea) subducts under the Eurasian plate ( Farhoudi and Karig, 1977). Due to lack of historical and modern tools in the area, a sampling of sparse measurements of the permanent GPS stations and temporary stations (campaign) has been conducted in the past decade. Makran subduction zone from different perspectives has unusual behaviour: For example, the Eastern and Western parts of the region have very different seismicity and also dip angle of subducted plate is in about 2 to 8 degrees that this value due to the dip angle in other subduction zone is very low. In this study, we want to find the best possible value for parameters that differs Makran subduction zone from other subduction zones. Rigid block modelling method was used to determine these parameters. From the velocity vectors calculated from GPS observations in this area, block model is formed. These observations are obtained from GPS stations that a number of them are located in South Eastern Iran and South Western Pakistan and a station located in North Eastern Oman. According to previous studies in which the locking depth of Makran subduction zone is 38km (Frohling, 2016), in the preparation of this model, parameter value of at least 38 km is considered. With this function, the amount of 2 degree value is the best value for dip angle but for the locking rate there is not any specified amount. Because the proposed model is not sensitive to this parameter. So we can not expect big earthquakes in West of Makran or a low seismicity activity in there but the proposed model definitely shows the Makran subduction layer is locked.

  10. An update on percutaneous nephrolithotomy

    DEFF Research Database (Denmark)

    Tefekli, A; Cordeiro, E; de la Rosette, J J M C H

    2013-01-01

    Since its introduction in late 1970's, percutaneous nephrolithotomy (PNL) has undergone an evolution in both equipment and technique. This evolution still continues today in the era of minimally invasive treatment options, and is evidenced by the numerous publications. PNL is generally advantageous...... in the management of large renal stones (>1.5-2 cm) with high stone-free rates and considerable complication rates. However this technique is especially competing with retrograde intrarenal surgery and laparoscopic techniques. Therefore the CROES Global PNL Study Group prospectively collected data of over 5800...... patients managed with PNL worldwide and analyzed the data in detail, producing more than 25 scientific papers. And this update focuses on the lessons learned from the CROES PCNL Global Study....

  11. The percutaneous nephrolithotomy global study

    DEFF Research Database (Denmark)

    Labate, Gaston; Modi, Pranjal; Timoney, Anthony

    2011-01-01

    PCNL Global Study collected prospective data for consecutive patients who were treated with PCNL at centers around the world for 1 year. Complications were evaluated by the modified Clavien classification system. RESULTS: Of 5724 patients with Clavien scores, 1175 (20.5%) patients experienced one......PURPOSE: This study evaluated postoperative complications of percutaneous nephrolithotomy (PCNL) and the influence of selected factors on the risk of complications using the Clinical Research Office of the Endourological Society (CROES) PCNL Global Study database. PATIENTS AND METHODS: The CROES...... grade I. Two patients died in the postoperative period. The largest absolute increases in mean Clavien score were associated with American Society of Anesthesiologists (ASA) physical status classification IV (0.75) or III (0.34), anticoagulant medication use (0.29), positive microbiologic culture from...

  12. Left main percutaneous coronary intervention.

    Science.gov (United States)

    Teirstein, Paul S; Price, Matthew J

    2012-10-23

    The introduction of drug-eluting stents and advances in catheter techniques have led to increasing acceptance of percutaneous coronary intervention (PCI) as a viable alternative to coronary artery bypass graft (CABG) for unprotected left main disease. Current guidelines state that it is reasonable to consider unprotected left main PCI in patients with low to intermediate anatomic complexity who are at increased surgical risk. Data from randomized trials involving patients who are candidates for either treatment strategy provide novel insight into the relative safety and efficacy of PCI for this lesion subset. Herein, we review the current data comparing PCI with CABG for left main disease, summarize recent guideline recommendations, and provide an update on technical considerations that may optimize clinical outcomes in left main PCI. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Percutaneous transluminal angioplasty in arteriosclerosis

    International Nuclear Information System (INIS)

    Chung, Soo Young; Cha, In Ho

    1984-01-01

    Percutaneous transluminal angioplasty (PTA) is a non-operative therapeutic procedure to the dilation of stenosis or to the recanalization of occlusion in atherosclerotic arteries using of dilatation catheters. PTA was performed 37 times in 34 patients with arteriosclerotic for 1 year and 4 months from March, 1982 to June, 1983 at department of radiology, Klinikum Barmen/west Germany. The results were as follows; 1. The male to female ratio was 2 : 1 and peak age range was from 61 to 70. 2. The most common indication was clinical stage II b with 19 cases (51.3%). 3. PTA was performed most commonly in superficial femora artery in 25 cases (67.5%). 4. Acute major complication occurred in 2 cases (5.4%). PTA is a alternative or complementary therapeutic procedure to vascular surgery.

  14. Percutaneous management of urolithiasis during pregnancy.

    Science.gov (United States)

    Kavoussi, L R; Albala, D M; Basler, J W; Apte, S; Clayman, R V

    1992-09-01

    A total of 6 pregnant women with obstructing urinary calculi was managed by percutaneous nephrostomy drainage placed under ultrasound guidance with the patient under local anesthesia. All patients initially had relief of acute obstruction. However, occlusion of the percutaneous nephrostomy tubes with debris necessitated tube changes in 5 of 6 patients. In 2 patients recurrent nephrostomy tube obstruction, fever and pain led to percutaneous stone removal during pregnancy. In the remaining 4 patients the nephrostomy tubes were left indwelling through delivery. During the postpartum period 3 patients successfully underwent ureteroscopic stone extraction and 1 passed the stone spontaneously. Bacteriuria developed in each patient despite the use of preventive antibiotics. All 6 women had uncomplicated vaginal deliveries of healthy newborns and are currently asymptomatic with no evidence of obstruction. Percutaneous drainage of an acutely obstructed kidney in a pregnant woman is an effective temporizing alternative to ureteral stent placement until definitive treatment can be performed.

  15. Successful percutaneous management of Lutembacher syndrome

    Directory of Open Access Journals (Sweden)

    Sandeep Goel

    2014-05-01

    Conclusion: Percutaneous management of the Lutembacher syndrome (PTMC and ASD device closure is an effective and low risk procedure and avoids considerable morbidity and mental trauma for the patients.

  16. Conservative management of colonic injury during percutaneous ...

    African Journals Online (AJOL)

    M. Elghoneimy

    2016-02-22

    Feb 22, 2016 ... Patients' records were searched for the occurrence of colonic injury. Records were ... tion to opacify the system and the percutaneous renal access was .... identify the presence of a retrorenal colon, yet the rarity of such a.

  17. Percutaneous treatment of liver hydatid cysts

    Energy Technology Data Exchange (ETDEWEB)

    Akhan, Okan; Oezmen, Mustafa N

    1999-10-01

    Hydatic disease caused by Echinococcus granulosus is an endemic disease and an important public health problem in some countries of the world. The results of surgical treatment are associated with a high rate of mortality, morbidity, postoperative recurrence and a long period of hospital stay and the medical treatment results are still controversial. Although the percutaneous aspiration and treatment of liver hydatid cysts were considered to be contraindicated due to risks of anaphylactic shock and dissemination of clear-crystal fluid into the abdomen, several reports of successful percutaneous treatment of liver hydatid cysts have been published in the literature. Today, percutaneous treatment of liver hydatid cysts is the most effective and reliable treatment procedure in the selected cases. In this review, indications, contraindications, method and techniques, healing criteria, complications, results and importance of the percutaneous treatment of liver hydatid cysts are discussed.

  18. Percutaneous treatment of liver hydatid cysts

    International Nuclear Information System (INIS)

    Akhan, Okan; Oezmen, Mustafa N.

    1999-01-01

    Hydatic disease caused by Echinococcus granulosus is an endemic disease and an important public health problem in some countries of the world. The results of surgical treatment are associated with a high rate of mortality, morbidity, postoperative recurrence and a long period of hospital stay and the medical treatment results are still controversial. Although the percutaneous aspiration and treatment of liver hydatid cysts were considered to be contraindicated due to risks of anaphylactic shock and dissemination of clear-crystal fluid into the abdomen, several reports of successful percutaneous treatment of liver hydatid cysts have been published in the literature. Today, percutaneous treatment of liver hydatid cysts is the most effective and reliable treatment procedure in the selected cases. In this review, indications, contraindications, method and techniques, healing criteria, complications, results and importance of the percutaneous treatment of liver hydatid cysts are discussed

  19. Percutaneous penetration studies for risk assessment

    DEFF Research Database (Denmark)

    Sartorelli, Vittorio; Andersen, Helle Raun; Angerer, Jürgen

    2000-01-01

    . In order to predict the systemic risk of dermally absorbed chemicals and to enable agencies to set safety standards, data is needed on the rates of percutaneous penetration of important chemicals. Standardization of in vitro tests and comparison of their results with the in vivo data could produce...... internationally accepted penetration rates and/or absorption percentages very useful for regulatory toxicology. The work of the Percutaneous Penetration Subgroup of EC Dermal Exposure Network has been focussed on the standardization and validation of in vitro experiments, necessary to obtain internationally...... accepted penetration rates for regulatory purposes. The members of the Subgroup analyzed the guidelines on percutaneous penetration in vitro studies presented by various organizations and suggested a standardization of in vitro models for percutaneous penetration taking into account their individual...

  20. Reported incidences and factors associated with percutaneous ...

    African Journals Online (AJOL)

    Microsoft Office User

    precautions, training and reduction of long working hours are necessary in order to reduce infections from .... -4-. Incidences of percutaneous injuries and mucocutaneous blood exposure ... than 40 hours per week (14.9 %) (p= 0.001).

  1. Bivalirudin in percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Sam J Lehman

    2006-12-01

    Full Text Available Sam J Lehman, Derek P ChewDepartment of Medicine, Flinders University, South Australia, AustraliaAbstract: Bivalirudin is a member of the direct thrombin inhibitor group of anticoagulants. It has been evaluated as an alternative to unfractionated and low-molecular-weight heparins in the settings of percutaneous coronary intervention (PCI and acute coronary syndrome (ACS. Results of clinical trials to date suggest bivalirudin is a viable alternative to the use of a heparin combined with a glycoprotein (GP IIb/IIIa inhibitor in these settings. Thrombin has a central role in coagulation and platelet activation in ACS and during PCI. Its direct inhibition is an attractive target for therapy in these settings. Bivalirudin is a 20 amino acid polypeptide hirudin analog. It displays bivalent and reversible binding to the thrombin molecule, inhibiting its action. Direct inhibition of thrombin with bivalirudin has theoretical pharmacokinetic and pharmacodynamic advantages over the indirect anticoagulants. A reduction in rates of bleeding without loss of anti-thrombotic efficacy has been a consistent finding across multiple clinical trials. There may be economic benefits to the use of bivalirudin if it permits a lower rate of use of the GP IIb/IIIa inhibitors. This article reviews the pharmacology of bivalirudin and clinical trial evidence to date. There are now data from multiple clinical trials and meta-analyses in the setting of ACS and PCI. Early results from the acute catheterization and urgent intervention strategy (ACUITY trial are discussed. Keywords: bivalirudin, direct thrombin inhibitor, acute coronary syndrome, percutaneous coronary intervention

  2. Percutaneous transluminal angioplasty of the carotid artery

    International Nuclear Information System (INIS)

    Numaguchi, Y.; Tulane Univ., New Orleans, LA; Puyau, F.A.; Provenza, L.J.; Richardson, D.E.

    1984-01-01

    The successful dilatation of postsurgical concentric stenosis of an internal carotid artery using percutaneous transluminal angioplasty (PTA) is reported here. Only one such case has been previously documented. Review of the literature disclosed 16 patients who received transluminal angioplasty for stenosis of carotid arteries by percutaneous or open arteriotomy techniques. The authors feel that PTA may be the treatment of choice for postoperative concentric stenosis of a short segment of the carotid artery as opposed to surgical repair. (orig.)

  3. Percutaneous drainage treatment of primary liver abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Berger, H.; Pratschke, E.; Berr, F.; Fink, U.

    1989-02-01

    28 primary liver abscesses, including 9 amoebic abscesses, in 24 patients were drained percutaneously. Indication for drainage in amoebic abscesses was imminent rupture and clinical symptoms as pleural effusion, lung atelectasis and pain. 95% of the primary abscesses were cured by percutaneous drainage and systemic antibiotic treatment. There was one recurrence of abscess, which was managed surgically. Reasons for drainage failure were: tumour necrosis and tumour perforation with secondary liver abscess.

  4. Percutaneous drainage treatment of primary liver abscesses

    International Nuclear Information System (INIS)

    Berger, H.; Pratschke, E.; Berr, F.; Fink, U.; Klinikum Grosshadern, Muenchen; Klinikum Grosshadern, Muenchen

    1989-01-01

    28 primary liver abscesses, including 9 amoebic abscesses, in 24 patients were drained percutaneously. Indication for drainage in amoebic abscesses was imminent rupture and clinical symptoms as pleural effusion, lung atelectasis and pain. 95% of the primary abscesses were cured by percutaneous drainage and systemic antibiotic treatment. There was one recurrence of abscess, which was managed surgically. Reasons for drainage failure were: tumour necrosis and tumour perforation with secondary liver abscess. (orig.) [de

  5. Infective endocarditis following percutaneous pulmonary valve replacement

    DEFF Research Database (Denmark)

    Cheung, Gary; Vejlstrup, Niels; Ihlemann, Nikolaj

    2013-01-01

    Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult.......Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult....

  6. Pancreatic cancer seeding of percutaneous needle tract

    Directory of Open Access Journals (Sweden)

    Qiao Zhou, MD

    2017-03-01

    Full Text Available A 65-year old African-American female presents with biliary ductal dilatation due to an obstructive pancreatic head mass. Percutaneous transhepatic cholangiogram performed and biliary drainage catheter placement for decompression of the biliary system. The patient had a Whipple procedure performed several months later. On follow up CT imaging, there was interval development and enlargement of a subcutaneous lesion by the right oblique muscles. Biopsy of this lesion revealed pancreatic adenocarcinoma from percutaneous seeding of the transhepatic needle tract.

  7. Pulmonary Cement Embolism following Percutaneous Vertebroplasty

    Directory of Open Access Journals (Sweden)

    Ümran Toru

    2014-01-01

    Full Text Available Percutaneous vertebroplasty is a minimal invasive procedure that is applied for the treatment of osteoporotic vertebral fractures. During vertebroplasty, the leakage of bone cement outside the vertebral body leads to pulmonary cement embolism, which is a serious complication of this procedure. Here we report a 48-year-old man who was admitted to our hospital with dyspnea after percutaneous vertebroplasty and diagnosed as pulmonary cement embolism.

  8. Percutaneous catheter drainage of intrapulmonary fluid collection

    International Nuclear Information System (INIS)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H.

    1994-01-01

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment

  9. Percutaneous catheter drainage of intrapulmonary fluid collection

    Energy Technology Data Exchange (ETDEWEB)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H. [Gyeongsang National University Hospital, Chinju (Korea, Republic of)

    1994-01-15

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment.

  10. Universal spin-momentum locked optical forces

    Energy Technology Data Exchange (ETDEWEB)

    Kalhor, Farid [Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Thundat, Thomas [Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Jacob, Zubin, E-mail: zjacob@purdue.edu [Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Birck Nanotechnology Center, Department of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47906 (United States)

    2016-02-08

    Evanescent electromagnetic waves possess spin-momentum locking, where the direction of propagation (momentum) is locked to the inherent polarization of the wave (transverse spin). We study the optical forces arising from this universal phenomenon and show that the fundamental origin of recently reported non-trivial optical chiral forces is spin-momentum locking. For evanescent waves, we show that the direction of energy flow, the direction of decay, and the direction of spin follow a right hand rule for three different cases of total internal reflection, surface plasmon polaritons, and HE{sub 11} mode of an optical fiber. Furthermore, we explain how the recently reported phenomena of lateral optical force on chiral and achiral particles are caused by the transverse spin of the evanescent field and the spin-momentum locking phenomenon. Finally, we propose an experiment to identify the unique lateral forces arising from the transverse spin in the optical fiber and point to fundamental differences of the spin density from the well-known orbital angular momentum of light. Our work presents a unified view on spin-momentum locking and how it affects optical forces on chiral and achiral particles.

  11. A novel mode-locking technique

    International Nuclear Information System (INIS)

    Chen Shaoh; Chen Youming; Chen Taolue; Si Xiangdong; Yang Yi; Deng Ximing

    1993-01-01

    A novel mode-locked Nd:YAG oscillator has been developed by using an ultrafast photoconductive feedback controlled loop, and mode-locked pulses with a duration of 100ps have been obtained. The energy instability of the pulse trains is ±5%. In this type of mode-locking technology, a type of deep-level doped GaAs (Cr-doped) photoconductive switch, which has a fast response in time and is free of avalance process, is used to drive a Pockels' cell to realize mode-locking. The dark resistance of this type of photoconductive switch is 6 orders of magnitude higher than that of the intrinsic single-crystal silicon, and it can reach a level as high as 10 9 ohms. Consequently, it is able to withstand longterm operation at several thousand DC volts. By means of the photoconductive ohmic switch characteristics, the authors have designed a positive feedback control network which has a very fast response time, and can couple a voltage of up to a thousand volts. Using this unit in a Nd:YAG laser, they have successfully realized a very stable mode-locked pulse train with pulse width shorter than 100 ps. The operation principle, and the results of the preliminary experiments are presented here. 1 ref., 3 figs

  12. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.

    Science.gov (United States)

    Kim, Ji Wan; Oh, Chang-Wug; Byun, Young-Soo; Kim, Jung Jae; Park, Ki Chul

    2015-04-01

    To compare the clinical and radiologic results of conventional open plating (COP) and minimally invasive plate osteosynthesis (MIPO) in the treatment of noncomminuted humeral shaft fractures. Randomized prospective study. Five level 1 trauma centers. Sixty-eight consecutive patients were randomized into 2 study groups: those treated by COP (COP group; n = 32) and those treated by MIPO (MIPO group; n = 36). Simple humeral shaft fractures (AO/OTA classification types A and B) were reduced by open reduction or closed reduction and fixed with a narrow 4.5/5.0 locking compression plate, metaphyseal locking compression plate, or proximal humeral internal locking system plate to the anterior lateral aspect of the humerus. Fracture healing time, operative time, radiation exposure time, and intraoperative nerve injury. To assess shoulder and elbow function, we used the University of California, Los Angeles (UCLA) scoring system and the Mayo elbow performance index, including the range of motion and pain. Radiographic measurements included fracture alignment, delayed union, and nonunion. Thirty-one fractures (97%) healed in the COP group within 16 weeks, whereas 36 fractures (100%) were healed in the MIPO group by 15 weeks. No significant difference was observed in the operative time or complication rates. In both groups, all fractures achieved union without malunion and with excellent functional outcomes by definition of the Mayo elbow performance index and UCLA scoring system. This study confirmed a high overall rate of union and excellent functional outcomes in both MIPO and COP groups. MIPO is equivalent to COP as a safe and effective method for simple types of humeral shaft fractures when surgery is indicated, and the surgeon is experienced in the technique. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  13. Hersendood. Mackies leibniziaanse herinterpretatie van Lockes theorie van persoonsidentiteit

    OpenAIRE

    De Vleeschouwer, Gregory

    2009-01-01

    In his book, 'Problems from Locke', John Leslie Mackie presents a theory of personal identity (pi) that is meant to be a supplement and correction of Locke's pi-theory. In a first part I introduce the criterion of pi that was standard before Locke's pi-theory. By showing in a second part how Locke reacted against this traditional criterion, I show wherein the singularity of Locke's pi-theory exists. In a third part I explain how Leibniz is moved by the same solicitude as Locke, but also how h...

  14. Paper microzone plates.

    Science.gov (United States)

    Carrilho, Emanuel; Phillips, Scott T; Vella, Sarah J; Martinez, Andres W; Whitesides, George M

    2009-08-01

    This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multiwell plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (approximately 180 microm), require small volumes of sample (5 microL per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (approximately 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was approximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader.

  15. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware.

    Science.gov (United States)

    Windolf, Markus; Klos, Kajetan; Wähnert, Dirk; van der Pol, Bas; Radtke, Roman; Schwieger, Karsten; Jakob, Roland P

    2010-05-21

    Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence") utilizing conventional (non-locked) implants in comparison to conventional LC-DCP (limited contact dynamic compression plate) and LCP (locking compression plate) stabilization, in a human cadaveric diaphyseal gap model. In eight pairs of human cadaveric femora, one femur per pair was randomly assigned to receive a Fence construct with either elevated or non-elevated plate, while the contralateral femur received either an LCP or LC-DCP instrumentation. Fracture gap motion and fatigue performance under cyclic loading was evaluated successively in axial compression and in torsion. Results were statistically compared in a pairwise setting. The elevated Fence constructs allowed significantly higher gap motion compared to the LCP instrumentations (axial compression: p concept can be of interest in cases were angle-stable implants are unavailable and can lead to new strategies in implant design.

  16. Treatment of segmental tibial fractures with supercutaneous plating.

    Science.gov (United States)

    He, Xianfeng; Zhang, Jingwei; Li, Ming; Yu, Yihui; Zhu, Limei

    2014-08-01

    Segmental tibial fractures usually follow a high-energy trauma and are often associated with many complications. The purpose of this report is to describe the authors' results in the treatment of segmental tibial fractures with supercutaneous locking plates used as external fixators. Between January 2009 and March 2012, a total of 20 patients underwent external plating (supercutaneous plating) of the segmental tibial fractures using a less-invasive stabilization system locking plate (Synthes, Paoli, Pennsylvania). Six fractures were closed and 14 were open (6 grade IIIa, 2 grade IIIb, 4 grade II, and 2 grade I, according to the Gustilo classification). When imaging studies confirmed bone union, the plates and screws were removed in the outpatient clinic. Average time of follow-up was 23 months (range, 12-47 months). All fractures achieved union. Median time to union was 19 weeks (range, 12-40 weeks) for the proximal fractures and 22 weeks (range, 12-42 weeks) for the distal fractures. Functional results were excellent in 17 patients and good in 3. Delayed union of the fracture occurred in 2 patients. All patients' radiographs showed normal alignment. No rotational deformities and leg shortening were seen. No incidences of deep infection or implant failures occurred. Minor screw tract infection occurred in 2 patients. A new 1-stage protocol using supercutaneous plating as a definitive fixator for segmental tibial fractures is less invasive, has a lower cost, and has a shorter hospitalization time. Surgeons can achieve good reduction, soft tissue reconstruction, stable fixation, and high union rates using supercutaneous plating. The current patients obtained excellent knee and ankle joint motion and good functional outcomes and had a comfortable clinical course. Copyright 2014, SLACK Incorporated.

  17. Discretely tunable micromachined injection-locked lasers

    International Nuclear Information System (INIS)

    Cai, H; Yu, M B; Lo, G Q; Kwong, D L; Zhang, X M; Liu, A Q; Liu, B

    2010-01-01

    This paper reports a micromachined injection-locked laser (ILL) to provide tunable discrete wavelengths. It utilizes a non-continuously tunable laser as the master to lock a Fabry–Pérot semiconductor laser chip. Both lasers are integrated into a deep-etched silicon chip with dimensions of 3 mm × 3 mm × 0.8 mm. Based on the experimental results, significant improvements in the optical power and spectral purity have been achieved in the fully locked state, and optical hysteresis and bistability have also been observed in response to the changes of the output wavelength and optical power of the master laser. As a whole system, the micromachined ILL is able to provide single mode, discrete wavelength tuning, high power and direct modulation with small size and single-chip solution, making it promising for advanced optical communications such as wavelength division multiplexing optical access networks.

  18. Weak-light phase locking for LISA

    International Nuclear Information System (INIS)

    McNamara, Paul W

    2005-01-01

    The long armlengths of the LISA interferometer, and the finite aperture of the telescope, lead to an optical power attenuation of ∼10 -10 of the transmitted to received light. Simple reflection at the end of the arm is therefore not an optimum interferometric design. Instead, a local laser is offset phase locked to the weak incoming beam, transferring the phase information of the incoming to the outgoing light. This paper reports on an experiment to characterize a weak-light phase-locking scheme suitable for LISA in which a diode-pumped, Nd:YAG, non-planar ring oscillator (NPRO) is offset phase locked to a low-power (13 pW) frequency stabilized master NPRO. Preliminary results of the relative phase noise of the slave laser shows shot noise limited performance above 0.4 Hz. Excess noise is observed at lower frequencies, most probably due to thermal effects in the optical arrangement and phase-sensing electronics

  19. Using river locks to teach hydrodynamic concepts

    Science.gov (United States)

    Carvalho-Santos, Vagson L.; Mendes, Thales C.; Silva, Enisvaldo C.; Rios, Márcio L.; Silva, Anderson A. P.

    2013-11-01

    In this work, the use of a river lock as a non-formal setting for teaching hydrodynamical concepts is proposed. In particular, we describe the operation of a river lock situated at the Sobradinho dam, on the São Francisco River (Brazil). A model to represent and to analyse the dynamics of river lock operation is presented and we derive the dynamical equations for the rising of the water column as an example to understand the Euler equation. Furthermore, with this activity, we enable the integration of content initially introduced in the classroom with practical applications, thereby allowing the association of physical themes to content relevant in disciplines such as history and geography. In addition, experiences of this kind enable teachers to talk about the environmental and social impacts caused by the construction of a dam and, consequently, a crossover of concepts has been made possible, leading to more meaningful learning for the students.

  20. Using river locks to teach hydrodynamic concepts

    International Nuclear Information System (INIS)

    Carvalho-Santos, Vagson L; Mendes, Thales C; Silva, Enisvaldo C; Rios, Márcio L; Silva, Anderson A P

    2013-01-01

    In this work, the use of a river lock as a non-formal setting for teaching hydrodynamical concepts is proposed. In particular, we describe the operation of a river lock situated at the Sobradinho dam, on the São Francisco River (Brazil). A model to represent and to analyse the dynamics of river lock operation is presented and we derive the dynamical equations for the rising of the water column as an example to understand the Euler equation. Furthermore, with this activity, we enable the integration of content initially introduced in the classroom with practical applications, thereby allowing the association of physical themes to content relevant in disciplines such as history and geography. In addition, experiences of this kind enable teachers to talk about the environmental and social impacts caused by the construction of a dam and, consequently, a crossover of concepts has been made possible, leading to more meaningful learning for the students. (paper)

  1. John Locke and the right to resistance

    Directory of Open Access Journals (Sweden)

    Jovanov Ilija D.

    2015-01-01

    Full Text Available John Locke was a great thinker and many works have been devoted to clear up his theories. One of the most significant, stated in his principal work, Two Treatises of Government, is the theory of the right to resistance. It was a bit revolutionary then, and to a large extent it is today. Domination of legal positivism is negation of that, by Locke, natural right. However, the fact is that in recent times the resistance to the established power occurs in a number of countries and in different forms, so that the idea of the right to resistance becomes live question again. In this regard it is interesting to consider Locke's viewpoint on this important issue and to determine whether his theory on the resistance is applicable in modern societies.

  2. SWITCHED REFERENCE PHASE LOCK LOOP (SRPLL)

    International Nuclear Information System (INIS)

    KERNER, T.

    2001-01-01

    The Brookhaven National Laboratory Relativistic Heavy Ion Collider (RHIC) has two beam synchronous event links (BSL), one for each ring, which use the 28 MHz ring low level rf to distribute event codes synchronously with a precise phase relationship to the beam. During a cogging reset just before injection, the low level rf sine wave is interrupted which causes the BSL receivers to lose lock. Lock loss in turn causes false triggers and other undesirable-effects on the beam position monitors (BPM), ionization profile monitors (IPM), the tune meter and various experiments which use the BSLs. To rectify these problems, a SRPLL has been inserted between the beam synchronous master and the low level rf source. The SRPLL inserts a frequency and phase continuous splice over the dead-band gap in the rf source created during a cogging reset. The splice removes the gap and prevents the distributed BSL receivers from losing lock

  3. The study of 80 MHz self starting passively mode-locked Erbium-Doped Fiber Laser via nonlinear polarization rotation with SESAM

    International Nuclear Information System (INIS)

    Qamar, F.

    2013-01-01

    Erbium-Doped Fiber Laser, EDF L, passively mode-locked via only Nonlinear Polarization Rotation, NPR, and via NPR with Semiconductor Saturable Absorber Mirror, SESAM, is studied. Self start single pulse train with pulse width of 114 fs and repetition rate (PRR) of 80 MHz has been obtained when 55 cm EDFL, passively mode-locked via NPR only. Inserting SESAM in EDFL cavity leads to shorten the pulse width up to 88 fs, increases the amplitude stability up to 96% and lower the phase noise jittering to around 26 fsec. Stable second harmonic self starting passively mode-locked EDFL with pulse width of 284 fs has also been observed only when SESAM was used in the cavity. Multi-pulsed system passively mode-locked via NPR for EDFL length of 80 cm with time difference between the successive multi-pulses ranged from few picoseconds to nanoseconds, has been observed. The time difference can be controlled by the polarizer controller and the half wave plate. Further controlling of the cavity polarization leads to developing the multiple mode locking pulses train to second harmonic mode-locking pulse train with PRR of 160MHz and pulse width of 156 fs. Three harmonic superposed trains of mode locked pulse have been achieved only when SESAM added to the cavity. (author)

  4. High-Order Frequency-Locked Loops

    DEFF Research Database (Denmark)

    Golestan, Saeed; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    In very recent years, some attempts for designing high-order frequency-locked loops (FLLs) have been made. Nevertheless, the advantages and disadvantages of these structures, particularly in comparison with a standard FLL and high-order phase-locked loops (PLLs), are rather unclear. This lack...... study, and its small-signal modeling, stability analysis, and parameter tuning are presented. Finally, to gain insight about advantages and disadvantages of high-order FLLs, a theoretical and experimental performance comparison between the designed second-order FLL and a standard FLL (first-order FLL...

  5. Mode-locked silicon evanescent lasers.

    Science.gov (United States)

    Koch, Brian R; Fang, Alexander W; Cohen, Oded; Bowers, John E

    2007-09-03

    We demonstrate electrically pumped lasers on silicon that produce pulses at repetition rates up to 40 GHz. The mode locked lasers generate 4 ps pulses with low jitter and extinction ratios above 18 dB, making them suitable for data and telecommunication transmitters and for clock generation and distribution. Results of both passive and hybrid mode locking are discussed. This type of device could enable new silicon based integrated technologies, such as optical time division multiplexing (OTDM), wavelength division multiplexing (WDM), and optical code division multiple access (OCDMA).

  6. Drag and Torque on Locked Screw Propeller

    Directory of Open Access Journals (Sweden)

    Tomasz Tabaczek

    2014-09-01

    Full Text Available Few data on drag and torque on locked propeller towed in water are available in literature. Those data refer to propellers of specific geometry (number of blades, blade area, pitch and skew of blades. The estimation of drag and torque of an arbitrary propeller considered in analysis of ship resistance or propulsion is laborious. The authors collected and reviewed test data available in the literature. Based on collected data there were developed the empirical formulae for estimation of hydrodynamic drag and torque acting on locked screw propeller. Supplementary CFD computations were carried out in order to prove the applicability of the formulae to modern moderately skewed screw propellers.

  7. John Locke on persons and personal identity

    OpenAIRE

    Boeker, Ruth

    2013-01-01

    John Locke claims both that ‘person’ is a forensic term and that personal identity consists in sameness of consciousness. The aim of my dissertation is to explain and critically assess how Locke links his moral and legal account of personhood to his account of personal identity in terms of sameness of consciousness. My interpretation of Locke’s account of persons and personal identity is embedded in Locke’s sortal-dependent account of identity. Locke’s sortal-dependent ac...

  8. Optimal database locks for efficient integrity checking

    DEFF Research Database (Denmark)

    Martinenghi, Davide

    2004-01-01

    In concurrent database systems, correctness of update transactions refers to the equivalent effects of the execution schedule and some serial schedule over the same set of transactions. Integrity constraints add further semantic requirements to the correctness of the database states reached upon...... the execution of update transactions. Several methods for efficient integrity checking and enforcing exist. We show in this paper how to apply one such method to automatically extend update transactions with locks and simplified consistency tests on the locked entities. All schedules produced in this way...

  9. Nuclear reactor incorporating locking device for threaded bolt connections

    International Nuclear Information System (INIS)

    Blaushild, R.M.

    1987-01-01

    A nuclear reactor having a pressure vessel and a first element is described comprising a core barrel situated within the pressure vessel. The core barrel has a baffle former secured in and to the core barrel by bolted connections, and a second element comprising baffle plates secured to the inner surface of the baffle former by bolted connections, with a locking device to prevent loosening of bolted connections between the baffle former and at least one of the elements. The baffle former and at least one element are held together by a headed, threaded bolt engaged in a bore coaxially extending in the baffle former and at least one element and threadedly engaged in a threaded section in at least the baffle former. The threaded section has first threaded of a first direction, with the head of the bolt engaged with a shoulder about the bore in at least one element to hold the baffle formed and at least one element together, the head of the bolt having a first diameter and a cavity, having an unsymmetrical wall thereabout, in the end surface thereof. It comprises a recess in at least one element coaxial with the bore forming a wall thereabout and extending inwardly from the outer surface of at least one element, the recess having a second diameter greater than the first diameter, with at least one element having second threads in the wall of a direction opposite the direction of the first threads of the threaded bore; a locking nut having a base with a downwardly depending cylindrical wall thereabout

  10. Navigation Study, Colorado Locks, Colorado River, Matagorda, Texas

    National Research Council Canada - National Science Library

    McCollum, Randy

    2000-01-01

    A 1:70 physical navigation model was built to replicate the Matagorda Locks, approximately one mile of the GIWW east of the locks, approximately one-half mile of the Colorado River north of the GIWW...

  11. Robust tilt and lock mechanism for hopping actuator

    Energy Technology Data Exchange (ETDEWEB)

    Salton, Jonathan R.; Buerger, Stephen; Dullea, Kevin J.; Marron, Lisa C.; Salisbury, Curt Michael; Spletzer, Barry Louis

    2017-02-07

    A tilt and lock apparatus that includes a tilt servomechanism, a spiral torsion spring, a lock wheel, and a lock hook is described herein. The spiral torsion spring is mechanically coupled to the tilt servomechanism and the lock wheel (which includes an opening). When a shaft is positioned through the opening, rotation of the lock wheel is in unison with rotation of the shaft. An external surface of the lock wheel includes one or more grooves. The lock hook includes a head that engages and disengages the grooves. The lock wheel is stationary when the head engages one of the grooves and is rotatable when the head disengages the grooves. The head and the grooves are geometrically aligned when engaged to prevent creation of a force that acts to disengage the head responsive to an applied force acting on the shaft.

  12. Gradual unlocking of plate boundary controlled initiation of the 2014 Iquique earthquake.

    Science.gov (United States)

    Schurr, Bernd; Asch, Günter; Hainzl, Sebastian; Bedford, Jonathan; Hoechner, Andreas; Palo, Mauro; Wang, Rongjiang; Moreno, Marcos; Bartsch, Mitja; Zhang, Yong; Oncken, Onno; Tilmann, Frederik; Dahm, Torsten; Victor, Pia; Barrientos, Sergio; Vilotte, Jean-Pierre

    2014-08-21

    On 1 April 2014, Northern Chile was struck by a magnitude 8.1 earthquake following a protracted series of foreshocks. The Integrated Plate Boundary Observatory Chile monitored the entire sequence of events, providing unprecedented resolution of the build-up to the main event and its rupture evolution. Here we show that the Iquique earthquake broke a central fraction of the so-called northern Chile seismic gap, the last major segment of the South American plate boundary that had not ruptured in the past century. Since July 2013 three seismic clusters, each lasting a few weeks, hit this part of the plate boundary with earthquakes of increasing peak magnitudes. Starting with the second cluster, geodetic observations show surface displacements that can be associated with slip on the plate interface. These seismic clusters and their slip transients occupied a part of the plate interface that was transitional between a fully locked and a creeping portion. Leading up to this earthquake, the b value of the foreshocks gradually decreased during the years before the earthquake, reversing its trend a few days before the Iquique earthquake. The mainshock finally nucleated at the northern end of the foreshock area, which skirted a locked patch, and ruptured mainly downdip towards higher locking. Peak slip was attained immediately downdip of the foreshock region and at the margin of the locked patch. We conclude that gradual weakening of the central part of the seismic gap accentuated by the foreshock activity in a zone of intermediate seismic coupling was instrumental in causing final failure, distinguishing the Iquique earthquake from most great earthquakes. Finally, only one-third of the gap was broken and the remaining locked segments now pose a significant, increased seismic hazard with the potential to host an earthquake with a magnitude of >8.5.

  13. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware

    Directory of Open Access Journals (Sweden)

    Radtke Roman

    2010-05-01

    Full Text Available Abstract Background Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence" utilizing conventional (non-locked implants in comparison to conventional LC-DCP (limited contact dynamic compression plate and LCP (locking compression plate stabilization, in a human cadaveric diaphyseal gap model. Methods In eight pairs of human cadaveric femora, one femur per pair was randomly assigned to receive a Fence construct with either elevated or non-elevated plate, while the contralateral femur received either an LCP or LC-DCP instrumentation. Fracture gap motion and fatigue performance under cyclic loading was evaluated successively in axial compression and in torsion. Results were statistically compared in a pairwise setting. Results The elevated Fence constructs allowed significantly higher gap motion compared to the LCP instrumentations (axial compression: p ≤ 0.011, torsion p ≤ 0.015 but revealed similar performance under cyclic loading (p = 0.43. The Fence instrumentation with established bone-plate contact revealed larger fracture gap motion under axial compression compared to the conventional LC-DCP osteosynthesis (p ≤ 0.017. However, all contact Fence specimens survived the cyclic test, whereas all LC-DCP constructs failed early during torsion testing (p Conclusions Even though accentuated fracture gap motion became obvious, the "Fence" technique is considered an alternative to cost-intensive locking-head devices. The concept can be of interest in cases were angle-stable implants are unavailable and can lead to new strategies in implant design.

  14. Locks at reactor safety containments of nuclear power plants

    International Nuclear Information System (INIS)

    1978-12-01

    The rule is to be applied for material access locks. A material access lock as defined by this rule is a pressure resistant and technically gas-tight hollow body that is connected with the containment and has got two doors, the inner door of which connects the lock chamber with the interior of the containment and the outer door connects the lock chamber with the outside. It serves exclusively for transferring material or objects. (orig./HP) [de

  15. Performance Monitoring System: Summary of Lock Statistics. Revision 1.

    Science.gov (United States)

    1985-12-01

    2751 84 4057 4141 526 798 18 1342 5727 19 5523 3996 4587 8583 1056 1630 35 2721 6536LOCK A DAMI 2 AUXILIARY I Ins NO DATA RECORDD FOR THIS LOCK- " LOCK I...TOTAL (KTOMS) ’ - (AVt OPNP ETC) ’’ ,q [ " ARKANSAS RIVER "" FORRELL LOCK IP 7A/3TRC 9/N83 UPBOUID STATISTICS ISO 53 42 M6 553 356 909 221 41 21 M8

  16. Multiprocessor Real-Time Locking Protocols for Replicated Resources

    Science.gov (United States)

    2016-07-01

    assignment problem, the ac- tual identities of the allocated replicas must be known. When locking protocols are used, tasks may experience delays due to both...Multiprocessor Real-Time Locking Protocols for Replicated Resources ∗ Catherine E. Jarrett1, Kecheng Yang1, Ming Yang1, Pontus Ekberg2, and James H...replicas to execute. In prior work on replicated resources, k-exclusion locks have been used, but this restricts tasks to lock only one replica at a time. To

  17. Imaging in percutaneous musculoskeletal interventions

    International Nuclear Information System (INIS)

    Gangi, Afshin; Guth, Stephane; Guermazi, Ali

    2009-01-01

    This is one of the first books to deal specifically with imaging in percutaneous musculoskeletal interventions. The use of different imaging modalities during these procedures is well described. In the first chapter, the basic procedures and different guidance techniques are presented and discussed. The ensuing chapters describe in exhaustive detail the abilities and uses of imaging in guiding procedures ranging from biopsy and joint injection to management of pain and tumors. These procedures are extensively documented in adults as well as in the pediatric population. The third part of the book describes the different indications for vascular interventions in musculoskeletal lesions. The final chapter focuses on ultrasound-guided interventions, as they are more common and tend to be fashionable. The book is well illustrated with carefully chosen and technically excellent images. Each of the 18 chapters is written by an expert of international repute, making this book the most current and complete treatment of the subject available. It should be of great interest to interventional radiologists and also musculoskeletal and general radiologists. (orig.)

  18. Percutaneous tracheostomy--special considerations.

    Science.gov (United States)

    Ernst, Armin; Critchlow, Jonathan

    2003-09-01

    Percutaneous tracheostomy is safe and highly effective in well-trained hands in establishing a long-term artificial airway. Most alleged contraindications and some suggestions on how the procedures should be performed likely stem from early trials when only "perfect candidates" were chosen. Most of those contraindications should not be viewed as prohibitions, but as suggestions related to the skill level and training of the operator. We have used this technique in many situations where the small incision and tamponading effect of the tracheostomy tube has been quite beneficial, in selected patients with coagulapathies and severe venous congestion from superior cava syndromes as well as thyroid cancers, and in whom operative approaches would have been difficult. Knowing one's level of expertise and comfort in choosing and rejecting patients and procedures accordingly is the key to keeping PT a procedure with an excellent safety record. As the experience with PT grows, more and more perceived contraindications will disappear. Studies will address the role of PT in children and as a means of establishing emergent airway access. Also, the exact coagulation limits will need to be established. Few contraindications will most likely remain absolute, such as active infections over the proposed entry site, uncontrollable bleeding disorders and excessive ventilatory and oxygenation requirements. In our institution, taking into account these absolute contraindications, fewer than 5% of patients in need of a tracheostomy in the intensive care unit will undergo a primary open procedure.

  19. Lock-free parallel garbage collection

    NARCIS (Netherlands)

    H. Gao; J.F. Groote (Jan Friso); W.H. Hesselink (Wim)

    2005-01-01

    htmlabstract This paper presents a lock-free parallel algorithm for mark&sweep garbage collection (GC) in a realistic model using synchronization primitives compare-and-swap (CAS) and load-linked/store-conditional (LL/SC) offered by machine architectures. Mutators and collectors can simultaneously

  20. A Mode Locked UV-FEL

    CERN Document Server

    Parvin, Parviz

    2004-01-01

    An appropriate resonator has been designed to generate femtosecond mode locked pulses in a UV FEL with the modulator performance based on the gain switching. The gain broadening due to electron energy spread affects on the gain parameters, small signal gain (γ0) and saturation intensity (Is), to determine the optimum output coupling as small.

  1. CMOS switched current phase-locked loop

    NARCIS (Netherlands)

    Leenaerts, D.M.W.; Persoon, G.G.; Putter, B.M.

    1997-01-01

    The authors present an integrated circuit realisation of a switched current phase-locked loop (PLL) in standard 2.4 µm CMOS technology. The centre frequency is tunable to 1 MHz at a clock frequency of 5.46 MHz. The PLL has a measured maximum phase error of 21 degrees. The chip consumes

  2. Phase locking of optically coupled lasers

    International Nuclear Information System (INIS)

    Glova, A F

    2003-01-01

    A review of studies of the properties of radiation from optically coupled lasers is presented. The methods for phase locking the fields in optically coupled lasers of different types are considered and the methods for supermode selection and correction of the radiation pattern are discussed. (review)

  3. A locked nucleic Acid-based nanocrawler

    DEFF Research Database (Denmark)

    Astakhova, I Kira; Pasternak, Karol; Campbell, Meghan A

    2013-01-01

    Herein we introduce a novel fluorescent LNA/DNA machine, a nanocrawler, which reversibly moves along a directionally polar complementary road controlled by affinity-enhancing locked nucleic acid (LNA) monomers and additional regulatory strands. Polyaromatic hydrocarbon (PAH) dyes attached to 2...

  4. 49 CFR 236.742 - Dog, locking.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Dog, locking. 236.742 Section 236.742 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.742 Dog...

  5. A New Perspective on Job Lock

    Science.gov (United States)

    Huysse-Gaytandjieva, Anna; Groot, Wim; Pavlova, Milena

    2013-01-01

    This paper analyses the situation when employees fail to adapt to overall job dissatisfaction. By combining the existing knowledge in economics on job lock and in psychology on employees' feeling of being "stuck" at work, the paper explains why some employees fail to adapt when dissatisfied with their job. Thus, the paper aims to expand…

  6. Locks & keys service moves to building 55

    CERN Multimedia

    2012-01-01

    Please note that as of July 12 Locks & keys service will be at building 55 second floor. The opening hours are as follows: 08:30 am to 12:30 pm - 1:30 pm to 5:30 pm. The procedures and rules relating to applications for key and cylinder have not changed. GI-IS Group

  7. Create Your Plate

    Medline Plus

    Full Text Available ... Type 2 Diabetes Know Your Rights Employment Discrimination Health Care Professionals Law ... Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ...

  8. Create Your Plate

    Medline Plus

    Full Text Available ... Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday ... Carbohydrates Types of Carbohydrates Carbohydrate Counting Make Your Carbs ...

  9. A photovoltaic module diagnostic setup for lock-in-thermography and lock-in electroluminescence imaging

    DEFF Research Database (Denmark)

    Parikh, Harsh; Spataru, Sergiu; Sera, Dezso

    2018-01-01

    Electroluminescence (EL) imaging and infrared (IRT) thermography techniques have become indispensable tools in recent years for health diagnostic of PV modules in solar industry application. Complementary to these imaging methods, lock-in techniques can effectively remove noise by periodically...... modulating the input signal and averaging it over a desired number of periods. We propose a combined lock-in EL and lock-in IRT diagnostic setup for accurate analysis of different types of faults occurring in a solar module. The setup is built around a Goldeye CL-033 high-speed SWIR camera, which can acquire...... experimental work on a (36/72) cell solar module using combined (EL) or (IRT) lock-in-thermography. The setup allows one to investigate the different technological problems that can occur when performing PV diagnostics in drone-based inspections....

  10. Navigation Study of Lower Lock Approach, John Day Lock and Dam, Columbia River, Oregon

    National Research Council Canada - National Science Library

    Wilson, Donald

    2001-01-01

    Representatives of the Columbia River Towing Association reported recent structural and/or operational changes at John Day Lock and Dam have created difficult navigation conditions for tows entering...

  11. 30 CFR 56.12068 - Locking transformer enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  12. Dynamic locking screw improves fixation strength in osteoporotic bone: an in vitro study on an artificial bone model.

    Science.gov (United States)

    Pohlemann, Tim; Gueorguiev, Boyko; Agarwal, Yash; Wahl, Dieter; Sprecher, Christoph; Schwieger, Karsten; Lenz, Mark

    2015-04-01

    The novel dynamic locking screw (DLS) was developed to improve bone healing with locked-plate osteosynthesis by equalising construct stiffness at both cortices. Due to a theoretical damping effect, this modulated stiffness could be beneficial for fracture fixation in osteoporotic bone. Therefore, the mechanical behaviour of the DLS at the screw-bone interface was investigated in an artificial osteoporotic bone model and compared with conventional locking screws (LHS). Osteoporotic surrogate bones were plated with either a DLS or a LHS construct consisting of two screws and cyclically axially loaded (8,500 cycles, amplitude 420 N, increase 2 mN/cycle). Construct stiffness, relative movement, axial screw migration, proximal (P) and distal (D) screw pullout force and loosening at the bone interface were determined and statistically evaluated. DLS constructs exhibited a higher screw pullout force of P 85 N [standard deviation (SD) 21] and D 93 N (SD 12) compared with LHS (P 62 N, SD 28, p = 0.1; D 57 N, SD 25, p LHS (p = 0.01). DLS constructs showed significantly lower axial construct stiffness (403 N/mm, SD 21, p LHS (529 N/mm, SD 27; 0.8 mm, SD 0.04). Based on the model data, the DLS principle might also improve in vivo plate fixation in osteoporotic bone, providing enhanced residual holding strength and reducing screw cutout. The influence of pin-sleeve abutment still needs to be investigated.

  13. Effect of instability of vortex streets behind circular cylinder on lock-in oscillation

    International Nuclear Information System (INIS)

    Masaya Kondo

    2005-01-01

    Full text of publication follows: The effects of the instability of vortex streets formed in the wakes of a circular cylinder on lock-in oscillation was investigated using a splitter plate and a phase-estimation methodology. The lock-in oscillation at the reduced velocity of 2.5 ≤ Vr < ∼ 3.5 is a self excited oscillation with alternate vortices. The amplitude of the lock-in oscillation is changed with the reduced velocity, although the oscillation frequency and the external force frequency caused by vortices is insensitive to the reduced velocity. Author reported that the amplitude changed with the energy input, which changed with the relationship between the phase of the external force and the phase of the cylinder displacement. The report suggested that the timing of the vortices shedding would change with the reduced velocity. The reason of the timing change, however, has not been clarified yet. This paper presents an explanation of the timing change using the instability of the vortex streets formed in the wake. The distance with a next vortex in a vortex street behind a cylinder at the lock-in condition changes with reduced velocity. On the assumption that the distance between two vortex streets formed in a wake of the cylinder is a constant, only one reduced velocity satisfied the stable condition called 'Karman Vortex Street'. It means that two vortex streets formed at the lock-in condition would be instable essentially, and the vortices would interact each other to form the stable condition. The interaction among the vortices would affect not only for the shed vortices in the wake but also for the growing-up vortex on the cylinder surface. Therefore, the instability of the vortex streets would affect the timing of the vortices shedding. A flow-induced oscillation test using a circular cylinder with a splitter plate was performed to confirm such an instability. The splitter plate was installed in the far wake of the cylinder to terminate the interaction

  14. Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture

    OpenAIRE

    Wu, Ai-Min; Jin, Hai-Ming; Lin, Zhong-Ke; Chi, Yong-Long; Wang, Xiang-Yang

    2017-01-01

    Background The objective of this study is to investigate the outcomes and safety of using percutaneous anterior C1/2 transarticular screw fixation as a salvage technique for odontoid fracture if percutaneous odontoid screw fixation fails. Methods Fifteen in 108 odontoid fracture patients (planned to be treated by percutaneous anterior odontoid screw fixation) were failed to introduce satisfactory odontoid screw trajectory. To salvage this problem, we chose the percutaneous anterior C1/2 trans...

  15. Biomechanical study of percutaneous lumbar diskectomy

    International Nuclear Information System (INIS)

    Li Yuan; Huang Xianglong; Shen Tianzhen; Hu Zhou; Hong Shuizong; Mei Haiying

    2003-01-01

    Objective: To investigate the stiffness of lumbar spine after the injury caused by percutaneous diskectomy and evaluate the efficiency of percutaneous lumbar diskectomy by biomechanical study. Methods: Four fresh lumbar specimens were used to analyse load-displacement curves in the intact lumbar spine and vertical disc-injured lumbar spine. The concepts of average flexibility coefficient (f) and standardized average flexibility coefficient (fs) were also introduced. Results: The load-displacement curves showed a good stabilization effect of the intact lumbar spine and disc-injured lumbar spine in flexion, extension, right and left bending. The decrease of anti-rotation also can be detected (P<0.05). Conclusion: In biomechanical study, percutaneous lumbar diskectomy is one of the efficiency methods to treat lumbar diac hernia

  16. Percutaneous management of staghorn renal calculi

    International Nuclear Information System (INIS)

    Lee, Won Jay

    1989-01-01

    During a four year period, ending May 1987, 154 cases of symptomatic staghorn calculi have been treated by percutaneous nephrolithotomy. Of these patients,86% were discharged completely stone free with the remainder having fragments less than 5 mm in greatest diameter. More than one operative procedure during the same hospitalizations was required in 24% of patients and multiple percutaneous tracts were established in excess of 73% of them. Significant complications occurred in 16% of patients and there was one death. Most complications can be generally by minimized by careful approach and manageable by interventional radiological means. The management of patients with staghorn calculi requires a comprehensive understanding of the renal anatomy, selection of appropriate percutaneous nephrostomy tract sites, and radiologic-urologic expertise needed to remove the large stone mass. The advent of extracorporeal shock wave lithotripsy will not abolish the need for nephrolithotomy, particularly complex stones such as staghorn calculi

  17. Ambulatory percutaneous nephrolithotomy: initial series.

    Science.gov (United States)

    Shahrour, Walid; Andonian, Sero

    2010-12-01

    To assess the safety and feasibility of ambulatory percutaneous nephrolithotomy (PCNL). PCNL is the gold standard for the management of large renal stones. Although tubeless PCNL has been previously described, no case series have been published of ambulatory PCNL. The criteria for ambulatory PCNL were: single tract, stone-free status documented by flexible nephroscopy, adequate pain control, and satisfactory postoperative hematocrit level and chest radiographic findings. Patient information, including operating room and fluoroscopy times, stone size and Hounsfield units, and number of needle punctures, were collected prospectively. The time spent in the recovery room, in addition to the amount of narcotics used in the recovery room and at home, was documented. Of 10 patients, 8 had nephrostomy tracts established intraoperatively by the urologist and 2 had preoperative nephrostomy tubes placed. The median operating and fluoroscopy time was 83.5 and 4.45 minutes, respectively. The median stone diameter was 20 mm (800 Hounsfield units) in addition to a patient with a staghorn calculus. The patients spent a median of 240 minutes in the recovery room and had received a median of 19.25 mg of morphine equivalents. Only 3 patients (30%) used narcotics at home. No intraoperative complications occurred, and none of the patients required transfusions. Two postoperative complications developed: a deep vein thrombosis requiring outpatient anticoagulation and multiresistant Escherichia coli infection requiring intravenous antibiotics. In highly selected patients, ambulatory PCNL is safe and feasible. More patients are needed to verify the criteria for patients undergoing the ambulatory approach. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Percutaneous endoscopic gastrostomy in children

    Directory of Open Access Journals (Sweden)

    Jye Hae Park

    2011-01-01

    Full Text Available Purpose: Percutaneous endoscopic gastrostomy (PEG can improve nutritional status and reduce the amount of time needed to feed neurologically impaired children. We evaluated the characteristics, complications, and outcomes of neurologically impaired children treated with PEG. Methods: We retrospectively reviewed the records of 32 neurologically impaired children who underwent PEG between March 2002 and August 2008 at our medical center. Forty-two PEG procedures comprising 32 PEG insertions and 10 PEG exchanges, were performed. The mean follow-up time was 12.2 (6.6 months. Results: Mean patient age was 9.4 (4.5 years. The main indications for PEG insertion were swallowing difficulty with GI bleeding due to nasogastric tube placement and/or the presence of gastroesophageal reflux disease (GERD. The overall rate of complications was 47%, with early complications evident in 25% of patients and late complications in 22%. The late complications included one gastro-colic fistula, two cases of aggravated GERD, and four instances of wound infection. Among the 15 patients with histological evidence of GERD before PEG, 13 (87% had less severe GERD, experienced no new aspiration events, and showed increased body weight after PEG treatment. Conclusion: PEG is a safe, effective, and relatively simple technique affording long-term enteral nutritional support in neurologically impaired children. Following PEG treatment, the body weight of most patients increased and the levels of vomiting, GI bleeding, and aspiration fell. We suggest that PEG with post-procedural observation be considered for enteral nutritional support of neurologically impaired children.

  19. Create Your Plate

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Create Your Plate Create Your Plate is a ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal Planning ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ... Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods ...

  2. Create Your Plate

    Medline Plus

    Full Text Available ... ready, you can try new foods within each food category. Try these seven steps to get started: Using your dinner plate, put a line down the middle of the plate. Then on one side, cut it ... and starchy foods. See this list of grains and starchy foods . ...

  3. Percutaneous Cryotherapy of Vascular Malformation: Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Cornelis, F., E-mail: francoiscornelis@hotmail.com [Institut Bergonie, Department of Radiology (France); Neuville, A. [Institut Bergonie, Department of Pathology (France); Labreze, C. [Pellegrin Hospital, Department of Pediatric Dermatology (France); Kind, M. [Institut Bergonie, Department of Radiology (France); Bui, B. [Institut Bergonie, Department of Oncology (France); Midy, D. [Pellegrin Hospital, Department of Vascular Surgery (France); Palussiere, J. [Institut Bergonie, Department of Radiology (France); Grenier, N. [Pellegrin Hospital, Department of Radiology (France)

    2013-06-15

    The present report describes a case of percutaneous cryotherapy in a 36-year-old woman with a large and painful pectoral venous malformation. Cryoablation was performed in a single session for this 9-cm mass with 24 h hospitalisation. At 2- and 6-month follow-up, the pain had completely disappeared, and magnetic resonance imaging demonstrated a significant decrease in size. Percutaneous cryoablation shows promise as a feasible and apparently safe method for local control in patients with symptomatic venous vascular malformations.

  4. Percutaneous Cryotherapy of Vascular Malformation: Initial Experience

    International Nuclear Information System (INIS)

    Cornelis, F.; Neuville, A.; Labrèze, C.; Kind, M.; Bui, B.; Midy, D.; Palussière, J.; Grenier, N.

    2013-01-01

    The present report describes a case of percutaneous cryotherapy in a 36-year-old woman with a large and painful pectoral venous malformation. Cryoablation was performed in a single session for this 9-cm mass with 24 h hospitalisation. At 2- and 6-month follow-up, the pain had completely disappeared, and magnetic resonance imaging demonstrated a significant decrease in size. Percutaneous cryoablation shows promise as a feasible and apparently safe method for local control in patients with symptomatic venous vascular malformations.

  5. Percutaneous catheter drainage of pancreatic pseudocysts

    International Nuclear Information System (INIS)

    Karnel, F.; Gebauer, A.; Jantsch, H.; Prayer, L.; Schurawitzki, H.; Feil, W.

    1991-01-01

    The results of CT/US-guided percutaneous drainage in 35 patients with pancreatic pseudocysts are reported. 27 patients recovered without surgery and no further treatment was required. 8 patients required a subsequent surgery due to recurrence. The role of CT/US-guided percutaneous drainage in pancreatic pseudocysts as well as an analysis of the technical aspects associated with a successful procedure are discussed. Although US may be used, we believe CT is safer and allows more precise localisation and guidance in the treatment of pseudocysts. (orig.) [de

  6. Locked modes and magnetic field errors in MST

    International Nuclear Information System (INIS)

    Almagri, A.F.; Assadi, S.; Prager, S.C.; Sarff, J.S.; Kerst, D.W.

    1992-06-01

    In the MST reversed field pinch magnetic oscillations become stationary (locked) in the lab frame as a result of a process involving interactions between the modes, sawteeth, and field errors. Several helical modes become phase locked to each other to form a rotating localized disturbance, the disturbance locks to an impulsive field error generated at a sawtooth crash, the error fields grow monotonically after locking (perhaps due to an unstable interaction between the modes and field error), and over the tens of milliseconds of growth confinement degrades and the discharge eventually terminates. Field error control has been partially successful in eliminating locking

  7. Towards stacked zone plates

    International Nuclear Information System (INIS)

    Werner, S; Rehbein, S; Guttman, P; Heim, S; Schneider, G

    2009-01-01

    Fresnel zone plates are the key optical elements for soft and hard x-ray microscopy. For short exposure times and minimum radiation load of the specimen the diffraction efficiency of the zone plate objectives has to be maximized. As the efficiency strongly depends on the height of the diffracting zone structures the achievable aspect ratio of the nanostructures determines these limits. To reach aspect ratios ≥ 20:1 for high efficient optics we propose to superimpose zone plates on top of each other. With this multiplication approach the final aspect ratio is only limited by the number of stacked zone plate layers. For the stack process several nanostructuring process steps have to be developed and/or improved. Our results show for the first time two layers of zone plates stacked on top of each other.

  8. Plate Motion and Crustal Deformation Estimated with Geodetic Data from the Global Positioning System

    Science.gov (United States)

    Argus, Donald F.; Heflin, Michael B.

    1995-01-01

    We use geodetic data taken over four years with the Global Positioning System (GPS) to estimate: (1) motion between six major plates and (2) motion relative to these plates of ten sites in plate boundary zones. The degree of consistency between geodetic velocities and rigid plates requires the (one-dimensional) standard errors in horizontal velocities to be approx. 2 mm/yr. Each of the 15 angular velocities describing motion between plate pairs that we estimate with GPS differs insignificantly from the corresponding angular velocity in global plate motion model NUVEL-1A, which averages motion over the past 3 m.y. The motion of the Pacific plate relative to both the Eurasian and North American plates is observed to be faster than predicted by NUVEL-1A, supporting the inference from Very Long B ase- line Interferometry (VLBI) that motion of the Pacific plate has speed up over the past few m.y. The Eurasia-North America pole of rotation is estimated to be north of NUVEL-1A, consistent with the independent hypothesis that the pole has recently migrated northward across northeast Asia to near the Lena River delta. Victoria, which lies above the main thrust at the Cascadia subduction zone, moves relative to the interior of the overriding plate at 30% of the velocity of the subducting plate, reinforcing the conclusion that the thrust there is locked beneath the continental shelf and slope.

  9. A new discrete Kirchhoff-Mindlin element based on Mindlin-Reissner plate theory and assumed shear strain fields. I - An extended DKT element for thick-plate bending analysis. II - An extended DKQ element for thick-plate bending analysis

    Science.gov (United States)

    Katili, Irwan

    1993-06-01

    A new three-node nine-degree-of-freedom triangular plate bending element is proposed which is valid for the analysis of both thick and thin plates. The element, called the discrete Kirchhoff-Mindlin triangle (DKMT), has a proper rank, passes the patch test for thin and thick plates in an arbitrary mesh, and is free of shear locking. As an extension of the DKMT element, a four-node element with 3 degrees of freedom per node is developed. The element, referred to as DKMQ (discrete Kirchhoff-Mindlin quadrilateral) is found to provide good results for both thin and thick plates without any compatibility problems.

  10. Wall locking and multiple nonlinear states of magnetic islands

    International Nuclear Information System (INIS)

    Persson, Mikael; Australian National Univ., Canberra, ACT

    1994-01-01

    The nonlinear evolution of magnetic islands is analysed in configurations with multiple resonant magnetic surfaces. The existence of multiple nonlinear steady states, is discussed. These are shown to be associated with states where the dynamics around the different rational surfaces are coupled or decoupled and in the presence of a wall of finite resistivity may correspond wall-locked or non-wall-locked magnetic islands. For the case of strong wall stabilization the locking is shown to consist of two different phases. During the first phase the locking of the plasma at the different rational surfaces occurs. Only when the outermost resonant magnetic surface has locked to the inner surfaces can the actual wall locking process take place. Consequently, wall locking, of a global mode, involving more than one rational surface, can be prevented by the decoupling of the resonant magnetic surfaces by plasma rotation. Possible implications on tokamak experiments are discussed. (author)

  11. Power spectrum of an injection-locked Josephson oscillator

    International Nuclear Information System (INIS)

    Stancampiano, C.V.; Shapiro, S.

    1975-01-01

    Experiments have shown that a Josephson oscillator, exposed to a weak narrow-band input signal, exhibits behavior characteristic of an injection-locked oscillator. When in lock, Adler's theory of injection locking describes the experimental observations reasonably well. The range of applicability of the theory is extended to the out-of-lock regime where a spectrum of output frequencies is observed. Obtaining the theoretical output power spectrum requires solving a differential equation having the same form as the equation describing the resistively shunted junction model of Stewart and of McCumber. Experimental measurements of the output spectrum of a nearly locked Josephson oscillator are shown to be in reasonable agreement with the theory. Additional results discussed briefly include the observation of a frequency dependence of the locked Josephson oscillator output and experiments in which a Josephson oscillator-mixer was injection locked by a weak signal at the rf

  12. WATER TRAPPING ON TIDALLY LOCKED TERRESTRIAL PLANETS REQUIRES SPECIAL CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jun; Abbot, Dorian S. [Department of Geophysical Sciences, University of Chicago, Chicago, IL 60637 (United States); Liu, Yonggang [Woodrow Wilson School of Public and International Affairs, Princeton University, Princeton, NJ 08544 (United States); Hu, Yongyun, E-mail: junyang28@uchicago.edu [Laboratory for Climate and Atmosphere-Ocean Studies, Department of Atmospheric and Oceanic Sciences, School of Physics, Peking University, Beijing (China)

    2014-12-01

    Surface liquid water is essential for standard planetary habitability. Calculations of atmospheric circulation on tidally locked planets around M stars suggest that this peculiar orbital configuration lends itself to the trapping of large amounts of water in kilometers-thick ice on the night side, potentially removing all liquid water from the day side where photosynthesis is possible. We study this problem using a global climate model including coupled atmosphere, ocean, land, and sea ice components as well as a continental ice sheet model driven by the climate model output. For a waterworld, we find that surface winds transport sea ice toward the day side and the ocean carries heat toward the night side. As a result, nightside sea ice remains O(10 m) thick and nightside water trapping is insignificant. If a planet has large continents on its night side, they can grow ice sheets O(1000 m) thick if the geothermal heat flux is similar to Earth's or smaller. Planets with a water complement similar to Earth's would therefore experience a large decrease in sea level when plate tectonics drives their continents onto the night side, but would not experience complete dayside dessiccation. Only planets with a geothermal heat flux lower than Earth's, much of their surface covered by continents, and a surface water reservoir O(10%) of Earth's would be susceptible to complete water trapping.

  13. Self-actuating and locking control for nuclear reactor

    International Nuclear Information System (INIS)

    Chung, D.K.

    1982-01-01

    A self-actuating, self-locking flow cutoff valve particularly suited for use in a nuclear reactor of the type which utilizes a plurality of fluid support neutron absorber elements to provide for the safe shutdown of the reactor. The valve comprises a substantially vertical elongated housing and an aperture plate located in the housing for the flow of fluid therethrough, a substantially vertical elongated nozzle member located in the housing and affixed to the housing with an opening in the bottom for receiving fluid and apertures adjacent a top end for discharging fluid. The nozzle further includes two sealing means, one located above and the other below the apertures. Also located in the housing and having walls surrounding the nozzle is a flow cutoff sleeve having a fluid opening adjacent an upper end of the sleeve, the sleeve being moveable between an upper open position wherein the nozzle apertures are substantially unobstructed and a closed position wherein the sleeve and nozzle sealing surfaces are mated such that the flow of fluid through the apertures is obstructed. It is a particular feature of the present invention that the valve further includes a means for utilizing any increase in fluid pressure to maintain the cutoff sleeve in a closed position. It is another feature of the invention that there is provided a means for automatically closing the valve whenever the flow of fluid drops below a predetermined level

  14. Three Alternative Symbol-Lock Detectors

    Science.gov (United States)

    Shihabi, Mazen M.; Hinedi, Sami M.; Shah, Biren N.

    1993-01-01

    Three symbol-lock detectors proposed as alternatives in advanced receivers processing non-return-to-zero binary data signals. Two perform operations similar to those of older square-law and absolute-value types. However, integrals computed during nonoverlapping symbol periods and, therefore, only one integrator needed in each such detector. Proposed detectors simpler, but performances worse because noises in overlapping samples correlated, whereas noises in nonoverlapping samples not correlated. Third detector is signal-power-estimator type. Signal integrated during successive half symbol cycles, and therefore only one integrator needed. Half-cycle integrals multiplied to eliminate effect of symbol polarity, and products accumulated during M-cycle observation period to smooth out estimate of signal power. If estimated signal power exceeds threshold, delta, then lock declared.

  15. Traumatic knee extension deficit (the locked knee)

    DEFF Research Database (Denmark)

    Helmark, I C; Neergaard, K; Krogsgaard, M R

    2007-01-01

    In the present study we investigated the validity of magnetic resonance imaging (MRI) and arthroscopy in knees with acute, traumatic extension deficit (the "locked knee"), and evaluated whether arthroscopy of knees with no mechanical pathology could be avoided by MRI evaluation. The study consisted...... of 50 patients who had an acute, traumatic extension deficit of the knee. All patients were submitted to MRI prior to arthroscopy. Following MRI and surgery, standardized forms were filled out, attempting to objectify the findings. The orthopaedic surgeon was not aware of the MRI result prior to surgery....... Evaluating MRI, all grade-3 meniscal lesions were considered able to cause a mechanical block as well as acute partial or total anterior cruciate ligament (ACL)-ruptures. ACL-ruptures with an old appearance were not considered able to cause locking. Assuming that arthroscopy was the gold standard...

  16. Mode-locking via dissipative Faraday instability.

    Science.gov (United States)

    Tarasov, Nikita; Perego, Auro M; Churkin, Dmitry V; Staliunas, Kestutis; Turitsyn, Sergei K

    2016-08-09

    Emergence of coherent structures and patterns at the nonlinear stage of modulation instability of a uniform state is an inherent feature of many biological, physical and engineering systems. There are several well-studied classical modulation instabilities, such as Benjamin-Feir, Turing and Faraday instability, which play a critical role in the self-organization of energy and matter in non-equilibrium physical, chemical and biological systems. Here we experimentally demonstrate the dissipative Faraday instability induced by spatially periodic zig-zag modulation of a dissipative parameter of the system-spectrally dependent losses-achieving generation of temporal patterns and high-harmonic mode-locking in a fibre laser. We demonstrate features of this instability that distinguish it from both the Benjamin-Feir and the purely dispersive Faraday instability. Our results open the possibilities for new designs of mode-locked lasers and can be extended to other fields of physics and engineering.

  17. Quantum locking of mirrors in interferometers.

    Science.gov (United States)

    Courty, Jean-Michel; Heidmann, Antoine; Pinard, Michel

    2003-02-28

    We show that quantum noise in very sensitive interferometric measurements such as gravitational-wave detectors can be drastically modified by quantum feedback. We present a new scheme based on active control to lock the motion of a mirror to a reference mirror at the quantum level. This simple technique allows one to reduce quantum effects of radiation pressure and to greatly enhance the sensitivity of the detection.

  18. Dither Cavity Length Controller with Iodine Locking

    Directory of Open Access Journals (Sweden)

    Lawson Marty

    2016-01-01

    Full Text Available A cavity length controller for a seeded Q-switched frequency doubled Nd:YAG laser is constructed. The cavity length controller uses a piezo-mirror dither voltage to find the optimum length for the seeded cavity. The piezo-mirror dither also dithers the optical frequency of the output pulse. [1]. This dither in optical frequency is then used to lock to an Iodine absorption line.

  19. Ultrasound Guided Percutaneous Nephrostomy: Experience at ...

    African Journals Online (AJOL)

    Background: Obstructive uropathy is a common problem in urologic practice; temporary relief of obstruction in the upper tract poses a significant challenge. Ultrasound‑guided percutaneous nephrostomy (PCN) is an option for upper tract drainage; compared to fluoroscopic guidance, it is readily available, affordable, and not ...

  20. Percutaneous Tracheostomy in the Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Fatma Yıldırım

    2015-12-01

    Full Text Available Percutaneous tracheostomy (PT has become an oftenly used procedure in critically ill patients requiring prolonged mechanical ventilation in recent years. The ideal timing and techniques of PT have been topics of considerable debate. In this review, we address general issues regarding PT (indications, contraindications, timing, preparation, techniques, complications and specifically review the literatures regarding the comparison of techniques.

  1. How well tolerated is supine percutaneous nephrolithotomy?

    NARCIS (Netherlands)

    Baard, Joyce; Kamphuis, Guido M.; Westendarp, Matias; de La Rosette, Jean J. M. C. H.

    2014-01-01

    Supine percutaneous nephrolithotomy (PCNL) has been described in 1988 and several modifications followed since. Despite claimed benefits, supine PCNL is still neglected by the majority of urologists. Lack of experience and the fear of complications are possible explanations for the resistance to

  2. Percutaneous Injuries in Nigerian Dentists | Utomi | Nigerian ...

    African Journals Online (AJOL)

    Objective: The purpose of this study is to assess the frequency of percutaneous injuries among Nigerian dentists and to describe the factors associated with the injuries. Materials and Methods: A questionnaire survey of 160 practicing dentists in Lagos, Ibadan, Ife and Benin. Result: A total of 208 injuries were reported by ...

  3. The effect of volatility on percutaneous absorption.

    Science.gov (United States)

    Rouse, Nicole C; Maibach, Howard I

    2016-01-01

    Topically applied chemicals may volatilize, or evaporate, from skin leaving behind a chemical residue with new percutaneous absorptive capabilities. Understanding volatilization of topical medications, such as sunscreens, fragrances, insect repellants, cosmetics and other commonly applied topicals may have implications for their safety and efficacy. A systematic review of English language articles from 1979 to 2014 was performed using key search terms. Articles were evaluated to assess the relationship between volatility and percutaneous absorption. A total of 12 articles were selected and reviewed. Key findings were that absorption is enhanced when coupled with a volatile substance, occlusion prevents evaporation and increases absorption, high ventilation increases volatilization and reduces absorption, and pH of skin has an affect on a chemical's volatility. The articles also brought to light that different methods may have an affect on volatility: different body regions; in vivo vs. in vitro; human vs. Data suggest that volatility is crucial for determining safety and efficacy of cutaneous exposures and therapies. Few articles have been documented reporting evaporation in the context of percutaneous absorption, and of those published, great variability exists in methods. Further investigation of volatility is needed to properly evaluate its role in percutaneous absorption.

  4. ORIGINAL PAPER ORIG ORIG Percutaneous stone removal

    African Journals Online (AJOL)

    Percutaneous nephrolithotomy (PCNL) is an effective procedure to treat patients with complex renal stones,. e.g. staghorn calculi and stones greater than 20 mm in diameter. The treatment of choice for small, less com- plex renal stones is extracorporeal shock-wave litho- tripsy (ESWL).1 We have treated renal stones mainly.

  5. Percutaneous penetration studies for risk assessment

    DEFF Research Database (Denmark)

    Sartorelli, Vittorio; Andersen, Helle Raun; Angerer, Jürgen

    2000-01-01

    experiences, literature data and guidelines already in existence. During the meetings of Percutaneous Penetration Subgroup they presented a number of short papers of up to date information on the key issues. The objective was to focus the existing knowledge and the gaps in the knowledge in the field...

  6. Anisotropic elastic plates

    CERN Document Server

    Hwu, Chyanbin

    2010-01-01

    As structural elements, anisotropic elastic plates find wide applications in modern technology. The plates here are considered to be subjected to not only in plane load but also transverse load. In other words, both plane and plate bending problems as well as the stretching-bending coupling problems are all explained in this book. In addition to the introduction of the theory of anisotropic elasticity, several important subjects have are discussed in this book such as interfaces, cracks, holes, inclusions, contact problems, piezoelectric materials, thermoelastic problems and boundary element a

  7. High loading uranium plate

    International Nuclear Information System (INIS)

    Wiencek, T.C.; Domagala, R.F.; Thresh, H.R.

    1990-01-01

    Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pari of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat hiving a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process

  8. Programmable Self-Locking Origami Mechanical Metamaterials.

    Science.gov (United States)

    Fang, Hongbin; Chu, Shih-Cheng A; Xia, Yutong; Wang, Kon-Well

    2018-04-01

    Developing mechanical metamaterials with programmable properties is an emerging topic receiving wide attention. While the programmability mainly originates from structural multistability in previously designed metamaterials, here it is shown that nonflat-foldable origami provides a new platform to achieve programmability via its intrinsic self-locking and reconfiguration capabilities. Working with the single-collinear degree-4 vertex origami tessellation, it is found that each unit cell can self-lock at a nonflat configuration and, therefore, possesses wide design space to program its foldability and relative density. Experiments and numerical analyses are combined to demonstrate that by switching the deformation modes of the constituent cell from prelocking folding to postlocking pressing, its stiffness experiences a sudden jump, implying a limiting-stopper effect. Such a stiffness jump is generalized to a multisegment piecewise stiffness profile in a multilayer model. Furthermore, it is revealed that via strategically switching the constituent cells' deformation modes through passive or active means, the n-layer metamaterial's stiffness is controllable among 2 n target stiffness values. Additionally, the piecewise stiffness can also trigger bistable responses dynamically under harmonic excitations, highlighting the metamaterial's rich dynamic performance. These unique characteristics of self-locking origami present new paths for creating programmable mechanical metamaterials with in situ controllable mechanical properties. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Total Percutaneous Aortic Repair: Midterm Outcomes

    International Nuclear Information System (INIS)

    Bent, Clare L.; Fotiadis, Nikolas; Renfrew, Ian; Walsh, Michael; Brohi, Karim; Kyriakides, Constantinos; Matson, Matthew

    2009-01-01

    The purpose of this study was to examine the immediate and midterm outcomes of percutaneous endovascular repair of thoracic and abdominal aortic pathology. Between December 2003 and June 2005, 21 patients (mean age: 60.4 ± 17.1 years; 15 males, 6 females) underwent endovascular stent-graft insertion for thoracic (n = 13) or abdominal aortic (n = 8) pathology. Preprocedural computed tomographic angiography (CTA) was performed to assess the suitability of aorto-iliac and common femoral artery (CFA) anatomy, including the degree of CFA calcification, for total percutaneous aortic stent-graft repair. Percutaneous access was used for the introduction of 18- to 26-Fr delivery devices. A 'preclose' closure technique using two Perclose suture devices (Perclose A-T; Abbott Vascular) was used in all cases. Data were prospectively collected. Each CFA puncture site was assessed via clinical examination and CTA at 1, 6, and 12 months, followed by annual review thereafter. Minimum follow-up was 36 months. Outcome measures evaluated were rates of technical success, conversion to open surgical repair, complications, and late incidence of arterial stenosis at the site of Perclose suture deployment. A total of 58 Perclose devices were used to close 29 femoral arteriotomies. Outer diameters of stent-graft delivery devices used were 18 Fr (n = 5), 20 Fr (n = 3), 22 Fr (n = 4), 24 Fr (n = 15), and 26 Fr (n = 2). Percutaneous closure was successful in 96.6% (28/29) of arteriotomies. Conversion to surgical repair was required at one access site (3.4%). Mean follow-up was 50 ± 8 months. No late complications were observed. By CT criteria, no patient developed a >50% reduction in CFA caliber at the site of Perclose deployment during the study period. In conclusion, percutaneous aortic stent-graft insertion can be safely performed, with a low risk of both immediate and midterm access-related complications.

  10. Self-locking degree-4 vertex origami structures.

    Science.gov (United States)

    Fang, Hongbin; Li, Suyi; Wang, K W

    2016-11-01

    A generic degree-4 vertex (4-vertex) origami possesses one continuous degree-of-freedom for rigid folding, and this folding process can be stopped when two of its facets bind together. Such facet-binding will induce self-locking so that the overall structure stays at a pre-specified configuration without additional locking elements or actuators. Self-locking offers many promising properties, such as programmable deformation ranges and piecewise stiffness jumps, that could significantly advance many adaptive structural systems. However, despite its excellent potential, the origami self-locking features have not been well studied, understood, and used. To advance the state of the art, this research conducts a comprehensive investigation on the principles of achieving and harnessing self-locking in 4-vertex origami structures. Especially, for the first time, this study expands the 4-vertex structure construction from single-component to dual-component designs and investigates their self-locking behaviours. By exploiting various tessellation designs, this research discovers that the dual-component designs offer the origami structures with extraordinary attributes that the single-component structures do not have, which include the existence of flat-folded locking planes, programmable locking points and deformability. Finally, proof-of-concept experiments investigate how self-locking can effectively induce piecewise stiffness jumps. The results of this research provide new scientific knowledge and a systematic framework for the design, analysis and utilization of self-locking origami structures for many potential engineering applications.

  11. Dynamic Analysis of Thick Plates Including Deep Beams on Elastic Foundations Using Modified Vlasov Model

    Directory of Open Access Journals (Sweden)

    Korhan Ozgan

    2013-01-01

    Full Text Available Dynamic analysis of foundation plate-beam systems with transverse shear deformation is presented using modified Vlasov foundation model. Finite element formulation of the problem is derived by using an 8-node (PBQ8 finite element based on Mindlin plate theory for the plate and a 2-node Hughes element based on Timoshenko beam theory for the beam. Selective reduced integration technique is used to avoid shear locking problem for the evaluation of the stiffness matrices for both the elements. The effect of beam thickness, the aspect ratio of the plate and subsoil depth on the response of plate-beam-soil system is analyzed. Numerical examples show that the displacement, bending moments and shear forces are changed significantly by adding the beams.

  12. Heat insulating plates

    Energy Technology Data Exchange (ETDEWEB)

    Allan, J.A.F.

    1976-10-28

    Micro-porous insulation plates are dealt with, for example, how they are used in the insulation of heat storage devices. Since one side of such plates is exposed to a temperature of over 700/sup 0/C, a shrinkage of the glass texture of the covering can occur, which can exceed the shrinkage of the inner micro-porous material, so that cracks and splits in the high temperature side of the covering can come about. The task of the invention is to design the plate in such a way as to prevent this from happening. For this purpose the plate is provided, according to invention specifications, with flutes, waves, ribs, waffle or grid patterns and the covering is set into the recesses originating from this.

  13. Create Your Plate

    Medline Plus

    Full Text Available ... Plate is a simple and effective way to manage your blood glucose levels and lose weight. With ... been easier. It can be a challenge to manage portion control wherever you are. Now, our best- ...

  14. Create Your Plate

    Medline Plus

    Full Text Available ... Food Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods donate en -- A Future Without Diabetes - a- ...

  15. Create Your Plate

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ...

  16. Create Your Plate

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... Children and Type 2 Diabetes Know Your Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  18. Create Your Plate

    Medline Plus

    Full Text Available ... diabetes. Other Ways to Give Become a Member Vehicle Donation Planned Giving Options Memorial Giving Brochures & Envelopes ... to manage your blood glucose levels and lose weight. With this method, you fill your plate with ...

  19. Create Your Plate

    Medline Plus

    Full Text Available ... breast cancer and AIDS combined. Your gift today will help us get closer to curing diabetes and ... on one side, cut it again so you will have three sections on your plate. Fill the ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning ... serving of dairy or both as your meal plan allows. Choose healthy fats in small amounts. For ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  2. Create Your Plate

    Medline Plus

    Full Text Available ... these seven steps to get started: Using your dinner plate, put a line down the middle of ... Fitness Food Recipes Planning Meals What Can I Eat Weight Loss Fitness In My Community Calendar of ...

  3. Create Your Plate

    Medline Plus

    Full Text Available ... Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart-Healthy Foods Holiday Meal ...

  4. Create Your Plate

    Medline Plus

    Full Text Available ... for Association Events Messaging Tools Recruiting Advocates Local Market Planning Training Webinars News & Events Advocacy News Call ... Meals > Create Your Plate Share: Print Page Text Size: A A A Listen En Español Create Your ...

  5. Create Your Plate

    Medline Plus

    Full Text Available ... Us in the Fight for a Cure Your tax-deductible gift today can fund critical diabetes research ... Close www.diabetes.org > Food and Fitness > Food > Planning Meals > Create Your Plate Share: Print Page Text ...

  6. Create Your Plate

    Medline Plus

    Full Text Available ... critical diabetes research and support vital diabetes education services that improve the lives of those with diabetes. $50 $100 $250 $500 Other Other Ways ... Meals > Create Your Plate ...

  7. Create Your Plate

    Medline Plus

    Full Text Available ... 800-342-2383) Give by Mail Close ... your plate with more non-starchy veggies and smaller portions of starchy foods and protein—no special tools or counting required! You can ...

  8. Humvee Armor Plate Drilling

    National Research Council Canada - National Science Library

    2004-01-01

    When drilling holes in hard steel plate used in up-armor kits for Humvee light trucks, the Anniston Army Depot, Anniston, Alabama, requested the assistance of the National Center for Defense Manufacturing and Machining (NCDMM...

  9. Create Your Plate

    Medline Plus

    Full Text Available ... Easy Advocacy Checklists for Association Events Messaging Tools Recruiting Advocates Local Market Planning Training Webinars News & Events ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  10. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... Complications Health Insurance For Parents & Kids Know Your Rights We Can Help Enroll in the Living WIth ...

  11. Create Your Plate

    Medline Plus

    Full Text Available ... blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ... today and help fund grants supporting next generation scientists. Donate Today We Can Help - we-can-help. ...

  12. BAO Plate Archive Project

    Science.gov (United States)

    Mickaelian, A. M.; Gigoyan, K. S.; Gyulzadyan, M. V.; Paronyan, G. M.; Abrahamyan, H. V.; Andreasyan, H. R.; Azatyan, N. M.; Kostandyan, G. R.; Samsonyan, A. L.; Mikayelyan, G. A.; Farmanyan, S. V.; Harutyunyan, V. L.

    2017-12-01

    We present the Byurakan Astrophysical Observatory (BAO) Plate Archive Project that is aimed at digitization, extraction and analysis of archival data and building an electronic database and interactive sky map. BAO Plate Archive consists of 37,500 photographic plates and films, obtained with 2.6m telescope, 1m and 0.5m Schmidt telescopes and other smaller ones during 1947-1991. The famous Markarian Survey (or the First Byurakan Survey, FBS) 2000 plates were digitized in 2002-2005 and the Digitized FBS (DFBS, www.aras.am/Dfbs/dfbs.html) was created. New science projects have been conducted based on this low-dispersion spectroscopic material. Several other smaller digitization projects have been carried out as well, such as part of Second Byurakan Survey (SBS) plates, photographic chain plates in Coma, where the blazar ON 231 is located and 2.6m film spectra of FBS Blue Stellar Objects. However, most of the plates and films are not digitized. In 2015, we have started a project on the whole BAO Plate Archive digitization, creation of electronic database and its scientific usage. Armenian Virtual Observatory (ArVO, www.aras.am/Arvo/arvo.htm) database will accommodate all new data. The project runs in collaboration with the Armenian Institute of Informatics and Automation Problems (IIAP) and will continues during 4 years in 2015-2018. The final result will be an Electronic Database and online Interactive Sky map to be used for further research projects. ArVO will provide all standards and tools for efficient usage of the scientific output and its integration in international databases.

  13. Neutron imaging plates

    International Nuclear Information System (INIS)

    Niimura, Nobuo

    1995-01-01

    Imaging plates have been used in the field of medical diagnosis since long ago, but their usefulness was verified as the two-dimensional detector for analyzing the X-ray crystalline structure of high bio molecules like protein, and they have contributed to the remarkable progress in this field. The great contribution is due to the excellent features, such as the detection efficiency of about 100%, the positional resolution smaller than 0.2 mm, the dynamic range of five digits, and the area of several hundreds mm square. The neutron imaging plates have not yet obtained the sufficient results. It was planned to construct the neutron diffractometer for biological matters, and to put imaging plate neutron detectors (IP-ND) to practical use as the detector. The research on the development of IP-NDs was carried out, and the IPp-NDs having the performance comparable with that for X-ray were able to be produced. Imaging plates are the integral type two-dimensional radiation detector using photostimulated luminescence matters, and their principle is explained. As to neutron imaging plates, the converter, neutron detection efficiency and the flight of secondary particles in photo-stimulated luminescence matters are described. As for the present state of development of neutron imaging plates, the IP-NDs made for trial, the dynamic range, the positional resolution, the detection efficiency and the kinds of converters, and the application of IP-NDs are reported. (K.I.)

  14. Posterior Ischemic Optic Neuropathy Following Percutaneous Nephrolithotomy

    Directory of Open Access Journals (Sweden)

    Mohammad Pakravan

    2008-12-01

    Full Text Available

    PURPOSE: To report a case of posterior ischemic optic neuropathy (PION following percutaneous nephrolithotomy (PCNL. CASE REPORT: A 57-year-old man with history of diabetes mellitus, hyperlipidemia and mild anemia underwent PCNL for treatment of nephrolithiasis. He noticed painless visual loss in both eyes immediately after the procedure. Visual acuity was light perception, however ophthalmologic examinations were unremarkable and the optic discs were pink with no swelling. Visual fields were severely affected, but neuro-imaging was normal. Within three months, visual acuity and visual fields improved dramatically but the optic discs became slightly pale. CONCLUSION: This is the first report of PION following PCNL. PION is a rare cause of severe visual loss following surgery. Severe blood loss, hypotension, anemia and body position during surgery are the most important risk factors. Ophthalmologists, urologists and anesthesiologists should be aware of this condition and this rare possibility should be considered prior to surgery.

  1. Complications and functional outcome after fixation of distal tibia fractures with locking plate - A multicentre study

    DEFF Research Database (Denmark)

    Viberg, Bjarke; Kleven, Silje; Hamborg-Petersen, Ellen

    2016-01-01

    as minor and major complications, was retrieved from electronic health records and patient interviews. Long-term functional outcome assessed by EuroQol EQ-5D-5L questionnaire, AOFAS Ankle-Hindfoot scale, and return to pre-injury job function through patient interview and examination. RESULTS: There were 32...... 43A, 5 43B and 34 43C-fractures, 12 open and 10 high-energy fractures. Forty-nine cases (69%) experienced complications during the follow-up time, of which 34 were minor complications and 15 were major complications. Median EQ-5D-5L index value was 0.76, median EQ VAS-score was 80, and median AOFAS...... previously reported....

  2. Locking compression plate osteosynthesis of complicated mandibular fractures in six horses

    OpenAIRE

    Kümmerle, Jan M; Kummer, Martin R; Auer, Jörg A; Nitzl, Dagmar; Fürst, Anton

    2009-01-01

    Complicated mandibular fractures were recognised in one foal, one pony and four horses. The foal was two months old while the adult animals ranged in age from 12 to 24 years. Three horses had a unilateral horizontal ramus fracture. Two fractures were open and one was closed. Comminution was present in one of these patients while lthe other two horses had marked displacement of the fragments. Two suffered from comminuted fractures of the horizontal and vertical ramus of the mandible. One of th...

  3. Cadmium plating replacements

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, M.J.; Groshart, E.C.

    1995-03-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  4. Bending and stretching of plates

    CERN Document Server

    Mansfield, E H; Hemp, W S

    1964-01-01

    The Bending and Stretching of Plates deals with elastic plate theory, particularly on small- and large-deflexion theory. Small-deflexion theory concerns derivation of basic equations, rectangular plates, plates of various shapes, plates whose boundaries are amenable to conformal transformation, plates with variable rigidity, and approximate methods. Large-deflexion theory includes general equations and some exact solutions, approximate methods in large-deflexion theory, asymptotic large-deflexion theories for very thin plates. Asymptotic theories covers membrane theory, tension field theory, a

  5. Progress as Compositional Lock-Freedom

    DEFF Research Database (Denmark)

    Carbone, Marco; Dardha, Ornela; Montesi, Fabrizio

    2014-01-01

    A session-based process satisfies the progress property if its sessions never get stuck when it is executed in an adequate context. Previous work studied how to define progress by introducing the notion of catalysers, execution contexts generated from the type of a process. In this paper, we refine...... such definition to capture a more intuitive notion of context adequacy for checking progress. Interestingly, our new catalysers lead to a novel characterisation of progress in terms of the standard notion of lock-freedom. Guided by this discovery, we also develop a conservative extension of catalysers that does...

  6. Locking classical correlations in quantum States.

    Science.gov (United States)

    DiVincenzo, David P; Horodecki, Michał; Leung, Debbie W; Smolin, John A; Terhal, Barbara M

    2004-02-13

    We show that there exist bipartite quantum states which contain a large locked classical correlation that is unlocked by a disproportionately small amount of classical communication. In particular, there are (2n+1)-qubit states for which a one-bit message doubles the optimal classical mutual information between measurement results on the subsystems, from n/2 bits to n bits. This phenomenon is impossible classically. However, states exhibiting this behavior need not be entangled. We study the range of states exhibiting this phenomenon and bound its magnitude.

  7. Advanced frequency synthesis by phase lock

    CERN Document Server

    Egan, William F

    2011-01-01

    "An addendum to the popular Frequency Synthesis by Phase Lock, 2nd ed, this book describes sigma-delta, a frequency synthesis technique that has gained prominence in recent years. In addition, Simulink will be employed extensively to guide the reader. Fractional-n, the still-used forerunner to sigma-delta, is also discussed. Sequences of simulated results allow the reader to gain a deeper understanding while detailed appendices provide information from various stages of development. Simulation models discussed in the chapters that are available online."--Provided by publisher.

  8. Saint Lawrence Seaway Additional Locks Study. Appendices.

    Science.gov (United States)

    1982-07-01

    1790320 1945 2370 27000 LO 710 i...l.I27.121.710.0443 23.00.769 12.229.146 2,3231.503 2.5~06.000 2.239.100 23.760.400 23.019.2002 3.413200 P.. Capita...1955. - ,. XISING EISENHOWER LOCK G ISO Se-s SP*c.--2 2, 13 TIL ANDBDROC ~~~~~~ AREA LIISO9TL AD All b 22 CORPS OF ENGINEERS BUFFAL0 NY RUFFALO DISTR

  9. Biomechanical evaluation of a new MatrixMandible plating system on cadaver mandibles.

    Science.gov (United States)

    Gateno, Jaime; Cookston, Christopher; Hsu, Sam Sheng-Pin; Stal, Drew N; Durrani, Salim K; Gold, Jonathan; Ismaily, Sabir; Alexander, Jerry W; Noble, Philip C; Xia, James J

    2013-11-01

    Current mandibular plating systems contain a wide range of plates and screws needed for the treatment of mandibular reconstruction and mandibular fractures. The authors' hypothesis was that a single diameter screw could be used in all applications in a plating system. Therefore, the purpose of this study was to test if the 2.0-mm locking screws could replace the 2.4-mm screws to stabilize a 2.5-mm-thick reconstruction plate in the treatment of mandibular discontinuity. Thirty-six fresh human cadaveric mandibles were used: 18 were plated using 2.0-mm locking screws (experimental) and the other 18 were plated using 2.4-mm locking screws (control). Each group was further divided into 3 subgroups based on the site of loading application: the ipsilateral (right) second premolar region, the central incisal region, and the contralateral (left) first molar region. The same ipsilateral (right) mandibular angular discontinuity was created by the same surgeon. The mandible was mounted on a material testing machine. The micromotions between the 2 segments, permanent and elastic displacements, were recorded after incremental ramping loads. The magnitude of screw back-out and the separation between plate and bone were recorded using a laser scanner (resolution, 0.12 mm) before and after the loading applications. The data were processed. Descriptive analyses and a general linear model for repeated measures analysis of variance were performed. There was no statistically significant difference in permanent displacement (mean, 1.16 and 0.82 mm, respectively) between the 2.0-mm and 2.4-mm screw groups. There also was no statistically significant difference in elastic displacement between the 2 groups (mean, 1.48 and 1.21 mm, respectively). Finally, there were no statistically significant differences in screw back-out or separation between plate and bone between the 2 groups. All means for screw back-out and separation between screw and bone for each group were judged within the

  10. Short locking time and low jitter phase-locked loop based on slope charge pump control

    International Nuclear Information System (INIS)

    Guo Zhongjie; Liu Youbao; Wu Longsheng; Wang Xihu; Tang Wei

    2010-01-01

    A novel structure of a phase-locked loop (PLL) characterized by a short locking time and low jitter is presented, which is realized by generating a linear slope charge pump current dependent on monitoring the output of the phase frequency detector (PFD) to implement adaptive bandwidth control. This improved PLL is created by utilizing a fast start-up circuit and a slope current control on a conventional charge pump PLL. First, the fast start-up circuit is enabled to achieve fast pre-charging to the loop filter. Then, when the output pulse of the PFD is larger than a minimum value, the charge pump current is increased linearly by the slope current control to ensure a shorter locking time and a lower jitter. Additionally, temperature variation is attenuated with the temperature compensation in the charge pump current design. The proposed PLL has been fabricated in a kind of DSP chip based on a 0.35 μm CMOS process. Comparing the characteristics with the classical PLL, the proposed PLL shows that it can reduce the locking time by 60% with a low peak-to-peak jitter of 0.3% at a wide operation temperature range. (semiconductor integrated circuits)

  11. Low-power wide-locking-range injection-locked frequency divider for OFDM UWB systems

    Energy Technology Data Exchange (ETDEWEB)

    Yin Jiangwei; Li Ning; Zheng Renliang; Li Wei; Ren Junyan, E-mail: lining@fudan.edu.c [State Key Laboratory of ASIC and System, Fudan University, Shanghai 201203 (China)

    2009-05-01

    This paper describes a divide-by-two injection-locked frequency divider (ILFD) for frequency synthesizers as used in multiband orthogonal frequency division multiplexing (OFDM) ultra-wideband (UWB) systems. By means of dual-injection technique and other conventional tuning techniques, such as DCCA and varactor tuning, the divider demonstrates a wide locking range while consuming much less power. The chip was fabricated in the Jazz 0.18 mum RF CMOS process. The measurement results show that the divider achieves a locking range of 4.85 GHz (6.23 to 11.08 GHz) at an input power of 8 dBm. The core circuit without the test buffer consumes only 3.7 mA from a 1.8 V power supply and has a die area of 0.38 x 0.28 mm{sup 2}. The wide locking range combined with low power consumption makes the ILFD suitable for its application in UWB systems.

  12. Low-power wide-locking-range injection-locked frequency divider for OFDM UWB systems

    International Nuclear Information System (INIS)

    Yin Jiangwei; Li Ning; Zheng Renliang; Li Wei; Ren Junyan

    2009-01-01

    This paper describes a divide-by-two injection-locked frequency divider (ILFD) for frequency synthesizers as used in multiband orthogonal frequency division multiplexing (OFDM) ultra-wideband (UWB) systems. By means of dual-injection technique and other conventional tuning techniques, such as DCCA and varactor tuning, the divider demonstrates a wide locking range while consuming much less power. The chip was fabricated in the Jazz 0.18 μm RF CMOS process. The measurement results show that the divider achieves a locking range of 4.85 GHz (6.23 to 11.08 GHz) at an input power of 8 dBm. The core circuit without the test buffer consumes only 3.7 mA from a 1.8 V power supply and has a die area of 0.38 x 0.28 mm 2 . The wide locking range combined with low power consumption makes the ILFD suitable for its application in UWB systems.

  13. Arterial Complications of Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    L'Hermine, Claude; Ernst, Olivier; Delemazure, Olivier; Sergent, Geraldine

    1996-01-01

    Purpose: To report on the frequency and treatment of arterial complications due to percutaneous transhepatic biliary drainage (PTBD).Materials: Lesions of the intrahepatic artery were encountered in 10 of 525 patients treated by PTBD (2%). Hemobilia followed in 9 patients and subcapsular hematoma in 1. Seven patients had a benign biliary stenosis and 3 had a malignant stenosis.Results: The bleeding resolved spontaneously in 3 patients. In 7 it required arterial embolization, which was successfully achieved either through the percutaneous catheter (n= 3) or by arteriography (n= 4).Conclusion: Arterial bleeding is a relatively rare complication of PTBD that can easily be treated by selective arterial embolization when it does not resolve spontaneously. In this series its frequency was much higher (16%) when the stenosis was benign than when it was malignant (0.6%)

  14. Percutaneous Cementoplasty for Kienbock’s Disease

    Energy Technology Data Exchange (ETDEWEB)

    Vallejo, Eduardo Crespo, E-mail: dreduardocrespo@gmail.com [Hospital Príncipe de Asturias, Vascular and Interventional Radiology Unit (Spain); Martinez-Galdámez, Mario [Fundación Jimenez Diaz, Neurointerventional Radiology Unit (Spain); Martin, Ernesto Santos [Memorial Sloan-Kettering Center, Vascular and Interventional Radiology Unit (United States); Gregorio, Arturo Perera de [Hospital Príncipe de Asturias, Department of Orthopedic Surgery (Spain); Gallego, Miriam Gamo [Hospital Príncipe de Asturias, Vascular and Interventional Radiology Unit (Spain); Escobar, Angeles Ramirez [Hospital Príncipe de Asturias, Radiology Unit (Spain)

    2017-05-15

    Kienböck disease typically presents with wrist pain, swelling, restricted range of motion, and difficulty in performing activities of daily living. Because the etiology and evolution of disease remain unclear, broad ranges of treatments have been designed. Percutaneous cementoplasty is expanding its role for managing painful bone metastases outside the spine. We can draw a parallel between lytic tumoral lesions and Kienbock’s disease. Increasing the strength and rigidity of lunate with cementoplasty can prevent it from collapse, relieve the symptoms associated with the process of avascular necrosis, and increase the wrist range of motion. We report the case of 30-year-old man with a painful stage IIIA Kienböck disease who underwent percutaneous cementoplasty and experienced immediate effective pain relief and recovery of wrist mobility.

  15. Percutaneous Cementoplasty for Kienbock’s Disease

    International Nuclear Information System (INIS)

    Vallejo, Eduardo Crespo; Martinez-Galdámez, Mario; Martin, Ernesto Santos; Gregorio, Arturo Perera de; Gallego, Miriam Gamo; Escobar, Angeles Ramirez

    2017-01-01

    Kienböck disease typically presents with wrist pain, swelling, restricted range of motion, and difficulty in performing activities of daily living. Because the etiology and evolution of disease remain unclear, broad ranges of treatments have been designed. Percutaneous cementoplasty is expanding its role for managing painful bone metastases outside the spine. We can draw a parallel between lytic tumoral lesions and Kienbock’s disease. Increasing the strength and rigidity of lunate with cementoplasty can prevent it from collapse, relieve the symptoms associated with the process of avascular necrosis, and increase the wrist range of motion. We report the case of 30-year-old man with a painful stage IIIA Kienböck disease who underwent percutaneous cementoplasty and experienced immediate effective pain relief and recovery of wrist mobility.

  16. Percutaneous drainage of 100 subphrenic abscesses

    International Nuclear Information System (INIS)

    Casola, G.; Sonnenberg, E. van; D'Agostino, H.; Kothari, R.; May, S.; Taggart, S.

    1990-01-01

    PURPOSE: Percutaneous drainage of subphrenic abscesses is technically more difficult because lung and pleura may be transgressed during catheter insertion. The purpose of this paper is to determine the incidence of thoracic complications secondary to subphrenic abscess drainage and to determine factors that may alter this. The authors' series consists of 100 subphrenic abscesses that were drained percutaneously. Patients range in age from 14 to 75 years. Abscesses were secondary to surgery (splenectomy, pancreatectomy, partial hepatectomy, gastrectomy), pancreatitis, and trauma. Catheters ranged in size from 8 to 14 F and were inserted via trocar or Seldinger technique. Thoracic complications of pneumothorax or empyema were determined from follow-up chest radiographs or CT scans

  17. CIRSE Guidelines on Percutaneous Vertebral Augmentation

    Energy Technology Data Exchange (ETDEWEB)

    Tsoumakidou, Georgia, E-mail: gtsoumakidou@yahoo.com; Too, Chow Wei, E-mail: spyder55@gmail.com; Koch, Guillaume, E-mail: guillaume.koch@gmail.com; Caudrelier, Jean, E-mail: jean.caudrelier@chru-strasbourg.fr; Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juliengarnon@gmail.com; Gangi, Afshin, E-mail: gangi@unistra.fr [Strasbourg University Hospital, Interventional Radiology Department (France)

    2017-03-15

    Vertebral compression fracture (VCF) is an important cause of severe debilitating back pain, adversely affecting quality of life, physical function, psychosocial performance, mental health and survival. Different vertebral augmentation procedures (VAPs) are used in order to consolidate the VCFs, relief pain,and whenever posible achieve vertebral body height restoration. In the present review we give the indications, contraindications, safety profile and outcomes of the existing percutaneous VAPs.

  18. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair with the ...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  19. Neuronavigated percutaneous approach to the sphenopalatine ganglion.

    Science.gov (United States)

    Benedetto, Nicola; Perrini, Paolo

    2017-02-01

    The sphenopalatine ganglion (SPG) has been assumed to be involved in the genesis of several types of facial pain, including Sluder's neuralgia, trigeminal neuralgia, persistent idiopathic facial pain, cluster headache, and atypical facial pain. The gold standard treatments for SPG-related pain are percutaneous procedures performed with the aid of fluoroscopy or CT. In this technical note the authors present, for the first time, an SPG approach using the aid of a neuronavigator.

  20. Percutaneous treatment in patients presenting with malignant cardiac tamponade

    Energy Technology Data Exchange (ETDEWEB)

    Marcy, P.Y. [Antoine Lacassagne Center, Interventional Radiology Department, Nice (France); Bondiau, P.Y. [Antoine Lacassagne Center, Radiation Therapy Department, Nice (France); Brunner, P. [Centre Hospitalier Princesse, Grace (Monaco). Interventional Radiology Department

    2005-09-01

    The percutaneous treatment of pericardial effusion resulting in cardiac tamponade has undergone an evolution in recent years with the use of less invasive drainage techniques in selected cases. To determine optimal therapy modalities for oncology patients with malignant pericardial tamponade (MPT), the authors review their institutional experience with percutaneous needle puncture routes, means of imaging-guided drainage and percutaneous management of the pericardial fluid effusion (pericardial sclerosis and balloon pericardiotomy). Advantages and limits of the percutaneous techniques will be compared to the surgical treatment. (orig.)

  1. Percutaneous Dilatational Tracheostomy via Griggs Technique.

    Science.gov (United States)

    Karimpour, Hasan Ali; Vafaii, Kamran; Chalechale, Maryam; Mohammadi, Saeed; Kaviannezhad, Rasool

    2017-01-01

    Tracheostomy is considered the airway management of choice for patients who need prolonged mechanical ventilation support. Percutaneous Dilatational Tracheotomy (PDT) is a technique that can be performed easily and rapidly at bedside and is particularly useful in the intensive care setting. The Griggs percutaneous tracheotomy is unique in its utilization of a guide wire dilator forceps. We aimed to describe the early perioperative and late postoperative complications of PDT using the Griggs technique in patients in the intensive care unit (ICU). This cross-sectional study was conducted on all patients who underwent tracheostomy in the ICU of the Imam Reza Hospital of Kermanshah, Iran, from June 2011 to June 2015. PDT was performed in 184 patients with the Griggs technique. Demographic variables, as well as perioperative and late postoperative complications were recorded. The mean age of patients was 57.3 ± 15.37 years. The most common primary causes of tracheostomy were hypoxic brain damage disorders (43.2%) and pneumonia (14.8%). Perioperative and early complications occurred in 16.7 % of procedures, of which 9.3% were bleedings (minor, significant and major). Furthermore, the incidence of late complications was 8.6%, including: stomal infection, difficult replace tracheostomy tube, tracheoesophageal fistula, tracheal stenosis, and tracheomalacia. PDT via Griggs technique is a safe, quick, and effective method. The low incidence of complications indicates that bedside percutaneous tracheostomy can be performed safely as a routine procedure for daily care implemented in the ICU.

  2. Imaging in percutaneous ablation for atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Maksimovic, Ruzica [Erasmus Medical Center, Department of Radiology, GD Rotterdam (Netherlands); Institute for Cardiovascular Diseases of the University Medical Center, Belgrade (Czechoslovakia); Dill, Thorsten [Kerckhoff-Heart Center, Department of Cardiology, Bad Nauheim (Germany); Ristic, Arsen D.; Seferovic, Petar M. [Institute for Cardiovascular Diseases of the University Medical Center, Belgrade (Czechoslovakia)

    2006-11-15

    Percutaneous ablation for electrical disconnection of the arrhythmogenic foci using various forms of energy has become a well-established technique for treating atrial fibrillation (AF). Success rate in preventing recurrence of AF episodes is high although associated with a significant incidence of pulmonary vein (PV) stenosis and other rare complications. Clinical workup of AF patients includes imaging before and after ablative treatment using different noninvasive and invasive techniques such as conventional angiography, transoesophageal and intracardiac echocardiography, computed tomography (CT) and magnetic resonance imaging (MRI), which offer different information with variable diagnostic accuracy. Evaluation before percutaneous ablation involves assessment of PVs (PV pattern, branching pattern, orientation and ostial size) to facilitate position and size of catheters and reduce procedure time as well as examining the left atrium (presence of thrombi, dimensions and volumes). Imaging after the percutaneous ablation is important for assessment of overall success of the procedure and revealing potential complications. Therefore, imaging methods enable depiction of PVs and the anatomy of surrounding structures essential for preprocedural management and early detection of PV stenosis and other ablation-related procedures, as well as long-term follow-up of these patients. (orig.)

  3. Imaging in percutaneous ablation for atrial fibrillation

    International Nuclear Information System (INIS)

    Maksimovic, Ruzica; Dill, Thorsten; Ristic, Arsen D.; Seferovic, Petar M.

    2006-01-01

    Percutaneous ablation for electrical disconnection of the arrhythmogenic foci using various forms of energy has become a well-established technique for treating atrial fibrillation (AF). Success rate in preventing recurrence of AF episodes is high although associated with a significant incidence of pulmonary vein (PV) stenosis and other rare complications. Clinical workup of AF patients includes imaging before and after ablative treatment using different noninvasive and invasive techniques such as conventional angiography, transoesophageal and intracardiac echocardiography, computed tomography (CT) and magnetic resonance imaging (MRI), which offer different information with variable diagnostic accuracy. Evaluation before percutaneous ablation involves assessment of PVs (PV pattern, branching pattern, orientation and ostial size) to facilitate position and size of catheters and reduce procedure time as well as examining the left atrium (presence of thrombi, dimensions and volumes). Imaging after the percutaneous ablation is important for assessment of overall success of the procedure and revealing potential complications. Therefore, imaging methods enable depiction of PVs and the anatomy of surrounding structures essential for preprocedural management and early detection of PV stenosis and other ablation-related procedures, as well as long-term follow-up of these patients. (orig.)

  4. Percutaneous catheter drainage of lung abscess

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Shin; Chun, Kyung Ah; Choi, Hyo Sun; Ha, Hyun Kown; Shinn, Kyung Sub [Catholic University Medical college, Seoul (Korea, Republic of)

    1993-09-15

    From March 1987 to July 1989, six patients (five adults and one child) with lung abscess (size, 5-13 cm in diameter) were treated with percutaneous aspiration and drainage. In each case, the puncture was made where the wall of the abscess was in contact with the pleural surface. An 8 to 10 Fr cartheter was inserted for drainage. Five of 6 had a dynamatic clinical response within 24 hours of the drainage. Percutaneous drainage was successful with complete abscess resolution in four and partial resolution in one patient. No response was seen in the rest one. The duration of drainage ranged from 7 to 18 days(average, 15.5 days) in successful cases. One case of the failure in drainage was due tio persistent aspiration of the neurologically impaired patient. In one patient, the abscess resolved after drainage but recurred after inadvertent removal of the catheter 7 days after insertion. In two patients, concurrent pleural empyema was resolved completely by the drainage. Computed tomography provide anatomic details necessary for choosing the puncture site and avoiding a puncture of the lung parenchyma. Percutaneous catheter drainage is safe and effective method for treating patient with lung abscess.

  5. Percutaneous catheter drainage of lung abscess

    International Nuclear Information System (INIS)

    Kim, Young Shin; Chun, Kyung Ah; Choi, Hyo Sun; Ha, Hyun Kown; Shinn, Kyung Sub

    1993-01-01

    From March 1987 to July 1989, six patients (five adults and one child) with lung abscess (size, 5-13 cm in diameter) were treated with percutaneous aspiration and drainage. In each case, the puncture was made where the wall of the abscess was in contact with the pleural surface. An 8 to 10 Fr cartheter was inserted for drainage. Five of 6 had a dynamatic clinical response within 24 hours of the drainage. Percutaneous drainage was successful with complete abscess resolution in four and partial resolution in one patient. No response was seen in the rest one. The duration of drainage ranged from 7 to 18 days(average, 15.5 days) in successful cases. One case of the failure in drainage was due tio persistent aspiration of the neurologically impaired patient. In one patient, the abscess resolved after drainage but recurred after inadvertent removal of the catheter 7 days after insertion. In two patients, concurrent pleural empyema was resolved completely by the drainage. Computed tomography provide anatomic details necessary for choosing the puncture site and avoiding a puncture of the lung parenchyma. Percutaneous catheter drainage is safe and effective method for treating patient with lung abscess

  6. Percutaneous dilatation of biliary benign strictures

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Choi, Byung Ihn; Sung, Kyu Bo; Han, Man Chung; Park, Yong Hyun; Yoon, Yong Bum [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1986-06-15

    Percutaneous biliary dilation was done in 3 patients with benign strictures. The first case was 50-year-old male who had multiple intrahepatic stones with biliary stricture. The second 46-year-old female and the third 25-year-old male suffered from recurrent cholangitis with benign stricture of anastomotic site after choledocho-jejunostomy. In the first case, a 6mm diameter Grunzing dilatation balloon catheter was introduced through the T-tube tract. In the second case, the stricture was dilated with two balloons of 5mm and 8mm in each diameter sequentially through the U-loop tract formed by surgically made jejunostomy and percutaneous transhepatic puncture. In the third case, the dilatation catheter was introduced through the percutaneous transhepatic tract. Dilatation was made with a pressure of 5 to 10 atmospheres for 1 to 3 minutes duration for 3 times. In all 3 cases, the strictures were successfully dilated and in second and third cases internal stent was left across the lesion for prevention of restenosis.

  7. Plating on Zircaloy-2

    International Nuclear Information System (INIS)

    Dini, J.W.; Johnson, H.R.; Jones, A.

    1979-03-01

    Zircaloy-2 is a difficult alloy to coat with an adherent electroplate because it easily forms a tenacious oxide film in air and aqueous solutions. Procedures reported in the literature and those developed at SLL for surmounting this problem were investigated. The best results were obtained when specimens were first etched in either an ammonium bifluoride/sulfuric acid or an ammonium bifluoride solution, plated, and then heated at 700 0 C for 1 hour in a constrained condition. Machining threads in the Zircaloy-2 for the purpose of providing sites for mechanical interlocking of the plating also proved satisfactory

  8. NICKEL PLATING PROCESS

    Science.gov (United States)

    Hoover, T.B.; Zava, T.E.

    1959-05-12

    A simplified process is presented for plating nickel by the vapor decomposition of nickel carbonyl. In a preferred form of the invention a solid surface is nickel plated by subjecting the surface to contact with a mixture containing by volume approximately 20% nickel carbonyl vapor, 2% hydrogen sulfide and .l% water vapor or 1% oxygen and the remainder carbon dioxide at room temperature until the desired thickness of nickel is obtained. The advantage of this composition over others is that the normally explosive nickel carbonyl is greatly stabilized.

  9. Hydrodynamics of a flexible plate between pitching rigid plates

    Science.gov (United States)

    Kim, Junyoung; Kim, Daegyoum

    2017-11-01

    The dynamics of a flexible plate have been studied as a model problem in swimming and flying of animals and fluid-structure interaction of plants and flags. Motivated by fish schooling and an array of sea grasses, we investigate the dynamics of a flexible plate closely placed between two pitching rigid plates. In most studies on passive deformation of the flexible plate, the plate is immersed in a uniform flow or a wavy flow. However, in this study, the flexible plate experiences periodic deformation by the oscillatory flow generated by the prescribed pitching motion of the rigid plates. In our model, the pitching axes of the rigid plates and the clamping position of the flexible plate are aligned on the same line. The flexible plate shows various responses depending on length and pitching frequency of rigid plates, thickness of a flexible plate, and free-stream velocity. To find the effect of each variable on the response of the flexible plate, amplitude of a trailing edge and modal contribution of a flapping motion are compared, and flow structure around the flexible plate is examined.

  10. Fixing a fractured arthrodesed hip with rapid prototype templating and minimal invasive plate osteosynthesis

    Directory of Open Access Journals (Sweden)

    Christian Fang

    2015-12-01

    Full Text Available CASE:: We present an elderly lady with an intertrochanteric fracture of a previously fused hip. A 3D printed model of her pelvis and femur was used for implant templating before surgery. Minimal invasive fixation was performed with a spanning reversed distal femur locking plate without the need for removal of the previous implant. Multiple long locking screws were placed in the supra-acetabular region. The patient had union in 4 months, return to function and no complication. Conclusion:: The technique allowed us to optimize implant selection and insert screws safely at difficult trajectories using minimal invasive surgery. Keywords: Hip fusion, Fracture, Plating, Minimal invasive, 3D printing

  11. Reconfigurable Braille display with phase change locking

    Science.gov (United States)

    Soule, Cody W.; Lazarus, Nathan

    2016-07-01

    Automatically updated signs and displays for sighted people are common in today’s world. However, there is no cheap, low power equivalent available for the blind. This work demonstrates a reconfigurable Braille cell using the solid-to-liquid phase change of a low melting point alloy as a zero holding power locking mechanism. The device is actuated with the alloy in the liquid state, and is then allowed to solidify to lock the Braille dot in the actuated position. A low-cost manufacturing process is developed that includes molding of a rigid silicone to create pneumatic channels, and bonding of a thin membrane of a softer silicone on the surface for actuation. A plug of Field’s metal (melting point 62 °C) is placed in the pneumatic channels below each Braille dot to create the final device. The device is well suited for low duty cycle operation in applications such as signs, and is able to maintain its state indefinitely without additional power input. The display requires a pneumatic pressure of only 24 kPa for actuation, and reconfiguration has been demonstrated in less than a minute and a half.

  12. Operative treatment of intra-articular calcaneal fractures with calcaneal plates and its complications

    Directory of Open Access Journals (Sweden)

    Rak Vaclav

    2009-01-01

    Full Text Available Background: In a retrospective study we analysed intra-articular calcaneal fracture treatment by comparing results and complications related to fracture stabilization with nonlocking calcaneal plates and locking compression plates. Materials and Methods: We performed 76 osteosynthesis (67 patients of intra-articular calcaneal fractures using the standard extended lateral approach from February 2004 to October 2007. Forty-two operations using nonlocking calcaneal plates (group A were performed during the first three years, and 34 calcaneal fractures were stabilized using locking compression plates (group B in 2007. In the Sanders type IV fractures, reconstruction of the calcaneal shape was attempted. Depending on the type of late complication, we performed subtalar arthroscopy in six cases, arthroscopically assisted subtalar distraction bone block arthrodesis in six cases, and plate removal with lateral-wall decompression in five cases. The patients were evaluated by the AOFAS Ankle-Hindfoot Scale. Results: Wound healing complications were 7/42 (17% in group A and 1/34 (3% in group B. No patient had deep osseous infection or foot rebound compartment syndrome. Preoperative size of Bφhler´s angle correlated with postoperative clinical results in both groups. There were no late complications necessitating corrective procedure or arthroscopy until December 2008 in Group B. All late complications ccurred in Group A. The overall results according to the AOFAS Ankle Hindfoot Scale were good or excellent in 23/42 (55% in group A and in 30/34 (85% in group B. Conclusion: Open reduction and internal fixation of intra-articular calcaneal fractures has become a standard surgical method. Fewer complications and better results related to treatment with locking compression plates confirmed in comparison to nonlocking ones were noted for all Sanders types of intra-articular calcaneal fractures. Age and Sanders type IV fractures are not considered to be the

  13. Tom Bevill Upper Lock Approach, Tennessee-Tombigbee Waterway, Alabama: Hydraulic Navigation Investigation

    National Research Council Canada - National Science Library

    Winkler, Michael

    2003-01-01

    .... The lock is connected to the dam with a 150-ft abutment wall. A strong crosscurrent or outdraft existing in and around the upstream lock entrance causes difficulty for tow traffic navigating the lock...

  14. Cardiac implantable electronic device lead extraction using the lead-locking device system: keeping it simple, safe, and inexpensive with mechanical tools and local anesthesia.

    Science.gov (United States)

    Manolis, Antonis S; Georgiopoulos, Georgios; Metaxa, Sofia; Koulouris, Spyridon; Tsiachris, Dimitris

    2017-10-01

    We have previously reported our successful approach for percutaneous cardiac implantable electronic device (CIED) lead extraction using inexpensive tools, which we have continued over the years. Herein we report the results of the systematic use of a unique stylet, the lead-locking device (LLD), which securely locks the entire lead lumen, aided with non-powered telescoping sheaths in 54 patients to extract 98 CIED leads. This prospective observational clinical study included 38 men and 16 women aged 68.9±13.1 years undergoing lead extraction for device infection (n=46), lead malfunction (n=5), or prior to defibrillator implant (n=3). Leads were in place for 6.7±4.3 years. Infections were more commonly due to Staphylococcus species (n=40). There were 78 pacing (31 ventricular, 37 atrial, 4 VDD, and 6 coronary sinus leads) and 20 defibrillating leads. Using simple traction (6 leads) and the LLD stylets (92 leads) aided with telescoping sheaths (15 patients), 96 (98%) leads in 52 (96.3%) patients were successfully removed, with all but one leads removed using a subclavian approach; in 1 patient, the right femoral approach was also required. In 2 patients, distal fragments from one ventricular pacing and one defibrillating lead could not be removed. Finally, lead removal was completely (52/54) (96.3%) or partially (2/54) (3.7%) successful in 54 patients for 96 of 98 leads (98%) without major complications. Percutaneous lead extraction can be successful with mechanical tools using the LLD locking stylet aided with non-powered telescoping sheaths through a simplified, safe, and inexpensive procedure using local anesthesia.

  15. Geodesy cannot presently detect the up-dip limit of frictional locking on megathrusts

    Science.gov (United States)

    Almeida, R. V.; Lindsey, E. O.; Bradley, K.; Hubbard, J.; Sathiakumar, S.; Malick, R.; Hill, E.

    2017-12-01

    Most discussions of interseismic behavior on megathrust faults focus on whether they are frictionally locked or creeping. Unfortunately, many geodetic studies of subduction zone megathrusts equate fault coupling with frictional locking. This comparison is not appropriate, as one reflects the physical properties of the fault, and the other reflects the kinematics of the fault. Much of the uncertainty about slip behavior is because in subduction zones, the shallow part of the fault is far from land, and therefore creep is not detectable by land-based GPS. Published coupling maps of subduction zone megathrusts often assume a low coupling ratio near the trench, updip from fully coupled regions. Yet, if the megathrust attains a coupling ratio of 1 anywhere on the fault (i.e., the hanging wall is moving with the same velocity as the footwall), a lower value of coupling updip of this location requires interseismic extension at a rate proportional to the decrease (Wang and Dixon, 2004). We argue that the shallow region of megathrusts lie in updip stress shadows, and do not (except under rare circumstances) experience appropriate driving forces to cause significant creep during the interseismic period. Therefore it may not be possible to determine whether these regions are frictionally locked by examining interseismic geodetic records. We demonstrate this effect using a boundary element model with rate-strengthening friction and a simplified subduction zone geometry. We show that a coupling value of zero at the trench is physically unrealistic even if only a small portion of the downdip fault zone is locked. The maximum creep at the trench depends on the width of the transition of the frictionally locked zone, but should be small (<30% of plate rate) under most circumstances. During the interseismic period, even if the shallow parts of megathrusts are frictionally unlocked, creep is likely smaller than the resolution of current seafloor geodetic techniques (which is

  16. Create Your Plate

    Medline Plus

    Full Text Available ... meal-planning, . In this section Food Planning Meals Diabetes Meal Plans and a Healthy Diet Create Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods donate en -- A Future Without Diabetes - a-future-without-diabetes-2.html A Future ...

  17. Create Your Plate

    Medline Plus

    Full Text Available ... tool is not to scale because of the differences in types of vegetables. When creating your plate ... function (data) { $('#survey-errors').remove(); $('.survey-form .form-group .survey-alert-wrap').remove(); if (data.submitSurveyResponse.success == ' ...

  18. Create Your Plate

    Medline Plus

    Full Text Available ... Your Plate Meal Planning for Vegetarian Diets Gluten Free Diets Holiday Meal Planning Cook with Heart-Healthy Foods donate en -- A Future Without Diabetes - a-future-without-diabetes-2.html A Future Without Diabetes Donate towards research today and your gift will be matched. Donate ...

  19. Create Your Plate

    Medline Plus

    Full Text Available ... Planning Meals > Create Your Plate Share: Print Page Text Size: A A A Listen En Español Create ... Type 2 Education Series Hear audio clips and full recordings of past Q&A events at your ...

  20. Create Your Plate

    Medline Plus

    Full Text Available ... 1 Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are ... Fitness Home Food MyFoodAdvisor Recipes Association Cookbook Recipes Planning Meals Diabetes Meal Plans Create Your Plate Gluten ...

  1. Create Your Plate

    Medline Plus

    Full Text Available ... tax-deductible gift today can fund critical diabetes research and support vital diabetes education services that improve the ... effective way to manage your blood glucose levels and lose weight. With this method, you fill your plate with more non-starchy ...

  2. Microchannel plate photodetectors

    International Nuclear Information System (INIS)

    Majka, R.

    1977-01-01

    A review is given the status of development work on photodetectors using microchannel plates (MCP) as the electron gain element. Projections are made and opinions are presented on what might be available in the next few years. Several uses for these devices at ISABELLE are mentioned

  3. Parallel plate detectors

    International Nuclear Information System (INIS)

    Gardes, D.; Volkov, P.

    1981-01-01

    A 5x3cm 2 (timing only) and a 15x5cm 2 (timing and position) parallel plate avalanche counters (PPAC) are considered. The theory of operation and timing resolution is given. The measurement set-up and the curves of experimental results illustrate the possibilities of the two counters [fr

  4. Flat plate collector. Solarflachkollektor

    Energy Technology Data Exchange (ETDEWEB)

    Raab, N

    1979-03-29

    The invention refers to a flat solar collector with an absorber plate, which is arranged on a support and is covered by a transparent window, between which and the plate there is an air space. The previously known structures of this type had the disadvantage that the thermal expansion of the enclosed air caused considerable difficulties. The purpose of the invention is therefore to create a collector, which can be used on the modular system, retains its properties and is safe in spite of the great temperature variations. According to the invention this problem is solved by providing a compensating space in the collector, which is separated by a diaphragm from the airspace between the plate and the covering window. The airspace therefore remains sealed against the atmosphere, so that no dirt, corrosion of the inside and no condensation can reduce the efficiency of the collector. A rise in pressure due to an increase in temperature is immediately reduced by expansion of the diaphragm, which enters the compensation space. In order to increase the pressure in the airspace above the plate for increases in temperature, the compensation space is connected to the atmosphere. The diaphragm can be mirrored on the side towards the absorber, which makes the diaphragm into an insulating element, as it reflects radiated heat from the absorber.

  5. Scaling laws for mode lockings in circle maps

    International Nuclear Information System (INIS)

    Cvitanovic, P.; Shraiman, B.; Soederberg, B.

    1985-06-01

    The self-similar structure of mode lockings for circle maps is studied by means of the associated Farey trees. We investigate numerically several classes of scaling relations implicit in the Farey organization of mode lockings and discuss the extent to which they lead to universal scaling laws. (orig.)

  6. 30 CFR 57.12068 - Locking transformer enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  7. Investigation on Locking and Pulling Modes in Analog Frequency Dividers

    Directory of Open Access Journals (Sweden)

    Antonio Buonomo

    2013-01-01

    Full Text Available We compare the main analytical results available to estimate the locking range, which is the key figure-of-merit of LC frequency dividers based on the injection locking phenomenon. Starting from the classical result by Adler concerning injection-locked oscillators, we elucidate the merits and the shortcomings of the different approaches to study injection-locked frequency dividers, with particular emphasis on divider-by-2. In particular, we show the potential of a perturbation approach which enables a more complete analysis of frequency dividers, making it possible to calculate not only the amplitude and the phase of the locked oscillation, but also the region where it exists and is stable, which defines the locking region. Finally, we analyze the dynamical behaviour of the dividers in the vicinity of the boundary of the locking region, showing that there exists a border region where the occurrence of the locking or the pulling operation mode is possible, depending on the initial conditions of the system.

  8. Lock-In Agreements in Venture Capital Backed UK IPOs

    NARCIS (Netherlands)

    Espenlaub, S.; Goergen, M.; Khurshed, A.; Renneboog, L.D.R.

    2002-01-01

    This paper examines the impact of venture-capital backing of UK companies issuing shares at flotation on the characteristics of the lock-in agreements entered into by the existing shareholders, and on the abnormal returns realised around the expiry of the directors' lock-in agreements.The study

  9. Aktuaalsetest tendentsidest elektroakustilise muusika alal Eestis / Gerhard Lock

    Index Scriptorium Estoniae

    Lock, Gerhard, 1978-

    2007-01-01

    Elektroakustilise muusika lähiajaloost, elektroakustilist muusikat viljelevatest Eesti heliloojatest. Age Hirv, Raun Juurikas, Liis Jürgens, Andrus Kallastu, Tatjana Kozlova, Ülo Krigul, Margo Kõlar, Märt-Matis Lill, Gerhard Lock, Hans-Gunter Lock, Malle Maltis, Jüri Reinvere, Mart Siimer, Mirjam Tally, Toomas Trass, Lauri-Dag Tüür oma muusikast

  10. Phase-locking regimes of photonic crystal nanocavity laser arrays

    DEFF Research Database (Denmark)

    Skovgård, Troels Suhr; Kristensen, Philip Trøst; Mørk, Jesper

    2011-01-01

    -difference time-domain calculations, the typical coupling strength is extracted for realistic structures. Phase-locking regimes are identified, and their stability with respect to parameter variation is investigated. The results suggest that quantum well devices are not well suited for phase-locked nanocavity...

  11. ELB-trees - Efficient Lock-free B+trees

    DEFF Research Database (Denmark)

    Bonnichsen, Lars Frydendal; Karlsson, Sven; Probst, Christian W.

    2014-01-01

    As computer systems scale in the number of processors, data structures with good parallel performance become increasingly important. Lock-free data structures promise improved parallel performance at the expense of higher complexity and sequential execution time.We present ELBtrees, a new lock-fr...

  12. Surgical treatment of proximal humerus fractures using PHILOS plate

    Directory of Open Access Journals (Sweden)

    Vijay Sharma

    2014-10-01

    Full Text Available 【Abstract】Objective: To evaluate functional outcome and complications of open reduction and internal fixation with proximal humeral internal locking system (PHILOS plate for proximal humerus fractures. Methods: We reviewed 51 patients who underwent open reduction and internal fixation with PHILOS plate between the years 2007 to 2012. There were 35 men and 16 women with a mean age of 38 years (range 24-68. There were 41 patients in the age group of <60 years and 10 patients in the age group of >60 years. According to Neer classification system, 8, 15 and 23 patients had 2-part, 3-part, and 4-part fractures, respectively and 5 patients had 4-part fracture dislocation. All surgeries were carried out at our tertiary care trauma centre. Functional evaluation of the shoulder at final follow-up was done using Constant-Murley score. Results: The mean follow-up period was 30 months (range 12-44 months. Two patients were lost to followup. Of the remaining 49 patients, all fractures were united clinically and radiologically. The mean time for radiological union was 12 weeks (range 8-20 weeks. At the final follow-up the mean Constant-Murley score was 79 (range 50-100. The results were excellent in 25 patients, good in 13 patients, fair in 6 atients and poor in 5 patients. During the follow-up, four cases of varus malunion, one case of subacromial impingement, one case of deep infection, one case of intraarticular screw penetration and one case of failure of fi xation were noted. No cases of avascular necrosis, hardware failure, locking screw loosening or nonunion were noted. Conclusion: PHILOS provides stable fixation in proximal humerus fractures. To prevent potential complications like avascular necrosis, meticulous surgical dissection to preserve vascularity of humeral head is necessary. Key words: Proximal humerus fracture; Fracture fixation, internal; Proximal humeral internal locking system

  13. Using the Vertical Component of the Surface Velocity Field to Map the Locked Zone at Cascadia Subduction Zone

    Science.gov (United States)

    Moulas, E.; Brandon, M. T.; Podladchikov, Y.; Bennett, R. A.

    2014-12-01

    At present, our understanding of the locked zone at Cascadia subduction zone is based on thermal modeling and elastic modeling of horizontal GPS velocities. The thermal model by Hyndman and Wang (1995) provided a first-order assessment of where the subduction thrust might be cold enough for stick-slip behavior. The alternative approach by McCaffrey et al. (2007) is to use a Green's function that relates horizontal surface velocities, as recorded by GPS, to interseismic elastic deformation. The thermal modeling approach is limited by a lack of information about the amount of frictional heating occurring on the thrust (Molnar and England, 1990). The GPS approach is limited in that the horizontal velocity component is fairly insensitive to the structure of the locked zone. The vertical velocity component is much more useful for this purpose. We are fortunate in that vertical velocities can now be measured by GPS to a precision of about 0.2 mm/a. The dislocation model predicts that vertical velocities should range up to about 20 percent of the subduction velocity, which means maximum values of ~7 mm/a. The locked zone is generally entirely offshore at Cascadia, except for the Olympic Peninsula region, where the underlying Juan De Fuca plate has an anomalously low dip. Previous thermal and GPS modeling, as well as tide gauge data and episodic tremors indicate the locked zone there extends about 50 to 75 km onland. This situation provides an opportunity to directly study the locked zone. With that objective in mind, we have constructed a full 3D geodynamic model of the Cascadia subduction zone. At present, the model provides a full representation of the interseismic elastic deformation due to variations of slip on the subduction thrust. The model has been benchmarked against the Savage (2D) and Okada (3D) analytical solutions. This model has an important advantage over traditional dislocation modeling in that we include temperature-sensitive viscosity for the upper and

  14. Phase locking of vortex cores in two coupled magnetic nanopillars

    Directory of Open Access Journals (Sweden)

    Qiyuan Zhu

    2014-11-01

    Full Text Available Phase locking dynamics of the coupled vortex cores in two identical magnetic spin valves induced by spin-polarized current are studied by means of micromagnetic simulations. Our results show that the available current range of phase locking can be expanded significantly by the use of constrained polarizer, and the vortices undergo large orbit motions outside the polarization areas. The effects of polarization areas and dipolar interaction on the phase locking dynamics are studied systematically. Phase locking parameters extracted from simulations are discussed by theoreticians. The dynamics of vortices influenced by spin valve geometry and vortex chirality are discussed at last. This work provides deeper insights into the dynamics of phase locking and the results are important for the design of spin-torque nano-oscillators.

  15. Spatially resolved detection of mutually locked Josephson junctions in arrays

    International Nuclear Information System (INIS)

    Keck, M.; Doderer, T.; Huebener, R.P.; Traeuble, T.; Dolata, R.; Weimann, T.; Niemeyer, J.

    1997-01-01

    Mutual locking due to the internal coupling in two-dimensional arrays of Josephson junctions was investigated. The appearance of Shapiro steps in the current versus voltage curve of a coupled on-chip detector junction is used to indicate coherent oscillations in the array. A highly coherent state is observed for some range of the array bias current. By scanning the array with a low-power electron beam, mutually locked junctions remain locked while the unlocked junctions generate a beam-induced additional voltage drop at the array. This imaging technique allows the detection of the nonlocked or weakly locked Josephson junctions in a (partially) locked array state. copyright 1997 American Institute of Physics

  16. Monolithic Hybrid and Passive Mode-Locked 40GHz Quantum Dot Laser Diodes

    DEFF Research Database (Denmark)

    Thompson, M. G.; Larsson, David; Rae, A. R.

    2006-01-01

    For the first time hybrid and passive mode-locking jitter performance is investigated in 40GHz quantum-dot mode-locked lasers. Record low passive mode-locking jitter of 219fs is presented, along with promising hybrid mode-locking results of 124fs.......For the first time hybrid and passive mode-locking jitter performance is investigated in 40GHz quantum-dot mode-locked lasers. Record low passive mode-locking jitter of 219fs is presented, along with promising hybrid mode-locking results of 124fs....

  17. Locking of intrinsic angular momentum in collision complexes

    International Nuclear Information System (INIS)

    Berengolts, Alexander.

    1995-04-01

    A concept of locking of the intrinsic angular momentum of a fragment of a collision complex to a body-fixed axis is widely used in the description of heavy-particle dynamics. The aim of this work is to provide a semiclassical description of the locking phenomenon which occur in diatomic and three atomic collision complexes. The first part of this work is devoted to the semiclassical study of the locking of the electronic angular momentum that occurs in slow collisions of two atoms, one in the spherically symmetric state and the other in state with j= 1. Here we calculate explicitly the complete locking matrix for different types of interatomic interactions. The elements of this matrix directly enter into the semiclassical expression for the different cross sections of polarized atoms. Limitations to the notion of the the locking radius and slipping probability are discussed in connection with the steepness of the interaction. Numerical calculations confirm analytical result: the optimal criterion for determination of the locking radius is a condition for the accumulated phase difference between two molecular states. Analytical expressions are suggested for the locking angle and the slipping probability. Implication of the locking approximation for calculation of the quasiclassical scattering matrix is discussed. The second part considers the locking of the rotational angular momentum of a diatom in the decomposition of a triatomic complexes. We discuss here cases J = 1,2,3 and 4, but restrict ourselves to calculation of the so-called dynamic orientation of the diatomic fragment. The letter represents one of the characteristics of the locking matrix which in principle can be measured experimentally. The orientation is created as a result of the interplay between the adiabatic interaction in the atom- diatom exit channel and the rotationally non adiabatic coupling in the perturbed rotor region

  18. Heterogeneous Silicon III-V Mode-Locked Lasers

    Science.gov (United States)

    Davenport, Michael Loehrlein

    Mode-locked lasers are useful for a variety of applications, such as sensing, telecommunication, and surgical instruments. This work focuses on integrated-circuit mode-locked lasers: those that combine multiple optical and electronic functions and are manufactured together on a single chip. While this allows production at high volume and lower cost, the true potential of integration is to open applications for mode-locked laser diodes where solid state lasers cannot fit, either due to size and power consumption constraints, or where small optical or electrical paths are needed for high bandwidth. Unfortunately, most high power and highly stable mode-locked laser diode demonstrations in scientific literature are based on the Fabry-Perot resonator design, with cleaved mirrors, and are unsuitable for use in integrated circuits because of the difficulty of producing integrated Fabry-Perot cavities. We use silicon photonics and heterogeneous integration with III-V gain material to produce the most powerful and lowest noise fully integrated mode-locked laser diode in the 20 GHz frequency range. If low noise and high peak power are required, it is arguably the best performing fully integrated mode-locked laser ever demonstrated. We present the design methodology and experimental pathway to realize a fully integrated mode-locked laser diode. The construction of the device, beginning with the selection of an integration platform, and proceeding through the fabrication process to final optimization, is presented in detail. The dependence of mode-locked laser performance on a wide variety of design parameters is presented. Applications for integrated circuit mode-locked lasers are also discussed, as well as proposed methods for using integration to improve mode-locking performance to beyond the current state of the art.

  19. Shareholder Lock-In Contracts : Share Price and Trading Volume Effects at the Lock-In Expiry

    NARCIS (Netherlands)

    Angenandt, P.P.; Goergen, M.; Renneboog, L.D.R.

    2005-01-01

    This paper unveils the diversity in lock-in agreements of firms listed on the Nouveau Marche stock exchange in France.We give the main economic reasons why shareholders adopt lock-in agreements that are more stringent than legally required.We relate the abnormal returns and the abnormal volume at

  20. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  1. Malfunctioning Plastic Biliary Endoprosthesis: Percutaneous Transhepatic Balloon Pulling Technique

    Directory of Open Access Journals (Sweden)

    Umberto G. Rossi

    2013-01-01

    Full Text Available Percutaneous transhepatic removal techniques for malfunctioning plastic biliary endoprosthesis are considered safe and efficient second-line strategies, when endoscopic procedures are not feasible. We describe the percutaneous transhepatic balloon pulling technique in a patient with an unresectable malignant hilar cholangiocarcinoma.

  2. Case Report Percutaneous Dilational Tracheostomy A bed side ...

    African Journals Online (AJOL)

    Introduction: Tracheostomy is one of the most commonly performed procedures in critically ill patients. Percutaneous dilatational tracheostomy (PDT), according to ciaglias technique described in 1985, has become the most popular technique for percutaneous tracheostomy and is demonstrably as safe as surgical.

  3. Percutaneous management of tumoral biliary obstruction in children

    Energy Technology Data Exchange (ETDEWEB)

    Akinci, Devrim; Gumus, Burcak; Ozkan, Orhan S.; Ozmen, Mustafa N.; Akhan, Okan [Hacettepe School of Medicine, Department of Radiology, Sihhiye, Ankara (Turkey); Ekinci, Saniye [Hacettepe School of Medicine, Department of Paediatric Surgery, Sihhiye, Ankara (Turkey); Akcoren, Zuhal [Hacettepe School of Medicine, Department of Paediatric Pathology, Sihhiye, Ankara (Turkey); Kutluk, Tezer [Hacettepe School of Medicine, Department of Paediatric Oncology, Sihhiye, Ankara (Turkey)

    2007-10-15

    There is limited experience of percutaneous biliary interventions in children although they are safe and effective procedures. To evaluate the efficacy and safety of percutaneous management of tumoral biliary obstruction in children. Percutaneous biliary interventions were performed in eight children (six boys, two girls) with a mean age of 10.5 years (range 4-17 years). The interventions included percutaneous biliary drainage (five patients), percutaneous biliary drainage and placement of a self-expanding metallic stent (two patients), and percutaneous cholecystostomy (one patient). All patients had signs of obstructive jaundice and two had cholangitis. All procedures were successful. No procedure-related mortality was observed. Bilirubin levels returned to normal in four of the eight patients. Findings of cholangitis resolved in the two affected patients after the procedure and antibiotic treatment. Two patients underwent surgery after percutaneous biliary drainage procedures. A self-expanding metallic stent was placed in two patients with malignancy and the stents remained patent until death. Percutaneous biliary interventions can be performed safely for the management of tumoral biliary obstruction in children. (orig.)

  4. Laparoscopic-assisted percutaneous internal ring ligation in children

    African Journals Online (AJOL)

    Annals of Pediatric Surgery ... Patients and methods Laparoscopic percutaneous ligation of internal inguinal ring has been ... The mean operative time in our series was 15 (± 3) and 20 (± 5) min for bilateral cases, without anesthesia time. ... Conclusion Laparoscopic percutaneous ligation of internal inguinal ring repair of ...

  5. Prevention and treatment of complications following percutaneous nephrolithotomy

    NARCIS (Netherlands)

    Skolarikos, Andreas; de la Rosette, Jean

    2008-01-01

    PURPOSE OF REVIEW: The aim of this article is to identify classification and grading systems of percutaneous nephrolithotomy-related complications and evidence for the prevention and treatment of these complications. RECENT FINDINGS: A total complication rate of up to 83% following percutaneous

  6. Percutaneous management of tumoral biliary obstruction in children

    International Nuclear Information System (INIS)

    Akinci, Devrim; Gumus, Burcak; Ozkan, Orhan S.; Ozmen, Mustafa N.; Akhan, Okan; Ekinci, Saniye; Akcoren, Zuhal; Kutluk, Tezer

    2007-01-01

    There is limited experience of percutaneous biliary interventions in children although they are safe and effective procedures. To evaluate the efficacy and safety of percutaneous management of tumoral biliary obstruction in children. Percutaneous biliary interventions were performed in eight children (six boys, two girls) with a mean age of 10.5 years (range 4-17 years). The interventions included percutaneous biliary drainage (five patients), percutaneous biliary drainage and placement of a self-expanding metallic stent (two patients), and percutaneous cholecystostomy (one patient). All patients had signs of obstructive jaundice and two had cholangitis. All procedures were successful. No procedure-related mortality was observed. Bilirubin levels returned to normal in four of the eight patients. Findings of cholangitis resolved in the two affected patients after the procedure and antibiotic treatment. Two patients underwent surgery after percutaneous biliary drainage procedures. A self-expanding metallic stent was placed in two patients with malignancy and the stents remained patent until death. Percutaneous biliary interventions can be performed safely for the management of tumoral biliary obstruction in children. (orig.)

  7. An elevator for locked drilling pipes

    Energy Technology Data Exchange (ETDEWEB)

    Gurbanov, R.S.; Abbasov, E.M.; Ismailov, A.A.; Mamedov, Yu.S.; Safarov, A.A.

    1983-01-01

    An elevator is proposed, which includes a body with a door. To reduce the probability of gas shows in a well with high speed lowering and lifting of the column of locked drilling pipes through providing the possibility of feeding a drilling mud in this case into the mine, the elevator is equipped with a pneumatic cylinder with a two way hollow rod, on one face of which a sealing element is mounted for sealing the drilling pipe and on the other, an adapter for feeding the drilling mud. The rod is linked with the sleeve of the pneumatic cylinder, which is rigidly linked with the body with the capability of axial movement without rotation.

  8. Gapless Color-Flavor-Locked Quark Matter

    DEFF Research Database (Denmark)

    Alford, Mark; Kouvaris, Christoforos; Rajagopal, Krishna

    2004-01-01

    In neutral cold quark matter that is sufficiently dense that the strange quark mass M_s is unimportant, all nine quarks (three colors; three flavors) pair in a color-flavor locked (CFL) pattern, and all fermionic quasiparticles have a gap. We argue that as a function of decreasing quark chemical...... potential mu or increasing M_s, there is a quantum phase transition from the CFL phase to a new ``gapless CFL phase'' in which only seven quasiparticles have a gap. The transition occurs where M_s^2/mu is approximately equal to 2*Delta, with Delta the gap parameter. Gapless CFL, like CFL, leaves unbroken...... a linear combination Qtilde of electric and color charges, but it is a Qtilde-conductor with a nonzero electron density. These electrons and the gapless quark quasiparticles make the low energy effective theory of the gapless CFL phase and, consequently, its astrophysical properties are qualitatively...

  9. Dynamics of Tidally Locked, Ultrafast Rotating Atmospheres

    Science.gov (United States)

    Tan, Xianyu; Showman, Adam P.

    2017-10-01

    Tidally locked gas giants, which exhibit a novel regime of day-night thermal forcing and extreme stellar irradiation, are typically in several-day orbits, implying slow rotation and a modest role for rotation in the atmospheric circulation. Nevertheless, there exist a class of gas-giant, highly irradiated objects - brown dwarfs orbiting white dwarfs in extremely tight orbits - whose orbital and hence rotation periods are as short as 1-2 hours. Spitzer phase curves and other observations have already been obtained for this fascinating class of objects, which raise fundamental questions about the role of rotation in controlling the circulation. So far, most modeling studies have investigated rotation periods exceeding a day, as appropriate for typical hot Jupiters. In this work we investigate the dynamics of tidally locked atmospheres in shorter rotation periods down to about two hours. With increasing rotation rate (decreasing rotation period), we show that the width of the equatorial eastward jet decreases, consistent with the narrowing of wave-mean-flow interacting region due to decrease of the equatorial deformation radius. The eastward-shifted equatorial hot spot offset decreases accordingly, and the westward-shifted hot regions poleward of the equatorial jet associated with Rossby gyres become increasingly distinctive. At high latitudes, winds becomes weaker and more geostrophic. The day-night temperature contrast becomes larger due to the stronger influence of rotation. Our simulated atmospheres exhibit small-scale variability, presumably caused by shear instability. Unlike typical hot Jupiters, phase curves of fast-rotating models show an alignment of peak flux to secondary eclipse. Our results have important implications for phase curve observations of brown dwarfs orbiting white dwarfs in ultra tight orbits.

  10. A Modified Kirchhoff plate theory for Free Vibration analysis of functionally graded material plates using meshfree method

    Science.gov (United States)

    Nguyen Van Do, Vuong

    2018-04-01

    In this paper, a modified Kirchhoff theory is presented for free vibration analyses of functionally graded material (FGM) plate based on modified radial point interpolation method (RPIM). The shear deformation effects are taken account into modified theory to ignore the locking phenomenon of thin plates. Due to the proposed refined plate theory, the number of independent unknowns reduces one variable and exists with four degrees of freedom per node. The simulated free vibration results employed by the modified RPIM are compared with the other analytical solutions to verify the effectiveness and the accuracy of the developed mesh-free method. Detail parametric studies of the proposed method are then conducted including the effectiveness of thickness ratio, boundary condition and material inhomogeneity on the sample problems of square plates. Results illustrated that the modified mesh-free RPIM can effectively predict the numerical calculation as compared to the exact solutions. The obtained numerical results are indicated that the proposed method are stable and well accurate prediction to evaluate with other published analyses.

  11. Emergency percutaneous needle decompression for tension pneumoperitoneum

    Directory of Open Access Journals (Sweden)

    Körner Markus

    2011-05-01

    Full Text Available Abstract Background Tension pneumoperitoneum as a complication of iatrogenic bowel perforation during endoscopy is a dramatic condition in which intraperitoneal air under pressure causes hemodynamic and ventilatory compromise. Like tension pneumothorax, urgent intervention is required. Immediate surgical decompression though is not always possible due to the limitations of the preclinical management and sometimes to capacity constraints of medical staff and equipment in the clinic. Methods This is a retrospective analysis of cases of pneumoperitoneum and tension pneumoperitoneum due to iatrogenic bowel perforation. All patients admitted to our surgical department between January 2005 and October 2010 were included. Tension pneumoperitoneum was diagnosed in those patients presenting signs of hemodynamic and ventilatory compromise in addition to abdominal distension. Results Between January 2005 and October 2010 eleven patients with iatrogenic bowel perforation were admitted to our surgical department. The mean time between perforation and admission was 36 ± 14 hrs (range 30 min - 130 hrs, between ER admission and begin of the operation 3 hrs and 15 min ± 47 min (range 60 min - 9 hrs. Three out of eleven patients had clinical signs of tension pneumoperitoneum. In those patients emergency percutaneous needle decompression was performed with a 16G venous catheter. This improved significantly the patients' condition (stabilization of vital signs, reducing jugular vein congestion, bridging the time to the start of the operation. Conclusions Hemodynamical and respiratory compromise in addition to abdominal distension shortly after endoscopy are strongly suggestive of tension pneumoperitoneum due to iatrogenic bowel perforation. This is a rare but life threatening condition and it can be managed in a preclinical and clinical setting with emergency percutaneous needle decompression like tension pneumothorax. Emergency percutaneous decompression is no

  12. Percutaneous acetabuloplasty for metastatic acetabular lesions

    Directory of Open Access Journals (Sweden)

    Logroscino Giandomenico

    2008-05-01

    Full Text Available Abstract Background Osteolytic metastases around the acetabulum are frequent in tumour patients, and may cause intense and drug-resistant pain of the hip. These lesions also cause structural weakening of the pelvis, limping, and poor quality of life. Percutaneous acetabuloplasty is a mini-invasive procedure for the management of metastatic lesions due to carcinoma of the acetabulum performed in patients who cannot tolerate major surgery, or in patients towards whom radiotherapy had already proved ineffective. Methods We report a retrospective study in 25 such patients (30 acetabuli who were evaluated before and after percutaneous acetabuloplasty, with regard to pain, mobility of the hip joint, use of analgesics, by means of evaluation forms: Visual Analog Scale, Harris Hip Score, Western Ontario and McMaster Universities Index of Osteoarthritis (WOMAC, Eastern Cooperative Oncology Group (ECOG. The results obtained were analysed using the χ2 Test and Fisher's exact test. Significance was sent at P Results Marked clinical improvement was observed in all patients during the first six post-operative months, with gradual a worsening thereafter from deterioration of their general condition. Complete pain relief was achieved in 15 of our 25 (59% of patients, and pain reduction was achieved in the remaining 10 (41% patients. The mean duration of pain relief was 7.3 months. Pain recurred in three patients (12% between 2 weeks to 3 months. No major complications occurred. There was transient local pain in most cases, and 2 cases of venous injection of cement without clinical consequences. Conclusion Percutaneous acetabuloplasty is effective in improving the quality of life of patients with osteolytic bone tumours, even though the improvement is observed during the first 6 months only. It can be an effective aid to chemo- and radiotherapy in the management of acetabular metastases.

  13. Plate Full of Color

    Centers for Disease Control (CDC) Podcasts

    The Eagle Books are a series of four books that are brought to life by wise animal characters - Mr. Eagle, Miss Rabbit, and Coyote - who engage Rain That Dances and his young friends in the joy of physical activity, eating healthy foods, and learning from their elders about health and diabetes prevention. Plate Full of Color teaches the value of eating a variety of colorful and healthy foods.

  14. Percutaneous removal of a pacing electrode

    International Nuclear Information System (INIS)

    Hoehne, U.; Schild, H.; Hake, U.

    1989-01-01

    The large number of pace-makers introduced transvenously has resulted in increasing the number of complications, amongst which infections and dislocations are prominent. It is usually necessary to remove the electrode, which can be attempted percutaneously by using a Dormia basket, a loop or forceps. Amongst the complications of this procedure are tears to the myocardium, with the risk of pericardial tamponade, or tears of the tricuspid valve leading to tricuspid insufficiency. Consequently, thoracic surgical intervention should be available if necessary. Four successful procedures are described. (orig.) [de

  15. Osteoid osteoma: percutaneous treatment with CT guidance

    International Nuclear Information System (INIS)

    Velan, Osvaldo; Ayzaguer, Alejandro H.; Endara Bustos, Olinda; Lambertini, Roberto G.

    2004-01-01

    Purpose: The osteoid osteoma (OO) is a benign bone tumor characterized by causing severe and constant pain at night, and for that reason it requires a surgical excision. Although for years the treatment of choice has been surgery, the development of CT-guided percutaneous procedures, such as percutaneous resection with trephine (PR), and more recently the radiofrequency ablation (RF), it is possible to remove the core of the lesion and therefore relieve the symptoms in a considerably less invasive way. Material and methods: Between January 1990 and February 2004, 65 lesions in 60 patients with a presumptive diagnosis of osteoid osteoma were treated. 49 PRs and 16 RFs were performed. Of the 49 PRs, 5 required curettage and one required an ethanol injection. The procedures were guided by CT imaging under general or spinal anesthesia with 24 hr hospitalization. Tumor samples were taken for anatomical pathology analysis (AP). The absence of symptoms and late complications was verified 30 days after the procedure. Results: All lesions were accessed successfully. In 5 of them it was necessary to broaden the resection due to a possible insufficient margin. In 38 of the 65 lesions (58,5%) AP confirmed the OO diagnosis; in 6/65 (9.2%) of them AP found other specific lesions, such as enostoma (n=2), bone cyst (n=1), inclusion cyst (n=1), chondroma (n=1), and chronic osteitis (n=1), and in the rest of the cases the findings were unspecified. All patients (60/60) showed no pain within 24-48 hours of the procedure, and 5/60 (8,3%) received further treatment due to recurring symptoms. Conclusion: The percutaneous procedure has shown to be an effective technique for the treatment of OO. Compared to surgical excision, the percutaneous technique is less invasive, it requires less anesthesia and hospitalization time, and it allows an earlier return to active life. The PR is less expensive than the RF, but it requires a wider bone incision. However, both techniques are equally

  16. Percutaneous biliary drainage in patients with cholangiocarcinoma

    International Nuclear Information System (INIS)

    Mehta, A.C.; Gobel, R.J.; Rose, S.C.; Hayes, J.K.; Miller, F.J.

    1990-01-01

    This paper determines whether radiation therapy (RT) is a risk factor for infectious complications (particularly hepatic abscess formation) related to percutaneous biliary drainage (PBD). The authors retrospectively reviewed the charts of 98 consecutive patients who had undergone PBD for obstruction. In 34 patients with benign obstruction, three infectious complications occurred, none of which were hepatic abscess or fatal sepsis. In 39 patients who had malignant obstruction but did not have cholangiocarcinoma, 13 infectious complications occurred, including two hepatic abscesses and three cases of fatal sepsis. Of the 25 patients with cholangiocarcinoma, 15 underwent RT; in these 15 patients, 14 infectious complications occurred, including six hepatic abscesses and two cases of fatal sepsis

  17. Percutaneous transluminal angioplasty (PTA) after kidney transplantation

    International Nuclear Information System (INIS)

    Fava, C.; Grosso, M.; Sandrone, M.; Malfi, B.; Segoloni, G.P.; Colla, L.

    1988-01-01

    Renal artery stenosis is a frequent complication of kidney transplantation (10%). Percutaneous transluminal angioplasty (PTA) has recently been proposed as a potential therapeutic procedure. Twelve transplant patients with arterial stenosis underwent PTA. The procedure was successful in 10 cases (83.3%). Restenosis occurred in 2 patients (16.7%); both of them underwent PTA successfully. No complications occurred. A considerable improvement in glomerular filtration rate and a reduction in high blood pressure were observed in all patients after successful PTA. The authors belive PTA to be the therapy of choice in the treatment of arterial stenoses in kidney transplant patients

  18. The Use of Percutaneous Lumbar Fixation Screws for Bilateral Pedicle Fractures with an Associated Dislocation of a Lumbar Disc Prosthesis

    Directory of Open Access Journals (Sweden)

    William D. Harrison

    2013-01-01

    Full Text Available Study Design. Case report. Objective. To identify a safe technique for salvage surgery following complications of total disc replacement. Summary of Background Data. Lumbar total disc replacement (TDR is considered by some as the gold standard for discogenic back pain. Revision techniques for TDR and their complications are in their infancy. This case describes a successful method of fixation for this complex presentation. Methods and Results. A 48-year-old male with lumbar degenerative disc disease and no comorbidities. Approximately two weeks postoperatively for a TDR, the patient represented with acute severe back pain and the TDR polyethylene inlay was identified as dislocated anteriorly. Subsequent revision surgery failed immediately as the polyethylene inlay redislocated intraoperatively. Further radiology identified bilateral pedicle fractures, previously unseen on the plain films. The salvage fusion of L5/S1 reutilized the anterior approach with an interbody fusion cage and bone graft. The patient was then turned intraoperatively and redraped. The percutaneous pedicle screws were used to fix L5 to the sacral body via the paracoccygeal corridor. Conclusion. The robust locking screw in the percutaneous screw allowed a complete fixation of the pedicle fractures. At 3-year followup, the patient has an excellent result and has returned to playing golf.

  19. Effect of plate shapes in orifice plate type flowmeters

    International Nuclear Information System (INIS)

    Moeller, S.V.

    1984-01-01

    The study of unusual plate shapes in orifice plate type flowmeters is presented, with a view to providing data for the substitution of the plate with one centered circular orifice in those applications where its use is not possible. For this purpose, six pairs of plates with different forms, with and without chamfered edges, were made and tested in a closed water loop. Results show that, generally, the use of chamfers improves the results and, in the case of perforated and slotlike orificed plates, the narrow-ness of the fluid passage tends to make unnecessary its use. (Author) [pt

  20. Plate removal following orthognathic surgery.

    Science.gov (United States)

    Little, Mhairi; Langford, Richard Julian; Bhanji, Adam; Farr, David

    2015-11-01

    The objectives of this study are to determine the removal rates of orthognathic plates used during orthognathic surgery at James Cook University Hospital and describe the reasons for plate removal. 202 consecutive orthognathic cases were identified between July 2004 and July 2012. Demographics and procedure details were collected for these patients. Patients from this group who returned to theatre for plate removal between July 2004 and November 2012 were identified and their notes were analysed for data including reason for plate removal, age, smoking status, sex and time to plate removal. 3.2% of plates were removed with proportionally more plates removed from the mandible than the maxilla. 10.4% of patients required removal of one or more plate. Most plates were removed within the first post-operative year. The commonest reasons for plate removal were plate exposure and infection. The plate removal rates in our study are comparable to those seen in the literature. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.